Sample records for blood mimicking fluid

  1. Deriving a blood-mimicking fluid for particle image velocimetry in Sylgard-184 vascular models.

    PubMed

    Yousif, Majid Y; Holdsworth, David W; Poepping, Tamie L

    2009-01-01

    A new blood-mimicking fluid (BMF) has been developed for particle image velocimetry (PIV), which enables flow studies in vascular models (phantoms). A major difficulty in PIV that affects measurement accuracy is the refraction and distortion of light passing through the interface between the model and the fluid, due to the difference in refractive index (n) between the two materials. The problem can be eliminated by using a fluid with a refractive index matching that of the model. Such fluids are not commonly available, especially for vascular research where the fluid should also have a viscosity similar to human blood. In this work, a blood-mimicking fluid, composed of water (47.38% by weight), glycerol (36.94% by weight) and sodium iodide salt (15.68% by weight), was developed for compatibility with our silicone (Sylgard 184; n = 1.414) phantoms. The fluid exhibits a dynamic viscosity of 4.31+/-0.03 cP which lies within the range of human blood viscosity (4.4+/-0.6 cP). Both refractive index and viscosity were attained at 22.2+/-0.2 degrees C, which is a feasible room temperature, thus eliminating the need for a temperature-control system. The fluid will be used to study hemodynamics in vascular flow models fabricated from Sylgard 184.

  2. A blood-mimicking fluid for particle image velocimetry with silicone vascular models

    NASA Astrophysics Data System (ADS)

    Yousif, Majid Y.; Holdsworth, David W.; Poepping, Tamie L.

    2011-03-01

    For accurate particle image velocimetry measurements in hemodynamics studies, it is important to use a fluid with a refractive index ( n) matching that of the vascular models (phantoms) and ideally a dynamic viscosity matching human blood. In this work, a blood-mimicking fluid (BMF) composed of water, glycerol, and sodium iodide was formulated for a range of refractive indices to match most common silicone elastomers ( n = 1.40-1.43) and with corresponding dynamic viscosity within the average cited range of healthy human blood (4.4 ± 0.5 cP). Both refractive index and viscosity were attained at room temperature (22.2 ± 0.2°C), which eliminates the need for a temperature-control system. An optimally matched BMF, suitable for use in a vascular phantom ( n = 1.4140 ± 0.0008, Sylgard 184), was demonstrated with composition (by weight) of 47.38% water, 36.94% glycerol (44:56 glycerol-water ratio), and 15.68% sodium iodide salt, resulting in a dynamic viscosity of 4 .31 ± 0 .03 cP.

  3. Moderately nonlinear ultrasound propagation in blood-mimicking fluid.

    PubMed

    Kharin, Nikolay A; Vince, D Geoffrey

    2004-04-01

    In medical diagnostic ultrasound (US), higher than-in-water nonlinearity of body fluids and tissue usually does not produce strong nonlinearly distorted waves because of the high absorption. The relative influence of absorption and nonlinearity can be characterized by the Gol'dberg number Gamma. There are two limiting cases in nonlinear acoustics: weak waves (Gamma < 1) or strong waves (Gamma > 1). However, at diagnostic frequencies in tissue and body fluids, the nonlinear effects and effects of absorption more likely are comparable (Gol'dberg number Gamma approximately 1). The aim of this work was to study the nonlinear propagation of a moderately nonlinear US second harmonic signal in a blood-mimicking fluid. Quasilinear solutions to the KZK equation are presented, assuming radiation from a flat and geometrically focused circular Gaussian source. The solutions are expressed in a new simplified closed form and are in very good agreement with those of previous studies measuring and modeling Gaussian beams. The solutions also show good agreement with the measurements of the beams produced by commercially available transducers, even without special Gaussian shading.

  4. Mimicking multivalent protein-carbohydrate interactions for monitoring the glucosamine level in biological fluids and pharmaceutical tablets.

    PubMed

    Dey, Nilanjan; Bhattacharya, Santanu

    2017-05-11

    An easily synthesizable probe has been employed for dual mode sensing of glucosamine in pure water. The method was also applied for glucosamine estimation in blood serum samples and pharmaceutical tablets. Further, selective detection of glucosamine was also achieved using portable color strips.

  5. Simple bone cyst of mandible mimicking periapical cyst.

    PubMed

    Hs, Charan Babu; Rai, Bhagawan Das; Nair, Manju A; Astekar, Madhusudan S

    2012-05-29

    Simple bone cysts (SBC) are pseudocysts occurring less commonly in the maxillofacial region. The uncertain and unclear etiopathogenesis led to numerous synonyms to refer this particular cyst. These cysts are devoid of an epithelial lining and are usually empty or contain blood or straw-colored fluid. In jaws initially it mimics a periapical cyst and later can lead to cortical bone expansion warranting for radical approach, which is seldom required. SBC is predominantly diagnosed in first two decades of life. Here we report a case of solitary bone cyst mimicking a periapical cyst of a mandibular molar in a 37-year-old patient.

  6. Multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties

    PubMed Central

    Chen, Alvin I.; Balter, Max L.; Chen, Melanie I.; Gross, Daniel; Alam, Sheikh K.; Maguire, Timothy J.; Yarmush, Martin L.

    2016-01-01

    Purpose: This paper describes the design, fabrication, and characterization of multilayered tissue mimicking skin and vessel phantoms with tunable mechanical, optical, and acoustic properties. The phantoms comprise epidermis, dermis, and hypodermis skin layers, blood vessels, and blood mimicking fluid. Each tissue component may be individually tailored to a range of physiological and demographic conditions. Methods: The skin layers were constructed from varying concentrations of gelatin and agar. Synthetic melanin, India ink, absorbing dyes, and Intralipid were added to provide optical absorption and scattering in the skin layers. Bovine serum albumin was used to increase acoustic attenuation, and 40 μm diameter silica microspheres were used to induce acoustic backscatter. Phantom vessels consisting of thin-walled polydimethylsiloxane tubing were embedded at depths of 2–6 mm beneath the skin, and blood mimicking fluid was passed through the vessels. The phantoms were characterized through uniaxial compression and tension experiments, rheological frequency sweep studies, diffuse reflectance spectroscopy, and ultrasonic pulse-echo measurements. Results were then compared to in vivo and ex vivo literature data. Results: The elastic and dynamic shear behavior of the phantom skin layers and vessel wall closely approximated the behavior of porcine skin tissues and human vessels. Similarly, the optical properties of the phantom tissue components in the wavelength range of 400–1100 nm, as well as the acoustic properties in the frequency range of 2–9 MHz, were comparable to human tissue data. Normalized root mean square percent errors between the phantom results and the literature reference values ranged from 1.06% to 9.82%, which for many measurements were less than the sample variability. Finally, the mechanical and imaging characteristics of the phantoms were found to remain stable after 30 days of storage at 21 °C. Conclusions: The phantoms described in this work simulate the mechanical, optical, and acoustic properties of human skin tissues, vessel tissue, and blood. In this way, the phantoms are uniquely suited to serve as test models for multimodal imaging techniques and image-guided interventions. PMID:27277058

  7. Prevalence of driving with blood drug concentrations above proposed new legal limits in Norway: estimations based on drug concentrations in oral fluid.

    PubMed

    Gjerde, Hallvard; Normann, Per T; Christophersen, Asbjørg S; Mørland, Jørg

    2011-07-15

    To estimate the prevalence of driving with blood drug concentrations above the recently proposed Norwegian legal limits for drugged driving in random traffic. The results from a roadside survey of 10,816 drivers was used as basis for the estimation, and the most prevalent drugs were included. Three approaches were used to estimate the prevalence of drug concentrations above the proposed legal limits in blood based on drug concentrations in oral fluid: comparison with drug concentrations observed in oral fluid and blood in pharmacokinetic studies, estimating the prevalence of drug concentrations in blood by calculating the prevalence of drug concentrations in oral fluid that were larger than the limit in blood multiplied with mean oral fluid/blood ratios, and a mathematical simulation mimicking the relationship between drug concentration distributions in blood and oral fluid for populations of drug users. In total, alcohol or drugs were detected in 5.7% of the samples of oral fluid from drivers in normal traffic; 3.8% (n=410) were positive for the drugs that we included in the assessment. The estimation of drug concentrations in blood suggested that about 1.5% had concentrations above the proposed legal limits in blood for the studied drugs, which is about 40% of those who were positive for the drugs in oral fluid. The estimated prevalence of driving with concentrations of psychoactive drugs in blood above the proposed legal limits was for illegal drugs 0.4% and for medicinal drugs 1.1%. These may be regarded as minimum estimates as some drugs were not included in the assessment. These prevalences are higher than the prevalence of driving with blood alcohol concentrations above the legal limit of 0.2g/kg in Norway. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  8. Gadolinium-Based Contrast Agent Extravasation Mimicking Subarachnoid Hemorrhage After Electroconvulsive Therapy.

    PubMed

    Taydas, Onur; Ogul, Hayri; Ozcan, Halil; Kantarci, Mecit

    2018-06-01

    Electroconvulsive therapy (ECT) is a safe method that has been applied for many years in medical treatment-resistant depression treatment. In this case report, contrast extravasation due to deterioration of the blood-brain barrier after ECT mimicking subarachnoid hemorrhage (SAH) on magnetic resonance imaging (MRI) is discussed. A 70-year-old male patient who underwent ECT presented with sulcal hyperintensities suggesting subarachnoid hemorrhage on fluid-attenuated inversion recovery sequence of MRI obtained after ECT. However, there was no evidence to suggest SAH on nonenhanced brain computed tomography. It should be kept in mind that patients may have contrast extravasation due to deterioration of the blood-brain barrier after ECT, and other alternative methods should be used for the diagnosis of SAH in these patients, not MRI. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Simple bone cyst of mandible mimicking periapical cyst

    PubMed Central

    HS, Charan Babu; Rai, Bhagawan Das; Nair, Manju A.; Astekar, Madhusudan S.

    2012-01-01

    Simple bone cysts (SBC) are pseudocysts occurring less commonly in the maxillofacial region. The uncertain and unclear etiopathogenesis led to numerous synonyms to refer this particular cyst. These cysts are devoid of an epithelial lining and are usually empty or contain blood or straw-colored fluid. In jaws initially it mimics a periapical cyst and later can lead to cortical bone expansion warranting for radical approach, which is seldom required. SBC is predominantly diagnosed in first two decades of life. Here we report a case of solitary bone cyst mimicking a periapical cyst of a mandibular molar in a 37-year-old patient. PMID:24765458

  10. Extensional flow of blood analog solutions in microfluidic devices

    PubMed Central

    Sousa, P. C.; Pinho, F. T.; Oliveira, M. S. N.; Alves, M. A.

    2011-01-01

    In this study, we show the importance of extensional rheology, in addition to the shear rheology, in the choice of blood analog solutions intended to be used in vitro for mimicking the microcirculatory system. For this purpose, we compare the flow of a Newtonian fluid and two well-established viscoelastic blood analog polymer solutions through microfluidic channels containing both hyperbolic and abrupt contractions∕expansions. The hyperbolic shape was selected in order to impose a nearly constant strain rate at the centerline of the microchannels and achieve a quasihomogeneous and strong extensional flow often found in features of the human microcirculatory system such as stenoses. The two blood analog fluids used are aqueous solutions of a polyacrylamide (125 ppm w∕w) and of a xanthan gum (500 ppm w∕w), which were characterized rheologically in steady-shear flow using a rotational rheometer and in extension using a capillary breakup extensional rheometer (CaBER). Both blood analogs exhibit a shear-thinning behavior similar to that of whole human blood, but their relaxation times, obtained from CaBER experiments, are substantially different (by one order of magnitude). Visualizations of the flow patterns using streak photography, measurements of the velocity field using microparticle image velocimetry, and pressure-drop measurements were carried out experimentally for a wide range of flow rates. The experimental results were also compared with the numerical simulations of the flow of a Newtonian fluid and a generalized Newtonian fluid with shear-thinning behavior. Our results show that the flow patterns of the two blood analog solutions are considerably different, despite their similar shear rheology. Furthermore, we demonstrate that the elastic properties of the fluid have a major impact on the flow characteristics, with the polyacrylamide solution exhibiting a much stronger elastic character. As such, these properties must be taken into account in the choice or development of analog fluids that are adequate to replicate blood behavior at the microscale. PMID:21483662

  11. Design of a pulsatile flow facility to evaluate thrombogenic potential of implantable cardiac devices.

    PubMed

    Arjunon, Sivakkumar; Ardana, Pablo Hidalgo; Saikrishnan, Neelakantan; Madhani, Shalv; Foster, Brent; Glezer, Ari; Yoganathan, Ajit P

    2015-04-01

    Due to expensive nature of clinical trials, implantable cardiac devices should first be extensively characterized in vitro. Prosthetic heart valves (PHVs), an important class of these devices, have been shown to be associated with thromboembolic complications. Although various in vitro systems have been designed to quantify blood-cell damage and platelet activation caused by nonphysiological hemodynamic shear stresses in these PHVs, very few systems attempt to characterize both blood damage and fluid dynamics aspects of PHVs in the same test system. Various numerical modeling methodologies are also evolving to simulate the structural mechanics, fluid mechanics, and blood damage aspects of these devices. This article presents a completely hemocompatible small-volume test-platform that can be used for thrombogenicity studies and experimental fluid mechanics characterization. Using a programmable piston pump to drive freshly drawn human blood inside a cylindrical column, the presented system can simulate various physiological and pathophysiological conditions in testing PHVs. The system includes a modular device-mounting chamber, and in this presented case, a 23 mm St. Jude Medical (SJM) Regents® mechanical heart valve (MHV) in aortic position was used as the test device. The system was validated for its capability to quantify blood damage by measuring blood damage induced by the tester itself (using freshly drawn whole human blood). Blood damage levels were ascertained through clinically relevant assays on human blood while fluid dynamics were characterized using time-resolved particle image velocimetry (PIV) using a blood-mimicking fluid. Blood damage induced by the tester itself, assessed through Thrombin-anti-Thrombin (TAT), Prothrombin factor 1.2 (PF1.2), and hemolysis (Drabkins assay), was within clinically accepted levels. The hydrodynamic performance of the tester showed consistent, repeatable physiological pressure and flow conditions. In addition, the system contains proximity sensors to accurately capture leaflet motion during the entire cardiac cycle. The PIV results showed skewing of the leakage jet, caused by the asymmetric closing of the two leaflets. All these results are critical to characterizing the blood damage and fluid dynamics characteristics of the SJM Regents® MHV, proving the utility of this tester as a precise system for assessing the hemodynamics and thrombogenicity for various PHVs.

  12. Modeling and Measurement of Correlation between Blood and Interstitial Glucose Changes

    PubMed Central

    Shi, Ting; Li, Dachao; Li, Guoqing; Zhang, Yiming; Xu, Kexin; Lu, Luo

    2016-01-01

    One of the most effective methods for continuous blood glucose monitoring is to continuously measure glucose in the interstitial fluid (ISF). However, multiple physiological factors can modulate glucose concentrations and affect the lag phase between blood and ISF glucose changes. This study aims to develop a compensatory tool for measuring the delay in ISF glucose variations in reference to blood glucose changes. A theoretical model was developed based on biophysics and physiology of glucose transport in the microcirculation system. Blood and interstitial fluid glucose changes were measured in mice and rats by fluorescent and isotope methods, respectively. Computer simulation mimicked curves were fitted with data resulting from fluorescent measurements of mice and isotope measurements of rats, indicating that there were lag times for ISF glucose changes. It also showed that there was a required diffusion distance for glucose to travel from center of capillaries to interstitial space in both mouse and rat models. We conclude that it is feasible with the developed model to continuously monitor dynamic changes of blood glucose concentration through measuring glucose changes in ISF with high accuracy, which requires correct parameters for determining and compensating for the delay time of glucose changes in ISF. PMID:27239479

  13. Hydroxyapatite formation on titania-based materials in a solution mimicking body fluid: Effects of manganese and iron addition in anatase.

    PubMed

    Shin, Euisup; Kim, Ill Yong; Cho, Sung Baek; Ohtsuki, Chikara

    2015-03-01

    Hydroxyapatite formation on the surfaces of implanted materials plays an important role in osteoconduction of bone substitutes in bone tissues. Titania hydrogels are known to instigate hydroxyapatite formation in a solution mimicking human blood plasma. To date, the relationship between the surface characteristics of titania and hydroxyapatite formation on its surface remains unclear. In this study, titania powders with varying surface characteristics were prepared by addition of manganese or iron to examine hydroxyapatite formation in a type of simulated body fluid (Kokubo solution). Hydroxyapatite formation was monitored by observation of deposited particles with scale-like morphology on the prepared titania powders. The effect of the titania surface characteristics, i.e., crystal structure, zeta potential, hydroxy group content, and specific surface area, on hydroxyapatite formation was examined. Hydroxyapatite formation was observed on the surface of titania powders that were primarily anatase, and featured a negative zeta potential and low specific surface areas irrespective of the hydroxy group content. High specific surface areas inhibited the formation of hydroxyapatite because calcium and phosphate ions were mostly consumed by adsorption on the titania surface. Thus, these surface characteristics of titania determine its osteoconductivity following exposure to body fluid. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Nonsmoker Exposure to Secondhand Cannabis Smoke. III. Oral Fluid and Blood Drug Concentrations and Corresponding Subjective Effects

    PubMed Central

    Cone, Edward J.; Bigelow, George E.; Herrmann, Evan S.; Mitchell, John M.; LoDico, Charles; Flegel, Ronald; Vandrey, Ryan

    2015-01-01

    The increasing use of highly potent strains of cannabis prompted this new evaluation of human toxicology and subjective effects following passive exposure to cannabis smoke. The study was designed to produce extreme cannabis smoke exposure conditions tolerable to drug-free nonsmokers. Six experienced cannabis users smoked cannabis cigarettes [5.3% Δ9-tetrahydrocannabinol (THC) in Session 1 and 11.3% THC in Sessions 2 and 3] in a closed chamber. Six nonsmokers were seated alternately with smokers during exposure sessions of 1 h duration. Sessions 1 and 2 were conducted with no ventilation and ventilation was employed in Session 3. Oral fluid, whole blood and subjective effect measures were obtained before and at multiple time points after each session. Oral fluid was analyzed by ELISA (4 ng/mL cutoff concentration) and by LC–MS-MS (limit of quantitation) for THC (1 ng/mL) and total THCCOOH (0.02 ng/mL). Blood was analyzed by LC–MS-MS (0.5 ng/mL) for THC, 11-OH-THC and free THCCOOH. Positive tests for THC in oral fluid and blood were obtained for nonsmokers up to 3 h following exposure. Ratings of subjective effects correlated with the degree of exposure. Subjective effect measures and amounts of THC absorbed by nonsmokers (relative to smokers) indicated that extreme secondhand cannabis smoke exposure mimicked, though to a lesser extent, active cannabis smoking. PMID:26139312

  15. Feasibility of endoscopic laser speckle imaging modality in the evaluation of auditory disorder: study in bone-tissue phantom

    NASA Astrophysics Data System (ADS)

    Yu, Sungkon; Jang, Seulki; Lee, Sangyeob; Park, Jihoon; Ha, Myungjin; Radfar, Edalat; Jung, Byungjo

    2016-03-01

    This study investigates the feasibility of an endoscopic laser speckle imaging modality (ELSIM) in the measurement of perfusion of flowing fluid in optical bone tissue phantom(OBTP). Many studies suggested that the change of cochlear blood flow was correlated with auditory disorder. Cochlear microcirculation occurs under the 200μm thickness bone which is the part of the internal structure of the temporal bone. Concern has been raised regarding of getting correct optical signal from hard tissue. In order to determine the possibility of the measurement of cochlear blood flow under bone tissue using the ELSIM, optical tissue phantom (OTP) mimicking optical properties of temporal bone was applied.

  16. Nonsmoker Exposure to Secondhand Cannabis Smoke. III. Oral Fluid and Blood Drug Concentrations and Corresponding Subjective Effects.

    PubMed

    Cone, Edward J; Bigelow, George E; Herrmann, Evan S; Mitchell, John M; LoDico, Charles; Flegel, Ronald; Vandrey, Ryan

    2015-09-01

    The increasing use of highly potent strains of cannabis prompted this new evaluation of human toxicology and subjective effects following passive exposure to cannabis smoke. The study was designed to produce extreme cannabis smoke exposure conditions tolerable to drug-free nonsmokers. Six experienced cannabis users smoked cannabis cigarettes [5.3% Δ(9)-tetrahydrocannabinol (THC) in Session 1 and 11.3% THC in Sessions 2 and 3] in a closed chamber. Six nonsmokers were seated alternately with smokers during exposure sessions of 1 h duration. Sessions 1 and 2 were conducted with no ventilation and ventilation was employed in Session 3. Oral fluid, whole blood and subjective effect measures were obtained before and at multiple time points after each session. Oral fluid was analyzed by ELISA (4 ng/mL cutoff concentration) and by LC-MS-MS (limit of quantitation) for THC (1 ng/mL) and total THCCOOH (0.02 ng/mL). Blood was analyzed by LC-MS-MS (0.5 ng/mL) for THC, 11-OH-THC and free THCCOOH. Positive tests for THC in oral fluid and blood were obtained for nonsmokers up to 3 h following exposure. Ratings of subjective effects correlated with the degree of exposure. Subjective effect measures and amounts of THC absorbed by nonsmokers (relative to smokers) indicated that extreme secondhand cannabis smoke exposure mimicked, though to a lesser extent, active cannabis smoking. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. A Synthetic Fibrin-Crosslinking Polymer for Modulating Clot Properties and Inducing Hemostasis

    PubMed Central

    Chan, Leslie W.-G.; Wang, Xu; Wei, Hua; Pozzo, Lilo D.; White, Nathan J.; Pun, Suzie H.

    2015-01-01

    Clotting factor replacement is the standard management of acute bleeding in congenital and acquired bleeding disorders. We present a synthetic approach to hemostasis using an engineered hemostatic polymer (PolySTAT) that circulates innocuously in the blood, identifies sites of vascular injury, and promotes clot formation to stop bleeding. PolySTAT induces hemostasis by crosslinking the fibrin matrix within clots, mimicking the function of the transglutaminase Factor XIII. Furthermore, synthetic PolySTAT binds specifically to fibrin monomers and is uniformly integrated into fibrin fibers during fibrin polymerization, resulting in a fortified, hybrid polymer network with enhanced resistance to enzymatic degradation. In vivo hemostatic activity was confirmed in a rat model of trauma and fluid resuscitation in which intravenous administration of PolySTAT improved survival by reducing blood loss and resuscitation fluid requirements. PolySTAT-induced fibrin crosslinking is a novel approach to hemostasis utilizing synthetic polymers for non-invasive modulation of clot architecture with potentially wide-ranging therapeutic applications. PMID:25739763

  18. Environmental Stability and Infectivity of Hepatitis C Virus (HCV) in Different Human Body Fluids.

    PubMed

    Pfaender, Stephanie; Helfritz, Fabian A; Siddharta, Anindya; Todt, Daniel; Behrendt, Patrick; Heyden, Julia; Riebesehl, Nina; Willmann, Wiebke; Steinmann, Joerg; Münch, Jan; Ciesek, Sandra; Steinmann, Eike

    2018-01-01

    Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids. Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario. Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test. Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.

  19. Creutzfeldt-Jakob Disease Mimicking Alzheimer Disease and Dementia With Lewy Bodies-Findings of FDG PET With 3-Dimensional Stereotactic Surface Projection.

    PubMed

    Miyazawa, Nobuhiko

    2017-05-01

    A 78-year-old man received a diagnosis of sporadic Creutzfeldt-Jakob disease based on symptoms and findings of MRI, FDG PET, and cerebrospinal fluid markers. PET with 3-dimensional stereotactic surface projection (3D-SSP) showed that the distribution of hypometabolism mimicked that of Alzheimer disease. A 68-year-old woman was treated under a diagnosis of convulsion. Findings of MRI, PET, familial history, and cerebrospinal fluid markers revealed familial Creutzfeldt-Jakob disease. FDG PET with 3D-SSP disclosed that the hypometabolic pattern mimicked that of dementia with Lewy bodies. FDG PET with 3D-SSP can demonstrate similar patterns in various neurodegenerative disorders.

  20. Metabolic acidosis mimicking diabetic ketoacidosis after use of calorie-free mineral water.

    PubMed

    Dahl, Gry T; Woldseth, Berit; Lindemann, Rolf

    2012-09-01

    A previously healthy boy was admitted with fever, tachycardia, dyspnea, and was vomiting. A blood test showed a severe metabolic acidosis with pH 7.08 and an anion gap of 36 mmol/L. His urine had an odor of acetone. The serum glucose was 5.6 mmol/L, and no glucosuria was found. Diabetic ketoacidosis could therefore be eliminated. Lactate level was normal. Tests for the most common metabolic diseases were negative. Because of herpes stomatitis, the boy had lost appetite and only been drinking Diet Coke and water the last days. Diet Coke or Coca-Cola Light is sweetened with a blend containing cyclamates, aspartame, and acesulfame potassium, all free of calories. The etiology of the metabolic acidosis appeared to be a catabolic situation exaggerated by fasting with no intake of calories. The elevated anion gap was due to a severe starvation ketoacidosis, mimicking a diabetic ketoacidosis. Pediatricians should recommend carbohydrate/calorie-containing fluids for rehydration of children with acute fever, diarrhea, or illness.

  1. Construction and geometric stability of physiological flow rate wall-less stenosis phantoms.

    PubMed

    Ramnarine, K V; Anderson, T; Hoskins, P R

    2001-02-01

    Wall-less flow phantoms are preferred for ultrasound (US) because tissue-mimicking material (TMM) with good acoustical properties can be made and cast to form anatomical models. The construction and geometrical stability of wall-less TMM flow phantoms is described using a novel method of sealing to prevent leakage of the blood-mimicking fluid (BMF). Wall-less stenosis flow models were constructed using a robust agar-based TMM and sealed using reticulated foam at the inlet and outlet tubes. There was no BMF leakage at the highest flow rate of 2.8 L/min in 0%, 35% and 57% diameter reduction stenoses models. Failure of the 75% stenosis model, due to TMM fracture, occurred at maximum flow rate of 2 L/min (mean velocity 10 m/s within the stenosis). No change of stenosis geometry was measured over 4 days. The construction is simple and effective and extends the possibility for high flow rate studies using robust TMM wall-less phantoms.

  2. Computational modelling for the embolization of brain arteriovenous malformations.

    PubMed

    Orlowski, Piotr; Summers, Paul; Noble, J Alison; Byrne, James; Ventikos, Yiannis

    2012-09-01

    Treatment of arteriovenous malformations (AVMs) of the brain often requires the injection of a liquid embolic material to reduce blood flow through the malformation. The type of the liquid and the location of injection have to be carefully planned in a pre-operative manner. We introduce a new model of the interaction of liquid embolic materials with blood for the simulation of their propagation and solidification in the AVM. Solidification is mimicked by an increase of the material's viscosity. Propagation is modelled by using the concept of two-fluids modelling and that of scalar transport. The method is tested on digital phantoms and on one anatomically derived patient AVM case. Simulations showed that intuitive behaviour of the two-fluid system can be confirmed and that two types of glue propagation through the malformation can be reproduced. Distinction between the two types of propagation could be used to identify fistulous and plexiform compartments composing the AVM and to characterize the solidification of the embolic material in them. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  3. Biomarkers of Guillain-Barré Syndrome: Some Recent Progress, More Still to Be Explored

    PubMed Central

    Wang, Ying; Sun, Shuang; Zhu, Jie; Cui, Li; Zhang, Hong-Liang

    2015-01-01

    Guillain-Barré syndrome (GBS), the axonal subtype of which is mainly triggered by C. jejuni with ganglioside-mimicking lipooligosaccharides (LOS), is an immune-mediated disorder in the peripheral nervous system (PNS) accompanied by the disruption of the blood-nerve barrier (BNB) and the blood-cerebrospinal fluid barrier (B-CSF-B). Biomarkers of GBS have been extensively explored and some of them are proved to assist in the clinical diagnosis and in monitoring disease progression as well as in assessing the efficacy of immunotherapy. Herein, we systemically review the literature on biomarkers of GBS, including infection-/immune-/BNB, B-CSF-B, and PNS damage-associated biomarkers, aiming at providing an overview of GBS biomarkers and guiding further investigations. Furthermore, we point out further directions for studies on GBS biomarkers. PMID:26451079

  4. Heparin-mimicking multilayer coating on polymeric membrane via LbL assembly of cyclodextrin-based supramolecules.

    PubMed

    Deng, Jie; Liu, Xinyue; Ma, Lang; Cheng, Chong; Shi, Wenbin; Nie, Chuanxiong; Zhao, Changsheng

    2014-12-10

    In this study, multifunctional and heparin-mimicking star-shaped supramolecules-deposited 3D porous multilayer films with improved biocompatibility were fabricated via a layer-by-layer (LbL) self-assembly method on polymeric membrane substrates. Star-shaped heparin-mimicking polyanions (including poly(styrenesulfonate-co-sodium acrylate; Star-PSS-AANa) and poly(styrenesulfonate-co-poly(ethylene glycol)methyl ether methacrylate; Star-PSS-EGMA)) and polycations (poly(methyl chloride-quaternized 2-(dimethylamino)ethyl methacrylate; Star-PMeDMA) were first synthesized by atom transfer radical polymerization (ATRP) from β-cyclodextrin (β-CD) based cores. Then assembly of 3D porous multilayers onto polymeric membrane surfaces was carried out by alternating deposition of the polyanions and polycations via electrostatic interaction. The surface morphology and composition, water contact angle, blood activation, and thrombotic potential as well as cell viability for the coated heparin-mimicking films were systematically investigated. The results of surface ATR-FTIR spectra and XPS spectra verified successful deposition of the star-shaped supramolecules onto the biomedical membrane surfaces; scanning electron microscopy (SEM) and atomic force microscopy (AFM) observations revealed that the modified substrate had 3D porous surface morphology, which might have a great biological influence on the biointerface. Furthermore, systematic in vitro investigation of protein adsorption, platelet adhesion, human platelet factor 4 (PF4, indicates platelet activation), activate partial thromboplastin time (APTT), thrombin time (TT), coagulation activation (thrombin-antithrombin III complex (TAT, indicates blood coagulant)), and blood-related complement activation (C3a and C5a, indicates inflammation potential) confirmed that the heparin-mimicking multilayer coated membranes exhibited ultralow blood component activations and excellent hemocompatibility. Meanwhile, after surface coating, endothelial cell viability was also promoted, which indicated that the heparin-mimicking multilayer coating might extend the application fields of polymeric membranes in biomedical fields.

  5. Performance evaluation of photoacoustic oximetry imaging systems using a dynamic blood flow phantom with tunable oxygen saturation

    NASA Astrophysics Data System (ADS)

    Vogt, William C.; Zhou, Xuewen; Andriani, Rudy; Wear, Keith A.; Garra, Brian S.; Pfefer, Joshua

    2018-02-01

    Photoacoustic Imaging (PAI) is an emerging technology with strong potential for broad clinical applications from breast cancer detection to cerebral monitoring due to its ability to compute maps of blood oxygen saturation (SO2) distribution in deep tissues using multispectral imaging. However, no well-validated consensus test methods currently exist for evaluating oximetry-specific performance characteristics of PAI devices. We have developed a phantombased flow system capable of rapid SO2 adjustment to serve as a test bed for elucidation of factors impacting SO2 measurement and quantitative characterization of device performance. The flow system is comprised of a peristaltic pump, membrane oxygenator, oxygen and nitrogen gas, and in-line oxygen, pH, and temperature sensors that enable real-time estimation of SO2 reference values. Bovine blood was delivered through breast-relevant tissue phantoms containing vessel-mimicking fluid channels, which were imaged using a custom multispectral PAI system. Blood was periodically drawn for SO2 measurement in a clinical-grade CO-oximeter. We used this flow phantom system to evaluate the impact of device parameters (e.g.,wavelength-dependent fluence corrections) and tissue parameters (e.g. fluid channel depth, blood SO2, spectral coloring artifacts) on oximetry measurement accuracy. Results elucidated key challenges in PAI oximetry and device design trade-offs, which subsequently allowed for optimization of system performance. This approach provides a robust benchtop test platform that can support PAI oximetry device optimization, performance validation, and clinical translation, and may inform future development of consensus test methods for performance assessment of photoacoustic oximetry imaging systems.

  6. Dynamics of blood flow in a microfluidic ladder network

    NASA Astrophysics Data System (ADS)

    Maddala, Jeevan; Zilberman-Rudenko, Jevgenia; McCarty, Owen

    The dynamics of a complex mixture of cells and proteins, such as blood, in perturbed shear flow remains ill-defined. Microfluidics is a promising technology for improving the understanding of blood flow under complex conditions of shear; as found in stent implants and in tortuous blood vessels. We model the fluid dynamics of blood flow in a microfluidic ladder network with dimensions mimicking venules. Interaction of blood cells was modeled using multiagent framework, where cells of different diameters were treated as spheres. This model served as the basis for predicting transition regions, collision pathways, re-circulation zones and residence times of cells dependent on their diameters and device architecture. Based on these insights from the model, we were able to predict the clot formation configurations at various locations in the device. These predictions were supported by the experiments using whole blood. To facilitate platelet aggregation, the devices were coated with fibrillar collagen and tissue factor. Blood was perfused through the microfluidic device for 9 min at a physiologically relevant venous shear rate of 600 s-1. Using fluorescent microscopy, we observed flow transitions near the channel intersections and at the areas of blood flow obstruction, which promoted larger thrombus formation. This study of integrating model predictions with experimental design, aids in defining the dynamics of blood flow in microvasculature and in development of novel biomedical devices.

  7. A Microfluidics-based Pulpal Arteriole Blood Flow Phantom for Validation of Doppler Ultrasound Devices in Pulpal Blood Flow Velocity Measurement.

    PubMed

    Kim, Dohyun; Park, Sung-Ho

    2016-11-01

    Recently, Doppler ultrasound has been used for the measurement of pulpal blood flow in human teeth. However, the reliability of this method has not been verified. In this study, we developed a model to simulate arteriole blood flow within the dental pulp by using microfluidics. This arteriole simulator, or flow phantom, was used to determine the reliability of measurements obtained by using a Doppler ultrasound device. A microfluidic chip was fabricated by using the soft lithography technique, and blood-mimicking fluid was pumped through the channel by a microfluidic system. A Doppler ultrasound device was used for the measurement of flow velocity. The peak, mean, and minimal flow velocities obtained from the phantom and the Doppler ultrasound device were compared by using linear regression analysis and Pearson correlation coefficient. Bland-Altman analyses were performed to evaluate the velocity differences between the flow generated by the phantom and the flow measurements made with the Doppler ultrasound device. The microfluidic system was able to generate the flow profiles as intended, and the fluid flow could be monitored and controlled by the software program. There were excellent linear correlations between the peak, mean, and minimal flow velocities of the phantom and those of the Doppler ultrasound device (r = 0.94-0.996, P < .001). However, the velocities were overestimated by the Doppler ultrasound device. This phantom provides opportunities for research and education involving the Doppler ultrasound technique in dentistry. Although Doppler ultrasound can be an effective tool for the measurement of pulpal blood flow velocity, it is essential to validate and calibrate the device before clinical use. Copyright © 2016 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  8. Incubation under fluid dynamic conditions markedly improves the structural preservation in vitro of explanted skeletal muscles.

    PubMed

    Carton, Flavia; Calderan, Laura; Malatesta, Manuela

    2017-11-28

    Explanted organs and tissues represent suitable experimental systems mimicking the functional and structural complexity of the living organism, with positive ethical and economic impact on research activities. However, their preservation in culture is generally limited, thus hindering their application as experimental models for biomedical research. In the present study, we investigated the potential of an innovative fluid dynamic culture system to improve the structural preservation in vitro of explanted mouse skeletal muscles (soleus). We used light and transmission electron microscopy to compare the morphological features of muscles maintained either in multiwell plates under conventional conditions or in a bioreactor mimicking the flow of physiological fluids. Our results demonstrate that fluid dynamic conditions markedly slowed the progressive structural deterioration of the muscle tissue occurring during the permanence in the culture medium, prolonging the preservation of some organelles such as mitochondria up to 48 h.

  9. Incubation under fluid dynamic conditions markedly improves the structural preservation in vitro of explanted skeletal muscles

    PubMed Central

    Carton, Flavia; Calderan, Laura; Malatesta, Manuela

    2017-01-01

    Explanted organs and tissues represent suitable experimental systems mimicking the functional and structural complexity of the living organism, with positive ethical and economic impact on research activities. However, their preservation in culture is generally limited, thus hindering their application as experimental models for biomedical research. In the present study, we investigated the potential of an innovative fluid dynamic culture system to improve the structural preservation in vitro of explanted mouse skeletal muscles (soleus). We used light and transmission electron microscopy to compare the morphological features of muscles maintained either in multiwell plates under conventional conditions or in a bioreactor mimicking the flow of physiological fluids. Our results demonstrate that fluid dynamic conditions markedly slowed the progressive structural deterioration of the muscle tissue occurring during the permanence in the culture medium, prolonging the preservation of some organelles such as mitochondria up to 48 h. PMID:29313601

  10. A composite chitosan-gelatin bi-layered, biomimetic macroporous scaffold for blood vessel tissue engineering.

    PubMed

    Badhe, Ravindra V; Bijukumar, Divya; Chejara, Dharmesh R; Mabrouk, Mostafa; Choonara, Yahya E; Kumar, Pradeep; du Toit, Lisa C; Kondiah, Pierre P D; Pillay, Viness

    2017-02-10

    A composite chitosan-gelatin macroporous hydrogel-based scaffold with bi-layered tubular architecture was engineered by solvent casting-co-particulate leaching. The scaffold constituted an inner macroporous layer concealed by a non-porous outer layer mimicking the 3D matrix of blood vessels with cellular adhesion and proliferation. The scaffold was evaluated for its morphological, physicochemical, physicomechanical and biodurability properties employing SEM, FTIR, DSC, XRD, porositometry, rheology and texture analysis. The fluid uptake and biodegradation in the presence of lysozymes was also investigated. Cellular attachment and proliferation was analysed using human dermal fibroblasts (HDF-a) seeded onto the scaffold and evaluated by MTT assay, SEM, and confocal microscopy. Results demonstrated that the scaffold had a desirable tensile strength=95.81±11kPa, elongation at break 112.5±13%, porosity 82% and pores between 100 and 230μm, 50% in vitro biodegradation at day 16 and proliferated fibroblasts over 20 days. These results demonstrate that scaffold may be an excellent tubular archetype for blood vessel tissue engineering. Copyright © 2016 Elsevier Ltd. All rights reserved.

  11. Pseudolipomatosis in Endometrial Specimens Does Not Represent Uterine Perforation.

    PubMed

    Heller, Alexis

    2017-02-01

    Specimens of endometrial biopsies can sometimes present with an artifact within blood, composed of optically clear vacuoles mimicking adipose tissue, pseudolipomatosis. This artifact can be mistaken for adipose tissue and lead to an overdiagnosis of uterine perforation. We describe the case of pseudolipomatosis seen within the evacuated products of conception from a missed abortion. Areas of vacuolization in the blood clot mimicked adipose tissue. However, the vacuoles varied in size and did not contain adipocytes. Familiarity with this artifact will lead to avoidance of overdiagnosis of adipose tissue and uterine perforation in curettage specimens.

  12. Elevated thyroid peroxidase antibodies with encephalopathy in MELAS syndrome.

    PubMed

    Chan, Derrick W S; Lim, C C Tchoyoson; Tay, Stacey K H; Choong, Chew-Thye; Phuah, Huan Kee

    2007-06-01

    Both the syndrome of mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes (MELAS syndrome) and Hashimoto's encephalopathy can present with nonspecific encephalopathy. Hashimoto's encephalopathy is an association of steroid-responsive encephalopathy with elevated thyroid peroxidase antibodies. Steroid-responsive encephalopathy, however, is not characteristic of the MELAS syndrome, which typically presents with stroke-like episodes and lactic acidosis in cerebrospinal fluid and blood. Here, a patient is described with goiter, recurrent encephalopathy and elevated thyroid peroxidase antibodies who apparently responded to steroid therapy; however, magnetic resonance imaging was atypical for Hashimoto's encephalopathy, and she was diagnosed with MELAS syndrome. This syndrome can present with apparent steroid-responsive encephalopathy and elevated thyroid peroxidase antibodies, mimicking Hashimoto's encephalopathy, and should be suspected if lactic acidosis is present and typical features are detected on magnetic resonance imaging.

  13. Prototype of an opto-capacitive probe for non-invasive sensing cerebrospinal fluid circulation

    NASA Astrophysics Data System (ADS)

    Myllylä, Teemu; Vihriälä, Erkki; Pedone, Matteo; Korhonen, Vesa; Surazynski, Lukasz; Wróbel, Maciej; Zienkiewicz, Aleksandra; Hakala, Jaakko; Sorvoja, Hannu; Lauri, Janne; Fabritius, Tapio; Jedrzejewska-Szczerska, Małgorzata; Kiviniemi, Vesa; Meglinski, Igor

    2017-03-01

    In brain studies, the function of the cerebrospinal fluid (CSF) awakes growing interest, particularly related to studies of the glymphatic system in the brain, which is connected with the complex system of lymphatic vessels responsible for cleaning the tissues. The CSF is a clear, colourless liquid including water (H2O) approximately with a concentration of 99 %. In addition, it contains electrolytes, amino acids, glucose, and other small molecules found in plasma. The CSF acts as a cushion behind the skull, providing basic mechanical as well as immunological protection to the brain. Disturbances of the CSF circulation have been linked to several brain related medical disorders, such as dementia. Our goal is to develop an in vivo method for the non-invasive measurement of cerebral blood flow and CSF circulation by exploiting optical and capacitive sensing techniques simultaneously. We introduce a prototype of a wearable probe that is aimed to be used for long-term brain monitoring purposes, especially focusing on studies of the glymphatic system. In this method, changes in cerebral blood flow, particularly oxy- and deoxyhaemoglobin, are measured simultaneously and analysed with the response gathered by the capacitive sensor in order to distinct the dynamics of the CSF circulation behind the skull. Presented prototype probe is tested by measuring liquid flows inside phantoms mimicking the CSF circulation.

  14. Teaching Radioactive Decay and Radiometric Dating: An Analog Activity Based on Fluid Dynamics

    ERIC Educational Resources Information Center

    Claiborne, Lily L.; Miller, Calvin F.

    2012-01-01

    We present a new laboratory activity for teaching radioactive decay by using hydrodynamic processes as an analog and an evaluation of its efficacy in the classroom. A fluid flowing from an upper beaker into a lower beaker (shampoo in this case) behaves mathematically identically to radioactive decay, mimicking the exponential decay process,…

  15. Computational Fluid Dynamics of Developing Avian Outflow Tract Heart Valves

    PubMed Central

    Bharadwaj, Koonal N.; Spitz, Cassie; Shekhar, Akshay; Yalcin, Huseyin C.; Butcher, Jonathan T.

    2012-01-01

    Hemodynamic forces play an important role in sculpting the embryonic heart and its valves. Alteration of blood flow patterns through the hearts of embryonic animal models lead to malformations that resemble some clinical congenital heart defects, but the precise mechanisms are poorly understood. Quantitative understanding of the local fluid forces acting in the heart has been elusive because of the extremely small and rapidly changing anatomy. In this study, we combine multiple imaging modalities with computational simulation to rigorously quantify the hemodynamic environment within the developing outflow tract (OFT) and its eventual aortic and pulmonary valves. In vivo Doppler ultrasound generated velocity profiles were applied to Micro-Computed Tomography generated 3D OFT lumen geometries from Hamburger-Hamilton (HH) stage 16 to 30 chick embryos. Computational fluid dynamics simulation initial conditions were iterated until local flow profiles converged with in vivo Doppler flow measurements. Results suggested that flow in the early tubular OFT (HH16 and HH23) was best approximated by Poiseuille flow, while later embryonic OFT septation (HH27, HH30) was mimicked by plug flow conditions. Peak wall shear stress (WSS) values increased from 18.16 dynes/cm2 at HH16 to 671.24 dynes/cm2 at HH30. Spatiotemporally averaged WSS values also showed a monotonic increase from 3.03 dynes/cm2 at HH16 to 136.50 dynes/cm2 at HH30. Simulated velocity streamlines in the early heart suggest a lack of mixing, which differed from classical ink injections. Changes in local flow patterns preceded and correlated with key morphogenetic events such as OFT septation and valve formation. This novel method to quantify local dynamic hemodynamics parameters affords insight into sculpting role of blood flow in the embryonic heart and provides a quantitative baseline dataset for future research. PMID:22535311

  16. Automatic Emboli Detection System for the Artificial Heart

    NASA Astrophysics Data System (ADS)

    Steifer, T.; Lewandowski, M.; Karwat, P.; Gawlikowski, M.

    In spite of the progress in material engineering and ventricular assist devices construction, thromboembolism remains the most crucial problem in mechanical heart supporting systems. Therefore, the ability to monitor the patient's blood for clot formation should be considered an important factor in development of heart supporting systems. The well-known methods for automatic embolus detection are based on the monitoring of the ultrasound Doppler signal. A working system utilizing ultrasound Doppler is being developed for the purpose of flow estimation and emboli detection in the clinical artificial heart ReligaHeart EXT. Thesystem will be based on the existing dual channel multi-gate Doppler device with RF digital processing. A specially developed clamp-on cannula probe, equipped with 2 - 4 MHz piezoceramic transducers, enables easy system setup. We present the issuesrelated to the development of automatic emboli detection via Doppler measurements. We consider several algorithms for the flow estimation and emboli detection. We discuss their efficiency and confront them with the requirements of our experimental setup. Theoretical considerations are then met with preliminary experimental findings from a) flow studies with blood mimicking fluid and b) in-vitro flow studies with animal blood. Finally, we discuss some more methodological issues - we consider several possible approaches to the problem of verification of the accuracy of the detection system.

  17. Super-Anticoagulant Heparin-Mimicking Hydrogel Thin Film Attached Substrate Surfaces to Improve Hemocompatibility.

    PubMed

    He, Min; Cui, Xiaofei; Jiang, Huiyi; Huang, Xuelian; Zhao, Weifeng; Zhao, Changsheng

    2017-02-01

    In this study, heparin-mimicking hydrogel thin films are covalently attached onto poly(ether sulfone) membrane surfaces to improve anticoagulant property. The hydrogel films display honeycomb-like porous structure with well controlled thickness and show long-term stability. After immobilizing the hydrogel films, the membranes show excellent anticoagulant property confirmed by the activated partial thromboplastin time values exceeding 600 s. Meanwhile, the thrombin time values increase from 20 to 61 s as the sodium allysulfonate proportions increase from 0 to 80 mol%. In vitro investigations of protein adsorption and blood-related complement activation also confirm that the membranes exhibit super-anticoagulant property. Furthermore, gentamycin sulfate is loaded into the hydrogel films, and the released drug shows significant inhibition toward E. coli bacteria. It is believed that the surface attached heparin-mimicking hydrogel thin films may show high potential for the applications in various biological fields, such as blood contacting materials and drug loading materials. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Coexistence and interfacial properties of a triangle-well mimicking the Lennard-Jones fluid and a comparison with noble gases.

    PubMed

    Bárcenas, M; Reyes, Y; Romero-Martínez, A; Odriozola, G; Orea, P

    2015-02-21

    Coexistence and interfacial properties of a triangle-well (TW) fluid are obtained with the aim of mimicking the Lennard-Jones (LJ) potential and approach the properties of noble gases. For this purpose, the scope of the TW is varied to match vapor-liquid densities and surface tension. Surface tension and coexistence curves of TW systems with different ranges were calculated with replica exchange Monte Carlo and compared to those data previously reported in the literature for truncated and shifted (STS), truncated (ST), and full Lennard-Jones (full-LJ) potentials. We observed that the scope of the TW potential must be increased to approach the STS, ST, and full-LJ properties. In spite of the simplicity of TW expression, a remarkable agreement is found. Furthermore, the variable scope of the TW allows for a good match of the experimental data of argon and xenon.

  19. Trapping of Embolic Particles in a Vessel Phantom by Cavitation-Enhanced Acoustic Streaming

    PubMed Central

    Maxwell, Adam D.; Park, Simone; Vaughan, Benjamin L.; Cain, Charles A.; Grotberg, James B.; Xu, Zhen

    2014-01-01

    Cavitation clouds generated by short, high-amplitude, focused ultrasound pulses were previously observed to attract, trap, and erode thrombus fragments in a vessel phantom. This phenomenon may offer a noninvasive method to capture and eliminate embolic fragments flowing through the bloodstream during a cardiovascular intervention. In this article, the mechanism of embolus trapping was explored by particle image velocimetry (PIV). PIV was used to examine the fluid streaming patterns generated by ultrasound in a vessel phantom with and without crossflow of blood-mimicking fluid. Cavitation enhanced streaming, which generated fluid vortices adjacent to the focus. The focal streaming velocity, uf, was as high as 120 cm/s, while mean crossflow velocities, uc, were imposed up to 14 cm/s. When a solid particle 3-4 mm diameter was introduced into crossflow, it was trapped near the focus. Increasing uf promoted particle trapping while increasing uc promoted particle escape. The maximum crossflow Reynolds number at which particles could be trapped, Rec, was approximately linear with focal streaming number, Ref, i.e. Rec = 0.25Ref + 67.44 (R2=0.76) corresponding to dimensional velocities uc=0.084uf + 3.122 for 20 < uf < 120 cm/s. The fluidic pressure map was estimated from PIV and indicated a negative pressure gradient towards the focus, trapping the embolus near this location. PMID:25109407

  20. Mimicking bug-like surface structures and their fluid transport produced by ultrashort laser pulse irradiation of steel

    NASA Astrophysics Data System (ADS)

    Kirner, S. V.; Hermens, U.; Mimidis, A.; Skoulas, E.; Florian, C.; Hischen, F.; Plamadeala, C.; Baumgartner, W.; Winands, K.; Mescheder, H.; Krüger, J.; Solis, J.; Siegel, J.; Stratakis, E.; Bonse, J.

    2017-12-01

    Ultrashort laser pulses with durations in the fs-to-ps range were used for large area surface processing of steel aimed at mimicking the morphology and extraordinary wetting behaviour of bark bugs (Aradidae) found in nature. The processing was performed by scanning the laser beam over the surface of polished flat sample surfaces. A systematic variation of the laser processing parameters (peak fluence and effective number of pulses per spot diameter) allowed the identification of different regimes associated with characteristic surface morphologies (laser-induced periodic surface structures, i.e., LIPSS, grooves, spikes, etc.). Moreover, different laser processing strategies, varying laser wavelength, pulse duration, angle of incidence, irradiation atmosphere, and repetition rates, allowed to achieve a range of morphologies that resemble specific structures found on bark bugs. For identifying the ideal combination of parameters for mimicking bug-like structures, the surfaces were inspected by scanning electron microscopy. In particular, tilted micrometre-sized spikes are the best match for the structure found on bark bugs. Complementary to the morphology study, the wetting behaviour of the surface structures for water and oil was examined in terms of philic/phobic nature and fluid transport. These results point out a route towards reproducing complex surface structures inspired by nature and their functional response in technologically relevant materials.

  1. Blood-Vessel Mimicking Structures by Stereolithographic Fabrication of Small Porous Tubes Using Cytocompatible Polyacrylate Elastomers, Biofunctionalization and Endothelialization

    PubMed Central

    Huber, Birgit; Engelhardt, Sascha; Meyer, Wolfdietrich; Krüger, Hartmut; Wenz, Annika; Schönhaar, Veronika; Tovar, Günter E. M.; Kluger, Petra J.; Borchers, Kirsten

    2016-01-01

    Blood vessel reconstruction is still an elusive goal for the development of in vitro models as well as artificial vascular grafts. In this study, we used a novel photo-curable cytocompatible polyacrylate material (PA) for freeform generation of synthetic vessels. We applied stereolithography for the fabrication of arbitrary 3D tubular structures with total dimensions in the centimeter range, 300 µm wall thickness, inner diameters of 1 to 2 mm and defined pores with a constant diameter of approximately 100 µm or 200 µm. We established a rinsing protocol to remove remaining cytotoxic substances from the photo-cured PA and applied thio-modified heparin and RGDC-peptides to functionalize the PA surface for enhanced endothelial cell adhesion. A rotating seeding procedure was introduced to ensure homogenous endothelial monolayer formation at the inner luminal tube wall. We showed that endothelial cells stayed viable and adherent and aligned along the medium flow under fluid-flow conditions comparable to native capillaries. The combined technology approach comprising of freeform additive manufacturing (AM), biomimetic design, cytocompatible materials which are applicable to AM, and biofunctionalization of AM constructs has been introduced as BioRap® technology by the authors. PMID:27104576

  2. A theoretical and experimental investigation of nonlinear propagation of ultrasound through tissue mimicking media

    NASA Astrophysics Data System (ADS)

    Rielly, Matthew Robert

    An existing numerical model (known as the Bergen code) is used to investigate finite amplitude ultrasound propagation through multiple layers of tissue-like media. This model uses a finite difference method to solve the nonlinear parabolic KZK wave equation. The code is modified to include an arbitrary frequency dependence of absorption and transmission effects for wave propagation across a plane interface at normal incidence. In addition the code is adapted to calculate the total intensity loss associated with the absorption of the fundamental and nonlinearly generated harmonics. Measurements are also taken of the axial nonlinear pressure field generated from a circular focused, 2.25 MHz source, through single and multiple layered tissue mimicking fluids, for source pressures in the range from 13 kPa to 310 kPa. Two tissue mimicking fluids are developed to provide acoustic properties similar to amniotic fluid and a typical soft tissue. The values of the nonlinearity parameter, sound velocity and frequency dependence of attenuation for both fluids are presented, and the measurement procedures employed to obtain these characteristics are described in detail. These acoustic parameters, together with the measured source conditions are used as input to the numerical model, allowing the experimental conditions to be simulated. Extensive comparisons are made between the model's predictions and the axial pressure field measurements. Results are presented in the frequency domain showing the fundamental and three subsequent harmonic amplitudes on axis, as a function of axial distance. These show that significant nonlinear distortion can occur through media with characteristics typical of tissue. Time domain waveform comparisons are also made. An excellent agreement is found between theory and experiment indicating that the model can be used to predict nonlinear ultrasound propagation through multiple layers of tissue-like media. The numerical code is also used to model the intensity loss through layered tissue mimics and results are presented illustrating the effects of altering the layered medium on the magnitude and spatial distribution of intensity loss.

  3. Design and in vivo evaluation of a patch delivery system for insulin based on thiolated polymers.

    PubMed

    Grabovac, Vjera; Föger, Florian; Bernkop-Schnürch, Andreas

    2008-02-04

    The aim of this study was to develop and evaluate a novel three-layered oral delivery system for insulin in vivo. The patch system consisted of a mucoadhesive layer, a water insoluble backing layer made of ethylcellulose and an enteric coating made of Eudragit. Drug release studies were performed in media mimicking stomach and intestinal fluids. For in vivo studies patch systems were administered orally to conscious non-diabetic rats. Orally administered insulin in aqueous solution was used as control. After the oral administration of the patch systems a decrease of glucose and increase of insulin blood levels were measured. The mucoadhesive layer, exhibiting a diameter of 2.5mm and a weight of 5mg, comprised polycarbophil-cysteine conjugate (49%), bovine insulin (26%), gluthatione (5%) and mannitol (20%). 74.8+/-4.8% of insulin was released from the delivery system over 6h. Six hours after administration of the patch system mean maximum decrease of blood glucose level of 31.6% of the initial value could be observed. Maximum insulin concentration in blood was 11.3+/-6.2ng/ml and was reached 6h after administration. The relative bioavailability of orally administered patch system versus subcutaneous injection was 2.2%. The results indicate that the patch system provides enhancement of intestinal absorption and thereby offers a promising strategy for peroral peptide delivery.

  4. Traumatic head injury mimicking acute encephalopathy with biphasic seizures and late reduced diffusion.

    PubMed

    Inoue, Hirofumi; Hasegawa, Shunji; Kajimoto, Madoka; Matsushige, Takeshi; Ichiyama, Takashi

    2014-10-01

    Many studies have reported acute encephalopathy with biphasic seizures and late reduced diffusion (AESD) associated with viral infection at onset, but few studies have reported AESD without infection. We report the case of a 9-month-old boy who had a clinical course mimicking AESD after a traffic accident. The traffic accident caused a mild subdural hematoma without neurological abnormalities on admission. The boy became unconscious on the second day, and he was diagnosed with non-convulsive status epilepticus on the third day. Diffusion-weighted imaging showed reduced water diffusion in the subcortical white matter. On laboratory analysis interleukin (IL)-6 was elevated in the cerebrospinal fluid (CSF), but not in the serum. He had severe neurological sequelae with mental retardation, spastic tetraplegia, and epilepsy. We suggest that brain damage mimicking AESD was caused by the traffic accident and the prolonged seizure during infancy. © 2014 Japan Pediatric Society.

  5. Hypomyelination, memory impairment, and blood-brain barrier permeability in a model of sleep apnea.

    PubMed

    Kim, Lenise Jihe; Martinez, Denis; Fiori, Cintia Zappe; Baronio, Diego; Kretzmann, Nélson Alexandre; Barros, Helena Maria Tannhauser

    2015-02-09

    We investigated the effect of intermittent hypoxia, mimicking sleep apnea, on axonal integrity, blood-brain barrier permeability, and cognitive function of mice. Forty-seven C57BL mice were exposed to intermittent or sham hypoxia, alternating 30s of progressive hypoxia and 30s of reoxigenation, during 8h/day. The axonal integrity in cerebellum was evaluated by transmission electron microscopy. Short- and long-term memories were assessed by novel object recognition test. The levels of endothelin-1 were measured by ELISA. Blood-brain barrier permeability was quantified by Evans Blue dye. After 14 days, animals exposed to intermittent hypoxia showed hypomyelination in cerebellum white matter and higher serum levels of endothelin-1. The short and long-term memories in novel object recognition test was impaired in the group exposed to intermittent hypoxia as compared to controls. Blood-brain barrier permeability was similar between the groups. These results indicated that hypomyelination and impairment of short- and long-term working memories occurred in C57BL mice after 14 days of intermittent hypoxia mimicking sleep apnea. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Post-pancreatitis Fat Necrosis Mimicking Carcinomatosis.

    PubMed

    Smith, Joshua P; Arnoletti, J Pablo; Varadarajulu, Shyam; Morgan, Desiree E

    2008-01-01

    Acute pancreatitis can result in retroperitoneal fat necrosis, typically occurring in the peripancreatic region, with extension into the transverse mesocolon, omentum and mesenteric root. When evaluated with contrast enhanced computed tomography (CECT), acute peripancreatic post necrotic collections typically become lower in attenuation over time, and often appear as homogeneous fluid collections. Saponification as a complication of fat necrosis in patients with acute pancreatitis is a well recognized clinical entity. While retroperitonal fat necrosis is commonly seen on CECT, saponification is not a prominent imaging feature. We present a case of acute pancreatitis complicated by extensive saponification of fat throughout the retroperitoneum and peritoneal lining, mimicking carcinomatosis.

  7. Ehrlichia Meningitis Mimicking Aneurysmal Subarachnoid Hemorrhage: A Case Study for Medical Decision-Making Heuristics.

    PubMed

    Dredla, Brynn; Freeman, William D

    2016-04-01

    Thunderclap headache is a sudden and severe headache that can occur after an aneurysmal subarachnoid hemorrhage (SAH). Subarachnoid hemorrhage is a medical emergency that requires prompt attention and hospitalization. Patients with thunderclap headache often undergo a noncontrast head computed tomography (CT) scan to ascertain SAH bleeding and, if the scan is negative, then undergo a lumbar puncture to look for cerebrospinal fluid (CSF) red blood cells (RBCs), which would be consistent with an aneurysmal leak. If the initial CT is negative and CSF is positive for RBCs, patients are usually admitted to the hospital for evaluation of intracranial aneurysm. We encountered a patient with thunderclap headache whose initial head CT was negative for SAH and whose CSF tested positive for RBCs. The patient was referred to our center for evaluation and management of aneurysmal SAH. However, on careful review of the patient's medical history, serum laboratory values, and spinal fluid values, the patient was diagnosed with Ehrlichia chaffeensis meningitis. While Ehrlichia meningitis is rare, it is important to recognize the clinical clues that could help avoid formal cerebral angiography, a costly and potentially unnecessary procedure. We present how this case represented a cognitive framing bias and anchoring heuristic as well as steps that medical providers can use to prevent such cognitive errors in diagnosis.

  8. Biorelevant media resistant co-culture model mimicking permeability of human intestine.

    PubMed

    Antoine, Delphine; Pellequer, Yann; Tempesta, Camille; Lorscheidt, Stefan; Kettel, Bernadette; Tamaddon, Lana; Jannin, Vincent; Demarne, Frédéric; Lamprecht, Alf; Béduneau, Arnaud

    2015-03-15

    Cell culture models are currently used to predict absorption pattern of new compounds and formulations in the human gastro-intestinal tract (GIT). One major drawback is the lack of relevant apical incubation fluids allowing mimicking luminal conditions in the GIT. Here, we suggest a culture model compatible with biorelevant media, namely Fasted State Simulated Intestinal Fluid (FaSSIF) and Fed State Simulated Intestinal Fluid (FeSSIF). Co-culture was set up from Caco-2 and mucus-secreting HT29-MTX cells using an original seeding procedure. Viability and cytotoxicity assays were performed following incubation of FeSSIF and FaSSIF with co-culture. Influence of biorelevant fluids on paracellular permeability or transporter proteins were also evaluated. Results were compared with Caco-2 and HT29-MTX monocultures. While Caco-2 viability was strongly affected with FeSSIF, no toxic effect was detected for the co-cultures in terms of viability and lactate dehydrogenase release. The addition of FeSSIF to the basolateral compartment of the co-culture induced cytotoxic effects which suggested the apical mucus barrier being cell protective. In contrast to FeSSIF, FaSSIF induced a slight increase of the paracellular transport and both tested media inhibited partially the P-gp-mediated efflux in the co-culture. Additionally, the absorptive transport of propranolol hydrochloride, a lipophilic β-blocker, was strongly affected by biorelevant fluids. This study demonstrated the compatibility of the Caco-2/HT29-MTX model with some of the current biorelevant media. Combining biorelevant intestinal fluids with features such as mucus secretion, adjustable paracellular and P-gp mediated transports, is a step forward to more realistic in-vitro models of the human intestine. Copyright © 2015. Published by Elsevier B.V.

  9. Investigation of transverse oscillation method.

    PubMed

    Udesen, Jesper; Jensen, Jørgen Arendt

    2006-05-01

    Conventional ultrasound scanners can display only the axial component of the blood velocity vector, which is a significant limitation when vessels nearly parallel to the skin surface are scanned. The transverse oscillation (TO) method overcomes this limitation by introducing a TO and an axial oscillation in the pulse echo field. The theory behind the creation of the double oscillation pulse echo field is explained as well as the theory behind the estimation of the vector velocity. A parameter study of the method is performed, using the ultrasound simulation program Field II. A virtual linear-array transducer with center frequency 7 MHz and 128 active elements is created, and a virtual blood vessel of radius 6.4 mm is simulated. The performance of the TO method is found around an initial point in the parameter space. The parameters varied are: flow angle, transmit focus depth, receive apodization, pulse length, transverse wave length, number of emissions, signal-to-noise ratio (SNR), and type of echo-canceling filter used. Using an experimental scanner, the performance of the TO method is evaluated. An experimental flowrig is used to create laminar parabolic flow in a blood mimicking fluid, and the fluid is scanned under different flow-to-beam angles. The relative standard deviation on the transverse velocity estimate is found to be less than 10% for all angles between 50 degrees and 90 degrees. Furthermore, the TO method is evaluated in the flowrig using pulsatile flow, which resembles the flow in the femoral artery. The estimated volume flow as a function of time is compared to the volume flow derived from a conventional axial method at a flow-to-beam angle of 60 degrees. It is found that the method is highly sensitive to the angle between the flow and the beam direction. Also, the choice of echo canceling filter affects the performance significantly.

  10. Trajectory control of PbSe–γ-Fe2O3 nanoplatforms under viscous flow and an external magnetic field

    PubMed Central

    Etgar, Lioz; Nakhmani, Arie; Tannenbaum, Allen; Lifshitz, Efrat; Tannenbaum, Rina

    2010-01-01

    The flow behavior of nanostructure clusters, consisting of chemically bonded PbSe quantum dots and magnetic γ -Fe2O3 nanoparticles, has been investigated. The clusters are regarded as model nanoplatforms with multiple functionalities, where the γ -Fe2O3 magnets serve as transport vehicles, manipulated by an external magnetic field gradient, and the quantum dots act as fluorescence tags within an optical window in the near-infrared regime. The clusters’ flow was characterized by visualizing their trajectories within a viscous fluid (mimicking a blood stream), using an optical imaging method, while the trajectory pictures were analyzed by a specially developed processing package. The trajectories were examined under various flow rates, viscosities and applied magnetic field strengths. The results revealed a control of the trajectories even at low magnetic fields (<1 T), validating the use of similar nanoplatforms as active targeting constituents in personalized medicine. PMID:20368678

  11. Tubular collagen scaffolds with radial elasticity for hollow organ regeneration.

    PubMed

    Versteegden, Luuk R; van Kampen, Kenny A; Janke, Heinz P; Tiemessen, Dorien M; Hoogenkamp, Henk R; Hafmans, Theo G; Roozen, Edwin A; Lomme, Roger M; van Goor, Harry; Oosterwijk, Egbert; Feitz, Wout F; van Kuppevelt, Toin H; Daamen, Willeke F

    2017-04-01

    Tubular collagen scaffolds have been used for the repair of damaged hollow organs in regenerative medicine, but they generally lack the ability to reversibly expand in radial direction, a physiological characteristic seen in many native tubular organs. In this study, tubular collagen scaffolds were prepared that display a shape recovery effect and therefore exhibit radial elasticity. Scaffolds were constructed by compression of fibrillar collagen around a star-shaped mandrel, mimicking folds in a lumen, a typical characteristic of empty tubular hollow organs, such as ureter or urethra. Shape recovery effect was introduced by in situ fixation using a star-shaped mandrel, 3D-printed clamps and cytocompatible carbodiimide crosslinking. Prepared scaffolds expanded upon increase of luminal pressure and closed to the star-shaped conformation after removal of pressure. In this study, we applied this method to construct a scaffold mimicking the dynamics of human urethra. Radial expansion and closure of the scaffold could be iteratively performed for at least 1000 cycles, burst pressure being 132±22mmHg. Scaffolds were seeded with human epithelial cells and cultured in a bioreactor under dynamic conditions mimicking urination (pulse flow of 21s every 2h). Cells adhered and formed a closed luminal layer that resisted flow conditions. In conclusion, a new type of a tubular collagen scaffold has been constructed with radial elastic-like characteristics based on the shape of the scaffold, and enabling the scaffold to reversibly expand upon increase in luminal pressure. These scaffolds may be useful for regenerative medicine of tubular organs. In this paper, a new type I collagen-based tubular scaffold is presented that possesses intrinsic radial elasticity. This characteristic is key to the functioning of a number of tubular organs including blood vessels and organs of the gastrointestinal and urogenital tract. The scaffold was given a star-shaped lumen by physical compression and chemical crosslinking, mimicking the folding pattern observed in many tubular organs. In rest, the lumen is closed but it opens upon increase of luminal pressure, e.g. when fluids pass. Human epithelial cells seeded on the luminal side adhered well and were compatible with voiding dynamics in a bioreactor. Collagen scaffolds with radial elasticity may be useful in the regeneration of dynamic tubular organs. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. Duration of time on shift before accidental blood or body fluid exposure for housestaff, nurses, and technicians.

    PubMed

    Green-McKenzie, Judith; Shofer, Frances S

    2007-01-01

    Shift work has been found to be associated with an increased rate of errors and accidents among healthcare workers (HCWs), but the effect of shift work on accidental blood and body fluid exposure sustained by HCWs has not been well characterized. To determine the duration of time on shift before accidental blood and body fluid exposure in housestaff, nurses, and technicians and the proportion of housestaff who sustain a blood and body fluid exposure after 12 hours on duty. This retrospective, descriptive study was conducted during a 24-month period at a large urban teaching hospital. Participants were HCWs who sustained an accidental blood and body fluid exposure. Housestaff were on duty significantly longer than both nursing staff (P=.02) and technicians (P<.0001) before accidental blood and body fluid exposure. Half of the blood and body fluid exposures sustained by housestaff occurred after being on duty 8 hours or more, and 24% were sustained after being on duty 12 hours or more. Of all HCWs, 3% reported an accidental blood and body fluid exposure, with specific rates of 7.9% among nurses, 9.4% among housestaff, and 3% among phlebotomists. Housestaff were significantly more likely to have longer duration of time on shift before blood and body fluid exposure than were the other groups. Almost one-quarter of accidental blood and body fluid exposures to housestaff were incurred after they had been on duty for 12 hours or more. Housestaff sustained a higher rate of accidental blood and body fluid exposures than did nursing staff and technicians.

  13. Involvement of Cerebellum in Leigh Syndrome: Case Report and Review of the Literature.

    PubMed

    Chourasia, Nitish; Adejumo, Rahmat B; Patel, Rajan P; Koenig, Mary Kay

    2017-09-01

    Leigh syndrome is an early-onset progressive neurodegenerative disorder typically involving lesions of the bilateral basal ganglia, thalami, and brainstem. Isolated involvement of the cerebellum is uncommon. We present a six-year-old boy with Leigh syndrome who presented with recurrent episodes of ataxia and dysarthria. He was diagnosed with Leigh syndrome at two years of age with bilateral basal ganglia lesions on brain magnetic resonance imaging (MRI). Genetic testing confirmed a diagnosis of Leigh syndrome secondary to a homoplasmic mitochondrial DNA mutation (m.9176T>C). He experienced regressive episodes (ages five and six years). Each regressive episode had a similar presentation with worsening of baseline ataxia and dysarthria. The first episode mimicked infectious cerebellitis, with elevated cerebral spinal fluid (CSF) protein and white blood cell count. No organisms were isolated from the CSF/blood during any of the regressive episodes. Brain MRI consistently showed cerebellar lesions, however cerebellar spectroscopy during the second episode found an elevated lactate peak, a decrease of the N-acetylaspartate peak, and elevation of the choline peak; consistent with an acute exacerbation of Leigh syndrome. Leigh syndrome can present primarily with involvement of the cerebellum, and it should be considered in the differential diagnosis for acute cerebellitis. Published by Elsevier Inc.

  14. Effect of pre-donation fluid intake on fluid shift from interstitial to intravascular compartment in blood donors.

    PubMed

    Deepika, Chenna; Murugesan, Mohandoss; Shastry, Shamee

    2018-02-01

    Fluid shifts from interstitial to intravascular space during blood donation helps in compensating the lost blood volume. We aimed to determine the volume of fluid shift following donation in donors with and without pre-donation fluid intake. We studied the fluid shift in 325 blood donors prospectively. Donors were divided in groups- with no fluid intake (GI) and either water (GII) or oral rehydrating fluids (GIII) before donation. Fluid shift following donation was calculated based on the difference between the pre and post donation blood volume. The influence of oral fluid intake, age, gender and body mass index (BMI) on volume of fluid shift was analyzed. The fluid shift was significant between donors without fluids (GI: 127 ± 81 ml) and donors with fluid intake (GII & III: 96 ± 45 ml) (p < 0.05). The difference was not significant between donors with water intake (GII: 106 ± 52 ml) and oral rehydrating fluid intake (GIII: 87 ± 41 ml). The shifted fluid volume increased with increasing BMI and decreased with increasing age in females. The fluid shift increased in females than in males. The age, gender, BMI and VVR did not significantly contribute to the volume of fluid shift following donation. As per our observation, the oral fluids before donation might not contribute to increase in fluid shift in blood donors after donation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Anxiolytic-Like Actions of Fatty Acids Identified in Human Amniotic Fluid

    PubMed Central

    García-Ríos, Rosa Isela; Rodríguez-Landa, Juan Francisco; Contreras, Carlos M.

    2013-01-01

    Eight fatty acids (C12–C18) were previously identified in human amniotic fluid, colostrum, and milk in similar proportions but different amounts. Amniotic fluid is well known to be the natural environment for development in mammals. Interestingly, amniotic fluid and an artificial mixture of fatty acids contained in amniotic fluid produce similar anxiolytic-like actions in Wistar rats. We explored whether the lowest amount of fatty acids contained in amniotic fluid with respect to colostrum and milk produces such anxiolytic-like effects. Although a trend toward a dose-response effect was observed, only an amount of fatty acids that was similar to amniotic fluid fully mimicked the effect of diazepam (2 mg/kg, i.p.) in the defensive burying test, an action devoid of effects on locomotor activity and motor coordination. Our results confirm that the amount of fatty acids contained in amniotic fluid is sufficient to produce anxiolytic-like effects, suggesting similar actions during intrauterine development. PMID:23737729

  16. ACUTE HYDRONEPHROSIS MIMICKING RENAL COLIC

    PubMed Central

    Martin, Donald C.; Kaufman, Joseph J.

    1964-01-01

    Hydronephrosis may be acute, recurrent and related to ingestion of fluid. Frequently a lower polar vessel is an etiological factor. The condition is amenable to corrective operation by a variety of surgical techniques, as in the six cases here reported. ImagesFigure 1.Figure 2.Figure 3.Figure 4.Figure 5.Figure 6.Figure 7. PMID:14154288

  17. Regulation of enzyme activities in carnivorous pitcher plants of the genus Nepenthes.

    PubMed

    Saganová, Michaela; Bokor, Boris; Stolárik, Tibor; Pavlovič, Andrej

    2018-05-16

    Nepenthes regulates enzyme activities by sensing stimuli from the insect prey. Protein is the best inductor mimicking the presence of an insect prey. Carnivorous plants of the genus Nepenthes have evolved passive pitcher traps for prey capture. In this study, we investigated the ability of chemical signals from a prey (chitin, protein, and ammonium) to induce transcription and synthesis of digestive enzymes in Nepenthes × Mixta. We used real-time PCR and specific antibodies generated against the aspartic proteases nepenthesins, and type III and type IV chitinases to investigate the induction of digestive enzyme synthesis in response to different chemical stimuli from the prey. Transcription of nepenthesins was strongly induced by ammonium, protein and live prey; chitin induced transcription only very slightly. This is in accordance with the amount of released enzyme and proteolytic activity in the digestive fluid. Although transcription of type III chitinase was induced by all investigated stimuli, a significant accumulation of the enzyme in the digestive fluid was found mainly after protein and live prey addition. Protein and live prey were also the best inducers for accumulation of type IV chitinase in the digestive fluid. Although ammonium strongly induced transcription of all investigated genes probably through membrane depolarization, strong acidification of the digestive fluid affected stability and abundance of both chitinases in the digestive fluid. The study showed that the proteins are universal inductors of enzyme activities in carnivorous pitcher plants best mimicking the presence of insect prey. This is not surprising, because proteins are a much valuable source of nitrogen, superior to chitin. Extensive vesicular activity was observed in prey-activated glands.

  18. [A case of an anti-Ma2 antibody-positive patient presenting with variable CNS symptoms mimicking multiple system atrophy with a partial response to immunotherapy].

    PubMed

    Shiraishi, Wataru; Iwanaga, Yasutaka; Yamamoto, Akifumi

    2015-01-01

    A 70-year-old man with a 5-month history of progressive bradykinesia of the bilateral lower extremities was admitted to our hospital. At the age of 64, he underwent proximal gastrectomy for gastric cancer. He also had a history of subacute combined degeneration of the spinal cord since the age of 67, which was successfully treated with vitamin B12 therapy. Four weeks before admission to our hospital, he admitted himself to his former hospital complaining of walking difficulty. Two weeks later, however, his symptoms progressed rapidly; he was immobilized for two weeks and did not respond to the vitamin therapy. On admission to our hospital, he showed moderate paralysis of the lower extremities, cog-wheel rigidity of the four extremities, and dystonic posture of his left hand. He also showed orthostatic hypotension and vesicorectal disorders. Blood examination and cerebrospinal fluid analysis revealed no remarkable abnormalities. Electroencephalography showed frontal dominant, high voltage, sharp waves. His brain and spinal MRI revealed no notable abnormalities. We suspected autoimmune disease and commenced one course of intravenous methylprednisolone therapy, resulting in improvement of the parkinsonism and orthostatic hypotension. Based on these results, we investigated possible neural antigens and detected anti-Ma2 antibody. In addition to limbic encephalitis, anti-Ma2 antibody-positive neural disorders are characterized by rapid eye movement sleep behavior disorders or parkinsonism. Here, we report an anti-Ma2 antibody positive patient presenting variable CNS symptoms mimicking multiple system atrophy, who responded to immunotherapy.

  19. Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.

    PubMed

    Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil

    2016-11-01

    Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. Posterior reversible encephalopathy syndrome mimicking a left middle cerebral artery stroke.

    PubMed

    Terranova, Santo; Kumar, Jai Dev; Libman, Richard B

    2012-01-01

    Certain Acute Clinical presentations are highly suggestive of stroke caused by specific mechanisms. One example of this would be the sudden onset of aphasia without hemiparesis often reflecting cerebral embolism, frequently from a cardiac source. Posterior reversible encephalopathy syndrome (PRES) describes a usually reversible neurologic syndrome with a variety of presenting symptoms from headache, altered mental status, seizures, vomiting, diminished spontaneity and speech, abnormalities of visual perception and visual loss. We report a patient presenting with elevated blood pressure, CT characteristics of PRES but a highly circumscribed neurologic syndrome (Wernicke's Aphasia without hemiparesis) suggestive of a cardioembolic stroke affecting the left MCA territory. That is, PRES mimicked a focal stroke syndrome. The importance of recognizing this possibility is that his deficits resolved with blood pressure control, while other treatments, such as intensifying his anticoagulation would have been inappropriate. In addition, allowing his blood pressure to remain elevated as is often done in the setting of an acute stroke might have perpetuated the underlying pathophysiology of PRES leading to a worse clinical outcome. For this reason PRES needs to be recognized quickly and treated appropriately.

  1. Estimating equivalent cutoff thresholds for drugs in blood and oral fluid using prevalence regression: a study of tetrahydrocannabinol and amphetamine.

    PubMed

    Gjerde, Hallvard; Verstraete, Alain G

    2011-10-10

    To validate a method for determining equivalent drug cutoff concentrations for tetrahydrocannabinol and amphetamine in blood and oral fluid, which ensures that the drug prevalence in samples of blood and oral fluid taken simultaneously is equal. A method using regression analysis of drug concentrations for defined percentiles in blood and oral fluid was developed. The accuracy and precision of this technique was investigated. As study populations, 311 cannabis users and 197 amphetamine users from the Rosita-2 Project were used. A total of 80 paired oral fluid and blood concentrations were needed to determine accurate regression formulae. When using the formulae to calculate drug cutoff concentrations in oral fluid corresponding to 2.0, 4.0, 6.0, 8.0 and 10.0 ng/ml tetrahydrocannabinol in blood and 200, 400, 600, 800 and 1000 ng/ml amphetamine in blood, the accuracy was better than 100 ± 20% compared to actual prevalence in blood with precision better than ± 20%. Prevalence regression may be a useful tool in estimating equivalent cutoff concentrations in blood and oral fluid. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  2. Comparison of fluid types for resuscitation after acute blood loss in mallard ducks (Anas platyrhynchos).

    PubMed

    Lichtenberger, Marla; Orcutt, Connie; Cray, Carolyn; Thamm, Douglas H; DeBehnke, Daniel; Page, Cheryl; Mull, Lori; Kirby, Rebecca

    2009-10-01

    The purpose of this study was to determine the LD(50) for acute blood loss in mallard ducks (Anas platyrhynchos), compare the mortality rate among 3 fluid resuscitation groups, and determine the time required for a regenerative RBC response. Prospective study. Medical College of Wisconsin Research facility. Eighteen mallard ducks were included for the LD(50) study and 28 for the fluid resuscitation study. Phlebotomy was performed during both the LD(50) and fluid resuscitation studies. Ducks in the fluid resuscitation study received a 5 mL/kg intravenous bolus of crystalloids, hetastarch (HES), or a hemoglobin-based oxygen-carrying solution (HBOCS). The LD(50) for acute blood loss was 60% of total blood volume. This blood volume was removed in the fluid resuscitation study to create a model of acute blood loss. Following fluid administration, 6 birds in the crystalloid group (66%), 4 birds in the HES group (40%), and 2 birds in the HBOCS group (20%) died. No statistical difference in mortality rate was seen among the 3 fluid resuscitation groups. Relative polychromasia evaluated post-phlebotomy demonstrated regeneration starting at 24 hours and continuing through 48 hours. The LD(50) for acute blood loss in mallard ducks was 60% of their total blood volume. Although no statistical difference in mortality rate was appreciated among the 3 fluid resuscitation groups, a trend of decreased mortality rate was observed in the HBOCS group. An early regenerative response was apparent following acute blood loss.

  3. Hyaluronan supplementation as a mechanical regulator of cartilage tissue development under joint-kinematic-mimicking loading.

    PubMed

    Wu, Yabin; Stoddart, Martin J; Wuertz-Kozak, Karin; Grad, Sibylle; Alini, Mauro; Ferguson, Stephen J

    2017-08-01

    Articular cartilage plays an essential role in joint lubrication and impact absorption. Through this, the mechanical signals are coupled to the tissue's physiological response. Healthy synovial fluid has been shown to reduce and homogenize the shear stress acting on the cartilage surfaces due to its unique shear-thinning viscosity. As cartilage tissues are sensitive to mechanical changes in articulation, it was hypothesized that replacing the traditional culture medium with a healthy non-Newtonian lubricant could enhance tissue development in a cartilage engineering model, where joint-kinematic-mimicking mechanical loading is applied. Different amounts of hyaluronic acid were added to the culture medium to replicate the viscosities of synovial fluid at different health states. Hyaluronic acid supplementation, especially at a physiologically healthy concentration (2.0 mg ml -1 ), promoted a better preservation of chondrocyte phenotype. The ratio of collagen II to collagen I mRNA was 4.5 times that of the control group, implying better tissue development (however, with no significant difference of measured collagen II content), with a good retention of collagen II and proteoglycan in the mechanically active region. Simulating synovial fluid properties by hyaluronic acid supplementation created a favourable mechanical environment for mechanically loaded constructs. These findings may help in understanding the influence of joint articulation on tissue homeostasis, and moreover, improve methods for functional cartilage tissue engineering. © 2017 The Author(s).

  4. DNA methylation profiling for a confirmatory test for blood, saliva, semen, vaginal fluid and menstrual blood.

    PubMed

    Lee, Hwan Young; Jung, Sang-Eun; Lee, Eun Hee; Yang, Woo Ick; Shin, Kyoung-Jin

    2016-09-01

    The ability to predict the type of tissues or cells from molecular profiles of crime scene samples has important practical implications in forensics. A previously reported multiplex assay using DNA methylation markers could only discriminate between 4 types of body fluids: blood, saliva, semen, and the body fluid which originates from female reproductive organ. In the present study, we selected 15 menstrual blood-specific CpG marker candidates based on analysis of 12 genome-wide DNA methylation profiles of vaginal fluid and menstrual blood. The menstrual blood-specificity of the candidate markers was confirmed by comparison with HumanMethylation450 BeadChip array data obtained for 58 samples including 12 blood, 12 saliva, 12 semen, 3 vaginal fluid, and 19 skin epidermis samples. Among 15CpG marker candidates, 3 were located in the promoter region of the SLC26A10 gene, and 2 of them (cg09696411 and cg18069290) showed high menstrual blood specificity. DNA methylation at the 2CpG markers was further tested by targeted bisulfite sequencing of 461 additional samples including 49 blood, 52 saliva, 34 semen, 125 vaginal fluid, and 201 menstrual blood. Because the 2 markers showed menstrual blood-specific methylation patterns, we modified our previous multiplex methylation SNaPshot reaction to include these 2 markers. In addition, a blood marker cg01543184 with cross reactivity to semen was replaced with cg08792630, and a semen-specific unmethylation marker cg17621389 was removed. The resultant multiplex methylation SNaPshot allowed positive identification of blood, saliva, semen, vaginal fluid and menstrual blood using the 9CpG markers which show a methylation signal only in the target body fluids. Because of the complexity in cell composition, menstrual bloods produced DNA methylation profiles that vary with menstrual cycle and sample collection methods, which are expected to provide more insight into forensic menstrual blood test. Moreover, because the developed multiplex methylation SNaPshot reaction includes the 4CpG markers of which specificities have been confirmed by multiple studies, it will facilitate confirmatory tests for body fluids that are frequently observed in forensic casework. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  5. Directed Fluid Transport and Mixing with Biomimetic Cilia Arrays

    NASA Astrophysics Data System (ADS)

    Shields, A. R.; Evans, B. A.; Carstens, B. L.; Falvo, M. R.; Washburn, S.; Superfine, R.

    2009-03-01

    We present results on the long-range, directed fluid transport and fluidic mixing produced by the collective beating of arrays of biomimetic cilia. These artificial cilia are arrays of free-standing nanorods roughly the size of biological cilia, which we fabricate from a polymer-magnetic nanoparticle composite material and actuate with permanent magnets to mimic biological cilia. Biological cilia have evolved to produce microscale fluid transport and are increasingly being recognized as critical components in a wide range of biological systems. However, despite much effort cilia generated fluid flows remain an area of active study. In the last decade, cilia-driven fluid flow in the embryonic node of vertebrates has been implicated as the initial left-right symmetry breaking event in these embryos. With silia we generate directional fluid transport by mimicking the tilted conical beating of these nodal cilia. By seeding fluorescent microparticles into the fluid we have noted the existence of two distinct flow regimes. The fluid flow is directional and coherent above the cilia tips, while between the cilia tips and the floor particle motion is complicated and suggestive of chaotic advection.

  6. Application of a magnetic fluid seal to rotary blood pumps

    NASA Astrophysics Data System (ADS)

    Mitamura, Y.; Arioka, S.; Sakota, D.; Sekine, K.; Azegami, M.

    2008-05-01

    A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.

  7. Application of a magnetic fluid seal to rotary blood pumps.

    PubMed

    Mitamura, Y; Arioka, S; Sakota, D; Sekine, K; Azegami, M

    2008-05-21

    A magnetic fluid seal enables mechanical contact-free rotation of a shaft without frictional heat and material wear and hence has excellent durability. However, the durability of a magnetic fluid seal decreases in liquid. The life of a seal applied to a rotary blood pump is not known. We have developed a magnetic fluid seal that has a shield mechanism minimizing the influence of the rotary pump on the magnetic fluid. The developed magnetic fluid seal worked for over 286 days in a continuous flow condition, for 24 days (on-going) in a pulsatile flow condition and for 24 h (electively terminated) in blood flow. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.

  8. What Is Blood?

    MedlinePlus

    ... Blood / What is Blood? WHERE CAN I DONATE? Blood is the red fluid that circulates in our blood vessels, i. ... cells, white blood cells, and platelets. The remainder is a fluid called plasma. Blood cells are produced in bone marrow. Red cells, white cells and platelets are made in ...

  9. Pseudogout of the cervical and thoracic spine mimicking infection after lumbar fusion: case report.

    PubMed

    Bridges, Kelly J; Bullis, Carli L; Wanchu, Ajay; Than, Khoi D

    2017-08-01

    Pseudogout is a form of acute calcium pyrophosphate deposition (CPPD) disease that typically afflicts the elderly. CPPD commonly involves larger joints, such as the knees, wrists, shoulders, and hips, and has been known to involve the spine. The authors report the case of a 66-year-old woman with a recent history of lumbar laminectomy and fusion who presented 5 weeks postprocedure with a clinical and radiographic picture consistent with multilevel skip lesions involving the cervical and thoracic spine, thoracic discitis, and epidural abscess. Serial blood cultures and repeat biopsy samples were sterile. Subsequent wrist and ankle erythema, pain, and swelling led to synovial fluid analysis, and pseudogout was diagnosed. She was treated with an interleukin-1 inhibitor with immediate symptom relief. To the authors' knowledge, this is only the second report of spinal pseudogout presenting with a clinical and radiographic picture consistent with discitis and epidural abscess. This report is the first to report skip lesions of pseudogout occurring throughout the spine that are uniquely remote from a recent lumbar surgery.

  10. Antimicrobial Peptide Mimicking Primary Amine and Guanidine Containing Methacrylamide Copolymers Prepared by Raft Polymerization

    PubMed Central

    Exley, Sarah E.; Paslay, Lea C.; Sahukhal, Gyan S.; Abel, Brooks A.; Brown, Tyler D.; McCormick, Charles L.; Heinhorst, Sabine; Koul, Veena; Choudhary, Veena; Elasri, Mohamed O.; Morgan, Sarah E.

    2016-01-01

    Naturally occurring antimicrobial peptides (AMPs) display the ability to eliminate a wide variety of bacteria, without toxicity to the host eukaryotic cells. Synthetic polymers containing moieties mimicking lysine and arginine components found in AMPs have been reported to show effectiveness against specific bacteria, with the mechanism of activity purported to depend on the nature of the amino acid mimic. In an attempt to incorporate the antimicrobial activity of both amino acids into a single water-soluble copolymer, a series of copolymers containing lysine mimicking aminopropyl methacrylamide (APMA) and arginine mimicking guanadinopropyl methacrylamide (GPMA) were prepared via aqueous RAFT polymerization. Copolymers were prepared with varying ratios of the comonomers, with degree of polymerization of 35–40 and narrow molecular weight distribution to simulate naturally occurring AMPs. Antimicrobial activity was determined against Gram-negative and Gram-positive bacteria under conditions with varying salt concentration. Toxicity to mammalian cells was assessed by hemolysis of red blood cells and MTT assays of MCF-7 cells. Antimicrobial activity was observed for APMA homopolymer and copolymers with low concentrations of GPMA against all bacteria tested, with low toxicity toward mammalian cells. PMID:26558609

  11. Computer simulation of preflight blood volume reduction as a countermeasure to fluid shifts in space flight

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Srinivasan, R.; Charles, J. B.

    1992-01-01

    Fluid shifts in weightlessness may cause a central volume expansion, activating reflexes to reduce the blood volume. Computer simulation was used to test the hypothesis that preadaptation of the blood volume prior to exposure to weightlessness could counteract the central volume expansion due to fluid shifts and thereby attenuate the circulatory and renal responses resulting in large losses of fluid from body water compartments. The Guyton Model of Fluid, Electrolyte, and Circulatory Regulation was modified to simulate the six degree head down tilt that is frequently use as an experimental analog of weightlessness in bedrest studies. Simulation results show that preadaptation of the blood volume by a procedure resembling a blood donation immediately before head down bedrest is beneficial in damping the physiologic responses to fluid shifts and reducing body fluid losses. After ten hours of head down tilt, blood volume after preadaptation is higher than control for 20 to 30 days of bedrest. Preadaptation also produces potentially beneficial higher extracellular volume and total body water for 20 to 30 days of bedrest.

  12. A pacemaker powered by an implantable biofuel cell operating under conditions mimicking the human blood circulatory system--battery not included.

    PubMed

    Southcott, Mark; MacVittie, Kevin; Halámek, Jan; Halámková, Lenka; Jemison, William D; Lobel, Robert; Katz, Evgeny

    2013-05-07

    Biocatalytic electrodes made of buckypaper were modified with PQQ-dependent glucose dehydrogenase on the anode and with laccase on the cathode and were assembled in a flow biofuel cell filled with serum solution mimicking the human blood circulatory system. The biofuel cell generated an open circuitry voltage, Voc, of ca. 470 mV and a short circuitry current, Isc, of ca. 5 mA (a current density of 0.83 mA cm(-2)). The power generated by the implantable biofuel cell was used to activate a pacemaker connected to the cell via a charge pump and a DC-DC converter interface circuit to adjust the voltage produced by the biofuel cell to the value required by the pacemaker. The voltage-current dependencies were analyzed for the biofuel cell connected to an Ohmic load and to the electronic loads composed of the interface circuit, or the power converter, and the pacemaker to study their operation. The correct pacemaker operation was confirmed using a medical device - an implantable loop recorder. Sustainable operation of the pacemaker was achieved with the system closely mimicking human physiological conditions using a single biofuel cell. This first demonstration of the pacemaker activated by the physiologically produced electrical energy shows promise for future electronic implantable medical devices powered by electricity harvested from the human body.

  13. Experimental Validation of ARFI Surveillance of Subcutaneous Hemorrhage (ASSH) Using Calibrated Infusions in a Tissue-Mimicking Model and Dogs.

    PubMed

    Geist, Rebecca E; DuBois, Chase H; Nichols, Timothy C; Caughey, Melissa C; Merricks, Elizabeth P; Raymer, Robin; Gallippi, Caterina M

    2016-09-01

    Acoustic radiation force impulse (ARFI) Surveillance of Subcutaneous Hemorrhage (ASSH) has been previously demonstrated to differentiate bleeding phenotype and responses to therapy in dogs and humans, but to date, the method has lacked experimental validation. This work explores experimental validation of ASSH in a poroelastic tissue-mimic and in vivo in dogs. The experimental design exploits calibrated flow rates and infusion durations of evaporated milk in tofu or heparinized autologous blood in dogs. The validation approach enables controlled comparisons of ASSH-derived bleeding rate (BR) and time to hemostasis (TTH) metrics. In tissue-mimicking experiments, halving the calibrated flow rate yielded ASSH-derived BRs that decreased by 44% to 48%. Furthermore, for calibrated flow durations of 5.0 minutes and 7.0 minutes, average ASSH-derived TTH was 5.2 minutes and 7.0 minutes, respectively, with ASSH predicting the correct TTH in 78% of trials. In dogs undergoing calibrated autologous blood infusion, ASSH measured a 3-minute increase in TTH, corresponding to the same increase in the calibrated flow duration. For a measured 5% decrease in autologous infusion flow rate, ASSH detected a 7% decrease in BR. These tissue-mimicking and in vivo preclinical experimental validation studies suggest the ASSH BR and TTH measures reflect bleeding dynamics. © The Author(s) 2015.

  14. Diagnostic value of ex vivo pleural fluid interferon-gamma versus adapted whole-blood quantiferon-TB gold in tube assays in tuberculous pleural effusion

    PubMed Central

    Eldin, Eman N.; Omar, Asmaa; Khairy, Mahmoud; Mekawy, Adel H. M.; Ghanem, Maha K.

    2012-01-01

    BACKGROUND: Noninvasive diagnosis of pleural tuberculosis (TB) remains a challenge due to the paucibacillary nature of the disease. As Mycobacterium tuberculosis (MTB)-specific T cells are recruited into pleural space in TB effusion; their indirect detection may provide useful clinical information. OBJECTIVES: Evaluation of pleural fluid interferon (INF)-γ levels vs Quantiferon–TB Gold In tube assay (QFT- IT) in blood and its adapted variants, using pleural fluid or isolated pleural fluid cells in the diagnosis of pleural TB. METHODS: Thirty-eight patients with pleural effusion of unknown etiology presented at Assiut University Hospital, Egypt, were recruited. Blood and pleural fluid were collected at presentation for INF-γ assays. Ex vivo pleural fluid INF-γ levels, QFT-IT in blood and its adapted variants were compared with final diagnosis as confirmed by other tools including blind and/or thoracoscopic pleural biopsy. RESULTS: The final clinical diagnosis was TB in 20 (53%), malignancy in 10 (26%), and effusion due to other causes in eight patients (21%). Ex vivo pleural fluid INF-γ levels accurately identified TB in all patients and were superior to the QFT-IT assays using blood or pleural fluid (70 and 78% sensitivity, with 60 and 83% specificity, respectively). QFT-IT assay applied to isolated pleural fluid cells had 100% sensitivity and 72% specificity. The optimal cut-off obtained with ROC analysis was 0.73 for TB Gold assay in blood assay, 0.82 IU/ml for the cultured pleural fluid assay, and 0.94 for isolated pleural cells assay. CONCLUSION: The ex vivo pleural fluid INF-γ level is an accurate marker for the diagnosis of pleural TB. QFT- IT assay in peripheral blood or its adapted versions of the assay using pleural fluid and/or washed pleural fluid cells had no diagnostic advantage over pleural fluid INF-γ in the diagnosis of pleural TB. PMID:23189099

  15. N-methyl-d-aspartate (NMDA) receptor antibodies encephalitis mimicking an autistic regression.

    PubMed

    Hacohen, Yael; Wright, Sukhvir; Gadian, Jonathan; Vincent, Angela; Lim, Ming; Wassmer, Evangeline; Lin, Jean-Pierre

    2016-10-01

    Expressive dysphasia and mutism are common clinical features in children and adults with N-methyl-d-aspartate receptor antibodies (NMDAR-Ab) encephalitis, and are likely to result from NMDAR hypofunction. A prodromal loss of social and communication skills can typify that of an autistic regression, particularly when presenting under the age of 3 years. Here we describe two toddlers who presented with developmental regression, particularly of their social communication skills, mimicking an autistic regression, who were found to have NMDAR-Ab in the serum and cerebrospinal fluid. Although both patients had some other neurological features, they were subtle, which resulted in delayed diagnosis of NMDAR-Ab encephalitis. Importantly, immunotherapy was beneficial in both patients, with significant improvement of their language skills and behaviour. © 2016 Mac Keith Press.

  16. Transcapillary protein flux following blood volume modification in dog.

    PubMed

    Miki, K; Nose, H; Tanaka, Y; Morimoto, T

    1984-01-01

    The net fluid and protein movements between intravascular and interstitial space following blood withdrawal and retransfusion of 15% of circulating blood volume were measured in dogs using a continuous monitoring method of circulating blood volume. A significant (p less than 0.01) increase in transvascular fluid shift was observed after the start of blood withdrawal and a new equilibrium state was reached within 15 to 20 min. Associated with the fluid shift, a significant increase in plasma protein of about 1 g was observed. On the other hand, blood retransfusion caused significant (p less than 0.01) increases in the shift of fluid and protein from intravascular space to interstitial space. The magnitudes of the shift of fluid and protein were almost identical in both blood withdrawal and retransfusion. The Kedem-Katchalsky transport equation was applied to the results obtained in the present study in order to analyze the relative role of diffusion and convection and to estimate the reflection coefficient for protein. A significant (p less than 0.01) linear relationship was observed between fluid and protein movement. These results suggest that the convective process is involved in the shift of protein between intravascular and interstitial space observed after blood volume modification.

  17. Aldosterone and Renin Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... must be careful to maintain fluid and electrolyte balance. Kidney failure is a possible complication of Bartter ...

  18. Spectral Mining for Discriminating Blood Origins in the Presence of Substrate Interference via Attenuated Total Reflection Fourier Transform Infrared Spectroscopy: Postmortem or Antemortem Blood?

    PubMed

    Takamura, Ayari; Watanabe, Ken; Akutsu, Tomoko; Ikegaya, Hiroshi; Ozawa, Takeaki

    2017-09-19

    Often in criminal investigations, discrimination of types of body fluid evidence is crucially important to ascertain how a crime was committed. Compared to current methods using biochemical techniques, vibrational spectroscopic approaches can provide versatile applicability to identify various body fluid types without sample invasion. However, their applicability is limited to pure body fluid samples because important signals from body fluids incorporated in a substrate are affected strongly by interference from substrate signals. Herein, we describe a novel approach to recover body fluid signals that are embedded in strong substrate interferences using attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy and an innovative multivariate spectral processing. This technique supported detection of covert features of body fluid signals, and then identified origins of body fluid stains on substrates. We discriminated between ATR FT-IR spectra of postmortem blood (PB) and those of antemortem blood (AB) by creating a multivariate statistics model. From ATR FT-IR spectra of PB and AB stains on interfering substrates (polyester, cotton, and denim), blood-originated signals were extracted by a weighted linear regression approach we developed originally using principal components of both blood and substrate spectra. The blood-originated signals were finally classified by the discriminant model, demonstrating high discriminant accuracy. The present method can identify body fluid evidence independently of the substrate type, which is expected to promote the application of vibrational spectroscopic techniques in forensic body fluid analysis.

  19. A Hepatocyte-Mimicking Antidote for Alcohol Intoxication.

    PubMed

    Xu, Duo; Han, Hui; He, Yuxin; Lee, Harrison; Wu, Di; Liu, Fang; Liu, Xiangsheng; Liu, Yang; Lu, Yunfeng; Ji, Cheng

    2018-04-11

    Alcohol intoxication causes serious diseases, whereas current treatments are mostly supportive and unable to remove alcohol efficiently. Upon alcohol consumption, alcohol is sequentially oxidized to acetaldehyde and acetate by the endogenous alcohol dehydrogenase and aldehyde dehydrogenase, respectively. Inspired by the metabolism of alcohol, a hepatocyte-mimicking antidote for alcohol intoxication through the codelivery of the nanocapsules of alcohol oxidase (AOx), catalase (CAT), and aldehyde dehydrogenase (ALDH) to the liver, where AOx and CAT catalyze the oxidation of alcohol to acetaldehyde, while ALDH catalyzes the oxidation of acetaldehyde to acetate. Administered to alcohol-intoxicated mice, the antidote rapidly accumulates in the liver and enables a significant reduction of the blood alcohol concentration. Moreover, blood acetaldehyde concentration is maintained at an extremely low level, significantly contributing to liver protection. Such an antidote, which can eliminate alcohol and acetaldehyde simultaneously, holds great promise for the treatment of alcohol intoxication and poisoning and can provide therapeutic benefits. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Changes in the interstitial fluid and the muscle water in rabbits in hemorrhagic shock.

    PubMed Central

    Wolcott, M W; Malinin, T I; Wu, N M

    1976-01-01

    Dynamics and changes in the biochemical composition in the interstitial fluid and the muscle water were studied in hemorrhagic shock. The interstitial fluid was collected from implanted perforated capsules. Muscle biopsies were examined with regard to their water content by the steady state magnetic nuclear resonance spectroscopy. The consistent and what appears to be the most significant changes were the fall in the interstitial fluid pressures, the quantitative reduction of muscle water, a sharp fall in the blood and interstitial blood pH, the moderate hyperkalemia and lack of change in blood an interstitial fluid sodium, and the rise in blood glucose levels not accompanied by a rise in the interstitial fluid glucose levels. PMID:11754

  1. Influence of nanostructural environment and fluid flow on osteoblast-like cell behavior: a model for cell-mechanics studies.

    PubMed

    Prodanov, L; Semeins, C M; van Loon, J J W A; te Riet, J; Jansen, J A; Klein-Nulend, J; Walboomers, X F

    2013-05-01

    Introducing nanoroughness on various biomaterials has been shown to profoundly effect cell-material interactions. Similarly, physical forces act on a diverse array of cells and tissues. Particularly in bone, the tissue experiences compressive or tensile forces resulting in fluid shear stress. The current study aimed to develop an experimental setup for bone cell behavior, combining a nanometrically grooved substrate (200 nm wide, 50 nm deep) mimicking the collagen fibrils of the extracellular matrix, with mechanical stimulation by pulsatile fluid flow (PFF). MC3T3-E1 osteoblast-like cells were assessed for morphology, expression of genes involved in cell attachment and osteoblastogenesis and nitric oxide (NO) release. The results showed that both nanotexture and PFF did affect cellular morphology. Cells aligned on nanotexture substrate in a direction parallel to the groove orientation. PFF at a magnitude of 0.7 Pa was sufficient to induce alignment of cells on a smooth surface in a direction perpendicular to the applied flow. When environmental cues texture and flow were interacting, PFF of 1.4 Pa applied parallel to the nanogrooves initiated significant cellular realignment. PFF increased NO synthesis 15-fold in cells attached to both smooth and nanotextured substrates. Increased collagen and alkaline phosphatase mRNA expression was observed on the nanotextured substrate, but not on the smooth substrate. Furthermore, vinculin and bone sialoprotein were up-regulated after 1 h of PFF stimulation. In conclusion, the data show that interstitial fluid forces and structural cues mimicking extracellular matrix contribute to the final bone cell morphology and behavior, which might have potential application in tissue engineering. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. Blood and interstitial flow in the hierarchical pore space architecture of bone tissue.

    PubMed

    Cowin, Stephen C; Cardoso, Luis

    2015-03-18

    There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen and reduced nutrition. Within the bone, as within other tissues, substances pass from the blood through the arterial walls into the interstitial fluid. The movement of the interstitial fluid carries these substances to the cells within the bone and, at the same time, carries off the waste materials from the cells. Bone tissue would not live without these fluid movements. The development of a model for poroelastic materials with hierarchical pore space architecture for the description of blood flow and interstitial fluid flow in living bone tissue is reviewed. The model is applied to the problem of determining the exchange of pore fluid between the vascular porosity and the lacunar-canalicular porosity in bone tissue due to cyclic mechanical loading and blood pressure. These results are basic to the understanding of interstitial flow in bone tissue that, in turn, is basic to understanding of nutrient transport from the vasculature to the bone cells buried in the bone tissue and to the process of mechanotransduction by these cells. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Blood and Interstitial flow in the hierarchical pore space architecture of bone tissue

    PubMed Central

    Cowin, Stephen C.; Cardoso, Luis

    2015-01-01

    There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen and reduced nutrition. Within the bone, as within other tissues, substances pass from the blood through the arterial walls into the interstitial fluid. The movement of the interstitial fluid carries these substances to the cells within the bone and, at the same time, carries off the waste materials from the cells. Bone tissue would not live without these fluid movements. The development of a model for poroelastic materials with hierarchical pore space architecture for the description of blood flow and interstitial fluid flow in living bone tissue is reviewed. The model is applied to the problem of determining the exchange of pore fluid between the vascular porosity and the lacunar-canalicular porosity in bone tissue due to cyclic mechanical loading and blood pressure. These results are basic to the understanding of interstitial flow in bone tissue that, in turn, is basic to understanding of nutrient transport from the vasculature to the bone cells buried in the bone tissue and to the process of mechanotransduction by these cells. PMID:25666410

  4. Collection and analysis of peritoneal fluid from healthy llamas and alpacas.

    PubMed

    Cebra, Christopher K; Tornquist, Susan J; Reed, Shannon K

    2008-05-01

    To describe a technique for abdominocentesis in camelids and report peritoneal fluid biochemical and cytologic findings from healthy llamas and alpacas. Prospective study. Animals-17 adult llamas and 5 adult alpacas. Right paracostal abdominocentesis was performed. Peritoneal fluid was collected by gravity flow into tubes containing potassium-EDTA for cell count and cytologic evaluation and lithium heparin for biochemical analysis. Blood samples were collected via jugular venipuncture into heparinized tubes at the same time. Cytologic components were quantified. Fluid pH and concentrations of total carbon dioxide, sodium, potassium, chloride, lactate, and glucose were compared between peritoneal fluid and venous blood. All but 3 camelids had peritoneal fluid cell counts of < 3,000 nucleated cells/microL, with < 2,000 neutrophils/microL and < 1,040 large mononuclear cells/microL. All but 1 had peritoneal fluid protein concentrations of > or = 2.5 g/dL. Peritoneal fluid of camelids generally contained slightly less glucose, lactate, and sodium and roughly equal concentrations of potassium and chloride as venous blood. Peritoneal fluid was collected safely from healthy camelids. Compared with blood, peritoneal fluid usually had a low cell count and protein concentration, but some individuals had higher values. Electrolyte concentrations resembled those found in blood. High cell counts and protein concentrations found in peritoneal fluid of some healthy camelids may overlap with values found in diseased camelids, complicating interpretation of peritoneal fluid values.

  5. Acute respiratory distress syndrome mimickers lacking common risk factors of the Berlin definition.

    PubMed

    Gibelin, Aude; Parrot, Antoine; Maitre, Bernard; Brun-Buisson, Christian; Mekontso Dessap, Armand; Fartoukh, Muriel; de Prost, Nicolas

    2016-02-01

    Some patients presenting with acute respiratory failure and meeting the Berlin criteria for acute respiratory distress syndrome (ARDS) lack exposure to common risk factors (CRF). These so-called ARDS mimickers often lack histological diffuse alveolar damage. We aimed to describe such ARDS mimickers lacking CRF (ARDS CRF-) in comparison with others (ARDS CRF+). Retrospective study including all patients receiving invasive mechanical ventilation for ARDS admitted to the intensive care units (ICUs) of two tertiary care centers from January 2003 to December 2012. The prevalence of ARDS CRF- was 7.5 % (95 % CI [5.5-9.5]; n = 50/665). On the basis of medical history, bronchoalveolar lavage fluid cytology, and chest CT scan patterns, four etiological categories were identified: immune (n = 18; 36 %), drug-induced (n = 13; 26 %), malignant (n = 7; 14 %), and idiopathic (n = 12; 24 %). Although the ARDS CRF- patients had a lower logistic organ dysfunction score (4 [3-8] vs. 10 [6-13]; p < 0.0001) and less often shock upon ICU admission (44 vs. 80 %; p < 0.0001) than their counterparts, their overall ICU mortality rate was very high (66 % [46-74]), and the absence of CRF remained associated with ICU mortality by multivariable logistic regression analysis (adjusted OR = 2.06; 95 % CI [1.02-4.18]; p = 0.044). Among ARDS CRF- patients, the presence of potentially reversible lung lesions with corticosteroids (aOR = 0.14; 95 % CI [0.03-0.62]) was associated with ICU survival. The absence of CRF among patients with ARDS is common and associated with a higher risk of mortality. For such atypical ARDS, a complete diagnostic workup, including bronchoalveolar lavage fluid cytology and chest CT scan patterns, should be performed to identify those patients who might benefit from specific therapies, including corticosteroids.

  6. Fluid balance within the canine anterolateral compartment and its relationship to compartment syndromes.

    PubMed

    Hargens, A R; Akeson, W H; Mubarak, S J; Owen, C A; Evans, K L; Garetto, L P; Gonsalves, M R; Schmidt, D A

    1978-06-01

    Fluid homeostasis within muscle compartments is maintained by four pressures: capillary blood pressure, capillary blood oncotic pressure, tissue-fluid pressure, and tissue fluid oncotic pressure. As determined in the canine anterolateral compartment, capillary blood pressure is 25 +/- 3 millimeters of mercury; capillary blood oncotic pressure, 26 +/- 3 millimeters of mercury, tissue-pbessure, -2 +/- 2 millimeters of mercury; and tissue-fluid oncotic pressure, 11 +/- 1 millimeters of mercury. The wick technique allows direct measurement of tissue-fluid pressure in skeletal muscle and, with minor modifications, is adapted to collect microsamples of interstitial fluid for determinations of tissue-fluid oncotic pressure. The wick technique detects very slight fluctuations in intracompartmental pressure such as light finger compression, injection of small volumes of fluid, and even pulsation due to adjacent arterial pressure. Adjacent muscle compartments may contain different tissue-fluid pressure due to impermeable osseofascial barriers. Our results obtained in canine muscle compartments pressurized by infusion of autologous plasma suggest that risks of muscle damage are significant at intracompartmental pressures greater than thirty millimeters of mercury.

  7. Scholte wave generation during single tracking location shear wave elasticity imaging of engineered tissues.

    PubMed

    Mercado, Karla P; Langdon, Jonathan; Helguera, María; McAleavey, Stephen A; Hocking, Denise C; Dalecki, Diane

    2015-08-01

    The physical environment of engineered tissues can influence cellular functions that are important for tissue regeneration. Thus, there is a critical need for noninvasive technologies capable of monitoring mechanical properties of engineered tissues during fabrication and development. This work investigates the feasibility of using single tracking location shear wave elasticity imaging (STL-SWEI) for quantifying the shear moduli of tissue-mimicking phantoms and engineered tissues in tissue engineering environments. Scholte surface waves were observed when STL-SWEI was performed through a fluid standoff, and confounded shear moduli estimates leading to an underestimation of moduli in regions near the fluid-tissue interface.

  8. Directed Fluid Transport with Biomimetic ``Silia'' Arrays

    NASA Astrophysics Data System (ADS)

    Shields, A. R.; Evans, B. A.; Carstens, B. L.; Falvo, M. R.; Washburn, S.; Superfine, R.

    2008-10-01

    We present results on the long-range, directed fluid transport produced by the collective beating of arrays of biomimetic ``silia.'' Silia are arrays of free-standing nanorods roughly the size of biological cilia, which we fabricate from a polymer-magnetic nanoparticle composite material. With external permanent magnets we actuate our silia such that their motion mimics the beating of biological cilia. Biological cilia have evolved to produce microscale fluid transport and are increasingly being recognized as critical components in a wide range of biological systems. However, despite much effort cilia generated fluid flows remain an area of active study. In the last decade, cilia-driven fluid flow in the embryonic node of vertebrates has been implicated as the initial left-right symmetry breaking event in these embryos. With silia we generate directional fluid transport by mimicking the tilted conical beating of these nodal cilia and seek to answer open questions about the nature of particle advection in such a system. By seeding fluorescent microparticles into the fluid we have noted the existence of two distinct flow regimes. The fluid flow is directional and coherent above the tips of the silia, while between the silia tips and floor particle motion is complicated and suggestive of chaotic advection.

  9. Imaging of Posttraumatic Arthritis, Avascular Necrosis, Septic Arthritis, Complex Regional Pain Syndrome, and Cancer Mimicking Arthritis.

    PubMed

    Rupasov, Andrey; Cain, Usa; Montoya, Simone; Blickman, Johan G

    2017-09-01

    This article focuses on the imaging of 5 discrete entities with a common end result of disability: posttraumatic arthritis, a common form of secondary osteoarthritis that results from a prior insult to the joint; avascular necrosis, a disease of impaired osseous blood flow, leading to cellular death and subsequent osseous collapse; septic arthritis, an infectious process leading to destructive changes within the joint; complex regional pain syndrome, a chronic limb-confined painful condition arising after injury; and cases of cancer mimicking arthritis, in which the initial findings seem to represent arthritis, despite a more insidious cause. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Crohn's disease-associated interstitial lung disease mimicking sarcoidosis: a case report and review of the literature.

    PubMed

    Thao, Choua; Lagstein, Amir; Allen, Tadashi; Dincer, Huseyin Erhan; Kim, Hyun Joo

    2016-10-07

    Respiratory involvement in Crohn's disease (CD) is a rare manifestation known to involve the large and small airways, lung parenchyma, and pleura. The clinical presentation is nonspecific, and diagnostic tests can mimic other pulmonary diseases, posing a diagnostic challenge and delay in treatment. We report a case of a 60-year-old female with a history of CD and psoriatic arthritis who presented with dyspnea, fever, and cough with abnormal radiological findings. Diagnostic testing revealed an elevated CD4:CD8 ratio in the bronchoalveolar lavage fluid, and cryoprobe lung biopsy results showed non-necrotizing granulomatous inflammation. We describe here the second reported case of pulmonary involvement mimicking sarcoidosis in Crohn's disease and a review of the literature on the approaches to making a diagnosis of CD-associated interstitial lung disease.

  11. Mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes (MELAS) syndrome mimicking herpes simplex encephalitis on imaging studies.

    PubMed

    Gieraerts, Christopher; Demaerel, Philippe; Van Damme, Philip; Wilms, Guido

    2013-01-01

    We present a case in which mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes syndrome mimicked the clinical and radiological signs of herpes simplex encephalitis. In a patient with subacute encephalopathy, on computed tomography and magnetic resonance imaging, lesions were present in both temporal lobes extending to both insular regions with sparing of the lentiform nuclei and in both posterior straight and cingulate gyri. Final diagnosis of mitochondrial encephalomyopathy, lactic acidosis, and stroke-like episodes syndrome was based on biochemical investigations on cerebrospinal fluid, electromyogram, muscle biopsy, and genetic analysis. On diffusion-weighted imaging, diffusion restriction was present in some parts of the lesions but not throughout the entire lesions. We suggest that this could be an important sign in the differential diagnosis with herpes simplex encephalitis.

  12. Development of a magnetic fluid shaft seal for an axial-flow blood pump.

    PubMed

    Sekine, Kazumitsu; Mitamura, Yoshinori; Murabayashi, Shun; Nishimura, Ikuya; Yozu, Ryouhei; Kim, Dong-Wook

    2003-10-01

    A rotating impeller in a rotary blood pump requires a supporting system in blood, such as a pivot bearing or magnetic suspension. To solve potential problems such as abrasive wear and complexity of a supporting system, a magnetic fluid seal was developed for use in an axial-flow blood pump. Sealing pressures at motor speeds of up to 8,000 rpm were measured with the seal immersed in water or bovine blood. The sealing pressure was about 200 mm Hg in water and blood. The calculated theoretical sealing pressure was about 230 mm Hg. The seal remained perfect for 743 days in a static condition and for 180+ days (ongoing test) at a motor speed of 7,000 rpm. Results of measurement of cell growth activity indicated that the magnetic fluid has no negative cytological effects. The specially designed magnetic fluid shaft seal is useful for an axial-flow blood pump.

  13. In vivo flow speed measurement of capillaries by photoacoustic correlation spectroscopy.

    PubMed

    Chen, Sung-Liang; Xie, Zhixing; Carson, Paul L; Wang, Xueding; Guo, L Jay

    2011-10-15

    We recently proposed photoacoustic correlation spectroscopy (PACS) and demonstrated a proof-of-concept experiment. Here we use the technique for in vivo flow speed measurement in capillaries in a chick embryo model. The photoacoustic microscopy system is used to render high spatial resolution and high sensitivity, enabling sufficient signals from single red blood cells. The probe beam size is calibrated by a blood-mimicking phantom. The results indicate the feasibility of using PACS to study flow speeds in capillaries.

  14. Blood glucose level reconstruction as a function of transcapillary glucose transport.

    PubMed

    Koutny, Tomas

    2014-10-01

    A diabetic patient occasionally undergoes a detailed monitoring of their glucose levels. Over the course of a few days, a monitoring system provides a detailed track of their interstitial fluid glucose levels measured in their subcutaneous tissue. A discrepancy in the blood and interstitial fluid glucose levels is unimportant because the blood glucose levels are not measured continuously. Approximately five blood glucose level samples are taken per day, and the interstitial fluid glucose level is usually measured every 5min. An increased frequency of blood glucose level sampling would cause discomfort for the patient; thus, there is a need for methods to estimate blood glucose levels from the glucose levels measured in subcutaneous tissue. The Steil-Rebrin model is widely used to describe the relationship between blood and interstitial fluid glucose dynamics. However, we measured glucose level patterns for which the Steil-Rebrin model does not hold. Therefore, we based our research on a different model that relates present blood and interstitial fluid glucose levels to future interstitial fluid glucose levels. Using this model, we derived an improved model for calculating blood glucose levels. In the experiments conducted, this model outperformed the Steil-Rebrin model while introducing no additional requirements for glucose sample collection. In subcutaneous tissue, 26.71% of the calculated blood glucose levels had absolute values of relative differences from smoothed measured blood glucose levels less than or equal to 5% using the Steil-Rebrin model. However, the same difference interval was encountered in 63.01% of the calculated blood glucose levels using the proposed model. In addition, 79.45% of the levels calculated with the Steil-Rebrin model compared with 95.21% of the levels calculated with the proposed model had 20% difference intervals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Manipulating the structure and mechanical properties of thermoplastic polyurethane/polycaprolactone hybrid small diameter vascular scaffolds fabricated via electrospinning using an assembled rotating collector.

    PubMed

    Mi, Hao-Yang; Jing, Xin; Yu, Emily; Wang, Xiaofeng; Li, Qian; Turng, Lih-Sheng

    2018-02-01

    The success of blood vessel transplants with vascular scaffolds (VSs) highly depends on their structure and mechanical properties. The fabrication of small diameter vascular scaffolds (SDVSs) mimicking the properties of native blood vessels has been a challenge. Herein, we propose a facile method to fabricate thermoplastic polyurethane (TPU)/polycaprolactone (PCL) hybrid SDVSs via electrospinning using a modified rotating collector. By varying the ratio between the TPU and the PCL, and changing the electrospinning volume, SDVSs with a wavy configuration and different properties could be obtained. Detailed investigation revealed that certain TPU/PCL hybrid SDVSs closely resembled the mechanical behaviors of blood vessels due to the presence of a wavy region and the combination of flexible TPU and rigid PCL, which mimicked the properties of elastin and collagen in blood vessels. The fabricated TPU/PCL SDVSs achieved lumen diameters of 1-3mm, wall thicknesses of 100-570µm, circumferential moduli of 1-6MPa, ultimate strengths of 2-8MPa, over 250% elongation-at-break values, toe regions of 5.3-9.4%, high recoverability, and compliances close to those of human veins. Moreover, these TPU/PCL SDVSs possessed sufficient suture retention strength and burst pressure to fulfill transplantation requirements and maintain normal blood flow. Human endothelial cell culture revealed good biocompatibility of the scaffolds, and cells were able to grow on the inner surface of the tubular scaffolds, indicating promising prospects for use as tissue-engineered vascular grafts. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Study of blood flow in several benchmark micro-channels using a two-fluid approach.

    PubMed

    Wu, Wei-Tao; Yang, Fang; Antaki, James F; Aubry, Nadine; Massoudi, Mehrdad

    2015-10-01

    It is known that in a vessel whose characteristic dimension (e.g., its diameter) is in the range of 20 to 500 microns, blood behaves as a non-Newtonian fluid, exhibiting complex phenomena, such as shear-thinning, stress relaxation, and also multi-component behaviors, such as the Fahraeus effect, plasma-skimming, etc. For describing these non-Newtonian and multi-component characteristics of blood, using the framework of mixture theory, a two-fluid model is applied, where the plasma is treated as a Newtonian fluid and the red blood cells (RBCs) are treated as shear-thinning fluid. A computational fluid dynamic (CFD) simulation incorporating the constitutive model was implemented using OpenFOAM® in which benchmark problems including a sudden expansion and various driven slots and crevices were studied numerically. The numerical results exhibited good agreement with the experimental observations with respect to both the velocity field and the volume fraction distribution of RBCs.

  17. Plume Splitting in a Two-layer Stratified Ambient Fluid

    NASA Astrophysics Data System (ADS)

    Ma, Yongxing; Flynn, Morris; Sutherland, Bruce

    2017-11-01

    A line-source plume descending into a two-layer stratified ambient fluid in a finite sized tank is studied experimentally. Although the total volume of ambient fluid is fixed, lower- and upper-layer fluids are respectively removed and added at a constant rate mimicking marine outfall through diffusers and natural and hybrid ventilated buildings. The influence of the plume on the ambient depends on the value of λ, defined as the ratio of the plume buoyancy to the buoyancy loss of the plume as it crosses the ambient interface. Similar to classical filling-box experiments, the plume can always reach the bottom of the tank if λ > 1 . By contrast, if λ < 1 , an intermediate layer eventually forms as a result of plume splitting. Eventually all of the plume fluid spreads within the intermediate layer. The starting time, tv, and the ending time, tt, of the transition process measured from experiments correlate with the value of λ. A three-layer ambient fluid is observed after transition, and the mean value of the measured densities of the intermediate layer fluid is well predicted using plume theory. Acknowledgments: Funding for this study was provided by NSERC.

  18. Enhanced blood-brain barrier transmigration using a novel transferrin embedded fluorescent magneto-liposome nanoformulation

    NASA Astrophysics Data System (ADS)

    Ding, Hong; Sagar, Vidya; Agudelo, Marisela; Pilakka-Kanthikeel, Sudheesh; Subba Rao Atluri, Venkata; Raymond, Andrea; Samikkannu, Thangavel; Nair, Madhavan P.

    2014-02-01

    The blood-brain barrier (BBB) is considered as the primary impediment barrier for most drugs. Delivering therapeutic agents to the brain is still a big challenge to date. In our study, a dual mechanism, receptor mediation combined with external non-invasive magnetic force, was incorporated into ferrous magnet-based liposomes for BBB transmigration enhancement. The homogenous magnetic nanoparticles (MNPs), with a size of ˜10 nm, were synthesized and confirmed by TEM and XRD respectively. The classical magnetism assay showed the presence of the characteristic superparamagnetic property. These MNPs encapsulated in PEGylated fluorescent liposomes as magneto-liposomes (MLs) showed mono-dispersion, ˜130 ± 10 nm diameter, by dynamic laser scattering (DLS) using the lipid-extrusion technique. Remarkably, a magnetite encapsulation efficiency of nearly 60% was achieved. Moreover, the luminescence and hydrodynamic size of the MLs was stable for over two months at 4 ° C. Additionally, the integrity of the ML structure remained unaffected through 120 rounds of circulation mimicking human blood fluid. After biocompatibility confirmation by cytotoxicity evaluation, these fluorescent MLs were further embedded with transferrin and applied to an in vitro BBB transmigration study in the presence or absence of external magnetic force. Comparing with magnetic force- or transferrin receptor-mediated transportation alone, their synergy resulted in 50-100% increased transmigration without affecting the BBB integrity. Consequently, confocal microscopy and iron concentration in BBB-composed cells further confirmed the higher cellular uptake of ML particles due to the synergic effect. Thus, our multifunctional liposomal magnetic nanocarriers possess great potential in particle transmigration across the BBB and may have a bright future in drug delivery to the brain.

  19. Enhanced blood-brain barrier transmigration using a novel transferrin embedded fluorescent magneto-liposome nanoformulation.

    PubMed

    Ding, Hong; Sagar, Vidya; Agudelo, Marisela; Pilakka-Kanthikeel, Sudheesh; Atluri, Venkata Subba Rao; Raymond, Andrea; Samikkannu, Thangavel; Nair, Madhavan P

    2014-02-07

    The blood-brain barrier (BBB) is considered as the primary impediment barrier for most drugs. Delivering therapeutic agents to the brain is still a big challenge to date. In our study, a dual mechanism, receptor mediation combined with external non-invasive magnetic force, was incorporated into ferrous magnet-based liposomes for BBB transmigration enhancement. The homogenous magnetic nanoparticles (MNPs), with a size of ∼10 nm, were synthesized and confirmed by TEM and XRD respectively. The classical magnetism assay showed the presence of the characteristic superparamagnetic property. These MNPs encapsulated in PEGylated fluorescent liposomes as magneto-liposomes (MLs) showed mono-dispersion, ∼130 ± 10 nm diameter, by dynamic laser scattering (DLS) using the lipid-extrusion technique. Remarkably, a magnetite encapsulation efficiency of nearly 60% was achieved. Moreover, the luminescence and hydrodynamic size of the MLs was stable for over two months at 4 ° C. Additionally, the integrity of the ML structure remained unaffected through 120 rounds of circulation mimicking human blood fluid. After biocompatibility confirmation by cytotoxicity evaluation, these fluorescent MLs were further embedded with transferrin and applied to an in vitro BBB transmigration study in the presence or absence of external magnetic force. Comparing with magnetic force- or transferrin receptor-mediated transportation alone, their synergy resulted in 50-100% increased transmigration without affecting the BBB integrity. Consequently, confocal microscopy and iron concentration in BBB-composed cells further confirmed the higher cellular uptake of ML particles due to the synergic effect. Thus, our multifunctional liposomal magnetic nanocarriers possess great potential in particle transmigration across the BBB and may have a bright future in drug delivery to the brain.

  20. DIRECTIONAL FLUID TRANSPORT ACROSS ORGAN-BLOOD BARRIERS: PHYSIOLOGY AND CELL BIOLOGY

    PubMed Central

    Caceres, Paulo S.; Benedicto, Ignacio; Lehmann, Guillermo L.; Rodriguez-Boulan, Enrique J.

    2018-01-01

    Directional fluid flow is an essential process for embryo development as well as for organ and organism homeostasis. Here, we review the diverse structure of various organ-blood barriers, the driving forces, transporters and polarity mechanisms that regulate fluid transport across them, focusing on kidney-, eye- and brain-blood barriers. We end by discussing how cross-talk between barrier epithelial and endothelial cells, perivascular cells and basement membrane signaling contribute to generate and maintain organ-blood barriers. PMID:28003183

  1. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  2. Restrictive Versus Massive Fluid Resuscitation Strategy (REFILL study), influence on blood loss and hemostatic parameters in obstetric hemorrhage: study protocol for a randomized controlled trial.

    PubMed

    de Lange, Natascha; Schol, Pim; Lancé, Marcus; Woiski, Mallory; Langenveld, Josje; Rijnders, Robbert; Smits, Luc; Wassen, Martine; Henskens, Yvonne; Scheepers, Hubertina

    2018-03-06

    Postpartum hemorrhage (PPH) is associated with maternal morbidity and mortality and has an increasing incidence in high-resource countries, despite dissemination of guidelines, introduction of skills training, and correction for risk factors. Current guidelines advise the administration, as fluid resuscitation, of almost twice the amount of blood lost. This advice is not evidence-based and could potentially harm patients. All women attending the outpatient clinic who are eligible will be informed of the study; oral and written informed consent will be obtained. Where there is more than 500 ml blood loss and ongoing bleeding, patients will be randomized to care as usual, fluid resuscitation with 1.5-2 times the amount of blood loss or fluid resuscitation with 0.75-1.0 times the blood loss. Blood loss will be assessed by weighing all draping. A blood sample, for determining hemoglobin concentration, hematocrit, thrombocyte concentration, and conventional coagulation parameters will be taken at the start of the study, after 60 min, and 12-18 h after delivery. In a subgroup of women, additional thromboelastometric parameters will be obtained. Our hypothesis is that massive fluid administration might lead to a progression of bleeding due to secondary coagulation disorders. In non-pregnant individuals with massive blood loss, restrictive fluid management has been shown to prevent a progression to dilution coagulopathy. These data, however, cannot be extrapolated to women in labor. Our objective is to compare both resuscitation protocols in women with early, mild PPH (blood loss 500-750 ml) and ongoing bleeding, taking as primary outcome measure the progression to severe PPH (blood loss > 1000 ml). Netherlands Trial Register, NTR 3789 . Registered on 11 January 2013.

  3. Dense Deposit Disease Mimicking a Renal Small Vessel Vasculitis

    PubMed Central

    Singh, Lavleen; Bhardwaj, Swati; Sinha, Aditi; Bagga, Arvind; Dinda, Amit

    2016-01-01

    Dense deposit disease is caused by fluid-phase dysregulation of the alternative complement pathway and frequently deviates from the classic membranoproliferative pattern of injury on light microscopy. Other patterns of injury described for dense deposit disease include mesangioproliferative, acute proliferative/exudative, and crescentic GN. Regardless of the histologic pattern, C3 glomerulopathy, which includes dense deposit disease and C3 GN, is defined by immunofluorescence intensity of C3c two or more orders of magnitude greater than any other immune reactant (on a 0–3 scale). Ultrastructural appearances distinguish dense deposit disease and C3 GN. Focal and segmental necrotizing glomerular lesions with crescents, mimicking a small vessel vasculitis such as ANCA-associated GN, are a very rare manifestation of dense deposit disease. We describe our experience with this unusual histologic presentation and distinct clinical course of dense deposit disease, discuss the pitfalls in diagnosis, examine differential diagnoses, and review the relevant literature. PMID:26361799

  4. Subarachnoid Hemorrhage due to Spinal Cord Schwannoma Presenting Findings Mimicking Meningitis.

    PubMed

    Zhang, Hong-Mei; Zhang, Yin-Xi; Zhang, Qing; Song, Shui-Jiang; Liu, Zhi-Rong

    2016-08-01

    Subarachnoid hemorrhage (SAH) of spinal origin is uncommon in clinical practice, and spinal schwannomas associated with SAH are even more rarely reported. We report an unusual case of spinal SAH mimicking meningitis with normal brain computed tomography (CT)/magnetic resonance imaging (MRI) and negative CT angiography. Cerebrospinal fluid examination results were consistent with the manifestation of SAH. Spinal MRI performed subsequently showed an intradural extramedullary mass. The patient received surgery and was finally diagnosed with spinal cord schwannoma. A retrospective chart review of the patient was performed. We describe a case of SAH due to spinal cord schwannoma. Our case highlights the importance of careful history taking and complete evaluation. We emphasize that spinal causes should always be ruled out in patients with angionegative SAH and that schwannoma should be considered in the differential diagnosis of SAH etiologies even though rare. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.

  5. [Primary central nervous system lymphoma mimicking ventriculitis].

    PubMed

    Yamamoto, Shiro; Nagano, Seiji; Shibata, Sumiya; Kunieda, Takeharu; Imai, Yukihiro; Kohara, Nobuo

    2013-01-01

    A 66-year-old man presented with deteriorated bradykinesia, gait disturbance, disorientation, and urinary incontinence for three weeks. Magnetic resonance imaging (MRI) showed dilatation of the ventricles. Cerebrospinal fluid (CSF) examination demonstrated lymphocytic pleocytosis, elevation of protein levels, and decreased of glucose levels. A gadolinium-enhanced MRI revealed lesions in the ventricular wall and choroid plexus, mimicking ventriculitis. No evidence of bacterial, fungal, mycobacterial, or viral infections were observed in the CSF. Flow cytometry of CSF showed predominance of CD20+, λ+ cells. PCR examination of CSF revealed positive IgH gene rearrangement, suggesting B cell lymphoma. Endoscopic brain biopsy showed diffuse large B cell lymphoma. As the patient had no evidence of lymphoma in the other organs, we made a diagnosed of primary central nervous system lymphoma (PCNSL). A limited intraventricular spread of PCNSL is rare but important as one of differential diagnosis of ventriculitis.

  6. OpenFOAM: Open source CFD in research and industry

    NASA Astrophysics Data System (ADS)

    Jasak, Hrvoje

    2009-12-01

    The current focus of development in industrial Computational Fluid Dynamics (CFD) is integration of CFD into Computer-Aided product development, geometrical optimisation, robust design and similar. On the other hand, in CFD research aims to extend the boundaries ofpractical engineering use in "non-traditional " areas. Requirements of computational flexibility and code integration are contradictory: a change of coding paradigm, with object orientation, library components, equation mimicking is proposed as a way forward. This paper describes OpenFOAM, a C++ object oriented library for Computational Continuum Mechanics (CCM) developed by the author. Efficient and flexible implementation of complex physical models is achieved by mimicking the form ofpartial differential equation in software, with code functionality provided in library form. Open Source deployment and development model allows the user to achieve desired versatility in physical modeling without the sacrifice of complex geometry support and execution efficiency.

  7. Anti-diabetic activity of fused PPARγ-SIRT1 ligands with limited body-weight gain by mimicking calorie restriction and decreasing SGK1 expression.

    PubMed

    Pirat, Celine; Dacquet, Catherine; Leclerc, Veronique; Hennuyer, Nathalie; Beucher-Gaudin, Monique; Zanirato, Ghislaine; Géant, Anne; Staels, Bart; Ktorza, Alain; Farce, Amaury; Caignard, Daniel-Henri; Berthelot, Pascal; Lebegue, Nicolas

    2017-09-08

    A series of benzothiazol-2-one containing α-ethoxyphenylpropionic acid derivatives incorporating resveratrol or butein scaffolds were designed as fused full PPARγ agonist ligands and SIRT1-activating compounds for the treatment of type 2 diabetes (T2D) and its complications. Compound 14d displayed the best in vitro pharmacological profile with full PPARγ agonist activity (Emax = 98%, EC 50  = 200 nM), SIRT1 enzymatic activation (+128%) and SGK1 expression inhibition (- 57%) which is known to limit side effects as fluid retention and body-weight gain. Compound 14d showed high efficacy in an ob/ob mice model with significant decreases in serum triglyceride, glucose and insulin levels but mostly with limited body-weight gain by mimicking calorie restriction (CR) and inhibiting SGK1 expression. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Dipteran larvae and microbes facilitate nutrient sequestration in the Nepenthes gracilis pitcher plant host.

    PubMed

    Lam, Weng Ngai; Chong, Kwek Yan; Anand, Ganesh S; Tan, Hugh Tiang Wah

    2017-03-01

    The fluid-containing traps of Nepenthes carnivorous pitcher plants (Nepenthaceae) are often inhabited by organisms known as inquilines. Dipteran larvae are key components of such communities and are thought to facilitate pitcher nitrogen sequestration by converting prey protein into inorganic nitrogen, although this has never been demonstrated in Nepenthes Pitcher fluids are also inhabited by microbes, although the relationship(s) between these and the plant is still unclear. In this study, we examined the hypothesis of digestive mutualism between N. gracilis pitchers and both dipteran larvae and fluid microbes. Using dipteran larvae, prey and fluid volumes mimicking in situ pitcher conditions, we conducted in vitro experiments and measured changes in available fluid nitrogen in response to dipteran larvae and microbe presence. We showed that the presence of dipteran larvae resulted in significantly higher and faster releases of ammonium and soluble protein into fluids in artificial pitchers, and that the presence of fluid microbes did likewise for ammonium. We showed also that niche segregation occurs between phorid and culicid larvae, with the former fragmenting prey carcasses and the latter suppressing fluid microbe levels. These results clarify the relationships between several key pitcher-dwelling organisms, and show that pitcher communities facilitate nutrient sequestration in their host. © 2017 The Author(s).

  9. Coherent structures over Super Hydrophobic and Liquid Infused Surfaces

    NASA Astrophysics Data System (ADS)

    Arenas, Isnardo; Bernardini, Matteo; Leonardi, Stefano

    2017-11-01

    Numerical Simulations of two superposed fluids in a turbulent channel have been performed. Both walls of the channel are made of longitudinal riblets with a gas fractions of 0.5 and several pitch values p+ = 18 , 36 , 72 , 144 . For Liquid Infused Surfaces, LIS, with a viscosity ratio m =μ1 /μ2 = 0.4 (where the subscripts 1 and 2 indicate the fluid in the cavities and the overlying fluid respectively) two cases have been considered varying the Weber number: We = 0 , implying an interface sustained by the surface tension and We = 1000 with the dynamics of the interface between the two fluids modeled with a Level Set Approach. Results are compared to the case mimicking water over air (Super hydrophobic Surface SHS m = 0.02) and We = 0 . A smooth channel with one fluid only at Reτ = 180 is used as reference and to assess how the LIS and SHS modify coherent structures near the wall. Numerical simulations were performed on XSEDE TACC under Grant CTS070066. This work was supported by ONR MURI Grants N00014-12-01-0875 and N00014-12-01-0962.

  10. Influence of Spatial Resolution in Three-dimensional Cine Phase Contrast Magnetic Resonance Imaging on the Accuracy of Hemodynamic Analysis

    PubMed Central

    Fukuyama, Atsushi; Isoda, Haruo; Morita, Kento; Mori, Marika; Watanabe, Tomoya; Ishiguro, Kenta; Komori, Yoshiaki; Kosugi, Takafumi

    2017-01-01

    Introduction: We aim to elucidate the effect of spatial resolution of three-dimensional cine phase contrast magnetic resonance (3D cine PC MR) imaging on the accuracy of the blood flow analysis, and examine the optimal setting for spatial resolution using flow phantoms. Materials and Methods: The flow phantom has five types of acrylic pipes that represent human blood vessels (inner diameters: 15, 12, 9, 6, and 3 mm). The pipes were fixed with 1% agarose containing 0.025 mol/L gadolinium contrast agent. A blood-mimicking fluid with human blood property values was circulated through the pipes at a steady flow. Magnetic resonance (MR) images (three-directional phase images with speed information and magnitude images for information of shape) were acquired using the 3-Tesla MR system and receiving coil. Temporal changes in spatially-averaged velocity and maximum velocity were calculated using hemodynamic analysis software. We calculated the error rates of the flow velocities based on the volume flow rates measured with a flowmeter and examined measurement accuracy. Results: When the acrylic pipe was the size of the thoracicoabdominal or cervical artery and the ratio of pixel size for the pipe was set at 30% or lower, spatially-averaged velocity measurements were highly accurate. When the pixel size ratio was set at 10% or lower, maximum velocity could be measured with high accuracy. It was difficult to accurately measure maximum velocity of the 3-mm pipe, which was the size of an intracranial major artery, but the error for spatially-averaged velocity was 20% or less. Conclusions: Flow velocity measurement accuracy of 3D cine PC MR imaging for pipes with inner sizes equivalent to vessels in the cervical and thoracicoabdominal arteries is good. The flow velocity accuracy for the pipe with a 3-mm-diameter that is equivalent to major intracranial arteries is poor for maximum velocity, but it is relatively good for spatially-averaged velocity. PMID:28132996

  11. Efficiency of International Classification of Diseases, Ninth Revision, Billing Code Searches to Identify Emergency Department Visits for Blood or Body Fluid Exposures through a Statewide Multicenter Database

    PubMed Central

    Rosen, Lisa M.; Liu, Tao; Merchant, Roland C.

    2016-01-01

    BACKGROUND Blood and body fluid exposures are frequently evaluated in emergency departments (EDs). However, efficient and effective methods for estimating their incidence are not yet established. OBJECTIVE Evaluate the efficiency and accuracy of estimating statewide ED visits for blood or body fluid exposures using International Classification of Diseases, Ninth Revision (ICD-9), code searches. DESIGN Secondary analysis of a database of ED visits for blood or body fluid exposure. SETTING EDs of 11 civilian hospitals throughout Rhode Island from January 1, 1995, through June 30, 2001. PATIENTS Patients presenting to the ED for possible blood or body fluid exposure were included, as determined by prespecified ICD-9 codes. METHODS Positive predictive values (PPVs) were estimated to determine the ability of 10 ICD-9 codes to distinguish ED visits for blood or body fluid exposure from ED visits that were not for blood or body fluid exposure. Recursive partitioning was used to identify an optimal subset of ICD-9 codes for this purpose. Random-effects logistic regression modeling was used to examine variations in ICD-9 coding practices and styles across hospitals. Cluster analysis was used to assess whether the choice of ICD-9 codes was similar across hospitals. RESULTS The PPV for the original 10 ICD-9 codes was 74.4% (95% confidence interval [CI], 73.2%–75.7%), whereas the recursive partitioning analysis identified a subset of 5 ICD-9 codes with a PPV of 89.9% (95% CI, 88.9%–90.8%) and a misclassification rate of 10.1%. The ability, efficiency, and use of the ICD-9 codes to distinguish types of ED visits varied across hospitals. CONCLUSIONS Although an accurate subset of ICD-9 codes could be identified, variations across hospitals related to hospital coding style, efficiency, and accuracy greatly affected estimates of the number of ED visits for blood or body fluid exposure. PMID:22561713

  12. Study of blood flow in several benchmark micro-channels using a two-fluid approach

    PubMed Central

    Wu, Wei-Tao; Yang, Fang; Antaki, James F.; Aubry, Nadine; Massoudi, Mehrdad

    2015-01-01

    It is known that in a vessel whose characteristic dimension (e.g., its diameter) is in the range of 20 to 500 microns, blood behaves as a non-Newtonian fluid, exhibiting complex phenomena, such as shear-thinning, stress relaxation, and also multi-component behaviors, such as the Fahraeus effect, plasma-skimming, etc. For describing these non-Newtonian and multi-component characteristics of blood, using the framework of mixture theory, a two-fluid model is applied, where the plasma is treated as a Newtonian fluid and the red blood cells (RBCs) are treated as shear-thinning fluid. A computational fluid dynamic (CFD) simulation incorporating the constitutive model was implemented using OpenFOAM® in which benchmark problems including a sudden expansion and various driven slots and crevices were studied numerically. The numerical results exhibited good agreement with the experimental observations with respect to both the velocity field and the volume fraction distribution of RBCs. PMID:26240438

  13. Numerical simulation of the non-Newtonian blood flow through a mechanical aortic valve. Non-Newtonian blood flow in the aortic root

    NASA Astrophysics Data System (ADS)

    De Vita, F.; de Tullio, M. D.; Verzicco, R.

    2016-04-01

    This work focuses on the comparison between Newtonian and non-Newtonian blood flows through a bileaflet mechanical heart valve in the aortic root. The blood, in fact, is a concentrated suspension of cells, mainly red blood cells, in a Newtonian matrix, the plasma, and consequently its overall behavior is that of a non-Newtonian fluid owing to the action of the cells' membrane on the fluid part. The common practice, however, assumes the blood in large vessels as a Newtonian fluid since the shear rate is generally high and the effective viscosity becomes independent of the former. In this paper, we show that this is not always the case even in the aorta, the largest artery of the systemic circulation, owing to the pulsatile and transitional nature of the flow. Unexpectedly, for most of the pulsating cycle and in a large part of the fluid volume, the shear rate is smaller than the threshold level for the blood to display a constant effective viscosity and its shear thinning character might affect the system dynamics. A direct inspection of the various flow features has shown that the valve dynamics, the transvalvular pressure drop and the large-scale features of the flow are very similar for the Newtonian and non-Newtonian fluid models. On the other hand, the mechanical damage of the red blood cells (hemolysis), induced by the altered stress values in the flow, is larger for the non-Newtonian fluid model than for the Newtonian one.

  14. Prenatal diagnosis of congenital toxoplasmosis: comparative value of fetal blood and amniotic fluid using serological techniques and cultures.

    PubMed

    Fricker-Hidalgo, H; Pelloux, H; Muet, F; Racinet, C; Bost, M; Goullier-Fleuret, A; Ambroise-Thomas, P

    1997-09-01

    The prenatal diagnosis of congenital toxoplasmosis is mainly based on biological tests performed on fetal blood and amniotic fluid. We studied the performance of neonatal diagnosis procedures and the results of fetal blood and amniotic fluid analysis. Of 127 women who contracted toxoplasmosis and underwent prenatal diagnosis, the postnatal serological follow-up was long enough to definitively diagnose congenital toxoplasmosis in 19 cases and to exclude it in 27 cases. Prenatal diagnosis allowed the detection of 94.7 per cent (18/19) of the infected fetuses. The sensitivities of tests in amniotic fluid and fetal blood were equivalent, 88.2 per cent (15/17) and 87.5 per cent (14/16), respectively. In fetal blood, biological techniques were positive in 12/16 cases and in 2/16 cases, serological tests were the only positive sign. The specificities of tests in amniotic fluid and fetal blood were respectively 100 per cent (23/23) and 86.3 per cent (19/22) (three false-positive serological results). These results, added to the lower morbidity of amniocentesis compared with cordocentesis, might lead to cordocentesis being abandoned in the prenatal diagnosis of congenital toxoplasmosis.

  15. A blood-testis barrier restricting passage from blood into rete testis fluid but not into lymph

    PubMed Central

    Setchell, B. P.; Voglmayr, J. K.; Waites, G. M. H.

    1969-01-01

    1. A permeability barrier in or around the seminiferous tubules of rams has been demonstrated by studying the rate of passage of a variety of substances from blood plasma into fluid collected from the rete testis and into testicular lymph. 2. All substances studied passed readily into testicular lymph. 3. Tritiated water, urea, ethanol and bicarbonate in rete testis fluid equilibrated with blood plasma within 3 hr; Na+, K+, Rb+, Cl-, I-, CNS-, creatinine and galactose entered slowly and p-aminohippurate (PAH), glutamate, iodinated albumin, inulin and [51Cr]EDTA did not appear in rete testis fluid at all. 4. Rubidium was excluded relative to iodoantipyrine from the testes of control and hypophysectomized rats and from rat testes heated to 37, 40, 43 and 45° C; no such exclusion was seen in testes of rats which had been given cadmium chloride 5 months earlier so as to destroy the seminiferous tubules. 5. It is suggested that this permeability barrier will regulate the access to the seminiferous epithelium of some constituents of blood plasma, isolate the germinal cells immunologically and help to maintain the concentration differences between rete testis fluid and lymph or blood plasma. PMID:4973530

  16. Sleeping sickness

    MedlinePlus

    ... to confirm the diagnosis. Tests include the following: Blood smear to check for parasites Cerebrospinal fluid tests (fluid from your spinal cord) Complete blood count (CBC) Lymph node aspiration Treatment Medicines used ...

  17. Comparative evaluation of serum, FTA filter-dried blood and oral fluid as sample material for PRRSV diagnostics by RT-qPCR in a small-scale experimental study.

    PubMed

    Steinrigl, Adolf; Revilla-Fernández, Sandra; Wodak, Eveline; Schmoll, Friedrich; Sattler, Tatjana

    2014-01-01

    Recently, research into alternative sample materials, such as oral fluid or filter-dried blood has been intensified, in order to facilitate cost-effective and animal-friendly sampling of individuals or groups of pigs for diagnostic purposes. The objective of this study was to compare the sensitivity of porcine reproductive and respiratory syndrome virus (PRRSV)-RNA detection by reverse transcription quantitative real-time PCR (RT-qPCR) in serum, FTA filter-dried blood and oral fluid sampled from individual pigs. Ten PRRSV negative pigs were injected with an EU-type PRRSV live vaccine. Blood and oral fluid samples were taken from each pig before, and 4, 7, 14 and 21 days after vaccination. All samples were then analyzed by PRRSV RT-qPCR. In serum, eight often pigs tested RT-qPCR positive at different time points post infection. Absolute quantification showed low serum PRRSV-RNA loads in most samples. In comparison to serum, sensitivity of PRRSV-RNA detection was strongly reduced in matched FTA filter-dried blood and in oral fluid from the same pigs. These results indicate that with low PRRSV-RNA loads the diagnostic sensitivity of PRRSV-RNA detection by RT-qPCR achieved with serum is currently unmatched by either FTA filter-dried blood or oral fluid.

  18. Torsemide

    MedlinePlus

    ... high blood pressure. Torsemide is used to treat edema (fluid retention; excess fluid held in body tissues) ... your doctor.Torsemide controls high blood pressure and edema but does not cure these conditions. Continue to ...

  19. A comprehensive Guyton model analysis of physiologic responses to preadapting the blood volume as a countermeasure to fluid shifts

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Srinivasan, R. S.; Myrick, E. E.; Blomkalns, A. L.; Charles, J. B.

    1994-01-01

    The Guyton model of fluid, electrolyte, and circulatory regulation is an extensive mathematical model capable of simulating a variety of experimental conditions. It has been modified for use at NASA to simulate head-down tilt, a frequently used analog of weightlessness. Weightlessness causes a headward shift of body fluids that is believed to expand central blood volume, triggering a series of physiologic responses resulting in large losses of body fluids. We used the modified Guyton model to test the hypothesis that preadaptation of the blood volume before weightless exposure could counteract the central volume expansion caused by fluid shifts, and thereby attenuate the circulatory and renal responses that result in body fluid losses. Simulation results show that circulatory preadaptation, by a procedure resembling blood donation immediately before head-down bedrest, is effective in damping the physiologic responses to fluid shifts and reducing body fluid losses. After 10 hours of head-down tilt, preadaptation also produces higher blood volume, extracellular volume, and total body water for 20 to 30 days of bedrest, compared with non-preadapted control. These results indicate that circulatory preadaptation before current Space Shuttle missions may be beneficial for the maintenance of reentry and postflight orthostatic tolerance in astronauts. This paper presents a comprehensive examination of the simulation results pertaining to changes in relevant physiologic variables produced by blood volume reduction before a prolonged head-down tilt. The objectives were to study and develop the countermeasure theoretically, to aid in planning experimental studies of the countermeasure, and to identify potentially disadvantageous physiologic responses that may be caused by the countermeasure.

  20. Characterization of long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate beads in vitro by two distinct sample collection methods.

    PubMed

    Tulipan, Rachel J; Phillips, Heidi; Garrett, Laura D; Dirikolu, Levent; Mitchell, Mark A

    2017-05-01

    OBJECTIVE To characterize long-term elution of platinum from carboplatin-impregnated calcium sulfate hemihydrate (CI-CSH) beads in vitro by comparing 2 distinct sample collection methods designed to mimic 2 in vivo environments. SAMPLES 162 CI-CSH beads containing 4.6 mg of carboplatin (2.4 mg of platinum/bead). PROCEDURES For method 1, which mimicked an in vivo environment with rapid and complete fluid exchange, each of 3 plastic 10-mL conical tubes contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained by evacuation of all fluid at 1, 2, 3, 6, 9, and 12 hours and 1, 2, 3, 6, 9, 12, 15, 18, 22, 26, and 30 days. Five milliliters of fresh PBS solution was then added to each tube. For method 2, which mimicked an in vivo environment with no fluid exchange, each of 51 tubes (ie, 3 tubes/17 sample collection times) contained 3 CI-CSH beads and 5 mL of PBS solution. Eluent samples were obtained from the assigned tubes for each time point. All samples were analyzed for platinum content by inductively coupled plasma-mass spectrometry. RESULTS Platinum was released from CI-CSH beads for 22 to 30 days. Significant differences were found in platinum concentration and percentage of platinum eluted from CI-CSH beads over time for each method. Platinum concentrations and elution percentages in method 2 samples were significantly higher than those of method 1 samples, except for the first hour measurements. CONCLUSIONS AND CLINICAL RELEVANCE Sample collection methods 1 and 2 may provide estimates of the minimum and maximum platinum release, respectively, from CI-CSH beads in vivo.

  1. Amylase, lipase, and volume of drainage fluid in gastrectomy for the early detection of complications caused by pancreatic leakage.

    PubMed

    Seo, Kyung Won; Yoon, Ki Young; Lee, Sang Ho; Shin, Yeon Myung; Choi, Kyung Hyun; Hwang, Hyun Yong

    2011-12-01

    Pancreatic leakage is a serious complication of gastrectomy due to stomach cancer. Therefore, we analyzed amylase and lipase concentrations in blood and drainage fluid, and evaluated the volume of drainage fluid to discern their usefulness as markers for the early detection of serious pancreatic leakage requiring reoperation after gastrectomy. From January 2001 to December 2007, we retrospectively analyzed data from 24,072 patient samples. We divided patients into two groups; 1) complications with pancreatic leakage (CG), and 2) no complications associated with pancreatic leakage (NCG). Values of amylase and lipase in the blood and drainage fluid, volume of the drainage fluid, and relationships among the volumes, amylase values, and lipase values in the drainage fluid were evaluated, respectively in the two groups. The mean amylase values of CG were significantly higher than those of NCG in blood and drainage fluid (P < 0.05). For lipase, statistically significant differences were observed in drainage fluid (P < 0.05). The mean volume (standard deviation) of the drained fluid through the tube between CG (n = 22) and NCG (n = 236) on postoperative day 1 were 368.41 (266.25) and 299.26 (300.28), respectively. There were no statistically significant differences between the groups (P = 0.298). There was a correlation between the amylase and lipase values in the drainage fluid (r = 0.812, P = 0.000). Among postoperative amylase and lipase values in blood and drainage fluid, and the volume of drainage fluid, the amylase in drainage fluid was better differentiated between CG and NCG than other markers. The volume of the drainage fluid did not differ significantly between groups.

  2. Recent Progress of Microfluidics in Translational Applications

    PubMed Central

    Liu, Zongbin; Han, Xin

    2016-01-01

    Microfluidics, featuring microfabricated structures, is a technology for manipulating fluids at the micrometer scale. The small dimension and flexibility of microfluidic systems are ideal for mimicking molecular and cellular microenvironment, and show great potential in translational research and development. Here, the recent progress of microfluidics in biological and biomedical applications, including molecular analysis, cellular analysis, and chip-based material delivery and biomimetic design is presented. The potential future developments in the translational microfluidics field are also discussed. PMID:27091777

  3. Early onset primary pulmonary cryptococcosis in a renal transplant patient.

    PubMed

    Tarai, B; Kher, V; Kotru, P; Sabhikhi, A; Barman, P; Rattan, A

    2010-01-01

    We report a case of primary pulmonary cryptococcosis in a post-renal transplant patient. A 65-year-old male renal transplant patient was admitted to the hospital with a low grade fever of 1 month, radiologically mimicking tuberculosis (TB). Broncho-alveolar fluid (BAL) shows capsulated yeast, and Cryptococcus neoformans was grown on culture supported by cytology and histopathological examination. Cryptococcal antigen was positive (32-fold) in serum and was negative in cerebrospinal fluid (CSF). The patient was given amphotericin B and 5-flucytosine and clinical improvement was seen on a weekly follow up. The serum cryptococcal antigen test might contribute to the early detection and treatment of pulmonary cryptococcosis. The results of antifungal susceptibility were aid in selecting the drug of choice for treatment.

  4. Triamterene and Hydrochlorothiazide

    MedlinePlus

    ... is used to treat high blood pressure and edema (fluid retention; excess fluid held in body tissues) ... doctor.This medication controls high blood pressure and edema but does not cure these conditions. Continue to ...

  5. IgA Nephropathy

    MedlinePlus

    ... the tiny working units of the kidneys that filter wastes and remove extra fluid from the blood. ... the tiny working units of the kidneys that filter wastes and remove extra fluid from the blood. ...

  6. Influences of red blood cell and platelet counts on the distribution and elimination of crystalloid fluid.

    PubMed

    Hahn, Robert G

    2017-01-01

    A high number of blood cells increases the viscosity of the blood. The present study explored whether variations in blood cell counts are relevant to the distribution and elimination of infused crystalloid fluid. On three different occasions, 10 healthy male volunteers received an intravenous infusion of 25mL/kg of Ringer's acetate, Ringer's lactate, and isotonic saline over 30min. Blood hemoglobin and urinary excretion were monitored for 4h and used as input in a two-volume kinetic model, using nonlinear mixed effects software. The covariates used in the kinetic model were red blood cell and platelet counts, the total leukocyte count, the use of isotonic saline, and the arterial pressure. Red blood cell and platelet counts in the upper end of the normal range were associated with a decreased rate of distribution and redistribution of crystalloid fluid. Simulations showed that high counts were correlated with volume expansion of the peripheral (interstitial) fluid space, while the plasma volume was less affected. In contrast, the total leukocyte count had no influence on the distribution, redistribution, or elimination. The use of isotonic saline caused a transient reduction in the systolic arterial pressure (P<0.05) and doubled the half-life of infused fluid in the body when compared to the two Ringer solutions. Isotonic saline did not decrease the serum potassium concentration, despite the fact that saline is potassium-free. High red blood cell and platelet counts are associated with peripheral accumulation of infused crystalloid fluid. Copyright © 2017 The Lithuanian University of Health Sciences. Production and hosting by Elsevier Sp. z o.o. All rights reserved.

  7. Increased Activity and Apoptosis of Eosinophils in Blister Fluids, Skin and Peripheral Blood of Patients with Bullous Pemphigoid.

    PubMed

    Engmann, Judith; Rüdrich, Urda; Behrens, Georg; Papakonstantinou, Eleni; Gehring, Manuela; Kapp, Alexander; Raap, Ulrike

    2017-04-06

    Bullous pemphigoid (BP) is an autoimmune blistering skin disease that is more common in elderly individuals. The aim of this study was to determine the functional activity of eosinophils in patients with BP compared with healthy donors. Blood, skin and blister-derived eosinophils were strongly activated in patients with BP, seen by increased surface expression of CD69 compared with controls. CD11b was also increased in BP blood eosinophils, which may explain the striking accumulation of eosinophils in BP (1×106 per ml blister fluid). Furthermore, CCL26 was expressed by activated eosinophils in BP skin and in blister fluid. BP eosinophils also released IL-6, IL-8 and IL-1α in BP blister fluids. Apoptosis in cultivated BP eosinophils was increased and accompanied by enhanced surface externalization of CD95. Caspase 3 positive eosinophils in lesional BP skin and blister fluid also showed the initiation of apoptosis. These results reveal novel pathophysiological aspects of BP, with a strong activation pattern and increased apoptosis of eosinophils in the peripheral blood, skin and blister fluids.

  8. Filarial pleural effusion without peripheral blood or pleural fluid eosinophilia.

    PubMed

    Shukla, Amitabh Das; Chaudhary, Abhinav; Verma, Arvind Kumar; Anantha, Shreenivasa

    2017-09-19

    Lymphatic filariasis is a tropical parasitic disease and is endemic in India. It is present in various forms but its manifestation as pleural effusion is rare. Here, we describe a case of 58-year-old male who presented with complaint of left side chest pain and breathlessness. He was investigated and diagnosed as a case of left side pleural effusion due to filariasis, with peripheral blood lymphocytosis but without peripheral blood or pleural fluid eosinophilia. Our case foregrounds that filariasis can present with peripheral blood lymphocytosis and without peripheral blood or pleural fluid eosinophilia. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Numerical simulation of heat transfer in power law fluid flow through a stenosed artery

    NASA Astrophysics Data System (ADS)

    Talib, Amira Husni; Abdullah, Ilyani

    2017-11-01

    A numerical study of heat transfer in a power law fluid is investigated in this paper. The blood flow is treated as power law fluid with a presence of cosine shaped stenosis. This study reveals the effect of stenosis on the heat transfer and velocity of blood flowing in the constricted artery. The governing and energy equations are formulated in a cylindrical coordinate system. Hence, the set of equations and boundary conditions are solved numerically by Marker and Cell (MAC) method. The graphical result shows the profile of blood temperature is increased while the blood velocity is decreased at the critical height of stenosis.

  10. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation

    PubMed Central

    Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid. PMID:27513941

  11. The Etiology, Incidence, and Impact of Preservation Fluid Contamination during Liver Transplantation.

    PubMed

    Oriol, Isabel; Lladó, Laura; Vila, Marina; Baliellas, Carme; Tubau, Fe; Sabé, Núria; Fabregat, Joan; Carratalà, Jordi

    2016-01-01

    The role of contaminated preservation fluid in the development of infection after liver transplantation has not been fully elucidated. To assess the incidence and etiology of contaminated preservation fluid and determine its impact on the subsequent development of infection after liver transplantation, we prospectively studied 50 consecutive liver transplants, and cultured the following samples in each instance: preservation fluid (immediately before and at the end of the back-table procedure, and just before implantation), blood, and bile from the donor, and ascitic fluid from the recipient. When any culture was positive, blood cultures were obtained and targeted antimicrobial therapy was started. We found that the incidence of contaminated preservation fluid was 92% (46 of 50 cases of liver transplantation per year), but only 28% (14/50) were contaminated by recognized pathogens. Blood and bile cultures from the donor were positive in 28% and 6% respectively, whereas ascitic fluid was positive in 22%. The most frequently isolated microorganisms were coagulase-negative staphylococci. In nine cases, the microorganisms isolated from the preservation fluid concurred with those grown from the donor blood cultures, and in one case, the isolate matched with the one obtained from bile culture. No liver transplant recipient developed an infection due to the transmission of an organism isolated from the preservation fluid. Our findings indicate that contamination of the preservation fluid is frequent in liver transplantation, and it is mainly caused by saprophytic skin flora. Transmission of infection is low, particularly among those recipients given targeted antimicrobial treatment for organisms isolated in the preservation fluid.

  12. Damage Control Resuscitation Supplemented with Vasopressin in a Severe Polytrauma Model with Traumatic Brain Injury and Uncontrolled Internal Hemorrhage.

    PubMed

    Dickson, J Michael; Wang, Xu; St John, Alexander E; Lim, Esther B; Stern, Susan A; White, Nathan J

    2018-03-14

    Traumatic brain injury (TBI) and hemorrhagic shock (HS) are the leading causes of traumatic death worldwide and particularly on the battlefield. They are especially challenging when present simultaneously (polytrauma), and clear blood pressure end points during fluid resuscitation are not well described for this situation. The goal of this study is to evaluate for any benefit of increasing blood pressure using a vasopressor on brain blood flow during initial fluid resuscitation in a swine polytrauma model. We used a swine polytrauma model with simultaneous TBI, femur fracture, and HS with uncontrolled noncompressible internal bleeding from an aortic tear injury. Five animals were assigned to each of three experimental groups (hydroxyethyl starch only [HES], HES + 0.4 U/kg vasopressin, and no fluid resuscitation [No Fluids]). Fluids were given as two 10 mL/kg boluses according to tactical field care guidelines. Primary outcomes were mean arterial blood pressure (MAP) and brain blood flow at 60 min. Secondary outcomes were blood flows in the heart, intestine, and kidney; arterial blood lactate level; and survival at 6 hr. Organ blood flow was measured using injection of colored microspheres. Five animals were tested in each of the three groups. There was a statistically significant increase in MAP with vasopressin compared with other experimental groups, but no significant increase in brain blood flow during the first 60 min of resuscitation. The vasopressin group also exhibited greater total internal hemorrhage volume and rate. There was no difference in survival at 6 hours. In this experimental swine polytrauma model, increasing blood pressure with vasopressin did not improve brain perfusion, likely due to increased internal hemorrhage. Effective hemostasis should remain the top priority for field treatment of the polytrauma casualty with TBI.

  13. Ultrasound-induced cavitation enhances the delivery and therapeutic efficacy of an oncolytic virus in an in vitro model.

    PubMed

    Bazan-Peregrino, Miriam; Arvanitis, Costas D; Rifai, Bassel; Seymour, Leonard W; Coussios, Constantin-C

    2012-01-30

    We investigated whether ultrasound-induced cavitation at 0.5 MHz could improve the extravasation and distribution of a potent breast cancer-selective oncolytic adenovirus, AdEHE2F-Luc, to tumour regions that are remote from blood vessels. We developed a novel tumour-mimicking model consisting of a gel matrix containing human breast cancer cells traversed by a fluid channel simulating a tumour blood vessel, through which the virus and microbubbles could be made to flow. Ultrasonic pressures were chosen to maximize either broadband emissions, associated with inertial cavitation, or ultraharmonic emissions, associated with stable cavitation, while varying duty cycle to keep the total acoustic energy delivered constant for comparison across exposures. None of the exposure conditions tested affected cell viability in the absence of the adenovirus. When AdEHE2F-Luc was delivered via the vessel, inertial cavitation increased transgene expression in tumour cells by up to 200 times. This increase was not observed in the absence of Coxsackie and Adenovirus Receptor cell expression, discounting sonoporation as the mechanism of action. In the presence of inertial cavitation, AdEHE2F-Luc distribution was greatly improved in the matrix surrounding the vessel, particularly in the direction of the ultrasound beam; this enabled AdEHE2F-Luc to kill up to 80% of cancer cells within the ultrasound focal volume in the gel 24 hours after delivery, compared to 0% in the absence of cavitation. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Pharmacokinetic Profile of Oral Cannabis in Humans: Blood and Oral Fluid Disposition and Relation to Pharmacodynamic Outcomes

    PubMed Central

    Vandrey, Ryan; Herrmann, Evan S.; Mitchell, John M.; Bigelow, George E.; Flegel, Ronald; LoDico, Charles; Cone, Edward J.

    2017-01-01

    Abstract Most research on cannabis pharmacokinetics has evaluated inhaled cannabis, but oral (“edible”) preparations comprise an increasing segment of the cannabis market. To assess oral cannabis pharmacokinetics and pharmacodynamics, healthy adults (N = 6 per dose) were administered cannabis brownies containing 10, 25 or 50 mg 9-tetrahydrocannabinol (THC). Whole blood and oral fluid specimens were obtained at baseline and then for 9 days post-exposure; 6 days in a residential research setting and 3 days as outpatients. Measures of subjective, cardiovascular and performance effects were obtained at baseline and for 8 h post-ingestion. The mean Cmax for THC in whole blood was 1, 3.5 and 3.3 ng/mL for the 10, 25 and 50 mg THC doses, respectively. The mean maximum concentration (Cmax) and mean time to maximum concentration (Tmax) of 11-OH-THC in whole blood were similar to THC. Cmax blood concentrations of THCCOOH were generally higher than THC and had longer Tmax values. The mean Tmax for THC in oral fluid occurred immediately following oral dose administration, and appear to reflect local topical residue rather than systemic bioavailbility. Mean Cmax oral fluid concentrations of THCCOOH were lower than THC, erratic over time and mean Tmax occurred at longer times than THC. The window of THC detection ranged from 0 to 22 h for whole blood (limit of quantitation (LOQ) = 0.5 ng/mL) and 1.9 to 22 h for oral fluid (LOQ = 1.0 ng/mL). Subjective drug and cognitive performance effects were generally dose dependent, peaked at 1.5–3 h post-administration, and lasted 6–8 h. Whole blood cannabinoid concentrations were significantly correlated with subjective drug effects. Correlations between blood cannabinoids and cognitive performance measures, and between oral fluid and all pharmacodynamic outcomes were either non-significant or not orderly by dose. Quantitative levels of cannabinoids in whole blood and oral fluid were low compared with levels observed following inhalation of cannabis. The route of administration is important for interpretation of cannabinoid toxicology. PMID:28158482

  15. Unusual Presentation of Duodenal Ulcer Presenting with Duodenal Intussusception.

    PubMed

    Lingala, Shilpa; Moore, Andrew; Kadire, Siri; Shankar, Sridhar; Das, Kanak; Howden, Colin W

    2018-01-01

    We present a unique case of duodeno-duodenal intussusception from a duodenal bulb ulcer. A 38-year-old man presented with nausea, vomiting, and abdominal pain. Computed tomography showed duodenal intussusception. Esophagogastroduodenoscopy (EGD) showed a linear gastric ulcer and a duodenal bulb ulcer with an overlying blood clot. Helicobacter pylori status was positive. Intussusception resolved spontaneously without intervention. He completed treatment for H. pylori infection, and repeat EGD showed ulcer healing. Duodenal intussusception is rarely reported; intussusception from an edematous duodenal ulcer with an overlying blood clot mimicking a mass lesion acting as lead point has never been reported to our knowledge.

  16. Demodex folliculitis mimicking acute graft-vs-host disease.

    PubMed

    Cotliar, Jonathan; Frankfurt, Olga

    2013-12-01

    Acute graft-vs-host disease (GVHD) typically requires high-dose systemic steroids as first-line treatment. Like drug eruptions, viral exanthema, and toxic erythema of chemotherapy, Demodex folliculitis is a clinical mimicker of acute GVHD and requires nonimmunosuppressive therapy. This case of Demodex folliculitis mimicking acute GVHD highlights the need for skin biopsy in patients who have undergone a stem cell transplant with eruptions on the head and neck. A 46-year-old white woman with a history of Fms-like tyrosine kinase 3 acute myeloid leukemia presented to the dermatology clinic with a 5-day history of a nonpruritic eruption on her face and neck 28 days after undergoing a double umbilical cord blood hematopoietic stem cell transplant (HSCT). Findings from the skin biopsy demonstrated a deep dermal lymphocytic infiltrate adjacent to follicular units along with an abundance of Demodex mites noted within the hair follicles consistent with Demodex folliculitis. Oral ivermectin, 12 mg, was given, and the eruption cleared within 24 hours. To our knowledge, this is only the fifth reported case of Demodex folliculitis following HSCT, but the first ever reported to be successfully treated with oral ivermectin. Demodex folliculitis should be added to the differential diagnosis of skin eruptions that arise after HSCT.

  17. Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.

    1986-01-01

    Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.

  18. Recent Progress of Microfluidics in Translational Applications.

    PubMed

    Liu, Zongbin; Han, Xin; Qin, Lidong

    2016-04-20

    Microfluidics, featuring microfabricated structures, is a technology for manipulating fluids at the micrometer scale. The small dimension and flexibility of microfluidic systems are ideal for mimicking molecular and cellular microenvironment, and show great potential in translational research and development. Here, the recent progress of microfluidics in biological and biomedical applications, including molecular analysis, cellular analysis, and chip-based material delivery and biomimetic design is presented. The potential future developments in the translational microfluidics field are also discussed. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. Computed tomography findings mimicking appendicitis as a manifestation of colorectal cancer☆

    PubMed Central

    Watchorn, Richard E.; Poder, Liina; Wang, Zhen J.; Yeh, Benjamin M.; Webb, Emily M.; Coakley, Fergus V.

    2009-01-01

    The primary computed tomography (CT) signs of appendicitis can also be seen with other inflammatory or neoplastic processes. We report on two cases in which appendiceal dilatation and peri-appendiceal fluid or stranding were the dominant imaging manifestations of colorectal carcinoma in the ascending colon. This study highlights the need to closely examine the ascending colon in patients with a suspected CT diagnosis of acute appendicitis, since these findings may be secondary to an inconspicuous colorectal carcinoma. PMID:19857802

  20. Caterpillar locomotion-inspired valveless pneumatic micropump using a single teardrop-shaped elastomeric membrane.

    PubMed

    So, Hongyun; Pisano, Albert P; Seo, Young Ho

    2014-07-07

    This paper presents a microfluidic pump operated by an asymmetrically deformed membrane, which was inspired by caterpillar locomotion. Almost all mechanical micropumps consist of two major components of fluid halting and fluid pushing parts, whereas the proposed caterpillar locomotion-inspired micropump has only a single, bilaterally symmetric membrane-like teardrop shape. A teardrop-shaped elastomeric membrane was asymmetrically deformed and then consecutively touched down to the bottom of the chamber in response to pneumatic pressure, thus achieving fluid pushing. Consecutive touchdown motions of the teardrop-shaped membrane mimicked the propagation of a caterpillar's hump during its locomotory gait. The initial touchdown motion of the teardrop-shaped membrane at the centroid worked as a valve that blocked the inlet channel, and then, the consecutive touchdown motions pushed fluid in the chamber toward the tail of the chamber connected to the outlet channel. The propagation of the touchdown motion of the teardrop-shaped membrane was investigated using computational analysis as well as experimental studies. This caterpillar locomotion-inspired micropump composed of only a single membrane can provide new opportunities for simple integration of microfluidic systems.

  1. In vivo effects of meloxicam and aspirin on blood, gastric mucosal, and synovial fluid prostanoid synthesis in dogs.

    PubMed

    Jones, Christopher J; Streppa, Heather K; Harmon, Barry G; Budsberg, Steven C

    2002-11-01

    To evaluate in vivo activity in dogs of meloxicam or aspirin, previously shown in vitro to be a selective cyclooxygenase-2 (COX-2) inhibitor (COX-1 sparing drug), or a nonselective COX inhibitor, respectively. 12 male dogs with unilateral osteoarthritis of the stifle joint. Each dog was treated in a crossover design with aspirin or meloxicam for 21 days. Prostaglandin E2 (PGE2) concentrations were measured at days 0 (baseline), 7, and 21 of each treatment period in lipopolysaccharide (LPS)-stimulated blood, synovial fluid collected by arthrocentesis, and endoscopic gastric mucosal biopsy specimens. Thromboxane B2 (TXB2) was evaluated in blood on days 0, 7, and 21 of each treatment period. Aspirin administration significantly suppressed PGE2 concentrations in blood, gastric mucosa, synovial fluid, and suppressed TXB2 concentration in blood at days 7 and 21. Meloxicam administration significantly suppressed PGE2 concentrations in blood and synovial fluid at days 7 and 21, but had no effect on concentrations of TXB2 in blood or PGE2 in gastric mucosa. Suppression of LPS-stimulated PGE2 concentrations in blood and synovial fluid by aspirin and meloxicam administration is consistent with activity against the COX-2 isoenzyme. Suppression of concentrations of PGE2 in the gastric mucosa and TXB2 in blood by aspirin administration is consistent with activity against COX-1. Meloxicam, in contrast, had a minimal effect on functions mediated by COX-1. Meloxicam acts in vivo in dogs as a COX-1 sparing drug on target tissues by sparing gastric PGE2 synthesis while retaining antiprostaglandin effects within inflamed joints.

  2. The method and accuracy of documentation of intraoperative fluids management in liver transplantation recipients.

    PubMed

    Liao, Hsiu-Lan; Chen, Chao-Long; Wang, Chih-Hsien; Chen, Chi-Ling; Huang, Chia-Jung; Cheng, Kwok-Wai; Wang, Chih-Chi; Concejero, Allan M; Wang, Shir-Hor; Liu, Yueh-Wei; Jawade, Kailash; Wu, Shao-Chun; Jawan, Bruno

    2011-01-01

    In liver transplantation, blood loss can be massive, requiring timely and rapid fluid resuscitation. Maintaining proper documentation of fluids during such situations can be difficult and may often lead to counting errors. We report our method of documentation of fluid management during liver transplantation. Each unit of red blood cells (125 cc) that comes from the blood bank had a serial number of 10 Arabic numbers which were verified and double-checked. Each unit was then numbered and labeled as encircled absolute numbers (e.g., 1, 2, 3). Both the encircled number and the serial number of the bag were recorded in the anesthesia chart. Each liter of crystalloids and colloids were similarly numbered and labeled in sequence for ease of calculation. At the end of the operation, the nurse anesthetist ascertains that the number of units of blood products used matched with the number of units supplied by the blood bank. The total amounts of crystalloids and colloids given during the operation was also calculated, rechecked and written in a tabulated form. Since the introduction of this method, we have detected and readily corrected 3 incidences of counting discrepancy in the total units of blood products transfused and the products supplied by the blood bank. Moreover, our records have now become transparent data that are easily retrievable for future scientific research. Our method of documentation of fluid management during liver transplantation is easy, accurate and effective.

  3. Rethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids.

    PubMed

    Neoh, Kuang Hong; Hassan, Ayon Ahmed; Chen, Anqi; Sun, Yukun; Liu, Peng; Xu, Kai-Feng; Wong, Alice S T; Han, Ray P S

    2018-01-01

    Traditionally, liquid biopsy is a blood test involving the harvesting of tumor materials from peripheral blood. Tumor cells from non-blood body fluids have always been clinically available in cytological examinations but limited for use in differential diagnosis due to the low sensitivity of conventional cytopathology. With the recent significant progress in microfluidic and downstream molecular technologies, liquid biopsies have now evolved to include harvesting tumor cells and DNA fragments in all kinds of non-blood body fluids. This expansion into general body fluids presages the notion that liquid biopsy could soon be used in competition, as well as, in complementarity with tissue biopsy. Preliminary research of fluid-harvested tumor materials to spot early-stage tumors, monitor disease progression for metastasis and recurrence, and detect chemoresistance have been reported. To reflect the propagation of tumor cells in non-blood body fluids, we introduced the term Mobile Tumor Cells (MTCs), in lieu of the widely accepted term of circulating tumor cells (CTCs) resident in the bloodstream. Our review starts with a discussion on the clinical significance of MTCs, followed by a presentation of microfluidic techniques for MTC capture and various strategies for their identification. Hopefully, the phenotypic and genomic data acquired from harvested MTCs can be used to guide and improve cancer treatment decisions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. [Correlation of IL-8 and IL-6 in prostatic fluid with serum prostate-specific antigen level in patients with benign prostatic hyperplasia complicated by prostatitis].

    PubMed

    Ren, Xingfei; Wu, Chunlei; Yu, Qinnan; Zhu, Feng; Liu, Pei; Zhang, Huiqing

    2016-01-01

    To investigate the correlation of the levels of interleukin-8 (IL-8) and IL-6 in the prostatic fluid with serum levels of serum prostate-specific antigen (PSA) in patients with benign prostatic hyperplasia (BPH) complicated by prostatitis. A series of 211 patients undergoing surgery of BPH were divided into BPH group (n=75) and BPH with prostatitis group (n=136) according to the white blood cell count in the prostatic fluid. The clinical and laboratory findings were compared between the two groups, and stepwise regression analysis was used to assess the association of IL-8 and IL-6 with serum PSA level. No significant differences were found in age, BMI, blood pressure, blood glucose, blood lipids, IPSS score, PSA-Ratio, or prostate volume between the two groups (P<0.05). The patients with prostatitis had significantly increased serum PSA and prostate fluid IL-8 and IL-6 levels compared with those without prostatitis (P<0.001). Multiple linear regression analysis showed that IL-8 and IL-6 levels and white blood cell count in the prostatic fluid were all positively correlated with serum PSA level. Prostatitis is an important risk factor for elevated serum PSA level in patients with BPH, and both IL-8 and IL-6 levels in the prostatic fluid are correlated with serum PSA level.

  5. Associations of semen quality with non-essential heavy metals in blood and seminal fluid: data from the Environment and Male Infertility (EMI) study in Lebanon.

    PubMed

    Sukhn, Carol; Awwad, Johnny; Ghantous, Akram; Zaatari, Ghazi

    2018-06-21

    Human exposure to environmental pollutants is widespread. It was suggested that exposure to non-essential heavy metals may adversely affect semen development in men. To evaluate associations between non-essential heavy metals in blood and seminal fluid and semen quality parameters in men. Male partners of heterosexual couples were included. The following elements were measured in blood and seminal fluid: lead (Pb), cadmium (Cd), arsenic (As), barium (Ba), mercury (Hg), and uranium (U) using ion-coupled plasma-mass spectrometry. The fertility clinic at the American University of Beirut Medical Center. Semen quality parameters (volume, concentration, total count, progressive motility, viability, and normal morphology). We found that participants with low-quality semen had significantly higher Cd and Ba concentrations in the seminal fluid than participants with normal-quality semen. We also observed significant associations between low sperm viability and higher blood Cd and Ba, as well as higher seminal Pb, Cd, Ba, and U. Furthermore, U concentrations in the seminal fluid were associated with increased odds ratios for below-reference progressive sperm motility and normal morphology. Environmental exposures to Pb, Cd, Ba, and U appear to adversely influence sperm development in men. In non-occupationally exposed men, measurements of heavy metals in the seminal fluid may be more predictive of below-reference sperm quality parameters than in blood.

  6. Initial fluid resuscitation following adjusted body weight dosing is associated with improved mortality in obese patients with suspected septic shock.

    PubMed

    Taylor, Stephanie Parks; Karvetski, Colleen H; Templin, Megan A; Heffner, Alan C; Taylor, Brice T

    2018-02-01

    The optimal initial fluid resuscitation strategy for obese patients with septic shock is unknown. We evaluated fluid resuscitation strategies across BMI groups. Retrospective analysis of 4157 patients in a multicenter activation pathway for treatment of septic shock between 2014 and 2016. 1293 (31.3%) patients were obese (BMI≥30). Overall, higher BMI was associated with lower mortality, however this survival advantage was eliminated in adjusted analyses. Patients with higher BMI received significantly less fluid per kilogram at 3h than did patients with lower BMI (p≤0.001). In obese patients, fluid given at 3h mimicked a dosing strategy based on actual body weight (ABW) in 780 (72.2%), adjusted body weight (AdjBW) in 95 (8.8%), and ideal body weight (IBW) in 205 (19.0%). After adjusting for condition- and treatment-related variables, dosing based on AdjBW was associated with improved mortality compared to ABW (OR 0.45; 95% CI [0.19, 1.07]) and IBW (OR 0.29; 95% CI [0.11,0.74]). Using AdjBW to calculate initial fluid resuscitation volume for obese patients with suspected shock may improve outcomes compared to other weight-based dosing strategies. The optimal fluid dosing strategy for obese patients should be a focus of future prospective research. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. A durable, non power consumptive, simple seal for rotary blood pumps.

    PubMed

    Mitamura, Y; Sekine, K; Asakawa, M; Yozu, R; Kawada, S; Okamoto, E

    2001-01-01

    One of the key technologic requirements for rotary blood pumps is the sealing of the motor shaft. A mechanical seal, a journal bearing, magnetic coupling, and magnetic suspension have been developed, but they have drawbacks such as wear, thrombus formation, and power consumption. A magnetic fluid seal was developed for an axial flow pump. A magnetic fluid seal is durable, simple, and non power consumptive. Long-term experiments and finite element modeling (FEM) analyses confirmed these advantages. The seal body was composed of a Ned-Fe magnet and two pole pieces; the seal was formed by injecting ferrofluid into the gap (50 microm) between the pole pieces and the motor shaft. To contain the ferrofluid in the seal and to minimize the possibility of ferrofluid making contact with blood, a shield with a small cavity was attached to the pole piece. While submerged in blood, the sealing pressure of the seal was measured and found to be 188 mm Hg with ferrofluid LS-40 (saturated magnetization, 24.3 kA/m) at a motor speed of 10,000 rpm and 225 mm Hg under static conditions. The magnetic fluid seals performed perfectly at a pressure of 100 mm Hg for 594 + days in a static condition, and 51, 39+, and 34+ days at a motor speed of 8,000 rpm. FEM analyses indicated a theoretical sealing pressure of 260 mm Hg. The state of the magnetic fluid in the seal in water was observed with a microscope. Neither splashing of magnetic fluid nor mixing of the magnetic fluid and water was observed. The specially designed magnetic fluid seal for keeping liquids out is useful for axial flow blood pumps. The magnetic fluid seal was incorporated into an intracardiac axial flow pump.

  8. Bacteraemia caused by Sciscionella marina in a lymphoma patient: phenotypically mimicking Nocardia.

    PubMed

    Sinha, M; Shivaprakash, M R; Chakrabarti, A; Shafiulla, M; Babu, K G; Jayshree, R S

    2013-06-01

    A 55-year-old female patient with malignant lymphoma after induction chemotherapy developed fever. Blood culture yielded an organism biochemically identified as representing Nocardia spp., but molecular identification (16S rRNA gene sequencing) later identified it as representing Sciscionella marina. This is the first report, to the best of our knowledge, of Sciscionella being isolated from a human sample.

  9. The nature of the binding between LSD and a 5-HT receptor

    PubMed Central

    Berridge, M.J.; Prince, W.T.

    1974-01-01

    1 (+)-Lysergic acid diethylamide (LSD) mimicked 5-hydroxytryptamine (5-HT) in its ability to stimulate fluid secretion, to change transepithelial and intracellular potentials as well as to increase the cyclic 3′,5′-adenosine monophosphate (cyclic AMP) concentrations of isolated salivary glands of Calliphora. 2 Unlike 5-HT, LSD disengages slowly from the receptor and fluid secretion continues despite repeated washing. 3 Both 5-HT and tryptamine prevented LSD from acting on the glands. 4 LSD bound to the receptor was slowly displaced when glands were treated with agonists (tryptamine) or antagonists (gramine). 5 The property of LSD which permits it to function as an agonist despite remaining tightly bound to the receptor is discussed as a possible basis for its profound effects within the central nervous system. PMID:4375525

  10. Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

    PubMed

    Zamir, Mair; Moore, James E; Fujioka, Hideki; Gaver, Donald P

    2010-03-01

    In the field of fluid flow within the human body, focus has been placed on the transportation of blood in the systemic circulation since the discovery of that system; but, other fluids and fluid flow phenomena pervade the body. Some of the most fascinating fluid flow phenomena within the human body involve fluids other than blood and a service other than transport--the lymphatic and pulmonary systems are two striking examples. While transport is still involved in both cases, this is not the only service which they provide and blood is not the only fluid involved. In both systems, filtration, extraction, enrichment, and in general some "treatment" of the fluid itself is the primary function. The study of the systemic circulation has also been conventionally limited to treating the system as if it were an open-loop system governed by the laws of fluid mechanics alone, independent of physiological controls and regulations. This implies that system failures can be explained fully in terms of the laws of fluid mechanics, which of course is not the case. In this paper we examine the clinical implications of these issues and of the special biofluid mechanics issues involved in the lymphatic and pulmonary systems.

  11. Red blood cell generation by three-dimensional aggregate cultivation of late erythroblasts.

    PubMed

    Lee, EunMi; Han, So Yeon; Choi, Hye Sook; Chun, Bokhwan; Hwang, Byunghee; Baek, Eun Jung

    2015-02-01

    Stem cell-derived erythroid cells hold great potential for the treatment of blood-loss anemia and for erythropoiesis research; however, cultures using conventional flat plates or bioreactors have failed to show promising results. By mimicking the in vivo bone marrow (BM) environment in which most erythroid cells are physically aggregated, we show that a three-dimensional (3D) aggregate culture system facilitates erythroid cell maturation and red blood cell (RBC) production more effectively than two-dimensional high-density cell cultivation. Late erythroblasts (polychromatic or orthochromatic erythroblasts) were differentiated from cord blood CD34(+) cells over 15 days and then allowed to form tight aggregates at a minimum density of 1×10(7) cells/mL for 2-3 days. To scale up the cell culture and to make the media supply efficient throughout the cell aggregates, several macroporous microcarriers and porous scaffolds were applied to the 3D culture system. In comparison to control culture conditions, erythroid cells in 3D aggregates were significantly more differentiated toward RBCs with significantly reduced nuclear dysplasia. When 3D culture was performed inside macroporous microcarriers, the cell culture scale was increased and cells exhibited enhanced differentiation and enucleation. Microcarriers with a pore diameter of approximately 400 μm produced more mature cells than those with a smaller pore diameter. In addition, this aggregate culture method minimized the culture space and media volume required. In conclusion, a 3D aggregate culture system can be used to generate transfusable human erythrocytes at the terminal maturation stage, mimicking the in vivo BM microenvironment. Porous structures can efficiently maximize the culture scale, enabling large-scale production of RBCs. These results enhance our understanding of the importance of physical contact among late erythroblasts for their final maturation into RBCs.

  12. Yam bean seed poisoning mimicking cyanide intoxication.

    PubMed

    Hung, Y-M; Hung, S-Y; Olson, K R; Chou, K-J; Lin, S-L; Chung, H-M; Tung, C-N; Chang, J-C

    2007-02-01

    Yam bean is a common food in southern Taiwan. However, its seeds are rarely consumed. We describe five patients of yam bean seed poisoning in Taiwan, one of them life-threatening. The five patients presented with perioral numbness, nausea and vomiting after eating a same soup made from yam bean seeds. One of them, a 54-year-old woman, had difficulty breathing and lost consciousness. Physical examination showed dilated pupils and coma with no focal neurological signs. The initial blood pressure was normal. Laboratory data showed a severe anion gap metabolic acidosis, with a serum lactate level of 185 mg/dL. An initial diagnosis of cyanide intoxication was considered and she was given sodium nitrite and sodium thiosulfate i.v. Hypotension ensued shortly afterwards and pulmonary artery catheterization showed a decreased cardiac index. Aggressive fluid and inotropic therapy were given and the patient eventually recovered. The other four patients suffered only minor gastrointestinal and neurological symptoms and received supportive treatment. Cyanide levels were negative in all five patients. Yam bean seed poisoning can cause acute metabolic acidosis and altered mental status, which could be confused with acute cyanide intoxication from a cyanogenic glycoside-containing plant. To our knowledge, this is the first outbreak of yam bean seed poisoning reported in the English published work.

  13. Postmortem Fluid and Tissue Concentrations of THC, 11-OH-THC and THC-COOH.

    PubMed

    Saenz, Sunday R; Lewis, Russell J; Angier, Mike K; Wagner, Jarrad R

    2017-07-01

    Marijuana is the most commonly abused illicit drug worldwide. Marijuana is used for its euphoric and relaxing properties. However, marijuana use has been shown to result in impaired memory, cognitive skills and psychomotor function. The Federal Aviation Administration's Civil Aerospace Medical Institute conducts toxicological analysis on aviation fatalities. Due to severe trauma associated with aviation accidents, blood is not always available; therefore, the laboratory must rely on specimens other than blood for toxicological analysis in ~30-40% of cases. However, the postmortem distribution of cannabinoids has not been well characterized. The purpose of this research is to evaluate the distribution of Δ9-tetrahydrocannabinol (THC), and its metabolites, 11-hydroxy-tetrahydrocannabinol (11-OH-THC) and THC-COOH, in postmortem fluid and tissue specimens from 11 fatal aviation accident cases (2014-2015) previously found positive for cannabinoids. Specimens evaluated, when available, included: blood, urine, vitreous humor, liver, lung, kidney, spleen, muscle, brain, heart and bile. We developed and validated (following SWGTOX guidelines) a sensitive and robust method using solid-phase extraction and liquid chromatography-tandem mass spectrometry to identify and quantify THC, 11-OH-THC and THC-COOH in postmortem fluids and tissues. The method readily identified and quantified these cannabinoids in postmortem fluids and tissues below 1 ng/mL. Qualitative cannabinoid results within each case were comparable between blood and non-blood specimens. However, there was no consistent distribution of the cannabinoids between blood and any other fluids or tissues. Therefore, while quantitative interpretation of non-blood postmortem fluid and tissues samples is not prudent, a majority of the non-blood specimens tested could be suitable alternative/supplemental choices for qualitative cannabinoid detection. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  14. A double-blind, placebo-controlled randomized clinical trial to evaluate the efficacy of tranexamic acid in irrigant solution on blood loss during percutaneous nephrolithotomy: a pilot study from tertiary care center of North India.

    PubMed

    Bansal, Ankur; Arora, Aditi

    2017-08-01

    To evaluate the efficacy and safety of 0.1% tranexamic acid in irrigant fluid in reducing blood loss during PCNL. The study involved 400 patients who were planned for PCNL and were prospectively randomized into two equal groups. In tranexamic group, 0.1% tranexamic acid was given in irrigant fluid, while in placebo group, distilled water was added to irrigant fluid during surgery. Operative data were recorded which included fall in hemoglobin, total blood loss, operative time, irrigation fluid, length of stay in hospital, requirement of blood transfusion, complications related to PCNL and adverse events of tranexamic acid. Baseline parameters were comparable between two groups. The fall in hemoglobin and total blood loss in the tranexamic group was significantly lower than placebo group (1.71 vs. 2.67 gm/dL, 154.55 vs. 212.61 mL, respectively, p < 0.0001). Operative time, amount of irrigation fluid used and hospital stay of tranexamic group were significantly less compared to placebo (p < 0.05). Complete stone clearance rate was 88% in tranexamic group versus 82% in placebo (p = 0.12). The blood transfusion requirement was significantly lower in the tranexamic group versus placebo (5 vs. 12.5%, p = 0.012), as was the complication rate (19 vs. 28%, p = 0.044). The requirement of angioembolization in the tranexamic group was significantly less as compared to placebo (0.5 vs. 4%, p = 0.03). No adverse events related to administration of tranexamic acid were noted. 0.1% tranexamic acid in irrigant fluid is safe and significantly reduces perioperative blood loss and requirement of blood transfusion during percutaneous nephrolithotomy. It is associated with lower perioperative complication rates.

  15. Osmolality Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... osmotic gap, tests for blood sodium, blood urea nitrogen (BUN) , and glucose must be performed to calculate ...

  16. Oxygen supersaturated fluid using fine micro/nanobubbles

    PubMed Central

    Matsuki, Noriaki; Ishikawa, Takuji; Ichiba, Shingo; Shiba, Naoki; Ujike, Yoshihito; Yamaguchi, Takami

    2014-01-01

    Microbubbles show peculiar properties, such as shrinking collapse, long lifetime, high gas solubility, negative electric charge, and free radical production. Fluids supersaturated with various gases can be easily generated using microbubbles. Oxygen microbubble fluid can be very useful for oxygen delivery to hypoxic tissues. However, there have been no reports of comparative investigations into adding fluids containing oxygen fine micro/nanobubbles (OFM-NBs) to common infusion solutions in daily medical care. In this study, it was demonstrated that OFMNBs can generate oxygen-supersaturated fluids, and they may be sufficiently small to infuse safely into blood vessels. It was found that normal saline solution is preferable for generating an oxygen-rich infusion fluid, which is best administered as a 30-minute intravenous infusion. It was also concluded that dextran solution is suitable for drug delivery substances packing oxygen gas over a 1-hour intravenous infusion. In addition, normal saline solution containing OFMNBs was effective for improving blood oxygenation. Thus, the use of OFMNB-containing fluids is a potentially effective novel method for improving blood oxygenation in cases involving hypoxia, ischemic diseases, infection control, and anticancer chemoradiation therapies. PMID:25285003

  17. Oxygen supersaturated fluid using fine micro/nanobubbles.

    PubMed

    Matsuki, Noriaki; Ishikawa, Takuji; Ichiba, Shingo; Shiba, Naoki; Ujike, Yoshihito; Yamaguchi, Takami

    2014-01-01

    Microbubbles show peculiar properties, such as shrinking collapse, long lifetime, high gas solubility, negative electric charge, and free radical production. Fluids supersaturated with various gases can be easily generated using microbubbles. Oxygen microbubble fluid can be very useful for oxygen delivery to hypoxic tissues. However, there have been no reports of comparative investigations into adding fluids containing oxygen fine micro/nanobubbles (OFM-NBs) to common infusion solutions in daily medical care. In this study, it was demonstrated that OFMNBs can generate oxygen-supersaturated fluids, and they may be sufficiently small to infuse safely into blood vessels. It was found that normal saline solution is preferable for generating an oxygen-rich infusion fluid, which is best administered as a 30-minute intravenous infusion. It was also concluded that dextran solution is suitable for drug delivery substances packing oxygen gas over a 1-hour intravenous infusion. In addition, normal saline solution containing OFMNBs was effective for improving blood oxygenation. Thus, the use of OFMNB-containing fluids is a potentially effective novel method for improving blood oxygenation in cases involving hypoxia, ischemic diseases, infection control, and anticancer chemoradiation therapies.

  18. Diagnosis of tuberculous pleurisy with combination of adenosine deaminase and interferon-γ immunospot assay in a tuberculosis-endemic population: A prospective cohort study.

    PubMed

    Xu, Han-Yan; Li, Cheng-Ye; Su, Shan-Shan; Yang, Li; Ye, Min; Ye, Jun-Ru; Ke, Pei-Pei; Chen, Cheng-Shui; Xie, Yu-Peng; Li, Yu-Ping

    2017-11-01

    The aim of this study was to identify the optimal cut-off value of T cell enzyme-linked immunospot assay for tuberculosis (T-SPOT.TB) and evaluate its diagnostic performance alone (in the peripheral blood) or in combination with the adenosine deaminase (ADA) activity test (in peripheral blood and the pleural fluid) in patients with tuberculous pleurisy.Adult patients presenting with pleural effusion were included in this prospective cohort study. Tuberculous pleurisy was diagnosed by T-SPOT.TB in peripheral blood and a combination of T-SPOT.TB and ADA activity test in pleural fluid and peripheral blood. Receiver operating characteristic (ROC) curve in combination with multivariate logistic regression was used to evaluate the diagnostic performance of the assays.Among a total of 189 patients with suspected tuberculous pleurisy who were prospectively enrolled in this study, 177 patients were validated for inclusion in the final analysis. ROC analysis revealed that the area under the ROC curve (AUC) for T-SPOT.TB in pleural fluid and peripheral blood was 0.918 and 0.881, respectively, and for the ADA activity test in pleural fluid was 0.944. In addition, 95.5 spot-forming cells (SFCs)/2.5 × 10 cells were determined as the optimal cut-off value for T-SPOT.TB in pleural fluid. Parallel combination of T-SPOT.TB and ADA activity test in pleural fluid showed increased sensitivity (96.9%) and specificity (87.5%), whereas serial combination showed increased specificity (97.5%). The combination of 3 assays had the highest sensitivity at 97.9%, with an AUC value of 0.964.T-SPOT.TB in pleural fluid performed better than that in peripheral blood and the ADA activity test in pleural fluid for tuberculous pleurisy diagnosis. The optimal cut-off value of T-SPOT.TB in pleural fluid was 95.5 SFCs/2.5 × 10 cells. Combination of 3 assays might be a promising approach for tuberculous pleurisy diagnosis. Copyright © 2017 The Authors. Published by Wolters Kluwer Health, Inc. All rights reserved.

  19. Diagnosis of tuberculous pleurisy with combination of adenosine deaminase and interferon-γ immunospot assay in a tuberculosis-endemic population

    PubMed Central

    Xu, Han-Yan; Li, Cheng-Ye; Su, Shan-Shan; Yang, Li; Ye, Min; Ye, Jun-Ru; Ke, Pei-Pei; Chen, Cheng-Shui; Xie, Yu-Peng; Li, Yu-Ping

    2017-01-01

    Abstract The aim of this study was to identify the optimal cut-off value of T cell enzyme-linked immunospot assay for tuberculosis (T-SPOT.TB) and evaluate its diagnostic performance alone (in the peripheral blood) or in combination with the adenosine deaminase (ADA) activity test (in peripheral blood and the pleural fluid) in patients with tuberculous pleurisy. Adult patients presenting with pleural effusion were included in this prospective cohort study. Tuberculous pleurisy was diagnosed by T-SPOT.TB in peripheral blood and a combination of T-SPOT.TB and ADA activity test in pleural fluid and peripheral blood. Receiver operating characteristic (ROC) curve in combination with multivariate logistic regression was used to evaluate the diagnostic performance of the assays. Among a total of 189 patients with suspected tuberculous pleurisy who were prospectively enrolled in this study, 177 patients were validated for inclusion in the final analysis. ROC analysis revealed that the area under the ROC curve (AUC) for T-SPOT.TB in pleural fluid and peripheral blood was 0.918 and 0.881, respectively, and for the ADA activity test in pleural fluid was 0.944. In addition, 95.5 spot-forming cells (SFCs)/2.5 × 105 cells were determined as the optimal cut-off value for T-SPOT.TB in pleural fluid. Parallel combination of T-SPOT.TB and ADA activity test in pleural fluid showed increased sensitivity (96.9%) and specificity (87.5%), whereas serial combination showed increased specificity (97.5%). The combination of 3 assays had the highest sensitivity at 97.9%, with an AUC value of 0.964. T-SPOT.TB in pleural fluid performed better than that in peripheral blood and the ADA activity test in pleural fluid for tuberculous pleurisy diagnosis. The optimal cut-off value of T-SPOT.TB in pleural fluid was 95.5 SFCs/2.5 × 105 cells. Combination of 3 assays might be a promising approach for tuberculous pleurisy diagnosis. PMID:29381918

  20. A Rapid Capillary-Pressure Driven Micro-Channel to Demonstrate Newtonian Fluid Behavior of Zebrafish Blood at High Shear Rates.

    PubMed

    Lee, Juhyun; Chou, Tzu-Chieh; Kang, Dongyang; Kang, Hanul; Chen, Junjie; Baek, Kyung In; Wang, Wei; Ding, Yichen; Carlo, Dino Di; Tai, Yu-Chong; Hsiai, Tzung K

    2017-05-16

    Blood viscosity provides the rheological basis to elucidate shear stress underlying developmental cardiac mechanics and physiology. Zebrafish is a high throughput model for developmental biology, forward-genetics, and drug discovery. The micro-scale posed an experimental challenge to measure blood viscosity. To address this challenge, a microfluidic viscometer driven by surface tension was developed to reduce the sample volume required (3μL) for rapid (<2 min) and continuous viscosity measurement. By fitting the power-law fluid model to the travel distance of blood through the micro-channel as a function of time and channel configuration, the experimentally acquired blood viscosity was compared with a vacuum-driven capillary viscometer at high shear rates (>500 s -1 ), at which the power law exponent (n) of zebrafish blood was nearly 1 behaving as a Newtonian fluid. The measured values of whole blood from the micro-channel (4.17cP) and the vacuum method (4.22cP) at 500 s -1 were closely correlated at 27 °C. A calibration curve was established for viscosity as a function of hematocrits to predict a rise and fall in viscosity during embryonic development. Thus, our rapid capillary pressure-driven micro-channel revealed the Newtonian fluid behavior of zebrafish blood at high shear rates and the dynamic viscosity during development.

  1. Fabrication of Multscale Fractal-Like Structures by Controlling Fluid Interface Instability

    PubMed Central

    Islam, Tanveer ul; Gandhi, Prasanna S.

    2016-01-01

    Nature, in quest for the best designs has shaped its vital systems into fractal geometries. Effectual way of spontaneous fabrication of scalable, ordered fractal-like structures by controlling Saffman-Taylor instability in a lifted Hele-Shaw cell is deployed here. In lifted Hele-Shaw cell uncontrolled penetration of low-viscosity fluid into its high-viscosity counterpart is known to develop irregular, non-repeatable, normally short-lived, branched patterns. We propose and characterize experimentally anisotropies in a form of spatially distributed pits on the cell plates to control initiation and further penetration of non-splitting fingers. The proposed control over shielding mechanism yields recipes for fabrication of families of ordered fractal-like patterns of multiple generations. As an example, we demonstrate and characterize fabrication of a Cayley tree fractal-like pattern. The patterns, in addition, are retained permanently by employing UV/thermally curable fluids. The proposed technique thus establishes solid foundation for bio-mimicking natural structures spanning multiple-scales for scientific and engineering use. PMID:27849003

  2. Fabrication of Multscale Fractal-Like Structures by Controlling Fluid Interface Instability

    NASA Astrophysics Data System (ADS)

    Islam, Tanveer Ul; Gandhi, Prasanna S.

    2016-11-01

    Nature, in quest for the best designs has shaped its vital systems into fractal geometries. Effectual way of spontaneous fabrication of scalable, ordered fractal-like structures by controlling Saffman-Taylor instability in a lifted Hele-Shaw cell is deployed here. In lifted Hele-Shaw cell uncontrolled penetration of low-viscosity fluid into its high-viscosity counterpart is known to develop irregular, non-repeatable, normally short-lived, branched patterns. We propose and characterize experimentally anisotropies in a form of spatially distributed pits on the cell plates to control initiation and further penetration of non-splitting fingers. The proposed control over shielding mechanism yields recipes for fabrication of families of ordered fractal-like patterns of multiple generations. As an example, we demonstrate and characterize fabrication of a Cayley tree fractal-like pattern. The patterns, in addition, are retained permanently by employing UV/thermally curable fluids. The proposed technique thus establishes solid foundation for bio-mimicking natural structures spanning multiple-scales for scientific and engineering use.

  3. Using Magnetic Fields to Control Convection during Protein Crystallization: Analysis and Validation Studies

    NASA Technical Reports Server (NTRS)

    Ramachandran, N.; Leslie, F. W.

    2004-01-01

    The effect of convection during the crystallization of proteins is not very well understood. In a gravitational field, convection is caused by crystal sedimentation and by solutal buoyancy induced flow and these can lead to crystal imperfections. While crystallization in microgravity can approach diffusion limited growth conditions (no convection), terrestrially strong magnetic fields can be used to control fluid flow and sedimentation effects. In this work, we develop the analysis for magnetic flow control and test the predictions using analog experiments. Specifically, experiments on solutal convection in a paramagnetic fluid were conducted in a strong magnetic field gradient using a dilute solution of Manganese Chloride. The observed flows indicate that the magnetic field can completely counter the settling effects of gravity locally and are consistent with the theoretical predictions presented. This phenomenon suggests that magnetic fields may be useful in mimicking the microgravity environment of space for some crystal growth ana biological applications where fluid convection is undesirable.

  4. Fluid Mechanics of Blood Clot Formation.

    PubMed

    Fogelson, Aaron L; Neeves, Keith B

    2015-01-01

    Intravascular blood clots form in an environment in which hydrodynamic forces dominate and in which fluid-mediated transport is the primary means of moving material. The clotting system has evolved to exploit fluid dynamic mechanisms and to overcome fluid dynamic challenges to ensure that clots that preserve vascular integrity can form over the wide range of flow conditions found in the circulation. Fluid-mediated interactions between the many large deformable red blood cells and the few small rigid platelets lead to high platelet concentrations near vessel walls where platelets contribute to clotting. Receptor-ligand pairs with diverse kinetic and mechanical characteristics work synergistically to arrest rapidly flowing cells on an injured vessel. Variations in hydrodynamic stresses switch on and off the function of key clotting polymers. Protein transport to, from, and within a developing clot determines whether and how fast it grows. We review ongoing experimental and modeling research to understand these and related phenomena.

  5. Fluid Mechanics of Blood Clot Formation

    NASA Astrophysics Data System (ADS)

    Fogelson, Aaron L.; Neeves, Keith B.

    2015-01-01

    Intravascular blood clots form in an environment in which hydrodynamic forces dominate and in which fluid-mediated transport is the primary means of moving material. The clotting system has evolved to exploit fluid dynamic mechanisms and to overcome fluid dynamic challenges to ensure that clots that preserve vascular integrity can form over the wide range of flow conditions found in the circulation. Fluid-mediated interactions between the many large deformable red blood cells and the few small rigid platelets lead to high platelet concentrations near vessel walls where platelets contribute to clotting. Receptor-ligand pairs with diverse kinetic and mechanical characteristics work synergistically to arrest rapidly flowing cells on an injured vessel. Variations in hydrodynamic stresses switch on and off the function of key clotting polymers. Protein transport to, from, and within a developing clot determines whether and how fast it grows. We review ongoing experimental and modeling research to understand these and related phenomena.

  6. Blood Pressure Responses and Mineral Ocorticoid Levels in the Suspended Rat Model for Weightlessness

    NASA Technical Reports Server (NTRS)

    Musacchia, X. J.; Steffen, J. M.

    1985-01-01

    Cardiovascular responses and fluid/electrolyte shifts seen during space flight are attributed to cephalad redistribution of vascular fluid. The antiorthostatic (AO) rat (suspended head down tilted, 15-20 deg) is used to model these responses. Current studies show that elevated blood pressures in A0 rats are sustained for periods up to seven days. Comparisons are made with presuspension rats. Increased blood pressure in head down tilted subjects suggests a specific response to A0 positioning, potentially relatable to cephalad fluid shift. To assess a role for hormonal regulation of sodium excretion, serum aldosterone levels were measured.

  7. Discriminant analysis of Raman spectra for body fluid identification for forensic purposes.

    PubMed

    Sikirzhytski, Vitali; Virkler, Kelly; Lednev, Igor K

    2010-01-01

    Detection and identification of blood, semen and saliva stains, the most common body fluids encountered at a crime scene, are very important aspects of forensic science today. This study targets the development of a nondestructive, confirmatory method for body fluid identification based on Raman spectroscopy coupled with advanced statistical analysis. Dry traces of blood, semen and saliva obtained from multiple donors were probed using a confocal Raman microscope with a 785-nm excitation wavelength under controlled laboratory conditions. Results demonstrated the capability of Raman spectroscopy to identify an unknown substance to be semen, blood or saliva with high confidence.

  8. Physiologic mechanisms of circulatory and body fluid losses in weightlessness identified by mathematical modeling

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Srinivasan, R. S.; Charles, J. B.

    1993-01-01

    Central volume expansion due to fluid shifts in weightlessness is believed to activate adaptive reflexes which ultimately result in a reduction of the total circulating blood volume. However, the flight data suggests that a central volume overdistention does not persist, in which case some other factor or factors must be responsible for body fluid losses. We used a computer simulation to test the hypothesis that factors other than central volume overdistention are involved in the loss of blood volume and other body fluid volumes observed in weightlessness and in weightless simulations. Additionally, the simulation was used to identify these factors. The results predict that atrial volumes and pressures return to their prebedrest baseline values within the first day of exposure to head down tilt (HDT) as the blood volume is reduced by an elevated urine formation. They indicate that the mechanisms for large and prolonged body fluid losses in weightlessness is red cell hemoconcentration that elevates blood viscosity and peripheral resistance, thereby lowering capillary pressure. This causes a prolonged alteration of the balance of Starling forces, depressing the extracellular fluid volume until the hematocrit is returned to normal through a reduction of the red cell mass, which also allows some restoration of the plasma volume. We conclude that the red cell mass becomes the physiologic driver for a large 'undershoot' of the body fluid volumes after the normalization of atrial volumes and pressures.

  9. Pharmacokinetic Profile of Oral Cannabis in Humans: Blood and Oral Fluid Disposition and Relation to Pharmacodynamic Outcomes.

    PubMed

    Vandrey, Ryan; Herrmann, Evan S; Mitchell, John M; Bigelow, George E; Flegel, Ronald; LoDico, Charles; Cone, Edward J

    2017-03-01

    Most research on cannabis pharmacokinetics has evaluated inhaled cannabis, but oral ("edible") preparations comprise an increasing segment of the cannabis market. To assess oral cannabis pharmacokinetics and pharmacodynamics, healthy adults (N = 6 per dose) were administered cannabis brownies containing 10, 25 or 50 mg 9-tetrahydrocannabinol (THC). Whole blood and oral fluid specimens were obtained at baseline and then for 9 days post-exposure; 6 days in a residential research setting and 3 days as outpatients. Measures of subjective, cardiovascular and performance effects were obtained at baseline and for 8 h post-ingestion. The mean Cmax for THC in whole blood was 1, 3.5 and 3.3 ng/mL for the 10, 25 and 50 mg THC doses, respectively. The mean maximum concentration (Cmax) and mean time to maximum concentration (Tmax) of 11-OH-THC in whole blood were similar to THC. Cmax blood concentrations of THCCOOH were generally higher than THC and had longer Tmax values. The mean Tmax for THC in oral fluid occurred immediately following oral dose administration, and appear to reflect local topical residue rather than systemic bioavailbility. Mean Cmax oral fluid concentrations of THCCOOH were lower than THC, erratic over time and mean Tmax occurred at longer times than THC. The window of THC detection ranged from 0 to 22 h for whole blood (limit of quantitation (LOQ) = 0.5 ng/mL) and 1.9 to 22 h for oral fluid (LOQ = 1.0 ng/mL). Subjective drug and cognitive performance effects were generally dose dependent, peaked at 1.5-3 h post-administration, and lasted 6-8 h. Whole blood cannabinoid concentrations were significantly correlated with subjective drug effects. Correlations between blood cannabinoids and cognitive performance measures, and between oral fluid and all pharmacodynamic outcomes were either non-significant or not orderly by dose. Quantitative levels of cannabinoids in whole blood and oral fluid were low compared with levels observed following inhalation of cannabis. The route of administration is important for interpretation of cannabinoid toxicology. Published by Oxford University Press 2017. This work is written by (a) US Government employee(s) and is in the public domain in the US.

  10. Blood transfusion improves renal oxygenation and renal function in sepsis-induced acute kidney injury in rats.

    PubMed

    Zafrani, Lara; Ergin, Bulent; Kapucu, Aysegul; Ince, Can

    2016-12-20

    The effects of blood transfusion on renal microcirculation during sepsis are unknown. This study aimed to investigate the effect of blood transfusion on renal microvascular oxygenation and renal function during sepsis-induced acute kidney injury. Twenty-seven Wistar albino rats were randomized into four groups: a sham group (n = 6), a lipopolysaccharide (LPS) group (n = 7), a LPS group that received fluid resuscitation (n = 7), and a LPS group that received blood transfusion (n = 7). The mean arterial blood pressure, renal blood flow, and renal microvascular oxygenation within the kidney cortex were recorded. Acute kidney injury was assessed using the serum creatinine levels, metabolic cost, and histopathological lesions. Nitrosative stress (expression of endothelial (eNOS) and inducible nitric oxide synthase (iNOS)) within the kidney was assessed by immunohistochemistry. Hemoglobin levels, pH, serum lactate levels, and liver enzymes were measured. Fluid resuscitation and blood transfusion both significantly improved the mean arterial pressure and renal blood flow after LPS infusion. Renal microvascular oxygenation, serum creatinine levels, and tubular damage significantly improved in the LPS group that received blood transfusion compared to the group that received fluids. Moreover, the renal expression of eNOS was markedly suppressed under endotoxin challenge. Blood transfusion, but not fluid resuscitation, was able to restore the renal expression of eNOS. However, there were no significant differences in lactic acidosis or liver function between the two groups. Blood transfusion significantly improved renal function in endotoxemic rats. The specific beneficial effect of blood transfusion on the kidney could have been mediated in part by the improvements in renal microvascular oxygenation and sepsis-induced endothelial dysfunction via the restoration of eNOS expression within the kidney.

  11. Contactless diagnostics of biophysical parameters of skin and blood on the basis of approximating functions for radiation fluxes scattered by skin

    NASA Astrophysics Data System (ADS)

    Lisenko, S. A.; Kugeiko, M. M.

    2014-03-01

    Approximating expressions are derived to calculate spectral and spatial characteristics of diffuse reflection of light from a two-layer medium mimicking human skin. The effectiveness of the use of these expressions in the optical diagnosis of skin biophysical parameters (tissue scattering parameters, concentration of melanin in the epidermis, concentration of total haemoglobin and bilirubin in the tissues of the dermis) and content of haemoglobin derivatives in blood (oxy-, deoxy-, met-, carboxy- and sulfhaemoglobin) is analysed numerically. The methods are proposed to determine in realtime these parameters without contact of the measuring instrument with the patient's body.

  12. Peritonitis - secondary

    MedlinePlus

    ... blood pressure. Tests may include: Blood culture Blood chemistry, including pancreatic enzymes Complete blood count Liver and kidney function tests X-rays or CT scan Peritoneal fluid culture Urinalysis

  13. Long-range ordered vorticity patterns in living tissue induced by cell division

    NASA Astrophysics Data System (ADS)

    Rossen, Ninna S.; Tarp, Jens M.; Mathiesen, Joachim; Jensen, Mogens H.; Oddershede, Lene B.

    2014-12-01

    In healthy blood vessels with a laminar blood flow, the endothelial cell division rate is low, only sufficient to replace apoptotic cells. The division rate significantly increases during embryonic development and under halted or turbulent flow. Cells in barrier tissue are connected and their motility is highly correlated. Here we investigate the long-range dynamics induced by cell division in an endothelial monolayer under non-flow conditions, mimicking the conditions during vessel formation or around blood clots. Cell divisions induce long-range, well-ordered vortex patterns extending several cell diameters away from the division site, in spite of the system’s low Reynolds number. Our experimental results are reproduced by a hydrodynamic continuum model simulating division as a local pressure increase corresponding to a local tension decrease. Such long-range physical communication may be crucial for embryonic development and for healing tissue, for instance around blood clots.

  14. Synthetic RNAs Mimicking Structural Domains in the Foot-and-Mouth Disease Virus Genome Elicit a Broad Innate Immune Response in Porcine Cells Triggered by RIG-I and TLR Activation.

    PubMed

    Borrego, Belén; Rodríguez-Pulido, Miguel; Revilla, Concepción; Álvarez, Belén; Sobrino, Francisco; Domínguez, Javier; Sáiz, Margarita

    2015-07-17

    The innate immune system is the first line of defense against viral infections. Exploiting innate responses for antiviral, therapeutic and vaccine adjuvation strategies is being extensively explored. We have previously described, the ability of small in vitro RNA transcripts, mimicking the sequence and structure of different domains in the non-coding regions of the foot-and-mouth disease virus (FMDV) genome (ncRNAs), to trigger a potent and rapid innate immune response. These synthetic non-infectious molecules have proved to have a broad-range antiviral activity and to enhance the immunogenicity of an FMD inactivated vaccine in mice. Here, we have studied the involvement of pattern-recognition receptors (PRRs) in the ncRNA-induced innate response and analyzed the antiviral and cytokine profiles elicited in swine cultured cells, as well as peripheral blood mononuclear cells (PBMCs).

  15. Deliberate sulphonylurea poisoning mimicking hyperinsulinaemia of infancy

    PubMed Central

    Owen, L.; Ellis, M.; Shield, J.

    2000-01-01

    A 6 month old child presenting with seizures was found to be hypoglycaemic secondary to hyperinsulinism. A family history of type II diabetes prompted estimation of sulphonylurea in the baby's blood, which was found to be high. A multidisciplinary case conference concluded that the sulphonylurea ingestion was likely to be the result of Munchausen syndrome by proxy. When investigating hypoglycaemia of infancy this possibility should be considered.

 PMID:10799433

  16. MicroRNA markers for forensic body fluid identification obtained from microarray screening and quantitative RT-PCR confirmation

    PubMed Central

    Zubakov, Dmitry; Boersma, Anton W. M.; Choi, Ying; van Kuijk, Patricia F.; Wiemer, Erik A. C.

    2010-01-01

    MicroRNAs (miRNAs) are non-protein coding molecules with important regulatory functions; many have tissue-specific expression patterns. Their very small size in principle makes them less prone to degradation processes, unlike messenger RNAs (mRNAs), which were previously proposed as molecular tools for forensic body fluid identification. To identify suitable miRNA markers for forensic body fluid identification, we first screened total RNA samples derived from saliva, semen, vaginal secretion, and venous and menstrual blood for the expression of 718 human miRNAs using a microarray platform. All body fluids could be easily distinguished from each other on the basis of complete array-based miRNA expression profiles. Results from quantitative reverse transcription PCR (RT-PCR; TaqMan) assays for microarray candidate markers confirmed strong over-expression in the targeting body fluid of several miRNAs for venous blood and several others for semen. However, no candidate markers from array experiments for other body fluids such as saliva, vaginal secretion, or menstrual blood could be confirmed by RT-PCR. Time-wise degradation of venous blood and semen stains for at least 1 year under lab conditions did not significantly affect the detection sensitivity of the identified miRNA markers. The detection limit of the TaqMan assays tested for selected venous blood and semen miRNA markers required only subpicogram amounts of total RNA per single RT-PCR test, which is considerably less than usually needed for reliable mRNA RT-PCR detection. We therefore propose the application of several stable miRNA markers for the forensic identification of blood stains and several others for semen stain identification, using commercially available TaqMan assays. Additional work remains necessary in search for suitable miRNA markers for other forensically relevant body fluids. Electronic supplementary material The online version of this article (doi:10.1007/s00414-009-0402-3) contains supplementary material, which is available to authorized users. PMID:20145944

  17. [Methods of protein gradient determination for diagnostic use in the clinical laboratory].

    PubMed

    Schulz, D; Rothenhöfer, C

    1982-02-25

    Computed quotients of the concentrations of individual proteins in serum and in cerebrospinal fluid recorded in a semilogarithmic way against the hydrodynamic radius of the molecules may be connected and so give lineals, the positions of which are believed to estimate the actual function of the blood-brain-barrier (Felgenhauer et al. 1974; 1976). It is demonstrated by examinations of different samples of blood and cerebrospinal fluid, that both the described method and the simple measurement of total protein in cerebrospinal fluid are of the same power in their application to estimate the function of the blood-brain-barrier. However, the method introduced by Felgenhauer et al. enables to demonstrate immunoglobulins not having reached the cerebrospinal fluid by entering from the blood stream and so giving rise to diagnose a local humoral immune response within the central nervous system. In this way the method of Felgenhauer et al. gives advantages to the diagnostics of neurological diseases.

  18. Screening and confirmation of microRNA markers for forensic body fluid identification.

    PubMed

    Wang, Zheng; Zhang, Ji; Luo, Haibo; Ye, Yi; Yan, Jing; Hou, Yiping

    2013-01-01

    MicroRNAs (miRNAs, ∼22 nucleotides) are small, non-protein coding RNAs that regulate gene expression at the post-transcriptional level. MiRNAs can express in a tissue-specific manner, and have been introduced to forensic body fluid identification. In this study, we employed the qPCR-array (TaqMan(®) Array Human MicroRNA Cards) to screen the body fluid-specific miRNAs. Seven candidate miRNAs were identified as potentially body fluid-specific and could be used as forensically relevant body fluid markers: miR16 and miR486 for venous blood, miR888 and miR891a for semen, miR214 for menstrual blood, miR124a for vaginal secretions, and miR138-2 for saliva. The candidate miRNA markers were then validated via hydrolysis probes quantitative real-time polymerase chain reaction (TaqMan-qPCR). In addition, BestKeeper software was used to validate the expression stability of four genes, RNU44, RNU48, U6 and U6b, regularly used as reference genes (RGs) for studies involving forensic body fluids. The current study suggests that U6 could be used as a proper RG of miRNAs in forensic body fluid identification. The relative expression ratios (R) of miR486, miR888, miR214, miR16 and miR891a can differentiate the target body fluid from other body fluids that were tested in this study. The detection limit of TaqMan-qPCR of the five confirmed miRNA markers was 10pg of total RNA. The effect of time-wise degradation of blood stains and semen stains for 1 month under normal laboratory conditions was tested and did not significantly affect the detection results. Herein, this study proposes five body fluid-specific miRNAs for the forensic identification of venous blood, semen, and menstrual blood, of which miR486, miR888, and miR214 may be used as new markers for body fluid identification. Additional work remains necessary in search for suitable miRNA markers and stable RGs for forensic body fluid identification. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  19. Abdomen after a Puestow procedure: postoperative CT appearance, complications, and potential pitfalls.

    PubMed

    Freed, K S; Paulson, E K; Frederick, M G; Keogan, M T; Pappas, T N

    1997-06-01

    To evaluate the postoperative computed tomographic (CT) appearance, complications, and potential pitfalls after a Puestow procedure (lateral side-to-side pancreaticojejunostomy). Forty CT examinations were performed after the Puestow procedure in 20 patients. Images were retrospectively reviewed by three radiologists. The pancreaticojejunal anastomosis was identified at 30 examinations and was immediately anterior to the pancreatic body or tail. The anastomosis contained fluid or gas on 11 scans and oral contrast material on four scans. On 15 scans, the anastomosis appeared as collapsed bowel without gas, fluid, or oral contrast material. The Roux-en-Y loop was identified on 28 (70%) scans and contained fluid or gas on 16 scans and oral contrast material on six scans. The Roux-en-Y loop appeared as collapsed bowel on six scans. When the anastomosis or Roux-en-Y loop contained fluid and gas, the appearance mimicked that of a pancreatic or parapancreatic abscess. Peripancreatic stranding was present on 28 scans and was due to either ongoing pancreatitis or postoperative change. Complications included 15 transient fluid collections, three abscesses, four pseudocysts, one hematoma, and one small-bowel and Roux-en-Y obstruction. Knowledge of the anatomy after a Puestow procedure is essential for accurate interpretation of CT scans.

  20. Is pH paper an acceptable, low-cost alternative to the blood gas analyzer for determining pleural fluid pH?

    PubMed

    Lesho, E P; Roth, B J

    1997-11-05

    Our laboratory uses pH paper rather than a blood gas analyzer to measure pleural fluid pH to decrease cost and avoid analyzer malfunction due to viscous fluids. To compare these two methods of determining pleural fluid pH, 42 patients undergoing diagnostic or therapeutic thoracentesis had two 1-mL aliquots of pleural fluid anaerobically collected in a heparinized syringe and placed on ice. pH measurements were made using litmus paper (pHydron Vivid 6-8 brand litmus paper; MicroEssential Labs; Brooklyn, NY) and the model 995-Hb blood gas analyzer (AVL Instruments; Roswell, GA) within 1 h of collection. Agreement analysis was performed in three ways: on the entire group; in subcategories of complicated or uncomplicated parapneumonic effusions (<7.1, 7.1 to 7.3, >7.3); and in subcategories of poor prognosis or better prognosis malignant effusions(<7.3, >7.3). pH measured with pH paper was significantly more variable (SD=0.55, coefficient of variation [CV]=7.5%) than was pH measured with the blood gas analyzer (SD=0.11, CV=1.5%). There was no significant correlation between values obtained with the two techniques (r=-0.26, SD of the differences=0.59). Using the pH subcategories, there was 72% discordance in classification between litmus paper and arterial blood gas (ABG) determinations for patients with parapneumonic effusions. In patients with malignant effusions, there was 30% discordance. The pH values obtained by the ABG analyzer predicted tube thoracostomy 72% of the time, whereas the pH values obtained using pH paper were consistent only 36% of the time. Determination of pleural fluid pH using pH paper is unreliable and should not be considered an acceptable alternative to the blood gas analyzer. There is no need to determine pH on purulent samples. Hospital laboratories will be more likely to allow the use of the ABG analyzer on fluids other than blood if clinicians keep this in mind.

  1. Impact of color blindness on recognition of blood in body fluids.

    PubMed

    Reiss, M J; Labowitz, D A; Forman, S; Wormser, G P

    2001-02-12

    Color blindness is a common hereditary X-linked disorder. To investigate whether color blindness affects the ability to detect the presence of blood in body fluids. Ten color-blind subjects and 20 sex- and age-matched control subjects were shown 94 photographs of stool, urine, or sputum. Frank blood was present in 57 (61%) of the photographs. Surveys were done to determine if board-certified internists had ever considered whether color blindness would affect detection of blood and whether an inquiry on color blindness was included in their standard medical interview. Color-blind subjects were significantly less able to identify correctly whether pictures of body fluids showed blood compared with non-color-blind controls (P =.001); the lowest rate of correct identifications occurred with pictures of stool (median of 26 [70%] of 37 for color-blind subjects vs 36.5 [99%] of 37 for controls; P<.001). The more severely color-blind subjects were significantly less accurate than those with less severe color deficiency (P =.009). Only 2 (10%) of the 21 physicians had ever considered the possibility that color blindness might affect the ability of patients to detect blood, and none routinely asked their patients about color blindness. Color blindness impairs recognition of blood in body fluids. Color-blind individuals and their health care providers need to be made aware of this limitation.

  2. The endocrine system in space flight

    NASA Astrophysics Data System (ADS)

    Leach, C. S.; Johnson, P. C.; Cintron, N. M.

    Hormones are important effectors of the body's response to microgravity in the areas of fluid and electrolyte metabolism, erythropoiesis, and calcium metabolism. For many years antidiuretic hormone, cortisol and aldosterone have been considered the hormones most important for regulation of body fluid volume and blood levels of electrolytes, but they cannot account totally for losses of fluid and electrolytes during space flight. We have now measured atrial natriuretic factor (ANF), a hormone recently shown to regulate sodium and water excretion, in blood specimens obtained during flight. After 30 or 42 h of weightlessness, mean ANF was elevated. After 175 or 180 h, ANF had decreased by 59%, and it changed little between that time and soon after landing. There is probably an increase in ANF early inflight associated with the fluid shift, followed by a compensatory decrease in blood volume. Increased renal blood flow may cause the later ANF decrease. Erythropoietin (Ep), a hormone involved in the control of red blood cell production, was measured in blood samples taken during the first Spacelab mission and was significantly decreased on the second day of flight, suggesting also an increase in renal blood flow. Spacelab-2 investigators report that the active vitamin D metabolite 1α, 25-dihydroxyvitamin D 3 increased early in the flight, indicating that a stimulus for increased bone resorption occurs by 30 h after launch.

  3. Label-free viscosity measurement of complex fluids using reversal flow switching manipulation in a microfluidic channel

    PubMed Central

    Jun Kang, Yang; Ryu, Jeongeun; Lee, Sang-Joon

    2013-01-01

    The accurate viscosity measurement of complex fluids is essential for characterizing fluidic behaviors in blood vessels and in microfluidic channels of lab-on-a-chip devices. A microfluidic platform that accurately identifies biophysical properties of blood can be used as a promising tool for the early detections of cardiovascular and microcirculation diseases. In this study, a flow-switching phenomenon depending on hydrodynamic balancing in a microfluidic channel was adopted to conduct viscosity measurement of complex fluids with label-free operation. A microfluidic device for demonstrating this proposed method was designed to have two inlets for supplying the test and reference fluids, two side channels in parallel, and a junction channel connected to the midpoint of the two side channels. According to this proposed method, viscosities of various fluids with different phases (aqueous, oil, and blood) in relation to that of reference fluid were accurately determined by measuring the switching flow-rate ratio between the test and reference fluids, when a reverse flow of the test or reference fluid occurs in the junction channel. An analytical viscosity formula was derived to measure the viscosity of a test fluid in relation to that of the corresponding reference fluid using a discrete circuit model for the microfluidic device. The experimental analysis for evaluating the effects of various parameters on the performance of the proposed method revealed that the fluidic resistance ratio (RJL/RL, fluidic resistance in the junction channel (RJL) to fluidic resistance in the side channel (RL)) strongly affects the measurement accuracy. The microfluidic device with smaller RJL/RL values is helpful to measure accurately the viscosity of the test fluid. The proposed method accurately measured the viscosities of various fluids, including single-phase (Glycerin and plasma) and oil-water phase (oil vs. deionized water) fluids, compared with conventional methods. The proposed method was also successfully applied to measure viscosities of blood with varying hematocrits, chemically fixed RBCS, and channel sizes. Based on these experimental results, the proposed method can be effectively used to measure the viscosities of various fluids easily, without any fluorescent labeling and tedious calibration procedures. PMID:24404040

  4. High resolution melt curve analysis based on methylation status for human semen identification.

    PubMed

    Fachet, Caitlyn; Quarino, Lawrence; Karnas, K Joy

    2017-03-01

    A high resolution melt curve assay to differentiate semen from blood, saliva, urine, and vaginal fluid based on methylation status at the Dapper Isoform 1 (DACT1) gene was developed. Stains made from blood, saliva, urine, semen, and vaginal fluid were obtained from volunteers and DNA was isolated using either organic extraction (saliva, urine, and vaginal fluid) or Chelex ® 100 extraction (blood and semen). Extracts were then subjected to bisulfite modification in order to convert unmethylated cytosines to uracil, consequently creating sequences whose amplicons have melt curves that vary depending on their initial methylation status. When primers designed to amplify the promoter region of the DACT1 gene were used, DNA from semen samples was distinguishable from other fluids by a having a statistically significant lower melting temperature. The assay was found to be sperm-significant since semen from a vasectomized man produced a melting temperature similar to the non-semen body fluids. Blood and semen stains stored up to 5 months and tested at various intervals showed little variation in melt temperature indicating the methylation status was stable during the course of the study. The assay is a more viable method for forensic science practice than most molecular-based methods for body fluid stain identification since it is time efficient and utilizes instrumentation common to forensic biology laboratories. In addition, the assay is advantageous over traditional presumptive chemical methods for body fluid identification since results are confirmatory and the assay offers the possibility of multiplexing which may test for multiple body fluids simultaneously.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Na; Zhang, Peng; Kang, Wei

    Multiscale simulations of fluids such as blood represent a major computational challenge of coupling the disparate spatiotemporal scales between molecular and macroscopic transport phenomena characterizing such complex fluids. In this paper, a coarse-grained (CG) particle model is developed for simulating blood flow by modifying the Morse potential, traditionally used in Molecular Dynamics for modeling vibrating structures. The modified Morse potential is parameterized with effective mass scales for reproducing blood viscous flow properties, including density, pressure, viscosity, compressibility and characteristic flow dynamics of human blood plasma fluid. The parameterization follows a standard inverse-problem approach in which the optimal micro parameters aremore » systematically searched, by gradually decoupling loosely correlated parameter spaces, to match the macro physical quantities of viscous blood flow. The predictions of this particle based multiscale model compare favorably to classic viscous flow solutions such as Counter-Poiseuille and Couette flows. It demonstrates that such coarse grained particle model can be applied to replicate the dynamics of viscous blood flow, with the advantage of bridging the gap between macroscopic flow scales and the cellular scales characterizing blood flow that continuum based models fail to handle adequately.« less

  6. Population pharmacokinetic analysis of blood and joint synovial fluid concentrations of robenacoxib from healthy dogs and dogs with osteoarthritis.

    PubMed

    Silber, Hanna E; Burgener, Claudia; Letellier, Ingrid M; Peyrou, Mathieu; Jung, Martin; King, Jonathan N; Gruet, Philippe; Giraudel, Jerome M

    2010-12-01

    The purpose of this population analysis was to characterize the pharmacokinetic properties of robenacoxib in blood and stifle joint synovial fluid of dogs. Data were obtained from two studies: 1) 8 healthy Beagle dogs in which an acute inflammation was induced by injection of urate crystals into one joint; 2) 95 dogs from various breeds diagnosed with osteoarthritis (OA). Robenacoxib concentrations in blood and synovial fluid were measured using a validated HPLC-UV and LC-MS method. Non-linear mixed effects modeling was performed using NONMEM6. A two-compartment pharmacokinetic model with linear elimination was developed to describe blood concentrations of robenacoxib. Blood clearance in healthy animals was found to be 75% higher than in OA dogs. Synovial fluid concentrations were modeled using an effect-compartment-type model predicting longer residence times in OA dogs compared to healthy Beagles (e.g. concentrations above the IC(50) for COX-2, respectively, 16 h vs. 10 h at 1.5 mg/kg). Robenacoxib was found to reside longer at the effect site (inflamed joint) compared to blood in both healthy and OA dogs. These results may explain the good efficacy observed with once-daily dosing in clinical trials and the high safety index of robenacoxib in dogs.

  7. Discriminant Analysis of Raman Spectra for Body Fluid Identification for Forensic Purposes

    PubMed Central

    Sikirzhytski, Vitali; Virkler, Kelly; Lednev, Igor K.

    2010-01-01

    Detection and identification of blood, semen and saliva stains, the most common body fluids encountered at a crime scene, are very important aspects of forensic science today. This study targets the development of a nondestructive, confirmatory method for body fluid identification based on Raman spectroscopy coupled with advanced statistical analysis. Dry traces of blood, semen and saliva obtained from multiple donors were probed using a confocal Raman microscope with a 785-nm excitation wavelength under controlled laboratory conditions. Results demonstrated the capability of Raman spectroscopy to identify an unknown substance to be semen, blood or saliva with high confidence. PMID:22319277

  8. Residual cannabis levels in blood, urine and oral fluid following heavy cannabis use.

    PubMed

    Odell, Morris S; Frei, Matthew Y; Gerostamoulos, Dimitri; Chu, Mark; Lubman, Dan I

    2015-04-01

    An understanding of tetrahydrocannabinol (THC) kinetics and residual levels after cannabis use is essential in interpreting toxicology tests in body fluids from live subjects, particularly when used in forensic settings for drug abuse, traffic and interpersonal violence cases. However the current literature is largely based on laboratory studies using controlled cannabis dosages in experienced users, with limited research investigating the kinetics of residual THC concentrations in regular high dose cannabis users. Twenty-one dependent cannabis users were recruited at admission to two residential detoxification units in Melbourne, Australia. After being provided with information about, and consenting to, the study, subjects volunteered to provide once-daily blood, urine and oral fluid (saliva) samples for seven consecutive days following admission, involving cessation and abstinence from all cannabis use. Blood and oral fluid specimens were analysed for THC and urine specimens for the metabolite THC-COOH. In some subjects THC was detectable in blood for at least 7 days and oral fluid specimens were positive for THC up to 78 h after admission to the unit. Urinary THC-COOH concentrations exceeded 1000 ng/mL for some subjects 129 h after last use. The presented blood THC levels are higher and persist longer in some individuals than previously described, our understanding and interpretation of THC levels in long term heavy cannabis users may need to be reconsidered. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. [Effects of simulated body fluid flowing rate on bone-like apatite formation on porous calcium phosphate ceramics].

    PubMed

    Duan, You-rong; Liu, Ke-wei; Chen, Ji-yong; Zhang, Xing-dong

    2002-06-01

    Objective. Bone-like apatite formation on the surface of calcium phosphate ceramics was believed to be the necessary step that new bone grows on the ceramics and to be relative to the osteoinductivity of the material. This study aimed at investigating the influence of the flow rate of simulated body fluid (SBF) (2 ml/min) in skeletal muscle upon the formation of bone-like apatite on porous calcium phosphate ceramics. Method. The dynamic condition was realized by controlling the SBF flowing in/out of the sample chamber of 100 ml. The flow rate of 2 ml/min is close to that in human muscle environment. The pH and inorganic ionic composition of SBF are close to those of human body fluid. Result. Bone-like apatite formation was relatively easier to occur in static SBF than in dynamic SBF. Experiment with flowing SBF (dynamic SBF) is better in mimicking the living body fluid than static SBF. Conclusion. The results from dynamic SBF may more truly show the relation between apatite layer formation and osteoinduction in biomaterials than that from in vitro experiments before.

  10. Numerical Modeling of Interstitial Fluid Flow Coupled with Blood Flow through a Remodeled Solid Tumor Microvascular Network

    PubMed Central

    Soltani, M.; Chen, P.

    2013-01-01

    Modeling of interstitial fluid flow involves processes such as fluid diffusion, convective transport in extracellular matrix, and extravasation from blood vessels. To date, majority of microvascular flow modeling has been done at different levels and scales mostly on simple tumor shapes with their capillaries. However, with our proposed numerical model, more complex and realistic tumor shapes and capillary networks can be studied. Both blood flow through a capillary network, which is induced by a solid tumor, and fluid flow in tumor’s surrounding tissue are formulated. First, governing equations of angiogenesis are implemented to specify the different domains for the network and interstitium. Then, governing equations for flow modeling are introduced for different domains. The conservation laws for mass and momentum (including continuity equation, Darcy’s law for tissue, and simplified Navier–Stokes equation for blood flow through capillaries) are used for simulating interstitial and intravascular flows and Starling’s law is used for closing this system of equations and coupling the intravascular and extravascular flows. This is the first study of flow modeling in solid tumors to naturalistically couple intravascular and extravascular flow through a network. This network is generated by sprouting angiogenesis and consisting of one parent vessel connected to the network while taking into account the non-continuous behavior of blood, adaptability of capillary diameter to hemodynamics and metabolic stimuli, non-Newtonian blood flow, and phase separation of blood flow in capillary bifurcation. The incorporation of the outlined components beyond the previous models provides a more realistic prediction of interstitial fluid flow pattern in solid tumors and surrounding tissues. Results predict higher interstitial pressure, almost two times, for realistic model compared to the simplified model. PMID:23840579

  11. [The Contribution of Vascular Capacity and Blood Volume to Maintain Stable Blood Circulation during General Anesthesia].

    PubMed

    Shigemi, Kenji

    2016-05-01

    To maintain proper cardiac preload is one of the most effective procedures for the systemic circulation remaining stable. In particular, the balance between vascular capacity and total blood volume must be maintained within appropriate range by the administration of fluids, blood and/or vasoactive drugs with mean circulatory filling pressure (Pmcf), central venous pressure (CVP) or stroke volume variation (SVV). End-diastolic left ventricular volume (Ved) is theoretically the best index of cardiac preload; however, without transesophageal echocardbalanceiogram we cannot directly monitor Ved during anesthesia. The infused fluid volume remaining in intravascular space, the vascular capacity controlled by autonomic nervous system and/or vasoactive agents, and the unstressed blood volume properly mobilized to excess blood volume are the crucial factors to maintain cardiac output The knowledge of vascular physiology contribute the decision making to manipulate such factors to control blood circulation during general anesthesia. For example, CVP is usually maintained in the narrow range and seems to be stable; however, it must be changed just after the circulatory disturbances, such as acute bleeding, blood transfusion, and fluid infusion, and followed by gradual returning to initial value, because of the solid mechanism to preserve cardiac output

  12. Parameterizing the Morse Potential for Coarse-Grained Modeling of Blood Plasma

    PubMed Central

    Zhang, Na; Zhang, Peng; Kang, Wei; Bluestein, Danny; Deng, Yuefan

    2014-01-01

    Multiscale simulations of fluids such as blood represent a major computational challenge of coupling the disparate spatiotemporal scales between molecular and macroscopic transport phenomena characterizing such complex fluids. In this paper, a coarse-grained (CG) particle model is developed for simulating blood flow by modifying the Morse potential, traditionally used in Molecular Dynamics for modeling vibrating structures. The modified Morse potential is parameterized with effective mass scales for reproducing blood viscous flow properties, including density, pressure, viscosity, compressibility and characteristic flow dynamics of human blood plasma fluid. The parameterization follows a standard inverse-problem approach in which the optimal micro parameters are systematically searched, by gradually decoupling loosely correlated parameter spaces, to match the macro physical quantities of viscous blood flow. The predictions of this particle based multiscale model compare favorably to classic viscous flow solutions such as Counter-Poiseuille and Couette flows. It demonstrates that such coarse grained particle model can be applied to replicate the dynamics of viscous blood flow, with the advantage of bridging the gap between macroscopic flow scales and the cellular scales characterizing blood flow that continuum based models fail to handle adequately. PMID:24910470

  13. Changes in the blood-nerve barrier after sciatic nerve cold injury: indications supporting early treatment

    PubMed Central

    Li, Hao; Jia, Jian-ping; Xu, Min; Zhang, Lei

    2015-01-01

    Severe edema in the endoneurium can occur after non-freezing cold injury to the peripheral nerve, which suggests damage to the blood-nerve barrier. To determine the effects of cold injury on the blood-nerve barrier, the sciatic nerve on one side of Wistar rats was treated with low temperatures (3–5°C) for 2 hours. The contralateral sciatic nerve was used as a control. We assessed changes in the nerves using Evans blue as a fluid tracer and morphological methods. Excess fluid was found in the endoneurium 1 day after cold injury, though the tight junctions between cells remained closed. From 3 to 5 days after the cold injury, the fluid was still present, but the tight junctions were open. Less tracer leakage was found from 3 to 5 days after the cold injury compared with 1 day after injury. The cold injury resulted in a breakdown of the blood-nerve barrier function, which caused endoneurial edema. However, during the early period, the breakdown of the blood-nerve barrier did not include the opening of tight junctions, but was due to other factors. Excessive fluid volume produced a large increase in the endoneurial fluid pressure, prevented liquid penetration into the endoneurium from the microvasculature. These results suggest that drug treatment to patients with cold injuries should be administered during the early period after injury because it may be more difficult for the drug to reach the injury site through the microcirculation after the tissue fluid pressure becomes elevated. PMID:25878590

  14. Modern embalming, circulation of fluids, and the voyage through the human arterial system: Carl L. Barnes and the culture of immortality in America.

    PubMed

    Podgorny, Irina

    2011-01-01

    By considering the work of American embalmer, lawyer, and physician Carl Lewis Barnes (1872-1927), this paper analyzes the emergence of modern embalming in America. Barnes experimented with and exhibited the techniques by which embalming fluids travelled into the most remote cavities of the human body. In this sense, modem embalmers based their skills and methods on experimental medicine, turning the anatomy of blood vessels, physiology of circulation, and composition of blood into a circuit that allowed embalming fluids to move throughout the corpse. Embalmers in the late 19th century took ownership of the laws of hydrodynamics and the physiology of blood circulation to market their fluids and equipment, thus playing the role of physiologists of death, performing and demonstrating physiological experiments with dead bodies.

  15. Thyroglobulin

    MedlinePlus

    ... Gases Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid ... Medscape Today from Expert Review of Endocrinology and Metabolism [On-line information]. Available online at http://www. ...

  16. Gravitational haemodynamics and oedema prevention in the giraffe

    NASA Technical Reports Server (NTRS)

    Hargens, Alan R.; Millard, Ronald W.; Pettersson, Knut; Johansen, Kjell

    1987-01-01

    The question of how giraffes avoid pooling of blood and tissue fluid (edema) in dependent tissues of their extremities is addressed. As monitored by radiotelemetry, the blood and tissue fluid pressures that govern transcapillary exchange vary greatly with exercise. These pressures, combined with a tight skin layer, move fluid upward against gravity. The skin thus functions like a natural antigravity suit. Other mechanisms that prevent edema include precapillary vasoconstriction and low permeability of capillaries to plasma proteins.

  17. In-line Microwave Warmer for Blood and Intravenous Fluids. Phase 2.

    DTIC Science & Technology

    1988-02-15

    occuring in the battlefield often requires restoring normothermia and infusion of fluids, such as saline or blood, into the patient. These two...elevation is required to restore normal body temperature in response to hypothermic cardioplegic arrest induced prior to the operation. 6 1.2 System... Microfiltration Devices," Acta Annaesth Scand, 23:40- 45, 1979. [20] K Linko, K Hynynen, "Erythrocyte Damage Caused by the Haemotherm Microwave Blood Warmer

  18. Pleural fluid culture

    MedlinePlus

    ... Risks of thoracentesis are: Collapsed lung ( pneumothorax ) Excessive loss of blood Fluid reaccumulation Infection Pulmonary edema Respiratory distress Serious complications are uncommon Alternative Names Culture - pleural fluid Images Pleural culture References Chernecky CC, ...

  19. A randomized, double crossover study to investigate the influence of saline infusion on sleep apnea severity in men.

    PubMed

    Yadollahi, Azadeh; Gabriel, Joseph M; White, Laura H; Taranto Montemurro, Luigi; Kasai, Takatoshi; Bradley, T Douglas

    2014-10-01

    Obstructive sleep apnea (OSA) is commoner in patients with fluid-retaining states than in those without fluid retention, in men than in women, and worsens with aging. In men, OSA severity is related to the amount of fluid shifting out of the legs overnight, but a cause-effect relationship is not established. Our objective was to test the hypothesis that mimicking fluid overload during sleep would increase severity of OSA more in older (≥ 40 years) than in younger men (< 40 years). Randomized, single-blind, double crossover study. Research sleep laboratory. Seven older and 10 younger men with non-severe or no sleep apnea, matched for body mass index. During the control arm, normal saline was infused to keep the vein open. During intervention, subjects received an intravenous bolus of normal saline (22 mL/kg body weight) after sleep onset while they were wearing compression stockings to prevent fluid accumulation in the legs. Compared to younger men, infusion of similar amounts of saline in older men caused a greater increase in neck circumference (P < 0.05) and in the AHI (32.2 ± 22.1 vs. 2.2 ± 7.1, P = 0.002). Older men are more susceptible to the adverse effects of intravenous fluid loading on obstructive sleep apnea severity than younger men. This may be due to age-related differences in the amount of fluid accumulating in the neck or upper airway collapsibility in response to intravenous fluid loading. These possibilities remain to be tested in future studies. © 2014 Associated Professional Sleep Societies, LLC.

  20. A Teaspoon Pump for Pumping Blood with High Hydraulic Efficiency and Low Hemolysis Potential.

    PubMed

    Dame, Don

    1996-05-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required. © 1996 International Society for Artificial Organs.

  1. A teaspoon pump for pumping blood with high hydraulic efficiency and low hemolysis potential.

    PubMed

    Dame, D

    1996-06-01

    Virtually all blood pumps contain some kind of rubbing, sliding, closely moving machinery surfaces that are exposed to the blood being pumped. These valves, internal bearings, magnetic bearing position sensors, and shaft seals cause most of the problems with blood pumps. The original teaspoon pump design prevented the rubbing, sliding machinery surfaces from contacting the blood. However, the hydraulic efficiency was low because the blood was able to "slip around" the rotating impeller so that the blood itself never rotated fast enough to develop adequate pressure. An improved teaspoon blood pump has been designed and tested and has shown acceptable hydraulic performance and low hemolysis potential. The new pump uses a nonrotating "swinging" hose as the pump impeller. The fluid enters the pump through the center of the swinging hose; therefore, there can be no fluid slip between the revolving blood and the revolving impeller. The new pump uses an impeller that is comparable to a flexible garden hose. If the free end of the hose were swung around in a circle like half of a jump rope, the fluid inside the hose would rotate and develop pressure even though the hose impeller itself did not "rotate"; therefore, no rotating shaft seal or internal bearings are required.

  2. Blood flow and microgravity

    NASA Astrophysics Data System (ADS)

    Bureau, Lionel; Coupier, Gwennou; Dubois, Frank; Duperray, Alain; Farutin, Alexander; Minetti, Christophe; Misbah, Chaouqi; Podgorski, Thomas; Tsvirkun, Daria; Vysokikh, Mikhail

    2017-01-01

    The absence of gravity during space flight can alter cardio-vascular functions partially due to reduced physical activity. This affects the overall hemodynamics, and in particular the level of shear stresses to which blood vessels are submitted. Long-term exposure to space environment is thus susceptible to induce vascular remodeling through a mechanotransduction cascade that couples vessel shape and function with the mechanical cues exerted by the circulating cells on the vessel walls. Central to such processes, the glycocalyx - i.e. the micron-thick layer of biomacromolecules that lines the lumen of blood vessels and is directly exposed to blood flow - is a major actor in the regulation of biochemical and mechanical interactions. We discuss in this article several experiments performed under microgravity, such as the determination of lift force and collective motion in blood flow, and some preliminary results obtained in artificial microfluidic circuits functionalized with endothelium that offer interesting perspectives for the study of the interactions between blood and endothelium in healthy condition as well as by mimicking the degradation of glycocalyx caused by long space missions. A direct comparison between experiments and simulations is discussed. xml:lang="fr"

  3. Chloride Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... there is a problem with your body's electrolyte balance or acid-base (pH) balance and to monitor ...

  4. Efficacy and Safety of Stroke Volume Variation-Guided Fluid Therapy for Reducing Blood Loss and Transfusion Requirements During Radical Cystectomy: A Randomized Clinical Trial.

    PubMed

    Kong, Yu-Gyeong; Kim, Ji Yoon; Yu, Jihion; Lim, Jinwook; Hwang, Jai-Hyun; Kim, Young-Kug

    2016-05-01

    Radical cystectomy, which is performed to treat muscle-invasive bladder tumors, is among the most difficult urological surgical procedures and puts patients at risk of intraoperative blood loss and transfusion. Fluid management via stroke volume variation (SVV) is associated with reduced intraoperative blood loss. Therefore, we evaluated the efficacy and safety of SVV-guided fluid therapy for reducing blood loss and transfusion requirements in patients undergoing radical cystectomy.This study included 48 patients who underwent radical cystectomy, and these patients were randomly allocated to the control group and maintained at <10% SVV (n = 24) or allocated to the trial group and maintained at 10% to 20% SVV (n = 24). The primary endpoints were comparisons of the amounts of intraoperative blood loss and transfused red blood cells (RBCs) between the control and trial groups during radical cystectomy. Intraoperative blood loss was evaluated through the estimated blood loss and estimated red cell mass loss. The secondary endpoints were comparisons of the postoperative outcomes between groups.A total of 46 patients were included in the final analysis: 23 patients in the control group and 23 patients in the trial group. The SVV values in the trial group were significantly higher than in the control group. Estimated blood loss, estimated red cell mass loss, and RBC transfusion requirements in the trial group were significantly lower than in the control group (734.3 ± 321.5 mL vs 1096.5 ± 623.9 mL, P = 0.019; 274.1 ± 207.8 mL vs 553.1 ± 298.7 mL, P <0.001; 0.5 ± 0.8 units vs 1.9 ± 2.2 units, P = 0.005). There were no significant differences in postoperative outcomes between the two groups.SVV-guided fluid therapy (SVV maintained at 10%-20%) can reduce blood loss and transfusion requirements in patients undergoing radical cystectomy without resulting in adverse outcomes. These findings provide useful information for optimal fluid management during radical cystectomy.

  5. Micro-scale dynamic simulation of erythrocyte-platelet interaction in blood flow.

    PubMed

    AlMomani, T; Udaykumar, H S; Marshall, J S; Chandran, K B

    2008-06-01

    Platelet activation, adhesion, and aggregation on the blood vessel and implants result in the formation of mural thrombi. Platelet dynamics in blood flow is influenced by the far more numerous erythrocytes (RBCs). This is particularly the case in the smaller blood vessels (arterioles) and in constricted regions of blood flow (such as in valve leakage and hinge regions) where the dimensions of formed elements of blood become comparable with that of the flow geometry. In such regions, models to predict platelet motion, activation, aggregation and adhesion must account for platelet-RBC interactions. This paper studies platelet-RBC interactions in shear flows by performing simulations of micro-scale dynamics using a computational fluid dynamics (CFD) model. A level-set sharp-interface immersed boundary method is employed in the computations in which RBC and platelet boundaries are tracked on a two-dimensional Cartesian grid. The RBCs are assumed to have an elliptical shape and to deform elastically under fluid forces while the platelets are assumed to behave as rigid particles of circular shape. Forces and torques between colliding blood cells are modeled using an extension of the soft-sphere model for elliptical particles. RBCs and platelets are transported under the forces and torques induced by fluid flow and cell-cell and cell-platelet collisions. The simulations show that platelet migration toward the wall is enhanced with increasing hematocrit, in agreement with past experimental observations. This margination is seen to occur due to hydrodynamic forces rather than collisional forces or volumetric exclusion effects. The effect of fluid shear forces on the platelets increases exponentially as a function of hematocrit for the range of parameters covered in this study. The micro-scale analysis can be potentially employed to obtain a deterministic relationship between fluid forces and platelet activation and aggregation in blood flow past cardiovascular implants.

  6. Fate of pathogenic bacteria in microcosms mimicking human body sites.

    PubMed

    Castellani, Francesco; Ghidini, Valentina; Tafi, Maria Carla; Boaretti, Marzia; Lleo, Maria M

    2013-07-01

    During the infectious process, pathogens may reach anatomical sites where they are exposed to substances interfering with their growth. These substances can include molecules produced by the host, and his resident microbial population, as well as exogenous antibacterial drugs. Suboptimal concentrations of inhibitory molecules and stress conditions found in vivo (high or low temperatures, lack of oxygen, extreme pH) might induce in bacteria the activation of survival mechanisms blocking their division capability but allowing them to stay alive. These "dormant" bacteria can be reactivated in particular circumstances and would be able to express their virulence traits. In this study, it was evaluated the effect of some environmental conditions, such as optimal and suboptimal temperatures, direct light and antibiotic sub-inhibitory concentrations doses of antibiotic, on the human pathogens Escherichia coli and Enterococcus faecalis when incubated in fluids accumulated in the body of patients with different pathologies. It is shown that inoculation in a number of accumulated body fluids and the presence of gentamicin, reliable conditions encountered during pathological states, induce stress-responding strategies enabling bacteria to persist in microcosms mimicking the human body. Significant differences were detected in Gram-negative and Gram-positive species with E. faecalis surviving, as starved or viable but non-culturable forms, in any microcosm and condition tested and E. coli activating a viable but non-culturable state only in some clinical samples. The persistence of bacteria under these conditions, being non-culturable, might explain some recurrent infections without isolation of the causative agent after application of the standard microbiological methods.

  7. Blood viscosity monitoring during cardiopulmonary bypass based on pressure-flow characteristics of a Newtonian fluid.

    PubMed

    Okahara, Shigeyuki; Zu Soh; Takahashi, Shinya; Sueda, Taijiro; Tsuji, Toshio

    2016-08-01

    We proposed a blood viscosity estimation method based on pressure-flow characteristics of oxygenators used during cardiopulmonary bypass (CPB) in a previous study that showed the estimated viscosity to correlate well with the measured viscosity. However, the determination of the parameters included in the method required the use of blood, thereby leading to high cost of calibration. Therefore, in this study we propose a new method to monitor blood viscosity, which approximates the pressure-flow characteristics of blood considered as a non-Newtonian fluid with characteristics of a Newtonian fluid by using the parameters derived from glycerin solution to enable ease of acquisition. Because parameters used in the estimation method are based on fluid types, bovine blood parameters were used to calculate estimated viscosity (ηe), and glycerin parameters were used to estimate deemed viscosity (ηdeem). Three samples of whole bovine blood with different hematocrit levels (21.8%, 31.0%, and 39.8%) were prepared and perfused into the oxygenator. As the temperature changed from 37 °C to 27 °C, the oxygenator mean inlet pressure and outlet pressure were recorded for flows of 2 L/min and 4 L/min, and the viscosity was estimated. The value of deemed viscosity calculated with the glycerin parameters was lower than estimated viscosity calculated with bovine blood parameters by 20-33% at 21.8% hematocrit, 12-27% at 31.0% hematocrit, and 10-15% at 39.8% hematocrit. Furthermore, deemed viscosity was lower than estimated viscosity by 10-30% at 2 L/min and 30-40% at 4 L/min. Nevertheless, estimated and deemed viscosities varied with a similar slope. Therefore, this shows that deemed viscosity achieved using glycerin parameters may be capable of successfully monitoring relative viscosity changes of blood in a perfusing oxygenator.

  8. Design of a microfluidic system for red blood cell aggregation investigation.

    PubMed

    Mehri, R; Mavriplis, C; Fenech, M

    2014-06-01

    The purpose of this paper is to design a microfluidic apparatus capable of providing controlled flow conditions suitable for red blood cell (RBC) aggregation analysis. The linear velocity engendered from the controlled flow provides constant shear rates used to qualitatively analyze RBC aggregates. The design of the apparatus is based on numerical and experimental work. The numerical work consists of 3D numerical simulations performed using a research computational fluid dynamics (CFD) solver, Nek5000, while the experiments are conducted using a microparticle image velocimetry system. A Newtonian model is tested numerically and experimentally, then blood is tested experimentally under several conditions (hematocrit, shear rate, and fluid suspension) to be compared to the simulation results. We find that using a velocity ratio of 4 between the two Newtonian fluids, the layer corresponding to blood expands to fill 35% of the channel thickness where the constant shear rate is achieved. For blood experiments, the velocity profile in the blood layer is approximately linear, resulting in the desired controlled conditions for the study of RBC aggregation under several flow scenarios.

  9. The effects of recirculation flows on mass transfer from the arterial wall to flowing blood.

    PubMed

    Zhang, Zhiguo; Deng, Xiaoyan; Fan, Yubo; Guidoin, Robert

    2008-01-01

    Using a sudden tubular expansion as a model of an arterial stenosis, the effect of disturbed flow on mass transfer from the arterial wall to flowing blood was studied theoretically and tested experimentally by measuring the dissolution rate of benzoic acid disks forming the outer tube of a sudden tubular expansion. The study revealed that mass transfer from vessel wall to flowing fluid in regions of disturbed flow is independent of wall shear rates. The rate of mass transfer is significantly higher in regions of disturbed flow with a local maximum around the reattachment point where the wall shear rate is zero. The experimental study also revealed that the rate of mass transfer from the vessel wall to a flowing fluid is much higher in the presence of microspheres (as models of blood cells) in the flowing fluid and under the condition of pulsatile flow than in steady flow. These results imply that flow disturbance may enhance the transport of biochemicals and macromolecules, such as plasma proteins and lipoproteins synthesized within the blood vessel wall, from the blood vessel wall to flowing blood.

  10. Human Space Flight Challenges: Get a Leg Up

    NASA Technical Reports Server (NTRS)

    Lloyd, Charles W.

    2008-01-01

    This viewgraph presentation reviews some of the challenges that spaceflight imposes on the Human system. It describes four of the signs and symptoms of fluid shift in the astronaut when they fly in low earth orbit. It describes how the leg muscles influence blood flow It also outlines the four phases of "fluid shift" and where the majority of the central volume of blood is located in the body And it reviews other changes to the body systems as a result of Fluid Shift

  11. Flow of magnetic particles in blood with isothermal heating: A fractional model for two-phase flow

    NASA Astrophysics Data System (ADS)

    Ali, Farhad; Imtiaz, Anees; Khan, Ilyas; Sheikh, Nadeem Ahmad

    2018-06-01

    In the sixteenth century, medical specialists were of the conclusion that magnet can be utilized for the treatment or wipe out the illnesses from the body. On this basis, the research on magnet advances day by day for the treatment of different types of diseases in mankind. This study aims to investigate the effect of magnetic field and their applications in human body specifically in blood. Blood is a non-Newtonian fluid because its viscosity depends strongly on the fraction of volume occupied by red cells also called the hematocrit. Therefore, in this paper blood is considered as an example of non-Newtonian Casson fluid. The blood flow is considered in a vertical cylinder together with heat transfer due to mixed conviction caused by buoyancy force and the external pressure gradient. Effect of magnetic field on the velocities of blood and magnetic particles is also considered. The problem is modelled using the Caputo-Fabrizio derivative approach. The governing fractional partial differential equations are solved using Laplace and Hankel transformation techniques and exact solutions are obtained. Effects of different parameters such as Grashof number, Prandtl number, Casson fluid parameter and fractional parameters, and magnetic field are shown graphically. Both velocity profiles increase with the increase of Grashoff number and Casson fluid parameter and reduce with the increase of magnetic field.

  12. [State of the art in fluid and volume therapy : A user-friendly staged concept].

    PubMed

    Rehm, M; Hulde, N; Kammerer, T; Meidert, A S; Hofmann-Kiefer, K

    2017-03-01

    Adequate fluid therapy is highly important for the perioperative outcome of our patients. Both, hypovolemia and hypervolemia can lead to an increase in perioperative complications and can impair the outcome. Therefore, perioperative infusion therapy should be target-oriented. The main target is to maintain the patient's preoperative normovolemia by using a sophisticated, rational infusion strategy.Perioperative fluid losses should be discriminated from volume losses (surgical blood loss or interstitial volume losses containing protein). Fluid losses as urine or perspiratio insensibilis (0.5-1.0 ml/kg/h) should be replaced by balanced crystalloids in a ratio of 1:1. Volume therapy step 1: Blood loss up to a maximum value of 20% of the patient's blood volume should be replaced by balanced crystalloids in a ratio of 4(-5):1. Volume therapy step 2: Higher blood losses should be treated by using iso-oncotic, preferential balanced colloids in a ratio of 1:1. For this purpose hydroxyethyl starch can also be used perioperatively if there is no respective contraindication, such as sepsis, burn injuries, critically ill patients, renal impairment or renal replacement therapy, and severe coagulopathy. Volume therapy step 3: If there is an indication for red cell concentrates or coagulation factors, a differentiated application of blood and blood products should be performed.

  13. INCORPORATION OF LABELED NITRIC OXIDE INTO RESPIRATORY TRACT LINING FLUIDS AND BLOOD PLASMA DURING LUNG INFLAMMATION

    EPA Science Inventory

    Incorporation of labeled nitric oxide (N18O) into respiratory tract lining fluids and blood plasma during lung inflammation. Slade, R., Norwood, J., Crissman, K., McKee, J., Hatch, G. PTB, ETD, NHEERL, ORD, USEPA, Res. Tri. Pk., NC

    Our earlier studies have demonstrated t...

  14. Evaluation of MALDI-TOF mass spectrometry and Sepsityper Kit™ for the direct identification of organisms from sterile body fluids in a Canadian pediatric hospital.

    PubMed

    Tadros, Manal; Petrich, Astrid

    2013-01-01

    Matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) can be used to identify bacteria directly from positive blood and sterile fluid cultures. The authors evaluated a commercially available kit - the Sepsityper Kit (Bruker Daltonik, Germany) - and MALDI-TOF MS for the rapid identification of organisms from 80 flagged positive blood culture broths, of which 73 (91.2%) were blood culture specimens and seven (8.7%) were cerebrospinal fluid specimens, in comparison with conventional identification methods. Correct identification to the genus and species levels was obtained in 75 of 80 (93.8%) and 39 of 50 (78%) blood culture broths, respectively. Applying the blood culture analysis module, a newly developed software tool, improved the species identification of Gram-negative organisms from 94.7% to 100% and of Gram-positive organisms from 66.7% to 70%. MALDI-TOF MS is a promising tool for the direct identification of organisms cultured from sterile sites.

  15. Numerical study of magnetohydrodynamic pulsatile flow of Sutterby fluid through an inclined overlapping arterial stenosis in the presence of periodic body acceleration

    NASA Astrophysics Data System (ADS)

    Abbas, Z.; Shabbir, M. S.; Ali, N.

    2018-06-01

    In the present theoretical investigation, we have numerically simulated the problem of blood flow through an overlapping stenosed arterial blood vessel under the action of externally applied body acceleration and the periodic pressure gradient. The rheology of blood is characterized by the Sutterby fluid model. The blood is considered as an electrically conducting fluid. A steady uniform magnetic field is applied in the radial direction of the blood vessel. The governing nonlinear partial differential equations of the present flow together with prescribed boundary conditions are solved by employing explicit finite difference scheme. Results concerning the temporal distribution of velocity, flow rate, shear stress and resistance to the flow are displayed through graphs. The effects of various emerging parameters on the flow variables are analyzed and discussed in detail. The analysis reveals that the applied magnetic field and periodic body acceleration have considerable effects on the flow field.

  16. CFD analysis of multiphase blood flow within aorta and its thoracic branches of patient with coarctation of aorta using multiphase Euler - Euler approach

    NASA Astrophysics Data System (ADS)

    Ostrowski, Z.; Melka, B.; Adamczyk, W.; Rojczyk, M.; Golda, A.; Nowak, A. J.

    2016-09-01

    In the research a numerical Computational Fluid Dynamics (CFD) model of the pulsatile blood flow was created and analyzed. A real geometry of aorta and its thoracic branches of 8-year old patient diagnosed with a congenital heart defect - coarctation of aorta was used. The inlet boundary condition were implemented as the User Define Function according to measured values of volumetric blood flow. The blood flow was treated as multiphase: plasma, set as the primary fluid phase, was dominant with volume fraction of 0.585 and morphological elements of blood were treated in Euler-Euler approach as dispersed phases (with 90% Red Blood Cells and White Blood Cells as remaining solid volume fraction).

  17. Bacterial adenosine triphosphate as a measure of urinary tract infection

    NASA Technical Reports Server (NTRS)

    Chappelle, E. W.; Picciolo, G. L.

    1971-01-01

    Procedure detects and counts bacteria present in urine samples. Method also determines bacterial levels in other aqueous body fluids including lymph fluid, plasma, blood, spinal fluid, saliva and mucous.

  18. Determination of fluid extraction and osmotic conductance sigma K in the lung with hypertonic NaCl infusion. I. Theory.

    PubMed

    Hunter, M; Lee, J

    1992-11-01

    A dispersion and extraction model of the lung is developed to assess how the infusion of hypertonic saline into the pulmonary artery changes the gravimetric density of pulmonary venous blood. The dispersion analysis is built on the indicator dilution curve measured for the pulmonary circulation. The extraction model consists of microvascular and interstitial compartments separated by a permeable pulmonary endothelium. Because the density of fluid extracted by the hypertonic disturbance is lower than the blood density, the extraction leads to a decrease in blood density. Two cases of fluid extraction are analyzed, a hypertonic infusion to elevate the osmotic pressure in the pulmonary arterial blood in the form of a step function and an infusion performed over a period of 1 sec. Both cases show that the dispersion significantly attenuates the changes in osmotic pressure and density as they are transported by the blood along the pulmonary vasculature. Because the model has taken into account the effect of dispersion and pulmonary blood flow, the equations developed here provide the basis to calculate from the density change in pulmonary venous blood the characteristics of osmotic extraction intrinsic to the lung.

  19. 3D Reconstruction of Chick Embryo Vascular Geometries Using Non-invasive High-Frequency Ultrasound for Computational Fluid Dynamics Studies.

    PubMed

    Tan, Germaine Xin Yi; Jamil, Muhammad; Tee, Nicole Gui Zhen; Zhong, Liang; Yap, Choon Hwai

    2015-11-01

    Recent animal studies have provided evidence that prenatal blood flow fluid mechanics may play a role in the pathogenesis of congenital cardiovascular malformations. To further these researches, it is important to have an imaging technique for small animal embryos with sufficient resolution to support computational fluid dynamics studies, and that is also non-invasive and non-destructive to allow for subject-specific, longitudinal studies. In the current study, we developed such a technique, based on ultrasound biomicroscopy scans on chick embryos. Our technique included a motion cancelation algorithm to negate embryonic body motion, a temporal averaging algorithm to differentiate blood spaces from tissue spaces, and 3D reconstruction of blood volumes in the embryo. The accuracy of the reconstructed models was validated with direct stereoscopic measurements. A computational fluid dynamics simulation was performed to model fluid flow in the generated construct of a Hamburger-Hamilton (HH) stage 27 embryo. Simulation results showed that there were divergent streamlines and a low shear region at the carotid duct, which may be linked to the carotid duct's eventual regression and disappearance by HH stage 34. We show that our technique has sufficient resolution to produce accurate geometries for computational fluid dynamics simulations to quantify embryonic cardiovascular fluid mechanics.

  20. Unsteady Magnetized Flow and Heat Transfer of a Viscoelastic fluid over a Stretching Surface

    NASA Astrophysics Data System (ADS)

    Ghosh, Sushil Kumar

    2017-12-01

    This paper is to study the flow of heated ferro-fluid over a stretching sheet under the influence of magnetic field. The fluid considered in the present investigation is a mixture of blood as well as fluid-dispersed magnetic nano particles and under this context blood is found to be the appropriate choice of viscoelastic, Walter's B fluid. The objective of the present work is to study the effect of various parameters found in the mathematical analysis. Taking into account the blood has zero electrical conductivity, magnetization effect has been considered in the governing equation of the present study with the use of ferro-fluid dynamics principle. By introducing appropriate non-dimensional variables into the governing equations of unsteady two-dimensional flow of viscoelastic fluid with heat transfer are converted to a set of ordinary differential equations with appropriate boundary conditions. Newton's linearization technique has been employed for the solution of non-linear ordinary differential equations. Important results found in the present investigation are the substantial influence of ferro-magnetic parameter, Prandlt number and the parameter associated with the thermal conductivity on the flow and heat transfer. It is observed that the presence of magnetic dipole essentially reduces the flow velocity in the vertical direction and that helps to damage the cancer cells in the tumor region.

  1. Fluctuation of Ultrafiltration Coefficient of Hemodialysis Membrane During Reuse

    NASA Astrophysics Data System (ADS)

    Arif, Idam; Christin

    2010-12-01

    Hemodialysis treatment for patient with kidney failure is to regulate body fluid and to excrete waste products of metabolism. The patient blood and the dialyzing solution (dialysate) are flowed counter currently in a dialyzer to allow volume flux of fluid and diffusion of solutes from the blood to the dialysate through a semipermiable membrane. The volume flux of fluid depends on the hydrostatic and the osmotic pressure difference between the blood and the dialysate. It also depends on the membrane parameter that represents how the membrane allows the fluid and the solutes to move across as a result of the pressure difference, known as the ultrafiltration coefficient Kuf. The coefficient depends on the number and the radius of membrane pores for the movement of the fluids and the solutes across the membrane. The measured membrane ultrafiltration coefficient of reused dialyzer shows fluctuation between one uses to another without any significant trend of change. This indicates that the cleaning process carried out before reuse does not cause perfect removal of clots that happen in the previous use. Therefore the unblocked pores are forced to work hardly to obtain targeted volume flux in a certain time of treatment. This may increase the unblocked pore radius. Reuse is stopped when there is indication of blood leakage during the hemodialysis treatment.

  2. A new look at cerebrospinal fluid circulation

    PubMed Central

    2014-01-01

    According to the traditional understanding of cerebrospinal fluid (CSF) physiology, the majority of CSF is produced by the choroid plexus, circulates through the ventricles, the cisterns, and the subarachnoid space to be absorbed into the blood by the arachnoid villi. This review surveys key developments leading to the traditional concept. Challenging this concept are novel insights utilizing molecular and cellular biology as well as neuroimaging, which indicate that CSF physiology may be much more complex than previously believed. The CSF circulation comprises not only a directed flow of CSF, but in addition a pulsatile to and fro movement throughout the entire brain with local fluid exchange between blood, interstitial fluid, and CSF. Astrocytes, aquaporins, and other membrane transporters are key elements in brain water and CSF homeostasis. A continuous bidirectional fluid exchange at the blood brain barrier produces flow rates, which exceed the choroidal CSF production rate by far. The CSF circulation around blood vessels penetrating from the subarachnoid space into the Virchow Robin spaces provides both a drainage pathway for the clearance of waste molecules from the brain and a site for the interaction of the systemic immune system with that of the brain. Important physiological functions, for example the regeneration of the brain during sleep, may depend on CSF circulation. PMID:24817998

  3. Can the prevalence of high blood drug concentrations in a population be estimated by analysing oral fluid? A study of tetrahydrocannabinol and amphetamine.

    PubMed

    Gjerde, Hallvard; Verstraete, Alain

    2010-02-25

    To study several methods for estimating the prevalence of high blood concentrations of tetrahydrocannabinol and amphetamine in a population of drug users by analysing oral fluid (saliva). Five methods were compared, including simple calculation procedures dividing the drug concentrations in oral fluid by average or median oral fluid/blood (OF/B) drug concentration ratios or linear regression coefficients, and more complex Monte Carlo simulations. Populations of 311 cannabis users and 197 amphetamine users from the Rosita-2 Project were studied. The results of a feasibility study suggested that the Monte Carlo simulations might give better accuracies than simple calculations if good data on OF/B ratios is available. If using only 20 randomly selected OF/B ratios, a Monte Carlo simulation gave the best accuracy but not the best precision. Dividing by the OF/B regression coefficient gave acceptable accuracy and precision, and was therefore the best method. None of the methods gave acceptable accuracy if the prevalence of high blood drug concentrations was less than 15%. Dividing the drug concentration in oral fluid by the OF/B regression coefficient gave an acceptable estimation of high blood drug concentrations in a population, and may therefore give valuable additional information on possible drug impairment, e.g. in roadside surveys of drugs and driving. If good data on the distribution of OF/B ratios are available, a Monte Carlo simulation may give better accuracy. 2009 Elsevier Ireland Ltd. All rights reserved.

  4. Exposure to and precautions for blood and body fluids among workers in the funeral home franchises of Fort Worth, Texas.

    PubMed

    Nwanyanwu, O C; Tabasuri, T H; Harris, G R

    1989-08-01

    In 1982 the Centers for Disease Control published a set of recommendations and measures to protect persons working in health care settings or performing mortician services from possible exposure to the human immunodeficiency virus. This study of a number of funeral homes in the Fort Worth area was designed to determine the level of exposure of funeral home workers to blood and other body fluids and also to assess existing protective measures and practices in the industry. Workers in 22 funeral home franchises were surveyed with a predesigned questionnaire. Eighty-five responses from 20 of the 22 establishments were received. All 85 respondents admitted exposure of varying degrees to blood and body fluids. Sixty persons (70%) admitted heavy exposure, that is, frequent splashes. Analysis of the responses showed that 81 of 85 (95.3%) persons consistently wore gloves while performing tasks that might expose them to blood or other body fluids. Of the 60 persons who were heavily exposed, 43 wore long-sleeved gowns, 27 wore waterproof aprons, 17 surgical masks, and 15 goggles. The study further revealed that 52.9% (45/85) of the respondents had sustained accidental cuts or puncture wounds on the job. In light of these findings it is important to target educational efforts to persons in this industry to help them minimize their risks of infection with blood and body fluid borne infections.

  5. Complex and biofluids: From Maxwell to nowadays

    NASA Astrophysics Data System (ADS)

    Misbah, Chaouqi

    2009-11-01

    Complex fluids are the rule in biology and in many industrial applications. Typical examples are blood, cartilage, and polymer solutions. Unlike water (as well as domestic oils, soft clear drinks, and so on), the law(s) describing the behavior of complex fluids are not yet fully established. The complexity arises from strong coupling between microscopic scales (like the motion of a red blood cell in the case of blood, or a polymer molecule for a polymer solution) and the global scale of the flow (say at the scale of a blood artery, or a channel in laboratory experiments). In this issue entitled Complex and Biofluids a large panel of experimental and theoretical problems of complex fluids is exposed. The topics range from dilute polymer solutions, food products, to biology (blood flow, cell and tissue mechanics). One of the earliest model put forward as an attempt to describe a complex fluid was suggested a long time ago by James Clerk Maxwell (in 1867). Other famous scientists, like Einstein (in 1906), and Taylor (in 1932) have made important contributions to the field, but the topic of complex fluids still continues to pose a formidable challenge to science. This field has known during the past decade an unbelievable upsurge of interest in many branches of science (physics, mechanics, chemistry, biology, medical science, mathematics, and so on). Understanding complex fluids is viewed as one of the biggest challenge of the present century. This synthesis will provide a simple introduction to the topic, summarize the main contribution of this issue, and list major open questions in this field. To cite this article: C. Misbah, C. R. Physique 10 (2009).

  6. Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement.

    PubMed

    Pleitez, Miguel; von Lilienfeld-Toal, Hermann; Mäntele, Werner

    2012-01-01

    Interstitial fluid, i.e. the liquid present in the outermost layer of living cells of the skin between the Stratum corneum and the Stratum spinosum, was analyzed by Fourier transform infrared spectroscopy and by infrared spectroscopy using pulsed quantum cascade infrared lasers with photoacoustic detection. IR spectra of simulated interstitial fluid samples and of real samples from volunteers in the 850-1800cm(-1) range revealed that the major components of interstitial fluid are albumin and glucose within the physiological range, with only traces of sodium lactate if at all. The IR absorbance of glucose in interstitial fluid in vivo was probed in healthy volunteers using a setup with quantum cascade lasers and photoacoustic detection previously described. A variation of blood glucose between approx. 80mg/dl and 250mg/dl in the volunteers was obtained using the standard oral glucose tolerance test (OGT). At two IR wavelengths, 1054cm(-1) and 1084cm(-1), a reasonable correlation between the photoacoustic signal from the skin and the blood glucose value as determined by conventional glucose test sticks using blood from the finger tip was obtained. The infrared photoacoustic glucose signal (PAGS) may serve as the key for a non-invasive glucose measurement, since the glucose content in interstitial fluid closely follows blood glucose in the time course and in the level (a delay of some minutes and a level of approx. 80-90% of the glucose level in blood). Interstitial fluid is present in skin layers at a depth of only 15-50μm and is thus within the reach of mid-IR energy in an absorbance measurement. A non-invasive glucose measurement for diabetes patients based on mid-infrared quantum cascade lasers and photoacoustic detection could replace the conventional measurement using enzymatic test stripes and a drop of blood from the finger tip, thus reducing pain and being a cost-efficient alternative for millions of diabetes patients. Copyright © 2011 Elsevier B.V. All rights reserved.

  7. Infrared spectroscopic analysis of human interstitial fluid in vitro and in vivo using FT-IR spectroscopy and pulsed quantum cascade lasers (QCL): Establishing a new approach to non invasive glucose measurement

    NASA Astrophysics Data System (ADS)

    Pleitez, Miguel; von Lilienfeld-Toal, Hermann; Mäntele, Werner

    2012-01-01

    Interstitial fluid, i.e. the liquid present in the outermost layer of living cells of the skin between the Stratum corneum and the Stratum spinosum, was analyzed by Fourier transform infrared spectroscopy and by infrared spectroscopy using pulsed quantum cascade infrared lasers with photoacoustic detection. IR spectra of simulated interstitial fluid samples and of real samples from volunteers in the 850-1800 cm -1 range revealed that the major components of interstitial fluid are albumin and glucose within the physiological range, with only traces of sodium lactate if at all. The IR absorbance of glucose in interstitial fluid in vivo was probed in healthy volunteers using a setup with quantum cascade lasers and photoacoustic detection previously described [11]. A variation of blood glucose between approx. 80 mg/dl and 250 mg/dl in the volunteers was obtained using the standard oral glucose tolerance test (OGT). At two IR wavelengths, 1054 cm -1 and 1084 cm -1, a reasonable correlation between the photoacoustic signal from the skin and the blood glucose value as determined by conventional glucose test sticks using blood from the finger tip was obtained. The infrared photoacoustic glucose signal (PAGS) may serve as the key for a non-invasive glucose measurement, since the glucose content in interstitial fluid closely follows blood glucose in the time course and in the level (a delay of some minutes and a level of approx. 80-90% of the glucose level in blood). Interstitial fluid is present in skin layers at a depth of only 15-50 μm and is thus within the reach of mid-IR energy in an absorbance measurement. A non-invasive glucose measurement for diabetes patients based on mid-infrared quantum cascade lasers and photoacoustic detection could replace the conventional measurement using enzymatic test stripes and a drop of blood from the finger tip, thus reducing pain and being a cost-efficient alternative for millions of diabetes patients.

  8. Early Fluid and Protein Shifts in Men During Water Immersion

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.; Harrison, M. H.; Greenleaf, J. E.

    1987-01-01

    High precision blood and plasma densitometry was used to measure transvascular fluid shifts during water immersion to the neck. Six men (28-49 years) undertook 30 min of standing immersion in water at 35.0 +/- 0.2 C; immersion was preceded by 30 min control standing in air at 28 +/- 1 C. Blood was sampled from an antecubital catheter for determination of Blood Density (BD), Plasma Density (PD), Haematocrit (Ht), total Plasma Protein Concentration (PPC), and Plasma Albumin Concentration (PAC). Compared to control, significant decreases (p less than 0.01) in all these measures were observed after 20 min immersion. At 30 min, plasma volume had increased by 11.0 +/- 2.8%; the average density of the fluid shifted from extravascular fluid into the vascular compartment was 1006.3 g/l; albumin moved with the fluid and its albumin concentration was about one-third of the plasma protein concentration during early immersion. These calculations are based on the assumption that the F-cell ratio remained unchanged. No changes in erythrocyte water content during immersion were found. Thus, immersion-induced haemodilution is probably accompanied by protein (mainly albumin) augmentation which accompanies the intra-vascular fluid shift.

  9. Modeling Dark Energy Through AN Ising Fluid with Network Interactions

    NASA Astrophysics Data System (ADS)

    Luongo, Orlando; Tommasini, Damiano

    2014-12-01

    We show that the dark energy (DE) effects can be modeled by using an Ising perfect fluid with network interactions, whose low redshift equation of state (EoS), i.e. ω0, becomes ω0 = -1 as in the ΛCDM model. In our picture, DE is characterized by a barotropic fluid on a lattice in the equilibrium configuration. Thus, mimicking the spin interaction by replacing the spin variable with an occupational number, the pressure naturally becomes negative. We find that the corresponding EoS mimics the effects of a variable DE term, whose limiting case reduces to the cosmological constant Λ. This permits us to avoid the introduction of a vacuum energy as DE source by hand, alleviating the coincidence and fine tuning problems. We find fairly good cosmological constraints, by performing three tests with supernovae Ia (SNeIa), baryonic acoustic oscillation (BAO) and cosmic microwave background (CMB) measurements. Finally, we perform the Akaike information criterion (AIC) and Bayesian information criterion (BIC) selection criteria, showing that our model is statistically favored with respect to the Chevallier-Polarsky-Linder (CPL) parametrization.

  10. Characterization of a Piezoelectric AlN Beam Array in Air and Fluid for an Artificial Basilar Membrane

    NASA Astrophysics Data System (ADS)

    Jeon, Hyejin; Jang, Jongmoon; Kim, Sangwon; Choi, Hongsoo

    2018-03-01

    In this study, we present a piezoelectric artificial basilar membrane (ABM) composed of a 10-channel aluminum nitride beam array. Each beam varies in length from 1306 to 3194 μm for mimicking the frequency selectivity of the cochlea. To characterize the frequency selectivity of the ABM, we measured the mechanical displacement and piezoelectric output while applying acoustic stimulus at 100 dB sound pressure level in the range of 500 Hz-40 kHz. The resonance frequencies measured by mechanical displacement and piezoelectric output were in the range of 10.56-36.5 and 10.9-37.0 kHz, respectively. In addition, the electrical stimulus was applied to the ABMs to compare the mechanical responses in air and fluid. The measured resonance frequencies were in the range of 11.1-47.7 kHz in the air and 3.10-11.9 kHz in the fluid. Understanding the characteristics of the ABM is important for its potential use as a key technology for auditory prostheses.

  11. Clostridium difficile and C. difficile Toxin Testing

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... other infections, typically for an extended period, the balance of the normal flora in the digestive tract ...

  12. Utility of point of care test devices for infectious disease testing of blood and oral fluid and application to rapid testing in the field

    NASA Astrophysics Data System (ADS)

    Lee, Stephen R.; Kardos, Keith W.; Yearwood, Graham D.; Guillon, Geraldine B.; Kurtz, Lisa A.; Mokkapati, Vijaya K.

    2008-04-01

    Rapid, point of care (POC) testing has been increasingly deployed as an aid in the diagnosis of infectious disease, due to its ability to deliver rapid, actionable results. In the case of HIV, a number of rapid test devices have been FDA approved and CLIA-waived in order to enable diagnosis of HIV infection outside of traditional laboratory settings. These settings include STD clinics, community outreach centers and mobile testing units, as well as identifying HIV infection among pregnant women and managing occupational exposure to infection. The OraQuick ® rapid test platform has been widely used to identify HIV in POC settings, due to its simplicity, ease of use and the ability to utilize oral fluid as an alternative specimen to blood. More recently, a rapid test for antibodies to hepatitis C virus (HCV) has been developed on the same test platform which uses serum, plasma, finger-stick blood, venous blood and oral fluid. Clinical testing using this POC test device has shown that performance is equivalent to state of the art, laboratory based tests. These devices may be suitable for rapid field testing of blood and other body fluids for the presence of infectious agents.

  13. Sharps Injuries and Other Blood and Body Fluid Exposures Among Home Health Care Nurses and Aides

    PubMed Central

    Markkanen, Pia K.; Galligan, Catherine J.; Kriebel, David; Chalupka, Stephanie M.; Kim, Hyun; Gore, Rebecca J.; Sama, Susan R.; Laramie, Angela K.; Davis, Letitia

    2009-01-01

    Objectives. We quantified risks of sharp medical device (sharps) injuries and other blood and body fluid exposures among home health care nurses and aides, identified risk factors, assessed the use of sharps with safety features, and evaluated underreporting in workplace-based surveillance. Methods. We conducted a questionnaire survey and workplace-based surveillance, collaborating with 9 home health care agencies and 2 labor unions from 2006 to 2007. Results. Approximately 35% of nurses and 6.4% of aides had experienced at least 1 sharps injury during their home health care career; corresponding figures for other blood and body fluid exposures were 15.1% and 6.7%, respectively. Annual sharps injuries incidence rates were 5.1 per 100 full-time equivalent (FTE) nurses and 1.0 per 100 FTE aides. Medical procedures contributing to sharps injuries were injecting medications, administering fingersticks and heelsticks, and drawing blood. Other contributing factors were sharps disposal, contact with waste, and patient handling. Sharps with safety features frequently were not used. Underreporting of sharps injuries to the workplace-based surveillance system was estimated to be about 50%. Conclusions. Sharps injuries and other blood and body fluid exposures are serious hazards for home health care nurses and aides. Improvements in hazard intervention are needed. PMID:19890177

  14. Physiological volume regulation by spermatozoa.

    PubMed

    Yeung, C H; Barfield, J P; Cooper, T G

    2006-05-16

    Maturing spermatozoa passing through the epididymis experience increasing osmolality in the luminal environment and mature cells are stored in fluids hyper-osmotic to serum. When ejaculated into the female tract, they encounter a hypo-osmotic challenge which initiates the process of regulatory volume decrease (RVD). Defects in RVD result in hindrance of mucus penetration in man and failure of utero-tubal passage in mice. Epididymal sperm from the mouse and cynomolgus monkey and ejaculated sperm from man and monkey have been isolated and dispersed in media with osmolalities mimicking those of uterine fluid or cervical mucus. The effects of specific and broad-spectrum ion channel blockers indicate the involvement of separate K+ and Cl- channels as well as organic osmolytes in physiological sperm RVD, with mechanisms developed during epididymal maturation. Western blotting and immuno-cytochemistry identify and localise some of these channels which play a crucial role in fertilisation in vivo and could be targets for post-testicular contraception.

  15. Zeolite-like liquid crystals

    NASA Astrophysics Data System (ADS)

    Poppe, Silvio; Lehmann, Anne; Scholte, Alexander; Prehm, Marko; Zeng, Xiangbing; Ungar, Goran; Tschierske, Carsten

    2015-10-01

    Zeolites represent inorganic solid-state materials with porous structures of fascinating complexity. Recently, significant progress was made by reticular synthesis of related organic solid-state materials, such as metal-organic or covalent organic frameworks. Herein we go a step further and report the first example of a fluid honeycomb mimicking a zeolitic framework. In this unique self-assembled liquid crystalline structure, transverse-lying π-conjugated rod-like molecules form pentagonal channels, encircling larger octagonal channels, a structural motif also found in some zeolites. Additional bundles of coaxial molecules penetrate the centres of the larger channels, unreachable by chains attached to the honeycomb framework. This creates a unique fluid hybrid structure combining positive and negative anisotropies, providing the potential for tuning the directionality of anisotropic optical, electrical and magnetic properties. This work also demonstrates a new approach to complex soft-matter self-assembly, by using frustration between space filling and the entropic penalty of chain extension.

  16. [A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].

    PubMed

    Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N

    1995-04-01

    We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.

  17. Sharp Injury and Exposure to Blood and Body Fluids among Health Care Workers in Health Care Centers of Eastern Ethiopia.

    PubMed

    Alemayehu, T; Worku, A; Assefa, N

    2016-07-01

    Health care workers are facing certain occupational hazards because of sharp injury and exposure to human blood and body fluids as a result of handling wastes. Though much attention is paid for the protection of these workers, the number of exposures and injuries do not show a sign of decline from time to time. To examine the occurrence of sharp injury and exposure to blood and body fluids in health care workers in health care centers in Ethiopia. In a case-control study, a randomly selected sample of 65 health facilities with 391 cases and 429 controls were studied. Data were collected through a self-administered questionnaire. Detailed analysis of exposure among the health care workers was done by logistic regression analysis with generalized estimating equations model to control correlation effects of responses within the cluster of health facilities. The number of health care workers who got sharp injury was 217 (26.5%). 296 (36.1%) had exposure to blood and body fluids. Working at Harari region (adjusted OR 0.44, 95% CI 0.26 to 0.75) and East Hararghea (adjusted OR 0.61, 95% CI 0.40 to 0.94), being male (adjusted OR 0.56, 95% CI 0.44 to 0.91), and a being nurse (adjusted OR 0.188, 95% CI 0.06 to 0.63) were independent risk factors of the exposure. Regardless of the anticipated low self-reporting for exposure status, the number of health care workers reported having sharp injury and exposure to blood and body fluids was high. Such high exposures indicate that health care workers are at high risk of acquiring blood-borne viral infections such as hepatitis B, hepatitis C, and HIV.

  18. Heavy metal and trace element concentrations in blood and follicular fluid affect ART outcome.

    PubMed

    Tolunay, Harun Egemen; Şükür, Yavuz Emre; Ozkavukcu, Sinan; Seval, Mehmet Murat; Ateş, Can; Türksoy, Vugar Ali; Ecemiş, Tolga; Atabekoğlu, Cem Somer; Özmen, Batuhan; Berker, Bülent; Sönmezer, Murat

    2016-03-01

    To assess the effects of heavy metal and trace element concentrations in blood and follicular fluid on assisted reproductive technology cycle outcome. A prospective study was conducted between January 2012 and July 2012 in a university hospital infertility clinic. One hundred and one patients with unexplained infertility who underwent intracytoplasmic sperm injection using GnRH-antagonist protocol were recruited. Concentrations of four toxic metals (Cd, Pb, Hg, As) and three trace elements (Cu, Zn, Fe) were measured both in blood and follicular fluid specimens. Patients were evaluated in two groups; the study group consisted of patients with ongoing pregnancy (n=20) and the reference group consisted of patients experienced assisted reproductive technology failure, miscarriage or biochemical pregnancy (n=81). Demographics and cycle parameters were comparable between the groups except for median number of day 3 Grade A embryos. Statistically significant negative correlations were found between blood Pb levels and number of MII oocytes, implantation, clinical pregnancy and ongoing pregnancy rates. Results of the log binomial regression revealed 2.2% lower risk for ongoing pregnancy for each 1μg/dL higher blood Pb concentration while holding the other variables in the model constant (RR 0.978; 95% CI 0.956-0.998; P=.041). Also, the results revealed 71.9% lower risk for ongoing pregnancy for each 1μg/dL higher follicular fluid Cu concentration while holding the other variables in the model constant (RR 0.288; 95% CI 0.085-0.92; P=.039). Blood concentrations of Pb and follicular fluid concentrations of Cu seem to have significant impacts on assisted reproductive technology cycle outcome. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Goal-Directed Fluid Therapy Based on Stroke Volume Variation in Patients Undergoing Major Spine Surgery in the Prone Position: A Cohort Study.

    PubMed

    Bacchin, Maria Renata; Ceria, Chiara Marta; Giannone, Sandra; Ghisi, Daniela; Stagni, Gaetano; Greggi, Tiziana; Bonarelli, Stefano

    2016-09-15

    A retrospective observational study. The aim of this study was to test whether a goal-directed fluid therapy (GDFT) protocol, based on stroke volume variation (SVV), applied in major spine surgery performed in the prone position, would be effective in reducing peri-operative red blood cells transfusions. Recent literature shows that optimizing perioperative fluid therapy is associated with lower complication rates and faster recovery. Data from 23 patients who underwent posterior spine arthrodesis surgery and whose intraoperative fluid administration were managed with the GDFT protocol were retrospectively collected and compared with data from 23 matched controls who underwent the same surgical procedure in the same timeframe, and who received a liberal intraoperative fluid therapy. Patients in the GDFT group received less units of transfused red blood cells (primary endpoint) in the intra (0 vs. 2.0, P = 0.0 4) and postoperative period (2.0 vs. 4.0, P = 0.003). They also received a lower amount of intraoperative crystalloids, had fewer blood losses, and lower intraoperative peak lactate. In the postoperative period, patients in the GDFT group had fewer pulmonary complications and blood losses from surgical drains, needed less blood product transfusions, had a shorter intensive care unit stay, and a faster return of bowel function. We found no difference in the total length of stay among the two groups. Our study shows that application of a GDFT based on SVV in major spine surgery is feasible and can lead to reduced blood losses and transfusions, better postoperative respiratory performance, shorter ICU stay, and faster return of bowel function. 3.

  20. Magnetic field effect on blood flow of Casson fluid in axisymmetric cylindrical tube: A fractional model

    NASA Astrophysics Data System (ADS)

    Ali, Farhad; Sheikh, Nadeem Ahmad; Khan, Ilyas; Saqib, Muhammad

    2017-02-01

    The effects of magnetohydrodynamics on the blood flow when blood is represented as a Casson fluid, along with magnetic particles in a horizontal cylinder is studied. The flow is due to an oscillating pressure gradient. The Laplace and finite Hankel transforms are used to obtain the closed form solutions of the fractional partial differential equations. Effects of various parameters on the flow of both blood and magnetic particles are shown graphically. The analysis shows that, the model with fractional order derivatives bring a remarkable changes as compared to the ordinary model. The study highlights that applied magnetic field reduces the velocities of both the blood and magnetic particles.

  1. Empirical modelling to predict the refractive index of human blood.

    PubMed

    Yahya, M; Saghir, M Z

    2016-02-21

    Optical techniques used for the measurement of the optical properties of blood are of great interest in clinical diagnostics. Blood analysis is a routine procedure used in medical diagnostics to confirm a patient's condition. Measuring the optical properties of blood is difficult due to the non-homogenous nature of the blood itself. In addition, there is a lot of variation in the refractive indices reported in the literature. These are the reasons that motivated the researchers to develop a mathematical model that can be used to predict the refractive index of human blood as a function of concentration, temperature and wavelength. The experimental measurements were conducted on mimicking phantom hemoglobin samples using the Abbemat Refractometer. The results analysis revealed a linear relationship between the refractive index and concentration as well as temperature, and a non-linear relationship between refractive index and wavelength. These results are in agreement with those found in the literature. In addition, a new formula was developed based on empirical modelling which suggests that temperature and wavelength coefficients be added to the Barer formula. The verification of this correlation confirmed its ability to determine refractive index and/or blood hematocrit values with appropriate clinical accuracy.

  2. Messenger RNA biomarker signatures for forensic body fluid identification revealed by targeted RNA sequencing.

    PubMed

    Hanson, E; Ingold, S; Haas, C; Ballantyne, J

    2018-05-01

    The recovery of a DNA profile from the perpetrator or victim in criminal investigations can provide valuable 'source level' information for investigators. However, a DNA profile does not reveal the circumstances by which biological material was transferred. Some contextual information can be obtained by a determination of the tissue or fluid source of origin of the biological material as it is potentially indicative of some behavioral activity on behalf of the individual that resulted in its transfer from the body. Here, we sought to improve upon established RNA based methods for body fluid identification by developing a targeted multiplexed next generation mRNA sequencing assay comprising a panel of approximately equal sized gene amplicons. The multiplexed biomarker panel includes several highly specific gene targets with the necessary specificity to definitively identify most forensically relevant biological fluids and tissues (blood, semen, saliva, vaginal secretions, menstrual blood and skin). In developing the biomarker panel we evaluated 66 gene targets, with a progressive iteration of testing target combinations that exhibited optimal sensitivity and specificity using a training set of forensically relevant body fluid samples. The current assay comprises 33 targets: 6 blood, 6 semen, 6 saliva, 4 vaginal secretions, 5 menstrual blood and 6 skin markers. We demonstrate the sensitivity and specificity of the assay and the ability to identify body fluids in single source and admixed stains. A 16 sample blind test was carried out by one lab with samples provided by the other participating lab. The blinded lab correctly identified the body fluids present in 15 of the samples with the major component identified in the 16th. Various classification methods are being investigated to permit inference of the body fluid/tissue in dried physiological stains. These include the percentage of reads in a sample that are due to each of the 6 tissues/body fluids tested and inter-sample differential gene expression revealed by agglomerative hierarchical clustering. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Presence and Persistence of Ebola or Marburg Virus in Patients and Survivors: A Rapid Systematic Review.

    PubMed

    Brainard, Julii; Pond, Katherine; Hooper, Lee; Edmunds, Kelly; Hunter, Paul

    2016-02-01

    The 2013-15 Ebola outbreak was unprecedented due to sustained transmission within urban environments and thousands of survivors. In 2014 the World Health Organization stated that there was insufficient evidence to give definitive guidance about which body fluids are infectious and when they pose a risk to humans. We report a rapid systematic review of published evidence on the presence of filoviruses in body fluids of infected people and survivors. Scientific articles were screened for information about filovirus in human body fluids. The aim was to find primary data that suggested high likelihood of actively infectious filovirus in human body fluids (viral RNA). Eligible infections were from Marburg virus (MARV or RAVV) and Zaire, Sudan, Taï Forest and Bundibugyo species of Ebola. Cause of infection had to be laboratory confirmed (in practice either tissue culture or RT-PCR tests), or evidenced by compatible clinical history with subsequent positivity for filovirus antibodies or inflammatory factors. Data were extracted and summarized narratively. 6831 unique articles were found, and after screening, 33 studies were eligible. For most body fluid types there were insufficient patients to draw strong conclusions, and prevalence of positivity was highly variable. Body fluids taken >16 days after onset were usually negative. In the six studies that used both assay methods RT-PCR tests for filovirus RNA gave positive results about 4 times more often than tissue culture. Filovirus was reported in most types of body fluid, but not in every sample from every otherwise confirmed patient. Apart from semen, most non-blood, RT-PCR positive samples are likely to be culture negative and so possibly of low infectious risk. Nevertheless, it is not apparent how relatively infectious many body fluids are during or after illness, even when culture-positive, not least because most test results come from more severe cases. Contact with blood and blood-stained body fluids remains the major risk for disease transmission because of the known high viral loads in blood.

  4. Nrf2 Deficiency Exacerbates Obesity-Induced Oxidative Stress, Neurovascular Dysfunction, Blood-Brain Barrier Disruption, Neuroinflammation, Amyloidogenic Gene Expression, and Cognitive Decline in Mice, Mimicking the Aging Phenotype.

    PubMed

    Tarantini, Stefano; Valcarcel-Ares, M Noa; Yabluchanskiy, Andriy; Tucsek, Zsuzsanna; Hertelendy, Peter; Kiss, Tamas; Gautam, Tripti; Zhang, Xin A; Sonntag, William E; de Cabo, Rafael; Farkas, Eszter; Elliott, Michael H; Kinter, Michael T; Deak, Ferenc; Ungvari, Zoltan; Csiszar, Anna

    2018-06-14

    Obesity has deleterious effects on cognitive function in the elderly adults. In mice, aging exacerbates obesity-induced oxidative stress, microvascular dysfunction, blood-brain barrier (BBB) disruption, and neuroinflammation, which compromise cognitive health. However, the specific mechanisms through which aging and obesity interact to remain elusive. Previously, we have shown that Nrf2 signaling plays a critical role in microvascular resilience to obesity and that aging is associated with progressive Nrf2 dysfunction, promoting microvascular impairment. To test the hypothesis that Nrf2 deficiency exacerbates cerebromicrovascular dysfunction induced by obesity Nrf2+/+ and Nrf2-/-, mice were fed an adipogenic high-fat diet (HFD). Nrf2 deficiency significantly exacerbated HFD-induced oxidative stress and cellular senescence, impairment of neurovascular coupling responses, BBB disruption, and microglia activation, mimicking the aging phenotype. Obesity in Nrf2-/- mice elicited complex alterations in the amyloidogenic gene expression profile, including upregulation of amyloid precursor protein. Nrf2 deficiency and obesity additively reduced long-term potentiation in the CA1 area of the hippocampus. Collectively, Nrf2 dysfunction exacerbates the deleterious effects of obesity, compromising cerebromicrovascular and brain health by impairing neurovascular coupling mechanisms, BBB integrity and synaptic function and promoting neuroinflammation. These results support a possible role for age-related Nrf2 dysfunction in the pathogenesis of vascular cognitive impairment and Alzheimer's disease.

  5. Pro-inflammatory activity in rats of thiocyanate, a metabolite of the hydrocyanic acid inhaled from tobacco smoke.

    PubMed

    Whitehouse, Michael Wellesley; Jones, Mark

    2009-10-01

    To seek a mechanism linking tobacco smoking with the increased incidence and severity of rheumatoid arthritis, deduced from many retrospective surveys, by studying arthritis/fibrosis development in rats. Rats (>300) received low levels of sodium/potassium thiocyanate (10 or 25 mmol/l) in their drinking water to raise their blood thiocyanate levels, mimicking the elevated levels of blood, salivary and urinary thiocyanate found in smokers. Thiocyanate supplements increased the severity of experimental arthritis induced by tailbase injection of (1) Freund's complete adjuvants (mycobacteria plus various adjuvant-active oils), (2) collagen type-II with Freund's incomplete adjuvant (no mycobacteria), (3) the synthetic lipid amine, avridine in an oil and (4) the natural hydrocarbons squalene (C(30)H(50)) and pristane (C(19)H(40)). This pro-arthritic effect was independent of sex, rat strain or changing diet and housing facilities. Thiocyanate supplements also amplified the acute/persisting inflammatory responses to paw injections of pristane, zymosan and microcrystalline hydroxyapatite. Iodide salts also mimicked some of these effects of thiocyanate. Thiocyanate, a detoxication product of HCN present in tobacco smoke, increased (or even induced) inflammatory responses to several agents causing arthritis or fibrotic inflammation in rats. It, therefore, can act as a co-arthritigen, or 'virulence factor' and could be a therapeutic target to reduce arthritis expression and morbidity.

  6. Plasmodium coatneyi in Rhesus Macaques Replicates the Multisystemic Dysfunction of Severe Malaria in Humans

    PubMed Central

    Cabrera-Mora, Monica; Garcia, AnaPatricia; Orkin, Jack; Strobert, Elizabeth; Barnwell, John W.; Galinski, Mary R.

    2013-01-01

    Severe malaria, a leading cause of mortality among children and nonimmune adults, is a multisystemic disorder characterized by complex clinical syndromes that are mechanistically poorly understood. The interplay of various parasite and host factors is critical in the pathophysiology of severe malaria. However, knowledge regarding the pathophysiological mechanisms and pathways leading to the multisystemic disorders of severe malaria in humans is limited. Here, we systematically investigate infections with Plasmodium coatneyi, a simian malaria parasite that closely mimics the biological characteristics of P. falciparum, and develop baseline data and protocols for studying erythrocyte turnover and severe malaria in greater depth. We show that rhesus macaques (Macaca mulatta) experimentally infected with P. coatneyi develop anemia, coagulopathy, and renal and metabolic dysfunction. The clinical course of acute infections required suppressive antimalaria chemotherapy, fluid support, and whole-blood transfusion, mimicking the standard of care for the management of severe malaria cases in humans. Subsequent infections in the same animals progressed with a mild illness in comparison, suggesting that immunity played a role in reducing the severity of the disease. Our results demonstrate that P. coatneyi infection in rhesus macaques can serve as a highly relevant model to investigate the physiological pathways and molecular mechanisms of malaria pathogenesis in naïve and immune individuals. Together with high-throughput postgenomic technologies, such investigations hold promise for the identification of new clinical interventions and adjunctive therapies. PMID:23509137

  7. The use of micro-/milli-fluidics to better understand the mechanisms behind deep venous thrombosis

    NASA Astrophysics Data System (ADS)

    Schofield, Zoe; Alexiadis, Alessio; Brill, Alexander; Nash, Gerard; Vigolo, Daniele

    2016-11-01

    Deep venous thrombosis (DVT) is a dangerous and painful condition in which blood clots form in deep veins (e.g., femoral vein). If these clots become unstable and detach from the thrombus they can be delivered to the lungs resulting in a life threatening complication called pulmonary embolism (PE). Mechanisms of clot development in veins remain unclear but researchers suspect that the specific flow patterns in veins, especially around the valve flaps, play a fundamental role. Here we show how it is now possible to mimic the current murine model by developing micro-/milli-fluidic experiments. We exploited a novel detection technique, ghost particle velocimetry (GPV), to analyse the velocity profiles for various geometries. These vary from regular microfluidics with a rectangular cross section with a range of geometries (mimicking the presence of side and back branches in veins, closed side branch and flexible valves) to a more accurate venous representation with a 3D cylindrical geometry obtained by 3D printing. In addition to the GPV experiments, we analysed the flow field developing in these geometries by using computational fluid dynamic simulations to develop a better understanding of the mechanisms behind DVT. ZS gratefully acknowledges financial support from the EPSRC through a studentship from the Sci-Phy-4-Health Centre for Doctoral Training (EP/L016346/1).

  8. Peripheral Interventions Enhancing Brain Glutamate Homeostasis Relieve Amyloid β- and TNFα- Mediated Synaptic Plasticity Disruption in the Rat Hippocampus.

    PubMed

    Zhang, Dainan; Mably, Alexandra J; Walsh, Dominic M; Rowan, Michael J

    2017-07-01

    Dysregulation of glutamate homeostasis in the interstitial fluid of the brain is strongly implicated in causing synaptic dysfunction in many neurological and psychiatric illnesses. In the case of Alzheimer's disease (AD), amyloid β (Aβ)-mediated disruption of synaptic plasticity and memory can be alleviated by interventions that directly remove glutamate or block certain glutamate receptors. An alternative strategy is to facilitate the removal of excess glutamate from the nervous system by activating peripheral glutamate clearance systems. One such blood-based system, glutamate oxaloacetate transaminase (GOT), is activated by oxaloacetate, which acts as a co-substrate. We report here that synthetic and AD brain-derived Aβ-mediated inhibition of synaptic long-term potentiation in the hippocampus is alleviated by oxaloacetate. Moreover the effect of oxaloacetate was GOT-dependent. The disruptive effects of a general inhibitor of excitatory amino acid transport or TNFα, a pro-inflammatory mediator of Aβ action, were also reversed by oxaloacetate. Furthermore, another intervention that increases peripheral glutamate clearance, peritoneal dialysis, mimicked the beneficial effect of oxaloacetate. These findings lend support to the promotion of the peripheral clearance of glutamate as a means to alleviate synaptic dysfunction that is caused by impaired glutamate homeostasis in the brain. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  9. Nanoporous Membrane Immunosensor

    DTIC Science & Technology

    2000-01-01

    but not intended to be limited to blood, saliva, ocular lens fluid, cerebral spinal fluid, sweat, urine, milk, ascites fluid, mucous, synovial fluid...such as rubella-IgG and rubella-IgM; antibodies to toxoplasmosis , such as toxoplasmosis IgG(Toxo-IgG) and toxoplasmosis IgM (Toxo-IgM); testosterone

  10. Partitioned fluid-solid coupling for cardiovascular blood flow: left-ventricular fluid mechanics.

    PubMed

    Krittian, Sebastian; Janoske, Uwe; Oertel, Herbert; Böhlke, Thomas

    2010-04-01

    We present a 3D code-coupling approach which has been specialized towards cardiovascular blood flow. For the first time, the prescribed geometry movement of the cardiovascular flow model KaHMo (Karlsruhe Heart Model) has been replaced by a myocardial composite model. Deformation is driven by fluid forces and myocardial response, i.e., both its contractile and constitutive behavior. Whereas the arbitrary Lagrangian-Eulerian formulation (ALE) of the Navier-Stokes equations is discretized by finite volumes (FVM), the solid mechanical finite elasticity equations are discretized by a finite element (FEM) approach. Taking advantage of specialized numerical solution strategies for non-matching fluid and solid domain meshes, an iterative data-exchange guarantees the interface equilibrium of the underlying governing equations. The focus of this work is on left-ventricular fluid-structure interaction based on patient-specific magnetic resonance imaging datasets. Multi-physical phenomena are described by temporal visualization and characteristic FSI numbers. The results gained show flow patterns that are in good agreement with previous observations. A deeper understanding of cavity deformation, blood flow, and their vital interaction can help to improve surgical treatment and clinical therapy planning.

  11. Advanced statistical analysis of Raman spectroscopic data for the identification of body fluid traces: semen and blood mixtures.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-10-10

    Conventional confirmatory biochemical tests used in the forensic analysis of body fluid traces found at a crime scene are destructive and not universal. Recently, we reported on the application of near-infrared (NIR) Raman microspectroscopy for non-destructive confirmatory identification of pure blood, saliva, semen, vaginal fluid and sweat. Here we expand the method to include dry mixtures of semen and blood. A classification algorithm was developed for differentiating pure body fluids and their mixtures. The classification methodology is based on an effective combination of Support Vector Machine (SVM) regression (data selection) and SVM Discriminant Analysis of preprocessed experimental Raman spectra collected using an automatic mapping of the sample. This extensive cross-validation of the obtained results demonstrated that the detection limit of the minor contributor is as low as a few percent. The developed methodology can be further expanded to any binary mixture of complex solutions, including but not limited to mixtures of other body fluids. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. A microfluidic circulatory system integrated with capillary-assisted pressure sensors.

    PubMed

    Chen, Yangfan; Chan, Ho Nam; Michael, Sean A; Shen, Yusheng; Chen, Yin; Tian, Qian; Huang, Lu; Wu, Hongkai

    2017-02-14

    The human circulatory system comprises a complex network of blood vessels interconnecting biologically relevant organs and a heart driving blood recirculation throughout this system. Recreating this system in vitro would act as a bridge between organ-on-a-chip and "body-on-a-chip" and advance the development of in vitro models. Here, we present a microfluidic circulatory system integrated with an on-chip pressure sensor to closely mimic human systemic circulation in vitro. A cardiac-like on-chip pumping system is incorporated in the device. It consists of four pumping units and passive check valves, which mimic the four heart chambers and heart valves, respectively. Each pumping unit is independently controlled with adjustable pressure and pump rate, enabling users to control the mimicked blood pressure and heartbeat rate within the device. A check valve is located downstream of each pumping unit to prevent backward leakage. Pulsatile and unidirectional flow can be generated to recirculate within the device by programming the four pumping units. We also report an on-chip capillary-assisted pressure sensor to monitor the pressure inside the device. One end of the capillary was placed in the measurement region, while the other end was sealed. Time-dependent pressure changes were measured by recording the movement of the liquid-gas interface in the capillary and calculating the pressure using the ideal gas law. The sensor covered the physiologically relevant blood pressure range found in humans (0-142.5 mmHg) and could respond to 0.2 s actuation time. With the aid of the sensor, the pressure inside the device could be adjusted to the desired range. As a proof of concept, human normal left ventricular and arterial pressure profiles were mimicked inside this device. Human umbilical vein endothelial cells (HUVECs) were cultured on chip and cells can respond to mechanical forces generated by arterial-like flow patterns.

  13. Dementia

    MedlinePlus

    ... Blood ammonia levels Blood chemistry ( chem-20 ) Blood gas analysis Cerebrospinal fluid (CSF) analysis Drug or alcohol ... these drugs may be small Control problems with behavior, such as loss of judgment or confusion Someone ...

  14. Comparison of the effects of albumin 5%, hydroxyethyl starch 130/0.4 6%, and Ringer's lactate on blood loss and coagulation after cardiac surgery.

    PubMed

    Skhirtladze, K; Base, E M; Lassnigg, A; Kaider, A; Linke, S; Dworschak, M; Hiesmayr, M J

    2014-02-01

    Infusion of 5% human albumin (HA) and 6% hydroxyethyl starch 130/0.4 (HES) during cardiac surgery expand circulating volume to a greater extent than crystalloids and would be suitable for a restrictive fluid therapy regimen. However, HA and HES may affect blood coagulation and could contribute to increased transfusion requirements. We randomly assigned 240 patients undergoing elective cardiac surgery to receive up to 50 ml kg(-1) day(-1) of either HA, HES, or Ringer's lactate (RL) as the main infusion fluid perioperatively. Study solutions were supplied in identical bottles dressed in opaque covers. The primary outcome was chest tube drainage over 24 h. Blood transfusions, thromboelastometry variables, perioperative fluid balance, renal function, mortality, intensive care unit, and hospital stay were also assessed. The median cumulative blood loss was not different between the groups (HA: 835, HES: 700, and RL: 670 ml). However, 35% of RL patients required blood products, compared with 62% (HA) and 64% (HES group; P=0.0003). Significantly, more study solution had to be administered in the RL group compared with the colloid groups. Total perioperative fluid balance was least positive in the HA group [6.2 (2.5) litre] compared with the HES [7.4 (3.0) litre] and RL [8.3 (2.8) litre] groups (P<0.0001). Both colloids affected clot formation and clot strength and caused slight increases in serum creatinine. Despite equal blood loss from chest drains, both colloids interfered with blood coagulation and produced greater haemodilution, which was associated with more transfusion of blood products compared with crystalloid use only.

  15. Borrelia Lymphocytoma Mimicking Butterfly Rash in a Pediatric Patient.

    PubMed

    Llamas-Velasco, Mar; Paredes, Bruno Emilio

    2018-03-01

    A 5-year-old girl presented with a facial butterfly rash that persisted for 5 months without arthralgia, fever, malaise, photosensitivity, or other symptoms. Lupus erythematosus was clinically suspected. All blood tests were negative or within normal values. Skin biopsy showed a dense nodular superficial and deep inflammatory infiltrate of lymphocytes that reaches subcutaneous tissue. The most striking histopathological finding was plasma cells with some perifollicular accentuation. Borrelia polymerase chain reaction assay of the tissue was positive, and we made the diagnoses of borrelia lymphocytoma mimicking butterfly rash of lupus erythematosus. The lesions disappeared with amoxicillin followed by cefuroxime for 28 days. In children, a variety of diseases including lupus erythematous may lead to a butterfly rash that is usually short lasting and commonly associated with systemic symptoms. Borreliosis may be related with long-lasting facial erythema in children and may mimic lupus and present high titers of antinuclear antibodies. In any case, borrelial lymphocytoma has not been previously reported as a cause of butterfly rash, thus mimicking acute lupus in a child, as in our case. From a histopathological point of view, the presence of plasma cells in a pseudolymphomatous infiltrate is a clue for the right diagnosis. Therefore, we suggest that borrelia serology should be done in children with butterfly rash lasting more than a month and empirical antibiotic treatment should be tried even in cases with negative serology.

  16. Drag penalty due to the asperities in the substrate of super-hydrophobic and liquid infused surfaces

    NASA Astrophysics Data System (ADS)

    Garcia Cartagena, Edgardo J.; Arenas, Isnardo; Leonardi, Stefano

    2017-11-01

    Direct numerical simulations of two superposed fluids in a turbulent channel with a textured surface made of pinnacles of random height have been performed. The viscosity ratio between the two fluids are N =μo /μi = 50 (μo and μi are the viscosities of outer and inner fluid respectively) mimicking a super-hydrophobic surface (water over air) and N=2.5 (water over heptane) resembling a liquid infused surface. Two set of simulations have been performed varying the Reynolds number, Reτ = 180 and Reτ = 390 . The interface between the two fluids is flat simulating infinite surface tension. The position of the interface between the two fluids has been varied in the vertical direction from the base of the substrate (what would be a rough wall) to the highest point of the roughness. Drag reduction is very sensitive to the position of the interface between the two fluids. Asperities above the interface induce a large form drag and diminish considerably the drag reduction. When the mean height of the surface measured from the interface in the outer fluid is greater than one wall unit, k+ > 1 , the drag increases with respect to a smooth wall. Present results provide a guideline to the accuracy required in manufacturing super-hydrophobic and liquid infused surfaces. This work was supported under ONR MURI Grants N00014-12-0875 and N00014-12- 1-0962, Program Manager Dr. Ki-Han Kim. Numerical simulations were performed on the Texas Advanced Computer Center.

  17. Acute Effects of Prostaglandin E1 and E2 on Vascular Reactivity and Blood Flow in situ in the Chick Chorioallantoic Membrane

    PubMed Central

    Fay, K.; Dunn, B.E.; Gruenloh, S.K.; Narayanan, J.; Jacobs, E.R.; Medhora, M.

    2013-01-01

    1. The chick chorioallantoic membrane (CAM) subserves gas exchange in the developing embryo and shell-less culture affords a unique opportunity for direct observations over time of individual blood vessels to pharmacologic interventions. We tested a number of lipids including prostaglandins PGE1&2 for vascular effects and signaling in the CAM. Application of PGE1&2 induced a decrease in the diameter of large blood vessels and a concentration-dependent, localized, reversible loss of blood flow through small vessels. The loss of flow was also mimicked by misoprostol, an agonist for 3 of 4 known PGE receptors, EP2-4, and by U46619, a thromboxane mimetic. Selective receptor antagonists for EP3 and thromboxane each partially blocked the response. This is a first report of the effects of prostaglandins on vasoreactivity in the CAM. Our model allows the unique ability to examine simultaneous responses of large and small vessels in real time and in vivo. PMID:22858445

  18. Traumatic Extra-capsular and Intra-capsular Floating Fat: Fat-fluid Levels of the Knee Revisited

    PubMed Central

    Davis, Derik L; Vachhani, Prasann

    2015-01-01

    Floating fat is a sign of acute bone injury at the knee following trauma. The goal of this article is to review the etiology, patterns, and mimickers of extra-capsular and intra-capsular floating fat, with the major emphasis on knee trauma in the acute setting. We will discuss the spectrum of multimodal imaging findings for rare presentations of extra-capsular floating fat, and contrast these with common and atypical forms of intra-capsular lipohemarthrosis, as an aid to the assessment of acute bone trauma at the knee. PMID:26713176

  19. [IL-1beta and PGE2 production in whole blood and gingival fluid in women with periodontitis and preterm low birth weight].

    PubMed

    Konopka, Tomasz; Rutkowska, Monika; Hirnle, Lidia; Kopeć, Wacław

    2004-05-01

    The aim of the investigation was to evaluate of IL-1beta and PGE2 concentrations in gingival fluid, whole blood as well as IL-1beta, PGE2 production after Escherichia coli lipopolysaccharide stimulation in whole blood in women with preterm low birth weight (PLBW), as compared to the control group. A case-control study of 88 postpartum women aged 17 to 39 was performed. The case group consisted of 52 women with PLBW and the control group consisted of 36 women giving birth in time. Concentration of inflammatory mediators in gingival fluid, blood serum and IL-1beta, PGE2 production in whole blood after bacterial lipopolysaccharide stimulation were determined by means of immunoenzymatic method. The levels of IL-1beta and PGE2 in gingival fluid were significantly higher in all PLBW mothers (also PLBW primiparous) than in the control group. In addition in the primiparous with PLBW group significantly higher PGE2 concentration in blood serum was found compared to the primiparous controls. There were no significant differences between women with PLBW and the controls together with a significantly higher production of IL-1beta and PGE2 in whole blood after LPS stimulation in women with periodontitis and gingivitis compared to subjects with healthy periodontium. Such findings suggest that inflammatory mediator synthesis is mainly result of specific cells exposition to bacterial products. Therefore it seems that more frequent occurrence of the phenotype of hyperactive cells that synthesise these mediators is not responsible for PLBW.

  20. Interpretation of Oral Fluid Tests for Drugs of Abuse

    PubMed Central

    CONE, EDWARD J.; HUESTIS, MARILYN A.

    2009-01-01

    Oral fluid testing for drugs of abuse offers significant advantages over urine as a test matrix. Collection can be performed under direct observation with reduced risk of adulteration and substitution. Drugs generally appear in oral fluid by passive diffusion from blood, but also may be deposited in the oral cavity during oral, smoked, and intranasal administration. Drug metabolites also can be detected in oral fluid. Unlike urine testing, there may be a close correspondence between drug and metabolite concentrations in oral fluid and in blood. Interpretation of oral fluid results for drugs of abuse should be an iterative process whereby one considers the test results in the context of program requirements and a broad scientific knowledge of the many factors involved in determining test outcome. This review delineates many of the chemical and metabolic processes involved in the disposition of drugs and metabolites in oral fluid that are important to the appropriate interpretation of oral fluid tests. Chemical, metabolic, kinetic, and analytic parameters are summarized for selected drugs of abuse, and general guidelines are offered for understanding the significance of oral fluid tests. PMID:17332074

  1. Mathematical modeling of fluid-electrolyte alterations during weightlessness

    NASA Technical Reports Server (NTRS)

    Leonard, J. I.

    1984-01-01

    Fluid electrolyte metabolism and renal endocrine control as it pertains to adaptation to weightlessness were studied. The mathematical models that have been particularly useful are discussed. However, the focus of the report is on the physiological meaning of the computer studies. A discussion of the major ground based analogs of weightlessness are included; for example, head down tilt, water immersion, and bed rest, and a comparison of findings. Several important zero g phenomena are described, including acute fluid volume regulation, blood volume regulation, circulatory changes, longer term fluid electrolyte adaptations, hormonal regulation, and body composition changes. Hypotheses are offered to explain the major findings in each area and these are integrated into a larger hypothesis of space flight adaptation. A conceptual foundation for fluid electrolyte metabolism, blood volume regulation, and cardiovascular regulation is reported.

  2. On the suitability of refractometry for the analysis of glucose in blood-derived fluids.

    PubMed

    Zirk, K; Poetzschke, H

    2004-07-01

    Refractometry is the determination of the optical refractive index of a substance or a mixture of substances. It is a very sensitive method for the detection and quantification of dissolved analytes, but it is incapable of distinguishing between different analytes. The aim of this investigation was to determine the principle suitability of refractometry for the quantification of glucose (blood sugar) in blood and various blood fluids which can readily be obtained for medical diagnosis, in particular blood plasma, blood serum, and their ultrafiltrates. After the oral intake of freshly dissolved alpha-glucose, the in vivo blood contents of the alpha and beta anomers of glucose were found to be in an at least approximate equilibrium at all times. This observation is a prerequisite for a refractometrical determination of glucose due to the fact that both molecule forms have different refractive index increments. An assessment of the glucose content in untreated blood fluids was not possible, since no suitable relationship to the refractive index was found, most probably due to the influence of the many other substances present in blood on this parameter. However, after removal of certain macromolecules by ultrafiltration, value pairs showed a high level of correlation, providing the nominal molecular weight limit (cut-off) of the ultrafilter used possessed a maximum of 300 kDa. Besides macromolecules, the osmolality of the fluids undergoing measurement also proved to be a considerable interfering factor, particularly when values were outside the normal physiological range between 285 and 293 mmol/L. If a clinical application of this method is to be contemplated it is imperative (1) that blood cells are separated and removed, (2) that macromolecules present in plasma or serum are removed, e.g. by ultrafiltration, and (3) that beyond the results presented the influence of all small molecules other than glucose on the overall refractive index be determined and included in the calculation of analysis results.

  3. Effect of non-Newtonian viscosity on the fluid-dynamic characteristics in stenotic vessels

    NASA Astrophysics Data System (ADS)

    Huh, Hyung Kyu; Ha, Hojin; Lee, Sang Joon

    2015-08-01

    Although blood is known to have shear-thinning and viscoelastic properties, the effects of such properties on the hemodynamic characteristics in various vascular environments are not fully understood yet. For a quantitative hemodynamic analysis, the refractive index of a transparent blood analogue needs to be matched with that of the flowing conduit in order to minimize the errors according to the distortion of the light. In this study, three refractive index-matched blood analogue fluids with different viscosities are prepared—one Newtonian and two non-Newtonian analogues—which correspond to healthy blood with 45 % hematocrit (i.e., normal non-Newtonian) and obese blood with higher viscosity (i.e., abnormal non-Newtonian). The effects of the non-Newtonian rheological properties of the blood analogues on the hemodynamic characteristics in the post-stenosis region of an axisymmetric stenosis model are experimentally investigated using particle image velocimetry velocity field measurement technique and pathline flow visualization. As a result, the centerline jet flow from the stenosis apex is suppressed by the shear-thinning feature of the blood analogues when the Reynolds number is smaller than 500. The lengths of the recirculation zone for abnormal and normal non-Newtonian blood analogues are 3.67 and 1.72 times shorter than that for the Newtonian analogue at Reynolds numbers smaller than 200. The Reynolds number of the transition from laminar to turbulent flow for all blood analogues increases as the shear-thinning feature increases, and the maximum wall shear stresses in non-Newtonian fluids are five times greater than those in Newtonian fluids. However, the shear-thinning effect on the hemodynamic characteristics is not significant at Reynolds numbers higher than 1000. The findings of this study on refractive index-matched non-Newtonian blood analogues can be utilized in other in vitro experiments, where non-Newtonian features dominantly affect the flow characteristics.

  4. Detection of Classical swine fever virus infection by individual oral fluid of pigs following experimental inoculation.

    PubMed

    Petrini, Stefano; Pierini, Ilaria; Giammarioli, Monica; Feliziani, Francesco; De Mia, Gian Mario

    2017-03-01

    We evaluated the use of oral fluid as an alternative to serum samples for Classical swine fever virus (CSFV) detection. Individual oral fluid and serum samples were collected at different times post-infection from pigs that were experimentally inoculated with CSFV Alfort 187 strain. We found no evidence of CSFV neutralizing antibodies in swine oral fluid samples under our experimental conditions. In contrast, real-time reverse transcription-polymerase chain reaction could detect CSFV nucleic acid from the oral fluid as early as 8 d postinfection, which also coincided with the time of initial detection in blood samples. The probability of CSFV detection in oral fluid was identical or even higher than in the corresponding blood sample. Our results support the feasibility of using this sampling method for CSFV genome detection, which may represent an additional cost-effective tool for CSF control.

  5. Effect of lower-body positive pressure on postural fluid shifts in men

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.; Kravik, S. E.; Greenleaf, J. E.

    1988-01-01

    The effect of the lower-body positive pressure (LBPP) on the orthostatic fluid and protein shifts were investigated in five men during combined tilt-table/antigravity suit inflation and deflation experiments. Changes in the mass densities of venous blood and plasma were measured and the values were used to calculate the densities of erythrocytes, whole-body blood, and shifted fluid. It was found that the application of 60 mm Hg LBPP during 60-deg head-up tilt prevented about half of the postural hemoconcentration occurring during passive head-up tilt.

  6. Cytomegalovirus infection in immunocompetent wheezy infants: the diagnostic value of CMV PCR in bronchoalveolar lavage fluid.

    PubMed

    Cinel, G; Pekcan, S; Ozçelik, U; Alp, A; Yalçın, E; Doğru Ersöz, D; Kiper, N

    2014-08-01

    Cytomegalovirus (CMV) pneumonitis in immunocompetent hosts is uncommon but is being recognized more frequently, particularly when presenting as severe viral pneumonia. The objective of this study was to examine lower respiratory tract CMV infection in immunocompetent wheezy infants, based on polymerase chain reaction (PCR) in bronchoalveolar lavage (BAL) fluid, to compare CMV PCR results in BAL and in blood samples and to evaluate the benefits of antiviral ganciclovir therapy in these patients. Retrospective review of the records of patients referred to our tertiary care hospital between January 2000 and July 2010 who had unexplained persistent wheezing and underwent fibreoptic flexible bronchoscopy (FFB). Fibreoptic flexible bronchoscopy was applied to 102 infants with persistent wheezing and diffuse interstitial infiltration on radiological investigations; so CMV PCR in BAL fluid was performed. CMV PCR in BAL fluid was positive in 51 patients. Retrospectively, we had access to the files of 25 of these patients. The mean CMV PCR in BAL fluid was 334 840 copies/mL. Only eight patients had CMV PCR positivity in their blood samples (mean: 2026·3 copies/mL). There was not a relationship between BAL and blood CMV PCR values based on Spearman's correlation analysis (r = -0·008). Fourteen patients had severe respiratory symptoms and received ganciclovir therapy. Twelve of them fully recovered. Bronchoalveolar lavage fluid CMV PCR was superior to blood CMV PCR in diagnosing lower respiratory tract infections caused by CMV in immunocompetent infants. Ganciclovir therapy may be effective in selected immunocompetent wheezy infants with CMV PCR positivity in BAL fluid. © 2014 John Wiley & Sons Ltd.

  7. A pilot study evaluating protein abundance in pressure ulcer fluid from people with and without spinal cord injury

    PubMed Central

    Edsberg, Laura E.; Wyffels, Jennifer T.; Ogrin, Rajna; Craven, B. Catharine; Houghton, Pamela

    2015-01-01

    Objective To determine whether the biochemistry of chronic pressure ulcers differs between patients with and without chronic spinal cord injury (SCI) through measurement and comparison of the concentration of wound fluid inflammatory mediators, growth factors, cytokines, acute phase proteins, and proteases. Design Survey. Setting Tertiary spinal cord rehabilitation center and skilled nursing facilities. Participants Twenty-nine subjects with SCI and nine subjects without SCI (>18 years) with at least one chronic pressure ulcer Stage II, III, or IV were enrolled. Outcome measures Total protein and 22 target analyte concentrations including inflammatory mediators, growth factors, cytokines, acute phase proteins, and proteases were quantified in the wound fluid and blood serum samples. Blood samples were tested for complete blood count, albumin, hemoglobin A1c, total iron binding capacity, iron, percent (%) saturation, C-reactive protein, and erythrocyte sedimentation rate. Results Wound fluid concentrations were significantly different between subjects with SCI and subjects without SCI for total protein concentration and nine analytes, MMP-9, S100A12, S100A8, S100A9, FGF2, IL-1b, TIMP-1, TIMP-2, and TGF-b1. Subjects without SCI had higher values for all significantly different analytes measured in wound fluid except FGF2, TGF-b1, and wound fluid total protein. Subject-matched circulating levels of analytes and the standardized local concentration of the same proteins in the wound fluid were weakly or not correlated. Conclusions The biochemical profile of chronic pressure ulcers is different between SCI and non-SCI populations. These differences should be considered when selecting treatment options. Systemic blood serum properties may not represent the local wound environment. PMID:24968005

  8. The role of synovial fluid analysis in the detection of periprosthetic hip and knee infections: a systematic review and meta-analysis.

    PubMed

    De Fine, Marcello; Giavaresi, Gianluca; Fini, Milena; Illuminati, Andrea; Terrando, Silvio; Pignatti, Giovanni

    2018-05-01

    This study tried to ascertain (1) the accuracy of synovial fluid white blood cell count and polymorphonucleate percentage in the diagnosis of periprosthetic hip and knee infections, (2) which test yielded superior test performance, and (3) the influence on diagnostic accuracy of study characteristics such as patient number, study design, study level, anatomic site, and threshold value. A systematic search was conducted including papers assessing more effective cutoffs for synovial fluid tests, having comparative design, evaluating an exclusive cohort of hip or knee prostheses, including a clear definition of infected cases, and reporting sufficient data for the calculation of true-positive, false-positive, false-negative, and true-negative. A total of 375 articles were collected and, given the inclusion criteria, ten manuscripts were included. These studies assessed 1155 hip prostheses (276 infected cases) and 1235 knee prostheses (401 infected cases). The specificity of synovial fluid white blood cell count was significantly increased by using the threshold value ≥ 3000 cell/μL (p = 0.006); the sensitivity of polymorphonucleate percentage was significantly higher in detecting knee infections (p = 0.034). Both tests had a high specificity and sensitivity in detecting periprosthetic joint infections, and no clear superiority of one over the other existed. Furthermore, cutoff and anatomic site significantly influenced synovial fluid white blood cell count and polymorphonucleate percentage, respectively. Synovial fluid analysis is adequate in differentiating patients with periprosthetic hip and knee infections. Our data confirms international guidelines suggesting the use of 3000 cell/μL as cutoff threshold for synovial fluid white blood cell count. Since an anatomic site effect has been demonstrated, the goal of future studies will be to identify different cutoffs for hip and knee prostheses.

  9. Calculation and analysis of velocity and viscous drag in an artery with a periodic pressure gradient

    NASA Astrophysics Data System (ADS)

    Alizadeh, M.; Seyedpour, S. M.; Mozafari, V.; Babazadeh, Shayan S.

    2012-07-01

    Blood as a fluid that human and other living creatures are dependent on has been always considered by scientists and researchers. Any changes in blood pressure and its normal velocity can be a sign of a disease. Whatever significant in blood fluid's mechanics is Constitutive equations and finding some relations for analysis and description of drag, velocity and periodic blood pressure in vessels. In this paper, by considering available experimental quantities, for blood pressure and velocity in periodic time of a thigh artery of a living dog, at first it is written into Fourier series, then by solving Navier-Stokes equations, a relation for curve drawing of vessel blood pressure with rigid wall is obtained. Likewise in another part of this paper, vessel wall is taken in to consideration that vessel wall is elastic and its pressure and velocity are written into complex Fourier series. In this case, by solving Navier-Stokes equations, some relations for blood velocity, viscous drag on vessel wall and blood pressure are obtained. In this study by noting that vessel diameter is almost is large (3.7 mm), and blood is considered as a Newtonian fluid. Finally, available experimental quantities of pressure with obtained curve of solving Navier-Stokes equations are compared. In blood analysis in rigid vessel, existence of 48% variance in pressure curve systole peak caused vessel blood flow analysis with elastic wall, results in new relations for blood flow description. The Resultant curve is obtained from new relations holding 10% variance in systole peak.

  10. Effect and Outcome of Intraoperative Fluid Restriction in Living Liver Donor Hepatectomy.

    PubMed

    Wang, Chih-Hsien; Cheng, Kwok-Wai; Chen, Chao-Long; Wu, Shao-Chun; Shih, Tsung-Hsiao; Yang, Sheng-Chun; Lee, Ying-En; Jawan, Bruno; Huang, Chiu-En; Juang, Sin-Ei; Huang, Chia-Jung

    2017-11-10

    BACKGROUND The purpose of this study was to evaluate the effect and outcome of intraoperative fluid restriction in living liver donor hepatectomy, regarding changes in intraoperative CVP levels, blood loss, and postoperative renal function. MATERIAL AND METHODS The charts of 167 patients were reviewed and analyzed retrospectively. Intraoperative central venous pressure levels, blood loss, fluids infused, and urine output per hour, before and after the liver allograft procurement, were calculated. Perioperative renal functions were also analyzed. RESULTS Fluid infused before and after liver allograft procurement was 3.21±1.5 and 9.0±3.9 mL/Kg/h and urine output was 1.5±0.7 and 1.8±1.4 mL/Kg/h, respectively. Intraoperative estimated blood loss was 91.3±78.9 mL. No patients required blood transfusion. Their preoperative and postoperative hemoglobin were 12.3±2.7 and 11.7±1.7 g/dL. CVP levels decreased gradually from 10.4±3.0 to a low of 8.1±1.9 mmHg at the time of transection of the liver parenchyma. Renal functions were not significantly affected based on the determination of BUN and creatinine levels. CONCLUSIONS The methods used to lower CVP are moderate and slow, with 2 main goals achieved: minimal blood loss (91.3±78.9 ml) and no blood transfusion. Furthermore, it did not have any negative effect on renal function.

  11. The application of silicon sol-gel technology to forensic blood substitute development: Mimicking aspects of whole human blood rheology.

    PubMed

    Stotesbury, Theresa; Illes, Mike; Wilson, Paul; Vreugdenhil, Andrew J

    2017-01-01

    Solution-gelation chemistry has promising applications in forensic synthetic blood substitute development. This research offers a silicon-based sol-gel approach to creating stable materials that share similar rheological properties to that of whole human blood samples. Room temperature, high water content, silicon sol-gels were created using the organosilane precursors 3-glycidoxypropyltrimethoxysilane and tetraethylorthosilicate along with various concentrations of filler and pigment. Shear-thinning non-Newtonian properties were observed within most formulations of the presented materials. The effects of colloidal concentration, temperature, age and filler addition on the viscosity of the sol-gels were investigated. SEM-EDS analysis was used to identify the behavior of the fillers within the film and support their inclusion for basic bloodstain pattern simulation. A final proposed candidate sol-gel was assessed using a previously reported passive drip simulation test on a hard, dry surface and passed. This works represents encouraging development in providing safe material alternatives to using whole human blood for forensic training and research. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. Painting blood vessels and atherosclerotic plaques with an adhesive drug depot

    PubMed Central

    Kastrup, Christian J.; Nahrendorf, Matthias; Figueiredo, Jose Luiz; Lee, Haeshin; Kambhampati, Swetha; Lee, Timothy; Cho, Seung-Woo; Gorbatov, Rostic; Iwamoto, Yoshiko; Dang, Tram T.; Dutta, Partha; Yeon, Ju Hun; Cheng, Hao; Pritchard, Christopher D.; Vegas, Arturo J.; Siegel, Cory D.; MacDougall, Samantha; Okonkwo, Michael; Thai, Anh; Stone, James R.; Coury, Arthur J.; Weissleder, Ralph; Langer, Robert; Anderson, Daniel G.

    2012-01-01

    The treatment of diseased vasculature remains challenging, in part because of the difficulty in implanting drug-eluting devices without subjecting vessels to damaging mechanical forces. Implanting materials using adhesive forces could overcome this challenge, but materials have previously not been shown to durably adhere to intact endothelium under blood flow. Marine mussels secrete strong underwater adhesives that have been mimicked in synthetic systems. Here we develop a drug-eluting bioadhesive gel that can be locally and durably glued onto the inside surface of blood vessels. In a mouse model of atherosclerosis, inflamed plaques treated with steroid-eluting adhesive gels had reduced macrophage content and developed protective fibrous caps covering the plaque core. Treatment also lowered plasma cytokine levels and biomarkers of inflammation in the plaque. The drug-eluting devices developed here provide a general strategy for implanting therapeutics in the vasculature using adhesive forces and could potentially be used to stabilize rupture-prone plaques. PMID:23236189

  13. Practices and impacts post-exposure to blood and body fluid in operating room nurses: A cross-sectional study.

    PubMed

    Kasatpibal, Nongyao; Whitney, JoAnne D; Katechanok, Sadubporn; Ngamsakulrat, Sukanya; Malairungsakul, Benjawan; Sirikulsathean, Pinyo; Nuntawinit, Chutatip; Muangnart, Thanisara

    2016-05-01

    Improper or inadequate actions taken after blood and body fluid exposures place individuals at risk for infection with bloodborne pathogens. This has potential, significant impact for health and well-being. To evaluate the practices and the personal impact experienced following blood and body fluid exposures among operating room nurses. A cross-sectional, multi-center study. Government and private hospitals from all parts of Thailand. Operating room nurses from 247 hospitals. A questionnaire eliciting responses on characteristics, post-exposure practices, and impacts was sent to 2500 operating room nurses. Usable questionnaires were returned by 2031 operating room nurses (81.2%). Of these 1270 had experience with blood and body fluid exposures (62.5%). Most operating room nurses did not report blood and body fluid exposures (60.9%). The major reasons of underreporting were low risk source (40.2%) and belief that they were not important to report (16.3%). Improper post-exposure practices were identified, 9.8% did not clean exposure area immediately, 18.0% squeezed out the wound, and 71.1% used antiseptic solution for cleansing a puncture wound. Post-exposure, 58.5% of them sought counseling, 16.3% took antiretroviral prophylaxis, 23.8% had serologic testing for hepatitis B and 43.1% for hepatitis C. The main personal impacts were anxiety (57.7%), stress (24.2%), and insomnia (10.2%). High underreporting, inappropriate post-exposure practices and impacts of exposure were identified from this study. Comprehensive education and effective training of post-exposure management may be keys to resolving these important problems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Gastrointestinal and pancreatic hormones in the human fetus and mother at 18-21 weeks of gestation.

    PubMed

    Adrian, T E; Soltesz, G; MacKenzie, I Z; Bloom, S R; Aynsley-Green, A

    1995-01-01

    Several gastrointestinal hormones appear to play an important developmental role in the newborn, particularly in preterm neonates. Although the cells producing these peptides develop towards the end of the first trimester, fetal secretion of these regulatory peptides has not hitherto been demonstrated. Using samples collected by fetoscopy at 19-21 weeks of gestation we have measured concentrations of several gastrointestinal and pancreatic hormones. Maternal venous and amniotic fluid hormone concentrations were measured simultaneously. Concentrations of the pancreatic hormones, insulin, glucagon and pancreatic polypeptide (PP) were similar in fetal and maternal blood. Gastrin and motilin were present in the fetal circulation but at about 30% (p < 0.05) and 60% (p < 0.01) of the maternal levels, respectively. In contrast, enteroglucagon concentrations were more than twofold higher in the fetal circulation compared with maternal levels (p < 0.05). Concentrations of gastric inhibitory polypeptide (GIP) in fetal blood were higher than levels in maternal blood but not significantly. Concentrations of GIP (p < 0.001) were higher in the amniotic fluid than the fetal circulation. Gastrin and glucagon levels were similar in amniotic fluid and fetal blood. In contrast, PP and motilin were present in amniotic fluid, but at lower concentrations than in fetal blood. Enteroglucagon was not detectable in amniotic fluid. In conclusion, several alimentary hormones are secreted in the fetus at midterm. Since these peptides have trophic, secretory and motor effects on the gut, it is likely that these regulatory peptides are involved in the functional development of the fetal intestine.

  15. Metastatic Adenoid Cystic Carcinoma Mimicking Butterfly Glioblastoma: A Rare Presentation in the Splenium of the Corpus Callosum.

    PubMed

    Garber, Sarah T; Khoury, Laith; Bell, Diana; Schomer, Donald F; Janku, Filip; McCutcheon, Ian E

    2016-11-01

    Intracranial spread of an adenoid cystic carcinoma (ACC) of the parotid gland is rare, and metastatic ACC to the splenium of the corpus callosum mimicking butterfly glioblastoma (GBM) has not been reported previously. We report a rare case of metastasis to the splenium of the corpus callosum from ACC of the parotid gland. The tumor occupied the splenium and mimicked the presentation of a butterfly glioma. The patient had undergone parotidectomy 5 years before presentation with this intracranial lesion. On magnetic resonance imaging, the lesion was separate from the pineal gland and displaced the internal cerebral veins downward. Ventricular obstruction and increased cellularity were also suggested, and multiple fluid-filled cystic spaces were observed. The tumor was partially resected, because the extreme lateral boundary could not be visualized. Histological analysis with anti-c-kit antibody showed strong expression of the epithelial component; immunohistochemistry with anti-p63 antibody revealed nests of positive tumor cells, highlighting the myoepithelial component. The tumor also stained positive for anti-Myb antibody. The treatment for this lesion is surgical debulking followed by radiation therapy; however, the overall prognosis remains grim because of limited chemotherapy options and a propensity for recurrence in both local and distant fashions. When a tumor with adenoid histological features and a "butterfly" phenotype grows in the corpus callosum in a patient with known parotid ACC, both metastasis and adenoid variant GBM should be considered. Careful clinical and radiological correlation is required to diagnose and treat this rare lesion. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Viscous Fingering in Multiport Hele Shaw Cell for Controlled Shaping of Fluids.

    PubMed

    Islam, Tanveer Ul; Gandhi, Prasanna S

    2017-11-30

    The pursuit of mimicking complex multiscale systems has been a tireless effort with many successes but a daunting task ahead. A new perspective to engineer complex cross-linked meshes and branched/tree-like structures at different scales is presented here. Control over Saffman-Taylor instability which otherwise randomly rearranges viscous fluid in a 'lifted Hele-Shaw cell' is proposed for the same. The proposed control employs multiple-ports or source-holes in this cell, to spontaneously shape a stretched fluid film into a network of well defined webs/meshes and ordered multiscale tree-like patterns. Use of multiple ports enables exercising strong control to fabricate such structures, in a robust and repeated fashion, which otherwise are completely non-characteristic to viscous fingering process. The proposed technique is capable of fabricating spontaneously families of wide variety of structures over micro and very large scale in a period of few seconds. Thus the proposed method forms a solid foundation to new pathways for engineering multiscale structures for several scientific applications including efficient gas exchange, heat transport, tissue engineering, organ-on-chip, and so on. Proposal of multi-port Hele-Shaw cell also opens new avenues for investigation of complex multiple finger interactions resulting in interesting fluid patterns.

  17. The extracellular calcium-sensing receptor regulates human fetal lung development via CFTR

    PubMed Central

    Brennan, Sarah C.; Wilkinson, William J.; Tseng, Hsiu-Er; Finney, Brenda; Monk, Bethan; Dibble, Holly; Quilliam, Samantha; Warburton, David; Galietta, Luis J.; Kemp, Paul J.; Riccardi, Daniela

    2016-01-01

    Optimal fetal lung growth requires anion-driven fluid secretion into the lumen of the developing organ. The fetus is hypercalcemic compared to the mother and here we show that in the developing human lung this hypercalcaemia acts on the extracellular calcium-sensing receptor, CaSR, to promote fluid-driven lung expansion through activation of the cystic fibrosis transmembrane conductance regulator, CFTR. Several chloride channels including TMEM16, bestrophin, CFTR, CLCN2 and CLCA1, are also expressed in the developing human fetal lung at gestational stages when CaSR expression is maximal. Measurements of Cl−-driven fluid secretion in organ explant cultures show that pharmacological CaSR activation by calcimimetics stimulates lung fluid secretion through CFTR, an effect which in humans, but not mice, was also mimicked by fetal hypercalcemic conditions, demonstrating that the physiological relevance of such a mechanism appears to be species-specific. Calcimimetics promote CFTR opening by activating adenylate cyclase and we show that Ca2+-stimulated type I adenylate cyclase is expressed in the developing human lung. Together, these observations suggest that physiological fetal hypercalcemia, acting on the CaSR, promotes human fetal lung development via cAMP-dependent opening of CFTR. Disturbances in this process would be expected to permanently impact lung structure and might predispose to certain postnatal respiratory diseases. PMID:26911344

  18. Desiccation of a pool of blood: from fluid mechanics to forensic investigations

    NASA Astrophysics Data System (ADS)

    Nicloux, Celine; Brutin, David

    2012-11-01

    The evaporation of biological fluids (with droplet configuration) has been studied since a few years due to several applications in medical fields such as medical tests, drug screening, biostabilization... The evaporation of a drop of whole blood leads to the formation of final typical pattern of cracks. Flow motion, adhesion, gelation and fracturation all occur during the evaporation of this complex matter. During the drying, a sol-gel transition develops. The evaporation of a pool of blood is studied in order to link the pattern formation and the evaporation dynamics. We intend to transfer the knowledge acquired for drops on pool to improve the forensic investigations. In this study, we focus on both pool of blood and pure water to determine the transition region from drop to pool and then to characterize the evaporation rate in the pool configuration. The spreading of blood which can be seen as a complex fluid is strongly influenced the substrate nature. The initial contact angle of blood on different substrate nature will influence the maximum thickness of the layer and then will influence the evaporation mass flux. The authors gratefully acknowledge the help and the fruitful discussions raised with A. Boccoz.

  19. Aquaporin-4 facilitator TGN-073 promotes interstitial fluid circulation within the blood-brain barrier: [17O]H2O JJVCPE MRI study.

    PubMed

    Huber, Vincent J; Igarashi, Hironaka; Ueki, Satoshi; Kwee, Ingrid L; Nakada, Tsutomu

    2018-06-13

    The blood-brain barrier (BBB), which imposes significant water permeability restriction, effectively isolates the brain from the systemic circulation. Seemingly paradoxical, the abundance of aquaporin-4 (AQP-4) on the inside of the BBB strongly indicates the presence of unique water dynamics essential for brain function. On the basis of the highly specific localization of AQP-4, namely, astrocyte end feet at the glia limitans externa and pericapillary Virchow-Robin space, we hypothesized that the AQP-4 system serves as an interstitial fluid circulator, moving interstitial fluid from the glia limitans externa to pericapillary Virchow-Robin space to ensure proper glymphatic flow draining into the cerebrospinal fluid. The hypothesis was tested directly using the AQP-4 facilitator TGN-073 developed in our laboratory, and [O]H2O JJ vicinal coupling proton exchange MRI, a method capable of tracing water molecules delivered into the blood circulation. The results unambiguously showed that facilitation of AQP-4 by TGN-073 increased turnover of interstitial fluid through the system, resulting in a significant reduction in [O]H2O contents of cortex with normal flux into the cerebrospinal fluid. The study further suggested that in addition to providing the necessary water for proper glymphatic flow, the AQP-4 system produces a water gradient within the interstitial space promoting circulation of interstitial fluid within the BBB.

  20. Identification of body fluid-specific DNA methylation markers for use in forensic science.

    PubMed

    Park, Jong-Lyul; Kwon, Oh-Hyung; Kim, Jong Hwan; Yoo, Hyang-Sook; Lee, Han-Chul; Woo, Kwang-Man; Kim, Seon-Young; Lee, Seung-Hwan; Kim, Yong Sung

    2014-11-01

    DNA methylation, which occurs at the 5'-position of the cytosine in CpG dinucleotides, has great potential for forensic identification of body fluids, because tissue-specific patterns of DNA methylation have been demonstrated, and DNA is less prone to degradation than proteins or RNA. Previous studies have reported several body fluid-specific DNA methylation markers, but DNA methylation differences are sometimes low in saliva and vaginal secretions. Moreover, specific DNA methylation markers in four types of body fluids (blood, saliva, semen, and vaginal secretions) have not been investigated with genome-wide profiling. Here, we investigated novel DNA methylation markers for identification of body fluids for use in forensic science using the Illumina HumanMethylation 450K bead array, which contains over 450,000 CpG sites. Using methylome data from 16 samples of blood, saliva, semen, and vaginal secretions, we first selected 2986 hypermethylated or hypomethylated regions that were specific for each type of body fluid. We then selected eight CpG sites as novel, forensically relevant DNA methylation markers: cg06379435 and cg08792630 for blood, cg26107890 and cg20691722 for saliva, cg23521140 and cg17610929 for semen, and cg01774894 and cg14991487 for vaginal secretions. These eight selected markers were evaluated in 80 body fluid samples using pyrosequencing, and all showed high sensitivity and specificity for identification of the target body fluid. We suggest that these eight DNA methylation markers may be good candidates for developing an effective molecular assay for identification of body fluids in forensic science. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  1. CFD simulation of flow through heart: a perspective review.

    PubMed

    Khalafvand, S S; Ng, E Y K; Zhong, L

    2011-01-01

    The heart is an organ which pumps blood around the body by contraction of muscular wall. There is a coupled system in the heart containing the motion of wall and the motion of blood fluid; both motions must be computed simultaneously, which make biological computational fluid dynamics (CFD) difficult. The wall of the heart is not rigid and hence proper boundary conditions are essential for CFD modelling. Fluid-wall interaction is very important for real CFD modelling. There are many assumptions for CFD simulation of the heart that make it far from a real model. A realistic fluid-structure interaction modelling the structure by the finite element method and the fluid flow by CFD use more realistic coupling algorithms. This type of method is very powerful to solve the complex properties of the cardiac structure and the sensitive interaction of fluid and structure. The final goal of heart modelling is to simulate the total heart function by integrating cardiac anatomy, electrical activation, mechanics, metabolism and fluid mechanics together, as in the computational framework.

  2. Giant intracranial aneurysm embolization with a yield stress fluid material: insights from CFD analysis.

    PubMed

    Wang, Weixiong; Graziano, Francesca; Russo, Vittorio; Ulm, Arthur J; De Kee, Daniel; Khismatullin, Damir B

    2013-01-01

    The endovascular treatment of intracranial aneurysms remains a challenge, especially when the aneurysm is large in size and has irregular, non-spherical geometry. In this paper, we use computational fluid dynamics to simulate blood flow in a vertebro-basilar junction giant aneurysm for the following three cases: (1) an empty aneurysm, (2) an aneurysm filled with platinum coils, and (3) an aneurysm filled with a yield stress fluid material. In the computational model, blood and the coil-filled region are treated as a non-Newtonian fluid and an isotropic porous medium, respectively. The results show that yield stress fluids can be used for aneurysm embolization provided the yield stress value is 20 Pa or higher. Specifically, flow recirculation in the aneurysm and the size of the inflow jet impingement zone on the aneurysm wall are substantially reduced by yield stress fluid treatment. Overall, this study opens up the possibility of using yield stress fluids for effective embolization of large-volume intracranial aneurysms.

  3. Canine blood volume and cardiovascular function during hyperthermia.

    PubMed

    Miki, K; Morimoto, T; Nose, H; Itoh, T; Yamada, S

    1983-08-01

    The effect of acute hyperthermia on hemodynamic functions and blood volume regulation was examined on eight splenectomized dogs. Elevation of core body temperature by 2 degrees C over 90 min caused significant increase in cardiac output (11.2 +/- 12.5 ml X min-1 X kg-1 or about 10%) and significant decrease in total peripheral resistance (TPR; -1.3 +/- 1.0 mmHg X s X ml-1 or about 20%), whereas blood volume (BV), plasma oncotic pressure, and intravascular protein mass remained unchanged. Thus the raised core temperature caused peripheral vasodilation with decreased TPR and compensatory increase in cardiac output. Because BV remained unchanged during warming, mobilization of extravascular fluid did not occur; only the redistribution of blood to the vasodilated cutaneous circulation took place. To assess the effects of heat stress on transvascular fluid equilibrium, Ringer solution (10.7 ml X kg-1 X 10 min-1) was infused under normothermic and hyperthermic conditions. The volume of fluid retained within the intravascular space under equilibrium state was 33.5% in hyperthermia and 9.4% in normothermia. In hyperthermia, the transvascular fluid shift and urinary output were decreased both during and after infusion. The role of preferential fluid retention within the intravascular space observed during hyperthermia was discussed in relation to the mechanism to maintain cardiovascular function and BV under heat stress.

  4. Water Flow through Xylem: An Investigation of a Fluid Dynamics Principle Applied to Plants

    ERIC Educational Resources Information Center

    Rice, Stanley A.; McArthur, John

    2004-01-01

    A study was conducted to prove that a large blood or xylem vessel could conduct 256 times more fluid than a vessel or a pipe that is four times smaller. The result of this study proved that if arteriosclerosis causes an artery to loose half its effective diameter, the blood flow would be reduced by fifteen-sixteenths.

  5. COLDEX-86: Fluid and Electrolyte Changes during Prolonged Cold Water Immersion

    DTIC Science & Technology

    1990-12-01

    4 Urine and blood collections .................. ..................... 5 Sample processing and biochemical analyses...and decaffeinated tea and coffee. Ingestion of fluids was encouraged. After completing the immersion, 16 oz of warm apple or cranberry juice was...day. Sample processing and biochemical analyses. Blood samples (25 ml) were drawn from an antecubital vein with minimum stasis. Each sample was divided

  6. Servo-control of water and sodium homeostasis during renal clearance measurements in conscious rats.

    PubMed

    Thomsen, Klaus; Shirley, David G

    2007-01-01

    Servo-controlled fluid and sodium replacement during clearance studies is used in order to prevent loss of body fluid and sodium following diuretic/natriuretic procedures. However, even under control conditions, the use of this technique is sometimes associated with increases in proximal tubular fluid output (assessed by lithium clearance) and excretion rates. The present study examined the reason for these increases. The first series of experiments showed that one cause is volume overloading. This can occur if the servo system is activated from the start, i.e., during the establishment of a suitably high urine flow rate by constant infusion of hypotonic glucose solution. The second series of experiments showed that replacement of blood samples with donor blood can also lead to increases in fractional lithium excretion and accompanying increases in water and sodium excretion, a problem not seen when blood samples are replaced with the animal's own red blood cells resuspended in isotonic saline. When these pitfalls are avoided, servo-controlled sodium and fluid replacement is a reliable technique that makes it possible to study the effects of natriuretic and/or diuretic stimuli without interference from unwanted changes in extracellular volume. 2007 S. Karger AG, Basel

  7. A Novel Chronic Opioid Monitoring Tool to Assess Prescription Drug Steady State Levels in Oral Fluid.

    PubMed

    Shaparin, Naum; Mehta, Neel; Kunkel, Frank; Stripp, Richard; Borg, Damon; Kolb, Elizabeth

    2017-11-01

    Interpretation limitations of urine drug testing and the invasiveness of blood toxicology have motivated the desire for the development of simpler methods to assess biologically active drug levels on an individualized patient basis. Oral fluid is a matrix well-suited for the challenge because collections are based on simple noninvasive procedures and drug concentrations better correlate to blood drug levels as oral fluid is a filtrate of the blood. Well-established pharmacokinetic models were utilized to generate oral fluid steady state concentration ranges to assess the interpretive value of the alternative matrix to monitor steady state plasma oxycodone levels. Paired oral fluid and plasma samples were collected from patients chronically prescribed oxycodone and quantitatively analyzed by liquid chromatography tandem mass spectrometry. Steady state plasma concentration ranges were calculated for each donor and converted to an equivalent range in oral fluid. Measured plasma and oral fluid oxycodone concentrations were compared with respective matrix-matched steady state ranges, using each plasma steady state classification as the control. A high degree of correlation was observed between matrices when classifying donors according to expected steady state oxycodone concentration. Agreement between plasma and oral fluid steady state classifications was observed in 75.6% of paired samples. This study supports novel application of basic pharmacokinetic knowledge to the pain management industry, simplifying and improving individualized drug monitoring and risk assessment through the use of oral fluid drug testing. Many benefits of established therapeutic drug monitoring in plasma can be realized in oral fluid for patients chronically prescribed oxycodone at steady state. © 2017 American Academy of Pain Medicine. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  8. 21 CFR 1271.3 - How does FDA define important terms in this part?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...

  9. 21 CFR 1271.3 - How does FDA define important terms in this part?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...

  10. 21 CFR 1271.3 - How does FDA define important terms in this part?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...

  11. 21 CFR 1271.3 - How does FDA define important terms in this part?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... resulting from the transfusion of blood or blood components and/or infusion of fluids. (q) Quarantine means... blood, manipulated autologous chondrocytes, epithelial cells on a synthetic matrix, and semen or other... transplantation; (2) Whole blood or blood components or blood derivative products subject to listing under parts...

  12. Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

    NASA Technical Reports Server (NTRS)

    Verbanck, S.; Larsson, H.; Linnarsson, D.; Prisk, G. K.; West, J. B.; Paiva, M.

    1997-01-01

    In microgravity (microG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to microG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls (P < 0.001). There was a concomittant reduction in stroke volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P < 0.05) late in flight. These findings suggest that, despite increased pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to microG.

  13. Fluconazole levels in serum and cerebrospinal fluid according to daily dosage in patients with cryptococcosis and other fungal infections.

    PubMed

    Schiave, Letícia Aparecida; Nascimento, Erika; Vilar, Fernando Crivelenti; de Haes, Tissiana Marques; Takayanagui, Osvaldo Massaiti; Gaitani, Cristiane Masetto de; Martinez, Roberto

    Fluconazole is extensively used for the treatment of candidiasis and cryptococcosis. Among other factors, successful treatment is related to appropriate fluconazole levels in blood and cerebrospinal fluid. In the present study, fluconazole levels were determined in 15 patients, 14 of whom had AIDS and 13 had neurocryptococcosis. The only selection criterion was treatment with fluconazole, which was performed with a generic or similar form of the drug. Fluconazole level was determined by high performance liquid chromatography and the susceptibility profile of Cryptococcus spp. isolated from the patients was assessed by broth microdilution. Blood and cerebrospinal fluid fluconazole levels were found to be related to the fluconazole daily dose, and exceeded the minimum inhibitory concentration of this antifungal for the Cryptococcus spp. isolates. A good correlation was observed between serum and cerebrospinal fluid drug concentration. In conclusion, treatment with non-original fluconazole under usual medical practice conditions results in appropriate blood and cerebrospinal fluid levels of the drug for inhibiting Cryptococcus spp. susceptible to this antifungal drug. The relatively common failures of neurocryptococcosis treatment appear not to be due to insufficient fluconazole levels in the cerebrospinal fluid, especially with the use of daily doses of 400-800mg. Copyright © 2017 Sociedade Brasileira de Infectologia. Published by Elsevier Editora Ltda. All rights reserved.

  14. Development of mRNA-based body fluid identification using reverse transcription loop-mediated isothermal amplification.

    PubMed

    Satoh, Tetsuya; Kouroki, Seiya; Ogawa, Keita; Tanaka, Yorika; Matsumura, Kazutoshi; Iwase, Susumu

    2018-04-25

    Identifying body fluids from forensic samples can provide valuable evidence for criminal investigations. Messenger RNA (mRNA)-based body fluid identification was recently developed, and highly sensitive parallel identification using reverse transcription polymerase chain reaction (RT-PCR) has been described. In this study, we developed reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a simple, rapid assay for identifying three common forensic body fluids, namely blood, semen, and saliva, and evaluated its specificity and sensitivity. Hemoglobin beta (HBB), transglutaminase 4 (TGM4), and statherin (STATH) were selected as marker genes for blood, semen, and saliva, respectively. RT-LAMP could be performed in a single step including both reverse transcription and DNA amplification under an isothermal condition within 60 min, and detection could be conveniently performed via visual fluorescence. Marker-specific amplification was performed in each assay, and no cross-reaction was observed among five representative forensically relevant body fluids. The detection limits of the assays were 0.3 nL, 30 nL, and 0.3 μL for blood, semen, and saliva, respectively, and their sensitivities were comparable with those of RT-PCR. Furthermore, RT-LAMP assays were applicable to forensic casework samples. It is considered that RT-LAMP is useful for body fluid identification.

  15. Numerical Investigation of Oxygenated and Deoxygenated Blood Flow through a Tapered Stenosed Arteries in Magnetic Field.

    PubMed

    Abdollahzadeh Jamalabadi, M Y; Akbari Bidokhti, Amin Ali; Khak Rah, Hamid; Vaezi, Siavash; Hooshmand, Payam

    2016-01-01

    Current paper is focused on transient modeling of blood flow through a tapered stenosed arteries surrounded a by solenoid under the presence of heat transfer. The oxygenated and deoxygenated blood are considered here by the Newtonian and Non-Newtonian fluid (power law and Carreau-Yasuda) models. The governing equations of bio magnetic fluid flow for an incompressible, laminar, homogeneous, non-Newtonian are solved by finite volume method with SIMPLE algorithm for structured grid. Both magnetization and electric current source terms are well thought-out in momentum and energy equations. The effects of fluid viscosity model, Hartmann number, and magnetic number on wall shear stress, shearing stress at the stenosis throat and maximum temperature of the system are investigated and are optimized. The current study results are in agreement with some of the existing findings in the literature and are useful in thermal and mechanical design of spatially varying magnets to control the drug delivery and biomagnetic fluid flows through tapered arteries.

  16. Assessment and Management of Volume Overload and Congestion in Chronic Heart Failure: Can Measuring Blood Volume Provide New Insights?

    PubMed

    Miller, Wayne L

    2017-01-01

    Volume overload and fluid congestion remain primary clinical challenges in the assessment and management of patients with chronic heart failure (HF). The pathophysiology of volume regulation is complex, and the simple concept of passive intravascular fluid accumulation is not adequate. The dynamics of interstitial and intravascular fluid compartment interactions and fluid redistribution from venous splanchnic beds to the central pulmonary circulation need to be taken into account in strategies of volume management. Clinical bedside evaluations and right heart hemodynamic assessments can alert of changes in volume status, but only the quantitative measurement of total blood volume can help identify the heterogeneity in plasma volume and red blood cell mass that are features of volume overload in chronic HF. The quantitative assessment of intravascular volume is an effective tool to help guide individualized, appropriate therapy. Not all volume overload is the same, and the measurement of intravascular volume identifies heterogeneity to guide tailored therapy.

  17. Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt

    NASA Technical Reports Server (NTRS)

    Frey, Mary A. B.; Mader, Thomas H.; Bagian, James P.; Charles, John B.; Meehan, Richard T.

    1993-01-01

    Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.

  18. A case of chronic active Epstein-Barr virus infection mimicking adult-onset Still's disease.

    PubMed

    Yoshioka, Katsunobu; Fukushima, Hiroko; Ishii, Naomi; Kita, Akiko; Hanioka, Yusuke; Minami, Mieko; Inoue, Takeshi; Yamagami, Keiko

    2013-01-01

    An 83-year-old man was diagnosed with adult-onset Still's disease (AOSD) based on clinical and laboratory findings. However, glucocorticoid had little effect. Epstein-Barr virus (EBV)-DNA was detected in peripheral blood, and autopsy findings confirmed a diagnosis of chronic active EBV infection (CAEBV). CAEBV mimics AOSD, and the presence of articular involvement and leukocytosis does not exclude the possibility of CAEBV. CAEBV should be included in the differential diagnosis of AOSD, and measurement of EBV-DNA is essential.

  19. Comparison between self-report of cannabis use and toxicological detection of THC/THCCOOH in blood and THC in oral fluid in drivers in a roadside survey.

    PubMed

    Van der Linden, Trudy; Silverans, Peter; Verstraete, Alain G

    2014-01-01

    The objective of this study was to compare the number of drivers who self-reported cannabis use by questionnaires to the results of toxicological analysis. During roadside surveys, 2957 respondents driving a personal car or van completed a questionnaire to report their use of drugs and medicines during the previous two weeks and to indicate the time of their last intake. Cannabis was analyzed in oral fluid by ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), in blood by gas chromatography-mass spectrometry (GC-MS). Frequencies in the time categories were calculated and compared with toxicological results. Diagnostic values were calculated for the time categories in which positive findings were to be expected (<4 h and <2 4h, respectively for tetrahydrocannabinol (THC) and delta9-tetrahydrocannabinol (THCCOOH) in blood, <12 h for THC in oral fluid). Most self-reported cannabis use was more than 12 h before driving. The sensitivity of the questionnaire was low, while the specificity and accuracy were high. Kappa statistics revealed a fair agreement between self-report and positive findings for THC in oral fluid and blood and moderate agreement with THCCOOH in blood. Self-report largely underestimates driving under the influence of cannabis, particularly recent cannabis use; therefore analysis of biological samples is necessary. Copyright © 2013 John Wiley & Sons, Ltd.

  20. A refractometry-based glucose analysis of body fluids.

    PubMed

    Zirk, Kai; Poetzschke, Harald

    2007-05-01

    In principle, refractometry appears to be a suitable method for the measurement of glucose concentrations in body fluids (such as blood and the intercellular fluid), even though the refractive index of the measured samples, as an additive property, is not specific. But, if certain conditions are fulfilled, the glucose content can be calculated using the refractive index in combination with values from a further measurement. This study describes the determination of the glucose content using refractometry in human blood serum derivates, which were selected - due to their ready availability - to be used as a model for interstitial fluid. Refractometry of body fluids requires the elimination of disturbing components from the measurement sample. First of all, a homogenous fluid (i.e. consisting of one phase) is required, so that all cells and components in suspension need to be separated out. Furthermore, certain dissolved macromolecular components which are known to disturb the measurement process must also be removed. In human serum samples which had been ultrafiltrated with a range of ultrafilters of different pore sizes, a comparative evaluation showed that only ultrafiltration through a filter with a separation limit of between 3 and 30kDa resulted in maximal reduction of the refractive index (compared to native serum), whereas ultrafilters with greater separation limits did not. The total content of osmotically active solutes (the tonicity) also exerts a clear influence. However, exemplary measurements in blood plasma fluid from one volunteer showed that the electrical conductivity is (without an additive component) directly proportional to the osmolality: physiological changes in the state of body hydration (hyperhydration and dehydration) do not lead to any considerable changes in the relation between ionised and uncharged solute particles, but instead result in a sufficiently clear dilution or concentration of the blood fluid's low molecular components. This finding allows the use of the--technically easy to measure--electrical conductivity as a measure for the tonicity of the measurement samples. Using measurements of these two parameters--refractive index and electrical conductivity--in blood serum obtained from a healthy volunteer, a two-dimensional calibration function (calibration matrix) for the assessment of the glucose content of ultrafiltrated human blood serum was constructed, and the measurement of blood glucose levels in non-diabetic (four females and four males) volunteers in comparison to a reference method was evaluated showing (as a proof of concept) a linear association. Assessment of the inaccuracy of these measurements made with the described measuring devices and methods showed a deviation from the reference values of less than 10%. An estimation of the maximum possible error showed relative deviations (maximum measurement uncertainties) of up to 20%.

  1. A new method to measure muscle protein synthesis in humans by endogenously introduced d9-leucine and using blood for precursor enrichment determination

    PubMed Central

    Tran, Lee; Masters, Haley; Roust, Lori R; Katsanos, Christos S

    2015-01-01

    Enrichment from the easily accessible blood amino acid pool is commonly used as precursor enrichment to calculate rates of muscle protein fractional synthesis in relevant human studies in lieu of the less accessible muscle fluid amino acid pool. However, the accuracy of this approach depends largely on the extent to which there is low discrepancy in free amino acid enrichment between blood and muscle. Steady-state gradient (i.e., ratio) of amino acid enrichment between blood and muscle fluid in the basal state and in response to amino acid infusion were determined in five healthy subjects, and in association with two separate tracers: d9-leucine, introduced endogenously by the metabolism of d10-leucine (i.e., l-[2,3,3,4,5,5,5,6,6,6-2H10]leucine) infused in blood, and 13C6-phenylalanine introduced/infused in blood. The blood-to-muscle fluid amino acid enrichment ratio was lower (P < 0.05) for d9-leucine compared to 13C6-phenylalanine both before (1.5 ± 0.1 vs. 2.5 ± 0.1) and during (1.1 ± 0.1 vs. 1.2 ± 0.1) amino acid infusion. Importantly, the decrease in this ratio in association with the amino acid infusion was considerably less for the d9-leucine than the 13C6-phenylalanine (−0.38 ± 0.03 vs. −1.29 ± 0.07; P < 0.05). In conclusion, blood d9-leucine enrichment introduced endogenously by intravenous infusion of d10-leucine provides a closer estimate of the muscle fluid amino acid enrichment, and its associated changes, than blood phenylalanine enrichment to calculate rates of muscle protein synthesis in humans. PMID:26243214

  2. Growth and Remodeling in Blood Vessels Studied In Vivo With Fractal Analysis

    NASA Technical Reports Server (NTRS)

    Parsons-Wingerter, Patricia A.

    2003-01-01

    Every cell in the human body must reside in close proximity to a blood vessel (within approximately 200 mm) because blood vessels provide the oxygen, metabolite, and fluid exchanges required for cellular existence. The growth and remodeling of blood vessels are required to support the normal physiology of embryonic development, reproductive biology, wound healing and adaptive remodeling to exercise, as well as abnormal tissue change in diseases such as cancer, diabetes, and coronary heart disease. Cardiovascular and hemodynamic (blood flow dynamics) alterations experienced by astronauts during long-term spaceflight, including orthostatic intolerance, fluid shifts in the body, and reduced numbers of red (erythrocyte) and white (immune) blood cells, are identified as risk factors of very high priority in the NASA task force report on risk reduction for human spaceflight, the "Critical Path Roadmap."

  3. Development of a model to assess orthostatic responses

    NASA Technical Reports Server (NTRS)

    Rubin, Marilyn

    1993-01-01

    A major change for crewmembers during weightlessness in microgravity is the redistribution of body fluids from the legs into the abdomen, thorax, and head. The fluids continue to be sequestered in these areas throughout the flight. Upon reentry into gravity on landing, these same body fluids are displaced again to their normal locations, however, not without hazardous incidence to the crewmembers. The problem remains that upon landing, crewmembers are subject to orthostasis, that is, the blood flowing into the legs reduces the blood supply to the brain and may result in the crewmember fainting. The purpose of this study was to develop a model of testing orthostatic responses of blood pressure regulating mechanisms of the cardiovascular system, when challenged, to maintain blood pressure to the brain. To accomplish this, subjects' responses were assessed as they proceeded from the supine position of progressive head-up tilt positions of 30 deg, 60 deg, and 90 deg angles. A convenience sample consisted of 21 subjects, females (N=11) and males (N=10), selected from a list of potential subjects available through the NASA subject screening office. The methodology included all non-invasive measurements of blood pressure, heart rate, echocardiograms, cardiac output, cardiac stroke volume, fluid shifts in the thorax, ventricular ejection and velocity times, and skin blood perfusion. The Fischer statistical analysis was done of all data with the significance level at .05. Significant differences were demonstrated in many instances of changes of posture for all variables. Based on the significance of the findings of this study, this model for assessing orthostatic responses does provide an adequate challenge to the blood pressure regulatory systems. While individuals may use different adaptations to incremental changes in gravity, the subjects, in aggregate, demonstrated significant adaptive cardiovascular changes to orthostatic challenges which were presented to them.

  4. Coupling molecular dynamics with lattice Boltzmann method based on the immersed boundary method

    NASA Astrophysics Data System (ADS)

    Tan, Jifu; Sinno, Talid; Diamond, Scott

    2017-11-01

    The study of viscous fluid flow coupled with rigid or deformable solids has many applications in biological and engineering problems, e.g., blood cell transport, drug delivery, and particulate flow. We developed a partitioned approach to solve this coupled Multiphysics problem. The fluid motion was solved by Palabos (Parallel Lattice Boltzmann Solver), while the solid displacement and deformation was simulated by LAMMPS (Large-scale Atomic/Molecular Massively Parallel Simulator). The coupling was achieved through the immersed boundary method (IBM). The code modeled both rigid and deformable solids exposed to flow. The code was validated with the classic problem of rigid ellipsoid particle orbit in shear flow, blood cell stretching test and effective blood viscosity, and demonstrated essentially linear scaling over 16 cores. An example of the fluid-solid coupling was given for flexible filaments (drug carriers) transport in a flowing blood cell suspensions, highlighting the advantages and capabilities of the developed code. NIH 1U01HL131053-01A1.

  5. Low central venous pressure versus acute normovolemic hemodilution versus conventional fluid management for reducing blood loss in radical retropubic prostatectomy: a randomized controlled trial.

    PubMed

    Habib, Ashraf S; Moul, Judd W; Polascik, Thomas J; Robertson, Cary N; Roche, Anthony M; White, William D; Hill, Stephen E; Nosnick, Israel; Gan, Tong J

    2014-05-01

    To compare acute normovolemic hemodilution versus low central venous pressure strategy versus conventional fluid management in reducing intraoperative estimated blood loss, hematocrit drop and need for blood transfusion in patients undergoing radical retropubic prostatectomy under general anesthesia. Patients undergoing radical retropubic prostatectomy under general anesthesia were randomized to conventional fluid management, acute normovolemic hemodilution or low central venous pressure (≤5 mmHg). Treatment effects on estimated blood loss and hematocrit change were tested in multivariable regression models accounting for surgeon, prostate size, and all two-way interactions. Ninety-two patients completed the study. Estimated blood loss (mean ± SD) was significantly lower with low central venous pressure (706 ± 362 ml) compared to acute normovolemic hemodilution (1103 ± 635 ml) and conventional (1051 ± 714 ml) groups (p = 0.0134). There was no difference between the groups in need for blood transfusion, or hematocrit drop from preoperative values. The multivariate model predicting estimated blood loss showed a significant effect of treatment (p = 0.0028) and prostate size (p = 0.0323), accounting for surgeon (p = 0.0013). In the model predicting hematocrit change, accounting for surgeon difference (p = 0.0037), the treatment effect depended on prostate size (p = 0.0007) with the slope of low central venous pressure differing from the other two groups. Hematocrit was predicted to drop more with increased prostate size in acute normovolemic hemodilution and conventional groups but not with low central venous pressure. Limitations include the inability to blind providers to group assignment, possible variability between providers in estimation of blood loss, and the relatively small sample size that was not powered to detect differences between the groups in need for blood transfusion. Maintaining low central venous pressure reduced estimated blood loss compared to conventional fluid management and acute normovolemic hemodilution in patients undergoing radical retropubic prostatectomy but there was no difference in allogeneic blood transfusion between the groups.

  6. The Radioimmunoassay of Fluid and Electrolyte Hormones

    NASA Technical Reports Server (NTRS)

    Keil, Lanny C.

    1985-01-01

    The subject of the paper will be the assay of fluid/electrolyte hormones. ADH (antidiuretic hormone also referred to as vasopressin) reduces fluid loss by increasing water reabsorption by the kidney. The stimuli for its release from the pituitary are loss of blood, dehydration, or increased salt intake. Angiotensin II is the next hormone of interest. It is "generated" from a blood protein by the release of renin from the kidney. One of its functions is to stimulate the secretion of aldosterone from the adrenal gland. Release of renin is also stimulated by volume and sodium loss.

  7. Improvement of autonomic nervous regulation by blood purification therapy using acetate-free dialysis fluid - clinical evaluation by laser Doppler flowmetry.

    PubMed

    Sato, Takashi; Taoka, Masahiro; Miyahara, Takaaki

    2011-01-01

    In Japan, acetate-free biofiltration (AFBF) became commercially available in the year 2000, and these products have been reported to be clinically effective for controlling the decrease of blood pressure during dialysis or various types of dialysis intolerance. And more, acetate-free dialysis fluid was made clinically available in 2007, acetate-free hemodialysis (AFHD) is expected to inhibit the malnutrition-inflammation-atherosclerosis syndrome, improve anemia and the nutritional status of patients, stabilize hemodynamics, and reduce inflammation and oxidative stress. In a broad sense, AFBF can be classified as hemodiafiltration (HDF), and its clinical effects seem to be associated with multiple factors, including use of acetate-free dialysis fluid, massive removal of low molecular weight proteins by convection, and the sodium concentration of the replacement fluid. Therefore, the clinical significance of acetate-free dialysis fluid could be demonstrated more clearly by comparing AFHD with conventional hemodialysis (conv. HD) using dialysis fluid containing about 10 mEq/l acetate. Since 2005, we have been investigating the efficacy of various modalities of blood purification therapy by continuously monitoring changes of tissue blood flow in the lower limbs and earlobes (head) using non-invasive continuous monitoring method (NICOMM). In this report, we assess the clinical effectiveness of AFHD on the basis of clinical findings and head stability index (head SI) obtained by NICOMM, particularly with respect to the influence on autonomic regulation. After switching to AFHD from conv. HD, anemia, stored iron utilization, and the frequency of treatments for dialysis hypotension and of muscle cramps were significantly improved. Further, the head SI was also significantly smaller with AFHD than conv. HD. This finding suggests that AFHD improved the maintenance of homeostasis by the autonomic nervous regulation system. In addition, we could not find clinical features of excessive alkalosis during an observation period of about 1 year, even if online HDF using acetate-free dialysis fluid as the substitution fluid. Our conclusion is that the advent of acetate-free dialysis fluid has led to investigations into new clinical effectiveness of AFHD or online HDF/HF using ultrapurified acetate-free dialysis fluid as the substitution fluid. Copyright © 2011 S. Karger AG, Basel.

  8. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  9. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  10. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  11. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  12. The interrelationship of research in the laboratory and the field to assess hydration status and determine mechanisms involved in water regulation during physical activity.

    PubMed

    Stachenfeld, Nina S

    2014-05-01

    Changes in skin blood and sweating are the primary mechanisms for heat loss in humans. A hot, humid environment concomitant with dehydration limits the ability to increase skin blood flow for the purpose of transferring heat from the body core to skin surface and evaporate sweat to maintain core temperature within safe limits during exercise. Adequate hydration improves thermoregulation by maintaining blood volume to support skin blood flow and sweating. Humans rely on fluid intake to maintain total body water and blood volume, and have developed complex mechanisms to sense changes in the amount and composition of fluid in the body. This paper addresses the interrelationship of research in the laboratory and the field to assess hydration status involved in body water and temperature regulation during exercise. In the controlled setting of a research laboratory, investigators are able to investigate the contributions of volume and tonicity of fluid in the plasma to body water and temperature regulation during exercise and recovery. For example, laboratory studies have shown that tonicity in a rehydration beverage maintains the thirst mechanism (and stimulates drinking), and contributes to the ongoing stimulation of renal fluid retention hormones, ultimately leading to a more complete rehydration. Research in the field cannot control the environment precisely, but these studies provide a natural, 'real-life' setting to study fluid and temperature regulation during exercise. The conditions encountered in the field are closest to the environment during competition, and data collected in the field can have an immediate impact on performance and safety during exercise. There is an important synergy between these two methods of collecting data that support performance and protect athletes from harm during training and improve performance during competition.

  13. Simultaneous determination of nikethamide and lidocaine in human blood and cerebrospinal fluid by high performance liquid chromatography.

    PubMed

    Chen, Lili; Liao, Linchuan; Zuo, Zhong; Yan, Youyi; Yang, Lin; Fu, Qiang; Chen, Yu; Hou, Junhong

    2007-04-11

    Nikethamide and lidocaine are often requested to be quantified simultaneously in forensic toxicological analysis. A simple reversed-phase high performance liquid chromatography (RP-HPLC) method has been developed for their simultaneous determination in human blood and cerebrospinal fluid. The method involves simple protein precipitation sample treatment followed by quantification of analytes using HPLC at 263 nm. Analytes were separated on a 5 microm Zorbax Dikema C18 column (150 mm x 4.60 mm, i.d.) with a mobile phase of 22:78 (v/v) mixture of methanol and a diethylamine-acetic acid buffer, pH 4.0. The mean recoveries were between 69.8 and 94.4% for nikethamide and between 78.9 and 97.2% for lidocaine. Limits of detection (LODs) for nikethamide and lidocaine were 0.008 and 0.16 microg/ml in plasma and 0.007 and 0.14 microg/ml in cerebrospinal fluid, respectively. The mean intra-assay and inter-assay coefficients of variation (CVs) for both analytes were less than 9.2 and 10.8%, respectively. The developed method was applied to blood sample analyses in eight forensic cases, where blood concentrations of lidocaine ranged from 0.68 to 34.4 microg/ml and nikethamide ranged from 1.25 to 106.8 microg/ml. In six cases cerebrospinal fluid analysis was requested. The values ranged from 20.3 to 185.6 microg/ml of lidocaine and 8.0 to 72.4 microg/ml of nikethamide. The method is simple and sensitive enough to be used in toxicological analysis for simultaneous determination of nikethamide and lidocaine in blood and cerebrospinal fluid.

  14. Direct visualization of antigen-specific T cells: HTLV-1 Tax11-19- specific CD8(+) T cells are activated in peripheral blood and accumulate in cerebrospinal fluid from HAM/TSP patients.

    PubMed

    Greten, T F; Slansky, J E; Kubota, R; Soldan, S S; Jaffee, E M; Leist, T P; Pardoll, D M; Jacobson, S; Schneck, J P

    1998-06-23

    Human T lymphotropic virus type 1 (HTLV-1) -associated myelopathy/tropic spastic paraparesis is a demyelinating inflammatory neurologic disease associated with HTLV-1 infection. HTLV-1 Tax11-19-specific cytotoxic T cells have been isolated from HLA-A2-positive patients. We have used a peptide-loaded soluble HLA-A2-Ig complex to directly visualize HTLV-1 Tax11-19-specific T cells from peripheral blood and cerebrospinal fluid without in vitro stimulation. Five of six HTLV-1-associated myelopathy/tropic spastic paraparesis patients carried a significant number (up to 13.87%) of CD8(+) lymphocytes specific for the HTLV-1 Tax11-19 peptide in their peripheral blood, which were not found in healthy controls. Simultaneous comparison of peripheral blood and cerebrospinal fluid from one patient revealed 2.5-fold more Tax11-19-specific T cells in the cerebrospinal fluid (23.7% vs. 9.4% in peripheral blood lymphocyte). Tax11-19-specific T cells were seen consistently over a 9-yr time course in one patient as far as 19 yrs after the onset of clinical symptoms. Further analysis of HTLV-1 Tax11-19-specific CD8(+) T lymphocytes in HAM/TSP patients showed different expression patterns of activation markers, intracellular TNF-alpha and gamma-interferon depending on the severity of the disease. Thus, visualization of antigen-specific T cells demonstrates that HTLV-1 Tax11-19-specific CD8(+) T cells are activated, persist during the chronic phase of the disease, and accumulate in cerebrospinal fluid, showing their pivotal role in the pathogenesis of this neurologic disease.

  15. Generation mechanism of RANKL(+) effector memory B cells: relevance to the pathogenesis of rheumatoid arthritis.

    PubMed

    Ota, Yuri; Niiro, Hiroaki; Ota, Shun-Ichiro; Ueki, Naoko; Tsuzuki, Hirofumi; Nakayama, Tsuyoshi; Mishima, Koji; Higashioka, Kazuhiko; Jabbarzadeh-Tabrizi, Siamak; Mitoma, Hiroki; Akahoshi, Mitsuteru; Arinobu, Yojiro; Kukita, Akiko; Yamada, Hisakata; Tsukamoto, Hiroshi; Akashi, Koichi

    2016-03-16

    The efficacy of B cell-depleting therapies for rheumatoid arthritis underscores antibody-independent functions of effector B cells such as cognate T-B interactions and production of pro-inflammatory cytokines. Receptor activator of nuclear factor κB ligand (RANKL) is a key cytokine involved in bone destruction and is highly expressed in synovial fluid B cells in patients with rheumatoid arthritis. In this study we sought to clarify the generation mechanism of RANKL(+) effector B cells and their impacts on osteoclast differentiation. Peripheral blood and synovial fluid B cells from healthy controls and patients with rheumatoid arthritis were isolated using cell sorter. mRNA expression of RANKL, osteoprotegerin, tumor necrosis factor (TNF)-α, and Blimp-1 was analyzed by quantitative real-time polymerase chain reaction. Levels of RANKL, CD80, CD86, and CXCR3 were analyzed using flow cytometry. Functional analysis of osteoclastogenesis was carried out in the co-culture system using macrophage RAW264 reporter cells. RANKL expression was accentuated in CD80(+)CD86(+) B cells, a highly activated B-cell subset more abundantly observed in patients with rheumatoid arthritis. Upon activation via B-cell receptor and CD40, switched-memory B cells predominantly expressed RANKL, which was further augmented by interferon-γ (IFN-γ) but suppressed by interleukin-21. Strikingly, IFN-γ also enhanced TNF-α expression, while it strongly suppressed osteoprotegerin expression in B cells. IFN-γ increased the generation of CXCR3(+)RANKL(+) effector B cells, mimicking the synovial B cell phenotype in patients with rheumatoid arthritis. Finally, RANKL(+) effector B cells in concert with TNF-α facilitated osteoclast differentiation in vitro. Our current findings have shed light on the generation mechanism of pathogenic RANKL(+) effector B cells that would be an ideal therapeutic target for rheumatoid arthritis in the future.

  16. Water reservoir maintained by cell growth fuels the spreading of a bacterial swarm

    PubMed Central

    Wu, Yilin; Berg, Howard C.

    2012-01-01

    Flagellated bacteria can swim across moist surfaces within a thin layer of fluid, a means for surface colonization known as swarming. This fluid spreads with the swarm, but how it does so is unclear. We used micron-sized air bubbles to study the motion of this fluid within swarms of Escherichia coli. The bubbles moved diffusively, with drift. Bubbles starting at the swarm edge drifted inward for the first 5 s and then moved outward. Bubbles starting 30 μm from the swarm edge moved inward for the first 20 s, wandered around in place for the next 40 s, and then moved outward. Bubbles starting at 200 or 300 μm from the edge moved outward or wandered around in place, respectively. So the general trend was inward near the outer edge of the swarm and outward farther inside, with flows converging on a region about 100 μm from the swarm edge. We measured cellular metabolic activities with cells expressing a short-lived GFP and cell densities with cells labeled with a membrane fluorescent dye. The fluorescence plots were similar, with peaks about 80 μm from the swarm edge and slopes that mimicked the particle drift rates. These plots suggest that net fluid flow is driven by cell growth. Fluid depth is largest in the multilayered region between approximately 30 and 200 μm from the swarm edge, where fluid agitation is more vigorous. This water reservoir travels with the swarm, fueling its spreading. Intercellular communication is not required; cells need only grow. PMID:22371567

  17. Water reservoir maintained by cell growth fuels the spreading of a bacterial swarm.

    PubMed

    Wu, Yilin; Berg, Howard C

    2012-03-13

    Flagellated bacteria can swim across moist surfaces within a thin layer of fluid, a means for surface colonization known as swarming. This fluid spreads with the swarm, but how it does so is unclear. We used micron-sized air bubbles to study the motion of this fluid within swarms of Escherichia coli. The bubbles moved diffusively, with drift. Bubbles starting at the swarm edge drifted inward for the first 5 s and then moved outward. Bubbles starting 30 μm from the swarm edge moved inward for the first 20 s, wandered around in place for the next 40 s, and then moved outward. Bubbles starting at 200 or 300 μm from the edge moved outward or wandered around in place, respectively. So the general trend was inward near the outer edge of the swarm and outward farther inside, with flows converging on a region about 100 μm from the swarm edge. We measured cellular metabolic activities with cells expressing a short-lived GFP and cell densities with cells labeled with a membrane fluorescent dye. The fluorescence plots were similar, with peaks about 80 μm from the swarm edge and slopes that mimicked the particle drift rates. These plots suggest that net fluid flow is driven by cell growth. Fluid depth is largest in the multilayered region between approximately 30 and 200 μm from the swarm edge, where fluid agitation is more vigorous. This water reservoir travels with the swarm, fueling its spreading. Intercellular communication is not required; cells need only grow.

  18. Microinjection of acetylcholine into cerebellar fastigial nucleus induces blood depressor response in anesthetized rats.

    PubMed

    Zhang, Changzheng; Luo, Wen; Zhou, Peiling; Sun, Tingzhe

    2016-08-26

    It is well known that the cerebellar fastigial nucleus (FN) is involved in cardiovascular modulation, and has direct evidence of cholinergic activity; however, whether and how acetylcholine (ACh) in the FN modulates blood pressure has not been investigated. In this study, we analyzed mean arterial pressure, maximal change in mean arterial pressure, and the reaction time of blood pressure changes after microinjection of cholinergic reagents into the FN in anesthetized rats. The results showed that ACh evoked a concentration-dependent (10, 30 and 100mM) effect on blood pressure down-regulation. The muscarinic ACh (mACh) receptor antagonist atropine, but not the nicotinic ACh (nACh) receptor antagonist mecamylamine, blocked the ACh-mediated depressor response. The mACh receptor agonist oxotremorine M, rather than nACh receptor agonist nicotine, mimicked the ACh-mediated blood pressure decrease in a dose-dependent manner (10, 30 and 100mM). These results indicate that cholinergic input in the cerebellar FN exerts a depressor effect on systemic blood pressure regulation, and such effects are substantially contributed by mACh rather than nACh receptors, although the precise mechanism concerning the role of mACh receptor in FN-mediated blood pressure modulation remains to be elucidated. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Prospects for in vivo blood velocimetry using acoustic resolution photoacoustic Doppler

    NASA Astrophysics Data System (ADS)

    Brunker, J.; Beard, P.

    2016-03-01

    Acoustic resolution photoacoustic Doppler flowmetry (AR-PAF) is a technique that has the potential to overcome the spatial resolution and depth penetration limitations of current blood flow measuring methods. Previous work has shown the potential of the technique using blood-mimicking phantoms, but it has proved difficult to make accurate measurements in blood, and thus in vivo application has not yet been possible. One explanation for this difficulty is that whole blood is insufficiently heterogeneous. Through experimental measurements in red blood cell suspensions of different concentrations, as well as in whole blood, we provide new insight and evidence that refutes this assertion. We show that the velocity measurement accuracy is influenced by bandlimiting not only due to the detector frequency response, but also due to spatial averaging of absorbers within the detector field-of-view. In addition, there is a detrimental effect of limited light penetration, but this can be mitigated by selecting less attenuated wavelengths of light, and also by employing range-gating signal processing. By careful choice of these parameters as well as the detector centre frequency, bandwidth and field-of-view, it is possible to make AR-PAF measurements in whole blood using transducers with bandwidths in the tens of MHz range. These findings have profound implications for the prospects of making deep tissue measurements of blood flow relevant to the study of microcirculatory abnormalities associated with cancer, diabetes, atherosclerosis and other conditions.

  20. Cerebral hypoxia

    MedlinePlus

    ... support is most important. Treatment involves: Breathing assistance (mechanical ventilation) and oxygen Controlling the heart rate and rhythm Fluids, blood products, or medicines to raise blood pressure ...

  1. Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault-validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer.

    PubMed

    Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela

    2018-05-01

    Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

  2. Microbial load of umbilical cord blood Ureaplasma species and Mycoplasma hominis in preterm prelabor rupture of membranes.

    PubMed

    Kacerovsky, Marian; Pliskova, Lenka; Menon, Ramkumar; Kutova, Radka; Musilova, Ivana; Maly, Jan; Andrys, Ctirad

    2014-11-01

    To evaluate Ureaplasma species and M. hominis DNA in the umbilical cord blood and its correlation with its microbial load in the amniotic fluid, as a measure of microbial burden in fetal inflammatory response and neonatal outcome in pregnancies complicated by preterm prelabor rupture of membranes (pPROM). A retrospective study of 158 women with singleton pregnancies complicated by pPROM between 24(0/7) and 36(6/7) weeks was conducted. Amniotic fluid was obtained from all women by transabdominal amniocentesis, and umbilical cord blood was obtained by venipuncture from umbilical cords immediately after the delivery of the neonates. The Ureaplasma species and M. hominis DNA was quantitated using absolute quantification techniques. Ureaplasma species and M. hominis DNA was identified in 9% of the umbilical cord blood samples. No correlation between the amniotic fluid and umbilical cord blood microbial load was observed. The presence of Ureaplasma species and M. hominis DNA in the umbilical cord blood had no impact on short-term neonatal morbidity. A high microbial load of genital mycoplasma Ureaplasma species DNA in the umbilical cord in pregnancies complicated by pPROM is not associated with a high fetal inflammatory response and is therefore not associated with serious neonatal morbidity.

  3. The safety of peri-articular local anaesthetic injection for patients undergoing total knee replacement with autologous blood transfusion: a randomised trial.

    PubMed

    Wallace, D F; Emmett, S R; Kang, K K; Chahal, G S; Hiskens, R; Balasubramanian, S; McGuinness, K; Parsons, H; Achten, J; Costa, M L

    2012-12-01

    Intra-operative, peri-articular injection of local anaesthesia is an increasingly popular way of controlling pain following total knee replacement. At the same time, the problems associated with allogenic blood transfusion have led to interest in alternative methods for managing blood loss after total knee replacement, including the use of auto-transfusion of fluid from the patient's surgical drain. It is safe to combine peri-articular infiltration with auto-transfusion from the drain. We performed a randomised clinical trial to compare the concentration of local anaesthetic in the blood and in the fluid collected in the knee drain in patients having either a peri-articular injection or a femoral nerve block. Clinically relevant concentrations of local anaesthetic were found in the fluid from the drains of patients having peri-articular injections (4.92 μg/ml (sd 3.151)). However, none of the patients having femoral nerve blockade had detectable levels. None of the patients in either group had clinically relevant concentrations of local anaesthetic in their blood after re-transfusion. The evidence from this study suggests that it is safe to use peri-articular injection in combination with auto-transfusion of blood from peri-articular drains during knee replacement surgery.

  4. Bernoulli's Principle Applied to Brain Fluids: Intracranial Pressure Does Not Drive Cerebral Perfusion or CSF Flow.

    PubMed

    Schmidt, Eric; Ros, Maxime; Moyse, Emmanuel; Lorthois, Sylvie; Swider, Pascal

    2016-01-01

    In line with the first law of thermodynamics, Bernoulli's principle states that the total energy in a fluid is the same at all points. We applied Bernoulli's principle to understand the relationship between intracranial pressure (ICP) and intracranial fluids. We analyzed simple fluid physics along a tube to describe the interplay between pressure and velocity. Bernoulli's equation demonstrates that a fluid does not flow along a gradient of pressure or velocity; a fluid flows along a gradient of energy from a high-energy region to a low-energy region. A fluid can even flow against a pressure gradient or a velocity gradient. Pressure and velocity represent part of the total energy. Cerebral blood perfusion is not driven by pressure but by energy: the blood flows from high-energy to lower-energy regions. Hydrocephalus is related to increased cerebrospinal fluid (CSF) resistance (i.e., energy transfer) at various points. Identification of the energy transfer within the CSF circuit is important in understanding and treating CSF-related disorders. Bernoulli's principle is not an abstract concept far from clinical practice. We should be aware that pressure is easy to measure, but it does not induce resumption of fluid flow. Even at the bedside, energy is the key to understanding ICP and fluid dynamics.

  5. Unusual presentation of anaplastic large cell lymphoma with clinical course mimicking fever of unknown origin and sepsis: autopsy study of five cases.

    PubMed

    Mosunjac, Marina B; Sundstrom, J Bruce; Mosunjac, Mario I

    2008-10-01

    To describe a subset of cases with the unusual clinical and histomorphological presentation of anaplastic large cell lymphoma (ALCL) mimicking fever of unknown origin (FUO) and sepsis. A pathology database was searched using full term Systematized Nomenclature of Medicine codes for ALCL to identify 23ALCL cases from the period 1999-2006. Of those, five cases that did not have a correct premortem diagnosis were further analyzed to elucidate the reasons for delayed and incorrect pre-mortem diagnosis. The analyzed data included clinical presentation, duration of symptoms, duration of hospital stay, premortem presumed cause of death, white blood cell count, platelet count, anion gap and blood pH, liver enzymes (alanine aminotransferase, aspartate aminotransferase, lactate dehydrogenase, alkaline phosphatase), lactate, coagulation tests (prothrombin time, partial thromboplastin time, fibrinogen, D-dimers), microbiology cultures, and radiology and surgical pathology reports. Autopsy reports were reviewed for description of major gross findings, initial clinical diagnosis, and cause of death. Five fatal and pre-mortem unrecognized ALCL cases were characterized by rapid decline, with histologic findings showing predominantly extranodal involvement, intravascular lymphomatosis, and hemophagocytosis. The cases were also characterized by unusual clinical manifestations including a FUO, sepsis, and disseminated intravascular coagulation-like picture, lactic acidosis, hepatosplenomegaly, and absence of significant peripheral adenopathy. There is a distinct group of ALCLs with unique and specific clinical, gross autopsy, and histopathologic findings. Recognition of this clinical variant may facilitate early detection and potentially timely diagnosis and therapy.

  6. The nanoparticle protein corona formed in human blood or human blood fractions.

    PubMed

    Lundqvist, Martin; Augustsson, Cecilia; Lilja, Malin; Lundkvist, Kristoffer; Dahlbäck, Björn; Linse, Sara; Cedervall, Tommy

    2017-01-01

    The protein corona formed around nanoparticles in protein-rich fluids plays an important role for nanoparticle biocompatibility, as found in several studies during the last decade. Biological fluids have complex compositions and the molecular components interact and function together in intricate networks. Therefore, the process to isolate blood or the preparation of blood derivatives may lead to differences in the composition of the identified protein corona around nanoparticles. Here, we show distinct differences in the protein corona formed in whole blood, whole blood with EDTA, plasma, or serum. Furthermore, the ratio between particle surface area to protein concentration influences the detected corona. We also show that the nanoparticle size per se influences the formed protein corona due to curvature effects. These results emphasize the need of investigating the formation and biological importance of the protein corona in the same environment as the nanoparticles are intended for or released into.

  7. "Data characterizing microfabricated human blood vessels created via hydrodynamic focusing".

    PubMed

    DiVito, Kyle A; Daniele, Michael A; Roberts, Steven A; Ligler, Frances S; Adams, André A

    2017-10-01

    This data article provides further detailed information related to our research article titled "Microfabricated Blood Vessels Undergo Neovascularization" (DiVito et al., 2017) [1], in which we report fabrication of human blood vessels using hydrodynamic focusing (HDF). Hydrodynamic focusing with advection inducing chevrons were used in concert to encase one fluid stream within another, shaping the inner core fluid into 'bullseye-like" cross-sections that were preserved through click photochemistry producing streams of cellularized hollow 3-dimensional assemblies, such as human blood vessels (Daniele et al., 2015a, 2015b, 2014, 2016; Roberts et al., 2016) [2], [3], [4], [5], [6]. Applications for fabricated blood vessels span general tissue engineering to organ-on-chip technologies, with specific utility in in vitro drug delivery and pharmacodynamics studies. Here, we report data regarding the construction of blood vessels including cellular composition and cell positioning within the engineered vascular construct as well as functional aspects of the tissues.

  8. Self-separation of blood plasma from whole blood during the capillary flow in microchannel

    NASA Astrophysics Data System (ADS)

    Nunna, Bharath Babu; Zhuang, Shiqiang; Lee, Eon Soo

    2017-11-01

    Self-separation of blood plasma from whole blood in microchannels is of great importance due to the enormous range of applications in healthcare and diagnostics. Blood is a multiphase complex fluid, composed of cells suspended in blood plasma. RBCs are the suspended particles whose shape changes during the flow of blood. The primary constituents of blood are erythrocytes or red blood cells (RBCs), leukocytes or white blood cells (WBCs), thrombocytes or platelets and blood plasma. The existence of RBCs in blood makes the blood a non-Newtonian fluid. The current study of separation of blood plasma from whole blood during self-driven flows in a single microchannel without bifurcation, by enhancing the capillary effects. The change in the capillary effect results in a change in contact angle which directly influences the capillary flow. The flow velocity directly influences the net force acting on the RBCs and influence the separation process. The experiments are performed on the PDMS microchannels with different contact angles by altering the surface characteristics using plasma treatment. The change in the separation length is studied during the capillary flow of blood in microchannel. Bharath Babu Nunna is a researcher in mechanical engineering and implementing the novel and innovative technologies in the biomedical devices to enhance the sensitivity of the disease diagnosis.

  9. Decision-Assist and Closed-Loop Control of Fluid Therapy

    DTIC Science & Technology

    2012-03-30

    achieve target endpoints while reducing fluid needs in experimental models of hemorrhage. During the previous funding cycle, along with our... IABP ) (standard of care blood pressure monitor "gold standard") in cardiac surgical patients to blood pressure recorded by the WVSM. Rational for...WVSM vs Gold standard IABP 2) History of neuropraxia 3) Refusal to consent 4) Failure to obtain radial artery cannulation Ten CPB Patients were

  10. Quantitative assessment of reflux in commercially available needle-free IV connectors.

    PubMed

    Hull, Garret J; Moureau, Nancy L; Sengupta, Shramik

    2018-01-01

    Blood reflux is caused by changes in pressure within intravascular catheters upon connection or disconnection of a syringe or intravenous tubing from a needle-free connector (NFC). Changes in pressure, differing with each brand of NFC, may result in fluid movement and blood reflux that can contribute to intraluminal catheter occlusions and increase the potential for central-line associated bloodstream infections (CLABSI). In this study, 14 NFC brands representing each of the four market-categories of NFCs were selected for evaluation of fluid movement occurring during connection and disconnection of a syringe. Study objectives were to 1) theoretically estimate amount of blood reflux volume in microliters (μL) permitted by each NFC based on exact component measurements, and 2) experimentally measure NFC volume of fluid movement for disconnection reflux of negative, neutral and anti-reflux NFC and fluid movement for connection reflux of positive displacement NFC. The results demonstrated fluid movement/reflux volumes of 9.73 μL to 50.34 μL for negative displacement, 3.60 μL to 10.80 μL for neutral displacement, and 0.02 μL to 1.73 μL for pressure-activated anti-reflux NFC. Separate experiment was performed measuring connection reflux of 18.23 μL to 38.83 μL for positive displacement NFC connectors. This study revealed significant differences in reflux volumes for fluid displacement based on NFC design. While more research is needed on effects of blood reflux in catheters and NFCs, results highlight the need to consider NFCs based on performance of individual connector designs, rather than manufacturer designation of positive, negative and neutral marketing categories for NFCs without anti-reflux mechanisms.

  11. Modeling of heat transfer in a vascular tissue-like medium during an interstitial hyperthermia process.

    PubMed

    Hassanpour, Saeid; Saboonchi, Ahmad

    2016-12-01

    This paper aims to evaluate the role of small vessels in heat transfer mechanisms of a tissue-like medium during local intensive heating processes, for example, an interstitial hyperthermia treatment. To this purpose, a cylindrical tissue with two co- and counter-current vascular networks and a central heat source is introduced. Next, the energy equations of tissue, supply fluid (arterial blood), and return fluid (venous blood) are derived using porous media approach. Then, a 2D computer code is developed to predict the temperature of blood (fluid phase) and tissue (solid phase) by conventional volume averaging method and a more realistic solution method. In latter method, despite the volume averaging the blood of interconnect capillaries is separated from the arterial and venous blood phases. It is found that in addition to blood perfusion rate, the arrangement of vascular network has considerable effects on the pattern and amount of the achieved temperature. In contrast to counter-current network, the co-current network of vessels leads to considerable asymmetric pattern of temperature contours and relocation of heat affected zone along the blood flow direction. However this relocation can be prevented by changing the site of hyperthermia heat source. The results show that the cooling effect of co-current blood vessels during of interstitial heating is more efficient. Despite much anatomical dissimilarities, these findings can be useful in designing of protocols for hyperthermia cancer treatment of living tissue. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Optical phenomena and antifrosting property on biomimetics slippery fluid-infused antireflective films via layer-by-layer comparison with superhydrophobic and antireflective films.

    PubMed

    Manabe, Kengo; Nishizawa, Shingo; Kyung, Kyu-Hong; Shiratori, Seimei

    2014-08-27

    Sophisticated material interfaces generated by natural life forms such as lotus leaves and Nepenthes pitcher plants have exceptional abilities to resolve challenges in wide areas of industry and medicine. The nano- and microstructures inspired by these natural materials can repel various liquids and form self-cleaning coatings. In particular, slippery liquid-infused surfaces are receiving remarkable interest as transparent, nonfouling, and antifrosting synthetic surfaces for solar cells and optical devices. Here we focus on the transparency of lubricant-infused texture on antireflective films fabricated by layer-by-layer self-assembly that decrease light scattering, which is important to maintain device properties. A slippery fluid-infused antireflective film composed of chitin nanofibers less than 50 nm in diameter prevented light scattering at the long-wavelength side by Rayleigh scattering to achieve 97.2% transmittance. Moreover, films composed of the same materials demonstrated three different morphologies: superhydrophilicity with antireflection, superhydrophobicity, and omniphobicity, mimicking the biological structures of moth eyes, lotus leaves, and pitcher plants, respectively. The effect of thermal changes on the ability of each film to prevent frost formation was investigated. The slippery fluid-infused antireflective film showed effective antifrosting behavior.

  13. Simulating shock-bubble interactions at water-gelatin interfaces

    NASA Astrophysics Data System (ADS)

    Adami, Stefan; Kaiser, Jakob; Bermejo-Moreno, Ivan; Adams, Nikolaus

    2016-11-01

    Biomedical problems are often driven by fluid dynamics, as in vivo organisms are usually composed of or filled with fluids that (strongly) affected their physics. Additionally, fluid dynamical effects can be used to enhance certain phenomena or destroy organisms. As examples, we highlight the benign potential of shockwave-driven kidney-stone lithotripsy or sonoporation (acoustic cavitation of microbubbles) to improve drug delivery into cells. During the CTR SummerProgram 2016 we have performed axisymmetric three-phase simulations of a shock hitting a gas bubble in water near a gelatin interface mimicking the fundamental process during sonoporation. We used our multi-resolution finite volume method with sharp interface representation (level-set), WENO-5 shock capturing and interface scale-separation and compared the results with a diffuse-interface method. Qualitatively our simulation results agree well with the reference. Due to the interface treatment the pressure profiles are sharper in our simulations and bubble collapse dynamics are predicted at shorter time-scales. Validation with free-field collapse (Rayleigh collapse) shows very good agreement. The project leading to this application has received funding from the European Research Council (ERC) under the European Union's Horizon 2020 research and innovation programme (Grant agreement No 667483).

  14. Hydrogen gas inhalation inhibits progression to the "irreversible" stage of shock after severe hemorrhage in rats.

    PubMed

    Matsuoka, Tadashi; Suzuki, Masaru; Sano, Motoaki; Hayashida, Kei; Tamura, Tomoyoshi; Homma, Koichiro; Fukuda, Keiichi; Sasaki, Junichi

    2017-09-01

    Mortality of hemorrhagic shock primarily depends on whether or not the patients can endure the loss of circulating volume until radical treatment is applied. We investigated whether hydrogen (H2) gas inhalation would influence the tolerance to hemorrhagic shock and improve survival. Hemorrhagic shock was achieved by withdrawing blood until the mean arterial blood pressure reached 30-35 mm Hg. After 60 minutes of shock, the rats were resuscitated with a volume of normal saline equal to four times the volume of shed blood. The rats were assigned to either the H2 gas (1.3% H2, 26% O2, 72.7% N2)-treated group or the control gas (26% O2, 74% N2)-treated group. Inhalation of the specified gas mixture began at the initiation of blood withdrawal and continued for 2 hours after fluid resuscitation. The survival rate at 6 hours after fluid resuscitation was 80% in H2 gas-treated rats and 30% in control gas-treated rats (p < 0.05). The volume of blood that was removed through a catheter to induce shock was significantly larger in the H2 gas-treated rats than in the control rats. Despite losing more blood, the increase in serum potassium levels was suppressed in the H2 gas-treated rats after 60 minutes of shock. Fluid resuscitation completely restored blood pressure in the H2 gas-treated rats, whereas it failed to fully restore the blood pressure in the control gas-treated rats. At 2 hours after fluid resuscitation, blood pressure remained in the normal range and metabolic acidosis was well compensated in the H2 gas-treated rats, whereas we observed decreased blood pressure and uncompensated metabolic acidosis and hyperkalemia in the surviving control gas-treated rats. H2 gas inhalation delays the progression to irreversible shock. Clinically, H2 gas inhalation is expected to stabilize the subject until curative treatment can be performed, thereby increasing the probability of survival after hemorrhagic shock.

  15. Use of the Esophageal Doppler Machine to help guide the intraoperative management of two children with pheochromocytoma.

    PubMed

    Hack, Henrik

    2006-08-01

    The anesthetic management of pheochromocytoma has been based upon the intraoperative control of blood pressure and fluid balance following adequate preoperative preparation. This can be difficult, especially in the presence of significant comorbidity such as cardiac or renal dysfunction. Two cases of children with pheochromocytoma are reported where the introperative management of fluid balance and blood pressure control were guided by measurement of changes in descending aortic blood flow using an esophageal Doppler probe. The advantages of such a technique compared with more invasive monitors are discussed.

  16. Infectious Prions in the Saliva and Blood of Deer with Chronic Wasting Disease

    NASA Astrophysics Data System (ADS)

    Mathiason, Candace K.; Powers, Jenny G.; Dahmes, Sallie J.; Osborn, David A.; Miller, Karl V.; Warren, Robert J.; Mason, Gary L.; Hays, Sheila A.; Hayes-Klug, Jeanette; Seelig, Davis M.; Wild, Margaret A.; Wolfe, Lisa L.; Spraker, Terry R.; Miller, Michael W.; Sigurdson, Christina J.; Telling, Glenn C.; Hoover, Edward A.

    2006-10-01

    A critical concern in the transmission of prion diseases, including chronic wasting disease (CWD) of cervids, is the potential presence of prions in body fluids. To address this issue directly, we exposed cohorts of CWD-naïve deer to saliva, blood, or urine and feces from CWD-positive deer. We found infectious prions capable of transmitting CWD in saliva (by the oral route) and in blood (by transfusion). The results help to explain the facile transmission of CWD among cervids and prompt caution concerning contact with body fluids in prion infections.

  17. Crystal Structures of HLA-A*0201 Complexed with Melan-A/MART-1[subscript 26(27L)-35] Peptidomimetics Reveal Conformational Heterogeneity and Highlight Degeneracy of T Cell Recognition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Douat-Casassus, Celine; Borbulevych, Oleg; Tarbe, Marion

    2010-10-07

    There is growing interest in using tumor associated antigens presented by class I major histocompatibility complex (MHC-I) proteins as cancer vaccines. As native peptides are poorly stable in biological fluids, researchers have sought to engineer synthetic peptidomimetics with greater biostability. Here, we demonstrate that antigenic peptidomimetics of the Melan-A/MART-1{sub 26(27L)-35} melanoma antigen adopt strikingly different conformations when bound to MHC-I, highlighting the degeneracy of T cell recognition and revealing the challenges associated with mimicking native peptide conformation.

  18. Kelvin-Helmholtz instability in a single-component atomic superfluid

    NASA Astrophysics Data System (ADS)

    Baggaley, A. W.; Parker, N. G.

    2018-05-01

    We demonstrate an experimentally feasible method for generating the classical Kelvin-Helmholtz instability in a single-component atomic Bose-Einstein condensate. By progressively reducing a potential barrier between two counterflowing channels, we seed a line of quantized vortices, which precede to form progressively larger clusters, mimicking the classical roll-up behavior of the Kelvin-Helmholtz instability. This cluster formation leads to an effective superfluid shear layer, formed through the collective motion of many quantized vortices. From this we demonstrate a straightforward method to measure the effective viscosity of a turbulent quantum fluid in a system with a moderate number of vortices, within the range of current experimental capabilities.

  19. Sphenoid sinus mucocele as a cause of isolated pupil-sparing oculomotor nerve palsy mimicking diabetic ophthalmoplegia.

    PubMed

    Mohebbi, Alireza; Jahandideh, Hesam; Harandi, Ali Amini

    2013-12-01

    A 37-year-old woman presented with isolated right-sided oculomotor nerve palsy. Neurologic examination revealed no other disorder. Computed tomography of the paranasal sinuses demonstrated complete opacification of the sphenoid sinus. Dense mucoid fluid was drained from the sphenoid sinus via an endoscopic transseptal sphenoidotomy. A biopsy confirmed the diagnosis of sphenoid sinus mucocele. At follow-up 4 weeks postoperatively, the patient's ocular symptoms were markedly alleviated. Considering rare causes of isolated oculomotor nerve palsy, such as sphenoid sinus mucocele, is important in the differential diagnosis, even in patients with well-known risk factors such as diabetes mellitus.

  20. Furosemide

    MedlinePlus

    ... high blood pressure. Furosemide is used to treat edema (fluid retention; excess fluid held in body tissues) ... or twice a day. When used to treat edema, furosemide may be taken daily or only on ...

  1. Neurotoxicology of the Brain Barrier System: New Implications

    PubMed Central

    Zheng, Wei

    2014-01-01

    The concept of a barrier system in the brain has existed for nearly a century. The barrier that separates the blood from the cerebral interstitial fluid is defined as the blood-brain barrier, while the one that discontinues the circulation between the blood and cerebrospinal fluid is named the blood-cerebrospinal fluid barrier. Evidence in the past decades suggests that brain barriers are subject to toxic insults from neurotoxic chemicals circulating in blood. The aging process and some disease states render barriers more vulnerable to insults arising inside and outside the barriers. The implication of brain barriers in certain neurodegenerative diseases is compelling, although the contribution of chemical-induced barrier dysfunction in the etiology of any of these disorders remains poorly understood. This review examines what is currently understood about brain barrier systems in central nervous system disorders by focusing on chemical-induced neurotoxicities including those associated with nitrobenzenes, N-methyl-D-aspartate, cyclosporin A, pyridostigmine bromide, aluminum, lead, manganese, 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine, and 3-nitropropionic acid. Contemporary research questions arising from this growing understanding show enormous promises for brain researchers, toxicologists, and clinicians. PMID:11778669

  2. Dynamic characteristics and mechatronics model for maglev blood pump

    NASA Astrophysics Data System (ADS)

    Sun, Kun; Chen, Chen

    2017-01-01

    Magnetic bearing system(MBs) has been developed in the new-generation blood pump due to its low power consumption, low blood trauma and high durability. However, MBs for a blood pump were almost influenced by a series of factors such as hemodynamics, rotation speeds and actuator response in working fluids, compared with those applied in other industrial fields. In this study, the dynamic characteristics of MBs in fluid environments, including the influence of the pumping fluid and rotation of the impeller on the radial dynamic model were investigated by measuring the frequency response to sinusoidal excitation upon coils, and the response of radial displacement during a raise in the speed. The excitation tests were conducted under conditions in which the blood pump was levitated in air and water and with or without rotation. The experimental and simulated results indicate that rotations of the impeller affected the characteristics of MBs in water apparently, and the vibration in water was decreased, compared with that in air due to the hydraulic force. During the start-up and rotation, the actuator failed to operate fully and timely, and the voltage supplied can be chosen under the consideration of the rotor displacement and consumption.

  3. Computer Simulations of the Tumor Vasculature: Applications to Interstitial Fluid Flow, Drug Delivery, and Oxygen Supply.

    PubMed

    Welter, Michael; Rieger, Heiko

    2016-01-01

    Tumor vasculature, the blood vessel network supplying a growing tumor with nutrients such as oxygen or glucose, is in many respects different from the hierarchically organized arterio-venous blood vessel network in normal tissues. Angiogenesis (the formation of new blood vessels), vessel cooption (the integration of existing blood vessels into the tumor vasculature), and vessel regression remodel the healthy vascular network into a tumor-specific vasculature. Integrative models, based on detailed experimental data and physical laws, implement, in silico, the complex interplay of molecular pathways, cell proliferation, migration, and death, tissue microenvironment, mechanical and hydrodynamic forces, and the fine structure of the host tissue vasculature. With the help of computer simulations high-precision information about blood flow patterns, interstitial fluid flow, drug distribution, oxygen and nutrient distribution can be obtained and a plethora of therapeutic protocols can be tested before clinical trials. This chapter provides an overview over the current status of computer simulations of vascular remodeling during tumor growth including interstitial fluid flow, drug delivery, and oxygen supply within the tumor. The model predictions are compared with experimental and clinical data and a number of longstanding physiological paradigms about tumor vasculature and intratumoral solute transport are critically scrutinized.

  4. Cytomegalovirus (For Parents)

    MedlinePlus

    ... are done for organ-transplant patients, and blood banks have procedures to help to prevent CMV from passing in blood products. How Is CMV Diagnosed? Doctors diagnose a CMV infection by testing fluid or a tissue sample from a person's throat, pee, blood, or ...

  5. Anti-glomerular basement membrane blood test

    MedlinePlus

    ... the part of the kidney that helps filter waste and extra fluid from the blood. Anti-glomerular basement membrane antibodies are antibodies against this membrane. They can lead to kidney damage. This article describes the blood test to detect these antibodies.

  6. Fluid friction and wall viscosity of the 1D blood flow model.

    PubMed

    Wang, Xiao-Fei; Nishi, Shohei; Matsukawa, Mami; Ghigo, Arthur; Lagrée, Pierre-Yves; Fullana, Jose-Maria

    2016-02-29

    We study the behavior of the pulse waves of water into a flexible tube for application to blood flow simulations. In pulse waves both fluid friction and wall viscosity are damping factors, and difficult to evaluate separately. In this paper, the coefficients of fluid friction and wall viscosity are estimated by fitting a nonlinear 1D flow model to experimental data. In the experimental setup, a distensible tube is connected to a piston pump at one end and closed at another end. The pressure and wall displacements are measured simultaneously. A good agreement between model predictions and experiments was achieved. For amplitude decrease, the effect of wall viscosity on the pulse wave has been shown as important as that of fluid viscosity. Copyright © 2016 Elsevier Ltd. All rights reserved.

  7. Structure-based drug design, synthesis and biological assays of P. falciparum Atg3-Atg8 protein-protein interaction inhibitors

    NASA Astrophysics Data System (ADS)

    Villa, Stefania; Legnani, Laura; Colombo, Diego; Gelain, Arianna; Lammi, Carmen; Bongiorno, Daniele; Ilboudo, Denise P.; McGee, Kellen E.; Bosch, Jürgen; Grazioso, Giovanni

    2018-03-01

    The proteins involved in the autophagy (Atg) pathway have recently been considered promising targets for the development of new antimalarial drugs. In particular, inhibitors of the protein-protein interaction (PPI) between Atg3 and Atg8 of Plasmodium falciparum retarded the blood- and liver-stages of parasite growth. In this paper, we used computational techniques to design a new class of peptidomimetics mimicking the Atg3 interaction motif, which were then synthesized by click-chemistry. Surface plasmon resonance has been employed to measure the ability of these compounds to inhibit the Atg3-Atg8 reciprocal protein-protein interaction. Moreover, P. falciparum growth inhibition in red blood cell cultures was evaluated as well as the cyto-toxicity of the compounds.

  8. Primary central nervous system vasculitis and its mimicking diseases - clinical features, outcome, comorbidities and diagnostic results - A case control study.

    PubMed

    Becker, J; Horn, P A; Keyvani, K; Metz, I; Wegner, C; Brück, W; Heinemann, F M; Schwitalla, J C; Berlit, P; Kraemer, M

    2017-05-01

    To compare clinical features and outcome, imaging characteristics, biopsy results and laboratory findings in a cohort of 69 patients with suspected or diagnosed primary central nervous system vasculitis (PCNSV) in adults; to identify risk factors and predictive features for PCNSV. We performed a case-control-study including 69 patients referred with suspected PCNSV from whom 25 were confirmed by predetermined diagnostic criteria based on biopsy (72%) or angiography (28%). Forty-four patients turned out to have 15 distinct other diagnoses. Clinical and diagnostic data were compared between PCNSV and Non-PCNSV cohorts. Clinical presentation was not able to discriminate between PCNSV and its differential diagnoses. However, a worse clinical outcome was associated with PCNSV (p=0.005). Biopsy (p=0.004), contrast enhancement (p=0.000) or tumour-like mass lesion (p=0.008) in magnetic resonance imaging (MRI), intrathecal IgG increase (p=0.020), normal Duplex findings of cerebral arteries (p=0.022) and conventional angiography (p 0.010) were able to distinguish between the two cohorts. In a cohort of 69 patients with suspected PCNSV, a large number (64%) was misdiagnosed and partly received treatment, since mimicking diseases are very difficult to discriminate. Clinical presentation at manifestation does not help to differentiate PCNSV from its mimicking diseases. MRI and cerebrospinal fluid analysis are unlikely to be normal in PCNSV, though unspecific if pathological. Cerebral angiography and biopsy must complement other diagnostics when establishing the diagnosis in order to avoid misdiagnosis and mistreatment. German clinical trials register: http://drks-neu.uniklinik-freiburg.de/drks_web/, Unique identifier: DRKS00005347. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Property and privacy paradigms of "marketable spit": an ethical and legal counterpart to blood?

    PubMed

    Vernillo, Anthony Thomas; Wolpe, Paul Root

    2010-01-01

    Major advances in the testing of oral fluid (e.g., saliva) may lead to the diagnosis and treatment of previously undiagnosed conditions and may enable dentists to manage oral disease more effectively. Such use of another body fluid, blood, is already well established. Blood is a complex tissue that has been extensively researched and is now used for a wide variety of diagnostic tests. It is also regarded as a form of property with ethical and legal dimensions. If saliva is to fulfill a similar role, it should perhaps be granted those same protections. This paper advances the concept that saliva should be considered a form of property, possibly within personal biological materials law. The emerging potential for the development of marketable products from oral fluids raises the issue of protecting the research participant's ethical and legal rights. In particular, violation of privacy and genetic discrimination may arise from the testing of salivary DNA. Respect for autonomy requires that the clinician inform a patient or research participant about his or her rights to property and privacy as these may pertain to oral fluid.

  10. Raman spectroscopy coupled with advanced statistics for differentiating menstrual and peripheral blood.

    PubMed

    Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; Lednev, Igor K

    2014-01-01

    Body fluids are a common and important type of forensic evidence. In particular, the identification of menstrual blood stains is often a key step during the investigation of rape cases. Here, we report on the application of near-infrared Raman microspectroscopy for differentiating menstrual blood from peripheral blood. We observed that the menstrual and peripheral blood samples have similar but distinct Raman spectra. Advanced statistical analysis of the multiple Raman spectra that were automatically (Raman mapping) acquired from the 40 dried blood stains (20 donors for each group) allowed us to build classification model with maximum (100%) sensitivity and specificity. We also demonstrated that despite certain common constituents, menstrual blood can be readily distinguished from vaginal fluid. All of the classification models were verified using cross-validation methods. The proposed method overcomes the problems associated with currently used biochemical methods, which are destructive, time consuming and expensive. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Interaction between blood and solid particles propagating through a capillary with slip effects.

    PubMed

    Zeeshan, A; Fatima, A; Khalid, F; Bhatti, M M

    2018-04-18

    This article describes the interaction between solid particles and blood propagating through a capillary. A slip condition is considered on the walls of the capillary. The rheological features of the blood are discussed by considering as a two-phase Newtonian fluid model, i.e., the suspension of cells in plasma. A perturbation method is successfully applied to obtain the series solution of the governing coupled differential equations. The series solution for both fluid and particle phase are presented up to second order approximation. The expressions for the velocity and pressure distributions under slip effects are determined within a tube. Furthermore, the current results are beneficial to understand the rheological features of blood which will be helpful to interpret and analyze more complex blood flow models. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Multiphase simulation of blood flow within main thoracic arteries of 8-year-old child with coarctation of the aorta

    NASA Astrophysics Data System (ADS)

    Melka, Bartlomiej; Gracka, Maria; Adamczyk, Wojciech; Rojczyk, Marek; Golda, Adam; Nowak, Andrzej J.; Białecki, Ryszard A.; Ostrowski, Ziemowit

    2017-08-01

    In the research, a numerical Computational Fluid Dynamics (CFD) model of the pulsatile blood flow was created and analysed. A real geometry of aorta and its thoracic branches of an 8-year old patient diagnosed with a congenital heart defect - coarctation of the aorta was used. The inlet boundary condition was implemented as the User Define Function according to measured values of volumetric blood flow. The blood flow was treated as multiphase using Euler-Euler approach. Plasma was set as the primary and dominant fluid phase, with the volume fraction of 0.585. The morphological elements (RBC and WBC) were set as dispersed phases being the remaining volume fraction.

  13. Ultrasonically Encoded Photoacoustic Flowgraphy in Biological Tissue

    NASA Astrophysics Data System (ADS)

    Wang, Lidai; Xia, Jun; Yao, Junjie; Maslov, Konstantin I.; Wang, Lihong V.

    2013-11-01

    Blood flow speed is an important functional parameter. Doppler ultrasound flowmetry lacks sufficient sensitivity to slow blood flow (several to tens of millimeters per second) in deep tissue. To address this challenge, we developed ultrasonically encoded photoacoustic flowgraphy combining ultrasonic thermal tagging with photoacoustic imaging. Focused ultrasound generates a confined heat source in acoustically absorptive fluid. Thermal waves propagate with the flow and are directly visualized in pseudo color using photoacoustic computed tomography. The Doppler shift is employed to calculate the flow speed. This method requires only acoustic and optical absorption, and thus is applicable to continuous fluid. A blood flow speed as low as 0.24mm·s-1 was successfully measured. Deep blood flow imaging was experimentally demonstrated under 5-mm-thick chicken breast tissue.

  14. The role of facilitated diffusion in oxygen transport by cell-free hemoglobins: implications for the design of hemoglobin-based oxygen carriers.

    PubMed

    McCarthy, M R; Vandegriff, K D; Winslow, R M

    2001-08-30

    We compared rates of oxygen transport in an in vitro capillary system using red blood cells (RBCs) and cell-free hemoglobins. The axial PO(2) drop down the capillary was calculated using finite-element analysis. RBCs, unmodified hemoglobin (HbA(0)), cross-linked hemoglobin (alpha alpha-Hb) and hemoglobin conjugated to polyethylene-glycol (PEG-Hb) were evaluated. According to their fractional saturation curves, PEG-Hb showed the least desaturation down the capillary, which most closely matched the RBCs; HbA(0) and alpha alpha-Hb showed much greater desaturation. A lumped diffusion parameter, K*, was calculated based on the Fick diffusion equation with a term for facilitated diffusion. The overall rates of oxygen transfer are consistent with hemoglobin diffusion rates according to the Stokes-Einstein Law and with previously measured blood pressure responses in rats. This study provides a conceptual framework for the design of a 'blood substitute' based on mimicking O(2) transport by RBCs to prevent autoregulatory changes in blood flow and pressure.

  15. Roll-to-roll, shrink-induced superhydrophobic surfaces for antibacterial applications, enhanced point-of-care detection, and blood anticoagulation

    NASA Astrophysics Data System (ADS)

    Nokes, Jolie McLane

    Superhydrophobic (SH) surfaces are desirable because of their unique anti-wetting behavior. Fluid prefers to bead up (contact angle >150°) and roll off (contact angle hysteresis <10°) a SH surface because micro- and nanostructure features trap air pockets. Fluid only adheres to the peaks of the structures, causing minimal adhesion to the surface. Here, shrink-induced SH plastics are fabricated for a plethora of applications, including antibacterial applications, enhanced point-of-care (POC) detection, and reduced blood coagulation. Additionally, these purely structural SH surfaces are achieved in a roll-to-roll (R2R) platform for scalable manufacturing. Because their self-cleaning and water resistant properties, structurally modified SH surfaces prohibit bacterial growth and obviate bacterial chemical resistance. Antibacterial properties are demonstrated in a variety of SH plastics by preventing gram-negative Escherichia coli (E. coli) bacterial growth >150x compared to flat when fluid is rinsed and >20x without rinsing. Therefore, a robust and stable means to prevent bacteria growth is possible. Next, protein in urine is detected using a simple colorimetric output by evaporating droplets on a SH surface. Contrary to evaporation on a flat surface, evaporation on a SH surface allows fluid to dramatically concentrate because the weak adhesion constantly decreases the footprint area. On a SH surface, molecules in solution are confined to a footprint area 8.5x smaller than the original. By concentrating molecules, greater than 160x improvements in detection sensitivity are achieved compared to controls. Utility is demonstrated by detecting protein in urine in the pre-eclampsia range (150-300microgmL -1) for pregnant women. Further, SH surfaces repel bodily fluids including blood, urine, and saliva. Importantly, the surfaces minimize blood adhesion, leading to reduced blood coagulation without the need for anticoagulants. SH surfaces have >4200x and >28x reduction of blood residue area and volume compared to the non-structured controls of the same material. In addition, blood clotting area is reduced >5x using whole blood directly from the patient. In this study, biocompatible SH surfaces are achieved using commodity shrink-wrap film and are scaled up for R2R manufacturing. The purely structural modification negates complex and expensive post processing, and SH features are achieved in commercially-available and FDA-approved plastics.

  16. Sodium blood test

    MedlinePlus

    ... Lithium Nonsteroidal anti-inflammatory drugs (NSAIDs) Water pills (diuretics) DO NOT stop taking any medicine before talking ... salt or fluid Receive intravenous (IV) fluids Take diuretics (water pills) or certain other medicines, including the ...

  17. Ebola virus disease

    MedlinePlus

    ... body fluids of infected animals Contact with infected bats Ebola does NOT spread through: Air Water Food ... who has died from Ebola. Avoid contact with bats and nonhuman primates or blood, fluids, and raw ...

  18. Blood-mimicking delivery in polygonal structure of inner quadrupletip microneedle with valveless micro-pump

    NASA Astrophysics Data System (ADS)

    Ibrahim, M. D.; Yunos, Y. S.; Rigit, A. R. H.; Mohtadzar, N. A. A.; Watanabe, N.; Sunami, Y.; Rahman, M. R. A.; Wong, L. K.; Mohtar, M. Z.

    2017-04-01

    This paper presents a titanium quadrupletip micro-needle integrated with a micro-pump with different inner designs, length and diameter of the micro-channels to measure and maximize the velocity flow in the micro-needle as blood delivered into human body. Titanium is used as the material of the micro-needle which are also the common material in manufacturing of micro-needle. The advancement of micro-needle technologies is improved in penetrating human outermost skin, stratum corneum and further to human blood vessels. The micro-needles with channel inner design of circular, square, hexagon, and dodecagon with quadruple tip designs are drawn with inner diameter parameter of 150μm and 100μm with two different channel length which are 10mm and 25mm. The characteristics of blood delivery in geometrically changed inner designs affect the output velocity in microneedle when the micropump is operating. The results showed that, when it is pumped at 0.04m/s, the blood velocity improved by 5.6% than when the pump is increased by 30% of its capacity. This is due to the backflow generated in the micropump.

  19. Small-molecule WNK inhibition regulates cardiovascular and renal function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yamada, Ken; Park, Hyi-Man; Rigel, Dean F.

    The With-No-Lysine (K) (WNK) kinases play a critical role in blood pressure regulation and body fluid and electrolyte homeostasis. Herein, we introduce the first orally bioavailable pan-WNK-kinase inhibitor, WNK463, that exploits unique structural features of the WNK kinases for both affinity and kinase selectivity. In rodent models of hypertension, WNK463 affects blood pressure and body fluid and electro-lyte homeostasis, consistent with WNK-kinase-associated physiology and pathophysiology.

  20. Fluid Mechanics, Arterial Disease, and Gene Expression.

    PubMed

    Tarbell, John M; Shi, Zhong-Dong; Dunn, Jessilyn; Jo, Hanjoong

    2014-01-01

    This review places modern research developments in vascular mechanobiology in the context of hemodynamic phenomena in the cardiovascular system and the discrete localization of vascular disease. The modern origins of this field are traced, beginning in the 1960s when associations between flow characteristics, particularly blood flow-induced wall shear stress, and the localization of atherosclerotic plaques were uncovered, and continuing to fluid shear stress effects on the vascular lining endothelial) cells (ECs), including their effects on EC morphology, biochemical production, and gene expression. The earliest single-gene studies and genome-wide analyses are considered. The final section moves from the ECs lining the vessel wall to the smooth muscle cells and fibroblasts within the wall that are fluid me chanically activated by interstitial flow that imposes shear stresses on their surfaces comparable with those of flowing blood on EC surfaces. Interstitial flow stimulates biochemical production and gene expression, much like blood flow on ECs.

  1. A magnetic fluid seal for rotary blood pumps: Long-term performance in liquid

    NASA Astrophysics Data System (ADS)

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of a MF seal, however, has been reported to decrease in liquids. We have developed a MF seal that has a 'shield' mechanism and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. The seal was perfect against a pressure of 150 mmHg in a continuous flow of 4.0 L/min for 275 days and against a pressure of 175 mmHg in a continuous flow of 3.9 L/min for 217 days. We have developed a MF seal that works in liquid against pressure mostly used clinically. The magnetic fluid seal is promising as a shaft seal for rotary blood pumps.

  2. Co-isolation of Bartonella henselae and Bartonella vinsonii subsp. berkhoffii from blood, joint and subcutaneous seroma fluids from two naturally infected dogs.

    PubMed

    Diniz, Pedro Paulo Vissotto de Paiva; Wood, Michael; Maggi, Ricardo G; Sontakke, Sushama; Stepnik, Matt; Breitschwerdt, Edward B

    2009-09-18

    This report describes the clinical presentation, isolation and treatment of two dogs naturally infected with Bartonella henselae and Bartonella vinsonii subsp. berkhoffii. Chronic and progressive polyarthritis was the primary complaint for dog #1, from which B. henselae and B. vinsonii subsp. berkhoffii were cultured on three independent occasions from blood and joint fluid samples, despite administration of nearly 4 months of non-consecutive antibiotic therapy. A clinically atypical and progressively severe trauma-associated seroma was the primary complaint for dog #2, from which B. henselae and B. vinsonii subsp. berkhoffii were isolated from serum, blood and seroma fluid. Dogs can be co-infected with two Bartonella spp. and infection with these organisms should not be ruled out if specific antibodies are not detected. Specialized culture techniques should be used for isolation and to assess antibiotic efficacy.

  3. A C-terminal cyclic 8-13 neurotensin fragment analog appears less exposed to neprilysin when it crosses the blood-brain barrier than the cerebrospinal fluid-brain barrier in mice.

    PubMed

    Van Kemmel, F M; Dubuc, I; Bourdel, E; Fehrentz, J A; Martinez, J; Costentin, J

    1996-10-11

    A C-terminal cyclic 8-13 neurotensin fragment analog. JMV 1193, a direct agonist of central neurotensin receptors, is able to cross both the cerebrospinal fluid-brain barrier and the blood-brain barrier. When administered intracerebroventricularly (i.c.v.), its hypothermic effect was potentiated by the enkephalinase inhibition induced either by thiorphan (simultaneous intracerebroventricular administration of 10 micrograms) or by the thiorphan prodrug. acetorphan (intravenous (i.v.) administration of 10 mg/kg). Such a potentiation was not observed when both JMV 1193 and acetorphan were administered intravenously. Therefore it appears that the sensitivity of JMV 1193 to enkephalinase depends on its route of administration. It is exposed to this peptidase after i.c.v. injection (when crossing the cerebrospinal fluid-brain barrier), while it is not after i.v. administration (when crossing the blood-brain barrier).

  4. Principles of physics in surgery: the laws of flow dynamics physics for surgeons - Part 1.

    PubMed

    Srivastava, Anurag; Sood, Akshay; Joy, S Parijat; Woodcock, John

    2009-08-01

    In the field of medicine and surgery many principles of physics find numerous applications. In this article we have summarized some prominent applications of the laws of fluid mechanics and hydrodynamics in surgery. Poiseuille's law sets the limits of isovolaemic haemodilution, enumerates limiting factors during fluid resuscitation and is a guiding principle in surgery for vascular stenoses. The equation of continuity finds use in non-invasive measurement of blood flow. Bernoulli's theorem explains the formation of post-stenotic dilatation. Reynolds number explains the origin of murmurs, haemolysis and airflow disturbances. Various forms of oxygen therapy are a direct application of the gas laws. Doppler effect is used in ultrasonography to find the direction and velocity of blood flow. In this first part of a series of articles we describe some applications of the laws of hydrodynamics governing the flow of blood and other body fluids.

  5. Bianchi I cosmology in the presence of a causally regularized viscous fluid

    NASA Astrophysics Data System (ADS)

    Montani, Giovanni; Venanzi, Marta

    2017-07-01

    We analyze the dynamics of a Bianchi I cosmology in the presence of a viscous fluid, causally regularized according to the Lichnerowicz approach. We show how the effect induced by shear viscosity is still able to produce a matter creation phenomenon, meaning that also in the regularized theory we address, the Universe is emerging from a singularity with a vanishing energy density value. We discuss the structure of the singularity in the isotropic limit, when bulk viscosity is the only retained contribution. We see that, as far as viscosity is not a dominant effect, the dynamics of the isotropic Universe possesses the usual non-viscous power-law behaviour but in correspondence to an effective equation of state, depending on the bulk viscosity coefficient. Finally, we show that, in the limit of a strong non-thermodynamical equilibrium of the Universe mimicked by a dominant contribution of the effective viscous pressure, a power-law inflation behaviour of the Universe appears, the cosmological horizons are removed and a significant amount of entropy is produced.

  6. Challenges of ECG monitoring and ECG interpretation in dialysis units.

    PubMed

    Poulikakos, Dimitrios; Malik, Marek

    Patients on hemodialysis (HD) suffer from high cardiovascular morbidity and mortality due to high rates of coronary artery disease and arrhythmias. Electrocardiography (ECG) is often performed in the dialysis units as part of routine clinical assessment. However, fluid and electrolyte changes have been shown to affect all ECG morphologies and intervals. ECG interpretation thus depends on the time of the recording in relation to the HD session. In addition, arrhythmias during HD are common, and dialysis-related ECG artifacts mimicking arrhythmias have been reported. Studies using advanced ECG analyses have examined the impact of the HD procedure on selected repolarization descriptors and heart rate variability indices. Despite the challenges related to the impact of the fluctuant fluid and electrolyte status on conventional and advanced ECG parameters, further research in ECG monitoring during dialysis has the potential to provide clinically meaningful and practically useful information for diagnostic and risk stratification purposes. Crown Copyright © 2016. Published by Elsevier Inc. All rights reserved.

  7. The Effects of High Level Magnesium Dialysis/Substitution Fluid on Magnesium Homeostasis under Regional Citrate Anticoagulation in Critically Ill

    PubMed Central

    Los, Ferdinand; Brodska, Helena

    2016-01-01

    Background The requirements for magnesium (Mg) supplementation increase under regional citrate anticoagulation (RCA) because citrate acts by chelation of bivalent cations within the blood circuit. The level of magnesium in commercially available fluids for continuous renal replacement therapy (CRRT) may not be sufficient to prevent hypomagnesemia. Methods Patients (n = 45) on CRRT (2,000 ml/h, blood flow (Qb) 100 ml/min) with RCA modality (4% trisodium citrate) using calcium free fluid with 0.75 mmol/l of Mg with additional magnesium substitution were observed after switch to the calcium-free fluid with magnesium concentration of 1.50 mmol/l (n = 42) and no extra magnesium replenishment. All patients had renal indications for CRRT, were treated with the same devices, filters and the same postfilter ionized calcium endpoint (<0.4 mmol/l) of prefilter citrate dosage. Under the high level Mg fluid the Qb, dosages of citrate and CRRT were consequently escalated in 9h steps to test various settings. Results Median balance of Mg was -0.91 (-1.18 to -0.53) mmol/h with Mg 0.75 mmol/l and 0.2 (0.06–0.35) mmol/h when fluid with Mg 1.50 mmol/l was used. It was close to zero (0.02 (-0.12–0.18) mmol/h) with higher blood flow and dosage of citrate, increased again to 0.15 (-0.11–0.25) mmol/h with 3,000 ml/h of high magnesium containing fluid (p<0.001). The arterial levels of Mg were mildly increased after the change for high level magnesium containing fluid (p<0.01). Conclusions Compared to ordinary dialysis fluid the mildly hypermagnesemic fluid provided even balances and adequate levels within ordinary configurations of CRRT with RCA and without a need for extra magnesium replenishment. Trial Registration ClinicalTrials.gov Identifier: NCT01361581 PMID:27391902

  8. [Analysis of factors related to the number of mesenchymal stem cells derived from synovial fluid of the temporomandibular joint].

    PubMed

    Sun, Y P; Zheng, Y H; Zhang, Z G

    2017-06-09

    Objective: To analyze related factors on the number of mesenchymal stem cells in the synovial fluid of the temporomandibular joint (TMJ) and provide an research basis for understanding of the source and biological role of mesenchymal stem cells derived from synovial fluid in TMJ. Methods: One hundred and twenty-two synovial fluid samples from 91 temporomandibular disorders (TMD) patients who visited in Department of TMJ Center, Guanghua School of Stomatology, Hospital of Stomatology, Sun Yat-sen University from March 2013 to December 2013 were collected in this study, and 6 TMJ synovial fluid samples from 6 normal volunteers who were studying in the North Campus of Sun Yat-sen University were also collected, so did their clinical information. Then the relation between the number of mesenchymal stem cells derived from synovial fluid and the health status of the joints, age of donor, disc perforation, condylar bony destruction, blood containing and visual analogue scale score of pain were investigated using Mann-Whitney U test and Spearman rank correlation test. Results: The number of mesenchymal stem cells derived from synovial fluid had no significant relation with visual analogue scale score of pain ( r= 0.041, P= 0.672), blood containing ( P= 0.063), condylar bony destruction ( P= 0.371). Linear correlation between the number of mesenchymal stem cells derived from synovial fluid and age of donor was very week ( r= 0.186, P= 0.043). The number of mesenchymal stem cells up-regulated when the joint was in a disease state ( P= 0.001). The disc perforation group had more mesenchymal stem cells in synovial fluid than without disc perforation group ( P= 0.042). Conclusions: The number of mesenchymal stem cells derived from synovial fluid in TMJ has no correlation with peripheral blood circulation and condylar bony destruction, while has close relation with soft tissue structure damage of the joint.

  9. Viscous flow past a collapsible channel as a model for self-excited oscillation of blood vessels.

    PubMed

    Tang, Chao; Zhu, Luoding; Akingba, George; Lu, Xi-Yun

    2015-07-16

    Motivated by collapse of blood vessels for both healthy and diseased situations under various circumstances in human body, we have performed computational studies on an incompressible viscous fluid past a rigid channel with part of its upper wall being replaced by a deformable beam. The Navier-Stokes equations governing the fluid flow are solved by a multi-block lattice Boltzmann method and the structural equation governing the elastic beam motion by a finite difference method. The mutual coupling of the fluid and solid is realized by the momentum exchange scheme. The present study focuses on the influences of the dimensionless parameters controlling the fluid-structure system on the collapse and self-excited oscillation of the beam and fluid dynamics downstream. The major conclusions obtained in this study are described as follows. The self-excited oscillation can be intrigued by application of an external pressure on the elastic portion of the channel and the part of the beam having the largest deformation tends to occur always towards the end portion of the deformable wall. The blood pressure and wall shear stress undergo significant variations near the portion of the greatest oscillation. The stretching motion has the most contribution to the total potential elastic energy of the oscillating beam. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Cryoglobulinemia

    MedlinePlus

    ... is also used. In this his procedure, blood plasma is taken out of blood circulation and abnormal cryoglobulin antibody proteins are removed. The plasma is replaced by fluid, protein, or donated plasma. ...

  11. Measuring Time-Averaged Blood Pressure

    NASA Technical Reports Server (NTRS)

    Rothman, Neil S.

    1988-01-01

    Device measures time-averaged component of absolute blood pressure in artery. Includes compliant cuff around artery and external monitoring unit. Ceramic construction in monitoring unit suppresses ebb and flow of pressure-transmitting fluid in sensor chamber. Transducer measures only static component of blood pressure.

  12. Structural Characteristics and Corrosion Behavior of Bio-Degradable Zn-Li Alloys in Stent Application

    NASA Astrophysics Data System (ADS)

    Zhao, Shan

    Zinc has begun to be studied as a bio-degradable material in recent years due to its excellent corrosion rate and optimal biocompatibility. Unfortunately, pure Zn's intrinsic ultimate tensile strength (UTS; below 120 MPa) is lower than the benchmark (about 300 MPa) for cardiovascular stent materials, raising concerns about sufficient strength to support the blood vessel. Thus, modifying pure Zn to improve its mechanical properties is an important research topic. In this dissertation project, a new Zn-Li alloy has been developed to retain the outstanding corrosion behavior from Zn while improving the mechanical characteristics and uniform biodegradation once it is implanted into the artery of Sprague-Dawley rats. The completed work includes: Manufactured Zn-Li alloy ingots and sheets via induction vacuum casting, melt spinning, hot rolling deformation, and wire electro discharge machining (wire EDM) technique; processed alloy samples using cross sectioning, mounting, etching and polishing technique; • Characterized alloy ingots, sheets and wires using hardness and tensile test, XRD, BEI imaging, SEM, ESEM, FTIR, ICP-OES and electrochemical test; then selected the optimum composition for in vitro and in vivo experiments; • Mimicked the degradation behavior of the Zn-Li alloy in vitro using simulated body fluid (SBF) and explored the relations between corrosion rate, corrosion products and surface morphology with changing compositions; • Explanted the Zn-Li alloy wire in abdominal aorta of rat over 12 months and studied its degradation mechanism, rate of bioabsorption, cytotoxicity and corrosion product migration from histological analysis.

  13. Diagnosis and management of fluid overload in heart failure and cardio-renal syndrome: the "5B" approach.

    PubMed

    Ronco, Claudio; Kaushik, Manish; Valle, Roberto; Aspromonte, Nadia; Peacock, W Frank

    2012-01-01

    Cardio-Renal syndrome may occur as a result of either primarily renal or cardiac dysfunction. This complex interaction requires a tailored approach to manage the underlying pathophysiology while optimizing the patient's symptoms and thus providing the best outcomes. Patients often are admitted to the hospital for signs and symptoms of congestion and fluid overload is the most frequent cause of subsequent re-admission. Fluid management is of paramount importance in the strategy of treatment for heart failure patients. Adequate fluid status should be obtained but a target value should be set according to objective indicators and biomarkers. Once the fluid excess is identified, a careful prescription of fluid removal by diuretics or extracorporeal therapies must be made. While delivering these therapies, adequate monitoring should be performed to prevent unwanted effects such as worsening of renal function or other complications. There is a very narrow window of optimal hydration for heart failure patients. Overhydration can result in myocardial stretching and potential decompensation. Inappropriate dehydration or relative reduction of circulating blood volume may result in distant organ damage caused by inadequate perfusion. We suggest consideration of the "5B" approach. This stands for balance of fluids (reflected by body weight), blood pressure, biomarkers, bioimpedance vector analysis, and blood volume. Addressing these parameters ensures that the most important issues affecting symptoms and outcomes are addressed. Furthermore, the patient is receiving the best possible care while avoiding unwanted side effects of the treatment. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Choroid plexus glutathione peroxidases are instrumental in protecting the brain fluid environment from hydroperoxides during postnatal development.

    PubMed

    Saudrais, Elodie; Strazielle, Nathalie; Ghersi-Egea, Jean-Francois

    2018-06-27

    Hydrogen peroxide, released at low physiological concentration, is involved in different cell signaling pathways during brain development. When released at supraphysiological concentrations in brain fluids following an inflammatory, hypoxic or toxic stress, it can initiate lipid peroxidation, protein and nucleic acid damage and contribute to long-term neurological impairment associated with perinatal diseases. We found high glutathione peroxidase and glutathione reductase enzymatic activities in both lateral and fourth ventricle choroid plexus tissue isolated from developing rats, in comparison to the cerebral cortex and liver. Consistent with these, a high protein expression of glutathione peroxidases 1 and 4 was observed in choroid plexus epithelial cells, which form the blood-cerebrospinal fluid barrier. Live choroid plexuses isolated from newborn rats were highly efficient in detoxifying H2O2 from mock cerebrospinal fluid, illustrating the capacity of the choroid plexuses to control H2O2 concentration in the ventricular system of the brain. We used a differentiated cellular model of the blood-cerebrospinal fluid barrier coupled to kinetic and inhibition analyses to show that glutathione peroxidases are more potent than catalase to detoxify extracellular H2O2 at concentrations up to 250 µM. The choroidal cells also formed an enzymatic barrier preventing blood-borne hydroperoxides to reach the cerebrospinal fluid. These data point out the choroid plexuses as key structures in the control of hydroperoxide levels in the cerebral fluid environment during development, at a time when the protective glial cell network is still immature. Glutathione peroxidases are the main effectors of this choroidal hydroperoxide inactivation.

  15. Computational Analysis of Human Blood Flow

    NASA Astrophysics Data System (ADS)

    Panta, Yogendra; Marie, Hazel; Harvey, Mark

    2009-11-01

    Fluid flow modeling with commercially available computational fluid dynamics (CFD) software is widely used to visualize and predict physical phenomena related to various biological systems. In this presentation, a typical human aorta model was analyzed assuming the blood flow as laminar with complaint cardiac muscle wall boundaries. FLUENT, a commercially available finite volume software, coupled with Solidworks, a modeling software, was employed for the preprocessing, simulation and postprocessing of all the models.The analysis mainly consists of a fluid-dynamics analysis including a calculation of the velocity field and pressure distribution in the blood and a mechanical analysis of the deformation of the tissue and artery in terms of wall shear stress. A number of other models e.g. T branches, angle shaped were previously analyzed and compared their results for consistency for similar boundary conditions. The velocities, pressures and wall shear stress distributions achieved in all models were as expected given the similar boundary conditions. The three dimensional time dependent analysis of blood flow accounting the effect of body forces with a complaint boundary was also performed.

  16. Multilayer nanoparticles with a magnetite core and a polycation inner shell as pH-responsive carriers for drug delivery

    NASA Astrophysics Data System (ADS)

    Guo, Miao; Yan, Yu; Liu, Xiaozhou; Yan, Husheng; Liu, Keliang; Zhang, Hongkai; Cao, Youjia

    2010-03-01

    Nanocarriers with multilayer core-shell architecture were prepared by coating a superparamagnetic Fe3O4 core with a triblock copolymer. The first block of the copolymer formed the biocompatible outermost shell of the nanocarrier. The second block that contains amino groups and hydrophobic moiety formed the inner shell. The third block bound tightly onto the Fe3O4 core. Chlorambucil (an anticancer agent) and indomethacin (an anti-inflammation agent), each containing a carboxyl group and a hydrophobic moiety, were loaded into the amino-group-containing inner shell by a combination of ionic and hydrophobic interactions. The release rate of the loaded drugs was slow at pH 7.4, mimicking the blood environment, whereas the release rate increased significantly at acidic pH, mimicking the intracellular conditions in the endosome/lysosome. This can be attributed to the disruption of the ionic bond caused by protonation of the carboxylate anion of the drugs and the swelling of the inner shell caused by protonation of the amino groups.

  17. Acute Toxic Neuropathy Mimicking Guillain Barre Syndrome

    PubMed Central

    Jalal, Muhammed Jasim Abdul; Fernandez, Shirley Joan; Menon, Murali Krishna

    2015-01-01

    Case: A 30 year old male presented with numbness of palms and soles followed by weakness of upper limbs and lower limbs of 5 days duration, which was ascending and progressive. Three months back he was treated for oral and genital ulcers with oral steroids. His ulcers improved and shifted to indigenous medication. His clinical examination showed polyneuropathy. CSF study did not show albuminocytological dissociation. Nerve conduction study showed demyelinating polyneuropathy. His blood samples and the ayurvedic drug samples were sent for toxicological analysis. Inference: Acute toxic neuropathy - Arsenic PMID:25811007

  18. Biomimetic postcapillary expansions for enhancing rare blood cell separation on a microfluidic chip†

    PubMed Central

    Jain, Abhishek

    2013-01-01

    Blood cells naturally auto-segregate in postcapillary venules, with the erythrocytes (red blood cells, RBCs) aggregating near the axis of flow and the nucleated cells (NCs)—which include leukocytes, progenitor cells and, in cancer patients, circulating tumor cells—marginating toward the vessel wall. We have used this principle to design a microfluidic device that extracts nucleated cells (NCs) from whole blood. Fabricated using polydimethylsiloxane (PDMS) soft lithography, the biomimetic cell extraction device consists of rectangular microchannels that are 20–400 μm wide, 11 μm deep and up to 2 cm long. The key design feature is the use of repeated expansions/contractions of triangular geometry mimicking postcapillary venules, which enhance margination and optimize the extraction. The device operates on unprocessed whole blood and is able to extract 94 ± 4.5% of NCs with 45.75 ± 2.5-fold enrichment in concentration at a rate of 5 nl s−1. The device eliminates the need to preprocess blood via centrifugation or RBC lysis, and is ready to be implemented as the initial stage of lab-on-a-chip devices that require enriched nucleated cells. The potential downstream applications are numerous, encompassing all preclinical and clinical assays that operate on enriched NC populations and include on-chip flow cytometry PMID:21773633

  19. Investigation of the fluidity of biological fluids with a PDDTBN spin probe

    NASA Astrophysics Data System (ADS)

    Severcan, Feride; Acar, Berrin; Gökalp, Saadet

    1997-06-01

    The aim of this study is to ascertain whether the electron spin resonance technique using perdeutero-di- t-butyl nitroxide (PDDTBN) as a spin probe is able to monitor relative fluidity changes occurring in body fluids, such as blood and parotid saliva, according to different physiological conditions. The present study reveals that the spin probe PDDTBN is able to monitor the fluidity changes in parotid saliva related to habitual smoking, and in whole blood related to the estradiol level. The rotational correlation time of the spin probe and the local viscosity values of the parotid saliva and blood have been reported.

  20. Hormonal regulation of fluid and electrolyte metabolism in zero-g and bedrest

    NASA Technical Reports Server (NTRS)

    Vernikos, Joan

    1991-01-01

    The study of man in spaceflight has consistently indicated changes in fluid and electrolyte balance. Sodium (Na), Potassium (K), and Calcium (Ca) excretion are increased, accompanied by changes in the levels and responsiveness of adrenal hormones and the sympathetic nervous system (SNS). These hormones and neurohumors are critical to the regulation of blood pressure, blood flow, and blood volume. The primary objectives of the research conducted under this task have been to use -6 deg head down bedrest (BR) as the analog to spaceflight, to determine the long term changes in these systems, their relationship to orthostatic tolerance, and to develop and test suitable countermeasures.

  1. Needleless connectors substantially reduce flow of crystalloid and red blood cells during rapid infusion.

    PubMed

    Lehn, Robert A; Gross, Jeffrey B; McIsaac, Joseph H; Gipson, Keith E

    2015-04-01

    Although needleless connectors (NC) are frequently used in the perioperative setting, the potential of modern NCs to slow delivery of IV fluids has not been thoroughly studied. We examined flow characteristics of 5 NC models during pressurized delivery of crystalloid and banked red blood cells from a Level 1 warmer through various IV catheters. Crystalloid flow rates were reduced by 29% to 85% from control in catheters >18 gauge, while red blood cell flow reductions ranged from 22% to 76% in these catheters (all P < 0.0050). We suggest that practitioners consider eliminating NCs when large IV catheters are inserted for rapid fluid administration.

  2. Assessment of Spectral Doppler in Preclinical Ultrasound Using a Small-Size Rotating Phantom

    PubMed Central

    Yang, Xin; Sun, Chao; Anderson, Tom; Moran, Carmel M.; Hadoke, Patrick W.F.; Gray, Gillian A.; Hoskins, Peter R.

    2013-01-01

    Preclinical ultrasound scanners are used to measure blood flow in small animals, but the potential errors in blood velocity measurements have not been quantified. This investigation rectifies this omission through the design and use of phantoms and evaluation of measurement errors for a preclinical ultrasound system (Vevo 770, Visualsonics, Toronto, ON, Canada). A ray model of geometric spectral broadening was used to predict velocity errors. A small-scale rotating phantom, made from tissue-mimicking material, was developed. True and Doppler-measured maximum velocities of the moving targets were compared over a range of angles from 10° to 80°. Results indicate that the maximum velocity was overestimated by up to 158% by spectral Doppler. There was good agreement (<10%) between theoretical velocity errors and measured errors for beam-target angles of 50°–80°. However, for angles of 10°–40°, the agreement was not as good (>50%). The phantom is capable of validating the performance of blood velocity measurement in preclinical ultrasound. PMID:23711503

  3. Cirrhosis

    MedlinePlus

    ... weight loss Nausea or belly pain Small, red spider-like blood vessels on the skin As liver ... result of too much fluid Reddened palms Red spider-like blood vessels on the skin Small testicles ...

  4. Mechanism of Headward Fluid Shift During Exposure To Microgravity

    NASA Technical Reports Server (NTRS)

    Hargens, Alan R.; Parazynski, Scott E.; Watenpaugh, Donald E.; Aratow, Michael; Murthy, Gita; Kawai, Yasuaki

    1994-01-01

    A prominent feature of early cardiovascular adaptation to the microgravity of space flight is a shift of blood and tissue fluid from the lower body to the upper body. Symptoms of this fluid shift include facial edema, nasal congestion, and headache. Normally on Earth, the human body is exposed to hydrostatic (gravitational) blood pressure gradients during upright posture. In this posture, mean arterial pressures at head, heart, and foot levels are approximately 70, 100, and 200 mm Hg, respectively. Theoretically, all hydrostatic pressures within arteries and veins are lost during exposure to microgravity so that mean arterial pressure in all regions of the body is uniform and approximately equal to that at heart level (100 mm Hg). Acute studies of 60 head-down tilt (simulated microgravity on Earth) indicate that facial edema is caused by: 1) elevation of capillary blood pressure from 28 to 34 mm Hg, 2) reduction of blood colloid osmotic pressure 22 to 18 mm Hg, and 3) 50% increase of blood perfusion in tissues of the head. Furthermore, as compared to microvasculature in the feet, microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise within lower body negative pressure provides equivalent or greater physiologic stress as compared to similar upright exercise on Earth.

  5. 21 CFR 884.1660 - Transcervical endoscope (amnioscope) and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... visualize the fetus or amniotic fluid and to sample fetal blood or amniotic fluid. This generic type of device may include obturators, instruments used through an operating channel, light sources and cables...

  6. The characterization of exosomes from biological fluids of patients with different types of cancer

    NASA Astrophysics Data System (ADS)

    Yunusova, N. V.; Tamkovich, S. N.; Stakheeva, M. N.; Grigor'eva, A. A.; Somov, A. K.; Tugutova, E. A.; Kolomiets, L. A.; Molchanov, S. V.; Afanas'ev, S. G.; Kakurina, G. V.; Choinzonov, E. L.; Kondakova, I. V.

    2017-09-01

    Exosomes are extracellular membrane structures involved in many physiological and pathological processes including cancerogenesis and metastasis. The purpose of the study was to isolate, identify and analyze the total content of exosomes in biological fluids. The exosomes from the plasma and ascites samples of the patients with ovarian cancer, from the blood plasma of the patients with colorectal and head and neck squamous cell cancer as well as from the blood plasma of healthy donors were characterized using transmission electron microscopy and flow cytometry. The subpopulations of the exosomes in the biological fluids of the patients with different types of cancer were similar, but the protein concentrations of exosomes were different. In this paper we present the methodological approaches allowing us to obtain high quality exosome preparations from biological fluids.

  7. Defining Dogma: Quantifying Crystalloid Hemodilution in a Prospective Randomized Control Trial with Blood Donation as a Model for Hemorrhage.

    PubMed

    Ross, Samuel Wade; Christmas, A Britton; Fischer, Peter E; Holway, Haley; Seymour, Rachel; Huntington, Ciara R; Heniford, B Todd; Sing, Ronald F

    2018-06-04

    The concept of hemodilution after blood loss and crystalloid infusion is a surgical maxim that remains unproven in humans. We sought to quantify the effect of hemodilution after crystalloid administration in voluntary blood donors as a model for acute hemorrhage. A prospective, randomized control trial was conducted in conjunction with community blood drives. Donors were randomized to receive no IV fluid(noIVF), two liters normal saline(NS), or two liters lactated ringers(LR) after blood donation. Blood samples were taken before donation of 500 mL of blood, immediately after donation, and following IV fluid administration. Hemoglobin(Hgb) was measured at each time point. Hgb between time points were compared between groups using standard statistical tests and the Bonferroni correction for multiple comparisons. Statistical significance was set at p≤0.0167. Of 165 patients consented, 157 patients completed the study. Average pre-donation Hgb was 14.3 g/dL. There was no difference in the mean Hgb levels after blood donation between the three groups(p>0.05). Compared to the control group, there was a significant drop in Hgb in the crystalloid infused groups from the post-donation level to post-resuscitation(13.2 vs 12.1 vs 12.2 g/dL, p<0.0001). A formula was created to predict hemoglobin levels from a given estimated blood loss(EBL) and volume replacement(VR): Hemodilution Hgb=(MeanPre-donation Hgb - hemorrhage Hgb drop - equilibration hemoglobin drop - resuscitation Hgb drop)=MeanPre-donation Hgb - [(EBL/TBV)*l] - [(EBL/TBV)*h] - [(VR/TBV)*r], l = 5.111g/dL = blood loss coefficient, h=6.722 g/dL=equilibration coefficient, r= 2.617g/dL= resuscitation coefficient. This study proves the concept of hemodilution and derived a mathematical relationship between blood loss and resuscitation. This data may help to estimate response of hemoglobin levels to blood loss and fluid resuscitation in clinical practice. Copyright © 2018. Published by Elsevier Inc.

  8. In-line Microwave Warmer for Blood and Intravenous Fluids.

    DTIC Science & Technology

    1989-12-14

    circuit was designed and tested. This circuit uses a digitally controlled optically coupled Triac , a thyristor device, which acts as a switch to allow...three sites of the circuit : Inlet Port of Heating Chamber Interior Path of Heating Chamber Outlet Port of Heating Chamber 4) Feedback Control Mechanism...accomplished through use of a closed loop test circuit depicted in Figure 1-2. This test circuit can be used to heat iv fluids or blood on a continuous

  9. A Computer Simulation Model of Fluid Flow Through a Channel with Constriction

    DTIC Science & Technology

    2013-06-01

    separation in blood flow rather than mechanical pressure. While it is very unlikely that there is a net electric charge generated by blood flow, there...gate 8 valve as measured by a mechanical flowmeter. The height of the fluid in the upper reservoir was maintained at a constant level by means of an...Gamani Karunasiri Scott Denardo THIS PAGE INTENTIONALLY LEFT BLANK i REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting

  10. Computed Flow Through An Artificial Heart And Valve

    NASA Technical Reports Server (NTRS)

    Rogers, Stuart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    NASA technical memorandum discusses computations of flow of blood through artificial heart and through tilting-disk artificial heart valve. Represents further progress in research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478). One purpose of research to exploit advanced techniques of computational fluid dynamics and capabilities of supercomputers to gain understanding of complicated internal flows of viscous, essentially incompressible fluids like blood. Another to use understanding to design better artificial hearts and valves.

  11. Positional differences in reactive hyperemia provide insight into initial phase of exercise hyperemia.

    PubMed

    Jasperse, Jeffrey L; Shoemaker, J Kevin; Gray, Eric J; Clifford, Philip S

    2015-09-01

    Studies have reported a greater blood flow response to muscle contractions when the limb is below the heart compared with above the heart, and these results have been interpreted as evidence for a skeletal muscle pump contribution to exercise hyperemia. If limb position affects the blood flow response to other vascular challenges such as reactive hyperemia, this interpretation may not be correct. We hypothesized that the magnitude of reactive hyperemia would be greater with the limb below the heart. Brachial artery blood flow (Doppler ultrasound) and blood pressure (finger-cuff plethysmography) were measured in 10 healthy volunteers. Subjects lay supine with one arm supported in two different positions: above or below the heart. Reactive hyperemia was produced by occlusion of arterial inflow for varying durations: 0.5 min, 1 min, 2 min, or 5 min in randomized order. Peak increases in blood flow were 77 ± 11, 178 ± 24, 291 ± 25, and 398 ± 33 ml/min above the heart and 96 ± 19, 279 ± 62, 550 ± 60, and 711 ± 69 ml/min below the heart (P < 0.05). Thus a standard stimulus (vascular occlusion) elicited different responses depending on limb position. To determine whether these differences were due to mechanisms intrinsic to the arterial wall, a second set of experiments was performed in which acute intraluminal pressure reduction for 0.5 min, 1 min, 2 min, or 5 min was performed in isolated rat soleus feed arteries (n = 12). The magnitude of dilation upon pressure restoration was greater when acute pressure reduction occurred from 85 mmHg (mimicking pressure in the arm below the heart; 28.3 ± 7.9, 37.5 ± 5.9, 55.1 ± 9.9, and 68.9 ± 8.6% dilation) than from 48 mmHg (mimicking pressure in the arm above the heart; 20.8 ± 4.8, 22.6 ± 4.4, 31.2 ± 5.8, and 49.2 ± 7.1% dilation). These data support the hypothesis that arm position differences in reactive hyperemia are at least partially mediated by mechanisms intrinsic to the arterial wall. Overall, these results suggest the need to reevaluate studies employing positional changes to examine muscle pump influences on exercise hyperemia. Copyright © 2015 the American Physiological Society.

  12. Flow interactions with cells and tissues: cardiovascular flows and fluid-structure interactions. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008, Pasadena, California.

    PubMed

    Friedman, Morton H; Krams, Rob; Chandran, Krishnan B

    2010-03-01

    Interactions between flow and biological cells and tissues are intrinsic to the circulatory, respiratory, digestive and genitourinary systems. In the circulatory system, an understanding of the complex interaction between the arterial wall (a living multi-component organ with anisotropic, nonlinear material properties) and blood (a shear-thinning fluid with 45% by volume consisting of red blood cells, platelets, and white blood cells) is vital to our understanding of the physiology of the human circulation and the etiology and development of arterial diseases, and to the design and development of prosthetic implants and tissue-engineered substitutes. Similarly, an understanding of the complex dynamics of flow past native human heart valves and the effect of that flow on the valvular tissue is necessary to elucidate the etiology of valvular diseases and in the design and development of valve replacements. In this paper we address the influence of biomechanical factors on the arterial circulation. The first part presents our current understanding of the impact of blood flow on the arterial wall at the cellular level and the relationship between flow-induced stresses and the etiology of atherosclerosis. The second part describes recent advances in the application of fluid-structure interaction analysis to arterial flows and the dynamics of heart valves.

  13. In vivo effects of carprofen, deracoxib, and etodolac on prostanoid production in blood, gastric mucosa, and synovial fluid in dogs with chronic osteoarthritis.

    PubMed

    Sessions, John K; Reynolds, Lisa R; Budsberg, Steven C

    2005-05-01

    To evaluate in vivo activity of carprofen, deracoxib, and etodolac on prostanoid production in several target tissues in dogs with chronic osteoarthritis. 8 dogs with chronic unilateral osteoarthritis of the stifle joint. Each dog received carprofen, deracoxib, or etodolac for 10 days with a 30- to 60-day washout period between treatments. On days 0, 3, and 10, prostaglandin (PG) E2 concentrations were measured in lipopolysaccharide-stimulated blood, synovial fluid, and gastric mucosal biopsy specimens; PGE1 concentrations were measured in gastric mucosal biopsy specimens; and thromboxane B2 (TXB2) was evaluated in blood. Carprofen and deracoxib significantly suppressed PGE2 concentrations in blood at days 3 and 10, compared with baseline, whereas etodolac did not. None of the drugs significantly suppressed TXB2 concentrations in blood or gastric PGE1 synthesis at any time point. All 3 drugs significantly decreased gastric synthesis of PGE2 at day 3 but not day 10 of each treatment period. All 3 drugs decreased synovial fluid PGE2 concentrations in the affected and unaffected stifle joints at days 3 and 10. Results indicate that carprofen and deracoxib act in vivo on target tissues as COX-1-sparing drugs by sparing gastric PGE1 and PGE2 synthesis and production of TXB2 by platelets. Etodolac also appears to be COX-1 sparing but may have variable effects on COX-2 depending on the tissue. In gastric mucosa and synovial fluid, there were no significant differences in PG production between compounds at recommended concentrations.

  14. Concerted spatial-frequency and polarization-phase filtering of laser images of polycrystalline networks of blood plasma smears

    NASA Astrophysics Data System (ADS)

    Ushenko, Yu A.

    2012-11-01

    The complex technique of concerted polarization-phase and spatial-frequency filtering of blood plasma laser images is suggested. The possibility of obtaining the coordinate distributions of phases of linearly and circularly birefringent protein networks of blood plasma separately is presented. The statistical (moments of the first to fourth orders) and scale self-similar (logarithmic dependences of power spectra) structure of phase maps of different types of birefringence of blood plasma of two groups of patients-healthy people (donors) and those suffering from rectal cancer-is investigated. The diagnostically sensitive parameters of a pathological change of the birefringence of blood plasma polycrystalline networks are determined. The effectiveness of this technique for detecting change in birefringence in the smears of other biological fluids in diagnosing the appearance of cholelithiasis (bile), operative differentiation of the acute and gangrenous appendicitis (exudate), and differentiation of inflammatory diseases of joints (synovial fluid) is shown.

  15. Computational Fluid Dynamics Analysis of Thrombosis Potential In Left Ventricular Assist Device Drainage Cannulae

    PubMed Central

    Fraser, Katharine H; Zhang, Tao; Taskin, M Ertan; Griffith, Bartley P; Wu, Zhongjun J

    2010-01-01

    Cannulation is necessary when blood is removed from the body, for example in hemodialysis, cardiopulmonary bypass, blood oxygenators, and ventricular assist devices. Artificial blood contacting surfaces are prone to thrombosis, especially in the presence of stagnant or recirculating flow. In this work, computational fluid dynamics was used to investigate the blood flow fields in three clinically available cannulae (Medtronic DLP 12, 16 and 24 F), used as drainage for pediatric circulatory support, and to calculate parameters which may be indicative of thrombosis potential. The results show that using the 24 F cannula below flow rates of about 0.75 l/min produces hemodynamic conditions which may increase the risk of blood clotting within the cannula. No reasons are indicated for not using the 12 or 16 F cannulae with flow rates between 0.25 and 3.0 l/min. PMID:20400890

  16. Detection and quantification of intraperitoneal fluid using electrical impedance tomography.

    PubMed

    Sadleir, R J; Fox, R A

    2001-04-01

    A prototype electrical impedance tomography system was evaluated prior to its use for the detection of intraperitoneal bleeding, with the assistance of patients undergoing continuous ambulatory peritoneal dialysis (CAPD). The system was sensitive enough to detect small amounts of dialysis fluid appearing in subtractive images over short time periods. Uniform sensitivity to blood appearing anywhere within the abdominal cavity was produced using a post-reconstructive filter that corrected for changes in apparent resistivity of anomalies with their radial position. The image parameter used as an indication of fluid quantity, the resistivity index, varied approximately linearly with the quantity of fluid added. A test of the system's response to the introduction of conductive fluid out of the electrode plane (when a blood-equivalent fluid was added to the stomach) found that the sensitivity of the system was about half that observed in the electrode plane. Breathing artifacts were found to upset quantitative monitoring of intraperitoneal bleeding, but only on time scales short compared with the fluid administration rate. Longer term breathing changes, such as those due to variations in the functional residual capacity of the lungs, should ultimately limit the sensitivity over long time periods.

  17. Dialysis -- hemodialysis

    MedlinePlus

    ... Dialysis treats end-stage kidney failure . It removes waste from your blood when your kidneys can no ... toxins and extra fluid from your blood. If waste products build up in your body, it can ...

  18. A Randomized, Double Crossover Study to Investigate the Influence of Saline Infusion on Sleep Apnea Severity in Men

    PubMed Central

    Yadollahi, Azadeh; Gabriel, Joseph M.; White, Laura H.; Taranto Montemurro, Luigi; Kasai, Takatoshi; Bradley, T. Douglas

    2014-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is commoner in patients with fluid-retaining states than in those without fluid retention, in men than in women, and worsens with aging. In men, OSA severity is related to the amount of fluid shifting out of the legs overnight, but a cause-effect relationship is not established. Our objective was to test the hypothesis that mimicking fluid overload during sleep would increase severity of OSA more in older (≥ 40 years) than in younger men (< 40 years). Design: Randomized, single-blind, double crossover study. Setting: Research sleep laboratory. Patients or Participants: Seven older and 10 younger men with non-severe or no sleep apnea, matched for body mass index. Interventions: During the control arm, normal saline was infused to keep the vein open. During intervention, subjects received an intravenous bolus of normal saline (22 mL/kg body weight) after sleep onset while they were wearing compression stockings to prevent fluid accumulation in the legs. Measurements and Results: Compared to younger men, infusion of similar amounts of saline in older men caused a greater increase in neck circumference (P < 0.05) and in the AHI (32.2 ± 22.1 vs. 2.2 ± 7.1, P = 0.002). Conclusions: Older men are more susceptible to the adverse effects of intravenous fluid loading on obstructive sleep apnea severity than younger men. This may be due to age-related differences in the amount of fluid accumulating in the neck or upper airway collapsibility in response to intravenous fluid loading. These possibilities remain to be tested in future studies. Citation: Yadollahi A, Gabriel JM, White LH, Taranto Montemurro L, Kasai T, Bradley TD. A randomized, double crossover study to investigate the influence of saline infusion on sleep apnea severity in men. SLEEP 2014;37(10):1699-1705. PMID:25197812

  19. A numerical study of blood flow using mixture theory

    PubMed Central

    Wu, Wei-Tao; Aubry, Nadine; Massoudi, Mehrdad; Kim, Jeongho; Antaki, James F.

    2014-01-01

    In this paper, we consider the two dimensional flow of blood in a rectangular microfluidic channel. We use Mixture Theory to treat this problem as a two-component system: One component is the red blood cells (RBCs) modeled as a generalized Reiner–Rivlin type fluid, which considers the effects of volume fraction (hematocrit) and influence of shear rate upon viscosity. The other component, plasma, is assumed to behave as a linear viscous fluid. A CFD solver based on OpenFOAM® was developed and employed to simulate a specific problem, namely blood flow in a two dimensional micro-channel, is studied. Finally to better understand this two-component flow system and the effects of the different parameters, the equations are made dimensionless and a parametric study is performed. PMID:24791016

  20. A numerical study of blood flow using mixture theory.

    PubMed

    Wu, Wei-Tao; Aubry, Nadine; Massoudi, Mehrdad; Kim, Jeongho; Antaki, James F

    2014-03-01

    In this paper, we consider the two dimensional flow of blood in a rectangular microfluidic channel. We use Mixture Theory to treat this problem as a two-component system: One component is the red blood cells (RBCs) modeled as a generalized Reiner-Rivlin type fluid, which considers the effects of volume fraction (hematocrit) and influence of shear rate upon viscosity. The other component, plasma, is assumed to behave as a linear viscous fluid. A CFD solver based on OpenFOAM ® was developed and employed to simulate a specific problem, namely blood flow in a two dimensional micro-channel, is studied. Finally to better understand this two-component flow system and the effects of the different parameters, the equations are made dimensionless and a parametric study is performed.

  1. Hormonal regulation of fluid and electrolyte metabolism during periods of headward fluid shifts

    NASA Technical Reports Server (NTRS)

    Keil, Lanny C.; Severs, W. B.; Thrasher, T.; Ramsay, D. J.

    1991-01-01

    In the broadest sense, this project evaluates how spaceflight induced shifts of blood and interstitial fluids into the thorax affect regulation by the central nervous system (CNS) of fluid-electrolyte hormone secretion. Specifically, it focuses on the role of hormones related to salt/water balance and their potential function in the control of intracranial pressure and cerebrospinal fluid (CSF) composition. Fluid-electrolyte status during spaceflight gradually equilibrates, with a reduction in all body fluid compartments. Related to this is the cardiovascular deconditioning of spaceflight which is manifested upon return to earth as orthostatic intolerance.

  2. Effects of walking in deep venous thrombosis: a new integrated solid and fluid mechanics model.

    PubMed

    López, Josep M; Fortuny, Gerard; Puigjaner, Dolors; Herrero, Joan; Marimon, Francesc; Garcia-Bennett, Josep

    2017-05-01

    Deep venous thrombosis (DVT) is a common disease. Large thrombi in venous vessels cause bad blood circulation and pain; and when a blood clot detaches from a vein wall, it causes an embolism whose consequences range from mild to fatal. Walking is recommended to DVT patients as a therapeutical complement. In this study the mechanical effects of walking on a specific patient of DVT were simulated by means of an unprecedented integration of 3 elements: a real geometry, a biomechanical model of body tissues, and a computational fluid dynamics study. A set of computed tomography images of a patient's leg with a thrombus in the popliteal vein was employed to reconstruct a geometry model. Then a biomechanical model was used to compute the new deformed geometry of the vein as a function of the fiber stretch level of the semimembranosus muscle. Finally, a computational fluid dynamics study was performed to compute the blood flow and the wall shear stress (WSS) at the vein and thrombus walls. Calculations showed that either a lengthening or shortening of the semimembranosus muscle led to a decrease of WSS levels up to 10%. Notwithstanding, changes in blood viscosity properties or blood flow rate may easily have a greater impact in WSS. Copyright © 2016 John Wiley & Sons, Ltd.

  3. Analysis of non-Newtonian effects within an aorta-iliac bifurcation region.

    PubMed

    Iasiello, Marcello; Vafai, Kambiz; Andreozzi, Assunta; Bianco, Nicola

    2017-11-07

    The geometry of the arteries at or near arterial bifurcation influences the blood flow field, which is an important factor affecting arteriogenesis. The blood can act sometimes as a non-Newtonian fluid. However, many studies have argued that for large and medium arteries, the blood flow can be considered to be Newtonian. In this work a comprehensive investigation of non-Newtonian effects on the blood fluid dynamic behavior in an aorta-iliac bifurcation is presented. The aorta-iliac geometry is reconstructed with references to the values reported in Shah et al. (1978); the 3D geometrical model consists of three filleted cylinders of different diameters. Governing equations with the appropriate boundary conditions are solved with a finite-element code. Different rheological models are used for the blood flow through the lumen and detailed comparisons are presented for the aorta-iliac bifurcation. Results are presented in terms of the velocity profiles in the bifurcation zone and Wall Shear Stress (WSS) for different sides of the bifurcation both for male and female geometries, showing that the Newtonian fluid assumption can be made without any particular loss in terms of accuracy with respect to the other more complex rheological models. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Comparison of Proteins in Whole Blood and Dried Blood Spot Samples by LC/MS/MS

    NASA Astrophysics Data System (ADS)

    Chambers, Andrew G.; Percy, Andrew J.; Hardie, Darryl B.; Borchers, Christoph H.

    2013-09-01

    Dried blood spot (DBS) sampling methods are desirable for population-wide biomarker screening programs because of their ease of collection, transportation, and storage. Immunoassays are traditionally used to quantify endogenous proteins in these samples but require a separate assay for each protein. Recently, targeted mass spectrometry (MS) has been proposed for generating highly-multiplexed assays for biomarker proteins in DBS samples. In this work, we report the first comparison of proteins in whole blood and DBS samples using an untargeted MS approach. The average number of proteins identified in undepleted whole blood and DBS samples by liquid chromatography (LC)/MS/MS was 223 and 253, respectively. Protein identification repeatability was between 77 %-92 % within replicates and the majority of these repeated proteins (70 %) were observed in both sample formats. Proteins exclusively identified in the liquid or dried fluid spot format were unbiased based on their molecular weight, isoelectric point, aliphatic index, and grand average hydrophobicity. In addition, we extended this comparison to include proteins in matching plasma and serum samples with their dried fluid spot equivalents, dried plasma spot (DPS), and dried serum spot (DSS). This work begins to define the accessibility of endogenous proteins in dried fluid spot samples for analysis by MS and is useful in evaluating the scope of this new approach.

  5. CFD modeling of an ultrasonic separator for the removal of lipid particles from pericardial suction blood.

    PubMed

    Trippa, Giuliana; Ventikos, Yiannis; Taggart, David P; Coussios, Constantin-C

    2011-02-01

    A computational fluid dynamics (CFD) model is presented to simulate the removal of lipid particles from blood using a novel ultrasonic quarter-wavelength separator. The Lagrangian-Eulerian CFD model accounts for conservation of mass and momentum, for the presence of lipid particles of a range of diameters, for the acoustic force as experienced by the particles in the blood, as well as for gravity and other particle-fluid interaction forces. In the separator, the liquid flows radially inward within a fluid chamber formed between a disc-shaped transducer and a disc-shaped reflector. Following separation of the lipid particles, blood exits the separator axially through a central opening on the disc-shaped reflector. Separator diameters studied varied between 12 and 18 cm, and gap sizes between the discs of 600 μm, 800 μm and 1 mm were considered. Results show a strong effect of residence time of the particles within the chamber on the separation performance. Different separator configurations were identified, which could give a lipid removal performance of 95% or higher when processing 62.5 cm (3)/min of blood. The developed model provides a design method for the selection of geometric and operating parameters for the ultrasonic separator.

  6. Correlations between Different Heavy Metals in Diverse Body Fluids: Studies of Human Semen Quality

    PubMed Central

    Mínguez-Alarcón, Lidia; Mendiola, Jaime; Roca, Manuela; López-Espín, José J.; Guillén, José J.; Moreno, José M.; Moreno-Grau, Stella; Martínez-García, María J.; Vergara-Juárez, Nuria; Elvira-Rendueles, Belén; García-Sánchez, Antonio; Ten, Jorge; Bernabeu, Rafael; Torres-Cantero, Alberto M.

    2012-01-01

    It has been hypothesized that exposure to heavy metals may impair male reproduction. To measure the effect produced by low doses of heavy metals on semen parameters, it is necessary to clarify in which body fluids those measurements must be performed. Sixty-one men attending infertility clinics participated in our study. Concentrations of lead, cadmium, and mercury were measured in whole blood, blood plasma, and seminal plasma using spectroanalytical and electrochemical methods. Semen analyses were performed according to World Health Organization criteria. For statistical analysis, Spearman's rank correlations, mean comparison tests, and discriminant analysis were calculated. Significant correlations between the measured concentrations of the three heavy metals in the same biological fluids were observed. However, no similar relationship was seen when comparing the concentrations in different body fluids of the same metal. According to our results and previous publications, seminal plasma might be the best body fluid for assessing impairment of human semen parameters. PMID:22312326

  7. Passage of delta sleep-inducing peptide (DSIP) across the blood-cerebrospinal fluid barrier

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zlokovic, B.V.; Segal, M.B.; Davson, H.

    1988-05-01

    Unidirectional flux of /sup 125/I-labeled DSIP at the blood-tissue interface of the blood-cerebrospinal fluid (CSF) barrier was studied in the perfused in situ choroid plexuses of the lateral ventricles of the sheep. Arterio-venous loss of /sup 125/I-radioactivity suggested a low-to-moderate permeability of the choroid epithelium to the intact peptide from the blood side. A saturable mechanism with Michaelis-Menten type kinetics with high affinity and very low capacity (approximate values: Kt = 5.0 +/- 0.4 nM; Vmax = 272 +/- 10 fmol.min-1) was demonstrated at the blood-tissue interface of the choroid plexus. The clearance of DSIP from the ventricles during ventriculo-cisternalmore » perfusion in the rabbit indicated no significant flux of the intact peptide out of the CSF. The results suggest that DSIP crosses the blood-CSF barrier, while the system lacks the specific mechanisms for removal from the CSF found with most, if not all, amino acids and several peptides.« less

  8. The detection and discrimination of human body fluids using ATR FT-IR spectroscopy.

    PubMed

    Orphanou, Charlotte-Maria; Walton-Williams, Laura; Mountain, Harry; Cassella, John

    2015-07-01

    Blood, saliva, semen and vaginal secretions are the main human body fluids encountered at crime scenes. Currently presumptive tests are routinely utilised to indicate the presence of body fluids, although these are often subject to false positives and limited to particular body fluids. Over the last decade more sensitive and specific body fluid identification methods have been explored, such as mRNA analysis and proteomics, although these are not yet appropriate for routine application. This research investigated the application of ATR FT-IR spectroscopy for the detection and discrimination of human blood, saliva, semen and vaginal secretions. The results demonstrated that ATR FT-IR spectroscopy can detect and distinguish between these body fluids based on the unique spectral pattern, combination of peaks and peak frequencies corresponding to the macromolecule groups common within biological material. Comparisons with known abundant proteins relevant to each body fluid were also analysed to enable specific peaks to be attributed to the relevant protein components, which further reinforced the discrimination and identification of each body fluid. Overall, this preliminary research has demonstrated the potential for ATR FT-IR spectroscopy to be utilised in the routine confirmatory screening of biological evidence due to its quick and robust application within forensic science. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Effects of 30 day simulated microgravity and recovery on fluid homeostasis and renal function in the rat

    NASA Technical Reports Server (NTRS)

    Tucker, Bryan J.; Mendonca, Margarida M.

    1995-01-01

    Transition from a normal gravitational environment to that of microgravity eventually results in decreased plasma and blood volumes, increasing with duration of exposure to microgravity. This loss of vascular fluid is presumably due to negative fluid and electrolyte balance and most likely contributes to the orthostatic intolerance associated with the return to gravity. The decrease in plasma volume is presumed to be a reflection of a concurrent decrease in extracellular fluid volume with maintenance of normal plasma-interstitial fluid balance. In addition, the specific alterations in renal function contributing to these changes in fluid and electrolyte homeostasis are potentially responding to neuro-humoral signals that are not consistent with systemic fluid volume status. We have previously demonstrated an early increase in both glomerular filtration rate and extracellular fluid volume and that this decreases towards control values by 7 days of simulated microgravity. However, longer duration studies relating these changes to plasma volume alterations and the response to return to orthostasis have not been fully addressed. Male Wistar rats were chronically cannulated, submitted to 30 days heat-down tilt (HDT) and followed for 7 days after return to orthostasis from HDT. Measurements of renal function and extracellular and blood volumes were performed in the awake rat.

  10. Prediction of blood pressure and blood flow in stenosed renal arteries using CFD

    NASA Astrophysics Data System (ADS)

    Jhunjhunwala, Pooja; Padole, P. M.; Thombre, S. B.; Sane, Atul

    2018-04-01

    In the present work an attempt is made to develop a diagnostive tool for renal artery stenosis (RAS) which is inexpensive and in-vitro. To analyse the effects of increase in the degree of severity of stenosis on hypertension and blood flow, haemodynamic parameters are studied by performing numerical simulations. A total of 16 stenosed models with varying degree of stenosis severity from 0-97.11% are assessed numerically. Blood is modelled as a shear-thinning, non-Newtonian fluid using the Carreau model. Computational Fluid Dynamics (CFD) analysis is carried out to compute the values of flow parameters like maximum velocity and maximum pressure attained by blood due to stenosis under pulsatile flow. These values are further used to compute the increase in blood pressure and decrease in available blood flow to kidney. The computed available blood flow and secondary hypertension for varying extent of stenosis are mapped by curve fitting technique using MATLAB and a mathematical model is developed. Based on these mathematical models, a quantification tool is developed for tentative prediction of probable availability of blood flow to the kidney and severity of stenosis if secondary hypertension is known.

  11. Needle Stick Injuries, Sharp Injuries and other Occupational Exposures to Blood and Body Fluids among Health Care Workers in a general hospital in Sarajevo, Bosnia and Herzegovina.

    PubMed

    Musa, Sanjin; Peek-Asa, Corinne; Young, Tracy; Jovanovic, Nina

    2014-01-01

    Health Professional exposures of health care workers (HCW) to potentially infective blood and body fluids presents a serious health threat, including hepatitis B, hepatitis C and HIV transmission. This study was conducted to assess the risk for and reporting of needle stick injuries, sharp injuries and other occupational exposures of health care workers in a large healthcare center in Sarajevo. This cross-sectional survey was conducted in May 2013. The study target population included all hospital health care workers who had a high potential for exposure. The estimated sample size was 48 physicians, 132 nurses/technicians and 30 auxiliary personnel. During their career, 124 (63.3%) HCW reported exposures to blood and body fluids. In total, needle stick injuries (66.1%) were the most common source of exposure, followed by contact with intact skin (12.1%) and cut with sharp object (11.3%). Only 43 (35.5%) reported any of these exposures to health authorities during their career. The odds of exposure to needle stick injuries and other occupational exposures to blood and bodily fluids were significantly higher among medical nurses/technicians (AOR=4.98, 95%CI=1.52-16,1) and auxiliary (AOR=4.30, 95% CI=1.07-17.34) personnel when compared to physicians. HCW in the operation room, intervention ambulance and laboratory (AOR=3.73, 95%CI=1.43-9.72) had higher odds of exposure than workers in the ambulatory departments. Needle stick Injuries, Sharp Injuries and other Occupational Exposures to Blood and Body Fluids among health care workers are underestimated hazard. Especially, for HCW who work in operation room/interventional ambulance. There is a need for preventive programs for HCW and further work on the establishment of an effective surveillance system.

  12. Detecting and collecting traces of semen and blood from outdoor crime scenes using crime scene dogs and presumptive tests.

    PubMed

    Skalleberg, A G; Bouzga, M M

    2016-07-01

    In 2009, the Norwegian police academy educated their first crime scene dogs, trained to locate traces of seminal fluid and blood in outdoor and indoor crime scenes. The Department of Forensic Biology was invited to take part in this project to educate the police in specimen collection and presumptive testing. We performed tests where seminal fluid was deposited on different outdoor surfaces from between one hour to six days, and blood on coniferous ground from between one hour to two days. For both body fluids the tests were performed with three different volumes. The crime scene dogs located the stains, and acid phosphatase/tetrabasebariumperoxide was used as presumptive tests before collection for microscopy and DNA analysis. For seminal fluid the dogs were able to locate all stains for up to two days and only the largest volume after four days. The presumptive tests confirmed the dog's detection. By microscopy we were able to detect spermatozoa for the smallest volumes up to 32h, and for the largest volume up to 4 days, and the DNA results are in correlation to these findings. For blood all the stains were detected by the dogs, except the smallest volume of blood after 32h. The presumptive tests confirmed the dog's detection. We were able to get DNA results for most stains in the timeframe 1-48h with the two largest volumes. The smallest volume shows diversities between the parallels, with no DNA results after 24h. These experiments show that it is critical that body fluids are collected within a timeframe to be able to get a good DNA result, preferably within the first 24-48h. Other parameters that should be taken into account are the weather conditions, type of surfaces and specimen collection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  13. An innovative design for cardiopulmonary resuscitation manikins based on a human-like thorax and embedded flow sensors.

    PubMed

    Thielen, Mark; Joshi, Rohan; Delbressine, Frank; Bambang Oetomo, Sidarto; Feijs, Loe

    2017-03-01

    Cardiopulmonary resuscitation manikins are used for training personnel in performing cardiopulmonary resuscitation. State-of-the-art cardiopulmonary resuscitation manikins are still anatomically and physiologically low-fidelity designs. The aim of this research was to design a manikin that offers high anatomical and physiological fidelity and has a cardiac and respiratory system along with integrated flow sensors to monitor cardiac output and air displacement in response to cardiopulmonary resuscitation. This manikin was designed in accordance with anatomical dimensions using a polyoxymethylene rib cage connected to a vertebral column from an anatomical female model. The respiratory system was composed of silicon-coated memory foam mimicking lungs, a polyvinylchloride bronchus and a latex trachea. The cardiovascular system was composed of two sets of latex tubing representing the pulmonary and aortic arteries which were connected to latex balloons mimicking the ventricles and lumped abdominal volumes, respectively. These balloons were filled with Life/form simulation blood and placed inside polyether foam. The respiratory and cardiovascular systems were equipped with flow sensors to gather data in response to chest compressions. Three non-medical professionals performed chest compressions on this manikin yielding data corresponding to force-displacement while the flow sensors provided feedback. The force-displacement tests on this manikin show a desirable nonlinear behaviour mimicking chest compressions during cardiopulmonary resuscitation in humans. In addition, the flow sensors provide valuable data on the internal effects of cardiopulmonary resuscitation. In conclusion, scientifically designed and anatomically high-fidelity designs of cardiopulmonary resuscitation manikins that embed flow sensors can improve physiological fidelity and provide useful feedback data.

  14. Timing, predictors, and progress of third space fluid accumulation during preliminary phase fluid resuscitation in adult patients with dengue.

    PubMed

    Premaratna, R; Ragupathy, A; Miththinda, J K N D; de Silva, H J

    2013-07-01

    Fluid leakage remains the hallmark of dengue hemorrhagic fever (DHF). The applicability of currently recommended predictors of DHF for adults with dengue is questionable as these are based on studies conducted in children. One hundred and two adults with dengue were prospectively followed up to investigate whether home-based or hospital-based early phase fluid resuscitation has an impact on clinical and hematological parameters used for the diagnosis of early or critical phase fluid leakage. In the majority of subjects, third space fluid accumulation (TSFA) was detected on the fifth and sixth days of infection. The quantity and quality of fluids administered played no role in TSFA. A reduction in systolic blood pressure appeared to be more helpful than a reduction in pulse pressure in predicting fluid leakage. TSFA occurred with lower percentage rises in packed cell volume (PCV) than stated in the current recommendations. A rapid reduction in platelets, progressive reduction in white blood cells, percentage rises in Haemoglobin (Hb), and PCV, and rises in aspartate aminotransferase and alanine aminotransferase were observed in patients with TSFA and therefore with the development of severe illness. Clinicians should be aware of the limitations of currently recommended predictors of DHF in adult patients who are receiving fluid resuscitation. Copyright © 2013 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  15. The Gravity of Giraffe Physiology

    NASA Technical Reports Server (NTRS)

    Hargens, Alan R.; Holton, Emily M. (Technical Monitor)

    1997-01-01

    By virtue of its tallness and terrestrial environment, the giraffe is a uniquely sensitive African animal to investigate tissue adaptations to gravitational stress. One decade ago, we studied transcapillary fluid balance and local tissue adaptations to high cardiovascular and musculoskeletal loads in adult and fetal giraffes. Previous studies by Goetz, Pattersson, Van Citters, Warren and their colleagues revealed that arterial pressure near the giraffe heart is about twice that in humans, to provide more normal blood pressure and perfusion to the brain. Another important question is how giraffes avoid pooling of blood and tissue fluid (edema) in dependent tissue of the extremities. As monitored by radiotelemetry, the blood and tissue fluid pressures that govern transcapillary exchange vary greatly with exercise. These pressures, combined with a tight skin layer, move fluid upward against gravity. Other mechanisms that prevent edema include precapillary vasoconstriction and low permeability of capillaries to plasma proteins. Other anatomical adaptations in dependent tissues of giraffes represent developmental adjustments to high and variable gravitational forces. These include vascular wall hypertrophy, thickened capillary basement membrane and other connective tissue adaptations. Our results in giraffe suggest avenues of future gravitational research in other animals including humans.

  16. Photoacoustic microscopy of bilirubin in tissue phantoms

    NASA Astrophysics Data System (ADS)

    Zhou, Yong; Zhang, Chi; Yao, Da-Kang; Wang, Lihong V.

    2012-12-01

    Determining both bilirubin's concentration and its spatial distribution are important in disease diagnosis. Here, for the first time, we applied quantitative multiwavelength photoacoustic microscopy (PAM) to detect bilirubin concentration and distribution simultaneously. By measuring tissue-mimicking phantoms with different bilirubin concentrations, we showed that the root-mean-square error of prediction has reached 0.52 and 0.83 mg/dL for pure bilirubin and for blood-mixed bilirubin detection (with 100% oxygen saturation), respectively. We further demonstrated the capability of the PAM system to image bilirubin distribution both with and without blood. Finally, by underlaying bilirubin phantoms with mouse skins, we showed that bilirubin can be imaged with consistent accuracy down to >400 μm in depth. Our results show that PAM has potential for noninvasive bilirubin monitoring in vivo, as well as for further clinical applications.

  17. Kidney Failure

    MedlinePlus

    Healthy kidneys clean your blood by removing excess fluid, minerals, and wastes. They also make hormones that keep your ... strong and your blood healthy. But if the kidneys are damaged, they don't work properly. Harmful ...

  18. Neisseria meningitidis and Moraxella osloensis: dual infection in blood and peritoneal fluid.

    PubMed

    Tiosejo, L L; Hocko, M; Bartholomew, W R; Amsterdam, D

    1988-12-01

    The clinical course of a malnourished alcoholic in which Neisseria meningitidis was isolated from the blood and Moraxella osloensis from the peritoneal fluid is described. Following bacteriologic diagnosis, the patient was treated and responded to a course of penicillin therapy. To our knowledge, this represents the first case of peritonitis associated with M. osloensis. Clinical reports of the isolation of this organism are rare; its pathogenicity is not clearly established, and the presence of the organism may often be unrecognized.

  19. Validated method for the simultaneous determination of Delta9-THC and Delta9-THC-COOH in oral fluid, urine and whole blood using solid-phase extraction and liquid chromatography-mass spectrometry with electrospray ionization.

    PubMed

    Teixeira, Helena; Verstraete, Alain; Proença, Paula; Corte-Real, Francisco; Monsanto, Paula; Vieira, Duarte Nuno

    2007-08-06

    A fully validated, sensitive and specific method for the extraction and quantification of Delta(9)-tetrahydrocannabinol (THC) and 11-nor-9-carboxy-Delta(9)-THC (THC-COOH) and for the detection of 11-hydroxy-Delta(9)-THC (11-OH THC) in oral fluid, urine and whole blood is presented. Solid-phase extraction and liquid chromatography-mass spectrometry (LC-MS) technique were used, with electrospray ionization. Three ions were monitored for THC and THC-COOH and two for 11-OH THC. The compounds were quantified by selected ion recording of m/z 315.31, 329.18 and 343.16 for THC, 11-OH THC and THC-COOH, respectively, and m/z 318.27 and 346.26 for the deuterated internal standards, THC-d(3) and THC-COOH-d(3), respectively. The method proved to be precise for THC and THC-COOH both in terms of intra-day and inter-day analysis, with intra-day coefficients of variation (CV) less than 6.3, 6.6 and 6.5% for THC in saliva, urine and blood, respectively, and 6.8 and 7.7% for THC-COOH in urine and blood, respectively. Day-to-day CVs were less than 3.5, 4.9 and 11.3% for THC in saliva, urine and blood, respectively, and 6.2 and 6.4% for THC-COOH in urine and blood, respectively. Limits of detection (LOD) were 2 ng/mL for THC in oral fluid and 0.5 ng/mL for THC and THC-COOH and 20 ng/mL for 11-OH THC, in urine and blood. Calibration curves showed a linear relationship for THC and THC-COOH in all samples (r(2)>0.999) within the range investigated. The procedure presented here has high specificity, selectivity and sensitivity. It can be regarded as an alternative method to GC-MS for the confirmation of positive immunoassay test results, and can be used as a suitable analytical tool for the quantification of THC and THC-COOH in oral fluid, urine and/or blood samples.

  20. A rabbit model of fatal hypothyroidism mimicking "myxedema coma" established by microscopic total thyroidectomy.

    PubMed

    Ono, Yosuke; Fujita, Masanori; Ono, Sachiko; Ogata, Sho; Tachibana, Shoichi; Tanaka, Yuji

    2016-06-30

    Myxedema coma (MC) is a life-threatening endocrine crisis caused by severe hypothyroidism. However, validated diagnostic criteria and treatment guidelines for MC have not been established owing to its rarity. Therefore, a valid animal model is required to investigate the pathologic and therapeutic aspects of MC. The aim of the present study was to establish an animal model of MC induced by total thyroidectomy. We utilized 14 male New Zealand White rabbits anesthetized via intramuscular ketamine and xylazine administration. A total of 7 rabbits were completely thyroidectomized under a surgical microscope (thyroidectomized group) and the remainder underwent sham operations (control group). The animals in both groups were monitored without thyroid hormone replacement for 15 weeks. Pulse rate, blood pressure, body temperature, and electrocardiograms (ECG) were recorded and blood samples were taken from the jugular vein immediately prior to the thyroidectomy and 2 and 4 weeks after surgery. The thyroidectomized rabbits showed a marked reduction of serum thyroxine levels at 4 weeks after the surgical procedure vs. controls (0.50±0.10 vs. 3.32±0.68 μg/dL, p<0.001). Additionally, thyroidectomized rabbits exhibited several signs of hypothyroidism such as hypothermia, systolic hypotension, bradycardia, and low voltage on ECGs, compared with controls. Of the 7 rabbits with severe hypothyroidism, 6 died from 4 to 14 weeks after the thyroidectomy possibly owing to heart failure, because histopathologic examinations revealed a myxedema heart. In summary, we have established a rabbit model of fatal hypothyroidism mimicking MC, which may facilitate pathophysiological and molecular investigations of MC and evaluations of new therapeutic interventions.

  1. Mercury Toxicity Following Unauthorized Siddha Medicine Intake – A Mimicker of Acquired Neuromyotonia - Report of 32 Cases

    PubMed Central

    Gnanashanmugam, G.; Balakrishnan, R.; Somasundaram, S. P.; Parimalam, N.; Rajmohan, P.; Pranesh, M. B.

    2018-01-01

    Context: Mercury is used extensively in the preparation of Siddha medicines, after purification. In this study, we present 32 patients of mercury toxicity following unauthorized Siddha medicine intake who mimicked neuromyotonia clinically. We analyzed the clinical features of these patients, the role of autoimmunity in etiopathology, and compared it with acquired neuromyotonia. Subjects and Methods: This is a retrospective study to analyze inpatients in a tertiary care center, admitted with mercury toxicity following Siddha medicine intake from August 2012 to October 2016. We analyzed the clinical features, laboratory data including mercury, arsenic and lead levels in blood, and serum voltage-gated potassium channels (VGKC)-CASPR2 Ab in selected patients. Results: Thirty-two patients who had high blood mercury levels following Siddha medicine intake were included in the study. All patients (100%) had severe intractable neuropathic pain predominantly involving lower limbs. Twenty-six (81.25%) patients had fasciculations and myokymia. Fifteen patients (46.86%) had autonomic dysfunction (postural hypotension and resting tachycardia). Nine (28.12%) patients had encephalopathic features such as dullness, apathy, drowsiness, or delirium. Anti-VGKC Ab was positive in 12 patients with myokymia. All the patients in the study consumed Siddha medicines obtained from unauthorized dealers. Conclusions: Mercury toxicity following Siddha medicine intake closely mimics acquired neuromyotonia; severe intolerable neuropathic pain is the hallmark feature; Positive VGKC-CASPR2 antibody in some patients must be due to triggered autoimmunity secondary to mercury toxicity due to Siddha medicine intake. The government should establish licensing system to prevent distribution of unauthorized Siddha medicines. PMID:29720798

  2. Mercury Toxicity Following Unauthorized Siddha Medicine Intake - A Mimicker of Acquired Neuromyotonia - Report of 32 Cases.

    PubMed

    Gnanashanmugam, G; Balakrishnan, R; Somasundaram, S P; Parimalam, N; Rajmohan, P; Pranesh, M B

    2018-01-01

    Mercury is used extensively in the preparation of Siddha medicines, after purification. In this study, we present 32 patients of mercury toxicity following unauthorized Siddha medicine intake who mimicked neuromyotonia clinically. We analyzed the clinical features of these patients, the role of autoimmunity in etiopathology, and compared it with acquired neuromyotonia. This is a retrospective study to analyze inpatients in a tertiary care center, admitted with mercury toxicity following Siddha medicine intake from August 2012 to October 2016. We analyzed the clinical features, laboratory data including mercury, arsenic and lead levels in blood, and serum voltage-gated potassium channels (VGKC)-CASPR2 Ab in selected patients. Thirty-two patients who had high blood mercury levels following Siddha medicine intake were included in the study. All patients (100%) had severe intractable neuropathic pain predominantly involving lower limbs. Twenty-six (81.25%) patients had fasciculations and myokymia. Fifteen patients (46.86%) had autonomic dysfunction (postural hypotension and resting tachycardia). Nine (28.12%) patients had encephalopathic features such as dullness, apathy, drowsiness, or delirium. Anti-VGKC Ab was positive in 12 patients with myokymia. All the patients in the study consumed Siddha medicines obtained from unauthorized dealers. Mercury toxicity following Siddha medicine intake closely mimics acquired neuromyotonia; severe intolerable neuropathic pain is the hallmark feature; Positive VGKC-CASPR2 antibody in some patients must be due to triggered autoimmunity secondary to mercury toxicity due to Siddha medicine intake. The government should establish licensing system to prevent distribution of unauthorized Siddha medicines.

  3. Etiology of parapneumonic effusion and pleural empyema in children. The role of conventional and molecular microbiological tests.

    PubMed

    Krenke, Katarzyna; Sadowy, Ewa; Podsiadły, Edyta; Hryniewicz, Waleria; Demkow, Urszula; Kulus, Marek

    2016-07-01

    An increasing incidence of parapneumonic effusion and pleural empyema (PPE/PE) has been reported in recent studies. As only few data on etiology of PPE/PE in Central Europe have been reported, we undertook a study on the etiology of PPE/PE in children, using both standard culture and molecular techniques. This prospective study was conducted between June 2011 and December 2013. Consecutive children with PPE/PE complicating community acquired pneumonia, who required diagnostic/therapeutic thoracentesis were included. Blood and pleural fluid samples for microbiological cultures were collected. Molecular methods were applied to identify Streptococcus pneumonia, Haemophilus influenzae, Staphylococcus aureus, Streptococcus pyogenes, Mycoplasma pneumoniae, Chlamydophila pneumoniae, and respiratory viruses in pleural fluid. The study group included 64 children, median age 4 (1-15). Seven of 64 (10.9%) blood cultures and 11 of 64 (17.2%) pleural fluid cultures revealed bacterial growth. The most common bacteria detected was S. pneumoniae (13 blood and pleural fluid samples from 11/64 (17.2%) children). DNA sequences of typical bacteria were found in 29/64 (45.3%) pleural fluid samples. S. pneumoniae was identified in 90% of these samples. The most common serotypes were: serotype 6B in 9/26 (36.6%), 19A in 6/26 (23%), serotype 3 in 3/26 (11.5%), 6A and 23F (both in 2/26 i.e. 7.7%) patients. Molecular methods identified atypical bacteria in 8/58 (13.8%) and respiratory viruses in 12/58 (20.7%) pleural fluid samples. S. pneumoniae, in particular serotype 6B and 19A, is the most common etiologic agent of PPE/PE in Polish children. The use of PCR significantly improves pathogen identification in pleural fluid. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Renal excretion of water in men under hypokinesia and physical exercise with fluid and salt supplementation

    NASA Astrophysics Data System (ADS)

    Zorbas, Yan G.; Federenko, Youri F.; Togawa, Mitsui N.

    It has been suggested that under hypokinesia (reduced number of steps/day) and intensive physical exercise, the intensification of fluid excretion in men is apparently caused as a result of the inability of the body to retain optimum amounts of water. Thus, to evaluate this hypothesis, studies were performed with the use of fluid and sodium chloride (NaCl) supplements on 12 highly trained physically healthy male volunteers aged 19-24 years under 364 days of hypokinesis (HK) and a set of intensive physical exercises (PE). They were divided into two groups with 6 volunteers per group. The first group of subjects were submitted to HK and took daily fluid and salt supplements in very small doses and the second group of volunteers were subjected to intensive PE and fluid-salt supplements. For the simulation of the hypokinetic effect, both groups of subjects were kept under an average of 4000 steps/day. During the prehypokinetic period of 60 days and under the hypokinetic period of 364 days water consumed and eliminated in urine by the men, water content in blood, plasma volume, rate of glomerular filtration, renal blood flow, osmotic concentration of urine and blood were measured. Under HK, the rate of renal excretion of water increased considerably in both groups. The additional fluid and salt intake failed to normalize water balance adequately under HK and PE. It was concluded that negative water balance evidently resulted not from shortage of water in the diet but from the inability of the body to retain optimum amounts of fluid under HK and a set of intensive PEs.

  5. Pelvic Hydatidosis Mimicking a Malignant Multicystic Ovarian Tumor

    PubMed Central

    Mushtaq, Deeba; Verma, Neetu; Mahajan, N. C.

    2010-01-01

    Echinococcosis is a multisystem disease and has propensity to involve any organ, an unusual anatomical site, and can mimic any disease process. Primary peritoneal echinococcosis is known to occur secondary to hepatic involvement but occasional cases of primary peritoneal hydatid disease including pelvic involvement have also been reported. We report here 1 such case of primary pelvic hydatidosis mimicking a malignant multicystic ovarian tumor where there was no evidence of involvement of the liver or spleen. Our patient, a 27-year-old female, was detected to have a large right cystic adnexal mass on per vaginal examination which was confirmed by ultrasonography. Her biochemical parameters were normal and CA-125 levels, though mildly raised, were below the cut off point. She underwent surgery and on exploratory laparotomy, another cystic mass was found attached to the mesentery of the small gut. The resected cysts were processed histopathologically. On cut sections both large cysts revealed numerous daughter cysts. Microscopic examination of fluid from the cysts revealed free scolices with hooklets and the cyst wall had a typical laminated membrane with inner germinal layer containing degenerated protoplasmic mass. The diagnosis of pelvic hydatid disease was confirmed and patient was managed accordingly. Hydatid disease must be considered while making the differential diagnosis of pelvic cystic masses, especially in endemic areas. PMID:20877508

  6. Cordylobia rodhaini infestation of the breast: Report of a case mimicking a breast abscess.

    PubMed

    Grassi, Veronica; Butterworth, James William; Latiffi, Layloma

    2016-01-01

    Myiasis, parasitic infestation of the body by fly larvae, caused by the Cordylobia rodhaini is very rare with only fourteen cases published since 1970. We present a rare case of myiasis mimicking a breast abscess. A 17-year-old female presented with a nodular ulcerative lesion in her left breast 14days following a trip to Ghana. She had been initially unsuccessfully treated with the antibiotic flucloxacillin following a misdiagnosis of a breast abscess. Following application of Vaseline to the breast wound, covering the wound for 2h and gentle manipulation the larvae was removed successfully and the patient made a good recovery. Presenting as an inflammatory papule with central opening oozing serosanguinous fluid myiasis secondary to C. rodhaini can easily be mistaken for a breast abscess, often avoiding detection by unsuspecting surgeons on initial assessment. In turn ineffective antibiotic treatment is often prescribed leading to further disease progression and associated morbidity. Myiasis secondary to C. rodhaini is a rare but important differential surgeons should consider in women presenting with an inflammatory breast lesion with a recent history of foreign travel to ensure timely diagnosis and treatment. Ultrasound imaging can be useful in confirming diagnosis and avoiding treatment delays. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  7. Biomimetic engineering of a generic cell-on-membrane architecture by microfluidic engraving for on-chip bioassays.

    PubMed

    Lee, Sang-Wook; Noh, Ji-Yoon; Park, Seung Chul; Chung, Jin-Ho; Lee, Byoungho; Lee, Sin-Doo

    2012-05-22

    We develop a biomimetic cell-on-membrane architecture in close-volume format which allows the interfacial biocompatibility and the reagent delivery capability for on-chip bioassays. The key concept lies in the microfluidic engraving of lipid membranes together with biological cells on a supported substrate with topographic patterns. The simultaneous engraving process of a different class of fluids is promoted by the front propagation of an air-water interface inside a flow-cell. This highly parallel, microfluidic cell-on-membrane approach opens a door to the natural biocompatibility in mimicking cellular stimuli-response behavior essential for diverse on-chip bioassays that can be precisely controlled in the spatial and temporal manner.

  8. Otoconial formation in the fetal rat

    NASA Technical Reports Server (NTRS)

    Salamat, M. S.; Ross, M. D.; Peacor, D. R.

    1980-01-01

    Otoconial formation in the fetal rat is examined by scanning and transmission electron microscopy, and by X-ray elemental analysis. The primitive otoconia appear highly organic, but are trigonal in cross section, indicating that they already possess a three-fold axis of symmetry and a complement of calcite. These otoconia develop into spindle-shaped and, subsequently, dumbbell-shaped units. Transmission electron microscopy of dumbbell-shaped otoconia not exposed to fluids during embedment showed that calcite deposits mimicked the arrangement of the organic material. X-ray elemental analysis demonstrated that calcium was present in lower quantities in the central core than peripherally. It is concluded that organic material is essential to otoconial seeding and directs otoconial growth.

  9. A magnetic fluid seal for rotary blood pumps: effects of seal structure on long-term performance in liquid.

    PubMed

    Mitamura, Yoshinori; Takahashi, Sayaka; Amari, Shuichi; Okamoto, Eiji; Murabayashi, Shun; Nishimura, Ikuya

    2011-03-01

    A magnetic fluid (MF) seal enables mechanical contact-free rotation of the shaft and hence has excellent durability. The performance of an MF seal, however, has been reported to decrease in liquids. We developed an MF seal that has a "shield" mechanism, and a new MF with a higher magnetization of 47.9 kA/m. The sealing performance of the MF seal installed in a rotary blood pump was studied. Three types of MF seals were used. Seal A was a conventional seal without a shield. Seal B had the same structure as that of Seal A, but the seal was installed at 1 mm below liquid level. Seal C was a seal with a shield and the MF was set at 1 mm below liquid level. Seal A failed after 6 and 11 days. Seal B showed better results (20 and 73 days). Seal C showed long-term durability (217 and 275 days). The reason for different results in different seal structures was considered to be different flow conditions near the magnetic fluid. Fluid dynamics near the MF in the pump were analyzed using computational fluid dynamics (CFD) software. We have developed an MF seal with a shield that works in liquid for >275 days. The MF seal is promising as a shaft seal for rotary blood pumps.

  10. Clinical utility of capillary polymerase chain reaction for diagnosis of Cytomegalovirus pneumonia.

    PubMed

    Honda, J; Yonemitsu, J; Kitajima, H; Yosida, N; Fumirori, T; Oizumi, K

    2001-01-01

    The purpose of this retrospective study was to assess the diagnostic efficacy of CMV DNA detection by capillary PCR in patients with interstitial pneumonia. Of 882 samples taken from 363 patients, 317 were obtained from sputum, 94 from BAL fluid, 291 from blood and 180 from urine. PCR for CMV was positive in 58 samples (6.6%), with positive detection for 6.9% of sputum, 10.6% of BAL fluid, 4.1% of blood and 7.8% of urine samples. CMV pneumonia was diagnosed retrospectively in 34 (9.4%) of the 363 patients by demonstration of CMV antigen-positive cytomegalic inclusion bodies in lung tissue sections. The positive and negative predictive values were 100% (10/10) and 98.8% (83/84) for the BAL fluid samples and 95.5% (21/22) and 99.7% (294/295) for the sputum samples, respectively. Clinical sensitivity and specificity were 90.9% (10/11) and 100% (83/83) for the BAL fluid samples and 95.5% (21/22) and 99.7% (294/295) for the sputum samples, respectively. However, the blood and urine samples showed poor clinical sensitivity and low positive predictive values. We suggest that the use of capillary PCR for BAL fluid and sputum samples is very useful for diagnosing CMV pneumonia in patients with interstitial pneumonia in whom CMV pneumonia is suspected.

  11. Insulin transport into the brain.

    PubMed

    Gray, Sarah M; Barrett, Eugene J

    2018-05-30

    While there is a growing consensus that insulin has diverse and important regulatory actions on the brain, seemingly important aspects of brain insulin physiology are poorly understood. Examples include: what is the insulin concentration within brain interstitial fluid under normal physiologic conditions; whether insulin is made in the brain and acts locally; does insulin from the circulation cross the blood-brain barrier or the blood-CSF barrier in a fashion that facilitates its signaling in brain; is insulin degraded within the brain; do privileged areas with a "leaky" blood-brain barrier serve as signaling nodes for transmitting peripheral insulin signaling; does insulin action in the brain include regulation of amyloid peptides; whether insulin resistance is a cause or consequence of processes involved in cognitive decline. Heretofore, nearly all studies examining brain insulin physiology have employed techniques and methodologies that do not appreciate the complex fluid compartmentation and flow throughout the brain. This review attempts to provide a status report on historical and recent work that begins to address some of these issues. It is undertaken in an effort to suggest a framework for studies going forward. Such studies are inevitably influenced by recent physiologic and genetic studies of insulin accessing and acting in brain, discoveries relating to brain fluid dynamics and the interplay of cerebrospinal fluid, brain interstitial fluid, and brain lymphatics, and advances in clinical neuroimaging that underscore the dynamic role of neurovascular coupling.

  12. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor.

    PubMed

    Stens, Jurre; Oeben, Jeroen; Van Dusseldorp, Ab A; Boer, Christa

    2016-10-01

    Nexfin beat-to-beat arterial blood pressure monitoring enables continuous assessment of hemodynamic indices like cardiac index (CI), pulse pressure variation (PPV) and stroke volume variation (SVV) in the perioperative setting. In this study we investigated whether Nexfin adequately reflects alterations in these hemodynamic parameters during a provoked fluid shift in anesthetized and mechanically ventilated patients. The study included 54 patients undergoing non-thoracic surgery with positive pressure mechanical ventilation. The provoked fluid shift comprised 15° Trendelenburg positioning, and fluid responsiveness was defined as a concomitant increase in stroke volume (SV) >10 %. Nexfin blood pressure measurements were performed during supine steady state, Trendelenburg and supine repositioning. Hemodynamic parameters included arterial blood pressure (MAP), CI, PPV and SVV. Trendelenburg positioning did not affect MAP or CI, but induced a decrease in PPV and SVV by 3.3 ± 2.8 and 3.4 ± 2.7 %, respectively. PPV and SVV returned back to baseline values after repositioning of the patient to baseline. Bland-Altman analysis of SVV and PPV showed a bias of -0.3 ± 3.0 % with limits of agreement ranging from -5.6 to 6.2 %. The SVV was more superior in predicting fluid responsiveness (AUC 0.728) than the PVV (AUC 0.636), respectively. The median bias between PPV and SVV was different for patients younger [-1.5 % (-3 to 0)] or older [+2 % (0-4.75)] than 55 years (P < 0.001), while there were no gender differences in the bias between PPV and SVV. The Nexfin monitor adequately reflects alterations in PPV and SVV during a provoked fluid shift, but the level of agreement between PPV and SVV was low. The SVV tended to be superior over PPV or Eadyn in predicting fluid responsiveness in our population.

  13. C5a and C5aR are elevated in joints of rheumatoid and psoriatic arthritis patients, and C5aR blockade attenuates leukocyte migration to synovial fluid.

    PubMed

    Hornum, Lars; Hansen, Anker Jon; Tornehave, Ditte; Fjording, Marianne Scheel; Colmenero, Paula; Wätjen, Inger Falbe; Søe Nielsen, Niels Henrik; Bliddal, Henning; Bartels, Else Marie

    2017-01-01

    Complement activation correlates to rheumatoid arthritis disease activity, and increased amounts of the complement split product C5a is observed in synovial fluids from rheumatoid arthritis patients. Blockade of C5a or its receptor (C5aR) is efficacious in several arthritis models. The aim of this study was to investigate the role of C5a and C5aR in human rheumatoid arthritis and psoriatic arthritis-both with respect to expression and function. Synovial fluid, blood and synovial samples were obtained from rheumatoid arthritis, psoriatic arthritis and osteoarthritis patients as a less inflammatory arthritis type, and blood from healthy subjects. Cells infiltrating synovial tissue were analysed by immunohistochemistry and flow cytometry. SF and blood were analysed for biomarkers by flow cytometry or ELISA. The effect of a blocking anti-human C5aR mAb on leukocyte migration was determined using a Boyden chamber. Appropriate statistical tests were applied for comparisons. C5aR+ cells were detected in most rheumatoid arthritis, in all psoriatic arthritis, but not in non-inflammatory control synovia. C5aR+ cells were primarily neutrophils and macrophages. C5aR+ macrophages were mainly found in lymphoid aggregates in close contact with T cells. C5a levels were increased in both rheumatoid arthritis and psoriatic arthritis synovial fluid compared to osteoarthritis, and in blood from rheumatoid arthritis compared to healthy subjects. Neutrophil and monocyte migration to rheumatoid arthritis synovial fluid was significantly inhibited by anti-C5aR. The data support that the C5a-C5aR axis may be driving the infiltration of inflammatory cells into the synovial fluid and synovium in both rheumatoid and psoriatic arthritis, and suggest that C5a or C5aR may be a promising treatment target in both diseases.

  14. Development of Highly Sensitive and Specific mRNA Multiplex System (XCYR1) for Forensic Human Body Fluids and Tissues Identification

    PubMed Central

    Xu, Yan; Xie, Jianhui; Cao, Yu; Zhou, Huaigu; Ping, Yuan; Chen, Liankang; Gu, Lihua; Hu, Wei; Bi, Gang; Ge, Jianye; Chen, Xin; Zhao, Ziqin

    2014-01-01

    The identification of human body fluids or tissues through mRNA-based profiling is very useful for forensic investigations. Previous studies have shown mRNA biomarkers are effective to identify the origin of biological samples. In this study, we selected 16 tissue specific biomarkers to evaluate their specificities and sensitivities for human body fluids and tissues identification, including porphobilinogen deaminase (PBGD), hemoglobin beta (HBB) and Glycophorin A (GLY) for circulatory blood, protamine 2 (PRM2) and transglutaminase 4 (TGM4) for semen, mucin 4 (MUC4) and human beta defensin 1(HBD1) for vaginal secretion, matrix metalloproteinases 7 and 11 (MMP7 and MMP11) for menstrual blood, keratin 4(KRT4) for oral mucosa, loricrin (LOR) and cystatin 6 (CST6) for skin, histatin 3(HTN3) for saliva, statherin (STATH) for nasal secretion, dermcidin (DCD) for sweat and uromodulin (UMOD) for urine. The above mentioned ten common forensic body fluids or tissues were used in the evaluation. Based on the evaluation, a reverse transcription (RT) PCR multiplex assay, XCYR1, which includes 12 biomarkers (i.e., HBB, GLY, HTN3, PRM2, KRT4, MMP11, MUC4, DCD, UMOD, MMP7, TGM4, and STATH) and 2 housekeeping genes [i.e., glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and 18SrRNA], was developed. This assay was further validated with real casework samples and mock samples (with both single source and mixture) and it was approved that XCYR1 is effective to identify common body fluids or tissues (i.e., circulatory blood, saliva, semen, vaginal secretion, menstrual blood, oral mucosa, nasal secretion, sweat and urine) in forensic casework samples. PMID:24991806

  15. Hemodynamic and permeability characteristics of acute experimental necrotizing enterocolitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, M.J.; Adams, J.; Gu, X.A.

    1990-10-01

    We examined the local hemodynamic response of intestinal loops during acute necrotizing enterocolitis (NEC) in anesthetized rabbits. NEC was induced in ileal loops by transmural injection of a solution containing casein (10 mg/ml) and calcium gluconate (50 mg/ml) acidified to pH 4.0 with propionic or acetic acid. Control loops received casein only (pH 5.0). Mucosal damage was quantified by the blood-to-lumen movement of (51Cr)EDTA, fluid shifts into the lumen, and histology. Mean arterial pressure and loop blood flow were steady over the 3-hr period, loop fluid volume decreased, and there was no evidence of necrosis or epithelial damage. In loopsmore » receiving acidified casein and calcium gluconate, there was an immediate dramatic increase in loop blood flow that returned to baseline by 50 min. In addition, loop fluid volume was dramatically increased, necrosis was noted in the form of blunting and loss of villi, and sevenfold increase in (51Cr)EDTA permeability was evident. Administration of CV 1808 (30 mg/kg/hr), a selective adenosine2 agonist, which maintained and elevated loop blood flow throughout the 3 hr protocol, failed to alter the changes in loop fluid volume or prevent necrosis. Histamine levels in loop fluid levels were significantly elevated 20-30 min after NEC induction when compared to saline controls, indicating an early activation of mucosal defenses with this luminal insult. Thus, this model of NEC is characterized by a transient, acute hyperemia, increased intestinal permeability, and histamine release. As mucosal damage was independent of ischemia and could not be prevented by vasodilatory therapy, this model supports the clinical findings that NEC is correlated with luminal factors related to feeding and independent of cardiovascular stress.« less

  16. Development of highly sensitive and specific mRNA multiplex system (XCYR1) for forensic human body fluids and tissues identification.

    PubMed

    Xu, Yan; Xie, Jianhui; Cao, Yu; Zhou, Huaigu; Ping, Yuan; Chen, Liankang; Gu, Lihua; Hu, Wei; Bi, Gang; Ge, Jianye; Chen, Xin; Zhao, Ziqin

    2014-01-01

    The identification of human body fluids or tissues through mRNA-based profiling is very useful for forensic investigations. Previous studies have shown mRNA biomarkers are effective to identify the origin of biological samples. In this study, we selected 16 tissue specific biomarkers to evaluate their specificities and sensitivities for human body fluids and tissues identification, including porphobilinogen deaminase (PBGD), hemoglobin beta (HBB) and Glycophorin A (GLY) for circulatory blood, protamine 2 (PRM2) and transglutaminase 4 (TGM4) for semen, mucin 4 (MUC4) and human beta defensin 1(HBD1) for vaginal secretion, matrix metalloproteinases 7 and 11 (MMP7 and MMP11) for menstrual blood, keratin 4(KRT4) for oral mucosa, loricrin (LOR) and cystatin 6 (CST6) for skin, histatin 3(HTN3) for saliva, statherin (STATH) for nasal secretion, dermcidin (DCD) for sweat and uromodulin (UMOD) for urine. The above mentioned ten common forensic body fluids or tissues were used in the evaluation. Based on the evaluation, a reverse transcription (RT) PCR multiplex assay, XCYR1, which includes 12 biomarkers (i.e., HBB, GLY, HTN3, PRM2, KRT4, MMP11, MUC4, DCD, UMOD, MMP7, TGM4, and STATH) and 2 housekeeping genes [i.e., glyceraldehyde-3-phosphate dehydrogenase (GAPDH) and 18SrRNA], was developed. This assay was further validated with real casework samples and mock samples (with both single source and mixture) and it was approved that XCYR1 is effective to identify common body fluids or tissues (i.e., circulatory blood, saliva, semen, vaginal secretion, menstrual blood, oral mucosa, nasal secretion, sweat and urine) in forensic casework samples.

  17. Amniotic fluid gamma-glutamyl transpeptidase activity during the second trimester.

    PubMed

    Legge, M; Potter, H C

    1986-03-12

    Gamma glutamyl transpeptidase (GGTP) activity was determined in second trimester amniotic fluid taken from normal fetuses and those with fetal abnormalities. GGTP activity decreased with advancing gestation. Increasing meconium contamination correlated with an increase in GGTP activity as did increasing fetal blood contamination. Maternal blood did not affect GGTP activity. Anencephaly did not significantly alter the GGTP activity, however, fetuses with spina bifida had significantly lower activity. Klinefelters and Turners syndromes both had GGTP activity close to the 50th percentile, and two trisomy 21 fetuses had GGTP activity below the 40th percentile. Two trisomy 18 fetuses and two translocation Downs syndromes (46 XY, t (14;21) had GGTP activities considerably lower than the 20th percentile as did a fetus with gastroschisis. Second trimester amniotic fluid GGTP activity may provide an easy preliminary test to screen amniotic fluids for the possibility of certain fetal chromosome abnormalities.

  18. Lymphatic System Flows

    NASA Astrophysics Data System (ADS)

    Moore, James E., Jr.; Bertram, Christopher D.

    2018-01-01

    The supply of oxygen and nutrients to tissues is performed by the blood system and involves a net leakage of fluid outward at the capillary level. One of the principal functions of the lymphatic system is to gather this fluid and return it to the blood system to maintain overall fluid balance. Fluid in the interstitial spaces is often at subatmospheric pressure, and the return points into the venous system are at pressures of approximately 20 cmH2O. This adverse pressure difference is overcome by the active pumping of collecting lymphatic vessels, which feature closely spaced one-way valves and contractile muscle cells in their walls. Passive vessel squeezing causes further pumping. The dynamics of lymphatic pumping have been investigated experimentally and mathematically, revealing complex behaviors that indicate that the system performance is robust against minor perturbations in pressure and flow. More serious disruptions can lead to incurable swelling of tissues called lymphedema.

  19. [Levels of unified metabolites and thyroid hormones in blood and oral fluid of children with minimal brain dysfunction].

    PubMed

    Gil'miiarova, F N; Pervova, Iu V; Radomskaia, V M; Gergel', N I; Tarasova, S V

    2004-01-01

    Minimal brain dysfunctions in children with various perinatal complications are accompanied by metabolic imbalance manifested by decreased total protein content, the tendency to reduced triglycerides, increased cholesterol concentrations in the oral fluid, the trend to hypoproteinaemia, hypoglycaemia, hypotriglyceridaemia. The most significant changes in the redox systems alpha-ketoglutarate-glutamate, oxaloacetate-malate, pyruvate-lactate, dioxyacetone phosphate-alpha-glycerophosphate in biological fluids were revealed in cases of antenatal alcoholisation. A certain correlation was found between anemia in pregnant women and hypothyroidal background in children. In addition, a high level of free and total thyroxine, that of total triiodthyronine were found in the oral fluid. Hypophysis--thyroid dysregulation in children with minimal brain dysfunction associated with gestosis in their mothers during pregnancy, was manifested by decreased content of total and free T4 and T3 in blood serum and increased level of the thyroid-stimulating hormone.

  20. [Diagnostic performance of T-SPOT.TB on peripheral blood in combination with adenosine deaminase on pleural fluid for the diagnosis of tuberculous pleurisy within different age group].

    PubMed

    Xu, H Y; Zhang, D Q; Ye, J R; Su, S S; Xie, Y P; Chen, C S; Li, Y P

    2017-06-27

    Objective: To evaluate the performance of T cell enzyme-linked immuno-spot assay (T-SPOT) on peripheral blood in combination with adenosine deaminase (ADA) on pleural fluid for diagnosis of tuberculous (TB) pleurisy within different age groups. Methods: The data of patients with pleural effusion from the Department of Pulmonary and Critical Care Medicine of the First Affiliated Hospital of Wenzhou Medical University from April 2012 to November 2016 were retrospectively analyzed, and the diagnoses of these patients were histopathologically confirmed through medical thoracoscopy. The cases who had confirmed diagnosis, in the same time, received peripheral blood T-SPOT.TB were enrolled. The performance of peripheral blood T-SPOT.TB in combination with pleural fluid ADA on diagnosing TB pleurisy in the younger patients (16-59 years old) and elderly patients (≥60 years old) were analyzed respectively. The sensitivity, specificity and the receiver operating characteristic (ROC) curve were adopted for statistical analysis. Results: A total of 448 cases were finally enrolled, 341(76.1%) confirmed with TB pleurisy, 224 males, 117 females, (47±19) years old; and 107 (23.9%) classified as non-TB pleurisy, 65 males, 42 females, (61±14) years old. There were 285 cases who were classified as younger group, and the other 163 cases were classified as elderly group. The sensitivity and specificity of peripheral blood T-SPOT.TB were 85.4% (204/239) and 71.7% (33/46) in the younger patients, 76.5% (78/102) and 59.0% (36/61) respectively in the elderly patients. The sensitivity of peripheral blood T-SPOT.TB in the younger patients was significantly higher than that in the elderly patients ( P =0.047). The sensitivity and specificity were 99.2% and 95.7% in combination with peripheral blood T-SPOT.TB and pleural fluid ADA respectively in the younger patients. The area under ROC curve (AUC) of T-SPOT.TB in the younger patients was 0.833, AUC of T-SPOT.TB combined with ADA was 0.911. The combination test of 2 tests had the sensitivity of 96.1% and the specificity of 90.2% respectively in the elderly patients. The AUC of T-SPOT.TB in the elderly patients was 0.747, AUC of T-SPOT.TB combined with ADA was 0.911. Conclusion: Peripheral blood T-SPOT.TB combined with pleural fluid ADA can improve the diagnostic performance for TB pleurisy with different ages, especially for elderly patients who can't tolerate pleural biopsy.

  1. Glucose predictability, blood capillary permeability, and glucose utilization rate in subcutaneous, skeletal muscle, and visceral fat tissues.

    PubMed

    Koutny, Tomas

    2013-11-01

    This study suggests an approach for the comparison and evaluation of particular compartments with modest experimental setup costs. A glucose level prediction model was used to evaluate the compartment's glucose transport rate across the blood capillary membrane and the glucose utilization rate by the cells. The glucose levels of the blood, subcutaneous tissue, skeletal muscle tissue, and visceral fat were obtained in experiments conducted on hereditary hypertriglyceridemic rats. After the blood glucose level had undergone a rapid change, the experimenter attempted to reach a steady blood glucose level by manually correcting the glucose infusion rate and maintaining a constant insulin infusion rate. The interstitial fluid glucose levels of subcutaneous tissue, skeletal muscle tissue, and visceral fat were evaluated to determine the reaction delay compared with the change in the blood glucose level, the interstitial fluid glucose level predictability, the blood capillary permeability, the effect of the concentration gradient, and the glucose utilization rate. Based on these data, the glucose transport rate across the capillary membrane and the utilization rate in a particular tissue were determined. The rates obtained were successfully verified against positron emission tomography experiments. The subcutaneous tissue exhibits the lowest and the most predictable glucose utilization rate, whereas the skeletal muscle tissue has the greatest glucose utilization rate. In contrast, the visceral fat is the least predictable and has the shortest reaction delay compared with the change in the blood glucose level. The reaction delays obtained for the subcutaneous tissue and skeletal muscle tissue were found to be approximately equal using a metric based on the time required to reach half of the increase in the interstitial fluid glucose level. © 2013 Published by Elsevier Ltd.

  2. Distributed modeling of diffusive solute transport in peritoneal dialysis.

    PubMed

    Waniewski, Jacek

    2002-01-01

    The diffusive transport between blood and an ex-tissue medium (dialysis fluid) is evaluated using a mathematical model that takes into account the (quasicontinuous) distribution of capillaries within the tissue at various distances from the tissue surface, and includes diffusive-convective transport through the capillary wall and lymphatic absorption from the tissue. General formulas for solute penetration depth, lambda, and for the diffusive mass transport coefficient for the transport between blood and dialysis fluid, K(BD), are provided in terms of local transport coefficients for capillary wall, tissue, and lymphatic absorption. For pure diffusive transport between blood and dialysis fluid and thick tissue layers (i.e., if the solute penetration depth is much lower than the tissue thickness) these formulas yield previously known expressions. It is shown that apparent tissue layers, with widths lambdaTBL and lambdaT, respectively, may be defined according to the values of local transport parameters in such a way that K(BD) is equal to the solute clearance K(TBL) from the tissue by blood and lymph for a layer with width lambdaTBL or to the solute clearance K(T) from blood to dialysate by diffusion through the tissue layer with width lambdaT. For tissue layers with width much higher than the penetration depth: lambdaT approximately = lambdaTBL approximately = lambda. These characteristic width lengths depend on the transport parameters (and thus on the size) of solutes. Effective blood flow, which may be related to the exchange of the solute between blood and dialysate, is defined using an analogy to the extraction/absorption coefficients for blood-tissue exchange. Various approximations for the distributed model formula for diffusive mass transport coefficient (K(BD)) are possible. The appropriate range for their application is obtained from the general formula.

  3. Blood Warming and Hemolysis: A Systematic Review With Meta-Analysis.

    PubMed

    Poder, Thomas G; Nonkani, Wendyam G; Tsakeu Leponkouo, Élyonore

    2015-07-01

    The use of fluid warmers during blood transfusion is recommended to avoid inducing hypothermia and its harmful effects. Fluid warmers offered by manufacturers can reach temperatures of 43°C. However, the recommendations of national regulatory organizations do not clearly indicate the maximum heating temperature in relation to the risk of hemolysis. To fill this gap, we conducted a systematic review of the literature with meta-analysis. To match clinical practice, this review was limited to fluid warmers that used contact heating; thus, studies that used radiofrequency or microwave heating were excluded. Twenty-four observational studies were included, 17 of which were the subject of a meta-analysis. A preliminary descriptive analysis indicated that multiple factors can influence the level of hemolysis during blood heating with a liquid warmer, including blood age, anticoagulant type, duration of exposure to heat, stirring the blood during heating, and various elements of the circuit through which blood flows (eg, type of infusion pump with pressure and flow, type of microfilter, and type of tubing). Moreover, the duration between sampling and hemolysis assay was a source of heterogeneity among studies, as were the initial free hemoglobin levels in the various experiments. In general, the increase generated by each of these factors other than temperature appears to have been limited except for blood age, which is an important parameter of hemolysis, the length of exposure to heat, and, in some studies, the type of infusion pump used. Regarding the meta-analysis, at temperatures at or less than 43°C and even up to 45-46°C, it appears that blood heating is safe and causes hemolysis only in clinically negligible proportions. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Investigation of micropump mechanism for medical application (blood transport application)

    NASA Astrophysics Data System (ADS)

    Piterah, N. S. M.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    A microfluidic device is a beneficial device in transporting and controling the flow of fluid in microfluidic system especially in biomedical research and application. This study proposed a valveless micropump design with reciprocating micropumping concept. This micropump mechanism model was specifically designed to overcome hydrodynamic reversibility effectively at low Reynolds number and work on finite pressure loads. The transportation of microfluidic especially biological material such as blood was presented clearly in this micropumping mechanism. The transportation of fluid throughout microchannel with low Reynolds number 16 produced 7.5 m3 maximum net volume of blood pumped from left to right and configured upstroke and downstroke situation during 0.74 seconds and 0.24 seconds respectively.

  5. Implanted Blood-Pressure-Measuring Device

    NASA Technical Reports Server (NTRS)

    Fischell, Robert E.

    1988-01-01

    Arterial pressure compared with ambient bodily-fluid pressure. Implanted apparatus, capable of measuring blood pressure of patient, includes differential-pressure transducer connected to pressure sensor positioned in major artery. Electrical signal is function of differential pressure between blood-pressure sensor and reference-pressure sensor transmitted through skin of patient to recorder or indicator.

  6. Biodynamic Performance of Hyaluronic Acid versus Synovial fluid of the Knee for Osteoarthritic Therapy

    PubMed Central

    Corvelli, Michael; Che, Bernadette; Saeui, Christopher; Singh, Anirudha; Elisseeff, Jennifer

    2015-01-01

    Hyaluronic acid (HA), a natural biomaterial present in healthy joints but depleted in osteoarthritis (OA), has been employed clinically to provide symptomatic relief of joint pain. Joint movement combined with a reduced joint lubrication in osteoarthritic knees can result in increased wear and tear, chondrocyte apoptosis, and inflammation, leading to cascading cartilage deterioration. Therefore, development of an appropriate cartilage model and evaluation for its friction properties with potential lubricants in different conditions is necessary, which can closely resemble a mechanically induced OA cartilage. Additionally, the comparison of different models with and without endogenous lubricating surface zone proteins, such as PRG4 promotes a well-rounded understanding of cartilage lubrication. In this study, we present our findings on the lubricating effects of HA on different articular cartilage model surfaces in comparison to synovial fluid, a physiological lubricating biomaterial. The mechanical testings data demonstrated that HA reduced average static and kinetic friction coefficient values of the cartilage samples by 75% and 70%, respectively. Furthermore, HA mimicked the friction characteristics of freshly harvested natural synovial fluid throughout all tested and modeled OA conditions with no statistically significant difference. These characteristics led us to exclusively identify HA as an effective boundary layer lubricant in the technology that we develop to treat OA [Singh et al. 2104]. PMID:25858258

  7. Influence of film dimensions on film droplet formation.

    PubMed

    Holmgren, Helene; Ljungström, Evert

    2012-02-01

    Aerosol particles may be generated from rupturing liquid films through a droplet formation mechanism. The present work was undertaken with the aim to throw some light on the influence of film dimensions on droplet formation with possible consequences for exhaled breath aerosol formation. The film droplet formation process was mimicked by using a purpose-built device, where fluid films were spanned across holes of known diameters. As the films burst, droplets were formed and the number and size distributions of the resulting droplets were determined. No general relation could be found between hole diameter and the number of droplets generated per unit surface area of fluid film. Averaged over all film sizes, a higher surface tension yielded higher concentrations of droplets. Surface tension did not influence the resulting droplet diameter, but it was found that smaller films generated smaller droplets. This study shows that small fluid films generate droplets as efficiently as large films, and that droplets may well be generated from films with diameters below 1 mm. This has implications for the formation of film droplets from reopening of closed airways because human terminal bronchioles are of similar dimensions. Thus, the results provide support for the earlier proposed mechanism where reopening of closed airways is one origin of exhaled particles.

  8. Fabrication of Artificial Leaf to Develop Fluid Pump Driven by Surface Tension and Evaporation

    NASA Astrophysics Data System (ADS)

    Lee, Minki; Lim, Hosub; Lee, Jinkee

    2017-11-01

    Plants transport water from roots to leaves via xylem through transpiration, which is an evaporation process that occurs at the leaves. During transpiration, negative pressure can be generated by the porous structure of mesophyll cells in the leaves. Here, an artificial leaf mimicking structure using hydrogel, which has a nanoporous structure is fabricated. The cryogel method is used to develop a hierarchy structure on the nano- and microscale in the hydrogel media that is similar to the mesophyll cells and veins of a leaf, respectively. The theoretical model is analyzed to calculate the flow resistance in the artificial leaf, and compare the model with the experimental results. The experiment involves connecting a glass capillary tube at the bottom of the artificial leaf to observe the fluid velocity in the glass capillary tube generated by the negative pressure. The use of silicone oil as fluid instead of water to increase the flow resistance enables the measurement of negative pressure. The negative pressure of the artificial leaf is affected by several variables (e.g., pore size, wettability of the structure). Finally, by decreasing the pore size and increasing the wettability, the maximum negative pressure of the artificial leaf, -7.9 kPa is obtained.

  9. [Postmortem distribution of tetrodotoxin in tissues and body fluids of guinea pigs].

    PubMed

    Liu, Wei; Da, Qing; Shen, Min

    2012-06-01

    To investigate the postmortem distribution of tetrodotoxin in tissues and body fluids of guinea pig, and to provide method and evidence for forensic identification and clinical diagnosis and treatment. Guinea pigs were intragastric administrated with 100, 50, 15 microg/kg tetrodotoxin, respectively. The poisoning symptoms were observed. The samples of heart, liver, spleen, lung, kidney, brain, stomach, intestines, bile, heart blood and urine were collected. The concentrations of tetrodotoxin in tissues and body fluids were measured with liquid chromatography-tandem mass spectrometry (LC-MS/MS). After administrated with tetrodotoxin, all guinea pigs came out poisoning signs including tachypnea, weary and dead finally. Tetrodotoxin concentrations in lung, stomach, intestines and urine were higher, followed by blood, heart and brain. The concentration in bile was the lowest. Postmortem distribution of tetrodotoxin in guinea pig is uneven. The concentration in the lung, stomach, intestines, urine and heart blood are higher, those tissues could be used for diagnosis of tetrodotoxin poisoning.

  10. Postmortem detection of 25I-NBOMe [2-(4-iodo-2,5-dimethoxyphenyl)-N-[(2-methoxyphenyl)methyl]ethanamine] in fluids and tissues determined by high performance liquid chromatography with tandem mass spectrometry from a traumatic death

    PubMed Central

    Poklis, Justin L.; Devers, Kelly G.; Arbefeville, Elise F.; Pearson, Julia M.; Houston, Eric; Poklis, Alphonse

    2014-01-01

    We present a traumatic fatality of a 19-year-old man who had ingested blotter paper containing 25INBOMe [2-(4-iodo-2,5-dimethoxyphenyl)-N-[(2-methoxyphenyl)methyl]ethanamine]. Postmortem specimens were analyzed by high performance liquid chromatography with tandem mass spectrometry (HPLC/MS/MS). Toxicology findings for fluids based upon blood or urine calibrators were as follows: peripheral blood, 405 pg/mL; heart blood, 410 pg/mL; urine, 2.86 ng/mL; and vitreous humor, 99 pg/mL. While findings based upon the method of standard additions were: gastric contents, 7.1 μg total; bile, 10.9 ng/g; brain, 2.54 ng/g and liver, 7.2 ng/g. To our knowledge the presented case is the first postmortem case of 25I-NBOMe intoxication documented by toxicological analysis of tissues and body fluids. PMID:24215811

  11. National guidelines on management of occupational exposure to HIV.

    PubMed

    Rewari, B B; Negi, Shivi

    2009-05-01

    During patient care, the healthcare personnel are at risk of infection of blood-borne pathogens (HIV, HBV, HCV) which is referred to as occupational exposure. Exposure to blood, semen, vaginal secretions, CSF, synovial, pleural, peritoneal, pericardial fluid, amniotic fluid and other body fluids contaminated with visible blood can lead to infection. Steps which are to be followed after occupational exposure are: (1) Step I : First aid following the exposure. (2) Step 2: Establish eligibility for postexposure prophylaxis (PEP). (3) Step 3: Counselling for PEP. (4) Step 4: Prescribe PEP. (5) HIV chemoprophylaxis. (6) Step 6: Follow-up of an exposed person. In order to get timely prophylactic therapy, PEP drugs should be kept available round-the-clock in at least three locations, casualty, ICU and labour room. Every hospital should have a written protocol and SOP for handling occupational exposure. NACO is in the process of launching a national HIV PEP Registry for capturing the cases of occupational exposure to HIV more effectively.

  12. Selective differential human blood bilayer media for isolation of Gardnerella (Haemophilus) vaginalis.

    PubMed Central

    Totten, P A; Amsel, R; Hale, J; Piot, P; Holmes, K K

    1982-01-01

    New selective and differential human blood bilayer agar media with Tween 80 (HBT medium) or without Tween 80 (HB medium), developed for the isolation of Gardnerella (Haemophilus) vaginalis, permitted significantly higher G. vaginalis isolation rates than have been obtained for other media used for this purpose. HB medium consists of a basal layer of Columbia agar base containing colistin and naladixic acid with added amphotericin B and an overlayer of the same composition plus 5% human blood. HBT agar also contains Proteose Peptone No. 3 (Difco Laboratories) and Tween 80 in the basal layer and the overlayer. Both Tween 80 and the bilayer composition enhanced G. vaginalis production of human blood hemolysis, permitting detection of this organism even in the presence of heavy growth of other vaginal flora. The use of HB or HBT medium thus permitted the demonstration that G. vaginalis was present in vaginal fluid from a large percentage (up to 68%) of normal women. However, the concentration of G. vaginalis was found by semiquantitative analysis to be significantly higher in vaginal fluid from women with nonspecific vaginitis than in fluid from normal women. Images PMID:6764766

  13. Evaluation of medical students using the "qi, blood, and fluid" system of Kampo medicine.

    PubMed

    Arai, Makoto; Arai, Katsuhiko; Hioki, Chizuko; Takashi, Masanori; Matsumoto, Kaori; Honda, Masamitsu; Izumi, Shun-ichiro

    2013-04-20

    Although "qi, blood, and fluid" (QBF) is the most important concept for patients in Kampo medicine, there are few studies about the conditions of the QBF system among healthy populations. We used QBF pattern scores to determine whether or not medical students, presumed to be healthy, had any potentially pathological conditions. Six consecutive fourth-year classes totaling 652 medical students evaluated their own QBF conditions using Terasawa's QBF pattern scores. The six conditions: "qi deficiency" (QD), "qi stagnation" (QS), "qi counterflow" (QC), "blood deficiency" (BD), "blood stasis" (BS), and "fluid disturbance" (FD), were categorized according to Terasawa's criteria. The Mann-Whitney U test was used to compare the score differences between the genders, Chi-square test was used to examine gender differences in the QBF diagnoses, and the Spearman's rank-order correlation coefficient analysis was used to analyze the correlation between each category of QBF. In all, 44.6% of the students met at least one diagnostic criterion in the QBF system. QC, BD, BS, and FD were established more in females, and QD and QS were established without gender differences. Most students who were presumed to be healthy were revealed to have some potentially pathological conditions using the QBF system.

  14. Blood Test: Basic Metabolic Panel (BMP)

    MedlinePlus

    ... the body's fluid levels and its acid-base balance. Normal levels of these electrolytes help keep cells in the body working as they should. Blood urea nitrogen (BUN) and creatinine , which are waste products filtered ...

  15. Blood Test: Comprehensive Metabolic Panel (CMP)

    MedlinePlus

    ... the body's fluid levels and its acid-base balance. Normal levels of these electrolytes help keep cells in the body working as they should. Blood urea nitrogen (BUN) and creatinine , which are waste products filtered ...

  16. Blood flow

    NASA Technical Reports Server (NTRS)

    Jones, R. T.

    1976-01-01

    A heuristic treatment of blood flow in the heart and the aorta together with some of the main branches considers the effects of fluid viscosity and vessel elasticity as well as pressure distribution in the typical pulsating flow.

  17. State of the art in fluid and volume therapy : A user-friendly staged concept. English version.

    PubMed

    Rehm, M; Hulde, N; Kammerer, T; Meidert, A S; Hofmann-Kiefer, K

    2017-04-10

    Adequate intraoperative infusion therapy is essential for the perioperative outcome of a patient. Both hypo- and hypervolemia can lead to an increased rate of perioperative complications and to a worse outcome. Perioperative infusion therapy should therefore be needs-based. The primary objective is the maintenance of preoperative normovolemia using a rational infusion strategy. Perioperative fluid losses should be differentiated from volume losses due to surgical bleeding or protein losses into the interstitial space. Fluid loss via urine excretion or insensible perspiration (0.5-1.0 ml/kg/h) should be replaced with balanced, isooncotic, crystalloid infusion solutions in a ratio of 1:1. Volume therapy stage 1: intraoperative volume losses up to a blood loss corresponding to 20% of the patient's total blood volume are compensated for by balanced crystalloids in a ratio of 4-5:1. Stage 2: blood losses exceeding this level are to be treated with isooncotic colloids (preferably balanced) in a 1:1 ratio. In this regard taking into consideration the contraindications, e. g., sepsis, burns, critical illness (usually patients in the intensive care unit), impaired renal function or renal replacement therapy, intracranial hemorrhage, or severe coagulopathy, artificial colloids such as hydroxyethyl starch (HES) can be used perioperatively for volume replacement. Stage 3: if an allogeneic blood transfusion is indicated, blood and blood products are applied in a differentiated manner.

  18. Alternative to Blood Replacement in the Critically Ill.

    PubMed

    Tolich, Deborah J; McCoy, Kelly

    2017-09-01

    This article reviews treatments and strategies that can be used to reduce, or as adjuncts to, blood transfusion to manage blood volumes in patients who are critically ill. Areas addressed include iatrogenic anemia, fluid management, pharmaceutical agents, hemostatic agents, hemoglobin-based oxygen carriers, and management of patients for whom blood is not an option. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A three-dimensional numerical simulation of cell behavior in a flow chamber based on fluid-solid interaction.

    PubMed

    Bai, Long; Cui, Yuhong; Zhang, Yixia; Zhao, Na

    2014-01-01

    The mechanical behavior of blood cells in the vessels has a close relationship with the physical characteristics of the blood and the cells. In this paper, a numerical simulation method was proposed to understand a single-blood cell's behavior in the vessels based on fluid-solid interaction method, which was conducted under adaptive time step and fixed time step, respectively. The main programme was C++ codes, which called FLUENT and ANSYS software, and UDF and APDL acted as a messenger to connect FLUENT and ANSYS for exchanging data. The computing results show: (1) the blood cell moved towards the bottom of the flow chamber in the beginning due to the influence of gravity, then it began to jump up when reached a certain height rather than touching the bottom. It could move downwards again after jump up, the blood cell could keep this way of moving like dancing continuously in the vessels; (2) the blood cell was rolling and deforming all the time; the rotation had oscillatory changes and the deformation became conspicuously when the blood cell was dancing. This new simulation method and results can be widely used in the researches of cytology, blood, cells, etc.

  20. Concomitant bidirectional transport during peritoneal dialysis can be explained by a structured interstitium

    PubMed Central

    Waniewski, Jacek; Flessner, Michael F.; Lindholm, Bengt

    2016-01-01

    Clinical and animal studies suggest that peritoneal absorption of fluid and protein from dialysate to peritoneal tissue, and to blood and lymph circulation, occurs concomitantly with opposite flows of fluid and protein, i.e., from blood to dialysate. However, until now a theoretical explanation of this phenomenon has been lacking. A two-phase distributed model is proposed to explain the bidirectional, concomitant transport of fluid, albumin and glucose through the peritoneal transport system (PTS) during peritoneal dialysis. The interstitium of this tissue is described as an expandable two-phase structure with phase F (water-rich, colloid-poor region) and phase C (water-poor, colloid-rich region) with fluid and solute exchange between them. A low fraction of phase F is assumed in the intact tissue, which can be significantly increased under the influence of hydrostatic pressure and tissue hydration. The capillary wall is described using the three-pore model, and the conditions in the peritoneal cavity are assumed commencing 3 min after the infusion of glucose 3.86% dialysis fluid. Computer simulations demonstrate that peritoneal absorption of fluid into the tissue, which occurs via phase F at the rate of 1.8 ml/min, increases substantially the interstitial pressure and tissue hydration in both phases close to the peritoneal cavity, whereas the glucose-induced ultrafiltration from blood occurs via phase C at the rate of 15 ml/min. The proposed model delineating the phenomenon of concomitant bidirectional transport through PTS is based on a two-phase structure of the interstitium and provides results in agreement with clinical and experimental data. PMID:26945084

  1. Fluid bolus therapy in critically ill children: a survey of practice among paediatric intensive care doctors in Australia and New Zealand.

    PubMed

    Gelbart, Ben; Schlapbach, Luregn; Ganeshalingham, Anusha; Ganu, Subodh; Erickson, Simon; Oberender, Felix; Hoq, Monsurul; Williams, Gary; George, Shane; Festa, Marino

    2018-06-01

    Fluid bolus therapy (FBT) is a widely used intervention in paediatric critical illness. The aim of this study was to describe the attitudes and practices towards FBT of paediatric intensive care doctors in Australia and New Zealand. An internet-based survey of paediatric intensive care doctors in Australia and New Zealand between 7 and 30 November 2016. Paediatric intensive care units with greater than 400 admissions annually. Paediatric intensive care specialists and junior medical staff. Preferences for FBT and markers of fluid responsiveness. There were 106/175 respondents (61%); 0.9% saline and 4% albumin are used frequently or almost always by 86% and 57% of respondents respectively. The preferred volume and duration were 10 mL/kg in less than 10 minutes. The highest rated markers of fluid responsiveness were heart rate and blood pressure - rated as "good" or "very good" by 75% and 58% of respondents respectively. Central venous saturations and serum lactate were the highest rated biochemical markers. The most frequently expected magnitude of change for heart rate and blood pressure was 6-15% by 89% and 76% of respondents respectively. The preferred fluid composition for sepsis, trauma, traumatic brain injury and acute lung injury was 0.9% saline, and 4% albumin for post-operative cardiac surgery. Paediatric intensive care doctors prefer 0.9% saline and 4% albumin for FBT. Heart rate and blood pressure are the most preferred markers to assess fluid responsiveness. Preferences for FBT in specific conditions exist.

  2. Chronic resuscitation after trauma-hemorrhage and acute fluid replacement improves hepatocellular function and cardiac output.

    PubMed

    Remmers, D E; Wang, P; Cioffi, W G; Bland, K I; Chaudry, I H

    1998-01-01

    To determine whether prolonged (chronic) resuscitation has any beneficial effects on cardiac output and hepatocellular function after trauma-hemorrhage and acute fluid replacement. Acute fluid resuscitation after trauma-hemorrhage restores but does not maintain the depressed hepatocellular function and cardiac output. Male Sprague-Dawley rats underwent a 5-cm laparotomy (i.e., trauma was induced) and were bled to and maintained at a mean arterial pressure of 40 mmHg until 40% of maximal bleed-out volume was returned in the form of Ringer's lactate (RL). The animals were acutely resuscitated with RL using 4 times the volume of maximum bleed-out over 60 minutes, followed by chronic resuscitation of 0, 5, or 10 mL/kg/hr RL for 20 hours. Hepatocellular function was determined by an in vivo indocyanine green clearance technique. Hepatic microvascular blood flow was assessed by laser Doppler flowmetry. Plasma levels of interleukin-6 (IL-6) were determined by bioassay. Chronic resuscitation with 5 mL/kg/hr RL, but not with 0 or 10 mL/kg/hr RL, restored cardiac output, hepatocellular function, and hepatic microvascular blood flow at 20 hours after hemorrhage. The regimen above also reduced plasma IL-6 levels. Because chronic resuscitation with 5 mL/kg/hr RL after trauma-hemorrhage and acute fluid replacement restored hepatocellular function and hepatic microvascular blood flow and decreased plasma levels of IL-6, we propose that chronic fluid resuscitation in addition to acute fluid replacement should be routinely used in experimental studies of trauma-hemorrhage.

  3. Effects of Fluid Shear Stress on Cancer Stem Cell Viability

    NASA Astrophysics Data System (ADS)

    Sunday, Brittney; Triantafillu, Ursula; Domier, Ria; Kim, Yonghyun

    2014-11-01

    Cancer stem cells (CSCs), which are believed to be the source of tumor formation, are exposed to fluid shear stress as a result of blood flow within the blood vessels. It was theorized that CSCs would be less susceptible to cell death than non-CSCs after both types of cell were exposed to a fluid shear stress, and that higher levels of fluid shear stress would result in lower levels of cell viability for both cell types. To test this hypothesis, U87 glioblastoma cells were cultured adherently (containing smaller populations of CSCs) and spherically (containing larger populations of CSCs). They were exposed to fluid shear stress in a simulated blood flow through a 125-micrometer diameter polyetheretherketone (PEEK) tubing using a syringe pump. After exposure, cell viability data was collected using a BioRad TC20 Automated Cell Counter. Each cell type was tested at three physiological shear stress values: 5, 20, and 60 dynes per centimeter squared. In general, it was found that the CSC-enriched U87 sphere cells had higher cell viability than the CSC-depleted U87 adherent cancer cells. Interestingly, it was also observed that the cell viability was not negatively affected by the higher fluid shear stress values in the tested range. In future follow-up studies, higher shear stresses will be tested. Furthermore, CSCs from different tumor origins (e.g. breast tumor, prostate tumor) will be tested to determine cell-specific shear sensitivity. National Science Foundation Grant #1358991 supported the first author as an REU student.

  4. Extended Detection of Amphetamine and Methamphetamine in Oral Fluid.

    PubMed

    Andås, Hilde T; Enger, Asle; Øiestad, Åse Marit L; Vindenes, Vigdis; Christophersen, Asbjørg S; Huestis, Marilyn A; Øiestad, Elisabeth L

    2016-02-01

    Amphetamine and methamphetamine are popular drugs of abuse worldwide and are important components of drug monitoring programs. Windows of detection for amphetamine and methamphetamine in oral fluid after high doses have not been investigated. Repeated high-dose ingestions are likely to cause positive samples for extended periods. Common routes of administration of amphetamine/methamphetamine in Norway are oral intake or injection. The aim of this study was to investigate windows of detection for amphetamine and methamphetamine in oral fluid from drug addicts under sustained abstinence during detoxification. Twenty-five patients admitted to a closed detoxification unit were included in this study. Oral fluid samples were collected daily in the morning and evening, and urine every morning for 10 days. A blood sample was drawn during the first 5 days after admission if the patient consented. Oral fluid results were compared with urine results to determine whether a new ingestion occurred. Oral fluid was collected with the Intercept oral fluid collection device. In-house cutoff concentrations for amphetamine and methamphetamine were 6.8 and 7.5 mcg/L, respectively, in oral fluid, and 135 and 149 mcg/L, respectively, in urine. Amphetamines were detected in 11 oral fluid, 5 urine, and 2 blood specimens from 25 patients. Patients self-reported amphetamines intake of up to 0.5-2 g daily. Windows of detection for amphetamine and methamphetamine in oral fluid were up to 8 days, longer than in urine at the applied cutoff values. These data confirm that oral fluid is a viable alternative to urine for monitoring amphetamine abuse, and that these substances might be detected in oral fluid for at least 1 week after ingestion of high doses. Such long detection times were, as far as we are aware, never reported previously for oral fluid amphetamines.

  5. Liberal Versus Restrictive Intravenous Fluid Therapy for Early Septic Shock: Rationale for a Randomized Trial.

    PubMed

    Self, Wesley H; Semler, Matthew W; Bellomo, Rinaldo; Brown, Samuel M; deBoisblanc, Bennett P; Exline, Matthew C; Ginde, Adit A; Grissom, Colin K; Janz, David R; Jones, Alan E; Liu, Kathleen D; Macdonald, Stephen P J; Miller, Chadwick D; Park, Pauline K; Reineck, Lora A; Rice, Todd W; Steingrub, Jay S; Talmor, Daniel; Yealy, Donald M; Douglas, Ivor S; Shapiro, Nathan I

    2018-05-09

    Prompt intravenous fluid therapy is a fundamental treatment for patients with septic shock. However, the optimal approach for administering intravenous fluid in septic shock resuscitation is unknown. Two competing strategies are emerging: a liberal fluids approach, consisting of a larger volume of initial fluid (50 to 75 mL/kg [4 to 6 L in an 80-kg adult] during the first 6 hours) and later use of vasopressors, versus a restrictive fluids approach, consisting of a smaller volume of initial fluid (≤30 mL/kg [≤2 to 3 L]), with earlier reliance on vasopressor infusions to maintain blood pressure and perfusion. Early fluid therapy may enhance or maintain tissue perfusion by increasing venous return and cardiac output. However, fluid administration may also have deleterious effects by causing edema within vital organs, leading to organ dysfunction and impairment of oxygen delivery. Conversely, a restrictive fluids approach primarily relies on vasopressors to reverse hypotension and maintain perfusion while limiting the administration of fluid. Both strategies have some evidence to support their use but lack robust data to confirm the benefit of one strategy over the other, creating clinical and scientific equipoise. As part of the National Heart, Lung, and Blood Institute Prevention and Early Treatment of Acute Lung Injury Network, we designed a randomized clinical trial to compare the liberal and restrictive fluids strategies, the Crystalloid Liberal or Vasopressor Early Resuscitation in Sepsis trial. The purpose of this article is to review the current literature on approaches to early fluid resuscitation in adults with septic shock and outline the rationale for the upcoming trial. Copyright © 2018 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.

  6. Occupational Exposure of Shiraz Dental Students to Patients’ Blood and Body Fluid

    PubMed Central

    Shaghaghian, Soheila; Golkari, Ali; Pardis, Soheil; Rezayi, Ali

    2015-01-01

    Statement of the Problem Exposure to patients’ blood and body fluids would prone the dental students to the risk of blood borne infections. Several studies have shown a high prevalence of these exposures in dental settings particularly in developing countries. However, few studies have evaluated the epidemiology of these exposures in dental students in Iran. Purpose To assess the epidemiology of occupational exposures among dental students and consequently designing the appropriate interventions in order to prevent these exposures. Materials and Method In this cross-sectional study performed during March to June 2011, all 191 Shiraz clinical dental students were asked to complete a self-administered questionnaire. This questionnaire included demographic information and experience of sharp injuries and mucocutaneous contaminations. Chi square and t-test were employed to evaluate the risk factors of exposure. Results 80%of the participants were exposed to the patients’ blood or body fluids during their clinical course. No association was found between the exposure and demographic factors. Injection needle and recapping were the most common causes of these injuries. The most common sites that were injured and caused mucocutaneous contamination were finger and face, respectively. The most frequent activity causing contamination was using high-speed rotary instruments. Only 6.4% of the exposures had been reported to the related authorities and the remains were underreported. Conclusion Blood and body fluid exposure in dental setting is common and a lot of them are not reported. To reduce the hazards of these exposures, infection control authorities should design interventions especially for mentioned high-risk conditions. They should change dental students’ behavior especially regarding not recapping injection needles and using eyewear. Dental schools seem to need a management center and a standard protocol for following up the exposures. PMID:26331151

  7. Pharmacokinetics of ethanol and its metabolite, acetaldehyde, and fetolethality in the third-trimester pregnant guinea pig for oral administration of acute, multiple-dose ethanol.

    PubMed

    Clarke, D W; Steenaart, N A; Slack, C J; Brien, J F

    1986-08-01

    The pharmacokinetics of ethanol and its metabolite, acetaldehyde, were determined in the third-trimester pregnant guinea pig (56-59 days gestation) for oral intubation of four doses of 1 g ethanol/kg maternal body weight, administered at 1-h intervals. Animals (n = 4-7) were sacrificed at each of selected times during the 26-h study. Ethanol and acetaldehyde concentrations were determined by headspace gas-liquid chromatography. The maternal and fetal blood ethanol concentration-time curves were virtually superimposable, which indicated unimpeded bidirectional placental transfer of ethanol in the maternal-fetal unit. The blood and brain ethanol concentrations were similar in each of the maternal and fetal compartments during the study, which indicated rapid equilibrium distribution of ethanol. There was accumulation of ethanol in the amniotic fluid resulting in higher ethanol concentration compared with maternal and fetal blood during the elimination phase, which indicated that the amniotic fluid may serve as a reservoir for ethanol in utero. Acetaldehyde was measurable in all the biological fluids and tissues at concentrations that were at least 1,000-fold less than the respective ethanol concentrations and were variable. There was ethanol-induced fetolethality that was delayed and variable among animals, and was 55% at 23 h. At this time interval, the ethanol concentrations in maternal blood and brain, fetal brain, and amniotic fluid were 35- to 53-fold greater and the acetaldehyde concentrations in maternal blood and fetal brain were four- to five-fold higher in the animals with dead fetuses compared with the guinea pigs with live litters. These data indicated that decreased ethanol elimination from the maternal-fetal unit was related temporally to the fetolethality.

  8. Reversal of Progressive Conscious Disturbance with Epidural Blood Patch for Cerebrospinal Fluid Leakage at C2 Level.

    PubMed

    Lai, Yi-Chen; Chia, Yuan-Yi; Lien, Wei-Hung

    2017-03-01

    Intracranial hypotension syndrome (IHS) is generally caused by cerebrospinal fluid (CSF) leakage. Complications include bilateral subdural hygroma or haematoma and herniation of the cerebellar tonsils. Epidural blood patch (EBP) therapy is indicated if conservative treatment is ineffective. We reported the case of a 46-year-old man with a history of postural headache and dizziness. The patient was treated with bed rest and daily hydration with 2000 mL of fluid for 2 weeks. However, dizziness and headache did not resolve, and he became drowsy and disoriented with incomprehensible speech. Magnetic resonance imaging demonstrated diffuse dural enhancement on the postcontrast study, sagging of the midbrain, and CSF leakage over right lateral posterior thecal sac at C2 level. We performed EBP at the level of T10-T11. We injected 14 mL of autologous blood slowly in the Trendelenburg position. Within 30 minutes, he became alert and oriented to people, place, and time. We chose thoracic EBP as first line treatment in consideration of the risk of cervical EBP such as spinal cord and nerve root compression or puncture, chemical meningitis. Also we put our patient in Trendelenburg position to make blood travel towards the site of the leak. Untreated IHS may delay the course of resolution and affect the patient's consciousness. Delivery of EBP via an epidural catheter inserted from the thoracic spine is familiar with most of anesthesiologists. It can be a safe and effective treatment for patients with IHS caused by CSF leak even at C2.Key words: Anaesthetic techniques, regional, thoracic; cerebrospinal fluid leakage; epidural blood patch; heavily T2-weighted magnetic resonance myelography; intracranial hypotension syndrome; Trendelenburg position.

  9. Cardiovascular response to lower body negative pressure stimulation before, during, and after space flight

    NASA Technical Reports Server (NTRS)

    Baisch, F.; Beck, L.; Blomqvist, G.; Wolfram, G.; Drescher, J.; Rome, J. L.; Drummer, C.

    2000-01-01

    BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.

  10. Penetration and distribution of gadolinium-based contrast agents into the cerebrospinal fluid in healthy rats: a potential pathway of entry into the brain tissue.

    PubMed

    Jost, Gregor; Frenzel, Thomas; Lohrke, Jessica; Lenhard, Diana Constanze; Naganawa, Shinji; Pietsch, Hubertus

    2017-07-01

    Signal hyperintensity on unenhanced MRI in certain brain regions has been reported after multiple administrations of some, but not all, gadolinium-based contrast agents (GBCAs). One potential initial pathway of GBCA entry into the brain, infiltration from blood into the cerebrospinal fluid (CSF), was systematically evaluated in this preclinical study. GBCA infiltration and distribution in the CSF were investigated in healthy rats using repeated fluid-attenuated MRI up to 4 h after high-dose (1.8 mmol/kg) administration of six marketed and one experimental GBCA. Additionally, gadolinium measurements in CSF, blood and brain tissue samples (after 24 h) were performed using inductively coupled plasma mass spectrometry. Enhanced MRI signals in the CSF spaces with similar distribution kinetics were observed for all GBCAs. No substantial differences in the gadolinium concentrations among the marketed GBCAs were found in the CSF, blood or brain tissue. After 4.5 h, the concentration in the CSF was clearly higher than in blood but was almost completely cleared and lower than the brain tissue concentration after 24 h. In contrast to the brain signal hyperintensities, no differences in penetration and distribution into the CSF of healthy rats exist among the marketed GBCAs. • Gadolinium-based contrast agents can cross the blood-CSF barrier. • Fluid-attenuated MRI shows GBCA distribution with CSF flow. • GBCA structure and physicochemical properties do not impact CSF penetration and distribution. • GBCA clearance from CSF was almost complete within 24 h in rats. • CSF is a potential pathway of GBCA entry into the brain.

  11. Dynamical clustering of red blood cells in capillary vessels.

    PubMed

    Boryczko, Krzysztof; Dzwinel, Witold; Yuen, David A

    2003-02-01

    We have modeled the dynamics of a 3-D system consisting of red blood cells (RBCs), plasma and capillary walls using a discrete-particle approach. The blood cells and capillary walls are composed of a mesh of particles interacting with harmonic forces between nearest neighbors. We employ classical mechanics to mimic the elastic properties of RBCs with a biconcave disk composed of a mesh of spring-like particles. The fluid particle method allows for modeling the plasma as a particle ensemble, where each particle represents a collective unit of fluid, which is defined by its mass, moment of inertia, translational and angular momenta. Realistic behavior of blood cells is modeled by considering RBCs and plasma flowing through capillaries of various shapes. Three types of vessels are employed: a pipe with a choking point, a curved vessel and bifurcating capillaries. There is a strong tendency to produce RBC clusters in capillaries. The choking points and other irregularities in geometry influence both the flow and RBC shapes, considerably increasing the clotting effect. We also discuss other clotting factors coming from the physical properties of blood, such as the viscosity of the plasma and the elasticity of the RBCs. Modeling has been carried out with adequate resolution by using 1 to 10 million particles. Discrete particle simulations open a new pathway for modeling the dynamics of complex, viscoelastic fluids at the microscale, where both liquid and solid phases are treated with discrete particles. Figure A snapshot from fluid particle simulation of RBCs flowing along a curved capillary. The red color corresponds to the highest velocity. We can observe aggregation of RBCs at places with the most stagnant plasma flow.

  12. Cytokine signalling in rat pulp interstitial fluid and transcapillary fluid exchange during lipopolysaccharide-induced acute inflammation

    PubMed Central

    Bletsa, Athanasia; Berggreen, Ellen; Fristad, Inge; Tenstad, Olav; Wiig, Helge

    2006-01-01

    The dental pulp consists of loose connective tissue encased in rigid dentinal walls. Because of its topography the tissue has low interstitial compliance and limited capacity to expand during fluid volume changes. Due to limitations regarding access to interstitial fluid, basic knowledge on transcapillary fluid transport parameters is lacking for this organ. The scope of this project was dual: first we aimed at establishing a method for isolation of pulp interstitial fluid (IF), and second we applied the method in rats subjected to lipopolysaccharide (LPS)-induced endotoxaemia. The aim was to measure colloid osmotic pressure (COP) and pro-inflammatory cytokines in the pulp IF during acute inflammation. Fluid volumes and pulpal blood flow (PBF) were measured to obtain more information about microcirculatory changes that take place in this pulpitis model. By centrifugation of incisor pulp at 239 g we were able to extract fluid representative for IF. Pulp IF had a relative high control COP (∼83% of plasma COP) and was similar to plasma COP 3 h after LPS challenge. The pulp exhibited a high content of IF (0.60 ± 0.03 ml (g wet weight)−1) and a vascular volume of 0.03 ± 0.01 ml (g w.w.)−1 No differences were observed in the distribution of fluid volumes after 1.5 and 3 h LPS exposure. PBF and systemic blood pressure dropped significantly after LPS administration. PBF remained low whereas systemic blood pressure was re-established during the 3-h period, implying organ dysfunction. There was a differential pattern of cytokine expression in pulp IF and serum with cytokines such as IL-1α, IL-1β and TNF-α locally produced, whereas others such as IFN-γ and IL-6 were produced systemically and probably spilled over to the pulp IF after LPS exposure. Our findings show that pulp IF can be isolated by centrifugation and that this method is useful when studying fluid balance and extracellular signalling mechanisms in the dental pulp in normal and pathological conditions. PMID:16527857

  13. Regulation of amniotic fluid volume: mathematical model based on intramembranous transport mechanisms

    PubMed Central

    Anderson, Debra F.; Cheung, Cecilia Y.

    2014-01-01

    Experimentation in late-gestation fetal sheep has suggested that regulation of amniotic fluid (AF) volume occurs primarily by modulating the rate of intramembranous transport of water and solutes across the amnion into underlying fetal blood vessels. In order to gain insight into intramembranous transport mechanisms, we developed a computer model that allows simulation of experimentally measured changes in AF volume and composition over time. The model included fetal urine excretion and lung liquid secretion as inflows into the amniotic compartment plus fetal swallowing and intramembranous absorption as outflows. By using experimental flows and solute concentrations for urine, lung liquid, and swallowed fluid in combination with the passive and active transport mechanisms of the intramembranous pathway, we simulated AF responses to basal conditions, intra-amniotic fluid infusions, fetal intravascular infusions, urine replacement, and tracheoesophageal occlusion. The experimental data are consistent with four intramembranous transport mechanisms acting in concert: 1) an active unidirectional bulk transport of AF with all dissolved solutes out of AF into fetal blood presumably by vesicles; 2) passive bidirectional diffusion of solutes, such as sodium and chloride, between fetal blood and AF; 3) passive bidirectional water movement between AF and fetal blood; and 4) unidirectional transport of lactate into the AF. Further, only unidirectional bulk transport is dynamically regulated. The simulations also identified areas for future study: 1) identifying intramembranous stimulators and inhibitors, 2) determining the semipermeability characteristics of the intramembranous pathway, and 3) characterizing the vesicles that are the primary mediators of intramembranous transport. PMID:25186112

  14. FDA’s Nozzle Numerical Simulation Challenge: Non-Newtonian Fluid Effects and Blood Damage

    PubMed Central

    Trias, Miquel; Arbona, Antonio; Massó, Joan; Miñano, Borja; Bona, Carles

    2014-01-01

    Data from FDA’s nozzle challenge–a study to assess the suitability of simulating fluid flow in an idealized medical device–is used to validate the simulations obtained from a numerical, finite-differences code. Various physiological indicators are computed and compared with experimental data from three different laboratories, getting a very good agreement. Special care is taken with the derivation of blood damage (hemolysis). The paper is focused on the laminar regime, in order to investigate non-Newtonian effects (non-constant fluid viscosity). The code can deal with these effects with just a small extra computational cost, improving Newtonian estimations up to a ten percent. The relevance of non-Newtonian effects for hemolysis parameters is discussed. PMID:24667931

  15. Bovine milk exosome proteome

    USDA-ARS?s Scientific Manuscript database

    Exosomes are 40-100 nm membrane vesicles of endocytic origin and are found in blood, urine, amniotic fluid, bronchoalveolar lavage (BAL) fluid, as well as human and bovine milk. Exosomes are extracellular organelles important in intracellular communication/signaling, immune function, and biomarkers ...

  16. How you get HIV/AIDS

    MedlinePlus

    How you get HIV/AIDS Which body fluids contain HIV? HIV is a virus that lives in blood and other fluids in the body. Moving ... answers to any questions you have about HIV/AIDS. Your public health department and health care provider ...

  17. The Clinical Significance of Eosinophils in the Amniotic Fluid in Preterm Labor

    PubMed Central

    ROMERO, ROBERTO; KUSANOVIC, JUAN PEDRO; GOMEZ, RICARDO; LAMONT, RONALD; BYTAUTIENE, EGLE; GARFIELD, ROBERT E.; MITTAL, POOJA; HASSAN, SONIA S.; YEO, LAMI

    2012-01-01

    Objective White blood cells are not traditionally considered to be normally present in amniotic fluid. This study was conducted after the observation that a patient with preterm labor and intact membranes had eosinophils as a predominant cell in the amniotic fluid, and had an episode of asthma during the index pregnancy. The goal of this study was to determine whether women presenting with preterm labor with eosinophils in the amniotic fluid had a different outcome than those without eosinophils as the predominant white blood cell in the amniotic cavity. Methods This retrospective case-control study included women who presented with preterm labor and intact membranes between 24 and 34 weeks of gestation. Patients underwent an amniocentesis shortly after admission for the assessment of the microbiologic status of the amniotic cavity and/or fetal lung maturity. Amniotic fluid was cultured for aerobic and anaerobic bacteria as well as genital mycoplasmas. Cytologic studies included amniotic fluid white blood cell count and differential, which was performed on cytocentrifuged specimens. Patients with microbial invasion of the amniotic cavity and/or a white blood cell count >20 cells/mm3 were excluded from the study. Cases were defined as women in whom the differential contained >20% of eosinophils. Controls were selected among women with an amniotic fluid eosinophil count ≤20% and matched for gestational age at amniocentesis. The analysis was conducted with non-parametric statistics. Results The study population consisted of 10 cases and 50 controls. Gestational age and cervical dilatation at admission were similar in both groups. Cases had a lower gestational age at delivery than controls [34.6 weeks, inter-quartile range (IQR) 32–37.3 weeks vs. 38.0 weeks, IQR 35–40 weeks, respectively; p=0.018]. The prevalence of preterm delivery ≤35 weeks was higher among patients who had >20% eosinophils than in the control group [50% (5/10) vs. 18% (9/50), respectively; p=0.029]. Similar results were observed for delivery at <37 weeks [Cases: 70% (7/10) vs. Controls: 36% (18/50); p=0.046]. Conclusions Women with preterm labor and intact membranes who have a large proportion of eosinophils in the amniotic fluid are at an increased risk for spontaneous preterm delivery. These patients may have had an episode of preterm labor related to a type I hypersensitivity reaction. PMID:19900034

  18. Activated Monocytes Enhance Platelet-Driven Contraction of Blood Clots via Tissue Factor Expression.

    PubMed

    Peshkova, Alina D; Le Minh, Giang; Tutwiler, Valerie; Andrianova, Izabella A; Weisel, John W; Litvinov, Rustem I

    2017-07-11

    Platelet-driven reduction in blood clot volume (clot contraction or retraction) has been implicated to play a role in hemostasis and thrombosis. Although these processes are often linked with inflammation, the role of inflammatory cells in contraction of blood clots and thrombi has not been investigated. The aim of this work was to study the influence of activated monocytes on clot contraction. The effects of monocytes were evaluated using a quantitative optical tracking methodology to follow volume changes in a blood clot formed in vitro. When a physiologically relevant number of isolated human monocytes pre-activated with phorbol-12-myristate-13-acetate (PMA) were added back into whole blood, the extent and rate of clot contraction were increased compared to addition of non-activated cells. Inhibition of tissue factor expression or its inactivation on the surface of PMA-treated monocytes reduced the extent and rate of clot contraction back to control levels with non-activated monocytes. On the contrary, addition of tissue factor enhanced clot contraction, mimicking the effects of tissue factor expressed on the activated monocytes. These data suggest that the inflammatory cells through their expression of tissue factor can directly affect hemostasis and thrombosis by modulating the size and density of intra- and extravascular clots and thrombi.

  19. Mass spectrometry-based cDNA profiling as a potential tool for human body fluid identification.

    PubMed

    Donfack, Joseph; Wiley, Anissa

    2015-05-01

    Several mRNA markers have been exhaustively evaluated for the identification of human venous blood, saliva, and semen in forensic genetics. As new candidate human body fluid specific markers are discovered, evaluated, and reported in the scientific literature, there is an increasing trend toward determining the ideal markers for cDNA profiling of body fluids of forensic interest. However, it has not been determined which molecular genetics-based technique(s) should be utilized to assess the performance of these markers. In recent years, only a few confirmatory, mRNA/cDNA-based methods have been evaluated for applications in body fluid identification. The most frequently described methods tested to date include quantitative polymerase chain reaction (qPCR) and capillary electrophoresis (CE). However these methods, in particular qPCR, often favor narrow multiplex PCR due to the availability of a limited number of fluorescent dyes/tags. In an attempt to address this technological constraint, this study explored matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) for human body fluid identification via cDNA profiling of venous blood, saliva, and semen. Using cDNA samples at 20pg input phosphoglycerate kinase 1 (PGK1) amounts, body fluid specific markers for the candidate genes were amplified in their corresponding body fluid (i.e., venous blood, saliva, or semen) and absent in the remaining two (100% specificity). The results of this study provide an initial indication that MALDI-TOF MS is a potential fluorescent dye-free alternative method for body fluid identification in forensic casework. However, the inherent issues of low amounts of mRNA, and the damage caused to mRNA by environmental exposures, extraction processes, and storage conditions are important factors that significantly hinder the implementation of cDNA profiling into forensic casework. Published by Elsevier Ireland Ltd.

  20. [Individualized fluid-solid coupled model of intracranial aneurysms based on computed tomography angiography data].

    PubMed

    Wang, Fuyu; Xu, Bainan; Sun, Zhenghui; Liu, Lei; Wu, Chen; Zhang, Xiaojun

    2012-10-01

    To establish an individualized fluid-solid coupled model of intracranial aneurysms based on computed tomography angiography (CTA) image data. The original Dicom format image data from a patient with an intracranial aneurysm were imported into Mimics software to construct the 3D model. The fluid-solid coupled model was simulated with ANSYS and CFX software, and the sensitivity of the model was analyzed. The difference between the rigid model and fluid-solid coupled model was also compared. The fluid-solid coupled model of intracranial aneurysm was established successfully, which allowed direct simulation of the blood flow of the intracranial aneurysm and the deformation of the solid wall. The pressure field, stress field, and distribution of Von Mises stress and deformation of the aneurysm could be exported from the model. A small Young's modulus led to an obvious deformation of the vascular wall, and the walls with greater thicknesses had smaller deformations. The rigid model and the fluid-solid coupled model showed more differences in the wall shear stress and blood flow velocity than in pressure. The fluid-solid coupled model more accurately represents the actual condition of the intracranial aneurysm than the rigid model. The results of numerical simulation with the model are reliable to study the origin, growth and rupture of the aneurysms.

  1. Pancreatic Cystic Fluid Reference Set — EDRN Public Portal

    Cancer.gov

    The proposed reference set will be designed to evaluate biomarkers for the following applications aimed at determining whether a patient would benefit from surgical resection of their cystic lesion: 1.   Distinguish between pancreatic cysts that have high-malignant potential and cysts that have low or no malignant potential at time of endoscopic ultrasound evaluation. a.   By analysis of blood b.   By analysis of pancreatic cystic fluid 2.   Distinguish between cysts that have any malignant potential (high and low) and cysts that have no malignant potential (benign lesions) at time of endoscopic ultrasound evaluation. a.   By analysis of blood b.   By analysis of pancreatic cystic fluid 3.   Distinguish between a cyst that is mucinous (malignant potential) or non-mucinous (no malignant potential) at time of endoscopic ultrasound evaluation. a.   By analysis of blood b.   By analysis of pancreatic cystic fluid 4.   Distinguish between pancreatic cysts that have high-malignant potential and cysts that have low or no malignant potential at time of evaluation in surgery clinic. a.   By analysis of blood 5.   Distinguish between cysts that have any malignant potential (high and low) and cysts that have no malignant potential (benign lesions) at time of evaluation in surgery clinic. a.   By analysis of blood 6.   Distinguish between a cyst that is mucinous (malignant potential) or non-mucinous (no malignant potential) at time of evaluation in surgery clinic. a.   By analysis of blood If successful in meeting these afore-mentioned objectives, these results can then be used in the development of future studies at identifying the need for additional evaluation (i.e., endoscopic ultrasound with fine needle aspiration) of an incidental cyst

  2. Anaesthesia for 1131 patients undergoing proximal femoral fracture repair: a retrospective, observational study of effects on blood pressure, fluid administration and perioperative anaemia.

    PubMed

    Wood, R J; White, S M

    2011-11-01

    Intra-operative hypotension is a frequent occurrence during anaesthesia for hip fracture surgery in older patients with co-morbidities. We analysed retrospective data from the Brighton Hip Fracture Database to determine the intra-operative fall in systolic blood pressure, and the incidence of absolute (lowest systolic blood pressure < 90 mmHg) and relative (> 20% fall in systolic blood pressure from baseline) hypotension during general or spinal anaesthesia among 1131 non-consecutive patients with hip fracture. General anaesthesia for 489 patients (43.2%) produced a greater mean (SD) fall in systolic blood pressure than spinal anaesthesia for 578 patients (51.1%): 34.2% (13.0%) vs 29.7% (10.8%), respectively (p < 0.0001), mean difference 4.5% (95% CI 3.1-5.9%), and was associated with greater mean (SD) intra-operative fluid administration (1555 (801) ml vs 1375 (621) ml, respectively, p < 0.0001). We observed a correlation between the volume of subarachnoid hyperbaric bupivacaine 0.5% and fall in systolic blood pressure (p = 0.004): compared with patients receiving > 1.5 ml (n = 463), fewer patients receiving ≤ 1.5 ml bupivacaine 0.5% (n = 97) experienced episodes of absolute (31.1% vs 11.3%, p < 0.0001) or relative (83.9% vs 26.8%, p < 0.0001) hypotension. Both mean (SD) intravenous fluid administration (1097 ml (439) vs 1431 ml (638), p < 0.0001) and mean peri-operative fall in haemoglobin concentration (2.1 (1.8) g.dl(-1) vs 2.6 (1.7) g.dl(-1), p = 0.009) were lower in the low-dose spinal group. If these data are confirmed by other researchers, intra-operative hypotension (and consequent haemodilution secondary to reactive fluid administration) in this patient group may be reduced by the simple expedient of administering more cautious general anaesthesia, or reduced volumes of subarachnoid local anaesthetic. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  3. Magnetorheological Fluids-Earth Applications Video

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Principal investigator Alice Gast describes magnetorheological (MR) fluids and how they differ from other fluids, such as blood or milk. Gast is the principal investigator for Investigating the structure of Paramagnetic Aggregates from Colloidal Emulsions (InSPACE), which was conducted by the Expedition 6 crew onboard the International Space Station (ISS). The goal of inSPACE is to determine the true three-dimensional (3-D) low energy (equilibrium) structure of the MR fluids in a periodically interrupted magnetic field. Applications for MR fluids could include electrical clutches, brakes, robotic devices, seat suspension systems, and shock absorbers.

  4. Changes in body fluid compartments on re-induction to high altitude and effect of diuretics

    NASA Astrophysics Data System (ADS)

    Singh, M. V.; Rawal, S. B.; Tyagi, A. K.; Bhagat, Maj J. K.; Parshad, R.; Divekar, H. M.

    1988-03-01

    Studies were carried out in 29 healthy young adults in the Indian Army stationed in the plains and posted at an elevation of 3500 m for more than 6 months. After exposure to a low elevation in Delhi (260 m) for 3 weeks they were reinduced to a height of 3500 m. The subjects were divided into three groups, each of which was treated with either placebo or acetazolamide or spironolactone. The drug treatment was started immediately after their landing at high altitude and continued for 2 days only. Total body water, extracellular fluid, intracellular fluid, plasma volume, blood pH, PaO2, PaCO2 and blood viscosity were determined on exposure at Delhi and on re-induction to high altitude. Plasma volume was increased after the descent from high altitude and remained high for up to 21 day's study. This increased plasma volume may have some significance in the pathogenesis of pulmonary oedema. Total body water and intracellular fluid content were increased at 260 m elevation, while extracellular fluid decreased. On re-induction there was a decrease in total body water with no change in the extracellular fluid content.

  5. Anthropometric changes and fluid shifts

    NASA Technical Reports Server (NTRS)

    Thornton, W. E.; Hoffler, G. W.; Rummel, J. A.

    1974-01-01

    Several observations of body size, shape, posture, and configuration were made to document changes resulting from direct effects of weightlessness during the Skylab 4 mission. After the crewmen were placed in orbit, a number of anatomical and anthropometric changes occurred including a straightening of the thoracolumbar spine, a general decrease in truncal girth, and an increase in height. By the time of the earliest in-flight measurement on mission day 3, all crewmen had lost more than two liters of extravascular fluid from the calf and thigh. The puffy facies, the bird legs effect, the engorgement of upper body veins, and the reduced volume of lower body veins were all documented with photographs. Center-of-mass measurements confirmed a fluid shift cephalad. This shift remained throughout the mission until recovery, when a sharp reversal occurred; a major portion of the reversal was completed in a few hours. The anatomical changes are of considerable scientific interest and of import to the human factors design engineer, but the shifts of blood and extravascular fluid are of more consequence. It is hypothesized that the driving force for the fluid shift is the intrinsic and unopposed lower limb elasticity that forces venous blood and then other fluid cephalad.

  6. Occurrence of bacteria and polymorphonuclear leukocytes in fetal compartments at parturition; relationships with foal and mare health in the peripartum period.

    PubMed

    Hemberg, E; Einarsson, S; Kútvölgyi, G; Lundeheim, N; Bagge, E; Båverud, V; Jones, B; Morrell, J M

    2015-07-01

    This study investigated the relationship of the health of the newborn foal and (1) number of polymorphonuclear leukocytes (PMNLs) in the amniotic fluid, (2) bacteria present in the amniotic fluid and the venous umbilical blood, and (3) bacteria present in the uterus of the newly foaled mare. A further aim was to investigate relationships between the bacteriologic findings in the amniotic fluid, umbilical blood, and uterus postpartum. Samples were taken from 50 Standardbred trotter foaling mares from a well-managed stud in Sweden. Parturition was spontaneous in all cases. Length of pregnancy, parturition and postpartum complications, health status of the foal, the time between foaling and the expulsion of the placenta, and the number of postfoaling mares becoming pregnant after insemination were recorded. Amniotic fluid was collected when the amniotic vesicle was clearly visible; it was analyzed for bacteriology and occurrence of PMNLs. Umbilical blood was analyzed for the presence of bacteria and the concentration of serum amyloid A. The uterus of the mare was swabbed for bacteriology 6 to 17 hours postpartum. A blood sample was taken from the foal before administering plasma. The foals were divided into two groups: group 1 required up to 2 hours to rise after birth (≤2 hours; 31 foals) and group 2 required more than two hours (>2 hours; 19 foals). The length of gestation varied between 332 and 356 days; there was no significant difference in gestation length between the two foal groups. Partus and postpartum complications occurred in a significantly higher proportion of mares giving birth to group 2 foals than group 1 foals (P = 0.02), although uterine culture postpartum and the subsequent pregnancy rate per season were not different between the groups. Compromised health status was significantly higher among foals belonging to group 2 than group 1 (P = 0.001). Most of the amniotic samples contained 5% or less PMNLs. Only three samples contained more than 30% PMNLs; group 2 foals had the highest percentage of PMNLs. Bacterial growth was found in both amniotic fluid (57%) and umbilical blood (35%) in mares irrespective of whether their foals were healthy or compromised. Coagulase-negative staphylococci were the most frequent bacteria. There were no differences in bacterial occurrence in amniotic fluid or in umbilical blood between the two foal groups. Copyright © 2015 Elsevier Inc. All rights reserved.

  7. A method for monitoring of oxygen saturation changes in brain tissue using diffuse reflectance spectroscopy.

    PubMed

    Rejmstad, Peter; Johansson, Johannes D; Haj-Hosseini, Neda; Wårdell, Karin

    2017-03-01

    Continuous measurement of local brain oxygen saturation (SO 2 ) can be used to monitor the status of brain trauma patients in the neurocritical care unit. Currently, micro-oxygen-electrodes are considered as the "gold standard" in measuring cerebral oxygen pressure (pO 2 ), which is closely related to SO 2 through the oxygen dissociation curve (ODC) of hemoglobin, but with the drawback of slow in response time. The present study suggests estimation of SO 2 in brain tissue using diffuse reflectance spectroscopy (DRS) for finding an analytical relation between measured spectra and the SO 2 for different blood concentrations. The P 3 diffusion approximation is used to generate a set of spectra simulating brain tissue for various levels of blood concentrations in order to estimate SO 2 . The algorithm is evaluated on optical phantoms mimicking white brain matter (blood volume of 0.5-2%) where pO 2 and temperature is controlled and on clinical data collected during brain surgery. The suggested method is capable of estimating the blood fraction and oxygen saturation changes from the spectroscopic signal and the hemoglobin absorption profile. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Improved drainage with active chest tube clearance.

    PubMed

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Perioperative fluid management: comparison of high, medium and low fluid volume on tissue oxygen pressure in the small bowel and colon.

    PubMed

    Hiltebrand, L B; Pestel, G; Hager, H; Ratnaraj, J; Sigurdsson, G H; Kurz, A

    2007-11-01

    Insufficient blood flow and oxygenation in the intestinal tract is associated with increased incidence of postoperative complications after bowel surgery. High fluid volume administration may prevent occult regional hypoperfusion and intestinal tissue hypoxia. We tested the hypothesis that high intraoperative fluid volume administration increases intestinal wall tissue oxygen pressure during laparotomy. In all, 27 pigs were anaesthetized, ventilated and randomly assigned to one of the three treatment groups (n = 9 in each) receiving low (3 mL kg-1 h-1), medium (7 mL kg-1 h-1) or high (20 mL kg-1 h-1) fluid volume treatment with lactated Ringer's solution. All animals received 30% and 100% inspired oxygen in random order. Cardiac index was measured with thermodilution and tissue oxygen pressure with a micro-oximetry system in the jejunum and colon wall and subcutaneous tissue. Groups receiving low and medium fluid volume treatment had similar systemic haemodynamics. The high fluid volume group had significantly higher mean arterial pressure, cardiac index and subcutaneous tissue oxygenation. Tissue oxygen pressures in the jejunum and colon were comparable in all three groups. The three different fluid volume regimens tested did not affect tissue oxygen pressure in the jejunum and colon, suggesting efficient autoregulation of intestinal blood flow in healthy subjects undergoing uncomplicated abdominal surgery.

  10. Automatic blood pressure measuring system (M091)

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The Leg Volume Measuring System is used to measure leg calf girth changes that occur during exposure to lower body negative pressure as a result of pooling of blood and other fluids in the lower extremities.

  11. A 2D nonlinear multiring model for blood flow in large elastic arteries

    NASA Astrophysics Data System (ADS)

    Ghigo, Arthur R.; Fullana, Jose-Maria; Lagrée, Pierre-Yves

    2017-12-01

    In this paper, we propose a two-dimensional nonlinear ;multiring; model to compute blood flow in axisymmetric elastic arteries. This model is designed to overcome the numerical difficulties of three-dimensional fluid-structure interaction simulations of blood flow without using the over-simplifications necessary to obtain one-dimensional blood flow models. This multiring model is derived by integrating over concentric rings of fluid the simplified long-wave Navier-Stokes equations coupled to an elastic model of the arterial wall. The resulting system of balance laws provides a unified framework in which both the motion of the fluid and the displacement of the wall are dealt with simultaneously. The mathematical structure of the multiring model allows us to use a finite volume method that guarantees the conservation of mass and the positivity of the numerical solution and can deal with nonlinear flows and large deformations of the arterial wall. We show that the finite volume numerical solution of the multiring model provides at a reasonable computational cost an asymptotically valid description of blood flow velocity profiles and other averaged quantities (wall shear stress, flow rate, ...) in large elastic and quasi-rigid arteries. In particular, we validate the multiring model against well-known solutions such as the Womersley or the Poiseuille solutions as well as against steady boundary layer solutions in quasi-rigid constricted and expanded tubes.

  12. Measurement of rheologic property of blood by a falling-ball blood viscometer.

    PubMed

    Eguchi, Yoko; Karino, Takeshi

    2008-04-01

    The viscosity of blood obtained by using a rotational viscometer decreases with the time elapsed from the beginning of measurement until it reaches a constant value determined by the magnitude of shear rate. It is not possible to obtain an initial value of viscosity at time t = 0 that is considered to exhibit an intrinsic property of the fluid by this method. Therefore, we devised a new method by which one can obtain the viscosity of various fluids that are not affected by both the time elapsed from the beginning of measurement and the magnitude of shear rate by considering the balance of the forces acting on a solid spherical particle freely falling in a quiescent viscous fluid. By using the new method, we studied the rheologic behavior of corn syrups, carboxy-methyl cellulose, and human blood; and compared the results with those obtained with a cone-and-plate viscometer. It was found that in the case of corn syrups and washed red cell suspensions in which no red cell aggregate (rouleau) was formed, the viscosity obtained with the two different methods were almost the same. In contrast to this, in the case of the whole blood in which massive aggregates were formed, the viscosity obtained with a falling-ball viscometer was much larger than that obtained with a cone-plate viscometer.

  13. Evaluation of Intraosseous Fluid as an Alternative Biological Specimen in Postmortem Toxicology.

    PubMed

    Rodda, Luke N; Volk, Justin A; Moffat, Ellen; Williams, Chinyere M; Lynch, Kara L; Wu, Alan H B

    2018-04-01

    The postmortem redistribution phenomenon is an important factor in the interpretation of blood drug concentrations as a cause or factor in death. Intraosseous fluid (IOF) may serve as an alternative matrix for drug testing. Intraosseous fluid was collected from the left and right tibias and humerus of 29 decedents using the Arrow EZ-IO Intraosseous Vascular Access System. Standard autopsy specimens including blood were also collected at the same time during autopsy. Blood and IOF specimens were screened by immunoassay for opioids, fentanyl analogs, oxycodone, methadone, cocaine, methamphetamine, amphetamines, phencyclidine, tricyclic antidepressants, benzodiazepines and cannabinoids, using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Correlation between cardiac/central blood ELISA and IOF ELISA results was mostly 100% for drug targets. Further blood confirmation analysis was performed by gas chromatography mass spectrometry also showed comparable correlation to IOF screen results. There was no significant difference between the IOF sites or sides of the body. This novel study supports the use of IOF as an alternative postmortem specimen for toxicological investigations as a potentially less-compromised tissue in decomposed or traumatized bodies. Preliminary data is provided for the screening of common drugs of abuse in IOF that may show to be subject to alternative rates of postmortem redistribution than to that of other biological specimens in future studies that quantitate IOF drug concentrations.

  14. Self-induced stretch syncope of adolescence: a video-EEG documentation.

    PubMed

    Mazzuca, Michel; Thomas, Pierre

    2007-12-01

    We present the first video-EEG documentation, with ECG and EMG features, of stretch syncope of adolescence in a young, healthy 16-year-old boy. Stretch syncope of adolescence is a rarely reported, benign cause of fainting in young patients, which can be confused with epileptic seizures. In our patient, syncopes were self-induced to avoid school. Dynamic transcranial Doppler showed evidence of blood flow decrease in both posterior cerebral arteries mimicking effects of a Valsalva manoeuvre. Dynamic angiogram of the vertebral arteries was normal. Hypotheses concerning the physiopathology are discussed. [Published with video sequences].

  15. Periodontal disease level-butyric acid putatively contributes to the ageing blood: A proposed link between periodontal diseases and the ageing process.

    PubMed

    Cueno, Marni E; Seki, Keisuke; Ochiai, Kuniyasu; Imai, Kenichi

    2017-03-01

    Periodontal diseases are partly attributable to periodontopathic bacteria found in the host, whereas, butyric acid (BA) is a common secondary metabolite produced by periodontopathic bacterial pathogens. BA has been linked to oxidative stress induction while oxidative stress has long been associated with the ageing process. However, the possible link between BA-induced oxidative stress and the ageing process has never been elucidated. Here, we attempted to show the possible role of periodontal diseaselevel-BA (PDL-BA) in influencing the rat blood ageing process. We injected PDL-BA into the young rat gingiva and, after 24h, heart blood extraction was performed. Blood obtained from PDL-BA-treated young rats was compared to untreated young and middle-aged rats. We found that cytosolic, but not mitochondrial, heme was affected 24h post-injection. In addition, we observed that PDL-BA treatment altered blood NOX activation, NADPH-related oxidative stress components (H 2 O 2 and GR), calcium homeostasis, cell death signals (CASP3 and CASP1), and age-related markers (SIRT1 and mTOR) in young rats, with some components more closely mimicking levels found in middle-aged rats. In this regard, we propose that PDL-BA may play a role in contributing to the rat blood ageing process. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. A subserosal, pedunculated, multilocular uterine leiomyoma with ovarian tumor-like morphology and histological architecture of adenomatoid tumors: a case report and review of the literature.

    PubMed

    Yorita, Kenji; Tanaka, Yu; Hirano, Koki; Kai, Yuka; Arii, Kaoru; Nakatani, Kimiko; Ito, Satoshi; Imai, Toshiya; Fukunaga, Masaharu; Kuroda, Naoto

    2016-12-20

    Uterine leiomyomas are common uterine tumors, and typical cases of leiomyoma are easily diagnosed by imaging study. However, uterine leiomyomas are often altered by degenerative changes, which can cause difficulty and confusion in their clinical diagnosis. We describe the 17th reported case of a uterine leiomyoma clinically diagnosed as an ovarian tumor; however, the present case shows the most detailed radiological evaluation, including contrast-enhanced magnetic resonance imaging. We first show that a uterine leiomyoma can histologically mimic an adenomatoid tumor. A 47-year-old premenopausal, nulliparous Japanese woman with a history of type 2 diabetes mellitus, hypertension, and hyperlipidemia had lower abdominal pain. Ultrasonography confirmed a 6-cm mass in the right-sided space of the pelvic cavity. Magnetic resonance imaging evaluation showed that a multilocular mass was present near the uterus, and a mucinous ovarian tumor was considered. Emergency surgery due to acute abdomen was performed under the diagnosis of pedicle torsion of the ovarian tumor. During surgery, a pedunculated uterine mass without stalk torsion was seen. The mass grossly contained serous and hemorrhagic fluids in the cavities, and pathology examination confirmed that the mass was a leiomyoma with hydropic and cystic degeneration. Anastomosing thin cord-like arrangements of the leiomyoma cells mimicked the architecture of adenomatoid tumors. The tumor cells were positive for the microphthalmia transcription factor but negative for other melanoma markers. Three days postoperatively, she was discharged without sequelae. Marked intratumoral deposition of fluids may induce the multilocular morphology of a tumor, and the cellular arrangement of the tumor cells with hydropic degeneration mimicked an adenomatoid tumor in this case. Clinicians need to be aware that a subserosal leiomyoma with cystic and hydropic degeneration can mimic an ovarian tumor, and pathologists should be aware that such leiomyomas can mimic adenomatoid tumors. Additionally, perivascular epithelioid cell tumors should not be diagnosed only based on its immunoreactivity for the microphthalmia transcription factor.

  17. Blood Type Biochemistry and Human Disease

    PubMed Central

    Ewald, D Rose; Sumner, Susan CJ

    2016-01-01

    Associations between blood type and disease have been studied since the early 1900s when researchers determined that antibodies and antigens are inherited. In the 1950s, the chemical identification of the carbohydrate structure of surface antigens led to the understanding of biosynthetic pathways. The blood type is defined by oligosaccharide structures, which are specific to the antigens, thus, blood group antigens are secondary gene products, while the primary gene products are various glycosyltransferase enzymes that attach the sugar molecules to the oligosaccharide chain. Blood group antigens are found on red blood cells, platelets, leukocytes, plasma proteins, certain tissues, and various cell surface enzymes, and also exist in soluble form in body secretions such as breast milk, seminal fluid, saliva, sweat, gastric secretions, urine, and amniotic fluid. Recent advances in technology, biochemistry, and genetics have clarified the functional classifications of human blood group antigens, the structure of the A, B, H, and Lewis determinants and the enzymes that produce them, and the association of blood group antigens with disease risks. Further research to identify differences in the biochemical composition of blood group antigens, and the relationship to risks for disease, can be important for the identification of targets for the development of nutritional intervention strategies, or the identification of druggable targets. PMID:27599872

  18. Skeletal muscle contractions uncoupled from gravitational loading directly increase cortical bone blood flow rates in vivo.

    PubMed

    Caulkins, Carrie; Ebramzadeh, Edward; Winet, Howard

    2009-05-01

    The direct and indirect effects of muscle contraction on bone microcirculation and fluid flow are neither well documented nor explained. However, skeletal muscle contractions may affect the acquisition and maintenance of bone via stimulation of bone circulatory and interstitial fluid flow parameters. The purposes of this study were to assess the effects of transcutaneous electrical neuromuscular stimulation (TENS)-induced muscle contractions on cortical bone blood flow and bone mineral content, and to demonstrate that alterations in blood flow could occur independently of mechanical loading and systemic circulatory mechanisms. Bone chamber implants were used in a rabbit model to observe real-time blood flow rates and TENS-induced muscle contractions. Video recording of fluorescent microspheres injected into the blood circulation was used to calculate changes in cortical blood flow rates. TENS-induced repetitive muscle contractions uncoupled from mechanical loading instantaneously increased cortical microcirculatory flow, directly increased bone blood flow rates by 130%, and significantly increased bone mineral content over 7 weeks. Heart rates and blood pressure did not significantly increase due to TENS treatment. Our findings suggest that muscle contraction therapies have potential clinical applications for improving blood flow to cortical bone in the appendicular skeleton. Copyright 2008 Orthopaedic Research Society

  19. Roughness influence on human blood drop spreading and splashing

    NASA Astrophysics Data System (ADS)

    Smith, Fiona; Buntsma, Naomi; Brutin, David

    2017-11-01

    The impact behaviour of complex fluid droplets is a topic that has been extensively studied but with much debate. The Bloodstain Pattern Analysis (BPA) community is encountering this scientific problem with daily practical cases since they use bloodstains as evidence in crime scene reconstruction. We aim to provide fundamental explanations in the study of blood drip stains by investigating the influence of surface roughness and wettability on the splashing limit of droplets of blood, a non-Newtonian colloidal fluid. Droplets of blood impacting perpendicularly different surfaces at different velocities were recorded. The recordings were analysed as well as the surfaces characteristics in order to find an empirical solution since we found that roughness plays a major role in the threshold of the splashing/non-splashing behaviour of blood compared to the wettability. Moreover it appears that roughness alters the deformation of the drip stains. These observations are key in characterising features of drip stains with the impacting conditions, which would answer some forensic issues.

  20. An Integrated Platform for Isolation, Processing, and Mass Spectrometry-based Proteomic Profiling of Rare Cells in Whole Blood*

    PubMed Central

    Li, Siyang; Plouffe, Brian D.; Belov, Arseniy M.; Ray, Somak; Wang, Xianzhe; Murthy, Shashi K.; Karger, Barry L.; Ivanov, Alexander R.

    2015-01-01

    Isolation and molecular characterization of rare cells (e.g. circulating tumor and stem cells) within biological fluids and tissues has significant potential in clinical diagnostics and personalized medicine. The present work describes an integrated platform of sample procurement, preparation, and analysis for deep proteomic profiling of rare cells in blood. Microfluidic magnetophoretic isolation of target cells spiked into 1 ml of blood at the level of 1000–2000 cells/ml, followed by focused acoustics-assisted sample preparation has been coupled with one-dimensional PLOT-LC-MS methodology. The resulting zeptomole detection sensitivity enabled identification of ∼4000 proteins with injection of the equivalent of only 100–200 cells per analysis. The characterization of rare cells in limited volumes of physiological fluids is shown by the isolation and quantitative proteomic profiling of first MCF-7 cells spiked into whole blood as a model system and then two CD133+ endothelial progenitor and hematopoietic cells in whole blood from volunteers. PMID:25755294