Blood volume analysis: a new technique and new clinical interest reinvigorate a classic study.
Manzone, Timothy A; Dam, Hung Q; Soltis, Daniel; Sagar, Vidya V
2007-06-01
Blood volume studies using the indicator dilution technique and radioactive tracers have been performed in nuclear medicine departments for over 50 y. A nuclear medicine study is the gold standard for blood volume measurement, but the classic dual-isotope blood volume study is time-consuming and can be prone to technical errors. Moreover, a lack of normal values and a rubric for interpretation made volume status measurement of limited interest to most clinicians other than some hematologists. A new semiautomated system for blood volume analysis is now available and provides highly accurate results for blood volume analysis within only 90 min. The availability of rapid, accurate blood volume analysis has brought about a surge of clinical interest in using blood volume data for clinical management. Blood volume analysis, long a low-volume nuclear medicine study all but abandoned in some laboratories, is poised to enter the clinical mainstream. This article will first present the fundamental principles of fluid balance and the clinical means of volume status assessment. We will then review the indicator dilution technique and how it is used in nuclear medicine blood volume studies. We will present an overview of the new semiautomated blood volume analysis technique, showing how the study is done, how it works, what results are provided, and how those results are interpreted. Finally, we will look at some of the emerging areas in which data from blood volume analysis can improve patient care. The reader will gain an understanding of the principles underlying blood volume assessment, know how current nuclear medicine blood volume analysis studies are performed, and appreciate their potential clinical impact.
Raghav, Raj; Middleton, Rachael; BSc, Rinshiya Ahamed; Arjunan, Raji; Caliendo, Valentina
2015-12-01
Arterial and venous blood gas analysis is useful in the assessment of tissue oxygenation and ventilation and in diagnosis of metabolic and respiratory derangements. It can be performed with a relatively small volume of blood in avian patients under emergency situations. Arterial and venous blood gas analysis was performed in 30 healthy gyr falcons ( Falco rusticolus ) under anaesthesia to establish temperature-corrected reference intervals for arterial blood gas values and to compare them to temperature-corrected venous blood gas values with a portable point-of-care blood gas analyzer (i-STAT 1, Abbott Laboratories, Abbott Park, IL, USA). Statistically significant differences were observed between the temperature-corrected values of pH, partial pressure of carbon dioxide (Pco2), and partial pressure of oxygen (Po2) and the corresponding nontemperature-corrected values of these parameters in both arterial and venous blood. Values of temperature-corrected pH, temperature-corrected Pco2, bicarbonate concentrations, and base excess of extra cellular fluid did not differ significantly between arterial and venous blood, suggesting that, in anesthetized gyr falcons, venous blood gas analysis can be used in place of arterial blood gas analysis in clinical situations. Values for hematocrit, measured by the point-of-care analyzer, were significantly lower compared with those obtained by the microhematocrit method.
Detection of human disease conditions by single-cell morpho-rheological phenotyping of blood.
Toepfner, Nicole; Herold, Christoph; Otto, Oliver; Rosendahl, Philipp; Jacobi, Angela; Kräter, Martin; Stächele, Julia; Menschner, Leonhard; Herbig, Maik; Ciuffreda, Laura; Ranford-Cartwright, Lisa; Grzybek, Michal; Coskun, Ünal; Reithuber, Elisabeth; Garriss, Geneviève; Mellroth, Peter; Henriques-Normark, Birgitta; Tregay, Nicola; Suttorp, Meinolf; Bornhäuser, Martin; Chilvers, Edwin R; Berner, Reinhard; Guck, Jochen
2018-01-13
Blood is arguably the most important bodily fluid and its analysis provides crucial health status information. A first routine measure to narrow down diagnosis in clinical practice is the differential blood count, determining the frequency of all major blood cells. What is lacking to advance initial blood diagnostics is an unbiased and quick functional assessment of blood that can narrow down the diagnosis and generate specific hypotheses. To address this need, we introduce the continuous, cell-by-cell morpho-rheological (MORE) analysis of diluted whole blood, without labeling, enrichment or separation, at rates of 1000 cells/sec. In a drop of blood we can identify all major blood cells and characterize their pathological changes in several disease conditions in vitro and in patient samples. This approach takes previous results of mechanical studies on specifically isolated blood cells to the level of application directly in blood and adds a functional dimension to conventional blood analysis. © 2018, Toepfner et al.
Detection of human disease conditions by single-cell morpho-rheological phenotyping of blood
Toepfner, Nicole; Herold, Christoph; Otto, Oliver; Rosendahl, Philipp; Jacobi, Angela; Kräter, Martin; Stächele, Julia; Menschner, Leonhard; Herbig, Maik; Ciuffreda, Laura; Ranford-Cartwright, Lisa; Grzybek, Michal; Coskun, Ünal; Reithuber, Elisabeth; Garriss, Geneviève; Mellroth, Peter; Henriques-Normark, Birgitta; Tregay, Nicola; Suttorp, Meinolf; Bornhäuser, Martin; Chilvers, Edwin R; Berner, Reinhard
2018-01-01
Blood is arguably the most important bodily fluid and its analysis provides crucial health status information. A first routine measure to narrow down diagnosis in clinical practice is the differential blood count, determining the frequency of all major blood cells. What is lacking to advance initial blood diagnostics is an unbiased and quick functional assessment of blood that can narrow down the diagnosis and generate specific hypotheses. To address this need, we introduce the continuous, cell-by-cell morpho-rheological (MORE) analysis of diluted whole blood, without labeling, enrichment or separation, at rates of 1000 cells/sec. In a drop of blood we can identify all major blood cells and characterize their pathological changes in several disease conditions in vitro and in patient samples. This approach takes previous results of mechanical studies on specifically isolated blood cells to the level of application directly in blood and adds a functional dimension to conventional blood analysis. PMID:29331015
Preliminary profiling of blood transcriptome in a rat model of hemorrhagic shock.
Braga, D; Barcella, M; D'Avila, F; Lupoli, S; Tagliaferri, F; Santamaria, M H; DeLano, F A; Baselli, G; Schmid-Schönbein, G W; Kistler, E B; Aletti, F; Barlassina, C
2017-08-01
Hemorrhagic shock is a leading cause of morbidity and mortality worldwide. Significant blood loss may lead to decreased blood pressure and inadequate tissue perfusion with resultant organ failure and death, even after replacement of lost blood volume. One reason for this high acuity is that the fundamental mechanisms of shock are poorly understood. Proteomic and metabolomic approaches have been used to investigate the molecular events occurring in hemorrhagic shock but, to our knowledge, a systematic analysis of the transcriptomic profile is missing. Therefore, a pilot analysis using paired-end RNA sequencing was used to identify changes that occur in the blood transcriptome of rats subjected to hemorrhagic shock after blood reinfusion. Hemorrhagic shock was induced using a Wigger's shock model. The transcriptome of whole blood from shocked animals shows modulation of genes related to inflammation and immune response (Tlr13, Il1b, Ccl6, Lgals3), antioxidant functions (Mt2A, Mt1), tissue injury and repair pathways (Gpnmb, Trim72) and lipid mediators (Alox5ap, Ltb4r, Ptger2) compared with control animals. These findings are congruent with results obtained in hemorrhagic shock analysis by other authors using metabolomics and proteomics. The analysis of blood transcriptome may be a valuable tool to understand the biological changes occurring in hemorrhagic shock and a promising approach for the identification of novel biomarkers and therapeutic targets. Impact statement This study provides the first pilot analysis of the changes occurring in transcriptome expression of whole blood in hemorrhagic shock (HS) rats. We showed that the analysis of blood transcriptome is a useful approach to investigate pathways and functional alterations in this disease condition. This pilot study encourages the possible application of transcriptome analysis in the clinical setting, for the molecular profiling of whole blood in HS patients.
Comparison of iSTAT and EPOC Blood Analyzers
2017-10-25
requires accurate blood analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared... analysis across a range of environmental conditions and, in extreme circumstances, use beyond the expiration date. We compared gold standard laboratory...temperatures for either device can result in spurious results, particularly for blood gases. 2.0 BACKGROUND Blood analysis is a critical aspect of
Independent Prognostic Factors for Acute Organophosphorus Pesticide Poisoning.
Tang, Weidong; Ruan, Feng; Chen, Qi; Chen, Suping; Shao, Xuebo; Gao, Jianbo; Zhang, Mao
2016-07-01
Acute organophosphorus pesticide poisoning (AOPP) is becoming a significant problem and a potential cause of human mortality because of the abuse of organophosphate compounds. This study aims to determine the independent prognostic factors of AOPP by using multivariate logistic regression analysis. The clinical data for 71 subjects with AOPP admitted to our hospital were retrospectively analyzed. This information included the Acute Physiology and Chronic Health Evaluation II (APACHE II) scores, 6-h post-admission blood lactate levels, post-admission 6-h lactate clearance rates, admission blood cholinesterase levels, 6-h post-admission blood cholinesterase levels, cholinesterase activity, blood pH, and other factors. Univariate analysis and multivariate logistic regression analyses were conducted to identify all prognostic factors and independent prognostic factors, respectively. A receiver operating characteristic curve was plotted to analyze the testing power of independent prognostic factors. Twelve of 71 subjects died. Admission blood lactate levels, 6-h post-admission blood lactate levels, post-admission 6-h lactate clearance rates, blood pH, and APACHE II scores were identified as prognostic factors for AOPP according to the univariate analysis, whereas only 6-h post-admission blood lactate levels, post-admission 6-h lactate clearance rates, and blood pH were independent prognostic factors identified by multivariate logistic regression analysis. The receiver operating characteristic analysis suggested that post-admission 6-h lactate clearance rates were of moderate diagnostic value. High 6-h post-admission blood lactate levels, low blood pH, and low post-admission 6-h lactate clearance rates were independent prognostic factors identified by multivariate logistic regression analysis. Copyright © 2016 by Daedalus Enterprises.
... Blood ammonia levels Blood chemistry ( chem-20 ) Blood gas analysis Cerebrospinal fluid (CSF) analysis Drug or alcohol ... these drugs may be small Control problems with behavior, such as loss of judgment or confusion Someone ...
Leeman, Mats; Choi, Jaeyeong; Hansson, Sebastian; Storm, Matilda Ulmius; Nilsson, Lars
2018-05-29
The analysis of aggregates of therapeutic proteins is crucial in order to ensure efficacy and patient safety. Typically, the analysis is performed in the finished formulation to ensure that aggregates are not present. An important question is, however, what happens to therapeutic proteins, with regard to oligomerization and aggregation, after they have been administrated (i.e., in the blood). In this paper, the separation of whole blood, plasma, and serum is shown using asymmetric flow field-flow fractionation (AF4) with a minimum of sample pre-treatment. Furthermore, the analysis and size characterization of a fluorescent antibody in blood plasma using AF4 are demonstrated. The results show the suitability and strength of AF4 for blood analysis and open new important routes for the analysis and characterization of therapeutic proteins in the blood.
... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... osmotic gap, tests for blood sodium, blood urea nitrogen (BUN) , and glucose must be performed to calculate ...
A rational framework for production decision making in blood establishments.
Ramoa, Augusto; Maia, Salomé; Lourenço, Anália
2012-07-24
SAD_BaSe is a blood bank data analysis software, created to assist in the management of blood donations and the blood production chain in blood establishments. In particular, the system keeps track of several collection and production indicators, enables the definition of collection and production strategies, and the measurement of quality indicators required by the Quality Management System regulating the general operation of blood establishments. This paper describes the general scenario of blood establishments and its main requirements in terms of data management and analysis. It presents the architecture of SAD_BaSe and identifies its main contributions. Specifically, it brings forward the generation of customized reports driven by decision making needs and the use of data mining techniques in the analysis of donor suspensions and donation discards.
A Rational Framework for Production Decision Making in Blood Establishments.
Ramoa, Augusto; Maia, Salomé; Lourenço, Anália
2012-12-01
SAD_BaSe is a blood bank data analysis software, created to assist in the management of blood donations and the blood production chain in blood establishments. In particular, the system keeps track of several collection and production indicators, enables the definition of collection and production strategies, and the measurement of quality indicators required by the Quality Management System regulating the general operation of blood establishments. This paper describes the general scenario of blood establishments and its main requirements in terms of data management and analysis. It presents the architecture of SAD_BaSe and identifies its main contributions. Specifically, it brings forward the generation of customized reports driven by decision making needs and the use of data mining techniques in the analysis of donor suspensions and donation discards.
Preliminary profiling of blood transcriptome in a rat model of hemorrhagic shock
Braga, D; Barcella, M; D’Avila, F; Lupoli, S; Tagliaferri, F; Santamaria, MH; DeLano, FA; Baselli, G; Schmid-Schönbein, GW; Kistler, EB; Aletti, F
2017-01-01
Hemorrhagic shock is a leading cause of morbidity and mortality worldwide. Significant blood loss may lead to decreased blood pressure and inadequate tissue perfusion with resultant organ failure and death, even after replacement of lost blood volume. One reason for this high acuity is that the fundamental mechanisms of shock are poorly understood. Proteomic and metabolomic approaches have been used to investigate the molecular events occurring in hemorrhagic shock but, to our knowledge, a systematic analysis of the transcriptomic profile is missing. Therefore, a pilot analysis using paired-end RNA sequencing was used to identify changes that occur in the blood transcriptome of rats subjected to hemorrhagic shock after blood reinfusion. Hemorrhagic shock was induced using a Wigger’s shock model. The transcriptome of whole blood from shocked animals shows modulation of genes related to inflammation and immune response (Tlr13, Il1b, Ccl6, Lgals3), antioxidant functions (Mt2A, Mt1), tissue injury and repair pathways (Gpnmb, Trim72) and lipid mediators (Alox5ap, Ltb4r, Ptger2) compared with control animals. These findings are congruent with results obtained in hemorrhagic shock analysis by other authors using metabolomics and proteomics. The analysis of blood transcriptome may be a valuable tool to understand the biological changes occurring in hemorrhagic shock and a promising approach for the identification of novel biomarkers and therapeutic targets. Impact statement This study provides the first pilot analysis of the changes occurring in transcriptome expression of whole blood in hemorrhagic shock (HS) rats. We showed that the analysis of blood transcriptome is a useful approach to investigate pathways and functional alterations in this disease condition. This pilot study encourages the possible application of transcriptome analysis in the clinical setting, for the molecular profiling of whole blood in HS patients. PMID:28661205
Speckle-correlation analysis of the microcapillary blood circulation in nail bed
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vilenskii, M A; Agafonov, D N; Zimnyakov, D A
2011-04-30
We present the results of the experimental studies of the possibility of monitoring the blood microcirculation in human finger nail bed with application of speckle-correlation analysis, based on estimating the contrast of time-averaged dynamic speckles. The hemodynamics at normal blood circulation and under conditions of partially suppressed blood circulation is analysed. A microscopic analysis is performed to visualise the structural changes in capillaries that are caused by suppressing blood circulation. The problems and prospects of speckle-correlation monitoring of the nail bed microhemodynamics under laboratory and clinical conditions are discussed. (optical technologies in biophysics and medicine)
Smartphone-based assessment of blood alteration severity
NASA Astrophysics Data System (ADS)
Li, Xianglin; Xue, Jiaxin; Li, Wei; Li, Ting
2018-02-01
Blood quality and safety management is a critical issue for cold chain transportation of blood or blood-based biological reagent. The conventional methods of blood alteration severity assessment mainly rely on kit test or blood-gas analysis required opening the blood package to get samples, which cause possible blood pollution and are complicate, timeconsuming, and expensive. Here we proposed to develop a portable, real-time, safety, easy-operated and low cost method aimed at assessing blood alteration severity. Color images of the blood in transparent blood bags were collected with a smartphone and the alteration severity of the blood was assessed by the smartphone app offered analysis of RGB color values of the blood. The algorithm is based on a large number sample of RGB values of blood at different alteration degree. The blood quality results evaluated by the smartphone are in accordance with the actual data. This study indicates the potential of smart phone in real time, convenient, and reliable blood quality assessment.
Lu, Yong Ping; Tsuprykov, Oleg; Vignon-Zellweger, Nicolas; Heiden, Susi; Hocher, Berthold
2016-01-01
ET-1 has independent effects on blood pressure regulation in vivo, it is involved in tubular water and salt excretion, promotes constriction of smooth muscle cells, modulates sympathetic nerve activity, and activates the liberation of nitric oxide. To determine the net effect of these partially counteracting mechanisms on blood pressure, a systematic meta-analysis was performed. Based on the principles of Cochrane systematic reviews, we searched in major literature databases - MEDLINE (PubMed), Embase, Google Scholar, and the China Biological Medicine Database (CBM-disc) - for articles relevant to the topic of the blood pressure phenotype of endothelin-1 transgenic (ET-1+/+) mice from January 1, 1988 to March 31, 2016. Review Manager Version 5.0 (Rev-Man 5.0) software was applied for statistical analysis. In total thirteen studies reported blood pressure data. The meta-analysis of blood pressure data showed that homozygous ET-1 transgenic mice (ET-1+/+ mice) had a significantly lower blood pressure as compared to WT mice (mean difference: -2.57 mmHg, 95% CI: -4.98∼ -0.16, P = 0.04), with minimal heterogeneity (P = 0.86). A subgroup analysis of mice older than 6 months revealed that the blood pressure difference between ET-1+/+ mice and WT mice was even more pronounced (mean difference: -6.19 mmHg, 95% CI: -10.76∼ -1.62, P = 0.008), with minimal heterogeneity (P = 0.91). This meta-analysis provides robust evidence that global ET-1 overexpression in mice lowers blood pressure in an age-dependent manner. Older ET-1+/+ mice have a somewhat more pronounced reduction of blood pressure. © 2016 The Author(s) Published by S. Karger AG, Basel.
Image-derived input function with factor analysis and a-priori information.
Simončič, Urban; Zanotti-Fregonara, Paolo
2015-02-01
Quantitative PET studies often require the cumbersome and invasive procedure of arterial cannulation to measure the input function. This study sought to minimize the number of necessary blood samples by developing a factor-analysis-based image-derived input function (IDIF) methodology for dynamic PET brain studies. IDIF estimation was performed as follows: (a) carotid and background regions were segmented manually on an early PET time frame; (b) blood-weighted and tissue-weighted time-activity curves (TACs) were extracted with factor analysis; (c) factor analysis results were denoised and scaled using the voxels with the highest blood signal; (d) using population data and one blood sample at 40 min, whole-blood TAC was estimated from postprocessed factor analysis results; and (e) the parent concentration was finally estimated by correcting the whole-blood curve with measured radiometabolite concentrations. The methodology was tested using data from 10 healthy individuals imaged with [(11)C](R)-rolipram. The accuracy of IDIFs was assessed against full arterial sampling by comparing the area under the curve of the input functions and by calculating the total distribution volume (VT). The shape of the image-derived whole-blood TAC matched the reference arterial curves well, and the whole-blood area under the curves were accurately estimated (mean error 1.0±4.3%). The relative Logan-V(T) error was -4.1±6.4%. Compartmental modeling and spectral analysis gave less accurate V(T) results compared with Logan. A factor-analysis-based IDIF for [(11)C](R)-rolipram brain PET studies that relies on a single blood sample and population data can be used for accurate quantification of Logan-V(T) values.
Clinical Utility of Blood Cell Histogram Interpretation
Bhagya, S.; Majeed, Abdul
2017-01-01
An automated haematology analyser provides blood cell histograms by plotting the sizes of different blood cells on X-axis and their relative number on Y-axis. Histogram interpretation needs careful analysis of Red Blood Cell (RBC), White Blood Cell (WBC) and platelet distribution curves. Histogram analysis is often a neglected part of the automated haemogram which if interpreted well, has significant potential to provide diagnostically relevant information even before higher level investigations are ordered. PMID:29207767
Clinical Utility of Blood Cell Histogram Interpretation.
Thomas, E T Arun; Bhagya, S; Majeed, Abdul
2017-09-01
An automated haematology analyser provides blood cell histograms by plotting the sizes of different blood cells on X-axis and their relative number on Y-axis. Histogram interpretation needs careful analysis of Red Blood Cell (RBC), White Blood Cell (WBC) and platelet distribution curves. Histogram analysis is often a neglected part of the automated haemogram which if interpreted well, has significant potential to provide diagnostically relevant information even before higher level investigations are ordered.
Using Willie's Acid-Base Box for Blood Gas Analysis
ERIC Educational Resources Information Center
Dietz, John R.
2011-01-01
In this article, the author describes a method developed by Dr. William T. Lipscomb for teaching blood gas analysis of acid-base status and provides three examples using Willie's acid-base box. Willie's acid-base box is constructed using three of the parameters of standard arterial blood gas analysis: (1) pH; (2) bicarbonate; and (3) CO[subscript…
Analysis of the Magnetic Field Influence on the Rheological Properties of Healthy Persons Blood
Nawrocka-Bogusz, Honorata
2013-01-01
The influence of magnetic field on whole blood rheological properties remains a weakly known phenomenon. An in vitro analysis of the magnetic field influence on the rheological properties of healthy persons blood is presented in this work. The study was performed on blood samples taken from 25 healthy nonsmoking persons and included comparative analysis of the results of both the standard rotary method (flow curve measurement) and the oscillatory method known also as the mechanical dynamic analysis, performed before and after exposition of blood samples to magnetic field. The principle of the oscillatory technique lies in determining the amplitude and phase of the oscillations of the studied sample subjected to action of a harmonic force of controlled amplitude and frequency. The flow curve measurement involved determining the shear rate dependence of blood viscosity. The viscoelastic properties of the blood samples were analyzed in terms of complex blood viscosity. All the measurements have been performed by means of the Contraves LS40 rheometer. The data obtained from the flow curve measurements complemented by hematocrit and plasma viscosity measurements have been analyzed using the rheological model of Quemada. No significant changes of the studied rheological parameters have been found. PMID:24078918
Calculation and analysis of velocity and viscous drag in an artery with a periodic pressure gradient
NASA Astrophysics Data System (ADS)
Alizadeh, M.; Seyedpour, S. M.; Mozafari, V.; Babazadeh, Shayan S.
2012-07-01
Blood as a fluid that human and other living creatures are dependent on has been always considered by scientists and researchers. Any changes in blood pressure and its normal velocity can be a sign of a disease. Whatever significant in blood fluid's mechanics is Constitutive equations and finding some relations for analysis and description of drag, velocity and periodic blood pressure in vessels. In this paper, by considering available experimental quantities, for blood pressure and velocity in periodic time of a thigh artery of a living dog, at first it is written into Fourier series, then by solving Navier-Stokes equations, a relation for curve drawing of vessel blood pressure with rigid wall is obtained. Likewise in another part of this paper, vessel wall is taken in to consideration that vessel wall is elastic and its pressure and velocity are written into complex Fourier series. In this case, by solving Navier-Stokes equations, some relations for blood velocity, viscous drag on vessel wall and blood pressure are obtained. In this study by noting that vessel diameter is almost is large (3.7 mm), and blood is considered as a Newtonian fluid. Finally, available experimental quantities of pressure with obtained curve of solving Navier-Stokes equations are compared. In blood analysis in rigid vessel, existence of 48% variance in pressure curve systole peak caused vessel blood flow analysis with elastic wall, results in new relations for blood flow description. The Resultant curve is obtained from new relations holding 10% variance in systole peak.
Voss, Sven Christian; Jaganjac, Morana; Al-Thani, Amna Mohamed; Grivel, Jean-Charles; Raynaud, Christophe Michel; Al-Jaber, Hind; Al-Menhali, Afnan Saleh; Merenkov, Zeyed Ahmad; Alsayrafi, Mohammed; Latiff, Aishah; Georgakopoulos, Costas
2017-11-01
Blood doping in sports is prohibited by the World Anti-Doping Agency (WADA). To find a possible biomarker for the detection of blood doping, we investigated the changes in blood stored in CPDA-1 blood bags of eight healthy subjects who donated one unit of blood. Aliquots were taken on days 0, 14, and 35. Platelet-free plasma was prepared and stored at -80°C until analysis on a flow cytometer dedicated for the analysis of microparticles (MPs). Changes in the number of red blood cell (RBC) -MPs were highly significant (p < 0.0001) with a mean of 219 (10^3/μL) on day 0 changing to 23 120 (10^3/μL) on day 14 and 29 310 (10^3/μL) on day 35. We conclude that RBC-MPs seem to be a promising biomarker for doping control but confirmation by a transfusion study is necessary. Copyright © 2017 John Wiley & Sons, Ltd.
High Blood Pressure and Kidney Disease
... Kidney disease is diagnosed with urine and blood tests . Health care providers measure blood pressure with a blood pressure ... the sample to a lab for analysis. A health care provider may order a blood test to estimate how much blood the kidneys filter ...
Blood creatinine level in postmortem cases.
Nishida, Atsushi; Funaki, Hironao; Kobayashi, Masaki; Tanaka, Yuka; Akasaka, Yoshihisa; Kubo, Toshikazu; Ikegaya, Hiroshi
2015-05-01
Blood chemical analysis for the diagnosis of diseases in forensic cases should be conducted in the same way as for clinical cases. However, it is sometimes difficult to obtain serum samples in forensic cases because of postmortem changes such as hemolysis and putrefaction. This study aimed to evaluate renal function in postmortem cases by blood creatinine analysis. The blood creatinine level was measured by high performance liquid chromatography (HPLC) using whole blood samples taken from 77 postmortem cases, and the relationships between blood creatinine level, postmortem interval, and cause of death were examined. The median blood creatinine level was found to be 1.15 mg/dL, with no significant differences between blood samples taken from different parts of the body. The blood creatinine level was stable for 3 days after death and gradually increased after that period, in line with a previous study using enzymatic analysis that found the serum creatinine level was stable in the early postmortem period. The blood creatinine level was high in the cases of blunt injury, intoxication, and in deaths caused by fire. This was considered to reflect acute renal dysfunction. However, the postmortem blood creatinine level remained higher than the clinical normal value despite omitting cases with renal dysfunction from the analysis. Therefore, we next investigated the change in postmortem creatinine levels in mice and found that the blood creatinine level increased with the emergence of rigor mortis. Our findings indicate that HPLC is useful in the postmortem evaluation of renal function even in the cases where serum cannot be obtained. However, the presence of rigor mortis should be considered in the evaluation of blood creatinine values. Copyright © 2014 Forensic Science Society. Published by Elsevier Ireland Ltd. All rights reserved.
Fujihara, J; Fujita, Y; Yamamoto, T; Nishimoto, N; Kimura-Kataoka, K; Kurata, S; Takinami, Y; Yasuda, T; Takeshita, H
2017-03-01
Raman spectroscopy is commonly used in chemistry to identify molecular structure. This technique is a nondestructive analysis and needs no sample preparation. Recently, Raman spectroscopy has been shown to be effective as a multipurpose analytical method for forensic applications. In the present study, blood identification and discrimination between human and nonhuman blood were performed by a portable Raman spectrometer, which can be used at a crime scene. To identify the blood and to discriminate between human and nonhuman blood, Raman spectra of bloodstains from 11 species (human, rat, mouse, cow, horse, sheep, pig, rabbit, cat, dog, and chicken) were taken using a portable Raman spectrometer. Raman peaks for blood (742, 1001, 1123, 1247, 1341, 1368, 1446, 1576, and 1619 cm -1 ) could be observed by the portable Raman spectrometer in all 11 species, and the human bloodstain could be distinguished from the nonhuman ones by using a principal component analysis. This analysis can be performed on a bloodstain sample of at least 3 months old. The portable Raman spectrometer can be used at a crime scene, and this analysis is useful for forensic examination.
FloWave.US: validated, open-source, and flexible software for ultrasound blood flow analysis.
Coolbaugh, Crystal L; Bush, Emily C; Caskey, Charles F; Damon, Bruce M; Towse, Theodore F
2016-10-01
Automated software improves the accuracy and reliability of blood velocity, vessel diameter, blood flow, and shear rate ultrasound measurements, but existing software offers limited flexibility to customize and validate analyses. We developed FloWave.US-open-source software to automate ultrasound blood flow analysis-and demonstrated the validity of its blood velocity (aggregate relative error, 4.32%) and vessel diameter (0.31%) measures with a skeletal muscle ultrasound flow phantom. Compared with a commercial, manual analysis software program, FloWave.US produced equivalent in vivo cardiac cycle time-averaged mean (TAMean) velocities at rest and following a 10-s muscle contraction (mean bias <1 pixel for both conditions). Automated analysis of ultrasound blood flow data was 9.8 times faster than the manual method. Finally, a case study of a lower extremity muscle contraction experiment highlighted the ability of FloWave.US to measure small fluctuations in TAMean velocity, vessel diameter, and mean blood flow at specific time points in the cardiac cycle. In summary, the collective features of our newly designed software-accuracy, reliability, reduced processing time, cost-effectiveness, and flexibility-offer advantages over existing proprietary options. Further, public distribution of FloWave.US allows researchers to easily access and customize code to adapt ultrasound blood flow analysis to a variety of vascular physiology applications. Copyright © 2016 the American Physiological Society.
Institutional Knots: A Comparative Analysis of Cord Blood Policy in Canada and the United States.
Denburg, Avram
2016-02-01
Umbilical cord blood is a rich source of blood stem cells, which are of critical clinical importance in the treatment of a variety of malignant and genetic conditions requiring stem cell transplantation. Many countries have established national public cord blood banks; such banks often coexist with a panoply of private options for cord blood banking. Until recently, Canada was the only G8 country without a national cord blood bank. This differs markedly from the United States, which years ago established a national cord blood bank policy and inventory. This article investigates potential reasons for this discrepancy through a comparative analysis of the evolution of programs and policies on national cord blood banking in Canada and the United States. My analysis suggests that cross-national discrepancies in policy on public cord blood banking were determined primarily by institutional factors, principal among them formal governmental structure and the legacy of past policies. Institutional entrepreneurialism in the health sector played a constitutive role in the earlier evolution of national cord blood policy in the United States as compared to Canada. Copyright © 2016 by Duke University Press.
Qu, Cheng; Tang, Yu-Ping; Shi, Xu-Qin; Zhou, Gui-Sheng; Shang, Er-Xin; Shang, Li-Li; Guo, Jian-Ming; Liu, Pei; Zhao, Jing; Zhao, Bu-Chang; Duan, Jin-Ao
2017-08-01
To evaluate the promoting blood circulation and removing blood stasis effects of Danshen-Honghua(DH) herb pair with different preparations (alcohol, 50% alcohol and water) on blood rheology and coagulation functions in acute blood stasis rats, and optimize the best preparation method of DH based on principal component analysis(PCA), hierarchical cluster heatmap analysis and multi-attribute comprehensive index methods. Ice water bath and subcutaneous injection of adrenaline were both used to establish the acute blood stasis rat model. Then the blood stasis rats were administrated intragastrically with DH (alcohol, 50% alcohol and water) extracts. The whole blood viscosity(WBV), plasma viscosity(PV), erythrocyte sedimentation rate(ESR) and haematocrit(HCT) were tested to observe the effects of DH herb pair with different preparations and doses on hemorheology of blood stasis rats; the activated partial thromboplastin time(APTT), thrombin time(TT), prothrombin time(PT), and plasma fibrinogen(FIB) were tested to observe the effects of DH herb pair with different preparations on blood coagulation function and platelet aggregation of blood stasis rats. Then PCA, hierarchical cluster heatmap analysis and multi-attribute comprehensive index methods were all used to comprehensively evaluate the total promoting blood circulation and removing blood stasis effects of DH herb pair with different preparations. The hemorheological indexes and coagulation parameters of model group had significant differences with normal blank group. As compared with the model group, the DH herb pair with different preparations at low, middle and high doses could improve the blood hemorheology indexes and coagulation parameters in acute blood stasis rats with dose-effect relation. Based on the PCA, hierarchical cluster heatmap analysis and multi-attribute comprehensive index methods, the high dose group of 50% alcohol extract had the best effect of promoting blood circulation and removing blood stasis. Under the same dose but different preparations, 50% alcohol DH could obviously improve the hemorheology and blood coagulation function in acute blood stasis rats. These results suggested that DH herb pair with different preparations could obviously ameliorate the abnormality of hemorheology and blood coagulation function in acute blood stasis rats, and the optimized preparation of DH herb pair on promoting blood effects was 50% alcohol extract, providing scientific basis for more effective application of the DH herb pair in modern clinic medicine. Copyright© by the Chinese Pharmaceutical Association.
[Blood sampling using "dried blood spot": a clinical biology revolution underway?].
Hirtz, Christophe; Lehmann, Sylvain
2015-01-01
Blood testing using the dried blood spot (DBS) is used since the 1960s in clinical analysis, mainly within the framework of the neonatal screening (Guthrie test). Since then numerous analytes such as nucleic acids, small molecules or lipids, were successfully measured on the DBS. While this pre-analytical method represents an interesting alternative to classic blood sampling, its use in routine is still limited. We review here the different clinical applications of the blood sampling on DBS and estimate its future place, supported by the new methods of analysis as the LC-MS mass spectrometry.
[Economic analysis versus the principle of guaranteed safety in blood transfusion].
Moatti, J P; Loubière, S; Rotily, M
2000-06-01
This article shows that policies aimed at reducing risks of infectious agents transmissible through blood unfortunately follow a law of 'diminishing returns': increasing marginal costs have to be devoted for limited reductions in the risks of contamination through blood donations. Therefore, the economic cost-effectiveness analysis is appropriate to identify screening strategies which may minimize costs to reach a certain level of safety. Moreover, economic analysis can contribute to public debates about the level of residual risk that society is willing to accept. Empirical results from French studies about screening for hepatitis C virus (HCV) in individuals who have received blood transfusions and in blood donations are presented to illustrate these points.
Tscheulin, Dieter K; Lindenmeier, Jörg
2005-08-01
Since the willingness to donate blood is not very high among large parts of the population, a better understanding of the determinants for the willingness to donate blood is of significant importance. This article is intended to contribute to higher uniformity of results in the context of research on blood donation behaviour. Exploratory factor analysis non-parametric tests are used to accomplish this. Potentially important socio-demographic and motivation-related variables particularly affecting the willingness to donate blood are examined. As an addition to the existing literature, the influence of the individual importance structural of characteristics of blood donation facilities, such as the standard of the facility's medical equipment or the training of the facility's staff, will be tested for its effects on the willingness to donate blood. The analysis will also include the influence of direct or indirect personal involvement on the part of the respondent. The results of the study indicate that typical blood donors are young women or men who are studying or possess a higher level of education. Furthermore, potential blood donors can easily be attracted by pecuniary incentives and word of mouth. Unlike non-donors, potential blood donors are not idle, have no fear of infections due to the donation and want reasonable opening hours of blood donation facilities.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fields, C.L.; Roy, T.M.; Dow, F.T.
1992-04-01
The Department of Labor has set guidelines for the use of resting arterial blood gas analysis in determination of total and permanent disability for coal workers' pneumoconiosis. To determine the prevalence with which bituminous coal miners fall below the arterial tensions of both oxygen and carbon dioxide published in the Federal Register, we studied 1012 miners who had both reproducible spirometry and arterial blood gas analysis as part of their disability evaluation. Eighty-seven percent of impaired miners could be identified by the spirometric criteria. Thirteen percent of impaired bituminous coal miners had acceptable pulmonary function but were eligible for blackmore » lung benefits by the blood gas guidelines. This population would have been missed if blood gas analysis were excluded from the evaluation process. On the other hand, approximately 25% of the blood gas analyses that were performed could be eliminated if a policy was adopted to do this test only on miners with spirometry that exceed the federal guidelines.« less
Changes in plasma protein levels as an early indication of a bloodstream infection
Joenväärä, Sakari; Kaartinen, Johanna; Järvinen, Asko; Renkonen, Risto
2017-01-01
Blood culture is the primary diagnostic test performed in a suspicion of bloodstream infection to detect the presence of microorganisms and direct the treatment. However, blood culture is slow and time consuming method to detect blood stream infections or separate septic and/or bacteremic patients from others with less serious febrile disease. Plasma proteomics, despite its challenges, remains an important source for early biomarkers for systemic diseases and might show changes before direct evidence from bacteria can be obtained. We have performed a plasma proteomic analysis, simultaneously at the time of blood culture sampling from ten blood culture positive and ten blood culture negative patients, and quantified 172 proteins with two or more unique peptides. Principal components analysis, Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) and ROC curve analysis were performed to select protein(s) features which can classify the two groups of samples. We propose a number of candidates which qualify as potential biomarkers to select the blood culture positive cases from negative ones. Pathway analysis by two methods revealed complement activation, phagocytosis pathway and alterations in lipid metabolism as enriched pathways which are relevant for the condition. Data are available via ProteomeXchange with identifier PXD005022. PMID:28235076
Preventing blood transfusion failures: FMEA, an effective assessment method.
Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza
2017-06-30
Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.
Tomaszewski, Maciej; Debiec, Radoslaw; Braund, Peter S; Nelson, Christopher P; Hardwick, Robert; Christofidou, Paraskevi; Denniff, Matthew; Codd, Veryan; Rafelt, Suzanne; van der Harst, Pim; Waterworth, Dawn; Song, Kijoung; Vollenweider, Peter; Waeber, Gerard; Zukowska-Szczechowska, Ewa; Burton, Paul R; Mooser, Vincent; Charchar, Fadi J; Thompson, John R; Tobin, Martin D; Samani, Nilesh J
2010-01-01
Genetic determinants of blood pressure are poorly defined. We undertook a large-scale gene-centric analysis to identify loci and pathways associated with ambulatory systolic and diastolic blood pressure. We measured 24-hour ambulatory BP in 2020 individuals from 520 white European nuclear families (the GRAPHIC Study) and genotyped their DNA using the Illumina HumanCVD BeadChip array which contains approximately 50000 single nucleotide polymorphisms in >2000 cardiovascular candidate loci. We found a strong association between rs13306560 polymorphism in the promoter region of MTHFR and CLCN6 and mean 24-hour diastolic blood pressure - each minor allele copy of rs13306560 was associated with 2.6 mmHg lower mean 24-hour diastolic blood pressure (P=1.2×10−8). rs13306560 was also associated with clinic diastolic blood pressure in a combined analysis of 8129 subjects from the GRAPHIC Study, the CoLaus Study and the Silesian Cardiovascular Study (P=5.4×10−6). Additional analysis of associations between variants in Gene Ontology-defined pathways and mean 24-hour blood pressure in the GRAPHIC Study showed that cell survival control signalling cascades could play a role in blood pressure regulation. There was also a significant over-representation of rare variants (minor allele frequency <0.05) amongst polymorphisms showing at least nominal association with mean 24-hour blood pressure indicating that a considerable proportion of its heritability may be explained by uncommon alleles. Through a large scale gene-centric analysis of ambulatory blood pressure, we identified an association of a novel variant at the MTHFR/CLNC6 locus with diastolic blood pressure and provided new insights into the genetic architecture of blood pressure. PMID:21060006
De Boer, Jan L M; Ritsema, Rob; Piso, Sjoerd; Van Staden, Hans; Van Den Beld, Wilbert
2004-07-01
Two screening methods were developed for rapid analysis of a great number of urine and blood samples within the framework of an exposure check of the population after a firework explosion. A total of 56 elements was measured including major elements. Sample preparation consisted of simple dilution. Extensive quality controls were applied including element addition and the use of certified reference materials. Relevant results at levels similar to those found in the literature were obtained for Co, Ni, Cu, Zn, Sr, Cd, Sn, Sb, Ba, Tl, and Pb in urine and for the same elements except Ni, Sn, Sb, and Ba in blood. However, quadrupole ICP-MS has limitations, mainly related to spectral interferences, for the analysis of urine and blood, and these cause higher detection limits. The general aspects discussed in the paper give it wider applicability than just for analysis of blood and urine-it can for example be used in environmental analysis.
Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D
2012-10-01
The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using the wavelet analysis of blood flow oscillations in rats. Twelve Sprague-Dawley rats were randomly assigned to three protocols, including pressure with local cooling (Δt = -10 °C), pressure with local heating (Δt = 10 °C) and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 h. Skin blood flow was measured using laser Doppler flowmetry. The 3 h loading period was divided into non-overlapping 30 min epochs for the analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased under the conditions of pressure with heating and of pressure without temperature changes, but maintained stable under the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers.
Jan, Yih-Kuen; Lee, Bernard; Liao, Fuyuan; Foreman, Robert D.
2012-01-01
The objectives of this study were to investigate the effects of local cooling on skin blood flow response to prolonged surface pressure and to identify associated physiological controls mediating these responses using wavelet analysis of blood flow oscillations in rats. Twelve Sprague Dawley rats were randomly assigned into three protocols, including pressure with local cooling (Δt= −10°C), pressure with local heating (Δt= 10°C), and pressure without temperature changes. Pressure of 700 mmHg was applied to the right trochanter area of rats for 3 hours. Skin blood flow was measured using laser Doppler flowmetry. The 3-hour loading period was divided into non-overlapping 30 min epochs for analysis of the changes of skin blood flow oscillations using wavelet spectral analysis. The wavelet amplitudes and powers of three frequencies (metabolic, neurogenic and myogenic) of skin blood flow oscillations were calculated. The results showed that after an initial loading period of 30 min, skin blood flow continually decreased in the conditions of pressure with heating and of pressure without temperature changes, but maintained stable in the condition of pressure with cooling. Wavelet analysis revealed that stable skin blood flow under pressure with cooling was attributed to changes in the metabolic and myogenic frequencies. This study demonstrates that local cooling may be useful for reducing ischemia of weight-bearing soft tissues that prevents pressure ulcers. PMID:23010955
Blood gas analysis as a determinant of occupationally related disability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morgan, W.K.; Zaldivar, G.L.
1990-05-01
Arterial blood gas analysis is one of the criteria used by the Department of Labor to award total and permanent disability for coal workers' pneumoconiosis (Black Lung). We have observed that Black Lung claimants often undergo several blood gas analyses with widely differing results that sometimes range from complete normality to life-threatening hypoxemia in the same subject. We concluded that blood gas analysis in occupationally related disability determination is unreliable, in that quality control and instrumentation are variable; that severe hypoxemia is rare in coal workers' pneumoconiosis; and that such hypoxemia is nonspecific and correlates poorly with breathlessness.
2009-06-05
were obtained: (1) blood analysis before, immediately after, and 24 hours after exposure, (2) 12-lead electrocardiogram (ECG) recordings before and...this report focuses on the blood chemistry analysis, ECG evaluation, psychomotor function assessment, and post-exposure interview findings. 15. SUBJECT... Blood Chemistry Characteristics ................ 13 Table 2: Summary of Electrocardiogram Analysis Before and After X-26 TASER® Exposure
... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... there is a problem with your body's electrolyte balance or acid-base (pH) balance and to monitor ...
Romay-Tallon, Raquel; Rivera-Baltanas, Tania; Allen, Josh; Olivares, Jose M; Kalynchuk, Lisa E; Caruncho, Hector J
2017-01-01
The pattern of serotonin transporter clustering on the plasma membrane of lymphocytes extracted from human whole blood samples has been identified as a putative biomarker of therapeutic efficacy in major depression. Here we evaluated the possibility of performing a similar analysis using blood smears obtained from rats, and from control human subjects and depression patients. We hypothesized that we could optimize a protocol to make the analysis of serotonin protein clustering in blood smears comparable to the analysis of serotonin protein clustering using isolated lymphocytes. Our data indicate that blood smears require a longer fixation time and longer times of incubation with primary and secondary antibodies. In addition, one needs to optimize the image analysis settings for the analysis of smears. When these steps are followed, the quantitative analysis of both the number and size of serotonin transporter clusters on the plasma membrane of lymphocytes is similar using both blood smears and isolated lymphocytes. The development of this novel protocol will greatly facilitate the collection of appropriate samples by eliminating the necessity and cost of specialized personnel for drawing blood samples, and by being a less invasive procedure. Therefore, this protocol will help us advance the validation of membrane protein clustering in lymphocytes as a biomarker of therapeutic efficacy in major depression, and bring it closer to its clinical application.
Raising the sauropod neck: it costs more to get less
Seymour, Roger S.
2009-01-01
The long necks of gigantic sauropod dinosaurs are commonly assumed to have been used for high browsing to obtain enough food. However, this analysis questions whether such a posture was reasonable from the standpoint of energetics. The energy cost of circulating the blood can be estimated accurately from two physiological axioms that relate metabolic rate, blood flow rate and arterial blood pressure: (i) metabolic rate is proportional to blood flow rate and (ii) cardiac work rate is proportional to the product of blood flow rate and blood pressure. The analysis shows that it would have required the animal to expend approximately half of its energy intake just to circulate the blood, primarily because a vertical neck would have required a high systemic arterial blood pressure. It is therefore energetically more feasible to have used a more or less horizontal neck to enable wide browsing while keeping blood pressure low. PMID:19364714
Raising the sauropod neck: it costs more to get less.
Seymour, Roger S
2009-06-23
The long necks of gigantic sauropod dinosaurs are commonly assumed to have been used for high browsing to obtain enough food. However, this analysis questions whether such a posture was reasonable from the standpoint of energetics. The energy cost of circulating the blood can be estimated accurately from two physiological axioms that relate metabolic rate, blood flow rate and arterial blood pressure: (i) metabolic rate is proportional to blood flow rate and (ii) cardiac work rate is proportional to the product of blood flow rate and blood pressure. The analysis shows that it would have required the animal to expend approximately half of its energy intake just to circulate the blood, primarily because a vertical neck would have required a high systemic arterial blood pressure. It is therefore energetically more feasible to have used a more or less horizontal neck to enable wide browsing while keeping blood pressure low.
... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... must be careful to maintain fluid and electrolyte balance. Kidney failure is a possible complication of Bartter ...
Does chocolate reduce blood pressure? A meta-analysis.
Ried, Karin; Sullivan, Thomas; Fakler, Peter; Frank, Oliver R; Stocks, Nigel P
2010-06-28
Dark chocolate and flavanol-rich cocoa products have attracted interest as an alternative treatment option for hypertension, a known risk factor for cardiovascular disease. Previous meta-analyses concluded that cocoa-rich foods may reduce blood pressure. Recently, several additional trials have been conducted with conflicting results. Our study summarises current evidence on the effect of flavanol-rich cocoa products on blood pressure in hypertensive and normotensive individuals. We searched Medline, Cochrane and international trial registries between 1955 and 2009 for randomised controlled trials investigating the effect of cocoa as food or drink compared with placebo on systolic and diastolic blood pressure (SBP/DBP) for a minimum duration of 2 weeks. We conducted random effects meta-analysis of all studies fitting the inclusion criteria, as well as subgroup analysis by baseline blood pressure (hypertensive/normotensive). Meta-regression analysis explored the association between type of treatment, dosage, duration or baseline blood pressure and blood pressure outcome. Statistical significance was set at P < 0.05. Fifteen trial arms of 13 assessed studies met the inclusion criteria. Pooled meta-analysis of all trials revealed a significant blood pressure-reducing effect of cocoa-chocolate compared with control (mean BP change +/- SE: SBP: -3.2 +/- 1.9 mmHg, P = 0.001; DBP: -2.0 +/- 1.3 mmHg, P = 0.003). However, subgroup meta-analysis was significant only for the hypertensive or prehypertensive subgroups (SBP: -5.0 +/- 3.0 mmHg; P = 0.0009; DBP: -2.7 +/- 2.2 mm Hg, P = 0.01), while BP was not significantly reduced in the normotensive subgroups (SBP: -1.6 +/- 2.3 mmHg, P = 0.17; DBP: -1.3 +/- 1.6 mmHg, P = 0.12). Nine trials used chocolate containing 50% to 70% cocoa compared with white chocolate or other cocoa-free controls, while six trials compared high- with low-flavanol cocoa products. Daily flavanol dosages ranged from 30 mg to 1000 mg in the active treatment groups, and interventions ran for 2 to 18 weeks. Meta-regression analysis found study design and type of control to be borderline significant but possibly indirect predictors for blood pressure outcome. Our meta-analysis suggests that dark chocolate is superior to placebo in reducing systolic hypertension or diastolic prehypertension. Flavanol-rich chocolate did not significantly reduce mean blood pressure below 140 mmHg systolic or 80 mmHg diastolic.
Analysis of benzodiazepines and their metabolites using DBS cards and LC-MS/MS.
Lee, Heesang; Park, Yujin; Jo, Jiyeong; In, Sangwhan; Park, Yonghoon; Kim, Eunmi; Pyo, Jaesung; Choe, Sanggil
2015-10-01
Dried Blood Spot (DBS) has been used a blood extraction method for inherited metabolic disorder screening since 1960s. With introduction of LC-MS/MS, not only DBS could be used to analysis drugs in small blood volume, but in various fields, such as toxicology, drug therapeutic monitoring, drug diagnostic screening, and illicit drugs. In toxicology field, many drugs (e.g. benzodiazepines, acetaminophen, small molecule drugs) have been tested with DBS. Compared with earlier blood extraction methods (SPE and LLE), DBS has lots of advantages; lower blood volume (less than 50μL), shorter analysis time caused by a more concise analysis procedure and lower cost. We optimized the DBS procedure and LC-MS/MS conditions for 18 benzodiazepines, seven benzodiazepine metabolites, and one z-drug (zolpidem) analysis in blood. 30μL of whole blood was spotted on FTA DMPK card C and dried for 2h in a desiccator. A 6-mm disk was punched and vortexed for 1min in a centrifuge tube with 300μL methanol/acetonitrile mixture (1:1, v/v). After evaporation, redissolved in 100μL mobile phase of LC-MS/MS and 5μL was injected. In the analysis for 26 target compounds in blood, all of the method validation parameters - LLOD, LLOQ, accuracy (intra- and inter-assay), and precision (intra- and inter-assay) - were satisfied with method validation criteria, within 15%. The results of matrix effect, recovery, and process efficiency were good. We developed a fast and reliable sample preparation method using DBS for 26 benzodiazepines, benzodiazepine metabolites, and z-drug (zolpidem). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Lin, Susie; McKenna, Samuel J; Yao, Chuan-Fong; Chen, Yu-Ray; Chen, Chit
2017-01-01
The objective of this study was to evaluate the efficacy of hypotensive anesthesia in reducing intraoperative blood loss, decreasing operation time, and improving the quality of the surgical field during orthognathic surgery. A systematic review and meta-analysis of randomized controlled trials addressing these issues were carried out. An electronic database search was performed. The risk of bias was evaluated with the Jadad Scale and Delphi List. The inverse variance statistical method and a random-effects model were used. Ten randomized controlled trials were included for analysis. Our meta-analysis indicated that hypotensive anesthesia reduced intraoperative blood loss by a mean of about 169 mL. Hypotensive anesthesia was not shown to reduce the operation time for orthognathic surgery, but it did improve the quality of the surgical field. Subgroup analysis indicated that for blood loss in double-jaw surgery, the weighted mean difference favored the hypotensive group, with a reduction in blood loss of 175 mL, but no statistically significant reduction in blood loss was found for anterior maxillary osteotomy. If local anesthesia with epinephrine was used in conjunction with hypotensive anesthesia, the reduction in intraoperative blood loss was increased to 254.93 mL. Hypotensive anesthesia was effective in reducing blood loss and improving the quality of the surgical field, but it did not reduce the operation time for orthognathic surgery. The use of local anesthesia in conjunction with hypotensive general anesthesia further reduced the amount of intraoperative blood loss for orthognathic surgery. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
[Study on rules of TCM syndrome in patients with dyslipidemia and its objectization].
Lei, Yan; Wang, Zhen-Hua; Liu, Jian-Gang
2007-12-01
To explore the rules of TCM syndrome in patients with dyslipidemia and its relation with C-reactive protein (CRP), homocysteine (Hcy), carotid ultrasonic picture, blood lipids and blood viscosity. From 152 recruited patients symptoms and physical signs (including figures of tongue and pulse) were selected and analyzed in grading and quantifying by factor analysis. At the same time, blood lipids, CRP, Hcy, carotid ultrasonic picture and blood viscosity were detected to conduct a canonical correlation analysis for exploring the relationship between different TCM syndromes and their corresponding physical and/or chemical indexes. Five types of TCM syndrome obtained by factor analysis were syndrome of Shen-yin deficiency (I), Pi-qi deficiency (II), turbid-phlegm impediment (III), blood stasis (IV), and phlegm-blood block (V). By canonical correlation analysis, they were characterized with: Type I, high levels of CRP and blood viscosity; Type II, high level of very low-density lipoprotein cholesterol (VLDL-C); Type III, high level of total cholesterol (TC) and low level of high-density lipoprotein cholesterol (HDL-C); and Type V, high level of Hcy. The five syndrome types frequently found in patients with dyslipidemia are syndrome of Shen-yin deficiency, Pi-qi deficiency, turbid-phlegm impediment, blood stasis, and phlegm-blood block. Different syndrome has its own correlation with some corresponding physical and/or chemical laboratory indexes, the issue provides new evidences for the objectification of TCM syndromes in patients with dyslipidemia.
Renal blood flow dynamics in inbred rat strains provides insight into autoregulation.
A Mitrou, Nicholas G; Cupples, William A
2014-01-01
Renal autoregulation maintains stable renal blood flow in the face of constantly fluctuating blood pressure. Autoregulation is also the only mechanism that protects the delicate glomerular capillaries when blood pressure increases. In order to understand autoregulation, the renal blood flow response to changing blood pressure is studied. The steadystate response of blood flow is informative, but limits investigation of the individual mechanisms of autoregulation. The dynamics of autoregulation can be probed with transfer function analysis. The frequency-domain analysis of autoregulation allows investigators to probe the relative activity of each mechanism of autoregulation. We discuss the methodology and interpretation of transfer function analysis. Autoregulation is routinely studied in the rat, of which there are many inbred strains. There are multiple strains of rat that are either selected or inbred as models of human pathology. We discuss relevant characteristics of Brown Norway, Spontaneously hypertensive, Dahl, and Fawn-Hooded hypertensive rats and explore differences among these strains in blood pressure, dynamic autoregulation, and susceptibility to hypertensive renal injury. Finally we show that the use of transfer function analysis in these rat strains has contributed to our understanding of the physiology and pathophysiology of autoregulation and hypertensive renal disease.Interestingly all these strains demonstrate effective tubuloglomerular feedback suggesting that this mechanism is not sufficient for effective autoregulation. In contrast, obligatory or conditional failure of the myogenic mechanism suggests that this component is both necessary and sufficient for autoregulation.
Ji, Peng; Wei, Yanming; Hua, Yongli; Zhang, Xiaosong; Yao, Wanling; Ma, Qi; Yuan, Ziwen; Wen, Yanqiao; Yang, Chaoxue
2018-01-30
Angelica sinensis (AS), root of Angelica sinensis (Oliv.) Diels, an important kind of Chinese traditional herbal medicine, has been used for women to enrich the blood for thousands of years. It is mainly distributed in Gansu province of China. According to Traditional Chinese medicine usage, unprocessed AS (UAS) and its 4 kinds of processed products (ASs) are all used to treat different diseases or syndromes. The difference among the enriching-blood effects of ASs is unclear. And their exact mechanisms of enriching the blood are not fully understood. In this study, our aim is to compare the enriching-blood effect and explain the related mechanism of ASs, to lay the foundation for the blood deficiency diagnosis and the rational use of ASs in the clinic. ASs were used to intervene the blood deficiency syndrome model mice induced by acetyl phenylhydrazine (APH) and cyclophosphamide (CTX). A novel approach using metabolomics coupled with hematological and biochemical parameters to explain the enriching-blood effect and mechanism of ASs was established. The blood routine examination, ATPase, glucose-6-phosphate dehydrogenase, methemoglobin, glutathion peroxidase, glutathione reductase, and erythropoietin were measured. Two biofluids (plasma and urine) obtained from mice were analyzed with GC-MS. Distinct changes in metabolite patterns of the two biofluids after mice were induced by APH and CTX, and mice were intervened with ASs were analyzed using partial least squares-discriminant analysis. Potential biomarkers were found using a novel method including variable importance in the projection (VIP) >1.0, volcano plot analysis, and significance analysis of microarray. The results of hematological, biochemical parameters and the integrated metabolomics all showed the blood deficiency syndrome model was built successfully, ASs exhibited different degree of enriching-blood effect, and AS pached with alcohol (AAS) exhibited the best enriching-blood effect. 16 metabolites in the plasma and 8 metabolites in the urine were considered as the potential biomarkers. These metabolites were involved in 7 metabolic pathways which were concerned with the different enriching-blood effect mechanisms of ASs. The correlation analysis results confirmed L-Valine (plasma), Linoleic acid (urine), L-Aspartic acid (urine) and Cholesterol (urine) were strong positive or negative associated with biochemical indicators. The enriching-blood effects of ASs are different. The pathological mechanisms of blood deficiency syndrome and the enriching-blood effect mechanism of ASs are involved in 7 metabolic pathways. L-Valine (plasma), Linoleic acid (urine), L-Aspartic acid (urine), Cholesterol (urine) are four important biomarkers being related to the enriching-blood effect of ASs. The combination of VIP, volcano plot analysis and significance analysis of microarray is suitable for screening biomarkers in metabolomics study. They can lay the foundation for clinical practice. Copyright © 2017 Elsevier B.V. All rights reserved.
Clostridium difficile and C. difficile Toxin Testing
... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... other infections, typically for an extended period, the balance of the normal flora in the digestive tract ...
Cost-effective and Rapid Blood Analysis on a Cell-phone
Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan
2013-01-01
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings. PMID:23392286
Cost-effective and rapid blood analysis on a cell-phone.
Zhu, Hongying; Sencan, Ikbal; Wong, Justin; Dimitrov, Stoyan; Tseng, Derek; Nagashima, Keita; Ozcan, Aydogan
2013-04-07
We demonstrate a compact and cost-effective imaging cytometry platform installed on a cell-phone for the measurement of the density of red and white blood cells as well as hemoglobin concentration in human blood samples. Fluorescent and bright-field images of blood samples are captured using separate optical attachments to the cell-phone and are rapidly processed through a custom-developed smart application running on the phone for counting of blood cells and determining hemoglobin density. We evaluated the performance of this cell-phone based blood analysis platform using anonymous human blood samples and achieved comparable results to a standard bench-top hematology analyser. Test results can either be stored on the cell-phone memory or be transmitted to a central server, providing remote diagnosis opportunities even in field settings.
Biaoxue, Rong; Shuanying, Yang
2018-01-01
Many studies have evaluated the accuracy of EGFR mutation status in blood against that in tumor tissues as the reference. We conducted this systematic review and meta-analysis to assess whether blood can be used as a substitute for tumor tissue in detecting EGFR mutations. Investigations that provided data on EGFR mutation status in blood were searched in the databases of Medline, Embase, Ovid Technologies and Web of Science. The detect efficiency of EGFR mutations in paired blood and tissues was compared using a random-effects model of meta-analysis. Pooled sensitivity and specificity and diagnostic accuracy were calculated by receiver operating characteristic curve. A total of 19 studies with 2,922 individuals were involved in this meta-analysis. The pooled results showed the positive detection rate of EGFR mutations in lung cancer tissues was remarkably higher than that of paired blood samples (odds ratio [OR] = 1.47, p<0.001). The pooled sensitivity and specificity of blood were 0.65 and 0.91, respectively, and the area under the receiver operating characteristic curve was 0.89. Although blood had a better specificity for detecting EGFR mutations, the absence of blood positivity should not necessarily be construed as confirmed negativity. Patients with negative results for blood should decidedly undergo further biopsies to ascertain EGFR mutations.
Gastroduodenal Ulcers and ABO Blood Group: the Japan Nurses' Health Study (JNHS).
Alkebsi, Lobna; Ideno, Yuki; Lee, Jung-Su; Suzuki, Shosuke; Nakajima-Shimada, Junko; Ohnishi, Hiroshi; Sato, Yasunori; Hayashi, Kunihiko
2018-01-05
Although several studies have shown that blood type O is associated with increased risk of peptic ulcer, few studies have investigated these associations in Japan. We sought to investigate the association between the ABO blood group and risk of gastroduodenal ulcers (GDU) using combined analysis of both retrospective and prospective data from a large cohort study of Japanese women, the Japan Nurses' Health Study (JNHS; n = 15,019). The impact of the ABO blood group on GDU risk was examined using Cox regression analysis to estimate hazard ratios (HRs) and 95% confidence intervals (CI), with adjustment for potential confounders. Compared with women with non-O blood types (A, B, and AB), women with blood type O had a significantly increased risk of GDU from birth (multivariable-adjusted HR 1.18; 95% CI, 1.04-1.34). Moreover, the highest cumulative incidence of GDU was observed in women born pre-1956 with blood type O. In a subgroup analysis stratified by birth year (pre-1956 or post-1955), the multivariable-adjusted HR of women with blood type O was 1.22 (95% CI, 1.00-1.49) and 1.15 (95% CI, 0.98-1.35) in the pre-1956 and post-1955 groups, respectively. In this large, combined, ambispective cohort study of Japanese women, older women with blood type O had a higher risk of developing GDU than those with other blood types.
Analysis of Blood Flow in a Partially Blocked Bifurcated Blood Vessel
NASA Astrophysics Data System (ADS)
Abdul-Razzak, Hayder; Elkassabgi, Yousri; Punati, Pavan K.; Nasser, Naseer
2009-09-01
Coronary artery disease is a major cause of death in the United States. It is the narrowing of the lumens of the coronary blood vessel by a gradual build-up of fatty material, atheroma, which leads to the heart muscle not receiving enough blood. This my ocardial ischemia can cause angina, a heart attack, heart failure as well as sudden cardiac death [9]. In this project a solid model of bifurcated blood vessel with an asymmetric stenosis is developed using GAMBIT and imported into FLUENT for analysis. In FLUENT, pressure and velocity distributions in the blood vessel are studied under different conditions, where the size and position of the blockage in the blood vessel are varied. The location and size of the blockage in the blood vessel are correlated with the pressures and velocities distributions. Results show that such correlation may be used to predict the size and location of the blockage.
Lu, Jun; Li, Li-Ming; He, Ping-Ping; Cao, Wei-Hua; Zhan, Si-Yan; Hu, Yong-Hua
2004-06-01
To introduce the application of mixed linear model in the analysis of secular trend of blood pressure under antihypertensive treatment. A community-based postmarketing surveillance of benazepril was conducted in 1831 essential hypertensive patients (age range from 35 to 88 years) in Shanghai. Data of blood pressure was analyzed every 3 months with mixed linear model to describe the secular trend of blood pressure and changes of age-specific and gender-specific. The changing trends of systolic blood pressure (SBP) and diastolic blood pressure (DBP) were found to fit the curvilinear models. A piecewise model was fit for pulse pressure (PP), i.e., curvilinear model in the first 9 months and linear model after 9 months of taking medication. Both blood pressure and its velocity gradually slowed down. There were significant variation for the curve parameters of intercept, slope, and acceleration. Blood pressure in patients with higher initial levels was persistently declining in the 3-year-treatment. However blood pressures of patients with relatively low initial levels remained low when dropped down to some degree. Elderly patients showed high SBP but low DBP, so as with higher PP. The velocity and sizes of blood pressure reductions increased with the initial level of blood pressure. Mixed linear model is flexible and robust when applied to the analysis of longitudinal data but with missing values and can also make the maximum use of available information.
Blood Pressure and Cognition Among Older Adults: A Meta-Analysis
Gifford, Katherine A.; Badaracco, Maria; Liu, Dandan; Tripodis, Yorghos; Gentile, Amanda; Lu, Zengqi; Palmisano, Joseph; Jefferson, Angela L.
2013-01-01
Hypertension has adverse effects on cognition, can alter cerebral vasculature integrity, and is associated with the pathogenesis of dementia. Using meta-analysis, we correlated blood pressure to multiple cognitive domains among older adults free of clinical stroke and dementia. We identified 230 studies indexed in PubMed and PsycINFO relating blood pressure and cognition. After applying exclusion criteria, we selected n = 12 articles with n = 4,076 participants (age range 43–91 years). Meta-analysis yielded an association between blood pressure and episodic memory (r = −.18, p < .001) and between blood pressure and global cognition (r = −.07, p < .001). When limiting analyses to studies adjusting for vascular covariates (n = 8, n = 2,141), blood pressure was modestly related to global cognition (r = −.11, p < .001), attention (r = .14, p = .002), and episodic memory (r = −.20, p < .001) with a trend for language (r = −.22, p = .07). Findings underscore the need to manage blood pressure as a key prevention method in minimizing abnormal cognitive aging prior to the onset of clinical dementia. PMID:23838685
Lei, Qiang; Lv, Yunhui; Li, Kai; Ma, Lei; Du, Guodong; Xiang, Yan; Li, Xuqing
2017-01-01
ABSTRACT Objective: To evaluate systematically the effects of continuous positive airway pressure (CPAP) on blood pressure in patients with resistant hypertension and obstructive sleep apnea (OSA). Methods: The Cochrane Library, PubMed, ScienceDirect, and the Web of Science were searched for studies investigating the effects of CPAP on blood pressure in patients with resistant hypertension and OSA. The selected studies underwent quality assessment and meta-analysis, as well as being tested for heterogeneity. Results: Six randomized controlled trials were included in the meta-analysis. The pooled estimates of the changes in mean systolic blood pressure and mean diastolic blood pressure (as assessed by 24-h ambulatory blood pressure monitoring) were −5.40 mmHg (95% CI: −9.17 to −1.64; p = 0.001; I2 = 74%) and −3.86 mmHg (95% CI: −6.41 to −1.30; p = 0.00001; I2 = 79%), respectively. Conclusions: CPAP therapy can significantly reduce blood pressure in patients with resistant hypertension and OSA. PMID:28767770
Hanna-Attisha, Mona; LaChance, Jenny; Sadler, Richard Casey; Champney Schnepp, Allison
2016-02-01
We analyzed differences in pediatric elevated blood lead level incidence before and after Flint, Michigan, introduced a more corrosive water source into an aging water system without adequate corrosion control. We reviewed blood lead levels for children younger than 5 years before (2013) and after (2015) water source change in Greater Flint, Michigan. We assessed the percentage of elevated blood lead levels in both time periods, and identified geographical locations through spatial analysis. Incidence of elevated blood lead levels increased from 2.4% to 4.9% (P < .05) after water source change, and neighborhoods with the highest water lead levels experienced a 6.6% increase. No significant change was seen outside the city. Geospatial analysis identified disadvantaged neighborhoods as having the greatest elevated blood lead level increases and informed response prioritization during the now-declared public health emergency. The percentage of children with elevated blood lead levels increased after water source change, particularly in socioeconomically disadvantaged neighborhoods. Water is a growing source of childhood lead exposure because of aging infrastructure.
LaChance, Jenny; Sadler, Richard Casey; Champney Schnepp, Allison
2016-01-01
Objectives. We analyzed differences in pediatric elevated blood lead level incidence before and after Flint, Michigan, introduced a more corrosive water source into an aging water system without adequate corrosion control. Methods. We reviewed blood lead levels for children younger than 5 years before (2013) and after (2015) water source change in Greater Flint, Michigan. We assessed the percentage of elevated blood lead levels in both time periods, and identified geographical locations through spatial analysis. Results. Incidence of elevated blood lead levels increased from 2.4% to 4.9% (P < .05) after water source change, and neighborhoods with the highest water lead levels experienced a 6.6% increase. No significant change was seen outside the city. Geospatial analysis identified disadvantaged neighborhoods as having the greatest elevated blood lead level increases and informed response prioritization during the now-declared public health emergency. Conclusions. The percentage of children with elevated blood lead levels increased after water source change, particularly in socioeconomically disadvantaged neighborhoods. Water is a growing source of childhood lead exposure because of aging infrastructure. PMID:26691115
Blood proteins analysis by Raman spectroscopy method
NASA Astrophysics Data System (ADS)
Artemyev, D. N.; Bratchenko, I. A.; Khristoforova, Yu. A.; Lykina, A. A.; Myakinin, O. O.; Kuzmina, T. P.; Davydkin, I. L.; Zakharov, V. P.
2016-04-01
This work is devoted to study the possibility of plasma proteins (albumin, globulins) concentration measurement using Raman spectroscopy setup. The blood plasma and whole blood were studied in this research. The obtained Raman spectra showed significant variation of intensities of certain spectral bands 940, 1005, 1330, 1450 and 1650 cm-1 for different protein fractions. Partial least squares regression analysis was used for determination of correlation coefficients. We have shown that the proposed method represents the structure and biochemical composition of major blood proteins.
Whole blood analysis rotor assembly having removable cellular sedimentation bowl
Burtis, C.A.; Johnson, W.F.
1975-08-26
A rotor assembly for performing photometric analyses using whole blood samples is described. Following static loading of a gross blood sample within a centrally located, removable, cell sedimentation bowl, the red blood cells in the gross sample are centrifugally separated from the plasma, the plasm displaced from the sedimentation bowl, and measured subvolumes of plasma distributed to respective sample analysis cuvettes positioned in an annular array about the rotor periphery. Means for adding reagents to the respective cuvettes are also described. (auth)
[Application of melting curve to analyze genotype of Duffy blood group antigen Fy-a/b].
Chen, Xue; Zhou, Chang-Hua; Hong, Ying; Gong, Tian-Xiang
2012-12-01
This study was aimed to establish the real-time multiple-PCR with melting curve analysis for Duffy blood group Fy-a/b genotyping. According to the sequence of mRNA coding for β-actin and Fy-a/b, the primers of β-actin and Fy-a/b were synthesized. The real-time multiple-PCR with melting curve analysis for Fy-a/b genotyping was established. The Fy-a/b genotyping of 198 blood donors in Chinese Chengdu area has been investigated by melting curve analysis and PCR-SSP. The results showed that the results of Fy-a/b genotype by melting curve analysis were consistent with PCR-SSP. In all of 198 donors in Chinese Chengdu, 178 were Fy(a) (+) (89.9%), 19 were Fy(a) (+) Fy(b) (+) (9.6%), and 1 was Fy(b) (+) (0.5%). The gene frequency of Fy(a) was 0.947, while that of Fy(b) was 0.053. It is concluded that the genotyping method of Duffy blood group with melting curve analysis is established, which can be used as a high-throughput screening tool for Duffy blood group genotyping; and the Fy(a) genotype is the major of Duffy blood group of donors in Chinese Chengdu area.
Zheng, Jun; Yu, Zhiyuan; Ma, Lu; Guo, Rui; Lin, Sen; You, Chao; Li, Hao
2018-03-16
Intracerebral hemorrhage (ICH) is a devastating subtype of stroke. Patients with ICH have poor functional outcomes. The association between blood glucose level and functional outcome in ICH remains unclear. This systematic review and meta-analysis aimed to investigate the association between blood glucose level and functional outcomes in patients with ICH. Literature was searched systemically in PubMed, EMBASE, Web of Science, and Cochrane Library. Published cohort studies evaluating the association between blood glucose and functional outcome in patients with ICH were included. This meta-analysis was performed using odds ratios (ORs) and 95% confidence intervals (CIs). A total of 16 studies were included in our meta-analysis. Our data show that hyperglycemia defined by cutoff values was significantly associated with unfavorable functional outcome (OR, 1.80; 95% CI, 1.36-2.39; P < 0.001). Our analysis also suggested a significant association between increased blood glucose levels and functional outcomes (OR, 1.05; 95% CI, 1.03-1.07; P < 0.001). High blood glucose level is significantly associated with poor functional outcome in ICH. Further studies with larger sample sizes, more time points, and longer follow-up times are necessary to confirm this association. Copyright © 2018 Elsevier Inc. All rights reserved.
Taylor, Kathryn S.; Heneghan, Carl J.; Stevens, Richard J.; Adams, Emily C.; Nunan, David; Ward, Alison
2015-01-01
In addition to mean blood pressure, blood pressure variability is hypothesized to have important prognostic value in evaluating cardiovascular risk. We aimed to assess the prognostic value of blood pressure variability within 24 hours. Using MEDLINE, EMBASE and Cochrane Library to April 2013, we conducted a systematic review of prospective studies of adults, with at least one year follow-up and any day, night or 24-hour blood pressure variability measure as a predictor of one or more of the following outcomes: all-cause mortality, cardiovascular mortality, all cardiovascular events, stroke and coronary heart disease. We examined how blood pressure variability is defined and how its prognostic use is reported. We analysed relative risks adjusted for covariates including the appropriate mean blood pressure and considered the potential for meta-analysis. Our analysis of methods included 24 studies and analysis of predictions included 16 studies. There were 36 different measures of blood pressure variability and 13 definitions of night- and day-time periods. Median follow-up was 5.5 years (interquartile range 4.2–7.0). Comparing measures of dispersion, coefficient of variation was less well researched than standard deviation. Night dipping based on percentage change was the most researched measure and the only measure for which data could be meaningfully pooled. Night dipping or lower night-time blood pressure was associated with lower risk of cardiovascular events. The interpretation and use in clinical practice of 24-hour blood pressure variability, as an important prognostic indicator of cardiovascular events, is hampered by insufficient evidence and divergent methodologies. We recommend greater standardisation of methods. PMID:25984791
Blood pressure and neuropsychological test performance in healthy postmenopausal women.
Alsumali, Adnan; Mekary, Rania A; Seeger, John; Regestein, Quentin
2016-06-01
To study the association between blood pressure and neuropsychological test performance in healthy postmenopausal women. Data from 88 healthy postmenopausal women aged 46-73 years, who were not experiencing hot flashes, and who had participated in a prior drug trial, were analyzed to find whether baseline blood pressure was associated with impaired performance on neuropsychological testing done at 3 follow-up visits separated by 4 weeks. Factor analysis was used to reduce the dimensions of neuropsychological test performance. Mixed linear modeling was used to evaluate the association between baseline blood pressure and repeatedly measured neuropsychological test performance at follow-up in a complete case analysis (n=53). In a sensitivity analysis (n=88), multiple-imputation using the Markov Chain Monte Carlo method was used to account for missing data (blood pressure results) for some visits. The variables recording neuropsychological test performance were reduced to two main factors (Factor 1=selective attention; Factor 2=complex processing). In the complete case analysis, the association between a 20-mmHg increase in diastolic blood pressure and Factor 1 remained statistically significant after adjusting for potential confounders, before adjusting for systolic blood pressure (slope=0.60; 95%CI=0.04,1.16), and after adjusting for systolic blood pressure (slope=0.76; 95%CI=0.06, 1.47). The positive slopes indicated an increase in the time spent performing a given task (i.e., a decrease in neuropsychological test performance). No other significant associations were found between systolic blood pressure and either factor. The results did not materially change after applying the multiple-imputation method. An increase in diastolic blood pressure was associated with a decrease in neuropsychological test performance among older healthy postmenopausal women experiencing hot flashes. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Leuthold, Luc Alexis; Heudi, Olivier; Déglon, Julien; Raccuglia, Marc; Augsburger, Marc; Picard, Franck; Kretz, Olivier; Thomas, Aurélien
2015-02-17
Hematocrit (Hct) is one of the most critical issues associated with the bioanalytical methods used for dried blood spot (DBS) sample analysis. Because Hct determines the viscosity of blood, it may affect the spreading of blood onto the filter paper. Hence, accurate quantitative data can only be obtained if the size of the paper filter extracted contains a fixed blood volume. We describe for the first time a microfluidic-based sampling procedure to enable accurate blood volume collection on commercially available DBS cards. The system allows the collection of a controlled volume of blood (e.g., 5 or 10 μL) within several seconds. Reproducibility of the sampling volume was examined in vivo on capillary blood by quantifying caffeine and paraxanthine on 5 different extracted DBS spots at two different time points and in vitro with a test compound, Mavoglurant, on 10 different spots at two Hct levels. Entire spots were extracted. In addition, the accuracy and precision (n = 3) data for the Mavoglurant quantitation in blood with Hct levels between 26% and 62% were evaluated. The interspot precision data were below 9.0%, which was equivalent to that of a manually spotted volume with a pipet. No Hct effect was observed in the quantitative results obtained for Hct levels from 26% to 62%. These data indicate that our microfluidic-based sampling procedure is accurate and precise and that the analysis of Mavoglurant is not affected by the Hct values. This provides a simple procedure for DBS sampling with a fixed volume of capillary blood, which could eliminate the recurrent Hct issue linked to DBS sample analysis.
Niknafs, Pedram; Norouzi, Elahe; Bahman Bijari, Bahareh; Baneshi, Mohammad Reza
2015-01-01
Neonates with respiratory distress syndrome (RDS), who are treated according to INSURE protocol; require arterial blood gas (ABG) analysis to decide on appropriate management. We conducted this study to investigate the validity of pulse oximetry instead of frequent ABG analysis in the evaluation of these patients. From a total of 193 blood samples obtained from 30 neonates <1500 grams with RDS, 7.2% were found to have one or more of the followings: acidosis, hypercapnia, or hypoxemia. We found that pulse oximetry in the detection of hyperoxemia had a good validity to appropriately manage patients without blood gas analysis. However, the validity of pulse oximetry was not good enough to detect acidosis, hypercapnia, and hypoxemia. PMID:25999627
Ndao, M; Kelly, N; Normandin, D; Maclean, J D; Whiteman, A; Kokoskin, E; Arevalo, I; Ward, B J
2000-12-01
Wild-caught New World monkeys (NWM) from Central or South America are often infected with Trypanosoma species, including T. cruzi. In humans, T. cruzi causes Chagas' disease. Even in closed monkey colonies, T. cruzi can be propagated by blood-to-blood exposure, sexual activity, and transplacental transmission. Animal handlers and laboratory staff who deal with blood and tissues from infected NWM are at riskfor acquiring Chagas' disease via accidental exposure. We screened 162 blood samples from wild-caught Saimiri sp. monkeys for Trypanosoma species infections by use of blood smear examination, ELISA, and polymerase chain reaction (PCR) analysis. Blood samples from 19 employees with recent history of monkey-associated injuries also were tested. Six percent (10/162) of the monkey samples were T. cruzi positive on the basis of blood smear examination results, 10.4% (17/162) were positive by ELISA results, and 26.5% (43/162) were positive by PCR results. Other organisms identified by PCR analysis included T. rangeli in two animals, Plasmodium spp. in two animals (P. malariae confirmed by PCR results) and microfilariae in one animal (morphologically, Mansonella perstans). Evidence of trypanosome infection was not found in the 19 employee samples on the basis of results of any of the three aforementioned tests. Close attention must be paid to worker safety where wild-caught NWM are used. The PCR analysis has a clear advantage over conventional techniques (ELISA, blood smear) for screening NWM for trypanosome infections during quarantine and after employee injury.
Swami, Kailash Kumar; Srivastava, Meera
2012-12-01
The present study was undertaken to compare the entomological situation by analyzing the blood meal of mosquitoes of canal irrigated and non-irrigated areas of Bikaner in order to explore scientific information on the vector biology and malaria burden profile and to plan proper strategies for malaria control and eradication. Adult mosquitoes were collected and the abdomen of the blood fed females were crushed on a filter paper for blood meal analysis and subjected to precipitin test. The blood meal analysis showed that Anopheles subpictus had a preference towards cattle blood, An. culicifacies and An. stephensi preferred human blood, while, An. annularis was noted to feed only on bovine blood. Although An. annularis, has been recently reported from the area, was found to feed exclusively on bovine blood, earlier reports suggest that this species is a vector of malaria and therefore preventive measures should be taken well in advance before this species gets established in the area.
NASA Astrophysics Data System (ADS)
Paudel, Hari P.; Jung, Yookyung; Raphael, Anthony; Alt, Clemens; Wu, Juwell; Runnels, Judith; Lin, Charles P.
2018-02-01
The present standard of blood cell analysis is an invasive procedure requiring the extraction of patient's blood, followed by ex-vivo analysis using a flow cytometer or a hemocytometer. We are developing a noninvasive optical technique that alleviates the need for blood extraction. For in-vivo blood analysis we need a high speed, high resolution and high contrast label-free imaging technique. In this proceeding report, we reported a label-free method based on differential epi-detection of forward scattered light, a method inspired by Jerome Mertz's oblique back-illumination microscopy (OBM) (Ford et al, Nat. Meth. 9(12) 2012). The differential epi-detection of forward light gives phase contrast image at diffraction-limited resolution. Unlike reflection confocal microscopy (RCM), which detects only sharp refractive index variation and suffers from speckle noise, this technique is suitable for detection of subtle variation of refractive index in biological tissue and it provides the shape and the size of cells. A custom built high speed electronic detection circuit board produces a real-time differential signal which yields image contrast based on phase gradient in the sample. We recorded blood flow in-vivo at 17.2k lines per second in line scan mode, or 30 frames per second (full frame), or 120 frame per second (quarter frame) in frame scan mode. The image contrast and speed of line scan data recording show the potential of the system for noninvasive blood cell analysis.
Gupta, Vikas; Bustamante, Mariana; Fredriksson, Alexandru; Carlhäll, Carl-Johan; Ebbers, Tino
2018-01-01
Assessment of blood flow in the left ventricle using four-dimensional flow MRI requires accurate left ventricle segmentation that is often hampered by the low contrast between blood and the myocardium. The purpose of this work is to improve left-ventricular segmentation in four-dimensional flow MRI for reliable blood flow analysis. The left ventricle segmentations are first obtained using morphological cine-MRI with better in-plane resolution and contrast, and then aligned to four-dimensional flow MRI data. This alignment is, however, not trivial due to inter-slice misalignment errors caused by patient motion and respiratory drift during breath-hold based cine-MRI acquisition. A robust image registration based framework is proposed to mitigate such errors automatically. Data from 20 subjects, including healthy volunteers and patients, was used to evaluate its geometric accuracy and impact on blood flow analysis. High spatial correspondence was observed between manually and automatically aligned segmentations, and the improvements in alignment compared to uncorrected segmentations were significant (P < 0.01). Blood flow analysis from manual and automatically corrected segmentations did not differ significantly (P > 0.05). Our results demonstrate the efficacy of the proposed approach in improving left-ventricular segmentation in four-dimensional flow MRI, and its potential for reliable blood flow analysis. Magn Reson Med 79:554-560, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
Prevalence and correlates of hospital-based autologous blood programs: a statewide survey.
Hull, A L; Neuhauser, D V; Goodnough, L T
1992-05-01
To identify potential barriers to use of autologous blood procurement to minimize homologous blood transfusion needs during elective surgery, the authors conducted a telephone survey of 120 blood bank directors, representing 138 Ohio hospitals. The prevalence of autologous blood procurement facilities, estimated volume of autologous blood, and attitudes and perceptions of the directors toward autologous blood predeposit programs were assessed. Analysis of the data indicated that 30% of Ohio hospitals have autologous blood procurement facilities; larger hospitals were more likely to have this facility. Overall, 5.5% of transfusions involve predeposited autologous blood. No significant differences were found according to hospital bed size or whether the hospital had a procurement facility. Blood bank directors perceived surgeons to be knowledgeable about autologous predeposit; patient demand and surgical practice were felt to be more effective in promoting the use of autologous blood at the hospital than were blood bank efforts. Directors who had autologous predeposit procurement facilities perceived that the facility provided a marketing advantage. Respondents from larger hospitals were more likely to perceive that these programs could be financially self-sufficient. The authors conclude that an economic cost-benefit analysis of hospital-based autologous blood procurement programs is important. Positive findings may influence transfusion services to adopt autologous blood procurement programs, whereas negative findings may convince hospitals that community blood donor facilities can provide better autologous blood procurement.
Multifactorial analysis of human blood cell responses to clinical total body irradiation
NASA Technical Reports Server (NTRS)
Yuhas, J. M.; Stokes, T. R.; Lushbaugh, C. C.
1972-01-01
Multiple regression analysis techniques are used to study the effects of therapeutic radiation exposure, number of fractions, and time on such quantal responses as tumor control and skin injury. The potential of these methods for the analysis of human blood cell responses is demonstrated and estimates are given of the effects of total amount of exposure and time of protraction in determining the minimum white blood cell concentration observed after exposure of patients from four disease groups.
A membrane-separator interface for mass-spectrometric analysis of blood plasma
NASA Astrophysics Data System (ADS)
Elizarov, A. Yu.; Gerasimov, D. G.
2014-09-01
We demonstrate the possibility of rapid mass-spectrometric determination of the content of anesthetic agents in blood plasma with the aid of a membrane-separator interface. The interface employs a hydrophobic selective membrane that is capable of separating various anesthetic drugs (including inhalation anesthetic sevofluran, noninhalation anesthetic thiopental, hypnotic propofol, and opioid analgesic fentanyl) from the blood plasma and introducing samples into a mass spectrometer. Analysis of the blood plasma was not accompanied by the memory effect and did not lead to membrane degradation. Results of clinical investigation of the concentration of anesthetics in the blood plasma of patients are presented.
Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis
Razi Naqvi, K.
2014-01-01
Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens’ theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells. PMID:24761307
Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis.
Razi Naqvi, K
2014-04-01
Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens' theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells.
Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application.
Sharareh, Behnam; Woolwine, Spencer; Satish, Siddarth; Abraham, Peter; Schwarzkopf, Ran
2015-01-01
Real-time monitoring of blood loss is critical in fluid management. Visual estimation remains the standard of care in estimating blood loss, yet is demonstrably inaccurate. Photometric analysis, which is the referenced "gold-standard" for measuring blood loss, is both time-consuming and costly. The purpose of this study was to evaluate the efficacy of a novel tablet-monitoring device for measurement of Hb loss during orthopaedic procedures. This is a prospective study of 50 patients in a consecutive series of joint arthroplasty cases. The novel System with Feature Extraction Technology was used to measure the amount of Hb contained within surgical sponges intra-operatively. The system's measures were then compared with those obtained via gravimetric method and photometric analysis. Accuracy was evaluated using linear regression and Bland-Altman analysis. Our results showed a significant positive correlation between Triton tablet system and photometric analysis with respect to intra-operative hemoglobin and blood loss at 0.92 and 0.91, respectively. This novel system can accurately determine Hb loss contained within surgical sponges. We believe that this user-friendly software can be used for measurement of total intraoperative blood loss and thus aid in a more accurate fluid management protocols during orthopaedic surgical procedures.
Influence of geomagnetic activity and atmospheric pressure in hypertensive adults.
Azcárate, T; Mendoza, B
2017-09-01
We performed a study of the systolic and diastolic arterial blood pressure behavior under natural variables such as the atmospheric pressure and the horizontal geomagnetic field component. We worked with a group of eight adult hypertensive volunteers, four men and four women, with ages between 18 and 27 years in Mexico City during a geomagnetic storm in 2014. The data was divided by gender, age, and day/night cycle. We studied the time series using three methods: correlations, bivariate analysis, and superposed epoch (within a window of 2 days around the day of occurrence of a geomagnetic storm) analysis, between the systolic and diastolic blood pressure and the natural variables. The correlation analysis indicated a correlation between the systolic and diastolic blood pressure and the atmospheric pressure and the horizontal geomagnetic field component, being the largest during the night. Furthermore, the correlation and bivariate analyses showed that the largest correlations are between the systolic and diastolic blood pressure and the horizontal geomagnetic field component. Finally, the superposed epoch analysis showed that the largest number of significant changes in the blood pressure under the influence of geomagnetic field occurred in the systolic blood pressure for men.
Influence of geomagnetic activity and atmospheric pressure in hypertensive adults
NASA Astrophysics Data System (ADS)
Azcárate, T.; Mendoza, B.
2017-09-01
We performed a study of the systolic and diastolic arterial blood pressure behavior under natural variables such as the atmospheric pressure and the horizontal geomagnetic field component. We worked with a group of eight adult hypertensive volunteers, four men and four women, with ages between 18 and 27 years in Mexico City during a geomagnetic storm in 2014. The data was divided by gender, age, and day/night cycle. We studied the time series using three methods: correlations, bivariate analysis, and superposed epoch (within a window of 2 days around the day of occurrence of a geomagnetic storm) analysis, between the systolic and diastolic blood pressure and the natural variables. The correlation analysis indicated a correlation between the systolic and diastolic blood pressure and the atmospheric pressure and the horizontal geomagnetic field component, being the largest during the night. Furthermore, the correlation and bivariate analyses showed that the largest correlations are between the systolic and diastolic blood pressure and the horizontal geomagnetic field component. Finally, the superposed epoch analysis showed that the largest number of significant changes in the blood pressure under the influence of geomagnetic field occurred in the systolic blood pressure for men.
Bogner, Viktoria; Baker, Henry V.; Kanz, Karl-Georg; Moldawer, L. L.; Mutschler, Wolf; Biberthaler, Peter
2014-01-01
Introduction As outcome to severe trauma is frequently affected by massive blood loss and consecutive hemorrhagic shock, replacement of red blood cell (RBC) units remains indispensable. Administration of RBC units is an independent risk factor for adverse outcome in patients with trauma. The impact of massive blood transfusion or uncrossmatched blood transfusion on the patients’ immune response in the early posttraumatic period remains unclear. Material Thirteen patients presenting with blunt multiple injuries (Injury Severity Score >16) were studied. Monocytes were obtained on admission and at 6, 12, 24, 48, and 72 hours after trauma. Biotinylated complementary RNA targets were hybridized to Affymetrix HG U 133A microarrays. The data were analyzed by a supervised analysis based on whether the patients received massive blood transfusions, and then subsequently, by hierarchical clustering, and by Ingenuity pathway analysis. Results Supervised analysis identified 224 probe sets to be differentially expressed (p < 0.001) in patients who received massive blood transfusion, when compared with those who did not. In addition, 331 probe sets were found differentially expressed (p < 0.001) in patients who received uncrossmatched RBC units in comparison with those who exclusively gained crossmatched ones. Functional pathway analysis of the respectively identified gene expression profiles suggests a contributory role by the AKT/PI3Kinase pathway, the mitogen-activated protein-kinase pathway, the Ubiquitin pathway, and the diverse inflammatory networks. Conclusion We exhibited for the first time a serial, sequential screening analysis of monocyte messenger RNA expression patterns in patients with multiple trauma indicating a strongly significant association between the patients’ genomic response in blood monocytes and massive or uncross-matched RBC substitution. PMID:19820587
Shu, Liqin; Huang, Kun
2018-07-01
Evidence suggests that supplementation of vitamin D cannot decrease blood pressure in normal populations. However, in randomized controlled trials (RCTs) with vitamin D deficient participants (defined as baseline serum 25[OH]D levels <30 ng/mL or 50 nmol/L), this effect is inconsistent and under debate. Thus, we performed this systematic review and meta-analysis to evaluate whether vitamin D supplementation could affect blood pressure parameters in vitamin D-deficient subjects. The PubMed, Web of Science, ScienceDirect, and Cochrane library databases were searched. Extracted data were pooled as weighted mean differences with 95% confidence intervals to evaluate the effects. Subgroup analysis was further conducted according to the characteristics of included studies. Seven RCTs that contained 560 participants were included in our meta-analysis. The pooled weighted mean difference of peripheral diastolic blood pressure was -1.65 mm Hg (95% confidence interval: -3.05 to -0.25, I 2 = 30.3%). No significant effect of vitamin D supplementation was found on other parameters. Subgroup analysis showed a significant decrease in peripheral systolic blood pressure and diastolic blood pressure in Asia, 8 weeks of intervention, and more than 5000 IU of daily vitamin D supplementation subgroups. For vitamin D-deficient patients, there is a small but significant fall in peripheral blood pressure but no significant fall in other blood pressure parameters with vitamin D supplementation. Further RCTs with large numbers of participants is still warranted to confirm these effects. Copyright © 2018 American Heart Association. Published by Elsevier Inc. All rights reserved.
Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis.
Poder, Thomas G; Nonkani, Wendyam G; Tsakeu Leponkouo, Élyonore
2015-07-01
The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43°C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43°C and even up to 45-46°C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. Copyright © 2015 Elsevier Inc. All rights reserved.
Shin, Young-Soo; Yoon, Jung-Ro; Lee, Hoon-Nyun; Park, Se-Hwan; Lee, Dae-Hee
2017-11-01
This meta-analysis was designed to compare the effectiveness and safety of intravenous (IV) versus topical administration of tranexamic acid (TXA) in patients undergoing primary total knee arthroplasty (TKA) by evaluating the need for allogenic blood transfusion, incidence of postoperative complications, volume of postoperative blood loss, and change in haemoglobin levels. Studies were included in this meta-analysis to check whether they assessed the allogenic blood transfusion rate, postoperative complications including pulmonary thromboembolism (PTE) or deep vein thrombosis (DVT), volume of postoperative blood loss via drainage, estimated blood loss, total blood loss, and change in haemoglobin levels before and after surgery in primary TKA with TXA administered through both the IV and topical routes. Ten studies were included in this meta-analysis. The proportion of patients requiring allogenic blood transfusion (OR 1.34, 95 % CI 0.63-2.81; n.s.) and the proportion of patients who developed postoperative complications including PTE or DVT (OR 0.85, 95 % CI 0.41 to 1.77; n.s.) did not significantly differ between the two groups. There was 52.3 mL less blood loss via drainage (95 % CI -50.74 to 185.66 mL; n.s.), 52.1 mL greater estimated blood loss (95 % CI -155.27 to 51.03 mL; n.s.), and 51.4 mL greater total blood loss (95 % CI -208.16 to 105.31 mL; n.s.) in the topical TXA group as compared to the IV TXA group. The two groups were also similar in terms of the change in haemoglobin levels (0.02 g/dL, 95 % CI -0.36 to 0.39 g/dL; n.s.). In primary TKA, there are no significant differences in the transfusion requirement, postoperative complications, blood loss, and change in haemoglobin levels between the IV and topical administration of TXA. In addition, results from subgroup analysis evaluating the effect of the times of TXA administration through the IV route suggested that double IV dose of TXA is more effective than single dose in terms of the transfusion requirements and blood loss via drainage. The current meta-analysis indicates that IV administration of 10 mg/kg of TXA 20 min before inflation of the tourniquet followed by 10 mg/kg of TXA 15 min before deflation of the tourniquet is effective and safe. The topical administration of 2 g of TXA mixed with 100 mL of normal saline after wound closure could be an alternative option in patients at greater risk of thromboembolic complications. Meta-analysis, Level III.
Jochim, Ryan C; Teixeira, Clarissa R; Laughinghouse, Andre; Mu, Jianbing; Oliveira, Fabiano; Gomes, Regis B; Elnaiem, Dia-Eldin; Valenzuela, Jesus G
2008-01-14
In the life cycle of Leishmania within the alimentary canal of sand flies the parasites have to survive the hostile environment of blood meal digestion, escape the blood bolus and attach to the midgut epithelium before differentiating into the infective metacyclic stages. The molecular interactions between the Leishmania parasites and the gut of the sand fly are poorly understood. In the present work we sequenced five cDNA libraries constructed from midgut tissue from the sand fly Lutzomyia longipalpis and analyzed the transcripts present following sugar feeding, blood feeding and after the blood meal has been processed and excreted, both in the presence and absence of Leishmania infantum chagasi. Comparative analysis of the transcripts from sugar-fed and blood-fed cDNA libraries resulted in the identification of transcripts differentially expressed during blood feeding. This included upregulated transcripts such as four distinct microvillar-like proteins (LuloMVP1, 2, 4 and 5), two peritrophin like proteins, a trypsin like protein (Lltryp1), two chymotrypsin like proteins (LuloChym1A and 2) and an unknown protein. Downregulated transcripts by blood feeding were a microvillar-like protein (LuloMVP3), a trypsin like protein (Lltryp2) and an astacin-like metalloprotease (LuloAstacin). Furthermore, a comparative analysis between blood-fed and Leishmania infected midgut cDNA libraries resulted in the identification of the transcripts that were differentially expressed due to the presence of Leishmania in the gut of the sand fly. This included down regulated transcripts such as four microvillar-like proteins (LuloMVP1,2, 4 and 5), a Chymotrypsin (LuloChym1A) and a carboxypeptidase (LuloCpepA1), among others. Upregulated midgut transcripts in the presence of Leishmania were a peritrophin like protein (LuloPer1), a trypsin-like protein (Lltryp2) and an unknown protein. This transcriptome analysis represents the largest set of sequence data reported from a specific sand fly tissue and provides further information of the transcripts present in the sand fly Lutzomyia longipalpis. This analysis provides the detailed information of molecules present in the midgut of this sand fly and the transcripts potentially modulated by blood feeding and by the presence of the Leishmania parasite. More importantly, this analysis suggests that Leishmania infantum chagasi alters the expression profile of certain midgut transcripts in the sand fly during blood meal digestion and that this modulation may be relevant for the survival and establishment of the parasite in the gut of the fly. Moreover, this analysis suggests that these changes may be occurring during the digestion of the blood meal and not afterwards.
Bernstein, P S; Minior, V K; Divon, M Y
1997-11-01
The presence of elevated nucleated red blood cell counts in neonatal blood has been associated with fetal hypoxia. We sought to determine whether small-for-gestational-age fetuses with abnormal umbilical artery Doppler velocity waveforms have elevated nucleated red blood cell counts. Hospital charts of neonates with the discharge diagnosis of small for gestational age (birth weight < 10th percentile) who were delivered between October 1988 and June 1995 were reviewed for antepartum testing, delivery conditions, and neonatal outcome. We studied fetuses who had an umbilical artery systolic/diastolic ratio within 3 days of delivery and a complete blood cell count on the first day of life. Multiple gestations, anomalous fetuses, and infants of diabetic mothers were excluded. Statistical analysis included the Student t test, chi 2 analysis, analysis of variance, and simple and stepwise regression. Fifty-two infants met the inclusion criteria. Those with absent or reversed end-diastolic velocity (n = 19) had significantly greater nucleated red blood cell counts than did those with end-diastolic velocity present (n = 33) (nucleated red blood cells/100 nucleated cells +/- SD: 135.5 +/- 138 vs 17.4 +/- 23.7, p < 0.0001). These infants exhibited significantly longer time intervals for clearance of nucleated red blood cells from their circulation (p < 0.0001). They also had lower birth weights (p < 0.05), lower initial platelet count (p = 0.0006), lower arterial cord blood pH (p < 0.05), higher cord blood base deficit (p < 0.05), and an increased likelihood of cesarean section for "fetal distress" (p < 0.05). Multivariate analysis demonstrated that absent or reversed end-diastolic velocity (p < 0.0001) and low birth weight (p < 0.0001) contributed to the elevation of the nucleated red blood cell count, whereas gestational age at delivery was not a significant contributor. We observed significantly greater nucleated red blood cell counts and lower platelet counts in small-for-gestational-age fetuses with abnormal umbilical artery Doppler studies. This may suggest that antenatal thrombotic events lead to an increased placental impedance. Fetal response to this chronic condition may result in an increased nucleated red blood cell count.
Selling blood and gametes during tough economic times: insights from Google search.
Wu, Jonathan A; Ngo, Tin C; Rothman, Cappy; Breyer, Benjamin N; Eisenberg, Michael L
2015-10-01
To use Google Insights search volume and publicly available economic indicators to test the hypothesis that sperm, egg, and blood donations increase during economic downturns and to demonstrate the feasibility of using Google search volume data to predict national trends in actual sperm, egg, and blood donations rates. Cross-correlation statistical analysis comparing Google search data for terms relating to blood, egg, and sperm donations with various economic indicators including the S&P 500 closing values, gross domestic product (GDP), the U.S. Index of Leading Indicators (U.S. Leading Index), gross savings rate, mortgage interest rates, unemployment rate, and consumer price index (CPI) from 2004-2011. A secondary analysis determined the Pearson correlation coefficient between Google search data with actual sperm, egg, and blood donation volume in the U.S. as measured by California Cryobank, the National Assisted Reproductive Technology Surveillance System, and the National Blood Collection and Utilization Survey, respectively. Significance of cross-correlation and Pearson correlation analysis as indicated by p value. There were several highly significant cross-correlation relationships between search volume and various economic indicators. Correlation between Google search volume for the term 'sperm donation,' 'egg donation,' and 'blood donation' with actual number of sperm, egg and blood donations in the United States demonstrated Pearson correlation coefficients of 0.2 (p > 0.10), -0.1 (p > 0.10), and 0.07 (p > 0.10), respectively. Temporal analysis showed an improved correlation coefficient of 0.9 (p < 0.05) for blood donation when shifted 12 months later relative to Google search volume. Google search volume data for search terms relating to sperm, egg, and blood donation increase during economic downturns. This finding suggests gamete and bodily fluid donations are influenced by market forces like other commodities. Google search may be useful for predicting blood donation trends but is more limited in predicting actual semen and oocyte donation patterns.
Failure mode and effect analysis in blood transfusion: a proactive tool to reduce risks.
Lu, Yao; Teng, Fang; Zhou, Jie; Wen, Aiqing; Bi, Yutian
2013-12-01
The aim of blood transfusion risk management is to improve the quality of blood products and to assure patient safety. We utilize failure mode and effect analysis (FMEA), a tool employed for evaluating risks and identifying preventive measures to reduce the risks in blood transfusion. The failure modes and effects occurring throughout the whole process of blood transfusion were studied. Each failure mode was evaluated using three scores: severity of effect (S), likelihood of occurrence (O), and probability of detection (D). Risk priority numbers (RPNs) were calculated by multiplying the S, O, and D scores. The plan-do-check-act cycle was also used for continuous improvement. Analysis has showed that failure modes with the highest RPNs, and therefore the greatest risk, were insufficient preoperative assessment of the blood product requirement (RPN, 245), preparation time before infusion of more than 30 minutes (RPN, 240), blood transfusion reaction occurring during the transfusion process (RPN, 224), blood plasma abuse (RPN, 180), and insufficient and/or incorrect clinical information on request form (RPN, 126). After implementation of preventative measures and reassessment, a reduction in RPN was detected with each risk. The failure mode with the second highest RPN, namely, preparation time before infusion of more than 30 minutes, was shown in detail to prove the efficiency of this tool. FMEA evaluation model is a useful tool in proactively analyzing and reducing the risks associated with the blood transfusion procedure. © 2013 American Association of Blood Banks.
Gastroduodenal Ulcers and ABO Blood Group: the Japan Nurses’ Health Study (JNHS)
Ideno, Yuki; Lee, Jung-Su; Suzuki, Shosuke; Nakajima-Shimada, Junko; Ohnishi, Hiroshi; Sato, Yasunori; Hayashi, Kunihiko
2018-01-01
Background Although several studies have shown that blood type O is associated with increased risk of peptic ulcer, few studies have investigated these associations in Japan. We sought to investigate the association between the ABO blood group and risk of gastroduodenal ulcers (GDU) using combined analysis of both retrospective and prospective data from a large cohort study of Japanese women, the Japan Nurses’ Health Study (JNHS; n = 15,019). Methods The impact of the ABO blood group on GDU risk was examined using Cox regression analysis to estimate hazard ratios (HRs) and 95% confidence intervals (CI), with adjustment for potential confounders. Results Compared with women with non-O blood types (A, B, and AB), women with blood type O had a significantly increased risk of GDU from birth (multivariable-adjusted HR 1.18; 95% CI, 1.04–1.34). Moreover, the highest cumulative incidence of GDU was observed in women born pre-1956 with blood type O. In a subgroup analysis stratified by birth year (pre-1956 or post-1955), the multivariable-adjusted HR of women with blood type O was 1.22 (95% CI, 1.00–1.49) and 1.15 (95% CI, 0.98–1.35) in the pre-1956 and post-1955 groups, respectively. Conclusion In this large, combined, ambispective cohort study of Japanese women, older women with blood type O had a higher risk of developing GDU than those with other blood types. PMID:29093357
Mass spectrometry of peptides and proteins from human blood.
Zhu, Peihong; Bowden, Peter; Zhang, Du; Marshall, John G
2011-01-01
It is difficult to convey the accelerating rate and growing importance of mass spectrometry applications to human blood proteins and peptides. Mass spectrometry can rapidly detect and identify the ionizable peptides from the proteins in a simple mixture and reveal many of their post-translational modifications. However, blood is a complex mixture that may contain many proteins first expressed in cells and tissues. The complete analysis of blood proteins is a daunting task that will rely on a wide range of disciplines from physics, chemistry, biochemistry, genetics, electromagnetic instrumentation, mathematics and computation. Therefore the comprehensive discovery and analysis of blood proteins will rank among the great technical challenges and require the cumulative sum of many of mankind's scientific achievements together. A variety of methods have been used to fractionate, analyze and identify proteins from blood, each yielding a small piece of the whole and throwing the great size of the task into sharp relief. The approaches attempted to date clearly indicate that enumerating the proteins and peptides of blood can be accomplished. There is no doubt that the mass spectrometry of blood will be crucial to the discovery and analysis of proteins, enzyme activities, and post-translational processes that underlay the mechanisms of disease. At present both discovery and quantification of proteins from blood are commonly reaching sensitivities of ∼1 ng/mL. Copyright © 2010 Wiley Periodicals, Inc.
Moloney, Gail; Hayman, Jane; Gamble, Marguerite; Smith, Geoff; Hall, Rob
2017-06-01
Retaining blood donors is a cost-effective way of ensuring a safe blood supply, yet despite the plethora of research, only 5.1% of the eligible population in Australia donate blood and 40% of these do not make a second donation. We offer an alternative to traditional approaches by conceptualizing blood donation within social representations theory as socially derived symbolic knowledge with a specific focus on cognitive polyphasia and Guimelli's (1998) normative and functional dimensions. An online survey, completed by 703 residents from NSW Australia, comprised a blood donation word association task, Likert-style questions constructed from previous word association data and contextualized blood donation statements. Individual difference scaling analysis revealed all donor groups (including non-donors) associated blood donation with a few central, albeit contradictory ideas/beliefs. Exploratory factor analysis and confirmatory factor analysis performed on a split data set of the Likert-style items reiterated this finding. Interpreted through Guimelli's dichotomy, all donor groups were aware of these contradictory normative and functional ideas/beliefs but when explicitly asked, it was the functional aspect that differentiated the groups. We argue the key to retaining donors is understanding the interdependence between how blood donation is socially understood at the societal level of discourse and donor behaviour. Translational strategies for recruitment and retention are discussed. © 2017 The British Psychological Society.
Joehanes, Roby; Johnson, Andrew D.; Barb, Jennifer J.; Raghavachari, Nalini; Liu, Poching; Woodhouse, Kimberly A.; O'Donnell, Christopher J.; Munson, Peter J.
2012-01-01
Despite a growing number of reports of gene expression analysis from blood-derived RNA sources, there have been few systematic comparisons of various RNA sources in transcriptomic analysis or for biomarker discovery in the context of cardiovascular disease (CVD). As a pilot study of the Systems Approach to Biomarker Research (SABRe) in CVD Initiative, this investigation used Affymetrix Exon arrays to characterize gene expression of three blood-derived RNA sources: lymphoblastoid cell lines (LCL), whole blood using PAXgene tubes (PAX), and peripheral blood mononuclear cells (PBMC). Their performance was compared in relation to identifying transcript associations with sex and CVD risk factors, such as age, high-density lipoprotein, and smoking status, and the differential blood cell count. We also identified a set of exons that vary substantially between participants, but consistently in each RNA source. Such exons are thus stable phenotypes of the participant and may potentially become useful fingerprinting biomarkers. In agreement with previous studies, we found that each of the RNA sources is distinct. Unlike PAX and PBMC, LCL gene expression showed little association with the differential blood count. LCL, however, was able to detect two genes related to smoking status. PAX and PBMC identified Y-chromosome probe sets similarly and slightly better than LCL. PMID:22045913
An analysis of occupational blood lead trends in Manitoba, 1979 through 1987
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yassi, A.; Cheang, M.; Tenenbein, M.
1991-06-01
While regulations for workplace lead exposure become more strict, their effectiveness in decreasing blood lead concentrations and the method by which this is attained have not been evaluated. METHODS: An analysis was conducted of 10,190 blood lead samples from employees of 10 high-risk workplaces collected in Manitoba, 1979-87, as part of regulated occupational surveillance. A significant decrease in blood lead concentrations was observed overall as well as for each individual company. A 1979 government regulation to reduce blood lead to below 3.38 mumol/L (70 micrograms/dl) was followed by a drop in blood lead concentrations; a 1983 order to reduce bloodmore » leads to below 2.90 mumol/L (60 micrograms/dl) was not followed by such a drop. Longitudinal analysis by individual workers suggested that companies were complying by use of administrative control, i.e., removing workers to lower lead areas until blood lead levels had fallen, then returning them to high lead areas. Focusing upon blood lead as the sole criterion for compliance is not effective; regulations must specifically require environmental monitoring and controls. Biological surveillance serves as 'back-up' to environmental surveillance and this database illustrates the usefulness of a comprehensive centralized surveillance system.« less
Depleted uranium analysis in blood by inductively coupled plasma mass spectrometry
Todorov, T.I.; Xu, H.; Ejnik, J.W.; Mullick, F.G.; Squibb, K.; McDiarmid, M.A.; Centeno, J.A.
2009-01-01
In this study we report depleted uranium (DU) analysis in whole blood samples. Internal exposure to DU causes increased uranium levels as well as change in the uranium isotopic composition in blood specimen. For identification of DU exposure we used the 235U/238U ratio in blood samples, which ranges from 0.00725 for natural uranium to 0.002 for depleted uranium. Uranium quantification and isotopic composition analysis were performed by inductively coupled plasma mass spectrometry. For method validation we used eight spiked blood samples with known uranium concentrations and isotopic composition. The detection limit for quantification was determined to be 4 ng L-1 uranium in whole blood. The data reproduced within 1-5% RSD and an accuracy of 1-4%. In order to achieve a 235U/238U ratio range of 0.00698-0.00752% with 99.7% confidence limit a minimum whole blood uranium concentration of 60 ng L??1 was required. An additional 10 samples from a cohort of veterans exposed to DU in Gulf War I were analyzed with no knowledge of their medical history. The measured 235U/ 238U ratios in the blood samples were used to identify the presence or absence of DU exposure within this patient group. ?? 2009 The Royal Society of Chemistry.
NASA Astrophysics Data System (ADS)
Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Karas, Oleksandr V.
2018-01-01
A fibroadenoma diagnosing of breast using statistical analysis (determination and analysis of statistical moments of the 1st-4th order) of the obtained polarization images of Jones matrix imaginary elements of the optically thin (attenuation coefficient τ <= 0,1 ) blood plasma films with further intellectual differentiation based on the method of "fuzzy" logic and discriminant analysis were proposed. The accuracy of the intellectual differentiation of blood plasma samples to the "norm" and "fibroadenoma" of breast was 82.7% by the method of linear discriminant analysis, and by the "fuzzy" logic method is 95.3%. The obtained results allow to confirm the potentially high level of reliability of the method of differentiation by "fuzzy" analysis.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakajima, K.; Bunko, H.; Tada, A.
1984-01-01
Phase analysis has been applied to Wolff-Parkinson-White syndrome (WPW) to detect the site of accessory conduction pathway (ACP); however, there was a limitation to estimate the precise location of ACP by planar phase analysis. In this study, the authors applied phase analysis to gated blood pool tomography. Twelve patients with WPW who underwent epicardial mapping and surgical division of ACP were studied by both of gated emission computed tomography (GECT) and routine gated blood pool study (GBPS). The GBPS was performed with Tc-99m red blood cells in multiple projections; modified left anterior oblique, right anterior oblique and/or left lateral views.more » In GECT, short axial, horizontal and vertical long axial blood pool images were reconstructed. Phase analysis was performed using fundamental frequency of the Fourier transform in both GECT and GBPS images, and abnormal initial contractions on both the planar and tomographic phase analysis were compared with the location of surgically confirmed ACPs. In planar phase analysis, abnormal initial phase was identified in 7 out of 12 (58%) patients, while in tomographic phase analysis, the localization of ACP was predicted in 11 out of 12 (92%) patients. Tomographic phase analysis is superior to planar phase images in 8 out of 12 patients to estimate the location of ACP. Phase analysis by GECT can avoid overlap of blood pool in cardiac chambers and has advantage to identify the propagation of phase three-dimensionally. Tomographic phase analysis is a good adjunctive method for patients with WPW to estimate the site of ACP.« less
Study of Blood-transfusion Services in Maharashtra and Gujarat States, India
Ramani, K.V.; Govil, Dipti
2009-01-01
Blood-transfusion services are vital to maternal health because haemorrhage and anaemia are major causes of maternal death in South Asia. Unfortunately, due to continued governmental negligence, blood-transfusion services in India are a highly-fragmented mix of competing independent and hospital-based blood-banks, serving the needs of urban populations. This paper aims to understand the existing systems of blood-transfusion services in India focusing on Maharashtra and Gujarat states. A mix of methodologies, including literature review (including government documents), analysis of management information system data, and interviews with key officials was used. Results of analysis showed that there are many managerial challenges in blood-transfusion services, which calls for strengthening the planning and monitoring of these services. Maharashtra provides a good model for improvement. Unless this is done, access to blood in rural areas may remain poor. PMID:19489420
Analysis of pediatric blood lead levels in New York City for 1970-1976.
Billick, I H; Curran, A S; Shier, D R
1979-01-01
A study was completed of more than 170,000 records of pediatric venous blood levels and supporting demographic information collected in New York City during 1970-1976. The geometric mean (GM) blood lead level shows a consistent cyclical variation superimposed on an overall decreasing trend with time for all ages and ethnic groups studied. The GM blood lead levels for blacks are significantly greater than those for either Hispanics or whites. Regression analysis indicates a significant statistical association between GM blood lead level and ambient air lead level, after appropriate adjustments are made for age and ethnic group. These highly significant statistical relationships provide extremely strong incentives and directions for research into casual factors related to blood lead levels in children. PMID:499123
Diagnostic Application of Absolute Neutron Activation Analysis in Hematology
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zamboni, C.B.; Oliveira, L.C.; Dalaqua, L. Jr.
2004-10-03
The Absolute Neutron Activation Analysis (ANAA) technique was used to determine element concentrations of Cl and Na in blood of healthy group (male and female blood donators), select from Blood Banks at Sao Paulo city, to provide information which can help in diagnosis of patients. This study permitted to perform a discussion about the advantages and limitations of using this nuclear methodology in hematological examinations.
Grubb, D; Rasmussen, B; Linnet, K; Olsson, S G; Lindberg, L
2012-03-10
A novel breath-alcohol analyzer based on the standardization of the breath alcohol concentration (BrAC) to the alveolar-air water vapour concentration has been developed and evaluated. The present study compares results with this particular breath analyzer with arterial blood alcohol concentrations (ABAC), the most relevant quantitative measure of brain alcohol exposure. The precision of analysis of alcohol in arterial blood and breath were determined as well as the agreement between ABAC and BrAC over time post-dosing. Twelve healthy volunteers were administered 0.6g alcohol/kg bodyweight via an orogastric tube. Duplicate breath and arterial blood samples were obtained simultaneously during the absorption, distribution and elimination phases of the alcohol metabolism with particular emphasis on the absorption phase. The precision of the breath analyzer was similar to the determination of blood alcohol concentration by headspace gas chromatography (CV 2.40 vs. 2.38%, p=0.43). The ABAC/BrAC ratio stabilized 30min post-dosing (2089±99; mean±SD). Before this the BrAC tended to underestimate the coexisting ABAC. In conclusion, breath alcohol analysis utilizing standardization of alcohol to water vapour was as precise as blood alcohol analysis, the present "gold standard" method. The BrAC reliably predicted the coexisting ABAC from 30min onwards after the intake of alcohol. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.
Chivukula, V; Mousel, J; Lu, J; Vigmostad, S
2014-12-01
The current research presents a novel method in which blood particulates - biconcave red blood cells (RBCs) and spherical cells are modeled using isogeometric analysis, specifically Non-Uniform Rational B-Splines (NURBS) in 3-D. The use of NURBS ensures that even with a coarse representation, the geometry of the blood particulates maintains an accurate description when subjected to large deformations. The fundamental advantage of this method is the coupling of the geometrical description and the stress analysis of the cell membrane into a single, unified framework. Details on the modeling approach, implementation of boundary conditions and the membrane mechanics analysis using isogeometric modeling are presented, along with validation cases for spherical and biconcave cells. Using NURBS - based isogeometric analysis, the behavior of individual cells in fluid flow is presented and analyzed in different flow regimes using as few as 176 elements for a spherical cell and 220 elements for a biconcave RBC. This work provides a framework for modeling a large number of 3-D deformable biological cells, each with its own geometric description and membrane properties. To the best knowledge of the authors, this is the first application of the NURBS - based isogeometric analysis to model and simulate blood particulates in flow in 3D. Copyright © 2014 John Wiley & Sons, Ltd.
Zhu, Pengli; Huang, Feng; Lin, Fan; Yuan, Yin; Chen, Falin; Li, Qiaowei
2013-11-01
To describe the relationship of plasma apelin levels with blood pressure in a coastal Chinese population. This cross-sectional study included a total of 1031 subjects from the coastal areas of China. One-way analysis of variance (ANOVA) and linear trend test, Pearson's correlation analysis, as well as multivariate linear regression analysis were used to evaluate the association between plasma apelin levels and blood pressure. Plasma apelin levels dropped with increasing quartiles of systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial blood pressure (MABP) (all P<0.001). SBP, DBP, and MABP values decreased as the apelin levels increased within the quartiles. After adjusting for age and gender, the significant differences in SBP, DBP, and MABP between the groups within the apelin quartiles remained (all P<0.05). A significant negative correlation between SBP, DBP, as well as MABP and apelin levels was observed (all P<0.01); even after adjusting for cardiovascular confounding factors, this negative correlation remained (all P<0.001). A negative correlation between plasma apelin levels and blood pressure was found in this 1000-population-based epidemiological study. Apelin may become a potential therapeutic target of anti-hypertensive treatment.
NASA Astrophysics Data System (ADS)
Ogruc Ildiz, G.; Arslan, M.; Unsalan, O.; Araujo-Andrade, C.; Kurt, E.; Karatepe, H. T.; Yilmaz, A.; Yalcinkaya, O. B.; Herken, H.
2016-01-01
In this study, a methodology based on Fourier-transform infrared spectroscopy and principal component analysis and partial least square methods is proposed for the analysis of blood plasma samples in order to identify spectral changes correlated with some biomarkers associated with schizophrenia and bipolarity. Our main goal was to use the spectral information for the calibration of statistical models to discriminate and classify blood plasma samples belonging to bipolar and schizophrenic patients. IR spectra of 30 samples of blood plasma obtained from each, bipolar and schizophrenic patients and healthy control group were collected. The results obtained from principal component analysis (PCA) show a clear discrimination between the bipolar (BP), schizophrenic (SZ) and control group' (CG) blood samples that also give possibility to identify three main regions that show the major differences correlated with both mental disorders (biomarkers). Furthermore, a model for the classification of the blood samples was calibrated using partial least square discriminant analysis (PLS-DA), allowing the correct classification of BP, SZ and CG samples. The results obtained applying this methodology suggest that it can be used as a complimentary diagnostic tool for the detection and discrimination of these mental diseases.
Ernst, D; Clerc, J; Decullier, E; Gavanier, G; Dupuis, O
2012-10-01
At birth, evaluation of neonatal well-being is crucial. It is though important to perform umbilical cord blood gas analysis, and then to analyze the samples. We wanted to establish the feasibility and reliability of systematic umbilical cord blood sampling in a French labour ward. Study of systematic umbilical cord blood gas analysis was realized retrospectively from 1000 consecutive deliveries. We first established the feasibility of the samples. Feasibility was defined by the ratio of complete cord acid-base data on the number of deliveries from alive newborns. Afterwards, we established the reliability on the remaining cord samples. Reliability was the ratio of samples that fulfilled quality criteria defined by Westgate et al. and revised by Kro et al., on the number of complete samples from alive newborns. At last, we looked for factors that would influence these results. The systematic umbilical cord blood sample feasibility reached 91.6%, and the reliability reached 80.7%. About the delivery mode, 38.6% of emergency caesarians (IC 95% [30.8-46.3]; P<0.0001) led to non-valid samples, when only 11.3% of programmed caesarians (IC 95% [4.3-18.2]; P<0.0001) led to non-valid samples. Umbilical cord blood analysis were significantly less validated during emergency caesarians. Realization of systematic cord blood gas analysis was followed by 8.4% of incomplete samples, and by 19.3% that were uninterpretable. Training sessions should be organized to improve the feasibility and reliability, especially during emergency caesarians. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
Use of cost-effectiveness analysis to determine inventory size for a national cord blood bank.
Howard, David H; Meltzer, David; Kollman, Craig; Maiers, Martin; Logan, Brent; Gragert, Loren; Setterholm, Michelle; Horowitz, Mary M
2008-01-01
Transplantation with stem cells from stored umbilical cord blood units is an alternative to living unrelated bone marrow transplantation. The larger the inventory of stored cord units, the greater the likelihood that transplant candidates will match to a unit, but storing units is costly. The authors present the results of a study, commissioned by the Institute of Medicine, as part of a report on the establishment of a national cord blood bank, examining the optimal inventory level. They emphasize the unique challenges of undertaking cost-effectiveness analysis in this field and the contribution of the analysis to policy. The authors estimate the likelihood that transplant candidates will match to a living unrelated marrow donor or a cord blood unit as a function of cord blood inventory and then calculate the life-years gained for each transplant type by match level using historical data. They develop a model of the cord blood inventory level to estimate total costs as a function of the number of stored units. The cost per life-year gained associated with increasing inventory from 50,000 to 100,000 units is $44,000 to $86,000 and from 100,000 to 150,000 units is $64,000 to $153,000, depending on the assumption about the degree to which survival rates for cord transplants vary by match quality. Expanding the cord blood inventory above current levels is cost-effective by conventional standards. The analysis helped shape the Institute of Medicine's report, but it is difficult to determine the extent to which the analysis influenced subsequent congressional legislation.
Kaewkamnerd, Saowaluck; Uthaipibull, Chairat; Intarapanich, Apichart; Pannarut, Montri; Chaotheing, Sastra; Tongsima, Sissades
2012-01-01
Current malaria diagnosis relies primarily on microscopic examination of Giemsa-stained thick and thin blood films. This method requires vigorously trained technicians to efficiently detect and classify the malaria parasite species such as Plasmodium falciparum (Pf) and Plasmodium vivax (Pv) for an appropriate drug administration. However, accurate classification of parasite species is difficult to achieve because of inherent technical limitations and human inconsistency. To improve performance of malaria parasite classification, many researchers have proposed automated malaria detection devices using digital image analysis. These image processing tools, however, focus on detection of parasites on thin blood films, which may not detect the existence of parasites due to the parasite scarcity on the thin blood film. The problem is aggravated with low parasitemia condition. Automated detection and classification of parasites on thick blood films, which contain more numbers of parasite per detection area, would address the previous limitation. The prototype of an automatic malaria parasite identification system is equipped with mountable motorized units for controlling the movements of objective lens and microscope stage. This unit was tested for its precision to move objective lens (vertical movement, z-axis) and microscope stage (in x- and y-horizontal movements). The average precision of x-, y- and z-axes movements were 71.481 ± 7.266 μm, 40.009 ± 0.000 μm, and 7.540 ± 0.889 nm, respectively. Classification of parasites on 60 Giemsa-stained thick blood films (40 blood films containing infected red blood cells and 20 control blood films of normal red blood cells) was tested using the image analysis module. By comparing our results with the ones verified by trained malaria microscopists, the prototype detected parasite-positive and parasite-negative blood films at the rate of 95% and 68.5% accuracy, respectively. For classification performance, the thick blood films with Pv parasite was correctly classified with the success rate of 75% while the accuracy of Pf classification was 90%. This work presents an automatic device for both detection and classification of malaria parasite species on thick blood film. The system is based on digital image analysis and featured with motorized stage units, designed to easily be mounted on most conventional light microscopes used in the endemic areas. The constructed motorized module could control the movements of objective lens and microscope stage at high precision for effective acquisition of quality images for analysis. The analysis program could accurately classify parasite species, into Pf or Pv, based on distribution of chromatin size.
Debey-Pascher, Svenja; Hofmann, Andrea; Kreusch, Fatima; Schuler, Gerold; Schuler-Thurner, Beatrice; Schultze, Joachim L.; Staratschek-Jox, Andrea
2011-01-01
Microarray-based transcriptome analysis of peripheral blood as surrogate tissue has become an important approach in clinical implementations. However, application of gene expression profiling in routine clinical settings requires careful consideration of the influence of sample handling and RNA isolation methods on gene expression profile outcome. We evaluated the effect of different sample preservation strategies (eg, cryopreservation of peripheral blood mononuclear cells or freezing of PAXgene-stabilized whole blood samples) on gene expression profiles. Expression profiles obtained from cryopreserved peripheral blood mononuclear cells differed substantially from those of their nonfrozen counterpart samples. Furthermore, expression profiles in cryopreserved peripheral blood mononuclear cell samples were found to undergo significant alterations with increasing storage period, whereas long-term freezing of PAXgene RNA stabilized whole blood samples did not significantly affect stability of gene expression profiles. This report describes important technical aspects contributing toward the establishment of robust and reliable guidance for gene expression studies using peripheral blood and provides a promising strategy for reliable implementation in routine handling for diagnostic purposes. PMID:21704280
Wu, Yuangang; Yang, Timin; Zeng, Yi; Si, Haibo; Li, Canfeng; Shen, Bin
2017-01-01
Postoperative limb positioning has been reported to be an efficient and simple way to reduce blood loss and improve range of motion following total knee arthroplasty (TKA). This meta-analysis was designed to compare the effectiveness of two different limb positions in primary TKA. A meta-analysis of the PubMed, CENTRAL, Web of Science, EMBASE and Google Search Engine electronic databases was performed. In this meta-analysis, two postoperative limb positions were considered: mild-flexion (flexion less than 60°) and high-flexion (flexion at 60° or more). The subgroups were analysed using RevMan 5.3. Nine RCTs were included with a total sample size of 913 patients. The mild- and high-flexion positions significantly reduced postoperative total blood loss (P = 0.04 and P = 0.01; respectively). Subgroup analysis indicated that knee flexion significantly reduced hidden blood loss when the knee was fixed in mild-flexion (P = 0.0004) and significantly reduced transfusion requirements (P = 0.03) and improved range of motion (ROM) (P < 0.00001) when the knee was fixed in high-flexion. However, the rates of wound-related infection, deep venous thrombosis (DVT) and pulmonary embolism (PE) did not significantly differ between the two flexion groups. This meta-analysis suggests that mild- and high-flexion positions have similar efficacy in reducing total blood loss. In addition, subgroup analysis indicates that the mild-flexion position is superior in decreasing hidden blood loss compared with high-flexion; the high-flexion position is superior to mild-flexion in reducing transfusion requirements and improving postoperative ROM. Thus, the use of the high-flexion position is a viable option to reduce blood loss in patients following primary TKA without increasing the risk of wound-related infection, DVT or PE. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Weightlifting: Bad for Your Blood Pressure?
... blood pressure: A systematic review and meta-analysis. Journal of the American Heart Association. 2013;2:e004473. Getting active to control high blood pressure. American Heart Association. http://www.heart.org/HEARTORG/ ...
Automated Prediction of Early Blood Transfusion and Mortality in Trauma Patients
2014-09-24
We hypothesized that analysis of pulse oximeter signals could predict blood transfusion and mortality as accurately as conventional vital signs(VSs...to 3-hour transfusion, MT, and mortality no differently from pulse oximeter signals alone. Pulse oximeter features collected in the first 15 minutes...time is an unrealized goal. We hypothesized that analysis of pulse oximeter signals could predict blood transfusion and mortality as accurately as
Real Time Intraoperative Monitoring of Blood Loss with a Novel Tablet Application
Sharareh, Behnam; Woolwine, Spencer; Satish, Siddarth; Abraham, Peter; Schwarzkopf, Ran
2015-01-01
Introduction : Real-time monitoring of blood loss is critical in fluid management. Visual estimation remains the standard of care in estimating blood loss, yet is demonstrably inaccurate. Photometric analysis, which is the referenced “gold-standard” for measuring blood loss, is both time-consuming and costly. The purpose of this study was to evaluate the efficacy of a novel tablet-monitoring device for measurement of Hb loss during orthopaedic procedures. Methods : This is a prospective study of 50 patients in a consecutive series of joint arthroplasty cases. The novel System with Feature Extraction Technology was used to measure the amount of Hb contained within surgical sponges intra-operatively. The system’s measures were then compared with those obtained via gravimetric method and photometric analysis. Accuracy was evaluated using linear regression and Bland-Altman analysis. Results : Our results showed a significant positive correlation between Triton tablet system and photometric analysis with respect to intra-operative hemoglobin and blood loss at 0.92 and 0.91, respectively. Discussion : This novel system can accurately determine Hb loss contained within surgical sponges. We believe that this user-friendly software can be used for measurement of total intraoperative blood loss and thus aid in a more accurate fluid management protocols during orthopaedic surgical procedures. PMID:26401167
Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan
2015-01-01
Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P < 0.0001), and platelet concentrate (MD: -10.66; 95% CI: -18.45 to -2.87; P = 0.007), and had a lower re-exploration rate (RR: 0.46; 95% CI: 0.23 to 0.92; P = 0.03). Prophylactic EACA also improved coagulation tests 6 hours after open-heart surgery. Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the prevention of postoperative blood transfusion following pediatric cardiac surgery.
NASA Astrophysics Data System (ADS)
Marguí, E.; Queralt, I.; García-Ruiz, E.; García-González, E.; Rello, L.; Resano, M.
2018-01-01
Home-based collection protocols for clinical specimens are actively pursued as a means of improving life quality of patients. In this sense, dried blood spots (DBS) are proposed as a non-invasive and even self-administered alternative to sampling whole venous blood. This contribution explores the potential of energy dispersive X-ray fluorescence spectrometry for the simultaneous and direct determination of some major (S, Cl, K, Na), minor (P, Fe) and trace (Ca, Cu, Zn) elements in blood, after its deposition onto clinical filter papers, thus giving rise to DBS. For quantification purposes the best strategy was to use matrix-matched blood samples of known analyte concentrations. The accuracy and precision of the method were evaluated by analysis of a blood reference material (Seronorm™ trace elements whole blood L3). Quantitative results were obtained for the determination of P, S, Cl, K and Fe, and limits of detection for these elements were adequate, taking into account their typical concentrations in real blood samples. Determination of Na, Ca, Cu and Zn was hampered by the occurrence of high sample support (Na, Ca) and instrumental blanks (Cu, Zn). Therefore, the quantitative determination of these elements at the levels expected in blood samples was not feasible. The methodology developed was applied to the analysis of several blood samples and the results obtained were compared with those reported by standard techniques. Overall, the performance of the method developed is promising and it could be used to determine the aforementioned elements in blood samples in a simple, fast and economic way. Furthermore, its non-destructive nature enables further analyses by means of complementary techniques to be carried out.
[Experimental research and analysis on dielectric properties of blood in anemia mice].
Shen, Ben; Liang, Quiyan; Gao, Weiqi; You, Chu; Hong, Mengqi; Ma, Qing
2013-12-01
The conductivity and permittivity of blood in mice were measured by the AC electrical impedance method at frequency range of 0.1-100MHz, and then the changes of the Cole-Cole parameters of dielectric spectra of blood from phenylhydrazine-induced anemia mice were observed by numerical calculation and curve fitting residual analysis of the Cole-Cole equation. The results showed that hematocrit (Hct) of the mice with phenylhydrazine injection was significantly reduced; the permittivity(epsilon) spectroscopy of blood moved to the low insulating region and its permittivity decreased; conductivity (kappa) spectrum curve of blood moved to the high conductivity zone and conductivity increased; the 2nd characteristic frequency was lower than that in the normal group. There was phenylhydrazine dose dependent in the changes of the Cole-Cole parameters of dielectric spectra of blood.
Blood vitamin C levels of motorized tricycle drivers in Parañaque, Philippines.
Sia Su, Glenn L; Kayali, Sara
2008-08-01
Vitamin C is an essential micronutrient maintaining the state of well being of individuals. This study examined factors affecting and the blood vitamin C levels of motorized tricycle drivers in Parañaque City, Philippines. Consenting drivers (N=49) were included in the study and were assessed through self-administered questionnaires, 24-h food recalls, and anthropometric measurements and on the analysis of their blood vitamin C levels. Factors related to the blood vitamin C levels of the motorized tricycle drivers were determined by correlation analysis. Majority (79.6%) of drivers had low blood vitamin C levels. Workplace and vitamin C supplementations (p<0.05) were significantly related to the blood vitamin C levels of the motorized tricycle drivers. Further studies are recommended to understand the problem and the determinants of vitamin C deficiency among the general population.
Analysis of skin blood microflow oscillations in patients with rheumatic diseases
NASA Astrophysics Data System (ADS)
Mizeva, Irina; Makovik, Irina; Dunaev, Andrey; Krupatkin, Alexander; Meglinski, Igor
2017-07-01
Laser Doppler flowmetry (LDF) has been applied for the assessment of variation in blood microflows in patients with rheumatic diseases and healthy volunteers. Oscillations of peripheral blood microcirculation observed by LDF have been analyzed utilizing a wavelet transform. A higher amplitude of blood microflow oscillations has been observed in a high frequency band (over 0.1 Hz) in patients with rheumatic diseases. Oscillations in the high frequency band decreased in healthy volunteers in response to the cold pressor test, whereas lower frequency pulsations prevailed in patients with rheumatic diseases. A higher perfusion rate at normal conditions was observed in patients, and a weaker response to cold stimulation was observed in healthy volunteers. Analysis of blood microflow oscillations has a high potential for evaluation of mechanisms of blood flow regulation and diagnosis of vascular abnormalities associated with rheumatic diseases.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-10-15
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard - fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline - second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing.
Dukić, Lora; Kopčinović, Lara Milevoj; Dorotić, Adrijana; Baršić, Ivana
2016-01-01
Blood gas analysis (BGA) is exposed to risks of errors caused by improper sampling, transport and storage conditions. The Clinical and Laboratory Standards Institute (CLSI) generated documents with recommendations for avoidance of potential errors caused by sample mishandling. Two main documents related to BGA issued by the CLSI are GP43-A4 (former H11-A4) Procedures for the collection of arterial blood specimens; approved standard – fourth edition, and C46-A2 Blood gas and pH analysis and related measurements; approved guideline – second edition. Practices related to processing of blood gas samples are not standardized in the Republic of Croatia. Each institution has its own protocol for ordering, collection and analysis of blood gases. Although many laboratories use state of the art analyzers, still many preanalytical procedures remain unchanged. The objective of the Croatian Society of Medical Biochemistry and Laboratory Medicine (CSMBLM) is to standardize the procedures for BGA based on CLSI recommendations. The Working Group for Blood Gas Testing as part of the Committee for the Scientific Professional Development of the CSMBLM prepared a set of recommended protocols for sampling, transport, storage and processing of blood gas samples based on relevant CLSI documents, relevant literature search and on the results of Croatian survey study on practices and policies in acid-base testing. Recommendations are intended for laboratory professionals and all healthcare workers involved in blood gas processing. PMID:27812301
HEMORHEOLOGY INDEX CHANGES IN A RAT ACUTE BLOOD STASIS MODEL: A SYSTEMATIC REVIEW AND META-ANALYSIS
Zhang, Jun-Xiu; Feng, Yu; Zhang, Yin; Liu, Yi; Li, Shao-Dan; Yang, Ming-Hui
2017-01-01
Background: Blood stasis has received increasing attention in research related to traditional Chinese medicine (TCM) and integrative Chinese and Western medicine. More than 90% of research studies use hemorheology indexes to evaluate the establishment of animal blood stasis models rather than pathological methods, as hemorheology index evaluations of blood stasis were short of the consolidated standard. The aim of this study was to evaluate the accuracy of hemorheology indexes in rat models of acute blood stasis (ABS) based on studies in which the ABS model had been confirmed by pathological methods. Materials and Methods: We searched the Chinese National Knowledge Infrastructure database (CNKI), Chinese Medical Journal Database (CMJD), Chinese Biology Medicine disc (CBM), Wanfang database, and PubMed for studies of rat blood stasis models; the search identified 18 studies of rat ABS models induced by subcutaneous injection of epinephrine combined with an ice bath. Each included study received a modified Collaborative Approach to Meta-Analysis and Review of Animal Data from Experimental Studies (CAMARADES) score list and methodological quality assessment, then data related to whole blood viscosity, plasma viscosity, platelet aggregation rate, erythrocyte aggregation index, and fibrinogen concentration were extracted. Extracted data were analyzed using Revman 5.3; heterogeneity was tested using Egger’s test. Results: A total of 343 studies of rat blood stasis were reviewed. Eighteen studies were included in this meta-analysis; the mean CAMARADES score was 3.5. The rat ABS model revealed a significant increase in whole blood viscosity (medium shear rate), whole blood viscosity (high shear rate), plasma viscosity, platelet aggregation rate, erythrocyte aggregation index, and fibrinogen concentration compared to controls, with weighted mean differences (WMD) of 2.42 mPa/s (95% confidence interval (CI) = 1.73 - 3.10); 1.76 mPa/s (95% CI = 1.28 - 2.24); 0.39 mPa/s (95% CI = 0.24 - 0.55); 13.66% (95% CI = 9.78 - 17.55); 0.84 (95% CI = 0.53 - 1.16); and 1.22 g/L (95% CI = 0.76 - 1.67), respectively. Subgroup analysis showed that whole blood viscosity, plasma viscosity, and the platelet aggregation rate test methods were more sensitive when measured at 0-24 h than at 24-72 h after induction of blood stasis. Conclusions: Rat blood stasis studies have incomplete experimental design and quality controls, and thus need an integrated improvement. Meta-analysis of included studies indicated that the unified hemorheology index of whole blood viscosity (medium and high shear rate), platelet aggregation rate, erythrocyte aggregation rate, and fibrinogen concentration might be used for assessment of rat ABS models independent of pathology methods. PMID:28638872
Determinants of hydroxychloroquine blood concentration variations in systemic lupus erythematosus.
Jallouli, M; Galicier, L; Zahr, N; Aumaître, O; Francès, C; Le Guern, V; Lioté, F; Smail, A; Limal, N; Perard, L; Desmurs-Clavel, H; Le Thi Huong, D; Asli, B; Kahn, J-E; Pourrat, J; Sailler, L; Ackermann, F; Papo, T; Sacré, K; Fain, O; Stirnemann, J; Cacoub, P; Leroux, G; Cohen-Bittan, J; Sellam, J; Mariette, X; Blanchet, B; Hulot, J S; Amoura, Z; Piette, J C; Costedoat-Chalumeau, N
2015-05-01
Blood concentrations of hydroxychloroquine (HCQ) vary widely among patients with systemic lupus erythematosus (SLE). A pharmacokinetic/pharmacodynamic relationship has been found in different situations, and a very low blood concentration of HCQ is a simple marker of nonadherence to treatment. Therefore, interest in blood HCQ concentration measurement has increased, but little is known about factors that influence blood HCQ concentration variability. This study was undertaken to analyze determinants of blood HCQ concentrations. We conducted a retrospective analysis of patient data, including data from the Plaquenil Lupus Systemic (PLUS) study, to determine the association of epidemiologic, clinical, and biologic factors with blood HCQ concentrations. Data for nonadherent patients (blood HCQ concentration <200 ng/ml) were excluded. To examine homogeneous pharmacologic data, we restricted the analyses of the PLUS data to the 509 SLE patients receiving 400 mg/day. We found no association of ethnicity or smoking with blood HCQ concentrations and no pharmacokinetic drug-drug interaction with antacids or with inhibitors or inducers of cytochrome P450 enzymes. On multivariate analysis, high body mass index (P = 0.008), no treatment with corticosteroids (P = 0.04), increased time between the last tablet intake and measurement of blood HCQ concentrations (P = 0.017), low platelet count (P < 0.001), low neutrophil count (P < 0.001), and high estimated creatinine clearance (P < 0.001) were associated with low blood HCQ concentrations. In 22 SLE patients with chronic renal insufficiency (median serum creatinine clearance 52 ml/minute [range 23-58 ml/minute]) who received 400 mg/day HCQ, the median blood HCQ concentration was significantly higher than that in the 509 patients from the PLUS study (1,338 ng/ml [range 504-2,229 ng/ml] versus 917 ng/ml [range 208-3316 ng/ml]) (P < 0.001). We provide a comprehensive analysis of determinants of blood HCQ concentrations. Because this measurement is increasingly being used, these data might be useful for clinicians. © 2015, American College of Rheumatology.
NASA Astrophysics Data System (ADS)
Metairon, S.; Zamboni, C. B.; Suzuki, M. F.; Júnior, C. R. B.; Sant'Anna, O. A.
2011-08-01
The Br, Ca, Cl, K, Na and S concentrations in whole blood of DMDmdx/J and C57BL/6J mice were determined using Neutron Activation Analysis technique. Reference values obtained from twenty one whole blood samples of these strains were analyzed in the IEA-R1 nuclear reactor at IPEN (São Paulo, Brasil). These data contribute for applications in veterinary medicine related to biochemistry analyses using whole blood as well as to evaluate the performance of treatments in muscular dystrophy.
Chung, Jun-Young; Ogawa, Seiji
2015-01-01
The fusiform face area (FFA) is known to play a pivotal role in face processing. The FFA is located in the ventral region, at the base of the brain, through which large blood vessels run. The location of the FFA via functional MRI (fMRI) may be influenced by these large blood vessels. Responses of large blood vessels may not exactly correspond to neuronal activity in a target area, because they may be diluted and influenced by inflow effects. In this study, we investigated the effects of large blood vessels in the FFA, that is, whether the FFA includes large blood vessels and/or whether inflow signals contribute to fMRI signals of the FFA. For this purpose, we used susceptibility-weighted imaging (SWI) sequences to visualize large blood vessels and dual-echo gradient-echo echo-planar imaging (GE-EPI) to measure inflow effects. These results showed that the location and response signals of the FFA were not influenced by large blood vessels or inflow effects, although large blood vessels were located near the FFA. Therefore, the data from the FFA obtained by individual analysis were robust to large blood vessels but leaving a warning that the data obtained by group analysis may be prone to large blood vessels. PMID:26413511
Ploner, Stefan B; Moult, Eric M; Choi, WooJhon; Waheed, Nadia K; Lee, ByungKun; Novais, Eduardo A; Cole, Emily D; Potsaid, Benjamin; Husvogt, Lennart; Schottenhamml, Julia; Maier, Andreas; Rosenfeld, Philip J; Duker, Jay S; Hornegger, Joachim; Fujimoto, James G
2016-12-01
Currently available optical coherence tomography angiography systems provide information about blood flux but only limited information about blood flow speed. The authors develop a method for mapping the previously proposed variable interscan time analysis (VISTA) algorithm into a color display that encodes relative blood flow speed. Optical coherence tomography angiography was performed with a 1,050 nm, 400 kHz A-scan rate, swept source optical coherence tomography system using a 5 repeated B-scan protocol. Variable interscan time analysis was used to compute the optical coherence tomography angiography signal from B-scan pairs having 1.5 millisecond and 3.0 milliseconds interscan times. The resulting VISTA data were then mapped to a color space for display. The authors evaluated the VISTA visualization algorithm in normal eyes (n = 2), nonproliferative diabetic retinopathy eyes (n = 6), proliferative diabetic retinopathy eyes (n = 3), geographic atrophy eyes (n = 4), and exudative age-related macular degeneration eyes (n = 2). All eyes showed blood flow speed variations, and all eyes with pathology showed abnormal blood flow speeds compared with controls. The authors developed a novel method for mapping VISTA into a color display, allowing visualization of relative blood flow speeds. The method was found useful, in a small case series, for visualizing blood flow speeds in a variety of ocular diseases and serves as a step toward quantitative optical coherence tomography angiography.
Blood specimen labelling errors: Implications for nephrology nursing practice.
Duteau, Jennifer
2014-01-01
Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.
Han, Hedong; Zhang, Tianyi; Jin, Zhichao; Guo, Honglei; Wei, Xin; Liu, Yuzhou; Chen, Qi; He, Jia
2017-07-25
The question of whether elevated blood glucose is a risk factor for liver cancer has been intensively studied, yet with inconsistent results. To explore the relationship between blood glucose concentration and risk of liver cancer, we conduct a meta-analysis of prospective studies. Literature search was comprehensively performed using database of PubMed, EMBASE and the Cochrane Library through October 2016. Random-effect models were used to combine the effect estimations. Eight articles containing ten studies with a total of 1975 liver cancer cases were included. The pooled RRs demonstrated that elevated fasting blood glucose was associated with increased risk of liver cancer (combined RRs: 1.77; 95% CI: 1.46, 2.13) with mild heterogeneity (I2 = 30.40%, P = 0.17). In sensitivity analysis, the pooled result remained significant (combined RRs: 1.33; 95% CI: 1.12, 1.59; I2 = 33.90%, P = 0.16) when we restricted blood glucose categories in the range of nondiabetic subjects. We also detected a J-shaped non-linear dose-response relationship between blood glucose concentration and risk of liver cancer. There is evidence that elevated blood glucose increases risk of liver cancer across the range of prediabetes and diabetes. Considering the rapidly increasing prevalence of prediabetes and diabetes, controlling blood glucose may lower the risk of liver cancer.
Pancreatic Cystic Fluid Reference Set — EDRN Public Portal
The proposed reference set will be designed to evaluate biomarkers for the following applications aimed at determining whether a patient would benefit from surgical resection of their cystic lesion: 1. Distinguish between pancreatic cysts that have high-malignant potential and cysts that have low or no malignant potential at time of endoscopic ultrasound evaluation. a. By analysis of blood b. By analysis of pancreatic cystic fluid 2. Distinguish between cysts that have any malignant potential (high and low) and cysts that have no malignant potential (benign lesions) at time of endoscopic ultrasound evaluation. a. By analysis of blood b. By analysis of pancreatic cystic fluid 3. Distinguish between a cyst that is mucinous (malignant potential) or non-mucinous (no malignant potential) at time of endoscopic ultrasound evaluation. a. By analysis of blood b. By analysis of pancreatic cystic fluid 4. Distinguish between pancreatic cysts that have high-malignant potential and cysts that have low or no malignant potential at time of evaluation in surgery clinic. a. By analysis of blood 5. Distinguish between cysts that have any malignant potential (high and low) and cysts that have no malignant potential (benign lesions) at time of evaluation in surgery clinic. a. By analysis of blood 6. Distinguish between a cyst that is mucinous (malignant potential) or non-mucinous (no malignant potential) at time of evaluation in surgery clinic. a. By analysis of blood If successful in meeting these afore-mentioned objectives, these results can then be used in the development of future studies at identifying the need for additional evaluation (i.e., endoscopic ultrasound with fine needle aspiration) of an incidental cyst
2013-01-01
Background Genotyping requires biological sample collection that must be reliable, convenient and acceptable for patients and clinicians. Finding the most optimal procedure of sample collection for premature neonates who have a very limited blood volume is a particular challenge. The aim of the current study was to evaluate the use of umbilical cord (UC) tissue and newborn dried blood spot (DBS)-extracted genomic DNA (gDNA) as an alternative to venous blood-derived gDNA from premature neonates for molecular genetic analysis. All samples were obtained from premature newborn infants between 24-32 weeks of gestation. Paired blood and UC samples were collected from 31 study participants. gDNA was extracted from ethylenediaminetetraacetic acid (EDTA) anticoagulant-treated blood samples (~500 μl) and newborn DBSs (n = 723) using QIAamp DNA Micro kit (Qiagen Ltd., Crawley, UK); and from UC using Qiagen DNAeasy Blood and Tissue kit (Qiagen Ltd., Crawley, UK). gDNA was quantified and purity confirmed by measuring the A260:A280 ratio. PCR amplification and pyrosequencing was carried out to determine suitability of the gDNA for molecular genetic analysis. Minor allele frequency of two unrelated single nucleotide polymorphisms (SNPs) was calculated using the entire cohort. Results Both whole blood samples and UC tissue provided good quality and yield of gDNA, which was considerably less from newborn DBS. The gDNA purity was also reduced after 3 years of storage of the newborn DBS. PCR amplification of three unrelated genes resulted in clear products in all whole blood and UC samples and 86%-100% of newborn DBS. Genotyping using pyrosequencing showed 100% concordance in the paired UC and whole blood samples. Minor allele frequencies of the two SNPs indicated that no maternal gDNA contamination occurred in the genotyping of the UC samples. Conclusions gDNAs from all three sources are suitable for standard PCR and pyrosequencing assays. Given that UC provide good quality and quantity gDNA with 100% concordance in the genetic analysis with whole blood, it can replace blood sampling from premature infants. This is likely to reduce the stress and potential side effects associated with invasive sample collection and thus, greatly facilitate participant recruitment for genetic studies. PMID:24168095
Morphological analysis of red blood cells by polychromatic interference microscopy of thin films
NASA Astrophysics Data System (ADS)
Dyachenko, A. A.; Malinova, L. I.; Ryabukho, V. P.
2016-11-01
Red blood cells (RBC) distribution width (RDW) is a promising hematological parameter with broadapplications in clinical practice; in various studies RDWhas been shown to be associated with increased risk of heart failure (HF) in general population. It predicts mortality and other major adverse events in HF patients. In this report new method of RDWmeasurement is presented. It's based on interference color analysis of red blood cells in blood smear and further measurement of its optical thickness. Descriptive statistics of the of the RBC optical thickness distribution in a blood smear were used for RDW estimation in every studied sample. Proposed method is considered to be avoiding type II errors and minimizing the variability of measured RDW.
Distler, Jurgen; Tetzner, Reimo; Weiss, Gunter; König, Thomas; Schlegel, Anne; Bagrowski, Michal
2016-01-01
For the subsequent analysis of the methylated mSEPT9 colorectal cancer screening marker in plasma, different blood collection tubes and blood storage conditions were investigated. The study demonstrated that methylated Septin 9 ( m SEPT9) can be consistently detected in plasma samples derived from whole blood samples collected with S-Monovette® K3E and BD Vacutainer ® K2EDTA tubes stored at 2-8 °C for a maximum of 24 h and for samples collected in S-Monovette CPDA tubes stored at 18-25 °C for up to 48 h.
Kreutziger, Janett; Lederer, Wolfgang; Schmid, Stefan; Ulmer, Hanno; Wenzel, Volker; Nijsten, Maarten W; Werner, Daniel; Schlechtriemen, Thomas
2018-01-01
Deranged glucose metabolism after moderate to severe trauma with either high or low concentrations of blood glucose is associated with poorer outcome. Data on prehospital blood glucose concentrations and trauma are scarce. The primary aim was to describe the relationship between traumatic shock and prehospital blood glucose concentrations. The secondary aim was to determine the additional predictive value of prehospital blood glucose concentration for traumatic shock when compared with vital parameters alone. Retrospective analysis of the predefined, observational database of a nationwide Helicopter Emergency Medical Service (34 bases). Emergency trauma patients treated by Helicopter Emergency Medical Service between 2005 and 2013 were investigated. All adult trauma patients (≥18 years) with recorded blood glucose concentrations were enrolled. Primary outcome: upper and lower thresholds of blood glucose concentration more commonly associated with traumatic shock. Secondary outcome: additional predictive value of prehospital blood glucose concentrations when compared with vital parameters alone. Of 51 936 trauma patients, 20 177 were included. In total, 220 (1.1%) patients died on scene. Hypoglycaemia (blood glucose concentration 2.8 mmol l or less) was observed in 132 (0.7%) patients, hyperglycaemia (blood glucose concentration exceeding 15 mmol l) was observed in 265 patients (1.3%). Blood glucose concentrations more than 10 mmol l (n = 1308 (6.5%)) and 2.8 mmol l or less were more common in patients with traumatic shock (P < 0.0001). The Youden index for traumatic shock ((sensitivity + specificity) - 1) was highest when blood glucose concentration was 3.35 mmol l (P < 0.001) for patients with low blood glucose concentrations and 7.75 mmol l (P < 0.001) for those with high blood glucose concentrations. In logistic regression analysis of patients with spontaneous circulation on scene, prehospital blood glucose concentrations (together with common vital parameters: Glasgow Coma Scale, heart rate, blood pressure, breathing frequency) significantly improved the prediction of traumatic shock in comparison with prediction by common vital parameters alone (P < 0.0001). In adult trauma patients, low and high blood glucose concentrations were more common in patients with traumatic shock. Prehospital blood glucose concentration measurements in addition to common vital parameters may help identify patients at risk of traumatic shock.
Coagulation dynamics of a blood sample by multiple scattering analysis
NASA Astrophysics Data System (ADS)
Faivre, Magalie; Peltié, Philippe; Planat-Chrétien, Anne; Cosnier, Marie-Line; Cubizolles, Myriam; Nougier, Christophe; Négrier, Claude; Pouteau, Patrick
2011-05-01
We report a new technique to measure coagulation dynamics on whole-blood samples. The method relies on the analysis of the speckle figure resulting from a whole-blood sample mixed with coagulation reagent and introduced in a thin chamber illuminated with a coherent light. A dynamic study of the speckle reveals a typical behavior due to coagulation. We compare our measured coagulation times to a reference method obtained in a medical laboratory.
[Analysis of heat transfer in the biological tissue layer with distributed system of blood vessels].
Bogatov, N M; Pelipenko, O N
2005-09-01
Processes of heat transfer in the skin layer with blood vessels were investigated using mathematical modeling. Analysis of influence of a pathological state of blood vessels on heterogeneity of thermal field of the skin surface was carried out. For each site of body surface, there is a certain difference of temperature between normal and pathological sites, being specific for differential diagnosis of diseases of dermal and hypodermic vessels.
NASA Astrophysics Data System (ADS)
Hamelin, Elizabeth I.; Blake, Thomas A.; Perez, Jonas W.; Crow, Brian S.; Shaner, Rebecca L.; Coleman, Rebecca M.; Johnson, Rudolph C.
2016-05-01
Public health response to large scale chemical emergencies presents logistical challenges for sample collection, transport, and analysis. Diagnostic methods used to identify and determine exposure to chemical warfare agents, toxins, and poisons traditionally involve blood collection by phlebotomists, cold transport of biomedical samples, and costly sample preparation techniques. Use of dried blood spots, which consist of dried blood on an FDA-approved substrate, can increase analyte stability, decrease infection hazard for those handling samples, greatly reduce the cost of shipping/storing samples by removing the need for refrigeration and cold chain transportation, and be self-prepared by potentially exposed individuals using a simple finger prick and blood spot compatible paper. Our laboratory has developed clinical assays to detect human exposures to nerve agents through the analysis of specific protein adducts and metabolites, for which a simple extraction from a dried blood spot is sufficient for removing matrix interferents and attaining sensitivities on par with traditional sampling methods. The use of dried blood spots can bridge the gap between the laboratory and the field allowing for large scale sample collection with minimal impact on hospital resources while maintaining sensitivity, specificity, traceability, and quality requirements for both clinical and forensic applications.
NASA Astrophysics Data System (ADS)
Manicke, Nicholas Edward; Abu-Rabie, Paul; Spooner, Neil; Ouyang, Zheng; Cooks, R. Graham
2011-09-01
A method is presented for the direct quantitative analysis of therapeutic drugs from dried blood spot samples by mass spectrometry. The method, paper spray mass spectrometry, generates gas phase ions directly from the blood card paper used to store dried blood samples without the need for complex sample preparation and separation; the entire time for preparation and analysis of blood samples is around 30 s. Limits of detection were investigated for a chemically diverse set of some 15 therapeutic drugs; hydrophobic and weakly basic drugs, such as sunitinib, citalopram, and verapamil, were found to be routinely detectable at approximately 1 ng/mL. Samples were prepared by addition of the drug to whole blood. Drug concentrations were measured quantitatively over several orders of magnitude, with accuracies within 10% of the expected value and relative standard deviation (RSD) of around 10% by prespotting an internal standard solution onto the paper prior to application of the blood sample. We have demonstrated that paper spray mass spectrometry can be used to quantitatively measure drug concentrations over the entire therapeutic range for a wide variety of drugs. The high quality analytical data obtained indicate that the technique may be a viable option for therapeutic drug monitoring.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Yangho; Lee, Byung-Kook, E-mail: bklee@sch.ac.kr
Introduction: The objective of this study was to evaluate associations between blood lead, cadmium, and mercury levels with estimated glomerular filtration rate in a general population of South Korean adults. Methods: This was a cross-sectional study based on data obtained in the Korean National Health and Nutrition Examination Survey (KNHANES) (2008-2010). The final analytical sample consisted of 5924 participants. Estimated glomerular filtration rate (eGFR) was calculated using the MDRD Study equation as an indicator of glomerular function. Results: In multiple linear regression analysis of log2-transformed blood lead as a continuous variable on eGFR, after adjusting for covariates including cadmium andmore » mercury, the difference in eGFR levels associated with doubling of blood lead were -2.624 mL/min per 1.73 m Superscript-Two (95% CI: -3.803 to -1.445). In multiple linear regression analysis using quartiles of blood lead as the independent variable, the difference in eGFR levels comparing participants in the highest versus the lowest quartiles of blood lead was -3.835 mL/min per 1.73 m Superscript-Two (95% CI: -5.730 to -1.939). In a multiple linear regression analysis using blood cadmium and mercury, as continuous or categorical variables, as independent variables, neither metal was a significant predictor of eGFR. Odds ratios (ORs) and 95% CI values for reduced eGFR calculated for log2-transformed blood metals and quartiles of the three metals showed similar trends after adjustment for covariates. Discussion: In this large, representative sample of South Korean adults, elevated blood lead level was consistently associated with lower eGFR levels and with the prevalence of reduced eGFR even in blood lead levels below 10 {mu}g/dL. In conclusion, elevated blood lead level was associated with lower eGFR in a Korean general population, supporting the role of lead as a risk factor for chronic kidney disease.« less
Individual patient data meta-analysis of self-monitoring of blood pressure (BP-SMART): a protocol
Tucker, Katherine L; Sheppard, James P; Stevens, Richard; Bosworth, Hayden B; Bove, Alfred; Bray, Emma P; Godwin, Marshal; Green, Beverly; Hebert, Paul; Hobbs, F D Richard; Kantola, Ilkka; Kerry, Sally; Magid, David J; Mant, Jonathan; Margolis, Karen L; McKinstry, Brian; Omboni, Stefano; Ogedegbe, Olugbenga; Parati, Gianfranco; Qamar, Nashat; Varis, Juha; Verberk, Willem; Wakefield, Bonnie J; McManus, Richard J
2015-01-01
Introduction Self-monitoring of blood pressure is effective in reducing blood pressure in hypertension. However previous meta-analyses have shown a considerable amount of heterogeneity between studies, only part of which can be accounted for by meta-regression. This may be due to differences in design, recruited populations, intervention components or results among patient subgroups. To further investigate these differences, an individual patient data (IPD) meta-analysis of self-monitoring of blood pressure will be performed. Methods and analysis We will identify randomised trials that have compared patients with hypertension who are self-monitoring blood pressure with those who are not and invite trialists to provide IPD including clinic and/or ambulatory systolic and diastolic blood pressure at baseline and all follow-up points where both intervention and control groups were measured. Other data requested will include measurement methodology, length of follow-up, cointerventions, baseline demographic (age, gender) and psychosocial factors (deprivation, quality of life), setting, intensity of self-monitoring, self-monitored blood pressure, comorbidities, lifestyle factors (weight, smoking) and presence or not of antihypertensive treatment. Data on all available patients will be included in order to take an intention-to-treat approach. A two-stage procedure for IPD meta-analysis, stratified by trial and taking into account age, sex, diabetes and baseline systolic BP will be used. Exploratory subgroup analyses will further investigate non-linear relationships between the prespecified variables. Sensitivity analyses will assess the impact of trials which have and have not provided IPD. Ethics and dissemination This study does not include identifiable data. Results will be disseminated in a peer-reviewed publication and by international conference presentations. Conclusions IPD analysis should help the understanding of which self-monitoring interventions for which patient groups are most effective in the control of blood pressure. PMID:26373404
Liu, Wenjie; Duan, Yuchen; Cui, Wenyao; Li, Li; Wang, Xia; Dai, Heling; You, Chao; Chen, Maojun
2016-07-01
To compare the efficacy of several antiseptics in decreasing the blood culture contamination rate. Network meta-analysis. Electronic searches of PubMed and Embase were conducted up to November 2015. Only randomized controlled trials or quasi-randomized controlled trials were eligible. We applied no language restriction. A comprehensive review of articles in the reference lists was also accomplished for possible relevant studies. Relevant studies evaluating efficacy of different antiseptics in venous puncture site for decreasing the blood culture contamination rate were included. The data were extracted from the included randomized controlled trials by two authors independently. The risk of bias was evaluated using Detsky scale by two authors independently. We used WinBUGS1.43 software and statistic model described by Chaimani to perform this network meta-analysis. Then graphs of statistical results of WinBUGS1.43 software were generated using 'networkplot', 'ifplot', 'netfunnel' and 'sucra' procedure by STATA13.0. Odds ratio and 95% confidence intervals were assessed for dichotomous data. A probability of p less than 0.05 was considered to be statistically significant. Compared with ordinary meta-analyses, this network meta-analysis offered hierarchies for the efficacy of different antiseptics in decreasing the blood culture contamination rate. Seven randomized controlled trials involving 34,408 blood samples were eligible for the meta-analysis. No significant difference was found in blood culture contamination rate among different antiseptics. No significant difference was found between non-alcoholic antiseptics and alcoholic antiseptics, alcoholic chlorhexidine and povidone iodine, chlorhexidine and iodine compounds, povidone iodine and iodine tincture in this aspect, respectively. Different antiseptics may not affect the blood culture contamination rate. Different intervals between the skin disinfection and the venous puncture, the different settings (emergency room, medical wards, and intensive care units) and the performance of the phlebotomy may affect the blood culture contamination rate. Copyright © 2016 Elsevier Ltd. All rights reserved.
Park, Sungjin; Moon, SeongRyeol; Lee, Kiyoung; Park, Ie Byung; Lee, Dae Ho; Nam, Seungyoon
2018-01-01
Diabetic nephropathy (DN), a major diabetic microvascular complication, has a long and growing list of biomarkers, including microRNA biomarkers, which have not been consistent across preclinical and clinical studies. This meta-analysis aims to identify significant blood- and urine-incident microRNAs as diagnostic/prognostic biomarker candidates for DN. PubMed, Web of Science, and Cochrane Library were searched from their earliest records through 12th Dec 2016. Relevant publications for the meta-analysis included (1) human participants; (2) microRNAs in blood and urine; (3) DN studies; and (4) English language. Four reviewers, including two physicians, independently and blindly extracted published data regarding microRNA profiles in blood and/or urine from subjects with diabetic nephropathy. A random-effect model was used to pool the data. Statistical associations between diabetic nephropathy and urinary or blood microRNA expression levels were assessed. Fourteen out of 327 studies (n=2,747 patients) were selected. Blood or urinary microRNA expression data of diabetic nephropathy were pooled for this analysis. The hsa-miR-126 family was significantly (OR: 0.57; 95% CI: 0.44-0.74; p-value < 0.0001) downregulated in blood from patients with diabetic kidney disease, while its urinary level was upregulated (OR: 2931.12; 95% CI: 9.96-862623.21; p-value = 0.0059). The hsa-miR-770 family microRNA were significantly (OR: 10.24; 95% CI: 2.37-44.25; p-value = 0.0018) upregulated in both blood and urine from patients with diabetic nephropathy. Our meta-analysis suggests that hsa-miR-126 and hsa-miR-770 family microRNA may have important diagnostic and pathogenetic implications for DN, which warrants further systematic clinical studies. © 2018 The Author(s). Published by S. Karger AG, Basel.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bornschein, R.L.; Succop, P.; Dietrich, K.N.
The roles of environmental and behavioral factors in determining blood lead levels were studied in a cohort of young children living in an urban environment. The subjects were observed at 3-month intervals from birth to 24 months of age. Repeated measurements were made of the children's blood lead levels, environmental levels of lead in house dust, and in the dust found on the children's hands. A qualitative rating of the residence and of the socioeconomic status of the family was obtained. Interviews and direct observation of parent and child at home were used to evaluate various aspects of caretaker-child interactions.more » Data analysis consisted of a comparison of results obtained by (a) simple correlational analysis, (b) multiple regression analysis, and (c) structural equations analysis. The results demonstrated that structural equation modeling offers a useful approach to unraveling the complex interactions present in the data set. In this preliminary analysis, the suspected relationship between the levels of lead in house dust and on hands and the blood lead level was clearly demonstrated. Furthermore, the analyses indicated an important interplay between environmental sources and social factors in the determination of hand lead and blood lead levels in very young children.« less
Detection of Leukemia with Blood Samples Using Raman Spectroscopy and Multivariate Analysis
NASA Astrophysics Data System (ADS)
Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.
2009-06-01
The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. Blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteers. The imprint was put under the microscope and several points were chosen for Raman measurement. All the spectra were collected by a confocal Raman micro-spectroscopy (Renishaw) with a NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) are applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. The preliminary results suggest that Raman Spectroscopy could be a new technique to study the degree of damage to the bone marrow using just blood samples instead of biopsies, treatment very painful for patients.
Verplaetse, Ruth; Henion, Jack
2016-01-01
Opioids are well known, widely used painkillers. Increased stability of opioids in the dried blood spot (DBS) matrix compared to blood/plasma has been described. Other benefits provided by DBS techniques include point-of-care collection, less invasive micro sampling, more economical shipment, and convenient storage. Current methodology for analysis of micro whole blood samples for opioids is limited to the classical DBS workflow, including tedious manual punching of the DBS cards followed by extraction and liquid chromatography-tandem mass spectrometry (LC-MS/MS) bioanalysis. The goal of this study was to develop and validate a fully automated on-line sample preparation procedure for the analysis of DBS micro samples relevant to the detection of opioids in finger prick blood. To this end, automated flow-through elution of DBS cards was followed by on-line solid-phase extraction (SPE) and analysis by LC-MS/MS. Selective, sensitive, accurate, and reproducible quantitation of five representative opioids in human blood at sub-therapeutic, therapeutic, and toxic levels was achieved. The range of reliable response (R(2) ≥0.997) was 1 to 500 ng/mL whole blood for morphine, codeine, oxycodone, hydrocodone; and 0.1 to 50 ng/mL for fentanyl. Inter-day, intra-day, and matrix inter-lot accuracy and precision was less than 15% (even at lower limits of quantitation (LLOQ) level). The method was successfully used to measure hydrocodone and its major metabolite norhydrocodone in incurred human samples. Our data support the enormous potential of DBS sampling and automated analysis for monitoring opioids as well as other pharmaceuticals in both anti-doping and pain management regimens. Copyright © 2015 John Wiley & Sons, Ltd.
Mi, Bobin; Liu, Guohui; Zhou, Wu; Lv, Huijuan; Liu, Yi; Zha, Kun; Wu, Qipeng; Liu, Jing
2017-07-01
The purpose of this meta-analysis was to compare the blood loss and complications of intra-articular (IA) with intravenous (IV) tranexamic acid (TXA) for total knee arthroplasty (TKA). A comprehensive search of studies was conducted to identify related articles in Pubmed, Embase, Cochrane central Register of Controlled Trials, springerLink, OVID and the Research published from January 1980 to September 2016. All studies that compared IA TXA with IV TXA application on TKA were included. Main outcomes of the two methods were collected and analyzed by using Review Manager 5.3. There were 16 randomized controlled trials with 1308 cases met the criteria. Compared with IV TXA, IA TXA had similar blood volume of drainage, hidden blood loss, transfusion rate and complications (P > 0.05). IA TXA had lower total blood loss than IV TXA, and there was significant difference (P < 0.05). Subgroup analysis of total blood loss based on times of IV TXA administration showed that repeat dose of IV TXA had a higher total blood loss and postoperative hemoglobin drop (P < 0.05) than IA TXA. However, single dose of IV TXA had a similar efficacy on total blood loss and postoperative hemoglobin drop (P > 0.05) when compared with IA TXA. Both IA TXA and single dose of IV TXA are effective in reducing total blood loss and postoperative hemoglobin drop without increasing complications of DVT or PE. The current meta-analysis suggests that 1.5 g TXA by IA administration or 1 g TXA by IV administration 10 min before tourniquet deflation is effective and safe in patients undergoing TKA.
Quantitative interpretations of Visible-NIR reflectance spectra of blood.
Serebrennikova, Yulia M; Smith, Jennifer M; Huffman, Debra E; Leparc, German F; García-Rubio, Luis H
2008-10-27
This paper illustrates the implementation of a new theoretical model for rapid quantitative analysis of the Vis-NIR diffuse reflectance spectra of blood cultures. This new model is based on the photon diffusion theory and Mie scattering theory that have been formulated to account for multiple scattering populations and absorptive components. This study stresses the significance of the thorough solution of the scattering and absorption problem in order to accurately resolve for optically relevant parameters of blood culture components. With advantages of being calibration-free and computationally fast, the new model has two basic requirements. First, wavelength-dependent refractive indices of the basic chemical constituents of blood culture components are needed. Second, multi-wavelength measurements or at least the measurements of characteristic wavelengths equal to the degrees of freedom, i.e. number of optically relevant parameters, of blood culture system are required. The blood culture analysis model was tested with a large number of diffuse reflectance spectra of blood culture samples characterized by an extensive range of the relevant parameters.
Increased monocytes and bands following a red blood cell transfusion.
Ellefson, A M; Locke, R G; Zhao, Y; Mackley, A B; Paul, D A
2016-01-01
The objective of this study is to analyze the white blood cell changes that occur after a transfusion of red blood cells in order to identify a subclinical inflammatory response in neonates. Retrospective analysis of infants who received a red blood cell transfusion in an intensive care nursery. White blood cell results within 24 h pre- to 48 h post-transfusion were collected and analyzed. Statistical analysis included ANOVA, T-test, Mann-Whitney U test, Pearson's correlation and multivariable linear regression. Monocytes (P=0.02) and bands (P=0.035) were increased post-transfusion. There were no differences in monocytes (P=0.46) or bands (P=0.56) between groups who did or did not have blood cultures obtained. There was no difference in monocytes between groups who did or did not have sepsis (P=0.88). We identified an elevation in monocytes and bands in the 48 h following a transfusion in premature infants. Our findings support a possible pro-inflammatory response related to transfusion of red blood cells.
NASA Astrophysics Data System (ADS)
Martin, Nicholas J.; Bunch, Josephine; Cooper, Helen J.
2013-08-01
Dried blood spots offer many advantages as a sample format including ease and safety of transport and handling. To date, the majority of mass spectrometry analyses of dried blood spots have focused on small molecules or hemoglobin. However, dried blood spots are a potentially rich source of protein biomarkers, an area that has been overlooked. To address this issue, we have applied an untargeted bottom-up proteomics approach to the analysis of dried blood spots. We present an automated and integrated method for extraction of endogenous proteins from the surface of dried blood spots and sample preparation via trypsin digestion by use of the Advion Biosciences Triversa Nanomate robotic platform. Liquid chromatography tandem mass spectrometry of the resulting digests enabled identification of 120 proteins from a single dried blood spot. The proteins identified cross a concentration range of four orders of magnitude. The method is evaluated and the results discussed in terms of the proteins identified and their potential use as biomarkers in screening programs.
Stock, W; Westbrook, C A; Peterson, B; Arthur, D C; Szatrowski, T P; Silver, R T; Sher, D A; Wu, D; Le Beau, M M; Schiffer, C A; Bloomfield, C D
1997-01-01
Disappearance of the Philadelphia chromosome during treatment for chronic myeloid leukemia (CML) has become an important therapeutic end point. To determine the additional value of molecular monitoring during treatment for CML, we performed a prospective, sequential analysis using quantitative Southern blot monitoring of BCR gene rearrangements of blood and marrow samples from Cancer and Leukemia Group B (CALGB) study 8761. Sixty-four previously untreated adults with chronic-phase CML who were enrolled onto CALGB 8761, a molecular-monitoring companion study to a treatment study for adults with chronic-phase CML (CALGB 9013). Treatment consisted of repetitive cycles of interferon alfa and low-dose subcutaneous cytarabine. Blood and marrow Southern blot quantitation of BCR gene rearrangements was compared with marrow cytogenetic analysis before the initiation of treatment and of specified points during therapy. Reverse-transcriptase polymerase chain reaction (RT-PCR) analysis was performed to detect residual disease in patients who achieved a complete response by Southern blot or cytogenetic analysis. Quantitative molecular monitoring by Southern blot analysis of blood samples was found to be equivalent to marrow monitoring at all time points. Twelve of 62 (19%) follow-up samples studied by Southern blot analysis had a complete loss of BCR gene rearrangement in matched marrow and blood specimens. Southern blot monitoring of blood samples was also found to be highly correlated to marrow cytogenetic evaluation at all points, although there were four discordant cases in which Southern blot analysis of blood showed no BCR gene rearrangement, yet demonstrated from 12% to 20% Philadelphia chromosome-positive metaphase cells in the marrow. RT-PCR analysis detected residual disease in five of six patients in whom no malignant cells were detected using Southern blot or cytogenetic analyses. Quantitative Southern blot analysis of blood samples may be substituted for bone marrow to monitor the response to therapy in CML and results in the need for fewer bone marrow examinations. To avoid overestimating the degree of response, marrow cytogenetic analysis should be performed when patients achieve a complete response by Southern blot monitoring. This approach provides a rational, cost-effective strategy to monitor the effect of treatment of individual patients, as well as to analyze large clinical trials in CML.
Shibata, Masanori; Nagai, Kojiro; Doi, Toshio; Tawada, Hideo; Taniguchi, Shinkichi
2012-11-01
Blood color of dialysis patients can be seen routinely. Darkened blood color is often observed in critically ill patients generally because of decreased oxygen saturation, but little is known about the other factors responsible for the color intensity. In addition, quantitative blood color examination has not been performed yet. Therefore, no one has evaluated the predictive power of blood color. The aim of this study was to evaluate if blood color darkness reflects some medical problems and is associated with survival disadvantage. Study design is a prospective cohort study. One hundred sixty-seven patients were enrolled in this study. Quantification of blood color was done using a reflected light colorimeter. Demographic and clinical data were collected to find out the factors that can be related to blood color. Follow-ups were performed for 2 years to analyze the risk factors for their survival. Regression analysis showed that C-reactive protein and white blood cell count were negatively correlated with blood color. In addition, blood color was positively correlated with mean corpuscular hemoglobin concentration and serum sodium concentration as well as blood oxygen saturation. During a follow-up, 34 (20.4%) patients died. Cox regression analysis revealed that darkened blood color was an independent significant risk factor of mortality in hemodialysis patients as well as low albumin and low Kt/V. These results suggest that inflammation independently affects blood color and quantification of blood color is useful to estimate prognosis in patients undergoing hemodialysis. It is possible that early detection of blood color worsening can improve patients' survival. © 2012, Copyright the Authors. Artificial Organs © 2012, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Yuan, Qiu-Ming; Zhao, Zhi-Hu; Xu, Bao-Shan
2017-01-01
The purpose of this systematic review and meta-analysis of randomized controlled trials (RCTs) and non-RCTs was to gather data to evaluate the efficacy and safety of tranexamic acid (TXA) versus placebo after a scoliosis surgery. The electronic databases including Embase, PubMed, CENTRAL (Cochrane Controlled Trials Register), Web of Science, and Google database were searched to identify relevant studies published from the time of the establishment of these databases up to May 2016. This systematic review and meta-analysis was performed according to the PRISMA statement criteria. The primary outcomes were total blood loss, intraoperative blood loss, and hemoglobin after surgery. The second outcome is need for transfusion. Stata 12.0 software was used for the meta-analysis. After testing for publication bias and heterogeneity across studies, data were aggregated for random-effects modeling when necessary. A total of 685 patients (347 patients in the TXA group and 338 in the control group) were finally included for this meta-analysis. The pooled results revealed that administration of TXA can decrease the total blood loss after scoliosis surgery [mean difference (MD) = 682.30, 95% confidence interval (CI) -930.60 to -434.00; P = 0.000] and intraoperative blood loss [(MD) = -535.28; 95% CI -683.74 to -368.82; P = 0.000]. For the hemoglobin (Hb) value after scoliosis surgery, TXA can decrease the Hb value for 0.51 dL [(MD) = 0.51; 95% CI 0.25-0.78; P = 0.000]. There is no statistically significant difference between the TXA versus placebo in terms of the need for transfusion (relative risk = 0.55, 95% CI 0.25-1.20, P = 0.132). Based on the current meta-analysis, TXA can decrease the total blood loss and intraoperative blood loss during scoliosis surgery. It is recommended that it be routinely used in scoliosis surgery. High-dose TXA (>20 mg/kg) is more effective than low-dose TXA (<20 mg/kg) in controlling blood loss. However, for the need for transfusion, more high-quality RCTs need to be identified.
Dukić, Lora; Simundić, Ana-Maria
2014-01-01
The aim of this survey study was to assess the current practices and policies in use related to the various steps in the blood gas testing process, across hospital laboratories in Croatia. First questionnaire was sent by email to all medical biochemistry laboratories (N = 104) within general, specialized and clinical hospitals and university hospital centres to identify laboratories which perform blood gas analysis. Second questionnaire with detailed questions about sample collection, analysis and quality control procedures, was sent only to 47 laboratories identified by the first survey. Questionnaire was designed as combination of questions and statements with Likert scale. Third questionnaire was sent to all participating laboratories (N=47) for additional clarification for either indeterminate or unclear answers. Blood gas analysis is performed in 47/104 hospital laboratories in Croatia. In 25/41 (0.61) of the laboratories capillary blood gas sampling is the preferred sample type for adult patient population, whereas arterial blood sample is preferentially used in only 5/44 laboratories (0.11). Blood sampling and sample processing for capillary samples is done almost always by laboratory technicians (36/41 and 37/44, respectively), whereas arterial blood sampling is almost always done by the physician (24/29) and only rarely by a nurse (5/28). Sample acceptance criteria and sample analysis are in accordance with international recommendations for majority of laboratories. 43/44 laboratories participate in the national EQA program. POCT analyzers are installed outside of the laboratory in 20/47 (0.43) institutions. Laboratory staff is responsible for education and training of ward personnel, quality control and instrument maintenance in only 12/22, 11/20 and 9/20 institutions, respectively. Practices related to collection and analysis for blood gases in Croatia are not standardised and vary substantially between laboratories. POCT analyzers are not under the direct supervision by laboratory personnel in a large proportion of surveyed institutions. Collective efforts should be made to harmonize and improve policies and procedures related to blood gas testing in Croatian laboratories.
Nikolian, Vahagn C; Dekker, Simone E; Bambakidis, Ted; Higgins, Gerald A; Dennahy, Isabel S; Georgoff, Patrick E; Williams, Aaron M; Andjelkovic, Anuska V; Alam, Hasan B
2018-01-01
Combined traumatic brain injury and hemorrhagic shock are highly lethal. Following injuries, the integrity of the blood-brain barrier can be impaired, contributing to secondary brain insults. The status of the blood-brain barrier represents a potential factor impacting long-term neurologic outcomes in combined injuries. Treatment strategies involving plasma-based resuscitation and valproic acid therapy have shown efficacy in this setting. We hypothesize that a component of this beneficial effect is related to blood-brain barrier preservation. Following controlled traumatic brain injury, hemorrhagic shock, various resuscitation and treatment strategies were evaluated for their association with blood-brain barrier integrity. Analysis of gene expression profiles was performed using Porcine Gene ST 1.1 microarray. Pathway analysis was completed using network analysis tools (Gene Ontology, Ingenuity Pathway Analysis, and Parametric Gene Set Enrichment Analysis). Female Yorkshire swine were subjected to controlled traumatic brain injury and 2 hours of hemorrhagic shock (40% blood volume, mean arterial pressure 30-35 mmHg). Subjects were resuscitated with 1) normal saline, 2) fresh frozen plasma, 3) hetastarch, 4) fresh frozen plasma + valproic acid, or 5) hetastarch + valproic acid (n = 5 per group). After 6 hours of observation, brains were harvested for evaluation. Immunofluoroscopic evaluation of the traumatic brain injury site revealed significantly increased expression of tight-junction associated proteins (zona occludin-1, claudin-5) following combination therapy (fresh frozen plasma + valproic acid and hetastarch + valproic acid). The extracellular matrix protein laminin was found to have significantly improved expression with combination therapies. Pathway analysis indicated that valproic acid significantly modulated pathways involved in endothelial barrier function and cell signaling. Resuscitation with fresh frozen plasma results in improved expression of proteins essential for blood-brain barrier integrity. The addition of valproic acid provides significant improvement to these protein expression profiles. This is likely secondary to activation of key pathways related to endothelial functions.
Schecter, Arnold; Colacino, Justin A; Shah, Nirav; Harris, T Robert; Papke, Olaf
2009-01-01
For analysis of organochlorine contaminants in human tissue, the "gold standard" for preservation, storage, and shipping is usually freezing. However, this method can be difficult, if samples are taken in remote areas, and costly, when the samples must be shipped on dry ice. Therefore, a more simple and cost effective method of preservation is essential for remote field work. Potassium dichromate (K(2)Cr(2)O(7)) has been successfully employed in the preservation of human and cows' milk as well as chicken eggs. Our previous studies described the use of potassium dichromate for preservation of whole blood for analysis of dioxins, dibenzofurans, and PCBs. Potassium dichromate was found to successfully preserve blood at room temperature for 34 d with no significant differences in the measured concentrations of chemical contaminants or blood lipid level when compared to frozen samples. However, in a follow-up study, 3 months and 6 months of potassium dichromate preservation proved inadequate to preserve the samples for organic pollutant analysis. We noted that the lipid portion of the blood in the chemically preserved samples was declining in level or degrading, while the persistent organic pollutants remained intact at the same levels on a whole weight basis. To narrow down the window of efficacy for the use of potassium dichromate to preserve blood samples for analysis, the present study compared chemical preservation to freezing for an intermediate time period, 2 months. Similar to our previous findings at 3 and 6 months, at 2 months significant lipid degradation was observed in the chemically preserved samples. Chemically preserved samples had significantly higher levels of organochlorine contaminants (dioxins, dibenzofurans, and PCBs) when measured on a blood lipid basis but not on a wet weight basis compared to frozen samples. While 2 months of potassium dichromate preservation was not useful for obtaining accurate measure of dioxins, furans, and PCBs on a lipid basis, previous studies found this method of preservation to be useful for at least one month (Schecter, A., Pavuk, M., Päpke, O., Malisch, R., 2004. The use of potassium dichromate and ethyl alcohol as blood preservatives for analysis of organochlorine contaminants. Chemosphere 57, 1-7). However blood stored at -70 degrees C and at 22 degrees C with potassium dichromate gave similar results when expressed on a wet weight basis.
Rapid evaluation of fibrinogen levels using the CG02N whole blood coagulation analyzer.
Hayakawa, Mineji; Gando, Satoshi; Ono, Yuichi; Mizugaki, Asumi; Katabami, Kenichi; Maekawa, Kunihiko; Miyamoto, Daisuke; Wada, Takeshi; Yanagida, Yuichiro; Sawamura, Atsushi
2015-04-01
Rapid evaluation of fibrinogen (Fbg) levels is essential for maintaining homeostasis in patients with massive bleeding during severe trauma and major surgery. This study evaluated the accuracy of fibrinogen levels measured by the CG02N whole blood coagulation analyzer (A&T Corporation, Kanagawa, Japan) using heparinized blood drawn for blood gas analysis (whole blood-Fbg). A total of 100 matched pairs of heparinized blood samples and citrated blood samples were simultaneously collected from patients in the intensive care unit. Whole blood-Fbg results were compared with those of citrated plasma (standard-Fbg). The whole blood coagulation analyzer measured fibrinogen levels within 2 minutes. Strong correlations between standard-Fbg and whole blood-Fbg were observed (ρ = 0.91, p < 0.001). Error grid analysis showed that 88% of the values were clinically acceptable, and 12% were in a range with possible effects on clinical decision-making; none were in a clinically dangerous range without appropriate treatment. Using a fibrinogen cutoff value of 1.5 g/L for standard-Fbg, the area under the receiver operating characteristic curve of whole blood-Fbg was 0.980 (95% confidence interval 0.951-1.000, p < 0.001). The whole blood coagulation analyzer can rapidly measure fibrinogen levels in heparinized blood and could be useful in critical care settings where excessive bleeding is a concern. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.
Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil
2016-11-01
Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Van Elswyk, Mary; Alexander, Dominik D.
2014-01-01
BACKGROUND Although a large body of literature has been devoted to examining the relationship between eicosapentaenoic and docosahexaenoic acids (EPA+DHA) and blood pressure, past systematic reviews have been hampered by narrow inclusion criteria and a limited scope of analytical subgroups. In addition, no meta-analysis to date has captured the substantial volume of randomized controlled trials (RCTs) published in the past 2 years. The objective of this meta-analysis was to examine the effect of EPA+DHA, without upper dose limits and including food sources, on blood pressure in RCTs. METHODS Random-effects meta-analyses were used to generate weighted group mean differences and 95% confidence intervals (CIs) between the EPA+DHA group and the placebo group. Analyses were conducted for subgroups defined by key subject or study characteristics. RESULTS Seventy RCTs were included. Compared with placebo, EPA+DHA provision reduced systolic blood pressure (−1.52mm Hg; 95% confidence interval (CI) = −2.25 to −0.79) and diastolic blood pressure (−0.99mm Hg; 95% CI = −1.54 to −0.44) in the meta-analyses of all studies combined. The strongest effects of EPA+DHA were observed among untreated hypertensive subjects (systolic blood pressure = −4.51mm Hg, 95% CI = −6.12 to −2.83; diastolic blood pressure = −3.05mm Hg, 95% CI = −4.35 to −1.74), although blood pressure also was lowered among normotensive subjects (systolic blood pressure = −1.25mm Hg, 95% CI = −2.05 to −0.46; diastolic blood pressure = −0.62mm Hg, 95% CI = −1.22 to −0.02). CONCLUSIONS Overall, available evidence from RCTs indicates that provision of EPA+DHA reduces systolic blood pressure, while provision of ≥2 grams reduces diastolic blood pressure. PMID:24610882
Miller, Paige E; Van Elswyk, Mary; Alexander, Dominik D
2014-07-01
Although a large body of literature has been devoted to examining the relationship between eicosapentaenoic and docosahexaenoic acids (EPA+DHA) and blood pressure, past systematic reviews have been hampered by narrow inclusion criteria and a limited scope of analytical subgroups. In addition, no meta-analysis to date has captured the substantial volume of randomized controlled trials (RCTs) published in the past 2 years. The objective of this meta-analysis was to examine the effect of EPA+DHA, without upper dose limits and including food sources, on blood pressure in RCTs. Random-effects meta-analyses were used to generate weighted group mean differences and 95% confidence intervals (CIs) between the EPA+DHA group and the placebo group. Analyses were conducted for subgroups defined by key subject or study characteristics. Seventy RCTs were included. Compared with placebo, EPA+DHA provision reduced systolic blood pressure (-1.52 mm Hg; 95% confidence interval (CI) = -2.25 to -0.79) and diastolic blood pressure (-0.99 mm Hg; 95% CI = -1.54 to -0.44) in the meta-analyses of all studies combined. The strongest effects of EPA+DHA were observed among untreated hypertensive subjects (systolic blood pressure = -4.51 mm Hg, 95% CI = -6.12 to -2.83; diastolic blood pressure = -3.05 mm Hg, 95% CI = -4.35 to - 1.74), although blood pressure also was lowered among normotensive subjects (systolic blood pressure = -1.25 mm Hg, 95% CI = -2.05 to -0.46; diastolic blood pressure = -0.62 mm Hg, 95% CI = -1.22 to -0.02). Overall, available evidence from RCTs indicates that provision of EPA+DHA reduces systolic blood pressure, while provision of ≥2 grams reduces diastolic blood pressure. © The Author 2014. Published by Oxford University Press on behalf of the American Journal of Hypertension.
Association of betaine with blood pressure in dialysis patients.
Wang, Lulu; Zhao, Mingming; Liu, Wenjin; Li, Xiurong; Chu, Hong; Bai, Youwei; Sun, Zhuxing; Gao, Chaoqing; Zheng, Lemin; Yang, Junwei
2018-02-01
Mechanisms underlying elevated blood pressure in dialysis patients are complex as a variety of non-traditional factors are involved. We sought to explore the association of circulating betaine, a compound widely distributed in food, with blood pressure in dialysis patients. We used baseline data of an ongoing cohort study involving patients on hemodialysis. Plasma betaine was measured by high performance liquid chromatography in 327 subjects. Blood pressure level was determined by intradialytic ambulatory blood pressure monitoring. The mean age of the patients was 52.6 ± 11.9 years, and 58.4% were male. Average interdialytic ambulatory systolic and diastolic blood pressure were 138.4 ± 22.7 mm Hg and 84.4 ± 12.5 mm Hg, respectively. Mean plasma betaine level was 37.6 μmol/L. Multiple linear regression analysis revealed significant associations of betaine with both systolic blood pressure (β = -3.66, P = .003) and diastolic blood pressure (β = -2.00, P = .004). The associations persisted even after extensive adjustment for cardiovascular covariates. Subgroup analysis revealed that the association between betaine and blood pressure was mainly limited to female patients. Our data suggest that alteration of circulating betaine possibly contributes to blood pressure regulation in these patients. ©2018 Wiley Periodicals, Inc.
Can gingival crevicular blood be relied upon for assessment of blood glucose level?
Dwivedi, Shivani; Verma, Sharmila J; Shah, Monali; Jain, Kapil
2014-11-01
Diabetes mellitus (DM) is undiagnosed in approximately half of the patients actually suffering from the disease. In addition, the prevalence of DM is more than twice as high as in patients with periodontitis when compared to periodontally healthy subjects. Thus, a high number of patients with periodontitis may have undiagnosed DM. The purpose of the present study was to evaluate whether blood oozing from a gingival crevice during routine periodontal examination can be used for determining glucose levels. Observational cross-sectional studies were carried out in 75 patients (43 males and 32 females) with chronic periodontitis who were divided into two groups: Group I and Group II, respectively. Blood oozing from the gingival crevices of anterior teeth following periodontal probing was collected with the stick of glucose self-monitoring device, and the blood glucose levels were measured. At the same time, finger-prick blood was taken for glucometric analysis and subsequent readings were recorded. The patient's blood glucose values ranged from 74 to 256 mg/dl. The comparison between gingival crevicular blood and finger-prick blood showed a very strong correlation, with a t value of 3.97 (at P value = 0.001). The data from this study has shown that GCB collected during diagnostic periodontal examination can be an excellent source of blood for glucometric analysis.
Effects of exposure to malathion on blood glucose concentration: a meta-analysis.
Ramirez-Vargas, Marco Antonio; Flores-Alfaro, Eugenia; Uriostegui-Acosta, Mayrut; Alvarez-Fitz, Patricia; Parra-Rojas, Isela; Moreno-Godinez, Ma Elena
2018-02-01
Exposure to malathion (an organophosphate pesticide widely used around the world) has been associated with alterations in blood glucose concentration in animal models. However, the results are inconsistent. The aim of this meta-analysis was to evaluate whether malathion exposure can disturb the concentrations of blood glucose in exposed rats. We performed a literature search of online databases including PubMed, EBSCO, and Google Scholar and reviewed original articles that analyzed the relation between malathion exposure and glucose levels in animal models. The selection of articles was based on inclusion and exclusion criteria. The database search identified thirty-five possible articles, but only eight fulfilled our inclusion criteria, and these studies were included in the meta-analysis. The effect of malathion on blood glucose concentration showed a non-monotonic dose-response curve. In addition, pooled analysis showed that blood glucose concentrations were 3.3-fold higher in exposed rats than in the control group (95% CI, 2-5; Z = 3.9; p < 0.0001) in a random-effect model. This result suggested that alteration of glucose homeostasis is a possible mechanism of toxicity associated with exposure to malathion.
[Improving blood safety: errors management in transfusion medicine].
Bujandrić, Nevenka; Grujić, Jasmina; Krga-Milanović, Mirjana
2014-01-01
The concept of blood safety includes the entire transfusion chain starting with the collection of blood from the blood donor, and ending with blood transfusion to the patient. The concept involves quality management system as the systematic monitoring of adverse reactions and incidents regarding the blood donor or patient. Monitoring of near-miss errors show the critical points in the working process and increase transfusion safety. The aim of the study was to present the analysis results of adverse and unexpected events in transfusion practice with a potential risk to the health of blood donors and patients. One-year retrospective study was based on the collection, analysis and interpretation of written reports on medical errors in the Blood Transfusion Institute of Vojvodina. Errors were distributed according to the type, frequency and part of the working process where they occurred. Possible causes and corrective actions were described for each error. The study showed that there were not errors with potential health consequences for the blood donor/patient. Errors with potentially damaging consequences for patients were detected throughout the entire transfusion chain. Most of the errors were identified in the preanalytical phase. The human factor was responsible for the largest number of errors. Error reporting system has an important role in the error management and the reduction of transfusion-related risk of adverse events and incidents. The ongoing analysis reveals the strengths and weaknesses of the entire process and indicates the necessary changes. Errors in transfusion medicine can be avoided in a large percentage and prevention is cost-effective, systematic and applicable.
Kearney, Sinéad M.; Kilcawley, Niamh A.; Early, Philip L.; Glynn, Macdara T.; Ducrée, Jens
2016-01-01
Here we present retrieval of Peripheral Blood Mononuclear Cells by density-gradient medium based centrifugation for subsequent analysis of the leukocytes on an integrated microfluidic “Lab-on-a-Disc” cartridge. Isolation of white blood cells constitutes a critical sample preparation step for many bioassays. Centrifugo-pneumatic siphon valves are particularly suited for blood processing as they function without need of surface treatment and are ‘low-pass’, i.e., holding at high centrifugation speeds and opening upon reduction of the spin rate. Both ‘hydrostatically’ and ‘hydrodynamically’ triggered centrifugo-pneumatic siphon valving schemes are presented. Firstly, the geometry of the pneumatic chamber of hydrostatically primed centrifugo-pneumatic siphon valves is optimised to enable smooth and uniform layering of blood on top of the density-gradient medium; this feature proves to be key for efficient Peripheral Blood Mononuclear Cell extraction. A theoretical analysis of hydrostatically primed valves is also presented which determines the optimum priming pressure for the individual valves. Next, ‘dual siphon’ configurations for both hydrostatically and hydrodynamically primed centrifugo-pneumatic siphon valves are introduced; here plasma and Peripheral Blood Mononuclear Cells are extracted through a distinct siphon valve. This work represents a first step towards enabling on disc multi-parameter analysis. Finally, the efficiency of Peripheral Blood Mononuclear Cells extraction in these structures is characterised using a simplified design. A microfluidic mechanism, which we termed phase switching, is identified which affects the efficiency of Peripheral Blood Mononuclear Cell extraction. PMID:27167376
2014-01-01
Background Clinically useful biomarkers for patient stratification and monitoring of disease progression and drug response are in big demand in drug development and for addressing potential safety concerns. Many diseases influence the frequency and phenotype of cells found in the peripheral blood and the transcriptome of blood cells. Changes in cell type composition influence whole blood gene expression analysis results and thus the discovery of true transcript level changes remains a challenge. We propose a robust and reproducible procedure, which includes whole transcriptome gene expression profiling of major subsets of immune cell cells directly sorted from whole blood. Methods Target cells were enriched using magnetic microbeads and an autoMACS® Pro Separator (Miltenyi Biotec). Flow cytometric analysis for purity was performed before and after magnetic cell sorting. Total RNA was hybridized on HGU133 Plus 2.0 expression microarrays (Affymetrix, USA). CEL files signal intensity values were condensed using RMA and a custom CDF file (EntrezGene-based). Results Positive selection by use of MACS® Technology coupled to transcriptomics was assessed for eight different peripheral blood cell types, CD14+ monocytes, CD3+, CD4+, or CD8+ T cells, CD15+ granulocytes, CD19+ B cells, CD56+ NK cells, and CD45+ pan leukocytes. RNA quality from enriched cells was above a RIN of eight. GeneChip analysis confirmed cell type specific transcriptome profiles. Storing whole blood collected in an EDTA Vacutainer® tube at 4°C followed by MACS does not activate sorted cells. Gene expression analysis supports cell enrichment measurements by MACS. Conclusions The proposed workflow generates reproducible cell-type specific transcriptome data which can be translated to clinical settings and used to identify clinically relevant gene expression biomarkers from whole blood samples. This procedure enables the integration of transcriptomics of relevant immune cell subsets sorted directly from whole blood in clinical trial protocols. PMID:25984272
[Clinical picture, diagnostics and prophylaxis of a syndrome in conditions of the Far North].
Ukhocskiĭ, D M; Tegza, V Iu; Rezvantsev, M V; Vasil'chenko, V V; Belikova, T M
2014-10-01
The analysis of a clinical picture barometeosensitivity in a seaside zone of the Far North is carried out in the article. A diagnostic test included the following laboratory assessments: complete blood count, complete urinary analysis, biomedical measurement assessment, immunology blood research and functional renal test; analysis of the level of an electrolyte in the blood and hormone receptor status; and the following instrumental diagnostics: The auscultatory Korotkov's method of determining blood pressure, electrocardiography, variational pulsometry, chest X-ray, mechanocardiography, echocardiography and abdominal ultrasound; and also consultation of ophthalmologist and neuropathologist. Every patient should keep a diary "weather - health" before and after the treatment. Peculiarities of cardiovascular system, vegetative systems and neuroendocrine system of servicemen, coming to the Far North and mechanisms of development of barometeosensivity were revealed. It has been established that atmospheric pressure variation affects systolic and diastolic blood pressure, heart rate, systolic discharge, Kerdo index, effectiveness of myocardial function, end-diastolic and end-systolic volume, level of cholesterol, triglycerides, kalium, adrenalin, triiodothyronine, blood plasma and plasma renin activity in barometeosensetiv servicemen. The criteria of diagnostics of barometeosensivity in conditions of the Far North are suggested. The influence of baromemteosensivity on the combat capability of serviceman is researched.
Opto-fluidics based microscopy and flow cytometry on a cell phone for blood analysis.
Zhu, Hongying; Ozcan, Aydogan
2015-01-01
Blood analysis is one of the most important clinical tests for medical diagnosis. Flow cytometry and optical microscopy are widely used techniques to perform blood analysis and therefore cost-effective translation of these technologies to resource limited settings is critical for various global health as well as telemedicine applications. In this chapter, we review our recent progress on the integration of imaging flow cytometry and fluorescent microscopy on a cell phone using compact, light-weight and cost-effective opto-fluidic attachments integrated onto the camera module of a smartphone. In our cell-phone based opto-fluidic imaging cytometry design, fluorescently labeled cells are delivered into the imaging area using a disposable micro-fluidic chip that is positioned above the existing camera unit of the cell phone. Battery powered light-emitting diodes (LEDs) are butt-coupled to the sides of this micro-fluidic chip without any lenses, which effectively acts as a multimode slab waveguide, where the excitation light is guided to excite the fluorescent targets within the micro-fluidic chip. Since the excitation light propagates perpendicular to the detection path, an inexpensive plastic absorption filter is able to reject most of the scattered light and create a decent dark-field background for fluorescent imaging. With this excitation geometry, the cell-phone camera can record fluorescent movies of the particles/cells as they are flowing through the microchannel. The digital frames of these fluorescent movies are then rapidly processed to quantify the count and the density of the labeled particles/cells within the solution under test. With a similar opto-fluidic design, we have recently demonstrated imaging and automated counting of stationary blood cells (e.g., labeled white blood cells or unlabeled red blood cells) loaded within a disposable cell counting chamber. We tested the performance of this cell-phone based imaging cytometry and blood analysis platform by measuring the density of red and white blood cells as well as hemoglobin concentration in human blood samples, which showed a good match to our measurement results obtained using a commercially available hematology analyzer. Such a cell-phone enabled opto-fluidics microscopy, flow cytometry, and blood analysis platform could be especially useful for various telemedicine applications in remote and resource-limited settings.
Collection, Storage, and Preparation of Human Blood Cells
Dagur, Pradeep K.; McCoy, J. Philip
2015-01-01
Human peripheral blood is often studied by flow cytometry in both the research and clinical laboratories. The methods for collection, storage, and preparation of peripheral blood will vary depending on the cell lineage to be examined as well as the type of assay to be performed. This unit presents protocols for collection of blood, separation of leukocytes from whole blood by lysis of erythrocytes, isolating mononuclear cells by density gradient separation, and assorted non-flow sorting methods, such as magnetic bead separations, for enriching specific cell populations, including monocytes, T lymphocytes, B lymphocytes, neutrophils,, , and platelets prior to flow cytometric analysis. A protocol is also offered for cryopreservation of cells since clinical research often involves retrospective flow cytometric analysis of samples stored over a period of months or years. PMID:26132177
Formalin preservation of avian blood for organochlorine analysis
Stafford, C.J.; Stickel, W.H.; Lamb, D.W.; Kenaga, E.E.
1981-01-01
Blood biopsy for chemical analysis is a valuable technique for evaluating chemical exposure of birds in the wild without harming the birds. Field conditions, however, often make sample storage difficult. Better methods than freezing are needed to improve the interpretive value of chemical analysis of the sample. The use of formalin was explored for this purpose. A pooled sample of blood containing naturally incorporated 1,1-bis-(p-chlorophenyl)-2,2,2-trichloroethane (DDT), 2,2-bis-(p-chlorophenyl)1,1 dichloroethylene (DDE), and dieldrin was subdivided into 30 samples, of which 10 were frozen, 10 more were kept at room temperature, and 10 were formalinized by adding I part of chemically pure formalin to 20 parts of blood. The formalinized samples yielded the highest and least variable concentrations of chemicals. The field procedures are outlined.
Cost-effectiveness analysis: what it really means for transfusion medicine decision making.
Custer, Brian; Hoch, Jeffrey S
2009-01-01
Some have suggested that "blood is different," and the role for cost-effectiveness is thus circumscribed. In this article, the authors start by reviewing key concepts in health economics and economic analysis methods. Examples are drawn from published blood safety studies. After explaining the underlying reasoning behind cost-effectiveness analysis, the authors point out how economic thinking is evident in some aspects of transfusion medicine. Some cost-effectiveness study results for blood safety are discussed to provide context, followed by consideration of prominent decisions that have been made in transfusion medicine field. In the last section, the authors conjecture as to why in some cases cost-effectiveness analysis appears to have greater impact than in others, noting the terrible price that is paid in mortality and morbidity when cost-effectiveness analysis is ignored. In this context, the implications of opportunity cost are discussed, and it is noted that opportunity cost should not be viewed as benefits forgone by concentrating on one aspect of blood safety and instead should be viewed as our societal willingness to misallocate resources to achieve less health for the same cost.
Computational Analysis of Human Blood Flow
NASA Astrophysics Data System (ADS)
Panta, Yogendra; Marie, Hazel; Harvey, Mark
2009-11-01
Fluid flow modeling with commercially available computational fluid dynamics (CFD) software is widely used to visualize and predict physical phenomena related to various biological systems. In this presentation, a typical human aorta model was analyzed assuming the blood flow as laminar with complaint cardiac muscle wall boundaries. FLUENT, a commercially available finite volume software, coupled with Solidworks, a modeling software, was employed for the preprocessing, simulation and postprocessing of all the models.The analysis mainly consists of a fluid-dynamics analysis including a calculation of the velocity field and pressure distribution in the blood and a mechanical analysis of the deformation of the tissue and artery in terms of wall shear stress. A number of other models e.g. T branches, angle shaped were previously analyzed and compared their results for consistency for similar boundary conditions. The velocities, pressures and wall shear stress distributions achieved in all models were as expected given the similar boundary conditions. The three dimensional time dependent analysis of blood flow accounting the effect of body forces with a complaint boundary was also performed.
Smith, André; Matthews, Ralph; Fiddler, Jay
2013-12-01
This study approaches the decision to donate blood as a dynamic process involving interplay between blood donors' personal motives, donors' social contexts, and the donor recruitment and retention activities of blood collection agencies. Data were gathered from four blood donation clinics using in-depth interviews with Canadian Blood Services employees, donors, and nondonors in 25 organizations participating in Life Link, a donor recruitment program that supports organizations to educate employees about the benefits of blood donation. Further data were obtained from ethnographic observations of blood collection and donor recruitment activities. Thematic analysis resulted in three umbrella themes: leveraging social networks, embedding the clinic in the community, and donating blood and social reciprocity. Donor recruitment activities at all four clinics enhanced awareness of blood donation in the workplace by using experienced donors to motivate their coworkers in making a first-time donation. Clinic employees reported varying success in improving awareness of blood donation in the broader community, in part because of varying employee engagement in community-wide activities and celebrations. Altruistic motives were mentioned by experienced donors, who also identified a desire to reciprocate to their community as another strong motive. This study contextualizes donor recruitment and retention as involving activities that tie blood donation to meaningful aspects of donors' social networks and community. The findings point to the need for further analyses of the institutional dimensions of blood donation to develop effective strategies beyond appeals to altruism. © 2013 American Association of Blood Banks.
The challenges of analysing blood stains with hyperspectral imaging
NASA Astrophysics Data System (ADS)
Kuula, J.; Puupponen, H.-H.; Rinta, H.; Pölönen, I.
2014-06-01
Hyperspectral imaging is a potential noninvasive technology for detecting, separating and identifying various substances. In the forensic and military medicine and other CBRNE related use it could be a potential method for analyzing blood and for scanning other human based fluids. For example, it would be valuable to easily detect whether some traces of blood are from one or more persons or if there are some irrelevant substances or anomalies in the blood. This article represents an experiment of separating four persons' blood stains on a white cotton fabric with a SWIR hyperspectral camera and FT-NIR spectrometer. Each tested sample includes standardized 75 _l of 100 % blood. The results suggest that on the basis of the amount of erythrocytes in the blood, different people's blood might be separable by hyperspectral analysis. And, referring to the indication given by erythrocytes, there might be a possibility to find some other traces in the blood as well. However, these assumptions need to be verified with wider tests, as the number of samples in the study was small. According to the study there also seems to be several biological, chemical and physical factors which affect alone and together on the hyperspectral analyzing results of blood on fabric textures, and these factors need to be considered before making any further conclusions on the analysis of blood on various materials.
Impact of Physical Activity Interventions on Blood Pressure in Brazilian Populations
Bento, Vivian Freitas Rezende; Albino, Flávia Barbizan; de Moura, Karen Fernandes; Maftum, Gustavo Jorge; dos Santos, Mauro de Castro; Guarita-Souza, Luiz César; Faria Neto, José Rocha; Baena, Cristina Pellegrino
2015-01-01
Background High blood pressure is associated with cardiovascular disease, which is the leading cause of mortality in the Brazilian population. Lifestyle changes, including physical activity, are important for lowering blood pressure levels and decreasing the costs associated with outcomes. Objective Assess the impact of physical activity interventions on blood pressure in Brazilian individuals. Methods Meta-analysis and systematic review of studies published until May 2014, retrieved from several health sciences databases. Seven studies with 493 participants were included. The analysis included parallel studies of physical activity interventions in adult populations in Brazil with a description of blood pressure (mmHg) before and after the intervention in the control and intervention groups. Results Of 390 retrieved studies, eight matched the proposed inclusion criteria for the systematic review and seven randomized clinical trials were included in the meta-analysis. Physical activity interventions included aerobic and resistance exercises. There was a reduction of -10.09 (95% CI: -18.76 to -1.43 mmHg) in the systolic and -7.47 (95% CI: -11.30 to -3.63 mmHg) in the diastolic blood pressure. Conclusions Available evidence on the effects of physical activity on blood pressure in the Brazilian population shows a homogeneous and significant effect at both systolic and diastolic blood pressures. However, the strength of the included studies was low and the methodological quality was also low and/or regular. Larger studies with more rigorous methodology are necessary to build robust evidence. PMID:26016783
Hong, Kun-Hao; Pan, Jian-Ke; Yang, Wei-Yi; Luo, Ming-Hui; Xu, Shu-Chai; Liu, Jun
2016-08-01
Autologous blood transfusion (ABT) drainage system is a new unwashed salvaged blood retransfusion system for total knee replacement (TKA). However, whether to use ABT drainage, closed-suction (CS) drainage or no drainage in TKA surgery remains controversial. This is the first meta-analysis to assess the clinical efficiency, safety and potential advantages regarding the use of ABT drains compared with closed-suction/no drainage. PubMed, Embase, and the Cochrane Library were comprehensively searched in March 2015. Fifteen randomized controlled trials (RCTs) were identified and pooled for statistical analysis. The primary outcome evaluated was homologous blood transfusion rate. The secondary outcomes were post-operative haemoglobin on days 3-5, length of hospital stay and wound infections after TKA surgery. The pooled data included 1,721 patients and showed that patients in the ABT drainage group might benefit from lower blood transfusion rates (16.59 % and 37.47 %, OR: 0.28 [0.14, 0.55]; 13.05 % and 16.91 %, OR: 0.73 [0.47,1.13], respectively). Autologous blood transfusion drainage and closed-suction drainage/no drainage have similar clinical efficacy and safety with regard to post-operative haemoglobin on days 3-5, length of hospital stay and wound infections. Autologous blood transfusion drainage offers a safe and efficient alternative to CS/no drainage with a lower blood transfusion rate. Future large-volume high-quality RCTs with extensive follow-up will affirm and update this system review.
DOT National Transportation Integrated Search
2002-01-01
The National Center for Statistics and Analysis (NCSA) of the National Highway Traffic Safety : Administration (NHTSA) has undertaken several approaches to remedy the problem of missing blood alcohol : test results in the Fatality Analysis Reporting ...
Linkage analysis of systolic blood pressure: a score statistic and computer implementation
Wang, Kai; Peng, Yingwei
2003-01-01
A genome-wide linkage analysis was conducted on systolic blood pressure using a score statistic. The randomly selected Replicate 34 of the simulated data was used. The score statistic was applied to the sibships derived from the general pedigrees. An add-on R program to GENEHUNTER was developed for this analysis and is freely available. PMID:14975145
More Young Adults at Risk for High Blood Pressure | NIH MedlinePlus the Magazine
... young adults have high blood pressure. NIH-funded analysis indicates higher risk for young adults than previously ... DASH) clinical study, which tested the effects of food nutrients on blood pressure. It emphasizes consumption of ...
Lu, Jun; Meng, Haoyu; Meng, Zhaoyi; Sun, Ying; Pribis, John P; Zhu, Chunyan; Li, Quan
2015-01-01
Background: Excessive postoperative blood loss after cardiopulmonary bypass is a common problem, especially in patients suffering from congenital heart diseases. The efficacy of epsilon aminocaproic acid (EACA) as a prophylactic treatment for postoperative bleeding after pediatric open-heart surgery has not been determined. This meta-analysis investigates the efficacy of EACA in the minimization of bleeding and blood transfusion and the maintenance of coagulation tests after pediatric open-heart surgery. Methods: A comprehensive literature search was performed to identify all randomized clinical trials on the subject. PubMed, Embase, the Cochrane Library, and the Chinese Medical Journal Network were screened. The primary outcome used for the analysis was postoperative blood loss. Secondary outcomes included postoperative blood transfusion, re-exploration rate and postoperative coagulation tests. The mean difference (MD) and risk ratio (RR) with 95% confidence intervals (CI) were used as summary statistics. Results: Five trials were included in this meta-analysis of 515 patients. Prophylactic EACA was associated with a reduction in postoperative blood loss, but this difference did not reach statistical significance (MD: -7.08; 95% CI: -16.11 to 1.95; P = 0.12). Patients treated with EACA received fewer postoperative blood transfusions, including packed red blood cells (MD: -8.36; 95% CI: -12.63 to -4.09; P = 0.0001), fresh frozen plasma (MD: -3.85; 95% CI: -5.63 to -2.08; P < 0.0001), and platelet concentrate (MD: -10.66; 95% CI: -18.45 to -2.87; P = 0.007), and had a lower re-exploration rate (RR: 0.46; 95% CI: 0.23 to 0.92; P = 0.03). Prophylactic EACA also improved coagulation tests 6 hours after open-heart surgery. Conclusions: Prophylactic EACA minimizes postoperative blood transfusion and helps maintain coagulation in pediatric patients undergoing open-heart surgery. Therefore, the results of this study indicate that adjunctive EACA is a good choice for the prevention of postoperative blood transfusion following pediatric cardiac surgery. PMID:26339364
Analysis of Hepatic Blood Flow Using Chaotic Models
Cohen, M. E.; Moazamipour, H.; Hudson, D. L.; Anderson, M. F.
1990-01-01
The study of chaos in physical systems is an important new theoretical development in modeling which has emerged in the last fifteen years. It is particularly useful in explaining phenomena which arise in nonlinear dynamic systems, for which previous mathematical models produced results with intractable solutions. Analysis of blood flow is such an application. In the work described here, chaotic models are used to analyze hepatic artery and portal vein blood flow obtained from a pulsed Doppler ultrasonic flowmeter implanted in dogs. ImagesFigure 3
Systematic RH genotyping and variant identification in French donors of African origin
Kappler-Gratias, Sandrine; Auxerre, Carine; Dubeaux, Isabelle; Beolet, Marylise; Ripaux, Maryline; Le Pennec, Pierre-Yves; Pham, Bach-Nga
2014-01-01
Background RH molecular analysis has enabled the documentation of numerous variants of RHD and RHCE alleles, especially in individuals of African origin. The aim of the present study was to determine the type and frequency of D and/or RhCE variants among blood donors of African origin in France, by performing a systematic RH molecular analysis, in order to evaluate the implications for blood transfusion of patients of African origin. Materials and methods Samples from 316 African blood donors, whose origin was established by their Fy(a−b−) phenotype, were first analysed using the RHD and RHCE BeadChips Kit (BioArray Solutions, Immucor, Warren, NJ, USA). Sequencing was performed when necessary. Results RHD molecular analysis showed that 26.2% of donors had a variant RHD allele. It allowed the prediction of a partial D in 11% of cases. RHCE molecular analysis showed that 14.2% of donors had a variant RHCE allele or RH [RN or (C)ces] haplotype. A rare Rh phenotype associated with the loss of a high-prevalence antigen or partial RhCE antigens were predicted from RHCE molecular analysis in 1 (0.3%) and 17 (5%) cases, respectively. Discussion Systematic RHD and RHCE molecular analysis performed in blood donors of African origin provides transfusion-relevant information for individuals of African origin because of the frequency of variant RH alleles. RH molecular analysis may improve transfusion therapy of patients by allowing better donor and recipient matching, based not only on phenotypically matched red blood cell units, but also on units that are genetically matched with regards to RhCE variants. PMID:23867180
Oosterwijk, J C; Knepflé, C F; Mesker, W E; Vrolijk, H; Sloos, W C; Pattenier, H; Ravkin, I; van Ommen, G J; Kanhai, H H; Tanke, H J
1998-01-01
This article explores the feasibility of the use of automated microscopy and image analysis to detect the presence of rare fetal nucleated red blood cells (NRBCs) circulating in maternal blood. The rationales for enrichment and for automated image analysis for "rare-event" detection are reviewed. We also describe the application of automated image analysis to 42 maternal blood samples, using a protocol consisting of one-step enrichment followed by immunocytochemical staining for fetal hemoglobin (HbF) and FISH for X- and Y-chromosomal sequences. Automated image analysis consisted of multimode microscopy and subsequent visual evaluation of image memories containing the selected objects. The FISH results were compared with the results of conventional karyotyping of the chorionic villi. By use of manual screening, 43% of the slides were found to be positive (>=1 NRBC), with a mean number of 11 NRBCs (range 1-40). By automated microscopy, 52% were positive, with on average 17 NRBCs (range 1-111). There was a good correlation between both manual and automated screening, but the NRBC yield from automated image analysis was found to be superior to that from manual screening (P=.0443), particularly when the NRBC count was >15. Seven (64%) of 11 XY fetuses were correctly diagnosed by FISH analysis of automatically detected cells, and all discrepancies were restricted to the lower cell-count range. We believe that automated microscopy and image analysis reduce the screening workload, are more sensitive than manual evaluation, and can be used to detect rare HbF-containing NRBCs in maternal blood. PMID:9837832
Cinnamon intake lowers fasting blood glucose: an updated meta-analysis
USDA-ARS?s Scientific Manuscript database
OBJECTIVE – To determine if meta-analysis of recent clinical studies of cinnamon intake by people with Type II diabetes and/or prediabetes resulted in significant changes in fasting blood glucose. RESEARCH DESIGN AND METHODS -- Published clinical studies were identified using a literature search (P...
2014-01-01
Protein biomarkers offer major benefits for diagnosis and monitoring of disease processes. Recent advances in protein mass spectrometry make it feasible to use this very sensitive technology to detect and quantify proteins in blood. To explore the potential of blood biomarkers, we conducted a thorough review to evaluate the reliability of data in the literature and to determine the spectrum of proteins reported to exist in blood with a goal of creating a Federated Database of Blood Proteins (FDBP). A unique feature of our approach is the use of a SQL database for all of the peptide data; the power of the SQL database combined with standard informatic algorithms such as BLAST and the statistical analysis system (SAS) allowed the rapid annotation and analysis of the database without the need to create special programs to manage the data. Our mathematical analysis and review shows that in addition to the usual secreted proteins found in blood, there are many reports of intracellular proteins and good agreement on transcription factors, DNA remodelling factors in addition to cellular receptors and their signal transduction enzymes. Overall, we have catalogued about 12,130 proteins identified by at least one unique peptide, and of these 3858 have 3 or more peptide correlations. The FDBP with annotations should facilitate testing blood for specific disease biomarkers. PMID:24476026
Chassé, Michaël; McIntyre, Lauralyn; Tinmouth, Alan; Acker, Jason; English, Shane W; Knoll, Greg; Forster, Alan; Shehata, Nadine; Wilson, Kumanan; van Walraven, Carl; Ducharme, Robin; Fergusson, Dean A
2015-01-01
Introduction When used appropriately, transfusion of red blood cells (RBCs) is a necessary life-saving therapy. However, RBC transfusions have been associated with negative outcomes such as infection and organ damage. Seeking explanations for the beneficial and deleterious effects of RBC transfusions is necessary to ensure the safe and optimal use of this precious resource. This study will create a framework to analyse the influence of blood donor characteristics on recipient outcomes. Methods and analysis We will conduct a multisite, longitudinal cohort study using blood donor data routinely collected by Canadian Blood Services, and recipient data from health administrative databases. Our project will include a thorough validation of primary data, the linkage of various databases into one large longitudinal database, an in-depth epidemiological analysis and a careful interpretation and dissemination of the results to assist the decision-making process of clinicians, researchers and policymakers in transfusion medicine. Our primary donor characteristic will be age of blood donors and our secondary donor characteristics will be donor–recipient blood group compatibility and blood donor sex. Our primary recipient outcome will be a statistically appropriate survival analysis post-RBC transfusion up to a maximum of 8 years. Our secondary recipient outcomes will include 1-year, 2-year and 5-year mortality; hospital and intensive care unit length of stay; rehospitalisation; new cancer and cancer recurrence rate; infection rate; new occurrence of myocardial infarctions and need for haemodialysis. Ethics and dissemination Our results will help determine whether we need to tailor transfusion based on donor characteristics, and perhaps this will improve patient outcome. Our results will be customised to target the different stakeholders involved with blood transfusions and will include presentations, peer-reviewed publications and the use of the dissemination network of blood supply organisations. We obtained approval from the Research Ethics boards and privacy offices of all involved institutions. PMID:25600255
Li, Bingsheng; Gan, Aihua; Chen, Xiaolong; Wang, Xinying; He, Weifeng; Zhang, Xiaohui; Huang, Renxiang; Zhou, Shuzhu; Song, Xiaoxiao; Xu, Angao
2016-01-01
DNA hypermethylation in blood is becoming an attractive candidate marker for colorectal cancer (CRC) detection. To assess the diagnostic accuracy of blood hypermethylation markers for CRC in different clinical settings, we conducted a meta-analysis of published reports. Of 485 publications obtained in the initial literature search, 39 studies were included in the meta-analysis. Hypermethylation markers in peripheral blood showed a high degree of accuracy for the detection of CRC. The summary sensitivity was 0.62 [95% confidence interval (CI), 0.56–0.67] and specificity was 0.91 (95% CI, 0.89–0.93). Subgroup analysis showed significantly greater sensitivity for the methylated Septin 9 gene (SEPT9) subgroup (0.75; 95% CI, 0.67–0.81) than for the non-methylated SEPT9 subgroup (0.58; 95% CI, 0.52–0.64). Sensitivity and specificity were not affected significantly by target gene number, CRC staging, study region, or methylation analysis method. These findings show that hypermethylation markers in blood are highly sensitive and specific for CRC detection, with methylated SEPT9 being particularly robust. The diagnostic performance of hypermethylation markers, which have varied across different studies, can be improved by marker optimization. Future research should examine variation in diagnostic accuracy according to non-neoplastic factors. PMID:27158984
Ren, Jian-xun; Liu, Jian-xun; Lin, Cheng-ren
2010-04-01
To comparatively analyse the objective characteristics of different syndrome types of qi-disturbance-induced blood stasis syndrome (QDBS) in the pathogenetic evolution of unstable angina coronary heart disease (UA-CHD). Seventy-eight patients with UA-CHD of QDBS were differentiated into 2 groups: 55 in the qi-deficiency-induced blood-stasis syndrome group (A) and 23 in the qi-stagnation-induced blood-stasis syndrome group (B). The comparative analysis on them was carried out through comparing their blood pressure, glucose and lipid metabolisms, coagulation function, thyroid function and inflammation reaction changes, etc. In the pathogenetic process of qi-disturbance induced blood stasis, the initiating age, levels of HbA1c, TSH, PT and APTT between the two groups were significantly different (P < 0.05). Levels of TNF-alpha and LN were higher and levels of sIgA lower in patients than those in healthy subjects (P < 0.05). Inflammation immune reaction may play an important role in the pathogenetic process of blood-stasis syndrome, and the functional disturbance of hypothalamus, pituitary and endocrinal secretion induced by emotional stress is possibly the essence of qi-stagnation induced blood stasis syndrome.
Finite Element Analysis of Stresses Developed in the Blood Sac of a Left Ventricular Assist Device
Haut Donahue, T. L.; Dehlin, W.; Gillespie, J.; Weiss, W.J.; Rosenberg, G.
2009-01-01
The goal of this research is to develop a 3D finite element (FE) model of a left ventricular assist device (LVAD) to predict stresses in the blood sac. The hyperelastic stress-strain curves for the segmented poly(ether polyurethane urea) blood sac were determined in both tension and compression using a servo-hydraulic testing system at various strain rates. Over the range of strain rates studied, the sac was not strain rate sensitive, however the material response was different for tension versus compression. The experimental tension and compression properties were used in a FE model that consisted of the pusher plate, blood sac and pump case. A quasi-static analysis was used to allow for nonlinearities due to contact and material deformation. The 3D FE model showed that blood sac stresses are not adversely affected by the location of the inlet and outlet ports of the device and that over the systolic ejection phase of the simulation the prediction of blood sac stresses from the full 3D model and an axisymmetric model are the same. Minimizing stresses in the blood sac will increase the longevity of the blood sac in vivo. PMID:19131267
[Breast feeding and systemic blood pressure in infants].
Hernández-González, Martha A; Díaz-De-León, Luz V; Guízar-Mendoza, Juan M; Amador-Licona, Norma; Cipriano-González, Marisol; Díaz-Pérez, Raúl; Murillo-Ortiz, Blanca O; De-la-Roca-Chiapas, José María; Solorio-Meza, Sergio Eduardo
2012-01-01
Blood pressure levels in childhood influence these levels in adulthood, and breastfeeding has been considered such as a cardioprotective. We evaluated the association between blood pressure levels and feeding type in a group of infants. We conducted a comparative cross-sectional study in term infants with appropriate weight at birth, to compare blood pressure levels in those children with exclusively breastfeeding, mixed-feeding and formula feeding. The comparison of groups was performed using ANOVA and multiple regression analysis was used to identify variables associated with mean arterial blood pressure levels. A p value < 0.05 was considered significant. We included 20 men and 24 women per group. Infant Formula Feeding had higher current weight and weight gain compared with the other two groups (p < 0.05). Systolic, diastolic and mean blood pressure levels, as well as respiratory and heart rate were higher in the groups of exclusively formula feeding and mixed-feeding than in those with exclusively breastfeeding (p < 0.05). Multiple regression analysis identified that variables associated with mean blood pressure levels were current body mass index, weight gain and formula feeding. Infants in breastfeeding show lower blood pressure, BMI and weight gain.
Balter, Max L; Chen, Alvin I; Fromholtz, Alex; Gorshkov, Alex; Maguire, Tim J; Yarmush, Martin L
2016-10-01
Diagnostic blood testing is the most prevalent medical procedure performed in the world and forms the cornerstone of modern health care delivery. Yet blood tests are still predominantly carried out in centralized labs using large-volume samples acquired by manual venipuncture, and no end-to-end solution from blood draw to sample analysis exists today. Our group is developing a platform device that merges robotic phlebotomy with automated diagnostics to rapidly deliver patient information at the site of the blood draw. The system couples an image-guided venipuncture robot, designed to address the challenges of routine venous access, with a centrifuge-based blood analyzer to obtain quantitative measurements of hematology. In this paper, we first present the system design and architecture of the integrated device. We then perform a series of in vitro experiments to evaluate the cannulation accuracy of the system on blood vessel phantoms. Next, we assess the effects of vessel diameter, needle gauge, flow rate, and viscosity on the rate of sample collection. Finally, we demonstrate proof-of-concept of a white cell assay on the blood analyzer using in vitro human samples spiked with fluorescently labeled microbeads.
Narayanan, S; Orton, S; Leparc, G F; Garcia-Rubio, L H; Potter, R L
1999-10-01
A new blood typing technology based on ultraviolet (UV) and visible light spectroscopy (UV/visible spectroscopy) has been developed. Blood groups and types are determined by quantifying reproducible changes in the UV and visible light spectra of blood in the presence of agglutinating antibodies. Samples of red cells in the presence and absence of agglutinating antibodies were examined by UV/visible spectroscopy. Blood groups and types were determined by comparing the optical density spectra obtained between 665 and 1000 nm. These comparisons generate numbers (agglutination index) ranging from 0 to 100, with smaller numbers corresponding to lack of agglutination and larger numbers corresponding to agglutination. The optical density of agglutinated blood is dramatically different from that of unagglutinated blood. The agglutination index derived from the relative slopes of the spectra is an objective indicator of agglutination strength. An agglutination index greater than 17 consistently and accurately established blood group- and type-specific agglutination. The method accurately predicted A, B, and O blood groups, and D type in over 275 samples. Scattering theory-based calculations of relative volumes of red cells before and after agglutination show a direct correlation with the agglutination index and provide the theoretical basis of the analysis. This quantitative technique is reproducible and has the potential for automation.
A porous media theory for characterization of membrane blood oxygenation devices
NASA Astrophysics Data System (ADS)
Sano, Yoshihiko; Adachi, Jun; Nakayama, Akira
2013-07-01
A porous media theory has been proposed to characterize oxygen transport processes associated with membrane blood oxygenation devices. For the first time, a rigorous mathematical procedure based a volume averaging procedure has been presented to derive a complete set of the governing equations for the blood flow field and oxygen concentration field. As a first step towards a complete three-dimensional numerical analysis, one-dimensional steady case is considered to model typical membrane blood oxygenator scenarios, and to validate the derived equations. The relative magnitudes of oxygen transport terms are made clear, introducing a dimensionless parameter which measures the distance the oxygen gas travels to dissolve in the blood as compared with the blood dispersion length. This dimensionless number is found so large that the oxygen diffusion term can be neglected in most cases. A simple linear relationship between the blood flow rate and total oxygen transfer rate is found for oxygenators with sufficiently large membrane surface areas. Comparison of the one-dimensional analytic results and available experimental data reveals the soundness of the present analysis.
A new model of arterial hemodynamics.
Branzan, M; Sundri, G
1983-01-01
The determination of arterial blood flow parameters on the basis of ultrasound investigation requires a new hydrodynamic model of arterial circulation. Unlike previous research (Womersley, Bergel) considering the arterial pressure of its gradients to be known, the present model uses blood flow velocity and arterial radius magnitude easily obtained by ultrasound (Doppler effect). Processing these data requires the thorough analysis of rheological characteristics of blood flow and of arterial wall behaviour (elastic deformability). It has been assumed that: a) blood is a homogeneous and isotropic fluid; b) the artery has a cylindrical symmetry of a circular cross-section at any time moment; c) the pressure in the artery cross-section is constant. Because arterial dynamics has an undulatory character the Fourier analysis of the modified Navier-Stokes equations has been used. Finally, a simplified relation for blood pressure determination has been obtained.
The antenna transcriptome changes in mosquito Anopheles sinensis, pre- and post- blood meal.
Chen, Qian; Pei, Di; Li, Jianyong; Jing, Chengyu; Wu, Wenjian; Man, Yahui
2017-01-01
Antenna is the main chemosensory organ in mosquitoes. Characterization of the transcriptional changes after blood meal, especially those related to chemoreception, may help to explain mosquito blood sucking behavior and to identify novel targets for mosquito control. Anopheles sinensis is an Asiatic mosquito species which transmits malaria and lymphatic filariasis. However, studies on chemosensory biology in female An. sinensis are quite lacking. Here we report a transcriptome analysis of An. sinensis female antennae pre- and post- blood meal. We created six An. sinensis antenna RNA-seq libraries, three from females without blood meal and three from females five hours after a blood meal. Illumina sequencing was conducted to analyze the transcriptome differences between the two groups. In total, the sequenced fragments created 21,643 genes, 1,828 of them were novel. 12,861 of these genes were considered to be expressed (FPKM >1.0) in at least one of the two groups, with 12,159 genes expressed in both groups. 548 genes were differentially expressed in the blood-fed group, with 331 genes up-regulated and 217 genes down-regulated. GO enrichment analysis of the differentially expressed genes suggested that there were no statistically over represented GO terms among down-regulated genes in blood-fed mosquitoes, while the enriched GO terms of the up-regulated genes occurred mainly in metabolic process. For the chemosensory gene families, a subtle distinction in the expression levels can be observed according to our statistical analysis. However, the firstly comprehensive identification of these chemosensory gene families in An. sinensis antennae will help to characterize the precise function of these proteins in odor recognition in mosquitoes. This study provides a first global view in the changes of transcript accumulation elicited by blood meal in An. sinensis female antennae.
Sandset, Else Charlotte; Sanossian, Nerses; Woodhouse, Lisa J; Anderson, Craig; Berge, Eivind; Lees, Kennedy R; Potter, John F; Robinson, Thompson G; Sprigg, Nikola; Wardlaw, Joanna M; Bath, Philip M
2018-01-01
Rationale Despite several large clinical trials assessing blood pressure lowering in acute stroke, equipoise remains particularly for ischemic stroke. The "Blood pressure in Acute Stroke Collaboration" commenced in the mid-1990s focussing on systematic reviews and meta-analysis of blood pressure lowering in acute stroke. From the start, Blood pressure in Acute Stroke Collaboration planned to assess safety and efficacy of blood pressure lowering in acute stroke using individual patient data. Aims To determine the optimal management of blood pressure in patients with acute stroke, including both intracerebral hemorrhage and ischemic stroke. Secondary aims are to assess which clinical and therapeutic factors may alter the optimal management of high blood pressure in patients with acute stroke and to assess the effect of vasoactive treatments on hemodynamic variables. Methods and design Individual patient data from randomized controlled trials of blood pressure management in participants with ischemic stroke and/or intracerebral hemorrhage enrolled during the ultra-acute (pre-hospital), hyper-acute (<6 h), acute (<48 h), and sub-acute (<168 h) phases of stroke. Study outcomes The primary effect variable will be functional outcome defined by the ordinal distribution of the modified Rankin Scale; analyses will also be carried out in pre-specified subgroups to assess the modifying effects of stroke-related and pre-stroke patient characteristics. Key secondary variables will include clinical, hemodynamic and neuroradiological variables; safety variables will comprise death and serious adverse events. Discussion Study questions will be addressed in stages, according to the protocol, before integrating these into a final overreaching analysis. We invite eligible trials to join the collaboration.
Li, Yueying; Liu, Tie; Van Halm-Lutterodt, Nicholas; Chen, JiaYu; Su, Qingjun; Hai, Yong
2016-02-17
An attempt was made to reprogram peripheral blood cells into human induced pluripotent stem cell (hiPSCs) as a new cell source for cartilage repair. We generated chondrogenic lineage from human peripheral blood via hiPSCs using an integration-free method. Peripheral blood cells were either obtained from a human blood bank or freshly collected from volunteers. After transforming peripheral blood cells into iPSCs, the newly derived iPSCs were further characterized through karyotype analysis, pluripotency gene expression and cell differentiation ability. iPSCs were differentiated through multiple steps, including embryoid body formation, hiPSC-mesenchymal stem cell (MSC)-like cell expansion, and chondrogenic induction for 21 days. Chondrocyte phenotype was then assessed by morphological, histological and biochemical analysis, as well as the chondrogenic expression. hiPSCs derived from peripheral blood cells were successfully generated, and were characterized by fluorescent immunostaining of pluripotent markers and teratoma formation in vivo. Flow cytometric analysis showed that MSC markers CD73 and CD105 were present in monolayer cultured hiPSC-MSC-like cells. Both alcian blue and toluidine blue staining of hiPSC-MSC-chondrogenic pellets showed as positive. Immunohistochemistry of collagen II and X staining of the pellets were also positive. The sulfated glycosaminoglycan content was significantly increased, and the expression levels of the chondrogenic markers COL2, COL10, COL9 and AGGRECAN were significantly higher in chondrogenic pellets than in undifferentiated cells. These results indicated that peripheral blood cells could be a potential source for differentiation into chondrogenic lineage in vitro via generation of mesenchymal progenitor cells. This study supports the potential applications of utilizing peripheral blood cells in generating seed cells for cartilage regenerative medicine in a patient-specific and cost-effective approach.
Image processing and machine learning in the morphological analysis of blood cells.
Rodellar, J; Alférez, S; Acevedo, A; Molina, A; Merino, A
2018-05-01
This review focuses on how image processing and machine learning can be useful for the morphological characterization and automatic recognition of cell images captured from peripheral blood smears. The basics of the 3 core elements (segmentation, quantitative features, and classification) are outlined, and recent literature is discussed. Although red blood cells are a significant part of this context, this study focuses on malignant lymphoid cells and blast cells. There is no doubt that these technologies may help the cytologist to perform efficient, objective, and fast morphological analysis of blood cells. They may also help in the interpretation of some morphological features and may serve as learning and survey tools. Although research is still needed, it is important to define screening strategies to exploit the potential of image-based automatic recognition systems integrated in the daily routine of laboratories along with other analysis methodologies. © 2018 John Wiley & Sons Ltd.
Drop coating deposition Raman spectroscopy of blood plasma for the detection of colorectal cancer
NASA Astrophysics Data System (ADS)
Li, Pengpeng; Chen, Changshui; Deng, Xiaoyuan; Mao, Hua; Jin, Shaoqin
2015-03-01
We have recently applied the technique of drop coating deposition Raman (DCDR) spectroscopy for colorectal cancer (CRC) detection using blood plasma. The aim of this study was to develop a more convenient and stable method based on blood plasma for noninvasive CRC detection. Significant differences are observed in DCDR spectra between healthy (n=105) and cancer (n=75) plasma from 15 CRC patients and 21 volunteers, particularly in the spectra that are related to proteins, nucleic acids, and β-carotene. The multivariate analysis principal components analysis and the linear discriminate analysis, together with leave-one-out, cross validation were used on DCDR spectra and yielded a sensitivity of 100% (75/75) and specificity of 98.1% (103/105) for detection of CRC. This study demonstrates that DCDR spectroscopy of blood plasma associated with multivariate statistical algorithms has the potential for the noninvasive detection of CRC.
The frequency and severity of metabolic acidosis related to topiramate.
Türe, Hatice; Keskin, Özgül; Çakır, Ülkem; Aykut Bingöl, Canan; Türe, Uğur
2016-12-01
Objective We planned a cross-sectional analysis to determine the frequency and severity of metabolic acidosis in patients taking topiramate while awaiting craniotomy. Methods Eighty patients (18 - 65 years) taking topiramate to control seizures while awaiting elective craniotomy were enrolled. Any signs of metabolic acidosis or topiramate-related side effects were investigated. Blood chemistry levels and arterial blood gases, including lactate, were obtained. The severity of metabolic acidosis was defined according to base excess levels as mild or moderate. Results Blood gas analysis showed that 71% ( n = 57) of patients had metabolic acidosis. The frequency of moderate metabolic acidosis was 56% ( n = 45), while that of mild metabolic acidosis was 15% ( n = 12). A high respiratory rate was reported in only 10% of moderately acidotic patients. Conclusions In patients receiving topiramate, baseline blood gas analysis should be performed preoperatively to determine the presence and severity of metabolic acidosis.
Fiber-optic evanescent-wave spectroscopy for fast multicomponent analysis of human blood
NASA Astrophysics Data System (ADS)
Simhi, Ronit; Gotshal, Yaron; Bunimovich, David; Katzir, Abraham; Sela, Ben-Ami
1996-07-01
A spectral analysis of human blood serum was undertaken by fiber-optic evanescent-wave spectroscopy (FEWS) by the use of a Fourier-transform infrared spectrometer. A special cell for the FEWS measurements was designed and built that incorporates an IR-transmitting silver halide fiber and a means for introducing the blood-serum sample. Further improvements in analysis were obtained by the adoption of multivariate calibration techniques that are already used in clinical chemistry. The partial least-squares algorithm was used to calculate the concentrations of cholesterol, total protein, urea, and uric acid in human blood serum. The estimated prediction errors obtained (in percent from the average value) were 6% for total protein, 15% for cholesterol, 30% for urea, and 30% for uric acid. These results were compared with another independent prediction method that used a neural-network model. This model yielded estimated prediction errors of 8.8% for total protein, 25% for cholesterol, and 21% for uric acid. spectroscopy, fiber-optic evanescent-wave spectroscopy, Fourier-transform infrared spectrometer, blood, multivariate calibration, neural networks.
Specific factors for prenatal lead exposure in the border area of China.
Kawata, Kimiko; Li, Yan; Liu, Hao; Zhang, Xiao Qin; Ushijima, Hiroshi
2006-07-01
The objectives of this study are to examine the prevalence of increased blood lead concentrations in mothers and their umbilical cords, and to identify risk factors for prenatal lead exposure in Kunming city, Yunnan province, China. The study was conducted at two obstetrics departments, and 100 peripartum women were enrolled. The mean blood lead concentrations of the mothers and the umbilical cords were 67.3microg/l and 53.1microg/l, respectively. In multiple linear regression analysis, maternal occupational exposure, maternal consumption of homemade dehydrated vegetables and maternal habitation period in Kunming city were significantly associated with an increase of umbilical cord blood lead concentration. In addition, logistic regression analysis was used to assess the association of umbilical cord blood lead concentrations that possibly have adverse effects on brain development of newborns with each potential risk factor. Maternal frequent use of tableware with color patterns inside was significantly associated with higher cord blood lead concentration in addition to the three items in the multiple linear regression analysis. These points should be considered as specific recommendations for maternal and fetal lead exposure in this city.
The principles of quality-associated costing: derivation from clinical transfusion practice.
Trenchard, P M; Dixon, R
1997-01-01
As clinical transfusion practice works towards achieving cost-effectiveness, prescribers of blood and its derivatives must be certain that the prices of such products are based on real manufacturing costs and not market forces. Using clinical cost-benefit analysis as the context for the costing and pricing of blood products, this article identifies the following two principles: (1) the product price must equal the product cost (the "price = cost" rule) and (2) the product cost must equal the real cost of product manufacture. In addition, the article describes a new method of blood product costing, quality-associated costing (QAC), that will enable valid cost-benefit analysis of blood products.
System of Mueller-Jones matrix polarizing mapping of blood plasma films in breast pathology
NASA Astrophysics Data System (ADS)
Zabolotna, Natalia I.; Radchenko, Kostiantyn O.; Tarnovskiy, Mykola H.
2017-08-01
The combined method of Jones-Mueller matrix mapping and blood plasma films analysis based on the system that proposed in this paper. Based on the obtained data about the structure and state of blood plasma samples the diagnostic conclusions can be make about the state of breast cancer patients ("normal" or "pathology"). Then, by using the statistical analysis obtain statistical and correlational moments for every coordinate distributions; these indicators are served as diagnostic criterias. The final step is to comparing results and choosing the most effective diagnostic indicators. The paper presents the results of Mueller-Jones matrix mapping of optically thin (attenuation coefficient ,τ≤0,1) blood plasma layers.
[Finite Element Analysis of Intravascular Stent Based on ANSYS Software].
Shi, Gengqiang; Song, Xiaobing
2015-10-01
This paper adopted UG8.0 to bulid the stent and blood vessel models. The models were then imported into the finite element analysis software ANSYS. The simulation results of ANSYS software showed that after endothelial stent implantation, the velocity of the blood was slow and the fluctuation of velocity was small, which meant the flow was relatively stable. When blood flowed through the endothelial stent, the pressure gradually became smaller, and the range of the pressure was not wide. The endothelial shear stress basically unchanged. In general, it can be concluded that the endothelial stents have little impact on the flow of blood and can fully realize its function.
ABO blood grouping: A potential risk factor for early childhood caries - A cross-sectional study.
Govindaraju, Lavanya; Jeevanandan, Ganesh; Subramanian, E M G
2018-01-01
The paradigm of etiology of early childhood caries (ECC) is shifting toward genetics. Of various inherited factors, blood group of an individual is genetically determined. The aim of the study is to determine if blood group of an individual will serve as a potential risk factor in the development of ECC. A cross-sectional study was conducted in Chennai. Blood samples were collected from a total of 500 children <71 months of age for determination of the blood group. Of which 96 children (24 per blood group) were randomly selected and were included in the study. Oral screening of the selected children was done by a pediatric dentist who was blinded to the blood group of the children. Decayed, extracted, and filling index was noted. Details on other associated factors for the development of ECC such as the socioeconomic status, oral hygiene measures, diet, and feeding practices were collected by directly interviewing the parents through a questionnaire. Statistical analysis was done using Chi-square and Kruskal-Wallis test and post hoc Tukey test with significance level set at 0.05. Intergroup analysis of the associated factors showed no significant differences between the children of different blood groups. A statistically significant relation was noted between the blood groups and development of ECC (P = 0.025). Blood group is a potential risk indicator for the development of ECC.
Algorithm-based arterial blood sampling recognition increasing safety in point-of-care diagnostics.
Peter, Jörg; Klingert, Wilfried; Klingert, Kathrin; Thiel, Karolin; Wulff, Daniel; Königsrainer, Alfred; Rosenstiel, Wolfgang; Schenk, Martin
2017-08-04
To detect blood withdrawal for patients with arterial blood pressure monitoring to increase patient safety and provide better sample dating. Blood pressure information obtained from a patient monitor was fed as a real-time data stream to an experimental medical framework. This framework was connected to an analytical application which observes changes in systolic, diastolic and mean pressure to determine anomalies in the continuous data stream. Detection was based on an increased mean blood pressure caused by the closing of the withdrawal three-way tap and an absence of systolic and diastolic measurements during this manipulation. For evaluation of the proposed algorithm, measured data from animal studies in healthy pigs were used. Using this novel approach for processing real-time measurement data of arterial pressure monitoring, the exact time of blood withdrawal could be successfully detected retrospectively and in real-time. The algorithm was able to detect 422 of 434 (97%) blood withdrawals for blood gas analysis in the retrospective analysis of 7 study trials. Additionally, 64 sampling events for other procedures like laboratory and activated clotting time analyses were detected. The proposed algorithm achieved a sensitivity of 0.97, a precision of 0.96 and an F1 score of 0.97. Arterial blood pressure monitoring data can be used to perform an accurate identification of individual blood samplings in order to reduce sample mix-ups and thereby increase patient safety.
Distribution of ABO Blood Groups and Coronary Artery Calcium.
Wang, Yao; Zhou, Bing-Yang; Zhu, Cheng-Gang; Guo, Yuan-Lin; Wu, Na-Qiong; Qing, Ping; Gao, Ying; Liu, Geng; Dong, Qian; Li, Jian-Jun
2017-06-01
ABO blood groups have been confirmed to be associated with cardiovascular diseases such as coronary artery disease. However, whether ABO blood group is correlated with coronary artery calcium (CAC) is still unknown. 301 patients with coronary artery calcium score (CACS) assessed by computed tomography were consecutively enrolled and divided into two groups: with calcium group (CACS>0, n=104) and without calcium group (CACS=0, n=197). Distribution of ABO blood groups was evaluated between the two groups. The percentage of A blood type was significantly higher (p=0.008) and O blood type was significantly lower (p=0.037) in the calcium group. Univariate regression analysis showed that age, total cholesterol, low density lipoprotein cholesterol, high-sensitivity C-reactive protein, A blood type were positively correlated with CAC, and O blood type was inversely associated with CAC. Multivariate regression analysis showed that A blood type was independently associated with CAC (odds ratio: 2.217, 95% confidence interval: 1.260-3.900, p=0.006) even after further adjustment for variables that were clearly different between the two groups. Our data has suggested for the first time that A blood type was an independent risk marker for CAC. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Byung-Kook; Kim, Yangho, E-mail: yanghokm@nuri.net
Introduction: We present data on the association of manganese (Mn) level with hypertension in a representative sample of the adult Korean population who participated in the Korean National Health and Nutrition Examination Survey (KNHANES) 2008. Methods: This study was based on the data obtained by KNHANES 2008, which was conducted for three years (2007-2009) using a rolling sampling design involving a complex, stratified, multistage, probability-cluster survey of a representative sample of the noninstitutionalized civilian population of South Korea. Results: Multiple regression analysis after controlling for covariates, including gender, age, regional area, education level, smoking, drinking status, hemoglobin, and serum creatinine,more » showed that the beta coefficients of log blood Mn were 3.514, 1.878, and 2.517 for diastolic blood pressure, and 3.593, 2.449, and 2.440 for systolic blood pressure in female, male, and all participants, respectively. Multiple regression analysis including three other blood metals, lead, mercury, and cadmium, revealed no significant effects of the three metals on blood pressure and showed no effect on the association between blood Mn and blood pressure. In addition, doubling the blood Mn increased the risk of hypertension 1.828, 1.573, and 1.567 fold in women, men, and all participants, respectively, after adjustment for covariates. The addition of blood lead, mercury, and cadmium as covariates did not affect the association between blood Mn and the prevalence of hypertension. Conclusion: Blood Mn level was associated with an increased risk of hypertension in a representative sample of the Korean adult population. - Highlights: {yields} We showed the association of manganese with hypertension in Korean population. {yields} This study was based on the data obtained by KNHANES 2008. {yields} Blood manganese level was associated with an increased risk of hypertension.« less
[Analysis for Discordance of Positive and Negative Blood Typing by Gel Card].
Li, Cui-Ying; Xu, Hong; Lei, Hui-Fen; Liu, Juan; Li, Xiao-Wei
2017-08-01
To explore the method of Gel card identifying ABO blood group, determine the inconsistent cause and the distribution of disease affecting factors, and put forward a method of its solutions. To collect 240 positive and negative typing-discordant blood speciments from patients examined by Gel card and send these speciments to blood type reference laboratory for examining with the classic tube method and serological test, such as salivary blood-group substance, in order to performe genotyping method when serologic test can not be determined. Among 240 positive and negative typing-discordant blood speciments from patients examined by Gel card, 107 blood speciments were positive and negative consistent examined by false agglutination test (44.58%), 133 blood specinents were discordent examined by false agglutination (55.42%), out of them, 35 cases (14.58%) with inconsistent cold agglutination test, 22 cases (9.17%) with weakened AB antigenicity, 16 cases (6.67%) with ABO subtyping, 12 cases (5.00%) with positive direct antiglobulin test, 11 cases (4.58%) with reduced or without antibodies, 11 cases (4.58%) with false aggregation caused by drugs or protein, 11 cases (4.58%) with salivary blood-type substances, 8 cases (3.33%) with non-ABO alloantibody, and 7 cases (2.92%) with allogeneic bone marrow transplantation. The distribution of disease were following: blood disease (16.83%), tumor (11.88%), and cardiopulmonary diseases (11.39%); chi-square test results indicated that the distribution significantly different. The analysis of ABO blood grouping shows a variety factors influencing positive and negative blood typing, and the Gel Card identification can produc more false positive blood types. Therefore, more attention should be paid on the high incidence diseases, such as blood disease, tumor, and cardiopulmonary disease.
Cao, Xia; Xie, Xiumei; Xu, Guo; Yuan, Hong; Chen, Zhiheng
2014-06-01
To investigate the relationship between high-normal blood pressure and chronic kidney disease (CKD) in occupational physical examination population in Changsha. With a convenient sampling method, a cross-sectional survey of representative sample of 11 274 white collar workers was conducted in Changsha between March 2011 and May 2011 in a large comprehensive hospital. All subjects were assigned into 4 groups: a normal blood pressure group, a high-normal blood pressure group, an undiagnosed hypertension group, and a diagnosed hypertension group. Anthropometry, blood pressure, blood sample and urine sample were measured with standard instruments and methodology for all the subjects. Multiple logistic regression analysis was used to identify risk factors for CKD. The prevalence of CKD in the normal blood pressure, high-normal blood pressure, undiagnosed hypertension, and diagnosed hypertension were 3.31%, 6.60%, 11.78%, and 17.35%, respectively. The prevalence of CKD in males was significantly higher than that in females (P<0.01). For males with high-normal blood pressure, the CKD risk was significantly greater (OR, 1.30; 95% CI:1.03 - 1.63) than those with optimal blood pressure. The logistic regression analysis showed that there was an additive effect of hyperuricemia on CKD risk in men with high-normal blood pressure compared with men with optimal blood pressure (OR, 2.25; 95% CI, 1.59 - 3.19; P<0.05). The prevalence of CKD in people with the high-normal blood pressure is 6.60% in occupational physical examination population in Changsha. CKD is a high risk for men with highnormal blood pressure and hyperuricemia is an independent risk factor.
Noninvasive blood pressure measurement scheme based on optical fiber sensor
NASA Astrophysics Data System (ADS)
Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan
2016-10-01
Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.
Impact of hyperthermal rotary blood pump surfaces on blood clotting behavior: an approach.
Hamilton, Kathrin F; Schlanstein, Peter C; Mager, Ilona; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2009-09-01
The influence of heat dissipating systems, such as rotary blood pumps, was investigated. Titanium cylinders as rotary blood pump housing dummies were immersed in porcine blood and constantly tempered at specific temperatures (37-60 degrees C) over a defined period of time. The porcine blood was anticoagulated either by low heparin dosage or citrate. At frequent intervals, samples were taken for blood analysis and the determination of the plasmatic coagulation cascade. Blood parameters do not alter at surface temperatures below 50 degrees C. Hyperthermia-induced hemolysis could be confirmed. The plasmatic coagulation cascade is terminated at surface temperatures exceeding 55 degrees C. The adhesion of blood constituents on surfaces is temperature and time dependent, and structural changes of adhesions and blood itself were detected.
NASA Astrophysics Data System (ADS)
Gnyba, M.; Wróbel, M. S.; Karpienko, K.; Milewska, D.; Jedrzejewska-Szczerska, M.
2015-07-01
In this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular composition. A series of in-vitro measurements were carried out to assess sufficient accuracy for monitoring of blood parameters. A vast number of blood samples with various hematological parameters, collected from different donors, were measured in order to achieve a statistical significance of results and validation of the methods. Preliminary results indicate the benefits in combination of presented complementary methods and form the basis for development of a multimodal system for rapid and accurate optical determination of selected parameters in whole human blood. Future development of optical systems and multivariate calibration models are planned to extend the number of detected blood parameters and provide a robust quantitative multi-component analysis.
NASA Astrophysics Data System (ADS)
Stotesbury, Theresa E.
The research and development of synthetic blood substitutes is a reported need within the forensic community. This work contributes to the growing body of knowledge in bloodstain pattern analysis by offering a materials science approach to designing, producing and testing synthetic forensic blood substitutes. A key deliverable from this research is the creation of a robust silicon-based material using the solution-gelation technique that has been validated for controlled passive drip and spatter simulation. The work investigates the physical properties (viscosity, surface tension and density) of forensic blood substitute formulations and describes the similarity in the spreading dynamics of the optimized material to whole human blood. It then explores how blood and other fluids behave in impact simulation using high-speed video analysis and supports the use of the optimized material for spatter simulation. Finally, the work highlights the practical value of the material as an educational tool for both basic and advanced bloodstain experimentation and training.
Blood pressure changes during pregnancy: impact of race, body mass index, and weight gain.
Magriples, Urania; Boynton, Marcella H; Kershaw, Trace S; Duffany, Kathleen O; Rising, Sharon Schindler; Ickovics, Jeannette R
2013-05-01
To investigate the effect of race, body mass index (BMI), and weight gain on blood pressure in pregnancy and postpartum. Secondary analysis of pregnant women aged 14 to 25 who received prenatal care at a university-affiliated public clinic in New Haven, Connecticut and delivered singleton term infants (n = 418). Longitudinal multivariate analysis was used to evaluate blood pressure trajectories from pregnancy through 12 weeks postpartum. Obese and overweight women had significantly higher blood pressure readings as compared with women with normal BMI (all p < 0.05). African American women who had high pregnancy weight gain had the greatest increase in mean arterial and diastolic blood pressures in pregnancy and postpartum. Blood pressure trajectories in pregnancy and postpartum are significantly affected by race, BMI, and weight gain. Given the young age of this cohort, targeted efforts must be made for postpartum weight reduction to reduce cardiovascular risk. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Peregrina-Barreto, Hayde; Perez-Corona, Elizabeth; Rangel-Magdaleno, Jose; Ramos-Garcia, Ruben; Chiu, Roger; Ramirez-San-Juan, Julio C
2017-06-01
Visualization of deep blood vessels in speckle images is an important task as it is used to analyze the dynamics of the blood flow and the health status of biological tissue. Laser speckle imaging is a wide-field optical technique to measure relative blood flow speed based on the local speckle contrast analysis. However, it has been reported that this technique is limited to certain deep blood vessels (about ? = 300 ?? ? m ) because of the high scattering of the sample; beyond this depth, the quality of the vessel’s image decreases. The use of a representation based on homogeneity values, computed from the co-occurrence matrix, is proposed as it provides an improved vessel definition and its corresponding diameter. Moreover, a methodology is proposed for automatic blood vessel location based on the kurtosis analysis. Results were obtained from the different skin phantoms, showing that it is possible to identify the vessel region for different morphologies, even up to 900 ?? ? m in depth.
Robinson, Hayley; MacDonald, Bruce; Broadbent, Elizabeth
2015-03-01
To investigate the effects of interacting with the companion robot, Paro, on blood pressure and heart rate of older people in a residential care facility. This study used a repeated measures design. Twenty-one residents in rest home and hospital level care had their blood pressure taken three times; before, during and after interacting with the seal robot. Four residents who did not interact with the robot were excluded from the final analysis (final n = 17). The final analysis found that systolic and diastolic blood pressure changed significantly over time as did heart rate. Planned comparisons revealed that systolic and diastolic blood pressure decreased significantly from baseline to when residents had Paro (systolic, P = 0.048; diastolic, P = 0.05). Diastolic blood pressure increased significantly after Paro was withdrawn (P = 0.03). Interacting with Paro has a physiological effect on cardiovascular measures, which is similar to findings with live animals. © 2013 ACOTA.
Methodology for determining major constituents of ayahuasca and their metabolites in blood.
McIlhenny, Ethan H; Riba, Jordi; Barbanoj, Manel J; Strassman, Rick; Barker, Steven A
2012-03-01
There is an increasing interest in potential medical applications of ayahuasca, a South American psychotropic plant tea with a long cultural history of indigenous medical and religious use. Clinical research into ayahuasca will require specific, sensitive and comprehensive methods for the characterization and quantitation of these compounds and their metabolites in blood. A combination of two analytical techniques (high-performance liquid chromatography with ultraviolet and/or fluorescence detection and gas chromatography with nitrogen-phosphorus detection) has been used for the analysis of some of the constituents of ayahuasca in blood following its oral consumption. We report here a single methodology for the direct analysis of 14 of the major alkaloid components of ayahuasca, including several known and potential metabolites of N,N-dimethyltryptamine and the harmala alkaloids in blood. The method uses 96-well plate/protein precipitation/filtration for plasma samples, and analysis by HPLC-ion trap-ion trap-mass spectrometry using heated electrospray ionization to reduce matrix effects. The method expands the list of compounds capable of being monitored in blood following ayahuasca administration while providing a simplified approach to their analysis. The method has adequate sensitivity, specificity and reproducibility to make it useful for clinical research with ayahuasca. Copyright © 2011 John Wiley & Sons, Ltd.
Meta sequence analysis of human blood peptides and their parent proteins.
Bowden, Peter; Pendrak, Voitek; Zhu, Peihong; Marshall, John G
2010-04-18
Sequence analysis of the blood peptides and their qualities will be key to understanding the mechanisms that contribute to error in LC-ESI-MS/MS. Analysis of peptides and their proteins at the level of sequences is much more direct and informative than the comparison of disparate accession numbers. A portable database of all blood peptide and protein sequences with descriptor fields and gene ontology terms might be useful for designing immunological or MRM assays from human blood. The results of twelve studies of human blood peptides and/or proteins identified by LC-MS/MS and correlated against a disparate array of genetic libraries were parsed and matched to proteins from the human ENSEMBL, SwissProt and RefSeq databases by SQL. The reported peptide and protein sequences were organized into an SQL database with full protein sequences and up to five unique peptides in order of prevalence along with the peptide count for each protein. Structured query language or BLAST was used to acquire descriptive information in current databases. Sampling error at the level of peptides is the largest source of disparity between groups. Chi Square analysis of peptide to protein distributions confirmed the significant agreement between groups on identified proteins. Copyright 2010. Published by Elsevier B.V.
Hyperspectral imaging and multivariate analysis in the dried blood spots investigations
NASA Astrophysics Data System (ADS)
Majda, Alicja; Wietecha-Posłuszny, Renata; Mendys, Agata; Wójtowicz, Anna; Łydżba-Kopczyńska, Barbara
2018-04-01
The aim of this study was to apply a new methodology using the combination of the hyperspectral imaging and the dry blood spot (DBS) collecting. Application of the hyperspectral imaging is fast and non-destructive. DBS method offers the advantage also on the micro-invasive blood collecting and low volume of required sample. During experimental step, the reflected light was recorded by two hyperspectral systems. The collection of 776 spectral bands in the VIS-NIR range (400-1000 nm) and 256 spectral bands in the SWIR range (970-2500 nm) was applied. Pixel has the size of 8 × 8 and 30 × 30 µm for VIS-NIR and SWIR camera, respectively. The obtained data in the form of hyperspectral cubes were treated with chemometric methods, i.e., minimum noise fraction and principal component analysis. It has been shown that the application of these methods on this type of data, by analyzing the scatter plots, allows a rapid analysis of the homogeneity of DBS, and the selection of representative areas for further analysis. It also gives the possibility of tracking the dynamics of changes occurring in biological traces applied on the surface. For the analyzed 28 blood samples, described method allowed to distinguish those blood stains because of time of apply.
Odoardi, Sara; Anzillotti, Luca; Strano-Rossi, Sabina
2014-10-01
The complexity of biological matrices, such as blood, requires the development of suitably selective and reliable sample pretreatment procedures prior to their instrumental analysis. A method has been developed for the analysis of drugs of abuse and their metabolites from different chemical classes (opiates, methadone, fentanyl and analogues, cocaine, amphetamines and amphetamine-like substances, ketamine, LSD) in human blood using dried blood spot (DBS) and subsequent UHPLC-MS/MS analysis. DBS extraction required only 100μL of sample, added with the internal standards and then three droplets (30μL each) of this solution were spotted on the card, let dry for 1h, punched and extracted with methanol with 0.1% of formic acid. The supernatant was evaporated and the residue was then reconstituted in 100μL of water with 0.1% of formic acid and injected in the UHPLC-MS/MS system. The method was validated considering the following parameters: LOD and LOQ, linearity, precision, accuracy, matrix effect and dilution integrity. LODs were 0.05-1ng/mL and LOQs were 0.2-2ng/mL. The method showed satisfactory linearity for all substances, with determination coefficients always higher than 0.99. Intra and inter day precision, accuracy, matrix effect and dilution integrity were acceptable for all the studied substances. The addition of internal standards before DBS extraction and the deposition of a fixed volume of blood on the filter cards ensured the accurate quantification of the analytes. The validated method was then applied to authentic postmortem blood samples. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Wang, Hao; Shen, Bin; Zeng, Yi
2015-11-01
There has been much debate and controversy about the safety and efficacy of the topical use of tranexamic acid in primary total knee arthroplasty (TKA). The purpose of this study was to perform a meta-analysis to evaluate whether there is less blood loss and lower rates of transfusion after topical tranexamic acid administration in primary TKA. A systematic review of the electronic databases PubMed, CENTRAL, Web of Science, and Embase was undertaken. All randomized, controlled trials and prospective cohort studies evaluating the effectiveness of topical tranexamic acid during primary TKA were included. The focus of the analysis was on the outcomes of blood loss results, transfusion rate, and thromboembolic complications. Subgroup analysis was performed when possible. Of 387 studies identified, 16 comprising 1421 patients (1481 knees) were eligible for data extraction and meta-analysis. This study indicated that when compared with the control group, topical application of tranexamic acid significantly reduced total drain output (mean difference, -227.20; 95% confidence interval, -347.11 to -107.30; P<.00001), total blood loss (mean difference, -311.28; 95% confidence interval, -404.94 to -217.62; P<.00001), maximum postoperative hemoglobin decrease (mean difference, -0.73; 95% confidence interval, -0.96 to -0.50; P<.00001), and blood transfusion requirements (risk ratios, 0.33; 95% confidence interval, 0.24 to 0.43; P=.14). The authors found a statistically significant reduction in blood loss and transfusion rates when using topical tranexamic acid in primary TKA. Furthermore, the currently available evidence does not support an increased risk of deep venous thrombosis or pulmonary embolism due to tranexamic acid administration. Topical tranexamic acid was effective for reducing postoperative blood loss and transfusion requirements without increasing the prevalence of thromboembolic complications. Copyright 2015, SLACK Incorporated.
The effect of orthostatic stress on multiscale entropy of heart rate and blood pressure.
Turianikova, Zuzana; Javorka, Kamil; Baumert, Mathias; Calkovska, Andrea; Javorka, Michal
2011-09-01
Cardiovascular control acts over multiple time scales, which introduces a significant amount of complexity to heart rate and blood pressure time series. Multiscale entropy (MSE) analysis has been developed to quantify the complexity of a time series over multiple time scales. In previous studies, MSE analyses identified impaired cardiovascular control and increased cardiovascular risk in various pathological conditions. Despite the increasing acceptance of the MSE technique in clinical research, information underpinning the involvement of the autonomic nervous system in the MSE of heart rate and blood pressure is lacking. The objective of this study is to investigate the effect of orthostatic challenge on the MSE of heart rate and blood pressure variability (HRV, BPV) and the correlation between MSE (complexity measures) and traditional linear (time and frequency domain) measures. MSE analysis of HRV and BPV was performed in 28 healthy young subjects on 1000 consecutive heart beats in the supine and standing positions. Sample entropy values were assessed on scales of 1-10. We found that MSE of heart rate and blood pressure signals is sensitive to changes in autonomic balance caused by postural change from the supine to the standing position. The effect of orthostatic challenge on heart rate and blood pressure complexity depended on the time scale under investigation. Entropy values did not correlate with the mean values of heart rate and blood pressure and showed only weak correlations with linear HRV and BPV measures. In conclusion, the MSE analysis of heart rate and blood pressure provides a sensitive tool to detect changes in autonomic balance as induced by postural change.
Tavakol, Najmeh; Kheiri, Soleiman; Sedehi, Morteza
2016-01-01
Time to donating blood plays a major role in a regular donor to becoming continues one. The aim of this study was to determine the effective factors on the interval between the blood donations. In a longitudinal study in 2008, 864 samples of first-time donors in Shahrekord Blood Transfusion Center, capital city of Chaharmahal and Bakhtiari Province, Iran were selected by a systematic sampling and were followed up for five years. Among these samples, a subset of 424 donors who had at least two successful blood donations were chosen for this study and the time intervals between their donations were measured as response variable. Sex, body weight, age, marital status, education, stay and job were recorded as independent variables. Data analysis was performed based on log-normal hazard model with gamma correlated frailty. In this model, the frailties are sum of two independent components assumed a gamma distribution. The analysis was done via Bayesian approach using Markov Chain Monte Carlo algorithm by OpenBUGS. Convergence was checked via Gelman-Rubin criteria using BOA program in R. Age, job and education were significant on chance to donate blood (P<0.05). The chances of blood donation for the higher-aged donors, clericals, workers, free job, students and educated donors were higher and in return, time intervals between their blood donations were shorter. Due to the significance effect of some variables in the log-normal correlated frailty model, it is necessary to plan educational and cultural program to encourage the people with longer inter-donation intervals to donate more frequently.
Zakaria, Rosita; Allen, Katrina J; Koplin, Jennifer J; Roche, Peter; Greaves, Ronda F
2016-12-01
Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; "blood spot" and "mass spectrometry"; while excluding "newborn"; and "neonate". In addition, databases were restricted to English language and human specific. There was no time period limit applied. As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required.
Design of photonic crystal based ring resonator for detection of different blood constituents
NASA Astrophysics Data System (ADS)
Sharma, Poonam; Sharan, Preeta
2015-08-01
In this paper a photonic crystal based ring resonator structure (PCRR) which can sense different bio-constituents in blood in the wavelength range of 1530-1565 nm for biomedical applications has been successfully demonstrated. Simulation and analysis has been done for Biotin-Streptavidin, Bovine Serum Albumin, Cytop (polymer), Ethanol, Glucose solution (40gm/100 ml), Hemoglobin, Blood Plasma, Polyacrylamide and Sylgard184. Finite Difference Time Domain (FDTD) method has been used for the analysis. MEEP (MIT Electromagnetic Equation Propagation) and MPB (MIT Photonic Bands) simulation tools have been used for modeling and designing of PCRR and IPKISS software framework has been used for generation of mask design which can be used for the fabrication of the PCRR sensor. The optical properties of different bio-constituents are studied and the normalized transmitted output power, transmission wavelength and Q factor have been observed for different blood-constituents which can be used for blood analysis.It has been observed that for little change in dielectric constant (ɛ) according to the blood-constituent taken there will be a moderate shift in the transmitted output power, transmission wavelength and quality factor and hence it acts as a sensor. This indicates that it is highly sensitive even for little change in refractive index. Our designed sensor has achieved sensitivity of 343 nm/RIU.
Agah, Elmira; Zardoui, Arshia; Saghazadeh, Amene; Ahmadi, Mona; Tafakhori, Abbas; Rezaei, Nima
2018-01-01
Identifying a reliable biomarker may accelerate diagnosis of multiple sclerosis (MS) and lead to early management of the disease. Accumulating evidence suggest that cerebrospinal fluid (CSF) and peripheral blood concentration of osteopontin (OPN) may have diagnostic and prognostic value in MS. We conducted a systematic review and meta-analysis of studies that measured peripheral blood and CSF levels of OPN in MS patients and controls to evaluate the diagnostic potential of this biomarker better. We searched PubMed, Web of Science and Scopus databases to find articles that measured OPN concentration in peripheral blood and CSF samples from MS patients up to October 19, 2016. Q statistic tests and the I2 index were applied for heterogeneity assessment. If the I2 index was less than 40%, the fixed-effects model was used for meta-analysis. Random-effects meta-analysis was chosen if the I2 value was greater than 40%. After removal of duplicates, 918 articles were identified, and 27 of them fulfilled the inclusion criteria. We included 22 eligible studies in the final meta-analysis. MS patients, in general, had considerably higher levels of OPN in their CSF and blood when compared to all types of controls (p<0.05). When the comparisons were made between different subtypes of MS patients and controls, the results pointed to significantly higher levels of OPN in CSF of MS subgroups (p<0.05). All subtypes of MS patients, except CIS patients, had increased blood levels of OPN compared to controls (p<0.05). In the second set of meta-analyses, we compared the peripheral blood and CSF concentrations of OPN between MS patient subtypes. CIS patients had significantly lower levels of OPN both in their peripheral blood and CSF compared to patients with progressive subtypes of MS (p<0.05). CSF concentration of OPN was significantly higher among RRMS patients compared to the CIS patients and SPMS patients (P<0.05). Finally, patients with active MS had significantly higher OPN levels in their CSF compared to patients with stable disease (P = 0.007). The result of this study confirms that increased levels of OPN exist in CSF and peripheral blood of MS patients and strengthens the evidence regarding the clinical utility of OPN as a promising and validated biomarker for MS.
Fukui, Michiaki; Ushigome, Emi; Tanaka, Muhei; Hamaguchi, Masahide; Tanaka, Toru; Atsuta, Haruhiko; Ohnishi, Masayoshi; Oda, Yohei; Hasegawa, Goji; Nakamura, Naoto
2013-03-01
Recent studies have suggested that not only mean blood pressure but also variability in blood pressure might be related to cardiovascular disease. The aim of this study was to investigate the association between home blood pressure variability on one occasion and markers of arterial stiffness in patients with type 2 diabetes. We investigated the relationship between the s.d. of clinic- or home-measured systolic blood pressure on one occasion and pulse wave velocity (PWV) in 332 patients with type 2 diabetes, and we evaluated whether the SD of clinic- or home-measured systolic blood pressure on one occasion was an independent determinant of PWV by multivariate linear regression analysis, after adjustment for known risk factors for arterial stiffness, including sex, age, duration of diabetes, body mass index, hemoglobin A1c, serum total cholesterol, triglycerides, smoking status, drinking alcohol, presence of antihypertensive medication, average systolic blood pressure and heart rate. Age, average morning home-measured systolic blood pressure, heart rate and PWV (r=0.259, P<0.0001) were positively correlated with the s.d. of morning home blood pressure on one occasion. Multiple regression analysis demonstrated that age, average morning home-measured systolic blood pressure (P=0.0019), heart rate and the s.d. of morning home-measured systolic blood pressure on one occasion (P=0.0159) were independently associated with PWV. In conclusion, home blood pressure variability on one occasion was correlated with PWV, independent of other known risk factors, in Japanese patients with type 2 diabetes.
Hamano, Tsuyoshi; Fujisawa, Yoshikazu; Yamasaki, Masayuki; Ito, Katsuhisa; Nabika, Toru; Shiwaku, Kuninori
2011-06-01
In recent years, few studies have quantified the effect of residential context on blood pressure. Although these studies have emphasized the importance of socioeconomic influences such as education or poverty levels, the association between the features of social structure such as social capital and blood pressure remain unclear. Therefore, we investigated whether social capital was associated with systolic blood pressure after controlling for individual potential confounders. We analyzed data from the Shimane Study conducted from 2006 to 2008 in rural mountainous regions of Japan. After excluding the missing data and data of participants taking hypertension medication, we conducted a multilevel analysis of the data for 335 individuals nested within 30 postcode sectors. Systolic blood pressure increased with increasing age and body mass index. We also found that a higher systolic blood pressure was observed among smokers and those taking medication for diabetes. Regarding the contextual effects of social capital, systolic blood pressure increased with an increasing proportion of lack of fairness, after adjustment for individual confounders. To the best of our knowledge, this study is the first to investigate the association between social capital and systolic blood pressure by using a multilevel methodological framework. Surprisingly, we found that lack of fairness had a strong effect on systolic blood pressure. However, we could not find any significant associations between other items of social capital and systolic blood pressure. Further studies are needed to clarify the mechanism by which lack of fairness may have an effect on systolic blood pressure.
Rinehart, Joseph B; Lee, Tiffany C; Kaneshiro, Kayleigh; Tran, Minh-Ha; Sun, Coral; Kain, Zeev N
2016-04-01
As part of ongoing perioperative surgical home implantation process, we applied a previously published algorithm for creation of a maximum surgical blood order schedule (MSBOS) to our operating rooms. We hypothesized that using the MSBOS we could show a reduction in unnecessary preoperative blood testing and associated costs. Data regarding all surgical cases done at UC Irvine Health's operating rooms from January 1, 2011, to January 1, 2014 were extracted from the anesthesia information management systems (AIMS). After the data were organized into surgical specialties and operative sites, blood order recommendations were generated based on five specific case characteristics of the group. Next, we assessed current ordering practices in comparison to actual blood utilization to identify potential areas of wastage and performed a cost analysis comparing the annual hospital costs from preoperative blood orders if the blood order schedule were to be followed to historical practices. Of the 19,138 patients who were categorized by the MSBOS as needing no blood sample, 2694 (14.0%) had a type and screen (T/S) ordered and 1116 (5.8%) had a type and crossmatch ordered. Of the 6073 procedures where MSBOS recommended only a T/S, 2355 (38.8%) had blood crossmatched. The cost analysis demonstrated an annual reduction in actual hospital costs of $57,335 with the MSBOS compared to historical blood ordering practices. We showed that the algorithm for development of a multispecialty blood order schedule is transferable and yielded reductions in preoperative blood product screening at our institution. © 2016 AABB.
Behavior patterns and coronary heart disease
NASA Technical Reports Server (NTRS)
Townsend, J. C.; Cronin, J. P.
1975-01-01
The relationships between two behavioral patterns, cardiac risk factors, and coronary heart disease are investigated. Risk factors used in the analysis were family history of coronary disease, smoking, cholesterol, obesity, systotic blood pressure, diastolic blood pressure, blood sugar, uric acid, erythrocyte sedimentation rate, and white blood unit. It was found that conventional, non-behavioral pattern risk factors alone were not significantly related to coronary heart disease.
Reinhart, Kurt M; Coleman, Craig I; Teevan, Colleen; Vachhani, Payal; White, C Michael
2008-12-01
Garlic has been suggested to lower blood pressure; however, studies evaluating this parameter have provided conflicting results. To examine the effect of garlic on blood pressure in patients with and without elevated systolic blood pressure (SPB) through meta-analyses of randomized controlled trials. A systematic search of MEDLINE, CINAHL, and the Cochrane Central Register of Controlled Trials was conducted to identify randomized controlled trials in humans evaluating garlic's effect on blood pressure. All databases were searched from their inception through June 26, 2008, using the key words garlic, Allium sativum, and allicin. A manual search of published literature was used to identify additional relevant studies. To be included in the analysis, studies must have been written in English or German and reported endpoints of SBP or diastolic blood pressure (DBP). Studies whose population had a mean baseline SBP greater than 140 mm Hg were evaluated separately from those whose population had lower baseline blood pressures. Garlic's effect on SBP and DBP was treated as a continuous variable and weighted mean differences were calculated using a random-effects model. Ten trials were included in the analysis; 3 of these had patients with elevated SBP. Garlic reduced SBP by 16.3 mm Hg (95% CI 6.2 to 26.5) and DBP by 9.3 mm Hg (95% CI 5.3 to 13.3) compared with placebo in patients with elevated SBP. However, the use of garlic did not reduce SBP or DBP in patients without elevated SBP. There was only a minor degree of heterogeneity in the analyses and publication bias did not appear to influence the results. This meta-analysis suggests that garlic is associated with blood pressure reductions in patients with an elevated SBP although not in those without elevated SBP. Future research should focus on the impact of garlic on clinical events and the assessment of the long-term risk of harm.
Low-level lead exposure and children's IQ: A meta-analysis and search for a threshold
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schwartz, J.
1994-04-01
To assess the strength of the association between blood lead and children's IQ, a meta-analysis of the studies examining the relationship in school age children was performed. Emphasis was given to the size of the effect, since that allow comparisons that are informative about potential confounding and effect modifiers. Sensitivity analyses were also performed. A highly significant association was found between lead exposure and children's IQ (P < 0.001). An increase in blood lead from 10 to 20 [mu]g/dl was associated with a decrease of 2.6 IQ points in the meta-analysis. This result was robust to inclusion or exclusion ofmore » the strongest individual studies and to relaxing the age requirements (school age children) of the meta-analysis. Adding eight studies with effect estimates of O would still leave a significant association with blood lead (P < 0.01). There was no evidence that the effect was limited to disadvantaged children and there was a suggestion of the opposite. The studies with mean blood lead levels of 15 [mu]g/dl or lower in their sample had higher estimated blood lead slopes, suggesting that a threshold at 10 [mu]g/dl is implausible. The study with the lowest mean blood lead level was examined using nonparametric smoothing. It showed no evidence of a threshold down to blood lead concentrations of 1 [mu]g/dl. Lead interferes with GABAergic and dopaminergic neurotransmission. It has been shown to bind to the NMDA receptor and inhibit long-term potentiation in the hippocampal region of the brain. Moreover, experimental studies have demonstrated that blood levels of 10 [mu]g/dl interfere with a broad range of cognitive function in primates. Given this support, these associations in humans should be considered causal. 32 refs., 4 figs., 1 tab.« less
Whole-Genome Saliva and Blood DNA Methylation Profiling in Individuals with a Respiratory Allergy
Declerck, Ken; Traen, Sophie; Koppen, Gudrun; Van Camp, Guy; Schoeters, Greet; Vanden Berghe, Wim; De Boever, Patrick
2016-01-01
The etiology of respiratory allergies (RA) can be partly explained by DNA methylation changes caused by adverse environmental and lifestyle factors experienced early in life. Longitudinal, prospective studies can aid in the unravelment of the epigenetic mechanisms involved in the disease development. High compliance rates can be expected in these studies when data is collected using non-invasive and convenient procedures. Saliva is an attractive biofluid to analyze changes in DNA methylation patterns. We investigated in a pilot study the differential methylation in saliva of RA (n = 5) compared to healthy controls (n = 5) using the Illumina Methylation 450K BeadChip platform. We evaluated the results against the results obtained in mononuclear blood cells from the same individuals. Differences in methylation patterns from saliva and mononuclear blood cells were clearly distinguishable (PAdj<0.001 and |Δβ|>0.2), though the methylation status of about 96% of the cg-sites was comparable between peripheral blood mononuclear cells and saliva. When comparing RA cases with healthy controls, the number of differentially methylated sites (DMS) in saliva and blood were 485 and 437 (P<0.05 and |Δβ|>0.1), respectively, of which 216 were in common. The methylation levels of these sites were significantly correlated between blood and saliva. The absolute levels of methylation in blood and saliva were confirmed for 3 selected DMS in the PM20D1, STK32C, and FGFR2 genes using pyrosequencing analysis. The differential methylation could only be confirmed for DMS in PM20D1 and STK32C genes in saliva. We show that saliva can be used for genome-wide methylation analysis and that it is possible to identify DMS when comparing RA cases and healthy controls. The results were replicated in blood cells of the same individuals and confirmed by pyrosequencing analysis. This study provides proof-of-concept for the applicability of saliva-based whole-genome methylation analysis in the field of respiratory allergy. PMID:26999364
Monitoring the condition of the fetus during delivery.
Sarvilinna, Nanna; Isaksson, Camilla; Kokljuschkin, Henrica; Timonen, Susanna; Halmesmäki, Erja
Uterine contractions during delivery increase the resistance to flow in the blood vessels of the placenta and decreases placental blood circulation, possibly subjecting the fetus to hypoxia. Several methods have been developed for monitoring the condition of the fetus during delivery. Cardiotocography is used to monitor the fetus's heart rate and variability in relation to the mother's contractions. A change in cardiotocography recording due to stimulation of the presenting part is an indication of a healthy fetus. ST analysis of fetal ECG depicts the oxygenation of fetal cardiac muscle during delivery. In addition to cardiotocography and ST analysis, analysis of blood gases and lactate determination are used in assessing the condition of the fetus.
Kotnik, Petra; Krajnc, Metka Koren; Pahor, Artur; Finšgar, Matjaž; Knez, Željko
2018-02-20
A quantitative analysis of zinc endopeptidases matrix metalloproteinase 9 (MMP9) and matrix metalloproteinase 3 (MMP3) from human blood serum are presented. Both matrix metalloproteinases (MMP) are present in human blood serum and can be used as biomarkers for different diseases. The analysis was performed using LC-MS/MS with a triple quadrupole mass spectrometer, based on two specific peptides of each MMP in comparison with an enzyme-linked immunosorbent assay (ELISA). While the conditions for the LC-MS/MS analysis of MMP9 peptides were previously reported for bronchoalveolar lavage fluid, the analysis of MMP3 peptides was newly quantified for human blood serum herein for the first time. For MMP3, the linear behaviour was determined in the concentration range from 1.0-200.0ng/mL (R 2 =0.997) with an LLOD of 0.5ng/mL. For MMP9, linearity was determined in the concentration range from 6.5-65.0ng/mL (R 2 =0.995) with an LLOD of 2.0ng/mL. Copyright © 2017 Elsevier B.V. All rights reserved.
A system for automatic analysis of blood pressure data for digital computer entry
NASA Technical Reports Server (NTRS)
Miller, R. L.
1972-01-01
Operation of automatic blood pressure data system is described. Analog blood pressure signal is analyzed by three separate circuits, systolic, diastolic, and cycle defect. Digital computer output is displayed on teletype paper tape punch and video screen. Illustration of system is included.
Vongsakulyanon, A; Kitpoka, P; Kunakorn, M; Srikhirin, T
2015-12-01
To develop reliable and convenient methods for Miltenberger (Mi(a) ) blood group typing. To apply real-time polymerase chain reaction (qPCR) melting curve analysis to Mi(a) blood group typing. The Mi(a) blood group is the collective set of glycophorin hybrids in the MNS blood group system. Mi(a+) blood is common among East Asians and is also found in the Thai population. Incompatible Mi(a) blood transfusions pose the risk of life-threatening haemolysis; therefore, Mi(a) blood group typing is necessary in ethnicities where the Mi(a) blood group is prevalent. One hundred and forty-three blood samples from Thai blood donors were used in the study. The samples included 50 Mi(a+) samples and 93 Mi(a-) samples, which were defined by serology. The samples were typed by Mi(a) typing qPCR, and 50 Mi(a+) samples were sequenced to identify the Mi(a) subtypes. Mi(a) subtyping qPCR was performed to define GP.Mur. Both Mi(a) typing and Mi(a) subtyping were tested on a conventional PCR platform. The results of Mi(a) typing qPCR were all concordant with serology. Sequencing of the 50 Mi(a+) samples revealed 47 GP.Mur samples and 3 GP.Hop or Bun samples. Mi(a) subtyping qPCR was the supplementary test used to further define GP.Mur from other Mi(a) subtypes. Both Mi(a) typing and Mi(a) subtyping performed well using a conventional PCR platform. Mi(a) typing qPCR correctly identified Mi(a) blood groups in a Thai population with the feasibility of Mi(a) subtype discrimination, and Mi(a) subtyping qPCR was able to further define GP.Mur from other Mi(a) subtypes. © 2015 British Blood Transfusion Society.
Influence of ABO blood group on sports performance.
Lippi, Giuseppe; Gandini, Giorgio; Salvagno, Gian Luca; Skafidas, Spyros; Festa, Luca; Danese, Elisa; Montagnana, Martina; Sanchis-Gomar, Fabian; Tarperi, Cantor; Schena, Federico
2017-06-01
Despite being a recessive trait, the O blood group is the most frequent worldwide among the ABO blood types. Since running performance has been recognized as a major driver of evolutionary advantage in humans, we planned a study to investigate whether the ABO blood group may have an influence on endurance running performance in middle-aged recreational athletes. The study population consisted of 52 recreational, middle-aged, Caucasian athletes (mean age: 49±13 years, body mass index, 23.4±2.3 kg/m 2 ), regularly engaged in endurance activity. The athletes participated to a scientific event called "Run for Science" (R4S), entailing the completion of a 21.1 km (half-marathon) run under competing conditions. The ABO blood type status of the participants was provided by the local Service of Transfusion Medicine. In univariate analysis, running performance was significantly associated with age and weekly training, but not with body mass index. In multiple linear regression analysis, age and weekly training remained significantly associated with running performance. The ABO blood group status was also found to be independently associated with running time, with O blood type athletes performing better than those with non-O blood groups. Overall, age, weekly training and O blood group type explained 62.2% of the total variance of running performance (age, 41.6%; training regimen, 10.5%; ABO blood group, 10.1%). The results of our study show that recreational athletes with O blood group have better endurance performance compared to those with non-O blood group types. This finding may provide additional support to the putative evolutionary advantages of carrying the O blood group.
Buoro, Sabrina; Vavassori, Mauro; Pipitone, Silvia; Benegiamo, Anna; Lochis, Eleonora; Fumagalli, Sabina; Falanga, Anna; Marchetti, Marina; Crippa, Alberto; Ottomano, Cosimo; Lippi, Giuseppe
2015-10-01
Current haematology analysers have variable sensitivity and accuracy for counting nucleated red blood cells in samples with low values and in all those conditions characterised by altered sensitivity of red blood cells to the lysing process, such as in beta-thalassaemia or sickle-cell diseases and in neonates. The aim of our study was to evaluate the performance of the automated analyser XE-2100 at counting nucleated red blood cells in the above-mentioned three categories of subjects with potentially altered red blood cell lysis sensitivity and yet a need for accurate nucleated red blood cell counts. We measured nucleated red blood cell count by XE-2100 in peripheral blood samples of 187 subjects comprising 55 patients with beta-thalassaemia (40 major and 15 traits), 26 sickle-cell patients, 56 neonates and 50 normal subject. Results were compared with those obtained by optical microscopy. Agreement between average values of the two methods was estimated by means of Pearson's correlation and bias analysis, whereas diagnostic accuracy was estimated by analysis of receiver operating characteristic curves. The comparison between the two methods showed a Pearson's correlation of 0.99 (95% CI; 0.98-0.99; p<0.001) and bias of -0.61 (95% CI, -1.5-0.3). The area under the curve of the nucleated red blood cell count in all samples was 0.98 (95% CI, 0.96-1.00; p<0.001). Sub-analysis revealed an area under curve of 0.99 (95% CI, 0.98-1.00; p<0.001) for patients with thalassaemia, 0.94 (95% CI, 0.85-1.00; p<0.001) for patients with sickle cell anaemia, and 1.00 (95% CI, 1.0-1.0) for neonates. XE-2100 has excellent performance for nucleated red blood cell counting, especially in critical populations such as patients with haemoglobinopathies and neonates.
Echenique-Rivera, Hebert; Muzzi, Alessandro; Del Tordello, Elena; Seib, Kate L; Francois, Patrice; Rappuoli, Rino; Pizza, Mariagrazia; Serruto, Davide
2011-05-01
During infection Neisseria meningitidis (Nm) encounters multiple environments within the host, which makes rapid adaptation a crucial factor for meningococcal survival. Despite the importance of invasion into the bloodstream in the meningococcal disease process, little is known about how Nm adapts to permit survival and growth in blood. To address this, we performed a time-course transcriptome analysis using an ex vivo model of human whole blood infection. We observed that Nm alters the expression of ≈30% of ORFs of the genome and major dynamic changes were observed in the expression of transcriptional regulators, transport and binding proteins, energy metabolism, and surface-exposed virulence factors. In particular, we found that the gene encoding the regulator Fur, as well as all genes encoding iron uptake systems, were significantly up-regulated. Analysis of regulated genes encoding for surface-exposed proteins involved in Nm pathogenesis allowed us to better understand mechanisms used to circumvent host defenses. During blood infection, Nm activates genes encoding for the factor H binding proteins, fHbp and NspA, genes encoding for detoxifying enzymes such as SodC, Kat and AniA, as well as several less characterized surface-exposed proteins that might have a role in blood survival. Through mutagenesis studies of a subset of up-regulated genes we were able to identify new proteins important for survival in human blood and also to identify additional roles of previously known virulence factors in aiding survival in blood. Nm mutant strains lacking the genes encoding the hypothetical protein NMB1483 and the surface-exposed proteins NalP, Mip and NspA, the Fur regulator, the transferrin binding protein TbpB, and the L-lactate permease LctP were sensitive to killing by human blood. This increased knowledge of how Nm responds to adaptation in blood could also be helpful to develop diagnostic and therapeutic strategies to control the devastating disease cause by this microorganism.
Del Tordello, Elena; Seib, Kate L.; Francois, Patrice; Rappuoli, Rino; Pizza, Mariagrazia; Serruto, Davide
2011-01-01
During infection Neisseria meningitidis (Nm) encounters multiple environments within the host, which makes rapid adaptation a crucial factor for meningococcal survival. Despite the importance of invasion into the bloodstream in the meningococcal disease process, little is known about how Nm adapts to permit survival and growth in blood. To address this, we performed a time-course transcriptome analysis using an ex vivo model of human whole blood infection. We observed that Nm alters the expression of ≈30% of ORFs of the genome and major dynamic changes were observed in the expression of transcriptional regulators, transport and binding proteins, energy metabolism, and surface-exposed virulence factors. In particular, we found that the gene encoding the regulator Fur, as well as all genes encoding iron uptake systems, were significantly up-regulated. Analysis of regulated genes encoding for surface-exposed proteins involved in Nm pathogenesis allowed us to better understand mechanisms used to circumvent host defenses. During blood infection, Nm activates genes encoding for the factor H binding proteins, fHbp and NspA, genes encoding for detoxifying enzymes such as SodC, Kat and AniA, as well as several less characterized surface-exposed proteins that might have a role in blood survival. Through mutagenesis studies of a subset of up-regulated genes we were able to identify new proteins important for survival in human blood and also to identify additional roles of previously known virulence factors in aiding survival in blood. Nm mutant strains lacking the genes encoding the hypothetical protein NMB1483 and the surface-exposed proteins NalP, Mip and NspA, the Fur regulator, the transferrin binding protein TbpB, and the L-lactate permease LctP were sensitive to killing by human blood. This increased knowledge of how Nm responds to adaptation in blood could also be helpful to develop diagnostic and therapeutic strategies to control the devastating disease cause by this microorganism. PMID:21589640
NASA Astrophysics Data System (ADS)
Rocha-Osornio, L. N.; Pichardo-Molina, J. L.; Barbosa-Garcia, O.; Frausto-Reyes, C.; Araujo-Andrade, C.; Huerta-Franco, R.; Gutiérrez-Juárez, G.
2008-02-01
Raman spectroscopy and Multivariate methods were used to study serum blood samples of control and breast cancer patients. Blood samples were obtained from 11 patients and 12 controls from the central region of Mexico. Our results show that principal component analysis is able to discriminate serum sample of breast cancer patients from those of control group, also the loading vectors of PCA plotted as a function of Raman shift shown which bands permitted to make the maximum discrimination between both groups of samples.
A novel wearable device for continuous, non-invasion blood pressure measurement.
Xin, Qin; Wu, Jianping
2017-08-01
In this paper, we have developed a wearable cuffless device for daily blood pressure (BP) measurement. We incorporated the light based sensor and other hard wares in a small volume for BP detection. With optimized algorithm, the real-time BP reading could be achieved, the data could be presented in the screen and be transmitted by internet of things (IoT) for history data comparison and multi-terminal viewing. Thus, further analysis provides the probability for diet or sports suggestion and alarm. We have measured BP from more than 60 subjects, compare to traditional mercury blood pressure meter, no obvious error in both systolic blood pressure (SBP) and diastolic blood pressure (DBP) are detected. Such device can be used for continues non-invasion BP detection, and further data docking and health analysis could be achieved. Copyright © 2017. Published by Elsevier Ltd.
NASA Astrophysics Data System (ADS)
Medvedeva, Maria F.; Doubrovski, Valery A.
2017-03-01
The resolution of the acousto-optical method for blood typing was estimated experimentally by means of two types of reagents: monoclonal antibodies and standard hemagglutinating sera. The peculiarity of this work is the application of digital photo images processing by pixel analysis previously proposed by the authors. The influence of the concentrations of reagents, of blood sample, which is to be tested, as well as of the duration of the ultrasonic action on the biological object upon the resolution of acousto-optical method were investigated. The optimal experimental conditions to obtain maximum of the resolution of the acousto-optical method were found, it creates the prerequisites for a reliable blood typing. The present paper is a further step in the development of acousto-optical method for determining human blood groups.
Melanin and blood concentration in human skin studied by multiple regression analysis: experiments
NASA Astrophysics Data System (ADS)
Shimada, M.; Yamada, Y.; Itoh, M.; Yatagai, T.
2001-09-01
Knowledge of the mechanism of human skin colour and measurement of melanin and blood concentration in human skin are needed in the medical and cosmetic fields. The absorbance spectrum from reflectance at the visible wavelength of human skin increases under several conditions such as a sunburn or scalding. The change of the absorbance spectrum from reflectance including the scattering effect does not correspond to the molar absorption spectrum of melanin and blood. The modified Beer-Lambert law is applied to the change in the absorbance spectrum from reflectance of human skin as the change in melanin and blood is assumed to be small. The concentration of melanin and blood was estimated from the absorbance spectrum reflectance of human skin using multiple regression analysis. Estimated concentrations were compared with the measured one in a phantom experiment and this method was applied to in vivo skin.
Vergnon, P; Colin, C; Jullien, A M; Bory, E; Excoffier, S; Matillon, Y; Trepo, C
1996-01-01
The aim of this study was to evaluate the cost of hepatitis C and non-A non-B non-C screening strategy in donated blood, currently used in French transfusion centres and to assess the effect in the blood transfusion centres according to the prevalence of the disease and the intrinsec values of tests. This screening strategy was based on alanine aminotransferase assay, and HBc and HCV antibodies detection. In 1993, a survey was conducted in 26 French transfusion centers to estimate the costs of the screening strategy currently used. Average expenditure on diagnostic sets, equipment, staff and administration charges for hepatitis C and non-A non-B non-C screening were calculated. From these results, we estimated the cost of the previous strategy which did not involve HCV antibody testing, so as to determine the incremental cost between the two strategies. We used clinical decision analysis and sensitivity analysis to estimate the incremental cost-effectiveness ratio with data gathered from the literature and examine the impact on blood transfusion centre. Implemented for 100,000 volunteer blood donations, the incremental cost of the new strategy was FF 2,566,111 (1992) and the marginal effectiveness was 180 additional infected donations detected. The sensitivity analysis showed the major influence of infection prevalence in donated blood on the incremental cost-effectiveness ratio: the lower the prevalence, the higher the cost-effectiveness ratio per contaminated blood product avoided.
Analysis of the stability of urea in dried blood spots collected and stored on filter paper.
Quraishi, Rizwana; Lakshmy, Ramakrishnan; Mukhopadhyay, Ashok Kumar; Jailkhani, Bansi Lal
2013-05-01
The ability to use dry blood spots (DBSs) on filter paper for the analysis of urea levels could be an important diagnostic tool for areas that have limited access to laboratory facilities. We developed a method for the extraction and quantification of urea from DBSs that were stored on 3M Whatman filter paper and investigated the effect of long-term storage on the level of urea in DBSs. DBSs of 4.5 mm in diameter were used for our assay, and we determined the urea levels in blood using a commercially available enzymatic kit (UV GLDH-method; Randox laboratories Ltd., UK). The DBSs on filter discs were stored at 4℃ or at 37℃ for 120 days. The mean intra- and inter-assay coefficient of variance for our method of urea extraction from dried blood was 4.2% and 6.3%, respectively. We collected 75 fresh blood samples and compared the urea content of each fresh sample with the urea content of DBSs taken from corresponding fresh blood samples. Regression analysis reported a regression coefficient (r) value of 0.97 and a recovery of urea from dried spots was 102.2%. Urea concentrations in DBSs were stable for up to 120 and 90 days when stored at 4℃ and 37℃, respectively. Our results show that urea can be stored and quantitatively recovered from small volumes of blood that was collected on filter paper.
The study of dynamic response to acute hemorrhage by pulse spectrum analysis.
Chang, Yu Hsin; Tsai, Chia I; Lin, Jaung Geng; Lin, Yue Der; Li, Tsai Chung; Su, Yi Chang
2006-01-01
Traditional Chinese Medicine (TCM) holds that blood and qi are fundamental substances in the human body for sustaining normal vital activity. The theory of qi, blood and zang-fu contribute the most important theoretical basis of human physiology in TCM. An animal model using conscious rats was employed in this study to further comprehend how organisms survive during acute hemorrhage by maintaining the functionalities of qi and blood through dynamically regulating visceral physiological conditions. Pulse waves of arterial blood pressure before and after the hemorrhage were taken in parallel to pulse spectrum analysis. Percentage differences of mean arterial blood pressure and harmonics were recorded in subsequent 5-minute intervals following the hemorrhage. Data were analyzed using a one-way analysis of variance (ANOVA) with Duncan's test for pairwise comparisons. Results showed that, within 30 minutes following the onset of acute hemorrhage,the reduction of mean arterial blood pressure was improved from 62% to 20%. Throughout the process, changes to the pulse spectrum appeared to result in a new balance over time. The percentage differences of the second and third harmonics, which were related to kidney and spleen, both increased significantly than baseline and towards another steady state. Apart from the steady state resulting from the previous stage, the percentage difference of the 4th harmonic decreased significantly to another steady state. The observed change could be attributed to the induction of functional qi, and is a result of qi-blood balancing activity that organisms hold to survive against acute bleeding.
Kassakian, Steven Z; Yackel, Thomas R; Deloughery, Thomas; Dorr, David A
2016-06-01
Red blood cell transfusion is the most common procedure in hospitalized patients in the US. Growing evidence suggests that a sizeable percentage of these transfusions are inappropriate, putting patients at significant risk and increasing costs to the health care system. We performed a retrospective quasi-experimental study from November 2008 until November 2014 in a 576-bed tertiary care hospital. The intervention consisted of an interruptive clinical decision support alert shown to a provider when a red blood cell transfusion was ordered in a patient whose most recent hematocrit was ≥21%. We used interrupted time series analysis to determine whether our primary outcome of interest, rate of red blood cell transfusion in patients with hematocrit ≥21% per 100 patient (pt) days, was reduced by the implementation of the clinical decision support tool. The rate of platelet transfusions was used as a nonequivalent dependent control variable. A total of 143,000 hospital admissions were included in our analysis. Red blood cell transfusions decreased from 9.4 to 7.8 per 100 pt days after the clinical decision support intervention was implemented. Interrupted time series analysis showed that significant decline of 0.05 (95% confidence interval [CI], 0.03-0.07; P < .001) units of red blood cells transfused per 100 pt days per month was already underway in the preintervention period. This trend accelerated to 0.1 (95% CI, 0.09-0.12; P < .001) units of red blood cells transfused per 100 pt days per month following the implementation of the clinical decision support tool. There was no statistical change in the rate of platelet transfusion resulting from the intervention. The implementation of an evidence-based clinical decision support tool was associated with a significant decline in the overuse of red blood cell transfusion. We believe this intervention could be easily replicated in other hospitals using commercial electronic health records and a similar reduction in overuse of red blood cell transfusions achieved. Copyright © 2016 Elsevier Inc. All rights reserved.
The Influence of Declining Air Lead Levels on Blood Lead-Air Lead Slope Factors in Children
This presentation describes calculation of blood lead-air lead slope factor within an analysis of the relationship between blood lead levels and air lead levels among participants in the National Health and Nutrition Examination Survey (NHANES). The slope factors are compared wi...
Image-based red cell counting for wild animals blood.
Mauricio, Claudio R M; Schneider, Fabio K; Dos Santos, Leonilda Correia
2010-01-01
An image-based red blood cell (RBC) automatic counting system is presented for wild animals blood analysis. Images with 2048×1536-pixel resolution acquired on an optical microscope using Neubauer chambers are used to evaluate RBC counting for three animal species (Leopardus pardalis, Cebus apella and Nasua nasua) and the error found using the proposed method is similar to that obtained for inter observer visual counting method, i.e., around 10%. Smaller errors (e.g., 3%) can be obtained in regions with less grid artifacts. These promising results allow the use of the proposed method either as a complete automatic counting tool in laboratories for wild animal's blood analysis or as a first counting stage in a semi-automatic counting tool.
Tu, Yu-Kang; Davey Smith, George; Gilthorpe, Mark S.
2011-01-01
Due to a problem of identification, how to estimate the distinct effects of age, time period and cohort has been a controversial issue in the analysis of trends in health outcomes in epidemiology. In this study, we propose a novel approach, partial least squares (PLS) analysis, to separate the effects of age, period, and cohort. Our example for illustration is taken from the Glasgow Alumni cohort. A total of 15,322 students (11,755 men and 3,567 women) received medical screening at the Glasgow University between 1948 and 1968. The aim is to investigate the secular trends in blood pressure over 1925 and 1950 while taking into account the year of examination and age at examination. We excluded students born before 1925 or aged over 25 years at examination and those with missing values in confounders from the analyses, resulting in 12,546 and 12,516 students for analysis of systolic and diastolic blood pressure, respectively. PLS analysis shows that both systolic and diastolic blood pressure increased with students' age, and students born later had on average lower blood pressure (SBP: −0.17 mmHg/per year [95% confidence intervals: −0.19 to −0.15] for men and −0.25 [−0.28 to −0.22] for women; DBP: −0.14 [−0.15 to −0.13] for men; −0.09 [−0.11 to −0.07] for women). PLS also shows a decreasing trend in blood pressure over the examination period. As identification is not a problem for PLS, it provides a flexible modelling strategy for age-period-cohort analysis. More emphasis is then required to clarify the substantive and conceptual issues surrounding the definitions and interpretations of age, period and cohort effects. PMID:21556329
van Beekhuizen, Heleen J; Tarimo, Vincent; Pembe, Andrea B; Fauteck, Heiner; Lotgering, Fred K
2013-09-01
To evaluate the efficacy and safety of misoprostol among patients with retained placenta in a low-resource setting. A prospective, multicenter, randomized, double-blind, placebo-controlled trial was carried out in Tanzania between April 2008 and November 2011. It included patients who delivered at a gestational age of 28 weeks or more and had blood loss of 750 mL or less at 30 minutes after delivery. Sublingual misoprostol (800 μg) was compared with placebo as the primary treatment. Power analysis showed that 117 patients would be required to observe a reduction of 40% in the incidence of manual removal of the placenta (MRP; P=0.05, 80% power), the primary outcome. The secondary outcomes were blood loss and number of blood transfusions. Interim analysis after recruitment of 95 patients showed that incidence of MRP, total blood loss, and incidence of blood transfusions were similar in the misoprostol (MRP, 40%; blood loss, 803 mL; blood transfusion, 15%) and placebo (MRP, 33%, blood loss 787 mL, blood transfusion, 23%) groups. The trial was stopped because continuation would not alter the interim conclusion that misoprostol was ineffective. Treatment with misoprostol was found to have no clinically significant beneficial effect among women with retained placenta. Current Controlled Trials ISRCTN16104753. Copyright © 2013 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
MacLachlan, N J; Nunamaker, R A; Katz, J B; Sawyer, M M; Akita, G Y; Osburn, B I; Tabachnick, W J
1994-01-01
The interval after infection when bluetongue virus (BTV) was present in the blood of calves inoculated with BTV serotype 10 (BTV 10) was evaluated by virus isolation (VI) in embryonated chicken eggs (ECE), BTV-specific polymerase chain reaction (PCR), and in vitro blood feeding of vector Culicoides variipennis (C.v.) sonorensis. BTV nucleic acid was detected by PCR in blood cells for 16 to 20 weeks after infection whereas infectious virus was detected by VI in ECE for 2 to 8 weeks. BTV was detected in calf blood by in vitro feeding of C.v. sonorensis for only 0 to 2 weeks after inoculation of calves with BTV 10. Selected bloods which were positive by PCR analysis but not by VI in ECE were not infectious for sheep. The data are consistent with the hypothesis that prolonged viremia in BTV-infected cattle results from association of the virus with blood cells, especially erythrocytes. The fact that calf blood that contained viral nucleic acid as determined by PCR analysis, but not infectious virus as determined by VI in ECE, was not infectious for either the insect vector or sheep suggests that cattle whose blood contains BTV nucleic acid but not infectious virus are unimportant to the epidemiology of BTV infection.
Blood Lead Toxicity Analysis of Multipurpose Canines and Military Working Dogs.
Reid, Paul; George, Clinton; Byrd, Christopher M; Miller, Laura; Lee, Stephen J; Motsinger-Reif, Alison; Breen, Matthew; Hayduk, Daniel W
Special Operations Forces and their accompanying tactical multipurpose canines (MPCs) who are involved in repeated live-fire exercises and military operations have the potential for increased blood lead levels and toxicity due to aerosolized and environmental lead debris. Clinical lead-toxicity symptoms can mimic other medical disorders, rendering accurate diagnosis more challenging. The objective of this study was to examine baseline lead levels of MPCs exposed to indoor firing ranges compared with those of nontactical military working dogs (MWDs) with limited or no exposure to the same environment. In the second part of the study, results of a commercially available, human-blood lead testing system were compared with those of a benchtop inductively coupled plasma-mass spectrometry (ICP-MS) analysis technique. Blood samples from 18 MPCs were tested during routine clinical blood draws, and six samples from a canine group with limited exposure to environmental lead (nontactical MWDs) were tested for comparison. There was a high correlation between results of the commercial blood-testing system compared with ICP-MS when blood lead levels were higher than 4.0µg/dL. Both testing methods recorded higher blood lead levels in the MPC blood samples than in those of the nontactical MWDs, although none of the MPC samples tested contained lead levels approaching those at which symptoms of lead toxicity have previously been reported in animals (i.e., 35µg/dL). 2018.
Quantify Glucose Level in Freshly Diabetic's Blood by Terahertz Time-Domain Spectroscopy
NASA Astrophysics Data System (ADS)
Chen, Hua; Chen, Xiaofeng; Ma, Shihua; Wu, Xiumei; Yang, Wenxing; Zhang, Weifeng; Li, Xiao
2018-04-01
We demonstrate the capability of terahertz (THz) time-domain spectroscopy (TDS) to quantify glucose level in ex vivo freshly diabetic's blood. By investigating the THz spectra of different human blood, we find out THz absorption coefficients reflect a high sensitivity to the glucose level in blood. With a quantitative analysis of 70 patients, we demonstrate that the THz absorption coefficients and the blood glucose levels perform a linear relationship. A comparative experiment between THz measurement and glucometers is also conducted with another 20 blood samples, and the results confirm that the relative error is as less as 15%. Our ex vivo human blood study indicates that THz technique has great potential application to diagnose blood glucose level in clinical practice.
Sato, Emi; Matsuda, Kouhei
2018-06-11
The purpose of this study was to examine cerebral blood flow in the frontal cortex area during personality self-rating tasks. Our two hypotheses were (1) cerebral blood flow varies based on personality rating condition and (2) cerebral blood flow varies based on the personality traits. This experiment measured cerebral blood flow under 3 personal computer rating conditions and 2 questionnaire conditions. Comparing the rating conditions, the results of the t-test indicated that cerebral blood flow was higher in the questionnaire condition than it was in the personal computer condition. With respect to the Big Five, the result of the correlation coefficient, that is, cerebral blood flow during a personality rating task, changed according to the trait for agreeableness. The results of the analysis of the 5-cluster on individual differences indicated that certain personality traits were related to the factors that increased or decreased cerebral blood flow. An analysis of variance indicated that openness to experience and Behavioural Activation System-drive was significant given that participants with high intellectual curiosity were motivated in this experiment, thus, their cerebral blood flow may have increased. The significance of this experiment was that by employing certain performance measures we could examine differences in physical changes based on personality traits. © 2018 International Union of Psychological Science.
Sakai, Yoko; Yasuo M, Tsutsumi; Oyama, Takuro; Murakami, Chiaki; Kakuta, Nami; Tanaka, Katsuya
2018-01-01
Robot-assisted laparoscopic radical prostatectomy (RALRP) is commonly performed in the surgical treatment of prostate cancer. However, the steep Trendelenburg position (25) and pneumoperitoneum required for this procedure can sometimes cause hemodynamic changes. Although blood pressure is traditionally monitored invasively during RALRP, the ClearSight system (BMEYE, Amsterdam, The Netherlands) enables a totally noninvasive and simple continuous blood pressure and cardiac output monitoring based on finger arterial pressure pulse contour analysis. We therefore investigated whether noninvasive continuous arterial blood pressure measurements using the ClearSight system were comparable to those obtained invasively in patients undergoing RALRP. Ten patients scheduled for RALRP with American Society of Anesthesiologists physical status I-II were included in this study. At each of the seven defined time points, noninvasive and invasive blood pressure measurements were documented and compared in each patient using Bland-Altman analysis. Although the blood pressure measured with the ClearSight system correlated with that measured invasively, a large difference between the values obtained by the two devices was noted. The ClearSight system was unable to detect blood pressure accurately during RALRP, suggesting that blood pressure monitoring using this device alone is not feasible in this small patient population. J. Med. Invest. 65:69-73, February, 2018.
Blood or spores? A cautionary note on interpreting cellular debris on human skeletal remains.
Cappella, A; Stefanelli, S; Caccianiga, M; Rizzi, A; Bertoglio, B; Sforza, C; Cattaneo, C
2015-07-01
The identification of red blood cells on both skeletal human remains and decomposed corpses is of remarkable importance in forensic sciences, irrespective of its diagnostic value; their presence is often perplexing and difficult to interpret especially when in the context of decomposition and taphonomical variables. Some clinical research has focused on the morphological changes of red blood cells over time by scanning electron microscopy (SEM), but no research has investigated whether botanical structures can be confused for red blood cells. Since some literature has recently presumed the detection of erythrocyte-like cells on skeletal remains (even ancient) as surely erythrocytes, and most have never taken into consideration the chance of an origin different from blood, such as botanical, the present study aims at verifying the possibility of confusion between erythrocytes and botanical cells by applying SEM analysis and at highlighting the pitfalls in this particular issue through a test submitted to pathologists and natural scientists asked to discriminate between red blood cells and different vegetal structures (60 images obtained by SEM analysis). The results showed that although there are diagnostic features useful in identifying red blood cells from botanical structures, some spores resulted very similar to decaying red blood cells, which calls for attention and great caution when studying decomposed human remains.
Diet, blood pressure, and multicollinearity.
Reed, D; McGee, D; Yano, K; Hankin, J
1985-01-01
Recent reports of an inverse association between dietary calcium intake and hypertension stimulated this analysis of the relationship of blood pressure to more than 20 dietary factors among a group of 8000 Japanese men in Hawaii. Reported intakes of potassium, calcium, protein, and milk were all inversely associated with blood pressure levels when examined one at a time while controlling for other risk factors. Alcohol intake was directly associated with blood pressure, and was treated as a confounding variable in the analysis. The association of potassium intake with blood pressure was relatively stronger than the associations for other nutrients, but the intake of potassium was so highly correlated with intakes of calcium, milk, and protein that it was not statistically possible to identify the independent association of potassium and blood pressure. Calcium intake was strongly correlated with milk and potassium intakes, and only calcium from dairy sources was associated with blood pressure. These data thus indicate that several dietary factors are inversely related to blood pressure levels independently of other risk factors such as age, body mass, and alcohol intake. The high degree of intercorrelation (multicollinearity) among these dietary factors, however, indicates that the independent role of any specific nutrient cannot be conclusively separated from the possible effects of other nutrients in this type of study.
Serious hazards of transfusion (SHOT) initiative: analysis of the first two annual reports.
Williamson, L M; Lowe, S; Love, E M; Cohen, H; Soldan, K; McClelland, D B; Skacel, P; Barbara, J A
1999-07-03
To receive and collate reports of death or major complications of transfusion of blood or components. Haematologists were invited confidentially to report deaths and major complications after blood transfusion during October 1996 to September 1998. Hospitals in United Kingdom and Ireland. Patients who died or experienced serious complications, as defined below, associated with transfusion of red cells, platelets, fresh frozen plasma, or cryoprecipitate. Death, "wrong" blood transfused to patient, acute and delayed transfusion reactions, transfusion related acute lung injury, transfusion associated graft versus host disease, post-transfusion purpura, and infection transmitted by transfusion. Circumstances relating to these cases and relative frequency of complications. Over 24 months, 366 cases were reported, of which 191 (52%) were "wrong blood to patient" episodes. Analysis of these revealed multiple errors of identification, often beginning when blood was collected from the blood bank. There were 22 deaths from all causes, including three from ABO incompatibility. There were 12 infections: four bacterial (one fatal), seven viral, and one fatal case of malaria. During the second 12 months, 164/424 hospitals (39%) submitted a "nil to report" return. Transfusion is now extremely safe, but vigilance is needed to ensure correct identification of blood and patient. Staff education should include awareness of ABO incompatibility and bacterial contamination as causes of life threatening reactions to blood.
Papanastasiou, Giorgos; Williams, Michelle C; Kershaw, Lucy E; Dweck, Marc R; Alam, Shirjel; Mirsadraee, Saeed; Connell, Martin; Gray, Calum; MacGillivray, Tom; Newby, David E; Semple, Scott Ik
2015-02-17
Mathematical modeling of cardiovascular magnetic resonance perfusion data allows absolute quantification of myocardial blood flow. Saturation of left ventricle signal during standard contrast administration can compromise the input function used when applying these models. This saturation effect is evident during application of standard Fermi models in single bolus perfusion data. Dual bolus injection protocols have been suggested to eliminate saturation but are much less practical in the clinical setting. The distributed parameter model can also be used for absolute quantification but has not been applied in patients with coronary artery disease. We assessed whether distributed parameter modeling might be less dependent on arterial input function saturation than Fermi modeling in healthy volunteers. We validated the accuracy of each model in detecting reduced myocardial blood flow in stenotic vessels versus gold-standard invasive methods. Eight healthy subjects were scanned using a dual bolus cardiac perfusion protocol at 3T. We performed both single and dual bolus analysis of these data using the distributed parameter and Fermi models. For the dual bolus analysis, a scaled pre-bolus arterial input function was used. In single bolus analysis, the arterial input function was extracted from the main bolus. We also performed analysis using both models of single bolus data obtained from five patients with coronary artery disease and findings were compared against independent invasive coronary angiography and fractional flow reserve. Statistical significance was defined as two-sided P value < 0.05. Fermi models overestimated myocardial blood flow in healthy volunteers due to arterial input function saturation in single bolus analysis compared to dual bolus analysis (P < 0.05). No difference was observed in these volunteers when applying distributed parameter-myocardial blood flow between single and dual bolus analysis. In patients, distributed parameter modeling was able to detect reduced myocardial blood flow at stress (<2.5 mL/min/mL of tissue) in all 12 stenotic vessels compared to only 9 for Fermi modeling. Comparison of single bolus versus dual bolus values suggests that distributed parameter modeling is less dependent on arterial input function saturation than Fermi modeling. Distributed parameter modeling showed excellent accuracy in detecting reduced myocardial blood flow in all stenotic vessels.
Winkelman, James W; Tanasijevic, Milenko J; Zahniser, David J
2017-08-01
- A novel automated slide-based approach to the complete blood count and white blood cell differential count is introduced. - To present proof of concept for an image-based approach to complete blood count, based on a new slide preparation technique. A preliminary data comparison with the current flow-based technology is shown. - A prototype instrument uses a proprietary method and technology to deposit a precise volume of undiluted peripheral whole blood in a monolayer onto a glass microscope slide so that every cell can be distinguished, counted, and imaged. The slide is stained, and then multispectral image analysis is used to measure the complete blood count parameters. Images from a 600-cell white blood cell differential count, as well as 5000 red blood cells and a variable number of platelets, that are present in 600 high-power fields are made available for a technologist to view on a computer screen. An initial comparison of the basic complete blood count parameters was performed, comparing 1857 specimens on both the new instrument and a flow-based hematology analyzer. - Excellent correlations were obtained between the prototype instrument and a flow-based system. The primary parameters of white blood cell, red blood cell, and platelet counts resulted in correlation coefficients (r) of 0.99, 0.99, and 0.98, respectively. Other indices included hemoglobin (r = 0.99), hematocrit (r = 0.99), mean cellular volume (r = 0.90), mean corpuscular hemoglobin (r = 0.97), and mean platelet volume (r = 0.87). For the automated white blood cell differential counts, r values were calculated for neutrophils (r = 0.98), lymphocytes (r = 0.97), monocytes (r = 0.76), eosinophils (r = 0.96), and basophils (r = 0.63). - Quantitative results for components of the complete blood count and automated white blood cell differential count can be developed by image analysis of a monolayer preparation of a known volume of peripheral blood.
Mina, Eleni; van Roon-Mom, Willeke; Hettne, Kristina; van Zwet, Erik; Goeman, Jelle; Neri, Christian; A C 't Hoen, Peter; Mons, Barend; Roos, Marco
2016-08-01
Huntington's disease (HD) is a devastating brain disorder with no effective treatment or cure available. The scarcity of brain tissue makes it hard to study changes in the brain and impossible to perform longitudinal studies. However, peripheral pathology in HD suggests that it is possible to study the disease using peripheral tissue as a monitoring tool for disease progression and/or efficacy of novel therapies. In this study, we investigated if blood can be used to monitor disease severity and progression in brain. Since previous attempts using only gene expression proved unsuccessful, we compared blood and brain Huntington's disease signatures in a functional context. Microarray HD gene expression profiles from three brain regions were compared to the transcriptome of HD blood generated by next generation sequencing. The comparison was performed with a combination of weighted gene co-expression network analysis and literature based functional analysis (Concept Profile Analysis). Uniquely, our comparison of blood and brain datasets was not based on (the very limited) gene overlap but on the similarity between the gene annotations in four different semantic categories: "biological process", "cellular component", "molecular function" and "disease or syndrome". We identified signatures in HD blood reflecting a broad pathophysiological spectrum, including alterations in the immune response, sphingolipid biosynthetic processes, lipid transport, cell signaling, protein modification, spliceosome, RNA splicing, vesicle transport, cell signaling and synaptic transmission. Part of this spectrum was reminiscent of the brain pathology. The HD signatures in caudate nucleus and BA4 exhibited the highest similarity with blood, irrespective of the category of semantic annotations used. BA9 exhibited an intermediate similarity, while cerebellum had the least similarity. We present two signatures that were shared between blood and brain: immune response and spinocerebellar ataxias. Our results demonstrate that HD blood exhibits dysregulation that is similar to brain at a functional level, but not necessarily at the level of individual genes. We report two common signatures that can be used to monitor the pathology in brain of HD patients in a non-invasive manner. Our results are an exemplar of how signals in blood data can be used to represent brain disorders. Our methodology can be used to study disease specific signatures in diseases where heterogeneous tissues are involved in the pathology.
Non-invasive pulmonary blood flow analysis and blood pressure mapping derived from 4D flow MRI
NASA Astrophysics Data System (ADS)
Delles, Michael; Rengier, Fabian; Azad, Yoo-Jin; Bodenstedt, Sebastian; von Tengg-Kobligk, Hendrik; Ley, Sebastian; Unterhinninghofen, Roland; Kauczor, Hans-Ulrich; Dillmann, Rüdiger
2015-03-01
In diagnostics and therapy control of cardiovascular diseases, detailed knowledge about the patient-specific behavior of blood flow and pressure can be essential. The only method capable of measuring complete time-resolved three-dimensional vector fields of the blood flow velocities is velocity-encoded magnetic resonance imaging (MRI), often denoted as 4D flow MRI. Furthermore, relative pressure maps can be computed from this data source, as presented by different groups in recent years. Hence, analysis of blood flow and pressure using 4D flow MRI can be a valuable technique in management of cardiovascular diseases. In order to perform these tasks, all necessary steps in the corresponding process chain can be carried out in our in-house developed software framework MEDIFRAME. In this article, we apply MEDIFRAME for a study of hemodynamics in the pulmonary arteries of five healthy volunteers. The study included measuring vector fields of blood flow velocities by phase-contrast MRI and subsequently computing relative blood pressure maps. We visualized blood flow by streamline depictions and computed characteristic values for the left and the right pulmonary artery (LPA and RPA). In all volunteers, we observed a lower amount of blood flow in the LPA compared to the RPA. Furthermore, we visualized blood pressure maps using volume rendering and generated graphs of pressure differences between the LPA, the RPA and the main pulmonary artery. In most volunteers, blood pressure was increased near to the bifurcation and in the proximal LPA, leading to higher average pressure values in the LPA compared to the RPA.
Relationship among visual field, blood flow, and neural structure measurements in glaucoma.
Hwang, John C; Konduru, Ranjith; Zhang, Xinbo; Tan, Ou; Francis, Brian A; Varma, Rohit; Sehi, Mitra; Greenfield, David S; Sadda, Srinivas R; Huang, David
2012-05-17
To determine the relationship among visual field, neural structural, and blood flow measurements in glaucoma. Case-control study. Forty-seven eyes of 42 patients with perimetric glaucoma were age-matched with 27 normal eyes of 27 patients. All patients underwent Doppler Fourier-domain optical coherence tomography to measure retinal blood flow and standard glaucoma evaluation with visual field testing and quantitative structural imaging. Linear regression analysis was performed to analyze the relationship among visual field, blood flow, and structure, after all variables were converted to logarithmic decibel scale. Retinal blood flow was reduced in glaucoma eyes compared to normal eyes (P < 0.001). Visual field loss was correlated with both reduced retinal blood flow and structural loss of rim area and retinal nerve fiber layer (RNFL). There was no correlation or paradoxical correlation between blood flow and structure. Multivariate regression analysis revealed that reduced blood flow and structural loss are independent predictors of visual field loss. Each dB decrease in blood flow was associated with at least 1.62 dB loss in mean deviation (P ≤ 0.001), whereas each dB decrease in rim area and RNFL was associated with 1.15 dB and 2.56 dB loss in mean deviation, respectively (P ≤ 0.03). There is a close link between reduced retinal blood flow and visual field loss in glaucoma that is largely independent of structural loss. Further studies are needed to elucidate the causes of the vascular dysfunction and potential avenues for therapeutic intervention. Blood flow measurement may be useful as an independent assessment of glaucoma severity.
Cardiovascular reactivity patterns and pathways to hypertension: a multivariate cluster analysis.
Brindle, R C; Ginty, A T; Jones, A; Phillips, A C; Roseboom, T J; Carroll, D; Painter, R C; de Rooij, S R
2016-12-01
Substantial evidence links exaggerated mental stress induced blood pressure reactivity to future hypertension, but the results for heart rate reactivity are less clear. For this reason multivariate cluster analysis was carried out to examine the relationship between heart rate and blood pressure reactivity patterns and hypertension in a large prospective cohort (age range 55-60 years). Four clusters emerged with statistically different systolic and diastolic blood pressure and heart rate reactivity patterns. Cluster 1 was characterised by a relatively exaggerated blood pressure and heart rate response while the blood pressure and heart rate responses of cluster 2 were relatively modest and in line with the sample mean. Cluster 3 was characterised by blunted cardiovascular stress reactivity across all variables and cluster 4, by an exaggerated blood pressure response and modest heart rate response. Membership to cluster 4 conferred an increased risk of hypertension at 5-year follow-up (hazard ratio=2.98 (95% CI: 1.50-5.90), P<0.01) that survived adjustment for a host of potential confounding variables. These results suggest that the cardiac reactivity plays a potentially important role in the link between blood pressure reactivity and hypertension and support the use of multivariate approaches to stress psychophysiology.
de Morais, Bruno Salomé; Sanches, Marcelo Dias; Ribeiro, Daniel Dias; Lima, Agnaldo Soares; de Abreu Ferrari, Teresa Cristina; Duarte, Malvina Maria de Freitas; Cançado, Guilherme Henrique Gomes Moreira
2011-01-01
Liver transplant (LT) surgery is associated with significant bleeding in 20% of cases, and several authors have demonstrated the risks related to blood components. The objective of the present study was to evaluate the impact of using blood components during hospitalization in five-year survival of patients undergoing LT. One hundred and thirteen patients were evaluated retrospectively. Several variables, including the use of blood components intraoperatively and throughout hospitalization, were categorized and evaluated by univariate analysis using Fisher's test. A level of significance of 5% was adopted. Results with p < 0.2 underwent multivariate analysis using multinomial logistic regression. Parenchymal diseases, preoperative renal dysfunction, and longer stay in hospital and ICU are associated with greater five-year mortality after LT (p < 0.05). Unlike the intraoperative use of blood components, the accumulated transfusion of packed red blood cell, frozen fresh plasma, and platelets during the entire hospitalization was associated with greater five-year mortality after liver transplantation (p < 0.01). This study emphasizes the relationship between the use of blood components during hospitalization and increased mortality in five years after LT. 2011 Elsevier Editora Ltda. All rights reserved.
Padrón-Barthe, Laura; Temiño, Susana; Villa del Campo, Cristina; Carramolino, Laura; Isern, Joan
2014-01-01
The first blood and endothelial cells of amniote embryos appear in close association in the blood islands of the yolk sac (YS). This association and in vitro lineage analyses have suggested a common origin from mesodermal precursors called hemangioblasts, specified in the primitive streak during gastrulation. Fate mapping and chimera studies, however, failed to provide strong evidence for a common origin in the early mouse YS. Additional in vitro studies suggest instead that mesodermal precursors first generate hemogenic endothelium, which then generate blood cells in a linear sequence. We conducted an in vivo clonal analysis to determine the potential of individual cells in the mouse epiblast, primitive streak, and early YS. We found that early YS blood and endothelial lineages mostly derive from independent epiblast populations, specified before gastrulation. Additionally, a subpopulation of the YS endothelium has hemogenic activity and displays characteristics similar to those found later in the embryonic hemogenic endothelium. Our results show that the earliest blood and endothelial cell populations in the mouse embryo are specified independently, and that hemogenic endothelium first appears in the YS and produces blood precursors with markers related to definitive hematopoiesis. PMID:25139355
Empirical modelling to predict the refractive index of human blood.
Yahya, M; Saghir, M Z
2016-02-21
Optical techniques used for the measurement of the optical properties of blood are of great interest in clinical diagnostics. Blood analysis is a routine procedure used in medical diagnostics to confirm a patient's condition. Measuring the optical properties of blood is difficult due to the non-homogenous nature of the blood itself. In addition, there is a lot of variation in the refractive indices reported in the literature. These are the reasons that motivated the researchers to develop a mathematical model that can be used to predict the refractive index of human blood as a function of concentration, temperature and wavelength. The experimental measurements were conducted on mimicking phantom hemoglobin samples using the Abbemat Refractometer. The results analysis revealed a linear relationship between the refractive index and concentration as well as temperature, and a non-linear relationship between refractive index and wavelength. These results are in agreement with those found in the literature. In addition, a new formula was developed based on empirical modelling which suggests that temperature and wavelength coefficients be added to the Barer formula. The verification of this correlation confirmed its ability to determine refractive index and/or blood hematocrit values with appropriate clinical accuracy.
van der Elst, Kim C. M.; Span, Lambert F. R.; van Hateren, Kai; Vermeulen, Karin M.; van der Werf, Tjip S.; Greijdanus, Ben; Kosterink, Jos G. W.; Uges, Donald R. A.
2013-01-01
Invasive aspergillosis and candidemia are important causes of morbidity and mortality in immunocompromised and critically ill patients. The triazoles voriconazole, fluconazole, and posaconazole are widely used for the treatment and prophylaxis of these fungal infections. Due to the variability of the pharmacokinetics of the triazoles among and within individual patients, therapeutic drug monitoring is important for optimizing the efficacy and safety of antifungal treatment. A dried blood spot (DBS) analysis was developed and was clinically validated for voriconazole, fluconazole, and posaconazole in 28 patients. Furthermore, a questionnaire was administered to evaluate the patients' opinions of the sampling method. The DBS analytical method showed linearity over the concentration range measured for all triazoles. Results for accuracy and precision were within accepted ranges; samples were stable at room temperature for at least 12 days; and different hematocrit values and blood spot volumes had no significant influence. The ratio of the drug concentration in DBS samples to that in plasma was 1.0 for voriconazole and fluconazole and 0.9 for posaconazole. Sixty percent of the patients preferred DBS analysis as a sampling method; 15% preferred venous blood sampling; and 25% had no preferred method. There was significantly less perception of pain with the DBS sampling method (P = 0.021). In conclusion, DBS analysis is a reliable alternative to venous blood sampling and can be used for therapeutic drug monitoring of voriconazole, fluconazole, and posaconazole. Patients were satisfied with DBS sampling and had less pain than with venous sampling. Most patients preferred DBS sampling to venous blood sampling. PMID:23896473
Sample to answer visualization pipeline for low-cost point-of-care blood cell counting
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter
2015-03-01
We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.
Inaba, Yoshimi; Herlihy, Amy S; Schwartz, Charles E; Skinner, Cindy; Bui, Quang M; Cobb, Joanna; Shi, Elva Z; Francis, David; Arvaj, Alison; Amor, David J; Pope, Kate; Wotton, Tiffany; Cohen, Jonathan; Hewitt, Jacqueline K; Hagerman, Randi J; Metcalfe, Sylvia A; Hopper, John L; Loesch, Danuta Z; Slater, Howard R; Godler, David E
2013-04-01
We show that a novel fragile X-related epigenetic element 2 FMR1 methylation test can be used along with a test for sex-determining region Y (SRY) to provide the option of combined fragile X syndrome and sex chromosome aneuploidy newborn screening. Fragile X-related epigenetic element 2, SRY, and FMR1 CGG repeat analyses were performed on blood and saliva DNA, and in adult and newborn blood spots. The cohort consisted of 159 controls (CGG <40), 187 premutation (CGG 56-170), and 242 full-mutation (CGG ~200-2,000) males and females, 106 sex chromosome aneuploidy individuals, and 151 cytogenetically normal controls. At the 0.435 threshold, fragile X-related epigenetic element 2 analysis in males was robust on both blood DNA and newborn blood spots, with specificity and sensitivity of ~100% for full-mutation genotype. In females, the specificity was 99%, whereas half of full-mutation females were above the 0.435 threshold in both blood DNA and newborn blood spots. Furthermore, at this threshold, the test could not differentiate individuals with Klinefelter syndrome from female controls without using the SRY marker. When combined with SRY analysis, the test was consistent with most results for sex chromosome aneuploidies from karyotyping. Setting specific thresholds for fragile X-related epigenetic element 2 analysis and including the SRY marker provides the option to either include or exclude detection of sex chromosome aneuploidies as part of fragile X syndrome newborn screening.
Silica Coated Paper Substrate for Paper-Spray Analysis of Therapeutic Drugs in Dried Blood Spots
Zhang, Zhiping; Xu, Wei; Manicke, Nicholas E.; Cooks, R. Graham; Ouyang, Zheng
2011-01-01
Paper spray is a newly developed ambient ionization method that has been applied for direct qualitative and quantitative analysis of biological samples. The properties of the paper substrate and spray solution have a significant impact on the release of chemical compounds from complex sample matrices, the diffusion of the analytes through the substrate, and the formation of ions for mass spectrometry analysis. In this study, a commercially available silica-coated paper was explored in an attempt to improve the analysis of therapeutic drugs in dried blood spots (DBS). The dichloromethane/isopropanol solvent has been identified as an optimal spray solvent for the analysis. The comparison was made with paper spray using chromatography paper as substrate with methanol/water as solvent for the analysis of verapamil, citalopram, amitriptyline, lidocaine and sunitinib in dried blood spots. It has been demonstrated the efficiency of recovery of the analytes was notably improved with the silica coated paper and the limit of quantitation (LOQ) for the drug analysis was 0.1 ng mL−1 using a commercial triple quadrupole mass spectrometer. The use of silica paper substrate also resulted in a sensitivity improvement of 5-50 fold in comparison with chromatography papers, including the Whatmann ET31 paper used for blood card. Analysis using a handheld miniature mass spectrometer Mini 11 gave LOQs of 10~20 ng mL−1 for the tested drugs, which is sufficient to cover the therapeutic ranges of these drugs. PMID:22145627
Zakaria, Rosita; Allen, Katrina J.; Koplin, Jennifer J.; Roche, Peter
2016-01-01
Introduction Through the introduction of advanced analytical techniques and improved throughput, the scope of dried blood spot testing utilising mass spectrometric methods, has broadly expanded. Clinicians and researchers have become very enthusiastic about the potential applications of dried blood spot based mass spectrometric applications. Analysts on the other hand face challenges of sensitivity, reproducibility and overall accuracy of dried blood spot quantification. In this review, we aim to bring together these two facets to discuss the advantages and current challenges of non-newborn screening applications of dried blood spot quantification by mass spectrometry. Methods To address these aims we performed a key word search of the PubMed and MEDLINE online databases in conjunction with individual manual searches to gather information. Keywords for the initial search included; “blood spot” and “mass spectrometry”; while excluding “newborn”; and “neonate”. In addition, databases were restricted to English language and human specific. There was no time period limit applied. Results As a result of these selection criteria, 194 references were identified for review. For presentation, this information is divided into: 1) clinical applications; and 2) analytical considerations across the total testing process; being pre-analytical, analytical and post-analytical considerations. Conclusions DBS analysis using MS applications is now broadly applied, with drug monitoring for both therapeutic and toxicological analysis being the most extensively reported. Several parameters can affect the accuracy of DBS measurement and further bridge experiments are required to develop adjustment rules for comparability between dried blood spot measures and the equivalent serum/plasma values. Likewise, the establishment of independent reference intervals for dried blood spot sample matrix is required. PMID:28149263
Yokokawa, Hirohide; Goto, Aya; Sanada, Hironobu; Watanabe, Tsuyoshi; Felder, Robin A; Jose, Pedro A; Yasumura, Seiji
2014-01-01
To determine success rates in controlling target blood pressures longitudinally by measuring several factors, including lifestyle characteristics associated with uncontrolled blood pressures for target treatment goals. This prospective observational cohort study (September 2008-September 2010) collected information on blood pressure control status and healthy lifestyle factors listed in Breslow's seven health practices through medical records and self-administered questionnaires from 884 of the 1264 Japanese hypertensive patients initially registered in the FRESH study. Multivariate analysis adjusted for associated factors was performed to estimate the association between lifestyle change and "uncontrolled blood pressures" at the final follow-up survey. Median age and proportion of men were 73 years and 39.1%, respectively. All survey failure rates were 37.6% among non-elderly patients (<65 years of age) without diabetes mellitus or chronic kidney disease, and 35.0% among patients with these diseases or myocardial infarction. Maintaining a healthy lifestyle was a protective factor against uncontrolled blood pressures in multivariate analysis. Obesity and smoking status were associated with uncontrolled blood pressures, and exercise frequency was borderline significance. The number of participants with healthy responses for these factors remained relatively low during follow up. Our study revealed low rates of controlled blood pressures, especially in non-elderly patients without diabetes mellitus or chronic kidney disease, and patients with these diseases or myocardial infarction. Our data indicate the need to maintain a healthy lifestyle, in particular, ideal body weight and adequate exercise frequency, for better hypertension management according to treatment guidelines. Copyright © 2013 Asian Oceanian Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.
Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Noori Hekmat, Somayeh; Esmailzdeh, Hamid
2014-12-25
Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts' panel views via the interview and focus group discussion sessions. The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ ("Theory of Inventive Problem Solving.") The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency.
Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Hekmat, Somayeh Noori; Esmailzdeh, Hamid
2015-01-01
Introduction: Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. Methodology: This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts’ panel views via the interview and focus group discussion sessions. Results: The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ (“Theory of Inventive Problem Solving.”) Conclusion: The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency. PMID:25560332
Haensch, Carl-Albrecht; Jörg, Johannes
2006-04-01
Extrasystoles occur in normal subjects but are significant more frequently (16.25% vs. 55%; chi(2) = 19.3; P < 0.001) seen in Parkinson's disease (PD) patients. The extrasystolic decreases in stroke volume and systolic pressure activate sympathetic vasomotor innervation and lead to a blood pressure increase for a few heartbeats. The purpose of this study was to prove whether the short time analysis of this blood pressure regulation allows the assessment of sympathetic neurocirculatory function. Records of noninvasive blood pressure monitoring were reviewed from 40 PD patients and 80 controls. A battery of cardiovascular autonomic tests, including Valsalva maneuver, tilt-table testing, echocardiography, and cardiac scintigraphy with [(123)I]meta-iodobenzylguanidine were performed. Fifty-five percent of the PD patients had at least one premature ventricular contraction (PVC) in 10 minutes lying supine at rest. After every PVC (13 PVCs) recorded from normal subjects, we found an increase in systolic blood pressure above base line with a maximum at the seventh heart beat. In all of the 22 PD patients, the systolic blood pressure was significantly decreased less than baseline in every PVC from the second to the ninth postextrasystolic beat (P < 0.001). In both groups, the extrasystolic fall in blood pressure was on average approximately 22%. The postextrasystolic potentiation did not differ (5.3% vs. 4.4%, not significant). If a PVC occurs, the analysis of short-time blood pressure regulation is a sensitive tool for baroreceptor reflex function. The advantage of this method results from the independence of patients cooperation and the high sensitivity to prove a sympathetic neurocirculatory failure within 10 heart beats. Copyright 2005 Movement Disorder Society.
Relating oxygen partial pressure, saturation and content: the haemoglobin-oxygen dissociation curve.
Collins, Julie-Ann; Rudenski, Aram; Gibson, John; Howard, Luke; O'Driscoll, Ronan
2015-09-01
The delivery of oxygen by arterial blood to the tissues of the body has a number of critical determinants including blood oxygen concentration (content), saturation (S O2 ) and partial pressure, haemoglobin concentration and cardiac output, including its distribution. The haemoglobin-oxygen dissociation curve, a graphical representation of the relationship between oxygen satur-ation and oxygen partial pressure helps us to understand some of the principles underpinning this process. Historically this curve was derived from very limited data based on blood samples from small numbers of healthy subjects which were manipulated in vitro and ultimately determined by equations such as those described by Severinghaus in 1979. In a study of 3524 clinical specimens, we found that this equation estimated the S O2 in blood from patients with normal pH and S O2 >70% with remarkable accuracy and, to our knowledge, this is the first large-scale validation of this equation using clinical samples. Oxygen saturation by pulse oximetry (S pO2 ) is nowadays the standard clinical method for assessing arterial oxygen saturation, providing a convenient, pain-free means of continuously assessing oxygenation, provided the interpreting clinician is aware of important limitations. The use of pulse oximetry reduces the need for arterial blood gas analysis (S aO2 ) as many patients who are not at risk of hypercapnic respiratory failure or metabolic acidosis and have acceptable S pO2 do not necessarily require blood gas analysis. While arterial sampling remains the gold-standard method of assessing ventilation and oxygenation, in those patients in whom blood gas analysis is indicated, arterialised capillary samples also have a valuable role in patient care. The clinical role of venous blood gases however remains less well defined.
Williamson, Wilby; Foster, Charlie; Reid, Hamish; Kelly, Paul; Lewandowski, Adam James; Boardman, Henry; Roberts, Nia; McCartney, David; Huckstep, Odaro; Newton, Julia; Dawes, Helen; Gerry, Stephen; Leeson, Paul
2016-07-01
Previous studies report benefits of exercise for blood pressure control in middle age and older adults, but longer-term effectiveness in younger adults is not well established. We performed a systematic review and meta-analysis of published randomized control trials with meta-regression of potential effect modifiers. An information specialist completed a comprehensive search of available data sources, including studies published up to June 2015. Authors applied strict inclusion and exclusion criteria to screen 9524 titles. Eligible studies recruited younger adults with a cardiovascular risk factor (with at least 25% of cohort aged 18-40 years); the intervention had a defined physical activity strategy and reported blood pressure as primary or secondary outcome. Meta-analysis included 14 studies randomizing 3614 participants, mean age 42.2±6.3 (SD) years. At 3 to 6 months, exercise was associated with a reduction in systolic blood pressure of -4.40 mm Hg (95% confidence interval, -5.78 to -3.01) and in diastolic blood pressure of -4.17 mm Hg (95% confidence interval, -5.42 to -2.93). Intervention effect was not significantly influenced by baseline blood pressure, body weight, or subsequent weight loss. Observed intervention effect was lost after 12 months of follow-up with no reported benefit over control, mean difference in systolic blood pressure -1.02 mm Hg (95% confidence interval, -2.34 to 0.29), and in diastolic blood pressure -0.91 mm Hg (95% confidence interval, -1.85 to 0.02). Current exercise guidance provided to reduce blood pressure in younger adults is unlikely to benefit long-term cardiovascular risk. There is need for continued research to improve age-specific strategies and recommendations for hypertension prevention and management in young adults. © 2016 The Authors.
Zheng, Zhi; Luo, Yuling; McMaster, Gary K
2006-07-01
Accurate and precise quantification of mRNA in whole blood is made difficult by gene expression changes during blood processing, and by variations and biases introduced by sample preparations. We sought to develop a quantitative whole-blood mRNA assay that eliminates blood purification, RNA isolation, reverse transcription, and target amplification while providing high-quality data in an easy assay format. We performed single- and multiplex gene expression analysis with multiple hybridization probes to capture mRNA directly from blood lysate and used branched DNA to amplify the signal. The 96-well plate singleplex assay uses chemiluminescence detection, and the multiplex assay combines Luminex-encoded beads with fluorescent detection. The single- and multiplex assays could quantitatively measure as few as 6000 and 24,000 mRNA target molecules (0.01 and 0.04 amoles), respectively, in up to 25 microL of whole blood. Both formats had CVs < 10% and dynamic ranges of 3-4 logs. Assay sensitivities allowed quantitative measurement of gene expression in the minority of cells in whole blood. The signals from whole-blood lysate correlated well with signals from purified RNA of the same sample, and absolute mRNA quantification results from the assay were similar to those obtained by quantitative reverse transcription-PCR. Both single- and multiplex assay formats were compatible with common anticoagulants and PAXgene-treated samples; however, PAXgene preparations induced expression of known antiapoptotic genes in whole blood. Both the singleplex and the multiplex branched DNA assays can quantitatively measure mRNA expression directly from small volumes of whole blood. The assay offers an alternative to current technologies that depend on RNA isolation and is amenable to high-throughput gene expression analysis of whole blood.
Quantitative blood group typing using surface plasmon resonance.
Then, Whui Lyn; Aguilar, Marie-Isabel; Garnier, Gil
2015-11-15
The accurate and reliable typing of blood groups is essential prior to blood transfusion. While current blood typing methods are well established, results are subjective and heavily reliant on analysis by trained personnel. Techniques for quantifying blood group antibody-antigen interactions are also very limited. Many biosensing systems rely on surface plasmon resonance (SPR) detection to quantify biomolecular interactions. While SPR has been widely used for characterizing antibody-antigen interactions, measuring antibody interactions with whole cells is significantly less common. Previous studies utilized SPR for blood group antigen detection, however, showed poor regeneration causing loss of functionality after a single use. In this study, a fully regenerable, multi-functional platform for quantitative blood group typing via SPR detection is achieved by immobilizing anti-human IgG antibody to the sensor surface, which binds to the Fc region of human IgG antibodies. The surface becomes an interchangeable platform capable of quantifying the blood group interactions between red blood cells (RBCs) and IgG antibodies. As with indirect antiglobulin tests (IAT), which use IgG antibodies for detection, IgG antibodies are initially incubated with RBCs. This facilitates binding to the immobilized monolayer and allows for quantitative blood group detection. Using the D-antigen as an example, a clear distinction between positive (>500 RU) and negative (<100 RU) RBCs is achieved using anti-D IgG. Complete regeneration of the anti-human IgG surface is also successful, showing negligible degradation of the surface after more than 100 regenerations. This novel approach is validated with human-sourced whole blood samples to demonstrate an interesting alternative for quantitative blood grouping using SPR analysis. Crown Copyright © 2015. Published by Elsevier B.V. All rights reserved.
Suspected hypoglycaemia in out patient practice: accuracy of dried blood spot analysis.
Parker, D R; Bargiota, A; Cowan, F J; Corrall, R J
1997-12-01
The assay of dried blood spots on filter paper to determine blood glucose concentration has been used to detect hypoglycaemia in out patients. We assessed the accuracy of this approach in assaying blood glucose concentrations in the hypoglycaemic range. Volunteers were rendered hypoglycaemic by intravenous infusion of insulin. The glucose concentration in simultaneously taken blood samples was measured either fresh or after drying on filter paper. Twenty-four healthy young volunteers and 9 patients with insulin-dependent diabetes were studied. Plasma glucose concentrations were measured using a standard auto analyser glucose oxidase method. Whole blood taken simultaneously was placed on prepared filter paper and allowed to dry; glucose concentration was then measured using a well-established technique. A correction factor was applied to convert the glucose concentration of plasma to that of whole blood. The relationship between glucose concentrations measured by the two methods was determined by regression coefficient. In the unequivocally hypoglycaemic range (plasma < or = 2.5 mmol/l), corrected dried blood spot glucose concentrations significantly correlated with standard plasma glucose concentrations (r = 0.81; P < 0.001). The dried blood spot method had a sensitivity of 91%. In the range designated probable hypoglycaemia (plasma < or = 3.3 mmol/l), there was also significant correlation (r = 0.90; P < 0.001) and the sensitivity was 96%. The specificity of the dried blood spot method was 100% in both ranges. Measurement of glucose concentrations in dried blood spots is specific and sensitive in the hypoglycaemic range. The present study indicates that hypoglycaemia may be excluded or confirmed respectively when levels in excess of 3.7 or below 2.8 mmol/l are found in uncorrected dried blood spot analysis.
Parsimonious model for blood glucose level monitoring in type 2 diabetes patients.
Zhao, Fang; Ma, Yan Fen; Wen, Jing Xiao; DU, Yan Fang; Li, Chun Lin; Li, Guang Wei
2014-07-01
To establish the parsimonious model for blood glucose monitoring in patients with type 2 diabetes receiving oral hypoglycemic agent treatment. One hundred and fifty-nine adult Chinese type 2 diabetes patients were randomized to receive rapid-acting or sustained-release gliclazide therapy for 12 weeks. Their blood glucose levels were measured at 10 time points in a 24 h period before and after treatment, and the 24 h mean blood glucose levels were measured. Contribution of blood glucose levels to the mean blood glucose level and HbA1c was assessed by multiple regression analysis. The correlation coefficients of blood glucose level measured at 10 time points to the daily MBG were 0.58-0.74 and 0.59-0.79, respectively, before and after treatment (P<0.0001). The multiple stepwise regression analysis showed that the blood glucose levels measured at 6 of the 10 time points could explain 95% and 97% of the changes in MBG before and after treatment. The three blood glucose levels, which were measured at fasting, 2 h after breakfast and before dinner, of the 10 time points could explain 84% and 86% of the changes in MBG before and after treatment, but could only explain 36% and 26% of the changes in HbA1c before and after treatment, and they had a poorer correlation with the HbA1c than with the 24 h MBG. The blood glucose levels measured at fasting, 2 h after breakfast and before dinner truly reflected the change 24 h blood glucose level, suggesting that they are appropriate for the self-monitoring of blood glucose levels in diabetes patients receiving oral anti-diabetes therapy. Copyright © 2014 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Whole-body vibration and blood flow and muscle oxygenation: a meta-analysis.
Games, Kenneth E; Sefton, JoEllen M; Wilson, Alan E
2015-05-01
The use and popularity of whole-body vibration (WBV) has increased in recent years, but there is a lack of consensus in the literature about the effectiveness of the treatment. To quantitatively examine the effects of WBV on muscle oxygenation and peripheral blood flow in healthy adults. We searched Web of Science and PubMed databases and reference lists from relevant articles using the key terms whole body vibration, whole-body vibration, WBV, blood flow, peripheral blood flow, oxygenation, muscle oxygenation, circulation, circulatory, near infrared spectroscopy, NIRS, and power Doppler. Key terms were searched using single word and combination searches. No date range was specified. Criteria for inclusion were (1) use of a commercially available WBV device, (2) a human research model, (3) a pre-WBV condition and at least 1 WBV experimental condition, and (4) reporting of unstandardized means and standard deviations of muscle oxygenation or peripheral blood flow. Means, standard deviations, and sample sizes were extracted from the text, tables, and figures of included studies. A total of 35 and 90 data points were extracted for the muscle-oxygenation and blood-flow meta-analyses, respectively. Data for each meta-analysis were combined and analyzed using meta-analysis software. Weighted, random-effects meta-analyses using the Hedges g metric were completed for muscle oxygenation and blood flow. We then conducted follow-up analyses using the moderator variables of vibration type, vibration time, vibration frequency, measurement location, and sample type. We found 18 potential articles. Further examination yielded 10 studies meeting the inclusion criteria. Whole-body vibration was shown to positively influence peripheral blood flow. Additionally, the moderators of vibration type and frequency altered the influence of WBV on blood flow. Overall, WBV did not alter muscle oxygenation; however, when the measurement site was considered, muscle oxygenation increased or decreased depending on the location. Acute bouts of WBV increase peripheral blood flow but do not alter skeletal muscle oxygenation. Vibration type appears to be the most important factor influencing both muscle oxygenation and peripheral blood flow.
Whole-Body Vibration and Blood Flow and Muscle Oxygenation: A Meta-Analysis
Games, Kenneth E.; Sefton, JoEllen M.; Wilson, Alan E.
2015-01-01
Context: The use and popularity of whole-body vibration (WBV) has increased in recent years, but there is a lack of consensus in the literature about the effectiveness of the treatment. Objective: To quantitatively examine the effects of WBV on muscle oxygenation and peripheral blood flow in healthy adults. Data Sources: We searched Web of Science and PubMed databases and reference lists from relevant articles using the key terms whole body vibration, whole-body vibration, WBV, blood flow, peripheral blood flow, oxygenation, muscle oxygenation, circulation, circulatory, near infrared spectroscopy, NIRS, and power Doppler. Key terms were searched using single word and combination searches. No date range was specified. Study Selection: Criteria for inclusion were (1) use of a commercially available WBV device, (2) a human research model, (3) a pre-WBV condition and at least 1 WBV experimental condition, and (4) reporting of unstandardized means and standard deviations of muscle oxygenation or peripheral blood flow. Data Extraction: Means, standard deviations, and sample sizes were extracted from the text, tables, and figures of included studies. A total of 35 and 90 data points were extracted for the muscle-oxygenation and blood-flow meta-analyses, respectively. Data for each meta-analysis were combined and analyzed using meta-analysis software. Weighted, random-effects meta-analyses using the Hedges g metric were completed for muscle oxygenation and blood flow. We then conducted follow-up analyses using the moderator variables of vibration type, vibration time, vibration frequency, measurement location, and sample type. Data Synthesis: We found 18 potential articles. Further examination yielded 10 studies meeting the inclusion criteria. Whole-body vibration was shown to positively influence peripheral blood flow. Additionally, the moderators of vibration type and frequency altered the influence of WBV on blood flow. Overall, WBV did not alter muscle oxygenation; however, when the measurement site was considered, muscle oxygenation increased or decreased depending on the location. Conclusions: Acute bouts of WBV increase peripheral blood flow but do not alter skeletal muscle oxygenation. Vibration type appears to be the most important factor influencing both muscle oxygenation and peripheral blood flow. PMID:25974682
Muñoz, Manuel; Ariza, Daniel; Campos, Arturo; Martín-Montañez, Elisa; Pavía, José
2013-01-01
Background Requirements for allogeneic red cell transfusion after total knee arthroplasty are still high (20–50%), and salvage and reinfusion of unwashed, filtered post-operative shed blood is an established method for reducing transfusion requirements following this operation. We performed a cost analysis to ascertain whether this alternative is likely to be cost-effective. Materials and methods Data from 1,093 consecutive primary total knee arthroplasties, managed with (reinfusion group, n=763) or without reinfusion of unwashed salvaged blood (control group, n=330), were retrospectively reviewed. The costs of low-vacuum drains, shed blood collection canisters (Bellovac ABT®, Wellspect HealthCare and ConstaVac CBC II®, Stryker), shed blood reinfusion, acquisition and transfusion of allogeneic red cell concentrate, haemoglobin measurements, and prolonged length of hospital stay were used for the blood management cost analysis. Results Patients in the reinfusion group received 152±64 mL of red blood cells from postoperatively salvaged blood, without clinically relevant incidents, and showed a lower allogeneic transfusion rate (24.5% vs 8.5%, for the control and reinfusion groups, respectively; p =0.001). There were no differences in post-operative infection rates. Patients receiving allogeneic transfusions stayed in hospital longer (+1.9 days [95% CI: 1.2 to 2.6]). As reinfusion of unwashed salvaged blood reduced the allogeneic transfusion rate, both reinfusion systems may provide net savings in different cost scenarios (€ 4.6 to € 106/patient for Bellovac ABT, and € −51.9 to € 49.9/patient for ConstaVac CBCII). Discussion Return of unwashed salvaged blood after total knee arthroplasty seems to save costs in patients with pre-operative haemoglobin between 12 and 15 g/dL. It is not cost-saving in patients with a pre-operative haemoglobin >15 g/dL, whereas in those with a pre-operative haemoglobin <12 g/dL, although cost-saving, its efficacy could be increased by associating some other blood-saving method. PMID:23149145
Gee, Michael S; Ghazani, Arezou A; Haq, Rizwan; Wargo, Jennifer A; Sebas, Matthew; Sullivan, Ryan J; Lee, Hakho; Weissleder, Ralph
2017-04-01
This study evaluates μNMR technology for molecular profiling of tumor fine needle aspirates and peripheral blood of melanoma patients. In vitro assessment of melanocyte (MART-1, HMB45) and MAP kinase signaling (pERK, pS6K) molecule expression was performed in human cell lines, while clinical validation was performed in an IRB-approved study of melanoma patients undergoing biopsy and blood sampling. Tumor FNA and blood specimens were compared with BRAF genetic analysis and cross-sectional imaging. μNMR in vitro analysis showed increased expression of melanocyte markers in melanoma cells as well as increased expression of phosphorylated MAP kinase targets in BRAF-mutant melanoma cells. Melanoma patient FNA samples showed increased pERK and pS6K levels in BRAF mutant compared with BRAF WT melanomas, with μNMR blood circulating tumor cell level increased with higher metastatic burden visible on imaging. These results indicate that μNMR technology provides minimally invasive point-of-care evaluation of tumor signaling and metastatic burden in melanoma patients. Copyright © 2016 Elsevier Inc. All rights reserved.
Hossain, Ahmed; Beyene, Joseph
2014-01-01
This article compares baseline, average, and longitudinal data analysis methods for identifying genetic variants in genome-wide association study using the Genetic Analysis Workshop 18 data. We apply methods that include (a) linear mixed models with baseline measures, (b) random intercept linear mixed models with mean measures outcome, and (c) random intercept linear mixed models with longitudinal measurements. In the linear mixed models, covariates are included as fixed effects, whereas relatedness among individuals is incorporated as the variance-covariance structure of the random effect for the individuals. The overall strategy of applying linear mixed models decorrelate the data is based on Aulchenko et al.'s GRAMMAR. By analyzing systolic and diastolic blood pressure, which are used separately as outcomes, we compare the 3 methods in identifying a known genetic variant that is associated with blood pressure from chromosome 3 and simulated phenotype data. We also analyze the real phenotype data to illustrate the methods. We conclude that the linear mixed model with longitudinal measurements of diastolic blood pressure is the most accurate at identifying the known single-nucleotide polymorphism among the methods, but linear mixed models with baseline measures perform best with systolic blood pressure as the outcome.
Assessing human metal accumulations in an urban superfund site.
Hailer, M Katie; Peck, Christopher P; Calhoun, Michael W; West, Robert F; James, Kyle J; Siciliano, Steven D
2017-09-01
Butte, Montana is part of the largest superfund site in the continental United States. Open-pit mining continues in close proximity to Butte's urban population. This study seeks to establish baseline metal concentrations in the hair and blood of individuals living in Butte, MT and possible routes of exposure. Volunteers from Butte (n=116) and Bozeman (n=86) were recruited to submit hair and blood samples and asked to complete a lifestyle survey. Elemental analysis of hair and blood samples was performed by ICP-MS. Three air monitors were stationed in Butte to collect particulate and filters were analyzed by ICP-MS. Soil samples from the yards of Butte volunteers were quantified by ICP-MS. Hair analysis revealed concentrations of Al, As, Cd, Cu, Mn, Mo, and U to be statistically elevated in Butte's population. Blood analysis revealed that the concentration of As was also statistically elevated in the Butte population. Multiple regression analysis was performed for the elements As, Cu, and Mn for hair and blood samples. Soil samples revealed detectable levels of As, Pb, Cu, Mn, and Cd, with As and Cu levels being higher than expected in some of the samples. Air sampling revealed consistently elevated As and Mn levels in the larger particulate sampled as compared to average U.S. ambient air data. Copyright © 2017 Elsevier B.V. All rights reserved.
Automated classification and quantitative analysis of arterial and venous vessels in fundus images
NASA Astrophysics Data System (ADS)
Alam, Minhaj; Son, Taeyoon; Toslak, Devrim; Lim, Jennifer I.; Yao, Xincheng
2018-02-01
It is known that retinopathies may affect arteries and veins differently. Therefore, reliable differentiation of arteries and veins is essential for computer-aided analysis of fundus images. The purpose of this study is to validate one automated method for robust classification of arteries and veins (A-V) in digital fundus images. We combine optical density ratio (ODR) analysis and blood vessel tracking algorithm to classify arteries and veins. A matched filtering method is used to enhance retinal blood vessels. Bottom hat filtering and global thresholding are used to segment the vessel and skeleton individual blood vessels. The vessel tracking algorithm is used to locate the optic disk and to identify source nodes of blood vessels in optic disk area. Each node can be identified as vein or artery using ODR information. Using the source nodes as starting point, the whole vessel trace is then tracked and classified as vein or artery using vessel curvature and angle information. 50 color fundus images from diabetic retinopathy patients were used to test the algorithm. Sensitivity, specificity, and accuracy metrics were measured to assess the validity of the proposed classification method compared to ground truths created by two independent observers. The algorithm demonstrated 97.52% accuracy in identifying blood vessels as vein or artery. A quantitative analysis upon A-V classification showed that average A-V ratio of width for NPDR subjects with hypertension decreased significantly (43.13%).
State of the art in bile analysis in forensic toxicology.
Bévalot, F; Cartiser, N; Bottinelli, C; Guitton, J; Fanton, L
2016-02-01
In forensic toxicology, alternative matrices to blood are useful in case of limited, unavailable or unusable blood sample, suspected postmortem redistribution or long drug intake-to-sampling interval. The present article provides an update on the state of knowledge for the use of bile in forensic toxicology, through a review of the Medline literature from 1970 to May 2015. Bile physiology and technical aspects of analysis (sampling, storage, sample preparation and analytical methods) are reported, to highlight specificities and consequences from an analytical and interpretative point of view. A table summarizes cause of death and quantification in bile and blood of 133 compounds from more than 200 case reports, providing a useful tool for forensic physicians and toxicologists involved in interpreting bile analysis. Qualitative and quantitative interpretation is discussed. As bile/blood concentration ratios are high for numerous molecules or metabolites, bile is a matrix of choice for screening when blood concentrations are low or non-detectable: e.g., cases of weak exposure or long intake-to-death interval. Quantitative applications have been little investigated, but small molecules with low bile/blood concentration ratios seem to be good candidates for quantitative bile-based interpretation. Further experimental data on the mechanism and properties of biliary extraction of xenobiotics of forensic interest are required to improve quantitative interpretation. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
[Improvement and process optimization transfusion in Morocco: proposal of a new organization].
Bennis, I; Janah, S; Benajiba, M
2013-03-01
Propose a new organization for the Moroccan blood transfusion system. Through an analysis of several aspects of the current organization, both qualitatively and quantitatively (Statistics 2011), it was found that several failures of the current system prevent them from achieving it's objectives and ensuring its responsibilities. Using multiple-criteria decision analysis (ELECTRE III), a new organization based on resources pooling is proposed. This new organization concerns the status of the National Blood Transfusion Center, donor management, the geographical location of the various regional centers, logistics, inventory management and the information system. Within the new organization proposed, the number of regional Centers for blood transfusion is reduced from 16 to 7 in accordance with the existing constraints, while redefining the roles of each site. The aspects of inventory management, the information system, increasing the number of donors, the policy communication and marketing and cycle of blood collection and distribution are also redefined. This proposed new organization will provide decision makers with the necessary assistance for decision making, whit respect to the improvement of the entire system Moroccan blood transfusion system. And so help achieving the desired objectives on ensuring blood availability and it' maximum safety. The simulation of this proposal should confirm the choice that was made. Further analysis of complementary aspects such as the financial aspect or human resources, would moreover contribute to refining this proposal. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
White blood cell counting analysis of blood smear images using various segmentation strategies
NASA Astrophysics Data System (ADS)
Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza
2017-09-01
In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.
Ariizumi, Takashi; Kawashima, Hiroyuki; Ogose, Akira; Sasaki, Taro; Hotta, Tetsuo; Hatano, Hiroshi; Morita, Tetsuro; Endo, Naoto
2018-01-01
The value of routine blood tests in malignant soft tissue tumors remains uncertain. To determine if these tests can be used for screening, the routine pretreatment blood test findings were retrospectively investigated in 359 patients with benign and malignant soft tissue tumors. Additionally, the prognostic potential of pretreatment blood abnormalities was evaluated in patients with soft tissue sarcomas. We compared clinical factors and blood tests findings between patients with benign and malignant soft tissue tumors using univariate and multivariate analysis. Subsequently, patients with malignant tumors were divided into two groups based on blood test reference values, and the prognostic significance of each parameter was evaluated. In the univariate analysis, age, tumor size, and tumor depth were significant clinical diagnostic factors. Significant increases in the granulocyte count, C-reactive protein (CRP) level, erythrocyte sedimentation rate (ESR), and γ-glutamyl transpeptidase (γ-GTP) levels were found in patients with malignant soft tissue tumors. Multiple logistic regression showed that tumor size and ESR were independent factors that predicted malignant soft tissue tumors. The Kaplan-Meier survival analysis revealed that granulocyte counts, γ-GTP levels, and CRP levels correlated significantly with overall survival. Thus, pretreatment routine blood tests are useful diagnostic and prognostic markers for diagnosing soft tissue sarcoma. © 2018 by the Association of Clinical Scientists, Inc.
Larsen, V H; Waldau, T; Gravesen, H; Siggaard-Andersen, O
1996-01-01
To describe a clinical case where an extremely low erythrocyte 2,3-diphosphoglycerate concentration (2,3-DPG) was discovered by routine blood gas analysis supplemented by computer calculation of derived quantities. The finding of a low 2,3-DPG revealed a severe hypophosphatemia. Open uncontrolled study of a patient case. Intensive care observation during 41 days. A 44 year old woman with an abdominal abscess. Surgical drainage, antibiotics and parenteral nutrition. daily routine blood gas analyses with computer calculation of the hemoglobin oxygen affinity and estimation of the 2,3-DPG. An abrupt decline of 2,3-DPG was observed late in the course coincident with a pronounced hypophosphatemia. The fall in 2,3-DPG was verified by enzymatic analysis. 2,3-DPG may be estimated by computer calculation of routine blood gas data. A low 2,3-DPG which may be associated with hypophosphatemia causes an unfavorable increase in hemoglobin oxygen affinity which reduces the oxygen release to the tissues.
Forcier, Kathleen; Stroud, Laura R; Papandonatos, George D; Hitsman, Brian; Reiches, Meredith; Krishnamoorthy, Jenelle; Niaura, Raymond
2006-11-01
A meta-analysis of published studies with adult human participants was conducted to evaluate whether physical fitness attenuates cardiovascular reactivity and improves recovery from acute psychological stressors. Thirty-three studies met selection criteria; 18 were included in recovery analyses. Effect sizes and moderator influences were calculated by using meta-analysis software. A fixed effects model was fit initially; however, between-studies heterogeneity could not be explained even after inclusion of moderators. Therefore, to account for residual heterogeneity, a random effects model was estimated. Under this model, fit individuals showed significantly attenuated heart rate and systolic blood pressure reactivity and a trend toward attenuated diastolic blood pressure reactivity. Fit individuals also showed faster heart rate recovery, but there were no significant differences in systolic blood pressure or diastolic blood pressure recovery. No significant moderators emerged. Results have important implications for elucidating mechanisms underlying effects of fitness on cardiovascular disease and suggest that fitness may be an important confound in studies of stress reactivity. Copyright 2006 APA, all rights reserved.
Exsanguinated blood volume estimation using fractal analysis of digital images.
Sant, Sonia P; Fairgrieve, Scott I
2012-05-01
The estimation of bloodstain volume using fractal analysis of digital images of passive blood stains is presented. Binary digital photos of bloodstains of known volumes (ranging from 1 to 7 mL), dispersed in a defined area, were subjected to image analysis using FracLac V. 2.0 for ImageJ. The box-counting method was used to generate a fractal dimension for each trial. A positive correlation between the generated fractal number and the volume of blood was found (R(2) = 0.99). Regression equations were produced to estimate the volume of blood in blind trials. An error rate ranging from 78% for 1 mL to 7% for 6 mL demonstrated that as the volume increases so does the accuracy of the volume estimation. This method used in the preliminary study proved that bloodstain patterns may be deconstructed into mathematical parameters, thus removing the subjective element inherent in other methods of volume estimation. © 2012 American Academy of Forensic Sciences.
A Laboratory Exercise to Determine Human ABO Blood Type by Noninvasive Methods
ERIC Educational Resources Information Center
Martin, Michael P.; Detzel, Stephen M.
2008-01-01
Analysis of single-nucleotide polymorphisms and their association with diseases and nondisease phenotypes is of growing importance in human biology studies. In this laboratory exercise, students determine the genetic basis for their ABO blood type; however, no blood is drawn. Students isolate genomic DNA from buccal mucosa cells that are present…
Image classification of unlabeled malaria parasites in red blood cells.
Zheng Zhang; Ong, L L Sharon; Kong Fang; Matthew, Athul; Dauwels, Justin; Ming Dao; Asada, Harry
2016-08-01
This paper presents a method to detect unlabeled malaria parasites in red blood cells. The current "gold standard" for malaria diagnosis is microscopic examination of thick blood smear, a time consuming process requiring extensive training. Our goal is to develop an automate process to identify malaria infected red blood cells. Major issues in automated analysis of microscopy images of unstained blood smears include overlapping cells and oddly shaped cells. Our approach creates robust templates to detect infected and uninfected red cells. Histogram of Oriented Gradients (HOGs) features are extracted from templates and used to train a classifier offline. Next, the ViolaJones object detection framework is applied to detect infected and uninfected red cells and the image background. Results show our approach out-performs classification approaches with PCA features by 50% and cell detection algorithms applying Hough transforms by 24%. Majority of related work are designed to automatically detect stained parasites in blood smears where the cells are fixed. Although it is more challenging to design algorithms for unstained parasites, our methods will allow analysis of parasite progression in live cells under different drug treatments.
Passive bloodstains: from an impact energy to a final dried pattern
NASA Astrophysics Data System (ADS)
Smith, Fiona; Brutin, David
2016-11-01
Tracking down the origin of a blood droplet present on a crime scene has become of major importance in bloodstain pattern analysis. Passive bloodstains are not yet well understood. Accordingly the purpose of this research is to provide new tools to forensic investigators in the analysis of bloodstains arising from blood droplets dripping naturally. The study aims to understand the link between the final dried pattern of a passive bloodstain and its impact energy. Currently no such tool exists, and no correlation has yet been proven. This research was therefore focusing on a new parameter, the thicker outer rim observed on the dried final pattern. To do so, we created several passive bloodstains with different impact energies. A correlation was highlighted between the inner diameter, the maximum spreading diameter, the initial diameter of a blood droplet and its impact energy. This correlation shows how the drying mechanism of a blood droplet is influenced by its impact energy as it alters the red blood cells dispersion inside the droplet. The biological deposit and the final dried pattern are subsequently modified. ANR funded project: D-Blood Project.
Boyle, Rebecca R; McLean, Stuart; Brandon, Sue; Pass, Georgia J; Davies, Noel W
2002-11-25
We have developed two solid-phase microextraction (SPME) methods, coupled with gas chromatography, for quantitatively analysing the major Eucalyptus leaf terpene, 1,8-cineole, in both expired air and blood from the common brushtail possum (Trichosurus vulpecula). In-line SPME sampling (5 min at 20 degrees C room temperature) of excurrent air from an expiratory chamber containing a possum dosed orally with 1,8-cineole (50 mg/kg) allowed real-time semi-quantitative measurements reflecting 1,8-cineole blood concentrations. Headspace SPME using 50 microl whole blood collected from possums dosed orally with 1,8-cineole (30 mg/kg) resulted in excellent sensitivity (quantitation limit 1 ng/ml) and reproducibility. Blood concentrations ranged between 1 and 1380 ng/ml. Calibration curves were prepared for two concentration ranges (0.05-10 and 10-400 ng/50 microl) for the analysis of blood concentrations. Both calibration curves were linear (r(2)=0.999 and 0.994, respectively) and the equations for the two concentration ranges were consistent. Copyright 2002 Elsevier Science B.V.
Pleomorphic Structures in Human Blood Are Red Blood Cell-Derived Microparticles, Not Bacteria.
Mitchell, Adam J; Gray, Warren D; Schroeder, Max; Yi, Hong; Taylor, Jeannette V; Dillard, Rebecca S; Ke, Zunlong; Wright, Elizabeth R; Stephens, David; Roback, John D; Searles, Charles D
2016-01-01
Red blood cell (RBC) transfusions are a common, life-saving therapy for many patients, but they have also been associated with poor clinical outcomes. We identified unusual, pleomorphic structures in human RBC transfusion units by negative-stain electron microscopy that appeared identical to those previously reported to be bacteria in healthy human blood samples. The presence of viable, replicating bacteria in stored blood could explain poor outcomes in transfusion recipients and have major implications for transfusion medicine. Here, we investigated the possibility that these structures were bacteria. Flow cytometry, miRNA analysis, protein analysis, and additional electron microscopy studies strongly indicated that the pleomorphic structures in the supernatant of stored RBCs were RBC-derived microparticles (RMPs). Bacterial 16S rDNA PCR amplified from these samples were sequenced and was found to be highly similar to species that are known to commonly contaminate laboratory reagents. These studies suggest that pleomorphic structures identified in human blood are RMPs and not bacteria, and they provide an example in which laboratory contaminants may can mislead investigators.
Qin, Xiao-Yan; Feng, Jin-Chao; Cao, Chang; Wu, Huan-Tong; Loh, Y Peng; Cheng, Yong
2016-11-01
Accumulating evidence suggests that brain-derived neurotrophic factor (BDNF) may be implicated in the developmental outcomes of children with autism spectrum disorder (ASD). To use meta-analysis to determine whether children with ASD have altered peripheral blood levels of BDNF. A systematic search of PubMed, PsycINFO, and Web of Science was performed for English-language literature through February 7, 2016. The search terms included brain-derived neurotrophic factor or BDNF in combination with autism, without year restriction. Two additional records were retrieved after a review of the reference lists of selected articles. Studies were included if they provided data on peripheral blood levels of BDNF in children with ASD and healthy control children. Studies that included adults or with overlapping samples were excluded. Data were extracted by 2 independent observers from 19 included studies. Data were pooled using a random-effects model with Comprehensive Meta-analysis software. Blood levels of BDNF in children with ASD compared with healthy controls. Altered levels of BDNF were hypothesized to be related to ASD. This meta-analysis included 19 studies with 2896 unique participants. Random-effects meta-analysis of all 19 studies showed that children with ASD had significantly increased peripheral blood levels of BDNF compared with healthy controls (Hedges g, 0.490; 95% CI, 0.185-0.794; P = .002). Subgroup analyses in 4 studies revealed that neonates diagnosed with ASD later in life had no association with blood levels of BDNF (Hedges g, 0.384; 95% CI, -0.244 to 1.011; P = .23), whereas children in the nonneonate ASD group (15 studies) demonstrated significantly increased BDNF levels compared with healthy controls (Hedges g, 0.524; 95% CI, 0.206 to 0.842; P = .001). Further analysis showed that children in the nonneonate ASD group had increased BDNF levels in serum (10 studies) (Hedges g, 0.564; 95% CI, 0.168 to 0.960; P = .005) but not in plasma (5 studies) (Hedges g, 0.436; 95% CI, -0.176 to 1.048; P = .16). Meta-regression analyses revealed that sample size had a moderating effect on the outcome of the meta-analysis in the nonneonate group. In addition, no publication bias was found in the meta-analysis. Children with ASD have increased peripheral blood levels of BDNF, strengthening the clinical evidence of an abnormal neurotrophic factor profile in this population.
Behr-Gross, M-E; Heiden, M; Norda, R
2013-05-01
In November 2009, the Council of Europe's Blood Transfusion Steering Committee created a group of experts to explore the problem of behaviors having an impact on the management of donors of blood and blood components and on blood transfusion safety in Europe. This ad hoc group sought a harmonised interpretation of temporary exclusion (or temporary deferral), as opposed to permanent exclusion (or permanent deferral), in the context of the selection of donors of blood and blood components. It was also given the mandate to assess, on the basis of available data, the possibility of differentiating "at risk" behaviours from behaviours "at high risk" of contamination by serious infectious diseases transmitted by blood, blood components or derived therapeutic products. The primary objective of this work was to ensure the safety of blood, blood components and derived therapeutic products for future recipients by promoting a risk analysis-based approach, given that some countries envisaged amending their provisions for donor selection. However, a risk analysis can only be performed on groups, not individuals, which may give the impression of a discriminatory approach, so it needed to be justified in the context of transfusion safety. A collaborative project, which included an investigation phase, led to the drafting of a technical memorandum that summarised the data collected in ten Council of Europe member states on the selection criteria for blood donors and the epidemiology of infectious diseases (with a focus on human immunodeficiency virus) in the general population and among blood donors. The technical memorandum was published in 2011 on the European Directorate for the Quality of Medicines and Healthcare website dedicated to this project. A draft resolution of the Committee of Ministers of the Council of Europe was then developed by the Council of Europe's Blood Transfusion Steering Committee. This text was circulated among member and observer states of the Council of Europe for review and comments. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Comparison of algorithms for blood stain detection applied to forensic hyperspectral imagery
NASA Astrophysics Data System (ADS)
Yang, Jie; Messinger, David W.; Mathew, Jobin J.; Dube, Roger R.
2016-05-01
Blood stains are among the most important types of evidence for forensic investigation. They contain valuable DNA information, and the pattern of the stains can suggest specifics about the nature of the violence that transpired at the scene. Early detection of blood stains is particularly important since the blood reacts physically and chemically with air and materials over time. Accurate identification of blood remnants, including regions that might have been intentionally cleaned, is an important aspect of forensic investigation. Hyperspectral imaging might be a potential method to detect blood stains because it is non-contact and provides substantial spectral information that can be used to identify regions in a scene with trace amounts of blood. The potential complexity of scenes in which such vast violence occurs can be high when the range of scene material types and conditions containing blood stains at a crime scene are considered. Some stains are hard to detect by the unaided eye, especially if a conscious effort to clean the scene has occurred (we refer to these as "latent" blood stains). In this paper we present the initial results of a study of the use of hyperspectral imaging algorithms for blood detection in complex scenes. We describe a hyperspectral imaging system which generates images covering 400 nm - 700 nm visible range with a spectral resolution of 10 nm. Three image sets of 31 wavelength bands were generated using this camera for a simulated indoor crime scene in which blood stains were placed on a T-shirt and walls. To detect blood stains in the scene, Principal Component Analysis (PCA), Subspace Reed Xiaoli Detection (SRXD), and Topological Anomaly Detection (TAD) algorithms were used. Comparison of the three hyperspectral image analysis techniques shows that TAD is most suitable for detecting blood stains and discovering latent blood stains.
McCulloh, Russell J; Koster, Michael P; Yin, Dwight E; Milner, Tiffany L; Ralston, Shawn L; Hill, Vanessa L; Alverson, Brian K; Biondi, Eric A
2015-01-01
Blood cultures are often recommended for the evaluation of community-acquired pneumonia (CAP). However, institutions vary in their use of blood cultures, and blood cultures have unclear utility in CAP management in hospitalized children. To identify clinical factors associated with obtaining blood cultures in children hospitalized with CAP, and to estimate the association between blood culture obtainment and hospital length of stay (LOS). We performed a multicenter retrospective cohort study of children admitted with a diagnosis of CAP to any of four pediatric hospitals in the United States from January 1, 2011-December 31, 2012. Demographics, medical history, diagnostic testing, and clinical outcomes were abstracted via manual chart review. Multivariable logistic regression evaluated patient and clinical factors for associations with obtaining blood cultures. Propensity score-matched Kaplan-Meier analysis compared patients with and without blood cultures for hospital LOS. Six hundred fourteen charts met inclusion criteria; 390 children had blood cultures obtained. Of children with blood cultures, six (1.5%) were positive for a pathogen and nine (2.3%) grew a contaminant. Factors associated with blood culture obtainment included presenting with symptoms of systemic inflammatory response syndrome (OR 1.78, 95% CI 1.10-2.89), receiving intravenous hydration (OR 3.94, 95% CI 3.22-4.83), receiving antibiotics before admission (OR 1.49, 95% CI 1.17-1.89), hospital admission from the ED (OR 1.65, 95% CI 1.05-2.60), and having health insurance (OR 0.42, 95% CI 0.30-0.60). In propensity score-matched analysis, patients with blood cultures had median 0.8 days longer LOS (2.0 vs 1.2 days, P < .0001) without increased odds of readmission (OR 0.94, 95% CI 0.45-1.97) or death (P = .25). Obtaining blood cultures in children hospitalized with CAP rarely identifies a causative pathogen and is associated with increased LOS. Our results highlight the need to refine the role of obtaining blood cultures in children hospitalized with CAP.
Evaluation of Blood Glucose Meter Efficacy in an Antenatal Diabetes Clinic.
McGrath, Rachel T; Donnelly, Vanessa C; Glastras, Sarah J; Preda, Veronica A; Sheriff, Nisa; Ward, Peter; Hocking, Samantha L; Fulcher, Gregory R
2016-02-01
The optimal treatment of diabetes in pregnancy requires accurate measurement of blood glucose levels, in order to minimize adverse outcomes for both mother and neonate. Self-monitoring of blood glucose is routinely used to measure glycemic control and to assess whether treatment targets are being met; however, the accuracy of blood glucose meters in pregnancy is unclear. Pregnant women with gestational, type 1, or type 2 diabetes mellitus were eligible to participate. Nonfasting capillary blood glucose levels were measured in duplicate using the BGStar(®) (Sanofi, Sydney, Australia) and FreeStyle Lite(®) (Abbott, Sydney) blood glucose meters. Venous blood samples were collected and analyzed for plasma glucose, hematocrit, and glycated hemoglobin. Capillary blood glucose was compared with plasma glucose and further assessed according to International Organization for Standardization (ISO) 15197:2013 standards. One hundred ten women were recruited, providing 96 samples suitable for analysis. The mean ± SD laboratory plasma glucose level was 4.6 ± 1.4 mmol/L; the BGStar and FreeStyle Lite capillary blood glucose values were 5.3 ± 1.4 mmol/L and 5.0 ± 1.3 mmol/L, respectively. Both meters showed a positive bias (0.42 mmol/L for the FreeStyle Lite and 0.65 mmol/L for the BGStar). Furthermore, neither meter fulfilled the ISO 15197:2013 standards, and there was a nonsignificant improvement in meter performance at blood glucose levels of ≤4.2 mmol/L. Hematocrit did not affect the results of either blood glucose meter. Clarke Error Grid analysis demonstrated that approximately 70% of the results of both meters would lead to appropriate clinical action. The BGStar and FreeStyle Lite blood glucose meters did not meet ISO 15197:2013 recommendations for blood glucose monitoring systems when assessed in a population of women with diabetes in pregnancy. Clinicians should consider this difference in blood glucose readings when making diabetes-related treatment decisions.
High-speed video analysis of forward and backward spattered blood droplets.
Comiskey, P M; Yarin, A L; Attinger, D
2017-07-01
High-speed videos of blood spatter due to a gunshot taken by the Ames Laboratory Midwest Forensics Resource Center (MFRC) [1] are analyzed. The videos used in this analysis were focused on a variety of targets hit by a bullet which caused either forward, backward, or both types of blood spatter. The analysis process utilized particle image velocimetry (PIV) and particle analysis software to measure drop velocities as well as the distributions of the number of droplets and their respective side view area. The results of this analysis revealed that the maximal velocity in the forward spatter can be about 47±5m/s and for the backward spatter - about 24±8m/s. Moreover, our measurements indicate that the number of droplets produced is larger in forward spatter than it is in backward spatter. In the forward and backward spatter the droplet area in the side-view images is approximately the same. The upper angles of the close-to-cone domain in which droplets are issued in forward and backward spatter are, 27±9° and 57±7°, respectively, whereas the lower angles of the close-to-cone domain are 28±12° and 30±18°, respectively. The inclination angle of the bullet as it penetrates the target is seen to play a large role in the directional preference of the spattered blood. Also, muzzle gases, bullet impact angle, as well as the aerodynamic wake of the bullet are seen to greatly influence the flight of the droplets. The intent of this investigation is to provide a quantitative basis for current and future research on bloodstain pattern analysis (BPA) of either forward or backward blood spatter due to a gunshot. Published by Elsevier B.V.
Blood, urine, and hair kinetic analysis following an acute lead intoxication.
Ho, G; Keutgens, A; Schoofs, R; Kotolenko, S; Denooz, R; Charlier, C
2011-01-01
A case of lead exposure resulting from the accidental ingestion of a lead-containing solution is reported. Because of clinical management rapidly performed through chelation therapy by 2,3-dimercaptopropane sulfonate sodium and meso-2,3-dimercaptosuccinic acid, blood lead levels of this 51-year-old patient were moderate (412.9 μg/L) and no clinical symptoms were observed. Numerous blood and urine samples were collected for kinetic analysis of lead elimination. However, we report the first case in which hair samples were analyzed to determine the excretion level of lead after acute intoxication.
Atlas of computerized blood flow analysis in bone disease.
Gandsman, E J; Deutsch, S D; Tyson, I B
1983-11-01
The role of computerized blood flow analysis in routine bone scanning is reviewed. Cases illustrating the technique include proven diagnoses of toxic synovitis, Legg-Perthes disease, arthritis, avascular necrosis of the hip, fractures, benign and malignant tumors, Paget's disease, cellulitis, osteomyelitis, and shin splints. Several examples also show the use of the technique in monitoring treatment. The use of quantitative data from the blood flow, bone uptake phase, and static images suggests specific diagnostic patterns for each of the diseases presented in this atlas. Thus, this technique enables increased accuracy in the interpretation of the radionuclide bone scan.
Discriminant analysis of Raman spectra for body fluid identification for forensic purposes.
Sikirzhytski, Vitali; Virkler, Kelly; Lednev, Igor K
2010-01-01
Detection and identification of blood, semen and saliva stains, the most common body fluids encountered at a crime scene, are very important aspects of forensic science today. This study targets the development of a nondestructive, confirmatory method for body fluid identification based on Raman spectroscopy coupled with advanced statistical analysis. Dry traces of blood, semen and saliva obtained from multiple donors were probed using a confocal Raman microscope with a 785-nm excitation wavelength under controlled laboratory conditions. Results demonstrated the capability of Raman spectroscopy to identify an unknown substance to be semen, blood or saliva with high confidence.
Cerebral edema, mass effects, and regional blood volume in man.
Penn, R D; Kurtz, D
1977-03-01
The authors conducted quantitative analysis of computerized tomography (CT) scans to measure tumor size, cerebral edema, and regional blood volume in man. Mass lesions without edema caused a local reduction in blood volume. Cerebral edema also reduced blood volume in proportion to its severity. Consideration of the electrolyte changes and water shifts in white-matter edema suggested that the decrease in absorption coefficient seen in CT scans was due to the increase in water content. Thus, in cerebral edema separation of blood vessels as well as increased interstitial pressure decrease blood volume, and the regional differences in turn reflect pressure gradients within the brain.
Aristov, Alexander; Nosova, Ekaterina
2017-04-01
The paper focuses on research aimed at creating and testing a new approach to evaluate the processes of aggregation and sedimentation of red blood cells for purpose of its use in clinical laboratory diagnostics. The proposed method is based on photometric analysis of blood sample formed as a sessile drop. The results of clinical approbation of this method are given in the paper. Analysis of the processes occurring in the sample in the form of sessile drop during the process of blood cells sedimentation is described. The results of experimental studies to evaluate the effect of the droplet sample focusing properties on light radiation transmittance are presented. It is shown that this method significantly reduces the sample volume and provides sufficiently high sensitivity to the studied processes.
Kleber, Christian; Becker, Christopher A; Malysch, Tom; Reinhold, Jens M; Tsitsilonis, Serafeim; Duda, Georg N; Schmidt-Bleek, Katharina; Schaser, Klaus D
2015-07-01
Hemorrhagic shock (hS) interacts with the posttraumatic immune response and fracture healing in multiple trauma. Due to the lack of a long-term survival multiple trauma animal models, no standardized analysis of fracture healing referring the impact of multiple trauma on fracture healing was performed. We propose a new long-term survival (21 days) murine multiple trauma model combining hS (microsurgical cannulation of carotid artery, withdrawl of blood and continuously blood pressure measurement), femoral (osteotomy/external fixation) and tibial fracture (3-point bending technique/antegrade nail). The posttraumatic immune response was measured via IL-6, sIL-6R ELISA. The hS was investigated via macrohemodynamics, blood gas analysis, wet-dry lung ration and histologic analysis of the shock organs. We proposed a new murine long-term survival (21 days) multiple trauma model mimicking clinical relevant injury patterns and previously published human posttraumatic immune response. Based on blood gas analysis and histologic analysis of shock organs we characterized and standardized our murine multiple trauma model. Furthermore, we revealed hemorrhagic shock as a causative factor that triggers sIL-6R formation underscoring the fundamental pathophysiologic role of the transsignaling mechanism in multiple trauma. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
Kaur, Inderjeet; Zeeshan, Mohammad; Saini, Ekta; Kaushik, Abhinav; Mohmmed, Asif; Gupta, Dinesh; Malhotra, Pawan
2016-10-20
Post-transcriptional and post-translational modifications play a major role in Plasmodium life cycle regulation. Lysine methylation of histone proteins is well documented in several organisms, however in recent years lysine methylation of proteins outside histone code is emerging out as an important post-translational modification (PTM). In the present study we have performed global analysis of lysine methylation of proteins in asexual blood stages of Plasmodium falciparum development. We immunoprecipitated stage specific Plasmodium lysates using anti-methyl lysine specific antibodies that immunostained the asexual blood stage parasites. Using liquid chromatography and tandem mass spectrometry analysis, 570 lysine methylated proteins at three different blood stages were identified. Analysis of the peptide sequences identified 605 methylated sites within 422 proteins. Functional classification of the methylated proteins revealed that the proteins are mainly involved in nucleotide metabolic processes, chromatin organization, transport, homeostatic processes and protein folding. The motif analysis of the methylated lysine peptides reveals novel motifs. Many of the identified lysine methylated proteins are also interacting partners/substrates of PfSET domain proteins as revealed by STRING database analysis. Our findings suggest that the protein methylation at lysine residues is widespread in Plasmodium and plays an important regulatory role in diverse set of the parasite pathways.
Tomaszewski, Maciej; White, Christobelle; Patel, Prashanth; Masca, Nicholas; Damani, Ravi; Hepworth, Joanne; Samani, Nilesh J; Gupta, Pankaj; Madira, Webster; Stanley, Adrian; Williams, Bryan
2014-01-01
Objectives Non-adherence to therapy is an important cause of suboptimal blood pressure control but few practical tools exist to accurately and routinely detect it. We used a simple urine-based assay to evaluate the prevalence of antihypertensive treatment non-adherence and its impact on blood pressure in a specialist hypertension centre. Methods 208 hypertensive patients (125 new referrals, 66 follow-up patients with inadequate blood pressure control and 17 renal denervation referrals) underwent assessment of antihypertensive drug intake using high-performance liquid chromatography-tandem mass spectrometry (HP LC-MS/MS) urine analysis at the time of clinical appointment. A total of 40 most commonly prescribed antihypertensive medications (or their metabolites) were screened for in spot urine samples. Results Overall, 25% of patients were totally or partially non-adherent to antihypertensive treatment (total non-adherence 10.1%, partial non-adherence 14.9%). The highest prevalence of partial and total non-adherence was among follow-up patients with inadequate blood pressure control (28.8%) and those referred for consideration of renal denervation (23.5%), respectively. There was a linear relationship between blood pressure and the numerical difference in detected/prescribed antihypertensive medications—every unit increase in this difference was associated with 3.0 (1.1) mm Hg, 3.1 (0.7) mm Hg and 1.9 (0.7) mm Hg increase in adjusted clinic systolic blood pressure, clinic diastolic blood pressure (DBP) and 24 h mean daytime DBP (p=0.0051, p=8.62×10−6, p=0.0057), respectively. Conclusions Non-adherence to blood pressure lowering therapy is common, particularly in patients with suboptimal blood pressure control and those referred for renal denervation. HP LC-MS/MS urine analysis could be used to exclude non-adherence and better stratify further investigations and intervention. PMID:24694797
Meng, Yutong; Li, Zhirui; Gong, Ke; An, Xiao; Dong, Jiyuan; Tang, Peifu
2018-01-01
Obesity can result in increased blood loss, which is correlated with poor prognosis in total knee arthroplasty (TKA). Clinical application of tranexamic acid is effective in reducing blood loss in TKA. However, most previous studies focused on the effect of tranexamic acid in the whole population, neglecting patients with specific health conditions, such as obesity. We hypothesized that tranexamic acid would reduce blood loss to a greater extent in obese patients than in those of normal weight. A total of 304 patients with knee osteoarthritis treated with TKA from October 2013 to March 2015 were separated into tranexamic, non-tranexamic, obese, and non-obese groups. The demographic characteristics, surgical indices, and hematological indices were all recorded. We first investigated the ability of intravenous tranexamic acid to reduce intraoperative blood loss in knee osteoarthritis patients undergoing unilateral TKA. Second, we performed subgroup analysis to compare the effects of tranexamic acid between obese and non-obese patients separately. Of the 304 patients, 146 (52.0%) received tranexamic acid and 130 (42.8%) were obese. In the analysis of the whole group, both the actual and occult blood loss volume were lower in the tranexamic acid group (both P < 0.05). Tourniquet time was shorter in the tranexamic acid group ( P < 0.05). In subgroup analysis, tranexamic acid was shown to reduce theoretical and actual blood loss in both the obese and non-obese groups ( P < 0.05). Tranexamic acid reduced occult blood loss and tourniquet time in the obese group ( P < 0.05), while no such effects were observed in the non-obese group ( P > 0.05). Tranexamic acid can reduce occult blood loss and tourniquet time in obese patients to a greater extent than in patients of normal weight. Therefore, obese knee osteoarthritis patients undergoing TKA can benefit more from tranexamic acid.
Gong, Ke; An, Xiao; Dong, Jiyuan; Tang, Peifu
2018-01-01
Purpose Obesity can result in increased blood loss, which is correlated with poor prognosis in total knee arthroplasty (TKA). Clinical application of tranexamic acid is effective in reducing blood loss in TKA. However, most previous studies focused on the effect of tranexamic acid in the whole population, neglecting patients with specific health conditions, such as obesity. We hypothesized that tranexamic acid would reduce blood loss to a greater extent in obese patients than in those of normal weight. Patients and methods A total of 304 patients with knee osteoarthritis treated with TKA from October 2013 to March 2015 were separated into tranexamic, non-tranexamic, obese, and non-obese groups. The demographic characteristics, surgical indices, and hematological indices were all recorded. We first investigated the ability of intravenous tranexamic acid to reduce intraoperative blood loss in knee osteoarthritis patients undergoing unilateral TKA. Second, we performed subgroup analysis to compare the effects of tranexamic acid between obese and non-obese patients separately. Results Of the 304 patients, 146 (52.0%) received tranexamic acid and 130 (42.8%) were obese. In the analysis of the whole group, both the actual and occult blood loss volume were lower in the tranexamic acid group (both P < 0.05). Tourniquet time was shorter in the tranexamic acid group (P < 0.05). In subgroup analysis, tranexamic acid was shown to reduce theoretical and actual blood loss in both the obese and non-obese groups (P < 0.05). Tranexamic acid reduced occult blood loss and tourniquet time in the obese group (P < 0.05), while no such effects were observed in the non-obese group (P > 0.05). Conclusion Tranexamic acid can reduce occult blood loss and tourniquet time in obese patients to a greater extent than in patients of normal weight. Therefore, obese knee osteoarthritis patients undergoing TKA can benefit more from tranexamic acid. PMID:29695912
High-speed video analysis of forward and backward spattered blood droplets
NASA Astrophysics Data System (ADS)
Comiskey, Patrick; Yarin, Alexander; Attinger, Daniel
2017-11-01
High-speed videos of blood spatter due to a gunshot taken by the Ames Laboratory Midwest Forensics Resource Center are analyzed. The videos used in this analysis were focused on a variety of targets hit by a bullet which caused either forward, backward, or both types of blood spatter. The analysis process utilized particle image velocimetry and particle analysis software to measure drop velocities as well as the distributions of the number of droplets and their respective side view area. This analysis revealed that forward spatter results in drops travelling twice as fast compared to backward spatter, while both types of spatter contain drops of approximately the same size. Moreover, the close-to-cone domain in which drops are issued is larger in forward spatter than in the backward one. The inclination angle of the bullet as it penetrates the target is seen to play a significant role in the directional preference of the spattered blood. Also, the aerodynamic drop-drop interaction, muzzle gases, bullet impact angle, as well as the aerodynamic wake of the bullet are seen to greatly influence the flight of the drops. The aim of this study is to provide a quantitative basis for current and future research on bloodstain pattern analysis. This work was financially supported by the United States National Institute of Justice (award NIJ 2014-DN-BXK036).
Araki, Yoshihiko; Nonaka, Daisuke; Hamamura, Kensuke; Yanagida, Mitsuaki; Ishikawa, Hitoshi; Banzai, Michio; Maruyama, Mayuko; Endo, Shuichiro; Tajima, Atsushi; Lee, Lyang-Ja; Nojima, Michio; Takamori, Kenji; Yoshida, Koyo; Takeda, Satoru; Tanaka, Kenji
2013-10-01
To date, numerous studies have searched for candidate molecules or clinical examination methods as potential biomarkers for monitoring intractable diseases, such as carcinomas. Evidence accumulated over the past decade shows that many proteolytic peptides appear in human humoral fluids, including peripheral blood, in association with an individual's health condition. Although an analysis of the whole peptide (the 'peptidome') using mass spectrometry is thought to be one of the most powerful and promising experimental approaches, it has failed to identify biomarkers in the clinical blood samples, presumably due to the methodological limitations. In general, commonly used techniques for proteomic analysis of blood require the removal of large amounts of serum/plasma proteins prior to mass spectrometry analysis, and this step seems to have resulted in the overlooking of important biomarkers during the analytical process. Here, we provide a brief overview of a new quantitative peptidomic analysis by a one-step direct transfer technology without depletion of major blood proteins. Using this technology, we herein report experimental data on serum peptidomic analysis for patients with pregnancy-induced hypertension as a clinical model. In addition, we refer to the potential utility of this approach for the monitoring of pathophysiological status in female reproductive system disorders in general. © 2013 The Authors. Journal of Obstetrics and Gynaecology Research © 2013 Japan Society of Obstetrics and Gynecology.
Meyer, Georg F; Spray, Amy; Fairlie, Jo E; Uomini, Natalie T
2014-01-01
Current neuroimaging techniques with high spatial resolution constrain participant motion so that many natural tasks cannot be carried out. The aim of this paper is to show how a time-locked correlation-analysis of cerebral blood flow velocity (CBFV) lateralization data, obtained with functional TransCranial Doppler (fTCD) ultrasound, can be used to infer cerebral activation patterns across tasks. In a first experiment we demonstrate that the proposed analysis method results in data that are comparable with the standard Lateralization Index (LI) for within-task comparisons of CBFV patterns, recorded during cued word generation (CWG) at two difficulty levels. In the main experiment we demonstrate that the proposed analysis method shows correlated blood-flow patterns for two different cognitive tasks that are known to draw on common brain areas, CWG, and Music Synthesis. We show that CBFV patterns for Music and CWG are correlated only for participants with prior musical training. CBFV patterns for tasks that draw on distinct brain areas, the Tower of London and CWG, are not correlated. The proposed methodology extends conventional fTCD analysis by including temporal information in the analysis of cerebral blood-flow patterns to provide a robust, non-invasive method to infer whether common brain areas are used in different cognitive tasks. It complements conventional high resolution imaging techniques.
Ried, Karin
2016-02-01
Garlic has been shown to have cardiovascular protective and immunomodulatory properties. We updated a previous meta-analysis on the effect of garlic on blood pressure and reviewed the effect of garlic on cholesterol and immunity. We searched the Medline database for randomized controlled trials (RCTs) published between 1955 and December 2013 on the effect of garlic preparations on blood pressure. In addition, we reviewed the effect of garlic on cholesterol and immunity. Our updated meta-analysis on the effect of garlic on blood pressure, which included 20 trials with 970 participants, showed a mean ± SE decrease in systolic blood pressure (SBP) of 5.1 ± 2.2 mm Hg (P < 0.001) and a mean ± SE decrease in diastolic blood pressure (DBP) of 2.5 ± 1.6 mm Hg (P < 0.002) compared with placebo. Subgroup analysis of trials in hypertensive subjects (SBP/DBP ≥140/90 mm Hg) at baseline revealed a larger significant reduction in SBP of 8.7 ± 2.2 mm Hg (P < 0.001; n = 10) and in DBP of 6.1 ± 1.3 mm Hg (P < 0.001; n = 6). A previously published meta-analysis on the effect of garlic on blood lipids, which included 39 primary RCTs and 2300 adults treated for a minimum of 2 wk, suggested garlic to be effective in reducing total and LDL cholesterol by 10% if taken for >2 mo by individuals with slightly elevated concentrations [e.g., total cholesterol >200 mg/dL (>5.5 mmol/L)]. Garlic has immunomodulating effects by increasing macrophage activity, natural killer cells, and the production of T and B cells. Clinical trials have shown garlic to significantly reduce the number, duration, and severity of upper respiratory infections. Our review suggests that garlic supplements have the potential to lower blood pressure in hypertensive individuals, to regulate slightly elevated cholesterol concentrations, and to stimulate the immune system. Garlic supplements are highly tolerated and may be considered as a complementary treatment option for hypertension, slightly elevated cholesterol, and stimulation of immunity. Future long-term trials are needed to elucidate the effect of garlic on cardiovascular morbidity and mortality. © 2016 American Society for Nutrition.
Microarray characterization of gene expression changes in blood during acute ethanol exposure
2013-01-01
Background As part of the civil aviation safety program to define the adverse effects of ethanol on flying performance, we performed a DNA microarray analysis of human whole blood samples from a five-time point study of subjects administered ethanol orally, followed by breathalyzer analysis, to monitor blood alcohol concentration (BAC) to discover significant gene expression changes in response to the ethanol exposure. Methods Subjects were administered either orange juice or orange juice with ethanol. Blood samples were taken based on BAC and total RNA was isolated from PaxGene™ blood tubes. The amplified cDNA was used in microarray and quantitative real-time polymerase chain reaction (RT-qPCR) analyses to evaluate differential gene expression. Microarray data was analyzed in a pipeline fashion to summarize and normalize and the results evaluated for relative expression across time points with multiple methods. Candidate genes showing distinctive expression patterns in response to ethanol were clustered by pattern and further analyzed for related function, pathway membership and common transcription factor binding within and across clusters. RT-qPCR was used with representative genes to confirm relative transcript levels across time to those detected in microarrays. Results Microarray analysis of samples representing 0%, 0.04%, 0.08%, return to 0.04%, and 0.02% wt/vol BAC showed that changes in gene expression could be detected across the time course. The expression changes were verified by qRT-PCR. The candidate genes of interest (GOI) identified from the microarray analysis and clustered by expression pattern across the five BAC points showed seven coordinately expressed groups. Analysis showed function-based networks, shared transcription factor binding sites and signaling pathways for members of the clusters. These include hematological functions, innate immunity and inflammation functions, metabolic functions expected of ethanol metabolism, and pancreatic and hepatic function. Five of the seven clusters showed links to the p38 MAPK pathway. Conclusions The results of this study provide a first look at changing gene expression patterns in human blood during an acute rise in blood ethanol concentration and its depletion because of metabolism and excretion, and demonstrate that it is possible to detect changes in gene expression using total RNA isolated from whole blood. The analysis approach for this study serves as a workflow to investigate the biology linked to expression changes across a time course and from these changes, to identify target genes that could serve as biomarkers linked to pilot performance. PMID:23883607
Malm, Christer B.; Khoo, Nelson S.; Granlund, Irene; Lindstedt, Emilia; Hult, Andreas
2016-01-01
The discovery of erythropoietin (EPO) simplified blood doping in sports, but improved detection methods, for EPO has forced cheating athletes to return to blood transfusion. Autologous blood transfusion with cryopreserved red blood cells (RBCs) is the method of choice, because no valid method exists to accurately detect such event. In endurance sports, it can be estimated that elite athletes improve performance by up to 3% with blood doping, regardless of method. Valid detection methods for autologous blood doping is important to maintain credibility of athletic performances. Recreational male (N = 27) and female (N = 11) athletes served as Transfusion (N = 28) and Control (N = 10) subjects in two different transfusion settings. Hematological variables and physical performance were measured before donation of 450 or 900 mL whole blood, and until four weeks after re-infusion of the cryopreserved RBC fraction. Blood was analyzed for transferrin, iron, Hb, EVF, MCV, MCHC, reticulocytes, leucocytes and EPO. Repeated measures multivariate analysis of variance (MANOVA) and pattern recognition using Principal Component Analysis (PCA) and Orthogonal Projections of Latent Structures (OPLS) discriminant analysis (DA) investigated differences between Control and Transfusion groups over time. Significant increase in performance (15 ± 8%) and VO2max (17 ± 10%) (mean ± SD) could be measured 48 h after RBC re-infusion, and remained increased for up to four weeks in some subjects. In total, 533 blood samples were included in the study (Clean = 220, Transfused = 313). In response to blood transfusion, the largest change in hematological variables occurred 48 h after blood donation, when Control and Transfused groups could be separated with OPLS-DA (R2 = 0.76/Q2 = 0.59). RBC re-infusion resulted in the best model (R2 = 0.40/Q2 = 0.10) at the first sampling point (48 h), predicting one false positive and one false negative. Over all, a 25% and 86% false positives ratio was achieved in two separate trials. In conclusions, autologous re-infusion of RBCs increased VO2max and performance as hypothesized, but hematological profiling by multivariate statistics could not reach the WADA stipulated false positive ratio of <0.001% at any time point investigated. A majority of samples remained within limits of normal individual variation at all times. PMID:27284981
Automatic analysis of microscopic images of red blood cell aggregates
NASA Astrophysics Data System (ADS)
Menichini, Pablo A.; Larese, Mónica G.; Riquelme, Bibiana D.
2015-06-01
Red blood cell aggregation is one of the most important factors in blood viscosity at stasis or at very low rates of flow. The basic structure of aggregates is a linear array of cell commonly termed as rouleaux. Enhanced or abnormal aggregation is seen in clinical conditions, such as diabetes and hypertension, producing alterations in the microcirculation, some of which can be analyzed through the characterization of aggregated cells. Frequently, image processing and analysis for the characterization of RBC aggregation were done manually or semi-automatically using interactive tools. We propose a system that processes images of RBC aggregation and automatically obtains the characterization and quantification of the different types of RBC aggregates. Present technique could be interesting to perform the adaptation as a routine used in hemorheological and Clinical Biochemistry Laboratories because this automatic method is rapid, efficient and economical, and at the same time independent of the user performing the analysis (repeatability of the analysis).
Mintzer, Jonathan P; Parvez, Boriana; La Gamma, Edmund F
2015-11-01
To evaluate the magnitude, consistency, and natural history of reductions in cerebral regional tissue oxygenation (CrSO2) during umbilical arterial (UA) blood sampling in very low birth weight neonates. Data were collected during a prospective observational near-infrared spectroscopy survey conducted on a convenience sample of 500-1250 g neonates during the first 10 postnatal days. A before-after analysis of UA blood sampling effects on CrSO2 absolute values and variability was performed. The present analysis was not designed a priori and was conducted following the bedside observation of CrSO2 decrements contiguous with UA blood draws. Fifteen very low birth weight neonates had 201 UA blood draws. Baseline CrSO2 (mean ± SEM) decreased following UA blood sampling, from 70 ± 1% to a nadir of 63 ± 1% (P < .001) occurring 4 ± 3 (range 2-24) minutes following blood draws. CrSO2 subsequently increased to 70 ± 1% (P < .001 compared with nadir) at 10 ± 4 (range 4-28) minutes following UA blood sampling. Coefficients of variation (mean ± SEM) increased from 0.02 ± 0.001 at baseline to 0.05 ± 0.004 (P < .001), followed by a decrease to 0.03 ± 0.003 (P < .001 for all comparisons), thus denoting increased CrSO2 variability following UA blood sampling. UA blood sampling is associated with significant CrSO2 decrements with increased variability over clinically significant intervals. Whether these changes impact complications of prematurity, including intraventricular hemorrhage and periventricular leukomalacia, remain unknown. Copyright © 2015 Elsevier Inc. All rights reserved.
Associations between ABO blood groups and biochemical recurrence after radical prostatectomy.
Ohno, Yoshio; Ohori, Makoto; Nakashima, Jun; Okubo, Hidenori; Satake, Naoya; Takizawa, Issei; Hashimoto, Takeshi; Hamada, Riu; Nakagami, Yoshihiro; Yoshioka, Kunihiko; Tachibana, Masaaki
2015-01-01
Recent studies have demonstrated associations between ABO blood groups and prognosis in various types of cancers. The aim of this study was to investigate the association between ABO blood groups and biochemical recurrence (BCR) after radical prostatectomy (RP). A total of 555 patients with prostate cancer who underwent RP were included in the study. No patients received neoadjuvant and/or adjuvant therapy. The effect of ABO blood groups on BCR was examined using univariate and multivariate analyses. During the follow-up period (mean, 52.0 months), 166 patients (29.9%) experienced BCR, with a 5-year BCR-free rate of 67.3%. Although the ABO blood group was not a significantly associated with BCR in the univariate analysis, it was an independent predictor of BCR in the multivariate analysis: blood type O patients had a significantly lower risk of BCR compared to type A patients (Hazard ratio, 0.608; 95% confidence interval, 0.410-0.902; P = 0.014). Further analyses revealed that surgical margin status confounded the assessment of the association between the ABO blood group and BCR. In the analyses of patients with a negative surgical margin, the 5-year BCR-free rate in blood type O patients was a significantly higher than that in type A patients (91.2% vs. 71.0%; P = 0.026). Blood type O is significantly associated with a decreased risk of biochemical recurrence after radical prostatectomy. Further studies are needed to clarify the nature of this association.
Mitsumata, Kaneto; Saitoh, Shigeyuki; Ohnishi, Hirofumi; Akasaka, Hiroshi; Miura, Tetsuji
2012-11-01
The mechanism underlying the association of parental hypertension with cardiovascular events in offspring remains unclear. In this study, the effects of parental hypertension on longitudinal trends of blood pressure and metabolic parameters were examined by mixed-effects model analysis. From 1977 to 2006, 5198 subjects participated in the Tanno-Sobetsu Study, and we selected 2607 subjects (1095 men and 1512 women) for whom data on parental history of hypertension were available. In both men and women with and without parental hypertension, systolic blood pressure and fasting blood glucose levels consistently increased from the third to eighth decades of life, whereas diastolic blood pressure and serum triglyceride levels followed biphasic (inverted U shape) time courses during that period. However, the relationships between the parameters and age were significantly shifted upward (by ≈5.3 mm Hg in systolic blood pressure, 2.8 mm Hg in diastolic blood pressure, 0.30 mmol/L in blood glucose, and 0.09 mmol/L in triglyceride) in the group with parental hypertension compared with those in the group without parental hypertension. Both paternal and maternal histories of hypertension were determinants of systolic blood pressure and diastolic blood pressure, and there was no significant interaction between the sides of parental history. There were no significant effects of parental hypertension on age-dependent or body mass index-dependent changes in serum low-density lipoprotein cholesterol or high-density lipoprotein cholesterol level. The present results indicate that parental hypertension has an age-independent impact on elevation of blood pressure, plasma glucose, and triglyceride levels, which may underlie the reported increase in cardiovascular events by family history of hypertension.
Peeters, Bart; Geerts, Inge; Van Mullem, Mia; Micalessi, Isabel; Saegeman, Veroniek; Moerman, Jan
2016-05-01
Many hospitals opt for early postnatal discharge of newborns with a potential risk of readmission for neonatal hyperbilirubinemia. Assays/algorithms with the possibility to improve prediction of significant neonatal hyperbilirubinemia are needed to optimize screening protocols and safe discharge of neonates. This study investigated the predictive value of umbilical cord blood (UCB) testing for significant hyperbilirubinemia. Neonatal UCB bilirubin, UCB direct antiglobulin test (DAT), and blood group were determined, as well as the maternal blood group and the red blood cell antibody status. Moreover, in newborns with clinically apparent jaundice after visual assessment, plasma total bilirubin (TB) was measured. Clinical factors positively associated with UCB bilirubin were ABO incompatibility, positive DAT, presence of maternal red cell antibodies, alarming visual assessment and significant hyperbilirubinemia in the first 6 days of life. UCB bilirubin performed clinically well with an area under the receiver-operating characteristic curve (AUC) of 0.82 (95 % CI 0.80-0.84). The combined UCB bilirubin, DAT, and blood group analysis outperformed results of these parameters considered separately to detect significant hyperbilirubinemia and correlated exponentially with hyperbilirubinemia post-test probability. Post-test probabilities for neonatal hyperbilirubinemia can be calculated using exponential functions defined by UCB bilirubin, DAT, and ABO compatibility results. • The diagnostic value of the triad umbilical cord blood bilirubin measurement, direct antiglobulin testing and blood group analysis for neonatal hyperbilirubinemia remains unclear in literature. • Currently no guideline recommends screening for hyperbilirubinemia using umbilical cord blood. What is New: • Post-test probability for hyperbilirubinemia correlated exponentially with umbilical cord blood bilirubin in different risk groups defined by direct antiglobulin test and ABO blood group compatibility results. • Exponential functions can be used to calculate hyperbilirubinemia probability.
Jin, Ling; Escher, Beate I; Limpus, Colin J; Gaus, Caroline
2015-11-01
Conventional target analysis of biological samples such as blood limits our ability to understand mixture effects of chemicals. This study aimed to establish a rapid passive sampling technique using the polymer polydimethylsiloxane (PDMS) for exhaustive extraction of mixtures of neutral organic chemicals accumulated in blood of green turtles, in preparation for screening in in vitro bioassays. We designed a PDMS-blood partitioning system based on the partition coefficients of chemicals between PDMS and major blood components. The sampling kinetics of hydrophobic test chemicals (polychlorinated dibenzo-p-dioxins; PCDDs) from blood into PDMS were reasonably fast reaching steady state in <96 h. The geometric mean of the measured PDMS-blood partition coefficients for PCDDs, polychlorinated biphenyls (PCBs) and polybrominated diphenyl ethers (PBDEs) was 14 L blood kg PDMS(-1) and showed little variability (95% confidence interval from 8.4 to 29) across a wide range of hydrophobicity (logKow 5.7-8.3). The mass transfer of these chemicals from 5 mL blood into 0.94 g PDMS was 62-84%, which is similar to analytical recoveries in conventional solvent extraction methods. The validated method was applied to 15 blood samples from green turtles with known concentrations of PCDD/Fs, dioxin-like PCBs, PBDEs and organochlorine pesticides. The quantified chemicals explained most of the dioxin-like activity (69-98%), but less than 0.4% of the oxidative stress response. The results demonstrate the applicability of PDMS-based passive sampling to extract bioaccumulative chemicals from blood as well as the value of in vitro bioassays for capturing the combined effects of unknown and known chemicals. Copyright © 2015 Elsevier Ltd. All rights reserved.
Makovický, Peter; Matlach, Radek; Pokorná, Olga; Mošna, František; Makovický, Pavol
2015-01-01
The bloodstain pattern analysis (BPA) is useful in the forensic medicine. In Czechoslovakian criminology is this method not commonly used. The objective of this work is to calculate the impact length, height and distance splashing of blood drops. The results are compared with the real values for specific cases. It is also compared to calculate the angle of incidence of blood drops, using sinα with a form using tgα. For this purposes we used two different character cases from practice with well-preserved condition and readable blood stains. Selected blood stains were documented in order to calculate the angle of incidence of blood drops and to calculateorigin splashes. For this drop of blood, the distance of impact of the drops of blood (x), the height of the sprayed blood drops (y) and the length of the flight path the drop of blood (l). The obtained data was retrospectively analysed for the two models. The first straight line is represented by the triangle (M1) and the other is the parabolic model (M2). The formulae were derived using the Euler substitution. The results show that the angle of incidence of the drop of blood can be calculated as sinα and the tgα. When applying, the triangle is appropriate to consider the application and sinα parabolic requires the calculation of the angle of incidence drops of blood tgα. Parabola is useful for the BPA. In Czechoslovakian should be providing workplace training seminars BPA primarily intended for forensic investigators.We recommend the use of this method during investigations, verification of acts in forensic practice.
USDA-ARS?s Scientific Manuscript database
Species composition, activity patterns and blood meal analysis of sand fly populations were investigated in the metropolitan region of Thessaloniki, North Greece from May to October 2011. Sampling was conducted weekly in 3 different environments (animal facilities, open fields, residential areas) al...
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It provide...
The purpose of this SOP is to describe collection, storage, and shipment requirements of blood samples for metal, pesticide, polynuclear aromatic hydrocarbons (PAHs), volatile organic compound (VOC), and lipid analysis. Seven samples were taken from a single puncture: two 3-mL t...
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). It pro...
Laser speckle imaging of rat retinal blood flow with hybrid temporal and spatial analysis method
NASA Astrophysics Data System (ADS)
Cheng, Haiying; Yan, Yumei; Duong, Timothy Q.
2009-02-01
Noninvasive monitoring of blood flow in retinal circulation will reveal the progression and treatment of ocular disorders, such as diabetic retinopathy, age-related macular degeneration and glaucoma. A non-invasive and direct BF measurement technique with high spatial-temporal resolution is needed for retinal imaging. Laser speckle imaging (LSI) is such a method. Currently, there are two analysis methods for LSI: spatial statistics LSI (SS-LSI) and temporal statistical LSI (TS-LSI). Comparing these two analysis methods, SS-LSI has higher signal to noise ratio (SNR) and TSLSI is less susceptible to artifacts from stationary speckle. We proposed a hybrid temporal and spatial analysis method (HTS-LSI) to measure the retinal blood flow. Gas challenge experiment was performed and images were analyzed by HTS-LSI. Results showed that HTS-LSI can not only remove the stationary speckle but also increase the SNR. Under 100% O2, retinal BF decreased by 20-30%. This was consistent with the results observed with laser Doppler technique. As retinal blood flow is a critical physiological parameter and its perturbation has been implicated in the early stages of many retinal diseases, HTS-LSI will be an efficient method in early detection of retina diseases.
Sumbu, B M M; Longo-Mbenza, B; Ahuka-Mundeke, S; Muwonga, J M; Mvumbi-Lelo, G; Maphana, H M; Kayembe Nzongola-Nkasu, D; Kalumbu, F M
2018-02-01
The screening of anti-Human Immunodeficiency Virus antibodies is mandatory in every blood donor admitted to the Blood Bank of Kinshasa University Clinics since 1984. However, no compiled data are available to date. The objective of this study was to establish the trend, prevalence, viral co-infections, and determinants of Human Immunodeficiency anti-Virus serology in blood donors admitted between 2003-2006 and 2008-2013. A retrospective analysis was carried out at University Kinshasa Clinics, using blood donors' records during 2003-2006 and 2008-2013. The prevalence of the human immunodeficiency virus per year, age, sex and type of blood donors were estimated. Independent predictors of human immunodeficiency virus seropositivity were also identified. Out of 26,341 blood donors, 2.2% (n=576/26,341) were seropositive for Human Immunodeficiency Virus. Age<25 years (OR=1.7; 95% CI: 1.4-2; P<0.0001) and Hepatitis C virus seropositivity (OR=3; 95% CI; 1.8-4.9; P<0.001) emerged as independent predictors of Human Immunodeficiency Virus seropositivity. This study shows a strong association between the Human Immunodeficiency Virus and hepatitis C and younger age respectively. Further studies are needed to ensure safety of Blood donation in Democratic Republic of Congo. Copyright © 2017 Elsevier Masson SAS. All rights reserved.
Nirogi, Ramakrishna; Ajjala, Devender Reddy; Kandikere, Vishwottam; Aleti, Raghupathi; Srikakolapu, SuryaRao; Vurimindi, Himabindu
2012-10-15
Deferasirox is an iron chelating agent for the treatment of transfusional iron over load in patients with chronic anemia. These anemic patients require close monitoring of the deferasirox exposures for ensuring its therapeutic efficacy. Dried blood spot (DBS) sampling methodology has the advantages of low volume of blood withdrawal and ease of transportation and storage over liquid blood methods. A LC-MS/MS based analytical method was developed using reversed phase column with gradient elution program and quantitated in MRM mode. Linearity range for the liquid blood was 1-1000 ng/mL and for DBS was 5-5000 ng/mL under similar mass spectrometry conditions. The method was validated with respective (M-H)(-) ions, m/z 372→118 for deferasirox and m/z 410→348 for fluvastatin (internal standard). The validated method was applied for the analysis of DBS samples from a rat pharmacokinetic study and results were compared against liquid blood samples from the same animal. The mean C(max) from DBS sample (1121 ng/mL) was comparable to mean C(max) found in blood samples (1015 ng/mL) at 2h after oral dose of deferasirox. All the other calculated pharmacokinetic parameters were quite comparable for both liquid blood and DBS samples. Copyright © 2012. Published by Elsevier B.V.
Lee, Hye Ryun; Park, Jeong Su; Shin, Sue; Roh, Eun Youn; Yoon, Jong Hyun; Han, Kyou Sup; Kim, Byung Jae; Storms, Robert W; Chao, Nelson J
2012-01-01
We analyzed neonatal factors that could affect hematopoietic variables of cord blood (CB) donated from Korean neonates. The numbers of total nucleated cells (TNCs), CD34+ cells, and CD34+ cells/TNCs of CB in neonates were compared according to sex, gestational age, birth weight, birth weight centile for gestational age, and ABO blood group. With 11,098 CB units analyzed, blood group O CB showed an increased number of TNCs, CD34+ cells, and CD34+ cells/TNCs compared with other blood groups. Although TNC counts were lower in males, no difference in the number of CD34+ cells was demonstrated because the number of CD34+ cells/TNCs was higher in males. An increase in the gestational age resulted in an increase in the number of TNCs and decreases in the number of CD34+ cells and CD34+ cells/TNCs. The numbers of TNCs, CD34+ cells, and CD34+ cells/TNCs increased according to increased birth weight centile as well as birth weight. CB with blood group O has unique hematologic variables in this large-scale analysis of Korean neonates, although the impact on the storage policies of CB banks or the clinical outcome of transplantation remains to be determined. © 2011 American Association of Blood Banks.
BOLD delay times using group delay in sickle cell disease
NASA Astrophysics Data System (ADS)
Coloigner, Julie; Vu, Chau; Bush, Adam; Borzage, Matt; Rajagopalan, Vidya; Lepore, Natasha; Wood, John
2016-03-01
Sickle cell disease (SCD) is an inherited blood disorder that effects red blood cells, which can lead to vasoocclusion, ischemia and infarct. This disease often results in neurological damage and strokes, leading to morbidity and mortality. Functional Magnetic Resonance Imaging (fMRI) is a non-invasive technique for measuring and mapping the brain activity. Blood Oxygenation Level-Dependent (BOLD) signals contain also information about the neurovascular coupling, vascular reactivity, oxygenation and blood propagation. Temporal relationship between BOLD fluctuations in different parts of the brain provides also a mean to investigate the blood delay information. We used the induced desaturation as a label to profile transit times through different brain areas, reflecting oxygen utilization of tissue. In this study, we aimed to compare blood flow propagation delay times between these patients and healthy subjects in areas vascularized by anterior, middle and posterior cerebral arteries. In a group comparison analysis with control subjects, BOLD changes in these areas were found to be almost simultaneous and shorter in the SCD patients, because of their increased brain blood flow. Secondly, the analysis of a patient with a stenosis on the anterior cerebral artery indicated that signal of the area vascularized by this artery lagged the MCA signal. These findings suggest that sickle cell disease causes blood propagation modifications, and that these changes could be used as a biomarker of vascular damage.
Traynor, Damien; Duraipandian, Shiyamala; Martin, Cara M; O'Leary, John J; Lyng, Fiona M
2018-05-01
There is an unmet need for methods to help in the early detection of cervical precancer. Optical spectroscopy-based techniques, such as Raman spectroscopy, have shown great potential for diagnosis of different cancers, including cervical cancer. However, relatively few studies have been carried out on liquid-based cytology (LBC) pap test specimens and confounding factors, such as blood contamination, have been identified. Previous work reported a method to remove blood contamination before Raman spectroscopy by pretreatment of the slides with hydrogen peroxide. The aim of the present study was to extend this work to excessively bloody samples to see if these could be rendered suitable for Raman spectroscopy. LBC ThinPrep specimens were treated by adding hydrogen peroxide directly to the vial before slide preparation. Good quality Raman spectra were recorded from negative and high grade (HG) cytology samples with no blood contamination and with heavy blood contamination. Good classification between negative and HG cytology could be achieved for samples with no blood contamination (sensitivity 92%, specificity 93%) and heavy blood contamination (sensitivity 89%, specificity 88%) with poorer classification when samples were combined (sensitivity 82%, specificity 87%). This study demonstrates for the first time the improved potential of Raman spectroscopy for analysis of ThinPrep specimens regardless of blood contamination. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Mitrovic, Nikola; Delic, Dragan; Markovic-Denic, Ljiljana; Jovicic, Milica; Popovic, Natasa; Bojovic, Ksenija; Simonovic Babic, Jasmina; Svirtlih, Neda
2015-07-01
The epidemiological characteristics of hepatitis C virus (HCV) infection have not yet been described in Serbia. To determine the prevalence of anti-HCV-positive individuals among first-time blood donors and the risk factors for hepatitis C transmission. A multicentre case-control study nested within a prospective cohort study was conducted at 10 main transfusion centres in Serbia in 2013 and 27,160 blood donors who gave blood for the first time were included. Blood donors with confirmed anti-HCV positivity and seronegative controls were enrolled to determine the risk factors. Of 27,160 blood donors 52 were anti-HCV-positive; seroprevalence was 0.19%. By univariate analysis, marital status, educational level, drug use, previous transfusion, tattooing, non-use of condoms and number of sexual partners, were risk factors for hepatitis C. In the final multivariate analysis, three factors remained independently predictive: drug use, tattooing and previous blood transfusion. In total, 87.5% of cases had at least one of the risk factors for HCV transmission; 20.9% presumed that they knew when the infection occurred. HCV seroprevalence in Serbia is higher than in developed European countries. Preventive measures need to be directed towards drug use and tattooing facilities. The admission questionnaire for blood donors should be improved. Copyright © 2015 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
A change in paradigm: lowering blood pressure in everyone over a certain age.
Law, Malcolm
2012-06-01
Dividing people into 'hypertensives' and 'normotensives' is commonplace but problematic. The relationship between blood pressure and cardiovascular disease is continuous. The Prospective Studies Collaboration analysis shows a continuous straight line dose-response relationship across the entire population down to blood pressure levels of 115 mmHg systolic and 75 mmHg diastolic, the confidence limits on the individual data points being sufficiently narrow to exclude even a minor deviation from a linear relationship. Meta-analysis of randomized controlled trials shows that blood pressure-lowering drugs produce similar proportional reductions in risk of coronary heart disease (CHD) and stroke irrespective of pre-treatment blood pressure, down to levels of 110 mmHg systolic and 70 mmHg diastolic. There are also now sufficient trial data to show a statistically significant risk reduction in 'normotensive' people without known vascular disease on entry. The straight line (log-linear) relationship means that the benefit derived from lowering blood pressure is proportional to existing risk, so the decision on whom to treat with blood pressure-lowering drugs should depend on a person's overall absolute risk irrespective of blood pressure. In primary prevention, basing treatment on age alone rather than overall absolute risk entails little loss of efficacy and may be preferred on the basis of simplicity and avoidance of anxiety in telling people they are at elevated risk.
Carrol, Enitan D; Salway, Fiona; Pepper, Stuart D; Saunders, Emma; Mankhambo, Limangeni A; Ollier, William E; Hart, C Anthony; Day, Phillip
2007-01-01
Background The challenge of gene expression studies is to reliably quantify levels of transcripts, but this is hindered by a number of factors including sample availability, handling and storage. The PAXgene™ Blood RNA System includes a stabilizing additive in a plastic evacuated tube, but requires 2.5 mL blood, which makes routine implementation impractical for paediatric use. The aim of this study was to modify the PAXgene™ Blood RNA System kit protocol for application to small, sick chidren, without compromising RNA integrity, and subsequently to perform quantitative analysis of ICAM and interleukin-6 gene expression. Aliquots of 0.86 mL PAXgene™ reagent were put into microtubes and 0.3 mL whole blood added to maintain the same recommended proportions as in the PAXgene™ evacuated tube system. RNA quality was assessed using the Agilent BioAnalyser 2100 and an in-house TaqMan™ assay which measures GAPDH transcript integrity by determining 3' to 5' ratios. qPCR analysis was performed on an additional panel of 7 housekeeping genes. Three reference genes (HPRT1, YWHAZ and GAPDH) were identified using the GeNORM algorithm, which were subsequently used to normalising target gene expression levels. ICAM-1 and IL-6 gene expression were measured in 87 Malawian children with invasive pneumococcal disease. Results Total RNA yield was between 1,114 and 2,950 ng and the BioAnalyser 2100 demonstrated discernible 18s and 28s bands. The cycle threshold values obtained for the seven housekeeping genes were between 15 and 30 and showed good consistency. Median relative ICAM and IL-6 gene expression were significantly reduced in non-survivors compared to survivors (ICAM: 3.56 vs 4.41, p = 0.04, and IL-6: 2.16 vs 6.73, p = 0.02). Conclusion We have successfully modified the PAXgene™ blood collection system for use in small children and demonstrated preservation of RNA integrity and successful quantitative real-time PCR analysis. PMID:17850649
Wang, Fenglei; Zheng, Jusheng; Yang, Bo; Jiang, Jiajing; Fu, Yuanqing; Li, Duo
2015-10-27
Vegetarian diets exclude all animal flesh and are being widely adopted by an increasing number of people; however, effects on blood lipid concentrations remain unclear. This meta-analysis aimed to quantitatively assess the overall effects of vegetarian diets on blood lipids. We searched PubMed, Scopus, Embase, ISI Web of Knowledge, and the Cochrane Library through March 2015. Studies were included if they described the effectiveness of vegetarian diets on blood lipids (total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and triglyceride). Weighted mean effect sizes were calculated for net changes by using a random-effects model. We performed subgroup and univariate meta-regression analyses to explore sources of heterogeneity. Eleven trials were included in the meta-analysis. Vegetarian diets significantly lowered blood concentrations of total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and non-high-density lipoprotein cholesterol, and the pooled estimated changes were -0.36 mmol/L (95% CI -0.55 to -0.17; P<0.001), -0.34 mmol/L (95% CI -0.57 to -0.11; P<0.001), -0.10 mmol/L (95% CI -0.14 to -0.06; P<0.001), and -0.30 mmol/L (95% CI -0.50 to -0.10; P=0.04), respectively. Vegetarian diets did not significantly affect blood triglyceride concentrations, with a pooled estimated mean difference of 0.04 mmol/L (95% CI -0.05 to 0.13; P=0.40). This systematic review and meta-analysis provides evidence that vegetarian diets effectively lower blood concentrations of total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, and non-high-density lipoprotein cholesterol. Such diets could be a useful nonpharmaceutical means of managing dyslipidemia, especially hypercholesterolemia. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.
Schoeman, Elizna M; Lopez, Genghis H; McGowan, Eunike C; Millard, Glenda M; O'Brien, Helen; Roulis, Eileen V; Liew, Yew-Wah; Martin, Jacqueline R; McGrath, Kelli A; Powley, Tanya; Flower, Robert L; Hyland, Catherine A
2017-04-01
Blood group single nucleotide polymorphism genotyping probes for a limited range of polymorphisms. This study investigated whether massively parallel sequencing (also known as next-generation sequencing), with a targeted exome strategy, provides an extended blood group genotype and the extent to which massively parallel sequencing correctly genotypes in homologous gene systems, such as RH and MNS. Donor samples (n = 28) that were extensively phenotyped and genotyped using single nucleotide polymorphism typing, were analyzed using the TruSight One Sequencing Panel and MiSeq platform. Genes for 28 protein-based blood group systems, GATA1, and KLF1 were analyzed. Copy number variation analysis was used to characterize complex structural variants in the GYPC and RH systems. The average sequencing depth per target region was 66.2 ± 39.8. Each sample harbored on average 43 ± 9 variants, of which 10 ± 3 were used for genotyping. For the 28 samples, massively parallel sequencing variant sequences correctly matched expected sequences based on single nucleotide polymorphism genotyping data. Copy number variation analysis defined the Rh C/c alleles and complex RHD hybrids. Hybrid RHD*D-CE-D variants were correctly identified, but copy number variation analysis did not confidently distinguish between D and CE exon deletion versus rearrangement. The targeted exome sequencing strategy employed extended the range of blood group genotypes detected compared with single nucleotide polymorphism typing. This single-test format included detection of complex MNS hybrid cases and, with copy number variation analysis, defined RH hybrid genes along with the RHCE*C allele hitherto difficult to resolve by variant detection. The approach is economical compared with whole-genome sequencing and is suitable for a red blood cell reference laboratory setting. © 2017 AABB.
Blood compatibility of magnesium and its alloys.
Feyerabend, Frank; Wendel, Hans-Peter; Mihailova, Boriana; Heidrich, Stefanie; Agha, Nezha Ahmad; Bismayer, Ulrich; Willumeit-Römer, Regine
2015-10-01
Blood compatibility analysis in the field of biomaterials is a highly controversial topic. Especially for degradable materials like magnesium and its alloys no established test methods are available. The purpose of this study was to apply advanced test methodology for the analysis of degrading materials to get a mechanistic insight into the corrosion process in contact with human blood and plasma. Pure magnesium and two magnesium alloys were analysed in a modified Chandler-Loop setup. Standard clinical parameters were determined, and a thorough analysis of the resulting implant surface chemistry was performed. The contact of the materials to blood evoked an accelerated inflammatory and cell-induced osteoconductive reaction. Corrosion products formed indicate a more realistic, in vivo like situation. The active regulation of corrosion mechanisms of magnesium alloys by different cell types should be more in the focus of research to bridge the gap between in vitro and in vivo observations and to understand the mechanism of action. This in turn could lead to a better acceptance of these materials for implant applications. The presented study deals with the first mechanistic insights during whole human blood contact and its influence on a degrading magnesium-based biomaterial. The combination of clinical parameters and corrosion layer analysis has been performed for the first time. It could be of interest due to the intended use of magnesium-based stents and for orthopaedic applications for clinical applications. An interest for the readers of Acta Biomaterialia may be given, as one of the first clinically approved magnesium-based devices is a wound-closure device, which is in direct contact with blood. Moreover, for orthopaedic applications also blood contact is of high interest. Although this is not the focus of the manuscript, it could help to rise awareness for potential future applications. Copyright © 2015 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bisdas, Sotirios; Konstantinou, George N.; Sherng Lee, Puor; Thng, Choon Hua; Wagenblast, Jens; Baghi, Mehran; San Koh, Tong
2007-10-01
The objective of this work was to evaluate the feasibility of a two-compartment distributed-parameter (DP) tracer kinetic model to generate functional images of several physiologic parameters from dynamic contrast-enhanced CT data obtained of patients with extracranial head and neck tumors and to compare the DP functional images to those obtained by deconvolution-based DCE-CT data analysis. We performed post-processing of DCE-CT studies, obtained from 15 patients with benign and malignant head and neck cancer. We introduced a DP model of the impulse residue function for a capillary-tissue exchange unit, which accounts for the processes of convective transport and capillary-tissue exchange. The calculated parametric maps represented blood flow (F), intravascular blood volume (v1), extravascular extracellular blood volume (v2), vascular transit time (t1), permeability-surface area product (PS), transfer ratios k12 and k21, and the fraction of extracted tracer (E). Based on the same regions of interest (ROI) analysis, we calculated the tumor blood flow (BF), blood volume (BV) and mean transit time (MTT) by using a modified deconvolution-based analysis taking into account the extravasation of the contrast agent for PS imaging. We compared the corresponding values by using Bland-Altman plot analysis. We outlined 73 ROIs including tumor sites, lymph nodes and normal tissue. The Bland-Altman plot analysis revealed that the two methods showed an accepted degree of agreement for blood flow, and, thus, can be used interchangeably for measuring this parameter. Slightly worse agreement was observed between v1 in the DP model and BV but even here the two tracer kinetic analyses can be used interchangeably. Under consideration of whether both techniques may be used interchangeably was the case of t1 and MTT, as well as for measurements of the PS values. The application of the proposed DP model is feasible in the clinical routine and it can be used interchangeably for measuring blood flow and vascular volume with the commercially available reference standard of the deconvolution-based approach. The lack of substantial agreement between the measurements of vascular transit time and permeability-surface area product may be attributed to the different tracer kinetic principles employed by both models and the detailed capillary tissue exchange physiological modeling of the DP technique.
Fernández, María del Mar Ramírez; Wille, Sarah M R; Samyn, Nele; Wood, Michelle; López-Rivadulla, Manuel; De Boeck, Gert
2009-01-01
An automated online solid-phase extraction-liquid chromatography-tandem mass spectrometry (SPE-LC-MS-MS) method for the analysis of amphetamines in blood and urine was developed and validated. Chromatographic separation was achieved on a Nucleodur Sphinx RP column with an LC gradient (a mixture of 10 mM ammonium formate buffer and acetonitrile), ensuring the elution of amphetamine, methamphetamine, MDMA, MDA, MDEA, PMA, and ephedrine within 11 min. The method was fully validated, according to international guidelines, using only 100 and 50 microL of blood and urine, respectively. The method showed an excellent intra- and interassay precision (relative standard deviation < 11.2% and bias < 13%) for two external quality control samples (QC) for both matrices and three and two 'in house' QCs for blood and urine, respectively. Responses were linear over the investigated range (r(2) > 0.99, 2.5-400 microg/L for blood and 25-1000 microg/L for urine). Limits of quantification were determined to be 2.5 and 25 microg/L for blood and urine, respectively. Limits of detection ranged from 0.05 to 0.5 microg/L for blood and 0.25 to 2.5 microg/L for urine, depending on the compound. Furthermore, the analytes and the processed samples were demonstrated to be stable (in the autosampler for at least 72 h and after three freeze/thaw cycles), and no disturbing matrix effects were observed for all compounds. Moreover, no carryover was observed after the analysis of high concentration samples (15,000 microg/L). The method was subsequently applied to authentic blood and urine samples obtained from forensic cases, which covered a broad range of concentrations. The validation results and actual sample analyses demonstrated that this method is rugged, precise, accurate, and well-suited for routine analysis as more than 72 samples are analyzed non-stop in 24 h with minimum sample handling. The combination of the high-throughput online SPE and the well-known sensitivity and selectivity assured by MS-MS resulted in the elimination of the bottleneck associated with the sample preparation requirements and provided increased sensitivity, accuracy, and precision.
Pagano, M B; Metcalf, R A; Hess, J R; Reyes, J; Perkins, J D; Montenovo, M I
2018-04-01
During massive transfusion, the volume ratio of administered plasma (PL Vol) to red blood cell (RBC Vol) appears to be associated with reduced blood utilization and improved survival. The aim of this study was to evaluate the optimal component ratio in the setting of liver transplantation. This is a retrospective chart review of patients who underwent liver transplantation and received at least 500 ml of red blood cells from January 2013 through December 2015. Kernel smoothing analysis determined the proper component ratios to evaluate were a ≥0·85:1 ratio (high) to a ≤0·85:1 ratio (low). Two groups, plasma volume to RBC volume (PL Vol/RBC Vol) and plasma contained in the platelet units added to the plasma calculation [PL + PLT (platelet)] Vol/RBC Vol, were used to evaluate the component ratios. A total of 188 patients were included in the analysis. In the PL Vol/RBC Vol evaluation, a low ratio revealed that 1238 ml (977-1653 ml) (P < 0·0001) and 1178 ml (747-1178) (P < 0·0001) of RBC were used in excess compared to the high ratio, in the univariable and multivariable analysis, respectively. In the PL +PLT Vol/RBC Vol evaluation, a low ratio used 734 ml (193-1275) (P = 0·008) and 886 ml (431-1340) (P < 0·0001) of RBC in excess when compared to high ratio in the univariable and multivariable analysis, respectively. In patients undergoing liver transplantation, the transfusion of plasma to RBC ratio ≥0·85 was associated with decreased need of RBC transfusions. © 2018 International Society of Blood Transfusion.
Comparison of thiazide-like diuretics versus thiazide-type diuretics: a meta-analysis.
Liang, Wenjing; Ma, Hui; Cao, Luxi; Yan, Wenjiang; Yang, Jingjing
2017-11-01
Thiazide diuretics are widely used for the management of hypertension. In recent years, it has been actively debated that there is interchangeability of thiazide-type diuretics hydrochlorothiazide and thiazide-like diuretics including indapamide and chlorthalidone for the treatment of hypertension. With the purpose of seeking out the best thiazide diuretic for clinicians, we summarized the existing evidence on the two types of drugs and conducted a meta-analysis on their efficacy in lowering blood pressure and effects on blood electrolyte, glucose and total cholesterol. Twelve trials were identified: five based on the comparison of indapamide versus hydrochlorothiazide and seven based on the chlorthalidone versus hydrochlorothiazide. In the meta-analysis of blood pressure reduction, thiazide-like diuretics seemed to further reduce systolic BP ([95% CI]; -5.59 [-5.69, -5.49]; P < 0.001) and diastolic BP ([95% CI]; -1.98 [-3.29, -0.66]; P = 0.003). Meanwhile, in the analysis of side effects, the incidence of hypokalemia ([95% CI]; 1.58 [0.80, 3.12]; P = 0.19), hyponatremia ([95% CI]; -0.14 [-0.57, 0.30], P = 0.54), change of blood glucose ([95% CI];0.13 [-0.16, 0.41], P = 0.39) and total cholesterol ([95% CI]; 0.13 [-0.16, 0.41], P = 0.39) showed that there is no statistical significant differences between the two groups of drugs. In conclusion, using thiazide-like diuretics is superior to thiazide-type diuretics in reducing blood pressure without increasing the incidence of hypokalemia, hyponatraemia and any change of blood glucose and serum total cholesterol. © 2017 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.
Bischoff, Karyn; Gaskill, Cynthia; Erb, Hollis N; Ebel, Joseph G; Hillebrandt, Joseph
2010-09-01
The current study compared the LeadCare(R) II test kit system with graphite-furnace atomic absorption spectrometry for blood lead (Pb) analysis in 56 cattle accidentally exposed to Pb in the field. Blood Pb concentrations were determined by LeadCare II within 4 hr of collection and after 72 hr of refrigeration. Blood Pb concentrations were determined by atomic absorption spectrometry, and samples that were coagulated (n = 12) were homogenized before analysis. There was strong rank correlation (R(2) = 0.96) between atomic absorption and LeadCare II (within 4 hr of collection), and a conversion formula was determined for values within the observed range (3-91 mcg/dl, although few had values >40 mcg/dl). Median and mean blood pb concentrations for atomic absorption were 7.7 and 15.9 mcg/dl, respectively; for LeadCare II, medians were 5.2 mcg/dl at 4 hr and 4.9 mcg/dl at 72 hr, and means were 12.4 and 11.7, respectively. LeadCare II results at 4 hr strongly correlated with 72 hr results (R(2) = 0.96), but results at 72 hr were lower (P < 0.01). There was no significant difference between coagulated and uncoagulated samples run by atomic absorption. Although there have been several articles that compared LeadCare with other analytical techniques, all were for the original system, not LeadCare II. The present study indicated that LeadCare II results correlated well with atomic absorption over a wide range of blood Pb concentrations and that refrigerating samples for up to 72 hr before LeadCare II analysis was acceptable for clinical purposes.
Kühlmann, Anne Y R; Etnel, Jonathan R G; Roos-Hesselink, Jolien W; Jeekel, Johannes; Bogers, Ad J J C; Takkenberg, Johanna J M
2016-04-19
Adverse effects, treatment resistance and high costs associated with pharmacological treatment of hypertension have led to growing interest in non-pharmacological complementary therapies such as music interventions. This meta-analysis aims to provide an overview of reported evidence on the efficacy of music interventions in the treatment of hypertension. A systematic literature search was conducted for publications on the effect of music interventions on blood pressure in adult hypertensive subjects published between January 1990-June 2014. Randomized controlled trials with a follow-up duration ≥28 days were included. Blood pressure measures were pooled using inverse variance weighting. Of the 1689 abstracts reviewed, 10 randomized controlled trials were included. Random-effects pooling of the music intervention groups showed a trend toward a decrease in mean systolic blood pressure (SBP) from 144 mmHg(95 % CI:137-152) to 134 mmHg(95 % CI:124-144), and in mean diastolic blood pressure (DBP) from 84 mmHg(95 % CI:78-89) to 78 mmHg(95 % CI:73-84). Fixed-effect analysis of a subgroup of 3 trials with valid control groups showed a significant decrease in pooled mean SBP and DBP in both intervention and control groups. A comparison between music intervention groups and control groups was not possible due to unavailable measures of dispersion. This systematic review and meta-analysis revealed a trend towards a decrease in blood pressure in hypertensive patients who received music interventions, but failed to establish a cause-effect relationship between music interventions and blood pressure reduction. Considering the potential value of this safe, low-cost intervention, well-designed, high quality and sufficiently powered randomized studies assessing the efficacy of music interventions in the treatment of hypertension are warranted.
Clinical, operational and economic outcomes of point-of-care blood gas analysis in COPD patients.
Oliver, Paloma; Buno, Antonio; Alvarez-Sala, Rodolfo; Fernandez-Calle, Pilar; Alcaide, Maria Jose; Casitas, Raquel; Garcia-Quero, Cristina; Madero, Rosario; Gomez-Rioja, Ruben; Iturzaeta, Jose Manuel
2015-04-01
Arterial blood gas analysis is relevant in chronic obstructive pulmonary disease (COPD) management. The aim of this study was to evaluate whether the use of a blood gas analyzer in pulmonology departments improves the clinical, operational and economic outcomes when compared with clinical laboratory measurements. It is an observational prospective study. 112 patients were selected. After specimen collection, the measurement was performed both in pulmonology office as point-of-care and in laboratory. We evaluated clinical outcomes (modification of the indication of long-term oxygen therapy (LTOT) according to results, changes in blood gas analysis results, relationship of the partial pressure of oxygen (PaO2) obtained in the medical visit and velocity of change of the PaO2, influence of total haemoglobin concentration and the change in PaO2), operational outcomes (turnaround time (TAT) from specimen collection to receiving the blood gas analysis report) and economic outcomes (overall cost per process of patient care). There were discrepancies in the indication of LTOT in 13.4% of patients. All parameters showed changes. PaO2 levels showed changes in 2 ways, though they frequently increase over time. The correlation was not good in the other two clinical outcomes. The median TATs in pulmonology office were 1 min versus 79 in laboratory, with 52 min for specimen preparation and transport and 17 min for TAT intralaboratory. The overall cost for the 112 patients in pulmonology office and laboratory was 16,769.89€ and 22,260.97€ respectively. The use of a blood gas analyzer in a pulmonology office improves clinical, operational and economic outcomes when compared with clinical laboratory. Copyright © 2014 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Zhu, Yongjian; Bo, Yacong; Wang, Xi; Lu, Wenjie; Wang, Xule; Han, Zhanying; Qiu, Chunguang
2016-04-01
The findings of clinical studies concerning the association between anthocyanins supplementation and blood pressure (BP) are inconsistent. In order to provide a more precise estimate of the overall effect of anthocyanins on systolic blood pressure (SBP) and diastolic blood pressure (DBP), we conducted a meta-analysis of clinical trials about anthocyanins supplementation and BP. PubMed, Web of Science, Wanfang Database, and China National Knowledge Infrastructure (CNKI) (until October 2015) were searched to identify potential studies with information on anthocyanins extract supplementation and arterial BP. The weighted mean difference (WMD) and 95% confidence interval (CI) were used as a summary statistic. Net changes in SBP and DBP between anthocyanins supplementation and placebo groups were calculated by subtracting the values at end of follow-up from those at baseline. Meta regression was used to explore the potential moderators of effect size. The publication bias was assessed using Begger's Funnel plots and Egger's tests; P < 0.05 was considered to be statistically significant. Finally, 6 clinical studies with 472 participants for the effect of anthocyanins consumption on BP were included in the present meta-analysis. There is no significant effect on either SBP (WMD: 1.15 mm Hg, 95% CI: -3.17 to 5.47, I2 = 56%) or DBP (WMD: 1.06 mm Hg, 95% CI: -0.71 to 2.83, I2 = 0%) following supplementation with anthocyanins. In summary, results from this meta-analysis do not favor any clinical efficacy of supplementation with anthocyanins in improving blood pressure. Further well-designed large randomized controlled trials (RCTs) with long follow-up period are needed to verify the association of anthocyanins supplementation and blood pressure.
Solnica, Bogdan
2009-01-01
In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch® UltraVue™ blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. PMID:20144432
Solnica, Bogdan
2009-09-01
In this issue of Journal of Diabetes Science and Technology, Chang and colleagues present the analytical performance evaluation of the OneTouch UltraVue blood glucose meter. This device is an advanced construction with a color display, used-strip ejector, no-button interface, and short assay time. Accuracy studies were performed using a YSI 2300 analyzer, considered the reference. Altogether, 349 pairs of results covering a wide range of blood glucose concentrations were analyzed. Patients with diabetes performed a significant part of the tests. Obtained results indicate good accuracy of OneTouch UltraVue blood glucose monitoring system, satisfying the International Organization for Standardization recommendations and thereby locating >95% of tests within zone A of the error grid. Results of the precision studies indicate good reproducibility of measurements. In conclusion, the evaluation of the OneTouch UltraVue meter revealed good analytical performance together with convenient handling useful for self-monitoring of blood glucose performed by elderly diabetes patients. 2009 Diabetes Technology Society.
NASA Astrophysics Data System (ADS)
Katura, Takusige; Yagyu, Akihiko; Obata, Akiko; Yamazaki, Kyoko; Maki, Atsushi; Abe, Masanori; Tanaka, Naoki
2007-07-01
Strong spontaneous fluctuations around 0.1 and 0.3 Hz have been observed in blood-related brain-function measurements such as functional magnetic resonance imaging and optical topography (or functional near-infrared spectroscopy). These fluctuations seem to reflect the interaction between the cerebral circulation system and the systemic circulation system. We took an energetic viewpoint in our analysis of the interrelationships between fluctuations in cerebral blood volume (CBV), mean arterial blood pressure (MAP), heart rate (HR), and respiratory rhythm based on multivariate autoregressive modeling. This approach involves evaluating the contribution of each fluctuation or rhythm to specific ones by performing multivariate spectral analysis. The results we obtained show MAP and HR can account slightly for the fluctuation around 0.1 Hz in CBV, while the fluctuation around 0.3 Hz is derived mainly from the respiratory rhythm. During our presentation, we will report on the effects of posture on the interrelationship between the fluctuations and the respiratory rhythm.
Wiergowski, Marek; Reguła, Krystyna; Pieśniak, Dorota; Galer-Tatarowicz, Katarzyna; Szpiech, Beata; Jankowski, Zbigniew
2007-01-01
The present paper emphasizes the most common mistakes committed at the beginning of an analytical procedure. To shorten the time and decrease the cost of determinations of substances with similar to alcohol activity, it is postulated to introduce mass-scale screening analysis of saliva collected from a living subject at the site of the event, with all positive results confirmed in blood or urine samples. If no saliva sample is collected for toxicology, a urine sample, allowing for a stat fast screening analysis, and a blood sample, to confirm the result, should be ensured. Inappropriate storage of a blood sample in the tube without a preservative can cause sample spilling and its irretrievable loss. The authors propose updating the "Blood/urine sampling protocol", with the updated version to be introduced into practice following consultations and revisions.
Modeling intracavitary heating of the uterus by means of a balloon catheter
NASA Astrophysics Data System (ADS)
Olsrud, Johan; Friberg, Britt; Rioseco, Juan; Ahlgren, Mats; Persson, Bertil R. R.
1999-01-01
Balloon thermal endometrial destruction (TED) is a recently developed method to treat heavy menstrual bleeding (menorrhagia). Numerical simulations of this treatment by use of the finite element method were performed. The mechanical deformation and the resulting stress distribution when a balloon catheter is expanded within the uterine cavity was estimated from structural analysis. Thermal analysis was then performed to estimate the depth of tissue coagulation (temperature > 55 degree(s)C) in the uterus during TED. The estimated depth of coagulation, after 30 min heating with an intracavity temperature of 75 degree(s)C, was approximately 9 mm when blood flow was disregarded. With uniform normal blood flow, the depth of coagulation decreased to 3 - 4 mm. Simulations with varying intracavity temperatures and blood flow rates showed that both parameters should be of major importance to the depth of coagulation. The influence of blood flow was less when the pressure due to the balloon was also considered (5 - 6 mm coagulation depth with normal blood flow).
NASA Astrophysics Data System (ADS)
Varghese, Joffin; Jayakumar, J. S.
2017-09-01
Quantifying, forecasting and analysing the displacement rates of suspended particles are essential while discussing about blood flow analysis. Because blood is one of the major organs in the body, which enables transport phenomena, comprising of numerous blood cells. In order to model the blood flow, a flow domain was created and numerically simulated. Flow field velocity in the stream is solved utilizing Finite Volume Method utilizing FVM unstructured solver. In pulsatile flow, the effect of parameters such as average Reynolds number, tube radius, particle size and Womersley number are taken into account. In this study spheroidal particle trajectory in axial direction is simulated at different values of pulsating frequency including 1.2 Hz, 3.33 Hz and 4.00 Hz and various densities including 1005 kg/m3 and 1025 kg/m3 for the flow domain. The analysis accomplishes the interaction study of blood constituents for different flow situations which have applications in diagnosis and treatment of cardio vascular related diseases.
NASA Astrophysics Data System (ADS)
Cheng, Jin-ying; Xu, Liang; Lü, Guo-dong; Tang, Jun; Mo, Jia-qing; Lü, Xiao-yi; Gao, Zhi-xian
2017-01-01
A Raman spectroscopy method combined with neural network is used for the invasive and rapid detection of echinococcosis. The Raman spectroscopy measurements are performed on two groups of blood serum samples, which are from 28 echinococcosis patients and 38 healthy persons, respectively. The normalized Raman reflection spectra show that the reflectivity of the echinococcosis blood serum is higher than that of the normal human blood serum in the wavelength ranges of 101—175 nm and 1 801—2 701 nm. Then the principal component analysis (PCA) and back propagation neural network (BPNN) model are used to obtain the diagnosis results. The diagnosis rates for healthy persons and echinococcosis persons are 93.333 3% and 90.909 1%, respectively, so the average final diagnosis rate is 92.121 2%. The results demonstrate that the Raman spectroscopy analysis of blood serum combined with PCA-BPNN has considerable potential for the non-invasive and rapid detection of echinococcosis.
[Traces of blood. The significance of blood in criminology at the turn of the 19th century].
Bachhiesl, Christian
2010-03-01
In late 19th and early 20th century, criminology became institutionalized as an independent branch of science. Methodologically it focused on the 'exact' methods of the natural sciences, but also it tried to integrate the methods of the humanities. This mix of methods becomes visible in the treatment of blood, which on the one hand was an object of then brand new methods of scientific analysis (identification of human blood by the biological or precipitin method), and on the other hand was analyzed as a product of the magic and superstitious mentalities of criminals. The methodical tension resulting from this epistemological crossbreeding did not disturb the criminologists, for whom the reconciliation of opposite ways of thinking and researching seemed to be possible. In this encyclopaedic analysis of blood early criminology tried to combine the anthropological exploration of vampirism with the chemical and microscopic detection of antibodies and haemoglobin, thus mirroring the positivistic optimism that was then prevalent.
Li, Siyang; Plouffe, Brian D.; Belov, Arseniy M.; Ray, Somak; Wang, Xianzhe; Murthy, Shashi K.; Karger, Barry L.; Ivanov, Alexander R.
2015-01-01
Isolation and molecular characterization of rare cells (e.g. circulating tumor and stem cells) within biological fluids and tissues has significant potential in clinical diagnostics and personalized medicine. The present work describes an integrated platform of sample procurement, preparation, and analysis for deep proteomic profiling of rare cells in blood. Microfluidic magnetophoretic isolation of target cells spiked into 1 ml of blood at the level of 1000–2000 cells/ml, followed by focused acoustics-assisted sample preparation has been coupled with one-dimensional PLOT-LC-MS methodology. The resulting zeptomole detection sensitivity enabled identification of ∼4000 proteins with injection of the equivalent of only 100–200 cells per analysis. The characterization of rare cells in limited volumes of physiological fluids is shown by the isolation and quantitative proteomic profiling of first MCF-7 cells spiked into whole blood as a model system and then two CD133+ endothelial progenitor and hematopoietic cells in whole blood from volunteers. PMID:25755294
NASA Astrophysics Data System (ADS)
Ryu, Jaiyoung; Hu, Xiao; Shadden, Shawn C.
2015-11-01
The brain's CO2 reactivity mechanism is coupled with cerebral autoregulation and other unique features of cerebral hemodynamics. We developed a one-dimensional nonlinear model of blood flow in the cerebral arteries coupled to lumped parameter (LP) networks. The LP networks incorporate cerebral autoregulation, CO2 reactivity, intracranial pressure, cerebrospinal fluid, and cortical collateral blood flow models. The model was used to evaluate hemodynamic variables (arterial deformation, blood velocity and pressure) in the cerebral vasculature during hyperventilation and CO2 inhalation test. Tests were performed for various arterial blood pressure (ABP) representing normal and hypotensive conditions. The increase of the cerebral blood flow rates agreed well with the published measurements for various ABP measurements taken during clinical CO2 reactivity tests. The changes in distal vasculature affected the reflected pulse wave energy, which caused the waveform morphological changes at the middle cerebral, common and internal carotid arteries. The pulse morphological analysis demonstrated agreement with previous clinical measurements for cerebral vasoconstriction and vasodilation.
Decoding the Regulatory Network for Blood Development from Single-Cell Gene Expression Measurements
Haghverdi, Laleh; Lilly, Andrew J.; Tanaka, Yosuke; Wilkinson, Adam C.; Buettner, Florian; Macaulay, Iain C.; Jawaid, Wajid; Diamanti, Evangelia; Nishikawa, Shin-Ichi; Piterman, Nir; Kouskoff, Valerie; Theis, Fabian J.; Fisher, Jasmin; Göttgens, Berthold
2015-01-01
Here we report the use of diffusion maps and network synthesis from state transition graphs to better understand developmental pathways from single cell gene expression profiling. We map the progression of mesoderm towards blood in the mouse by single-cell expression analysis of 3,934 cells, capturing cells with blood-forming potential at four sequential developmental stages. By adapting the diffusion plot methodology for dimensionality reduction to single-cell data, we reconstruct the developmental journey to blood at single-cell resolution. Using transitions between individual cellular states as input, we develop a single-cell network synthesis toolkit to generate a computationally executable transcriptional regulatory network model that recapitulates blood development. Model predictions were validated by showing that Sox7 inhibits primitive erythropoiesis, and that Sox and Hox factors control early expression of Erg. We therefore demonstrate that single-cell analysis of a developing organ coupled with computational approaches can reveal the transcriptional programs that control organogenesis. PMID:25664528
Self-driven filter-based blood plasma separator microfluidic chip for point-of-care testing.
Madadi, Hojjat; Casals-Terré, Jasmina; Mohammadi, Mahdi
2015-05-22
There is currently a growing need for lab-on-a-chip devices for use in clinical analysis and diagnostics, especially in the area of patient care. The first step in most blood assays is plasma extraction from whole blood. This paper presents a novel, self-driven blood plasma separation microfluidic chip, which can extract more than 0.1 μl plasma from a single droplet of undiluted fresh human blood (~5 μl). This volume of blood plasma is extracted from whole blood with high purity (more than 98%) in a reasonable time frame (3 to 5 min), and without the need for any external force. This would be the first step towards the realization of a single-use, self-blood test that does not require any external force or power source to deliver and analyze a fresh whole-blood sample, in contrast to the existing time-consuming conventional blood analysis. The prototypes are manufactured in polydimethylsiloxane that has been modified with a strong nonionic surfactant (Silwet L-77) to achieve hydrophilic behavior. The main advantage of this microfluidic chip design is the clogging delay in the filtration area, which results in an increased amount of extracted plasma (0.1 μl). Moreover, the plasma can be collected in one or more 10 μm-deep channels to facilitate the detection and readout of multiple blood assays. This high volume of extracted plasma is achieved thanks to a novel design that combines maximum pumping efficiency without disturbing the red blood cells' trajectory through the use of different hydrodynamic principles, such as a constriction effect and a symmetrical filtration mode. To demonstrate the microfluidic chip's functionality, we designed and fabricated a novel hybrid microdevice that exhibits the benefits of both microfluidics and lateral flow immunochromatographic tests. The performance of the presented hybrid microdevice is validated using rapid detection of thyroid stimulating hormone within a single droplet of whole blood.
Analysis of artery blood flow before and after angioplasty
NASA Astrophysics Data System (ADS)
Tomaszewski, Michał; Baranowski, Paweł; Małachowski, Jerzy; Damaziak, Krzysztof; Bukała, Jakub
2018-01-01
The study presents a comparison of results obtained from numerical simulations of blood flow in two different arteries. One of them was considered to be narrowed in order to simulate an arteriosclerosis obstructing the blood flow in the vessel, whereas the second simulates the vessel after angioplasty treatment. During the treatment, a biodegradable stent is inserted into the artery, which prevents the vessel walls from collapsing. The treatment was simulated through the use of numerical simulation using the finite element method. The final mesh geometry obtained from the analysis was exported to the dedicated software in order to create geometry in which a flow domain inside the artery with the stent was created. The flow analysis was conducted in ANSYS Fluent software with non-deformable vessel walls.
Histogram analysis for smartphone-based rapid hematocrit determination
Jalal, Uddin M.; Kim, Sang C.; Shim, Joon S.
2017-01-01
A novel and rapid analysis technique using histogram has been proposed for the colorimetric quantification of blood hematocrits. A smartphone-based “Histogram” app for the detection of hematocrits has been developed integrating the smartphone embedded camera with a microfluidic chip via a custom-made optical platform. The developed histogram analysis shows its effectiveness in the automatic detection of sample channel including auto-calibration and can analyze the single-channel as well as multi-channel images. Furthermore, the analyzing method is advantageous to the quantification of blood-hematocrit both in the equal and varying optical conditions. The rapid determination of blood hematocrits carries enormous information regarding physiological disorders, and the use of such reproducible, cost-effective, and standard techniques may effectively help with the diagnosis and prevention of a number of human diseases. PMID:28717569
Zhang, Lu-Kai; Ma, Jian-Xiong; Kuang, Ming-Jie; Zhao, Jie; Wang, Ying; Lu, Bin; Sun, Lei; Ma, Xin-Long
2017-09-01
Tranexamic acid (TXA) is regarded as one of the most important drugs in reducing blood loss and hemoglobin (Hb) drop after total knee arthroplasty (TKA) or total hip arthroplasty (THA). Treatment with tranexamic acid (TXA) by intravenous application has been discussed extensively. Recently, several studies have reported that oral administration has an effect on blood sparing. Therefore, we performed a meta-analysis to investigate the efficacy and safety between oral TXA and intravenous TXA (IV-TXA) for blood sparing in total knee and hip arthroplasty. Randomized controlled trials (RCTs) or retrospective cohort studies (RCSs) about relevant research were searched for by using PubMed (1996-April 2017), Embase (1980-April 2017), and the Cochrane Library (CENTRAL, April 2017). Five studies that compared oral with IV administration of TXA were included in our meta-analysis. Meta-analysis results were collected and analyzed by the software Review Manager 5.3 (Copenhagen: The Nordic Cochrane Center, The Collaboration, 2014). Five studies containing 3474 patients met the inclusion criteria. Our pooled data analysis indicated that oral TXA was as effective as the IV-TXA in terms of the average Hb drop (P = 0.88), total Hb loss (P = 0.57), total blood loss (P = 0.42), transfusion rate (P = 0.16), complications (P = 0.61), and length of hospital stay (P = 1.00). Compared with the IV-TXA method, oral TXA shows similar blood-sparing efficacy for preventing hemoglobin drop, total hemoglobin loss, and total blood loss following TKA or THA. In addition, no significant differences of transfusion rate, complications, or length of hospital stay were found between the 2 groups. However, because of the limited number of included studies, more studies of high quality are needed to further identify the optimal administration time for oral TXA. Copyright © 2017 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Dostálová, Anna; Votýpka, Jan; Favreau, Amanda J; Barbian, Kent D; Volf, Petr; Valenzuela, Jesus G; Jochim, Ryan C
2011-05-10
Parasite-vector interactions are fundamental in the transmission of vector-borne diseases such as leishmaniasis. Leishmania development in the vector sand fly is confined to the digestive tract, where sand fly midgut molecules interact with the parasites. In this work we sequenced and analyzed two midgut-specific cDNA libraries from sugar fed and blood fed female Phlebotomus perniciosus and compared the transcript expression profiles. A total of 4111 high quality sequences were obtained from the two libraries and assembled into 370 contigs and 1085 singletons. Molecules with putative roles in blood meal digestion, peritrophic matrix formation, immunity and response to oxidative stress were identified, including proteins that were not previously reported in sand flies. These molecules were evaluated relative to other published sand fly transcripts. Comparative analysis of the two libraries revealed transcripts differentially expressed in response to blood feeding. Molecules up regulated by blood feeding include a putative peritrophin (PperPer1), two chymotrypsin-like proteins (PperChym1 and PperChym2), a putative trypsin (PperTryp3) and four putative microvillar proteins (PperMVP1, 2, 4 and 5). Additionally, several transcripts were more abundant in the sugar fed midgut, such as two putative trypsins (PperTryp1 and PperTryp2), a chymotrypsin (PperChym3) and a microvillar protein (PperMVP3). We performed a detailed temporal expression profile analysis of the putative trypsin transcripts using qPCR and confirmed the expression of blood-induced and blood-repressed trypsins. Trypsin expression was measured in Leishmania infantum-infected and uninfected sand flies, which identified the L. infantum-induced down regulation of PperTryp3 at 24 hours post-blood meal. This midgut tissue-specific transcriptome provides insight into the molecules expressed in the midgut of P. perniciosus, an important vector of visceral leishmaniasis in the Old World. Through the comparative analysis of the libraries we identified molecules differentially expressed during blood meal digestion. Additionally, this study provides a detailed comparison to transcripts of other sand flies. Moreover, our analysis of putative trypsins demonstrated that L. infantum infection can reduce the transcript abundance of trypsin PperTryp3 in the midgut of P. perniciosus.
NASA Astrophysics Data System (ADS)
Zhang, Linna; Li, Gang; Sun, Meixiu; Li, Hongxiao; Wang, Zhennan; Li, Yingxin; Lin, Ling
2017-11-01
Identifying whole bloods to be either human or nonhuman is an important responsibility for import-export ports and inspection and quarantine departments. Analytical methods and DNA testing methods are usually destructive. Previous studies demonstrated that visible diffuse reflectance spectroscopy method can realize noncontact human and nonhuman blood discrimination. An appropriate method for calibration set selection was very important for a robust quantitative model. In this paper, Random Selection (RS) method and Kennard-Stone (KS) method was applied in selecting samples for calibration set. Moreover, proper stoichiometry method can be greatly beneficial for improving the performance of classification model or quantification model. Partial Least Square Discrimination Analysis (PLSDA) method was commonly used in identification of blood species with spectroscopy methods. Least Square Support Vector Machine (LSSVM) was proved to be perfect for discrimination analysis. In this research, PLSDA method and LSSVM method was used for human blood discrimination. Compared with the results of PLSDA method, this method could enhance the performance of identified models. The overall results convinced that LSSVM method was more feasible for identifying human and animal blood species, and sufficiently demonstrated LSSVM method was a reliable and robust method for human blood identification, and can be more effective and accurate.
High Maternal Blood Mercury Level Is Associated with Low Verbal IQ in Children.
Jeong, Kyoung Sook; Park, Hyewon; Ha, Eunhee; Shin, Jiyoung; Hong, Yun Chul; Ha, Mina; Park, Hyesook; Kim, Bung Nyun; Lee, Boeun; Lee, Soo Jeong; Lee, Kyung Yeon; Kim, Ja Hyeong; Kim, Yangho
2017-07-01
The objective of the present study was to investigate the relationship of IQ in children with maternal blood mercury concentration during late pregnancy. The present study is a component of the Mothers and Children's Environmental Health (MOCEH) study, a multi-center birth cohort project in Korea that began in 2006. The study cohort consisted of 553 children whose mothers underwent testing for blood mercury during late pregnancy. The children were given the Korean language version of the Wechsler Preschool and Primary Scale of Intelligence, revised edition (WPPSI-R) at 60 months of age. Multivariate linear regression analysis, with adjustment for covariates, was used to assess the relationship between verbal, performance, and total IQ in children and blood mercury concentration of mothers during late pregnancy. The results of multivariate linear regression analysis indicated that a doubling of blood mercury was associated with the decrease in verbal and total IQ by 2.482 (95% confidence interval [CI], 0.749-4.214) and 2.402 (95% CI, 0.526-4.279), respectively, after adjustment. This inverse association remained after further adjustment for blood lead concentration. Fish intake is an effect modifier of child IQ. In conclusion, high maternal blood mercury level is associated with low verbal IQ in children. © 2017 The Korean Academy of Medical Sciences.
Potential Biomarker Peptides Associated with Acute Alcohol-Induced Reduction of Blood Pressure
Wakabayashi, Ichiro; Marumo, Mikio; Nonaka, Daisuke; Shimomura, Tomoko; Eguchi, Ryoji; Lee, Lyang-Ja; Tanaka, Kenji; Hatake, Katsuhiko
2016-01-01
The purpose of this study was to explore the peptides that are related to acute reduction of blood pressure after alcohol drinking. Venous blood was collected from male healthy volunteers before and after drinking white wine (3 ml/kg weight) containing 13% of ethanol. Peptidome analysis for serum samples was performed using a new target plate, BLOTCHIP®. Alcohol caused significant decreases in systolic and diastolic blood pressure levels at 45 min. The peptidome analysis showed that the levels of three peptides of m/z 1467, 2380 and 2662 changed significantly after drinking. The m/z 1467 and 2662 peptides were identified to be fragments of fibrinogen alpha chain, and the m/z 2380 peptide was identified to be a fragment of complement C4. The intensities of the m/z 2380 and m/z 1467 peptides before drinking were associated with % decreases in systolic and diastolic blood pressure levels at 45 min after drinking compared with the levels before drinking, while there were no significant correlations between the intensity of the m/z 2662 peptide and % decreases in systolic and diastolic blood pressure levels after drinking. The m/z 1467 and 2380 peptides are suggested to be markers for acute reduction of blood pressure after drinking alcohol. PMID:26815288
Blood Pump Development Using Rocket Engine Flow Simulation Technology
NASA Technical Reports Server (NTRS)
Kwak, Dochan; Kiris, Cetin
2001-01-01
This paper reports the progress made towards developing complete blood flow simulation capability in humans, especially in the presence of artificial devices such as valves and ventricular assist devices. Devices modeling poses unique challenges different from computing the blood flow in natural hearts and arteries. There are many elements needed to quantify the flow in these devices such as flow solvers, geometry modeling including flexible walls, moving boundary procedures and physiological characterization of blood. As a first step, computational technology developed for aerospace applications was extended to the analysis and development of a ventricular assist device (VAD), i.e., a blood pump. The blood flow in a VAD is practically incompressible and Newtonian, and thus an incompressible Navier-Stokes solution procedure can be applied. A primitive variable formulation is used in conjunction with the overset grid approach to handle complex moving geometry. The primary purpose of developing the incompressible flow analysis capability was to quantify the flow in advanced turbopump for space propulsion system. The same procedure has been extended to the development of NASA-DeBakey VAD that is based on an axial blood pump. Due to massive computing requirements, high-end computing is necessary for simulating three-dimensional flow in these pumps. Computational, experimental, and clinical results are presented.
Pos Pok, P-Rop; Haddouche, Djamel; Mauras, Michel; Kuhlmann, Erika; Burle, Joëlle; Salmon, Thierry; Berland, Emilie; Coiffait, P-Emmanuel; Viala, Alain
2008-01-01
Concomitant heart and peripheral blood determinations were performed on 40 fatal cases involving nordiazepam (20 cases) and bromazepam (20 cases). The heart blood concentration for the two drugs (588 ng/mL for nordiazepam and 802 ng/mL for bromazepam) does not differ from the corresponding peripheral blood concentration (587 ng/mL for nordiazepam and 883 ng/mL for bromazepam). The mean ratios for the heart and peripheral blood concentrations were 0.95 for nordiazepam and 0.86 for bromazepam. No postmortem redistribution was observed for these two benzodiazepines. The authors thus suggest that corresponding heart blood can be proposed in the quantitative analysis of these drugs when peripheral blood is unavailable. The present study also shows the stability of the two drugs after a year of storage.
Blood oxygenation and flow measurements using a single 720-nm tunable V-cavity laser.
Feng, Yafei; Deng, Haoyu; Chen, Xin; He, Jian-Jun
2017-08-01
We propose and demonstrate a single-laser-based sensing method for measuring both blood oxygenation and microvascular blood flow. Based on the optimal wavelength range found from theoretical analysis on differential absorption based blood oxygenation measurement, we designed and fabricated a 720-nm-band wavelength tunable V-cavity laser. Without any grating or bandgap engineering, the laser has a wavelength tuning range of 14.1 nm. By using the laser emitting at 710.3 nm and 724.4 nm to measure the oxygenation and blood flow, we experimentally demonstrate the proposed method.
Strandenes, Geir; Austlid, Ivar; Apelseth, Torunn O; Hervig, Tor A; Sommerfelt-Pettersen, Jan; Herzig, Maryanne C; Cap, Andrew P; Pidcoke, Heather F; Kristoffersen, Einar K
2015-06-01
Formulation of a medical preparedness plan for treating severely bleeding casualties during naval deployment is a significant challenge because of territory covered during most missions. The aim of this study was to evaluate the concept of "walking blood bank" as a supportable plan for supplying safe blood and blood products. In 2013, the Royal Norwegian Navy conducted antipiracy operations from a frigate, beginning in the Gulf of Aden and ending in the Indian Ocean. Crews were on 24-hour emergency alert in preparation for an enemy assault on the frigate. Under an approved command protocol, a "walking blood bank," using crew blood donations, was established for use on board and on missions conducted in rigid-hulled inflatable boats, during which freeze-dried plasma and leukoreduced, group O low anti-A/anti-B titer, cold-stored whole blood were stored in Golden Hour Boxes. Data demonstrating the ability to collect, store, and provide whole blood were collected to establish feasibility of implementing a whole blood-focused remote damage-control resuscitation program aboard a naval vessel. In addition, ROTEM data were collected to demonstrate feasibility of performing this analysis on a large naval vessel and to also measure hemostatic efficacy of cold-stored leukoreduced whole blood (CWB) stored during a period of 14 days. ROTEM data on CWB was compared with reconstituted whole blood. Drills simulating massive transfusion activation were conducted, in which 2 U of warm fresh whole blood with platelet sparing leukoreduction were produced in 40 minutes, followed by collection of two additional units at 15-minute increments. The ROTEM machine performed well during ship-rolling, as shown by the overlapping calculated and measured mechanical piston movements measured by the ROTEM device. Error messages were recorded in 4 (1.5%) of 267 tests. CWB yielded reproducible ROTEM results demonstrating preserved fibrinogen function and platelet function for at least 3.5 weeks and 2 weeks, respectively. The frequency of ROTEM tests were as follows: EXTEM (n = 88), INTEM (n = 85), FIBTEM (n = 82), and APTEM (n = 12). CWB results were grouped. Compared with Days 0 to 2, EXTEM maximum clot firmness was significantly reduced, beginning on Days 10 to 14; however, results through that date remained within reference ranges and were comparable with the EXTEM maximum clot firmness for the reconstituted whole blood samples containing Day 5 room temperature-stored platelets. A "walking blood bank" can provide a balanced transfusion product to support damage-control resuscitation/remote damage-control resuscitation aboard a frigate in the absence of conventional blood bank products. ROTEM analysis is feasible to monitor damage-control resuscitation and blood product quality. ROTEM analysis was possible in challenging operational conditions. Therapeutic study, level V.
Emerging microengineering tools for functional analysis and phenotyping of blood cells
Li, Xiang; Chen, Weiqiang; Li, Zida; Li, Ling; Gu, Hongchen; Fu, Jianping
2014-01-01
The available techniques for assessing blood cell functions are limited considering the various types of blood cells and their diverse functions. In the past decade, rapid advancement in microengineering has enabled an array of blood cell functional measurements that are difficult or impossible to achieve using conventional bulk platforms. Such miniaturized blood cell assay platforms also provide attractive capabilities of reducing chemical consumption, cost, assay time, as well as exciting opportunities of device integration, automation, and assay standardization. This review summarizes these contemporary microengineering tools and discusses their promising potential for constructing accurate in vitro models and rapid clinical diagnosis using minimal amount of whole blood samples. PMID:25283971
Liu, Hongyun; Li, Kaiyuan; Zhang, Zhengbo; Guo, Junyan; Wang, Weidong
2012-11-01
The correlation coefficients between arterial occlusion pressure and systolic blood pressure, diastolic blood pressure, limb circumference, body mass etc were obtained through healthy volunteer experiments, in which tourniquet were applied on upper/lower extremities. The prediction equations were derived from the data of experiments by multiple regression analysis. Based on the microprocessor C8051F340, a new pneumatic tourniquet system that can determine tourniquet pressure in synchrony with systolic blood pressure was developed and verified the function and stability of designed system. Results showed that the pneumatic tourniquet which automatically adjusts occlusion pressure in accordance with systolic blood pressure could stop the flow of blood to get a bloodless field.
Weymann, Alexander; Ali-Hasan-Al-Saegh, Sadeq; Sabashnikov, Anton; Popov, Aron-Frederik; Mirhosseini, Seyed Jalil; Liu, Tong; Lotfaliani, Mohammadreza; de Oliveira Sá, Michel Pompeu Barros; Baker, William L.; Yavuz, Senol; Zeriouh, Mohamed; Jang, Jae-Sik; Dehghan, Hamidreza; Meng, Lei; Testa, Luca; D’Ascenzo, Fabrizio; Benedetto, Umberto; Tse, Gary; Nombela-Franco, Luis; Dohmen, Pascal M.; Deshmukh, Abhishek J.; Linde, Cecilia; Biondi-Zoccai, Giuseppe; Stone, Gregg W.; Calkins, Hugh
2017-01-01
Background Atrial fibrillation (AF) is one of the most critical and frequent arrhythmias precipitating morbidities and mortalities. The complete blood count (CBC) test is an important blood test in clinical practice and is routinely used in the workup of cardiovascular diseases. This systematic review with meta-analysis aimed to determine the strength of evidence for evaluating the association of hematological parameters in the CBC test with new-onset and recurrent AF. Material/Methods We conducted a meta-analysis of observational studies evaluating hematologic parameters in patients with new-onset AF and recurrent AF. A comprehensive subgroup analysis was performed to explore potential sources of heterogeneity. Results The literature search of all major databases retrieved 2150 studies. After screening, 70 studies were analyzed in the meta-analysis on new-onset AF and 23 studies on recurrent AF. Pooled analysis on new-onset AF showed platelet count (PC) (weighted mean difference (WMD)=WMD of −26.39×109/L and p<0.001), mean platelet volume (MPV) (WMD=0.42 FL and p<0.001), white blood cell (WBC) (WMD=−0.005×109/L and p=0.83), neutrophil to lymphocyte ratio (NLR) (WMD=0.89 and p<0.001), and red blood cell distribution width (RDW) (WMD=0.61% and p<0.001) as associated factors. Pooled analysis on recurrent AF revealed PC (WMD=−2.71×109/L and p=0.59), WBC (WMD=0.20×109/L (95% CI: 0.08 to 0.32; p=0.002), NLR (WMD=0.37 and p<0.001), and RDW (WMD=0.28% and p<0.001). Conclusions Hematological parameters have significant ability to predict occurrence and recurrence of AF. Therefore, emphasizing the potential predictive role of hematological parameters for new-onset and recurrent AF, we recommend adding the CBC test to the diagnostic modalities of AF in clinical practice. PMID:28496093
Weymann, Alexander; Ali-Hasan-Al-Saegh, Sadeq; Sabashnikov, Anton; Popov, Aron-Frederik; Mirhosseini, Seyed Jalil; Liu, Tong; Lotfaliani, Mohammadreza; Sá, Michel Pompeu Barros de Oliveira; Baker, William L L; Yavuz, Senol; Zeriouh, Mohamed; Jang, Jae-Sik; Dehghan, Hamidreza; Meng, Lei; Testa, Luca; D'Ascenzo, Fabrizio; Benedetto, Umberto; Tse, Gary; Nombela-Franco, Luis; Dohmen, Pascal M; Deshmukh, Abhishek J; Linde, Cecilia; Biondi-Zoccai, Giuseppe; Stone, Gregg W; Calkins, Hugh; Surgery And Cardiology-Group Imcsc-Group, Integrated Meta-Analysis Of Cardiac
2017-05-12
BACKGROUND Atrial fibrillation (AF) is one of the most critical and frequent arrhythmias precipitating morbidities and mortalities. The complete blood count (CBC) test is an important blood test in clinical practice and is routinely used in the workup of cardiovascular diseases. This systematic review with meta-analysis aimed to determine the strength of evidence for evaluating the association of hematological parameters in the CBC test with new-onset and recurrent AF. MATERIAL AND METHODS We conducted a meta-analysis of observational studies evaluating hematologic parameters in patients with new-onset AF and recurrent AF. A comprehensive subgroup analysis was performed to explore potential sources of heterogeneity. RESULTS The literature search of all major databases retrieved 2150 studies. After screening, 70 studies were analyzed in the meta-analysis on new-onset AF and 23 studies on recurrent AF. Pooled analysis on new-onset AF showed platelet count (PC) (weighted mean difference (WMD)=WMD of -26.39×10^9/L and p<0.001), mean platelet volume (MPV) (WMD=0.42 FL and p<0.001), white blood cell (WBC) (WMD=-0.005×10^9/L and p=0.83), neutrophil to lymphocyte ratio (NLR) (WMD=0.89 and p<0.001), and red blood cell distribution width (RDW) (WMD=0.61% and p<0.001) as associated factors. Pooled analysis on recurrent AF revealed PC (WMD=-2.71×109/L and p=0.59), WBC (WMD=0.20×10^9/L (95% CI: 0.08 to 0.32; p=0.002), NLR (WMD=0.37 and p<0.001), and RDW (WMD=0.28% and p<0.001). CONCLUSIONS Hematological parameters have significant ability to predict occurrence and recurrence of AF. Therefore, emphasizing the potential predictive role of hematological parameters for new-onset and recurrent AF, we recommend adding the CBC test to the diagnostic modalities of AF in clinical practice.
Minamimoto, Ryogo; Hamabe, Yoshimi; Miyaoka, Teiji; Hara, Takamitsu; Yoshida, Keisuke; Oka, Takashi; Inoue, Tomio
2008-12-01
Phase 0 clinical studies, which are known as microdose trials, are expected to promote drug development and reduce development costs. The accelerator mass spectrometry (AMS) system is expected to play an important role in the microdosing tests, as it is a highly sensitive measurement system that can be used to determine the drug concentrations in these tests. Using the AMS system, we measured the background (14)C-concentration in human blood and evaluated the data for use as a reference in microdose studies that administer (14)C-labeled compounds in humans. Blood samples of five healthy Japanese volunteers (three men, two women, median age 40.4 +/- 9.8 years) were collected around the same time and just prior to when the subjects ate a meal (between 12:00 noon and 2:00 pm). Centrifugal separations of blood that was allowed to clot and the plasma were performed at 503 g for 2 min at 4 degrees C. Background (14)C-concentration for each of the samples was measured using the AMS system. The Institute of Accelerator Analysis, which is the first contract research organization in Japan that is capable of providing AMS analysis services for carbon dating and bioanalysis work, performed the AMS analysis. The mean (14)C-concentration in blood was 1.613 +/- 0.125 dpm/ml (men 1.668 +/- 0.114 dpm/ml, women 1.514 +/- 0.076 dpm/ml), in clots 2.373 +/- 0.087 dpm/ml (men 2.381 +/- 0.101 dpm/ml, women 2.357 +/- 0.060 dpm/ ml), and in plasma 0.648 +/- 0.049 dpm/ml (men 0.647 +/- 0.059 dpm/ml, women 0.649 +/- 0.032 dpm/ml). The coefficient variation (CV) for blood was 7.8% (men 6.9%, women 5.0%), for clots 3.7% (men 4.3%, women 2.5%), and for plasma 7.6% (men 9.1%, women 4.9%). The (14)C-concentrations of the clot and blood were higher than those of plasma. The (14)C-concentrations in the blood and plasma were slightly different between individuals when compared with the values for the clot, although the differences were quite small, with a CV value less than 7.8%. Even though the (14)C-concentration differed only slightly between individuals, (14)C-concentrations of the clot and blood were higher than those of the plasma. Therefore, the variation and difference of the background data for blood and plasma might be of use as a reference for microdosing test evaluations.
Radiation biodosimetry: Applications for spaceflight
NASA Astrophysics Data System (ADS)
Blakely, W. F.; Miller, A. C.; Grace, M. B.; McLeland, C. B.; Luo, L.; Muderhwa, J. M.; Miner, V. L.; Prasanna, P. G. S.
The multiparametric dosimetry system that we are developing for medical radiological defense applications could be adapted for spaceflight environments. The system complements the internationally accepted personnel dosimeters and cytogenetic analysis of chromosome aberrations, considered the best means of documenting radiation doses for health records. Our system consists of a portable hematology analyzer, molecular biodosimetry using nucleic acid and antigen-based diagnostic equipment, and a dose assessment management software application. A dry-capillary tube reagent-based centrifuge blood cell counter (QBC Autoread Plus, Beckon Dickinson Bioscience) measures peripheral blood lymphocytes and monocytes, which could determine radiation dose based on the kinetics of blood cell depletion. Molecular biomarkers for ionizing radiation exposure (gene expression changes, blood proteins) can be measured in real time using such diagnostic detection technologies as miniaturized nucleic acid sequences and antigen-based biosensors, but they require validation of dose-dependent targets and development of optimized protocols and analysis systems. The Biodosimetry Assessment Tool, a software application, calculates radiation dose based on a patient's physical signs and symptoms and blood cell count analysis. It also annotates location of personnel dosimeters, displays a summary of a patient's dosimetric information to healthcare professionals, and archives the data for further use. These radiation assessment diagnostic technologies can have dual-use applications supporting general medical-related care.
On-chip wavelength multiplexed detection of cancer DNA biomarkers in blood
Cai, H.; Stott, M. A.; Ozcelik, D.; Parks, J. W.; Hawkins, A. R.; Schmidt, H.
2016-01-01
We have developed an optofluidic analysis system that processes biomolecular samples starting from whole blood and then analyzes and identifies multiple targets on a silicon-based molecular detection platform. We demonstrate blood filtration, sample extraction, target enrichment, and fluorescent labeling using programmable microfluidic circuits. We detect and identify multiple targets using a spectral multiplexing technique based on wavelength-dependent multi-spot excitation on an antiresonant reflecting optical waveguide chip. Specifically, we extract two types of melanoma biomarkers, mutated cell-free nucleic acids —BRAFV600E and NRAS, from whole blood. We detect and identify these two targets simultaneously using the spectral multiplexing approach with up to a 96% success rate. These results point the way toward a full front-to-back chip-based optofluidic compact system for high-performance analysis of complex biological samples. PMID:28058082
NASA Technical Reports Server (NTRS)
1999-01-01
The method that is used for the collection, storage and real-time analysis of blood and other bodily fluids has been licensed to DBCD, Inc. by NASA. The result of this patent licensing agreement has been the development of a commercial product that can provide serum or plasma from whole blood volumes of 20 microliters to 4 milliliters. The device has a fibrous filter with a pore size of less than about 3 microns, and is coated with a mixture of mannitol and plasma fraction protein. The coating causes the cellular fraction to be trapped by the small pores, leaving the cellular fraction intact on the fibrous filter while the acellular fraction passes through the filter for collection in unaltered form from the serum sample collection chamber. The method used by this product is useful to NASA for blood analysis on manned space missions.
Direct analysis of [6,6-(2)H2]glucose and [U-(13)C6]glucose dry blood spot enrichments by LC-MS/MS.
Coelho, Margarida; Mendes, Vera M; Lima, Inês S; Martins, Fátima O; Fernandes, Ana B; Macedo, M Paula; Jones, John G; Manadas, Bruno
2016-06-01
A liquid chromatography tandem mass spectrometry (LC-MS/MS) using multiple reaction monitoring (MRM) in a triple-quadrupole scan mode was developed and comprehensively validated for the determination of [6,6-(2)H2]glucose and [U-(13)C6]glucose enrichments from dried blood spots (DBS) without prior derivatization. The method is demonstrated with dried blood spots obtained from rats administered with a primed-constant infusion of [U-(13)C6]glucose and an oral glucose load enriched with [6,6-(2)H2]glucose. The sensitivity is sufficient for analysis of the equivalent to <5μL of blood and the overall method was accurate and precise for the determination of DBS isotopic enrichments. Copyright © 2016 Elsevier B.V. All rights reserved.
Ayres, N.; Holt, D. J.; Jones, C.F.; Corum, L. E.; Grainger, D. W.
2009-01-01
A new polymer brush chemistry containing sulfonated carbohydrate repeat units has been synthesized from silicon substrates using ATRP methods and characterized both in bulk and using surface analysis. The polymer brush was designed to act as a mimic for the naturally occurring sulfonated glycosaminoglycan, heparin, commonly used for modifying blood-contacting surfaces both in vitro and in vivo. Surface analysis showed conversion of brush saccharide precursor chemistry to the desired sulfonated polymer product. The sulfonated polymer brush surface was further analyzed using three conventional in vitro tests for blood compatibility -- plasma recalcification times, complement activation, and thrombin generation. The sulfonated polymer brush films on silicon oxide wafers exhibited better assay performance in these blood component assays than the unsulfonated sugar functionalized polymer brush in all tests performed. PMID:19859552
Singla, Lachhman Das; Sumbria, Deepak; Mandhotra, Ajay; Bal, M S; Kaur, Paramjit
2016-12-01
There are few published studies on various vector borne diseases of dogs in India and most depict clinical infection in dogs, diagnosed by observation of the haemopathogens in stained blood smears. This study provides the first report regarding molecular confirmation and ancestral relationship analysis of blood smears positive cases of assorted haemopathogens in Punjab province of India. On blood smear examination, haemopathogens were observed in 124 out of 778 (15.95%, 95% CI: 13.53- 18.68) blood smears. Further polymerase chain reactions (PCR) was used on bloods smear positive cases to validate the results. Out of 778 blood samples, Babesia gibsoni was most common parasite infecting dogs (15.04%, 95% CI: 12.7-17.72), followed by Ehrlichia canis (0.39%, 95% CI: 0.0-1.13), infection of Babesia vogeli and Hepatozoon canis was same (0.26%, 95% CI: 0.0-0.9). Among various risk factors studied (age, sex, season), prevalence of infection was non-significantly higher in 1-2 year of age group (19.88%, 95% CI: 14.45-26.71), regarding sex same prevalence was recorded (15.94%), and chances of infection was highest in pre-monsoon i.e. summer (18.26%, 95% CI: 14.49-22.76). Phylogenetic analysis revealed ancestral background of Ludhiana isolates of B. vogeli, B. gibsoni, H. canis, and E. canis with the isolates of Philippines, Mongolia and Tunisia.
Basu, Sanjay; Hong, Anthony; Siddiqi, Arjumand
2015-08-15
To lower the prevalence of hypertension and racial disparities in hypertension, public health agencies have attempted to reduce modifiable risk factors for high blood pressure, such as excess sodium intake or high body mass index. In the present study, we used decomposition methods to identify how population-level reductions in key risk factors for hypertension could reshape entire population distributions of blood pressure and associated disparities among racial/ethnic groups. We compared blood pressure distributions among non-Hispanic white, non-Hispanic black, and Mexican-American persons using data from the US National Health and Nutrition Examination Survey (2003-2010). When using standard adjusted logistic regression analysis, we found that differences in body mass index were the only significant explanatory correlate to racial disparities in blood pressure. By contrast, our decomposition approach provided more nuanced revelations; we found that disparities in hypertension related to tobacco use might be masked by differences in body mass index that significantly increase the disparities between black and white participants. Analysis of disparities between white and Mexican-American participants also reveal hidden relationships between tobacco use, body mass index, and blood pressure. Decomposition offers an approach to understand how modifying risk factors might alter population-level health disparities in overall outcome distributions that can be obscured by standard regression analyses. © The Author 2015. Published by Oxford University Press on behalf of the Johns Hopkins Bloomberg School of Public Health.
Petit, Morgane; Mine, Louis; Pascreau, Tiffany; Brouzes, Chantal; Majoux, Sandrine; Borgel, Delphine; Beaudeux, Jean-Louis; Lasne, Dominique; Hennequin, Carole
2017-12-01
Pneumatic tube delivery system (PTS) enables to reduce considerably turnaround times. The aim of the study was to assess the influence of the PTS on the quality of routine biochemical and hematological tests in our laboratory. Blood samples from 6 hospitalized patients and 8 healthy volunteers were analyzed. Blood samples were delivered to the laboratory by a PTS and by a human courier. We performed the following analysis: ionized calcium, sodium, potassium, lactate deshydrogenase (LDH), aspartate aminotransferase (ASAT), arterial blood gas, complete blood count and coagulation test as prothrombin time, activated partial thromboplastin time, factors V and VIII. Results were compared between the both method of transport according to the recommendation of the Société française de biologie clinique and the French committee for accreditation (SH-GTA01, norme NF ISO 5275-6). The hemolysis index of plasma was similar between the groups and no morphological differences were found on blood cells. For three samples, when delivered by PTS, LDH levels (two samples) and neutrophil polynuclear count (one sample) were above the recommended guidelines compared to those delivered by courier. Conversely, LDH levels and FVIII were below in two samples delivered by PTS. LDH levels, PNN count or factor VIII can be affected by PTS without the clinical interpretation being modified. We concluded that the PTS can be used to transport blood samples for routine biochemical and hematological analysis in our hospital.
Utility of blood pressure genetic risk score in admixed Hispanic samples.
Beecham, A H; Wang, L; Vasudeva, N; Liu, Z; Dong, C; Goldschmidt-Clermont, P J; Pericak-Vance, M A; Rundek, T; Seo, D; Blanton, S H; Sacco, R L; Beecham, G W
2016-12-01
Hypertension is strongly influenced by genetic factors. Although hypertension prevalence in some Hispanic sub-populations is greater than in non-Hispanic whites, genetic studies on hypertension have focused primarily on samples of European descent. A recent meta-analysis of 200 000 individuals of European descent identified 29 common genetic variants that influence blood pressure, and a genetic risk score derived from the 29 variants has been proposed. We sought to evaluate the utility of this genetic risk score in Hispanics. The sample set consists of 1994 Hispanics from 2 cohorts: the Northern Manhattan Study (primarily Dominican/Puerto Rican) and the Miami Cardiovascular Registry (primarily Cuban/South American). Risk scores for systolic and diastolic blood pressure were computed as a weighted sum of the risk alleles, with the regression coefficients reported in the European meta-analysis used as weights. Association of risk score with blood pressure was tested within each cohort, adjusting for age, age 2 , sex and body mass index. Results were combined using an inverse-variance meta-analysis. The risk score was significantly associated with blood pressure in our combined sample (P=5.65 × 10 -4 for systolic and P=1.65 × 10 -3 for diastolic) but the magnitude of the effect sizes varied by degree of European, African and Native American admixture. Further studies among other Hispanic sub-populations are needed to elucidate the role of these 29 variants and identify additional genetic and environmental factors contributing to blood pressure variability in Hispanics.
Zhu, Y Q; Long, Q; Xiao, Q F; Zhang, M; Wei, Y L; Jiang, H; Tang, B
2018-03-13
Objective: To investigate the association of blood pressure variability and sleep stability in essential hypertensive patients with sleep disorder by cardiopulmonary coupling. Methods: Performed according to strict inclusion and exclusion criteria, 88 new cases of essential hypertension who came from the international department and the cardiology department of china-japan friendship hospital were enrolled. Sleep stability and 24 h ambulatory blood pressure data were collected by the portable sleep monitor based on cardiopulmonary coupling technique and 24 h ambulatory blood pressure monitor. Analysis the correlation of blood pressure variability and sleep stability. Results: In the nighttime, systolic blood pressure standard deviation, systolic blood pressure variation coefficient, the ratio of the systolic blood pressure minimum to the maximum, diastolic blood pressure standard deviation, diastolic blood pressure variation coefficient were positively correlated with unstable sleep duration ( r =0.185, 0.24, 0.237, 0.43, 0.276, P <0.05). Conclusions: Blood pressure variability is associated with sleep stability, especially at night, the longer the unstable sleep duration, the greater the variability in night blood pressure.
Diagnostics of jaundice from the change of the transmission coefficient of the human body
NASA Astrophysics Data System (ADS)
Guminetskiy, S. G.; Kirsh, N. L.; Lomanets, V. S.; Lazurka, I. I.; Yakobets, I. I.
2004-06-01
The paper deals with the absorption spectra of bilirubin solutions, patient blood plasma with jaundice manifestations with a different degree of disease and whole blood. Using as an analysis base the dependencies of blood plasma absorption spectra on bilirubin concentration in this blood there has been proposed the method of disease diagnostics with jaundice manifestations, and there has been realized the corresponding portable laboratory device, the functioning of which is based on registering the radiation propagated through the ear lobule.
1990-12-01
ears ( tinnitus ) and/or a reduced auditory acuity resulted from the dosing. These side effects have been shown to 29 occur in some subjects as a result of...examinations. 5. Complete blood count (CBC). 6. Blood biochemistry screen (Chem 18 including liver function tests). 7. Blood cholesterol and lipids . 8. Chest X...blood lipids and cholesterol, chest X-ray, urinalysis, visual acuity test, vestibular evaluation and liver function studies. Subjects will then take
Sass, Reuben G
2013-01-01
Although excess blood collection has characterized U.S. national disasters, most dramatically in the case of September 11, periodic shortages of blood have recurred for decades. In response, I propose a new model of medical philanthropy, one that specifically uses charitable contributions to health care as blood donation incentives. I explain how the surge in blood donations following 9/11 was both transient and disaster-specific, failing to foster a greater continuing commitment to donate blood. This underscores the importance of considering blood donation incentives. I defend charitable incentives as an alternative to financial incentives, which I contend would further extend neoliberal market values into health care. I explain my model's potential appeal to private foundations or public-private partnerships as a means for expanding both the pool of blood donors and the prosocial benefit of each act of blood donation. Finally I link my analysis to the empirical literature on blood donation incentives.
Is There an Association between Keloids and Blood Groups?
Mouhari-Toure, Abas; Saka, Bayaki; Kombaté, Koussaké; Akakpo, Sefako; Egbohou, Palakiyem; Tchangaï-Walla, Kissem; Pitche, Palokinam
2012-01-01
Objective. The aim of the study is to investigate the possible associations between the blood groups ABO and Rhesus systems and the presence of keloids in patients with black skin. Method. This case-control study was conducted between September 2007 and August 2011 comparing dermatologic outpatients with keloids to matched controls recruited in preanesthetic consultation at Tokoin Teaching Hospital of Lomé (Togo). Results. The distribution of different ABO blood groups and Rhesus blood groups in both groups (cases versus controls) was not significantly different. This distribution of different blood groups was superimposed on the general population of blood donors at the National Blood Transfusion Center of Lomé. Univariate analysis between each blood group and the presence of keloid does not yield any statistically significant association between blood groups and presence of keloids in the subjects. Conclusion. The study shows no significant association between blood groups and the presence of keloids in our patients. Further investigation needs to be conducted to elucidate this hypothesis further by conducting multicenter studies of several ethnic groups.
Relation of pediatric blood lead levels to lead in gasoline.
Billick, I H; Curran, A S; Shier, D R
1980-01-01
Analysis of a large data set of pediatric blood lead levels collected in New York City (1970-1976) shows a highly significant association between geometric mean blood lead levels and the amount of lead present in gasoline sold during the same period. This association was observed for all age and ethnic groups studied, and it suggests that possible exposure pathways other than ambient air should be considered. Even without detailed knowledge of the exact exposure pathways, sufficient information now exists for policy analysis and decisions relevant to controls and standards related to lead in gasoline and its effect on subsets of the population. PMID:7389685
Discriminant Analysis of Raman Spectra for Body Fluid Identification for Forensic Purposes
Sikirzhytski, Vitali; Virkler, Kelly; Lednev, Igor K.
2010-01-01
Detection and identification of blood, semen and saliva stains, the most common body fluids encountered at a crime scene, are very important aspects of forensic science today. This study targets the development of a nondestructive, confirmatory method for body fluid identification based on Raman spectroscopy coupled with advanced statistical analysis. Dry traces of blood, semen and saliva obtained from multiple donors were probed using a confocal Raman microscope with a 785-nm excitation wavelength under controlled laboratory conditions. Results demonstrated the capability of Raman spectroscopy to identify an unknown substance to be semen, blood or saliva with high confidence. PMID:22319277
This compendium includes method summaries provided by the Centers for Disease Control and Prevention/National Center for Environmental Health (CDC/NCEH) for the collection and shipping of blood and urine samples for analysis of metals and volatile organic compounds (VOCs). The pr...
NASA Astrophysics Data System (ADS)
Ostrowski, Z.; Melka, B.; Adamczyk, W.; Rojczyk, M.; Golda, A.; Nowak, A. J.
2016-09-01
In the research a numerical Computational Fluid Dynamics (CFD) model of the pulsatile blood flow was created and analyzed. A real geometry of aorta and its thoracic branches of 8-year old patient diagnosed with a congenital heart defect - coarctation of aorta was used. The inlet boundary condition were implemented as the User Define Function according to measured values of volumetric blood flow. The blood flow was treated as multiphase: plasma, set as the primary fluid phase, was dominant with volume fraction of 0.585 and morphological elements of blood were treated in Euler-Euler approach as dispersed phases (with 90% Red Blood Cells and White Blood Cells as remaining solid volume fraction).
Barreto, Savio G; Singh, Amanjeet; Perwaiz, Azhar; Singh, Tanveer; Singh, Manish Kumar; Chaudhary, Adarsh
2017-04-01
Unnecessary preoperative ordering of blood and blood products results in wastage of a valuable life-saving resource and poses a significant financial burden on healthcare systems. To determine patient-specific factors associated with intra-operative transfusions, and if intra-operative blood transfusions impact postoperative morbidity. Analysis of consecutive patients undergoing pancreatoduodenectomy (PD) for pancreatic tumors. A total of 384 patients underwent a classical PD with an estimated median blood loss of 200 cc and percentage transfused being 9.6%. Pre-existing hypertension, synchronous vascular resection, end-to-side pancreaticojejunostomy and nodal disease burden significantly associated with the need for intra-operative transfusions. Intra-operative blood transfusion not associated with postoperative morbidity. Optimization of MSBOS protocols for PD is required for more judicious use of blood products.
Er, Tze-Kiong; Kan, Tzu-Min; Su, Yu-Fa; Liu, Ta-Chih; Chang, Jan-Gowth; Hung, Shih-Ya; Jong, Yuh-Jyh
2012-11-12
Spinal muscular atrophy (SMA) is a neurodegenerative disease with the leading genetic cause of infant mortality. More than 95% of patients with SMA have a homozygous disruption in the survival motor neuron1 (SMN1) gene, caused by mutation, deletion, or rearrangement. Recently, treatment in humans in the immediate postnatal period, prior to the development of weakness or very early in the course of the disease, may be effective. Therefore, our objective was to establish a feasible method for SMA screening. High-resolution melting (HRM) analysis is rapidly becoming the most important mutation-scanning methodology that allows mutation scanning and genotyping without the need for costly labeled oligonucleotides. In the current study, we aim to develop a method for identifying the substitution of single nucleotide in SMN1 exon 7 (c.840C>T) by HRM analysis. Genomic DNA was extracted from peripheral blood samples and dried blood spots obtained from 30 patients with SMA and 30 normal individuals. All results were previously confirmed by denaturing high-performance liquid chromatography (DHPLC). In order to identify the substitution of single nucleotide in SMN1 exon 7 (c.840C>T) by HRM analysis, a primer set was used in HRM analysis. At first, we failed to identify the substitution of single nucleotide in SMN1 exon 7 (c.840C>T) by HRM analysis because the homozygous CC and homozygous TT cannot be distinguished by HRM analysis. Therefore, all samples were mixed with a known SMN1/SMN2 copy number (SMN1/SMN2=0:3), which we may call driver. This strategy is used to differentiate between homozygous CC and homozygous TT. After mixing with driver, the melting profile of homozygous CC becomes heteroduplex; however, the homozygous TT remains the same in the normalized and temperature-shifted difference plots. HRM analysis can be successfully applied to screen SMA via DNA obtained from whole blood and dried blood spots. We strongly believe that HRM analysis, a high-throughput method, could be used for identifying affected infants prior to the presentation of clinical symptoms in future. Copyright © 2012 Elsevier B.V. All rights reserved.
Blood serotonin levels in autism spectrum disorder: a systematic review and meta-analysis.
Gabriele, Stefano; Sacco, Roberto; Persico, Antonio M
2014-06-01
Elevated blood serotonin (5-HT) levels were the first biomarker identified in autism research. Many studies have contrasted blood 5-HT levels in autistic patients and controls, but different measurement protocols, technologies, and biomaterials have been used through the years. We performed a systematic review and meta-analysis to provide an overall estimate of effect size and between-study heterogeneity, while verifying whether and to what extent different methodological approaches influence the strength of this association. Our literature search strategy identified 551 papers, from which 22 studies providing patient and control blood 5-HT values were selected for meta-analysis. Significantly higher 5-HT levels in autistic patients compared to controls were recorded both in whole blood (WB) [O.R.=4.6; (3.1-5.2); P=1.0×10(-12]), and in platelet-rich plasma (PRP) [O.R.=2.6 (1.8-3.9); P=2.7×10(-7)]. Predictably, studies measuring 5-HT levels in platelet-poor plasma (PPP) yielded no significant group difference [O.R.=0.54 (0.2-2-0); P=0.36]. Altogether, elevated 5-HT blood levels were recorded in 28.3% in WB and 22.5% in PRP samples of autistic individuals, as reported in 15 and 4 studies, respectively. Studies employing HPLC vs fluorometric assays yield similar cumulative effect sizes, but the former display much lower variability. In summary, despite some limitations mainly due to small study sample sizes, our results significantly reinforce the reliability of elevated 5-HT blood levels as a biomarker in ASD, providing practical indications potentially useful for its inclusion in multi-marker diagnostic panels for clinical use. Copyright © 2014 Elsevier B.V. and ECNP. All rights reserved.
Lahoz-Beneytez, Julio; Elemans, Marjet; Zhang, Yan; Ahmed, Raya; Salam, Arafa; Block, Michael; Niederalt, Christoph; Asquith, Becca; Macallan, Derek
2016-06-30
Human neutrophils have traditionally been thought to have a short half-life in blood; estimates vary from 4 to 18 hours. This dogma was recently challenged by stable isotope labeling studies with heavy water, which yielded estimates in excess of 3 days. To investigate this disparity, we generated new stable isotope labeling data in healthy adult subjects using both heavy water (n = 4) and deuterium-labeled glucose (n = 9), a compound with more rapid labeling kinetics. To interpret results, we developed a novel mechanistic model and applied it to previously published (n = 5) and newly generated data. We initially constrained the ratio of the blood neutrophil pool to the marrow precursor pool (ratio = 0.26; from published values). Analysis of heavy water data sets yielded turnover rates consistent with a short blood half-life, but parameters, particularly marrow transit time, were poorly defined. Analysis of glucose-labeling data yielded more precise estimates of half-life (0.79 ± 0.25 days; 19 hours) and marrow transit time (5.80 ± 0.42 days). Substitution of this marrow transit time in the heavy water analysis gave a better-defined blood half-life of 0.77 ± 0.14 days (18.5 hours), close to glucose-derived values. Allowing the ratio of blood neutrophils to mitotic neutrophil precursors (R) to vary yielded a best-fit value of 0.19. Reanalysis of the previously published model and data also revealed the origin of their long estimates for neutrophil half-life: an implicit assumption that R is very large, which is physiologically untenable. We conclude that stable isotope labeling in healthy humans is consistent with a blood neutrophil half-life of less than 1 day. © 2016 by The American Society of Hematology.
Transcriptomics analysis of lungs and peripheral blood of crystalline silica-exposed rats
Sellamuthu, Rajendran; Umbright, Christina; Roberts, Jenny R.; Chapman, Rebecca; Young, Shih-Houng; Richardson, Diana; Cumpston, Jared; McKinney, Walter; Chen, Bean T.; Frazer, David; Li, Shengqiao; Kashon, Michael; Joseph, Pius
2015-01-01
Minimally invasive approaches to detect/predict target organ toxicity have significant practical applications in occupational toxicology. The potential application of peripheral blood transcriptomics as a practical approach to study the mechanisms of silica-induced pulmonary toxicity was investigated. Rats were exposed by inhalation to crystalline silica (15 mg/m3, 6 h/day, 5 days) and pulmonary toxicity and global gene expression profiles of lungs and peripheral blood were determined at 32 weeks following termination of exposure. A significant elevation in bronchoalveolar lavage fluid lactate dehydrogenase activity and moderate histological changes in the lungs, including type II pneumocyte hyperplasia and fibrosis, indicated pulmonary toxicity in the rats. Similarly, significant infiltration of neutrophils and elevated monocyte chemotactic protein-1 levels in the lungs showed pulmonary inflammation in the rats. Microarray analysis of global gene expression profiles identified significant differential expression [>1.5-fold change and false discovery rate (FDR) p < 0.01] of 520 and 537 genes, respectively, in the lungs and blood of the exposed rats. Bioinformatics analysis of the differentially expressed genes demonstrated significant similarity in the biological processes, molecular networks, and canonical pathways enriched by silica exposure in the lungs and blood of the rats. Several genes involved in functions relevant to silica-induced pulmonary toxicity such as inflammation, respiratory diseases, cancer, cellular movement, fibrosis, etc, were found significantly differentially expressed in the lungs and blood of the silica-exposed rats. The results of this study suggested the potential application of peripheral blood gene expression profiling as a toxicologically relevant and minimally invasive surrogate approach to study the mechanisms underlying silica-induced pulmonary toxicity. PMID:22861000
Kawana, Shuichi; Nakagawa, Katsuhiro; Hasegawa, Yuki; Yamaguchi, Seiji
2010-11-15
A simple and rapid method for quantitative analysis of amino acids, including valine (Val), leucine (Leu), isoleucine (Ile), methionine (Met) and phenylalanine (Phe), in whole blood has been developed using GC/MS. In this method, whole blood was collected using a filter paper technique, and a 1/8 in. blood spot punch was used for sample preparation. Amino acids were extracted from the sample, and the extracts were purified using cation-exchange resins. The isotope dilution method using ²H₈-Val, ²H₃-Leu, ²H₃-Met and ²H₅-Phe as internal standards was applied. Following propyl chloroformate derivatization, the derivatives were analyzed using fast-GC/MS. The extraction recoveries using these techniques ranged from 69.8% to 87.9%, and analysis time for each sample was approximately 26 min. Calibration curves at concentrations from 0.0 to 1666.7 μmol/l for Val, Leu, Ile and Phe and from 0.0 to 333.3 μmol/l for Met showed good linearity with regression coefficients=1. The method detection limits for Val, Leu, Ile, Met and Phe were 24.2, 16.7, 8.7, 1.5 and 12.9 μmol/l, respectively. This method was applied to blood spot samples obtained from patients with phenylketonuria (PKU), maple syrup urine disease (MSUD), hypermethionine and neonatal intrahepatic cholestasis caused by citrin deficiency (NICCD), and the analysis results showed that the concentrations of amino acids that characterize these diseases were increased. These results indicate that this method provides a simple and rapid procedure for precise determination of amino acids in whole blood. Copyright © 2010 Elsevier B.V. All rights reserved.
Unbiased Characterization of Anopheles Mosquito Blood Meals by Targeted High-Throughput Sequencing
Logue, Kyle; Keven, John Bosco; Cannon, Matthew V.; Reimer, Lisa; Siba, Peter; Walker, Edward D.; Zimmerman, Peter A.; Serre, David
2016-01-01
Understanding mosquito host choice is important for assessing vector competence or identifying disease reservoirs. Unfortunately, the availability of an unbiased method for comprehensively evaluating the composition of insect blood meals is very limited, as most current molecular assays only test for the presence of a few pre-selected species. These approaches also have limited ability to identify the presence of multiple mammalian hosts in a single blood meal. Here, we describe a novel high-throughput sequencing method that enables analysis of 96 mosquitoes simultaneously and provides a comprehensive and quantitative perspective on the composition of each blood meal. We validated in silico that universal primers targeting the mammalian mitochondrial 16S ribosomal RNA genes (16S rRNA) should amplify more than 95% of the mammalian 16S rRNA sequences present in the NCBI nucleotide database. We applied this method to 442 female Anopheles punctulatus s. l. mosquitoes collected in Papua New Guinea (PNG). While human (52.9%), dog (15.8%) and pig (29.2%) were the most common hosts identified in our study, we also detected DNA from mice, one marsupial species and two bat species. Our analyses also revealed that 16.3% of the mosquitoes fed on more than one host. Analysis of the human mitochondrial hypervariable region I in 102 human blood meals showed that 5 (4.9%) of the mosquitoes unambiguously fed on more than one person. Overall, analysis of PNG mosquitoes illustrates the potential of this approach to identify unsuspected hosts and characterize mixed blood meals, and shows how this approach can be adapted to evaluate inter-individual variations among human blood meals. Furthermore, this approach can be applied to any disease-transmitting arthropod and can be easily customized to investigate non-mammalian host sources. PMID:26963245
Taing, Kevin Y; Farkouh, Michael E; Moineddin, Rahim; Tu, Jack V; Jha, Prabhat
2017-01-01
The utility of bioelectrical impedance analysis (BIA) derived adiposity measures as compared to anthropometric measures for the assessment of adiposity-related health risk is not clear. We aimed to clarify the relationships of BIA and anthropometric derived adipose measures with blood pressure and hypertension, and to compare the discriminative ability of the respective measures for hypertension. We used baseline data collected between 2015 and 2016 from the Indian Study on Health of Adults (ISHA), an ongoing population based cohort study in India ( N = 5990; age 30-69 years). We examined and compared the associations and discriminative ability between anthropometric (body mass index, waist circumference, hip circumference, waist-hip ratio, waist-height ratio) and BIA (whole body and trunk fat percentage) derived adiposity measures with blood pressure components (systolic pressure, diastolic pressure, pulse pressure, mean arterial pressure, mid-blood pressure) and hypertension. Regardless of whether the adiposity measure was derived from BIA or anthropometry, all were strongly and positively associated with blood pressure and hypertension. For both men and women, the magnitude of association of BIA measures with blood pressure and hypertension were comparable to those of anthropometric measures. Further, the ability of BIA derived adiposity measures to distinguish between those with and without hypertension was similar to the discriminative ability of anthropometric measures. As compared to simple anthropometric measures, BIA derived estimates of adiposity provide no apparent advantage in the assessment of blood pressure and hypertension. The observed similarities between adiposity measures suggest that simple anthropometrics may be sufficient to assess adiposity and adiposity-related risks.
Cesana, Giancarlo; Sega, Roberto; Ferrario, Marco; Chiodini, Paolo; Corrao, Giovanni; Mancia, Giuseppe
2003-01-01
The extent to which psychosocial stress concurs to raise blood pressure is still uncertain. Here the association between job strain and office blood pressure in a pooled analysis of four population samples from northern Italy is assessed. Four surveys assessing prevalence of major coronary risk factors were performed in 1986, 1990, 1991, and 1993 in area "Brianza" (Milan), a World Health Organization-MONItoring cardiovascular disease (WHO-MONICA) Project collaborating center. Ten year age- and gender-stratified independent samples were randomly recruited from the 25- to 64-year-old residents. The methods used to assess coronary risk factors strictly adhered to the MONICA manual, were kept constant, and underwent internal and external quality controls. Job strain was investigated through the administration to employed participants of a questionnaire derived from the Karasek model, assessing job demand/control latitude. Analysis was restricted to 25- to 54-year-old participants, untreated for hypertension (1799 men and 1010 women). Among men, there was a 3 mm Hg increase of systolic blood pressure (p<.001) moving from low to high strain job categories. This difference was independent from age, education, body mass index, alcohol intake, smoking habits, leisure time physical activity, and survey. No relevant differences among job strain categories were found in women and for diastolic blood pressure in both gender groups. These results carried out on a large population-based sample confirm previous findings obtained adopting ambulatory blood pressure measurements in more restricted samples of population or patients. Further research is needed to clarify the relationship between perceived work stress and blood pressure in women.
Villa, C A; Finlayson, S; Limpus, C; Gaus, C
2015-04-15
Biomonitoring of blood is commonly used to identify and quantify occupational or environmental exposure to chemical contaminants. Increasingly, this technique has been applied to wildlife contaminant monitoring, including for green turtles, allowing for the non-lethal evaluation of chemical exposure in their nearshore environment. The sources, composition, bioavailability and toxicity of metals in the marine environment are, however, often unknown and influenced by numerous biotic and abiotic factors. These factors can vary considerably across time and space making the selection of the most informative elements for biomonitoring challenging. This study aimed to validate an ICP-MS multi-element screening method for green turtle blood in order to identify and facilitate prioritisation of target metals for subsequent fully quantitative analysis. Multi-element screening provided semiquantitative results for 70 elements, 28 of which were also determined through fully quantitative analysis. Of the 28 comparable elements, 23 of the semiquantitative results had an accuracy between 67% and 112% relative to the fully quantified values. In lieu of any available turtle certified reference materials (CRMs), we evaluated the use of human blood CRMs as a matrix surrogate for quality control, and compared two commonly used sample preparation methods for matrix related effects. The results demonstrate that human blood provides an appropriate matrix for use as a quality control material in the fully quantitative analysis of metals in turtle blood. An example for the application of this screening method is provided by comparing screening results from blood of green turtles foraging in an urban and rural region in Queensland, Australia. Potential targets for future metal biomonitoring in these regions were identified by this approach. Copyright © 2014 Elsevier B.V. All rights reserved.
Fischer, John P; Nelson, Jonas A; Sieber, Brady; Stransky, Carrie; Kovach, Stephen J; Serletti, Joseph M; Wu, Liza C
2014-05-01
Free tissue transfer requires lengthy operative times and can be associated with significant blood loss. The goal of our study was to determine independent risk factors for blood transfusions and transfusion-related complications and costs. We reviewed our prospectively maintained free flap database and identified all patients undergoing breast reconstruction receiving blood transfusions. These patients were compared with those not receiving a postoperative transfusion. We examined baseline patient comorbidities, preoperative and postoperative hemoglobin (HgB) levels, intraoperative and postoperative complications, and blood transfusions. Factors associated with transfusion were identified using univariate analyses, and multivariate logistic regression was used to determine independently associated factors. A total of 70 (8.2%) patients received postoperative blood transfusions. Multivariate analysis revealed associations between length of surgery (P=0.01), intraoperative arterial thrombosis [odds ratio (OR), 6.75; P=0.01], major surgical complications (OR, 25.9; P<0.001), medical complications (OR, 7.2; P=0.002), and postoperative HgB levels (OR, 0.2; P<0.001). Transfusions were independently associated with higher rates of medical complications (OR, 2.7; P=0.03). A significantly lower rate of medical complications was observed when a restrictive transfusion (HgB level, <7 g/dL) was administered (P=0.04). A cost analysis demonstrated that each blood transfusion was independently associated with an added $1,500 in total cost. Several key perioperative factors are associated with allogenic transfusion, including intraoperative complications, operative time, HgB level, and postoperative medical and surgical complications. Blood transfusions were independently associated with greater morbidity and added hospital costs. Overall, a restrictive transfusion strategy (HgB level, <7 g/dL or clinically symptomatic) may help minimize medical complications. Prognostic/risk category, level III.
Mi, Bobin; Liu, Guohui; Lv, Huijuan; Liu, Yi; Zha, Kun; Wu, Qipeng; Liu, Jing
2017-04-18
Tranexamic acid (TXA) has been proven to be effective in reducing blood loss and transfusion rate after total knee arthroplasty (TKA) without increasing the risk of deep vein thrombosis (DVT) and pulmonary embolism (PE). Recently, an increasing number of studies have been interested in applying combined intravenous (IV) with intraarticular (IA) tranexamic acid in total knee arthroplasty. The purpose of this meta-analysis was to compare the blood loss and complications of combined TXA with IV TXA or IA TXA on TKA. Systematic search of literatures were conducted to identify related articles that were published in PubMed, MEDLINE, Embase, the Cochrane Library, SpringerLink, ClinicalTrials.gov, and Ovid from their inception to September 2016. All studies that compare blood loss and complications of combined TXA and IV TXA or IA TXA on TKA were included. Main outcomes were collected and analyzed by the Review Manager 5.3. Five studies were included in the present meta-analysis. There was significant difference in total blood loss and blood volume of drainage when compared combined TXA group with IV TXA group or IA TXA group (P < 0.05). There was no difference in transfusion rate and thromboembolic complications when comparing combined TXA with IV TXA or IA TXA alone (P > 0.05). Compared with administration of IA TXA or IV TXA alone on TKA, combined use of TXA has advantages in reducing total blood loss and blood volume of drainage without increasing the incidence of thromboembolic complications. We recommend combined TXA as the preferred option for patients undergoing TKA.
Jiang, Jiyang; Thalamuthu, Anbupalam; Ho, Jennifer E.; Mahajan, Anubha; Ek, Weronica E.; Brown, David A.; Breit, Samuel N.; Wang, Thomas J.; Gyllensten, Ulf; Chen, Ming-Huei; Enroth, Stefan; Januzzi, James L.; Lind, Lars; Armstrong, Nicola J.; Kwok, John B.; Schofield, Peter R.; Wen, Wei; Trollor, Julian N.; Johansson, Åsa; Morris, Andrew P.; Vasan, Ramachandran S.; Sachdev, Perminder S.; Mather, Karen A.
2018-01-01
Blood levels of growth differentiation factor-15 (GDF-15), also known as macrophage inhibitory cytokine-1 (MIC-1), have been associated with various pathological processes and diseases, including cardiovascular disease and cancer. Prior studies suggest genetic factors play a role in regulating blood MIC-1/GDF-15 concentration. In the current study, we conducted the largest genome-wide association study (GWAS) to date using a sample of ∼5,400 community-based Caucasian participants, to determine the genetic variants associated with MIC-1/GDF-15 blood concentration. Conditional and joint (COJO), gene-based association, and gene-set enrichment analyses were also carried out to identify novel loci, genes, and pathways. Consistent with prior results, a locus on chromosome 19, which includes nine single nucleotide polymorphisms (SNPs) (top SNP, rs888663, p = 1.690 × 10-35), was significantly associated with blood MIC-1/GDF-15 concentration, and explained 21.47% of its variance. COJO analysis showed evidence for two independent signals within this locus. Gene-based analysis confirmed the chromosome 19 locus association and in addition, a putative locus on chromosome 1. Gene-set enrichment analyses showed that the“COPI-mediated anterograde transport” gene-set was associated with MIC-1/GDF15 blood concentration with marginal significance after FDR correction (p = 0.067). In conclusion, a locus on chromosome 19 was associated with MIC-1/GDF-15 blood concentration with genome-wide significance, with evidence for a new locus (chromosome 1). Future studies using independent cohorts are needed to confirm the observed associations especially for the chromosomes 1 locus, and to further investigate and identify the causal SNPs that contribute to MIC-1/GDF-15 levels. PMID:29628937
Jiang, Jiyang; Thalamuthu, Anbupalam; Ho, Jennifer E; Mahajan, Anubha; Ek, Weronica E; Brown, David A; Breit, Samuel N; Wang, Thomas J; Gyllensten, Ulf; Chen, Ming-Huei; Enroth, Stefan; Januzzi, James L; Lind, Lars; Armstrong, Nicola J; Kwok, John B; Schofield, Peter R; Wen, Wei; Trollor, Julian N; Johansson, Åsa; Morris, Andrew P; Vasan, Ramachandran S; Sachdev, Perminder S; Mather, Karen A
2018-01-01
Blood levels of growth differentiation factor-15 (GDF-15), also known as macrophage inhibitory cytokine-1 (MIC-1), have been associated with various pathological processes and diseases, including cardiovascular disease and cancer. Prior studies suggest genetic factors play a role in regulating blood MIC-1/GDF-15 concentration. In the current study, we conducted the largest genome-wide association study (GWAS) to date using a sample of ∼5,400 community-based Caucasian participants, to determine the genetic variants associated with MIC-1/GDF-15 blood concentration. Conditional and joint (COJO), gene-based association, and gene-set enrichment analyses were also carried out to identify novel loci, genes, and pathways. Consistent with prior results, a locus on chromosome 19, which includes nine single nucleotide polymorphisms (SNPs) (top SNP, rs888663, p = 1.690 × 10 -35 ), was significantly associated with blood MIC-1/GDF-15 concentration, and explained 21.47% of its variance. COJO analysis showed evidence for two independent signals within this locus. Gene-based analysis confirmed the chromosome 19 locus association and in addition, a putative locus on chromosome 1. Gene-set enrichment analyses showed that the"COPI-mediated anterograde transport" gene-set was associated with MIC-1/GDF15 blood concentration with marginal significance after FDR correction ( p = 0.067). In conclusion, a locus on chromosome 19 was associated with MIC-1/GDF-15 blood concentration with genome-wide significance, with evidence for a new locus (chromosome 1). Future studies using independent cohorts are needed to confirm the observed associations especially for the chromosomes 1 locus, and to further investigate and identify the causal SNPs that contribute to MIC-1/GDF-15 levels.
Differences in iron concentration in whole blood of animal models using NAA
NASA Astrophysics Data System (ADS)
Bahovschi, V.; Zamboni, C. B.; Lopes Silva, L. F. F.; Metairon, S.; Medeiros, I. M. M. A.
2015-07-01
In this study Neutron Activation Analysis technique (NAA) was applied to determine Fe concentration in whole blood samples of several animal models such as: mice (Mus musculus), Golden Hamster (Mesocricetus auratus), Wistar rats, Albinic Rabbits of New Zealand, Golden Retriever dogs and Crioulabreed horses. These results were compared with human whole blood estimation to check their similarities.
Frequency of subgroups of the antigen “a” among volunteer donors
Parra-Jaramillo, Katherine; Chiriboga-Ponce, Rosa F
2018-01-01
The presence of weak variants of blood type A represents a challenge in the practice of immunohematology for discrepancies in the time of the classification. It is common in blood banks to perform a forward and reverse typing for the purpose of confirming the blood type, but not all the people with a subgroup A2 have developed anti-A1 antibodies. We present a descriptive, observational and transversal study that establishes the proportion of subgroups of A antigen with the analysis of manual tube technique and monoclonal antibodies like anti-A, anti-A1 (Dolichus biflorus lectins extract) and anti-H. The analysis involved a total of 818 samples of voluntary blood donor, selected by random sampling, which were initially classified as 737 of Type A, and 81 as Type AB, with a confidence level of 95% (alpha error of 5% and 3% of precision). The present study evaluated the existence of the subgroups A1, A2, A1B, A2B, A intermediate and A intB. It is recommended the identification of subgroups in different types of blood in the laboratory and blood banks. Copyright: © 2018 SecretarÍa de Salud
Ghata, Narugopal; Aldredge, Ralph C.; Bec, Julien; Marcu, Laura
2015-01-01
SUMMARY Optical techniques including fluorescence lifetime spectroscopy have demonstrated potential as a tool for study and diagnosis of arterial vessel pathologies. However, their application in the intravascular diagnostic procedures has been hampered by the presence of blood hemoglobin that affects the light delivery to and the collection from the vessel wall. We report a computational fluid dynamics model that allows for the optimization of blood flushing parameters in a manner that minimizes the amount of saline needed to clear the optical field of view and reduces any adverse effects caused by the external saline jet. A 3D turbulence (k−ω) model was employed for Eulerian–Eulerian two-phase flow to simulate the flow inside and around a side-viewing fiber-optic catheter. Current analysis demonstrates the effects of various parameters including infusion and blood flow rates, vessel diameters, and pulsatile nature of blood flow on the flow structure around the catheter tip. The results from this study can be utilized in determining the optimal flushing rate for given vessel diameter, blood flow rate, and maximum wall shear stress that the vessel wall can sustain and subsequently in optimizing the design parameters of optical-based intravascular catheters. PMID:24953876
Das De, Tanwee; Thomas, Tina; Verma, Sonia; Singla, Deepak; Chauhan, Charu; Srivastava, Vartika; Sharma, Punita; Kumari, Seena; Tevatiya, Sanjay; Rani, Jyoti; Hasija, Yasha; Pandey, Kailash C; Dixit, Rajnikant
2018-01-01
Decoding the molecular basis of host seeking and blood feeding behavioral evolution/adaptation in the adult female mosquitoes may provide an opportunity to design new molecular strategy to disrupt human-mosquito interactions. Although there is a great progress in the field of mosquito olfaction and chemo-detection, little is known about the sex-specific evolution of the specialized olfactory system of adult female mosquitoes that enables them to drive and manage the complex blood-feeding associated behavioral responses. A comprehensive RNA-Seq analysis of prior and post blood meal olfactory system of An. culicifacies mosquito revealed a minor but unique change in the nature and regulation of key olfactory genes that may play a pivotal role in managing diverse behavioral responses. Based on age-dependent transcriptional profiling, we further demonstrated that adult female mosquito's chemosensory system gradually learned and matured to drive the host-seeking and blood feeding behavior at the age of 5-6 days. A time scale expression analysis of Odorant Binding Proteins (OBPs) unravels unique association with a late evening to midnight peak biting time. Blood meal-induced switching of unique sets of OBP genes and Odorant Receptors (Ors) expression coincides with the change in the innate physiological status of the mosquitoes. Blood meal follows up experiments further provide enough evidence that how a synergistic and concurrent action of OBPs-Ors may drive "prior and post blood meal" associated complex behavioral events. A dominant expression of two sensory appendages proteins (SAP-1 & SAP2) in the legs of An. culicifacies suggests that this mosquito species may draw an extra advantage of having more sensitive appendages than An. stephensi , an urban malarial vector in the Indian subcontinents. Finally, our molecular modeling analysis predicts crucial amino acid residues for future functional characterization of the sensory appendages proteins which may play a central role in regulating multiple behaviors of An. culicifacies mosquito. SIGNIFICANCE Evolution and adaptation of blood feeding behavior not only favored the reproductive success of adult female mosquitoes but also make them important disease-transmitting vectors. An environmental exposure after emergence may favor the broadly tuned olfactory system of mosquitoes to drive complex behavioral responses. But, how these olfactory derived genetic factors manage female specific "pre and post" blood meal associated complex behavioral responses are not well known. Our findings suggest that a synergistic action of olfactory factors may govern an innate to prime learning strategy to facilitate rapid blood meal acquisition and downstream behavioral activities. A species-specific transcriptional profiling and an in-silico analysis predict that "sensory appendages protein" may be a unique target to design disorientation strategy against the mosquito Anopheles culicifacies .
Hodnett, Darragh; Wood, David M; Raja, Kishor; Dargan, Paul I; Shah, Anoop D
2012-02-01
The trace elements cobalt (Co), chromium (Cr), manganese (Mn) and nickel (Ni) are normally present at low concentrations in blood. There has been a concern that stainless steel venepuncture needles typically used for collection of blood samples may contaminate these samples, leading to the masking of deficiency states or causing potential clinical confusion as to whether an individual has a "toxic" concentration. To determine whether there is any difference between the concentrations of the trace elements obtained by different methods of blood sampling. We took blood samples using a standard venepuncture needle, a "butterfly" winged infusion needle (three consecutive samples) and a plastic intravenous cannula (three consecutive samples) from 10 healthy volunteers. We measured the concentrations of Co, Cr, Mn and Ni in the samples using Inductively Coupled Plasma Mass Spectrometry, and used analysis of variance (ANOVA) to investigate if there was any difference between the methods of blood sampling. The mean ± standard deviation blood metal concentrations were: Co 0.33 ± 0.2 μg/l, Cr 2.43 ± 1.55 μg/l, Mn 8.07 ± 7.74 μg/l and Ni 10.4 ± 4.69 μg/l. There was considerable variation between blood metal concentrations of individual subjects and a few sporadic high values. By ANOVA, there was no significant difference between the metal concentrations measured using different methods of blood collection. It is not necessary to routinely use a plastic cannula for blood sampling for trace element analysis. However, it is possible that sporadic contamination due to stainless steel needles may occur, so we would recommend that unexpected high concentrations are verified by taking a second sample taken through a plastic cannula.
Delaney, Meghan; Harris, Samantha; Haile, Askale; Johnsen, Jill; Teramura, Gayle; Nelson, Karen
2015-10-01
There has yet to be a comprehensive analysis of blood group antigen prevalence in Asian Americans and Native Americans. There may be ethnic differences in blood group frequencies that would result in clinically important mismatches through transfusion. Blood donors who self-identified as Asian or Native American were tested using a single-nucleotide polymorphism (SNP) DNA array (HEA BeadChip kit, Bioarray Solutions Ltd) that predicts expression of 38 human erythrocyte antigens (HEAs) and by serology for ABO, D, C, M, N, Jk(a) , and Jk(b) . The prevalence of blood group antigens was compared to published European prevalence. Discrepancies between SNP-predicted and serology-detected antigens were tallied. A total of 9087 blood donors were tested from nine Asian and Native American heritages. The predicted prevalence of selected antigens in the RHCE, JK, FY, MNS, LU, CO, and DO blood group systems were variable between Asian populations, but overall not significantly different than Europeans. Compared to European frequencies, Kell blood group allele frequencies were significantly different in the Chinese, Native American, Hawaiian/Pacific Islander, South Asian, and Southeast Asian heritage blood donors; Diego antigens Di(a) and Di(b) were different in donors of Native American and South Asian ancestries (p < 0.05). Of the donors tested, 4.5% showed a SNP-serology discrepancy that segregated within specific ethnic groups. This study provides HEA allele frequency and antigen prevalence data in a cohort of Asian and Native Americans donors. Several ethnic groups exhibited differences in HEA frequencies compared to Europeans. Genotype-serotype discrepancies were detected in all systems studied. © 2015 AABB.
Franceschini, Nora; Carty, Cara L; Lu, Yingchang; Tao, Ran; Sung, Yun Ju; Manichaikul, Ani; Haessler, Jeff; Fornage, Myriam; Schwander, Karen; Zubair, Niha; Bien, Stephanie; Hindorff, Lucia A; Guo, Xiuqing; Bielinski, Suzette J; Ehret, Georg; Kaufman, Joel D; Rich, Stephen S; Carlson, Christopher S; Bottinger, Erwin P; North, Kari E; Rao, D C; Chakravarti, Aravinda; Barrett, Paula Q; Loos, Ruth J F; Buyske, Steven; Kooperberg, Charles
2016-01-01
Despite the substantial burden of hypertension in US minority populations, few genetic studies of blood pressure have been conducted in Hispanics and African Americans, and it is unclear whether many of the established loci identified in European-descent populations contribute to blood pressure variation in non-European descent populations. Using the Metabochip array, we sought to characterize the genetic architecture of previously identified blood pressure loci, and identify novel cardiometabolic variants related to systolic and diastolic blood pressure in a multi-ethnic US population including Hispanics (n = 19,706) and African Americans (n = 18,744). Several known blood pressure loci replicated in African Americans and Hispanics. Fourteen variants in three loci (KCNK3, FGF5, ATXN2-SH2B3) were significantly associated with blood pressure in Hispanics. The most significant diastolic blood pressure variant identified in our analysis, rs2586886/KCNK3 (P = 5.2 x 10-9), also replicated in independent Hispanic and European-descent samples. African American and trans-ethnic meta-analysis data identified novel variants in the FGF5, ULK4 and HOXA-EVX1 loci, which have not been previously associated with blood pressure traits. Our identification and independent replication of variants in KCNK3, a gene implicated in primary hyperaldosteronism, as well as a variant in HOTTIP (HOXA-EVX1) suggest that further work to clarify the roles of these genes may be warranted. Overall, our findings suggest that loci identified in European descent populations also contribute to blood pressure variation in diverse populations including Hispanics and African Americans-populations that are understudied for hypertension genetic risk factors.
Ralston, J D; Cook, A J; Anderson, M L; Catz, S L; Fishman, P A; Carlson, J; Johnson, R; Green, B B
2014-01-01
We evaluated the role of home monitoring, communication with pharmacists, medication intensification, medication adherence and lifestyle factors in contributing to the effectiveness of an intervention to improve blood pressure control in patients with uncontrolled essential hypertension. We performed a mediation analysis of a published randomized trial based on the Chronic Care Model delivered over a secure patient website from June 2005 to December 2007. Study arms analyzed included usual care with a home blood pressure monitor and usual care with home blood pressure monitor and web-based pharmacist care. Mediator measures included secure messaging and telephone encounters; home blood pressure monitoring; medications intensification and adherence and lifestyle factors. Overall fidelity to the Chronic Care Model was assessed with the Patient Assessment of Chronic Care (PACIC) instrument. The primary outcome was percent of participants with blood pressure (BP) <140/90 mm Hg. At 12 months follow-up, patients in the web-based pharmacist care group were more likely to have BP <140/90 mm Hg (55%) compared to patients in the group with home blood pressure monitors only (37%) (p = 0.001). Home blood pressure monitoring accounted for 30.3% of the intervention effect, secure electronic messaging accounted for 96%, and medication intensification for 29.3%. Medication adherence and self-report of fruit and vegetable intake and weight change were not different between the two study groups. The PACIC score accounted for 22.0 % of the main intervention effect. The effect of web-based pharmacist care on improved blood pressure control was explained in part through a combination of home blood pressure monitoring, secure messaging, and antihypertensive medication intensification.
Muhihi, Alfa J; Njelekela, Marina A; Mpembeni, Rose N M; Muhihi, Bikolimana G; Anaeli, Amani; Chillo, Omary; Kubhoja, Sulende; Lujani, Benjamin; Maghembe, Mwanamkuu; Ngarashi, Davis
2018-02-13
Whilst the burden of non-communicable diseases is increasing in developing countries, little data is available on blood pressure among Tanzanian children. This study aimed at determining the blood pressure profiles and risk factors associated with elevated blood pressure among primary school children in Dar es Salaam, Tanzania. We conducted a cross sectional survey among 446 children aged 6-17 years from 9 randomly selected primary schools in Dar es Salaam. We measured blood pressure using a standardized digital blood pressure measuring machine (Omron Digital HEM-907, Tokyo, Japan). We used an average of the three blood pressure readings for analysis. Elevated blood pressure was defined as average systolic or diastolic blood pressure ≥ 90th percentile for age, gender and height. The proportion of children with elevated blood pressure was 15.2% (pre-hypertension 4.4% and hypertension 10.8%). No significant gender differences were observed in the prevalence of elevated BP. Increasing age and overweight/obese children were significantly associated with elevated BP (p = 0.0029 and p < 0.0001) respectively. Similar associations were observed for age and overweight/obesity with hypertension. (p = 0.0506 and p < 0.0001) respectively. In multivariate analysis, age above 10 years (adjusted RR = 3.63, 95% CI = 1.03-7.82) was significantly and independently associated with elevated BP in this population of school age children. We observed a higher proportion of elevated BP in this population of school age children. Older age and overweight/obesity were associated with elevated BP. Assessment of BP and BMI should be incorporated in school health program in Tanzania to identify those at risk so that appropriate interventions can be instituted before development of associated complications.
Nersesova, L S; Petrosian, M S; Gazariants, M G; Mkrtchian, Z S; Meliksetian, G O; Pogosian, L G; Akopian, Zh I
2014-01-01
The comparative analysis of the rat liver and blood serum creatine kinase, alanine aminotransferase, aspartate aminotransferase, alkaline phosphatase and purine nucleoside phosphorylase post-radiation activity levels after a total two-hour long single and fractional exposure of the animals to low-intensity 900 MHz frequency electromagnetic field showed that the most sensitive enzymes to the both schedules of radiation are the liver creatine kinase, as well as the blood serum creatine kinase and alkaline phosphatase. According to the comparative analysis of the dynamics of changes in the activity level of the liver and blood serum creatine kinase, alanine aminotransferase, aspartate aminotransferase and purine nucleoside phosphorylase, both single and fractional radiation schedules do not affect the permeability of a hepatocyte cell membrane, but rather cause changes in their energetic metabolism. The correlation analysis of the post-radiation activity level changes of the investigated enzymes did not reveal a clear relationship between them. The dynamics of post-radiation changes in the activity of investigated enzyme levels following a single and short-term fractional schedules of radiation did not differ essentially.
Sun, Yanhua; Gong, Bing; Yuan, Xin; Zheng, Zhe; Wang, Guyan; Chen, Guo; Zhou, Chenghui; Wang, Wei; Ji, Bingyang
2015-08-01
The benefits of minimized extracorporeal circulation (MECC) compared with conventional extracorporeal circulation (CECC) are still in debate. PubMed, EMBASE and the Cochrane Library were searched until November 10, 2014. After quality assessment, we chose a fixed-effects model when the trials showed low heterogeneity, otherwise a random-effects model was used. We performed univariate meta-regression and sensitivity analysis to search for the potential sources of heterogeneity. Cumulative meta-analysis was performed to access the evolution of outcome over time. 41 RCTs enrolling 3744 patients were included after independent article review by 2 authors. MECC significantly reduced atrial fibrillation (RR, 0.76; 95% CI, 0.66 to 0.89; P < 0.001; I2 = 0%), and myocardial infarction (RR, 0.43; 95% CI, 0.26 to 0.71; P = 0.001; I2 = 0%). In addition, the results regarding chest tube drainage, transfusion rate, blood loss, red blood cell transfusion volume, and platelet count favored MECC as well. MECC diminished morbidity of cardiovascular complications postoperatively, conserved blood cells, and reduced allogeneic blood transfusion.
IB-LBM simulation of the haemocyte dynamics in a stenotic capillary.
Yuan-Qing, Xu; Xiao-Ying, Tang; Fang-Bao, Tian; Yu-Hua, Peng; Yong, Xu; Yan-Jun, Zeng
2014-01-01
To study the behaviour of a haemocyte when crossing a stenotic capillary, the immersed boundary-lattice Boltzmann method was used to establish a quantitative analysis model. The haemocyte was assumed to be spherical and to have an elastic cell membrane, which can be driven by blood flow to adopt a highly deformable character. In the stenotic capillary, the spherical blood cell was stressed both by the flow and the wall dimension, and the cell shape was forced to be stretched to cross the stenosis. Our simulation investigated the haemocyte crossing process in detail. The velocity and pressure were anatomised to obtain information on how blood flows through a capillary and to estimate the degree of cell damage caused by excessive pressure. Quantitative velocity analysis results demonstrated that a large haemocyte crossing a small stenosis would have a noticeable effect on blood flow, while quantitative pressure distribution analysis results indicated that the crossing process would produce a special pressure distribution in the cell interior and to some extent a sudden change between the cell interior and the surrounding plasma.
Kamran, Mudassar; Byrne, James V
2015-09-01
C-arm flat detector computed tomography (FDCT) parenchymal blood volume (PBV) measurements allow assessment of cerebral haemodynamics in the neurointerventional suite. This paper explores the feasibility of C-arm computed tomography (CT) PBV imaging and the relationship between the C-arm CT PBV and the MR-PWI-derived cerebral blood volume (CBV) and cerebral blood flow (CBF) parameters in aneurysmal subarachnoid haemorrhage (SAH) patients developing delayed cerebral ischemia (DCI). Twenty-six patients with DCI following aneurysmal SAH underwent a research C-arm CT PBV scan using a biplane angiography system and contemporaneous MR-PWI scan as part of a prospective study. Quantitative whole-brain atlas-based volume-of-interest analysis in conjunction with Pearson correlation and Bland-Altman tests was performed to explore the agreement between C-arm CT PBV and MR-derived CBV and CBF measurements. All patients received medical management, while eight patients (31%) underwent selective intra-arterial chemical angioplasty. Colour-coded C-arm CT PBV maps were 91% sensitive and 100% specific in detecting the perfusion abnormalities. C-arm CT rPBV demonstrated good agreement and strong correlation with both MR-rCBV and MR-rCBF measurements; the agreement and correlation were stronger for MR-rCBF relative to MR-rCBV and improved for C-arm CT PBV versus the geometric mean of MR-rCBV and MR-rCBF. Analysis of weighted means showed that the C-arm CT PBV has a preferential blood flow weighting (≈ 60% blood flow and ≈ 40% blood volume weighting). C-arm CT PBV imaging is feasible in DCI following aneurysmal SAH. PBV is a composite perfusion parameter incorporating both blood flow and blood volume weightings. That PBV has preferential (≈ 60%) blood flow weighting is an important finding, which is of clinical significance when interpreting the C-arm CT PBV maps, particularly in the setting of acute brain ischemia.
Christofaro, Diego G D; Farah, Breno Q; Vanderlei, Luiz Carlos M; Delfino, Leandro D; Tebar, William R; Barros, Mauro Virgílio G de; Ritti-Dias, Raphael M
High blood pressure is strongly associated with obesity in different populations. However, it is unclear whether different anthropometric indicators of obesity can satisfactorily predict high blood pressure in the school setting. This study evaluated the sensitivity and specificity of body mass index, waist circumference, and waist to height ratio in the detection of high blood pressure in adolescents. The sample consisted of 8295 adolescents aged 10-17 years. Weight was measured using a digital scale, height with a stadiometer, and waist circumference using a tape measure. Blood pressure was measured by an automatic blood pressure measuring device. ROC curves were used for the analysis of sensitivity and specificity of the three anthropometric indices in identifying high blood pressure. Binary Logistic Regression was used to assess the association of body mass index, waist circumference, and waist to height ratio with high blood pressure. Low values of sensitivity were observed for body mass index (0.35), waist circumference (0.37), and waist to height ratio (0.31) and high values of specificity for body mass index (0.86), waist circumference (0.82), and waist to height ratio (0.83) in the detection of high blood pressure. An association was observed between adolescents classified with high body mass index (OR=3.57 [95% CI=3.10-4.10]), waist cirumference (OR=3.24 [95% CI=2.83-3.72]), and waist to height ratio (OR=2.94 [95% CI=2.54-3.40]) with high blood pressure. Body mass index, waist circumference, and waist to height ratio presented low sensitivity to identify adolescents with high blood pressure. However, adolescents classified with high body mass index, waist circumference, and waist to height ratio demonstrated a high association of presenting high blood pressure. Copyright © 2017 Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia. Publicado por Elsevier Editora Ltda. All rights reserved.
Pimentel, Mark; Purdy, Chris; Magar, Raf; Rezaie, Ali
2016-07-01
A high incidence of irritable bowel syndrome (IBS) is associated with significant medical costs. Diarrhea-predominant IBS (IBS-D) is diagnosed on the basis of clinical presentation and diagnostic test results and procedures that exclude other conditions. This study was conducted to estimate the potential cost savings of a novel IBS diagnostic blood panel that tests for the presence of antibodies to cytolethal distending toxin B and anti-vinculin associated with IBS-D. A cost-minimization (CM) decision tree model was used to compare the costs of a novel IBS diagnostic blood panel pathway versus an exclusionary diagnostic pathway (ie, standard of care). The probability that patients proceed to treatment was modeled as a function of sensitivity, specificity, and likelihood ratios of the individual biomarker tests. One-way sensitivity analyses were performed for key variables, and a break-even analysis was performed for the pretest probability of IBS-D. Budget impact analysis of the CM model was extrapolated to a health plan with 1 million covered lives. The CM model (base-case) predicted $509 cost savings for the novel IBS diagnostic blood panel versus the exclusionary diagnostic pathway because of the avoidance of downstream testing (eg, colonoscopy, computed tomography scans). Sensitivity analysis indicated that an increase in both positive likelihood ratios modestly increased cost savings. Break-even analysis estimated that the pretest probability of disease would be 0.451 to attain cost neutrality. The budget impact analysis predicted a cost savings of $3,634,006 ($0.30 per member per month). The novel IBS diagnostic blood panel may yield significant cost savings by allowing patients to proceed to treatment earlier, thereby avoiding unnecessary testing. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.
Dolch, Michael E; Janitza, Silke; Boulesteix, Anne-Laure; Graßmann-Lichtenauer, Carola; Praun, Siegfried; Denzer, Wolfgang; Schelling, Gustav; Schubert, Sören
2016-12-01
Identification of microorganisms in positive blood cultures still relies on standard techniques such as Gram staining followed by culturing with definite microorganism identification. Alternatively, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry or the analysis of headspace volatile compound (VC) composition produced by cultures can help to differentiate between microorganisms under experimental conditions. This study assessed the efficacy of volatile compound based microorganism differentiation into Gram-negatives and -positives in unselected positive blood culture samples from patients. Headspace gas samples of positive blood culture samples were transferred to sterilized, sealed, and evacuated 20 ml glass vials and stored at -30 °C until batch analysis. Headspace gas VC content analysis was carried out via an auto sampler connected to an ion-molecule reaction mass spectrometer (IMR-MS). Measurements covered a mass range from 16 to 135 u including CO2, H2, N2, and O2. Prediction rules for microorganism identification based on VC composition were derived using a training data set and evaluated using a validation data set within a random split validation procedure. One-hundred-fifty-two aerobic samples growing 27 Gram-negatives, 106 Gram-positives, and 19 fungi and 130 anaerobic samples growing 37 Gram-negatives, 91 Gram-positives, and two fungi were analysed. In anaerobic samples, ten discriminators were identified by the random forest method allowing for bacteria differentiation into Gram-negative and -positive (error rate: 16.7 % in validation data set). For aerobic samples the error rate was not better than random. In anaerobic blood culture samples of patients IMR-MS based headspace VC composition analysis facilitates bacteria differentiation into Gram-negative and -positive.
Jodko, Daniel; Obidowski, Damian; Reorowicz, Piotr; Jóźwik, Krzysztof
2016-01-01
The aim of this study was to investigate the blood flow in the end-to-side arteriovenous (a-v) fistula, taking into account its pulsating nature and the patient-specific geometry of blood vessels. Computational Fluid Dynamics (CFD) methods were used for this analysis. DICOM images of the fistula, obtained from the angio-computed tomography, were a source of the data applied to develop a 3D geometrical model of the fistula. The model was meshed, then the ANSYS CFX v. 15.0 code was used to perform simulations of the flow in the vessels under analysis. Mesh independence tests were conducted. The non-Newtonian rheological model of blood and the Shear Stress Transport model of turbulence were employed. Blood vessel walls were assumed to be rigid. Flow patterns, velocity fields, the volume flow rate, the wall shear stress (WSS) propagation on particular blood vessel walls were shown versus time. The maximal value of the blood velocity was identified in the anastomosis - the place where the artery is connected to the vein. The flow rate was calculated for all veins receiving blood. The blood flow in the geometrically complicated a-v fistula was simulated. The values and oscillations of the WSS are the largest in the anastomosis, much lower in the artery and the lowest in the cephalic vein. A strong influence of the mesh on the results concerning the maximal and area-averaged WSS was shown. The relation between simulations of the pulsating and stationary flow under time-averaged flow conditions was presented.
Neufeld, Lynnette; García-Guerra, Armando; Sánchez-Francia, Domingo; Newton-Sánchez, Oscar; Ramírez-Villalobos, María Dolores; Rivera-Dommarco, Juan
2002-01-01
To assess the comparability of hemoglobin concentration (Hb) in venous and capillary blood measured by Hemocue and an automated spectrophotometer (Celldyn) and to document the influence of type of blood (capillary or venous) and analysis method on anemia prevalence estimates. Between February and May 2000, capillary and venous samples were collected from 72 adults and children at Hospital del Niño Morelense (Morelos State Children's Hospital) in Cuernavaca, Morelos, Mexico, and assessed for Hb using the Hemocue and Celldyn methods. Estimated Hb levels were compared using the concordance correlation coefficient and Student's t test for paired data. The sensitivity and specificity for anemia diagnosis were estimated and compared between type of blood and method of assessment. Capillary blood had higher Hb (+0.5 g/dl) than venous blood in adults and children, as did samples assessed by Celldyn compared to Hemocue (+0.3 g/dl). Specificity to detect anemia was adequate (> 0.90) but sensitivity was low for capillary blood assessed by Hemocue (< 0.80). The difference in Hb between venous and capillary blood is likely related to biological variability. Hemoglobin concentration in capillary blood assessed by Hemocue provides an adequate estimation of population anemia prevalence but may result in excess false negative diagnoses among individuals. The results of this study stress the importance of sample collection technique, particularly for children. Method of analysis and sampling site need to be taken into consideration in field studies. The English version of this paper is available too at: http://www.insp.mx/salud/index.html.
Gong, Ping; Luo, Song-Hui; Li, Xiao-Lin; Guo, Yuan-Lin; Zhu, Cheng-Gang; Xu, Rui-Xia; Li, Sha; Dong, Qian; Liu, Geng; Chen, Juan; Zeng, Rui-Xiang; Li, Jian-Jun
2014-12-01
Although the study on the relationship between ABO blood groups and coronary atherosclerosis has a long history, few data is available regarding ABO to severity of coronary atherosclerosis in a large cohort study. Therefore, the present study aimed to investigate the relation of the ABO blood groups to the severity of coronary atherosclerosis assessed by Gensini score (GS) in a large Chinese cohort undergoing coronary angiography. A total of 2919 consecutive patients undergoing coronary angiography were enrolled, and their baseline characteristics and ABO blood groups were collected. The GS was calculated as 1st tertile (0-10), 2nd tertile (11-36), 3rd tertile (>36) according to angiographic results. The relation of the ABO blood groups to GS was investigated. The frequency of blood group A was significantly higher in the upper GS tertiles (24.4% vs. 28.2% vs. 29.5%, p = 0.032). Multivariable linear regression analysis revealed that blood group A was independently associated with GS (β = 0.043, p = 0.017). Likewise, multivariable logistic regression analysis showed that group A remained significantly associated with mid-high GS (OR = 1.44, 95% CI 1.16-1.80, p = 0.001), and the group O was showed as a protective factor (OR = 0.77, 95% CI = 0.65-0.92, p = 0.004). In this large Chinese cohort study, the data indicated that there was an association between ABO blood groups and the severity of coronary atherosclerosis. Moreover, the blood group A was an independent risk factor for serious coronary atherosclerosis. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Automated analysis of blood pressure measurements (Korotkov sound)
NASA Technical Reports Server (NTRS)
Golden, D. P.; Hoffler, G. W.; Wolthuis, R. A.
1972-01-01
Automatic system for noninvasive measurements of arterial blood pressure is described. System uses Korotkov sound processor logic ratios to identify Korotkov sounds. Schematic diagram of system is provided to show components and method of operation.
27 CFR 1.60 - Use of distilled spirits.
Code of Federal Regulations, 2011 CFR
2011-04-01
... laboratory for use exclusively in scientific research; (3) For use at any hospital, blood bank, or sanitarium (including use in making analysis or test at such hospital, blood bank, or sanitarium), or at any...
Gene Expression Analysis in Human Breast Cancer Associated Blood Vessels
Jones, Dylan T.; Lechertier, Tanguy; Mitter, Richard; Herbert, John M. J.; Bicknell, Roy; Jones, J. Louise; Li, Ji-Liang; Buffa, Francesca; Harris, Adrian L.; Hodivala-Dilke, Kairbaan
2012-01-01
Angiogenesis is essential for solid tumour growth, whilst the molecular profiles of tumour blood vessels have been reported to be different between cancer types. Although presently available anti-angiogenic strategies are providing some promise for the treatment of some cancers it is perhaps not surprisingly that, none of the anti-angiogenic agents available work on all tumours. Thus, the discovery of novel anti-angiogenic targets, relevant to individual cancer types, is required. Using Affymetrix microarray analysis of laser-captured, CD31-positive blood vessels we have identified 63 genes that are upregulated significantly (5–72 fold) in angiogenic blood vessels associated with human invasive ductal carcinoma (IDC) of the breast as compared with blood vessels in normal human breast. We tested the angiogenic capacity of a subset of these genes. Genes were selected based on either their known cellular functions, their enriched expression in endothelial cells and/or their sensitivity to anti-VEGF treatment; all features implicating their involvement in angiogenesis. For example, RRM2, a ribonucleotide reductase involved in DNA synthesis, was upregulated 32-fold in IDC-associated blood vessels; ATF1, a nuclear activating transcription factor involved in cellular growth and survival was upregulated 23-fold in IDC-associated blood vessels and HEX-B, a hexosaminidase involved in the breakdown of GM2 gangliosides, was upregulated 8-fold in IDC-associated blood vessels. Furthermore, in silico analysis confirmed that AFT1 and HEX-B also were enriched in endothelial cells when compared with non-endothelial cells. None of these genes have been reported previously to be involved in neovascularisation. However, our data establish that siRNA depletion of Rrm2, Atf1 or Hex-B had significant anti-angiogenic effects in VEGF-stimulated ex vivo mouse aortic ring assays. Overall, our results provide proof-of-principle that our approach can identify a cohort of potentially novel anti-angiogenic targets that are likley to be, but not exclusivley, relevant to breast cancer. PMID:23056178
Laboratory Workflow Analysis of Culture of Periprosthetic Tissues in Blood Culture Bottles.
Peel, Trisha N; Sedarski, John A; Dylla, Brenda L; Shannon, Samantha K; Amirahmadi, Fazlollaah; Hughes, John G; Cheng, Allen C; Patel, Robin
2017-09-01
Culture of periprosthetic tissue specimens in blood culture bottles is more sensitive than conventional techniques, but the impact on laboratory workflow has yet to be addressed. Herein, we examined the impact of culture of periprosthetic tissues in blood culture bottles on laboratory workflow and cost. The workflow was process mapped, decision tree models were constructed using probabilities of positive and negative cultures drawn from our published study (T. N. Peel, B. L. Dylla, J. G. Hughes, D. T. Lynch, K. E. Greenwood-Quaintance, A. C. Cheng, J. N. Mandrekar, and R. Patel, mBio 7:e01776-15, 2016, https://doi.org/10.1128/mBio.01776-15), and the processing times and resource costs from the laboratory staff time viewpoint were used to compare periprosthetic tissues culture processes using conventional techniques with culture in blood culture bottles. Sensitivity analysis was performed using various rates of positive cultures. Annualized labor savings were estimated based on salary costs from the U.S. Labor Bureau for Laboratory staff. The model demonstrated a 60.1% reduction in mean total staff time with the adoption of tissue inoculation into blood culture bottles compared to conventional techniques (mean ± standard deviation, 30.7 ± 27.6 versus 77.0 ± 35.3 h per month, respectively; P < 0.001). The estimated annualized labor cost savings of culture using blood culture bottles was $10,876.83 (±$337.16). Sensitivity analysis was performed using various rates of culture positivity (5 to 50%). Culture in blood culture bottles was cost-effective, based on the estimated labor cost savings of $2,132.71 for each percent increase in test accuracy. In conclusion, culture of periprosthetic tissue in blood culture bottles is not only more accurate than but is also cost-saving compared to conventional culture methods. Copyright © 2017 American Society for Microbiology.
Gao, Fuqiang; Ma, Jinhui; Sun, Wei; Guo, Wanshou; Li, Zirong; Wang, Weiguo
2016-08-01
Efficacy and safety of topical application of a fibrin sealant (FS) compared with intravenous administration of tranexamic acid (TXA) for reducing blood loss after total knee arthroplasty (TKA) is controversial. We undertook a meta-analysis to compare the effects of topical application of FS or intravenous administration of TXA on blood loss after TKA. PubMed, Medline, Embase, Web of Science and the Cochrane Library were searched to identify studies comparing FS with TXA for TKA patients. The mean difference (MD) of blood loss, hemoglobin value, and odds ratios (ORs) of transfusion requirements and adverse events in FS and TXA groups were pooled throughout the study. Relevant data were analyzed using RevMan v5.3. Five studies involving 359 patients were included (181 FS vs. 178 TXA). TXA use had a significantly lower prevalence of blood transfusion (OR = 3.14; 95% confidence interval (CI), 1.67 to 5.90, P = 0.0004) and higher hemoglobin level (MD = -1.23; 95% CI, -2.19 to -0.27, P = 0.01) than FS in the early postoperative period. No significant difference was seen in total blood loss between the two groups (MD = 198.06; 95% CI, -267.45 to 663.57; P = 0.40). There were no significant differences in adverse events, superficial infections, or deep-vein thrombosis among study groups. Our meta-analysis suggests that intravenous administration of TXA for patients undergoing TKA may reduce blood-transfusion requirements and maintain higher hemoglobin levels compared with topical application of FS in the early postoperative period. There were no significant differences in total calculated blood loss and prevalence of complications between the two groups. However, owing to the variation of included studies, no firm conclusions can be drawn. Copyright © 2016 IJS Publishing Group Ltd. Published by Elsevier Ltd. All rights reserved.
Noninvasive methods for haemoglobin screening in prospective blood donors.
Belardinelli, A; Benni, M; Tazzari, P L; Pagliaro, P
2013-08-01
The haemoglobin level of prospective blood donors is usually performed on blood obtained by from the finger pulp by fingerstick with a lancet and filling a capillary tube with a sample. New noninvasive methods are now available for rapid, noninvasive predonation haemoglobin screening. Prospective blood donors at our blood centre were tested, in two different trials, as follows: by the NBM 200 (OrSense) test (n = 445 donors) and by the Pronto-7 (Masimo) test (n = 463 donors). The haemoglobin values of each trial and the haemoglobin of finger pulp blood obtained by fingerstick with a lancet (HemoCue) were compared with the haemoglobin values obtained from a venous sample on a Cell Counter (Beckman Coulter). Comparison of Beckman Coulter Cell Counter and OrSense and results showed a bias of 0.29 g/dl, the standard deviation of the differences (SDD) of 0.98 and 95% limits of agreement from -1.64 to 2.21, using Bland and Altman statistical methodology. Comparison of Masimo and Beckman Coulter Cell Counter results showed a bias of -0.53 g/dl, SDD of 1.04 and 95% limits of agreement from -2.57 to 1.51. Cumulative analysis of all 908 donors, as tested by the usual fingerstick test showed a bias of 0.83 g/dl, SDD of 0.70 and 95% limits of agreement from -0.54 to 2.20 compared with the Coulter Cell Counter. Compared with the Coulter Counter, the specificity of the methods was 99.5% for fingerstick, 97% for OrSense and 83% for Massimo, and the sensitivity was 99, 98 and 93%, respectively. Analysis of finger pulp blood by either direct sampling by fingerstick and Hemocue, or by noninvasive haemoglobin tests does not replicate the results of cell counter analysis of venous samples. Compared with fingerstick, noninvasive haemoglobin tests eliminate pain and reduce stress, but have a lower level of specificity and sensitivity. © 2013 International Society of Blood Transfusion.
Rosen, Lisa M.; Liu, Tao; Merchant, Roland C.
2016-01-01
BACKGROUND Blood and body fluid exposures are frequently evaluated in emergency departments (EDs). However, efficient and effective methods for estimating their incidence are not yet established. OBJECTIVE Evaluate the efficiency and accuracy of estimating statewide ED visits for blood or body fluid exposures using International Classification of Diseases, Ninth Revision (ICD-9), code searches. DESIGN Secondary analysis of a database of ED visits for blood or body fluid exposure. SETTING EDs of 11 civilian hospitals throughout Rhode Island from January 1, 1995, through June 30, 2001. PATIENTS Patients presenting to the ED for possible blood or body fluid exposure were included, as determined by prespecified ICD-9 codes. METHODS Positive predictive values (PPVs) were estimated to determine the ability of 10 ICD-9 codes to distinguish ED visits for blood or body fluid exposure from ED visits that were not for blood or body fluid exposure. Recursive partitioning was used to identify an optimal subset of ICD-9 codes for this purpose. Random-effects logistic regression modeling was used to examine variations in ICD-9 coding practices and styles across hospitals. Cluster analysis was used to assess whether the choice of ICD-9 codes was similar across hospitals. RESULTS The PPV for the original 10 ICD-9 codes was 74.4% (95% confidence interval [CI], 73.2%–75.7%), whereas the recursive partitioning analysis identified a subset of 5 ICD-9 codes with a PPV of 89.9% (95% CI, 88.9%–90.8%) and a misclassification rate of 10.1%. The ability, efficiency, and use of the ICD-9 codes to distinguish types of ED visits varied across hospitals. CONCLUSIONS Although an accurate subset of ICD-9 codes could be identified, variations across hospitals related to hospital coding style, efficiency, and accuracy greatly affected estimates of the number of ED visits for blood or body fluid exposure. PMID:22561713
Comparison of Blood Loss in Laser Lipolysis vs Traditional Liposuction.
Abdelaal, Mohammed Mahmoud; Aboelatta, Yasser Abdallah
2014-08-01
Laser-assisted liposuction has been associated with reduced blood loss. However, this clinical finding has not been evaluated objectively. In this study, the authors objectively estimated the blood loss volume associated with laser lipolysis vs traditional liposuction in various anatomic regions. In this prospective study, 56 patients underwent equal amounts of traditional and laser-assisted liposuction at 2 contralateral anatomic sites. Blood loss volumes were calculated from the lipoaspirates by measuring hemoglobin and red blood cell content. The data were analyzed statistically with repeated-measures analysis of variance and the Mann-Whitney U test. Laser lipolysis can reduce blood loss by more than 50% compared with traditional liposuction. Laser lipolysis resulted in significant reductions in mean blood loss volumes in the abdomen, flanks, back, and breast. The authors provide objective evidence that laser lipolysis significantly reduces blood loss compared with traditional liposuction. 3. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.
Blood meal analysis of tabanid fly after it biting the rare Sumatran rhinoceros.
Rovie-Ryan, Jeffrine Japning; Zainuddin, Zainal Zahari; Marni, Wahap; Ahmad, Abdul Hamid; Ambu, Laurentius N; Payne, Junaidi
2013-02-01
To demonstrate a noninvasive large mammalian genetic sampling method using blood meal obtained from a tabanid fly. Blood meal was recovered from the abdomen of an engorged tabanid fly (Haematopota sp.) which was captured immediately after biting a Sumatran rhino in captivity. The blood was applied on to a Whatman FTA(®) blood card. Subsequent laboratory work was conducted to extract, amplify and sequence the DNA from the sample. Validation was done by sampling the hair follicles and blood samples from the rhinoceros and subjecting it to the same laboratory process. BLAST search and constructed phylogenetic trees confirmed the blood meal samples were indeed from the rhino. This method could be used in the field application to noninvasively collect genetic samples. Collection of tabanids and other haematophagous arthropods (e.g. mosquitoes and ticks) and other blood-sucking parasites (e.g. leeches and worms) could also provide information on vector-borne diseases.
Westenbrink, W
1992-01-01
Police officers can now demand blood samples from suspected impaired drivers in Canada to determine their Blood Alcohol Concentration. The medical laboratory technologist has been given the authority to take blood samples for legal purposes, as well as the authorization to complete certificates used as evidence in court. The proper procedures for the taking of blood samples and the completion of certificates are described in detail. The Criminal Code offences dealing with drinking and driving, the means by which police officers can legally obtain blood samples, the Blood Alcohol Kit, and the provision of providing blood collection evidence in court are discussed to aid the technologists in understanding their role in this process. The Criminal Code definitions of a "qualified medical practitioner", a "qualified technician", and "approved containers" are also described.
NASA Astrophysics Data System (ADS)
Custer, Jonathan R.; Kariuki, Michael; Beerntsen, Brenda T.; Viator, John A.
2010-02-01
Malaria is a blood borne infection affecting hundreds of millions of people worldwide2. The parasites reproduce within the blood cells, eventually causing their death and lysis. This process releases the parasites into the blood, continuing the cycle of infection. Usually, malaria is diagnosed only after a patient presents symptoms, including high fever, nausea, and, in advanced cases, coma and death. While invading the bloodstream of a host, malaria parasites convert hemoglobin into an insoluble crystal, known as hemozoin. These crystals, approximately several hundred nanometers in size, are contained within red blood cells and white blood cells that ingest free hemozoin in the blood. Thus, infected red blood cells and white blood cells contain a unique optical absorber that can be detected in blood samples using static photoacoustic detection methods. We separated the white blood cells from malaria infected blood and tested it in a photoacoustic set up using a tunable laser system consisting of an optical parametric oscillator pumped by an Nd:YAG laser with pulse duration of 5 ns. Our threshold of detection was 10 infected white blood cells per microliter, which is more sensitive than current diagnosis methods using microscopic analysis of blood.
Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming
2013-01-01
Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099
Blood as a route of transmission of uterine pathogens from the gut to the uterus in cows.
Jeon, Soo Jin; Cunha, Federico; Vieira-Neto, Achilles; Bicalho, Rodrigo C; Lima, Svetlana; Bicalho, Marcela L; Galvão, Klibs N
2017-08-25
Metritis is an inflammatory disease of the uterus caused by bacterial infection, particularly Bacteroides, Porphyromonas, and Fusobacterium. Bacteria from the environment, feces, or vagina are believed to be the only sources of uterine contamination. Blood seeps into the uterus after calving; therefore, we hypothesized that blood could also be a seeding source of uterine bacteria. Herein, we compared bacterial communities from blood, feces, and uterine samples from the same cows at 0 and 2 days postpartum using deep sequencing and qPCR. The vaginal microbiome 7 days before calving was also compared. There was a unique structure of bacterial communities by sample type. Principal coordinate analysis revealed two distinct clusters for blood and feces, whereas vaginal and uterine bacterial communities were more scattered, indicating greater variability. Cluster analysis indicated that uterine bacterial communities were more similar to fecal bacterial communities than vaginal and blood bacterial communities. Nonetheless, there were core genera shared by all blood, feces, vaginal, and uterine samples. Major uterine pathogens such as Bacteroides, Porphyromonas, and Fusobacterium were part of the core genera in blood, feces, and vagina. Other uterine pathogens such as Prevotella and Helcococcus were not part of the core genera in vaginal samples. In addition, uterine pathogens showed a strong and significant interaction with each other in the network of blood microbiota, but not in feces or vagina. These microbial interactions in blood may be an important component of disease etiology. The copy number of total bacteria in blood and uterus was correlated; the same did not occur in other sites. Bacteroides heparinolyticus was more abundant in the uterus on day 0, and both B. heparinolyticus and Fusobacterium necrophorum were more abundant in the uterus than in the blood and feces on day 2. This indicates that B. heparinolyticus has a tropism for the uterus, whereas both pathogens thrive in the uterine environment early postpartum. Blood harbored a unique microbiome that contained the main uterine pathogens such as Bacteroides, Porphyromonas, and Fusobacterium. The presence of these pathogens in blood shortly after calving shows the feasibility of hematogenous spread of uterine pathogens in cows.
Moore, Carmel; Sambrook, Jennifer; Walker, Matthew; Tolkien, Zoe; Kaptoge, Stephen; Allen, David; Mehenny, Susan; Mant, Jonathan; Di Angelantonio, Emanuele; Thompson, Simon G; Ouwehand, Willem; Roberts, David J; Danesh, John
2014-09-17
Ageing populations may demand more blood transfusions, but the blood supply could be limited by difficulties in attracting and retaining a decreasing pool of younger donors. One approach to increase blood supply is to collect blood more frequently from existing donors. If more donations could be safely collected in this manner at marginal cost, then it would be of considerable benefit to blood services. National Health Service (NHS) Blood and Transplant in England currently allows men to donate up to every 12 weeks and women to donate up to every 16 weeks. In contrast, some other European countries allow donations as frequently as every 8 weeks for men and every 10 weeks for women. The primary aim of the INTERVAL trial is to determine whether donation intervals can be safely and acceptably decreased to optimise blood supply whilst maintaining the health of donors. INTERVAL is a randomised trial of whole blood donors enrolled from all 25 static centres of NHS Blood and Transplant. Recruitment of about 50,000 male and female donors started in June 2012 and was completed in June 2014. Men have been randomly assigned to standard 12-week versus 10-week versus 8-week inter-donation intervals, while women have been assigned to standard 16-week versus 14-week versus 12-week inter-donation intervals. Sex-specific comparisons will be made by intention-to-treat analysis of outcomes assessed after two years of intervention. The primary outcome is the number of blood donations made. A key secondary outcome is donor quality of life, assessed using the Short Form Health Survey. Additional secondary endpoints include the number of 'deferrals' due to low haemoglobin (and other factors), iron status, cognitive function, physical activity, and donor attitudes. A comprehensive health economic analysis will be undertaken. The INTERVAL trial should yield novel information about the effect of inter-donation intervals on blood supply, acceptability, and donors' physical and mental well-being. The study will generate scientific evidence to help formulate blood collection policies in England and elsewhere. Current Controlled Trials ISRCTN24760606, 25 January 2012.
Race and diurnal blood pressure patterns. A review and meta-analysis.
Profant, J; Dimsdale, J E
1999-05-01
Investigators have reported variable findings regarding the role of race in diurnal blood pressure patterns. We performed a review and meta-analysis of this literature to identify the overall effect of race on circadian blood pressure patterns. Eighteen studies involving 2852 participants were reviewed. Meta-analyses were conducted using effect sizes calculated from the data provided directly in the study reports. Separate meta-analyses were conducted on effect sizes for differences between blacks and whites in daytime and nighttime systolic and diastolic blood pressure and nocturnal dip in systolic and diastolic blood pressure. To evaluate discrepancies in findings from studies involving American versus non-American blacks, overall meta-analyses as well as within-subset meta-analyses of black/white differences were conducted for comparisons involving American and non-American blacks. Results of overall meta-analyses indicate that blacks experience higher levels of systolic and diastolic blood pressure, both at night and during the day. These differences were significantly greater at night than during the day (P<0.05). Results of within-subset analyses involving American blacks mirrored those for all black/white comparisons, except that the effect of race on nocturnal dip, ie, that American blacks experienced less of a dip in both systolic and diastolic blood pressure at night, was significant (P<0.05). In contrast, the effect of race on nocturnal dip was not significant for comparisons involving non-American blacks. These results suggest a consistent difference in the chronobiology of blood pressure, particularly in American blacks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Byung-Kook; Kim, Yangho, E-mail: yanghokm@nuri.net
Introduction: We present data from the Korean National Health and Nutrition Examination Survey 2008-2009 on the distribution of blood cadmium levels and their association with iron deficiency in a representative sample of the adult Korean population. Methods: Serum ferritin was categorized into three levels: low (serum ferritin <15.0 {mu}g/L), low normal (15.0-30.0 {mu}g/L for women and 15.0-50.0 for men), and normal ({>=}30.0 {mu}g/L for women and {>=}50.0 for men), and its association with blood cadmium level was assessed after adjustment for various demographic and lifestyle factors. Results: Geometric means of blood cadmium in the low serum ferritin group in women,more » men, and all participants were significantly higher than in the normal group. Additionally, multiple regression analysis after adjusting for various covariates showed that blood cadmium was significantly higher in the low-ferritin group in women, men, and all participants compared with the normal group. We also found an association between serum ferritin and blood cadmium among never-smoking participants. Discussion: We found, similar to other recent population-based studies, an association between iron deficiency and increased blood cadmium in men and women, independent of smoking status. The results of the present study show that iron deficiency is associated with increased levels of blood cadmium in the general population.« less
Endo, Hidenori; Niizuma, Kuniyasu; Endo, Toshiki; Funamoto, Kenichi; Ohta, Makoto; Tominaga, Teiji
2016-01-01
This was a proof-of-concept computational fluid dynamics (CFD) study designed to identify atherosclerotic changes in intracranial aneurysms. We selected 3 patients with multiple unruptured aneurysms including at least one with atherosclerotic changes and investigated whether an image-based CFD study could provide useful information for discriminating the atherosclerotic aneurysms. Patient-specific geometries were constructed from three-dimensional data obtained using rotational angiography. Transient simulations were conducted under patient-specific inlet flow rates measured by phase-contrast magnetic resonance velocimetry. In the postanalyses, we calculated time-averaged wall shear stress (WSS), oscillatory shear index, and relative residence time (RRT). The volume of blood flow entering aneurysms through the neck and the mean velocity of blood flow inside aneurysms were examined. We applied the age-of-fluid method to quantitatively assess the residence of blood inside aneurysms. Atherosclerotic changes coincided with regions exposed to disturbed blood flow, as indicated by low WSS and long RRT. Blood entered aneurysms in phase with inlet flow rates. The mean velocities of blood inside atherosclerotic aneurysms were lower than those inside nonatherosclerotic aneurysms. Blood in atherosclerotic aneurysms was older than that in nonatherosclerotic aneurysms, especially near the wall. This proof-of-concept study demonstrated that CFD analysis provided detailed information on the exchange and residence of blood that is useful for the diagnosis of atherosclerotic changes in intracranial aneurysms. PMID:27703491
Quality Improvement Methodologies Increase Autologous Blood Product Administration
Hodge, Ashley B.; Preston, Thomas J.; Fitch, Jill A.; Harrison, Sheilah K.; Hersey, Diane K.; Nicol, Kathleen K.; Naguib, Aymen N.; McConnell, Patrick I.; Galantowicz, Mark
2014-01-01
Abstract: Whole blood from the heart–lung (bypass) machine may be processed through a cell salvaging device (i.e., cell saver [CS]) and subsequently administered to the patient during cardiac surgery. It was determined at our institution that CS volume was being discarded. A multidisciplinary team consisting of anesthesiologists, perfusionists, intensive care physicians, quality improvement (QI) professionals, and bedside nurses met to determine the challenges surrounding autologous blood delivery in its entirety. A review of cardiac surgery patients’ charts (n = 21) was conducted for analysis of CS waste. After identification of practices that were leading to CS waste, interventions were designed and implemented. Fishbone diagram, key driver diagram, Plan–Do–Study–Act (PDSA) cycles, and data collection forms were used throughout this QI process to track and guide progress regarding CS waste. Of patients under 6 kg (n = 5), 80% had wasted CS blood before interventions, whereas those patients larger than 36 kg (n = 8) had 25% wasted CS before interventions. Seventy-five percent of patients under 6 kg who had wasted CS blood received packed red blood cell transfusions in the cardiothoracic intensive care unit within 24 hours of their operation. After data collection and didactic education sessions (PDSA Cycle I), CS blood volume waste was reduced to 5% in all patients. Identification and analysis of the root cause followed by implementation of education, training, and management of change (PDSA Cycle II) resulted in successful use of 100% of all CS blood volume. PMID:24783313
NASA Astrophysics Data System (ADS)
Zalesskaya, G. A.; Akulich, N. V.; Marochkov, A. V.; Laskina, O. V.; Mit'kovskaya, N. P.
2010-07-01
We have carried out a comprehensive analysis of the spectral characteristics of blood and blood components, gas-exchange and oximetry parameters for venous and arterial blood, central hemodynamic parameters, and the results of a complete blood count and chemistry panel before and after extracorporeal UV irradiation of the blood (UBI, ultraviolet blood irradiation) or intravenous exposure of blood to low-intensity emission from an He-Ne laser (LBI, laser blood irradiation). We have demonstrated the possibility of correcting the oxygentransport characteristics of blood by laser optical methods based on photodissociation of blood oxyhemoglobin. We have shown that the therapeutic effects initiated both by UBI and LBI are based on a single mechanism: a change in the balance between production of active oxygen species and their inhibition by antioxidants. The data obtained are of interest not only for studying the primary (molecular) mechanisms of action for photohemotherapy and their effect on processes occurring in the living body, but also can provide a basis for designing next-generation laser optical instruments and for development of not yet existing methods for assessing the therapeutic efficacy of photohemotherapy.
Microfluidic Blood Cell Preparation: Now and Beyond
Yu, Zeta Tak For; Yong, Koh Meng Aw; Fu, Jianping
2014-01-01
Blood plays an important role in homeostatic regulation with each of its cellular components having important therapeutic and diagnostic uses. Therefore, separation and sorting of blood cells has been of a great interest to clinicians and researchers. However, while conventional methods of processing blood have been successful in generating relatively pure fractions, they are time consuming, labor intensive, and are not optimal for processing small volume blood samples. In recent years, microfluidics has garnered great interest from clinicians and researchers as a powerful technology for separating blood into different cell fractions. As microfluidics involves fluid manipulation at the microscale level, it has the potential for achieving high-resolution separation and sorting of blood cells down to a single-cell level, with an added benefit of integrating physical and biological methods for blood cell separation and analysis on the same single chip platform. This paper will first review the conventional methods of processing and sorting blood cells, followed by a discussion on how microfluidics is emerging as an efficient tool to rapidly change the field of blood cell sorting for blood-based therapeutic and diagnostic applications. PMID:24515899
Jacewicz, R; Lewandowski, K; Rupa-Matysek, J; Jędrzejczyk, M; Berent, J
The study documents the risk that comes with DNA analysis of materials derived from patients after allogeneic hematopoietic stem cell transplantation (allo-HSCT) in forensic genetics. DNA chimerism was studied in 30 patients after allo-HSCT, based on techniques applied in contemporary forensic genetics, i.e. real-time PCR and multiplex PCR-STR with the use of autosomal DNA as well as Y-DNA markers. The results revealed that the DNA profile of the recipient's blood was identical with the donor's in the majority of cases. Therefore, blood analysis can lead to false conclusions in personal identification as well as kinship analysis. An investigation of buccal swabs revealed a mixture of DNA in the majority of recipients. Consequently, personal identification on the basis of stain analysis of the same origin may be impossible. The safest (but not ideal) material turned out to be the hair root. Its analysis based on autosomal DNA revealed 100% of the recipient's profile. However, an analysis based on Y-chromosome markers performed in female allo-HSCT recipients with male donors demonstrated the presence of donor DNA in hair cells - similarly to the blood and buccal swabs. In the light of potential risks arising from DNA profiling of biological materials derived from persons after allotransplantation in judicial aspects, certain procedures were proposed to eliminate such dangers. The basic procedures include abandoning the approach based exclusively on blood collection, both for kinship analysis and personal identification; asking persons who are to be tested about their history of allo-HSCT before sample collection and profile entry in the DNA database, and verification of DNA profiling based on hair follicles in uncertain cases.
Emerging microengineered tools for functional analysis and phenotyping of blood cells.
Li, Xiang; Chen, Weiqiang; Li, Zida; Li, Ling; Gu, Hongchen; Fu, Jianping
2014-11-01
The available techniques for assessing blood cell functions are limited considering the various types of blood cell and their diverse functions. In the past decade, rapid advances in microengineering have enabled an array of blood cell functional measurements that are difficult or impossible to achieve using conventional bulk platforms. Such miniaturized blood cell assay platforms also provide the attractive capabilities of reducing chemical consumption, cost, and assay time, as well as exciting opportunities for device integration, automation, and assay standardization. This review summarizes these contemporary microengineered tools and discusses their promising potential for constructing accurate in vitro models and rapid clinical diagnosis using minimal amounts of whole-blood samples. Copyright © 2014 Elsevier Ltd. All rights reserved.
Handheld Universal Diagnostic Sensor
NASA Technical Reports Server (NTRS)
Chan, Eugene
2012-01-01
The rHEALTH technology is designed to shrink an entire hospital testing laboratory onto a handheld device. A physician or healthcare provider performs the test by collecting a fingerstick of blood from a patient. The tiny volume of blood is inserted into the rHEALTH device. Inside the device is a microfluidic chip that contains small channels about the width of a human hair. These channels help move the blood and analyze the blood sample. The rHEALTH sensor uses proprietary reagents called nanostrips, which are nanoscale test strips that enable the clinical assays. The readout is performed by laser-induced fluorescence. Overall, the time from blood collection through analysis is less than a minute.
Two Fatal Intoxications Due to Tramadol Alone: Autopsy Case Reports and Review of the Literature.
Gioia, Sara; Lancia, Massimo; Bacci, Mauro; Suadoni, Fabio
2017-12-01
Since tramadol was marketed, it has been widely prescribed as a pain killer because of its relatively safe profile among opioids.Nevertheless, intoxication can occur: overdose can lead to fatal outcomes mostly in association with other drugs, via the potential interaction with serotonergic antidepressant medications, as well as the potential for increased central nervous system (CNS) depression.Fatal outcomes only attributable to tramadol are a rare entity. In this case report, 2 fatal cases are described due to tramadol stand-alone intoxication with peculiar characteristics.In case 1, gas chromatography - mass spectrometry analysis detected tramadol in all specimens (32 μg/mL in the heart blood, 23.9 μg/mL in the femoral blood, 3.3 μg/mL in the bile, and 1.4 μg/mL in the urine). No other CNS depressants were detected by toxicological analysis.In case 2, gas chromatography - mass spectrometry analysis detected tramadol in all specimens (7.5 μg/mL in the heart blood, 5.8 μg/mL in the femoral blood, and 18 μg/mL in the urine). No other CNS depressants were detected by toxicological analysis.Review of the literature was performed to clarify the actual knowledge on this topic.
USDA-ARS?s Scientific Manuscript database
Intensive lifestyle management or frequent goal-based monitoring with pharmacological management can be successful strategies for blood pressure control in overweight and obese adults with type 2 diabetes....
Blood-alcohol proficiency test program
DOT National Transportation Integrated Search
1975-01-01
A preliminary survey has been performed to ascertain the validity of the blood alcohol analysis performed by a number of laboratories on a voluntary basis. Values of accuracy and precision of the tests are presented. /Abstract from report summary pag...
Blood analysis by Raman spectroscopy.
Enejder, Annika M K; Koo, Tae-Woong; Oh, Jeankun; Hunter, Martin; Sasic, Slobodan; Feld, Michael S; Horowitz, Gary L
2002-11-15
Concentrations of multiple analytes were simultaneously measured in whole blood with clinical accuracy, without sample processing, using near-infrared Raman spectroscopy. Spectra were acquired with an instrument employing nonimaging optics, designed using Monte Carlo simulations of the influence of light-scattering-absorbing blood cells on the excitation and emission of Raman light in turbid medium. Raman spectra were collected from whole blood drawn from 31 individuals. Quantitative predictions of glucose, urea, total protein, albumin, triglycerides, hematocrit, and hemoglobin were made by means of partial least-squares (PLS) analysis with clinically relevant precision (r(2) values >0.93). The similarity of the features of the PLS calibration spectra to those of the respective analyte spectra illustrates that the predictions are based on molecular information carried by the Raman light. This demonstrates the feasibility of using Raman spectroscopy for quantitative measurements of biomolecular contents in highly light-scattering and absorbing media.
[Liquid biopsy analysis using cell-free DNA (cfDNA): Opportunities and limitations].
Dahl, E; Kloten, V
2015-11-01
Molecular biological analysis of nucleic acids in blood or other bodily fluids (i.e. liquid biopsy analyses) may supplement the pathologists' diagnostic armamentarium in a reasonable way-particularly in cancer precision medicine. Within the field of oncology, liquid biopsy can potentially be used to monitor tumor burden in the blood and to early detect emerging resistance in the course of targeted cancer therapies. An already approved application of liquid biopsy is the detection of epidermal growth factor receptor (EGFR) driver mutations in blood samples of lung cancer patients in those cases where no tissue biopsy is available. However, there is still currently considerable insecurity associated with blood-based DNA analytic methods that must be solved before liquid biopsy can be implemented for broader routine application in the diagnosis of cancer. In this article, the current state of development of liquid biopsy in molecular diagnostics from a pathology point of view is presented.
NASA Astrophysics Data System (ADS)
Jakovels, Dainis; Saknite, Inga; Spigulis, Janis
2014-05-01
Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new implementations as connection kits for mobile phones thus offering low cost screening devices. In this work we demonstrate simple implementation of LASCA imaging technique as connection kit for mobile phone for primary low-cost assessment of skin blood flow. Stabilized 650 nm and 532 nm laser diode modules were used for LASCA illumination. Dual wavelength illumination could provide additional information about skin hemoglobin and oxygenation level. The proposed approach was tested for arterial occlusion and heat test. Besides, blood flow maps of injured and provoked skin were demonstrated.
Engert, Larissa C; Weiler, Ulrike; Stefanski, Volker; Schmucker, Sonja S
2018-02-01
This data article is related to the original research article "Diurnal rhythms in peripheral blood immune cell numbers of domestic pigs" of Engert et al. [1] and describes diurnal rhythms in the number of CD8α - and CD8α + γδ T cells in peripheral blood of domestic pigs. Blood samples were taken from 18 animals over periods of up to 50 h and immune cell subtypes were determined by flow cytometry. Diurnal rhythmicity of cell numbers of γδ T cell subtypes was analyzed with cosinor analysis and different properties of rhythmicity (mesor, amplitude, and peak time) were calculated. In addition, associations between cell numbers of the investigated cell types in porcine blood with plasma cortisol concentration, hematocrit, and experimental conditions were identified with linear mixed model analysis.
Shang, Suhang; Li, Pei; Deng, Meiying; Jiang, Yu; Chen, Chen; Qu, Qiumin
2016-01-01
Hypertension is a modifiable risk factor for cognitive impairment, although the relationship between hypertension and cognitive impairment is not fully understood. The objective of this study was to investigate the effect of age on the relationship between blood pressure and cognitive impairment. Blood pressure and global cognitive function information was collected from 1799 participants (age 40-85) who lived in a village in the suburbs of Xi'an, China, during in-person interviews. Cognitive impairment was defined as a Mini-Mental State Examination (MMSE) score lower than the cutoff value. The effect of age on the relationship between blood pressure parameters [systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial blood pressure (MABP), and high blood pressure (HBP, SBP≥140 mm Hg and/or DBP≥90 mm Hg)] and cognitive impairment was analyzed by logistic regression models using interaction and stratified analysis. Blood pressure and age were regarded as both continuous and categorical data. A total of 231 participants were diagnosed as having cognitive impairment based on our criteria. Interaction analysis for the total population showed that SBP (when regarded as continuous data) was positively correlated with cognitive impairment (OR = 1.130 [95% CI, 1.028-1.242] per 10mmHg, P = 0.011); however, the age by SBP interaction term was negatively correlated with cognitive impairment (OR = 0.989 [95% CI, 0.982-0.997] per 10mmHg×year, P = 0.006), indicating that the relationship between SBP and cognitive impairment was age-dependent (OR = 1.130×0.989(age-55.5) per 10mmHg,40 ≤age≤85). When the blood pressure and age were considered as binary data, the results were similar to those obtained when they were considered as continuous variables. Stratified multivariate analysis revealed that the relationship between SBP (when regarded as continuous data) and cognitive impairment was positive for patients aged 40-49 years (OR = 1.349 [95% CI: 1.039-1.753] per 10mmHg, P = 0.025) and 50-59 years (OR = 1.185 [95% CI: 1.028-1.366] per 10mmHg, P = 0.019), whereas it tended to be negative for patients aged 60-69 years (OR = 0.878 [95% CI: 0.729-1.058] per 10mmHg, P = 0.171) and ≥70 years (OR = 0.927 [95% CI: 0.772-1.113] per 10mmHg, P = 0.416). Results similar to those for SBP were obtained for DBP, MABP and HBP as well. Subsequently, SBP, DBP and MABP were transformed into categorical data (SBP<140mmHg, 140mmHg≤SBP<160mmHg, and SBP≥160mmHg; DBP<90mmHg, 90mmHg≤DBP<100mmHg, and DBP≥100mmHg; MABP<100mmHg, 100mmHg≤MABP<110mmHg, and MABP≥110mmHg), and the stratified multivariate analysis was repeated. This analysis showed that the age-dependent association continued to exist and was especially prominent in the SBP≥160 mmHg, DBP≥90 mmHg and MABP≥110 mmHg groups. Elevated blood pressure is positively correlated with cognitive impairment in the middle-aged, but this positive association declines with increasing age. These results indicated that specific blood pressure management strategies for various age groups may be crucial for maintaining cognitive vitality.
Shang, Suhang; Li, Pei; Deng, Meiying; Jiang, Yu; Chen, Chen; Qu, Qiumin
2016-01-01
Background Hypertension is a modifiable risk factor for cognitive impairment, although the relationship between hypertension and cognitive impairment is not fully understood. The objective of this study was to investigate the effect of age on the relationship between blood pressure and cognitive impairment. Methods Blood pressure and global cognitive function information was collected from 1799 participants (age 40–85) who lived in a village in the suburbs of Xi'an, China, during in-person interviews. Cognitive impairment was defined as a Mini-Mental State Examination (MMSE) score lower than the cutoff value. The effect of age on the relationship between blood pressure parameters [systolic blood pressure (SBP), diastolic blood pressure (DBP), mean arterial blood pressure (MABP), and high blood pressure (HBP, SBP≥140 mm Hg and/or DBP≥90 mm Hg)] and cognitive impairment was analyzed by logistic regression models using interaction and stratified analysis. Blood pressure and age were regarded as both continuous and categorical data. Results A total of 231 participants were diagnosed as having cognitive impairment based on our criteria. Interaction analysis for the total population showed that SBP (when regarded as continuous data) was positively correlated with cognitive impairment (OR = 1.130 [95% CI, 1.028–1.242] per 10mmHg, P = 0.011); however, the age by SBP interaction term was negatively correlated with cognitive impairment (OR = 0.989 [95% CI, 0.982–0.997] per 10mmHg×year, P = 0.006), indicating that the relationship between SBP and cognitive impairment was age-dependent (OR = 1.130×0.989(age-55.5) per 10mmHg,40 ≤age≤85). When the blood pressure and age were considered as binary data, the results were similar to those obtained when they were considered as continuous variables. Stratified multivariate analysis revealed that the relationship between SBP (when regarded as continuous data) and cognitive impairment was positive for patients aged 40–49 years (OR = 1.349 [95% CI: 1.039–1.753] per 10mmHg, P = 0.025) and 50–59 years (OR = 1.185 [95% CI: 1.028–1.366] per 10mmHg, P = 0.019), whereas it tended to be negative for patients aged 60–69 years (OR = 0.878 [95% CI: 0.729–1.058] per 10mmHg, P = 0.171) and ≥70 years (OR = 0.927 [95% CI: 0.772–1.113] per 10mmHg, P = 0.416). Results similar to those for SBP were obtained for DBP, MABP and HBP as well. Subsequently, SBP, DBP and MABP were transformed into categorical data (SBP<140mmHg, 140mmHg≤SBP<160mmHg, and SBP≥160mmHg; DBP<90mmHg, 90mmHg≤DBP<100mmHg, and DBP≥100mmHg; MABP<100mmHg, 100mmHg≤MABP<110mmHg, and MABP≥110mmHg), and the stratified multivariate analysis was repeated. This analysis showed that the age-dependent association continued to exist and was especially prominent in the SBP≥160 mmHg, DBP≥90 mmHg and MABP≥110 mmHg groups. Conclusions Elevated blood pressure is positively correlated with cognitive impairment in the middle-aged, but this positive association declines with increasing age. These results indicated that specific blood pressure management strategies for various age groups may be crucial for maintaining cognitive vitality. PMID:27438476
2012-04-26
ISS030-E-257690 (26 April 2012) --- European Space Agency astronaut Andre Kuipers, Expedition 30 flight engineer, prepares for IMMUNE venous blood sample draws in the Columbus laboratory of the International Space Station. Following the blood draws, the samples were temporarily stowed in the Minus Eighty Laboratory Freezer for ISS 1 (MELFI-1) and later packed together with saliva samples on the Soyuz TMA-22 for return to Earth for analysis.
Repeated blood transfusions: Identification of a novel culprit of early graft failure in children.
Therrien, Judith; Guo, Kenneth; Guo, Liming; Liu, Aihua; Marelli, Ariane
2018-03-01
The attrition of right ventricle to pulmonary artery (RV-PA) grafts has been attributed in part to the body's immunologic response. We hypothesized that antibodies developed through blood transfusion, directed against the grafts, may result in accelerated degeneration and the need for re-intervention. This is a population-based study of the province of Quebec. We included children born between January 1, 1987 to December 31, 2006 who were diagnosed with a cono-truncal anomaly and had an RV-PA graft. The patients were followed for transfusion exposure and RV-PA graft re-intervention. Time to re-intervention in those exposed versus non-exposed was analyzed using Cox regression. Analysis was done in two time periods, before and after the calendar year 2000, given the change in blood preparation in the province of Quebec. There were 413 patients who met the inclusion criteria of a cono-truncal disorder. Of the whole study population, 69% received a blood transfusion. Cox regression analysis showed that among patients who had the initial graft performed (n=181) before year 2000, having 2 or more blood transfusion was associated with an nearly tripled risk of a re-intervention comparing to no blood transfusion (hazard ratio of 2.88; 95% confidence interval 1.05-7.91). In patients who had the initial graft performed after year 2000 (n=232), the associated risk increase was 7-fold (hazard ratio of 7.01; 95% confidence interval 3.06-16.02). Kaplan-Meier analyses confirmed the significant difference in the re-intervention free survival probabilities between those who received 2 or more blood product transfusion and those who did not as well: prior to year 2000 (67.9% vs. 88.0% at 5years, p=0.0201) as well as after year 2000 (39.7% vs. 82.8% at 5years, p<0.0001). In this population-based analysis, repeated blood product transfusion was associated with a significant increased risk of a need for RV-PA graft re-intervention. This data strongly suggest that repeated blood transfusion may adversely impact graft longevity. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Continuous intra-arterial blood-gas monitoring
NASA Astrophysics Data System (ADS)
Divers, George A.; Riccitelli, Samuel D.; Blais, Maurice; Hui, Henry K.
1993-05-01
Fiber optic technology and optical fluorescence have made the continuous monitoring of arterial blood gases a reality. Practical products that continuously monitor blood gases by use of an invasive sensor are now available. Anesthesiologists and intensive care physicians are beginning to explore the practical implications of this technology. With the advent of intra- arterial blood gas monitors it is possible to assess arterial blood gas values without the labor intensive steps of drawing blood and transporting a blood sample to the lab followed by the actual analysis. These intra-arterial blood gas monitors use new optical sensor technologies that can be reduced in size to the point that the sensor can be inserted into the arterial blood flow through a 20-gauge arterial cannula. In the best of these technologies the sensors accuracy and precision are similar to those in vitro analyzers. This presentation focuses on background technology and in vivo performance of a device developed, manufactured, and marketed by Puritan-Bennett Corporation.
Comparison of Four Saliva Detection Methods to Identify Expectorated Blood Spatter.
Park, Hee-Yeon; Son, Bu-Nam; Seo, Young-Il; Lim, Si-Keun
2015-11-01
Blood spatter analysis is an important step for crime scene reconstruction. The presence of saliva in blood spatter could indicate expectorated blood which is difficult to distinguish from impact spatter. In this study, four saliva test methods (SALIgAE(®) , Phadebas(®) sheet, RSID(™) -Saliva kit, and starch gel diffusion) were compared to identify the best method for detecting expectorated blood spatter. The RSID(™) -Saliva kit showed the highest sensitivity even when saliva was mixed with blood, and was not inhibited by the presence of blood. The SALIgAE(®) test provided easy and rapid results, but the yellow color of a positive reaction was overwhelmed by the red color of the blood. The starch gel diffusion method and the Phadebas(®) sheet exhibited relatively low sensitivity and the assay took a long time. When using the RSID(™) -Saliva kit for identifying saliva in blood, results should be read within 10 min. © 2015 American Academy of Forensic Sciences.
Harris, R D; Phillips, R L; Williams, P M; Kuzma, J W; Fraser, G E
1981-12-01
Distribution of systolic and diastolic blood pressures (measured with an automated blood pressure recorder) of two large groups of children-3,159 from Seventh-Day Adventist (SDA) schools and 4,681 from non-SDA schools-are reported. They boys and girls were from four different ethnic groups and attended grades one through 10 in 29 Southern California schools. The analysis of the data failed to show significant differences in mean blood pressure levels between the two groups of children at all ages, despite marked differences in life-style between the two groups, and despite the fact that adults from the two population groups have marked differences in mortality from diseases associated with elevated blood pressure. A comparison between boys and girls showed significantly higher trends in mean systolic blood pressure for boys after age 12. Inter-ethnic comparisons of blood pressure revealed that Black children of both sexes had slightly higher mean blood pressure levels at all ages.
Harris, R D; Phillips, R L; Williams, P M; Kuzma, J W; Fraser, G E
1981-01-01
Distribution of systolic and diastolic blood pressures (measured with an automated blood pressure recorder) of two large groups of children-3,159 from Seventh-Day Adventist (SDA) schools and 4,681 from non-SDA schools-are reported. They boys and girls were from four different ethnic groups and attended grades one through 10 in 29 Southern California schools. The analysis of the data failed to show significant differences in mean blood pressure levels between the two groups of children at all ages, despite marked differences in life-style between the two groups, and despite the fact that adults from the two population groups have marked differences in mortality from diseases associated with elevated blood pressure. A comparison between boys and girls showed significantly higher trends in mean systolic blood pressure for boys after age 12. Inter-ethnic comparisons of blood pressure revealed that Black children of both sexes had slightly higher mean blood pressure levels at all ages. PMID:7315999
NASA Astrophysics Data System (ADS)
Wróbel, M. S.; Gnyba, M.; Milewska, D.; Mitura, K.; Karpienko, K.
2015-09-01
A dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood samples, separated components: plasma, saline, washed erythrocytes in saline and human whole blood with biomarkers - biocompatible nanodiamonds (ND). Blood samples had been derived from a number of healthy donors. The results prove a correct setup arrangement, with adequate preprocessing of the data. The results of blood-ND mixtures measurements show no toxic effect on blood cells, which proves the NDs as a potential biocompatible biomarkers.
Arjunan, Maripandi; Al-Salamah, Ali A
2010-10-04
A six-year-old boy with high-grade fever and abdominal pain in the epigastric region was examined with ultrasonogram of the abdomen. Hematology-cell analysis, serology (Widal test), urine analysis, and blood cultures were also performed. The ultrasonogram was helpful for the identification of multiple organ involvement with Salmonella typhi. The results revealed mild hepatosplenomegaly, minimal ascitis, and mesenteric lympoadenopathy. Hematological analysis showed a white blood count of 6,300 cells mL-1; a red blood cell count of 4.54 million/cu mm. The erythrocyte sedimentation rate (ESR) was 24 mm/1 hr; hemoglobin level of 11.5 g/dl; and a platelet count of 206,000 cells/mL. The patient's serum was agglutinated with lipopolysaccharide (TO), the titre value was 1:320 dilution, and flagellar antigen (TH) titre was 1:640. The patient was diagnosed with typhoid fever. Ceftriaxone was given intravenously for five days and the patient fully recovered.
Jacques, Steven L
2015-04-01
This paper presents a practical approach for assessing the melanin and blood content of the skin from total diffuse reflectance spectra, R(λ), where λ is wavelength. A quick spectral analysis using just three wavelengths (585 nm, 700 nm and 800 nm) is presented, based on the 1985 work of Kollias and Baquer who documented epidermal melanin of skin using the slope of optical density (OD) between 620 nm and 720 nm. The paper describes the non-rectilinear character of such a quick analysis, and shows that almost any choice of two wavelengths in the 600-900 range can achieve the characterization of melanin. The extrapolation of the melanin slope to 585 nm serves as a baseline for subtraction from the OD (585 nm) to yield a blood perfusion score. Monte Carlo simulations created spectral data for a skin model with epidermis, papillary dermis and reticular dermis to illustrate the analysis. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Guerrini, G; Morabito, A; Samaja, M
2000-10-01
The aim is to determine if a single measurement of blood 2,3-diphosphoglycerate combined with gas analysis (pH, PCO2, PO2 and saturation) can identify the cause of an altered blood-oxygen affinity: the presence of an abnormal haemoglobin or a red cell disorder. The population (n=94) was divided into healthy controls (A, n=14), carriers of red cell disorders (B, n=72) and carriers of high oxygen affinity haemoglobins (C, n=8). Those variables were measured both in samples equilibrated at selected PCO2 and PO2 and in venous blood. In the univariable approach applied to equilibrated samples, we correctly identified C subjects in 93.6% or 96.8% of the cases depending on the selected variable, the standard P50 (PO2 at which 50% of haemoglobin is oxygenated) or a composite variable calculated from the above measurements. After introducing the haemoglobin concentration as a further discriminating variable, the A and B subjects were correctly identified in 91.9% or 94.2% of the cases, respectively. These figures become 93.0% or 86.1%, and 93.7% or 94.9% of the cases when using direct readings from venous blood, thereby avoiding the blood equilibration step. This test is feasible also in blood samples stored at 4 degrees C for 48 h, or at room temperature for 8 h.
Accurate label-free 3-part leukocyte recognition with single cell lens-free imaging flow cytometry.
Li, Yuqian; Cornelis, Bruno; Dusa, Alexandra; Vanmeerbeeck, Geert; Vercruysse, Dries; Sohn, Erik; Blaszkiewicz, Kamil; Prodanov, Dimiter; Schelkens, Peter; Lagae, Liesbet
2018-05-01
Three-part white blood cell differentials which are key to routine blood workups are typically performed in centralized laboratories on conventional hematology analyzers operated by highly trained staff. With the trend of developing miniaturized blood analysis tool for point-of-need in order to accelerate turnaround times and move routine blood testing away from centralized facilities on the rise, our group has developed a highly miniaturized holographic imaging system for generating lens-free images of white blood cells in suspension. Analysis and classification of its output data, constitutes the final crucial step ensuring appropriate accuracy of the system. In this work, we implement reference holographic images of single white blood cells in suspension, in order to establish an accurate ground truth to increase classification accuracy. We also automate the entire workflow for analyzing the output and demonstrate clear improvement in the accuracy of the 3-part classification. High-dimensional optical and morphological features are extracted from reconstructed digital holograms of single cells using the ground-truth images and advanced machine learning algorithms are investigated and implemented to obtain 99% classification accuracy. Representative features of the three white blood cell subtypes are selected and give comparable results, with a focus on rapid cell recognition and decreased computational cost. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Khairullina, Alphiya Y.; Oleinik, Tatiana V.
1995-01-01
Our previous works concerned with the development of methods for studying blood and action of low-intensity laser radiation on blood and erythrocyte suspensions had shown the light- scattering methods gave a large body of information on a medium studied due to the methodological relationship between irradiation processes and techniques for investigations. Detail analysis of spectral diffuse reflectivities and transmissivities of optically thick blood layers, spectral absorptivities calculated on this basis over 600 - 900 nm, by using different approximations, for a pathological state owing to hypoxia testifies to the optical significance of not only hemoglobin derivatives but also products of hemoglobin decomposition. Laser action on blood is specific and related to an initial state of blood absorption due to different composition of chromoproteids. This work gives the interpretation of spectral observations. Analysis of spectral dependencies of the exinction coefficient e, mean cosine m of phase function, and parameter Q equals (epsilon) (1-(mu) )H/(lambda) (H - hematocrit) testifies to decreasing the relative index of refraction of erythrocytes and to morphological changes during laser action under pathology owing to hypoxia. The possibility to obtain physical and chemical information on the state of blood under laser action in vivo is shown to be based on the method proposed by us for calculating multilayered structures modeling human organs and on the technical implementation of this method.
NASA Astrophysics Data System (ADS)
Riedl, M.; Suhrbier, A.; Malberg, H.; Penzel, T.; Bretthauer, G.; Kurths, J.; Wessel, N.
2008-07-01
The parameters of heart rate variability and blood pressure variability have proved to be useful analytical tools in cardiovascular physics and medicine. Model-based analysis of these variabilities additionally leads to new prognostic information about mechanisms behind regulations in the cardiovascular system. In this paper, we analyze the complex interaction between heart rate, systolic blood pressure, and respiration by nonparametric fitted nonlinear additive autoregressive models with external inputs. Therefore, we consider measurements of healthy persons and patients suffering from obstructive sleep apnea syndrome (OSAS), with and without hypertension. It is shown that the proposed nonlinear models are capable of describing short-term fluctuations in heart rate as well as systolic blood pressure significantly better than similar linear ones, which confirms the assumption of nonlinear controlled heart rate and blood pressure. Furthermore, the comparison of the nonlinear and linear approaches reveals that the heart rate and blood pressure variability in healthy subjects is caused by a higher level of noise as well as nonlinearity than in patients suffering from OSAS. The residue analysis points at a further source of heart rate and blood pressure variability in healthy subjects, in addition to heart rate, systolic blood pressure, and respiration. Comparison of the nonlinear models within and among the different groups of subjects suggests the ability to discriminate the cohorts that could lead to a stratification of hypertension risk in OSAS patients.
Correlation of salivary glucose level with blood glucose level in diabetes mellitus.
Gupta, Shreya; Nayak, Meghanand T; Sunitha, J D; Dawar, Geetanshu; Sinha, Nidhi; Rallan, Neelakshi Singh
2017-01-01
Saliva is a unique fluid, which is important for normal functioning of the oral cavity. Diabetes mellitus (DM) is a disease of absolute or relative insulin deficiency characterized by insufficient secretion of insulin by pancreatic beta-cells. The diagnosis of diabetes through blood is difficult in children, older adults, debilitated and chronically ill patients, so diagnosis by analysis of saliva can be potentially valuable as collection of saliva is noninvasive, easier and technically insensitive, unlike blood. The aim of the study was to correlate blood glucose level (BGL) and salivary glucose level (SGL) in DM patients. A cross-sectional study was conducted in 120 patients, who were categorized as 40 controlled diabetics, 40 uncontrolled diabetics and 40 healthy, age- and sex-matched individuals constituted the controls. The blood and unstimulated saliva samples were collected from the patients at the different intervals for fasting, random and postprandial levels. These samples were then subjected for analysis of glucose in blood and saliva using glucose oxidase/peroxidase reagent in HITACHI 902 (R) Automatic analyzer, and the results were recorded. The mean SGLs were higher in uncontrolled and controlled diabetic groups than in nondiabetic group. A highly statistically significant correlation was found between fasting saliva glucose and fasting blood glucose in all the groups. With increase in BGL, increase in SGL was observed in patients with diabetes suggesting that SGL can be used for monitoring glycemic level in DM.
ACCURACY OF NONINVASIVE ANESTHETIC MONITORING IN THE ANESTHETIZED GIRAFFE (GIRAFFA CAMELOPARDALIS).
Bertelsen, Mads F; Grøndahl, Carsten; Stegmann, George F; Sauer, Cathrine; Secher, Niels H; Hasenkam, J Michael; Damkjær, Mads; Aalkjær, Christian; Wang, Tobias
2017-09-01
This study evaluated the accuracy of pulse oximetry, capnography, and oscillometric blood pressure during general anesthesia in giraffes (Giraffa camelopardalis). Thirty-two giraffes anesthetized for physiologic experiments were instrumented with a pulse oximeter transmittance probe positioned on the tongue and a capnograph sampling line placed at the oral end of the endotracheal tube. A human size 10 blood pressure cuff was placed around the base of the tail, and an indwelling arterial catheter in the auricular artery continuously measured blood pressure. Giraffes were intermittently ventilated using a Hudson demand valve throughout the procedures. Arterial blood for blood gas analysis was collected at multiple time points. Relationships between oxygen saturation as determined by pulse oximetry and arterial oxygen saturation, between arterial carbon dioxide partial pressure and end-tidal carbon dioxide, and between oscillometric pressure and invasive arterial blood pressure were assessed, and the accuracy of pulse oximetry, capnography, and oscillometric blood pressure monitoring evaluated using Bland-Altman analysis. All three noninvasive methods provided relatively poor estimates of the reference values. Receiver operating characteristic curve fitting was used to determine cut-off values for hypoxia, hypocapnia, hypercapnia, and hypotension for dichotomous decision-making. Applying these cut-off values, there was reasonable sensitivity for detection of hypocapnia, hypercapnia, and hypotension, but not for hypoxemia. Noninvasive anesthetic monitoring should be interpreted with caution in giraffes and, ideally, invasive monitoring should be employed.
Brain-Derived Neurotrophic Factor Levels in Autism: A Systematic Review and Meta-Analysis.
Saghazadeh, Amene; Rezaei, Nima
2017-04-01
Brain-derived neurotrophic factor (BDNF) plays an important role in activity-dependent synaptic plasticity. Altered blood BDNF levels have been frequently identified in people with autism spectrum disorders (ASD). There are however wide discrepancies in the evidence. Therefore, we performed the present systematic review and meta-analysis aimed at qualitative and quantitative synthesis of studies that measured blood BDNF levels in ASD and control subjects. Observational studies were identified through electronic database searching and also hand-searching of reference lists of relevant articles. A total of 183 papers were initially identified for review and eventually twenty studies were included in the meta-analysis. A meta-analysis of blood BDNF in 887 patients with ASD and 901 control subjects demonstrated significantly higher BDNF levels in ASD compared to controls with the SMD of 0.47 (95% CI 0.07-0.86, p = 0.02). In addition subgroup meta-analyses were performed based on the BDNF specimen. The present meta-analysis study led to conclusion that BDNF might play role in autism initiation/ propagation and therefore it can be considered as a possible biomarker of ASD.
Davis, Rodeina; Geiger, Bradley; Gutierrez, Alfonso; Heaser, Julie; Veeramani, Dharmaraj
2009-07-01
Radio frequency identification (RFID) can be a key enabler for enhancing productivity and safety of the blood product supply chain. This article describes a systematic approach developed by the RFID Blood Consortium for a comprehensive feasibility and impact assessment of RFID application in blood centre operations. Our comprehensive assessment approach incorporates process-orientated and technological perspectives as well as impact analysis. Assessment of RFID-enabled process redesign is based on generic core processes derived from the three participating blood centres. The technological assessment includes RFID tag readability and performance evaluation, testing of temperature and biological effects of RF energy on blood products, and RFID system architecture design and standards. The scope of this article is limited to blood centre processes (from donation to manufacturing/distribution) for selected mainstream blood products (red blood cells and platelets). Radio frequency identification can help overcome a number of common challenges and process inefficiencies associated with identification and tracking of blood products. High frequency-based RFID technology performs adequately and safely for red blood cell and platelet products. Productivity and quality improvements in RFID-enabled blood centre processes can recoup investment cost in a 4-year payback period. Radio frequency identification application has significant process-orientated and technological implications. It is feasible and economically justifiable to incorporate RFID into blood centre processes.
Measurement of RBC agglutination with microscopic cell image analysis in a microchannel chip.
Cho, Chi Hyun; Kim, Ju Yeon; Nyeck, Agnes E; Lim, Chae Seung; Hur, Dae Sung; Chung, Chanil; Chang, Jun Keun; An, Seong Soo A; Shin, Sehyun
2014-01-01
Since Landsteiner's discovery of ABO blood groups, RBC agglutination has been one of the most important immunohematologic techniques for ABO and RhD blood groupings. The conventional RBC agglutination grading system for RhD blood typings relies on macroscopic reading, followed by the assignment of a grade ranging from (-) to (4+) to the degree of red blood cells clumping. However, with the new scoring method introduced in this report, microscopically captured cell images of agglutinated RBCs, placed in a microchannel chip, are used for analysis. Indeed, the cell images' pixel number first allows the differentiation of agglutinated and non-agglutinated red blood cells. Finally, the ratio of agglutinated RBCs per total RBC counts (CRAT) from 90 captured images is then calculated. During the trial, it was observed that the agglutinated group's CRAT was significantly higher (3.77-0.003) than that of the normal control (0). Based on these facts, it was established that the microchannel method was more suitable for the discrimination between agglutinated RBCs and non-agglutinated RhD negative, and thus more reliable for the grading of RBCs agglutination than the conventional method.
Raman Spectroscopy: A New Proposal for the Detection of Leukemia Using Blood Samples
NASA Astrophysics Data System (ADS)
Martínez-Espinosa, J. C.; González-Solís, J. L.; Frausto-Reyes, C.; Miranda-Beltrán, M. L.; Soria-Fregoso, C.; Medina-Valtierra, J.; Sánchez-Gómez, R.
2008-08-01
The use of Raman spectroscopy to analyze blood biochemistry and hence distinguish between normal and abnormal blood was investigated. The blood samples were obtained from 6 patients who were clinically diagnosed with leukemia and 6 healthy volunteer. The imprint was put under the microscope and several points were chosen for Raman measurement. All spectra were collected at confocal Raman micro-spectroscopy (Renishaw) with NIR 830 nm laser. It is shown that the serum samples from patients with leukemia and from the control group can be discriminated when the multivariate statistical methods of principal component analysis (PCA) and linear discriminated analysis (LDA) is applied to their Raman spectra. The ratios of some band intensities were analyzed and some band ratios were significant and corresponded to proteins, phospholipids, and polysaccharides. In addition, currently the degree of damage to the bone marrow is estimated through biopsies and therefore it is a very procedure painful. The preliminary results suggest that Raman spectroscopy could be a new technique to study the bone marrow using just blood samples.
Crowe, John B; Lanzarotta, Adam; Witkowski, Mark R; Andria, Sara E
2015-07-01
Suspect hypodermic needles and syringes were seized from an unlicensed individual who was allegedly injecting patients with silicone (polydimethylsiloxane [PDMS]) for cosmetic enhancement. Since control syringe barrels and needles often contain an interfering PDMS lubricant, a risk for false positives of foreign PDMS exists. The focus of this report was to minimize this risk and determine a quick and reliable test for the presence of blood in PDMS matrices. Using ATR-FT-IR spectroscopy, the risk for false-positive identification of foreign PDMS was reduced by (i) overfilling the sampling aperture to prevent spectral distortions and (ii) sampling a region of the suspect syringe/needle assembly where manufacturer-applied PDMS is not typically located. Analysis for blood indicated that the Teichman microchemical test was effective for detecting blood in the presence of PDMS. Overall, detecting PDMS established intent and detecting blood established that the needle containing the PDMS had been used for injection. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Development of class model based on blood biochemical parameters as a diagnostic tool of PSE meat.
Qu, Daofeng; Zhou, Xu; Yang, Feng; Tian, Shiyi; Zhang, Xiaojun; Ma, Lin; Han, Jianzhong
2017-06-01
A fast, sensitive and effective method based on the blood biochemical parameters for the detection of PSE meat was developed in this study. A total of 200 pigs were slaughtered in the same slaughterhouse. Meat quality was evaluated by measuring pH, electrical conductivity and color at 45min, 2h and 24h after slaughtering in M. longissimus thoracis et lumborum (LD). Blood biochemical parameters were determined in blood samples collected during carcass bleeding. Principal component analysis (PCA) biplot showed that high levels of exsanguination Creatine Kinase, Lactate Dehydrogenase, Aspertate aminotransferase, blood glucose and lactate were associated with the PSE meat, and the five biochemical parameters were found to be good indicators of PSE meat Discriminant function analysis (DFA) was able to clearly identify PSE meat using the five biochemical parameters as input data, and the class model is an effective diagnostic tool in pigs which can be used to detect the PSE meat and reduce economic loss for the company. Copyright © 2017 Elsevier Ltd. All rights reserved.
Blood meal analysis of culicoides (Diptera: ceratopogonidae) in central Tunisia.
Slama, Darine; Haouas, Najoua; Mezhoud, Habib; Babba, Hamouda; Chaker, Emna
2015-01-01
To evaluate the host preferences of Culicoides species (Diptera: Ceratopogonidae) in Central Tunisia, we identified the source of blood meals of field collected specimens by sequencing of the cytochrome b (cyt b) mitochondrial locus and Prepronociceptine single copy nuclear gene. The study includes the most common and abundant livestock associated species of biting midges in Tunisia: C. imicola, C. jumineri, C. newsteadi, C. paolae, C. cataneii, C. circumscriptus, C. kingi, C. pseudojumineri, C. submaritimus, C. langeroni, C. jumineri var and some unidentified C. species. Analysis of cyt b PCR products from 182 field collected blood-engorged females' midges revealed that 92% of them fed solely on mammalian species, 1.6% on birds, 2.4% on insects and 0.8% on reptiles. The blast results identified the blood origin of biting midges to the species level with exact or nearly exact matches (≥98%). The results confirm the presence of several Culicoides species, including proven vectors in Central Tunisia. Blood meal analyses show that these species will indeed feed on bigger mammals, thereby highlighting the risk that these viruses will be able to spread in Tunisia.
Blood Meal Analysis of Culicoides (Diptera: Ceratopogonidae) in Central Tunisia
Slama, Darine; Haouas, Najoua; Mezhoud, Habib; Babba, Hamouda; Chaker, Emna
2015-01-01
To evaluate the host preferences of Culicoides species (Diptera: Ceratopogonidae) in Central Tunisia, we identified the source of blood meals of field collected specimens by sequencing of the cytochrome b (cyt b) mitochondrial locus and Prepronociceptine single copy nuclear gene. The study includes the most common and abundant livestock associated species of biting midges in Tunisia: C. imicola, C. jumineri, C. newsteadi, C. paolae, C. cataneii, C. circumscriptus, C. kingi, C. pseudojumineri, C. submaritimus, C. langeroni, C. jumineri var and some unidentified C. species. Analysis of cyt b PCR products from 182 field collected blood-engorged females’ midges revealed that 92% of them fed solely on mammalian species, 1.6% on birds, 2.4% on insects and 0.8% on reptiles. The blast results identified the blood origin of biting midges to the species level with exact or nearly exact matches (≥98%). The results confirm the presence of several Culicoides species, including proven vectors in Central Tunisia. Blood meal analyses show that these species will indeed feed on bigger mammals, thereby highlighting the risk that these viruses will be able to spread in Tunisia. PMID:25793285
Wang, Zhao; Shen, Xiaofei
2017-10-01
This meta-analysis aimed to illustrate the efficacy and safety of combined topical and intravenous (IV) tranexamic acid (TXA) for blood loss control in primary total knee arthroplasty (TKA) patients. In April 2017, a systematic computer-based search was conducted in PubMed, EMBASE, Web of Science, Cochrane Database of Systematic Reviews, and Google database. Data on patients prepared for TKA surgery in studies that compared combined topical and IV TXA versus placebo, topical, or IV TXA alone were retrieved. The primary endpoint was the need for transfusion, total blood loss, hemoglobin drop, and the occurrence of deep venous thrombosis (DVT), pulmonary embolism (PE), and the infection. After testing for publication bias and heterogeneity between studies, data were aggregated for random-effects models when necessary. Seven clinical studies were ultimately included in the meta-analysis. Compared with IV TXA and control group, combined TXA was associated with less need for transfusion, blood loss, and hemoglobin drop (P < .05). There was no significant difference between the combined TXA and topical TXA in terms of the need for transfusion, total blood loss, and hemoglobin drop (P > .05). There was no significant difference between the complications (DVT, PE, and infection) between the combined TXA, IV TXA, topical TXA, and control group. Current meta-analysis suggests that the combined IV and topical TXA was superior than IV TXA or control group. There is still need for more studies to identify whether combined TXA was superior than topical TXA alone.
Cutajar, Marica; Thomas, David L; Hales, Patrick W; Banks, T; Clark, Christopher A; Gordon, Isky
2014-06-01
To investigate the reproducibility of arterial spin labelling (ASL) and dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI) and quantitatively compare these techniques for the measurement of renal blood flow (RBF). Sixteen healthy volunteers were examined on two different occasions. ASL was performed using a multi-TI FAIR labelling scheme with a segmented 3D-GRASE imaging module. DCE MRI was performed using a 3D-FLASH pulse sequence. A Bland-Altman analysis was used to assess repeatability of each technique, and determine the degree of correspondence between the two methods. The overall mean cortical renal blood flow (RBF) of the ASL group was 263 ± 41 ml min(-1) [100 ml tissue](-1), and using DCE MRI was 287 ± 70 ml min(-1) [100 ml tissue](-1). The group coefficient of variation (CVg) was 18 % for ASL and 28 % for DCE-MRI. Repeatability studies showed that ASL was more reproducible than DCE with CVgs of 16 % and 25 % for ASL and DCE respectively. Bland-Altman analysis comparing the two techniques showed a good agreement. The repeated measures analysis shows that the ASL technique has better reproducibility than DCE-MRI. Difference analysis shows no significant difference between the RBF values of the two techniques. Reliable non-invasive monitoring of renal blood flow is currently clinically unavailable. Renal arterial spin labelling MRI is robust and repeatable. Renal dynamic contrast-enhanced MRI is robust and repeatable. ASL blood flow values are similar to those obtained using DCE-MRI.
A comparison of the wavelet and short-time fourier transforms for Doppler spectral analysis.
Zhang, Yufeng; Guo, Zhenyu; Wang, Weilian; He, Side; Lee, Ting; Loew, Murray
2003-09-01
Doppler spectrum analysis provides a non-invasive means to measure blood flow velocity and to diagnose arterial occlusive disease. The time-frequency representation of the Doppler blood flow signal is normally computed by using the short-time Fourier transform (STFT). This transform requires stationarity of the signal during a finite time interval, and thus imposes some constraints on the representation estimate. In addition, the STFT has a fixed time-frequency window, making it inaccurate to analyze signals having relatively wide bandwidths that change rapidly with time. In the present study, wavelet transform (WT), having a flexible time-frequency window, was used to investigate its advantages and limitations for the analysis of the Doppler blood flow signal. Representations computed using the WT with a modified Morlet wavelet were investigated and compared with the theoretical representation and those computed using the STFT with a Gaussian window. The time and frequency resolutions of these two approaches were compared. Three indices, the normalized root-mean-squared errors of the minimum, the maximum and the mean frequency waveforms, were used to evaluate the performance of the WT. Results showed that the WT can not only be used as an alternative signal processing tool to the STFT for Doppler blood flow signals, but can also generate a time-frequency representation with better resolution than the STFT. In addition, the WT method can provide both satisfactory mean frequencies and maximum frequencies. This technique is expected to be useful for the analysis of Doppler blood flow signals to quantify arterial stenoses.
The blood perfusion and NADH/FAD content combined analysis in patients with diabetes foot
NASA Astrophysics Data System (ADS)
Dremin, Victor V.; Sidorov, Victor V.; Krupatkin, Alexander I.; Galstyan, Gagik R.; Novikova, Irina N.; Zherebtsova, Angelina I.; Zherebtsov, Evgeny A.; Dunaev, Andrey V.; Abdulvapova, Zera N.; Litvinova, Karina S.; Rafailov, Ilya E.; Sokolovski, Sergei G.; Rafailov, Edik U.
2016-03-01
Skin blood microcirculation and the metabolism activity of tissue were examined on the patients with type 2 diabetes. Laser Doppler flowmetry (LDF) with 1064 nm laser light source and fluorescence spectroscopy (FS) with excitation light of 365 nm and 450 nm have been used to monitor the blood perfusion and the content of coenzymes NADH and FAD. Concluding, the proposed combined LDF and tissue FS approach allows to identify the significant violations in the blood microcirculation and metabolic activity for type 2 diabetes patients.
NASA Astrophysics Data System (ADS)
Nikitaev, V. G.; Pronichev, A. N.; Polyakov, E. V.; Dmitrieva, V. V.; Tupitsyn, N. N.; Frenkel, M. A.; Mozhenkova, A. V.
2017-01-01
The work investigated the effect of the choice of color space component on blood cell detection based on the calculation of texture attributes of blood cells nuclei in bone marrow. The study identified the most informative color space and texture characteristics of blood cells, designed for components of these spaces. Significance ratio was introduced to assess the quality of features. We offered features that have enabled to divide lymphocytes from lymphoblasts. The selection of the features was based on the results of the data analysis.
Removal of Chronic Intravascular Blood Clots using Liquid Plasma
NASA Astrophysics Data System (ADS)
Jung, Jae-Chul; Choi, Myeong; Koo, Il; Yu, Zengqi; Collins, George
2011-10-01
An electrical embolectomy device for removing chronic intravascular blood clots using liquid plasma under saline environment was demonstrated. We employed a proxy experimental blood clot model of deep vein thrombosis (DVT) and actual equine blood clot. Thermal damage to contiguous tissue and the collagen denaturing via the plasma irradiation were investigated by histological analysis using birefringence of the tissue and verified by FT-IR spectroscopic study, respectively, which showed the high removal rate up to 2 mm per minute at room temperature and small thermal damage less than 200 μm.