Sample records for body fluid testing

  1. Body fluid analysis: clinical utility and applicability of published studies to guide interpretation of today's laboratory testing in serous fluids.

    PubMed

    Block, Darci R; Algeciras-Schimnich, Alicia

    2013-01-01

    Requests for testing various analytes in serous fluids (e.g., pleural, peritoneal, pericardial effusions) are submitted daily to clinical laboratories. Testing of these fluids deviates from assay manufacturers' specifications, as most laboratory assays are optimized for testing blood or urine specimens. These requests add a burden to clinical laboratories, which need to validate assay performance characteristics in these fluids to exclude matrix interferences (given the different composition of body fluids) while maintaining regulatory compliance. Body fluid testing for a number of analytes has been reported in the literature; however, understanding the clinical utility of these analytes is critical because laboratories must address the analytic and clinical validation requirements, while educating clinicians on proper test utilization. In this article, we review the published data to evaluate the clinical utility of testing for numerous analytes in body fluid specimens. We also highlight the pre-analytic and analytic variables that need to be considered when reviewing published studies in body fluid testing. Finally, we provide guidance on how published studies might (or might not) guide interpretation of test results in today's clinical laboratories.

  2. 21 CFR 862.1435 - Ketones (nonquantitative) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test...) test system is a device intended to identify ketones in urine and other body fluids. Identification of... acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies...

  3. 21 CFR 862.1435 - Ketones (nonquantitative) test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test...) test system is a device intended to identify ketones in urine and other body fluids. Identification of... acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies...

  4. 21 CFR 862.1435 - Ketones (nonquantitative) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test...) test system is a device intended to identify ketones in urine and other body fluids. Identification of... acidity of body fluids) or ketosis (a condition characterized by increased production of ketone bodies...

  5. Multidimensional Raman spectroscopic signatures as a tool for forensic identification of body fluid traces: a review.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2011-11-01

    The analysis of body fluid traces during forensic investigations is a critical step in determining the key details of a crime. Several confirmatory and presumptive biochemical tests are currently utilized. However, these tests are all destructive, and no single method can be used to analyze all body fluids. This review outlines recent progress in the development of a novel universal approach for the nondestructive, confirmatory identification of body fluid traces using Raman spectroscopy. The method is based on the use of multidimensional spectroscopic signatures of body fluids and accounts for the intrinsic heterogeneity of dry traces and donor variation. The results presented here demonstrate that Raman spectroscopy has potential for identifying traces of semen, blood, saliva, sweat, and vaginal fluid with high confidence.

  6. 21 CFR 862.1630 - Protein (fractionation) test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... body fluids. Protein fractionations are used as an aid in recognizing abnormal proteins in body fluids...

  7. 21 CFR 862.1630 - Protein (fractionation) test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... body fluids. Protein fractionations are used as an aid in recognizing abnormal proteins in body fluids...

  8. 21 CFR 862.1630 - Protein (fractionation) test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... body fluids. Protein fractionations are used as an aid in recognizing abnormal proteins in body fluids...

  9. 21 CFR 862.1630 - Protein (fractionation) test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test... body fluids. Protein fractionations are used as an aid in recognizing abnormal proteins in body fluids...

  10. Presence and Persistence of Ebola or Marburg Virus in Patients and Survivors: A Rapid Systematic Review.

    PubMed

    Brainard, Julii; Pond, Katherine; Hooper, Lee; Edmunds, Kelly; Hunter, Paul

    2016-02-01

    The 2013-15 Ebola outbreak was unprecedented due to sustained transmission within urban environments and thousands of survivors. In 2014 the World Health Organization stated that there was insufficient evidence to give definitive guidance about which body fluids are infectious and when they pose a risk to humans. We report a rapid systematic review of published evidence on the presence of filoviruses in body fluids of infected people and survivors. Scientific articles were screened for information about filovirus in human body fluids. The aim was to find primary data that suggested high likelihood of actively infectious filovirus in human body fluids (viral RNA). Eligible infections were from Marburg virus (MARV or RAVV) and Zaire, Sudan, Taï Forest and Bundibugyo species of Ebola. Cause of infection had to be laboratory confirmed (in practice either tissue culture or RT-PCR tests), or evidenced by compatible clinical history with subsequent positivity for filovirus antibodies or inflammatory factors. Data were extracted and summarized narratively. 6831 unique articles were found, and after screening, 33 studies were eligible. For most body fluid types there were insufficient patients to draw strong conclusions, and prevalence of positivity was highly variable. Body fluids taken >16 days after onset were usually negative. In the six studies that used both assay methods RT-PCR tests for filovirus RNA gave positive results about 4 times more often than tissue culture. Filovirus was reported in most types of body fluid, but not in every sample from every otherwise confirmed patient. Apart from semen, most non-blood, RT-PCR positive samples are likely to be culture negative and so possibly of low infectious risk. Nevertheless, it is not apparent how relatively infectious many body fluids are during or after illness, even when culture-positive, not least because most test results come from more severe cases. Contact with blood and blood-stained body fluids remains the major risk for disease transmission because of the known high viral loads in blood.

  11. Body fluid matrix evaluation on a Roche cobas 8000 system.

    PubMed

    Owen, William E; Thatcher, Mindy L; Crabtree, Karolyn J; Greer, Ryan W; Strathmann, Frederick G; Straseski, Joely A; Genzen, Jonathan R

    2015-09-01

    Chemical analysis of body fluids is commonly requested by physicians. Because most commercial FDA-cleared clinical laboratory assays are not validated by diagnostic manufacturers for "non-serum" and "non-plasma" specimens, laboratories may need to complete additional validation studies to comply with regulatory requirements regarding body fluid testing. The objective of this report is to perform recovery studies to evaluate potential body fluid matrix interferences for commonly requested chemistry analytes. Using an IRB-approved protocol, previously collected clinical body fluid specimens (biliary/hepatic, cerebrospinal, dialysate, drain, pancreatic, pericardial, peritoneal, pleural, synovial, and vitreous) were de-identified and frozen (-20°C) until experiments were performed. Recovery studies (spiking with high concentration serum, control, and/or calibrator) were conducted using 10% spiking solution by volume; n=5 specimens per analyte/body fluid investigated. Specimens were tested on a Roche cobas 8000 system (c502, c702, e602, and ISE modules). In all 80 analyte/body fluid combinations investigated (including amylase, total bilirubin, urea nitrogen, carbohydrate antigen 19-9, carcinoembryonic antigen, cholesterol, chloride, creatinine, glucose, potassium, lactate dehydrogenase, lipase, rheumatoid factor, sodium, total protein, triglycerides, and uric acid), the average percent recovery was within predefined acceptable limits (less than ±10% from the calculated ideal recovery). The present study provides evidence against the presence of any systematic matrix interference in the analyte/body fluid combinations investigated on the Roche cobas 8000 system. Such findings support the utility of ongoing body fluid validation initiatives conducted to maintain compliance with regulatory requirements. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  12. 49 CFR 219.301 - Testing for reasonable cause.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... breath or body fluid testing, or both, to determine compliance with §§ 219.101 and 219.102 or a railroad... an employee that is required when an employee is required to provide a breath or body fluid specimen... breath testing. In addition to reasonable suspicion as described in § 219.300, the following...

  13. 49 CFR 219.301 - Testing for reasonable cause.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... breath or body fluid testing, or both, to determine compliance with §§ 219.101 and 219.102 or a railroad... an employee that is required when an employee is required to provide a breath or body fluid specimen... breath testing. In addition to reasonable suspicion as described in § 219.300, the following...

  14. Messenger RNA biomarker signatures for forensic body fluid identification revealed by targeted RNA sequencing.

    PubMed

    Hanson, E; Ingold, S; Haas, C; Ballantyne, J

    2018-05-01

    The recovery of a DNA profile from the perpetrator or victim in criminal investigations can provide valuable 'source level' information for investigators. However, a DNA profile does not reveal the circumstances by which biological material was transferred. Some contextual information can be obtained by a determination of the tissue or fluid source of origin of the biological material as it is potentially indicative of some behavioral activity on behalf of the individual that resulted in its transfer from the body. Here, we sought to improve upon established RNA based methods for body fluid identification by developing a targeted multiplexed next generation mRNA sequencing assay comprising a panel of approximately equal sized gene amplicons. The multiplexed biomarker panel includes several highly specific gene targets with the necessary specificity to definitively identify most forensically relevant biological fluids and tissues (blood, semen, saliva, vaginal secretions, menstrual blood and skin). In developing the biomarker panel we evaluated 66 gene targets, with a progressive iteration of testing target combinations that exhibited optimal sensitivity and specificity using a training set of forensically relevant body fluid samples. The current assay comprises 33 targets: 6 blood, 6 semen, 6 saliva, 4 vaginal secretions, 5 menstrual blood and 6 skin markers. We demonstrate the sensitivity and specificity of the assay and the ability to identify body fluids in single source and admixed stains. A 16 sample blind test was carried out by one lab with samples provided by the other participating lab. The blinded lab correctly identified the body fluids present in 15 of the samples with the major component identified in the 16th. Various classification methods are being investigated to permit inference of the body fluid/tissue in dried physiological stains. These include the percentage of reads in a sample that are due to each of the 6 tissues/body fluids tested and inter-sample differential gene expression revealed by agglomerative hierarchical clustering. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Fluorescent adduct formation with terbium: a novel strategy for transferrin glycoform identification in human body fluids and carbohydrate-deficient transferrin HPLC method validation.

    PubMed

    Sorio, Daniela; De Palo, Elio Franco; Bertaso, Anna; Bortolotti, Federica; Tagliaro, Franco

    2017-02-01

    This paper puts forward a new method for the transferrin (Tf) glycoform analysis in body fluids that involves the formation of a transferrin-terbium fluorescent adduct (TfFluo). The key idea is to validate the analytical procedure for carbohydrate-deficient transferrin (CDT), a traditional biochemical serum marker to identify chronic alcohol abuse. Terbium added to a human body-fluid sample produced TfFluo. Anion exchange HPLC technique, with fluorescence detection (λ exc 298 nm and λ em 550 nm), permitted clear separation and identification of Tf glycoform peaks without any interfering signals, allowing selective Tf sialoforms analysis in human serum and body fluids (cadaveric blood, cerebrospinal fluid, and dried blood spots) hampered for routine test. Serum samples (n = 78) were analyzed by both traditional absorbance (Abs) and fluorescence (Fl) HPLC methods and CDT% levels demonstrated a significant correlation (p < 0.001 Pearson). Intra- and inter-runs CV% was 3.1 and 4.6%, respectively. The cut-off of 1.9 CDT%, related to the HPLC Abs proposed as the reference method, by interpolation in the correlation curve with the present method demonstrated a 1.3 CDT% cut-off. Method comparison by Passing-Bablok and Bland-Altman tests demonstrated Fl versus Abs agreement. In conclusion, the novel method is a reliable test for CDT% analysis and provides a substantial analytical improvement offering important advantages in terms of types of body fluid analysis. Its sensitivity and absence of interferences extend clinical applications being reliable for CDT assay on body fluids usually not suitable for routine test. Graphical Abstract The formation of a transferrin-terbium fluorescent adduct can be used to analyze the transferrin glycoforms. The HPLC method for carbohydrate-deficient transferrin (CDT%) measurement was validated and employed to determine the levels in different body fluids.

  16. Analysis of body fluids for forensic purposes: from laboratory testing to non-destructive rapid confirmatory identification at a crime scene.

    PubMed

    Virkler, Kelly; Lednev, Igor K

    2009-07-01

    Body fluid traces recovered at crime scenes are among the most important types of evidence to forensic investigators. They contain valuable DNA evidence which can identify a suspect or victim as well as exonerate an innocent individual. The first step of identifying a particular body fluid is highly important since the nature of the fluid is itself very informative to the investigation, and the destructive nature of a screening test must be considered when only a small amount of material is available. The ability to characterize an unknown stain at the scene of the crime without having to wait for results from a laboratory is another very critical step in the development of forensic body fluid analysis. Driven by the importance for forensic applications, body fluid identification methods have been extensively developed in recent years. The systematic analysis of these new developments is vital for forensic investigators to be continuously educated on possible superior techniques. Significant advances in laser technology and the development of novel light detectors have dramatically improved spectroscopic methods for molecular characterization over the last decade. The application of this novel biospectroscopy for forensic purposes opens new and exciting opportunities for the development of on-field, non-destructive, confirmatory methods for body fluid identification at a crime scene. In addition, the biospectroscopy methods are universally applicable to all body fluids unlike the majority of current techniques which are valid for individual fluids only. This article analyzes the current methods being used to identify body fluid stains including blood, semen, saliva, vaginal fluid, urine, and sweat, and also focuses on new techniques that have been developed in the last 5-6 years. In addition, the potential of new biospectroscopic techniques based on Raman and fluorescence spectroscopy is evaluated for rapid, confirmatory, non-destructive identification of a body fluid at a crime scene.

  17. Development of risk reduction behavioral counseling for Ebola virus disease survivors enrolled in the Sierra Leone Ebola Virus Persistence Study, 2015-2016.

    PubMed

    Abad, Neetu; Malik, Tasneem; Ariyarajah, Archchun; Ongpin, Patricia; Hogben, Matthew; McDonald, Suzanna L R; Marrinan, Jaclyn; Massaquoi, Thomas; Thorson, Anna; Ervin, Elizabeth; Bernstein, Kyle; Ross, Christine; Liu, William J; Kroeger, Karen; Durski, Kara N; Broutet, Nathalie; Knust, Barbara; Deen, Gibrilla F

    2017-09-01

    During the 2014-2016 West Africa Ebola Virus Disease (EVD) epidemic, the public health community had concerns that sexual transmission of the Ebola virus (EBOV) from EVD survivors was a risk, due to EBOV persistence in body fluids of EVD survivors, particularly semen. The Sierra Leone Ebola Virus Persistence Study was initiated to investigate this risk by assessing EBOV persistence in numerous body fluids of EVD survivors and providing risk reduction counseling based on test results for semen, vaginal fluid, menstrual blood, urine, rectal fluid, sweat, tears, saliva, and breast milk. This publication describes implementation of the counseling protocol and the key lessons learned. The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol was developed from a framework used to prevent transmission of HIV and other sexually transmitted infections. The framework helped to identify barriers to risk reduction and facilitated the development of a personalized risk-reduction plan, particularly around condom use and abstinence. Pre-test and post-test counseling sessions included risk reduction guidance, and post-test counseling was based on the participants' individual test results. The behavioral counseling protocol enabled study staff to translate the study's body fluid test results into individualized information for study participants. The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol provided guidance to mitigate the risk of EBOV transmission from EVD survivors. It has since been shared with and adapted by other EVD survivor body fluid testing programs and studies in Ebola-affected countries.

  18. Body mass changes during training in elite rugby union: Is a single test of hydration indices reliable?

    PubMed

    Black, Katherine Elizabeth; Black, Alistair David; Baker, Dane; Fairbairn, Kirsty

    2018-05-28

    There is limited research studying fluid and electrolyte balance in rugby union players, and a paucity of information regarding the test-retest reliability. This study describes the fluid balance of elite rugby union players across multiple squads and the reliability of fluid balance measures between two equivalent training sessions. Sixty-one elite rugby players completed a single fluid balance testing session during a game simulation training session. A subsample of 21 players completed a second fluid balance testing session during an equivalent training session. Players were weighed in minimal clothing before and after each training session. Each player was provided with their own drinks which were weighed before and after each training session. More players gained body weight (9 (14.8%)) during training than lost greater than 2% of their initial body mass (1 (1.6%)). Pre-training body mass and rate of fluid loss were significantly associated (r = 0.318, p = .013). There was a significant correlation between rate of fluid loss in sessions 1 (1.74 ± 0.32 L h -1 ) and 2 (1.10 ± 0.31 L. h -1 ), (r = 0.470, p = .032). This could be useful for nutritionists working with rugby squads to identify players with high sweat losses.

  19. Environmental Stability and Infectivity of Hepatitis C Virus (HCV) in Different Human Body Fluids.

    PubMed

    Pfaender, Stephanie; Helfritz, Fabian A; Siddharta, Anindya; Todt, Daniel; Behrendt, Patrick; Heyden, Julia; Riebesehl, Nina; Willmann, Wiebke; Steinmann, Joerg; Münch, Jan; Ciesek, Sandra; Steinmann, Eike

    2018-01-01

    Background: Hepatitis C virus (HCV) is a hepatotropic, blood-borne virus, but in up to one-third of infections of the transmission route remained unidentified. Viral genome copies of HCV have been identified in several body fluids, however, non-parental transmission upon exposure to contaminated body fluids seems to be rare. Several body fluids, e.g., tears and saliva, are renowned for their antimicrobial and antiviral properties, nevertheless, HCV stability has never been systematically analyzed in those fluids. Methods: We used state of the art infectious HCV cell culture techniques to investigate the stability of HCV in different body fluids to estimate the potential risk of transmission via patient body fluid material. In addition, we mimicked a potential contamination of HCV in tear fluid and analyzed which impact commercially available contact lens solutions might have in such a scenario. Results: We could demonstrate that HCV remains infectious over several days in body fluids like tears, saliva, semen, and cerebrospinal fluid. Only hydrogen-peroxide contact lens solutions were able to efficiently inactivate HCV in a suspension test. Conclusion: These results indicate that HCV, once it is present in various body fluids of infected patients, remains infective and could potentially contribute to transmission upon direct contact.

  20. Apparatus enables automatic microanalysis of body fluids

    NASA Technical Reports Server (NTRS)

    Soffen, G. A.; Stuart, J. L.

    1966-01-01

    Apparatus will automatically and quantitatively determine body fluid constituents which are amenable to analysis by fluorometry or colorimetry. The results of the tests are displayed as percentages of full scale deflection on a strip-chart recorder. The apparatus can also be adapted for microanalysis of various other fluids.

  1. Development of risk reduction behavioral counseling for Ebola virus disease survivors enrolled in the Sierra Leone Ebola Virus Persistence Study, 2015-2016

    PubMed Central

    Malik, Tasneem; Ariyarajah, Archchun; Ongpin, Patricia; Hogben, Matthew; McDonald, Suzanna L. R.; Marrinan, Jaclyn; Massaquoi, Thomas; Thorson, Anna; Ervin, Elizabeth; Bernstein, Kyle; Ross, Christine; Liu, William J.; Kroeger, Karen; Durski, Kara N.; Broutet, Nathalie; Knust, Barbara; Deen, Gibrilla F.

    2017-01-01

    Background During the 2014–2016 West Africa Ebola Virus Disease (EVD) epidemic, the public health community had concerns that sexual transmission of the Ebola virus (EBOV) from EVD survivors was a risk, due to EBOV persistence in body fluids of EVD survivors, particularly semen. The Sierra Leone Ebola Virus Persistence Study was initiated to investigate this risk by assessing EBOV persistence in numerous body fluids of EVD survivors and providing risk reduction counseling based on test results for semen, vaginal fluid, menstrual blood, urine, rectal fluid, sweat, tears, saliva, and breast milk. This publication describes implementation of the counseling protocol and the key lessons learned. Methodology/Principal findings The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol was developed from a framework used to prevent transmission of HIV and other sexually transmitted infections. The framework helped to identify barriers to risk reduction and facilitated the development of a personalized risk-reduction plan, particularly around condom use and abstinence. Pre-test and post-test counseling sessions included risk reduction guidance, and post-test counseling was based on the participants’ individual test results. The behavioral counseling protocol enabled study staff to translate the study’s body fluid test results into individualized information for study participants. Conclusions/Significance The Ebola Virus Persistence Risk Reduction Behavioral Counseling Protocol provided guidance to mitigate the risk of EBOV transmission from EVD survivors. It has since been shared with and adapted by other EVD survivor body fluid testing programs and studies in Ebola-affected countries. PMID:28892490

  2. Screening and confirmation of microRNA markers for forensic body fluid identification.

    PubMed

    Wang, Zheng; Zhang, Ji; Luo, Haibo; Ye, Yi; Yan, Jing; Hou, Yiping

    2013-01-01

    MicroRNAs (miRNAs, ∼22 nucleotides) are small, non-protein coding RNAs that regulate gene expression at the post-transcriptional level. MiRNAs can express in a tissue-specific manner, and have been introduced to forensic body fluid identification. In this study, we employed the qPCR-array (TaqMan(®) Array Human MicroRNA Cards) to screen the body fluid-specific miRNAs. Seven candidate miRNAs were identified as potentially body fluid-specific and could be used as forensically relevant body fluid markers: miR16 and miR486 for venous blood, miR888 and miR891a for semen, miR214 for menstrual blood, miR124a for vaginal secretions, and miR138-2 for saliva. The candidate miRNA markers were then validated via hydrolysis probes quantitative real-time polymerase chain reaction (TaqMan-qPCR). In addition, BestKeeper software was used to validate the expression stability of four genes, RNU44, RNU48, U6 and U6b, regularly used as reference genes (RGs) for studies involving forensic body fluids. The current study suggests that U6 could be used as a proper RG of miRNAs in forensic body fluid identification. The relative expression ratios (R) of miR486, miR888, miR214, miR16 and miR891a can differentiate the target body fluid from other body fluids that were tested in this study. The detection limit of TaqMan-qPCR of the five confirmed miRNA markers was 10pg of total RNA. The effect of time-wise degradation of blood stains and semen stains for 1 month under normal laboratory conditions was tested and did not significantly affect the detection results. Herein, this study proposes five body fluid-specific miRNAs for the forensic identification of venous blood, semen, and menstrual blood, of which miR486, miR888, and miR214 may be used as new markers for body fluid identification. Additional work remains necessary in search for suitable miRNA markers and stable RGs for forensic body fluid identification. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  3. ICSH guidelines for the verification and performance of automated cell counters for body fluids.

    PubMed

    Bourner, G; De la Salle, B; George, T; Tabe, Y; Baum, H; Culp, N; Keng, T B

    2014-12-01

    One of the many challenges facing laboratories is the verification of their automated Complete Blood Count cell counters for the enumeration of body fluids. These analyzers offer improved accuracy, precision, and efficiency in performing the enumeration of cells compared with manual methods. A patterns of practice survey was distributed to laboratories that participate in proficiency testing in Ontario, Canada, the United States, the United Kingdom, and Japan to determine the number of laboratories that are testing body fluids on automated analyzers and the performance specifications that were performed. Based on the results of this questionnaire, an International Working Group for the Verification and Performance of Automated Cell Counters for Body Fluids was formed by the International Council for Standardization in Hematology (ICSH) to prepare a set of guidelines to help laboratories plan and execute the verification of their automated cell counters to provide accurate and reliable results for automated body fluid counts. These guidelines were discussed at the ICSH General Assemblies and reviewed by an international panel of experts to achieve further consensus. © 2014 John Wiley & Sons Ltd.

  4. Labyrinth and cerebral-spinal fluid pressure changes in guinea pigs and monkeys during simulated zero G

    NASA Technical Reports Server (NTRS)

    Parker, D. E.

    1977-01-01

    This study was undertaken to explore the hypothesis that shifts of body fluids from the legs and torso toward the head contribute to the motion sickness experienced by astronauts and cosmonauts. The shifts in body fluids observed during zero-G exposure were simulated by elevating guinea pigs' and monkeys' torsos and hindquarters. Cerebral-spinal fluid pressure was recorded from a transducer located in a brain ventricle; labyrinth fluid pressure was recorded from a pipette cemented in a hole in a semicircular canal. An anticipated divergence in cerebral-spinal fluid pressure and labyrinth fluid pressure during torso elevation was not observed. The results of this study do not support a fluid shift mechanism of zero-G-induced motion sickness. However, a more complete test of the fluid shift mechanism would be obtained if endolymph and perilymph pressure changes were determined separately; we have been unable to perform this test to date.

  5. The detection and discrimination of human body fluids using ATR FT-IR spectroscopy.

    PubMed

    Orphanou, Charlotte-Maria; Walton-Williams, Laura; Mountain, Harry; Cassella, John

    2015-07-01

    Blood, saliva, semen and vaginal secretions are the main human body fluids encountered at crime scenes. Currently presumptive tests are routinely utilised to indicate the presence of body fluids, although these are often subject to false positives and limited to particular body fluids. Over the last decade more sensitive and specific body fluid identification methods have been explored, such as mRNA analysis and proteomics, although these are not yet appropriate for routine application. This research investigated the application of ATR FT-IR spectroscopy for the detection and discrimination of human blood, saliva, semen and vaginal secretions. The results demonstrated that ATR FT-IR spectroscopy can detect and distinguish between these body fluids based on the unique spectral pattern, combination of peaks and peak frequencies corresponding to the macromolecule groups common within biological material. Comparisons with known abundant proteins relevant to each body fluid were also analysed to enable specific peaks to be attributed to the relevant protein components, which further reinforced the discrimination and identification of each body fluid. Overall, this preliminary research has demonstrated the potential for ATR FT-IR spectroscopy to be utilised in the routine confirmatory screening of biological evidence due to its quick and robust application within forensic science. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Thermophysiological responses caused by ballistic bullet-proof vests.

    PubMed

    Lehmacher, E J; Jansing, P; Küpper, T

    2007-01-01

    Little data is available concerning the heat stress experienced by members of staff who wear bullet-proof vests in a warm or hot environment. For this reason, knowledge is limited and, consequently, preventative advice on how to avoid heat sickness or hyperthermia is required. Skin and body temperatures, fluid loss and the heart rate of 30 persons (15 test persons versus 15 control persons) were measured in three situations typical of the test participants' job situations. Environmental data (wind velocity, air humidity, air temperature) were measured during the tests as well. Whereas there was a significant increase in skin temperatures, there was no difference in the core body temperatures of both groups. Maximum core body temperature remained well below 38 degrees C in all subjects. Test persons wearing vests showed a fluid loss of 1.1 l on average (non-vest wearers in the control group 1.0 l). There is no increased risk of heat stroke or hyperthermia for employees wearing bullet-proof vests in comparison with employees who do not wear them. Both groups, however, should be advised to ensure an adequate intake of fluid to maintain a healthy body fluid balance when working in hot environments.

  7. A collaborative exercise on DNA methylation based body fluid typing.

    PubMed

    Jung, Sang-Eun; Cho, Sohee; Antunes, Joana; Gomes, Iva; Uchimoto, Mari L; Oh, Yu Na; Di Giacomo, Lisa; Schneider, Peter M; Park, Min Sun; van der Meer, Dieudonne; Williams, Graham; McCord, Bruce; Ahn, Hee-Jung; Choi, Dong Ho; Lee, Yang Han; Lee, Soong Deok; Lee, Hwan Young

    2016-10-01

    A collaborative exercise on DNA methylation based body fluid identification was conducted by seven laboratories. For this project, a multiplex methylation SNaPshot reaction composed of seven CpG markers was used for the identification of four body fluids, including blood, saliva, semen, and vaginal fluid. A total of 30 specimens were prepared and distributed to participating laboratories after thorough testing. The required experiments included four increasingly complex tasks: (1) CE of a purified single-base extension reaction product, (2) multiplex PCR and multiplex single-base extension reaction of bisulfite-modified DNA, (3) bisulfite conversion of genomic DNA, and (4) extraction of genomic DNA from body fluid samples. In tasks 2, 3 and 4, one or more mixtures were analyzed, and specimens containing both known and unknown body fluid sources were used. Six of the laboratories generated consistent body fluid typing results for specimens of bisulfite-converted DNA and genomic DNA. One laboratory failed to set up appropriate conditions for capillary analysis of reference single-base extension products. In general, variation in the values obtained for DNA methylation analysis between laboratories increased with the complexity of the required experiments. However, all laboratories concurred on the interpretation of the DNA methylation profiles produced. Although the establishment of interpretational guidelines on DNA methylation based body fluid identification has yet to be performed, this study supports the addition of DNA methylation profiling to forensic body fluid typing. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Bioimpedance Spectroscopy for Assessment of Volume Status in Patients before and after General Anaesthesia

    PubMed Central

    Ernstbrunner, Matthäus; Kostner, Lisa; Kimberger, Oliver; Wabel, Peter; Säemann, Marcus; Markstaller, Klaus; Fleischmann, Edith; Kabon, Barbara; Hecking, Manfred

    2014-01-01

    Background Technically assisted assessment of volume status before surgery may be useful to direct intraoperative fluid administration. We therefore tested a recently developed whole-body bioimpedance spectroscopy device to determine pre- to postoperative fluid distribution. Methods Using a three-compartment physiologic tissue model, the body composition monitor (BCM, Fresenius Medical Care, Germany) measures total body fluid volume, extracellular volume, intracellular volume and fluid overload as surplus or deficit of ‘normal’ extracellular volume. BCM-measurements were performed before and after standardized general anaesthesia for gynaecological procedures (laparotomies, laparoscopies and vaginal surgeries). BCM results were blinded to the attending anaesthesiologist and data analysed using the 2-sided, paired Student’s t-test and multiple linear regression. Results In 71 females aged 45±15 years with body weight 67±13 kg and duration of anaesthesia 154±68 min, pre- to postoperative fluid overload increased from −0.7±1.1 L to 0.1±1.0 L, corresponding to −5.1±7.5% and 0.8±6.7% of normal extracellular volume, respectively (both p<0.001), after patients had received 1.9±0.9 L intravenous crystalloid fluid. Perioperative urinary excretion was 0.4±0.3 L. The increase in extracellular volume was paralleled by an increase in total body fluid volume, while intracellular volume increased only slightly and without reaching statistical significance (p = 0.15). Net perioperative fluid balance (administered fluid volume minus urinary excretion) was significantly associated with change in extracellular volume (r2 = 0.65), but was not associated with change in intracellular volume (r2 = 0.01). Conclusions Routine intraoperative fluid administration results in a significant, and clinically meaningful increase in the extracellular compartment. BCM-measurements yielded plausible results and may become useful to guide intraoperative fluid therapy in future studies. PMID:25360698

  9. Cold-water acclimation does not modify whole-body fluid regulation during subsequent cold-water immersion.

    PubMed

    Stocks, J M; Patterson, M J; Hyde, D E; Jenkins, A B; Mittleman, K D; Taylor, N A S

    2004-06-01

    We investigated the impact of cold-water acclimation on whole-body fluid regulation using tracer-dilution methods to differentiate between the intracellular and extracellular fluid compartments. Seven euhydrated males [age 24.7 (8.7) years, mass 74.4 (6.4) kg, height 176.8 (7.8) cm, sum of eight skinfolds 107.4 (20.4) mm; mean (SD)] participated in a 14-day cold-water acclimation protocol, with 60-min resting cold-water stress tests [CWST; 18.1 (0.1) degrees C] on days 1, 8 and 15, and 90-min resting cold-water immersions [18.4 (0.4) degrees C] on intervening days. Subjects were immersed to the 4th intercostal space. Intracellular and extracellular fluid compartments, and plasma protein, electrolyte and hormone concentrations were investigated. During the first CWST, the intracellular fluid (5.5%) and plasma volumes were reduced (6.1%), while the interstitial fluid volume was simultaneously expanded (5.4%). This pattern was replicated on days 8 and 15, but did not differ significantly among test days. Acclimation did not produce significant changes in the pre-immersion distribution of total body water, or changes in plasma osmolality, total protein, electrolyte, atrial natriuretic peptide or aldosterone concentrations. Furthermore, a 14-day cold-water acclimation regimen did not elicit significant changes in body-fluid distribution, urine production, or the concentrations of plasma protein, electrolytes or the fluid-regulatory hormones. While acclimation trends were not evident, we have confirmed that fluid from extravascular cells is displaced into the interstitium during acute cold-water immersion, both before and after cold acclimation.

  10. Body Fluid Regulation and Hemopoiesis in Space Flight

    NASA Technical Reports Server (NTRS)

    1997-01-01

    In this session, Session JA2, the discussion focuses on the following topics: Bodymass and Fluid Distribution During Longterm Spaceflight with and without Countermeasures; Plasma Volume, Extracellular Fluid Volume, and Regulatory Hormones During Long-Term Space Flight; Effect of Microgravity and its Ground-Based Models on Fluid Volumes and Hemocirculatory Volumes; Seventeen Weeks of Horizontal Bed Rest, Lower Body Negative Pressure Testing, and the Associated Plasma Volume Response; Evaporative Waterloss in Space Theoretical and Experimental Studies; Erythropoietin Under Real and Simulated Micro-G Conditions in Humans; and Vertebral Bone Marrow Changes Following Space Flight.

  11. DNA methylation profiling for a confirmatory test for blood, saliva, semen, vaginal fluid and menstrual blood.

    PubMed

    Lee, Hwan Young; Jung, Sang-Eun; Lee, Eun Hee; Yang, Woo Ick; Shin, Kyoung-Jin

    2016-09-01

    The ability to predict the type of tissues or cells from molecular profiles of crime scene samples has important practical implications in forensics. A previously reported multiplex assay using DNA methylation markers could only discriminate between 4 types of body fluids: blood, saliva, semen, and the body fluid which originates from female reproductive organ. In the present study, we selected 15 menstrual blood-specific CpG marker candidates based on analysis of 12 genome-wide DNA methylation profiles of vaginal fluid and menstrual blood. The menstrual blood-specificity of the candidate markers was confirmed by comparison with HumanMethylation450 BeadChip array data obtained for 58 samples including 12 blood, 12 saliva, 12 semen, 3 vaginal fluid, and 19 skin epidermis samples. Among 15CpG marker candidates, 3 were located in the promoter region of the SLC26A10 gene, and 2 of them (cg09696411 and cg18069290) showed high menstrual blood specificity. DNA methylation at the 2CpG markers was further tested by targeted bisulfite sequencing of 461 additional samples including 49 blood, 52 saliva, 34 semen, 125 vaginal fluid, and 201 menstrual blood. Because the 2 markers showed menstrual blood-specific methylation patterns, we modified our previous multiplex methylation SNaPshot reaction to include these 2 markers. In addition, a blood marker cg01543184 with cross reactivity to semen was replaced with cg08792630, and a semen-specific unmethylation marker cg17621389 was removed. The resultant multiplex methylation SNaPshot allowed positive identification of blood, saliva, semen, vaginal fluid and menstrual blood using the 9CpG markers which show a methylation signal only in the target body fluids. Because of the complexity in cell composition, menstrual bloods produced DNA methylation profiles that vary with menstrual cycle and sample collection methods, which are expected to provide more insight into forensic menstrual blood test. Moreover, because the developed multiplex methylation SNaPshot reaction includes the 4CpG markers of which specificities have been confirmed by multiple studies, it will facilitate confirmatory tests for body fluids that are frequently observed in forensic casework. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  12. MicroRNA markers for forensic body fluid identification obtained from microarray screening and quantitative RT-PCR confirmation

    PubMed Central

    Zubakov, Dmitry; Boersma, Anton W. M.; Choi, Ying; van Kuijk, Patricia F.; Wiemer, Erik A. C.

    2010-01-01

    MicroRNAs (miRNAs) are non-protein coding molecules with important regulatory functions; many have tissue-specific expression patterns. Their very small size in principle makes them less prone to degradation processes, unlike messenger RNAs (mRNAs), which were previously proposed as molecular tools for forensic body fluid identification. To identify suitable miRNA markers for forensic body fluid identification, we first screened total RNA samples derived from saliva, semen, vaginal secretion, and venous and menstrual blood for the expression of 718 human miRNAs using a microarray platform. All body fluids could be easily distinguished from each other on the basis of complete array-based miRNA expression profiles. Results from quantitative reverse transcription PCR (RT-PCR; TaqMan) assays for microarray candidate markers confirmed strong over-expression in the targeting body fluid of several miRNAs for venous blood and several others for semen. However, no candidate markers from array experiments for other body fluids such as saliva, vaginal secretion, or menstrual blood could be confirmed by RT-PCR. Time-wise degradation of venous blood and semen stains for at least 1 year under lab conditions did not significantly affect the detection sensitivity of the identified miRNA markers. The detection limit of the TaqMan assays tested for selected venous blood and semen miRNA markers required only subpicogram amounts of total RNA per single RT-PCR test, which is considerably less than usually needed for reliable mRNA RT-PCR detection. We therefore propose the application of several stable miRNA markers for the forensic identification of blood stains and several others for semen stain identification, using commercially available TaqMan assays. Additional work remains necessary in search for suitable miRNA markers for other forensically relevant body fluids. Electronic supplementary material The online version of this article (doi:10.1007/s00414-009-0402-3) contains supplementary material, which is available to authorized users. PMID:20145944

  13. Characterization of 17-4 PH stainless steel foam for biomedical applications in simulated body fluid and artificial saliva environments.

    PubMed

    Mutlu, Ilven; Oktay, Enver

    2013-04-01

    Highly porous 17-4 PH stainless steel foam for biomedical applications was produced by space holder technique. Metal release and weight loss from 17-4 PH stainless steel foams was investigated in simulated body fluid and artificial saliva environments by static immersion tests. Inductively coupled plasma-mass spectrometer was employed to measure the concentrations of various metal ions released from the 17-4 PH stainless steel foams into simulated body fluids and artificial saliva. Effect of immersion time and pH value on metal release and weight loss in simulated body fluid and artificial saliva were determined. Pore morphology, pore size and mechanical properties of the 17-4 PH stainless steel foams were close to human cancellous bone. Copyright © 2012 Elsevier B.V. All rights reserved.

  14. High resolution melt curve analysis based on methylation status for human semen identification.

    PubMed

    Fachet, Caitlyn; Quarino, Lawrence; Karnas, K Joy

    2017-03-01

    A high resolution melt curve assay to differentiate semen from blood, saliva, urine, and vaginal fluid based on methylation status at the Dapper Isoform 1 (DACT1) gene was developed. Stains made from blood, saliva, urine, semen, and vaginal fluid were obtained from volunteers and DNA was isolated using either organic extraction (saliva, urine, and vaginal fluid) or Chelex ® 100 extraction (blood and semen). Extracts were then subjected to bisulfite modification in order to convert unmethylated cytosines to uracil, consequently creating sequences whose amplicons have melt curves that vary depending on their initial methylation status. When primers designed to amplify the promoter region of the DACT1 gene were used, DNA from semen samples was distinguishable from other fluids by a having a statistically significant lower melting temperature. The assay was found to be sperm-significant since semen from a vasectomized man produced a melting temperature similar to the non-semen body fluids. Blood and semen stains stored up to 5 months and tested at various intervals showed little variation in melt temperature indicating the methylation status was stable during the course of the study. The assay is a more viable method for forensic science practice than most molecular-based methods for body fluid stain identification since it is time efficient and utilizes instrumentation common to forensic biology laboratories. In addition, the assay is advantageous over traditional presumptive chemical methods for body fluid identification since results are confirmatory and the assay offers the possibility of multiplexing which may test for multiple body fluids simultaneously.

  15. NASA/MSFC's Calculation for Test Case 1a of ATAC-FSDC Workshop on After-body and Nozzle Flows

    NASA Technical Reports Server (NTRS)

    Ruf, Joseph H.

    2006-01-01

    Mr. Ruf of NASA/MSFC executed the CHEM computational fluid dynamics (CFD) code to provide a prediction of the test case 1 a for the ATAC-FSDC Workshop on After-body and Nozzle Flows. CHEM is used extensively at MSFC for a wide variety of fluid dynamic problems. These problems include; injector element flows, nozzle flows, feed line flows, turbomachinery flows, solid rocket motor internal flows, plume vehicle flow interactions, etc.

  16. Correlations between Different Heavy Metals in Diverse Body Fluids: Studies of Human Semen Quality

    PubMed Central

    Mínguez-Alarcón, Lidia; Mendiola, Jaime; Roca, Manuela; López-Espín, José J.; Guillén, José J.; Moreno, José M.; Moreno-Grau, Stella; Martínez-García, María J.; Vergara-Juárez, Nuria; Elvira-Rendueles, Belén; García-Sánchez, Antonio; Ten, Jorge; Bernabeu, Rafael; Torres-Cantero, Alberto M.

    2012-01-01

    It has been hypothesized that exposure to heavy metals may impair male reproduction. To measure the effect produced by low doses of heavy metals on semen parameters, it is necessary to clarify in which body fluids those measurements must be performed. Sixty-one men attending infertility clinics participated in our study. Concentrations of lead, cadmium, and mercury were measured in whole blood, blood plasma, and seminal plasma using spectroanalytical and electrochemical methods. Semen analyses were performed according to World Health Organization criteria. For statistical analysis, Spearman's rank correlations, mean comparison tests, and discriminant analysis were calculated. Significant correlations between the measured concentrations of the three heavy metals in the same biological fluids were observed. However, no similar relationship was seen when comparing the concentrations in different body fluids of the same metal. According to our results and previous publications, seminal plasma might be the best body fluid for assessing impairment of human semen parameters. PMID:22312326

  17. Aldosterone and Renin Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... must be careful to maintain fluid and electrolyte balance. Kidney failure is a possible complication of Bartter ...

  18. Fecal electrolyte testing for evaluation of unexplained diarrhea: Validation of body fluid test accuracy in the absence of a reference method.

    PubMed

    Voskoboev, Nikolay V; Cambern, Sarah J; Hanley, Matthew M; Giesen, Callen D; Schilling, Jason J; Jannetto, Paul J; Lieske, John C; Block, Darci R

    2015-11-01

    Validation of tests performed on body fluids other than blood or urine can be challenging due to the lack of a reference method to confirm accuracy. The aim of this study was to evaluate alternate assessments of accuracy that laboratories can rely on to validate body fluid tests in the absence of a reference method using the example of sodium (Na(+)), potassium (K(+)), and magnesium (Mg(2+)) testing in stool fluid. Validations of fecal Na(+), K(+), and Mg(2+) were performed on the Roche cobas 6000 c501 (Roche Diagnostics) using residual stool specimens submitted for clinical testing. Spiked recovery, mixing studies, and serial dilutions were performed and % recovery of each analyte was calculated to assess accuracy. Results were confirmed by comparison to a reference method (ICP-OES, PerkinElmer). Mean recoveries for fecal electrolytes were Na(+) upon spiking=92%, mixing=104%, and dilution=105%; K(+) upon spiking=94%, mixing=96%, and dilution=100%; and Mg(2+) upon spiking=93%, mixing=98%, and dilution=100%. When autoanalyzer results were compared to reference ICP-OES results, Na(+) had a slope=0.94, intercept=4.1, and R(2)=0.99; K(+) had a slope=0.99, intercept=0.7, and R(2)=0.99; and Mg(2+) had a slope=0.91, intercept=-4.6, and R(2)=0.91. Calculated osmotic gap using both methods were highly correlated with slope=0.95, intercept=4.5, and R(2)=0.97. Acid pretreatment increased magnesium recovery from a subset of clinical specimens. A combination of mixing, spiking, and dilution recovery experiments are an acceptable surrogate for assessing accuracy in body fluid validations in the absence of a reference method. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  19. The Toxicological Geochemistry of Dusts, Soils, and Other Earth Materials: Insights From In Vitro Physiologically-based Geochemical Leach Tests

    NASA Astrophysics Data System (ADS)

    Plumlee, G. S.; Ziegler, T. L.; Lamothe, P.; Meeker, G. P.; Sutley, S.

    2003-12-01

    Exposure to mineral dusts, soils, and other earth materials results in chemical reactions between the materials and different body fluids that include, depending upon the exposure route, lung fluids, gastrointestinal fluids, and perspiration. In vitro physiologically-based geochemical leach tests provide useful insights into these chemical reactions and their potential toxicological implications. We have conducted such leach tests on a variety of earth materials, including asbestos, volcanic ash, dusts from dry lake beds, mine wastes, wastes left from the roasting of mercury ores, mineral processing wastes, coal dusts and coal fly ash, various soils, and complex dusts generated by the World Trade Center collapse. Size-fractionated samples of earth materials that have been well-characterized mineralogically and chemically are reacted at body temperature (37 C) for periods from 2 hours up to multiple days with various proportions of simulated lung, gastric, intestinal, and/or plasma-based fluids. Results indicate that different earth materials may have quite different solubility and dissolution behavior in vivo, depending upon a) the mineralogic makeup of the material, and b) the exposure route. For example, biodurable minerals such as asbestos and volcanic ash particles, whose health effects result because they dissolve very slowly in vivo, bleed off low levels of trace metals into the simulated lung fluids; these include metals such as Fe and Cr that are suspected by health scientists of contributing to the generation of reactive oxygen species and resulting DNA damage in vivo. In contrast, dry lake bed dusts and concrete-rich dusts are highly alkaline and bioreactive, and cause substantial pH increases and other chemical changes in the simulated body fluids. Many of the earth materials tested contain a variety of metals that can be quite soluble (bioaccessible), depending upon the material and the simulated body fluid composition. For example, due to their acidic pH and high chloride concentrations, simulated gastric fluids are most efficient at solubilizing metals such as Hg, Pb, Zn, and others that form strong chloride complexes; although these metals tend to partially reprecipitate in the near-neutral simulated intestinal fluids, complexes with organic ligands (i.e., amino and carboxylic acids) enhance their solubility. These metals are also quite soluble in near-neutral, protein-rich plasma-based fluids because they form strong complexes with the proteins. In contrast, metalloids that form oxyanion species (such as As, Cr, Mo, W) are commonly more soluble in near-neutral pH simulated lung fluids than in simulated gastric fluids.

  20. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    PubMed

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-10-15

    We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF's test reports. Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety.

  1. Beta-2 Microglobulin Kidney Disease Test

    MedlinePlus

    ... Tumor Marker AMAS Aminoglycoside Antibiotics Ammonia Amniotic Fluid Analysis Amylase ANCA/MPO/PR3 Antibodies Androstenedione Angiotensin-Converting ... Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis Bone Markers Bone Marrow Aspiration and Biopsy BRCA ...

  2. Prediction of Body Fluids where Proteins are Secreted into Based on Protein Interaction Network

    PubMed Central

    Hu, Le-Le; Huang, Tao; Cai, Yu-Dong; Chou, Kuo-Chen

    2011-01-01

    Determining the body fluids where secreted proteins can be secreted into is important for protein function annotation and disease biomarker discovery. In this study, we developed a network-based method to predict which kind of body fluids human proteins can be secreted into. For a newly constructed benchmark dataset that consists of 529 human-secreted proteins, the prediction accuracy for the most possible body fluid location predicted by our method via the jackknife test was 79.02%, significantly higher than the success rate by a random guess (29.36%). The likelihood that the predicted body fluids of the first four orders contain all the true body fluids where the proteins can be secreted into is 62.94%. Our method was further demonstrated with two independent datasets: one contains 57 proteins that can be secreted into blood; while the other contains 61 proteins that can be secreted into plasma/serum and were possible biomarkers associated with various cancers. For the 57 proteins in first dataset, 55 were correctly predicted as blood-secrete proteins. For the 61 proteins in the second dataset, 58 were predicted to be most possible in plasma/serum. These encouraging results indicate that the network-based prediction method is quite promising. It is anticipated that the method will benefit the relevant areas for both basic research and drug development. PMID:21829572

  3. Physiologic mechanisms of circulatory and body fluid losses in weightlessness identified by mathematical modeling

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Srinivasan, R. S.; Charles, J. B.

    1993-01-01

    Central volume expansion due to fluid shifts in weightlessness is believed to activate adaptive reflexes which ultimately result in a reduction of the total circulating blood volume. However, the flight data suggests that a central volume overdistention does not persist, in which case some other factor or factors must be responsible for body fluid losses. We used a computer simulation to test the hypothesis that factors other than central volume overdistention are involved in the loss of blood volume and other body fluid volumes observed in weightlessness and in weightless simulations. Additionally, the simulation was used to identify these factors. The results predict that atrial volumes and pressures return to their prebedrest baseline values within the first day of exposure to head down tilt (HDT) as the blood volume is reduced by an elevated urine formation. They indicate that the mechanisms for large and prolonged body fluid losses in weightlessness is red cell hemoconcentration that elevates blood viscosity and peripheral resistance, thereby lowering capillary pressure. This causes a prolonged alteration of the balance of Starling forces, depressing the extracellular fluid volume until the hematocrit is returned to normal through a reduction of the red cell mass, which also allows some restoration of the plasma volume. We conclude that the red cell mass becomes the physiologic driver for a large 'undershoot' of the body fluid volumes after the normalization of atrial volumes and pressures.

  4. Sys-BodyFluid: a systematical database for human body fluid proteome research

    PubMed Central

    Li, Su-Jun; Peng, Mao; Li, Hong; Liu, Bo-Shu; Wang, Chuan; Wu, Jia-Rui; Li, Yi-Xue; Zeng, Rong

    2009-01-01

    Recently, body fluids have widely become an important target for proteomic research and proteomic study has produced more and more body fluid related protein data. A database is needed to collect and analyze these proteome data. Thus, we developed this web-based body fluid proteome database Sys-BodyFluid. It contains eleven kinds of body fluid proteomes, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, seminal fluid, human milk and amniotic fluid. Over 10 000 proteins are presented in the Sys-BodyFluid. Sys-BodyFluid provides the detailed protein annotations, including protein description, Gene Ontology, domain information, protein sequence and involved pathways. These proteome data can be retrieved by using protein name, protein accession number and sequence similarity. In addition, users can query between these different body fluids to get the different proteins identification information. Sys-BodyFluid database can facilitate the body fluid proteomics and disease proteomics research as a reference database. It is available at http://www.biosino.org/bodyfluid/. PMID:18978022

  5. Sys-BodyFluid: a systematical database for human body fluid proteome research.

    PubMed

    Li, Su-Jun; Peng, Mao; Li, Hong; Liu, Bo-Shu; Wang, Chuan; Wu, Jia-Rui; Li, Yi-Xue; Zeng, Rong

    2009-01-01

    Recently, body fluids have widely become an important target for proteomic research and proteomic study has produced more and more body fluid related protein data. A database is needed to collect and analyze these proteome data. Thus, we developed this web-based body fluid proteome database Sys-BodyFluid. It contains eleven kinds of body fluid proteomes, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, seminal fluid, human milk and amniotic fluid. Over 10,000 proteins are presented in the Sys-BodyFluid. Sys-BodyFluid provides the detailed protein annotations, including protein description, Gene Ontology, domain information, protein sequence and involved pathways. These proteome data can be retrieved by using protein name, protein accession number and sequence similarity. In addition, users can query between these different body fluids to get the different proteins identification information. Sys-BodyFluid database can facilitate the body fluid proteomics and disease proteomics research as a reference database. It is available at http://www.biosino.org/bodyfluid/.

  6. Calculation of Water Entry Problem for Free-falling Bodies Using a Developed Cartesian Cut Cell Mesh

    NASA Astrophysics Data System (ADS)

    Wenhua, Wang; Yanying, Wang

    2010-05-01

    This paper describes the development of free surface capturing method on Cartesian cut cell mesh to water entry problem for free-falling bodies with body-fluid interaction. The incompressible Euler equations for a variable density fluid system are presented as governing equations and the free surface is treated as a contact discontinuity by using free surface capturing method. In order to be convenient for dealing with the problem with moving body boundary, the Cartesian cut cell technique is adopted for generating the boundary-fitted mesh around body edge by cutting solid regions out of a background Cartesian mesh. Based on this mesh system, governing equations are discretized by finite volume method, and at each cell edge inviscid flux is evaluated by means of Roe's approximate Riemann solver. Furthermore, for unsteady calculation in time domain, a time accurate solution is achieved by a dual time-stepping technique with artificial compressibility method. For the body-fluid interaction, the projection method of momentum equations and exact Riemann solution are applied in the calculation of fluid pressure on the solid boundary. Finally, the method is validated by test case of water entry for free-falling bodies.

  7. Computer simulation of preflight blood volume reduction as a countermeasure to fluid shifts in space flight

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Srinivasan, R.; Charles, J. B.

    1992-01-01

    Fluid shifts in weightlessness may cause a central volume expansion, activating reflexes to reduce the blood volume. Computer simulation was used to test the hypothesis that preadaptation of the blood volume prior to exposure to weightlessness could counteract the central volume expansion due to fluid shifts and thereby attenuate the circulatory and renal responses resulting in large losses of fluid from body water compartments. The Guyton Model of Fluid, Electrolyte, and Circulatory Regulation was modified to simulate the six degree head down tilt that is frequently use as an experimental analog of weightlessness in bedrest studies. Simulation results show that preadaptation of the blood volume by a procedure resembling a blood donation immediately before head down bedrest is beneficial in damping the physiologic responses to fluid shifts and reducing body fluid losses. After ten hours of head down tilt, blood volume after preadaptation is higher than control for 20 to 30 days of bedrest. Preadaptation also produces potentially beneficial higher extracellular volume and total body water for 20 to 30 days of bedrest.

  8. Oscillatory motion based measurement method and sensor for measuring wall shear stress due to fluid flow

    DOEpatents

    Armstrong, William D [Laramie, WY; Naughton, Jonathan [Laramie, WY; Lindberg, William R [Laramie, WY

    2008-09-02

    A shear stress sensor for measuring fluid wall shear stress on a test surface is provided. The wall shear stress sensor is comprised of an active sensing surface and a sensor body. An elastic mechanism mounted between the active sensing surface and the sensor body allows movement between the active sensing surface and the sensor body. A driving mechanism forces the shear stress sensor to oscillate. A measuring mechanism measures displacement of the active sensing surface relative to the sensor body. The sensor may be operated under periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor measurably changes the amplitude or phase of the motion of the active sensing surface, or changes the force and power required from a control system in order to maintain constant motion. The device may be operated under non-periodic excitation where changes in the nature of the fluid properties or the fluid flow over the sensor change the transient motion of the active sensor surface or change the force and power required from a control system to maintain a specified transient motion of the active sensor surface.

  9. Advanced statistical analysis of Raman spectroscopic data for the identification of body fluid traces: semen and blood mixtures.

    PubMed

    Sikirzhytski, Vitali; Sikirzhytskaya, Aliaksandra; Lednev, Igor K

    2012-10-10

    Conventional confirmatory biochemical tests used in the forensic analysis of body fluid traces found at a crime scene are destructive and not universal. Recently, we reported on the application of near-infrared (NIR) Raman microspectroscopy for non-destructive confirmatory identification of pure blood, saliva, semen, vaginal fluid and sweat. Here we expand the method to include dry mixtures of semen and blood. A classification algorithm was developed for differentiating pure body fluids and their mixtures. The classification methodology is based on an effective combination of Support Vector Machine (SVM) regression (data selection) and SVM Discriminant Analysis of preprocessed experimental Raman spectra collected using an automatic mapping of the sample. This extensive cross-validation of the obtained results demonstrated that the detection limit of the minor contributor is as low as a few percent. The developed methodology can be further expanded to any binary mixture of complex solutions, including but not limited to mixtures of other body fluids. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  10. Chloride Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... there is a problem with your body's electrolyte balance or acid-base (pH) balance and to monitor ...

  11. A comparative analysis of conventional cytopreparatory and liquid based cytological techniques (Sure Path) in evaluation of serous effusion fluids.

    PubMed

    Dadhich, Hrishikesh; Toi, Pampa Ch; Siddaraju, Neelaiah; Sevvanthi, Kalidas

    2016-11-01

    Clinically, detection of malignant cells in serous body fluids is critical, as their presence implies the upstaging of the disease. Cytology of body cavity fluids serves as an important tool when other diagnostic tests cannot be performed. In most laboratories, currently, the effusion fluid samples are analysed chiefly by the conventional cytopreparatory (CCP) technique. Although, there are several studies comparing the liquid-based cytology (LBC), with CCP technique in the field of cervicovaginal cytology; the literature on such comparison with respect to serous body fluid examination is sparse. One hundred samples of serous body fluids were processed by both CCP and LBC techniques. Slides prepared by these techniques were studied using six parameters. A comparative analysis of the advantages and disadvantages of the techniques in detection of malignant cells was carried out with appropriate statistical tests. The samples comprised 52 pleural, 44 peritoneal and four pericardial fluids. No statistically significant difference was noted with respect to cellularity (P values = 0.22), cell distribution (P values = 0.39) and diagnosis of malignancy (P values = 0.20). As for the remaining parameters, LBC provided statistically significant clearer smear background (P values < 0.0001) and shorter screening time (P values < 0.0001), while CPP technique provided a significantly better staining quality (P values 0.01) and sharper cytomorphologic features (P values 0.05). Although, a reduced screening time and clearer smear background are the two major advantages of LBC; the CCP technique provides the better staining quality with sharper cytomorphologic features which is more critical from the cytologic interpretation point of view. Diagn. Cytopathol. 2016;44:874-879. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  12. Mass spectrometry-based cDNA profiling as a potential tool for human body fluid identification.

    PubMed

    Donfack, Joseph; Wiley, Anissa

    2015-05-01

    Several mRNA markers have been exhaustively evaluated for the identification of human venous blood, saliva, and semen in forensic genetics. As new candidate human body fluid specific markers are discovered, evaluated, and reported in the scientific literature, there is an increasing trend toward determining the ideal markers for cDNA profiling of body fluids of forensic interest. However, it has not been determined which molecular genetics-based technique(s) should be utilized to assess the performance of these markers. In recent years, only a few confirmatory, mRNA/cDNA-based methods have been evaluated for applications in body fluid identification. The most frequently described methods tested to date include quantitative polymerase chain reaction (qPCR) and capillary electrophoresis (CE). However these methods, in particular qPCR, often favor narrow multiplex PCR due to the availability of a limited number of fluorescent dyes/tags. In an attempt to address this technological constraint, this study explored matrix-assisted laser desorption/ionization-time of flight mass spectrometry (MALDI-TOF MS) for human body fluid identification via cDNA profiling of venous blood, saliva, and semen. Using cDNA samples at 20pg input phosphoglycerate kinase 1 (PGK1) amounts, body fluid specific markers for the candidate genes were amplified in their corresponding body fluid (i.e., venous blood, saliva, or semen) and absent in the remaining two (100% specificity). The results of this study provide an initial indication that MALDI-TOF MS is a potential fluorescent dye-free alternative method for body fluid identification in forensic casework. However, the inherent issues of low amounts of mRNA, and the damage caused to mRNA by environmental exposures, extraction processes, and storage conditions are important factors that significantly hinder the implementation of cDNA profiling into forensic casework. Published by Elsevier Ireland Ltd.

  13. Blood Test: Basic Metabolic Panel (BMP)

    MedlinePlus

    ... the body's fluid levels and its acid-base balance. Normal levels of these electrolytes help keep cells in the body working as they should. Blood urea nitrogen (BUN) and creatinine , which are waste products filtered ...

  14. Blood Test: Comprehensive Metabolic Panel (CMP)

    MedlinePlus

    ... the body's fluid levels and its acid-base balance. Normal levels of these electrolytes help keep cells in the body working as they should. Blood urea nitrogen (BUN) and creatinine , which are waste products filtered ...

  15. Laboratory testing of extravascular body fluids in Croatia: a survey of the Working group for extravascular body fluids of the Croatian Society of Medical Biochemistry and Laboratory Medicine

    PubMed Central

    Kopcinovic, Lara Milevoj; Vogrinc, Zeljka; Kocijan, Irena; Culej, Jelena; Aralica, Merica; Jokic, Anja; Antoncic, Dragana; Bozovic, Marija

    2016-01-01

    Introduction We hypothesized that extravascular body fluid (EBF) analysis in Croatia is not harmonized and aimed to investigate preanalytical, analytical and postanalytical procedures used in EBF analysis in order to identify key aspects that should be addressed in future harmonization attempts. Materials and methods An anonymous online survey created to explore laboratory testing of EBF was sent to secondary, tertiary and private health care Medical Biochemistry Laboratories (MBLs) in Croatia. Statements were designed to address preanalytical, analytical and postanalytical procedures of cerebrospinal, pleural, peritoneal (ascites), pericardial, seminal, synovial, amniotic fluid and sweat. Participants were asked to declare the strength of agreement with proposed statements using a Likert scale. Mean scores for corresponding separate statements divided according to health care setting were calculated and compared. Results The survey response rate was 0.64 (58 / 90). None of the participating private MBLs declared to analyse EBF. We report a mean score of 3.45 obtained for all statements evaluated. Deviations from desirable procedures were demonstrated in all EBF testing phases. Minor differences in procedures used for EBF analysis comparing secondary and tertiary health care MBLs were found. The lowest scores were obtained for statements regarding quality control procedures in EBF analysis, participation in proficiency testing programmes and provision of interpretative comments on EBF’s test reports. Conclusions Although good laboratory EBF practice is present in Croatia, procedures for EBF analysis should be further harmonized to improve the quality of EBF testing and patient safety. PMID:27812307

  16. Poly(ethylene glycol)/chitosan/sodium glycerophosphate gel replaced the joint capsule with slow-release lubricant after joint surgery.

    PubMed

    Lu, Hailin; Ren, Shanshan; Li, Xing; Guo, Junde; Dong, Guangneng; Li, Jianhui; Gao, Li

    2018-08-01

    Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.

  17. Rethinking liquid biopsy: Microfluidic assays for mobile tumor cells in human body fluids.

    PubMed

    Neoh, Kuang Hong; Hassan, Ayon Ahmed; Chen, Anqi; Sun, Yukun; Liu, Peng; Xu, Kai-Feng; Wong, Alice S T; Han, Ray P S

    2018-01-01

    Traditionally, liquid biopsy is a blood test involving the harvesting of tumor materials from peripheral blood. Tumor cells from non-blood body fluids have always been clinically available in cytological examinations but limited for use in differential diagnosis due to the low sensitivity of conventional cytopathology. With the recent significant progress in microfluidic and downstream molecular technologies, liquid biopsies have now evolved to include harvesting tumor cells and DNA fragments in all kinds of non-blood body fluids. This expansion into general body fluids presages the notion that liquid biopsy could soon be used in competition, as well as, in complementarity with tissue biopsy. Preliminary research of fluid-harvested tumor materials to spot early-stage tumors, monitor disease progression for metastasis and recurrence, and detect chemoresistance have been reported. To reflect the propagation of tumor cells in non-blood body fluids, we introduced the term Mobile Tumor Cells (MTCs), in lieu of the widely accepted term of circulating tumor cells (CTCs) resident in the bloodstream. Our review starts with a discussion on the clinical significance of MTCs, followed by a presentation of microfluidic techniques for MTC capture and various strategies for their identification. Hopefully, the phenotypic and genomic data acquired from harvested MTCs can be used to guide and improve cancer treatment decisions. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. A study analysis of cable-body systems totally immersed in a fluid stream

    NASA Technical Reports Server (NTRS)

    Delaurier, J. D.

    1972-01-01

    A general stability analysis of a cable-body system immersed in a fluid stream is presented. The analytical portion of this analysis treats the system as being essentially a cable problem, with the body dynamics giving the end conditions. The mathematical form of the analysis consists of partial differential wave equations, with the end and auxiliary conditions being determined from the body equations of motion. The equations uncouple to give a lateral problem and a longitudinal problem as in first order airplane dynamics. A series of tests on a tethered wind tunnel model provide a comparison of the theory with experiment.

  19. Forensic differentiation between peripheral and menstrual blood in cases of alleged sexual assault-validating an immunochromatographic multiplex assay for simultaneous detection of human hemoglobin and D-dimer.

    PubMed

    Holtkötter, Hannah; Dias Filho, Claudemir Rodrigues; Schwender, Kristina; Stadler, Christian; Vennemann, Marielle; Pacheco, Ana Claudia; Roca, Gabriela

    2018-05-01

    Sexual assault is a serious offense and identification of body fluids originating from sexual activity has been a crucial aspect of forensic investigations for a long time. While reliable tests for the detection of semen and saliva have been successfully implemented into forensic laboratories, the detection of other body fluids, such as vaginal or menstrual fluid, is more challenging. Especially, the discrimination between peripheral and menstrual blood can be highly relevant for police investigations because it provides potential evidence regarding the issue of consent. We report the forensic validation of an immunochromatographic test that allows for such discrimination in forensic stains, the SERATEC PMB test, and its performance on real casework samples. The PMB test is a duplex test combining human hemoglobin and D-dimer detection and was developed for the identification of blood and menstrual fluid, both at the crime scene and in the laboratory. The results of this study showed that the duplex D-dimer/hemoglobin assay reliably detects the presence of human hemoglobin and identifies samples containing menstrual fluid by detecting the presence of D-dimers. The method distinguished between menstrual and peripheral blood in a swab from a historical artifact and in real casework samples of alleged sexual assaults. Results show that the development of the new duplex test is a substantial progress towards analyzing and interpreting evidence from sexual assault cases.

  20. Effects of implant design parameters on fluid convection, potentiating third-body debris ingress into the bearing surface during THA impingement/subluxation.

    PubMed

    Lundberg, Hannah J; Pedersen, Douglas R; Baer, Thomas E; Muste, Marian; Callaghan, John J; Brown, Thomas D

    2007-01-01

    Aseptic loosening from polyethylene wear debris is the leading cause of failure for metal-on-polyethylene total hip implants. Third-body debris ingress to the bearing space results in femoral head roughening and acceleration of polyethylene wear. How third-body particles manage to enter the bearing space between the closely conforming articulating surfaces of the joint is not well understood. We hypothesize that one such mechanism is from convective fluid transport during subluxation of the total hip joint. To test this hypothesis, a three-dimensional (3D) computational fluid dynamics (CFD) model was developed and validated, to quantify fluid ingress into the bearing space during a leg-cross subluxation event. The results indicated that extra-articular joint fluid could be drawn nearly to the pole of the cup with even very small separations of the femoral head (<0.60mm). Debris suspended near the equator of the cup at the site of maximum fluid velocity just before the subluxation began could be transported to within 11 degrees from the cup pole. Larger head diameters resulted in increased fluid velocity at all sites around the entrance to the gap compared to smaller head sizes, with fluid velocity being greatest along the anterosuperolateral cup edge, for all head sizes. Fluid pathlines indicated that suspended debris would reach similar angular positions in the bearing space regardless of head size. Increased inset of the femoral head into the acetabular cup resulted both in higher fluid velocity and in transport of third-body debris further into the bearing space.

  1. Unsteady bio-fluid dynamics in flying and swimming

    NASA Astrophysics Data System (ADS)

    Liu, Hao; Kolomenskiy, Dmitry; Nakata, Toshiyuki; Li, Gen

    2017-08-01

    Flying and swimming in nature present sophisticated and exciting ventures in biomimetics, which seeks sustainable solutions and solves practical problems by emulating nature's time-tested patterns, functions, and strategies. Bio-fluids in insect and bird flight, as well as in fish swimming are highly dynamic and unsteady; however, they have been studied mostly with a focus on the phenomena associated with a body or wings moving in a steady flow. Characterized by unsteady wing flapping and body undulation, fluid-structure interactions, flexible wings and bodies, turbulent environments, and complex maneuver, bio-fluid dynamics normally have challenges associated with low Reynolds number regime and high unsteadiness in modeling and analysis of flow physics. In this article, we review and highlight recent advances in unsteady bio-fluid dynamics in terms of leading-edge vortices, passive mechanisms in flexible wings and hinges, flapping flight in unsteady environments, and micro-structured aerodynamics in flapping flight, as well as undulatory swimming, flapping-fin hydrodynamics, body-fin interaction, C-start and maneuvering, swimming in turbulence, collective swimming, and micro-structured hydrodynamics in swimming. We further give a perspective outlook on future challenges and tasks of several key issues of the field.

  2. 21 CFR 866.5380 - Free secretory component immuno-logical test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... body fluids. Measurement of free secretory component (protein molecules) aids in the diagnosis or... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...

  3. 21 CFR 866.5380 - Free secretory component immuno-logical test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... body fluids. Measurement of free secretory component (protein molecules) aids in the diagnosis or... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...

  4. 21 CFR 866.5380 - Free secretory component immuno-logical test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... body fluids. Measurement of free secretory component (protein molecules) aids in the diagnosis or... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...

  5. 21 CFR 866.5380 - Free secretory component immuno-logical test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... body fluids. Measurement of free secretory component (protein molecules) aids in the diagnosis or... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test...

  6. 21 CFR 862.1540 - Osmolality test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... measure ionic and nonionic solute concentration in body fluids, such as serum and urine. Osmolality...

  7. 21 CFR 862.1540 - Osmolality test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... measure ionic and nonionic solute concentration in body fluids, such as serum and urine. Osmolality...

  8. 21 CFR 862.1540 - Osmolality test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... measure ionic and nonionic solute concentration in body fluids, such as serum and urine. Osmolality...

  9. 21 CFR 862.1540 - Osmolality test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... measure ionic and nonionic solute concentration in body fluids, such as serum and urine. Osmolality...

  10. Extended specificity studies of mRNA assays used to infer human organ tissues and body fluids.

    PubMed

    van den Berge, Margreet; Sijen, Titia

    2017-12-01

    Messenger RNA (mRNA) profiling is a technique increasingly applied for the forensic identification of body fluids and skin. More recently, an mRNA-based organ typing assay was developed which allows for the inference of brain, lung, liver, skeletal muscle, heart, kidney, and skin tissue. When applying this organ typing system in forensic casework for the presence of animal, rather than human, tissue is an alternative scenario to be proposed, for instance that bullets carry cell material from a hunting event. Even though mRNA profiling systems are commonly in silico designed to be primate specific, physical testing against other animal species is generally limited. In this study, human specificity of the organ tissue inferring system was assessed against organ tissue RNAs of various animals. Results confirm human specificity of the system, especially when utilizing interpretation rules considering multiple markers per cell type. Besides, we cross-tested our organ and body fluid mRNA assays against the target types covered by the other assay. Marker expression in the nontarget organ tissues and body fluids was observed to a limited extent, which emphasizes the importance of involving the case-specific context of the forensic samples in deciding which mRNA profiling assay to use and when for interpreting results. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Osmolality Test

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... osmotic gap, tests for blood sodium, blood urea nitrogen (BUN) , and glucose must be performed to calculate ...

  12. 21 CFR 862.1345 - Glucose test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and...

  13. 21 CFR 862.1345 - Glucose test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and...

  14. 21 CFR 862.1345 - Glucose test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... glucose quantitatively in blood and other body fluids. Glucose measurements are used in the diagnosis and...

  15. Low-speed Aerodynamic Investigations of a Hybrid Wing Body Configuration

    NASA Technical Reports Server (NTRS)

    Vicroy, Dan D.; Gatlin, Gregory M.; Jenkins, Luther N.; Murphy, Patrick C.; Carter, Melissa B.

    2014-01-01

    Two low-speed static wind tunnel tests and a water tunnel static and dynamic forced-motion test have been conducted on a hybrid wing-body (HWB) twinjet configuration. These tests, in addition to computational fluid dynamics (CFD) analysis, have provided a comprehensive dataset of the low-speed aerodynamic characteristics of this nonproprietary configuration. In addition to force and moment measurements, the tests included surface pressures, flow visualization, and off-body particle image velocimetry measurements. This paper will summarize the results of these tests and highlight the data that is available for code comparison or additional analysis.

  16. A comprehensive Guyton model analysis of physiologic responses to preadapting the blood volume as a countermeasure to fluid shifts

    NASA Technical Reports Server (NTRS)

    Simanonok, K. E.; Srinivasan, R. S.; Myrick, E. E.; Blomkalns, A. L.; Charles, J. B.

    1994-01-01

    The Guyton model of fluid, electrolyte, and circulatory regulation is an extensive mathematical model capable of simulating a variety of experimental conditions. It has been modified for use at NASA to simulate head-down tilt, a frequently used analog of weightlessness. Weightlessness causes a headward shift of body fluids that is believed to expand central blood volume, triggering a series of physiologic responses resulting in large losses of body fluids. We used the modified Guyton model to test the hypothesis that preadaptation of the blood volume before weightless exposure could counteract the central volume expansion caused by fluid shifts, and thereby attenuate the circulatory and renal responses that result in body fluid losses. Simulation results show that circulatory preadaptation, by a procedure resembling blood donation immediately before head-down bedrest, is effective in damping the physiologic responses to fluid shifts and reducing body fluid losses. After 10 hours of head-down tilt, preadaptation also produces higher blood volume, extracellular volume, and total body water for 20 to 30 days of bedrest, compared with non-preadapted control. These results indicate that circulatory preadaptation before current Space Shuttle missions may be beneficial for the maintenance of reentry and postflight orthostatic tolerance in astronauts. This paper presents a comprehensive examination of the simulation results pertaining to changes in relevant physiologic variables produced by blood volume reduction before a prolonged head-down tilt. The objectives were to study and develop the countermeasure theoretically, to aid in planning experimental studies of the countermeasure, and to identify potentially disadvantageous physiologic responses that may be caused by the countermeasure.

  17. Bioactivity and electrochemical behavior of hydroxyapatite-silicon-multi walled carbon nano-tubes composite coatings synthesized by EPD on NiTi alloys in simulated body fluid.

    PubMed

    Khalili, V; Khalil-Allafi, J; Frenzel, J; Eggeler, G

    2017-02-01

    In order to improve the surface bioactivity of NiTi bone implant and corrosion resistance, hydroxyapatite coating with addition of 20wt% silicon, 1wt% multi walled carbon nano-tubes and both of them were deposited on a NiTi substrate using a cathodic electrophoretic method. The apatite formation ability was estimated using immersion test in the simulated body fluid for 10days. The SEM images of the surface of coatings after immersion in simulated body fluid show that the presence of silicon in the hydroxyapatite coatings accelerates in vitro growth of apatite layer on the coatings. The Open-circuit potential and electrochemical impedance spectroscopy were measured to evaluate the electrochemical behavior of the coatings in the simulated body fluid at 37°C. The results indicate that the compact structure of hydroxyapatite-20wt% silicon and hydroxyapatite-20wt% silicon-1wt% multi walled carbon nano-tubes coatings could efficiently increase the corrosion resistance of NiTi substrate. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. 21 CFR 862.1725 - Trypsin test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... other body fluids and in feces. Measurements obtained by this device are used in the diagnosis and...

  19. 21 CFR 862.1725 - Trypsin test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... other body fluids and in feces. Measurements obtained by this device are used in the diagnosis and...

  20. 21 CFR 862.1725 - Trypsin test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... other body fluids and in feces. Measurements obtained by this device are used in the diagnosis and...

  1. 21 CFR 862.1725 - Trypsin test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... other body fluids and in feces. Measurements obtained by this device are used in the diagnosis and...

  2. 21 CFR 862.3040 - Alcohol test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and...

  3. 21 CFR 862.3040 - Alcohol test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and...

  4. 21 CFR 862.3040 - Alcohol test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Toxicology Test Systems § 862... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and...

  5. 21 CFR 862.1725 - Trypsin test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... other body fluids and in feces. Measurements obtained by this device are used in the diagnosis and...

  6. 21 CFR 862.1180 - Chymotrypsin test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... measure the activity of the enzyme chymotrypsin in blood and other body fluids and in feces. Chymotrypsin...

  7. 21 CFR 862.1230 - Cyclic AMP test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Chemistry Test Systems § 862... measure the level of adenosine 3′, 5′-monophosphate (cyclic AMP) in plasma, urine, and other body fluids...

  8. Heart Health Tests for Diabetes Patients

    MedlinePlus

    ... or fluids in the body. They include: Electrocardiogram ("EKG" or "ECG") This test measures the electrical activity ... Tools & Resources Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  9. In Vitro Degradation Behaviors of Manganese-Calcium Phosphate Coatings on an Mg-Ca-Zn Alloy

    PubMed Central

    Su, Yichang; Su, Yingchao; Zai, Wei

    2018-01-01

    In order to decrease the degradation rate of magnesium (Mg) alloys for the potential orthopedic applications, manganese-calcium phosphate coatings were prepared on an Mg-Ca-Zn alloy in calcium phosphating solutions with different addition of Mn2+. Influence of Mn content on degradation behaviors of phosphate coatings in the simulated body fluid was investigated to obtain the optimum coating. With the increasing Mn addition, the corrosion resistance of the manganese-calcium phosphate coatings was gradually improved. The optimum coating prepared in solution containing 0.05 mol/L Mn2+ had a uniform and compact microstructure and was composed of MnHPO4·3H2O, CaHPO4·2H2O, and Ca3(PO4)2. The electrochemical corrosion test in simulated body fluid revealed that polarization resistance of the optimum coating is 36273 Ωcm2, which is about 11 times higher than that of phosphate coating without Mn addition. The optimum coating also showed the most stable surface structure and lowest hydrogen release in the immersion test in simulated body fluid. PMID:29643970

  10. CCFP Analyzer

    NASA Image and Video Library

    2016-05-06

    ISS047e106715 (05/06/2016) --- ESA (European Space Agency astronaut Tim Peake unpacks a cerebral and cochlear fluid pressure (CCFP) analyzer. The device is being tested to measure the pressure of the fluid in the skull, also known as intracranial pressure, which may increase due to fluid shifts in the body while in microgravity. It is hypothesized that the headward fluid shift that occurs during space flight leads to increased pressure in the brain, which may push on the back of the eye, causing it to change shape.

  11. Evaluation of a standardized procedure for [corrected] microscopic cell counts [corrected] in body fluids.

    PubMed

    Emerson, Jane F; Emerson, Scott S

    2005-01-01

    A standardized urinalysis and manual microscopic cell counting system was evaluated for its potential to reduce intra- and interoperator variability in urine and cerebrospinal fluid (CSF) cell counts. Replicate aliquots of pooled specimens were submitted blindly to technologists who were instructed to use either the Kova system with the disposable Glasstic slide (Hycor Biomedical, Inc., Garden Grove, CA) or the standard operating procedure of the University of California-Irvine (UCI), which uses plain glass slides for urine sediments and hemacytometers for CSF. The Hycor system provides a mechanical means of obtaining a fixed volume of fluid in which to resuspend the sediment, and fixes the volume of specimen to be microscopically examined by using capillary filling of a chamber containing in-plane counting grids. Ninety aliquots of pooled specimens of each type of body fluid were used to assess the inter- and intraoperator reproducibility of the measurements. The variability of replicate Hycor measurements made on a single specimen by the same or different observers was compared with that predicted by a Poisson distribution. The Hycor methods generally resulted in test statistics that were slightly lower than those obtained with the laboratory standard methods, indicating a trend toward decreasing the effects of various sources of variability. For 15 paired aliquots of each body fluid, tests for systematically higher or lower measurements with the Hycor methods were performed using the Wilcoxon signed-rank test. Also examined was the average difference between the Hycor and current laboratory standard measurements, along with a 95% confidence interval (CI) for the true average difference. Without increasing labor or the requirement for attention to detail, the Hycor method provides slightly better interrater comparisons than the current method used at UCI. Copyright 2005 Wiley-Liss, Inc.

  12. Aerothermodynamics of Blunt Body Entry Vehicles. Chapter 3

    NASA Technical Reports Server (NTRS)

    Hollis, Brian R.; Borrelli, Salvatore

    2011-01-01

    In this chapter, the aerothermodynamic phenomena of blunt body entry vehicles are discussed. Four topics will be considered that present challenges to current computational modeling techniques for blunt body environments: turbulent flow, non-equilibrium flow, rarefied flow, and radiation transport. Examples of comparisons between computational tools to ground and flight-test data will be presented in order to illustrate the challenges existing in the numerical modeling of each of these phenomena and to provide test cases for evaluation of Computational Fluid Dynamics (CFD) code predictions.

  13. Aerothermodynamics of blunt body entry vehicles

    NASA Astrophysics Data System (ADS)

    Hollis, Brian R.; Borrelli, Salvatore

    2012-01-01

    In this chapter, the aerothermodynamic phenomena of blunt body entry vehicles are discussed. Four topics will be considered that present challenges to current computational modeling techniques for blunt body environments: turbulent flow, non-equilibrium flow, rarefied flow, and radiation transport. Examples of comparisons between computational tools to ground and flight-test data will be presented in order to illustrate the challenges existing in the numerical modeling of each of these phenomena and to provide test cases for evaluation of computational fluid dynamics (CFD) code predictions.

  14. Evaluation of single and stack membraneless enzymatic fuel cells based on ethanol in simulated body fluids.

    PubMed

    Galindo-de-la-Rosa, J; Arjona, N; Moreno-Zuria, A; Ortiz-Ortega, E; Guerra-Balcázar, M; Ledesma-García, J; Arriaga, L G

    2017-06-15

    The purpose of this work is to evaluate single and double-cell membraneless microfluidic fuel cells (MMFCs) that operate in the presence of simulated body fluids SBF, human serum and blood enriched with ethanol as fuels. The study was performed using the alcohol dehydrogenase enzyme immobilised by covalent binding through an array composed of carbon Toray paper as support and a layer of poly(methylene blue)/tetrabutylammonium bromide/Nafion and glutaraldehyde (3D bioanode electrode). The single MMFC was tested in a hybrid microfluidic fuel cell using Pt/C as the cathode. A cell voltage of 1.035V and power density of 3.154mWcm -2 were observed, which is the highest performance reported to date. The stability and durability were tested through chronoamperometry and polarisation/performance curves obtained at different days, which demonstrated a slow decrease in the power density on day 10 (14%) and day 20 (26%). Additionally, the cell was tested for ethanol oxidation in simulated body fluid (SBF) with ionic composition similar to human blood plasma. Those tests resulted in 0.93V of cell voltage and a power density close to 1.237mWcm -2 . The double cell MMFC (Stack) was tested using serum and human blood enriched with ethanol. The stack operated with blood in a serial connection showed an excellent cell performance (0.716mWcm -2 ), demonstrating the feasibility of employing human blood as energy source. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Fluid Shifts

    NASA Technical Reports Server (NTRS)

    Stenger, M. B.; Hargens, A. R.; Dulchavsky, S. A.; Arbeille, P.; Danielson, R. W.; Ebert, D. J.; Garcia, K. M.; Johnston, S. L.; Laurie, S. S.; Lee, S. M. C.; hide

    2017-01-01

    Introduction. NASA's Human Research Program is focused on addressing health risks associated with long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but now more than 50 percent of ISS astronauts have experienced more profound, chronic changes with objective structural findings such as optic disc edema, globe flattening and choroidal folds. These structural and functional changes are referred to as the visual impairment and intracranial pressure (VIIP) syndrome. Development of VIIP symptoms may be related to elevated intracranial pressure (ICP) secondary to spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight and to determine if a relation exists with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as any VIIP-related effects of those shifts, are predicted by the crewmember's pre-flight status and responses to acute hemodynamic manipulations, specifically posture changes and lower body negative pressure. Methods. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, and calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography; intraocular pressure; 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness; Doppler ultrasound of ophthalmic and retinal arteries and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, otoacoustic emissions). Pre- and post-flight, acute head-down tilt will induce cephalad fluid shifts, whereas lower body negative pressure will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. Discussion. Ten subjects have consented to participate in this experiment, including the recent One-Year Mission crewmembers, who have recently completed R plus180 testing; all other subjects have completed pre-flight testing. Preliminary results from the One-Year Mission crewmembers will be presented, including measures of ocular structure and function, vascular dimensions, fluid distribution, and non-invasive estimates of intracranial pressure.

  16. Strongly Coupled Fluid-Body Dynamics in the Immersed Boundary Projection Method

    NASA Astrophysics Data System (ADS)

    Wang, Chengjie; Eldredge, Jeff D.

    2014-11-01

    A computational algorithm is developed to simulate dynamically coupled interaction between fluid and rigid bodies. The basic computational framework is built upon a multi-domain immersed boundary method library, whirl, developed in previous work. In this library, the Navier-Stokes equations for incompressible flow are solved on a uniform Cartesian grid by the vorticity-based immersed boundary projection method of Colonius and Taira. A solver for the dynamics of rigid-body systems is also included. The fluid and rigid-body solvers are strongly coupled with an iterative approach based on the block Gauss-Seidel method. Interfacial force, with its intimate connection with the Lagrange multipliers used in the fluid solver, is used as the primary iteration variable. Relaxation, developed from a stability analysis of the iterative scheme, is used to achieve convergence in only 2-4 iterations per time step. Several two- and three-dimensional numerical tests are conducted to validate and demonstrate the method, including flapping of flexible wings, self-excited oscillations of a system of linked plates and three-dimensional propulsion of flexible fluked tail. This work has been supported by AFOSR, under Award FA9550-11-1-0098.

  17. Disseminated cryptococcosis and fluconazole resistant oral candidiasis in a patient with acquired immunodeficiency syndrome (AIDS).

    PubMed

    Kothavade, Rajendra J; Oberai, Chetan M; Valand, Arvind G; Panthaki, Mehroo H

    2010-10-28

    Disseminated cryptococcosis and recurrent oral candidiasis was presented in a-heterosexual AIDS patient. Candida tropicalis (C.tropicalis) was isolated from the oral pseudomembranous plaques and Cryptococcus neoformans (C. neoformans) was isolated from maculopapular lesions on body parts (face, hands and chest) and body fluids (urine, expectorated sputum, and cerebrospinal fluid). In vitro drug susceptibility testing on the yeast isolates demonstrated resistance to fluconazole acquired by C. tropicalis which was a suggestive possible root cause of recurrent oral candidiasis in this patient.

  18. 21 CFR 866.5660 - Multiple autoantibodies immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... 866.5660 Section 866.5660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the autoantibodies (antibodies produced against the body's own tissues) in serum and other body fluids. Measurement of multiple autoantibodies aids in the diagnosis of autoimmune disorders (disease produced when...

  19. 21 CFR 866.5660 - Multiple autoantibodies immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... 866.5660 Section 866.5660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the autoantibodies (antibodies produced against the body's own tissues) in serum and other body fluids. Measurement of multiple autoantibodies aids in the diagnosis of autoimmune disorders (disease produced when...

  20. 21 CFR 866.5660 - Multiple autoantibodies immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... 866.5660 Section 866.5660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the autoantibodies (antibodies produced against the body's own tissues) in serum and other body fluids. Measurement of multiple autoantibodies aids in the diagnosis of autoimmune disorders (disease produced when...

  1. 21 CFR 866.5660 - Multiple autoantibodies immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... 866.5660 Section 866.5660 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the autoantibodies (antibodies produced against the body's own tissues) in serum and other body fluids. Measurement of multiple autoantibodies aids in the diagnosis of autoimmune disorders (disease produced when...

  2. Preexercise Urine Specific Gravity and Fluid Intake During One-Hour Running in a Thermoneutral Environment – A Randomized Cross-Over Study

    PubMed Central

    Silva, Rafael P.; Mündel, Toby; Altoé, Janaína L.; Saldanha, Mônica R.; Ferreira, Fabrícia G.; Marins, João C.B.

    2010-01-01

    Urine specific gravity is often used to assess hydration status. Athletes who are hypohydrated prior to exercise tend to ingest more fluid during the exercise, possibly to compensate for their pre exercise fluid deficit. The purpose of this study was to evaluate the effect of additional fluid intake on fluid balance and gastrointestinal tract comfort during 1h running in a thermoneutral environment when athletes followed their habitual fluid and dietary regimes. Sixteen men and sixteen women ingested a 6% carbohydrate-electrolyte solution immediately prior to exercise and then every 15 minutes during two runs, with a consumption rate of 2 mL.kg-1 (LV, lower volume) or 3 mL.kg-1 (HV, higher volume) body mass. Urine specific gravity and body mass changes were determined before and after the tests to estimate hydration status. During exercise subjects verbally responded to surveys inquiring about gastrointestinal symptoms, sensation of thirst and ratings of perceived exertion. Plasma glucose, heart rate and blood pressure were also evaluated. Men had higher preexercise urine specific gravity than women (1.025 vs. 1.016 g·mL-1 HV; and 1.024 vs. 1.017 g·mL-1 LV) and greater sweat loss (1.21 ± 0.27 L vs. 0.83 ± 0.21 L HV; and 1.18 ± 0.23 L vs. 0.77 ± 0.17 LV). Prevalence of gastrointestinal discomfort increased after 45 min. No significant differences on heart rate, rate of perceived exertion, blood pressure or glycemia was observed with the additional fluid intake. From these results it appears that additional fluid intake reduces body mass loss and thirst sensation. When compared to the men, however, preexercise euhydration was more common in women and an increased fluid intake increases the risk of body mass gain and gastrointestinal discomfort. Key points There seems to be a wide variability in pre-exercise hydration status between male and female and efforts aimed at educating athletes about the importance of pregame hydration must be emphasized. The fluid ingestion during running exercise in a moderate environment reduces body mass loss and thirst sensation, but an increased fluid intake at rates to match the fluid loss might raise the risk of body mass gain in women during prolonged activities. Individual gastric tolerance and familiarization with fluid replacement should be taken into account when providing athletes with strategies for hydration during exercise. PMID:24149642

  3. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  4. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  5. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  6. 21 CFR 866.5470 - Hemoglobin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... hemoglobin (the oxygen-carrying pigment in red blood cells) in blood, urine, plasma, or other body fluids... Hemoglobin immunological test system. (a) Indentification. A hemoglobin immunological test system is a device... blood cells), and leukemia (cancer of the blood-forming organs). (b) Classification. Class II...

  7. A 3D, fully Eulerian, VOF-based solver to study the interaction between two fluids and moving rigid bodies using the fictitious domain method

    NASA Astrophysics Data System (ADS)

    Pathak, Ashish; Raessi, Mehdi

    2016-04-01

    We present a three-dimensional (3D) and fully Eulerian approach to capturing the interaction between two fluids and moving rigid structures by using the fictitious domain and volume-of-fluid (VOF) methods. The solid bodies can have arbitrarily complex geometry and can pierce the fluid-fluid interface, forming contact lines. The three-phase interfaces are resolved and reconstructed by using a VOF-based methodology. Then, a consistent scheme is employed for transporting mass and momentum, allowing for simulations of three-phase flows of large density ratios. The Eulerian approach significantly simplifies numerical resolution of the kinematics of rigid bodies of complex geometry and with six degrees of freedom. The fluid-structure interaction (FSI) is computed using the fictitious domain method. The methodology was developed in a message passing interface (MPI) parallel framework accelerated with graphics processing units (GPUs). The computationally intensive solution of the pressure Poisson equation is ported to GPUs, while the remaining calculations are performed on CPUs. The performance and accuracy of the methodology are assessed using an array of test cases, focusing individually on the flow solver and the FSI in surface-piercing configurations. Finally, an application of the proposed methodology in simulations of the ocean wave energy converters is presented.

  8. Roles of interstitial fluid pH in diabetes mellitus: Glycolysis and mitochondrial function

    PubMed Central

    Marunaka, Yoshinori

    2015-01-01

    The pH of body fluids is one the most important key factors regulating various cell function such as enzyme activity and protein-protein interaction via modification of its binding affinity. Therefore, to keep cell function normal, the pH of body fluids is maintained constant by various systems. Insulin resistance is one of the most important, serious factors making the body condition worse in diabetes mellitus. I have recently found that the pH of body (interstitial) fluids is lower in diabetes mellitus than that in non-diabetic control, and that the lowered pH is one of the causes producing insulin resistance. In this review article, I introduce importance of body (interstitial) fluid pH in regulation of body function, evidence on abnormal regulation of body fluid pH in diabetes mellitus, and relationship between the body fluid pH and insulin resistance. Further, this review proposes perspective therapies on the basis of regulation of body fluid pH including propolis (honeybee product) diet. PMID:25685283

  9. Short-term dynamic changes in hematologic and biochemical tests during follow-up of definite heart failure patients.

    PubMed

    Kataoka, Hajime

    2010-10-29

    There are few studies on the short-term changes in routine peripheral blood data in definite heart failure (HF) patients. This study examined whether or not such changes existed and evaluated the feasibility of monitoring changes in common blood tests to estimate body fluid status in HF patients. The blood test data both at worsening and recovery of HF status were obtained from 27 definite HF patients. Hemoglobin, hematocrit, total protein, albumin, and creatinine values were significantly lower during the period of worsening HF status than those obtained during a period of recent clinical stability. At recovery, the values of all measured blood markers had significantly increased compared to those obtained during the period of worsening HF status. At recovery, changes in body weight were negatively correlated with hemoglobin (r=-0.475, p=0.012), hematocrit (r=-0.429, p=0.026), and total protein (r=-0.442, p=0.021). Careful attention should be paid to short-term changes in routine blood tests to correctly interpret test results and to aid in monitoring body fluid status in HF patients. Copyright © 2009 Elsevier Ireland Ltd. All rights reserved.

  10. Computational Modeling of Space Physiology for Informing Spaceflight Countermeasure Design and Predictions of Efficacy

    NASA Technical Reports Server (NTRS)

    Lewandowski, B. E.; DeWitt, J. K.; Gallo, C. A.; Gilkey, K. M.; Godfrey, A. P.; Humphreys, B. T.; Jagodnik, K. M.; Kassemi, M.; Myers, J. G.; Nelson, E. S.; hide

    2017-01-01

    MOTIVATION: Spaceflight countermeasures mitigate the harmful effects of the space environment on astronaut health and performance. Exercise has historically been used as a countermeasure to physical deconditioning, and additional countermeasures including lower body negative pressure, blood flow occlusion and artificial gravity are being researched as countermeasures to spaceflight-induced fluid shifts. The NASA Digital Astronaut Project uses computational models of physiological systems to inform countermeasure design and to predict countermeasure efficacy.OVERVIEW: Computational modeling supports the development of the exercise devices that will be flown on NASAs new exploration crew vehicles. Biomechanical modeling is used to inform design requirements to ensure that exercises can be properly performed within the volume allocated for exercise and to determine whether the limited mass, volume and power requirements of the devices will affect biomechanical outcomes. Models of muscle atrophy and bone remodeling can predict device efficacy for protecting musculoskeletal health during long-duration missions. A lumped-parameter whole-body model of the fluids within the body, which includes the blood within the cardiovascular system, the cerebral spinal fluid, interstitial fluid and lymphatic system fluid, estimates compartmental changes in pressure and volume due to gravitational changes. These models simulate fluid shift countermeasure effects and predict the associated changes in tissue strain in areas of physiological interest to aid in predicting countermeasure effectiveness. SIGNIFICANCE: Development and testing of spaceflight countermeasure prototypes are resource-intensive efforts. Computational modeling can supplement this process by performing simulations that reduce the amount of necessary experimental testing. Outcomes of the simulations are often important for the definition of design requirements and the identification of factors essential in ensuring countermeasure efficacy.

  11. 21 CFR 866.5110 - Antiparietal antibody immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... absorbed by the body. The measurements aid in the diagnosis of vitamin B12 deficiency (or pernicious anemia.... 866.5110 Section 866.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the specific antibody for gastric parietal cells in serum and other body fluids. Gastric parietal...

  12. 21 CFR 866.5110 - Antiparietal antibody immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... absorbed by the body. The measurements aid in the diagnosis of vitamin B12 deficiency (or pernicious anemia.... 866.5110 Section 866.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the specific antibody for gastric parietal cells in serum and other body fluids. Gastric parietal...

  13. 21 CFR 866.5270 - C-reactive protein immuno-logical test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the C-reactive protein in serum and other body fluids. Measurement of C-reactive protein aids in evaluation of the amount of injury to body tissues. (b) Classification. Class II (performance standards). ....5270 Section 866.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  14. 21 CFR 866.5270 - C-reactive protein immuno-logical test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the C-reactive protein in serum and other body fluids. Measurement of C-reactive protein aids in evaluation of the amount of injury to body tissues. (b) Classification. Class II (performance standards). ....5270 Section 866.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  15. 21 CFR 866.5270 - C-reactive protein immuno-logical test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the C-reactive protein in serum and other body fluids. Measurement of C-reactive protein aids in evaluation of the amount of injury to body tissues. (b) Classification. Class II (performance standards). ....5270 Section 866.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  16. 21 CFR 866.5110 - Antiparietal antibody immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... absorbed by the body. The measurements aid in the diagnosis of vitamin B12 deficiency (or pernicious anemia.... 866.5110 Section 866.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the specific antibody for gastric parietal cells in serum and other body fluids. Gastric parietal...

  17. 21 CFR 866.5270 - C-reactive protein immuno-logical test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the C-reactive protein in serum and other body fluids. Measurement of C-reactive protein aids in evaluation of the amount of injury to body tissues. (b) Classification. Class II (performance standards). ....5270 Section 866.5270 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  18. 21 CFR 866.5110 - Antiparietal antibody immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... absorbed by the body. The measurements aid in the diagnosis of vitamin B12 deficiency (or pernicious anemia.... 866.5110 Section 866.5110 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... the specific antibody for gastric parietal cells in serum and other body fluids. Gastric parietal...

  19. A fundamental approach to the sticking of insect residues to aircraft wings

    NASA Technical Reports Server (NTRS)

    Eiss, N. S., Jr.; Wightman, J. P.

    1983-01-01

    The sticking of insect residues to aircraft wings is investigated. The major topics of this review are: Experimentally tested methods, testing techniques, the effect of surface roughness height on aerodynamic drag, materials tested and, the adhesive properties of insect body fluids are reviewed.

  20. Enabling fluorescent biosensors for the forensic identification of body fluids.

    PubMed

    Frascione, Nunzianda; Gooch, James; Daniel, Barbara

    2013-11-12

    The search for body fluids often forms a crucial element of many forensic investigations. Confirming fluid presence at a scene can not only support or refute the circumstantial claims of a victim, suspect or witness, but may additionally provide a valuable source of DNA for further identification purposes. However, current biological fluid testing techniques are impaired by a number of well-characterised limitations; they often give false positives, cannot be used simultaneously, are sample destructive and lack the ability to visually locate fluid depositions. These disadvantages can negatively affect the outcome of a case through missed or misinterpreted evidence. Biosensors are devices able to transduce a biological recognition event into a measurable signal, resulting in real-time analyte detection. The use of innovative optical sensing technology may enable the highly specific and non-destructive detection of biological fluid depositions through interaction with several fluid-endogenous biomarkers. Despite considerable impact in a variety of analytical disciplines, biosensor application within forensic analyses may be considered extremely limited. This article aims to explore a number of prospective biosensing mechanisms and to outline the challenges associated with their adaptation towards detection of fluid-specific analytes.

  1. Three-dimensional Computational Fluid Dynamics Investigation of a Spinning Helicopter Slung Load

    NASA Technical Reports Server (NTRS)

    Theorn, J. N.; Duque, E. P. N.; Cicolani, L.; Halsey, R.

    2005-01-01

    After performing steady-state Computational Fluid Dynamics (CFD) calculations using OVERFLOW to validate the CFD method against static wind-tunnel data of a box-shaped cargo container, the same setup was used to investigate unsteady flow with a moving body. Results were compared to flight test data previously collected in which the container is spinning.

  2. Bioglass implant-coating interactions in synthetic physiological fluids with varying degrees of biomimicry.

    PubMed

    Popa, A C; Stan, G E; Husanu, M A; Mercioniu, I; Santos, L F; Fernandes, H R; Ferreira, Jmf

    2017-01-01

    Synthetic physiological fluids are currently used as a first in vitro bioactivity assessment for bone grafts. Our understanding about the interactions taking place at the fluid-implant interface has evolved remarkably during the last decade, and does not comply with the traditional International Organization for Standardization/final draft International Standard 23317 protocol in purely inorganic simulated body fluid. The advances in our knowledge point to the need of a true paradigm shift toward testing physiological fluids with enhanced biomimicry and a better understanding of the materials' structure-dissolution behavior. This will contribute to "upgrade" our vision of entire cascades of events taking place at the implant surfaces upon immersion in the testing media or after implantation. Starting from an osteoinductive bioglass composition with the ability to alleviate the oxidative stress, thin bioglass films with different degrees of polymerization were deposited onto titanium substrates. Their biomineralization activity in simulated body fluid and in a series of new inorganic-organic media with increasing biomimicry that more closely simulated the human intercellular environment was compared. A comprehensive range of advanced characterization tools (scanning electron microscopy; grazing-incidence X-ray diffraction; Fourier-transform infrared, micro-Raman, energy-dispersive, X-ray photoelectron, and surface-enhanced laser desorption/ionization time-of-flight mass spectroscopies; and cytocompatibility assays using mesenchymal stem cells) were used. The information gathered is very useful to biologists, biophysicists, clinicians, and material scientists with special interest in teaching and research. By combining all the analyses, we propose herein a step forward toward establishing an improved unified protocol for testing the bioactivity of implant materials.

  3. Monitoring hydration status pre- and post-training among university athletes using urine color and weight loss indicators.

    PubMed

    Webb, Marquitta C; Salandy, Sinead T; Beckford, Safiya E

    2016-01-01

    To investigate the hydration status pre- and post-training among university athletes using urine color and weight loss as indicators. Participants were 52 university athletes training for campus games in a developing country. Pre- and post-training urine specimens were compared with a standard urine color scale. Paired t tests were used to compare urine color and difference in body mass pre- and post-training. The mean age of the athletes was 22.87 ± 3.21. A statistically significance difference (p < .01) was observed between pre- (4.31 ± 1.75) and post- (5.67 ± 1.45) training urine color values for males. Hydration status and weight post-training were statistically significantly different both at the level of p < .01. The results suggest that there is a link between urine color and body mass difference among the student athletes tested. Exercise increases hypohydration due to fluid losses, and therefore attention should be given to fluid supplementation and individualization of fluid intake for each athlete.

  4. Stress testing of electrically active FlexMEAs with simultaneous electrical recording in fluidic environment: Introduction of a new measurement setup

    NASA Astrophysics Data System (ADS)

    Westerhausen, Markus; Martin, Tanja; Kappel, Marcel; Hofmann, Boris

    2018-02-01

    We present a measurement setup consisting of two fluid-filled pressure chambers to mimic the mechanical stress likely to that of small body movements on biomedical flexible micro-electrode arrays for the analysis of various degradation mechanisms. Our main goal was the simulation of micro-motions in fluid conditions, while maintaining an electric access to the device. These micro-motions would be likely to those occurring in the human body caused by the intracranial pressure in magnitudes of 7-25 mmHg, which translates to a fluid pressure of 9-33 mbar. Furthermore, severe mechanical stress can be administered to the samples under the previously mentioned environment. Therefore, a flexible, polyimide-based sample with various metal test structures was fabricated and analyzed in the presented measurement setup. A comparison of the elongation of the sample's surface as a function of the applied hydrostatic pressure is given with computer simulations.

  5. 21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Alpha-1-antichymotrypsin immunological test system....5080 Alpha-1-antichymotrypsin immunological test system. (a) Identification. An alpha-1... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1...

  6. 21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Alpha-1-antichymotrypsin immunological test system....5080 Alpha-1-antichymotrypsin immunological test system. (a) Identification. An alpha-1... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1...

  7. 21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Alpha-1-antichymotrypsin immunological test system....5080 Alpha-1-antichymotrypsin immunological test system. (a) Identification. An alpha-1... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1...

  8. A randomized, double crossover study to investigate the influence of saline infusion on sleep apnea severity in men.

    PubMed

    Yadollahi, Azadeh; Gabriel, Joseph M; White, Laura H; Taranto Montemurro, Luigi; Kasai, Takatoshi; Bradley, T Douglas

    2014-10-01

    Obstructive sleep apnea (OSA) is commoner in patients with fluid-retaining states than in those without fluid retention, in men than in women, and worsens with aging. In men, OSA severity is related to the amount of fluid shifting out of the legs overnight, but a cause-effect relationship is not established. Our objective was to test the hypothesis that mimicking fluid overload during sleep would increase severity of OSA more in older (≥ 40 years) than in younger men (< 40 years). Randomized, single-blind, double crossover study. Research sleep laboratory. Seven older and 10 younger men with non-severe or no sleep apnea, matched for body mass index. During the control arm, normal saline was infused to keep the vein open. During intervention, subjects received an intravenous bolus of normal saline (22 mL/kg body weight) after sleep onset while they were wearing compression stockings to prevent fluid accumulation in the legs. Compared to younger men, infusion of similar amounts of saline in older men caused a greater increase in neck circumference (P < 0.05) and in the AHI (32.2 ± 22.1 vs. 2.2 ± 7.1, P = 0.002). Older men are more susceptible to the adverse effects of intravenous fluid loading on obstructive sleep apnea severity than younger men. This may be due to age-related differences in the amount of fluid accumulating in the neck or upper airway collapsibility in response to intravenous fluid loading. These possibilities remain to be tested in future studies. © 2014 Associated Professional Sleep Societies, LLC.

  9. Spinning fluids reactor

    DOEpatents

    Miller, Jan D; Hupka, Jan; Aranowski, Robert

    2012-11-20

    A spinning fluids reactor, includes a reactor body (24) having a circular cross-section and a fluid contactor screen (26) within the reactor body (24). The fluid contactor screen (26) having a plurality of apertures and a circular cross-section concentric with the reactor body (24) for a length thus forming an inner volume (28) bound by the fluid contactor screen (26) and an outer volume (30) bound by the reactor body (24) and the fluid contactor screen (26). A primary inlet (20) can be operatively connected to the reactor body (24) and can be configured to produce flow-through first spinning flow of a first fluid within the inner volume (28). A secondary inlet (22) can similarly be operatively connected to the reactor body (24) and can be configured to produce a second flow of a second fluid within the outer volume (30) which is optionally spinning.

  10. Analysis of some chosen elements of cerebrospinal fluid and serum in amyotrophic lateral sclerosis patients by total reflection X-ray fluorescence

    NASA Astrophysics Data System (ADS)

    Ostachowicz, B.; Lankosz, M.; Tomik, B.; Adamek, D.; Wobrauschek, P.; Streli, C.; Kregsamer, P.

    2006-11-01

    Trace elements play an important role in the human central nervous system. Significant variations of the concentration of trace elements in body fluids may occur in neurodegenerative diseases. In the present work an investigation of the elemental composition of the serum, and the cerebrospinal fluid in amyotrophic lateral sclerosis patients and a control group was performed. For the analysis of the body fluids Total reflection X-ray Fluorescence (TXRF) spectrometry was used. The samples were taken during routine diagnostic procedures. Na, Mg, Cl, K, Ca, Cu, Zn, and Br were determined in both fluids. In order to validate the results of analysis a serum standard reference material was measured. A t-test was applied to check if the mean concentrations of the elements are different for ALS and the control group. For the serum samples higher values for Br were found in the ALS group, for the cerebrospinal fluid lower values of Na, Mg and Zn as well as higher Ca values were found in the ALS group compared to the control group.

  11. The extensional rheology of non-Newtonian materials

    NASA Technical Reports Server (NTRS)

    Spiegelberg, Stephen H.; Gaudet, Samuel; Mckinley, Gareth H.

    1994-01-01

    It has been proposed to measure the extensional viscosity function of a non-Newtonian polymer solution in a reduced gravity environment as part of the Advanced Fluid Module. In ground-based extensional measurements, the no-sip boundary condition at solid-fluid interfaces always result in appreciable shear gradients in the test fluid; however the removal of gravitational body forces permits controlled extensional deformation of containerless test samples and the first unambiguous measurements of this kind. Imperative to successful implementation of this experiment is the generation and subsequent deformation of a stable cylindrical column of test fluid. A study of the generation and deformation of liquid bridges demonstrates that Newtonian liquid bridges undergo capillary breakup as anticipated when stretched beyond a critical aspect ratio; non-Newtonian liquid bridges, however, are stabilized by the strain-hardening phenomenon exhibited by these materials. Numerical simulations of Newtonian breakup are compared with experimental results, and show that previous ground-based attempts at measuring the extensional viscosity of Newtonian fluids are of limited accuracy.

  12. Duration of time on shift before accidental blood or body fluid exposure for housestaff, nurses, and technicians.

    PubMed

    Green-McKenzie, Judith; Shofer, Frances S

    2007-01-01

    Shift work has been found to be associated with an increased rate of errors and accidents among healthcare workers (HCWs), but the effect of shift work on accidental blood and body fluid exposure sustained by HCWs has not been well characterized. To determine the duration of time on shift before accidental blood and body fluid exposure in housestaff, nurses, and technicians and the proportion of housestaff who sustain a blood and body fluid exposure after 12 hours on duty. This retrospective, descriptive study was conducted during a 24-month period at a large urban teaching hospital. Participants were HCWs who sustained an accidental blood and body fluid exposure. Housestaff were on duty significantly longer than both nursing staff (P=.02) and technicians (P<.0001) before accidental blood and body fluid exposure. Half of the blood and body fluid exposures sustained by housestaff occurred after being on duty 8 hours or more, and 24% were sustained after being on duty 12 hours or more. Of all HCWs, 3% reported an accidental blood and body fluid exposure, with specific rates of 7.9% among nurses, 9.4% among housestaff, and 3% among phlebotomists. Housestaff were significantly more likely to have longer duration of time on shift before blood and body fluid exposure than were the other groups. Almost one-quarter of accidental blood and body fluid exposures to housestaff were incurred after they had been on duty for 12 hours or more. Housestaff sustained a higher rate of accidental blood and body fluid exposures than did nursing staff and technicians.

  13. The evaluation and validation of Phadebas® paper as a presumptive screening tool for saliva on forensic exhibits.

    PubMed

    Wornes, Danielle J; Speers, Samuel J; Murakami, Julie A

    2018-07-01

    The Phadebas ® Forensic Press Test is routinely used for the detection of saliva. However, assessment of the use of Phadebas ® paper for this purpose has not been studied extensively. The suitability of Phadebas ® paper as a presumptive screening tool for saliva on forensic exhibits, was investigated by analysing the following: (1) sensitivity, (2) specificity, (3) effects of temperature on sensitivity and specificity, (4) detection of saliva in mixed body fluid samples, and (5) influence of substrate porosity. The results of this study demonstrated that Phadebas ® paper is more sensitive to α-amylase activity and less specific for saliva than previously reported. The use of an examination temperature of 37°C had no effect on sensitivity, but increased the incidence of cross-reactivity with other forensically relevant body fluid stains. Blood, urine and vaginal secretions can inhibit the detection of α-amylase activity with Phadebas ® paper in mixed stains of saliva and body fluid. Substrate porosity is a weak predictor for the time taken for a saliva stain to achieve a strong positive result on Phadebas ® paper. Overall, this study demonstrated that the Phadebas ® Forensic Press Test has limitations as a presumptive test for the accurate identification of saliva. Copyright © 2018 Elsevier B.V. All rights reserved.

  14. Practices and impacts post-exposure to blood and body fluid in operating room nurses: A cross-sectional study.

    PubMed

    Kasatpibal, Nongyao; Whitney, JoAnne D; Katechanok, Sadubporn; Ngamsakulrat, Sukanya; Malairungsakul, Benjawan; Sirikulsathean, Pinyo; Nuntawinit, Chutatip; Muangnart, Thanisara

    2016-05-01

    Improper or inadequate actions taken after blood and body fluid exposures place individuals at risk for infection with bloodborne pathogens. This has potential, significant impact for health and well-being. To evaluate the practices and the personal impact experienced following blood and body fluid exposures among operating room nurses. A cross-sectional, multi-center study. Government and private hospitals from all parts of Thailand. Operating room nurses from 247 hospitals. A questionnaire eliciting responses on characteristics, post-exposure practices, and impacts was sent to 2500 operating room nurses. Usable questionnaires were returned by 2031 operating room nurses (81.2%). Of these 1270 had experience with blood and body fluid exposures (62.5%). Most operating room nurses did not report blood and body fluid exposures (60.9%). The major reasons of underreporting were low risk source (40.2%) and belief that they were not important to report (16.3%). Improper post-exposure practices were identified, 9.8% did not clean exposure area immediately, 18.0% squeezed out the wound, and 71.1% used antiseptic solution for cleansing a puncture wound. Post-exposure, 58.5% of them sought counseling, 16.3% took antiretroviral prophylaxis, 23.8% had serologic testing for hepatitis B and 43.1% for hepatitis C. The main personal impacts were anxiety (57.7%), stress (24.2%), and insomnia (10.2%). High underreporting, inappropriate post-exposure practices and impacts of exposure were identified from this study. Comprehensive education and effective training of post-exposure management may be keys to resolving these important problems. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Comparative analysis of expert and machine-learning methods for classification of body cavity effusions in companion animals.

    PubMed

    Hotz, Christine S; Templeton, Steven J; Christopher, Mary M

    2005-03-01

    A rule-based expert system using CLIPS programming language was created to classify body cavity effusions as transudates, modified transudates, exudates, chylous, and hemorrhagic effusions. The diagnostic accuracy of the rule-based system was compared with that produced by 2 machine-learning methods: Rosetta, a rough sets algorithm and RIPPER, a rule-induction method. Results of 508 body cavity fluid analyses (canine, feline, equine) obtained from the University of California-Davis Veterinary Medical Teaching Hospital computerized patient database were used to test CLIPS and to test and train RIPPER and Rosetta. The CLIPS system, using 17 rules, achieved an accuracy of 93.5% compared with pathologist consensus diagnoses. Rosetta accurately classified 91% of effusions by using 5,479 rules. RIPPER achieved the greatest accuracy (95.5%) using only 10 rules. When the original rules of the CLIPS application were replaced with those of RIPPER, the accuracy rates were identical. These results suggest that both rule-based expert systems and machine-learning methods hold promise for the preliminary classification of body fluids in the clinical laboratory.

  16. Forensics Investigator

    MedlinePlus

    ... specialize in areas such as DNA analysis or firearm examination, performing tests on weapons and substances like ... often are exposed to human body fluids and firearms. However, these working conditions pose little risk, if ...

  17. In-vitro characterization of stress corrosion cracking of aluminium-free magnesium alloys for temporary bio-implant applications.

    PubMed

    Choudhary, Lokesh; Singh Raman, R K; Hofstetter, Joelle; Uggowitzer, Peter J

    2014-09-01

    The complex interaction between physiological stresses and corrosive human body fluid may cause premature failure of metallic biomaterials due to the phenomenon of stress corrosion cracking. In this study, the susceptibility to stress corrosion cracking of biodegradable and aluminium-free magnesium alloys ZX50, WZ21 and WE43 was investigated by slow strain rate tensile testing in a simulated human body fluid. Slow strain rate tensile testing results indicated that each alloy was susceptible to stress corrosion cracking, and this was confirmed by fractographic features of transgranular and/or intergranular cracking. However, the variation in alloy susceptibility to stress corrosion cracking is explained on the basis of their electrochemical and microstructural characteristics. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Influence of circumferential notch and fatigue crack on the mechanical integrity of biodegradable magnesium-based alloy in simulated body fluid.

    PubMed

    Bobby Kannan, M; Singh Raman, R K; Witte, F; Blawert, C; Dietzel, W

    2011-02-01

    Applications of magnesium alloys as biodegradable orthopaedic implants are critically dependent on the mechanical integrity of the implant during service. In this study, the mechanical integrity of an AZ91 magnesium alloy was studied using a constant extension rate tensile (CERT) method. The samples in two different geometries that is, circumferentially notched (CN), and circumferentially notched and fatigue cracked (CNFC), were tested in air and in simulated body fluid (SBF). The test results show that the mechanical integrity of the AZ91 magnesium alloy decreased substantially (∼50%) in both the CN and CNFC samples exposed to SBF. Fracture surface analysis revealed secondary cracks suggesting stress corrosion cracking susceptibility of the alloy in SBF. Copyright © 2010 Wiley Periodicals, Inc.

  19. Detecting and collecting traces of semen and blood from outdoor crime scenes using crime scene dogs and presumptive tests.

    PubMed

    Skalleberg, A G; Bouzga, M M

    2016-07-01

    In 2009, the Norwegian police academy educated their first crime scene dogs, trained to locate traces of seminal fluid and blood in outdoor and indoor crime scenes. The Department of Forensic Biology was invited to take part in this project to educate the police in specimen collection and presumptive testing. We performed tests where seminal fluid was deposited on different outdoor surfaces from between one hour to six days, and blood on coniferous ground from between one hour to two days. For both body fluids the tests were performed with three different volumes. The crime scene dogs located the stains, and acid phosphatase/tetrabasebariumperoxide was used as presumptive tests before collection for microscopy and DNA analysis. For seminal fluid the dogs were able to locate all stains for up to two days and only the largest volume after four days. The presumptive tests confirmed the dog's detection. By microscopy we were able to detect spermatozoa for the smallest volumes up to 32h, and for the largest volume up to 4 days, and the DNA results are in correlation to these findings. For blood all the stains were detected by the dogs, except the smallest volume of blood after 32h. The presumptive tests confirmed the dog's detection. We were able to get DNA results for most stains in the timeframe 1-48h with the two largest volumes. The smallest volume shows diversities between the parallels, with no DNA results after 24h. These experiments show that it is critical that body fluids are collected within a timeframe to be able to get a good DNA result, preferably within the first 24-48h. Other parameters that should be taken into account are the weather conditions, type of surfaces and specimen collection. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  20. 21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...

  1. 21 CFR 880.6740 - Vacuum-powered body fluid suction apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vacuum-powered body fluid suction apparatus. 880... Personal Use Miscellaneous Devices § 880.6740 Vacuum-powered body fluid suction apparatus. (a) Identification. A vacuum-powered body fluid suction apparatus is a device used to aspirate, remove, or sample...

  2. Human body fluid proteome analysis

    PubMed Central

    Hu, Shen; Loo, Joseph A.; Wong, David T.

    2010-01-01

    The focus of this article is to review the recent advances in proteome analysis of human body fluids, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, and amniotic fluid, as well as its applications to human disease biomarker discovery. We aim to summarize the proteomics technologies currently used for global identification and quantification of body fluid proteins, and elaborate the putative biomarkers discovered for a variety of human diseases through human body fluid proteome (HBFP) analysis. Some critical concerns and perspectives in this emerging field are also discussed. With the advances made in proteomics technologies, the impact of HBFP analysis in the search for clinically relevant disease biomarkers would be realized in the future. PMID:17083142

  3. Human body fluid proteome analysis.

    PubMed

    Hu, Shen; Loo, Joseph A; Wong, David T

    2006-12-01

    The focus of this article is to review the recent advances in proteome analysis of human body fluids, including plasma/serum, urine, cerebrospinal fluid, saliva, bronchoalveolar lavage fluid, synovial fluid, nipple aspirate fluid, tear fluid, and amniotic fluid, as well as its applications to human disease biomarker discovery. We aim to summarize the proteomics technologies currently used for global identification and quantification of body fluid proteins, and elaborate the putative biomarkers discovered for a variety of human diseases through human body fluid proteome (HBFP) analysis. Some critical concerns and perspectives in this emerging field are also discussed. With the advances made in proteomics technologies, the impact of HBFP analysis in the search for clinically relevant disease biomarkers would be realized in the future.

  4. The quantification of body fluid allostasis during exercise.

    PubMed

    Tam, Nicholas; Noakes, Timothy D

    2013-12-01

    The prescription of an optimal fluid intake during exercise has been a controversial subject in sports science for at least the past decade. Only recently have guidelines evolved from 'blanket' prescriptions to more individualised recommendations. Currently the American College of Sports Medicine advise that sufficient fluid should be ingested to ensure that body mass (BM) loss during exercise does not exceed >2 % of starting BM so that exercise-associated medical complications will be avoided. Historically, BM changes have been used as a surrogate for fluid loss during exercise. It would be helpful to accurately determine fluid shifts in the body in order to provide physiologically appropriate fluid intake advice. The measurement of total body water via D2O is the most accurate measure to detect changes in body fluid content; other methods, including bioelectrical impedance, are less accurate. Thus, the aim of this review is to convey the current understanding of body fluid allostasis during exercise when drinking according to the dictates of thirst (ad libitum). This review examines the basis for fluid intake prescription with the use of BM, the concepts of 'voluntary and involuntary dehydration' and the major routes by which the body gains and loses fluid during exercise.

  5. 21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...

  6. 21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...

  7. 21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...

  8. 21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...

  9. 21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...

  10. 21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...

  11. 21 CFR 866.5890 - Inter-alpha trypsin inhibitor immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... measure by immunochemical techniques the inter-alpha trypsin inhibitor (a protein) in serum and other body fluids. Measurement of inter-alpha trypsin inhibitor may aid in the diagnosis of acute bacterial...

  12. 21 CFR 866.5200 - Carbonic anhydrase B and C immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological Test... immunochemical techniques specific carbonic anhydrase protein molecules in serum and other body fluids. Measurements of carbonic anhydrase B and C aid in the diagnosis of abnormal hemoglobin metabolism. (b...

  13. Freeform fluidics

    DOEpatents

    Dehoff, Ryan R; Lind, Randall F; Love, Lonnie L; Peter, William H; Richardson, Bradley S

    2015-02-10

    A robotic, prosthetic or orthotic member includes a body formed of a solidified metallic powder. At least one working fluid cylinder is formed in the body. A piston is provided in the working fluid cylinder for pressurizing a fluid in the cylinder. At least one working fluid conduit receives the pressurized fluid from the cylinder. The body, working fluid cylinder and working fluid conduit have a unitary construction. A method of making a robotic member is also disclosed.

  14. Blade for a gas turbine

    DOEpatents

    Liang, George

    2010-10-26

    A blade is provided for a gas turbine. The blade comprises a main body comprising a cooling fluid entrance channel; a cooling fluid collector in communication with the cooling fluid entrance channel; a plurality of side channels extending through an outer wall of the main body and communicating with the cooling fluid collector and a cooling fluid cavity; a cooling fluid exit channel communicating with the cooling fluid cavity; and a plurality of exit bores extending from the cooling fluid exit channel through the main body outer wall.

  15. Historical Review of Lower Body Negative Pressure Research in Space Medicine.

    PubMed

    Campbell, Mark R; Charles, John B

    2015-07-01

    Cephalad redistribution of intravascular and extravascular fluid occurs as a result of weightlessness during spaceflight. This provokes cardiovascular, cardiopulmonary, and autonomic nervous system responses. The resulting altered functional state can result in orthostatic hypotension and intolerance upon landing and return to a gravity environment. In-flight lower body negative pressure (LBNP) transiently restores normal body fluid distribution. Early in the U.S. space program, LBNP was devised as a way to test for orthostatic intolerance. With the development of the Skylab Program and longer duration spaceflight, it was realized that it could provide a method of monitoring orthostatic intolerance in flight and predicting the post-landing orthostatic response. LBNP was also investigated not only as an in-flight cardiovascular orthostatic stress test, but also as a countermeasure to cardiovascular deconditioning on Soviet space stations, Skylab, and the Shuttle. It is still being used by the Russian program on the International Space Station as an end-of-flight countermeasure.

  16. Detection of fungal DNA in human body fluids and tissues during a multistate outbreak of fungal meningitis and other infections.

    PubMed

    Gade, Lalitha; Scheel, Christina M; Pham, Cau D; Lindsley, Mark D; Iqbal, Naureen; Cleveland, Angela Ahlquist; Whitney, Anne M; Lockhart, Shawn R; Brandt, Mary E; Litvintseva, Anastasia P

    2013-05-01

    Exserohilum rostratum was the major cause of an outbreak of fungal infections linked to injections of contaminated methylprednisolone acetate. Because almost 14,000 persons were exposed to product that was possibly contaminated with multiple fungal pathogens, there was unprecedented need for a rapid throughput diagnostic test that could detect both E. rostratum and other unusual agents of fungal infection. Here we report development of a novel PCR test that allowed for rapid and specific detection of fungal DNA in cerebrospinal fluid (CSF), other body fluids and tissues of infected individuals. The test relied on direct purification of free-circulating fungal DNA from fluids and subsequent PCR amplification and sequencing. Using this method, we detected Exserohilum rostratum DNA in 123 samples from 114 case-patients (28% of 413 case-patients for whom 627 samples were available), and Cladosporium DNA in one sample from one case-patient. PCR with novel Exserohilum-specific ITS-2 region primers detected 25 case-patients with samples that were negative using broad-range ITS primers. Compared to fungal culture, this molecular test was more sensitive: of 139 case-patients with an identical specimen tested by culture and PCR, E. rostratum was recovered in culture from 19 (14%), but detected by PCR in 41 (29%), showing a diagnostic sensitivity of 29% for PCR compared to 14% for culture in this patient group. The ability to rapidly confirm the etiologic role of E. rostratum in these infections provided an important contribution in the public health response to this outbreak.

  17. 21 CFR 866.5080 - Alpha-1-antichymotrypsin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... immunochemical techniques alpha-1-antichymotrypsin (a protein) in serum, other body fluids, and tissues. Alpha-1-antichymotrypsin helps protect tissues against proteolytic (protein-splitting) enzymes released during infection...

  18. Utility of point of care test devices for infectious disease testing of blood and oral fluid and application to rapid testing in the field

    NASA Astrophysics Data System (ADS)

    Lee, Stephen R.; Kardos, Keith W.; Yearwood, Graham D.; Guillon, Geraldine B.; Kurtz, Lisa A.; Mokkapati, Vijaya K.

    2008-04-01

    Rapid, point of care (POC) testing has been increasingly deployed as an aid in the diagnosis of infectious disease, due to its ability to deliver rapid, actionable results. In the case of HIV, a number of rapid test devices have been FDA approved and CLIA-waived in order to enable diagnosis of HIV infection outside of traditional laboratory settings. These settings include STD clinics, community outreach centers and mobile testing units, as well as identifying HIV infection among pregnant women and managing occupational exposure to infection. The OraQuick ® rapid test platform has been widely used to identify HIV in POC settings, due to its simplicity, ease of use and the ability to utilize oral fluid as an alternative specimen to blood. More recently, a rapid test for antibodies to hepatitis C virus (HCV) has been developed on the same test platform which uses serum, plasma, finger-stick blood, venous blood and oral fluid. Clinical testing using this POC test device has shown that performance is equivalent to state of the art, laboratory based tests. These devices may be suitable for rapid field testing of blood and other body fluids for the presence of infectious agents.

  19. Occurrence of tetrodotoxin-binding high molecular weight substances in the body fluid of shore crab (Hemigrapsus sanguineus).

    PubMed

    Shiomi, K; Yamaguchi, S; Kikuchi, T; Yamamori, K; Matsui, T

    1992-12-01

    The shore crab (Hemigrapsus sanguineus) is highly resistant to tetrodotoxin (TTX) although it contains no detectable amount of TTX (less than 5 MU/g, where 1 MU is defined as the amount of TTX killing a 20 g mouse in 30 min). Its body fluid was examined for neutralizing effects against the lethal activity of TTX. When the mixture of the body fluid and TTX was injected i.p. into mice, the lethal activity of TTX was significantly reduced; 1 ml of the body fluid was evaluated to neutralize 3.6-4.0 MU of TTX. Higher neutralizing activity (7.2-12.5 MU/ml of the body fluid) was exhibited by i.v. administration of the body fluid into mice before or after i.p. challenge of TTX. The lethal effect of paralytic shellfish poisons was not counteracted by the body fluid. Analysis by gel filtration on Sepharose 6B revealed that the body fluid contained TTX-binding high mol. wt substances (> 2,000,000) responsible for the neutralizing activity of the body fluid against TTX, which accounts for the high resistibility of the crab to TTX. When the crude toxin extracted from the liver of puffer (Takifugu niphobles) was mixed with the body fluid and chromatographed on Sepharose 6B, almost pure TTX was obtained from the fractions containing the TTX-binding high mol. wt substances, suggesting that the TTX-binding high mol. wt substances could be useful in purification of TTX from biological samples.

  20. A study on the tensile properties of silicone rubber/polypropylene fibers/silica hybrid nanocomposites.

    PubMed

    Ziraki, Sahar; Zebarjad, Seyed Mojtaba; Hadianfard, Mohammad Jafar

    2016-04-01

    Metacarpophalangeal joint implants have been usually made of silicone rubber. In the current study, silica nano particles and polypropylene fibers were added to silicone rubber to improve silicone properties. The effect of the addition of silica nano particles and polypropylene fibers on the tensile behavior of the resultant composites were investigated. Composite samples with different content of PP fibers and Silica nano particles (i. e. 0, 1 and 2wt%) as well as the hybrid composite of silicone rubber with 1wt% SiO2 and 1wt% PP fiber were prepared. Tensile tests were done at constant cross head speed. To study the body fluid effect on the mechanical properties of silicone rubber composites, samples soaked in simulated body fluid (SBF) at 37°C were also tested. The morphology of the samples were studied by scanning electron microscope. Results of analysis revealed that an increase in PP fibers and silica nano particles content to 2wt%, increases the tensile strength of silicone rubber of about 75% and 42% respectively. It was found out that the strength of the samples decreases after being soaked in simulated body fluid, though composites with PP fibers as the reinforcement showed less property degradation. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Current Applications of Chromatographic Methods in the Study of Human Body Fluids for Diagnosing Disorders.

    PubMed

    Jóźwik, Jagoda; Kałużna-Czaplińska, Joanna

    2016-01-01

    Currently, analysis of various human body fluids is one of the most essential and promising approaches to enable the discovery of biomarkers or pathophysiological mechanisms for disorders and diseases. Analysis of these fluids is challenging due to their complex composition and unique characteristics. Development of new analytical methods in this field has made it possible to analyze body fluids with higher selectivity, sensitivity, and precision. The composition and concentration of analytes in body fluids are most often determined by chromatography-based techniques. There is no doubt that proper use of knowledge that comes from a better understanding of the role of body fluids requires the cooperation of scientists of diverse specializations, including analytical chemists, biologists, and physicians. This article summarizes current knowledge about the application of different chromatographic methods in analyses of a wide range of compounds in human body fluids in order to diagnose certain diseases and disorders.

  2. Medical Support and Findings of the Skylab Program

    NASA Technical Reports Server (NTRS)

    Johnston, Richard S.; Dietlein, Lawrence F.

    1975-01-01

    Specific equipment used in carrying out Skylab medical experiments is outlined and illustrated. Also included are reviews of the techniques, frequency, and protocols of the tests designed to study the long term effects of weightlessness on the human body. In-flight investigations were an evaluation of the cardiovascular system, a study of metabolic activity, investigations in the field of neurophysiology, the determination of changes in body fluids, a precise measurement of total body metabolism, and a study of crew performance by use of a time and motion experiment. Significant data obtained from in-flight and postflight tests are outlined.

  3. Chloride - urine test

    MedlinePlus

    ... of a condition that affects body fluids or acid-base balance. Normal Results The normal range is 110 ... in the clinical evaluation of electrolyte, water, and acid-base disorders. In: Alpern RJ, Moe OW, Caplan M, ...

  4. Bioglass implant-coating interactions in synthetic physiological fluids with varying degrees of biomimicry

    PubMed Central

    Popa, AC; Stan, GE; Husanu, MA; Mercioniu, I; Santos, LF; Fernandes, HR; Ferreira, JMF

    2017-01-01

    Synthetic physiological fluids are currently used as a first in vitro bioactivity assessment for bone grafts. Our understanding about the interactions taking place at the fluid–implant interface has evolved remarkably during the last decade, and does not comply with the traditional International Organization for Standardization/final draft International Standard 23317 protocol in purely inorganic simulated body fluid. The advances in our knowledge point to the need of a true paradigm shift toward testing physiological fluids with enhanced biomimicry and a better understanding of the materials’ structure-dissolution behavior. This will contribute to “upgrade” our vision of entire cascades of events taking place at the implant surfaces upon immersion in the testing media or after implantation. Starting from an osteoinductive bioglass composition with the ability to alleviate the oxidative stress, thin bioglass films with different degrees of polymerization were deposited onto titanium substrates. Their biomineralization activity in simulated body fluid and in a series of new inorganic–organic media with increasing biomimicry that more closely simulated the human intercellular environment was compared. A comprehensive range of advanced characterization tools (scanning electron microscopy; grazing-incidence X-ray diffraction; Fourier-transform infrared, micro-Raman, energy-dispersive, X-ray photoelectron, and surface-enhanced laser desorption/ionization time-of-flight mass spectroscopies; and cytocompatibility assays using mesenchymal stem cells) were used. The information gathered is very useful to biologists, biophysicists, clinicians, and material scientists with special interest in teaching and research. By combining all the analyses, we propose herein a step forward toward establishing an improved unified protocol for testing the bioactivity of implant materials. PMID:28176941

  5. HCG blood test - quantitative

    MedlinePlus

    ... the skin (hematoma) Infection (a slight risk any time the skin is broken) Alternative ... S, Pincus MR, Bluth MH, McPherson RA, Bowne WB, Lee P. Diagnosis and management of cancer using serological and other body fluid ...

  6. Encapsulated proppants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aines, Roger D.; Bourcier, William L.; Duoss, Eric B.

    2018-01-30

    A capsule for carrying a proppant for emplaced in a formation containing formation fluid by a hydraulic fracture operation using a fracturing fluid. The capsule includes a capsule body. The capsule body includes a proppant. There is a surface layer on the capsule body that is permeable to the formation fluid or the fracturing fluid or is permeable to both the formation fluid and the fracturing fluid. The proppant material is dry cement that interacts with the formation fluid or the fracturing fluid or both the formation fluid and the fracturing fluid that migrate through the surface layer and ismore » taken up by the dry cement causing the dry cement to harden.« less

  7. Encapsulated proppants

    DOEpatents

    Aines, Roger D.; Bourcier, William L.; Duoss, Eric B.; Roberts, Jeffery James; Spadaccini, Christopher M.; Stolaroff, Joshuah K.

    2018-01-09

    A capsule for carrying a proppant for emplaced in a formation containing formation fluid by a hydraulic fracture operation using a fracturing fluid. The capsule includes a capsule body. The capsule body includes a proppant. There is a surface layer on the capsule body that is permeable to the formation fluid or the fracturing fluid or is permeable to both the formation fluid and the fracturing fluid. The proppant material is dry cement that interacts with the formation fluid or the fracturing fluid or both the formation fluid and the fracturing fluid that migrate through the surface layer and is taken up by the dry cement causing the dry cement to harden.

  8. 21 CFR 866.5040 - Albumin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... other body fluids. Measurement of albumin aids in the diagnosis of kidney and intestinal diseases. (b... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Albumin immunological test system. 866.5040 Section 866.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  9. 21 CFR 866.5210 - Ceruloplasmin immunolog-ical test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (copper-transporting serum protein) in serum, other body fluids, or tissues. Measurements of ceruloplasmin... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ceruloplasmin immunolog-ical test system. 866.5210 Section 866.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  10. 21 CFR 866.5040 - Albumin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... other body fluids. Measurement of albumin aids in the diagnosis of kidney and intestinal diseases. (b... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Albumin immunological test system. 866.5040 Section 866.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  11. 21 CFR 866.5680 - Myoglobin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... storage protein found in muscle) in serum and other body fluids. Measurement of myoglobin aids in the... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Myoglobin immunological test system. 866.5680 Section 866.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  12. 21 CFR 866.5040 - Albumin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... other body fluids. Measurement of albumin aids in the diagnosis of kidney and intestinal diseases. (b... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Albumin immunological test system. 866.5040 Section 866.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  13. 21 CFR 866.5210 - Ceruloplasmin immunolog-ical test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (copper-transporting serum protein) in serum, other body fluids, or tissues. Measurements of ceruloplasmin... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ceruloplasmin immunolog-ical test system. 866.5210 Section 866.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  14. 21 CFR 866.5210 - Ceruloplasmin immunolog-ical test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (copper-transporting serum protein) in serum, other body fluids, or tissues. Measurements of ceruloplasmin... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ceruloplasmin immunolog-ical test system. 866.5210 Section 866.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  15. 21 CFR 866.5680 - Myoglobin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... storage protein found in muscle) in serum and other body fluids. Measurement of myoglobin aids in the... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Myoglobin immunological test system. 866.5680 Section 866.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  16. 21 CFR 866.5210 - Ceruloplasmin immunolog-ical test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (copper-transporting serum protein) in serum, other body fluids, or tissues. Measurements of ceruloplasmin... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ceruloplasmin immunolog-ical test system. 866.5210 Section 866.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  17. 21 CFR 866.5040 - Albumin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... other body fluids. Measurement of albumin aids in the diagnosis of kidney and intestinal diseases. (b... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Albumin immunological test system. 866.5040 Section 866.5040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  18. 21 CFR 866.5060 - Prealbumin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... protein) in serum and other body fluids. Measurement of prealbumin levels in serum may aid in the... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Prealbumin immunological test system. 866.5060 Section 866.5060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  19. 21 CFR 866.5060 - Prealbumin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... protein) in serum and other body fluids. Measurement of prealbumin levels in serum may aid in the... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Prealbumin immunological test system. 866.5060 Section 866.5060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  20. 21 CFR 866.5680 - Myoglobin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... storage protein found in muscle) in serum and other body fluids. Measurement of myoglobin aids in the... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Myoglobin immunological test system. 866.5680 Section 866.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  1. 21 CFR 866.5680 - Myoglobin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... storage protein found in muscle) in serum and other body fluids. Measurement of myoglobin aids in the... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Myoglobin immunological test system. 866.5680 Section 866.5680 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  2. 21 CFR 866.5060 - Prealbumin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... protein) in serum and other body fluids. Measurement of prealbumin levels in serum may aid in the... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Prealbumin immunological test system. 866.5060 Section 866.5060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  3. 21 CFR 866.5060 - Prealbumin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... protein) in serum and other body fluids. Measurement of prealbumin levels in serum may aid in the... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Prealbumin immunological test system. 866.5060 Section 866.5060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES...

  4. 21 CFR 862.3040 - Alcohol test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Alcohol test system. 862.3040 Section 862.3040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  5. 21 CFR 862.3040 - Alcohol test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... alcohol (e.g., ethanol, methanol, isopropanol, etc.) in human body fluids (e.g., serum, whole blood, and... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Alcohol test system. 862.3040 Section 862.3040 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  6. Fluid shifts during thermal stress with and without fluid replacement

    NASA Technical Reports Server (NTRS)

    Myhre, L. G.; Robinson, S.

    1977-01-01

    Six unacclimatized men rested for 4 hr in a hot, dry environment without fluid replacement (DH). Another group of six men were exposed to the same thermal stress, replacing evaporative fluid loss with warm 0.1% NaCl solution (FRP). Total grams of circulating hemoglobin, determined by CO immediately prior to and again during the last minutes of heat exposure, increased an insignificant 1.6 and 1.3% during DH and FRP, respectively. With DH, body weight loss of 2.6% was accompanied by a 7.8% reduction in calculated plasma volume (PV). Even when body weight was maintained (FRP), PV decreased 2.9% during the heat exposure. Total circulating serum protein did not change as a result of the heat stress with either DH or FRP. In a test-retest series of experiments on four men, DH was not detrimental to sweat rate. It is shown that hemodilution is not a general response to acute heat exposure. The disproportionately large reduction in PV during thermal dehydration is confirmed.

  7. Spectral Mining for Discriminating Blood Origins in the Presence of Substrate Interference via Attenuated Total Reflection Fourier Transform Infrared Spectroscopy: Postmortem or Antemortem Blood?

    PubMed

    Takamura, Ayari; Watanabe, Ken; Akutsu, Tomoko; Ikegaya, Hiroshi; Ozawa, Takeaki

    2017-09-19

    Often in criminal investigations, discrimination of types of body fluid evidence is crucially important to ascertain how a crime was committed. Compared to current methods using biochemical techniques, vibrational spectroscopic approaches can provide versatile applicability to identify various body fluid types without sample invasion. However, their applicability is limited to pure body fluid samples because important signals from body fluids incorporated in a substrate are affected strongly by interference from substrate signals. Herein, we describe a novel approach to recover body fluid signals that are embedded in strong substrate interferences using attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy and an innovative multivariate spectral processing. This technique supported detection of covert features of body fluid signals, and then identified origins of body fluid stains on substrates. We discriminated between ATR FT-IR spectra of postmortem blood (PB) and those of antemortem blood (AB) by creating a multivariate statistics model. From ATR FT-IR spectra of PB and AB stains on interfering substrates (polyester, cotton, and denim), blood-originated signals were extracted by a weighted linear regression approach we developed originally using principal components of both blood and substrate spectra. The blood-originated signals were finally classified by the discriminant model, demonstrating high discriminant accuracy. The present method can identify body fluid evidence independently of the substrate type, which is expected to promote the application of vibrational spectroscopic techniques in forensic body fluid analysis.

  8. Method for detecting and diagnosing disease caused by pathological protein aggregation

    DOEpatents

    Stevens, Fred J.; Myatt, Elizabeth A.; Solomon, Alan

    2000-01-01

    A method is provided for detecting pathological macromolecules in a patient, comprising obtaining body fluid from the patient, pretreating the body fluid, subjecting the pretreated body fluid to size-exclusion chromatography to create an excluded fluid, and analyzing the excluded fluid to detect macromolecules having a predetermined molecular weight. The method also allows for comparing elution spectra with reference spectra of suspect pathologic proteins.

  9. Ultra-fast escape maneuver of an octopus-inspired robot.

    PubMed

    Weymouth, G D; Subramaniam, V; Triantafyllou, M S

    2015-02-02

    We design and test an octopus-inspired flexible hull robot that demonstrates outstanding fast-starting performance. The robot is hyper-inflated with water, and then rapidly deflates to expel the fluid so as to power the escape maneuver. Using this robot we verify for the first time in laboratory testing that rapid size-change can substantially reduce separation in bluff bodies traveling several body lengths, and recover fluid energy which can be employed to improve the propulsive performance. The robot is found to experience speeds over ten body lengths per second, exceeding that of a similarly propelled optimally streamlined rigid rocket. The peak net thrust force on the robot is more than 2.6 times that on an optimal rigid body performing the same maneuver, experimentally demonstrating large energy recovery and enabling acceleration greater than 14 body lengths per second squared. Finally, over 53% of the available energy is converted into payload kinetic energy, a performance that exceeds the estimated energy conversion efficiency of fast-starting fish. The Reynolds number based on final speed and robot length is [Formula: see text]. We use the experimental data to establish a fundamental deflation scaling parameter [Formula: see text] which characterizes the mechanisms of flow control via shape change. Based on this scaling parameter, we find that the fast-starting performance improves with increasing size.

  10. Comparison of Cell Preparations between Commercially Available Filter Cards of the Cytospin with Custom Made Filter Cards.

    PubMed

    Krishnamurthy, Vani; Satish, Suchitha; Doreswamy, Srinivasa Murthy; Vimalambike, Manjunath Gubbanna

    2016-07-01

    Cytological evaluation of body fluids is an important diagnostic technique. Cytocentrifuge has contributed immensely to improve the diagnostic yield of the body fluids. Cytocentrifuge requires a filter card for absorbing the cell free fluid. This is the only consumable which needs to be purchased from the manufacturer at a significant cost. To compare the cell density in cytocentrifuge preparations made from commercially available filter cards with custom made filter cards. This was a prospective analytical study undertaken in department of pathology of a tertiary care centre. A 300 GSM handmade paper with the absorbability similar to the conventional card was obtained and fashioned to suit the filter card slot of the cytospin. Thirty seven body fluids were centrifuged using both conventional and custom made filter card. The cell density was measured as number of cells per 10 high power fields. The median cell density was compared using Mann-Whitney U test. The agreement between the values was analysed using Bland Altman analysis. The median cell count per 10 High power field (HPF) with conventional card was 386 and that with custom made card was 408. The difference was not statistically significant (p = 0.66). There was no significant difference in the cell density and alteration in the morphology between the cell preparations using both the cards. Custom made filter card can be used for cytospin cell preparations of body fluids without loss of cell density or alteration in the cell morphology and at a very low cost.

  11. Flehmen response in bull: role of vaginal mucus and other body fluids of bovine with special reference to estrus.

    PubMed

    Sankar, R; Archunan, G

    2004-07-30

    The present investigation was carried out with a view to evaluate the frequency of Flehmen behaviour in bull in response to body fluids of cows in various stages of the estrous cycle, in the context of estrus detection. The study was performed on free moving bulls under natural conditions. Samples of vaginal mucus, saliva, faeces and milk of pro-estrus, estrus and di-estrus stages collected from donor cows were rubbed individually onto the genital regions of non-estrus animals (dummy cows) and the bulls were observed for 30 min for assessment of Flehmen behaviour. The duration of Flehmen behaviour shown by bulls was maximum towards the dummy cows receiving estrus sample. Such Flehmen behaviour, however, did not occur in bulls in response to the cows receiving samples of other stages. The statistical significance was higher (P < 0.001) in exhibiting repeated Flehmen behaviour towards estrus as compared to those of pro-estrus and di-estrus. Among the various body fluids tested, the exhibition of Flehmen behaviour was significantly higher (P < 0.01) in response to estrus vaginal fluid. No response was observed on dummy cows (control) to which only water was applied on the genital region. The results suggest that vaginal mucus may act as an additional/secondary source along with urine in eliciting copulatary behaviour and executing coitus in bulls during estrus. The results further suggest that in addition to vaginal mucus, other body fluids like saliva, faeces and milk have estrus-related odours and are probably involved in bovine bio-communication.

  12. A subjective evaluation of a drinking system for saturation divers.

    PubMed

    Hope, Arvid; Brekken, Rudolf

    2010-03-01

    Studies have shown that divers may lose large volumes of body fluids in hot water suit (HWS) dives lasting for four hours or longer, and that this dehydration is mainly caused by sweating. Body fluid balance may be impaired and the diver's alertness and power of judgement could be influenced by such imbalance. The main objective of the present study was to obtain a subjective judgement of a drinking system for divers (DSFD) and to obtain information related to body fluid loss during long saturation lock-out dives. Via a suction pipe imbedded in the microphone unit in the oronasal mask, the DSFD makes it possible for the diver to drink while in the water. Ten divers tested the drinking system during 12 saturation lock-out dives lasting on average for 5.5 h. A questionnaire was answered after each dive. The divers drank 21 times (range 5-30 times) during the dives, and the average drinking volume was 1.4 litre (range 1.0-1.5 litre) but only drank 0.04 litre (range 0-0.3 litre) in the bell after diving. The system was easy to operate and preparation and clothing did not cause any delay. The suction pipe did not intrude and the microphone performed excellently. The work in water was not hindered by DSFD and all divers were very satisfied with the drinking system. It was obvious that the need for fluid intake after a dive with DSFD was markedly reduced; another good indication of maintained body fluid balance.

  13. Clostridium difficile and C. difficile Toxin Testing

    MedlinePlus

    ... Blood Ketones Blood Smear Blood Typing Blood Urea Nitrogen (BUN) BNP and NT-proBNP Body Fluid Analysis ... other infections, typically for an extended period, the balance of the normal flora in the digestive tract ...

  14. Shock Waves Mitigation at Blunt Bodies Using Needles and Shells Against a Supersonic Flow

    NASA Technical Reports Server (NTRS)

    Gilinsky, M.; Blankson, I. M.; Sakharov, V. I.; Shvets, A. I.

    2004-01-01

    The paper contains some experimental and numerical simulation test results on cylindrical blunt body drag reduction using thin spikes or shell mounted in front of a body against a supersonic flow. Experimental tests were conducted using the Aeromechanics and Gas Dynamics Laboratory facilities at the Institute of Mechanics of Moscow State University (IMMSU). Numerical simulations utilizing NASA and IM/MSU codes were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory. The main purpose of this research is to examine the efficiency of application of multiple spikes for drag reduction and flow stability at the front of a blunt body in different flight conditions, i.e. Mach number, angle of attack, etc. The principal conclusions of these test results are: multiple spike/needle application leads to decrease of drag reduction benefits by comparison with the case of one central mounted needle at the front of a blunt body, but increase lift benefits.

  15. The use of semi-quantitative tests at Cesarean section delivery for the differentiation of canine fetal fluids from maternal urine on the basis of biochemical characteristics.

    PubMed

    Balogh, Orsolya; Roch, Marie; Keller, Stefanie; Michel, Erika; Reichler, Iris M

    2017-01-15

    In dogs, there is no diagnostic test to identify and differentiate fetal fluids from maternal urine in the event that a clear-yellowish vulvar discharge is observed pre-whelping. The objective of this study was to find a test that could easily and accurately identify rupture of the fetal membranes preceding parturition. Maternal urine, and amniotic fluid (AMF) and allantoic fluid (ALF) from only one fetus per bitch, were collected intraoperatively during Cesarean section. Specific gravity (SG) was analyzed with a refractometer, whereas the presence of leukocytes, protein, glucose, ketones, bilirubin, urobilinogen, nitrite, erythrocyte/hemoglobin (Hb), and the pH were assessed using a urine dipstick (Combur-Test ® ). Combined calcium and magnesium (Ca/Mg) content were evaluated with the Total Hardness Test. The AmniSure test, which detects rupture of fetal membranes in women on the basis of the presence of human placental alpha microglobulin-1, was also performed on canine AMF, ALF, and urine. Data were analyzed using the Fisher's exact test, Wilcoxon signed-rank test, and Pearson's correlation. Sensitivity, specificity, and positive and negative likelihood ratios (LR) were calculated for parameters with significant difference between urine and both fetal fluids. Maternal urine had higher SG and lower leukocyte, protein, Hb, and Ca/Mg content than AMF and ALF. Glucose was more often present in AMF (n = 17) and ALF (n = 12) than in urine (n = 1), whereas ketone bodies were rarely detected in ALF compared with urine. Bilirubin content was higher in urine and ALF than in AMF. AMF pH was less variable and higher than the pH of ALF or urine. The AmniSure was negative in all samples tested. Sensitivity and specificity for SG and for the detection of leukocytes, protein, glucose, Hb, Ca/Mg, and glucose without ketones in urine and fetal fluids were between 42% to 100% and 65% to 100%, respectively. Best positive LR was achieved for the detection of glucose without ketones and best negative LR for SG of 1.022 or less. In conclusion, the AmniSure test, which is used in humans with high diagnostic accuracy, cannot identify AMF and ALF in dogs. On the basis of our results in 26 dogs undergoing Cesarean section, the presence or absence of fetal fluids could be best determined by a positive glucose test without ketone bodies or by SG higher than 1.022, respectively. These tests may serve as additional tools to recognize parturition if clear-yellowish vulvar discharge is present in a term pregnant bitch, but their accuracy and practicability in the clinical setting need to be confirmed. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Identification of body fluid-specific DNA methylation markers for use in forensic science.

    PubMed

    Park, Jong-Lyul; Kwon, Oh-Hyung; Kim, Jong Hwan; Yoo, Hyang-Sook; Lee, Han-Chul; Woo, Kwang-Man; Kim, Seon-Young; Lee, Seung-Hwan; Kim, Yong Sung

    2014-11-01

    DNA methylation, which occurs at the 5'-position of the cytosine in CpG dinucleotides, has great potential for forensic identification of body fluids, because tissue-specific patterns of DNA methylation have been demonstrated, and DNA is less prone to degradation than proteins or RNA. Previous studies have reported several body fluid-specific DNA methylation markers, but DNA methylation differences are sometimes low in saliva and vaginal secretions. Moreover, specific DNA methylation markers in four types of body fluids (blood, saliva, semen, and vaginal secretions) have not been investigated with genome-wide profiling. Here, we investigated novel DNA methylation markers for identification of body fluids for use in forensic science using the Illumina HumanMethylation 450K bead array, which contains over 450,000 CpG sites. Using methylome data from 16 samples of blood, saliva, semen, and vaginal secretions, we first selected 2986 hypermethylated or hypomethylated regions that were specific for each type of body fluid. We then selected eight CpG sites as novel, forensically relevant DNA methylation markers: cg06379435 and cg08792630 for blood, cg26107890 and cg20691722 for saliva, cg23521140 and cg17610929 for semen, and cg01774894 and cg14991487 for vaginal secretions. These eight selected markers were evaluated in 80 body fluid samples using pyrosequencing, and all showed high sensitivity and specificity for identification of the target body fluid. We suggest that these eight DNA methylation markers may be good candidates for developing an effective molecular assay for identification of body fluids in forensic science. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  17. Quantitative body fluid proteomics in medicine - A focus on minimal invasiveness.

    PubMed

    Csősz, Éva; Kalló, Gergő; Márkus, Bernadett; Deák, Eszter; Csutak, Adrienne; Tőzsér, József

    2017-02-05

    Identification of new biomarkers specific for various pathological conditions is an important field in medical sciences. Body fluids have emerging potential in biomarker studies especially those which are continuously available and can be collected by non-invasive means. Changes in the protein composition of body fluids such as tears, saliva, sweat, etc. may provide information on both local and systemic conditions of medical relevance. In this review, our aim is to discuss the quantitative proteomics techniques used in biomarker studies, and to present advances in quantitative body fluid proteomics of non-invasively collectable body fluids with relevance to biomarker identification. The advantages and limitations of the widely used quantitative proteomics techniques are also presented. Based on the reviewed literature, we suggest an ideal pipeline for body fluid analyses aiming at biomarkers discoveries: starting from identification of biomarker candidates by shotgun quantitative proteomics or protein arrays, through verification of potential biomarkers by targeted mass spectrometry, to the antibody-based validation of biomarkers. The importance of body fluids as a rich source of biomarkers is discussed. Quantitative proteomics is a challenging part of proteomics applications. The body fluids collected by non-invasive means have high relevance in medicine; they are good sources for biomarkers used in establishing the diagnosis, follow up of disease progression and predicting high risk groups. The review presents the most widely used quantitative proteomics techniques in body fluid analysis and lists the potential biomarkers identified in tears, saliva, sweat, nasal mucus and urine for local and systemic diseases. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Segment-specific resistivity improves body fluid volume estimates from bioimpedance spectroscopy in hemodialysis patients.

    PubMed

    Zhu, F; Kuhlmann, M K; Kaysen, G A; Sarkar, S; Kaitwatcharachai, C; Khilnani, R; Stevens, L; Leonard, E F; Wang, J; Heymsfield, S; Levin, N W

    2006-02-01

    Discrepancies in body fluid estimates between segmental bioimpedance spectroscopy (SBIS) and gold-standard methods may be due to the use of a uniform value of tissue resistivity to compute extracellular fluid volume (ECV) and intracellular fluid volume (ICV). Discrepancies may also arise from the exclusion of fluid volumes of hands, feet, neck, and head from measurements due to electrode positions. The aim of this study was to define the specific resistivity of various body segments and to use those values for computation of ECV and ICV along with a correction for unmeasured fluid volumes. Twenty-nine maintenance hemodialysis patients (16 men) underwent body composition analysis including whole body MRI, whole body potassium (40K) content, deuterium, and sodium bromide dilution, and segmental and wrist-to-ankle bioimpedance spectroscopy, all performed on the same day before a hemodialysis. Segment-specific resistivity was determined from segmental fat-free mass (FFM; by MRI), hydration status of FFM (by deuterium and sodium bromide), tissue resistance (by SBIS), and segment length. Segmental FFM was higher and extracellular hydration of FFM was lower in men compared with women. Segment-specific resistivity values for arm, trunk, and leg all differed from the uniform resistivity used in traditional SBIS algorithms. Estimates for whole body ECV, ICV, and total body water from SBIS using segmental instead of uniform resistivity values and after adjustment for unmeasured fluid volumes of the body did not differ significantly from gold-standard measures. The uniform tissue resistivity values used in traditional SBIS algorithms result in underestimation of ECV, ICV, and total body water. Use of segmental resistivity values combined with adjustment for body volumes that are neglected by traditional SBIS technique significantly improves estimations of body fluid volume in hemodialysis patients.

  19. Microneedle pH Sensor: Direct, Label-Free, Real-Time Detection of Cerebrospinal Fluid and Bladder pH.

    PubMed

    Mani, Ganesh Kumar; Miyakoda, Kousei; Saito, Asuka; Yasoda, Yutaka; Kajiwara, Kagemasa; Kimura, Minoru; Tsuchiya, Kazuyoshi

    2017-07-05

    Acid-base homeostasis (body pH) inside the body is precisely controlled by the kidneys and lungs and buffer systems, such that even a minor pH change could severely affect many organs. Blood and urine pH tests are common in day-to-day clinical trials and require little effort for diagnosis. There is always a great demand for in vivo testing to understand more about body metabolism and to provide effective diagnosis and therapy. In this article, we report the simple fabrication of microneedle-based direct, label-free, and real-time pH sensors. The reference and working electrodes were Ag/AgCl thick films and ZnO thin films on tungsten (W) microneedles, respectively. The morphological and structural characteristics of microneedles were carefully investigated through various analytical methods. The developed sensor exhibited a Nernstian response of -46 mV/pH. Different conditions were used to test the sensor to confirm their accuracy and stability, such as various buffer solutions, with respect to time, and we compared the reading with commercial pH electrodes. Besides that, the fabricated microneedle sensor ability is proven by in vivo testing in mouse cerebrospinal fluid (CSF) and bladders. The pH sensor procedure reported here is totally reversible, and results were reproducible after several rounds of testing.

  20. Raman spectroscopic signature of vaginal fluid and its potential application in forensic body fluid identification.

    PubMed

    Sikirzhytskaya, Aliaksandra; Sikirzhytski, Vitali; Lednev, Igor K

    2012-03-10

    Traces of human body fluids, such as blood, saliva, sweat, semen and vaginal fluid, play an increasingly important role in forensic investigations. However, a nondestructive, easy and rapid identification of body fluid traces at the scene of a crime has not yet been developed. The obstacles have recently been addressed in our studies, which demonstrated the considerable potential of Raman spectroscopy. In this study, we continued to build a full library of body fluid spectroscopic signatures. The problems concerning vaginal fluid stain identification were addressed using Raman spectroscopy coupled with advanced statistical analysis. Calculated characteristic Raman and fluorescent spectral components were used to build a multidimensional spectroscopic signature of vaginal fluid, which demonstrated good specificity and was able to handle heterogeneous samples from different donors. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  1. 49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...

  2. 49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...

  3. 49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...

  4. 49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...

  5. 49 CFR 40.151 - What are MROs prohibited from doing as part of the verification process?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... should have directed that a test occur. For example, if an employee tells you that the employer misidentified her as the subject of a random test, or directed her to take a reasonable suspicion or post... consider any evidence from tests of urine samples or other body fluids or tissues (e.g., blood or hair...

  6. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues from the Fast Antimicrobial Screen Test to the Kidney Inhibition Swab (KIS(TM)). Here, we describe the use of KIS(TM) test for the detection of penicillin G res...

  7. 21 CFR 866.5630 - Beta-2-microglobulin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... beta-2-microglobulin (a protein molecule) in serum, urine, and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Beta-2-microglobulin immunological test system. 866.5630 Section 866.5630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  8. 21 CFR 866.5400 - Alpha-globulin immuno-logical test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... alpha-globulin (a serum protein) in serum and other body fluids. Measurement of alpha-globulin may aid... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Alpha-globulin immuno-logical test system. 866.5400 Section 866.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  9. 21 CFR 866.5420 - Alpha-1-glycoproteins immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... electrophoresis) in serum and other body fluids. Measurement of specific alpha-1-glycoproteins may aid in the... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Alpha-1-glycoproteins immunological test system. 866.5420 Section 866.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  10. 21 CFR 866.5130 - Alpha-1-antitrypsin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the alpha-1-antitrypsin (a plasma protein) in serum, other body fluids, and tissues. The measurements... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Alpha-1-antitrypsin immunological test system. 866.5130 Section 866.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  11. 21 CFR 866.5350 - Fibrinopeptide A immuno-logical test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... fibrinopeptide A (a blood-clotting factor) in plasma and other body fluids. Measurement of fibrinopeptide A may... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Fibrinopeptide A immuno-logical test system. 866.5350 Section 866.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  12. 21 CFR 866.5630 - Beta-2-microglobulin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... beta-2-microglobulin (a protein molecule) in serum, urine, and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Beta-2-microglobulin immunological test system. 866.5630 Section 866.5630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  13. 21 CFR 866.5130 - Alpha-1-antitrypsin immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the alpha-1-antitrypsin (a plasma protein) in serum, other body fluids, and tissues. The measurements... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Alpha-1-antitrypsin immunological test system. 866.5130 Section 866.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  14. 21 CFR 866.5630 - Beta-2-microglobulin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... beta-2-microglobulin (a protein molecule) in serum, urine, and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Beta-2-microglobulin immunological test system. 866.5630 Section 866.5630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  15. 21 CFR 866.5600 - Low-density lipoprotein immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the low-density lipoprotein in serum and other body fluids. Measurement of low-density lipoprotein in... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Low-density lipoprotein immunological test system. 866.5600 Section 866.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  16. 21 CFR 866.5600 - Low-density lipoprotein immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the low-density lipoprotein in serum and other body fluids. Measurement of low-density lipoprotein in... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Low-density lipoprotein immunological test system. 866.5600 Section 866.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  17. 21 CFR 866.5420 - Alpha-1-glycoproteins immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... electrophoresis) in serum and other body fluids. Measurement of specific alpha-1-glycoproteins may aid in the... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Alpha-1-glycoproteins immunological test system. 866.5420 Section 866.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  18. 21 CFR 866.5350 - Fibrinopeptide A immuno-logical test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... fibrinopeptide A (a blood-clotting factor) in plasma and other body fluids. Measurement of fibrinopeptide A may... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Fibrinopeptide A immuno-logical test system. 866.5350 Section 866.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  19. 21 CFR 866.5130 - Alpha-1-antitrypsin immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the alpha-1-antitrypsin (a plasma protein) in serum, other body fluids, and tissues. The measurements... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Alpha-1-antitrypsin immunological test system. 866.5130 Section 866.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  20. 21 CFR 866.5630 - Beta-2-microglobulin immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... beta-2-microglobulin (a protein molecule) in serum, urine, and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Beta-2-microglobulin immunological test system. 866.5630 Section 866.5630 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  1. 21 CFR 866.5350 - Fibrinopeptide A immuno-logical test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... fibrinopeptide A (a blood-clotting factor) in plasma and other body fluids. Measurement of fibrinopeptide A may... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Fibrinopeptide A immuno-logical test system. 866.5350 Section 866.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  2. 21 CFR 866.5600 - Low-density lipoprotein immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the low-density lipoprotein in serum and other body fluids. Measurement of low-density lipoprotein in... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Low-density lipoprotein immunological test system. 866.5600 Section 866.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  3. 21 CFR 866.5600 - Low-density lipoprotein immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the low-density lipoprotein in serum and other body fluids. Measurement of low-density lipoprotein in... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Low-density lipoprotein immunological test system. 866.5600 Section 866.5600 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  4. 21 CFR 866.5400 - Alpha-globulin immuno-logical test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... alpha-globulin (a serum protein) in serum and other body fluids. Measurement of alpha-globulin may aid... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Alpha-globulin immuno-logical test system. 866.5400 Section 866.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  5. 21 CFR 866.5350 - Fibrinopeptide A immuno-logical test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... fibrinopeptide A (a blood-clotting factor) in plasma and other body fluids. Measurement of fibrinopeptide A may... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Fibrinopeptide A immuno-logical test system. 866.5350 Section 866.5350 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  6. 21 CFR 866.5420 - Alpha-1-glycoproteins immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... electrophoresis) in serum and other body fluids. Measurement of specific alpha-1-glycoproteins may aid in the... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Alpha-1-glycoproteins immunological test system. 866.5420 Section 866.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  7. 21 CFR 866.5130 - Alpha-1-antitrypsin immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the alpha-1-antitrypsin (a plasma protein) in serum, other body fluids, and tissues. The measurements... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Alpha-1-antitrypsin immunological test system. 866.5130 Section 866.5130 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  8. 21 CFR 866.5400 - Alpha-globulin immuno-logical test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... alpha-globulin (a serum protein) in serum and other body fluids. Measurement of alpha-globulin may aid... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Alpha-globulin immuno-logical test system. 866.5400 Section 866.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  9. 21 CFR 866.5420 - Alpha-1-glycoproteins immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... electrophoresis) in serum and other body fluids. Measurement of specific alpha-1-glycoproteins may aid in the... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Alpha-1-glycoproteins immunological test system. 866.5420 Section 866.5420 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  10. 21 CFR 866.5400 - Alpha-globulin immuno-logical test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... alpha-globulin (a serum protein) in serum and other body fluids. Measurement of alpha-globulin may aid... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Alpha-globulin immuno-logical test system. 866.5400 Section 866.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  11. Electrophoretic co-deposition of cellulose nanocrystals-45S5 bioactive glass nanocomposite coatings on stainless steel

    NASA Astrophysics Data System (ADS)

    Chen, Qiang; Yang, Yuyun; Pérez de Larraya, Uxua; Garmendia, Nere; Virtanen, Sannakaisa; Boccaccini, Aldo R.

    2016-01-01

    An organic-inorganic nanocomposite coating consisting of fibrous cellulose nanocrystals and 45S5 bioactive glass, intended as a bioactive surface for bone implants, was developed by a one-step electrophoretic deposition. The composition, surface roughness and wettability of the deposited coatings, influenced by the concentration of each component in the suspension, were controllable as a result of the simplicity of the coating technique. Bioactive glass particles were individually wrapped with porous cellulose layers, forming a porous coating with uniform thickness. Bioactivity test in simulated body fluid revealed a rapid hydroxyapatite formation on the deposited nanocomposite coating. Furthermore, electrochemical test was carried out to understand the corrosion behavior of the deposited coatings during incubation in simulated body fluid. According to the results of this study, the obtained cellulose-bioactive glass coatings with tunable properties represent a promising approach for biofunctionalization of metallic orthopedic implants.

  12. In-vitro biodegradation and corrosion-assisted cracking of a coated magnesium alloy in modified-simulated body fluid.

    PubMed

    Jafari, Sajjad; Singh Raman, R K

    2017-09-01

    A calcium phosphate coating was directly synthesized on AZ91D magnesium (Mg) alloy. Resistance of this coating to corrosion in a modified-simulated body fluid (m-SBF) was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS). Mechanical properties of the bare and coated alloy were investigated using slow strain rate tensile (SSRT) and fatigue testing in air and m-SBF. Very little is reported in the literature on human-body-fluid-assisted cracking of Mg alloys, viz., resistance to corrosion fatigue (CF) and stress corrosion cracking (SCC). This study has a particular emphasis on the effect of bio-compatible coatings on mechanical and electrochemical degradations of Mg alloys for their applications as implants. The results suggest the coating to improve the general as well as pitting corrosion resistance of the alloy. The coating also provides visible improvement in resistance to SCC, but little improvement in CF resistance. This is explained on the basis of pitting behaviour in the presence and absence of the coating. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Corrosion test cell for bipolar plates

    DOEpatents

    Weisbrod, Kirk R.

    2002-01-01

    A corrosion test cell for evaluating corrosion resistance in fuel cell bipolar plates is described. The cell has a transparent or translucent cell body having a pair of identical cell body members that seal against opposite sides of a bipolar plate. The cell includes an anode chamber and an cathode chamber, each on opposite sides of the plate. Each chamber contains a pair of mesh platinum current collectors and a catalyst layer pressed between current collectors and the plate. Each chamber is filled with an electrolyte solution that is replenished with fluid from a much larger electrolyte reservoir. The cell includes gas inlets to each chamber for hydrogen gas and air. As the gases flow into a chamber, they pass along the platinum mesh, through the catalyst layer, and to the bipolar plate. The gas exits the chamber through passageways that provide fluid communication between the anode and cathode chambers and the reservoir, and exits the test cell through an exit port in the reservoir. The flow of gas into the cell produces a constant flow of fresh electrolyte into each chamber. Openings in each cell body is member allow electrodes to enter the cell body and contact the electrolyte in the reservoir therein. During operation, while hydrogen gas is passed into one chamber and air into the other chamber, the cell resistance is measured, which is used to evaluate the corrosion properties of the bipolar plate.

  14. Comparison of Experimental Surface and Flow Field Measurements to Computational Results of the Juncture Flow Model

    NASA Technical Reports Server (NTRS)

    Roozeboom, Nettie H.; Lee, Henry C.; Simurda, Laura J.; Zilliac, Gregory G.; Pulliam, Thomas H.

    2016-01-01

    Wing-body juncture flow fields on commercial aircraft configurations are challenging to compute accurately. The NASA Advanced Air Vehicle Program's juncture flow committee is designing an experiment to provide data to improve Computational Fluid Dynamics (CFD) modeling in the juncture flow region. Preliminary design of the model was done using CFD, yet CFD tends to over-predict the separation in the juncture flow region. Risk reduction wind tunnel tests were requisitioned by the committee to obtain a better understanding of the flow characteristics of the designed models. NASA Ames Research Center's Fluid Mechanics Lab performed one of the risk reduction tests. The results of one case, accompanied by CFD simulations, are presented in this paper. Experimental results suggest the wall mounted wind tunnel model produces a thicker boundary layer on the fuselage than the CFD predictions, resulting in a larger wing horseshoe vortex suppressing the side of body separation in the juncture flow region. Compared to experimental results, CFD predicts a thinner boundary layer on the fuselage generates a weaker wing horseshoe vortex resulting in a larger side of body separation.

  15. Estimates of fluid and energy balances of Apollo 17

    NASA Technical Reports Server (NTRS)

    Johnson, P. C.; Leach, C. S.; Rambaut, P. C.

    1973-01-01

    Fluid and caloric balance has been calculated for the Apollo 17 crew. This included measurement of nitrogen, water, and caloric value of the ingested food and the volume and nitrogen content of the excreted urine and feces. Body composition changes were determined from total body water and extracellular fluid volume differences. The body composition measurements made it possible to divide the weight loss into lean body mass and adipose tissue losses. From this division a caloric equivalent was calculated. These tissue losses indicated that the caloric requirements of the mission were considerably greater than the actual caloric intake. The 3.3 kilo mean loss of body weight represented 1 kilo of lean body mass and 2.3 kilos of adipose tissue. Calculated fluid balance was more positive during the mission than during the control period. These changes are unlike the body composition and fluid balance changes reported in bedrested subjects.

  16. A cyber-physical approach to experimental fluid mechanics

    NASA Astrophysics Data System (ADS)

    Mackowski, Andrew Williams

    This Thesis documents the design, implementation, and use of a novel type of experimental apparatus, termed Cyber-Physical Fluid Dynamics (CPFD). Unlike traditional fluid mechanics experiments, CPFD is a general-purpose technique that allows one to impose arbitrary forces on an object submerged in a fluid. By combining fluid mechanics with robotics, we can perform experiments that would otherwise be incredibly difficult or time-consuming. More generally, CPFD allows a high degree of automation and control of the experimental process, allowing for much more efficient use of experimental facilities. Examples of CPFD's capabilites include imposing a gravitational force in the horizontal direction (allowing a test object to "fall" sideways in a water channel), simulating nonlinear springs for a vibrating fluid-structure system, or allowing a self-propelled body to move forward under its own force. Because experimental parameters (including forces and even the mass of the test object) are defined in software, one can define entire ensembles of experiments to run autonomously. CPFD additionally integrates related systems such as water channel speed control, LDV flow speed measurements, and PIV flowfield measurements. The end result is a general-purpose experimental system that opens the door to a vast array of fluid-structure interaction problems. We begin by describing the design and implementation of CPFD, the heart of which is a high-performance force-feedback control system. Precise measurement of time-varying forces (including removing effects of the test object's inertia) is more critical here than in typical robotic force-feedback applications. CPFD is based on an integration of ideas from control theory, fluid dynamics, computer science, electrical engineering, and solid mechanics. We also describe experiments using the CPFD experimental apparatus to study vortex-induced vibration (VIV) and oscillating-airfoil propulsion. We show how CPFD can be used to simulate a hypothetical VIV energy harvesting device. By replacing standard linear springs with nonlinear ones, we can broaden the system's frequency response. Next, we transition from bluff bodies to unsteady airfoils, where we begin by measuring the thrust and efficiency of an airfoil pitching about its quarter-chord point. Finally, we examine how the propulsive performance of an oscillating airfoil is improved by the addition of passive dynamics.

  17. Generic Long-Range Interactions Between Passive Bodies in an Active Fluid.

    PubMed

    Baek, Yongjoo; Solon, Alexandre P; Xu, Xinpeng; Nikola, Nikolai; Kafri, Yariv

    2018-02-02

    A single nonspherical body placed in an active fluid generates currents via breaking of time-reversal symmetry. We show that, when two or more passive bodies are placed in an active fluid, these currents lead to long-range interactions. Using a multipole expansion, we characterize their leading-order behaviors in terms of single-body properties and show that they decay as a power law with the distance between the bodies, are anisotropic, and do not obey an action-reaction principle. The interactions lead to rich dynamics of the bodies, illustrated by the spontaneous synchronized rotation of pinned nonchiral bodies and the formation of traveling bound pairs. The occurrence of these phenomena depends on tunable properties of the bodies, thus opening new possibilities for self-assembly mediated by active fluids.

  18. Impact on a Compressible Fluid

    NASA Technical Reports Server (NTRS)

    Egorov, L. T.

    1958-01-01

    Upon impact of a solid body on the plane surface of a fluid, there occurs on the vetted surface of the body an abrupt pressure rise which propagates into both media with the speed of sound. Below, we assume the case where the speed of propagation of sound in the body which falls on the surface of the fluid may be regarded as infinitely large in comparison with the speed of propagation of sound in the fluid; that is, we shall assume that the falling body is absolutely rigid. IN this case, the entire relative speed of the motion which takes place at the beginning of the impact is absorbed by the fluid. The hydrodynamic pressures arising thereby are propagated from the contact surface within the fluid with the speed of sound in the form of compression and expansion waves and are gradually damped. After this, they are dispersed like impact pressures, reach ever larger regions of the fluid remote fran the body and became equal to zero; in the fluid there remain hydrodynamic pressures corresponding to the motion of the body after the impact. Neglecting the forces of viscosity and taking into account, furthermore, that the motion of the fluid begins from a state of rest, according to Thomson's theorem, we may consider the motion of an ideal compressible fluid in the process of impact to be potential. We examine the case of impact upon the surface of a ccmpressible fluid of a flat plate of infinite extent or of a body, the immersed part of the surface of which may be called approximately flat. In this report we discuss the first phase of the impact pressure on the surface of a fluid, prior to the appearance of a cavity, since at this stage the hydrodynamic pressures reach their maximum values. Observations, after the fall of the bodies on the surface of the fluid, show that the free surface of the fluid at this stage is almost completely at rest if one does not take into account the small rise in the neighborhood of the boundaries of the impact surface.

  19. Laboratory diagnosis of Ebola virus disease and corresponding biosafety considerations in the China Ebola Treatment Center.

    PubMed

    Huang, Qing; Fu, Wei-Ling; You, Jian-Ping; Mao, Qing

    2016-10-01

    Ebola virus disease (EVD), caused by Ebola virus (EBOV), is a potent acute infectious disease with a high case-fatality rate. Etiological and serological EBOV detection methods, including techniques that involve the detection of the viral genome, virus-specific antigens and anti-virus antibodies, are standard laboratory diagnostic tests that facilitate confirmation or exclusion of EBOV infection. In addition, routine blood tests, liver and kidney function tests, electrolytes and coagulation tests and other diagnostic examinations are important for the clinical diagnosis and treatment of EVD. Because of the viral load in body fluids and secretions from EVD patients, all body fluids are highly contagious. As a result, biosafety control measures during the collection, transport and testing of clinical specimens obtained from individuals scheduled to undergo EBOV infection testing (including suspected, probable and confirmed cases) are crucial. This report has been generated following extensive work experience in the China Ebola Treatment Center (ETC) in Liberia and incorporates important information pertaining to relevant diagnostic standards, clinical significance, operational procedures, safety controls and other issues related to laboratory testing of EVD. Relevant opinions and suggestions are presented in this report to provide contextual awareness associated with the development of standards and/or guidelines related to EVD laboratory testing.

  20. Hydrops fetalis

    MedlinePlus

    ... in skin color (pallor) More severe forms may cause: Breathing problems Bruising or purplish bruise-like spots on the skin Heart failure Severe anemia Severe jaundice Total body swelling Exams and Tests An ultrasound done during pregnancy may show: High levels of amniotic fluid Abnormally ...

  1. Transport of fluid and solutes in the body I. Formulation of a mathematical model.

    PubMed

    Gyenge, C C; Bowen, B D; Reed, R K; Bert, J L

    1999-09-01

    A compartmental model of short-term whole body fluid, protein, and ion distribution and transport is formulated. The model comprises four compartments: a vascular and an interstitial compartment, each with an embedded cellular compartment. The present paper discusses the assumptions on which the model is based and describes the equations that make up the model. Fluid and protein transport parameters from a previously validated model as well as ionic exchange parameters from the literature or from statistical estimation [see companion paper: C. C. Gyenge, B. D. Bowen, R. K. Reed, and J. L. Bert. Am. J. Physiol. 277 (Heart Circ. Physiol. 46): H1228-H1240, 1999] are used in formulating the model. The dynamic model has the ability to simulate 1) transport across the capillary membrane of fluid, proteins, and small ions and their distribution between the vascular and interstitial compartments; 2) the changes in extracellular osmolarity; 3) the distribution and transport of water and ions associated with each of the cellular compartments; 4) the cellular transmembrane potential; and 5) the changes of volume in the four fluid compartments. The validation and testing of the proposed model against available experimental data are presented in the companion paper.

  2. Inorganic particle analysis of dental impression elastomers.

    PubMed

    Carlo, Hugo Lemes; Fonseca, Rodrigo Borges; Soares, Carlos José; Correr, Américo Bortolazzo; Correr-Sobrinho, Lourenço; Sinhoreti, Mário Alexandre Coelho

    2010-01-01

    The aim of this study was to determine quantitatively and qualitatively the inorganic particle fraction of commercially available dental elastomers. The inorganic volumetric fraction of two addition silicones (Reprosil Putty/Fluid and Flexitime Easy Putty/Fluid), three condensation silicones (Clonage Putty/Fluid, Optosil Confort/Xantopren VL and Silon APS Putty/Fluid), one polyether (Impregum Soft Light Body) and one polysulfide (Permlastic Light Body) was accessed by weighing a previously determined mass of each material in water before and after burning samples at 600 ºC, during 3 h. Unsettled material samples were soaked in acetone and chloroform for removal of the organic portion. The remaining filler particles were sputter-coated with gold evaluation of their morphology and size, under scanning electron microscopy (SEM). Flexitime Easy Putty was the material with the highest results for volumetric particle fraction, while Impregum Soft had the lowest values. Silon 2 APS Fluid presented the lowest mean filler size values, while Clonage Putty had the highest values. SEM micrographs of the inorganic particles showed several morphologies - lathe-cut, spherical, spherical-like, sticks, and sticks mixed to lathe-cut powder. The results of this study revealed differences in particle characteristics among the elastometic materials that could lead to different results when testing mechanical properties.

  3. Self-powered implantable electronic-skin for in situ analysis of urea/uric-acid in body fluids and the potential applications in real-time kidney-disease diagnosis.

    PubMed

    Yang, Wenyan; Han, Wuxiao; Gao, Huiling; Zhang, Linlin; Wang, Shuai; Xing, Lili; Zhang, Yan; Xue, Xinyu

    2018-01-25

    As the concentration of different biomarkers in human body fluids are an important parameter of chronic disease, wearable biosensors for in situ analysis of body fluids with high sensitivity, real-time detection, flexibility and biocompatibility have significant potential therapeutic applications. In this paper, a flexible self-powered implantable electronic-skin (e-skin) for in situ body fluids analysis (urea/uric-acid) as a real-time kidney-disease diagnoser has been proposed based on the piezo-enzymatic-reaction coupling process of ZnO nanowire arrays. It can convert the mechanical energy of body movements into a piezoelectric impulse, and the outputting piezoelectric signal contains the urea/uric-acid concentration information in body fluids. This piezoelectric-biosensing process does not need an external electricity supply or battery. The e-skin was implanted under the abdominal skin of a mouse and provided in situ analysis of the kidney-disease parameters. These results provide a new approach for developing a self-powered in situ body fluids-analysis technique for chronic-disease diagnosis.

  4. The Tuskegee Syphilis Experiment: biotechnology and the administrative state.

    PubMed

    Roy, B

    1995-01-01

    The central issue of the Tuskegee Syphilis Experiment was property: property in the body and intellectual property. Once removed from the body, tissue and body fluids were not legally the property of the Tuskegee subjects. Consequently, there was not a direct relationship between a patient and research that used his sera. The Public Health Service (PHS) was free to exercise its property right in Tuskegee sera to develop serologic tests for syphilis with commercial potential. To camouflage the true meaning, the PHS made a distinction between direct clinical studies and indirect studies of tissue and body fluids. This deception caused all reviews to date to limit their examination to documents labeled by the PHS as directly related to the Tuskegee Syphilis Experiment. This excluded other information in the public domain. Despite the absence of a clinical protocol, this subterfuge led each to falsely conclude that the Tuskagee Syphilis Experiment was a clinical study. Based on publications of indirect research using sera and cerebrospinal fluid, this article conceives a very history of the Tuskagee Syphilis Experiment. Syphilis could only cultivate in living beings. As in slavery, the generative ability of the body made the Tuskegee subjects real property and gave untreated syphilis and the sera of the Tuskegee subjects immense commercial value. Published protocols exploited the Tuskegee Syphilis Experiment to invent and commercialize biotechnology for the applied science of syphilis serology.

  5. The Tuskegee Syphilis Experiment: biotechnology and the administrative state.

    PubMed Central

    Roy, B.

    1995-01-01

    The central issue of the Tuskegee Syphilis Experiment was property: property in the body and intellectual property. Once removed from the body, tissue and body fluids were not legally the property of the Tuskegee subjects. Consequently, there was not a direct relationship between a patient and research that used his sera. The Public Health Service (PHS) was free to exercise its property right in Tuskegee sera to develop serologic tests for syphilis with commercial potential. To camouflage the true meaning, the PHS made a distinction between direct clinical studies and indirect studies of tissue and body fluids. This deception caused all reviews to date to limit their examination to documents labeled by the PHS as directly related to the Tuskegee Syphilis Experiment. This excluded other information in the public domain. Despite the absence of a clinical protocol, this subterfuge led each to falsely conclude that the Tuskagee Syphilis Experiment was a clinical study. Based on publications of indirect research using sera and cerebrospinal fluid, this article conceives a very history of the Tuskagee Syphilis Experiment. Syphilis could only cultivate in living beings. As in slavery, the generative ability of the body made the Tuskegee subjects real property and gave untreated syphilis and the sera of the Tuskegee subjects immense commercial value. Published protocols exploited the Tuskegee Syphilis Experiment to invent and commercialize biotechnology for the applied science of syphilis serology. PMID:7869408

  6. Quantification of interstitial fluid on whole body CT: comparison with whole body autopsy.

    PubMed

    Lo Gullo, Roberto; Mishra, Shelly; Lira, Diego A; Padole, Atul; Otrakji, Alexi; Khawaja, Ranish Deedar Ali; Pourjabbar, Sarvenaz; Singh, Sarabjeet; Shepard, Jo-Anne O; Digumarthy, Subba R; Kalra, Mannudeep K; Stone, James R

    2015-12-01

    Interstitial fluid accumulation can occur in pleural, pericardial, and peritoneal spaces, and subcutaneous tissue planes. The purpose of the study was to assess if whole body CT examination in a postmortem setting could help determine the presence and severity of third space fluid accumulation in the body. Our study included 41 human cadavers (mean age 61 years, 25 males and 16 females) who had whole-body postmortem CT prior to autopsy. All bodies were maintained in the morgue in the time interval between death and autopsy. Two radiologists reviewed the whole-body CT examinations independently to grade third space fluid in the pleura, pericardium, peritoneum, and subcutaneous space using a 5-point grading system. Qualitative CT grading for third space fluid was correlated with the amount of fluid found on autopsy and the quantitative CT fluid volume, estimated using a dedicated software program (Volume, Syngo Explorer, Siemens Healthcare). Moderate and severe peripheral edema was seen in 16/41 and 7/41 cadavers respectively. It is not possible to quantify anasarca at autopsy. Correlation between imaging data for third space fluid and the quantity of fluid found during autopsy was 0.83 for pleural effusion, 0.4 for pericardial effusion and 0.9 for ascites. The degree of anasarca was significantly correlated with the severity of ascites (p < 0.0001) but not with pleural or pericardial effusion. There was strong correlation between volumetric estimation and qualitative grading for anasarca (p < 0.0001) and pleural effusion (p < 0.0001). Postmortem CT can help in accurate detection and quantification of third space fluid accumulation. The quantity of ascitic fluid on postmortem CT can predict the extent of anasarca.

  7. A universal constraint-based formulation for freely moving immersed bodies in fluids

    NASA Astrophysics Data System (ADS)

    Patankar, Neelesh A.

    2012-11-01

    Numerical simulation of moving immersed bodies in fluids is now practiced routinely. A variety of variants of these approaches have been published, most of which rely on using a background mesh for the fluid equations and tracking the body using Lagrangian points. In this talk, generalized constraint-based governing equations will be presented that provide a unified framework for various immersed body techniques. The key idea that is common to these methods is to assume that the entire fluid-body domain is a ``fluid'' and then to constrain the body domain to move in accordance with its governing equations. The immersed body can be rigid or deforming. The governing equations are developed so that they are independent of the nature of temporal or spatial discretization schemes. Specific choices of time stepping and spatial discretization then lead to techniques developed in prior literature ranging from freely moving rigid to elastic self-propelling bodies. To simulate Brownian systems, thermal fluctuations can be included in the fluid equations via additional random stress terms. Solving the fluctuating hydrodynamic equations coupled with the immersed body results in the Brownian motion of that body. The constraint-based formulation leads to fractional time stepping algorithms a la Chorin-type schemes that are suitable for fast computations of rigid or self-propelling bodies whose deformation kinematics are known. Support from NSF is gratefully acknowledged.

  8. Maintained total body water content and serum sodium concentrations despite body mass loss in female ultra-runners drinking ad libitum during a 100 km race.

    PubMed

    Knechtle, Beat; Senn, Oliver; Imoberdorf, Reinhard; Joleska, Irena; Wirth, Andrea; Knechtle, Patrizia; Rosemann, Thomas

    2010-01-01

    We investigated in 11 female ultra-runners during a 100 km ultra-run, the association between fluid intake and prevalence of exercise-associated hyponatremia in a cross-sectional study. Athletes drank ad libitum and recorded their fluid intake. They competed at 8.0 (1.0) km/h and finished within 762 (91) min. Fluid intake was 4.1 (1.3) L during the race, equal to 0.3 (0.1) L/h. Body mass decreased by 1.5 kg (p< 0.01); pre race body mass was related to speed in the race (r = -0.78, p< 0.05); and change (Delta) in body mass was not associated with speed in the race. Change in body mass was positively (r = 0.70; p< 0.05), and Delta urinary specific gravity negatively (r = -0.67; p< 0.05), correlated to Delta percent total body water. Changes in body mass were not related to fluid intake during the race. Fluid intake was not correlated to running speed and showed no association with either Delta percent total body water nor Delta [Na] in plasma. Fluid intake showed no relationship with both Delta haematocrit and Delta plasma volume. No exercise-associated hyponatremia occurred. Female ultra- runners consuming fluids ad libitum during the race experienced no fluid overload, and ad libitum drinking protects against exercise-associated hyponatremia. The reported higher incidence of exercise-associated hyponatremia in women is not really a gender effect but due to women being more prone to overdrink.

  9. Bions: A Family of Biomimetic Mineralo-Organic Complexes Derived from Biological Fluids

    PubMed Central

    Martel, Jan; Young, John D.

    2013-01-01

    Mineralo-organic nanoparticles form spontaneously in human body fluids when the concentrations of calcium and phosphate ions exceed saturation. We have shown previously that these mineralo-organic nanoparticles possess biomimetic properties and can reproduce the whole phenomenology of the so-called nanobacteria—mineralized entities initially described as the smallest microorganisms on earth. Here, we examine the possibility that various charged elements and ions may form mineral nanoparticles with similar properties in biological fluids. Remarkably, all the elements tested, including sodium, magnesium, aluminum, calcium, manganese, iron, cobalt, nickel, copper, zinc, strontium, and barium form mineralo-organic particles with bacteria-like morphologies and other complex shapes following precipitation with phosphate in body fluids. Upon formation, these mineralo-organic particles, which we term bions, invariably accumulate carbonate apatite during incubation in biological fluids; yet, the particles also incorporate additional elements and thus reflect the ionic milieu in which they form. Bions initially harbor an amorphous mineral phase that gradually converts to crystals in culture. Our results show that serum produces a dual inhibition-seeding effect on bion formation. Using a comprehensive proteomic analysis, we identify a wide range of proteins that bind to these mineral particles during incubation in medium containing serum. The two main binding proteins identified, albumin and fetuin-A, act as both inhibitors and seeders of bions in culture. Notably, bions possess several biomimetic properties, including the possibility to increase in size and number and to be sub-cultured in fresh culture medium. Based on these results, we propose that bions represent biological, mineralo-organic particles that may form in the body under both physiological and pathological homeostasis conditions. These mineralo-organic particles may be part of a physiological cycle that regulates the function, transport and disposal of elements and minerals in the human body. PMID:24086546

  10. Drug Testing in Oral Fluid

    PubMed Central

    Drummer, Olaf H

    2006-01-01

    Over the last decade there have been considerable developments in the use of oral fluid (saliva) for drug testing. Oral fluid can provide a quick and non-invasive specimen for drug testing. However, its collection may be thwarted by lack of available fluid due to a range of physiological factors, including drug use itself. Food and techniques designed to stimulate production of oral fluid can also affect the concentration of drugs. Current applications are mainly focused on drugs of abuse testing in employees at workplaces where drug use has safety implications, in drivers of vehicles at the roadside and in other situations where drug impairment is suspected. Testing has included alcohol (ethanol) and a range of clinical tests eg antibodies to HIV, therapeutic drugs and steroids. Its main application has been for testing for drugs of abuse such as the amphetamines, cocaine and metabolites, opioids such as morphine, methadone and heroin, and for cannabis. Oral fluid concentrations of basic drugs such as the amphetamines, cocaine and some opioids are similar or higher than those in plasma. Tetrahydrocannabinol (THC), the major species present from cannabis use, displays similar concentrations in oral fluid compared to blood in the elimination phase. However, there is significant local absorption of the drug in the oral cavity which increases the concentrations for a period after use of drug. Depot effects occur for other drugs introduced into the body that allow local absorption, such as smoking of tobacco (nicotine), cocaine, amphetamines, or use of sub-lingual buprenorphine. Screening techniques are usually an adaptation of those used in other specimens, with an emphasis on the parent drug since this is usually the dominant species present in oral fluid. Confirmatory techniques are largely based on mass spectrometry (MS) with an emphasis on Liquid Chromatography-Mass Spectrometry (LC-MS), due to low sample volumes and the low detection limits required. Drug testing outside laboratory environments has become widespread and provides presumptive results within minutes of collection of specimens. This review focuses on the developments, particularly over the last 10 years, and outlines the roles and applications of testing for drugs in oral fluid, describes the difficulties associated with this form of testing and illustrates applications of oral fluid testing for specific drugs. PMID:17268583

  11. 21 CFR 866.5430 - Beta-2-glycoprotein I immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the beta-2-glycoprotein I (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Beta-2-glycoprotein I immunological test system. 866.5430 Section 866.5430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  12. 21 CFR 866.5430 - Beta-2-glycoprotein I immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the beta-2-glycoprotein I (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Beta-2-glycoprotein I immunological test system. 866.5430 Section 866.5430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  13. 21 CFR 866.5440 - Beta-2-glycoprotein III immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... the beta-2-glycoprotein III (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Beta-2-glycoprotein III immunological test system. 866.5440 Section 866.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  14. 21 CFR 866.5430 - Beta-2-glycoprotein I immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the beta-2-glycoprotein I (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Beta-2-glycoprotein I immunological test system. 866.5430 Section 866.5430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  15. 21 CFR 866.5440 - Beta-2-glycoprotein III immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the beta-2-glycoprotein III (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Beta-2-glycoprotein III immunological test system. 866.5440 Section 866.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  16. 21 CFR 866.5440 - Beta-2-glycoprotein III immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... the beta-2-glycoprotein III (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Beta-2-glycoprotein III immunological test system. 866.5440 Section 866.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  17. 21 CFR 866.5430 - Beta-2-glycoprotein I immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... the beta-2-glycoprotein I (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Beta-2-glycoprotein I immunological test system. 866.5430 Section 866.5430 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  18. 21 CFR 866.5440 - Beta-2-glycoprotein III immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... the beta-2-glycoprotein III (a serum protein) in serum and other body fluids. Measurement of beta-2... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Beta-2-glycoprotein III immunological test system. 866.5440 Section 866.5440 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  19. Application of kidney inhibition swab tests to evaluate penicillin-G residues in sow tissues and body fluids following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    Kidney inhibition swab (KIS) tests, recently adapted by the US FSIS for antibiotics on-site screening, were employed to evaluate the depletion of penicillin-G residues from kidney, liver, muscle, serum, and urine of sows after intramuscular (IM) penicillin-G procaine administration. Sows (n=130; 22...

  20. A Randomized, Double Crossover Study to Investigate the Influence of Saline Infusion on Sleep Apnea Severity in Men

    PubMed Central

    Yadollahi, Azadeh; Gabriel, Joseph M.; White, Laura H.; Taranto Montemurro, Luigi; Kasai, Takatoshi; Bradley, T. Douglas

    2014-01-01

    Study Objectives: Obstructive sleep apnea (OSA) is commoner in patients with fluid-retaining states than in those without fluid retention, in men than in women, and worsens with aging. In men, OSA severity is related to the amount of fluid shifting out of the legs overnight, but a cause-effect relationship is not established. Our objective was to test the hypothesis that mimicking fluid overload during sleep would increase severity of OSA more in older (≥ 40 years) than in younger men (< 40 years). Design: Randomized, single-blind, double crossover study. Setting: Research sleep laboratory. Patients or Participants: Seven older and 10 younger men with non-severe or no sleep apnea, matched for body mass index. Interventions: During the control arm, normal saline was infused to keep the vein open. During intervention, subjects received an intravenous bolus of normal saline (22 mL/kg body weight) after sleep onset while they were wearing compression stockings to prevent fluid accumulation in the legs. Measurements and Results: Compared to younger men, infusion of similar amounts of saline in older men caused a greater increase in neck circumference (P < 0.05) and in the AHI (32.2 ± 22.1 vs. 2.2 ± 7.1, P = 0.002). Conclusions: Older men are more susceptible to the adverse effects of intravenous fluid loading on obstructive sleep apnea severity than younger men. This may be due to age-related differences in the amount of fluid accumulating in the neck or upper airway collapsibility in response to intravenous fluid loading. These possibilities remain to be tested in future studies. Citation: Yadollahi A, Gabriel JM, White LH, Taranto Montemurro L, Kasai T, Bradley TD. A randomized, double crossover study to investigate the influence of saline infusion on sleep apnea severity in men. SLEEP 2014;37(10):1699-1705. PMID:25197812

  1. 21 CFR 349.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... of acids or bases from such sources as drugs, body fluids, tears, etc. (d) Demulcent. An agent... membrane surfaces and relieve dryness and irritation. (e) Emollient. An agent, usually a fat or oil, which... present in body tissues and fluids, so that water is drawn from the body tissues and fluids across...

  2. 21 CFR 349.3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... of acids or bases from such sources as drugs, body fluids, tears, etc. (d) Demulcent. An agent... membrane surfaces and relieve dryness and irritation. (e) Emollient. An agent, usually a fat or oil, which... present in body tissues and fluids, so that water is drawn from the body tissues and fluids across...

  3. 21 CFR 349.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... of acids or bases from such sources as drugs, body fluids, tears, etc. (d) Demulcent. An agent... membrane surfaces and relieve dryness and irritation. (e) Emollient. An agent, usually a fat or oil, which... present in body tissues and fluids, so that water is drawn from the body tissues and fluids across...

  4. Partitioning of body fluids in the Lake Nicaragua shark and three marine sharks.

    PubMed

    THORSON, T B

    1962-11-09

    The relative volumes of major body fluids of freshwater and marine sharks are remarkably similar in spite of the differences in external medium and in osmotic pressure of body fluids. The small differences detected are in agreement with differences reported in comparisons of freshwater and marine teleosts: a slightly higher total water content and a smiller ratio of extracellular to intracellular fluids in freshwater forms.

  5. Impact of food and fluid intake on technical and biological measurement error in body composition assessment methods in athletes.

    PubMed

    Kerr, Ava; Slater, Gary J; Byrne, Nuala

    2017-02-01

    Two, three and four compartment (2C, 3C and 4C) models of body composition are popular methods to measure fat mass (FM) and fat-free mass (FFM) in athletes. However, the impact of food and fluid intake on measurement error has not been established. The purpose of this study was to evaluate standardised (overnight fasted, rested and hydrated) v. non-standardised (afternoon and non-fasted) presentation on technical and biological error on surface anthropometry (SA), 2C, 3C and 4C models. In thirty-two athletic males, measures of SA, dual-energy X-ray absorptiometry (DXA), bioelectrical impedance spectroscopy (BIS) and air displacement plethysmography (BOD POD) were taken to establish 2C, 3C and 4C models. Tests were conducted after an overnight fast (duplicate), about 7 h later after ad libitum food and fluid intake, and repeated 24 h later before and after ingestion of a specified meal. Magnitudes of changes in the mean and typical errors of measurement were determined. Mean change scores for non-standardised presentation and post meal tests for FM were substantially large in BIS, SA, 3C and 4C models. For FFM, mean change scores for non-standardised conditions produced large changes for BIS, 3C and 4C models, small for DXA, trivial for BOD POD and SA. Models that included a total body water (TBW) value from BIS (3C and 4C) were more sensitive to TBW changes in non-standardised conditions than 2C models. Biological error is minimised in all models with standardised presentation but DXA and BOD POD are acceptable if acute food and fluid intake remains below 500 g.

  6. Cardiovascular response to lower body negative pressure stimulation before, during, and after space flight

    NASA Technical Reports Server (NTRS)

    Baisch, F.; Beck, L.; Blomqvist, G.; Wolfram, G.; Drescher, J.; Rome, J. L.; Drummer, C.

    2000-01-01

    BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.

  7. Release of Si from Silicon, a Ferrosilicon (FeSi) Alloy and a Synthetic Silicate Mineral in Simulated Biological Media

    PubMed Central

    Herting, Gunilla; Jiang, Tao; Sjöstedt, Carin; Odnevall Wallinder, Inger

    2014-01-01

    Unique quantitative bioaccessibility data has been generated, and the influence of surface/material and test media characteristics on the elemental release process were assessed for silicon containing materials in specific synthetic body fluids at certain time periods at a fixed loading. The metal release test protocol, elaborated by the KTH team, has previously been used for classification, ranking, and screening of different alloys and metals. Time resolved elemental release of Si, Fe and Al from particles, sized less than 50 µm, of two grades of metallurgical silicon (high purity silicon, SiHG, low purity silicon, SiLG), an alloy (ferrosilicon, FeSi) and a mineral (aluminium silicate, AlSi) has been investigated in synthetic body fluids of varying pH, composition and complexation capacity, simple models of for example dermal contact and digestion scenarios. Individual methods for analysis of released Si (as silicic acid, Si(OH)4) in synthetic body fluids using GF-AAS were developed for each fluid including optimisation of solution pH and graphite furnace parameters. The release of Si from the two metallurgical silicon grades was strongly dependent on both pH and media composition with the highest release in pH neutral media. No similar effect was observed for the FeSi alloy or the aluminium silicate mineral. Surface adsorption of phosphate and lactic acid were believed to hinder the release of Si whereas the presence of citric acid enhanced the release as a result of surface complexation. An increased presence of Al and Fe in the material (low purity metalloid, alloy or mineral) resulted in a reduced release of Si in pH neutral media. The release of Si was enhanced for all materials with Al at their outermost surface in acetic media. PMID:25225879

  8. Body fluid volumes in rats with mestranol-induced hypertension

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, W.L. Jr.; Johnson, J.A.; Kurz, K.D.

    Because estrogens have been reported to produce sodium retention, this study investigated the possibility that hypertension in rats resulting from the ingestion of an estrogen used as an oral contraceptive could be due to increases in body fluid volumes. Female rats were given feed containing mestranol for 1, 3, and 6 mo; control rats were given the feed without mestranol. The mestranol-treated rats had higher arterial pressures than the controls only after 6 mo of treatment. Plasma volume, extracellular fluid volume, and total body water were measured in each rat by the distribution volumes of radioiodinated serum albumin, /sup 32/SO/submore » 4/, and tritiated water, respectively. The body fluid volumes, expressed per 100 g of body weight, were not different between the mestranol-treated rats and their controls at any of the three treatment times. Due to differences in body weight and lean body mass between the mestranol-treated and the control rats, these volumes also were expressed per 100 g of lean body mass. Again, no differences were observed between the mestranol-treated rats and the control rats for any of these body fluid compartments at any of the treatment times. These studies, therefore, were unable to provide evidence that increases in body fluid volumes contributed to the elevated arterial pressure in this rat model of oral contraceptive hypertension.« less

  9. Regulation of body fluid volume and electrolyte concentrations in spaceflight.

    PubMed

    Smith, S M; Krauhs, J M; Leach, C S

    1997-01-01

    Despite a number of difficulties in performing experiments during weightlessness, a great deal of information has been obtained concerning the effects of spaceflight on the regulation of body fluid and electrolytes. Many paradoxes and questions remain, however. Although body mass, extracellular fluid volume, and plasma volume are reduced during spaceflight and remain so at landing, the changes in total body water are comparatively small. Serum or plasma sodium and osmolality have generally been unchanged or reduced during the spaceflight, and fluid intake is substantially reduced, especially during the first of flight. The diuresis that was predicted to be caused by weightlessness, has only rarely been observed as an increased urine volume. What has been well established by now, is the occurrence of a relative diuresis, where fluid intake decreases more than urine volume does. Urinary excretion of electrolytes has been variable during spaceflight, but retention of fluid and electrolytes at landing has been consistently observed. The glomerular filtration rate was significantly elevated during the SLS missions, and water and electrolyte loading tests have indicated that renal function is altered during readaptation to Earth's gravity. Endocrine control of fluid volumes and electrolyte concentrations may be altered during weightlessness, but levels of hormones in body fluids do not conform to predictions based on early hypotheses. Antidiuretic hormone is not suppressed, though its level is highly variable and its secretion may be affected by space motion sickness and environmental factors. Plasma renin activity and aldosterone are generally elevated at landing, consistent with sodium retention, but inflight levels have been variable. Salt intake may be an important factor influencing the levels of these hormones. The circadian rhythm of cortisol has undoubtedly contributed to its variability, and little is known yet about the influence of spaceflight on circadian rhythms. Atrial natriuretic peptide does not seem to play an important role in the control of natriuresis during spaceflight. Inflight activity of the sympathetic nervous system, assessed by measuring catecholamines and their metabolites and precursors in body fluids, generally seems to be no greater than on Earth, but this system is usually activated at landing. Collaborative experiments on the Mir and the International Space Station should provide more of the data needed from long-term flights, and perhaps help to resolve some of the discrepancies between U.S. and Russian data. The use of alternative methods that are easier to execute during spaceflight, such as collection of saliva instead of blood and urine, should permit more thorough study of circadian rhythms and rapid hormone changes in weightlessness. More investigations of dietary intake of fluid and electrolytes must be performed to understand regulatory processes. Additional hormones that may participate in these processes, such as other natriuretic hormones, should be determined during and after spaceflight. Alterations in body fluid volume and blood electrolyte concentrations during spaceflight have important consequences for readaptation to the 1-G environment. The current assessment of fluid and electrolyte status during weightlessness and at landing and our still incomplete understanding of the processes of adaptation to weightlessness and readaptation to Earth's gravity have resulted in the development of countermeasures that are only partly successful in reducing the postflight orthostatic intolerance experienced by astronauts and cosmonauts. More complete knowledge of these processes can be expected to produce countermeasures that are even more successful, as well as expand our comprehension of the range of adaptability of human physiologic processes.

  10. Regulation of body fluid volume and electrolyte concentrations in spaceflight

    NASA Technical Reports Server (NTRS)

    Smith, S. M.; Krauhs, J. M.; Leach, C. S.

    1997-01-01

    Despite a number of difficulties in performing experiments during weightlessness, a great deal of information has been obtained concerning the effects of spaceflight on the regulation of body fluid and electrolytes. Many paradoxes and questions remain, however. Although body mass, extracellular fluid volume, and plasma volume are reduced during spaceflight and remain so at landing, the changes in total body water are comparatively small. Serum or plasma sodium and osmolality have generally been unchanged or reduced during the spaceflight, and fluid intake is substantially reduced, especially during the first of flight. The diuresis that was predicted to be caused by weightlessness, has only rarely been observed as an increased urine volume. What has been well established by now, is the occurrence of a relative diuresis, where fluid intake decreases more than urine volume does. Urinary excretion of electrolytes has been variable during spaceflight, but retention of fluid and electrolytes at landing has been consistently observed. The glomerular filtration rate was significantly elevated during the SLS missions, and water and electrolyte loading tests have indicated that renal function is altered during readaptation to Earth's gravity. Endocrine control of fluid volumes and electrolyte concentrations may be altered during weightlessness, but levels of hormones in body fluids do not conform to predictions based on early hypotheses. Antidiuretic hormone is not suppressed, though its level is highly variable and its secretion may be affected by space motion sickness and environmental factors. Plasma renin activity and aldosterone are generally elevated at landing, consistent with sodium retention, but inflight levels have been variable. Salt intake may be an important factor influencing the levels of these hormones. The circadian rhythm of cortisol has undoubtedly contributed to its variability, and little is known yet about the influence of spaceflight on circadian rhythms. Atrial natriuretic peptide does not seem to play an important role in the control of natriuresis during spaceflight. Inflight activity of the sympathetic nervous system, assessed by measuring catecholamines and their metabolites and precursors in body fluids, generally seems to be no greater than on Earth, but this system is usually activated at landing. Collaborative experiments on the Mir and the International Space Station should provide more of the data needed from long-term flights, and perhaps help to resolve some of the discrepancies between U.S. and Russian data. The use of alternative methods that are easier to execute during spaceflight, such as collection of saliva instead of blood and urine, should permit more thorough study of circadian rhythms and rapid hormone changes in weightlessness. More investigations of dietary intake of fluid and electrolytes must be performed to understand regulatory processes. Additional hormones that may participate in these processes, such as other natriuretic hormones, should be determined during and after spaceflight. Alterations in body fluid volume and blood electrolyte concentrations during spaceflight have important consequences for readaptation to the 1-G environment. The current assessment of fluid and electrolyte status during weightlessness and at landing and our still incomplete understanding of the processes of adaptation to weightlessness and readaptation to Earth's gravity have resulted in the development of countermeasures that are only partly successful in reducing the postflight orthostatic intolerance experienced by astronauts and cosmonauts. More complete knowledge of these processes can be expected to produce countermeasures that are even more successful, as well as expand our comprehension of the range of adaptability of human physiologic processes.

  11. Property and privacy paradigms of "marketable spit": an ethical and legal counterpart to blood?

    PubMed

    Vernillo, Anthony Thomas; Wolpe, Paul Root

    2010-01-01

    Major advances in the testing of oral fluid (e.g., saliva) may lead to the diagnosis and treatment of previously undiagnosed conditions and may enable dentists to manage oral disease more effectively. Such use of another body fluid, blood, is already well established. Blood is a complex tissue that has been extensively researched and is now used for a wide variety of diagnostic tests. It is also regarded as a form of property with ethical and legal dimensions. If saliva is to fulfill a similar role, it should perhaps be granted those same protections. This paper advances the concept that saliva should be considered a form of property, possibly within personal biological materials law. The emerging potential for the development of marketable products from oral fluids raises the issue of protecting the research participant's ethical and legal rights. In particular, violation of privacy and genetic discrimination may arise from the testing of salivary DNA. Respect for autonomy requires that the clinician inform a patient or research participant about his or her rights to property and privacy as these may pertain to oral fluid.

  12. Implementation of a study to examine the persistence of Ebola virus in the body fluids of Ebola virus disease survivors in Sierra Leone: Methodology and lessons learned

    PubMed Central

    Marrinan, Jaclyn E.; Sesay, Foday R.; Ervin, Elizabeth; Thorson, Anna E.; Xu, Wenbo; Ströher, Ute; Ongpin, Patricia; Abad, Neetu; Ariyarajah, Archchun; Malik, Tasneem; Liu, Hongtu; Ross, Christine; Durski, Kara N.; Gaillard, Philippe; Morgan, Oliver; Formenty, Pierre; Knust, Barbara; Broutet, Nathalie; Sahr, Foday

    2017-01-01

    Background The 2013–2016 West African Ebola virus disease epidemic was unprecedented in terms of the number of cases and survivors. Prior to this epidemic there was limited data available on the persistence of Ebola virus in survivors’ body fluids and the potential risk of transmission, including sexual transmission. Methodology/Principal findings Given the urgent need to determine the persistence of Ebola virus in survivors’ body fluids, an observational cohort study was designed and implemented during the epidemic response operation in Sierra Leone. This publication describes study implementation methodology and the key lessons learned. Challenges encountered during implementation included unforeseen duration of follow-up, complexity of interpreting and communicating laboratory results to survivors, and the urgency of translating research findings into public health practice. Strong community engagement helped rapidly implement the study during the epidemic. The study was conducted in two phases. The first phase was initiated within five months of initial protocol discussions and assessed persistence of Ebola virus in semen of 100 adult men. The second phase assessed the persistence of virus in multiple body fluids (semen or vaginal fluid, menstrual blood, breast milk, and urine, rectal fluid, sweat, saliva, tears), of 120 men and 120 women. Conclusion/Significance Data from this study informed national and global guidelines in real time and demonstrated the need to implement semen testing programs among Ebola virus disease survivors. The lessons learned and study tools developed accelerated the implementation of such programs in Ebola virus disease affected countries, and also informed studies examining persistence of Zika virus. Research is a vital component of the public health response to an epidemic of a poorly characterized disease. Adequate resources should be rapidly made available to answer critical research questions, in order to better inform response efforts. PMID:28892501

  13. Implementation of a study to examine the persistence of Ebola virus in the body fluids of Ebola virus disease survivors in Sierra Leone: Methodology and lessons learned.

    PubMed

    Deen, Gibrilla Fadlu; McDonald, Suzanna L R; Marrinan, Jaclyn E; Sesay, Foday R; Ervin, Elizabeth; Thorson, Anna E; Xu, Wenbo; Ströher, Ute; Ongpin, Patricia; Abad, Neetu; Ariyarajah, Archchun; Malik, Tasneem; Liu, Hongtu; Ross, Christine; Durski, Kara N; Gaillard, Philippe; Morgan, Oliver; Formenty, Pierre; Knust, Barbara; Broutet, Nathalie; Sahr, Foday

    2017-09-01

    The 2013-2016 West African Ebola virus disease epidemic was unprecedented in terms of the number of cases and survivors. Prior to this epidemic there was limited data available on the persistence of Ebola virus in survivors' body fluids and the potential risk of transmission, including sexual transmission. Given the urgent need to determine the persistence of Ebola virus in survivors' body fluids, an observational cohort study was designed and implemented during the epidemic response operation in Sierra Leone. This publication describes study implementation methodology and the key lessons learned. Challenges encountered during implementation included unforeseen duration of follow-up, complexity of interpreting and communicating laboratory results to survivors, and the urgency of translating research findings into public health practice. Strong community engagement helped rapidly implement the study during the epidemic. The study was conducted in two phases. The first phase was initiated within five months of initial protocol discussions and assessed persistence of Ebola virus in semen of 100 adult men. The second phase assessed the persistence of virus in multiple body fluids (semen or vaginal fluid, menstrual blood, breast milk, and urine, rectal fluid, sweat, saliva, tears), of 120 men and 120 women. Data from this study informed national and global guidelines in real time and demonstrated the need to implement semen testing programs among Ebola virus disease survivors. The lessons learned and study tools developed accelerated the implementation of such programs in Ebola virus disease affected countries, and also informed studies examining persistence of Zika virus. Research is a vital component of the public health response to an epidemic of a poorly characterized disease. Adequate resources should be rapidly made available to answer critical research questions, in order to better inform response efforts.

  14. Forensic interlaboratory evaluation of the ForFLUID kit for vaginal fluids identification.

    PubMed

    Giampaoli, Saverio; Alessandrini, Federica; Berti, Andrea; Ripani, Luigi; Choi, Ajin; Crab, Roselien; De Vittori, Elisabetta; Egyed, Balazs; Haas, Cordula; Lee, Hwan Young; Korabecná, Marie; Noel, Fabrice; Podini, Daniele; Tagliabracci, Adriano; Valentini, Alessio; Romano Spica, Vincenzo

    2014-01-01

    Identification of vaginal fluids is an important step in the process of sexual assaults confirmation. Advances in both microbiology and molecular biology defined technical approaches allowing the discrimination of body fluids. These protocols are based on the identification of specific bacterial communities by microfloraDNA (mfDNA) amplification. A multiplex real time-PCR assay (ForFLUID kit) has been developed for identifying biological fluids and for discrimination among vaginal, oral and fecal samples. In order to test its efficacy and reliability of the assay in the identification of vaginal fluids, an interlaboratory evaluation has been performed on homogeneous vaginal swabs. All the involved laboratories were able to correctly recognize all the vaginal swabs, and no false positives were identified when the assay was applied on non-vaginal samples. The assay represents an useful molecular tool that can be easily adopted by forensic geneticists involved in vaginal fluid identification. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  15. Physiological water model development

    NASA Technical Reports Server (NTRS)

    Doty, Susan

    1993-01-01

    The water of the human body can be categorized as existing in two main compartments: intracellular water and extracellular water. The intracellular water consists of all the water within the cells and constitutes over half of the total body water. Since red blood cells are surrounded by plasma, and all other cells are surrounded by interstitial fluid, the intracellular compartment has been subdivided to represent these two cell types. The extracellular water, which includes all of the fluid outside of the cells, can be further subdivided into compartments which represent the interstitial fluid, circulating blood plasma, lymph, and transcellular water. The interstitial fluid surrounds cells outside of the vascular system whereas plasma is contained within the blood vessels. Avascular tissues such as dense connective tissue and cartilage contain interstitial water which slowly equilibrates with tracers used to determine extracellular fluid volume. For this reason, additional compartments are sometimes used to represent these avascular tissues. The average size of each compartment, in terms of percent body weight, has been determined for adult males and females. These compartments and the forces which cause flow between them are presented. The kidneys, a main compartment, receive about 25 percent of the cardiac output and filters out a fluid similar to plasma. The composition of this filtered fluid changes as it flows through the kidney tubules since compounds are continually being secreted and reabsorbed. Through this mechanism, the kidneys eliminate wastes while conserving body water, electrolytes, and metabolites. Since sodium accounts for over 90 percent of the cations in the extracellular fluid, and the number of cations is balanced by the number of anions, considering the renal handling sodium and water only should sufficiently describe the relationship between the plasma compartment and kidneys. A kidney function model is presented which has been adapted from a previous model of normal renal function in man. To test the validity of the proposed kidney model, results predicted by the model will be compared to actual data involving injected or ingested fluids and subsequent urine flow rates. Comparison of the model simulation to actual data following the ingestion of 1 liter of water is shown. The model simulation is also shown with actual data following the intravenous infusion of hypertonic saline.

  16. Neural Control Mechanisms and Body Fluid Homeostasis

    NASA Technical Reports Server (NTRS)

    Johnson, Alan Kim

    1998-01-01

    The goal of the proposed research was to study the nature of afferent signals to the brain that reflect the status of body fluid balance and to investigate the central neural mechanisms that process this information for the activation of response systems which restore body fluid homeostasis. That is, in the face of loss of fluids from intracellular or extracellular fluid compartments, animals seek and ingest water and ionic solutions (particularly Na(+) solutions) to restore the intracellular and extracellular spaces. Over recent years, our laboratory has generated a substantial body of information indicating that: (1) a fall in systemic arterial pressure facilitates the ingestion of rehydrating solutions and (2) that the actions of brain amine systems (e.g., norepinephrine; serotonin) are critical for precise correction of fluid losses. Because both acute and chronic dehydration are associated with physiological stresses, such as exercise and sustained exposure to microgravity, the present research will aid in achieving a better understanding of how vital information is handled by the nervous system for maintenance of the body's fluid matrix which is critical for health and well-being.

  17. On the Comparison of the Long Penetration Mode (LPM) Supersonic Counterflowing Jet to the Supersonic Screech Jet

    NASA Technical Reports Server (NTRS)

    Farr, Rebecca A.; Chang, Chau-Lyan.; Jones, Jess H.; Dougherty, N. Sam

    2015-01-01

    The authors provide a brief overview of the classic tonal screech noise problem created by underexpanded supersonic jets, briefly describing the fluid dynamic-acoustics feedback mechanism that has been long established as the basis for this well-known aeroacoustics problem. This is followed by a description of the Long Penetration Mode (LPM) supersonic underexpanded counterflowing jet phenomenon which has been demonstrated in several wind tunnel tests and modeled in several computational fluid dynamics (CFD) simulations. The authors provide evidence from test and CFD analysis of LPM that indicates that acoustics feedback and fluid interaction seen in LPM are analogous to the aeroacoustics interactions seen in screech jets. Finally, the authors propose applying certain methodologies to LPM which have been developed and successfully demonstrated in the study of screech jets and mechanically induced excitation in fluid oscillators for decades. The authors conclude that the large body of work done on jet screech, other aeroacoustic phenomena, and fluid oscillators can have direct application to the study and applications of LPM counterflowing supersonic cold flow jets.

  18. Accurate fluid force measurement based on control surface integration

    NASA Astrophysics Data System (ADS)

    Lentink, David

    2018-01-01

    Nonintrusive 3D fluid force measurements are still challenging to conduct accurately for freely moving animals, vehicles, and deforming objects. Two techniques, 3D particle image velocimetry (PIV) and a new technique, the aerodynamic force platform (AFP), address this. Both rely on the control volume integral for momentum; whereas PIV requires numerical integration of flow fields, the AFP performs the integration mechanically based on rigid walls that form the control surface. The accuracy of both PIV and AFP measurements based on the control surface integration is thought to hinge on determining the unsteady body force associated with the acceleration of the volume of displaced fluid. Here, I introduce a set of non-dimensional error ratios to show which fluid and body parameters make the error negligible. The unsteady body force is insignificant in all conditions where the average density of the body is much greater than the density of the fluid, e.g., in gas. Whenever a strongly deforming body experiences significant buoyancy and acceleration, the error is significant. Remarkably, this error can be entirely corrected for with an exact factor provided that the body has a sufficiently homogenous density or acceleration distribution, which is common in liquids. The correction factor for omitting the unsteady body force, {{{ {ρ f}} {1 - {ρ f} ( {{ρ b}+{ρ f}} )}.{( {{{{ρ }}b}+{ρ f}} )}}} , depends only on the fluid, {ρ f}, and body, {{ρ }}b, density. Whereas these straightforward solutions work even at the liquid-gas interface in a significant number of cases, they do not work for generalized bodies undergoing buoyancy in combination with appreciable body density inhomogeneity, volume change (PIV), or volume rate-of-change (PIV and AFP). In these less common cases, the 3D body shape needs to be measured and resolved in time and space to estimate the unsteady body force. The analysis shows that accounting for the unsteady body force is straightforward to non-intrusively and accurately determine fluid force in most applications.

  19. [Correction of the human body hydration in different periods of space flight].

    PubMed

    Noskov, V B

    2003-01-01

    Hydration level of the human body at the end of space flight is not same as at its beginning. This was the reason for development and testing of opposite in action methods for hydration improvement: at the onset of microgravity a dehydration therapy is applied and, on the contrary, in the final period of space flight methods for retaining body fluids are of preference. Consumption of a diuretic and a water-salt supplement by orbiting crews reached the required effect suggesting applicability of the pharmaceutical correction as a measure against dehydration.

  20. Experimental and computational flow-field results for an all-body hypersonic aircraft

    NASA Technical Reports Server (NTRS)

    Cleary, Joseph W.

    1989-01-01

    A comprehensive test program is defined which is being implemented in the NASA/Ames 3.5 foot Hypersonic Wind Tunnel for obtaining data on a generic all-body hypersonic vehicle for computational fluid dynamics (CFD) code validation. Computational methods (approximate inviscid methods and an upwind parabolized Navier-Stokes code) currently being applied to the all-body model are outlined. Experimental and computational results on surface pressure distributions and Pitot-pressure surveys for the basic sharp-nose model (without control surfaces) at a free-stream Mach number of 7 are presented.

  1. Evaluation of penicillin G residues by kidney inhibition swab tests in sow body fluids and tissues following intramuscular injection

    USDA-ARS?s Scientific Manuscript database

    In 2011, the USDA-Food Safety and Inspection Service (FSIS) changed the method used for screening swine tissues for antimicrobial residues to the Kidney Inhibition Swab (KIS(TM)) from the Fast Antimicrobial Screen Test. A high dose of penicillin G procaine relative to a label dose is commonly used ...

  2. Plasma volume and blood viscosity during 4 h sitting in a dry environment: effect of prehydration.

    PubMed

    Doi, Tatsuya; Sakurai, Masao; Hamada, Koichiro; Matsumoto, Keitaro; Yanagisawa, Kae; Kikuchi, Noriaki; Morimoto, Taketoshi; Greenleaf, John E

    2004-06-01

    Deep vein thrombosis and pulmonary thromboembolism are potential problems for travelers, including those who fly. We hypothesized that prehydration with an electrolyte-glucose beverage (EGB) would be better than water for maintaining body fluid balance and preventing increased blood viscosity in immobilized men. There were 12 healthy men (24-38 yr) who participated in crossover trials of prehydration using EGB and H2O as well as a control condition (Con) with no prehydration. Fluid intake was set at 6 ml x kg(-1) body weight (mean 418 ml). For each trial, subjects sat for 4 h at a dry-bulb temperature of 23.0-23.5 degrees C and a relative humidity of 18-36%. Plasma volume (PV) and whole blood viscosity (Bvis) were determined every hour; routine laboratory hematological tests, urine volume, and body weight were recorded at 2 h and 4 h. For Con, subjects lost approximately 110 ml h(-1); at 2 h, PV had decreased significantly by 3.4%, and Bvis had increased significantly by 9.3%, with no further change at 4 h. For prehydration, retention of the consumed fluid at 2 h was significantly higher for EGB (57%) than for H2O (38%), while both drinks prevented significant change in PV and Bvis. There were no significant differences between trials in coagulation variables, but Bvis measured at higher shear rates for EGB were significantly attenuated compared with Con. EGB and water prevented the increase of blood viscosity that occurred without prehydration. EGB was better than water for maintaining body fluid balance and preventing hypovolemia.

  3. Vascular Uptake of Six Rehydration Drinks at Rest and Exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Geelen, G.; Jackson, C. G. R.; Saumet, J.-L.; Juhos, L. T.; Keil, L. C.; Fegan-Meyer, D.; Dearborn, A.; Hinghofer-Szalkay, H.; Whittam, J. H.

    1996-01-01

    A report presents data on the effectiveness of each of six rehydration fluids in restoring total body water and plasma volume in human subjects during rest and exercise. One of the six fluids was water sweetened with aspartame: the others were water containing various amounts of sodium chloride and/or sodium citrate, plus various amounts of aspartame and/or other carbohydrates. In one experiment, five men who had previously dehydrated themselves for 24 hours drank one of the rehydration fluids, then sat for 70 minutes. Pretest plasma volumes were measured and changes in plasma volumes were calculated. This procedure was repeated at weekly intervals until all six rehydration fluids had been tested. Another similar experiment involved four men who exercised on a cycle ergometer for 70 minutes in the supine position after drinking the fluids.

  4. Laboratory investigation of a fluid-dynamic actuator designed for CubeSats

    NASA Astrophysics Data System (ADS)

    Noack, Daniel; Brieß, Klaus

    2014-03-01

    In general, the attitude control systems (ACS) for precise spacecraft operations rely on reaction wheel technology for angular momentum exchange. In this paper, an alternative ACS concept using fluid rings for this task is presented. This novel actuator—based on Lorentz body force—uses a direct-current conduction pump to accelerate liquid metal within a circular channel structure. As working fluid for the fluid-dynamic actuator (FDA) serves the eutectic alloy Galinstan. Along with a microcontroller that runs the FDA, a MEMS gyroscope is implemented on the device for closed loop operation. Several models of FDAs for small satellites were tested successfully for various attitude control maneuvers on an air bearing platform. Thus advantageous performance has been achieved in terms of torque and power consumption in comparison to similarly dimensioned reaction wheels. Further considerable advantages are wear-free operations and higher reliability as well as expected passive damping properties. A next generation FDA prototype for nano-satellites is currently in development for in-orbit testing.

  5. Existence of time-periodic weak solutions to the stochastic Navier-Stokes equations around a moving body

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Feng, E-mail: chenfengmath@163.com, E-mail: hanyc@jlu.edu.cn; Han, Yuecai, E-mail: chenfengmath@163.com, E-mail: hanyc@jlu.edu.cn

    2013-12-15

    The existence of time-periodic stochastic motions of an incompressible fluid is obtained. Here the fluid is subject to a time-periodic body force and an additional time-periodic stochastic force that is produced by a rigid body moves periodically stochastically with the same period in the fluid.

  6. Scalded skin syndrome

    MedlinePlus

    ... infection. IV fluids are also given to prevent dehydration. Much of the body's fluid is lost through open skin. Moist compresses ... result include: Abnormal level of fluids in the body causing ... or electrolyte imbalance Poor temperature control (in young ...

  7. NASA Environmentally Responsible Aviation Hybrid Wing Body Flow-Through Nacelle Wind Tunnel CFD

    NASA Technical Reports Server (NTRS)

    Schuh, Michael J.; Garcia, Jospeh A.; Carter, Melissa B.; Deere, Karen A.; Stremel, Paul M.; Tompkins, Daniel M.

    2016-01-01

    Wind tunnel tests of a 5.75% scale model of the Boeing Hybrid Wing Body (HWB) configuration were conducted in the NASA Langley Research Center (LaRC) 14'x22' and NASA Ames Research Center (ARC) 40'x80' low speed wind tunnels as part of the NASA Environmentally Responsible Aviation (ERA) Project. Computational fluid dynamics (CFD) simulations of the flow-through nacelle (FTN) configuration of this model were performed before and after the testing. This paper presents a summary of the experimental and CFD results for the model in the cruise and landing configurations.

  8. NASA Environmentally Responsible Aviation Hybrid Wing Body Flow-Through Nacelle Wind Tunnel CFD

    NASA Technical Reports Server (NTRS)

    Schuh, Michael J.; Garcia, Joseph A.; Carter, Melissa B.; Deere, Karen A.; Tompkins, Daniel M.; Stremel, Paul M.

    2016-01-01

    Wind tunnel tests of a 5.75 scale model of the Boeing Hybrid Wing Body (HWB) configuration were conducted in the NASA Langley Research Center (LaRC) 14x22 and NASA Ames Research Center (ARC) 40x80 low speed wind tunnels as part of the NASA Environmentally Responsible Aviation (ERA) Project. Computational fluid dynamics (CFD) simulations of the flow-through nacelle (FTN) configuration of this model were performed before and after the testing. This paper presents a summary of the experimental and CFD results for the model in the cruise and landing configurations.

  9. Insights on the criteria of selection of vegetable and mineral dielectric fluids used in power transformers on the basis of their biodegradability and toxicity assessments.

    PubMed

    Módenes, Aparecido Nivaldo; Sanderson, Karina; Trigueros, Daniela Estelita Goes; Schuelter, Adilson Ricken; Espinoza-Quiñones, Fernando Rodolfo; Neves, Camila Vargas; Zanão Junior, Luiz Antônio; Kroumov, Alexander Dimitrov

    2018-05-01

    Leakage of transformer dielectric fluids is a concern because it may pose a risk of environmental contamination. In this study, the deleterious effects of vegetable and mineral dielectric fluids in water bodies were investigated using biodegradability and acute toxicity tests with Danio rerio and Artemia salina. Regarding biodegradability, all four tested vegetable oils (soy, canola, sunflower and crambe) were considered as easily biodegradable, presenting degradation rates significantly higher than the Lubrax-type mineral fluid. Acute toxicity tests were performed in two separate experiments without solution renewal. In the first experiment, the organisms were exposed in direct contact to different concentrations of vegetable (soy) and mineral (Lubrax) oils. Total soy-type vegetable oil has a higher toxic effect than Lubrax-type mineral oil. In the second experiment, the organisms were exposed to increasing percentages of the water-soluble fraction (WSF) of both types of tested oils. The LC 50 values for the water-soluble fraction of the Lubrax-type mineral oil were about 5 and 8% for the Danio rerio and Artemia salina bioindicators, respectively, whereas the vegetable oil did not present toxic effect, regardless of its WSF. These results have shown that a strict selection of dielectric fluids and monitoring the leakage from power transformers is a serious duty of environmental protection agencies. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Forensic discrimination of vaginal epithelia by DNA methylation analysis through pyrosequencing.

    PubMed

    Antunes, Joana; Silva, Deborah S B S; Balamurugan, Kuppareddi; Duncan, George; Alho, Clarice S; McCord, Bruce

    2016-10-01

    The accurate identification of body fluids from crime scenes can aid in the discrimination between criminal and innocent intent. This research aimed to determine if the levels of DNA methylation in the locus PFN3A could be used to discriminate vaginal epithelia from other body fluids. In this work we bisulfite-modified and amplified DNA samples from blood, saliva, semen, and vaginal epithelia using primers for PFN3A. Through pyrosequencing we were able to show that vaginal epithelia present distinct methylation levels when compared to other body fluids. Mixtures of different body fluids present methylation values that correlate with single-source body fluid samples and the primers for PFN3A are specific for primates. This report successfully demonstrated that the analysis of methylation in the PFN3A locus can be used for vaginal epithelia discrimination in forensic samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Non-Invasive Electromagnetic Skin Patch Sensor to Measure Intracranial Fluid–Volume Shifts

    PubMed Central

    Griffith, Jacob; Cluff, Kim; Eckerman, Brandon; Aldrich, Jessica; Becker, Ryan; Moore-Jansen, Peer; Patterson, Jeremy

    2018-01-01

    Elevated intracranial fluid volume can drive intracranial pressure increases, which can potentially result in numerous neurological complications or death. This study’s focus was to develop a passive skin patch sensor for the head that would non-invasively measure cranial fluid volume shifts. The sensor consists of a single baseline component configured into a rectangular planar spiral with a self-resonant frequency response when impinged upon by external radio frequency sweeps. Fluid volume changes (10 mL increments) were detected through cranial bone using the sensor on a dry human skull model. Preliminary human tests utilized two sensors to determine feasibility of detecting fluid volume shifts in the complex environment of the human body. The correlation between fluid volume changes and shifts in the first resonance frequency using the dry human skull was classified as a second order polynomial with R2 = 0.97. During preliminary and secondary human tests, a ≈24 MHz and an average of ≈45.07 MHz shifts in the principal resonant frequency were measured respectively, corresponding to the induced cephalad bio-fluid shifts. This electromagnetic resonant sensor may provide a non-invasive method to monitor shifts in fluid volume and assist with medical scenarios including stroke, cerebral hemorrhage, concussion, or monitoring intracranial pressure. PMID:29596338

  12. Survey of 800+ data sets from human tissue and body fluid reveals xenomiRs are likely artifacts

    PubMed Central

    Kang, Wenjing; Bang-Berthelsen, Claus Heiner; Holm, Anja; Houben, Anna J.S.; Müller, Anne Holt; Thymann, Thomas; Pociot, Flemming; Estivill, Xavier; Friedländer, Marc R.

    2017-01-01

    miRNAs are small 22-nucleotide RNAs that can post-transcriptionally regulate gene expression. It has been proposed that dietary plant miRNAs can enter the human bloodstream and regulate host transcripts; however, these findings have been widely disputed. We here conduct the first comprehensive meta-study in the field, surveying the presence and abundances of cross-species miRNAs (xenomiRs) in 824 sequencing data sets from various human tissues and body fluids. We find that xenomiRs are commonly present in tissues (17%) and body fluids (69%); however, the abundances are low, comprising 0.001% of host human miRNA counts. Further, we do not detect a significant enrichment of xenomiRs in sequencing data originating from tissues and body fluids that are exposed to dietary intake (such as liver). Likewise, there is no significant depletion of xenomiRs in tissues and body fluids that are relatively separated from the main bloodstream (such as brain and cerebro-spinal fluids). Interestingly, the majority (81%) of body fluid xenomiRs stem from rodents, which are a rare human dietary contribution but common laboratory animals. Body fluid samples from the same studies tend to group together when clustered by xenomiR compositions, suggesting technical batch effects. Last, we performed carefully designed and controlled animal feeding studies, in which we detected no transfer of plant miRNAs into rat blood, or bovine milk sequences into piglet blood. In summary, our comprehensive computational and experimental results indicate that xenomiRs originate from technical artifacts rather than dietary intake. PMID:28062594

  13. Tensiometer and method of determining soil moisture potential in below-grade earthen soil

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    1997-01-01

    A portable tensiometer to in situ determine below-grade soil moisture potential of earthen soil includes, a) a body having opposing first and second ends and being adapted for complete insertion into earthen soil below grade; b) a porous material provided at the first body end, the porous material at least in part defining a fluid chamber within the body at the first body end, the fluid chamber being fluidically sealed within the body but for the porous material; c) a degassed liquid received within the fluid chamber; d) a pressure transducer mounted in fluid communication with the fluid chamber; e) the body, pressure transducer and degassed liquid having a combined mass; f) a flexible suspension line connected to the body adjacent the second body end, the flexible line being of sufficient strength to gravitationally freely self suspend the combined mass; and c) the combined mass being sufficient to effectively impart hydraulic communication between below-grade earthen soil contacted by the porous material under the weight of the combined mass. Tensiometers configured to engage the sidewalls of an earthen opening are also disclosed. Methods of taking tensiometric measurements are also disclosed.

  14. Tensiometer and method of determining soil moisture potential in below-grade earthen soil

    DOEpatents

    Hubbell, J.M.; Sisson, J.B.

    1997-07-08

    A portable tensiometer to in-situ determine below-grade soil moisture potential of earthen soil includes, (a) a body having opposing first and second ends and being adapted for complete insertion into earthen soil below grade; (b) a porous material provided at the first body end, the porous material at least in part defining a fluid chamber within the body at the first body end, the fluid chamber being fluidically sealed within the body but for the porous material; (c) a degassed liquid received within the fluid chamber; (d) a pressure transducer mounted in fluid communication with the fluid chamber; (e) the body, pressure transducer and degassed liquid having a combined mass; (f) a flexible suspension line connected to the body adjacent the second body end, the flexible line being of sufficient strength to gravitationally freely self suspend the combined mass; and (g) the combined mass being sufficient to effectively impart hydraulic communication between below-grade earthen soil contacted by the porous material under the weight of the combined mass. Tensiometers configured to engage the sidewalls of an earthen opening are also disclosed. Methods of taking tensiometric measurements are also disclosed. 12 figs.

  15. Two-body perturbation theory versus first order perturbation theory: A comparison based on the square-well fluid.

    PubMed

    Mercier Franco, Luís Fernando; Castier, Marcelo; Economou, Ioannis G

    2017-12-07

    We show that the Zwanzig first-order perturbation theory can be obtained directly from a truncated Taylor series expansion of a two-body perturbation theory and that such truncation provides a more accurate prediction of thermodynamic properties than the full two-body perturbation theory. This unexpected result is explained by the quality of the resulting approximation for the fluid radial distribution function. We prove that the first-order and the two-body perturbation theories are based on different approximations for the fluid radial distribution function. To illustrate the calculations, the square-well fluid is adopted. We develop an analytical expression for the two-body perturbed Helmholtz free energy for the square-well fluid. The equation of state obtained using such an expression is compared to the equation of state obtained from the first-order approximation. The vapor-liquid coexistence curve and the supercritical compressibility factor of a square-well fluid are calculated using both equations of state and compared to Monte Carlo simulation data. Finally, we show that the approximation for the fluid radial distribution function given by the first-order perturbation theory provides closer values to the ones calculated via Monte Carlo simulations. This explains why such theory gives a better description of the fluid thermodynamic behavior.

  16. Water and electrolytes. [in human bodies

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Harrison, M. H.

    1986-01-01

    It has been found that the performance of the strongest and fittest people will deteriorate rapidly with dehydration. The present paper is concerned with the anatomy of the fluid spaces in the body, taking into account also the fluid shifts and losses during exercise and their effects on performance. Total body water is arbitrarily divided into that contained within cells (cellular) and that located outside the cells (extracellular). The anatomy of body fluid compartments is considered along with the effects of exercise on body water, fluid shifts with exercise, the consequences of sweating, dehydration and exercise, heat acclimatization and endurance training, the adverse effects of dehydration, thirst and drinking during exercise, stimuli for drinking, and water, electrolyte, and carbohydrate replacement during exercise. It is found that the deterioration of physical exercise performance due to dehydration begins when body weight decreases by about 1 percent.

  17. Understanding Fluid Shifts in the Brain: Choroidal Regulation Involved in the Cerebral Fluid Response to Altered Gravity

    NASA Technical Reports Server (NTRS)

    Gabrion, Jaqueline; Vasques, Marilyn; Aquilina, Rudy (Technical Monitor)

    2002-01-01

    Fluid balance and regulation of body fluid production are critical aspects of life and survival on Earth. In space, without gravity exerting its usual downward pulling effect, the fluids of the human body shift in an unnatural, headward direction. After awhile, humans and other mammalian species adapt to the microgravity environment which leads to changes in the regulation and distribution of these body fluids. Previous spaceflight experiments have indicated that production of fluid in the brain and spinal cord, cerebrospinal fluid (CSF), might be reduced in rats exposed to microgravity. In this experiment conducted by Dr. Jacqueline Gabrion (University of Pierre and Marie Curie, France), proteins important for CSF production, and several molecules that regulate water and mineral transport, will be investigated in rats flown on the Shuttle. Dr. Gabrion and her team will determine the amounts of these proteins and molecules present in the brain in order to evaluate whether any changes have taken place during the rats' adaptation to microgravity. The levels of different aquaporins (proteins that act as a channel for water transport in and out of cells) will also be investigated in other areas of the brain and body to better understand the regulatory responses affecting these important water channel proteins. In addition to producing essential and basic information about fluid production in the brain and body, this experiment will reveal fundamental information about the mechanisms involved in cerebral adaptation and fluid balance during spaceflight.

  18. Spike-Nosed Bodies and Forward Injected Jets in Supersonic Flow

    NASA Technical Reports Server (NTRS)

    Gilinsky, M.; Washington, C.; Blankson, I. M.; Shvets, A. I.

    2002-01-01

    The paper contains new numerical simulation and experimental test results of blunt body drag reduction using thin spikes mounted in front of a body and one- or two-phase jets injected against a supersonic flow. Numerical simulations utilizing the NASA CFL3D code were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory (FM&AL) and experimental tests were conducted using the facilities of the IM/MSU Aeromechanics and Gas Dynamics Laboratory. Previous results were presented at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference. Those results were based on some experimental and numerical simulation tests for supersonic flow around spike-nosed or shell-nosed bodies, and numerical simulations were conducted only for a single spike-nosed or shell-nosed body at zero attack angle, alpha=0. In this paper, experimental test results of gas, liquid and solid particle jet injection against a supersonic flow are presented. In addition, numerical simulation results for supersonic flow around a multiple spike-nosed body with non-zero attack angles and with a gas and solid particle forward jet injection are included. Aerodynamic coefficients: drag, C(sub D), lift, C(sub L), and longitudinal momentum, M(sub z), obtained by numerical simulation and experimental tests are compared and show good agreement.

  19. Spike-Nosed Bodies and Forward Injected Jets in Supersonic Flow

    NASA Technical Reports Server (NTRS)

    Gilinsky, M.; Washington, C.; Blankson, I. M.; Shvets, A. I.

    2002-01-01

    The paper contains new numerical simulation and experimental test results of blunt body drag reduction using thin spikes mounted in front of a body and one- or two-phase jets injected against a supersonic flow. Numerical simulations utilizing the NASA CFL3D code were conducted at the Hampton University Fluid Mechanics and Acoustics Laboratory (FM&AL) and experimental tests were conducted using the facilities of the IM/MSU Aeromechanics and Gas Dynamics Laboratory. Previous results were presented at the 37th AIAA/ASME/SAE/ASEE Joint Propulsion Conference. Those results were based on some experimental and numerical simulation tests for supersonic flow around spike-nosed or shell-nosed bodies, and numerical simulations were conducted only for a single spike-nosed or shell-nosed body at zero attack angle, alpha = 0 degrees. In this paper, experimental test results of gas, liquid and solid particle jet injection against a supersonic flow are presented. In addition, numerical simulation results for supersonic flow around a multiple spike-nosed body with non-zero attack angles and with a gas and solid particle forward jet injection are included. Aerodynamic coefficients: drag, C (sub D), lift, C(sub L), and longitudinal momentum, M(sub z), obtained by numerical simulation and experimental tests are compared and show good agreement.

  20. Flow force and torque on submerged bodies in lattice-Boltzmann methods via momentum exchange.

    PubMed

    Giovacchini, Juan P; Ortiz, Omar E

    2015-12-01

    We review the momentum exchange method to compute the flow force and torque on a submerged body in lattice-Boltzmann methods by presenting an alternative derivation. Our derivation does not depend on a particular implementation of the boundary conditions at the body surface, and it relies on general principles. After the introduction of the momentum exchange method in lattice-Boltzmann methods, some formulations were introduced to compute the fluid force on static and moving bodies. These formulations were introduced in a rather intuitive, ad hoc way. In our derivation, we recover the proposals most frequently used, in some cases with minor corrections, gaining some insight into the two most used formulations. At the end, we present some numerical tests to compare different approaches on a well-known benchmark test that support the correctness of the formulas derived.

  1. An Application of CFD to Guide Forced Boundary-Layer Transition for Low-Speed Tests of a Hybrid Wing-Body Configuration

    NASA Technical Reports Server (NTRS)

    Luckring, James M.; Deere, Karen A.; Childs, Robert E.; Stremel, Paul M.; Long, Kurtis R.

    2016-01-01

    A hybrid transition trip-dot sizing and placement test technique was developed in support of recent experimental research on a hybrid wing-body configuration under study for the NASA Environmentally Responsible Aviation project. The approach combines traditional methods with Computational Fluid Dynamics. The application had three-dimensional boundary layers that were simulated with either fully turbulent or transitional flow models using established Reynolds-Averaged Navier-Stokes methods. Trip strip effectiveness was verified experimentally using infrared thermography during a low-speed wind tunnel test. Although the work was performed on one specific configuration, the process was based on fundamental flow physics and could be applicable to other configurations.

  2. Noninvasive oxygen partial pressure measurement of human body fluids in vivo using magnetic resonance imaging.

    PubMed

    Zaharchuk, Greg; Busse, Reed F; Rosenthal, Guy; Manley, Geoffery T; Glenn, Orit A; Dillon, William P

    2006-08-01

    The oxygen partial pressure (pO2) of human body fluids reflects the oxygenation status of surrounding tissues. All existing fluid pO2 measurements are invasive, requiring either microelectrode/optode placement or fluid removal. The purpose of this study is to develop a noninvasive magnetic resonance imaging method to measure the pO2 of human body fluids. We developed an imaging paradigm that exploits the paramagnetism of molecular oxygen to create quantitative images of fluid oxygenation. A single-shot fast spin echo pulse sequence was modified to minimize artifacts from motion, fluid flow, and partial volume. Longitudinal relaxation rate (R1 = 1/T1) was measured with a time-efficient nonequilibrium saturation recovery method and correlated with pO2 measured in phantoms. pO2 images of human and fetal cerebrospinal fluid, bladder urine, and vitreous humor are presented and quantitative oxygenation levels are compared with prior literature estimates, where available. Significant pO2 increases are shown in cerebrospinal fluid and vitreous following 100% oxygen inhalation. Potential errors due to temperature, fluid flow, and partial volume are discussed. Noninvasive measurements of human body fluid pO2 in vivo are presented, which yield reasonable values based on prior literature estimates. This rapid imaging-based measurement of fluid oxygenation may provide insight into normal physiology as well as changes due to disease or during treatment.

  3. Feet swelling in a multistage ultraendurance triathlete: a case study

    PubMed Central

    Knechtle, Beat; Zingg, Matthias Alexander; Knechtle, Patrizia; Rosemann, Thomas; Rüst, Christoph Alexander

    2015-01-01

    Recent studies investigating ultraendurance athletes showed an association between excessive fluid intake and swelling of the lower limbs such as the feet. To date, this association has been investigated in single-stage ultraendurance races, but not in multistage ultraendurance races. In this case study, we investigated a potential association between fluid intake and feet swelling in a multistage ultraendurance race such as a Deca Iron ultratriathlon with ten Ironman triathlons within 10 consecutive days. A 49-year-old well-experienced ultratriathlete competed in autumn 2013 in the Deca Iron ultratriathlon held in Lonata del Garda, Italy, and finished the race as winner within 129:33 hours:minutes. Changes in body mass (including body fat and lean body mass), foot volume, total body water, and laboratory measurements were assessed. Food and fluid intake during rest and competing were recorded, and energy and fluid turnovers were estimated. During the ten stages, the volume of the feet increased, percentage body fat decreased, creatinine and urea levels increased, hematocrit and hemoglobin values decreased, and plasma [Na+] remained unchanged. The increase in foot volume was significantly and positively related to fluid intake during the stages. The poststage volume of the foot was related to poststage total body water, poststage creatinine, and poststage urea. This case report shows that the volume of the foot increased during the ten stages, and the increase in volume was significantly and positively related to fluid intake during the stages. Furthermore, the poststage volume of the foot was related to poststage total body water, poststage creatinine, and poststage urea. The continuous feet swelling during the race was most probably due to a combination of a high fluid intake and a progressive decline in renal function (ie, continuous increase in creatinine and urea), leading to body fluid retention (ie, increase in total body water). PMID:26508884

  4. Study on the persistence of Zika virus (ZIKV) in body fluids of patients with ZIKV infection in Brazil.

    PubMed

    Calvet, Guilherme Amaral; Kara, Edna Oliveira; Giozza, Silvana Pereira; Bôtto-Menezes, Camila Helena Aguiar; Gaillard, Philippe; de Oliveira Franca, Rafael Freitas; de Lacerda, Marcus Vinicius Guimarães; da Costa Castilho, Marcia; Brasil, Patrícia; de Sequeira, Patrícia Carvalho; de Mello, Maeve Brito; Bermudez, Ximena Pamela Diaz; Modjarrad, Kayvon; Meurant, Robyn; Landoulsi, Sihem; Benzaken, Adele Schwartz; de Filippis, Ana Maria Bispo; Broutet, Nathalie Jeanne Nicole

    2018-01-22

    Zika virus (ZIKV) has been identified in several body fluids of infected individuals. In most cases, it remained detected in blood from few days to 1 week after the onset of symptoms, and can persist longer in urine and in semen. ZIKV infection can have dramatic consequences such as microcephaly and Guillain-Barré syndrome. ZIKV sexual transmission has been documented. A better understanding of ZIKV presence and persistence across biologic compartments is needed to devise rational measures to prevent its transmission. This observational cohort study will recruit non-pregnant participants aged 18 years and above with confirmed ZIKV infection [positive reverse transcriptase-polymerase chain reaction (RT-PCR) test in blood and/or urine]: symptomatic men and women in ZIKV infection acute phase, and their symptomatic or asymptomatic household/sexual infected contacts. Specimens of blood, urine, semen, vaginal secretion/menstrual blood, rectal swab, oral fluids, tears, sweat, urine and breast milk (if applicable) will be collected at pre-established intervals and tested for ZIKV RNA presence by RT-PCR, other co-infection (dengue, Chikungunya, HIV, hepatitis B and C, syphilis), antibody response (including immunoglobulins M and G), plaque reduction neutralization test (if simultaneously positive for ZIKV and dengue), and ZIKV culture and RNA sequencing. Data on socio-demographic characteristics and comorbidities will be collected in parallel. Participants will be followed up for 12 months. This prolonged longitudinal follow-up of ZIKV infected persons with regular biologic testing and data collection will offer a unique opportunity to investigate the presence and persistence of ZIKV in various biologic compartments, their clinical and immunological correlates as well as the possibility of ZIKV reactivation/reinfection over time. This valuable information will substantially contribute to the body of knowledge on ZIKV infection and serve as a base for the development of more effective recommendation on the prevention of ZIKV transmission. NCT03106714 . Registration Date: April, 7, 2017.

  5. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological... immunoglobulin G (resulting from breakdown of immunoglobulin G antibodies) in urine, serum, and other body fluids. Measurement of immunoglobulin G Fc fragments aids in the diagnosis of plasma cell antibody-forming...

  6. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological... immunoglobulin G (resulting from breakdown of immunoglobulin G antibodies) in urine, serum, and other body fluids. Measurement of immunoglobulin G Fc fragments aids in the diagnosis of plasma cell antibody-forming...

  7. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological... immunoglobulin G (resulting from breakdown of immunoglobulin G antibodies) in urine, serum, and other body fluids. Measurement of immunoglobulin G Fc fragments aids in the diagnosis of plasma cell antibody-forming...

  8. 21 CFR 866.5530 - Immunoglobulin G (Fc fragment specific) immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunological... immunoglobulin G (resulting from breakdown of immunoglobulin G antibodies) in urine, serum, and other body fluids. Measurement of immunoglobulin G Fc fragments aids in the diagnosis of plasma cell antibody-forming...

  9. Evaluation of the Seismic Characterision of Select Engineered Nanoparticles in Saturated Glass Beads

    EPA Science Inventory

    A laboratory testing apparatus was developed for the study of seismic body wave propagation through nanoparticles dispersed in pore fluid that is essentially saturating glass beads. First, the responses of water-saturated glass bead specimens were studied to establish baseline si...

  10. Simultaneous Multiple-Location Separation Control

    NASA Technical Reports Server (NTRS)

    Greenblatt, David (Inventor)

    2009-01-01

    A method of controlling a shear layer for a fluid dynamic body introduces first periodic disturbances into the fluid medium at a first flow separation location. Simultaneously, second periodic disturbances are introduced into the fluid medium at a second flow separation location. A phase difference between the first and second periodic disturbances is adjusted to control flow separation of the shear layer as the fluid medium moves over the fluid dynamic body.

  11. Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

    PubMed

    Baker, Lindsay B

    2017-03-01

    Athletes lose water and electrolytes as a consequence of thermoregulatory sweating during exercise and it is well known that the rate and composition of sweat loss can vary considerably within and among individuals. Many scientists and practitioners conduct sweat tests to determine sweat water and electrolyte losses of athletes during practice and competition. The information gleaned from sweat testing is often used to guide personalized fluid and electrolyte replacement recommendations for athletes; however, unstandardized methodological practices and challenging field conditions can produce inconsistent/inaccurate results. The primary objective of this paper is to provide a review of the literature regarding the effect of laboratory and field sweat-testing methodological variations on sweating rate (SR) and sweat composition (primarily sodium concentration [Na + ]). The simplest and most accurate method to assess whole-body SR is via changes in body mass during exercise; however, potential confounding factors to consider are non-sweat sources of mass change and trapped sweat in clothing. In addition, variability in sweat [Na + ] can result from differences in the type of collection system used (whole body or localized), the timing/duration of sweat collection, skin cleaning procedure, sample storage/handling, and analytical technique. Another aim of this paper is to briefly review factors that may impact intra/interindividual variability in SR and sweat [Na + ] during exercise, including exercise intensity, environmental conditions, heat acclimation, aerobic capacity, body size/composition, wearing of protective equipment, sex, maturation, aging, diet, and/or hydration status. In summary, sweat testing can be a useful tool to estimate athletes' SR and sweat Na + loss to help guide fluid/electrolyte replacement strategies, provided that data are collected, analyzed, and interpreted appropriately.

  12. Transport of fluid and solutes in the body II. Model validation and implications.

    PubMed

    Gyenge, C C; Bowen, B D; Reed, R K; Bert, J L

    1999-09-01

    A mathematical model of short-term whole body fluid, protein, and ion distribution and transport developed earlier [see companion paper: C. C. Gyenge, B. D. Bowen, R. K. Reed, and J. L. Bert. Am. J. Physiol. 277 (Heart Circ. Physiol. 46): H1215-H1227, 1999] is validated using experimental data available in the literature. The model was tested against data measured for the following three types of experimental infusions: 1) hyperosmolar saline solutions with an osmolarity in the range of 2,000-2,400 mosmol/l, 2) saline solutions with an osmolarity of approximately 270 mosmol/l and composition comparable with Ringer solution, and 3) an isosmotic NaCl solution with an osmolarity of approximately 300 mosmol/l. Good agreement between the model predictions and the experimental data was obtained with respect to the trends and magnitudes of fluid shifts between the intra- and extracellular compartments, extracellular ion and protein contents, and hematocrit values. The model is also able to yield information about inaccessible or difficult-to-measure system variables such as intracellular ion contents, cellular volumes, and fluid fluxes across the vascular capillary membrane, data that can be used to help interpret the behavior of the system.

  13. Fluid imbalance

    MedlinePlus

    ... up in the body. This is called fluid overload (volume overload). This can lead to edema (excess fluid in ... Water imbalance; Fluid imbalance - dehydration; Fluid buildup; Fluid overload; Volume overload; Loss of fluids; Edema - fluid imbalance; ...

  14. Interactions between internal forces, body stiffness, and fluid environment in a neuromechanical model of lamprey swimming.

    PubMed

    Tytell, Eric D; Hsu, Chia-Yu; Williams, Thelma L; Cohen, Avis H; Fauci, Lisa J

    2010-11-16

    Animal movements result from a complex balance of many different forces. Muscles produce force to move the body; the body has inertial, elastic, and damping properties that may aid or oppose the muscle force; and the environment produces reaction forces back on the body. The actual motion is an emergent property of these interactions. To examine the roles of body stiffness, muscle activation, and fluid environment for swimming animals, a computational model of a lamprey was developed. The model uses an immersed boundary framework that fully couples the Navier-Stokes equations of fluid dynamics with an actuated, elastic body model. This is the first model at a Reynolds number appropriate for a swimming fish that captures the complete fluid-structure interaction, in which the body deforms according to both internal muscular forces and external fluid forces. Results indicate that identical muscle activation patterns can produce different kinematics depending on body stiffness, and the optimal value of stiffness for maximum acceleration is different from that for maximum steady swimming speed. Additionally, negative muscle work, observed in many fishes, emerges at higher tail beat frequencies without sensory input and may contribute to energy efficiency. Swimming fishes that can tune their body stiffness by appropriately timed muscle contractions may therefore be able to optimize the passive dynamics of their bodies to maximize peak acceleration or swimming speed.

  15. Mechanisms underlying rhythmic locomotion: body–fluid interaction in undulatory swimming

    PubMed Central

    Chen, J.; Friesen, W. O.; Iwasaki, T.

    2011-01-01

    Swimming of fish and other animals results from interactions of rhythmic body movements with the surrounding fluid. This paper develops a model for the body–fluid interaction in undulatory swimming of leeches, where the body is represented by a chain of rigid links and the hydrodynamic force model is based on resistive and reactive force theories. The drag and added-mass coefficients for the fluid force model were determined from experimental data of kinematic variables during intact swimming, measured through video recording and image processing. Parameter optimizations to minimize errors in simulated model behaviors revealed that the resistive force is dominant, and a simple static function of relative velocity captures the essence of hydrodynamic forces acting on the body. The model thus developed, together with the experimental kinematic data, allows us to investigate temporal and spatial (along the body) distributions of muscle actuation, body curvature, hydrodynamic thrust and drag, muscle power supply and energy dissipation into the fluid. We have found that: (1) thrust is generated continuously along the body with increasing magnitude toward the tail, (2) drag is nearly constant along the body, (3) muscle actuation waves travel two or three times faster than the body curvature waves and (4) energy for swimming is supplied primarily by the mid-body muscles, transmitted through the body in the form of elastic energy, and dissipated into the water near the tail. PMID:21270304

  16. Specialized physiological studies in support of manned space flight

    NASA Technical Reports Server (NTRS)

    Luft, U. C.

    1976-01-01

    Subjects were tested for tolerance to lower body negative pressure (LBNP) before and after acute dehydration by working intermittenly for two hours without fluid replacement. On the second day there-after the LBNP tests were repeated before and after acute dehydration. The LBNP test consisted of 5 min long consective stages at -20, -30, -40, -50 and -60 Torr. Tests were terminated when syncope was imminent or the full sequence was completed. Tolerance was expressed in terms of cumulative stress in Torr x min. Measurements of body mass, density, fat fraction and total body water (TBW) were made before and after acclimation. Blood volume and its constituents were determined before and after each of the four LBNP tests. During LBNP, heart rate, blood pressure, and changes in calf and forearm volume were recorded every minute. Results showed: acute dehydration caused a significant loss in average LBNP tolerance on all subjects. Acclimation to heat did not significantly affect LBNP tolerance in hydrated subjects but significantly improved it on dehydrated subjects.

  17. Survey of 800+ data sets from human tissue and body fluid reveals xenomiRs are likely artifacts.

    PubMed

    Kang, Wenjing; Bang-Berthelsen, Claus Heiner; Holm, Anja; Houben, Anna J S; Müller, Anne Holt; Thymann, Thomas; Pociot, Flemming; Estivill, Xavier; Friedländer, Marc R

    2017-04-01

    miRNAs are small 22-nucleotide RNAs that can post-transcriptionally regulate gene expression. It has been proposed that dietary plant miRNAs can enter the human bloodstream and regulate host transcripts; however, these findings have been widely disputed. We here conduct the first comprehensive meta-study in the field, surveying the presence and abundances of cross-species miRNAs (xenomiRs) in 824 sequencing data sets from various human tissues and body fluids. We find that xenomiRs are commonly present in tissues (17%) and body fluids (69%); however, the abundances are low, comprising 0.001% of host human miRNA counts. Further, we do not detect a significant enrichment of xenomiRs in sequencing data originating from tissues and body fluids that are exposed to dietary intake (such as liver). Likewise, there is no significant depletion of xenomiRs in tissues and body fluids that are relatively separated from the main bloodstream (such as brain and cerebro-spinal fluids). Interestingly, the majority (81%) of body fluid xenomiRs stem from rodents, which are a rare human dietary contribution but common laboratory animals. Body fluid samples from the same studies tend to group together when clustered by xenomiR compositions, suggesting technical batch effects. Last, we performed carefully designed and controlled animal feeding studies, in which we detected no transfer of plant miRNAs into rat blood, or bovine milk sequences into piglet blood. In summary, our comprehensive computational and experimental results indicate that xenomiRs originate from technical artifacts rather than dietary intake. © 2017 Kang et al.; Published by Cold Spring Harbor Laboratory Press for the RNA Society.

  18. No Change in 24-Hour Hydration Status Following a Moderate Increase in Fluid Consumption.

    PubMed

    Tucker, Matthew A; Adams, J D; Brown, Lemuel A; Ridings, Christian B; Burchfield, Jenna M; Robinson, Forrest B; McDermott, Jamie L; Schreiber, Brett A; Moyen, Nicole E; Washington, Tyrone A; Bermudez, Andrea C; Bennett, Meredith P; Buyckx, Maxime E; Ganio, Matthew S

    2016-01-01

    To investigate changes in 24-hour hydration status when increasing fluid intake. Thirty-five healthy males (age 23.8 ± 4.7 years; mass 74.0 ± 9.4 kg) were divided into 4 treatment groups for 2 weeks of testing. Volumes of 24-hour fluid ingestion (including water from food) for weeks 1 and 2 was 35 and 40 ml/kg body mass, respectively. Each treatment group was given the same proportion of beverages in each week of testing: water only (n = 10), water + caloric cola (n = 7), water + noncaloric cola (n = 10), or water + caloric cola + noncaloric cola + orange juice (n = 8). Serum osmolality (Sosm), total body water (TBW) via bioelectrical impedance, 24-hour urine osmolality (Uosm), and volume (Uvol) were analyzed at the end of each 24-hour intervention. Independent of treatment, total beverage consumption increased 22% from week 1 to 2 (1685 ± 320 to 2054 ± 363 ml; p < 0.001). Independent of beverage assignment, the increase in fluid consumption between weeks 1 and 2 did not change TBW (43.4 ± 5.2 vs 43.0 ± 4.8 kg), Sosm (292 ± 5 vs 292 ± 5 mOsm/kg), 24-hour Uosm (600 ± 224 vs 571 ± 212 mOsm/kg), or 24-hour Uvol (1569 ± 607 vs 1580 ± 554 ml; all p > 0.05). Regardless of fluid volume or beverage type consumed, measures of 24-hour hydration status did not differ, suggesting that standard measures of hydration status are not sensitive enough to detect a 22% increase in beverage consumption.

  19. On the Comparison of the Long Penetration Mode (LPM) Supersonic Counterflowing Jet to the Supersonic Screech Jet

    NASA Technical Reports Server (NTRS)

    Farr, Rebecca A.; Chang, Chau-Lyan; Jones, Jess H.; Dougherty, N. Sam

    2015-01-01

    Classic tonal screech noise created by under-expanded supersonic jets; Long Penetration Mode (LPM) supersonic phenomenon -Under-expanded counter-flowing jet in supersonic free stream -Demonstrated in several wind tunnel tests -Modeled in several computational fluid dynamics (CFD) simulations; Discussion of LPM acoustics feedback and fluid interactions -Analogous to the aero-acoustics interactions seen in screech jets; Lessons Learned: Applying certain methodologies to LPM -Developed and successfully demonstrated in the study of screech jets -Discussion of mechanically induced excitation in fluid oscillators in general; Conclusions -Large body of work done on jet screech, other aero-acoustic phenomenacan have direct application to the study and applications of LPM cold flow jets

  20. Osmosis, osmometry, and osmoregulation

    PubMed Central

    Lord, R

    1999-01-01

    The maintenance of adequate body fluid volume and the correct distribution of this fluid between the body compartments is a critical part of homeostasis. The process of osmosis plays an important role in movement of fluid within the body and the use of osmometry is an important part of the management of many patients. In addition to the application of osmometry to the measurement of body fluids, most commonly plasma and urine, osmotic action plays a part in some therapeutic actions of drugs and its strength needs to be quantified in fluids administered to patients. Unfortunately confusion often exists in the various terms that are used in the field of osmometry. This review aims to explain the different terms used, the laboratory methodology involved in osmometry, and the clinical application and interpretation of the results obtained.


Keywords: homeostasis; osmolality; osmolarity; colligative properties PMID:10448464

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, S.; Daiwile, A.; Devi, S. S.

    Metallic glasses are a potential and compatible implant candidate for biomedical applications. In the present investigation, a comparative study between novel Zr 55Co 30Ti 15 and Cu 60Zr 20Ti 20 metallic glasses is carried out to evaluate in vitro biocompatibility using simulated body fluids. The bio-corrosion behavior of Zr- and Cu-based metallic glasses in different types of artificial body fluids such as artificial saliva solution, phosphate-buffered saline solution, artificial blood plasma solution, and Hank’s balanced saline solution is evaluated using potentiodynamic polarization studies at a constant body temperature of 310.15 K (37 °C). Surface morphology of samples after bio-corrosion experimentsmore » was observed by scanning electron microscopy. In vitro cytotoxicity test on glassy alloys were performed using human osteosarcoma cell line as per 10993-5 guidelines from International Organization for Standardization. As a result, the comparative study between Zr- and Cu-based glassy alloys provides vital information about the effect of elemental composition on biocompatibility of metallic glasses.« less

  2. 21 CFR 866.5715 - Plasminogen immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Section 866.5715 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... substance from which plasmin, a blood-clotting factor, is formed) in serum, other body fluids, and tissues. Measurement of plasminogen levels may aid in the diagnosis of fibrinolytic (blood-clotting) disorders. (b...

  3. 21 CFR 866.5715 - Plasminogen immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Section 866.5715 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... substance from which plasmin, a blood-clotting factor, is formed) in serum, other body fluids, and tissues. Measurement of plasminogen levels may aid in the diagnosis of fibrinolytic (blood-clotting) disorders. (b...

  4. 21 CFR 866.5715 - Plasminogen immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Section 866.5715 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... substance from which plasmin, a blood-clotting factor, is formed) in serum, other body fluids, and tissues. Measurement of plasminogen levels may aid in the diagnosis of fibrinolytic (blood-clotting) disorders. (b...

  5. 21 CFR 866.5715 - Plasminogen immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Section 866.5715 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... substance from which plasmin, a blood-clotting factor, is formed) in serum, other body fluids, and tissues. Measurement of plasminogen levels may aid in the diagnosis of fibrinolytic (blood-clotting) disorders. (b...

  6. 49 CFR 219.207 - Fatality.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... tissue specimens must be obtained from the remains of the employee for toxicological testing. To ensure... body fluid or tissue specimens. The railroad must also seek the assistance of the custodian of the... the duty officer at the National Response Center (NRC) at (800) 424-8801 or (800) 424-8802 by...

  7. 49 CFR 219.207 - Fatality.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... tissue specimens must be obtained from the remains of the employee for toxicological testing. To ensure... body fluid or tissue specimens. The railroad must also seek the assistance of the custodian of the... the duty officer at the National Response Center (NRC) at (800) 424-8801 or (800) 424-8802 by...

  8. Occupational Exposure of Shiraz Dental Students to Patients’ Blood and Body Fluid

    PubMed Central

    Shaghaghian, Soheila; Golkari, Ali; Pardis, Soheil; Rezayi, Ali

    2015-01-01

    Statement of the Problem Exposure to patients’ blood and body fluids would prone the dental students to the risk of blood borne infections. Several studies have shown a high prevalence of these exposures in dental settings particularly in developing countries. However, few studies have evaluated the epidemiology of these exposures in dental students in Iran. Purpose To assess the epidemiology of occupational exposures among dental students and consequently designing the appropriate interventions in order to prevent these exposures. Materials and Method In this cross-sectional study performed during March to June 2011, all 191 Shiraz clinical dental students were asked to complete a self-administered questionnaire. This questionnaire included demographic information and experience of sharp injuries and mucocutaneous contaminations. Chi square and t-test were employed to evaluate the risk factors of exposure. Results 80%of the participants were exposed to the patients’ blood or body fluids during their clinical course. No association was found between the exposure and demographic factors. Injection needle and recapping were the most common causes of these injuries. The most common sites that were injured and caused mucocutaneous contamination were finger and face, respectively. The most frequent activity causing contamination was using high-speed rotary instruments. Only 6.4% of the exposures had been reported to the related authorities and the remains were underreported. Conclusion Blood and body fluid exposure in dental setting is common and a lot of them are not reported. To reduce the hazards of these exposures, infection control authorities should design interventions especially for mentioned high-risk conditions. They should change dental students’ behavior especially regarding not recapping injection needles and using eyewear. Dental schools seem to need a management center and a standard protocol for following up the exposures. PMID:26331151

  9. Detection and follow-up of torque teno midi virus ("small anelloviruses") in nasopharyngeal aspirates and three other human body fluids in children.

    PubMed

    Burián, Zsófia; Szabó, Hajnalka; Székely, Gyöngyi; Gyurkovits, Kálmán; Pankovics, Péter; Farkas, Tibor; Reuter, Gábor

    2011-09-01

    Torque teno midi virus/small anellovirus (TTMDV/SAV) is a member of the family Anelloviridae. It has a single-stranded, circular, negative-sense DNA genome. Its pathogenic role in human disease remains to be confirmed. In this study, viral shedding, molecular epidemiology and genetic diversity of TTMDV/SAV were studied in human body fluids. Nasopharyngeal aspirates collected from children with acute respiratory disease were tested by PCR/nested PCR for TTMDV/SAV in two seasons (2005/2006, 2006/2007). Two years later, additional urine, stool, and serum samples and nasopharyngeal aspirates were collected from eight symptomless children for follow-up investigation. Forty-three (46.7%) of the 92 nasopharyngeal aspirates collected contained TTMDV/SAV. High genetic diversity was observed; however, identical sequences were also detected in two patients. The mean age of the infected children was 3 years (1 months-8 years), and 58% of them were female. Co-infection with RSV was detected in 23% of the samples. In a follow-up study, nasopharyngeal aspirates and serum of six (75%), stool samples of four (50%) and urine samples of two (25%) of the eight children were anellovirus-positive. None of the anellovirus sequences were identical in the two collection periods, but identical sequences were detected in different body fluids collected at the same time from the same child. TTMDV/SAVs shedding was detected in four human body fluids. As a consequence, it is possible that generalized infection and fecal/uro-oral transmission of TTMDV/SAV occur. TTMDV/SAVs are frequently present in nasopharyngeal aspirates, although the variants may only be transient agents. Further research is needed to investigate the pathogenesis and pathogenic role of TTMDV/SAV.

  10. National Training Course. Emergency Medical Technician. Paramedic. Instructor's Lesson Plans. Module III. Shock and Fluid Therapy.

    ERIC Educational Resources Information Center

    National Highway Traffic Safety Administration (DOT), Washington, DC.

    This instructor's lesson plan guide on shock and fluid therapy is one of fifteen modules designed for use in the training of emergency medical technicians (paramedics). Six units of study are presented: (1) body fluids, electrolytes and their effect on the body, and the general principles of fluid and acid base balances; (2) characteristics of…

  11. A simple model of fluid flow and electrolyte balance in the body

    NASA Technical Reports Server (NTRS)

    White, R. J.; Neal, L.

    1973-01-01

    The model is basically a three-compartment model, the three compartments being the plasma, interstitial fluid and cellular fluid. Sodium, potassium, chloride and urea are the only major solutes considered explicitly. The control of body water and electrolyte distribution is affected via drinking and hormone levels. Basically, the model follows the effect of various oral input water loads on solute and water distribution throughout the body.

  12. Development of mRNA-based body fluid identification using reverse transcription loop-mediated isothermal amplification.

    PubMed

    Satoh, Tetsuya; Kouroki, Seiya; Ogawa, Keita; Tanaka, Yorika; Matsumura, Kazutoshi; Iwase, Susumu

    2018-04-25

    Identifying body fluids from forensic samples can provide valuable evidence for criminal investigations. Messenger RNA (mRNA)-based body fluid identification was recently developed, and highly sensitive parallel identification using reverse transcription polymerase chain reaction (RT-PCR) has been described. In this study, we developed reverse transcription loop-mediated isothermal amplification (RT-LAMP) as a simple, rapid assay for identifying three common forensic body fluids, namely blood, semen, and saliva, and evaluated its specificity and sensitivity. Hemoglobin beta (HBB), transglutaminase 4 (TGM4), and statherin (STATH) were selected as marker genes for blood, semen, and saliva, respectively. RT-LAMP could be performed in a single step including both reverse transcription and DNA amplification under an isothermal condition within 60 min, and detection could be conveniently performed via visual fluorescence. Marker-specific amplification was performed in each assay, and no cross-reaction was observed among five representative forensically relevant body fluids. The detection limits of the assays were 0.3 nL, 30 nL, and 0.3 μL for blood, semen, and saliva, respectively, and their sensitivities were comparable with those of RT-PCR. Furthermore, RT-LAMP assays were applicable to forensic casework samples. It is considered that RT-LAMP is useful for body fluid identification.

  13. Treating Vomiting

    MedlinePlus

    ... those descibed below. Estimated Oral Fluid and Electrolyte Requirements by Body Weight Body Weight (in pounds) Minimum Daily Fluid Requirements (in ounces)* Electrolyte Solution Requirements for Mild Diarrhea ( ...

  14. Investigating the isolation and amplification of microRNAs for forensic body fluid identification.

    PubMed

    Glynn, Claire L; O Leary, Kelsie R

    2018-04-30

    The discovery of forensic DNA typing evolved molecular biology far beyond what could have been expected in terms of its forensic application, and now there exists other developments in molecular biology which are ready for application to forensic challenges. One such challenge is the identification of the body fluid source of stains recovered from evidence items and crime scenes. Currently there are significant efforts in the research field to develop novel methods for the molecular identification of body fluids, with microRNAs (miRNAs) revealing great potential. MiRNAs have been shown to have high tissue specificity and are less susceptible to degradation as a result of their small size, which infers great advantages to their potential role for identifying forensically relevant body fluids. This study investigated the isolation and amplification of miRNAs from forensically relevant body fluids. Venous blood, menstrual blood, semen, saliva, and vaginal material samples were extracted using; miRNeasy® mini kit (Qiagen), mirVana™ miRNA isolation kit (Ambion), and a modified mirVana™ method, and the quality/quantity of isolated miRNA was determined. miRNAs previously identified to show specificity for particular forensically relevant body fluids were examined. Real Time-Quantitative PCR (RT-qPCR) was performed targeting 5 miRNAs of interest, miR-451, miR-412, miR-891a, miR-205 and miR-124a. This study identified the miRNeasy® mini kit as the optimal method of the three methods investigated for the extraction of miRNAs from body fluids and further validates a selection of miRNAs previously suggested as potential biomarkers. This research highlights the potential of miRNAs as novel markers for the identification of forensically relevant body fluids. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. Efficiency of International Classification of Diseases, Ninth Revision, Billing Code Searches to Identify Emergency Department Visits for Blood or Body Fluid Exposures through a Statewide Multicenter Database

    PubMed Central

    Rosen, Lisa M.; Liu, Tao; Merchant, Roland C.

    2016-01-01

    BACKGROUND Blood and body fluid exposures are frequently evaluated in emergency departments (EDs). However, efficient and effective methods for estimating their incidence are not yet established. OBJECTIVE Evaluate the efficiency and accuracy of estimating statewide ED visits for blood or body fluid exposures using International Classification of Diseases, Ninth Revision (ICD-9), code searches. DESIGN Secondary analysis of a database of ED visits for blood or body fluid exposure. SETTING EDs of 11 civilian hospitals throughout Rhode Island from January 1, 1995, through June 30, 2001. PATIENTS Patients presenting to the ED for possible blood or body fluid exposure were included, as determined by prespecified ICD-9 codes. METHODS Positive predictive values (PPVs) were estimated to determine the ability of 10 ICD-9 codes to distinguish ED visits for blood or body fluid exposure from ED visits that were not for blood or body fluid exposure. Recursive partitioning was used to identify an optimal subset of ICD-9 codes for this purpose. Random-effects logistic regression modeling was used to examine variations in ICD-9 coding practices and styles across hospitals. Cluster analysis was used to assess whether the choice of ICD-9 codes was similar across hospitals. RESULTS The PPV for the original 10 ICD-9 codes was 74.4% (95% confidence interval [CI], 73.2%–75.7%), whereas the recursive partitioning analysis identified a subset of 5 ICD-9 codes with a PPV of 89.9% (95% CI, 88.9%–90.8%) and a misclassification rate of 10.1%. The ability, efficiency, and use of the ICD-9 codes to distinguish types of ED visits varied across hospitals. CONCLUSIONS Although an accurate subset of ICD-9 codes could be identified, variations across hospitals related to hospital coding style, efficiency, and accuracy greatly affected estimates of the number of ED visits for blood or body fluid exposure. PMID:22561713

  16. Evaluating Oral Fluid as a Screening Tool for Lead Poisoning.

    PubMed

    Gardner, Sher Lynn; Geller, Robert J; Hannigan, Robyn; Sun, Yu; Mangla, Anil

    2016-11-01

    Screening for lead poisoning is necessary in young children, but obtaining the needed blood sample is unpleasant and sometimes very difficult. Use of an alternative screening method that is less unpleasant and less difficult would likely help to increase the percent of children receiving screening. To evaluate the correlation of oral fluid and blood lead in a clinical setting, and to ascertain the acceptability and feasibility of obtaining oral fluid from a young child in the clinical setting. Oral fluid samples were collected from a convenience sample of 431 children aged 6 months to 5 years already due to receive a blood lead test in a primary care clinic. Blood lead results obtained at the same time were available for 407 children. The results of the two tests were compared with the blood lead test considered to be the "gold standard". Data analysis used Pearson correlations, scatter plots, linear regression, ANOVA and Bland-Altman analysis. 431 patients had oral fluid samples available for analysis, and 407 patients had blood samples available. Patients who had both blood concentrations <5 µg/dL and oral fluid values below the screening cutoff value were 223, while eight had both blood concentrations ≥ 5 µg/dL and oral fluid values above the screening threshold. Elevated oral fluid but blood lead values less than the value recommended for further intervention occurred in 176; no patients had elevated blood lead values with below-intervention oral fluid values. The negative predictive value of an oral fluid lead below the screening cutoff value was 100%. The use of oral fluid to screen for elevated body burdens of lead instead of the usual blood lead sample is feasible with a negative predictive value of 100%, while eliminating the need for blood for lead screening in more than half of these children. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  17. Behavioral responses and fluid regulation in male rats after combined dietary sodium deficiency and water deprivation.

    PubMed

    Lucia, Kimberly J; Curtis, Kathleen S

    2018-02-01

    Most investigators use a single treatment such as water deprivation or dietary sodium deficiency to evaluate thirst or sodium appetite, which underlie behavioral responses to body fluid challenges. The goal of the present experiments was to assess the effects of combined treatments in driving behaviors. Therefore, we evaluated the effect of combined overnight water deprivation and dietary sodium deficiency on water intake and salt intake by adult male rats in 2-bottle (0.5M NaCl and water) tests. Overnight water deprivation alone increased water intake, and 10days of dietary sodium deficiency increased 0.5M NaCl intake, with a secondary increase in water intake. During combined water deprivation and dietary sodium deficiency, water intake was enhanced and 0.5M NaCl was reduced, but not eliminated, suggesting that physiologically relevant behavioral responses persist. Nonetheless, the pattern of fluid intake was altered by the combined treatments. We also assessed the effect of these behaviors on induced deficits in body sodium and fluid volume during combined treatments and found that, regardless of treatment, fluid ingestion partially repleted the induced deficits. Finally, we examined urine volume and sodium excretion during dietary sodium deficiency with or without overnight water deprivation and found that, whether or not rats were water deprived, and regardless of water consumption, sodium excretion was minimal. Thus, the combination of water deprivation and dietary sodium deficiency appears to arouse drives that stimulate compensatory behavioral responses. These behaviors, in conjunction with physiological adaptations to the treatments, underlie body sodium and volume repletion in the face of combined water deprivation and dietary sodium deficiency. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. [LE cells in synovial fluid: prevalence and diagnostic usefulness in rheumatic diseases].

    PubMed

    Puszczewicz, Mariusz; Białkowska-Puszczewicz, Grazyna

    2010-01-01

    This study was undertaken to determine the prevalence of LE cells in synovial fluid and their importance for the diagnosis of rheumatic disease. Synovial fluid was obtained from 631 patients: 31 with systemic lupus erythematosus (SLE), 337 with rheumatoid arthritis (RA), 4 with Still's disease, 9 with systemic scleroderma (SS), 27 with the overlap syndrome (RA/SLE), 132 with ankylosing spondylitis (AS), 57 with Reiter's syndrome, and 34 with psoriatic arthritis (PA). The fluid was centrifuged, precipitate smears were done and were May-Grünwald-Giemsa stained for cytologic assessment. The supernatant was collected for antinuclear antibody (ANA) testing. Physicochemical and serologic properties of the synovial fluid were routinely determined. All synovial fluids demonstrated signs of inflammation. The presence of LE cells was ascertained in five patients with SLE and nine patients with the overlap syndrome. In these cases, LE cells were accompanied by ANA. In addition, hematoxylin bodies were revealed in SLE patients. LE cells were observed in 2.6% of patients with RA but were not accompanied by ANA. Patients with SS, Still's disease, AS, Reiter's syndrome, and PA tested negative for LE cells. It appears from these results that LE cells are rarely present in the synovial fluid of patients with rheumatic diseases. In contrast, they occur in more than 40% of patients with the overlap syndrome and may thus be regarded as important for the diagnosis of this condition.

  19. A review of the consequences of fluid and electrolyte shifts in weightlessness

    NASA Technical Reports Server (NTRS)

    Leach, C. S.

    1979-01-01

    This review describes the renal-endocrine mechanisms related to the early losses of fluid-electrolytes from the body during weightlessness as well as their contribution to longer term adaptation of fluid-electrolyte balance. The hypotheses presented were generated by a systematic analysis of body fluid and renal dynamics observed under conditions of actual and simulated spaceflight. These have increased our understanding of the effects of acute headward fluid shifts on renal excretion, the factors promoting excess sodium excretion and the regulation of extracellular fluid composition.

  20. A review of the consequences of fluid and electrolyte shifts in weightlessness

    NASA Technical Reports Server (NTRS)

    Leach, C. S.

    1978-01-01

    This review describes the renal-endocrine mechanisms related to the early losses of fluid-electrolytes from the body during weightlessness as well as their contribution to longer term adaptation of fluid-electrolyte balance. The hypotheses presented were generated by a systematic analysis of body fluid and renal dynamics observed under conditions of actual and simulated spaceflight. These have increased our understanding of the effects of acute headward fluid shifts on renal excretion, the factors promoting excess sodium excretion and the regulation of extracellular fluid composition.

  1. Study Modules for Calculus-Based General Physics. [Includes Modules 11-14: Collisions; Equilibrium of Rigid Bodies; Rotational Dynamics; and Fluid Mechanics].

    ERIC Educational Resources Information Center

    Fuller, Robert G., Ed.; And Others

    This is part of a series of 42 Calculus Based Physics (CBP) modules totaling about 1,000 pages. The modules include study guides, practice tests, and mastery tests for a full-year individualized course in calculus-based physics based on the Personalized System of Instruction (PSI). The units are not intended to be used without outside materials;…

  2. Squid-inspired vehicle design using coupled fluid-solid analytical modeling

    NASA Astrophysics Data System (ADS)

    Giorgio-Serchi, Francesco; Weymouth, Gabriel

    2017-11-01

    The need for enhanced automation in the marine and maritime fields is fostering research into robust and highly maneuverable autonomous underwater vehicles. To address these needs we develop design principles for a new generation of soft-bodied aquatic vehicles similar to octopi and squids. In particular, we consider the capability of pulsed-jetting bodies to boost thrust by actively modifying their external body-shape and in this way benefit of the contribution from added-mass variation. We present an analytical formulation of the coupled fluid-structure interaction between the elastic body and the ambient fluid. The model incorporates a number of new salient contributions to the soft-body dynamics. We highlight the role of added-mass variation effects of the external fluid in enhancing thrust and assess how the shape-changing actuation is impeded by a confinement-related unsteady inertial term and by an external shape-dependent fluid stiffness contribution. We show how the analysis of these combined terms has guided us to the design of a new prototype of a squid-inspired vehicle tuning of the natural frequency of the coupled fluid-solid system with the purpose of optimizing its actuation routine.

  3. Clinical Assessment of Fluid Balance is Incomplete for Colorectal Surgical Patients.

    PubMed

    Tolstrup, J; Brandstrup, B

    2015-09-01

    Fluid balance for the surgical patient has been proven very important for the postoperative outcome and development of complications. The aim of this study was to evaluate, for the first time in modern times, the accordance between nurse-based fluid charting (cumulated fluid balance) and body weight change for general surgical patients. This was a descriptive study with prospectively collected data from two clinical randomized multicenter trials. A total of 113 patients from American Society of Anesthesiology group I-III undergoing elective colorectal surgery were included. Cumulated fluid balance and body weight change were charted preoperatively and daily at the same time during a postoperative period of 6 days. Differences were calculated by subtracting cumulated fluid balance from body weight change (1 g = 1 mL), and agreement was assessed by making Bland-Altman plots as well as Pearson correlations. From day 1 to 4, the mean difference between cumulated fluid balance and body weight change was below 0.4 kg/L. On day 5 and 6, the discrepancies increased with mean differences of, respectively, 1.2 kg/L (p < 0.002*) and 2 kg/L (p < 0.0001*). Bland-Altman plots showed increasingly poor agreement for all postoperative days with wide limits of agreement, ranging from more than 6 kg/L to almost 10 kg/L. Pearson correlations were moderate to strong at all times ranging from 0.437 (day 1) to 0.758 (day 4). The accordance between cumulated fluid balance and body weight change for colorectal surgical patients is relatively good for the first four postoperative days, however, with large uncertainty, whereas on the fifth and sixth postoperative day, the discrepancy is statistically and clinically significant. The fluid chart cannot stand alone in interpretation of the patient's fluid balance; body weight and clinical judgment is indispensable. © The Finnish Surgical Society 2014.

  4. In vitro evaluation of diamond-like carbon coatings with a Si/SiC x interlayer on surgical NiTi alloy

    NASA Astrophysics Data System (ADS)

    Liu, C. L.; Chu, Paul K.; Yang, D. Z.

    2007-04-01

    Diamond-like carbon (DLC) coatings were produced with a Si/SiCx interlayer by a hybrid plasma immersion ion implantation and deposition process to improve the adhesion between the carbon layer and surgical NiTi alloy substrate. The structure, mechanical properties, corrosion resistance and biocompatibility of the coatings were evaluated in vitro by Raman spectroscopy, pin-on-disk tests, potentiodynamic polarization tests and simulated fluid immersion tests. The DLC coatings with a Si/SiCx interlayer of a suitable thickness have better adhesion, lower friction coefficients and enhanced corrosion resistance. In the simulated body fluid tests, the coatings exhibit effective corrosion protection and good biocompatibility as indicated by PC12 cell cultures. DLC films fabricated on a Si/SiCx interlayer have high potential as protective coatings for biomedical NiTi materials.

  5. Effects of exercise on fluid exchange and body composition in man during 14-day bed rest

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Bernauer, E. M.; Juhos, L. T.; Young, H. L.; Morse, J. T.; Staley, R. W.

    1977-01-01

    A description is presented of an investigation in which body composition, fluid intake, and fluid and electrolyte losses were measured in seven normal, healthy men during three 2-wk bed-rest periods, separated by two 3-wk recovery periods. During bed rest the subjects remained in the horizontal position continuously. During the dietary control periods, body mass decreased significantly with all three regimens, including no exercise, isometric exercise, and isotonic excercise. During bed rest, body mass was essentially unchanged with no exercise, but decreased significantly with isotonic and isometric exercise. With one exception, there were no statistically significant changes in body density, lean body mass, or body fat content by the end of each of the three bed-rest periods.

  6. Comprehensive proteomic analysis of mineral nanoparticles derived from human body fluids and analyzed by liquid chromatography-tandem mass spectrometry.

    PubMed

    Martel, Jan; Young, David; Young, Andrew; Wu, Cheng-Yeu; Chen, Chi-De; Yu, Jau-Song; Young, John D

    2011-11-01

    Mineralo-protein nanoparticles (NPs) formed spontaneously in the body have been associated with ectopic calcifications seen in atherosclerosis, chronic degenerative diseases, and kidney stone formation. Synthetic NPs are also known to become coated with proteins when they come in contact with body fluids. Identifying the proteins found in NPs should help unravel how NPs are formed in the body and how NPs in general, be they synthetic or naturally formed, interact within the body. Here, we developed a proteomic approach based on liquid chromatography (LC) and tandem mass spectrometry (MS/MS) to determine the protein composition of carbonate-apatite NPs derived from human body fluids (serum, urine, cerebrospinal fluid, ascites, pleural effusion, and synovial fluid). LC-MS/MS provided not only an efficient and comprehensive determination of the protein constituents, but also a semiquantitative ranking of the identified proteins. Notably, the identified NP proteins mirrored the protein composition of the contacting body fluids, with albumin, fetuin-A, complement C3, α-1-antitrypsin, prothrombin, and apolipoproteins A1 and B-100 being consistently associated with the particles. Since several coagulation factors, calcification inhibitors, complement proteins, immune regulators, protease inhibitors, and lipid/molecule carriers can all become NP constituents, our results suggest that mineralo-protein complexes may interface with distinct biochemical pathways in the body depending on their protein composition. We propose that LC-MS/MS be used to characterize proteins found in both synthetic and natural NPs. Copyright © 2011 Elsevier Inc. All rights reserved.

  7. Bioassay of body fluids, experiment M073. [biochemical changes caused by space flight conditions

    NASA Technical Reports Server (NTRS)

    Leach, C. S.; Rambaut, P. C.

    1973-01-01

    Body fluids were assayed in this experiment to demonstrate changes which might have occurred during the 56-day chamber study in fluid and electrolyte balance, in regulation of calcium metabolism, in overall physiological and emotional adaptation to the environment, and in regulation of metabolic processes.

  8. A faster running speed is associated with a greater body weight loss in 100-km ultra-marathoners.

    PubMed

    Knechtle, Beat; Knechtle, Patrizia; Wirth, Andrea; Alexander Rüst, Christoph; Rosemann, Thomas

    2012-01-01

    In 219 recreational male runners, we investigated changes in body mass, total body water, haematocrit, plasma sodium concentration ([Na(+)]), and urine specific gravity as well as fluid intake during a 100-km ultra-marathon. The athletes lost 1.9 kg (s = 1.4) of body mass, equal to 2.5% (s = 1.8) of body mass (P < 0.001), 0.7 kg (s = 1.0) of predicted skeletal muscle mass (P < 0.001), 0.2 kg (s = 1.3) of predicted fat mass (P < 0.05), and 0.9 L (s = 1.6) of predicted total body water (P < 0.001). Haematocrit decreased (P < 0.001), urine specific gravity (P < 0.001), plasma volume (P < 0.05), and plasma [Na(+)] (P < 0.05) all increased. Change in body mass was related to running speed (r = -0.16, P < 0.05), change in plasma volume was associated with change in plasma [Na(+)] (r = -0.28, P < 0.0001), and change in body mass was related to both change in plasma [Na(+)] (r = -0.36) and change in plasma volume (r = 0.31) (P < 0.0001). The athletes consumed 0.65 L (s = 0.27) fluid per hour. Fluid intake was related to both running speed (r = 0.42, P < 0.0001) and change in body mass (r = 0.23, P = 0.0006), but not post-race plasma [Na(+)] or change in plasma [Na(+)] (P > 0.05). In conclusion, faster runners lost more body mass, runners lost more body mass when they drank less fluid, and faster runners drank more fluid than slower runners.

  9. Traces of illegal drugs on body surfaces: indicator for consumption or dealing?

    NASA Astrophysics Data System (ADS)

    Aberl, Franz; Bonenberger, Johannes; Berg, Ralf-Peter; Zimmermann, Rudolph; Sachs, Hans W.

    1997-01-01

    Customs investigation and drug enforcement services are interest in a rapid and reliable identification of smugglers and dealers. In contrast workplace testing and traffic controls are aiming at the detection of intoxicated persons via the determination of illegal narcotics in body fluids like urine or blood. DRUGWIPE is a pen size, test strip based immunochemical detector for narcotic contaminations on surfaces. It is extremely simple to apply and takes about two minutes to read test results without depending upon any further technical means. This paper describes the applicability of DRUGWIPE to identify drug smugglers or dealers as well as consumers. With respect to the situation and the initial suspicion the test indicates handling as well as consumption. In cooperation with the Institute for Legal Medicine in Munich suspicious drivers were examined with DRUGWIPE for the abuse of illegal narcotics. Test results from this test series are presented and compared with the results from the blood or urine analysis. The question whether the detected traces of illegal narcotics on the body surface of suspicious drivers are combing transpiration or external contamination are discussed.

  10. Analysis of DNA Methylation Status in Bodily Fluids for Early Detection of Cancer

    PubMed Central

    Yokoi, Keigo; Yamashita, Keishi; Watanabe, Masahiko

    2017-01-01

    Epigenetic alterations by promoter DNA hypermethylation and gene silencing in cancer have been reported over the past few decades. DNA hypermethylation has great potential to serve as a screening marker, a prognostic marker, and a therapeutic surveillance marker in cancer clinics. Some bodily fluids, such as stool or urine, were obtainable without any invasion to the body. Thus, such bodily fluids were suitable samples for high throughput cancer surveillance. Analyzing the methylation status of bodily fluids around the cancer tissue may, additionally, lead to the early detection of cancer, because several genes in cancer tissues are reported to be cancer-specifically hypermethylated. Recently, several studies that analyzed the methylation status of DNA in bodily fluids were conducted, and some of the results have potential for future development and further clinical use. In fact, a stool DNA test was approved by the U.S. Food and Drug Administration (FDA) for the screening of colorectal cancer. Another promising methylation marker has been identified in various bodily fluids for several cancers. We reviewed studies that analyzed DNA methylation in bodily fluids as a less-invasive cancer screening. PMID:28358330

  11. A systematic review of randomised controlled trials of the effects of warmed irrigation fluid on core body temperature during endoscopic surgeries.

    PubMed

    Jin, Yinghui; Tian, Jinhui; Sun, Mei; Yang, Kehu

    2011-02-01

    The purpose of this systematic review was to establish whether warmed irrigation fluid temperature could decrease the drop of body temperature and incidence of shivering and hypothermia. Irrigation fluid, which is used in large quantities during endoscopic surgeries at room temperature, is considered to be associated with hypothermia and shivering. It remains controversial whether using warmed irrigation fluid to replace room-temperature irrigation fluid will decrease the drop of core body temperature and the occurrence of hypothermia. A comprehensive search (computerised database searches, footnote chasing, citation chasing) was undertaken to identify all the randomised controlled trials that explored temperature of irrigation fluid in endoscopic surgery. An approach involving meta-analysis was used. We searched PubMed, EMBASE, Cochrane Library, SCI, China academic journals full-text databases, Chinese Biomedical Literature Database, Chinese scientific journals databases and Chinese Medical Association Journals for trials that meet the inclusion criteria. Study quality was assessed using standards recommended by Cochrane Library Handbook 5.0.1. Disagreement was resolved by consensus. Thirteen randomised controlled trials including 686 patients were identified. The results showed that room-temperature irrigation fluid caused a greater drop of core body temperature in patients, compared to warmed irrigation fluid (p < 0.00001; I(2) = 85%). The occurrence of shivering [odds ratio (OR) 5.13, 95% CI: 2.95-10.19, p < 0.00001; I(2) = 0%] and hypothermia (OR 22.01, 95% CI: 2.03-197.08, p = 0.01; I(2) = 64%) in the groups having warmed irrigation fluid were lower than the group of studies having room-temperature fluid. In endoscopic surgeries, irrigation fluid is recommended to be warmed to decrease the drop of core body temperature and the risk of perioperative shivering and hypothermia. Warming irrigating fluid should be considered standard practice in all endoscopic surgeries. © 2011 Blackwell Publishing Ltd.

  12. Many-Body Effects on the Thermodynamics of Fluids, Mixtures, and Nanoconfined Fluids.

    PubMed

    Desgranges, Caroline; Delhommelle, Jerome

    2015-11-10

    Using expanded Wang-Landau simulations, we show that taking into account the many-body interactions results in sharp changes in the grand-canonical partition functions of single-component systems, binary mixtures, and nanoconfined fluids. The many-body contribution, modeled with a 3-body Axilrod-Teller-Muto term, results in shifts toward higher chemical potentials of the phase transitions from low-density phases to high-density phases and accounts for deviations of more than, e.g., 20% of the value of the partition function for a single-component liquid. Using the statistical mechanics formalism, we analyze how this contribution has a strong impact on some properties (e.g., pressure, coexisting densities, and enthalpy) and a moderate impact on others (e.g., Gibbs or Helmholtz free energies). We also characterize the effect of the 3-body terms on adsorption isotherms and adsorption thermodynamic properties, thereby providing a full picture of the effect of the 3-body contribution on the thermodynamics of nanoconfined fluids.

  13. Applications of Modern Hydrodynamics to Aeronautics. Part 1: Fundamental Concepts and the Most Important Theorems. Part 2: Applications

    NASA Technical Reports Server (NTRS)

    Prandtl, L.

    1979-01-01

    A discussion of the principles of hydrodynamics of nonviscous fluids in the case of motion of solid bodies in a fluid is presented. Formulae are derived to demonstrate the transition from the fluid surface to a corresponding 'control surface'. The external forces are compounded of the fluid pressures on the control surface and the forces which are exercised on the fluid by any solid bodies which may be inside of the control surfaces. Illustrations of these formulae as applied to the acquisition of transformations from a known simple flow to new types of flow for other boundaries are given. Theoretical and experimental investigations of models of airship bodies are presented.

  14. Endocrine and fluid metabolism in males and females of different ages after bedrest, acceleration and lower body negative pressure

    NASA Technical Reports Server (NTRS)

    Leach, C. S.; Vernikos-Danellis, J.; Krauhs, J. M.; Sandler, H.

    1985-01-01

    Space shuttle flight simulations were conducted to determine the effects of weightlessness, lower body negative pressure (LBNP), and acceleration of fluid and electrolyte excretion and the hormones that control it. Measurements were made on male and female subjects of different ages before and after bedrest. After admission to a controlled environment, groups of 6 to 14 subjects in the age ranges 25 to 35, 35 to 45, 45 to 55 to 65 years were exposed to +3 G sub z for 15 minutes (G1) and to LBNP (LBNP1) on different days. On 3 days during this prebedrest period, no tests were conducted. Six days of bedrest followed, and the G sub z (G2) and LBNP (LBNP2) tests were run again. Hormones, electrolytes, and other parameters were measured in 24-hour urine pools throughout the experiment. During bedrest, cortisol and aldosterone excretion increased. Urine volume decreased, and specific gravity and osmolality increased. Urinary electrolytes were statistically unchanged from levels during the non-stress control period. During G2, cortisol increased significantly over its control and bedrest levels. Urine volume, sodium, and chloride were significantly lower; specific gravity and osmolality were higher during the control period or bedrest. The retention of fluids and electrolytes after +G sub z may at least partially explain decreased urine volume and increased osmolality observed during bedrest in this study. There were some who indicated that space flight would not affect the fluid and electrolyte metabolism of females or older males any more severely than it has affected that of male astronauts.

  15. A high-accuracy measurement method of glucose concentration in interstitial fluid based on microdialysis

    NASA Astrophysics Data System (ADS)

    Li, Dachao; Xu, Qingmei; Liu, Yu; Wang, Ridong; Xu, Kexin; Yu, Haixia

    2017-11-01

    A high-accuracy microdialysis method that can provide the reference values of glucose concentration in interstitial fluid for the accurate evaluation of non-invasive and minimally invasive continuous glucose monitoring is reported in this study. The parameters of the microdialysis process were firstly optimized by testing and analyzing three main factors that impact microdialysis recovery, including the perfusion rate, temperature, and glucose concentration in the area surrounding the microdialysis probe. The precision of the optimized microdialysis method was then determined in a simulation system that was designed and established in this study to simulate variations in continuous glucose concentration in the human body. Finally, the microdialysis method was tested for in vivo interstitial glucose concentration measurement.

  16. Fish robotics and hydrodynamics

    NASA Astrophysics Data System (ADS)

    Lauder, George

    2010-11-01

    Studying the fluid dynamics of locomotion in freely-swimming fishes is challenging due to difficulties in controlling fish behavior. To provide better control over fish-like propulsive systems we have constructed a variety of fish-like robotic test platforms that range from highly biomimetic models of fins, to simple physical models of body movements during aquatic locomotion. First, we have constructed a series of biorobotic models of fish pectoral fins with 5 fin rays that allow detailed study of fin motion, forces, and fluid dynamics associated with fin-based locomotion. We find that by tuning fin ray stiffness and the imposed motion program we can produce thrust both on the fin outstroke and instroke. Second, we are using a robotic flapping foil system to study the self-propulsion of flexible plastic foils of varying stiffness, length, and trailing edge shape as a means of investigating the fluid dynamic effect of simple changes in the properties of undulating bodies moving through water. We find unexpected non-linear stiffness-dependent effects of changing foil length on self-propelled speed, and as well as significant effects of trailing edge shape on foil swimming speed.

  17. Turbine endwall two-cylinder program. [wind tunnel and water tunnel investigation of three dimensional separation of fluid flow

    NASA Technical Reports Server (NTRS)

    Langston, L. S.

    1980-01-01

    Progress is reported in an effort to study the three dimensional separation of fluid flow around two isolated cylinders mounted on an endwall. The design and performance of a hydrogen bubble generator for water tunnel tests to determine bulk flow properties and to measure main stream velocity and boundary layer thickness are described. Although the water tunnel tests are behind schedule because of inlet distortion problems, tests are far enough along to indicate cylinder spacing, wall effects and low Reynolds number behavior, all of which impacted wind tunnel model design. The construction, assembly, and operation of the wind tunnel and the check out of its characteristics are described. An off-body potential flow program was adapted to calculate normal streams streamwise pressure gradients at the saddle point locations.

  18. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  19. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  20. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  1. 21 CFR 866.6010 - Tumor-associated antigen immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., plasma, urine, or other body fluids. This device is intended as an aid in monitoring patients for disease progress or response to therapy or for the detection of recurrent or residual disease. (b) Classification.... 866.6010 Section 866.6010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN...

  2. A prototype space flight intravenous injection system

    NASA Technical Reports Server (NTRS)

    Colombo, G. V.

    1985-01-01

    Medical emergencies, especially those resulting from accidents, frequently require the administration of intravenous fluids to replace lost body liquids. The development of a prototype space flight intravenous injection system is presented. The definition of requirements, injectable concentrates development, water polisher, reconstitution hardware development, administration hardware development, and prototype fabrication and testing are discussed.

  3. Evaluation of commercial kits for dual extraction of DNA and RNA from human body fluids.

    PubMed

    Schweighardt, Andrew J; Tate, Courtney M; Scott, Kristina A; Harper, Kathryn A; Robertson, James M

    2015-01-01

    STR typing of DNA evidence can identify the donor with a high power of discrimination but cannot identify the tissue origin of a body-fluid stain. Using RNA to attribute a crime scene stain to a particular tissue may aid in reconstruction efforts. With blood from 10 donors, four DNA and RNA coextraction kits were evaluated by measuring yields and STR and mRNA profiles. T tests indicated some significant differences in kit performance. The Zymo Research ZR-Duet(™) kit performed best based on average DNA (41.4 ng) and mRNA (4.07 ng) yields and was the only kit to provide complete DNA/RNA profiles for all samples. The consistency of this kit was challenged by data from additional blood and saliva donors. Further testing is advised before a superior kit is unequivocally chosen. Stand-alone DNA or RNA purification generally offers higher yield, but coextraction may still allow successful STR profiling and tissue source identification. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  4. EFFECTS OF EPISODIC SUBLUXATION EVENTS ON THIRD BODY INGRESS AND EMBEDMENT IN THE THA BEARING SURFACE

    PubMed Central

    Heiner, Anneliese D.; Lundberg, Hannah J.; Baer, Thomas E.; Pedersen, Douglas R.; Callaghan, John J.; Brown, Thomas D.

    2008-01-01

    In total joint arthroplasty, third body particle access to the articulating surfaces results in accelerated wear. Hip joint subluxation is an under-recognized means by which third body particles could potentially enter the otherwise closely conforming articular bearing space. The present study was designed to test the hypothesis that, other factors being equal, even occasional events of femoral head subluxation greatly increase the number of third body particles that enter the bearing space and become embedded in the acetabular liner, as compared to level walking cycles alone. Ten metal-on-polyethylene hip joint head-liner pairs were tested in a multi-axis joint motion simulator, with CoCrMo third body particles added to the synovial fluid analog. All component pairs were tested for two hours of level walking; half also were subjected to twenty intermittent subluxation events. The number and location of embedded particles on the acetabular liners were then determined. Subluxation dramatically increased the number of third body particles embedded in the acetabular liners, and it considerably increased the amount of scratch damage on the femoral heads. Since both third body particles and subluxation frequently occur in contemporary total hip arthroplasty, their potent synergy needs to be factored prominently into strategies to minimize wear. PMID:18561936

  5. Solid-on-solid contact in a sphere-wall collision in a viscous fluid

    NASA Astrophysics Data System (ADS)

    Birwa, Sumit Kumar; Rajalakshmi, G.; Govindarajan, Rama; Menon, Narayanan

    2018-04-01

    We study experimentally the collision between a sphere falling through a viscous fluid and a solid plate below. It is known that there is a well-defined threshold Stokes number above which the sphere rebounds from such a collision. Our experiment tests for direct contact between the colliding bodies and, contrary to prior theoretical predictions, shows that solid-on-solid contact occurs even for Stokes numbers just above the threshold for rebounding. The dissipation is fluid dominated, though details of the contact mechanics depend on the surface and bulk properties of the solids. Our experiments and a model calculation indicate that mechanical contact between the two colliding objects is generic and will occur for any realistic surface roughness.

  6. Study of Geometric Porosity on Static Stability and Drag Using Computational Fluid Dynamics for Rigid Parachute Shapes

    NASA Technical Reports Server (NTRS)

    Greathouse, James S.; Schwing, Alan M.

    2015-01-01

    This paper explores use of computational fluid dynamics to study the e?ect of geometric porosity on static stability and drag for NASA's Multi-Purpose Crew Vehicle main parachute. Both of these aerodynamic characteristics are of interest to in parachute design, and computational methods promise designers the ability to perform detailed parametric studies and other design iterations with a level of control previously unobtainable using ground or flight testing. The approach presented here uses a canopy structural analysis code to define the inflated parachute shapes on which structured computational grids are generated. These grids are used by the computational fluid dynamics code OVERFLOW and are modeled as rigid, impermeable bodies for this analysis. Comparisons to Apollo drop test data is shown as preliminary validation of the technique. Results include several parametric sweeps through design variables in order to better understand the trade between static stability and drag. Finally, designs that maximize static stability with a minimal loss in drag are suggested for further study in subscale ground and flight testing.

  7. [Athletic drinks: body rehydration as a vital aspect].

    PubMed

    Novokshanova, A L; Ozhiganova, E V

    2013-01-01

    106 students of the Faculty of Physical Education and athletes who train at the center of power arts (aged 18 to 30 years) have been investigated. The relation between the amount of lost and consumed liquid during physical activity has been studied. The amount of fluid lost was determined by the method of measuring the body mass of an athlete before and after the workout. The kinds of liquids used for eliminating dehydration have been analyzed. It has been revealed that while doing some physical activity and sports most of those being tested don't restore the lost liquid volume (with an average weight loss of 1,15 kg the amount of fluids they drunk was 0.91 l). In the given research the interrelation between the body weight and the lost liquid amount, and between the lost liquid amount and the kind of sports has not been exposed. Liquid loss of athletes in the medium intensive training process during the period of 1.5 h at the ambient temperature 21-22 degrees C constituted on average 1.53% of the body weight and didn't depend on the kind of sports. Despite the advantages of the athletic drinks are evident, the share of their consumption among the athletes in Russia is negligibly small. The great majority of respondents, namely 72%, use common or mineral water to restore the liquid. Only 6% of those being tested consume specialized athletic drinks.

  8. The effect of fluid and solid properties on the auxetic behavior of porous materials having rock-like microstructures

    DOE PAGES

    Wollner, U.; Vanorio, T.; Kiss, A. M.

    2017-09-30

    Materials with a negative Poisson's Ratio (PR), known as auxetics, exhibit the counterintuitive behavior of becoming wider when uniaxially stretched and thinner when compressed. Though negative PR is characteristic of polymer foams or cellular solids, tight as well as highly porous rocks have also been reported to exhibit negative PR. The paper proposes a novel auxetic structure based on pore-space configuration observed in rocks. We developed a theoretical auxetic 3D model consisting of rotating rigid bodies. To alleviate the mechanical assumption of rotating bodies, the theoretical model was modified to include crack-like features being represented by intersecting, elliptic cylinders. Wemore » then used a 3D printer to create a physical version of the modified model, whose PR was tested. We also numerically explored how the compressibility of fluids located in the pore-space of the modified model as well as how the elastic properties of the material from which the model is made of affect its auxetic behavior. Here, we conclude that for a porous medium composed of a single material saturated with a single fluid (a) the more compliant the fluid is and (b) the lower the PR of the solid material, the lower the PR value of the composite material.« less

  9. The effect of fluid and solid properties on the auxetic behavior of porous materials having rock-like microstructures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wollner, U.; Vanorio, T.; Kiss, A. M.

    Materials with a negative Poisson's Ratio (PR), known as auxetics, exhibit the counterintuitive behavior of becoming wider when uniaxially stretched and thinner when compressed. Though negative PR is characteristic of polymer foams or cellular solids, tight as well as highly porous rocks have also been reported to exhibit negative PR. The paper proposes a novel auxetic structure based on pore-space configuration observed in rocks. We developed a theoretical auxetic 3D model consisting of rotating rigid bodies. To alleviate the mechanical assumption of rotating bodies, the theoretical model was modified to include crack-like features being represented by intersecting, elliptic cylinders. Wemore » then used a 3D printer to create a physical version of the modified model, whose PR was tested. We also numerically explored how the compressibility of fluids located in the pore-space of the modified model as well as how the elastic properties of the material from which the model is made of affect its auxetic behavior. Here, we conclude that for a porous medium composed of a single material saturated with a single fluid (a) the more compliant the fluid is and (b) the lower the PR of the solid material, the lower the PR value of the composite material.« less

  10. Experimental measure of retinal impact force resulting from intraocular foreign body dropped onto retina through media of differing viscosity.

    PubMed

    Ernst, Benjamin J; Velez-Montoya, Raul; Kujundzic, Damir; Kujundzic, Elmira; Olson, Jeffrey L

    2013-07-01

    To evaluate and compare the perfluorocarbon liquid, silicone oil, and viscoelastic against standard saline, in their ability to dampen the impact force of a foreign body, dropped within the eye. In an experimental surgical model in where cohesive and adhesive forces of the substances are not enough to float heavy-than-water foreign bodies. A model of ophthalmic surgery was constructed. A BB pellet was dropped from 24 mm onto a force transducer through four different fluids: balanced salt solution, perfluoro-n-octane, viscoelastic, and silicone oil. The impact energy (force) for each case was measured and recorded by the force transducer. The mean force of impact for each fluid was compared using the Student t-test. Silicone oil resulted in the lowest force of impact. Both silicone oil and viscoelastic dampened the impact an order of magnitude more than perfluoro-n-octane and balanced salt solution. Silicone oil and viscoelastic cushioned the force from a dropped BB. They may be useful adjuncts to prevent iatrogenic retinal injury during vitrectomy for intraocular foreign body removal. © 2012 The Authors. Clinical and Experimental Ophthalmology © 2012 Royal Australian and New Zealand College of Ophthalmologists.

  11. Effects of rehydration fluid temperature and composition on body weight retention upon voluntary drinking following exercise-induced dehydration

    PubMed Central

    Bae, Yoon Jung; Lee, Yong Soo; Kim, Byeong Jo

    2012-01-01

    The purpose of this study was to determine the effects of beverage temperature and composition on weight retention and fluid balance upon voluntary drinking following exercise induced-dehydration. Eight men who were not acclimated to heat participated in four randomly ordered testing sessions. In each session, the subjects ran on a treadmill in a chamber maintained at 37℃ without being supplied fluids until 2% body weight reduction was reached. After termination of exercise, they recovered for 90 min under ambient air conditions and received one of the following four test beverages: 10℃ water (10W), 10℃ sports drink (10S), 26℃ water (26W), and 26℃ sports drink (26S). They consumed the beverages ad libitum. The volume of beverage consumed and body weight were measured at 30, 60, and 90 min post-recovery. Blood samples were taken before and immediately after exercise as well as at the end of recovery in order to measure plasma parameters and electrolyte concentrations. We found that mean body weight decreased by 1.8-2.0% following exercise. No differences in mean arterial pressure, plasma volume, plasma osmolality, and blood electrolytes were observed among the conditions. Total beverage volumes consumed were 1,164 ± 388, 1,505 ± 614, 948 ± 297, and 1,239 ± 401 ml for 10W, 10S, 26W, and 26S respectively (P > 0.05). Weight retention at the end of recovery from dehydration was highest in 10S (1.3 ± 0.7 kg) compared to 10W (0.4 ± 0.5 kg), 26W (0.4 ± 0.4 kg), and (0.6 ± 0.4 kg) (P < 0.005). Based on these results, carbohydrate/electrolyte-containing beverages at cool temperature were the most favorable for consumption and weight retention compared to plain water and moderate temperature beverages. PMID:22586501

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schlanderer, Stefan C., E-mail: stefan.schlanderer@unimelb.edu.au; Weymouth, Gabriel D., E-mail: G.D.Weymouth@soton.ac.uk; Sandberg, Richard D., E-mail: richard.sandberg@unimelb.edu.au

    This paper introduces a virtual boundary method for compressible viscous fluid flow that is capable of accurately representing moving bodies in flow and aeroacoustic simulations. The method is the compressible extension of the boundary data immersion method (BDIM, Maertens & Weymouth (2015), ). The BDIM equations for the compressible Navier–Stokes equations are derived and the accuracy of the method for the hydrodynamic representation of solid bodies is demonstrated with challenging test cases, including a fully turbulent boundary layer flow and a supersonic instability wave. In addition we show that the compressible BDIM is able to accurately represent noise radiation frommore » moving bodies and flow induced noise generation without any penalty in allowable time step.« less

  13. Rapid Identification and Multiple Susceptibility Testing of Pathogens from Positive-Culture Sterile Body Fluids by a Combined MALDI-TOF Mass Spectrometry and Vitek Susceptibility System

    PubMed Central

    Tian, Yueru; Zheng, Bing; Wang, Bei; Lin, Yong; Li, Min

    2016-01-01

    Infections of the bloodstream, central nervous system, peritoneum, joints, and other sterile areas are associated with high morbidity and sequelae risk. Timely initiation of effective antimicrobial therapy is crucial to improving patient prognosis. However, standard final identification and antimicrobial susceptibility tests (ASTs) are reported 16–48 h after a positive alert. For a rapid, effective and low-cost diagnosis, we combined matrix-assisted laser desorption/ionization time of flight mass spectrometry with a Vitek AST system, and performed rapid microbial identification (RMI) and rapid multiple AST (RMAST) on non-duplicated positive body fluid cultures collected from a hospital in Shanghai, China. Sterile body fluid positive culture and blood positive culture caused by Gram negative (GN) or polymicrobial were applied to the MALDI–TOF measurement directly. When positive blood culture caused by Gram positive (GP) bacteria or yeasts, they were resuspended in 1 ml brain heart infusion for 2 or 4 h enrichment, respectively. Regardless of enrichment, the RMI (completed in 40 min per sample) accurately identified GN and GP bacteria (98.9 and 87.2%, respectively), fungi (75.7%), and anaerobes (94.7%). Dominant species in multiple cultures and bacteria that failed to grow on the routing plates were correctly identified in 81.2 and 100% of cases, respectively. The category agreements of RMAST results, determined in the presence of various antibiotics, were similarly to previous studies. The RMI and RMAST results not only reduce the turnaround time of the patient report by 18–36 h, but also indicate whether a patient's antibiotic treatment should be accelerated, ceased or de-escalated, and adjusted the essential drugs modification for an optimized therapy. PMID:27148212

  14. Influence of pH, particle size and crystal form on dissolution behaviour of engineered nanomaterials.

    PubMed

    Avramescu, M-L; Rasmussen, P E; Chénier, M; Gardner, H D

    2017-01-01

    Solubility is a critical component of physicochemical characterisation of engineered nanomaterials (ENMs) and an important parameter in their risk assessments. Standard testing methodologies are needed to estimate the dissolution behaviour and biodurability (half-life) of ENMs in biological fluids. The effect of pH, particle size and crystal form on dissolution behaviour of zinc metal, ZnO and TiO 2 was investigated using a simple 2 h solubility assay at body temperature (37 °C) and two pH conditions (1.5 and 7) to approximately frame the pH range found in human body fluids. Time series dissolution experiments were then conducted to determine rate constants and half-lives. Dissolution characteristics of investigated ENMs were compared with those of their bulk analogues for both pH conditions. Two crystal forms of TiO 2 were considered: anatase and rutile. For all compounds studied, and at both pH conditions, the short solubility assays and the time series experiments consistently showed that biodurability of the bulk analogues was equal to or greater than biodurability of the corresponding nanomaterials. The results showed that particle size and crystal form of inorganic ENMs were important properties that influenced dissolution behaviour and biodurability. All ENMs and bulk analogues displayed significantly higher solubility at low pH than at neutral pH. In the context of classification and read-across approaches, the pH of the dissolution medium was the key parameter. The main implication is that pH and temperature should be specified in solubility testing when evaluating ENM dissolution in human body fluids, even for preliminary (tier 1) screening.

  15. Lunar Fluid Core and Solid-Body Tides

    NASA Technical Reports Server (NTRS)

    Williams, J. G.; Boggs, D. H.; Ratcliff, J. T.

    2005-01-01

    Variations in rotation and orientation of the Moon are sensitive to solid-body tidal dissipation, dissipation due to relative motion at the fluid-core/solid-mantle boundary, and tidal Love number k2 [1,2]. There is weaker sensitivity to flattening of the core-mantle boundary (CMB) [2-5] and fluid core moment of inertia [1]. Accurate Lunar Laser Ranging (LLR) measurements of the distance from observatories on the Earth to four retroreflector arrays on the Moon are sensitive to lunar rotation and orientation variations and tidal displacements. Past solutions using the LLR data have given results for dissipation due to solid-body tides and fluid core [1] plus Love number [1-5]. Detection of CMB flattening has been improving [3,5] and now seems significant. This strengthens the case for a fluid lunar core.

  16. Appropriate Mechanochemical Conditions for Corrosion-Fatigue Testing of Magnesium Alloys for Temporary Bioimplant Applications

    NASA Astrophysics Data System (ADS)

    Harandi, Shervin Eslami; Singh Raman, R. K.

    2015-05-01

    Magnesium (Mg) alloys possess great potential as bioimplants. A temporary implant employed as support for the repair of a fractured bone must possess sufficient strength to maintain their mechanical integrity for the required duration of healing. However, Mg alloys are susceptible to sudden cracking or fracture under the simultaneous action of cyclic loading and the corrosive physiological environment, i.e., corrosion fatigue (CF). Investigations of such fracture should be performed under appropriate mechanochemical conditions that appropriately simulate the actual human body conditions. This article reviews the existing knowledge on CF of Mg alloys in simulated body fluid and describes a relatively more accurate testing procedure developed in the authors' laboratory.

  17. Medical Products Research

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Ventrex Laboratories, Inc. develops, manufactures and markets a line of medical diagnostic assays based on biochemical techniques, in particular immunochemical techniques. Their products are sold worldwide to hospitals and medical laboratories for use in testing blood samples and other biological fluids. Analysis of a patient's body fluids, compared with normal values, aids a physician in confirming or otherwise diagnosing a suspected disease condition. NERAC's rapid information retrieval has provided Ventrex invaluable up-to-date information, and has permitted large scale savings. NERAC's service was particularly important in the development of a new product in the company's Ventre/Sep line, which is used in radioimmunoassays.

  18. Feeding of swimming Paramecium with fore-aft asymmetry in viscous fluid

    NASA Astrophysics Data System (ADS)

    Zhang, Peng; Jana, Saikat; Giarra, Matthew; Vlachos, Pavlos; Jung, Sunghwan

    2013-11-01

    Swimming behaviours and feeding efficiencies of Paramecium Multimicronucleatum with fore-aft asymmetric body shapes are studied experimentally and numerically. Among various possible swimming ways, ciliates typically exhibit only one preferred swimming directions in favorable conditions. Ciliates, like Paramecia, with fore-aft asymmetric shapes preferably swim towards the slender anterior while feeding fluid to the oral groove located at the center of the body. Since both feeding and swimming efficiencies are influenced by fluid motions around the body, it is important to reveal the fluid mechanics around a moving object. Experimentally, μ-PIV methods are employed to characterize the source-dipole streamline patterns and fluid motions around Paramecium. Numerical simulations by boundary element methods are also used to evaluate surface stresses and velocities, which give insights into the efficiencies of swimming and feeding depending on body asymmetry. It is concluded that a slender anterior and fat posterior increases the combined efficiency of swimming and feeding, which matches well with actual shapes of Paramecium. Discrepancies between experiments and simulations are also discussed.

  19. Hydration and performance during Ramadan.

    PubMed

    Maughan, R J; Shirreffs, S M

    2012-01-01

    In the absence of any food or fluid intake during the hours of daylight during the month of Ramadan, a progressive loss of body water will occur over the course of each day, though these losses can be completely replaced each night. Large body water deficits will impair both physical and cognitive performance. The point at which water loss will begin to affect performance is not well defined, but it may be as little as 1-2% of body mass. For resting individuals in a temperate environment, the water loss that occurs during a day without food or fluid will typically amount to about 1% of body mass by the time of sunset. This small loss of body water is unlikely to have a major adverse effect on any aspect of physical or cognitive performance. Larger body water losses will occur, however, in hot weather or if exercise is undertaken. Performance in events lasting about 1 hour or longer may be impaired in the absence of fluid intake during the event. In weight-category sports, there may be difficulties due to the impossibility of restoring body water content between the weigh-in and competition, and athletes will require alternative strategies. Where more than one competition or training session takes place in a single day and where substantial fluid losses are incurred, recovery will be impaired by the absence of fluid intake.

  20. Entropy production in a fluid-solid system far from thermodynamic equilibrium.

    PubMed

    Chung, Bong Jae; Ortega, Blas; Vaidya, Ashwin

    2017-11-24

    The terminal orientation of a rigid body in a moving fluid is an example of a dissipative system, out of thermodynamic equilibrium and therefore a perfect testing ground for the validity of the maximum entropy production principle (MaxEP). Thus far, dynamical equations alone have been employed in studying the equilibrium states in fluid-solid interactions, but these are far too complex and become analytically intractable when inertial effects come into play. At that stage, our only recourse is to rely on numerical techniques which can be computationally expensive. In our past work, we have shown that the MaxEP is a reliable tool to help predict orientational equilibrium states of highly symmetric bodies such as cylinders, spheroids and toroidal bodies. The MaxEP correctly helps choose the stable equilibrium in these cases when the system is slightly out of thermodynamic equilibrium. In the current paper, we expand our analysis to examine i) bodies with fewer symmetries than previously reported, for instance, a half-ellipse and ii) when the system is far from thermodynamic equilibrium. Using two-dimensional numerical studies at Reynolds numbers ranging between 0 and 14, we examine the validity of the MaxEP. Our analysis of flow past a half-ellipse shows that overall the MaxEP is a good predictor of the equilibrium states but, in the special case of the half-ellipse with aspect ratio much greater than unity, the MaxEP is replaced by the Min-MaxEP, at higher Reynolds numbers when inertial effects come into play. Experiments in sedimentation tanks and with hinged bodies in a flow tank confirm these calculations.

  1. Corrosion mechanism and model of pulsed DC microarc oxidation treated AZ31 alloy in simulated body fluid

    NASA Astrophysics Data System (ADS)

    Gu, Yanhong; Chen, Cheng-fu; Bandopadhyay, Sukumar; Ning, Chengyun; Zhang, Yongjun; Guo, Yuanjun

    2012-06-01

    This paper addresses the effect of pulse frequency on the corrosion behavior of microarc oxidation (MAO) coatings on AZ31 Mg alloys in simulated body fluid (SBF). The MAO coatings were deposited by a pulsed DC mode at four different pulse frequencies of 300 Hz, 500 Hz, 1000 Hz and 3000 Hz with a constant pulse ratio. Potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) tests were used for corrosion rate and electrochemical impedance evaluation. The corroded surfaces were examined by X-ray diffraction (XRD), X-ray fluorescence (XRF) and optical microscopy. All the results exhibited that the corrosion resistance of MAO coating produced at 3000 Hz is superior among the four frequencies used. The XRD spectra showed that the corrosion products contain hydroxyapatite, brucite and quintinite. A model for corrosion mechanism and corrosion process of the MAO coating on AZ31 Mg alloy in the SBF is proposed.

  2. STUDIES ON SCRUB TYPHUS

    PubMed Central

    Smadel, Joseph E.; Rights, Fred L.; Jackson, Elizabeth B.

    1946-01-01

    A complement-fixing antigen specific for scrub typhus occurs in the body fluids and tissues of infected mice, white rats, and cotton rats. The specific serological substance is demonstrable only in those animals which develop a rapidly fatal disease after an incubation period of a few days. Such an experimental infection is induced in mice and rats by the intravenous injection of suspensions of yolk sac rich in R. orientalis. Ether extraction is an important step in the preparation of a complement-fixing antigen from tissues of mice dying with scrub typhus. The Imphal No. 8 and Calcutta strains of R. orientalis are indistinguishable on the basis of complement fixation and cross-immunity tests. The complement-fixing antigen in body fluids of infected mice and rats and in our preparations of tissues from such animals occurs as a soluble antigen. Under the proper conditions the soluble antigen can be stored or dehydrated without loss of serological activity. PMID:19871518

  3. Body fluid levels of neuroactive amino acids in autism spectrum disorders: a review of the literature.

    PubMed

    Zheng, Hui-Fei; Wang, Wen-Qiang; Li, Xin-Min; Rauw, Gail; Baker, Glen B

    2017-01-01

    A review of studies on the body fluid levels of neuroactive amino acids, including glutamate, glutamine, taurine, gamma-aminobutyric acid (GABA), glycine, tryptophan, D-serine, and others, in autism spectrum disorders (ASD) is given. The results reported in the literature are generally inconclusive and contradictory, but there has been considerable variation among the previous studies in terms of factors such as age, gender, number of subjects, intelligence quotient, and psychoactive medication being taken. Future studies should include simultaneous analyses of a large number of amino acids [including D-serine and branched-chain amino acids (BCAAs)] and standardization of the factors mentioned above. It may also be appropriate to use saliva sampling to detect amino acids in ASD patients in the future-this is noninvasive testing that can be done easily more frequently than other sampling, thus providing more dynamic monitoring.

  4. Tilted pillar array fabrication by the combination of proton beam writing and soft lithography for microfluidic cell capture: Part 1 Design and feasibility.

    PubMed

    Rajta, Istvan; Huszánk, Robert; Szabó, Atilla T T; Nagy, Gyula U L; Szilasi, Szabolcs; Fürjes, Peter; Holczer, Eszter; Fekete, Zoltan; Járvás, Gabor; Szigeti, Marton; Hajba, Laszlo; Bodnár, Judit; Guttman, Andras

    2016-02-01

    Design, fabrication, integration, and feasibility test results of a novel microfluidic cell capture device is presented, exploiting the advantages of proton beam writing to make lithographic irradiations under multiple target tilting angles and UV lithography to easily reproduce large area structures. A cell capture device is demonstrated with a unique doubly tilted micropillar array design for cell manipulation in microfluidic applications. Tilting the pillars increased their functional surface, therefore, enhanced fluidic interaction when special bioaffinity coating was used, and improved fluid dynamic behavior regarding cell culture injection. The proposed microstructures were capable to support adequate distribution of body fluids, such as blood, spinal fluid, etc., between the inlet and outlet of the microfluidic sample reservoirs, offering advanced cell capture capability on the functionalized surfaces. The hydrodynamic characteristics of the microfluidic systems were tested with yeast cells (similar size as red blood cells) for efficient capture. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Fluid Shifts

    NASA Technical Reports Server (NTRS)

    Stenger, Michael; Hargens, A.; Dulchavsky, S.; Ebert, D.; Lee, S.; Sargsyan, A.; Martin, D.; Lui, J.; Macias, B.; Arbeille, P.; hide

    2014-01-01

    NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 30% of ISS astronauts experience more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the space flight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration space flight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during space flight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's pre-flight condition and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome. This study has been selected for flight implementation and is one of the candidate investigations being considered for the one year mission.

  6. Fluid Shifts

    NASA Technical Reports Server (NTRS)

    Stenger, M.; Hargens, A.; Dulchavsky, S.; Ebert, D.; Lee, S.; Lauriie, S.; Garcia, K.; Sargsyan, A.; Martin, D.; Ribeiro, L.; hide

    2016-01-01

    NASA is focusing on long-duration missions on the International Space Station (ISS) and future exploration-class missions beyond low-Earth orbit. Visual acuity changes observed after short-duration missions were largely transient, but more than 50% of ISS astronauts experienced more profound, chronic changes with objective structural and functional findings such as papilledema and choroidal folds. Globe flattening, optic nerve sheath dilation, and optic nerve tortuosity also are apparent. This pattern is referred to as the visual impairment and intracranial pressure (VIIP) syndrome. VIIP signs and symptoms, as well as postflight lumbar puncture data, suggest that elevated intracranial pressure (ICP) may be associated with the spaceflight-induced cephalad fluid shifts, but this hypothesis has not been tested. The purpose of this study is to characterize fluid distribution and compartmentalization associated with long-duration spaceflight, and to correlate these findings with vision changes and other elements of the VIIP syndrome. We also seek to determine whether the magnitude of fluid shifts during spaceflight, as well as the VIIP-related effects of those shifts, is predicted by the crewmember's preflight conditions and responses to acute hemodynamic manipulations (such as head-down tilt). Lastly, we will evaluate the patterns of fluid distribution in ISS astronauts during acute reversal of fluid shifts through application of lower body negative pressure (LBNP) interventions to characterize and explain general and individual responses. METHODS: We will examine a variety of physiologic variables in 10 long-duration ISS crewmembers using the test conditions and timeline presented in the Figure below. Measures include: (1) fluid compartmentalization (total body water by D2O, extracellular fluid by NaBr, intracellular fluid by calculation, plasma volume by CO rebreathe, interstitial fluid by calculation); (2) forehead/eyelids, tibia, calcaneus tissue thickness (by ultrasound); (3) vascular dimensions by ultrasound (jugular veins, cerebral and carotid arteries, vertebral arteries and veins, portal vein); (4) vascular dynamics by MRI (head/neck blood flow, cerebrospinal fluid pulsatility); (5) ocular measures (optical coherence tomography, intraocular pressure, 2-dimensional ultrasound including optic nerve sheath diameter, globe flattening, and retina-choroid thickness, Doppler ultrasound of ophthalmic and retinal arteries, and veins); (6) cardiac variables by ultrasound (inferior vena cava, tricuspid flow and tissue Doppler, pulmonic valve, stroke volume, right heart dimensions and function, four-chamber views); and (7) ICP measures (tympanic membrane displacement, distortion-product otoacoustic emissions, and ICP calculated by MRI). On the ground, acute head-down tilt will induce cephalad fluid shifts, whereas LBNP will oppose these shifts. Controlled Mueller maneuvers will manipulate cardiovascular variables. Through interventions applied before, during, and after flight, we intend to fully evaluate the relationship between fluid shifts and the VIIP syndrome.

  7. The interaction between a solid body and viscous fluid by marker-and-cell method

    NASA Technical Reports Server (NTRS)

    Cheng, R. Y. K.

    1976-01-01

    A computational method for solving nonlinear problems relating to impact and penetration of a rigid body into a fluid type medium is presented. The numerical techniques, based on the Marker-and-Cell method, gives the pressure and velocity of the flow field. An important feature in this method is that the force and displacement of the rigid body interacting with the fluid during the impact and sinking phases are evaluated from the boundary stresses imposed by the fluid on the rigid body. A sample problem of low velocity penetration of a rigid block into still water is solved by this method. The computed time histories of the acceleration, pressure, and displacement of the block show food agreement with experimental measurements. A sample problem of high velocity impact of a rigid block into soft clay is also presented.

  8. X-43A Fluid and Environmental Systems: Ground and Flight Operation and Lessons Learned

    NASA Technical Reports Server (NTRS)

    Vachon, Michael Jacob; Grindle, Thomas J.; St.John, Clinton W.; Dowdell, David B.

    2005-01-01

    The X-43A Hyper-X program demonstrated the first successful flights of an airframe integrated scramjet powered hypersonic vehicle. The X-43A vehicles established successive world records for jet-powered vehicles at speeds of Mach 7 and Mach 10. The X-43A vehicle is a subscale version of proposed hypersonic reconnaissance strike aircraft. Scaled down to a length of 12 ft (3.66 m), the lifting body design with high fineness ratio resulted in very small internal space available for fluid systems and their corresponding environmental conditioning systems. Safe testing and operation of the X-43A fluid and environmental systems was critical for mission success, not only for the safety of the flight crew in the NASA B-52B carrier aircraft, but also to maintain the reliability of vehicle systems while exposed to dynamics and hostile conditions encountered during the boost trajectory. The X-43A fluid and environmental systems successfully managed explosive, pyrophoric, inert, and very high pressure gases without incident. This report presents a summary of the checkout and flight validation of the X-43A fluid systems. The testing used for mission assurance is summarized. System performance during captive carry and launch flights is presented. The lessons learned are also discussed.

  9. Stress, Aging and Thirst

    NASA Technical Reports Server (NTRS)

    Greenleaf, John E.

    1998-01-01

    After growth during adolesence, total body water decreases progressively with aging from 65% of body weight to about 53% of body weight in the 70th decade; a majority of the loss occurs from the extracellular volume, from 42% to about 25%, respectively. Cellular volume also reaches equilibrium in the 70th decade at about 25% of body weight. Various stresses such as exercise, heat and attitude exposure, ad prior dehydration attenuate voluntary fluid intake (involuntary dehydration). Voluntary fluid intake appears to decrease with aging (involuntary dehydration in this sense aging can be considered as a stress. Kidney function and muscle mass (80% water) decrease somewhat with aging, and voluntary fluid intake (thirst) is also attenuated. Thirst is stimulated by increasing osmolality (hypernatremia) of the extracellular fluid and by decreased extracellular volume (mainly plasma volume) which act to increase intracellular fluid volume osmolality to activiate drinking. The latter decreases fluid compartment osmolality which ' It terminates drinking. However, this drinking mechanism seems to be attenuated with aging such that increasing plasma osmolality no longer stimulates fluid intake appropriately. Hypernatremia in the elderly has been associated all too frequently with greater incidence of bacterial infection and increased mortality. Involuntary dehydration can be overcome in young men by acclimation to an intermittent exercise-in-heat training program. Perhaps exercise training in the elderly would also increase voluntary fluid intake and increase muscle mass to enhance retention of water.

  10. Fluid intake and changes in limb volumes in male ultra-marathoners: does fluid overload lead to peripheral oedema?

    PubMed

    Bracher, Alexia; Knechtle, Beat; Gnädinger, Markus; Bürge, Jolanda; Rüst, Christoph Alexander; Knechtle, Patrizia; Rosemann, Thomas

    2012-03-01

    An increase in body mass due to oedema has been previously described. The aim of this study was to investigate a potential association between both fluid and electrolyte intake and the formation of peripheral oedemas. Fluid and electrolyte intakes and the changes in limb volumes in 50 male 100-km ultra-marathoners were measured. Pre- and post-race serum sodium concentration ([Na(+)]), serum aldosterone concentration, serum copeptin concentration, serum and urine osmolality and body mass were determined. Fluid intake, renal function parameters and urinary output, as well as the changes of volume in the extremities, were measured. The changes of volume in the limbs were measured using plethysmography. Serum [Na(+)] increased by 1.6%; body mass decreased by 1.9 kg. Serum copeptin and aldosterone concentrations were increased. The change in serum copeptin concentration and the change in serum [Na(+)] correlated positively; the change in serum [Na(+)] and body mass correlated negatively. A mean fluid intake of 0.58 L/h was positively related to running speed and negatively to post-race serum [Na(+)]. Total fluid intake was positively related to the changes in both arm and lower leg volumes. Running speed was positively associated with the changes in arm and lower leg volumes; race time was related to the changes in serum copeptin or aldosterone concentrations. To conclude, fluid intake was related to the changes in limb volumes, where athletes with an increased fluid intake developed an increase in limb volumes.

  11. Current conducting end plate of fuel cell assembly

    DOEpatents

    Walsh, Michael M.

    1999-01-01

    A fuel cell assembly has a current conducting end plate with a conductive body formed integrally with isolating material. The conductive body has a first surface, a second surface opposite the first surface, and an electrical connector. The first surface has an exposed portion for conducting current between a working section of the fuel cell assembly and the electrical connector. The isolating material is positioned on at least a portion of the second surface. The conductive body can have support passage(s) extending therethrough for receiving structural member(s) of the fuel cell assembly. Isolating material can electrically isolate the conductive body from the structural member(s). The conductive body can have service passage(s) extending therethrough for servicing one or more fluids for the fuel cell assembly. Isolating material can chemically isolate the one or more fluids from the conductive body. The isolating material can also electrically isolate the conductive body from the one or more fluids.

  12. Modular robot

    DOEpatents

    Ferrante, Todd A.

    1997-01-01

    A modular robot may comprise a main body having a structure defined by a plurality of stackable modules. The stackable modules may comprise a manifold, a valve module, and a control module. The manifold may comprise a top surface and a bottom surface having a plurality of fluid passages contained therein, at least one of the plurality of fluid passages terminating in a valve port located on the bottom surface of the manifold. The valve module is removably connected to the manifold and selectively fluidically connects the plurality of fluid passages contained in the manifold to a supply of pressurized fluid and to a vent. The control module is removably connected to the valve module and actuates the valve module to selectively control a flow of pressurized fluid through different ones of the plurality of fluid passages in the manifold. The manifold, valve module, and control module are mounted together in a sandwich-like manner and comprise a main body. A plurality of leg assemblies are removably connected to the main body and are removably fluidically connected to the fluid passages in the manifold so that each of the leg assemblies can be selectively actuated by the flow of pressurized fluid in different ones of the plurality of fluid passages in the manifold.

  13. Bio-corrosion and cytotoxicity studies on novel Zr 55Co 30Ti 15 and Cu 60Zr 20Ti 20 metallic glasses

    DOE PAGES

    Vincent, S.; Daiwile, A.; Devi, S. S.; ...

    2014-09-26

    Metallic glasses are a potential and compatible implant candidate for biomedical applications. In the present investigation, a comparative study between novel Zr 55Co 30Ti 15 and Cu 60Zr 20Ti 20 metallic glasses is carried out to evaluate in vitro biocompatibility using simulated body fluids. The bio-corrosion behavior of Zr- and Cu-based metallic glasses in different types of artificial body fluids such as artificial saliva solution, phosphate-buffered saline solution, artificial blood plasma solution, and Hank’s balanced saline solution is evaluated using potentiodynamic polarization studies at a constant body temperature of 310.15 K (37 °C). Surface morphology of samples after bio-corrosion experimentsmore » was observed by scanning electron microscopy. In vitro cytotoxicity test on glassy alloys were performed using human osteosarcoma cell line as per 10993-5 guidelines from International Organization for Standardization. As a result, the comparative study between Zr- and Cu-based glassy alloys provides vital information about the effect of elemental composition on biocompatibility of metallic glasses.« less

  14. Design and Development of Low-Cost Water Tunnel for Educational Purpose

    NASA Astrophysics Data System (ADS)

    Zahari, M.; Dol, S. S.

    2015-04-01

    The hydrodynamic behaviour of immersed body is essential in fluid dynamics study. Water tunnel is an example of facility required to provide a controlled condition for fluid flow research. The operational principle of water tunnel is quite similar to the wind tunnel but with different working fluid and higher flow-pumping capacity. Flow visualization in wind tunnel is more difficult to conduct as turbulent flows in wind dissipate quickly whilst water tunnel is more suitable for such purpose due to higher fluid viscosity and wide variety of visualization techniques can be employed. The present work focusses on the design and development of open flow water tunnel for the purpose of studying vortex-induced vibration from turbulent vortex shedding phenomenon. The water tunnel is designed to provide a steady and uniform flow speed within the test section area. Construction details are discussed for development of low-cost water tunnel for quantitative and qualitative fluid flow measurements. The water tunnel can also be used for educational purpose such as fluid dynamics class activity to provide quick access to visualization medium for better understanding of various turbulence motion learnt in class.

  15. Magnetic heat pump flow director

    NASA Technical Reports Server (NTRS)

    Howard, Frank S. (Inventor)

    1995-01-01

    A fluid flow director is disclosed. The director comprises a handle body and combed-teeth extending from one side of the body. The body can be formed of a clear plastic such as acrylic. The director can be used with heat exchangers such as a magnetic heat pump and can minimize the undesired mixing of fluid flows. The types of heat exchangers can encompass both heat pumps and refrigerators. The director can adjust the fluid flow of liquid or gas along desired flow directions. A method of applying the flow director within a magnetic heat pump application is also disclosed where the comb-teeth portions of the director are inserted into the fluid flow paths of the heat pump.

  16. Environmental Contamination and Persistence of Ebola Virus RNA in an Ebola Treatment Center.

    PubMed

    Poliquin, Philippe Guillaume; Vogt, Florian; Kasztura, Miriam; Leung, Anders; Deschambault, Yvon; Van den Bergh, Rafael; Dorion, Claire; Maes, Peter; Kamara, Abdul; Kobinger, Gary; Sprecher, Armand; Strong, James E

    2016-10-15

     Ebola viruses (EBOVs) are primarily transmitted by contact with infected body fluids. Ebola treatment centers (ETCs) contain areas that are exposed to body fluids through the care of patients suspected or confirmed to have EBOV disease. There are limited data documenting which areas/fomites within ETCs pose a risk for potential transmission. This study conducted environmental surveillance in 2 ETCs in Freetown, Sierra Leone, during the 2014-2016 West African Ebola outbreak.  ETCs were surveyed over a 3-week period. Sites to be swabbed were identified with input from field personnel. Swab samples were collected and tested for the presence of EBOV RNA. Ebola-positive body fluid-impregnated cotton pads were serially sampled.  General areas of both ETCs were negative for EBOV RNA. The immediate vicinity of patients was the area most likely to be positive for EBOV RNA. Personal protective equipment became positive during patient care, but chlorine solution washes rendered them negative.  Personal protective equipment and patient environs do become positive for EBOV RNA, but careful attention to decontamination seems to remove it. EBOV RNA was not detected in general ward spaces. Careful attention to decontamination protocols seems to be important in minimizing the presence of EBOV RNA within ETC wards. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  17. The effect of Nb addition on mechanical properties, corrosion behavior, and metal-ion release of ZrAlCuNi bulk metallic glasses in artificial body fluid.

    PubMed

    Qiu, C L; Liu, L; Sun, M; Zhang, S M

    2005-12-15

    Bulk metallic glasses (BMGs) of Zr(65 - x)Nb(x)- Cu(17.5)Ni(10)Al(7.5) with Nb = 0, 2, and 5 at % were prepared by copper mold casting. Compression tests reveal that the two BMGs containing Nb exhibited superior strength and plasticity to the base alloy. The corrosion behavior of the alloys obtained was investigated in artificial body fluid by electrochemical measurements. It was found that the addition of Nb significantly enhanced the corrosion resistance of the Zr-based BMG, as indicated by a remarkable increase in corrosion potential and pitting potential. XPS analysis revealed that the passive film formed after anodic polarization was enriched in aluminum oxide and depleted in phosphate ions for the BMGs containing Nb, which accounts for the improvement of corrosion resistance. On the other hand, metal-ion release of different BMGs were determined in PPb (ng/mL) level with inductively coupled plasma mass spectrometry (ICP-MS) after being immersed in artificial body fluid at 37 degrees C for 20 days. It was found that the addition of Nb considerably reduced the ion release of all kinds of metals of the base system. This is probably attributed to the promoting effect of Nb on a rapid formation of highly protective film.

  18. Overnight fluid shifts in subjects with and without obstructive sleep apnea

    PubMed Central

    Ding, Ning; Lin, Wei; Zhang, Xi-Long; Ding, Wen-Xiao; Gu, Bing; Ni, Bu-Qing; Zhang, Wei; Zhang, Shi-Jiang

    2014-01-01

    Objective To investigate the characteristics of baseline body fluid content and overnight fluid shifts between non-obstructive sleep apnea (non-OSA) and obstructive sleep apnea (OSA) subjects. Methods A case-controlled study was performed between February 2013 and January 2014, with 36 (18 OSA and 18 non-OSA) outpatients enrolled in this study. Polysomnographic parameters and results of body fluid were compared between the two groups. Results There were no differences in age, weight, and body mass index (BMI) between groups. Compared with the non-OSA group, OSA group had significantly higher neck circumference (NC) and fluid volume shift in the legs. OSA patients had higher left and right leg fluid indices than non-OSA subjects. There were significant correlations between apnoea-hypopnoea index and baseline fluid indices in both legs as well as the reduction in overnight change in both legs fluid volume. The increase in NC was also significantly correlated with the reduction in overnight change in both legs fluid volume, but not with the change in head and neck fluid volume. There were significant correlations between change in NC and increased fluid shifts in head and neck volume. Conclusions OSA patients had a higher baseline fluid content in both legs as compared with non-OSA subjects, which may be the basic factor with regards to fluid shifts in OSA patients. The increase in head and neck fluid shift volume did not directly correlate with the severity of OSA. PMID:25589967

  19. Prey handling using whole-body fluid dynamics in batoids.

    PubMed

    Wilga, Cheryl D; Maia, Anabela; Nauwelaerts, Sandra; Lauder, George V

    2012-02-01

    Fluid flow generated by body movements is a foraging tactic that has been exploited by many benthic species. In this study, the kinematics and hydrodynamics of prey handling behavior in little skates, Leucoraja erinacea, and round stingrays, Urobatis halleri, are compared using kinematics and particle image velocimetry. Both species use the body to form a tent to constrain the prey with the pectoral fin edges pressed against the substrate. Stingrays then elevate the head, which increases the volume between the body and the substrate to generate suction, while maintaining pectoral fin contact with the substrate. Meanwhile, the tip of the rostrum is curled upwards to create an opening where fluid is drawn under the body, functionally analogous to suction-feeding fishes. Skates also rotate the rostrum upwards although with the open rostral sides and the smaller fin area weaker fluid flow is generated. However, skates also use a rostral strike behavior in which the rostrum is rapidly rotated downwards pushing fluid towards the substrate to potentially stun or uncover prey. Thus, both species use the anterior portion of the body to direct fluid flow to handle prey albeit in different ways, which may be explained by differences in morphology. Rostral stiffness and pectoral fin insertion onto the rostrum differ between skates and rays and this corresponds to behavioral differences in prey handling resulting in distinct fluid flow patterns. The flexible muscular rostrum and greater fin area of stingrays allow more extensive use of suction to handle prey while the stiff cartilaginous rostrum of skates lacking extensive fin insertion is used as a paddle to strike prey as well as to clear away sand cover. Copyright © 2011 Elsevier GmbH. All rights reserved.

  20. Determinants of PCR performance (Xpert MTB/RIF), including bacterial load and inhibition, for TB diagnosis using specimens from different body compartments

    PubMed Central

    Theron, Grant; Peter, Jonny; Calligaro, Greg; Meldau, Richard; Hanrahan, Colleen; Khalfey, Hoosain; Matinyenya, Brian; Muchinga, Tapuwa; Smith, Liezel; Pandie, Shaheen; Lenders, Laura; Patel, Vinod; Mayosi, Bongani M.; Dheda, Keertan

    2014-01-01

    The determinants of Xpert MTB/RIF sensitivity, a widely used PCR test for the diagnosis of tuberculosis (TB) are poorly understood. We compared culture time-to-positivity (TTP; a surrogate of bacterial load), MTB/RIF TB-specific and internal positive control (IPC)-specific CT values, and clinical characteristics in patients with suspected TB who provided expectorated (n = 438) or induced sputum (n = 128), tracheal aspirates (n = 71), bronchoalveolar lavage fluid (n = 152), pleural fluid (n = 76), cerebral spinal fluid (CSF; n = 152), pericardial fluid (n = 131), or urine (n = 173) specimens. Median bacterial load (TTP in days) was the strongest associate of MTB/RIF positivity in each fluid. TTP correlated with CT values in pulmonary specimens but not extrapulmonary specimens (Spearman's coefficient 0.5043 versus 0.1437; p = 0.030). Inhibition affected a greater proportion of pulmonary specimens than extrapulmonary specimens (IPC CT > 34: 6% (47/731) versus 1% (4/381; p < 0.0001). Pulmonary specimens had greater load than extrapulmonary specimens [TTPs (interquartile range) of 11 (7–16) versus 22 (18–33.5) days; p < 0.0001]. HIV-infection was associated with a decreased likelihood of MTB/RIF-positivity in pulmonary specimens but an increased likelihood in extrapulmonary specimens. Mycobacterial load, which displays significant variation across different body compartments, is the main determinant of MTB/RIF-positivity rather than PCR inhibition. MTB/RIF CT is a poor surrogate of load in extrapulmonary specimens. PMID:25014250

  1. Beverage osmolality as a marker for maintaining appropriate body hydration.

    PubMed

    Sadowska, Anna; Świderski, Franciszek; Rakowska, Rita; Waszkiewicz-Robak, Bożena; Żebrowska-Krasuska, Małgorzata; Dybkowska, Ewa

    2017-01-01

    Osmolalities can be useful markers for determining whether given beverages are suited for maintaining an adequate hydration of the body. Losing 2% of body water relative to body mass reduces the efficiency of body function when undertaking physical effort by around 20%. Deficiencies in water intakes approaching 5-8% of body mass, double the impairment to the body’s physical and mental functioning, whereas at a level of 10% the body becomes incapable of performing any sort of physical effort. For such reasons the body’s hydration status is vital to its functioning. To asses osmolalities as measured in various types of commercially available mineral waters and non-alcoholic beverages containing different amounts of extracts. Test materials were commercially available mineral waters (of low, medium and high mineral content) along with juices, nectars and drinks that are isotonic, energising and those described as being ‘light’ and sparkling. Osmolality was measured by the 800CL Osmometer instrument from TridentMed whilst the RL-type refractometer was used for determining extract values. Isotonic drinks were found to have the same osmotic pressures as bodily fluids at 275 – 295 mOsm/kg water. The osmotic pressure in mineral waters depended on the extent of mineralisation and ranged from 13 mOsm / kg water (low mineral content) to 119 mOsm/kg water (high mineral content). Low osmolalities were also found in ‘light’ drinks (from 29.3 to 34 mOsm/kg water). Juices, nectars, energising drinks and colas typically have high sugar contents and have high osmolalities ranging 492 – 784 mOsm / kg water. Statistical analysis demonstrated significant associations (p < 0.05) between osmolalities and extract content in beverages as well as between osmolalities and mineral content in mineral waters. Upon factor analysis, it was possible to group the tested drinks according to similar osmolalities and extract content. Osmolalities measured in beverages are a marker that permits drinks to be classified into groups according to their tonicity and their ability to ensure that the body is properly hydrated; this becoming vital in cases when the body requires rapid body fluid replenishment.

  2. Digestive solubilization of sediment-associated pollutants: In vitro extraction vs. in vivo bioavailability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weston, D.P.; Mayer, L.M.

    1995-12-31

    A method using polychaete digestive fluids as a more biologically realistic extractant has recent been proposed as a means to quantify this bioavailable fraction. This work was intended to evaluate this approach with polynuclear aromatic hydrocarbons (PAH), and, in particular, to relate in vitro measures of PAH solubilization by digestive fluids to bioavailability as perceived by the whole animal. In tests with a variety of PAH-contaminated sediments, there were dramatic differences among the sediments in the amounts of PAH extracted by digestive fluids. About 50% of a PAH spike was extracted from a low organic carbon sediment during digestive fluidmore » extraction, while only 20% was extracted from a high organic carbon sediment. The relationships between these differences in PAH solubilization and true bioavailability were evaluated in polychaete bioaccumulation tests measuring PAH uptake rate coefficients and steady state body burdens. The work has also shown that desorption of PAH from ingested sediments in the whole animal approximated the quantities extracted in the in vitro tests. Moreover, desorption of PAH from ingested sediments was found to be greatest in that portion of the polychaete gut with the highest enzymatic activity and from which the digestive fluids had been collected. The digestive fluid extraction approach provides a new tool to examine digestive uptake of contaminants by manipulations that would be impossible in vivo, and may help to quantify a bioavailable contaminant fraction.« less

  3. Experimental Simulation of Shock Reequilibration of Fluid Inclusions During Meteorite Impact

    NASA Technical Reports Server (NTRS)

    Madden, M. E. Elwood; Hoerz, R. J.; Bodnar, R. J.

    2003-01-01

    Fluid inclusions are microscopic volumes of fluid trapped within minerals as they precipitate. Fluid inclusions are common in terrestrial minerals formed under a wide array of geological settings from surface evaporite deposits to kimberlite pipes. While fluid inclusions in terrestrial rocks are the rule rather than the exception, only few fluid inclusion-bearing meteorites have been documented. The rarity of fluid inclusions in meteoritic material may be explained in two ways. First, it may reflect the absence of fluids (water?) on meteorite parent bodies. Alternatively, fluids may have been present when the rock formed, but any fluid inclusions originally trapped on the parent body were destroyed by the extreme P-T conditions meteorites often experience during impact events. Distinguishing between these two possibilities can provide significant constraints on the likelihood of life on the parent body. Just as textures, structures, and compositions of mineral phases can be significantly altered by shock metamorphism upon hypervelocity impact, fluid inclusions contained within component minerals may be altered or destroyed due to the high pressures, temperatures, and strain rates associated with impact events. Reequilibration may occur when external pressure-temperature conditions differ significantly from internal fluid isochoric conditions, and result in changes in fluid inclusion properties and/or textures. Shock metamorphism and fluid inclusion reequilibration can affect both the impacted target material and the meteoritic projectile. By examining the effects of shock deformation on fluid inclusion properties and textures we may be able to better constrain the pressure-temperature path experienced by shocked materials and also gain a clearer understanding of why fluid inclusions are rarely found in meteoritic samples.

  4. Localized corrosion behaviour in simulated human body fluids of commercial Ni-Ti orthodontic wires.

    PubMed

    Rondelli, G; Vicentini, B

    1999-04-01

    The corrosion performances in simulated human body fluids of commercial equiatomic Ni-Ti orthodontic wires having various shape and size and produced by different manufacturers were evaluated; for comparison purposes wires made of stainless steel and of cobalt-based alloy were also examined. Potentiodynamic tests in artificial saliva at 40 degrees C indicated a sufficient pitting resistance for the Ni-Ti wires, similar to that of cobalt-based alloy wire; the stainless steel wire, instead, exhibited low pitting potential. Potentiodynamic tests at 40 degrees C in isotonic saline solution (0.9% NaCl) showed, for Ni-Ti and stainless steel wires, pitting potential values in the range approximately 200-400 mV and approximately 350 mV versus SCE, respectively: consequently, according to literature data (Hoar TP, Mears DC. Proc Roy Soc A 1996;294:486-510), these materials should be considered potentially susceptible to pitting; only the cobalt-based alloy should be immune from pitting. The localized corrosion potentials determined in the same environment by the ASTM F746 test (approximately 0-200 mV and 130 mV versus SCE for Ni-Ti and stainless steel, respectively) pointed out that for these materials an even higher risk of localized corrosion. Slight differences in localized corrosion behaviour among the various Ni-Ti wires were detected.

  5. Biofluid mechanics of special organs and the issue of system control. Sixth International Bio-Fluid Mechanics Symposium and Workshop, March 28-30, 2008 Pasadena, California.

    PubMed

    Zamir, Mair; Moore, James E; Fujioka, Hideki; Gaver, Donald P

    2010-03-01

    In the field of fluid flow within the human body, focus has been placed on the transportation of blood in the systemic circulation since the discovery of that system; but, other fluids and fluid flow phenomena pervade the body. Some of the most fascinating fluid flow phenomena within the human body involve fluids other than blood and a service other than transport--the lymphatic and pulmonary systems are two striking examples. While transport is still involved in both cases, this is not the only service which they provide and blood is not the only fluid involved. In both systems, filtration, extraction, enrichment, and in general some "treatment" of the fluid itself is the primary function. The study of the systemic circulation has also been conventionally limited to treating the system as if it were an open-loop system governed by the laws of fluid mechanics alone, independent of physiological controls and regulations. This implies that system failures can be explained fully in terms of the laws of fluid mechanics, which of course is not the case. In this paper we examine the clinical implications of these issues and of the special biofluid mechanics issues involved in the lymphatic and pulmonary systems.

  6. Portable Medical Diagnosis Instrument

    NASA Technical Reports Server (NTRS)

    Coleman, Matthew A. (Inventor); Straume, Tore (Inventor); Loftus, David J. (Inventor); Li, Jing (Inventor); Singh, Anup K. (Inventor); Davis, Cristina E. (Inventor)

    2017-01-01

    A system that integrates several technologies into a single, portable medical diagnostic apparatus for analyzing a sample body fluid (liquid and/or gas): (1) a mechanism to capture airborne microdroplets and to separate the body fluid into a first fluid component (primarily gas) and a second fluid component (primarily liquid); (2) a volatilizer to convert a portion of the second fluid component into a third fluid component that is primarily a gas; (3) a functionalized nanostructure (NS) array configured to receive, identify, and estimate concentration of at least one constituent in the first and/or third fluid components; (4) a miniaturized differential mobility spectrometer (DMS) module; and (5) a biomarker sensor, to detect volatile and non-volatile molecules in a sample fluid, which may contain one or more components of blood, breath, perspiration, saliva, and urine.

  7. Flutter Instability of a Fluid-Conveying Fluid-Immersed Pipe Affixed to a Rigid Body

    DTIC Science & Technology

    2011-01-01

    rigid body, denoted by y in Fig. 4, is small. This is in addition to the Euler– Bernoulli beam assumption that the slope of the tail is small everywhere...here. These include the efficiency with which the prime mover can generate fluid momentum , pipe losses, and external drag acting on both the hull and the

  8. Changes in body fluid compartments on re-induction to high altitude and effect of diuretics

    NASA Astrophysics Data System (ADS)

    Singh, M. V.; Rawal, S. B.; Tyagi, A. K.; Bhagat, Maj J. K.; Parshad, R.; Divekar, H. M.

    1988-03-01

    Studies were carried out in 29 healthy young adults in the Indian Army stationed in the plains and posted at an elevation of 3500 m for more than 6 months. After exposure to a low elevation in Delhi (260 m) for 3 weeks they were reinduced to a height of 3500 m. The subjects were divided into three groups, each of which was treated with either placebo or acetazolamide or spironolactone. The drug treatment was started immediately after their landing at high altitude and continued for 2 days only. Total body water, extracellular fluid, intracellular fluid, plasma volume, blood pH, PaO2, PaCO2 and blood viscosity were determined on exposure at Delhi and on re-induction to high altitude. Plasma volume was increased after the descent from high altitude and remained high for up to 21 day's study. This increased plasma volume may have some significance in the pathogenesis of pulmonary oedema. Total body water and intracellular fluid content were increased at 260 m elevation, while extracellular fluid decreased. On re-induction there was a decrease in total body water with no change in the extracellular fluid content.

  9. Does intra-abdominal fluid increase the resting energy expenditure?

    PubMed

    Zarling, E J; Grande, A; Hano, J

    1997-10-01

    In patients with intra-abdominal fluid collection, caloric needs are based on an estimated dry weight. This is done because intra-abdominal fluid has been assumed to be metabolically inactive. One recent study of patients with slowly resolving ascites suggested otherwise. In our study, the effect of intra-abdominal fluid on the resting energy expenditure (REE) and apparent lean body mass was determined in 10 stable patients requiring peritoneal dialysis. For each subject, in both the empty and full state, we measured REE by indirect calorimetry, and body composition by the bioelectric impedance method. In the full state, the VCO2 was significantly increased (210 +/- 11 versus 197 +/- 9 mL/min, P < 0.02) compared with the empty state. This caused an increase in the calculated resting energy expenditure (1531 +/- 88 kcal/d empty versus 1593 +/- 94 kcal/d full, P < 0.05). The magnitude of increase in REE was similar to the expected calories derived from glucose absorbed out of the dialysate. Estimates of body fat, lean body mass, and total water also were not affected by the intra-abdominal fluid. We conclude that intra-abdominal fluid will not affect the measured REE and hence may be considered to be metabolically inactive.

  10. Effect of lower-body positive pressure on postural fluid shifts in men

    NASA Technical Reports Server (NTRS)

    Hinghofer-Szalkay, H.; Kravik, S. E.; Greenleaf, J. E.

    1988-01-01

    The effect of the lower-body positive pressure (LBPP) on the orthostatic fluid and protein shifts were investigated in five men during combined tilt-table/antigravity suit inflation and deflation experiments. Changes in the mass densities of venous blood and plasma were measured and the values were used to calculate the densities of erythrocytes, whole-body blood, and shifted fluid. It was found that the application of 60 mm Hg LBPP during 60-deg head-up tilt prevented about half of the postural hemoconcentration occurring during passive head-up tilt.

  11. Elimination of cotinine from body fluids: implications for noninvasive measurement of tobacco smoke exposure.

    PubMed Central

    Jarvis, M J; Russell, M A; Benowitz, N L; Feyerabend, C

    1988-01-01

    Cotinine elimination from plasma, saliva, and urine was studied over 11 days in five subjects (three nonsmokers and two occasional smokers). Half-lives for cotinine averaged 16-19 hours in the different body fluids (range 10 to 27 hours between subjects). There was no tendency for the half-life in saliva to be longer than in plasma or urine. We conclude that choice of body fluid for cotinine assay in smoking studies should depend on practical rather than pharmacokinetic considerations. PMID:3369603

  12. Force, Surface Pressure, and Flowfield Measurements on a Slender Missile Configuration with Square Cross-Section at Supersonic Speeds

    NASA Technical Reports Server (NTRS)

    Wilcox, Floyd J., Jr.; Birch, Trevor J.; Allen, Jerry M.

    2004-01-01

    A wind-tunnel investigation of a square cross-section missile configuration has been conducted to obtain force and moment measurements, surface pressure measurements, and vapor screen flow visualization photographs for comparison with computational fluid dynamics studies conducted under the auspices of The Technical Cooperation Program (TTCP). Tests were conducted on three configurations which included: (1) body alone, (2) body plus tail fins mounted on the missile corners, and (3) body plus tail fins mounted on the missile side. This test was conducted in test section #2 of the NASA Langley Unitary Plan Wind Tunnel at Mach numbers of 2.50 and 4.50 and at a Reynolds number of 4 million per ft. The data were obtained over an angle of attack range from -4 deg. to 24 deg. and roll angles from 0 deg. to 45 deg., i.e., from a diamond shape (as viewed from the rear) at a roll angle of 0 deg. to a square shape at 45 deg.

  13. Assessment of extracellular dehydration using saliva osmolality.

    PubMed

    Ely, Brett R; Cheuvront, Samuel N; Kenefick, Robert W; Spitz, Marissa G; Heavens, Kristen R; Walsh, Neil P; Sawka, Michael N

    2014-01-01

    When substantial solute losses accompany body water an isotonic hypovolemia (extracellular dehydration) results. The potential for using blood or urine to assess extracellular dehydration is generally poor, but saliva is not a simple ultra-filtrate of plasma and the autonomic regulation of salivary gland function suggests the possibility that saliva osmolality (Sosm) may afford detection of extracellular dehydration via the influence of volume-mediated factors. This study aimed to evaluate the assessment of extracellular dehydration using Sosm. In addition, two common saliva collection methods and their effects on Sosm were compared. Blood, urine, and saliva samples were collected in 24 healthy volunteers during paired euhydration and dehydration trials. Furosemide administration and 12 h fluid restriction were used to produce extracellular dehydration. Expectoration and salivette collection methods were compared in a separate group of eight euhydrated volunteers. All comparisons were made using paired t-tests. The diagnostic potential of body fluids was additionally evaluated. Dehydration (3.1 ± 0.5% loss of body mass) decreased PV (-0.49 ± 0.12 L; -15.12 ± 3.94% change), but Sosm changes were marginal (<10 mmol/kg) and weakly correlated with changes in absolute or relative PV losses. Overall diagnostic accuracy was poor (AUC = 0.77-0.78) for all body fluids evaluated. Strong agreement was observed between Sosm methods (Expectoration: 61 ± 10 mmol/kg, Salivette: 61 ± 8 mmol/kg, p > 0.05). Extracelluar dehydration was not detectable using plasma, urine, or saliva measures. Salivette and expectoration sampling methods produced similar, consistent results for Sosm, suggesting no methodological influence on Sosm.

  14. A Circuit Model of Real Time Human Body Hydration.

    PubMed

    Asogwa, Clement Ogugua; Teshome, Assefa K; Collins, Stephen F; Lai, Daniel T H

    2016-06-01

    Changes in human body hydration leading to excess fluid losses or overload affects the body fluid's ability to provide the necessary support for healthy living. We propose a time-dependent circuit model of real-time human body hydration, which models the human body tissue as a signal transmission medium. The circuit model predicts the attenuation of a propagating electrical signal. Hydration rates are modeled by a time constant τ, which characterizes the individual specific metabolic function of the body part measured. We define a surrogate human body anthropometric parameter θ by the muscle-fat ratio and comparing it with the body mass index (BMI), we find theoretically, the rate of hydration varying from 1.73 dB/min, for high θ and low τ to 0.05 dB/min for low θ and high τ. We compare these theoretical values with empirical measurements and show that real-time changes in human body hydration can be observed by measuring signal attenuation. We took empirical measurements using a vector network analyzer and obtained different hydration rates for various BMI, ranging from 0.6 dB/min for 22.7 [Formula: see text] down to 0.04 dB/min for 41.2 [Formula: see text]. We conclude that the galvanic coupling circuit model can predict changes in the volume of the body fluid, which are essential in diagnosing and monitoring treatment of body fluid disorder. Individuals with high BMI would have higher time-dependent biological characteristic, lower metabolic rate, and lower rate of hydration.

  15. Hydrogen and Oxygen Stable Isotope Fractionation in Body Fluid Compartments of Dairy Cattle According to Season, Farm, Breed, and Reproductive Stage

    PubMed Central

    Abeni, Fabio; Petrera, Francesca; Capelletti, Maurizio; Dal Prà, Aldo; Bontempo, Luana; Tonon, Agostino; Camin, Federica

    2015-01-01

    Environmental temperature affects water turnover and isotope fractionation by causing water evaporation from the body in mammals. This may lead to rearrangement of the water stable isotope equilibrium in body fluids. We propose an approach to detect possible variations in the isotope ratio in different body fluids on the basis of different homoeothermic adaptations in varying reproductive stages. Three different reproductive stages (pregnant heifer, primiparous lactating cow, and pluriparous lactating cow) of two dairy cattle breeds (Italian Friesian and Modenese) were studied in winter and summer. Blood plasma, urine, faecal water, and milk were sampled and the isotope ratios of H (2H/1H) and O (18O/16O) were determined. Deuterium excess and isotope-fractionation factors were calculated for each passage from plasma to faeces, urine and milk. The effects of the season, reproductive stages and breed on δ 2H and δ 18O were significant in all the fluids, with few exceptions. Deuterium excess was affected by season in all the analysed fluids. The correlations between water isotope measurements in bovine body fluids ranged between 0.6936 (urine-milk) and 0.7848 (urine-plasma) for δ 2H, and between 0.8705 (urine-milk) and 0.9602 (plasma-milk) for δ 18O. The increase in both isotopic δ values in all body fluids during summer is representative of a condition in which fractionation took place as a consequence of a different ratio between ingested and excreted water, which leads to an increased presence of the heavy isotopes. The different body water turnover between adult lactating cattle and non-lactating heifers was confirmed by the higher isotopic δ for the latter, with a shift in the isotopic equilibrium towards values more distant from those of drinking water. PMID:25996911

  16. The Role of Clinical Proteomics, Lipidomics, and Genomics in the Diagnosis of Alzheimer's Disease.

    PubMed

    Martins, Ian James

    2016-03-31

    The early diagnosis of Alzheimer's disease (AD) has become important to the reversal and treatment of neurodegeneration, which may be relevant to premature brain aging that is associated with chronic disease progression. Clinical proteomics allows the detection of various proteins in fluids such as the urine, plasma, and cerebrospinal fluid for the diagnosis of AD. Interest in lipidomics has accelerated with plasma testing for various lipid biomarkers that may with clinical proteomics provide a more reproducible diagnosis for early brain aging that is connected to other chronic diseases. The combination of proteomics with lipidomics may decrease the biological variability between studies and provide reproducible results that detect a community's susceptibility to AD. The diagnosis of chronic disease associated with AD that now involves genomics may provide increased sensitivity to avoid inadvertent errors related to plasma versus cerebrospinal fluid testing by proteomics and lipidomics that identify new disease biomarkers in body fluids, cells, and tissues. The diagnosis of AD by various plasma biomarkers with clinical proteomics may now require the involvement of lipidomics and genomics to provide interpretation of proteomic results from various laboratories around the world.

  17. Differentiation of five body fluids from forensic samples by expression analysis of four microRNAs using quantitative PCR.

    PubMed

    Sauer, Eva; Reinke, Ann-Kathrin; Courts, Cornelius

    2016-05-01

    Applying molecular genetic approaches for the identification of forensically relevant body fluids, which often yield crucial information for the reconstruction of a potential crime, is a current topic of forensic research. Due to their body fluid specific expression patterns and stability against degradation, microRNAs (miRNA) emerged as a promising molecular species, with a range of candidate markers published. The analysis of miRNA via quantitative Real-Time PCR, however, should be based on a relevant strategy of normalization of non-biological variances to deliver reliable and biologically meaningful results. The herein presented work is the as yet most comprehensive study of forensic body fluid identification via miRNA expression analysis based on a thoroughly validated qPCR procedure and unbiased statistical decision making to identify single source samples. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Noninvasive estimation of fluid shifts between body compartments by measurement of bioelectric characteristics

    NASA Technical Reports Server (NTRS)

    Bishop, Phillip A.

    1989-01-01

    Previous research has established that bioelectrical characteristics of the human body reflect fluid status to some extent. It has been previously assumed that changes in electrical resistance (R) and reactance (X) are associated with changes in total body water (TBW). The purpose of the present pilot investigation was to assess the correspondence between body R and X and changes in estimated TBW and plasma volume during a period of bedrest (simulated weightlessness). R and X were measured pre-, during, and post- a 13 day bedrest status. Although a clear relationship was not elucidated, evidence was found suggesting that R and X reflect plasma volume rather than TBW. Indirect evidence provided by previous studies which investigated other aspects of the electrical/fluid relationship, also suggests the independence of TBW and electrical properties. With further research, a bioelectrical technique for noninvasively tracking fluid changes consequent to space flight may be developed.

  19. Regulation of body fluid and salt homeostasis--from observations in space to new concepts on Earth.

    PubMed

    Gerzer, R; Heer, M

    2005-08-01

    The present manuscript summarizes recent discoveries that were made by studying salt and fluid homeostasis in weightlessness. These data indicate that 1. atrial natriuretic peptide appears not to play an important role in natriuresis in physiology, 2. the distribution of body fluids appears to be tightly coupled with hunger and thirst regulation, 3. intrathoracic pressure may be an important co-regulator of body fluid homeostasis, 4. a so far unknown low-affinity, high capacity osmotically inactive sodium storage mechanism appears to be present in humans that is acting through sodium/hydrogen exchange on glycosaminoglycans and might explain the pathophysiology, e.g., of salt sensitive hypertension. The surprising and unexpected data underline that weightlessness is an excellent tool to investigate the physiology of our human body: If we knew it, we should be able to predict changes that occur when gravity is absent. But, as data from space demonstrate, we do not.

  20. [Study of work accidents related to human body fluids exposure among health workers at a university hospital].

    PubMed

    Balsamo, Ana Cristina; Felli, Vanda Elisa Andres

    2006-01-01

    This descriptive and exploratory study from a quantitative approach aimed to characterize workers who were victims of work accidents related to human body fluids exposure and to evaluate the accident victim care protocol. The population consisted of 48 workers who were victims of work accidents involving exposure to human body fluids, from July 2000 to June 2001. Data were collected through a form and interviews. Results showed that nursing workers presented higher accident risk levels and that 87.50% involved piercing and cutting material, such as needles and butterflies (70%). As to the accident-related situation/activity, the workers indicated that 25% were due to an "inadequate act during the procedure"; 19.64% mentioned that "it happened" and 29.17% answered that they did not have any suggestion. This study provided important tools to review and elaborate strategies to prevent accidents involving exposure to human body fluids.

  1. Leaks, Lumps, and Lines: Stigma and Women's Bodies

    ERIC Educational Resources Information Center

    Chrisler, Joan C.

    2011-01-01

    Women's bodies have often been positioned in art and popular culture as monstrous or defiled and women's bodily products (e.g., menstrual fluid, breast milk) as disgusting. This framing has led to the stigmatization of aspects of women's bodies (e.g., leaking fluids, lumps of fat, and lines in the skin that indicate aging), especially those…

  2. Brownian microhydrodynamics of active filaments.

    PubMed

    Laskar, Abhrajit; Adhikari, R

    2015-12-21

    Slender bodies capable of spontaneous motion in the absence of external actuation in an otherwise quiescent fluid are common in biological, physical and technological contexts. The interplay between the spontaneous fluid flow, Brownian motion, and the elasticity of the body presents a challenging fluid-structure interaction problem. Here, we model this problem by approximating the slender body as an elastic filament that can impose non-equilibrium velocities or stresses at the fluid-structure interface. We derive equations of motion for such an active filament by enforcing momentum conservation in the fluid-structure interaction and assuming slow viscous flow in the fluid. The fluid-structure interaction is obtained, to any desired degree of accuracy, through the solution of an integral equation. A simplified form of the equations of motion, which allows for efficient numerical solutions, is obtained by applying the Kirkwood-Riseman superposition approximation to the integral equation. We use this form of equation of motion to study dynamical steady states in free and hinged minimally active filaments. Our model provides the foundation to study collective phenomena in momentum-conserving, Brownian, active filament suspensions.

  3. Differentiation of Body Fluid Stains on Fabrics Using External Reflection Fourier Transform Infrared Spectroscopy (FT-IR) and Chemometrics.

    PubMed

    Zapata, Félix; de la Ossa, Ma Ángeles Fernández; García-Ruiz, Carmen

    2016-04-01

    Body fluids are evidence of great forensic interest due to the DNA extracted from them, which allows genetic identification of people. This study focuses on the discrimination among semen, vaginal fluid, and urine stains (main fluids in sexual crimes) placed on different colored cotton fabrics by external reflection Fourier transform infrared spectroscopy (FT-IR) combined with chemometrics. Semen-vaginal fluid mixtures and potential false positive substances commonly found in daily life such as soaps, milk, juices, and lotions were also studied. Results demonstrated that the IR spectral signature obtained for each body fluid allowed its identification and the correct classification of unknown stains by means of principal component analysis (PCA) and soft independent modeling of class analogy (SIMCA). Interestingly, results proved that these IR spectra did not show any bands due to the color of the fabric and no substance of those present in daily life which were analyzed, provided a false positive. © The Author(s) 2016.

  4. Corrosion fatigue behaviors of two biomedical Mg alloys - AZ91D and WE43 - In simulated body fluid.

    PubMed

    Gu, X N; Zhou, W R; Zheng, Y F; Cheng, Y; Wei, S C; Zhong, S P; Xi, T F; Chen, L J

    2010-12-01

    Magnesium alloys have been recently developed as biodegradable implant materials, yet there has been no study concerning their corrosion fatigue properties under cyclic loading. In this study the die-cast AZ91D (A for aluminum 9%, Z for zinc 1% and D for a fourth phase) and extruded WE43 (W for yttrium 4%, E for rare earth mischmetal 3%) alloys were chosen to evaluate their fatigue and corrosion fatigue behaviors in simulated body fluid (SBF). The die-cast AZ91D alloy indicated a fatigue limit of 50MPa at 10⁷ cycles in air compared to 20MPa at 10⁶ cycles tested in SBF at 37°C. A fatigue limit of 110MPa at 10⁷ cycles in air was observed for extruded WE43 alloy compared to 40MPa at 10⁷ cycles tested in SBF at 37°C. The fatigue cracks initiated from the micropores when tested in air and from corrosion pits when tested in SBF, respectively. The overload zone of the extruded WE43 alloy exhibited a ductile fracture mode with deep dimples, in comparison to a brittle fracture mode for the die-cast AZ91D. The corrosion rate of the two experimental alloys increased under cyclic loading compared to that in the static immersion test. Copyright © 2010 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  5. Feasibility of a handheld near infrared device for the qualitative analysis of bloodstains.

    PubMed

    Morillas, Alvaro Varela; Gooch, James; Frascione, Nunzianda

    2018-07-01

    One of the most common tasks in criminal investigation is to determine from which tissue source a biological fluid stain originates. As a result, there are many tests that are frequently used to determine if a stain is blood, semen or saliva by exploiting the properties of certain molecules present within the fluids themselves. These include chemical reagents such as the Kastle-Meyer or Acid Phosphatase tests, as well as other techniques like the use of alternative light sources. However, most of the tests currently available have some major drawbacks. In this study, a handheld near-infrared spectrometer is investigated for the specific identification of deposited bloodstains. First, a calibration was carried out by scanning over 500 positive (blood present) and negative (blood absent) samples to train several predictive models based on machine learning principles. These models were then tested on over 100 new positive and negative samples to evaluate their performance. All models tested were able to correctly classify deposited stains as blood in at least 81% of tested samples, with some models allowing for even higher classification accuracy at over 94%. This suggests that handheld near infrared devices could offer great opportunity for the rapid, low cost and non-destructive screening of body fluids at scenes of crime. Copyright © 2018 Elsevier B.V. All rights reserved.

  6. Vectorcardiographic results from Skylab medical experiment M092: Lower body negative pressure

    NASA Technical Reports Server (NTRS)

    Hoffler, G. W.; Johnson, R. L.; Nicogossian, A. E.; Bergman, S. A., Jr.; Jackson, M. M.

    1974-01-01

    Vectorcardiograms were recorded via a modified Frank lead system from all crewmen of the three Skylab missions in conjuction with the Lower Body Negative Pressure - M092 Experiment. Data were analyzed by a specially developed computer program (VECTAN). Design of the test sequences allowed direct comparisons of supine resting, Earth based (reference) vectorcardiograms with those taken during lower body negative pressure stress and those obtained at rest in orbit, as well as combinations of these conditions. Results revealed several statistically significant space flight related changes; namely, increased testing and lower body negative pressure stressed heart rates, modestly increased PR interval and corrected QTC interval, and greatly increased P and QPS loop maximal amplitudes. In addition, orientation changes in the QRS maximum vector and the J-vector at rest in space seem quite consistent among crewmen and different from those caused by the application of lower body negative pressure. No clinical abnormalities were observed. Etiology of these findings is conjectured to be, at least in part, related to fluid mass shifts occurring in weightlessness and attendant alterations in cardiovascular dynamics and myocardial autonomic control mechanisms.

  7. Detection of malignancy in body fluids: a comparison of the hematology and cytology laboratories.

    PubMed

    Jerz, Jaclyn L; Donohue, Rachel E; Mody, Rayomond R; Schwartz, Mary R; Mody, Dina R; Zieske, Arthur W

    2014-05-01

    Body fluids submitted to the hematology laboratory for cell counts may also be examined for the presence of malignancy. Previous studies evaluating the hematology laboratory's performance at detecting malignancy in body fluids have reached conflicting conclusions. To investigate the hematology laboratory's ability to detect malignancy in body fluids by comparison with cytology. Retrospective analysis of 414 body fluid samples during an 18-month period, with introduction of new quality assurance measures after the first 210 cases. If no concurrent cytology was ordered, results were compared with recent previous and/or subsequent cytologic, histologic, or flow cytometric diagnoses. Of the initial 210 cases, the hematology laboratory detected 3 of 13 malignancies diagnosed by concurrent cytology (23% sensitivity), with no false-positives (100% specificity). Malignancy was not identified on retrospective review of the hematology slides in the 10 discrepant cases. After the initial study, educational sessions on morphology for the medical technologists and a more thorough hematology-cytology correlation policy were implemented. The subsequent 204 hematology laboratory cases had increased sensitivity for the detection of malignancy (60%; 6 of 10). Definitive features of malignancy were seen in only one discrepant hematology laboratory slide on retrospective review. This case had not been flagged for hematopathologist review. None of the discrepancies before or after implementation of the additional quality assurance measures impacted patient care. Body fluid processing by the hematology laboratory is not optimized for the detection of malignancy. Concurrent cytologic examination is critical for the detection of malignancy, and needs to be considered as cost-saving measures are increasingly implemented.

  8. Comparative Assessment of Conventional Papanicolaou and Modified Ultrafast Papanicolaou Stains in Fine Needle Aspiration Samples and Body Fluids.

    PubMed

    Arul, P; Eniya, S; Pushparaj, Magesh; Masilamani, Suresh; Kanmani, P; Lingasamy, C

    2018-01-01

    Conventional Papanicolaou (Pap) stain has undergone many modifications; of these, ultrafast Pap stain is the most popular as it shortens the turnaround time of reporting. Application of modified ultrafast Pap (MUFP) stain in the evaluation of fine needle aspiration (FNA) samples and body fluids are scanty. To evaluate the utility of MUFP stain in various FNA samples and body fluids and compare the findings with those of conventional Pap stain. In this cross-sectional study, two wet-fixed and two airdried smears from each sample [301 samples (255 FNA samples and 46 body fluids)] were prepared and stained by the conventional Pap and MUFP stains, respectively. Concordant and discordant rate was calculated. Quality index (QI) of MUFP stain was assessed by background, overall staining, cell morphology, and nuclear characteristics. MUFP-stained smears were also categorized into excellent, good, and fair. The concordance rate for MUFP stain was 100%. QI of MUFP stain for breast, thyroid, lymph node, soft tissue, salivary gland, and body fluids was 0.9, 0.93, 0.95, 1, 0.94, and 1, respectively. Excellent quality of stain was noted in 53.2% and good in 24.6% of the cases allowing easy diagnosis. In 22.2% of fair cases, diagnosis was possible with some difficulties. Our study concluded that MUFP stain could be considered as a rapid and reliable diagnostic tool and can be applied on a regular basis in FNA samples and body fluids to offer immediate diagnosis. However, caution should be taken while reporting certain MUFP-stained smears to avoid over/under diagnosis.

  9. Ray Solutions to Sound Scattering by Complex Bodies: Application to Zooplankton.

    DTIC Science & Technology

    2000-02-14

    marine snail that swims (elastic shelled body), and (c) siphonophore , a gas- bearing animal (fluid-like tissue containing gas). From Ref. 1...1- LU -100 ^/Vyvv -100 EUPHAUSIID GASTROPOD SIPHONOPHORE 400 500 600 700 800 400 500 600 700 800 FREQUENCY (kHz) FIGURE 2 Target...whose bodies consist of an irregular elastic shell with an opening, and a siphonophore whose body is mostly a fluid-like tissue that contains a

  10. Article, component, and method of forming an article

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lacy, Benjamin Paul; Itzel, Gary Michael; Kottilingam, Srikanth Chandrudu

    An article and method of forming an article are provided. The article includes a body portion separating an inner region and an outer region, an aperture in the body portion, the aperture fluidly connecting the inner region to the outer region, and a conduit extending from an outer surface of the body portion at the aperture and being arranged and disposed to controllably direct fluid from the inner region to the outer region. The method includes providing a body portion separating an inner region and an outer region, providing an aperture in the body portion, and forming a conduit overmore » the aperture, the conduit extending from an outer surface of the body portion and being arranged and disposed to controllably direct fluid from the inner region to the outer region. The article is arranged and disposed for insertion within a hot gas path component.« less

  11. Bioimpedance measurement of body water correlates with measured volume balance in injured patients.

    PubMed

    Rosemurgy, A S; Rodriguez, E; Hart, M B; Kurto, H Z; Albrink, M H

    1993-06-01

    Bioimpedance technology is being used increasingly to determine drug volume of distribution, body water status, and nutrition repletion. Its accuracy in patients experiencing large volume flux is not established. To address this, we undertook this prospective study in 54 consecutive seriously injured adults who had emergency celiotomy soon after arrival in the emergency department. Bioimpedance measurements were obtained in the emergency department before the patient was transported to the operating room, on completion of celiotomy, and 24 hours and 48 hours after celiotomy. Bioimpedance measurements of body water were compared with measured fluid balance. If insensible losses are subtracted from measured fluid balance, the percentage of body weight, which is body water determined by bioimpedance, closely follows fluid flux. This study supports the use of bioimpedance measurements in determining total body water even during periods of surgery, blood loss, and vigorous resuscitation.

  12. Fluid and Electrolyte Balance model (FEB)

    NASA Technical Reports Server (NTRS)

    Fitzjerrell, D. G.

    1973-01-01

    The effects of various oral input water loads on solute and water distribution throughout the body are presented in the form of a model. The model was a three compartment model; the three compartments being plasma, interstitial fluid and cellular fluid. Sodium, potassium, chloride and urea were the only major solutes considered explicitly. The control of body water and electrolyte distribution was affected via drinking and hormone levels.

  13. How you get HIV/AIDS

    MedlinePlus

    How you get HIV/AIDS Which body fluids contain HIV? HIV is a virus that lives in blood and other fluids in the body. Moving ... answers to any questions you have about HIV/AIDS. Your public health department and health care provider ...

  14. [Correction of hydrodynamic disorders in severe alcohol poisoning in adolescent].

    PubMed

    Simakov, A A; Ostreĭkov, I F; Sukhodolova, G N; Dolginov, D M

    2014-01-01

    To improve the results of treatment of children with severe alcohol poisoning as a result of investigation of water sectors of the body. The study included 54 patients aged from 13 to 15 years with a diagnosis of acute severe alcohol poisoning. All patients were divided into three groups. At the initial examination was determined the concentration of alcohol in saliva using Express-test "Alkoskan." Bioimpedance analysis was performed; water sectors of the body were investigated by analyzer of the balance of water sectors ABC-01 "Medass." The study was conducted at the time of admission, after 12, 24 and 48 hours. In severe alcohol poisoning at the time of admission, it was revealed a reduction of the fluid in all studied sectors. The most effective compensation of liquid was observed in groups, where was used combination therapy included intravenous fluids based 4.0 ml/kg/hour. The treatment of severe alcohol poisoning should include fluid resuscitation about 4 ml/kg/hour. This capacity of medical care give the ability to correct adequately the water-sectoral disturbances already in the first 12 hours of hospitalization, and the inclusion to the basic therapy reamberine can contribute more effective replenishment of water sectors.

  15. Lecture Series "Boundary Layer Theory". Part I - Laminar Flows. Part 1; Laminar Flows

    NASA Technical Reports Server (NTRS)

    Schlichting, H.

    1949-01-01

    In the lecture series starting today author want to give a survey of a field of aerodynamics which has for a number of years been attracting an ever growing interest. The subject is the theory of flows with friction, and, within that field, particularly the theory of friction layers, or boundary layers. A great many considerations of aerodynamics are based on the ideal fluid, that is the frictionless incompressibility and fluid. By neglect of compressibility and friction the extensive mathematical theory of the ideal fluid, (potential theory) has been made possible. Actual liquids and gases satisfy the condition of incomressibility rather well if the velocities are not extremely high or, more accurately, if they are small in comparison with sonic velocity. For air, for instance, the change in volume due to compressibility amounts to about 1 percent for a velocity of 60 meters per second. The hypothesis of absence of friction is not satisfied by any actual fluid; however, it is true that most technically important fluids, for instance air and water, have a very small friction coefficient and therefore behave in many cases almost like the ideal frictionless fluid. Many flow phenomena, in particular most cases of lift, can be treated satisfactorily, - that is, the calculations are in good agreement with the test results, -under the assumption of frictionless fluid. However, the calculations with frictionless flow show a very serious deficiency; namely, the fact, known as d'Alembert's paradox, that in frictionless flow each body has zero drag whereas in actual flow each body experiences a drag of greater or smaller magnitude. For a long time the theory has been unable to bridge this gap between the theory of frictionless flow and the experimental findings about actual flow. The cause of this fundamental discrepancy is the viscosity which is neglected in the theory of ideal fluid; however, in spite of its extraordinary smallness it is decisive for the course of the flow phenomena.

  16. Modular robot

    DOEpatents

    Ferrante, T.A.

    1997-11-11

    A modular robot may comprise a main body having a structure defined by a plurality of stackable modules. The stackable modules may comprise a manifold, a valve module, and a control module. The manifold may comprise a top surface and a bottom surface having a plurality of fluid passages contained therein, at least one of the plurality of fluid passages terminating in a valve port located on the bottom surface of the manifold. The valve module is removably connected to the manifold and selectively fluidically connects the plurality of fluid passages contained in the manifold to a supply of pressurized fluid and to a vent. The control module is removably connected to the valve module and actuates the valve module to selectively control a flow of pressurized fluid through different ones of the plurality of fluid passages in the manifold. The manifold, valve module, and control module are mounted together in a sandwich-like manner and comprise a main body. A plurality of leg assemblies are removably connected to the main body and are removably fluidically connected to the fluid passages in the manifold so that each of the leg assemblies can be selectively actuated by the flow of pressurized fluid in different ones of the plurality of fluid passages in the manifold. 12 figs.

  17. Initial fluid resuscitation following adjusted body weight dosing is associated with improved mortality in obese patients with suspected septic shock.

    PubMed

    Taylor, Stephanie Parks; Karvetski, Colleen H; Templin, Megan A; Heffner, Alan C; Taylor, Brice T

    2018-02-01

    The optimal initial fluid resuscitation strategy for obese patients with septic shock is unknown. We evaluated fluid resuscitation strategies across BMI groups. Retrospective analysis of 4157 patients in a multicenter activation pathway for treatment of septic shock between 2014 and 2016. 1293 (31.3%) patients were obese (BMI≥30). Overall, higher BMI was associated with lower mortality, however this survival advantage was eliminated in adjusted analyses. Patients with higher BMI received significantly less fluid per kilogram at 3h than did patients with lower BMI (p≤0.001). In obese patients, fluid given at 3h mimicked a dosing strategy based on actual body weight (ABW) in 780 (72.2%), adjusted body weight (AdjBW) in 95 (8.8%), and ideal body weight (IBW) in 205 (19.0%). After adjusting for condition- and treatment-related variables, dosing based on AdjBW was associated with improved mortality compared to ABW (OR 0.45; 95% CI [0.19, 1.07]) and IBW (OR 0.29; 95% CI [0.11,0.74]). Using AdjBW to calculate initial fluid resuscitation volume for obese patients with suspected shock may improve outcomes compared to other weight-based dosing strategies. The optimal fluid dosing strategy for obese patients should be a focus of future prospective research. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Biological properties of nanostructured Ti incorporated with Ca, P and Ag by electrochemical method.

    PubMed

    Li, Baoe; Hao, Jingzu; Min, Yang; Xin, Shigang; Guo, Litong; He, Fei; Liang, Chunyong; Wang, Hongshui; Li, Haipeng

    2015-06-01

    TiO2 nanotube arrays were synthesized on Ti surface by anodic oxidation. The elements of Ca and P were simultaneously incorporated during nanotubes growth in SBF electrolyte, and then Ag was introduced to nanotube arrays by cathodic deposition, which endowed the good osseointegration and antibacterial property of Ti. The bioactivity of the Ti surface was evaluated by simulated body fluid soaking test. The biocompatibility was investigated by in vitro cell culture test. And the antibacterial effect against Staphylococcus aureus was examined by the bacterial counting method. The results showed that the incorporation of Ca, P and Ag elements had no significant influence on the formation of nanotube arrays on Ti surface during electrochemical treatment. Compared to the polished or nanotubular Ti surface, TiO2 nanotube arrays incorporated with Ca, P and Ag increased the formation of bone-like apatite in simulated body fluid, enhanced cell adhesion and proliferation, and inhibited the bacterial growth. Based on these results, it can be concluded that the nanostructured Ti incorporated with Ca, P and Ag by electrochemical method has promising applications as implant material. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Whole-body fluid distribution in humans during dehydration and recovery, before and after humid-heat acclimation induced using controlled hyperthermia.

    PubMed

    Patterson, M J; Stocks, J M; Taylor, N A S

    2014-04-01

    This experiment was designed to test the hypothesis that the plasma volume is not selectively defended during exercise- and heat-induced dehydration following humid-heat acclimation. Eight physically active males were heat acclimated (39.8 °C, relative humidity 59.2%) using 17 days of controlled hyperthermia (core temperature: 38.5 °C). Inter-compartmental fluid losses and movements were tracked (radioisotopes and Evans blue dye) during progressive dehydration (cycling) in these same conditions and also during a resting recovery without fluid replacement (28 °C), before (day 1), during (day 8) and after heat acclimation (day 22). On days 8 and 22, there were significant increases in total body water, interstitial fluid and plasma volume (P < 0.05), but the intracellular compartments did not change (P > 0.05). The baseline plasma volume remained expanded throughout: 43.4 [±2.6 (day 1)], 49.1 [±2.4 (day 8); P < 0.05] and 48.9 mL kg(-1) [±3.0 (day 22); P < 0.05]. During progressive dehydration, plasma reductions of 9.0% (±0.9: day 1), 12.4% (±1.6: day 8) and 13.6% (±1.2: day 22) were observed, with day 8 and 22 losses significantly exceeding day 1 (P < 0.05). During recovery, plasma volume restoration commenced, with the intracellular fluid contribution becoming more pronounced as acclimation progressed. It is concluded that the plasma volume was not defended more vigorously following humid-heat acclimation. Indeed, a greater fluid loss may well underlie the mechanisms for enhancing plasma volume recovery when heat acclimation is induced using the controlled-hyperthermia technique. © 2013 Scandinavian Physiological Society. Published by John Wiley & Sons Ltd.

  20. Passenger fluid volumes measured before and after a prolonged commercial jet flight.

    NASA Technical Reports Server (NTRS)

    Johnson, P. C.; Carpentier, W. R.; Driscoll, T. B.; Lapinta, C. K.; Rummel, J. A.; Sawin, C. F.

    1972-01-01

    Interstitial and intracellular fluid volumes were calculated from measured plasma volume, extracellular volume and total body water of six subjects before and after a 24-hour commercial overseas flight. No change occurred in these spaces or in peripheral hematocrit or total serum protein concentration. The subjective feeling of dehydration and the actual swelling of the lower extremities characteristically found among passengers at the end of a long trip of this type seems to represent a shift in body fluids to the dependent portions of the body rather than water retention or a decrease in the intravascular water volume.

  1. Discriminant analysis of Raman spectra for body fluid identification for forensic purposes.

    PubMed

    Sikirzhytski, Vitali; Virkler, Kelly; Lednev, Igor K

    2010-01-01

    Detection and identification of blood, semen and saliva stains, the most common body fluids encountered at a crime scene, are very important aspects of forensic science today. This study targets the development of a nondestructive, confirmatory method for body fluid identification based on Raman spectroscopy coupled with advanced statistical analysis. Dry traces of blood, semen and saliva obtained from multiple donors were probed using a confocal Raman microscope with a 785-nm excitation wavelength under controlled laboratory conditions. Results demonstrated the capability of Raman spectroscopy to identify an unknown substance to be semen, blood or saliva with high confidence.

  2. Free and controlled motion of a body with a moving internal mass through a fluid in the presence of circulation around the body

    NASA Astrophysics Data System (ADS)

    Vetchanin, E. V.; Kilin, A. A.

    2016-01-01

    The free and controlled motion of an arbitrary two-dimensional body with a moving internal mass and constant circulation around the body in an ideal fluid is studied. Bifurcation analysis of the free motion is performed (under the condition of a fixed internal mass). It is shown that the body can be moved to a given point by varying the position of the internal mass. Some problems related to the presence of a nonzero drift of the body with a fixed internal mass are noted.

  3. Body Fluids Monitor

    NASA Technical Reports Server (NTRS)

    Siconolfi, Steven F. (Inventor)

    2000-01-01

    Method and apparatus are described for determining volumes of body fluids in a subject using bioelectrical response spectroscopy. The human body is represented using an electrical circuit. Intra-cellular water is represented by a resistor in series with a capacitor; extra-cellular water is represented by a resistor in series with two parallel inductors. The parallel inductors represent the resistance due to vascular fluids. An alternating, low amperage, multifrequency signal is applied to determine a subject's impedance and resistance. From these data, statistical regression is used to determine a 1% impedance where the subject's impedance changes by no more than 1% over a 25 kHz interval. Circuit component, of the human body circuit are determined based on the 1% impedance. Equations for calculating total body water, extra-cellular water, total blood volume, and plasma volume are developed based on the circuit components.

  4. Bioimpedance measurements of human body composition: critical analysis and outlook.

    PubMed

    Matthie, James R

    2008-03-01

    Bioimpedance spectroscopy represents one of the largest emerging medical device technologies. The method is generally known as impedance spectroscopy and is an inexpensive, yet extremely powerful, analytical technique for studying the electrical properties of materials. Much of what we know about biological cells and tissues comes from use of this technique in vitro. Due to the high impedance of the cell membrane, current flow through the cell is frequency dependent and this allows the fluid volume inside versus outside the body's cells to be determined. The fluid outside the cells is primarily related to fluid volume status while the intracellular fluid also relates to the body's cellular mass. Technical advances have removed much of the method's basic complexities. The first commercial bioimpedance spectroscopy device for in vivo human body composition studies was introduced in 1990. Major strides have been made and the method is now poised to enter mainstream clinical medicine but the field is only in its infancy. This paper attempts to fully describe the current use of impedance in the body composition field.

  5. Smart fast blood counting of trace volumes of body fluids from various mammalian species using a compact custom-built microscope cytometer (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian

    2016-03-01

    Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.

  6. The human secretome atlas initiative: Implications in health and disease conditions

    PubMed Central

    Brown, Kristy J; Seol, Haeri; Pillai, Dinesh K; Sankoorikal, Binu-John; Formolo, Catherine A; Mac, Jenny; Edwards, Nathan J.; Rose, Mary C; Hathout, Yetrib

    2013-01-01

    Proteomic analysis of human body fluids is highly challenging, therefore many researchers are redirecting efforts towards secretome profiling. The goal is to define potential biomarkers and therapeutic targets in the secretome that can be traced back in accessible human body fluids. However, currently there is a lack of secretome profiles of normal human primary cells making it difficult to assess the biological meaning of current findings. In this study we sought to establish secretome profiles of human primary cells obtained from healthy donors with the goal of building a human secretome atlas. Such an atlas can be used as a reference for discovery of potential disease associated biomarkers and eventually novel therapeutic targets. As a preliminary study, secretome profiles were established for six different types of human primary cell cultures and checked for overlaps with the three major human body fluids including plasma, cerebrospinal fluid and urine. About 67% of the 1054 identified proteins in the secretome of these primary cells occurred in at least one body fluid. Furthermore, comparison of the secretome profiles of two human glioblastoma cell lines to this new human secretome atlas enabled unambiguous identification of potential brain tumor biomarkers. These biomarkers can be easily monitored in different body fluids using stable isotope labeled standard proteins. The long term goal of this study is to establish a comprehensive online human secretome atlas for future use as a reference for any disease related secretome study. PMID:23603790

  7. Sidewall tensiometer and method of determining soil moisture potential in below-grade earthen soil

    DOEpatents

    Hubbell, Joel M.; Sisson, James B.

    2001-01-01

    A sidewall tensiometer to in situ determine below-grade soil moisture potential of earthen soil includes, a) a body adapted for insertion into an opening in earthen soil below grade, the body having lateral sidewalls; b) a laterally oriented porous material provided relative to the body lateral sidewalls, the laterally oriented porous material at least in part defining a fluid chamber within the body; c) a pressure a sensor in fluid communication with the fluid chamber; and d) sidewall engaging means for engaging a portion of a sidewall of an earth opening to laterally urge the porous material into hydraulic communication with earthen soil of another portion of the opening sidewall. Methods of taking tensiometric measurements are also disclosed.

  8. The development of technology for detection of marijuana intoxication by analysis of body fluids

    DOT National Transportation Integrated Search

    1975-09-01

    A method employing high pressure liquid chromatography plus mass spectrometry was developed for the detection of low concentrations of various marijuana metabolites in body fluids. A new marijuana metabolite was found which could be detected in blood...

  9. Testing single extraction methods and in vitro tests to assess the geochemical reactivity and human bioaccessibility of silver in urban soils amended with silver nanoparticles.

    PubMed

    Cruz, N; Rodrigues, S M; Tavares, D; Monteiro, R J R; Carvalho, L; Trindade, T; Duarte, A C; Pereira, E; Römkens, Paul F A M

    2015-09-01

    To assess if the geochemical reactivity and human bioaccessibility of silver nanoparticles (AgNPs) in soils can be determined by routine soil tests commonly applied to other metals in soil, colloidal Ag was introduced to five pots containing urban soils (equivalent to 6.8 mg Ag kg(-1) soil). Following a 45 days stabilization period, the geochemical reactivity was determined by extraction using 0.43 M and 2 M HNO3. The bioaccessibility of AgNPs was evaluated using the Simplified Bioaccessibility Extraction Test (SBET) the "Unified BARGE Method" (UBM), and two simulated lung fluids (modified Gamble's solution (MGS) and artificial lysosomal fluid (ALF)). The amount of Ag extracted by 0.43 M and 2 M HNO3 soil tests was <8% and <50%, respectively of the total amount of Ag added to soils suggesting that the reactivity of Ag present in the soil can be relatively low. The bioaccessibility of Ag as determined by the four in vitro tests ranged from 17% (ALF extraction) to 99% (SBET) indicating that almost all Ag can be released from soil due to specific interactions with the organic ligands present in the simulated body fluids. This study shows that to develop sound soil risk evaluations regarding soil contamination with AgNPs, aspects of Ag biochemistry need to be considered, particularly when linking commonly applied soil tests to human risk assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Uranium(VI) Binding Forms in Selected Human Body Fluids: Thermodynamic Calculations versus Spectroscopic Measurements.

    PubMed

    Osman, Alfatih A A; Geipel, Gerhard; Barkleit, Astrid; Bernhard, Gert

    2015-02-16

    Human exposure to uranium increasingly becomes a subject of interest in many scientific disciplines such as environmental medicine, toxicology, and radiation protection. Knowledge about uranium chemical binding forms(speciation) in human body fluids can be of great importance to understand not only its biokinetics but also its relevance in risk assessment and in designing decorporation therapy in the case of accidental overexposure. In this study, thermodynamic calculations of uranium speciation in relevant simulated and original body fluids were compared with spectroscopic data after ex-situ uranium addition. For the first time, experimental data on U(VI) speciation in body fluids (saliva, sweat, urine) was obtained by means of cryogenic time-resolved laser-induced fluorescence spectroscopy (cryo-TRLFS) at 153 K. By using the time dependency of fluorescence decay and the band positions of the emission spectra, various uranyl complexes were demonstrated in the studied samples. The variations of the body fluids in terms of chemical composition, pH, and ionic strength resulted in different binding forms of U(VI). The speciation of U(VI) in saliva and in urine was affected by the presence of bioorganic ligands, whereas in sweat, the distribution depends mainly on inorganic ligands. We also elucidated the role of biological buffers, i.e., phosphate (H(2)PO(4−)/HPO(4)(2−)) on U(VI) distribution, and the system Ca(2+)/UO(2)(2+)/PO(4)(3−) was discussed in detail in both saliva and urine. The theoretical speciation calculations of the main U(VI) species in the investigated body fluids were significantly consistent with the spectroscopic data. Laser fluorescence spectroscopy showed success and reliability for direct determination of U(VI) in such biological matrices with the possibility for further improvement.

  11. Comparison of sample preparation techniques and data analysis for the LC-MS/MS-based identification of proteins in human follicular fluid.

    PubMed

    Lehmann, Roland; Schmidt, André; Pastuschek, Jana; Müller, Mario M; Fritzsche, Andreas; Dieterle, Stefan; Greb, Robert R; Markert, Udo R; Slevogt, Hortense

    2018-06-25

    The proteomic analysis of complex body fluids by liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis requires the selection of suitable sample preparation techniques and optimal parameter settings in data analysis software packages to obtain reliable results. Proteomic analysis of follicular fluid, as a representative of a complex body fluid similar to serum or plasma, is difficult as it contains a vast amount of high abundant proteins and a variety of proteins with different concentrations. However, the accessibility of this complex body fluid for LC-MS/MS analysis is an opportunity to gain insights into the status, the composition of fertility-relevant proteins including immunological factors or for the discovery of new diagnostic and prognostic markers for, for example, the treatment of infertility. In this study, we compared different sample preparation methods (FASP, eFASP and in-solution digestion) and three different data analysis software packages (Proteome Discoverer with SEQUEST, Mascot and MaxQuant with Andromeda) combined with semi- and full-tryptic databank search options to obtain a maximum coverage of the follicular fluid proteome. We found that the most comprehensive proteome coverage is achieved by the eFASP sample preparation method using SDS in the initial denaturing step and the SEQUEST-based semi-tryptic data analysis. In conclusion, we have developed a fractionation-free methodical workflow for in depth LC-MS/MS-based analysis for the standardized investigation of human follicle fluid as an important representative of a complex body fluid. Taken together, we were able to identify a total of 1392 proteins in follicular fluid. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Extending the life of mature basins in the North Sea and imaging sub-basalt and sub-intrusive structures using seismic intensity monitoring.

    NASA Astrophysics Data System (ADS)

    De Siena, Luca; Rawlinson, Nicholas

    2016-04-01

    Non-standard seismic imaging (velocity, attenuation, and scattering tomography) of the North Sea basins by using unexploited seismic intensities from previous passive and active surveys are key for better imaging and monitoring fluid under the subsurface. These intensities provide unique solutions to the problem of locating/tracking gas/fluid movements in the crust and depicting sub-basalt and sub-intrusives in volcanic reservoirs. The proposed techniques have been tested in volcanic Islands (Deception Island) and have been proved effective at monitoring fracture opening, imaging buried fluid-filled bodies, and tracking water/gas interfaces. These novel seismic attributes are modelled in space and time and connected with the lithology of the sampled medium, specifically density and permeability with as key output a novel computational code with strong commercial potential.

  13. Physiologic adaptation of man in space; Proceedings of the Seventh International Man in Space Symposium, Houston, TX, Feb. 10-13, 1986

    NASA Technical Reports Server (NTRS)

    Holland, Albert W. (Editor)

    1987-01-01

    Topics discussed in this volume include space motion sickness, cardiovascular adaptation, fluid shifts, extravehicular activity, general physiology, perception, vestibular response modifications, vestibular physiology, and pharmacology. Papers are presented on the clinical characterization and etiology of space motion sickness, ultrasound techniques in space medicine, fluid shifts in weightlessness, Space Shuttle inflight and postflight fluid shifts measured by leg volume changes, and the probability of oxygen toxicity in an 8-psi space suit. Consideration is also given to the metabolic and hormonal status of crewmembers in short-term space flights, adaptive changes in perception of body orientation and mental image rotation in microgravity, the effects of a visual-vestibular stimulus on the vestibulo-ocular reflex, rotation tests in the weightless phase of parabolic flight, and the mechanisms of antimotion sickness drugs.

  14. Energy Balance of Triathletes during an Ultra-Endurance Event

    PubMed Central

    Barrero, Anna; Erola, Pau; Bescós, Raúl

    2014-01-01

    The nutritional strategy during an ultra-endurance triathlon (UET) is one of the main concerns of athletes competing in such events. The purpose of this study is to provide a proper characterization of the energy and fluid intake during real competition in male triathletes during a complete UET and to estimate the energy expenditure (EE) and the fluid balance through the race. Methods: Eleven triathletes performed a UET. All food and drinks ingested during the race were weighed and recorded in order to assess the energy intake (EI) during the race. The EE was estimated from heart rate (HR) recordings during the race, using the individual HR-oxygen uptake (Vo2) regressions developed from three incremental tests on the 50-m swimming pool, cycle ergometer, and running treadmill. Additionally, body mass (BM), total body water (TBW) and intracellular (ICW) and extracellular water (ECW) were assessed before and after the race using a multifrequency bioimpedance device (BIA). Results: Mean competition time and HR was 755 ± 69 min and 137 ± 6 beats/min, respectively. Mean EI was 3643 ± 1219 kcal and the estimated EE was 11,009 ± 664 kcal. Consequently, athletes showed an energy deficit of 7365 ± 1286 kcal (66.9% ± 11.7%). BM decreased significantly after the race and significant losses of TBW were found. Such losses were more related to a reduction of extracellular fluids than intracellular fluids. Conclusions: Our results confirm the high energy demands of UET races, which are not compensated by nutrient and fluid intake, resulting in a large energy deficit. PMID:25558906

  15. Energy balance of triathletes during an ultra-endurance event.

    PubMed

    Barrero, Anna; Erola, Pau; Bescós, Raúl

    2014-12-31

    The nutritional strategy during an ultra-endurance triathlon (UET) is one of the main concerns of athletes competing in such events. The purpose of this study is to provide a proper characterization of the energy and fluid intake during real competition in male triathletes during a complete UET and to estimate the energy expenditure (EE) and the fluid balance through the race. Eleven triathletes performed a UET. All food and drinks ingested during the race were weighed and recorded in order to assess the energy intake (EI) during the race. The EE was estimated from heart rate (HR) recordings during the race, using the individual HR-oxygen uptake (Vo2) regressions developed from three incremental tests on the 50-m swimming pool, cycle ergometer, and running treadmill. Additionally, body mass (BM), total body water (TBW) and intracellular (ICW) and extracellular water (ECW) were assessed before and after the race using a multifrequency bioimpedance device (BIA). Mean competition time and HR was 755 ± 69 min and 137 ± 6 beats/min, respectively. Mean EI was 3643 ± 1219 kcal and the estimated EE was 11,009 ± 664 kcal. Consequently, athletes showed an energy deficit of 7365 ± 1286 kcal (66.9% ± 11.7%). BM decreased significantly after the race and significant losses of TBW were found. Such losses were more related to a reduction of extracellular fluids than intracellular fluids. Our results confirm the high energy demands of UET races, which are not compensated by nutrient and fluid intake, resulting in a large energy deficit.

  16. Effect of drink carbohydrate content on postexercise gastric emptying, rehydration, and the calculation of net fluid balance.

    PubMed

    Clayton, David J; Evans, Gethin H; James, Lewis J

    2014-02-01

    The purpose of this study was to examine the gastric emptying and rehydration effects of hypotonic and hypertonic glucose-electrolyte drinks after exercise-induced dehydration. Eight healthy males lost ~1.8% body mass by intermittent cycling and rehydrated (150% of body mass loss) with a hypotonic 2% (2% trial) or a hypertonic 10% (10% trial) glucose-electrolyte drink over 60 min. Blood and urine samples were taken at preexercise, postexercise, and 60, 120, 180, and 240 min postexercise. Gastric and test drink volume were determined 15, 30, 45, 60, 90, and 120 min postexercise. At the end of the gastric sampling period 0.3% (2% trial) and 42.1% (10% trial; p < .001) of the drinks remained in the stomach. Plasma volume was lower (p < .01) and serum osmolality was greater (p < .001) at 60 and 120 min during the 10% trial. At 240 min, 52% (2% trial) and 64% (10% trial; p < .001) of the drinks were retained. Net fluid balance was greater from 120 min during the 10% trial (p < .001). When net fluid balance was corrected for the volume of fluid in the stomach, it was greater at 60 and 120 min during the 2% trial (p < .001). These results suggest that the reduced urine output following ingestion of a hypertonic rehydration drink might be mediated by a slower rate of gastric emptying, but the slow gastric emptying of such solutions makes rehydration efficiency difficult to determine in the hours immediately after drinking, compromising the calculation of net fluid balance.

  17. The Motion and Control of a Chaplygin Sleigh with Internal Shape in an Ideal Fluid

    NASA Astrophysics Data System (ADS)

    Barot, Christopher

    In this dissertation we will examine a nonholonomic system with Lie group symmetry: the Chaplygin sleigh coupled to an oscillator moving through a potential fluid in two dimensions. This example is chosen to illustrate several general features. The sleigh system in the plane has SE(2) symmetry. This group symmetry will be used to separate the dynamics of the system into those along the group directions and those not. The oscillator motion is not along the group and so acts as an additional configuration space coordinate that plays the role of internal "shape". The potential fluid serves as an interactive environment for the sleigh. The interaction between the fluid and sleigh depends not only on the sleigh body shape and size but also on its motion. The motion of the sleigh causes motion in the surrounding fluid and vice-versa. Since the sleigh body is coupled to the oscillator, the oscillator will have indirect interaction with the fluid. This oscillator serves as internal shape and interacts with the external environment of the sleigh through its coupling to the sleigh body and the nonholonomic constraint; it will be shown that this interaction can produce a variety of types of motion depending on the sleigh geometry. In particular, when the internal shape of the system is actively controlled, it will be proven that the sleigh can be steered through the plane towards any desired position. In this way the sleigh-fluid-oscillator system will demonstrate how a rigid body can be steered through an interactive environment by controlling things wholly within the body itself and without use of external thrust.

  18. Voluntary fluid intake and core temperature responses in adolescent tennis players: sports beverage versus water.

    PubMed

    Bergeron, M F; Waller, J L; Marinik, E L

    2006-05-01

    To examine differences in ad libitum fluid intake, comparing a 6% carbohydrate/electrolyte drink (CHO-E) and water, and associated differences in core temperature and other selected physiological and perceptual responses in adolescent athletes during tennis training in the heat. Fourteen healthy, fit, young tennis players (nine male; five female; mean (SD) age 15.1 (1.4) years; weight 60.6 (8.3) kg; height 172.8 (8.6) cm) completed two 120 minute tennis specific training sessions on separate days (randomised, crossover design) in a warm environment (wet bulb globe temperature: CHO-E, 79.3 (2.6) degrees F; water, 79.9 (2.2) degrees F; p>0.05). There were no significant differences (p>0.05) between the trials with respect to fluid intake, urine volume, fluid retention, sweat loss, perceived exertion, thirst, or gastrointestinal discomfort. However, there was a difference (p<0.05) in the percentage body weight change after training (CHO-E, -0.5 (0.7)%; water, -0.9 (0.6)%). Urine specific gravity before training (CHO-E, 1.024 (0.006); water, 1.025 (0.005)) did not correlate significantly (p>0.05) with any of these measurements or with core body temperature. In examining the main effect for trial, the CHO-E trial showed a significantly lower (p<0.001) mean body temperature (irrespective of measurement time) than the water trial. However, the mean body temperature in each trial was not associated (p>0.05) with fluid intake, fluid retention, sweat loss, or percentage body weight change. Ad libitum consumption of a CHO-E drink may be more effective than water in minimising fluid deficits and mean core temperature responses during tennis and other similar training in adolescent athletes.

  19. Heat shock protein-containing exosomes in mid-trimester amniotic fluids.

    PubMed

    Asea, Alexzander; Jean-Pierre, Claudel; Kaur, Punit; Rao, Preethi; Linhares, Iara M; Skupski, Daniel; Witkin, Steven S

    2008-10-01

    Exosomes are multivesicular bodies formed by inverse membrane budding into the lumen of an endocytic compartment. Fusion with the plasma membrane leads to their release into the external milieu. The incorporation of heat shock proteins into exosomes has been associated with immune regulatory activity. We have examined whether heat shock protein-containing exosomes are present in mid-trimester amniotic fluid. Exosomes were isolated from mid-trimester amniotic fluids by sequential low-speed and high-speed centrifugation followed by sucrose density gradient centrifugation. Biochemical characterization included floatation pattern in sucrose gradients, acetylcholinesterase (AChE) activity and Western blot analysis for exosome-containing proteins. Exosomes were present in each of 23 amniotic fluids tested. They banded at a density of 1.17g/ml in sucrose gradients, were positive for AChE activity and contained tubulin, the inducible 72kDa heat shock protein, Hsp72 and the constitutively expressed heat shock protein, Hsc73; they were negative for calnexin. Exosome concentrations correlated positively with the number of pregnancies. Heat shock protein-containing exosomes are constituents of mid-trimester amniotic fluids and may contribute to immune regulation within the amniotic cavity.

  20. Modelling low Reynolds number vortex-induced vibration problems with a fixed mesh fluid-solid interaction formulation

    NASA Astrophysics Data System (ADS)

    González Cornejo, Felipe A.; Cruchaga, Marcela A.; Celentano, Diego J.

    2017-11-01

    The present work reports a fluid-rigid solid interaction formulation described within the framework of a fixed-mesh technique. The numerical analysis is focussed on the study of a vortex-induced vibration (VIV) of a circular cylinder at low Reynolds number. The proposed numerical scheme encompasses the fluid dynamics computation in an Eulerian domain where the body is embedded using a collection of markers to describe its shape, and the rigid solid's motion is obtained with the well-known Newton's law. The body's velocity is imposed on the fluid domain through a penalty technique on the embedded fluid-solid interface. The fluid tractions acting on the solid are computed from the fluid dynamic solution of the flow around the body. The resulting forces are considered to solve the solid motion. The numerical code is validated by contrasting the obtained results with those reported in the literature using different approaches for simulating the flow past a fixed circular cylinder as a benchmark problem. Moreover, a mesh convergence analysis is also done providing a satisfactory response. In particular, a VIV problem is analyzed, emphasizing the description of the synchronization phenomenon.

  1. Comparison of the antimicrobial adhesion potential of human body fluid glycoconjugates using fucose-binding lectin (PA-IIL) of Pseudomonas aeruginosa and Ulex europaeus lectin (UEA-I).

    PubMed

    Lerrer, Batia; Lesman-Movshovich, Efrat; Gilboa-Garber, Nechama

    2005-09-01

    Pseudomonas aeruginosa produces a fucose-binding lectin (PA-IIL) which strongly binds to human cells. This lectin was shown to be highly sensitive to inhibition by fucose-bearing human milk glycoproteins. Since the glycans of these glycoproteins mimic human cell receptors, they may function as decoys in blocking lectin-dependent pathogen adhesion to the host cells. Human saliva and seminal fluid also contain such compounds, and body fluids of individuals who are "secretors" express additional fucosylated (alpha 1,2) residues. The latter are selectively detected by Ulex europaeus lectin UEA-I. The aim of the present research was to compare the PA-IIL and UEA-I interactions with human salivas and seminal fluids of "secretors" and "nonsecretors" with those obtained with the respective milks. Using hemagglutination inhibition and Western blot analyses, we showed that PA-IIL interactions with the saliva and seminal fluid glycoproteins were somewhat weaker than those obtained with the milk and that "nonsecretor" body fluids were not less efficient than those of "secretors" in PA-IIL blocking. UEA-I, which interacted only with the "secretors" glycoproteins, was most sensitive to those of the seminal fluids.

  2. Numerical Fluid Dynamics.

    DTIC Science & Technology

    1983-01-01

    COROLLARY. Similar bodies held in uniform streams of two incompressible viscous fluids with the same orientation must have the same drag coefficient at...Prandtl’s concept [A8, p. 59] was that the flow field around a streamlined body "splits up into two regions: 1. Surrounding the surface of the solid body ...them in ’source panels’ on the 6surface of the body . As in the two -dimensional case, it may be convenient to assume the solid to be at rest, and immersed

  3. Cerebrospinal fluid culture

    MedlinePlus

    ... Alternative Names Culture - CSF; Spinal fluid culture; CSF culture Images Pneumococci organism References Karcher DS, McPherson RA. Cerebrospinal, synovial, serous body fluids, and alternative specimens. In: McPherson RA, Pincus ...

  4. Unmasking a sustained negative effect of SGLT2 inhibition on body fluid volume in the rat.

    PubMed

    Masuda, Takahiro; Watanabe, Yuko; Fukuda, Keiko; Watanabe, Minami; Onishi, Akira; Ohara, Ken; Imai, Toshimi; Koepsell, Hermann; Muto, Shigeaki; Vallon, Volker; Nagata, Daisuke

    2018-05-23

    The chronic intrinsic diuretic and natriuretic tone of sodium-glucose cotransporter 2 (SGLT2) inhibitors is incompletely understood, because their effect on body fluid volume (BFV) has not been fully evaluated and because they often increase food and fluid intake at the same time. Here we first compared the effect of the SGLT2 inhibitor ipragliflozin (Ipra, 0.01% in diet for 8 weeks) and vehicle (Veh) in Spontaneously Diabetic Torii rat, a non-obese type 2 diabetic model, and non-diabetic Sprague-Dawley rats. In non-diabetic rats, Ipra increased urinary excretion of Na+ (UNaV) and fluid (UV) associated with increased food and fluid intake. Diabetes increased these 4 parameters, but Ipra had no further effect; probably due to its antihyperglycemic effect, such that glucosuria and as a consequence food and fluid intake were unchanged. Fluid balance and BFV, determined by bioimpedance spectroscopy, were similar among the 4 groups. To study the impact of food and fluid intake, non-diabetic rats were treated for 7 days with Veh, Ipra or Ipra+pair-feeding+pair-drinking (Pair-Ipra). Pair-Ipra maintained a small increase in UV and UNaV versus Veh despite similar food and fluid intake. Pair-Ipra induced a negative fluid balance and decreased BFV, while Ipra or Veh had no significant effect compared with basal values. In conclusion, SGLT2 inhibition induces a sustained diuretic and natriuretic tone. Homeostatic mechanisms are activated to stabilize body fluid volume, including compensatory increases in fluid and food intake.

  5. 21 CFR 862.2730 - Osmometer for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862... to measure the osmotic pressure of body fluids. Osmotic pressure is the pressure required to prevent... device are used in the diagnosis and treatment of body fluid disorders. (b) Classification. Class I...

  6. 21 CFR 862.2730 - Osmometer for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862... to measure the osmotic pressure of body fluids. Osmotic pressure is the pressure required to prevent... device are used in the diagnosis and treatment of body fluid disorders. (b) Classification. Class I...

  7. 21 CFR 862.2730 - Osmometer for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862... to measure the osmotic pressure of body fluids. Osmotic pressure is the pressure required to prevent... device are used in the diagnosis and treatment of body fluid disorders. (b) Classification. Class I...

  8. 21 CFR 862.2730 - Osmometer for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) MEDICAL DEVICES CLINICAL CHEMISTRY AND CLINICAL TOXICOLOGY DEVICES Clinical Laboratory Instruments § 862... to measure the osmotic pressure of body fluids. Osmotic pressure is the pressure required to prevent... device are used in the diagnosis and treatment of body fluid disorders. (b) Classification. Class I...

  9. A DFFD simulation method combined with the spectral element method for solid-fluid-interaction problems

    NASA Astrophysics Data System (ADS)

    Chen, Li-Chieh; Huang, Mei-Jiau

    2017-02-01

    A 2D simulation method for a rigid body moving in an incompressible viscous fluid is proposed. It combines one of the immersed-boundary methods, the DFFD (direct forcing fictitious domain) method with the spectral element method; the former is employed for efficiently capturing the two-way FSI (fluid-structure interaction) and the geometric flexibility of the latter is utilized for any possibly co-existing stationary and complicated solid or flow boundary. A pseudo body force is imposed within the solid domain to enforce the rigid body motion and a Lagrangian mesh composed of triangular elements is employed for tracing the rigid body. In particular, a so called sub-cell scheme is proposed to smooth the discontinuity at the fluid-solid interface and to execute integrations involving Eulerian variables over the moving-solid domain. The accuracy of the proposed method is verified through an observed agreement of the simulation results of some typical flows with analytical solutions or existing literatures.

  10. Asbestos bodies in bronchoalveolar lavage fluid. A study of 20 asbestos-exposed individuals and comparison to patients with other chronic interstitial lung diseases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roggli, V.L.; Piantadosi, C.A.; Bell, D.Y.

    1986-09-01

    We studied the asbestos body (AB) content of bronchoalveolar lavage fluid from 20 patients with a history of occupational asbestos exposure, 31 patients with sarcoidosis and 5 patients with idiopathic pulmonary fibrosis. The cellular lavage pellet was digested in sodium hypochlorite and filtered onto Nuclepore filters for AB quantification by light microscopy. ABs were found in 15 of 20 asbestos-exposed individuals, 9 of 31 sarcoidosis cases and 2 of 5 patients with idiopathic pulmonary fibrosis. There was a statistically significant difference in the number of ABs per million cells recovered or per milliliter of recovered lavage fluid in the asbestos-exposedmore » group as compared to the other categories of chronic interstitial lung disease. The highest levels occurred in patients with asbestosis. Large numbers of asbestos bodies in the lavage fluid (greater than 1 AB/10(6) cells) were indicative of considerable occupational asbestos exposure, whereas occasional bodies were a nonspecific finding.« less

  11. Relationship between bioimpedance-determined body composition and peritoneal transport in peritoneal dialysis.

    PubMed

    da Costa, Bernardo M; Del Peso, Gloria; Bajo, Maria Auxiliadora; Carreño, Gilda; Ferreira, Marta; Ferreira, Carina; Selgas, Rafael

    2017-05-29

    In peritoneal dialysis (PD) patients, body fluid homeostasis is dependent on peritoneal elimination of water and solutes. Patients with less favorable peritoneal transport parameters should be more overhydrated. Despite this, the association between faster transport and overhydration (OH) is weak, and the factors that influence hydration status are still poorly characterized. Modified peritoneal equilibration tests (PET) offer us new parameters that might correlate better with hydration status, like free water transport (FWT). The aim of this study was thus to establish the relationships between new peritoneal transport parameters and body composition parameters estimated by bioimpedance spectroscopy (BIS). Prospective observational study on incident PD patients with a baseline and 1-year follow-up evaluation. 61 patients were included in the baseline evaluation, 19 of whom had a 1-year follow-up evaluation; 67.2% were fluid overloaded. There was a negative correlation between D/P creatinine and FWT (r = -0.598, p = 0.000). The fraction of FWT was negatively correlated with OH (r = -0.302, p = 0.018). Peritoneal protein losses (PPL) were also correlated with OH (r = 0.287, p = 0.028). There were no significant differences in OH according to small-solute transport status or fluid output parameters. After 1 year, we observed a significant worsening of renal function and an improvement in 24-hour ultrafiltration (UF) and hydration status, but we detected no differences in peritoneal transport of water or solutes that could explain these changes. There is a poor relationship between kidney/peritoneal function parameters and body composition parameters. The fraction of FWT and PPL may be underestimated markers of peritoneal health and of its contribution to the hydration status.

  12. Computational fluid dynamics vs. inverse dynamics methods to determine passive drag in two breaststroke glide positions.

    PubMed

    Costa, L; Mantha, V R; Silva, A J; Fernandes, R J; Marinho, D A; Vilas-Boas, J P; Machado, L; Rouboa, A

    2015-07-16

    Computational fluid dynamics (CFD) plays an important role to quantify, understand and "observe" the water movements around the human body and its effects on drag (D). We aimed to investigate the flow effects around the swimmer and to compare the drag and drag coefficient (CD) values obtained from experiments (using cable velocimetry in a swimming pool) with those of CFD simulations for the two ventral gliding positions assumed during the breaststroke underwater cycle (with shoulders flexed and upper limbs extended above the head-GP1; with shoulders in neutral position and upper limbs extended along the trunk-GP2). Six well-trained breaststroke male swimmers (with reasonable homogeneity of body characteristics) participated in the experimental tests; afterwards a 3D swimmer model was created to fit within the limits of the sample body size profile. The standard k-ε turbulent model was used to simulate the fluid flow around the swimmer model. Velocity ranged from 1.30 to 1.70 m/s for GP1 and 1.10 to 1.50 m/s for GP2. Values found for GP1 and GP2 were lower for CFD than experimental ones. Nevertheless, both CFD and experimental drag/drag coefficient values displayed a tendency to jointly increase/decrease with velocity, except for GP2 CD where CFD and experimental values display opposite tendencies. Results suggest that CFD values obtained by single model approaches should be considered with caution due to small body shape and dimension differences to real swimmers. For better accuracy of CFD studies, realistic individual 3D models of swimmers are required, and specific kinematics respected. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Interfacing the Generalized Fluid System Simulation Program with the SINDA/G Thermal Program

    NASA Technical Reports Server (NTRS)

    Schallhorn, Paul; Palmiter, Christopher; Farmer, Jeffery; Lycans, Randall; Tiller, Bruce

    2000-01-01

    A general purpose, one dimensional fluid flow code has been interfaced with the thermal analysis program SINDA/G. The flow code, GFSSP, is capable of analyzing steady state and transient flow in a complex network. The flow code is capable of modeling several physical phenomena including compressibility effects, phase changes, body forces (such as gravity and centrifugal) and mixture thermodynamics for multiple species. The addition of GFSSP to SINDA/G provides a significant improvement in convective heat transfer modeling for SINDA/G. The interface development was conducted in two phases. This paper describes the first (which allows for steady and quasi-steady - unsteady solid, steady fluid - conjugate heat transfer modeling). The second (full transient conjugate heat transfer modeling) phase of the interface development will be addressed in a later paper. Phase 1 development has been benchmarked to an analytical solution with excellent agreement. Additional test cases for each development phase demonstrate desired features of the interface. The results of the benchmark case, three additional test cases and a practical application are presented herein.

  14. Swimming Behavior and Flow Geometry: A Fluid Mechanical Study of the Feeding Currents in Calanoid Copepods

    NASA Astrophysics Data System (ADS)

    Jiang, Houshuo; Meneveau, Charles; Osborn, Thomas R.

    2003-11-01

    Copepods are small crustaceans living in oceans and fresh waters and play an important role in the marine and freshwater food webs. As they are the biggest biomass in the oceans some call them "the insects of the sea". Previous laboratory observations have shown that the fluid mechanical phenomena occurring at copepod body scale are crucial for the survival of copepods. One of the interesting phenomena is that many calanoid copepods display various behaviors to create the feeding currents for the purpose of capturing food particles. We have developed a fluid mechanical model to study the feeding currents. The model is a self-propelled body model in that the Navier-Stokes equations are properly coupled with the dynamic equations for the copepod's body. The model has been solved both analytically using the Stokes approximation with a spherical body shape and numerically using CFD with a realistic body shape.

  15. Fatigue properties on the failure mode of a dental implant in a simulated body environment

    NASA Astrophysics Data System (ADS)

    Kim, Min Gun

    2011-10-01

    This study undertook a fatigue test in a simulated body environment that has reflected the conditions (such as the body fluid conditions, the micro-current of cell membranes, and the chewing force) within a living body. First, the study sought to evaluate the fatigue limit under normal conditions and in a simulated body environment, looking into the governing factors of implant fatigue strength through an observation of the fracture mode. In addition, the crack initiation behavior of a tungsten-carbide-coated abutment screw was examined. The fatigue limit of an implant within the simulated body environment decreased by 19 % compared to the limit noted under normal conditions. Several corrosion pits were observed on the abutment screw after the fatigue test in the simulated body environment. For the model used in this study, the implant fracture was mostly governed by the fatigue failure of the abutment screw; accordingly, the influence by the fixture on the fatigue strength of the implant was noted to be low. For the abutment screw coated with tungsten carbide, several times the normal amount of stress was found to be concentrated on the contact part due to the elastic interaction between the coating material and the base material.

  16. Effect of Intravenous Infusion Solutions on Bioelectrical Impedance Spectroscopy.

    PubMed

    Yap, Jason; Rafii, Mahroukh; Azcue, Maria; Pencharz, Paul

    2017-05-01

    Bioelectrical impedance (BIA) is often used to measure body fluid spaces and thereby body composition. However, in acute animal studies, we found that impedance was driven by the saline content of intravenous (IV) fluids and not by the volume. The aim of the study was to investigate the effect of 3 different fluids acutely administered on the change in impedance, specifically resistance (R). Nine healthy adults participated in 3 treatment (0.9% saline, 5% dextrose, and a mixture of 0.3% saline + 3.3% dextrose) experiments on nonconsecutive days. They all received 1 L of one of the treatments intravenously over a 1-hour period. Repeated BIA measurements were performed prior to IV infusion and then every 5 minutes for the 1-hour infusion period, plus 3 more measurements up to 15 minutes after the completion of the infusion. The change in R in the 0.9% saline infusion experiment was significantly lower than that of the glucose and mixture treatment ( P < .001). Bioelectrical impedance spectroscopy and BIA measure salt rather than the volume changes over the infusion period. Hence, in patients receiving IV fluids, BIA of any kind (single frequency or multifrequency) cannot be used to measure body fluid spaces or body composition.

  17. Towards a smart non-invasive fluid loss measurement system.

    PubMed

    Suryadevara, N K; Mukhopadhyay, S C; Barrack, L

    2015-04-01

    In this article, a smart wireless sensing non-invasive system for estimating the amount of fluid loss, a person experiences while physical activity is presented. The system measures three external body parameters, Heart Rate, Galvanic Skin Response (GSR, or skin conductance), and Skin Temperature. These three parameters are entered into an empirically derived formula along with the user's body mass index, and estimation for the amount of fluid lost is determined. The core benefit of the developed system is the affluence usage in combining with smart home monitoring systems to care elderly people in ambient assisted living environments as well in automobiles to monitor the body parameters of a motorist.

  18. Discriminant Analysis of Raman Spectra for Body Fluid Identification for Forensic Purposes

    PubMed Central

    Sikirzhytski, Vitali; Virkler, Kelly; Lednev, Igor K.

    2010-01-01

    Detection and identification of blood, semen and saliva stains, the most common body fluids encountered at a crime scene, are very important aspects of forensic science today. This study targets the development of a nondestructive, confirmatory method for body fluid identification based on Raman spectroscopy coupled with advanced statistical analysis. Dry traces of blood, semen and saliva obtained from multiple donors were probed using a confocal Raman microscope with a 785-nm excitation wavelength under controlled laboratory conditions. Results demonstrated the capability of Raman spectroscopy to identify an unknown substance to be semen, blood or saliva with high confidence. PMID:22319277

  19. Controllable degradation of medical magnesium by electrodeposited composite films of mussel adhesive protein (Mefp-1) and chitosan.

    PubMed

    Jiang, Ping-Li; Hou, Rui-Qing; Chen, Cheng-Dong; Sun, Lan; Dong, Shi-Gang; Pan, Jin-Shan; Lin, Chang-Jian

    2016-09-15

    To control the degradation rate of medical magnesium in body fluid environment, biocompatible films composed of Mussel Adhesive Protein (Mefp-1) and chitosan were electrodeposited on magnesium surface in cathodic constant current mode. The compositions and structures of the films were characterized by atomic force microscope (AFM), scanning electron microscope (SEM) and infrared reflection absorption spectroscopy (IRAS). And the corrosion protection performance was investigated using electrochemical measurements and immersion tests in simulated body fluid (Hanks' solution). The results revealed that Mefp-1 and chitosan successfully adhered on the magnesium surface and formed a protective film. Compared with either single Mefp-1 or single chitosan film, the composite film of chitosan/Mefp-1/chitosan (CPC (chitosan/Mefp-1/chitosan)) exhibited lower corrosion current density, higher polarization resistance and more homogenous corrosion morphology and thus was able to effectively control the degradation rate of magnesium in simulated body environment. In addition, the active attachment and spreading of MC3T3-E1 cells on the CPC film coated magnesium indicated that the CPC film was significantly able to improve the biocompatibility of the medical magnesium. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. GC-MS and LC-MS analysis of nerve agents in body fluids: intra-laboratory verification test using spiked plasma and urine samples.

    PubMed

    Koller, Marianne; Becker, Christian; Thiermann, Horst; Worek, Franz

    2010-05-15

    The purpose of this study was to check the applicability of different analytical methods for the identification of unknown nerve agents in human body fluids. Plasma and urine samples were spiked with nerve agents (plasma) or with their metabolites (urine) or were left blank. Seven random samples (35% of all samples) were selected for the verification test. Plasma was worked up for unchanged nerve agents and for regenerated nerve agents after fluoride-induced reactivation of nerve agent-inhibited butyrylcholinesterase. Both extracts were analysed by GC-MS. Metabolites were extracted from plasma and urine, respectively, and were analysed by LC-MS. The urinary metabolites and two blank samples could be identified without further measurements, plasma metabolites and blanks were identified in six of seven samples. The analysis of unchanged nerve agent provided five agents/blanks and the sixth agent after further investigation. The determination of the regenerated agents also provided only five clear findings during the first screening because of a rather noisy baseline. Therefore, the sample preparation was extended by a size exclusion step performed before addition of fluoride which visibly reduced baseline noise and thus improved identification of the two missing agents. The test clearly showed that verification should be performed by analysing more than one biomarker to ensure identification of the agent(s). Copyright (c) 2010 Elsevier B.V. All rights reserved.

  1. Investigation of corrosion on SAC 305, SAC 0307 and SAC 0307-0.03 P-0.005 Ni solder paste alloys in simulated body fluid (SBF)

    NASA Astrophysics Data System (ADS)

    Sarveswaran, C.; Salleh, Emee Marina; Jalar, A.; Samsudin, Z.; Ali, M. Yusuf Tura; Ani, F. Che; Othman, N. K.

    2017-05-01

    The electrochemical migration (ECM) behaviour of SAC 305, SAC 0307 and SAC 0307-0.03 P-0.005 Ni has been investigated by using simulated body fluid (SBF) solution. Water drop test (WDT) was performed to compute the mean-time-to-failure (MTTF) of each sample while its electrical behaviour was examined using four-point probe test station. The microstructure of each solder paste alloy was observed using field emission scanning electron microscope (FESEM) with energy dispersive X-ray spectroscopy (EDX) to analyse the elemental composition of the solder alloy. The MTTF result shows that SAC 305 has the fastest time-to-failure (TTF) due to short circuit. The corrosion susceptibility of SAC 305 was higher compared with SAC 0307-0.03P-0.005Ni. This was because of the influence of dopant phosphorus and nickel incorporation in the SAC 0307-0.03 P-0.005 Ni. The four point-probe test station reveals that SAC 305 is a good electric conductor whilst SAC 0307-0.03 P-0.005 Ni is a poor electric conductor. The rate of dendritic growth was influenced by the alloying element of the solder. Therefore, SAC 0307-0.03 P-0.005 Ni have a good corrosion resistance in SBF medium.

  2. Biotechnology: Opportunities to Enhance Army Capabilities

    DTIC Science & Technology

    1989-12-01

    without gene vectors Hand pollination Physical methods for DNA or RNA introduction Artificial insemination Cross-species cell fusion and embryo rescue...antibodies and DNA probes to test blood and anaylyze body fluids for more accurate identification of both suspects and victims. 3 I 6 l Artificial blood for...the Army include: *combat casualty care - wound repair, organ regeneration, nerve cell repair, and artificial blood eprophylaxis - protection from

  3. 21 CFR 866.5240 - Complement components immunological test system.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... 866.5240 Section 866.5240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... complement components C1q, C1r, C1s, C2, C3, C4, C5, C6, C7, C8, and C9, in serum, other body fluids, and tissues. Complement is a group of serum proteins which destroy infectious agents. Measurements of these...

  4. 21 CFR 866.5240 - Complement components immunological test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... 866.5240 Section 866.5240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... complement components C1q, C1r, C1s, C2, C3, C4, C5, C6, C7, C8, and C9, in serum, other body fluids, and tissues. Complement is a group of serum proteins which destroy infectious agents. Measurements of these...

  5. 21 CFR 866.5240 - Complement components immunological test system.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... 866.5240 Section 866.5240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... complement components C1q, C1r, C1s, C2, C3, C4, C5, C6, C7, C8, and C9, in serum, other body fluids, and tissues. Complement is a group of serum proteins which destroy infectious agents. Measurements of these...

  6. 21 CFR 866.5240 - Complement components immunological test system.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... 866.5240 Section 866.5240 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... complement components C1q, C1r, C1s, C2, C3, C4, C5, C6, C7, C8, and C9, in serum, other body fluids, and tissues. Complement is a group of serum proteins which destroy infectious agents. Measurements of these...

  7. Physiology of prolonged bed rest

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.

    1988-01-01

    Bed rest has been a normal procedure used by physicians for centuries in the treatment of injury and disease. Exposure of patients to prolonged bed rest in the horizontal position induces adaptive deconditioning responses. While deconditioning responses are appropriate for patients or test subjects in the horizontal position, they usually result in adverse physiological responses (fainting, muscular weakness) when the patient assume the upright posture. These deconditioning responses result from reduction in hydrostatic pressure within the cardiovascular system, virtual elimination of longitudinal pressure on the long bones, some decrease in total body metabolism, changes in diet, and perhaps psychological impact from the different environment. Almost every system in the body is affected. An early stimulus is the cephalic shift of fluid from the legs which increases atrial pressure and induces compensatory responses for fluid and electrolyte redistribution. Without countermeasures, deterioration in strength and muscle function occurs within 1 wk while increased calcium loss may continue for months. Research should also focus on drug and carbohydrate metabolism.

  8. Vascular uptake of rehydration fluids in hypohydrated men at rest and exercise

    NASA Technical Reports Server (NTRS)

    Greenleaf, J. E.; Geelen, G.; Jackson, C. G. R.; Saumet, J.-L.; Juhos, L. T.; Keil, L. C.; Fegan-Meyer, D.; Dearborn, A.; Hinghofer-Szalkay, H.; Whittam, J. H.

    1992-01-01

    The purpose of this study was to formulate and to evaluate rehydration drinks, which would restore total body water and plasma volume (PV), for astronauts to consume before and during extravehicular activity, a few hours before reentry, and immediately after landing. In the first experiment (rest, sitting), five healthy men (23-41 yr), previously dehydrated for 24 hr., drank six (1a, 2, 4, 5, 6, 7) fluid formulations (one each at weekly intervals) and then sat for 70 min. Pre-test PV were measured with Evans blue dye and changes in PV were calculated with the hematocrit-hemoglobin transformation equation. This rest experiment simulated hypohydrated astronauts preparing for reentry. The second experiment (exercise, supine) followed the same protocol except four healthy men (30-46 yr) worked for 70 min. in the supine position on a cycle ergometer at a mean load of 71+/-1 percent of their peak aerobic work capacity. This exercise experiment simulated conditions for astronauts with reduced total body water engaging in extravehicular activity.

  9. Fast-response underwater TSP investigation of subcritical instabilities of a cylinder in crossflow

    NASA Astrophysics Data System (ADS)

    Capone, Alessandro; Klein, Christian; Di Felice, Fabio; Beifuss, Uwe; Miozzi, Massimo

    2015-10-01

    We investigate the classic cylinder in crossflow case to test the effectiveness of a fast-response underwater temperature-sensitive paint coating (TSP) in providing highly resolved spatial and time observations of the action of a flow over a bluff body surface. The flow is investigated at Reynolds number <190 k, before the onset of the drag-crisis state. The obtained TSP image sequences convey an accurate description of the evolution of the main features in the fluid-cylinder interaction, like the separation line position, the pattern of the large coherent structures acting on the cylinder's surface and the small-scale intermittent streamwise arrays of vortices. Ad hoc data management and features extraction techniques are proposed which allow extraction of quantitative data, such as separation line position and vortex-shedding frequency, and results are compared to the literature. Use of TSP for water applications introduces an interesting point of view about the fluid-body interactions by focusing directly on the effect of the flow on the model surface.

  10. Quickly Removable Valve

    NASA Technical Reports Server (NTRS)

    Robbins, John S.

    1988-01-01

    Unit removed with minimal disturbance. Valve inlet and outlet ports adjacent to each other on same side of valve body. Ports inserted into special manifold on fluid line. Valve body attached to manifold by four bolts or, alternatively, by toggle clamps. Electromechanical actuator moves in direction parallel to fluid line to open and close valve. When necessary to clean valve, removed simply by opening bolts or toggle clamps. No need to move or separate ports of fluid line. Valve useful where disturbance of fluid line detrimental or where fast maintenance essential - in oil and chemical industries, automotive vehicles, aircraft, and powerplants.

  11. Contrasting effects of lower body positive pressure on upper airways resistance and partial pressure of carbon dioxide in men with heart failure and obstructive or central sleep apnea.

    PubMed

    Kasai, Takatoshi; Motwani, Shveta S; Yumino, Dai; Gabriel, Joseph M; Montemurro, Luigi Taranto; Amirthalingam, Vinoban; Floras, John S; Bradley, T Douglas

    2013-03-19

    This study sought to test the effects of rostral fluid displacement from the legs on transpharyngeal resistance (Rph), minute volume of ventilation (Vmin), and partial pressure of carbon dioxide (PCO2) in men with heart failure (HF) and either obstructive (OSA) or central sleep apnea (CSA). Overnight rostral fluid shift relates to severity of OSA and CSA in men with HF. Rostral fluid displacement may facilitate OSA if it shifts into the neck and increases Rph, because pharyngeal obstruction causes OSA. Rostral fluid displacement may also facilitate CSA if it shifts into the lungs and induces reflex augmentation of ventilation and reduces PCO2, because a decrease in PCO2 below the apnea threshold causes CSA. Men with HF were divided into those with mainly OSA (obstructive-dominant, n = 18) and those with mainly CSA (central-dominant, n = 10). While patients were supine, antishock trousers were deflated (control) or inflated for 15 min (lower body positive pressure [LBPP]) in random order. LBPP reduced leg fluid volume and increased neck circumference in both obstructive- and central-dominant groups. However, in contrast to the obstructive-dominant group in whom LBPP induced an increase in Rph, a decrease in Vmin, and an increase in PCO2, in the central-dominant group, LBPP induced a reduction in Rph, an increase in Vmin, and a reduction in PCO2. These findings suggest mechanisms by which rostral fluid shift contributes to the pathogenesis of OSA and CSA in men with HF. Rostral fluid shift could facilitate OSA if it induces pharyngeal obstruction, but could also facilitate CSA if it augments ventilation and lowers PCO2. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  12. Effect of irrigation fluid temperature on body temperature during arthroscopic elbow surgery in dogs.

    PubMed

    Thompson, K R; MacFarlane, P D

    2013-01-01

    This prospective randomised clinical trial evaluated the effect of warmed irrigation fluid on body temperature in anaesthetised dogs undergoing arthroscopic elbow surgery. Nineteen dogs undergoing elbow arthroscopy were included in the study and were randomly allocated to one of two groups. Group RT received irrigation fluid at room temperature (RT) while dogs in group W received warmed (W) irrigation fluid (36°C). A standardised patient management and anaesthetic protocol was used and body temperature was measured at four time points; (T1) pre-anaesthetic examination, (T2) arrival into theatre, (T3) end of surgery and (T4) arrival into recovery. There was no significant difference in body temperature at any time point between the groups. The mean overall decrease in body temperature between pre-anaesthetic examination (T1) and return to the recovery suite (T4) was significant in both groups, with a fall of 1.06±0.58°C (p<0.001) in group RT and 1.53±0.76°C (p<0.001) group W. There was no significant difference between the groups. At the end of surgery (T3) 4/19 (21.1%) of dogs were hypothermic (<37°C). The addition of warmed irrigation fluids to a temperature management protocol in dogs undergoing elbow arthroscopy during general anaesthesia did not lead to decreased temperature losses.

  13. Effect of irrigation fluid temperature on body temperature during arthroscopic elbow surgery in dogs

    PubMed Central

    Thompson, K.R.; MacFarlane, P.D.

    2013-01-01

    This prospective randomised clinical trial evaluated the effect of warmed irrigation fluid on body temperature in anaesthetised dogs undergoing arthroscopic elbow surgery. Nineteen dogs undergoing elbow arthroscopy were included in the study and were randomly allocated to one of two groups. Group RT received irrigation fluid at room temperature (RT) while dogs in group W received warmed (W) irrigation fluid (36°C). A standardised patient management and anaesthetic protocol was used and body temperature was measured at four time points; (T1) pre-anaesthetic examination, (T2) arrival into theatre, (T3) end of surgery and (T4) arrival into recovery. There was no significant difference in body temperature at any time point between the groups. The mean overall decrease in body temperature between pre-anaesthetic examination (T1) and return to the recovery suite (T4) was significant in both groups, with a fall of 1.06±0.58°C (p<0.001) in group RT and 1.53±0.76°C (p<0.001) group W. There was no significant difference between the groups. At the end of surgery (T3) 4/19 (21.1%) of dogs were hypothermic (<37°C). The addition of warmed irrigation fluids to a temperature management protocol in dogs undergoing elbow arthroscopy during general anaesthesia did not lead to decreased temperature losses. PMID:26623323

  14. Body fluid regulation in micro-gravity differs from that on Earth: an overview.

    PubMed

    Drummer, C; Gerzer, R; Baisch, F; Heer, M

    2000-01-01

    Similar to the response to central hypervolemic conditions on Earth, the shift of blood volume from the legs to the upper part of the body in astronauts entering micro-gravity should, in accordance with the Henry-Gauer mechanism, mediate diuresis and natriuresis. However, fluid balance and kidney function experiments during various space missions resulted in the surprising observation that the responses qualitatively differ from those observed during simulations of hypervolemia on Earth. There is some evidence that the attenuated responses of the kidney while entering weightlessness, and also later during space flight, may be caused by augmented fluid distribution to extravascular compartments compared to conditions on Earth. A functional decoupling of the kidney may also contribute to the observation that renal responses during exposure to micro-gravity are consistently weaker than those during simulation experiments before space flight. Deficits in body mass after landing have always been interpreted as an indication of absolute fluid loss early during space missions. However, recent data suggest that body mass changes during space flight are rather the consequences of hypocaloric nutrition and can be overcome by improved nutrition schemes. Finally, sodium-retaining humoral systems are activated during space flight and may contribute to a new steady-state of metabolic balances with a pronounced increase in body sodium compared to respective conditions on Earth. A revision of the classical "micro-gravity fluid shift" scheme is required.

  15. Body mass index predicts risk for complications from transtemporal cerebellopontine angle surgery.

    PubMed

    Mantravadi, Avinash V; Leonetti, John P; Burgette, Ryan; Pontikis, George; Marzo, Sam J; Anderson, Douglas

    2013-03-01

    To determine the relationship between body mass index (BMI) and risk for specific complications from transtemporal cerebellopontine angle (CPA) surgery for nonmalignant disease. Case series with chart review. Tertiary-care academic hospital. Retrospective review of 134 consecutive patients undergoing transtemporal cerebellopontine angle surgery for nonmalignant disease from 2009 to 2011. Data were collected regarding demographics, body mass index, intraoperative details, hospital stay, and complications including cerebrospinal fluid leak, wound complications, and brachial plexopathy. One hundred thirty-four patients were analyzed with a mean preoperative body mass index of 28.58. Statistical analysis demonstrated a significant difference in body mass index between patients with a postoperative cerebrospinal fluid leak and those without (P = .04), as well as a similar significant difference between those experiencing postoperative brachial plexopathy and those with no such complication (P = .03). Logistical regression analysis confirmed that body mass index is significant in predicting both postoperative cerebrospinal fluid leak (P = .004; odds ratio, 1.10) and brachial plexopathy (P = .04; odds ratio, 1.07). Elevated body mass index was not significant in predicting wound complications or increased hospital stay beyond postoperative day 3. Risk of cerebrospinal fluid leak and brachial plexopathy is increased in patients with elevated body mass index undergoing surgery of the cerebellopontine angle. Consideration should be given to preoperative optimization via dietary and lifestyle modifications as well as intraoperative somatosensory evoked potential monitoring of the brachial plexus to decrease these risks.

  16. Effect of Change in Fluid Status Evaluated by Bioimpedance Techniques on Body Composition in Hemodialysis Patients.

    PubMed

    Abbas, Samer R; Thijssen, Stephan; Penne, Erik L; Raimann, Jochen G; Liu, Li; Sipahioglu, Murat H; Seibert, Eric; Wang, Yuedong; Chen, Yuqi; Xiao, Qingqing; Levin, Nathan W; Kotanko, Peter; Zhu, Fansan

    2018-05-01

    This prospective study uses calf bioimpedance spectroscopy (cBIS) to guide the attainment of dry weight (DW cBIS ) in chronic hemodialysis (HD) patients. The primary aim of this study was to evaluate whether body composition is altered when fluid status is reduced to DW cBIS . Target post-HD weight was gradually reduced from baseline (BL) until DW cBIS was achieved. DW cBIS was defined as the presence of both flattening of the curve of extracellular resistance and the attainment calf normalized resistivity in the normal range during the dialysis treatment. Extracellular volume (ECV), intracellular volume, and total body water (TBW) were measured using whole body BIS (Hydra 4200). Fluid overload, lean body mass, and fat mass were calculated according to a body composition model. Seventy-three patients enrolled and 60 completed the study (55 ± 13 years, 49% male). Twenty-eight patients (25% diabetes) achieved DW cBIS , whereas 32 patients (47% diabetes) did not. Number of treatment measurements were 16 ± 10 and 12 ± 13 studies per patient in the DW cBIS and non-DW cBIS groups, respectively. Although significant decreases in body weight and ECV were observed, lean body mass and FM did not differ significantly in both groups from BL to the end of study. ECV, ECV/TBW, and fluid overload were higher in the non-DW cBIS than in the DW cBIS group both at BL and at the end of study. Ratios of intradialytic changes in calf normalized resistivity, ECV, and ECV/TBW to ultrafiltration volume were significantly lower in diabetic than in non-diabetic patients. This study shows that decreasing fluid status by gradual reduction of post-HD weight in both DW cBIS and Non-DW cBIS groups did not affect body composition significantly over a period of about 4 weeks. Copyright © 2017 National Kidney Foundation, Inc. Published by Elsevier Inc. All rights reserved.

  17. Spacelab

    NASA Image and Video Library

    1992-06-01

    The first United States Microgravity Laboratory (USML-1) flew in orbit inside the Spacelab science module for extended periods, providing scientists and researchers greater opportunities for research in materials science, fluid dynamics, biotechnology (crystal growth), and combustion science. In this photograph, Astronaut Bornie Dunbar and Astronaut Larry DeLucas are conducting the Lower Body Negative Pressure (LBNP) experiment, which is to protect the health and safety of the crew and to shorten the time required to readapt to gravity when they return to Earth. When humans go into space, the lack of gravity causes many changes in the body. One change is that fluids normally kept in the lower body by gravity, shift upward to the head and chest. This is why astronauts' faces appear chubby or puffy. The change in fluid volume also affects the heart. The reduced fluid volume means that there is less blood to circulate through the body. Crewmembers may experience reduced blood flow to the brain when returning to Earth. This leads to fainting or near-fainting episodes. With the use of LBNP to simulate the pull of gravity in conjunction with fluids, salt tablets can recondition the cardiovascular system. This treatment, called "soak," is effective up to 24 hours. The LBNP uses a three-layer collapsible cylinder that seals around the crewmember's waist which simulates the effects of gravity and helps pull fluids into the lower body. The data collected will be analyzed to determine physiological changes in the crewmembers and effectiveness of the treatment. The USML-1 was launched aboard the Space Shuttle Orbiter Columbia (STS-50) on June 25, 1992.

  18. STS-50 USML-1, Onboard Photograph

    NASA Technical Reports Server (NTRS)

    1992-01-01

    The first United States Microgravity Laboratory (USML-1) flew in orbit inside the Spacelab science module for extended periods, providing scientists and researchers greater opportunities for research in materials science, fluid dynamics, biotechnology (crystal growth), and combustion science. In this photograph, Astronaut Bornie Dunbar and Astronaut Larry DeLucas are conducting the Lower Body Negative Pressure (LBNP) experiment, which is to protect the health and safety of the crew and to shorten the time required to readapt to gravity when they return to Earth. When humans go into space, the lack of gravity causes many changes in the body. One change is that fluids normally kept in the lower body by gravity, shift upward to the head and chest. This is why astronauts' faces appear chubby or puffy. The change in fluid volume also affects the heart. The reduced fluid volume means that there is less blood to circulate through the body. Crewmembers may experience reduced blood flow to the brain when returning to Earth. This leads to fainting or near-fainting episodes. With the use of LBNP to simulate the pull of gravity in conjunction with fluids, salt tablets can recondition the cardiovascular system. This treatment, called 'soak,' is effective up to 24 hours. The LBNP uses a three-layer collapsible cylinder that seals around the crewmember's waist which simulates the effects of gravity and helps pull fluids into the lower body. The data collected will be analyzed to determine physiological changes in the crewmembers and effectiveness of the treatment. The USML-1 was launched aboard the Space Shuttle Orbiter Columbia (STS-50) on June 25, 1992.

  19. Resistance of Magnesium Alloys to Corrosion Fatigue for Biodegradable Implant Applications: Current Status and Challenges

    PubMed Central

    Raman, R. K. Singh; Harandi, Shervin Eslami

    2017-01-01

    Magnesium (Mg) alloys are attracting increasing interest as the most suitable metallic materials for construction of biodegradable and bio-absorbable temporary implants. However, Mg-alloys can suffer premature and catastrophic fracture under the synergy of cyclic loading and corrosion (i.e., corrosion fatigue (CF)). Though Mg alloys are reported to be susceptible to CF also in the corrosive human body fluid, there are very limited studies on this topic. Furthermore, the in vitro test parameters employed in these investigations have not properly simulated the actual conditions in the human body. This article presents an overview of the findings of available studies on the CF of Mg alloys in pseudo-physiological solutions and the employed testing procedures, as well as identifying the knowledge gap. PMID:29144428

  20. Resistance of Magnesium Alloys to Corrosion Fatigue for Biodegradable Implant Applications: Current Status and Challenges.

    PubMed

    Raman, R K Singh; Harandi, Shervin Eslami

    2017-11-16

    Magnesium (Mg) alloys are attracting increasing interest as the most suitable metallic materials for construction of biodegradable and bio-absorbable temporary implants. However, Mg-alloys can suffer premature and catastrophic fracture under the synergy of cyclic loading and corrosion (i.e., corrosion fatigue (CF)). Though Mg alloys are reported to be susceptible to CF also in the corrosive human body fluid, there are very limited studies on this topic. Furthermore, the in vitro test parameters employed in these investigations have not properly simulated the actual conditions in the human body. This article presents an overview of the findings of available studies on the CF of Mg alloys in pseudo-physiological solutions and the employed testing procedures, as well as identifying the knowledge gap.

Top