21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
21 CFR 864.9900 - Cord blood processing system and storage container.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Cord blood processing system and storage container... Manufacture Human Cells, Tissues, and Cellular and Tissue-Based Products (HCT/Ps) § 864.9900 Cord blood processing system and storage container. (a) Identification. A cord blood processing system and storage...
Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz
2012-01-01
Background The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Materials and methods Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. Results The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. Discussion These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement. PMID:22044958
Jurado, Marisa; Algora, Manuel; Garcia-Sanchez, Félix; Vico, Santiago; Rodriguez, Eva; Perez, Sonia; Barbolla, Luz
2012-01-01
The Community Transfusion Centre in Madrid currently processes whole blood using a conventional procedure (Compomat, Fresenius) followed by automated processing of buffy coats with the OrbiSac system (CaridianBCT). The Atreus 3C system (CaridianBCT) automates the production of red blood cells, plasma and an interim platelet unit from a whole blood unit. Interim platelet unit are pooled to produce a transfusable platelet unit. In this study the Atreus 3C system was evaluated and compared to the routine method with regards to product quality and operational value. Over a 5-week period 810 whole blood units were processed using the Atreus 3C system. The attributes of the automated process were compared to those of the routine method by assessing productivity, space, equipment and staffing requirements. The data obtained were evaluated in order to estimate the impact of implementing the Atreus 3C system in the routine setting of the blood centre. Yield and in vitro quality of the final blood components processed with the two systems were evaluated and compared. The Atreus 3C system enabled higher throughput while requiring less space and employee time by decreasing the amount of equipment and processing time per unit of whole blood processed. Whole blood units processed on the Atreus 3C system gave a higher platelet yield, a similar amount of red blood cells and a smaller volume of plasma. These results support the conclusion that the Atreus 3C system produces blood components meeting quality requirements while providing a high operational efficiency. Implementation of the Atreus 3C system could result in a large organisational improvement.
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2012 CFR
2012-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2014 CFR
2014-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2010 CFR
2010-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2013 CFR
2013-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Processing system for frozen blood. 864.9145...
21 CFR 864.9145 - Processing system for frozen blood.
Code of Federal Regulations, 2011 CFR
2011-04-01
... system for frozen blood is a device used to glycerolize red blood cells prior to freezing to minimize... thawing of red blood cells and to deglycerolize and wash thawed cells for subsequent reinfusion. (b... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Processing system for frozen blood. 864.9145...
Yoon, Chiyul; Noh, Seungwoo; Lee, Jung Chan; Ko, Sung Ho; Ahn, Wonsik; Kim, Hee Chan
2014-03-01
The continuous autotransfusion system has been widely used in surgical operations. It is known that if oil is added to blood, and this mixture is then processed by an autotransfusion device, the added oil is removed and reinfusion of fat is prevented by the device. However, there is no detailed report on the influence of the particular washing program selected on the levels of blood components including blood fat after continuous autotransfusion using such a system. Fresh bovine blood samples were processed by a commercial continuous autotransfusion device using the "emergency," "quality," and "high-quality" programs, applied in random order. Complete blood count (CBC) and serum chemistry were analyzed to determine how the blood processing performance of the device changes with the washing program applied. There was no significant difference in the CBC results obtained with the three washing programs. Although all of the blood lipids in the processed blood were decreased compared to those in the blood before processing, the levels of triglyceride, phospholipid, and total cholesterol after processing via the emergency program were significantly higher than those present after processing via the quality and high-quality programs. Although the continuous autotransfusion device provided consistent hematocrit quality, the levels of some blood lipid components showed significant differences among the washing programs.
Gifford, Sean C; Strachan, Briony C; Xia, Hui; Vörös, Eszter; Torabian, Kian; Tomasino, Taylor A; Griffin, Gary D; Lichtiger, Benjamin; Aung, Fleur M; Shevkoplyas, Sergey S
2018-01-01
The use of centrifugation-based approaches for processing donated blood into components is routine in the industrialized world, as disparate storage conditions require the rapid separation of 'whole blood' into distinct red blood cell (RBC), platelet, and plasma products. However, the logistical complications and potential cellular damage associated with centrifugation/apheresis manufacturing of blood products are well documented. The objective of this study was to evaluate a proof-of-concept system for whole blood processing, which does not employ electromechanical parts, is easily portable, and can be operated immediately after donation with minimal human labor. In a split-unit study (n = 6), full (~500mL) units of freshly-donated whole blood were divided, with one half processed by conventional centrifugation techniques and the other with the new blood separation system. Each of these processes took 2-3 hours to complete and were performed in parallel. Blood products generated by the two approaches were compared using an extensive panel of cellular and plasma quality metrics. Comparison of nearly all RBC parameters showed no significant differences between the two approaches, although the portable system generated RBC units with a slight but statistically significant improvement in 2,3-diphosphoglyceric acid concentration (p < 0.05). More notably, several markers of platelet damage were significantly and meaningfully higher in products generated with conventional centrifugation: the increase in platelet activation (assessed via P-selectin expression in platelets before and after blood processing) was nearly 4-fold higher for platelet units produced via centrifugation, and the release of pro-inflammatory mediators (soluble CD40-ligand, thromboxane B2) was significantly higher for centrifuged platelets as well (p < 0.01). This study demonstrated that a simple, passive system for separating donated blood into components may be a viable alternative to centrifugation-particularly for applications in remote or resource-limited settings, or for patients requiring highly functional platelet product.
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Source Plasma § 640.68 Processing. (a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for...
Process mining is an underutilized clinical research tool in transfusion medicine.
Quinn, Jason G; Conrad, David M; Cheng, Calvino K
2017-03-01
To understand inventory performance, transfusion services commonly use key performance indicators (KPIs) as summary descriptors of inventory efficiency that are graphed, trended, and used to benchmark institutions. Here, we summarize current limitations in KPI-based evaluation of blood bank inventory efficiency and propose process mining as an ideal methodology for application to inventory management research to improve inventory flows and performance. The transit of a blood product from inventory receipt to final disposition is complex and relates to many internal and external influences, and KPIs may be inadequate to fully understand the complexity of the blood supply chain and how units interact with its processes. Process mining lends itself well to analysis of blood bank inventories, and modern laboratory information systems can track nearly all of the complex processes that occur in the blood bank. Process mining is an analytical tool already used in other industries and can be applied to blood bank inventory management and research through laboratory information systems data using commercial applications. Although the current understanding of real blood bank inventories is value-centric through KPIs, it potentially can be understood from a process-centric lens using process mining. © 2017 AABB.
Wong, Kit Fai
2011-01-01
Virtual blood bank is the computer-controlled, electronically linked information management system that allows online ordering and real-time, remote delivery of blood for transfusion. It connects the site of testing to the point of care at a remote site in a real-time fashion with networked computers thus maintaining the integrity of immunohematology test results. It has taken the advantages of information and communication technologies to ensure the accuracy of patient, specimen and blood component identification and to enhance personnel traceability and system security. The built-in logics and process constraints in the design of the virtual blood bank can guide the selection of appropriate blood and minimize transfusion risk. The quality of blood inventory is ascertained and monitored, and an audit trail for critical procedures in the transfusion process is provided by the paperless system. Thus, the virtual blood bank can help ensure that the right patient receives the right amount of the right blood component at the right time. PMID:21383930
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Plasma § 640.34 Processing. (a) Plasma. Plasma shall be... collecting, processing, and storage system unless the product is to be stored as Liquid Plasma. (b) Fresh Frozen Plasma. Fresh frozen plasma shall be prepared from blood collected by a single uninterrupted...
Kurasawa, Shintaro; Koyama, Shouhei; Ishizawa, Hiroaki; Fujimoto, Keisaku; Chino, Shun
2017-11-23
This paper describes and verifies a non-invasive blood glucose measurement method using a fiber Bragg grating (FBG) sensor system. The FBG sensor is installed on the radial artery, and the strain (pulse wave) that is propagated from the heartbeat is measured. The measured pulse wave signal was used as a collection of feature vectors for multivariate analysis aiming to determine the blood glucose level. The time axis of the pulse wave signal was normalized by two signal processing methods: the shortest-time-cut process and 1-s-normalization process. The measurement accuracy of the calculated blood glucose level was compared with the accuracy of these signal processing methods. It was impossible to calculate a blood glucose level exceeding 200 mg/dL in the calibration curve that was constructed by the shortest-time-cut process. In the 1-s-normalization process, the measurement accuracy of the blood glucose level was improved, and a blood glucose level exceeding 200 mg/dL could be calculated. By verifying the loading vector of each calibration curve to calculate the blood glucose level with a high measurement accuracy, we found the gradient of the peak of the pulse wave at the acceleration plethysmogram greatly affected.
Davis, Rodeina; Geiger, Bradley; Gutierrez, Alfonso; Heaser, Julie; Veeramani, Dharmaraj
2009-07-01
Radio frequency identification (RFID) can be a key enabler for enhancing productivity and safety of the blood product supply chain. This article describes a systematic approach developed by the RFID Blood Consortium for a comprehensive feasibility and impact assessment of RFID application in blood centre operations. Our comprehensive assessment approach incorporates process-orientated and technological perspectives as well as impact analysis. Assessment of RFID-enabled process redesign is based on generic core processes derived from the three participating blood centres. The technological assessment includes RFID tag readability and performance evaluation, testing of temperature and biological effects of RF energy on blood products, and RFID system architecture design and standards. The scope of this article is limited to blood centre processes (from donation to manufacturing/distribution) for selected mainstream blood products (red blood cells and platelets). Radio frequency identification can help overcome a number of common challenges and process inefficiencies associated with identification and tracking of blood products. High frequency-based RFID technology performs adequately and safely for red blood cell and platelet products. Productivity and quality improvements in RFID-enabled blood centre processes can recoup investment cost in a 4-year payback period. Radio frequency identification application has significant process-orientated and technological implications. It is feasible and economically justifiable to incorporate RFID into blood centre processes.
2007-02-01
The Food and Drug Administration (FDA) is classifying a cord blood processing system and storage container into class II (special controls). The special control that will apply to this device is the guidance document entitled "Class II Special Controls Guidance Document: Cord Blood Processing System and Storage Container." FDA is classifying this device into class II (special controls) in order to provide a reasonable assurance of safety and effectiveness of this device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.
Machine Learning Based Single-Frame Super-Resolution Processing for Lensless Blood Cell Counting
Huang, Xiwei; Jiang, Yu; Liu, Xu; Xu, Hang; Han, Zhi; Rong, Hailong; Yang, Haiping; Yan, Mei; Yu, Hao
2016-01-01
A lensless blood cell counting system integrating microfluidic channel and a complementary metal oxide semiconductor (CMOS) image sensor is a promising technique to miniaturize the conventional optical lens based imaging system for point-of-care testing (POCT). However, such a system has limited resolution, making it imperative to improve resolution from the system-level using super-resolution (SR) processing. Yet, how to improve resolution towards better cell detection and recognition with low cost of processing resources and without degrading system throughput is still a challenge. In this article, two machine learning based single-frame SR processing types are proposed and compared for lensless blood cell counting, namely the Extreme Learning Machine based SR (ELMSR) and Convolutional Neural Network based SR (CNNSR). Moreover, lensless blood cell counting prototypes using commercial CMOS image sensors and custom designed backside-illuminated CMOS image sensors are demonstrated with ELMSR and CNNSR. When one captured low-resolution lensless cell image is input, an improved high-resolution cell image will be output. The experimental results show that the cell resolution is improved by 4×, and CNNSR has 9.5% improvement over the ELMSR on resolution enhancing performance. The cell counting results also match well with a commercial flow cytometer. Such ELMSR and CNNSR therefore have the potential for efficient resolution improvement in lensless blood cell counting systems towards POCT applications. PMID:27827837
Development of blood vessel searching system for HMS
NASA Astrophysics Data System (ADS)
Kandani, Hirofumi; Uenoya, Toshiyuki; Uetsuji, Yasutomo; Nakamachi, Eiji
2008-08-01
In this study, we develop a new 3D miniature blood vessel searching system by using near-infrared LED light, a CMOS camera module with an image processing unit for a health monitoring system (HMS), a drug delivery system (DDS) which requires very high performance for automatic micro blood volume extraction and automatic blood examination. Our objective is to fabricate a highly reliable micro detection system by utilizing image capturing, image processing, and micro blood extraction devices. For the searching system to determine 3D blood vessel location, we employ the stereo method. The stereo method is a common photogrammetric method. It employs the optical path principle to detect 3D location of the disparity between two cameras. The principle for blood vessel visualization is derived from the ratio of hemoglobin's absorption of the near-infrared LED light. To get a high quality blood vessel image, we adopted an LED, with peak a wavelength of 940nm. The LED is set on the dorsal side of the finger and it irradiates the human finger. A blood vessel image is captured by a CMOS camera module, which is set below the palmer side of the finger. 2D blood vessel location can be detected by the luminance distribution of a one pixel line. To examine the accuracy of our detecting system, we carried out experiments using finger phantoms with blood vessel diameters of 0.5, 0.75, 1.0mm, at the depths of 0.5 ~ 2.0 mm from the phantom's surface. The experimental results of the estimated depth obtained by our detecting system shows good agreements with the given depths, and the viability of this system is confirmed.
Lotens, A; Najdovski, T; Cellier, N; Ernotte, B; Lambermont, M; Rapaille, A
2014-10-01
TACSI whole blood system is designed to combine primary and secondary processing of six whole blood bags into plasma units, buffy coat and red blood cell concentrates. The aim of this study was to investigate the specifications and in vitro storage parameters of blood components compared with standard centrifugation and separation processing. Whole blood bags, collected in CRC kits, were treated on a TACSI whole blood system. They were compared with whole blood bags collected in Composelect kits. In addition to routine quality control analyses, conservation studies were performed on red blood cell concentrates for 42 days and on plasma for 6 months. Platelets pools with five buffy coats were also created, and cellular contamination was evaluated. Red blood cell concentrates produced from TACSI whole blood met European quality requirements. For white blood cell count, one individual result exceeded 1 × 10(6) cells/unit. All plasma units fell within specifications for residual cellular contamination and storage parameters. The performances of the TACSI whole blood system allow for the preparation of low volume buffy coats with a recovery of 90% of whole blood platelets. Haemoglobin losses in TACSI BC are smaller, but this did not result in higher haemoglobin content of red cells. These BC are suitable for the production of platelet concentrates. From these in vitro data, red blood cell concentrates produced using TACSI whole blood are suitable for clinical use with a quality at least equivalent to the control group. © 2014 International Society of Blood Transfusion.
ERIC Educational Resources Information Center
Hopper, Mari K.; Maurer, Luke W.
2013-01-01
Digestive physiology laboratory exercises often explore the regulation of enzyme action rather than systems physiology. This laboratory exercise provides a systems approach to digestive and regulatory processes through the exploration of postprandial blood glucose levels. In the present exercise, students enrolled in an undergraduate animal…
A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit time.
Buxi, Dilpreet; Redouté, Jean-Michel; Yuce, Mehmet Rasit
2015-03-01
Blood pressure monitoring based on pulse transit or arrival time has been the focus of much research in order to design ambulatory blood pressure monitors. The accuracy of these monitors is limited by several challenges, such as acquisition and processing of physiological signals as well as changes in vascular tone and the pre-ejection period. In this work, a literature survey covering recent developments is presented in order to identify gaps in the literature. The findings of the literature are classified according to three aspects. These are the calibration of pulse transit/arrival times to blood pressure, acquisition and processing of physiological signals and finally, the design of fully integrated blood pressure measurement systems. Alternative technologies as well as locations for the measurement of the pulse wave signal should be investigated in order to improve the accuracy during calibration. Furthermore, the integration and validation of monitoring systems needs to be improved in current ambulatory blood pressure monitors.
An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System
George, Paul E; Vidal, Julio; Garcia, Patricia J
2016-01-01
Background Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Methods Every Peruvian blood bank was evaluated by MINSA from 2007–2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Results Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Conclusion Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product. PMID:27761524
An Analysis of and Recommendations for the Peruvian Blood Collection and Transfusion System.
George, Paul E; Vidal, Julio; Garcia, Patricia J
2016-05-01
Peru experienced a crisis in its blood collection and supply system in the mid-2000s, as contaminated blood led to several transfusion-transmitted infections (TTI), occurring in the backdrop of extremely low voluntary donation rates and a national blood supply shortage. Thus, the Peruvian Ministry of Health (MINSA) implemented a national investigation on the safety and quality of the Peruvian blood collection/transfusion network. Every Peruvian blood bank was evaluated by MINSA from 2007-2008. These evaluations consisted of an update of the national registry of blood banks and visits to each blood bank from MINSA oversight teams. Information was collected on the condition of the blood bank personnel, equipment, supplies, and practices. Further, previously-collected blood at each blood bank was randomly selected and screened for TTI-causing pathogens. Uncovered in this investigation was a fragmented, under-equipped, and poorly-staffed blood collection and transfusion network, consisting of 241 independent blood banks and resulting in suboptimal allocation of resources. Further, blood with evidence of TTI-causing pathogens (including Hepatitis B, Hepatitis C, and syphilis) and set for transfusion was discovered at three separate blood banks as part of the random screening process. Using the successful reorganizations of national blood supply systems in other Latin American countries as examples, Peru would be well-served to form large, high-volume, regional blood collection and transfusion centers, responsible for blood collection and screening for the entire country. The small, separate blood banks would then be transformed into a network of blood transfusion centers, not responsible for blood collection. This reorganization would allow Peru to better utilize its resources, standardize the blood collection and transfusion process, and increase voluntary donation, resulting in a safer, more abundant national blood product.
Mendes, Romeu; Themudo Barata, J L
2008-01-01
High blood pressure is a major risk factor of cardiovascular diseases and has a high prevalence in the older individuals becoming in a risk factor associated with high cardiovascular mortality and morbidity among these population. This study has the objective to analyze the changes in the cardiovascular system inherent to the aging process, that provoke the increase of blood pressure levels with the advance of age and that can origin hypertension. With the aging process, changes in the anatomy and cardiovascular physiology occur, even in the absence of illness. High blood pressure is characterized as a systemic condition that involves the presence of structural changes of the arteries and the myocardium, associated to an endotelial and baroreceptors dysfunction.
Application of Six Sigma/CAP methodology: controlling blood-product utilization and costs.
Neri, Robert A; Mason, Cindy E; Demko, Lisa A
2008-01-01
Blood-product components are a limited commodity whose cost is rising. Many patients benefit from their use, but patients who receive transfusions face an unnecessary increased risk for developing infections; fatal, febrile, or allergic reactions; and circulatory overload. To improve patient care, safety, and resource stewardship, transfusion practices must be evaluated for appropriateness (Wilson et al. 2002). A multihospital health system undertook a rigorous study of blood-product utilization patterns and management processes to address cost-control problems in the organization. The system leveraged two process improvement tools widely implemented outside of the healthcare industry: (1) Six Sigma methodology to identify blood-utilization drivers and to standardize transfusion practice, and (2) change acceleration process model to drive effective change. The initiative resulted in a decreased rate of inappropriate transfusions of packed red blood cell from 16 percent to less than 5 percent, improved clinician use of a blood-component order form, establishment of internal benchmarks, enhanced laboratory-to-clinician communication, and better blood-product expense control. The project further demonstrated how out-of-industry tools and methodologies can be adopted, adapted, and systematically applied to generate positive change (Black and Revere 2006).
2015-01-01
Background and Aims: The mortality rate from vascular diseases is one of the highest. The use of Intravenous Laser Blood Irradiation (ILBI) within the last 30 years has demonstrated high efficacy in the treatment of vascular, cardiac and other systemic diseases. Rationale: Laser energy at 630-640 nanometers is arguably the most effective for irradiation of blood and the vascular wall. Photons at this wavelength are absorbed by oxygen, improve microcirculation, can change the viscosity of the blood and affect vascular endothelium. Conclusions: In summary, more than 25 years of experience of using laser energy at 630-640 nm has shown that this waveband directly influences the parameters of all cells in the blood, blood plasma, the coagulation process and all the structural components of the vascular wall. Additionally, ILBI directly or indirectly affects the cells of the immune system, hormones, and exchange processes in an organism, thereby not only improving the function of the vascular system, but also the other systems of an organism. It can finally lead to lower the incidence and number of vascular diseases, and indirectly to the reduction of the number of diseases in other organs and even systemically, thus helping to prolong the lifespan. PMID:25941421
In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System.
Alberts, Melissa; Groom, Robert C; Walczak, Richard; Kramer, Robert; Karpiel, Adrienne; Dieter, Jeanette; Sheth, Lisa; Greene, Nathaniel H; Jooste, Edmund H
2017-06-01
Use of autotransfusion systems to collect, wash, and concentrate shed blood during surgical procedures is a widely used method for reducing postoperative anemia and the need for blood transfusions. The aim of this study was to evaluate the CATSmart Continuous Autotransfusion System wash program performance with small (200 or 700 mL) and large volumes (1,000 mL) of shed blood and to determine non-inferiority of the CATSmart to the C.A.T.S plus system. Human whole blood was collected in citrate phosphate dextrose, diluted, and divided into two aliquots to be processed as a pair using the C.A.T.S plus and CATSmart systems with their corresponding wash programs: low-volume, high quality/smart, or emergency wash. Final packed red cell product was analyzed for red blood cell (RBC), white blood cell, and platelet counts; hemoglobin; hemolysis; RBC recovery rates; and elimination of albumin, total protein, and potassium. The mean hematocrit (HCT) after processing with CATSmart and C.A.T.S plus systems were 59.63% and 57.71%, respectively. The calculated overall RBC recovery rates on the CATSmart and C.A.T.S plus systems were 85.41% and 84.99%, respectively. Elimination of albumin (97.5%, 98.0%), total proteins (97.1%, 97.5%), and potassium (92.1%, 91.9%) were also calculated for the CATSmart and C.A.T.S plus systems. The CATSmart and C.A.T.S plus systems both provided a high-quality product in terms of HCT, protein elimination, and hemolysis rates across the range of tested shed blood volumes and all wash programs. The study was able to confirm the CATSmart is non-inferior to the C.A.T.S plus system.
In Vitro Evaluation of the Fresenius Kabi CATSmart Autotransfusion System
Alberts, Melissa; Groom, Robert C.; Walczak, Richard; Kramer, Robert; Karpiel, Adrienne; Dieter, Jeanette; Sheth, Lisa; Greene, Nathaniel H.; Jooste, Edmund H.
2017-01-01
Abstract: Use of autotransfusion systems to collect, wash, and concentrate shed blood during surgical procedures is a widely used method for reducing postoperative anemia and the need for blood transfusions. The aim of this study was to evaluate the CATSmart Continuous Autotransfusion System wash program performance with small (200 or 700 mL) and large volumes (1,000 mL) of shed blood and to determine non-inferiority of the CATSmart to the C.A.T.Splus system. Human whole blood was collected in citrate phosphate dextrose, diluted, and divided into two aliquots to be processed as a pair using the C.A.T.Splus and CATSmart systems with their corresponding wash programs: low-volume, high quality/smart, or emergency wash. Final packed red cell product was analyzed for red blood cell (RBC), white blood cell, and platelet counts; hemoglobin; hemolysis; RBC recovery rates; and elimination of albumin, total protein, and potassium. The mean hematocrit (HCT) after processing with CATSmart and C.A.T.Splus systems were 59.63% and 57.71%, respectively. The calculated overall RBC recovery rates on the CATSmart and C.A.T.Splus systems were 85.41% and 84.99%, respectively. Elimination of albumin (97.5%, 98.0%), total proteins (97.1%, 97.5%), and potassium (92.1%, 91.9%) were also calculated for the CATSmart and C.A.T.Splus systems. The CATSmart and C.A.T.Splus systems both provided a high-quality product in terms of HCT, protein elimination, and hemolysis rates across the range of tested shed blood volumes and all wash programs. The study was able to confirm the CATSmart is non-inferior to the C.A.T.Splus system. PMID:28638159
Vogeser, Michael; Spöhrer, Ute
2006-01-01
Liquid chromatography tandem-mass spectrometry (LC-MS/MS) is an efficient technology for routine determination of immunosuppressants in whole blood; however, time-consuming manual sample preparation remains a significant limitation of this technique. Using a commercially available robotic pipetting system (Tecan Freedom EVO), we developed an automated sample-preparation protocol for quantification of tacrolimus in whole blood by LC-MS/MS. Barcode reading, sample resuspension, transfer of whole blood aliquots into a deep-well plate, addition of internal standard solution, mixing, and protein precipitation by addition of an organic solvent is performed by the robotic system. After centrifugation of the plate, the deproteinized supernatants are submitted to on-line solid phase extraction, using column switching prior to LC-MS/MS analysis. The only manual actions within the entire process are decapping of the tubes, and transfer of the deep-well plate from the robotic system to a centrifuge and finally to the HPLC autosampler. Whole blood pools were used to assess the reproducibility of the entire analytical system for measuring tacrolimus concentrations. A total coefficient of variation of 1.7% was found for the entire automated analytical process (n=40; mean tacrolimus concentration, 5.3 microg/L). Close agreement between tacrolimus results obtained after manual and automated sample preparation was observed. The analytical system described here, comprising automated protein precipitation, on-line solid phase extraction and LC-MS/MS analysis, is convenient and precise, and minimizes hands-on time and the risk of mistakes in the quantification of whole blood immunosuppressant concentrations compared to conventional methods.
Blood monitoring systems and methods thereof
NASA Technical Reports Server (NTRS)
Zander, Dennis (Inventor); Mir, Jose (Inventor)
2012-01-01
A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.
Hehmke, Bernd; Berg, Sabine; Salzsieder, Eckhard
2017-05-01
Continuous standardized verification of the accuracy of blood glucose meter systems for self-monitoring after their introduction into the market is an important clinically tool to assure reliable performance of subsequently released lots of strips. Moreover, such published verification studies permit comparison of different blood glucose monitoring systems and, thus, are increasingly involved in the process of evidence-based purchase decision making.
One System for Blood Program Information Management
Gero, Michael G.; Klickstein, Judith S.; Hurst, Timm M.
1980-01-01
A system which integrates the diverse functions of a Blood Program within one structure is being assembled at the American National Red Cross Blood Services, Northeast Region. When finished, it will provide technical support for collection scheduling, donor recruitment, recordkeeping, laboratory processing, inventory management, HLA typing and matching, distribution, and administration within the Program. By linking these applications, a reporting structure useful to top management will be provided.
Nitric oxide transport in blood: a third gas in the respiratory cycle.
Doctor, Allan; Stamler, Jonathan S
2011-01-01
The trapping, processing, and delivery of nitric oxide (NO) bioactivity by red blood cells (RBCs) have emerged as a conserved mechanism through which regional blood flow is linked to biochemical cues of perfusion sufficiency. We present here an expanded paradigm for the human respiratory cycle based on the coordinated transport of three gases: NO, O₂, and CO₂. By linking O₂ and NO flux, RBCs couple vessel caliber (and thus blood flow) to O₂ availability in the lung and to O₂ need in the periphery. The elements required for regulated O₂-based signal transduction via controlled NO processing within RBCs are presented herein, including S-nitrosothiol (SNO) synthesis by hemoglobin and O₂-regulated delivery of NO bioactivity (capture, activation, and delivery of NO groups at sites remote from NO synthesis by NO synthase). The role of NO transport in the respiratory cycle at molecular, microcirculatory, and system levels is reviewed. We elucidate the mechanism through which regulated NO transport in blood supports O₂ homeostasis, not only through adaptive regulation of regional systemic blood flow but also by optimizing ventilation-perfusion matching in the lung. Furthermore, we discuss the role of NO transport in the central control of breathing and in baroreceptor control of blood pressure, which subserve O₂ supply to tissue. Additionally, malfunctions of this transport and signaling system that are implicated in a wide array of human pathophysiologies are described. Understanding the (dys)function of NO processing in blood is a prerequisite for the development of novel therapies that target the vasoactive capacities of RBCs. © 2011 American Physiological Society.
Comparison of human umbilical cord blood processing with or without hydroxyethyl starch.
Souri, Milad; Nikougoftar Zarif, Mahin; Rasouli, Mahboobeh; Golzadeh, Khadijeh; Nakhlestani Hagh, Mozhdeh; Ezzati, Nasim; Atarodi, Kamran
2017-11-01
Umbilical cord blood (UCB) processing with hydroxyethyl starch (HES) is the most common protocol in the cord blood banks. The quality of UCB volume reduction was guaranteed by minimum manipulation of cord blood samples in the closed system. This study aimed to analyze and compare cell recovery and viability of UCB processed using the Sepax automated system in the presence and absence of HES. Thirty UCB bags with a total nucleated cell (TNC) count of more than 2.5 × 10 9 were divided in two bags with equal volume. HES solution was added to one bag and another was intact. Both bags were processed with the Sepax. To determine cell recovery, viability, and potential of colony-forming cells (CFCs), preprocessing, postprocessing, and thawing samples were analyzed. The mean TNC recovery after processing and after thaw was significantly better with the HES method (p < 0.01 for the postprocessing step and p < 0.05 for the postthaw step). There were no significant differences to mononucleated cells (MNCs) and CD34+ cell recovery between the two methods after processing and after thaw. TNC and MNC viability was significantly higher without HES after processing and after thaw (p < 0.01). The results of the CFC assay were similar for both methods after processing and after thaw. These results showed that processing of UCB using the Sepax system with the without-HES protocol due to the lower manipulation of samples could be used as an eligible protocol to reduce the volume of UCB. © 2017 AABB.
Automated drug identification system
NASA Technical Reports Server (NTRS)
Campen, C. F., Jr.
1974-01-01
System speeds up analysis of blood and urine and is capable of identifying 100 commonly abused drugs. System includes computer that controls entire analytical process by ordering various steps in specific sequences. Computer processes data output and has readout of identified drugs.
Laser cutting eliminates nucleic acid cross-contamination in dried-blood-spot processing.
Murphy, Sean C; Daza, Glenda; Chang, Ming; Coombs, Robert
2012-12-01
Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing.
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
An electronic circuit for processing arterial blood pressure waveform signals is described. The circuit detects blood pressure as the heart pumps blood through the aortic valve and the pressure distribution caused by aortic valve closure. From these measurements, timing signals for use in measuring the left ventricular ejection time is determined, and signals are provided for computer monitoring of the cardiovascular system. Illustrations are given of the circuit and pressure waveforms.
Prinyakupt, Jaroonrut; Pluempitiwiriyawej, Charnchai
2015-06-30
Blood smear microscopic images are routinely investigated by haematologists to diagnose most blood diseases. However, the task is quite tedious and time consuming. An automatic detection and classification of white blood cells within such images can accelerate the process tremendously. In this paper we propose a system to locate white blood cells within microscopic blood smear images, segment them into nucleus and cytoplasm regions, extract suitable features and finally, classify them into five types: basophil, eosinophil, neutrophil, lymphocyte and monocyte. Two sets of blood smear images were used in this study's experiments. Dataset 1, collected from Rangsit University, were normal peripheral blood slides under light microscope with 100× magnification; 555 images with 601 white blood cells were captured by a Nikon DS-Fi2 high-definition color camera and saved in JPG format of size 960 × 1,280 pixels at 15 pixels per 1 μm resolution. In dataset 2, 477 cropped white blood cell images were downloaded from CellaVision.com. They are in JPG format of size 360 × 363 pixels. The resolution is estimated to be 10 pixels per 1 μm. The proposed system comprises a pre-processing step, nucleus segmentation, cell segmentation, feature extraction, feature selection and classification. The main concept of the segmentation algorithm employed uses white blood cell's morphological properties and the calibrated size of a real cell relative to image resolution. The segmentation process combined thresholding, morphological operation and ellipse curve fitting. Consequently, several features were extracted from the segmented nucleus and cytoplasm regions. Prominent features were then chosen by a greedy search algorithm called sequential forward selection. Finally, with a set of selected prominent features, both linear and naïve Bayes classifiers were applied for performance comparison. This system was tested on normal peripheral blood smear slide images from two datasets. Two sets of comparison were performed: segmentation and classification. The automatically segmented results were compared to the ones obtained manually by a haematologist. It was found that the proposed method is consistent and coherent in both datasets, with dice similarity of 98.9 and 91.6% for average segmented nucleus and cell regions, respectively. Furthermore, the overall correction rate in the classification phase is about 98 and 94% for linear and naïve Bayes models, respectively. The proposed system, based on normal white blood cell morphology and its characteristics, was applied to two different datasets. The results of the calibrated segmentation process on both datasets are fast, robust, efficient and coherent. Meanwhile, the classification of normal white blood cells into five types shows high sensitivity in both linear and naïve Bayes models, with slightly better results in the linear classifier.
Collision Based Blood Cell Distribution of the Blood Flow
NASA Astrophysics Data System (ADS)
Cinar, Yildirim
2003-11-01
Introduction: The goal of the study is the determination of the energy transferring process between colliding masses and the application of the results to the distribution of the cell, velocity and kinetic energy in arterial blood flow. Methods: Mathematical methods and models were used to explain the collision between two moving systems, and the distribution of linear momentum, rectilinear velocity, and kinetic energy in a collision. Results: According to decrease of mass of the second system, the velocity and momentum of constant mass of the first system are decreased, and linearly decreasing mass of the second system captures a larger amount of the kinetic energy and the rectilinear velocity of the collision system on a logarithmic scale. Discussion: The cause of concentration of blood cells at the center of blood flow an artery is not explained by Bernoulli principle alone but the kinetic energy and velocity distribution due to collision between the big mass of the arterial wall and the small mass of blood cells must be considered as well.
An Analysis for Capital Expenditure Decisions at a Naval Regional Medical Center.
1981-12-01
Service Equipment Review Committee 1. Portable defibrilator Computed tomographic scanner and cardioscope 2. ECG cart Automated blood cell counter 3. Gas...system sterilizer Gas system sterilizer 4. Automated blood cell Portable defibrilator and counter cardioscope 5. Computed tomographic ECG cart scanner...dictating and automated typing) systems. e. Filing equipment f. Automatic data processing equipment including data communications equipment. g
Ballen, Karen K.; Logan, Brent R.; Laughlin, Mary J.; He, Wensheng; Ambruso, Daniel R.; Armitage, Susan E.; Beddard, Rachel L.; Bhatla, Deepika; Hwang, William Y.K.; Kiss, Joseph E.; Koegler, Gesine; Kurtzberg, Joanne; Nagler, Arnon; Oh, David; Petz, Lawrence D.; Price, Thomas H.; Quinones, Ralph R.; Ratanatharathorn, Voravit; Rizzo, J. Douglas; Sazama, Kathleen; Scaradavou, Andromachi; Schuster, Michael W.; Sender, Leonard S.; Shpall, Elizabeth J.; Spellman, Stephen R.; Sutton, Millicent; Weitekamp, Lee Ann; Wingard, John R.; Eapen, Mary
2015-01-01
Variations in cord blood manufacturing and administration are common, and the optimal practice, not known. We compared processing and banking practices at 16 public cord blood banks (CBB) in the United States, and assessed transplant outcomes on 530 single umbilical cord blood (UCB) myeloablative transplantations for hematologic malignancies, facilitated by these banks. UCB banking practices were separated into three mutually exclusive groups based on whether processing was automated or manual; units were plasma and red blood cell reduced or buffy coat production method or plasma reduced. Compared to the automated processing system for units, the day-28 neutrophil recovery was significantly lower after transplantation of units that were manually processed and plasma reduced (red cell replete) (odds ratio [OR] 0.19 p=0.001) or plasma and red cell reduced (OR 0.54, p=0.05). Day-100 survival did not differ by CBB. However, day-100 survival was better with units that were thawed with the dextran-albumin wash method compared to the “no wash” or “dilution only” techniques (OR 1.82, p=0.04). In conclusion, CBB processing has no significant effect on early (day 100) survival despite differences in kinetics of neutrophil recovery. PMID:25543094
NASA Astrophysics Data System (ADS)
Alanis, Elvio; Romero, Graciela; Alvarez, Liliana; Martinez, Carlos C.; Hoyos, Daniel; Basombrio, Miguel A.
2001-08-01
A fully automated image processing system for detection of motile microorganism is biological samples is presented. The system is specifically calibrated for determining the concentration of Trypanosoma Cruzi parasites in blood samples of mice infected with Chagas disease. The method can be adapted for use in other biological samples. A thin layer of blood infected by T. cruzi parasites is examined in a common microscope in which the images of the vision field are taken by a CCD camera and temporarily stored in the computer memory. In a typical field, a few motile parasites are observable surrounded by blood red cells. The parasites have low contrast. Thus, they are difficult to detect visually but their great motility betrays their presence by the movement of the nearest neighbor red cells. Several consecutive images of the same field are taken, decorrelated with each other where parasites are present, and digitally processed in order to measure the number of parasites present in the field. Several fields are sequentially processed in the same fashion, displacing the sample by means of step motors driven by the computer. A direct advantage of this system is that its results are more reliable and the process is less time consuming than the current subjective evaluations made visually by technicians.
Laser Cutting Eliminates Nucleic Acid Cross-Contamination in Dried-Blood-Spot Processing
Daza, Glenda; Chang, Ming; Coombs, Robert
2012-01-01
Dried blood spots (DBS) are useful for molecular assays but are prone to false positives from cross-contamination. In our malaria DBS assay, cross-contamination was encountered despite cleaning techniques suitable for HIV-1. We therefore developed a contact-free laser cutting system that effectively eliminated cross-contamination during DBS processing. PMID:23052309
A Novel Macroscale Acoustic Device for Blood Filtration.
Dutra, Brian; Carmen Mora, Maria; Gerhardson, Tyler I; Sporbert, Brianna; Dufresne, Alexandre; Bittner, Katharine R; Lovewell, Carolanne; Rust, Michael J; Tirabassi, Michael V; Masi, Louis; Lipkens, Bart; Kennedy, Daniel R
2018-03-01
Retransfusion of a patient's own shed blood during cardiac surgery is attractive since it reduces the need for allogeneic transfusion, minimizes cost, and decreases transfusion related morbidity. Evidence suggests that lipid micro-emboli associated with the retransfusion of the shed blood are the predominant causes of the neurocognitive disorders. We have developed a novel acoustophoretic filtration system that can remove lipids from blood at clinically relevant flow rates. Unlike other acoustophoretic separation systems, this ultrasound technology works at the macroscale, and is therefore able to process larger flow rates than typical micro-electromechanical system (MEMS) scale acoustophoretic separation devices. In this work, we have first demonstrated the systematic design of the acoustic device and its optimization, followed by examining the feasibility of the device to filter lipids from the system. Then, we demonstrate the effects of the acoustic waves on the shed blood; examining hemolysis using both haptoglobin formation and lactate dehydrogenase release, as well as the potential of platelet aggregation or inflammatory cascade activation. Finally, in a porcine surgical model, we determined the potential viability of acoustic trapping as a blood filtration technology, as the animal responded to redelivered blood by increasing both systemic and mean arterial blood pressure.
NASA Astrophysics Data System (ADS)
Chaturvedi, Amal; Shukair, Shetha A.; Le Rolland, Paul; Vijayvergia, Mayank; Subramanian, Hariharan; Gunn, Jonathan W.
2016-03-01
Minimally invasive operations require surgeons to make difficult cuts to blood vessels and other tissues with impaired tactile and visual feedback. This leads to inadvertent cuts to blood vessels hidden beneath tissue, causing serious health risks to patients and a non-reimbursable financial burden to hospitals. Intraoperative imaging technologies have been developed, but these expensive systems can be cumbersome and provide only a high-level view of blood vessel networks. In this research, we propose a lean reflectance-based system, comprised of a dual wavelength LED, photodiode, and novel signal processing algorithms for rapid vessel characterization. Since this system takes advantage of the inherent pulsatile light absorption characteristics of blood vessels, no contrast agent is required for its ability to detect the presence of a blood vessel buried deep inside any tissue type (up to a cm) in real time. Once a vessel is detected, the system is able to estimate the distance of the vessel from the probe and the diameter size of the vessel (with a resolution of ~2mm), as well as delineate the type of tissue surrounding the vessel. The system is low-cost, functions in real-time, and could be mounted on already existing surgical tools, such as Kittner dissectors or laparoscopic suction irrigation cannulae. Having been successfully validated ex vivo, this technology will next be tested in a live porcine study and eventually in clinical trials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinstein, M.P.; Mirrett, S.; Reller, L.B.
1988-05-01
The Oxoid Signal blood culture system is a newly described, innovative method for visually detecting growth of microorganisms. We did 5,999 paired comparisons of equal volumes (10 ml) of blood in the Oxoid Signal and BACTEC radiometric blood culture systems at two university hospitals that use identical methods of obtaining and processing specimens. Overall, more microorganisms were detected in the BACTEC system (P less than 0.001), in particular, streptococci (P less than 0.01), fungi (P less than 0.001), and nonfermentative gram-negative rods, especially Acinetobacter species (P less than 0.001). Trends favoring the BACTEC system for detection of Pseudomonas aeruginosa, Haemophilusmore » species, and Neisseria species were noted. There were no differences in the yield of staphylococci, members of the family Enterobacteriaceae, and anaerobic bacteria. When both systems detected sepsis, the BACTEC did so earlier (P less than 0.001). This advantage was most notable at 24 h (70% of BACTEC positives detected versus 48% of Oxoid positives). The proportion of positives detected after 48 h, however, was similar (BACTEC, 84%; Oxoid, 78%). Revisions in the Oxoid Signal system itself or in the processing of Oxoid bottles appear to be necessary to improve its performance in detecting certain microorganism groups, especially fungi.« less
[Improving blood safety: errors management in transfusion medicine].
Bujandrić, Nevenka; Grujić, Jasmina; Krga-Milanović, Mirjana
2014-01-01
The concept of blood safety includes the entire transfusion chain starting with the collection of blood from the blood donor, and ending with blood transfusion to the patient. The concept involves quality management system as the systematic monitoring of adverse reactions and incidents regarding the blood donor or patient. Monitoring of near-miss errors show the critical points in the working process and increase transfusion safety. The aim of the study was to present the analysis results of adverse and unexpected events in transfusion practice with a potential risk to the health of blood donors and patients. One-year retrospective study was based on the collection, analysis and interpretation of written reports on medical errors in the Blood Transfusion Institute of Vojvodina. Errors were distributed according to the type, frequency and part of the working process where they occurred. Possible causes and corrective actions were described for each error. The study showed that there were not errors with potential health consequences for the blood donor/patient. Errors with potentially damaging consequences for patients were detected throughout the entire transfusion chain. Most of the errors were identified in the preanalytical phase. The human factor was responsible for the largest number of errors. Error reporting system has an important role in the error management and the reduction of transfusion-related risk of adverse events and incidents. The ongoing analysis reveals the strengths and weaknesses of the entire process and indicates the necessary changes. Errors in transfusion medicine can be avoided in a large percentage and prevention is cost-effective, systematic and applicable.
Risk analysis and detection of thrombosis by measurement of electrical resistivity of blood.
Sapkota, Achyut; Asakura, Yuta; Maruyama, Osamu; Kosaka, Ryo; Yamane, Takashi; Takei, Masahiro
2013-01-01
Monitoring of thrombogenic process is very important in ventricular assistance devices (VADs) used as temporary or permanent measures in patients with advanced heart failure. Currently, there is a lack of a system which can perform a real-time monitoring of thrombogenic activity. Electrical signals vary according to the change in concentration of coagulation factors as well as the distribution of blood cells, and thus have potential to detect the thrombogenic process in an early stage. In the present work, we have made an assessment of an instrumentation system exploiting the electrical properties of blood. The experiments were conducted using bovine blood. Electrical resistance tomography with eight-electrode sensor was used to monitor the spatio-temporal change in electrical resistivity of blood in thrombogenic and non-thrombogenic condition. Under non-thrombogenic condition, the resistivity was uniform across the cross-section and average resistivity monotonically decreased with time before remaining almost flat. In contrary, under thrombogenic condition, there was non-uniform distribution across the cross-section, and average resistivity fluctuated with time.
[Logistic and production process in a regional blood center: modeling and analysis].
Baesler, Felipe; Martínez, Cristina; Yaksic, Eduardo; Herrera, Claudia
2011-09-01
The blood supply chain is a complex system that considers different interconnected elements that have to be synchronized correctly to satisfy in quality and quantity the final patient requirements. To determine the blood center maximum production capacity, as well as the determination of the necessary changes for a future production capacity expansion. This work was developed in the Blood Center of Concepción, Chile, operations management tools were applied to model it and to propose improvement alternatives for the production process. The use of simulation is highlighted, which permitted the replication of the center behavior and the evaluation of expansion alternatives. It is possible to absorb a 100% increment in blood demand, without making major changes or investments in the production process. Also it was possible to determine the subsequent steps in terms of investments in equipment and human resources for a future expansion of the center coverage. The techniques used to model the production process of the blood center of Concepción, Chile, allowed us to analyze how it operates, to detect "bottle necks", and to support the decision making process for a future expansion of its capacity.
Portable laser speckle perfusion imaging system based on digital signal processor.
Tang, Xuejun; Feng, Nengyun; Sun, Xiaoli; Li, Pengcheng; Luo, Qingming
2010-12-01
The ability to monitor blood flow in vivo is of major importance in clinical diagnosis and in basic researches of life science. As a noninvasive full-field technique without the need of scanning, laser speckle contrast imaging (LSCI) is widely used to study blood flow with high spatial and temporal resolution. Current LSCI systems are based on personal computers for image processing with large size, which potentially limit the widespread clinical utility. The need for portable laser speckle contrast imaging system that does not compromise processing efficiency is crucial in clinical diagnosis. However, the processing of laser speckle contrast images is time-consuming due to the heavy calculation for enormous high-resolution image data. To address this problem, a portable laser speckle perfusion imaging system based on digital signal processor (DSP) and the algorithm which is suitable for DSP is described. With highly integrated DSP and the algorithm, we have markedly reduced the size and weight of the system as well as its energy consumption while preserving the high processing speed. In vivo experiments demonstrate that our portable laser speckle perfusion imaging system can obtain blood flow images at 25 frames per second with the resolution of 640 × 480 pixels. The portable and lightweight features make it capable of being adapted to a wide variety of application areas such as research laboratory, operating room, ambulance, and even disaster site.
Li, Qing-bo; Liu, Jie-qiang; Li, Xiang
2012-03-01
A small non-invasive measurement system for human blood glucose has been developed, which can achieve fast, real-time and non invasive measurement of human blood glucose. The device is mainly composed of four parts, i. e. fixture, light system, data acquisition and processing systems, and spectrometer. A new scheme of light source driving was proposed, which can meet the requirements of light source under a variety of conditions of spectral acquisition. An integrated fixture design was proposed, which not only simplifies the optical structure of the system, but also improves the reproducibility of measurement conditions. The micro control system mainly achieves control function, dealing with data, data storage and so on. As the most important component, microprocessor DSP TMS320F2812 has many advantages, such as low power, high processing speed, high computing ability and so on. Wavelet denoising is used to pretreat the spectral data, which can decrease the loss of incident light and improve the signal-to-noise ratio. Kernel partial least squares method was adopted to build the mathematical model, which can improve the precision of the system. In the calibration experiment of the system, the standard values were measured by One-Touch. The correlation coefficient between standard blood glucose values and truth values is 0.95. The root mean square error of measurement is 0.6 mmol x L(-1). The system has good reproducibility.
Patient safety with blood products administration using wireless and bar-code technology.
Porcella, Aleta; Walker, Kristy
2005-01-01
Supported by a grant from the Agency for Healthcare Research and Quality, a University of Iowa Hospitals and Clinics interdisciplinary research team created an online data-capture-response tool utilizing wireless mobile devices and bar code technology to track and improve blood products administration process. The tool captures 1) sample collection, 2) sample arrival in the blood bank, 3) blood product dispense from blood bank, and 4) administration. At each step, the scanned patient wristband ID bar code is automatically compared to scanned identification barcode on requisition, sample, and/or product, and the system presents either a confirmation or an error message to the user. Following an eight-month, 5 unit, staged pilot, a 'big bang,' hospital-wide implementation occurred on February 7, 2005. Preliminary results from pilot data indicate that the new barcode process captures errors 3 to 10 times better than the old manual process.
True color blood flow imaging using a high-speed laser photography system
NASA Astrophysics Data System (ADS)
Liu, Chien-Sheng; Lin, Cheng-Hsien; Sun, Yung-Nien; Ho, Chung-Liang; Hsu, Chung-Chi
2012-10-01
Physiological changes in the retinal vasculature are commonly indicative of such disorders as diabetic retinopathy, glaucoma, and age-related macular degeneration. Thus, various methods have been developed for noninvasive clinical evaluation of ocular hemodynamics. However, to the best of our knowledge, current ophthalmic instruments do not provide a true color blood flow imaging capability. Accordingly, we propose a new method for the true color imaging of blood flow using a high-speed pulsed laser photography system. In the proposed approach, monochromatic images of the blood flow are acquired using a system of three cameras and three color lasers (red, green, and blue). A high-quality true color image of the blood flow is obtained by assembling the monochromatic images by means of image realignment and color calibration processes. The effectiveness of the proposed approach is demonstrated by imaging the flow of mouse blood within a microfluidic channel device. The experimental results confirm the proposed system provides a high-quality true color blood flow imaging capability, and therefore has potential for noninvasive clinical evaluation of ocular hemodynamics.
NHS Blood Tracking Pilot: City University Evaluation Project
NASA Astrophysics Data System (ADS)
Goddard, Kate; Shabestari, Omid; Adriano, Juan; Kay, Jonathan; Roudsari, Abdul
Automation of healthcare processes is an emergent theme in the drive to increase patient safety. The Mayday Hospital has been chosen as the pilot site for the implementation of the Electronic Clinical Transfusion Management System to track blood from the point of ordering to the final transfusion. The Centre for Health Informatics at City University is carrying out an independent evaluation of the system implementation using a variety of methodologies to both formatively inform the implementation process and summatively provide an account of the lessons learned for future implementations.
Point-of-care, portable microfluidic blood analyzer system
NASA Astrophysics Data System (ADS)
Maleki, Teimour; Fricke, Todd; Quesenberry, J. T.; Todd, Paul W.; Leary, James F.
2012-03-01
Recent advances in MEMS technology have provided an opportunity to develop microfluidic devices with enormous potential for portable, point-of-care, low-cost medical diagnostic tools. Hand-held flow cytometers will soon be used in disease diagnosis and monitoring. Despite much interest in miniaturizing commercially available cytometers, they remain costly, bulky, and require expert operation. In this article, we report progress on the development of a battery-powered handheld blood analyzer that will quickly and automatically process a drop of whole human blood by real-time, on-chip magnetic separation of white blood cells (WBCs), fluorescence analysis of labeled WBC subsets, and counting a reproducible fraction of the red blood cells (RBCs) by light scattering. The whole blood (WB) analyzer is composed of a micro-mixer, a special branching/separation system, an optical detection system, and electronic readout circuitry. A droplet of un-processed blood is mixed with the reagents, i.e. magnetic beads and fluorescent stain in the micro-mixer. Valve-less sorting is achieved by magnetic deflection of magnetic microparticle-labeled WBC. LED excitation in combination with an avalanche photodiode (APD) detection system is used for counting fluorescent WBC subsets using several colors of immune-Qdots, while counting a reproducible fraction of red blood cells (RBC) is performed using a laser light scatting measurement with a photodiode. Optimized branching/channel width is achieved using Comsol Multi-Physics™ simulation. To accommodate full portability, all required power supplies (40v, +/-10V, and +3V) are provided via step-up voltage converters from one battery. A simple onboard lock-in amplifier is used to increase the sensitivity/resolution of the pulse counting circuitry.
Sample to answer visualization pipeline for low-cost point-of-care blood cell counting
NASA Astrophysics Data System (ADS)
Smith, Suzanne; Naidoo, Thegaran; Davies, Emlyn; Fourie, Louis; Nxumalo, Zandile; Swart, Hein; Marais, Philip; Land, Kevin; Roux, Pieter
2015-03-01
We present a visualization pipeline from sample to answer for point-of-care blood cell counting applications. Effective and low-cost point-of-care medical diagnostic tests provide developing countries and rural communities with accessible healthcare solutions [1], and can be particularly beneficial for blood cell count tests, which are often the starting point in the process of diagnosing a patient [2]. The initial focus of this work is on total white and red blood cell counts, using a microfluidic cartridge [3] for sample processing. Analysis of the processed samples has been implemented by means of two main optical visualization systems developed in-house: 1) a fluidic operation analysis system using high speed video data to determine volumes, mixing efficiency and flow rates, and 2) a microscopy analysis system to investigate homogeneity and concentration of blood cells. Fluidic parameters were derived from the optical flow [4] as well as color-based segmentation of the different fluids using a hue-saturation-value (HSV) color space. Cell count estimates were obtained using automated microscopy analysis and were compared to a widely accepted manual method for cell counting using a hemocytometer [5]. The results using the first iteration microfluidic device [3] showed that the most simple - and thus low-cost - approach for microfluidic component implementation was not adequate as compared to techniques based on manual cell counting principles. An improved microfluidic design has been developed to incorporate enhanced mixing and metering components, which together with this work provides the foundation on which to successfully implement automated, rapid and low-cost blood cell counting tests.
Pineda, A A; Valbonesi, M
1990-04-01
Interest in and use of IBS have increased recently. This form of haemotherapy involves the retrieval of blood shed perioperatively. IBS, together with other forms of ABT, has gained a prominent role in transfusion medicine, largely due to an increased awareness of the risks associated with transfusion of homologous blood. In addition to conserving erythrocytes, IBS prevents disease transmission, other adverse transfusion reactions, and alloimmunization to antigens in blood cells and plasma which may result from homologous blood use. An array of IBS devices is presently available, ranging from disposable canisters to complete processing systems. The devices are capable of recovering, filtering, washing and reinfusing shed erythrocytes. They can be divided into slow-flow and rapid-flow systems based on the rapidity of blood processing. Most systems use a dual channel aspiration cannula through which shed blood is aspirated and mixed with anticoagulant solution. The salvage procedure requires operator control at every step, even for the highly automated instruments. Various health care personnel have been trained to operate IBS equipment; a transfusion service nurse with blood bank expertise has proved to be a highly reliable operator in our practice. Extensive clinical observation has shown that salvaged erythrocytes function and survive normally. IBS has been applied in many surgical fields; it has two relative contraindications: its use in areas affected by infection or malignancy. Operative procedures characterized by large blood losses provide a cost-efficient application of IBS, including cardiac surgery, orthopaedic procedures, trauma, vascular surgery, and liver transplantation. New, highly efficient technology is emerging that is capable of recovering other blood components. Consequently, what presently amounts to erythrocyte recovery will be expanded shortly to include platelets and plasma, with its many constituents.
Characteristics of canine platelet-rich plasma prepared with five commercially available systems.
Franklin, Samuel P; Garner, Bridget C; Cook, James L
2015-09-01
To characterize platelet-rich plasma (PRP) products obtained from canine blood by use of a variety of commercially available devices. Blood samples from 15 dogs between 18 months and 9 years of age with no concurrent disease, except for osteoarthritis in some dogs. PRP products were produced from blood obtained from each of the 15 dogs by use of each of 5 commercially available PRP-concentrating systems. Complete blood counts were performed on each whole blood sample and PRP product. The degree of platelet, leukocyte, and erythrocyte concentration or reduction for PRP, compared with results for the whole blood sample, was quantified for each dog and summarized for each concentrating system. The various PRP-concentrating systems differed substantially in the amount of blood processed, method of PRP preparation, amount of PRP produced, and platelet, leukocyte, and erythrocyte concentrations or reductions for PRP relative to results for whole blood. The characteristics of PRP products differed considerably. Investigators evaluating the efficacy of PRPs need to specify the characteristics of the product they are assessing. Clinicians should be aware of the data (or lack of data) supporting use of a particular PRP for a specific medical condition.
Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Noori Hekmat, Somayeh; Esmailzdeh, Hamid
2014-12-25
Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts' panel views via the interview and focus group discussion sessions. The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ ("Theory of Inventive Problem Solving.") The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency.
Dehnavieh, Reza; Ebrahimipour, Hossein; Molavi-Taleghani, Yasamin; Vafaee-Najar, Ali; Hekmat, Somayeh Noori; Esmailzdeh, Hamid
2015-01-01
Introduction: Pediatric emergency has been considered as a high risk area, and blood transfusion is known as a unique clinical measure, therefore this study was conducted with the purpose of assessing the proactive risk assessment of blood transfusion process in Pediatric Emergency of Qaem education- treatment center in Mashhad, by the Healthcare Failure Mode and Effects Analysis (HFMEA) methodology. Methodology: This cross-sectional study analyzed the failure mode and effects of blood transfusion process by a mixture of quantitative-qualitative method. The proactive HFMEA was used to identify and analyze the potential failures of the process. The information of the items in HFMEA forms was collected after obtaining a consensus of experts’ panel views via the interview and focus group discussion sessions. Results: The Number of 77 failure modes were identified for 24 sub-processes enlisted in 8 processes of blood transfusion. Totally 13 failure modes were identified as non-acceptable risk (a hazard score above 8) in the blood transfusion process and were transferred to the decision tree. Root causes of high risk modes were discussed in cause-effect meetings and were classified based on the UK national health system (NHS) approved classifications model. Action types were classified in the form of acceptance (11.6%), control (74.2%) and elimination (14.2%). Recommendations were placed in 7 categories using TRIZ (“Theory of Inventive Problem Solving.”) Conclusion: The re-engineering process for the required changes, standardizing and updating the blood transfusion procedure, root cause analysis of blood transfusion catastrophic events, patient identification bracelet, training classes and educational pamphlets for raising awareness of personnel, and monthly gathering of transfusion medicine committee have all been considered as executive strategies in work agenda in pediatric emergency. PMID:25560332
NASA Astrophysics Data System (ADS)
Voeikov, Vladimir L.; Kondakov, Sergey E.; Buravleva, Ekaterina; Kaganovsky, Isaak; Reznikov, Mikhail
2000-05-01
An automatic device for high-temporal resolution of the process of red blood sedimentation was designed. The position of the boundary between red blood and plasma may be registered each 30 sec in several pipettes simultaneously with +/- 10 mkm precision. Fractional rates of the boundary movement are deduced with high accuracy. Data are processed by a PC and presented as velocity-time curves (ESR-grams) and the curves describing time evolution of the boundary position. Several unexpected phenomena in the process of red blood sedimentation have been revealed. Upward fast movements of the boundary up to 1 mm were noted. In patients' blood sets of 5 - 10 milliHz oscillations of sedimentation rate were usually developing at early stages of blood sedimentation. In non-diluted healthy donors' blood high amplitude periodic oscillations were either absent, or were emerging only after blood resided in pipettes for several hours. When blood was diluted to a certain degree with physiological saline or with own plasma long-term low frequency (1 - 3 milliHz) rate oscillations regularly appeared. Non-trivial dependence of patterns of ESR-grams on diluting of blood with own plasma or saline was observed. Thus, non-linear dynamic behavior of living blood has been revealed due to application of the principles of the system of technical vision for the detailed analysis of red blood sedimentation kinetics.
Rinehart, Joseph B; Lee, Tiffany C; Kaneshiro, Kayleigh; Tran, Minh-Ha; Sun, Coral; Kain, Zeev N
2016-04-01
As part of ongoing perioperative surgical home implantation process, we applied a previously published algorithm for creation of a maximum surgical blood order schedule (MSBOS) to our operating rooms. We hypothesized that using the MSBOS we could show a reduction in unnecessary preoperative blood testing and associated costs. Data regarding all surgical cases done at UC Irvine Health's operating rooms from January 1, 2011, to January 1, 2014 were extracted from the anesthesia information management systems (AIMS). After the data were organized into surgical specialties and operative sites, blood order recommendations were generated based on five specific case characteristics of the group. Next, we assessed current ordering practices in comparison to actual blood utilization to identify potential areas of wastage and performed a cost analysis comparing the annual hospital costs from preoperative blood orders if the blood order schedule were to be followed to historical practices. Of the 19,138 patients who were categorized by the MSBOS as needing no blood sample, 2694 (14.0%) had a type and screen (T/S) ordered and 1116 (5.8%) had a type and crossmatch ordered. Of the 6073 procedures where MSBOS recommended only a T/S, 2355 (38.8%) had blood crossmatched. The cost analysis demonstrated an annual reduction in actual hospital costs of $57,335 with the MSBOS compared to historical blood ordering practices. We showed that the algorithm for development of a multispecialty blood order schedule is transferable and yielded reductions in preoperative blood product screening at our institution. © 2016 AABB.
[Design of blood-pressure parameter auto-acquisition circuit].
Chen, Y P; Zhang, D L; Bai, H W; Zhang, D A
2000-02-01
This paper presents the realization and design of a kind of blood-pressure parameter auto-acquisition circuit. The auto-acquisition of blood-pressure parameter controlled by 89C2051 single chip microcomputer is accomplished by collecting and processing the driving signal of LCD. The circuit that is successfully applied in the home unit of telemedicine system has the simple and reliable properties.
Model-Based, Noninvasive Monitoring of Intracranial Pressure
2013-07-01
patients. A physiologically based model relates ICP to simultaneously measured waveforms of arterial blood pressure ( ABP ), obtained via radial... ABP and CBFV are currently measured as the clinical standard of care. The project’s major accomplishments include: assembling a suitable system for...synchronized arterial blood pressure ( ABP ) and cerebral blood flow velocity (CBFV) waveform measurements that can be obtained quite routinely. Our processing
What determines blood vessel structure? Genetic prespecification vs. hemodynamics.
Jones, Elizabeth A V; le Noble, Ferdinand; Eichmann, Anne
2006-12-01
Vascular network remodeling, angiogenesis, and arteriogenesis play an important role in the pathophysiology of ischemic cardiovascular diseases and cancer. Based on recent studies of vascular network development in the embryo, several novel aspects to angiogenesis have been identified as crucial to generate a functional vascular network. These aspects include specification of arterial and venous identity in vessels and network patterning. In early embryogenesis, vessel identity and positioning are genetically hardwired and involve neural guidance genes expressed in the vascular system. We demonstrated that, during later stages of embryogenesis, blood flow plays a crucial role in regulating vessel identity and network remodeling. The flow-evoked remodeling process is dynamic and involves a high degree of vessel plasticity. The open question in the field is how genetically predetermined processes in vessel identity and patterning balance with the contribution of blood flow in shaping a functional vascular architecture. Although blood flow is essential, it remains unclear to what extent flow is able to act on the developing cardiovascular system. There is significant evidence that mechanical forces created by flowing blood are biologically active within the embryo and that the level of mechanical forces and the type of flow patterns present in the embryo are able to affect gene expression. Here, we highlight the pivotal role for blood flow and physical forces in shaping the cardiovascular system.
Rapid Separation of Bacteria from Blood—Review and Outlook
Alizadeh, Mahsa; Husseini, Ghaleb A.; McClellan, Daniel S.; Buchanan, Clara M.; Bledsoe, Colin G.; Robison, Richard A.; Blanco, Rae; Roeder, Beverly L.; Melville, Madison; Hunter, Alex K.
2017-01-01
The high morbidity and mortality rate of bloodstream infections involving antibiotic-resistant bacteria necessitate a rapid identification of the infectious organism and its resistance profile. Traditional methods based on culturing the blood typically require at least 24 h, and genetic amplification by PCR in the presence of blood components has been problematic. The rapid separation of bacteria from blood would facilitate their genetic identification by PCR or other methods so that the proper antibiotic regimen can quickly be selected for the septic patient. Microfluidic systems that separate bacteria from whole blood have been developed, but these are designed to process only microliter quantities of whole blood or only highly diluted blood. However, symptoms of clinical blood infections can be manifest with bacterial burdens perhaps as low as 10 CFU/mL, and thus milliliter quantities of blood must be processed to collect enough bacteria for reliable genetic analysis. This review considers the advantages and shortcomings of various methods to separate bacteria from blood, with emphasis on techniques that can be done in less than 10 min on milliliter-quantities of whole blood. These techniques include filtration, screening, centrifugation, sedimentation, hydrodynamic focusing, chemical capture on surfaces or beads, field-flow fractionation, and dielectrophoresis. Techniques with the most promise include screening, sedimentation, and magnetic bead capture, as they allow large quantities of blood to be processed quickly. Some microfluidic techniques can be scaled up. PMID:27160415
Huang, Chih-Chung; Lee, Po-Yang; Chen, Pay-Yu; Liu, Ting-Yu
2012-01-01
Blood flow measurement using Doppler ultrasound has become a useful tool for diagnosing cardiovascular diseases and as a physiological monitor. Recently, pocket-sized ultrasound scanners have been introduced for portable diagnosis. The present paper reports the implementation of a portable ultrasound pulsed-wave (PW) Doppler flowmeter using a smartphone. A 10-MHz ultrasonic surface transducer was designed for the dynamic monitoring of blood flow velocity. The directional baseband Doppler shift signals were obtained using a portable analog circuit system. After hardware processing, the Doppler signals were fed directly to a smartphone for Doppler spectrogram analysis and display in real time. To the best of our knowledge, this is the first report of the use of this system for medical ultrasound Doppler signal processing. A Couette flow phantom, consisting of two parallel disks with a 2-mm gap, was used to evaluate and calibrate the device. Doppler spectrograms of porcine blood flow were measured using this stand-alone portable device under the pulsatile condition. Subsequently, in vivo portable system verification was performed by measuring the arterial blood flow of a rat and comparing the results with the measurement from a commercial ultrasound duplex scanner. All of the results demonstrated the potential for using a smartphone as a novel embedded system for portable medical ultrasound applications. © 2012 IEEE
Baek, Jin Hyen; Yalamanoglu, Ayla; Moon, So-Eun; Gao, Yamei; Buehler, Paul W
2018-03-01
Red blood cell (RBC) oxygen (O 2 ) delivery may be impacted at the tissue, cellular, and molecular levels after storage duration, preservation strategies, and pathogen reduction. Collectively, the preclinical measurement of arterial and venous PO 2 , systemic blood flow, tissue hypoxia-inducible factors (HIFs), pimonidazole adduction, and erythropoietin (EPO) regulation can serve to elucidate differential RBC quality after storage and processing. Donor guinea pig blood was collected, leukoreduced, and stored at 4°C in AS-3 for 1 (fresh) or 14 (stored) days. RBC variables-2,3-diphosphoglycerate, adenosine triphosphate, hemoglobin, morphology, deformability, and in vivo recovery at 24 hours-were measured at each storage duration. Recipient guinea pigs were exchange transfused until 80% volume replacement was achieved. Arterial and venous blood gases, systemic blood flow, renal HIF-1α and HIF-2α, renal EPO mRNA, plasma EPO, and renal tissue pimonidazole adduction were measured after transfusion. RBC variables declined significantly with storage; however, hemolysis and in vivo recovery remained within the allowable limits for human blood storage. Posttransfusion arterial and venous PO 2 and systemic blood flow decreased, and renal HIFs, EPO mRNA, and pimonidazole adducts increased. Subsequently, EPO accumulated in plasma indicating decreased O 2 availability in the kidneys. Conversely, all variables remained at basal levels in the fresh blood group. The evaluation of renal O 2 homeostasis after transfusion represents an effective approach to defining RBC quality between predicate and novel processing. Methods are adapted from standardized techniques and ideal for preclinical evaluation. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.
Cryopreservation of red blood cells.
Lagerberg, Johan W
2015-01-01
Cryopreservation of red blood cell concentrates (RBCs) is an important method for maintaining an inventory of rare RBC units and managing special transfusion circumstances. The permeating additive glycerol is used as a cryoprotectant to protect RBCs against freezing damage. The use of thawed RBCs was hampered a 24-h outdating period due to potential bacterial contamination when a functionally open system was used for addition and removal of the glycerol. With the introduction of a functionally closed system for the glycerolization and deglycerolization of RBC units, extended post-thaw storage became possible. Here, we describe the cryopreservation of red blood cells according to the high-glycerol method, using a functionally closed processing system.
Bennardello, Francesco; Fidone, Carmelo; Cabibbo, Sergio; Calabrese, Salvatore; Garozzo, Giovanni; Cassarino, Grazia; Antolino, Agostino; Tavolino, Giuseppe; Zisa, Nuccio; Falla, Cadigia; Drago, Giuseppe; Di Stefano, Giovanna; Bonomo, Pietro
2009-01-01
Background One of the most serious risks of blood transfusions is an error in ABO blood group compatibility, which can cause a haemolytic transfusion reaction and, in the most severe cases, the death of the patient. The frequency and type of errors observed suggest that these are inevitable, in that mistakes are inherent to human nature, unless significant changes, including the use of computerised instruments, are made to procedures. Methods In order to identify patients who are candidates for the transfusion of blood components and to guarantee the traceability of the transfusion, the Securblood system (BBS srl) was introduced. This system records the various stages of the transfusion process, the health care workers involved and any immediate transfusion reactions. The patients and staff are identified by fingerprinting or a bar code. The system was implemented within Ragusa hospital in 16 operative units (ordinary wards, day hospital, operating theatres). Results In the period from August 2007 to July 2008, 7282 blood components were transfused within the hospital, of which 5606 (77%) using the Securblood system. Overall, 1777 patients were transfused. In this year of experience, no transfusion errors were recorded and each blood component was transfused to the right patient. We recorded 33 blocks of the terminals (involving 0.6% of the transfused blood components) which required the intervention of staff from the Service of Immunohaematology and Transfusion Medicine (SIMT). Most of the blocks were due to procedural errors. Conclusions The Securblood system guarantees complete traceability of the transfusion process outside the SIMT and eliminates the possibility of mistaken identification of patients or blood components. The use of fingerprinting to identify health care staff (nurses and doctors) and patients obliges the staff to carry out the identification procedures directly in the presence of the patient and guarantees the presence of the doctor at the start of the transfusion. PMID:19657483
Bennardello, Francesco; Fidone, Carmelo; Cabibbo, Sergio; Calabrese, Salvatore; Garozzo, Giovanni; Cassarino, Grazia; Antolino, Agostino; Tavolino, Giuseppe; Zisa, Nuccio; Falla, Cadigia; Drago, Giuseppe; Di Stefano, Giovanna; Bonomo, Pietro
2009-07-01
One of the most serious risks of blood transfusions is an error in ABO blood group compatibility, which can cause a haemolytic transfusion reaction and, in the most severe cases, the death of the patient. The frequency and type of errors observed suggest that these are inevitable, in that mistakes are inherent to human nature, unless significant changes, including the use of computerised instruments, are made to procedures. In order to identify patients who are candidates for the transfusion of blood components and to guarantee the traceability of the transfusion, the Securblood system (BBS srl) was introduced. This system records the various stages of the transfusion process, the health care workers involved and any immediate transfusion reactions. The patients and staff are identified by fingerprinting or a bar code. The system was implemented within Ragusa hospital in 16 operative units (ordinary wards, day hospital, operating theatres). In the period from August 2007 to July 2008, 7282 blood components were transfused within the hospital, of which 5606 (77%) using the Securblood system. Overall, 1777 patients were transfused. In this year of experience, no transfusion errors were recorded and each blood component was transfused to the right patient. We recorded 33 blocks of the terminals (involving 0.6% of the transfused blood components) which required the intervention of staff from the Service of Immunohaematology and Transfusion Medicine (SIMT). Most of the blocks were due to procedural errors. The Securblood system guarantees complete traceability of the transfusion process outside the SIMT and eliminates the possibility of mistaken identification of patients or blood components. The use of fingerprinting to identify health care staff (nurses and doctors) and patients obliges the staff to carry out the identification procedures directly in the presence of the patient and guarantees the presence of the doctor at the start of the transfusion.
Blood donation in Chile: Replacement and volunteer donors.
Herrera, Claudia; Martínez, Cristina; Armanet, Leonor; Cárcamo, Amalia; Boye, Patricia; Lyng, Cecilia
2010-01-01
In recent years, the Chilean Health Ministry has developed a strategy in order to improve the safety and opportunity of the blood supply through the creation of a nationally co-ordinated blood transfusion service, centralizing collection management, production and testing in three Blood Centers along the country and promoting voluntary, regular, blood donation. In 2007, a comprehensive study of the situation of Blood Transfusion Services in Chile concluded that several critical factors make it difficult to achieve a safe and adequate access to blood and blood components in the country. For example there is a low donation rate (14.3/1000 inhabitants), very low percentage of voluntary donors (10%), excessive amount of blood banks collecting, processing and testing blood revealing an atomized non-centralized system, lack of a national IT system and insufficient national standards. There are two regions in the country, Bio Bio and Valparaíso, where Regional Blood Centers are located, that have put in place several strategies in order to obtain better results. Copyright 2009 The International Association for Biologicals. Published by Elsevier Ltd. All rights reserved.
New decision support tool for acute lymphoblastic leukemia classification
NASA Astrophysics Data System (ADS)
Madhukar, Monica; Agaian, Sos; Chronopoulos, Anthony T.
2012-03-01
In this paper, we build up a new decision support tool to improve treatment intensity choice in childhood ALL. The developed system includes different methods to accurately measure furthermore cell properties in microscope blood film images. The blood images are exposed to series of pre-processing steps which include color correlation, and contrast enhancement. By performing K-means clustering on the resultant images, the nuclei of the cells under consideration are obtained. Shape features and texture features are then extracted for classification. The system is further tested on the classification of spectra measured from the cell nuclei in blood samples in order to distinguish normal cells from those affected by Acute Lymphoblastic Leukemia. The results show that the proposed system robustly segments and classifies acute lymphoblastic leukemia based on complete microscopic blood images.
Activity-based costs of blood transfusions in surgical patients at four hospitals.
Shander, Aryeh; Hofmann, Axel; Ozawa, Sherri; Theusinger, Oliver M; Gombotz, Hans; Spahn, Donat R
2010-04-01
Blood utilization has long been suspected to consume more health care resources than previously reported. Incomplete accounting for blood costs has the potential to misdirect programmatic decision making by health care systems. Determining the cost of supplying patients with blood transfusions requires an in-depth examination of the complex array of activities surrounding the decision to transfuse. To accurately determine the cost of blood in a surgical population from a health system perspective, an activity-based costing (ABC) model was constructed. Tasks and resource consumption (materials, labor, third-party services, capital) related to blood administration were identified prospectively at two US and two European hospitals. Process frequency (i.e., usage) data were captured retrospectively from each hospital and used to populate the ABC model. All major process steps, staff, and consumables to provide red blood cell (RBC) transfusions to surgical patients, including usage frequencies, and direct and indirect overhead costs contributed to per-RBC-unit costs between $522 and $1183 (mean, $761 +/- $294). These exceed previously reported estimates and were 3.2- to 4.8-fold higher than blood product acquisition costs. Annual expenditures on blood and transfusion-related activities, limited to surgical patients, ranged from $1.62 to $6.03 million per hospital and were largely related to the transfusion rate. Applicable to various hospital practices, the ABC model confirms that blood costs have been underestimated and that they are geographically variable and identifies opportunities for cost containment. Studies to determine whether more stringent control of blood utilization improves health care utilization and quality, and further reduces costs, are warranted.
Smith, André; Fiddler, Jay; Walby, Kevin; Hier, Sean
2011-11-01
This article examines the process of rebuilding institutional trust in the Canadian blood system in the aftermath of the tainted blood scandal. Our focus is the policy of lifetime deferral from donating blood for men who have sex with men. Drawing on findings from interviews with representatives of Health Canada's Expert Advisory Committee on Blood Regulation, the National Liaison Committee, Canadian Blood Services, and blood consumer groups, we demonstrate how claims making about rights, discrimination, science, and risk contribute to policy continuity. We also examine the link between policy continuity and the management of reputational risk.
Broyer, Patrick; Perrot, Nadine; Rostaing, Hervé; Blaze, Jérome; Pinston, Frederic; Gervasi, Gaspard; Charles, Marie-Hélène; Dachaud, Fabien; Dachaud, Jacques; Moulin, Frederic; Cordier, Sylvain; Dauwalder, Olivier; Meugnier, Hélène; Vandenesch, Francois
2018-01-01
Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek ® MS slides directly from positive blood culture broth based on an "all-in-one" extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT ® 3D (SA/SN blood culture bottles) or the BacT/ALERT Virtuo TM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT ® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo ® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially be improved by converting direct ID of positive blood cultures from a batch-based to real-time and "on-demand" process.
McGarraugh, Geoffrey V; Clarke, William L; Kovatchev, Boris P
2010-05-01
The purpose of the analysis was to compare the clinical utility of data from traditional self-monitoring of blood glucose (SMBG) to that of continuous glucose monitoring (CGM). A clinical study of the clinical accuracy of the FreeStyle Navigator CGM System (Abbott Diabetes Care, Alameda, CA), which includes SMBG capabilities, was conducted by comparison to the YSI blood glucose analyzer (YSI Inc., Yellow Springs, OH) using 58 subjects with type 1 diabetes. The Continuous Glucose-Error Grid Analysis (CG-EGA) was used as the analytical tool. Using CG-EGA, the "clinically accurate," "benign errors," and "clinical errors" were 86.8%, 8.7%, and 4.5% for SMBG and 92.7%, 3.7%, and 3.6% for CGM, respectively. If blood glucose is viewed as a process in time, SMBG would provide accurate information about this process 86.8% of the time, whereas CGM would provide accurate information about this process 92.7% of the time (P < 0.0001). In the hypoglycemic range, however, SMBG is more accurate as the "clinically accurate," "benign errors," and "clinical errors" were 83.5%, 6.4%, and 10.1% for SMBG and 57.1%, 8.4%, and 34.5% (P < 0.0001) for CGM, respectively. While SMBG produces more accurate instantaneous glucose values than CGM, control of blood glucose involves a system in flux, and CGM provides more detailed insight into the dynamics of that system. In the normal and elevated glucose ranges, the additional information about the direction and rate of glucose change provided by the FreeStyle Navigator CGM System increases the ability to make correct clinical decisions when compared to episodic SMBG tests.
Embedded programmable blood pressure monitoring system
NASA Astrophysics Data System (ADS)
Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk
2010-02-01
A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.
Automatic real time evaluation of red blood cell elasticity by optical tweezers
NASA Astrophysics Data System (ADS)
Moura, Diógenes S.; Silva, Diego C. N.; Williams, Ajoke J.; Bezerra, Marcos A. C.; Fontes, Adriana; de Araujo, Renato E.
2015-05-01
Optical tweezers have been used to trap, manipulate, and measure individual cell properties. In this work, we show that the association of a computer controlled optical tweezers system with image processing techniques allows rapid and reproducible evaluation of cell deformability. In particular, the deformability of red blood cells (RBCs) plays a key role in the transport of oxygen through the blood microcirculation. The automatic measurement processes consisted of three steps: acquisition, segmentation of images, and measurement of the elasticity of the cells. An optical tweezers system was setup on an upright microscope equipped with a CCD camera and a motorized XYZ stage, computer controlled by a Labview platform. On the optical tweezers setup, the deformation of the captured RBC was obtained by moving the motorized stage. The automatic real-time homemade system was evaluated by measuring RBCs elasticity from normal donors and patients with sickle cell anemia. Approximately 150 erythrocytes were examined, and the elasticity values obtained by using the developed system were compared to the values measured by two experts. With the automatic system, there was a significant time reduction (60 × ) of the erythrocytes elasticity evaluation. Automated system can help to expand the applications of optical tweezers in hematology and hemotherapy.
The Profile of Student Misconceptions on The Human and Plant Transport Systems
NASA Astrophysics Data System (ADS)
Ainiyah, M.; Ibrahim, M.; Hidayat, M. T.
2018-01-01
This research aims to identify misconceptions on the humans and plants transportation systems. The research was done in the 8th grade in Indonesia. Data were collected to use a three-tier test. This type of research was used survey design. Content analysis was used to analyze the misconception data. The results of this research were the location of misconception of each student is different. The highest misconceptions identified in this research, namely: a) arteries that drain blood to the heart (73.3%); b) veins that drain blood from the heart (70.0%); c) place of oxygen and carbon dioxide exchange occurs in the veins (66.7%); d) blood pressure in veins greater than in capillaries (63.3%); e) absorption of water occurs diffusion and absorption of minerals occurs osmosis (76.7%); f) transport of photosynthesis process occurs by diffusion (66.7%); g) photosynthesis process occurs during the day (63.3%); and h) process of evaporation of water through the leaves are guttation (56.7%). The results of this research show that the level of students misconceptions on the of human and plant transport systems is still high so that it can serve as a reference to improve the learning process and the reduction of student misconceptions.
Castillo, Tiffany N; Pouliot, Michael A; Kim, Hyeon Joo; Dragoo, Jason L
2011-02-01
Clinical studies claim that platelet-rich plasma (PRP) shortens recovery times because of its high concentration of growth factors that may enhance the tissue repair process. Most of these studies obtained PRP using different separation systems, and few analyzed the content of the PRP used as treatment. This study characterized the composition of single-donor PRP produced by 3 commercially available PRP separation systems. Controlled laboratory study. Five healthy humans donated 100 mL of blood, which was processed to produce PRP using 3 PRP concentration systems (MTF Cascade, Arteriocyte Magellan, Biomet GPS III). Platelet, white blood cell (WBC), red blood cell, and fibrinogen concentrations were analyzed by automated systems in a clinical laboratory, whereas ELISA determined the concentrations of platelet-derived growth factor αβ and ββ (PDGF-αβ, PDGF-ββ), transforming growth factor β1 (TGF-β1), and vascular endothelial growth factor (VEGF). There was no significant difference in mean PRP platelet, red blood cell, active TGF-β1, or fibrinogen concentrations among PRP separation systems. There was a significant difference in platelet capture efficiency. The highest platelet capture efficiency was obtained with Cascade, which was comparable with Magellan but significantly higher than GPS III. There was a significant difference among all systems in the concentrations of WBC, PDGF-αβ, PDGF-ββ, and VEGF. The Cascade system concentrated leukocyte-poor PRP, compared with leukocyte-rich PRP from the GPS III and Magellan systems. The GPS III and Magellan concentrate leukocyte-rich PRP, which results in increased concentrations of WBCs, PDGF-αβ, PDGF-ββ, and VEGF as compared with the leukocyte-poor PRP from Cascade. Overall, there was no significant difference among systems in the platelet concentration, red blood cell, active TGF-β1, or fibrinogen levels. Products from commercially available PRP separation systems produce differing concentrations of growth factors and WBCs. Further research is necessary to determine the clinical relevance of these findings.
Artificial blood circulation: stabilization, physiological control, and optimization.
Lerner, A Y
1990-04-01
The requirements for creating an efficient Artificial Blood Circulation System (ABCS) have been determined. A hierarchical three-level adaptive control system is suggested for ABCS to solve the following problems: stabilization of the circulation conditions, left and right pump coordination, physiological control for maintaining a proper relation between the cardiac output and the level of gas exchange required for metabolism, and optimization of the system behavior. The adaptations to varying load and body parameters will be accomplished using the signals which characterize the real-time computer-processed values of correlations between the changes in hydraulic resistance of blood vessels, or the changes in aortic pressure, and the oxygen (or carbon dioxide) concentration.
[Blood transfusion and supply chain management safety].
Quaranta, Jean-François; Caldani, Cyril; Cabaud, Jean-Jacques; Chavarin, Patricia; Rochette-Eribon, Sandrine
2015-02-01
The level of safety attained in blood transfusion now makes this a discipline better managed care activities. This was achieved both by scientific advances and policy decisions regulating and supervising the activity, as well as by the quality system, which we recall that affects the entire organizational structure, responsibilities, procedures, processes and resources in place to achieve quality management. So, an effective quality system provides a framework within which activities are established, performed in a quality-focused way and continuously monitored to improve outcomes. This system quality has to irrigate all the actors of the transfusion, just as much the establishments of blood transfusion than the health establishments. Copyright © 2014 Elsevier Masson SAS. All rights reserved.
Computed aided system for separation and classification of the abnormal erythrocytes in human blood
NASA Astrophysics Data System (ADS)
Wąsowicz, Michał; Grochowski, Michał; Kulka, Marek; Mikołajczyk, Agnieszka; Ficek, Mateusz; Karpieńko, Katarzyna; Cićkiewicz, Maciej
2017-12-01
The human peripheral blood consists of cells (red cells, white cells, and platelets) suspended in plasma. In the following research the team assessed an influence of nanodiamond particles on blood elements over various periods of time. The material used in the study consisted of samples taken from ten healthy humans of various age, different blood types and both sexes. The markings were leaded by adding to the blood unmodified diamonds and oxidation modified. The blood was put under an impact of two diamond concentrations: 20μl and 100μl. The amount of abnormal cells increased with time. The percentage of echinocytes as a result of interaction with nanodiamonds in various time intervals for individual specimens was scarce. The impact of the two diamond types had no clinical importance on red blood cells. It is supposed that as a result of longlasting exposure a dehydratation of red cells takes place, because of the function of the cells. The analysis of an influence of nanodiamond particles on blood elements was supported by computer system designed for automatic counting and classification of the Red Blood Cells (RBC). The system utilizes advanced image processing methods for RBCs separation and counting and Eigenfaces method coupled with the neural networks for RBCs classification into normal and abnormal cells purposes.
Phan, Duc Tt; Bender, R Hugh F; Andrejecsk, Jillian W; Sobrino, Agua; Hachey, Stephanie J; George, Steven C; Hughes, Christopher Cw
2017-11-01
The blood-brain barrier is a dynamic and highly organized structure that strictly regulates the molecules allowed to cross the brain vasculature into the central nervous system. The blood-brain barrier pathology has been associated with a number of central nervous system diseases, including vascular malformations, stroke/vascular dementia, Alzheimer's disease, multiple sclerosis, and various neurological tumors including glioblastoma multiforme. There is a compelling need for representative models of this critical interface. Current research relies heavily on animal models (mostly mice) or on two-dimensional (2D) in vitro models, neither of which fully capture the complexities of the human blood-brain barrier. Physiological differences between humans and mice make translation to the clinic problematic, while monolayer cultures cannot capture the inherently three-dimensional (3D) nature of the blood-brain barrier, which includes close association of the abluminal side of the endothelium with astrocyte foot-processes and pericytes. Here we discuss the central nervous system diseases associated with blood-brain barrier pathology, recent advances in the development of novel 3D blood-brain barrier -on-a-chip systems that better mimic the physiological complexity and structure of human blood-brain barrier, and provide an outlook on how these blood-brain barrier-on-a-chip systems can be used for central nervous system disease modeling. Impact statement The field of microphysiological systems is rapidly evolving as new technologies are introduced and our understanding of organ physiology develops. In this review, we focus on Blood-Brain Barrier (BBB) models, with a particular emphasis on how they relate to neurological disorders such as Alzheimer's disease, multiple sclerosis, stroke, cancer, and vascular malformations. We emphasize the importance of capturing the three-dimensional nature of the brain and the unique architecture of the BBB - something that until recently had not been well modeled by in vitro systems. Our hope is that this review will provide a launch pad for new ideas and methodologies that can provide us with truly physiological BBB models capable of yielding new insights into the function of this critical interface.
Neural Control of the Cardiovascular System in Space
NASA Technical Reports Server (NTRS)
Levine, Benjamin D.; Pawelczyk, James A.; Zuckerman, Julie; Zhang, Rong; Fu, Qi; Iwasaki, Kenichi; Ray, Chet; Blomqvist, C. Gunnar; Lane, Lynda D.; Giller, Cole A.
2003-01-01
During the acute transition from lying supine to standing upright, a large volume of blood suddenly moves from the chest into the legs. To prevent fainting, the blood pressure control system senses this change immediately, and rapidly adjusts flow (by increasing heart rate) and resistance to flow (by constricting the blood vessels) to restore blood pressure and maintain brain blood flow. If this system is inadequate, the brain has a backup plan. Blood vessels in the brain can adjust their diameter to keep blood flow constant. If blood pressure drops, the brain blood vessels dilate; if blood pressure increases, the brain blood vessels constrict. This process, which is called autoregulation, allows the brain to maintain a steady stream of oxygen, even when blood pressure changes. We examined what changes in the blood pressure control system or cerebral autoregulation contribute to the blood pressure control problems seen after spaceflight. We asked: (1) does the adaptation to spaceflight cause an adaptation in the blood pressure control system that impairs the ability of the system to constrict blood vessels on return to Earth?; (2) if such a defect exists, could we pinpoint the neural pathways involved?; and (3) does cerebral autoregulation become abnormal during spaceflight, impairing the body s ability to maintain constant brain blood flow when standing upright on Earth? We stressed the blood pressure control system using lower body negative pressure, upright tilt, handgrip exercise, and cold stimulation of the hand. Standard cardiovascular parameters were measured along with sympathetic nerve activity (the nerve activity causing blood vessels to constrict) and brain blood flow. We confirmed that the primary cardiovascular effect of spaceflight was a postflight reduction in upright stroke volume (the amount of blood the heart pumps per beat). Heart rate increased appropriately for the reduction in stroke volume, thereby showing that changes in heart rate regulation alone cannot be responsible for orthostatic hypotension after spaceflight. All of the astronauts in our study had an increase in sympathetic nerve activity during upright tilting on Earth postflight. This increase was well calibrated for the reduction in stroke volume induced by the upright posture. The results obtained from stimulating the sympathetic nervous system using handgrip exercise or cold stress were also entirely normal during and after spaceflight. No astronaut had reduced cerebral blood flow during upright tilt, and cerebral autoregulation was normal or even enhanced inflight. These experiments show that the cardiovascular adaptation to spaceflight does not lead to a defect in the regulation of blood vessel constriction via sympathetic nerve activity. In addition, cerebral autoregulation is well-maintained. It is possible that despite the increased sympathetic nerve activity, blood vessels did not respond with a greater degree of constriction than occurred preflight, possibly uncovering a limit of vasoconstrictor reserve.
ISO 9000 quality standards: a model for blood banking?
Nevalainen, D E; Lloyd, H L
1995-06-01
The recent American Association of Blood Banks publications Quality Program and Quality Systems in the Blood Bank and Laboratory Environment, the FDA's draft guidelines, and recent changes in the GMP regulations all discuss the benefits of implementing quality systems in blood center and/or manufacturing operations. While the medical device GMPs in the United States have been rewritten to accommodate a quality system approach similar to ISO 9000, the Center for Biologics Evaluation and Research of the FDA is also beginning to make moves toward adopting "quality systems audits" as an inspection process rather than using the historical approach of record reviews. The approach is one of prevention of errors rather than detection after the fact (Tourault MA, oral communication, November 1994). The ISO 9000 series of standards is a quality system that has worldwide scope and can be applied in any industry or service. The use of such international standards in blood banking should raise the level of quality within an organization, among organizations on a regional level, within a country, and among nations on a worldwide basis. Whether an organization wishes to become registered to a voluntary standard or not, the use of such standards to become ISO 9000-compliant would be a move in the right direction and would be a positive sign to the regulatory authorities and the public that blood banking is making a visible effort to implement world-class quality systems in its operations. Implementation of quality system standards such as the ISO 9000 series will provide an organized approach for blood banks and blood bank testing operations. With the continued trend toward consolidation and mergers, resulting in larger operational units with more complexity, quality systems will become even more important as the industry moves into the future.(ABSTRACT TRUNCATED AT 250 WORDS)
NASA Astrophysics Data System (ADS)
Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian
2016-03-01
Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.
Multiscale systems biology of trauma-induced coagulopathy.
Tsiklidis, Evan; Sims, Carrie; Sinno, Talid; Diamond, Scott L
2018-07-01
Trauma with hypovolemic shock is an extreme pathological state that challenges the body to maintain blood pressure and oxygenation in the face of hemorrhagic blood loss. In conjunction with surgical actions and transfusion therapy, survival requires the patient's blood to maintain hemostasis to stop bleeding. The physics of the problem are multiscale: (a) the systemic circulation sets the global blood pressure in response to blood loss and resuscitation therapy, (b) local tissue perfusion is altered by localized vasoregulatory mechanisms and bleeding, and (c) altered blood and vessel biology resulting from the trauma as well as local hemodynamics control the assembly of clotting components at the site of injury. Building upon ongoing modeling efforts to simulate arterial or venous thrombosis in a diseased vasculature, computer simulation of trauma-induced coagulopathy is an emerging approach to understand patient risk and predict response. Despite uncertainties in quantifying the patient's dynamic injury burden, multiscale systems biology may help link blood biochemistry at the molecular level to multiorgan responses in the bleeding patient. As an important goal of systems modeling, establishing early metrics of a patient's high-dimensional trajectory may help guide transfusion therapy or warn of subsequent later stage bleeding or thrombotic risks. This article is categorized under: Analytical and Computational Methods > Computational Methods Biological Mechanisms > Regulatory Biology Models of Systems Properties and Processes > Mechanistic Models. © 2018 Wiley Periodicals, Inc.
SBR-Blood: systems biology repository for hematopoietic cells.
Lichtenberg, Jens; Heuston, Elisabeth F; Mishra, Tejaswini; Keller, Cheryl A; Hardison, Ross C; Bodine, David M
2016-01-04
Extensive research into hematopoiesis (the development of blood cells) over several decades has generated large sets of expression and epigenetic profiles in multiple human and mouse blood cell types. However, there is no single location to analyze how gene regulatory processes lead to different mature blood cells. We have developed a new database framework called hematopoietic Systems Biology Repository (SBR-Blood), available online at http://sbrblood.nhgri.nih.gov, which allows user-initiated analyses for cell type correlations or gene-specific behavior during differentiation using publicly available datasets for array- and sequencing-based platforms from mouse hematopoietic cells. SBR-Blood organizes information by both cell identity and by hematopoietic lineage. The validity and usability of SBR-Blood has been established through the reproduction of workflows relevant to expression data, DNA methylation, histone modifications and transcription factor occupancy profiles. Published by Oxford University Press on behalf of Nucleic Acids Research 2015. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Backscattering measuring system for optimization of intravenous laser irradiation dose
NASA Astrophysics Data System (ADS)
Rusina, Tatyana V.; Popov, V. D.; Melnik, Ivan S.; Dets, Sergiy M.
1996-11-01
Intravenous laser blood irradiation as an effective method of biostimulation and physiotherapy becomes a more popular procedure. Optimal irradiation conditions for each patient are needed to be established individually. A fiber optics feedback system combined with conventional intravenous laser irradiation system was developed to control of irradiation process. The system consists of He-Ne laser, fiber optics probe and signal analyzer. Intravenous blood irradiation was performed in 7 healthy volunteers and 19 patients with different diseases. Measurements in vivo were related to in vitro blood irradiation which was performed in the same conditions with force-circulated venous blood. Comparison of temporal variations of backscattered light during all irradiation procedures has shown a strong discrepancy on optical properties of blood in patients with various health disorders since second procedure. The best cure effect was achieved when intensity of backscattered light was constant during at least five minutes. As a result, the optical irradiation does was considered to be equal 20 minutes' exposure of 3 mW He-Ne laser light at the end of fourth procedure.
Microfluidic, marker-free isolation of circulating tumor cells from blood samples
Karabacak, Nezihi Murat; Spuhler, Philipp S; Fachin, Fabio; Lim, Eugene J; Pai, Vincent; Ozkumur, Emre; Martel, Joseph M; Kojic, Nikola; Smith, Kyle; Chen, Pin-i; Yang, Jennifer; Hwang, Henry; Morgan, Bailey; Trautwein, Julie; Barber, Thomas A; Stott, Shannon L; Maheswaran, Shyamala; Kapur, Ravi; Haber, Daniel A; Toner, Mehmet
2014-01-01
The ability to isolate and analyze rare circulating tumor cells (CTCs) has the potential to further our understanding of cancer metastasis and enhance the care of cancer patients. In this protocol, we describe the procedure for isolating rare CTCs from blood samples by using tumor antigen–independent microfluidic CTC-iChip technology. The CTC-iChip uses deterministic lateral displacement, inertial focusing and magnetophoresis to sort up to 107 cells/s. By using two-stage magnetophoresis and depletion antibodies against leukocytes, we achieve 3.8-log depletion of white blood cells and a 97% yield of rare cells with a sample processing rate of 8 ml of whole blood/h. The CTC-iChip is compatible with standard cytopathological and RNA-based characterization methods. This protocol describes device production, assembly, blood sample preparation, system setup and the CTC isolation process. Sorting 8 ml of blood sample requires 2 h including setup time, and chip production requires 2–5 d. PMID:24577360
Burtis, C.A.; Johnson, W.F.; Walker, W.A.
1985-08-05
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises: (1) a whole blood sample disc; (2) a serum sample disc; (3) a sample preparation rotor; and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analyticaly rotor for conventional methods. 5 figs.
Burtis, Carl A.; Johnson, Wayne F.; Walker, William A.
1988-01-01
A rotor and disc assembly for use in a centrifugal fast analyzer. The assembly is designed to process multiple samples of whole blood followed by aliquoting of the resultant serum into precisely measured samples for subsequent chemical analysis. The assembly requires minimal operator involvement with no mechanical pipetting. The system comprises (1) a whole blood sample disc, (2) a serum sample disc, (3) a sample preparation rotor, and (4) an analytical rotor. The blood sample disc and serum sample disc are designed with a plurality of precision bore capillary tubes arranged in a spoked array. Samples of blood are loaded into the blood sample disc in capillary tubes filled by capillary action and centrifugally discharged into cavities of the sample preparation rotor where separation of serum and solids is accomplished. The serum is loaded into the capillaries of the serum sample disc by capillary action and subsequently centrifugally expelled into cuvettes of the analytical rotor for analysis by conventional methods.
[Analysis of heat transfer in the biological tissue layer with distributed system of blood vessels].
Bogatov, N M; Pelipenko, O N
2005-09-01
Processes of heat transfer in the skin layer with blood vessels were investigated using mathematical modeling. Analysis of influence of a pathological state of blood vessels on heterogeneity of thermal field of the skin surface was carried out. For each site of body surface, there is a certain difference of temperature between normal and pathological sites, being specific for differential diagnosis of diseases of dermal and hypodermic vessels.
Pereira, Paulo; Westgard, James O; Encarnação, Pedro; Seghatchian, Jerard; de Sousa, Gracinda
2015-04-01
The screening laboratory has a critical role in the post-transfusion safety. The success of its targets and efficiency depends on the management system used. Even though the European Union directive 2002/98/EC requires a quality management system in blood establishments, its requirements for screening laboratories are generic. Complementary approaches are needed to implement a quality management system focused on screening laboratories. This article briefly discusses the current good manufacturing practices and good laboratory practices, as well as the trends in quality management system standards. ISO 9001 is widely accepted in some European Union blood establishments as the quality management standard, however this is not synonymous of its successful application. The ISO "risk-based thinking" is interrelated with the quality risk-management process of the EuBIS "Standards and criteria for the inspection of blood establishments". ISO 15189 should be the next step on the quality assurance of a screening laboratory, since it is focused on medical laboratory. To standardize the quality management systems in blood establishments' screening laboratories, new national and European claims focused on technical requirements following ISO 15189 is needed. Copyright © 2015 Elsevier Ltd. All rights reserved.
[Improvement and process optimization transfusion in Morocco: proposal of a new organization].
Bennis, I; Janah, S; Benajiba, M
2013-03-01
Propose a new organization for the Moroccan blood transfusion system. Through an analysis of several aspects of the current organization, both qualitatively and quantitatively (Statistics 2011), it was found that several failures of the current system prevent them from achieving it's objectives and ensuring its responsibilities. Using multiple-criteria decision analysis (ELECTRE III), a new organization based on resources pooling is proposed. This new organization concerns the status of the National Blood Transfusion Center, donor management, the geographical location of the various regional centers, logistics, inventory management and the information system. Within the new organization proposed, the number of regional Centers for blood transfusion is reduced from 16 to 7 in accordance with the existing constraints, while redefining the roles of each site. The aspects of inventory management, the information system, increasing the number of donors, the policy communication and marketing and cycle of blood collection and distribution are also redefined. This proposed new organization will provide decision makers with the necessary assistance for decision making, whit respect to the improvement of the entire system Moroccan blood transfusion system. And so help achieving the desired objectives on ensuring blood availability and it' maximum safety. The simulation of this proposal should confirm the choice that was made. Further analysis of complementary aspects such as the financial aspect or human resources, would moreover contribute to refining this proposal. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Manufacturing blood ex vivo: a futuristic approach to deal with the supply and safety concerns
Singh, Vimal K.; Saini, Abhishek; Tsuji, Kohichiro; Sharma, P. B.; Chandra, Ramesh
2014-01-01
Blood transfusions are routinely done in every medical regimen and a worldwide established collection, processing/storage centers provide their services for the same. There have been extreme global demands for both raising the current collections and supply of safe/adequate blood due to increasingly demanding population. With, various risks remain associated with the donor derived blood, and a number of post collection blood screening and processing methods put extreme constraints on supply system especially in the underdeveloped countries. A logistic approach to manufacture erythrocytes ex-vivo by using modern tissue culture techniques have surfaced in the past few years. There are several reports showing the possibilities of RBCs (and even platelets/neutrophils) expansion under tightly regulated conditions. In fact, ex vivo synthesis of the few units of clinical grade RBCs from a single dose of starting material such as umbilical cord blood (CB) has been well established. Similarly, many different sources are also being explored for the same purpose, such as embryonic stem cells, induced pluripotent stem cells. However, the major concerns remain elusive before the manufacture and clinical use of different blood components may be used to successfully replace the present system of donor derived blood transfusion. The most important factor shall include the large scale of RBCs production from each donated unit within a limited time period and cost of their production, both of these issues need to be handled carefully since many of the recipients among developing countries are unable to pay even for the freely available donor derived blood. Anyways, keeping these issues in mind, present article shall be focused on the possibilities of blood production and their use in the near future. PMID:25364733
Manufacturing blood ex vivo: a futuristic approach to deal with the supply and safety concerns.
Singh, Vimal K; Saini, Abhishek; Tsuji, Kohichiro; Sharma, P B; Chandra, Ramesh
2014-01-01
Blood transfusions are routinely done in every medical regimen and a worldwide established collection, processing/storage centers provide their services for the same. There have been extreme global demands for both raising the current collections and supply of safe/adequate blood due to increasingly demanding population. With, various risks remain associated with the donor derived blood, and a number of post collection blood screening and processing methods put extreme constraints on supply system especially in the underdeveloped countries. A logistic approach to manufacture erythrocytes ex-vivo by using modern tissue culture techniques have surfaced in the past few years. There are several reports showing the possibilities of RBCs (and even platelets/neutrophils) expansion under tightly regulated conditions. In fact, ex vivo synthesis of the few units of clinical grade RBCs from a single dose of starting material such as umbilical cord blood (CB) has been well established. Similarly, many different sources are also being explored for the same purpose, such as embryonic stem cells, induced pluripotent stem cells. However, the major concerns remain elusive before the manufacture and clinical use of different blood components may be used to successfully replace the present system of donor derived blood transfusion. The most important factor shall include the large scale of RBCs production from each donated unit within a limited time period and cost of their production, both of these issues need to be handled carefully since many of the recipients among developing countries are unable to pay even for the freely available donor derived blood. Anyways, keeping these issues in mind, present article shall be focused on the possibilities of blood production and their use in the near future.
Towards real-time medical diagnostics using hyperspectral imaging technology
NASA Astrophysics Data System (ADS)
Bjorgan, Asgeir; Randeberg, Lise L.
2015-07-01
Hyperspectral imaging provides non-contact, high resolution spectral images which has a substantial diagnostic potential. This can be used for e.g. diagnosis and early detection of arthritis in finger joints. Processing speed is currently a limitation for clinical use of the technique. A real-time system for analysis and visualization using GPU processing and threaded CPU processing is presented. Images showing blood oxygenation, blood volume fraction and vessel enhanced images are among the data calculated in real-time. This study shows the potential of real-time processing in this context. A combination of the processing modules will be used in detection of arthritic finger joints from hyperspectral reflectance and transmittance data.
Simultaneous measurement of time-domain fNIRS and physiological signals during a cognitive task
NASA Astrophysics Data System (ADS)
Jelzow, A.; Tachtsidis, I.; Kirilina, E.; Niessing, M.; Brühl, R.; Wabnitz, H.; Heine, A.; Ittermann, B.; Macdonald, R.
2011-07-01
Functional near-infrared spectroscopy (fNIRS) is a commonly used technique to measure the cerebral vascular response related to brain activation. It is known that systemic physiological processes, either independent or correlated with the stimulation task, can influence the optical signal making its interpretation challenging. The aim of the present work is to investigate the impact of task-evoked changes in the systemic physiology on fNIRS measurements for a cognitive paradigm. For this purpose we carried out simultaneous measurements of time-domain fNIRS on the forehead and systemic physiological signals, i.e. mean blood pressure, heart rate, respiration, galvanic skin response, scalp blood flow (flux) and red blood cell (RBC) concentration changes. We performed measurements on 15 healthy volunteers during a semantic continuous performance task (CPT). The optical data was analyzed in terms of depth-selective moments of distributions of times of flight of photons through the tissue. In addition, cerebral activation was localized by a subsequent fMRI experiment on the same subject population using the same task. We observed strong non-cerebral task-evoked changes in concentration changes of oxygenated hemoglobin in the forehead. We investigated the temporal behavior and mutual correlations between hemoglobin changes and the systemic processes. Mean blood pressure (BP), galvanic skin response (GSR) and heart rate exhibited significant changes during the activation period, whereby BP and GSR showed the highest correlation with optical measurements.
Dielectric coagulometry: a new approach to estimate venous thrombosis risk.
Hayashi, Yoshihito; Katsumoto, Yoichi; Omori, Shinji; Yasuda, Akio; Asami, Koji; Kaibara, Makoto; Uchimura, Isao
2010-12-01
We present dielectric coagulometry as a new technique to estimate the risk of venous thrombosis by measuring the permittivity change associated with the blood coagulation process. The method was first tested for a simple system of animal erythrocytes suspended in fibrinogen solution, where the coagulation rate was controlled by changing the amount of thrombin added to the suspension. Second, the method was applied to a more realistic system of human whole blood, and the inherent coagulation process was monitored without artificial acceleration by a coagulation initiator. The time dependence of the permittivity at a frequency around 1 MHz showed a distinct peak at a time that corresponds to the clotting time. Our theoretical modeling revealed that the evolution of heterogeneity and the sedimentation in the system cause the peak of the permittivity.
[Effect of vitamin C on the condition of NO-synthase system in experimental stomach ulcer].
Zhuroms'kyĭ, V S; Skliarov, O Ia
2011-01-01
We investigated the effect of Vitamin C (Vit C) on the changes of activity of the enzymes of NO-synthase system, nitric oxide content, lipoperoxidation processes, activity of SOD and catalase in gastric mucosa (GM), and concentrations of L-arginine, Vit C and Vit E in the blood of rats under conditions of experimental ulcer of the stomach caused by adrenaline injection. Vit C displayed a pronounced antioxidant action, reduced the degree of destructive affections, diminished the activity of iNOS and lipoperoxidation processes, decreased the NO content and SOD activity. Furthermore, the concentration of L-arginine and Vit C in the blood was increased. Combined action of Vit C with L-arginine reduced the degree of GM lesions, activity of eNOS and the content of NO in GM whereas the concentration of L-arginine in blood was increased. Under conditions of Vit C action and iNOS and COX-2 blockage, the activity of NO-synthases and lipoperoxidation processes were slightly decreased, indicating on dominant action of Vit C.
George, Elizabeth; Lai, Mei I; Teh, Lai Kuan; Ramasamy, Rajesh; Goh, Ern Huei; Asokan, Kamalan; Tan, J A M A; Vasudevan, Maithili; Low, Sharon
2011-12-01
Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.
Martusevich, A A; Martusevich, A K; Peretiagin, S P
2013-09-01
The aim of this work was the analysis of singlet oxygen and the ozone effect on lipid peroxidation and antioxidant activity of rat organs and blood. Wistar rats were randomly divided into five groups: control group (without any manipulations; n = 10) and four main groups (n = 10 in each group) with inhalations by dry, moisture and oil-processed ozone-oxygen mixture (ozone concentration 60 micro g/l) or singlet oxygen, respectively. Activity of pro- and antioxidant systems was estimated in blood and tissues (lungs, heart, liver and kidney) by inducing biochemiluminescence. Singlet oxygen was shown to exert the "mildest" effect with stimulation of blood antioxidant potential and saving tissue oxidative potential without hyperactivation of lipid peroxidation. Use of moistened ozone-oxygen mixture caused moderate stimulating action on antioxidant re serves of blood and tissues. Dry ozone-oxygen mixture clearly decreased lipid peroxidation intensity.
NASA Technical Reports Server (NTRS)
1986-01-01
Mallinckrodt Institute of Radiology (MIR) is using a digital image processing system which employs NASA-developed technology. MIR's computer system is the largest radiology system in the world. It is used in diagnostic imaging. Blood vessels are injected with x-ray dye, and the images which are produced indicate whether arteries are hardened or blocked. A computer program developed by Jet Propulsion Laboratory known as Mini-VICAR/IBIS was supplied to MIR by COSMIC. The program provides the basis for developing the computer imaging routines for data processing, contrast enhancement and picture display.
Evaluation of Membrane Systems for Washing/Deglycerolizing Packed Red Blood Cells
1987-03-20
d process should reduce the ss than 400 mOsm/kg H20 minutes. The plasma should be less than of centrifugal cessfully demonstrated the rane...2000 ml of wash solution in 35 to 45 minutes. The plasma hemoglobin (Hb) concentration in the washed RBCs should be less than 150 mg/dl. During...plasmapheresis, and the concentration of blood plasma applications, the membranes retain blood but remove water and paration that must be accomplished
Automatic tracking of labeled red blood cells in microchannels.
Pinho, Diana; Lima, Rui; Pereira, Ana I; Gayubo, Fernando
2013-09-01
The current study proposes an automatic method for the segmentation and tracking of red blood cells flowing through a 100- μm glass capillary. The original images were obtained by means of a confocal system and then processed in MATLAB using the Image Processing Toolbox. The measurements obtained with the proposed automatic method were compared with the results determined by a manual tracking method. The comparison was performed by using both linear regressions and Bland-Altman analysis. The results have shown a good agreement between the two methods. Therefore, the proposed automatic method is a powerful way to provide rapid and accurate measurements for in vitro blood experiments in microchannels. Copyright © 2012 John Wiley & Sons, Ltd.
Cip, Johannes; Widemschek, Mark; Benesch, Thomas; Waibel, Roman; Martin, Arno
2013-04-01
Mechanical autotransfusion systems for washed shed blood (WSB) were introduced to reduce the need for postoperative allogenic blood transfusions (ABTs). Although some authors have postulated decreased requirements for ABT by using autologous retransfusion devices, other trials, mostly evaluating retransfusion devices for unwashed shed blood (USB), verified a small or no benefit in reducing the need for postoperative ABT. Because of these contradictory findings it is still unclear whether autologous retransfusion systems for WSB can reduce transfusion requirements. We therefore asked whether one such autologous transfusion system for WSB can reduce the requirements for postoperative ABT. In a prospective, randomized, controlled study, we enrolled 151 patients undergoing TKA. In Group A (n=76 patients), the autotransfusion system was used for a total of 6 hours (intraoperatively and postoperatively) and the WSB was retransfused after processing. In Control Group B (n=75 patients), a regular drain without suction was used. We used signs of anemia and/or a hemoglobin value less than 8 g/dL as indications for transfusion. If necessary, we administered one or two units of allogenic blood. Twenty-three patients (33%) in Group A, who received an average of 283 mL (range, 160-406 mL) of salvaged blood, needed a mean of 2.1 units of allogenic blood, compared with 23 patients (33%) in Control Group B who needed a mean of 2.1 units of allogenic blood. We found the use of an autotransfusion system did not reduce the rate of postoperative ABTs. Level II, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Hoek, Kristen L; Samir, Parimal; Howard, Leigh M; Niu, Xinnan; Prasad, Nripesh; Galassie, Allison; Liu, Qi; Allos, Tara M; Floyd, Kyle A; Guo, Yan; Shyr, Yu; Levy, Shawn E; Joyce, Sebastian; Edwards, Kathryn M; Link, Andrew J
2015-01-01
Systems biology is an approach to comprehensively study complex interactions within a biological system. Most published systems vaccinology studies have utilized whole blood or peripheral blood mononuclear cells (PBMC) to monitor the immune response after vaccination. Because human blood is comprised of multiple hematopoietic cell types, the potential for masking responses of under-represented cell populations is increased when analyzing whole blood or PBMC. To investigate the contribution of individual cell types to the immune response after vaccination, we established a rapid and efficient method to purify human T and B cells, natural killer (NK) cells, myeloid dendritic cells (mDC), monocytes, and neutrophils from fresh venous blood. Purified cells were fractionated and processed in a single day. RNA-Seq and quantitative shotgun proteomics were performed to determine expression profiles for each cell type prior to and after inactivated seasonal influenza vaccination. Our results show that transcriptomic and proteomic profiles generated from purified immune cells differ significantly from PBMC. Differential expression analysis for each immune cell type also shows unique transcriptomic and proteomic expression profiles as well as changing biological networks at early time points after vaccination. This cell type-specific information provides a more comprehensive approach to monitor vaccine responses.
Tsang, Hamilton C; Garcia, Adam; Scott, Robert; Lancaster, David; Geary, Dianne; Nguyen, Anh-Thu; Shankar, Raina; Buchanan, Leslie; Pham, Tho D
2018-05-16
The ordering process at Stanford Health Care involved twice-daily shipments predicated upon current stock levels from the blood center to the hospital transfusion service. Manual census determination is time consuming and error prone. We aimed to enhance inventory management by developing an informatics platform to streamline the ordering process and reallocate staff productivity. The general inventory accounts for more than 50 product categories based on characteristics including component, blood type, irradiation status, and cytomegalovirus serology status. Over a 5-month calibration period, inventory levels were determined algorithmically and electronically. An in-house software program was created to determine inventory levels, optimize the electronic ordering process, and reduce labor time. A 3-month pilot period was implemented using this program. This system showed noninferiority while saving labor time. The average weekly transfused:stocked ratios for cryoprecipitate, plasma, and red blood cells, respectively, were 1.03, 1.21, and 1.48 before the pilot period, compared with 0.88, 1.17, and 1.40 during (p = 0.28). There were 27 (before) and 31 (during) average STAT units ordered per week (p = 0.86). The number of monthly wasted products due to expiration was 226 (before) and 196 (during) units, respectively (p = 0.28). An estimated 7 hours per week of technologist time was reallocated to other tasks. An in-house electronic ordering system can enhance information fidelity, reallocate and optimize valuable staff productivity, and further standardize ordering. This system showed noninferiority to the labor-intensive manual system while freeing up over 360 hours of staff time per year. © 2018 AABB.
Dynamical Analysis in the Mathematical Modelling of Human Blood Glucose
ERIC Educational Resources Information Center
Bae, Saebyok; Kang, Byungmin
2012-01-01
We want to apply the geometrical method to a dynamical system of human blood glucose. Due to the educational importance of model building, we show a relatively general modelling process using observational facts. Next, two models of some concrete forms are analysed in the phase plane by means of linear stability, phase portrait and vector…
Zbrun, M V; Frizzo, L S; Soto, L P; Rosmini, M R; Sequeira, G J; Astesana, D M; Blajman, J E; Rossler, E; Berisvil, A; Romero Scharpen, A; Signorini, M L
2016-10-01
The aim of this study was to investigate the use of indigenous lactic acid bacteria (LAB) with specific additives as a Biopreservation System (BS) for poultry blood during its storage in slaughterhouses. The BS consisted of two LAB (Enterococcus faecalis DSPV 008SA or Lactobacillus salivarius DSPV 032SA) with 4 additives (lactose 2 g/l, yeast extract 0.4 g/l, ammonium citrate 0.4 g/l and NaCl 1 g/l). After 24 h storage at 30ºC, lower counts of enterobacteria, coliforms, Pseudomonas spp. and Staphylococcus aureus were evident in blood treated with the BS than in untreated blood. The ability of LAB to prevent haemolysis was evident. A decrease in pH was associated with control of spoilage microorganisms but it needed to be regulated to prevent coagulation of proteins. On the basis of these results it is recommended to supplement blood with a BS to avoid undesirable changes during blood storage before processing.
Neurotoxicology of the Brain Barrier System: New Implications
Zheng, Wei
2014-01-01
The concept of a barrier system in the brain has existed for nearly a century. The barrier that separates the blood from the cerebral interstitial fluid is defined as the blood-brain barrier, while the one that discontinues the circulation between the blood and cerebrospinal fluid is named the blood-cerebrospinal fluid barrier. Evidence in the past decades suggests that brain barriers are subject to toxic insults from neurotoxic chemicals circulating in blood. The aging process and some disease states render barriers more vulnerable to insults arising inside and outside the barriers. The implication of brain barriers in certain neurodegenerative diseases is compelling, although the contribution of chemical-induced barrier dysfunction in the etiology of any of these disorders remains poorly understood. This review examines what is currently understood about brain barrier systems in central nervous system disorders by focusing on chemical-induced neurotoxicities including those associated with nitrobenzenes, N-methyl-D-aspartate, cyclosporin A, pyridostigmine bromide, aluminum, lead, manganese, 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine, and 3-nitropropionic acid. Contemporary research questions arising from this growing understanding show enormous promises for brain researchers, toxicologists, and clinicians. PMID:11778669
The meningeal lymphatic system: a route for HIV brain migration?
Lamers, Susanna L; Rose, Rebecca; Ndhlovu, Lishomwa C; Nolan, David J; Salemi, Marco; Maidji, Ekaterina; Stoddart, Cheryl A; McGrath, Michael S
2016-06-01
Two innovative studies recently identified functional lymphatic structures in the meninges that may influence the development of HIV-associated neurological disorders (HAND). Until now, blood vessels were assumed to be the sole transport system by which HIV-infected monocytes entered the brain by bypassing a potentially hostile blood-brain barrier through inflammatory-mediated semi-permeability. A cascade of specific chemokine signals promote monocyte migration from blood vessels to surrounding brain tissues via a well-supported endothelium, where the cells differentiate into tissue macrophages capable of productive HIV infection. Lymphatic vessels on the other hand are more loosely organized than blood vessels. They absorb interstitial fluid from bodily tissues where HIV may persist and exchange a variety of immune cells (CD4(+) T cells, monocytes, macrophages, and dendritic cells) with surrounding tissues through discontinuous endothelial junctions. We propose that the newly discovered meningeal lymphatics are key to HIV migration among viral reservoirs and brain tissue during periods of undetectable plasma viral loads due to suppressive combinational antiretroviral therapy, thus redefining the migration process in terms of a blood-lymphatic transport system.
Total quality management in blood transfusion.
Smit-Sibinga, C T
2000-01-01
Quality management is an ongoing development resulting in consistency products and services and ever increasing customer satisfaction. The ultimum is Total Quality Management. Quality systems and quality management in transfusion medicine have gained considerable attention since the outbreak of the AIDS epidemic. Where product orientation has long been applied through quality control, Good Manufacturing Practice (GMP) principles were introduced, shifting the developments in the direction of process orientation. Globally, and particularly in the more industrialised world people and system orientation has come along with the introduction of the ISO9001 concept. Harmonisation and a degree of uniformity are needed to implement a universally applicable Quality System and related Quality Management. Where the American Association of Blood Banks (AABB) is the professional organisation with the most extensive experience in quality systems in blood transfusion, the European Union and the Council of Europe now are in the process to design a quality system and management applicable to a larger variety of countries, based on a hybrid of current GMP and ISO9001 principles. The International Federation of Red Cross and Red Crescent Societies has developed a more universally to implement Quality Manual, with a pilot project in Honduras. It is recommendable to harmonise the various designs and bring the approaches under one common denominator.
Social Support and Heart Failure: Differing Effects by Race
2015-05-11
responses. These compensatory physiologic responses include increased sympathetic nervous system activity, inflammation, and constriction of blood vessels... physiological differences between African Americans and Caucasians. For instance the process by which sodium is processed in the body may vary between...associated cardiovascular and inflammatory diseases (76). One important hormone at work in the cardiovascular system is aldosterone and it may have a
Goldman, Mindy; Núria, Núria; Castilho, Lilian M
2015-01-01
Automated testing platforms facilitate the introduction of red cell genotyping of patients and blood donors. Fluidic microarray systems, such as Luminex XMAP (Austin, TX), are used in many clinical applications, including HLA and HPA typing. The Progenika ID CORE XT (Progenika Biopharma-Grifols, Bizkaia, Spain) uses this platform to analyze 29 polymorphisms determining 37 antigens in 10 blood group systems. Once DNA has been extracted, processing time is approximately 4 hours. The system is highly automated and includes integrated analysis software that produces a file and a report with genotype and predicted phenotype results.
Assessment of Normal Variability in Peripheral Blood Gene Expression
Campbell, Catherine; Vernon, Suzanne D.; Karem, Kevin L.; ...
2002-01-01
Peripheral blood is representative of many systemic processes and is an ideal sample for expression profiling of diseases that have no known or accessible lesion. Peripheral blood is a complex mixture of cell types and some differences in peripheral blood gene expression may reflect the timing of sample collection rather than an underlying disease process. For this reason, it is important to assess study design factors that may cause variability in gene expression not related to what is being analyzed. Variation in the gene expression of circulating peripheral blood mononuclear cells (PBMCs) from three healthy volunteers sampled three times onemore » day each week for one month was examined for 1,176 genes printed on filter arrays. Less than 1% of the genes showed any variation in expression that was related to the time of collection, and none of the changes were noted in more than one individual. These results suggest that observed variation was due to experimental variability.« less
Classical Renin-Angiotensin System in Kidney Physiology
Sparks, Matthew A.; Crowley, Steven D.; Gurley, Susan B.; Mirotsou, Maria; Coffman, Thomas M.
2014-01-01
The renin-angiotensin system has powerful effects in control of the blood pressure and sodium homeostasis. These actions are coordinated through integrated actions in the kidney, cardio-vascular system and the central nervous system. Along with its impact on blood pressure, the renin-angiotensin system also influences a range of processes from inflammation and immune responses to longevity. Here, we review the actions of the “classical” renin-angiotensin system, whereby the substrate protein angiotensinogen is processed in a two-step reaction by renin and angiotensin converting enzyme, resulting in the sequential generation of angiotensin I and angiotensin II, the major biologically active renin-angiotensin system peptide, which exerts its actions via type 1 and type 2 angiotensin receptors. In recent years, several new enzymes, peptides, and receptors related to the renin-angiotensin system have been identified, manifesting a complexity that was previously unappreciated. While the functions of these alternative pathways will be reviewed elsewhere in this journal, our focus here is on the physiological role of components of the “classical” renin-angiotensin system, with an emphasis on new developments and modern concepts. PMID:24944035
Valletta, John Joseph; Chipperfield, Andrew J; Byrne, Christopher D
2009-01-01
Good blood glucose control is important to people with type 1 diabetes to prevent diabetes-related complications. Too much blood glucose (hyperglycaemia) causes long-term micro-vascular complications, while a severe drop in blood glucose (hypoglycaemia) can cause life-threatening coma. Finding the right balance between quantity and type of food intake, physical activity levels and insulin dosage, is a daily challenge. Increased physical activity levels often cause changes in blood glucose due to increased glucose uptake into tissues such as muscle. To date we have limited knowledge about the minute by minute effects of exercise on blood glucose levels, in part due to the difficulty in measuring glucose and physical activity levels continuously, in a free-living environment. By using a light and user-friendly armband we can record physical activity energy expenditure on a minute-by-minute basis. Simultaneously, by using a continuous glucose monitoring system we can record glucose concentrations. In this paper, Gaussian Processes are used to model the glucose excursions in response to physical activity data, to study its effect on glycaemic control.
Secomb, Timothy W.
2016-01-01
A review is presented of the physical principles governing the distribution of blood flow and blood pressure in the vascular system. The main factors involved are the pulsatile driving pressure generated by the heart, the flow characteristics of blood, and the geometric structure and mechanical properties of the vessels. The relationship between driving pressure and flow in a given vessel can be understood by considering the viscous and inertial forces acting on the blood. Depending on the vessel diameter and other physical parameters, a wide variety of flow phenomena can occur. In large arteries, the propagation of the pressure pulse depends on the elastic properties of the artery walls. In the microcirculation, the fact that blood is a suspension of cells strongly influences its flow properties and leads to a non-uniform distribution of hematocrit among microvessels. The forces acting on vessel walls include shear stress resulting from blood flow and circumferential stress resulting from blood pressure. Biological responses to these forces are important in the control of blood flow and the structural remodeling of vessels, and also play a role in major disease processes including hypertension and atherosclerosis. Consideration of hemodynamics is essential for a comprehensive understanding of the functioning of the circulatory system. PMID:27065172
Russom, Diana; Ahmed, Amira; Gonzalez, Nancy; Alvarnas, Joseph; DiGiusto, David
2012-01-01
Regulatory requirements for the manufacturing of cell products for clinical investigation require a significant level of record-keeping, starting early in process development and continuing through to the execution and requisite follow-up of patients on clinical trials. Central to record-keeping is the management of documentation related to patients, raw materials, processes, assays and facilities. To support these requirements, we evaluated several laboratory information management systems (LIMS), including their cost, flexibility, regulatory compliance, ongoing programming requirements and ability to integrate with laboratory equipment. After selecting a system, we performed a pilot study to develop a user-configurable LIMS for our laboratory in support of our pre-clinical and clinical cell-production activities. We report here on the design and utilization of this system to manage accrual with a healthy blood-donor protocol, as well as manufacturing operations for the production of a master cell bank and several patient-specific stem cell products. The system was used successfully to manage blood donor eligibility, recruiting, appointments, billing and serology, and to provide annual accrual reports. Quality management reporting features of the system were used to capture, report and investigate process and equipment deviations that occurred during the production of a master cell bank and patient products. Overall the system has served to support the compliance requirements of process development and phase I/II clinical trial activities for our laboratory and can be easily modified to meet the needs of similar laboratories.
On-chip wavelength multiplexed detection of cancer DNA biomarkers in blood
Cai, H.; Stott, M. A.; Ozcelik, D.; Parks, J. W.; Hawkins, A. R.; Schmidt, H.
2016-01-01
We have developed an optofluidic analysis system that processes biomolecular samples starting from whole blood and then analyzes and identifies multiple targets on a silicon-based molecular detection platform. We demonstrate blood filtration, sample extraction, target enrichment, and fluorescent labeling using programmable microfluidic circuits. We detect and identify multiple targets using a spectral multiplexing technique based on wavelength-dependent multi-spot excitation on an antiresonant reflecting optical waveguide chip. Specifically, we extract two types of melanoma biomarkers, mutated cell-free nucleic acids —BRAFV600E and NRAS, from whole blood. We detect and identify these two targets simultaneously using the spectral multiplexing approach with up to a 96% success rate. These results point the way toward a full front-to-back chip-based optofluidic compact system for high-performance analysis of complex biological samples. PMID:28058082
Image processing and machine learning in the morphological analysis of blood cells.
Rodellar, J; Alférez, S; Acevedo, A; Molina, A; Merino, A
2018-05-01
This review focuses on how image processing and machine learning can be useful for the morphological characterization and automatic recognition of cell images captured from peripheral blood smears. The basics of the 3 core elements (segmentation, quantitative features, and classification) are outlined, and recent literature is discussed. Although red blood cells are a significant part of this context, this study focuses on malignant lymphoid cells and blast cells. There is no doubt that these technologies may help the cytologist to perform efficient, objective, and fast morphological analysis of blood cells. They may also help in the interpretation of some morphological features and may serve as learning and survey tools. Although research is still needed, it is important to define screening strategies to exploit the potential of image-based automatic recognition systems integrated in the daily routine of laboratories along with other analysis methodologies. © 2018 John Wiley & Sons Ltd.
Monte-Moreno, Enric
2011-10-01
This work presents a system for a simultaneous non-invasive estimate of the blood glucose level (BGL) and the systolic (SBP) and diastolic (DBP) blood pressure, using a photoplethysmograph (PPG) and machine learning techniques. The method is independent of the person whose values are being measured and does not need calibration over time or subjects. The architecture of the system consists of a photoplethysmograph sensor, an activity detection module, a signal processing module that extracts features from the PPG waveform, and a machine learning algorithm that estimates the SBP, DBP and BGL values. The idea that underlies the system is that there is functional relationship between the shape of the PPG waveform and the blood pressure and glucose levels. As described in this paper we tested this method on 410 individuals without performing any personalized calibration. The results were computed after cross validation. The machine learning techniques tested were: ridge linear regression, a multilayer perceptron neural network, support vector machines and random forests. The best results were obtained with the random forest technique. In the case of blood pressure, the resulting coefficients of determination for reference vs. prediction were R(SBP)(2)=0.91, R(DBP)(2)=0.89, and R(BGL)(2)=0.90. For the glucose estimation, distribution of the points on a Clarke error grid placed 87.7% of points in zone A, 10.3% in zone B, and 1.9% in zone D. Blood pressure values complied with the grade B protocol of the British Hypertension society. An effective system for estimate of blood glucose and blood pressure from a photoplethysmograph is presented. The main advantage of the system is that for clinical use it complies with the grade B protocol of the British Hypertension society for the blood pressure and only in 1.9% of the cases did not detect hypoglycemia or hyperglycemia. Copyright © 2011 Elsevier B.V. All rights reserved.
Fricano, Meagan M; Ditewig, Amy C; Jung, Paul M; Liguori, Michael J; Blomme, Eric A G; Yang, Yi
2011-01-01
Blood is an ideal tissue for the identification of novel genomic biomarkers for toxicity or efficacy. However, using blood for transcriptomic profiling presents significant technical challenges due to the transcriptomic changes induced by ex vivo handling and the interference of highly abundant globin mRNA. Most whole blood RNA stabilization and isolation methods also require significant volumes of blood, limiting their effective use in small animal species, such as rodents. To overcome these challenges, a QIAzol-based RNA stabilization and isolation method (QSI) was developed to isolate sufficient amounts of high quality total RNA from 25 to 500 μL of rat whole blood. The method was compared to the standard PAXgene Blood RNA System using blood collected from rats exposed to saline or lipopolysaccharide (LPS). The QSI method yielded an average of 54 ng total RNA per μL of rat whole blood with an average RNA Integrity Number (RIN) of 9, a performance comparable with the standard PAXgene method. Total RNA samples were further processed using the NuGEN Ovation Whole Blood Solution system and cDNA was hybridized to Affymetrix Rat Genome 230 2.0 Arrays. The microarray QC parameters using RNA isolated with the QSI method were within the acceptable range for microarray analysis. The transcriptomic profiles were highly correlated with those using RNA isolated with the PAXgene method and were consistent with expected LPS-induced inflammatory responses. The present study demonstrated that the QSI method coupled with NuGEN Ovation Whole Blood Solution system is cost-effective and particularly suitable for transcriptomic profiling of minimal volumes of whole blood, typical of those obtained with small animal species.
Remote Blood Glucose Monitoring in mHealth Scenarios: A Review.
Lanzola, Giordano; Losiouk, Eleonora; Del Favero, Simone; Facchinetti, Andrea; Galderisi, Alfonso; Quaglini, Silvana; Magni, Lalo; Cobelli, Claudio
2016-11-24
Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient's significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators.
Remote Blood Glucose Monitoring in mHealth Scenarios: A Review
Lanzola, Giordano; Losiouk, Eleonora; Del Favero, Simone; Facchinetti, Andrea; Galderisi, Alfonso; Quaglini, Silvana; Magni, Lalo; Cobelli, Claudio
2016-01-01
Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient’s significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators. PMID:27886122
Chaszczewska-Markowska, Monika; Sagan, Maria; Bogunia-Kubik, Katarzyna
2016-09-13
Secretion of renin juxtaglomerular cells into bloodstream initiates activation of an enzymatic-hormonal cascade known as the RAAS (renin - angiotensin - aldosterone system). As a result, blood pressure is increased by the means several interrelated mechanisms. Mechanism of Zjednoczoaction of this system has been known for decades, but a few previously unknown components were recently added, such as ACE-2 and Ang(1-7), and their role often seems to be opposite to that of the conventional components. Local tissue systems also have important biological functions. They operate largely independently of the systemic activity, and their activity is observed primarily in the kidney, heart, in blood vessels, adrenal gland and nervous system. Angiotensin-2 (Ang-2), the main RAAS effector, has a wide scope of action, and thus abnormalities in its functioning have many consequences. Excessive activation is accompanied by chronic inflammation, as Ang-2 stimulates inflammatory mediators. As a result, degenerative processes and atherosclerosis are initiated. RAAS imbalance is associated with the most common diseases of civilization, such as cardio-vascular diseases, diabetes, kidney diseases, preeclampsia, osteoporosis and even neurodegenerative diseases. Many of these pathological processes are attributed to the excessive activation of tissue RA system. Therapeutic strategies based on inhibition of the RAAS are commonly used mainly in the treatment of hypertension and other cardiovascular disorders. The benefits of this class of drugs is primarily a decrease in blood pressure, but also the suppression of inflammatory processes and other pathological phenomena resulting from excessive activation of the RAAS. For that reason, some consider to use RAAS inhibitors in other diseases, e.g. Parkinson's disease. Further studies give hope for the improvement of RAAS inhibitor therapy and the development of new therapeutic strategies.
Validity of a portable glucose, total cholesterol, and triglycerides multi-analyzer in adults.
Coqueiro, Raildo da Silva; Santos, Mateus Carmo; Neto, João de Souza Leal; Queiroz, Bruno Morbeck de; Brügger, Nelson Augusto Jardim; Barbosa, Aline Rodrigues
2014-07-01
This study investigated the accuracy and precision of the Accutrend Plus system to determine blood glucose, total cholesterol, and plasma triglycerides in adults and evaluated its efficiency in measuring these blood variables. The sample consisted of 53 subjects (≥ 18 years). For blood variable laboratory determination, venous blood samples were collected and processed in a Labmax 240 analyzer. To measure blood variables with the Accutrend Plus system, samples of capillary blood were collected. In the analysis, the following tests were included: Wilcoxon and Student's t-tests for paired samples, Lin's concordance coefficient, Bland-Altman method, receiver operating characteristic curve, McNemar test, and k statistics. The results show that the Accutrend Plus system provided significantly higher values (p ≤ .05) of glucose and triglycerides but not of total cholesterol (p > .05) as compared to the values determined in the laboratory. However, the system showed good reproducibility (Lin's coefficient: glucose = .958, triglycerides = .992, total cholesterol = .940) and high concordance with the laboratory method (Lin's coefficient: glucose = .952, triglycerides = .990, total cholesterol = .944) and high sensitivity (glucose = 80.0%, triglycerides = 90.5%, total cholesterol = 84.4%) and specificity (glucose = 100.0%, triglycerides = 96.9%, total cholesterol = 95.2%) in the discrimination of high values of the three blood variables analyzed. It could be concluded that despite the tendency to overestimate glucose and triglyceride levels, a portable multi-analyzer is a valid alternative for the monitoring of metabolic disorders and cardiovascular risk factors. © The Author(s) 2013.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weinstein, M.P.; Mirrett, S.; Reimer, L.G.
1989-03-01
In an initial evaluation, we found the Oxoid Signal blood culture system inferior to the BACTEC radiometric system for detection of some microorganisms causing septicemia. To determine whether modified processing of the Oxoid Signal blood culture system could improve its yield and speed of detecting positive cultures relative to the BACTEC radiometric system, we agitated all Oxoid bottles during the first 24 to 48 h of incubation and performed aerobic and anaerobic subcultures of all Oxoid bottles negative after 7 days of incubation. These modifications improved the overall performance of the Oxoid system, particularly with regard to the yield ofmore » streptococci, members of the family Enterobacteriaceae, and Haemophilus, Neisseria, and Acinetobacter spp. The speed of detecting positive cultures also was improved, especially within the first 24 h of incubation. However, the BACTEC system still detected more positive cultures (P less than 0.005), especially of obligate aerobes such as Pseudomonas aeruginosa (P less than 0.05) and yeasts (P less than 0.005). The BACTEC system also detected positive cultures earlier than the Oxoid system (e.g., at 24 h of incubation, 70.5% of BACTEC positive cultures detected versus 62.1% of Oxoid positive cultures detected). Further modifications of the Oxoid system which might include a revised medium, additional processing modifications, altered headspace atmosphere, or a complementary second broth medium should be considered, since the system is attractive in concept and is easy to use in the clinical laboratory.« less
Arithmetic of five-part of leukocytes based on image process
NASA Astrophysics Data System (ADS)
Li, Yian; Wang, Guoyou; Liu, Jianguo
2007-12-01
This paper apply computer image processing and pattern recognizition methods to solve the problem of auto classification and counting of leukocytes (white blood cell) in peripheral blood. In this paper a new leukocyte arithmetic of five-part based on image process and pattern recognizition is presented, which relized auto classify of leukocyte. The first aim is detect the leukocytes . A major requirement of the whole system is to classify these leukocytes to 5 classes. This arithmetic bases on notability mechanism of eyes, process image by sequence, divides up leukocytes and pick up characters. Using the prior kwonledge of cells and image shape information, this arithmetic divides up the probable shape of Leukocyte first by a new method based on Chamfer and then gets the detail characters. It can reduce the mistake judge rate and the calculation greatly. It also has the learning fuction. This paper also presented a new measurement of karyon's shape which can provide more accurate information. This algorithm has great application value in clinical blood test .
Frank, Steven M; Rothschild, James A; Masear, Courtney G; Rivers, Richard J; Merritt, William T; Savage, Will J; Ness, Paul M
2013-06-01
The maximum surgical blood order schedule (MSBOS) is used to determine preoperative blood orders for specific surgical procedures. Because the list was developed in the late 1970s, many new surgical procedures have been introduced and others improved upon, making the original MSBOS obsolete. The authors describe methods to create an updated, institution-specific MSBOS to guide preoperative blood ordering. Blood utilization data for 53,526 patients undergoing 1,632 different surgical procedures were gathered from an anesthesia information management system. A novel algorithm based on previously defined criteria was used to create an MSBOS for each surgical specialty. The economic implications were calculated based on the number of blood orders placed, but not indicated, according to the MSBOS. Among 27,825 surgical cases that did not require preoperative blood orders as determined by the MSBOS, 9,099 (32.7%) had a type and screen, and 2,643 (9.5%) had a crossmatch ordered. Of 4,644 cases determined to require only a type and screen, 1,509 (32.5%) had a type and crossmatch ordered. By using the MSBOS to eliminate unnecessary blood orders, the authors calculated a potential reduction in hospital charges and actual costs of $211,448 and $43,135 per year, respectively, or $8.89 and $1.81 per surgical patient, respectively. An institution-specific MSBOS can be created, using blood utilization data extracted from an anesthesia information management system along with our proposed algorithm. Using these methods to optimize the process of preoperative blood ordering can potentially improve operating room efficiency, increase patient safety, and decrease costs.
NASA Astrophysics Data System (ADS)
Wróbel, M. S.; Gnyba, M.; Milewska, D.; Mitura, K.; Karpienko, K.
2015-09-01
A dedicated absorption spectroscopy system was set up using tungsten-halogen broadband source, optical fibers, sample holder, and a commercial spectrometer with CCD array. Analysis of noise present in the setup was carried out. Data processing was applied to the absorption spectra to reduce spectral noise, and improve the quality of the spectra and to remove the baseline level. The absorption spectra were measured for whole blood samples, separated components: plasma, saline, washed erythrocytes in saline and human whole blood with biomarkers - biocompatible nanodiamonds (ND). Blood samples had been derived from a number of healthy donors. The results prove a correct setup arrangement, with adequate preprocessing of the data. The results of blood-ND mixtures measurements show no toxic effect on blood cells, which proves the NDs as a potential biocompatible biomarkers.
High-speed video capillaroscopy method for imaging and evaluation of moving red blood cells
NASA Astrophysics Data System (ADS)
Gurov, Igor; Volkov, Mikhail; Margaryants, Nikita; Pimenov, Aleksei; Potemkin, Andrey
2018-05-01
The video capillaroscopy system with high image recording rate to resolve moving red blood cells with velocity up to 5 mm/s into a capillary is considered. Proposed procedures of the recorded video sequence processing allow evaluating spatial capillary area, capillary diameter and central line with high accuracy and reliability independently on properties of individual capillary. Two-dimensional inter frame procedure is applied to find lateral shift of neighbor images in the blood flow area with moving red blood cells and to measure directly the blood flow velocity along a capillary central line. The developed method opens new opportunities for biomedical diagnostics, particularly, due to long-time continuous monitoring of red blood cells velocity into capillary. Spatio-temporal representation of capillary blood flow is considered. Experimental results of direct measurement of blood flow velocity into separate capillary as well as capillary net are presented and discussed.
Effect of Processing and Storage on RBC function in vivo
Doctor, Allan; Spinella, Phil
2012-01-01
Red Blood Cell (RBC) transfusion is indicated to improve oxygen delivery to tissue, and for no other purpose. We have come to appreciate that donor RBCs are fundamentally altered during processing and storage, in a fashion that both impairs oxygen transport efficacy and introduces additional risk by perturbing both immune and coagulation systems. The protean biophysical and physiologic changes in RBC function arising from storage are termed the ‘storage lesion’; many have been understood for some time; for example, we know that the oxygen affinity of stored blood rises during the storage period1 and that intracellular allosteric regulators, notably 2,3-bisphosphoglyceric acid (DPG) and ATP, are depleted during storage. Our appreciation of other storage lesion features has emerged with improved understanding of coagulation, immune and vascular signaling systems. Herein we review key features of the ‘storage lesion’. Additionally, we call particular attention to the newly appreciated role of RBCs in regulating linkage between regional blood flow and regional O2 consumption by regulating the bioavailability of key vasoactive mediators in plasma, as well as discuss how processing and storage disturbs this key signaling function and impairs transfusion efficacy. PMID:22818545
Bauer, Adrian; Hausmann, Harald; Schaarschmidt, Jan; Scharpenberg, Martin; Troitzsch, Dirk; Johansen, Peter; Nygaard, Hans; Eberle, Thomas; Hasenkam, J Michael
2018-03-01
The postoperative systemic inflammatory response after cardiopulmonary bypass (CPB) is still an undesirable side-effect after cardiac surgery. It is most likely caused by blood contact with foreign surfaces and by the surgical trauma itself. However, the recirculation of activated shed mediastinal blood is another main cause of blood cell activation and cytokine release. Minimal invasive extracorporeal circulation (MiECC) comprises a completely closed circuit, coated surfaces and the separation of suction blood. We hypothesized that MiECC, with separated cell saved blood, would induce less of a systemic inflammatory response than MiECC with no cell-saver. The aim of this study was, therefore, to investigate the impact of cell washing shed blood from the operating field versus direct return to the ECC on the biomarkers for systemic inflammation. In the study, patients with MiECC and cell-saver were compared with the control group, patients with MiECC and direct re-transfusion of the drawn blood shed from the surgical field. High amounts of TNF-α (+ 120% compared to serum blood) were found in the shed blood itself, but a significant reduction was demonstrated with the use of a cell-saver (TNF-α ng/l post-ECC 10 min: 9.5±3.5 vs. 19.7±14.5, p<0.0001). The values for procalcitonin were not significantly increased in the control group (6h: 1.07±3.4 vs. 2.15±9.55, p=0.19) and lower for C-reactive protein (CRP) (24h: 147.1±64.0 vs.134.4±52.4 p=0.28). The use of a cell-saver and the processing of shed blood as an integral part of MiECC significantly reduces the systemic cytokine load. We, therefore, recommend the integration of cell-saving devices in MiECC to reduce the perioperative inflammatory response.
REGULATION OF MEMORY – FROM THE ADRENAL MEDULLA TO LIVER TO ASTROCYTES TO NEURONS1
Gold, Paul E.
2014-01-01
Epinephrine, released into blood from the adrenal medulla in response to arousing experiences, is a potent enhancer of learning and memory processing. This review examines mechanisms by which epinephrine exerts its effects on these cognitive functions. Because epinephrine is largely blocked from moving from blood to brain, it is likely that the hormone's effects on memory are mediated by peripheral actions. A classic effect of epinephrine is to act at the liver to break down glycogen stores, resulting in increased blood glucose levels. The increase in blood glucose provides additional energy substrates to the brain to buttress the processes needed for an experience to be learned and remembered. In part, it appears that the increased glucose may act in the brain in a manner akin to that evident in the liver, engaging glycogenolysis in astrocytes to provide an energy substrate, in this case lactate, to augment neuronal functions. Together, the findings reveal a mechanism underlying modulation of memory that integrates the physiological functions of multiple organ systems to support brain processes. PMID:24406469
Haemovigilance: A Current Update in Indian Perspective
Mukherjee, Somnath
2016-01-01
Haemovigilance is an organised scheme of monitoring, identifying, reporting, investigating and analysing adverse events and reactions pertinent to transfusion and manufacturing blood products. This system is also an elemental part of quality control in a blood system, bringing about corrective and preventive measures, and for the perpetual advancement of the quality and safety of blood products and the transfusion process. Nowadays haemovigilance setups have been enforced throughout the globe in most developed countries, to monitor the adverse reactions and episodes associated with blood donations and transfusions. Indian Pharmacopoeia Commission has started a Haemovigilance Program of India (HvPI) in 2012 under its Pharmacovigilance Program of India (PvPI) in collaboration with National Institute of Biologicals, Noida, Uttar Pradesh, under Ministry of Health and Family welfare, Government of India with a primary objective to track adverse reactions/events and incidences associated with blood transfusion and blood product administration and to identify trends, recommend best practices and interventions required to improve patient care and safety. This review article is a detail update of current scenario of haemovigilance in India. PMID:28050389
NASA Astrophysics Data System (ADS)
Nikitaev, V. G.; Nagornov, O. V.; Pronichev, A. N.; Polyakov, E. V.; Dmitrieva, V. V.
2017-12-01
The first stage of diagnostics of blood cancer is the analysis of blood smears. The application of decision-making support systems would reduce the subjectivity of the diagnostic process and avoid errors, resulting in often irreversible changes in the patient's condition. In this regard, the solution of this problem requires the use of modern technology. One of the tools of the program classification of blood cells are texture features, and the task of finding informative among them is promising. The paper investigates the effect of noise of the image sensor to informative texture features with application of methods of mathematical modelling.
Numerical simulations of a reduced model for blood coagulation
NASA Astrophysics Data System (ADS)
Pavlova, Jevgenija; Fasano, Antonio; Sequeira, Adélia
2016-04-01
In this work, the three-dimensional numerical resolution of a complex mathematical model for the blood coagulation process is presented. The model was illustrated in Fasano et al. (Clin Hemorheol Microcirc 51:1-14, 2012), Pavlova et al. (Theor Biol 380:367-379, 2015). It incorporates the action of the biochemical and cellular components of blood as well as the effects of the flow. The model is characterized by a reduction in the biochemical network and considers the impact of the blood slip at the vessel wall. Numerical results showing the capacity of the model to predict different perturbations in the hemostatic system are discussed.
Barriers and motivators to blood and cord blood donations in young African-American women.
Grossman, Brenda; Watkins, Andre R; Fleming, Faye; Debaun, Michael R
2005-03-01
The primary aim of this study was to assess potential barriers and motivators to blood and cord blood donation among African-American women. A telephone survey of African-American women, ages 18-30 years, in the St. Louis metropolitan area was performed. The survey was administered by trained telemarketing personnel using a Computer-Assisted Direct Interview (CADI) system. One hundred sixty-two women were surveyed. Common barriers to blood donation were inconvenience of donor sites (19%), fear of needles (16%), and too much time required to donate (15%). Potential motivators were increasing awareness of need for blood (43%), increasing the number of convenient donor locations (19%), and encouragement by spiritual leaders to have blood drives at their church (17%). Lack of awareness was the only identified barrier to cord blood donation. Most women surveyed (88%) indicated that they definitely or probably would donate cord blood. Strategies to increase the proportion of African-American blood and cord blood donations may include educating potential donors about the process and benefits of donation to particular patient populations and engaging church leadership in supporting blood and cord blood donations.
[Function of alveoles as a result of evolutionary development of respiratory system in mammals].
Ivanov, K P
2013-01-01
Reaction of hemoglobin oxygenation is known to occur for 40 femtoseconds (40 x 10(-15) s). However, the process of oxygen diffusion to hemoglobin under physiologic conditions decelerated this reaction approximately billion times. In mammalian lungs, blood is moving at a high rate and in a relatively high amount. The human lung mass is as low as 600 g, but the complete cardiac output approaches 6 1/min. In rat, from 20 to 40 ml of blood is passed for q min through the lung whose mass is about 1.5 g. Such blood flow rate is possible, as in lungs of high animals there exists a dense network of relatively large microvessels with diameter from 20 to 40 microm and more. In spite of a large volume and a high blood flow rate hampering oxygen diffusion, the complete blood oxygenation occurs in lung alveoli. This is due to peculiar mechanisms that facilitate markedly the oxygen diffusion and that developed in alveoli of mammals in the course of many million years of evolution of their respiratory system. Thus, alveolus is not a bubble with air, but a complex tool of fight with inertness of diffusion. It is interesting that in lungs of the low vertebrates, neither such system of blood vessels nor alveoli exist, and their blood flow rate is much lower than in mammals.
An in vitro test bench reproducing coronary blood flow signals.
Chodzyński, Kamil Jerzy; Boudjeltia, Karim Zouaoui; Lalmand, Jacques; Aminian, Adel; Vanhamme, Luc; de Sousa, Daniel Ribeiro; Gremmo, Simone; Bricteux, Laurent; Renotte, Christine; Courbebaisse, Guy; Coussement, Grégory
2015-08-07
It is a known fact that blood flow pattern and more specifically the pulsatile time variation of shear stress on the vascular wall play a key role in atherogenesis. The paper presents the conception, the building and the control of a new in vitro test bench that mimics the pulsatile flows behavior based on in vivo measurements. An in vitro cardiovascular simulator is alimented with in vivo constraints upstream and provided with further post-processing analysis downstream in order to mimic the pulsatile in vivo blood flow quantities. This real-time controlled system is designed to perform real pulsatile in vivo blood flow signals to study endothelial cells' behavior under near physiological environment. The system is based on an internal model controller and a proportional-integral controller that controls a linear motor with customized piston pump, two proportional-integral controllers that control the mean flow rate and temperature of the medium. This configuration enables to mimic any resulting blood flow rate patterns between 40 and 700 ml/min. In order to feed the system with reliable periodic flow quantities in vivo measurements were performed. Data from five patients (1 female, 4 males; ages 44-63) were filtered and post-processed using the Newtonian Womersley's solution. These resulting flow signals were compared with 2D axisymmetric, numerical simulation using a Carreau non-Newtonian model to validate the approximation of a Newtonian behavior. This in vitro test bench reproduces the measured flow rate time evolution and the complexity of in vivo hemodynamic signals within the accuracy of the relative error below 5%. This post-processing method is compatible with any real complex in vivo signal and demonstrates the heterogeneity of pulsatile patterns in coronary arteries among of different patients. The comparison between analytical and numerical solution demonstrate the fair quality of the Newtonian Womersley's approximation. Therefore, Womersley's solution was used to calculate input flow rate for the in vitro test bench.
Relative Risks of Thrombosis and Bleeding in Different ABO Blood Groups.
Franchini, Massimo; Lippi, Giuseppe
2016-03-01
The ABO blood group system is composed of complex carbohydrate molecules (i.e., the A, B, and H determinants) that are widely expressed on the surface of red blood cells and in a variety of other cell and tissues. Along with their pivotal role in transfusion and transplantation medicine, the ABO antigens participate in many other physiological processes and, in particular, are important determinants of von Willebrand factor and factor VIII circulating plasma levels. The precise influence of the ABO system on hemostasis has led the way to the investigation of a putative implication in the risk of developing cardiovascular disorders. Along with the underlying molecular mechanisms, the current knowledge on the role of ABO blood group antigens in both the thrombotic and hemorrhagic risk will be summarized in this narrative review. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.
Rotating permanent magnet excitation for blood flow measurement.
Nair, Sarath S; Vinodkumar, V; Sreedevi, V; Nagesh, D S
2015-11-01
A compact, portable and improved blood flow measurement system for an extracorporeal circuit having a rotating permanent magnetic excitation scheme is described in this paper. The system consists of a set of permanent magnets rotating near blood or any conductive fluid to create high-intensity alternating magnetic field in it and inducing a sinusoidal varying voltage across the column of fluid. The induced voltage signal is acquired, conditioned and processed to determine its flow rate. Performance analysis shows that a sensitivity of more than 250 mV/lpm can be obtained, which is more than five times higher than conventional flow measurement systems. Choice of rotating permanent magnet instead of an electromagnetic core generates alternate magnetic field of smooth sinusoidal nature which in turn reduces switching and interference noises. These results in reduction in complex electronic circuitry required for processing the signal to a great extent and enable the flow measuring device to be much less costlier, portable and light weight. The signal remains steady even with changes in environmental conditions and has an accuracy of greater than 95%. This paper also describes the construction details of the prototype, the factors affecting sensitivity and detailed performance analysis at various operating conditions.
Kaur, Indreshpal; Zulovich, Jane M; Gonzalez, Marissa; McGee, Kara M; Ponweera, Nirmali; Thandi, Daljit; Alvarez, Enrique F; Annandale, Kathy; Flagge, Frank; Rezvani, Katayoun; Shpall, Elizabeth
2017-03-01
Umbilical cord blood (CB) is being used as a source of hematopoietic stem cells (HSCs) and immune cells to treat many disorders. Because these cells are present in low numbers in CB, investigators have developed strategies to expand HSCs and other immune cells such as natural killer (NK) cells. The initial step in this process is to enrich mononuclear cells (MNCs) while depleting unwanted cells. The manual method of MNC enrichment is routinely used by many centers; however, it is an open system, time-consuming and operator dependent. For clinical manufacturing, it is important to have a closed system to avoid microbial contamination. In this study, we optimized an automated, closed system (Sepax) for enriching MNCs from cryopreserved CB units. Using Sepax, we observed higher recovery of total nucleated cells (TNC), CD34 + cells, NK cells and monocytes when compared to manual enrichment, despite similar TNC and CD34 + viability with the two methods. Even though the depletion of red blood cells, granulocytes and platelets was superior using the manual method, significantly higher CFU-GM were obtained in MNCs enriched using Sepax compared to the manual method. This is likely related to the fact that the automated Sepax significantly shortened the processing time (Sepax: 74 - 175 minutes versus manual method: 180 - 290 minutes). The use of DNAse and MgCl 2 during the Sepax thaw and wash procedure prevents clumping of cells and loss of viability, resulting in improved post-thaw cell recovery. We optimized enrichment of MNCs from cryopreserved CB products in a closed system using the Sepax which is a walk away and automated processing system. Copyright © 2017 International Society for Cellular Therapy. Published by Elsevier Inc. All rights reserved.
Platelet activation by extracellular matrix proteins in haemostasis and thrombosis.
Watson, Steve P
2009-01-01
The prevention of excessive blood loss to avoid fatal haemorrhage is a pivotal process for all organisms possessing a circulatory system. Increased circulating blood volume and pressure, as required in larger animals, make this process all the more important and challenging. It is essential to have a powerful and rapid system to detect damage and generate an effective seal, and which is also exquisitely regulated to prevent unwanted, excessive or systemic activation so as to avoid blockage of vessels. Thus, a highly specialised and efficient haemostatic system has evolved that consists of cellular (platelets) and protein (coagulation factors) components. Importantly, this is able to support haemostasis in both the low shear environment of the venous system and the high shear environment of the arterial system. Endothelial cells, lining the entire circulation system, play a crucial role in the delicate balance between activation and inhibition of the haemostatic system. An intact and healthy endothelium supports blood flow by preventing attachment of cells and proteins which is required for initiation of coagulation and platelet activation. Endothelial cells produce and release the two powerful soluble inhibitors of platelet activation, nitric oxide and prostacyclin, and express high levels of CD39 which rapidly metabolises the major platelet feedback agonist, ADP. This antithrombotic environment however can rapidly change following activation or removal of endothelial cells through injury or rupture of atherosclerotic plaques. Loss of endothelial cells exposes the subendothelial extracellular matrix which creates strong signals for activation of the haemostatic system including powerful platelet adhesion and activation. Quantitative and qualitative changes in the composition of the subendothelial extracellular matrix influence these prothrombotic characteristics with life threatening thrombotic and bleeding complications, as illustrated by formation of atherosclerotic plaques or the disorder Ehler-Danlos syndrome, which is caused by a defect in collagen synthesis and is associated with fragile blood vessels. This review will focus on the role of the subendothelial matrix in haemostasis and thrombosis, highlighting its potential as a target for novel antithrombotics.
Blood management issues using blood management strategies.
Stulberg, Bernard N; Zadzilka, Jayson D
2007-06-01
Blood management strategies is a term used to address a coordinated approach to the management of blood loss in the perioperative period for total joint arthroplasty. The premise of any blood management strategy is that each patient, surgeon, and operative intervention experiences different risks of requiring transfusion, that those risks can be identified, and that a plan can be implemented to address them. A surgeon's decision to transfuse should be based on physiologic assessment of the patient's response to anemia and not on an arbitrary number ("transfusion trigger"). Intervention strategies can be applied preoperatively, intraoperatively, and postoperatively. Patient-specific planning allows for the appropriate use of patient, hospital, and system resources, ensuring that the consequences of anemia are minimized and that the patient's recovery process is optimized.
Melanson, Stacy E F; Goonan, Ellen M; Lobo, Margaret M; Baum, Jonathan M; Paredes, José D; Santos, Katherine S; Gustafson, Michael L; Tanasijevic, Milenko J
2009-12-01
Our goals were to improve the overall patient experience and optimize the blood collection process in outpatient phlebotomy using Lean principles. Elimination of non-value-added steps and modifications to operational processes resulted in increased capacity to handle workload during peak times without adding staff. The result was a reduction of average patient wait time from 21 to 5 minutes, with the goal of drawing blood samples within 10 minutes of arrival at the phlebotomy station met for 90% of patients. In addition, patient satisfaction increased noticeably as assessed by a 5-question survey. The results have been sustained for 10 months with staff continuing to make process improvements.
Mathematical model with autoregressive process for electrocardiogram signals
NASA Astrophysics Data System (ADS)
Evaristo, Ronaldo M.; Batista, Antonio M.; Viana, Ricardo L.; Iarosz, Kelly C.; Szezech, José D., Jr.; Godoy, Moacir F. de
2018-04-01
The cardiovascular system is composed of the heart, blood and blood vessels. Regarding the heart, cardiac conditions are determined by the electrocardiogram, that is a noninvasive medical procedure. In this work, we propose autoregressive process in a mathematical model based on coupled differential equations in order to obtain the tachograms and the electrocardiogram signals of young adults with normal heartbeats. Our results are compared with experimental tachogram by means of Poincaré plot and dentrended fluctuation analysis. We verify that the results from the model with autoregressive process show good agreement with experimental measures from tachogram generated by electrical activity of the heartbeat. With the tachogram we build the electrocardiogram by means of coupled differential equations.
Platelets as delivery systems for disease treatments
Shi, Qizhen; Montgomery, Robert R.
2010-01-01
Platelets are small, anucleate, discoid shaped blood cells that play a fundamental role in hemostasis. Platelets contain a large number of biologically active molecules within cytoplasmic granules that are critical to normal platelet function. Because platelets circulate in blood through out the body, release biological molecules and mediators on demand, and participate in hemostasis as well as many other pathophysiologic processes, targeting expression of proteins of interest to platelets and utilizing platelets as delivery systems for disease treatment would be a logical approach. This paper reviews the genetic therapy for inherited bleeding disorders utilizing platelets as delivery system, with a particular focus on platelet-derived FVIII for hemophilia A treatment. PMID:20619307
Aging and brain rejuvenation as systemic events
Bouchard, Jill; Villeda, Saul A
2015-01-01
The effects of aging were traditionally thought to be immutable, particularly evident in the loss of plasticity and cognitive abilities occurring in the aged central nervous system (CNS). However, it is becoming increasingly apparent that extrinsic systemic manipulations such as exercise, caloric restriction, and changing blood composition by heterochronic parabiosis or young plasma administration can partially counteract this age-related loss of plasticity in the aged brain. In this review, we discuss the process of aging and rejuvenation as systemic events. We summarize genetic studies that demonstrate a surprising level of malleability in organismal lifespan, and highlight the potential for systemic manipulations to functionally reverse the effects of aging in the CNS. Based on mounting evidence, we propose that rejuvenating effects of systemic manipulations are mediated, in part, by blood-borne ‘pro-youthful’ factors. Thus, systemic manipulations promoting a younger blood composition provide effective strategies to rejuvenate the aged brain. As a consequence, we can now consider reactivating latent plasticity dormant in the aged CNS as a means to rejuvenate regenerative, synaptic, and cognitive functions late in life, with potential implications even for extending lifespan. PMID:25327899
... process in which the body's immune system sends eosinophils (white blood cells distinguished by their lobulated nuclei ... orange eosin stain) to attack fungi, and the eosinophils irritate the membranes in the nose. As long ...
Thibault, L; Beauséjour, A; Jacques, A; Ducas, E; Tremblay, M
2014-02-01
Many countries allow the overnight storage of whole blood (WB) at ambient temperature. Some countries, such as Canada, also require a rapid cooling of WB with an active cooling system. Given the significant operational constraints associated with current cooling systems, an alternative method for cooling and transporting WB at 20-24°C was evaluated. Phase 22 cooling packs (TCP Reliable Inc., USA) were used in combination with vacuum-insulated panel (VIP) boxes. Temperature profiles of simulated WB units were studied in extreme temperatures (-35 and 40°C). The quality of blood components prepared using Phase 22 packs and CompoCool-WB (Fresenius HemoCare, Germany) was studied. Phase 22 packs reduced the temperature of simulated WB bags from 37 to 24°C in 1·7 ± 0·2 h. Used in combination with VIP boxes, Phase 22 packs maintain the temperature of bags between 20 and 24°C for 15 and 24 h, compared to 2 and 11 h with CompoCool-WB, when exposed at -35 and 40°C, respectively. The quality of platelet concentrates and plasma was comparable, regardless of the cooling system used. For red blood cell units, per cent haemolysis on day 42 was slightly higher in products prepared after cooling with Phase 22 packs compared to CompoCool-WB (0·33 ± 0·15% vs. 0·21 ± 0·06%; P < 0·05). Phase 22 packs combined with VIP boxes are an acceptable alternative to butane-1,4-diol cooling systems. This system allows blood manufacturers to transport WB to processing facilities in a broad range of environmental conditions. © 2013 International Society of Blood Transfusion.
Patent ductus arteriosus: patho-physiology, hemodynamic effects and clinical complications.
Capozzi, Giovanbattista; Santoro, Giuseppe
2011-10-01
During fetal life, patent arterial duct diverts placental oxygenated blood from the pulmonary artery into the aorta by-passing lungs. After birth, decrease of prostacyclins and prostaglandins concentration usually causes arterial duct closure. This process may be delayed, or may even completely fail in preterm infants with arterial duct still remaining patent. If that happens, blood flow by-pass of the systemic circulation through the arterial duct results in pulmonary overflow and systemic hypoperfusion. When pulmonary flow is 50% higher than systemic flow, a hemodynamic "paradox" results, with an increase of left ventricular output without a subsequent increase of systemic output. Cardiac overload support neuro-humoral effects (activation of sympathetic nervous system and renin-angiotensin system) that finally promote heart failure. Moreover, increased pulmonary blood flow can cause vascular congestion and pulmonary edema. However, the most dangerous effect is cerebral under-perfusion due to diastolic reverse-flow and resulting in cerebral hypoxia. At last, blood flow decreases through the abdominal aorta, reducing perfusion of liver, gut and kidneys and may cause hepatic failure, renal insufficiency and necrotizing enterocolitis. Conclusions Large patent arterial duct may cause life-threatening multi-organ effects. In pre-term infant early diagnosis and timely effective treatment are cornerstones in the prevention of cerebral damage and long-term multi-organ failure.
Aging: a portrait from gene expression profile in blood cells.
Calabria, Elisa; Mazza, Emilia Maria Cristina; Dyar, Kenneth Allen; Pogliaghi, Silvia; Bruseghini, Paolo; Morandi, Carlo; Salvagno, Gian Luca; Gelati, Matteo; Guidi, Gian Cesare; Bicciato, Silvio; Schiaffino, Stefano; Schena, Federico; Capelli, Carlo
2016-08-01
The availability of reliable biomarkers of aging is important not only to monitor the effect of interventions and predict the timing of pathologies associated with aging but also to understand the mechanisms and devise appropriate countermeasures. Blood cells provide an easily available tissue and gene expression profiles from whole blood samples appear to mirror disease states and some aspects of the aging process itself. We report here a microarray analysis of whole blood samples from two cohorts of healthy adult and elderly subjects, aged 43±3 and 68±4 years, respectively, to monitor gene expression changes in the initial phase of the senescence process. A number of significant changes were found in the elderly compared to the adult group, including decreased levels of transcripts coding for components of the mitochondrial respiratory chain, which correlate with a parallel decline in the maximum rate of oxygen consumption (VO2max), as monitored in the same subjects. In addition, blood cells show age-related changes in the expression of several markers of immunosenescence, inflammation and oxidative stress. These findings support the notion that the immune system has a major role in tissue homeostasis and repair, which appears to be impaired since early stages of the aging process.
Spoerl, Silvia; Peter, Robert; Wäscher, Dagmar; Verbeek, Mareike; Menzel, Helge; Peschel, Christian; Krackhardt, Angela M
2015-11-01
In several European countries, preparation of cellular products with open manufacturing systems as used for cryopreservation of peripheral blood stem cells (PBSCs) needs to be performed in a clean-room facility. However, this form of manufacturing is highly expensive and laborious. Thus, safe techniques providing improved efficacy regarding time and material, which are in accordance with legal requirements are highly desirable. We have developed, validated, and applied a simple method for cryopreservation of PBSCs within a functionally closed-bag system using the closed cryo freeze prep set. This process fulfills good manufacturing practice requirements and allows for the cryopreservation of PBSCs without a clean-room facility. In addition to cryopreservation of PBSCs, we have recently successfully modified our system for processing, portioning, and cryopreservation of allogeneic donor lymphocytes. Since 2010, cryopreservation of PBSCs using a closed-bag system has been performed in our facility on a routine basis and 210 patients and healthy donors have been included in this analysis. No significant reduction in viability of CD34+ cells and no process-related contamination were observed. Outcome of hematopoietic stem cell transplantation regarding time of engraftment and infectious complications is comparable to products manufactured in conventional clean-room facilities. Our data confirm that cryopreservation of PBSCs within a functionally closed-bag system is safe, effective, and economical. Furthermore, the system has the potential to be extended to other manufacturing processes of cellular products. © 2015 AABB.
Seiwerth, Sven; Brcic, Luka; Vuletic, Lovorka Batelja; Kolenc, Danijela; Aralica, Gorana; Misic, Marija; Zenko, Anita; Drmic, Domagoj; Rucman, Rudolf; Sikiric, Predrag
2014-01-01
This review focuses on the described effects of BPC 157 on blood vessels after different types of damage, and elucidate by investigating different aspects of vascular response to injury (endothelium damage, clotting, thrombosis, vasoconstriction, vasodilatation, vasculoneogenesis and edema formation) especially in connection to the healing processes. In this respect, BPC 157 was concluded to be the most potent angiomodulatory agent, acting through different vasoactive pathways and systems (e.g. NO, VEGF, FAK) and leading to optimization of the vascular response followed, as it has to be expected, by optimization of the healing process. Formation of new blood vessels involves two main, partly overlapping mechanisms, angiogenesis and vasculogenesis. The additional mechanism of arteriogenesis is involved in the formation of collaterals. In conjunction with blood vessel function, we at least have to consider leakage of fluid/proteins/plasma, resulting in edema/exudate formation as well as thrombogenesis. Blood vessels are also strongly involved in tumor biology. In this aspect, we have neoangiogenesis resulting in pathological vascularization, vascular invasion resulting in release of metastatic cells and the phenomenon of homing resulting in formation of secondary tumors--metastases.
Cattani, María E; Posse, Tamara; Hermes, Ricardo L; Kaufman, Sara C
2015-01-01
Rapid identification of microorganisms is critical in hospitalized infected patients. Blood culture is currently the gold standard for detecting and identifying microorganisms causing bacteremia or sepsis. The introduction of mass spectrometry by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF MS) in microbiology laboratories, especially in microorganisms growing in blood culture bottles, provides rapid identification. This study evaluates the performance of the Maldi Sepsityper Biotyper procedure (hereinafter, MS) compared to that of an in-home method (hereinafter, HF). Eight hundred and forty (840) positive blood culture bottles were processed using the HF procedure, 542 of which were also processed using MS. The organisms were identified in 670 (79.76%) and 391 (72.14%) bottles respectively (p = 0,0013). This study demonstrates the effectiveness of both procedures for identifying microorganisms directly from positive blood culture bottles. However, the HF procedure proved to be more effective than MS, especially in the presence of Gram positive organisms. Copyright © 2015 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Automated registration of tail bleeding in rats.
Johansen, Peter B; Henriksen, Lars; Andresen, Per R; Lauritzen, Brian; Jensen, Kåre L; Juhl, Trine N; Tranholm, Mikael
2008-05-01
An automated system for registration of tail bleeding in rats using a camera and a user-designed PC-based software program has been developed. The live and processed images are displayed on the screen and are exported together with a text file for later statistical processing of the data allowing calculation of e.g. number of bleeding episodes, bleeding times and bleeding areas. Proof-of-principle was achieved when the camera captured the blood stream after infusion of rat whole blood into saline. Suitability was assessed by recording of bleeding profiles in heparin-treated rats, demonstrating that the system was able to capture on/off bleedings and that the data transfer and analysis were conducted successfully. Then, bleeding profiles were visually recorded by two independent observers simultaneously with the automated recordings after tail transection in untreated rats. Linear relationships were found in the number of bleedings, demonstrating, however, a statistically significant difference in the recording of bleeding episodes between observers. Also, the bleeding time was longer for visual compared to automated recording. No correlation was found between blood loss and bleeding time in untreated rats, but in heparinized rats a correlation was suggested. Finally, the blood loss correlated with the automated recording of bleeding area. In conclusion, the automated system has proven suitable for replacing visual recordings of tail bleedings in rats. Inter-observer differences can be eliminated, monotonous repetitive work avoided, and a higher through-put of animals in less time achieved. The automated system will lead to an increased understanding of the nature of bleeding following tail transection in different rodent models.
Development of portable health monitoring system for automatic self-blood glucose measurement
NASA Astrophysics Data System (ADS)
Kim, Huijun; Mizuno, Yoshihumi; Nakamachi, Eiji; Morita, Yusuke
2010-02-01
In this study, a new HMS (Health Monitoring System) device is developed for diabetic patient. This device mainly consists of I) 3D blood vessel searching unit and II) automatic blood glucose measurement (ABGM) unit. This device has features such as 1)3D blood vessel location search 2) laptop type, 3) puncturing a blood vessel by using a minimally invasive micro-needle, 4) very little blood sampling (10μl), and 5) automatic blood extraction and blood glucose measurement. In this study, ABGM unit is described in detail. It employs a syringe type's blood extraction mechanism because of its high accuracy. And it consists of the syringe component and the driving component. The syringe component consists of a syringe itself, a piston, a magnet, a ratchet and a micro-needle whose inner diameter is about 80μm. And the syringe component is disposable. The driving component consists of body parts, a linear stepping motor, a glucose enzyme sensor and a slider for accurate positioning control. The driving component has the all-in-one mechanism with a glucose enzyme sensor for compact size and stable blood transfer. On designing, required thrust force to drive the slider is designed to be greater than the value of the blood extraction force. Further, only one linear stepping motor is employed for blood extraction and transportation processes. The experimental result showed more than 80% of volume ratio under the piston speed 2.4mm/s. Further, the blood glucose was measured successfully by using the prototype unit. Finally, the availability of our ABGM unit was confirmed.
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... for Red Blood Cells shall be the original blood containers unless the method of processing requires a...
Lovering, Andrew T; Elliott, Jonathan E; Davis, James T
2016-08-01
The foramen ovale, which is part of the normal fetal cardiopulmonary circulation, fails to close after birth in ∼35% of the population and represents a potential source of right-to-left shunt. Despite the prevalence of patent foramen ovale (PFO) in the general population, cardiopulmonary, exercise, thermoregulatory, and altitude physiologists may have underestimated the potential effect of this shunted blood flow on normal physiological processes in otherwise healthy humans. Because this shunted blood bypasses the respiratory system, it would not participate in either gas exchange or respiratory system cooling and may have impacts on other physiological processes that remain undetermined. The consequences of this shunted blood flow in PFO-positive (PFO+) subjects can potentially have a significant, and negative, impact on the alveolar-to-arterial oxygen difference (AaDO2), ventilatory acclimatization to high altitude and respiratory system cooling with PFO+ subjects having a wider AaDO2 at rest, during exercise after acclimatization, blunted ventilatory acclimatization, and a higher core body temperature (∼0.4(°)C) at rest and during exercise. There is also an association of PFO with high-altitude pulmonary edema and acute mountain sickness. These effects on physiological processes are likely dependent on both the presence and size of the PFO, with small PFOs not likely to have significant/measureable effects. The PFO can be an important determinant of normal physiological processes and should be considered a potential confounder to the interpretation of former and future data, particularly in small data sets where a significant number of PFO+ subjects could be present and significantly impact the measured outcomes.
Electronic circuit detects left ventricular ejection events in cardiovascular system
NASA Technical Reports Server (NTRS)
Gebben, V. D.; Webb, J. A., Jr.
1972-01-01
Electronic circuit processes arterial blood pressure waveform to produce discrete signals that coincide with beginning and end of left ventricular ejection. Output signals provide timing signals for computers that monitor cardiovascular systems. Circuit operates reliably for heart rates between 50 and 200 beats per minute.
Burnouf, Thierry; Chou, Ming-Li; Goubran, Hadi; Cognasse, Fabrice; Garraud, Olivier; Seghatchian, Jerard
2015-10-01
Blood cells and tissues generate heterogeneous populations of cell-derived vesicles, ranging from approximately 50 nm to 1 µm in diameter. Under normal physiological conditions and as an essential part of an energy-dependent natural process, microparticles (MPs) are continuously shed into the circulation from membranes of all viable cells such as megakaryocytes, platelets, red blood cells, white blood cells and endothelial cells. MP shedding can also be triggered by pathological activation of inflammatory processes and activation of coagulation or complement systems, or even by shear stress in the circulation. Structurally, MPs have a bilayered phospholipid structure exposing coagulant-active phosphatidylserine and expressing various membrane receptors, and they serve as cell-to-cell shuttles for bioactive molecules such as lipids, growth factors, microRNAs, and mitochondria. It was established that ex vivo processing of blood into its components, involving centrifugation, processing by various apheresis procedures, leucoreduction, pathogen reduction, and finally storage in different media and different types of blood bags, can impact MP generation and content. This is mostly due to exposure of the collected blood to anticoagulant/storage media and due to shear stresses or activation, contact with artificial surfaces, or exposure to various leucocyte-removal filters and pathogen-reduction treatments. Such artificially generated MPs, which are added to the original pool of MPs collected from the donor, may exhibit specific functional characteristics, as MPs are not an inert element of blood components. Not surprisingly, MPs' roles and functionality are therefore increasingly seen to be fully relevant to the field of transfusion medicine, and as a parameter of blood safety that must be considered in haemovigilance programmes. Continual advancements in assessment methods of MPs and storage lesions are gradually leading to a better understanding of the impacts of blood collection on MP generation, while clinical research should clarify links of MPs with transfusion reactions and certain clinical disorders. Harmonization and consensus in sampling protocols, sample handling and processing, and assessment methods are needed to achieve consensual interpretations. This review focuses on the role of MPs as an essential laboratory tool and as a most effective player in transfusion science and medicine and in health and disease. Copyright © 2015 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Prijono, Agus; Darmawan Hangkawidjaja, Aan; Ratnadewi; Saleh Ahmar, Ansari
2018-01-01
The verification to person who is used today as a fingerprint, signature, personal identification number (PIN) in the bank system, identity cards, attendance, easily copied and forged. This causes the system not secure and is vulnerable to unauthorized persons to access the system. In this research will be implemented verification system using the image of the blood vessels in the back of the palms as recognition more difficult to imitate because it is located inside the human body so it is safer to use. The blood vessels located at the back of the human hand is unique, even humans twins have a different image of the blood vessels. Besides the image of the blood vessels do not depend on a person’s age, so it can be used for long term, except in the case of an accident, or disease. Because of the unique vein pattern recognition can be used in a person. In this paper, we used a modification method to perform the introduction of a person based on the image of the blood vessel that is using Modified Local Line Binary Pattern (MLLBP). The process of matching blood vessel image feature extraction using Hamming Distance. Test case of verification is done by calculating the percentage of acceptance of the same person. Rejection error occurs if a person was not matched by the system with the data itself. The 10 person with 15 image compared to 5 image vein for each person is resulted 80,67% successful Another test case of the verification is done by verified two image from different person that is forgery, and the verification will be true if the system can rejection the image forgery. The ten different person is not verified and the result is obtained 94%.
Yin, Wenjing; Xu, Zhengliang; Sheng, Jiagen; Xie, Xuetao; Zhang, Changqing
2017-09-01
Erythrocyte sedimentation rate (ESR), which reflects the sedimentation rate of platelets, leukocytes and erythrocytes in response to centrifugal force, may influence the cellular composition of platelet-rich plasma (PRP) obtained via centrifugation methods. However, no relevant studies have substantiated this. In the present study, blood was collected from 40 healthy volunteers and used to prepare PRP with two plasma-based preparation systems [YinPRP and Plasma Rich in Growth Factor (PRGF) systems] and two buffy coat-based systems (RegenPRP and WEGOPRP systems) in a single-donor model. Volumes of PRP and platelet-poor plasma (PPP) that were removed in the preparation process were recorded. Analyses of ESR, haematocrit, C-reaction protein, coagulation, serum glucose and serum lipid of the whole blood used for PRP preparation were performed to evaluate the levels of ESR and the factors known to influence it. Whole blood analysis was performed to evaluate the cellular composition of PRP. Results demonstrated that there were marked positive correlations between the ESR of the whole blood used for PRP preparation and PPP removal efficiencies, platelet concentrations, platelet capture efficiencies and platelet enrichment factors of PRP formulations obtained from plasma-based systems, and PRP yield efficiency of RegenPRP and PPP removal efficiency of WEGOPRP. Furthermore, there were marked negative correlations between ESR and concentrations and enrichment factors of platelets, leukocytes and erythrocytes of RegenPRP. Fibrinogen concentration of the whole blood, which had a marked positive correlation with ESR, also influenced the cellular composition of PRP. These findings may increase the understanding of PRP preparation and provide substantial evidence for the individualised optimisation of PRP preparation systems used in clinical practice.
Yamazaki, K; Mori, T; Tomioka, J; Litwak, P; Antaki, J F; Tagusari, O; Koyanagi, H; Griffith, B P; Kormos, R L
1997-01-01
A critical issue facing the development of an implantable, rotary blood pump is the maintenance of an effective seal at the rotating shaft. Mechanical seals are the most versatile type of seal in wide industrial applications. However, in a rotary blood pump, typical seal life is much shorter than required for chronic support. Seal failure is related to adhesion and aggregation of heat denatured blood proteins that diffuse into the lubricating film between seal faces. Among the blood proteins, fibrinogen plays an important role due to its strong propensity for adhesion and low transition temperature (approximately 50 degrees C). Once exposed to temperature exceeding 50 degrees C, fibrinogen molecules fuse together by multi-attachment between heat denatured D-domains. This quasi-polymerized fibrin increases the frictional heat, which proliferates the process into seal failure. If the temperature of the seal faces is maintained well below 50 degrees C, a mechanical seal would not fail in blood. Based on this "Cool-Seal" concept, we developed a miniature mechanical seal made of highly thermally conductive material (SiC), combined with a recirculating purge system. A large supply of purge fluid is recirculated behind the seal face to augment convective heat transfer to maintain the seal temperature below 40 degrees C. It also cools all heat generating pump parts (motor coil, bearing, seal). The purge consumption has been optimized to virtually nil (< 0.5 cc/day). An ultrafiltration unit integrated in the recirculating purge system continuously purifies and sterilizes the purge fluid for more than 5 months without filter change. The seal system has now been incorporated into our intraventricular axial flow blood pump (IVAP) and newly designed centrifugal pump. Ongoing in vivo evaluation of these systems has demonstrated good seal integrity for more than 160 days. The Cool-Seal system can be applied to any type of rotary blood pump (axial, diagonal, centrifugal, etc.) and offers a practical solution to the shaft seal problem and heat related complications, which currently limit the use of implantable rotary blood pumps.
2003-01-01
Adis CommentsCerus Corporation is developing a variety of pathogen-inactivation systems, based on its Helinx technology. Three of the systems include amotosalen [S 59] as the inactivation compound. Amotosalen is a light-activated, DNA-, RNA-crosslinking psoralen compound, which is used to neutralise pathogens. The systems that utilise amotosalen are called the INTERCEPT Platelet System, the INTERCEPT Plasma System and the Allogeneic Cellular Immunotherapies (ACIT) system. The INTERCEPT Platelet System and INTERCEPT Plasma System are two of the systems that make up Cerus' INTERCEPT Blood Systems. The other system is the INTERCEPT Red Blood Cell System, which contains S 303 as the inactivation compound rather than amotosalen. Cerus' Helinx technology is able to prevent replication of DNA or RNA that is present in pathogens but not in the blood components being treated (e.g. platelets and plasma). When added to the blood components, the inactivation agent (in this case amotosalen) crosses the membrane or cell wall of the pathogen. When activated by light, amotosalen binds to the nucleic acid of the pathogen and prevents replication. This process prevents infection. INTERCEPT Platelet System: Cerus developed its INTERCEPT Platelet System, in collaboration with Baxter Healthcare, for use in blood centres. Platelets are an essential component of the coagulation process and may be required by patients undergoing surgery, cancer chemotherapy, transplantation or with bleeding disorders. The system is made up of an illuminator device, a compound absorption device and a processing kit containing amotosalen. In October 2002, the two companies announced that CE Mark approval had been received for the illuminator device for the INTERCEPT trade mark Blood System. Application of this technology to platelets is the first to be approved. As it is a new technology, the system is currently undergoing process validation in accordance with European Blood Bank GMP requirements. This validation process is currently being conducted in Denmark, France, Germany, Sweden and the UK. Marketing approval applications for the INTERCEPT Platelet System have also been submitted in Australia and Canada. In addition, the regulatory submission process has begun in the US. A phase III trial (EuroSPRITE) has been conducted in 103 patients in Europe with pooled random donor platelets. The platelets were collected using the buffy coat process. Another two 20-patient clinical trials have also been conducted in Europe, as well as a 40-patient trial using platelets collected by an apheresis collection system. Cerus has also conducted a phase III trial (SPRINT) in the US. The trial was conducted in 671 patients and used platelets collected by Baxter's apheresis collection system. INTERCEPT Plasma System: Cerus is also developing the INTERCEPT Plasma System in collaboration with Baxter Healthcare. The system also combines amotosalen, an illumination device and a compound absorption device. The two companies are currently preparing regulatory applications for the INTERCEPT Plasma System for the US. This application will be followed by a submission for CE Mark designation in Europe. Patients undergoing surgery, or transplantation, or with bleeding disorders, may require transfusions of plasma, often to control bleeding. The type of plasma is stored in frozen form and is called fresh frozen plasma (FFP). The INTERCEPT Plasma System is currently in phase IIIc development in the US. Patient enrolment in the trial is still ongoing. The trial is comparing INTERCEPT trade mark Plasma System treated versus untreated FFP in 30 patients with thrombotic thrombocytopenic purpura. Allogeneic Cellular Immunotherapies system: Cerus is also investigating the potential of its Helinx technology to improve the outcome of bone marrow transplantation procedures (used to treat leukaemia and lymphoma) through the treatmatment for many forms of leukaemia and is most effective when the donor is very closely matched to the patient for the major human leucocyte antigen (HLA) groups. As part of the transplant procedure, patients receive donor T cells to improve engraftment of the bone marrow transplant and strengthen the patient's immune system. However, donor T cells expose the patient to a high risk of contracting graft-versus-host disease (GVHD) caused by the proliferation of donor T cells, which attack the patient's healthy tissue. GVHD has a high mortality rate. Cerus' ACIT system has been developed to decrease the stringency of matching donors to patients and to inhibit the ability of donor T cells to cause GVHD. Light-activated amotosalen binds and permanently crosslinks DNA, preventing replication and thus stopping proliferation of donor T cells. Phase I development is currently being conducted in this area in the US using amotosalen as the neutralising agent. Cerus completed a phase I study investigating the safety and tolerability of its ACIT system in 2001. The study was conducted in patients receiving closely matched allogeneic bone marrow transplants for leukaemia. The company is currently collaborating with the National Marrow Donor Program in order to conduct further clinical studies in patients receiving bone marrow transplants from unmatched donors. Cerus has development, manufacturing and marketing agreements with Baxter covering the INTERCEPT Blood Systems, which includes the INTERCEPT Platelet system, the INTERCEPT Plasma System, and the INTERCEPT Red Blood Cell System. Under the terms of the agreements the two companies usually share the very early development activities. Cerus then conducts preclinical and clinical trials, while Baxter is responsible for the development of the systems disposables and devices. Following commercialisation Cerus will supply amotosalen and Baxter will supply the other components of the system and market, sell and distribute the system In January 2001, Cereus announced that it has entered into a collaborative agreement with the Pharmaceutical Division of Kirin Brewery in Japan to develop and market products for stem cell transplantation based on Cerus' proprietary Helinx technology. Under terms of the agreement, Cerus and Kirin will jointly develop the products. Cerus has received an initial license fee of US dollar 1 million. In addition it may receive up to US dollar 11 million in future payments upon achievement of development milestones. Kirin will also fund all development expenses for the Asia-Pacific region and a portion of Cerus' development activities aimed at obtaining product approval in the US. Kirin will market the products in the Asia-Pacific region, including Japan, China, Korea and Australia, and Cerus will receive a specified share of product revenues. Cerus will retain marketing rights in the rest of the world, including the US and Europe.
Point-of-Care Test Equipment for Flexible Laboratory Automation.
You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol
2014-08-01
Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.
Systems engineering principles for the design of biomedical signal processing systems.
Faust, Oliver; Acharya U, Rajendra; Sputh, Bernhard H C; Min, Lim Choo
2011-06-01
Systems engineering aims to produce reliable systems which function according to specification. In this paper we follow a systems engineering approach to design a biomedical signal processing system. We discuss requirements capturing, specification definition, implementation and testing of a classification system. These steps are executed as formal as possible. The requirements, which motivate the system design, are based on diabetes research. The main requirement for the classification system is to be a reliable component of a machine which controls diabetes. Reliability is very important, because uncontrolled diabetes may lead to hyperglycaemia (raised blood sugar) and over a period of time may cause serious damage to many of the body systems, especially the nerves and blood vessels. In a second step, these requirements are refined into a formal CSP‖ B model. The formal model expresses the system functionality in a clear and semantically strong way. Subsequently, the proven system model was translated into an implementation. This implementation was tested with use cases and failure cases. Formal modeling and automated model checking gave us deep insight in the system functionality. This insight enabled us to create a reliable and trustworthy implementation. With extensive tests we established trust in the reliability of the implementation. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.
[Establishment of Automation System for Detection of Alcohol in Blood].
Tian, L L; Shen, Lei; Xue, J F; Liu, M M; Liang, L J
2017-02-01
To establish an automation system for detection of alcohol content in blood. The determination was performed by automated workstation of extraction-headspace gas chromatography (HS-GC). The blood collection with negative pressure, sealing time of headspace bottle and sample needle were checked and optimized in the abstraction of automation system. The automatic sampling was compared with the manual sampling. The quantitative data obtained by the automated workstation of extraction-HS-GC for alcohol was stable. The relative differences of two parallel samples were less than 5%. The automated extraction was superior to the manual extraction. A good linear relationship was obtained at the alcohol concentration range of 0.1-3.0 mg/mL ( r ≥0.999) with good repeatability. The method is simple and quick, with more standard experiment process and accurate experimental data. It eliminates the error from the experimenter and has good repeatability, which can be applied to the qualitative and quantitative detections of alcohol in blood. Copyright© by the Editorial Department of Journal of Forensic Medicine
Assessing blood vessel perfusion and vital signs through retinal imaging photoplethysmography.
Hassan, Harnani; Jaidka, Sheila; Dwyer, Vincent M; Hu, Sijung
2018-05-01
One solution to the global challenge of increasing ocular disease is a cost-effective technique for rapid screening and assessment. Current ophthalmic imaging techniques, e.g. scanning and ocular blood flow systems, are expensive, complex to operate and utilize invasive contrast agents during assessment. The work presented here demonstrates a simple retinal imaging photoplethysmography (iPPG) system with the potential to provide screening, diagnosis, monitoring and assessment that is non-invasive, painless and radiationless. Time series of individual retinal blood vessel images, captured with an eye fundus camera, are processed using standard filtering, amplitude demodulation and principle component analysis (PCA) methods to determine the values of the heart rate (HR) and respiration rate (RR), which are in compliance with simultaneously obtained measurements using commercial pulse oximetry. It also seems possible that some information on the dynamic changes in oxygen saturation levels ( SpO 2 ) in a retinal blood vessel may also be obtained. As a consequence, the retinal iPPG modality system demonstrates a potential avenue for rapid ophthalmic screening, and even early diagnosis, against ocular disease without the need for fluorescent or contrast agents.
Shimizu, Takashi; Hoshino, Yumi; Miyazaki, Hitoshi; Sato, Eimei
2012-01-01
The female reproductive organs such as ovary, uterus, and placenta are some of the few adult tissues that exhibit regular intervals of rapid growth, and are highly vascularized and have high rates of blood flow. Angiogenesis is a process of vascular growth that is mainly limited to the reproductive system in healthy adult animals. The development of new blood vessels in the ovary and uterus is essential to guarantee the necessary supply of nutrients and hormones. The genetic and molecular mechanisms that control the development of capillary blood vessels in the reproductive organs are beginning to be elucidated. Reproductive organs contain and produce angiogenic factors which may act alone or in concert to regulate the process of vasculature. Vascular endothelial growth factors (VEGFs) and fibroblast growth factor (FGFs) are key factors for vascular system in the reproductive organs. Recent numerous studies reported several roles of VEGFs and FGFs on ovarian and uterine functions. In this review, we focus on the involvement of VEGFs and FGFs as angiogenic factors on reproductive organs and vascular therapy for diseases of reproductive organs using anti-angiogenic agents.
[Innovative technology and blood safety].
Begue, S; Morel, P; Djoudi, R
2016-11-01
If technological innovations are not enough alone to improve blood safety, their contributions for several decades in blood transfusion are major. The improvement of blood donation (new apheresis devices, RFID) or blood components (additive solutions, pathogen reduction technology, automated processing of platelets concentrates) or manufacturing process of these products (by automated processing of whole blood), all these steps where technological innovations were implemented, lead us to better traceability, more efficient processes, quality improvement of blood products and therefore increased blood safety for blood donors and patients. If we are on the threshold of a great change with the progress of pathogen reduction technology (for whole blood and red blood cells), we hope to see production of ex vivo red blood cells or platelets who are real and who open new conceptual paths on blood safety. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
NASA Astrophysics Data System (ADS)
Habibzadeh, Mehdi; Jannesari, Mahboobeh; Rezaei, Zahra; Baharvand, Hossein; Totonchi, Mehdi
2018-04-01
This works gives an account of evaluation of white blood cell differential counts via computer aided diagnosis (CAD) system and hematology rules. Leukocytes, also called white blood cells (WBCs) play main role of the immune system. Leukocyte is responsible for phagocytosis and immunity and therefore in defense against infection involving the fatal diseases incidence and mortality related issues. Admittedly, microscopic examination of blood samples is a time consuming, expensive and error-prone task. A manual diagnosis would search for specific Leukocytes and number abnormalities in the blood slides while complete blood count (CBC) examination is performed. Complications may arise from the large number of varying samples including different types of Leukocytes, related sub-types and concentration in blood, which makes the analysis prone to human error. This process can be automated by computerized techniques which are more reliable and economical. In essence, we seek to determine a fast, accurate mechanism for classification and gather information about distribution of white blood evidences which may help to diagnose the degree of any abnormalities during CBC test. In this work, we consider the problem of pre-processing and supervised classification of white blood cells into their four primary types including Neutrophils, Eosinophils, Lymphocytes, and Monocytes using a consecutive proposed deep learning framework. For first step, this research proposes three consecutive pre-processing calculations namely are color distortion; bounding box distortion (crop) and image flipping mirroring. In second phase, white blood cell recognition performed with hierarchy topological feature extraction using Inception and ResNet architectures. Finally, the results obtained from the preliminary analysis of cell classification with (11200) training samples and 1244 white blood cells evaluation data set are presented in confusion matrices and interpreted using accuracy rate, and false positive with the classification framework being validated with experiments conducted on poor quality blood images sized 320 × 240 pixels. The deferential outcomes in the challenging cell detection task, as shown in result section, indicate that there is a significant achievement in using Inception and ResNet architecture with proposed settings. Our framework detects on average 100% of the four main white blood cell types using ResNet V1 50 while also alternative promising result with 99.84% and 99.46% accuracy rate obtained with ResNet V1 152 and ResNet 101, respectively with 3000 epochs and fine-tuning all layers. Further statistical confusion matrix tests revealed that this work achieved 1, 0.9979, 0.9989 sensitivity values when area under the curve (AUC) scores above 1, 0.9992, 0.9833 on three proposed techniques. In addition, current work shows negligible and small false negative 0, 2, 1 and substantial false positive with 0, 0, 5 values in Leukocytes detection.
An Immunological Fingerprint Differentiates Muscular Lymphatics from Arteries and Veins
Bridenbaugh, Eric A.; Wang, Wei; Srimushnam, Maya; Cromer, Walter E.; Zawieja, Scott D.; Schmidt, Susan E.; Jupiter, Daniel C.; Huang, Hung-Chung; Van Buren, Vincent
2013-01-01
Abstract The principal function of the lymphatic system is to transport lymph from the interstitium to the nodes and then from the nodes to the blood. In doing so lymphatics play important roles in fluid homeostasis, macromolecular/antigen transport and immune cell trafficking. To better understand the genes that contribute to their unique physiology, we compared the transcriptional profile of muscular lymphatics (prenodal mesenteric microlymphatics and large, postnodal thoracic duct) to axillary and mesenteric arteries and veins isolated from rats. Clustering of the differentially expressed genes demonstrated that the lymph versus blood vessel differences were more profound than between blood vessels, particularly the microvessels. Gene ontology functional category analysis indicated that microlymphatics were enriched in antigen processing/presentation, IgE receptor signaling, catabolic processes, translation and ribosome; while they were diminished in oxygen transport, regulation of cell proliferation, glycolysis and inhibition of adenylate cyclase activity by G-proteins. We evaluated the differentially expressed microarray genes/products by qPCR and/or immunofluorescence. Immunofluorescence documented that multiple MHC class II antigen presentation proteins were highly expressed by an antigen-presenting cell (APC) type found resident within the lymphatic wall. These APCs also expressed CD86, a co-stimulatory protein necessary for T-cell activation. We evaluated the distribution and phenotype of APCs within the pre and postnodal lymphatic network. This study documents a novel population of APCs resident within the walls of muscular, prenodal lymphatics that indicates novel roles in antigen sampling and immune responses. In conclusion, these prenodal lymphatics exhibit a unique profile that distinguishes them from blood vessels and highlights the role of the lymphatic system as an immunovascular system linking the parenchymal interstitium, lymph nodes and the blood. PMID:24044756
Cuff-Free Blood Pressure Estimation Using Pulse Transit Time and Heart Rate.
Wang, Ruiping; Jia, Wenyan; Mao, Zhi-Hong; Sclabassi, Robert J; Sun, Mingui
2014-10-01
It has been reported that the pulse transit time (PTT), the interval between the peak of the R-wave in electrocardiogram (ECG) and the fingertip photoplethysmogram (PPG), is related to arterial stiffness, and can be used to estimate the systolic blood pressure (SBP) and diastolic blood pressure (DBP). This phenomenon has been used as the basis to design portable systems for continuously cuff-less blood pressure measurement, benefiting numerous people with heart conditions. However, the PTT-based blood pressure estimation may not be sufficiently accurate because the regulation of blood pressure within the human body is a complex, multivariate physiological process. Considering the negative feedback mechanism in the blood pressure control, we introduce the heart rate (HR) and the blood pressure estimate in the previous step to obtain the current estimate. We validate this method using a clinical database. Our results show that the PTT, HR and previous estimate reduce the estimated error significantly when compared to the conventional PTT estimation approach (p<0.05).
NASA Astrophysics Data System (ADS)
Custer, Jonathan R.; Kariuki, Michael; Beerntsen, Brenda T.; Viator, John A.
2010-02-01
Malaria is a blood borne infection affecting hundreds of millions of people worldwide2. The parasites reproduce within the blood cells, eventually causing their death and lysis. This process releases the parasites into the blood, continuing the cycle of infection. Usually, malaria is diagnosed only after a patient presents symptoms, including high fever, nausea, and, in advanced cases, coma and death. While invading the bloodstream of a host, malaria parasites convert hemoglobin into an insoluble crystal, known as hemozoin. These crystals, approximately several hundred nanometers in size, are contained within red blood cells and white blood cells that ingest free hemozoin in the blood. Thus, infected red blood cells and white blood cells contain a unique optical absorber that can be detected in blood samples using static photoacoustic detection methods. We separated the white blood cells from malaria infected blood and tested it in a photoacoustic set up using a tunable laser system consisting of an optical parametric oscillator pumped by an Nd:YAG laser with pulse duration of 5 ns. Our threshold of detection was 10 infected white blood cells per microliter, which is more sensitive than current diagnosis methods using microscopic analysis of blood.
Lei, Kin Fong; Chen, Kuan-Hao; Tsui, Po-Hsiang; Tsang, Ngan-Ming
2013-01-01
Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity. PMID:24116099
Development of a database and processing method for detecting hematotoxicity adverse drug events.
Shimai, Yoshie; Takeda, Toshihiro; Manabe, Shirou; Teramoto, Kei; Mihara, Naoki; Matsumura, Yasushi
2015-01-01
Adverse events are detected by monitoring the patient's status, including blood test results. However, it is difficult to identify all adverse events based on recognition by individual doctors. We developed a system that can be used to detect hematotoxicity adverse events according to blood test results recorded in an electronic medical record system. The blood test results were graded based on Common Terminology Criteria for Adverse Events (CTCAE) and changes in the blood test results (Up, Down, Flat) were assessed according to the variation in the grade. The changes in the blood test and injection data were stored in a database. By comparing the date of injection and start and end dates of the change in the blood test results, adverse events related to a designated drug were detected. Using this method, we searched for the occurrence of serious adverse events (CTCAE Grades 3 or 4) concerning WBC, ALT and creatinine related to paclitaxel at Osaka University Hospital. The rate of occurrence of a decreased WBC count, increased ALT level and increased creatinine level was 36.0%, 0.6% and 0.4%, respectively. This method is useful for detecting and estimating the rate of occurrence of hematotoxicity adverse drug events.
Improving organisational systems for diabetes care in Australian Indigenous communities.
Bailie, Ross; Si, Damin; Dowden, Michelle; O'Donoghue, Lynette; Connors, Christine; Robinson, Gary; Cunningham, Joan; Weeramanthri, Tarun
2007-05-06
Indigenous Australians experience disproportionately high prevalence of, and morbidity and mortality from diabetes. There is an urgent need to understand how Indigenous primary care systems are organised to deliver diabetes services to those most in need, to monitor the quality of diabetes care received by Indigenous people, and to improve systems for better diabetes care. The intervention featured two annual cycles of assessment, feedback workshops, action planning, and implementation of system changes in 12 Indigenous community health centres. Assessment included a structured review of health service systems and audit of clinical records. Main process of care measures included adherence to guideline-scheduled services and medication adjustment. Main patient outcome measures were HbA1c, blood pressure and total cholesterol levels. There was good engagement of health centre staff, with significant improvements in system development over the study period. Adherence to guideline-scheduled processes improved, including increases in 6 monthly testing of HbA1c from 41% to 74% (Risk ratio 1.93, 95% CI 1.71-2.10), 3 monthly checking of blood pressure from 63% to 76% (1.27, 1.13-1.37), annual testing of total cholesterol from 56% to 74% (1.36, 1.20-1.49), biennial eye checking by a ophthalmologist from 34% to 54% (1.68, 1.39-1.95), and 3 monthly feet checking from 20% to 58% (3.01, 2.52-3.47). Medication adjustment rates following identification of elevated HbA1c and blood pressure were low, increasing from 10% to 24%, and from 13% to 21% respectively at year 1 audit. However, improvements in medication adjustment were not maintained at the year 2 follow-up. Mean HbA1c value improved from 9.3 to 8.9% (mean difference -0.4%, 95% CI -0.7;-0.1), but there was no improvement in blood pressure or cholesterol control. This quality improvement (QI) intervention has proved to be highly acceptable in the Indigenous Australian primary care setting and has been associated with significant improvements in systems and processes of care and some intermediate outcomes. However, improvements appear to be limited by inadequate attention to abnormal clinical findings and medication management. Greater improvement in intermediate outcomes may be achieved by specifically addressing system barriers to therapy intensification through more effective engagement of medical staff in QI activities and/or greater use of nurse-practitioners.
Surase, P V; Nataraj, G; Pattamadai, K; Mehta, P R; Pazare, A R; Agarwal, M C; Nanavati, R N
2016-01-01
Comparison of conventional blood culture with BACTEC 9050 for rate and time to detection of microorganisms. A prospective study was carried out in a multispecialty tertiary care teaching hospital. A total of 835 paired specimens (797 blood and 38 nonblood specimens) were collected and processed according to standard microbiological procedures by both conventional method as well as by BACTEC 9050 automated culture system. Clinical details of patients were recorded. Data were analyzed for time to detection and isolation rate by the two systems and compared. Overall culture positivity for BACTEC 9050 and the conventional system was 32% and 19.88%, respectively. Eighty-five demonstrated concordant growth, 136 specimens were culture positive by BACTEC only, and 38 specimens were culture positive by conventional only. Twelve contaminants in BACTEC and nine contaminants in conventional system were detected. Using BACTEC 9050, higher isolation was observed for Acinetobacter spp., coagulase negative Staphylococcus spp., Streptococcus spp., and Candida spp. A total of 410 patients were on antimicrobial treatment and culture positivity was significantly higher with BACTEC 9050 (P < 0.0001). There was a significant difference in the mean time to detection with BACTEC 9050 recovering 86.8% of isolates within 48 h (P < 0.0001). Although BACTEC 9050 demonstrated a significantly higher recovery of microorganisms from blood, an appropriately performed conventional blood culture can facilitate the choice of therapy.
Lin, Yu-Chung; Tsai, Lin-Wei; Perevedentseva, Elena; Chang, Hsin-Hou; Lin, Ching-Hui; Sun, Der-Shan; Lugovtsov, Andrei E; Priezzhev, Alexander; Mona, Jani; Cheng, Chia-Liang
2012-10-01
Nanodiamond has been proven to be biocompatible and proposed for various biomedical applications. Recently, nanometer-sized diamonds have been demonstrated as an effective Raman/fluorescence probe for bio-labeling, as well as, for drug delivery. Bio-labeling/drug delivery can be extended to the human blood system, provided one understands the interaction between nanodiamonds and the blood system. Here, the interaction of nanodiamonds (5 and 100 nm) with human red blood cells (RBC) in vitro is discussed. Measurements have been facilitated using Raman spectroscopy, laser scanning fluorescence spectroscopy, and laser diffractometry (ektacytometry). Data on cell viability and hemolytic analysis are also presented. Results indicate that the nanodiamonds in the studied condition do not cause hemolysis, and the cell viability is not affected. Importantly, the oxygenation/deoxygenation process was not found to be altered when nanodiamonds interacted with the RBC. However, the nanodiamond can affect some RBC properties such as deformability and aggregation in a concentration dependent manner. These results suggest that the nanodiamond can be used as an effective bio-labeling and drug delivery tool in ambient conditions, without complicating the blood's physiological conditions. However, controlling the blood properties including deformability of RBCs and rheological properties of blood is necessary during treatment.
Perspectives on Systems Modeling of Human Peripheral Blood Mononuclear Cells
Sen, Partho; Kemppainen, Esko; Orešič, Matej
2018-01-01
Human peripheral blood mononuclear cells (PBMCs) are the key drivers of the immune responses. These cells undergo activation, proliferation and differentiation into various subsets. During these processes they initiate metabolic reprogramming, which is coordinated by specific gene and protein activities. PBMCs as a model system have been widely used to study metabolic and autoimmune diseases. Herein we review various omics and systems-based approaches such as transcriptomics, epigenomics, proteomics, and metabolomics as applied to PBMCs, particularly T helper subsets, that unveiled disease markers and the underlying mechanisms. We also discuss and emphasize several aspects of T cell metabolic modeling in healthy and disease states using genome-scale metabolic models. PMID:29376056
Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong; Kim, Hee Chan
2017-01-01
The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method as an automated white blood cell differential count system.
Choi, Jin Woo; Ku, Yunseo; Yoo, Byeong Wook; Kim, Jung-Ah; Lee, Dong Soon; Chai, Young Jun; Kong, Hyoun-Joong
2017-01-01
The white blood cell differential count of the bone marrow provides information concerning the distribution of immature and mature cells within maturation stages. The results of such examinations are important for the diagnosis of various diseases and for follow-up care after chemotherapy. However, manual, labor-intensive methods to determine the differential count lead to inter- and intra-variations among the results obtained by hematologists. Therefore, an automated system to conduct the white blood cell differential count is highly desirable, but several difficulties hinder progress. There are variations in the white blood cells of each maturation stage, small inter-class differences within each stage, and variations in images because of the different acquisition and staining processes. Moreover, a large number of classes need to be classified for bone marrow smear analysis, and the high density of touching cells in bone marrow smears renders difficult the segmentation of single cells, which is crucial to traditional image processing and machine learning. Few studies have attempted to discriminate bone marrow cells, and even these have either discriminated only a few classes or yielded insufficient performance. In this study, we propose an automated white blood cell differential counting system from bone marrow smear images using a dual-stage convolutional neural network (CNN). A total of 2,174 patch images were collected for training and testing. The dual-stage CNN classified images into 10 classes of the myeloid and erythroid maturation series, and achieved an accuracy of 97.06%, a precision of 97.13%, a recall of 97.06%, and an F-1 score of 97.1%. The proposed method not only showed high classification performance, but also successfully classified raw images without single cell segmentation and manual feature extraction by implementing CNN. Moreover, it demonstrated rotation and location invariance. These results highlight the promise of the proposed method as an automated white blood cell differential count system. PMID:29228051
Lemaire, Clementine A; Liu, Sean Z; Wilkerson, Charles L; Ramani, Vishnu C; Barzanian, Nasim A; Huang, Kuo-Wei; Che, James; Chiu, Michael W; Vuppalapaty, Meghah; Dimmick, Adam M; Carlo, Dino Di; Kochersperger, Michael L; Crouse, Steve C; Jeffrey, Stefanie S; Englert, Robert F; Hengstler, Stephan; Renier, Corinne; Sollier-Christen, Elodie
2018-02-01
Tumor tissue biopsies are invasive, costly, and collect a limited cell population not completely reflective of patient cancer cell diversity. Circulating tumor cells (CTCs) can be isolated from a simple blood draw and may be representative of the diverse biology from multiple tumor sites. The VTX-1 Liquid Biopsy System was designed to automate the isolation of clinically relevant CTC populations, making the CTCs available for easy analysis. We present here the transition from a cutting-edge microfluidic innovation in the lab to a commercial, automated system for isolating CTCs directly from whole blood. As the technology evolved into a commercial system, flexible polydimethylsiloxane microfluidic chips were replaced by rigid poly(methyl methacrylate) chips for a 2.2-fold increase in cell recovery. Automating the fluidic processing with the VTX-1 further improved cancer cell recovery by nearly 1.4-fold, with a 2.8-fold decrease in contaminating white blood cells and overall improved reproducibility. Two isolation protocols were optimized that favor either the cancer cell recovery (up to 71.6% recovery) or sample purity (≤100 white blood cells/mL). The VTX-1's performance was further tested with three different spiked breast or lung cancer cell lines, with 69.0% to 79.5% cell recovery. Finally, several cancer research applications are presented using the commercial VTX-1 system.
Fabrication of subcutaneous veins phantom for vessel visualization system
NASA Astrophysics Data System (ADS)
Cheng, Kai; Narita, Kazuyuki; Morita, Yusuke; Nakamachi, Eiji; Honda, Norihiro; Awazu, Kunio
2013-09-01
The technique of subcutaneous veins imaging by using NIR (Near Infrared Radiation) is widely used in medical applications, such as the intravenous injection and the blood sampling. In the previous study, an automatic 3D blood vessel search and automatic blood sampling system was newly developed. In order to validate this NIR imaging system, we adopted the subcutaneous vein in the human arm and its artificial phantom, which imitate the human fat and blood vessel. The human skin and subcutaneous vein is characterized as the uncertainty object, which has the individual specificity, non-accurate depth information, non-steady state and hardly to be fixed in the examination apparatus. On the other hand, the conventional phantom was quite distinct from the human's characteristics, such as the non-multilayer structure, disagreement of optical property. In this study, we develop a multilayer phantom, which is quite similar with human skin, for improvement of NIR detection system evaluation. The phantom consists of three layers, such as the epidermis layer, the dermis layer and the subcutaneous fat layer. In subcutaneous fat layer, we built a blood vessel. We use the intralipid to imitate the optical scattering characteristics of human skin, and the hemoglobin and melanin for the optical absorption characteristics. In this study, we did two subjects. First, we decide the fabrication process of the phantom. Second, we compared newly developed phantoms with human skin by using our NIR detecting system, and confirm the availability of these phantoms.
Damato, Charlotte; Rickard, Dana
2015-03-01
As part of a strategic quality improvement plan, laboratory management at Sarasota Memorial Health Care System (SMHCS) focused its efforts on improving preanalytical work flow and blood collection processes-both negatively affected by hemolyzed specimens. When hemolysis is detected in a blood specimen, blood may need to be re-collected, resulting in bottlenecks and rework all along the value stream. From July through December 2009, hemolysis averaged 9.8% in the Emergency Care Center (ECC) and 3.4% housewide. The goal was set to reduce hemolysis to 2%. The project team identified hemolysis as one of seven factors contributing to non-value-added activities and bottlenecks in blood collection and preanalytical processes. Observations and interviews helped to identify error-prone practices and process variation. To verify the root causes of hemolysis, the findings were compared against best practices. The team developed a housewide protocol, standardized collection processes, created competency-based training, and enhanced ECC hiring practices. During December 2010-March 2011, following initial housewide interventions and ECC self-sustaining solutions, ECC hemolysis decreased by 91%-from 9.8% (423 hemolyzed/4,295 collected) to 0.88% (58 hemolyzed/6,560 collected). Housewide hemolysis decreased by 59%-from 3.4% (2,046 hemolyzed/60,307 collected) to 1.39% (619 hemolyzed/44,528 collected). Since the project, hemolysis has continued to trend downward; the mean percentage has consistently been < .05% for the ECC and < 1% housewide. Lean-Six Sigma tools helped to pinpoint hemolysis as a key inefficiency in blood collection and preanalytical work flow. Although focused on the ECC, the project team standardized blood collection practices and instituted quality devices to achieve hemolysis reductions housewide.
Preanalytical Nonconformity Management Regarding Primary Tube Mixing in Brazil.
Lima-Oliveira, Gabriel; Cesare Guidi, Gian; Guimaraes, Andre Valpassos Pacifici; Abol Correa, Jose; Lippi, Giuseppe
2017-01-01
The multifaceted clinical laboratory process is divided in three essential phases: the preanalytical, analytical and postanalytical phase. Problems emerging from the preanalytical phase are responsible for more than 60% of laboratory errors. This report is aimed at highlighting and discussing nonconformity (e.g., nonstandardized procedures) in primary blood tube mixing immediately after blood collection by venipuncture with evacuated tube systems. From January 2015 to December 2015, fifty different laboratory quality managers from Brazil were contacted to request their internal audit reports on nonconformity regarding primary blood tube mixing immediately after blood collection by venipuncture performed using evacuated tube systems. A minority of internal audits (i.e., 4%) concluded that evacuated blood tubes were not accurately mixed after collection, whereas more than half of them reported that evacuated blood tubes were vigorously mixed immediately after collection, thus magnifying the risk of producing spurious hemolysis. Despite the vast ma jority of centers declaring that evacuated blood tubes were mixed gently and carefully, the overall number of inversions was found to be different from that recommended by the manufacturer. Since the turbulence generated by the standard vacuum pressure inside the primary evacuated tubes seems to be sufficient for providing solubilization, mixing and stabilization between additives and blood during venipuncture, avoidance of primary tube mixing probably does not introduce a major bias in tests results and may not be considered a nonconformity during audits for accreditation.
NASA Astrophysics Data System (ADS)
Yang, Xue; Wang, Hongbo; Sun, Li; Yu, Hongnian
2015-03-01
To develop a robot system for minimally invasive surgery is significant, however the existing minimally invasive surgery robots are not applicable in practical operations, due to their limited functioning and weaker perception. A novel wire feeder is proposed for minimally invasive vascular interventional surgery. It is used for assisting surgeons in delivering a guide wire, balloon and stenting into a specific lesion location. By contrasting those existing wire feeders, the motion methods for delivering and rotating the guide wire in blood vessel are described, and their mechanical realization is presented. A new resistant force detecting method is given in details. The change of the resistance force can help the operator feel the block or embolism existing in front of the guide wire. The driving torque for rotating the guide wire is developed at different positions. Using the CT reconstruction image and extracted vessel paths, the path equation of the blood vessel is obtained. Combining the shapes of the guide wire outside the blood vessel, the whole bending equation of the guide wire is obtained. That is a risk criterion in the delivering process. This process can make operations safer and man-machine interaction more reliable. A novel surgery robot for feeding guide wire is designed, and a risk criterion for the system is given.
A data driven nonlinear stochastic model for blood glucose dynamics.
Zhang, Yan; Holt, Tim A; Khovanova, Natalia
2016-03-01
The development of adequate mathematical models for blood glucose dynamics may improve early diagnosis and control of diabetes mellitus (DM). We have developed a stochastic nonlinear second order differential equation to describe the response of blood glucose concentration to food intake using continuous glucose monitoring (CGM) data. A variational Bayesian learning scheme was applied to define the number and values of the system's parameters by iterative optimisation of free energy. The model has the minimal order and number of parameters to successfully describe blood glucose dynamics in people with and without DM. The model accounts for the nonlinearity and stochasticity of the underlying glucose-insulin dynamic process. Being data-driven, it takes full advantage of available CGM data and, at the same time, reflects the intrinsic characteristics of the glucose-insulin system without detailed knowledge of the physiological mechanisms. We have shown that the dynamics of some postprandial blood glucose excursions can be described by a reduced (linear) model, previously seen in the literature. A comprehensive analysis demonstrates that deterministic system parameters belong to different ranges for diabetes and controls. Implications for clinical practice are discussed. This is the first study introducing a continuous data-driven nonlinear stochastic model capable of describing both DM and non-DM profiles. Copyright © 2015 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
Sadowska, Joanna; Kuchlewska, Magdalena
2011-01-01
Metabolic processes of food additives which are "exogenous xenobiotics" are catalysed, primarily, by enzymes located in microsomes of hepatocytes affiliated to P-450 cytochrome superfamily, containing iron. The aim of the study was to investigate the effect of diet composition and selected food additives on the erythrocyte system and iron metabolism in peripheral blood of male rats. The experiment was carried out on 30 male rats sorted into three equinumerous groups. For drinking animals received pure, settled tap water, animals from group III were receiving additionally an aqueous solution of sodium (nitrate), potassium nitrite, benzoic acid, sorbic acid and monosodium glutamate. Ascertained a significant effect of changes in diet composition on the increase in hematocrit marker value and the count of red blood cells in blood of animals examined. Used food additives diminished hemoglobin concentration, hematocrit value and red blood cell count, diminishing also iron concentration in serum, the total iron binding capacity and transferrin saturation with iron. Analysis of the results allowed ascertain adverse changes in values of the erythrocytic system markers, occurring under the influence of the applied mixture of food additives. Used food additives change the iron metabolism, most likely from the necessity of applied xenobiotics biotransformation by heme-containing monoxygenases of P-450 cytochrome.
Separation of whole blood into plasma and red cells by using a hollow-fibre filtration system.
Hornsey, V S; McColl, K; Drummond, O; Prowse, C V
2005-08-01
The aim of this study was to assess the separation of whole blood into red cells and plasma by using the Sangofer device, which is a gravity-fed, hollow-fibre system. The components would then be compared with those produced by the use of more elaborate technical equipment. Ten whole-blood units were leucoreduced by using a WBF2 filter and immediately separated into red cells and plasma by using the Sangofer blood-separation device. Red cells were stored in additive solution and tested on days 1 and 42. The plasma was assayed for levels of various coagulation factors and for markers of both coagulation and complement activation. The red-cell parameters were similar to those obtained when routine centrifugation methods were used. The filter did not cause haemolysis. Levels of plasma factor VIII and factor XI were lower than those seen in routinely produced leucoreduced plasma units but there was no evidence of activation of the coagulation and complement systems. The Sangofer device is simple and straightforward to use and eliminates the need for both centrifugation and automated separation steps during the processing of whole blood into red cells and plasma components. Minor changes are required to make the procedure easier to incorporate into routine use.
[Interest of the cholinesterase assay during organophosphate poisonings].
Jalady, A-M; Dorandeu, F
2013-12-01
Cholinesterases are the main targets of organophosphorus compounds. The two enzymes present in the blood (butyrylcholinesterase, BChE; acetylcholinesterase, AChE) are biomarkers of their systemic toxicity. Activity of the plasma BChE is very often determined as it allows a rapid diagnostic of poisoning and is a marker of the persistence of the toxicant in the blood. The activity of the red blood cell AChE gives a better picture of the synaptic inhibition in the nervous system but the assay is less commonly available in routine laboratories. Better biomarker of the exposure, it allows a diagnosis of the severity of the poisoning and helps to assess the efficacy of oxime therapy. Besides the practical aspects of blood collection and sample processing, and the interpretation of the assays, this review stresses the complementarity of both enzyme assays and recalls their crucial interest for the confirmation of poisoning with an organophosphorus in a situation of war or terrorist attack and for the monitoring of occupational exposures. Copyright © 2013. Published by Elsevier SAS.
Ahmed, Heba A; MacLeod, Ewan T; Hide, Geoff; Welburn, Susan C; Picozzi, Kim
2011-05-07
Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach.
Beak, Carla Pereira; Chargé, Sophie B; Isasi, Rosario; Knoppers, Bartha M
2015-05-01
In 2013 Canadian Blood Services (CBS) launched the National Public Cord Blood Bank (NPCBB), a program to collect, process, test, and store cord blood units donated for use in transplantation. A key component of the creation of the NPCBB is the establishment of a program that enables cord blood not suitable for banking or transplantation to be used for biomedical research purposes. Along with the development of processes and policies to manage the NPCBB and the cord blood research program, CBS-in collaboration with researchers from the Stem Cell Network-have also developed educational tools to provide relevant information for target audiences to aid implementation and operation. We describe here one of these tools, the REB Primer on Research and Cord Blood Donation (the Primer), which highlights key ethical and legal considerations and identifies Canadian documents that are relevant to the use of cord blood in biomedical research. The Primer also introduces the NPCBB and describes the systems CBS is implementing to address ethical issues. The Primer is intended to assist research ethics boards in evaluating the ethical acceptability of research protocols, to facilitate harmonized decision-making by providing a common reference, and to highlight the role of research ethics boards in governance frameworks. With the Primer we hope to illustrate how the development of such educational tools can facilitate the ethical implementation and governance of programs related to stem cell research in Canada and abroad.
Comparison of blood specimens from plain and gel vacuum blood collection tubes.
Wiwanitkit, V
2001-05-01
This study was set in the Division of Laboratory Medicine, Chulalongkorn Hospital. All 2,000 blood specimens were randomly collected using evacuated blood collection by plain or gel vacuum tubes. After collection, each specimen was considered and judged using criteria of specimen rejection to determine how proper the specimen presentations were. All data were reviewed, collected and interpreted. It revealed that there were only 20 (1%) improper specimens and all were improper in quality. There was no significant difference between the ratio of improper specimens in both groups (P > 0.30). From this study, it revealed that efficacy of both types of vacuum tubes was not different. The new gel vacuum tube seems to be an effective tool in the evacuated blood collection system due to its advantage in reduction of time in specimen processing.
Malsby, Robert F; Quesada, Jose; Powell-Dunford, Nicole; Kinoshita, Ren; Kurtz, John; Gehlen, William; Adams, Colleen; Martin, Dustin; Shackelford, Stacy
2013-07-01
U.S. Army flight medics performed a process improvement initiative of 15 blood product transfusions on select Category A (Urgent) helicopter evacuation casualties meeting approved clinical indications for transfusion. These transfusions were initiated from point of injury locations aboard MEDEVAC aircraft originating from one of two locations in southern Afghanistan. All flight medics executing the transfusions were qualified through a standardized and approved program of instruction, which included day and night skills validation, and a 90% or higher written examination score. There was no adverse reaction or out-of-standard blood product temperature despite hazardous conditions and elevated cabin temperatures. All casualties within a 10-minute flight time who met clinical indications were transfused. Utilization of a standard operating procedure with strict handling and administration parameters, a rigorous training and qualification program, an elaborate cold chain system, and redundant documentation of blood product units ensured that flight medic initiated transfusions were safe and effective. Research study is needed to refine the indications for prehospital blood transfusion and to determine the effect on outcomes in severely injured trauma patients. Reprint & Copyright © 2013 Association of Military Surgeons of the U.S.
High sensitive pulse oximeter-spectrophotometer for laser-optical dosimetry in biology and medicine
NASA Astrophysics Data System (ADS)
Asimov, M. M.; Asimov, R. M.; Rubinov, A. N.; Mamilov, S. A.; Plaksiy, Yu. S.
2006-03-01
High sensitive multi channel pulse oxymeter - spectrophotometer for control of the local tissue oxygen saturation is presented. Due to an original method of data storing and processing the accuracy of measurements 3-4 times are increased in compare with similar systems. This system is used for registration of the local changes of arterial blood saturation with oxygen under effect of low intensity laser radiation. It is shown that the photodissociation of oxyhemoglobin in cutaneous blood vessels play a dominant role in the mechanism of biostimulating and therapeutic effect of low intensity laser radiation. The results of experimental investigation in vivo the dependence of arterial oxygen blood saturation on temperature and the wavelength of laser radiation are presented. It is suggested that dosimetry for laser therapy could be base on regulation of local concentration of free oxygen in tissue.
Dumont, Larry J; Cancelas, Jose A; Maes, Lou Ann; Rugg, Neeta; Whitley, Pamela; Herschel, Louise; Siegal, Alan H; Szczepiorkowski, Zbigniew M; Hess, John R; Zia, Majid
2015-03-01
Overnight, room temperature hold (ONH) of whole blood before component processing offers several benefits. This study evaluated the storage and in vivo recovery characteristics of ONH red blood cells (RBCs) stored in additive solution-7 (AS-7). We conducted a three-center, three-arm evaluation of a new blood collection system with AS-7 compared to leukoreduced RBCs processed within 8 hours and stored in AS-1 (control). Whole blood (500 ± 50 mL) from healthy research subjects (n = 240) was held at room temperature 0 to 2 hours, 6 to 8 hours, or ONH (18-24 hr) before component processing and storage at 1 to 6 °C. RBCs were evaluated on Days 42 and 56 with a panel of in vitro assays. Subsets of the AS-7-stored RBCs were evaluated for (51) Cr 24-hour in vivo recovery and long-term survival. Adenosine triphosphate (ATP) levels in ONH RBCs were not different than AS-7 RBCs prepared within 8 hours. ATP was higher in the ONH group on Day 42 than control, and ATP was maintained in all AS-7 groups through Day 56. ONH units had 0.36 ± 0.14% on Day 42 hemolysis (60/60 < 0.8%), and 0.54 ± 0.22% on Day 56 (10/60 > 0.8%, 2/60 > 1%). In vivo recoveries of stored RBCs were not different between the AS-7 arms at 42 days (p = 0.16; 27/27 ONH units > 75%), but the Day 56 ONH was significantly less than ONH on Day 42 (p = 0.008; 7/28 < 75%). Overnight hold of whole blood at room temperature before component processing meets current regulatory requirements when RBCs are stored up to 42 days in AS-7. © 2014 AABB.
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2012 CFR
2012-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2011 CFR
2011-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2014 CFR
2014-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
21 CFR 864.9100 - Empty container for the collection and processing of blood and blood components.
Code of Federal Regulations, 2013 CFR
2013-04-01
... of blood and blood components. 864.9100 Section 864.9100 Food and Drugs FOOD AND DRUG ADMINISTRATION... Used In Establishments That Manufacture Blood and Blood Products § 864.9100 Empty container for the collection and processing of blood and blood components. (a) Identification. An empty container for the...
[Organization of safe cost-effective blood transfusion: experience APHM-EFSAM].
Ferrera-Tourenc, V; Dettori, I; Chiaroni, J; Lassale, B
2013-03-01
Blood transfusion safety depends on strict compliance with each step of a process beginning with the order for labile blood products and related immunohematologic testing and ending with administration and follow-up of the receiver. This process is governed by stringent regulatory texts and guidelines. Despite precautions, processing errors are still reported. Analysis of incident reports shows that the most common cause involves patient identification and that most errors occur at two levels, i.e. the entry of patient information and management of multiple regulatory crosschecks and record-keeping using different systems. The purpose of this report is to describe the collaborative approach implemented by the Établissement français du Sang Alpes-Méditerranée (EFSAM) and the Assistance publique des Hôpitaux de Marseille (APHM) to secure the blood transfusion process and protect interfaces while simplifying and facilitating exchanges. Close cooperation has had a threefold impact with simplification of administration, improvement of experience feedback, and better management of test ordering. The organization implemented between the two institutions has minimized document redundancy and interfaces between immunohematologic testing and delivery. Collaboration based on experience feedback has improved the level of quality and cost control. In the domain of blood transfusion safety, the threshold of 10(-5) has been reached with regard to the risk of ABO errors in the distribution concentrated red cells (CRC). In addition, this collaborative organization has created further opportunity for improvement by deploying new methods to identify simplification measures and by controlling demand and usage. Copyright © 2013 Elsevier Masson SAS. All rights reserved.
Ginzburg, Yelena; Kessler, Debra; Narici, Manlio; Caltabiano, Melinda; Rebosa, Mark; Strauss, Donna; Shaz, Beth
2013-10-01
The past few decades have seen a resurgence of interest in leukapheresis products to improve the survival of infected patients with neutropenia. These products have a short shelf life and require donor stimulation with dexamethasone before collection. Additionally, a system with good communications and logistical support is essential. A recent survey of blood centers in North America revealed that the majority of centers collecting leukapheresis products use steroid-stimulated donors. The survey results suggested that an analysis of the process and potential process improvement would be of interest to the transfusion medicine community. Data from 2008 to 2011 regarding donor selection, donor dexamethasone stimulation, leukapheresis collection, and correlations between potentially pertinent variables for process improvement were analyzed. Results from an analysis of cost are also included. We evaluate 432 leukapheresis donations and demonstrate correlations between 1) pre- and poststimulation white blood cell (WBC) count (p<0.0001), 2) interval (donor stimulation to collection) and poststimulation WBC count (p<0.0001), and 3) poststimulation WBC count and leukapheresis product granulocyte yield (p<0.0001). Significant improvement in granulocyte quality and yield can be accomplished in dexamethasone-stimulated donors, by selecting eligible donors with relatively high normal prestimulation WBC counts and/or previously good responses to dexamethasone, increasing the duration between dexamethasone stimulation and granulocyte collection, and maintaining optimal hematocrit (5%-10%) in granulocyte collections. Because the majority of surveyed blood centers collecting stimulated granulocytes use steroids alone, modifications presented here may prove useful. Further assessment of correlation between granulocyte yield and clinical outcome will await results of additional studies. © 2012 American Association of Blood Banks.
Automatic analysis of microscopic images of red blood cell aggregates
NASA Astrophysics Data System (ADS)
Menichini, Pablo A.; Larese, Mónica G.; Riquelme, Bibiana D.
2015-06-01
Red blood cell aggregation is one of the most important factors in blood viscosity at stasis or at very low rates of flow. The basic structure of aggregates is a linear array of cell commonly termed as rouleaux. Enhanced or abnormal aggregation is seen in clinical conditions, such as diabetes and hypertension, producing alterations in the microcirculation, some of which can be analyzed through the characterization of aggregated cells. Frequently, image processing and analysis for the characterization of RBC aggregation were done manually or semi-automatically using interactive tools. We propose a system that processes images of RBC aggregation and automatically obtains the characterization and quantification of the different types of RBC aggregates. Present technique could be interesting to perform the adaptation as a routine used in hemorheological and Clinical Biochemistry Laboratories because this automatic method is rapid, efficient and economical, and at the same time independent of the user performing the analysis (repeatability of the analysis).
[The design and applications of a non-invasive intelligent detector for cardiovascular functions].
Li, Feng; Xing, Wu; Chen, Ming-zhi; Shang, Huai
2006-05-01
An apparatus based on a high sensitive sensor which detects cardiovascular functions is introduced in this paper. Some intelligent detecting technologies, such as syntactic pattern recognition and a medical expert system are used in this detector. Its embedded single-chip microcomputer processes and analyzes pulse signals for gaining automatically the parameters about heart, blood vessel and blood etc., so as to get the health evaluation, correct medical diagnosis and prediction of cardiovascular diseases.
Proteins at the Biomaterial Electrolyte Interface
NASA Astrophysics Data System (ADS)
Tengvall, Pentti
2005-03-01
Proteins adsorb rapidly onto solid and polymeric surfaces because the association process is in the vast majority of cases energetically favourable, i.e. exothermic. The most common exceptions to this rule are hydrophilic interfaces with low net charge and high mobility, e.g. immobilized PEGs. Current research in the research area tries to understand and control unwanted and wanted adsorption by studying the adsorption kinetics, protein surface binding specificity, protein exchange at interfaces, and surface protein repulsion mechanisms. In blood plasma model systems humoral cascade reactions such as surface mediated coagulation and immune complement raise considerable interest due to the immediate association to blood compatibility, and in tissue applications the binding between surfaces and membrane receptors in cells and tissues. Thus, the understanding of interfacial events at the protein level is of large importance in applications such as blood and tissue contacting biomaterials, in vitro medical and biological diagnostics, food industry and in marine anti-fouling technology. Well described consequences of adsorption are a lowered system energy, increased system entropy, irreversible binding, conformational changes, specific surface/protein interactions, and in biomedical materials applications surface opsonization followed by cell-surface interactions and a host tissue response. This lecture will deal with some mechanisms known to be of importance for the adsorption processes, such as the influence of surface chemistry and surface energy, the composition of the protein solution, the Vroman effect, and residence time. Examples will be shown from ellipsometric experiments using different model surfaces in single/few protein solutions, and specific attention be given to blood serum and plasma experiments on coagulation and immune complement at interfaces.
Light scattering method to measure red blood cell aggregation during incubation
NASA Astrophysics Data System (ADS)
Grzegorzewski, B.; Szołna-Chodór, A.; Baryła, J.; DreŻek, D.
2018-01-01
Red blood cell (RBC) aggregation can be observed both in vivo as well as in vitro. This process is a cause of alterations of blood flow in microvascular network. Enhanced RBC aggregation makes oxygen and nutrients delivery difficult. Measurements of RBC aggregation usually give a description of the process for a sample where the state of a solution and cells is well-defined and the system reached an equilibrium. Incubation of RBCs in various solutions is frequently used to study the effects of the solutions on the RBC aggregation. The aggregation parameters are compared before and after incubation while the detailed changes of the parameters during incubation remain unknown. In this paper we have proposed a method to measure red blood cell aggregation during incubation based on the well-known technique where backscattered light is used to assess the parameters of the RBC aggregation. Couette system consisting of two cylinders is adopted in the method. The incubation is observed in the Couette system. In the proposed method following sequence of rotations is adapted. Two minutes rotation is followed by two minutes stop. In this way we have obtained a time series of back scattered intensity consisting of signals respective for disaggregation and aggregation. It is shown that the temporal changes of the intensity manifest changes of RBC aggregation during incubation. To show the ability of the method to assess the effect of incubation time on RBC aggregation the results are shown for solutions that cause an increase of RBC aggregation as well as for the case where the aggregation is decreased.
Shim, Sangjo; Gascoyne, Peter; Noshari, Jamileh; Stemke Hale, Katherine
2013-01-01
Metastatic disease results from the shedding of cancer cells from a solid primary tumor, their transport through the cardiovascular system as circulating tumor cells (CTCs) and their engraftment and growth at distant sites. Little is known about the properties and fate of tumor cells as they leave their growth site and travel as single cells. We applied analytical dielectrophoretic field-flow fractionation (dFFF) to study the membrane capacitance, density and hydrodynamic properties together with the size and morphology of cultured tumor cells after they were harvested and placed into single cell suspensions. After detachment, the tumor cells exhibited biophysical properties that changed with time through a process of cytoplasmic shedding whereby membrane and cytoplasm were lost. This process appeared to be distinct from the cell death mechanisms of apoptosis, anoikis and necrosis and it may explain why multiple phenotypes are seen among CTCs isolated from patients and among the tumor cells obtained from ascitic fluid of patients. The implications of dynamic biophysical properties and cytoplasmic loss for CTC migration into small blood vessels in the circulatory system, survival and gene expression are discussed. Because the total capacitance of tumor cells remained higher than blood cells even after they had shed cytoplasm, dFFF offers a compelling, antibody-independent technology for isolating viable CTCs from blood even when they are no larger than peripheral blood mononuclear cells. PMID:21691666
Kimura, Joe; DaSilva, Karen; Marshall, Richard
2008-02-01
The increasing prevalence of chronic illnesses in the United States requires a fundamental redesign of the primary care delivery system's structure and processes in order to meet the changing needs and expectations of patients. Population management, systems-based practice, and planned chronic illness care are 3 potential processes that can be integrated into primary care and are compatible with the Chronic Care Model. In 2003, Harvard Vanguard Medical Associates, a multispecialty ambulatory physician group practice based in Boston, Massachusetts, began implementing all 3 processes across its primary care practices. From 2004 to 2006, the overall diabetes composite quality measures improved from 51% to 58% for screening (HgA1c x 2, low-density lipoprotein, blood pressure in 12 months) and from 13% to 17% for intermediate outcomes (HgA1c
NASA Astrophysics Data System (ADS)
Mulawarman, AANB; Arsana, M. E.; Temaja, I. W.; Sukadana, IBP
2018-01-01
Coconut oil extracted from the coconut milk obtained from fresh coconuts s often called virgin coconut oil (VCO). VCO is beneficial to health as an anti-oxidant and can lower HDL cholesterol in the blood while increasing blood LDL levels. In Indonesia most of VCO being produced on a small scale of home industries. Its production capacity still needs to be increased by improving production processes and implementing an appropriate technology accordingly. This research aims to conduct a study on making small-scale production machinery needed to produce VCO with reduced production time and improved quality of VCO in accordance with ISO 7381 quality criteria. The experimental results of the VCO machine has been develop and tested show good Coefficient of Performance of the system in amount of 3.93 and 2.8 for heating and cooling system respectively. Temperature of the VCO cooling chamber can be maintained in the range of 8°C to 10°C, as well as for heating, the reactor temperature can be maintained from 39°C to 42°C. The expected goal of this research developing a prototype of VCO production machine was done with ability to provide more efficient production process able to increase volume of VCO result by 23%.
Kieninger, M; Zech, N; Mulzer, Y; Bele, S; Seemann, M; Künzig, H; Schneiker, A; Gruber, M
2015-05-01
Point of care testing with blood gas analysis (BGA) is an important factor for intensive care medicine. Continuous efforts to optimize workflow, improve safety for the staff and avoid preanalytical mistakes are important and should reflect quality management standards. In a prospective observational study it was investigated whether the implementation of a new system for BGA using labeled syringes and automated processing of the specimens leads to improvements compared to the previously used procedure. In a 4-week test period the time until receiving the final results of the BGA with the standard method used in the clinical routine (control group) was compared to the results in a second 4-week test period using the new labeled syringes and automated processing of the specimens (intervention group). In addition, preanalytical mistakes with both systems were checked during routine daily use. Finally, it was investigated whether a delay of 10 min between taking and analyzing the blood samples alters the results of the BGA. Preanalytical errors were frequently observed in the control group where non-deaerated samples were recorded in 87.3 % but in the intervention group almost all samples (98.9 %) were correctly deaerated. Insufficient homogenization due to omission of manual pivoting was seen in 83.2 % in the control group and in 89.9 % in the intervention group; however, in the intervention group the samples were homogenized automatically during the further analytical process. Although a survey among the staff revealed a high acceptance of the new system and a subjective improvement of workflow, a measurable gain in time after conversion to the new procedure could not be seen. The mean time needed for a complete analysis process until receiving the final results was 244 s in the intervention group and 201 s in the control group. A 10-min delay between taking and analyzing the blood samples led to a significant and clinically relevant elevation of the values for partial pressure of oxygen (pO2) in both groups compared to the results when analyzing the samples immediately (118.4 vs. 148.6 mmHg in the control group and 115.3 vs. 123.7 mmHg in the intervention group). When using standard syringes the partial pressure of carbon dioxide (pCO2) was significantly lower (40.5 vs. 38.3 mmHg) whereas no alterations were seen when using the labeled syringes. The implementation of a new BGA system with labeled syringes and automated processing of the specimens was possible without any difficulties under daily clinical routine conditions in this 10-bed intensive care unit (ICU). A gain of time could not be measured but a reduction in preanalytical errors using the labeled syringes with automated processing was found. Delayed analysis of blood samples can lead to significant changes in pO2 and pCO2 depending on the type of syringe used.
Computer algorithms in the search for unrelated stem cell donors.
Steiner, David
2012-01-01
Hematopoietic stem cell transplantation (HSCT) is a medical procedure in the field of hematology and oncology, most often performed for patients with certain cancers of the blood or bone marrow. A lot of patients have no suitable HLA-matched donor within their family, so physicians must activate a "donor search process" by interacting with national and international donor registries who will search their databases for adult unrelated donors or cord blood units (CBU). Information and communication technologies play a key role in the donor search process in donor registries both nationally and internationaly. One of the major challenges for donor registry computer systems is the development of a reliable search algorithm. This work discusses the top-down design of such algorithms and current practice. Based on our experience with systems used by several stem cell donor registries, we highlight typical pitfalls in the implementation of an algorithm and underlying data structure.
Vibration-type particle separation device with piezoceramic vibrator
NASA Astrophysics Data System (ADS)
Ooe, Katsutoshi; Doi, Akihiro
2008-12-01
During hemanalysis, it is necessary to separate blood cells from whole blood. Many blood separation methods, for example, centrifugation and filtering, are in practical use. However, the use of these methods involves problems from the perspectives of processing speed and processing volume. We develop new types of blood separation devices that use piezo-ceramic vibrators. The first device uses a capillary. One end of the capillary is fixed to the device frame, and the other is fixed to a piezo-ceramic vibrator. The vibrator transmits bending waves to the capillary. This device can process only a small amount of solution; therefore, it is not suitable for hemanalysis. In order to solve this problem, we developed a second device; this device has a pair of thin glass plates with a small gap as a substitute for the capillary used in the first device. These devices are based on the fact that particles heavier than water move toward transverse velocity antinodes while those lighter than water move toward velocity nodes. In this report, we demonstrate the highspeed separation of silica microbeads and 50-vol% glycerol water by using these devices. The first device can separate the abovementioned solution within 3 min while the second can separate it within 1 min. Both devices are driven by a rectangular wave of 15 to 20 Vpp. Furthermore, it has been confirmed that red blood cells are separated from diluted whole blood using the first device within approximately 1 min. These devices have transparency, so they can compose as the analysis system with the chemical analyzer easily.
Lee, Ada; Park, Juhee; Lim, Minji; Sunkara, Vijaya; Kim, Shine Young; Kim, Gwang Ha; Kim, Mi-Hyun; Cho, Yoon-Kyoung
2014-11-18
Circulating tumor cells (CTCs) have gained increasing attention owing to their roles in cancer recurrence and progression. Due to the rarity of CTCs in the bloodstream, an enrichment process is essential for effective target cell characterization. However, in a typical pressure-driven microfluidic system, the enrichment process generally requires complicated equipment and long processing times. Furthermore, the commonly used immunoaffinity-based positive selection method is limited, as its recovery rate relies on EpCAM expression of target CTCs, which shows heterogeneity among cell types. Here, we propose a centrifugal-force-based size-selective CTC isolation platform that can isolate and enumerate CTCs from whole blood within 30 s with high purity. The device was validated using the MCF-7 breast cancer cell line spiked in phosphate-buffered saline and whole blood, and an average capture efficiency of 61% was achieved, which is typical for size-based filtration. The capture efficiency for whole blood samples varied from 44% to 84% under various flow conditions and dilution factors. Under the optimized operating conditions, a few hundred white blood cells per 1 mL of whole blood were captured, representing a 20-fold decrease compared to those obtained using a commercialized size-based CTC isolation device. In clinical validation, normalized CTC counts varied from 10 to 60 per 7.5 mL of blood from gastric and lung cancer patients, yielding a detection rate of 50% and 38%, respectively. Overall, our CTC isolation device enables rapid and label-free isolation of CTCs with high purity, which should greatly improve downstream molecular analyses of captured CTCs.
Real-Time Microfluidic Blood-Counting System for PET and SPECT Preclinical Pharmacokinetic Studies.
Convert, Laurence; Lebel, Réjean; Gascon, Suzanne; Fontaine, Réjean; Pratte, Jean-François; Charette, Paul; Aimez, Vincent; Lecomte, Roger
2016-09-01
Small-animal nuclear imaging modalities have become essential tools in the development process of new drugs, diagnostic procedures, and therapies. Quantification of metabolic or physiologic parameters is based on pharmacokinetic modeling of radiotracer biodistribution, which requires the blood input function in addition to tissue images. Such measurements are challenging in small animals because of their small blood volume. In this work, we propose a microfluidic counting system to monitor rodent blood radioactivity in real time, with high efficiency and small detection volume (∼1 μL). A microfluidic channel is built directly above unpackaged p-i-n photodiodes to detect β-particles with maximum efficiency. The device is embedded in a compact system comprising dedicated electronics, shielding, and pumping unit controlled by custom firmware to enable measurements next to small-animal scanners. Data corrections required to use the input function in pharmacokinetic models were established using calibrated solutions of the most common PET and SPECT radiotracers. Sensitivity, dead time, propagation delay, dispersion, background sensitivity, and the effect of sample temperature were characterized. The system was tested for pharmacokinetic studies in mice by quantifying myocardial perfusion and oxygen consumption with (11)C-acetate (PET) and by measuring the arterial input function using (99m)TcO4 (-) (SPECT). Sensitivity for PET isotopes reached 20%-47%, a 2- to 10-fold improvement relative to conventional catheter-based geometries. Furthermore, the system detected (99m)Tc-based SPECT tracers with an efficiency of 4%, an outcome not possible through a catheter. Correction for dead time was found to be unnecessary for small-animal experiments, whereas propagation delay and dispersion within the microfluidic channel were accurately corrected. Background activity and sample temperature were shown to have no influence on measurements. Finally, the system was successfully used in animal studies. A fully operational microfluidic blood-counting system for preclinical pharmacokinetic studies was developed. Microfluidics enabled reliable and high-efficiency measurement of the blood concentration of most common PET and SPECT radiotracers with high temporal resolution in small blood volume. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
Åsprang, Aud Frøysa; Frich, Jan C; Braut, Geir Sverre
2015-10-01
Little is known about the organizational impact of supervisory activities in blood banks. We did a study with the aim to explore health professional's experiences with the external audit of blood transfusion services in Norway. The audit and supervision brought attention to deficiencies in systems and practices, and had been a catalyst for quality improvement. We identify facilitators and barriers to change. While audits can bring attention to known deficiencies, and trigger improvement processes which previously have not been prioritized, involvement of senior management is important to secure change across departments. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Noninvasive blood pressure measurement scheme based on optical fiber sensor
NASA Astrophysics Data System (ADS)
Liu, Xianxuan; Yuan, Xueguang; Zhang, Yangan
2016-10-01
Optical fiber sensing has many advantages, such as volume small, light quality, low loss, strong in anti-jamming. Since the invention of the optical fiber sensing technology in 1977, optical fiber sensing technology has been applied in the military, national defense, aerospace, industrial, medical and other fields in recent years, and made a great contribution to parameter measurement in the environment under the limited condition .With the rapid development of computer, network system, the intelligent optical fiber sensing technology, the sensor technology, the combination of computer and communication technology , the detection, diagnosis and analysis can be automatically and efficiently completed. In this work, we proposed a noninvasive blood pressure detection and analysis scheme which uses optical fiber sensor. Optical fiber sensing system mainly includes the light source, optical fiber, optical detector, optical modulator, the signal processing module and so on. wavelength optical signals were led into the optical fiber sensor and the signals reflected by the human body surface were detected. By comparing actual testing data with the data got by traditional way to measure the blood pressure we can establish models for predicting the blood pressure and achieve noninvasive blood pressure measurement by using spectrum analysis technology. Blood pressure measurement method based on optical fiber sensing system is faster and more convenient than traditional way, and it can get accurate analysis results in a shorter period of time than before, so it can efficiently reduce the time cost and manpower cost.
Noninvasive optoacoustic monitoring of cerebral venous blood oxygenation in newborns
NASA Astrophysics Data System (ADS)
Petrov, Irene Y.; Wynne, Karon E.; Petrov, Yuriy; Esenaliev, Rinat O.; Richardson, C. Joan; Prough, Donald S.
2012-02-01
Cerebral ischemia after birth and during labor is a major cause of death and severe complications such as cerebral palsy. In the USA alone, cerebral palsy results in permanent disability of 10,000 newborns per year and approximately 500,000 of the total population. Currently, no technology is capable of direct monitoring of cerebral oxygenation in newborns. This study proposes the use of an optoacoustic technique for noninvasive cerebral ischemia monitoring by probing the superior sagittal sinus (SSS), a large central cerebral vein. We developed and built a multi-wavelength, near-infrared optoacoustic system suitable for noninvasive monitoring of cerebral ischemia in newborns with normal weight (NBW), low birth-weight (LBW, 1500 - 2499 g) and very low birth-weight (VLBW, < 1500 g). The system was capable of detecting SSS signals through the open anterior and posterior fontanelles as well as through the skull. We tested the system in NBW, LBW, and VLBW newborns (weight range: from 675 g to 3,000 g) admitted to the neonatal intensive care unit. We performed single and continuous measurements of the SSS blood oxygenation. The data acquisition, processing and analysis software developed by our group provided real-time, absolute SSS blood oxygenation measurements. The SSS blood oxygenation ranged from 60% to 80%. Optoacoustic monitoring of the SSS blood oxygenation provides valuable information because adequate cerebral oxygenation would suggest that no therapy was necessary; conversely, evidence of cerebral ischemia would prompt therapy to increase cerebral blood flow.
Kim, Pilkee; Ong, Eng Hui; Yoon, Yong-Jin; Ng, Sum Huan Gary; Puttachat, Khuntontong
2016-01-01
Blood plasma contains biomarkers and substances that indicate the physiological state of an organism, and it can be used to diagnose various diseases or body condition. To improve the accuracy of diagnostic test, it is required to obtain the high purity of blood plasma. This paper presents a low-cost, disposable microfluidics device for blood plasma extraction using magnetophoretic behaviors of blood cells. This device uses alternating magnetophoretic capture modes to trap and separate paramagnetic and diamagnetic cells away from blood plasma. The device system is composed of two parts, a disposable microfluidics chip and a non-disposable (reusable) magnetic field source. Such modularized device helps the structure of the disposable part dramatically simplified, which is beneficial for low-cost mass production. A series of numerical simulation and parametric study have been performed to describe the mechanism of blood cell separation in the microchannel, and the results are discussed. Furthermore, experimental feasibility test has been carried out in order to demonstrate the blood plasma extraction process of the proposed device. In this experiment, pure blood plasma has been successfully extracted with yield of 21.933% from 75 μl 1:10 dilution of deoxygenated blood. PMID:27042252
Redefining and expanding quality assurance.
Robins, J L
1992-12-01
To meet the current standards of excellence necessary for blood establishments, we have learned from industry that a movement toward organization-wide quality assurance/total quality management must be made. Everyone in the organization must accept responsibility for participating in providing the highest quality products and services. Quality must be built into processes and design systems to support these quality processes. Quality assurance has been redefined to include a quality planning function described as the most effective way of designing quality into processes. A formalized quality planning process must be part of quality assurance. Continuous quality improvement has been identified as the strategy every blood establishment must support while striving for error-free processing as the long-term objective. The auditing process has been realigned to support and facilitate this same objective. Implementing organization-wide quality assurance/total quality management is one proven plan for guaranteeing the quality of the 20 million products that are transfused into 4 million patients each year and for moving toward the new order.
Johnson, L; Kwok, M; Marks, D C
2015-02-01
The ErySep system represents an alternative to centrifuge-based whole blood (WB) separation, using gravity and filtration through hollow-fibres (0·2 µm pore size) to produce red blood cell (RBC) and plasma components. The aim of this study was to characterise the quality of ErySep RBC and plasma units compared with standard products from WB held overnight. Two ABO-compatible WB units (n = 24) were pooled and split to produce matched products. One of the WB units was separated into components using the ErySep system (ErySep; n = 12), whereas the other units were separated by centrifugation (control; n = 12). RBC units were stored at 2-6 °C and assessed for in vitro quality over 42 days of storage. Plasma was frozen at -30 °C and tested upon thawing. Processing WB with the ErySep system took longer than controls. The ErySep RBC units were of an appropriate volume (307 ± 17 mL) and contained sufficient Hb (50 ± 2 g unit(-1) ). ErySep RBC components contained more microparticles relative to controls at expiry. The plasma volume, total protein, coagulation factor activity (fibrinogen, FV, FVIII) and number of microparticles was lower in the ErySep units compared with controls. Following overnight hold of WB, the ErySep system was capable of producing RBC components that met specifications. However, the ErySep plasma components did not meet quality specifications. © 2015 British Blood Transfusion Society.
21 CFR 862.1120 - Blood gases (PCO2, PO2) and blood pH test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood gases (PCO2, PO2) and blood pH test system... Test Systems § 862.1120 Blood gases (PCO2, PO2) and blood pH test system. (a) Identification. A blood gases (PCO2, PO2) and blood pH test system is a device intended to measure certain gases in blood, serum...
Blood microcirculation of ischemic pancreatitis
NASA Astrophysics Data System (ADS)
Dmitrieva, Irina V.; Arakelian, Sergei M.; Antonov, Olga V.
1998-06-01
Blood Microcirculation includes many of different components, which are joined by unique multiple system. Capillaries are one of the main link in this morpho-functional chain. Changes in any components of blood microcirculation are revealed by many of pathological processes in different organs and systems of the whole organism. We investigated 250 patients from 30 to 77 ages. Men included 149, women -- 101. The main diagnosis of all patients was the ischaemic pancreatitis. For verification of this diagnosis we used the whole spectrum of clinical, laboratorial and instrumental methods. These were the following: the definition of amylase of blood and urine, sonography and computer's tomography of pancreas, angiography of vessels of pancreas and Doppler's sonography of abdominal aorta and her branches: arteria mesenterica superior (AMS), truncus coeliacus (TC), arteria hepatica communis (AHC) and arteria lienalis (AL). We investigated the blood microcirculation of the mucous of the inferior lip, using Laser Dopplerography. The equipment for this research was LACC-01 with modified computer's program. The normal levels of blood microcirculation were from 120 to 180 Units. But patients with ischaemic pancreatitis had more lower level than in normal situation. This method are suggested as express diagnostic in the cases of abdominal ischaemic pathology. It can used as singel method or in combined with ultrasound Dopplerography.
Blood and interstitial flow in the hierarchical pore space architecture of bone tissue.
Cowin, Stephen C; Cardoso, Luis
2015-03-18
There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen and reduced nutrition. Within the bone, as within other tissues, substances pass from the blood through the arterial walls into the interstitial fluid. The movement of the interstitial fluid carries these substances to the cells within the bone and, at the same time, carries off the waste materials from the cells. Bone tissue would not live without these fluid movements. The development of a model for poroelastic materials with hierarchical pore space architecture for the description of blood flow and interstitial fluid flow in living bone tissue is reviewed. The model is applied to the problem of determining the exchange of pore fluid between the vascular porosity and the lacunar-canalicular porosity in bone tissue due to cyclic mechanical loading and blood pressure. These results are basic to the understanding of interstitial flow in bone tissue that, in turn, is basic to understanding of nutrient transport from the vasculature to the bone cells buried in the bone tissue and to the process of mechanotransduction by these cells. Copyright © 2014 Elsevier Ltd. All rights reserved.
Blood and Interstitial flow in the hierarchical pore space architecture of bone tissue
Cowin, Stephen C.; Cardoso, Luis
2015-01-01
There are two main types of fluid in bone tissue, blood and interstitial fluid. The chemical composition of these fluids varies with time and location in bone. Blood arrives through the arterial system containing oxygen and other nutrients and the blood components depart via the venous system containing less oxygen and reduced nutrition. Within the bone, as within other tissues, substances pass from the blood through the arterial walls into the interstitial fluid. The movement of the interstitial fluid carries these substances to the cells within the bone and, at the same time, carries off the waste materials from the cells. Bone tissue would not live without these fluid movements. The development of a model for poroelastic materials with hierarchical pore space architecture for the description of blood flow and interstitial fluid flow in living bone tissue is reviewed. The model is applied to the problem of determining the exchange of pore fluid between the vascular porosity and the lacunar-canalicular porosity in bone tissue due to cyclic mechanical loading and blood pressure. These results are basic to the understanding of interstitial flow in bone tissue that, in turn, is basic to understanding of nutrient transport from the vasculature to the bone cells buried in the bone tissue and to the process of mechanotransduction by these cells. PMID:25666410
Sime, Stacy L
2005-10-01
As the cost of health care increases, the focus on cost containment grows. The pressure to reduce costs comes at the same time the public focus is on ensuring a zero-risk blood supply. The blood supply has never been safer or more expensive. With the relative vanquishing of transfusion-transmitted diseases, noninfectious risks now exceed infectious risks. This has resulted in a call to refocus blood safety efforts on interconnected processes that link a unit of blood from its volunteer blood donor to the patient. Additional costs in the blood supply chain will create new pressures on an already taxed system that gets little additional reimbursement with each new safety initiative. Opposing interests have created a tenuous relationship between the blood supplier and the transfusion provider. This adversarial relationship does not benefit the ultimate stakeholder, the patient. It is time to create a service partnership that is built on access, cost, and quality. Initiatives must be undertaken at a local, regional, and national level. Locally, blood suppliers and transfusion providers must reevaluate policies that are focused on individual gain and reinvent policies that will reward improvements in the overall system and expand cooperative services. Regionally, both blood suppliers and transfusion providers need to consolidate services to gain cost and quality benefits without compromising the competitive nature of the industry. Nationally, the creation of a strategic plan will help ensure that a mutually beneficial relationship focused on the patient is created between the blood supplier and transfusion provider at all levels. Development of such a plan would benefit the transfusing and supplying parties by identifying areas of common interest and how each may facilitate the achievement of shared benefits.
A hybrid-system model of the coagulation cascade: simulation, sensitivity, and validation.
Makin, Joseph G; Narayanan, Srini
2013-10-01
The process of human blood clotting involves a complex interaction of continuous-time/continuous-state processes and discrete-event/discrete-state phenomena, where the former comprise the various chemical rate equations and the latter comprise both threshold-limited behaviors and binary states (presence/absence of a chemical). Whereas previous blood-clotting models used only continuous dynamics and perforce addressed only portions of the coagulation cascade, we capture both continuous and discrete aspects by modeling it as a hybrid dynamical system. The model was implemented as a hybrid Petri net, a graphical modeling language that extends ordinary Petri nets to cover continuous quantities and continuous-time flows. The primary focus is simulation: (1) fidelity to the clinical data in terms of clotting-factor concentrations and elapsed time; (2) reproduction of known clotting pathologies; and (3) fine-grained predictions which may be used to refine clinical understanding of blood clotting. Next we examine sensitivity to rate-constant perturbation. Finally, we propose a method for titrating between reliance on the model and on prior clinical knowledge. For simplicity, we confine these last two analyses to a critical purely-continuous subsystem of the model.
Toward a computational model of hemostasis
NASA Astrophysics Data System (ADS)
Leiderman, Karin; Danes, Nicholas; Schoeman, Rogier; Neeves, Keith
2017-11-01
Hemostasis is the process by which a blood clot forms to prevent bleeding at a site of injury. The formation time, size and structure of a clot depends on the local hemodynamics and the nature of the injury. Our group has previously developed computational models to study intravascular clot formation, a process confined to the interior of a single vessel. Here we present the first stage of an experimentally-validated, computational model of extravascular clot formation (hemostasis) in which blood through a single vessel initially escapes through a hole in the vessel wall and out a separate injury channel. This stage of the model consists of a system of partial differential equations that describe platelet aggregation and hemodynamics, solved via the finite element method. We also present results from the analogous, in vitro, microfluidic model. In both models, formation of a blood clot occludes the injury channel and stops flow from escaping while blood in the main vessel retains its fluidity. We discuss the different biochemical and hemodynamic effects on clot formation using distinct geometries representing intra- and extravascular injuries.
Platelet-rich plasma differs according to preparation method and human variability.
Mazzocca, Augustus D; McCarthy, Mary Beth R; Chowaniec, David M; Cote, Mark P; Romeo, Anthony A; Bradley, James P; Arciero, Robert A; Beitzel, Knut
2012-02-15
Varying concentrations of blood components in platelet-rich plasma preparations may contribute to the variable results seen in recently published clinical studies. The purposes of this investigation were (1) to quantify the level of platelets, growth factors, red blood cells, and white blood cells in so-called one-step (clinically used commercial devices) and two-step separation systems and (2) to determine the influence of three separate blood draws on the resulting components of platelet-rich plasma. Three different platelet-rich plasma (PRP) separation methods (on blood samples from eight subjects with a mean age [and standard deviation] of 31.6 ± 10.9 years) were used: two single-spin processes (PRPLP and PRPHP) and a double-spin process (PRPDS) were evaluated for concentrations of platelets, red and white blood cells, and growth factors. Additionally, the effect of three repetitive blood draws on platelet-rich plasma components was evaluated. The content and concentrations of platelets, white blood cells, and growth factors for each method of separation differed significantly. All separation techniques resulted in a significant increase in platelet concentration compared with native blood. Platelet and white blood-cell concentrations of the PRPHP procedure were significantly higher than platelet and white blood-cell concentrations produced by the so-called single-step PRPLP and the so-called two-step PRPDS procedures, although significant differences between PRPLP and PRPDS were not observed. Comparing the results of the three blood draws with regard to the reliability of platelet number and cell counts, wide variations of intra-individual numbers were observed. Single-step procedures are capable of producing sufficient amounts of platelets for clinical usage. Within the evaluated procedures, platelet numbers and numbers of white blood cells differ significantly. The intra-individual results of platelet-rich plasma separations showed wide variations in platelet and cell numbers as well as levels of growth factors regardless of separation method.
Biomarker Discovery in Gulf War Veterans: Development of a War Illness Diagnostic Panel
2016-12-01
with GWI reflect a persistent disruption in central nervous system (CNS) proinflammatory and neuroendocrine parameters. These processes can...differences in these systems are more subtle than the frank “abnormalities” identified with standard diagnostic tests (e.g., measures indicating...the coagulation system in Gulf War Illness: a potential pathophysiologic link with chronic fatigue syndrome. A laboratory approach to diagnosis. Blood
Shimazu, Chisato; Hoshino, Satoshi; Furukawa, Taiji
2013-08-01
We constructed an integrated personal identification workflow chart using both bar code reading and an all in-one laboratory information system. The information system not only handles test data but also the information needed for patient guidance in the laboratory department. The reception terminals at the entrance, displays for patient guidance and patient identification tools at blood-sampling booths are all controlled by the information system. The number of patient identification errors was greatly reduced by the system. However, identification errors have not been abolished in the ultrasound department. After re-evaluation of the patient identification process in this department, we recognized that the major reason for the errors came from excessive identification workflow. Ordinarily, an ultrasound test requires patient identification 3 times, because 3 different systems are required during the entire test process, i.e. ultrasound modality system, laboratory information system and a system for producing reports. We are trying to connect the 3 different systems to develop a one-time identification workflow, but it is not a simple task and has not been completed yet. Utilization of the laboratory information system is effective, but is not yet perfect for patient identification. The most fundamental procedure for patient identification is to ask a person's name even today. Everyday checks in the ordinary workflow and everyone's participation in safety-management activity are important for the prevention of patient identification errors.
Elliott, Paul; Peakman, Tim C
2008-04-01
UK Biobank is a large prospective study in the UK to investigate the role of genetic factors, environmental exposures and lifestyle in the causes of major diseases of late and middle age. Extensive data and biological samples are being collected from 500,000 participants aged between 40 and 69 years. The biological samples that are collected and how they are processed and stored will have a major impact on the future scientific usefulness of the UK Biobank resource. The aim of the UK Biobank sample handling and storage protocol is to specify methods for the collection and storage of participant samples that give maximum scientific return within the available budget. Processing or storage methods that, as far as can be predicted, will preclude current or future assays have been avoided. The protocol was developed through a review of the literature on sample handling and processing, wide consultation within the academic community and peer review. Protocol development addressed which samples should be collected, how and when they should be processed and how the processed samples should be stored to ensure their long-term integrity. The recommended protocol was extensively tested in a series of validation studies. UK Biobank collects about 45 ml blood and 9 ml of urine with minimal local processing from each participant using the vacutainer system. A variety of preservatives, anti-coagulants and clot accelerators is used appropriate to the expected end use of the samples. Collection of other material (hair, nails, saliva and faeces) was also considered but rejected for the full cohort. Blood and urine samples from participants are transported overnight by commercial courier to a central laboratory where they are processed and aliquots of urine, plasma, serum, white cells and red cells stored in ultra-low temperature archives. Aliquots of whole blood are also stored for potential future production of immortalized cell lines. A standard panel of haematology assays is completed on whole blood from all participants, since such assays need to be conducted on fresh samples (whereas other assays can be done on stored samples). By the end of the recruitment phase, 15 million sample aliquots will be stored in two geographically separate archives: 9.5 million in a -80 degrees C automated archive and 5.5 million in a manual liquid nitrogen archive at -180 degrees C. Because of the size of the study and the numbers of samples obtained from participants, the protocol stipulates a highly automated approach for the processing and storage of samples. Implementation of the processes, technology, systems and facilities has followed best practices used in manufacturing industry to reduce project risk and to build in quality and robustness. The data produced from sample collection, processing and storage are highly complex and are managed by a commercially available LIMS system fully integrated with the entire process. The sample handling and storage protocol adopted by UK Biobank provides quality assured and validated methods that are feasible within the available funding and reflect the size and aims of the project. Experience from recruiting and processing the first 40,000 participants to the study demonstrates that the adopted methods and technologies are fit-for-purpose and robust.
Antfolk, Maria; Magnusson, Cecilia; Augustsson, Per; Lilja, Hans; Laurell, Thomas
2015-09-15
Enrichment of rare cells from peripheral blood has emerged as a means to enable noninvasive diagnostics and development of personalized drugs, commonly associated with a prerequisite to concentrate the enriched rare cell population prior to molecular analysis or culture. However, common concentration by centrifugation has important limitations when processing low cell numbers. Here, we report on an integrated acoustophoresis-based rare cell enrichment system combined with integrated concentration. Polystyrene 7 μm microparticles could be separated from 5 μm particles with a recovery of 99.3 ± 0.3% at a contamination of 0.1 ± 0.03%, with an overall 25.7 ± 1.7-fold concentration of the recovered 7 μm particles. At a flow rate of 100 μL/min, breast cancer cells (MCF7) spiked into red blood cell-lysed human blood were separated with an efficiency of 91.8 ± 1.0% with a contamination of 0.6 ± 0.1% from white blood cells with a 23.8 ± 1.3-fold concentration of cancer cells. The recovery of prostate cancer cells (DU145) spiked into whole blood was 84.1 ± 2.1% with 0.2 ± 0.04% contamination of white blood cells with a 9.6 ± 0.4-fold concentration of cancer cells. This simultaneous on-chip separation and concentration shows feasibility of future acoustofluidic systems for rapid label-free enrichment and molecular characterization of circulating tumor cells using peripheral venous blood in clinical practice.
A Stochastic Simulator of a Blood Product Donation Environment with Demand Spikes and Supply Shocks
An, Ming-Wen; Reich, Nicholas G.; Crawford, Stephen O.; Brookmeyer, Ron; Louis, Thomas A.; Nelson, Kenrad E.
2011-01-01
The availability of an adequate blood supply is a critical public health need. An influenza epidemic or another crisis affecting population mobility could create a critical donor shortage, which could profoundly impact blood availability. We developed a simulation model for the blood supply environment in the United States to assess the likely impact on blood availability of factors such as an epidemic. We developed a simulator of a multi-state model with transitions among states. Weekly numbers of blood units donated and needed were generated by negative binomial stochastic processes. The simulator allows exploration of the blood system under certain conditions of supply and demand rates, and can be used for planning purposes to prepare for sudden changes in the public's health. The simulator incorporates three donor groups (first-time, sporadic, and regular), immigration and emigration, deferral period, and adjustment factors for recruitment. We illustrate possible uses of the simulator by specifying input values for an -week flu epidemic, resulting in a moderate supply shock and demand spike (for example, from postponed elective surgeries), and different recruitment strategies. The input values are based in part on data from a regional blood center of the American Red Cross during –. Our results from these scenarios suggest that the key to alleviating deficit effects of a system shock may be appropriate timing and duration of recruitment efforts, in turn depending critically on anticipating shocks and rapidly implementing recruitment efforts. PMID:21814550
A stochastic simulator of a blood product donation environment with demand spikes and supply shocks.
An, Ming-Wen; Reich, Nicholas G; Crawford, Stephen O; Brookmeyer, Ron; Louis, Thomas A; Nelson, Kenrad E
2011-01-01
The availability of an adequate blood supply is a critical public health need. An influenza epidemic or another crisis affecting population mobility could create a critical donor shortage, which could profoundly impact blood availability. We developed a simulation model for the blood supply environment in the United States to assess the likely impact on blood availability of factors such as an epidemic. We developed a simulator of a multi-state model with transitions among states. Weekly numbers of blood units donated and needed were generated by negative binomial stochastic processes. The simulator allows exploration of the blood system under certain conditions of supply and demand rates, and can be used for planning purposes to prepare for sudden changes in the public's health. The simulator incorporates three donor groups (first-time, sporadic, and regular), immigration and emigration, deferral period, and adjustment factors for recruitment. We illustrate possible uses of the simulator by specifying input values for an 8-week flu epidemic, resulting in a moderate supply shock and demand spike (for example, from postponed elective surgeries), and different recruitment strategies. The input values are based in part on data from a regional blood center of the American Red Cross during 1996-2005. Our results from these scenarios suggest that the key to alleviating deficit effects of a system shock may be appropriate timing and duration of recruitment efforts, in turn depending critically on anticipating shocks and rapidly implementing recruitment efforts.
Zhu, Li-Wei; Yang, Xue-Mei; Xu, Xiao-Qin; Xu, Jian; Lu, Huang-Jun; Yan, Li-Xing
2008-10-01
This study was aimed to analyze the results of false positive reaction in bacterial detection of blood samples with BacT/ALERT 3D system, to evaluate the specificity of this system, and to decrease the false positive reaction. Each reaction flasks in past five years were processed for bacteria isolation and identification. When the initial cultures were positive, the remaining samples and the corresponding units were recultured if still available. 11395 blood samples were detected. It is worthy of note that the incubator temperature should be stabilized, avoiding fluctuation; when the cultures were alarmed, the reaction flasks showed be kept some hours for further incubation so as to trace a sharply increasing signal to support the judgement of true bacterial growth. The results indicated that 122 samples (1.07%) wee positive at initial culture, out of them 107 samples (88.7%) were found bacterial, and 15 samples (12.3%) were found nothing. The detection curves of positive samples resulted from bacterial growth showed ascent. In conclusion, maintenance of temperature stability and avoidance of temperature fluctuation in incubator could decrease the occurrence of false-positive reaction in detection process. The reaction flasks with positive results at initial culture should be recultured, and whether existence of a sharply ascending logarilhimic growth phase in bacterial growth curve should be further detected, which are helpful to distinguish false-positive reactions from true positive, and thus increase the specificity of the BacT/ALERT system.
Development of the blood-brain barrier: a historical point of view.
Ribatti, Domenico; Nico, Beatrice; Crivellato, Enrico; Artico, Marco
2006-01-01
Although there has been considerable controversy since the observation by Ehrlich more than 100 years ago that the brain did not take up dyes from the vascular system, the concept of an endothelial blood-brain barrier (BBB) was confirmed by the unequivocal demonstration that the passage of molecules from blood to brain and vice versa was prevented by endothelial tight junctions (TJs). There are three major functions implicated in the term "BBB": protection of the brain from the blood milieu, selective transport, and metabolism or modification of blood- or brain-borne substances. The BBB phenotype develops under the influence of associated brain cells, especially astrocytic glia, and consists of complex TJs and a number of specific transport and enzyme systems that regulate molecular traffic across the endothelial cells. The development of the BBB is a complex process that leads to endothelial cells with unique permeability characteristics due to high electrical resistance and the expression of specific transporters and metabolic pathways. This review article summarizes the historical background underlying our current knowledge of the cellular and molecular mechanisms involved in the development and maintenance of the BBB. (c) 2006 Wiley-Liss, Inc.
Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals.
Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X; Song, Houbing; Ming, Zhong
2018-01-01
With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.
Design of a Continuous Blood Pressure Measurement System Based on Pulse Wave and ECG Signals
Li, Jian-Qiang; Li, Rui; Chen, Zhuang-Zhuang; Deng, Gen-Qiang; Wang, Huihui; Mavromoustakis, Constandinos X.; Ming, Zhong
2018-01-01
With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system. PMID:29541556
Spreading of blood drops over dry porous substrate: complete wetting case.
Chao, Tzu Chieh; Arjmandi-Tash, Omid; Das, Diganta B; Starov, Victor M
2015-05-15
The process of dried blood spot sampling involves simultaneous spreading and penetration of blood into a porous filter paper with subsequent evaporation and drying. Spreading of small drops of blood, which is a non-Newtonian liquid, over a dry porous layer is investigated from both theoretical and experimental points of view. A system of two differential equations is derived, which describes the time evolution of radii of both the drop base and the wetted region inside the porous medium. The system of equations does not include any fitting parameters. The predicted time evolutions of both radii are compared with experimental data published earlier. For a given power law dependency of viscosity of blood with different hematocrit level, radii of both drop base and wetted region, and contact angle fell on three universal curves if appropriate scales are used with a plot of the dimensionless radii of the drop base and the wetted region inside the porous layer and dynamic contact angle on dimensionless time. The predicted theoretical relationships are three universal curves accounting satisfactorily for the experimental data. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.
Low GI Food with Barley in Space Foods
NASA Astrophysics Data System (ADS)
Katayama, Naomi; Sugimoto, Manabu; Hashimoto, Hirofumi; Kihara, Makoto; Yamashita, Masamichi; Space Agriculture Task Force
The construction of the life-support system to perform space, moon base, Mars emigration is demanded. The space foods will play a very important role of life support on this occasion. Particularly, in environment of the microgravity, our metabolism becomes less than the face of the Earth. The management of the blood sugar level is very important. We need to eat the meal which will be rise in blood sugar level slowly. The barley which includes much water-soluble dietary fibers is helpful to make low GI space food. After eating 30% barley with unpolished rice, blood sugar level was rise slowly. The cooking process is very important to our body in thinking about digestion and absorption. Soft foods, long-heated foods and grind-foods are easy to digest. After eating these-foods, our blood sugar level will rise, easily. We introduce the space foods with 30% wheat that the blood sugar level is hard to rising.
Multiscale Simulation of Blood Flow in Brain Arteries with an Aneurysm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Leopold Grinberg; Vitali Morozov; Dmitry A. Fedosov
2013-04-24
Multi-scale modeling of arterial blood flow can shed light on the interaction between events happening at micro- and meso-scales (i.e., adhesion of red blood cells to the arterial wall, clot formation) and at macro-scales (i.e., change in flow patterns due to the clot). Coupled numerical simulations of such multi-scale flow require state-of-the-art computers and algorithms, along with techniques for multi-scale visualizations.This animation presents results of studies used in the development of a multi-scale visualization methodology. First we use streamlines to show the path the flow is taking as it moves through the system, including the aneurysm. Next we investigate themore » process of thrombus (blood clot) formation, which may be responsible for the rupture of aneurysms, by concentrating on the platelet blood cells, observing as they aggregate on the wall of the aneurysm.« less
Liu, Yang; Luo, Zhi-Qiang; Lv, Bei-Ran; Zhao, Hai-Yu; Dong, Ling
2016-04-01
The multiple components in Chinese herbal medicines (CHMS) will experience complex absorption and metabolism before entering the blood system. Previous studies often lay emphasis on the components in blood. However, the dynamic and sequential absorption and metabolism process following multi-component oral administration has not been studied. In this study, the in situ closed-loop method combined with LC-MS techniques were employed to study the sequential process of Chuanxiong Rhizoma decoction (RCD). A total of 14 major components were identified in RCD. Among them, ferulic acid, senkyunolide J, senkyunolide I, senkyunolide F, senkyunolide G, and butylidenephthalide were detected in all of the samples, indicating that the six components could be absorbed into blood in prototype. Butylphthalide, E-ligustilide, Z-ligustilide, cnidilide, senkyunolide A and senkyunolide Q were not detected in all the samples, suggesting that the six components may not be absorbed or metabolized before entering the hepatic portal vein. Senkyunolide H could be metabolized by the liver, while senkyunolide M could be metabolized by both liver and intestinal flora. This study clearly demonstrated the changes in the absorption and metabolism process following multi-component oral administration of RCD, so as to convert the static multi-component absorption process into a comprehensive dynamic and continuous absorption and metabolism process. Copyright© by the Chinese Pharmaceutical Association.
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.54 Processing. (a) Processing the plasma. (1) The plasma shall be separated from the red blood cells by centrifugation to obtain essentially cell-free plasma. (2) The plasma shall be placed in a freezer within 8 hours after blood collection or...
Fresenius AS.TEC204 blood cell separator.
Sugai, Mikiya
2003-02-01
Fresenius AS.TEC204 is a third-generation blood cell separator that incorporates the continuous centrifugal separation method and automatic control of the cell separation process. Continuous centrifugation separates cell components according to their specific gravity, and different cell components are either harvested or eliminated as needed. The interface between the red blood cell and plasma is optically detected, and the Interface Control (IFC) cooperates with different pumps, monitors and detectors to harvest required components automatically. The system is composed of three major sections; the Front Panel Unit; the Pump Unit, and the Centrifuge Unit. This unit can be used for a wide variety of clinical applications including collection of platelets, peripheral blood stem cells, bone marrow stem cells, granulocytes, mononuclear cells, and exchange of plasma or red cells, and for plasma treatment.
Leucocyte classification for leukaemia detection using image processing techniques.
Putzu, Lorenzo; Caocci, Giovanni; Di Ruberto, Cecilia
2014-11-01
The counting and classification of blood cells allow for the evaluation and diagnosis of a vast number of diseases. The analysis of white blood cells (WBCs) allows for the detection of acute lymphoblastic leukaemia (ALL), a blood cancer that can be fatal if left untreated. Currently, the morphological analysis of blood cells is performed manually by skilled operators. However, this method has numerous drawbacks, such as slow analysis, non-standard accuracy, and dependences on the operator's skill. Few examples of automated systems that can analyse and classify blood cells have been reported in the literature, and most of these systems are only partially developed. This paper presents a complete and fully automated method for WBC identification and classification using microscopic images. In contrast to other approaches that identify the nuclei first, which are more prominent than other components, the proposed approach isolates the whole leucocyte and then separates the nucleus and cytoplasm. This approach is necessary to analyse each cell component in detail. From each cell component, different features, such as shape, colour and texture, are extracted using a new approach for background pixel removal. This feature set was used to train different classification models in order to determine which one is most suitable for the detection of leukaemia. Using our method, 245 of 267 total leucocytes were properly identified (92% accuracy) from 33 images taken with the same camera and under the same lighting conditions. Performing this evaluation using different classification models allowed us to establish that the support vector machine with a Gaussian radial basis kernel is the most suitable model for the identification of ALL, with an accuracy of 93% and a sensitivity of 98%. Furthermore, we evaluated the goodness of our new feature set, which displayed better performance with each evaluated classification model. The proposed method permits the analysis of blood cells automatically via image processing techniques, and it represents a medical tool to avoid the numerous drawbacks associated with manual observation. This process could also be used for counting, as it provides excellent performance and allows for early diagnostic suspicion, which can then be confirmed by a haematologist through specialised techniques. Copyright © 2014 Elsevier B.V. All rights reserved.
Printed microfluidic filter for heparinized blood.
Bilatto, Stanley E R; Adly, Nouran Y; Correa, Daniel S; Wolfrum, Bernhard; Offenhäusser, Andreas; Yakushenko, Alexey
2017-05-01
A simple lab-on-a-chip method for blood plasma separation was developed by combining stereolithographic 3D printing with inkjet printing, creating a completely sealed microfluidic device. In some approaches, one dilutes the blood sample before separation, reducing the concentration of a target analyte and increasing a contamination risk. In this work, a single drop (8 μ l) of heparinized whole blood could be efficiently filtered using a capillary effect without any external driving forces and without dilution. The blood storage in heparin tubes during 24 h at 4 °C initiated the formation of small crystals that formed auto-filtration structures in the sample upon entering the 3D-printed device, with pores smaller than the red blood cells, separating plasma from the cellular content. The total filtration process took less than 10 s. The presented printed plasma filtration microfluidics fabricated with a rapid prototyping approach is a miniaturized, fast and easy-to-operate device that can be integrated into healthcare/portable systems for point-of-care diagnostics.
2011-01-01
Background Diagnosis of blood borne infectious diseases relies primarily on the detection of the causative agent in the blood sample. Molecular techniques offer sensitive and specific tools for this although considerable difficulties exist when using these approaches in the field environment. In large scale epidemiological studies, FTA®cards are becoming increasingly popular for the rapid collection and archiving of a large number of samples. However, there are some difficulties in the downstream processing of these cards which is essential for the accurate diagnosis of infection. Here we describe recommendations for the best practice approach for sample processing from FTA®cards for the molecular diagnosis of trypanosomiasis using PCR. Results A comparison of five techniques was made. Detection from directly applied whole blood was less sensitive (35.6%) than whole blood which was subsequently eluted from the cards using Chelex®100 (56.4%). Better apparent sensitivity was achieved when blood was lysed prior to application on the FTA cards (73.3%) although this was not significant. This did not improve with subsequent elution using Chelex®100 (73.3%) and was not significantly different from direct DNA extraction from blood in the field (68.3%). Conclusions Based on these results, the degree of effort required for each of these techniques and the difficulty of DNA extraction under field conditions, we recommend that blood is transferred onto FTA cards whole followed by elution in Chelex®100 as the best approach. PMID:21548975
NASA Astrophysics Data System (ADS)
Desjardins, Candida L.; Antonelli, Lynn T.; Soares, Edward
2007-02-01
The use of lasers to remotely and non-invasively detect the blood pressure waveform of humans and animals would provide a powerful diagnostic tool. Current blood pressure measurement tools, such as a cuff, are not useful for burn and trauma victims, and animals require catheterization to acquire accurate blood pressure information. The purpose of our sensor method and apparatus invention is to remotely and non-invasively detect the blood pulse waveform of both animals and humans. This device is used to monitor an animal or human's skin in proximity to an artery using radiation from a laser Doppler vibrometer (LDV). This system measures the velocity (or displacement) of the pulsatile motion of the skin, indicative of physiological parameters of the arterial motion in relation to the cardiac cycle. Tests have been conducted that measures surface velocity with an LDV and a signal-processing unit, with enhanced detection obtained with optional hardware including a retro-reflector dot. The blood pulse waveform is obtained by integrating the velocity signal to get surface displacement using standard signal processing techniques. Continuous recording of the blood pulse waveform yields data containing information on cardiac health and can be analyzed to identify important events in the cardiac cycle, such as heart rate, the timing of peak systole, left ventricular ejection time and aortic valve closure. Experimental results are provided that demonstrates the current capabilities of the optical, non-contact sensor for the continuous, non-contact recording of the blood pulse waveform without causing patient distress.
White blood cell counting analysis of blood smear images using various segmentation strategies
NASA Astrophysics Data System (ADS)
Safuan, Syadia Nabilah Mohd; Tomari, Razali; Zakaria, Wan Nurshazwani Wan; Othman, Nurmiza
2017-09-01
In white blood cell (WBC) diagnosis, the most crucial measurement parameter is the WBC counting. Such information is widely used to evaluate the effectiveness of cancer therapy and to diagnose several hidden infection within human body. The current practice of manual WBC counting is laborious and a very subjective assessment which leads to the invention of computer aided system (CAS) with rigorous image processing solution. In the CAS counting work, segmentation is the crucial step to ensure the accuracy of the counted cell. The optimal segmentation strategy that can work under various blood smeared image acquisition conditions is remain a great challenge. In this paper, a comparison between different segmentation methods based on color space analysis to get the best counting outcome is elaborated. Initially, color space correction is applied to the original blood smeared image to standardize the image color intensity level. Next, white blood cell segmentation is performed by using combination of several color analysis subtraction which are RGB, CMYK and HSV, and Otsu thresholding. Noises and unwanted regions that present after the segmentation process is eliminated by applying a combination of morphological and Connected Component Labelling (CCL) filter. Eventually, Circle Hough Transform (CHT) method is applied to the segmented image to estimate the number of WBC including the one under the clump region. From the experiment, it is found that G-S yields the best performance.
Geng, Jinhai; Liu, Gangjun; Chen, Zhongping
2013-01-01
Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d1/e) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening. PMID:23392340
Xu, Xiangqun; Geng, Jinhai; Liu, Gangjun; Chen, Zhongping
2013-08-01
Optical properties of human blood during coagulation were studied using optical coherence tomography (OCT) and the parameter of clotting time derived from the 1/e light penetration depth (d(1/e)) versus time was developed in our previous work. In this study, in order to know if a new OCT test can characterize the blood-coagulation process under different treatments in vitro, the effects of two different activators (calcium ions and thrombin) and anticoagulants, i.e., acetylsalicylic acid (ASA, a well-known drug aspirin) and melagatran (a direct thrombin inhibitor), at various concentrations are evaluated. A swept-source OCT system with a 1300 nm center wavelength is used for detecting the blood-coagulation process in vitro under a static condition. A dynamic study of d1/e reveals a typical behavior due to coagulation induced by both calcium ions and thrombin, and the clotting time is concentration-dependent. Dose-dependent ASA and melagatran prolong the clotting times. ASA and melagatran have different effects on blood coagulation. As expected, melagatran is much more effective than ASA in anticoagulation by the OCT measurements. The OCT assay appears to be a simple method for the measurement of blood coagulation to assess the effects of activators and anticoagulants, which can be used for activator and anticoagulant screening.
NASA Astrophysics Data System (ADS)
Nawani, Jigna; Rixius, Julia; Neuhaus, Birgit J.
2016-08-01
Empirical analysis of secondary biology classrooms revealed that, on average, 68% of teaching time in Germany revolved around processing tasks. Quality of instruction can thus be assessed by analyzing the quality of tasks used in classroom discourse. This quasi-experimental study analyzed how teachers used tasks in 38 videotaped biology lessons pertaining to the topic 'blood and circulatory system'. Two fundamental characteristics used to analyze tasks include: (1) required cognitive level of processing (e.g. low level information processing: repetiition, summary, define, classify and high level information processing: interpret-analyze data, formulate hypothesis, etc.) and (2) complexity of task content (e.g. if tasks require use of factual, linking or concept level content). Additionally, students' cognitive knowledge structure about the topic 'blood and circulatory system' was measured using student-drawn concept maps (N = 970 students). Finally, linear multilevel models were created with high-level cognitive processing tasks and higher content complexity tasks as class-level predictors and students' prior knowledge, students' interest in biology, and students' interest in biology activities as control covariates. Results showed a positive influence of high-level cognitive processing tasks (β = 0.07; p < .01) on students' cognitive knowledge structure. However, there was no observed effect of higher content complexity tasks on students' cognitive knowledge structure. Presented findings encourage the use of high-level cognitive processing tasks in biology instruction.
Che, J; Tian, M; Ding, G; Huai, Q; Dong, P; Li, Y; Li, S
2013-08-01
The aim of this study was to investigate the contribution of the perioperative cell salvage process to the changes in erythrocyte 2,3-disphosphoglycerate (2,3-DPG) and glucose-6-phosphate dehydrogenase (G-6-PD) levels and phosphatidylserine (PS) expression using a self-control study comparing washed blood with venous blood. Thirty patients undergoing elective heart and blood vessel surgery were enrolled. Blood was collected and processed using a Fresenius continuous autotransfusion system device. 2,3-DPG and G-6-PD activities, as well as PS expression, from both venous and washed red blood cells (RBC) were measured. We also compared these indicators among washed RBC at 6 h, washed RBC at 0 h, and venous RBC. 2,3-DPG and G-6-PD activities in washed blood at 0 h were significantly higher than in venous RBC (2,3-DPG, venous vs. washed blood P < 0.05; G-6-PD, venous vs. washed blood P < 0.05). Flow cytometry results showed no differences between venous blood and washed RBC at 0 h (n = 23, P > 0.05). 2,3-DPG activity in washed RBC that were allowed to stand for 6 h decreased compared with that in venous blood (venous vs. washed blood at 6 h P < 0.01), whereas no significant difference was observed in G-6-PD activity (venous. vs. washed blood at 6 h P > 0.05). Compared with venous RBC, washed RBC from intraoperative cell salvage exhibited good oxygen-carrying and antioxidant capacities. However, the oxygen-carrying capacity of washed RBC that were allowed to stand for 6 h was not as good as that of venous RBC. Thus, we suggest that washed RBC that were left to stand for more than 6 h should not be reinfused. © 2012 John Wiley & Sons Ltd.
77 FR 46096 - Statistical Process Controls for Blood Establishments; Public Workshop
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
...] Statistical Process Controls for Blood Establishments; Public Workshop AGENCY: Food and Drug Administration... workshop entitled: ``Statistical Process Controls for Blood Establishments.'' The purpose of this public workshop is to discuss the implementation of statistical process controls to validate and monitor...
Impact of nitinol stent surface processing on in-vivo nickel release and biological response.
Nagaraja, Srinidhi; Sullivan, Stacey J L; Stafford, Philip R; Lucas, Anne D; Malkin, Elon
2018-05-01
Although nitinol is widely used in percutaneous cardiovascular interventions, a causal relationship between nickel released from implanted cardiovascular devices and adverse systemic or local biological responses has not been established. The objective of this study was to investigate the relationship between nitinol surface processing, in-vivo nickel release, and biocompatibility. Nitinol stents manufactured using select surface treatments were implanted into the iliac arteries of minipigs for 6 months. Clinical chemistry profile, complete blood count, serum and urine nickel analyses were performed periodically during the implantation period. After explant, stented arteries were either digested and analyzed for local nickel concentration or fixed and sectioned for histopathological analysis of stenosis and inflammation within the artery. The results indicated that markers for liver and kidney function were not different than baseline values throughout 180 days of implantation regardless of surface finish. In addition, white blood cell, red blood cell, and platelet counts were similar to baseline values for all surface finishes. Systemic nickel concentrations in serum and urine were not significantly different between processing groups and comparable to baseline values during 180 days of implantation. However, stents with non-optimized surface finishing had significantly greater nickel levels in the surrounding artery compared to polished stents. These stents had increased stenosis with potential for local inflammation compared to polished stents. These findings demonstrate that proper polishing of nitinol surfaces can reduce in-vivo nickel release locally, which may aid in minimizing adverse inflammatory reactions and restenosis. Nitinol is a commonly used material in cardiovascular medical devices. However, relationships between nitinol surface finishing, in-vivo metal ion release, and adverse biological responses have yet to be established. We addressed this knowledge gap by implanting single and overlapped nitinol stents with different surface finishes to assess systemic impact on minipigs (i.e. serum and urine nickel levels, liver and kidney function, immune and blood count) over the 6 month implantation period. In addition, nickel levels and histopathology in stented arteries were analyzed on explant to determine relationships between surface processing and local adverse tissue reactions. The findings presented here highlight the importance of surface processing on in-vivo nickel release and subsequent impact on local biological response for nitinol implants. Published by Elsevier Ltd.
NASA Technical Reports Server (NTRS)
1992-01-01
A heat sealing process was developed by SEBRA based on technology that originated in work with NASA's Jet Propulsion Laboratory. The project involved connecting and transferring blood and fluids between sterile plastic containers while maintaining a closed system. SEBRA markets the PIRF Process to manufacturers of medical catheters. It is a precisely controlled method of heating thermoplastic materials in a mold to form or weld catheters and other products. The process offers advantages in fast, precise welding or shape forming of catheters as well as applications in a variety of other industries.
Ohlsson, Pelle; Petersson, Klara; Augustsson, Per; Laurell, Thomas
2018-06-14
Sepsis is a common and often deadly systemic response to an infection, usually caused by bacteria. The gold standard for finding the causing pathogen in a blood sample is blood culture, which may take hours to days. Shortening the time to diagnosis would significantly reduce mortality. To replace the time-consuming blood culture we are developing a method to directly separate bacteria from red and white blood cells to enable faster bacteria identification. The blood cells are moved from the sample flow into a parallel stream using acoustophoresis. Due to their smaller size, the bacteria are not affected by the acoustic field and therefore remain in the blood plasma flow and can be directed to a separate outlet. When optimizing for sample throughput, 1 ml of undiluted whole blood equivalent can be processed within 12.5 min, while maintaining the bacteria recovery at 90% and the blood cell removal above 99%. That makes this the fastest label-free microfluidic continuous flow method per channel to separate bacteria from blood with high bacteria recovery (>80%). The high throughput was achieved by matching the acoustic impedance of the parallel stream to that of the blood sample, to avoid that acoustic forces relocate the fluid streams.
Red blood cell microparticles and blood group antigens: an analysis by flow cytometry
Canellini, Giorgia; Rubin, Olivier; Delobel, Julien; Crettaz, David; Lion, Niels; Tissot, Jean-Daniel
2012-01-01
Background The storage of blood induces the formation of erythrocytes-derived microparticles. Their pathogenic role in blood transfusion is not known so far, especially the risk to trigger alloantibody production in the recipient. This work aims to study the expression of clinically significant blood group antigens on the surface of red blood cells microparticles. Material and methods Red blood cells contained in erythrocyte concentrates were stained with specific antibodies directed against blood group antigens and routinely used in immunohematology practice. After inducing erythrocytes vesiculation with calcium ionophore, the presence of blood group antigens was analysed by flow cytometry. Results The expression of several blood group antigens from the RH, KEL, JK, FY, MNS, LE and LU systems was detected on erythrocyte microparticles. The presence of M (MNS1), N (MNS2) and s (MNS4) antigens could not be demonstrated by flow cytometry, despite that glycophorin A and B were identified on microparticles using anti-CD235a and anti-MNS3. Discussion We conclude that blood group antigens are localized on erythrocytes-derived microparticles and probably keep their immunogenicity because of their capacity to bind specific antibody. Selective segregation process during vesiculation or their ability to elicit an immune response in vivo has to be tested by further studies. PMID:22890266
Sugiyama, Atsushi; Takahara, Akira; Yatomi, Yutaka; Satoh, Yoshioki; Nakamura, Yuji; Hashimoto, Keitaro
2003-06-01
Given the limited information, physiological roles of Rho-kinase in the cardiac conduction system and ventricular repolarization process were assessed in comparison with those in the coronary vascular tone. A specific Rho-kinase inhibitor Y-27632 was administered to the nutrient coronary artery of the canine isolated, blood-perfused atrioventricular node preparation under the monitoring of the ventricular monophasic action potentials. Administration of Y-27632 moderately suppressed the atrioventricular nodal conduction, slightly but significantly accelerated the repolarization process, and potently increased the coronary blood flow, whereas it hardly affected the intraventricular conduction. The estimated concentrations of Y-27632 causing the currently observed effects were enough to inhibit Rho-kinase. These results suggest that constitutional Rho-kinase functions to moderately facilitate the atrioventricular nodal conduction, slightly delay ventricular repolarization process, and significantly increase the coronary vascular tone.
Gapeev, A B; Romanova, N A; Chemeris, N K
2011-01-01
Using the alkaline single cell gel electrophoresis technique (comet assay), changes in chromatin structure of peripheral blood leukocytes and peritoneal neutrophils have been studied in mice exposed to low-intensity extremely high-frequency electromagnetic radiation (42.2 GHz, 0.1 mW/cm2, 20 min at 1 h after induction of inflammation) against the background of the systemic inflammatory process. It was revealed that the exposure of mice with the developing inflammation leads to a pronounced decrease in the level of DNA damage to peripheral blood leukocytes and peritoneal neutrophils. It is supposed that the changes in the chromatin structure of lymphoid cells have a genoprotective character in the inflammatory process and can underlie the mechanisms of realization of antiinflammatory effects of the electromagnetic radiation.
Strategy for the hemocompatibility testing of microparticles.
Braune, S; Basu, S; Kratz, K; Johansson, J Bäckemo; Reinthaler, M; Lendlein, A; Jung, F
2016-01-01
Polymer-based microparticles are applied as non-thrombogenic or thrombogenic materials in a wide variety of intra- or extra-corporeal medical devices. As demanded by the regulatory agencies, the hemocompatibility of these blood contacting biomaterials has to be evaluated in vitro to ensure that the particle systems appropriately fulfill the envisioned function without causing undesired events such as thrombosis or inflammation. Currently described in vitro assays for hemocompatibility testing of particles comprise tests with different single cell types (e.g. erythrocytes or leukocytes), varying concentrations/dilutions of the used blood cells or whole blood, which are not standardized.Here, we report about an in vitro dynamic test system for studying the hemocompatibility of polymeric microparticles utilizing fresh human whole blood from apparently healthy subjects, collected and processed under standardized conditions. Spherical poly(ether imide) microparticles with an average diameter of 140±30 μm were utilized as model systems. Reported as candidate materials for the removal of uremic toxins, these microparticles are anticipated to facilitate optimal flow conditions in a dialyzer with minimal backflow and blood cell damage. Pristine (PEI) and potassium hydroxide (PEI-KOH) functionalized microparticles exhibited similarly nanoporous surfaces (PEI: ØExternal pore = 90±60 nm; PEI-KOH ØExternal pore = 150±130 nm) but varying water wettabilities (PEI: θadv = 112±10° PEI-KOH θadv = 60±2°). The nanoporosity of the microparticle surfaces allows the exchange of toxic solutes from blood towards the interconnective pores in the particle core, while an immigration of the substantially larger blood cells is inhibited.Sterilized PEI microparticles were incorporated -air-free -in a syringe-based test system and exposed to whole blood for 60 minutes under gentle agitation. Thereafter, thrombi formation on the particles surfaces were analyzed microscopically. In the collected whole blood the non-adherent/circulating single blood cells were quantified via a differentiated complete blood cell count and the activation of platelets (P-Selectin expression, secretion and release), platelet function (PFA100 closure time) as well as thrombin formation (thrombin-antithrombin-complex) was analyzed. Free hemoglobin (HGB) levels were quantified as a measure of hemolysis.Microscopic evaluation revealed thrombi formation and particle aggregates for all tested microparticles. Reduction of circulating blood cells differed significantly between the particle types. Particularly, platelet and monocyte counts decreased up to 50% compared to the control (syringe filled with whole blood but without microparticles). In accordance, platelet activation, thrombin levels and degrees of hemolysis were clearly elevated in the particle loaded test systems and allowed a differentiation between the particle types. Increased PFA100 closure times (as activating agent a combination of collagen/ADP was used) indicated a similarly reduced ability of platelets to adhere and form stable aggregates independent from the particle type tested. This observation is most probably a consequence of the strong thrombus formation in the test system, which is associated with a reduction of the circulating blood cells.The reported in vitro dynamic whole blood test system allowed the sensitive analysis of the hemocompatibility of polymer-based microparticles and was successfully validated for porous PEI microparticles with different water wettabilities. Beyond the qualitative and quantitative analysis of cell-material interactions, the test also allowed the functional evaluation of platelets in whole blood.
Bai, Yu; Castillo, Brian S; Tchakarov, Amanda; Escobar, Miguel A; Cotton, Bryan A; Holcomb, John B; Brown, Robert E
2016-12-01
People of the Jehovah's Witness faith believe that they shall "abstain from blood." Because of this belief, we encounter the challenges from Jehovah's Witness patients who actively seek medical care for themselves and their children, but refuse the transfusion of blood products, which may result in increased morbidity and mortality in this patient population. With the development/availability of new hemostatic/coagulation products and the advances in medical technology, we, in collaboration with our clinical colleagues and our local Jehovah's Witness leadership, have developed a clinical guideline comprising medical protocol and surgical strategy for patients refusing blood products. Included in the medical protocol is an informative handout on related details to help treating physicians and patients make informed decisions about transfusion alternatives. Together, we have entered the medical protocol into the entire Memorial Hermann Hospital's electronic system. We report the detailed development and implementation process in order to share our experience and encourage others to develop their own management plan for this patient population. © 2016 by the Association of Clinical Scientists, Inc.
Wu, Hao; Rodriguez, Ana R; Spur, Bernd W; Venkataraman, Venkat
2016-09-13
A low-cost, easy-to-use and powerful model system is established to evaluate potential treatments that could ameliorate blood retinal barrier breach. An inflammatory factor, histamine, is demonstrated to compromise vessel integrity in the cultured retina through positive staining of IgG outside of the blood vessels. The effects of histamine itself and those of candidate drugs for potential treatments, such as lipoxin A4, are assessed using three parameters: blood vessel leakage via IgG immunostaining, activation of Müller cells via GFAP staining and change in neuronal dendrites through staining for MAP2. Furthermore, the layered organization of the retina allows a detailed analysis of the processes of Müller and ganglion cells, such as changes in width and continuity. While the data presented is with swine retinal culture, the system is applicable to multiple species. Thus, the model provides a reliable tool to investigate the early effects of compromised retinal vessel integrity on different cell types and also to evaluate potential drug candidates for treatment.
CAD system for automatic analysis of CT perfusion maps
NASA Astrophysics Data System (ADS)
Hachaj, T.; Ogiela, M. R.
2011-03-01
In this article, authors present novel algorithms developed for the computer-assisted diagnosis (CAD) system for analysis of dynamic brain perfusion, computer tomography (CT) maps, cerebral blood flow (CBF), and cerebral blood volume (CBV). Those methods perform both quantitative analysis [detection and measurement and description with brain anatomy atlas (AA) of potential asymmetries/lesions] and qualitative analysis (semantic interpretation of visualized symptoms). The semantic interpretation (decision about type of lesion: ischemic/hemorrhagic, is the brain tissue at risk of infraction or not) of visualized symptoms is done by, so-called, cognitive inference processes allowing for reasoning on character of pathological regions based on specialist image knowledge. The whole system is implemented in.NET platform (C# programming language) and can be used on any standard PC computer with.NET framework installed.
[Automatic system control and its application in dialysis].
Santoro, A; Mancini, E; Ferramosca, E
2007-01-01
The progressive increase in the mean age of dialysis patients associated with increasing comorbidity factors such as the presence of cardiovascular disease and diabetes have significantly worsened patients' clinical status and tolerance to hemodialysis. On the other hand, the demand for short treatment times increases the risk of hemodynamic instability as well as inadequate depuration. The traditional management of the dialysis session by setting predefined treatment parameters and carrying out active therapeutic intervention only in the event of complications is definitely unsuitable for short-lasting treatments, which are often complicated by hemodynamic instability, especially in critically ill patients. The first step in improving the management of the dialysis session is the use of uninvasive systems for continuous monitoring of the hemodynamic and biochemical parameters that characterize dialysis quality. In the last decade, special sensors have been designed for continuous measurement of blood volume, blood temperature, blood pressure, heart rate and electrolytes. As a second step, some of these devices have been interfaced with the dialysis equipment, mainly with a view to preventing cardiocirculatory instability but also monitoring the efficiency of dialysis (biofeedback control systems). The basic components of a biofeedback system are the plant, the sensors, the actuators, and the controller. The plant is the biological process we need to control, while the sensors are the devices used for measuring the output variables. The actuators are the working arms of the controller. The controller is the mathematical model that continuously sets the measured output variable against the reference input and modifies the actuators in order to reduce any discrepancies. In actual practice, however, there are a number of conceptual, physical and technological difficulties to overcome. In particular, the behavior of what is to be controlled may be nonlinear and time-varying, with interactions between the actuators and the controlled variable. In such cases, more sophisticated control systems are needed that must be capable of identifying the behavior of the process and continuously update information data while the control is on. These complex systems are called adaptive controllers. At present, there are three biofeedback systems routinely used in clinical dialysis. All of them are aimed at improving the cardiovascular stability during hemodialysis, which at present is one of the main problems limiting the tolerance to treatment on the one hand and the quality of hemodialysis on the other. These systems include biofeedback control of blood volume, biofeedback control of thermal balance, and biofeedback control of blood pressure.
The human cardiovascular system in the absence of gravity
NASA Technical Reports Server (NTRS)
Bungo, M. W.; Charles, J. B.
1985-01-01
The data collected from a Space Shuttle crew to investigate cardiovascular changes due to microgravity are presented. The experimental procedures which involved preflight, immediate postflight, and one week following postflight echocardiograms of 13 individuals are described. The immediate postflight results reveal a 20 percent decrease in stroke volume, a 16 percent decrease in left ventricular diastolic volume index (LVDVI), no change in systolic volume, blood pressure, or cardiac index, and a 24 percent increase in heart rate. One week later a 17 percent stroke volume increase, a 29 percent increase in cardiac index, and normal blood pressure, and LVDVI were observed. It is concluded that upon reexposure to gravity a readaptation process for the cardiovascular system occurs.
A close look at brain dynamics: cells and vessels seen by in vivo two-photon microscopy.
Fumagalli, Stefano; Ortolano, Fabrizio; De Simoni, Maria-Grazia
2014-10-01
The cerebral vasculature has a unique role in providing a constant supply of oxygen and nutrients to ensure normal brain functions. Blood vessels that feed the brain are far from being simply channels for passive transportation of fluids. They form complex structures made up of different cell types. These structures regulate blood supply, local concentrations of O2 and CO2, transport of small molecules, trafficking of plasma cells and fine cerebral functions in normal and diseased brains. Until few years ago, analysis of these functions has been typically based on post mortem techniques, whose interpretation is limited by the need for tissue processing at specific times. For a reliable and effective picture of the dynamic processes in the central nervous system, real-time information in vivo is required. There are now few in vivo systems, among which two-photon microscopy (2-PM) is a truly innovative tool for studying the brain. 2-PM has been used to dissect specific aspects of vascular and immune cell dynamics in the context of neurological diseases, providing exciting results that could not have been obtained with conventional methods. This review summarizes the latest findings on vascular and immune system action in the brain, with particular focus on the dynamic responses after ischemic brain injury. 2-PM has helped define the hierarchical architecture of the brain vasculature, the dynamic interaction between the vasculature and immune cells recruited to lesion sites, the effects of blood flow on neuronal and microglial activity and the ability of cells of the neurovascular unit to regulate blood flow. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nechipurenko, N.; Vasilevskaya, L.; Musienko, J.; Maslova, G.
2007-07-01
It has been studied the intravenous laser irradiation of blood (ILIB) influence with helium-neon laser (HNL) of 630 nm wavelength on some of lipid peroxidation (LPO) and antioxidant system (AOS) findings, aside-base status (ABS) and blood oxygen transport (BOT), state of dermal microhaemodynamics (MGD) in the intact rabbits and after modeling of local ischemia of brain (LIB). Depending on conditions of organism functioning (norm or brain ischaemia) ILIB has resulted in stimulating or normalizing effects on the whole metabolic and microhaemocirculation processes which had been studied during our investigation. It is discussed the mechanisms of pathogenetic directivity of ILIB influence in cerebral ischaemia
Kojic, M; Milosevic, M; Simic, V; Koay, E J; Kojic, N; Ziemys, A; Ferrari, M
2018-05-21
One of the basic and vital processes in living organisms is mass exchange, which occurs on several levels: it goes from blood vessels to cells and organelles within cells. On that path, molecules, as oxygen, metabolic products, drugs, etc. Traverse different macro and micro environments - blood, extracellular/intracellular space, and interior of organelles; and also biological barriers such as walls of blood vessels and membranes of cells and organelles. Many aspects of this mass transport remain unknown, particularly the biophysical mechanisms governing drug delivery. The main research approach relies on laboratory and clinical investigations. In parallel, considerable efforts have been directed to develop computational tools for additional insight into the intricate process of mass exchange and transport. Along these lines, we have recently formulated a composite smeared finite element (CSFE) which is composed of the smeared continuum pressure and concentration fields of the capillary and lymphatic system, and of these fields within tissue. The element offers an elegant and simple procedure which opens up new lines of inquiry and can be applied to large systems such as organs and tumors models. Here, we extend this concept to a multiscale scheme which concurrently couples domains that span from large blood vessels, capillaries and lymph, to cell cytosol and further to organelles of nanometer size. These spatial physical domains are coupled by the appropriate connectivity elements representing biological barriers. The composite finite element has "degrees of freedom" which include pressures and concentrations of all compartments of the vessels-tissue assemblage. The overall model uses the standard, measurable material properties of the continuum biological environments and biological barriers. It can be considered as a framework into which we can incorporate various additional effects (such as electrical or biochemical) for transport through membranes or within cells. This concept and the developed FE software within our package PAK offers a computational tool that can be applied to whole-organ systems, while also including specific domains such as tumors. The solved examples demonstrate the accuracy of this model and its applicability to large biological systems. Copyright © 2018. Published by Elsevier Ltd.
Wang, Hongkai; Ran, Jianhua; Jiang, Tao
2014-01-01
Urea is generated by the urea cycle enzymes, which are mainly in the liver but are also ubiquitously expressed at low levels in other tissues. The metabolic process is altered in several conditions such as by diets, hormones, and diseases. Urea is then eliminated through fluids, especially urine. Blood urea nitrogen (BUN) has been utilized to evaluate renal function for decades. New roles for urea in the urinary system, circulation system, respiratory system, digestive system, nervous system, etc., were reported lately, which suggests clinical significance of urea.
Ross, Nicholas E; Pritchard, Charles J; Rubin, David M; Dusé, Adriano G
2006-05-01
Malaria is a serious global health problem, and rapid, accurate diagnosis is required to control the disease. An image processing algorithm to automate the diagnosis of malaria on thin blood smears is developed. The image classification system is designed to positively identify malaria parasites present in thin blood smears, and differentiate the species of malaria. Images are acquired using a charge-coupled device camera connected to a light microscope. Morphological and novel threshold selection techniques are used to identify erythrocytes (red blood cells) and possible parasites present on microscopic slides. Image features based on colour, texture and the geometry of the cells and parasites are generated, as well as features that make use of a priori knowledge of the classification problem and mimic features used by human technicians. A two-stage tree classifier using backpropogation feedforward neural networks distinguishes between true and false positives, and then diagnoses the species (Plasmodium falciparum, P. vivax, P. ovale or P. malariae) of the infection. Malaria samples obtained from the Department of Clinical Microbiology and Infectious Diseases at the University of the Witwatersrand Medical School are used for training and testing of the system. Infected erythrocytes are positively identified with a sensitivity of 85% and a positive predictive value (PPV) of 81%, which makes the method highly sensitive at diagnosing a complete sample provided many views are analysed. Species were correctly determined for 11 out of 15 samples.
Melatonin, mitochondria and hypertension.
Baltatu, Ovidiu C; Amaral, Fernanda G; Campos, Luciana A; Cipolla-Neto, Jose
2017-11-01
Melatonin, due to its multiple means and mechanisms of action, plays a fundamental role in the regulation of the organismal physiology by fine tunning several functions. The cardiovascular system is an important site of action as melatonin regulates blood pressure both by central and peripheral interventions, in addition to its relation with the renin-angiotensin system. Besides, the systemic management of several processes, melatonin acts on mitochondria regulation to maintain a healthy cardiovascular system. Hypertension affects target organs in different ways and cellular energy metabolism is frequently involved due to mitochondrial alterations that include a rise in reactive oxygen species production and an ATP synthesis decrease. The discussion that follows shows the role played by melatonin in the regulation of mitochondrial physiology in several levels of the cardiovascular system, including brain, heart, kidney, blood vessels and, particularly, regulating the renin-angiotensin system. This discussion shows the putative importance of using melatonin as a therapeutic tool involving its antioxidant potential and its action on mitochondrial physiology in the cardiovascular system.
Automatic Emboli Detection System for the Artificial Heart
NASA Astrophysics Data System (ADS)
Steifer, T.; Lewandowski, M.; Karwat, P.; Gawlikowski, M.
In spite of the progress in material engineering and ventricular assist devices construction, thromboembolism remains the most crucial problem in mechanical heart supporting systems. Therefore, the ability to monitor the patient's blood for clot formation should be considered an important factor in development of heart supporting systems. The well-known methods for automatic embolus detection are based on the monitoring of the ultrasound Doppler signal. A working system utilizing ultrasound Doppler is being developed for the purpose of flow estimation and emboli detection in the clinical artificial heart ReligaHeart EXT. Thesystem will be based on the existing dual channel multi-gate Doppler device with RF digital processing. A specially developed clamp-on cannula probe, equipped with 2 - 4 MHz piezoceramic transducers, enables easy system setup. We present the issuesrelated to the development of automatic emboli detection via Doppler measurements. We consider several algorithms for the flow estimation and emboli detection. We discuss their efficiency and confront them with the requirements of our experimental setup. Theoretical considerations are then met with preliminary experimental findings from a) flow studies with blood mimicking fluid and b) in-vitro flow studies with animal blood. Finally, we discuss some more methodological issues - we consider several possible approaches to the problem of verification of the accuracy of the detection system.
Maksuti, Elira; Westerhof, Nico; Westerhof, Berend E; Broomé, Michael; Stergiopulos, Nikos
2016-01-01
During aging, systolic blood pressure continuously increases over time, whereas diastolic pressure first increases and then slightly decreases after middle age. These pressure changes are usually explained by changes of the arterial system alone (increase in arterial stiffness and vascular resistance). However, we hypothesise that the heart contributes to the age-related blood pressure progression as well. In the present study we quantified the blood pressure changes in normal aging by using a Windkessel model for the arterial system and the time-varying elastance model for the heart, and compared the simulation results with data from the Framingham Heart Study. Parameters representing arterial changes (resistance and stiffness) during aging were based on literature values, whereas parameters representing cardiac changes were computed through physiological rules (compensated hypertrophy and preservation of end-diastolic volume). When taking into account arterial changes only, the systolic and diastolic pressure did not agree well with the population data. Between 20 and 80 years, systolic pressure increased from 100 to 122 mmHg, and diastolic pressure decreased from 76 to 55 mmHg. When taking cardiac adaptations into account as well, systolic and diastolic pressure increased from 100 to 151 mmHg and decreased from 76 to 69 mmHg, respectively. Our results show that not only the arterial system, but also the heart, contributes to the changes in blood pressure during aging. The changes in arterial properties initiate a systolic pressure increase, which in turn initiates a cardiac remodelling process that further augments systolic pressure and mitigates the decrease in diastolic pressure.
NASA Technical Reports Server (NTRS)
Matskevichene, V. B.; Platonova, A. T.
1974-01-01
The effect of a constant magnetic field with a strength of 2500 oersteds on the fibrinogen-fibrin system was studied in the organism of healthy rabbits with exposure times of 1 and 5 hours. The results obtained indicate disruptions in the stage of conversion of fibrinogen to fibrin and an increase in the amount of fibrinogen.
Plasma lipids profile and erythrocytes system in patients with coronary heart disease
NASA Astrophysics Data System (ADS)
Malinova, Lidia I.; Simonenko, Georgy V.; Tuchin, Valery V.; Denisova, Tatyana P.
2006-08-01
Erythrocytes system study can provide a framework for detailed exploration of blood cell-cell and cell-vessel wall interactions, one of the key patterns in blood and vascular pathophysiology. Our objective was to explore erythrocytes system in patients with stable angina pectoris II f.c. (Canadian classification). The participants (N = 56, age 40 - 55 years) without obesity, glucose tolerance violations, lipid lowering drugs treating, heart failure of II and more functional classes (NYHA), coronary episode at least 6 months before study were involved in the study. Blood samples were incubated with glucose solutions of increasing concentrations (from 2.5% to 20% with 2.5% step) during 60 mm (36° C). In prepared blood smears erythrocyte's sizes were studied. Plasma total cholesterol, triglyceride and glucose levels were also measured. Received data were approximated by polynomials of high degree, with after going first and second derivations. Erythrocytes system "behavior" was studied by means of phase pattern constructing. By lipids levels all the patient were divided into five groups: 1) patients with normal lipids levels, 2) patients with borderline total cholesterol level, 3) patients with isolated hypercholesterolemia, 4) patients with isolated hypertriglyceridemia and 5) patients with combined hyperlipidemia. Erythrocytes size lowering process was of set of "stages", which characteristics differ significantly (p > 0.05) in all five groups. Their rate and acceleration characteristics allow us to detect type of lipid profile in patients. Erythrocyte system disturbing by glucose concentration increase show to be most resistant in group of patients with isolated hypercholesterolemia.
Gatica, M C; Monti, G E; Knowles, T G; Gallo, C B
2010-01-09
Two systems for transporting live salmon (Salmo salar) were compared in terms of their effects on blood variables, muscle pH and rigor index: an 'open system' well-boat with recirculated sea water at 13.5 degrees C and a stocking density of 107 kg/m3 during an eight-hour journey, and a 'closed system' well-boat with water chilled from 16.7 to 2.1 degrees C and a stocking density of 243.7 kg/m3 during a seven-hour journey. Groups of 10 fish were sampled at each of four stages: in cages at the farm, in the well-boat after loading, in the well-boat after the journey and before unloading, and in the processing plant after they were pumped from the resting cages. At each sampling, the fish were stunned and bled by gill cutting. Blood samples were taken to measure lactate, osmolality, chloride, sodium, cortisol and glucose, and their muscle pH and rigor index were measured at death and three hours later. In the open system well-boat, the initial muscle pH of the fish decreased at each successive stage, and at the final stage they had a significantly lower initial muscle pH and more rapid onset of rigor than the fish transported on the closed system well-boat. At the final stage all the blood variables except glucose were significantly affected in the fish transported on both types of well-boat.
Bragg, Stefanie A; Armstrong, Kristie C; Xue, Zi-Ling
2012-08-15
A new process to pretreat blood samples has been developed. This process combines the Advanced Oxidation Process (AOP) treatment (using H(2)O(2) and UV irradiation) with acid deactivation of the enzyme catalase in blood. A four-cell reactor has been designed and built in house. The effect of pH on the AOP process has been investigated. The kinetics of the pretreatment process shows that at high C(H(2)O(2),t=0), the reaction is zeroth order with respect to C(H(2)O(2)) and first order with respect to C(blood). The rate limiting process is photon flux from the UV lamp. Degradation of whole blood has been compared with that of pure hemoglobin samples. The AOP pretreatment of the blood samples has led to the subsequent determination of chromium and zinc concentrations in the samples using electrochemical methods. Copyright © 2012 Elsevier B.V. All rights reserved.
Global asymptotic stability and hopf bifurcation for a blood cell production model.
Crauste, Fabien
2006-04-01
We analyze the asymptotic stability of a nonlinear system of two differential equations with delay, describing the dynamics of blood cell produc- tion. This process takes place in the bone marrow, where stem cells differen- tiate throughout division in blood cells. Taking into account an explicit role of the total population of hematopoietic stem cells in the introduction of cells in cycle, we are led to study a characteristic equation with delay-dependent coefficients. We determine a necessary and sufficient condition for the global stability of the first steady state of our model, which describes the popula- tion's dying out, and we obtain the existence of a Hopf bifurcation for the only nontrivial positive steady state, leading to the existence of periodic solutions. These latter are related to dynamical diseases affecting blood cells known for their cyclic nature.
Gasomediators (·NO, CO, and H₂S) and their role in hemostasis and thrombosis.
Olas, Beata
2015-05-20
Hemostasis is a group of mechanisms used to prevent the outflow of blood from its vessels, and to ensure its liquidity and flow within them. The system incorporates aspects of the blood vessel wall (mainly the intima), the clotting process, together with its factors (i.e. fibrinogen) and coagulation inhibitors, as well as fibrinolysis, blood platelets and the phagocyte system. The modulation of hemostasis is associated with the pathogenesis of cardiovascular diseases, such as thrombosis. The study examines the action of three selected gasomediators, nitric oxide ((•)NO), carbon monoxide (CO) and hydrogen sulfide (H2S), on hemostasis and thrombosis, although these gasses are also involved in a multitude of other physiological functions. (•)NO inhibits blood platelet activation, relaxes blood vessels and, as a free radical chain, may rapidly react with superoxide anion (O2(-•)) in blood platelets to form peroxynitrite (ONOO(-)). ONOO(-) is a reactive nitrating and nitrosating agent which induces oxidative/nitrative stress in blood platelets and plasma. Moreover, ONOO(-) changes the structure and function of fibrinogen and proteins associated with fibrinolysis. Recently, proteomic studies have provided unequivocal evidence that human platelets lack any expression of nitric oxide synthase isoforms. Other studies have demonstrated that CO and H2S, reduce blood platelet reactivity. Moreover, H2S has been reported to demonstrate anticoagulatory activity, and CO may act not only as an anticoagulant, but also aprocoagulant. This review article summarizes current knowledge of the biological roles of gasomediators (NO, CO, H2S) in hemostasis and in cardiovascular diseases. Copyright © 2015 Elsevier B.V. All rights reserved.
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 862.1130 - Blood volume test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Blood volume test system. 862.1130 Section 862....1130 Blood volume test system. (a) Identification. A blood volume test system is a device intended to measure the circulating blood volume. Blood volume measurements are used in the diagnosis and treatment of...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9125 - Vacuum-assisted blood collection system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-assisted blood collection system. 864.9125... Blood and Blood Products § 864.9125 Vacuum-assisted blood collection system. (a) Identification. A vacuum-assisted blood collection system is a device intended for medical purposes that uses a vacuum to...
21 CFR 864.9175 - Automated blood grouping and antibody test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... Manufacture Blood and Blood Products § 864.9175 Automated blood grouping and antibody test system. (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Automated blood grouping and antibody test system...
21 CFR 864.9175 - Automated blood grouping and antibody test system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Manufacture Blood and Blood Products § 864.9175 Automated blood grouping and antibody test system. (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood grouping and antibody test system...
21 CFR 864.9175 - Automated blood grouping and antibody test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Manufacture Blood and Blood Products § 864.9175 Automated blood grouping and antibody test system. (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated blood grouping and antibody test system...
21 CFR 864.9175 - Automated blood grouping and antibody test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... Manufacture Blood and Blood Products § 864.9175 Automated blood grouping and antibody test system. (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Automated blood grouping and antibody test system...
21 CFR 864.9175 - Automated blood grouping and antibody test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... Manufacture Blood and Blood Products § 864.9175 Automated blood grouping and antibody test system. (a) Identification. An automated blood grouping and antibody test system is a device used to group erythrocytes (red... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Automated blood grouping and antibody test system...
Applying radio-frequency identification (RFID) technology in transfusion medicine.
Hohberger, Clive; Davis, Rodeina; Briggs, Lynne; Gutierrez, Alfonso; Veeramani, Dhamaraj
2012-05-01
ISO/IEC 18000-3 mode 1 standard 13.56 MHz RFID tags have been accepted by the International Society for Blood Transfusion (ISBT) and the United States Food and Drug Administration (FDA) as data carriers to integrate with and augment ISBT 128 barcode data carried on blood products. The use of 13.56 MHz RFID carrying ISBT 128 data structures allows the global deployment and use of RFID, supporting both international transfer of blood and international disaster relief. The deployment in process at the BloodCenter of Wisconsin and testing at the University of Iowa Health Center is the first FDA-permitted implementation of RFID throughout in all phases of blood banking, donation through transfusion. RFID technology and equipment selection will be discussed along with FDA-required RF safety testing; integration with the blood enterprise computing system and required RFID tag performance. Tag design and survivability is an issue due to blood bag centrifugation and irradiation. Deployment issues will be discussed. Use of RFID results in significant return on investment over the use of barcodes in the blood center operations through labor savings and error reduction. Copyright © 2011 The International Alliance for Biological Standardization. Published by Elsevier Ltd. All rights reserved.
Toward unstained cytology and complete blood counts at the point of care (Conference Presentation)
NASA Astrophysics Data System (ADS)
Zuluaga, Andres F.; Pierce, Mark C.; MacAulay, Calum E.
2017-02-01
Cytology tests, whether performed on body fluids, aspirates, or scrapings are commonly used to detect, diagnose, and monitor a wide variety of health conditions. Complete blood counts (CBCs) quantify the number of red and white blood cells in a blood volume, as well as the different types of white blood cells. There is a critical unmet need for an instrument that can perform CBCs at the point of care (POC), and there is currently no product in the US that can perform this test at the bedside. We have developed a system that is capable of tomographic images with sub-cellular resolution with consumer-grade broadband (LED) sources and CMOS detectors suitable for POC implementation of CBC tests. The systems consists of cascaded static Michelson and Sagnac interferometers that map phase (encoding depth) and a transverse spatial dimension onto a two-dimensional output plane. Our approach requires a 5 microliter sample, can be performed in 5 minutes or less, and does not require staining or other processing as it relies on intrinsic contrast. We will show results directly imaging and differentiating unstained blood cells using supercontinuum fiber lasers and LEDs as sources and CMOS cameras as sensors. We will also lay out the follow up steps needed, including image segmentation, analysis and classification, to verify performance and advance toward CBCs that can be performed bedside and do not require CLIA-certified laboratories.
Liu, Xu; Huang, Xiwei; Jiang, Yu; Xu, Hang; Guo, Jing; Hou, Han Wei; Yan, Mei; Yu, Hao
2017-08-01
Based on a 3.2-Megapixel 1.1- μm-pitch super-resolution (SR) CMOS image sensor in a 65-nm backside-illumination process, a lens-free microfluidic cytometer for complete blood count (CBC) is demonstrated in this paper. Backside-illumination improves resolution and contrast at the device level with elimination of surface treatment when integrated with microfluidic channels. A single-frame machine-learning-based SR processing is further realized at system level for resolution correction with minimum hardware resources. The demonstrated microfluidic cytometer can detect the platelet cells (< 2 μm) required in CBC, hence is promising for point-of-care diagnostics.
Antfolk, Maria; Kim, Soo Hyeon; Koizumi, Saori; Fujii, Teruo; Laurell, Thomas
2017-01-01
The incidence of cancer is increasing worldwide and metastatic disease, through the spread of circulating tumor cells (CTCs), is responsible for the majority of the cancer deaths. Accurate monitoring of CTC levels in blood provides clinical information supporting therapeutic decision making, and improved methods for CTC enumeration are asked for. Microfluidics has been extensively used for this purpose but most methods require several post-separation processing steps including concentration of the sample before analysis. This induces a high risk of sample loss of the collected rare cells. Here, an integrated system is presented that efficiently eliminates this risk by integrating label-free separation with single cell arraying of the target cell population, enabling direct on-chip tumor cell identification and enumeration. Prostate cancer cells (DU145) spiked into a sample with whole blood concentration of the peripheral blood mononuclear cell (PBMC) fraction were efficiently separated and trapped at a recovery of 76.2 ± 5.9% of the cancer cells and a minute contamination of 0.12 ± 0.04% PBMCs while simultaneously enabling a 20x volumetric concentration. This constitutes a first step towards a fully integrated system for rapid label-free separation and on-chip phenotypic characterization of circulating tumor cells from peripheral venous blood in clinical practice. PMID:28425472
Antfolk, Maria; Kim, Soo Hyeon; Koizumi, Saori; Fujii, Teruo; Laurell, Thomas
2017-04-20
The incidence of cancer is increasing worldwide and metastatic disease, through the spread of circulating tumor cells (CTCs), is responsible for the majority of the cancer deaths. Accurate monitoring of CTC levels in blood provides clinical information supporting therapeutic decision making, and improved methods for CTC enumeration are asked for. Microfluidics has been extensively used for this purpose but most methods require several post-separation processing steps including concentration of the sample before analysis. This induces a high risk of sample loss of the collected rare cells. Here, an integrated system is presented that efficiently eliminates this risk by integrating label-free separation with single cell arraying of the target cell population, enabling direct on-chip tumor cell identification and enumeration. Prostate cancer cells (DU145) spiked into a sample with whole blood concentration of the peripheral blood mononuclear cell (PBMC) fraction were efficiently separated and trapped at a recovery of 76.2 ± 5.9% of the cancer cells and a minute contamination of 0.12 ± 0.04% PBMCs while simultaneously enabling a 20x volumetric concentration. This constitutes a first step towards a fully integrated system for rapid label-free separation and on-chip phenotypic characterization of circulating tumor cells from peripheral venous blood in clinical practice.
NASA Astrophysics Data System (ADS)
Lo, Men-Tzung; Hu, Kun; Liu, Yanhui; Peng, C.-K.; Novak, Vera
2008-12-01
Quantification of nonlinear interactions between two nonstationary signals presents a computational challenge in different research fields, especially for assessments of physiological systems. Traditional approaches that are based on theories of stationary signals cannot resolve nonstationarity-related issues and, thus, cannot reliably assess nonlinear interactions in physiological systems. In this review we discuss a new technique called multimodal pressure flow (MMPF) method that utilizes Hilbert-Huang transformation to quantify interaction between nonstationary cerebral blood flow velocity (BFV) and blood pressure (BP) for the assessment of dynamic cerebral autoregulation (CA). CA is an important mechanism responsible for controlling cerebral blood flow in responses to fluctuations in systemic BP within a few heart-beats. The MMPF analysis decomposes BP and BFV signals into multiple empirical modes adaptively so that the fluctuations caused by a specific physiologic process can be represented in a corresponding empirical mode. Using this technique, we showed that dynamic CA can be characterized by specific phase delays between the decomposed BP and BFV oscillations, and that the phase shifts are significantly reduced in hypertensive, diabetics and stroke subjects with impaired CA. Additionally, the new technique can reliably assess CA using both induced BP/BFV oscillations during clinical tests and spontaneous BP/BFV fluctuations during resting conditions.
Profiling wrist pulse from skin surface by Advanced Vibrometer Interferometer Device
NASA Astrophysics Data System (ADS)
Lee, Hao-Xiang; Lee, Shu-Sheng; Hsu, Yu-Hsiang; Lee, Chih-Kung
2017-02-01
With global trends in population aging, the need to decrease and prevent the onset of cardiovascular disease has drawn a great attention. The traditional cuff-based upper arm sphygmomanometer is still the standard method to retrieve blood pressure information for diagnostics. However, this method is not easy to be adapted by patients and is not comfortable enough to perform a long term monitoring process. In order to correlate the beating profile of the arterial pulse on the wrist skin, an Advanced Vibrometer Interferometer Device (AVID) is adopted in this study to measure the vibration amplitude of skin and compare it with blood pressure measured from the upper arm. The AVID system can measure vibration and remove the directional ambiguity by using circular polarization interferometer technique with two orthogonal polarized light beams. The displacement resolution of the system is nearly 1.0 nm and the accuracy is experimentally verified. Using an optical method to quantify wrist pule, it provides a means to perform cuff-less, noninvasive and continuous measurement. In this paper, the correlations between the amplitude of skin vibration and the actual blood pressure is studied. The success of this method could potentially set the foundation of blood pressure monitor system based on optical approaches.
Leitão, Alexandre B; Sucena, Élio
2015-01-01
Virtually all species of coelomate animals contain blood cells that display a division of labor necessary for homeostasis. This functional partition depends upon the balance between proliferation and differentiation mostly accomplished in the hematopoietic organs. In Drosophila melanogaster, the lymph gland produces plasmatocytes and crystal cells that are not released until pupariation. Yet, throughout larval development, both hemocyte types increase in numbers. Mature plasmatocytes can proliferate but it is not known if crystal cell numbers increase by self-renewal or by de novo differentiation. We show that new crystal cells in third instar larvae originate through a Notch-dependent process of plasmatocyte transdifferentiation. This process occurs in the sessile clusters and is contingent upon the integrity of these structures. The existence of this hematopoietic tissue, relying on structure-dependent signaling events to promote blood homeostasis, creates a new paradigm for addressing outstanding questions in Drosophila hematopoiesis and establishing further parallels with vertebrate systems. DOI: http://dx.doi.org/10.7554/eLife.06166.001 PMID:25650737
Dokhnadze, T D
2011-06-01
The impact of therapeutic Akhtala muds and electromagnetic radiation of millimeter range on biochemical indices in patients with post discectomy syndrome has been investigated. The research showed that medical rehabilitation with Akhtala medical muds and electromagnetic radiation of millimeter range stimulates sympathetic-adrenal system, adrenocorticotrophic function of the hypophysis and glucocorticoid function of adrenal cortex, induces a weakening/removal of an inflammatory process in the operated area, enhances antioxidant defense of the organism, oppresses calcium metabolism and peroxide oxidation of lipids. The noted positive process was manifested in the increase up to upper limit of the norm of daily excretion of adrenalin and noradrenalin, the content of adrenocorticotrophic hormone and cortisol in blood plasma and in the decrease of the amount of malonic dialdehyde in it, also in the increase of antioxidative activity of blood plasma, in the decrease of the content of "С"-reactive protein, haptoglobin, seroglicoids, common and ionic calcium in blood serum.
Baran, Arkadiusz; Jakiel, Grzegorz; Wójcik, Grazyna
2008-01-01
The adaptation of an organism to a change in environmental conditions is a complex and in some aspects a poorly understood physiological process. The activating influence of stress on the sympathetic nervous system, the hypothalamic - pituitary - adrenal axis and the suppression of TSH, LH, FSH release is well known. The interplay of communication between the endocrine and immune systems plays an essential role in modulating the response to stress related mediators. The basis of many contradictory and incoherent results of experiments is due to the various methodologies of creating changes in environmental conditions, the way of collecting blood samples which influence stress mediators, the case of assessing the influence of many factors on reproductive functions and the performance of experiments without synchronization with the reproductive cycle. The review will focus on the presentation of simple and repeatable methods of development of an adaptation stress to changed environmental conditions (temperature, oxygenation, humidity) and the technique of blood collection during hour-long estimation of interactions between the endocrine, nervous and immune systems. We would like to place emphasis on appropriate ways of performing experiments on female rats, with regards to the choice of a suitable phase of the reproductive cycle. Also on ways of anaesthesia and microsurgical techniques of vein catheterisation for repeated blood sampling. The performance of all phases of the experiment allow us to estimate only the influence of environmental conditions and eliminate interfering factors during the process of preparing animal for the experiment.
Rapid identification of bacteria from bioMérieux BacT/ALERT blood culture bottles by MALDI-TOF MS.
Haigh, J D; Green, I M; Ball, D; Eydmann, M; Millar, M; Wilks, M
2013-01-01
Several studies have reported poor results when trying to identify microorganisms directly from the bioMérieux BacT/ALERT blood culture system using matrix-assisted laser desorption/ionisation-time of flight (MALDI-TOF) mass spectrometry. The aim of this study is to evaluate two new methods, Sepsityper and an enrichment method for direct identification of microorganisms from this system. For both methods the samples were processed using the Bruker Microflex LT mass spectrometer (Biotyper) using the Microflex Control software to obtain spectra. The results from direct analysis were compared with those obtained by subculture and subsequent identification. A total of 350 positive blood cultures were processed simultaneously by the two methods. Fifty-three cultures were polymocrobial or failed to grow any organism on subculture, and these results were not included as there was either no subculture result, or for polymicrobial cultures it was known that the Biotyper would not be able to distinguish the constituent organisms correctly. Overall, the results showed that, contrary to previous reports, it is possible to identify bacteria directly from bioMérieux blood culture bottles, as 219/297 (74%) correct identifications were obtained using the Bruker Sepsityper method and 228/297 (77%) were obtained for the enrichment method when there is only one organism was present. Although the enrichment method was simpler, the reagent costs for the Sepsityper method were approximately pound 4.00 per sample compared to pound 0.50. An even simpler and cheaper method, which was less labour-intensive and did not require further reagents, was investigated. Seventy-seven specimens from positive signalled blood cultures were analysed by inoculating prewarmed blood agar plates and analysing any growth after 1-, 2- and 4-h periods of incubation at 37 degrees C, by either direct transfer or alcohol extraction. This method gave the highest number of correct identifications, 66/77 (86%), and was cheaper and less labour-intensive than either of the two above methods.
Schmidt, Bernd; Reinicke, Dana; Reindl, Iris; Bork, Ines; Wollschläger, Bettina; Lambrecht, Nina; Fleischhacker, Michael
2017-06-01
In most research laboratories the use of EDTA tubes for the isolation of plasma DNA from tumor patients is standard. Unfortunately these tubes do not allow for an extended storage of samples before processing and prevent EDTA tubes from being shipped at ambient temperature. The aim of our study was to compare the quantity and quality of plasma DNA isolated from EDTA and PAXgene® Blood ccfDNA Tubes in different downstream applications. We enrolled 29 patients in our study. Blood samples were drawn into EDTA and PAXgene® Blood ccfDNA Tubes and were processed on day 0 and day 7 after storage at ambient temperature. The plasma DNA from 10 patients was isolated manually. For the DNA isolation from the plasma of 19 additional patients we used the automated QIAsymphony system. The total amount DNA from all samples was measured with a quantitative real-time PCR assay. In addition the amount of methylated mSHOX2 plasma DNA was determined. While the 7day storage lead to an increased amount of total DNA in almost all EDTA tubes, this effect was only seen in very few PAXgene® Blood ccfDNA Tubes. The stabilization solution which prevents the lysis of blood cells had no effect on the method for quantification of methylated sequences in these samples. The quantity and quality of plasma DNA from both types of blood draw tubes are comparable. DNA from PAXgene® Blood ccfDNA was successfully used for PCR-based quantification of total amount of cell-free DNA and for methylation analysis as well. Copyright © 2017 Elsevier B.V. All rights reserved.
Sakota, Daisuke; Murashige, Tomotaka; Kosaka, Ryo; Fujiwara, Tatsuki; Nishida, Masahiro; Maruyama, Osamu
2015-08-01
Understanding the thrombus formation in cardiovascular devices such as rotary blood pumps is the most important issue in developing more hemocompatible devices. The objective of this study was to develop a hyperspectral imaging (HSI) method to visualize the thrombus growth process within a rotary blood pump and investigate the optical properties of the thrombus. An in vitro thrombogenic test was conducted using fresh porcine blood and a specially designed hydrodynamically levitated centrifugal blood pump with a transparent bottom. The pump rotating at 3000 rpm circulated the blood at 1.0 L/min. The bottom surface of the pump was illuminated with white light pulsed at the same frequency as the pump rotation, and the backward-scattered light was imaged using the HSI system. Using stroboscopic HSI and an image construction algorithm, dynamic spectral imaging at wavelengths ranging from 608 to 752 nm within the rotating pump was achieved. After completing the experiment, we collected the red thrombus formed in the pump impeller and quantified the thrombus hemoglobin concentration (Hbthrombus ). The spectrum changed around the center of the impeller, and the area of change expanded toward the impeller flow path. The shape corresponded approximately to the shape of the thrombus. The spectrum change indicated that the light scattering derived from red blood cells decreased. The Hbthrombus was 4.7 ± 1.3 g/dL versus a total hemoglobin of 13 ± 0.87 g/dL. The study revealed that Hbthrombus was reduced by the surrounding blood flow. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Morphology of drying blood pools
NASA Astrophysics Data System (ADS)
Laan, Nick; Smith, Fiona; Nicloux, Celine; Brutin, David; D-Blood project Collaboration
2016-11-01
Often blood pools are found on crime scenes providing information concerning the events and sequence of events that took place on the scene. However, there is a lack of knowledge concerning the drying dynamics of blood pools. This study focuses on the drying process of blood pools to determine what relevant information can be obtained for the forensic application. We recorded the drying process of blood pools with a camera and measured the weight. We found that the drying process can be separated into five different: coagulation, gelation, rim desiccation, centre desiccation, and final desiccation. Moreover, we found that the weight of the blood pool diminishes similarly and in a reproducible way for blood pools created in various conditions. In addition, we verify that the size of the blood pools is directly related to its volume and the wettability of the surface. Our study clearly shows that blood pools dry in a reproducible fashion. This preliminary work highlights the difficult task that represents blood pool analysis in forensic investigations, and how internal and external parameters influence its dynamics. We conclude that understanding the drying process dynamics would be advancement in timeline reconstitution of events. ANR funded project: D-Blood Project.
Sutton, N; Tracey, M C; Johnston, I D; Greenaway, R S; Rampling, M W
1997-05-01
A novel instrument has been developed to study the microrheology of erythrocytes as they flow through channels of dimensions similar to human blood capillaries. The channels are produced in silicon substrates using microengineering technology. Accurately defined, physiological driving pressures and temperatures are employed whilst precise, real-time image processing allows individual cells to be monitored continuously during their transit. The instrument characterises each cell in a sample of ca. 1000 in terms of its volume and flow velocity profile during its transit through a channel. The unique representation of the data in volume/velocity space provides new insight into the microrheological behaviour of blood. The image processing and subsequent data analysis enable the system to reject anomalous events such as multiple cell transits, thereby ensuring integrity of the resulting data. By employing an array of microfluidic flow channels we can integrate a number of different but precise and highly reproducible channel sizes and geometries within one array, thereby allowing multiple, concurrent isobaric measurements on one sample. As an illustration of the performance of the system, volume/velocity data sets recorded in a microfluidic device incorporating multiple channels of 100 microns length and individual widths ranging between 3.0 and 4.0 microns are presented.
Ghane, Narjes; Vard, Alireza; Talebi, Ardeshir; Nematollahy, Pardis
2017-01-01
Recognition of white blood cells (WBCs) is the first step to diagnose some particular diseases such as acquired immune deficiency syndrome, leukemia, and other blood-related diseases that are usually done by pathologists using an optical microscope. This process is time-consuming, extremely tedious, and expensive and needs experienced experts in this field. Thus, a computer-aided diagnosis system that assists pathologists in the diagnostic process can be so effective. Segmentation of WBCs is usually a first step in developing a computer-aided diagnosis system. The main purpose of this paper is to segment WBCs from microscopic images. For this purpose, we present a novel combination of thresholding, k-means clustering, and modified watershed algorithms in three stages including (1) segmentation of WBCs from a microscopic image, (2) extraction of nuclei from cell's image, and (3) separation of overlapping cells and nuclei. The evaluation results of the proposed method show that similarity measures, precision, and sensitivity respectively were 92.07, 96.07, and 94.30% for nucleus segmentation and 92.93, 97.41, and 93.78% for cell segmentation. In addition, statistical analysis presents high similarity between manual segmentation and the results obtained by the proposed method.
Algorithms and Results of Eye Tissues Differentiation Based on RF Ultrasound
Jurkonis, R.; Janušauskas, A.; Marozas, V.; Jegelevičius, D.; Daukantas, S.; Patašius, M.; Paunksnis, A.; Lukoševičius, A.
2012-01-01
Algorithms and software were developed for analysis of B-scan ultrasonic signals acquired from commercial diagnostic ultrasound system. The algorithms process raw ultrasonic signals in backscattered spectrum domain, which is obtained using two time-frequency methods: short-time Fourier and Hilbert-Huang transformations. The signals from selected regions of eye tissues are characterized by parameters: B-scan envelope amplitude, approximated spectral slope, approximated spectral intercept, mean instantaneous frequency, mean instantaneous bandwidth, and parameters of Nakagami distribution characterizing Hilbert-Huang transformation output. The backscattered ultrasound signal parameters characterizing intraocular and orbit tissues were processed by decision tree data mining algorithm. The pilot trial proved that applied methods are able to correctly classify signals from corpus vitreum blood, extraocular muscle, and orbit tissues. In 26 cases of ocular tissues classification, one error occurred, when tissues were classified into classes of corpus vitreum blood, extraocular muscle, and orbit tissue. In this pilot classification parameters of spectral intercept and Nakagami parameter for instantaneous frequencies distribution of the 1st intrinsic mode function were found specific for corpus vitreum blood, orbit and extraocular muscle tissues. We conclude that ultrasound data should be further collected in clinical database to establish background for decision support system for ocular tissue noninvasive differentiation. PMID:22654643
Pereira, Jefferson Rodrigues; Sousa, Caissa Veloso E; Matos, Eliane Bragança de; Rezende, Leonardo Benedito Oliveira; Bueno, Natália Xavier; Dias, Álvaro Machado
2016-08-01
Currently, in Brazil, 1.78% of the population area blood donors, a level lower than the ideal one that, according to WHO, should be between 3% and 5% of the population. Following this scenario, the current study has a general goal of identifying and analyzing the main critical factors of the process of blood donation in the city of Belo Horizonte, MG, under the perception of donors, potential donors and non donors. A qualitative research approach was conducted, through twenty-four semi-structured interviews. The results highlight the lack of information in the various stages of the blood donation system. During the stages of donor recruitment and awareness, communication actions convey to society incomplete information about the donation process, discouraging future actions of donation. On the other hand, a lack of appreciation of the donation experience and the construction of social values associated with the donor prevent the multiplication of social behaviors for donation. The results of this study, found from theoretical framework outlined in this study, highlight the causes or critical factors that impede changes in behavior, incremental or radical, proposed by social marketing.
Maurer-Spurej, Elisabeth; Larsen, Rune; Labrie, Audrey; Heaton, Andrew; Chipperfield, Kate
2016-08-01
In circulation, shedding of microparticles from a variety of viable cells can be triggered by pathological activation of inflammatory processes, by activation of coagulation or complement systems, or by physical stress. Elevated microparticle content (MPC) in donor blood might therefore indicate a clinical condition of the donor which, upon transfusion, might affect the recipient. In blood products, elevated MPC might also represent product stress. Surprisingly, the MPC in blood collected from normal blood donors is highly variable, which raises the question whether donor microparticles are present in-vivo and transfer into the final blood component, and how production methods and post-production processing might affect the MPC. We measured MPC using ThromboLUX in (a) platelet-rich plasma (PRP) of 54 apheresis donors and the corresponding apheresis products, (b) 651 apheresis and 646 pooled platelet concentrates (PCs) with plasma and 414 apheresis PCs in platelet additive solution (PAS), and (c) apheresis PCs before and after transportation, gamma irradiation, and pathogen inactivation (N = 8, 7, and 12 respectively). ThromboLUX-measured MPC in donor PRP and their corresponding apheresis PC samples were highly correlated (r = 0.82, P = .001). The average MPC in pooled PC was slightly lower than that in apheresis PC and substantially lower in apheresis PC stored with PAS rather than plasma. Mirasol Pathogen Reduction treatment significantly increased MPC with age. Thus, MPC measured in donor samples might be a useful predictor of product stability, especially if post-production processes are necessary. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Zeng, Zhijun; Huo, Xia; Zhang, Yu; Xiao, Zhehong; Zhang, Yuling; Xu, Xijin
2018-05-12
Environmental lead exposure leads to various deleterious effects on multiple organs and systems, including the hematopoietic system. To explore the effects of lead exposure on platelet indices in preschool children from an informal, lead-contaminated electronic waste (e-waste) recycling area, we collected venous blood samples from 466 preschool children (331 from an e-waste area (Guiyu) and 135 from a non-e-waste area (Haojiang)). Child blood lead levels (BLLs) were determined by graphite furnace atomic absorption spectrophotometry, while platelet indices were quantified using a Sysmex XT-1800i hematology analyzer. Higher blood lead levels are observed in e-waste lead-exposed preschool children. Significant relationships between high blood lead levels (exceeding current health limits) and elevated platelet count (PLT), plateletcrit (PCT), mean platelet volume (MPV), and platelet large cell ratio (P-LCR) were also uncovered. Furthermore, the median PLT and PCT levels of children from the exposed group both exceeded the respective recommended maximum reference range value, whereas the reference group did not. Location of child residence in Guiyu and BLLs were both risk factors related to platelet indices. These results suggest that high blood lead exposure from e-waste recycling may increase the risk of an amplified coagulation process through the activation of platelets in preschool children.
Belova, L A
2012-01-01
We studied 209 patients with chronic brain ischemia due to arterial hypertension (hypertonic encephalopathy). 93 patients (44.5%) had clinical-anamnestic features of constitutional phlebopathy and 116 (55.5%) had not. Based on the conception of 5 functional-morphological levels of the vascular brain system, a complex ultrasound study was conducted. The control group included 30 people without cerebrovascular pathology. In hypertonic encephalopathy, pathological processes developing in the 1st and 2nd structural-functional levels (extra- and intracerebral arteries) correspond to remodeling, that is characteristic of arterial hypertension, and do not depend on the presence of the constitutional venous insufficiency. Changes in parameters of the blood flow in the 3rd, 4th and 5th structural-functional levels of the brain's blood supply (microcirculatory bed, head venous system, jugular and spine veins) form a dopplerographic pattern of the cerebral venous dyscirculation which is mostly pronounced in constitutional phlebopathy in patients with hypertonic encephalopathy. This pattern includes the reduction of linear blood flow velocity in nitroglycerine test, lower values of the resistance index and the increase in the linear blood flow velocity in the sinus transversus and Rosenthal vein, lack of ostial valves of the inner jugular veinas well as the decrease of linear and increase in the volume blood flow velocity along it. The methodology of the system approach based on using clinical and instrumental method in the study of cerebral hemodynamics is important for treatment optimization in patients with chronic brain ischemia.
Genomic Indicators in the blood predict drug-induced liver injury
Hepatotoxicity and other forms of liver injury stemming from exposure to toxicants and idiosyncratic drug reactions are major concerns during the drug discovery process. Animal model systems have been utilized in an attempt to extrapolate the risk of harmful agents to humans and...
Multifractality of cerebral blood flow
NASA Astrophysics Data System (ADS)
West, Bruce J.; Latka, Miroslaw; Glaubic-Latka, Marta; Latka, Dariusz
2003-02-01
Scale invariance, the property relating time series across multiple scales, has provided a new perspective of physiological phenomena and their underlying control systems. The traditional “signal plus noise” paradigm of the engineer was first replaced with a model in which biological time series have a fractal structure in time (Fractal Physiology, Oxford University Press, Oxford, 1994). This new paradigm was subsequently shown to be overly restrictive when certain physiological signals were found to be characterized by more than one scaling parameter and therefore to belong to a class of more complex processes known as multifractals (Fractals, Plenum Press, New York, 1988). Here we demonstrate that in addition to heart rate (Nature 399 (1999) 461) and human gait (Phys. Rev. E, submitted for publication), the nonlinear control system for cerebral blood flow (CBF) (Phys. Rev. Lett., submitted for publication; Phys. Rev. E 59 (1999) 3492) is multifractal. We also find that this multifractality is greatly reduced for subjects with “serious” migraine and we present a simple model for the underlying control process to describe this effect.
Monitoring of Vital Signs with Flexible and Wearable Medical Devices.
Khan, Yasser; Ostfeld, Aminy E; Lochner, Claire M; Pierre, Adrien; Arias, Ana C
2016-06-01
Advances in wireless technologies, low-power electronics, the internet of things, and in the domain of connected health are driving innovations in wearable medical devices at a tremendous pace. Wearable sensor systems composed of flexible and stretchable materials have the potential to better interface to the human skin, whereas silicon-based electronics are extremely efficient in sensor data processing and transmission. Therefore, flexible and stretchable sensors combined with low-power silicon-based electronics are a viable and efficient approach for medical monitoring. Flexible medical devices designed for monitoring human vital signs, such as body temperature, heart rate, respiration rate, blood pressure, pulse oxygenation, and blood glucose have applications in both fitness monitoring and medical diagnostics. As a review of the latest development in flexible and wearable human vitals sensors, the essential components required for vitals sensors are outlined and discussed here, including the reported sensor systems, sensing mechanisms, sensor fabrication, power, and data processing requirements. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Brand, Peter; Bauer, Marcus; Gube, Monika; Lenz, Klaus; Reisgen, Uwe; Spiegel-Ciobanu, Vilia Elena; Kraus, Thomas
2014-01-01
It has been shown that exposure of subjects to emissions from a metal inert gas (MIG) brazing process of zinc-coated material led to an increase of high-sensitivity C-reactive protein (hsCRP) in the blood. In this study, the no-observed-effect level (NOEL) for such emissions was assessed. Twelve healthy subjects were exposed for 6 hours to different concentrations of MIG brazing fumes under controlled conditions. High-sensitivity C-reactive protein was measured in the blood. For welding fumes containing 1.20 and 1.50 mg m zinc, high-sensitivity C-reactive protein was increased the day after exposure. For 0.90 mg m zinc, no increase was detected. These data indicate that the no-observed-effect level for emissions from a MIG brazing process of zinc-coated material in respect to systemic inflammation is found for welding fumes with zinc concentrations between 0.90 and 1.20 mg m.
Role of Proangiogenic Factors in Immunopathogenesis of Multiple Sclerosis.
Hamid, Kabir Magaji; Mirshafiey, Abbas
2016-02-01
Angiogenesis is a complex and balanced process in which new blood vessels form from preexisting ones by sprouting, splitting, growth and remodeling. This phenomenon plays a vital role in many physiological and pathological processes. However, the disturbance in physiological process can play a role in pathogenesis of some chronic inflammatory diseases, including multiple sclerosis (MS) in human and its animal model. Although the relation between abnormal blood vessels and MS lesions was established in previous studies, but the role of pathological angiogenesis remains unclear. In this study, the link between proangiogenic factors and multiple sclerosis pathogenesis was examined by conducting a systemic review. Thus we searched the English medical literature via PubMed, ISI web of knowledge, Medline and virtual health library (VHL) databases. In this review, we describe direct and indirect roles of some proangiogenic factors in MS pathogenesis and report the association of these factors with pathological and inflammatory angiogenesis.
Sherman, L A
1999-07-01
Outcomes data in medicine can be limited by subjective methodologic issues such as poor selection of end points and use of nonvalidated systems for quality adjustment. Blood transfusion analyses are further complicated by the fact that transfusion seldom is primary therapy but is usually supportive or adjunctive. Thus, much of the outcome data in transfusion medicine are either unavailable or in one of two areas. The first area is prevention of bad sequelae of various cytopenias or factor deficiencies. The second is decreasing adverse effects of transfusion itself. A different useful area for outcome and root cause approaches in individual institutions is examining preanalytical and postanalytical processes of their own. Examples are sample labeling accuracy, quality and timeliness of blood suppliers, internal delivery processes and times, and product wastage. Use review can be changed to real time from retrospective time. By reducing complaints about service to objective data, realistic change can be made in internal and external processes.
Improving preanalytic processes using the principles of lean production (Toyota Production System).
Persoon, Thomas J; Zaleski, Sue; Frerichs, Janice
2006-01-01
The basic technologies used in preanalytic processes for chemistry tests have been mature for a long time, and improvements in preanalytic processes have lagged behind improvements in analytic and postanalytic processes. We describe our successful efforts to improve chemistry test turnaround time from a central laboratory by improving preanalytic processes, using existing resources and the principles of lean production. Our goal is to report 80% of chemistry tests in less than 1 hour and to no longer recognize a distinction between expedited and routine testing. We used principles of lean production (the Toyota Production System) to redesign preanalytic processes. The redesigned preanalytic process has fewer steps and uses 1-piece flow to move blood samples through the accessioning, centrifugation, and aliquoting processes. Median preanalytic processing time was reduced from 29 to 19 minutes, and the laboratory met the goal of reporting 80% of chemistry results in less than 1 hour for 11 consecutive months.
Trofimov, M V
2014-07-01
Examination of patients, suffering gastroduodenal ulcer, complicated by hemorrhage, was conducted, using clinical, microbiological, immunohistochemical methods and chromatomassspectrography. Enhanced activity of inducible NO-synthase, contamination of periulcer zone with microorganisms Klebsiella pneumoniae, Streptococcus beta-haemoliticus, enhancement of contents of catecholamines and serotonin in the blood serum were revealed. These changes are most expressed in severe blood loss, unstable local endoscopic hemostasis, high risk of a recurrent hemorrhage occurrence. The data obtained permit to prognosticate severity of a pathologic process course and to improve the treatment programe.
NASA Technical Reports Server (NTRS)
1974-01-01
The transient and steady state response of the respiratory control system for variations in volumetric fractions of inspired gases and special system parameters are modeled. The program contains the capability to change workload. The program is based on Grodins' respiratory control model and can be envisioned as a feedback control system comprised of a plant (the controlled system) and the regulating component (controlling system). The controlled system is partitioned into 3 compartments corresponding to lungs, brain, and tissue with a fluid interconnecting patch representing the blood.
Exponential error reduction in pretransfusion testing with automation.
South, Susan F; Casina, Tony S; Li, Lily
2012-08-01
Protecting the safety of blood transfusion is the top priority of transfusion service laboratories. Pretransfusion testing is a critical element of the entire transfusion process to enhance vein-to-vein safety. Human error associated with manual pretransfusion testing is a cause of transfusion-related mortality and morbidity and most human errors can be eliminated by automated systems. However, the uptake of automation in transfusion services has been slow and many transfusion service laboratories around the world still use manual blood group and antibody screen (G&S) methods. The goal of this study was to compare error potentials of commonly used manual (e.g., tiles and tubes) versus automated (e.g., ID-GelStation and AutoVue Innova) G&S methods. Routine G&S processes in seven transfusion service laboratories (four with manual and three with automated G&S methods) were analyzed using failure modes and effects analysis to evaluate the corresponding error potentials of each method. Manual methods contained a higher number of process steps ranging from 22 to 39, while automated G&S methods only contained six to eight steps. Corresponding to the number of the process steps that required human interactions, the risk priority number (RPN) of the manual methods ranged from 5304 to 10,976. In contrast, the RPN of the automated methods was between 129 and 436 and also demonstrated a 90% to 98% reduction of the defect opportunities in routine G&S testing. This study provided quantitative evidence on how automation could transform pretransfusion testing processes by dramatically reducing error potentials and thus would improve the safety of blood transfusion. © 2012 American Association of Blood Banks.
Neuroprotection and Blood-Brain Barrier Restoration by Salubrinal After a Cortical Stab Injury.
Barreda-Manso, M Asunción; Yanguas-Casás, Natalia; Nieto-Sampedro, Manuel; Romero-Ramírez, Lorenzo
2017-06-01
Following a central nervous system (CNS) injury, restoration of the blood-brain barrier (BBB) integrity is essential for recovering homeostasis. When this process is delayed or impeded, blood substances and cells enter the CNS parenchyma, initiating an additional inflammatory process that extends the initial injury and causes so-called secondary neuronal loss. Astrocytes and profibrotic mesenchymal cells react to the injury and migrate to the lesion site, creating a new glia limitans that restores the BBB. This process is beneficial for the resolution of the inflammation, neuronal survival, and the initiation of the healing process. Salubrinal is a small molecule with neuroprotective properties in different animal models of stroke and trauma to the CNS. Here, we show that salubrinal increased neuronal survival in the neighbourhood of a cerebral cortex stab injury. Moreover, salubrinal reduced cortical blood leakage into the parenchyma of injured animals compared with injured controls. Adjacent to the site of injury, salubrinal induced immunoreactivity for platelet-derived growth factor subunit B (PDGF-B), a specific mitogenic factor for mesenchymal cells. This effect might be responsible for the increased immunoreactivity for fibronectin and the decreased activation of microglia and macrophages in injured mice treated with salubrinal, compared with injured controls. The immunoreactivity for PDGF-B colocalized with neuronal nuclei (NeuN), suggesting that cortical neurons in the proximity of the injury were the main source of PDGF-B. Our results suggest that after an injury, neurons play an important role in both, the healing process and the restoration of the BBB integrity. J. Cell. Physiol. 232: 1501-1510, 2017. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.
Red blood cells as modulators of T cell growth and survival.
Arosa, Fernando A; Pereira, Carlos F; Fonseca, Ana M
2004-01-01
T cell homeostasis is largely controlled by a balance between cell death and survival and anomalies in either process account for a number of diseases linked to excessive or faulty T cell growth. Yet, the influence that cells outside the immunological system have on these processes has only recently received attention. Accumulated evidence indicate that homeostasis of the CD4+ and CD8+ T cell pools is highly dynamic and regulated by signals delivered by cells and molecules present in the different internal microenvironments. The major function of red blood cells (RBC) is generally considered to be oxygen and carbon dioxide transport. In recent years, however, RBC have been implicated in the regulation of basic physiological processes, from vascular contraction and platelet aggregation to T cell growth and survival. Regulation of T cell survival by RBC may influence the response of selected subsets of T cells to internal or external stimuli and may help explaining the immunomodulatory activities of red blood cells. By interfering in the balance between death and survival RBC become potential tools that can be manipulated to improve or reverse pathological situations characterized by anomalies in the control of T cell growth.
O'Dwyer, David N; Norman, Katy C; Xia, Meng; Huang, Yong; Gurczynski, Stephen J; Ashley, Shanna L; White, Eric S; Flaherty, Kevin R; Martinez, Fernando J; Murray, Susan; Noth, Imre; Arnold, Kelly B; Moore, Bethany B
2017-04-25
Idiopathic pulmonary fibrosis (IPF) is a progressive and fatal interstitial pneumonia. The disease pathophysiology is poorly understood and the etiology remains unclear. Recent advances have generated new therapies and improved knowledge of the natural history of IPF. These gains have been brokered by advances in technology and improved insight into the role of various genes in mediating disease, but gene expression and protein levels do not always correlate. Thus, in this paper we apply a novel large scale high throughput aptamer approach to identify more than 1100 proteins in the peripheral blood of well-characterized IPF patients and normal volunteers. We use systems biology approaches to identify a unique IPF proteome signature and give insight into biological processes driving IPF. We found IPF plasma to be altered and enriched for proteins involved in defense response, wound healing and protein phosphorylation when compared to normal human plasma. Analysis also revealed a minimal protein signature that differentiated IPF patients from normal controls, which may allow for accurate diagnosis of IPF based on easily-accessible peripheral blood. This report introduces large scale unbiased protein discovery analysis to IPF and describes distinct biological processes that further inform disease biology.
Bertolini, F; Battaglia, M; Zibera, C; Baroni, G; Soro, V; Perotti, C; Salvaneschi, L; Robustelli della Cuna, G
1996-10-01
We describe a new procedure for large-scale CB processing in the collection bag, thus minimizing the risk of CB contamination. A solution of 6% hydroxyethyl starch (HES) was added directly to the CB containing bag. After RBC sedimentation at 4 degrees C, the WBC-rich supernatant was collected in a satellite bag and centrifuged. After supernatant removal, the cell pellet was resuspended and the percent recovery of total WBC, CD34+ progenitor cells, CFU-GM and cobblestone area-forming cells (CAFC) evaluated. Results obtained with three different types of CB collection bags (300, 600 and 1000 ml) were analyzed and compared with those of an open system in 50 ml tubes. CB processing procedures in 300 and 1000 ml bags were associated with better WBC, CFU, CD34+ cell and CAFC recovery (83-93%). This novel CB processing procedure appears to be easy, effective and particularly suitable for large-scale banking under GMP conditions.
Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch.
Du, Yi-Chun; Lim, Bee-Yen; Ciou, Wei-Siang; Wu, Ming-Jui
2016-06-09
Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients.
Li, Siyang; Plouffe, Brian D.; Belov, Arseniy M.; Ray, Somak; Wang, Xianzhe; Murthy, Shashi K.; Karger, Barry L.; Ivanov, Alexander R.
2015-01-01
Isolation and molecular characterization of rare cells (e.g. circulating tumor and stem cells) within biological fluids and tissues has significant potential in clinical diagnostics and personalized medicine. The present work describes an integrated platform of sample procurement, preparation, and analysis for deep proteomic profiling of rare cells in blood. Microfluidic magnetophoretic isolation of target cells spiked into 1 ml of blood at the level of 1000–2000 cells/ml, followed by focused acoustics-assisted sample preparation has been coupled with one-dimensional PLOT-LC-MS methodology. The resulting zeptomole detection sensitivity enabled identification of ∼4000 proteins with injection of the equivalent of only 100–200 cells per analysis. The characterization of rare cells in limited volumes of physiological fluids is shown by the isolation and quantitative proteomic profiling of first MCF-7 cells spiked into whole blood as a model system and then two CD133+ endothelial progenitor and hematopoietic cells in whole blood from volunteers. PMID:25755294
[Ways to improve measurement accuracy of blood glucose sensing by mid-infrared spectroscopy].
Wang, Yan; Li, Ning; Xu, Kexin
2006-06-01
Mid-infrared (MIR) spectroscopy is applicable to blood glucose sensing without using any reagent, however, due to a result of inadequate accuracy, till now this method has not been used in clinical detection. The principle and key technologies of blood glucose sensing by MIR spectroscopy are presented in this paper. Along with our experimental results, the paper analyzes ways to enhance measurement accuracy and prediction accuracy by the following four methods: selection of optimized spectral region; application of spectra data processing method; elimination of the interference with other components in the blood, and promotion in system hardware. According to these four improving methods, we designed four experiments, i.e., strict determination of the region where glucose concentration changes most sensitively in MIR, application of genetic algorithm for wavelength selection, normalization of spectra for the purpose of enhancing measuring reproduction, and utilization of CO2 laser as light source. The results show that the measurement accuracy of blood glucose concentration is enhanced almost to a clinical detection level.
Li, Feng-Fei; Xie, Yun; Shi, Bing-Yin; Niu, Min; Guo, Hui; Cao, Yan; Liu, Bing-Li; Yan, Reng-Na; Su, Xiao-Fei; Wu, Jin-Dan; Zhang, Dan-Feng; Chen, Li-Ming; Ma, Jian-Hua
2018-06-01
The blood glucose point-of-care testing (POCT) system is important in the decision-making process involving patients suspected of having hypoglycemia. To investigate the real world of the POCT system being used in teaching hospitals in China. The survey was conducted by Hisend Research Group from May 2015 to July 2015 in four teaching hospitals in China. The survey questions were referred to the ISO 15197:2013 standard requirements for the use of the POCT system in a hospital setting. A total of 170 subjects were included from 4 hospitals, which included nursing staff, nurse unit managers, employees from the department of medical instruments, and staff members employed by the clinical laboratories in the Tianjin Metabolism Hospital, Nanjing First Hospital, First Affiliated Hospital of Dalian Medical University, and the First hospital affiliated with the Xi'an Transportation University. The average score for the four hospitals surveyed in this study was 66.6, which varied from 46.1 to 79.7. The main factors influencing the scores were the multiple choices of blood-glucose meters, and the quality control assessment. Our data indicates that the real world use of the POCT system in hospital settings in China needs more closer adherence to a quality management framework.
Song, Jie; Hu, Yajie; Hu, Yunguang; Wang, Jingjing; Zhang, Xiaolong; Wang, Lichun; Guo, Lei; Wang, Yancui; Ning, Ruotong; Liao, Yun; Zhang, Ying; Zheng, Huiwen; Shi, Haijing; He, Zhanlong; Li, Qihan; Liu, Longding
2016-03-02
Coxsackievirus A16 (CA16) is a dominant pathogen that results in hand, foot, and mouth disease and causes outbreaks worldwide, particularly in the Asia-Pacific region. However, the underlying molecular mechanisms remain unclear. Our previous study has demonstrated that the basic CA16 pathogenic process was successfully mimicked in rhesus monkey infant. The present study focused on the global gene expression changes in peripheral blood mononuclear cells of rhesus monkey infants with hand, foot, and mouth disease induced by CA16 infection at different time points. Genome-wide expression analysis was performed with Agilent whole-genome microarrays and established bioinformatics tools. Nine hundred and forty-eight significant differentially expressed genes that were associated with 5 gene ontology categories, including cell communication, cell cycle, immune system process, regulation of transcription and metabolic process were identified. Subsequently, the mapping of genes related to the immune system process by PANTHER pathway analysis revealed the predominance of inflammation mediated by chemokine and cytokine signaling pathways and the interleukin signaling pathway. Ultimately, co-expressed genes and their networks were analyzed. The results revealed the gene expression profile of the immune system in response to CA16 in rhesus monkey infants and suggested that such an immune response was generated as a result of the positive mobilization of the immune system. This initial microarray study will provide insights into the molecular mechanism of CA16 infection and will facilitate the identification of biomarkers for the evaluation of vaccines against this virus. Copyright © 2016 Elsevier B.V. All rights reserved.
Usuda, Takashi; Kobayashi, Naoki; Takeda, Sunao; Kotake, Yoshifumi
2010-01-01
We have developed the non-invasive blood pressure monitor which can measure the blood pressure quickly and robustly. This monitor combines two measurement mode: the linear inflation and the linear deflation. On the inflation mode, we realized a faster measurement with rapid inflation rate. On the deflation mode, we realized a robust noise reduction. When there is neither noise nor arrhythmia, the inflation mode incorporated on this monitor provides precise, quick and comfortable measurement. Once the inflation mode fails to calculate appropriate blood pressure due to body movement or arrhythmia, then the monitor switches automatically to the deflation mode and measure blood pressure by using digital signal processing as wavelet analysis, filter bank, filter combined with FFT and Inverse FFT. The inflation mode succeeded 2440 measurements out of 3099 measurements (79%) in an operating room and a rehabilitation room. The new designed blood pressure monitor provides the fastest measurement for patient with normal circulation and robust measurement for patients with body movement or severe arrhythmia. Also this fast measurement method provides comfortableness for patients.
An optical approach for non-invasive blood clot testing
NASA Astrophysics Data System (ADS)
Kalchenko, Vyacheslav; Brill, Alexander; Fine, Ilya; Harmelin, Alon
2007-02-01
Physiological blood coagulation is an essential biological process. Current tests for plasma coagulation (clotting) need to be performed ex vivo and require fresh blood sampling for every test. A recently published work describes a new, noninvasive, in vivo approach to assess blood coagulation status during mechanical occlusion1. For this purpose, we have tested this approach and applied a controlled laser beam to blood micro-vessels of the mouse ear during mechanical occlusion. Standard setup for intravital transillumination videomicroscopy and laser based imaging techniques were used for monitoring the blood clotting process. Temporal mechanical occlusion of blood vessels in the observed area was applied to ensure blood flow cessation. Subsequently, laser irradiation was used to induce vascular micro-injury. Changes in the vessel wall, as well as in the pattern of blood flow, predispose the area to vascular thrombosis, according to the paradigm of Virchow's triad. In our experiments, two elements of Virchow's triad were used to induce the process of clotting in vivo, and to assess it optically. We identified several parameters that can serve as markers of the blood clotting process in vivo. These include changes in light absorption in the area of illumination, as well as changes in the pattern of the red blood cells' micro-movement in the vessels where blood flow is completely arrested. Thus, our results indicate that blood coagulation status can be characterized by non-invasive, in vivo methodologies.
Jordan, A; Chen, D; Yi, Q-L; Kanias, T; Gladwin, M T; Acker, J P
2016-07-01
Quality control (QC) data collected by blood services are used to monitor production and to ensure compliance with regulatory standards. We demonstrate how analysis of quality control data can be used to highlight the sources of variability within red cell concentrates (RCCs). We merged Canadian Blood Services QC data with manufacturing and donor records for 28 227 RCC between June 2011 and October 2014. Units were categorized based on processing method, bag manufacturer, donor age and donor sex, then assessed based on product characteristics: haemolysis and haemoglobin levels, unit volume, leucocyte count and haematocrit. Buffy-coat method (top/bottom)-processed units exhibited lower haemolysis than units processed using the whole-blood filtration method (top/top). Units from female donors exhibited lower haemolysis than male donations. Processing method influenced unit volume and the ratio of additive solution to residual plasma. Stored red blood cell characteristics are influenced by prestorage processing and donor factors. Understanding the relationship between processing, donors and RCC quality will help blood services to ensure the safety of transfused products. © 2016 International Society of Blood Transfusion.
[The use of programmed microcalculators for automation of leukocyte count].
Plykin, D L
1989-01-01
Soviet programmed microcalculators are recommended to be used for the calculation of the leukocytic formulae when making serial blood analyses at clinical laboratories. The suggested program helps completely automate the process of estimating the leukocyte types, detectable in microscopic examination of the blood smears; the results may be obtained as a per cent ratio of the cells (a form most prevalent nowadays) and as their quantity per microliter of blood. The presence of service elements in the program essentially simplifies the work, making it convenient for an untrained user of the microcalculator. Since commercial Soviet programmed microcalculators somewhat differ in the systems of program steps, two variants of the program are suggested, adapted to the two most prevalent designs.
Urinary Biomarkers of Brain Diseases
An, Manxia; Gao, Youhe
2016-01-01
Biomarkers are the measurable changes associated with a physiological or pathophysiological process. Unlike blood, urine is not subject to homeostatic mechanisms. Therefore, greater fluctuations could occur in urine than in blood, better reflecting the changes in human body. The roadmap of urine biomarker era was proposed. Although urine analysis has been attempted for clinical diagnosis, and urine has been monitored during the progression of many diseases, particularly urinary system diseases, whether urine can reflect brain disease status remains uncertain. As some biomarkers of brain diseases can be detected in the body fluids such as cerebrospinal fluid and blood, there is a possibility that urine also contain biomarkers of brain diseases. This review summarizes the clues of brain diseases reflected in the urine proteome and metabolome. PMID:26751805
Serrano, Katherine; Levin, Elena; Culibrk, Brankica; Weiss, Sandra; Scammell, Ken; Boecker, Wolfgang F; Devine, Dana V
2010-01-01
BACKGROUND In high-volume processing environments, manual breakage of in-line closures can result in repetitive strain injury (RSI). Furthermore, these closures may be incorrectly opened causing shear-induced hemolysis. To overcome the variability of in-line closure use and minimize RSI, Fresenius Kabi developed a new in-line closure, the CompoFlow, with mechanical openers. STUDY DESIGN AND METHODS The consistency of the performance of the CompoFlow closure device was assessed, as was its effect on component quality. A total of 188 RBC units using CompoFlow blood bag systems and 43 using the standard bag systems were produced using the buffy coat manufacturing method. Twenty-six CompoFlow platelet (PLT) concentrates and 10 control concentrates were prepared from pools of four buffy coats. RBCs were assessed on Days 1, 21, and 42 for cellular variables and hemolysis. PLTs were assessed on Days 1, 3, and 7 for morphology, CD62P expression, glucose, lactate, and pH. A total of 308 closures were excised after processing and the apertures were measured using digital image analysis. RESULTS The use of the CompoFlow device significantly improved the mean extraction time with 0.46 ± 0.11 sec/mL for the CompoFlow units and 0.52 ± 0.13 sec/mL for the control units. The CompoFlow closures showed a highly reproducible aperture after opening (coefficient of variation, 15%) and the device always remained opened. PLT and RBC products showed acceptable storage variables with no differences between CompoFlow and control. CONCLUSIONS The CompoFlow closure devices improved the level of process control and processing time of blood component production with no negative effects on product quality. PMID:20529007
Mounts, W M; Liebman, M N
1997-07-01
We have developed a method for representing biological pathways and simulating their behavior based on the use of stochastic activity networks (SANs). SANs, an extension of the original Petri net, have been used traditionally to model flow systems including data-communications networks and manufacturing processes. We apply the methodology to the blood coagulation cascade, a biological flow system, and present the representation method as well as results of simulation studies based on published experimental data. In addition to describing the dynamic model, we also present the results of its utilization to perform simulations of clinical states including hemophilia's A and B as well as sensitivity analysis of individual factors and their impact on thrombin production.
Huang, Yan-Jang S; Lyons, Amy C; Hsu, Wei-Wen; Park, So Lee; Higgs, Stephen; Vanlandingham, Dana L
2017-01-01
Infection of mosquitoes is an essential step for the transmission of mosquito-borne arboviruses in nature. Engorgement of infectious blood meals from viremic infected vertebrate hosts allows the entry of viruses and initiates infection of midgut epithelial cells. Historically, the infection process of arboviruses in mosquitoes has been studied through the engorgement of mosquitoes from viremic laboratory animals or from artificial feeders containing blood mixed with viruses harvested from cell cultures. The latter approach using so-called artificial blood meals is more frequently used since it is readily optimized to maximize viral titer, negates the use of animals and can be used with viruses for which there are no small animal models. Use of artificial blood meals has enabled numerous studies on mosquito infections with a wide variety of viruses; however, as described here, with suitable modification it can also be used to study the interplay between infection, specific blood components, and physiological consequences associated with blood engorgement. For hematophagous female mosquitoes, blood is the primary nutritional source supporting all physiological process including egg development, and also influences neurological processes and behaviors such as host-seeking. Interactions between these blood-driven vector biological processes and arbovirus infection that is mediated via blood engorgement have not yet been specifically studied. This is in part because presentation of virus in whole blood inevitably induces enzymatic digestion processes, hormone driven oogenesis, and other biological changes. In this study, the infection process of Zika virus (ZIKV) in Aedes aegypti was characterized by oral exposure via viral suspension meals within minimally bovine serum albumin complemented medium or within whole blood. The use of bovine serum albumin in infectious meals provides an opportunity to evaluate the role of serum albumin during the process of flavivirus infection in mosquitoes. Infectious whole blood meals and infectious bovine serum albumin meals containing ZIKV were orally presented to two different groups of Ae. aegypti through membrane feeding. At 7 and 14 days post infection, infectious viruses were detected and viral dissemination from gut to other mosquito tissues was analyzed in orally challenged mosquitoes with 50% tissue culture infectious dose method on Vero76 cells. Zika virus infection was significantly impaired among mosquitoes orally challenged with infectious protein meals as compared to infectious whole blood meals. These results indicate the importance of the blood meal in the infection process of arboviruses in mosquitoes. It provides the basis for future studies to identify critical components in the blood of vertebrate hosts that facilitate arbovirus infection in mosquitoes.
Immunodeficiency and laser magnetic therapy in urology
NASA Astrophysics Data System (ADS)
Maati, Moufagued; Rozanov, Vladimir V.; Avdoshin, V. P.
1996-11-01
The importance of immunodeficiency problem has increased last time not only due to AIDS appearance, but also to a great extent as a result of the development and active practical use of the methods of immunology parameters investigations. Al great pharmaceutical firms are organizing the process of creating the drugs, influencing on the different phases of immunity, but unfortunately, the problem of their adverse effect and connected complications is till today a milestone. A great number of investigations, proving a good effect of laser-magnetic therapy concerning immune system have been done today. There is, in particular, changing of blood counts and immunologic tests after intravenous laser irradiation of blood. Intravenous laser irradiation of blood results in increasing of lymphocytes, T-immuno stimulation, stabilization of t-lymphocyte subpopulation, increasing of t-lymphocyte helper activity and decreasing of suppressor one.Under this laser action number of circulating immune complexes is decreased, and blood serum bactericide activity and lisozyme number are increased.
The Measurement of Ammonia in Human Breath and its Potential in Clinical Diagnostics.
Brannelly, N T; Hamilton-Shield, J P; Killard, A J
2016-11-01
Ammonia is an important component of metabolism and is involved in many physiological processes. During normal physiology, levels of blood ammonia are between 11 and 50 µM. Elevated blood ammonia levels are associated with a variety of pathological conditions such as liver and kidney dysfunction, Reye's syndrome and a variety of inborn errors of metabolism including urea cycle disorders (UCD), organic acidaemias and hyperinsulinism/hyperammonaemia syndrome in which ammonia may reach levels in excess of 1 mM. It is highly neurotoxic and so effective measurement is critical for assessing and monitoring disease severity and treatment. Ammonia is also a potential biomarker in exercise physiology and studies of drug metabolism. Current ammonia testing is based on blood sampling, which is inconvenient and can be subject to significant analytical errors due to the quality of the sample draw, its handling and preparation for analysis. Blood ammonia is in gaseous equilibrium with the lungs. Recent research has demonstrated the potential use of breath ammonia as a non-invasive means of measuring systemic ammonia. This requires measurement of ammonia in real breath samples with associated temperature, humidity and gas characteristics at concentrations between 50 and several thousand parts per billion. This review explores the diagnostic applications of ammonia measurement and the impact that the move from blood to breath analysis could have on how these processes and diseases are studied and managed.
Radin, Joanna
2014-09-01
In the decades after World War II, the World Health Organization (WHO) played an important role in managing the process of stabilizing collections of variable blood samples as a fundamentally unstable, protean, and unfolding biomedical resource. In this system, known and as yet unknown constituents of blood were positioned as relevant to the work of multiple constituencies including human population geneticists, physical anthropologists, and immunologists. To facilitate serving these and other constituencies, it was crucial to standardize practices of collecting and preserving samples of blood from globally distributed human populations. The WHO achieved this by linking its administrative infrastructure-comprised of expert advisory groups and technical reports-to key laboratories, which served as sites for demonstrating and also for disseminating standards for working with variable blood samples. The practices that were articulated in making blood samples into a flexible resource contributes to emerging histories of global health that highlight the centrality of new institutions, like the WHO, new forms of expertise, like population genetics and serological epidemiology, and new kinds of research materials, like frozen blood. Copyright © 2014 Elsevier Ltd. All rights reserved.
Red and infrared light distribution in blood
NASA Astrophysics Data System (ADS)
de Magalhães, Ana Carolina; Yoshimura, Elisabeth M.
2013-02-01
Low level laser therapy (LLLT) is used in several applications, including the reduction of inflammatory processes. It might be used to prevent the systemic inflammatory response syndrome (SIRS), which some patients develop after cardiopulmonary bypass (CPB) surgery. The objectives of this study were to investigate light distribution inside blood, in order to implement the LLLT during CPB, and, through this study, to determine the best wavelength and the best way to perform the treatment. The blood, diluted to the same conditions of CPB procedure was contained inside a cuvette and an optical fiber was used to collect the scattered light. Two wavelengths were used: 632.8 nm and 820 nm. Light distribution in blood inside CPB tubes was also evaluated. Compared to the 820 nm light, the 632.8 nm light is scattered further away from the laser beam, turning it possible that a bigger volume of blood be treated. The blood should be illuminated through the smallest diameter CPB tube, using at least four distinct points around it, in only one cross section, because the blood is kept passing through the tube all the time and the whole volume will be illuminated.
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
21 CFR 876.5820 - Hemodialysis system and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
.... (1) The extracorporeal blood system and accessories consists of tubing, pumps, pressure monitors, air... conditions and that consists of an extracorporeal blood system, a conventional dialyzer, a dialysate delivery system, and accessories. Blood from a patient flows through the tubing of the extracorporeal blood system...
Code of Federal Regulations, 2010 CFR
2010-04-01
... STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Red Blood Cells § 640.16 Processing. (a) Separation. Within the..., Red Blood Cells may be prepared either by centrifugation, done in a manner that will not tend to... sufficient to insure optimal cell preservation shall be left with the red cells except when a cryoprotective...
Pascutti, Maria Fernanda; Erkelens, Martje N.; Nolte, Martijn A.
2016-01-01
The ability of the bone marrow (BM) to generate copious amounts of blood cells required on a daily basis depends on a highly orchestrated process of proliferation and differentiation of hematopoietic stem and progenitor cells (HSPCs). This process can be rapidly adapted under stress conditions, such as infections, to meet the specific cellular needs of the immune response and the ensuing physiological changes. This requires a tight regulation in order to prevent either hematopoietic failure or transformation. Although adaptation to bacterial infections or systemic inflammation has been studied and reviewed in depth, specific alterations of hematopoiesis to viral infections have received less attention so far. Viruses constantly pose a significant health risk and demand an adequate, balanced response from our immune system, which also affects the BM. In fact, both the virus itself and the ensuing immune response can have a tremendous impact on the hematopoietic process. On one hand, this can be beneficial: it helps to boost the cellular response of the body to resolve the viral infection. But on the other hand, when the virus and the resulting antiviral response persist, the inflammatory feedback to the hematopoietic system will become chronic, which can be detrimental for a balanced BM output. Chronic viral infections frequently have clinical manifestations at the level of blood cell formation, and we summarize which viruses can lead to BM pathologies, like aplastic anemia, pancytopenia, hemophagocytic lymphohistiocytosis, lymphoproliferative disorders, and malignancies. Regarding the underlying mechanisms, we address specific effects of acute and chronic viral infections on blood cell production. As such, we distinguish four different levels in which this can occur: (1) direct viral infection of HSPCs, (2) viral recognition by HSPCs, (3) indirect effects on HSPCs by inflammatory mediators, and (4) the role of the BM microenvironment on hematopoiesis upon virus infection. In conclusion, this review provides a comprehensive overview on how viral infections can affect the formation of new blood cells, aiming to advance our understanding of the underlying cellular and molecular mechanisms to improve the treatment of BM failure in patients. PMID:27695457
Pascutti, Maria Fernanda; Erkelens, Martje N; Nolte, Martijn A
2016-01-01
The ability of the bone marrow (BM) to generate copious amounts of blood cells required on a daily basis depends on a highly orchestrated process of proliferation and differentiation of hematopoietic stem and progenitor cells (HSPCs). This process can be rapidly adapted under stress conditions, such as infections, to meet the specific cellular needs of the immune response and the ensuing physiological changes. This requires a tight regulation in order to prevent either hematopoietic failure or transformation. Although adaptation to bacterial infections or systemic inflammation has been studied and reviewed in depth, specific alterations of hematopoiesis to viral infections have received less attention so far. Viruses constantly pose a significant health risk and demand an adequate, balanced response from our immune system, which also affects the BM. In fact, both the virus itself and the ensuing immune response can have a tremendous impact on the hematopoietic process. On one hand, this can be beneficial: it helps to boost the cellular response of the body to resolve the viral infection. But on the other hand, when the virus and the resulting antiviral response persist, the inflammatory feedback to the hematopoietic system will become chronic, which can be detrimental for a balanced BM output. Chronic viral infections frequently have clinical manifestations at the level of blood cell formation, and we summarize which viruses can lead to BM pathologies, like aplastic anemia, pancytopenia, hemophagocytic lymphohistiocytosis, lymphoproliferative disorders, and malignancies. Regarding the underlying mechanisms, we address specific effects of acute and chronic viral infections on blood cell production. As such, we distinguish four different levels in which this can occur: (1) direct viral infection of HSPCs, (2) viral recognition by HSPCs, (3) indirect effects on HSPCs by inflammatory mediators, and (4) the role of the BM microenvironment on hematopoiesis upon virus infection. In conclusion, this review provides a comprehensive overview on how viral infections can affect the formation of new blood cells, aiming to advance our understanding of the underlying cellular and molecular mechanisms to improve the treatment of BM failure in patients.
Detection, manipulation and post processing of circulating tumor cells using optical techniques
NASA Astrophysics Data System (ADS)
Bakhtiaridoost, Somayyeh; Habibiyan, Hamidreza; Ghafoorifard, Hassan
2015-12-01
Circulating tumor cells (CTCs) are malignant cells that are derived from a solid tumor in the metastasis stage and are shed into the blood stream. These cells hold great promise to be used as liquid biopsy that is less aggressive than traditional biopsy. Recently, detection and enumeration of these cells has received ever-increasing attention from researchers as a way of early detection of cancer metastasis, determining the effectiveness of treatment and studying the mechanism of formation of secondary tumors. CTCs are found in blood at low concentration, which is a major limitation of isolation and detection of these cells. Over the last few years, multifarious research studies have been conducted on accurate isolation and detection and post processing of CTCs. Among all the proposed systems, microfluidic systems seem to be more attractive for researchers due to their numerous advantages. On the other hand, recent developments in optical methods have made the possibility of cellular studies at single-cell level. Thus, accuracy and efficiency of separation, detection and manipulation of CTCs can be improved using optical techniques. In this review, we describe optical methods that have been used for CTC detection, manipulation and post processing.
Cerebral venous circulatory system evaluation by ultrasonography.
Zavoreo, Iris; Basić-Kes, Vanja; Zadro-Matovina, Lucija; Lisak, Marijana; Corić, Lejla; Cvjeticanin, Timon; Ciliga, Dubravka; Bobić, Tatjana Trost
2013-06-01
Venous system can be classified as pulmonary veins, systemic veins and venous sinuses that are present only within the skull. Cerebral venous system is divided into two main parts, the superficial and the deep system. The main assignment of veins is to carry away deoxygenated blood and other maleficient materials from the tissues towards the heart. Veins have thinner walls and larger lumina than arteries. Between 60% and 70% of the total blood volume is found in veins. The major factors that influence venous function are the respiratory cycle, venous tone, the function of the right heart, gravity, and the muscle pump. Venous system, in general, can be presented by selective venography, Doppler sonography, computed tomography (CT) venography and magnetic resonance (MR) venography, and cerebral venous system can be displayed by selective venography, cerebral CT venography, cerebral MR venography, and specialized extracranial and transcranial Doppler sonography. The aim of this paper is to show the possibilities of intracranial and extracranial ultrasound evaluation of the head and neck venous circulation and chronic cerebrospinal venous insufficiency as one of the most common pathologies evaluated as part of neurodegenerative processes in the central nervous system.
Wang, Qiushi; Gao, Xinghua; Yuan, Zhe; Wang, Zhe; Meng, Yiming; Cao, Yan; Plotnikoff, Nicolas P; Griffin, Noreen; Shan, Fengping
2014-01-01
MENK, a penta-peptide is considered as being involved in the regulatory feedback loop between the immune and neuroendocrine systems, with marked modulation of various functions of human immune cells. The aim of the present work was to investigate change of lymphocyte subpopulations in peripheral blood of 50 cancer patients before and after treatment with MENK. Peripheral blood mononuclear cells (PBMCs) of peripheral blood from 50 cancer patients were isolated by density gradient centrifugation using Ficoll-Paque solution and cultured with MENK. We measured proliferation of total nucleated cells, subpopulations of individual CD4+T cells, CD8+T cells, CD4+CD25+ regulatory T cells (Treg), natural killer cells (NK) before and after treatment with 10-12M MENK in cell culture by flow cytometry (FCM). Our results indicated that MENK showed a strong inhibiting effect on Treg cells while it stimulated marked proliferation of other lymphocyte subpopulations. All data obtained were of significance statistically. It was therefore concluded that MENK could work as a strong immune booster with great potential in restoring damaged human immune system and we could consider MENK as a drug to treat cancer patients, whose immune systems are damaged by chemotherapy or radiotherapy. Furthermore we could consider MENK as a chemotherapy additive, which would sustain immune system of cancer patients during the process of chemotherapy to get maximized efficacy with minimized side effect. PMID:25424790
Banada, Padmapriya P; Deshpande, Srinidhi; Chakravorty, Soumitesh; Russo, Riccardo; Occi, James; Meister, Gabriel; Jones, Kelly J; Gelhaus, Carl H; Valderas, Michelle W; Jones, Martin; Connell, Nancy; Alland, David
2017-01-01
Francisella tularensis is a potential bioterrorism agent that is highly infectious at very low doses. Diagnosis of tularemia by blood culture and nucleic acid-based diagnostic tests is insufficiently sensitive. Here, we demonstrate a highly sensitive F. tularensis assay that incorporates sample processing and detection into a single cartridge suitable for point-of-care detection. The assay limit of detection (LOD) and dynamic range were determined in a filter-based cartridge run on the GeneXpert system. F. tularensis DNA in buffer or CFU of F. tularensis was spiked into human or macaque blood. To simulate detection in human disease, the assay was tested on blood drawn from macaques infected with F. tularensis Schu S4 at daily intervals. Assay detection was compared to that with a conventional quantitative PCR (qPCR) assay and blood culture. The assay LOD was 0.1 genome equivalents (GE) per reaction and 10 CFU/ml F. tularensis in both human and macaque blood. In infected macaques, the assay detected F. tularensis on days 1 to 4 postinfection in 21%, 17%, 60%, and 83% of macaques, respectively, compared to conventional qPCR positivity rates of 0%, 0%, 30%, and 100% and CFU detection of blood culture at 0%, 0%, 0%, and 10% positive, respectively. Assay specificity was 100%. The new cartridge-based assay can rapidly detect F. tularensis in bloodstream infections directly in whole blood at the early stages of infection with a sensitivity that is superior to that of other methods. The simplicity of the automated testing procedures may make this test suitable for rapid point-of-care detection. Copyright © 2016 American Society for Microbiology.
... After What Happens to Donated Blood First Time Blood Donors Hosting a Blood Drive Manage My Blood Drive ... some information about donating blood. Tip: Download the Blood Donor app . After your first donation, use the digital ...
Biofeedback-driven dialysis: where are we?
Santoro, Antonio; Ferramosca, Emiliana; Mancini, Elena
2008-01-01
The progressive increase in the mean age and the growing conditions of co-morbidity, especially of cardiovascular pathologies and diabetes, have significantly worsened the patients' clinical status and tolerance to the hemodialysis (HD) treatment. On the other hand, the demand for short treatment times enhances the risk for hemodynamic instability as well as for inadequate depuration. The traditional management of the dialysis session, setting of predefined treatment parameters, with active therapeutic interventions only in the event of complications, is definitely unsuitable for short-lasting treatments, often complicated by hemodynamic instability, especially in critical patients. The first step to improve the management of the dialysis session is the utilization of continuous and uninvasive monitoring systems for hemodynamic or biochemical parameters involved in the dialysis quality. Special sensors for the continuous measurement of blood volume, blood temperature, blood pressure, heart rate, electrolytes, have been realized throughout the last 10 years. As a second step, some of these devices have been implemented in the dialysis instrumentation, mainly with a view to preventing cardiocirculatory instability but also to control the dialysis efficiency (biofeedback control systems). The basic components of a biofeedback system are: the plant, the sensors, the actuators and the controller. The plant is the biological process that we need to control, while the sensors are the devices used for measuring the output variables. The actuators are the working arms of the controller. The controller is the mathematical model that continuously sets the measured output variable against the reference input and modifies the actuators in order to reduce any discrepancies. Yet, in practice there are a number of conceptual, physical and technological difficulties to be overcome. In particular, the behavior of what is to be controlled may be non-linear and time-varying, with interactions between the actuators and the controlled variable. In these cases, more sophisticated control systems are needed, which must be capable of identifying the behavior of the process, and continuously update information data while the control is on. These complex systems are called adaptive controllers. In dialysis, over the last few years, it has been relatively easy to realize some biofeedback systems since a series of sensors have been developed for online monitoring. Three biofeedback devices are routinely used with the aim of improving the cardiovascular instability, one of the main problems limiting the tolerance to treatment by the patient and the quality of HD in itself - the first is the biofeedback control of blood volume, the second is the biofeedback control of thermal balance, and the third is the biofeedback control of blood pressure.
Yousefi, Siavash; Qin, Jia; Dziennis, Suzan; Wang, Ruikang K.
2014-01-01
Abstract. Cutaneous wound healing consists of multiple overlapping phases starting with blood coagulation following incision of blood vessels. We utilized label-free optical coherence tomography and optical microangiography (OMAG) to noninvasively monitor healing process and dynamics of microcirculation system in a mouse ear pinna wound model. Mouse ear pinna is composed of two layers of skin separated by a layer of cartilage and because its total thickness is around 500 μm, it can be utilized as an ideal model for optical imaging techniques. These skin layers are identical to human skin structure except for sweat ducts and glands. Microcirculatory system responds to the wound injury by recruiting collateral vessels to supply blood flow to hypoxic region. During the inflammatory phase, lymphatic vessels play an important role in the immune response of the tissue and clearing waste from interstitial fluid. In the final phase of wound healing, tissue maturation, and remodeling, the wound area is fully closed while blood vessels mature to support the tissue cells. We show that using OMAG technology allows noninvasive and label-free monitoring and imaging each phase of wound healing that can be used to replace invasive tissue sample histology and immunochemistry technologies. PMID:25036212
Kato, Hirotomo; Jochim, Ryan C.; Gomez, Eduardo A.; Sakoda, Ryo; Iwata, Hiroyuki; Valenzuela, Jesus G.; Hashiguchi, Yoshihisa
2010-01-01
Triatoma (T.) dimidiata is a hematophagous Hemiptera and a main vector of Chagas disease. The saliva of this and other blood-sucking insects contains potent pharmacologically active components that assist them in counteracting the host hemostatic and inflammatory systems during blood feeding. To describe the repertoire of potential bioactive salivary molecules from this insect, a number of randomly selected transcripts from the salivary gland cDNA library of T. dimidiata were sequenced and analyzed. This analysis showed that 77.5% of the isolated transcripts coded for putative secreted proteins, and 89.9% of these coded for variants of the lipocalin family proteins. The most abundant transcript was a homologue of procalin, the major allergen of T. protracta saliva, and contributed more than 50% of the transcripts coding for putative secreted proteins, suggesting that it may play an important role in the blood-feeding process. Other salivary transcripts encoding lipocalin family proteins had homology to triabin (a thrombin inhibitor), triafestin (an inhibitor of kallikrein–kinin system), pallidipin (an inhibitor of collagen-induced platelet aggregation) and others with unknown function. PMID:19900580
Stokes, Elizabeth A; Wordsworth, Sarah; Staves, Julie; Mundy, Nicola; Skelly, Jane; Radford, Kelly; Stanworth, Simon J
2018-04-01
In an environment of limited health care resources, it is crucial for health care systems which provide blood transfusion to have accurate and comprehensive information on the costs of transfusion, incorporating not only the costs of blood products, but also their administration. Unfortunately, in many countries accurate costs for administering blood are not available. Our study aimed to generate comprehensive estimates of the costs of administering transfusions for the UK National Health Service. A detailed microcosting study was used to cost two key inputs into transfusion: transfusion laboratory and nursing inputs. For each input, data collection forms were developed to capture staff time, equipment, and consumables associated with each step in the transfusion process. Costing results were combined with costs of blood product wastage to calculate the cost per unit transfused, separately for different blood products. Data were collected in 2014/15 British pounds and converted to US dollars. A total of 438 data collection forms were completed by 74 staff. The cost of administering blood was $71 (£49) per unit for red blood cells, $84 (£58) for platelets, $55 (£38) for fresh-frozen plasma, and $72 (£49) for cryoprecipitate. Blood administration costs add substantially to the costs of the blood products themselves. These are frequently incurred costs; applying estimates to the blood components supplied to UK hospitals in 2015, the annual cost of blood administration, excluding blood products, exceeds $175 (£120) million. These results provide more accurate estimates of the total costs of transfusion than those previously available. © 2018 AABB.
Blood donors' motivation and attitude to non-remunerated blood donation in Lithuania
Buciuniene, Ilona; Stonienë, Laimutë; Blazeviciene, Aurelija; Kazlauskaite, Ruta; Skudiene, Vida
2006-01-01
Background In the Soviet period, the blood donation system operated in Lithuania exclusively on a remunerative basis. After joining the EU, Lithuania committed itself to meeting the EU requirements to provide all consumers within its boundaries with safe blood products made from voluntary unpaid blood donations. However, the introduction of a non-remunerated donation system may considerably affect donors' motivation and retention. Thus the aim of the current research was to determine blood donation motives among the present donors and investigate their attitude towards non-remunerated donation. Methods A questionnaire survey of 400 blood donors. Survey data processed using SPSS statistical analysis package. Statistical data reliability checked using Fisher's exact test (p < 0.05). Results Paid donors comprised 89.9%, while non-paid ones made 10.1% of the respondents. Research findings show that 93 per cent of the paid donors give blood on a regular basis; while among the non-remunerated donors the same figure amounted merely to 20.6 per cent. The idea of the remuneration necessity is supported by 78.3 per cent of the paid donors, while 64.7 per cent of the non-remunerated respondents believe that remuneration is not necessary. The absolute majority of the paid donors (92%) think they should be offered a monetary compensation for blood donation, while more than half of the non-remunerated donors (55.9) claim they would be content with a mere appreciation of the act. Provided no remuneration were offered, 28.44 per cent of the respondents would carry on doing it, 29.6 per cent would do it only in emergency, 29.6 per cent would donate blood merely for their family or friends, and 12.3 per cent would quit it completely. Conclusion Most respondents admitted having donated blood for the following reasons: willingness to help the ill or monetary compensation. Majority would consent to free blood donation only in case of emergency or as a family replacement, which leads to a conclusion that provided monetary remuneration is completely terminated part of the currently active paid donors would withdraw from this activity, which might seriously affect the national supply of blood and its products. PMID:16792814
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stenina, M.A.; Potapova, A.A.; Biryukov, A.V.
1987-01-01
The authors study the state of immunoregulatory process in patients with systemic lupus erythematosus at the T-T-cell interaction level and seek to test the possibility of the pharmacological modulation of this process. The proliferative activity of mononuclear lymphocytes, extracted from the blood of ten lupus patients, was assessed by measuring the incorporation of tritiated thymidine into cultures stimulated by phytohemagglutinin, concanavalin, and theophylline. The comparative effects of each of these agents on the immunoregulatory and proliferative activity of the lymphocytes are reported.
Hosokawa, Masahito; Asami, Marie; Yoshino, Tomoko; Tsujimura, Noriyuki; Takahashi, Masayuki; Nakasono, Satoshi; Tanaka, Tsuyoshi; Matsunaga, Tadashi
2013-02-15
Monitoring of hematotoxicity, which requires serial blood collection, is difficult to carry out in small animals due to a lack of non-invasive, individual animal-appropriate techniques that enable enumeration of leukocyte subsets from limited amounts of whole blood. In this study, a microfluidic device equipped with a microcavity array that enables highly efficient separation of leukocytes from submicroliters of whole blood was applied for hematotoxicity monitoring in mice. The microcavity array can specifically separate leukocytes from whole blood based on differences in the size and deformability between leukocytes and other blood cells. Mouse leukocytes recovered on aligned microcavities were continuously processed for image-based immunophenotypic analysis. Our device successfully recovered almost 100% of mouse leukocytes in 0.1 μL of whole blood without the effect of serial blood collection such as changes in body weight and total leukocyte count. We assessed benzene-associated hematotoxicity in mice using this system. Mice were administered with benzene once daily and the depression of leukocyte numbers induced in individual mice was successfully monitored from tail vein blood collected every other day for 2 weeks. Serial monitoring of the leukocyte number in individual mice will contribute to the understanding of hematotoxicity and reduction of the number of animal experiment trials. Copyright © 2012 Elsevier B.V. All rights reserved.
Sersa, I; Vidmar, J; Grobelnik, B; Mikac, U; Tratar, G; Blinc, A
2007-06-07
Axially directed blood plasma flow can significantly accelerate thrombolysis of non-occlusive blood clots. Viscous forces caused by shearing of blood play an essential role in this process, in addition to biochemical fibrinolytic reactions. An analytical mathematical model based on the hypothesis that clot dissolution dynamics is proportional to the power of the flowing blood plasma dissipated along the clot is presented. The model assumes cylindrical non-occlusive blood clots with the flow channel in the centre, in which the flow is assumed to be laminar and flow rate constant at all times during dissolution. Effects of sudden constriction on the flow and its impact on the dissolution rate are also considered. The model was verified experimentally by dynamic magnetic resonance (MR) microscopy of artificial blood clots dissolving in an in vitro circulation system, containing plasma with a magnetic resonance imaging contrast agent and recombinant tissue-type plasminogen activator (rt-PA). Sequences of dynamically acquired 3D low resolution MR images of entire clots and 2D high resolution MR images of clots in the axial cross-section were used to evaluate the dissolution model by fitting it to the experimental data. The experimental data fitted well to the model and confirmed our hypothesis.
1992-03-12
Contributes to many transport and regulatory processes and has multifunctional binding properties which range form various metals, to fatty acids, hormones, and a wide spectrum of therapeutic drugs. The most abundant protein of the circulatory system. It binds and transports an incredible variety of biological and pharmaceutical ligands throughout the blood stream. Principal Investigator was Larry DeLucas.
Emotional Processing in High-Functioning Autism--Physiological Reactivity and Affective Report
ERIC Educational Resources Information Center
Bolte, Sven; Feineis-Matthews, Sabine; Poustka, Fritz
2008-01-01
This study examined physiological response and affective report in 10 adult individuals with autism and 10 typically developing controls. An emotion induction paradigm using stimuli from the International Affective Picture System was applied. Blood pressure, heart and self-ratings of experienced valence (pleasure), arousal and dominance (control)…
Microfluidic Blood Cell Preparation: Now and Beyond
Yu, Zeta Tak For; Yong, Koh Meng Aw; Fu, Jianping
2014-01-01
Blood plays an important role in homeostatic regulation with each of its cellular components having important therapeutic and diagnostic uses. Therefore, separation and sorting of blood cells has been of a great interest to clinicians and researchers. However, while conventional methods of processing blood have been successful in generating relatively pure fractions, they are time consuming, labor intensive, and are not optimal for processing small volume blood samples. In recent years, microfluidics has garnered great interest from clinicians and researchers as a powerful technology for separating blood into different cell fractions. As microfluidics involves fluid manipulation at the microscale level, it has the potential for achieving high-resolution separation and sorting of blood cells down to a single-cell level, with an added benefit of integrating physical and biological methods for blood cell separation and analysis on the same single chip platform. This paper will first review the conventional methods of processing and sorting blood cells, followed by a discussion on how microfluidics is emerging as an efficient tool to rapidly change the field of blood cell sorting for blood-based therapeutic and diagnostic applications. PMID:24515899
Chudziak, Jakub; Burt, Deborah J; Mohan, Sumitra; Rothwell, Dominic G; Mesquita, Bárbara; Antonello, Jenny; Dalby, Suzanne; Ayub, Mahmood; Priest, Lynsey; Carter, Louise; Krebs, Matthew G; Blackhall, Fiona; Dive, Caroline; Brady, Ged
2016-01-21
Circulating tumour cells (CTCs) have potential utility as minimally-invasive biomarkers to aid cancer treatment decision making. However, many current CTC technologies enrich CTCs using specific surface epitopes that do not necessarily reflect CTC heterogeneity. Here we evaluated the epitope-independent Parsortix system which enriches CTCs based on size and rigidity using both healthy normal volunteer blood samples spiked with tumour cells and blood samples from patients with small cell lung cancer (SCLC). Blood samples were maintained unfractionated at room temperature for up to 4 days followed by plasma removal for circulating free DNA (cfDNA) isolation and direct application of the remaining cell component to the Parsortix system. For tumour cells expressing the EpCAM cell surface marker the numbers of spiked cells retained using the Parsortix system and by EpCAM-positive selection using CellSearch® were not significantly different, whereas only the Parsortix system showed strong enrichment of cells with undetectable EpCAM expression. In a pilot clinical study we banked both enriched CTCs as well as plasma from SCLC patient blood samples. Upon retrieval of the banked Parsortix cellular samples we could detect cytokeratin positive CTCs in all 12 SCLC patients tested. Interestingly, processing parallel samples from the same patients by EpCAM enrichment using CellSearch® revealed only 83% (10/12) with cytokeratin positive CTCs indicating the Parsortix system is enriching for EpCAM negative SCLC CTCs. Our combined results indicate the Parsortix system is a valuable tool for combined cfDNA isolation and CTC enrichment that enables CTC analysis to be extended beyond dependence on surface epitopes.
Assessment of anaerobic blood cultures in pediatric oncology patients.
Monsonís Cabedo, Manuel; Rives Solá, Susana; Noguera-Julian, Antoni; Urrea Ayala, Mireia; Cruz Martinez, Ofelia; Gené Giralt, Amadeu
2017-01-01
The routine use of a single aerobic bottle for blood culture in pediatric patients has become commonplace, as anaerobic bacteria are not frequently involved in clinically significant infections. The aim of this study was to assess the usefulness of routinely performing anaerobic blood cultures in pediatric oncology patients. Prospective study was conducted on pediatric (<18 years) patients affected with febrile syndrome after receiving chemotherapy for hematological or solid malignancies. Samples were inoculated into pediatric aerobic and standard anaerobic bottles (BacT/Alert automatic system). Strains were considered clinically significant, or deemed as contaminants, depending on isolation circumstances and clinical criteria. A total of 876 blood cultures from 228 patients were processed during the 21-month study period (January 2014 to September 2015). Baseline diagnosis included 143 solid tumors and 67/18 cases of leukemia/lymphoma. Bacterial growth was detected in 90 (10.2%) blood cultures for 95 different isolates, of which 62 (7.1%)/63 isolates were considered clinically significant. Among the latter, 38 (60.3%) microorganisms grew in both aerobic and anaerobic bottles, 18 (28.6%) only in aerobic bottles, and 7 (11.1%) only in anaerobic bottles. Gram-negative bacilli (33; 52.4%), mainly from the Enterobacteriaceae family, were the most frequently isolated microorganisms. Overall, only 3 out of 90 isolates (3.3%) were strict anaerobes (Propionibacterium acnes), and all of them were deemed contaminants. Strict anaerobes did not cause significant infections in febrile pediatric oncology patients, and anaerobic blood culture bottles offered no additional advantages over aerobic media. Our results suggest that routine blood cultures should be solely processed in aerobic media in this group of patients. Copyright © 2016 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.
Nie, Liju; Li, Fulai; Huang, Xiaolin; Aguilar, Zoraida P; Wang, Yongqiang Andrew; Xiong, Yonghua; Fu, Fen; Xu, Hengyi
2018-04-25
Studies regarding circulating tumor cells (CTCs) have great significance for cancer prognosis, treatment monitoring, and metastasis diagnosis. However, due to their extremely low concentration in peripheral blood, isolation and enrichment of CTCs are the key steps for early detection. To this end, targeting the folic acid receptors (FRs) on the CTC surface for capture with folic acid (FA) using bovine serum albumin (BSA)-tether for multibiotin enhancement in combination with streptavidin-coated magnetic nanoparticles (MNPs-SA) was developed for ovarian cancer CTC isolation. The streptavidin-biotin-system-mediated two-step binding strategy was shown to capture CTCs from whole blood efficiently without the need for a pretreatment process. The optimized parameters for this system exhibited an average capture efficiency of 80%, which was 25% higher than that of FA-decorated magnetic nanoparticles based on the one-step CTC separation method. Moreover, the isolated cells remained highly viable and were cultured directly without detachment from the MNPs-SA-biotin-CTC complex. Furthermore, when the system was applied for the isolation and detection of CTCs in ovarian cancer patients' peripheral blood samples, it exhibited an 80% correlation with clinical diagnostic criteria. The results indicated that FA targeting, in combination with BSA-based multibiotin enhancement magnetic nanoparticle separation, is a promising tool for CTC enrichment and detection of early-stage ovarian cancer.
Current concepts in blood glucose monitoring
Khadilkar, Kranti Shreesh; Bandgar, Tushar; Shivane, Vyankatesh; Lila, Anurag; Shah, Nalini
2013-01-01
Blood glucose monitoring has evolved over the last century. The concept of adequate glycemic control and minimum glycemic variability requires an ideal, accurate and reliable glucose monitoring system. The search for an ideal blood glucose monitoring system still continues. This review explains the various blood glucose monitoring systems with special focus on the monitoring systems like self- monitored blood glucose (SMBG) and continuous glucose monitoring system (CGMS). It also focuses on the newer concepts of blood glucose monitoring and their incorporation in routine clinical management of diabetes mellitus. PMID:24910827
Leptin and the central nervous system control of glucose metabolism.
Morton, Gregory J; Schwartz, Michael W
2011-04-01
The regulation of body fat stores and blood glucose levels is critical for survival. This review highlights growing evidence that leptin action in the central nervous system plays a key role in both processes. Investigation into underlying mechanisms has begun to clarify the physiological role of leptin in the control of glucose metabolism and raises interesting new possibilities for the treatment of diabetes and related disorders.
Yatim, Karim M; Gosto, Minja; Humar, Rishab; Williams, Amanda L; Oberbarnscheidt, Martin H
2016-10-01
Bony fish are among the first vertebrates to possess an innate and adaptive immune system. In these species, the kidney has a dual function: filtering solutes similar to mammals and acting as a lymphoid organ responsible for hematopoiesis and antigen processing. Recent studies have shown that the mammalian kidney has an extensive network of mononuclear phagocytes, whose function is not fully understood. Here, we employed two-photon intravital microscopy of fluorescent reporter mice to demonstrate that renal dendritic cells encase the microvasculature in the cortex, extend dendrites into the peritubular capillaries, and sample the blood for antigen. We utilized a mouse model of systemic bacterial infection as well as immune complexes to demonstrate antigen uptake by renal dendritic cells. As a consequence, renal dendritic cells mediated T-cell migration into the kidney in an antigen-dependent manner in the setting of bacterial infection. Thus, renal dendritic cells may be uniquely positioned to play an important role not only in surveillance of systemic infection but also in local infection and autoimmunity. Copyright © 2016 International Society of Nephrology. Published by Elsevier Inc. All rights reserved.
Discovering objects in a blood recipient information system.
Qiu, D; Junghans, G; Marquardt, K; Kroll, H; Mueller-Eckhardt, C; Dudeck, J
1995-01-01
Application of object-oriented (OO) methodologies has been generally considered as a solution to the problem of improving the software development process and managing the so-called software crisis. Among them, object-oriented analysis (OOA) is the most essential and is a vital prerequisite for the successful use of other OO methodologies. Though there are already a good deal of OOA methods published, the most important aspect common to all these methods: discovering objects classes truly relevant to the given problem domain, has remained a subject to be intensively researched. In this paper, using the successful development of a blood recipient information system as an example, we present our approach which is based on the conceptual framework of responsibility-driven OOA. In the discussion, we also suggest that it may be inadequate to simply attribute the software crisis to the waterfall model of the software development life-cycle. We are convinced that the real causes for the failure of some software and information systems should be sought in the methodologies used in some crucial phases of the software development process. Furthermore, a software system can also fail if object classes essential to the problem domain are not discovered, implemented and visualized, so that the real-world situation cannot be faithfully traced by it.
A RAPID Method for Blood Processing to Increase the Yield of Plasma Peptide Levels in Human Blood.
Teuffel, Pauline; Goebel-Stengel, Miriam; Hofmann, Tobias; Prinz, Philip; Scharner, Sophie; Körner, Jan L; Grötzinger, Carsten; Rose, Matthias; Klapp, Burghard F; Stengel, Andreas
2016-04-28
Research in the field of food intake regulation is gaining importance. This often includes the measurement of peptides regulating food intake. For the correct determination of a peptide's concentration, it should be stable during blood processing. However, this is not the case for several peptides which are quickly degraded by endogenous peptidases. Recently, we developed a blood processing method employing Reduced temperatures, Acidification, Protease inhibition, Isotopic exogenous controls and Dilution (RAPID) for the use in rats. Here, we have established this technique for the use in humans and investigated recovery, molecular form and circulating concentration of food intake regulatory hormones. The RAPID method significantly improved the recovery for (125)I-labeled somatostatin-28 (+39%), glucagon-like peptide-1 (+35%), acyl ghrelin and glucagon (+32%), insulin and kisspeptin (+29%), nesfatin-1 (+28%), leptin (+21%) and peptide YY3-36 (+19%) compared to standard processing (EDTA blood on ice, p <0.001). High performance liquid chromatography showed the elution of endogenous acyl ghrelin at the expected position after RAPID processing, while after standard processing 62% of acyl ghrelin were degraded resulting in an earlier peak likely representing desacyl ghrelin. After RAPID processing the acyl/desacyl ghrelin ratio in blood of normal weight subjects was 1:3 compared to 1:23 following standard processing (p = 0.03). Also endogenous kisspeptin levels were higher after RAPID compared to standard processing (+99%, p = 0.02). The RAPID blood processing method can be used in humans, yields higher peptide levels and allows for assessment of the correct molecular form.
Rabe, Fran; Kadidlo, Diane; Van Orsow, Lisa; McKenna, David
2013-10-01
Qualification of a cord blood bank (CBB) is a complex process that includes evaluation of multiple aspects of donor screening and testing, processing, accreditation and approval by professional cell therapy groups, and results of received cord blood units. The University of Minnesota Medical Center Cell Therapy Laboratory has established a CBB vendor qualification process to ensure the CBB meets established regulatory and quality requirements. The deployed qualification of CBBs is based on retrospective and prospective review of the CBB. Forty-one CBBs were evaluated retrospectively: seven CBBs were disqualified based on failed quality control (QC) results. Eight CBBs did not meet the criteria for retrospective qualification because fewer than 3 cord blood units were received and the CBB was not accredited. As of March 2012, three US and one non-US CBBs have been qualified prospectively. One CBB withdrew from the qualification process after successful completion of the comprehensive survey and subsequent failure of the provided QC unit to pass the minimum criteria. One CBB failed the prospective qualification process based on processing methods that were revealed during the paper portion of the evaluation. A CBB qualification process is necessary for a transplant center to manage the qualification of the large number of CBBs needed to support a umbilical cord blood transplantation program. A transplant center that has utilized cord blood for a number of years before implementation of a qualification process should use a retrospective qualification process along with a prospective process. © 2013 American Association of Blood Banks.
Chorioallantoic placentation in Galea spixii (Rodentia, Caviomorpha, Caviidae)
Oliveira, Moacir F; Mess, Andrea; Ambrósio, Carlos E; Dantas, Carlos AG; Favaron, Phelipe O; Miglino, Maria A
2008-01-01
Background Placentas of guinea pig-related rodents are appropriate animal models for human placentation because of their striking similarities to those of humans. To optimize the pool of potential models in this context, it is essential to identify the occurrence of characters in close relatives. Methods In this study we first analyzed chorioallantoic placentation in the prea, Galea spixii, as one of the guinea pig's closest relatives. Material was collected from a breeding group at the University of Mossoró, Brazil, including 18 individuals covering an ontogenetic sequence from initial pregnancy to term. Placentas were investigated by means of histology, electron microscopy, immunohistochemistry (vimentin, α-smooth muscle actin, cytokeration) and proliferation activity (PCNA). Results Placentation in Galea is primarily characterized by an apparent regionalization into labyrinth, trophospongium and subplacenta. It also has associated growing processes with clusters of proliferating trophoblast cells at the placental margin, internally directed projections and a second centre of proliferation in the labyrinth. Finally, the subplacenta, which is temporarily supplied in parallel by the maternal and fetal blood systems, served as the center of origin for trophoblast invasion. Conclusion Placentation in Galea reveals major parallels to the guinea pig and other caviomorphs with respect to the regionalization of the placenta, the associated growing processes, as well as trophoblast invasion. A principal difference compared to the guinea pig occurred in the blood supply of the subplacenta. Characteristics of the invasion and expanding processes indicate that Galea may serve as an additional animal model that is much smaller than the guinea pig and where the subplacenta partly has access to both maternal and fetal blood systems. PMID:18771596
Pipatpanukul, Chinnawut; Takeya, Sasaki; Baba, Akira; Amarit, Ratthasart; Somboonkaew, Armote; Sutapun, Boonsong; Kitpoka, Pimpun; Kunakorn, Mongkol; Srikhirin, Toemsak
2018-04-15
The application of Surface Plasmon Resonance Imaging (SPRi) for the detection of transmembrane antigen of the Rhesus (Rh) blood group system is demonstrated. Clinically significant Rh blood group system antigens, including D, C, E, c, and e, can be simultaneously identified via solid phase immobilization assay, which offers significant time savings and assay simplification. Red blood cells (RBCs) flowed through the micro-channel, where a suitable condition for Rh blood group detection was an RBC dilution of 1:10 with a stop-flow condition. Stop flow showed an improvement in specific binding compared to continuous flow. Rh antigens required a longer incubation time to react with the immobilized antibody than A and B antigens due to the difference in antigen type and their location on the RBC. The interaction between the immobilized antibodies and their specific antigenic counterpart on the RBC showed a significant difference in RBC removal behavior using shear flow, measured from the decay of the SPR signal. The strength of the interaction between the immobilized antibody and RBC antigen was determined from the minimum wall shear stress required to start the decay process in the SPR signal. For a given range of immobilized antibody surface densities, the Rh antigen possesses a stronger interaction than A, B, and AB antigens. Identification of 82 samples of ABO and Rh blood groups using SPRi showed good agreement with the standard micro-column agglutination technique. A wider coverage of antigenic recognition for RBC when using the solid phase immobilization assay was demonstrated for the RBC with the antigenic site located on the transmembrane protein of the clinically significant Rh antigen. Given the level of accuracy and precision, the technique showed potential for the detection of the Rh minor blood group system. Copyright © 2017 Elsevier B.V. All rights reserved.
Engle, Martha; Ferguson, Allison; Fields, Willa
2016-01-01
The purpose of this quality improvement project was to redesign a hospital meal delivery process in order to shorten the time between blood glucose monitoring and corresponding insulin administration and improve glycemic control. This process change redesigned the workflow of the dietary and nursing departments. Modifications included nursing, rather than dietary, delivering meal trays to patients receiving insulin. Dietary marked the appropriate meal trays and phoned each unit prior to arrival on the unit. The process change was trialed on 2 acute care units prior to implementation hospital wide. Elapsed time between blood glucose monitoring and insulin administration was analyzed before and after process change as well as evaluation of glucometrics: percentage of patients with blood glucose between 70 and 180 mg/dL (percent perfect), blood glucose greater than 300 mg/dL (extreme hyperglycemia), and blood glucose less than 70 mg/dL (hypoglycemia). Percent perfect glucose results improved from 45% to 53%, extreme hyperglycemia (blood glucose >300 mg/dL) fell from 11.7% to 5%. Hypoglycemia demonstrated a downward trend line, demonstrating that with improving glycemic control hypoglycemia rates did not increase. Percentage of patients receiving meal insulin within 30 minutes of blood glucose check increased from 35% to 73%. In the hospital, numerous obstacles were present that interfered with on-time meal insulin delivery. Establishing a meal delivery process with the nurse performing the premeal blood glucose check, delivering the meal, and administering the insulin improves overall blood glucose control. Nurse-led process improvement of blood glucose monitoring, meal tray delivery, and insulin administration does lead to improved glycemic control for the inpatient population.
Dalla-Costa, Libera M; Morello, Luis G; Conte, Danieli; Pereira, Luciane A; Palmeiro, Jussara K; Ambrosio, Altair; Cardozo, Dayane; Krieger, Marco A; Raboni, Sonia M
2017-09-01
Sepsis is the leading cause of death in intensive care units (ICUs) worldwide and its diagnosis remains a challenge. Blood culturing is the gold standard technique for blood stream infection (BSI) identification. Molecular tests to detect pathogens in whole blood enable early use of antimicrobials and affect clinical outcomes. Here, using real-time PCR, we evaluated DNA extraction using seven manual and three automated commercially available systems with whole blood samples artificially contaminated with Escherichia coli, Staphylococcus aureus, and Candida albicans, microorganisms commonly associated with BSI. Overall, the commercial kits evaluated presented several technical limitations including long turnaround time and low DNA yield and purity. The performance of the kits was comparable for detection of high microorganism loads (10 6 CFU/mL). However, the detection of lower concentrations was variable, despite the addition of pre-processing treatment to kits without such steps. Of the evaluated kits, the UMD-Universal CE IVD kit generated a higher quantity of DNA with greater nucleic acid purity and afforded the detection of the lowest microbial load in the samples. The inclusion of pre-processing steps with the kit seems to be critical for the detection of microorganism DNA directly from whole blood. In conclusion, future application of molecular techniques will require overcoming major challenges such as the detection of low levels of microorganism nucleic acids amidst the large quantity of human DNA present in samples or differences in the cellular structures of etiological agents that can also prevent high-quality DNA yields. Copyright © 2017 Elsevier B.V. All rights reserved.
Marinova, Mariela; Artusi, Carlo; Brugnolo, Laura; Antonelli, Giorgia; Zaninotto, Martina; Plebani, Mario
2013-11-01
Although, due to its high specificity and sensitivity, LC-MS/MS is an efficient technique for the routine determination of immunosuppressants in whole blood, it involves time-consuming manual sample preparation. The aim of the present study was therefore to develop an automated sample-preparation protocol for the quantification of sirolimus, everolimus and tacrolimus by LC-MS/MS using a liquid handling platform. Six-level commercially available blood calibrators were used for assay development, while four quality control materials and three blood samples from patients under immunosuppressant treatment were employed for the evaluation of imprecision. Barcode reading, sample re-suspension, transfer of whole blood samples into 96-well plates, addition of internal standard solution, mixing, and protein precipitation were performed with a liquid handling platform. After plate filtration, the deproteinised supernatants were submitted for SPE on-line. The only manual steps in the entire process were de-capping of the tubes, and transfer of the well plates to the HPLC autosampler. Calibration curves were linear throughout the selected ranges. The imprecision and accuracy data for all analytes were highly satisfactory. The agreement between the results obtained with manual and those obtained with automated sample preparation was optimal (n=390, r=0.96). In daily routine (100 patient samples) the typical overall total turnaround time was less than 6h. Our findings indicate that the proposed analytical system is suitable for routine analysis, since it is straightforward and precise. Furthermore, it incurs less manual workload and less risk of error in the quantification of whole blood immunosuppressant concentrations than conventional methods. © 2013.
A multi-level model accounting for the effects of JAK2-STAT5 signal modulation in erythropoiesis.
Lai, Xin; Nikolov, Svetoslav; Wolkenhauer, Olaf; Vera, Julio
2009-08-01
We develop a multi-level model, using ordinary differential equations, based on quantitative experimental data, accounting for murine erythropoiesis. At the sub-cellular level, the model includes a description of the regulation of red blood cell differentiation through Epo-stimulated JAK2-STAT5 signalling activation, while at the cell population level the model describes the dynamics of (STAT5-mediated) red blood cell differentiation from their progenitors. Furthermore, the model includes equations depicting the hypoxia-mediated regulation of hormone erythropoietin blood levels. Take all together, the model constitutes a multi-level, feedback loop-regulated biological system, involving processes in different organs and at different organisational levels. We use our model to investigate the effect of deregulation in the proteins involved in the JAK2-STAT5 signalling pathway in red blood cells. Our analysis results suggest that down-regulation in any of the three signalling system components affects the hematocrit level in an individual considerably. In addition, our analysis predicts that exogenous Epo injection (an already existing treatment for several blood diseases) may compensate the effects of single down-regulation of Epo hormone level, STAT5 or EpoR/JAK2 expression level, and that it may be insufficient to counterpart a combined down-regulation of all the elements in the JAK2-STAT5 signalling cascade.
Automated blood-sample handling in the clinical laboratory.
Godolphin, W; Bodtker, K; Uyeno, D; Goh, L O
1990-09-01
The only significant advances in blood-taking in 25 years have been the disposable needle and evacuated blood-drawing tube. With the exception of a few isolated barcode experiments, most sample-tracking is performed through handwritten or computer-printed labels. Attempts to reduce the hazards of centrifugation have resulted in air-tight lids or chambers, the use of which is time-consuming and cumbersome. Most commonly used clinical analyzers require serum or plasma, distributed into specialized containers, unique to that analyzer. Aliquots for different tests are prepared by handpouring or pipetting. Moderate to large clinical laboratories perform so many different tests that even multi-analyzers performing multiple analyses on a single sample may account for only a portion of all tests ordered for a patient. Thus several aliquots of each specimen are usually required. We have developed a proprietary serial centrifuge and blood-collection tube suitable for incorporation into an automated or robotic sample-handling system. The system we propose is (a) safe--avoids or prevents biological danger to the many "handlers" of blood; (b) small--minimizes the amount of sample taken and space required to adapt to the needs of satellite and mobile testing, and direct interfacing with analyzers; (c) serial--permits each sample to be treated according to its own "merits," optimizes throughput, and facilitates flexible automation; and (d) smart--ensures quality results through monitoring and intelligent control of patient identification, sample characteristics, and separation process.
Phase synchronization of oscillations in cardiovascular and respiratory systems in humans
NASA Astrophysics Data System (ADS)
Tankanag, Arina V.; Grinevich, Andrey A.; Tikhonova, Irina V.; Chaplygina, Alina V.; Chemeris, Nikolay K.
2017-04-01
Phase synchronization between blood flow oscillations of left and right forearm skin sites, heart rate variability (HRV) and breath rate were studied from healthy volunteers at rest. The degree of synchronization between the phases of the analyzed signals was estimated from the value of the wavelet phase coherence. High medians of values of phase wavelet coherence function were obtained for the endothelial, neurogenic, myogenic and cardiac intervals. Significant phase synchronization were demonstrated between HRV and skin blood flow oscillations in both left and right forearms in a wide frequency range from 0.04 to 0.4 Hz. Six participants exhibited low phase synchronization (< 0.5) between the breath rate and HRV, while nine participants had high phase synchronization (> 0.5). This distribution was not affected by the sex or sympathovagal status of volunteers. Participants with low phase synchronization between breath rate and HRV featured low phase synchronization (< 0.5) between breath rate and blood flow oscillations in both forearms. Contrariwise, in subjects with high phase synchronization between respiratory rhythm and HRV both low and high phase synchronization between breath rate and blood flow oscillations in both forearms was observed. The results obtained allow us to suggest that the organism possesses a mechanism mediating the synchronization of blood flow oscillations in the skin microvasculature with all other periodical processes across the cardiovascular system, in particular, with HRV and breath rate over a wide frequency range.
Nitric oxide in red blood cell adaptation to hypoxia.
Zhao, Yajin; Wang, Xiang; Noviana, Milody; Hou, Man
2018-06-01
Nitric oxide (NO) appears to be involved in virtually every aspect of cardiovascular biology. Most attention has been focused on the role of endothelial-derived NO in basal blood flow regulation by relaxing vascular smooth muscle; however, it is now known that NO derived from red blood cells (RBCs) plays a fundamental role in vascular homeostasis by enhancing oxygen (O2) release at the cellular and physiological level. Hypoxia is an often seen problem in diverse conditions; systemic adaptations to hypoxia permit people to adjust to the hypoxic environment at high altitudes and to disease processes. In addition to the cardiopulmonary and hematologic adaptations that support systemic O2 delivery in hypoxia, RBCs assist through newly described NO-based mechanisms, in line with their vital role in O2 transport and delivery. Furthermore, to increase the local blood flow in proportion to metabolic demand, NO regulates membrane mechanical properties thereby modulating RBC deformability and O2 carrying-releasing function. In this review article, we focus on the effect of NO bioactivity on RBC-based mechanisms that regulate blood flow and RBC deformability. RBC adaptations to hypoxia are summarized, with particular attention to NO-dependent S-nitrosylation of membrane proteins and hemoglobin (S-nitrosohemoglobin). The NO/S-nitrosylation/RBC vasoregulatory cascade contributes fundamentally to the molecular understanding of the role of NO in human adaptation to hypoxia and may inform novel therapeutic strategies.
Vaquier, C; Legrand, D; Caldani, C
2009-05-01
Since 1985, a Council Resolution defines a new approach to technical harmonization and standards. The directives resulting from this new approach establish the essential safety requirements with which products put on the market must conform, and which should therefore enjoy free movement throughout the European Union, owing to a presumption of conformity. However, if the manufacturer is responsible for the conformity of its product in terms of safety, it is the end-user who must make sure that its requirements for a specific use or a considered application are satisfied and that the product meets its needs. It is the objective of the procedure of validation, which calls upon protocols of qualification intended to show the aptitude of a material, a system, a device, of an installation, to meet the requirements of specified quality and safety. This concept of qualification applies to the data-processing software of the hospital blood banks. Only the stage of operational qualification will be developed here. It involves scenarios made up of test files which make it possible to check the electronic data interchanges between the hospital blood bank and the blood establishment (transmission of the results of analysis, transmission of the data of traceability), as well as the functions of assistance to the issuing of the labile blood products.
Blood banking and transfusion medicine for the apheresis medicine practitioner.
Jeffus, Susanne; Wehrli, Gay
2012-01-01
This article provides a concise overview of blood banking and transfusion medicine (BBTM) for the therapeutic apheresis medicine practitioner. It addresses the complete pathway from blood donor qualification to blood collection, to processing and storing blood components, to patient testing, to ordering blood components for therapeutic apheresis (TA) procedures, to preparing the component for transfusion, and finally to transfusion. The nurses, technologists, and physicians orchestrate these activities in concert to best serve patients undergoing TA procedures. Enhancing knowledge of these processes may improve the quality of patient care and the utilization of blood products. Copyright © 2012 Wiley Periodicals, Inc.
Nabeel, P M; Karthik, Srinivasa; Joseph, Jayaraj; Sivaprakasam, Mohanasankar
2017-07-01
We present a prototype design of dual element photoplethysmograph (PPG) probe along with associated measurement system for carotid local pulse wave velocity (PWV) evaluation in a non-invasive and continuous manner. The PPG probe consists of two identical sensing modules placed 23 mm apart. Simultaneously measured blood pulse waveforms from these arterial sites were processed and the pulse transit time delay was resolved using the developed application-specific software. The ability of developed PPG probe and associated measurement system to detect acute changes in carotid local PWV due to blood pressure (BP) variations was experimentally validated by an in-vivo study. Intra-subject carotid BP elevation was achieved by an upper arm cuff based occlusion, which offered a controlled way of local PWV escalation. The elevated carotid BP values were also recorded by a calibrated pressure tonometer prior to the study, and was used as a reference. A significant increment (1.0 - 2.6 m/s) in local PWV was observed and was proportional to the BP increment induced by the occlusive reactive hyperemia. Study results demonstrated the feasibility of real-time signal acquisition and reliable local PWV evaluation under normal and elevated BP conditions using the developed measurement system.
Detection of Hypertension Retinopathy Using Deep Learning and Boltzmann Machines
NASA Astrophysics Data System (ADS)
Triwijoyo, B. K.; Pradipto, Y. D.
2017-01-01
hypertensive retinopathy (HR) in the retina of the eye is disturbance caused by high blood pressure disease, where there is a systemic change of arterial in the blood vessels of the retina. Most heart attacks occur in patients caused by high blood pressure symptoms of undiagnosed. Hypertensive retinopathy Symptoms such as arteriolar narrowing, retinal haemorrhage and cotton wool spots. Based on this reasons, the early diagnosis of the symptoms of hypertensive retinopathy is very urgent to aim the prevention and treatment more accurate. This research aims to develop a system for early detection of hypertension retinopathy stage. The proposed method is to determine the combined features artery and vein diameter ratio (AVR) as well as changes position with Optic Disk (OD) in retinal images to review the classification of hypertensive retinopathy using Deep Neural Networks (DNN) and Boltzmann Machines approach. We choose this approach of because based on previous research DNN models were more accurate in the image pattern recognition, whereas Boltzmann machines selected because It requires speedy iteration in the process of learning neural network. The expected results from this research are designed a prototype system early detection of hypertensive retinopathy stage and analysed the effectiveness and accuracy of the proposed methods.
Fast targeted analysis of 132 acidic and neutral drugs and poisons in whole blood using LC-MS/MS.
Di Rago, Matthew; Saar, Eva; Rodda, Luke N; Turfus, Sophie; Kotsos, Alex; Gerostamoulos, Dimitri; Drummer, Olaf H
2014-10-01
The aim of this study was to develop an LC-MS/MS based screening technique that covers a broad range of acidic and neutral drugs and poisons by combining a small sample volume and efficient extraction technique with simple automated data processing. After protein precipitation of 100μL of whole blood, 132 common acidic and neutral drugs and poisons including non-steroidal anti-inflammatory drugs, barbiturates, anticonvulsants, antidiabetics, muscle relaxants, diuretics and superwarfarin rodenticides (47 quantitated, 85 reported as detected) were separated using a Shimadzu Prominence HPLC system with a C18 separation column (Kinetex XB-C18, 4.6mm×150mm, 5μm), using gradient elution with a mobile phase of 25mM ammonium acetate buffer (pH 7.5)/acetonitrile. The drugs were detected using an ABSciex(®) API 2000 LC-MS/MS system (ESI+ and -, MRM mode, two transitions per analyte). The method was fully validated in accordance with international guidelines. Quantification data obtained using one-point calibration compared favorably to that using multiple calibrants. The presented LC-MS/MS assay has proven to be applicable for determination of the analytes in blood. The fast and reliable extraction method combined with automated processing gives the opportunity for high throughput and fast turnaround times for forensic and clinical toxicology. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Effects of Simulated Heat Waves with Strong Sudden Cooling Weather on ApoE Knockout Mice
Zhang, Shuyu; Kuang, Zhengzhong; Zhang, Xiakun
2015-01-01
This study analyzes the mechanism of influence of heat waves with strong sudden cooling on cardiovascular diseases (CVD) in ApoE−/− mice. The process of heat waves with strong sudden cooling was simulated with a TEM1880 meteorological-environment simulation chamber according to the data obtained at 5 a.m. of 19 June 2006 to 11 p.m. of 22 June 2006. Forty-eight ApoE−/− mice were divided into six blocks based on their weight. Two mice from each block were randomly assigned to control, heat wave, temperature drop, and rewarming temperature groups. The experimental groups were transferred into the climate simulator chamber for exposure to the simulated heat wave process with strong sudden temperature drop. After 55, 59, and 75 h of exposure, the experimental groups were successively removed from the chamber to monitor physiological indicators. Blood samples were collected by decollation, and the hearts were harvested in all groups. The levels of heat stress factors (HSP60, SOD, TNF, sICAM-1, HIF-1α), cold stress factors (NE, EPI), vasoconstrictor factors (ANGII, ET-1, NO), and four items of blood lipid (TC, TG, HDL-C, and LDL-C) were measured in each ApoE−/− mouse. Results showed that the heat waves increased the levels of heat stress factors except SOD decreased, and decreased the levels of vasoconstrictor factors and blood lipid factors except TC increased. The strong sudden temperature drop in the heat wave process increased the levels of cold stress factors, vasoconstrictor factors and four blood lipid items (except the level of HDL-C which decreased) and decreased the levels of heat stress factors (except the level of SOD which increased). The analysis showed that heat waves could enhance atherosclerosis of ApoE−/− mice. The strong sudden temperature drop during the heat wave process increased the plasma concentrations of NE and ANGII, which indicates SNS activation, and resulted in increased blood pressure. NE and ANGII are vasoconstrictors involved in systemic vasoconstriction especially in the superficial areas of the body and conducive to increased blood pressure. The increase in the blood lipid levels of TG, LDL-C, TC, and LDL-C/HDL-C further aggravated CVD. This paper explored the influence mechanism of the heat waves with sudden cooling on CVD in ApoE−/− mice. PMID:26016434
Effects of Simulated Heat Waves with Strong Sudden Cooling Weather on ApoE Knockout Mice.
Zhang, Shuyu; Kuang, Zhengzhong; Zhang, Xiakun
2015-05-26
This study analyzes the mechanism of influence of heat waves with strong sudden cooling on cardiovascular diseases (CVD) in ApoE-/- mice. The process of heat waves with strong sudden cooling was simulated with a TEM1880 meteorological-environment simulation chamber according to the data obtained at 5 a.m. of 19 June 2006 to 11 p.m. of 22 June 2006. Forty-eight ApoE-/- mice were divided into six blocks based on their weight. Two mice from each block were randomly assigned to control, heat wave, temperature drop, and rewarming temperature groups. The experimental groups were transferred into the climate simulator chamber for exposure to the simulated heat wave process with strong sudden temperature drop. After 55, 59, and 75 h of exposure, the experimental groups were successively removed from the chamber to monitor physiological indicators. Blood samples were collected by decollation, and the hearts were harvested in all groups. The levels of heat stress factors (HSP60, SOD, TNF, sICAM-1, HIF-1α), cold stress factors (NE, EPI), vasoconstrictor factors (ANGII, ET-1, NO), and four items of blood lipid (TC, TG, HDL-C, and LDL-C) were measured in each ApoE-/- mouse. Results showed that the heat waves increased the levels of heat stress factors except SOD decreased, and decreased the levels of vasoconstrictor factors and blood lipid factors except TC increased. The strong sudden temperature drop in the heat wave process increased the levels of cold stress factors, vasoconstrictor factors and four blood lipid items (except the level of HDL-C which decreased) and decreased the levels of heat stress factors (except the level of SOD which increased). The analysis showed that heat waves could enhance atherosclerosis of ApoE-/- mice. The strong sudden temperature drop during the heat wave process increased the plasma concentrations of NE and ANGII, which indicates SNS activation, and resulted in increased blood pressure. NE and ANGII are vasoconstrictors involved in systemic vasoconstriction especially in the superficial areas of the body and conducive to increased blood pressure. The increase in the blood lipid levels of TG, LDL-C, TC, and LDL-C/HDL-C further aggravated CVD. This paper explored the influence mechanism of the heat waves with sudden cooling on CVD in ApoE-/- mice.
Sub-micro-liter Electrochemical Single-Nucleotide-Polymorphism Detector for Lab-on-a-Chip System
NASA Astrophysics Data System (ADS)
Tanaka, Hiroyuki; Fiorini, Paolo; Peeters, Sara; Majeed, Bivragh; Sterken, Tom; de Beeck, Maaike Op; Hayashi, Miho; Yaku, Hidenobu; Yamashita, Ichiro
2012-04-01
A sub-micro-liter single-nucleotide-polymorphism (SNP) detector for lab-on-a-chip applications is developed. This detector enables a fast, sensitive, and selective SNP detection directly from human blood. The detector is fabricated on a Si substrate by a standard complementary metal oxide semiconductor/micro electro mechanical systems (CMOS/MEMS) process and Polydimethylsiloxane (PDMS) molding. Stable and reproducible measurements are obtained by implementing an on-chip Ag/AgCl electrode and encapsulating the detector. The detector senses the presence of SNPs by measuring the concentration of pyrophosphoric acid generated during selective DNA amplification. A 0.5-µL-volume detector enabled the successful performance of the typing of a SNP within the ABO gene using human blood. The measured sensitivity is 566 pA/µM.
Advances of blood cell-based drug delivery systems.
Sun, Yanan; Su, Jing; Liu, Geyi; Chen, Jianjun; Zhang, Xiumei; Zhang, Ran; Jiang, Minhan; Qiu, Mingfeng
2017-01-01
Blood cells, including erythrocytes, leukocytes and platelets are used as drug carriers in a wide range of applications. They have many unique advantages such as long life-span in circulation (especially erythrocytes), target release capacities (especially platelets), and natural adhesive properties (leukocytes and platelets). These properties make blood cell based delivery systems, as well as their membrane-derived carriers, far superior to other drug delivery systems. Despite the advantages, the further development of blood cell-based delivery systems was hindered by limitations in the source, storage, and mass production. To overcome these problems, synthetic biomaterials that mimic blood cell and nanocrystallization of blood cells have been developed and may represent the future direction for blood cell membrane-based delivery systems. In this paper, we review recent progress of the rising blood cell-based drug delivery systems, and also discuss their challenges and future tendency of development. Copyright © 2016. Published by Elsevier B.V.
Zhao, Bo; Kokoza, Vladimir A.; Saha, Tusar T.; Wang, Stephanie; Roy, Sourav; Raikhel, Alexander S.
2015-01-01
Pathogen transmission by mosquitoes is tightly linked to blood feeding which, in turn, is required for egg development. Studies of these processes would greatly benefit from genetic methods, such as the binary Gal4/UAS system. The latter has been well established for model organisms, but its availability is limited for mosquitoes. The objective of this study was to develop the blood-meal-activated, gut-specific Gal4/UAS system for the yellow-fever mosquito Aedes aegypti and utilize it to investigate the regulation of gut-specific gene expression. A 1.1-kb, 5' upstream region of the carboxypeptidase A (CP) gene was used to genetically engineer the CP-Gal4 driver mosquito line. The CP-Gal4 specifically activated the Enhanced Green Fluorescent Protein (EGFP) reporter only after blood feeding in the gut of the CP-Gal4>UAS-EGFP female Ae. aegypti. We used this system to study the regulation of CP gene expression. In vitro treatments with either amino acids (AAs) or insulin stimulated expression of the CP-Gal4>UAS-EGFP transgene; no effect was observed with 20-hydroxyecdysone (20E) treatments. The transgene activation by AAs and insulin was blocked by rapamycin, the inhibitor of the Target-of-Rapamycin kinase (TOR). RNA interference (RNAi) silence of the insulin receptor (IR) reduced the expression of the CP-Gal4>UAS-EGFP transgene. Thus, in vitro and in vivo experiments have revealed that insulin and TOR pathways control expression of the digestive enzyme CP. In contrast, 20E, the major regulator of post-blood-meal vitellogenic events in female mosquitoes, has no role in regulating the expression of this gene. This novel CP-Gal4/UAS system permits functional testing of midgut-specific genes that are involved in blood digestion and interaction with pathogens in Ae. aegypti mosquitoes. PMID:25152428
[Conceptual self-management analysis of hypertensive individuals].
Balduino, Anice de Fátima Ahmad; Mantovani, Maria de Fátima; Lacerda, Maria Ribeiro; Meier, Marineli Joaquim
2013-12-01
This research aimed to analyze the concept of self-management of hypertensive individuals. Theoretical and documentary study based on Walker and Avant's conceptual analysis by means of the Scientific Electronic Library Brazil and the Medical Literature Analysis and Retrieval System Online in the Coordination for Higher Education Personnel Development (CAPES, in Portuguese) and the National Library of Medicine websites. Fourteen (14) articles and one (1) thesis were selected and reviewed in Portuguese and English, in the period January 2007 to September 2012. missing doctor's appointments, non-compliance to blood pressure control treatment to recommendations to proper diet standards and stress. Attributer blood pressure control and disease management Consequences home monitoring of blood pressure with control improvement, accomplishment of disease management, compliance and sharing of the creation process of self-management goals and caring activities by the interdiscplinary team through individualized actions. It was concluded that the self-management concept is a dynamic, active process which requires knowledge, attitude, discipline, determination, commitment self-regulation, empowerment and self-efficiency in order to manage the disease and achieve healthy living.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-26
...; (Formerly FDA-2007D-0393)] Guidance for Industry: Blood Establishment Computer System Validation in the User... Industry: Blood Establishment Computer System Validation in the User's Facility'' dated April 2013. The... document entitled ``Guidance for Industry: Blood Establishment Computer System Validation in the User's...
Minimizing camera-eye optical aberrations during the 3D reconstruction of retinal structures
NASA Astrophysics Data System (ADS)
Aldana-Iuit, Javier; Martinez-Perez, M. Elena; Espinosa-Romero, Arturo; Diaz-Uribe, Rufino
2010-05-01
3D reconstruction of blood vessels is a powerful visualization tool for physicians, since it allows them to refer to qualitative representation of their subject of study. In this paper we propose a 3D reconstruction method of retinal vessels from fundus images. The reconstruction method propose herein uses images of the same retinal structure in epipolar geometry. Images are preprocessed by RISA system for segmenting blood vessels and obtaining feature points for correspondences. The correspondence points process is solved using correlation. The LMedS analysis and Graph Transformation Matching algorithm are used for outliers suppression. Camera projection matrices are computed with the normalized eight point algorithm. Finally, we retrieve 3D position of the retinal tree points by linear triangulation. In order to increase the power of visualization, 3D tree skeletons are represented by surfaces via generalized cylinders whose radius correspond to morphological measurements obtained by RISA. In this paper the complete calibration process including the fundus camera and the optical properties of the eye, the so called camera-eye system is proposed. On one hand, the internal parameters of the fundus camera are obtained by classical algorithms using a reference pattern. On the other hand, we minimize the undesirable efects of the aberrations induced by the eyeball optical system assuming that contact enlarging lens corrects astigmatism, spherical and coma aberrations are reduced changing the aperture size and eye refractive errors are suppressed adjusting camera focus during image acquisition. Evaluation of two self-calibration proposals and results of 3D blood vessel surface reconstruction are presented.
Bedside arterial blood gas monitoring system using fluorescent optical sensors
NASA Astrophysics Data System (ADS)
Bartnik, Daniel J.; Rymut, Russell A.
1995-05-01
We describe a bedside arterial blood gas (ABG) monitoring system which uses fluorescent optical sensors in the measurement of blood pH, PCO2 and PO2. The Point-of-Care Arterial Blood Gas Monitoring System consists of the SensiCathTM optical sensor unit manufactured by Optical Sensors Incorporated and the TramTM Critical Care Monitoring System with ABG Module manufactured by Marquette Electronics Incorporated. Current blood gas measurement techniques require a blood sample to be removed from the patient and transported to an electrochemical analyzer for analysis. The ABG system does not require removal of blood from the patient or transport of the sample. The sensor is added to the patient's existing arterial line. ABG measurements are made by drawing a small blood sample from the arterial line in sufficient quantity to ensure an undiluted sample at the sensor. Measurements of pH, PCO2 and PO2 are made within 60 seconds. The blood is then returned to the patient, the line flushed and results appear on the bedside monitor. The ABG system offers several advantages over traditional electrochemical analyzers. Since the arterial line remains closed during the blood sampling procedure the patient's risk of infection is reduced and the caregiver's exposure to blood is eliminated. The single-use, disposable sensor can be measure 100 blood samples over 72 hours after a single two-point calibration. Quality Assurance checks are also available and provide the caregiver the ability to assess system performance even after the sensor is patient attached. The ABG module integrates with an existing bedside monitoring system. This allows ABG results to appear on the same display as ECG, respiration, blood pressure, cardiac output, SpO2, and other clinical information. The small module takes up little space in the crowded intensive care unit. Performance studies compare the ABG system with an electrochemical blood gas analyzer. Study results demonstrated accurate and precise blood gas measurement of 100 samples and 72 hour performance without need for re-calibration.
Liu, Mengmeng; Cheng, Xinran; Li, Kaikai; Xu, Mingrui; Wu, Yongji; Wang, Mengli; Zhang, Qianru; Yan, Wenyong; Luo, Chang; Zhao, Shanting
2018-05-25
Stem cell research has become a frontier in the field of life sciences, and provides an ideal model for exploring developmental biology problems such as embryogenesis, histiocytosis, and gene expression regulation, as well as opens up new doors for clinical tissue defective and inheritance diseases. Among them, menstrual blood-derived stem cells (MenSCs) are characterized by wide source, multi-directional differentiation potential, low immune rejection characteristics. Thus, MenSCs can achieve individual treatment and have the most advantage of the clinical application. The central nervous system, including brain and spinal cord, is susceptible to injury. And lethality and morbidity of them tops the list of all types of trauma. Compared to peripheral nervous system, recovery of central nervous system after damage remains extremely hard. However, the treatment of stem cells, especially MenSCs, is expected to solve this problem. Therefore, biological characteristics of MenSCs and their treatment in the respect of central nervous system diseases have been reviewed at home and abroad in recent years, so as to provide reference for the treatment of central nervous system diseases.
Fetal-Maternal Interactions in the Synepitheliochorial Placenta Using the eGFP Cloned Cattle Model
Mess, Andrea; Perecin, Felipe; Bressan, Fabiana Fernandes; Mesquita, Ligia Garcia; Miglino, Maria Angelica; Pimentel, José RodrigoValim; Neto, Paulo Fantinato; Meirelles, Flávio Vieira
2013-01-01
Background To investigate mechanisms of fetal-maternal cell interactions in the bovine placenta, we developed a model of transgenic enhanced Green Fluorescent Protein (t-eGFP) expressing bovine embryos produced by nuclear transfer (NT) to assess the distribution of fetal-derived products in the bovine placenta. In addition, we searched for male specific DNA in the blood of females carrying in vitro produced male embryos. Our hypothesis is that the bovine placenta is more permeable to fetal-derived products than described elsewhere. Methodology/Principal Findings Samples of placentomes, chorion, endometrium, maternal peripheral blood leukocytes and blood plasma were collected during early gestation and processed for nested-PCR for eGFP and testis-specific Y-encoded protein (TSPY), western blotting and immunohistochemistry for eGFP detection, as well as transmission electron microscopy to verify the level of interaction between maternal and fetal cells. TSPY and eGFP DNA were present in the blood of cows carrying male pregnancies at day 60 of pregnancy. Protein and mRNA of eGFP were observed in the trophoblast and uterine tissues. In the placentomes, the protein expression was weak in the syncytial regions, but intense in neighboring cells on both sides of the fetal-maternal interface. Ultrastructurally, our samples from t-eGFP expressing NT pregnancies showed to be normal, such as the presence of interdigitating structures between fetal and maternal cells. In addition, channels-like structures were present in the trophoblast cells. Conclusions/Significance Data suggested that there is a delivery of fetal contents to the maternal system on both systemic and local levels that involved nuclear acids and proteins. It not clear the mechanisms involved in the transfer of fetal-derived molecules to the maternal system. This delivery may occur through nonclassical protein secretion; throughout transtrophoblastic-like channels and/or by apoptotic processes previously described. In conclusion, the bovine synepitheliochorial placenta displays an intimate fetal-maternal interaction, similar to other placental types for instance human and mouse. PMID:23724045
Fetal-maternal interactions in the synepitheliochorial placenta using the eGFP cloned cattle model.
Pereira, Flavia Thomaz Verechia; Oliveira, Lilian J; Barreto, Rodrigo da Silva Nunes; Mess, Andrea; Perecin, Felipe; Bressan, Fabiana Fernandes; Mesquita, Ligia Garcia; Miglino, Maria Angelica; Pimentel, José RodrigoValim; Fantinato Neto, Paulo; Meirelles, Flávio Vieira
2013-01-01
To investigate mechanisms of fetal-maternal cell interactions in the bovine placenta, we developed a model of transgenic enhanced Green Fluorescent Protein (t-eGFP) expressing bovine embryos produced by nuclear transfer (NT) to assess the distribution of fetal-derived products in the bovine placenta. In addition, we searched for male specific DNA in the blood of females carrying in vitro produced male embryos. Our hypothesis is that the bovine placenta is more permeable to fetal-derived products than described elsewhere. Samples of placentomes, chorion, endometrium, maternal peripheral blood leukocytes and blood plasma were collected during early gestation and processed for nested-PCR for eGFP and testis-specific Y-encoded protein (TSPY), western blotting and immunohistochemistry for eGFP detection, as well as transmission electron microscopy to verify the level of interaction between maternal and fetal cells. TSPY and eGFP DNA were present in the blood of cows carrying male pregnancies at day 60 of pregnancy. Protein and mRNA of eGFP were observed in the trophoblast and uterine tissues. In the placentomes, the protein expression was weak in the syncytial regions, but intense in neighboring cells on both sides of the fetal-maternal interface. Ultrastructurally, our samples from t-eGFP expressing NT pregnancies showed to be normal, such as the presence of interdigitating structures between fetal and maternal cells. In addition, channels-like structures were present in the trophoblast cells. Data suggested that there is a delivery of fetal contents to the maternal system on both systemic and local levels that involved nuclear acids and proteins. It not clear the mechanisms involved in the transfer of fetal-derived molecules to the maternal system. This delivery may occur through nonclassical protein secretion; throughout transtrophoblastic-like channels and/or by apoptotic processes previously described. In conclusion, the bovine synepitheliochorial placenta displays an intimate fetal-maternal interaction, similar to other placental types for instance human and mouse.
Modern banking, collection, compatibility testing and storage of blood and blood components.
Green, L; Allard, S; Cardigan, R
2015-01-01
The clinical practice of blood transfusion has changed considerably over the last few decades. The potential risk of transfusion transmissible diseases has directed efforts towards the production of safe and high quality blood. All transfusion services now operate in an environment of ever-increasing regulatory controls encompassing all aspects of blood collection, processing and storage. Stringent donor selection, identification of pathogens that can be transmitted through blood, and development of technologies that can enhance the quality of blood, have all led to a substantial reduction in potential risks and complications associated with blood transfusion. In this article, we will discuss the current standards required for the manufacture of blood, starting from blood collection, through processing and on to storage. © 2014 The Association of Anaesthetists of Great Britain and Ireland.
Donor vigilance data of a blood transfusion service: A multicenter analysis.
Burkhardt, T; Dimanski, B; Karl, R; Sievert, U; Karl, A; Hübler, C; Tonn, T; Sopvinik, I; Ertl, H; Moog, R
2015-10-01
Donor vigilance is an important part of the quality management system of blood transfusion services. The evaluation of donor side effects helps to improve the donation process and donor compliance. The aim of the present study was to evaluate donor vigilance data in whole blood and plasmapheresis donors of a blood donor service. Donors fulfilling current national and European eligibility criteria underwent whole blood and plasmapheresis donation (PCS and MCS+ (Haemonetics, Braintree, USA), A 200 (Fenwal, Round Lake, USA). Whole blood was collected at fixed and mobile sites while plasmaphereses were performed at 8 plasma centers. From 2011 to 2013 donor information was provided for gender, age, body weight, height, first and repeat donation. Donors were monitored for venipuncture and circulatory associated side effects. The total incidences of adverse events were 5004 (0.56%) in repeat donors and 2111 (2.78%) in first time donors for whole blood donation and 3323 (1.01%) and 514 (7.96%) for plasmaphereses, respectively. Circulatory associated events were 2679 (0.30%) for whole blood donation and 1624 (0.49%) for plasmaphereses. Our donor vigilance data of a blood transfusion service show that whole blood and plasmapheresis are safe with low incidences of adverse events. Repeat donation and age are predictors for low rates of adverse events. On the other hand, first time donation and female gender were associated with higher incidences of adverse events. Copyright © 2015 Elsevier Ltd. All rights reserved.
Gaming the System: Developing an Educational Game for Securing Principles of Arterial Blood Gases.
Boyd, Cory Ann; Warren, Jonah; Glendon, Mary Ann
2016-01-01
This article describes the development process for creating a digital educational mini game prototype designed to provide practice opportunities for learning fundamental principles of arterial blood gases. Mini games generally take less than an hour to play and focus on specific subject matter. An interdisciplinary team of faculty from two universities mentored student game developers to design a digital educational mini game prototype. Sixteen accelerated bachelor of science in nursing students collaborated with game development students and playtested the game prototype during the last semester of their senior year in nursing school. Playtesting is a form of feedback that supports an iterative design process that is critical to game development. A 10-question survey was coupled with group discussions addressing five broad themes of an archetypical digital educational mini game to yield feedback on game design, play, and content. Four rounds of playtesting and incorporating feedback supported the iterative process. Accelerated bachelor of science in nursing student playtester feedback suggests that the digital educational mini game prototype has potential for offering an engaging, playful game experience that will support securing the fundamental principles of arterial blood gases. Next steps are to test the digital educational mini game for teaching and learning effectiveness. Copyright © 2016 Elsevier Inc. All rights reserved.
Fiber-based optic sensor for detecting human blood clot: present and future revival
NASA Astrophysics Data System (ADS)
Elshikeri, Nada; Bakhtiar, Hazri
2018-05-01
Sustaining human’s life-frame away from being impeded by the clot - ghost term, we attempt to approach a mobile fiber-based optical sensor (f-s) for detecting blood clot in a blood vessel (intra-arteries/veins). Blood vessels are the part of the circulatory system that transport blood throughout the human body, thus their significance of being protected arise to the monograph focus. MRI (magnetic resonance imaging), X-rays and other medical instruments are diagnostic immobility techniques with a slackest interval. The corer causation of fiber-based optical sensor is to detect a clump of blood in the bloodstream by providing a prompt mobile diagnostic intervals preserving last-minutes-breath of human’s life. The detector (f-s) has been etched by diluting sulphuric acid ~10% at certain zone to sensate its function. The in-vitro monograph peaks its maximal monitoring when the sensor is attached to Raman Spectroscopy (RS) setup. RS quantifies the relative intensities of fibrinogen bond, which is the first type of blood coagulation elements of blood plasma. Blood coagulation parameters are the major concern of the monograph investigation, such as total haemoglobin (tHb), clotting reaction time (t), clot progression time (t2), maximum clot amplitude (ma) and mean refractive index (r). A blood sample will be drawn from the patient and after centrifugation to separate blood plasma from its constituents, then an immediate sloshing of blood plasma in the (f-s) packet which has its plug-in to RS. Estimating the quantitative analysis of blood sample concentration, RS will determine the presence of coagulation in terms of intensity and medical procedures will dominate the treatment process. Thus, the suggestive monograph provides a definite instrument for investigating blood coagulation intra-arteries/veins promptly.
NASA Astrophysics Data System (ADS)
Korb, H.; Hoeft, A.; Hellige, G.
1984-10-01
Previous studies have shown that intramyocardial blood volume does not vary to a major extent even during extreme variation of hemodynamics and coronary vascular tone. Based on a constant intramyocardial blood volume it is therefore possible to calculate tissue blood flow from the mean transit time of an intravascular tracer. The purpose of this study was to develop a clinically applicable method for measurement of coronary blood flow. The new method was based on indocyanine green, a dye which is bound to albumin and intravasally detectable by means of a fiberoptic catheter device. One fiberoptic catheter was placed in the aortic root and another in the coronary sinus. After central venous dye injection the resulting arterial and coronary venous dye dilution curves were processed on-line by a micro-computer. The mean transit time as well as myocardial blood flow were calculated from the step response function of the deconvoluted arterial and coronary venous signals. Reference flow was determined with an extracorporeal electromagnetic flowprobe within a coronary sinus bypass system. 38 steady states with coronary blood flow ranging from 49 - 333 ml/min*100g were analysed in 5 dogs. Mean transit times varied from 2.9 to 16.6 sec. An average intracoronary blood volume of 13.9 -7 1.8 m1/100g was calculated. The correlation between flow determined by the dye dilution technique and flow measured with the reference method was 0.98. According to these results determination of coronary blood flow with a double fiberoptic system and indocyanine green should be possible even under clinical conditions. Furthermore, the arterial and coronary venous oxygen saturation can be monitored continuously by the fiberoptic catheters. Therefore, additional information about the performance of the heart such as myocardial oxygen consumption and myocardial efficiency is available with the same equipment.
Evaluation of BACTEC 9240 blood culture system by using high-volume aerobic resin media.
Schwabe, L D; Thomson, R B; Flint, K K; Koontz, F P
1995-01-01
The BACTEC 9240 blood culture system (Becton Dickinson Diagnostic Instrument Systems, Sparks, Md.) is one of three automated, continuous-monitoring systems that is widely used in clinical laboratories. The BACTEC 9240 was compared with the BACTEC NR 660 for the detection of organisms and bacteremic episodes; time to detection of positive cultures; number of false-positive and false-negative cultures; and time needed to load, process, and perform quality control functions by using high-volume aerobic media. Blood specimens (5,282) were inoculated in equal volumes (5 to 10 ml per bottle) into BACTEC Plus Aerobic/F (9240 system) and BACTEC Plus NR26 (660 system) bottles. Clinically significant isolates were detected in 6.6% of cultures, representing 348 microorganisms and 216 bacteremic episodes. Two hundred forty-eight microorganisms were detected by both systems, 48 by the 9240 only and 52 by the 660 only (P = not significant). Of the bacteremic episodes, 158 were detected by both systems, 27 by the 9240 only and 31 by the 660 only (P = not significant). Analysis of data by month revealed equivalent recovery rates for both systems, with the exception of a 30-day period at one study site during which the 660 system detected significantly more microorganisms. Following a proprietary hardware design retrofit of the 9240 instrument, detection rates were again equivalent for the remaining three months at this study site. Positive cultures detected by both systems were detected an average of 4.3 h faster by the 9240 system (21 versus 25.3 h). The numbers of false-positive cultures for the 9240 and 660 systems were 40 (1.0%) and 9 ( < 1.0%), respectively.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:7494044
77 FR 71173 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-29
... the Military Health System (MHS) with a comprehensive enterprise wide Blood Donor Management System (BDMS) and a Blood Management Blood Bank and Transfusion Service (BMBB/TS). The Blood Donor Management... DoD's Blood Program capabilities for Donor Centers through the seamless integration of blood products...
Ultra-fast, label-free isolation of circulating tumor cells from blood using spiral microfluidics.
Warkiani, Majid Ebrahimi; Khoo, Bee Luan; Wu, Lidan; Tay, Andy Kah Ping; Bhagat, Ali Asgar S; Han, Jongyoon; Lim, Chwee Teck
2016-01-01
Circulating tumor cells (CTCs) are rare cancer cells that are shed from primary or metastatic tumors into the peripheral blood circulation. Phenotypic and genetic characterization of these rare cells can provide important information to guide cancer staging and treatment, and thus further research into their characteristics and properties is an area of considerable interest. In this protocol, we describe detailed procedures for the production and use of a label-free spiral microfluidic device to allow size-based isolation of viable CTCs using hydrodynamic forces that are present in curvilinear microchannels. This spiral system enables us to achieve ≥ 85% recovery of spiked cells across multiple cancer cell lines and 99.99% depletion of white blood cells in whole blood. The described spiral microfluidic devices can be produced at an extremely low cost using standard microfabrication and soft lithography techniques (2-3 d), and they can be operated using two syringe pumps for lysed blood samples (7.5 ml in 12.5 min for a three-layered multiplexed chip). The fast processing time and the ability to collect CTCs from a large patient blood volume allows this technique to be used experimentally in a broad range of potential genomic and transcriptomic applications.
Bassingthwaighte, James B; Raymond, Gary M; Dash, Ranjan K; Beard, Daniel A; Nolan, Margaret
2016-01-01
The 'Pathway for Oxygen' is captured in a set of models describing quantitative relationships between fluxes and driving forces for the flux of oxygen from the external air source to the mitochondrial sink at cytochrome oxidase. The intervening processes involve convection, membrane permeation, diffusion of free and heme-bound O2 and enzymatic reactions. While this system's basic elements are simple: ventilation, alveolar gas exchange with blood, circulation of the blood, perfusion of an organ, uptake by tissue, and consumption by chemical reaction, integration of these pieces quickly becomes complex. This complexity led us to construct a tutorial on the ideas and principles; these first PathwayO2 models are simple but quantitative and cover: (1) a 'one-alveolus lung' with airway resistance, lung volume compliance, (2) bidirectional transport of solute gasses like O2 and CO2, (3) gas exchange between alveolar air and lung capillary blood, (4) gas solubility in blood, and circulation of blood through the capillary syncytium and back to the lung, and (5) blood-tissue gas exchange in capillaries. These open-source models are at Physiome.org and provide background for the many respiratory models there.
Cardiopulmonary data-acquisition system
NASA Technical Reports Server (NTRS)
Crosier, W. G.; Reed, R. A.
1981-01-01
Computerized system controls and monitors bicycle and treadmill cardiovascular stress tests. It acquires and reduces stress data and displays heart rate, blood pressure, workload, respiratory rate, exhaled-gas composition, and other variables. Data are printed on hard-copy terminal every 30 seconds for quick operator response to patient. Ergometer workload is controlled in real time according to experimental protocol. Collected data are stored directly on tape in analog form and on floppy disks in digital form for later processing.
Lagacé-Wiens, Philippe R S; Adam, Heather J; Karlowsky, James A; Nichol, Kimberly A; Pang, Paulette F; Guenther, Jodi; Webb, Amanda A; Miller, Crystal; Alfa, Michelle J
2012-10-01
Matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry represents a revolution in the rapid identification of bacterial and fungal pathogens in the clinical microbiology laboratory. Recently, MALDI-TOF has been applied directly to positive blood culture bottles for the rapid identification of pathogens, leading to reductions in turnaround time and potentially beneficial patient impacts. The development of a commercially available extraction kit (Bruker Sepsityper) for use with the Bruker MALDI BioTyper has facilitated the processing required for identification of pathogens directly from positive from blood cultures. We report the results of an evaluation of the accuracy, cost, and turnaround time of this method for 61 positive monomicrobial and 2 polymicrobial cultures representing 26 species. The Bruker MALDI BioTyper with the Sepsityper gave a valid (score, >1.7) identification for 85.2% of positive blood cultures with no misidentifications. The mean reduction in turnaround time to identification was 34.3 h (P < 0.0001) in the ideal situation where MALDI-TOF was used for all blood cultures and 26.5 h in a more practical setting where conventional identification or identification from subcultures was required for isolates that could not be directly identified by MALDI-TOF. Implementation of a MALDI-TOF-based identification system for direct identification of pathogens from blood cultures is expected to be associated with a marginal increase in operating costs for most laboratories. However, the use of MALDI-TOF for direct identification is accurate and should result in reduced turnaround time to identification.
Tran, Nam K; Godwin, Zachary R; Steele, Amanda N; Wolf, Steven E; Palmieri, Tina L
2016-09-01
The goal of this study was to retrospectively evaluate the clinical impact of an accurate autocorrecting blood glucose monitoring system in children with severe burns. Blood glucose monitoring system accuracy is essential for providing appropriate intensive insulin therapy and achieving tight glycemic control in critically ill patients. Unfortunately, few comparison studies have been performed to evaluate the clinical impact of accurate blood glucose monitoring system monitoring in the high-risk pediatric burn population. Retrospective analysis of an electronic health record system. Pediatric burn ICU at an academic medical center. Children (aged < 18 yr) with severe burns (≥ 20% total body surface area) receiving intensive insulin therapy guided by either a noncorrecting (blood glucose monitoring system-1) or an autocorrecting blood glucose monitoring system (blood glucose monitoring system-2). Patient demographics, insulin rates, and blood glucose monitoring system measurements were collected. The frequency of hypoglycemia and glycemic variability was compared between the two blood glucose monitoring system groups. A total of 122 patient charts from 2001 to 2014 were reviewed. Sixty-three patients received intensive insulin therapy using blood glucose monitoring system-1 and 59 via blood glucose monitoring system-2. Patient demographics were similar between the two groups. Mean insulin infusion rates (5.1 ± 3.8 U/hr; n = 535 paired measurements vs 2.4 ± 1.3 U/hr; n = 511 paired measurements; p < 0.001), glycemic variability, and frequency of hypoglycemic events (90 vs 12; p < 0.001) were significantly higher in blood glucose monitoring system-1-treated patients. Compared with laboratory measurements, blood glucose monitoring system-2 yielded the most accurate results (mean ± SD bias: -1.7 ± 6.9 mg/dL [-0.09 ± 0.4 mmol/L] vs 7.4 ± 13.5 mg/dL [0.4 ± 0.7 mmol/L]). Blood glucose monitoring system-2 patients achieve glycemic control more quickly (5.7 ± 4.3 vs 13.1 ± 6.9 hr; p< 0.001) and stayed within the target glycemic control range longer compared with blood glucose monitoring system-1 patients (85.2% ± 13.9% vs 57.9% ± 29.1%; p < 0.001). Accurate autocorrecting blood glucose monitoring system optimizes intensive insulin therapy, improves tight glycemic control, and reduces the risk of hypoglycemia and glycemic variability. The use of an autocorrecting blood glucose monitoring system for intensive insulin therapy may improve glycemic control in severely burned children.
Is there a functional neural correlate of individual differences in cardiovascular reactivity?
Gianaros, Peter J; May, J Christopher; Siegle, Greg J; Jennings, J Richard
2005-01-01
The present study tested whether individuals who differ in the magnitude of their blood pressure reactions to a behavioral stressor also differ in their stressor-induced patterns of functional neural activation. Sixteen participants (7 men, 9 women aged 47 to 72 years) were classified as high (n = 8) or low (n = 8) blood pressure reactors by the magnitude and temporal consistency of their systolic blood pressure (SBP) reaction to a Stroop color-word interference stressor. Both high and low SBP reactors completed this Stroop stressor while their task-related changes in blood pressure and functional neural activity were assessed in a blocked functional magnetic resonance imaging design. In both high and low SBP reactors, the Stroop-stressor engaged the anterior cingulate, orbitofrontal, insular, posterior parietal, and the dorsolateral prefrontal regions of the cortex, the thalamus, and the cerebellum. Compared with low reactors, however, high reactors not only showed a larger magnitude increase in SBP to the Stroop stressor, but also an increased activation of the posterior cingulate cortex. A behavioral stressor that is used widely in cardiovascular reactivity research, the Stroop stressor, engages brain systems that are thought to support both stressor processing and cardiovascular reactivity. Increased activation of the posterior cingulate, a brain region implicated in vigilance to the environment and evaluative emotional processes, may be a functional neural correlate of an individual's tendency to show large-magnitude (exaggerated) blood pressure reactions to behavioral stressors.
Oral warfarin affects peripheral blood leukocyte IL-6 and TNFα production in rats.
Popov, Aleksandra; Belij, Sandra; Subota, Vesna; Zolotarevski, Lidija; Mirkov, Ivana; Kataranovski, Dragan; Kataranovski, Milena
2013-01-01
Warfarin is a Vitamin K (VK) antagonist that affects Vitamin K-dependent (VKD) processes, including blood coagulation, as well as processes unrelated to hemostasis such as bone growth, calcification, and growth of some cell types. In addition, warfarin exerts influence on some non-VKD-related activities, including anti-tumor and immunomodulating activity. With respect to the latter, both immune stimulating and suppressive effects have been noted in different experimental systems. To explore the in vivo immunomodulatory potential of warfarin on one type of activity (i.e., cytokine production) in two different immune cell populations (i.e., mononuclear or polymorphonuclear cells), effects of subchronic oral warfarin intake in rats on pro-inflammatory cytokine (i.e., TNFα, IL-6) production by peripheral blood mononuclear and polymorphonuclear cells (granulocytes) was examined. Differential effects of warfarin intake on TNFα and IL-6 were noted, depending on the type of peripheral blood leukocytes and on the cytokine examined. Specifically, a lack of effect on TNFα and a priming of IL-6 production by mononuclear cells along with a decrease in TNFα and a lack of effect on IL-6 in polymorphonuclear cells were seen in warfarin-exposed hosts. The cell- and cytokine-dependent effects from subchronic oral warfarin intake on peripheral blood leukocytes demonstrated in this study could, possibly, differentially affect reactions mediated by these cells. Ultimately, the observed effects in rats might have implications for those humans who are on long-term/prolonged warfarin therapy.
The Effect of Knowledge Linking Levels in Biology Lessons upon Students' Knowledge Structure
ERIC Educational Resources Information Center
Wadouh, Julia; Liu, Ning; Sandmann, Angela; Neuhaus, Birgit J.
2014-01-01
Knowledge structure is an important aspect for defining students' competency in biology learning, but how knowledge structure is influenced by the teaching process in naturalistic biology classroom settings has scarcely been empirically investigated. In this study, 49 biology lessons in the teaching unit "blood and circulatory system" in…
Computer Model of Aspirin bound to Human Serum Albumin
NASA Technical Reports Server (NTRS)
1989-01-01
Contributes to many transport and regulatory processes and has multifunctional binding properties which range form various metals, to fatty acids, hormones, and a wide spectrum of therapeutic drugs. The most abundant protein of the circulatory system. It binds and transports an incredible variety of biological and pharmaceutical ligands throughout the blood stream.
76 FR 8349 - Proposed Collection; Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-14
... provides the Military Health System (MHS) with a comprehensive enterprise wide Blood Donor Management System (DBMS) and Blood Transfusion Management System (BTMS) with capabilities to manage blood donors... donors, patients, and products; automated, blood order issue, and transfusion records; manage enterprise...
Novel Wearable Device for Blood Leakage Detection during Hemodialysis Using an Array Sensing Patch
Du, Yi-Chun; Lim, Bee-Yen; Ciou, Wei-Siang; Wu, Ming-Jui
2016-01-01
Hemodialysis (HD) is a clinical treatment that requires the puncturing of the body surface. However, needle dislodgement can cause a high risk of blood leakage and can be fatal to patients. Previous studies proposed several devices for blood leakage detection using optical or electrical techniques. Nonetheless, these methods used single-point detection and the design was not suitable for multi-bed monitoring. This study proposed a novel wearable device for blood leakage monitoring during HD using an array sensing patch. The array sensing patch combined with a mapping circuit and a wireless module could measure and transmit risk levels. The different risk levels could improve the working process of healthcare workers, and enhance their work efficiency and reduce inconvenience due to false alarms. Experimental results showed that each point of the sensing array could detect up to 0.1 mL of blood leakage and the array sensing patch supports a risk level monitoring system up to 8 h to alert healthcare personnel of pertinent danger to the patients. PMID:27294927
Georgieva, Julia V; Hoekstra, Dick; Zuhorn, Inge S
2014-11-17
The blood-brain barrier acts as a physical barrier that prevents free entry of blood-derived substances, including those intended for therapeutic applications. The development of molecular Trojan horses is a promising drug targeting technology that allows for non-invasive delivery of therapeutics into the brain. This concept relies on the application of natural or genetically engineered proteins or small peptides, capable of specifically ferrying a drug-payload that is either directly coupled or encapsulated in an appropriate nanocarrier, across the blood-brain barrier via receptor-mediated transcytosis. Specifically, in this process the nanocarrier-drug system ("Trojan horse complex") is transported transcellularly across the brain endothelium, from the blood to the brain interface, essentially trailed by a native receptor. Naturally, only certain properties would favor a receptor to serve as a transporter for nanocarriers, coated with appropriate ligands. Here we briefly discuss brain microvascular endothelial receptors that have been explored until now, highlighting molecular features that govern the efficiency of nanocarrier-mediated drug delivery into the brain.
Critical issues for engineering cord blood stem cells to produce insulin.
Denner, Larry; Urban, Randall J
2008-09-01
The objectives of using cord blood stem cells for treating type 1 diabetes are simple in principle yet complex in biological and molecular mechanisms. These are defined by the complexity of the insulin-producing unit of the pancreas, the islet. Islets are composed of various cell types that arise from diverse lineages and communicate by hormones, growth factors and small-molecule mediators. These processes are regulated by integration of signal transduction pathways. While advances have been made to engineer umbilical cord blood stem cells to produce insulin, these studies only illuminate the potential of such cells to fulfil a necessary, but not sufficient, requirement for transplantation. The challenges ahead demand detailed understanding of molecular mechanisms to move from an opportunistic, phenotypic approach to transplantation and amelioration of blood glucose, to an orderly and logical approach to a biologically and medically meaningful solution. The issues include expansion to generate large numbers of cells, self-renewal to regulate the destiny of cord blood stem cells to repopulate the hematopoietic system, and multipotency of stem cells to generate the distinct cell types of an islet.
NASA Technical Reports Server (NTRS)
1992-01-01
Organon Teknika Corporation's REDY 2000 dialysis machine employs technology originally developed under NASA contract by Marquardt Corporation. The chemical process developed during the project could be applied to removing toxic waste from used dialysis fluid. This discovery led to the development of a kidney dialysis machine using "sorbent" dialysis, a method of removing urea from human blood by treating a dialysate solution. The process saves electricity and, because the need for a continuous water supply is eliminated, the patient has greater freedom.
Role of proteoglycans in neuro-inflammation and central nervous system fibrosis.
Heindryckx, Femke; Li, Jin-Ping
2018-01-31
Fibrosis is defined as the thickening and scarring of connective tissue, usually as a consequence of tissue damage. The central nervous system (CNS) is special in the sense that fibrogenic cells are restricted to vascular and meningeal areas. Inflammation and the disruption of the blood-brain barrier can lead to the infiltration of fibroblasts and trigger fibrotic response. While the initial function of the fibrotic tissue is to restore the blood-brain barrier and to limit the site of injury, it also demolishes the structure of extracellular matrix and impedes the healing process by producing inhibitory molecules and forming a physical and biochemical barrier that prevents axon regeneration. As a major constituent in the extracellular matrix, proteoglycans participate in the neuro-inflammation, modulating the fibrotic process. In this review, we will discuss the pathophysiology of fibrosis during acute injuries of the CNS, as well as during chronic neurodegenerative conditions such as Alzheimer's disease, Parkinson's disease, multiple sclerosis and age-related neurodegeneration with focus on the functional roles of proteoglycans. Copyright © 2017 International Society of Matrix Biology. Published by Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Yamada, Masayoshi; Fukuzawa, Masayuki; Kitsunezuka, Yoshiki; Kishida, Jun; Nakamori, Nobuyuki; Kanamori, Hitoshi; Sakurai, Takashi; Kodama, Souichi
1995-05-01
In order to detect pulsation from a series of noisy ultrasound-echo moving images of a newborn baby's head for pediatric diagnosis, a digital image processing system capable of recording at the video rate and processing the recorded series of images was constructed. The time-sequence variations of each pixel value in a series of moving images were analyzed and then an algorithm based on Fourier transform was developed for the pulsation detection, noting that the pulsation associated with blood flow was periodically changed by heartbeat. Pulsation detection for pediatric diagnosis was successfully made from a series of noisy ultrasound-echo moving images of newborn baby's head by using the image processing system and the pulsation detection algorithm developed here.
NASA Astrophysics Data System (ADS)
Wiedemair, W.; Tuković, Ž.; Jasak, H.; Poulikakos, D.; Kurtcuoglu, V.
2012-02-01
The complex interaction between an ultrasound-driven microbubble and an enclosing capillary microvessel is investigated by means of a coupled, multi-domain numerical model using the finite volume formulation. This system is of interest in the study of transient blood-brain barrier disruption (BBBD) for drug delivery applications. The compliant vessel structure is incorporated explicitly as a distinct domain described by a dedicated physical model. Red blood cells (RBCs) are taken into account as elastic solids in the blood plasma. We report the temporal and spatial development of transmural pressure (Ptm) and wall shear stress (WSS) at the luminal endothelial interface, both of which are candidates for the yet unknown mediator of BBBD. The explicit introduction of RBCs shapes the Ptm and WSS distributions and their derivatives markedly. While the peak values of these mechanical wall parameters are not affected considerably by the presence of RBCs, a pronounced increase in their spatial gradients is observed compared to a configuration with blood plasma alone. The novelty of our work lies in the explicit treatment of the vessel wall, and in the modelling of blood as a composite fluid, which we show to be relevant for the mechanical processes at the endothelium.
The regulatory pendulum in transfusion medicine.
Farrugia, Albert
2002-10-01
Blood banking and the manufacture of blood products have been relatively outside the influence of regulatory authorities. Several developments contributed to a revision of this environment. The transmission of acquired immunodeficiency syndrome by blood products changed the perception of blood product safety and also spawned litigation and governmental inquiries. The blood banking industry has embraced, with varying degrees of enthusiasm, the principles of systematic quality management and good manufacturing practice, which has created a substantial subindustry and has contributed to a disproportionate focus on product quality. Conventional market forces have also gradually penetrated the traditional blood economies. The public and political focus has resulted in regulatory and policy efforts being concentrated on inappropriate areas. Several of the safety efforts can be arguably described as cost-ineffective while diverting attention and resources from more important issues. An improved integration into mainstream public health policy and incorporation of objectively measured risks into regulatory policy would do much to enhance the quality of the transfusion system. This can be achieved if regulators themselves are overseen through a process that ensures performance and accountability against objective and predefined standards. A further beneficial outcome from this approach could be the harmonization of blood safety and policy measures, the need for which is being felt increasingly worldwide. Copyright 2002, Elsevier Science (USA)
Quantification of blood volume by electrical impedance tomography using a tissue-equivalent phantom.
Sadleir, R; Fox, R
1998-11-01
An in vivo electrical impedance tomography (EIT) system was designed to accurately estimate quantities of intra-peritoneal blood in the abdominal cavity. For this it is essential that the response is relatively independent of the position of the high conductivity anomaly (blood) in the body. The sensitivity of the system to the introduction of blood-equivalent resistivity anomalies was assessed by using a cylindrical tissue-equivalent phantom. It was found that a satisfactorily uniform response of the system in both radial (transverse) and axial (longitudinal) directions in the phantom could be achieved by filtering resistivity profile images obtained by EIT measurement, and by using extended electrodes to collect data. Post-processing of single impedance images gave rise to a quantity denoted the resistivity index. A filter was then used to remove the remaining radial variation of the resistivity index. It was calculated by evaluating the resistivity index of a number of theoretically calculated images, and constructing a correction filter similar to those used to remove lens imperfections, such as coma, in optical components. The 30% increase in the resistivity index observed when an anomaly was moved to the maximum extent allowed by the filter calculation (0.75 of the phantom radius) was reduced by the filter to 6%. A study of the axial dependence observed in the resistivity index using electrodes extended in the axial direction by +/-5 cm found that the variation in resistivity index with axial position was about half of that observed using small circular electrodes similar to those used in the Sheffield mark I system.
Chunhui, Yang; Guohui, Bian; Hong, Yang; Xiaopu, Xiao; Zherong, Bai; Mingyuan, Wang; Xinsheng, Zhang; Juanjuan, Wang; Changqing, Li; Wuping, Li
2013-12-01
Pathogen reduction technology is an important process in the blood safety system, including solvent/detergent treatment, filtration and methylene blue-photochemical technology (MB-PCT). To investigate the quality of MB-PCT-treated plasma, plasma samples from four Chinese blood centers were analyzed over 12 months of storage to determine the recovery of activities and levels of various plasma proteins. Ten plasma units each from the Suzhou, Yancheng, Chongqing and Shandong blood centers were divided into two aliquots. One was subjected to treatment with one of two methylene blue-photochemical technology instruments and the other was used as control. The treated and untreated sample pairs were stored at -30°C. The recovery rates of coagulation factors, inhibitor proteins, total protein, immunoglobulins, and complement proteins were measured at different time points after storage. The mean recovery of most proteins exceeded 80% after MB treatment. The exceptions were factor XI and fibrinogen, of which only 71.3-74% and 69.0-92.3% were retained during storage. The two equipment types differed in terms of residual MB concentration in the plasma samples (0.18 μM and 0.29 μM, respectively). They had similar protein recovery rates at 0.5 month but differed at later time points. The four blood centers differed significantly with regard to factor II, V, VIII and fibrinogen activities. Only the samples from the Shandong blood center met the methylene blue treated fresh frozen plasma requirement. The major factor that influenced the quality of the MB-FFP samples was the time taken between blood collection and storage. Methylene blue treated plasma showed reduced coagulation factor (CF) activity and protein levels. The MB treatment-induced damage to the proteins was acceptable at the four Chinese blood centers, but the quality of the MB-treated plasma in general was not satisfactory. The main factor affecting plasma quality may be the duration of the collection and processing. Copyright © 2013 Elsevier Ltd. All rights reserved.
Michałowski, Jarosław M; Matuszewski, Jacek; Droździel, Dawid; Koziejowski, Wojciech; Rynkiewicz, Andrzej; Jednoróg, Katarzyna; Marchewka, Artur
2017-06-01
In the present simultaneous EEG/ECG-fMRI study we compared the temporal and spatial characteristics of the brain responses and the cardiac activity during fear picture processing between spider, blood-injection-injury (BII) and social fearful as well as healthy (non-fearful) volunteers. All participants were presented with two neutral and six fear-related blocks of pictures: two social, two spider and two blood/injection fear blocks. In a social fear block neutral images were occasionally interspersed with photographs of angry faces and social exposure scenes. In spider and blood/injection fear blocks neutral pictures were interspersed with spider fear-relevant and blood/injection pictures, respectively. When compared to healthy controls the social fear group responded with increased activations in the anterior orbital, middle/anterior cingulate and middle/superior temporal areas for pictures depicting angry faces and with a few elevated superior frontal activations for social exposure scenes. In the blood/injection fear group, heart rate was decreased and the activity in the middle/inferior frontal and visual processing regions was increased for blood/injection pictures. The HR decrease for blood/injection pictures correlated with increased frontal responses. In the spider fear group, spider fear-relevant pictures triggered increased activations within a broad subcortical and cortical neural fear network. The HR response for spider fear-relevant stimuli was increased and correlated with an increased insula and hippocampus activity. When compared to healthy controls, all fear groups showed higher LPP amplitudes for their feared cues and an overall greater P1 hypervigilance effect. Contrasts against the fear control groups showed that the increased responses for fear-specific stimuli are mostly related to specific fears and not to general anxiety proneness. The results suggest different engagement of cognitive evaluation and down-regulation strategies and an overall increased sensitization of the fear system in the three fear groups.
Hacker tracking Security system for HMI
NASA Astrophysics Data System (ADS)
Chauhan, Rajeev Kumar
2011-12-01
Conventional Supervisory control and data Acquisition (SCADA) systems use PC, notebook, thin client, and PDA as a Client. Nowadays the Process Industries are following multi shift system that's why multi- client of different category have to work at a single human Machine Interface (HMI). They may hack the HMI Display and change setting of the other client. This paper introduces a Hacker tracking security (HTS) System for HMI. This is developed by using the conventional and Biometric authentication. HTS system is developed by using Numeric passwords, Smart card, biometric, blood flow and Finger temperature. This work is also able to identify the hackers.
Antfolk, Maria; Laurell, Thomas
2017-05-01
Rare cells in blood, such as circulating tumor cells or fetal cells in the maternal circulation, posses a great prognostic or diagnostic value, or for the development of personalized medicine, where the study of rare cells could provide information to more specifically targeted treatments. When conventional cell separation methods, such as flow cytometry or magnetic activated cell sorting, have fallen short other methods are desperately sought for. Microfluidics have been extensively used towards isolating and processing rare cells as it offers possibilities not present in the conventional systems. Furthermore, microfluidic methods offer new possibilities for cell separation as they often rely on non-traditional biomarkers and intrinsic cell properties. This offers the possibility to isolate cell populations that would otherwise not be targeted using conventional methods. Here, we provide an extensive review of the latest advances in continuous flow microfluidic rare cell separation and processing with each cell's specific characteristics and separation challenges as a point of view. Copyright © 2017 Elsevier B.V. All rights reserved.
Red Blood Cell Agglutination for Blood Typing Within Passive Microfluidic Biochips.
Huet, Maxime; Cubizolles, Myriam; Buhot, Arnaud
2018-04-19
Pre-transfusion bedside compatibility test is mandatory to check that the donor and the recipient present compatible groups before any transfusion is performed. Although blood typing devices are present on the market, they still suffer from various drawbacks, like results that are based on naked-eye observation or difficulties in blood handling and process automation. In this study, we addressed the development of a red blood cells (RBC) agglutination assay for point-of-care blood typing. An injection molded microfluidic chip that is designed to enhance capillary flow contained anti-A or anti-B dried reagents inside its microchannel. The only blood handling step in the assay protocol consisted in the deposit of a blood drop at the tip of the biochip, and imaging was then achieved. The embedded reagents were able to trigger RBC agglutination in situ, allowing for us to monitor in real time the whole process. An image processing algorithm was developed on diluted bloods to compute real-time agglutination indicator and was further validated on undiluted blood. Through this proof of concept, we achieved efficient, automated, real time, and quantitative measurement of agglutination inside a passive biochip for blood typing which could be further generalized to blood biomarker detection and quantification.
Facilitation of blood donation amongst haemochromatosis patients.
Marrow, B; Clarkson, J; Chapman, C E; Masson, S
2015-08-01
The standard medical therapy for haemochromatosis is iron removal by regular phlebotomy. Current guidelines suggest that this blood should be made available through national blood services. Here, we describe a pilot facilitating the process of blood donation amongst uncomplicated haemochromatosis patients. At a dedicated clinic, patients with uncomplicated haemochromatosis interested in becoming blood donors were offered an information leaflet and self-referral application. Upon receipt, members of the local Blood Service contacted them to confirm eligibility to donate. Data on demographics and clinical characteristics, including HFE (high Fe) genotype, co-morbidities, alcohol consumption and body mass index, were collected. Since establishing the clinic, 140 patients have attended (93 male) with median age 57. Most (n = 125; 89%) had uncomplicated haemochromatosis. Of these, 55 were potentially eligible blood donors. Amongst those eligible, there are now 29 regular blood donors, including 23 new. There is an interest and willingness to donate blood through the Blood Service amongst uncomplicated haemochromatosis patients undergoing therapeutic phlebotomy. Since the introduction of this facilitation process, we have significantly increased the number of regular donors amongst this cohort. If this process was to be replicated more widely across the UK, this could have a significant impact on the blood donor pool. © 2015 British Blood Transfusion Society.
Jiang, Ludi; Chen, Jiahua; He, Yusu; Zhang, Yanling; Li, Gongyu
2016-02-01
The blood-brain barrier (BBB), a highly selective barrier between central nervous system (CNS) and the blood stream, restricts and regulates the penetration of compounds from the blood into the brain. Drugs that affect the CNS interact with the BBB prior to their target site, so the prediction research on BBB permeability is a fundamental and significant research direction in neuropharmacology. In this study, we combed through the available data and then with the help of support vector machine (SVM), we established an experiment process for discovering potential CNS compounds and investigating the mechanisms of BBB permeability of them to advance the research in this field four types of prediction models, referring to CNS activity, BBB permeability, passive diffusion and efflux transport, were obtained in the experiment process. The first two models were used to discover compounds which may have CNS activity and also cross the BBB at the same time; the latter two were used to elucidate the mechanism of BBB permeability of those compounds. Three optimization parameter methods, Grid Search, Genetic Algorithm (GA), and Particle Swarm Optimization (PSO), were used to optimize the SVM models. Then, four optimal models were selected with excellent evaluation indexes (the accuracy, sensitivity and specificity of each model were all above 85%). Furthermore, discrimination models were utilized to study the BBB properties of the known CNS activity compounds in Chinese herbs and this may guide the CNS drug development. With the relatively systematic and quick approach, the application rationality of traditional Chinese medicines for treating nervous system disease in the clinical practice will be improved.
Evaluation of canine red blood cell quality after processing with an automated cell salvage device.
Hofbauer, Nina; Windberger, Ursula; Schwendenwein, Ilse; Tichy, Alexander; Eberspächer, Eva
2016-05-01
To evaluate the properties of RBC concentrate harvested after processing fresh whole blood units from healthy dogs with an automated cell salvage device. Prospective, in vitro, experimental study. University teaching hospital. Sixteen healthy, privately owned dogs of various breeds. Fresh canine whole blood collected in bags with citrate phosphate dextrose adenine solution was processed with an automated cell salvage device and analyzed in vitro. Laboratory values determined before (baseline, from a catheter sample) and after processing RBCs (procRBCs) included a complete blood count, selected blood chemistry analytes, erythrocyte osmotic resistance, whole blood viscosity, RBC aggregation, and RBC deformability. Total recovery of RBCs was 80% ± 12%. Hematocrit of the procRBCs yielded by the device was 77% ± 3.7% (mean ± standard deviation). Gross morphology of the RBCs remained unchanged. The mean corpuscular volume, erythrocyte osmotic resistance, RBC deformability, RBC aggregation, and the activity of lactate dehydrogenase showed minor but statistically significant changes from baseline. No differences in the concentrations of free hemoglobin were observed. Whole blood viscosity was less in the procRBCs. Seventy-seven percent (mean) of the platelets were washed out, while a mean of 57% of the leukocytes remained in the procRBCs. Although processing canine blood with this automated cell salvage device leads to slight changes in some properties of RBCs, most of these changes are comparable to changes seen in human blood after processing. Present data indicate that the use of this cell salvage device does not induce changes in canine RBC concentrate that would preclude its use for transfusion. © Veterinary Emergency and Critical Care Society 2016.
NASA Astrophysics Data System (ADS)
Meissner, Robert; Sugden, Wade W.; Siekmann, Arndt F.; Denz, Cornelia
2018-02-01
All higher developed organisms contain complex hierarchical networks of arteries, veins and capillaries. These constitute the cardiovascular system responsible for supplying nutrients, gas and waste exchange. Diseases related to the cardiovascular system are among the main causes for death worldwide. In order to understand the processes leading to arteriovenous malformation, we studied hereditary hemorrhagic telangiectasia (HHT), which has a prevalence of 1:5000 worldwide and causes internal bleeding. In zebrafish, HHT is induced by mutation of the endoglin gene involved in HHT and observed to reduce red blood cell (RBC) flow to intersegmental vessels (ISVs) in the tail due to malformations of the dorsal aorta (DA) and posterior cardinal vein (PCV). However, these capillaries are still functional. Changes in the blood flow pattern are observed from in vivo data from zebrafish embryos through particle image velocimetry (PIV). Wall shear rates (WSRs) and blood flow velocities are obtained non-invasively with millisecond resolution. We observe significant increases of blood flow velocity in the DA for endoglin-deficient zebrafish embryos (mutants) at 3 days post fertilization. In the PCV, this increase is even more pronounced. We identified an increased similarity between the DA and the PCV of mutant fish compared to siblings, i.e., unaffected fish. To counteract the reduced RBC flow to ISVs we implement optical tweezers (OT). RBCs are steered into previously unperfused ISVs showing a significant increase of RBC count per minute. We discuss limitations with respect to biocompatibility of optical tweezers in vivo and determination of in vivo wall shear stress (WSS) connected to normal and endoglin-deficicent zebrafish embryos.
Wu, Pei-Yu; Yang, Shwu-Huey; Wong, Te-Chih; Chen, Tzen-Wen; Chen, His-Hsien; Chen, Tso-Hsiao; Chen, Yu-Tong
2015-01-01
In this cross-sectional study, we hypothesized that hemodialysis patients consuming greater processed meat is associated with hypertension risk, which can be partly explained by the high sodium content in processed meat. From September 2013 to May 2014, one hundred and four patients requiring chronic hemodialysis treatment were recruited from hemodialysis centers. Data on systolic blood pressure and diastolic blood pressure before receiving dialysis, and 3-day dietary records of the recruited patients were collected. HD patients with systolic and diastolic blood pressures greater than140 mmHg and higher than 90 mmHg, respectively, were considered hypertension risk. Protein foods were divided into 4 categories: red meat, white meat, soybeans, and processed meat (e.g., sausage and ham). In a model adjusted for energy intake and hypertension history, additional servings of processed meats was positively associated to systolic blood pressure >140 mmHg (odds ratio [95% confidence interval]: 2.1 [1.0–4.3]), and diastolic blood pressure > 90 mmHg (odds ratio: 2.5 [1.2–5.5]). After adjustment for dietary sodium contents or body mass index (BMI), most associations were substantially attenuated and were no longer significant. In systolic blood pressure greater than140 mmHg, one serving per day of red meats (β = -1.22, P < .05) and white meats (β = -0. 75, P = .05) was associated with a reduced risk compared with one serving per day of processed meats. Similarly, compared with one serving per day of processed meat, a reduced risk of diastolic blood pressure higher than 90 mmHg was associated with one serving per day of red meat (β = -1. 59, P < .05), white meat (β = -0. 62, P < .05). Thus, in these hemodialysis patients, intake of processed meat is significantly positively associated with higher blood pressure risk, and both sodium contents in processed meat and BMI significantly contributes to this association. PMID:26517837
Renero-C, Francisco-J
2018-01-01
Background: One of the complications of the diabetes mellitus is the amputation of the lower limbs. This complication may be developed after an insidious ulcer, that may be raised by the peripheral neuropathy or the ischaemic limb, and that the ulcer get infected. That is, to develop an ulcer, in the diabetic patient, three factors should be taken into the account, the autonomic nervous system, the blood supply and the inmune system. Methods: In this work, the thermogram is used to identify regions on the plantar skin with blood supply deficiencies and the behaviour of the thermoregulation process. Within the thermogram of the plantar skin, it can be identify local regions with low and high temperatures that corresponds to ischemic or inflammatory process on that part of the skin. Results: The findings within the 186 thermograms of diabetic patients, obtained from three hospitals and from INAOE facilities, showed, first, the thermograms of the plantar skin of two diabetic patients, acquired in two different times show that the temperature distribution and the average temperatures, vary slightly for a period of weeks. Second, the thermograms of two patients, who both developed insidious ulcers which evolved favourable, demonstrated the importance of the immune system and the drug therapy. These patients are, one who has a Charcot foot, and in the second one, the patient had loss the sensibility of the feet. Finally, the thermograms of two patients, showing abrupt temperature change within small regions in the plantar skin, are discussed. Conclusion: A diabetic patient, with an asymmetric thermogram, as physiological interpretation of the thermoregulation, may indicate a decrease of the blood supply, which may be corroborated by vascular ultrasound. The regions of abrupt temperature change, cold or hot spots, may correspond to ischaemic or inflammatory processes.
Renero-C, Francisco-J
2018-01-01
ABSTRACT Background: One of the complications of the diabetes mellitus is the amputation of the lower limbs. This complication may be developed after an insidious ulcer, that may be raised by the peripheral neuropathy or the ischaemic limb, and that the ulcer get infected. That is, to develop an ulcer, in the diabetic patient, three factors should be taken into the account, the autonomic nervous system, the blood supply and the inmune system. Methods: In this work, the thermogram is used to identify regions on the plantar skin with blood supply deficiencies and the behaviour of the thermoregulation process. Within the thermogram of the plantar skin, it can be identify local regions with low and high temperatures that corresponds to ischemic or inflammatory process on that part of the skin. Results: The findings within the 186 thermograms of diabetic patients, obtained from three hospitals and from INAOE facilities, showed, first, the thermograms of the plantar skin of two diabetic patients, acquired in two different times show that the temperature distribution and the average temperatures, vary slightly for a period of weeks. Second, the thermograms of two patients, who both developed insidious ulcers which evolved favourable, demonstrated the importance of the immune system and the drug therapy. These patients are, one who has a Charcot foot, and in the second one, the patient had loss the sensibility of the feet. Finally, the thermograms of two patients, showing abrupt temperature change within small regions in the plantar skin, are discussed. Conclusion: A diabetic patient, with an asymmetric thermogram, as physiological interpretation of the thermoregulation, may indicate a decrease of the blood supply, which may be corroborated by vascular ultrasound. The regions of abrupt temperature change, cold or hot spots, may correspond to ischaemic or inflammatory processes. PMID:29410772
Cord blood clinical processing, cryopreservation, and storage.
Elmoazzen, Heidi; Holovati, Jelena L
2015-01-01
Allogeneic umbilical cord blood (UCB) hematopoietic stem cell transplantation has become a crucial advancement in the treatment for a variety of diseases including hematopoietic and non-hematopoietic malignancies, BM failure syndromes, hemoglobinopathies, and metabolic and immunodeficiency disorders. It has been well documented that the success of UCB engraftment is tied to UCB banking processes, and now there are established guidelines for standardization of collection, banking, processing, and cryopreservation for unrelated UCB units with purpose of achieving consistent production of high quality placental and UCB units for administration. In 2011, Canada's Ministry of Health has announced Canada's first national, publicly funded umbilical cord blood bank, which aims to provide altruistic donations for unrelated allogeneic hematopoietic stem cell transplant. In this chapter, we describe specific protocols for clinical processing, cryopreservation, and storage of UCB used by the Canadian Blood Services National Public Umbilical Cord Blood Bank.
21 CFR 866.5470 - Hemoglobin immunological test system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...
21 CFR 866.5470 - Hemoglobin immunological test system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...
21 CFR 866.5470 - Hemoglobin immunological test system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...
21 CFR 866.5470 - Hemoglobin immunological test system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...
Engineering studies of vectorcardiographs in blood pressure measuring systems, appendix 2
NASA Technical Reports Server (NTRS)
Mark, R. G.
1975-01-01
The development of a cardiovascular monitoring system to noninvasively monitor the blood pressure and heart rate using pulse wave velocity was described. The following topics were covered: (1) pulse wave velocity as a measure of arterial blood pressure, (2) diastolic blood pressure and pulse wave velocity in humans, (3) transducer development for blood pressure measuring device, and (4) cardiovascular monitoring system. It was found, in experiments on dogs, that the pulse wave velocity is linearly related to diastolic blood pressure over a wide range of blood pressure and in the presence of many physiological perturbations. A similar relationship was observed in normal, young human males over a moderate range of pressures. Past methods for monitoring blood pressure and a new method based on pulse wave velocity determination were described. Two systems were tested: a Doppler ultrasonic transducer and a photoelectric plethysmograph. A cardiovascular monitoring system was described, including operating instructions.
de la Cuesta, F; Baldan-Martin, M; Mourino-Alvarez, L; Sastre-Oliva, T; Alvarez-Llamas, G; Gonzalez-Calero, L; Ruiz-Hurtado, G; Segura, J; Vivanco, F; Ruilope, L M; Barderas, M G
2016-01-01
Extracellular vesicles (EVs) are released to the bloodstream by certain cell types due to transport, activation and cell death processes. Blood count of EVs from platelet and endothelial origin has been proved to be a cardiovascular risk biomarker. Thus, EVs proteome might reflect the underlying cellular processes in hypertensive patients with albuminuria. Protein content of circulating EVs was analyzed by liquid chromatography coupled to mass spectrometry. EVs were isolated by an ultracentrifugation protocol optimized in order to avoid contamination by blood plasma proteins. Purity of the isolated fraction was verified by electronic and confocal microscopy, and by flow cytometry. We hereby show a method to isolate circulating EVs from hypertensive patients with/without albuminuria with high yield and purity. Besides, we provide a reference proteome of the EVs of these patients, composed of 2,463 proteins, and prove that the proteins carried by these vesicles are associated with crucial processes involved in the inherent cardiovascular risk. The proteome of circulating EVs is an interesting source of indicators in the evaluation of cardiovascular risk in hypertensive patients with renin-angiotensin system blockage. Copyright © 2015 SEHLELHA. Published by Elsevier España, S.L.U. All rights reserved.
Vernetti, Lawrence; Gough, Albert; Baetz, Nicholas; Blutt, Sarah; Broughman, James R.; Brown, Jacquelyn A.; Foulke-Abel, Jennifer; Hasan, Nesrin; In, Julie; Kelly, Edward; Kovbasnjuk, Olga; Repper, Jonathan; Senutovitch, Nina; Stabb, Janet; Yeung, Catherine; Zachos, Nick C.; Donowitz, Mark; Estes, Mary; Himmelfarb, Jonathan; Truskey, George; Wikswo, John P.; Taylor, D. Lansing
2017-01-01
Organ interactions resulting from drug, metabolite or xenobiotic transport between organs are key components of human metabolism that impact therapeutic action and toxic side effects. Preclinical animal testing often fails to predict adverse outcomes arising from sequential, multi-organ metabolism of drugs and xenobiotics. Human microphysiological systems (MPS) can model these interactions and are predicted to dramatically improve the efficiency of the drug development process. In this study, five human MPS models were evaluated for functional coupling, defined as the determination of organ interactions via an in vivo-like sequential, organ-to-organ transfer of media. MPS models representing the major absorption, metabolism and clearance organs (the jejunum, liver and kidney) were evaluated, along with skeletal muscle and neurovascular models. Three compounds were evaluated for organ-specific processing: terfenadine for pharmacokinetics (PK) and toxicity; trimethylamine (TMA) as a potentially toxic microbiome metabolite; and vitamin D3. We show that the organ-specific processing of these compounds was consistent with clinical data, and discovered that trimethylamine-N-oxide (TMAO) crosses the blood-brain barrier. These studies demonstrate the potential of human MPS for multi-organ toxicity and absorption, distribution, metabolism and excretion (ADME), provide guidance for physically coupling MPS, and offer an approach to coupling MPS with distinct media and perfusion requirements. PMID:28176881
Frégeau, Chantal J; Lett, C Marc; Fourney, Ron M
2010-10-01
A semi-automated DNA extraction process for casework samples based on the Promega DNA IQ™ system was optimized and validated on TECAN Genesis 150/8 and Freedom EVO robotic liquid handling stations configured with fixed tips and a TECAN TE-Shake™ unit. The use of an orbital shaker during the extraction process promoted efficiency with respect to DNA capture, magnetic bead/DNA complex washes and DNA elution. Validation studies determined the reliability and limitations of this shaker-based process. Reproducibility with regards to DNA yields for the tested robotic workstations proved to be excellent and not significantly different than that offered by the manual phenol/chloroform extraction. DNA extraction of animal:human blood mixtures contaminated with soil demonstrated that a human profile was detectable even in the presence of abundant animal blood. For exhibits containing small amounts of biological material, concordance studies confirmed that DNA yields for this shaker-based extraction process are equivalent or greater to those observed with phenol/chloroform extraction as well as our original validated automated magnetic bead percolation-based extraction process. Our data further supports the increasing use of robotics for the processing of casework samples. Crown Copyright © 2009. Published by Elsevier Ireland Ltd. All rights reserved.
Holographic quantitative imaging of sample hidden by turbid medium or occluding objects
NASA Astrophysics Data System (ADS)
Bianco, V.; Miccio, L.; Merola, F.; Memmolo, P.; Gennari, O.; Paturzo, Melania; Netti, P. A.; Ferraro, P.
2015-03-01
Digital Holography (DH) numerical procedures have been developed to allow imaging through turbid media. A fluid is considered turbid when dispersed particles provoke strong light scattering, thus destroying the image formation by any standard optical system. Here we show that sharp amplitude imaging and phase-contrast mapping of object hidden behind turbid medium and/or occluding objects are possible in harsh noise conditions and with a large field-of view by Multi-Look DH microscopy. In particular, it will be shown that both amplitude imaging and phase-contrast mapping of cells hidden behind a flow of Red Blood Cells can be obtained. This allows, in a noninvasive way, the quantitative evaluation of living processes in Lab on Chip platforms where conventional microscopy techniques fail. The combination of this technique with endoscopic imaging can pave the way for the holographic blood vessel inspection, e.g. to look for settled cholesterol plaques as well as blood clots for a rapid diagnostics of blood diseases.
Kang, Dong-Ku; Ali, M. Monsur; Zhang, Kaixiang; Huang, Susan S.; Peterson, Ellena; Digman, Michelle A.; Gratton, Enrico; Zhao, Weian
2014-01-01
Blood stream infection or sepsis is a major health problem worldwide, with extremely high mortality, which is partly due to the inability to rapidly detect and identify bacteria in the early stages of infection. Here we present a new technology termed ‘Integrated Comprehensive Droplet Digital Detection’ (IC 3D) that can selectively detect bacteria directly from milliliters of diluted blood at single-cell sensitivity in a one-step, culture- and amplification-free process within 1.5–4 h. The IC 3D integrates real-time, DNAzyme-based sensors, droplet microencapsulation and a high-throughput 3D particle counter system. Using Escherichia coli as a target, we demonstrate that the IC 3D can provide absolute quantification of both stock and clinical isolates of E. coli in spiked blood within a broad range of extremely low concentration from 1 to 10,000 bacteria per ml with exceptional robustness and limit of detection in the single digit regime. PMID:25391809
Investigation of flavonoid influence on peroxidation processes intensity in the blood
NASA Astrophysics Data System (ADS)
Navolokin, N. A.; Mudrak, D. A.; Plastun, I. L.; Bucharskaya, A. B.; Agandeeva, K. E.; Ivlichev, A. V.; Tychina, S. A.; Afanasyeva, G. A.; Polukonova, N. V.; Maslyakova, G. N.
2017-03-01
Influence of flavonoids on the intensity of peroxidation processes in the blood is investigated by numerical modeling and by experiment in vivo. As an example we consider the effects of flavonoid-containing extract of Helichrysum arenarium L. with antitumor activity on serum of rats with transplanted liver cancer PC-1. It was found that the content of malondialdehyde, lipid hydroperoxides and average mass molecules were decreased in animals with transplanted liver cancer after intramuscular and oral administration of Helichrysum arenarium L extract in a dose of 1000 mg/mL. The extract reduces the intensity of lipid peroxidation processes in animals. The compound formation possibility of flavonoids and products of lipid peroxidation is investigated by numerical simulations. Using the density functional theory method of molecular modeling, we analyze hydrogen bonds formation and their influence on IR - spectra and structure of molecular complex which is formed due to interaction between flavonoids and products of lipid peroxidation processes on example of naringine and malondialdehyde. We have found that naringine can form a steady molecular complex with malondialdehyde by hydrogen bonds formation. Thus, the application of Helichrysum arenarium L. extract for suppression processes of lipid peroxidation and activation of enzymatic and non-enzymatic antioxidant systems is promising.
Blood thinners are medicines that prevent blood clots from forming. They also keep existing blood clots from getting larger. Clots in your arteries, ... down your body's process of making clots. Antiplatelet drugs, such as aspirin, prevent blood cells called platelets ...
Code of Federal Regulations, 2014 CFR
2014-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2011 CFR
2011-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2012 CFR
2012-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
Code of Federal Regulations, 2013 CFR
2013-04-01
... STANDARDS FOR DIAGNOSTIC SUBSTANCES FOR LABORATORY TESTS Reagent Red Blood Cells § 660.34 Processing. (a... required blood group antigens specified in the labeling as present. (b) Products prepared from pooled red blood cells. If the product is recommended for the detection of unexpected antibodies, the pool shall be...
[Development of a continuous blood pressure monitoring and recording system].
Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin
2012-09-01
A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.
Storry, J R; Castilho, L; Chen, Q; Daniels, G; Denomme, G; Flegel, W A; Gassner, C; de Haas, M; Hyland, C; Keller, M; Lomas-Francis, C; Moulds, J M; Nogues, N; Olsson, M L; Peyrard, T; van der Schoot, C E; Tani, Y; Thornton, N; Wagner, F; Wendel, S; Westhoff, C; Yahalom, V
2016-08-01
The Working Party has met twice since the last report: in Seoul, South Korea 2014, and in London, UK 2015, both in association with the International Society of Blood Transfusion (ISBT) Congress. As in previous meetings, matters pertaining to blood group antigen nomenclature were discussed. Eleven new blood group antigens were added to seven blood group systems. This brings the current total of blood group antigens recognized by the ISBT to 346, of which 308 are clustered within 36 blood groups systems. The remaining 38 antigens are currently unassigned to a known blood group system.
Code of Federal Regulations, 2010 CFR
2010-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2013 CFR
2013-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2012 CFR
2012-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2014 CFR
2014-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Code of Federal Regulations, 2011 CFR
2011-04-01
... blood and red blood cells during storage and immediately before distribution. (iii) Storage temperature... GOOD MANUFACTURING PRACTICE FOR BLOOD AND BLOOD COMPONENTS Records and Reports § 606.160 Records. (a)(1..., processing, compatibility testing, storage and distribution of each unit of blood and blood components so...
Comparison of early period results of blood use in open heart surgery.
Huseyin, Serhat; Yuksel, Volkan; Guclu, Orkut; Turan, Fatma Nesrin; Canbaz, Suat; Ege, Turan; Sunar, Hasan
2016-01-01
Various adverse effects of homologous blood transfusion detected particularly in open heart surgery, in which it is frequently used, lead researchers to study on autologous blood use and to evaluate the patient's blood better. Due to the complications of homologous blood transfusion, development of techniques that utilize less transfusion has become inevitable. We aimed to evaluate the effects of acute normovolemic hemodilution (ANH) in patients undergoing open heart surgery. In this study, 120 patients who underwent open heart surgery were included. Patients were grouped into three: Autologous transfusion group (Group 1), homologous transfusion group (Group 2), and those received autologous blood and homologous blood products (Group 3). Patient data regarding preoperative characteristics, biochemical parameters, drainage, extubation time, duration of stay at intensive care, atrial fibrillation (AF) development, and hospital stay were recorded. A statistically significant difference ( P < 0.005) was found in favor of autologous group (Group 1) with respect to gender, body surface area, European System for Cardiac Operative Risk Evaluation, smoking, hematocrit levels, platelet counts, urea, C-reactive protein levels, protamine use, postoperative drainage, frequency of AF development, intubation period, stay at intensive care and hospital stay, and amount of used blood products. The use of autologous blood rather than homologous transfusion is not only attenuates side effects and complications of transfusion but also positively affects postoperative recovery process. Therefore, ANH can be considered as an easy, effective, and cheap technique during open heart surgery.
[Physiological features of skin ageing in human].
Tikhonova, I V; Tankanag, A V; Chemeris, N K
2013-01-01
The issue deals with the actual problem of gerontology, notably physiological features of human skin ageing. In the present review the authors have considered the kinds of ageing, central factors, affected on the ageing process (ultraviolet radiation and oxidation stress), as well as the research guidelines of the ageing changes in the skin structure and fuctions: study of mechanical properties, microcirculation, pH and skin thickness. The special attention has been payed to the methods of assessment of skin blood flow, and to results of investigations of age features of peripheral microhemodynamics. The laser Doppler flowmetry technique - one of the modern, noninvasive and extensively used methods for the assessmant of skin blood flow microcirculation system has been expanded in the review. The main results of the study of the ageing changes of skin blood perfusion using this method has been also presented.
Urinary Biomarkers of Brain Diseases.
An, Manxia; Gao, Youhe
2015-12-01
Biomarkers are the measurable changes associated with a physiological or pathophysiological process. Unlike blood, urine is not subject to homeostatic mechanisms. Therefore, greater fluctuations could occur in urine than in blood, better reflecting the changes in human body. The roadmap of urine biomarker era was proposed. Although urine analysis has been attempted for clinical diagnosis, and urine has been monitored during the progression of many diseases, particularly urinary system diseases, whether urine can reflect brain disease status remains uncertain. As some biomarkers of brain diseases can be detected in the body fluids such as cerebrospinal fluid and blood, there is a possibility that urine also contain biomarkers of brain diseases. This review summarizes the clues of brain diseases reflected in the urine proteome and metabolome. Copyright © 2016 The Authors. Production and hosting by Elsevier Ltd.. All rights reserved.
Ultrastructure of the digestive tract of Paradiplozoon homoion (Monogenea).
Konstanzová, V; Koubková, B; Kašný, M; Ilgová, J; Dzika, E; Gelnar, M
2015-04-01
Paradiplozoon homoion is a representative of blood-feeding ectoparasites from the family Diplozoidae (Polyopisthocotylea, Monogenea). Although these worms have been the subject of numerous taxonomical, phylogenetic and ecological studies, the ultrastructure of the alimentary system and related structures, as well as the mechanisms of essential processes like fish blood digestion, remain mostly unknown. Our observation of P. homoion using a transmission electron microscopy (TEM) revealed two main types of digestive cells-U-shaped haematin cells and connecting syncytium. Particular structures such as mouth cavity with specialised receptors, two oval-shaped muscular buccal suckers, pharynx surrounded with the glandular cells, oesophagus, the intestinal caeca with intact erythrocytes in the lumen, the apical pinocytotic fibrous surface complex and haematin vesicles of U-shaped cells have been shown in detail. According to our results, the P. homoion is degrading the blood components predominantly intracellularly.
Optical Microangiography Based on Optical Coherence Tomography
NASA Astrophysics Data System (ADS)
Reif, Roberto; Wang, Ruikang K.
Proper homeostasis regulation of in vivo biological systems requires microvascular blood perfusion, which is the process of delivering blood into the tissue's capillary beds. Abnormal tissue vascularization has been associated with various diseases such as cancer, diabetes, neurological disorders, wounds, and inflammation. Understanding the changes in the vascular network or microangiography will have an important role in determining the causes and developing potential treatments for these diseases. Optical coherence tomography (OCT) is a noninvasive method for imaging three-dimensional biological tissues with high resolution (~10 µm) and without requiring the use of contrast agents. In this chapter we review several techniques for using OCT to determine blood flow velocities and the vessel morphology (optical microangiography). Different techniques will be discussed with a brief explanation of their limitations. Also, methods for quantifying these images are presented, as well as the depiction of several applications.
How to maintain blood supply during computer network breakdown: a manual backup system.
Zeiler, T; Slonka, J; Bürgi, H R; Kretschmer, V
2000-12-01
Electronic data management systems using computer network systems and client/server architecture are increasingly used in laboratories and transfusion services. Severe problems arise if there is no network access to the database server and critical functions are not available. We describe a manual backup system (MBS) developed to maintain the delivery of blood products to patients in a hospital transfusion service in case of a computer network breakdown. All data are kept on a central SQL database connected to peripheral workstations in a local area network (LAN). Request entry from wards is performed via machine-readable request forms containing self-adhesive specimen labels with barcodes for test tubes. Data entry occurs on-line by bidirectional automated systems or off-line manually. One of the workstations in the laboratory contains a second SQL database which is frequently and incrementally updated. This workstation is run as a stand-alone, read-only database if the central SQL database is not available. In case of a network breakdown, the time-graded MBS is launched. Patient data, requesting ward and ordered tests/requests, are photocopied through a template from the request forms on special MBS worksheets serving as laboratory journal for manual processing and result report (a copy is left in the laboratory). As soon as the network is running again the data from the off-line period are entered into the primary SQL server. The MBS was successfully used at several occasions. The documentation of a 90-min breakdown period is presented in detail. Additional work resulted from the copy work and the belated manual data entry after restoration of the system. There was no delay in issue of blood products or result reporting. The backup system described has been proven to be simple, quick and safe to maintain urgent blood supply and distribution of laboratory results in case of unexpected network breakdown.
Preventing blood transfusion failures: FMEA, an effective assessment method.
Najafpour, Zhila; Hasoumi, Mojtaba; Behzadi, Faranak; Mohamadi, Efat; Jafary, Mohamadreza; Saeedi, Morteza
2017-06-30
Failure Mode and Effect Analysis (FMEA) is a method used to assess the risk of failures and harms to patients during the medical process and to identify the associated clinical issues. The aim of this study was to conduct an assessment of blood transfusion process in a teaching general hospital, using FMEA as the method. A structured FMEA was recruited in our study performed in 2014, and corrective actions were implemented and re-evaluated after 6 months. Sixteen 2-h sessions were held to perform FMEA in the blood transfusion process, including five steps: establishing the context, selecting team members, analysis of the processes, hazard analysis, and developing a risk reduction protocol for blood transfusion. Failure modes with the highest risk priority numbers (RPNs) were identified. The overall RPN scores ranged from 5 to 100 among which, four failure modes were associated with RPNs over 75. The data analysis indicated that failures with the highest RPNs were: labelling (RPN: 100), transfusion of blood or the component (RPN: 100), patient identification (RPN: 80) and sampling (RPN: 75). The results demonstrated that mis-transfusion of blood or blood component is the most important error, which can lead to serious morbidity or mortality. Provision of training to the personnel on blood transfusion, knowledge raising on hazards and appropriate preventative measures, as well as developing standard safety guidelines are essential, and must be implemented during all steps of blood and blood component transfusion.
Aristov, Alexander; Nosova, Ekaterina
2017-04-01
The paper focuses on research aimed at creating and testing a new approach to evaluate the processes of aggregation and sedimentation of red blood cells for purpose of its use in clinical laboratory diagnostics. The proposed method is based on photometric analysis of blood sample formed as a sessile drop. The results of clinical approbation of this method are given in the paper. Analysis of the processes occurring in the sample in the form of sessile drop during the process of blood cells sedimentation is described. The results of experimental studies to evaluate the effect of the droplet sample focusing properties on light radiation transmittance are presented. It is shown that this method significantly reduces the sample volume and provides sufficiently high sensitivity to the studied processes.
Bhagat, Ali Asgar S; Hou, Han Wei; Li, Leon D; Lim, Chwee Teck; Han, Jongyoon
2011-06-07
Blood is a highly complex bio-fluid with cellular components making up >40% of the total volume, thus making its analysis challenging and time-consuming. In this work, we introduce a high-throughput size-based separation method for processing diluted blood using inertial microfluidics. The technique takes advantage of the preferential cell focusing in high aspect-ratio microchannels coupled with pinched flow dynamics for isolating low abundance cells from blood. As an application of the developed technique, we demonstrate the isolation of cancer cells (circulating tumor cells (CTCs)) spiked in blood by exploiting the difference in size between CTCs and hematologic cells. The microchannel dimensions and processing parameters were optimized to enable high throughput and high resolution separation, comparable to existing CTC isolation technologies. Results from experiments conducted with MCF-7 cells spiked into whole blood indicate >80% cell recovery with an impressive 3.25 × 10(5) fold enrichment over red blood cells (RBCs) and 1.2 × 10(4) fold enrichment over peripheral blood leukocytes (PBL). In spite of a 20× sample dilution, the fast operating flow rate allows the processing of ∼10(8) cells min(-1) through a single microfluidic device. The device design can be easily customized for isolating other rare cells from blood including peripheral blood leukocytes and fetal nucleated red blood cells by simply varying the 'pinching' width. The advantage of simple label-free separation, combined with the ability to retrieve viable cells post enrichment and minimal sample pre-processing presents numerous applications for use in clinical diagnosis and conducting fundamental studies.