Sample records for bone surgical simulation

  1. Multi-material 3D Models for Temporal Bone Surgical Simulation.

    PubMed

    Rose, Austin S; Kimbell, Julia S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Buchman, Craig A

    2015-07-01

    A simulated, multicolor, multi-material temporal bone model can be created using 3-dimensional (3D) printing that will prove both safe and beneficial in training for actual temporal bone surgical cases. As the process of additive manufacturing, or 3D printing, has become more practical and affordable, a number of applications for the technology in the field of Otolaryngology-Head and Neck Surgery have been considered. One area of promise is temporal bone surgical simulation. Three-dimensional representations of human temporal bones were created from temporal bone computed tomography (CT) scans using biomedical image processing software. Multi-material models were then printed and dissected in a temporal bone laboratory by attending and resident otolaryngologists. A 5-point Likert scale was used to grade the models for their anatomical accuracy and suitability as a simulation of cadaveric and operative temporal bone drilling. The models produced for this study demonstrate significant anatomic detail and a likeness to human cadaver specimens for drilling and dissection. Simulated temporal bones created by this process have potential benefit in surgical training, preoperative simulation for challenging otologic cases, and the standardized testing of temporal bone surgical skills. © The Author(s) 2015.

  2. Temporal bone dissection simulator for training pediatric otolaryngology surgeons

    NASA Astrophysics Data System (ADS)

    Tabrizi, Pooneh R.; Sang, Hongqiang; Talari, Hadi F.; Preciado, Diego; Monfaredi, Reza; Reilly, Brian; Arikatla, Sreekanth; Enquobahrie, Andinet; Cleary, Kevin

    2017-03-01

    Cochlear implantation is the standard of care for infants born with severe hearing loss. Current guidelines approve the surgical placement of implants as early as 12 months of age. Implantation at a younger age poses a greater surgical challenge since the underdeveloped mastoid tip, along with thin calvarial bone, creates less room for surgical navigation and can result in increased surgical risk. We have been developing a temporal bone dissection simulator based on actual clinical cases for training otolaryngology fellows in this delicate procedure. The simulator system is based on pre-procedure CT (Computed Tomography) images from pediatric infant cases (<12 months old) at our hospital. The simulator includes: (1) simulation engine to provide the virtual reality of the temporal bone surgery environment, (2) a newly developed haptic interface for holding the surgical drill, (3) an Oculus Rift to provide a microscopic-like view of the temporal bone surgery, and (4) user interface to interact with the simulator through the Oculus Rift and the haptic device. To evaluate the system, we have collected 10 representative CT data sets and segmented the key structures: cochlea, round window, facial nerve, and ossicles. The simulator will present these key structures to the user and warn the user if needed by continuously calculating the distances between the tip of surgical drill and the key structures.

  3. Integration of High-resolution Data for Temporal Bone Surgical Simulations

    PubMed Central

    Wiet, Gregory J.; Stredney, Don; Powell, Kimerly; Hittle, Brad; Kerwin, Thomas

    2016-01-01

    Purpose To report on the state of the art in obtaining high-resolution 3D data of the microanatomy of the temporal bone and to process that data for integration into a surgical simulator. Specifically, we report on our experience in this area and discuss the issues involved to further the field. Data Sources Current temporal bone image acquisition and image processing established in the literature as well as in house methodological development. Review Methods We reviewed the current English literature for the techniques used in computer-based temporal bone simulation systems to obtain and process anatomical data for use within the simulation. Search terms included “temporal bone simulation, surgical simulation, temporal bone.” Articles were chosen and reviewed that directly addressed data acquisition and processing/segmentation and enhancement with emphasis given to computer based systems. We present the results from this review in relationship to our approach. Conclusions High-resolution CT imaging (≤100μm voxel resolution), along with unique image processing and rendering algorithms, and structure specific enhancement are needed for high-level training and assessment using temporal bone surgical simulators. Higher resolution clinical scanning and automated processes that run in efficient time frames are needed before these systems can routinely support pre-surgical planning. Additionally, protocols such as that provided in this manuscript need to be disseminated to increase the number and variety of virtual temporal bones available for training and performance assessment. PMID:26762105

  4. Assessment of skills using a virtual reality temporal bone surgery simulator.

    PubMed

    Linke, R; Leichtle, A; Sheikh, F; Schmidt, C; Frenzel, H; Graefe, H; Wollenberg, B; Meyer, J E

    2013-08-01

    Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear.

  5. Pre-operative simulation of pediatric mastoid surgery with 3D-printed temporal bone models.

    PubMed

    Rose, Austin S; Webster, Caroline E; Harrysson, Ola L A; Formeister, Eric J; Rawal, Rounak B; Iseli, Claire E

    2015-05-01

    As the process of additive manufacturing, or three-dimensional (3D) printing, has become more practical and affordable, a number of applications for the technology in the field of pediatric otolaryngology have been considered. One area of promise is temporal bone surgical simulation. Having previously developed a model for temporal bone surgical training using 3D printing, we sought to produce a patient-specific model for pre-operative simulation in pediatric otologic surgery. Our hypothesis was that the creation and pre-operative dissection of such a model was possible, and would demonstrate potential benefits in cases of abnormal temporal bone anatomy. In the case presented, an 11-year-old boy underwent a planned canal-wall-down (CWD) tympano-mastoidectomy for recurrent cholesteatoma preceded by a pre-operative surgical simulation using 3D-printed models of the temporal bone. The models were based on the child's pre-operative clinical CT scan and printed using multiple materials to simulate both bone and soft tissue structures. To help confirm the models as accurate representations of the child's anatomy, distances between various anatomic landmarks were measured and compared to the temporal bone CT scan and the 3D model. The simulation allowed the surgical team to appreciate the child's unusual temporal bone anatomy as well as any challenges that might arise in the safety of the temporal bone laboratory, prior to actual surgery in the operating room (OR). There was minimal variability, in terms of absolute distance (mm) and relative distance (%), in measurements between anatomic landmarks obtained from the patient intra-operatively, the pre-operative CT scan and the 3D-printed models. Accurate 3D temporal bone models can be rapidly produced based on clinical CT scans for pre-operative simulation of specific challenging otologic cases in children, potentially reducing medical errors and improving patient safety. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. PubMed Central

    LINKE, R.; LEICHTLE, A.; SHEIKH, F.; SCHMIDT, C.; FRENZEL, H.; GRAEFE, H.; WOLLENBERG, B.; MEYER, J.E.

    2013-01-01

    SUMMARY Surgery on the temporal bone is technically challenging due to its complex anatomy. Precise anatomical dissection of the human temporal bone is essential and is fundamental for middle ear surgery. We assessed the possible application of a virtual reality temporal bone surgery simulator to the education of ear surgeons. Seventeen ENT physicians with different levels of surgical training and 20 medical students performed an antrotomy with a computer-based virtual temporal bone surgery simulator. The ease, accuracy and timing of the simulated temporal bone surgery were assessed using the automatic assessment software provided by the simulator device and additionally with a modified Final Product Analysis Scale. Trained ENT surgeons, physicians without temporal bone surgical training and medical students were all able to perform the antrotomy. However, the highly trained ENT surgeons were able to complete the surgery in approximately half the time, with better handling and accuracy as assessed by the significant reduction in injury to important middle ear structures. Trained ENT surgeons achieved significantly higher scores using both dissection analysis methods. Surprisingly, there were no significant differences in the results between medical students and physicians without experience in ear surgery. The virtual temporal bone training system can stratify users of known levels of experience. This system can be used not only to improve the surgical skills of trained ENT surgeons for more successful and injury-free surgeries, but also to train inexperienced physicians/medical students in developing their surgical skills for the ear. PMID:24043916

  7. A temporal bone surgery simulator with real-time feedback for surgical training.

    PubMed

    Wijewickrema, Sudanthi; Ioannou, Ioanna; Zhou, Yun; Piromchai, Patorn; Bailey, James; Kennedy, Gregor; O'Leary, Stephen

    2014-01-01

    Timely feedback on surgical technique is an important aspect of surgical skill training in any learning environment, be it virtual or otherwise. Feedback on technique should be provided in real-time to allow trainees to recognize and amend their errors as they occur. Expert surgeons have typically carried out this task, but they have limited time available to spend with trainees. Virtual reality surgical simulators offer effective, repeatable training at relatively low cost, but their benefits may not be fully realized while they still require the presence of experts to provide feedback. We attempt to overcome this limitation by introducing a real-time feedback system for surgical technique within a temporal bone surgical simulator. Our evaluation study shows that this feedback system performs exceptionally well with respect to accuracy and effectiveness.

  8. Virtual reality simulation training in Otolaryngology.

    PubMed

    Arora, Asit; Lau, Loretta Y M; Awad, Zaid; Darzi, Ara; Singh, Arvind; Tolley, Neil

    2014-01-01

    To conduct a systematic review of the validity data for the virtual reality surgical simulator platforms available in Otolaryngology. Ovid and Embase databases searched July 13, 2013. Four hundred and nine abstracts were independently reviewed by 2 authors. Thirty-six articles which fulfilled the search criteria were retrieved and viewed in full text. These articles were assessed for quantitative data on at least one aspect of face, content, construct or predictive validity. Papers were stratified by simulator, sub-specialty and further classified by the validation method used. There were 21 articles reporting applications for temporal bone surgery (n = 12), endoscopic sinus surgery (n = 6) and myringotomy (n = 3). Four different simulator platforms were validated for temporal bone surgery and two for each of the other surgical applications. Face/content validation represented the most frequent study type (9/21). Construct validation studies performed on temporal bone and endoscopic sinus surgery simulators showed that performance measures reliably discriminated between different experience levels. Simulation training improved cadaver temporal bone dissection skills and operating room performance in sinus surgery. Several simulator platforms particularly in temporal bone surgery and endoscopic sinus surgery are worthy of incorporation into training programmes. Standardised metrics are necessary to guide curriculum development in Otolaryngology. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  9. Virtual reality case-specific rehearsal in temporal bone surgery: a preliminary evaluation.

    PubMed

    Arora, Asit; Swords, Chloe; Khemani, Sam; Awad, Zaid; Darzi, Ara; Singh, Arvind; Tolley, Neil

    2014-01-01

    1. To investigate the feasibility of performing case-specific surgical rehearsal using a virtual reality temporal bone simulator. 2. To identify potential clinical applications in temporal bone surgery. Prospective assessment study. St Mary's Hospital, Imperial College NHS Trust, London UK. Sixteen participants consisting of a trainer and trainee group. Twenty-four cadaver temporal bones were CT-scanned and uploaded onto the Voxelman simulator. Sixteen participants performed a 90-min temporal bone dissection on the generic simulation model followed by 3 dissection tasks on the case simulation and cadaver models. Case rehearsal was assessed for feasibility. Clinical applications and usefulness were evaluated using a 5-point Likert-type scale. The upload process required a semi-automated system. Average time for upload was 20 min. Suboptimal reconstruction occurred in 21% of cases arising when the mastoid process and ossicular chain were not captured (n = 2) or when artefact was generated (n = 3). Case rehearsal rated highly (Likert score >4) for confidence (75%), facilitating planning (75%) and training (94%). Potential clinical applications for case rehearsal include ossicular chain surgery, cochlear implantation and congenital anomalies. Case rehearsal of cholesteatoma surgery is not possible on the current platform due to suboptimal soft tissue representation. The process of uploading CT data onto a virtual reality temporal bone simulator to perform surgical rehearsal is feasible using a semi-automated system. Further clinical evaluation is warranted to assess the benefit of performing patient-specific surgical rehearsal in selected procedures. Copyright © 2013 Surgical Associates Ltd. Published by Elsevier Ltd. All rights reserved.

  10. Planning acetabular fracture reduction using patient-specific multibody simulation of the hip

    NASA Astrophysics Data System (ADS)

    Oliveri, Hadrien; Boudissa, Mehdi; Tonetti, Jerome; Chabanas, Matthieu

    2017-03-01

    Acetabular fractures are a challenge in orthopedic surgery. Computer-aided solutions were proposed to segment bone fragments, simulate the fracture reduction or design the osteosynthesis fixation plates. This paper addresses the simulation part, which is usually carried out by freely moving bone fragments with six degrees of freedom to reproduce the pre-fracture state. Instead we propose a different paradigm, closer to actual surgeon's requirements: to simulate the surgical procedure itself rather than the desired result. A simple, patient-specific, biomechanical multibody model is proposed, integrating the main ligaments and muscles of the hip joint while accounting for contacts between bone fragments. Main surgical tools and actions can be simulated, such as clamps, Schanz screws or traction of the femur. Simulations are computed interactively, which enables clinicians to evaluate different strategies for an optimal surgical planning. Six retrospective cases were studied, with simple and complex fracture patterns. After interactively building the models from preoperative CT, gestures from the surgical reports were reproduced. Results of the simulations could then be compared with postoperative CT data. A qualitative study shows the model behavior is excellent and the simulated reductions fit the observed data. A more quantitative analysis is currently being completed. Two cases are particularly significant, for which the surgical reduction actually failed. Simulations show it was indeed not possible to reduce these fractures with the chosen approach. Had our simulator being used, a better planning may have avoided a second surgery to these patients.

  11. Computer aided planning of orthopaedic surgeries: the definition of generic planning steps for bone removal procedures.

    PubMed

    Putzer, David; Moctezuma, Jose Luis; Nogler, Michael

    2017-11-01

    An increasing number of orthopaedic surgeons are using computer aided planning tools for bone removal applications. The aim of the study was to consolidate a set of generic functions to be used for a 3D computer assisted planning or simulation. A limited subset of 30 surgical procedures was analyzed and verified in 243 surgical procedures of a surgical atlas. Fourteen generic functions to be used in 3D computer assisted planning and simulations were extracted. Our results showed that the average procedure comprises 14 ± 10 (SD) steps with ten different generic planning steps and four generic bone removal steps. In conclusion, the study shows that with a limited number of 14 planning functions it is possible to perform 243 surgical procedures out of Campbell's Operative Orthopedics atlas. The results may be used as a basis for versatile generic intraoperative planning software.

  12. A predictive bone drilling force model for haptic rendering with experimental validation using fresh cadaveric bone.

    PubMed

    Lin, Yanping; Chen, Huajiang; Yu, Dedong; Zhang, Ying; Yuan, Wen

    2017-01-01

    Bone drilling simulators with virtual and haptic feedback provide a safe, cost-effective and repeatable alternative to traditional surgical training methods. To develop such a simulator, accurate haptic rendering based on a force model is required to feedback bone drilling forces based on user input. Current predictive bone drilling force models based on bovine bones with various drilling conditions and parameters are not representative of the bone drilling process in bone surgery. The objective of this study was to provide a bone drilling force model for haptic rendering based on calibration and validation experiments in fresh cadaveric bones with different bone densities. Using a commonly used drill bit geometry (2 mm diameter), feed rates (20-60 mm/min) and spindle speeds (4000-6000 rpm) in orthognathic surgeries, the bone drilling forces of specimens from two groups were measured and the calibration coefficients of the specific normal and frictional pressures were determined. The comparison of the predicted forces and the measured forces from validation experiments with a large range of feed rates and spindle speeds demonstrates that the proposed bone drilling forces can predict the trends and average forces well. The presented bone drilling force model can be used for haptic rendering in surgical simulators.

  13. The effect of fidelity: how expert behavior changes in a virtual reality environment.

    PubMed

    Ioannou, Ioanna; Avery, Alex; Zhou, Yun; Szudek, Jacek; Kennedy, Gregor; O'Leary, Stephen

    2014-09-01

    We compare the behavior of expert surgeons operating on the "gold standard" of simulation-the cadaveric temporal bone-against a high-fidelity virtual reality (VR) simulation. We aim to determine whether expert behavior changes within the virtual environment and to understand how the fidelity of simulation affects users' behavior. Five expert otologists performed cortical mastoidectomy and cochleostomy on a human cadaveric temporal bone and a VR temporal bone simulator. Hand movement and video recordings were used to derive a range of measures, to facilitate an analysis of surgical technique, and to compare expert behavior between the cadaveric and simulator environments. Drilling time was similar across the two environments. Some measures such as total time and burr change count differed predictably due to the ease of switching burrs within the simulator. Surgical strokes were generally longer in distance and duration in VR, but these measures changed proportionally to cadaveric measures across the stages of the procedure. Stroke shape metrics differed, which was attributed to the modeling of burr behavior within the simulator. This will be corrected in future versions. Slight differences in drill interaction between a virtual environment and the real world can have measurable effects on surgical technique, particularly in terms of stroke length, duration, and curvature. It is important to understand these effects when designing and implementing surgical training programs based on VR simulation--and when improving the fidelity of VR simulators to facilitate use of a similar technique in both real and simulated situations. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  14. Reconstruction of a Severely Atrophied Alveolar Ridge by Computer-Aided Gingival Simulation and 3D-Printed Surgical Guide: A Case Report.

    PubMed

    Song, In-Seok; Lee, Mi-Ran; Ryu, Jae-Jun; Lee, Ui-Lyong

    Dental implants positioned in severely atrophied anterior maxillae require esthetic or functional compromises. This case report describes the rehabilitation of a severely atrophied alveolar ridge with a three-dimensional (3D) computer-aided design/computer-aided manufacture (CAD/CAM) surgical guide. A 50-year-old woman had a severely atrophied anterior maxilla with unfavorably positioned dental implants. Functional and esthetic prosthodontic restoration was difficult to achieve. An anterior segmental osteotomy was planned to reposition the dental implants. A 3D surgical guide was designed for precise relocation of the segment. The surgical guide firmly grasped the impression copings of the dental implants, minimizing surgical errors. Three-dimensional gingival simulation was used preoperatively to estimate the appropriate position of the gingiva. Rigid fixation to the surrounding bone allowed immobilization of the implant-bone segment. Satisfactory esthetic and functional outcomes were attained 6 months after surgery. Finally, a severely atrophied alveolar ridge with unfavorably positioned dental implants was recovered with minimal esthetic and functional deterioration using gingival simulation and a 3D CAD/CAM surgical guide.

  15. Evaluation of haptic interfaces for simulation of drill vibration in virtual temporal bone surgery.

    PubMed

    Ghasemloonia, Ahmad; Baxandall, Shalese; Zareinia, Kourosh; Lui, Justin T; Dort, Joseph C; Sutherland, Garnette R; Chan, Sonny

    2016-11-01

    Surgical training is evolving from an observership model towards a new paradigm that includes virtual-reality (VR) simulation. In otolaryngology, temporal bone dissection has become intimately linked with VR simulation as the complexity of anatomy demands a high level of surgeon aptitude and confidence. While an adequate 3D visualization of the surgical site is available in current simulators, the force feedback rendered during haptic interaction does not convey vibrations. This lack of vibration rendering limits the simulation fidelity of a surgical drill such as that used in temporal bone dissection. In order to develop an immersive simulation platform capable of haptic force and vibration feedback, the efficacy of hand controllers for rendering vibration in different drilling circumstances needs to be investigated. In this study, the vibration rendering ability of four different haptic hand controllers were analyzed and compared to find the best commercial haptic hand controller. A test-rig was developed to record vibrations encountered during temporal bone dissection and a software was written to render the recorded signals without adding hardware to the system. An accelerometer mounted on the end-effector of each device recorded the rendered vibration signals. The newly recorded vibration signal was compared with the input signal in both time and frequency domains by coherence and cross correlation analyses to quantitatively measure the fidelity of these devices in terms of rendering vibrotactile drilling feedback in different drilling conditions. This method can be used to assess the vibration rendering ability in VR simulation systems and selection of ideal haptic devices. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Computer-aided surgical planner for a new bone deformity correction device using axis-angle representation.

    PubMed

    Wu, Ying Ying; Plakseychuk, Anton; Shimada, Kenji

    2014-11-01

    Current external fixators for distraction osteogenesis (DO) are unable to correct all types of deformities in the lower limb and are difficult to use because of the lack of a pre-surgical planning system. We propose a DO system that consists of a surgical planner and a new, easy-to-setup unilateral fixator that not only corrects all lower limb deformity, but also generates the contralateral/predefined bone shape. Conventionally, bulky constructs with six or more joints (six degrees of freedom, 6DOF) are needed to correct a 3D deformity. By applying the axis-angle representation, we can achieve that with a compact construct with only two joints (2DOF). The proposed system makes use of computer-aided design software and computational methods to plan and simulate the planned procedure. Results of our stress analysis suggest that the stiffness of our proposed fixator is comparable to that of the Orthofix unilateral external fixator. We tested the surgical system on a model of an adult deformed tibia and the resulting bone trajectory deviates from the target bone trajectory by 1.8mm, which is below our defined threshold error of 2mm. We also extracted the transformation matrix that defines the deformity from the bone model and simulated the planned procedure. Copyright © 2014 IPEM. Published by Elsevier Ltd. All rights reserved.

  17. Differentiating levels of surgical experience on a virtual reality temporal bone simulator.

    PubMed

    Zhao, Yi C; Kennedy, Gregor; Hall, Richard; O'Leary, Stephen

    2010-11-01

    Virtual reality simulation is increasingly being incorporated into surgical training and may have a role in temporal bone surgical education. Here we test whether metrics generated by a virtual reality surgical simulation can differentiate between three levels of experience, namely novices, otolaryngology residents, and experienced qualified surgeons. Cohort study. Royal Victorian Eye and Ear Hospital. Twenty-seven participants were recruited. There were 12 experts, six residents, and nine novices. After orientation, participants were asked to perform a modified radical mastoidectomy on the simulator. Comparisons of time taken, injury to structures, and forces exerted were made between the groups to determine which specific metrics would discriminate experience levels. Experts completed the simulated task in significantly shorter time than the other two groups (experts 22 minutes, residents 36 minutes, and novices 46 minutes; P = 0.001). Novices exerted significantly higher average forces when dissecting close to vital structures compared with experts (0.24 Newton [N] vs 0.13 N, P = 0.002). Novices were also more likely to injure structures such as dura compared to experts (23 injuries vs 3 injuries, P = 0.001). Compared with residents, the experts modulated their force between initial cortex dissection and dissection close to vital structures. Using the combination of these metrics, we were able to correctly classify the participants' level of experience 90 percent of the time. This preliminary study shows that measurements of performance obtained from within a virtual reality simulator can differentiate between levels of users' experience. These results suggest that simulator training may have a role in temporal bone training beyond foundational training. Copyright © 2010 American Academy of Otolaryngology–Head and Neck Surgery Foundation. Published by Mosby, Inc. All rights reserved.

  18. Papercraft temporal bone in the first step of anatomy education.

    PubMed

    Hiraumi, Harukazu; Sato, Hiroaki; Ito, Juichi

    2017-06-01

    (1) To compare temporal bone anatomy comprehension taught to speech therapy students with or without a papercraft model. (2) To explore the effect of papercraft simulation on the understanding of surgical approaches in first-year residents. (1) One-hundred and ten speech therapy students were divided into three classes. The first class was taught with a lecture only. The students in the second class were given a lecture and a papercraft modeling task without instruction. The third class modeled a papercraft with instruction after the lecture. The students were tested on their understanding of temporal bone anatomy. (2) A questionnaire on the understanding of surgical approaches was completed by 10 residents before and after the papercraft modeling. The papercraft models were cut with scissors to simulate surgical approaches. (1) The average scores were 4.4/8 for the first class, 4.3/8 for the second class, and 6.3/8 for the third class. The third class had significantly better results than the other classes (p<0.01, Kruskal-Wallis test). (2) The average scores before and after the papercraft modeling and cutting were 2.6/7 and 4.9/7, respectively. The numerical rating scale score significantly improved (p<0.01, Wilcoxon signed-rank test). The instruction of the anatomy using a papercraft temporal bone model is effective in the first step of learning temporal bone anatomy and surgical approaches. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Cortical bone drilling: An experimental and numerical study.

    PubMed

    Alam, Khurshid; Bahadur, Issam M; Ahmed, Naseer

    2014-12-16

    Bone drilling is a common surgical procedure in orthopedics, dental and neurosurgeries. In conventional bone drilling process, the surgeon exerts a considerable amount of pressure to penetrate the drill into the bone tissue. Controlled penetration of drill in the bone is necessary for safe and efficient drilling. Development of a validated Finite Element (FE) model of cortical bone drilling. Drilling experiments were conducted on bovine cortical bone. The FE model of the bone drilling was based on mechanical properties obtained from literature data and additionally conducted microindentation tests on the cortical bone. The magnitude of stress in bone was found to decrease exponentially away from the lips of the drill in simulations. Feed rate was found to be the main influential factor affecting the force and torque in the numerical simulations and experiments. The drilling thrust force and torque were found to be unaffected by the drilling speed in numerical simulations. Simulated forces and torques were compared with experimental results for similar drilling conditions and were found in good agreement.CONCLUSIONS: FE schemes may be successfully applied to model complex kinematics of bone drilling process.

  20. Virtual reality simulation training of mastoidectomy - studies on novice performance.

    PubMed

    Andersen, Steven Arild Wuyts

    2016-08-01

    Virtual reality (VR) simulation-based training is increasingly used in surgical technical skills training including in temporal bone surgery. The potential of VR simulation in enabling high-quality surgical training is great and VR simulation allows high-stakes and complex procedures such as mastoidectomy to be trained repeatedly, independent of patients and surgical tutors, outside traditional learning environments such as the OR or the temporal bone lab, and with fewer of the constraints of traditional training. This thesis aims to increase the evidence-base of VR simulation training of mastoidectomy and, by studying the final-product performances of novices, investigates the transfer of skills to the current gold-standard training modality of cadaveric dissection, the effect of different practice conditions and simulator-integrated tutoring on performance and retention of skills, and the role of directed, self-regulated learning. Technical skills in mastoidectomy were transferable from the VR simulation environment to cadaveric dissection with significant improvement in performance after directed, self-regulated training in the VR temporal bone simulator. Distributed practice led to a better learning outcome and more consolidated skills than massed practice and also resulted in a more consistent performance after three months of non-practice. Simulator-integrated tutoring accelerated the initial learning curve but also caused over-reliance on tutoring, which resulted in a drop in performance when the simulator-integrated tutor-function was discontinued. The learning curves were highly individual but often plateaued early and at an inadequate level, which related to issues concerning both the procedure and the VR simulator, over-reliance on the tutor function and poor self-assessment skills. Future simulator-integrated automated assessment could potentially resolve some of these issues and provide trainees with both feedback during the procedure and immediate assessment following each procedure. Standard setting by establishing a proficiency level that can be used for mastery learning with deliberate practice could also further sophisticate directed, self-regulated learning in VR simulation-based training. VR simulation-based training should be embedded in a systematic and competency-based training curriculum for high-quality surgical skills training, ultimately leading to improved safety and patient care.

  1. A Novel Temporal Bone Simulation Model Using 3D Printing Techniques.

    PubMed

    Mowry, Sarah E; Jammal, Hachem; Myer, Charles; Solares, Clementino Arturo; Weinberger, Paul

    2015-09-01

    An inexpensive temporal bone model for use in a temporal bone dissection laboratory setting can be made using a commercially available, consumer-grade 3D printer. Several models for a simulated temporal bone have been described but use commercial-grade printers and materials to produce these models. The goal of this project was to produce a plastic simulated temporal bone on an inexpensive 3D printer that recreates the visual and haptic experience associated with drilling a human temporal bone. Images from a high-resolution CT of a normal temporal bone were converted into stereolithography files via commercially available software, with image conversion and print settings adjusted to achieve optimal print quality. The temporal bone model was printed using acrylonitrile butadiene styrene (ABS) plastic filament on a MakerBot 2x 3D printer. Simulated temporal bones were drilled by seven expert temporal bone surgeons, assessing the fidelity of the model as compared with a human cadaveric temporal bone. Using a four-point scale, the simulated bones were assessed for haptic experience and recreation of the temporal bone anatomy. The created model was felt to be an accurate representation of a human temporal bone. All raters felt strongly this would be a good training model for junior residents or to simulate difficult surgical anatomy. Material cost for each model was $1.92. A realistic, inexpensive, and easily reproducible temporal bone model can be created on a consumer-grade desktop 3D printer.

  2. Model-based surgical planning and simulation of cranial base surgery.

    PubMed

    Abe, M; Tabuchi, K; Goto, M; Uchino, A

    1998-11-01

    Plastic skull models of seven individual patients were fabricated by stereolithography from three-dimensional data based on computed tomography bone images. Skull models were utilized for neurosurgical planning and simulation in the seven patients with cranial base lesions that were difficult to remove. Surgical approaches and areas of craniotomy were evaluated using the fabricated skull models. In preoperative simulations, hand-made models of the tumors, major vessels and nerves were placed in the skull models. Step-by-step simulation of surgical procedures was performed using actual surgical tools. The advantages of using skull models to plan and simulate cranial base surgery include a better understanding of anatomic relationships, preoperative evaluation of the proposed procedure, increased understanding by the patient and family, and improved educational experiences for residents and other medical staff. The disadvantages of using skull models include the time and cost of making the models. The skull models provide a more realistic tool that is easier to handle than computer-graphic images. Surgical simulation using models facilitates difficult cranial base surgery and may help reduce surgical complications.

  3. Evaluating the Effect of Virtual Reality Temporal Bone Simulation on Mastoidectomy Performance: A Meta-analysis.

    PubMed

    Lui, Justin T; Hoy, Monica Y

    2017-06-01

    Background The increasing prevalence of virtual reality simulation in temporal bone surgery warrants an investigation to assess training effectiveness. Objectives To determine if temporal bone simulator use improves mastoidectomy performance. Data Sources Ovid Medline, Embase, and PubMed databases were systematically searched per the PRISMA guidelines. Review Methods Inclusion criteria were peer-reviewed publications that utilized quantitative data of mastoidectomy performance following the use of a temporal bone simulator. The search was restricted to human studies published in English. Studies were excluded if they were in non-peer-reviewed format, were descriptive in nature, or failed to provide surgical performance outcomes. Meta-analysis calculations were then performed. Results A meta-analysis based on the random-effects model revealed an improvement in overall mastoidectomy performance following training on the temporal bone simulator. A standardized mean difference of 0.87 (95% CI, 0.38-1.35) was generated in the setting of a heterogeneous study population ( I 2 = 64.3%, P < .006). Conclusion In the context of a diverse population of virtual reality simulation temporal bone surgery studies, meta-analysis calculations demonstrate an improvement in trainee mastoidectomy performance with virtual simulation training.

  4. Three-dimensional model simulation and reconstruction of composite total maxillectomy defects with fibula osteomyocutaneous flap flow-through from radial forearm flap.

    PubMed

    He, Yue; Zhu, Han Guang; Zhang, Zhi Yuan; He, Jie; Sader, Robert

    2009-12-01

    A total maxillectomy always causes composite defects of maxilla, zygomatic bone, orbital floor or rim, and palatal and nasal mucosa lining. This leads to significant functional and cosmetic consequences after ablative surgery. The purpose of this clinical study was to preliminarily 3-dimensionally reconstruct the defect of total maxillectomy with sufficient bone support and soft tissue lining. Three-dimensional model simulation technique and free fibula osteomyocutaneous flap flow-through from radial forearm flap were used to reconstruct a total maxillectomy defect for a 21-year-old female patient. Preoperatively, the 3-dimensional (3D) simulated resin models of skeleton and fibula were used to design the osteotomies and bone segment replacement. At surgery, a 22-cm-length free fibula was divided into 4 segments to make 1 maxilla skeletal framework in the schedule of the preoperative model surgical planning with a radial forearm flap flow-through for the free fibula flap with skin paddle to repair the palatal and nasal region. Free fibula and radial forearm flap were alive, and the patient was satisfied with the results both esthetically and functionally after dental rehabilitation which was carried out 6 months after surgery. This preliminarily clinical study and case demonstrated that: the fibula osteomyocutaneous flap is an ideal donor site in 3D total maxillectomy defect reconstruction, because of its thickness, length, and bone uniformity which makes ideal support for dental rehabilitation; the flow-through forearm radial flap not only serves as the vascular bridge to midface reconstruction, but also provides sufficient soft tissue cover for the intraoral defect; and the 3D model simulation and preoperative surgical planning are effective methods to refine reconstruction surgery, shorten the surgical time, and predict the outcome after operation.

  5. Surgical simulation in orthopaedic skills training.

    PubMed

    Atesok, Kivanc; Mabrey, Jay D; Jazrawi, Laith M; Egol, Kenneth A

    2012-07-01

    Mastering rapidly evolving orthopaedic surgical techniques requires a lengthy period of training. Current work-hour restrictions and cost pressures force trainees to face the challenge of acquiring more complex surgical skills in a shorter amount of time. As a result, alternative methods to improve the surgical skills of orthopaedic trainees outside the operating room have been developed. These methods include hands-on training in a laboratory setting using synthetic bones or cadaver models as well as software tools and computerized simulators that enable trainees to plan and simulate orthopaedic operations in a three-dimensional virtual environment. Laboratory-based training offers potential benefits in the development of basic surgical skills, such as using surgical tools and implants appropriately, achieving competency in procedures that have a steep learning curve, and assessing already acquired skills while minimizing concerns for patient safety, operating room time, and financial constraints. Current evidence supporting the educational advantages of surgical simulation in orthopaedic skills training is limited. Despite this, positive effects on the overall education of orthopaedic residents, and on maintaining the proficiency of practicing orthopaedic surgeons, are anticipated.

  6. A review of cutting mechanics and modeling techniques for biological materials.

    PubMed

    Takabi, Behrouz; Tai, Bruce L

    2017-07-01

    This paper presents a comprehensive survey on the modeling of tissue cutting, including both soft tissue and bone cutting processes. In order to achieve higher accuracy in tissue cutting, as a critical process in surgical operations, the meticulous modeling of such processes is important in particular for surgical tool development and analysis. This review paper is focused on the mechanical concepts and modeling techniques utilized to simulate tissue cutting such as cutting forces and chip morphology. These models are presented in two major categories, namely soft tissue cutting and bone cutting. Fracture toughness is commonly used to describe tissue cutting while Johnson-Cook material model is often adopted for bone cutting in conjunction with finite element analysis (FEA). In each section, the most recent mathematical and computational models are summarized. The differences and similarities among these models, challenges, novel techniques, and recommendations for future work are discussed along with each section. This review is aimed to provide a broad and in-depth vision of the methods suitable for tissue and bone cutting simulations. Copyright © 2017 IPEM. Published by Elsevier Ltd. All rights reserved.

  7. Three-dimensional surgical simulation.

    PubMed

    Cevidanes, Lucia H C; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2010-09-01

    In this article, we discuss the development of methods for computer-aided jaw surgery, which allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3-dimensional surface models from cone-beam computed tomography, dynamic cephalometry, semiautomatic mirroring, interactive cutting of bone, and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intraoperative guidance. The system provides further intraoperative assistance with a computer display showing jaw positions and 3-dimensional positioning guides updated in real time during the surgical procedure. The computer-aided surgery system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training, and assessing the difficulties of the surgical procedures before the surgery. Computer-aided surgery can make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. 2010 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  8. 3D Surgical Simulation

    PubMed Central

    Cevidanes, Lucia; Tucker, Scott; Styner, Martin; Kim, Hyungmin; Chapuis, Jonas; Reyes, Mauricio; Proffit, William; Turvey, Timothy; Jaskolka, Michael

    2009-01-01

    This paper discusses the development of methods for computer-aided jaw surgery. Computer-aided jaw surgery allows us to incorporate the high level of precision necessary for transferring virtual plans into the operating room. We also present a complete computer-aided surgery (CAS) system developed in close collaboration with surgeons. Surgery planning and simulation include construction of 3D surface models from Cone-beam CT (CBCT), dynamic cephalometry, semi-automatic mirroring, interactive cutting of bone and bony segment repositioning. A virtual setup can be used to manufacture positioning splints for intra-operative guidance. The system provides further intra-operative assistance with the help of a computer display showing jaw positions and 3D positioning guides updated in real-time during the surgical procedure. The CAS system aids in dealing with complex cases with benefits for the patient, with surgical practice, and for orthodontic finishing. Advanced software tools for diagnosis and treatment planning allow preparation of detailed operative plans, osteotomy repositioning, bone reconstructions, surgical resident training and assessing the difficulties of the surgical procedures prior to the surgery. CAS has the potential to make the elaboration of the surgical plan a more flexible process, increase the level of detail and accuracy of the plan, yield higher operative precision and control, and enhance documentation of cases. Supported by NIDCR DE017727, and DE018962 PMID:20816308

  9. Three-Dimensional Finite Element Analysis of Stress Distribution and Displacement of the Maxilla Following Surgically Assisted Rapid Maxillary Expansion with Tooth- and Bone-Borne Devices.

    PubMed

    Dalband, Mohsen; Kashani, Jamal; Hashemzehi, Hadi

    2015-04-01

    The aim of this study was to investigate the displacement and stress distribution during surgically assisted rapid maxillary expansion under different surgical conditions with tooth- and bone-borne devices. Three-dimensional (3D) finite element model of a maxilla was constructed and an expansion force of 100 N was applied to the left and right molars and premolars with tooth-borne devices and the left and right of mid-palatal sutures at the first molar level with bone-borne devices. Five computer-aided design (CAD) models were simulated as follows and surgical procedures were used: G1: control group (without surgery); G2: Le Fort I osteotomy; G3: Le Fort I osteotomy and para-median osteotomy; G4: Le Fort I osteotomy and pterygomaxillary separation; and G5: Le Fort I osteotomy, para-median osteotomy, and pterygomaxillary separation. Maxillary displacement showed a gradual increase from G1 to G5 in all three planes of space, indicating that Le Fort I osteotomy combined with para-median osteotomy and pterygomaxillary separation produced the greatest displacement of the maxilla with both bone- and tooth-borne devices. Surgical relief and bone-borne devices resulted in significantly reduced stress on anchored teeth. Combination of Le Fort I and para-median osteotomy with pterygomaxillary separation seems to be an effective procedure for increasing maxillary expansion, and excessive stress side effects are lowered around the anchored teeth with the use of bone-borne devices.

  10. Computer-aided resection and endoprosthesis design for the management of malignant bone tumors around the knee: outcomes of 12 cases.

    PubMed

    Ding, Huan-wen; Yu, Guang-wen; Tu, Qiang; Liu, Bao; Shen, Jian-jian; Wang, Hong; Wang, Ying-jun

    2013-11-22

    To report the outcomes of computer-aided resection and endoprosthesis design for the management of malignant bone tumors around the knee. Computed tomography (CT) and magnetic resonance imaging (MRI) data were input into computer software to produce three-dimensional (3D) models of the tumor extent. Imaging data was then used to create a template for surgical resection, and development of an individualized combined allogeneic bone/endoprosthesis. Surgical simulations were performed prior to the actual surgery. This study included 9 males and 3 females with a mean age of 25.3 years (range, 13 to 40 years). There were 9 tumors in the distal femur and 3 in the proximal tibia. There were no surgical complications. In all cases pathologically confirmed clear surgical margins were obtained. Postoperative radiographs showed the range of tumor resection was in accordance with the preoperative design, and the morphological reconstruction of the bone defect was satisfactory with complete bilateral symmetry. The mean follow-up time was 26.5 months. Two patients died of their disease and the remaining are alive and well without evidence of recurrence. All patients are able to ambulate freely without restrictions. At the last follow-up, the average International Society of Limb Salvage score was 25.8 (range, 18 to 27), and was excellent in 8 cases and good in 4 cases. Computer-aided design and modeling for the surgical management of bone tumors and subsequent limb reconstruction provides accurate tumor removal with the salvage of a maximal amount of unaffected bone and precise endoprosthesis reconstruction.

  11. The role of virtual reality in surgical training in otorhinolaryngology.

    PubMed

    Fried, Marvin P; Uribe, José I; Sadoughi, Babak

    2007-06-01

    This article reviews the rationale, current status and future directions for the development and implementation of virtual reality surgical simulators as training tools. The complexity of modern surgical techniques, which utilize advanced technology, presents a dilemma for surgical training. Hands-on patient experience - the traditional apprenticeship method for teaching operations - may not apply because of the learning curve for skill acquisition and patient safety expectation. The paranasal sinuses and temporal bone have intricate anatomy with a significant amount of vital structures either within the surgical field or in close proximity. The current standard of surgical care in these areas involves the use of endoscopes, cameras and microscopes, requiring additional hand-eye coordination, an accurate command of fine motor skills, and a thorough knowledge of the anatomy under magnified vision. A surgeon's disorientation or loss of perspective can lead to complications, often catastrophic and occasionally lethal. These considerations define the ideal environment for surgical simulation; not surprisingly, significant research and validation of simulators in these areas have occurred. Virtual reality simulators are demonstrating validity as training and skills assessment tools. Future prototypes will find application for routine use in teaching, surgical planning and the development of new instruments and computer-assisted devices.

  12. Skull reconstruction after resection of bone tumors in a single surgical time by the association of the techniques of rapid prototyping and surgical navigation.

    PubMed

    Anchieta, M V M; Salles, F A; Cassaro, B D; Quaresma, M M; Santos, B F O

    2016-10-01

    Presentation of a new cranioplasty technique employing a combination of two technologies: rapid prototyping and surgical navigation. This technique allows the reconstruction of the skull cap after the resection of a bone tumor in a single surgical time. The neurosurgeon plans the craniotomy previously on the EximiusMed software, compatible with the Eximius Surgical Navigator, both from the company Artis Tecnologia (Brazil). The navigator imports the planning and guides the surgeon during the craniotomy. The simulation of the bone fault allows the virtual reconstruction of the skull cap and the production of a personalized modelling mold using the Magics-Materialise (Belgium)-software. The mold and a replica of the bone fault are made by rapid prototyping by the company Artis Tecnologia (Brazil) and shipped under sterile conditions to the surgical center. The PMMA prosthesis is produced during the surgical act with the help of a hand press. The total time necessary for the planning and production of the modelling mold is four days. The precision of the mold is submillimetric and accurately reproduces the virtual reconstruction of the prosthesis. The production of the prosthesis during surgery takes until twenty minutes depending on the type of PMMA used. The modelling mold avoids contraction and dissipates the heat generated by the material's exothermic reaction in the polymerization phase. The craniectomy is performed with precision over the drawing made with the help of the Eximius Surgical Navigator, according to the planned measurements. The replica of the bone fault serves to evaluate the adaptation of the prosthesis as a support for the perforations and the placement of screws and fixation plates, as per the surgeon's discretion. This technique allows the adequate oncologic treatment associated with a satisfactory aesthetic result, with precision, in a single surgical time, reducing time and costs.

  13. Feasibility and fidelity of practising surgical fixation on a virtual ulna bone

    PubMed Central

    LeBlanc, Justin; Hutchison, Carol; Hu, Yaoping; Donnon, Tyrone

    2013-01-01

    Background Surgical simulators provide a safe environment to learn and practise psychomotor skills. A goal for these simulators is to achieve high levels of fidelity. The purpose of this study was to develop a reliable surgical simulator fidelity questionnaire and to assess whether a newly developed virtual haptic simulator for fixation of an ulna has comparable levels of fidelity as Sawbones. Methods Simulator fidelity questionnaires were developed. We performed a stratified randomized study with surgical trainees. They performed fixation of the ulna using a virtual simulator and Sawbones. They completed the fidelity questionnaires after each procedure. Results Twenty-two trainees participated in the study. The reliability of the fidelity questionnaire for each separate domain (environment, equipment, psychological) was Cronbach α greater than 0.70, except for virtual environment. The Sawbones had significantly higher levels of fidelity than the virtual simulator (p < 0.001) with a large effect size difference (Cohen d < 1.3). Conclusion The newly developed fidelity questionnaire is a reliable tool that can potentially be used to determine the fidelity of other surgical simulators. Increasing the fidelity of this virtual simulator is required before its use as a training tool for surgical fixation. The virtual simulator brings with it the added benefits of repeated, independent safe use with immediate, objective feedback and the potential to alter the complexity of the skill. PMID:23883510

  14. In vitro simulation of pathological bone conditions to predict clinical outcome of bone tissue engineered materials

    NASA Astrophysics Data System (ADS)

    Nguyen, Duong Thuy Thi

    According to the Centers for Disease Control, the geriatric population of ≥65 years of age will increase to 51.5 million in 2020; 40% of white women and 13% of white men will be at risk for fragility fractures or fractures sustained under normal stress and loading conditions due to bone disease, leading to hospitalization and surgical treatment. Fracture management strategies can be divided into pharmaceutical therapy, surgical intervention, and tissue regeneration for fracture prevention, fracture stabilization, and fracture site regeneration, respectively. However, these strategies fail to accommodate the pathological nature of fragility fractures, leading to unwanted side effects, implant failures, and non-unions. Compromised innate bone healing reactions of patients with bone diseases are exacerbated with protective bone therapy. Once these patients sustain a fracture, bone healing is a challenge, especially when fracture stabilization is unsuccessful. Traditional stabilizing screw and plate systems were designed with emphasis on bone mechanics rather than biology. Bone grafts are often used with fixation devices to provide skeletal continuity at the fracture gap. Current bone grafts include autologous bone tissue and donor bone tissue; however, the quality and quantity demanded by fragility fractures sustained by high-risk geriatric patients and patients with bone diseases are not met. Consequently, bone tissue engineering strategies are advancing towards functionalized bone substitutes to provide fracture reconstruction while effectively mediating bone healing in normal and diseased fracture environments. In order to target fragility fractures, fracture management strategies should be tailored to allow bone regeneration and fracture stabilization with bioactive bone substitutes designed for the pathological environment. The clinical outcome of these materials must be predictable within various disease environments. Initial development of a targeted treatment strategy should focus on simulating, in vitro, a physiological bone environment to predict clinical effectiveness of engineered bone and understand cellular responses due to the proposed agents and bioactive scaffolds. An in vitro test system can be the necessary catalyst to reduce implant failures and non-unions in fragility fractures.

  15. Orbital Osteoblastoma: Technical Innovations in Resection and Reconstruction Using Virtual Surgery Simulation.

    PubMed

    Novelli, Giorgio; Gramegna, Marco; Tonellini, Gabriele; Valente, Gabriella; Boni, Pietro; Bozzetti, Alberto; Sozzi, Davide

    2016-09-01

    Osteoblastoma is a benign tumor of bone, representing less than 1% of bone tumors. Craniomaxillofacial localizations account for up to 15% of the total and frequently involve the posterior mandible. Endo-orbital localization is very rare, with most occurring in young patients. Very few of these tumors become malignant. Orbital localization requires radical removal of the tumor followed by careful surgical reconstruction of the orbit to avoid subsequent aesthetic or functional problems. Here, we present a clinical case of this condition and describe a surgical protocol that uses and integrates state-of-the art technologies to achieve orbital reconstruction.

  16. Characterization of synthetic foam structures used to manufacture artificial vertebral trabecular bone.

    PubMed

    Fürst, David; Senck, Sascha; Hollensteiner, Marianne; Esterer, Benjamin; Augat, Peter; Eckstein, Felix; Schrempf, Andreas

    2017-07-01

    Artificial materials reflecting the mechanical properties of human bone are essential for valid and reliable implant testing and design. They also are of great benefit for realistic simulation of surgical procedures. The objective of this study was therefore to characterize two groups of self-developed synthetic foam structures by static compressive testing and by microcomputed tomography. Two mineral fillers and varying amounts of a blowing agent were used to create different expansion behavior of the synthetic open-cell foams. The resulting compressive and morphometric properties thus differed within and also slightly between both groups. Apart from the structural anisotropy, the compressive and morphometric properties of the synthetic foam materials were shown to mirror the respective characteristics of human vertebral trabecular bone in good approximation. In conclusion, the artificial materials created can be used to manufacture valid synthetic bones for surgical training. Further, they provide novel possibilities for studying the relationship between trabecular bone microstructure and biomechanical properties. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. [Bone drilling simulation by three-dimensional imaging].

    PubMed

    Suto, Y; Furuhata, K; Kojima, T; Kurokawa, T; Kobayashi, M

    1989-06-01

    The three-dimensional display technique has a wide range of medical applications. Pre-operative planning is one typical application: in orthopedic surgery, three-dimensional image processing has been used very successfully. We have employed this technique in pre-operative planning for orthopedic surgery, and have developed a simulation system for bone-drilling. Positive results were obtained by pre-operative rehearsal; when a region of interest is indicated by means of a mouse on the three-dimensional image displayed on the CRT, the corresponding region appears on the slice image which is displayed simultaneously. Consequently, the status of the bone-drilling is constantly monitored. In developing this system, we have placed emphasis on the quality of the reconstructed three-dimensional images, on fast processing, and on the easy operation of the surgical planning simulation.

  18. Computer-assisted virtual preoperative planning in orthopedic surgery for acetabular fractures based on actual computed tomography data.

    PubMed

    Wang, Guang-Ye; Huang, Wen-Jun; Song, Qi; Qin, Yun-Tian; Liang, Jin-Feng

    2016-12-01

    Acetabular fractures have always been very challenging for orthopedic surgeons; therefore, appropriate preoperative evaluation and planning are particularly important. This study aimed to explore the application methods and clinical value of preoperative computer simulation (PCS) in treating pelvic and acetabular fractures. Spiral computed tomography (CT) was performed on 13 patients with pelvic and acetabular fractures, and Digital Imaging and Communications in Medicine (DICOM) data were then input into Mimics software to reconstruct three-dimensional (3D) models of actual pelvic and acetabular fractures for preoperative simulative reduction and fixation, and to simulate each surgical procedure. The times needed for virtual surgical modeling and reduction and fixation were also recorded. The average fracture-modeling time was 45 min (30-70 min), and the average time for bone reduction and fixation was 28 min (16-45 min). Among the surgical approaches planned for these 13 patients, 12 were finally adopted; 12 cases used the simulated surgical fixation, and only 1 case used a partial planned fixation method. PCS can provide accurate surgical plans and data support for actual surgeries.

  19. Face and content validation of a virtual reality temporal bone simulator.

    PubMed

    Arora, Asit; Khemani, Sam; Tolley, Neil; Singh, Arvind; Budge, James; Varela, David A Diaz Voss; Francis, Howard W; Darzi, Ara; Bhatti, Nasir I

    2012-03-01

    To validate the VOXEL-MAN TempoSurg simulator for temporal bone dissection. Prospective international study. Otolaryngology departments of 2 academic health care institutions in the United Kingdom and United States. Eighty-five subjects were recruited consisting of an experienced and referent group. Participants performed a standardized familiarization session and temporal bone dissection task. Realism, training effectiveness, and global impressions were evaluated across 21 domains using a 5-point Likert-type scale. A score of 4 was the minimum threshold for acceptability. The experienced group comprised 25 otolaryngology trainers who had performed 150 mastoid operations. The referent group comprised 60 trainees (mean otolaryngology experience of 2.9 years). Familiarization took longer in the experienced group (P = .01). User-friendliness was positively rated (mean score 4.1). Seventy percent of participants rated anatomical appearance as acceptable. Trainers rated drill ergonomics worse than did trainees (P = .01). Simulation temporal bone training scored highly (mean score 4.3). Surgical anatomy, drill navigation, and hand-eye coordination accounted for this. Trainees were more likely to recommend temporal bone simulation to a colleague than were trainers (P = .01). Transferability of skills to the operating room was undecided (mean score 3.5). Realism of the VOXEL-MAN virtual reality temporal bone simulator is suboptimal in its current version. Nonetheless, it represents a useful adjunct to existing training methods and is particularly beneficial for novice surgeons before performing cadaveric temporal bone dissection. Improvements in realism, specifically drill ergonomics and visual-spatial perception during deeper temporal bone dissection, are warranted.

  20. Preoperative simulation for the planning of microsurgical clipping of intracranial aneurysms.

    PubMed

    Marinho, Paulo; Vermandel, Maximilien; Bourgeois, Philippe; Lejeune, Jean-Paul; Mordon, Serge; Thines, Laurent

    2014-12-01

    The safety and success of intracranial aneurysm (IA) surgery could be improved through the dedicated application of simulation covering the procedure from the 3-dimensional (3D) description of the surgical scene to the visual representation of the clip application. We aimed in this study to validate the technical feasibility and clinical relevance of such a protocol. All patients preoperatively underwent 3D magnetic resonance imaging and 3D computed tomography angiography to build 3D reconstructions of the brain, cerebral arteries, and surrounding cranial bone. These 3D models were segmented and merged using Osirix, a DICOM image processing application. This provided the surgical scene that was subsequently imported into Blender, a modeling platform for 3D animation. Digitized clips and appliers could then be manipulated in the virtual operative environment, allowing the visual simulation of clipping. This simulation protocol was assessed in a series of 10 IAs by 2 neurosurgeons. The protocol was feasible in all patients. The visual similarity between the surgical scene and the operative view was excellent in 100% of the cases, and the identification of the vascular structures was accurate in 90% of the cases. The neurosurgeons found the simulation helpful for planning the surgical approach (ie, the bone flap, cisternal opening, and arterial tree exposure) in 100% of the cases. The correct number of final clip(s) needed was predicted from the simulation in 90% of the cases. The preoperatively expected characteristics of the optimal clip(s) (ie, their number, shape, size, and orientation) were validated during surgery in 80% of the cases. This study confirmed that visual simulation of IA clipping based on the processing of high-resolution 3D imaging can be effective. This is a new and important step toward the development of a more sophisticated integrated simulation platform dedicated to cerebrovascular surgery.

  1. Virtual temporal bone: an interactive 3-dimensional learning aid for cranial base surgery.

    PubMed

    Kockro, Ralf A; Hwang, Peter Y K

    2009-05-01

    We have developed an interactive virtual model of the temporal bone for the training and teaching of cranial base surgery. The virtual model was based on the tomographic data of the Visible Human Project. The male Visible Human's computed tomographic data were volumetrically reconstructed as virtual bone tissue, and the individual photographic slices provided the basis for segmentation of the middle and inner ear structures, cranial nerves, vessels, and brainstem. These structures were created by using outlining and tube editing tools, allowing structural modeling either directly on the basis of the photographic data or according to information from textbooks and cadaver dissections. For training and teaching, the virtual model was accessed in the previously described 3-dimensional workspaces of the Dextroscope or Dextrobeam (Volume Interactions Pte, Ltd., Singapore), whose interfaces enable volumetric exploration from any perspective and provide virtual tools for drilling and measuring. We have simulated several cranial base procedures including approaches via the floor of the middle fossa and the lateral petrous bone. The virtual model suitably illustrated the core facts of anatomic spatial relationships while simulating different stages of bone drilling along a variety of surgical corridors. The system was used for teaching during training courses to plan and discuss operative anatomy and strategies. The Virtual Temporal Bone and its surrounding 3-dimensional workspace provide an effective way to study the essential surgical anatomy of this complex region and to teach and train operative strategies, especially when used as an adjunct to cadaver dissections.

  2. [3D printing in neurosurgery: a specific model for patients with craniosynostosis].

    PubMed

    Jiménez Ormabera, Borja; Díez Valle, Ricardo; Zaratiegui Fernández, Javier; Llorente Ortega, Marcos; Unamuno Iñurritegui, Xabier; Tejada Solís, Sonia

    Craniosynostosis is a rare condition and requires a personalised surgical approach, which is why we consider the use of 3D printed models beneficial in the surgical planning of this procedure. Acrylonitrile butadiene styrene plastic skull models were designed and printed from CT images of patients between 3 and 6 months of age with craniosynostosis of different sutures. The models were used to simulate surgical procedures. Four models of four patients with craniosynostosis were produced: two with closure of the metopic suture and two with sagittal suture closure. The mean age of the patients was 5 months (3-6m) and the mean duration of the surgery was 286min (127-380min). The acrylonitrile butadiene styrene plastic models printed for the project proved to be optimal for the simulation of craniosynostosis surgeries, both anatomically and in terms of mechanical properties and reaction to surgical instruments. 3D printers have a wide range of medical applications and they offer an easy and affordable way to produce skull models. The acrylonitrile butadiene styrene material is suitable for the production of operable bone models as it faithfully reproduces the mechanical characteristics of bone tissue. Copyright © 2017 Sociedad Española de Neurocirugía. Publicado por Elsevier España, S.L.U. All rights reserved.

  3. Effects of drilling parameters in numerical simulation to the bone temperature elevation

    NASA Astrophysics Data System (ADS)

    Akhbar, Mohd Faizal Ali; Malik, Mukhtar; Yusoff, Ahmad Razlan

    2018-04-01

    Drilling into the bone can produce significant amount of heat which can cause bone necrosis. Understanding the drilling parameters influence to the heat generation is necessary to prevent thermal necrosis to the bone. The aim of this study is to investigate the influence of drilling parameters on bone temperature elevation. Drilling simulations of various combinations of drill bit diameter, rotational speed and feed rate were performed using finite element software DEFORM-3D. Full-factorial design of experiments (DOE) and two way analysis of variance (ANOVA) were utilised to examine the effect of drilling parameters and their interaction influence on the bone temperature. The maximum bone temperature elevation of 58% was demonstrated within the range in this study. Feed rate was found to be the main parameter to influence the bone temperature elevation during the drilling process followed by drill diameter and rotational speed. The interaction between drill bit diameter and feed rate was found to be significantly influence the bone temperature. It is discovered that the use of low rotational speed, small drill bit diameter and high feed rate are able to minimize the elevation of bone temperature for safer surgical operations.

  4. Image processing, geometric modeling and data management for development of a virtual bone surgery system.

    PubMed

    Niu, Qiang; Chi, Xiaoyi; Leu, Ming C; Ochoa, Jorge

    2008-01-01

    This paper describes image processing, geometric modeling and data management techniques for the development of a virtual bone surgery system. Image segmentation is used to divide CT scan data into different segments representing various regions of the bone. A region-growing algorithm is used to extract cortical bone and trabecular bone structures systematically and efficiently. Volume modeling is then used to represent the bone geometry based on the CT scan data. Material removal simulation is achieved by continuously performing Boolean subtraction of the surgical tool model from the bone model. A quadtree-based adaptive subdivision technique is developed to handle the large set of data in order to achieve the real-time simulation and visualization required for virtual bone surgery. A Marching Cubes algorithm is used to generate polygonal faces from the volumetric data. Rendering of the generated polygons is performed with the publicly available VTK (Visualization Tool Kit) software. Implementation of the developed techniques consists of developing a virtual bone-drilling software program, which allows the user to manipulate a virtual drill to make holes with the use of a PHANToM device on a bone model derived from real CT scan data.

  5. A simulator for surgery training: optimal sensory stimuli in a bone pinning simulation

    NASA Astrophysics Data System (ADS)

    Daenzer, Stefan; Fritzsche, Klaus

    2008-03-01

    Currently available low cost haptic devices allow inexpensive surgical training with no risk to patients. Major drawbacks of lower cost devices include limited maximum feedback force and the incapability to expose occurring moments. Aim of this work was the design and implementation of a surgical simulator that allows the evaluation of multi-sensory stimuli in order to overcome the occurring drawbacks. The simulator was built following a modular architecture to allow flexible combinations and thorough evaluation of different multi-sensory feedback modules. A Kirschner-Wire (K-Wire) tibial fracture fixation procedure was defined and implemented as a first test scenario. A set of computational metrics has been derived from the clinical requirements of the task to objectively assess the trainees performance during simulation. Sensory feedback modules for haptic and visual feedback have been developed, each in a basic and additionally in an enhanced form. First tests have shown that specific visual concepts can overcome some of the drawbacks coming along with low cost haptic devices. The simulator, the metrics and the surgery scenario together represent an important step towards a better understanding of the perception of multi-sensory feedback in complex surgical training tasks. Field studies on top of the architecture can open the way to risk-less and inexpensive surgical simulations that can keep up with traditional surgical training.

  6. Evaluation of a haptics-based virtual reality temporal bone simulator for anatomy and surgery training.

    PubMed

    Fang, Te-Yung; Wang, Pa-Chun; Liu, Chih-Hsien; Su, Mu-Chun; Yeh, Shih-Ching

    2014-02-01

    Virtual reality simulation training may improve knowledge of anatomy and surgical skills. We evaluated a 3-dimensional, haptic, virtual reality temporal bone simulator for dissection training. The subjects were 7 otolaryngology residents (3 training sessions each) and 7 medical students (1 training session each). The virtual reality temporal bone simulation station included a computer with software that was linked to a force-feedback hand stylus, and the system recorded performance and collisions with vital anatomic structures. Subjects performed virtual reality dissections and completed questionnaires after the training sessions. Residents and students had favorable responses to most questions of the technology acceptance model (TAM) questionnaire. The average TAM scores were above neutral for residents and medical students in all domains, and the average TAM score for residents was significantly higher for the usefulness domain and lower for the playful domain than students. The average satisfaction questionnaire for residents showed that residents had greater overall satisfaction with cadaver temporal bone dissection training than training with the virtual reality simulator or plastic temporal bone. For medical students, the average comprehension score was significantly increased from before to after training for all anatomic structures. Medical students had significantly more collisions with the dura than residents. The residents had similar mean performance scores after the first and third training sessions for all dissection procedures. The virtual reality temporal bone simulator provided satisfactory training for otolaryngology residents and medical students. Copyright © 2013. Published by Elsevier Ireland Ltd.

  7. Mastoidectomy performance assessment of virtual simulation training using final-product analysis.

    PubMed

    Andersen, Steven A W; Cayé-Thomasen, Per; Sørensen, Mads S

    2015-02-01

    The future development of integrated automatic assessment in temporal bone virtual surgical simulators calls for validation against currently established assessment tools. This study aimed to explore the relationship between mastoidectomy final-product performance assessment in virtual simulation and traditional dissection training. Prospective trial with blinding. A total of 34 novice residents performed a mastoidectomy on the Visible Ear Simulator and on a cadaveric temporal bone. Two blinded senior otologists assessed the final-product performance using a modified Welling scale. The simulator gathered basic metrics on time, steps, and volumes in relation to the on-screen tutorial and collisions with vital structures. Substantial inter-rater reliability (kappa = 0.77) for virtual simulation and moderate inter-rater reliability (kappa = 0.59) for dissection final-product assessment was found. The simulation and dissection performance scores had significant correlation (P = .014). None of the basic simulator metrics correlated significantly with the final-product score except for number of steps completed in the simulator. A modified version of a validated final-product performance assessment tool can be used to assess mastoidectomy on virtual temporal bones. Performance assessment of virtual mastoidectomy could potentially save the use of cadaveric temporal bones for more advanced training when a basic level of competency in simulation has been achieved. NA. © 2014 The American Laryngological, Rhinological and Otological Society, Inc.

  8. Real-time mandibular angle reduction surgical simulation with haptic rendering.

    PubMed

    Wang, Qiong; Chen, Hui; Wu, Wen; Jin, Hai-Yang; Heng, Pheng-Ann

    2012-11-01

    Mandibular angle reduction is a popular and efficient procedure widely used to alter the facial contour. The primary surgical instruments, the reciprocating saw and the round burr, employed in the surgery have a common feature: operating at a high-speed. Generally, inexperienced surgeons need a long-time practice to learn how to minimize the risks caused by the uncontrolled contacts and cutting motions in manipulation of instruments with high-speed reciprocation or rotation. A virtual reality-based surgical simulator for the mandibular angle reduction was designed and implemented on a CUDA-based platform in this paper. High-fidelity visual and haptic feedbacks are provided to enhance the perception in a realistic virtual surgical environment. The impulse-based haptic models were employed to simulate the contact forces and torques on the instruments. It provides convincing haptic sensation for surgeons to control the instruments under different reciprocation or rotation velocities. The real-time methods for bone removal and reconstruction during surgical procedures have been proposed to support realistic visual feedbacks. The simulated contact forces were verified by comparing against the actual force data measured through the constructed mechanical platform. An empirical study based on the patient-specific data was conducted to evaluate the ability of the proposed system in training surgeons with various experiences. The results confirm the validity of our simulator.

  9. Geometric and mechanical evaluation of 3D-printing materials for skull base anatomical education and endoscopic surgery simulation - A first step to create reliable customized simulators.

    PubMed

    Favier, Valentin; Zemiti, Nabil; Caravaca Mora, Oscar; Subsol, Gérard; Captier, Guillaume; Lebrun, Renaud; Crampette, Louis; Mondain, Michel; Gilles, Benjamin

    2017-01-01

    Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor), polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling. All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error). Local accuracy was better in polycarbonate (0.09mm) and polyamide (0.15mm) than in Multicolor (0.90mm) and resin (0.86mm). Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6-3.5 times higher than in bone. For polycarbonate, forces applied were 1.6-2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor. Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety.

  10. Is Surgical Navigation Useful During Closed Reduction of Nasal Bone Fractures?

    PubMed

    Kim, Seon Tae; Jung, Joo Hyun; Kang, Il Gyu

    2017-05-01

    To report the case of a 42-year-old woman with a nasal bone fracture that was easily treated using a surgical navigation system. In this clinical report, the authors suggest that intraoperative surgical navigation systems are useful diagnostically and for localizing sites of nasal bone fractures exactly. The patient underwent successful closed reduction of the nasal bone fracture. Surgical navigation is a useful tool for identifying nasal bone fracture locations and for guiding closed reduction. Surgical navigation is recommended when nasal bone fractures are complicated or not well reduced using the ordinary method.

  11. Role of cranial and spinal virtual and augmented reality simulation using immersive touch modules in neurosurgical training.

    PubMed

    Alaraj, Ali; Charbel, Fady T; Birk, Daniel; Tobin, Matthew; Tobin, Mathew; Luciano, Cristian; Banerjee, Pat P; Rizzi, Silvio; Sorenson, Jeff; Foley, Kevin; Slavin, Konstantin; Roitberg, Ben

    2013-01-01

    Recent studies have shown that mental script-based rehearsal and simulation-based training improve the transfer of surgical skills in various medical disciplines. Despite significant advances in technology and intraoperative techniques over the last several decades, surgical skills training on neurosurgical operations still carries significant risk of serious morbidity or mortality. Potentially avoidable technical errors are well recognized as contributing to poor surgical outcome. Surgical education is undergoing overwhelming change, as a result of the reduction of work hours and current trends focusing on patient safety and linking reimbursement with clinical outcomes. Thus, there is a need for adjunctive means for neurosurgical training, which is a recent advancement in simulation technology. ImmersiveTouch is an augmented reality system that integrates a haptic device and a high-resolution stereoscopic display. This simulation platform uses multiple sensory modalities, re-creating many of the environmental cues experienced during an actual procedure. Modules available include ventriculostomy, bone drilling, percutaneous trigeminal rhizotomy, and simulated spinal modules such as pedicle screw placement, vertebroplasty, and lumbar puncture. We present our experience with the development of such augmented reality neurosurgical modules and the feedback from neurosurgical residents.

  12. Role of Cranial and Spinal Virtual and Augmented Reality Simulation Using Immersive Touch Modules in Neurosurgical Training

    PubMed Central

    Alaraj, Ali; Charbel, Fady T.; Birk, Daniel; Tobin, Mathew; Luciano, Cristian; Banerjee, Pat P.; Rizzi, Silvio; Sorenson, Jeff; Foley, Kevin; Slavin, Konstantin; Roitberg, Ben

    2013-01-01

    Recent studies have shown that mental script-based rehearsal and simulation-based training improves the transfer of surgical skills in various medical disciplines. Despite significant advances in technology and intraoperative techniques over the last several decades, surgical skills training on neurosurgical operations still carries significant risk of serious morbidity or mortality. Potentially avoidable technical errors are well recognized as contributing to poor surgical outcome. Surgical education is undergoing overwhelming change, with reduction of working hours and current trends to focus on patient’s safety and linking reimbursement with clinical outcomes, and there is a need for adjunctive means for neurosurgical training;this has been recent advancement in simulation technology. ImmersiveTouch (IT) is an augmented reality (AR) system that integrates a haptic device and a high-resolution stereoscopic display. This simulation platform utilizes multiple sensory modalities, recreating many of the environmental cues experienced during an actual procedure. Modules available include ventriculostomy, bone drilling, percutaneous trigeminal rhizotomy, in addition to simulated spinal modules such as pedicle screw placement, vertebroplasty, and lumbar puncture. We present our experience with development of such AR neurosurgical modules and the feedback from neurosurgical residents. PMID:23254799

  13. Optimizing light delivery for a photoacoustic surgical system

    NASA Astrophysics Data System (ADS)

    Eddins, Blackberrie; Lediju Bell, Muyinatu A.

    2017-03-01

    This work explores light delivery optimization for a photoacoustic surgical system previously proposed to provide real-time, intraoperative visualization of the internal carotid arteries hidden by bone during minimally invasive neurosurgeries. Monte Carlo simulations were employed to study 3D light propagation in tissue. For a 2.4 mm diameter drill shaft and 2.9 mm spherical drill tip, the optimal fiber distance from the drill shaft was 2 mm, determined from the maximum normalized fluence seen by the artery. A single fiber was insufficient to deliver light to arteries separated by a minimum of 8 mm. Using similar drill geometry and the optimal 2 mm fiber-to-drill shaft distance, Zemax ray tracing simulations were employed to propagate a 950 nm wavelength Gaussian beam through one or more 600 μm core diameter optical fibers, and the resulting optical beam profile was detected on the representative bone surface. For equally spaced fibers, a single merged optical profile formed with 7 or more fibers, determined by thresholding the resulting light profile images at 1/e times the maximum intensity. The corresponding spot size was larger than that of a single fiber transmitting the same input energy, thus reducing the fluence delivered to the sphenoid bone and enabling higher energies within safety limits. A prototype was designed and built based on these optimization parameters. The methodology we used to optimize our light delivery system to surround surgical tools is generalizable to multiple interventional photoacoustic applications.

  14. Collaborative voxel-based surgical virtual environments.

    PubMed

    Acosta, Eric; Muniz, Gilbert; Armonda, Rocco; Bowyer, Mark; Liu, Alan

    2008-01-01

    Virtual Reality-based surgical simulators can utilize Collaborative Virtual Environments (C-VEs) to provide team-based training. To support real-time interactions, C-VEs are typically replicated on each user's local computer and a synchronization method helps keep all local copies consistent. This approach does not work well for voxel-based C-VEs since large and frequent volumetric updates make synchronization difficult. This paper describes a method that allows multiple users to interact within a voxel-based C-VE for a craniotomy simulator being developed. Our C-VE method requires smaller update sizes and provides faster synchronization update rates than volumetric-based methods. Additionally, we address network bandwidth/latency issues to simulate networked haptic and bone drilling tool interactions with a voxel-based skull C-VE.

  15. Computer-based planning of optimal donor sites for autologous osseous grafts

    NASA Astrophysics Data System (ADS)

    Krol, Zdzislaw; Chlebiej, Michal; Zerfass, Peter; Zeilhofer, Hans-Florian U.; Sader, Robert; Mikolajczak, Pawel; Keeve, Erwin

    2002-05-01

    Bone graft surgery is often necessary for reconstruction of craniofacial defects after trauma, tumor, infection or congenital malformation. In this operative technique the removed or missing bone segment is filled with a bone graft. The mainstay of the craniofacial reconstruction rests with the replacement of the defected bone by autogeneous bone grafts. To achieve sufficient incorporation of the autograft into the host bone, precise planning and simulation of the surgical intervention is required. The major problem is to determine as accurately as possible the donor site where the graft should be dissected from and to define the shape of the desired transplant. A computer-aided method for semi-automatic selection of optimal donor sites for autografts in craniofacial reconstructive surgery has been developed. The non-automatic step of graft design and constraint setting is followed by a fully automatic procedure to find the best fitting position. In extension to preceding work, a new optimization approach based on the Levenberg-Marquardt method has been implemented and embedded into our computer-based surgical planning system. This new technique enables, once the pre-processing step has been performed, selection of the optimal donor site in time less than one minute. The method has been applied during surgery planning step in more than 20 cases. The postoperative observations have shown that functional results, such as speech and chewing ability as well as restoration of bony continuity were clearly better compared to conventionally planned operations. Moreover, in most cases the duration of the surgical interventions has been distinctly reduced.

  16. [Preparation of simulate craniocerebral models via three dimensional printing technique].

    PubMed

    Lan, Q; Chen, A L; Zhang, T; Zhu, Q; Xu, T

    2016-08-09

    Three dimensional (3D) printing technique was used to prepare the simulate craniocerebral models, which were applied to preoperative planning and surgical simulation. The image data was collected from PACS system. Image data of skull bone, brain tissue and tumors, cerebral arteries and aneurysms, and functional regions and relative neural tracts of the brain were extracted from thin slice scan (slice thickness 0.5 mm) of computed tomography (CT), magnetic resonance imaging (MRI, slice thickness 1mm), computed tomography angiography (CTA), and functional magnetic resonance imaging (fMRI) data, respectively. MIMICS software was applied to reconstruct colored virtual models by identifying and differentiating tissues according to their gray scales. Then the colored virtual models were submitted to 3D printer which produced life-sized craniocerebral models for surgical planning and surgical simulation. 3D printing craniocerebral models allowed neurosurgeons to perform complex procedures in specific clinical cases though detailed surgical planning. It offered great convenience for evaluating the size of spatial fissure of sellar region before surgery, which helped to optimize surgical approach planning. These 3D models also provided detailed information about the location of aneurysms and their parent arteries, which helped surgeons to choose appropriate aneurismal clips, as well as perform surgical simulation. The models further gave clear indications of depth and extent of tumors and their relationship to eloquent cortical areas and adjacent neural tracts, which were able to avoid surgical damaging of important neural structures. As a novel and promising technique, the application of 3D printing craniocerebral models could improve the surgical planning by converting virtual visualization into real life-sized models.It also contributes to functional anatomy study.

  17. Multimodal image registration of the scoliotic torso for surgical planning

    PubMed Central

    2013-01-01

    Background This paper presents a method that registers MRIs acquired in prone position, with surface topography (TP) and X-ray reconstructions acquired in standing position, in order to obtain a 3D representation of a human torso incorporating the external surface, bone structures, and soft tissues. Methods TP and X-ray data are registered using landmarks. Bone structures are used to register each MRI slice using an articulated model, and the soft tissue is confined to the volume delimited by the trunk and bone surfaces using a constrained thin-plate spline. Results The method is tested on 3 pre-surgical patients with scoliosis and shows a significant improvement, qualitatively and using the Dice similarity coefficient, in fitting the MRI into the standing patient model when compared to rigid and articulated model registration. The determinant of the Jacobian of the registration deformation shows higher variations in the deformation in areas closer to the surface of the torso. Conclusions The novel, resulting 3D full torso model can provide a more complete representation of patient geometry to be incorporated in surgical simulators under development that aim at predicting the effect of scoliosis surgery on the external appearance of the patient’s torso. PMID:23289431

  18. Application of a 3-dimensional printed navigation template in Bernese periacetabular osteotomies: A cadaveric study.

    PubMed

    Zhou, You; Kang, Xiaopeng; Li, Chuan; Xu, Xiaoshan; Li, Rong; Wang, Jun; Li, Wei; Luo, Haotian; Lu, Sheng

    2016-12-01

    The aim of the present study was to describe the application of 3D printed templates for intraoperative navigation and simulation of periacetabular osteotomies (PAOs) in a cadaveric model.Five cadaveric specimens (10 sides) underwent thin-slice computed tomographic scans of the ala of ilium downwards to the proximal end of femoral shaft. Bernese PAO was performed. Using Mimics v10.1 software (Materialise, Leuven, Belgium), 3D computed tomographic reconstructions were created and the 4 standard PAO bone cuts-ischial, pubic, anterior, and posterior aspects of the ilium-as well as rotation of the dislocated acetabular bone blocks were simulated for each specimen. Using these data, custom 3D printed bone-drilling templates of the pelvis were manufactured, to guide surgical placement of the PAO bone cuts. An angle fix wedge was designed and printed, to help accurately achieve the predetermined rotation angle of the acetabular bone block. Each specimen underwent a conventional PAO. Preoperative, postsimulation, and postoperative lateral center-edge angles, acetabular indices, extrusion indices, and femoral head coverage were measured and compared; P and t values were calculated for above-mentioned measurements while comparing preoperative and postoperative data, and also in postsimulation and postoperative data comparison.All 10 PAO osteotomies were successfully completed using the 3D printed bone-drilling template and angle fix wedge. No osteotomy entered the hip joint and a single posterior column fracture was observed. Comparison of preoperative and postoperative measurements of the 10 sides showed statistically significant changes, whereas no statistically significant differences between postsimulation and postoperative values were noted, demonstrating the accuracy and utility of the 3D printed templates.The application of patient-specific 3D printed bone-drilling and rotation templates in PAO is feasible and may facilitate improved clinical outcomes, through the use of precise presurgical planning and reduced surgical complications with the precisely guided bone drilling.

  19. Mastoidectomy simulation with combined visual and haptic feedback.

    PubMed

    Agus, Marco; Giachetti, Andrea; Gobbetti, Enrico; Zanetti, Gianluigi; Zorcolo, Antonio; John, Nigel W; Stone, Robert J

    2002-01-01

    Mastoidectomy is one of the most common surgical procedures relating to the petrous bone. In this paper we describe our preliminary results in the realization of a virtual reality mastoidectomy simulator. Our system is designed to work on patient-specific volumetric object models directly derived from 3D CT and MRI images. The paper summarizes the detailed task analysis performed in order to define the system requirements, introduces the architecture of the prototype simulator, and discusses the initial feedback received from selected end users.

  20. Evaluation of the parameters affecting bone temperature during drilling using a three-dimensional dynamic elastoplastic finite element model.

    PubMed

    Chen, Yung-Chuan; Tu, Yuan-Kun; Zhuang, Jun-Yan; Tsai, Yi-Jung; Yen, Cheng-Yo; Hsiao, Chih-Kun

    2017-11-01

    A three-dimensional dynamic elastoplastic finite element model was constructed and experimentally validated and was used to investigate the parameters which influence bone temperature during drilling, including the drill speed, feeding force, drill bit diameter, and bone density. Results showed the proposed three-dimensional dynamic elastoplastic finite element model can effectively simulate the temperature elevation during bone drilling. The bone temperature rise decreased with an increase in feeding force and drill speed, however, increased with the diameter of drill bit or bone density. The temperature distribution is significantly affected by the drilling duration; a lower drilling speed reduced the exposure duration, decreases the region of the thermally affected zone. The constructed model could be applied for analyzing the influence parameters during bone drilling to reduce the risk of thermal necrosis. It may provide important information for the design of drill bits and surgical drilling powers.

  1. Geometric and mechanical evaluation of 3D-printing materials for skull base anatomical education and endoscopic surgery simulation – A first step to create reliable customized simulators

    PubMed Central

    Zemiti, Nabil; Caravaca Mora, Oscar; Subsol, Gérard; Captier, Guillaume; Lebrun, Renaud; Crampette, Louis; Mondain, Michel; Gilles, Benjamin

    2017-01-01

    Introduction Endoscopic skull base surgery allows minimal invasive therapy through the nostrils to treat infectious or tumorous diseases. Surgical and anatomical education in this field is limited by the lack of validated training models in terms of geometric and mechanical accuracy. We choose to evaluate several consumer-grade materials to create a patient-specific 3D-printed skull base model for anatomical learning and surgical training. Methods Four 3D-printed consumer-grade materials were compared to human cadaver bone: calcium sulfate hemihydrate (named Multicolor), polyamide, resin and polycarbonate. We compared the geometric accuracy, forces required to break thin walls of materials and forces required during drilling. Results All materials had an acceptable global geometric accuracy (from 0.083mm to 0.203mm of global error). Local accuracy was better in polycarbonate (0.09mm) and polyamide (0.15mm) than in Multicolor (0.90mm) and resin (0.86mm). Resin and polyamide thin walls were not broken at 200N. Forces needed to break Multicolor thin walls were 1.6–3.5 times higher than in bone. For polycarbonate, forces applied were 1.6–2.5 times higher. Polycarbonate had a mode of fracture similar to the cadaver bone. Forces applied on materials during drilling followed a normal distribution except for the polyamide which was melted. Energy spent during drilling was respectively 1.6 and 2.6 times higher on bone than on PC and Multicolor. Conclusion Polycarbonate is a good substitute of human cadaver bone for skull base surgery simulation. Thanks to short lead times and reasonable production costs, patient-specific 3D printed models can be used in clinical practice for pre-operative training, improving patient safety. PMID:29252993

  2. Notes From the Field: Secondary Task Precision for Cognitive Load Estimation During Virtual Reality Surgical Simulation Training.

    PubMed

    Rasmussen, Sebastian R; Konge, Lars; Mikkelsen, Peter T; Sørensen, Mads S; Andersen, Steven A W

    2016-03-01

    Cognitive load (CL) theory suggests that working memory can be overloaded in complex learning tasks such as surgical technical skills training, which can impair learning. Valid and feasible methods for estimating the CL in specific learning contexts are necessary before the efficacy of CL-lowering instructional interventions can be established. This study aims to explore secondary task precision for the estimation of CL in virtual reality (VR) surgical simulation and also investigate the effects of CL-modifying factors such as simulator-integrated tutoring and repeated practice. Twenty-four participants were randomized for visual assistance by a simulator-integrated tutor function during the first 5 of 12 repeated mastoidectomy procedures on a VR temporal bone simulator. Secondary task precision was found to be significantly lower during simulation compared with nonsimulation baseline, p < .001. Contrary to expectations, simulator-integrated tutoring and repeated practice did not have an impact on secondary task precision. This finding suggests that even though considerable changes in CL are reflected in secondary task precision, it lacks sensitivity. In contrast, secondary task reaction time could be more sensitive, but requires substantial postprocessing of data. Therefore, future studies on the effect of CL modifying interventions should weigh the pros and cons of the various secondary task measurements. © The Author(s) 2015.

  3. Mixed reality temporal bone surgical dissector: mechanical design.

    PubMed

    Hochman, Jordan Brent; Sepehri, Nariman; Rampersad, Vivek; Kraut, Jay; Khazraee, Milad; Pisa, Justyn; Unger, Bertram

    2014-08-08

    The Development of a Novel Mixed Reality (MR) Simulation. An evolving training environment emphasizes the importance of simulation. Current haptic temporal bone simulators have difficulty representing realistic contact forces and while 3D printed models convincingly represent vibrational properties of bone, they cannot reproduce soft tissue. This paper introduces a mixed reality model, where the effective elements of both simulations are combined; haptic rendering of soft tissue directly interacts with a printed bone model. This paper addresses one aspect in a series of challenges, specifically the mechanical merger of a haptic device with an otic drill. This further necessitates gravity cancelation of the work assembly gripper mechanism. In this system, the haptic end-effector is replaced by a high-speed drill and the virtual contact forces need to be repositioned to the drill tip from the mid wand. Previous publications detail generation of both the requisite printed and haptic simulations. Custom software was developed to reposition the haptic interaction point to the drill tip. A custom fitting, to hold the otic drill, was developed and its weight was offset using the haptic device. The robustness of the system to disturbances and its stable performance during drilling were tested. The experiments were performed on a mixed reality model consisting of two drillable rapid-prototyped layers separated by a free-space. Within the free-space, a linear virtual force model is applied to simulate drill contact with soft tissue. Testing illustrated the effectiveness of gravity cancellation. Additionally, the system exhibited excellent performance given random inputs and during the drill's passage between real and virtual components of the model. No issues with registration at model boundaries were encountered. These tests provide a proof of concept for the initial stages in the development of a novel mixed-reality temporal bone simulator.

  4. Three-dimensional visualization system as an aid for facial surgical planning

    NASA Astrophysics Data System (ADS)

    Barre, Sebastien; Fernandez-Maloigne, Christine; Paume, Patricia; Subrenat, Gilles

    2001-05-01

    We present an aid for facial deformities treatment. We designed a system for surgical planning and prediction of human facial aspect after maxillo-facial surgery. We study the 3D reconstruction process of the tissues involved in the simulation, starting from CT acquisitions. 3D iso-surfaces meshes of soft tissues and bone structures are built. A sparse set of still photographs is used to reconstruct a 360 degree(s) texture of the facial surface and increase its visual realism. Reconstructed objects are inserted into an object-oriented, portable and scriptable visualization software allowing the practitioner to manipulate and visualize them interactively. Several LODs (Level-Of- Details) techniques are used to ensure usability. Bone structures are separated and moved by means of cut planes matching orthognatic surgery procedures. We simulate soft tissue deformations by creating a physically-based springs model between both tissues. The new static state of the facial model is computed by minimizing the energy of the springs system to achieve equilibrium. This process is optimized by transferring informations like participation hints at vertex-level between a warped generic model and the facial mesh.

  5. Modeling bicortical screws under a cantilever bending load.

    PubMed

    James, Thomas P; Andrade, Brendan A

    2013-12-01

    Cyclic loading of surgical plating constructs can precipitate bone screw failure. As the frictional contact between the plate and the bone is lost, cantilever bending loads are transferred from the plate to the head of the screw, which over time causes fatigue fracture from cyclic bending. In this research, analytical models using beam mechanics theory were developed to describe the elastic deflection of a bicortical screw under a statically applied load. Four analytical models were developed to simulate the various restraint conditions applicable to bicortical support of the screw. In three of the models, the cortical bone near the tip of the screw was simulated by classical beam constraints (1) simply supported, (2) cantilever, and (3) split distributed load. In the final analytical model, the cortices were treated as an elastic foundation, whereby the response of the constraint was proportional to screw deflection. To test the predictive ability of the new analytical models, 3.5 mm cortical bone screws were tested in a synthetic bone substitute. A novel instrument was developed to measure the bending deflection of screws under radial loads (225 N, 445 N, and 670 N) applied by a surrogate surgical plate at the head of the screw. Of the four cases considered, the analytical model utilizing an elastic foundation most accurately predicted deflection at the screw head, with an average difference of 19% between the measured and predicted results. Determination of the bending moments from the elastic foundation model revealed that a maximum moment of 2.3 N m occurred near the middle of the cortical wall closest to the plate. The location of the maximum bending moment along the screw axis was consistent with the fracture location commonly observed in clinical practice.

  6. Biomechanical Three-Dimensional Finite Element Analysis of Single Implant-Supported Prostheses in the Anterior Maxilla, with Different Surgical Techniques and Implant Types.

    PubMed

    Verri, Fellippo Ramos; Santiago, Joel Ferreira; Almeida, Daniel Augusto; de Souza Batista, Victor Eduardo; Araujo Lemos, Cleidiel Aparecido; Mello, Caroline Cantieri; Pellizzer, Eduardo Piza

    The aim of this study was to use three-dimensional finite element analysis to analyze the stress distribution transferred by single implant-supported prostheses placed in the anterior maxilla using different connections (external hexagon, internal hexagon, or Morse taper), inclinations of the load (0, 30, or 60 degrees), and surgical techniques for placement (monocortical/conventional, bicortical, or bicortical with nasal floor elevation). Nine models representing a bone block of this region were simulated by computer-aided design software (InVesalius, Rhinoceros, SolidWorks). Each model received one implant, which supported a cemented metalloceramic crown. Using FEMAP software, finite elements were discretized while simulating a 178-N load at 0, 30, and 60 degrees relative to the long axis of the implant. The problem was solved in NEi Nastran software, and postprocessing was performed in FEMAP. Von Mises stress and maximum principal stress maps were made. The von Mises stress analysis revealed that stress increased with increasing inclination of the load, from 0 to 30 to 60 degrees. Morse taper implants showed less stress concentration around the cervical and apical areas of the implant. The bicortical technique, associated or not with nasal floor elevation, contributed to decreasing the stress concentration in the apical area of the implant. Maximum principal stress analysis showed that the increase in inclination was proportional to the increase in stress on the bone tissue in the cervical area. Lower stress concentrations in the cortical bone were obtained with Morse taper implants and the bicortical technique compared with other connections and surgical techniques, respectively. Increasing the inclination of the applied force relative to the long axis of the implant tended to overload the peri-implant bone tissue and the internal structure of the implants. The Morse taper connection and bicortical techniques seemed to be more favorable than other connections or techniques, respectively, for restoring the anterior maxilla.

  7. Juvenile Swine Surgical Alveolar Cleft Model to Test Novel Autologous Stem Cell Therapies

    PubMed Central

    Caballero, Montserrat; Morse, Justin C.; Halevi, Alexandra E.; Emodi, Omri; Pharaon, Michael R.; Wood, Jeyhan S.

    2015-01-01

    Reconstruction of craniofacial congenital bone defects has historically relied on autologous bone grafts. Engineered bone using mesenchymal stem cells from the umbilical cord on electrospun nanomicrofiber scaffolds offers an alternative to current treatments. This preclinical study presents the development of a juvenile swine model with a surgically created maxillary cleft defect for future testing of tissue-engineered implants for bone generation. Five-week-old pigs (n=6) underwent surgically created maxillary (alveolar) defects to determine critical-sized defect and the quality of treatment outcomes with rib, iliac crest cancellous bone, and tissue-engineered scaffolds. Pigs were sacrificed at 1 month. Computed tomography scans were obtained at days 0 and 30, at the time of euthanasia. Histological evaluation was performed on newly formed bone within the surgical defect. A 1 cm surgically created defect healed with no treatment, the 2 cm defect did not heal. A subsequently created 1.7 cm defect, physiologically similar to a congenitally occurring alveolar cleft in humans, from the central incisor to the canine, similarly did not heal. Rib graft treatment did not incorporate into adjacent normal bone; cancellous bone and the tissue-engineered graft healed the critical-sized defect. This work establishes a juvenile swine alveolar cleft model with critical-sized defect approaching 1.7 cm. Both cancellous bone and tissue engineered graft generated bridging bone formation in the surgically created alveolar cleft defect. PMID:25837453

  8. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  9. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  10. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  11. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  12. 21 CFR 888.4540 - Orthopedic manual surgical instrument.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., femoral neck punch, socket pusher, reamer, rongeur, scissors, screwdriver, bone skid, staple driver, bone screw starter, surgical stripper, tamp, bone tap, trephine, wire twister, and wrench. (b) Classification...

  13. Mechanical evaluation of the SLM fabricated, stiffness-matched, mandibular bone fixation plates

    NASA Astrophysics Data System (ADS)

    Jahadakbar, Ahmadreza; Shayesteh Moghaddam, Narges; Amerinatanzi, Amirhesam; Dean, David; Elahinia, Mohammad

    2018-03-01

    The standard of the care for the treatment of mandibular segmental defects is the use of Ti-6Al-4V bone fixation plates and screws to immobilize the grafted bone and the host mandible. While Ti-6Al-4V bone fixation plates provide strong immobilization during the healing period, they may disturb the stress distribution in the repaired mandible. The highly stiff Ti-6Al-4V fixation carries a great portion of the load which was previously borne by the mandible, and stress shielding may occur on the surrounding cortical bone. Based on the bone remodeling theory, stress shielding causes bone resorption in the effected region and may eventually lead to the failure of the surgical reconstruction. To address this issue, we have developed a new generation of the patient-specific, porous NiTi bone fixation plates which benefit from stiffness-matching of the adjacent bone. Using the CT scan data of the patient's defective mandible, the geometry for the required bone fixation plates is designed and the stiffness of the surrounding regions is measured. By introducing specific level and type of porosity to the bone fixation plate, its stiffness can be tuned. Finite Element simulations has verified the reduced level of stress shielding on the reconstructed mandible, in case of using the proposed bone fixation plates. Selective Lase Sintering has been used for fabrication of the porous NiTi bone fixation plates with six different levels of stiffness. Finite element simulations, and mechanical tests have been done to verify the performance of the fabricated parts resulting from our design and fabrication method.

  14. Successful correction of tibial bone deformity through multiple surgical procedures, liquid nitrogen-pretreated bone tumor autograft, three-dimensional external fixation, and internal fixation in a patient with primary osteosarcoma: a case report.

    PubMed

    Takeuchi, Akihiko; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Watanabe, Koji; Miwa, Shinji; Tsuchiya, Hiroyuki

    2015-12-07

    In a previous report, we described a method of reconstruction using tumor-bearing autograft treated by liquid nitrogen for malignant bone tumor. Here we present the first case of bone deformity correction following a tumor-bearing frozen autograft via three-dimensional computerized reconstruction after multiple surgeries. A 16-year-old female student presented with pain in the left lower leg and was diagnosed with a low-grade central tibial osteosarcoma. Surgical bone reconstruction was performed using a tumor-bearing frozen autograft. Bone union was achieved at 7 months after the first surgical procedure. However, local tumor recurrence and lung metastases occurred 2 years later, at which time a second surgical procedure was performed. Five years later, the patient developed a 19° varus deformity and underwent a third surgical procedure, during which an osteotomy was performed using the Taylor Spatial Frame three-dimensional external fixation technique. A fourth corrective surgical procedure was performed in which internal fixation was achieved with a locking plate. Two years later, and 10 years after the initial diagnosis of tibial osteosarcoma, the bone deformity was completely corrected, and the patient's limb function was good. We present the first report in which a bone deformity due to a primary osteosarcoma was corrected using a tumor-bearing frozen autograft, followed by multiple corrective surgical procedures that included osteotomy, three-dimensional external fixation, and internal fixation.

  15. Computational biomechanics of bone's responses to dental prostheses - osseointegration, remodeling and resorption

    NASA Astrophysics Data System (ADS)

    Li, Wei; Rungsiyakull, Chaiy; Field, Clarice; Lin, Daniel; Zhang, Leo; Li, Qing; Swain, Michael

    2010-06-01

    Clinical and experimental studies showed that human bone has the ability to remodel itself to better adapt to its biomechanical environment by changing both its material properties and geometry. As a consequence of the rapid development and extensive applications of major dental restorations such as implantation and fixed partial denture (FPD), the effect of bone remodeling on the success of a dental restorative surgery is becoming critical for prosthetic design and pre-surgical assessment. This paper aims to provide a computational biomechanics framework to address dental bone's responses as a result of dental restoration. It explored three important issues of resorption, apposition and osseointegration in terms of remodeling simulation. The published remodeling data in long bones were regulated to drive the computational remodeling prediction for the dental bones by correlating the results to clinical data. It is anticipated that the study will provide a more predictive model of dental bone response and help develop a new design methodology for patient-specific dental prosthetic restoration.

  16. 3D Printed Surgical Simulation Models as educational tool by maxillofacial surgeons.

    PubMed

    Werz, S M; Zeichner, S J; Berg, B-I; Zeilhofer, H-F; Thieringer, F

    2018-02-26

    The aim of this study was to evaluate whether inexpensive 3D models can be suitable to train surgical skills to dental students or oral and maxillofacial surgery residents. Furthermore, we wanted to know which of the most common filament materials, acrylonitrile butadiene styrene (ABS) or polylactic acid (PLA), can better simulate human bone according to surgeons' subjective perceptions. Upper and lower jaw models were produced with common 3D desktop printers, ABS and PLA filament and silicon rubber for soft tissue simulation. Those models were given to 10 blinded, experienced maxillofacial surgeons to perform sinus lift and wisdom teeth extraction. Evaluation was made using a questionnaire. Because of slightly different density and filament prices, each silicon-covered model costs between 1.40-1.60 USD (ABS) and 1.80-2.00 USD (PLA) based on 2017 material costs. Ten experienced raters took part in the study. All raters deemed the models suitable for surgical education. No significant differences between ABS and PLA were found, with both having distinct advantages. The study demonstrated that 3D printing with inexpensive printing filaments is a promising method for training oral and maxillofacial surgery residents or dental students in selected surgical procedures. With a simple and cost-efficient manufacturing process, models of actual patient cases can be produced on a small scale, simulating many kinds of surgical procedures. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Anatomy-Specific Virtual Reality Simulation in Temporal Bone Dissection: Perceived Utility and Impact on Surgeon Confidence.

    PubMed

    Locketz, Garrett D; Lui, Justin T; Chan, Sonny; Salisbury, Kenneth; Dort, Joseph C; Youngblood, Patricia; Blevins, Nikolas H

    2017-06-01

    Objective To evaluate the effect of anatomy-specific virtual reality (VR) surgical rehearsal on surgeon confidence and temporal bone dissection performance. Study Design Prospective pre- and poststudy of a novel virtual surgical rehearsal platform. Setting Academic otolaryngology-head and neck surgery residency training programs. Subjects and Methods Sixteen otolaryngology-head and neck surgery residents from 2 North American training institutions were recruited. Surveys were administered to assess subjects' baseline confidence in performing 12 subtasks of cortical mastoidectomy with facial recess. A cadaver temporal bone was randomly assigned to each subject. Cadaver specimens were scanned with a clinical computed tomography protocol, allowing the creation of anatomy-specific models for use in a VR surgical rehearsal platform. Subjects then rehearsed a virtual mastoidectomy on data sets derived from their specimens. Surgical confidence surveys were administered again. Subjects then dissected assigned cadaver specimens, which were blindly graded with a modified Welling scale. A final survey assessed the perceived utility of rehearsal on dissection performance. Results Of 16 subjects, 14 (87.5%) reported a significant increase in overall confidence after conducting an anatomy-specific VR rehearsal. A significant correlation existed between perceived utility of rehearsal and confidence improvement. The effect of rehearsal on confidence was dependent on trainee experience and the inherent difficulty of the surgical subtask. Postrehearsal confidence correlated strongly with graded dissection performance. Subjects rated anatomy-specific rehearsal as having a moderate to high contribution to their dissection performance. Conclusion Anatomy-specific virtual rehearsal improves surgeon confidence in performing mastoid dissection, dependent on surgeon experience and task difficulty. The subjective confidence gained through rehearsal correlates positively with subsequent objective dissection performance.

  18. Virtual reality training for improving the skills needed for performing surgery of the ear, nose or throat.

    PubMed

    Piromchai, Patorn; Avery, Alex; Laopaiboon, Malinee; Kennedy, Gregor; O'Leary, Stephen

    2015-09-09

    Virtual reality simulation uses computer-generated imagery to present a simulated training environment for learners. This review seeks to examine whether there is evidence to support the introduction of virtual reality surgical simulation into ear, nose and throat surgical training programmes. 1. To assess whether surgeons undertaking virtual reality simulation-based training achieve surgical ('patient') outcomes that are at least as good as, or better than, those achieved through conventional training methods.2. To assess whether there is evidence from either the operating theatre, or from controlled (simulation centre-based) environments, that virtual reality-based surgical training leads to surgical skills that are comparable to, or better than, those achieved through conventional training. The Cochrane Ear, Nose and Throat Disorders Group (CENTDG) Trials Search Co-ordinator searched the CENTDG Trials Register; Central Register of Controlled Trials (CENTRAL 2015, Issue 6); PubMed; EMBASE; ERIC; CINAHL; Web of Science; ClinicalTrials.gov; ICTRP and additional sources for published and unpublished trials. The date of the search was 27 July 2015. We included all randomised controlled trials and controlled trials comparing virtual reality training and any other method of training in ear, nose or throat surgery. We used the standard methodological procedures expected by The Cochrane Collaboration. We evaluated both technical and non-technical aspects of skill competency. We included nine studies involving 210 participants. Out of these, four studies (involving 61 residents) assessed technical skills in the operating theatre (primary outcomes). Five studies (comprising 149 residents and medical students) assessed technical skills in controlled environments (secondary outcomes). The majority of the trials were at high risk of bias. We assessed the GRADE quality of evidence for most outcomes across studies as 'low'. Operating theatre environment (primary outcomes) In the operating theatre, there were no studies that examined two of three primary outcomes: real world patient outcomes and acquisition of non-technical skills. The third primary outcome (technical skills in the operating theatre) was evaluated in two studies comparing virtual reality endoscopic sinus surgery training with conventional training. In one study, psychomotor skill (which relates to operative technique or the physical co-ordination associated with instrument handling) was assessed on a 10-point scale. A second study evaluated the procedural outcome of time-on-task. The virtual reality group performance was significantly better, with a better psychomotor score (mean difference (MD) 1.66, 95% CI 0.52 to 2.81; 10-point scale) and a shorter time taken to complete the operation (MD -5.50 minutes, 95% CI -9.97 to -1.03). Controlled training environments (secondary outcomes) In a controlled environment five studies evaluated the technical skills of surgical trainees (one study) and medical students (three studies). One study was excluded from the analysis. Surgical trainees: One study (80 participants) evaluated the technical performance of surgical trainees during temporal bone surgery, where the outcome was the quality of the final dissection. There was no difference in the end-product scores between virtual reality and cadaveric temporal bone training. Medical students: Two other studies (40 participants) evaluated technical skills achieved by medical students in the temporal bone laboratory. Learners' knowledge of the flow of the operative procedure (procedural score) was better after virtual reality than conventional training (SMD 1.11, 95% CI 0.44 to 1.79). There was also a significant difference in end-product score between the virtual reality and conventional training groups (SMD 2.60, 95% CI 1.71 to 3.49). One study (17 participants) revealed that medical students acquired anatomical knowledge (on a scale of 0 to 10) better during virtual reality than during conventional training (MD 4.3, 95% CI 2.05 to 6.55). No studies in a controlled training environment assessed non-technical skills. There is limited evidence to support the inclusion of virtual reality surgical simulation into surgical training programmes, on the basis that it can allow trainees to develop technical skills that are at least as good as those achieved through conventional training. Further investigations are required to determine whether virtual reality training is associated with better real world outcomes for patients and the development of non-technical skills. Virtual reality simulation may be considered as an additional learning tool for medical students.

  19. Unicameral bone cyst of the calcaneus - minimally invasive endoscopic surgical treatment. Case report.

    PubMed

    Stoica, Ioan Cristian; Pop, Doina Mihaela; Grosu, Florin

    2017-01-01

    The role of arthroscopic surgery for the treatment of various orthopedic pathologies has greatly improved during the last years. Recent publications showed that benign bone lesion may benefit from this minimally invasive surgical method, in order to minimize the invasiveness and the period of immobilization and to increase visualization. Unicameral bone cysts may be adequately treated by minimally invasive endoscopic surgery. The purpose of the current paper is to present the case report of a patient with a unicameral bone cyst of the calcaneus that underwent endoscopically assisted treatment with curettage and bone grafting with allograft from a bone bank, with emphasis on the surgical technique. Unicameral bone cyst is a benign bone lesion, which can be adequately treated by endoscopic curettage and percutaneous injection of morselized bone allograft in symptomatic patients.

  20. Smoking and Bone Healing - A Risky Surgical Combination

    MedlinePlus

    ... Risky Surgical Combination A A A | Print | Share Smoking and Bone Healing – A Risky Surgical Combination Imagine ... saying that they'd prefer patients to quit smoking. There hasn't been a great deal of ...

  1. Malignant transformation of a unicameral bone cyst in a cat.

    PubMed

    Berger, Björn; Brühschwein, Andreas; Eddicks, Lina; Meyer-Lindenberg, Andrea

    2016-04-01

    A unicameral bone cyst in the proximal humerus of a 3-year-old Norwegian forest cat was diagnosed by dynamic contrast-enhanced magnetic resonance imaging, surgical exploration, and histopathology. Surgical curettage and incorporation of bone cement led to full recovery. An osteosarcoma developed at the surgical site 17 months later. Thoracic radiographs showed pulmonary lesions consistent with metastasis.

  2. Malignant transformation of a unicameral bone cyst in a cat

    PubMed Central

    Berger, Björn; Brühschwein, Andreas; Eddicks, Lina; Meyer-Lindenberg, Andrea

    2016-01-01

    A unicameral bone cyst in the proximal humerus of a 3-year-old Norwegian forest cat was diagnosed by dynamic contrast-enhanced magnetic resonance imaging, surgical exploration, and histopathology. Surgical curettage and incorporation of bone cement led to full recovery. An osteosarcoma developed at the surgical site 17 months later. Thoracic radiographs showed pulmonary lesions consistent with metastasis. PMID:27041754

  3. Evaluation of an antimicrobial surgical glove to inactivate live human immunodeficiency virus following simulated glove puncture.

    PubMed

    Edmiston, Charles E; Zhou, S Steve; Hoerner, Pierre; Krikorian, Raffi; Krepel, Candace J; Lewis, Brian D; Brown, Kellie R; Rossi, Peter J; Graham, Mary Beth; Seabrook, Gary R

    2013-02-01

    Percutaneous injuries associated with cutting instruments, needles, and other sharps (eg, metallic meshes, bone fragments, etc) occur commonly during surgical procedures, exposing members of surgical teams to the risk for contamination by blood-borne pathogens. This study evaluated the efficacy of an innovative integrated antimicrobial glove to reduce transmission of the human immunodeficiency virus (HIV) following a simulated surgical-glove puncture injury. A pneumatically activated puncturing apparatus was used in a surgical-glove perforation model to evaluate the passage of live HIV-1 virus transferred via a contaminated blood-laden needle, using a reference (standard double-layer glove) and an antimicrobial benzalkonium chloride (BKC) surgical glove. The study used 2 experimental designs. In method A, 10 replicates were used in 2 cycles to compare the mean viral load following passage through standard and antimicrobial gloves. In method B, 10 replicates were pooled into 3 aliquots and were used to assess viral passage though standard and antimicrobial test gloves. In both methods, viral viability was assessed by observing the cytopathic effects in human lymphocytic C8166 T-cell tissue culture. Concurrent viral and cell culture viability controls were run in parallel with the experiment's studies. All controls involving tissue culture and viral viability were performed according to study design. Mean HIV viral loads (log(10)TCID(50)) were significantly reduced (P < .01) following passage through the BKC surgical glove compared to passage through the nonantimicrobial glove. The reduction (log reduction and percent viral reduction) of the HIV virus ranged from 1.96 to 2.4 and from 98.9% to 99.6%, respectively, following simulated surgical-glove perforation. Sharps injuries in the operating room pose a significant occupational risk for surgical practitioners. The findings of this study suggest that an innovative antimicrobial glove was effective at significantly (P < .01) reducing the risk for blood-borne virus transfer in a model of simulated glove perforation. Copyright © 2013 Mosby, Inc. All rights reserved.

  4. Design of a multifiber light delivery system for photoacoustic-guided surgery.

    PubMed

    Eddins, Blackberrie; Bell, Muyinatu A Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1 / e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  5. Design of a multifiber light delivery system for photoacoustic-guided surgery

    NASA Astrophysics Data System (ADS)

    Eddins, Blackberrie; Bell, Muyinatu A. Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1/e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  6. Computer-assisted selection of donor sites for autologous grafts

    NASA Astrophysics Data System (ADS)

    Krol, Zdzislaw; Zeilhofer, Hans-Florian U.; Sader, Robert; Hoffmann, Karl-Heinz; Gerhardt, Paul; Horch, Hans-Henning

    1997-05-01

    A new method is proposed for a precise planning of autologous bone grafts in cranio- and maxillofacial surgery. In patients with defects of the facial skeleton, autologous bone transplants can be harvested from various donor sites in the body. The preselection of a donor site depends i.a. on the morphological fit of the available bone mass and the shape of the part that is to be transplanted. A thorough planning and simulation of the surgical intervention based on 3D CT studies leads to a geometrical description and the volumetric characterization of the bone part to be resected and transplanted. Both, an optimal fit and a minimal lesion of the donor site are guidelines in this process. We use surface similarity and voxel similarity measures in order to select the optimal donor region for an individually designed transplant.

  7. Mixed reality temporal bone surgical dissector: mechanical design

    PubMed Central

    2014-01-01

    Objective The Development of a Novel Mixed Reality (MR) Simulation. An evolving training environment emphasizes the importance of simulation. Current haptic temporal bone simulators have difficulty representing realistic contact forces and while 3D printed models convincingly represent vibrational properties of bone, they cannot reproduce soft tissue. This paper introduces a mixed reality model, where the effective elements of both simulations are combined; haptic rendering of soft tissue directly interacts with a printed bone model. This paper addresses one aspect in a series of challenges, specifically the mechanical merger of a haptic device with an otic drill. This further necessitates gravity cancelation of the work assembly gripper mechanism. In this system, the haptic end-effector is replaced by a high-speed drill and the virtual contact forces need to be repositioned to the drill tip from the mid wand. Previous publications detail generation of both the requisite printed and haptic simulations. Method Custom software was developed to reposition the haptic interaction point to the drill tip. A custom fitting, to hold the otic drill, was developed and its weight was offset using the haptic device. The robustness of the system to disturbances and its stable performance during drilling were tested. The experiments were performed on a mixed reality model consisting of two drillable rapid-prototyped layers separated by a free-space. Within the free-space, a linear virtual force model is applied to simulate drill contact with soft tissue. Results Testing illustrated the effectiveness of gravity cancellation. Additionally, the system exhibited excellent performance given random inputs and during the drill’s passage between real and virtual components of the model. No issues with registration at model boundaries were encountered. Conclusion These tests provide a proof of concept for the initial stages in the development of a novel mixed-reality temporal bone simulator. PMID:25927300

  8. VirSSPA- a virtual reality tool for surgical planning workflow.

    PubMed

    Suárez, C; Acha, B; Serrano, C; Parra, C; Gómez, T

    2009-03-01

    A virtual reality tool, called VirSSPA, was developed to optimize the planning of surgical processes. Segmentation algorithms for Computed Tomography (CT) images: a region growing procedure was used for soft tissues and a thresholding algorithm was implemented to segment bones. The algorithms operate semiautomati- cally since they only need seed selection with the mouse on each tissue segmented by the user. The novelty of the paper is the adaptation of an enhancement method based on histogram thresholding applied to CT images for surgical planning, which simplifies subsequent segmentation. A substantial improvement of the virtual reality tool VirSSPA was obtained with these algorithms. VirSSPA was used to optimize surgical planning, to decrease the time spent on surgical planning and to improve operative results. The success rate increases due to surgeons being able to see the exact extent of the patient's ailment. This tool can decrease operating room time, thus resulting in reduced costs. Virtual simulation was effective for optimizing surgical planning, which could, consequently, result in improved outcomes with reduced costs.

  9. Computer-assisted midface reconstruction in Treacher Collins syndrome part 1: skeletal reconstruction.

    PubMed

    Herlin, Christian; Doucet, Jean Charles; Bigorre, Michèle; Khelifa, Hatem Cheikh; Captier, Guillaume

    2013-10-01

    Treacher Collins syndrome (TCS) is a severe and complex craniofacial malformation affecting the facial skeleton and soft tissues. The palate as well as the external and middle ear are also affected, but his prognosis is mainly related to neonatal airway management. Methods of zygomatico-orbital reconstruction are numerous and currently use primarily autologous bone, lyophilized cartilage, alloplastic implants, or even free flaps. This work developed a reliable "customized" method of zygomatico-orbital bony reconstruction using a generic reference model tailored to each patient. From a standard computed tomography (CT) acquisition, we studied qualitatively and quantitatively the skeleton of four individuals with TCS whose age was between 6 and 20 years. In parallel, we studied 40 controls at the same age to obtain a morphometric database of reference. Surgical simulation was carried out using validated software used in craniofacial surgery. The zygomatic hypoplasia was very important quantitatively and morphologically in all TCS individuals. Orbital involvement was mainly morphological, with volumes comparable to the controls of the same age. The control database was used to create three-dimensional computer models to be used in the manufacture of cutting guides for autologous cranial bone grafts or alloplastic implants perfectly adapted to each patient's morphology. Presurgical simulation was also used to fabricate custom positioning guides permitting a simple and reliable surgical procedure. The use of a virtual database allowed us to design a reliable and reproducible skeletal reconstruction method for this rare and complex syndrome. The use of presurgical simulation tools seem essential in this type of craniofacial malformation to increase the reliability of these uncommon and complex surgical procedures, and to ensure stable results over time. Copyright © 2013 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  10. Augmented reality in bone tumour resection: An experimental study.

    PubMed

    Cho, H S; Park, Y K; Gupta, S; Yoon, C; Han, I; Kim, H-S; Choi, H; Hong, J

    2017-03-01

    We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p < 0.05, one-way analysis of variance). The probabilities of a surgeon obtaining a 10 mm surgical margin with a 3 mm tolerance were 90.2% in AR-assisted resections, and 70.7% in conventional resections. We demonstrated that the accuracy of tumour resection was satisfactory with the help of the AR navigation system, with the tumour shown as a virtual template. In addition, this concept made the navigation system simple and available without additional cost or time. Cite this article: H. S. Cho, Y. K. Park, S. Gupta, C. Yoon, I. Han, H-S. Kim, H. Choi, J. Hong. Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137-143. © 2017 Cho et al.

  11. Augmented reality in bone tumour resection

    PubMed Central

    Park, Y. K.; Gupta, S.; Yoon, C.; Han, I.; Kim, H-S.; Choi, H.; Hong, J.

    2017-01-01

    Objectives We evaluated the accuracy of augmented reality (AR)-based navigation assistance through simulation of bone tumours in a pig femur model. Methods We developed an AR-based navigation system for bone tumour resection, which could be used on a tablet PC. To simulate a bone tumour in the pig femur, a cortical window was made in the diaphysis and bone cement was inserted. A total of 133 pig femurs were used and tumour resection was simulated with AR-assisted resection (164 resection in 82 femurs, half by an orthropaedic oncology expert and half by an orthopaedic resident) and resection with the conventional method (82 resection in 41 femurs). In the conventional group, resection was performed after measuring the distance from the edge of the condyle to the expected resection margin with a ruler as per routine clinical practice. Results The mean error of 164 resections in 82 femurs in the AR group was 1.71 mm (0 to 6). The mean error of 82 resections in 41 femurs in the conventional resection group was 2.64 mm (0 to 11) (p < 0.05, one-way analysis of variance). The probabilities of a surgeon obtaining a 10 mm surgical margin with a 3 mm tolerance were 90.2% in AR-assisted resections, and 70.7% in conventional resections. Conclusion We demonstrated that the accuracy of tumour resection was satisfactory with the help of the AR navigation system, with the tumour shown as a virtual template. In addition, this concept made the navigation system simple and available without additional cost or time. Cite this article: H. S. Cho, Y. K. Park, S. Gupta, C. Yoon, I. Han, H-S. Kim, H. Choi, J. Hong. Augmented reality in bone tumour resection: An experimental study. Bone Joint Res 2017;6:137–143. PMID:28258117

  12. Effects of positioning on radiographic measurements of ankle morphology: a computerized tomography-based simulation study

    PubMed Central

    2013-01-01

    Background Measurements of the morphology of the ankle joint, performed mostly for surgical planning of total ankle arthroplasty and for collecting data for total ankle prosthesis design, are often made on planar radiographs, and therefore can be very sensitive to the positioning of the joint during imaging. The current study aimed to compare ankle morphological measurements using CT-generated 2D images with gold standard values obtained from 3D CT data; to determine the sensitivity of the 2D measurements to mal-positioning of the ankle during imaging; and to quantify the repeatability of the 2D measurements under simulated positioning conditions involving random errors. Method Fifty-eight cadaveric ankles fixed in the neutral joint position (standard pose) were CT scanned, and the data were used to simulate lateral and frontal radiographs under various positioning conditions using digitally reconstructed radiographs (DRR). Results and discussion In the standard pose for imaging, most ankle morphometric parameters measured using 2D images were highly correlated (R > 0.8) to the gold standard values defined by the 3D CT data. For measurements made on the lateral views, the only parameters sensitive to rotational pose errors were longitudinal distances between the most anterior and the most posterior points of the tibial mortise and the tibial profile, which have important implications for determining the optimal cutting level of the bone during arthroplasty. Measurements of the trochlea tali width on the frontal views underestimated the standard values by up to 31.2%, with only a moderate reliability, suggesting that pre-surgical evaluations based on the trochlea tali width should be made with caution in order to avoid inappropriate selection of prosthesis sizes. Conclusions While highly correlated with 3D morphological measurements, some 2D measurements were affected by the bone poses in space during imaging, which may affect surgical decision-making in total ankle arthroplasty, including the amount of bone resection and the selection of the implant sizes. The linear regression equations for the relationship between 2D and 3D measurements will be helpful for correcting the errors in 2D morphometric measurements for clinical applications. PMID:24359413

  13. The surgical management of fibrous dysplasia of bone.

    PubMed

    Stanton, Robert P; Ippolito, Ernesto; Springfield, Dempsey; Lindaman, Lynn; Wientroub, Shlomo; Leet, Arabella

    2012-05-24

    The surgical management of Polyostotic Fibrous Dysplasia (FD) of bone is technically demanding. The most effective methods to manage the associated bone deformity remain unclear. The marked variation in the degree and pattern of bone involvement has made it difficult to acquire data to guide the surgeon's approach to these patients. In light of the paucity of data, but need for guidance, recognized experts in the management of these patients came together at the National Institutes of Health in Bethesda, Maryland as part of an International meeting to address issues related to fibrous dysplasia of bone to discuss and refine their recommendations regarding the surgical indications and preferred methods for the management of these challenging patients. The specific challenges, recommended approaches, and "lessons learned" are presented in hopes that surgeons faced with typical deformities can be guided in the surgical reconstruction of both children and adults with FD.

  14. Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery.

    PubMed

    Kobler, Jan-Philipp; Nuelle, Kathrin; Lexow, G Jakob; Rau, Thomas S; Majdani, Omid; Kahrs, Lueder A; Kotlarski, Jens; Ortmaier, Tobias

    2016-03-01

    Minimally invasive cochlear implantation is a novel surgical technique which requires highly accurate guidance of a drilling tool along a trajectory from the mastoid surface toward the basal turn of the cochlea. The authors propose a passive, reconfigurable, parallel robot which can be directly attached to bone anchors implanted in a patient's skull, avoiding the need for surgical tracking systems. Prior to clinical trials, methods are necessary to patient specifically optimize the configuration of the mechanism with respect to accuracy and stability. Furthermore, the achievable accuracy has to be determined experimentally. A comprehensive error model of the proposed mechanism is established, taking into account all relevant error sources identified in previous studies. Two optimization criteria to exploit the given task redundancy and reconfigurability of the passive robot are derived from the model. The achievable accuracy of the optimized robot configurations is first estimated with the help of a Monte Carlo simulation approach and finally evaluated in drilling experiments using synthetic temporal bone specimen. Experimental results demonstrate that the bone-attached mechanism exhibits a mean targeting accuracy of [Formula: see text] mm under realistic conditions. A systematic targeting error is observed, which indicates that accurate identification of the passive robot's kinematic parameters could further reduce deviations from planned drill trajectories. The accuracy of the proposed mechanism demonstrates its suitability for minimally invasive cochlear implantation. Future work will focus on further evaluation experiments on temporal bone specimen.

  15. Comparison of control and quality of bone cutting by using optical topographical imaging guided mechanical drill and 1070 nm laser with in-line coherent imaging

    NASA Astrophysics Data System (ADS)

    Razani, Marjan; Soudagar, Yasaman; Yu, Karen; Galbraith, Christopher M.; Webster, Paul J. L.; Van Vlack, Cole; Sun, Cuiru; Mariampillai, Adrian; Leung, Michael K. K.; Standish, Beau; Kiehl, Tim-Rasmus; Fraser, James M.; Yang, Victor X. D.

    2013-03-01

    Precision depth control of bone resection is necessary for safe surgical procedures in the spine. In this paper, we compare the control and quality of cutting bovine tail bone, as an ex vivo model of laminectomy and bony resection simulating spinal surgery, planned with micro-CT data and executed using two approaches: (a) mechanical milling guided by optical topographical imaging (OTI) and (b) optical milling using closed-loop inline coherent imaging (ICI) to monitor and control the incision depth of a high-power 1070 nm fiber laser in situ. OTI provides the in situ topology of the 2-dimensional surface of the bone orientation in the mechanical mill which is registered with the treatment plan derived from the micro-CT data. The coregistration allows the plan to be programmed into the mill which is then used as a benchmark of current surgical techniques. For laser cutting, 3D optical land marking with coaxial camera vision and the ICI system is used to coregister the treatment plan. The unstable, carbonization-mediated ablation behaviour of 1070 nm light and the unknown initial geometry of bone leads to unpredictable ablation which substantially limits the depth accuracy of open-loop cutting. However, even with such a non-ideal cutting laser, we demonstrate that ICI provides in situ high-speed feedback that automatically and accurately limits the laser's cut depth to effectively create an all-optical analogue to the mechanical mill.

  16. Radiological Assessment of Bioengineered Bone in a Muscle Flap for the Reconstruction of Critical-Size Mandibular Defect

    PubMed Central

    Al-Fotawei, Randa; Ayoub, Ashraf F.; Heath, Neil; Naudi, Kurt B.; Tanner, K. Elizabeth; Dalby, Matthew J.; McMahon, Jeremy

    2014-01-01

    This study presents a comprehensive radiographic evaluation of bone regeneration within a pedicled muscle flap for the reconstruction of critical size mandibular defect. The surgical defect (20 mm×15 mm) was created in the mandible of ten experimental rabbits. The masseter muscle was adapted to fill the surgical defect, a combination of calcium sulphate/hydroxyapatite cement (CERAMENT™ |SPINE SUPPORT), BMP-7 and rabbit mesenchymal stromal cells (rMSCs) was injected inside the muscle tissue. Radiographic assessment was carried out on the day of surgery and at 4, 8, and 12 weeks postoperatively. At 12 weeks, the animals were sacrificed and cone beam computerized tomography (CBCT) scanning and micro-computed tomography (µ-CT) were carried out. Clinically, a clear layer of bone tissue was identified closely adherent to the border of the surgical defect. Sporadic radio-opaque areas within the surgical defect were detected radiographically. In comparison with the opposite non operated control side, the estimated quantitative scoring of the radio-opacity was 46.6% ±15, the mean volume of the radio-opaque areas was 63.4% ±20. Areas of a bone density higher than that of the mandibular bone (+35% ±25%) were detected at the borders of the surgical defect. The micro-CT analysis revealed thinner trabeculae of the regenerated bone with a more condensed trabecular pattern than the surrounding native bone. These findings suggest a rapid deposition rate of the mineralised tissue and an active remodelling process of the newly regenerated bone within the muscle flap. The novel surgical model of this study has potential clinical application; the assessment of bone regeneration using the presented radiolographic protocol is descriptive and comprehensive. The findings of this research confirm the remarkable potential of local muscle flaps as local bioreactors to induce bone formation for reconstruction of maxillofacial bony defects. PMID:25226170

  17. Patient Preferences Regarding Surgical Interventions for Knee Osteoarthritis

    PubMed Central

    Moorman, Claude T; Kirwan, Tom; Share, Jennifer; Vannabouathong, Christopher

    2017-01-01

    Surgical interventions for knee osteoarthritis (OA) have markedly different procedure attributes and may have dramatic differences in patient desirability. A total of 323 patients with knee OA were included in a dual response, choice-based conjoint analysis to identify the relative preference of 9 different procedure attributes. A model was also developed to simulate how patients might respond if presented with the real-world knee OA procedures, based on conservative assumptions regarding their attributes. The “amount of cutting and removal of the existing bone” required for a procedure had the highest preference score, indicating that these patients considered it the most important attribute. More specifically, a procedure that requires the least amount of bone cutting or removal would be expected to be the most preferred surgical alternative. The model also suggested that patients who are younger and report the highest pain levels and greatest functional limitations would be more likely to opt for surgical intervention. PMID:28974919

  18. [Three-dimensional modeling of mandibular distraction].

    PubMed

    Morgon, L A; Trunde, F; Coudert, J L; Disant, F

    2003-12-01

    Facial hemi-atrophy affects 1 in 4000 or 5000 children. We propose treating this deformation of the 1st branchial arch with the "bone distraction" lengthening technique first described by Ilizarov in the 1950s, which has already been employed with the mandible. We have modelled mandibular distraction in facial hemi-atrophy patients and discuss the benefits of such pre-surgical planning encompassing the assistance of pre- and post-operative as well as surgically coordinated orthodontic therapy. Using X scanner views of a 5 year-old girl patient, we have developed a distraction-simulation software, which makes the pathological side harmonious with the healthy side along the medial sagittal plane. In order to obtain facial symmetry, put bones in balance, and orient the occlusal plane horizontally, essential requisites of occlusal stability, it is necessary: to employ a 2 or 3-dimensional distractor, to pre-plan the distraction and screw positioning, to set up a fixed orthodontic treatment plan prior to beginning distraction therapy.

  19. Face and content validation of a novel three-dimensional printed temporal bone for surgical skills development.

    PubMed

    Da Cruz, M J; Francis, H W

    2015-07-01

    To assess the face and content validity of a novel synthetic, three-dimensional printed temporal bone for surgical skills development and training. A synthetic temporal bone was printed using composite materials and three-dimensional printing technology. Surgical trainees were asked to complete three structured temporal bone dissection exercises. Attitudes and impressions were then assessed using a semi-structured questionnaire. Previous cadaver and real operating experiences were used as a reference. Trainees' experiences of the synthetic temporal bone were analysed in terms of four domains: anatomical realism, usefulness as a training tool, task-based usefulness and overall reactions. Responses across all domains indicated a high degree of acceptance, suggesting that the three-dimensional printed temporal bone was a useful tool in skills development. A sophisticated three-dimensional printed temporal bone that demonstrates face and content validity was developed. The efficiency in cost savings coupled with low associated biohazards make it likely that the printed temporal bone will be incorporated into traditional temporal bone skills development programmes in the near future.

  20. 3D-Printed Craniosynostosis Model: New Simulation Surgical Tool.

    PubMed

    Ghizoni, Enrico; de Souza, João Paulo Sant Ana Santos; Raposo-Amaral, Cassio Eduardo; Denadai, Rafael; de Aquino, Humberto Belém; Raposo-Amaral, Cesar Augusto; Joaquim, Andrei Fernandes; Tedeschi, Helder; Bernardes, Luís Fernando; Jardini, André Luiz

    2018-01-01

    Craniosynostosis is a complex disease once it involves deep anatomic perception, and a minor mistake during surgery can be fatal. The objective of this report is to present novel 3-dimensional-printed polyamide craniosynostosis models that can improve the understanding and treatment complex pathologies. The software InVesalius was used for segmentation of the anatomy image (from 3 patients between 6 and 9 months old). Afterward, the file was transferred to a 3-dimensional printing system and, with the use of an infrared laser, slices of powder PA 2200 were consecutively added to build a polyamide model of cranial bone. The 3 craniosynostosis models allowed fronto-orbital advancement, Pi procedure, and posterior distraction in the operating room environment. All aspects of the craniofacial anatomy could be shown on the models, as well as the most common craniosynostosis pathologic variations (sphenoid wing elevation, shallow orbits, jugular foramen stenosis). Another advantage of our model is its low cost, about 100 U.S. dollars or even less when several models are produced. Simulation is becoming an essential part of medical education for surgical training and for improving surgical safety with adequate planning. This new polyamide craniosynostosis model allowed the surgeons to have realistic tactile feedback on manipulating a child's bone and permitted execution of the main procedures for anatomic correction. It is a low-cost model. Therefore our model is an excellent option for training purposes and is potentially a new important tool to improve the quality of the management of patients with craniosynostosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Effects of Lateral Mass Screw Rod Fixation to the Stability of Cervical Spine after Laminectomy

    NASA Astrophysics Data System (ADS)

    Rosli, Ruwaida; Kashani, Jamal; Kadir, Mohammed Rafiq Abdul

    There are many cases of injury in the cervical spine due to degenerative disorder, trauma or instability. This condition may produce pressure on the spinal cord or on the nerve coming from the spine. The aim of this study was, to analyze the stabilization of the cervical spine after undergoing laminectomy via computational simulation. For that purpose, a three-dimensional finite element (FE) model for the multilevel cervical spine segment (C1-C7) was developed using computed tomography (CT) data. There are various decompression techniques that can be applied to overcome the injury. Usually, decompression procedures will create an unstable spine. Therefore, in these situations, the spine is often surgically restabilized by using fusion and instrumentation. In this study, a lateral mass screw-rod fixation was created to stabilize the cervical spine after laminectomy. Material properties of the titanium alloy were assigned on the implants. The requirements moments and boundary conditions were applied on simulated implanted bone. Result showed that the bone without implant has a higher flexion and extension angle in comparison to the bone with implant under applied 1Nm moment. The bone without implant has maximum stress distribution at the vertebrae and ligaments. However, the bone with implant has maximum stress distribution at the screws and rods. Overall, the lateral mass screw-rod fixation provides stability to the cervical spine after undergoing laminectomy.

  2. Immunolocalization of markers for bone formation during guided bone regeneration in osteopenic rats

    PubMed Central

    TERA, Tábata de Mello; NASCIMENTO, Rodrigo Dias; do PRADO, Renata Falchete; SANTAMARIA, Mauro Pedrine; JARDINI, Maria Aparecida Neves

    2014-01-01

    Objective The aim of this paper was to evaluate the repair of onlay autogenous bone grafts covered or not covered by an expanded polytetrafluoroethylene (e-PTFE) membrane using immunohistochemistry in rats with induced estrogen deficiency. Material and Methods Eighty female rats were randomly divided into two groups: ovariectomized (OVX) and with a simulation of the surgical procedure (SHAM). Each of these groups was again divided into groups with either placement of an autogenous bone graft alone (BG) or an autogenous bone graft associated with an e-PTFE membrane (BGM). Animals were euthanized on days 0, 7, 21, 45, and 60. The specimens were subjected to immunohistochemistry for bone sialoprotein (BSP), osteonectin (ONC), and osteocalcin (OCC). Results All groups (OVX+BG, OVX+BMG, SHAM+BG, and SHAM+BMG) showed greater bone formation, observed between 7 and 21 days, when BSP and ONC staining were more intense. At the 45-day, the bone graft showed direct bonding to the recipient bed in all specimens. The ONC and OCC showed more expressed in granulation tissue, in the membrane groups, independently of estrogen deficiency. Conclusions The expression of bone forming markers was not negatively influenced by estrogen deficiency. However, the markers could be influenced by the presence of the e-PTFE membrane. PMID:25591022

  3. A Hybrid Reality Radiation-free Simulator for Teaching Wire Navigation Skills

    PubMed Central

    Kho, Jenniefer Y.; Johns, Brian D.; Thomas, Geb. W.; Karam, Matthew D.; Marsh, J. Lawrence; Anderson, Donald D.

    2016-01-01

    Objectives Surgical simulation is an increasingly important method to facilitate the acquiring of surgical skills. Simulation can be helpful in developing hip fracture fixation skills because it is a common procedure for which performance can be objectively assessed (i.e., the tip-apex distance). The procedure requires fluoroscopic guidance to drill a wire along an osseous trajectory to a precise position within bone. The objective of this study was to assess the construct validity for a novel radiation-free simulator designed to teach wire navigation skills in hip fracture fixation. Methods Novices (N=30) with limited to no surgical experience in hip fracture fixation and experienced surgeons (N=10) participated. Participants drilled a guide wire in the center-center position of a synthetic femoral head in a hip fracture simulator, using electromagnetic sensors to track the guide wire position. Sensor data were gathered to generate fluoroscopic-like images of the hip and guide wire. Simulator performance of novice and experienced participants was compared to measure construct validity. Results The simulator was able to discriminate the accuracy in guide wire position between novices and experienced surgeons. Experienced surgeons achieved a more accurate tip-apex distance than novices (13 vs 23 mm, respectively, p=0.009). The magnitude of improvement on successive simulator attempts was dependent on level of expertise; tip-apex distance improved significantly in the novice group, while it was unchanged in the experienced group. Conclusions This hybrid reality, radiation-free hip fracture simulator, which combines real-world objects with computer-generated imagery demonstrates construct validity by distinguishing the performance of novices and experienced surgeons. There is a differential effect depending on level of experience, and it could be used as an effective training tool in novice surgeons. PMID:26165262

  4. Complex Osteotomies of Tibial Plateau Malunions Using Computer-Assisted Planning and Patient-Specific Surgical Guides.

    PubMed

    Fürnstahl, Philipp; Vlachopoulos, Lazaros; Schweizer, Andreas; Fucentese, Sandro F; Koch, Peter P

    2015-08-01

    The accurate reduction of tibial plateau malunions can be challenging without guidance. In this work, we report on a novel technique that combines 3-dimensional computer-assisted planning with patient-specific surgical guides for improving reliability and accuracy of complex intraarticular corrective osteotomies. Preoperative planning based on 3-dimensional bone models was performed to simulate fragment mobilization and reduction in 3 cases. Surgical implementation of the preoperative plan using patient-specific cutting and reduction guides was evaluated; benefits and limitations of the approach were identified and discussed. The preliminary results are encouraging and show that complex, intraarticular corrective osteotomies can be accurately performed with this technique. For selective patients with complex malunions around the tibia plateau, this method might be an attractive option, with the potential to facilitate achieving the most accurate correction possible.

  5. Experimental and computational studies on the femoral fracture risk for advanced core decompression.

    PubMed

    Tran, T N; Warwas, S; Haversath, M; Classen, T; Hohn, H P; Jäger, M; Kowalczyk, W; Landgraeber, S

    2014-04-01

    Two questions are often addressed by orthopedists relating to core decompression procedure: 1) Is the core decompression procedure associated with a considerable lack of structural support of the bone? and 2) Is there an optimal region for the surgical entrance point for which the fracture risk would be lowest? As bioresorbable bone substitutes become more and more common and core decompression has been described in combination with them, the current study takes this into account. Finite element model of a femur treated by core decompression with bone substitute was simulated and analyzed. In-vitro compression testing of femora was used to confirm finite element results. The results showed that for core decompression with standard drilling in combination with artificial bone substitute refilling, daily activities (normal walking and walking downstairs) are not risky for femoral fracture. The femoral fracture risk increased successively when the entrance point is located further distal. The critical value of the deviation of the entrance point to a more distal part is about 20mm. The study findings demonstrate that optimal entrance point should locate on the proximal subtrochanteric region in order to reduce the subtrochanteric fracture risk. Furthermore the consistent results of finite element and in-vitro testing imply that the simulations are sufficient. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. HyBAR: hybrid bone-attached robot for joint arthroplasty.

    PubMed

    Song, S; Mor, A; Jaramaz, B

    2009-06-01

    A number of small bone-attached surgical robots have been introduced to overcome some disadvantages of large stand-alone surgical robots. In orthopaedics, increasing demand on minimally invasive joint replacement surgery has also been encouraging small surgical robot developments. Among various technical aspects of such an approach, optimal miniaturization that maintains structural strength for high speed bone removal was investigated. By observing advantages and disadvantages from serial and parallel robot structures, a new hybrid kinematic configuration was designed for a bone-attached robot to perform precision bone removal for cutting the femoral implant cavity during patellofemoral joint arthroplasty surgery. A series of experimental tests were conducted in order to evaluate the performance of the new robot, especially with respect to accuracy of bone preparation. A miniaturized and rigidly-structured robot prototype was developed for minimally invasive bone-attached robotic surgery. A new minimally invasive modular clamping system was also introduced to enhance the robotic procedure. Foam and pig bone experimental results demonstrated a successful implementation of the new robot that eliminated a number of major design problems of a previous prototype. For small bone-attached surgical robots that utilize high speed orthopaedic tools, structural rigidity and clamping mechanism are major design issues. The new kinematic configuration using hinged prismatic joints enabled an effective miniaturization with good structural rigidity. Although minor problems still exist at the prototype stage, the new development would be a significant step towards the practical use of such a robot.

  7. Voluntary run training but not estradiol deficiency alters the tibial bone-soleus muscle functional relationship in mice.

    PubMed

    Warren, Gordon L; Moran, Amy L; Hogan, Harry A; Lin, Angela S; Guldberg, Robert E; Lowe, Dawn A

    2007-11-01

    The study's objective was to investigate how estrogen deficiency and run training affect the tibial bone-soleus muscle functional relationship in mice. Female mice were assigned into one of two surgical conditions, ovariectomy (OVX) or sham ovariectomy (sham), and one of two activity conditions, voluntary wheel running (Run) or sedentary (Sed). To determine whether differences observed between OVX and sham conditions could be attributed to estradiol (E(2)), additional OVX mice were supplemented with E(2). Tibial bones were analyzed for their functional capacities, ultimate load, and stiffness. Soleus muscles were analyzed for their functional capacities, maximal isometric tetanic force (P(o)), and peak eccentric force. The ratios of bone functional capacities to those of muscle were calculated. The bone functional capacities were affected by both surgical condition and activity but more strongly by surgical condition. Ultimate load and stiffness for the sham group were 7-12% greater than those for OVX animals (P = 0.002), whereas only stiffness was greater for Run than for Sed animals (9%; P = 0.015). The muscle functional capacities were affected by both surgical condition and activity; however, in contrast to the bone, the muscle was more affected by activity. P(o) and peak eccentric force were 10-21% greater for Run than for Sed animals (P < or = 0.016), whereas only P(o) was greater in sham than in OVX animals (9%; P = 0.011). The bone-to-muscle ratios of functional capacities were affected by activity but not by surgical condition or E(2) supplementation. Thus a mismatch of bone-muscle function occurred in mice that voluntarily ran on wheels, irrespective of estrogen status.

  8. Correction Capability in the 3 Anatomic Planes of Different Pedicle Screw Designs in Scoliosis Instrumentation.

    PubMed

    Wang, Xiaoyu; Aubin, Carl-Eric; Coleman, John; Rawlinson, Jeremy

    2017-05-01

    Computer simulations to compare the correction capabilities of different pedicle screws in adolescent idiopathic scoliosis (AIS) instrumentations. To compare the correction and resulting bone-screw forces associated with different pedicle screws in scoliosis instrumentations. Pedicle screw fixation is widely used in surgical instrumentation for spinal deformity treatment. Screw design, correction philosophies, and surgical techniques are constantly evolving to achieve better control of the vertebrae and correction of the spinal deformity. Yet, there remains a lack of biomechanical studies that quantify the effects and advantages of different screw designs in terms of correction kinematics. The correction capabilities of fixed-angle, multiaxial, uniaxial, and saddle axial screws were kinematically analyzed, simulated, and compared. These simulations were based on the screw patterns and correction techniques proposed by 2 experienced surgeons for 2 AIS cases. Additional instrumentations were assessed to compare the correction and resulting bone-screw forces associated with each type of screw. The fixed-angle, uniaxial and saddle axial screws had similar kinematic behavior and performed better than multiaxial screws in the coronal and transverse planes (8% and 30% greater simulated corrections, respectively). Uniaxial and multiaxial screws were less effective than fixed-angle and saddle axial screws in transmitting compression/distraction to the anterior spine because of their sagittal plane mobility between the screw head and shank. Only the saddle axial screws allow vertebra angle in the sagittal plane to be independently adjusted. Pedicle screws of different designs performed differently for deformity corrections or for compensating screw placement variations in different anatomic planes. For a given AIS case, screw types should be determined based on the particular instrumentation objectives, the deformity's stiffness and characteristics so as to make the best of the screw designs.

  9. Forces associated with launch into space do not impact bone fracture healing

    NASA Astrophysics Data System (ADS)

    Childress, Paul; Brinker, Alexander; Gong, Cynthia-May S.; Harris, Jonathan; Olivos, David J.; Rytlewski, Jeffrey D.; Scofield, David C.; Choi, Sungshin Y.; Shirazi-Fard, Yasaman; McKinley, Todd O.; Chu, Tien-Min G.; Conley, Carolynn L.; Chakraborty, Nabarun; Hammamieh, Rasha; Kacena, Melissa A.

    2018-02-01

    Segmental bone defects (SBDs) secondary to trauma invariably result in a prolonged recovery with an extended period of limited weight bearing on the affected limb. Soldiers sustaining blast injuries and civilians sustaining high energy trauma typify such a clinical scenario. These patients frequently sustain composite injuries with SBDs in concert with extensive soft tissue damage. For soft tissue injury resolution and skeletal reconstruction a patient may experience limited weight bearing for upwards of 6 months. Many small animal investigations have evaluated interventions for SBDs. While providing foundational information regarding the treatment of bone defects, these models do not simulate limited weight bearing conditions after injury. For example, mice ambulate immediately following anesthetic recovery, and in most cases are normally ambulating within 1-3 days post-surgery. Thus, investigations that combine disuse with bone healing may better test novel bone healing strategies. To remove weight bearing, we have designed a SBD rodent healing study in microgravity (μG) on the International Space Station (ISS) for the Rodent Research-4 (RR-4) Mission, which launched February 19, 2017 on SpaceX CRS-10 (Commercial Resupply Services). In preparation for this mission, we conducted an end-to-end mission simulation consisting of surgical infliction of SBD followed by launch simulation and hindlimb unloading (HLU) studies. In brief, a 2 mm defect was created in the femur of 10 week-old C57BL6/J male mice (n = 9-10/group). Three days after surgery, 6 groups of mice were treated as follows: 1) Vivarium Control (maintained continuously in standard cages); 2) Launch Negative Control (placed in the same spaceflight-like hardware as the Launch Positive Control group but were not subjected to launch simulation conditions); 3) Launch Positive Control (placed in spaceflight-like hardware and also subjected to vibration followed by centrifugation); 4) Launch Positive Experimental (identical to Launch Positive Control group, but placed in qualified spaceflight hardware); 5) Hindlimb Unloaded (HLU, were subjected to HLU immediately after launch simulation tests to simulate unloading in spaceflight); and 6) HLU Control (single housed in identical HLU cages but not suspended). Mice were euthanized 28 days after launch simulation and bone healing was examined via micro-Computed Tomography (μCT). These studies demonstrated that the mice post-surgery can tolerate launch conditions. Additionally, forces and vibrations associated with launch did not impact bone healing (p = .3). However, HLU resulted in a 52.5% reduction in total callus volume compared to HLU Controls (p = .0003). Taken together, these findings suggest that mice having a femoral SBD surgery tolerated the vibration and hypergravity associated with launch, and that launch simulation itself did not impact bone healing, but that the prolonged lack of weight bearing associated with HLU did impair bone healing. Based on these findings, we proceeded with testing the efficacy of FDA approved and novel SBD therapies using the unique spaceflight environment as a novel unloading model on SpaceX CRS-10.

  10. Bone Replacement Materials and Techniques Used for Achieving Vertical Alveolar Bone Augmentation

    PubMed Central

    Sheikh, Zeeshan; Sima, Corneliu; Glogauer, Michael

    2015-01-01

    Alveolar bone augmentation in vertical dimension remains the holy grail of periodontal tissue engineering. Successful dental implant placement for restoration of edentulous sites depends on the quality and quantity of alveolar bone available in all spatial dimensions. There are several surgical techniques used alone or in combination with natural or synthetic graft materials to achieve vertical alveolar bone augmentation. While continuously improving surgical techniques combined with the use of auto- or allografts provide the most predictable clinical outcomes, their success often depends on the status of recipient tissues. The morbidity associated with donor sites for auto-grafts makes these techniques less appealing to both patients and clinicians. New developments in material sciences offer a range of synthetic replacements for natural grafts to address the shortcoming of a second surgical site and relatively high resorption rates. This narrative review focuses on existing techniques, natural tissues and synthetic biomaterials commonly used to achieve vertical bone height gain in order to successfully restore edentulous ridges with implant-supported prostheses.

  11. Traumatic bone cyst suggestive of large apical periodontitis.

    PubMed

    Rodrigues, Cleomar Donizeth; Estrela, Carlos

    2008-04-01

    This case report shows the importance of establishing the correct diagnosis to provide the appropriate treatment options The traumatic bone cyst is a pseudocyst, usually asymptomatic and found by a routine radiographic examination. Unicystic radiolucency is almost always observed, which can involve the periradicular area of teeth, simulating an inflammatory lesion of endodontic origin. Differential diagnosis should include other pathologies, such as odontogenic keratocyst, central giant cell granuloma, and unicystic ameloblastoma. Its etiology and pathogenesis are not yet definitely established. In the present study, after review of the medical and dental histories and clinical and radiographic examination of teeth #24-27 (pulpal vitality test showed positive), the primary diagnosis was traumatic bone cyst. The planning was excisional biopsy. After surgical exploration, only one small blood clot was observed in the intraosseous socket, which was carefully curetted and filled with blood. A clinical and radiographic examination after 6 months showed apical formation and pulpal vitality preserved.

  12. Accuracy in planar cutting of bones: an ISO-based evaluation.

    PubMed

    Cartiaux, Olivier; Paul, Laurent; Docquier, Pierre-Louis; Francq, Bernard G; Raucent, Benoît; Dombre, Etienne; Banse, Xavier

    2009-03-01

    Computer- and robot-assisted technologies are capable of improving the accuracy of planar cutting in orthopaedic surgery. This study is a first step toward formulating and validating a new evaluation methodology for planar bone cutting, based on the standards from the International Organization for Standardization. Our experimental test bed consisted of a purely geometrical model of the cutting process around a simulated bone. Cuts were performed at three levels of surgical assistance: unassisted, computer-assisted and robot-assisted. We measured three parameters of the standard ISO1101:2004: flatness, parallelism and location of the cut plane. The location was the most relevant parameter for assessing cutting errors. The three levels of assistance were easily distinguished using the location parameter. Our ISO methodology employs the location to obtain all information about translational and rotational cutting errors. Location may be used on any osseous structure to compare the performance of existing assistance technologies.

  13. Computer-aided design/computer-aided manufacturing skull base drill.

    PubMed

    Couldwell, William T; MacDonald, Joel D; Thomas, Charles L; Hansen, Bradley C; Lapalikar, Aniruddha; Thakkar, Bharat; Balaji, Alagar K

    2017-05-01

    The authors have developed a simple device for computer-aided design/computer-aided manufacturing (CAD-CAM) that uses an image-guided system to define a cutting tool path that is shared with a surgical machining system for drilling bone. Information from 2D images (obtained via CT and MRI) is transmitted to a processor that produces a 3D image. The processor generates code defining an optimized cutting tool path, which is sent to a surgical machining system that can drill the desired portion of bone. This tool has applications for bone removal in both cranial and spine neurosurgical approaches. Such applications have the potential to reduce surgical time and associated complications such as infection or blood loss. The device enables rapid removal of bone within 1 mm of vital structures. The validity of such a machining tool is exemplified in the rapid (< 3 minutes machining time) and accurate removal of bone for transtemporal (for example, translabyrinthine) approaches.

  14. Relationship Between Bariatric Surgery and Bone Mineral Density: a Meta-analysis.

    PubMed

    Ko, Byung-Joon; Myung, Seung Kwon; Cho, Kyung-Hwan; Park, Yong Gyu; Kim, Sin Gon; Kim, Do Hoon; Kim, Seon Mee

    2016-07-01

    A meta-analysis regarding bone loss after bariatric surgery, designed to compare surgical and nonsurgical groups, has not yet been performed. Therefore, we performed a meta-analysis to compare the differences between bariatric surgical groups and nonoperated controls with regard to bone mineral density. In March 2015, we performed a review of the literature using PubMed, EMBASE, and the Cochrane Library. The search focused on retrospective and prospective studies, including but not limited to randomized studies published in English. Among 1299 studies that were initially screened, ten met the selection criteria. For all types of bariatric surgery, bone density at the femoral neck was lower in the surgical group than in the nonsurgical control group (mean difference [MD] -0.05 g/cm(2); 95 % confidence interval [CI], -0.07 to -0.02; p = 0.001); no difference in bone density was found between the two groups at the lumbar spine (MD -0.01 g/cm(2); 95 % CI -0.07 to 0.05; p = 0.661). The analysis of Roux-en-Y gastric bypass showed similar results. Bone density at the femoral neck decreased after bariatric surgery, compared to that in nonsurgical controls, whereas bone density at the lumbar spine did not show a difference between groups. Further larger scale studies with comparative nonsurgical controls are warranted to overcome the heterogeneity among studies in this analysis and to add evidence of possible bone loss subsequent to bariatric surgical procedures.

  15. Cognitive Load in Mastoidectomy Skills Training: Virtual Reality Simulation and Traditional Dissection Compared.

    PubMed

    Andersen, Steven Arild Wuyts; Mikkelsen, Peter Trier; Konge, Lars; Cayé-Thomasen, Per; Sørensen, Mads Sølvsten

    2016-01-01

    The cognitive load (CL) theoretical framework suggests that working memory is limited, which has implications for learning and skills acquisition. Complex learning situations such as surgical skills training can potentially induce a cognitive overload, inhibiting learning. This study aims to compare CL in traditional cadaveric dissection training and virtual reality (VR) simulation training of mastoidectomy. A prospective, crossover study. Participants performed cadaveric dissection before VR simulation of the procedure or vice versa. CL was estimated by secondary-task reaction time testing at baseline and during the procedure in both training modalities. The national Danish temporal bone course. A total of 40 novice otorhinolaryngology residents. Reaction time was increased by 20% in VR simulation training and 55% in cadaveric dissection training of mastoidectomy compared with baseline measurements. Traditional dissection training increased CL significantly more than VR simulation training (p < 0.001). VR simulation training imposed a lower CL than traditional cadaveric dissection training of mastoidectomy. Learning complex surgical skills can be a challenge for the novice and mastoidectomy skills training could potentially be optimized by employing VR simulation training first because of the lower CL. Traditional dissection training could then be used to supplement skills training after basic competencies have been acquired in the VR simulation. Copyright © 2015 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  16. Does virtual reality simulation have a role in training trauma and orthopaedic surgeons?

    PubMed

    Bartlett, J D; Lawrence, J E; Stewart, M E; Nakano, N; Khanduja, V

    2018-05-01

    Aims The aim of this study was to assess the current evidence relating to the benefits of virtual reality (VR) simulation in orthopaedic surgical training, and to identify areas of future research. Materials and Methods A literature search using the MEDLINE, Embase, and Google Scholar databases was performed. The results' titles, abstracts, and references were examined for relevance. Results A total of 31 articles published between 2004 and 2016 and relating to the objective validity and efficacy of specific virtual reality orthopaedic surgical simulators were identified. We found 18 studies demonstrating the construct validity of 16 different orthopaedic virtual reality simulators by comparing expert and novice performance. Eight studies have demonstrated skill acquisition on a simulator by showing improvements in performance with repeated use. A further five studies have demonstrated measurable improvements in operating theatre performance following a period of virtual reality simulator training. Conclusion The demonstration of 'real-world' benefits from the use of VR simulation in knee and shoulder arthroscopy is promising. However, evidence supporting its utility in other forms of orthopaedic surgery is lacking. Further studies of validity and utility should be combined with robust analyses of the cost efficiency of validated simulators to justify the financial investment required for their use in orthopaedic training. Cite this article: Bone Joint J 2018;100-B:559-65.

  17. Radiographic Assessment of Bone Formation Using rhBMP2 at Maxillary Periapical Surgical Defects: A Case Series

    PubMed Central

    Kumar, M. Hari; Vishalakshi, K.; Sabitha, H.

    2016-01-01

    Periapical cysts are the most common inflammatory odontogenic cysts arising from untreated dental caries with pulp necrosis and periapical infection. The choice of treatment is often influenced by various factors like size, extension of the lesion, proximity to vital structures, systemic condition and compliance of the patient too. The treatment protocol for management of periapical cysts is still under discussion and options vary from conservative treatment by means of endodontic technique to surgical treatment like decompression or a marsupialisation or even to enucleation. Large bony defect secondary to periapical surgery compromising the tooth integrity often requires bone graft to enhance bone formation and thus restoring function at the earliest. The present case series included 10 patients who had established periapical pathology secondary to history of trauma on upper anterior teeth as well patients with history of carious teeth with an apparent failure in root canal therapy. All ten patients were treated with cyst enucleation and apiceotomy along with 1.4cc Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge implantation at surgical defect. Radiographs and clinical examinations were done upto 3 months to evaluate healing. Radiographic and clinical assessments revealed bone regeneration and restoration of the maxillary surgical defects in all 10 patients. No evidence of graft failure was noted. The Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge carrier is thus proved to be a viable option for the treatment of maxillary periapical surgical defects. PMID:27190972

  18. Radiographic Assessment of Bone Formation Using rhBMP2 at Maxillary Periapical Surgical Defects: A Case Series.

    PubMed

    Kumar, M Siva; Kumar, M Hari; Vishalakshi, K; Sabitha, H

    2016-04-01

    Periapical cysts are the most common inflammatory odontogenic cysts arising from untreated dental caries with pulp necrosis and periapical infection. The choice of treatment is often influenced by various factors like size, extension of the lesion, proximity to vital structures, systemic condition and compliance of the patient too. The treatment protocol for management of periapical cysts is still under discussion and options vary from conservative treatment by means of endodontic technique to surgical treatment like decompression or a marsupialisation or even to enucleation. Large bony defect secondary to periapical surgery compromising the tooth integrity often requires bone graft to enhance bone formation and thus restoring function at the earliest. The present case series included 10 patients who had established periapical pathology secondary to history of trauma on upper anterior teeth as well patients with history of carious teeth with an apparent failure in root canal therapy. All ten patients were treated with cyst enucleation and apiceotomy along with 1.4cc Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge implantation at surgical defect. Radiographs and clinical examinations were done upto 3 months to evaluate healing. Radiographic and clinical assessments revealed bone regeneration and restoration of the maxillary surgical defects in all 10 patients. No evidence of graft failure was noted. The Recombinant Human Bone Morphogenetic Protein-2 soaked Absorbable Collagen Sponge carrier is thus proved to be a viable option for the treatment of maxillary periapical surgical defects.

  19. Quantitation of mandibular ramus volume as a source of bone grafting.

    PubMed

    Verdugo, Fernando; Simonian, Krikor; Smith McDonald, Roberto; Nowzari, Hessam

    2009-10-01

    When alveolar atrophy impairs dental implant placement, ridge augmentation using mandibular ramus graft may be considered. In live patients, however, an accurate calculation of the amount of bone that can be safely harvested from the ramus has not been reported. The use of a software program to perform these calculations can aid in preventing surgical complications. The aim of the present study was to intra-surgically quantify the volume of the ramus bone graft that can be safely harvested in live patients, and compare it to presurgical computerized tomographic calculations. The AutoCAD software program quantified ramus bone graft in 40 consecutive patients from computerized tomographies. Direct intra-surgical measurements were recorded thereafter and compared to software data (n = 10). In these 10 patients, the bone volume was also measured at the recipient sites 6 months post-sinus augmentation. The mandibular second and third molar areas provided the thickest cortical graft averaging 2.8 +/- 0.6 mm. The thinnest bone was immediately posterior to the third molar (1.9 +/- 0.3 mm). The volume of ramus bone graft measured by AutoCAD averaged 0.8 mL (standard deviation [SD] 0.2 mL, range: 0.4-1.2 mL). The volume of bone graft measured intra-surgically averaged 2.5 mL (SD 0.4 mL, range: 1.8-3.0 mL). The difference between the two measurement methods was significant (p < 0.001). The bone volume measured 6 months post-sinus augmentation averaged 2.2 mL (SD 0.4 mL, range: 1.6-2.8 mL) with a mean loss of 0.3 mL in volume. The mandibular second molar area provided the thickest cortical graft. A cortical plate of 2.8 mm in average at combined second and third molar areas provided 2.5 mL particulated volume. The use of a design software program can improve surgical treatment planning prior to ramus bone grafting. The AutoCAD software program did not overestimate the volume of bone that can be safely harvested from the mandibular ramus.

  20. Femur-mounted navigation system for the arthroscopic treatment of femoroacetabular impingement

    NASA Astrophysics Data System (ADS)

    Park, S. H.; Hwang, D. S.; Yoon, Y. S.

    2013-07-01

    Femoroacetabular impingement stems from an abnormal shape of the acetabulum and proximal femur. It is treated by resection of damaged soft tissue and by the shaping of bone to resemble normal features. The arthroscopic treatment of femoroacetabular impingement has many advantages, including minimal incisions, rapid recovery, and less pain. However, in some cases, revision is needed owing to the insufficient resection of damaged bone from a misreading of the surgical site. The limited view of arthroscopy is the major reason for the complications. In this research, a navigation method for the arthroscopic treatment of femoroacetabular impingement is developed. The proposed navigation system consists of femur attachable measurement device and user interface. The bone mounted measurement devices measure points on head-neck junction for registration and position of surgical instrument. User interface shows the three-dimensional model of patient's femur and surgical instrument position that is tracked by measurement device. Surgeon can know the three-dimensional anatomical structure of hip joint and surgical instrument position on surgical site using navigation system. Surface registration was used to obtain relation between patient's coordinate at the surgical site and coordinate of three-dimensional model of femur. In this research, we evaluated the proposed navigation system using plastic model bone. It is expected that the surgical tool tracking position accuracy will be less than 1 mm.

  1. Metabolic Bone Diseases and Total Hip Arthroplasty: Preventing Complications.

    PubMed

    Moya-Angeler, Joaquin; Lane, Joseph M; Rodriguez, Jose A

    2017-11-01

    Metabolic bone diseases are a diverse group of conditions characterized by abnormalities in calcium metabolism and/or bone cell physiology. These unbalanced processes can eventually lead to bony deformities and altered joint biomechanics, resulting in degenerative joint disease. Not infrequently, patients with metabolic bone diseases have restricting hip joint pain that ultimately necessitates hip arthroplasty. To minimize complications, the surgeon must consider the particular characteristics of these patients. The surgical and medical management of patients with metabolic bone diseases undergoing hip arthroplasty requires appropriate preoperative diagnosis, careful attention to the technical challenges of surgery, and strategies to maximize the long-term results of the surgical intervention, such as the use of bone anabolic and anticatabolic agents.

  2. Histological evaluation of the influence of magnetic field application in autogenous bone grafts in rats.

    PubMed

    Puricelli, Edela; Dutra, Nardier B; Ponzoni, Deise

    2009-01-11

    Bone grafts are widely used in oral and maxillofacial reconstruction. The influence of electromagnetic fields and magnets on the endogenous stimulation of target tissues has been investigated. This work aimed to assess the quality of bone healing in surgical cavities filled with autogenous bone grafts, under the influence of a permanent magnetic field produced by in vivo buried devices. Metal devices consisting of commercially pure martensitic stainless steel washers and titanium screws were employed. Thirty male Wistar rats were divided into 3 experimental and 3 control groups. A surgical bone cavity was produced on the right femur, and a bone graft was collected and placed in each hole. Two metallic washers, magnetized in the experimental group but not in the control group, were attached on the borders of the cavity. The animals were sacrificed on postoperative days 15, 45 and 60. The histological analysis of control and experimental samples showed adequate integration of the bone grafts, with intense bone neoformation. On days 45 and 60, a continued influence of the magnetic field on the surgical cavity and on the bone graft was observed in samples from the experimental group. The results showed intense bone neoformation in the experimental group as compared to control animals. The intense extra-cortical bone neoformation observed suggests that the osteoconductor condition of the graft may be more susceptible to stimulation, when submitted to a magnetic field.

  3. Surgical and Patient Factors Affecting Marginal Bone Levels Around Dental Implants: A Comprehensive Overview of Systematic Reviews.

    PubMed

    Ting, Miriam; Tenaglia, Matthew S; Jones, Gary H; Suzuki, Jon B

    2017-04-01

    The objective of this systematic review was to perform a comprehensive overview of systematic reviews and meta-analyses of surgical and patient factors affecting marginal bone loss around osseointegrated dental implants in humans. Electronic databases were searched for systematic reviews and meta-analyses published up to November 2015. Of the 41 articles selected, 11 evaluated implant factors, 10 evaluated patient factors, 19 evaluated surgical protocol-related factors, and one evaluated all three factors. The chosen studies were AMSTAR rated for quality. The following parameters have statistically significant effect on marginal bone loss: (1) marginal bone loss was significantly more in patients with periodontitis than in periodontally healthy patients; (2) significantly greater in generalized aggressive periodontitis patients compared with chronic periodontitis patients; (3) significantly less in alveolar socket preservation techniques; (4) significantly more in alveolar ridge augmentation sites; (5) significantly more in men than in women; (6) significantly more in smokers than in nonsmokers; and (7) smokers also have significantly more marginal bone loss in the maxilla than in the mandible. Knowledge of the surgical and patient factors that affect marginal bone loss can aid the clinician in making informed choices in selecting implant treatment options that will enhance the longevity and long-term success of their implant-supported cases.

  4. A hierarchy of computationally derived surgical and patient influences on metal on metal press-fit acetabular cup failure.

    PubMed

    Clarke, S G; Phillips, A T M; Bull, A M J; Cobb, J P

    2012-06-01

    The impact of anatomical variation and surgical error on excessive wear and loosening of the acetabular component of large diameter metal-on-metal hip arthroplasties was measured using a multi-factorial analysis through 112 different simulations. Each surgical scenario was subject to eight different daily loading activities using finite element analysis. Excessive wear appears to be predominantly dependent on cup orientation, with inclination error having a higher influence than version error, according to the study findings. Acetabular cup loosening, as inferred from initial implant stability, appears to depend predominantly on factors concerning the area of cup-bone contact, specifically the level of cup seating achieved and the individual patient's anatomy. The extent of press fit obtained at time of surgery did not appear to influence either mechanism of failure in this study. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Distal radius osteotomy with volar locking plates based on computer simulation.

    PubMed

    Miyake, Junichi; Murase, Tsuyoshi; Moritomo, Hisao; Sugamoto, Kazuomi; Yoshikawa, Hideki

    2011-06-01

    Corrective osteotomy using dorsal plates and structural bone graft usually has been used for treating symptomatic distal radius malunions. However, the procedure is technically demanding and requires an extensive dorsal approach. Residual deformity is a relatively frequent complication of this technique. We evaluated the clinical applicability of a three-dimensional osteotomy using computer-aided design and manufacturing techniques with volar locking plates for distal radius malunions. Ten patients with metaphyseal radius malunions were treated. Corrective osteotomy was simulated with the help of three-dimensional bone surface models created using CT data. We simulated the most appropriate screw holes in the deformed radius using computer-aided design data of a locking plate. During surgery, using a custom-made surgical template, we predrilled the screw holes as simulated. After osteotomy, plate fixation using predrilled screw holes enabled automatic reduction of the distal radial fragment. Autogenous iliac cancellous bone was grafted after plate fixation. The median volar tilt, radial inclination, and ulnar variance improved from -20°, 13°, and 6 mm, respectively, before surgery to 12°, 24°, and 1 mm, respectively, after surgery. The median wrist flexion improved from 33° before surgery to 60° after surgery. The median wrist extension was 70° before surgery and 65° after surgery. All patients experienced wrist pain before surgery, which disappeared or decreased after surgery. Surgeons can operate precisely and easily using this advanced technique. It is a new treatment option for malunion of distal radius fractures.

  6. Finite element modeling of acoustic wave propagation and energy deposition in bone during extracorporeal shock wave treatment

    NASA Astrophysics Data System (ADS)

    Wang, Xiaofeng; Matula, Thomas J.; Ma, Yong; Liu, Zheng; Tu, Juan; Guo, Xiasheng; Zhang, Dong

    2013-06-01

    It is well known that extracorporeal shock wave treatment is capable of providing a non-surgical and relatively pain free alternative treatment modality for patients suffering from musculoskeletal disorders but do not respond well to conservative treatments. The major objective of current work is to investigate how the shock wave (SW) field would change if a bony structure exists in the path of the acoustic wave. Here, a model of finite element method (FEM) was developed based on linear elasticity and acoustic propagation equations to examine SW propagation and deflection near a mimic musculoskeletal bone. High-speed photography experiments were performed to record cavitation bubbles generated in SW field with the presence of mimic bone. By comparing experimental and simulated results, the effectiveness of FEM model could be verified and strain energy distributions in the bone were also predicted according to numerical simulations. The results show that (1) the SW field will be deflected with the presence of bony structure and varying deflection angles can be observed as the bone shifted up in the z-direction relative to SW geometric focus (F2 focus); (2) SW deflection angels predicted by the FEM model agree well with experimental results obtained from high-speed photographs; and (3) temporal evolutions of strain energy distribution in the bone can also be evaluated based on FEM model, with varied vertical distance between F2 focus and intended target point on the bone surface. The present studies indicate that, by combining MRI/CT scans and FEM modeling work, it is possible to better understand SW propagation characteristics and energy deposition in musculoskeletal structure during extracorporeal shock wave treatment, which is important for standardizing the treatment dosage, optimizing treatment protocols, and even providing patient-specific treatment guidance in clinic.

  7. Non-vascularized iliac bone grafting for scaphoid nonunion with avascular necrosis.

    PubMed

    Kim, Jihyeung; Park, Jin Woo; Chung, Jeehyeok; Jeong Bae, Kee; Gong, Hyun Sik; Baek, Goo Hyun

    2018-01-01

    We present the surgical outcomes of non-vascularized bone grafting taken from the iliac crest in 24 patients with scaphoid nonunion and avascular necrosis. The Fisk-Fernandez technique was used in 11 patients, and cancellous bone grafting was used in 13 patients. Bony union was achieved in 22 of the 24 patients. Non-vascularized iliac bone grafting can be used for the surgical management of scaphoid nonunion with avascular necrosis. Although revascularization of the proximal fragment after surgery was not evaluated, bony union was confirmed in nearly all patients. IV.

  8. [Surgical Techniques for Patella Replacement in Cases of Deficient Bone Stock in Revision TKA].

    PubMed

    Ritschl, P; Machacek, F; Strehn, L; Kloiber, J

    2015-06-01

    The patella replacement in revision surgery is a challenge especially in cases of unsufficient bone stock. Depending on the extent of the bone defect, the following videos demonstrate different approaches: Video 1: bone sparing removal of the patella implant: onlay-type patella implants. Video 2: complete cortical bone rim of the patella, residual thickness between 6 to 10 mm: biconvex patella implant. Video 3 and 4: small defects of the cortical bone rim of the patella, residual thickness 1 to 5 mm (patella shell): gull-wing osteotomy, patella bone grafting techniques. Video 5: partial necrosis/defect of the patella shell with incomplete cortical bone rim: porous tantalum patella prosthesis. On account of the various surgical options for different bone defects of the patella, patellectomy and pure patelloplasty should be avoided to prevent functional shortcomings. Georg Thieme Verlag KG Stuttgart · New York.

  9. Toward Patient Specific Long Lasting Metallic Implants for Mandibular Segmental Defects

    NASA Astrophysics Data System (ADS)

    Shayesteh Moghaddam, Narges

    Mandibular defects may result from tumor resection, trauma, or inflammation. The goals of mandibular reconstruction surgeries are to restore mandible function and aesthetics. To this end, surgeons use a combination of bone grafts and metallic implants. These implants have drastically different mechanical properties than the surrounding bone. As a result, the stress distribution in the mandible changes after surgery. The long-term abnormal stress/strain distribution may lead to either graft failure due to bone resorption as a result of stress shielding, or hardware failure due to stress concentrations. During the healing period of six to nine months it is important that complete immobilization, bringing mandibular micro-motion down to the level of 200-500 mum during chewing, is achieved. After this period it is desired that bone undergo normal stress for long-term success of the treatment. Although current high stiffness fixation hardware accomplishes this immobilization during the healing period, the hardware continues to alter the normal stress-strain trajectory seen during chewing once the engrafted bone heals. Over the long-term, the immobilized and stress-shielded engrafted bone tends to resorb. On the other hand, hardware fracturing or/and screw loosening is observed as the stress is concentrated at certain locations on the hardware. Equally as important is the permanent loss of chewing power due to the altered stress-strain relationships. The first stage of this research is to study the problems encountered following a mandibular segmental defect reconstructive surgery. To this end, we constructed a finite element model of a healthy mandible, which includes cortical and cancellous bone, teeth (enamel and dentin components), and the periodontal ligament. Using this model, we studied a healthy adult mandible under maximum molar bite force for stress, strain, displacement, and reaction force distribution. For mandibular segmental defect reconstruction the current standard of care consists of the use of Surgical Grade 5 titanium also known as Ti-6Al-4V hardware and either a single or double fibula barrel vascularized bone graft. We expanded our model to simulate the effects of this surgery. The expanded model includes both single and double barrel fibular bone graft repair of a right M1-M3 containing section of the mandible, Ti-6Al-4V fixation hardware and screws. We found that the stiffness mismatch between the fixation hardware and the bone causes stress shielding on the host mandible and the bone graft, and stress concentration at the fixation hardware and screws. The simulations results show that while a double-barrel graft is preferred, in the long-term it does not create the optimal outcome due to the abnormal stress pattern. To improve the long-term outcome with metallic implants it is essential to recreate the normal stress pattern. To achieve this outcome we investigated the use of porous nitinol as a substitute for the currently used titanium hardware. While NiTi already has a lower stiffness than titanium, it is possible to add porosity to further reduce the stiffness to be closer to that of cortical bone. The ultimate goal is to create fixation hardware that has sufficient stiffness for immobilization while recreating the normal stress pattern in the bone. Using a finite element model of devices fabricated from Surgical Grade 5 titanium and NiTi, we have found that stiffness-tuned NiTi hardware with conventional geometries should result in recreation of normal stress-strain trajectories and better treatment outcome. Finally, to further improve the outcome, we suggest the use of a two-stage mechanism Bone Bandaid which supports both the immobilization/healing and regenerative phases of mandibular segmental defect treatment. This device is made of two materials. The stiff Ti-6Al-4V portion provides the support during the healing period and is disengaged afterwards. The second material is a NiTi wire-frame to facilitate normal stress distribution after the initial healing period. The titanium part of this fixation hardware is released following radiological verification that the surgical osteotomies have healed. The release procedure is performed under local anesthetic via a microsurgical tool. With the titanium fixation hardware no longer functional, the NiTi webbing would act as a superstructure, like a skin, to the underlying grafted cortical bone. This device facilitates stress transduction through the normal stress-strain trajectories, allows restoration of power, drives cortical bone remodeling and strengthening, provides long-term strength, and a good bone bed for dental implants. If bone chips are used, instead of single or double bone graft, the webbing is more likely to support the bone chips while they are being incorporated with the mandible. We have performed computer simulation to investigate the two stages of the operation of the device. Our FEA results indicate that the Bone Bandaid supports both the immobilization needed during healing and the distribution of stress through the engrafted bone once it has healed. (Abstract shortened by ProQuest.).

  10. Haptic feedback improves surgeons' user experience and fracture reduction in facial trauma simulation.

    PubMed

    Girod, Sabine; Schvartzman, Sara C; Gaudilliere, Dyani; Salisbury, Kenneth; Silva, Rebeka

    2016-01-01

    Computer-assisted surgical (CAS) planning tools are available for craniofacial surgery, but are usually based on computer-aided design (CAD) tools that lack the ability to detect the collision of virtual objects (i.e., fractured bone segments). We developed a CAS system featuring a sense of touch (haptic) that enables surgeons to physically interact with individual, patient-specific anatomy and immerse in a three-dimensional virtual environment. In this study, we evaluated initial user experience with our novel system compared to an existing CAD system. Ten surgery resident trainees received a brief verbal introduction to both the haptic and CAD systems. Users simulated mandibular fracture reduction in three clinical cases within a 15 min time limit for each system and completed a questionnaire to assess their subjective experience. We compared standard landmarks and linear and angular measurements between the simulated results and the actual surgical outcome and found that haptic simulation results were not significantly different from actual postoperative outcomes. In contrast, CAD results significantly differed from both the haptic simulation and actual postoperative results. In addition to enabling a more accurate fracture repair, the haptic system provided a better user experience than the CAD system in terms of intuitiveness and self-reported quality of repair.

  11. Development and validation of an artificial wetlab training system for the lumbar discectomy.

    PubMed

    Adermann, Jens; Geissler, Norman; Bernal, Luis E; Kotzsch, Susanne; Korb, Werner

    2014-09-01

    An initial research indicated that realistic haptic simulators with an adapted training concept are needed to enhance the training for spinal surgery. A cognitive task analysis (CTA) was performed to define a realistic and helpful scenario-based simulation. Based on the results a simulator for lumbar discectomy was developed. Additionally, a realistic training operating room was built for a pilot. The results were validated. The CTA showed a need for realistic scenario-based training in spine surgery. The developed simulator consists of synthetic bone structures, synthetic soft tissue and an advanced bleeding system. Due to the close interdisciplinary cooperation of surgeons between engineers and psychologists, the iterative multicentre validation showed that the simulator is visually and haptically realistic. The simulator offers integrated sensors for the evaluation of the traction being used and the compression during surgery. The participating surgeons in the pilot workshop rated the simulator and the training concept as very useful for the improvement of their surgical skills. In the context of the present work a precise definition for the simulator and training concept was developed. The additional implementation of sensors allows the objective evaluation of the surgical training by the trainer. Compared to other training simulators and concepts, the high degree of objectivity strengthens the acceptance of the feedback. The measured data of the nerve root tension and the compression of the dura can be used for intraoperative control and a detailed postoperative evaluation.

  12. Characterization of articular cartilage and subchondral bone changes in the rat anterior cruciate ligament transection and meniscectomized models of osteoarthritis.

    PubMed

    Hayami, Tadashi; Pickarski, Maureen; Zhuo, Ya; Wesolowski, Gregg A; Rodan, Gideon A; Duong, Le T

    2006-02-01

    Osteoarthritis (OA) is a chronic joint disease characterized by cartilage destruction, subchondral bone sclerosis, and osteophyte formation. Subchondral bone stiffness has been proposed to initiate and/or contribute to cartilage deterioration in OA. The purpose of this study was to characterize subchondral bone remodeling, cartilage damage, and osteophytosis during the disease progression in two models of surgically induced OA. Rat knee joints were subjected either to anterior cruciate ligament transection (ACLT) alone or in combination with resection of medial menisci (ACLT + MMx). Histopathological changes in the surgical joints were compared with sham at 1, 2, 4, 6, and 10 weeks post-surgery. Using a modified Mankin scoring system, we demonstrate that articular cartilage damage occurs within 2 weeks post-surgery in both surgical models. Detectable cartilage surface damage and proteoglycan loss were observed as early as 1 week post-surgery. These were followed by the increases in vascular invasion into cartilage, in loss of chondrocyte number and in cell clustering. Histomorphometric analysis revealed subchondral bone loss in both models within 2 weeks post-surgery followed by significant increases in subchondral bone volume relative to sham up to 10 weeks post-surgery. Incidence of osteophyte formation was optimally observed in ACLT joints at 10 weeks and in ACLT + MMx joints at 6 weeks post-surgery. In summary, the two surgically induced rat OA models share many characteristics seen in human and other animal models of OA, including progressive articular cartilage degradation, subchondral bone sclerosis, and osteophyte formation. Moreover, increased subchondral bone resorption is associated with early development of cartilage lesions, which precedes significant cartilage thinning and subchondral bone sclerosis. Together, these findings support a role for bone remodeling in OA pathogenesis and suggest that these rat models are suitable for evaluating bone resorption inhibitors as potential disease-modifying pharmaco-therapies.

  13. [Basic concept in computer assisted surgery].

    PubMed

    Merloz, Philippe; Wu, Hao

    2006-03-01

    To investigate application of medical digital imaging systems and computer technologies in orthopedics. The main computer-assisted surgery systems comprise the four following subcategories. (1) A collection and recording process for digital data on each patient, including preoperative images (CT scans, MRI, standard X-rays), intraoperative visualization (fluoroscopy, ultrasound), and intraoperative position and orientation of surgical instruments or bone sections (using 3D localises). Data merging based on the matching of preoperative imaging (CT scans, MRI, standard X-rays) and intraoperative visualization (anatomical landmarks, or bone surfaces digitized intraoperatively via 3D localiser; intraoperative ultrasound images processed for delineation of bone contours). (2) In cases where only intraoperative images are used for computer-assisted surgical navigation, the calibration of the intraoperative imaging system replaces the merged data system, which is then no longer necessary. (3) A system that provides aid in decision-making, so that the surgical approach is planned on basis of multimodal information: the interactive positioning of surgical instruments or bone sections transmitted via pre- or intraoperative images, display of elements to guide surgical navigation (direction, axis, orientation, length and diameter of a surgical instrument, impingement, etc. ). And (4) A system that monitors the surgical procedure, thereby ensuring that the optimal strategy defined at the preoperative stage is taken into account. It is possible that computer-assisted orthopedic surgery systems will enable surgeons to better assess the accuracy and reliability of the various operative techniques, an indispensable stage in the optimization of surgery.

  14. Histological evaluation of the influence of magnetic field application in autogenous bone grafts in rats

    PubMed Central

    Puricelli, Edela; Dutra, Nardier B; Ponzoni, Deise

    2009-01-01

    Background Bone grafts are widely used in oral and maxillofacial reconstruction. The influence of electromagnetic fields and magnets on the endogenous stimulation of target tissues has been investigated. This work aimed to assess the quality of bone healing in surgical cavities filled with autogenous bone grafts, under the influence of a permanent magnetic field produced by in vivo buried devices. Methods Metal devices consisting of commercially pure martensitic stainless steel washers and titanium screws were employed. Thirty male Wistar rats were divided into 3 experimental and 3 control groups. A surgical bone cavity was produced on the right femur, and a bone graft was collected and placed in each hole. Two metallic washers, magnetized in the experimental group but not in the control group, were attached on the borders of the cavity. Results The animals were sacrificed on postoperative days 15, 45 and 60. The histological analysis of control and experimental samples showed adequate integration of the bone grafts, with intense bone neoformation. On days 45 and 60, a continued influence of the magnetic field on the surgical cavity and on the bone graft was observed in samples from the experimental group. Conclusion The results showed intense bone neoformation in the experimental group as compared to control animals. The intense extra-cortical bone neoformation observed suggests that the osteoconductor condition of the graft may be more susceptible to stimulation, when submitted to a magnetic field. PMID:19134221

  15. Innovative real CSF leak simulation model for rhinology training: human cadaveric design.

    PubMed

    AlQahtani, Abdulaziz A; Albathi, Abeer A; Alhammad, Othman M; Alrabie, Abdulkarim S

    2018-04-01

    To study the feasibility of designing a human cadaveric simulation model of real CSF leak for rhinology training. The laboratory investigation took place at the surgical academic center of Prince Sultan Military Medical City between 2016 and 2017. Five heads of human cadaveric specimens were cannulated into the intradural space through two frontal bone holes. Fluorescein-dyed fluid was injected intracranialy, then endoscopic endonasal iatrogenic skull base defect was created with observation of fluid leak, followed by skull base reconstruction. The outcome measures included subjective assessment of integrity of the design, the ability of creating real CSF leak in multiple site of skull base and the possibility of watertight closure by various surgical techniques. The fluid filled the intradural space in all specimens without spontaneous leak from skull base or extra sinus areas. Successfully, we demonstrated fluid leak from all areas after iatrogenic defect in the cribriform plate, fovea ethmoidalis, planum sphenoidale sellar and clival regions. Watertight closure was achieved in all defects using different reconstruction techniques (overly, underlay and gasket seal closure). The design is simulating the real patient with CSF leak. It has potential in the learning process of acquiring and maintaining the surgical skills of skull base reconstruction before direct involvement of the patient. This model needs further evaluation and competence measurement as training tools in rhinology training.

  16. Wound healing of osteotomy defects prepared with piezo or conventional surgical instruments: a pilot study in rabbits.

    PubMed

    Ma, Li; Mattheos, Nikos; Sun, Yan; Liu, Xi Ling; Yip Chui, Ying; Lang, Niklaus Peter

    2015-08-01

    The aim of the present study was to evaluate and compare the wound-healing process following osteotomies performed with either conventional rotary burs or piezoelectric surgery in a rabbit model. Two types of osteotomy window defects of the nasal cavities were prepared on the nasal bone of 16 adult New Zealand white rabbits with either a conventional rotary bur or piezo surgery. The defects were covered with a resorbable membrane. Four animals were killed at 1, 2, 3, and 5 weeks after the surgical procedure, respectively. Histological and morphometric evaluations were performed to assess the volumetric density of various tissue components: the blood clot, vascularized structures, provisional matrix, osteoid, mineralized bone, bone debris, residual tissue, and old bone. Significantly more bone debris was found at 1 week in the conventionally-prepared defects compared to the piezo surgically-prepared defects. At 2 and 3 weeks, a newly-formed hard tissue bridge, mainly composed of woven bone, was seen; however, no statistically-significant differences were observed. At 5 weeks, the defects were completely filled with newly-formed bone. The defects prepared by piezo surgery showed a significantly decreased proportion of bone debris at 1 week, compared to conventional rotary bur defect. © 2014 Wiley Publishing Asia Pty Ltd.

  17. Rapid orthodontic treatment after the ridge-splitting technique--a combined surgical-orthodontic approach for implant site development: case report.

    PubMed

    Amato, Francesco; Mirabella, A Davide; Borlizzi, Diego

    2012-08-01

    This article presents a clinical case of bilateral partial edentulism in the posterior mandible with severe horizontal and moderate vertical bone atrophy. A new technique using rapid orthodontics after ridge splitting is presented. The split-crest technique was carried out using piezosurgical instruments in the first molar and second premolar areas to widen the bone crest and open a channel for tooth movement. Immediately after, orthodontic appliances were used to move the first premolars distally and the second molars mesially into the surgical site. The rationale was to facilitate and accelerate orthodontic movement of the teeth, which is otherwise difficult in a cortical knife-edged ridge. The bone defect was filled with the alveolar bone of the adjacent teeth that were moved into the surgically opened path. Adequate bone volume for implant placement was generated in the first premolar area. Implants were then inserted, and the patient was rehabilitated.

  18. Can we assess healing of surgically treated long bone fractures on radiograph?

    PubMed

    Perlepe, V; Omoumi, P; Larbi, A; Putineanu, D; Dubuc, J-E; Schubert, T; Vande Berg, B

    2018-06-01

    To determine the frequency and causes for limitations in the radiographic evaluation of surgically treated long bone fractures. Six readers separately scored 140 sets of antero-posterior (AP) and lateral radiographs of surgically treated long bone fractures, using a radiographic union score (RUS). We determined the rate of assessability of the fracture edges at each of the four cortical segments (n=560) seen tangentially on the two radiographs and the causes for non-assessability. The rate of feasibility of the RUS (more than two fracture edges assessable per fracture) was determined and compared according to different parameters. Fracture edges were visible in 71% to 81% of the 560 cortical segments. Metal hardware superimposition was the most frequent cause for non-assessability (79-95%). RUS values could be calculated in 58% to 75% of fractures. Scoring was statistically significantly less frequently calculable in plated (31-56%) than in nailed fractures (90-97%), in distal (47-61%) than in proximal (78-89%) bones and in upper (27-49%) than in lower (76-91%) limb bones (P≤0.01). The type of stabilization hardware is the main limiting factor in the radiographic assessment of surgically treated long bone fractures. Scoring was feasible in only 31% to 56% of plated fractures. Copyright © 2018 Société française de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  19. A virtual reality interface for pre-planning of surgical operations based on a customized model of the patient

    NASA Astrophysics Data System (ADS)

    Witkowski, Marcin; Lenar, Janusz; Sitnik, Robert; Verdonschot, Nico

    2012-03-01

    We present a human-computer interface that enables the operator to plan a surgical procedure on the musculoskeletal (MS) model of the patient's lower limbs, send the modified model to the bio-mechanical analysis module, and export the scenario parameters to the surgical navigation system. The interface provides the operator with tools for: importing customized MS model of the patient, cutting bones and manipulating/removal of bony fragments, repositioning muscle insertion points, muscle removal and placing implants. After planning the operator exports the modified MS model for bio-mechanical analysis of the functional outcome. If the simulation result is satisfactory the exported scenario data may be directly used during the actual surgery. The advantages of the developed interface are the possibility of installing it in various hardware configurations and coherent operation regardless of the devices used. The hardware configurations proposed to be used with the interface are: (a) a standard computer keyboard and mouse, and a 2-D display, (b) a touch screen as a single device for both input and output, or (c) a 3-D display and a haptic device for natural manipulation of 3-D objects. The interface may be utilized in two main fields. Experienced surgeons may use it to simulate their intervention plans and prepare input data for a surgical navigation system while student or novice surgeons can use it for simulating results of their hypothetical procedure. The interface has been developed in the TLEMsafe project (www.tlemsafe.eu) funded by the European Commission FP7 program.

  20. Oral Steroids (Steroid Pills and Syrups)

    MedlinePlus

    ... compressions, especially of the backbone and the hip Loss of blood supply to bones (aseptic necrosis) may cause severe bone pain and may require surgical correction Bones To prevent osteoporosis (loss of calcium in the bones), it is important ...

  1. Forces associated with launch into space do not impact bone fracture healing.

    PubMed

    Childress, Paul; Brinker, Alexander; Gong, Cynthia-May S; Harris, Jonathan; Olivos, David J; Rytlewski, Jeffrey D; Scofield, David C; Choi, Sungshin Y; Shirazi-Fard, Yasaman; McKinley, Todd O; Chu, Tien-Min G; Conley, Carolynn L; Chakraborty, Nabarun; Hammamieh, Rasha; Kacena, Melissa A

    2018-02-01

    Segmental bone defects (SBDs) secondary to trauma invariably result in a prolonged recovery with an extended period of limited weight bearing on the affected limb. Soldiers sustaining blast injuries and civilians sustaining high energy trauma typify such a clinical scenario. These patients frequently sustain composite injuries with SBDs in concert with extensive soft tissue damage. For soft tissue injury resolution and skeletal reconstruction a patient may experience limited weight bearing for upwards of 6 months. Many small animal investigations have evaluated interventions for SBDs. While providing foundational information regarding the treatment of bone defects, these models do not simulate limited weight bearing conditions after injury. For example, mice ambulate immediately following anesthetic recovery, and in most cases are normally ambulating within 1-3 days post-surgery. Thus, investigations that combine disuse with bone healing may better test novel bone healing strategies. To remove weight bearing, we have designed a SBD rodent healing study in microgravity (µG) on the International Space Station (ISS) for the Rodent Research-4 (RR-4) Mission, which launched February 19, 2017 on SpaceX CRS-10 (Commercial Resupply Services). In preparation for this mission, we conducted an end-to-end mission simulation consisting of surgical infliction of SBD followed by launch simulation and hindlimb unloading (HLU) studies. In brief, a 2 mm defect was created in the femur of 10 week-old C57BL6/J male mice (n = 9-10/group). Three days after surgery, 6 groups of mice were treated as follows: 1) Vivarium Control (maintained continuously in standard cages); 2) Launch Negative Control (placed in the same spaceflight-like hardware as the Launch Positive Control group but were not subjected to launch simulation conditions); 3) Launch Positive Control (placed in spaceflight-like hardware and also subjected to vibration followed by centrifugation); 4) Launch Positive Experimental (identical to Launch Positive Control group, but placed in qualified spaceflight hardware); 5) Hindlimb Unloaded (HLU, were subjected to HLU immediately after launch simulation tests to simulate unloading in spaceflight); and 6) HLU Control (single housed in identical HLU cages but not suspended). Mice were euthanized 28 days after launch simulation and bone healing was examined via micro-Computed Tomography (µCT). These studies demonstrated that the mice post-surgery can tolerate launch conditions. Additionally, forces and vibrations associated with launch did not impact bone healing (p = .3). However, HLU resulted in a 52.5% reduction in total callus volume compared to HLU Controls (p = .0003). Taken together, these findings suggest that mice having a femoral SBD surgery tolerated the vibration and hypergravity associated with launch, and that launch simulation itself did not impact bone healing, but that the prolonged lack of weight bearing associated with HLU did impair bone healing. Based on these findings, we proceeded with testing the efficacy of FDA approved and novel SBD therapies using the unique spaceflight environment as a novel unloading model on SpaceX CRS-10. Copyright © 2017 The Committee on Space Research (COSPAR). All rights reserved.

  2. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor.

    PubMed

    Panizza, Pedro Sergio Brito; de Albuquerque Cavalcanti, Conrado Furtado; Yamaguchi, Nise Hitomi; Leite, Claudia Costa; Cerri, Giovanni Guido; de Menezes, Marcos Roberto

    2016-02-01

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  3. Percutaneous CT-Guided Cryoablation as an Alternative Treatment for an Extensive Pelvic Bone Giant Cell Tumor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Panizza, Pedro Sergio Brito; Albuquerque Cavalcanti, Conrado Furtado de; Yamaguchi, Nise Hitomi

    2016-02-15

    A giant cell tumor (GCT) is an intermediate grade, locally aggressive neoplasia. Despite advances in surgical and clinical treatments, cases located on the spine and pelvic bones remain a significant challenge. Failure of clinical treatment with denosumab and patient refusal of surgical procedures (hemipelvectomy) led to the use of cryoablation. We report the use of percutaneous CT-guided cryoablation as an alternative treatment, shown to be a minimally invasive, safe, and effective option for a GCT with extensive involvement of the pelvic bones and allowed structural and functional preservation of the involved bones.

  4. Surgical Tip for Prevention of Lip Injury During Orthognathic and Facial Bone Contouring Surgery.

    PubMed

    Lee, Tae Sung; Park, Sanghoon

    2017-10-01

    Iatrogenic lip injury is a rather common complication after facial bone surgery, but is usually treated lightly by the surgeon compared with other more severe functional complications. However, these injuries can have permanent sequelae and can therefore be a reason for patient dissatisfaction, especially after cosmetic surgery. Intraoperative lip injuries during facial bone surgery are usually caused by heat-generating surgical instruments or forced traction on the operative fields. The authors have applied a special technical strategy using a hydrocolloid dressing material to avoid these intraoperative lip injuries. This method does not disturb the operative procedure itself, but efficiently prevents lip injuries and decreases surgical morbidities and postoperative swelling.

  5. Surgical harvesting of bone graft from the ilium: point of view.

    PubMed

    Russell, J L; Block, J E

    2000-12-01

    Autologous bone harvested from the ilium is commonly used as a grafting material in surgical reconstructive and arthrodesis procedures to ensure a satisfactory postoperative outcome. However, operative removal of bone from the iliac crest requires an additional surgical procedure with a distinct set of postoperative complications. We provide a comprehensive literature synthesis of the incidence and severity of complications reported to be associated with this commonly practiced procedure. Most severe complications are rare, but chronic pain at the donor site exceeding three months in duration occurs frequently and can be particularly bothersome to patients. Alternative grafting materials that are safe and effective are sorely needed. Copyright 2000 Harcourt Publishers Ltd.

  6. Fixation of Hydroxyapatite-Coated Revision Implants Is Improved by the Surgical Technique of Cracking the Sclerotic Bone Rim

    PubMed Central

    Elmengaard, Brian; Bechtold, Joan E.; Chen, Xinqian; Søballe, Kjeld

    2013-01-01

    Revision joint replacement has poorer outcomes that have been associated with poorer mechanical fixation. We investigate a new bone-sparing surgical technique that locally cracks the sclerotic bone rim formed during aseptic loosening. We inserted 16 hydroxyapatite-coated implants bilaterally in the distal femur of eight dogs, using a controlled weight-bearing experimental model that replicates important features of a typical revision setting. At 8 weeks, a control revision procedure and a crack revision procedure were performed on contralateral implants. The crack procedure used a splined tool to perform a systematic local perforation of the sclerotic bone rim of the revision cavity. After 4 weeks, the hydroxyapatite-coated implants were evaluated for mechanical fixation by a push-out test and for tissue distribution by histomorphometry. The cracking revision procedure resulted in significantly improved mechanical fixation, significantly more bone ongrowth and bone volume in the gap, and reduced fibrous tissue compared to the control revision procedure. The study demonstrates that the sclerotic bone rim prevents bone ingrowth and promotes fixation by fibrous tissue. The effect of the cracking technique may be due to improved access to the vascular compartment of the bone. The cracking technique is a simple surgical method that potentially can improve the fixation of revision implants in sclerotic regions important for obtaining the fixation critical for overall implant stability. PMID:19148940

  7. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  8. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  9. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  10. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  11. 21 CFR 872.4760 - Bone plate.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone plate. 872.4760 Section 872.4760 Food and... DENTAL DEVICES Surgical Devices § 872.4760 Bone plate. (a) Identification. A bone plate is a metal device intended to stabilize fractured bone structures in the oral cavity. The bone segments are attached to the...

  12. Fully customized placement of orthodontic miniplates: a novel clinical technique

    PubMed Central

    2014-01-01

    Introduction The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. Methods In order to apply this new technique, a cone-beam image of the insertion area is required. A software (Galaxy Sirona, Bensheim, Germany) is used to construct a three-dimensional image of the scanned area and to virtually determine the exact location of the mini-plate as well as the position of the fixation screws. A stereolithographic model (STL) is then created by means of a three-dimensional scanner. Prior to its surgical insertion, the bone plate is adapted to the stereo-lithographic model. Finally, a custom transfer jig is fabricated in order to assist with accurate placement of the mini-plate intra-operatively. Results The presented technique minimizes intra-operative decision making, because the final position of the bone plate is determined pre-surgically. This significantly reduces the duration of the surgical procedure and improves its outcome. Conclusions A novel method for surgical placement of orthodontic mini-plates is presented. The technique facilitates accurate adaptation of mini-plates and insertion of retaining surgical screws; thereby enabling clinicians to more confidently increase the use of bone plates, especially in anatomical areas where the success of non-osseointegrated mini-screws is less favorable. PMID:24886597

  13. Evaluation of primary and secondary stability of titanium implants using different surgical techniques.

    PubMed

    Tabassum, Afsheen; Meijer, Gert J; Walboomers, X Frank; Jansen, John A

    2014-04-01

    To investigate the influence of different surgical techniques on the primary and secondary implant stability using trabecular bone of goats as an implantation model. In the iliac crest of eight goats, 48 cylindrical-screw-type implants with a diameter of 4.2 mm (Dyna(®) ; Bergen op Zoom, the Netherlands) were installed, using three different surgical techniques: (i) 5% undersized, using a final drill diameter of 4 mm; (ii) 15% undersized, using a final drill diameter of 3.6 mm; and (iii) 25% undersized, using a final drill diameter of 3.2 mm. Peak insertion torque values were measured by a Digital(®) (MARK-10 Corporation, New York, NY, USA) torque gauge instrument during placement. At 3 weeks after implantation, removal torque was measured. Histomorphometrically, the peri-implant bone volume was measured in three zones; the inner zone (0-500 μm), the middle zone (500-1000 μm) and the outer zone (1000-1500 μm). Evaluation of the obtained data demonstrated no statistically significant difference between different surgical techniques regarding removal torque values. With respect to the percentage peri-implant bone volume (%BV), also no significant difference could be observed between all three applied surgical techniques for both the inner, middle and outer zone. However, irrespective of the surgical technique, it was noticed that the %BV was significantly higher for the inner zone as compared to middle and outer zone (P < 0.05) around the implant. At 3 weeks after implant installation, independent of the used undersized surgical technique, the %BV in the inner zone (0-500 μm) peri-implant area was improved due to both condensation of the surrounding bone as also the translocation of host bone particles along the implant surface. Surprisingly, no mechanical beneficial effect of the 25% undersized surgical technique could be observed as compared to the 5% or 15% undersized surgical technique to improve primary or secondary implant stability. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Corrective Septorhinoplasty in Acute Nasal Bone Fractures.

    PubMed

    Kim, Jisung; Jung, Hahn Jin; Shim, Woo Sub

    2018-03-01

    Closed reduction is generally recommended for acute nasal bone fractures, and rhinoplasty is considered in cases with an unsatisfactory outcome. However, concomitant rhinoplasty with fracture reduction might achieve better surgical outcomes. This study investigated the surgical techniques and outcomes in patients who underwent rhinoplasty and fracture reduction concomitantly, during the acute stage of nasal bone fracture. Forty-five patients who underwent concomitant rhinoplasty and fracture reduction were enrolled. Nasal bone fractures were classified into three major types (type I, simple fracture; type II, fracture line that mimics nasal osteotomy; and type III, comminuted fracture) based on computed tomography images and preoperative facial images. Two independent otolaryngology-head and neck surgeons evaluated the surgical outcomes and telephone based survey were made to evaluate patients satisfaction. Among 45 patients, there were 39 males and 6 females. Type I was the commonest type of fracture with 18 patients (40%), while the most frequently used surgical technique for corrective surgery was dorsal augmentation with 44 patients (97.8%). The mean visual analogue scale satisfaction score of the surgeons and patients were 7.62 and 8, respectively, with no significant differences between fracture types. Concomitant rhinoplasty with fracture reduction can be performed for acute nasal bone fracture patients, and it might lead to better aesthetic outcomes.

  15. Comprehensive surgical. Orthodontic treatment of class III malocclusion in cleft patient involving minimally invasive surgery Case report and literature review.

    PubMed

    Stojkovic, Goran; Stojkovic, Miodrag; Stojkovic, Jasna; Nikolic, Dejan; Stajcic, Zoran

    2016-12-19

    Surgical and orthodontic treatment of a teenage cleft patient. Authors describe the case of a 13 year old female cleft patient presented with class III malocclusion RESULT: The patient underwent comprehensive surgical secondary bone grafting and orthodontic treatment. Stable skeletal and occlusal class I relationship was achived and maintained in the post treatment observation period till the age of 16. Although several authors suggests primary gingivoperiosteoplasty, other advocates that such early intervention can cause later restrictions in maxillary growth. For alveolar reconstruction, maxillary growth and dental age were the main considerations in determining the timing of surgical intervention. This case showed that borderline cases of complex dentoalveolar and skeletal anomaly in cleft patients could be successfully treated with comprehensive secondary bone grafting and orthodontic treatment thus avoiding the need for orthognatic surgery. Alveolar bone grafting, Cleft, Malocclusion.

  16. Melorheostosis: a literature review and case report with surgical considerations.

    PubMed

    Gagliardi, Gabrielle Gellman; Mahan, Kieran T

    2010-01-01

    Melorheostosis is a rare disorder marked by increased bony sclerosis on radiographs. In addition to bone changes, the skin and soft tissues overlying affected bone often demonstrate increased fibrosis, which can create joint contracture. These can all affect surgical planning for a patient with melorheostosis. This article reviews the literature and describes the surgical intervention and 4-year follow-up of a 10-year-old boy with melorheostosis. Copyright 2010 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Bone Marrow Stem Cells Added to a Hydroxyapatite Scaffold Result in Better Outcomes after Surgical Treatment of Intertrochanteric Hip Fractures

    PubMed Central

    Gutierres, Manuel; Lopes, M. Ascenção; Santos, J. Domingos; Cabral, A. T.; Pinto, R.

    2014-01-01

    Introduction. Intertrochanteric hip fractures occur in the proximal femur. They are very common in the elderly and are responsible for high rates of morbidity and mortality. The authors hypothesized that adding an autologous bone marrow stem cells concentrate (ABMC) to a hydroxyapatite scaffold and placing it in the fracture site would improve the outcome after surgical fixation of intertrochanteric hip fractures. Material and Methods. 30 patients were randomly selected and divided into 2 groups of 15 patients, to receive either the scaffold enriched with the ABMC (Group A) during the surgical procedure, or fracture fixation alone (Group B). Results. There was a statistically significant difference in favor of group A at days 30, 60, and 90 for Harris Hip Scores (HHS), at days 30 and 60 for VAS pain scales, for bedridden period and time taken to start partial and total weight bearing (P < 0.05). Discussion. These results show a significant benefit of adding a bone marrow enriched scaffold to surgical fixation in intertrochanteric hip fractures, which can significantly reduce the associated morbidity and mortality rates. Conclusion. Bone marrow stem cells added to a hydroxyapatite scaffold result in better outcomes after surgical treatment of intertrochanteric hip fractures. PMID:24955356

  18. Surgical treatment of tumor-induced osteomalacia: a retrospective review of 40 cases with extremity tumors.

    PubMed

    Sun, Zhi-jian; Jin, Jin; Qiu, Gui-xing; Gao, Peng; Liu, Yong

    2015-02-26

    Tumor-induced osteomalacia (TIO) is a rare syndrome typically caused by mesenchymal tumors. It has been shown that complete tumor resection may be curative. However, to our knowledge, there has been no report of a large cohort to exam different surgical approaches. This study was aimed to assess outcomes of different surgical options of patients with tumor-induced osteomalacia at a single institution. Patients with extremity tumors treated in our hospital from January, 2004 to July, 2012 were identified. The minimum follow-up period was 12 months. Patient's demography, tumor location, preoperative preparation, type of surgeries were summarized, and clinical outcomes were recorded. Successful treatment was defined as significant symptom improvement, normal serum phosphorus and significant improvement or normalization of bone mineral density at the last follow-up. Differences between patients with soft tissue tumors and bone tumors were compared. There were 40 (24 male and 16 female) patients identified, with an average age of 44 years. The tumors were isolated in either soft tissue (25 patients) or bone (12 patients) and combined soft tissue and bone invasion was observed in 3 patients. For the primary surgery, tumor resection and tumor curettage were performed. After initial surgical treatment, six patients then received a second surgery. Four patients were found to have malignant tumors base on histopathology. With a minimum follow-up period of 12 months, 80% of patients (32/40) were treated successfully, including 50% of patients (2/4) with malignant tumors. Compared to patients with bone tumor, surgical results were better in patient with soft tissue tumor. Surgical treatment was an effective way for TIO. Other than tumor curettage surgery, tumor resection is the preferred options for these tumors.

  19. Rereduction for Redisplacement of Both-Bone Forearm Shaft Fractures in Children.

    PubMed

    Eismann, Emily A; Parikh, Shital N; Jain, Viral V

    2016-06-01

    There is a high rate of redisplacement after closed reduction and cast treatment of displaced both-bone forearm shaft fractures in children. Little evidence is available on the efficacy of rereduction of these redisplaced fractures. This study evaluates the impact of rereduction on radiographic outcomes and compares the cost to surgical stabilization. This retrospective study included 31 children (mean age, 6.3 y; 18 boys) treated with rereduction for redisplacement of a displaced both-bone forearm shaft fracture between 2008 and 2013. Angulation was measured on anteroposterior and lateral radiographs of the radius and ulna at injury, after reduction, at redisplacement, after rereduction, and at fracture union. Average procedure costs for rereduction and surgical stabilization were calculated. Initial reduction decreased apex volar angulation (initially >20 degrees) of both bones to a median of ≤2 degrees. After an average of 15 days (range, 4 to 35 d), apex volar angulation of the radius worsened to 9 degrees, and apex ulnar angulation worsened to >10 degrees for both bones. For every 5 days after initial reduction, apex ulnar angulation of the radius worsened by 4 degrees. Rereduction reduced apex ulnar and volar angulation of both bones to <5 degrees, which was maintained after cast removal. There were no complications. The average procedure cost for rereduction was $2056 compared with $4589 for surgical stabilization with or without implant removal. Rereduction of both-bone forearm shaft fractures after redisplacement following initial closed reduction had satisfactory radiographic outcomes and is a safe, effective, and less expensive option than surgical stabilization. Level IV-therapeutic.

  20. Minimally invasive esthetic ridge preservation with growth-factor enhanced bone matrix.

    PubMed

    Nevins, Marc L; Said, Sherif

    2017-12-28

    Extraction socket preservation procedures are critical to successful esthetic implant therapy. Conventional surgical approaches are technique sensitive and often result in alteration of the soft tissue architecture, which then requires additional corrective surgical procedures. This case series report presents the ability of flapless surgical techniques combined with a growth factor-enhanced bone matrix to provide esthetic ridge preservation at the time of extraction for compromised sockets. When considering esthetic dental implant therapy, preservation, or further enhancement of the available tissue support at the time of tooth extraction may provide an improved esthetic outcome with reduced postoperative sequelae and decreased treatment duration. Advances in minimally invasive surgical techniques combined with recombinant growth factor technology offer an alternative for bone reconstruction while maintaining the gingival architecture for enhanced esthetic outcome. The combination of freeze-dried bone allograft (FDBA) and rhPDGF-BB (platelet-derived growth factor-BB) provides a growth-factor enhanced matrix to induce bone and soft tissue healing. The use of a growth-factor enhanced matrix is an option for minimally invasive ridge preservation procedures for sites with advanced bone loss. Further studies including randomized clinical trials are needed to better understand the extent and limits of these procedures. The use of minimally invasive techniques with growth factors for esthetic ridge preservation reduces patient morbidity associated with more invasive approaches and increases the predictability for enhanced patient outcomes. By reducing the need for autogenous bone grafts the use of this technology is favorable for patient acceptance and ease of treatment process for esthetic dental implant therapy. © 2017 Wiley Periodicals, Inc.

  1. Geometric modeling of the temporal bone for cochlea implant simulation

    NASA Astrophysics Data System (ADS)

    Todd, Catherine A.; Naghdy, Fazel; O'Leary, Stephen

    2004-05-01

    The first stage in the development of a clinically valid surgical simulator for training otologic surgeons in performing cochlea implantation is presented. For this purpose, a geometric model of the temporal bone has been derived from a cadaver specimen using the biomedical image processing software package Analyze (AnalyzeDirect, Inc) and its three-dimensional reconstruction is examined. Simulator construction begins with registration and processing of a Computer Tomography (CT) medical image sequence. Important anatomical structures of the middle and inner ear are identified and segmented from each scan in a semi-automated threshold-based approach. Linear interpolation between image slices produces a three-dimensional volume dataset: the geometrical model. Artefacts are effectively eliminated using a semi-automatic seeded region-growing algorithm and unnecessary bony structures are removed. Once validated by an Ear, Nose and Throat (ENT) specialist, the model may be imported into the Reachin Application Programming Interface (API) (Reachin Technologies AB) for visual and haptic rendering associated with a virtual mastoidectomy. Interaction with the model is realized with haptics interfacing, providing the user with accurate torque and force feedback. Electrode array insertion into the cochlea will be introduced in the final stage of design.

  2. Development and Assessment of a 3D-Printed Scaffold with rhBMP-2 for an Implant Surgical Guide Stent and Bone Graft Material: A Pilot Animal Study.

    PubMed

    Bae, Ji Cheol; Lee, Jin-Ju; Shim, Jin-Hyung; Park, Keun-Ho; Lee, Jeong-Seok; Bae, Eun-Bin; Choi, Jae-Won; Huh, Jung-Bo

    2017-12-16

    In this study, a new concept of a 3D-printed scaffold was introduced for the accurate placement of an implant and the application of a recombinant human bone morphogenetic protein-2 (rhBMP-2)-loaded bone graft. This preliminary study was conducted using two adult beagles to evaluate the 3D-printed polycaprolactone (PCL)/ β -tricalcium phosphate ( β -TCP)/bone decellularized extracellular matrix (bdECM) scaffold conjugated with rhBMP-2 for the simultaneous use as an implant surgical guide stent and bone graft material that promotes new bone growth. Teeth were extracted from the mandible of the beagle model and scanned by computed tomography (CT) to fabricate a customized scaffold that would fit the bone defect. After positioning the implant guide scaffold, the implant was placed and rhBMP-2 was injected into the scaffold of the experimental group. The two beagles were sacrificed after three months. The specimen block was obtained and scanned by micro-CT. Histological analysis showed that the control and experimental groups had similar new bone volume (NBV, %) but the experimental group with BMP exhibited a significantly higher bone-to-implant contact ratio (BIC, %). Within the limitations of this preliminary study, a 3D-printed scaffold conjugated with rhBMP-2 can be used simultaneously as an implant surgical guide and a bone graft in a large bone defect site. Further large-scale studies will be needed to confirm these results.

  3. Reconstruction Of Glenoid Bone Deficiency With Porous Titanium Nickelide In Recurrent Anterior Shoulder Instability.

    PubMed

    Prokhorenko, Valery M; Fomenko, Sergey M; Filipenko, Pavel V; Turkov, Petr S

    2015-01-01

    One of the main causes of recurrent shoulder instability is a bone defect of the front edge of the glenoid. The available techniques for reconstruction of this bone defect, however, have some disadvantages. The aim of this study was to develop a new method that can reduce the number of postoperative complications and improve the efficiency of surgical treatment of recurrent anterior shoulder instability with glenoid bone defect. We present here a new method for surgical treatment of post-traumatic recurrent anterior shoulder instability with bony defects using porous NiTi. We operated 5 patients using this method. Computed tomography was used in the preoperative preparation of the NiTi graft. The graft was sawed from a cylindrical billet about 1 cm in thickness. Two screw holes were then made with a drill. The prepared graft was subsequently installed in the area of the glenoid bone defect. There were no recurrences of the dislocation after the surgical treatment. All patients returned to their previous levels of physical activity. The proposed method is an alternative to Latarjet procedure and iliac crest bone grafting. The advantages of this method are accurate reconstruction of the bone defect, minimal risk of recurrences, no resorption, and reduction of procedure time.

  4. Piezoelectric osteotomy for intraoral harvesting of bone blocks.

    PubMed

    Sohn, Dong-Seok; Ahn, Mi-Ra; Lee, Won-Hyuk; Yeo, Duk-Sung; Lim, So-Young

    2007-04-01

    Grafting with intraoral bone blocks is a good way to reconstruct severe horizontal and vertical bone resorption in future implant sites. The Piezosurgery System (Mectron) creates an effective osteotomy with minimal or no trauma to soft tissue, in contrast to conventional surgical burs or saws. In addition, piezoelectric surgery produces less vibration and noise because it uses microvibration, in contrast to the macrovibration and extreme noise that occur with a surgical saw or bur. Microvibration and reduced noise minimize a patient's psychologic stress and fear during osteotomy under local anesthesia. The purpose of this article is to describe the harvesting of intraoral bone blocks using the piezoelectric surgery device.

  5. Biodegradable fixation for craniomaxillofacial surgery: a 10-year experience involving 761 operations and 745 patients

    PubMed Central

    Turvey, T. A.; Proffit, W. P.; Phillips, C.

    2011-01-01

    Patient acceptance, safety, and efficacy of poly-L/DL-lactic acid (PLLDL) bone plates and screws in craniomaxillofacial surgery are reported in this article. Included in the sample are 745 patients who underwent 761 separate operations, including more than 1400 surgical procedures (orthognathic surgery (685), bone graft reconstruction (37), trauma (191) and transcranial surgery (20)). The success (no breakage or inflammation requiring additional operating room treatment) was 94%. Failure occurred because of breakage (14) or exuberant inflammation (31). All breakage occurred at mandibular sites and the majority of inflammatory failure occurred in the maxilla or orbit (29), with only two in the mandible. Failures were evenly distributed between the two major vendors. PLLDL 70/30 bone plates and screws may be used successfully in a variety of craniomaxillofacial surgical applications. The advantages include the gradual transference of physiological forces to the healing bone, the reduced need for a second operation to remove the material and its potential to serve as a vehicle to deliver bone-healing proteins to fracture/osteotomy sites. Bone healing was noted at all sites, even where exuberant inflammation required a second surgical intervention. PMID:21185695

  6. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    PubMed

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  7. Stress distribution of the foot during mid-stance to push-off in barefoot gait: a 3-D finite element analysis.

    PubMed

    Chen, W P; Tang, F T; Ju, C W

    2001-08-01

    To quantify stress distribution of the foot during mid-stance to push-off in barefoot gait using 3-D finite element analysis. To simulate the foot structure and facilitate later consideration of footwear. Finite element model was generated and loading condition simulating barefoot gait during mid-stance to push-off was used to quantify the stress distributions. A computational model can provide overall stress distributions of the foot subject to various loading conditions. A preliminary 3-D finite element foot model was generated based on the computed tomography data of a male subject and the bone and soft tissue structures were modeled. Analysis was performed for loading condition simulating barefoot gait during mid-stance to push-off. The peak plantar pressure ranged from 374 to 1003 kPa and the peak von Mises stress in the bone ranged from 2.12 to 6.91 MPa at different instants. The plantar pressure patterns were similar to measurement result from previous literature. The present study provides a preliminary computational model that is capable of estimating the overall plantar pressure and bone stress distributions. It can also provide quantitative analysis for normal and pathological foot motion. This model can identify areas of increased pressure and correlate the pressure with foot pathology. Potential applications can be found in the study of foot deformities, footwear, surgical interventions. It may assist pre-treatment planning, design of pedorthotic appliances, and predict the treatment effect of foot orthosis.

  8. Assessing Arthroscopic Skills Using Wireless Elbow-Worn Motion Sensors.

    PubMed

    Kirby, Georgina S J; Guyver, Paul; Strickland, Louise; Alvand, Abtin; Yang, Guang-Zhong; Hargrove, Caroline; Lo, Benny P L; Rees, Jonathan L

    2015-07-01

    Assessment of surgical skill is a critical component of surgical training. Approaches to assessment remain predominantly subjective, although more objective measures such as Global Rating Scales are in use. This study aimed to validate the use of elbow-worn, wireless, miniaturized motion sensors to assess the technical skill of trainees performing arthroscopic procedures in a simulated environment. Thirty participants were divided into three groups on the basis of their surgical experience: novices (n = 15), intermediates (n = 10), and experts (n = 5). All participants performed three standardized tasks on an arthroscopic virtual reality simulator while wearing wireless wrist and elbow motion sensors. Video output was recorded and a validated Global Rating Scale was used to assess performance; dexterity metrics were recorded from the simulator. Finally, live motion data were recorded via Bluetooth from the wireless wrist and elbow motion sensors and custom algorithms produced an arthroscopic performance score. Construct validity was demonstrated for all tasks, with Global Rating Scale scores and virtual reality output metrics showing significant differences between novices, intermediates, and experts (p < 0.001). The correlation of the virtual reality path length to the number of hand movements calculated from the wireless sensors was very high (p < 0.001). A comparison of the arthroscopic performance score levels with virtual reality output metrics also showed highly significant differences (p < 0.01). Comparisons of the arthroscopic performance score levels with the Global Rating Scale scores showed strong and highly significant correlations (p < 0.001) for both sensor locations, but those of the elbow-worn sensors were stronger and more significant (p < 0.001) than those of the wrist-worn sensors. A new wireless assessment of surgical performance system for objective assessment of surgical skills has proven valid for assessing arthroscopic skills. The elbow-worn sensors were shown to achieve an accurate assessment of surgical dexterity and performance. The validation of an entirely objective assessment of arthroscopic skill with wireless elbow-worn motion sensors introduces, for the first time, a feasible assessment system for the live operating theater with the added potential to be applied to other surgical and interventional specialties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  9. Utility of 3D printed temporal bones in pre-surgical planning for complex BoneBridge cases.

    PubMed

    Mukherjee, Payal; Cheng, Kai; Flanagan, Sean; Greenberg, Simon

    2017-08-01

    With the advent of single-sided hearing loss increasingly being treated with cochlear implantation, bone conduction implants are reserved for cases of conductive and mixed hearing loss with greater complexity. The BoneBridge (BB, MED-EL, Innsbruck, Austria) is an active fully implantable device with no attenuation of sound energy through soft tissue. However, the floating mass transducer (FMT) part of the device is very bulky, which limits insertion in complicated ears. In this study, 3D printed temporal bones of patients were used to study its utility in preoperative planning on complicated cases. Computed tomography (CT) scans of 16 ears were used to 3D print their temporal bones. Three otologists graded the use of routine preoperative planning provided by MED-EL and that of operating on the 3D printed bone of the patient. Data were collated to assess the advantage and disadvantage of the technology. There was a statistically significant benefit in using 3D printed temporal bones to plan surgery for difficult cases of BoneBridge surgery compared to the current standard. Surgeons preferred to have the printed bones in theatre to plan their drill sites and make the transition of the planning to the patient's operation more precise. 3D printing is an innovative use of technology in the use of preoperative planning for complex ear surgery. Surgical planning can be done on the patient's own anatomy which may help to decrease operating time, reduce cost, increase surgical precision and thus reduce complications.

  10. Quantifying bone thickness, light transmission, and contrast interrelationships in transcranial photoacoustic imaging

    NASA Astrophysics Data System (ADS)

    Lediju Bell, Muyinatu A.; Ostrowski, Anastasia K.; Li, Ke; Kaanzides, Peter; Boctor, Emad

    2015-03-01

    We previously introduced photoacoustic imaging to detect blood vessels surrounded by bone and thereby eliminate the deadly risk of carotid artery injury during endonasal, transsphenoidal surgeries. Light would be transmitted through an optical fiber attached to the surgical drill, while a transcranial probe placed on the temporal region of the skull receives photoacoustic signals. This work quantifies changes in photoacoustic image contrast as the sphenoid bone is drilled. Frontal bone from a human adult cadaver skull was cut into seven 3 cm x 3 cm chips and sanded to thicknesses ranging 1-4 mm. For 700-940 nm wavelengths, the average optical transmission through these specimens increased from 19% to 44% as bone thickness decreased, with measurements agreeing with Monte Carlo simulations within 5%. These skull specimens were individually placed in the optical pathway of a 3.5 mm diameter, cylindrical, vessel-mimicking photoacoustic target, as the laser wavelength was varied between 700-940 nm. The mean optical insertion loss and photoacoustic image contrast loss due to the bone specimens were 56-80% and 46-79%, respectively, with the majority of change observed when the bone was <=2 mm thick. The decrease in contrast is directly proportional to insertion loss over this thickness range by factors of 0.8-1.1 when multiple wavelengths are considered. Results suggest that this proportional relationship may be used to determine the amount of bone that remains to be drilled when the thickness is 2 mm or less.

  11. Biomechanical investigation of different surgical strategies for the treatment of rib fractures using a three-dimensional human respiratory model.

    PubMed

    Shih, Kao-Shang; Truong, Thanh An; Hsu, Ching-Chi; Hou, Sheng-Mou

    2017-11-02

    Rib fracture is a common injury and can result in pain during respiration. Conservative treatment of rib fracture is applied via mechanical ventilation. However, ventilator-associated complications frequently occur. Surgical fixation is another approach to treat rib fractures. Unfortunately, this surgical treatment is still not completely defined. Past studies have evaluated the biomechanics of the rib cage during respiration using a finite element method, but only intact conditions were modelled. Thus, the purpose of this study was to develop a realistic numerical model of the human rib cage and to analyse the biomechanical performance of intact, injured and treated rib cages. Three-dimensional finite element models of the human rib cage were developed. Respiratory movement of the human rib cage was simulated to evaluate the strengths and limitations of different scenarios. The results show that a realistic human respiratory movement can be simulated and the predicted results were closely related to previous study (correlation coefficient>0.92). Fixation of two fractured ribs significantly decreased the fixation index (191%) compared to the injured model. This fixation may provide adequate fixation stability as well as reveal lower bone stress and implant stress compared with the fixation of three or more fractured ribs.

  12. Graphite-reinforced bone cement

    NASA Technical Reports Server (NTRS)

    Knoell, A. C.

    1976-01-01

    Chopped graphite fibers added to surgical bone cement form bonding agent with mechanical properties closely matched to those of bone. Curing reaction produces less heat, resulting in reduced traumatization of body tissues. Stiffness is increased without affecting flexural strength.

  13. Computational Evaluation of Cochlear Implant Surgery Outcomes Accounting for Uncertainty and Parameter Variability.

    PubMed

    Mangado, Nerea; Pons-Prats, Jordi; Coma, Martí; Mistrík, Pavel; Piella, Gemma; Ceresa, Mario; González Ballester, Miguel Á

    2018-01-01

    Cochlear implantation (CI) is a complex surgical procedure that restores hearing in patients with severe deafness. The successful outcome of the implanted device relies on a group of factors, some of them unpredictable or difficult to control. Uncertainties on the electrode array position and the electrical properties of the bone make it difficult to accurately compute the current propagation delivered by the implant and the resulting neural activation. In this context, we use uncertainty quantification methods to explore how these uncertainties propagate through all the stages of CI computational simulations. To this end, we employ an automatic framework, encompassing from the finite element generation of CI models to the assessment of the neural response induced by the implant stimulation. To estimate the confidence intervals of the simulated neural response, we propose two approaches. First, we encode the variability of the cochlear morphology among the population through a statistical shape model. This allows us to generate a population of virtual patients using Monte Carlo sampling and to assign to each of them a set of parameter values according to a statistical distribution. The framework is implemented and parallelized in a High Throughput Computing environment that enables to maximize the available computing resources. Secondly, we perform a patient-specific study to evaluate the computed neural response to seek the optimal post-implantation stimulus levels. Considering a single cochlear morphology, the uncertainty in tissue electrical resistivity and surgical insertion parameters is propagated using the Probabilistic Collocation method, which reduces the number of samples to evaluate. Results show that bone resistivity has the highest influence on CI outcomes. In conjunction with the variability of the cochlear length, worst outcomes are obtained for small cochleae with high resistivity values. However, the effect of the surgical insertion length on the CI outcomes could not be clearly observed, since its impact may be concealed by the other considered parameters. Whereas the Monte Carlo approach implies a high computational cost, Probabilistic Collocation presents a suitable trade-off between precision and computational time. Results suggest that the proposed framework has a great potential to help in both surgical planning decisions and in the audiological setting process.

  14. Novel microinjector for carrying bone substitutes for bone regeneration in periodontal diseases.

    PubMed

    Tsai, Hsiao-Cheng; Li, Yi-Chen; Young, Tai-Horng; Chen, Min-Huey

    2016-01-01

    Traditionally, guide bone regeneration (GBR) was a widely used method for repairing bone lost from periodontal disease. There were some disadvantages associated with the GBR method, such as the need for a stable barrier membrane and a new creative cavity during the surgical process. To address these disadvantages, the purpose of this study was to evaluate a novel microinjector developed for dental applications. The microinjector was designed to carry bone graft substitutes to restore bone defects for bone regeneration in periodontal diseases. The device would be used to replace the GBR method. In this study, the injected force and ejected volume of substitutes (including air, water, and ethanol) were defined by Hooke's law (n = 3). The optimal particle size of bone graft substitutes was determined by measuring the recycle ratio of bone graft substitutes from the microinjector (n = 3). Furthermore, a novel agarose gel model was used to evaluate the feasibility of the microinjector. The current study found that the injected force was less than 0.4 N for obtaining the ejected volume of approximately 2 mL, and when the particle size of tricalcium phosphate (TCP) was smaller than 0.5 mm, 80% TCP could be ejected from the microinjector. Furthermore, by using an agarose model to simulate the periodontal soft tissue, it was also found that bone graft substitutes could be easily injected into the gel. The results confirmed the feasibility of this novel microinjector for dental applications to carry bone graft substitutes for the restoration of bone defects of periodontal disease. Copyright © 2015. Published by Elsevier B.V.

  15. Bilateral diaphyseal bone cysts of the tibia mimicking shin splints in a young professional athlete--a case report and depiction of a less-invasive surgical technique.

    PubMed

    Toepfer, Andreas; Harrasser, Norbert; Lenze, Ulrich; Liska, Franz; Mühlhofer, Heinrich; von Eisenhart-Rothe, Rüdiger; Banke, Ingo J

    2015-08-23

    Medial tibial stress syndrome is one of the most common causes of exertional leg pain in runners whereas musculoskeletal tumors and tumor-like lesions are rare encounters in orthopedic sports medicine practice. Unicameral (simple) bone cyst is a well-known tumor-like lesions of the bone typically affecting children and adolescents. Bilateral occurrence is very rare though and has never been reported before in both tibiae. Failing to accurately diagnose a tumorous lesion can entail far-reaching consequences for both patients and physicians. We report the case of large bilateral unicameral bone cysts of the diaphyseal tibiae mimicking medial tibial stress syndrome in a 17-year old professional athlete. This is the first report of symmetric tibial unicameral bone cysts in the literature. The patient complained about persisting shin splint-like symptoms over 5 months despite comprehensive conservative treatment before MRI revealed extensive osteolytic bone lesions in both diaphyseal tibiae. The patient-tailored, less-invasive surgical procedure, allowing the patient to return to his competitive sports level symptom-free 3 months after surgery and to eventually qualify for this years Biathlon Junior World Championships, is outlined briefly. Pathogenesis and various treatment options for this entity will be discussed. This report will help to raise awareness for musculoskeletal tumors as differential diagnosis for therapy-refractory symptoms in young athletes and encourage medical staff involved in sports medicine and athlete support to perform early high quality imaging and initiate sufficient surgical treatment in similar cases. Moreover, our less-invasive surgical procedure aiming for a fast return to sports might be an optimal compromise between traditional open curettage with low risk of recurrence and a soft tissue-saving and bone-sparing minimal-invasive technique.

  16. Laser vs bur for bone cutting in impacted mandibular third molar surgery: A randomized controlled trial.

    PubMed

    Passi, Deepak; Pal, Uma Shankar; Mohammad, Shadab; Singh, Rakesh Kumar; Mehrotra, Divya; Singh, Geeta; Kumar, Manoj; Chellappa, Arul A L; Gupta, Chandan

    2013-01-01

    The aim of this study was to assess the feasibility of Er: YAG laser in bone cutting for removal of impacted lower third molar teeth and compare its outcomes with that of surgical bur. The study comprised 40 subjects requiring removal of impacted mandibular third molar, randomly categorized into two equal groups of 20 each, who had their impacted third molar removed either using Er: YAG laser or surgical bur as per their group, using standard methodology of extraction of impacted teeth. Clinical parameters like pain, bleeding, time taken for bone cutting, postoperative swelling, trismus, wound healing and complications were compared for both groups. Clinical parameters like pain, bleeding and swelling were lower in laser group than bur group, although the difference was statistically not significant. However, postoperative swelling showed significant difference in the two groups. Laser group required almost double the time taken for bone cutting with bur. Trismus persisted for a longer period in laser group. Wound healing and complications were assessed clinically and there was no significant difference in both the groups. Based on the results of our study, the possibility of bone cutting using lasers is pursued, the osteotomy is easily performed and the technique is better suited to minimally invasive surgical procedures. The use of Er: YAG laser may be considered as an alternative tool to surgical bur, specially in anxious patients.

  17. [Intra-osseous ganglion cyst of the carpal bones. A review of the literature underlining the importance of systematic computed tomography].

    PubMed

    Dumas, P; Georgiou, C; Chignon-Sicard, B; Balaguer, T; Lebreton, E; Dumontier, C

    2013-02-01

    The intraosseous ganglion cyst (IOGC) is a benign and lytic bone tumor affecting mostly the metaphyseal and epiphyseal regions of long bones. Its location on the short bones, including the carpal bones has been little reported in the literature. Our review of the literature shows consensus about the surgical techniques to use, but there is currently no real consensus about its pathophysiology, and its diagnostic work-up. Complications related to this lesion (mainly the risk of pathologic fracture) are potentially serious, and can cause irreversible damage. They therefore require accurate assessment to guide the choice of medical or surgical treatment, including a CT scan, which - we believe - is essential. Copyright © 2012. Published by Elsevier SAS.

  18. "Direct DICOM Slice Landmarking" A Novel Research Technique to Quantify Skeletal Changes in Orthognathic Surgery.

    PubMed

    Almukhtar, Anas; Khambay, Balvinder; Ayoub, Ashraf; Ju, Xiangyang; Al-Hiyali, Ali; Macdonald, James; Jabar, Norhayati; Goto, Tazuko

    2015-01-01

    The limitations of the current methods of quantifying the surgical movements of facial bones inspired this study. The aim of this study was the assessment of the accuracy and reproducibility of directly landmarking of 3D DICOM images (Digital Imaging and Communications in Medicine) to quantify the changes in the jaw bones following surgery. The study was carried out on plastic skull to simulate the surgical movements of the jaw bones. Cone beam CT scans were taken at 3mm, 6mm, and 9mm maxillary advancement; together with a 2mm, 4mm, 6mm and 8mm "down graft" which in total generated 12 different positions of the maxilla for the analysis. The movements of the maxilla were calculated using two methods, the standard approach where distances between surface landmarks on the jaw bones were measured and the novel approach where measurements were taken directly from the internal structures of the corresponding 3D DICOME slices. A one sample t-test showed that there was no statistically significant difference between the two methods of measurements for the y and z directions, however, the x direction showed a significant difference. The mean difference between the two absolute measurements were 0.34±0.20mm, 0.22±0.16mm, 0.18±0.13mm in the y, z and x directions respectively. In conclusion, the direct landmarking of 3D DICOM image slices is a reliable, reproducible and informative method for assessment of the 3D skeletal changes. The method has a clear clinical application which includes the analysis of the jaw movements "orthognathic surgery" for the correction of facial deformities.

  19. Interactive computer simulations of knee-replacement surgery.

    PubMed

    Gunther, Stephen B; Soto, Gabriel E; Colman, William W

    2002-07-01

    Current surgical training programs in the United States are based on an apprenticeship model. This model is outdated because it does not provide conceptual scaffolding, promote collaborative learning, or offer constructive reinforcement. Our objective was to create a more useful approach by preparing students and residents for operative cases using interactive computer simulations of surgery. Total-knee-replacement surgery (TKR) is an ideal procedure to model on the computer because there is a systematic protocol for the procedure. Also, this protocol is difficult to learn by the apprenticeship model because of the multiple instruments that must be used in a specific order. We designed an interactive computer tutorial to teach medical students and residents how to perform knee-replacement surgery. We also aimed to reinforce the specific protocol of the operative procedure. Our final goal was to provide immediate, constructive feedback. We created a computer tutorial by generating three-dimensional wire-frame models of the surgical instruments. Next, we applied a surface to the wire-frame models using three-dimensional modeling. Finally, the three-dimensional models were animated to simulate the motions of an actual TKR. The tutorial is a step-by-step tutorial that teaches and tests the correct sequence of steps in a TKR. The student or resident must select the correct instruments in the correct order. The learner is encouraged to learn the stepwise surgical protocol through repetitive use of the computer simulation. Constructive feedback is acquired through a grading system, which rates the student's or resident's ability to perform the task in the correct order. The grading system also accounts for the time required to perform the simulated procedure. We evaluated the efficacy of this teaching technique by testing medical students who learned by the computer simulation and those who learned by reading the surgical protocol manual. Both groups then performed TKR on manufactured bone models using real instruments. Their technique was graded with the standard protocol. The students who learned on the computer simulation performed the task in a shorter time and with fewer errors than the control group. They were also more engaged in the learning process. Surgical training programs generally lack a consistent approach to preoperative education related to surgical procedures. This interactive computer tutorial has allowed us to make a quantum leap in medical student and resident teaching in our orthopedic department because the students actually participate in the entire process. Our technique provides a linear, sequential method of skill acquisition and direct feedback, which is ideally suited for learning stepwise surgical protocols. Since our initial evaluation has shown the efficacy of this program, we have implemented this teaching tool into our orthopedic curriculum. Our plans for future work with this simulator include modeling procedures involving other anatomic areas of interest, such as the hip and shoulder.

  20. Surgical and Technical Modalities for Hearing Restoration in Ear Malformations.

    PubMed

    Dazert, Stefan; Thomas, Jan Peter; Volkenstein, Stefan

    2015-12-01

    Malformations of the external and middle ear often go along with an aesthetic and functional handicap. Independent of additional aesthetic procedures, a successful functional hearing restoration leads to a tremendous gain in quality of life for affected patients. The introduction of implantable hearing systems (bone conduction and middle ear devices) offers new therapeutic options in this field. We focus on functional rehabilitation of patients with malformations, either by surgical reconstruction or the use of different implantable hearing devices, depending on the disease itself and the severity of malformation as well as hearing impairment. Patients with an open ear canal and minor malformations are good candidates for surgical hearing restoration of middle ear structures with passive titanium or autologous implants. In cases with complete fibrous or bony atresia of the ear canal, the most promising functional outcome and gain in quality of life can be expected with an active middle ear implant or a bone conduction device combined with a surgical aesthetic rehabilitation in a single or multi-step procedure. Although the surgical procedure for bone conduction devices is straightforward and safe, more sophisticated operations for active middle ear implants (e.g., Vibrant Soundbridge, MED-EL, Innsbruck, Austria) provide an improved speech discrimination in noise and the ability of sound localization compared with bone conduction devices where the stimulation reaches both cochleae. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  1. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  2. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  3. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  4. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  5. 21 CFR 872.4120 - Bone cutting instrument and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone cutting instrument and accessories. 872.4120... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Surgical Devices § 872.4120 Bone cutting instrument and accessories. (a) Identification. A bone cutting instrument and accessories is a metal device intended for use...

  6. Computational modeling to predict mechanical function of joints: application to the lower leg with simulation of two cadaver studies.

    PubMed

    Liacouras, Peter C; Wayne, Jennifer S

    2007-12-01

    Computational models of musculoskeletal joints and limbs can provide useful information about joint mechanics. Validated models can be used as predictive devices for understanding joint function and serve as clinical tools for predicting the outcome of surgical procedures. A new computational modeling approach was developed for simulating joint kinematics that are dictated by bone/joint anatomy, ligamentous constraints, and applied loading. Three-dimensional computational models of the lower leg were created to illustrate the application of this new approach. Model development began with generating three-dimensional surfaces of each bone from CT images and then importing into the three-dimensional solid modeling software SOLIDWORKS and motion simulation package COSMOSMOTION. Through SOLIDWORKS and COSMOSMOTION, each bone surface file was filled to create a solid object and positioned necessary components added, and simulations executed. Three-dimensional contacts were added to inhibit intersection of the bones during motion. Ligaments were represented as linear springs. Model predictions were then validated by comparison to two different cadaver studies, syndesmotic injury and repair and ankle inversion following ligament transection. The syndesmotic injury model was able to predict tibial rotation, fibular rotation, and anterior/posterior displacement. In the inversion simulation, calcaneofibular ligament extension and angles of inversion compared well. Some experimental data proved harder to simulate accurately, due to certain software limitations and lack of complete experimental data. Other parameters that could not be easily obtained experimentally can be predicted and analyzed by the computational simulations. In the syndesmotic injury study, the force generated in the tibionavicular and calcaneofibular ligaments reduced with the insertion of the staple, indicating how this repair technique changes joint function. After transection of the calcaneofibular ligament in the inversion stability study, a major increase in force was seen in several of the ligaments on the lateral aspect of the foot and ankle, indicating the recruitment of other structures to permit function after injury. Overall, the computational models were able to predict joint kinematics of the lower leg with particular focus on the ankle complex. This same approach can be taken to create models of other limb segments such as the elbow and wrist. Additional parameters can be calculated in the models that are not easily obtained experimentally such as ligament forces, force transmission across joints, and three-dimensional movement of all bones. Muscle activation can be incorporated in the model through the action of applied forces within the software for future studies.

  7. Chitosan nanofiber scaffold improves bone healing via stimulating trabecular bone production due to upregulation of the Runx2/osteocalcin/alkaline phosphatase signaling pathway

    PubMed Central

    Ho, Ming-Hua; Yao, Chih-Jung; Liao, Mei-Hsiu; Lin, Pei-I; Liu, Shing-Hwa; Chen, Ruei-Ming

    2015-01-01

    Osteoblasts play critical roles in bone formation. Our previous study showed that chitosan nanofibers can stimulate osteoblast proliferation and maturation. This translational study used an animal model of bone defects to evaluate the effects of chitosan nanofiber scaffolds on bone healing and the possible mechanisms. In this study, we produced uniform chitosan nanofibers with fiber diameters of approximately 200 nm. A bone defect was surgically created in the proximal femurs of male C57LB/6 mice, and then the left femur was implanted with chitosan nanofiber scaffolds for 21 days and compared with the right femur, which served as a control. Histological analyses revealed that implantation of chitosan nanofiber scaffolds did not lead to hepatotoxicity or nephrotoxicity. Instead, imaging analyses by X-ray transmission and microcomputed tomography showed that implantation of chitosan nanofiber scaffolds improved bone healing compared with the control group. In parallel, microcomputed tomography and bone histomorphometric assays further demonstrated augmentation of the production of new trabecular bone in the chitosan nanofiber-treated group. Furthermore, implantation of chitosan nanofiber scaffolds led to a significant increase in the trabecular bone thickness but a reduction in the trabecular parameter factor. As to the mechanisms, analysis by confocal microscopy showed that implantation of chitosan nanofiber scaffolds increased levels of Runt-related transcription factor 2 (Runx2), a key transcription factor that regulates osteogenesis, in the bone defect sites. Successively, amounts of alkaline phosphatase and osteocalcin, two typical biomarkers that can simulate bone maturation, were augmented following implantation of chitosan nanofiber scaffolds. Taken together, this translational study showed a beneficial effect of chitosan nanofiber scaffolds on bone healing through stimulating trabecular bone production due to upregulation of Runx2-mediated alkaline phosphatase and osteocalcin gene expressions. Our results suggest the potential of chitosan nanofiber scaffolds for therapy of bone diseases, including bone defects and bone fractures. PMID:26451104

  8. Microsurgical and Endoscopic Anatomy for Intradural Temporal Bone Drilling and Applications of the Electromagnetic Navigation System: Various Extensions of the Retrosigmoid Approach.

    PubMed

    Matsushima, Ken; Komune, Noritaka; Matsuo, Satoshi; Kohno, Michihiro

    2017-07-01

    The use of the retrosigmoid approach has recently been expanded by several modifications, including the suprameatal, transmeatal, suprajugular, and inframeatal extensions. Intradural temporal bone drilling without damaging vital structures inside or beside the bone, such as the internal carotid artery and jugular bulb, is a key step for these extensions. This study aimed to examine the microsurgical and endoscopic anatomy of the extensions of the retrosigmoid approach and to evaluate the clinical feasibility of an electromagnetic navigation system during intradural temporal bone drilling. Five temporal bones and 8 cadaveric cerebellopontine angles were examined to clarify the anatomy of retrosigmoid intradural temporal bone drilling. Twenty additional cerebellopontine angles were dissected in a clinical setting with an electromagnetic navigation system while measuring the target registration errors at 8 surgical landmarks on and inside the temporal bone. Retrosigmoid intradural temporal bone drilling expanded the surgical exposure to allow access to the petroclival and parasellar regions (suprameatal), internal acoustic meatus (transmeatal), upper jugular foramen (suprajugular), and petrous apex (inframeatal). The electromagnetic navigation continuously guided the drilling without line of sight limitation, and its small devices were easily manipulated in the deep and narrow surgical field in the posterior fossa. Mean target registration error was less than 0.50 mm during these procedures. The combination of endoscopic and microsurgical techniques aids in achieving optimal exposure for retrosigmoid intradural temporal bone drilling. The electromagnetic navigation system had clear advantages with acceptable accuracy including the usability of small devices without line of sight limitation. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Maxillary reconstruction with bone transport distraction and implants after partial maxillectomy.

    PubMed

    Castro-Núñez, Jaime; González, Marcos Daniel

    2013-02-01

    Maxillary and mandibular bone defects can result from injury, congenital defect, or accident, or as a consequence of surgical procedures when treating pathology or defects affecting jaw bones. The glandular odontogenic cyst is an infrequent type of odontogenic cyst that can leave a bony defect after being treated by aggressive surgical means. First described in 1987 by Padayachee and Van Wyk, it is a potentially aggressive entity, having a predisposition to recur when treated conservatively, with only 111 cases having been reported hitherto. Most reports emphasize its clinical, radiographic, and histologic features, including a few considerations on rehabilitation for these patients. The aim of this article is to present the case of a 24-year-old male patient who, in 2001, was diagnosed with a glandular odontogenic cyst and to focus on the surgical approach and rehabilitation scheme. We performed an anterior partial maxillectomy. The osseous defect was treated using bone transport distraction. Dental and occlusal rehabilitation was achieved with titanium implants over transported bone and an implant-supported overdenture. A 9-year follow-up shows no evidence of recurrence of the pathology, adequate shape and amount of bone, functional occlusal and dental rehabilitation, and patient's satisfaction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Comparison of Er:YAG laser and surgical drill for osteotomy in oral surgery: an experimental study.

    PubMed

    Gabrić Pandurić, Dragana; Bago, Ivona; Katanec, Davor; Zabkar, Janez; Miletić, Ivana; Anić, Ivica

    2012-11-01

    High-energy lasers have been proposed as an alternative to the conventional surgical drill in oral and maxillofacial surgery. The aims of this study were to compare thermal changes of the bone surface, procedure time, and volume of the removed bone after drilling with an erbium (Er):yttrium-aluminum-garnet (YAG) laser versus a low-speed surgical drill. The bone sections were observed under light microscopy and examined histologically. Thirty bone blocks were prepared from porcine ribs. On each block 2 holes (tunnel preparations) were performed using a low-speed, 1.0-mm-wide, surgical pilot drill and an Er:YAG laser (pulse energy, 1,000 mJ; pulse duration, 300 μs; frequency, 20 Hz). The temperature induced by the preparation techniques was measured using an infrared camera. The removed bone volume was calculated by a modified mathematical algorithm. The time required for the preparation was measured with a digital stopwatch and a time-measurement instrument integrated within the computer program. The cortical and spongiose surfaces of the specimens were examined microscopically and histologically under a light microscope with a high-resolution camera. The Er:YAG laser removed significantly more bone tissue than the drill (P < .01) in a significantly shorter time (P < .01). The temperature was statistically lower during the laser preparation (P < .01). Cavities prepared with the laser were regular with clear sharp edges and knifelike cuts. In the drill group, the preparations exhibited irregular edges full of bone fragments and fiberlike debris. Histologic examination of the laser sides showed a 30-μm-thick altered sublayer. The tissue in the drill group was covered with a smear layer without any alterations. The Er:YAG laser produced preparations with regular and sharp edges, without bone fragments and debris, in a shorter time, and with less generated heat. Thermal alterations in the treated surface were minimal. Copyright © 2012 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  11. How does implant distribution affect 3D correction and bone-screw forces in thoracic adolescent idiopathic scoliosis spinal instrumentation?

    PubMed

    Le Navéaux, Franck; Larson, A Noelle; Labelle, Hubert; Wang, Xiaoyu; Aubin, Carl-Éric

    2016-11-01

    Optimal implant densities and configurations for thoracic spine instrumentation to treat adolescent idiopathic scoliosis remain unknown. The objective was to computationally assess the biomechanical effects of implant distribution on 3D curve correction and bone-implant forces. 3D patient-specific biomechanical spine models based on a multibody dynamic approach were created for 9 Lenke 1 patients who underwent posterior instrumentation (main thoracic Cobb: 43°-70°). For each case, a factorial design of experiments was used to generate 128 virtual implant configurations representative of existing implant patterns used in clinical practice. All instances except implant configuration were the same for each surgical scenario simulation. Simulation of the 128 implant configurations scenarios (mean implant density=1.32, range: 0.73-2) revealed differences of 2° to 10° in Cobb angle correction, 2° to 7° in thoracic kyphosis and 2° to 7° in apical vertebral rotation. The use of more implants, at the concave side only, was associated with higher Cobb angle correction (r=-0.41 to -0.90). Increased implant density was associated with higher apical vertebral rotation correction for seven cases (r=-0.20 to -0.48). It was also associated with higher bone-screw forces (r=0.22 to 0.64), with an average difference between the least and most constrained instrumentation constructs of 107N per implant at the end of simulated instrumentation. Low-density constructs, with implants mainly placed on the concave side, resulted in similar simulated curve correction as the higher-density patterns. Increasing the number of implants allows for only limited improvement of 3D correction and overconstrains the instrumentation construct, resulting in increased forces on the implants. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Lamb Temporal Bone as a Surgical Training Model of Round Window Cochlear Implant Electrode Insertion.

    PubMed

    Mantokoudis, Georgios; Huth, Markus E; Weisstanner, Christian; Friedrich, Hergen M; Nauer, Claude; Candreia, Claudia; Caversaccio, Marco D; Senn, Pascal

    2016-01-01

    The preservation of residual hearing in cochlear implantation opens the door for optimal functional results. This atraumatic surgical technique requires training; however, the traditional human cadaveric temporal bones have become less available or unattainable in some institutions. This study investigates the suitability of an alternative model, using cadaveric lamb temporal bone, for surgical training of atraumatic round window electrode insertion. A total of 14 lamb temporal bones were dissected for cochlear implantation by four surgeons. After mastoidectomy, visualization, and drilling of the round window niche, an atraumatic round window insertion of a Medel Flex24 electrode was performed. Electrode insertion depth and position were verified by computed tomography scans. All cochleas were successfully implanted using the atraumatic round window approach; however, surgical access through the mastoid was substantially different when compared human anatomy. The mean number of intracochlear electrode contacts was 6.5 (range, 4-11) and the mean insertion depth 10.4 mm (range, 4-20 mm), which corresponds to a mean angular perimodiolar insertion depth of 229 degrees (range 67-540°). Full insertion of the electrode was not possible because of the smaller size of the lamb cochlea in comparison to that of the human. The lamb temporal bone model is well suited as a training model for atraumatic cochlear implantation at the level of the round window. The minimally pneumatized mastoid as well as the smaller cochlea can help prepare a surgeon for difficult cochlear implantations. Because of substantial differences to human anatomy, it is not an adequate training model for other surgical techniques such as mastoidectomy and posterior tympanotomy as well as full electrode insertion.

  13. Bone graft in the treatment of nonunion of the scaphoid with necrosis of the proximal pole: a literature review.

    PubMed

    Severo, Antônio Lourenço; Lemos, Marcelo Barreto; Lech, Osvandré Luiz Canfield; Barreto Filho, Danilo; Strack, Daniel Paulo; Candido, Larissa Knapp

    2017-01-01

    Scaphoid fractures are the most common fractures of the carpal bones, corresponding to 60%. Of these, 10% progress to nonunion; moreover, 3% can present necrosis of the proximal pole. There are various methods of treatment using vascularized and non-vascularized bone grafts. To evaluate and compare the rate of scaphoid consolidation with necrosis of the proximal pole using different surgical techniques. The authors conducted a review of the literature using the following databases: PubMed and BIREME/LILACS, where 13 case series were selected (ten with use of vascularized bone grafts and three of non-vascularized bone grafts), according to inclusion and exclusion criteria. In most cases VBGs were used, especially those based on the 1,2 intercompartmental supraretinacular artery, due to greater reproducibility in performing the surgical technique.

  14. Five years follow-up of implant-prosthetic rehabilitation on a patient after mandibular ameloblastoma removal and ridge reconstruction by fibula graft and bone distraction

    PubMed Central

    Oteri, Giacomo; Ponte, Francesco Saverio De; Pisano, Michele; Cicciù, Marco

    2012-01-01

    This case report presents a combination of surgical and prosthetic solutions applied to a case of oral implant rehabilitation in post-oncologic reconstructed mandible. Bone resection due to surgical treatment of large mandibular neoplasm can cause long-span defects. Currently, mandibular fibula free flap graft is widely considered as a reliable technique for restoring this kind of defect. It restores the continuity of removed segment and re-establishes the contour of the lower jaw. However, the limited height of grafted fibula does not allow the insertion of regular length implants, therefore favouring vertical distraction osteogenesis as an important treatment choice. This report presents a patient affected by extensive mandibular ameloblastoma who underwent surgical reconstruction by fibula free flap because of partial mandibular resection. Guided distraction osteoneogenesis technique was applied to grafted bone, in order to obtain adequate bone height and to realize a prosthetically guided placement of 8 fixtures. After osseointegration, the patient was rehabilitated with a full arch, screw-retained prosthetic restoration. At five-years follow up, excellent integration of grafted tissue, steady levels of bone around the fixtures and healthy peri-implant tissues were reported. PMID:22623943

  15. Comparison of Piezosurgery and Conventional Rotary Instruments for Removal of Impacted Mandibular Third Molars: A Randomized Controlled Clinical and Radiographic Trial

    PubMed Central

    Shokry, Mohamed; Aboelsaad, Nayer

    2016-01-01

    The purpose of this study was to test the effect of the surgical removal of impacted mandibular third molars using piezosurgery versus the conventional surgical technique on postoperative sequelae and bone healing. Material and Methods. This study was carried out as a randomized controlled clinical trial: split mouth design. Twenty patients with bilateral mandibular third molar mesioangular impaction class II position B indicated for surgical extraction were treated randomly using either the piezosurgery or the conventional bur technique on each site. Duration of the procedure, postoperative edema, trismus, pain, healing, and bone density and quantity were evaluated up to 6 months postoperatively. Results. Test and control sites were compared using paired t-test. There was statistical significance in reduction of pain and swelling in test sites, where the time of the procedure was statistically increased in test site. For bone quantity and quality, statistical difference was found where test site showed better results. Conclusion. Piezosurgery technique improves quality of patient's life in form of decrease of postoperative pain, trismus, and swelling. Furthermore, it enhances bone quality within the extraction socket and bone quantity along the distal aspect of the mandibular second molar. PMID:27597866

  16. Retained broken implants in the craniomaxillofacial skeleton.

    PubMed

    Nallathamby, Vigneswaran; Lee, Hanjing; Lin, Yap Yan; Lim, Jane; Ong, Wei Chen; Lim, Thiam-Chye

    2014-06-01

    Facial fracture patients are seen in a Level 1 trauma hospital. In our institution, we manage many patients with facial fractures and carry out more than 150 surgical procedures every year. Open reduction and internal fixation is our management of choice. All surgical procedures involve drilling of bone and implant insertion to keep the fractured bones in an anatomically reduced position to aid healing. Occasionally, drill bits used to create the pilot hole break and are embedded in the bone. We present a situation in which such an incident occurred and review the literature on retained broken implants and devices.

  17. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  18. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  19. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  20. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  1. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  2. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  3. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  4. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  5. 21 CFR 874.4800 - Bone particle collector.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Bone particle collector. 874.4800 Section 874.4800...) MEDICAL DEVICES EAR, NOSE, AND THROAT DEVICES Surgical Devices § 874.4800 Bone particle collector. (a) Identification. A bone particle collector is a filtering device intended to be inserted into a suction tube...

  6. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  7. Articulated Bone Block for Posterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft: Surgical Technique to Facilitate Graft Passage.

    PubMed

    Cugat, Ramón; Alentorn-Geli, Eduard; Cuscó, Xavier; Navarro, Jordi; Steinbacher, Gilbert; Álvarez-Díaz, Pedro; Seijas, Roberto; Barastegui, David; García-Balletbó, Montse

    2018-02-01

    Posterior cruciate ligament reconstruction using the transtibial technique provides successful clinical outcomes. However, a bone-patellar tendon-bone (BTB) autograft with the transtibial technique has not been used by some surgeons because of concerns with graft passage from the tibial to the femoral tunnels (sharp turn) that can damage graft fibers. In the present surgical technique, an arthroscopic, transtibial, single-bundle technique for posterior cruciate ligament reconstruction using the BTB autograft with an easy and effective technical tip to facilitate graft passage is presented. Once the BTB is harvested, the femoral bone block is divided into 2 equal-sized blocks providing an articulated structure while preserving the tendon component. This facilitates the passage of the BTB tendon once it is entered in the posterior tibia and the graft has to make a sharp turn to reach the femoral tunnel. This easy and effective technique tip may avoid graft damage during the sharp turn, while maintaining all the advantages of a BTB autograft (bone-to-bone healing, own tissue with fast incorporation, and strong fixation and stability).

  8. Infrared Thermal Imaging During Ultrasonic Aspiration of Bone

    NASA Astrophysics Data System (ADS)

    Cotter, D. J.; Woodworth, G.; Gupta, S. V.; Manandhar, P.; Schwartz, T. H.

    Ultrasonic surgical aspirator tips target removal of bone in approaches to tumors or aneurysms. Low profile angled tips provide increased visualization and safety in many high risk surgical situations that commonly were approached using a high speed rotary drill. Utilization of the ultrasonic aspirator for bone removal raised questions about relative amount of local and transmitted heat energy. In the sphenoid wing of a cadaver section, ultrasonic bone aspiration yielded lower thermal rise in precision bone removal than rotary mechanical drills, with maximum temperature of 31 °C versus 69 °C for fluted and 79 °C for diamond drill bits. Mean ultrasonic fragmentation power was about 8 Watts. Statistical studies using tenacious porcine cranium yielded mean power levels of about 4.5 Watts to 11 Watts and mean temperature of less than 41.1 °C. Excessively loading the tip yielded momentary higher power; however, mean thermal rise was less than 8 °C with bone removal starting at near body temperature of about 37 °C. Precision bone removal and thermal management were possible with conditions tested for ultrasonic bone aspiration.

  9. Unicameral and aneurysmal bone cysts.

    PubMed

    Campanacci, M; Capanna, R; Picci, P

    1986-03-01

    One hundred and seventy-eight cases of unicameral bone cysts (UBC) treated with curettage and bone grafting were compared to 141 cases treated with cortisone injections. The end results were comparable in the two groups. Local recurrence risk factors in the surgical group were active cyst and previous operations. In the other group they were multilocation of the cyst, active cyst, and size of cyst. A new radiographic classification of aneurysmal bone cyst (ABC) is proposed in a report of 198 cases of ABC. The treatment of choice in ABC is surgical and the type (curettage, curettage plus phenole or cryosurgery, resection or hemiresection) is selected on the basis of the radiographic aspect and the rate of growth of the cyst. Radiotherapy is only indicated in inoperable ABC cases.

  10. Laser vs bur for bone cutting in impacted mandibular third molar surgery: A randomized controlled trial

    PubMed Central

    Passi, Deepak; Pal, Uma Shankar; Mohammad, Shadab; Singh, Rakesh Kumar; Mehrotra, Divya; Singh, Geeta; Kumar, Manoj; Chellappa, Arul A.L.; Gupta, Chandan

    2013-01-01

    Background The aim of this study was to assess the feasibility of Er: YAG laser in bone cutting for removal of impacted lower third molar teeth and compare its outcomes with that of surgical bur. Materials & methods The study comprised 40 subjects requiring removal of impacted mandibular third molar, randomly categorized into two equal groups of 20 each, who had their impacted third molar removed either using Er: YAG laser or surgical bur as per their group, using standard methodology of extraction of impacted teeth. Clinical parameters like pain, bleeding, time taken for bone cutting, postoperative swelling, trismus, wound healing and complications were compared for both groups. Observation & result Clinical parameters like pain, bleeding and swelling were lower in laser group than bur group, although the difference was statistically not significant. However, postoperative swelling showed significant difference in the two groups. Laser group required almost double the time taken for bone cutting with bur. Trismus persisted for a longer period in laser group. Wound healing and complications were assessed clinically and there was no significant difference in both the groups. Conclusion Based on the results of our study, the possibility of bone cutting using lasers is pursued, the osteotomy is easily performed and the technique is better suited to minimally invasive surgical procedures. The use of Er: YAG laser may be considered as an alternative tool to surgical bur, specially in anxious patients. PMID:25737885

  11. Surgical repositioning of the premaxilla with bone graft in 50 bilateral cleft lip and palate patients.

    PubMed

    Carlini, João L; Biron, Cassia; Gomes, Kelston Ulbricht; Da Silva, Rafael M

    2009-04-01

    The aim of this study was to evaluate a modified surgical technique for premaxilla repositioning with concomitant autogenous bone grafting in bilateral trans-foramen cleft lip and palate patients. The study included 50 bilateral trans-foramen cleft lip and palate patients. Bone graft was harvested from the mandibular symphysis in 24 patients. Whenever more grafting was necessary, the iliac crest bone was used as the donor site (26 patients). The premaxilla was displaced by rupturing the bone and the palatine mucosa, and repositioned in a more adequate position using a surgical guide. The premaxilla and the grafts were fixed with miniplates and screws or screws only. The surgical guide was kept in place for 2 months, whereas the miniplates and screws were removed after 6 months, together with the complete bilateral lip and nose repair. Follow-up examinations were performed at 3, 6, and 12 months by means of periapical and occlusal radiographs, and by clinical examination. Thereafter, the patients were referred for completion of the orthodontic treatment. Overall, in 48 cases (96%) the treatment achieved total graft integration, with complete closure of the bucconasal and palatal fistulas, and premaxilla stability (either at first surgery or after reoperation). In the remaining 2 patients (4%), the treatment failed, due to necrosis of the premaxilla. The procedure is complex and involves risk. However, the patient's social inclusion, especially at the addressed age group, is the best benefit achieved.

  12. Open surgical simulation--a review.

    PubMed

    Davies, Jennifer; Khatib, Manaf; Bello, Fernando

    2013-01-01

    Surgical simulation has benefited from a surge in interest over the last decade as a result of the increasing need for a change in the traditional apprentice model of teaching surgery. However, despite the recent interest in surgical simulation as an adjunct to surgical training, most of the literature focuses on laparoscopic, endovascular, and endoscopic surgical simulation with very few studies scrutinizing open surgical simulation and its benefit to surgical trainees. The aim of this review is to summarize the current standard of available open surgical simulators and to review the literature on the benefits of open surgical simulation. Open surgical simulators currently used include live animals, cadavers, bench models, virtual reality, and software-based computer simulators. In the current literature, there are 18 different studies (including 6 randomized controlled trials and 12 cohort studies) investigating the efficacy of open surgical simulation using live animal, bench, and cadaveric models in many surgical specialties including general, cardiac, trauma, vascular, urologic, and gynecologic surgery. The current open surgical simulation studies show, in general, a significant benefit of open surgical simulation in developing the surgical skills of surgical trainees. However, these studies have their limitations including a low number of participants, variable assessment standards, and a focus on short-term results often with no follow-up assessment. The skills needed for open surgical procedures are the essential basis that a surgical trainee needs to grasp before attempting more technical procedures such as laparoscopic procedures. In this current climate of medical practice with reduced hours of surgical exposure for trainees and where the patient's safety and outcome is key, open surgical simulation is a promising adjunct to modern surgical training, filling the void between surgeons being trained in a technique and a surgeon achieving fluency in that open surgical procedure. Better quality research is needed into the benefits of open surgical simulation, and this would hopefully stimulate further development of simulators with more accurate and objective assessment tools. © 2013 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  13. Cranial reconstruction: 3D biomodel and custom-built implant created using additive manufacturing.

    PubMed

    Jardini, André Luiz; Larosa, Maria Aparecida; Maciel Filho, Rubens; Zavaglia, Cecília Amélia de Carvalho; Bernardes, Luis Fernando; Lambert, Carlos Salles; Calderoni, Davi Reis; Kharmandayan, Paulo

    2014-12-01

    Additive manufacturing (AM) technology from engineering has helped to achieve several advances in the medical field, particularly as far as fabrication of implants is concerned. The use of AM has made it possible to carry out surgical planning and simulation using a three-dimensional physical model which accurately represents the patient's anatomy. AM technology enables the production of models and implants directly from a 3D virtual model, facilitating surgical procedures and reducing risks. Furthermore, AM has been used to produce implants designed for individual patients in areas of medicine such as craniomaxillofacial surgery, with optimal size, shape and mechanical properties. This work presents AM technologies which were applied to design and fabricate a biomodel and customized implant for the surgical reconstruction of a large cranial defect. A series of computed tomography data was obtained and software was used to extract the cranial geometry. The protocol presented was used to create an anatomic biomodel of the bone defect for surgical planning and, finally, the design and manufacture of the patient-specific implant. Copyright © 2014 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  14. Prospective Analysis of Surgical Bone Margins After Partial Foot Amputation in Diabetic Patients Admitted With Moderate to Severe Foot Infections.

    PubMed

    Schmidt, Brian M; McHugh, Jonathan B; Patel, Rajiv M; Wrobel, James S

    2018-04-01

    Osteomyelitis is common in diabetic foot infections and medical management can lead to poor outcomes. Surgical management involves sending histopathologic and microbiologic specimens which guides future intervention. We examined the effect of obtainment of surgical margins in patients undergoing forefoot amputations to identify patient characteristics associated with outcomes. Secondary aims included evaluating interobserver reliability of histopathologic data at both the distal-to and proximal-to surgical bone margin. Data were prospectively collected on 72 individuals and was pooled for analysis. Standardized method to retrieve intraoperative bone margins was established. A univariate analysis was performed. Negative outcomes, including major lower extremity amputation, wound dehiscence, reulceration, reamputation, or death were recorded. Viable proximal margins were obtained in 63 out of 72 cases (87.5%). Strong interobserver reliability of histopathology was recorded. Univariate analysis demonstrated preoperative platelets, albumin, probe-to-bone testing, absolute toe pressures, smaller wound surface area were associated with obtaining viable margins. Residual osteomyelitis resulted in readmission 2.6 times more often and more postoperative complications. Certain patients were significantly different in the viable margin group versus dirty margin group. High interobserver reliability was demonstrated. Obtainment of viable margins resulted in reduced rates of readmission and negative outcomes. Prognostic, Level I: Prospective.

  15. Iliac crest bone graft: a 23-years hystory of infection at donor site in vertebral arthrodesis and a review of current bone substitutes.

    PubMed

    Babbi, L; Barbanti-Brodano, G; Gasbarrini, A; Boriani, S

    2016-11-01

    This is an exemplary case report underlining a relevant morbidity which could be associated to the use of autologous iliac crest bone graft (ICBG) for spine fusion. Starting from 1990, a 25-years-old woman underwent two subsequent surgical treatments for non-Hodgkin lymphoma vertebral localizations. In the second surgery, arthrodesis was obtained with autograft through right posterior iliac crest osteotomy. During the chemotherapy treatment following the surgery, the patient suffered from infection at posterior iliac crest scar, the site of previous graft, caused by methicillin-resistant Staphylococcus aureus. She was subjected to surgical debridement and specific antibiotic treatment with local healing and phlogosis index reduction. Chemotherapy protocol was concluded and the patient healed with definitive lymphoma remission. After 22 years the patient had a relapse of donor site infection, requiring a new antibiotic therapy and a new surgical debridement. The relapsed infection at donor site lasted for a long period, more than one year, despite of specific care. It finally healed after another accurate surgical debridement and postoperative antibiotic therapy. This case report underlines the possible consequences on the patient's quality of life of a long-term disease affecting the iliac crest bone graft donor site. Literature concerning alternatives to autograft for spine fusion is also reviewed.

  16. Post-treatment glenoid classification system for total shoulder arthroplasty.

    PubMed

    Churchill, R Sean

    2012-04-01

    Over the past 10 years, numerous advancements in glenoid preparation and resurfacing have occurred. Current glenoid classification systems are either focused solely on the patient's preoperative glenoid bone configuration or on the available glenoid bone stock in revision arthroplasty cases. While these systems provide value in preoperative planning, they fail to properly classify the surgical reconstruction completed. A literature review of common bone preparation methods and sources of glenoid prosthetic failure was performed. Based upon this review, a classification system for grading the status of the glenoid after prosthetic implantation was developed. A 6 category, post-treatment, glenoid classification system is proposed: type 0: no reaming; type I: glenoid reaming into but not through the subchondral bone; type II: glenoid reaming which perforates through <50% of the subchondral bone surface area; type III: glenoid reaming which perforates through >50% of the subchondral bone surface area; type IV: use of structural bone graft; and type V: use of a posterior augmented glenoid prosthesis. Types I-III are further subdivided into subtype A which have 100% bone support of the prosthesis, and subtype B which have a region of unsupported prosthesis. The classification system proposed addresses the surgical management of the glenoid during prosthetic replacement. This unique approach to classifying the glenoid following surgical intervention will allow direct follow-up comparison of similarly treated glenoid replacements. Future multicenter studies, possibly through joint registry databases, could then determine the long-term efficacy of the various glenoid preparation methods. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  17. Assessment of digital panoramic radiography's diagnostic value in angular bony lesions with 5 mm or deeper pocket depth in mandibular molars.

    PubMed

    Saberi, Bardia Vadiati; Nemati, Somayeh; Malekzadeh, Meisam; Javanmard, Afrooz

    2017-01-01

    Assessment of alveolar bone level in periodontitis is very important in determining prognosis and treatment plan. Panoramic radiography is a diagnostic tool used to screen patients. The aim of the present study was to assess the diagnostic value of digital panoramic radiography in angular bony defects with 5 mm or deeper pocket depth in mandibular molars. In this cross-sectional study, ninety angular bony defects in mandibular molars teeth with 5 mm or deeper pocket depth were selected in sixty patients with the diagnosis of chronic periodontitis. Before surgery, bone probing was performed. During the surgery, the vertical distance from cementoenamel junction to the most apical part of bony defect was measured using a Williams probe and this measurements were employed as gold standard. This distance was measured on the panoramic radiographs by a Digital Calliper and Digital Ruler. All data were compare dusing independent samples t -test and Pearson's correlation coefficient. No significant difference was found between the results of bone probing and intra-surgical measurements ( P = 0.377). The mean defect depth determined by Digital Caliper and Digital Ruler on panoramic radiographs was significantly less than surgical measurements ( P < 0.001). The correlation between bone probing and surgical measurements in determining the defect depth was strong ( r = 0.98, P < 0.001). Radiographic measurements made by Digital Ruler ( r = 0.86), comparing to Digital Caliper ( r = 0.79), showed a higher degree of correlation with surgical measurements. Based on this study, bone probing is a reliable method in vertical alveolar bone defect measurements. While the information obtained from digital panoramic radiographs should be used with caution and the ability of digital panoramic radiography in the determination of defect depth is limited.

  18. Age-dependent Changes in the Articular Cartilage and Subchondral Bone of C57BL/6 Mice after Surgical Destabilization of Medial Meniscus.

    PubMed

    Huang, Henry; Skelly, Jordan D; Ayers, David C; Song, Jie

    2017-02-09

    Age is the primary risk factor for osteoarthritis (OA), yet surgical OA mouse models such as destabilization of the medial meniscus (DMM) used for evaluating disease-modifying OA targets are frequently performed on young adult mice only. This study investigates how age affects cartilage and subchondral bone changes in mouse joints following DMM. DMM was performed on male C57BL/6 mice at 4 months (4 M), 12 months (12 M) and 19+ months (19 M+) and on females at 12 M and 18 M+. Two months after surgery, operated and unoperated contralateral knees were harvested and evaluated using cartilage histology scores and μCT quantification of subchondral bone plate thickness and osteophyte formation. The 12 M and 19 M+ male mice developed more cartilage erosions and thicker subchondral bone plates after DMM than 4 M males. The size of osteophytes trended up with age, while the bone volume fraction was significantly higher in the 19 M+ group. Furthermore, 12 M females developed milder OA than males as indicated by less cartilage degradation, less subchondral bone plate sclerosis and smaller osteophytes. Our results reveal distinct age/gender-dependent structural changes in joint cartilage and subchondral bone post-DMM, facilitating more thoughtful selection of murine age/gender when using this surgical technique for translational OA research.

  19. Age-dependent Changes in the Articular Cartilage and Subchondral Bone of C57BL/6 Mice after Surgical Destabilization of Medial Meniscus

    PubMed Central

    Huang, Henry; Skelly, Jordan D.; Ayers, David C.; Song, Jie

    2017-01-01

    Age is the primary risk factor for osteoarthritis (OA), yet surgical OA mouse models such as destabilization of the medial meniscus (DMM) used for evaluating disease-modifying OA targets are frequently performed on young adult mice only. This study investigates how age affects cartilage and subchondral bone changes in mouse joints following DMM. DMM was performed on male C57BL/6 mice at 4 months (4 M), 12 months (12 M) and 19+ months (19 M+) and on females at 12 M and 18 M+. Two months after surgery, operated and unoperated contralateral knees were harvested and evaluated using cartilage histology scores and μCT quantification of subchondral bone plate thickness and osteophyte formation. The 12 M and 19 M+ male mice developed more cartilage erosions and thicker subchondral bone plates after DMM than 4 M males. The size of osteophytes trended up with age, while the bone volume fraction was significantly higher in the 19 M+ group. Furthermore, 12 M females developed milder OA than males as indicated by less cartilage degradation, less subchondral bone plate sclerosis and smaller osteophytes. Our results reveal distinct age/gender-dependent structural changes in joint cartilage and subchondral bone post-DMM, facilitating more thoughtful selection of murine age/gender when using this surgical technique for translational OA research. PMID:28181577

  20. Bone Regeneration Based on Tissue Engineering Conceptions — A 21st Century Perspective

    PubMed Central

    Henkel, Jan; Woodruff, Maria A.; Epari, Devakara R.; Steck, Roland; Glatt, Vaida; Dickinson, Ian C.; Choong, Peter F. M.; Schuetz, Michael A.; Hutmacher, Dietmar W.

    2013-01-01

    The role of Bone Tissue Engineering in the field of Regenerative Medicine has been the topic of substantial research over the past two decades. Technological advances have improved orthopaedic implants and surgical techniques for bone reconstruction. However, improvements in surgical techniques to reconstruct bone have been limited by the paucity of autologous materials available and donor site morbidity. Recent advances in the development of biomaterials have provided attractive alternatives to bone grafting expanding the surgical options for restoring the form and function of injured bone. Specifically, novel bioactive (second generation) biomaterials have been developed that are characterised by controlled action and reaction to the host tissue environment, whilst exhibiting controlled chemical breakdown and resorption with an ultimate replacement by regenerating tissue. Future generations of biomaterials (third generation) are designed to be not only osteoconductive but also osteoinductive, i.e. to stimulate regeneration of host tissues by combining tissue engineering and in situ tissue regeneration methods with a focus on novel applications. These techniques will lead to novel possibilities for tissue regeneration and repair. At present, tissue engineered constructs that may find future use as bone grafts for complex skeletal defects, whether from post-traumatic, degenerative, neoplastic or congenital/developmental “origin” require osseous reconstruction to ensure structural and functional integrity. Engineering functional bone using combinations of cells, scaffolds and bioactive factors is a promising strategy and a particular feature for future development in the area of hybrid materials which are able to exhibit suitable biomimetic and mechanical properties. This review will discuss the state of the art in this field and what we can expect from future generations of bone regeneration concepts. PMID:26273505

  1. A new method of morphological comparison for bony reconstructive surgery: maxillary reconstruction using scapular tip bone

    NASA Astrophysics Data System (ADS)

    Chan, Harley; Gilbert, Ralph W.; Pagedar, Nitin A.; Daly, Michael J.; Irish, Jonathan C.; Siewerdsen, Jeffrey H.

    2010-02-01

    esthetic appearance is one of the most important factors for reconstructive surgery. The current practice of maxillary reconstruction chooses radial forearm, fibula or iliac rest osteocutaneous to recreate three-dimensional complex structures of the palate and maxilla. However, these bone flaps lack shape similarity to the palate and result in a less satisfactory esthetic. Considering similarity factors and vasculature advantages, reconstructive surgeons recently explored the use of scapular tip myo-osseous free flaps to restore the excised site. We have developed a new method that quantitatively evaluates the morphological similarity of the scapula tip bone and palate based on a diagnostic volumetric computed tomography (CT) image. This quantitative result was further interpreted as a color map that rendered on the surface of a three-dimensional computer model. For surgical planning, this color interpretation could potentially assist the surgeon to maximize the orientation of the bone flaps for best fit of the reconstruction site. With approval from the Research Ethics Board (REB) of the University Health Network, we conducted a retrospective analysis with CT image obtained from 10 patients. Each patient had a CT scans including the maxilla and chest on the same day. Based on this image set, we simulated total, subtotal and hemi palate reconstruction. The procedure of simulation included volume segmentation, conversing the segmented volume to a stereo lithography (STL) model, manual registration, computation of minimum geometric distances and curvature between STL model. Across the 10 patients data, we found the overall root-mean-square (RMS) conformance was 3.71+/- 0.16 mm

  2. Maintaining space in localized ridge augmentation using guided bone regeneration with tenting screw technology.

    PubMed

    Chasioti, Evdokia; Chiang, Tat Fai; Drew, Howard J

    2013-01-01

    Prosthetic guided implant surgery requires adequate ridge dimensions for proper implant placement. Various surgical procedures can be used to augment deficient alveolar ridges. Studies have examined new bone formation on deficient ridges, utilizing numerous surgical techniques and biomaterials. The goal is to develop time efficient techniques, which have low morbidity. A crucial factor for successful bone grafting procedures is space maintenance. The article discusses space maintenance tenting screws, used in conjunction with bone allografts and resorbable barrier membranes, to ensure uneventful guided bone regeneration (GBR) enabling optimal implant positioning. The technique utilized has been described in the literature to treat severely resorbed alveolar ridges and additionally can be considered in restoring the vertical and horizontal component of deficient extraction sites. Three cases are presented to illustrate the utilization and effectiveness of tenting screw technology in the treatment of atrophic extraction sockets and for deficient ridges.

  3. Scaffold-based Anti-infection Strategies in Bone Repair

    PubMed Central

    Johnson, Christopher T.; García, Andrés J.

    2014-01-01

    Bone fractures and non-union defects often require surgical intervention where biomaterials are used to correct the defect, and approximately 10% of these procedures are compromised by bacterial infection. Currently, treatment options are limited to sustained, high doses of antibiotics and surgical debridement of affected tissue, leaving a significant, unmet need for the development of therapies to combat device-associated biofilm and infections. Engineering implants to prevent infection is a desirable material characteristic. Tissue engineered scaffolds for bone repair provide a means to both regenerate bone and serve as a base for adding antimicrobial agents. Incorporating anti-infection properties into regenerative medicine therapies could improve clinical outcomes and reduce the morbidity and mortality associated with biomaterial implant-associated infections. This review focuses on current animal models and technologies available to assess bone repair in the context of infection, antimicrobial agents to fight infection, the current state of antimicrobial scaffolds, and future directions in the field. PMID:25476163

  4. Osseointegration of Plateau Root Form Implants: Unique Healing Pathway Leading to Haversian-Like Long-Term Morphology.

    PubMed

    Coelho, Paulo G; Suzuki, Marcelo; Marin, Charles; Granato, Rodrigo; Gil, Luis F; Tovar, Nick; Jimbo, Ryo; Neiva, Rodrigo; Bonfante, Estevam A

    2015-01-01

    Endosteal dental implants have been utilized as anchors for dental and orthopedic rehabilitations for decades with one of the highest treatment success rates in medicine. Such success is due to the phenomenon of osseointegration where after the implant surgical placement, bone healing results into an intimate contact between bone and implant surface. While osseointegration is an established phenomenon, the route which osseointegration occurs around endosteal implants is related to various implant design factors including surgical instrumentation and implant macro, micro, and nanometer scale geometry. In an implant system where void spaces (healing chambers) are present between the implant and bone immediately after placement, its inherent bone healing pathway results in unique opportunities to accelerate the osseointegration phenomenon at the short-term and its maintenance on the long-term through a haversian-like bone morphology and mechanical properties.

  5. Theoretical prediction of pullout strengths for dental and orthopaedic screws with conical profile and buttress threads.

    PubMed

    Shih, Kao-Shang; Hou, Sheng-Mou; Lin, Shang-Chih

    2017-12-01

    The pullout strength of a screw is an indicator of how secure bone fragments are being held in place. Such bone-purchasing ability is sensitive to bone quality, thread design, and the pilot hole, and is often evaluated by experimental and numerical methods. Historically, there are some mathematical formulae to simulate the screw withdrawal from the synthetic bone. There are great variations in screw specifications. However, extensive investigation of the correlation between experimental and analytical results has not been reported in literature. Referring to the literature formulae, this study aims to evaluate the differences in the calculated pullout strengths. The pullout tests of the surgical screws are measured and the sawbone is used as the testing block. The absolute errors and correlation coefficients of the experimental and analytical results are calculated as the comparison baselines of the formulae. The absolute error of the dental, traumatic, and spinal groups are 21.7%, 95.5%, and 37.0%, respectively. For the screws with a conical profile and/or tiny threads, the calculated and measured results are not well correlated. The formulae are not accurate indicators of the pullout strengths of the screws where the design parameters are slightly varied. However, the experimental and numerical results are highly correlated for the cylindrical screws. The pullout strength of a conical screw is higher than that of its counterpart, but all formulae consistently predict the opposite results. In general, the bony purchase of the buttress threads is securer than that of the symmetric thread. An absolute error of up to 51.4% indicates the theoretical results cannot predict the actual value of the pullout strength. Only thread diameter, pitch, and depth are considered in the investigated formulae. The thread profile and shape should be formulated to modify the slippage mechanism at the bone-screw interfaces and simulate the strength change in the squeezed bones, especially for the conical screw. Copyright © 2017. Published by Elsevier B.V.

  6. Dual-Purpose Bone Grafts Improve Healing and Reduce Infection

    DTIC Science & Technology

    2011-08-01

    However, a second surgical procedure is required to remove the PMMA beads before implantation of the graft. Furthermore, the bone graft is a foreign...procedure.1 In practice, poly(methyl methacrylate) ( PMMA ) cement beads have been used as the local antibiotic delivery platform, which has been shown to...decrease infection in a number of clinical studies.2 However, PMMA is nonbiodegradable and must be removed during a second surgical step before

  7. Surgical, Orthodontic and Prosthodontic Rehabilitation of a Patient with Follicular Ameloblastoma: A Case Report

    PubMed Central

    Sailer, Herman F.; Tarawneh, Fadi; Fourkas, Panagiotis; Antoniades, Dimitrios Z.; Athanasiou, Athanasios E.

    2010-01-01

    This case report describes the combined surgical, orthodontic and prosthodontic rehabilitation of an adult female patient with a previous history of follicular ameloblastoma, which was treated through partial mandibulectomy and an immediate replacement of missing bone with an autologous calvarial bone graft. Orthodontic treatment was undertaken in order to restore occlusal disturbances and obtain sufficient space for two dental implants and an optimum prosthodontic rehabilitation. PMID:20396452

  8. Juvenile aggressive cemento-ossifying fibroma of the sphenoid sinus with proptosis: a surgical dilemma

    PubMed Central

    Singh, Rohit; Ramaswamy, Balakrishnan; Hazarika, Manali

    2013-01-01

    The term fibro-osseous lesion has currently grown in popularity as an overall designation for a number of rare, histologically benign head and neck lesions that are made up of bone, fibrous tissue and cementum. Cemento-ossifying fibroma is a variant of cementifying fibroma and is a fibro-osseous disease. They are usually small innocuous lesions which follow a slow benign course and are commonly seen in the skull bone rather than the sphenoid. It is rare for these tumours to attain large size, behave aggressively, destroy bone and require a radical surgery. One such rapidly growing juvenile cemento-ossifying lesion of sphenoid in our 10-year-old young patient causing proptosis and impaired vision is reported here because of its uncommon nature and its surgical dilemma. Selection of surgical approach to resect this tumour becomes difficult because it is deeply seated and needs a multidisciplinary approach. PMID:24285811

  9. Juvenile aggressive cemento-ossifying fibroma of the sphenoid sinus with proptosis: a surgical dilemma.

    PubMed

    Singh, Rohit; Ramaswamy, Balakrishnan; Hazarika, Manali

    2013-11-27

    The term fibro-osseous lesion has currently grown in popularity as an overall designation for a number of rare, histologically benign head and neck lesions that are made up of bone, fibrous tissue and cementum. Cemento-ossifying fibroma is a variant of cementifying fibroma and is a fibro-osseous disease. They are usually small innocuous lesions which follow a slow benign course and are commonly seen in the skull bone rather than the sphenoid. It is rare for these tumours to attain large size, behave aggressively, destroy bone and require a radical surgery. One such rapidly growing juvenile cemento-ossifying lesion of sphenoid in our 10-year-old young patient causing proptosis and impaired vision is reported here because of its uncommon nature and its surgical dilemma. Selection of surgical approach to resect this tumour becomes difficult because it is deeply seated and needs a multidisciplinary approach.

  10. Defining the lateral limits of the endoscopic endonasal transtuberculum transplanum approach: anatomical study with pertinent quantitative analysis.

    PubMed

    Di Somma, Alberto; Torales, Jorge; Cavallo, Luigi Maria; Pineda, Jose; Solari, Domenico; Gerardi, Rosa Maria; Frio, Federico; Enseñat, Joaquim; Prats-Galino, Alberto; Cappabianca, Paolo

    2018-04-20

    OBJECTIVE The extended endoscopic endonasal transtuberculum transplanum approach is currently used for the surgical treatment of selected midline anterior skull base lesions. Nevertheless, the possibility of accessing the lateral aspects of the planum sphenoidale could represent a limitation for such an approach. To the authors' knowledge, a clear definition of the eventual anatomical boundaries has not been delineated. Hence, the present study aimed to detail and quantify the maximum amount of bone removal over the planum sphenoidale required via the endonasal pathway to achieve the most lateral extension of such a corridor and to evaluate the relative surgical freedom. METHODS Six human cadaveric heads were dissected at the Laboratory of Surgical NeuroAnatomy of the University of Barcelona. The laboratory rehearsals were run as follows: 1) preliminary predissection CT scans, 2) the endoscopic endonasal transtuberculum transplanum approach (lateral limit: medial optocarotid recess) followed by postdissection CT scans, 3) maximum lateral extension of the transtuberculum transplanum approach followed by postdissection CT scans, and 4) bone removal and surgical freedom analysis (a nonpaired Student t-test). A conventional subfrontal bilateral approach was used to evaluate, from above, the bone removal from the planum sphenoidale and the lateral limit of the endonasal route. RESULTS The endoscopic endonasal transtuberculum transplanum approach was extended at its maximum lateral aspect in the lateral portion of the anterior skull base, removing the bone above the optic prominence, that is, the medial portion of the lesser sphenoid wing, including the anterior clinoid process. As expected, a greater bone removal volume was obtained compared with the approach when bone removal is limited to the medial optocarotid recess (average 533.45 vs 296.07 mm 2 ; p < 0.01). The anteroposterior diameter was an average of 8.1 vs 15.78 mm, and the laterolateral diameter was an average of 18.77 vs 44.54 mm (p < 0.01). The neurovascular contents of this area were exposed up to the insular segment of the middle cerebral artery. The surgical freedom analysis revealed a possible increased lateral maneuverability of instruments inserted in the contralateral nostril compared with a midline target (average 384.11 vs 235.31 mm 2 ; p < 0.05). CONCLUSIONS Bone removal from the medial aspect of the lesser sphenoid wing, including the anterior clinoid process, may increase the exposure and surgical freedom of the extended endoscopic endonasal transtuberculum transplanum approach over the lateral segment of the anterior skull base. Although this study represents a preliminary anatomical investigation, it could be useful to refine the indications and limitations of the endoscopic endonasal corridor for the surgical management of skull base lesions involving the lateral portion of the planum sphenoidale.

  11. Surgical simulation: a urological perspective.

    PubMed

    Wignall, Geoffrey R; Denstedt, John D; Preminger, Glenn M; Cadeddu, Jeffrey A; Pearle, Margaret S; Sweet, Robert M; McDougall, Elspeth M

    2008-05-01

    Surgical education is changing rapidly as several factors including budget constraints and medicolegal concerns limit opportunities for urological trainees. New methods of skills training such as low fidelity bench trainers and virtual reality simulators offer new avenues for surgical education. In addition, surgical simulation has the potential to allow practicing surgeons to develop new skills and maintain those they already possess. We provide a review of the background, current status and future directions of surgical simulators as they pertain to urology. We performed a literature review and an overview of surgical simulation in urology. Surgical simulators are in various stages of development and validation. Several simulators have undergone extensive validation studies and are in use in surgical curricula. While virtual reality simulators offer the potential to more closely mimic reality and present entire operations, low fidelity simulators remain useful in skills training, particularly for novices and junior trainees. Surgical simulation remains in its infancy. However, the potential to shorten learning curves for difficult techniques and practice surgery without risk to patients continues to drive the development of increasingly more advanced and realistic models. Surgical simulation is an exciting area of surgical education. The future is bright as advancements in computing and graphical capabilities offer new innovations in simulator technology. Simulators must continue to undergo rigorous validation studies to ensure that time spent by trainees on bench trainers and virtual reality simulators will translate into improved surgical skills in the operating room.

  12. The visible ear simulator: a public PC application for GPU-accelerated haptic 3D simulation of ear surgery based on the visible ear data.

    PubMed

    Sorensen, Mads Solvsten; Mosegaard, Jesper; Trier, Peter

    2009-06-01

    Existing virtual simulators for middle ear surgery are based on 3-dimensional (3D) models from computed tomographic or magnetic resonance imaging data in which image quality is limited by the lack of detail (maximum, approximately 50 voxels/mm3), natural color, and texture of the source material.Virtual training often requires the purchase of a program, a customized computer, and expensive peripherals dedicated exclusively to this purpose. The Visible Ear freeware library of digital images from a fresh-frozen human temporal bone was segmented, and real-time volume rendered as a 3D model of high-fidelity, true color, and great anatomic detail and realism of the surgically relevant structures. A haptic drilling model was developed for surgical interaction with the 3D model. Realistic visualization in high-fidelity (approximately 125 voxels/mm3) and true color, 2D, or optional anaglyph stereoscopic 3D was achieved on a standard Core 2 Duo personal computer with a GeForce 8,800 GTX graphics card, and surgical interaction was provided through a relatively inexpensive (approximately $2,500) Phantom Omni haptic 3D pointing device. This prototype is published for download (approximately 120 MB) as freeware at http://www.alexandra.dk/ves/index.htm.With increasing personal computer performance, future versions may include enhanced resolution (up to 8,000 voxels/mm3) and realistic interaction with deformable soft tissue components such as skin, tympanic membrane, dura, and cholesteatomas-features some of which are not possible with computed tomographic-/magnetic resonance imaging-based systems.

  13. Application of Additive Manufacturing in Oral and Maxillofacial Surgery.

    PubMed

    Farré-Guasch, Elisabet; Wolff, Jan; Helder, Marco N; Schulten, Engelbert A J M; Forouzanfar, Tim; Klein-Nulend, Jenneke

    2015-12-01

    Additive manufacturing is the process of joining materials to create objects from digital 3-dimensional (3D) model data, which is a promising technology in oral and maxillofacial surgery. The management of lost craniofacial tissues owing to congenital abnormalities, trauma, or cancer treatment poses a challenge to oral and maxillofacial surgeons. Many strategies have been proposed for the management of such defects, but autogenous bone grafts remain the gold standard for reconstructive bone surgery. Nevertheless, cell-based treatments using adipose stem cells combined with osteoconductive biomaterials or scaffolds have become a promising alternative to autogenous bone grafts. Such treatment protocols often require customized 3D scaffolds that fulfill functional and esthetic requirements, provide adequate blood supply, and meet the load-bearing requirements of the head. Currently, such customized 3D scaffolds are being manufactured using additive manufacturing technology. In this review, 2 of the current and emerging modalities for reconstruction of oral and maxillofacial bone defects are highlighted and discussed, namely human maxillary sinus floor elevation as a valid model to test bone tissue-engineering approaches enabling the application of 1-step surgical procedures and seeding of Good Manufacturing Practice-level adipose stem cells on computer-aided manufactured scaffolds to reconstruct large bone defects in a 2-step surgical procedure, in which cells are expanded ex vivo and seeded on resorbable scaffolds before implantation. Furthermore, imaging-guided tissue-engineering technologies to predetermine the surgical location and to facilitate the manufacturing of custom-made implants that meet the specific patient's demands are discussed. The potential of tissue-engineered constructs designed for the repair of large oral and maxillofacial bone defects in load-bearing situations in a 1-step surgical procedure combining these 2 innovative approaches is particularly emphasized. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Surgical Treatment of Implants Affected by Periimplantitis After 15 Years of Loading: A Case Report.

    PubMed

    Nícoli, Lélis Gustavo; Pigossi, Suzane Cristina; Marcantonio, Cláudio; Leal Zandim-Barcelos, Daniela; Marcantonio, Elcio

    2016-04-01

    The aim of this case report is to describe the surgical treatment of 2 implants affected by periimplantitis after 15 years of loading. The treatment included mechanical and chemical decontamination with topical application of tetracycline associated with a regenerative approach. Both defects were filled with particulate autogenous bone from tuber and covered with resorbable collagen membrane. The follow-up of 30 and 13 months of the implants 24 and 14, respectively, showed an absence of clinical signs of periimplant inflammation and near-complete bone regeneration. The therapy approach was effective in eliminating periimplant inflammation and promoting bone gain around the implants.

  15. Osteodistraction With Dental Implant-Borne Devices for Bone Regeneration in Atrophied Premaxilla.

    PubMed

    Carlino, Francesco; Villani, Gian Piero; Berti, Andrea; Pantaleo, Giuseppe; Cortese, Antonio; Claudio, Pier Paolo

    2016-11-01

    Aim of this work is to present the evolution of an innovative technique for tooth/implant supported bone distraction, leading to proper oral rehabilitation in patients with atrophic alveolar bone, even when a complete premaxilla expansion is needed, or in patients in whom implants were already present, but inserted in wrong position.Distraction osteogenesis was selected because of its moderate invasiveness, the few surgical steps needed, and the proper cost/benefits balance. This procedure is particularly suited for young patients with remarkable aesthetic demands related to active social and working life, as for elderly patients expecting lower surgical stress and risks.

  16. Alveolar bone regeneration for immediate implant placement using an injectable bone substitute: an experimental study in dogs.

    PubMed

    Boix, Damien; Gauthier, Olivier; Guicheux, Jérôme; Pilet, Paul; Weiss, Pierre; Grimandi, Gaël; Daculsi, Guy

    2004-05-01

    The aim of the present study was to assess the efficacy of a ready-to-use injectable bone substitute for bone regeneration around dental implants placed into fresh extraction sockets. Third and fourth mandibular premolars were extracted from three beagle dogs and the interradicular septa were surgically reduced to induce a mesial bone defect. Thereafter, titanium implants were immediately placed. On the left side of the jaw, mesial bone defects were filled with an injectable bone substitute (IBS), obtained by combining a polymer and biphasic calcium phosphate ceramic granules. The right defects were left unfilled as controls. After 3 months of healing, specimens were prepared for histological and histomorphometric evaluations. No post-surgical complications were observed during the healing period. In all experimental conditions, histological observations revealed a lamellar bone formation in contact with the implant. Histomorphometric analysis showed that IBS triggers a significant (P<0.05) increase in terms of the number of threads in contact with bone, bone-to-implant contact, and peri-implant bone density of approximately 8.6%, 11.0%, and 14.7%, respectively. In addition, no significant difference was observed when number of threads, bone-to-implant contact, and bone density in the filled defects were compared to the no-defect sites. It is concluded that an injectable bone substitute composed of a polymeric carrier and calcium phosphate significantly increases bone regeneration around immediately placed implants.

  17. Surgical Treatment of Traumatic Myositis Ossificans of the Extensor Carpi Radialis Muscle in a Dog.

    PubMed

    Morton, Bridget A; Hettlich, Bianca F; Pool, Roy R

    2015-07-01

    To report clinical signs, diagnostic imaging findings, and outcome in a dog with traumatic myositis ossificans of the origin of the extensor carpi radialis muscle. Clinical report. An 8-month-old intact female Irish Setter Dog. After radiographic and computed tomographic evaluation of an osseous proliferation arising from the cranial cortex of the right distal humeral diaphysis, the protruding bone was surgically removed and evaluated by histopathology. Traumatic myositis ossificans was successfully treated with surgical removal of the osseous proliferation resulting in improved postoperative range of motion of the right elbow joint. There was no evidence of lameness or abnormal bone regrowth associated with the surgical site radiographically at follow up. Surgical removal of a traumatic myositis ossificans lesion resulted in full return to function in a young, competitive show dog. © Copyright 2014 by The American College of Veterinary Surgeons.

  18. Clubfoot repair

    MedlinePlus

    ... need include: Osteotomy : Removing part of the bone. Fusion or arthrodesis : Two or more bones are fused ... Patient Instructions Preventing falls Surgical wound care - open Images Clubfoot repair - series References Kelly DM. Congenital anomalies ...

  19. Cervical Laminoplasty

    MedlinePlus

    ... Medicine Acupuncture Herbal Supplements Surgical Options Anterior Cervical Fusion Artifical Disc Replacement (ADR) Bone Graft Alternatives Bone ... Percutaneous Vertebral Augmentation (PVA) Posterior Cervical Foraminotomy Spinal ... Nonsurgical Treatments Activity Modification Chiropractic – A Conversation with ...

  20. Use of 3D Printed Bone Plate in Novel Technique to Surgically Correct Hallux Valgus Deformities

    PubMed Central

    Smith, Kathryn E.; Dupont, Kenneth M.; Safranski, David L.; Blair, Jeremy; Buratti, Dawn; Zeetser, Vladimir; Callahan, Ryan; Lin, Jason; Gall, Ken

    2016-01-01

    Three-dimensional (3-D) printing offers many potential advantages in designing and manufacturing plating systems for foot and ankle procedures that involve small, geometrically complex bony anatomy. Here, we describe the design and clinical use of a Ti-6Al-4V ELI bone plate (FastForward™ Bone Tether Plate, MedShape, Inc., Atlanta, GA) manufactured through 3-D printing processes. The plate protects the second metatarsal when tethering suture tape between the first and second metatarsals and is a part of a new procedure that corrects hallux valgus (bunion) deformities without relying on doing an osteotomy or fusion procedure. The surgical technique and two clinical cases describing the use of this procedure with the 3-D printed bone plate are presented within. PMID:28337049

  1. Patient-specific instrument can achieve same accuracy with less resection time than navigation assistance in periacetabular pelvic tumor surgery: a cadaveric study.

    PubMed

    Wong, Kwok-Chuen; Sze, Kwan-Yik; Wong, Irene Oi-Ling; Wong, Chung-Ming; Kumta, Shekhar-Madhukar

    2016-02-01

    Inaccurate resection in pelvic tumors can result in compromised margins with increase local recurrence. Navigation-assisted and patient-specific instrument (PSI) techniques have recently been reported in assisting pelvic tumor surgery with the tendency of improving surgical accuracy. We examined and compared the accuracy of transferring a virtual pelvic resection plan to actual surgery using navigation-assisted or PSI technique in a cadaver study. We performed CT scan in twelve cadaveric bodies including whole pelvic bones. Either supraacetabular or partial acetabular resection was virtually planned in a hemipelvis using engineering software. The virtual resection plan was transferred to a CT-based navigation system or was used for design and fabrication of PSI. Pelvic resections were performed using navigation assistance in six cadavers and PSI in another six. Post-resection images were co-registered with preoperative planning for comparative analysis of resection accuracy in the two techniques. The mean average deviation error from the planned resection was no different ([Formula: see text]) for the navigation and the PSI groups: 1.9 versus 1.4 mm, respectively. The mean time required for the bone resection was greater ([Formula: see text]) for the navigation group than for the PSI group: 16.2 versus 1.1 min, respectively. In simulated periacetabular pelvic tumor resections, PSI technique enabled surgeons to reproduce the virtual surgical plan with similar accuracy but with less bone resection time when compared with navigation assistance. Further studies are required to investigate the clinical benefits of PSI technique in pelvic tumor surgery.

  2. Simulation in Surgical Education

    PubMed Central

    de Montbrun, Sandra L.; MacRae, Helen

    2012-01-01

    The pedagogical approach to surgical training has changed significantly over the past few decades. No longer are surgical skills solely acquired through a traditional apprenticeship model of training. The acquisition of many technical and nontechnical skills is moving from the operating room to the surgical skills laboratory through the use of simulation. Many platforms exist for the learning and assessment of surgical skills. In this article, the authors provide a broad overview of some of the currently available surgical simulation modalities including bench-top models, laparoscopic simulators, simulation for new surgical technologies, and simulation for nontechnical surgical skills. PMID:23997671

  3. Mid- and long-term clinical results of surgical therapy in unicameral bone cysts.

    PubMed

    Hagmann, Sébastien; Eichhorn, Florian; Moradi, Babak; Gotterbarm, Tobias; Dreher, Thomas; Lehner, Burkhard; Zeifang, Felix

    2011-12-13

    Unicameral (or simple) bone cysts (UBC) are benign tumours most often located in long bones of children and adolescents. Pathological fractures are common, and due to high recurrence rates, these lesions remain a challenge to treat. Numerous surgical procedures have been proposed, but there is no general consensus of the ideal treatment. The aim of this investigation therefore was to study the long-term outcome after surgical treatment in UBC. A retrospective analysis of 46 patients surgically treated for UBC was performed for short and mid-term outcome. Clinical and radiological outcome parameters were studied according to a modified Neer classification system. Long-term clinical information was retrieved via a questionnaire at a minimum follow-up of 10 years after surgery. Forty-six patients (17 female, 29 male) with a mean age of 10.0 ± 4.8 years and with histopathologically confirmed diagnosis of UBC were included. Pathological fractures were observed in 21 cases (46%). All patients underwent surgery for UBC (35 patients underwent curettage and bone grafting as a primary therapy, 4 curettage alone, 3 received corticoid instillation and 4 decompression by cannulated screws). Overall recurrence rate after the first surgical treatment was 39% (18/46), second (17.4% of all patients) and third recurrence (4.3%) were frequently observed and were addressed by revision surgery. Recurrence was significantly higher in young and in male patients as well as in active cysts. After a mean of 52 months, 40 out of 46 cysts were considered healed. Prognosis was significantly better when recurrence was observed later than 30 months after therapy. After a mean follow-up of 15.5 ± 6.2 years, 40 patients acknowledged clinically excellent results, while five reported mild and casual pain. Only one patient reported a mild limitation of range of motion. Our results suggest satisfactory overall long-term outcome for the surgical treatment of UBC, although short-and mid-term observation show a considerable rate of recurrence independent of the surgical technique.

  4. Review of 3-Dimensional Printing on Cranial Neurosurgery Simulation Training.

    PubMed

    Vakharia, Vejay N; Vakharia, Nilesh N; Hill, Ciaran S

    2016-04-01

    Shorter working times, reduced operative exposure to complex procedures, and increased subspecialization have resulted in training constraints within most surgical fields. Simulation has been suggested as a possible means of acquiring new surgical skills without exposing patients to the surgeon's operative "learning curve." Here we review the potential impact of 3-dimensional printing on simulation and training within cranial neurosurgery and its implications for the future. In accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, a comprehensive search of PubMed, OVID MEDLINE, Embase, and the Cochrane Database of Systematic Reviews was performed. In total, 31 studies relating to the use of 3-dimensional (3D) printing within neurosurgery, of which 16 were specifically related to simulation and training, were identified. The main impact of 3D printing on neurosurgical simulation training was within vascular surgery, where patient-specific replication of vascular anatomy and pathologies can aid surgeons in operative planning and clip placement for reconstruction of vascular anatomy. Models containing replicas of brain tumors have also been reconstructed and used for training purposes, with some providing realistic representations of skin, subcutaneous tissue, bone, dura, normal brain, and tumor tissue. 3D printing provides a unique means of directly replicating patient-specific pathologies. It can identify anatomic variation and provide a medium in which training models can be generated rapidly, allowing the trainee and experienced neurosurgeon to practice parts of operations preoperatively. Future studies are required to validate this technology in comparison with current simulators and show improved patient outcomes. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Teaching basic trauma: validating FluoroSim, a digital fluoroscopic simulator for guide-wire insertion in hip surgery.

    PubMed

    Sugand, Kapil; Wescott, Robert A; Carrington, Richard; Hart, Alister; Van Duren, Bernard H

    2018-05-10

    Background and purpose - Simulation is an adjunct to surgical education. However, nothing can accurately simulate fluoroscopic procedures in orthopedic trauma. Current options for training with fluoroscopy are either intraoperative, which risks radiation, or use of expensive and unrealistic virtual reality simulators. We introduce FluoroSim, an inexpensive digital fluoroscopy simulator without the need for radiation. Patients and methods - This was a multicenter study with 26 surgeons in which everyone completed 1 attempt at inserting a guide-wire into a femoral dry bone using surgical equipment and FluoroSim. 5 objective performance metrics were recorded in real-time to assess construct validity. The surgeons were categorized based on the number of dynamic hip screws (DHS) performed: novices (< 10), intermediates (10-39) and experts (≥ 40). A 7-point Likert scale questionnaire assessed the face and content validity of FluoroSim. Results - Construct validity was present for 2 clinically validated metrics in DHS surgery. Experts and intermediates statistically significantly outperformed novices for tip-apex distance and for cut-out rate. Novices took the least number of radiographs. Face and content validity were also observed. Interpretation - FluoroSim discriminated between novice and intermediate or expert surgeons based on tip-apex distance and cut-out rate while demonstrating face and content validity. FluoroSim provides a useful adjunct to orthopedic training. Our findings concur with results from studies using other simulation modalities. FluoroSim can be implemented for education easily and cheaply away from theater in a safe and controlled environment.

  6. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures.

    PubMed

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS.

  7. The Photodynamic Bone Stabilization System: a minimally invasive, percutaneous intramedullary polymeric osteosynthesis for simple and complex long bone fractures

    PubMed Central

    Vegt, Paul; Muir, Jeffrey M; Block, Jon E

    2014-01-01

    The treatment of osteoporotic long bone fractures is difficult due to diminished bone density and compromised biomechanical integrity. The majority of osteoporotic long bone fractures occur in the metaphyseal region, which poses additional problems for surgical repair due to increased intramedullary volume. Treatment with internal fixation using intramedullary nails or plating is associated with poor clinical outcomes in this patient population. Subsequent fractures and complications such as screw pull-out necessitate additional interventions, prolonging recovery and increasing health care costs. The Photodynamic Bone Stabilization System (PBSS) is a minimally invasive surgical technique that allows clinicians to repair bone fractures using a light-curable polymer contained within an inflatable balloon catheter, offering a new treatment option for osteoporotic long bone fractures. The unique polymer compound and catheter application provides a customizable solution for long bone fractures that produces internal stability while maintaining bone length, rotational alignment, and postsurgical mobility. The PBSS has been utilized in a case series of 41 fractures in 33 patients suffering osteoporotic long bone fractures. The initial results indicate that the use of the light-cured polymeric rod for this patient population provides excellent fixation and stability in compromised bone, with a superior complication profile. This paper describes the clinical uses, procedural details, indications for use, and the initial clinical findings of the PBSS. PMID:25540600

  8. Patient-specific model of a scoliotic torso for surgical planning

    NASA Astrophysics Data System (ADS)

    Harmouche, Rola; Cheriet, Farida; Labelle, Hubert; Dansereau, Jean

    2013-03-01

    A method for the construction of a patient-specific model of a scoliotic torso for surgical planning via inter-patient registration is presented. Magnetic Resonance Images (MRI) of a generic model are registered to surface topography (TP) and X-ray data of a test patient. A partial model is first obtained via thin-plate spline registration between TP and X-ray data of the test patient. The MRIs from the generic model are then fit into the test patient using articulated model registration between the vertebrae of the generic model's MRIs in prone position and the test patient's X-rays in standing position. A non-rigid deformation of the soft tissues is performed using a modified thin-plate spline constrained to maintain bone rigidity and to fit in the space between the vertebrae and the surface of the torso. Results show average Dice values of 0:975 +/- 0:012 between the MRIs following inter-patient registration and the surface topography of the test patient, which is comparable to the average value of 0:976 +/- 0:009 previously obtained following intra-patient registration. The results also show a significant improvement compared to rigid inter-patient registration. Future work includes validating the method on a larger cohort of patients and incorporating soft tissue stiffness constraints. The method developed can be used to obtain a geometric model of a patient including bone structures, soft tissues and the surface of the torso which can be incorporated in a surgical simulator in order to better predict the outcome of scoliosis surgery, even if MRI data cannot be acquired for the patient.

  9. Effects of plantar fascia stiffness on the biomechanical responses of the ankle-foot complex.

    PubMed

    Cheung, Jason Tak-Man; Zhang, Ming; An, Kai-Nan

    2004-10-01

    The plantar fascia is one of the major stabilizing structures of the longitudinal arch of human foot, especially during midstance of the gait cycle. Knowledge of its functional biomechanics is important for establishing the biomechanical rationale behind different rehabilitation, orthotic and surgical treatment of plantar fasciitis. This study aims at quantifying the biomechanical responses of the ankle-foot complex with different plantar fascia stiffness. A geometrical detailed three-dimensional finite element model of the human foot and ankle, incorporating geometric and contact nonlinearities was constructed by 3D reconstruction of MR images. A sensitivity study was conducted to evaluate the effects of varying elastic modulus (0-700 MPa) of the plantar fascia on the stress/strain distribution of the bony, ligamentous and encapsulated soft tissue structures. The results showed that decreasing the Young's modulus of plantar fascia would increase the strains of the long and short plantar and spring ligaments significantly. With zero fascia Young's modulus to simulate the plantar fascia release, there was a shift in peak von Mises stresses from the third to the second metatarsal bones and increased stresses at the plantar ligament attachment area of the cuboid bone. Decrease in arch height and midfoot pronation were predicted but did not lead to the total collapse of foot arch. Surgical dissection of the plantar fascia may induce excessive strains or stresses in the ligamentous and bony structures. Surgical release of plantar fascia should be well-planned to minimise the effect on its structural integrity to reduce the risk of developing arch instability and subsequent painful foot syndrome.

  10. Contemporary Medical and Surgical Management of X-linked Hypophosphatemic Rickets.

    PubMed

    Sharkey, Melinda S; Grunseich, Karl; Carpenter, Thomas O

    2015-07-01

    X-linked hypophosphatemia is an inheritable disorder of renal phosphate wasting that clinically manifests with rachitic bone pathology. X-linked hypophosphatemia is frequently misdiagnosed and mismanaged. Optimized medical therapy is the cornerstone of treatment. Even with ideal medical management, progressive bony deformity may develop in some children and adults. Medical treatment is paramount to the success of orthopaedic surgical procedures in both children and adults with X-linked hypophosphatemia. Successful correction of complex, multiapical bone deformities found in patients with X-linked hypophosphatemia is possible with careful surgical planning and exacting surgical technique. Multiple methods of deformity correction are used, including acute and gradual correction. Treatment of some pediatric bony deformity with guided growth techniques may be possible. Copyright 2015 by the American Academy of Orthopaedic Surgeons.

  11. [The effect of pre-surgical orthodontics on secondary alveolar bone grafting in the patients with complete cleft lip and palate].

    PubMed

    Jia, Yi-lin; Fu, Min-kui; Ma, Lian

    2004-05-01

    To examine the effect of pre-surgical orthodontics on the outcome of the secondary alveolar bone grafting in the patients with complete cleft lip and palate. Sixteen complete cleft lip and palate patients (9 males and 7 females) with collapsed upper arch or severe mal-positioned upper incisors were selected. The cleft was not easily grafted because of the poor access. The total cleft sites were 22 (10 patients with UCLP and 6 patients with BCLP). The age range of the patients was from 8 to 22 years. Pre-surgical orthodontic treatment was mainly to expand the collapsed upper arch and correct the mal-positioned upper incisors. After the secondary alveolar bone grafting, the patients were followed up and anterior occlusal radiograph/intraoral panograph were taken regularly. The observation period was from 6 months to 4 years. Bergland criteria were used to evaluate the interdental septal height. Upper arch expansion and the correction of the mal-positioned upper incisors done by the orthodontic treatment made the bone grafting procedure easier. The clinically successful rate reached 86%. The severe upper arch collapse and mal-positioned upper incisors in the patients with complete cleft lip and palate should be corrected orthodontically before the secondary alveolar bone grafting.

  12. Surgical Treatment of Bone Marrow Lesion Associated with Recurrent Plantar Fasciitis: A Case Report Describing an Innovative Technique Using Subchondroplasty®.

    PubMed

    Bernhard, Kaitlyn; Ng, Alan; Kruse, Dustin; Stone, Paul A

    2018-04-06

    Plantar fasciitis is one of the most common chief complaints seen in the foot and ankle clinic. With a relatively benign course, most cases are self-limiting or amendable to conservative therapy; ~90% of all plantar fasciitis cases will respond to these methods. When conservative treatment and time fail, surgical intervention can be necessary to improve outcomes. We present a novel method using Subchondroplasty ® (SCP ® ; Zimmer Holdings, Inc.; Warsaw, IN) and revision fasciotomy in a case in which initial fasciotomy had failed. After the patient had failed to improve, a worsening underlying bone marrow lesion was identified at the origin of the plantar fascia; thus, SCP ® was used with repeat fasciotomy. SCP ® involves injecting calcium phosphate into bone marrow lesions to stimulate long-term bone repair. At 10 months after SCP ® , the patient remained pain free and had returned to running at the final follow-up examination. This surgical treatment should be considered as an adjunctive procedure for those patients with plantar fasciitis, identifiable bone marrow lesions on magnetic resonance imaging, and continued pain when other treatment modalities have failed. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. Laser bioengineering of glass-titanium implants surface

    NASA Astrophysics Data System (ADS)

    Lusquiños, F.; Arias-González, F.; Penide, J.; del Val, J.; Comesaña, R.; Quintero, F.; Riveiro, A.; Boutinguiza, M.; Pascual, M. J.; Durán, A.; Pou, J.

    2013-11-01

    Osseointegration is the mean challenge when surgical treatments fight against load-bearing bone diseases. Absolute bone replacement by a synthetic implant has to be completed not only from the mechanics point of view, but also from a biological approach. Suitable strength, resilience and stress distribution of titanium alloy implants are spoiled by the lack of optimal biological characteristics. The inert quality of extra low interstitial titanium alloy, which make it the most attractive metallic alloy for biomedical applications, oppose to an ideal surface with bone cell affinity, and capable to stimulate bone attachment bone growth. Diverse laser treatments have been proven as effective tools to modify surface properties, such as wettability in contact to physiological fluids, or osteoblast guided and slightly enhanced attachment. The laser surface cladding can go beyond by providing titanium alloy surfaces with osteoconduction and osteoinduction properties. In this research work, the laser radiation is used to produce bioactive glass coatings on Ti6Al4V alloy substrates. Specific silicate bioactive glass compositions has been investigated to achieve suitable surface tension and viscosity temperature behavior during processing, and to provide with the required release of bone growth gene up regulation agents in the course of resorption mediated by physiological fluids. The produced coatings and interfaces, the surface osteoconduction properties, and the chemical species release in simulated physiological fluid were characterized by scanning electron microscopy (SEM), hot stage microscopy (HSM), X-ray diffraction (XRD), X ray fluorescence (XRF), and Fourier transform infrared spectroscopy (FTIR).

  14. Malunion of Long-Bone Fractures in a Conflict Zone in the Democratic Republic of Congo.

    PubMed

    Bauhahn, Grace; Veen, Harald; Hoencamp, Rigo; Olim, Nelson; Tan, Edward C T H

    2017-09-01

    Malunion is a well-recognized complication of long-bone fractures which accounts for more than 25% of injuries in conflict zones. The aim of this study was to investigate the rate of malunion sustained by casualties with penetrating gunshot wounds in an International Committee of the Red Cross (ICRC) surgical substitution project in the Democratic Republic of Congo (DRC) and compare these results with current literature. A retrospective cohort study was performed. All patients admitted to the ICRC facility between the periods of 01.10.2014 and 31.12.2015 with long-bone fractures caused by gunshot wound were included, and data were collected retrospectively from the patient's hospital notes. A total of 191 fractures caused by gunshot were treated in the DRC at the ICRC surgical substitution project during the study period. On average, the fractures were 3 days old on admission and were all open, with 62% also being comminuted. The ICRC management protocol, which emphasizes debridement, antibiotic prophylaxis and conservative fracture stabilization, was followed in all cases. Forty-eight percentage of the fractures were finally classified as 'union without complication'; however, 17% were classified as 'malunion'. This study indicates that open long-bone fractures that are managed by the ICRC surgical substitution project in DRC may have an increased likelihood of malunion as compared to long-bone fractures treated in developed countries. Patient delay and mechanism of injury may have caused increased rates of infection which are likely behind these increased rates of malunion, alongside the lack of definitive fracture treatment options made available to the surgical team.

  15. 3D Printed Pediatric Temporal Bone: A Novel Training Model.

    PubMed

    Longfield, Evan A; Brickman, Todd M; Jeyakumar, Anita

    2015-06-01

    Temporal bone dissection is a fundamental element of otologic training. Cadaveric temporal bones (CTB) are the gold standard surgical training model; however, many institutions do not have ready access to them and their cost can be significant: $300 to $500. Furthermore, pediatric cadaveric temporal bones are not readily available. Our objective is to develop a pediatric temporal bone model. Temporal bone model. Tertiary Children's Hospital. Pediatric patient model. We describe the novel use of a 3D printer for the generation of a plaster training model from a pediatric high- resolution CT temporal bone scan of a normal pediatric temporal bone. Three models were produced and were evaluated. The models utilized multiple colors (white for bone, yellow for the facial nerve) and were of high quality. Two models were drilled as a proof of concept and found to be an acceptable facsimile of the patient's anatomy, rendering all necessary surgical landmarks accurately. The only negative comments pertaining to the 3D printed temporal bone as a training model were the lack of variation in hardness between cortical and cancellous bone, noting a tactile variation from cadaveric temporal bones. Our novel pediatric 3D temporal bone training model is a viable, low-cost training option for previously inaccessible pediatric temporal bone training. Our hope is that, as 3D printers become commonplace, these models could be rapidly reproduced, allowing for trainees to print models of patients before performing surgery on the living patient.

  16. Ossified Intracranial Meningiomas: Description of the First Series of Cases and Review of the Literature.

    PubMed

    Caffo, Maria; Caruso, Gerardo; Barresi, Valeria; Tomasello, Francesco

    2016-10-01

    Metaplastic meningiomas are characterized by mesenchymal differentiation with formation of bone, cartilage, fat, or xanthomatous elements. However the presence of extensive areas of ossification is rare in meningiomas. In addition, intracranial location of ossified meningiomas is uncommon. Surgical management represents the optimal treatment for ossified meningiomas, but ossification may interfere with surgery and condition outcome. By reviewing patient records and contacting patients, families, and referring physicians, the following information was gathered: age, sex, tumor location, clinical presentation, preoperative and postoperative functional status, and surgical data. Each surgical specimen had been formalin-fixed, paraffin-embedded, and cut into parallel 4-μm-thick sections for histological evaluation. Our literature search identified 8 cases, all of whom had undergone surgical treatment. Histopathological analysis revealed the presence of disorganized bone spicules with solitary oval osteocytic nuclei and lined by osteoblasts, with clear evidence of bone tissue in at least 50% of tumor tissue. Here we present the largest series, to our knowledge, of surgically treated intracranial ossified meningiomas reported to date. The mechanism of ossification in these meningiomas remains unclear, and various hypotheses have been formulated. Complete lesion removal, or subtotal debulking in those cases characterized by tenacious adherences to vascular structures and/or critical areas, may represent the optimal treatment. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Rotary ultrasonic drilling on bone: A novel technique to put an end to thermal injury to bone.

    PubMed

    Gupta, Vishal; Pandey, Pulak M; Gupta, Ravi K; Mridha, Asit R

    2017-03-01

    Bone drilling is common in orthopedic procedures and the heat produced during conventional experimental drilling often exceeds critical temperature of 47 °C and induces thermal osteonecrosis. The osteonecrosis may be the reason for impaired healing, early loosening and implant failure. This study was undertaken to control the temperature rise by interrupted cutting and reduced friction effects at the interface of drill tool and the bone surface. In this work, rotary ultrasonic drilling technique with diamond abrasive particles coated on the hollow drill tool without any internal or external cooling assistance was used. Experiments were performed at room temperature on the mid-diaphysis sections of fresh pig bones, which were harvested immediately after sacrifice of the animal. Both rotary ultrasonic drilling on bone and conventional surgical drilling on bone were performed in a five set of experiments on each process using identical constant process parameters. The maximum temperature of each trial was recorded by K-type thermocouple device. Ethylenediaminetetraacetic acid decalcification was done for microscopic examination of bone. In this comparative procedure, rotary ultrasonic drilling on bone produced much lower temperature, that is, 40.2 °C ± 0.4 °C and 40.3 °C ± 0.2 °C as compared to that of conventional surgical drilling on bone, that is, 74.9 °C ± 0.8 °C and 74.9 °C ± 0.6 °C with respect to thermocouples fixed at first and second position, respectively. The conventional surgical drilling on bone specimens revealed gross tissue burn, microscopic evidence of thermal osteonecrosis and tissue injury in the form of cracks due to the generated force during drilling. But our novel technique showed no such features. Rotary ultrasonic drilling on bone technique is robust and superior to other methods for drilling as it induces no thermal osteonecrosis and does not damage the bone by generating undue forces during drilling.

  18. A Retrospective Case Series of Surgical Implant Generation Network (SIGN) Placement at the Afghan National Police Hospital, Kabul, Afghanistan.

    PubMed

    Ertl, Christian W; Royal, David; Arzoiey, Humayoon Abdul; Shefa, Azizullah; Sultani, Salim; Mosafa, Mohammed Omar; Sadat, Safiullah; Zirkle, Lewis

    2016-01-01

    In Afghanistan, adequate and cost-effective medical care for even routine conditions is lacking; especially for complex injuries like long-bone fractures. The Surgical Implant Generation Network (SIGN) intramedullary nail is used for treatment of long-bone fractures from blunt injuries and does not require imaging. We are reporting for the first time results of the SIGN intramedullary nail at the Afghan National Police Hospital, a tertiary care facility in Kabul. 71 records from the SIGN Online Surgical Database were reviewed for gender, age, date of injury, implant date, patient's home of record, and type/ mechanism of injury. Mean age was 26.7 years, all but one being male; time from injury to implant ranged 1 to 401 days, with mean of 40.6 days. Long-bone fractures from motor vehicle accidents remained constant, and war injuries peaked in summer. Follow-up is limited because of security and financial burdens of travel. However, personal communication with Afghan National Police Hospital surgeons suggests that patients included in the current study have not experienced any adverse outcomes. While it remains to be seen if the SIGN Online Surgical Database will facilitate more comprehensive outcome studies, our results provide support for the efficacy of SIGN nails in treating long-bone fractures from war injuries. Reprint & Copyright © 2016 Association of Military Surgeons of the U.S.

  19. An oxidized implant surface may improve bone-to-implant contact in pristine bone and bone defects treated with guided bone regeneration: an experimental study in dogs.

    PubMed

    Gurgel, Bruno César de Vasconcelos; Gonçalves, Patrícia Furtado; Pimentel, Suzana Peres; Nociti, Francisco Humberto; Sallum, Enilson Antonio; Sallum, Antonio Wilson; Casati, Marcio Zaffalon

    2008-07-01

    The aim of the present study was to histometrically evaluate bone healing in the absence of bone defects and in the presence of surgically created bone defects treated by guided bone regeneration at oxidized and turned implant surfaces. Three months after dental extractions, standardized buccal dehiscence defects (height: 5 mm; width: 4 mm) were surgically created following implant site preparation in the mandible of 10 dogs. Oxidized-surface implants (OSI) and turned-surface implants (TSI) were inserted bilaterally, and the bone defects were treated by guided bone regeneration. After 3 months of healing, the animals were sacrificed, blocks were dissected, and undecalcified sections were obtained and processed for histometric analysis. The percentage of bone-to-implant contact (BIC) and bone density (BD) was evaluated inside the threads on the buccal (regenerated bone) and lingual sides (pristine bone) of the implants. Data were evaluated using two-way analysis of variance (P <0.05). New bone formation could be observed in OSI and TSI in the region of the defect creation. The BIC values observed in OSI for pristine and regenerated bone were 57.03% +/- 21.86% and 40.86% +/- 22.73%, respectively. TSI showed lower values of BIC in pristine bone (37.39% +/- 23.33%) and regenerated bone (3.52% +/- 4.87%). The differences between OSI and TSI were statistically significant. BD evaluation showed no statistically significant differences between OSI and TSI in pristine and regenerated bone. The oxidized implant surface promoted a higher level of BIC than the turned implant surface at pristine and regenerated bone.

  20. Cuboid oedema due to peroneus longus tendinopathy: a report of four cases.

    PubMed

    O'Donnell, Paul; Saifuddin, Asif

    2005-07-01

    To highlight focal bone abnormality in the cuboid due to tendinopathy of the adjacent peroneus longus. A retrospective review was carried out of the relevant clinical and imaging features. Two male and two female patients were studied, mean age 51.5 years (range 32-67 years), referred with foot pain and imaging showing an abnormal cuboid thought to represent either tumour or infection. A long history of foot pain was usual with a maximum of 8 years. Radiographs were normal in two cases and showed erosion in two, one of which exhibited periosteal new bone formation affecting the cuboid. Bone scintigraphy was undertaken in two patients, both of whom showed increased uptake of isotope. MRI, performed in all patients, showed oedema in the cuboid adjacent to the peroneus longus tendon. The tendon and/or paratendinous tissues were abnormal in all cases, but no tendon discontinuity was identified. One patient possessed an os peroneum. Unequivocal evidence of bone erosion was seen using MRI in three patients, but with greater clarity in two cases using CT. Additional findings of tenosynovitis of tibialis posterior, oedema in the adjacent medial malleolus and synovitis of multiple joints in the foot were seen in one patient. Imaging diagnosis was made in all cases avoiding bone biopsy, but surgical exploration of the peroneal tendons was performed in two cases and biopsy of ankle synovium in one. Oedema with erosion of the cuboid bone, simulating a bone lesion (cuboid "pseudotumour"), may be caused by adjacent tendinopathy of peroneus longus. It is vital to be aware of this entity to avoid unnecessary biopsy of the cuboid.

  1. Exercise Countermeasures for Bone Loss During Space Flight: A Method for the Study of Ground Reaction Forces and their Implications for Bone Strain

    NASA Technical Reports Server (NTRS)

    Peterman, M.; McCrory, J. L.; Sharkey, N. A.; Piazza, S.; Cavanagh, P. R.

    1999-01-01

    Effective countermeasures to prevent loss of bone mineral during long duration space flight remain elusive. Despite an exercise program on MIR flights, the data from LeBlanc et al. (1996) indicated that there was still a mean rate of loss of bone mineral density in the proximal femur of 1.58% per month (n=18, flight duration 4 - 14.4 months). The specific mechanisms regulating bone mass are not known, but most investigators agree that bone maintenance is largely dependent upon mechanical demand and the resultant local bone strains. A plausible hypothesis is that bone loss during space flight, such as that reported by LeBlanc et al. (1996), may result from failure to effectively load the skeleton in order to generate localized bone strains of sufficient magnitude to prevent disuse osteoporosis. A variety of methods have been proposed to simulate locomotor exercise in reduced gravity. In such simulations, and in an actual microgravity environment, a gravity replacement load (GRL) must always be added to return the exercising subject to the support surface and the resulting skeletal load is critically dependent upon the magnitude of the GRL. To our knowledge, GRLs during orbital flight have only been measured once (on STS 81) and it is likely that most or all prior treadmill exercise in space has used GRLs that were less than one body weight. McCrory (1997) has shown that subjects walking and running in simulated zero-G can tolerate GRLs of 1 if an appropriate harness is used. Several investigators have attempted to measure in vivo strains and forces in the bones of humans, but have faced ethical and technical limitations. The anteromedial aspect of the tibial midshaft has been a common site for the placement of strain gauges; one reason to measure strains in the anterior tibia is that this region is surgically accessible. Aamodt et al. (1997) were able to measure strains on the lateral surface of the proximal femur only because their experimental subjects were already scheduled for hip surgery. Lu et al. (1997) used an instrumented massive proximal femoral prosthesis along with electromyographic measurements to demonstrate that femoral forces depend on muscular activity. These analyses of in vivo bone mechanics are valuable. The invasive nature of the procedures involved, however, limits both the number of subjects and the number of strain gauge locations. Further, the results of these studies may be confounded by the inclusion of subjects with pathological conditions. Gross et al. (1992) measured strain at three locations on the equine third metacarpal and used those data to construct a computer model of the internal strain environment of the bone. An analogous placement of multiple gauges in living humans would be difficult and potentially hazardous because of the depth of soft tissue overlying the tibia and femur.

  2. Incorporating simulation into gynecologic surgical training.

    PubMed

    Wohlrab, Kyle; Jelovsek, J Eric; Myers, Deborah

    2017-11-01

    Today's educational environment has made it more difficult to rely on the Halstedian model of "see one, do one, teach one" in gynecologic surgical training. There is decreased surgical volume, but an increased number of surgical modalities. Fortunately, surgical simulation has evolved to fill the educational void. Whether it is through skill generalization or skill transfer, surgical simulation has shifted learning from the operating room back to the classroom. This article explores the principles of surgical education and ways to introduce simulation as an adjunct to residency training. We review high- and low-fidelity surgical simulators, discuss the progression of surgical skills, and provide options for skills competency assessment. Time and money are major hurdles when designing a simulation curriculum, but low-fidelity models, intradepartmental cost sharing, and utilizing local experts for simulation proctoring can aid in developing a simulation program. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Primary telangiectatic osteosarcoma of occipital bone: a case report and review of literature.

    PubMed

    Patibandla, Mohana Rao; Uppin, Shantveer G; Thotakura, Amit Kumar; Panigrahi, Manas K; Challa, Sundaram

    2011-01-01

    Telangiectatic osteosarcoma (TOS), an uncommon variant of osteosarcoma, involving skull bones is extremely rare. We present clinico-pathological, imageological and treatment outcome of a primary TOS of occipital bone in a 30-year-old woman and review the previously reported skull bone TOS. We suggest that TOS should be included in the differential diagnosis of destructive lytic lesions involving the skull bones. As radical surgical procedures are not applicable to skull bones, the outcome is poor even with adjuvant chemotherapy.

  4. Method of adhering bone to a rigid substrate using a graphite fiber reinforced bone cement

    NASA Technical Reports Server (NTRS)

    Knoell, A. C.; Maxwell, H. G. (Inventor)

    1977-01-01

    A method is described for adhering bone to the surface of a rigid substrate such as a metal or resin prosthesis using an improved surgical bone cement. The bone cement has mechanical properties more nearly matched to those of animal bone and thermal curing characteristics which result in less traumatization of body tissues and comprises a dispersion of short high modulus graphite fibers within a bonder composition including polymer dissolved in reactive monomer such as polymethylmethacrylate dissolved in methylmethacrylate monomer.

  5. 21 CFR 872.4770 - Temporary mandibular condyle reconstruction plate.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... device that is intended to stabilize mandibular bone and provide for temporary reconstruction of the... surgical procedures requiring removal of the mandibular condyle and mandibular bone. This device is not...

  6. BONE REGENERATION AFTER DEMINERALIZED BONE MATRIX AND CASTOR OIL (RICINUS COMMUNIS) POLYURETHANE IMPLANTATION

    PubMed Central

    Leite, Fábio Renato Manzolli; Ramalho, Lizeti Toledo de Oliveira

    2008-01-01

    Innocuous biocompatible materials have been searched to repair or reconstruct bone defects. Their goal is to restore the function of live or dead tissues. This study compared connective tissue and bone reaction when exposed to demineralized bovine bone matrix and a polyurethane resin derived from castor bean (Ricinus communis). Forty-five rats were assigned to 3 groups of 15 animals (control, bovine bone and polyurethane). A cylindrical defect was created on mandible base and filled with bovine bone matrix and the polyurethane. Control group received no treatment. Analyses were performed after 15, 45 and 60 days (5 animals each). Histological analysis revealed connective tissue tolerance to bovine bone with local inflammatory response similar to that of the control group. After 15 days, all groups demonstrated similar outcomes, with mild inflammatory reaction, probably due to the surgical procedure rather than to the material. In the polymer group, after 60 days, scarce multinucleated cells could still be observed. In general, all groups showed good stability and osteogenic connective tissue with blood vessels into the surgical area. The results suggest biocompatibility of both materials, seen by their integration into rat mandible. Moreover, the polyurethane seems to be an alternative in bone reconstruction and it is an inexhaustible source of biomaterial. PMID:19089203

  7. Surface functionalization of 3D glass-ceramic porous scaffolds for enhanced mineralization in vitro

    NASA Astrophysics Data System (ADS)

    Ferraris, Sara; Vitale-Brovarone, Chiara; Bretcanu, Oana; Cassinelli, Clara; Vernè, Enrica

    2013-04-01

    Bone reconstruction after tissue loosening due to traumatic, pathological or surgical causes is in increasing demand. 3D scaffolds are a widely studied solution for supporting new bone growth. Bioactive glass-ceramic porous materials can offer a three-dimensional structure that is able to chemically bond to bone. The ability to surface modify these devices by grafting biologically active molecules represents a challenge, with the aim of stimulating physiological bone regeneration with both inorganic and organic signals. In this research work glass ceramic scaffolds with very high mechanical properties and moderate bioactivity have been functionalized with the enzyme alkaline phosphatase (ALP). The material surface was activated in order to expose hydroxyl groups. The activated surface was further grafted with ALP both via silanization and also via direct grafting to the surface active hydroxyl groups. Enzymatic activity of grafted samples were measured by means of UV-vis spectroscopy before and after ultrasonic washing in TRIS-HCl buffer solution. In vitro inorganic bioactivity was investigated by soaking the scaffolds after the different steps of functionalization in a simulated body fluid (SBF). SEM observations allowed the monitoring of the scaffold morphology and surface chemical composition after soaking in SBF. The presence of ALP enhanced the in vitro inorganic bioactivity of the tested material.

  8. Accomplishments and challenges of surgical simulation.

    PubMed

    Satava, R M

    2001-03-01

    For nearly a decade, advanced computer technologies have created extraordinary educational tools using three-dimensional (3D) visualization and virtual reality. Pioneering efforts in surgical simulation with these tools have resulted in a first generation of simulators for surgical technical skills. Accomplishments include simulations with 3D models of anatomy for practice of surgical tasks, initial assessment of student performance in technical skills, and awareness by professional societies of potential in surgical education and certification. However, enormous challenges remain, which include improvement of technical fidelity, standardization of accurate metrics for performance evaluation, integration of simulators into a robust educational curriculum, stringent evaluation of simulators for effectiveness and value added to surgical training, determination of simulation application to certification of surgical technical skills, and a business model to implement and disseminate simulation successfully throughout the medical education community. This review looks at the historical progress of surgical simulators, their accomplishments, and the challenges that remain.

  9. Three-Year Outcome of Fixed Partial Rehabilitations Supported by Implants Inserted with Flap or Flapless Surgical Techniques.

    PubMed

    Maló, Paulo; de Araújo Nobre, Miguel; Lopes, Armando

    2016-07-01

    The aim of this prospective clinical study was to evaluate the 3-year outcome of fixed partial prostheses supported by implants with immediate provisionalization without occlusal contacts inserted in predominantly soft bone with flap and flapless protocols. Forty-one patients partially rehabilitated with 72 NobelSpeedy implants (51 maxillary; 21 mandibular) were consecutively included and treated with a flapless surgical protocol (n = 20 patients; 32 implants) and flapped surgical protocol (n = 21 patients; 40 implants). Primary outcome measure was implant survival; secondary outcome measures were marginal bone resorption (comparing the bone levels at 1 and 3 years with baseline) and the incidence of biological, mechanical, and esthetic complications. Survival was computed through life tables; descriptive statistics were applied to the remaining variables of interest. Eight patients with eight implants dropped out of the study. One implant failed in one patient (flapless group) giving an overall cumulative survival rate (CSR) of 98.6%. No failures were noted with the flapped protocol (CSR 100%), while for the implants placed with the flapless surgical technique, a 96.9% CSR was registered. The overall average marginal bone resorption at 3 years was 1.37 mm (SD = 0.94 mm), with 1.14 mm (SD = 0.49 mm) and 1.60 mm (SD = 1.22 mm) for the flap and flapless groups, respectively. Mechanical complications occurred in nine patients (n = 5 patients in the flapless group; n = 4 patients in the flap group). Implant infection was registered in three implants and three patients (flapless group), who exhibited inadequate oral hygiene levels. Partial edentulism rehabilitation through immediate provisionalization fixed prosthesis supported by dental implants inserted through flap or flapless surgical techniques in areas of predominantly soft bone was viable at 3 years of follow-up. The limitations and risks of the "free-hand" method in flapless surgery should be considered when planning implant-supported fixed prosthetic reconstructions. © 2015 by the American College of Prosthodontists.

  10. Repeat Intracranial Expansion After Skull Regrowth in Hyperostotic Disease: Technical Note.

    PubMed

    Wong, Timothy; Herschman, Yehuda; Patel, Nitesh V; Patel, Tushar; Hanft, Simon

    2017-06-01

    Camurati-Engelmann disease (CED) is a rare, autosomal-dominant genetic disorder resulting in hyperostosis of the long bones and skull. Patients often develop cranial nerve dysfunction and increased intracranial pressure secondary to stenosis of nerve foramina and hyperostosis. Surgical decompression may provide symptomatic relief in select patients; however, a small number of reports document the recurrence of symptoms due to bony regrowth. We present a patient who had been treated previously with bilateral frontal and parietal craniotomy who experienced recurrence of symptoms due to reossification of her cranial bones. This report underscores the progressive nature of CED and its influence on surgical management. Furthermore, we propose a novel surgical approach with multiple craniectomies and titanium mesh cranioplasties that could potentially offer long-term symptomatic relief. A 46-year-old female patient with CED who was treated with ventriculoperitoneal shunting, posterior fossa decompression, and multiple craniotomies 2 decades prior presented with signs and symptoms of increased intracranial pressure. Studies of the skull at presentation demonstrated rethickening of cranial bones that resulted in severely decreased intracranial volume. A radical craniectomy, requiring 4 separate bone flaps made up of bilateral frontal and parietal bones, was performed. The remaining coronal and sagittal bony struts were drilled to approximately 1 cm thick. Cranioplasties with 4 separate titanium meshes were performed to preserve the natural contour of the patient's skull. Although surgical decompression could provide some patients with CED symptomatic relief, clinicians should consider managing CED as a chronic condition. To the authors' knowledge, this is one of few case reports documenting the recurrence of symptoms in a patient with CED treated by surgical intervention. Furthermore, we propose that multiple craniectomies with titanium mesh cranioplasties confer more permanent symptomatic control, and, more importantly, lower the risk of recurrence secondary to cranial hyperostosis. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. The efficacy of mobile application use on recall of surgical risks in nasal bone fracture reduction surgery

    PubMed Central

    Kim, Choong Hyeon; Cheon, Ji Seon; Choi, Woo Young; Son, Kyung Min

    2018-01-01

    Background The number of surgical risks recalled by a patient after surgery can be used as a parameter for assessing how well the patient has understood the informed consent process. No study has investigated the usefulness of a self-developed mobile application in the traditional informed consent process in patients with a nasal bone fracture. This study aimed to investigate whether delivery of information, such as surgical risks, through a mobile application is more effective than delivery of information through only verbal means and a paper. Methods This prospective, randomized study included 60 patients with a nasal bone fracture. The experimental group (n=30) received preoperative explanation with the traditional informed consent process in addition to a mobile application, while the control group (n=30) received preoperative explanation with only the traditional informed consent process. Four weeks after surgery, the number of recalled surgical risks was compared for analysis. The following six surgical risks were explained: pain, bleeding, nasal deformity, numbness, nasal obstruction, and nasal cartilage necrosis. Results The mean number of recalled surgical risks among all patients was 1.58±0.56. The most frequently recalled surgical risk was nasal deformity in both groups. The mean number of recalled surgical risks was 1.72±0.52 in the experimental group and 1.49±0.57 in the control group. There was a significant association between mobile application use and the mean number of recalled surgical risks (p=0.047). Age, sex, and the level of education were not significantly associated with the mean number of recalled surgical risks. Conclusion This study found that a mobile application could contribute to the efficient delivery of information during the informed consent process. With further improvement, it could be used in other plastic surgeries and other surgeries, and such an application can potentially be used for explaining risks as well as delivering other types of information. PMID:29609431

  12. The efficacy of mobile application use on recall of surgical risks in nasal bone fracture reduction surgery.

    PubMed

    Kim, Choong Hyeon; Cheon, Ji Seon; Choi, Woo Young; Son, Kyung Min

    2018-03-01

    The number of surgical risks recalled by a patient after surgery can be used as a parameter for assessing how well the patient has understood the informed consent process. No study has investigated the usefulness of a self-developed mobile application in the traditional informed consent process in patients with a nasal bone fracture. This study aimed to investigate whether delivery of information, such as surgical risks, through a mobile application is more effective than delivery of information through only verbal means and a paper. This prospective, randomized study included 60 patients with a nasal bone fracture. The experimental group (n=30) received preoperative explanation with the traditional informed consent process in addition to a mobile application, while the control group (n=30) received preoperative explanation with only the traditional informed consent process. Four weeks after surgery, the number of recalled surgical risks was compared for analysis. The following six surgical risks were explained: pain, bleeding, nasal deformity, numbness, nasal obstruction, and nasal cartilage necrosis. The mean number of recalled surgical risks among all patients was 1.58±0.56. The most frequently recalled surgical risk was nasal deformity in both groups. The mean number of recalled surgical risks was 1.72±0.52 in the experimental group and 1.49±0.57 in the control group. There was a significant association between mobile application use and the mean number of recalled surgical risks ( p =0.047). Age, sex, and the level of education were not significantly associated with the mean number of recalled surgical risks. This study found that a mobile application could contribute to the efficient delivery of information during the informed consent process. With further improvement, it could be used in other plastic surgeries and other surgeries, and such an application can potentially be used for explaining risks as well as delivering other types of information.

  13. Osteochondroma of the Scapula with Accessory Nerve (XI) Compression.

    PubMed

    Beauchamp-Chalifour, Philippe; Pelet, Stéphane

    2018-01-01

    Osteochondroma is the most common benign bone tumor and is characterized as a cartilage-capped bony stalk. This lesion usually develops from the growth plate of long bones. Most osteochondromas are asymptomatic. Neurovascular compressions or cosmetic issues can occur in specific locations. Malignant transformation is extremely rare, and MRI can help evaluate these lesions. Symptomatic mass and malignancy features are the main surgical indications. Uncommonly, an osteochondroma can develop from flat bones. We present the case of a 25-year-old patient with a right scapula osteochondroma causing an accessory nerve compression. The mass was surgically removed, and the diagnosis was confirmed. The patient fully recovered at the latest 3-year follow-up visit.

  14. Design and Validation of 3D Printed Complex Bone Models with Internal Anatomic Fidelity for Surgical Training and Rehearsal.

    PubMed

    Unger, Bertram J; Kraut, Jay; Rhodes, Charlotte; Hochman, Jordan

    2014-01-01

    Physical models of complex bony structures can be used for surgical skills training. Current models focus on surface rendering but suffer from a lack of internal accuracy due to limitations in the manufacturing process. We describe a technique for generating internally accurate rapid-prototyped anatomical models with solid and hollow structures from clinical and microCT data using a 3D printer. In a face validation experiment, otolaryngology residents drilled a cadaveric bone and its corresponding printed model. The printed bone models were deemed highly realistic representations across all measured parameters and the educational value of the models was strongly appreciated.

  15. [Repair of a root perforation by using MTA: a case report].

    PubMed

    Riccitiello, Francesco; Di Caprio, Maria Patrizia; D'Amora, Marilina; Pizza, Nunzia Luisa; Vallone, Gianfranco; D'Ambrosio, Colomba; Amato, Massimo

    2013-01-01

    Root perforations are accidental events that may occur during the treatment, causing tissue inflammation and alveolar bone loss of integrity of the periodontium. In such cases, the radiological evidence is fundamental in the formulation of the diagnosis, in the choice of therapy (surgical or non-surgical) and finally for the assessment of prognosis of the dental element. In non-surgical treatment of endodontic lesions, the material used for the repair of the defect root should have biocompatibility, antibacterial activity, ability to induce healing of periodontal tissues and radiopacity. The Mineral Trioxide Aggregate (MTA) is a silicate-based cement introduced in dental clinical practice with good radiopacity, biocompatibility and bone induction. This article describes the use of MTA in endodontic repair of a perforation of the middle third root and the success of non-surgical treatment was dimonstrated radiographicaly.

  16. Combined orthognathic distraction procedure: Le Fort I maxillary osteotomy and mandibular curvilinear distraction osteogenesis. A new technique for craniofacial management.

    PubMed

    Schendel, Stephen A; Hazan-Molina, Hagai; Aizenbud, Dror

    2014-04-01

    Dentofacial deformities are traditionally treated by maxillary and mandibular osteotomies conducted separately or simultaneously. Recently, distraction osteogenesis has become an irreplaceable part of the surgical armamentarium, for its ability to induce new bone formation between the surfaces of bone segments that are gradually separated by incremental traction, along with a simultaneous expansion of the surrounding soft-tissue envelope. The aim of this article is to describe a combined surgical technique consisting of simultaneous maxillary Le Fort I advancement and mandibular surgical repositioning by means of bilateral sagittal split osteotomy with a curvilinear distractor based on a preliminary computerized presurgical prediction.

  17. The effectiveness of and satisfaction with high-fidelity simulation to teach cardiac surgical resuscitation skills to nurses.

    PubMed

    McRae, Marion E; Chan, Alice; Hulett, Renee; Lee, Ai Jin; Coleman, Bernice

    2017-06-01

    There are few reports of the effectiveness or satisfaction with simulation to learn cardiac surgical resuscitation skills. To test the effect of simulation on the self-confidence of nurses to perform cardiac surgical resuscitation simulation and nurses' satisfaction with the simulation experience. A convenience sample of sixty nurses rated their self-confidence to perform cardiac surgical resuscitation skills before and after two simulations. Simulation performance was assessed. Subjects completed the Satisfaction with Simulation Experience scale and demographics. Self-confidence scores to perform all cardiac surgical skills as measured by paired t-tests were significantly increased after the simulation (d=-0.50 to 1.78). Self-confidence and cardiac surgical work experience were not correlated with time to performance. Total satisfaction scores were high (mean 80.2, SD 1.06) indicating satisfaction with the simulation. There was no correlation of the satisfaction scores with cardiac surgical work experience (τ=-0.05, ns). Self-confidence scores to perform cardiac surgical resuscitation procedures were higher after the simulation. Nurses were highly satisfied with the simulation experience. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Changes in Mechanical Properties of Rat Bones under Simulated Effects of Microgravity and Radiation†

    NASA Astrophysics Data System (ADS)

    Walker, Azida H.; Perkins, Otis; Mehta, Rahul; Ali, Nawab; Dobretsov, Maxim; Chowdhury, Parimal

    The aim of this study was to determine the changes in elasticity and lattice structure in leg bone of rats which were: 1) under Hind-Limb Suspension (HLS) by tail for 2 weeks and 2) exposed to a total radiation of 10 Grays in 10 days. The animals were sacrificed at the end of 2 weeks and the leg bones were surgically removed, cleaned and fixed with a buffered solution. The mechanical strength of the bone (elastic modulus) was determined from measurement of bending of a bone when under an applied force. Two methodologies were used: i) a 3-point bending technique and ii) classical bending where bending is accomplished keeping one end fixed. Three point bending method used a captive actuator controlled by a programmable IDEA drive. This allowed incremental steps of 0.047 mm for which the force is measured. The data is used to calculate the stress and the strain. In the second method a mirror attached to the free end of the bone allowed a reflected laser beam spot to be tracked. This provided the displacement measurement as stress levels changed. Analysis of stress vs. strain graph together with solution of Euler-Bernoulli equation for a cantilever beam allowed determination of the elastic modulus of the leg bone for (i) control samples, (ii) HLS samples and (iii) HLS samples with radiation effects. To ascertain changes in the bone lattice structure, the bones were cross-sectioned and imaged with a 20 keV beam of electrons in a Scanning Electron Microscope (SEM). A backscattered detector and a secondary electron detector in the SEM provided the images from well-defined parts of the leg bones. Elemental compositions in combination with mechanical properties (elastic modulus and lattice structure) changes indicated weakening of the bones under space-like conditions of microgravity and radiation.

  19. MR imaging in staging of bone tumors

    PubMed Central

    Ehara, Shigeru

    2006-01-01

    For staging of bone tumors, TNM and Enneking’s systems are used with some differences. Magnetic resonance imaging is particularly useful for defining the extent of high-grade tumors, including transcortical and intertrabecular infiltration and periosteal extension. The concepts of compartment and curative surgical margins are important for bone tumor staging. PMID:17098647

  20. An Efficient and Reproducible Protocol for Distraction Osteogenesis in a Rat Model Leading to a Functional Regenerated Femur.

    PubMed

    Pithioux, Martine; Roseren, Flavy; Jalain, Christian; Launay, Franck; Charpiot, Philippe; Chabrand, Patrick; Roffino, Sandrine; Lamy, Edouard

    2017-10-23

    This protocol describes the use of a newly developed external fixator for distraction osteogenesis in a rat femoral model. Distraction osteogenesis (DO) is a surgical technique leading to bone regeneration after an osteotomy. The osteotomized extremities are moved away from each other by gradual distraction to reach the desired elongation. This procedure is widely used in humans for lower and upper limb lengthening, treatment after a bone nonunion, or the regeneration of a bone defect following surgery for bone tumor excision, as well as in maxillofacial reconstruction. Only a few studies clearly demonstrate the efficiency of their protocol in obtaining a functional regenerated bone, i.e., bone that will support physiological weight-bearing without fracture after removal of the external fixator. Moreover, protocols for DO vary and reproducibility is limited by lack of information, making comparison between studies difficult. The aim of this study was to develop a reproducible protocol comprising an appropriate external fixator design for rat limb lengthening, with a detailed surgical technique that permits physiological weight-bearing by the animal after removal of the external fixator.

  1. Surface structural damage study in cortical bone due to medical drilling.

    PubMed

    Tavera R, Cesar G; De la Torre-I, Manuel H; Flores-M, Jorge M; Hernandez M, Ma Del Socorro; Mendoza-Santoyo, Fernando; Briones-R, Manuel de J; Sanchez-P, Jorge

    2017-05-01

    A bone's fracture could be produced by an excessive, repetitive, or sudden load. A regular medical practice to heal it is to fix it in two possible ways: external immobilization, using a ferule, or an internal fixation, using a prosthetic device commonly attached to the bone by means of surgical screws. The bone's volume loss due to this drilling modifies its structure either in the presence or absence of a fracture. To observe the bone's surface behavior caused by the drilling effects, a digital holographic interferometer is used to analyze the displacement surface's variations in nonfractured post-mortem porcine femoral bones. Several nondrilled post-mortem bones are compressed and compared to a set of post-mortem bones with a different number of cortical drillings. During each compression test, a series of digital interferometric holograms were recorded using a high-speed CMOS camera. The results are presented as pseudo 3D mesh displacement maps for comparisons in the physiological range of load (30 and 50 lbs) and beyond (100, 200, and 400 lbs). The high resolution of the optical phase gives a better understanding about the bone's microstructural modifications. Finally, a relationship between compression load and bone volume loss due to the drilling was observed. The results prove that digital holographic interferometry is a viable technique to study the conditions that avoid the surgical screw from loosening in medical procedures of this kind.

  2. Real-time in situ three-dimensional integral videography and surgical navigation using augmented reality: a pilot study

    PubMed Central

    Suenaga, Hideyuki; Hoang Tran, Huy; Liao, Hongen; Masamune, Ken; Dohi, Takeyoshi; Hoshi, Kazuto; Mori, Yoshiyuki; Takato, Tsuyoshi

    2013-01-01

    To evaluate the feasibility and accuracy of a three-dimensional augmented reality system incorporating integral videography for imaging oral and maxillofacial regions, based on preoperative computed tomography data. Three-dimensional surface models of the jawbones, based on the computed tomography data, were used to create the integral videography images of a subject's maxillofacial area. The three-dimensional augmented reality system (integral videography display, computed tomography, a position tracker and a computer) was used to generate a three-dimensional overlay that was projected on the surgical site via a half-silvered mirror. Thereafter, a feasibility study was performed on a volunteer. The accuracy of this system was verified on a solid model while simulating bone resection. Positional registration was attained by identifying and tracking the patient/surgical instrument's position. Thus, integral videography images of jawbones, teeth and the surgical tool were superimposed in the correct position. Stereoscopic images viewed from various angles were accurately displayed. Change in the viewing angle did not negatively affect the surgeon's ability to simultaneously observe the three-dimensional images and the patient, without special glasses. The difference in three-dimensional position of each measuring point on the solid model and augmented reality navigation was almost negligible (<1 mm); this indicates that the system was highly accurate. This augmented reality system was highly accurate and effective for surgical navigation and for overlaying a three-dimensional computed tomography image on a patient's surgical area, enabling the surgeon to understand the positional relationship between the preoperative image and the actual surgical site, with the naked eye. PMID:23703710

  3. Incidence of bacterial contamination and predisposing factors during bone and tendon allograft procurement.

    PubMed

    Terzaghi, Clara; Longo, Alessia; Legnani, Claudio; Bernasconi, Davide Paolo; Faré, Maristella

    2015-03-01

    The aim of this study was to analyze factors contributing to bacteriological contamination of bone and tendon allograft. Between 2008 and 2011, 2,778 bone and tendon allografts obtained from 196 organ and tissue donors or tissue donors only were retrospectively analysed. Several variables were taken into account: donor type (organ and tissue donors vs. tissue donor), cause of death, time interval between death and tissue procurement, duration of the procurement procedure, type of allografts, number of team members, number of trainees members, associated surgical procedures, positivity to haemoculture, type of procurement. The overall incidence of graft contamination was 23 %. The cause of death, the procurement time, the duration of procurement, the associated surgical procedures were not associated with increased risk of contamination. Significant effect on contamination incidence was observed for the number of staff members performing the procurement. In addition, our study substantiated significantly higher contamination rate among bone allografts than from tendon grafts. According to these observations, in order to minimize the contamination rate of procured musculoskeletal allografts, we recommend appropriate donor selection, use of standard sterile techniques, immediate packaging of each allograft to reduce graft exposure. Allograft procurement should be performed by a small surgical team.

  4. The biology of distraction osteogenesis for correction of mandibular and craniomaxillofacial defects: A review

    PubMed Central

    Natu, Subodh Shankar; Ali, Iqbal; Alam, Sarwar; Giri, Kolli Yada; Agarwal, Anshita; Kulkarni, Vrishali Ajit

    2014-01-01

    Limb lengthening by distraction osteogenesis was first described in 1905. The technique did not gain wide acceptance until Gavril Ilizarov identified the physiologic and mechanical factors governing successful regeneration of bone formation. Distraction osteogenesis is a new variation of more traditional orthognathic surgical procedure for the correction of dentofacial deformities. It is most commonly used for the correction of more severe deformities and syndromes of both the maxilla and the mandible and can also be used in children at ages previously untreatable. The basic technique includes surgical fracture of deformed bone, insertion of device, 5-7 days rest, and gradual separation of bony segments by subsequent activation at the rate of 1 mm per day, followed by an 8-12 weeks consolidation phase. This allows surgeons, the lengthening and reshaping of deformed bone. The aim of this paper is to review the principle, technical considerations, applications and limitations of distraction osteogenesis. The application of osteodistraction offers novel solutions for surgical-orthodontic management of developmental anomalies of the craniofacial skeleton as bone may be molded into different shapes along with the soft tissue component gradually thereby resulting in less relapse. PMID:24688555

  5. Treatment options for diabetic foot osteomyelitis.

    PubMed

    Senneville, Eric; Robineau, Olivier

    2017-06-01

    Diabetic foot osteomyelitis therapeutical options are based on antibiotic therapy and surgical resection of the infected bone(s). Surgical and medical approaches of patients suffering from a diabetic foot osteomyelitis do not oppose but are complementary and need to be discussed as a tailored manner. Areas covered: The aim of the present article is to discuss data issued from the most recent guidelines of the Infectious Diseases Society of America and the International Working Group on the Diabetic Foot on the management of the diabetic foot infection and from a search in the current literature using the terms diabetic foot osteomyelitis and treatment/therapy/therapeutical in both PubMed and Medline, restricted to the last five years. Expert opinion: Surgical removal of the entire infected bone(s) has been considered in the past as the standard treatment but medical approach of these patients has now proven efficacy in selected situations. The current emergence of bacteria, especially among Gram negative rods, resistant to almost all the available antibiotics gradually augments the complexity of the management of these patients and is likely to decrease the place of the medical approach and to worsen the outcome of these infections in the next future.

  6. Biomechanics Analysis of Pressure Ulcer Using Damaged Interface Model between Bone and Muscle in the Human Buttock

    NASA Astrophysics Data System (ADS)

    Slamet, Samuel Susanto; Takano, Naoki; Tanabe, Yoshiyuki; Hatano, Asako; Nagasao, Tomohisa

    This paper aims at building up a computational procedure to study the bio-mechanism of pressure ulcer using the finite element method. Pressure ulcer is a disease that occurs in the human body after 2 hours of continuous external force. In the very early stage of pressure ulcer, it is found that the tissues inside the body are damaged, even though skin surface looks normal. This study assumes that tension and/or shear strain will cause damage to loose fibril tissue between the bone and muscle and that propagation of damaged area will lead to fatal stage. Analysis was performed using the finite element method by modeling the damaged fibril tissue as a cutout. By varying the loading directions and watching both tensile and shear strains, the risk of fibril tissue damage and propagation of the damaged area is discussed, which may give new insight for the careful nursing for patients, particularly after surgical treatment. It was found that the pressure ulcer could reoccur for a surgical flap treatment. The bone cut and surgical flap surgery is not perfect to prevent the bone-muscle interfacial damage.

  7. Bone Metabolism after Bariatric Surgery

    PubMed Central

    Yu, Elaine W.

    2014-01-01

    Bariatric surgery is a popular and effective treatment for severe obesity, but may have negative effects on the skeleton. This review summarizes changes in bone density and bone metabolism from animal and clinical studies of bariatric surgery, with specific attention to Roux-en-Y gastric bypass (RYGB), adjustable gastric banding (AGB), and sleeve gastrectomy (SG). Skeletal imaging artifacts from obesity and weight loss are also considered. Despite challenges in bone density imaging, the preponderance of evidence suggests that bariatric surgery procedures have negative skeletal effects that persist beyond the first year of surgery, and that these effects vary by surgical type. The long-term clinical implications and current clinical recommendations are presented. Further study is required to determine mechanisms of bone loss after bariatric surgery. Although early studies focused on calcium/vitamin D metabolism and mechanical unloading of the skeleton, it seems likely that surgically-induced changes in the hormonal and metabolic profile may be responsible for the skeletal phenotypes observed after bariatric surgery. PMID:24677277

  8. Review of ectodermal dysplasia: case report on treatment planning and surgical management of oligodontia with implant restorations.

    PubMed

    Li, Dehua; Liu, Yanpu; Ma, Wei; Song, Yingliang

    2011-10-01

    Dental implants have proven to be a reliable modality for the rehabilitation of missing teeth. However, there are limited reports on managing anodontia related to ectodermal dysplasia in the scientific literature. The severely reduced bone quantity due to the congenital absence of multiple natural teeth is the biggest challenge for the surgeon. There are a variety of bone augmentation procedures to establish adequate bone quantity, and the surgical planning should be used on an individual case basis. This is a report of a 19-year-old male patient affected by hypohidrotic ectodermal dysplasia. Oligodontia associated with severe atrophy of jaws was the chief complaint for seeking treatment. Based on clinical and radiographic examinations, 2 bone augmentation procedures were used to obtain sufficient width of alveolus for implant placement by performing an onlay bone graft in the maxilla and vertical distraction osteogenesis in the mandible. The treatment planning was discussed and informed consent was obtained.

  9. Behavioural and cognitive effects of simvastatin dose used in stimulation of bone regeneration in rats.

    PubMed

    Sousa, Dircilei Nascimento de; Santana, Washington Macedo de; Ferreira, Vania Moraes; Duarte, Wagner Rodrigues

    2014-03-01

    To analyze the effects of simvastatin (SVT) in the locomotion, anxiety and memory of rats, as a reflection of the administration of a minimum dose capable of stimulating bone regeneration in defects in the calvariae. Surgical procedures were performed in 15 female Wistar rats, 2-month old, to insert the grafting material regenerator (Bone-ceramic®) and/or SVT, followed by behavioural and cognitive assessments in the 7th, 30th and 60th days post surgery. The SVT locally applied with the goal of bone regeneration in defects created in rat calvariae does not interfere with locomotion, anxiety levels and/or memories of rats, except for the first week following surgery, when an anxiolytic effect was observed, as a result of a possible central action. Failure to provoke any response within 30 and 60 days post surgical procedures suggests that SVT may constitute a good choice in stimulating bone regeneration without affecting the long term neural functions.

  10. EARLY COMPLICATIONS IN THE ORTHOPEDIC TREATMENT OF BONE METASTASES

    PubMed Central

    Teixeira, Luiz Eduardo Moreira; Miranda, Ricardo Horta; Ghedini, Daniel Ferreira; Aguilar, Rafael Bazílio; Novais, Eduardo Nilo Vasconcelos; de Abreu e Silva, Guilherme Moreira; Araújo, Ivana Duval; de Andrade, Marco Antônio Percope

    2015-01-01

    Objective: To assess the early complications in the orthopedic treatment of metastatic bone lesions and the factors associated with these complications. Method: There were assessed, retrospectively, 64 patients that underwent surgical treatment for bone metastases, analyzing the complications that occurred in the pre-operative and early post- operative period and associating them with the tumor origin, type of procedure done, the need of blood reposition before the surgery, the need of new surgical procedures and the mortality due to the complications. Results: Early complications in the treatment were observed in 17 (26.6%) patients, of which six (35.2%) ended up dying due to these complications. Regarding the type, 15 (23.8%) cases were due to surgical complications, four (6.3%) clinical and three (4.7%) patients showed clinical and surgical complications. There was no significant difference in the frequency of complications or mortality when assessed the type of reconstruction or affected region. The tumors with a renal origin needed more blood reposition and showed a bigger frequency of complications. Conclusion: The complications occurred in 26.6%. The complications are not related to the kind of treatment performed or to the region affected. The renal origin tumors showed a higher risk of hemorrhage. PMID:27077063

  11. EARLY COMPLICATIONS IN THE ORTHOPEDIC TREATMENT OF BONE METASTASES.

    PubMed

    Teixeira, Luiz Eduardo Moreira; Miranda, Ricardo Horta; Ghedini, Daniel Ferreira; Aguilar, Rafael Bazílio; Novais, Eduardo Nilo Vasconcelos; de Abreu E Silva, Guilherme Moreira; Araújo, Ivana Duval; de Andrade, Marco Antônio Percope

    2009-01-01

    To assess the early complications in the orthopedic treatment of metastatic bone lesions and the factors associated with these complications. There were assessed, retrospectively, 64 patients that underwent surgical treatment for bone metastases, analyzing the complications that occurred in the pre-operative and early post- operative period and associating them with the tumor origin, type of procedure done, the need of blood reposition before the surgery, the need of new surgical procedures and the mortality due to the complications. Early complications in the treatment were observed in 17 (26.6%) patients, of which six (35.2%) ended up dying due to these complications. Regarding the type, 15 (23.8%) cases were due to surgical complications, four (6.3%) clinical and three (4.7%) patients showed clinical and surgical complications. There was no significant difference in the frequency of complications or mortality when assessed the type of reconstruction or affected region. The tumors with a renal origin needed more blood reposition and showed a bigger frequency of complications. The complications occurred in 26.6%. The complications are not related to the kind of treatment performed or to the region affected. The renal origin tumors showed a higher risk of hemorrhage.

  12. Emerging Perspectives in Scaffold for Tissue Engineering in Oral Surgery.

    PubMed

    Ceccarelli, Gabriele; Presta, Rossella; Benedetti, Laura; Cusella De Angelis, Maria Gabriella; Lupi, Saturnino Marco; Rodriguez Y Baena, Ruggero

    2017-01-01

    Bone regeneration is currently one of the most important and challenging tissue engineering approaches in regenerative medicine. Bone regeneration is a promising approach in dentistry and is considered an ideal clinical strategy in treating diseases, injuries, and defects of the maxillofacial region. Advances in tissue engineering have resulted in the development of innovative scaffold designs, complemented by the progress made in cell-based therapies. In vitro bone regeneration can be achieved by the combination of stem cells, scaffolds, and bioactive factors. The biomimetic approach to create an ideal bone substitute provides strategies for developing combined scaffolds composed of adult stem cells with mesenchymal phenotype and different organic biomaterials (such as collagen and hyaluronic acid derivatives) or inorganic biomaterials such as manufactured polymers (polyglycolic acid (PGA), polylactic acid (PLA), and polycaprolactone). This review focuses on different biomaterials currently used in dentistry as scaffolds for bone regeneration in treating bone defects or in surgical techniques, such as sinus lift, horizontal and vertical bone grafts, or socket preservation. Our review would be of particular interest to medical and surgical researchers at the interface of cell biology, materials science, and tissue engineering, as well as industry-related manufacturers and researchers in healthcare, prosthetics, and 3D printing, too.

  13. Stem cell applications and tissue engineering approaches in surgical practice.

    PubMed

    Khan, Wasim S; Malik, Atif A; Hardingham, Timothy E

    2009-04-01

    There has been an increasing interest in stem cell applications and tissue engineering approaches in surgical practice to deal with damaged or lost tissue. Although there have been developments in almost all surgical disciplines, the greatest advances are being made in orthopaedics, especially in bone repair. Significant hurdles however remain to be overcome before tissue engineering becomes more routinely used in surgical practice.

  14. Effects of testosterone replacement therapy on bone metabolism in male post-surgical hypogonadotropic hypogonadism: focus on the role of androgen receptor CAG polymorphism.

    PubMed

    Tirabassi, G; delli Muti, N; Gioia, A; Biagioli, A; Lenzi, A; Balercia, G

    2014-04-01

    The relationship between androgen receptor (AR) CAG polymorphism and bone metabolism is highly controversial. We, therefore, aimed to evaluate the independent role of AR CAG repeat polymorphism on bone metabolism improvement induced by testosterone replacement therapy (TRT) in male post-surgical hypogonadotropic hypogonadism, a condition frequently associated with hypopituitarism and in which the effects of TRT have to be distinguished from those resulting from concomitant administration of pituitary function replacing hormones. 12 men affected by post-surgical hypogonadotropic hypogonadism [mean duration of hypogonadism 8.3 ± 2.05 (SD) months] were retrospectively assessed before and after TRT (from 74 to 84 weeks after the beginning of therapy). The following measures were studied: parameters of bone metabolism [serum markers and bone mineral density (BMD)], pituitary dependent hormones and genetic analysis (AR CAG repeat number). Total testosterone, estradiol, free T4 (FT4) and insulin-like growth factor-1 (IGF-1) increased between the two phases, while follicle stimulating hormone (FSH) decreased. While serum markers did not vary significantly between the two phases, BMD improved slightly but significantly in all the studied sites. The number of CAG triplets correlated negatively and significantly with all the variations (Δ-) of BMDs. Conversely, Δ-testosterone correlated positively and significantly with all studied Δ-BMDs, while Δ-FSH, Δ-estradiol, Δ-FT4, and Δ-IGF-1 did not correlate significantly with any of the Δ-BMDs. Multiple linear regression analysis, after correction for Δ-testosterone, showed that CAG repeat length was negatively and significantly associated with ∆-BMD of all measured sites. Our data suggest that, in post-surgical male hypogonadotropic hypogonadism, shorter AR CAG tract is independently associated with greater TRT-induced improvement of BMD.

  15. Temporal bone borehole accuracy for cochlear implantation influenced by drilling strategy: an in vitro study.

    PubMed

    Kobler, Jan-Philipp; Schoppe, Michael; Lexow, G Jakob; Rau, Thomas S; Majdani, Omid; Kahrs, Lüder A; Ortmaier, Tobias

    2014-11-01

    Minimally invasive cochlear implantation is a surgical technique which requires drilling a canal from the mastoid surface toward the basal turn of the cochlea. The choice of an appropriate drilling strategy is hypothesized to have significant influence on the achievable targeting accuracy. Therefore, a method is presented to analyze the contribution of the drilling process and drilling tool to the targeting error isolated from other error sources. The experimental setup to evaluate the borehole accuracy comprises a drill handpiece attached to a linear slide as well as a highly accurate coordinate measuring machine (CMM). Based on the specific requirements of the minimally invasive cochlear access, three drilling strategies, mainly characterized by different drill tools, are derived. The strategies are evaluated by drilling into synthetic temporal bone substitutes containing air-filled cavities to simulate mastoid cells. Deviations from the desired drill trajectories are determined based on measurements using the CMM. Using the experimental setup, a total of 144 holes were drilled for accuracy evaluation. Errors resulting from the drilling process depend on the specific geometry of the tool as well as the angle at which the drill contacts the bone surface. Furthermore, there is a risk of the drill bit deflecting due to synthetic mastoid cells. A single-flute gun drill combined with a pilot drill of the same diameter provided the best results for simulated minimally invasive cochlear implantation, based on an experimental method that may be used for testing further drilling process improvements.

  16. Complex craniofacial advancement in paediatric patients: Piezoelectric and traditional technique evaluation.

    PubMed

    Spinelli, Giuseppe; Mannelli, Giuditta; Zhang, Yi Xin; Lazzeri, Davide; Spacca, Barbara; Genitori, Lorenzo; Raffaini, Mirco; Agostini, Tommaso

    2015-10-01

    The piezoelectric device allows bone cutting without damaging the surrounding soft tissues. The purpose of this study was to assess the role of this surgical instrument in paediatric craniofacial surgery in terms of safety and surgical outcomes. Thirteen consecutive paediatric patients underwent craniofacial Le Fort osteotomies type III and IV. The saw was used on the right side in seven patients and on the left side in six patients; the piezoelectric instrument was used on the right side in six patients and on the left side in seven patients. Intraoperative blood loss, surgical procedure length, incision precision, postoperative haematoma and swelling, and nerve impairment were evaluated to compare the outcomes of both procedures. A longer surgical procedure was observed in 28% of the patients when using the piezoelectric device (p = 0.032), with an intraoperative blood loss reduction of 18% (p = 0.156). Greater precision in bone cutting was reported, together with a reduction in the requirement to protect and incise adjacent soft tissues during piezoelectric osteotomies. There was a lower incidence of postoperative haematoma and swelling following piezo-osteotomy, and a significant reduction in postoperative nerve impairment (p = 0.002). The ultrasonic surgical device guaranteed a clean bone cut, preserving the integrity of the adjacent soft tissues beneath the bone. Although the time required for a piezoelectric osteotomy was longer, the total operation time remained approximately the same. In conclusion, the device's lack of power appears to be a minor problem compared with the advantages, and an ultrasonic device could be considered a valuable instrument for paediatric craniofacial advancement. Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Treatment of Spinal Tuberculosis by Debridement, Interbody Fusion and Internal Fixation via Posterior Approach Only.

    PubMed

    Tang, Ming-xing; Zhang, Hong-qi; Wang, Yu-xiang; Guo, Chao-feng; Liu, Jin-yang

    2016-02-01

    Surgical treatment for spinal tuberculosis includes focal tuberculosis debridement, segmental stability reconstruction, neural decompression and kyphotic deformity correction. For the lesions mainly involved anterior and middle column of the spine, anterior operation of debridement and fusion with internal fixation has been becoming the most frequently used surgical technique for the spinal tuberculosis. However, high risk of structural damage might relate with anterior surgery, such as damage in lungs, heart, kidney, ureter and bowel, and the deformity correction is also limited. Due to the organs are in the front of spine, there are less complications in posterior approach. Spinal pedicle screw passes through the spinal three-column structure, which provides more powerful orthopedic forces compared with the vertebral body screw, and the kyphotic deformity correction effect is better in posterior approach. In this paper, we report a 68-year-old male patient with thoracic tuberculosis who underwent surgical treatment by debridement, interbody fusion and internal fixation via posterior approach only. The patient was placed in prone position under general anesthesia. Posterior midline incision was performed, and the posterior spinal construction was exposed. Then place pedicle screw, and fix one side rod temporarily. Make the side of more bone destruction and larger abscess as lesion debridement side. Resect the unilateral facet joint, and retain contralateral structure integrity. Protect the spinal cord, nerve root. Clear sequestrum, necrotic tissue, abscess of paravertebral and intervertebral space. Specially designed titanium mesh cages or bone blocks were implanted into interbody. Fix both side rods and compress both sides to make the mesh cages and bone blocks tight. Reconstruct posterior column structure with allogeneic bone and autologous bone. Using this technique, the procedures of debridement, spinal cord decompression, deformity correction, bone grafting, and internal fixation can be completed with only one incision and surgical position, and the deformity correction efficiency is higher than anterior surgery. © 2016 Chinese Orthopaedic Association and John Wiley & Sons Australia, Ltd.

  18. Radiographic bone fill following debridement of a periodontal abscess. A case report.

    PubMed

    Khocht, A; Faldu, M G

    1998-01-01

    A periodontal abscess often develops in association with deepened periodontal pockets. Traditional management is by establishing drainage and prescribing antibiotics. This is usually followed by surgical pocket reduction. This case report discusses the remarkable healing of a periodontal abscess by establishing drainage alone without resorting to surgical pocket reduction. A 42-year-old white male presented with swollen gingivae associated with the mesiolingual of tooth #23. Increased probing depth and suppuration were evident. Radiographic bone loss on mesial #23 was present. A diagnosis of periodontal abscess was established. The abscess was drained through the orifice of the pocket. The patient failed to return for follow-up as instructed. A year later, the patient came back. Clinical evaluation showed healthy gingival tissues with probing depth of 3 mm on the mesiolingual of tooth #23. Radiographic evaluation showed bone fill of the osseous defect on the mesial of #23. The results of this case suggest that sufficient time should be allowed for healing prior to surgical pocket reduction.

  19. Measuring temperature rise during orthopaedic surgical procedures.

    PubMed

    Manoogian, Sarah; Lee, Adam K; Widmaier, James C

    2016-09-01

    A reliable means for measuring temperatures generated during surgical procedures is needed to recommend best practices for inserting fixation devices and minimizing the risk of osteonecrosis. Twenty four screw tests for three surgical procedures were conducted using the four thermocouples in the bone and one thermocouple in the screw. The maximum temperature rise recorded from the thermocouple in the screw (92.7±8.9°C, 158.7±20.9°C, 204.4±35.2°C) was consistently higher than the average temperature rise recorded in the bone (31.8±9.3°C, 44.9±12.4°C, 77.3±12.7°C). The same overall trend between the temperatures that resulted from three screw insertion procedures was recorded with significant statistical analyses using either the thermocouple in the screw or the average of several in-bone thermocouples. Placing a single thermocouple in the bone was determined to have limitations in accurately comparing temperatures from different external fixation screw insertion procedures. Using the preferred measurement techniques, a standard screw with a predrilled hole was found to have the lowest maximum temperatures for the shortest duration compared to the other two insertion procedures. Future studies evaluating bone temperature increase need to use reliable temperature measurements for recommending best practices to surgeons. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  20. The negative correlation between thyrotropin receptor-stimulating antibodies and bone mineral density in postmenopausal patients with Graves' disease.

    PubMed

    Amashukeli, Medea; Korinteli, Maka; Zerekidze, Tamar; Jikurauli, Nino; Shanava, Shorena; Tsagareli, Marina; Giorgadze, Elen

    2013-06-01

    Graves' disease is an autoimmune disorder with various clinical manifestations. Thyrotropin receptor antibodies (TRAbs), the circulating autoantibodies specific to Graves' disease, are the cause for hyperthyroidism, the most prevalent abnormality. Hyperthyroidism leads to increased bone turnover and a negative bone balance. The aims of the present study were to determine the relationship between TRAbs and bone mineral density (BMD), to assess the extent of BMD change in patients with Graves' disease, and to determine the impact of conservative and surgical therapy on BMD. Fifty female postmenopausal patients with Graves' disease were chosen for this study. Twenty women had a recent diagnosis of Graves' disease, 30 women presented with a compensated disease state after either conservative or surgical treatment, and 30 healthy postmenopausal women served as controls. Thyroid parameters were measured, and BMD values were obtained by dual energy x-ray absorptiometry scan.Femoral neck and lumbar spine BMD and T-scores were significantly lower in newly diagnosed patients compared with the control group, but a difference was not observed between the treated and control groups. Statistical analysis revealed a strong and significant negative correlation between femoral neck and lumbar spine BMD and TRAb values.Both surgical and conservative therapies are effective for restoring BMD in postmenopausal patients with Graves' disease, and the increased level of TRAb can be a useful marker of bone density impairment.

  1. Comparative evaluation of bovine derived hydroxyapatite and synthetic hydroxyapatite graft in bone regeneration of human maxillary cystic defects: a clinico-radiological study.

    PubMed

    Kattimani, Vivekanand S; Chakravarthi, Srinivas P; Neelima Devi, K Naga; Sridhar, Meka S; Prasad, L Krishna

    2014-01-01

    Bone grafts are frequently used in the treatment of bone defects. Bone harvesting can cause postoperative complications and sometimes does not provide a sufficient quantity of bone. Therefore, synthetic biomaterials have been investigated as an alternative to autogenous bone grafts. The aim of this study was to evaluate and compare bovine derived hydroxyapatite (BHA) and synthetic hydroxyapatite (SHA) graft material as bone graft substitute in maxillary cystic bony defects. Patients were analyzed by computerized densitometric study and digital radiography. In this study, 12 patients in each group were included randomly after clinical and radiological evaluation. The integration of hydroxyapatite was assessed with mean bone density, surgical site margin, and radiological bone formation characteristics, of the successful graft cases using computer densitometry and radio-visiograph. Statistical analysis was carried out using Mann-Whitney U-test, Wilcoxon matched pairs test and paired t-test. By the end of 24 th week, the grafted defects radiologically and statistically showed similar volumes of bone formation. However, the significant changes observed in the formation of bone and merging of material and surgical site margin at 1 st week to 1 st month. The results were significant and correlating with all the parameters showing the necessity of the grafting for early bone formation. However, the bone formation pattern is different in both BHA and SHA group at 3 rd month interval with significant P value. Both BHA and SHA graft materials are biocompatible for filling bone defects, showing less resorption and enhanced bone formation with similar efficacy. Our study showed maximum bone healing within 12 weeks of grafting of defects. The BHA is economical; however, price difference between the two is very nominal.

  2. Extracorporeal human bone-like tissue generation

    PubMed Central

    Rosenberg, N.; Rosenberg, O.

    2012-01-01

    Objectives The need for bone tissue supplementation exists in a wide range of clinical conditions involving surgical reconstruction in limbs, the spine and skull. The bone supplementation materials currently used include autografts, allografts and inorganic matrix components; but these pose potentially serious side-effects. In particular the availability of the autografts is usually limited and their harvesting causes surgical morbidity. Therefore for the purpose of supplementation of autologous bone graft, we have developed a method for autologous extracorporeal bone generation. Methods Human osteoblast-like cells were seeded on porous granules of tricalcium phosphate and incubated in osteogenic media while exposed to mechanical stimulation by vibration in the infrasonic range of frequencies. The generated tissue was examined microscopically following haematoxylin eosin, trichrome and immunohistochemical staining. Results Following 14 days of incubation the generated tissue showed histological characteristics of bone-like material due to the characteristic eosinophilic staining, a positive staining for collagen trichrome and a positive specific staining for osteocalcin and collagen 1. Macroscopically, this tissue appeared in aggregates of between 0.5 cm and 2 cm. Conclusions We present evidence that the interaction of the cellular, inorganic and mechanical components in vitro can rapidly generate three-dimensional bone-like tissue that might be used as an autologous bone graft. PMID:23610651

  3. Alternative Distraction Osteogenesis Technique After Implant Placement for Alveolar Ridge Augmentation of the Maxilla.

    PubMed

    Nogueira, Renato Luiz Maia; Osterne, Rafael Lima Verde; Abreu, Ricardo Teixeira; Araújo, Phelype Maia

    2017-07-01

    An alternative technique to reconstruct atrophic alveolar vertical bone after implant placement is presented. The technique consists of distraction osteogenesis or direct surgical repositioning of an implant-and-bone block segment after segmental osteotomies that can be used in esthetic or unesthetic cases. Initially, casts indicating the implant position are obtained and the future ideal prosthetic position is determined to guide the model surgery. After the model surgery, a new provisional prosthesis is fabricated, and an occlusal splint, which is used as a surgical guide and a device for distraction osteogenesis, is custom fabricated. Then, the surgery is performed. For mobilization of the implant-and-bone block segment, 2 vertical osteotomies are performed and then joined by a horizontal osteotomy. The implant-and-bone block segment is moved to the planned position. If a small movement is planned, then the implant-and-bone segment is stabilized; for larger movements, the implant-and-bone segment can be gradually moved to the final position by distraction osteogenesis. This technique has good predictability of the final position of the implant-and-bone segment and relatively fast esthetic rehabilitation. It can be considered for dental implants in regions of vertical bone atrophy. Copyright © 2017 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  4. Repairing Fractured Bones by Use of Bioabsorbable Composites

    NASA Technical Reports Server (NTRS)

    Farley, Gary L.

    2006-01-01

    A proposed method of surgical repair of fractured bones would incorporate recent and future advances in the art of composite materials. The composite materials used in this method would be biocompatible and at least partly bioabsorbable: that is, during the healing process following surgery, they would be wholly or at least partly absorbed into the bones and other tissues in which they were implanted. Relative to the traditional method, the proposed method would involve less surgery, pose less of a risk of infection, provide for better transfer of loads across fracture sites, and thereby promote better healing while reducing the need for immobilization by casts and other external devices. One requirement that both the traditional and proposed methods must satisfy is to fix the multiple segments of a broken bone in the correct relative positions. Mechanical fixing techniques used in the traditional method include the use of plates spanning the fracture site and secured to the bone by screws, serving of wire along the bone across the fracture site, insertion of metallic intramedullary rods through the hollow portion of the fractured bone, and/or inserting transverse rods through the bone, muscle, and skin to stabilize the fractured members. After the bone heals, a second surgical operation is needed to remove the mechanical fixture(s). In the proposed method, there would be no need for a second surgical operation. The proposed method is based partly on the observation that in the fabrication of a structural member, it is generally more efficient and reliable to use multiple small fasteners to transfer load across a joint than to use a single or smaller number of larger fasteners, provided that the stress fields of neighboring small fasteners do not overlap or interact. Also, multiple smaller fasteners are more reliable than are larger and fewer fasteners. However, there is a trade-off between structural efficiency and the cost of insertion time and materials. The proposed method is further based partly on the conjecture that through-the-thickness reinforcements could be excellent for fixing bone segments for surgical repair. The through-the-thickness reinforcements would superficially resemble nails in both form and function. Denoted small-diameter rods (SDRs) to distinguish them from other narrow rods, these reinforcements would be shot or otherwise inserted through adjacent segments of fractured bone to fix them in their correct relative positions (see figure). Shot insertion would be effected by use an applicator that would amount to a miniaturized and highly refined version of the pneumatic guns often used in carpentry to drive nails and brads. The applicator, envisioned to be about the size of a ball-point-pen, would be driven by pressurized carbon dioxide. To further promote stabilization of the segments, layers of bone glue could be applied to the fracture surfaces prior to insertion of the SDRs. The bone glue could be therapeutically loaded with chemicals to promote growth of bone and fight infection

  5. Adaptive scapula bone remodeling computational simulation: Relevance to regenerative medicine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Gulshan B., E-mail: gbsharma@ucalgary.ca; University of Pittsburgh, Swanson School of Engineering, Department of Bioengineering, Pittsburgh, Pennsylvania 15213; University of Calgary, Schulich School of Engineering, Department of Mechanical and Manufacturing Engineering, Calgary, Alberta T2N 1N4

    Shoulder arthroplasty success has been attributed to many factors including, bone quality, soft tissue balancing, surgeon experience, and implant design. Improved long-term success is primarily limited by glenoid implant loosening. Prosthesis design examines materials and shape and determines whether the design should withstand a lifetime of use. Finite element (FE) analyses have been extensively used to study stresses and strains produced in implants and bone. However, these static analyses only measure a moment in time and not the adaptive response to the altered environment produced by the therapeutic intervention. Computational analyses that integrate remodeling rules predict how bone will respondmore » over time. Recent work has shown that subject-specific two- and three dimensional adaptive bone remodeling models are feasible and valid. Feasibility and validation were achieved computationally, simulating bone remodeling using an intact human scapula, initially resetting the scapular bone material properties to be uniform, numerically simulating sequential loading, and comparing the bone remodeling simulation results to the actual scapula’s material properties. Three-dimensional scapula FE bone model was created using volumetric computed tomography images. Muscle and joint load and boundary conditions were applied based on values reported in the literature. Internal bone remodeling was based on element strain-energy density. Initially, all bone elements were assigned a homogeneous density. All loads were applied for 10 iterations. After every iteration, each bone element’s remodeling stimulus was compared to its corresponding reference stimulus and its material properties modified. The simulation achieved convergence. At the end of the simulation the predicted and actual specimen bone apparent density were plotted and compared. Location of high and low predicted bone density was comparable to the actual specimen. High predicted bone density was greater than actual specimen. Low predicted bone density was lower than actual specimen. Differences were probably due to applied muscle and joint reaction loads, boundary conditions, and values of constants used. Work is underway to study this. Nonetheless, the results demonstrate three dimensional bone remodeling simulation validity and potential. Such adaptive predictions take physiological bone remodeling simulations one step closer to reality. Computational analyses are needed that integrate biological remodeling rules and predict how bone will respond over time. We expect the combination of computational static stress analyses together with adaptive bone remodeling simulations to become effective tools for regenerative medicine research.« less

  6. Adaptive scapula bone remodeling computational simulation: Relevance to regenerative medicine

    NASA Astrophysics Data System (ADS)

    Sharma, Gulshan B.; Robertson, Douglas D.

    2013-07-01

    Shoulder arthroplasty success has been attributed to many factors including, bone quality, soft tissue balancing, surgeon experience, and implant design. Improved long-term success is primarily limited by glenoid implant loosening. Prosthesis design examines materials and shape and determines whether the design should withstand a lifetime of use. Finite element (FE) analyses have been extensively used to study stresses and strains produced in implants and bone. However, these static analyses only measure a moment in time and not the adaptive response to the altered environment produced by the therapeutic intervention. Computational analyses that integrate remodeling rules predict how bone will respond over time. Recent work has shown that subject-specific two- and three dimensional adaptive bone remodeling models are feasible and valid. Feasibility and validation were achieved computationally, simulating bone remodeling using an intact human scapula, initially resetting the scapular bone material properties to be uniform, numerically simulating sequential loading, and comparing the bone remodeling simulation results to the actual scapula's material properties. Three-dimensional scapula FE bone model was created using volumetric computed tomography images. Muscle and joint load and boundary conditions were applied based on values reported in the literature. Internal bone remodeling was based on element strain-energy density. Initially, all bone elements were assigned a homogeneous density. All loads were applied for 10 iterations. After every iteration, each bone element's remodeling stimulus was compared to its corresponding reference stimulus and its material properties modified. The simulation achieved convergence. At the end of the simulation the predicted and actual specimen bone apparent density were plotted and compared. Location of high and low predicted bone density was comparable to the actual specimen. High predicted bone density was greater than actual specimen. Low predicted bone density was lower than actual specimen. Differences were probably due to applied muscle and joint reaction loads, boundary conditions, and values of constants used. Work is underway to study this. Nonetheless, the results demonstrate three dimensional bone remodeling simulation validity and potential. Such adaptive predictions take physiological bone remodeling simulations one step closer to reality. Computational analyses are needed that integrate biological remodeling rules and predict how bone will respond over time. We expect the combination of computational static stress analyses together with adaptive bone remodeling simulations to become effective tools for regenerative medicine research.

  7. Use of minimally invasive spine surgical instruments for the treatment of bone tumors.

    PubMed

    Reeves, Russell A; DeWolf, Matthew C; Shaughnessy, Peter J; Ames, James B; Henderson, Eric R

    2017-11-01

    Orthopedic oncologists often encounter patients with minor bony lesions that are difficult to access surgically and therefore require large exposures out of proportion to the severity of disease that confer significant patient morbidity. Minimally invasive surgical techniques offer the advantage of smaller incisions, shorter operative times, decreased tissue damage, and decreased costs. A variety of surgical procedures have emerged using minimally invasive technologies, particularly in the field of spine surgery. Areas covered: In this article, we describe the Minimal Exposure Tubular Retractor (METRx TM ) System which is a minimally invasive surgical device that utilizes a series of dilators to permit access to a surgical site of interest. This system was developed for use in treatment of disc herniation, spinal stenosis, posterior lumbar interbody fusion, transforaminal lumbar interbody fusion and spinal cord stimulation implantation. We also describe novel uses of this system for minimally invasive biopsy and treatment of benign and metastatic bone lesions at our institution. Expert commentary: Minimally invasive surgical techniques will continue to expand into the field of orthopedic oncology. With a greater number of studies proving the safety and effectiveness of this technique, the demand for minimally invasive treatments will grow.

  8. Bone Sarcoma Pathology: Diagnostic Approach for Optimal Therapy.

    PubMed

    Rosenberg, Andrew E

    2017-01-01

    The pathologic interpretation of malignant bone tumors is one of the more challenging areas in surgical pathology. This is based on the reality that primary bone sarcomas are uncommon, demonstrate significant morphologic heterogeneity, and have a broad spectrum of biology. Accordingly, it is difficult for pathologists to acquire the necessary experience to confidently and accurately diagnose bone sarcomas. The task is further complicated by the fact that it requires the integration of clinical and radiologic information into the diagnostic process. Lastly, molecular aberrations in sarcomas are being newly discovered and their identification is often critical to make specific diagnoses. The pathologist's role in guiding optimal treatment in biopsy specimens is to make an accurate diagnosis and provide the grade and molecular aberrations when appropriate. The pathology report of resected tumors must confirm this information and assess the surgical resection margins and the percentage of necrosis if the sarcoma has been treated with neoadjuvant systemic therapy.

  9. Petrous apex cholesterol granuloma: maintenance of drainage pathway, the histopathology of surgical management and histopathologic evidence for the exposed marrow theory.

    PubMed

    Hoa, Michael; House, John W; Linthicum, Fred H

    2012-08-01

    (1) To assess the maintenance of drainage pathway patency in patients who undergo surgical management of cholesterol granulomas, (2) to review the histopathologic and radiologic changes associated with surgical drainage of petrous apex (PA) cholesterol granulomas, and (3) to provide histopathologic evidence regarding the exposed marrow theory of PA cholesterol granulomas. Retrospective case review and histopathologic analysis. Tertiary referral center. Records of 17 patients with surgically managed PA cholesterol granulomas were reviewed. Histopathologic analysis was performed on temporal bones of 11 patients with PA cholesterol granulomas from the Temporal Bone repository at the House Research Institute. Surgical drainage of PA cholesterol granulomas; follow-up radiologic imaging (computed tomography or magnetic resonance imaging), when available. Primary outcome is demonstrated maintenance of a PA outflow drainage pathway after the surgical drainage procedure as assessed by radiologic imaging, available histopathology, and/or recurrence of symptoms indicating failure of maintenance. Other measures include need for revision surgery and histopathology findings. A majority (65%) of patients exhibited maintenance of their PA drainage pathway. Histopathologic evidence suggests that the PA drainage pathway can be maintained for many years after surgical drainage. Recurrence of symptoms was related to obstruction of the drainage pathway by fibrous tissue and/or granulomatous tissue. Placement of a stent improved the patient's chance of remaining symptom-free, with recurrence of symptoms and revision surgery required in only 2 stent cases (18%) as compared with 83% of those with no stent (p ≤ 0.035). Histopathologic evidence for the exposed marrow theory of PA cholesterol granulomas was found. The majority of patients who undergo surgical drainage of PA cholesterol granulomas remain symptom-free after surgical drainage. Histopathologic analysis of temporal bone specimens provides evidence supporting the exposed marrow theory of PA cholesterol granuloma formation. Loss of patency of the PA drainage pathway may be an important predictor for symptomatic recurrence of PA cholesterol granulomas. Placement of a stent may decrease the likelihood of symptomatic recurrence.

  10. 3D Printed Surgical Instruments Evaluated by a Simulated Crew of a Mars Mission.

    PubMed

    Wong, Julielynn Y; Pfahnl, Andreas C

    2016-09-01

    The first space-based fused deposition modeling (FDM) 3D printer became operational in 2014. This study evaluated whether Mars simulation crewmembers of the Hawai'i Space Exploration Analog and Simulation (HI-SEAS) II mission with no prior surgical experience could utilize acrylonitrile butadiene styrene (ABS) thermoplastic surgical instruments FDM 3D printed on Earth to complete simulated surgical tasks. This study sought to examine the feasibility of using 3D printed surgical tools when the primary crew medical officer is incapacitated and the back-up crew medical officer must conduct a surgical procedure during a simulated extended space mission. During a 4 mo duration ground-based analog mission, five simulation crewmembers with no prior surgical experience completed 16 timed sets of simulated prepping, draping, incising, and suturing tasks to evaluate the relative speed of using four ABS thermoplastic instruments printed on Earth compared to conventional instruments. All four simulated surgical tasks were successfully performed using 3D printed instruments by Mars simulation crewmembers with no prior surgical experience. There was no substantial difference in time to completion of simulated tasks with control vs. 3D printed sponge stick, towel clamp, scalpel handle, and toothed forceps. These limited findings support further investigation into the creation of an onboard digital catalog of validated 3D printable surgical instrument design files to support autonomous, crew-administered healthcare on Mars missions. Future work could include addressing sterility, biocompatibility, and having astronaut crew medical officers test a wider range of surgical instruments printed in microgravity during actual surgical procedures. Wong JY, Pfahnl AC. 3D printed surgical instruments evaluated by a simulated crew of a Mars mission. Aerosp Med Hum Perform. 2016; 87(9):806-810.

  11. Mechanisms of Guided Bone Regeneration: A Review

    PubMed Central

    Liu, Jie; Kerns, David G

    2014-01-01

    Post-extraction crestal bone resorption is common and unavoidable which can lead to significant ridge dimensional changes. To regenerate enough bone for successful implant placement, Guided Bone Regeneration (GBR) is often required. GBR is a surgical procedure that uses barrier membranes with or without particulate bone grafts or/and bone substitutes. There are two approaches of GBR in implant therapy: GBR at implant placement (simultaneous approach) and GBR before implant placement to increase the alveolar ridge or improve ridge morphology (staged approach). Angiogenesis and ample blood supply play a critical role in promoting bone regeneration. PMID:24894890

  12. [Applied anatomy of facial recess and posterior tympanum related to cochlear implantation].

    PubMed

    Zou, Tuanming; Xie, Nanping; Guo, Menghe; Shu, Fan; Zhang, Hongzheng

    2012-05-01

    To investigate the related parameters of temporal bone structure in the surgery of cochlear implantation through facial recess approach so as to offer a theoretical reference for the avoidance of facial nerve injury and the accurate localization. In a surgical simulation experiment, twenty human temporal bones were studied. The correlation parameters were measured under surgical microscope. Distance between suprameatal spine and short process of incus was (12.44 +/- 0.51) mm. Width from crotch of chorda tympani nerve to stylomastoid foramen was (2.67 +/- 0.51) mm. Distance between short process of incus and crotch of chorda tympani nerve was (15.22 +/- 0.83) mm. The location of maximal width of the facial recess into short process of incus, crotch of chorda tympani nerve were (6.28 +/- 0.41) mm, (9.81 +/- 0.71) mm, respectively. The maximal width of the facial recess was (2.73 +/- 0.20) mm. The value at level of stapes and round window were (2.48 +/- 0.20 mm) and (2.24 +/- 0.18) mm, respectively. Distance between pyramidalis eminence and anterior round window was (2.22 +/- 0.21) mm. Width from stapes to underneath round window was (2.16 +/- 0.14) mm. These parameters provide a reference value to determine the position of cochlear inserting the electrode array into the scale tympani and opening facial recess firstly to avoid potential damage to facial nerve in surgery.

  13. Bacterial contamination levels of autogenous bone particles collected by 3 different techniques for harvesting intraoral bone grafts.

    PubMed

    Manzano-Moreno, Francisco J; Herrera-Briones, Francisco J; Linares-Recatala, Macarena; Ocaña-Peinado, Francisco M; Reyes-Botella, Candela; Vallecillo-Capilla, Manuel F

    2015-03-01

    The aim of this study was to compare levels of bacterial contamination of autogenous bone collected when using low-speed drilling, a back-action chisel, and a bone filter. Bone tissue samples were taken from 31 patients who underwent surgical extraction of their third lower molars. Before surgical removal of the molar, bone particles were collected by a low-speed drill or a back-action chisel. Then, a stringent aspiration protocol was applied during the ostectomy to collect particulate bone by a bone filter. Processing of samples commenced immediately by incubation in an anaerobic or a CO2-rich atmosphere. The number of colony-forming units (CFUs) was determined at 48 hours of culture. No significant difference in the number of CFUs per milliliter was observed between the low-speed drilling group and the back-action chisel group in the anaerobic or CO2-rich condition (P = .34). However, significantly more micro-organisms were found in the bone filter group than in the low-speed drilling group or the back-action chisel group in the anaerobic and CO2-rich conditions (P < .001). Particulate bone harvested with low-speed drilling or a back-action chisel is safer for use as an autograft than are bone particles collected with a bone filter. These results suggest that bone obtained from low-speed drilling is safe and straightforward to harvest and could be the method of choice for collecting particulate bone. Further research is needed to lower the bacterial contamination levels of autogenous bone particles used as graft material. Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  14. Mid- and long-term clinical results of surgical therapy in unicameral bone cysts

    PubMed Central

    2011-01-01

    Background Unicameral (or simple) bone cysts (UBC) are benign tumours most often located in long bones of children and adolescents. Pathological fractures are common, and due to high recurrence rates, these lesions remain a challenge to treat. Numerous surgical procedures have been proposed, but there is no general consensus of the ideal treatment. The aim of this investigation therefore was to study the long-term outcome after surgical treatment in UBC. Methods A retrospective analysis of 46 patients surgically treated for UBC was performed for short and mid-term outcome. Clinical and radiological outcome parameters were studied according to a modified Neer classification system. Long-term clinical information was retrieved via a questionnaire at a minimum follow-up of 10 years after surgery. Results Forty-six patients (17 female, 29 male) with a mean age of 10.0 ± 4.8 years and with histopathologically confirmed diagnosis of UBC were included. Pathological fractures were observed in 21 cases (46%). All patients underwent surgery for UBC (35 patients underwent curettage and bone grafting as a primary therapy, 4 curettage alone, 3 received corticoid instillation and 4 decompression by cannulated screws). Overall recurrence rate after the first surgical treatment was 39% (18/46), second (17.4% of all patients) and third recurrence (4.3%) were frequently observed and were addressed by revision surgery. Recurrence was significantly higher in young and in male patients as well as in active cysts. After a mean of 52 months, 40 out of 46 cysts were considered healed. Prognosis was significantly better when recurrence was observed later than 30 months after therapy. After a mean follow-up of 15.5 ± 6.2 years, 40 patients acknowledged clinically excellent results, while five reported mild and casual pain. Only one patient reported a mild limitation of range of motion. Conclusions Our results suggest satisfactory overall long-term outcome for the surgical treatment of UBC, although short-and mid-term observation show a considerable rate of recurrence independent of the surgical technique. PMID:22165900

  15. A novel single-step surgical technique for vestibular deepening using laser in conjunction with periodontal flap surgery

    PubMed Central

    Bhardwaj, Ashu; Sultan, Nishat; Sawai, Madhuri; Jafri, Zeba

    2016-01-01

    Moderate-to-severe chronic periodontitis results in clinical loss of attachment, reduced width of attached gingiva (AG), periodontal pockets beyond mucogingival junction (MGJ), gingival recession, loss of alveolar bone, and decreased vestibular depth (VD). The encroachment of frenal and muscle attachments on marginal gingiva increases the rate of progression of periodontal pockets, prevents healing, and causes their recurrence after therapy. Loss of VD and AG associated with continuous progression of pocket formation and bone loss requires two-stage surgical procedures. In this article, one-stage surgical procedure is being described for the first time, to treat the periodontal pockets extending beyond the MGJ by periodontal flap surgery along with vestibular deepening with diode laser to increase the AG. One-step surgical technique is illustrated whereby pocket therapy with reconstruction of lost periodontal tissues can be done along with gingival augmentation by vestibular deepening. PMID:29238149

  16. Non Surgical Correction of Mandibular Deviation and Neuromuscular Coordination after Two years of Mandibular Guidance Therapy: A Case Report.

    PubMed

    Singh, Bijay; Sinha, Nidhi; Sharma, Rohit; Parekh, Narzi

    2015-11-01

    Carcinomas of the mandible may require resection of a segment of bone (continuity defect), partial removal of bone (discontinuity defect), tongue, and floor of the mouth and muscle attachments. Patients undergoing such treatment suffer from facial disfigurement, loss of muscle function, loss of neuromuscular coordination resulting in inability to masticate and swallow acceptably. Surgical reconstruction may not always be possible because of high reoccurrence rate, inability of the patient to cope with another surgery etc. The treatment of choice in non surgical cases is prosthetic rehabilitation using guiding flange prosthesis. This article describes the management of a patient who had undergone hemimandibulectomy and was not willing for a surgical reconstruction. Interim maxillary ramp prosthesis was given to the patient 15 days postoperatively followed by definitive guiding flange prosthesis for two years after which the patient was able to occlude in centric occlusal position without any aid.

  17. Nanotechnology for treating osteoporotic vertebral fractures

    PubMed Central

    Gao, Chunxia; Wei, Donglei; Yang, Huilin; Chen, Tao; Yang, Lei

    2015-01-01

    Osteoporosis is a serious public health problem affecting hundreds of millions of aged people worldwide, with severe consequences including vertebral fractures that are associated with significant morbidity and mortality. To augment or treat osteoporotic vertebral fractures, a number of surgical approaches including minimally invasive vertebroplasty and kyphoplasty have been developed. However, these approaches face problems and difficulties with efficacy and long-term stability. Recent advances and progress in nanotechnology are opening up new opportunities to improve the surgical procedures for treating osteoporotic vertebral fractures. This article reviews the improvements enabled by new nanomaterials and focuses on new injectable biomaterials like bone cements and surgical instruments for treating vertebral fractures. This article also provides an introduction to osteoporotic vertebral fractures and current clinical treatments, along with the rationale and efficacy of utilizing nanomaterials to modify and improve biomaterials or instruments. In addition, perspectives on future trends with injectable bone cements and surgical instruments enhanced by nanotechnology are provided. PMID:26316746

  18. Latest trends in craniomaxillofacial surgical instrumentation.

    PubMed

    Yim, Michael; Demke, Joshua

    2012-08-01

    To review the past year's literature regarding recent innovations in surgical instrumentation for craniomaxillofacial surgery. Current advances in surgical instrumentation have led to many improvements in the field, allowing greater visualization and precision both before and during procedures. One of the common goals is to achieve excellent outcomes with minimal complications, while at the same time minimizing invasiveness of surgery. Highlighted innovations include greater capacities for acquisition of data, leading to improved imaging modalities and expansion of computer-assisted surgical techniques; continued developments in biomaterials used in various reconstructions; and novel uses of bone cutting and bone fixation instrumentation. Technology in the field of craniomaxillofacial surgery is developing rapidly, leading to novel instrumentation being utilized across a broad spectrum of areas. Published data have been encouraging to date, indicating an ever increasing adaptation of these innovations in clinical practice. Future efforts need to focus on cost-benefit analysis and constructing larger-scale studies to better understand effectiveness and patient outcomes.

  19. Biomechanical analysis of iliac crest loading following cortico-cancellous bone harvesting.

    PubMed

    Schmitz, Paul; Cornelius Neumann, Christoph; Neumann, Carsten; Nerlich, Michael; Dendorfer, Sebastian

    2018-05-09

    Iliac crest bone harvesting is a frequently performed surgical procedure widely used to treat bone defects. The objective of this study is to assess the biomechanical quantities related to risk for pelvic fracture after harvesting an autologous bone graft at the anterior iliac crest. Finite element models with a simulated harvest site (sized 15 × 20 mm, 15 × 35 mm, 30 × 20 mm and 30 × 35 mm) in the iliac wing are created. The relevant loading case is when the ipsilateral leg is lifted off the ground. Musculoskeletal analysis is utilized to compute the muscle and joint forces involved in this motion. These forces are used as boundary conditions for the finite element analyses. Bone tissue stress is analyzed. Critical stress peaks are located between the anterior superior iliac spine (ASIS) and the anterior edge of the harvest site. Irrespective of the graft size, the iliac wing does not show any significant stress peaks with the harvest site being 20 to 25 mm posterior to the ASIS. The harvest area itself inhibits the distribution of the forces applied on the ASIS to extend to the posterior iliac wing. This leads to a lack of stress posterior to the harvest site. A balanced stress distribution with no stress peaks appears when the bone graft is taken below the iliac crest. A harvest site located at least 20 to 25 mm posterior to the ASIS should be preferred to minimize the risk of iliac fatigue fracture.

  20. An awake, minimally-invasive, fully-endoscopic surgical technique for treating lumbar radiculopathy secondary to heterotopic foraminal bone formation after a minimally invasive transforaminal lumbar interbody fusion with BMP: technical note

    PubMed Central

    2018-01-01

    One complication associated with recombinant human bone morphogenetic protein (rhBMP-2) use in minimally invasive transforaminal lumbar interbody fusion (MIS-TLIF) is heterotopic bone growth at the neural foramen which results in the compression of neural structures. Here we present an awake, minimally invasive surgical approach for treating the radiculopathy that results from this excessive bone growth in the foramen. A 42-year-old male underwent a lumbar 4–sacral 1 MIS-TLIF by another surgeon. He did well in the initial postoperative period, but he began to note right leg pain and numbness in an L5 dermatomal pattern. The pain continued for 2 years despite interventional pain management, and he began to note left foot dorsiflexion weakness. An electromyography (EMG) showed a left L5 radiculopathy and a CT Lumbar spine demonstrated excessive bone growth in the right L4–5 neural foramen. The patient underwent an awake, endoscopic foraminotomy procedure utilizing a blunt tipped manual shaver drill system. The patient’s radicular symptoms improved immediately, and he remained asymptomatic at the 1 year follow up. Heterotopic foraminal bone growth is one potential complication of rhBMP-2 use in the MIS-TLIF procedure. The endoscopic procedure described here is a minimally invasive surgical option that can be performed in an awake patient and is suggested a unique salvage or rescue procedure to be considered for the treatment of this potential rhBMP-2 complication. PMID:29732437

  1. Long-Term Follow-Up of Primary Medical Versus Surgical Treatment of Prolactinomas in Men: Effects on Hyperprolactinemia, Hypogonadism, and Bone Health.

    PubMed

    Andereggen, Lukas; Frey, Janine; Andres, Robert H; El-Koussy, Marwan; Beck, Jürgen; Seiler, Rolf W; Christ, Emanuel

    2017-01-01

    In men with prolactinomas, impaired bone density is the principle consequence of hyperprolactinemia-induced hypogonadism. Although dopamine agonists (DAs) are the first-line approach in prolactinomas, surgery can be considered in selected cases. In this study, we aimed to investigate the long-term control of hyperprolactinemia, hypogonadism, and bone health comparing primary medical and surgical therapy in men who had not had prior DA treatment. This is a retrospective case-note study of 44 consecutive men with prolactinomas and no prior DAs managed in a single tertiary referral center. Clinical, biochemical, and radiologic response to the first-line approach were analyzed in the 2 cohorts. Mean age at diagnosis was 47 years (range, 22-78 years). The prevalence of hypogonadism was 86%, and 27% of patients had pathologic bone density at baseline. The primary therapeutic strategy was surgery for 34% and DAs for 66% of patients. Median long-term follow-up was 63 months (range, 17-238 months). Long-term control of hyperprolactinemia required DAs in 53% of patients with primary surgical therapy, versus 90% of patients with primary medical therapy (P = 0.02). Hypogonadism was controlled in 73% of patients. The prevalence of patients with pathologic bone density was 37% at last follow-up, with no differences between the 2 therapeutic cohorts (P = 0.48). Despite control of hyperprolactinemia and hypogonadism in most patients independent of the primary treatment modality, the prevalence of impaired bone health status remains high, and osteodensitometry should be recommended. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Evaluation of a setting reaction pathway in the novel composite TiHA-CSD bone cement by FT-Raman and FT-IR spectroscopy

    NASA Astrophysics Data System (ADS)

    Paluszkiewicz, Czesława; Czechowska, Joanna; Ślósarczyk, Anna; Paszkiewicz, Zofia

    2013-02-01

    The aim of this study was to determine a setting reaction pathway in a novel, surgically handy implant material, based on calcium sulfate hemihydrate (CSH) and titanium doped hydroxyapatite (TiHA). The previous studies confirmed superior biological properties of TiHA in comparison to the undoped hydroxyapatite (HA) what makes it highly attractive for future medical applications. In this study the three types of titanium modified HA powders: untreated, calcined at 800 °C, sintered at 1250 °C and CSH were used to produce bone cements. The Fourier Transform-InfraRed (FT-IR) spectroscopy and Raman spectroscopy were applied to evaluate processes taking place during the setting of the studied materials. Our results undoubtedly confirmed that the reaction pathways and the phase compositions differed significantly for set cements and were dependent on the initial heat treatment of TiHA powder. Final materials were multiphase composites consisting of calcium sulfate dihydrate, bassanite, tricalcium phosphate, hydroxyapatite and calcium titanate (perovskite). The FT-IR and Scanning Electron Microscopy (SEM) measurements performed after the incubation of the cement samples in the simulated body fluid (SBF), indicate on high bioactive potential of the obtained bone cements.

  3. Creating an Optimal 3D Printed Model for Temporal Bone Dissection Training.

    PubMed

    Takahashi, Kuniyuki; Morita, Yuka; Ohshima, Shinsuke; Izumi, Shuji; Kubota, Yamato; Yamamoto, Yutaka; Takahashi, Sugata; Horii, Arata

    2017-07-01

    Making a 3-dimensional (3D) temporal bone model is simple using a plaster powder bed and an inkjet printer. However, it is difficult to reproduce air-containing spaces and precise middle ear structures. The objective of this study was to overcome these problems and create a temporal bone model that would be useful both as a training tool and for preoperative simulation. Drainage holes were made to remove excess materials from air-containing spaces, ossicle ligaments were manually changed to bony structures, and small and/or soft tissue structures were colored differently while designing the 3D models. The outcomes were evaluated by 3 procedures: macroscopic and endoscopic inspection of the model, comparison of computed tomography (CT) images of the model to the original CT, and assessment of tactile sensation and reproducibility by 20 surgeons performing surgery on the model. Macroscopic and endoscopic inspection, CT images, and assessment by surgeons were in agreement in terms of reproducibility of model structures. Most structures could be reproduced, but the stapes, tympanic sinus, and mastoid air cells were unsatisfactory. Perioperative tactile sensation of the model was excellent. Although this model still does not embody perfect reproducibility, it proved sufficiently practical for use in surgical training.

  4. Accuracy of three different types of stereolithographic surgical guide in implant placement: an in vitro study.

    PubMed

    Turbush, Sarah Katherine; Turkyilmaz, Ilser

    2012-09-01

    Precise treatment planning before implant surgery is necessary to identify vital structures and to ensure a predictable restorative outcome. The purpose of this study was to compare the accuracy of implant placement by using 3 different types of surgical guide: bone-supported, tooth-supported, and mucosa-supported. Thirty acrylic resin mandibles were fabricated with stereolithography (SLA) based on data from the cone beam computerized tomography (CBCT) scan of an edentulous patient. Ten of the mandibles were modified digitally before fabrication with the addition of 4 teeth, and 10 of the mandibles were modified after fabrication with soft acrylic resin to simulate mucosa. Each acrylic resin mandible had 5 implants virtually planned in a 3-D software program. A total of 150 implants were planned and placed by using SLA guides. Presurgical and postsurgical CBCT scans were superimposed to compare the virtual implant placement with the actual implant placement. For statistical analyses, a linear mixed models approach and t-test with the 2-sided alpha level set at .016 were used. All reported P values were adjusted by the Dunn-Sidak method to control the Type I error rate across multiple pairwise comparisons. The mean angular deviation of the long axis between the planned and placed implants was 2.2 ±1.2 degrees; the mean deviations in linear distance between the planned and placed implants were 1.18 ±0.42 mm at the implant neck and 1.44 ±0.67 mm at the implant apex for all 150 implants. After the superimposition procedure, the angular deviation of the placed implants was 2.26 ±1.30 degrees with the tooth-supported, 2.17 ±1.02 degrees with the bone-supported, and 2.29 ±1.28 degrees with the mucosa-supported SLA guide. The mean deviations in linear distance between the planned and placed implants at the neck and apex were 1.00 ±0.33 mm and 1.15 ±0.42 mm for the tooth-supported guides; 1.08 ±0.33 mm and 1.53 ±0.90 mm for the bone-supported guides; and 1.47 ±0.43 mm and 1.65 ±0.48 mm for the mucosa-supported SLA surgical guides. The results of this study show that stereolithographic surgical guides may be reliable in implant placement and that: 1) there was no statistically significant difference among the 3 types of guide when comparing angular deviation and 2) mucosa-supported guides were less accurate than both tooth-supported and bone-supported guides for linear deviation at the implant neck and apex. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  5. Surgical correction of severe strabismus and enophthalmos secondary to zygomatic arch fracture in a dog.

    PubMed

    Konrade, Kricket A; Clode, Alison B; Michau, Tammy M; Roe, Simon C; Trumpatori, Brian J; Krug, William V; Gilger, Brian C

    2009-01-01

    A grossly displaced segmental zygomatic arch fracture with marked ventro-lateral deviation of the left globe was diagnosed in a 3-month-old male German Shepherd dog following a bite injury. The fracture was approached via a modified lateral orbitotomy and a fragment of the lacrimal bone removed. The rostral portion of the fracture was stabilized with a 5-hole 2.0 dynamic compression plate bone plate. The surgical correction achieved sufficient skeletal fixation for proper anatomical reduction of the globe and excellent cosmetic and functional outcomes.

  6. A rare case of chondroblastoma of the acromion.

    PubMed

    Arıkan, Murat; Toğral, Güray; Yıldırım, Ahmet; Irkkan, Çiğdem

    2016-12-01

    We present a 37-year-old patient with a chondroblastoma in his right acromion. The acromion is an unusual site for this type of tumor and the typical surgical treatment involves resection of the involved acromion bone. The patient was surgically treated with resection of the right acromion and autogenous iliac bone grafting. Twenty five months postoperatively, he demonstrated full shoulder function, without evidence of local recurrence or metastasis. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  7. Antibiotics in frozen bone grafts can cause allergic reactions in recipient patients.

    PubMed

    Crnogaca, Kresimir; Bicanic, Goran; Delimar, Domagoj

    2015-02-01

    Antibiotic prophylaxis is a routine procedure during total hip arthroplasty (THA), and the vast majority of cadavers within the multitissue procurement receive one or more antibiotics. Upon harvesting, bone grafts are stored in the bone banks on the temperature as low as -80°C for up to 5 years. It is shown in the literature that the antibiotics remain active and viable in the bone grafts even after being exposed to extremely low temperatures in the prolonged periods. Possibility of remnant antibiotic concentrations in the bone grafts and the fact that these antibiotic remnants maintain active even after being exposed to extremely low temperatures create the environment in which the possibility for the allergic reaction in sensitive patient receiving bone graft exists. We hypothesize that harvested bone grafts containing active antibiotic substance have the potential for local and systemic allergic reaction in sensitive recipient patients thus increasing morbidity and the costs of the treatment. Allergic reactions can mimic surgical site infections as well with the consequent substantial pitfalls in the treatment. Following that, in the setting of an assumed but not confirmed surgical site infection, the immunological evaluation on antibiotics for recipients of bone grafts could be added to the standard diagnostic algorithms. In addition, bone banks should be obliged to provide information of all potential drugs that can be found in every specific bone graft to the end users. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study

    PubMed Central

    Harrysson, Ola LA; Hosni, Yasser A; Nayfeh, Jamal F

    2007-01-01

    Background Conventional knee and hip implant systems have been in use for many years with good success. However, the custom design of implant components based on patient-specific anatomy has been attempted to overcome existing shortcomings of current designs. The longevity of cementless implant components is highly dependent on the initial fit between the bone surface and the implant. The bone-implant interface design has historically been limited by the surgical tools and cutting guides available; and the cost of fabricating custom-designed implant components has been prohibitive. Methods This paper describes an approach where the custom design is based on a Computed Tomography scan of the patient's joint. The proposed design will customize both the articulating surface and the bone-implant interface to address the most common problems found with conventional knee-implant components. Finite Element Analysis is used to evaluate and compare the proposed design of a custom femoral component with a conventional design. Results The proposed design shows a more even stress distribution on the bone-implant interface surface, which will reduce the uneven bone remodeling that can lead to premature loosening. Conclusion The proposed custom femoral component design has the following advantages compared with a conventional femoral component. (i) Since the articulating surface closely mimics the shape of the distal femur, there is no need for resurfacing of the patella or gait change. (ii) Owing to the resulting stress distribution, bone remodeling is even and the risk of premature loosening might be reduced. (iii) Because the bone-implant interface can accommodate anatomical abnormalities at the distal femur, the need for surgical interventions and fitting of filler components is reduced. (iv) Given that the bone-implant interface is customized, about 40% less bone must be removed. The primary disadvantages are the time and cost required for the design and the possible need for a surgical robot to perform the bone resection. Some of these disadvantages may be eliminated by the use of rapid prototyping technologies, especially the use of Electron Beam Melting technology for quick and economical fabrication of custom implant components. PMID:17854508

  9. Non-photorealistic rendering of virtual implant models for computer-assisted fluoroscopy-based surgical procedures

    NASA Astrophysics Data System (ADS)

    Zheng, Guoyan

    2007-03-01

    Surgical navigation systems visualize the positions and orientations of surgical instruments and implants as graphical overlays onto a medical image of the operated anatomy on a computer monitor. The orthopaedic surgical navigation systems could be categorized according to the image modalities that are used for the visualization of surgical action. In the so-called CT-based systems or 'surgeon-defined anatomy' based systems, where a 3D volume or surface representation of the operated anatomy could be constructed from the preoperatively acquired tomographic data or through intraoperatively digitized anatomy landmarks, a photorealistic rendering of the surgical action has been identified to greatly improve usability of these navigation systems. However, this may not hold true when the virtual representation of surgical instruments and implants is superimposed onto 2D projection images in a fluoroscopy-based navigation system due to the so-called image occlusion problem. Image occlusion occurs when the field of view of the fluoroscopic image is occupied by the virtual representation of surgical implants or instruments. In these situations, the surgeon may miss part of the image details, even if transparency and/or wire-frame rendering is used. In this paper, we propose to use non-photorealistic rendering to overcome this difficulty. Laboratory testing results on foamed plastic bones during various computer-assisted fluoroscopybased surgical procedures including total hip arthroplasty and long bone fracture reduction and osteosynthesis are shown.

  10. Enhanced tendon-to-bone repair through adhesive films.

    PubMed

    Linderman, Stephen W; Golman, Mikhail; Gardner, Thomas R; Birman, Victor; Levine, William N; Genin, Guy M; Thomopoulos, Stavros

    2018-04-01

    Tendon-to-bone surgical repairs have unacceptably high failure rates, possibly due to their inability to recreate the load transfer mechanisms of the native enthesis. Instead of distributing load across a wide attachment footprint area, surgical repairs concentrate shear stress on a small number of suture anchor points. This motivates development of technologies that distribute shear stresses away from suture anchors and across the enthesis footprint. Here, we present predictions and proof-of-concept experiments showing that mechanically-optimized adhesive films can mimic the natural load transfer mechanisms of the healthy attachment and increase the load tolerance of a repair. Mechanical optimization, based upon a shear lag model corroborated by a finite element analysis, revealed that adhesives with relatively high strength and low stiffness can, theoretically, strengthen tendon-to-bone repairs by over 10-fold. Lap shear testing using tendon and bone planks validated the mechanical models for a range of adhesive stiffnesses and strengths. Ex vivo human supraspinatus repairs of cadaveric tissues using multipartite adhesives showed substantial increase in strength. Results suggest that adhesive-enhanced repair can improve repair strength, and motivate a search for optimal adhesives. Current surgical techniques for tendon-to-bone repair have unacceptably high failure rates, indicating that the initial repair strength is insufficient to prevent gapping or rupture. In the rotator cuff, repair techniques apply compression over the repair interface to achieve contact healing between tendon and bone, but transfer almost all force in shear across only a few points where sutures puncture the tendon. Therefore, we evaluated the ability of an adhesive film, implanted between tendon and bone, to enhance repair strength and minimize the likelihood of rupture. Mechanical models demonstrated that optimally designed adhesives would improve repair strength by over 10-fold. Experiments using idealized and clinically-relevant repairs validated these models. This work demonstrates an opportunity to dramatically improve tendon-to-bone repair strength using adhesive films with appropriate material properties. Copyright © 2018 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  11. Forced-air patient warming blankets disrupt unidirectional airflow.

    PubMed

    Legg, A J; Hamer, A J

    2013-03-01

    We have recently shown that waste heat from forced-air warming blankets can increase the temperature and concentration of airborne particles over the surgical site. The mechanism for the increased concentration of particles and their site of origin remained unclear. We therefore attempted to visualise the airflow in theatre over a simulated total knee replacement using neutral-buoyancy helium bubbles. Particles were created using a Rocket PS23 smoke machine positioned below the operating table, a potential area of contamination. The same theatre set-up, warming devices and controls were used as in our previous study. This demonstrated that waste heat from the poorly insulated forced-air warming blanket increased the air temperature on the surgical side of the drape by > 5°C. This created convection currents that rose against the downward unidirectional airflow, causing turbulence over the patient. The convection currents increased the particle concentration 1000-fold (2 174 000 particles/m(3) for forced-air warming vs 1000 particles/m(3) for radiant warming and 2000 particles/m(3) for the control) by drawing potentially contaminated particles from below the operating table into the surgical site. Cite this article: Bone Joint J 2013;95-B:407-10.

  12. Nonintrusive 3D reconstruction of human bone models to simulate their bio-mechanical response

    NASA Astrophysics Data System (ADS)

    Alexander, Tsouknidas; Antonis, Lontos; Savvas, Savvakis; Nikolaos, Michailidis

    2012-06-01

    3D finite element models representing functional parts of the human skeletal system, have been repeatedly introduced over the last years, to simulate biomechanical response of anatomical characteristics or investigate surgical treatment. The reconstruction of geometrically accurate FEM models, poses a significant challenge for engineers and physicians, as recent advances in tissue engineering dictate highly customized implants, while facilitating the production of alloplast materials that are employed to restore, replace or supplement the function of human tissue. The premises of every accurate reconstruction method, is to encapture the precise geometrical characteristics of the examined tissue and thus the selection of a sufficient imaging technique is of the up-most importance. This paper reviews existing and potential applications related to the current state-of-the-art of medical imaging and simulation techniques. The procedures are examined by introducing their concepts; strengths and limitations, while the authors also present part of their recent activities in these areas. [Figure not available: see fulltext.

  13. [Research on Energy Distribution During Osteoarthritis Treatment Using Shock Wave Lithotripsy].

    PubMed

    Zhang, Shinian; Wang, Xiaofeng; Zhang, Dong

    2015-04-01

    Extracorporeal shock wave treatment is capable of providing a non-surgical and effective treatment modality for patients suffering from osteoarthritis. The major objective of current works is to investigate how the shock wave (SW) field would change if a bony structure exists in the path of the acoustic wave. Firstly, a model of finite element method (FEM) was developed based on Comsol software in the present study. Then, high-speed photography experiments were performed to record cavitation bubbles with the presence of mimic bone. On the basis of comparing experimental with simulated results, the effectiveness of FEM model could be verified. Finally, the energy distribution during extracorporeal shock wave treatment was predicted. The results showed that the shock wave field was deflected with the presence of bony structure and varying deflection angles could be observed as the bone shifted up in the z-direction relative to shock wave geometric focus. Combining MRI/CT scans to FEM modeling is helpful for better standardizing the treatment dosage and optimizing treatment protocols in the clinic.

  14. Lidocaine Concentration in Mandibular Bone After Subperiosteal Infiltration Anesthesia Decreases With Elevation of Periosteal Flap and Irrigation With Saline

    PubMed Central

    Ogawa, Sachie; Watanabe, Masahiro; Kawaai, Hiroyoshi; Tada, Hitoshi; Yamazaki, Shinya

    2014-01-01

    It has been reported that the action of infiltration anesthesia on the jawbone is attenuated significantly by elevation of the periosteal flap with saline irrigation in clinical studies; however, the reason is unclear. Therefore, the lidocaine concentration in mandibular bone after subperiosteal infiltration anesthesia was measured under several surgical conditions. The subjects were 48 rabbits. Infiltration anesthesia by 0.5 mL of 2% lidocaine with 1 : 80,000 epinephrine (adrenaline) was injected into the right mandibular angle and left mandibular body, respectively. Under several surgical conditions (presence or absence of periosteal flap, and presence or absence of saline irrigation), both mandibular bone samples were removed at a fixed time after subperiosteal infiltration anesthesia. The lidocaine concentration in each mandibular bone sample was measured by high-performance liquid chromatography. As a result, elevation of the periosteal flap with saline irrigation significantly decreased the lidocaine concentration in the mandibular bone. It is suggested that the anesthetic in the bone was washed out by saline irrigation. Therefore, supplemental conduction and/or general anesthesia should be utilized for long operations that include elevation of the periosteal flap with saline irrigation. PMID:24932978

  15. Emerging Perspectives in Scaffold for Tissue Engineering in Oral Surgery

    PubMed Central

    Presta, Rossella

    2017-01-01

    Bone regeneration is currently one of the most important and challenging tissue engineering approaches in regenerative medicine. Bone regeneration is a promising approach in dentistry and is considered an ideal clinical strategy in treating diseases, injuries, and defects of the maxillofacial region. Advances in tissue engineering have resulted in the development of innovative scaffold designs, complemented by the progress made in cell-based therapies. In vitro bone regeneration can be achieved by the combination of stem cells, scaffolds, and bioactive factors. The biomimetic approach to create an ideal bone substitute provides strategies for developing combined scaffolds composed of adult stem cells with mesenchymal phenotype and different organic biomaterials (such as collagen and hyaluronic acid derivatives) or inorganic biomaterials such as manufactured polymers (polyglycolic acid (PGA), polylactic acid (PLA), and polycaprolactone). This review focuses on different biomaterials currently used in dentistry as scaffolds for bone regeneration in treating bone defects or in surgical techniques, such as sinus lift, horizontal and vertical bone grafts, or socket preservation. Our review would be of particular interest to medical and surgical researchers at the interface of cell biology, materials science, and tissue engineering, as well as industry-related manufacturers and researchers in healthcare, prosthetics, and 3D printing, too. PMID:28337223

  16. Unicameral bone cyst: a retrospective study of three surgical treatments.

    PubMed

    Sung, Anthony D; Anderson, Megan E; Zurakowski, David; Hornicek, Francis J; Gebhardt, Mark C

    2008-10-01

    Between 1979 and 2004, 167 patients younger than 20 years were treated surgically for humeral or femoral unicameral bone cysts with either injection of corticosteroids (steroids), curettage plus bone grafting (curettage), or a combination injection of steroids, demineralized bone matrix, and bone marrow aspirate (SDB) at Children's Hospital of Boston and Massachusetts General Hospital (mean followup, 7.3 years; range, 1 month-27 years). Outcomes included treatment failure (defined clinically as subsequent pathologic fracture or need for retreatment to prevent pathologic fracture) and complications. Information was obtained from medical records and by telephone questionnaire. After one treatment, 84% of cysts treated with steroids experienced failed treatment versus 64% with curettage and 50% with SDB. For unicameral bone cysts requiring retreatment (regardless of first treatment), 76% retreated with steroids had failed treatment versus 63% with curettage and 71% with SDB. Curettage was associated with the lowest rate of posttreatment pathologic fractures and highest rate of pain and other complications. Multivariate logistic regression indicated treatment with steroids alone and younger age were independent predictors of failure. We believe SDB is a reasonable first treatment for unicameral bone cysts in the humerus and femur in patients younger than 20 years, being less invasive yet comparable to curettage in preventing recurrence.

  17. [Recent advances in treatment of aseptic femoral shaft nonunion].

    PubMed

    Zhang, Wei; Chen, Hua; Tang, Peifu

    2018-05-01

    To review the recent advances in treatment of aseptic femoral shaft nonunion. The clinical studies about the treatments of aseptic femoral shaft nonunion in recent years were widely reviewed and analyzed. There are several surgical methods for aseptic femoral shaft nonunion. Due to uncertain clinical outcome, dynamization of nail should be carefully selected. The exchange nailing is suitable for the hypertrophic nonunion of the isthmal femoral shaft fracture. The exchange lateral plating is suitable for nonunion with obvious malformation. However, wave plate or dual plate should be chosen when the bone nonuinon is combined with the medial defect. The augmentation plating improves the success rate of nailing for femoral shaft nonunion, but it should be carefully selected for patients with obvious deformity or bone defect. Ilizarov technique is suitable for various bone nonunion, especially with complicated or large segmental bone defects. Induced membrane technique is also an important method for the treatment of bone nonunion with large bone defects. The clinical efficacy of the blocking screw remains to be supported by further evidence. Biological stimulants are mainly used for atrophic nonunion, and the clinical efficacy of them alone are still controversial. Due to lack of comparative studies between different surgical methods, the orthopedist should choose the appropriate treatment according to the individual situations of the patient and the types of bone nonunion.

  18. Co-occurence of florid cemento-osseous dysplasia and simple bone cyst: a case report.

    PubMed

    Rao, Kumuda Arvind; Shetty, Shishir Ram; Babu, Subhas G; Castelino, Renita Lorina

    2011-01-01

    The purpose of this report is to present a rare case of co-occurrence of florid cemento-osseous dysplasia with simple bone cyst in a middle aged Asian woman. Most of the reported cases are isolated cases of simple bone cyst or florid cemento-osseous dysplasia, but co-occurrence of these two entities is extremely rare. The authors report a 41 year old female patient with co-occurrence of mandibular florid cemento-osseous dysplasia with simple bone cyst. A thorough clinical and radiological examination was carried out. It was diagnosed mandibular cyst with possible co-occurrence of florid cemento-osseous dysplasia. Surgical exploration of the multilocular lesion was applied. Since, the patient was symptomatic at the time of presentation utmost caution was taken during the surgical procedure as florid cemento-osseous dysplasia is associated with hypo-vascularity of the affected bone. Based on histopathological, as well as supporting clinico-radiological findings a confirmative diagnosis of florid cemento-osseous dysplasia co-occurring with simple bone cyst was made. Patient was followed-up for a period of six months and was reported to be asymptomatic. Timely diagnosis and well planned treatment is important to obtain a good prognosis when a rare co-occurrence of two or more bone lesions affects the jaws.

  19. One-stage tooth-borne distraction versus two stage bone-borne distraction in surgically assisted maxillary expansion (SARME).

    PubMed

    Seeberger, Robin; Abe-Nickler, Dorothee; Hoffmann, Jürgen; Kunzmann, Kevin; Zingler, Sebastian

    2015-12-01

    To evaluate and compare the effects of tooth-borne and bone-borne distraction devices in surgically assisted maxillary expansion (SARME) on dental and skeletal structures. A sample of 33 skeletally mature patients with transverse maxillary deficiencies was examined with cone beam computed tomography (CBCT) before and 3 months after surgery. Fourteen patients were treated with tooth-borne devices and 19 patients with bone-borne devices. Dental crown expansion in the first premolars did not differ significantly between the two groups, and median expansion was 5.55 mm (interquartile range [IQR] 5.23) in the tooth-borne device group and 4.6 mm (IQR 3.4) in the bone-borne device group. In the first molars, crown expansion and lateral tipping were significantly greater in the tooth-borne device group (P ≤ .02). The median skeletal nasal isthmus increase was significantly more in the bone-borne device group at 3.0 mm than in the tooth-borne device group at 0.98 mm (P ≤ .02). Both tooth-borne and bone-borne devices are effective treatment modalities to correct maxillary transverse deficiencies. Bone-borne devices produced greater widening of the skeletal nasal floor and fewer dental side effects in the first molars. Copyright © 2015 Elsevier Inc. All rights reserved.

  20. Cell culture-based tissue engineering as an alternative to bone grafts in implant dentistry: a literature review.

    PubMed

    Boeckel, Daniel Gonçalves; Shinkai, Rosemary Sadami Arai; Grossi, Márcio Lima; Teixeira, Eduardo Rolim

    2012-09-01

    Several biomaterials and techniques for bone grafting have been described in the literature for atresic bone tissue replacement caused by edentulism, surgical resectioning, and traumas. A new technique involves tissue engineering, a promising option to replace bone tissue and solve problems associated with morbidity of autogenous grafting. This literature review aims to describe tissue-engineering techniques using ex vivo cell culture as an alternative to repair bone maxillary atresias and discuss the concepts and potentials of bone regeneration through cell culture techniques as an option for restorative maxillofacial surgery.

  1. A development of surgical simulator for training of operative skills using patient-specific data.

    PubMed

    Ogata, Masato; Nagasaka, Manabu; Inuiya, Toru; Makiyama, Kazuhide; Kubota, Yoshinobu

    2011-01-01

    At the Advanced Medical Research Center at Yokohama City University School of Medicine, we have been developing a practical surgical simulator for renal surgery. Unlike already commercialized laparoscopic surgical simulators, our surgical simulator is capable of using patient-specific models for preoperative training and improvement of laparoscopic surgical skills. We have been evaluating the simulator clinically with the aim of using it in renal surgery training at Yokohama City University Hospital. The simulator can be applied to other types of laparoscopic surgery, such as gynecological, thoracic, and gastrointestinal. Here, we report on the technical aspects of the simulator.

  2. Dynamic Simulation of Three Dimensional Architectural and Mechanical Alterations in Human Trabecular Bone during Menopause

    PubMed Central

    Liu, X. Sherry; Huang, Angela H.; Zhang, X. Henry; Sajda, Paul; Ji, Baohua; Guo, X. Edward

    2008-01-01

    A three dimensional (3D) computational simulation of dynamic process of trabecular bone remodeling was developed with all the parameters derived from physiological and clinical data. Contributions of the microstructural bone formation deficits: trabecular plate perforations, trabecular rod breakages, and isolated bone fragments, to the rapid bone loss and disruption of trabecular microarchitecture during menopause were studied. Eighteen human trabecular bone samples from femoral neck (FN) and spine were scanned using a micro computed tomography (μCT) system. Bone resorption and formation were simulated as a computational cycle corresponding to 40-day resorption/160-day formation. Resorption cavities were randomly created over the bone surface according to the activation frequency, which was strictly based on clinical data. Every resorption cavity was refilled during formation unless it caused trabecular plate perforation, trabecular rod breakage or isolated fragments. A 20-year-period starting 5 years before and ending 15 years after menopause was simulated for each specimen. Elastic moduli, standard and individual trabeculae segmentation (ITS)-based morphological parameters were evaluated for each simulated 3D image. For both spine and FN groups, the time courses of predicted bone loss pattern by microstructural bone formation deficits were fairly consistent with the clinical measurements. The percentage of bone loss due to trabecular plate perforation, trabecular rod breakage, and isolated bone fragments were 73.2%, 18.9% and 7.9% at the simulated 15 years after menopause. The ITS-based plate fraction (pBV/BV), mean plate surface area (pTb.S), plate number density (pTb.N), and mean rod thickness (rTb.Th) decreased while rod fraction (rBV/BV) and rod number density (rTb.N) increased after the simulated menopause. The dynamic bone remodeling simulation based on microstructural bone formation deficits predicted the time course of menopausal bone loss pattern of spine and FN. Microstructural plate perforation could be the primary cause of menopausal trabecular bone loss. The combined effect of trabeculae perforation, breakage, and isolated fragments resulted in fewer and smaller trabecular plates and more but thinner trabecular rods. PMID:18550463

  3. Effect of 1% sodium alendronate in the non-surgical treatment of periodontal intraosseous defects: a 6-month clinical trial

    PubMed Central

    DUTRA, Bernardo Carvalho; OLIVEIRA, Alcione Maria Soares Dutra; OLIVEIRA, Peterson Antônio Dutra; MANZI, Flavio Ricardo; CORTELLI, Sheila Cavalca; COTA, Luís Otávio de Miranda; COSTA, Fernando Oliveira

    2017-01-01

    Abstract Background and objectives Few studies have evaluated the effect of the topical application of sodium alendronate (ALN) on the treatment of intrabuccal bone defects, especially those caused by periodontitis. This 6-month randomized placebo controlled clinical trial aimed at evaluating the effect of non-surgical periodontal treatment associated with the use of 1% ALN, through clinical evaluations and cone-beam computed tomography (CBCT). Material and Methods Twenty individuals with chronic periodontitis underwent periodontal examination at the baseline as well as 3 and 6 months after periodontal treatment, registering clinical attachment level (CAL), periodontal probing depth (PPD), and bleeding on probing (BOP) as the clinical outcomes. After manual scaling and root planing, 40 bilateral sites with interproximal vertical bone defects were randomly treated with either 1% ALN gel or a placebo. Bone defects were evaluated through CBCT at the baseline and 6 months post-treatment. The clinical and CBCT parameters were compared using the Wilcoxon and Friedman tests (p<0.05). Results Although ALN produced a greater CAL gain when compared to the placebo at 6 months post-treatment (p=0.021), both treatments produced similar effects on the PPD, BOP, and bone height. Significant differences in bone fill were observed only in patients of the ALN group (4.5 to 3.8 mm; p=0.003) at 6 months post-treatment. Conclusions Topical application of 1% ALN might be a beneficial adjuvant to non-surgical periodontal therapy. PMID:28678950

  4. A comparative investigation of bone surface after cutting with mechanical tools and Er:YAG laser.

    PubMed

    Baek, Kyung-Won; Deibel, Waldemar; Marinov, Dilyan; Griessen, Mathias; Dard, Michel; Bruno, Alfredo; Zeilhofer, Hans-Florian; Cattin, Philippe; Juergens, Philipp

    2015-07-01

    Despite of the long history of medical application, laser ablation of bone tissue became successful only recently. Laser bone cutting is proven to have higher accuracy and to increase bone healing compared to conventional mechanical bone cutting. But the reason of subsequent better healing is not biologically explained yet. In this study we present our experience with an integrated miniaturized laser system mounted on a surgical lightweight robotic arm. An Erbium-doped Yttrium Aluminium Garnet (Er:YAG) laser and a piezoelectric (PZE) osteotome were used for comparison. In six grown up female Göttingen minipigs, comparative surgical interventions were done on the edentulous mandibular ridge. Our laser system was used to create different shapes of bone defects on the left side of the mandible. On the contralateral side, similar bone defects were created by PZE osteotome. Small bone samples were harvested to compare the immediate post-operative cut surface. The analysis of the cut surface of the laser osteotomy and conventional mechanical osteotomy revealed an essential difference. The scanning electron microscopy (SEM) analysis showed biologically open cut surfaces from the laser osteotomy. The samples from PZE osteotomy showed a flattened tissue structure over the cut surface, resembling the "smear layer" from tooth preparation. We concluded that our new finding with the mechanical osteotomy suggests a biological explanation to the expected difference in subsequent bone healing. Our hypothesis is that the difference of surface characteristic yields to different bleeding pattern and subsequently results in different bone healing. The analyses of bone healing will support our hypothesis. © 2015 Wiley Periodicals, Inc.

  5. SURGICAL TREATMENT OF UPPER AND MIDDLE FACIAL ZONE TRAUMAS IN PROGRESS OF CONCOMITANT TRAUMATIC CRANIOFACIAL INJURIES.

    PubMed

    Lagvilava, G; Gvenetadze, Z; Toradze, G; Devidze, I; Gvenetadze, G

    2015-09-01

    In 2012-2015, 207 patients with concomitant craniofacial injuries, who underwent surgical treatment, were observed; among them 176 were men and 31- women. Age of the patients ranged from 16 to 60 years. According to localization and severity of trauma and a priority of surgical intervention, the patients conventionally were divided into 3 groups by the authors: I group (65 patients) - craniofacial injuries; the skull as well as upper and middle areas of face (subcranial and frontobasal fractures) were affected (fractured). II group (80 patients) - severe traumatic injuries of upper and especially middle zones of the face, accompanied with closed craniocerebral trauma, no need in neurosurgery. III group (62 patients) -on the background of serious head traumas, the injuries of face bones were less severe (injury of one or two anatomic areas with displacement of fractured fragments but without bone tissue defects) According to the obtained results a priority was always given to the neurosurgery (vital testimony).The reconstructive surgeries on face skeleton was conducted in combination involving neurosurgeons (I group patients). Reconstructive surgeries of facial bones were conducted in the patients of II group, immediately or at primary deferred period of time but in the patients of III group the surgical procedures for removal of early secondary or traumatic residual fractures have been performed. Reposition of the fractured facial bone fragments was performed in an open way and fixation was carried out by titanium plates and mesh cage (at bone tissue defect). For prevention and elimination of post-traumatic inflammatory processes, the final stage of surgical intervention was: sanation of nasal accessory sinuses and catheterization (5-7 days) of external carotid arteries for administration of antibiotics and other medical preparations. Early and differentiated approach to face injuries, worsening in the course of craniocephalic trauma was not revealed in any patient; there was no evidence of development inflammatory processes in traumatic regions; esthetic and functional results obtained after the surgeries of maxillofacial area were assessed as good and satisfactory.

  6. Effect of Real-Time Feedback on Screw Placement Into Synthetic Cancellous Bone.

    PubMed

    Gustafson, Peter A; Geeslin, Andrew G; Prior, David M; Chess, Joseph L

    2016-08-01

    The objective of this study is to evaluate whether real-time torque feedback may reduce the occurrence of stripping when inserting nonlocking screws through fracture plates into synthetic cancellous bone. Five attending orthopaedic surgeons and 5 senior level orthopaedic residents inserted 8 screws in each phase. In phase I, screws were inserted without feedback simulating conventional techniques. In phase II, screws were driven with visual torque feedback. In phase III, screws were again inserted with conventional techniques. Comparison of these 3 phases with respect to screw insertion torque, surgeon rank, and perception of stripping was used to establish the effects of feedback. Seventy-three of 239 screws resulted in stripping. During the first phase, no feedback was provided and the overall strip rate was 41.8%; this decreased to 15% with visual feedback (P < 0.001) and returned to 35% when repeated without feedback. With feedback, a lower average torque was applied over a narrower torque distribution. Residents stripped 40.8% of screws compared with 20.2% for attending surgeons. Surgeons were poor at perceiving whether they stripped. Prevention and identification of stripping is influenced by surgeon perception of tactile sensation. This is significantly improved with utilization of real-time visual feedback of a torque versus roll curve. This concept of real-time feedback seems beneficial toward performance in synthetic cancellous bone and may lead to improved fixation in cancellous bone in a surgical setting.

  7. A fatal case of bone marrow embolism of unknown cause masquerading clinically as dengue shock syndrome.

    PubMed

    Selvi, Subramanian Kalaivani; Kar, Rakhee; Vadivelan, Mehalingam; Subrahmanyam, Dharanipragada Krishna Suri

    2012-01-01

    Bone marrow fat embolism usually occurs following multiple bone fractures, intraosseous surgical procedures, following vigorous cardiac resuscitation, ecclampsia, sickle cell anemia, malignancies, etc. We present a case of 70-year-old male who presented with fever, cough with expectoration, respiratory distress, altered sensorium, hypotension and thrombocytopenia, and diagnosed to have dengue shock syndrome and expired within 1 day of admission. Postmortem lung biopsy revealed bone marrow fat embolism.

  8. A simplified protocol for banking bone from surgical donors requiring a 90-day quarantine and an HIV-1 antibody test.

    PubMed

    La Prairie, A J; Gross, M

    1991-02-01

    The banking of femoral heads from patients who undergo total hip arthroplasty provides a valuable resource for orthopedic surgery. Quality assurance of the banked bone used in clinical procedures requires documented policies for screening, procuring, storing and distributing. Potential donors are screened at the time of donation for malignant disease, possible communicable disease, sepsis and high-risk life-styles. After negative culture results are confirmed and appropriate documentation has been completed, the bone is frozen at -70 degrees C. A quarantine period of 90 days follows. The donor is followed up 90 days or more postoperatively. At that time written consent is obtained for donation of the recovered tissue to the bone bank and for serology testing for human immunodeficiency virus (HIV-1) antibody, hepatitis B surface antigen (HBsAG), hepatitis B core antibody (HBcAb) and syphilis, and the donor is rescreened for contraindications. This protocol meets or exceeds all existing standards. The combination of obtaining consent and serology testing at 90 days streamlines the logistics of banking bone from surgical donors.

  9. Bone banking.

    PubMed

    Howard, W

    1999-04-01

    The use of human organs and tissues for transplantation in Australia has increased significantly over the past 30 years. In 1997, the Australian Coordinating Committee on Organ Registries and Donation (ACCORD) reported a total number of 190 organ donors, 636 corneal donors and 1509 bone donors Australia wide. Of the 1509 bone donations, 143 came from cadaveric sources and 1366 were made by living donors. Bone transplantation is not as widely recognised as solid organ or corneal transplantation. Due to improved technology and surgical skills, the demand for bone transplantation has increased markedly. This Clinical Update will provide an overview of the physiological aspects of bone transplantation and explore bone banking, a key step in the complex and critical process of bone transplantation.

  10. Virtual reality simulator: demonstrated use in neurosurgical oncology.

    PubMed

    Clarke, David B; D'Arcy, Ryan C N; Delorme, Sebastien; Laroche, Denis; Godin, Guy; Hajra, Sujoy Ghosh; Brooks, Rupert; DiRaddo, Robert

    2013-04-01

    The overriding importance of patient safety, the complexity of surgical techniques, and the challenges associated with teaching surgical trainees in the operating room are all factors driving the need for innovative surgical simulation technologies. Despite these issues, widespread use of virtual reality simulation technology in surgery has not been fully implemented, largely because of the technical complexities in developing clinically relevant and useful models. This article describes the successful use of the NeuroTouch neurosurgical simulator in the resection of a left frontal meningioma. The widespread application of surgical simulation technology has the potential to decrease surgical risk, improve operating room efficiency, and fundamentally change surgical training.

  11. Papineau debridement, Ilizarov bone transport, and negative-pressure wound closure for septic bone defects of the tibia.

    PubMed

    Karargyris, Orestis; Polyzois, Vasilios D; Karabinas, Panayiotis; Mavrogenis, Andreas F; Pneumaticos, Spyros G

    2014-08-01

    Ilizarov pioneered bone transport using a circular external fixator. Papineau described a staged technique for the treatment for infected pseudarthrosis of the long bones. This article presents a single-stage Papineau technique and Ilizarov bone transport, and postoperative negative-pressure wound dressing changes for septic bone defects of the tibia. We studied the files of seven patients (mean age, 32 years) with septic bone defects of the tibia treated with a Papineau technique and Ilizarov bone transport in a single stage, followed by postoperative negative-pressure wound dressing changes. All patients had septic pseudarthrosis and skin necrosis of the tibia. The technique included a single-stage extensive surgical debridement of necrotic bone, open bone grafting with cancellous bone autograft and bone transport, and postoperative negative-pressure wound dressing changes for wound closure. The mean time from the initial injury was 6 months (range, 4-8 months). The mean follow-up was 14 months (range, 10-17 months). All patients experienced successful wound healing at a mean of 29 days. Six patients experienced successful bone regeneration and union at the docking side at a mean of 6 months. One patient experienced delayed union at the docking site, which was treated with autologous cancellous bone grafting. Two patients experienced pin track infection, which was successfully treated with antibiotics and pin site dressing changes. All patients were able to return to their work and previous levels of activity, except one patient who had a stiff ankle joint and had to change his job. No patient experienced recurrence of infection, or fracture of the regenerated or transported bone segment until the period of this study. The combined Papineau and Ilizarov bone transport technique with negative-pressure wound closure provides for successful eradication of the infection, reconstruction of the bone defect, and soft-tissue closure. A single-stage surgical treatment is feasible, without any complications.

  12. Comparison of the bone regeneration ability between stem cells from human exfoliated deciduous teeth, human dental pulp stem cells and human bone marrow mesenchymal stem cells.

    PubMed

    Nakajima, Kengo; Kunimatsu, Ryo; Ando, Kazuyo; Ando, Toshinori; Hayashi, Yoko; Kihara, Takuya; Hiraki, Tomoka; Tsuka, Yuji; Abe, Takaharu; Kaku, Masato; Nikawa, Hiroki; Takata, Takashi; Tanne, Kazuo; Tanimoto, Kotaro

    2018-03-11

    Cleft lip and palate is the most common congenital anomaly in the orofacial region. Autogenous iliac bone graft, in general, has been employed for closing the bone defect at the alveolar cleft. However, such iliac bone graft provides patients with substantial surgical and psychological invasions. Consequently, development of a less invasive method has been highly anticipated. Stem cells from human exfoliated deciduous teeth (SHED) are a major candidate for playing a significant role in tissue engineering and regenerative medicine. The aim of this study was to elucidate the nature of bone regeneration by SHED as compared to that of human dental pulp stem cells (hDPSCs) and bone marrow mesenchymal stem cells (hBMSCs). The stems cells derived from pulp tissues and bone marrow were transplanted with a polylactic-coglycolic acid barrier membrane as a scaffold, for use in bone regeneration in an artificial bone defect of 4 mm in diameter in the calvaria of immunodeficient mice. Three-dimensional analysis using micro CT and histological evaluation were performed. Degree of bone regeneration with SHED relative to the bone defect was almost equivalent to that with hDPSCs and hBMSCs 12 weeks after transplantation. The ratio of new bone formation relative to the pre-created bone defect was not significantly different among groups with SHED, hDPSCs and hBMSCs. In addition, as a result of histological evaluation, SHED produced the largest osteoid and widely distributed collagen fibers compared to hDPSCs and hBMSCs groups. Thus, SHED transplantation exerted bone regeneration ability sufficient for the repair of bone defect. The present study has demonstrated that SHED is one of the best candidate as a cell source for the reconstruction of alveolar cleft due to the bone regeneration ability with less surgical invasion. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Modified animal model and computer-assisted approach for dentoalveolar distraction osteogenesis to reconstruct unilateral maxillectomy defect.

    PubMed

    Feng, Zhihong; Zhao, Jinlong; Zhou, Libin; Dong, Yan; Zhao, Yimin

    2009-10-01

    The purpose of this report is to show the establishment of an animal model with a unilateral maxilla defect, application of virtual reality and rapid prototyping in the surgical planning for dentoalveolar distraction osteogenesis (DO). Two adult dogs were used to develop an animal model with a unilateral maxillary defect. The 3-dimensional model of the canine craniofacial skeleton was reconstructed with computed tomography data using the software Mimics, version 12.0 (Materialise Group, Leuven, Belgium). A virtual individual distractor was designed and transferred onto the model with the defect, and the osteotomies and distraction processes were simulated. A precise casting technique and numeric control technology were applied to produce the titanium distraction device, which was installed on the physical model with the defect, which was generated using Selective Laser Sintering technology, and the in vitro simulation of osteotomies and DO was done. The 2 dogs survived the operation and were lively. The osteotomies and distraction process were simulated successfully whether on the virtual or the physical model. The bone transport could be distracted to the desired position both in the virtual environment and on the physical model. The novel method to develop an animal model with a unilateral maxillary defect was feasible, and the animal model was suitable to develop the reconstruction method for unilateral maxillary defect cases with dentoalveolar DO. Computer-assisted surgical planning and simulation improved the reliability of the maxillofacial surgery, especially for the complex cases. The novel idea to reconstruct the unilateral maxillary defect with dentoalveolar DO was proved through the model experiment.

  14. Neurosurgical robotic arm drilling navigation system.

    PubMed

    Lin, Chung-Chih; Lin, Hsin-Cheng; Lee, Wen-Yo; Lee, Shih-Tseng; Wu, Chieh-Tsai

    2017-09-01

    The aim of this work was to develop a neurosurgical robotic arm drilling navigation system that provides assistance throughout the complete bone drilling process. The system comprised neurosurgical robotic arm navigation combining robotic and surgical navigation, 3D medical imaging based surgical planning that could identify lesion location and plan the surgical path on 3D images, and automatic bone drilling control that would stop drilling when the bone was to be drilled-through. Three kinds of experiment were designed. The average positioning error deduced from 3D images of the robotic arm was 0.502 ± 0.069 mm. The correlation between automatically and manually planned paths was 0.975. The average distance error between automatically planned paths and risky zones was 0.279 ± 0.401 mm. The drilling auto-stopping algorithm had 0.00% unstopped cases (26.32% in control group 1) and 70.53% non-drilled-through cases (8.42% and 4.21% in control groups 1 and 2). The system may be useful for neurosurgical robotic arm drilling navigation. Copyright © 2016 John Wiley & Sons, Ltd.

  15. Reconstruction of chest wall using a two-layer prolene mesh and bone cement sandwich.

    PubMed

    Aghajanzadeh, Manouchehr; Alavi, Ali; Aghajanzadeh, Gilda; Ebrahimi, Hannan; Jahromi, Sina Khajeh; Massahnia, Sara

    2015-02-01

    Wide surgical resection is the most effective treatment for the vast majority of chest wall tumors. This study evaluated the clinical success of chest wall reconstruction using a Prolene mesh and bone cement prosthetic sandwich. The records of all patients undergoing chest wall resection and reconstruction were reviewed. Surgical indications, the location and size of the chest wall defect, diaphragm resection, pulmonary performance, postoperative complications, and survival of each patient were recorded. From 1998 to 2008, 43 patients (27 male, 16 female; mean age of 48 years) underwent surgery in our department to treat malignant chest wall tumors: chondrosarcoma (23), osteosarcoma (8), spindle cell sarcoma (6), Ewing's sarcoma (2), and others (4). Nine sternectomies and 34 antero-lateral and postero-lateral chest wall resections were performed. Postoperatively, nine patients experienced respiratory complications, and one patient died because of respiratory failure. The overall 4-year survival rate was 60 %. Chest wall reconstruction using a Prolene mesh and bone cement prosthetic sandwich is a safe and effective surgical procedure for major chest wall defects.

  16. Piezosurgery: A new and safe technique for distraction osteogenesis in Pierre Robin sequence review of the literature and case report

    PubMed Central

    Galié, Manlio; Candotto, Valentina; Elia, Giovanni; Clauser, Luigi C.

    2014-01-01

    Introduction Pierre Robin sequence (PRS) is characterized by microgenia and retrognathia. Cleft palate and glossoptosis are frequently associated with airway obstruction and difficulty in swallowing. Distraction osteogenesis with micro-distractors has recently been considered as a surgical option during the neonatal age. Case presentation A 6-week-old female with PRS underwent mandibular lengthening in neonatal age. Mandibular osteotomies were performed with the piezoelectric scalpel. Discussion Piezosurgery represents an innovative technique as it offers the maxillofacial surgeon the opportunity to make precise bone cuts without damaging the soft tissue, minimizing the invasiveness of the surgical procedure, and the opportunity of working in a field which is almost totally blood free. Conclusion The use of a piezoelectric device to perform this kind of surgery provides clinical and surgical results which would be difficult with traditional instruments, not only for the patient’s benefit but also for the surgeon’s. Preservation of the original bony structure, especially of the cancellous bone, will benefit the bone healing process due to its high estrogenic potential. PMID:25555147

  17. Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process.

    PubMed

    Shahidi, Shoaleh; Zamiri, Barbad; Abolvardi, Masoud; Akhlaghian, Marzieh; Paknahad, Maryam

    2018-06-01

    Accurate measurement of the available bone height is an essential step in the pre-surgical phase of dental implantation. Panoramic radiography is a unique technique in the pre-surgical phase of dental implantations because of its low cost, relatively low-dose, and availability. This article aimed to assess the reliability of dental panoramic radiographs in the accurate measurement of the vertical bone height with respect to the horizontal location of the alveolar crest. 132 cone-beam computed tomography (CBCT) of the edentulous mandibular molar area and dental panoramic radiograph of 508 patients were selected. Exclusion criteria were bone abnormalities and detectable ideal information on each modality. The alveolar ridge morphology was categorized into 7 types according to the relative horizontal location of the alveolar crest to the mandibular canal based on CBCT findings. The available bone height (ABH) was defined as the distance between the upper border of the mandibular canal and alveolar crest. One oral radiologist and one oral surgeon measured the available bone height twice on each modality with a 7-dayinterval. We found a significant correlation between dental panoramic radiographs and cone-beam computed tomography values (ICC=0.992, p < 0.001). A positive correlation between the horizontal distance of the alveolar crest to the mandibular canal and measured differences between two radiographic modalities had been found (r=0.755, p < 0.001). For each single unit of increase in the horizontal distance of the alveolar crest to the mandibular canal, dental panoramic radiographs showed 0.87 unit of overestimation ( p < 0.001). Dental panoramic radiographs can be employed safely in the pre-surgical phase of dental implantation in posterior alveolus of mandible, especially in routine and simple cases.

  18. Persistent non-union of the humeral shaft treated by plating and autologous bone grafting.

    PubMed

    Pollon, Tristan; Reina, Nicolas; Delclaux, Stéphanie; Bonnevialle, Paul; Mansat, Pierre; Bonnevialle, Nicolas

    2017-02-01

    Surgical treatment of persistent non-union of the humeral shaft is a complex situation because of the risk of failure and surgery-related complications. The primary objective of this study was to evaluate clinical and radiological results of a continuous series of persistent non-union treated with plating and bone grafting. The secondary objective was to expose factors contributing to the failure of prior bone union attempts. Sixteen patients (average age of 52 years) were treated for persistent non-union of the humeral shaft in our department; six of these patients had predisposing comorbidities or addictions. The persistent non-union was treated by plating with autologous bone graft from the iliac crest in a single-stage procedure in 12 cases and a two-stage procedure in three cases; one case was treated with plating and vascularized fibula graft. At a minimum follow-up of 12 months (average 78 months), four (25 %) failed to heal. The 12 other patients had bone union after an average of eight months. The average QuickDASH score was 48 points (18-72). A retrospective analysis of the prior attempts to treat the non-union revealed three cases of unstable fixation, four cases with no osteogenic supply and seven cases of positive microbiological cultures at the non-union site. Plating and autologous bone grafting resulted in union in only 75 % of persistent non-union of the humeral shaft. The persistent nature of the humeral shaft non-union could be attributed to deviating from validated rules for surgical treatment and/or the presence of a surgical site infection.

  19. Simulating Bone Loss in Microgravity Using Mathematical Formulations of Bone Remodeling

    NASA Technical Reports Server (NTRS)

    Pennline, James A.

    2009-01-01

    Most mathematical models of bone remodeling are used to simulate a specific bone disease, by disrupting the steady state or balance in the normal remodeling process, and to simulate a therapeutic strategy. In this work, the ability of a mathematical model of bone remodeling to simulate bone loss as a function of time under the conditions of microgravity is investigated. The model is formed by combining a previously developed set of biochemical, cellular dynamics, and mechanical stimulus equations in the literature with two newly proposed equations; one governing the rate of change of the area of cortical bone tissue in a cross section of a cylindrical section of bone and one governing the rate of change of calcium in the bone fluid. The mechanical stimulus comes from a simple model of stress due to a compressive force on a cylindrical section of bone which can be reduced to zero to mimic the effects of skeletal unloading in microgravity. The complete set of equations formed is a system of first order ordinary differential equations. The results of selected simulations are displayed and discussed. Limitations and deficiencies of the model are also discussed as well as suggestions for further research.

  20. Evaluation of trabecular bone patterns on dental radiographic images: influence of cortical bone

    NASA Astrophysics Data System (ADS)

    Amouriq, Yves; Evenou, Pierre; Arlicot, Aurore; Normand, Nicolas; Layrolle, Pierre; Weiss, Pierre; Guédon, Jean-Pierre

    2010-03-01

    For some authors trabecular bone is highly visible in intraoral radiographs. For other authors, the observed intrabony trabecular pattern is a representation of only the endosteal surface of cortical bone, not of intermedullary striae. The purpose of this preliminary study was to investigate the true anatomical structures that are visible in routine dental radiographs and classically denoted trabecular bone. This is a major point for bone texture analysis on radiographs. Computed radiography (CR) images of dog mandible section in molar region were compared with simulations calculated from high-resolution micro-CT volumes. Calculated simulations were obtained using the Mojette Transform. By digitally editing the CT volume, the simulations were separated into trabecular and cortical components into a region of interest. Different images were compared and correlated, some bone micro-architecture parameters calculated. A high correlation was found between computed radiographs and calculated simulations from micro-CT. The Mojette transform was successful to obtain high quality images. Cortical bone did not contribute to change in a major way simulated images. These first results imply that intrabony trabecular pattern observed on radiographs can not only be a representation of the cortical bone endosteal surface and that trabecular bone is highly visible in intraoral radiographs.

  1. Preoperative surgical rehearsal using cadaveric fresh tissue surgical simulation increases resident operative confidence.

    PubMed

    Weber, Erin L; Leland, Hyuma A; Azadgoli, Beina; Minneti, Michael; Carey, Joseph N

    2017-08-01

    Rehearsal is an essential part of mastering any technical skill. The efficacy of surgical rehearsal is currently limited by low fidelity simulation models. Fresh cadaver models, however, offer maximal surgical simulation. We hypothesize that preoperative surgical rehearsal using fresh tissue surgical simulation will improve resident confidence and serve as an important adjunct to current training methods. Preoperative rehearsal of surgical procedures was performed by plastic surgery residents using fresh cadavers in a simulated operative environment. Rehearsal was designed to mimic the clinical operation, complete with a surgical technician to assist. A retrospective, web-based survey was used to assess resident perception of pre- and post-procedure confidence, preparation, technique, speed, safety, and anatomical knowledge on a 5-point scale (1= not confident, 5= very confident). Twenty-six rehearsals were performed by 9 residents (PGY 1-7) an average of 4.7±2.1 days prior to performance of the scheduled operation. Surveys demonstrated a median pre-simulation confidence score of 2 and a post-rehearsal score of 4 (P<0.01). The perceived improvement in confidence and performance was greatest when simulation was performed within 3 days of the scheduled case. All residents felt that cadaveric simulation was better than standard preparation methods of self-directed reading or discussion with other surgeons. All residents believed that their technique, speed, safety, and anatomical knowledge improved as a result of simulation. Fresh tissue-based preoperative surgical rehearsal was effectively implemented in the residency program. Resident confidence and perception of technique improved. Survey results suggest that cadaveric simulation is beneficial for all levels of residents. We believe that implementation of preoperative surgical rehearsal is an effective adjunct to surgical training at all skill levels in the current environment of decreased work hours.

  2. Deproteinized Bovine Bone Mineral or Autologous Bone at Dehiscence Type Defects at Implants Installed Immediately into Extraction Sockets: An Experimental Study in Dogs.

    PubMed

    Pereira, Flavia Priscila; De Santis, Enzo; Hochuli-Vieira, Eduardo; de Souza Faco, Eduardo F; Pantani, Fabio; Salata, Luiz A; Botticelli, Daniele

    2016-06-01

    The aim of this study was to evaluate bone regeneration at surgically created dehiscence buccal defects at implants placed immediately into extraction sockets (IPIES) of small dimensions filled with autogenous bone or deproteinized bovine bone mineral (DBBM) associated with a collagen membrane. Eight Labrador dogs were used and implants were placed immediately into the extraction sockets of the second premolar. The buccal wall was subsequently removed to create a standardized defect, 4 mm wide coronally, 2 mm wide apically, and 6 mm high. Autogenous bone particles (AB) or DBBM granules were used to fill the defects. All surgical sites were subsequently covered by a resorbable collagen membrane and a non-submerged healing was allowed. After 4 months, the animals were euthanized and bone blocks harvested and processed for histomorphometric analysis. The bony crest at the buccal aspect (C) was located 2.3 ± 0.8 mm and 1.7 ± 0.7 mm apically to the implant shoulder (IS) at the AB and DBBM sites, respectively. The coronal levels of osseointegration at the buccal aspect (B) were located 2.7 ± 0.7 mm and 2.2 ± 1.0 mm apically to IS at the AB and DBBM sites, respectively. At the AB sites, the peri-implant mucosa was located 4.3 ± 0.9 mm, 4.7 ± 0.9 mm, and 2.0 ± 1.6 mm coronally to C, B, and IS, respectively. The corresponding values at the DBBM sites were 4.3 ± 0.6 mm, 4.8 ± 0.6 mm, and 2.5 ± 0.8 mm, respectively. No statistically significant differences were found. The treatment of surgically created buccal defects at IPIES sites using Bio-Oss® (Geistlich Biomaterials, Wolhusen, LU, Switzerland) or autogenous bone, concomitantly with a collagen membrane, engenders bone regeneration to a similar extent after 4 months of healing. © 2015 Wiley Periodicals, Inc.

  3. In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials.

    PubMed

    Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping

    2015-01-01

    To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair.

  4. In vivo biocompatibility of new nano-calcium-deficient hydroxyapatite/poly-amino acid complex biomaterials

    PubMed Central

    Dai, Zhenyu; Li, Yue; Lu, Weizhong; Jiang, Dianming; Li, Hong; Yan, Yonggang; Lv, Guoyu; Yang, Aiping

    2015-01-01

    Objective To evaluate the compatibility of novel nano-calcium-deficient hydroxyapatite/poly-amino acid (n-CDHA/PAA) complex biomaterials with muscle and bone tissue in an in vivo model. Methods Thirty-two New Zealand white rabbits were used in this study. Biomaterials were surgically implanted into each rabbit in the back erector spinae and in tibia with induced defect. Polyethylene was implanted into rabbits in the control group and n-CDHA/PAA into those of the experimental group. Animals were examined at four different points in time: 2 weeks, 4 weeks, 12 weeks, and 24 weeks after surgery. They were euthanized after embolization. Back erector spinae muscles with the surgical implants were examined after hematoxylin and eosin (HE) staining at these points in time. Tibia bones with the surgical implants were examined by X-ray and scanning electron microscopy (SEM) at these points in time to evaluate the interface of the bone with the implanted biomaterials. Bone tissues were sectioned and subjected to HE, Masson, and toluidine blue staining. Results HE staining of back erector spinae muscles at 4 weeks, 12 weeks, and 24 weeks after implantation of either n-CDHA/PAA or polyethylene showed disappearance of inflammation and normal arrangement in the peripheral tissue of implant biomaterials; no abnormal staining was observed. At 2 weeks after implantation, X-ray imaging of bone tissue samples in both experimental and control groups showed that the peripheral tissues of the implanted biomaterials were continuous and lacked bone osteolysis, absorption, necrosis, or osteomyelitis. The connection between implanted biomaterials and bone tissue was tight. The results of HE, Masson, toluidine blue staining and SEM confirmed that the implanted biomaterials were closely connected to the bone defect and that no rejection had taken place. The n-CDHA/PAA biomaterials induced differentiation of a large number of chondrocytes. New bone trabecula began to form at 4 weeks after implanting n-CDHA/PAA biomaterials, and lamellar bone gradually formed at 12 weeks and 24 weeks after implantation. Routine blood and kidney function tests showed no significant changes at 2 weeks and 24 weeks after implantation of both biomaterials. Conclusion n-CDHA/PAA composites showed good compatibility in in vivo model. In this study, n-CDHA/PAA were found to be safe, nontoxic, and biologically active in bone repair. PMID:26504382

  5. Fixation of a split fracture of the lateral tibial plateau with a locking screw plate instead of cannulated screws would allow early weight bearing: a computational exploration.

    PubMed

    Carrera, Ion; Gelber, Pablo Eduardo; Chary, Gaetan; González-Ballester, Miguel A; Monllau, Juan Carlos; Noailly, Jerome

    2016-10-01

    To assess, with finite element (FE) calculations, whether immediate weight bearing would be possible after surgical stabilization either with cannulated screws or with a locking plate in a split fracture of the lateral tibial plateau (LTP). A split fracture of the LTP was recreated in a FE model of a human tibia. A three-dimensional FE model geometry of a human femur-tibia system was obtained from the VAKHUM project database, and was built from CT images from a subject with normal bone morphologies and normal alignment. The mesh of the tibia was reconverted into a geometry of NURBS surfaces. A split fracture of the lateral tibial plateau was reproduced by using geometrical data from patient radiographs. A locking screw plate (LP) and a cannulated screw (CS) systems were modelled to virtually reduce the fracture and 80 kg static body-weight was simulated. While the simulated body-weight led to clinically acceptable interfragmentary motion, possible traumatic bone shear stresses were predicted nearby the cannulated screws. With a maximum estimation of about 1.7 MPa maximum bone shear stresses, the Polyax system might ensure more reasonable safety margins. Split fractures of the LTP fixed either with locking screw plate or cannulated screws showed no clinically relevant IFM in a FE model. The locking screw plate showed higher mechanical stability than cannulated screw fixation. The locking screw plate might also allow full or at least partial weight bearing under static posture at time zero.

  6. Technology and medicine: the evolution of virtual reality simulation in laparoscopic training.

    PubMed

    Bashir, Gareth

    2010-01-01

    Virtual reality (VR) simulation for laparoscopic surgical training is now a reality. There is increasing evidence that the use of VR simulation is a powerful adjunct to traditional surgical apprenticeship in the current climate of reduced time spent in training. This article reviews the early evidence supporting the case for VR simulation training in laparoscopic surgery. A standard literature search was conducted using the following phrases--'virtual reality in surgical training', 'surgical training', 'laparoscopic training' and 'simulation in surgical training'. This article outlines the early evidence which supports the use of VR simulation in laparoscopic training and the need for further research into this new training technique.

  7. A Craniomaxillofacial Surgical Assistance Workstation for Enhanced Single-Stage Reconstruction Using Patient-Specific Implants.

    PubMed

    Murphy, Ryan J; Liacouras, Peter C; Grant, Gerald T; Wolfe, Kevin C; Armand, Mehran; Gordon, Chad R

    2016-11-01

    Craniomaxillofacial reconstruction with patient-specific, customized craniofacial implants (CCIs) is ideal for skeletal defects involving areas of aesthetic concern-the non-weight-bearing facial skeleton, temporal skull, and/or frontal-forehead region. Results to date are superior to a variety of "off-the-shelf" materials, but require a protocol computed tomography scan and preexisting defect for computer-assisted design/computer-assisted manufacturing of the CCI. The authors developed a craniomaxillofacial surgical assistance workstation to address these challenges and intraoperatively guide CCI modification for an unknown defect size/shape. First, the surgeon designed an oversized CCI based on his/her surgical plan. Intraoperatively, the surgeon resected the bone and digitized the resection using a navigation pointer. Next, a projector displayed the limits of the craniofacial bone defect onto the prefabricated, oversized CCI for the size modification process; the surgeon followed the projected trace to modify the implant. A cadaveric study compared the standard technique (n = 1) to the experimental technique (n = 5) using surgical time and implant fit. The technology reduced the time and effort needed to resize the oversized CCI by an order of magnitude as compared with the standard manual resizing process. Implant fit was consistently better for the computer-assisted case compared with the control by at least 30%, requiring only 5.17 minutes in the computer-assisted cases compared with 35 minutes for the control. This approach demonstrated improvement in surgical time and accuracy of CCI-based craniomaxillofacial reconstruction compared with previously reported methods. The craniomaxillofacial surgical assistance workstation will provide craniofacial surgeons a computer-assisted technology for effective and efficient single-stage reconstruction when exact craniofacial bone defect sizes are unknown.

  8. Surgical management of primary bone tumors of the spine: validation of an approach to enhance cure and reduce local recurrence.

    PubMed

    Fisher, Charles G; Saravanja, Davor D; Dvorak, Marcel F; Rampersaud, Y Raja; Clarkson, Paul W; Hurlbert, John; Fox, Richard; Zhang, Hongbin; Lewis, Stephen; Riaz, Salman; Ferguson, Peter C; Boyd, Michael C

    2011-05-01

    Multicenter ambispective cohort analysis. The purpose of this study is to determine whether applying Enneking's principles to surgical management of primary bone tumors of the spine significant decreases local recurrence and/or mortality. Oncologic management of primary tumors of spine has historically been inconsistent, controversial, and open to individual interpretation. A multicenter ambispective cohort analysis from 4 tertiary care spine referral centers was done. Patients were analyzed in 2 cohorts, "Enneking Appropriate" (EA), surgical margin as recommended by Enneking, and "Enneking Inappropriate" (EI), surgical margin not recommended by Enneking. Benign tumors were not included in mortality analysis. Two cohorts represented an analytic dataset with 147 patients, 86 male, average age 46 years (range: 10-83). Median follow-up was 4 (2-7) years in the EA and 6 (5.5-15.5) years in the EI. Seventy-one patients suffered at least 1 local recurrence during the study, 57 of 77 in the EI group and 14 of 70 in the EA group. EI surgical approach caused higher risk of first local recurrence (P < 0.0001). There were 48 deaths in total; 29 in the EI group and 19 in the EA. There was a strong correlation between the first local recurrence and mortality with an odds ratio of 4.69, (P < 0.0001). EI surgical approach resulted in a higher risk of mortality with a hazard ratio of 3.10, (P = 0.0485) compared to EA approach. Surgery results in a significant reduction in local recurrence when primary bone tumors of the spine are resected with EA margins. Local recurrence has a high concordance with mortality in resection of these tumors. A significant decrease in mortality occurs when EA surgery is used.

  9. Aneurysmal bone cyst of the scapula. A case report.

    PubMed

    Megas, Panagiotis; Papathanassiou, Zafiria G; Kasimatis, George; Papachristou, Dionysios J

    2009-10-01

    Aneurysmal bone cyst (ABC) is an uncommon, benign but locally destructive bone lesion of unknown origin. Differential diagnosis can be challenging as it shares common radiological and pathological features with other benign and malignant bone lesions. The degree of diagnostic difficulty grows even more when an unusual location has to be taken into account. We report a rare and challenging case of a large primary ABC located at the scapula of a young male, who was surgically treated with subtotal removal of the scapula.

  10. Optimal Treatment of Malignant Long Bone Fracture: Influence of Method of Repair and External Beam Irradiation on the Pathway and Efficacy of Fracture Healing

    DTIC Science & Technology

    2014-10-01

    Long Bone Fracture: Influence of Method of Repair and External Beam Irradiation on the Pathway and Efficacy of Fracture Healing 5a. CONTRACT NUMBER...in the fifth quarter of the award. 15. SUBJECT TERMS Fracture healing , bone healing , endochondral ossification, intramembranous ossification...of radiation on the two pathways of bone healing and propose an optimal method of surgical fracture repair for managing malignant osteoporotic

  11. Heterotopic bone formation in the musculus latissimus dorsi of sheep using β-tricalcium phosphate scaffolds: evaluation of an extended prefabrication time on bone formation and matrix degeneration.

    PubMed

    Spalthoff, S; Jehn, P; Zimmerer, R; Möllmann, U; Gellrich, N-C; Kokemueller, H

    2015-06-01

    We previously generated viable heterotopic bone in living animals and found that 3 months of intrinsic vascularization improved bone formation and matrix degeneration. In this study, we varied the pre-vascularization time to determine its effects on the kinetics of bone formation and ceramic degradation. Two 25-mm-long cylindrical β-tricalcium phosphate scaffolds were filled intraoperatively with autogenous iliac crest bone marrow and implanted in the latissimus dorsi muscle in six sheep. To examine the effect of axial perfusion, one scaffold was surgically implanted with (group C) or without (group D) a central vascular bundle. All animals were sacrificed 6 months postoperatively and histomorphometric measurements were compared to previous results. All implanted scaffolds exhibited ectopic bone growth. However, bone growth was not significantly different between the 3-month (group A, 0.191±0.097 vs. group C, 0.237±0.075; P=0.345) and 6-month (group B, 0.303±0.105 vs. group D, 0.365±0.258; P=0.549) pre-vascularization durations, regardless of vessel supply; early differences between surgically and extrinsically vascularized constructs disappeared after 6 months. Here, we describe a reliable procedure for generating ectopic bone in vivo. A 3-month pre-vascularization duration appears sufficient and ceramic degradation proceeds in accordance with bone generation, supporting the hypothesis of cell-mediated resorption. Copyright © 2014 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Immediate titanium mesh cranioplasty for treatment of post-craniotomy infections

    PubMed Central

    Wind, Joshua J.; Ohaegbulam, Chima; Iwamoto, Fabio M.; Black, Peter McL.; Park, John K.

    2011-01-01

    OBJECTIVE Post craniotomy infections have generally been treated by debridement of infected tissues, disposal of the bone flap, and delayed cranioplasty several months later to repair the resulting skull defect. Debridement followed by retention of the bone flap has also been advocated. Here we propose an alternative operative strategy for the treatment of post craniotomy infections. METHODS Two patients presenting with clinical and radiographic signs and symptoms of post craniotomy infections were treated by debridement, bone flap disposal, and immediate titanium mesh cranioplasty. The patients were subsequently administered antibiotics and their clinical courses were followed. RESULTS The patients treated in this fashion did not have recurrence of their infections during three-year follow-up periods. CONCLUSIONS Surgical debridement, bone flap disposal and immediate titanium mesh cranioplasty may be a suitable option for the treatment of post craniotomy infections. This treatment strategy facilitates the eradication of infectious sources and obviates the risks and costs associated with a second surgical procedure. PMID:22120410

  13. [Epoxide acrylate maleic resin and hydroxyapatite composite material as a bone graft substitute in surgical correction of orbital reconstruction].

    PubMed

    Mu, X; Dong, J; Wang, W

    1995-11-01

    This paper illustrates the results of surgical correction in 11 cases with orbital deformities such as periorbital deficiency after orbitotomy for retinoblastoma and orbital malposition after facial trauma. EH composite material, mixture of hydroxyapatite and epoxide acrylate maleic resin in constant proportion, was used as a good bone graft substitute in all 11 cases. This material was easier to be molded during surgery, safe to human body, had no toxic effects, no irritation and no implant-related complications. The early results obtained in these patients are encouraging.

  14. All Internal Segmental Bone Transport and Optional Lengthening With a Newly Developed Universal Cylinder-Kombi-Tube Module for Motorized Nails-Description of a Surgical Technique.

    PubMed

    Krettek, Christian; El Naga, Ashraf

    2017-10-01

    Segmental transport is an effective method of treatment for segmental defects, but the need for external fixation during the transport phase is a disadvantage. To avoid external fixation, we have developed a Cylinder-Kombi-Tube Segmental Transport (CKTST) module for combination with a commercially available motorized lengthening nail. This CKTST module allows for an all-internal segmental bone transport and also allows for optional lengthening if needed. The concept and surgical technique of CKTST are described and illustrated with a clinical case.

  15. [Remodeling simulation of human femur under bed rest and spaceflight circumstances based on three dimensional finite element analysis].

    PubMed

    Yang, Wenting; Wang, Dongmei; Lei, Zhoujixin; Wang, Chunhui; Chen, Shanguang

    2017-12-01

    Astronauts who are exposed to weightless environment in long-term spaceflight might encounter bone density and mass loss for the mechanical stimulus is smaller than normal value. This study built a three dimensional model of human femur to simulate the remodeling process of human femur during bed rest experiment based on finite element analysis (FEA). The remodeling parameters of this finite element model was validated after comparing experimental and numerical results. Then, the remodeling process of human femur in weightless environment was simulated, and the remodeling function of time was derived. The loading magnitude and loading cycle on human femur during weightless environment were increased to simulate the exercise against bone loss. Simulation results showed that increasing loading magnitude is more effective in diminishing bone loss than increasing loading cycles, which demonstrated that exercise of certain intensity could help resist bone loss during long-term spaceflight. At the end, this study simulated the bone recovery process after spaceflight. It was found that the bone absorption rate is larger than bone formation rate. We advise that astronauts should take exercise during spaceflight to resist bone loss.

  16. Leaders by example: Best practices and advice on establishing a state-of-the art surgical simulation center that optimizes available resources.

    PubMed

    Gardner, A K; Ritter, E M; Dunkin, B J; Smink, D S; Lau, J N; Paige, J T; Phitayakorn, R; Acton, R D; Stefanidis, D; Gee, D W

    2018-02-01

    The role of simulation-based education continues to expand exponentially. To excel in this environment as a surgical simulation leader requires unique knowledge, skills, and abilities that are different from those used in traditional clinically-based education. Leaders in surgical simulation were invited to participate as discussants in a pre-conference course offered by the Association for Surgical Education. Highlights from their discussions were recorded. Recommendations were provided on topics such as building a simulation team, preparing for accreditation requirements, what to ask for during early stages of development, identifying tools and resources needed to meet educational goals, expanding surgical simulation programming, and building educational curricula. These recommendations provide new leaders in simulation with a unique combination of up-to-date best practices in simulation-based education, as well as valuable advice gained from lessons learned from the personal experiences of national leaders in the field of surgical simulation and education. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Surgical Treatments of Tumor-Induced Osteomalacia Lesions in Long Bones: Seventeen Cases with More Than One Year of Follow-up.

    PubMed

    Wang, Hai; Zhong, Dingrong; Liu, Yong; Jiang, Yan; Qiu, Guixing; Weng, Xisheng; Xing, Xiaoping; Li, Mei; Meng, Xunwu; Li, Fang; Zhu, Zhaohui; Yu, Wei; Xia, Weibo; Jin, Jin

    2015-07-01

    Tumor-induced osteomalacia is a rare and fascinating paraneoplastic syndrome usually caused by a small, benign phosphaturic mesenchymal tumor. Most tumors are treated surgically, but we are unaware of any reports that compare the results of curettage and segmental resection for lesions in long bones. Seventeen patients (ten male and seven female) with tumor-induced osteomalacia lesions in long bones, who underwent surgical treatment from December 2004 to August 2013 in our hospital, were included in this retrospective study. The mean follow-up (and standard deviation) was 35 ± 27 months (range, twelve to 116 months). The characteristics of the tumor and the effects of different surgical treatments (curettage compared with segmental resection) were evaluated. All patients showed typical clinical characteristics of tumor-induced osteomalacia, including elevated serum fibroblast growth factor-23 (FGF-23); 82% of tumors were in the epiphysis, and 82% grew eccentrically. The mean maximum diameter of the tumors was 2.4 ± 2.0 cm. The complete resection rates were similar for curettage (67%) and segmental resection (80%). However, the recurrence rate after curettage (50%) was higher than that after segmental resection (0%). The complete resection rate for secondary segmental resection (75%) was not different from that for primary segmental resection (83%). All of our cases of tumor-induced osteomalacia were caused by phosphaturic mesenchymal tumors. After successful removal of tumors, serum FGF-23 returned to normal within twenty-four hours and serum phosphorus levels returned to normal at a mean of 6.5 ± 3.5 days. Most lesions in long bones are located in the epiphysis, so curettage is first suggested to maintain joint function. If curettage is incomplete or there is a recurrence, secondary segmental resection should be considered curative. Changes of serum FGF-23 and phosphorus levels before and after the operation may be of prognostic help. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  18. Soft-tissue grafting for peri-implantitis-a treatment option in case of unsuitable skeletal basic morphology of the alveolar bone and lack of keratinized mucosa: a retrospective clinical cohort study.

    PubMed

    Stiller, Michael; Mengel, Rainer; Becher, Sebastian; Brinkmann, Bernhard; Peleska, Barbara; Kluk, Esther

    2015-12-01

    This retrospective study evaluated soft-tissue grafting as a surgical treatment option for peri-implantitis in case of unsuitable basic skeletal morphology of the alveolar bone and lack of keratinized mucosa. Twenty-eight patients (21 females, 7 males, at a mean age 59.4 years) were included with a total of 54 implants. All implants showed peri-implantitis and attached keratinized buccal mucosa of ≤2 mm. A surgical procedure of soft-tissue grafting (STG) was made by inserting an inlay and inlay-onlay transplant. Clinical investigations were made prior to the STG (baseline) and after 9-180 months (Ø 43 months) including the following parameters: soft-tissue biotype, skeletal basic morphology of the alveolar bone, width of the peri-implant keratinized mucosa (KM), mobility of the KM, pocket probing depth (PPD), and bleeding on probing (BOP). Nearly all patients showed a thin soft-tissue biotype. The analysis of the skeletal basic morphology of the alveolar bone revealed a narrow apical base in 18 patients, middle base in 7 patients, and broad base in 3 patients. Width of the KM increased significantly (p < 0.01) from 0.4 ± 0,5 mm to 4.3 ± 1.5 mm after STG and PPD was significantly (p < 0,01) reduced from 6.3 ± 2,3 mm to 4.1 ± 1.9 mm. A significant reduction (p < 0.01) in BOP was recorded. All patients reported a clinical improvement of the inflammatory symptoms at follow-up. The results of this study showed that the STG can be applied successfully as a surgical treatment of peri-implantitis. It remains unclear whether soft-tissue biotype or the skeletal basic morphology of the alveolar bone affects the outcome of this surgical treatment.

  19. Actual and Simulated Weightlessness Inhibit Osteogenesis in Long Bone Metaphysis by Different Mechanisms

    NASA Technical Reports Server (NTRS)

    Roberts, W. E.

    1985-01-01

    Weightlessness and simulated weightlessness inhibit the rate of periosteal bone formation in long bones. Formation of preosteoblasts is suppressed in periodontal ligament (PDL) of maxillary molars, which suggests a generalized block in osteoblast histogenesis. Growth in length of long bones is decreased by simulated weightlessness, but there are no reliable data on the influence of actual weightlessness on metaphyseal growth. The nuclear size assay for assessing relative numbers of osteoblast precursor cells was utilized in the primary spongiosa of growing long bones subjected to actual and simulated weightlessness. It is found that: (1) Actual weightlessness decreases total number of osteogenic cells and inhibits differentiation of osteoblast precursor cells, (2) Simulated weightlessness suppresses only osteoblast differentation; and (3) The nuclear morphometric assay is an effective means of assessing osteogenic activity in the growing metaphysis or long bones.

  20. Simulation in surgery: a review.

    PubMed

    Tan, Shaun Shi Yan; Sarker, Sudip K

    2011-05-01

    The ability to acquire surgical skills requires consistent practice, and evidence suggests that many of these technical skills can be learnt away from the operating theatre. The aim of this review article is to discuss the importance of surgical simulation today and its various types, exploring the effectiveness of simulation in the clinical setting and its challenges for the future. Surgical simulation offers the opportunity for trainees to practise their surgical skills prior to entering the operating theatre, allowing detailed feedback and objective assessment of their performance. This enables better patient safety and standards of care. Surgical simulators can be divided into organic or inorganic simulators. Organic simulators, consisting of live animal and fresh human cadaver models, are considered to be of high-fidelity. Inorganic simulators comprise virtual reality simulators and synthetic bench models. Current evidence suggests that skills acquired through training with simulators, positively transfers to the clinical setting and improves operative outcome. The major challenge for the future revolves around understanding the value of this new technology and developing an educational curriculum that can incorporate surgical simulators.

  1. Engineered, axially-vascularized osteogenic grafts from human adipose-derived cells to treat avascular necrosis of bone in a rat model.

    PubMed

    Ismail, Tarek; Osinga, Rik; Todorov, Atanas; Haumer, Alexander; Tchang, Laurent A; Epple, Christian; Allafi, Nima; Menzi, Nadia; Largo, René D; Kaempfen, Alexandre; Martin, Ivan; Schaefer, Dirk J; Scherberich, Arnaud

    2017-11-01

    Avascular necrosis of bone (AVN) leads to sclerosis and collapse of bone and joints. The standard of care, vascularized bone grafts, is limited by donor site morbidity and restricted availability. The aim of this study was to generate and test engineered, axially vascularized SVF cells-based bone substitutes in a rat model of AVN. SVF cells were isolated from lipoaspirates and cultured onto porous hydroxyapatite scaffolds within a perfusion-based bioreactor system for 5days. The resulting constructs were inserted into devitalized bone cylinders mimicking AVN-affected bone. A ligated vascular bundle was inserted upon subcutaneous implantation of constructs in nude rats. After 1 and 8weeks in vivo, bone formation and vascularization were analyzed. Newly-formed bone was found in 80% of SVF-seeded scaffolds after 8weeks but not in unseeded controls. Human ALU+cells in the bone structures evidenced a direct contribution of SVF cells to bone formation. A higher density of regenerative, M2 macrophages was observed in SVF-seeded constructs. In both experimental groups, devitalized bone was revitalized by vascularized tissue after 8 weeks. SVF cells-based osteogenic constructs revitalized fully necrotic bone in a challenging AVN rat model of clinically-relevant size. SVF cells contributed to accelerated initial vascularization, to bone formation and to recruitment of pro-regenerative endogenous cells. Avascular necrosis (AVN) of bone often requires surgical treatment with autologous bone grafts, which is surgically demanding and restricted by significant donor site morbidity and limited availability. This paper describes a de novo engineered axially-vascularized bone graft substitute and tests the potential to revitalize dead bone and provide efficient new bone formation in a rat model. The engineering of an osteogenic/vasculogenic construct of clinically-relevant size with stromal vascular fraction of human adipose, combined to an arteriovenous bundle is described. This construct revitalized and generated new bone tissue. This successful approach proposes a novel paradigm in the treatment of AVN, in which an engineered, vascularized osteogenic graft would be used as a germ to revitalize large volumes of necrotic bone. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  2. Long-term effects of placing one or two cages in instrumented posterior lumbar interbody fusion.

    PubMed

    Zhang, Mingzheng; Pu, Fang; Xu, Liqiang; Zhang, Linlin; Yao, Jie; Li, Deyu; Wang, Yu; Fan, Yubo

    2016-06-01

    Posterior lumbar interbody fusion (PLIF) is an established surgical procedure for spine stabilization after the removal of an intervertebral disc. Researches have shown that inserting a single oblique cage has a similar immediate effect to coupled cages, and it has been proposed that single-cage PLIF is a useful alternative to traditional two-cage PLIF. However, it is not clear whether placing one or two cages represents the best choice for long-term fusion. The aim of this study is to examine how cage placement affects bone remodeling after PLIF surgery, and how this consequently impacts the long-term fusion process. A finite element model of a L3-L4 lumbar spine with PLIF was developed. The spinal segment was modeled with a partial laminectomy and a discectomy with partial facetectomy, and implanted with posterior pedicle screws. Two models were analyzed, one with coupled parallel cages and one with a single oblique cage. Adaptive bone remodeling was simulated according to Huiskes' criterion. The results showed that in the initial state prior to any bone remodeling, cage stress, cage subsidence and cage dislodgement in the single cage model were all greater than in the coupled cage model. In the final state after significant bone remodeling had taken place, these parameters had decreased in both models and the differences between the two models were reduced. Also, the single cage model demonstrated superior bone development in the bone graft when placed under a constant 400 N axial compressive load. Based on the long-term results, instrumented PLIF with a single cage could also be encouraged in clinical practice.

  3. Combustion Synthesis of Ca3(PO4)2 Net-Shape Surgical Implants

    NASA Technical Reports Server (NTRS)

    Ayers, Reed A.; Castillo, Martin; Gottoli, Guglielmo; Moore, John J.; Simske, Steven J.

    2006-01-01

    Self-propagating high-temperature combustion synthesis (SHS) is the basis of a method of making components of porous tricalcium phosphate [Ca3(PO4)2] and related compounds in net sizes and shapes for use as surgical implants that are compatible with bone. The SHS method offers advantages over prior methods of manufacturing Ca3(PO4)2-based surgical implants.

  4. [Tools for laparoscopic skill development - available trainers and simulators].

    PubMed

    Jaksa, László; Haidegger, Tamás; Galambos, Péter; Kiss, Rita

    2017-10-01

    The laparoscopic minimally invasive surgical technique is widely employed on a global scale. However, the efficient and ethical teaching of this technique requires equipment for surgical simulation. These educational devices are present on the market in the form of box trainers and virtual reality simulators, or some combination of those. In this article, we present a systematic overview of commercially available surgical simulators describing the most important features of each product. Our overview elaborates on box trainers and virtual reality simulators, and also touches on surgical robotics simulators, together with operating room workflow simulators, for the sake of completeness. Apart from presenting educational tools, we evaluated the literature of laparoscopic surgical education and simulation, to provide a complete picture of the unfolding trends in this field. Orv Hetil. 2017; 158(40): 1570-1576.

  5. The Outcomes of Nonelongating Intramedullary Fixation of the Lower Extremity for Pediatric Osteogenesis Imperfecta Patients: A Meta-analysis.

    PubMed

    Scollan, Joseph P; Jauregui, Julio J; Jacobsen, Christina M; Abzug, Joshua M

    Osteogenesis imperfecta is usually due to autosomal dominant mutations in type I collagen, leading to an increase in fractures and bone deformities, especially in the long bones of the lower extremities. The use of nonelongating intramedullary rods is an established surgical intervention to address such deformities. The rate of surgical complications has been reported to be as high as 187%, with revision rates as high as 90%, although exact global rates are unknown. As such, we sought to determine the published rates of (1) bone-related complications (including both fracture and deformity), (2) rod migration, and (3) complications that require reoperation. Following the Preferred Reporting Items for Systematic reviews and Meta-analyses (PRISMA) guidelines, 1295 studies were evaluated. After cross-referencing, and applying specific inclusion and exclusion criteria, a total of 7 studies were included in the final cohort. Data were extracted from the studies and analyzed. Random effect models determined the complication rates of intramedullary nonelongating rod procedures. A total of 359 primary nonelongating intramedullary rod procedures of tibiae and femurs, in patients with a mean age of 6 years (5.2 to 7.3 y), at a mean follow-up of 63 months (24 to 118 mo), were evaluated. 60% of the surgical procedures were on femurs, and 40% were on tibiae. The reoperation rate was 39.4%. The most common complication was rod migration, with a rate of 25.7%. The rate of bone-related complications was 19.5% including fractures (15.0%) and worsening bone deformity (4.3%). This is the first meta-analysis to identify the rates of complication and reoperation in lower limb intramedullary fixation for pediatric osteogenesis imperfecta patients. This study has shown that rod migration is the most common complication, followed by bone-related complications including fractures and deformity. Reoperations occur after nearly 40% of all procedures due to rod migration or bone-related complications. Level IV-retrospective meta-analysis.

  6. In vitro investigation of friction at the interface between bone and a surgical instrument.

    PubMed

    Parekh, Jugal; Shepherd, Duncan E T; Hukins, David W L; Hingley, Carl; Maffulli, Nicola

    2013-06-01

    This study investigated the friction between surgical instruments and bone to aid improvements to instrument design. The bases of orthopaedic surgical instruments are usually made of metal, especially stainless steel. Silicone elastomer was chosen as an alternate biocompatible material, which would be compliant on the bone surface when used as the base of an instrument. The coefficient of static friction was calculated at the bone/material interface in the presence of a synthetic solution that had a comparable viscosity to that of blood, to assess the friction provided by each base material. Three types of silicone elastomers with different hardnesses (Shore A hardness 23, 50 and 77) and three distinct stainless steel surfaces (obtained by spark erosion, sand blasting and surface grinding) were used to assess the friction provided by the materials on slippery bone. The bone specimens were taken from the flattest region of the femoral shaft of a bovine femur; the outer surfaces of the specimens were kept intact. In general, the stainless steel surfaces exhibited higher values of coefficient of static friction, compared to the silicone elastomer samples. The stainless steel surface finished by spark erosion (surface roughness Ra  = 8.9 ± 1.6 µm) had the highest coefficient value of 0.74 ± 0.04. The coefficient values for the silicone elastomer sample with the highest hardness (Dow Corning Silastic Q7-4780, Shore A hardness 77) was not significantly different to values provided by the stainless steel surface finished by sand blasting (surface roughness Ra  = 2.2 ± 0.1 µm) or surface grinding (surface roughness Ra  = 0.1 ± 0.0 µm). Based on the results of this study, it is concluded that silicone could be a potentially useful material for the design of bases of orthopaedic instruments that interface with bone.

  7. Total Face, Eyelids, Ears, Scalp, and Skeletal Subunit Transplant Cadaver Simulation: The Culmination of Aesthetic, Craniofacial, and Microsurgery Principles.

    PubMed

    Sosin, Michael; Ceradini, Daniel J; Hazen, Alexes; Levine, Jamie P; Staffenberg, David A; Saadeh, Pierre B; Flores, Roberto L; Brecht, Lawrence E; Bernstein, G Leslie; Rodriguez, Eduardo D

    2016-05-01

    The application of aesthetic, craniofacial, and microsurgical principles in the execution of face transplantation may improve outcomes. Optimal soft-tissue face transplantation can be achieved by incorporating subunit facial skeletal replacement and subsequent tissue resuspension. The purpose of this study was to establish a reconstructive solution for a full face and scalp burn and to evaluate outcome precision and consistency. Seven mock face transplants (14 cadavers) were completed in the span of 1 year. Components of the vascularized composite allograft included the eyelids, nose, lips, facial muscles, oral mucosa, total scalp, and ears; and skeletal subunits of the zygoma, nasal bone, and genial segment. Virtual surgical planning was used for osteotomy selection, and to evaluate postoperative precision of hard- and soft-tissue elements. Each transplant experience decreased each subsequent transplant surgical time. Prefabricated cutting guides facilitated a faster dissection of both donor and recipient tissue, requiring minimal alteration to the allograft for proper fixation of bony segments during inset. Regardless of donor-to-recipient size discrepancy, ample soft tissue was available to achieve tension-free allograft inset. Differences between virtual transplant simulation and posttransplant measurements were minimal or insignificant, supporting replicable and precise outcomes. This facial transplant model was designed to optimize reconstruction of extensive soft-tissue defects of the craniofacial region representative of electrical, thermal, and chemical burns, by incorporating skeletal subunits within the allograft. The implementation of aesthetic, craniofacial, and microsurgical principles and computer-assisted technology improves surgical precision, decreases operative time, and may optimize function.

  8. Surgical intervention of complex endo-perio lesions.

    PubMed

    Adcock, John E; Bright, David

    2007-08-01

    Complex endo-perio lesions are infrequent, but pose treatment dilemmas. The lesions are complex with bone loss involving adjacent teeth that are not part of the initial endodontic lesion. The aggressive bone loss is not clearly understood and apparently has some differences from the usual apical periodontitis.

  9. Development of a Drilling Simulator for Dental Implant Surgery.

    PubMed

    Kinoshita, Hideaki; Nagahata, Masahiro; Takano, Naoki; Takemoto, Shinji; Matsunaga, Satoru; Abe, Shinichi; Yoshinari, Masao; Kawada, Eiji

    2016-01-01

    The aim of this study was to develop and evaluate a dental implant surgery simulator that allows learners to experience the drilling forces necessary to perform an osteotomy in the posterior mandibular bone. The simulator contains a force-sensing device that receives input and counteracts this force, which is felt as resistance by the user. The device consists of an actuator, a load cell, and a control unit. A mandibular bone model was fabricated in which the predicted forces necessary to drill the cortical and trabecular bone were determined via micro CT image-based 3D finite element analysis. The simulator was evaluated by five dentists from the Department of Implantology at Tokyo Dental College. The ability of the evaluators to distinguish the drilling resistance through different regions of the mandibular bone was investigated. Of the five dentists, four sensed the change in resistance when the drill perforated the upper cortical bone. All five dentists were able to detect when the drill made contact with lingual cortical bone and when the lingual bone was perforated. This project successfully developed a dental implant surgery simulator that allows users to experience the forces necessary to drill through types of bone encountered during osteotomy. Furthermore, the researchers were able to build a device by which excessive drilling simulates a situation in which the lingual cortical bone is perforated--a situation that could lead to negative repercussions in a clinical setting. The simulator was found to be useful to train users to recognize the differences in resistance when drilling through the mandibular bone.

  10. The Risk of Misdiagnosing the Primary Site Responsible for Bone Metastases in Patients With Chronic Lymphocytic Leukemia and a Second Primary Carcinoma

    PubMed Central

    Hatoum, Georges; Meshkin, Cyrus; Alkhunaizi, Sufana; Levene, Richard; Formoso-Onofrio, Julie

    2015-01-01

    Chronic lymphocytic leukemia (CLL) is a common malignancy which may coexist with other primary cancers. CLL is rarely the cause of solitary bone lesions; such lesions in the context of CLL are believed to result from either Richter’s transformation or metastasis from another primary malignancy. Renal cell carcinoma (RCC), on the other hand, is a malignancy which frequently metastasizes to bone and may cause an osteolytic solitary bone lesion. The origin of a solitary bone lesion in a patient with multiple potential primary malignancies has prognostic implications and affects treatment protocol, and as such must be diagnosed accurately. We describe a patient with CLL and a history of RCC who is found to have an incidental solitary bone lesion of the T11 vertebra. After two separate CT-guided biopsies revealed various lymphoid cell predominance and no evidence of RCC, treatment with low dose external beam radiation therapy (EBRT) was employed. Post-therapy MRI showed further propagation of the lesion. Surgical corpectomy was subsequently performed and postoperative pathology of the lesion was consistent with RCC. The patient was treated with bisphosphonates and a higher dose of EBRT. Our case illustrates the importance of surgical excisional biopsy for accurately diagnosing the primary source metastatic to the bone in a patient with CLL and another potential primary cancer. PMID:29147427

  11. Knee joint transplantation combined with surgical angiogenesis in rabbits – a new experimental model

    PubMed Central

    Kremer, Thomas; Giusti, Guilherme; Friedrich, Patricia F.; Willems, Wouter; Bishop, Allen T.; Giessler, Goetz A.

    2012-01-01

    Summary Purpose We have previously described a means to maintain bone allotransplant viability, without long-term immune modulation, replacing allogenic bone vasculature with autogenous vessels. A rabbit model for whole knee joint transplantation was developed and tested using the same methodology, initially as an autotransplant. Materials/Methods Eight New Zealand White rabbit knee joints were elevated on a popliteal vessel pedicle to evaluate limb viability in a non-survival study. Ten additional joints were elevated and replaced orthotopically in a fashion identical to allotransplantation, obviating only microsurgical repairs and immunosuppression. A superficial inferior epigastric facial (SIEF) flap and a saphenous arteriovenous (AV) bundle were introduced into the femur and tibia respectively, generating a neoangiogenic bone circulation. In allogenic transplantation, this step maintains viability after cessation of immunosuppression. Sixteen weeks later, x-rays, microangiography, histology, histomorphometry and biomechanical analysis were performed. Results Limb viability was preserved in the initial 8 animals. Both soft tissue and bone healing occurred in 10 orthotopic transplants. Surgical angiogenesis from the SIEF flap and AV bundle was always present. Bone and joint viability was maintained, with demonstrable new bone formation. Bone strength was less than the opposite side. Arthrosis and joint contractures were frequent. Conclusion We have developed a rabbit knee joint model and evaluation methods suitable for subsequent studies of whole joint allotransplantation. PMID:22113889

  12. Carbon/PEEK composite materials as an alternative for stainless steel/titanium hip prosthesis: a finite element study.

    PubMed

    Rezaei, Farshid; Hassani, Kamran; Solhjoei, Nosratollah; Karimi, Alireza

    2015-12-01

    Total hip replacement (THR) has been ranked within the most typical surgical processes in the world. The durability of the prosthesis and loosening of prosthesis are the main concerns that mostly reported after THR surgeries. In THR, the femoral prosthesis can be fixed by either cement or cementless methods in the patient's bones. In both procedures, the stability of the prosthesis in the hosted bone has a key asset in its long-term durability and performance. This study aimed to execute a comparative finite element simulation to assess the load transfer between the prosthesis, which is made of carbon/PEEK composite and stainless steel/titanium, and the femur bone. The mechanical behavior of the cortical bone was assumed as a linear transverse isotropic while the spongy bone was modeled like a linear isotropic material. The implants were made of stainless steel (316L) and titanium alloy as they are common materials for implants. The results showed that the carbon/PEEK composites provide a flatter load transfer from the upper body to the leg compared to the stainless steel/titanium prosthesis. Furthermore, the results showed that the von Mises stress, principal stress, and the strain in the carbon/PEEK composites prosthesis were significantly lower than that made of the stainless steel/titanium. The results also imply that the carbon/PEEK composites can be applied to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease the stress shielding and interface stress. These findings will help clinicians and biomedical experts to increase their knowledge about the hip replacement.

  13. Surgical Management of Spinal Conditions in the Elderly Osteoporotic Spine.

    PubMed

    Goldstein, Christina L; Brodke, Darrel S; Choma, Theodore J

    2015-10-01

    Osteoporosis, the most common form of metabolic bone disease, leads to alterations in bone structure and density that have been shown to compromise the strength of spinal instrumentation. In addition, osteoporosis may contribute to high rates of fracture and instrumentation failure after long posterior spinal fusions, resulting in proximal junctional kyphosis and recurrent spinal deformity. As increasing numbers of elderly patients present for surgical intervention for degenerative and traumatic spinal pathologies, current and future generations of spine surgeons will increasingly be faced with the challenge of obtaining adequate fixation in osteoporotic bone. The purpose of this review is to familiarize the reader with the impact of osteoporosis on spinal instrumentation, the broad variety of techniques that have been developed for addressing these issues, and the biomechanical and clinical evidence in support of the use of these techniques.

  14. A review of simulation platforms in surgery of the temporal bone.

    PubMed

    Bhutta, M F

    2016-10-01

    Surgery of the temporal bone is a high-risk activity in an anatomically complex area. Simulation enables rehearsal of such surgery. The traditional simulation platform is the cadaveric temporal bone, but in recent years other simulation platforms have been created, including plastic and virtual reality platforms. To undertake a review of simulation platforms for temporal bone surgery, specifically assessing their educational value in terms of validity and in enabling transition to surgery. Systematic qualitative review. Search of the Pubmed, CINAHL, BEI and ERIC databases. Assessment of reported outcomes in terms of educational value. A total of 49 articles were included, covering cadaveric, animal, plastic and virtual simulation platforms. Cadaveric simulation is highly rated as an educational tool, but there may be a ceiling effect on educational outcomes after drilling 8-10 temporal bones. Animal models show significant anatomical variation from man. Plastic temporal bone models offer much potential, but at present lack sufficient anatomical or haptic validity. Similarly, virtual reality platforms lack sufficient anatomical or haptic validity, but with technological improvements they are advancing rapidly. At present, cadaveric simulation remains the best platform for training in temporal bone surgery. Technological advances enabling improved materials or modelling mean that in the future plastic or virtual platforms may become comparable to cadaveric platforms, and also offer additional functionality including patient-specific simulation from CT data. © 2015 John Wiley & Sons Ltd.

  15. Staphylococcus aureus Biofilms Decrease Osteoblast Viability, Inhibits Osteogenic Differentiation, and Increases Bone Resorption in vitro

    DTIC Science & Technology

    2013-06-01

    severe and often debilitating disease characterized by inflammatory destruction of bone. Despite treatment, chronic infection often develops which is...biofilms may contribute to bone loss during chronic osteomyelitis simultaneously by: (1) reducing osteoblast viability and osteogenic potential thereby...accounting for more than half of all cases [1]. Despite treatment and surgical intervention up to 30% of osteomyelitis cases progress into a chronic

  16. Treatment outcomes of temporal bone osteoradionecrosis.

    PubMed

    Kammeijer, Quinten; van Spronsen, Erik; Mirck, Piet G B; Dreschler, Wouter A

    2015-04-01

    To investigate the clinical relevance of the classification systems used for temporal bone osteoradionecrosis (ORN) and to define a treatment protocol for temporal bone ORN. Retrospective case series. Amsterdam, department of otorhinolaryngology and head and neck surgery. Classification of temporal bone ORN was performed through use of clinical data and radiologic imaging. Outcomes of conservative and surgical treatment were investigated and compared for different grades of ORN. Of the 49 ears included in this study, 35 were primarily treated conservatively. At start of conservative treatment, 23 were classified as a localized and 8 as a diffuse form of ORN; 4 could not be classified. There was a significant difference in clinical outcome between the localized and diffuse forms of ORN (χ(2) = 5.862, P = .015), and mastoid air cell destruction on preoperative computed tomography scan was found to be a significant predictor for a negative outcome of conservative treatment (χ(2) = 4.34, P = .037). Fourteen ears with diffuse ORN were primarily treated surgically, and 11 were secondarily treated surgically following a period of conservative treatment. Twenty-two patients were treated with subtotal petrosectomy, of which 20 were cured. Three patients were treated with canal wall down mastoidectomy, and 2 had recurrence of disease. Ramsden's classification system is clinically relevant in predicting conservative treatment outcomes. Mastoid air cell destruction on computed tomography differentiates between the localized and diffuse forms of ORN. Given our results and experience with treating temporal bone ORN, we propose a treatment protocol. © American Academy of Otolaryngology—Head and Neck Surgery Foundation 2015.

  17. Clinical and Radiographic Comparative Evaluation of Buccal and Palatal Corticotomy with Buccal Corticotomy in Periodontally Accelerated Osteogenic Orthodontics with Surgical Bur

    PubMed Central

    Addanki, Pavankumar; Gooty, Jagadish Reddy; Palaparthy, Rajababu

    2017-01-01

    Background: Periodontally accelerated osteogenic orthodontics is a clinical procedure that combines selective corticotomy, particulate grafting, and application of orthodontics. It reduces treatment time, increases stability of teeth, and prevents relapse of orthodontic tooth moment. The present study was aimed to explore the clinical and radiographic comparison of bone density changes, retraction time differences in buccal and palatal corticotomy with buccal corticotomy which was done by surgical bur. Materials and Methods: A split-mouth was designed in 16 patients and divided into right (buccal and palatal corticotomy) (Group I), left (buccal corticotomy) (Group II) sides. In both groups, decortication was done with surgical bur. Clinical parameters such as gingival bleeding index and probing pocket depth were recorded at baseline, 1 month, 3 months, and 6 months. Bone density changes were measured by computed tomography at baseline and after 6 months after surgery and also used for evaluating differences in bone density changes between two groups. Retraction time differences were also measured in both groups. Results: In both groups, there was significant difference between bone density changes at baseline and 6 months after surgery. However, the difference between two groups was not significant. The difference in clinical parameters between two groups was not significant. The difference in retraction time differences was not significant. Conclusion: Within limits of the study, it may be concluded that there was difference between bone density changes before and 6 months after surgery. Difference in total treatment time found to be no significant between two groups. PMID:28839422

  18. The dawn of computer-assisted robotic osteotomy with ytterbium-doped fiber laser.

    PubMed

    Sotsuka, Yohei; Nishimoto, Soh; Tsumano, Tomoko; Kawai, Kenichiro; Ishise, Hisako; Kakibuchi, Masao; Shimokita, Ryo; Yamauchi, Taisuke; Okihara, Shin-ichiro

    2014-05-01

    Currently, laser radiation is used routinely in medical applications. For infrared lasers, bone ablation and the healing process have been reported, but no laser systems are established and applied in clinical bone surgery. Furthermore, industrial laser applications utilize computer and robot assistance; medical laser radiations are still mostly conducted manually nowadays. The purpose of this study was to compare the histological appearance of bone ablation and healing response in rabbit radial bone osteotomy created by surgical saw and ytterbium-doped fiber laser controlled by a computer with use of nitrogen surface cooling spray. An Ytterbium (Yb)-doped fiber laser at a wavelength of 1,070 nm was guided by a computer-aided robotic system, with a spot size of 100 μm at a distance of approximately 80 mm from the surface. The output power of the laser was 60 W at the scanning speed of 20 mm/s scan using continuous wave system with nitrogen spray level 0.5 MPa (energy density, 3.8 × 10(4) W/cm(2)). Rabbits radial bone osteotomy was performed by an Yb-doped fiber laser and a surgical saw. Additionally, histological analyses of the osteotomy site were performed on day 0 and day 21. Yb-doped fiber laser osteotomy revealed a remarkable cutting efficiency. There were little signs of tissue damage to the muscle. Lased specimens have shown no delayed healing compared with the saw osteotomies. Computer-assisted robotic osteotomy with Yb-doped fiber laser was able to perform. In rabbit model, laser-induced osteotomy defects, compared to those by surgical saw, exhibited no delayed healing response.

  19. Surgically Facilitated Orthodontic Therapy: Optimizing Dentoalveolar Bone and Space Appropriation for Facially Prioritized Interdisciplinary Dentofacial Therapy.

    PubMed

    Mandelaris, George A; DeGroot, Bradley S; Relle, Robert; Shah, Brian; Huang, Iwei; Vence, Brian S

    2018-03-01

    Comorbidities that negatively impact orthodontic (malocclusion), periodontal (periodontitis, deficient dentoalveolar bone volume, mucogingival), and prosthetic (structural integrity compromise from caries, attrition, and erosion) conditions can affect the general health of the patient. In addition, emerging data highlights the importance of undiagnosed airway volume deficiencies and sleep-disordered breathing conditions in the adult and pediatric population. Deficiencies in dentoalveolar bone and discrepancies in skeletal relationships can impact the volume of hard- and soft-tissue structures of the periodontium and decrease oral cavity volume. Contemporary interdisciplinary dentofacial therapy (IDT) is a key process for addressing the comprehensive problems of patients based on etiology, homeostasis, and sustainability of physiologically sound outcomes. These provide the patient with sustainable esthetics and function. Surgically facilitated orthodontic therapy (SFOT) uses corticotomies and dentoalveolar bone decortication to stimulate the regional acceleratory phenomenon and upregulate bone remodeling and tooth movement as a part of orthodontic decompensation. It also generally includes guided periodontal tissue regeneration and/or dentoalveolar bone augmentation. SFOT as a part of IDT is demanding and requires extensive attentiveness and communication among all team members. This article focuses on the role of SFOT as an integral component of contemporary IDT to facilitate highly predictable and sustainable outcomes.

  20. Cervical digit in a child

    PubMed Central

    Tong, Min-Ji; Xiang, Guang-Heng; He, Zi-Li; Xu, Hua-Zi; Tian, Nai-Feng

    2017-01-01

    Abstract Background: A “digit-like” bone is a rare developmental anomaly that is usually seen in the pelvic or thoracic regions. Such an anomaly in the cervical spine is extremely rare and few cases have been reported. We present a patient with an anomalous bone posterior to a cervical vertebra. The patient was admitted to our hospital with a gradually growing hard neck mass and esthetic complaints. Physical examination, radiographs, reconstructed computed tomography, and magnetic resonance imaging revealed a digit-like bone posterior to the cervical spine. The patient was diagnosed with a “cervical digit.” Through a posterior midline approach, the anomalous bone was excised because of its gradually increasing size and esthetic complaints. Results: Intraoperatively, the bony mass was found to have a pseudoarticulation with the spinous process of C5 (the fifth cervical vertebra). The specimen consisted of normal bone and cartilage. The child returned to a normal life postoperatively with no symptoms. There was no recurrence at the 2-year follow-up. Conclusion: A congenital cervical digit is a rare deformity. A detailed clinical workup and advanced imaging examinations are useful for diagnosing such conditions. Esthetic complaints contribute to surgical indications. This is the first cervical digit managed with surgical excision of the anomalous bone and had a favorable outcome. PMID:29390517

  1. An Er:YAG laser bone cutting manipulator for precise rotational acetabular osteotomy.

    PubMed

    Kim, D; Owada, H; Hata, N; Dohi, T

    2004-01-01

    Rotational acetabular osteotomy (RAO) has an important advantage in that surgical bony defects are reconstructed with a patients' own tissue. We propose a surgical robot for the RAO using Er:YAG laser irradiating mounted on iliac bone to operate RAO precisely and to reduce recovery and trauma. A water-cooling Er:YAG laser (30 J/cm/sup 2/, l=2.94 mum, 20 Hz, 200 msec) that used optical fiber was operated 4-8 irradiation-overlapping ratio. We kept the distance between the laser and the bone at 0.25 mm using force sensor and spring to maintain effective ablation. Swine scapulae were ablated and performance was evaluated. The manipulator was operated mounting on iliac bone to get a filed position whereby resulting in precise bone cutting. The precision of the manipulator was within 0.3 mm and the efficiency of laser bone ablations per unit time optimized to 0.21 mm/sup 3//secW at the overlapping ratio of the irradiation area was 0.8, meaning a given ablated area was irradiated five times. The troughs showed m charring at this condition and the temperature of the surface was raised to 41.3 degrees C and it lasted only 5 seconds. We are sure that this research will be applied to orthopedics in the near future.

  2. 3D Printing Surgical Implants at the clinic: A Experimental Study on Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Liu, An; Xue, Guang-huai; Sun, Miao; Shao, Hui-feng; Ma, Chi-yuan; Gao, Qing; Gou, Zhong-ru; Yan, Shi-gui; Liu, Yan-ming; He, Yong

    2016-01-01

    Desktop three-dimensional (3D) printers (D3DPs) have become a popular tool for fabricating personalized consumer products, favored for low cost, easy operation, and other advantageous qualities. This study focused on the potential for using D3DPs to successfully, rapidly, and economically print customized implants at medical clinics. An experiment was conducted on a D3DP-printed anterior cruciate ligament surgical implant using a rabbit model. A well-defined, orthogonal, porous PLA screw-like scaffold was printed, then coated with hydroxyapatite (HA) to improve its osteoconductivity. As an internal fixation as well as an ideal cell delivery system, the osteogenic scaffold loaded with mesenchymal stem cells (MSCs) were evaluated through both in vitro and in vivo tests to observe bone-ligament healing via cell therapy. The MSCs suspended in Pluronic F-127 hydrogel on PLA/HA screw-like scaffold showed the highest cell proliferation and osteogenesis in vitro. In vivo assessment of rabbit anterior cruciate ligament models for 4 and 12 weeks showed that the PLA/HA screw-like scaffold loaded with MSCs suspended in Pluronic F-127 hydrogel exhibited significant bone ingrowth and bone-graft interface formation within the bone tunnel. Overall, the results of this study demonstrate that fabricating surgical implants at the clinic (fab@clinic) with D3DPs can be feasible, effective, and economical. PMID:26875826

  3. Piezolelectric surgery in dentistry: a review.

    PubMed

    Carini, F; Saggese, V; Porcaro, G; Baldoni, M

    2014-01-01

    In the last ten years was observed a significant increase of publications about piezoelectric bone surgery. The purpose of this review was to define the state of art and to realize a comparison between piezoelectric devices and manual or rotating traditional techniques, analyzing advantages and disadvantages from a clinical and histological point of view for various dental procedures. The literature review has been carried out using medical databases on line: MEDLINE and COCHRANE LIBRARY. The authors selected 37 publications about dental field and consistent with inclusion criteria established. From the clinical point of view, the analysis of selected publications concerning procedures such as maxillary sinus lift, alveolar ridge expansion, samples of autologous bone, etc, showed surgical trauma reduction, especially towards to soft and nervous tissues, surgical mini-invasiveness, cut precision and selectivity and speed of learning guaranteed by piezoelectric devices compared to traditional ones. Histologically, however, the study of biology and postintervention bone tissue healing showed a lower loss of bone with piezoelectric instruments than with conventional devices, as well as a better healing quality by reducing patient's postsurgery morbidity. The use of piezoelectric devices seems thus to simplify different sinus lift surgical procedures and to allow greater predictability, although some studies reveal that there are not substantial differences in comparison of long-term results between conventional and piezoelectric instruments and also criticize their increase in operation time.

  4. Detailed anatomy knowledge: first step to approach petroclival meningiomas through the petrous apex. Anatomy lab experience and surgical series.

    PubMed

    Altieri, Roberto; Sameshima, Tetsuro; Pacca, Paolo; Crobeddu, Emanuela; Garbossa, Diego; Ducati, Alessandro; Zenga, Francesco

    2017-04-01

    Petroclival meningiomas are a challenge for neurosurgeons due to the complex anatomy of the region that is rich of vessels and nerves. A perfect and detailed knowledge of the anatomy is very demanding in neurosurgery, especially in skull base surgery. The authors describe the microsurgical anatomy to perform an anterior petrosectomy based on their anatomical and surgical experience and perform a literature review. The temporal bone is the most complex and fascinating bone of skull base. The apex is located in the angle between the greater wing of the sphenoid and the occipital bone. Removing the petrous apex exposes the clivus. The approach directed through the temporal bone in this anatomical area is referred to as an anterior petrosectomy. The area that must be drilled is the rhomboid fossa that is defined by the Kawase, premeatal, and postmeatal triangles. In Division of Neurosurgery - University of Turin, 130 patients, from August 2013 to September 2015, underwent surgical resection of intracranial meningiomas. In this group, we have operated 7 PCMs and 5 of these were approached performing an anterior petrosectomy with good results. In our conclusions, we feel that this surgery require an advanced knowledge of human anatomy and a specialized training in interpretation of radiological and microsurgical anatomy both in the dissection lab and in the operating room.

  5. [Case report: comprehensive treatment of forefoot with double brachymetatarsia in one surgical stage].

    PubMed

    Caldiño-Lozada, I; Gallegos-de la Torre, O; Esperón-Hernández, R

    2017-01-01

    Brachymetatarsia (shortening of the metatarsal) directly affects the transversal arch of the foot causing severe deformities, such as hallux valgus, divergent toes, overlapping toes, metatarsalgia, all of these alter the biomechanics of the foot and gait. Treatment consists of two main techniques, one-stage lengthening with bone graft or elongation through callotaxis with external fixator; there are variants of both techniques used to minimize the disadvantages of each. The objective of treatment must be to return the structural harmony to the forefoot, improving the biomechanics, resulting in a satisfactory outcome for the patients. This article presents a surgical treatment for feet with closed physis to obtain the appropriate metatarsal formula and to reestablish aesthetics and function. This case was treated by means of one-stage lengthening with bone graft to the affected metatarsal; shortening of the adjacent metatarsals; hallux valgus alignment through the necessary osteotomies and the treatment of deformities of the lesser toes as needed. This surgical technique has as one of its advantages the correction of the entire forefoot at one time, without the need of an external fixator and its required postoperative care. Its main disadvantages are its dependence on structural bone graft and the need of postoperative dressing until healing of the bone has taken place. Satisfactory clinical and radiographical outcomes were obtained in treated patient.

  6. [Miniplate internal fixation and autogenous iliac bone graft in surgical treatment of old metatarsal fractures].

    PubMed

    Pan, Hao; Yu, Guangrong; Xiong, Wen; Zhao, Zhiming; Ding, Fan; Zheng, Qiong; Kan, Wushen

    2011-07-01

    To summarize the experience of treating old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone. Between May 2009 and July 2010, 7 patients with old metatarsal fractures were treated surgically, including 5 multi-metatarsal fractures and 2 single metatarsal fractures. There were 5 males and 2 females aged from 25 to 43 years (mean, 33 years). The time from fracture to operation was 4-12 weeks. The X-ray films showed that a small amount of callus formed at both broken ends with shortening, angulation, or rotation displacement. The surgical treatments included open reduction, internal fixation by miniplate, and autogenous iliac bone graft (1.5-2.5 cm(3)). The external plaster fixation was used in all patients for 4 to 6 weeks postoperatively (mean, 5 weeks). All incisions healed by first intention. The 7 patients were followed up 8-18 months (mean, 13.5 months). The clinical fracture healing time was 6 to 12 weeks postoperatively (mean, 8.4 weeks). No pain of planta pedis occurred while standing and walking. The American Orthopaedic Foot and Ankle Society (AOFAS) mesopedes and propodium score was 75-96 (mean, 86.4). It has the advantages of reliable internal fixation, high fracture healing rate, less complications to treat old metatarsal fractures with surgery methods of miniplate internal fixation and autogenous iliac bone graft, so it is an effective treatment method.

  7. Mesenchymal Stem Cells and Platelet Gel Improve Bone Deposition within CAD-CAM Custom-Made Ceramic HA Scaffolds for Condyle Substitution

    PubMed Central

    Ciocca, L.; Donati, D.; Ragazzini, S.; Dozza, B.; Rossi, F.; Fantini, M.; Spadari, A.; Romagnoli, N.; Landi, E.; Tampieri, A.; Piattelli, A.; Iezzi, G.; Scotti, R.

    2013-01-01

    Purpose. This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. Methods. Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. Results. Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. Conclusion. The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs. PMID:24073409

  8. Utilization of ring-shaped bone allograft for surgical treatment of adolescent post-tubercular kyphosis: A retrospective study.

    PubMed

    Yin, Xiang; Liu, Peng; Liu, Yao-Yao; Fan, Wei-Li; Liu, Bai-Yi; Zhao, Jian-Hua

    2017-06-01

    This study aimed to investigate the mid-term outcome of ring-shaped bone allografts in the surgical treatment of adolescent post-tubercular kyphosis secondary to spinal tuberculosis.The records of adolescent patients diagnosed with spinal tuberculosis who received treatment in our department between 2009 and 2013 were retrospectively reviewed. The anterior approach was used in cases of cervical kyphosis and the posterior approach was used in cases of thoracic and lumbar kyphosis. During the surgery, the ring-shaped bone was used as a structural bone graft associated with the cancellous bone filing in the center portion of the ring shape. Cobb's angle, signs of spinal infusion on computed tomography, and complications were followed up.A total of 25 patients were included in our study. Among them, 3 involved the cervical region, 5 involved the thoracic region, 8 involved the thoracolumbar region, and 9 involved the lumbar region. The preoperative kyphosis deformity was a mean 65° Cobb's angle (40°-97°) compared to the postoperative 14° Cobb's angle (10°-21°) for an average correction of 51°. All wounds healed well without graft rejection. All patients achieved bone fusion 3 months postoperative for a 100% fusion rate.Our results show that the ring-shaped allograft bone is an effective option for the treatment of adolescent kyphosis. The ring-shaped allograft bone demonstrated satisfactory mechanical strength and vertebral fusion without mid-term metallic toxicity.

  9. Utilization of ring-shaped bone allograft for surgical treatment of adolescent post-tubercular kyphosis

    PubMed Central

    Yin, Xiang; Liu, Peng; Liu, Yao-yao; Fan, Wei-Li; Liu, Bai-yi; Zhao, Jian-Hua

    2017-01-01

    Abstract This study aimed to investigate the mid-term outcome of ring-shaped bone allografts in the surgical treatment of adolescent post-tubercular kyphosis secondary to spinal tuberculosis. The records of adolescent patients diagnosed with spinal tuberculosis who received treatment in our department between 2009 and 2013 were retrospectively reviewed. The anterior approach was used in cases of cervical kyphosis and the posterior approach was used in cases of thoracic and lumbar kyphosis. During the surgery, the ring-shaped bone was used as a structural bone graft associated with the cancellous bone filing in the center portion of the ring shape. Cobb's angle, signs of spinal infusion on computed tomography, and complications were followed up. A total of 25 patients were included in our study. Among them, 3 involved the cervical region, 5 involved the thoracic region, 8 involved the thoracolumbar region, and 9 involved the lumbar region. The preoperative kyphosis deformity was a mean 65° Cobb's angle (40°–97°) compared to the postoperative 14° Cobb's angle (10°–21°) for an average correction of 51°. All wounds healed well without graft rejection. All patients achieved bone fusion 3 months postoperative for a 100% fusion rate. Our results show that the ring-shaped allograft bone is an effective option for the treatment of adolescent kyphosis. The ring-shaped allograft bone demonstrated satisfactory mechanical strength and vertebral fusion without mid-term metallic toxicity. PMID:28614236

  10. Reduction of bone resorption by the application of fibrin glue in the reconstruction of the alveolar cleft.

    PubMed

    Segura-Castillo, José L; Aguirre-Camacho, Humberto; González-Ojeda, Alejandro; Michel-Perez, Jorge

    2005-01-01

    A major complication in 30% to 75% of cases of surgical treatment of alveolar cleft is resorption of the bone graft. A treatment alternative is the application of fibrin glue, which has the capacity to favor the integration of the graft. The main objective of the study was to evaluate if the use of the fibrin glue reduces bone resorption when it is applied locally. The authors designed a randomized clinical trial. Patients were divided into two groups: group 1, fibrin glue; and group 2, control. Pre- and postoperative graft volume, bone density, bone quality (Lekholm and Zarb, and Norton and Gamble classifications), and postoperative complications were evaluated. The follow-up for all patients was 3 months after discharge. Twenty-seven patients were surgically treated, 13 in group 1 and 14 in group 2. Group 1 had increased graft volume compared with group 2 (64.32 cm v 21.70 cm; P < 0.0001). Bone density was higher in group 1 than in group 2 (396.57 v 245.68; P > 0.076). Bone quality was type 1, 2 and 3 and 4 in group 1. Resorption in group 2 was 62.26%; in group 1, it was 29.72% (P > 0.081). The observed complications were infection and dehiscence of sutures (P > 0.537). The authors conclude that the fibrin glue significantly diminishes bone resorption, allowing improved graft integration and quality.

  11. Periodontal Tissues, Maxillary Jaw Bone, and Tooth Regeneration Approaches: From Animal Models Analyses to Clinical Applications

    PubMed Central

    Batool, Fareeha; Strub, Marion; Petit, Catherine; Bugueno, Isaac Maximiliano; Bornert, Fabien; Clauss, François; Kuchler-Bopp, Sabine; Benkirane-Jessel, Nadia

    2018-01-01

    This review encompasses different pre-clinical bioengineering approaches for periodontal tissues, maxillary jaw bone, and the entire tooth. Moreover, it sheds light on their potential clinical therapeutic applications in the field of regenerative medicine. Herein, the electrospinning method for the synthesis of polycaprolactone (PCL) membranes, that are capable of mimicking the extracellular matrix (ECM), has been described. Furthermore, their functionalization with cyclosporine A (CsA), bone morphogenetic protein-2 (BMP-2), or anti-inflammatory drugs’ nanoreservoirs has been demonstrated to induce a localized and targeted action of these molecules after implantation in the maxillary jaw bone. Firstly, periodontal wound healing has been studied in an induced periodontal lesion in mice using an ibuprofen-functionalized PCL membrane. Thereafter, the kinetics of maxillary bone regeneration in a pre-clinical mouse model of surgical bone lesion treated with BMP-2 or BMP-2/Ibuprofen functionalized PCL membranes have been analyzed by histology, immunology, and micro-computed tomography (micro-CT). Furthermore, the achievement of innervation in bioengineered teeth has also been demonstrated after the co-implantation of cultured dental cell reassociations with a trigeminal ganglia (TG) and the cyclosporine A (CsA)-loaded poly(lactic-co-glycolic acid) (PLGA) scaffold in the jaw bone. The prospective clinical applications of these different tissue engineering approaches could be instrumental in the treatment of various periodontal diseases, congenital dental or cranio-facial bone anomalies, and post-surgical complications. PMID:29772691

  12. Mesenchymal stem cells and platelet gel improve bone deposition within CAD-CAM custom-made ceramic HA scaffolds for condyle substitution.

    PubMed

    Ciocca, L; Donati, D; Ragazzini, S; Dozza, B; Rossi, F; Fantini, M; Spadari, A; Romagnoli, N; Landi, E; Tampieri, A; Piattelli, A; Iezzi, G; Scotti, R

    2013-01-01

    This study evaluated the efficacy of a regenerative approach using mesenchymal stem cells (MSCs) and CAD-CAM customized pure and porous hydroxyapatite (HA) scaffolds to replace the temporomandibular joint (TMJ) condyle. Pure HA scaffolds with a 70% total porosity volume were prototyped using CAD-CAM technology to replace the two temporomandibular condyles (left and right) of the same animal. MSCs were derived from the aspirated iliac crest bone marrow, and platelets were obtained from the venous blood of the sheep. Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Sheep were sacrificed 4 months postoperatively. The HA scaffolds were explanted, histological specimens were prepared, and histomorphometric analysis was performed. Analysis of the porosity reduction for apposition of newly formed bone showed a statistically significant difference in bone formation between condyles loaded with MSC and condyles without (P < 0.05). The bone ingrowth (BI) relative values of split-mouth comparison (right versus left side) showed a significant difference between condyles with and without MSCs (P < 0.05). Analysis of the test and control sides in the same animal using a split-mouth study design was performed; the condyle with MSCs showed greater bone formation. The split-mouth design confirmed an increment of bone regeneration into the HA scaffold of up to 797% upon application of MSCs.

  13. Large animal model for osteoporosis in humans: the ewe.

    PubMed

    Oheim, R; Amling, M; Ignatius, A; Pogoda, P

    2012-11-12

    Osteoporosis is a chronic systemic disease characterised by bone loss and microarchitectural deterioration. Since the underlying regulatory mechanisms are still not fully understood and treatment options are not satisfactorily resolved, massive efforts are underway to further investigate this critical illness. Large animal models are stipulated, e.g. by the Food and Drug Administration, for preclinical prevention and intervention studies related to osteoporosis research; in this context, the ewe has already proven its value for orthopaedic research. Although oestrogen deficiency doubtless influences bone metabolism in sheep, the ovariectomised ewe seems unsuitable as a model for postmenopausal osteoporosis and bone loss induction due to its unreliable impact on bone mass and structure. In contrast, glucocorticoid treatment has a major impact on bone turnover and leads to bone conditions comparable to those found in steroid-treated humans. However, adverse side effects can be dramatic resulting in unacceptable discomfort and illness of the experimental animals. Further improvements are therefore essential to judge this model as ethically appropriate. Additionally, models for osteoporosis induced by surgical interventions of central regulatory mechanisms seem to be attractive, as remarkable bone loss is induced by only one surgical procedure without any further treatment. Taken together, different ewe models for osteoporosis have been successfully established and are invaluable for orthopaedic research. However, the search for a 'perfect' large remodelling animal model - in terms of mimicking the human disease and compatibility of bone loss, and without ethical concerns - is still on-going.

  14. A 6-DOF parallel bone-grinding robot for cervical disc replacement surgery.

    PubMed

    Tian, Heqiang; Wang, Chenchen; Dang, Xiaoqing; Sun, Lining

    2017-12-01

    Artificial cervical disc replacement surgery has become an effective and main treatment method for cervical disease, which has become a more common and serious problem for people with sedentary work. To improve cervical disc replacement surgery significantly, a 6-DOF parallel bone-grinding robot is developed for cervical bone-grinding by image navigation and surgical plan. The bone-grinding robot including mechanical design and low level control is designed. The bone-grinding robot navigation is realized by optical positioning with spatial registration coordinate system defined. And a parametric robot bone-grinding plan and high level control have been developed for plane grinding for cervical top endplate and tail endplate grinding by a cylindrical grinding drill and spherical grinding for two articular surfaces of bones by a ball grinding drill. Finally, the surgical flow for a robot-assisted cervical disc replacement surgery procedure is present. The final experiments results verified the key technologies and performance of the robot-assisted surgery system concept excellently, which points out a promising clinical application with higher operability. Finally, study innovations, study limitations, and future works of this present study are discussed, and conclusions of this paper are also summarized further. This bone-grinding robot is still in the initial stage, and there are many problems to be solved from a clinical point of view. Moreover, the technique is promising and can give a good support for surgeons in future clinical work.

  15. In vivo testing of a biodegradable woven fabric made of bioactive glass fibers and PLGA80--a pilot study in the rabbit.

    PubMed

    Alm, Jessica J; Frantzén, Janek P A; Moritz, Niko; Lankinen, Petteri; Tukiainen, Mikko; Kellomäki, Minna; Aro, Hannu T

    2010-05-01

    The purpose of this study was to perform an intra-animal comparison of biodegradable woven fabrics made of bioactive glass (BG) fibers and poly(L-lactide-co-glycolide) 80/20 copolymer (PLGA(80)) fibers or PLGA(80) fibers alone, in surgical stabilization of bone graft. The BG fibers (BG 1-98) were aimed to enhance bone growth at site of bone grafting, whereas the PLGA component was intended to provide structural strength and flexibility to the fabric. Bone formation was analyzed qualitatively by histology and quantitatively by peripheral quantitative computed tomography (pQCT) at 12 weeks. The surgical handling properties of the control PLGA(80) fabric were more favorable. Both fabrics were integrated with the cortical bone surfaces, but BG fibers showed almost complete resorption. There were no signs of adverse local tissue reactions. As a proof of material integration and induced new bone formation, there was a significant increase in bone volume of the operated femurs compared with the contralateral intact bone (25% with BG/PLGA(80) fabric, p < 0.001 and 28% with the control PLGA(80) fabric, p = 0.006). This study failed to demonstrate the previously seen positive effect of BG 1-98 on osteogenesis, probably due to the changed resorption properties of BG in the form of fibers. Therefore, the feasibility and safety of BG as fibers needs to be reevaluated before use in clinical applications. (c) 2010 Wiley Periodicals, Inc.

  16. Virtual reality simulation in neurosurgery: technologies and evolution.

    PubMed

    Chan, Sonny; Conti, François; Salisbury, Kenneth; Blevins, Nikolas H

    2013-01-01

    Neurosurgeons are faced with the challenge of learning, planning, and performing increasingly complex surgical procedures in which there is little room for error. With improvements in computational power and advances in visual and haptic display technologies, virtual surgical environments can now offer potential benefits for surgical training, planning, and rehearsal in a safe, simulated setting. This article introduces the various classes of surgical simulators and their respective purposes through a brief survey of representative simulation systems in the context of neurosurgery. Many technical challenges currently limit the application of virtual surgical environments. Although we cannot yet expect a digital patient to be indistinguishable from reality, new developments in computational methods and related technology bring us closer every day. We recognize that the design and implementation of an immersive virtual reality surgical simulator require expert knowledge from many disciplines. This article highlights a selection of recent developments in research areas related to virtual reality simulation, including anatomic modeling, computer graphics and visualization, haptics, and physics simulation, and discusses their implication for the simulation of neurosurgery.

  17. [A rare tumor of the infratemporal fossa].

    PubMed

    Bourhaleb, Z; Chekrine, T; Bouamama, I; Bouchbika, Z; Benchakroun, N; Jouhadi, H; Tawfiq, N; Sahraoui, S; Benider, A

    2010-06-01

    Giant cell tumors of bone (GCT) are usually benign and relatively rare. They have an aggressive behavior and an unpredictable prognosis. They occur mainly in the young adult, with a preferential localization in long bones. We report a giant cell infratemporal fossa tumor. A 55-year-old female patient consulted for swelling in the right cheek. Surgical excision was incomplete because of the subtemporal tumor localization. Histological assessment proved a GCT. Forty-five grays postoperative external radiotherapy was applied to the surgical site. The patient had local control at the 12-month follow-up. GCTs are seldom observed in the facial skeleton (2%). The recommended treatment is surgery. Radiotherapy can be indicated in case of incomplete or impossible surgical excision, or when surgery would be responsible for a major functional deficit. Copyright 2010 Elsevier Masson SAS. All rights reserved.

  18. Immediate implants placed into infected sockets: a case report with 3-year follow-up.

    PubMed

    Naves, Marina de Melo; Horbylon, Bruna Zacharias; Gomes, Camila de Freitas; Menezes, Helder Henrique Machado de; Bataglion, César; Magalhães, Denildo de

    2009-01-01

    The esthetics and functional integrity of the periodontal tissue may be compromised by dental loss. Immediate implants became a viable option to maintain the periodontal architecture because of their anatomic compatibility with the dental socket and the possibility of eliminating local contamination. This article describes the procedure of immediate implant placement in the anterior maxilla replacing teeth with chronic periapical lesions, which were condemned due to endodontic lesions persisting after failed endodontic treatment and endodontic surgery, and discusses the relationship between the procedure and periapical lesions. Surgical removal of hopeless teeth 11, 12 and 21 was performed conservatively in such a way to preserve the anatomy and gingival esthetics. A second surgical access was gained at the apical level, allowing the debridement of the surgical chamber for elimination of the periapical lesion, visual orientation for setting of the implants and filling of the surgical chamber with xenogenous bovine bone graft. After this procedure, the bone chamber was covered with an absorbent membrane and the healing screws were positioned on the implants. Later, a provisional partial removable denture was installed and the implants were inserted after 6 months. After 3 years of rehabilitation, the implants present satisfactory functional and esthetic conditions, suggesting that immediate implant placement combined with guided bone regeneration may be indicated for replacing teeth lost due to chronic periapical lesions with endodontic failure history in the anterior maxilla.

  19. Repair of experimental plaque-induced periodontal disease in dogs.

    PubMed

    Shoukry, M; Ben Ali, L; Abdel Naby, M; Soliman, A

    2007-09-01

    Forty mongrel dogs were used in this study for induction of periodontal disease by placing subgingival silk ligatures affecting maxillary and mandibular premolar teeth during a 12-month period. Experimental premolar teeth received monthly clinical, radiographic, and histometric/pathologic assessments. The results demonstrated significant increases in scores and values of periodontal disease parameters associated with variable degrees of alveolar bone loss. The experimental maxillary premolar teeth exhibited more severe and rapid rates of periodontal disease compared with mandibular premolar teeth. Histometric analysis showed significant reduction in free and attached gingiva of the experimental teeth. Histopathological examination of buccolingual sections from experimental premolar teeth showed the presence of rete pegs within the sulcular epithelium with acanthosis and erosive changes, widening of the periodontal ligament, and alveolar bone resorption. Various methods for periodontal repair were studied in 194 experimental premolar teeth exhibiting different degrees of periodontal disease. The treatment plan comprised non-surgical (teeth scaling, root planing, and oral hygiene) and surgical methods (closed gingival curettage, modified Widman flap, and reconstructive surgery using autogenous bone marrow graft and canine amniotic membrane). The initial non-surgical treatment resulted in a periodontal recovery rate of 37.6% and was found effective for treatment of early periodontal disease based on resolution of gingivitis and reduction of periodontal probing depths. Surgical treatment by closed gingival curettage to eliminate the diseased pocket lining resulted in a recovery rate of 48.8% and proved effective in substantially reducing deep periodontal pockets. Open root planing following flap elevation resulted in a recovery rate of 85.4% and was effective for deep and refractory periodontal pockets. Autogenous bone graft implantation combined with canine amniotic membrane as a biodegradable membrane was used in 18 premolar teeth and failed to improve advanced furcation defects in most teeth.

  20. Augmented corticotomy-assisted surgical orthodontics decompensates lower incisors in Class III malocclusion patients.

    PubMed

    Wang, Bo; Shen, Guofang; Fang, Bing; Yu, Hongbo; Wu, Yong; Sun, Liangyan

    2014-03-01

    To quantitatively evaluate lower incisor decompensation and the surrounding periodontal region after augmented corticotomy-assisted surgical orthodontics in patients with Class III malocclusion. This prospective study enrolled patients with severe Class III malocclusion who underwent augmented corticotomy in the lower anterior region before orthodontic surgery. Cone-beam computed tomograms and lateral cephalograms were obtained before treatment (T0), after presurgical orthodontic treatment (T1), and at removal of the orthodontic surgical appliances (T2). Repeated measures analysis of variance was used to compare variables at each time point: root length (RL), anterior vertical alveolar bone level at the labial side (AVBL), posterior vertical alveolar bone level at the lingual side (PVBL), labial alveolar bone thickness at the apex (LA), lingual alveolar bone thickness at the apex (LP), and angle of the incisor to the mandibular plane (L1-MP). In the 8 subjects studied, RL was maintained from T0 to T2 (P > .05), whereas AVBL and PVBL increased from T0 to T1 (P < .05) and then decreased from T1 to T2 (P < .05). LA and L1-MP increased from T0 to T1 (P < .001) but remained steady from T1 to T2 (P > .05). LP decreased from T0 to T1 (P < .05) but increased from T1 to T2 (P < .05) with no further change. Augmented corticotomy-assisted surgical orthodontics can achieve adequate tooth decompensation with minimal periodontal side-effects in the lower anterior region in patients with Class III malocclusion. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  1. Osseodensification for enhancement of spinal surgical hardware fixation.

    PubMed

    Lopez, Christopher D; Alifarag, Adham M; Torroni, Andrea; Tovar, Nick; Diaz-Siso, J Rodrigo; Witek, Lukasz; Rodriguez, Eduardo D; Coelho, Paulo G

    2017-05-01

    Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4mm diameter×10mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p<0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p<0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Osseodensification for enhancement of spinal surgical hardware fixation

    PubMed Central

    Lopez, Christopher D.; Alifarag, Adham M.; Torroni, Andrea; Tovar, Nick; Diaz-Siso, J. Rodrigo; Witek, Lukasz; Rodriguez, Eduardo D.; Coelho, Paulo G.

    2017-01-01

    Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65 kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4 mm diameter×10 mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p < 0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p < 0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation. PMID:28113132

  3. Tunnel widening prevention with the allo-Achilles tendon graft in anterior cruciate ligament reconstruction: Surgical tips and short term followup

    PubMed Central

    Suh, Dong Won; Han, Seung Beom; Yeo, Woo Jin; Lee, Won Hee; Kwon, Jae Ho; Kyung, Bong Soo

    2017-01-01

    Background: Tunnel widening (TW) after anterior cruciate ligament (ACL) reconstruction can be a serious complication, and there is controversy over how to prevent it. This study aimed to suggest surgical approaches to prevent TW using an allo-Achilles tendon graft, and then to evaluate TW after these surgical tips were applied. Materials and Methods: Sixty two patients underwent ACL reconstruction with an allo-Achilles tendon graft. Four surgical approaches were used: Making a tibial tunnel by bone impaction, intraarticular reamer application, bone portion application for the femoral tunnel, and an additional bone plug application for the tibial tunnel. After more than 1-year, followup radiographs including anteroposterior and lateral views were taken in 29 patients encompassing thirty knees. The diameter of the tunnels at postoperation day 1 (POD1) and at followup was measured and compared. Results: In 18 knees (60%), there were no visible femoral tunnel margins on the radiographs at POD1 or followup. In the other 12 cases, which had visible femoral tunnel margins on followup radiographs, the mean femoral tunnel diameter was 8.6 mm. In the tibial tunnel, the mean diameters did not increase on all three levels (proximal, middle, and distal), and there was no statistically significant difference between the diameters at POD1 and followup. Conclusion: The suggested tips for surgery involving an allo-Achilles tendon graft can effectively prevent TW after ACL reconstruction according to this case series. These surgical tips can prevent TW. PMID:28400663

  4. Numerical simulation on the adaptation of forms in trabecular bone to mechanical disuse and basic multi-cellular unit activation threshold at menopause

    NASA Astrophysics Data System (ADS)

    Gong, He; Fan, Yubo; Zhang, Ming

    2008-04-01

    The objective of this paper is to identify the effects of mechanical disuse and basic multi-cellular unit (BMU) activation threshold on the form of trabecular bone during menopause. A bone adaptation model with mechanical- biological factors at BMU level was integrated with finite element analysis to simulate the changes of trabecular bone structure during menopause. Mechanical disuse and changes in the BMU activation threshold were applied to the model for the period from 4 years before to 4 years after menopause. The changes in bone volume fraction, trabecular thickness and fractal dimension of the trabecular structures were used to quantify the changes of trabecular bone in three different cases associated with mechanical disuse and BMU activation threshold. It was found that the changes in the simulated bone volume fraction were highly correlated and consistent with clinical data, and that the trabecular thickness reduced significantly during menopause and was highly linearly correlated with the bone volume fraction, and that the change trend of fractal dimension of the simulated trabecular structure was in correspondence with clinical observations. The numerical simulation in this paper may help to better understand the relationship between the bone morphology and the mechanical, as well as biological environment; and can provide a quantitative computational model and methodology for the numerical simulation of the bone structural morphological changes caused by the mechanical environment, and/or the biological environment.

  5. Learning Curves of Virtual Mastoidectomy in Distributed and Massed Practice.

    PubMed

    Andersen, Steven Arild Wuyts; Konge, Lars; Cayé-Thomasen, Per; Sørensen, Mads Sølvsten

    2015-10-01

    Repeated and deliberate practice is crucial in surgical skills training, and virtual reality (VR) simulation can provide self-directed training of basic surgical skills to meet the individual needs of the trainee. Assessment of the learning curves of surgical procedures is pivotal in understanding skills acquisition and best-practice implementation and organization of training. To explore the learning curves of VR simulation training of mastoidectomy and the effects of different practice sequences with the aim of proposing the optimal organization of training. A prospective trial with a 2 × 2 design was conducted at an academic teaching hospital. Participants included 43 novice medical students. Of these, 21 students completed time-distributed practice from October 14 to November 29, 2013, and a separate group of 19 students completed massed practice on May 16, 17, or 18, 2014. Data analysis was performed from June 6, 2014, to March 3, 2015. Participants performed 12 repeated virtual mastoidectomies using a temporal bone surgical simulator in either a distributed (practice blocks spaced in time) or massed (all practice in 1 day) training program with randomization for simulator-integrated tutoring during the first 5 sessions. Performance was assessed using a modified Welling Scale for final product analysis by 2 blinded senior otologists. Compared with the 19 students in the massed practice group, the 21 students in the distributed practice group were older (mean age, 25.1 years), more often male (15 [62%]), and had slightly higher mean gaming frequency (2.3 on a 1-5 Likert scale). Learning curves were established and distributed practice was found to be superior to massed practice, reported as mean end score (95% CI) of 15.7 (14.4-17.0) in distributed practice vs. 13.0 (11.9-14.1) with massed practice (P = .002). Simulator-integrated tutoring accelerated the initial performance, with mean score for tutored sessions of 14.6 (13.9-15.2) vs. 13.4 (12.8-14.0) for corresponding nontutored sessions (P < .01) but at the cost of a drop in performance once tutoring ceased. The performance drop was less with distributed practice, suggesting a protective effect when acquired skills were consolidated over time. The mean performance of the nontutored participants in the distributed practice group plateaued on a score of 16.0 (15.3-16.7) at approximately the ninth repetition, but the individual learning curves were highly variable. Novices can acquire basic mastoidectomy competencies with self-directed VR simulation training. Training should be organized with distributed practice, and simulator-integrated tutoring can be useful to accelerate the initial learning curve. Practice should be deliberate and toward a standard set level of proficiency that remains to be defined rather than toward the mean learning curve plateau.

  6. An Unusual Localization of Intraosseous Schwannoma: The Hamate Bone.

    PubMed

    Gurkan, Volkan; Sonmez, Cavide; Aralasmak, Ayse; Yildiz, Fatih; Erdogan, Ozgur

    2017-01-11

    Intraosseous schwannoma of the hamate bone presented in this case is a very rare benign tumor, and its diagnosis combined with clinical, imaging and needle biopsy is important to guide further therapy. The diagnosis of schwannoma of the hamate was proved histologically following its surgical treatment by curettage.

  7. 21 CFR 882.4275 - Dowel cutting instrument.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Dowel cutting instrument. 882.4275 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4275 Dowel cutting instrument. (a) Identification. A dowel cutting instrument is a device used to cut dowels of bone for bone grafting. (b...

  8. CAD-CAM-generated hydroxyapatite scaffold to replace the mandibular condyle in sheep: preliminary results.

    PubMed

    Ciocca, Leonardo; Donati, Davide; Fantini, Massimiliano; Landi, Elena; Piattelli, Adriano; Iezzi, Giovanna; Tampieri, Anna; Spadari, Alessandro; Romagnoli, Noemi; Scotti, Roberto

    2013-08-01

    In this study, rapid CAD-CAM prototyping of pure hydroxyapatite to replace temporomandibular joint condyles was tested in sheep. Three adult animals were implanted with CAD-CAM-designed porous hydroxyapatite scaffolds as condyle substitutes. The desired scaffold shape was achieved by subtractive automated milling machining (block reduction). Custom-made surgical guides were created by direct metal laser sintering and were used to export the virtual planning of the bone cut lines into the surgical environment. Using the same technique, fixation plates were created and applied to the scaffold pre-operatively to firmly secure the condyles to the bone and to assure primary stability of the hydroxyapatite scaffolds during masticatory function. Four months post-surgery, the sheep were sacrificed. The hydroxyapatite scaffolds were explanted, and histological specimens were prepared. Different histological tissues penetrating the scaffold macropores, the sequence of bone remodeling, new apposition of bone and/or cartilage as a consequence of the different functional anatomic role, and osseointegration at the interface between the scaffold and bone were documented. This animal model was found to be appropriate for testing CAD-CAM customization and the biomechanical properties of porous, pure hydroxyapatite scaffolds used as joint prostheses.

  9. Developing Customized Dental Miniscrew Surgical Template from Thermoplastic Polymer Material Using Image Superimposition, CAD System, and 3D Printing

    PubMed Central

    Yu, Jian-Hong; Lo, Lun-Jou; Hsu, Pin-Hsin

    2017-01-01

    This study integrates cone-beam computed tomography (CBCT)/laser scan image superposition, computer-aided design (CAD), and 3D printing (3DP) to develop a technology for producing customized dental (orthodontic) miniscrew surgical templates using polymer material. Maxillary bone solid models with the bone and teeth reconstructed using CBCT images and teeth and mucosa outer profile acquired using laser scanning were superimposed to allow miniscrew visual insertion planning and permit surgical template fabrication. The customized surgical template CAD model was fabricated offset based on the teeth/mucosa/bracket contour profiles in the superimposition model and exported to duplicate the plastic template using the 3DP technique and polymer material. An anterior retraction and intrusion clinical test for the maxillary canines/incisors showed that two miniscrews were placed safely and did not produce inflammation or other discomfort symptoms one week after surgery. The fitness between the mucosa and template indicated that the average gap sizes were found smaller than 0.5 mm and confirmed that the surgical template presented good holding power and well-fitting adaption. This study addressed integrating CBCT and laser scan image superposition; CAD and 3DP techniques can be applied to fabricate an accurate customized surgical template for dental orthodontic miniscrews. PMID:28280726

  10. Computer-designed surgical guide template compared with free-hand operation for mesiodens extraction in premaxilla using “trapdoor” method

    PubMed Central

    Hu, Ying Kai; Xie, Qian Yang; Yang, Chi; Xu, Guang Zhou

    2017-01-01

    Abstract The aim of this study was to introduce a novel method of mesiodens extraction using a vascularized pedicled bone flap by piezosurgery and to compare the differences between a computer-aided design surgical guide template and free-hand operation. A total of 8 patients with mesiodens, 4 with a surgical guide (group I), and 4 without it (group II) were included in the study. The surgical design was to construct a trapdoor pedicle on the superior mucoperiosteal attachment with application of piezosurgery. The bone lid was repositioned after mesiodens extraction. Group I patients underwent surgeries based on the preoperative planning with surgical guide templates, while group II patients underwent free-hand operation. The outcome variables were success rate, intraoperative time, anterior nasal spine (ANS) position, changes of nasolabial angle (NLA), and major complications. Data from the 2 groups were compared by SPSS 17.0, using Wilcoxon test. The operative time was significantly shorter in group I patients. All the mesiodentes were extracted successfully and no obvious differences of preoperative and postoperative ANS position and NLA value were found in both groups. The patients were all recovered uneventfully. Surgical guide templates can enhance clinical accuracy and reduce operative time by facilitating accurate osteotomies. PMID:28658139

  11. The role of simulation in the development of technical competence during surgical training: a literature review

    PubMed Central

    2013-01-01

    Objectives To establish the current state of knowledge on the effect of surgical simulation on the development of technical competence during surgical training. Methods Using a defined search strategy, the medical and educational literature was searched to identify empirical research that uses simulation as an educational intervention with surgical trainees. Included studies were analysed according to guidelines adapted from a Best Evidence in Medical Education review. Results A total of 32 studies were analysed, across 5 main categories of surgical simulation technique - use of bench models and box trainers (9 studies); Virtual Reality (14 studies); human cadavers (4 studies); animal models (2 studies) and robotics (3 studies). An improvement in technical skill was seen within the simulated environment across all five categories. This improvement was seen to transfer to the real patient in the operating room in all categories except the use of animals. Conclusions Based on current evidence, surgical trainees should be confident in the effects of using simulation, and should have access to formal, structured simulation as part of their training. Surgical simulation should incorporate the use of bench models and box trainers, with the use of Virtual Reality where resources allow. Alternatives to cadaveric and animal models should be considered due to the ethical and moral issues surrounding their use, and due to their equivalency with other simulation techniques. However, any use of surgical simulation must be tailored to the individual needs of trainees, and should be accompanied by feedback from expert tutors.

  12. Pre-surgical CT-assessment of neurogenic myositis ossificans of the hip and risk factors of recurrence: a series of 101 consecutive patients.

    PubMed

    Law-Ye, Bruno; Hangard, Chloé; Felter, Adrien; Safa, Dominique; Denormandie, Philippe; Genet, François; Carlier, Robert-Yves

    2016-10-18

    Neurogenic Myositis Ossificans (NMO) is a rare disabling pathology characterized by peri-articular heterotopic ossifications following severe peripheral or central nervous system injuries. It results in ankylosis and vessels or nerves compressions. Our study aimed to describe the pre-operative findings of patients with NMO of the hip using biphasic computerized tomography (CT). Between 2006 and 2012, we retrospectively analyzed 101 consecutive patients with hip NMO. We analyzed all CTs and surgical reports following a standardized grid depicting the osteoma and its relations with joint capsule, vessels and nerves and bone mineralization. We studied surgical complications and recurrence during follow-up. Chi2-test and Fischer's test were performed to compare qualitative values with respectively normal and non-normal distribution. Quantitative values were analyzed with a one factor analysis of variance (ANOVA) test. Agreement between pre-surgical CT and surgical observations was evaluated with Cohen's kappa test. Correlation between pre-operative CT and surgical findings was excellent regarding relationships with vessels (0,82) and was good concerning relationships with sciatic nerves (0.62) and with joint capsule (0.68). Close contact or disruption of joint capsule (p = 0.005), joint space narrowing (p = 0.007) and bone demineralization (p < 0.001) were correlated with NMO recurrence. Biphasic enhanced-CT allows pre-operative assessment of NMO with good correlation to surgical observations and helps prevent surgical complications.

  13. A Study to Determine the Best Method of Caring for Certain Short-Stay Surgical Patients at Reynolds Army Community Hospital

    DTIC Science & Technology

    1988-09-01

    Perineoplasty Vaginal cyst, cautery Vaginal web, excision Surgical Patients 95 ORTHOPEDIC Arthrodesis of phalanges Arthroscopy Bone biopsy Bunionectomy...Manipulation of shoulder, knee, or hip Mass excision with scar revision Meniscectomy (if done through arthroscopy ) Metatarsal head, excision unilateral

  14. Parameters affecting mechanical and thermal responses in bone drilling: A review.

    PubMed

    Lee, JuEun; Chavez, Craig L; Park, Joorok

    2018-04-11

    Surgical bone drilling is performed variously to correct bone fractures, install prosthetics, or for therapeutic treatment. The primary concern in bone drilling is to extract donor bone sections and create receiving holes without damaging the bone tissue either mechanically or thermally. We review current results from experimental and theoretical studies to investigate the parameters related to such effects. This leads to a comprehensive understanding of the mechanical and thermal aspects of bone drilling to reduce their unwanted complications. This review examines the important bone-drilling parameters of bone structure, drill-bit geometry, operating conditions, and material evacuation, and considers the current techniques used in bone drilling. We then analyze the associated mechanical and thermal effects and their contributions to bone-drilling performance. In this review, we identify a favorable range for each parameter to reduce unwanted complications due to mechanical or thermal effects. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. Validating in vivo Raman spectroscopy of bone in human subjects

    NASA Astrophysics Data System (ADS)

    Esmonde-White, Francis W. L.; Morris, Michael D.

    2013-03-01

    Raman spectroscopy can non-destructively measure properties of bone related to mineral density, mineral composition, and collagen composition. Bone properties can be measured through the skin in animal and human subjects, but correlations between the transcutaneous and exposed bone measurements have only been reported for human cadavers. In this study, we examine human subjects to collect measurements transcutaneously, on surgically exposed bone, and on recovered bone fragments. This data will be used to demonstrate in vivo feasibility and to compare transcutaneous and exposed Raman spectroscopy of bone. A commercially available Raman spectrograph and optical probe operating at 785 nm excitation are used for the in vivo measurements. Requirements for applying Raman spectroscopy during a surgery are also discussed.

  16. The Proposal and Early Results of Capitate Forage as a New Treatment Method for Kienböck's Disease.

    PubMed

    Bekler, Halil Ibrahim; Erdag, Yiğit; Gumustas, Seyit Ali; Pehlivanoglu, Gökhan

    2013-12-01

    Kienböck's disease is a type of avascular necrosis which disrupts the biomechanics of the wrist as a result of the changes it creates in the lunate bone. Its treatment generally consists of osteotomies intended to relieve the pressure on the bone, pedicle bone grafting applications aiming to increase bone blood supply, and salvage procedures. Capitate forage is a safe and simple-to-apply surgical treatment method which is intended to enhance neovascularization of the lunate much like a radius osteotomy or core decompression.

  17. Effects of bovine lactoferrin in surgically created bone defects on bone regeneration around implants.

    PubMed

    Görmez, Ulaş; Kürkcü, Mehmet; E Benlidayi, Mehmet; Ulubayram, Kezban; Sertdemir, Yaşar; Dağlioğlu, Kenan

    2015-03-01

    The aim of this experimental study was to evaluate the effect of bovine lactoferrin (bLF)-loaded gelatin microspheres (GM) used in combination with anorganic bovine bone on bone regeneration in surgically created bone defects around tooth implants. Twenty-four uniform bone defects were created in the frontal bone via an extraoral approach in 12 domestic pigs. Twenty-four implants were placed at the center of the defects. In eight animals one of these defects was filled with 0.3 mL anorganic bovine bone while the other was left empty. In four animals, all defects were filled with 3 mg/defect bLF-loaded GM and anorganic bovine bone. All the defects were covered with collagen membranes. All animals were sacrificed after 10 weeks of healing, and the implants with the surrounding bone defects were removed en bloc. Undecalcified sections were prepared for histomorphometric analysis. The mean total area of hard tissue was 26.9 ± 6.0% in the empty defect group, 31.8 ± 8.4% in the graft group, and 47.6 ± 5.0% in the lactoferrin group (P < 0.001). The mean area of newly formed bone was 26.9 ± 6.0% in the empty defect group, 22.4 ± 8.2% in the graft group, and 46.1 ± 5.1% in the lactoferrin group (P < 0.001). The mean residual graft area was 9.4 ± 3.2% in the graft group and 1.5 ± 0.6% in the lactoferrin group (P < 0.001). The mean proportion of bone-implant contact in the defect region was 21.9 ± 8.4% in the empty defect group, 26.9 ± 10.1% in the graft group and 29.9 ± 10.3% in the lactoferrin group (P = 0.143). These data indicate that a combination of 3 mg bLF-loaded GM and bovine-derived HA promotes bone regeneration in defects around implants.

  18. Adjustable selective maxillary expansion combined with maxillomandibular surgery: A case report.

    PubMed

    Leyder, Patrick; Altounian, Gérard; Chardain, Jacques; Quilichini, Julien

    2015-09-01

    Surgically assisted rapid maxillary expansion (SARME) is usually considered the gold standard for maxillary transverse expansion in adults. However, a second surgical procedure is needed in cases of associated sagittal or vertical discrepancies. We describe the use of two new innovative devices for the correction of discrepancies in all dimensions during a single surgical procedure, thus reducing treatment duration. We report the case of a 21-year-old female patient, referred to our department for skeletal Class III malocclusion associated with right-side laterognathism and transverse maxillary deficiency. The patient underwent one-stage surgery, using sliding osteosynthesis plates and an adjustable bone-borne distractor. Pre-surgical orthodontics consisted in leveling and aligning the mandibular arch; maxillary leveling was initiated 3 months before surgery. Postoperative palatal distraction combined with orthodontic finishing enabled complete correction of dental and bony discrepancies after 3 months. In our experience, treatment of transverse, sagittal and vertical discrepancies has been possible in a single surgical procedure, using two innovative techniques: sliding osteosynthesis and an adjustable bone distractor. Two years post-surgery, the correction is stable in all dimensions. Copyright © 2015. Published by Elsevier Masson SAS.

  19. [Use of free vascularized fibular graft flap in the treatment of large bone defects after limb injury].

    PubMed

    Bumbasirević, Marko Z; Lesić, Aleksandar R; Atkinson, Henry Dushan Edward; Tulić, Goran C

    2013-01-01

    Free vascularized fibular graft is of the greatest importance in the orthopaedics and trauma. Bone, skeletal defects due to the trauma, infections and congenital anomalies could be successfully solved by the free vascularized fibular grafts. In this article the main anatomical data of fibular graft, surgical techniques, indications for the FVFG in the treatment of trauma caused bone defects or its complications -sequels are described.

  20. [Surgical treatment of patients with exudative otitis media].

    PubMed

    Dmitriev, N S; Mileshina, N A

    2003-01-01

    The article concerns peculiarities of surgery for chronic exudative otitis media (CEOM). The significance of miringotomy, tympanostomy, tympanotomy and tympanoantrotomy is demonstrated. The experience of the authors in surgical treatment and postoperative management of CEOM is reviewed. Of primary importance is valid selection of patients for each operation and choice of ventilatory tubes depending on the disease stage. Incidence rate and causes of recurrences in respect to the patients' age are presented and the role of follow-up in prevention of CEOM recurrences is shown. Use of temporal bone computed tomography in CEOM is specified. Key words: exudative otitis media, tympanostomy, ventilation tubes, CT of the temporal bone.

  1. Custom Titanium Ridge Augmentation Matrix (CTRAM): A Case Report.

    PubMed

    Connors, Christopher A; Liacouras, Peter C; Grant, Gerald T

    2016-01-01

    This is a case report of a custom titanium ridge augmentation matrix (CTRAM). Using cone beam computed tomography (CBCT), a custom titanium space-maintaining device was developed. Alveolar ridges were virtually augmented, a matrix was virtually designed, and the CTRAM was additively manufactured with titanium (Ti6Al4V). Two cases are presented that resulted in sufficient increased horizontal bone volume with successful dental implant placement. The CTRAM design allows for preoperative planning for increasing alveolar ridge dimensions to support dental implants, reduces surgical time, and prevents the need for a second surgical site to gain sufficient alveolar ridge bone volume for dental implant therapy.

  2. Prevalence and estimated incidence of blood-borne viral pathogen infection in organ and tissue donors from northern Alberta.

    PubMed

    Zahariadis, G; Plitt, S S; O'Brien, S; Yi, Q-L; Fan, W; Preiksaitis, J K

    2007-01-01

    To determine the potential safety benefit of introducing nucleic acid testing (NAT) in tissue and organ donors, the risk of virus transmission was examined in a Canadian population. Anonymous data on Northern Alberta tissue and organ donors from 1998 to 2004 were used to determine the seroprevalence and estimate the seroincidence and residual risk of HIV, HBV, HCV and HTLV infection. Of the 3372 donors identified, 71.1% were surgical bone, 13.2% were living organ and 15.6% were deceased organ/tissue donors. Seroprevalence was: HIV 0.00%, HBV 0.09%, HCV 0.48% and HTLV 0.03%. Incidence (/100,000 p-yrs) and residual risks (/100,000 donors) could only be estimated for HBV (24.2 and 3.9) and HCV (11.2 and 2.2). Risk estimates were higher for deceased donors than surgical bone donors. HCV had the highest prevalence and HBV had the highest estimated incidence. HIV and HTLV risks were extremely low precluding accurate quantification. In this region of low overall viral prevalence, HCV NAT would be most effective in deceased organ donors. In surgical bone donors the cost of implementing NAT is high without significant added safety benefit.

  3. [Autotransplantation of a maxillary incisor and orthodontic care: a case study].

    PubMed

    Charpentier, Valentine; Makaremi, Masrour; Brondeau, François de

    2017-12-01

    Severely impacted teeth with atypical root anatomy do not respond well to orthodontic traction after surgical exposure. Consequently, they are often removed, but replacing them with dental prostheses can prove difficult in patients who are still growing. Thus, autotransplantation seems to be the only way to preserve a natural tooth and the alveolar bone. An upper central incisor impacted in the region of the nasal cavities with an open apex was diagnosed in an 8.5-year-old female patient. The tooth displayed a curved root pressed against the maxillary cortical bone preventing orthodontic traction treatment. Through this clinical case involving autotransplantation of a maxillary incisor report and a review of the literature, this article explores the indications and exposes the different stages of this orthodontic-surgical protocol. In this case, autotransplantation enabled restoration of maxillary arch continuity. After two years of orthodontic treatment, the bone reconstruction of the extraction site was very satisfactory. The benefits of this technique and the precautions to be taken are discussed as well as the various protocols. The increasing success rate of this surgical procedure makes it possible to consider it as a protocol for the future. © EDP Sciences, SFODF, 2017.

  4. Implementing Capsule Representation in a Total Hip Dislocation Finite Element Model

    PubMed Central

    Stewart, Kristofer J; Pedersen, Douglas R; Callaghan, John J; Brown, Thomas D

    2004-01-01

    Previously validated hardware-only finite element models of THA dislocation have clarified how various component design and surgical placement variables contribute to resisting the propensity for implant dislocation. This body of work has now been enhanced with the incorporation of experimentally based capsule representation, and with anatomic bone structures. The current form of this finite element model provides for large deformation multi-body contact (including capsule wrap-around on bone and/or implant), large displacement interfacial sliding, and large deformation (hyperelastic) capsule representation. In addition, the modular nature of this model now allows for rapid incorporation of current or future total hip implant designs, accepts complex multi-axial physiologic motion inputs, and outputs case-specific component/bone/soft-tissue impingement events. This soft-tissue-augmented finite element model is being used to investigate the performance of various implant designs for a range of clinically-representative soft tissue integrities and surgical techniques. Preliminary results show that capsule enhancement makes a substantial difference in stability, compared to an otherwise identical hardware-only model. This model is intended to help put implant design and surgical technique decisions on a firmer scientific basis, in terms of reducing the likelihood of dislocation. PMID:15296198

  5. Design of a surgical instrument for removing bone to provide screw access to a spinal fusion cage.

    PubMed

    Jabbary Aslani, F; Hukins, D W L; Shepherd, D E T; Parry, J J; Fennell, A J; Lambell, S

    2012-01-01

    A surgical instrument to aid implantation of a range of lumbar spinal fusion cages has been developed. Once the cage is in position, the entrance to screw holes is partially blocked by the edge of the vertebral body. In order to insert fixation screws to secure the cage between the vertebrae, some part of the blocking edge has to be removed. Rongeurs are currently being used, but they can be time consuming and have the disadvantage that they may remove more bone than is necessary and may cause damage to the fusion cage if not used with care. In addition, access around some of the screw holes may be difficult. The aim of this instrument was to overcome these shortcomings. This paper describes the design of a surgical instrument for cutting edges from vertebral bodies. The development and evaluation of concept designs are presented and discussed. Potential risks were considered and modifications were performed on the selected concept. Functional prototypes were manufactured and tested on sheep lumbar vertebrae. The results showed that the newly designed cutting instrument functions as required and removes the required amount of bone from the vertebral body edge.

  6. Comparison of titanium and Robinson stainless steel stapes piston prostheses.

    PubMed

    Lippy, William H; Burkey, John M; Schuring, Arnold G; Berenholz, Leonard P

    2005-09-01

    Although stainless steel stapes prostheses have generally been considered magnetic resonance imaging safe, there is concern that this may change with the development of more powerful imaging systems. The objective of the study was to determine whether a titanium piston stapes prosthesis would be audiometrically and surgically equivalent to a Robinson stainless steel piston for stapedectomy. Retrospective chart review. Private otology practice. In all, 50 patients underwent stapedectomy with a Gyrus titanium piston prosthesis. These patients were matched on the basis of age and preoperative bone-conduction scores with patients who underwent stapedectomy with a Robinson stainless steel piston prosthesis. Audiometric results are analyzed, and surgical complications noted. There was no significant difference between groups in hearing improvement or postoperative air-bone gap. The mean four-frequency hearing improvement was 27.7 dB for the stainless steel group and 27.8 dB for the titanium group. The mean postoperative air-bone gap was 2.65 dB for the stainless steel group and 2.60 for the titanium group. Neither group had a surgical complication. The titanium stapes prosthesis is a good alternative to a stainless steel prosthesis.

  7. [Applicational evaluation of split tooth extractions of upper molars using piezosurgery].

    PubMed

    Li, D; Guo, C B; Liu, Y; Wang, E B

    2016-02-18

    To evaluate the efficacy of Piezosurgery in split teeth extractions. A single-center, randomized, split-mouth study was performed using a consecutive serious of unrelated healthy patients attending the departing of oral and maxillofacial surgery, Peking University School and Hospital of Stomatology. 40 patients were selected for extraction of maxillary molars without reservation value,splitting or nonvital teeth. They were divided into control (20 patients) and test groups (20 patients) randomly. Surgical treatments for both groups were under local anesthesia. Molar teeth of control group were extracted by common equipments like dental elevators, chisels, forceps, etc. While molar teeth of experimental group were extracted by Piezosurgery, aided with the use of common equipments if needed. Then we compared the duration of surgery, frequency of the usage of chisels, expansion of postoperative bony socket surgical discomfort and postoperative pain between two groups. The average of operation time was (629.5±171.0) s in control group and (456.0±337.2) s in test group. The buccal alveolar bone reduced (1.07±0.64) mm in control group and (1.49±0.61) mm in test group. There was a significant difference between the two groups (P<0.05). The duration of surgery for experimental group was significantly longer than that of the control group, but the change of buccal alveolar bone was lower than the control group. For visual analogue scale (VAS) value of surgical discomfort, expansion of postoperative bony socket and the operative fear rate, there were no significant difference between the two groups (P>0.05). Piezosugery can be better to preserve alveolar bone, reduce trauma and patient's fear. Application of the piezosugery reflect the characteristics of minimally invasive extraction, which has the value of promotion. The Piezosurgery technique have the advantage of reducing change of buccal alveolar bone during the surgery, but a longer surgical time was required when compared with the conventional technique. VAS value of surgical discomfort, expansion of postoperative bony socket and the operative fear rate, there were no significant difference. Minimally invasive tooth extraction technique has good clinical results and high satisfaction. Piezosurgery proved its worth as the instrument adapted to limiting the destruction of bone tissue.

  8. [Applicational evaluation of split tooth extractions of upper molars using piezosurgery].

    PubMed

    Li, D; Guo, C B; Liu, Y; Wang, E B

    2016-08-18

    To evaluate the efficacy of Piezosurgery in split teeth extractions. A single-center, randomized, split-mouth study was performed using a consecutive serious of unrelated healthy patients attending the departing of oral and maxillofacial surgery, Peking University School and Hospital of Stomatology. 40 patients were selected for extraction of maxillary molars without reservation value,splitting or nonvital teeth. They were divided into control (20 patients) and test groups (20 patients) randomly. Surgical treatments for both groups were under local anesthesia. Molar teeth of control group were extracted by common equipments like dental elevators, chisels, forceps, etc. While molar teeth of experimental group were extracted by Piezosurgery, aided with the use of common equipments if needed. Then we compared the duration of surgery, frequency of the usage of chisels, expansion of postoperative bony socket surgical discomfort and postoperative pain between two groups. The average of operation time was (629.5±171.0) s in control group and (456.0±337.2) s in test group. The buccal alveolar bone reduced (1.07±0.64) mm in control group and (1.49±0.61) mm in test group. There was a significant difference between the two groups (P<0.05). The duration of surgery for experimental group was significantly longer than that of the control group, but the change of buccal alveolar bone was lower than the control group. For visual analogue scale (VAS) value of surgical discomfort, expansion of postoperative bony socket and the operative fear rate, there were no significant difference between the two groups (P>0.05). Piezosugery can be better to preserve alveolar bone, reduce trauma and patient's fear. Application of the piezosugery reflect the characteristics of minimally invasive extraction, which has the value of promotion. The Piezosurgery technique have the advantage of reducing change of buccal alveolar bone during the surgery, but a longer surgical time was required when compared with the conventional technique. VAS value of surgical discomfort, expansion of postoperative bony socket and the operative fear rate, there were no significant difference. Minimally invasive tooth extraction technique has good clinical results and high satisfaction. Piezosurgery proved its worth as the instrument adapted to limiting the destruction of bone tissue.

  9. Modeling of Tool-Tissue Interactions for Computer-Based Surgical Simulation: A Literature Review

    PubMed Central

    Misra, Sarthak; Ramesh, K. T.; Okamura, Allison M.

    2009-01-01

    Surgical simulators present a safe and potentially effective method for surgical training, and can also be used in robot-assisted surgery for pre- and intra-operative planning. Accurate modeling of the interaction between surgical instruments and organs has been recognized as a key requirement in the development of high-fidelity surgical simulators. Researchers have attempted to model tool-tissue interactions in a wide variety of ways, which can be broadly classified as (1) linear elasticity-based, (2) nonlinear (hyperelastic) elasticity-based finite element (FE) methods, and (3) other techniques that not based on FE methods or continuum mechanics. Realistic modeling of organ deformation requires populating the model with real tissue data (which are difficult to acquire in vivo) and simulating organ response in real time (which is computationally expensive). Further, it is challenging to account for connective tissue supporting the organ, friction, and topological changes resulting from tool-tissue interactions during invasive surgical procedures. Overcoming such obstacles will not only help us to model tool-tissue interactions in real time, but also enable realistic force feedback to the user during surgical simulation. This review paper classifies the existing research on tool-tissue interactions for surgical simulators specifically based on the modeling techniques employed and the kind of surgical operation being simulated, in order to inform and motivate future research on improved tool-tissue interaction models. PMID:20119508

  10. The ablation threshold of Er;Cr:YSGG laser radiation in bone tissue

    NASA Astrophysics Data System (ADS)

    Benetti, Carolina; Zezell, Denise Maria

    2015-06-01

    In laser cut clinical applications, the use of energy densities lower than the ablation threshold causes increase of temperature of the irradiated tissue, which might result in an irreversible thermal damage. Hence, knowing the ablation threshold is crucial for insuring the safety of these procedures. The aim of this study was to determine the ablation threshold of the Er,Cr:YSGG laser in bone tissue. Bone pieces from jaws of New Zealand rabbits were cut as blocks of 5 mm × 8 mm and polished with sandpaper. The Er,Cr:YSGG laser used in this study had wavelength of 2780 nm, 20 Hz of frequency, and the irradiation condition was chosen so as to simulate the irradiation during a surgical procedure. The laser irradiation was performed with 12 different values of laser energy densities, between 3 J/cm2 and 42 J/cm2, during 3 seconds, resulting in the overlap of 60 pulses. This process was repeated in each sample, for all laser energy densities. After irradiation, the samples were analyzed by scanning electron microscope (SEM), and it was measured the crater diameter for each energy density. By fitting a curve that related the ablation threshold with the energy density and the corresponding diameter of ablation crater, it was possible to determine the ablation threshold. The results showed that the ablation threshold of the Er,Cr:YSGG in bone tissue was 1.95+/-0.42 J/cm2.

  11. Computer-aided osteotomy design for harvesting autologous bone grafts in reconstructive surgery

    NASA Astrophysics Data System (ADS)

    Krol, Zdzislaw; Zerfass, Peter; von Rymon-Lipinski, Bartosz; Jansen, Thomas; Hauck, Wolfgang; Zeilhofer, Hans-Florian U.; Sader, Robert; Keeve, Erwin

    2001-05-01

    Autologous grafts serve as the standard grafting material in the treatment of maxillofacial bone tumors, traumatic defects or congenital malformations. The pre-selection of a donor site depends primarily on the morphological fit of the available bone mass and the shape of the part that has to be transplanted. To achieve sufficient incorporation of the autograft into the host bone, precise planning and simulation of the surgical intervention based on 3D CT studies is required. This paper presents a method to identify an optimal donor site by performing an optimization of appropriate similarity measures between donor region and a given transplant. At the initial stage the surgeon has to delineate the osteotomy border lines in the template CT data set and to define a set of constraints for the optimization of appropriate similarity measures between donor region and a given transplant. At the initial stage the surgeon has to delineate the osteotomy border lines in the template CT data set and to define a set of constraints for the optimization task in the donor site CT data set. The following fully automatic optimization stage delivers a set of sub-optimal and optimal donor sites for a given template. All generated solutions can be explored interactively on the computer display using an efficient graphical interface. Reconstructive operations supported by our system were performed on 28 patients. We found that the operation time can be considerably shortened by this approach.

  12. Influence of prosthesis design and implantation technique on implant stresses after cementless revision THR

    PubMed Central

    2011-01-01

    Background Femoral offset influences the forces at the hip and the implant stresses after revision THR. For extended bone defects, these forces may cause considerable bending moments within the implant, possibly leading to implant failure. This study investigates the influences of femoral anteversion and offset on stresses in the Wagner SL revision stem implant under varying extents of bone defect conditions. Methods Wagner SL revision stems with standard (34 mm) and increased offset (44 mm) were virtually implanted in a model femur with bone defects of variable extent (Paprosky I to IIIb). Variations in surgical technique were simulated by implanting the stems each at 4° or 14° of anteversion. Muscle and joint contact forces were applied to the reconstruction and implant stresses were determined using finite element analyses. Results Whilst increasing the implant's offset by 10 mm led to increased implant stresses (16.7% in peak tensile stresses), altering anteversion played a lesser role (5%). Generally, larger stresses were observed with reduced bone support: implant stresses increased by as much as 59% for a type IIIb defect. With increased offset, the maximum tensile stress was 225 MPa. Conclusion Although increased stresses were observed within the stem with larger offset and increased anteversion, these findings indicate that restoration of offset, key to restoring joint function, is unlikely to result in excessive implant stresses under routine activities if appropriate fixation can be achieved. PMID:21569522

  13. Recent improvements in SPE3D: a VR-based surgery planning environment

    NASA Astrophysics Data System (ADS)

    Witkowski, Marcin; Sitnik, Robert; Verdonschot, Nico

    2014-02-01

    SPE3D is a surgery planning environment developed within TLEMsafe project [1] (funded by the European Commission FP7). It enables the operator to plan a surgical procedure on the customized musculoskeletal (MS) model of the patient's lower limbs, send the modified model to the biomechanical analysis module, and export the scenario's parameters to the surgical navigation system. The personalized patient-specific three-dimensional (3-D) MS model is registered with 3-D MRI dataset of lower limbs and the two modalities may be visualized simultaneously. Apart from main planes, any arbitrary MRI cross-section can be rendered on the 3-D MS model in real time. The interface provides tools for: bone cutting, manipulating and removal, repositioning muscle insertion points, modifying muscle force, removing muscles and placing implants stored in the implant library. SPE3D supports stereoscopic viewing as well as natural inspection/manipulation with use of haptic devices. Alternatively, it may be controlled with use of a standard computer keyboard, mouse and 2D display or a touch screen (e.g. in an operating room). The interface may be utilized in two main fields. Experienced surgeons may use it to simulate their operative plans and prepare input data for a surgical navigation system while student or novice surgeons can use it for training.

  14. Comparison of Actual Surgical Outcomes and 3D Surgical Simulations

    PubMed Central

    Tucker, Scott; Cevidanes, Lucia; Styner, Martin; Kim, Hyungmin; Reyes, Mauricio; Proffit, William; Turvey, Timothy

    2009-01-01

    Purpose The advent of imaging software programs have proved to be useful for diagnosis, treatment planning, and outcome measurement, but precision of 3D surgical simulation still needs to be tested. This study was conducted to determine if the virtual surgery performed on 3D models constructed from Cone-beam CT (CBCT) can correctly simulate the actual surgical outcome and to validate the ability of this emerging technology to recreate the orthognathic surgery hard tissue movements in 3 translational and 3 rotational planes of space. Methods Construction of pre- and post-surgery 3D models from CBCTs of 14 patients who had combined maxillary advancement and mandibular setback surgery and 6 patients who had one-piece maxillary advancement surgery was performed. The post-surgery and virtually simulated surgery 3D models were registered at the cranial base to quantify differences between simulated and actual surgery models. Hotelling T-test were used to assess the differences between simulated and actual surgical outcomes. Results For all anatomic regions of interest, there was no statistically significant difference between the simulated and the actual surgical models. The right lateral ramus was the only region that showed a statistically significant, but small difference when comparing two- and one-jaw surgeries. Conclusions Virtual surgical methods were reliably reproduced, oral surgery residents could benefit from virtual surgical training, and computer simulation has the potential to increase predictability in the operating room. PMID:20591553

  15. Primary Eosinophilic Granuloma of Adult Cervical Spine Presenting as a Radiculomyelopathy

    PubMed Central

    Bang, Woo-Seok; Cho, Dae-Chul; Sung, Joo-Kyung

    2013-01-01

    We report a case of 29-year-old man diagnosed as a primary eosinophilic granuloma (EG) lesion of the seventh cervical vertebra. He had paresthesia on both arms, and grasping weakness for 10 days. Cervical magnetic resonance image (MRI) showed an enhancing mass with ventral epidural bulging and cord compression on the seventh cervical vertebra. Additionally, we performed spine series MRI, bone scan and positive emission tomography for confirmation of other bone lesions. These studies showed no other pathological lesions. He underwent anterior cervical corpectomy of the seventh cervical vertebra and plate fixation with iliac bone graft. After surgical management, neurological symptoms were much improved. Histopathologic evaluation confirmed the diagnosis of EG. There was no evidence of tumor recurrence at 12 months postoperative cervical MRI follow-up. We reported symptomatic primary EG of cervical spine successfully treated with surgical resection. PMID:24044083

  16. Dorsal slab fracture of the fourth carpal bone in a racing greyhound.

    PubMed

    Rutherford, Scott; Ness, Malcolm G

    2012-11-01

    To report the diagnosis and surgical management of a dorsal slab fracture of the fourth carpal bone in a racing greyhound. Clinical report. Three-year-old, male racing Greyhound. The fracture was not visible on orthogonal radiographs and the diagnosis was made by computed tomography. Open reduction and internal fixation with 2 countersunk 2.0-mm screws inserted in lag fashion was performed via a dorsal approach. Outcome was analyzed objectively by comparing preinjury and postsurgery racing performances. Internal fixation resulted in fracture healing and the dog returned to racing recording times similar to those before injury. Fractures of the fourth carpal bone may not be visible on standard orthogonal radiographic views and cross-sectional imaging may be required for more accurate identification. Surgical management was successful with the dog returning to preinjury levels of competition. © Copyright 2012 by The American College of Veterinary Surgeons.

  17. An evidence-based concept of implant dentistry. Utilization of short and narrow platform implants.

    PubMed

    Ruiz, Jose-Luis

    2012-09-01

    As a profession, we must remember that tooth replacement is not a luxury; it is often a necessity for health reasons. Although bone augmentation and CBCT and expensive surgical guides are often indicated for complex cases, they are being overused. Simple or straightforward implant cases, when there is sufficient natural bone for narrow or shorter implant, can be predictable performed by well-trained GPs and other trained specialists. Complex cases requiring bone augmentation and other complexities as described herein, should be referred to a surgical specialist. Implant courses and curricula have to be based on the level of complexity of implant surgery that each clinician wishes to provide to his or her patients. Using a "logical approach" to implant dentistry keeps cases simple or straightforward, and more accessible to patients by the correct use of narrow and shorter implants.

  18. Clinical evaluation of the efficacy of a GTR membrane (HEALIGUIDE) and demineralised bone matrix (OSSEOGRAFT) as a space maintainer in the treatment of Miller's Class I gingival recession.

    PubMed

    Nanditha, S; Priya, M S; Sabitha, S; Arun, K V; Avaneendra, T

    2011-04-01

    Periodontal plastic surgical procedures aimed at coverage of exposed root surface have evolved into routine treatment modalities. The present study was designed to evaluate the effectiveness and predictability of using a collagen barrier along with a demineralized bone matrix in the treatment of recession defects in a single surgical procedure. Seventeen patients with Miller's class I recession were treated with a combination of a collagen barrier used along with a bone graft and coronally advanced flap technique. Clinical parameters were recorded at baseline, 3 months, 6 months, and 9 months. The study showed a highly significant reduction in the recession depth (70.29 ± 21.96%) at the end of the study. This study showed that the use of this technique for recession coverage is highly predictable and highly esthetic root coverage can be obtained.

  19. Management strategy for unicameral bone cyst.

    PubMed

    Chuo, Chin-Yi; Fu, Yin-Chih; Chien, Song-Hsiung; Lin, Gau-Tyan; Wang, Gwo-Jaw

    2003-06-01

    The management of a unicameral bone cyst varies from percutaneous needle biopsy, aspiration, and local injection of steroid, autogenous bone marrow, or demineralized bone matrix to the more invasive surgical procedures of conventional curettage and grafting (with autogenous or allogenous bone) or subtotal resection with bone grafting. The best treatment for a unicameral bone cyst is yet to be identified. Better understanding of the pathology will change the concept of management. The aim of treatment is to prevent pathologic fracture, to promote cyst healing, and to avoid cyst recurrence and re-fracture. We retrospectively reviewed 17 cases of unicameral bone cysts (12 in the humerus, 3 in the femur, 2 in the fibula) managed by conservative observation, curettage and bone grafting with open reduction and internal fixation, or continuous decompression and drainage with a cannulated screw. We suggest percutaneous cannulated screw insertion to promote cyst healing and prevent pathologic fracture. We devised a protocol for the management of unicameral bone cysts.

  20. Current surgical strategies for total arthroplasty in valgus knee

    PubMed Central

    Nikolopoulos, Dimitrios; Michos, Ioannis; Safos, George; Safos, Petros

    2015-01-01

    The majority of orthopaedic surgeons even currently agree that primary total arthroplasty in valgus knees with a deformity of more than ten degrees may prove challenging. The unique sets of bone and soft tissue abnormalities that must be addressed at the time of the operation make accurate axis restoration, component orientation and joint stability attainment a difficult task. Understanding the specific pathologic anatomic changes associated with the valgus knee is a prerequisite so as to select the proper surgical method, to optimize component position and restore soft-tissue balance. The purpose of this article is to review the valgus knee anatomical variations, to assess the best pre-operative planning and to evaluate how to choose the grade of constraint of the implant. It will also be underlying the up-to-date main approaches and surgical techniques be proposed in the English literature both for bone cuts and soft tissue management of valgus knees. PMID:26191494

  1. Enucleation and liquid nitrogen cryotherapy in the treatment of keratocystic odontogenic tumors: a case series.

    PubMed

    Tonietto, Leonardo; Borges, Hedelson Odenir Iecher; Martins, Carlos Alberto Medeiros; Silva, Daniela Nascimento; Sant'Ana Filho, Manoel

    2011-06-01

    This study describes the technique of lesion enucleation without capsule disruption combined with liquid nitrogen cryotherapy in the surgical treatment of keratocystic odontogenic tumors (KOTs). Eight patients (9 KOTs) were included in the study. After enucleation, liquid nitrogen was applied twice for 1 minute, with 5-minute intervals between applications. The patients were followed up for 3 to 9 years. There were no recurrences during the follow-up of 9 KOTs for up to 9 years. Only 1 patient had temporary reversible loss of lip sensation after treatment. There were no pathologic fractures. In all cases bone height at the surgical site was restored, and no patients needed bone reconstruction for post-treatment rehabilitation. This study confirmed the efficiency of KOT treatment enucleation without fragmentation combined with liquid nitrogen cryotherapy at the surgical site. Copyright © 2011 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Delayed surgical treatment for neglected or mal-reduced talar fractures.

    PubMed

    Huang, Peng-Ju; Cheng, Yuh-Min

    2005-10-01

    From 1993 to 2002, we treated nine patients for neglected or mal-reduced talar fractures. Average patient age was 39 (20-64) years and average follow-up 53 months. The time interval between injury and index operation ranged from 4 weeks to 4 years. Surgical procedures included open reduction with or without bone grafting in six cases, open reduction combined with ankle fusion in one case, talar neck osteotomy in one case, and talar neck osteotomy combined with subtalar fusion in one case. All cases had solid bone union. One patient developed avascular necrosis of the talus needing subsequent ankle arthrodesis. In six patients, adjacent hindfoot arthrosis occurred. The overall AOFAS ankle-hindfoot score was in average 77.4. We conclude that in neglected and mal-reduced talar fractures, surgical treatment can lead to a favourable outcome if the hindfoot joints are not arthritic.

  3. Robotics in Orthopedics: A Brave New World.

    PubMed

    Parsley, Brian S

    2018-02-16

    Future health-care projection projects a significant growth in population by 2020. Health care has seen an exponential growth in technology to address the growing population with the decreasing number of physicians and health-care workers. Robotics in health care has been introduced to address this growing need. Early adoption of robotics was limited because of the limited application of the technology, the cumbersome nature of the equipment, and technical complications. A continued improvement in efficacy, adaptability, and cost reduction has stimulated increased interest in robotic-assisted surgery. The evolution in orthopedic surgery has allowed for advanced surgical planning, precision robotic machining of bone, improved implant-bone contact, optimization of implant placement, and optimization of the mechanical alignment. The potential benefits of robotic surgery include improved surgical work flow, improvements in efficacy and reduction in surgical time. Robotic-assisted surgery will continue to evolve in the orthopedic field. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Giant Cell Tumor of Bone - An Overview

    PubMed Central

    Sobti, Anshul; Agrawal, Pranshu; Agarwala, Sanjay; Agarwal, Manish

    2016-01-01

    Giant Cell tumors (GCT) are benign tumors with potential for aggressive behavior and capacity to metastasize. Although rarely lethal, benign bone tumors may be associated with a substantial disturbance of the local bony architecture that can be particularly troublesome in peri-articular locations. Its histogenesis remains unclear. It is characterized by a proliferation of mononuclear stromal cells and the presence of many multi- nucleated giant cells with homogenous distribution. There is no widely held consensus regarding the ideal treatment method selection. There are advocates of varying surgical techniques ranging from intra-lesional curettage to wide resection. As most giant cell tumors are benign and are located near a joint in young adults, several authors favor an intralesional approach that preserves anatomy of bone in lieu of resection. Although GCT is classified as a benign lesion, few patients develop progressive lung metastases with poor outcomes. Treatment is mainly surgical. Options of chemotherapy and radiotherapy are reserved for selected cases. Recent advances in the understanding of pathogenesis are essential to develop new treatments for this locally destructive primary bone tumor. PMID:26894211

  5. Advances in biologic augmentation for rotator cuff repair

    PubMed Central

    Patel, Sahishnu; Gualtieri, Anthony P.; Lu, Helen H.; Levine, William N.

    2016-01-01

    Rotator cuff tear is a very common shoulder injury that often necessitates surgical intervention for repair. Despite advances in surgical techniques for rotator cuff repair, there is a high incidence of failure after surgery because of poor healing capacity attributed to many factors. The complexity of tendon-to-bone integration inherently presents a challenge for repair because of a large biomechanical mismatch between the tendon and bone and insufficient regeneration of native tissue, leading to the formation of fibrovascular scar tissue. Therefore, various biological augmentation approaches have been investigated to improve rotator cuff repair healing. This review highlights recent advances in three fundamental approaches for biological augmentation for functional and integrative tendon–bone repair. First, the exploration, application, and delivery of growth factors to improve regeneration of native tissue is discussed. Second, applications of stem cell and other cell-based therapies to replenish damaged tissue for better healing is covered. Finally, this review will highlight the development and applications of compatible biomaterials to both better recapitulate the tendon–bone interface and improve delivery of biological factors for enhanced integrative repair. PMID:27750374

  6. Diaphyseal forearm fractures, 20 years after surgical treatment. Is there still an indication for percutaneous fixation?

    PubMed

    Fernández-Marín, M R; Hidalgo-Pérez, M; Arias-Rodríguez, G; García-Mendoza, A; Prada-Chamorro, E; Domecq-Fernández de Bobadilla, G

    This is a retrospective study of 98 diaphyseal forearm fractures in adults, treated by a percutaneous technique with intramedullar Kirchner wires. We reviewed 64 patients with 98 forearm fractures with a radiographic follow-up, assessing the presence of pseudarthrosis or delayed bone union and evaluating functional outcomes with the Anderson and the Disability of the Arm, Shoulder and Hand scale. Clinical and radiological bone union was achieved in an average of 12 weeks. We obtained 77% of excellent and good results following Anderson's scale. There were 4 cases of pseudarthrosis and 6 cases of delayed bone union. This surgical technique provides several advantages, such as a low incidence of complications and a total absence of infections, refractures and iatrogenic neurovascular injuries. It allows a lower hospital stay and a shortening of the surgery time compared with other techniques such as plates and intramedullary nails, that have similar results, in terms of bone union and functional outcomes, as we have verified from the published literature. Copyright © 2017 SECOT. Publicado por Elsevier España, S.L.U. All rights reserved.

  7. Three-dimensional simulation of ultrasound propagation through trabecular bone structures measured by synchrotron microtomography.

    PubMed

    Bossy, Emmanuel; Padilla, Frédéric; Peyrin, Françoise; Laugier, Pascal

    2005-12-07

    Three-dimensional numerical simulations of ultrasound transmission were performed through 31 trabecular bone samples measured by synchrotron microtomography. The synchrotron microtomography provided high resolution 3D mappings of bone structures, which were used as the input geometry in the simulation software developed in our laboratory. While absorption (i.e. the absorption of ultrasound through dissipative mechanisms) was not taken into account in the algorithm, the simulations reproduced major phenomena observed in real through-transmission experiments in trabecular bone. The simulated attenuation (i.e. the decrease of the transmitted ultrasonic energy) varies linearly with frequency in the MHz frequency range. Both the speed of sound (SOS) and the slope of the normalized frequency-dependent attenuation (nBUA) increase with the bone volume fraction. Twenty-five out of the thirty-one samples exhibited negative velocity dispersion. One sample was rotated to align the main orientation of the trabecular structure with the direction of ultrasonic propagation, leading to the observation of a fast and a slow wave. Coupling numerical simulation with real bone architecture therefore provides a powerful tool to investigate the physics of ultrasound propagation in trabecular structures. As an illustration, comparison between results obtained on bone modelled either as a fluid or a solid structure suggested the major role of mode conversion of the incident acoustic wave to shear waves in bone to explain the large contribution of scattering to the overall attenuation.

  8. Clinical and histologic outcomes of calcium sulfate in the treatment of postextraction sockets.

    PubMed

    Ruga, Emanuele; Gallesio, Cesare; Chiusa, Luigi; Boffano, Paolo

    2011-03-01

    The aim of this prospective study was to assess the clinical and histologic outcomes obtained with calcium sulfate (CS) used as a filler material in fresh premolar and molar postextraction sockets. Sixty premolar or molar postextraction sockets were filled with CS. Among the 60 grafted sockets, after 3 months, 50 underwent implant placement and clinical assessment. The removal of a sample core of newly generated intrasocket tissue was performed in 19 sockets. Collected samples were sent for histologic examination. The percentage of vital bone, nonvital bone, residual CS, amorphous material, and connective areas in every sample was calculated and recorded. Fifty postextraction regenerated sockets that underwent implant placement 3 months after tooth removal were included in this study.A partial postoperative exposition of the graft was observed in 12 of 50 sockets. At the surgical reentry, the augmented extraction sockets were completely filled by a hard material with an adequate alveolar crest in 41 cases. Histologic examination of the cores revealed that 63.16% of the intrasocket tissue was new vital bone, 2.1% was nonvital bone, 4.74% was fibrous tissue, and 30% was amorphous material. No residual CS was identified in bone cores. This study confirmed that CS is an ideal grafting material. The clinical adequacy aspect of filled sockets at surgical reentry seemed to be indicative of a qualitatively better bone regeneration. Postoperative exposition of graft material after a first intervention seemed to constitute an important risk factor for a worse bone regeneration.

  9. The effects of photobiomodulation on healing of bone defects in streptozotocin induced diabetic rats

    NASA Astrophysics Data System (ADS)

    Martinez Costa Lino, Maíra D.; Bastos de Carvalho, Fabíola; Ferreira Moraes, Michel; Augusto Cardoso, José; Pinheiro, Antônio L. B.; Maria Pedreira Ramalho, Luciana

    2011-03-01

    Previous studies have shown positive effects of Low level laser therapy (LLLT) on the repair of bone defects, but there are only a few that associates bone healing in the presence of a metabolic disorder as Diabetes Melitus and LLLT. The aim of this study was to assess histologically the effect of LLLT (AsGaAl), 780nm, 70mW, CW, Ø~0.4mm, 16J/cm2 per session) on the repair of surgical defects created in the femur of diabetic and non-diabetic Wistar Albinus rats. Surgical bone defects were created in 60 animals divided into four groups of 15 animals each: Group C (non-diabetic - control); Group CL (non-diabetic + LLLT); Group CD (diabetic); Group CDL (diabetic + LLLT). The animals on the irradiated group received 16 J/cm2 per session divided into four points around the defect, being the first irradiation immediately after surgery and repeated every 48h for 14 days. The animals were killed 15, 21 and 30 days after surgery. The results of the present investigation showed histological evidence of improved amount of collagen fibers at early stages of the bone healing (15 days) and increased amount of well organized bone trabeculae at the end of the experimental period (30 days) on irradiated animals, (diabetic and non-diabetic) compared to non irradiated ones. It is concluded that LLLT has a positive biomodulative effect on the healing process of bone defects, even when diabetes mellitus was present.

  10. Heterotopic ossification revisited.

    PubMed

    Mavrogenis, Andreas F; Soucacos, Panayotis N; Papagelopoulos, Panayiotis J

    2011-03-11

    Heterotopic ossification is the abnormal formation of mature lamellar bone within extraskeletal soft tissues where bone does not exist. Heterotopic ossification has been classified into posttraumatic, nontraumatic or neurogenic, and myositis ossificans progressiva or fibrodysplasia ossificans progressive. The pathophysiology is unknown. Anatomically, heterotopic ossification occurs outside the joint capsule without disrupting it. The new bone can be contiguous with the skeleton but generally does not involve the periosteum. Three-phase technetium-99m (99mTc) methylene diphosphonate bone scan is the most sensitive imaging modality for early detection and assessing the maturity of heterotopic ossification. Nonsurgical treatment with indomethacin and radiation therapy is appropriate for prophylaxis or early treatment of heterotopic ossification. Although bisphosphonates are effective prophylaxis if initiated shortly after the trauma, mineralization of the bone matrix resumes after drug discontinuation. During the acute inflammatory stage, the patient should rest the involved joint in a functional position; once acute inflammatory signs subside, passive range of motion exercises and continued mobilization are indicated. Surgical indications for excision of heterotopic ossification include improvement of function, standing posture, sitting or ambulation, independent dressing, feeding and hygiene, and repeated pressure sores from underlying bone mass. The optimal timing of surgery has been suggested to be a delay of 12 to 18 months until radiographic evidence of heterotopic ossification maturation and maximal recovery after neurological injury. The ideal candidate for surgical treatment before 18 months should have no joint pain or swelling, a normal alkaline phosphatase level, and 3-phase bone scan indicating mature heterotopic ossification. Copyright 2011, SLACK Incorporated.

  11. Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study

    PubMed Central

    Flieger, Rafał; Dominiak, Marzena

    2016-01-01

    The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles (n = 60) of adult pigs, divided into 4 groups (n = 15). Two vertical and one horizontal cut have been done in an alveolar ridge using Er:YAG laser with set power of 200 mJ (G1), 400 mJ (G2), piezosurgery unit (G3), and a saw (G4). The temperature was measured by K-type thermocouple. The highest temperature gradient was noted for piezosurgery on the buccal and lingual side of mandible. The temperature rises on the bone surface along with the increase of laser power. The lower time needed to perform ridge splitting was measured for a saw, piezosurgery, and Er:YAG laser with power of 400 mJ and 200 mJ, respectively. The temperature rise measured on the bone over 10°C and bone carbonization occurrence was not reported in all study groups. Piezosurgery, Er:YAG laser (200 mJ and 400 mJ), and surgical saw are useful and safe tools in ridge splitting surgery. PMID:27957502

  12. Assessment of Temperature Rise and Time of Alveolar Ridge Splitting by Means of Er:YAG Laser, Piezosurgery, and Surgical Saw: An Ex Vivo Study.

    PubMed

    Matys, Jacek; Flieger, Rafał; Dominiak, Marzena

    2016-01-01

    The most common adverse effect after bone cutting is a thermal damage. The aim of our study was to evaluate the bone temperature rise during an alveolar ridge splitting, rating the time needed to perform this procedure and the time to raise the temperature of a bone by 10°C, as well as to evaluate the bone carbonization occurrence. The research included 60 mandibles ( n = 60) of adult pigs, divided into 4 groups ( n = 15). Two vertical and one horizontal cut have been done in an alveolar ridge using Er:YAG laser with set power of 200 mJ (G1), 400 mJ (G2), piezosurgery unit (G3), and a saw (G4). The temperature was measured by K-type thermocouple. The highest temperature gradient was noted for piezosurgery on the buccal and lingual side of mandible. The temperature rises on the bone surface along with the increase of laser power. The lower time needed to perform ridge splitting was measured for a saw, piezosurgery, and Er:YAG laser with power of 400 mJ and 200 mJ, respectively. The temperature rise measured on the bone over 10°C and bone carbonization occurrence was not reported in all study groups. Piezosurgery, Er:YAG laser (200 mJ and 400 mJ), and surgical saw are useful and safe tools in ridge splitting surgery.

  13. Lactobacillus reuteri 6475 Increases Bone Density in Intact Females Only under an Inflammatory Setting

    PubMed Central

    Collins, Fraser L.; Irwin, Regina; Bierhalter, Hayley; Schepper, Jonathan; Britton, Robert A.

    2016-01-01

    Background & Aims We previously demonstrated that short-term oral administration of the probiotic Lactobacillus reuteri 6475 enhanced bone density in male but not female mice. We also established that L. reuteri 6475 enhanced bone health and prevented bone loss in estrogen-deficient female mice. In this study, we tested whether a mild inflammatory state and/or a long-term treatment with the probiotic was required to promote a positive bone effect in estrogen-sufficient female mice. Methods A mild inflammatory state was induced in female mice by dorsal surgical incision (DSI). Following DSI animals were orally supplemented with L. reuteri or vehicle control for a period of 8 weeks. Gene expression was measured in the intestine and bone marrow by qPCR. Distal femoral bone density and architecture was analyzed by micro-CT. Results We report that 8 weeks after DSI there is a significant increase in the weight of spleen, thymus and visceral (retroperitoneal) fat pads. Expression of intestinal cytokines and tight junction proteins are also altered 8 weeks post-DSI. Interestingly, L. reuteri treatment was found to display both intestinal region- and inflammation-dependent effects. Unexpectedly we identified that 1) L. reuteri treatment increased bone density in females but only in those that underwent DSI and 2) DSI benefited cortical bone parameters. In the bone marrow, dorsal surgery induced CD4+ T cell numbers, a response that was unaffected by L. reuteri treatment, whereas expression of RANKL, OPG and IL-10 were significantly affected by L. reuteri treatment. Conclusion Our data reveals a previously unappreciated effect of a mild surgical procedure causing a long-lasting effect on inflammatory gene expression in the gut and the bone. Additionally, we demonstrate that in intact female mice, the beneficial effect of L. reuteri on bone requires an elevated inflammatory status. PMID:27058036

  14. Stem geometry changes initial femoral fixation stability of a revised press-fit hip prosthesis: A finite element study.

    PubMed

    Russell, Robert D; Huo, Michael H; Rodrigues, Danieli C; Kosmopoulos, Victor

    2016-11-14

    Stable femoral fixation during uncemented total hip arthroplasty is critical to allow for subsequent osseointegration of the prosthesis. Varying stem designs provide surgeons with multiple options to gain femoral fixation. The purpose of this study was to compare the initial fixation stability of cylindrical and tapered stem implants using two different underreaming techniques (press-fit conditions) for revision total hip arthroplasty (THA). A finite element femur model was created from three-dimensional computed tomography images simulating a trabecular bone defect commonly observed in revision THA. Two 18-mm generic femoral hip implants were modeled using the same geometry, differing only in that one had a cylindrical stem and the other had a 2 degree tapered stem. Surgery was simulated using a 0.05-mm and 0.01-mm press-fit and tested with a physiologically relevant loading protocol. Mean contact pressure was influenced more by the surgical technique than by the stem geometry. The 0.05-mm press-fit condition resulted in the highest contact pressures for both the cylindrical (27.35 MPa) and tapered (20.99 MPa) stems. Changing the press-fit to 0.01-mm greatly decreased the contact pressure by 79.8% and 78.5% for the cylindrical (5.53 MPa) and tapered (4.52 MPa) models, respectively. The cylindrical stem geometry consistently showed less relative micromotion at all the cross-sections sampled as compared to the tapered stem regardless of press-fit condition. This finite element analysis study demonstrates that tapered stem results in lower average contact pressure and greater micromotion at the implant-bone interface than a cylindrical stem geometry. More studies are needed to establish how these different stem geometries perform in such non-ideal conditions encountered in revision THA cases where less bone stock is available.

  15. A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fractures.

    PubMed

    Basso, Trude; Klaksvik, Jomar; Syversen, Unni; Foss, Olav A

    2014-12-18

    Fourth generation composite femurs (4GCFs, models #3406 and #3403) simulate femurs of males <80 years with good bone quality. Since most hip fractures occur in old women with fragile bones, concern is raised regarding the use of standard 4GCFs in biomechanical experiments. In this study the stability of hip fracture fixations in 4GCFs was compared to human cadaver femurs (HCFs) selected to represent patients with hip fractures. Ten 4GCFs (Sawbones, Pacific Research Laboratories, Inc., Vashon, WA, USA) were compared to 24 HCFs from seven females and five males >60 years. Proximal femur anthropometric measurements were noted. Strain gauge rosettes were attached and femurs were mounted in a hip simulator applying a combined subject-specific axial load and torque. Baseline measurements of resistance to deformation were recorded. Standardized femoral neck fractures were surgically stabilized before the constructs were subjected to 20,000 load-cycles. An optical motion tracking system measured relative movements. Median (95% CI) head fragment migration was 0.8mm (0.4 to 1.1) in the 4GCF group versus 2.2mm (1.5 to 4.6) in the cadaver group (p=0.001). This difference in fracture stability could not be explained by observed differences in femoral anthropometry or potential overloading of 4GCFs. 4GCFs failed with fracture-patterns different from those observed in cadavers. To conclude, standard 4GCFs provide unrealistically stable bone-implant constructs and fail with fractures not observed in cadavers. Until a validated osteopenic or osteoporotic composite femur model is provided, standard 4GCFs should only be used when representing the biomechanical properties of young healthy femurs. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. The effect of phototherapies on bone repair of euthyroid and hypothyroid rats: Raman spectroscopic study

    NASA Astrophysics Data System (ADS)

    Soares, Amanda P.; Rodriguez, Tania T.; Soares, Luiz G. P.; dos Santos, Jean Nunes; Silveira, Landulfo; Pinheiro, Antonio Luiz B.

    2018-04-01

    The repair of bone tissue is complex and can be influenced by several local and systemic factors that can delay the repair. Laser and LED phototherapies have shown positive results in the repair of bone tissue. The aim of this study was to evaluate, through Raman spectroscopy, the influence of laser (λ780 nm) and LED (λ850 nm) phototherapies in the repair of surgical defects in femurs of euthyroid and hypothyroid rats. Thirty Albinus Wistar rats were randomly divided into 6 groups. The animals of the hypothyroid groups were submitted to surgical removal of the thyroid gland. After general anesthesia, a surgical bone defect was created in the femur of each animal and filled with blood clot in all groups. In group I (Euthyroid) the defect was created in euthyroid animals; In Group II (Hypo) the defect was created in hypothyroid animals; In Group III (Euthyroid Laser) the defect was irradiated with Laser; on Group IV (Hypo Laser) the defect was made in a hypothyroid animal and irradiated with Laser; on Group V (Euthyroid LED) the defect was irradiated with LED and on Group VI (Hypo LED) the defect was created in hypothyroid animals and LED irradiated. Irradiation was carried out at every 48-h for 15 days. Specimens were taken and stored in liquid nitrogen. Intensity of peaks of phosphate HA ( 960 cm-1), carbonated HA ( 1,070 cm-1) and collagen ( 1,414 cm-1) were measured by Raman Spectroscopy. The results showed that the health status had significant influence all peaks. Irradiation influenced only the peak of 1454 cm-1. It is concluded that phototherapies influences bone repair in cases of thyroid diseases.

  17. Difficult situations managing diabetic foot. Evidences and personal views: is to operate on patients with diabetic foot osteomyelitis old-fashioned?

    PubMed

    Senneville, Eric; Nguyen, Sophie

    2014-12-01

    Both medical and surgical approaches have been shown to be effective in the treatment of patients with diabetic foot osteomyelitis (DFO). In patients with risk factors of bad outcome such as major bone destruction, concomitant acute infections requiring drainage, problems in limb perfusion, highly resistant bacteria, and contraindication for or patient refusal of prolonged antibiotic therapy, the choice of surgery does not require further discussion. On the contrary, modest changes of bone on imaging assessment and no limiting factors as described above make medical treatment an attractive option for patients with DFO provided the rules of antibiotic treatment of chronic osteomyelitis are respected. The key question may not be to oppose surgery and medical treatment but to identify patients who need surgery and those who do not. There is currently no classification or score system that may allow physician to decide whether medical or surgical approach is best adapted to a given patient, and so both experience and skill of the multidisciplinary team appear paramount for guiding the choice of the best adapted ("tailored") strategy in a given patient. In this regard, it would be interesting to compare surgical and medical approaches for DFO that apparently may benefit from one or another (ie, bone lesions seen on plain radiographs of the foot but without bone fragmentation or multiple sites of osteomyelitis, no contraindication to prolonged antibiotic therapy, and location of bone involvement that may allow conservative surgery). Given the current available data on the therapeutic options of DFO, it appears that surgery for those patients is obviously not an old-fashioned option. © The Author(s) 2014.

  18. [Patellar bone deficiency in revision total knee arthroplasty].

    PubMed

    Kloiber, J; Goldenitsch, E; Ritschl, P

    2016-05-01

    Patellar bone deficiency in revision total knee arthroplasty (TKA) determines the surgical procedure. Different reconstructive and ablative techniques, dependent on the remaining bone stock, are described. The primary patella implant can be retained in up to 50 % of revision situations. Reasons for replacement are aseptic and septic loosening, implant failure, expanding osteolysis, maltracking of the patella and "metal-backed" prosthesis. The aim of the reconstruction is the stable fixation and proper tracking of the implant by restoring the extensor mechanism. Dependent on the extent of bone loss and the availability of a patellar rim, the following surgical procedures are recommended. When the remaining bone thickness is 10 mm or more: implantation of a polyethylene "onlay-type" patella; when it is between 6-9 mm and there is an intact patellar rim: reconstruction with a biconvex "inlay-type" patella implant, where the biconvex shape replaces the bone defect partially. When there is deficient bone stock (less than 6 mm) or no cortical patellar rim then augmenting procedures with autologous spongiosa and procedures such as "impaction bone grafting", "trabecular metal" prosthesis, where the trabecular part of the implant serves as the base for the cemented polyethylene button, "gull-wing" osteotomy, which is an adapting and configuring technique of osteotomy; and in exceptional cases patelloplasty or patellectomy are used. Regarding the importance of the patellar component in biomechanics of the joint and function of the extensor mechanism, the reconstruction of the patella should be the primary aim. Patelloplasty or patellectomy should be avoided.

  19. Surgical complications associated with primary closure in patients with diabetic foot osteomyelitis

    PubMed Central

    García-Morales, Esther; Lázaro-Martínez, José Luis; Aragón-Sánchez, Javier; Cecilia-Matilla, Almudena; García-Álvarez, Yolanda; Beneit-Montesinos, Juan Vicente

    2012-01-01

    Background The aim of this study was to determine the incidence of complications associated with primary closure in surgical procedures performed for diabetic foot osteomyelitis compared to those healed by secondary intention. In addition, further evaluation of the surgical digital debridement for osteomyelitis with primary closure as an alternative to patients with digital amputation was also examined in our study. Methods Comparative study that included 46 patients with diabetic foot ulcerations. Surgical debridement of the infected bone was performed on all patients. Depending on the surgical technique used, primary surgical closure was performed on 34 patients (73.9%, Group 1) while the rest of the 12 patients were allowed to heal by secondary intention (26.1%, Group 2). During surgical intervention, bone samples were collected for both microbiological and histopathological analyses. Post-surgical complications were recorded in both groups during the recovery period. Results The average healing time was 9.9±SD 8.4 weeks in Group 1 and 19.1±SD 16.9 weeks in Group 2 (p=0.008). The percentage of complications was 61.8% in Group 1 and 58.3% in Group 2 (p=0.834). In all patients with digital ulcerations that were necessary for an amputation, a primary surgical closure was performed with successful outcomes. Discussion Primary surgical closure was not associated with a greater number of complications. Patients who received primary surgical closure had faster healing rates and experienced a lower percentage of exudation (p=0.05), edema (p<0.001) and reinfection, factors that determine the delay in wound healing and affect the prognosis of the surgical outcome. Further research with a greater number of patients is required to better define the cases for which primary surgical closure may be indicated at different levels of the diabetic foot. PMID:23050062

  20. Simulators and virtual reality in surgical education.

    PubMed

    Chou, Betty; Handa, Victoria L

    2006-06-01

    This article explores the pros and cons of virtual reality simulators, their abilities to train and assess surgical skills, and their potential future applications. Computer-based virtual reality simulators and more conventional box trainers are compared and contrasted. The virtual reality simulator provides objective assessment of surgical skills and immediate feedback further to enhance training. With this ability to provide standardized, unbiased assessment of surgical skills, the virtual reality trainer has the potential to be a tool for selecting, instructing, certifying, and recertifying gynecologists.

  1. New Age Teaching: Beyond Didactics

    PubMed Central

    Vlaovic, Peter D.; McDougall, Elspeth M.

    2006-01-01

    Widespread acceptance of laparoscopic urology techniques has posed many challenges to training urology residents and allowing postgraduate urologists to acquire often difficult new surgical skills. Several factors in surgical training programs are limiting the ability to train residents in the operating room, including limited-hours work weeks, increasing demand for operating room productivity, and general public awareness of medical errors. As such, surgical simulation may provide an opportunity to enhance residency experience and training, and optimize post-graduate acquisition of new skills and maintenance of competency. This review article explains and defines the various levels of validity as it pertains to surgical simulators. The most recently and comprehensively validity tested simulators are outlined and summarized. The potential role of surgical simulation in the formative and summative assessment of surgical trainees, as well as, the certification and recertification process of postgraduate surgeons will be delineated. Surgical simulation will be an important adjunct to the traditional methods of surgical skills training and will allow surgeons to maintain their proficiency in the technically challenging aspects of minimally invasive urologic surgery. PMID:17619704

  2. Metachronous bilateral subtrochanteric fracture of femur in an osteopetrotic bone: A case report with technical note.

    PubMed

    Kumar, Dharmendra; Jain, Vijay Kumar; Lal, Hitesh; Arya, Rajinder Kumar; Sinha, Skand

    2012-12-01

    Osteopetrosis is a rare inherited skeletal disorder characterized by increased density. The increased fragility of such dense bone results in a greater incidence of fractures, especially around hip and proximal femur. The surgical treatment of such fractures is difficult due to hard but brittle structure of bone. Herein we report a case of bilateral subtrochanteric fracture in an osteopetrotic patient. It was fixed using a dynamic hip screw with plate.

  3. Surgical management of calcaneal unicameral bone cysts.

    PubMed

    Glaser, D L; Dormans, J P; Stanton, R P; Davidson, R S

    1999-03-01

    Unicameral bone cysts are not seen commonly in the calcaneus. Little is known about the etiology and natural history of these lesions. Calcaneal cysts often are symptomatic, although some of these lesions are detected as incidental findings. Treatment has been advocated based on the fear of pathologic fracture and collapse. Several published series have been divided in their favor for either open treatment or injection management. These series are small, and the optimal treatment is still in question. The current study compared the efficacy of methylprednisolone acetate injection treatment with curettage and bone grafting in the treatment of unicameral bone cysts of the calcaneus. All patients treated for unicameral bone cysts of the calcaneus during the past 7 years at two institutions were reviewed. Eleven patients met inclusion criteria. All diagnoses were confirmed radiographically or histologically. Demographic information, presenting complaints, diagnostic imaging, treatment modalities, and outcome were analyzed. Long term radiographic and subjective followup was obtained. Eighteen surgical procedures were performed on 11 patients with 12 cysts. Nine injections performed on six patients failed to show healing of the cyst. Nine cysts treated with curettage and bone grafting showed cyst healing. At mean followup of 28 months (range, 12-77 months), all 11 patients had no symptoms; there were no recurrences of the cyst in the nine patients who underwent bone grafting and persistence of the cyst in the two patients who underwent injection therapy. This review reports one of the largest series of cysts in this location. The results indicate that steroid injection treatment, although useful in other locations, may not be the best option for the management of unicameral bone cysts in the calcaneus. Curettage and bone grafting yielded uniformly good results.

  4. Analysis of radiographic bone parameters throughout the surgical lengthening and deformity correction of extremities.

    PubMed

    Atanasov, Nenad; Poposka, Anastasika; Samardziski, Milan; Kamnar, Viktor

    2014-01-01

    Radiographic examination of extremities in surgical lengthening and/or correction of deformities is of crucial importance for the assessment of new bone formation. The purpose of this study is to confirm the diagnostic value of radiography in precise detection of bone parameters in various lengthening or correction stages in patients treated by limb-lengthening and deformity correction. 50 patients were treated by the Ilizarov method of limb lengthening or deformity correction at the University Orthopaedic Surgery Clinic in Skopje, and analysed over the period from 2006 to 2012. The patients were divided into two groups. The first group consisted of 27 patients with limb-lengthening because of congenital shortening. The second group consisted of 23 patients treated for acquired limb deformities. The results in both groups were received in three stages of new bone formation and were based on the appearance of 3 radiographic parameters at the distraction/compression site. The differences between the presence of all radiographic bone parameters in different stages of new bone formation were statistically signficant in both groups, especially the presence of the cortical margin in the first group (Cochran Q=34.43, df=2, p=0.00000). The comparative analysis between the two groups showed a statistically significant difference in the presence of initial bone elements and cystic formations only in the first stage. Almost no statistical significance in the differences between both groups of patients with regard to 3 radiographic parameters in 3 stages of new bone formation, indicates a minor influence of the etiopathogenetic background on the new bone formation in patients treated by gradual lengthening or correction of limb deformities.

  5. Influence of Autologus Adipose Derived Stem Cells and PRP on Regeneration of Dehiscence-Type Defects in Alveolar Bone: A Comparative Histochemical and Histomorphometric Study in Dogs

    PubMed Central

    Aziz Aly, Lobna Abdel; El- Menoufy, Hala; Hassan, Amal; Ragae, Alyaa; Atta, Hazem Mahmoud; Roshdy, Nagwa Kamal; Rashed, Laila Ahmed; Sabry, Dina

    2011-01-01

    Background and Objectives: Autogenous bone grafts is considered to be the best choice for reconstructive surgery. Adipose Derived Stromal Cells (ASCs) represents a promising tool for new clinical concepts in supporting cellular therapy. The goal of our study was to investigate bone regeneration following application of autologous ASCs with or without Platelet-Rich Plasma (PRP) at dehiscence-type defects in alveolar bone in dogs. Methods and Results: Standardized buccal dehiscence defects (4× 3×3 mm) were surgically created in eighteen dogs, the defects were grafted with either ASCs -PRP, ASCs alone, or without grafting material. Three months later; a bone core was harvested from grafted and non grafted sites for histological, histochemical and histomorphometric assessment. There was no evidence of inflammation or adverse tissue reaction with either treatment. Defects grafted with ASCs-PRP showed a significantly higher result (p≤ 0.05), with a mean area % of spongy bone and compact bone of (64.96±5.37 and 837.62±24.95), compared to ASCs alone (47.65±1.43 and 661.92±12.65) and without grafting (33.55± 1.74 and 290.85±7.27) respectively. The area % of lamellated bone increased significantly reaching its highest level in group A followed by group B. Also a significant increase in area % of neutral mucopolysaccharides and calcified reactivity of Masson|s Trichrome stain in groups A and B compared to group C was obtained. Conclusions: Our results suggest that, the addition of PRP to ASCs enhances bone formation after 3 months and may be clinically effective in accelerating postsurgical healing in both periodontal and maxillofacial surgical applications. PMID:24298335

  6. Columnar metaplasia in a surgical mouse model of gastro-esophageal reflux disease is not derived from bone marrow-derived cell.

    PubMed

    Aikou, Susumu; Aida, Junko; Takubo, Kaiyo; Yamagata, Yukinori; Seto, Yasuyuki; Kaminishi, Michio; Nomura, Sachiyo

    2013-09-01

    The incidence of esophageal adenocarcinoma has increased in the last 25 years. Columnar metaplasia in Barrett's mucosa is assumed to be a precancerous lesion for esophageal adenocarcinoma. However, the induction process of Barrett's mucosa is still unknown. To analyze the induction of esophageal columnar metaplasia, we established a mouse gastro-esophageal reflux disease (GERD) model with associated development of columnar metaplasia in the esophagus. C57BL/6 mice received side-to-side anastomosis of the esophagogastric junction with the jejunum, and mice were killed 10, 20, and 40 weeks after operation. To analyze the contribution of bone marrow-derived cells to columnar metaplasia in this surgical GERD model, some mice were transplanted with GFP-marked bone marrow after the operation. Seventy-three percent of the mice (16/22) showed thickened mucosa in esophagus and 41% of mice (9/22) developed columnar metaplasia 40 weeks after the operation with a mortality rate of 4%. Bone marrow-derived cells were not detected in columnar metaplastic epithelia. However, scattered epithelial cells in the thickened squamous epithelia in regions of esophagitis did show bone marrow derivation. The results demonstrate that reflux induced by esophago-jejunostomy in mice leads to the development of columnar metaplasia in the esophagus. However, bone marrow-derived cells do not contribute directly to columnar metaplasia in this mouse model. © 2013 Japanese Cancer Association.

  7. Fixation of revision implants is improved by a surgical technique to crack the sclerotic bone rim.

    PubMed

    Kold, Søren; Bechtold, Joan E; Mouzin, Olivier; Elmengaard, Brian; Chen, Xinqian; Søballe, Kjeld

    2005-03-01

    Revision joint replacement has poorer outcomes compared with primary joint replacement, and these poor outcomes have been associated with poorer fixation. We investigated a surgical technique done during the revision operation to improve access from the marrow space to the implant interface by locally cracking the sclerotic bone rim that forms during aseptic loosening. Sixteen implants were inserted bilaterally by distal femur articulation of the knee joint of eight dogs, using our controlled experimental model that replicates the revision setting (sclerotic bone rim, dense fibrous tissue, macrophages, elevated cytokines) by pistoning a loaded 6.0-mm implant 500 microm into the distal femur with particulate PE. At 8 weeks, one of two revision procedures was done. Both revision procedures included complete removal of the membrane, scraping, lavaging, and inserting a revision plasma-spray Ti implant. The crack revision procedure also used a splined tool to circumferentially locally perforate the sclerotic bone rim before insertion of an identical revision implant. Superior fixation was achieved with the cracking procedure in this experimental model. Revision implants inserted with the rim cracking procedure had a significantly higher pushout strength (fivefold median increase) and energy to failure (sixfold median increase), compared with the control revision procedure. Additional evaluation is needed of local perforation of sclerotic bone rim as a simple bone-sparing means to improve revision implant fixation and thereby increase revision implant longevity.

  8. The biomechanics of plate fixation of periprosthetic femoral fractures near the tip of a total hip implant: cables, screws, or both?

    PubMed

    Shah, S; Kim, S Y R; Dubov, A; Schemitsch, E H; Bougherara, H; Zdero, R

    2011-09-01

    Femoral shaft fractures after total hip arthroplasty (THA) remain a serious problem, since there is no optimal surgical repair method. Virtually all studies that examined surgical repair methods have done so clinically or experimentally. The present study assessed injury patterns computationally by developing three-dimensional (3D) finite element (FE) models that were validated experimentally. The investigation evaluated three different constructs for the fixation of Vancouver B1 periprosthetic femoral shaft fractures following THA. Experimentally, three bone plate repair methods were applied to a synthetic femur with a 5 mm fracture gap near the tip of a total hip implant. Repair methods were identical distal to the fracture gap, but used cables only (construct A), screws only (construct B), or cables plus screws (construct C) proximal to the fracture gap. Specimens were oriented in 15 degrees adduction to simulate the single-legged stance phase of walking, subjected to 1000 N of axial force, and instrumented with strain gauges. Computationally, a linearly elastic and isotropic 3D FE model was developed to mimic experiments. Results showed excellent agreement between experimental and FE strains, yielding a Pearson linearity coefficient, R2, of 0.92 and a slope for the line of best data fit of 1.06. FE-computed axial stiffnesses were 768 N/mm (construct A), 1023 N/mm (construct B), and 1102 N/mm (construct C). FE surfaces stress maps for cortical bone showed Von Mises stresses, excluding peaks, of 0-8 MPa (construct A), 0-15 MPa (construct B), and 0-20 MPa (construct C). Cables absorbed the majority of load, followed by the plates and then the screws. Construct A yielded peak stress at one of the empty holes in the plate. Constructs B and C had similar bone stress patterns, and can achieve optimal fixation.

  9. Numerical and experimental study on the wave attenuation in bone--FDTD simulation of ultrasound propagation in cancellous bone.

    PubMed

    Nagatani, Yoshiki; Mizuno, Katsunori; Saeki, Takashi; Matsukawa, Mami; Sakaguchi, Takefumi; Hosoi, Hiroshi

    2008-11-01

    In cancellous bone, longitudinal waves often separate into fast and slow waves depending on the alignment of bone trabeculae in the propagation path. This interesting phenomenon becomes an effective tool for the diagnosis of osteoporosis because wave propagation behavior depends on the bone structure. Since the fast wave mainly propagates in trabeculae, this wave is considered to reflect the structure of trabeculae. For a new diagnosis method using the information of this fast wave, therefore, it is necessary to understand the generation mechanism and propagation behavior precisely. In this study, the generation process of fast wave was examined by numerical simulations using elastic finite-difference time-domain (FDTD) method and experimental measurements. As simulation models, three-dimensional X-ray computer tomography (CT) data of actual bone samples were used. Simulation and experimental results showed that the attenuation of fast wave was always higher in the early state of propagation, and they gradually decreased as the wave propagated in bone. This phenomenon is supposed to come from the complicated propagating paths of fast waves in cancellous bone.

  10. Surgical Treatment of the Atrophic Mandibular Fractures by Locked Plates Systems: Our Experience and a Literature Review

    PubMed Central

    Novelli, Giorgio; Sconza, Cristiano; Ardito, Emanuela; Bozzetti, Alberto

    2012-01-01

    The management of atrophic mandibular fractures in edentulous patients represents an insidious issue for the maxillofacial surgeon due to the biological and biomechanical conditions that are unfavorable for fracture fixation and bone healing. The purpose of this study was to evaluate the results of the treatment of atrophic mandibular fractures and to compare the outcomes of different plating systems used for stabilization. We selected a study group of 16 patients with fractures of completely edentulous atrophic mandibles who were treated in our department between 2004 and 2010. All patients were surgically treated by open reduction and internal rigid fixation using 2.0-mm large-profile locking and 2.4-mm locking bone plates. All patients achieved a complete fracture healing and fast functional recovery of mandibular movements without intraoperative or postoperative surgical complications. The results of our study demonstrated the efficacy of this type of treatment in association with a low postoperative complication rate, a reduction in the recovery time, and the possibility to have an immediately functional rehabilitation. There were very similar results using each of the two bone plating methods considered: no case had hardware failure or nonunion of the fracture. The 2.0-mm large locking plate is thinner, exposes through the soft tissues less frequently, and is much easier to shape and adapt to the mandibular anatomy. However, the 2.4-mm locking plate system still represents the reference hardware in the condition of severe bone atrophy. PMID:23730420

  11. Sexual function in adolescent and young adult survivors of lower extremity bone tumors.

    PubMed

    Barrera, Maru; Teall, Tanya; Barr, Ronald; Silva, Mariana; Greenberg, Mark

    2010-12-15

    Improving survival rates and new surgical options have led to increased interest regarding late effects and quality of life in adolescent and young adult survivors of bone cancers, including their sexual functioning. This study investigated sexual functioning in adolescent and young adult survivors of lower limb bone tumors, in relation to surgical treatments, gender differences, depressive symptoms, global self worth, and physical disability. Twenty-eight participants (age range 18-32 years) completed measures of gender specific sexual function, depressive symptoms, global self worth, and physical disability. For analysis, surgical intervention was grouped into limb sparing surgeries (LS; allograft fusion and endoprosthesis) and amputation or Van Nes rotationplasty (AMP). Male survivors reported significantly higher scores than females on total sexual function scores (P = 0.050), sexual drive (P = 0.002), and frequency of sexual thoughts, fantasies or erotic dreams (P = 0.021). Men also reported significantly better physical functioning scores than women (P = 0.012). LS scored significantly lower on frequency of sexual thoughts, fantasies and erotic dreams (P = 0.048) and frequency of sexual experiences (P = 0.016) compared with AMP. In addition, LS reported significantly more depressive symptoms scores (P = 0.004) and lower self worth scores (P = 0.037), than AMP. These results suggest that male survivors of lower extremity bone tumors experience better sexual functioning than women. Survivors of limb sparing surgeries struggle with sexual function, depressive symptoms, and poor self-perception compared to Van Nes rotationplasty and amputation survivors. Copyright © 2010 Wiley-Liss, Inc.

  12. Is The Late Mandibular Fracture From Third Molar Extraction a Risk Towards Malpractice? Case Report with the Analysis of Ethical and Legal Aspects.

    PubMed

    Dos Santos Silva, Weuler; Silveira, Rubens Jorge; de Araujo Andrade, Michelle Gouveia Benicio; Franco, Ademir; Silva, Rhonan Ferreira

    2017-01-01

    The present study reports a case of late mandibular fracture due to third molar extraction and highlights the inherent clinical, ethical and legal aspects related to this surgical complication. A female patient underwent surgical procedure for the extraction of the mandibular right third molar. Two days after the surgery the patient reported pain and altered occlusion in the right side of the mandible. After clinical and radiographic re-examination, the diagnosis of late mandibular fracture was established. A second surgery, under general anaesthesia, was performed for the fixation of the mandibular bone. The fractured parts were reduced and fixed with locking plate systems and 2 mm screws following load-sharing principles. The masticatory function showed optimal performance within 7 and 21 days after the surgery. Complete bone healing was observed within 1 year of follow-up. For satisfactory surgical outcomes, adequate surgical planning and techniques must be performed. Signed informed consents explaining the risks and benefits of the treatment must be used to avoid ethical and legal disputes in dentistry.

  13. MRI induced torque and demagnetization in retention magnets for a bone conduction implant.

    PubMed

    Jansson, Karl-Johan Fredén; Håkansson, Bo; Reinfeldt, Sabine; Taghavi, Hamidreza; Eeg-Olofsson, Måns

    2014-06-01

    Performing magnetic resonance imaging (MRI) examinations in patients who use implantable medical devices involve safety risks both for the patient and the implant. Hearing implants often use two permanent magnets, one implanted and one external, for the retention of the external transmitter coil to the implanted receiver coil to achieve an optimal signal transmission. The implanted magnet is subjected to both demagnetization and torque, magnetically induced by the MRI scanner. In this paper, demagnetization and a comparison between measured and simulated induced torque is studied for the retention magnet used in a bone conduction implant (BCI) system. The torque was measured and simulated in a uniform static magnetic field of 1.5 T. The magnetic field was generated by a dipole electromagnet and permanent magnets with two different types of coercive fields were tested. Demagnetization and maximum torque for the high coercive field magnets was 7.7% ± 2.5% and 0.20 ± 0.01 Nm, respectively and 71.4% ± 19.1% and 0.18 ± 0.01 Nm for the low coercive field magnets, respectively. The simulated maximum torque was 0.34 Nm, deviating from the measured torque in terms of amplitude, mainly related to an insufficient magnet model. The BCI implant with high coercive field magnets is believed to be magnetic resonance (MR) conditional up to 1.5 T if a compression band is used around the skull to fix the implant. This is not approved and requires further investigations, and if removal of the implant is needed, the surgical operation is expected to be simple.

  14. Surgical treatment of refractory tibial stress fractures in elite dancers: a case series.

    PubMed

    Miyamoto, Ryan G; Dhotar, Herman S; Rose, Donald J; Egol, Kenneth

    2009-06-01

    Treatment of tibial stress fractures in elite dancers is centered on rest and activity modification. Surgical intervention in refractory cases has important implications affecting the dancers' careers. Refractory tibial stress fractures in dancers can be treated successfully with drilling and bone grafting or intramedullary nailing. Case series; Level of evidence, 4. Between 1992 and 2006, 1757 dancers were evaluated at a dance medicine clinic; 24 dancers (1.4%) had 31 tibial stress fractures. Of that subset, 7 (29.2%) elite dancers with 8 tibial stress fractures were treated operatively with either intramedullary nailing or drilling and bone grafting. Six of the patients were followed up closely until they were able to return to dance. One patient was available only for follow-up phone interview. Data concerning their preoperative treatment regimens, operative procedures, clinical union, radiographic union, and time until return to dance were recorded and analyzed. The mean age of the surgical patients at the time of stress fracture was 22.6 years. The mean duration of preoperative symptoms before surgical intervention was 25.8 months. Four of the dancers were male and 3 were female. All had failed nonoperative treatment regimens. Five patients (5 tibias) underwent drilling and bone grafting of the lesion, and 2 patients (3 tibias) with completed fractures or multiple refractory stress fractures underwent intramedullary nailing. Clinical union was achieved at a mean of 6 weeks and radiographic union at 5.1 months. Return to full dance activity was at an average of 6.5 months postoperatively. Surgical intervention for tibial stress fractures in dancers who have not responded to nonoperative management allowed for resolution of symptoms and return to dancing with minimal morbidity.

  15. Intrapetrous Internal Carotid Artery: Evaluation of Exposure, Mobilization and Surgical Maneuvers Feasibility from a Retrosigmoid Approach in a Cadaveric Model.

    PubMed

    Scerrati, Alba; Ercan, Serdar; Wu, Pengfei; Zhang, Jun; Ammirati, Mario

    2016-07-01

    To provide a quantification of the exposure of the vertical and horizontal segments of the intrapetrous carotid artery (IPCA) and to evaluate the possibilities of its mobilization and of performing surgical maneuvers on it using the retrosigmoid approach. Twelve surgical dissections were performed bilaterally on 6 fresh cadavers. Predissection computed tomography (CT) scans with bone fiducials for intraoperative navigation were acquired. A retrosigmoid craniectomy was performed. The inframeatal space was drilled, the horizontal (HoIPCA) and vertical (VeIPCA) segments of the IPCA were exposed, and their measurements were recorded. The carotid canal was enlarged, the artery was carefully detached from the bone, and a vessel loop was inserted in order to mobilize its horizontal segment. Afterwards we performed different surgical maneuvers: We inflated a 5-French Fogarty balloon to compress the IPCA and repaired a 7-mm arteriotomy with a running suture. Specimens underwent a new CT scan to evaluate the amount of bone removal and the integrity of the inner ear structures. The HoIPCA and VeIPCA were exposed and anatomically preserved in all specimens without injuring the surrounding neurovascular structures. The HoIPCA presented an average length of 24.89 mm (range: 19.41-31.47 mm), and the VeIPCA presented an average length of 10.07 mm (range: 8.92-11.58 mm). The possibility of IPCA mobilization and the feasibility of performing surgical maneuvers were demonstrated. Postdissection CT scan showed the preservation of inner ear structures. Exposure and mobilization of the IPCA using a retrosigmoid approach are feasible and could represent a viable option for the possibility of reaching a total resection of selected skull base tumors, even when involvement of the carotid canal is present. Published by Elsevier Inc.

  16. Comparison of Dental Panoramic Radiography and CBCT for Measuring Vertical Bone Height in Different Horizontal Locations of Posterior Mandibular Alveolar Process

    PubMed Central

    Shahidi, Shoaleh; Zamiri, Barbad; Abolvardi, Masoud; Akhlaghian, Marzieh; Paknahad, Maryam

    2018-01-01

    Statement of the Problem: Accurate measurement of the available bone height is an essential step in the pre-surgical phase of dental implantation. Panoramic radiography is a unique technique in the pre-surgical phase of dental implantations because of its low cost, relatively low-dose, and availability. Purpose: This article aimed to assess the reliability of dental panoramic radiographs in the accurate measurement of the vertical bone height with respect to the horizontal location of the alveolar crest. Materials and Method: 132 cone-beam computed tomography (CBCT) of the edentulous mandibular molar area and dental panoramic radiograph of 508 patients were selected. Exclusion criteria were bone abnormalities and detectable ideal information on each modality. The alveolar ridge morphology was categorized into 7 types according to the relative horizontal location of the alveolar crest to the mandibular canal based on CBCT findings. The available bone height (ABH) was defined as the distance between the upper border of the mandibular canal and alveolar crest. One oral radiologist and one oral surgeon measured the available bone height twice on each modality with a 7-dayinterval. Results: We found a significant correlation between dental panoramic radiographs and cone-beam computed tomography values (ICC=0.992, p< 0.001). A positive correlation between the horizontal distance of the alveolar crest to the mandibular canal and measured differences between two radiographic modalities had been found (r=0.755, p< 0.001). For each single unit of increase in the horizontal distance of the alveolar crest to the mandibular canal, dental panoramic radiographs showed 0.87 unit of overestimation (p< 0.001). Conclusion: Dental panoramic radiographs can be employed safely in the pre-surgical phase of dental implantation in posterior alveolus of mandible, especially in routine and simple cases. PMID:29854881

  17. Current practice of antibiotic prophylaxis for surgical fixation of closed long bone fractures: a survey of 297 members of the Orthopaedic Trauma Association.

    PubMed

    Gans, Itai; Jain, Amit; Sirisreetreerux, Norachart; Haut, Elliott R; Hasenboehler, Erik A

    2017-01-01

    The risk of postoperative surgical site infection after long bone fracture fixation can be decreased with appropriate antibiotic use. However, there is no agreement on the superiority of a single- or multiple-dose perioperative regimen of antibiotic prophylaxis. The purpose of this study is to determine the following: 1) What are the current practice patterns of orthopaedic trauma surgeons in using perioperative antibiotics for closed long bone fractures? 2) What is the current knowledge of published antibiotic prophylaxis guidelines among orthopaedic trauma surgeons? 3) Are orthopaedic surgeons willing to change their current practices? A questionnaire was distributed via email between September and December 2015 to 955 Orthopaedic Trauma Association members, of whom 297 (31%) responded. Most surgeons (96%) use cefazolin as first-line infection prophylaxis. Fifty-nine percent used a multiple-dose antibiotic regimen, 39% used a single-dose regimen, and 2% varied this decision according to patient factors. Thirty-six percent said they were unfamiliar with Centers for Disease Control and Prevention (CDC) antibiotic prophylaxis guidelines; only 30% were able to select the correct CDC recommendation from a multiple-choice list. However, 44% of surgeons said they followed CDC recommendations. Fifty-six percent answered that a single-dose antibiotic prophylaxis regimen was not inferior to a multiple-dose regimen. If a level-I study comparing a single preoperative dose versus multiple perioperative antibiotic dosing regimen for treatment of closed long bone fractures were published, most respondents (64%) said they would fully follow these guidelines, and 22% said they would partially change their practice to follow these guidelines. There is heterogeneity in the use of single- versus multiple-dose antibiotic prophylaxis for surgical repair of closed long bone fractures. Many surgeons were unsure of current evidence-based recommendations regarding perioperative antibiotic use. Most respondents indicated they would be receptive to high-level evidence regarding the single- versus multiple-dose perioperative prophylactic antibiotics for the treatment of closed long bone fractures.

  18. Using Free Navigation Reference Points and Prefabricated Bone Plates for Zygoma Fracture Model Surgeries.

    PubMed

    Wang, Tien-Hsiang; Ma, Hsu; Tseng, Ching-Shiow; Chou, Yi-Hong; Cai, Kun-Lin

    Surgical navigation systems have been an important tool in maxillofacial surgery, helping surgeons create a presurgical plan, locate lesions, and provide guidance. For secondary facial bone reductions, a good presurgical plan and proper execution are the key to success. Previous studies used predetermined markers and screw holes as navigation references; however, unexpected situations may occur, making the predetermined surgical plan unreliable. Instead of determining positions preoperatively, this study proposes a method that surgeons can use intraoperatively to choose surface markers in a more flexible manner. Eight zygomatic fractures were created in four skull models, and preoperative computed tomography (CT) image data were imported into a self-developed navigation program for presurgical planning. This program also calculates the ideal positions of navigation references points for screw holes. During reduction surgery, markers on fractured bone are selected, registered, and calculated as free navigation reference points (FNRPs). The surface markers and FNRPs are used to monitor the position of the dislocated bone. Titanium bone plates were prefabricated on stereolithography models for osteosynthesis. Two reductions with only FNRPs, as well as six reductions with FNRPs and prefabricated bone plates, were successfully performed. Postoperative CT data were obtained, and surgical errors in the six-reduction group were evaluated. The average deviation from the screw hole drilling positions was 0.92 ± 0.38 mm. The average deviation included displacement and rotation of the zygomas. The mean displacement was 0.83 ± 0.38 mm, and the average rotations around the x, y, and z axes were 0.66 ± 0.59°, 0.77 ± 0.54°, and 0.79 ± 0.42°, respectively. The results show that combining presurgical planning and the developed navigation program to generate FNRPs for assisting in secondary zygoma reduction is an accurate and practical method. Further study is necessary to prove its clinical value.

  19. Bone fracture healing in mechanobiological modeling: A review of principles and methods.

    PubMed

    Ghiasi, Mohammad S; Chen, Jason; Vaziri, Ashkan; Rodriguez, Edward K; Nazarian, Ara

    2017-06-01

    Bone fracture is a very common body injury. The healing process is physiologically complex, involving both biological and mechanical aspects. Following a fracture, cell migration, cell/tissue differentiation, tissue synthesis, and cytokine and growth factor release occur, regulated by the mechanical environment. Over the past decade, bone healing simulation and modeling has been employed to understand its details and mechanisms, to investigate specific clinical questions, and to design healing strategies. The goal of this effort is to review the history and the most recent work in bone healing simulations with an emphasis on both biological and mechanical properties. Therefore, we provide a brief review of the biology of bone fracture repair, followed by an outline of the key growth factors and mechanical factors influencing it. We then compare different methodologies of bone healing simulation, including conceptual modeling (qualitative modeling of bone healing to understand the general mechanisms), biological modeling (considering only the biological factors and processes), and mechanobiological modeling (considering both biological aspects and mechanical environment). Finally we evaluate different components and clinical applications of bone healing simulation such as mechanical stimuli, phases of bone healing, and angiogenesis.

  20. The application of 3D printed surgical guides in resection and reconstruction of malignant bone tumor.

    PubMed

    Wang, Fengping; Zhu, Jun; Peng, Xuejun; Su, Jing

    2017-10-01

    The clinical value of 3D printed surgical guides in resection and reconstruction of malignant bone tumor around the knee joint were studied. For this purpose, a sample of 66 patients from October 2013 to October 2015 were randomly selected and further divided into control group and observation group, each group consisted of 33 cases. The control group was treated by conventional tumor resection whereas, in the observation group, the tumor was resected with 3D printed surgical guide. However, reconstruction of tumor-type hinge prosthesis was performed in both groups and then the clinical effect was compared. Results show that there was no significant difference in the operation time between the two groups (p>0.05). However, the blood loss, resection length and complication rate were found significantly lower in the observation group than in the control group (p<0.05). The rate of negative margin and the recurrence rate in the 12-month follow-up (p>0.05) between two groups were statistically the same (p>0.05), whereas the Musculoskeletal Tumor Society (MSTS) score of the knee joint in the observation group was significantly better than that of the control group (p<0.05) after 1, 3, 6 and 12 months of the operation. Consequently, the 3D printed surgical guides can significantly improve the postoperative joint function after resection and reconstruction of malignant bone tumor around the knee joint and can reduce the incidence of complications.

Top