Thermographic analysis and autonomic response in the hands of patients with leprosy.
Cavalheiro, Aretusa Lopes; Costa, Debora Tacon da; Menezes, Ana Luiza Ferro de; Pereira, Janser Moura; Carvalho, Eliane Maria de
2016-01-01
Low temperatures and slow blood flow may result from peripheral neuropathy caused by leprosy, and the simple detection of cold fingers could already be a preliminary classification for these patients. To investigate whether infrared thermography would be able to measure this change in temperature in the hands of people with leprosy. The study assessed 17 leprosy patients who were under treatment at the National Reference Center for Sanitary Dermatology and Leprosy, Uberlândia/MG, and 15 people without leprosy for the control group. The infrared camera FLIR A325 and Therma CAM Researcher Professional 2.9 software were used to measure the temperature. The room was air-conditioned, maintaining the temperature at 25°C; the distance between the camera and the limb was 70 cm. The vasomotor reflex of patients was tested by a cold stress on the palm. The study showed a significant interaction between the clinical form of leprosy and temperature, where the control group and the borderline-borderline form revealed a higher initial temperature, while borderline-lepromatous and lepromatous leprosy showed a lower temperature. Regarding vasomotor reflex, lepromatous leprosy patients were unable to recover the initial temperature after cold stress, while those with the borderline-tuberculoid form not only recovered but exceeded the initial temperature. Thermography proved a potential tool to assist in the early detection of neuropathies, helping in the prevention of major nerve damage and the installation of deformities and disabilities that are characteristic of leprosy.
Environmental temperature affects the dynamics of ingestion in the nectivorous ant Camponotus mus.
Falibene, Agustina; Josens, Roxana
2014-12-01
Environmental temperature influences physiology and behavior in animals in general and is particularly determinant in ectotherms. Not least because temperature defines metabolism and body temperature, muscle activity in insects also strongly depends on this factor. Here, we analyzed how environmental temperature influences the dynamics of ingestion due to its effect on the sucking pump muscles in the nectivorous ants Camponotus mus. Feeding behavior and sucking pump activity during sucrose solution ingestion were first recorded in a natural environment in an urban setting throughout the day and in different seasons. Then, controlled temperature experiments were performed in the laboratory. In both situations, feeding time decreased and pumping frequency increased with temperature. However, different pumping frequencies under a same temperature were also observed in different seasons. Besides, in the laboratory, the volume of solution ingested increased with temperature. Consequently, intake rate increased when temperature rose. This change was exclusively promoted by a variation in the pumping frequency while volume taken in per pump contraction was not affected by temperature. In summary, environmental temperature modified the dynamics of ingestion and feeding behavior by directly affecting pumping frequency. Copyright © 2014 Elsevier Ltd. All rights reserved.
Evaluation of Ti-Zr-V (NEG) Thin Films for their pumping speed and pumping Capacity
NASA Astrophysics Data System (ADS)
Bansod, Tripti; Sindal, B. K.; Kumar, K. V. A. N. P. S.; Shukla, S. K.
2012-11-01
Deposition of NEG thin films onto the interior walls of the vacuum chambers is an advanced technique to convert a vacuum chamber from a gas source to an effective pump. These films offer considerably large pumping speed for reactive gases like CO, H2 etc. A UHV compatible pumping speed measurement system was developed in-house to measure the pumping speed of NEG coated chambers. To inject the fixed quantity of CO and H2 gas in pumping speed measurement set-up a calibrated leak was also developed. Stainless steel chambers were sputter coated with thin film of Ti-Zr-V getter material using varied parameters for different compositions and thickness. Pumping capacity which is a function of sorbed gas quantities was also studied at various activation temperatures. In order to optimize the activation temperature for maximum pumping speed for CO and H2, pumping speeds were measured at room temperature after activation at different temperatures. The experimental system detail, pumping performance of the NEG film at various activation temperatures and RGA analysis are presented.
Winkler, Bernhard; Heinisch, Paul P; Gahl, Brigitta; Aghlmandi, Soheila; Jenni, Hans Jörg; Carrel, Thierry P
2017-01-01
The pathophysiologic side effects of cardiopulmonary bypass have already been identified. Minimally invasive extracorporeal circulation technologies (MiECT) and off-pump coronary artery bypass graft surgery (OPCABG) aim to reduce these problems. This meta-analysis provides a comparison of MiECT and OPCABG in randomized and observational studies. A fully probabilistic, Bayesian approach of primary and secondary endpoints was conducted. MiECT does not give inferior results when compared with OPCABG. However, there is a trend to borderline significantly higher blood loss in this group in randomized controlled trials. The question whether MiECT is equivalent to OPCABG can be answered with the affirmative, but long-term follow-up data are needed to detect any advantage over time. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.
AN EVALUATION OF PERSONAL SAMPLING PUMPS IN SUB-ZERO TEMPERATURES
Personal sampling pumps suitable for industrial hygiene surveys were evaluated to discover their characteristics as a function of temperature for temperatures between 25 and -50C. The pumps evaluated were significantly influenced by low temperatures. In general, most provided a s...
Light propagation in the micro-size capillary injected by high temperature liquid
NASA Astrophysics Data System (ADS)
Li, Yan-jun; Li, Edward; Xiao, Hai
2016-11-01
The high temperature liquid is injected into the micro-size capillary and its light propagation behavior is investigated. We focus on two different liquid pumping methods. The first method can pump the high temperature liquid tin into the micro-size capillary by using a high pressure difference system. After pumping, a single mode fiber (SMF) connected with the optical carrier based microwave interferometry (OCMI) system is used to measure different liquid tin levels in the micro-size capillary. The second method can pump the room temperature engine oil into the capillary by using a syringe pump. This method can avoid the air bubbles when the liquids are pumped into the capillary.
Measured Performance of a Low Temperature Air Source Heat Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
R.K. Johnson
2013-09-01
A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor “boosted heat pump” technology. The Low Temperature Heat Pump system operates with four increasing levels of capacity (heat output) as the outdoor temperature drops.
A novel high temperature superconducting magnetic flux pump for MRI magnets
NASA Astrophysics Data System (ADS)
Bai, Zhiming; Yan, Guo; Wu, Chunli; Ding, Shufang; Chen, Chuan
2010-10-01
This paper presents a kind of minitype magnetic flux pump made of high temperature superconductor. This kind of novel high temperature superconducting (HTS) flux pump has not any mechanical revolving parts or thermal switches. The excitation current of copper coils in magnetic pole system is controlled by a singlechip. The structure design and operational principle have been described. The operating performance of the new model magnetic flux pump has been preliminarily tested. The experiments show that the maximum pumping current is approximately 200 A for Bi2223 flux pump and 80 A for MgB 2 flux pump operating at 20 K. By comparison, it is discovered that the operating temperature range is wider, the ripple is smaller and the pumping frequency is higher in Bi2223 flux pump than those in MgB 2 flux pump. These results indicate that the newly developed Bi2223 magnetic flux pump may efficiently compensate the magnetic field decay in HTS magnet and make the magnet operate in persistent current mode, this point is significant to the magnetic resonance imaging (MRI) magnets. This new flux pump is under construction presently. It is expected that the Bi2223 flux pump would be applied to the superconducting MRI magnets by further optimizing structure and improving working process.
Warming of infusion syringes caused by electronic syringe pumps.
Cornelius, A; Frey, B; Neff, T A; Gerber, A C; Weiss, M
2003-05-01
To evaluate inadvertent warming of the infusion syringe in four different types of electronic syringe pumps. Ambient temperature and syringe surface temperature were simultaneously measured by two electronic temperature probes in four different models of commercially available syringe pumps. Experiments were performed at an infusion rate of 1 ml h(-1) using both battery-operated and main power-operated pumps. Measurements were repeated four times with two pumps from each of the four syringe pump types at a room temperature of approximately 23 degrees C. Differences among the four syringe pump brands regarding ambient to syringe temperature gradient were compared using ANOVA. A P-value of less than 0.05 was considered statistically significant. Syringe warming differed significantly between the four syringe brands for both the battery-operated and main power-operated mode (ANOVA, P< 0.001 for both modes). Individual differences between syringe surface and ambient temperature ranged from 0.3 to 1.9 degrees C for battery operation and from 0.5 to 11.2 degrees C during main-power operation. Infusion solutions can be significantly warmed by syringe pumps. This has potential impact on bacterial growth and the stability of drug solutions and blood products infused, as well as on the susceptibility to hydrostatic pressure changes within the infusion syringe.
Analytical thermal model for end-pumped solid-state lasers
NASA Astrophysics Data System (ADS)
Cini, L.; Mackenzie, J. I.
2017-12-01
Fundamentally power-limited by thermal effects, the design challenge for end-pumped "bulk" solid-state lasers depends upon knowledge of the temperature gradients within the gain medium. We have developed analytical expressions that can be used to model the temperature distribution and thermal-lens power in end-pumped solid-state lasers. Enabled by the inclusion of a temperature-dependent thermal conductivity, applicable from cryogenic to elevated temperatures, typical pumping distributions are explored and the results compared with accepted models. Key insights are gained through these analytical expressions, such as the dependence of the peak temperature rise in function of the boundary thermal conductance to the heat sink. Our generalized expressions provide simple and time-efficient tools for parametric optimization of the heat distribution in the gain medium based upon the material and pumping constraints.
A blackbody radiation-pumped CO2 laser experiment
NASA Technical Reports Server (NTRS)
Christiansen, W. H.; Insuik, R. J.; Deyoung, R. J.
1982-01-01
Thermal radiation from a high temperature oven was used as an optical pump to achieve lasing from CO2 mixtures. Laser output as a function of blackbody temperature and gas conditions is described. This achievement represents the first blackbody cavity pumped laser and has potential for solar pumping.
Jet pump-drive system for heat removal
NASA Technical Reports Server (NTRS)
French, J. R. (Inventor)
1985-01-01
A jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A TEMP, responsive to the heat from the coolant in the secondary flow path, automatically pumps the withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature. At this lower temperature, the TEMP/jet jump combination ceases its circulation boosting operation. The TEMP/jet pump combination is automatic, self-regulating and provides an emergency pumping system free of moving parts.
Jet pump-drive system for heat removal
NASA Technical Reports Server (NTRS)
French, James R. (Inventor)
1987-01-01
The invention does away with the necessity of moving parts such as a check valve in a nuclear reactor cooling system. Instead, a jet pump, in combination with a TEMP, is employed to assure safe cooling of a nuclear reactor after shutdown. A main flow exists for a reactor coolant. A point of withdrawal is provided for a secondary flow. A TEMP, responsive to the heat from said coolant in the secondary flow path, automatically pumps said withdrawn coolant to a higher pressure and thus higher velocity compared to the main flow. The high velocity coolant is applied as a driver flow for the jet pump which has a main flow chamber located in the main flow circulation pump. Upon nuclear shutdown and loss of power for the main reactor pumping system, the TEMP/jet pump combination continues to boost the coolant flow in the direction it is already circulating. During the decay time for the nuclear reactor, the jet pump keeps running until the coolant temperature drops to a lower and safe temperature where the heat is no longer a problem. At this lower temperature, the TEMP/jet pump combination ceases its circulation boosting operation. When the nuclear reactor is restarted and the coolant again exceeds the lower temperature setting, the TEMP/jet pump automatically resumes operation. The TEMP/jet pump combination is thus automatic, self-regulating and provides an emergency pumping system free of moving parts.
NASA Technical Reports Server (NTRS)
Powell, A. H.; Amos, J. C.; Ehde, C. L.; Gahan, J. W.
1972-01-01
A three-phase helical induction electromagnetic pump, designed for the boiler-feed pump of a potassium Rankine-cycle space power system, was built and tested. The pump was tested over a range of potassium temperatures from 900 to 1400 F, flow rates from 0.75 to 4.85 lb/sec, developed pressures up to 340 psi, net positive suction heads (NPSH) from 1 to 22 psi, and NaK coolant temperatures from 800 to 950 F. The maximum efficiency at the pump design point of 3.25 lb/sec flow rate, 240 psi developed pressure, 1000 F potassium inlet temperature, and 800 F NaK coolant temperature was 16.3 percent. The tests also showed successful operation of the pump at an NPSH as low as 1.5 psi without cavitating.
Thermomechanical piston pump development
NASA Technical Reports Server (NTRS)
Sabelman, E. E.
1971-01-01
A thermally powered reciprocating pump has been devised to replace or augment an electric pump for the transport of temperature-control fluid on the Thermoelectric Outer Planet Spacecraft (TOPS). The thermally powered pump operates cyclically by extracting heat energy from the fluid by means of a vapor-pressure expansion system and by using the heat to perform the mechanical work of pumping. A feasibility test unit has been constructed to provide an output of 7 cu in during a 10- to 100-second cycle. It operates with a fluid input temperature of 200 to 300 F and a heat sink temperature of 0 to 30 F.
NASA Technical Reports Server (NTRS)
Dobson, Chris C.
1998-01-01
Sodium fluorescence induced by a narrow bandwidth tunable laser has been used to measure temperature, pressure, axial velocity and species concentrations in wind tunnels, rocket engine exhausts and the upper atmosphere. Optical pumping of the ground states of the sodium, however, can radically alter the shape of the laser induced fluorescence excitation spectrum, complicating such measurements. Here a straightforward extension of rate equations originally proposed to account for the features of the pumped spectrum is to make temperature measurements from spectra taken in pumped vapor. Also determined from the spectrum is the relative fluorescence cycle number, which has application to measurement of diffusion rate and transverse flow velocity. The accuracy of both the temperature and cycle-number measurements is comparable with that of temperature measurements made in the absence of pumping.
Han, Xiahui; Li, Jianlang
2014-11-01
The transient temperature evolution in the gain medium of a continuous wave (CW) end-pumped passively Q-switched microchip (PQSM) laser is analyzed. By approximating the time-dependent population inversion density as a sawtooth function of time and treating the time-dependent pump absorption of a CW end-pumped PQSM laser as the superposition of an infinite series of short pumping pulses, the analytical expressions of transient temperature evolution and distribution in the gain medium for four- and three-level laser systems, respectively, are given. These analytical solutions are applied to evaluate the transient temperature evolution and distribution in the gain medium of CW end-pumped PQSM Nd:YAG and Yb:YAG lasers.
Time dependent temperature distribution in pulsed Ti:sapphire lasers
NASA Technical Reports Server (NTRS)
Buoncristiani, A. Martin; Byvik, Charles E.; Farrukh, Usamah O.
1988-01-01
An expression is derived for the time dependent temperature distribution in a finite solid state laser rod for an end-pumped beam of arbitrary shape. The specific case of end pumping by circular (constant) or Gaussian beam is described. The temperature profile for a single pump pulse and for repetitive pulse operation is discussed. The particular case of the temperature distribution in a pulsed titanium:sapphire rod is considered.
Engineering: Liquid metal pumped at a record temperature
NASA Astrophysics Data System (ADS)
Lambrinou, Konstantina
2017-10-01
Although liquid metals are effective fluids for heat transfer, pumping them at high temperatures is limited by their corrosiveness to solid metals. A clever pump design addresses this challenge using only ceramics. See Article p.199
Microfluidic Pumps Containing Teflon [Trademark] AF Diaphragms
NASA Technical Reports Server (NTRS)
Willis, Peter; White, Victor; Grunthaner, Frank; Ikeda, Mike; Mathies, Richard A.
2009-01-01
Microfluidic pumps and valves based on pneumatically actuated diaphragms made of Teflon AF polymers are being developed for incorporation into laboratory-on-a-chip devices that must perform well over temperature ranges wider than those of prior diaphragm-based microfluidic pumps and valves. Other potential applications include implanted biomedical microfluidic devices, wherein the biocompatability of Teflon AF polymers would be highly advantageous. These pumps and valves have been demonstrated to function stably after cycling through temperatures from -125 to 120 C. These pumps and valves are intended to be successors to similar prior pumps and valves containing diaphragms made of polydimethylsiloxane (PDMS) [commonly known as silicone rubber]. The PDMS-containing valves ae designed to function stably only within the temperature range from 5 to 80 C. Undesirably, PDMS membranes are somwehat porous and retain water. PDMS is especially unsuitable for use at temperatures below 0 C because the formation of ice crystals increases porosity and introduces microshear.
Sensitivity of viscosity Arrhenius parameters to polarity of liquids
NASA Astrophysics Data System (ADS)
Kacem, R. B. H.; Alzamel, N. O.; Ouerfelli, N.
2017-09-01
Several empirical and semi-empirical equations have been proposed in the literature to estimate the liquid viscosity upon temperature. In this context, this paper aims to study the effect of polarity of liquids on the modeling of the viscosity-temperature dependence, considering particularly the Arrhenius type equations. To achieve this purpose, the solvents are classified into three groups: nonpolar, borderline polar and polar solvents. Based on adequate statistical tests, we found that there is strong evidence that the polarity of solvents affects significantly the distribution of the Arrhenius-type equation parameters and consequently the modeling of the viscosity-temperature dependence. Thus, specific estimated values of parameters for each group of liquids are proposed in this paper. In addition, the comparison of the accuracy of approximation with and without classification of liquids, using the Wilcoxon signed-rank test, shows a significant discrepancy of the borderline polar solvents. For that, we suggested in this paper new specific coefficient values of the simplified Arrhenius-type equation for better estimation accuracy. This result is important given that the accuracy in the estimation of the viscosity-temperature dependence may affect considerably the design and the optimization of several industrial processes.
Variable temperature seat climate control system
Karunasiri, Tissa R.; Gallup, David F.; Noles, David R.; Gregory, Christian T.
1997-05-06
A temperature climate control system comprises a variable temperature seat, at least one heat pump, at least one heat pump temperature sensor, and a controller. Each heat pump comprises a number of Peltier thermoelectric modules for temperature conditioning the air in a main heat exchanger and a main exchanger fan for passing the conditioned air from the main exchanger to the variable temperature seat. The Peltier modules and each main fan may be manually adjusted via a control switch or a control signal. Additionally, the temperature climate control system may comprise a number of additional temperature sensors to monitor the temperature of the ambient air surrounding the occupant as well as the temperature of the conditioned air directed to the occupant. The controller is configured to automatically regulate the operation of the Peltier modules and/or each main fan according to a temperature climate control logic designed both to maximize occupant comfort during normal operation, and minimize possible equipment damage, occupant discomfort, or occupant injury in the event of a heat pump malfunction.
Temperature field study of hot water circulation pump shaft system
NASA Astrophysics Data System (ADS)
Liu, Y. Y.; Kong, F. Y.; Daun, X. H.; Zhao, R. J.; Hu, Q. L.
2016-05-01
In the process of engineering application under the condition of hot water circulation pump, problems of stress concentration caused by the temperature rise may happen. In order to study the temperature field in bearing and electric motor chamber of the hot water circulation pump and optimize the structure, in present paper, the model of the shaft system is created through CREO. The model is analyzed by ANSYS workbench, in which the thermal boundary conditions are applied to calculate, which include the calorific values from the bearings, the thermal loss from electric motor and the temperature from the transporting medium. From the result, the finite element model can reflect the distribution of thermal field in hot water circulation pump. Further, the results show that the maximum temperature locates in the bearing chamber.The theoretical guidance for the electric motor heat dissipation design of the hot water circulation pump can be achieved.
NASA Technical Reports Server (NTRS)
Dobson, Chris C.
1999-01-01
Sodium fluorescence induced by a narrow-bandwidth tunable laser has been used to measure temperature, pressure, axial velocity, and species concentrations in wind tunnels, rocket engine exhausts, and the upper atmosphere. Optical pumping of the ground states of the sodium, however, can radically alter the shape of the laser-induced fluorescence excitation spectrum, complicating such measurements. Here a straightforward extension of rate equations originally proposed to account for the features of the pumped spectrum is used to make temperature measurements from spectra taken in pumped vapor. Also determined from the spectrum is the relative fluorescence cycle number, which has application to measurement of diffusion rate and transverse flow velocity, The accuracy of both the temperature and the cycle-number measurements is comparable with that of temperature measurements made in the absence of pumping.
NASA Astrophysics Data System (ADS)
Huang, Jing; Wan, Yuan; Chen, Weibiao
2015-02-01
The influence of temperature and incident pump power on reabsorption loss is theoretically discussed. Temperature characteristic and reabsorption loss rate of a diode-pumped quasi-three-level 946 nm Nd:YAG laser are investigated. Reabsorption effect has a significant impact on laser performance. The results indicate that reabsorption loss increases as the working temperature rises and decreases with the increased incident pump power.
Comparative study of DPAL and XPAL systems and selection principal of parameters
NASA Astrophysics Data System (ADS)
Huang, Wei; Tan, Rongqing; Li, Zhiyong; Han, Gaoce; Li, Hui
2016-10-01
A theoretical model based on common pump structure is proposed to analyze the laser output characteristics of DPAL (Diode pumped alkali vapor laser) and XPAL (Exciplex pumped alkali laser) in this paper. The model predicts that an optical-to-optical efficiency approaching 80% can be achieved for continuous-wave four- and five-XPAL systems with broadband pumping which is several times of pumped linewidth for DPAL. Operation parameters including pumped intensity, temperature, cell' s length, mixed gas concentration, pumped linewidth and output mirror reflectivity are analyzed for DPAL and XPAL systems basing on the kinetic model. The result shows a better performance in Cs-Ar XPAL laser with requirements of relatively high Ar concentration, high pumped intensity and high temperature. Comparatively, for Cs-DPAL laser, lower temperature and lower pumped intensity should be acquired. In addition, the predictions of selection principal of temperature and cell's length are also presented. The conception of the equivalent "alkali areal density" is proposed in this paper. It is defined as the product of the alkali density and cell's length. The result shows that the output characteristics of DPAL (or XPAL) system with the same alkali areal density but different temperatures turn out to be equal. It is the areal density that reflects the potential of DPAL or XPAL systems directly. A more detailed analysis of similar influences of cavity parameters with the same areal density is also presented. The detailed results of continuous-wave DPAL and XPAL performances as a function of pumped laser linewidth and mixed gas pressure are presented along with an analysis of influences of output coupler.
Advanced high-temperature electromagnetic pump
NASA Technical Reports Server (NTRS)
Gahan, J. W.; Powell, A. H.
1972-01-01
Three phase helical, electromagnetic induction pump for use as boiler feed pump in potassium Rankine-cycle power system is described. Techniques for fabricating components of pump are discussed. Specifications of pump are analyzed.
Vertical climatic belts in the Tatra Mountains in the light of current climate change
NASA Astrophysics Data System (ADS)
Łupikasza, Ewa; Szypuła, Bartłomiej
2018-04-01
The paper discusses temporal changes in the configuration of vertical climatic belts in the Tatra Mountains as a result of current climate change. Meteorological stations are scarce in the Tatra Mountains; therefore, we modelled decadal air temperatures using existing data from 20 meteorological stations and the relationship between air temperature and altitude. Air temperature was modelled separately for northern and southern slopes and for convex and concave landforms. Decadal air temperatures were additionally used to delineate five climatic belts previously distinguished by Hess on the basis of threshold values of annual air temperature. The spatial extent and location of the borderline isotherms of 6, 4, 2, 0, and - 2 °C for four decades, including 1951-1960, 1981-1990, 1991-2000, and 2001-2010, were compared. Significant warming in the Tatra Mountains, uniform in the vertical profile, started at the beginning of the 1980s and led to clear changes in the extent and location of the vertical climatic belts delineated on the basis of annual air temperature. The uphill shift of the borderline isotherms was more prominent on southern than on northern slopes. The highest rate of changes in the extent of the climatic belts was found above the isotherm of 0 °C (moderately cold and cold belts). The cold belt dramatically diminished in extent over the research period.
1.88 Micrometers InGaAsP Pumped, Room Temperature Ho: LuAG Laser
NASA Technical Reports Server (NTRS)
Barnes, Norman P.; Amzajerdian, Farzin; Reichle, Donald J.; Busch, George; Leisher, Paul
2009-01-01
A room temperature, directly diode pumped Ho:LuAG laser oscillated for the first time. Direct pumping of the Ho upper laser manifold maximizes efficiency, minimizes heating, and eliminates Ho:Tm energy sharing. Design and performance are presented.
NASA Astrophysics Data System (ADS)
Maharjan, Madan
Groundwater response to stream stage fluctuations was studied using a year-long time series of stream stage and well heads in Glen Dale and New Martinsville, WV. Stream stage fluctuations exerted primary control over groundwater levels, especially during high flows. The location and operation of river pools created by dams alter groundwater flow paths and velocities. Aquifers are more prone to surface water infiltration in the upper reaches of pools than in lower reaches. Aquifer diffusivity is heterogeneous within and between the two sites. Temperature fluctuations were observed for 2.5 years in 14 wells in three alluvial aquifers. Temperature signals have 2 components corresponding to pump-on and pump-off periods. Both components vary seasonality at different magnitudes. While pump-off temperatures fluctuated up to 3.8o C seasonally, short-term temperature shifts induced by turning the pump on were 0.2 to 2.5o C. Pumping-induced temperature shifts were highest in magnitude in summer and winter. Groundwater temperature lagged behind that of surface water by approximately six months. Pumping induced and seasonal temperature shifts were spatially and temporally complex but indicate stream exfiltration is a major driver for a number of these wells. Numerical simulation of aquifer response to pumping show different conditions before and after well-field development. During pre-development, the stream was losing at high flow and gaining at low flow. During post-development, however, the stream was losing at high flow and spatially variable at low flow. While bank storage gained only during high stage, stream exfiltration occurred year-round. Pumping induced stream exfiltration by creating an extensive cone of depression beneath the stream in both upstream and downstream directions. Spatially and temporally variable groundwater-surface water interaction next to a regulated stream were studied using analytical and numerical models, based on field observations. Seasonality plays an important role in these interactions, but human activity may also alter its intensity.
Analysis of Borderline Substitution/Electron Transfer Pathways from Direct ab initio MD Simulations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamataka, H; Aida, M A.; Dupuis, Michel
Ab initio molecular dynamics simulations were carried out for the borderline reaction pathways in the reaction of CH2O?- with CH3Cl. The simulations reveal distinctive features of three types of mechanisms passing through the SN2-like transition state (TS): (i) a direct formation of SN2 products, (ii) a direct formation of ET products, and (iii) a 2-step formation of ET products via the SN2 valley. The direct formation of the ET product through the SN2-like TS appears to be more favorable at higher temperatures. The 2-step process depends on the amount of energy that goes into the C-C stretching mode.
NASA Technical Reports Server (NTRS)
Walker, D.; Fischbach, D.; Tetreault, R.
1996-01-01
The objective of this project was to investigate the feasibility of constructing a heat pump suitable for use as a heat rejection device in applications such as a lunar base. In this situation, direct heat rejection through the use of radiators is not possible at a temperature suitable for lde support systems. Initial analysis of a heat pump of this type called for a temperature lift of approximately 378 deg. K, which is considerably higher than is commonly called for in HVAC and refrigeration applications where heat pumps are most often employed. Also because of the variation of the rejection temperature (from 100 to 381 deg. K), extreme flexibility in the configuration and operation of the heat pump is required. A three-stage compression cycle using a refrigerant such as CFC-11 or HCFC-123 was formulated with operation possible with one, two or three stages of compression. Also, to meet the redundancy requirements, compression was divided up over multiple compressors in each stage. A control scheme was devised that allowed these multiple compressors to be operated as required so that the heat pump could perform with variable heat loads and rejection conditions. A prototype heat pump was designed and constructed to investigate the key elements of the high-lift heat pump concept. Control software was written and implemented in the prototype to allow fully automatic operation. The heat pump was capable of operation over a wide range of rejection temperatures and cooling loads, while maintaining cooling water temperature well within the required specification of 40 deg. C +/- 1.7 deg. C. This performance was verified through testing.
Performance analysis on a large scale borehole ground source heat pump in Tianjin cultural centre
NASA Astrophysics Data System (ADS)
Yin, Baoquan; Wu, Xiaoting
2018-02-01
In this paper, the temperature distribution of the geothermal field for the vertical borehole ground-coupled heat pump was tested and analysed. Besides the borehole ground-coupled heat pump, the system composed of the ice storage, heat supply network and cooling tower. According to the operation data for nearly three years, the temperature constant zone is in the ground depth of 40m -120m with a temperature gradient of about 3.0°C/100m. The temperature of the soil dropped significantly in the heating season, increased significantly in the cooling season, and reinstated in the transitional season. With the energy balance design of the heating and cooling and the existence of the soil thermal inertia, the soil temperature stayed in a relative stable range and the ground source heat pump system was operated with a relative high efficiency. The geothermal source heat pump was shown to be applicable for large scale utilization.
Pumping capacity and reliability of cryogenic micro-pump for micro-satellite applications
NASA Astrophysics Data System (ADS)
Zhang, Xin; Zhao, Yi; Li, Biao; Ludlow, Daryl
2004-10-01
In micro-satellites, delicate instruments are compacted into a limited space. This raises concerns of active cooling and remote cooling. Silicon based micro-pump arrays are employed thanks to manufacturing simplicity, a small cryogen charge, etc, and keep the instruments within a narrow cryogenic temperature range. The pumping capacity and reliability of the micro-pump are critical in terms of heat balance calculation and lifetime evaluation. The pumping capacity is associated with the diaphragm deflection while the reliability is associated with stress and fatigue. Both of them heavily depend on the silicon diaphragm, one of the key components. This paper examines the pumping capacity and reliability of the micro-pump under cryogenic temperature for micro-satellite applications. In this work, differential pressure was used for the actuation of a single-crystal silicon diaphragm. Diaphragm deflection and stress distribution were achieved using interferometry and micro-Raman spectroscopy, respectively. As a result, smaller pumping capacity was derived under cryogenic temperature, compared to that under room temperature, indicating a stiffer material. From stress mapping, the edge centers were believed to be the most vulnerable to fracture, which was further validated by analyzing the fracture diaphragm. Moreover, a fatigue testing was conducted for 1.8 million cycles with no damage found, verifying silicon as a viable material for long time operation in a cryogenic environment.
Measuring gas temperature during spin-exchange optical pumping process
NASA Astrophysics Data System (ADS)
Normand, E.; Jiang, C. Y.; Brown, D. R.; Robertson, L.; Crow, L.; Tong, X.
2016-04-01
The gas temperature inside a Spin-Exchange Optical Pumping (SEOP) laser-pumping polarized 3He cell has long been a mystery. Different experimental methods were employed to measure this temperature but all were based on either modelling or indirect measurement. To date there has not been any direct experimental measurement of this quantity. Here we present the first direct measurement using neutron transmission to accurately determine the number density of 3He, the temperature is obtained using the ideal gas law. Our result showed a surprisingly high gas temperature of 380°C, compared to the 245°C of the 3He cell wall temperature and 178°C of the optical pumping oven temperature. This experiment result may be used to further investigate the unsolved puzzle of the "X-factor" in the SEOP process which places an upper bound to the 3He polarization that can be achieved. Additional spin relaxation mechanisms might exist due to the high gas temperature, which could explain the origin of the X-factor.
Dual-Pump Coherent Anti-Stokes Raman Scattering Temperature and CO2 Concentration Measurements
NASA Technical Reports Server (NTRS)
Lucht, Robert P.; Velur-Natarajan, Viswanathan; Carter, Campbell D.; Grinstead, Keith D., Jr.; Gord, James R.; Danehy, Paul M.; Fiechtner, G. J.; Farrow, Roger L.
2003-01-01
Measurements of temperature and CO2 concentration using dual-pump coherent anti-Stokes Raman scattering, (CARS) are described. The measurements were performed in laboratory flames,in a room-temperature gas cell, and on an engine test stand at the U.S. Air Force Research Laboratory, Wright-Patterson Air Force Base. A modeless dye laser, a single-mode Nd:YAG laser, and an unintensified back-illuminated charge-coupled device digital camera were used for these measurements. The CARS measurements were performed on a single-laser-shot basis. The standard deviations of the temperatures and CO2 mole fractions determined from single-shot dual-pump CARS spectra in steady laminar propane/air flames were approximately 2 and 10% of the mean values of approximately 2000 K and 0.10, respectively. The precision and accuracy of single-shot temperature measurements obtained from the nitrogen part of the dual-pump CARS system were investigated in detail in near-adiabatic hydrogen/air/CO2 flames. The precision of the CARS temperature measurements was found to be comparable to the best results reported in the literature for conventional two-laser, single-pump CARS. The application of dual-pump CARS for single-shot measurements in a swirl-stabilized combustor fueled with JP-8 was also demonstrated.
Microgravity heat pump for space station thermal management.
Domitrovic, R E; Chen, F C; Mei, V C; Spezia, A L
2003-01-01
A highly efficient recuperative vapor compression heat pump was developed and tested for its ability to operate independent of orientation with respect to gravity while maximizing temperature lift. The objective of such a heat pump is to increase the temperature of, and thus reduce the size of, the radiative heat rejection panels on spacecrafts such as the International Space Station. Heat pump operation under microgravity was approximated by gravitational-independent experiments. Test evaluations include functionality, efficiency, and temperature lift. Commercially available components were used to minimize costs of new hardware development. Testing was completed on two heat pump design iterations--LBU-I and LBU--II, for a variety of operating conditions under the variation of several system parameters, including: orientation, evaporator water inlet temperature (EWIT), condenser water inlet temperature (CWIT), and compressor speed. The LBU-I system employed an ac motor, belt-driven scroll compressor, and tube-in-tube heat exchangers. The LBU-II system used a direct-drive AC motor compressor assembly and plate heat exchangers. The LBU-II system in general outperformed the LBU-I system on all accounts. Results are presented for all systems, showing particular attention to those states that perform with a COP of 4.5 +/- 10% and can maintain a temperature lift of 55 degrees F (30.6 degrees C) +/- 10%. A calculation of potential radiator area reduction shows that points with maximum temperature lift give the greatest potential for reduction, and that area reduction is a function of heat pump efficiency and a stronger function of temperature lift.
Temperature distribution of laser crystal in end-pumped DPSSL
NASA Astrophysics Data System (ADS)
Zheng, Yibo; Jia, Liping; Zhang, Lei; Wen, Jihua; Kang, Junjian
2009-11-01
The temperature distribution in different cooling system was studied. A thermal distribution model of laser crystal was established. Based on the calculation, the temperature distribution and deformation of ND:YVO4 crystal in different cooling system were obtained. When the pumping power is 2 W and the radius of pumping beams is 320μm, the temperature distribution and end face distortion of the laser crystal are lowest by using side directly hydrocooling method. The study shows that, the side directly hydrocooling method is a more efficient method to control the crystal temperature distribution and reduce the thermal effect.
Analyses of absorption distribution of a rubidium cell side-pumped by a Laser-Diode-Array (LDA)
NASA Astrophysics Data System (ADS)
Yu, Hang; Han, Juhong; Rong, Kepeng; Wang, Shunyan; Cai, He; An, Guofei; Zhang, Wei; Yu, Qiang; Wu, Peng; Wang, Hongyuan; Wang, You
2018-01-01
A diode-pumped alkali laser (DPAL) has been regarded as one of the most potential candidates to achieve high power performances of next generation. In this paper, we investigate the physical properties of a rubidium cell side-pumped by a Laser-Diode-Array (LDA) in this study. As the saturated concentration of a gain medium inside a vapor cell is extremely sensitive to the temperature, the populations of every energy-level of the atomic alkali are strongly relying on the vapor temperature. Thus, the absorption characteristics of a DPAL are mainly dominated by the temperature distribution. In this paper, the temperature, absorption, and lasing distributions in the cross-section of a rubidium cell side-pumped by a LDA are obtained by means of a complicated mathematic procedure. Based on the original end-pumped mode we constructed before, a novel one-direction side-pumped theoretical mode has been established to explore the distribution properties in the transverse section of a rubidium vapor cell by combining the procedures of heat transfer and laser kinetics together. It has been thought the results might be helpful for design of a side-pumped configuration in a high-powered DPAL.
The influence of heat sink temperature on the seasonal efficiency of shallow geothermal heat pumps
NASA Astrophysics Data System (ADS)
Pełka, Grzegorz; Luboń, Wojciech; Sowiżdżał, Anna; Malik, Daniel
2017-11-01
Geothermal heat pumps, also known as ground source heat pumps (GSHP), are the most efficient heating and cooling technology utilized nowadays. In the AGH-UST Educational and Research Laboratory of Renewable Energy Sources and Energy Saving in Miękinia, shallow geothermal heat is utilized for heating. In the article, the seasonal efficiency of two geothermal heat pump systems are described during the 2014/2015 heating season, defined as the period between 1st October 2014 and 30th April 2015. The first system has 10.9 kW heating capacity (according to European Standard EN 14511 B0W35) and extracts heat from three vertical geothermal loops at a depth of 80m each. During the heating season, tests warmed up the buffer to 40°C. The second system has a 17.03 kW heating capacity and extracts heat from three vertical geothermal loops at a depth of 100 m each, and the temperature of the buffer was 50°C. During the entire heating season, the water temperatures of the buffers was constant. Seasonal performance factors were calculated, defined as the quotient of heat delivered by a heat pump to the system and the sum of electricity consumed by the compressor, source pump, sink pump and controller of heat pumps. The measurements and calculations give the following results: - The first system was supplied with 13 857 kWh/a of heat and consumed 3 388 kWh/a electricity. The SPF was 4.09 and the average temperature of outlet water from heat pump was 40.8°C, and the average temperature of brine flows into the evaporator was 3.7 °C; - The second system was supplied with 12 545 kWh/a of heat and consumed 3 874 kWh/a electricity. The SPF was 3.24 and the average temperature of outlet water from heat pump was 51.6°C, and the average temperature of brine flows into the evaporator was 5.3°C. To summarize, the data shown above presents the real SPF of the two systems. It will be significant in helping to predict the SPF of objects which will be equipped with ground source heat pumps.
NASA Astrophysics Data System (ADS)
Huang, Wei; Tan, Rongqing; Li, Zhiyong; Han, Gaoce; Li, Hui
2017-03-01
A theoretical model based on common pump structure is proposed to analyze the output characteristics of a diode-pumped alkali vapor laser (DPAL) and XPAL (exciplex-pumped alkali laser). Cs-DPAL and Cs-Ar XPAL systems are used as examples. The model predicts that an optical-to-optical efficiency approaching 80% can be achieved for continuous-wave four- and five-level XPAL systems with broadband pumping, which is several times the pumped linewidth for DPAL. Operation parameters including pumped intensity, temperature, cell's length, mixed gas concentration, pumped linewidth, and output coupler are analyzed for DPAL and XPAL systems based on the kinetic model. In addition, the predictions of selection principal of temperature and cell's length are also presented. The concept of the equivalent "alkali areal density" is proposed. The result shows that the output characteristics with the same alkali areal density but different temperatures turn out to be equal for either the DPAL or the XPAL system. It is the areal density that reflects the potential of DPAL or XPAL systems directly. A more detailed analysis of similar influences of cavity parameters with the same areal density is also presented.
Downwell pump reliability: Geothermal experience update: Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellis, P.F.
1988-01-01
Geothermal resources with temperatures between 250/sup 0/ and 360/sup 0/F (121/sup 0/C and 182/sup 0/C) are prime candidates for binary-cycle power generation, and constitute about 80% of the power-capable resources in the United States. The successful exploitation of these resources requires reliable high-capacity downwell brine production pumps, but earlier experience showed that high-capacity, high-temperature geothermal production pumps had many problems which resulted in a mean time-to-failure (MTTF) of less than 1000 h. However, steady progress has been made since 1981, and a large body of experience has been acquired by three geothermal binary plants. This survey of high-temperature geothermal downwellmore » pump users and manufacturers updates a prior survey (AP-3572) completed in early 1983. This survey traces the development of lineshaft pump technology from the late 1970s to the present (mid-1987), detailing the advances in design, materials selection, and operating practices. Case histories of 72 lineshaft pumps installed at three geothermal binary plants since late 1981 are documented, including some detailed cause of failure reports. In the recent past, pump lives in excess of 7000 h have become common, but a high continuing rate of premature failures resulted in a mean time-to-failure (MTTF) of about 5000 h. Based on recent advances which appear likely to eliminate most premature failures, the estimated near-term MTTF will be on the order of 8000 h. The survey found almost no development of high-temperature geothermal electric submersible pumps (ESP's) or close-coupled downwell hydraulic turbopumps, and concluded that considerable development and demonstration will be needed before these technologies are able to compete with existing high-temperature geothermal lineshaft pump technology. 36 refs., 10 figs., 25 tabs.« less
Frances, A; Clarkin, J F; Gilmore, M; Hurt, S W; Brown, R
1984-09-01
The authors compared the reliability of two methods of distinguishing borderline personality disorder--DSM-III and the Diagnostic Interview for Borderline Patients. The reference group, outpatients with other personality disorders and without major axis I pathology, was more difficult to distinguish from the patients with borderline personality disorder than such groups used in previous samples. The sensitivity and specificity of the Diagnostic Interview for Borderline Patients were calculated, with DSM-III used as a criterion. The findings confirm considerable overlap between borderline and schizotypal personality disorders, more impairment in functioning in borderline patients than in those with other personality disorders, and the high reliability with which borderline personality disorder can be diagnosed.
Analysis of borderline substitution/electron transfer pathways from direct ab initio MD simulations
NASA Astrophysics Data System (ADS)
Yamataka, Hiroshi; Aida, Misako; Dupuis, Michel
2002-02-01
Ab initio molecular dynamics simulations were carried out for the borderline reaction pathways in the reaction of CH 2O rad - with CH 3Cl. The simulations reveal distinctive features of three types of mechanisms passing through the S N2-like transition state (TS): (i) a direct formation of S N2 products, (ii) a direct formation of ET products, and (iii) a two-step formation of ET products via the S N2 valley. The direct formation of the ET product through the S N2-like TS appears to be more favorable at higher temperatures. The two-step process depends on the amount of energy that goes into the C-C stretching mode.
End-pumped 1.5 microm monoblock laser for broad temperature operation.
Schilling, Bradley W; Chinn, Stephen R; Hays, A D; Goldberg, Lew; Trussell, C Ward
2006-09-01
We describe a next-generation monoblock laser capable of a greater than 10 mJ, 1.5 microm output at 10 pulses/s (pps) over broad ambient temperature extremes with no active temperature control. The transmitter design is based on a Nd:YAG laser with a Cr4+ passive Q switch and intracavity potassium titanyl phosphate optical parametric oscillator. To achieve the repetition rate and efficiency goals of this effort, but still have wide temperature capability, the Nd:YAG slab is end pumped with a 12-bar stack of 100 W (each) diode bars. Different techniques for focusing the pump radiation into the 4.25 mmx4.25 mm end of the slab are compared, including a lensed design, a reflective concentrator, and a lens duct. A wide temperature operation (-20 degrees C to 50 degrees C) for each end-pumped configuration is demonstrated.
An Efficient End-Pumped Ho:Tm:YLF Disk Amplifier
NASA Technical Reports Server (NTRS)
Yu, Ji-Rong; Petros, Mulugeta; Singh, Upendra N.; Barnes, Norman P.
2000-01-01
An efficient diode-pumped, room temperature Ho:Tm:YLF disk amplifier was realized by end-pump configuration. Compared to side pump configuration, about a factor three improvement in system efficiency has been demonstrated.
Pumping liquid metal at high temperatures up to 1,673 kelvin
NASA Astrophysics Data System (ADS)
Amy, C.; Budenstein, D.; Bagepalli, M.; England, D.; Deangelis, F.; Wilk, G.; Jarrett, C.; Kelsall, C.; Hirschey, J.; Wen, H.; Chavan, A.; Gilleland, B.; Yuan, C.; Chueh, W. C.; Sandhage, K. H.; Kawajiri, Y.; Henry, A.
2017-10-01
Heat is fundamental to power generation and many industrial processes, and is most useful at high temperatures because it can be converted more efficiently to other types of energy. However, efficient transportation, storage and conversion of heat at extreme temperatures (more than about 1,300 kelvin) is impractical for many applications. Liquid metals can be very effective media for transferring heat at high temperatures, but liquid-metal pumping has been limited by the corrosion of metal infrastructures. Here we demonstrate a ceramic, mechanical pump that can be used to continuously circulate liquid tin at temperatures of around 1,473-1,673 kelvin. Our approach to liquid-metal pumping is enabled by the use of ceramics for the mechanical and sealing components, but owing to the brittle nature of ceramics their use requires careful engineering. Our set-up enables effective heat transfer using a liquid at previously unattainable temperatures, and could be used for thermal storage and transport, electric power production, and chemical or materials processing.
Optimising the efficiency of pulsed diode pumped Yb:YAG laser amplifiers for ns pulse generation.
Ertel, K; Banerjee, S; Mason, P D; Phillips, P J; Siebold, M; Hernandez-Gomez, C; Collier, J C
2011-12-19
We present a numerical model of a pulsed, diode-pumped Yb:YAG laser amplifier for the generation of high energy ns-pulses. This model is used to explore how optical-to-optical efficiency depends on factors such as pump duration, pump spectrum, pump intensity, doping concentration, and operating temperature. We put special emphasis on finding ways to achieve high efficiency within the practical limitations imposed by real-world laser systems, such as limited pump brightness and limited damage fluence. We show that a particularly advantageous way of improving efficiency within those constraints is operation at cryogenic temperature. Based on the numerical findings we present a concept for a scalable amplifier based on an end-pumped, cryogenic, gas-cooled multi-slab architecture.
Experimental investigation on charcoal adsorption for cryogenic pump application
NASA Astrophysics Data System (ADS)
Scannapiego, Matthieu; Day, Christian
2017-12-01
Fusion reactors are generating energy by nuclear fusion between deuterium and tritium. In order to evacuate the high gas throughputs from the plasma exhaust, large pumping speed systems are required. Within the European Fusion Programme, the Karlsruhe Institute of Technology (KIT) has taken the lead to design a three-stage cryogenic pump that can provide a separation function of hydrogen isotopes from the remaining gases; hence limiting the tritium inventory in the machine. A primary input parameter for the detailed design of a cryopump is the sticking coefficient between the gas and the pumping surface. For this purpose, the so-called TIMO open panel pump experiment was conducted in the TIMO-2 test facility at KIT in order to measure pumping speeds on an activated carbon surface cooled at temperatures between 6 K and 22 K, for various pure gases and gas mixtures, under fusion relevant gas flow conditions, and for two different geometrical pump configurations. The influences of the panel temperature, the gas throughput and the intake gas temperature on the pumping speed have been characterized, providing valuable qualitative results for the design of the three-stage cryopump. In a future work, supporting Monte Carlo simulations should allow for derivation of the sticking coefficients.
Histopathology of fish. V. Gill disease
1957-01-01
Possibly no single disease accounts for greater annual mortality than gill disease. Apparently endemic in many hatcheries, the disease is characterized by periodic sharp upsurges which are sometimes correlated with rising water temperatures, excessive foreign matter in the water (Wales and Evins 1937), or borderline nutritional conditions.
BELSKY, DANIEL W.; CASPI, AVSHALOM; ARSENEAULT, LOUISE; BLEIDORN, WIEBKE; FONAGY, PETER; GOODMAN, MARIANNE; HOUTS, RENATE; MOFFITT, TERRIE E.
2012-01-01
It has been reported that borderline personality related characteristics can be observed in children, and that these characteristics are associated with increased risk for the development of borderline personality disorder. It is not clear whether borderline personality related characteristics in children share etiological features with adult borderline personality disorder. We investigated the etiology of borderline personality related characteristics in a longitudinal cohort study of 1,116 pairs of same-sex twins followed from birth through age 12 years. Borderline personality related characteristics measured at age 12 years were highly heritable, were more common in children who had exhibited poor cognitive function, impulsivity, and more behavioral and emotional problems at age 5 years, and co-occurred with symptoms of conduct disorder, depression, anxiety, and psychosis. Exposure to harsh treatment in the family environment through age 10 years predicted borderline personality related characteristics at age 12 years. This association showed evidence of environmental mediation and was stronger among children with a family history of psychiatric illness, consistent with diathesis–stress models of borderline etiology. Results indicate that borderline personality related characteristics in children share etiological features with borderline personality disorder in adults and suggest that inherited and environmental risk factors make independent and interactive contributions to borderline etiology. PMID:22293008
Belsky, Daniel W; Caspi, Avshalom; Arseneault, Louise; Bleidorn, Wiebke; Fonagy, Peter; Goodman, Marianne; Houts, Renate; Moffitt, Terrie E
2012-02-01
It has been reported that borderline personality related characteristics can be observed in children, and that these characteristics are associated with increased risk for the development of borderline personality disorder. It is not clear whether borderline personality related characteristics in children share etiological features with adult borderline personality disorder. We investigated the etiology of borderline personality related characteristics in a longitudinal cohort study of 1,116 pairs of same-sex twins followed from birth through age 12 years. Borderline personality related characteristics measured at age 12 years were highly heritable, were more common in children who had exhibited poor cognitive function, impulsivity, and more behavioral and emotional problems at age 5 years, and co-occurred with symptoms of conduct disorder, depression, anxiety, and psychosis. Exposure to harsh treatment in the family environment through age 10 years predicted borderline personality related characteristics at age 12 years. This association showed evidence of environmental mediation and was stronger among children with a family history of psychiatric illness, consistent with diathesis-stress models of borderline etiology. Results indicate that borderline personality related characteristics in children share etiological features with borderline personality disorder in adults and suggest that inherited and environmental risk factors make independent and interactive contributions to borderline etiology.
Conway, Christopher C; Hipwell, Alison E; Stepp, Stephanie D
2017-07-01
Borderline personality disorder (PD) historically is construed as an unremitting condition with poor prognosis. The present study takes a new approach to examining stability and change in borderline PD by explaining symptom expression in terms of an unchanging foundation-termed borderline proneness-on one hand, and transitory influences on the other. We monitored borderline PD symptoms annually in a large sample of high-risk adolescent girls ( N = 2,450) from ages 14 to 20. Trait-state-occasion modeling revealed that just over half (52-57%) of borderline PD symptom variation was attributable to fixed borderline proneness, whereas the remainder was subject to change across yearly measurement occasions. This degree of stability was no larger than the corresponding estimate for depression, a condition known for its variable course. Our results indicate that, contrary to its reputation, borderline pathology is not set in stone, and it fluctuates in response to situational influences.
Chabrol, H; Chouicha, K; Montovany, A; Callahan, S
2001-01-01
1,363 high school students were solicited to complete a personality disorder questionnaire and were encouraged to continue in the study by signing up for interviews with Master's level psychology students. 107 students (7.8%, 34 males, 73 females, mean age = 16.7 +/- 1.8) manifested themselves for the interview and were assessed by using structured diagnostic interviews for borderline personality disorder and major depressive disorder (DIB-R, Revised Diagnostic Interview for Borderlines; MINI, Mini International Neuropsychiatric Interview). The interviews were audiotaped. Interrater reliability was determined by independent ratings of 12 borderline subjects and 12 non-borderline subjects (kappa: 0.795). The distribution of the 107 subjects based on the number of DSM IV borderline personality disorder criteria indicated a gradual dispersion suggesting a continuum from normality to borderline personality disorder: 8% of the subjects met none of the criteria; 16% met one criterion; 17% met two; 12.5%, three; 13.7%, four; 8.4%, five; 5.6%, six; 9.3%, seven; 4.6%, eight; 4.6%, nine. Thirty-five of these 107 subjects (32.7%, 6 males, 29 females, mean age = 16.7 +/- 1.7) received a diagnosis of borderline personality disorder according to DSM IV criteria. The most frequent symptoms were paranoid ideation or dissociative symptoms (97.1%), affective instability (88.6%), inappropriate, intense anger (85.6%), suicidal gestures or automutilation (82.9%), followed by frantic efforts to avoid abandonment (77%), impulsivity (65.7%), unstable and intense relationships (62.9%), identity disturbance (60%), and emptiness (57.1%). The comparison between borderline and non-borderline subjects showed that all borderline personality disorder criteria discriminated significantly between the two groups. The high incidence of paranoid ideation (97.1%) and dissociative experiences (65.7%) in the borderline group suggests the pertinence of criterion 9 in the diagnosis of borderline personality disorder in adolescents. Two criteria of schizotypal personality disorder were also frequent in this group: 68.6% of the borderline group reported odd beliefs or magical thinking, in particular beliefs in clairvoyance or telepathy and 88.6% reported unusual perceptual experiences, in particular sensing the presence of a force or person and bodily illusions. Moreover, 31.4% of the borderline group reported transient "quasi" psychotic experiences, mainly "quasi" visual hallucinations. Auditory hallucinations or delusional ideas were not observed. This symptomatology suggests a "quasi" psychotic dimension of adolescent borderline personality disorder. Affective instability was the next most frequent symptom which was usually marked by a cyclothymic appearance. Comorbidity with major depressive disorder was high: 85.7% of the borderline subjects had a concurrent diagnosis of major depression versus 45.8% of the non-borderline subjects. Thus, major depression is more frequent than most of the borderline personality disorder criteria, with the exception of the already noted paranoid ideation and affective instability. Hypomanic symptoms were frequent in the borderline group (65.7%) as well as in the non-borderline group (38.8%). This symptomatology suggests that adolescent borderline personality disorder is linked to an attenuated bipolar spectrum characterised by major depressive episodes and soft signs of bipolarity. However, hypomanic symptoms, which were quite frequent in non-borderline subjects, might also be due to a mechanism of defence, i.e. the denial of depression. Comorbidity with anxiety disorders appeared also to be high: anxiety symptoms were found in 91.4% of the borderline subjects who reported symptoms of generalised anxiety disorder, panic disorder, and somatoform disorders. The overall clinical appearance of these borderline adolescents not referred for treatment seemed to be quite similar to that of borderline adolescents in clinical samples. This study shows that adolescent borderline personality disorder in non-clinical population is a serious disorder characterised by the importance of mental suffering and behavioural disturbances the disorganising power of which may fix the developmental process in a pathological pathway. Adolescent borderline personality disorder appears in this study to be strongly associated with major depressive disorder and at-risk behaviours linked to impulsivity, affective instability, and suicidal ideation. However, this study found an absence of precise cut-off between borderline and non-borderline subjects. Two factors might have contributed to the appearance of a continuum. First, some degree of impulsivity and instability in affectivity, self-images and interpersonal relationships is part of normal adolescence. (ABSTRACT TRUNCATED)
Fluctuations in oxygen influence facultative endothermy in bumblebees.
Dzialowski, Edward M; Tattersall, Glenn J; Nicol, Stewart C; Frappell, Peter B
2014-11-01
Bumblebees are facultative endotherms, having the ability to elevate thorax temperature above ambient temperature by elevating metabolism. Here, we investigated the influence of hypoxia on metabolic demands and thermoregulatory capabilities of the bumblebee Bombus terrestris. We measured thorax temperature, rates of oxygen consumption and carbon dioxide production, and abdominal pumping rates of bees randomly exposed to oxygen levels of 20, 15, 10 and 5 kPa at 26°C. Under normoxia, bumblebees maintained an elevated mean thorax temperature of 35.5°C. There was no significant change in thorax temperature at 15 kPa O2 (33.4°C). Mean thorax temperature decreased significantly at 10 kPa O2 (31.6°C) and 5 kPa O2 (27.3°C). Bees were able to maintain an elevated metabolic rate at 15 and 10 kPa O2. In normoxia, endothermic bees exhibited periods of rapid abdominal pumping (327 min(-1)) interspaced by periods of no abdominal pumping. At 10 kPa O2, abdominal pumping rate decreased (255 min(-1)) but became more continuous. Upon exposure to 5 kPa, metabolic rate and abdominal pumping rate (152 min(-1)) decreased, although the animals continued abdominal pumping at the reduced rate throughout the exposure period. Bumblebees are able to meet the energetic demands of endothermy at 15 kPa O2, but become compromised at levels of 10 kPa O2 and below. © 2014. Published by The Company of Biologists Ltd.
1300 nm optically pumped quantum dot spin vertical external-cavity surface-emitting laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Alharthi, S. S., E-mail: ssmalh@essex.ac.uk; Henning, I. D.; Adams, M. J.
We report a room temperature optically pumped Quantum Dot-based Spin-Vertical-External-Cavity Surface-Emitting laser (QD Spin-VECSEL) operating at the telecom wavelength of 1.3 μm. The active medium was composed of 5 × 3 QD layers; each threefold group was positioned at an antinode of the standing wave of the optical field. Circularly polarized lasing in the QD-VECSEL under Continuous-Wave optical pumping has been realized with a threshold pump power of 11 mW. We further demonstrate at room temperature control of the QD-VECSEL output polarization ellipticity via the pump polarization.
A capital cost comparison of commercial ground-source heat pump systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rafferty, K.
1994-06-01
The purpose of the report is to compare capital costs associated with the three designs of ground source heat pumps. Specifically, the costs considered are those associated with the heat source/heat sink or ground source portion of the system. In order to standardize the heat rejection over the three designs, it was assumed that the heat pump loop would operate at a temperature range of 85{degree} (to the heat pumps) to 95{degree} (from the heat pumps) under peak conditions. The assumption of constant loop temperature conditions for all three permits an apples-to-apples comparison of the alternatives.
NASA Astrophysics Data System (ADS)
Shen, Binglin; Xu, Xingqi; Xia, Chunsheng; Pan, Bailiang
2017-11-01
Combining the kinetic and fluid dynamic processes in static and flowing-gas diode-pumped alkali vapor lasers, a comprehensive physical model with three cyclically iterative algorithms for simulating the three-dimensional pump and laser intensities as well as temperature distribution in the vapor cell of side-pumped alkali vapor lasers is established. Comparison with measurement of a static side-pumped cesium vapor laser with a diffuse type hollow cylinder cavity, and with classical and modified models is made. Influences of flowed velocity and pump power on laser power are calculated and analyzed. The results have demonstrated that for high-power side-pumped alkali vapor lasers, it is necessary to take into account the three-dimensional distributions of pump energy, laser energy and temperature in the cell to simultaneously obtain the thermal features and output characteristics. Therefore, the model can deepen the understanding of the complete kinetic and fluid dynamic mechanisms of a side-pumped alkali vapor laser, and help with its further experimental design.
Measured Performance of a Low Temperature Air Source Heat Pump
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, R. K.
2013-09-01
A 4-ton Low Temperature Heat Pump (LTHP) manufactured by Hallowell International was installed in a residence near New Haven, Connecticut and monitored over two winters of operation. After attending to some significant service issues, the heat pump operated as designed. This report should be considered a review of the dual compressor 'boosted heat pump' technology. The Low Temperature Heat Pumpsystem operates with four increasing levels of capacity (heat output) as the outdoor temperature drops. The system was shown to select capacity correctly, supplying the appropriate amount of heat to the house across the full range of outdoor temperatures. The system'smore » Coefficient of Performance (Seasonal COP, or SCOP) over two entire winters was calculated, based on measured data, to be 3.29over the first winter and 2.68 over the second winter. A second seasonal efficiency calculation by a different method yielded a SCOP of 2.78 for the first winter and 2.83 for the second winter. This second seasonal efficiency calculation was determined by comparing measured heat pump energy use to the in situ energy use with resistance heat alone. This method is the ratio of the slopes of thedaily energy use load lines.« less
Zimmerman, Mark; Martinez, Jennifer H; Young, Diane; Chelminski, Iwona; Dalrymple, Kristy
2012-12-01
The morbidity associated with bipolar disorder is, in part, responsible for repeated calls for improved detection and recognition. No such clinical commentary exists for improved detection of borderline personality disorder in depressed patients. Clinical experience suggests that borderline personality disorder is as disabling as bipolar disorder; however, no studies have directly compared the two disorders. For this reason we undertook the current analysis from the Rhode Island Methods to Improve Diagnostic Assessment and Services (MIDAS) project comparing unemployment and disability rates in patients with bipolar disorder and borderline personality disorder. Patients were interviewed with semi-structured interviews. We compared three non-overlapping groups of depressed patients: (i) 181 patients with DSM-IV major depressive disorder and borderline personality disorder, (ii) 1068 patients with major depressive disorder without borderline personality disorder, and (iii) 84 patients with bipolar depression without borderline personality disorder. Compared to depressed patients without borderline personality disorder, depressed patients with borderline personality disorder were significantly more likely to have been persistently unemployed. A similar difference was found between patients with bipolar depression and major depressive disorder without borderline personality disorder. No differences were found between patients with bipolar depression and depression with borderline personality disorder. Both bipolar disorder and borderline personality disorder were associated with impaired occupational functioning and thus carry a significant public health burden. Efforts to improve detection of borderline personality disorder in depressed patients might be as important as the recognition of bipolar disorder. © 2012 John Wiley and Sons A/S.
Hydride heat pump with heat regenerator
NASA Technical Reports Server (NTRS)
Jones, Jack A. (Inventor)
1991-01-01
A regenerative hydride heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system. A series of at least four canisters containing a lower temperature performing hydride and a series of at least four canisters containing a higher temperature performing hydride is provided. Each canister contains a heat conductive passageway through which a heat transfer fluid is circulated so that sensible heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.
1981-06-01
shutdown. Before start up the hot oil would be pumped ( auxillary pump) back through the engine on the high pressure side of the engine’ s oil pump. This...insulation heating was applied. Temperature plots Figure 14* to Figure 16* show the battery cooling curves for auxillary heating when 37mm of medium
NASA Technical Reports Server (NTRS)
Schunk, R. Gregory; Hunt, Patrick L. (Technical Monitor)
2001-01-01
Preliminary results from a thermal/flow analysis of the Purge Control Pump Assembly (PCPA) indicate that pump performance (mass flow rate) is enhanced via cooling of the housing and lowering of the inlet vapor quality. Under a nominal operational profile (25% duty cycle or less), at the maximum motor dissipation, it appears that the peristaltic tubing temperature will still remain significantly below the expected UPA condenser temperature (78 F max versus approximately 105 F in the condenser) permitting condensation in the pump head.
Simulations of thermal lensing of a Ti:Sapphire crystal end-pumped with high average power
NASA Astrophysics Data System (ADS)
Wagner, Gerd; Shiler, Max; Wulfmeyer, Volker
2005-10-01
A detailed 3-dimensional calculation of the temperature field of a laser crystal pumped with high average power is presented. The pump configuration, the anisotropy of a Brewster-angle-cut Ti:Sapphire crystal, and the temperature dependence of the thermal conductivity are taken into account. The corresponding focal length of the thermal lens is calculated for pump levels up to 100 W. This refined thermal model is the basis for a optimized resonator design of a high-average power differential absorption lidar system transmitter.
Simulations of thermal lensing of a Ti:Sapphire crystal end-pumped with high average power.
Wagner, Gerd; Shiler, Max; Wulfmeyer, Volker
2005-10-03
A detailed 3-dimensional calculation of the temperature field of a laser crystal pumped with high average power is presented. The pump configuration, the anisotropy of a Brewster-angle-cut Ti:Sapphire crystal, and the temperature dependence of the thermal conductivity are taken into account. The corresponding focal length of the thermal lens is calculated for pump levels up to 100 W. This refined thermal model is the basis for a optimized resonator design of a high-average power differential absorption lidar system transmitter.
Ibrahim, Jeyda; Cosgrave, Nicola; Woolgar, Matthew
2018-01-01
Borderline personality disorder has repeatedly been associated with a history of maltreatment in childhood; however, research on maltreatment and its link to borderline features in children is limited. The aim of this review is to synthesise the existing data on the association between maltreatment and borderline features in childhood. In total, 10 studies were included in this systematic review. Studies indicated that children with borderline features were more likely to have a history of maltreatment, and that children who had been maltreated were more likely to present with borderline features. Other risk factors such as cognitive and executive functioning deficits, parental dysfunction and genetic vulnerability were also identified across studies. This review adds to the literature by highlighting maltreatment as a risk factor for borderline features in childhood. Longitudinal research is required to establish the link between childhood borderline features and adult borderline features. Implications for early identification, prevention and intervention services are discussed.
Design of a high-pressure circulating pump for viscous liquids.
Seifried, Bernhard; Temelli, Feral
2009-07-01
The design of a reciprocating dual action piston pump capable of circulating viscous fluids at pressures of up to 34 MPa (5000 psi) and temperatures up to 80 degrees C is described. The piston of this pump is driven by a pair of solenoids energized alternatively by a 12 V direct current power supply controlled by an electronic controller facilitating continuously adjustable flow rates. The body of this seal-less pump is constructed using off-the-shelf parts eliminating the need for custom made parts. Both the electronic controller and the pump can be assembled relatively easily. Pump performance has been evaluated at room temperature (22 degrees C) and atmospheric pressure using liquids with low and moderately high viscosities, such as ethanol and corn oil, respectively. At ambient conditions, the pump delivered continuous flow of ethanol and corn oil at a flow rate of up to 170 and 17 cm3/min, respectively. For pumping viscous fluids comparable to corn oil, an optimum reciprocation frequency was ascertained to maximize flow rate. For low viscosity liquids such as ethanol, a linear relationship between the flow rate and reciprocation frequency was determined up to the maximum reciprocation frequency of the pump. Since its fabrication, the pump has been used in our laboratory for circulating triglycerides in contact with supercritical carbon dioxide at pressures of up to 25 MPa (3600 psi) and temperatures up to 70 degrees C on a daily basis for a total of more than 1500 h of operation functioning trouble free.
Aspects of depression associated with borderline personality disorder.
Rogers, J H; Widiger, T A; Krupp, A
1995-02-01
Shared symptoms between borderline personality disorder and depression have resulted in inherent difficulties in evaluating the relationship between these disorders. Some theorists have argued that depression in patients with borderline personality disorder is qualitatively distinct from depression in nonborderline patients. The purpose of this study was to empirically identify aspects of depression most associated with borderline personality disorder. Through interview and self-report measures, the authors studied depression in 50 inpatients, 21 of whom had borderline personality disorder. The aspects of depression most associated with borderline personality disorder were self-condemnation, emptiness, abandonment fears, self-destructiveness, and hopelessness; boredom and somatic complaints exhibited no association. Depression associated with borderline pathology appears to be in some respects unique, as well as distinct from nonborderline depression. The study's implications delineate the importance of considering the phenomenological aspects of depression in borderline personality disorder.
Richman, Mara J; Unoka, Zsolt
2015-12-01
Patients with major depression and borderline personality disorder are characterised by a distorted perception of other people's intentions. Deficits in mental state decoding are thought to be the underlying cause of this clinical feature. To examine, using meta-analysis, whether mental state decoding abilities in patients with major depression and borderline personality disorder differ from those of healthy controls. A systematic review of 13 cross-sectional studies comparing Reading in the Mind of the Eyes Test (RMET) accuracy performance of patients with major depression or borderline personality disorder and healthy age-matched controls (n = 976). Valence scores, where reported, were also assessed. Large significant deficits were seen for global RMET performance in patients with major depression (d = -0.751). The positive RMET valence scores of patients with depression were significantly worse; patients with borderline personality disorder had worse neutral scores. Both groups were worse than controls. Moderator analysis revealed that individuals with comorbid borderline personality disorder and major depression did better than those with borderline personality disorder alone on accuracy. Those with comorbid borderline personality disorder and any cluster B or C personality disorder did worse than borderline personality disorder alone. Individuals with both borderline personality disorder and major depression performed better then those with borderline personality disorder without major depression for positive valence. These findings highlight the relevance of RMET performance in patients with borderline personality disorder and major depression, and the importance of considering comorbidity in future analysis. © The Royal College of Psychiatrists 2015.
The pain of being borderline: dysphoric states specific to borderline personality disorder.
Zanarini, M C; Frankenburg, F R; DeLuca, C J; Hennen, J; Khera, G S; Gunderson, J G
1998-01-01
The objective of this study was to identify the dysphoric states that best characterize patients meeting criteria for borderline personality disorder and distinguish them from those in patients with other forms of personality disorder. One hundred forty-six patients with criteria-defined borderline personality disorder and 34 Axis II controls filled out the Dysphoric Affect Scale, a 50-item self-report measure that was designed for this purpose and has good internal consistency and test-retest reliability. Twenty-five dysphoric states (mostly affects) were found to be significantly more common among borderline patients than controls but nonspecific to borderline personality disorder. Twenty-five other dysphoric states (mostly cognitions) were found to be both significantly more common among borderline patients than controls and highly specific to borderline personality disorder. These states tended to fall into one of four clusters: (1) extreme feelings, (2) destructiveness or self-destructiveness, (3) fragmentation or "identitylessness," and (4) victimization. In addition, three of the 25 more-specific states (feeling betrayed, like hurting myself, and completely out of control), when occurring together, were particularly strongly associated with the borderline diagnosis. Equally important, overall mean Dysphoric Affect Scale scores correctly distinguished borderline personality disorder from other personality disorders in 84% of the subjects. Taken together, the results of this study suggest that the subjective pain of borderline patients may be both more pervasive and more multifaceted than previously recognized, and that the overall "amplitude" of this pain may be a particularly good marker for the borderline diagnosis.
Heat Radiators for Electromagnetic Pumps
NASA Technical Reports Server (NTRS)
Campana, R. J.
1986-01-01
Report proposes use of carbon/carbon composite radiators in electromagnetic coolant pumps of nuclear reactors on spacecraft. Carbon/carbon composite materials function well at temperatures in excess of 2,200 K. Aluminum has melting temperature of only 880 K.
Maximum Oxygen Content of Flowing Eutectic NaK in a Stainless Steel System.
EUTECTICS, ALKALI METAL ALLOYS), (*LIQUID METALS, OXYGEN), (*POTASSIUM ALLOYS, SODIUM ALLOYS), LIQUID METAL PUMPS , FLUID FLOW, CONCENTRATION...CHEMISTRY), HIGH TEMPERATURE, FLOWMETERS, STAINLESS STEEL, ELECTROMAGNETIC PUMPS , TEMPERATURE, SAMPLING, LIQUID METAL COOLANTS, OXIDES, CRYSTALLIZATION.
Low-temperature thermal control for a lunar base
NASA Technical Reports Server (NTRS)
Swanson, Theodore D.; Radermacher, Reinhard; Costello, Frederick A.; Moore, James S., Jr.; Mengers, David R.
1990-01-01
The generic problem of rejecting low- to moderate-temperature heat from space facilities located in a hot thermal sink environment is studied, and the example of a lunar base located near the equator is described. The effective thermal sink temperature is often above or near nominal room temperature. A three heat pump assisted thermal bus concept appears to be the most viable as they are the least sensitive to environmental conditions. Weight estimates are also developed for each of the five thermal control concepts studied: (1) 149kg/kW for a central thermal loop with unitary heat pumps; (2) 133 kg/kW for a conventional bus connected to large, central heat pumps at the radiator; (3) 134 kg/kW for a central, dual loop heat pump concept; (4) 95 kg/kW for the selective field-of-view radiator; and (5) 126 kg/kW for the regolith concept.
Thermal control systems for low-temperature heat rejection on a lunar base
NASA Technical Reports Server (NTRS)
Sridhar, K. R.; Gottmann, Matthias; Nanjundan, Ashok
1993-01-01
One of the important issues in the design of a lunar base is the thermal control system (TCS) used to reject low-temperature heat from the base. The TCS ensures that the base and the components inside are maintained within an acceptable temperature range. The temperature of the lunar surface peaks at 400 K during the 336-hour lunar day. Under these circumstances, direct dissipation of waste heat from the lunar base using passive radiators would be impractical. Thermal control systems based on thermal storage, shaded radiators, and heat pumps have been proposed. Based on proven technology, innovation, realistic complexity, reliability, and near-term applicability, a heat pump-based TCS was selected as a candidate for early missions. In this report, Rankine-cycle heat pumps and absorption heat pumps (ammonia water and lithium bromide-water) have been analyzed and optimized for a lunar base cooling load of 100 kW.
[The heating effect of the Er3+/Yb3+ doped Y2O3 nanometer powder by 980 nm laser diode pumping].
Zheng, Long-Jiang; Gao, Xiao-Yang; Liu, Hai-Long; Li, Bing; Xu, Chen-Xi
2013-01-01
The Er3+ and Yb3+ doped Y2O3 Nano powder was prepared by sol-gel method. Based on 2H11/2 --> 4I15/2 and 4S3/2 --> 4I15/2 green conversion luminescence intensity rate of Er3+, the sample surface temperature changes caused by the increase in 980 nm diode laser pump power were studied. The results show that with pump power increasing, the sample surface temperature substantially rises. And the surface temperature reached to 820 K when the pump power was 1 000 mW. The phenomenon plays an important role in the analysis of upconversion process, especially with saturation power. And this feature has a potential application prospect in the biomedicine, soft tissue hole burning as well as the field of temperature sensing materials.
Magnetic heat pumping near room temperature
NASA Technical Reports Server (NTRS)
Brown, G. V.
1976-01-01
It is shown that magnetic heat pumping can be made practical at room temperature by using a ferromagnetic material with a Curie point at or near operating temperature and an appropriate regenerative thermodynamic cycle. Measurements are performed which show that gadolinium is a resonable working material and it is found that the application of a 7-T magnetic field to gadolinium at the Curie point (293 K) causes a heat release of 4 kJ/kg under isothermal conditions or a temperature rise of 14 K under adiabatic conditions. A regeneration technique can be used to lift the load of the lattice and electronic heat capacities off the magnetic system in order to span a reasonable temperature difference and to pump as much entropy per cycle as possible
Matter, energy, and heat transfer in a classical ballistic atom pump.
Byrd, Tommy A; Das, Kunal K; Mitchell, Kevin A; Aubin, Seth; Delos, John B
2014-11-01
A ballistic atom pump is a system containing two reservoirs of neutral atoms or molecules and a junction connecting them containing a localized time-varying potential. Atoms move through the pump as independent particles. Under certain conditions, these pumps can create net transport of atoms from one reservoir to the other. While such systems are sometimes called "quantum pumps," they are also models of classical chaotic transport, and their quantum behavior cannot be understood without study of the corresponding classical behavior. Here we examine classically such a pump's effect on energy and temperature in the reservoirs, in addition to net particle transport. We show that the changes in particle number, of energy in each reservoir, and of temperature in each reservoir vary in unexpected ways as the incident particle energy is varied.
Cottingham, James G.
1977-01-01
Method and apparatus for the use of hydrides to exhaust heat from one temperature source and deliver the thermal energy extracted for use at a higher temperature, thereby acting as a heat pump. For this purpose there are employed a pair of hydridable metal compounds having different characteristics working together in a closed pressure system employing a high temperature source to upgrade the heat supplied from a low temperature source.
NASA Technical Reports Server (NTRS)
Powell, A. H.; Amos, J. C.
1972-01-01
A three-phase helical induction electromagnetic pump designed for the boiler feed pump of a potassium Rankine cycle space power system was developed and built. It was mounted in a liquid metal test loop and successfully tested over a range of potassium temperatures from 900 to 1400 F, flow rates from 0.75 to 4.85 lb/sec, developed pressures up to 340 psi, net positive suction head from 1 to 22 psi, and NaK coolant temperatures from 800 to 950 F. Maximum efficiency at design point conditions of 3.25 lb/sec flow rate, 240 psi developed head, 1000 F potassium inlet temperature, and 800 F NaK coolant inlet temperature was 16.3 percent. After the performance tests the pump was operated without any difficulty at design point for 10,000 hours, and then a limited number of repeat performance tests were made. There was no appreciable change in pump performance after 10,000 hours of operation. A supplementary series of tests using the quasi-square wave power output of a dc to three-phase ac inverter showed that the pump would operate without difficulty at a frequency as low as 25 Hz, with little loss in efficiency.
Sharp, Carla; Kalpakci, Allison; Mellick, William; Venta, Amanda; Temple, Jeff R
2015-03-01
At least two leading developmental models of borderline personality disorder (BPD) emphasize the role of accurate reflection and understanding of internal states as significant to the development of BPD features (Fonagy, Int J Psycho-Anal 72:639-656, 1991; Linehan, Cognitive-behavioral treatment of borderline personality disorder, 1993). The current study used the construct of experiential avoidance (EA) to operationalize avoidance of internal states and sought to examine (1) the concurrent relations between EA and borderline features in a large and diverse community sample; and (2) the prospective relation between EA and borderline features over a 1-year follow-up, controlling for baseline levels of borderline features. N = 881 adolescents recruited from public schools in a large metropolitan area participated in baseline assessments and N = 730 completed follow-up assessments. Two main findings were reported. First, EA was associated with borderline features, depressive, and anxiety symptoms at the bivariate level, but when all variables were considered together, depression and anxiety no longer remained significantly associated with borderline features, suggesting that the relations among these symptom clusters may be accounted for by EA as a cross-cutting underlying psychological process. Second, EA predicted levels of borderline symptoms at 1-year follow-up, controlling for baseline levels of borderline symptoms, and symptoms of anxiety and depression. Results are interpreted against the background of developmental theories of borderline personality disorder.
NASA Astrophysics Data System (ADS)
Mojahedi, Mahdi; Shekoohinejad, Hamidreza
2018-02-01
In this paper, temperature distribution in the continuous and pulsed end-pumped Nd:YAG rod crystal is determined using nonclassical and classical heat conduction theories. In order to find the temperature distribution in crystal, heat transfer differential equations of crystal with consideration of boundary conditions are derived based on non-Fourier's model and temperature distribution of the crystal is achieved by an analytical method. Then, by transferring non-Fourier differential equations to matrix equations, using finite element method, temperature and stress of every point of crystal are calculated in the time domain. According to the results, a comparison between classical and nonclassical theories is represented to investigate rupture power values. In continuous end pumping with equal input powers, non-Fourier theory predicts greater temperature and stress compared to Fourier theory. It also shows that with an increase in relaxation time, crystal rupture power decreases. Despite of these results, in single rectangular pulsed end-pumping condition, with an equal input power, Fourier theory indicates higher temperature and stress rather than non-Fourier theory. It is also observed that, when the relaxation time increases, maximum amounts of temperature and stress decrease.
Höhner, Gesche; Teismann, Tobias; Willutzki, Ulrike
2014-02-01
Do women suffering from borderline symptomatology differ from women without these symptoms regarding their motives for body modifications?A sample of 289 women with body modifications were questioned about their tattoos, piercings and motives for body modifications as well as about symptoms of borderline personality disorder. Women with borderline symptomatology were compared to women without borderline symptomatology concerning the extent of and motives for body modification.The 2 groups showed no differences in regard to amount and extent of body modifications. The "borderline"-group considered individuality, coping and management of negative life-events to be more crucial reasons for body modification than the non-borderline females.The degree of a person's body modification is not a feasible indicator for psychopathological strain. Though, for people with borderline tendency body modification may serve as a coping strategy similar to self-injury. © Georg Thieme Verlag KG Stuttgart · New York.
[Borderline personality disorder and transsexualism].
Seikowski, Kurt; Gollek, Sabine; Harth, Wolfgang; Reinhardt, Michaela
2008-04-01
The study addresses the question whether, as often assumed, the symptoms of borderline personality disorders occur more frequently in transsexuals or not. We examined 164 transsexuals. The subjects completed the following questionnaires: The Borderline-Personality Inventory (BPI), the Freiburg Personality Inventory (FPI) and the Questionnaire for Assessment of One's Own Body (FbeK). In 80 % of all the examined transsexuals, there was evidence of symptoms of neither a borderline personality disorder nor of other personality disorders. If borderline symptoms occurred, they were predictable from the variables depressivity, low composure, low sociability and lack of confidence in relation to the external appearance. The data obtained refute the often-assumed increased relationship between borderline personality disorders and transsexuality. It should be assumed that a borderline personality disorder is primarily a psychiatric illness, while transsexuality is a disorder of gender identity in which secondary borderline symptoms may arise in some cases.
Suburban heat island effect in groundwater energy utilisation in Nordic climate - case study
NASA Astrophysics Data System (ADS)
Arola, Teppo
2017-04-01
We present the preliminary results from the initial thermogeological characterization of Finland's first-ever planned large-scale aquifer thermal energy storage (ATES) facility. The site is located in the Asko area (Lahti), at a latitude of 60°59'N. In particular, emphasis is put on the results from an aquifer's pumping test performed in July / August 2016 to investigate the potential implication of suburban heat island (SUHI) effect to ATES system on the naturally cold groundwater area. The site has been under geological investigation since July 2015. At a regional scale, the groundwater's natural temperature is about 5.8- 6°C. However, preliminary measurements during the investigations revealed that local groundwater temperature ranged between 7.5 to 8.7 °C in Asko area. The highest temperature was observed underneath buildings, suggesting that higher-than-average temperature is most likely influenced due to anthropogenic heat flux into the ground. The pumping test was performed for 39 days, of which 28 days with groundwater withdrawal and 11 days of heads recovery. The pumped volumes range from 350 to 540 m3/d leading the total volume of 10400 m3 of groundwater. Groundwater temperatures were continuously measured from pumping test well and two observation piezometers during the entire test. The results indicated that aquifer's temperature remained nearly constant being between 7.4 to 7.9 °C during the test period. Heat pulses with temperature variation of 0.1 to 0.3 °C were observed in the pumping well and nearest monitoring well (19 meters from pumping well) during the pumping test and recovery phase. We estimate that the pulses were due to rapidly changed groundwater flowing conditions and pulse indicate "new groundwater" flow to the well. Overall, the preliminary test suggests that groundwater temperature are expected to remain elevated during the ATES system operation. Elevated temperature due the SUHI effect increases groundwater heating potential significantly. Similarly groundwater cooling potential decrease but groundwater still constitutes an effective cooling energy reservoir because groundwater temperatures remain below air temperatures during the summer and the COP for cooling is extremely high. In Asko site SUHI effect has been recognised from the beginning of the project. Energy and economical calculations are based on anthropogenic influence to ground temperatures. More research, i.e. detailed groundwater thermogeological modelling, is needed to design the multi well ATES system based on elevated groundwater temperatures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schorghofer, Norbert; Aharonson, Oded, E-mail: norbert@hawaii.edu
2014-06-20
It has long been suggested that water ice can exist in extremely cold regions near the lunar poles, where sublimation loss is negligible. The geographic distribution of H-bearing regolith shows only a partial or ambiguous correlation with permanently shadowed areas, thus suggesting that another mechanism may contribute to locally enhancing water concentrations. We show that under suitable conditions, water molecules can be pumped down into the regolith by day-night temperature cycles, leading to an enrichment of H{sub 2}O in excess of the surface concentration. Ideal conditions for pumping are estimated and found to occur where the mean surface temperature ismore » below 105 K and the peak surface temperature is above 120 K. These conditions complement those of the classical cold traps that are roughly defined by peak temperatures lower than 120 K. On the present-day Moon, an estimated 0.8% of the global surface area experiences such temperature variations. Typically, pumping occurs on pole-facing slopes in small areas, but within a few degrees of each pole the equator-facing slopes are preferred. Although pumping of water molecules is expected over cumulatively large areas, the absolute yield of this pump is low; at best, a few percent of the H{sub 2}O delivered to the surface could have accumulated in the near-surface layer in this way. The amount of ice increases with vapor diffusivity and is thus higher in the regolith with large pore spaces.« less
Development of a proof of concept low temperature 4He Superfluid Magnetic Pump
NASA Astrophysics Data System (ADS)
Jahromi, Amir E.; Miller, Franklin K.
2017-03-01
We describe the development and experimental results of a proof of concept Superfluid Magnetic Pump in this work. This novel low temperature, no moving part pump can replace the existing bellows-piston driven 4He or 3He-4He mixture compressor/circulators used in various sub Kelvin refrigeration systems such as dilution, Superfluid pulse tube, Stirling, or active magnetic regenerative refrigerators. Due to the superior thermal transport properties of sub-Lambda 4He this pump can also be used as a simple circulator to distribute cooling over large surface areas. Our pump was experimentally shown to produce a maximum flow rate of 440 mg/s (averaged over cycle), 665 mg/s (peak) and produced a maximum pressure difference of 2323 Pa using only the more common isotope of helium, 4He. This pump worked in an ;ideal; thermodynamic state: The experimental results matched with the theoretical values predicted by a computer model. Pump curves were developed to map the performance of this pump. This successful demonstration will enable this novel pump to be implemented in suitable sub Kelvin refrigeration systems.
NASA Astrophysics Data System (ADS)
Qiu, Wei; Liu, Jianjun; Wang, Yuda; Yang, Yujing; Gao, Yuan; Lv, Pin; Jiang, Qiuli
2018-01-01
In this article a general theory of the coherent population oscillation effect in an erbium-doped fiber at room temperature is presented. We use dual pumping light waves with a simplified two-level system. Thus the time delay equations can be calculated from rate equations and the transmission equation. Using numerical simulation, in the case of dual-frequency pump light waves (1480 nm and 980 nm) with two directions, we analyze the influence of the pump power ratio on the group speed of light propagation. In addition, we compare slow light propagation with a single-pumping light and slow light propagation with a dual-pumping light at room temperature. The discussion shows that a larger time delay of slow light propagation can be obtained with a dual-frequency pumping laser. Compared to previous research methods, a dual-frequency laser pumped fiber with two directions is more controllable. Moreover, we conclude that the group velocity of light can be varied by changing the pump ratio.
High-temperature pump-motor assembly
NASA Technical Reports Server (NTRS)
Colker, C.; Waldron, W.
1971-01-01
Assembly pumps liquid sodium-potassium /NaK/ eutectic at 950 K for up to 20,000 hours. Design features include - high operating-temperature capability, zero leakage, process fluid lubricant/coolant, insulation system compatible with ionizing radiation environments, and reliability and long life without maintenance.
Gradient heating protocol for a diode-pumped alkali laser
NASA Astrophysics Data System (ADS)
Cai, He; Wang, You; Han, Juhong; Yu, Hang; Rong, Kepeng; Wang, Shunyan; An, Guofei; Wang, Hongyuan; Zhang, Wei; Wu, Peng; Yu, Qiang
2018-06-01
A diode-pumped alkali laser (DPAL) has gained rapid development in the recent years. Until now, the structure with single heater has been widely utilized to adjust the temperature of an alkali vapor cell in most of the literatures about DPALs. However, for an end-pumped DPAL using single heater, most pump energy is absorbed by the gain media near the entrance cell window because of the large absorption cross section of atomic alkali. As a result, the temperature in the pumping area around the entrance window will go up rapidly, especially in a case of high pumping density. The temperature rise would bring about some negative influences such as thermal effects and variations in population density. In addition, light scattering and window contamination aroused by the chemical reaction between the alkali vapor and the buffer gas will also affect the output performance of a DPAL system. To find a solution to these problems, we propose a gradient heating approach in which several heaters are tandem-set along the optical axis to anneal an alkali vapor cell. The temperature at the entrance window is adjusted to be lower than that of the other side. By using this novel scheme, one can not only achieve a homogeneous absorption of the pump energy along the cell axis, but also decrease the possibility of the window damage in a DPAL configuration. The theoretical simulation of the laser output features has been carried out for a configuration of multiple heaters. Additionally, the DPAL output performance under different gradient temperatures is also discussed in this paper. The conclusions might be helpful for development of a high-powered and high-beam-quality DPAL.
Broadbear, Jillian H; Nesci, Julian; Thomas, Rosemary; Thompson, Katherine; Beatson, Josephine; Rao, Sathya
2016-12-01
Residential patients diagnosed with borderline personality disorder were evaluated to determine whether borderline personality disorder-focused psychotherapy reduced prescribing, personality disorder and co-morbid symptom severity. Psychotropic prescriptions were measured at admission, discharge and 1 year later in 74 female participants with one or more personality disorder diagnosis and co-morbid mood disorders. Changes in pharmacotherapy were examined in the context of improvements in borderline personality disorder and/or co-morbid disorder symptom severity. Residential treatment included individual and group psychotherapy for borderline personality disorder. The Structured Clinical Interview for DSM-IV was used to confirm the borderline personality disorder diagnosis and associated co-morbid conditions. The Beck Depression Inventory was completed at each time point. A significant reduction in the incidence and severity of self-rated depression as well as clinician assessed personality disorder, including borderline personality disorder, was accompanied by a reduction in prescription of psychoactive medications. Three to six months of intensive borderline personality disorder-specific psychotherapy showed lasting benefit with regard to symptom severity of personality disorders (borderline personality disorder in particular) as well as depressive symptoms. This improvement corresponded with a reduction in prescriptions for psychoactive medications, which is consistent with current thinking regarding treatment for borderline personality disorder. © The Royal Australian and New Zealand College of Psychiatrists 2016.
Gratz, Kim L; Tull, Matthew T; Reynolds, Elizabeth K; Bagge, Courtney L; Latzman, Robert D; Daughters, Stacey B; Lejuez, C W
2009-01-01
Although research has been conducted on the course, consequences, and correlates of borderline personality disorder (BPD), little is known about its emergence in childhood, and no studies have examined the extent to which theoretical models of the pathogenesis of BPD in adults are applicable to the correlates of borderline personality symptoms in children. The goal of this study was to examine the interrelationships between two BPD-relevant personality traits (affective dysfunction and disinhibition), self- and emotion-regulation deficits, and childhood borderline personality symptoms among 263 children aged 9 to 13. We predicted that affective dysfunction, disinhibition, and their interaction would be associated with childhood borderline personality symptoms, and that self- and emotion-regulation deficits would mediate these relationships. Results provided support for the roles of both affective dysfunction and disinhibition (in the form of sensation seeking) in childhood borderline personality symptoms, as well as their hypothesized interaction. Further, both self- and emotion-regulation deficits partially mediated the relationship between affective dysfunction and childhood borderline personality symptoms. Finally, results provided evidence of different gender-based pathways to childhood borderline personality symptoms, suggesting that models of BPD among adults are more relevant to understanding the factors associated with borderline personality symptoms among girls than boys.
Mathematical model development and simulation of heat pump fruit dryer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Achariyaviriya, S.; Soponronnarit, S.; Terdyothin, A.
2000-01-01
A mathematical model of a heat pump fruit dryer was developed to study the performance of heat pump dryers. Using the moisture content of papaya glace drying, the refrigerant temperature at the evaporator and condenser and the performance, was verified. It was found that the simulated results using closed loop heat pump dryer were close to the experimental results. The criteria for evaluating the performance were specific moisture extraction rate and drying rate. The results showed that ambient conditions affected significantly on the performance of the open loop dryer and the partially closed loop dryer. Also, the fraction of evaporatormore » bypass air affected markedly the performance of all heat pump dryers. In addition, it was found that specific air flow rate and drying air temperature affected significantly the performance of all heat pump dryers.« less
Spectra- and temperature-dependent dynamics of directly end-pumped holmium lasers
NASA Astrophysics Data System (ADS)
Ji, Encai; Shen, Yijie; Nie, Mingming; Fu, Xing; Liu, Qiang
2017-04-01
We develop a theoretical model with high accuracy for directly end-pumped Ho3+ laser system considering the influences of ground-state depletion, energy transfer up-conversion, temperature-dependent cross sections, and pump spectra shift. The heat generation in our model is precisely evaluated by calculating the transition rates of non-radiation relaxation processes among manifolds and in-band relaxation processes based on a detailed analysis of energy levels structure of holmium ions. A spatial dynamic thermal iteration method, just developed by our group, is applied to describe the coupled influences between spatial thermal effects and pump spectra. This model is verified to both adapt to the narrow-band good beam-quality pumped case and the broad-band bad beam-quality pumped case, which is in accordance with our previous reported experimental results.
A handy liquid metal based electroosmotic flow pump.
Gao, Meng; Gui, Lin
2014-06-07
A room temperature liquid metal based electroosmotic flow (EOF) pump has been proposed in this work. This low-cost EOF pump is convenient for both fabrication and integration. It utilizes polydimethylsiloxane (PDMS) microchannels filled with the liquid-metal as non-contact pump electrodes. The electrode channels are fabricated symmetrically to both sides of the pumping channel, having no contact with the pumping channel. To test the pumping performance of the EOF pump, the mean flow velocities of the fluid (DI water) in the EOF pumps were experimentally measured by tracing the fluorescent microparticles in the flow. To provide guidance for designing a low voltage EOF pump, parametric studies on dimensions of the electrode and pumping channels were performed in this work. According to the experimental results, the pumping speed can reach 5.93 μm s(-1) at a driving voltage of only 1.6 V, when the gap between the electrode and the pumping channel is 20 μm. Injecting a room temperature liquid metal into microchannels can provide a simple, rapid, low-cost but accurately self-aligned way to fabricate microelectrodes for EOF pumps, which is a promising method to achieve the miniaturization and integration of the EOF pump in microfluidic systems. The non-contact liquid electrodes have no influence on the fluid in the pumping channel when pumping, reducing Joule heat generation and preventing gas bubble formation at the surface of electrodes. The pump has great potential to drive a wide range of fluids, such as drug reagents, cell suspensions and biological macromolecule solutions.
Ryan, Jaymee; Graham, Anne; Nelson, Barnaby; Yung, Alison
2017-06-01
The association between borderline personality disorder and the ultra high risk (UHR) for psychosis state is unclear. The following study aimed to investigate the type of attenuated psychotic symptoms and prevalence of borderline personality pathology in a sample of UHR young people. Additionally, the study aimed to explore whether borderline personality pathology influenced the transition rate to psychosis. Medical records from Orygen Youth Health between 2007 and 2009 were examined. There were 180 patients who met UHR criteria and were included for analysis. Most patients were females (62.8%) and age ranged from 15 to 24 years. A quarter (25.2%) of UHR patients endorsed items consistent with borderline personality pathology. UHR patients with borderline personality pathology experienced a range of attenuated psychotic symptoms and could not be statistically differentiated from UHR patients with less significant or without borderline personality pathology. Borderline personality pathology did not increase or decrease the risk of developing a psychotic disorder. The absence of depression was the only predictor of psychosis. Many UHR patients present with concurrent borderline personality features. The psychotic experiences reported by UHR patients with borderline personality features were not limited to paranoid ideation, supporting the idea that borderline personality disorder may include a wider range of psychotic symptoms than previously thought. It is further possible that the psychotic symptoms experienced in this group could also be indicative of an emerging psychotic disorder. © 2015 Wiley Publishing Asia Pty Ltd.
You, Dokyoung S; Meagher, Mary W
2017-01-01
Individuals with greater borderline personality features may be vulnerable to chronic pain. Because pain is an unpleasant sensory and emotional experience, affect dysregulation as the core personality feature may be linked to pain hypersensitivity. Studies have found that greater borderline features are associated with increased intensity in clinical and experimental pain, and that depression mediates this increase. The current study further examined the association between borderline features and heat pain sensitivity, the contribution of affect dysregulation and the other borderline personality factors (identity problems, negative relationships, self-harming/impulsivity) to the association, and depression as a mediator. Additionally, we examined whether blunted sympathetic responses mediate the association between borderline features and temporal summation of second pain (TSSP). Thermal pain threshold, thermal TSSP and aftersensations pain were assessed in 79 healthy individuals with varying degrees of borderline features. TSSP is a proxy measure for central sensitization and refers to the gradual increase in pain to repeated nociceptive stimuli. A regression analysis showed that greater borderline features predicted greater TSSP (β = .22, p = .050, R 2 = .05). Borderline features were unrelated to pain threshold and TSSP decay. A stepwise regression showed greater TSSP in individuals with greater borderline features was accounted for by the negative relationships factor rather than the affect dysregulation factor. The results of mediational analyses showed depression and blunted sympathetic skin conductance responses mediated the positive association between TSSP and borderline features.
Distel, Marijn A; Trull, Timothy J; Willemsen, Gonneke; Vink, Jacqueline M; Derom, Catherine A; Lynskey, Michael; Martin, Nicholas G; Boomsma, Dorret I
2009-12-15
Recently, the nature of personality disorders and their relationship with normal personality traits has received extensive attention. The five-factor model (FFM) of personality, consisting of the personality traits neuroticism, extraversion, openness to experience, agreeableness, and conscientiousness, is one of the proposed models to conceptualize personality disorders as maladaptive variants of continuously distributed personality traits. The present study examined the phenotypic and genetic association between borderline personality and FFM personality traits. Data were available for 4403 monozygotic twins, 4425 dizygotic twins, and 1661 siblings from 6140 Dutch, Belgian, and Australian families. Broad-sense heritability estimates for neuroticism, agreeableness, conscientiousness, extraversion, openness to experience, and borderline personality were 43%, 36%, 43%, 47%, 54%, and 45%, respectively. Phenotypic correlations between borderline personality and the FFM personality traits ranged from .06 for openness to experience to .68 for neuroticism. Multiple regression analyses showed that a combination of high neuroticism and low agreeableness best predicted borderline personality. Multivariate genetic analyses showed the genetic factors that influence individual differences in neuroticism, agreeableness, conscientiousness, and extraversion account for all genetic liability to borderline personality. Unique environmental effects on borderline personality, however, were not completely shared with those for the FFM traits (33% is unique to borderline personality). Borderline personality shares all genetic variation with neuroticism, agreeableness, conscientiousness, and extraversion. The unique environmental influences specific to borderline personality may cause individuals with a specific pattern of personality traits to cross a threshold and develop borderline personality.
Armenti, Nicholas A; Babcock, Julia C
2018-04-01
Individuals with borderline personality features may be susceptible to react to situational stressors with negative and interpersonally maladaptive emotionality (e.g., anger) and aggression. The current study attempted to test two moderated mediation models to investigate dispositional risk factors associated with borderline personality features and intimate partner violence (IPV). Results from an experimental rejection induction paradigm were examined using moderated regression to observe contextual reactions to imagined romantic rejection from a current romantic partner among individuals with borderline personality features. An ethnically diverse sample of 218 undergraduates at a large public university in the southwestern United States was recruited. Participants responded to demographic questions and self-report measures, and engaged in an experimental rejection induction paradigm. Borderline personality features was positively associated with rejection sensitivity, physical assault, and psychological aggression. Contrary to initial hypotheses, rejection sensitivity did not serve as a mediator of the relations between borderline personality features and physical assault and psychological aggression. However, trait anger mediated the relation between borderline personality features and psychological aggression. As such, trait anger may be an important explanatory variable in the relation between borderline personality features and psychological aggression specifically. Results of the rejection induction paradigm indicated that, for individuals who were asked to imagine an ambiguous rejection, the relation between borderline personality features and state anger post-rejection was strengthened. For individuals who imagined a critical rejection, there was no significant relation between borderline personality features and state anger post-rejection. Findings suggest that trait anger may be an important dispositional factor in the link between borderline personality features and IPV. In addition, contextual factors, such as ambiguous rejection by an intimate partner, may be especially relevant in activating anger or aggression in individuals with borderline personality features.
Liang, Qiangbing; Yang, Baodong; Zhang, Tiancai; Wang, Junmin
2010-06-21
By monitoring the transmission of probe laser beam (also served as coupling laser beam) which is locked to a cycling hyperfine transition of cesium D(2) line, while pumping laser is scanned across cesium D(1) or D(2) lines, the single-resonance optical pumping (SROP) spectra are obtained with atomic vapor cell. The SROP spectra indicate the variation of the zero-velocity atoms population of one hyperfine fold of ground state, which is optically pumped into another hyperfine fold of ground state by pumping laser. With the virtue of Doppler-free linewidth, high signal-to-noise ratio (SNR), flat background and elimination of crossover resonance lines (CRLs), the SROP spectra with atomic vapor cell around room temperature can be employed to measure dressed-state splitting of ground state, which is normally detected with laser-cooled atomic sample only, even if the dressed-state splitting is much smaller than the Doppler-broaden linewidth at room temperature.
A fermentation-powered thermopneumatic pump for biomedical applications.
Ochoa, Manuel; Ziaie, Babak
2012-10-21
We present a microorganism-powered thermopneumatic pump that utilizes temperature-dependent slow-kinetics gas (carbon dioxide) generating fermentation of yeast as a pressure source. The pump consists of stacked layers of polydimethylsiloxane (PDMS) and a silicon substrate that form a drug reservoir, and a yeast-solution-filled working chamber. The pump operates by the displacement of a drug due to the generation of gas produced via yeast fermentation carried out at skin temperatures. The robustness of yeast allows for long shelf life under extreme environmental conditions (50 °C, >250 MPa, 5-8% humidity). The generation of carbon dioxide is a linear function of time for a given temperature, thus allowing for a controlled volume displacement. A polymeric prototype (dimensions 15 mm × 15 mm × 10 mm) with a slow flow rate of <0.23 μL min(-1) and maximum backpressure of 5.86 kPa capable of continuously pumping for over two hours is presented and characterized.
A new concept for solar pumped lasers
NASA Technical Reports Server (NTRS)
Christiansen, W. H.
1978-01-01
A new approach is proposed in which an intermediate body heated by sunlight is used as the pumping source for IR systems, i.e., concentration solar radiation is absorbed and reradiated via an intermediate blackbody. This body is heated by focused sunlight to a high temperature and its heat losses are engineered to be small. The cooled laser tube (or tubes) is placed within the cavity and is pumped by it. The advantage is that the radiation spectrum is like a blackbody at the intermediate temperature and the laser medium selectively absorbs this light. Focusing requirements, heat losses, and absorption bandwidths of laser media are examined, along with energy balance and potential efficiency. The results indicate that for lasers pumped through an IR absorption spectrum, the use of an intermediate blackbody offers substantial and important advantages. The loss in radiative intensity for optical pumping by a lower-temperature body is partly compensated by the increased solid angle of exposure to the radiative environment.
Micromachined evaporators for AMTEC cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Izenson, M.G.; Crowley, C.J.
1996-12-31
To achieve high cell efficiency and reliability, the capillary pumping system for Alkali Metal Thermal to Electric Conversion (AMTEC) must have three key characteristics: (1) very small pores to achieve a high capillary pumping head, (2) high permeability for the flow of liquid sodium to minimize internal losses, and (3) be made from a material that is exceptionally stable at high temperatures in a sodium environment. The authors have developed micromachining techniques to manufacture high performance evaporators for AMTEC cells. The evaporators have been fabricated from stainless steel, molybdenum, and a niobium alloy (Nb-1Zr). The regular, micromachined structure leads tomore » very high capillary pumping head with high permeability for liquid flow. Data from tests performed with common fluids at room temperature characterize the capillary pumping head and permeability of these structures. Three micromachined evaporators have been built into AMTEC cells and operated at temperatures up to 1,100 K. Results from these tests confirm the excellent pumping capabilities of the micromachined evaporators.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thariyan, Mathew P.; Ananthanarayanan, Vijaykumar; Bhuiyan, Aizaz H.
2010-07-15
Dual-pump coherent anti-Stokes Raman scattering (CARS) is used to measure temperature and species profiles in representative non-premixed and partially-premixed CH{sub 4}/O{sub 2}/N{sub 2} flames. A new laser system has been developed to generate a tunable single-frequency beam for the second pump beam in the dual-pump N{sub 2}-CO{sub 2} CARS process. The second harmonic output ({proportional_to}532 nm) from an injection-seeded Nd:YAG laser is used as one of the narrowband pump beams. The second single-longitudinal-mode pump beam centered near 561 nm is generated using an injection-seeded optical parametric oscillator, consisting of two non-linear {beta}-BBO crystals, pumped using the third harmonic output ({proportional_to}355more » nm) of the same Nd:YAG laser. A broadband dye laser (BBDL), pumped using the second harmonic output of an unseeded Nd:YAG laser, is employed to produce the Stokes beam centered near 607 nm with full-width-at-half-maximum of {proportional_to}250 cm{sup -1}. The three beams are focused between two opposing nozzles of a counter-flow burner facility to measure temperature and major species concentrations in a variety of CH{sub 4}/O{sub 2}/N{sub 2} non-premixed and partially-premixed flames stabilized at a global strain rate of 20 s{sup -1} at atmospheric-pressure. For the non-premixed flames, excellent agreement is observed between the measured profiles of temperature and CO{sub 2}/N{sub 2} concentration ratios with those calculated using an opposed-flow flame code with detailed chemistry and molecular transport submodels. For partially-premixed flames, with the rich side premixing level beyond the stable premixed flame limit, the calculations overestimate the distance between the premixed and the non-premixed flamefronts. Consequently, the calculated temperatures near the rich, premixed flame are higher than those measured. Accurate prediction of the distance between the premixed and the non-premixed flames provides an interesting challenge for future computations. (author)« less
Yoshida, Hiroyuki; Kuwana, Akemi; Shibata, Hiroko; Izutsu, Ken-Ichi; Goda, Yukihiro
2016-06-01
To clarify the effects of pump pulsation and flow-through cell (FTC) dissolution system settings on the hydrodynamic properties and dissolution profiles of model formulations. Two FTC systems with different cell temperature control mechanisms were used. Particle image velocimetry (PIV) was used to analyze the hydrodynamic properties of test solutions in the flow-through dissolution test cell. Two pulsation pumps (semi-sine, full-sine) and a non-pulsatile pump were used to study the effects of varied flows on the dissolution profiles of United States Pharmacopeia standard tablets. PIV analysis showed periodic changes in the aligned upward fluid flow throughout the dissolution cell that was designed to reduce the temperature gradient during pump pulsation (0.5 s/pulse). The maximum instantaneous flow from the semi-sine pump was higher than that of the full-sine pump under all conditions. The flow from the semi-sine wave pump showed faster dissolution of salicylic acid and prednisone tablets than those from other pumps. The semi-sine wave pump flow showed similar dissolution profiles in the two FTC systems. Variations in instantaneous fluid flow caused by pump pulsation that meets the requirements of pharmacopoeias are a factor that affects the dissolution profiles of tablets in FTC systems.
Dual-pump CARS of Air in a Heated Pressure Vessel up to 55 Bar and 1300 K
NASA Technical Reports Server (NTRS)
Cantu, Luca; Gallo, Emanuela; Cutler, Andrew D.; Danehy, Paul M.
2014-01-01
Dual-pump Coherent anti-Stokes Raman scattering (CARS) measurements have been performed in a heated pressure vessel at NASA Langley Research Center. Each measurement, consisting of 500 single shot spectra, was recorded at a fixed location in dry air at various pressures and temperatures, in a range of 0.03-55×10(exp 5) Pa and 300-1373 K, where the temperature was varied using an electric heater. The maximum output power of the electric heater limited the combinations of pressures and temperatures that could be obtained. Charts of CARS signal versus temperature (at constant pressure) and signal versus pressure (at constant temperature) are presented and fit with an empirical model to validate the range of capability of the dual-pump CARS technique; averaged spectra at different conditions of pressure and temperature are also shown.
Thermal Analysis of the PediaFlow pediatric ventricular assist device.
Gardiner, Jeffrey M; Wu, Jingchun; Noh, Myounggyu D; Antaki, James F; Snyder, Trevor A; Paden, David B; Paden, Brad E
2007-01-01
Accurate modeling of heat dissipation in pediatric intracorporeal devices is crucial in avoiding tissue and blood thermotrauma. Thermal models of new Maglev ventricular assist device (VAD) concepts for the PediaFlow VAD are developed by incorporating empirical heat transfer equations with thermal finite element analysis (FEA). The models assume three main sources of waste heat generation: copper motor windings, active magnetic thrust bearing windings, and eddy currents generated within the titanium housing due to the two-pole motor. Waste heat leaves the pump by convection into blood passing through the pump and conduction through surrounding tissue. Coefficients of convection are calculated and assigned locally along fluid path surfaces of the three-dimensional pump housing model. FEA thermal analysis yields a three-dimensional temperature distribution for each of the three candidate pump models. Thermal impedances from the motor and thrust bearing windings to tissue and blood contacting surfaces are estimated based on maximum temperature rise at respective surfaces. A new updated model for the chosen pump topology is created incorporating computational fluid dynamics with empirical fluid and heat transfer equations. This model represents the final geometry of the first generation prototype, incorporates eddy current heating, and has 60 discrete convection regions. Thermal analysis is performed at nominal and maximum flow rates, and temperature distributions are plotted. Results suggest that the pump will not exceed a temperature rise of 2 degrees C during normal operation.
Kalapotharakos, Grigorios; Högberg, Thomas; Bergfeldt, Kjell; Borgfeldt, Christer
2016-04-01
We conducted an evaluation of incidence and survival of women with borderline ovarian tumors in Sweden. All women diagnosed with borderline ovarian tumor in the Swedish Cancer Register 1960-2007 (n = 6252) combined with follow up in the Swedish Death Registry to 1 July 2009 were included. Estimation of age-standardized relative survival rate according to time periods for diagnosis. The incidence of borderline ovarian tumors increased during the study period, with a steep increase during the 1980s. The age standardized 5-year relative survival including all borderline tumors diagnosed 2000-07 was 97% (95% CI 92-99%). In women aged ≤64 years, the 10-year relative survival related to age at diagnosis of borderline tumors ranged from 95 to 98% and was 89% in women aged 65-74 years. In a multivariable analysis including age and decade of diagnosis relative survival for every decade increased. The 10-year relative survival in women with mucinous and serous borderline tumors did not differ significantly (p = 0.121). Results of the present study are reassuring about long-term survival in women with borderline ovarian tumors. The age-standardized relative survival rate increased across time periods for diagnosis. There was no difference in long-term survival between mucinous and serous borderline ovarian tumors. © 2016 Nordic Federation of Societies of Obstetrics and Gynecology.
Gratz, Kim L.; Tull, Matthew T.; Reynolds, Elizabeth K.; Bagge, Courtney L.; Latzman, Robert D.; Daughters, Stacey B.; Lejuez, C. W.
2010-01-01
Although research has been conducted on the course, consequences, and correlates of borderline personality disorder (BPD), little is known about its emergence in childhood, and no studies have examined the extent to which theoretical models of the pathogenesis of BPD in adults are applicable to the correlates of borderline personality symptoms in children. The goal of this study was to examine the interrelationships between two BPD-relevant personality traits (affective dysfunction and disinhibition), self- and emotion regulation deficits, and childhood borderline personality symptoms among 263 children aged 9 to 13. We predicted that affective dysfunction, disinhibition, and their interaction would be associated with childhood borderline personality symptoms, and that self- and emotion-regulation deficits would mediate these relationships. Results provided support for the roles of both affective dysfunction and disinhibition (in the form of sensation seeking) in childhood borderline personality symptoms, as well as their hypothesized interaction. Further, both self- and emotion-regulation deficits partially mediated the relationship between affective dysfunction and childhood borderline personality symptoms. Finally, results provided evidence of different gender-based pathways to childhood borderline personality symptoms, suggesting that models of BPD among adults are more relevant to understanding the factors associated with borderline personality symptoms among girls than boys. PMID:19825268
Is research on borderline personality disorder underfunded by the National Institute of Health?
Zimmerman, Mark; Gazarian, Doug
2014-12-30
The relationship between bipolar disorder and borderline personality disorder has generated intense interest. Similar to patients with bipolar disorder, patients with borderline personality disorder are frequently hospitalized, are chronically unemployed, abuse substances, attempt and commit suicide. However, one significant difference between the two disorders is that patients with borderline personality disorder are often viewed negatively by mental health professionals. In the present paper we examined whether this negative bias against borderline personality disorder might be reflected in the level of research funding on the disorder. We searched the National Institute of Health (NIH) Research Portfolio Online Portfolio Reporting Tool (RePORT) for the past 25 years and compared the number of grants funded and the total amount of funding for borderline personality disorder and bipolar disorder. The yearly mean number of grants receiving funding was significantly higher for bipolar disorder than for borderline personality disorder. Results were the same when focusing on newly funded grants. For every year since 1990 more grants were funded for bipolar disorder than borderline personality disorder. Summed across all 25 years, the level of funding for bipolar disorder was more than 10 times greater than the level of funding for borderline personality disorder ($622 million vs. $55 million). These findings suggest that the level of NIH research funding for borderline personality disorder is not commensurate with the level of psychosocial morbidity, mortality, and health expenditures associated with the disorder.
NASA Astrophysics Data System (ADS)
Granovskii, Mikhail; Dincer, Ibrahim; Rosen, Marc A.; Pioro, Igor
Increases in the power generation efficiency of nuclear power plants (NPPs) are mainly limited by the permissible temperatures in nuclear reactors and the corresponding temperatures and pressures of the coolants in reactors. Coolant parameters are limited by the corrosion rates of materials and nuclear-reactor safety constraints. The advanced construction materials for the next generation of CANDU reactors, which employ supercritical water (SCW) as a coolant and heat carrier, permit improved “steam” parameters (outlet temperatures up to 625°C and pressures of about 25 MPa). An increase in the temperature of steam allows it to be utilized in thermochemical water splitting cycles to produce hydrogen. These methods are considered by many to be among the most efficient ways to produce hydrogen from water and to have advantages over traditional low-temperature water electrolysis. However, even lower temperature water splitting cycles (Cu-Cl, UT-3, etc.) require an intensive heat supply at temperatures higher than 550-600°C. A sufficient increase in the heat transfer from the nuclear reactor to a thermochemical water splitting cycle, without jeopardizing nuclear reactor safety, might be effectively achieved by application of a heat pump, which increases the temperature of the heat supplied by virtue of a cyclic process driven by mechanical or electrical work. Here, a high-temperature chemical heat pump, which employs the reversible catalytic methane conversion reaction, is proposed. The reaction shift from exothermic to endothermic and back is achieved by a change of the steam concentration in the reaction mixture. This heat pump, coupled with the second steam cycle of a SCW nuclear power generation plant on one side and a thermochemical water splitting cycle on the other, increases the temperature of the “nuclear” heat and, consequently, the intensity of heat transfer into the water splitting cycle. A comparative preliminary thermodynamic analysis is conducted of the combined system comprising a SCW nuclear power generation plant and a chemical heat pump, which provides high-temperature heat to a thermochemical water splitting cycle for hydrogen production. It is concluded that the proposed chemical heat pump permits the utilization efficiency of nuclear energy to be improved by at least 2% without jeopardizing nuclear reactor safety. Based on this analysis, further research appears to be merited on the proposed advanced design of a nuclear power generation plant combined with a chemical heat pump, and implementation in appropriate applications seems worthwhile.
Bolia, Ioanna K; Briggs, Karen K; Locks, Renato; Chahla, Jorge; Utsunomiya, Hajime; Philippon, Marc J
2018-05-02
To compare the prevalence, size, and location of Outerbridge grade III and IV cartilage defects on the femoral head and acetabulum between patients with borderline acetabular dysplasia and patients with non-borderline dysplasia who underwent hip arthroscopy for femoroacetabular impingement (FAI). Patients aged 18 years or older who underwent primary hip arthroscopy for correction of FAI and labral repair from November 2005 to April 2016 were included. We excluded patients with previous hip surgery, a radiographic hip joint space of 2 mm or less, and/or a lateral center-edge angle (LCEA) of less than 20° or greater than 40°. The study patients were divided into 2 groups based on the LCEA on the anteroposterior pelvic radiograph: Patients with an LCEA between 20° and 25° were included in the borderline group, and patients with an LCEA between 25° and 40° were included in the non-borderline group. The prevalence, size, and location of Outerbridge grade III and IV chondral lesions on the femoral head and acetabulum were recorded intraoperatively. Comparisons between groups were performed with the Mann-Whitney U test for nonparametric testing and the t test for data that were normally distributed. Data were analyzed to calculate odds ratios associated with the various factors. In total, 2,429 patients (1,114 women and 1,315 men) met the inclusion criteria. The borderline group consisted of 305 patients (150 men and 155 women), whereas the non-borderline dysplasia group comprised 2,124 patients (1,165 men and 959 women). Outerbridge grade III and IV chondral lesions were found on the femoral head in 118 patients with borderline dysplasia (39%) and 127 patients with non-borderline dysplasia (6%) and on the acetabulum in 132 patients with borderline dysplasia (43%) and 874 patients with non-borderline dysplasia (41%). Patients with borderline dysplasia were 10 times more likely (95% confidence interval, 7.3-13.4; P < .001) to have a grade III or IV cartilage defect on the weight-bearing surface of the femoral head (P < .001) than patients with non-borderline dysplasia. On the acetabular side, no difference in the prevalence of severe cartilage damage was detected between the 2 groups (P = .588). The size of chondral damage was significantly greater in patients with borderline dysplasia on the acetabulum (P = .039) compared with the non-borderline dysplasia group. Patients with FAI and borderline dysplasia are at higher risk of having Outerbridge grade III and IV chondral damage on the femoral head than patients with non-borderline dysplastic hips. Borderline dysplastic hips also presented with significantly larger chondral defects on the acetabular surface. Level III, retrospective comparative study. Copyright © 2018 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
The mechanical design of a vapor compressor for a heat pump to be used in space
NASA Technical Reports Server (NTRS)
Berner, F.; Oesch, H.; Goetz, K.; Savage, C. J.
1982-01-01
A heat pump developed for use in Spacelab as a stand-alone refrigeration unit as well as within a fluid loop system is discussed. It will provide an active thermal control for payloads. Specifications for the heat pump were established: (1) heat removal rates at the source; (2) heat source temperatures from room temperature; (3) heat-sink fluid temperatures at condenser inlet; and (4) minimum power consumption. A reversed Carnot cycle heat pump using Freon 12 as working fluid incorporating a one-cylinder reciprocating compressor was selected. The maximum crankshaft speed was fixed relatively high at 100 rpm. The specified cooling rates then made it necessary to select a cylinder volume of 10 cu cm, which was obtained with a bore of 40 mm and a stroke of 8 mm.
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
40 CFR 91.424 - Dilute sampling procedure-CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
... temperature at CVS pump inlet PTI °C ±1.11 °C Pressure depression at CVS pump inlet PPI kPa ±0.055 kPa...) Reset the restrictor valve to a more restricted condition in an increment of pump inlet depression that...=Absolute pump inlet pressure, kPa. =PP−PPI Where: PP=barometric pressure, kPa. PPI=Pump inlet depression, k...
2015-09-01
Transfer Pump Liner before Testing with 25/75 ATJ/JP-8 Fuel with 9-ppm CI/LI...46 Figure 26. Pump SN:16756534 Transfer Pump Liner with 251-hours Testing with 25/75 ATJ/JP-8 Fuel...Transfer Pump Liner before Testing with 25/75 ATJ/JP-8 Fuel with 9-ppm CI/LI
ERIC Educational Resources Information Center
Drass, Jessica Masino
2015-01-01
Art therapy has shown benefits for people with borderline personality disorder and borderline personality traits by alleviating interpersonal difficulties such as affect regulation, an unstable sense of self, self-injurious behaviors, and suicidal ideation. Borderline personality disorder is currently viewed as a trauma spectrum disorder, because…
Three stage vacuum system for ultralow temperature installation
NASA Astrophysics Data System (ADS)
Das, N. K.; Pradhan, J.; Naser, Md Z. A.; Mandal, B. Ch; Roy, A.; Kumar, P.; Mallik, C.; Bhandari, R. K.
2012-11-01
We use a three stage vacuum system for developing a dilution fridge at VECC, Kolkata. We aim at achieving a cooling power of 20μW at 100mK for various experiments especially in the field of condensed matter and nuclear physics. The system is essentially composed of four segments-bath cryostat, vacuum system, dilution insert and 3He circulation circuit. Requirement of vacuum system at different stages are different. The vacuum system for cryostat and for internal vacuum chamber located within the helium bath is a common turbo molecular pump backed by scroll pump as to maintain a vacuum ~10-6mbar. For bringing down the temperature of the helium evaporator, we use a high throughput Roots pump backed by a dry pump. The pumping system for 3He distillation chamber (still) requires a high pumping speed, so a turbo drag pump backed by a scroll pump has been installed. As the fridge use precious 3He gas for operation, the entire system has been made to be absolutely leak proof with respect to the 3He gas.
NASA Astrophysics Data System (ADS)
Pang, Suh Chyn; Masjuki, Haji Hassan; Kalam, Md. Abul; Hazrat, Md. Ali
2014-01-01
Automotive designers should design a robust engine cooling system which works well in both normal and severe driving conditions. When vehicles are keyed-off suddenly after some distance of hill-climbing driving, the coolant temperature tends to increase drastically. This is because heat soak in the engine could not be transferred away in a timely manner, as both the water pump and cooling fan stop working after the vehicle is keyed-off. In this research, we aimed to visualize the coolant temperature trend over time before and after the vehicles were keyed-off. In order to prevent coolant temperature from exceeding its boiling point and jeopardizing engine life, a numerical model was further tested with prolonged fan and/or water pump operation after keying-off. One dimensional thermal-fluid simulation was exploited to model the vehicle's cooling system. The behaviour of engine heat, air flow, and coolant flow over time were varied to observe the corresponding transient coolant temperatures. The robustness of this model was proven by validation with industry field test data. The numerical results provided sensible insights into the proposed solution. In short, prolonging fan operation for 500 s and prolonging both fan and water pump operation for 300 s could reduce coolant peak temperature efficiently. The physical implementation plan and benefits yielded from implementation of the electrical fan and electrical water pump are discussed.
NASA Astrophysics Data System (ADS)
Fischer, M.; Sperlich, A.; Kraus, H.; Ohshima, T.; Astakhov, G. V.; Dyakonov, V.
2018-05-01
We investigate the pump efficiency of silicon-vacancy-related spins in silicon carbide. For a crystal inserted into a microwave cavity with a resonance frequency of 9.4 GHz, the spin population inversion factor of 75 with the saturation optical pump power of about 350 mW is achieved at room temperature. At cryogenic temperature, the pump efficiency drastically increases, owing to an exceptionally long spin-lattice relaxation time exceeding one minute. Based on the experimental results, we find realistic conditions under which a silicon carbide maser can operate in continuous-wave mode and serve as a quantum microwave amplifier.
NASA Astrophysics Data System (ADS)
M, H. Moghtader Dindarlu; M Kavosh, Tehrani; H, Saghafifar; A, Maleki
2015-12-01
In this paper, according to the temperature and strain distribution obtained by considering the Gaussian pump profile and dependence of physical properties on temperature, we derive an analytical model for refractive index variations of the diode side-pumped Nd:YAG laser rod. Then we evaluate this model by numerical solution and our maximum relative errors are 5% and 10% for variations caused by thermo-optical and thermo-mechanical effects; respectively. Finally, we present an analytical model for calculating the focal length of the thermal lens and spherical aberration. This model is evaluated by experimental results.
NASA Astrophysics Data System (ADS)
Chen, G. B.; Zhong, Y. K.; Zheng, X. L.; Li, Q. F.; Xie, X. M.; Gan, Z. H.; Huang, Y. H.; Tang, K.; Kong, B.; Qiu, L. M.
2003-12-01
A novel gas-phase inlet configuration in the natural circulation system instead of the liquid-phase inlet is introduced to cool down a cryogenic pump system from room temperature to cryogenic temperatures, effectively. The experimental apparatus is illustrated and test process is described. Heat transfer and pressure drop data during the cool-down process are recorded and portrayed. By contrast with liquid-phase inlet configuration, experimental results demonstrate that the natural circulation with the gas-phase inlet configuration is an easier and more controllable way to cool down the pump system and maintain it at cryogenic temperatures.
Borderline personality disorder: study in adolescence.
James, A; Berelowitz, M; Vereker, M
1996-04-01
The study of the presentation, symptomatology and family characteristics of an exclusively adolescent sample of patients with borderline personality disorder (BPD) was undertaken. Twenty-four cases of borderline personality disorder, 20 females, 4 males, identified using chart review and meeting the criteria of the Diagnostic Interview for Borderlines (DIB) and DSM III-R, were matched with psychiatric controls. Adolescents with borderline personality disorder were found to have high rates of affective symptomatology with Axis I diagnosis of major depressive disorder MDD (DSM-III-R), and high rates of interpersonal psychopathology, i.e., manipulation, devaluation, and a pervasive sense of boredom. The latter seem to be characteristic as for adults with borderline personality disorder. The families were particularly angry and volatile.
NASA Astrophysics Data System (ADS)
Kohmoto, T.; Moriyasu, T.; Wakabayashi, S.; Jinn, H.; Takahara, M.; Kakita, K.
2018-01-01
We have studied the ultrafast magnon dynamics in an antiferromagnetic 3d-transition-metal monoxide, nickel oxide (NiO), using optical pump-probe spectroscopy and terahertz time-domain spectroscopy (THz-TDS). THz damped magnon oscillations were observed in the Faraday rotation signal and in the transmitted THz electric field via optical pump-probe spectroscopy and THz-TDS, respectively. The magnon signals were observed in both the optical pump-probe spectroscopy and THz-TDS experiments, which shows that both Raman- and infrared-active modes are included in the NiO magnon modes. The magnon relaxation rate observed using THz-TDS was found to be almost constant up to the Néel temperature T N (= 523 K) and to increase abruptly near that temperature. This shows that temperature-independent spin-spin relaxation dominates up to T N . In our experiment, softening of the magnon frequency near T N was clearly observed. This result shows that the optical pump-probe spectroscopy and THz-TDS have high frequency resolution and a high signal to noise ratio in the THz region. We discuss the observed temperature dependence of the magnon frequencies using three different molecular field theories. The experimental results suggest that the biquadratic contribution of the exchange interaction plays an important role in the temperature dependence of the sublattice magnetization and the magnon frequency in cubic antiferromagnetic oxides.
NASA Technical Reports Server (NTRS)
Ealker, David H.; Deming, Glenn
1991-01-01
Heat pump collects heat from water circulating in heat-rejection loop, raises temperature of collected heat, and transfers collected heat to water in separate pipe. Includes sealed motor/compressor with cooling coils, evaporator, and condenser, all mounted in outer housing. Gradients of temperature in evaporator and condenser increase heat-transfer efficiency of vapor-compression cycle. Intended to recover relatively-low-temperature waste heat and use it to make hot water.
Clinical status of comorbid bipolar disorder and borderline personality disorder.
Parker, Gordon; Bayes, Adam; McClure, Georgia; Del Moral, Yolanda Romàn Ruiz; Stevenson, Janine
2016-09-01
The status and differentiation of comorbid borderline personality disorder and bipolar disorder is worthy of clarification. To determine whether comorbid borderline personality disorder and bipolar disorder are interdependent or independent conditions. We interviewed patients diagnosed with either a borderline personality disorder and/or a bipolar condition. Analyses of participants grouped by DSM diagnoses established that those with comorbid conditions scored similarly to those with a borderline personality disorder alone on all key variables (i.e. gender, severity of borderline personality scores, developmental stressors, illness correlates, self-injurious behaviour rates) and differed from those with a bipolar disorder alone on nearly all non-bipolar item variables. Similar findings were returned for groups defined by clinical diagnoses. Comorbid bipolar disorder and borderline personality disorder is consistent with the formal definition of comorbidity in that, while coterminous, individuals meeting such criteria have features of two independent conditions. © The Royal College of Psychiatrists 2016.
Polarization characteristic of a room-temperature Co:MgF2 laser.
Zhang, Zengming M; Cui, Yiben B; Li, Fuli L; Zhang, Guobin B; Pu, Qirong R; Xu, Gaojie J
2002-02-20
A study of the polarization characteristic of a Co:MgF2 laser with a 1320-nm YAG pumping laser at room temperature is reported. The thresholds, output energies, and efficiencies of the laser are given at the various polarization states. The more intensive emission is in the pi-polarization pump laser and sigma-polarization laser operation. Performances of the Co:MgF2 lasers are similar for the polarized and unpolarized laser pumping along the optical axis of the crystal.
ERIC Educational Resources Information Center
Elzy, Meredith B.
2011-01-01
The relationship between childhood sexual abuse and borderline personality disorder is a prominent issue in the etiological research on borderline personality disorder. This study further explored the relationship between childhood sexual abuse and the development of borderline personality features while evaluating the moderating role of a primary…
ERIC Educational Resources Information Center
Clarke, Stephanie B.; Rizvi, Shireen L.; Resick, Patricia A.
2008-01-01
Many studies report that comorbid borderline personality pathology is associated with poorer outcomes in the treatment of Axis I disorders. Given the high rates of comorbidity between borderline personality pathology and posttraumatic stress disorder (PTSD), it is essential to determine whether borderline symptomatology affects PTSD treatment…
Atlas, J A
1995-12-01
Records of 38 hospitalized female adolescents were analyzed to evaluate the relationship between a history of earlier physical and/or sexual abuse and borderline personality. Those with histories of abuse were significantly more likely to score as Borderline Personality Disorder when assessed by the Diagnostic Interview for Borderlines--Revised.
Radiance limits of ceramic phosphors under high excitation fluxes
NASA Astrophysics Data System (ADS)
Lenef, Alan; Kelso, John; Zheng, Yi; Tchoul, Maxim
2013-09-01
Ceramic phosphors, excited by high radiance pump sources, offer considerable potential for high radiance conversion. Interestingly, thermodynamic arguments suggest that the radiance of the luminescent spot can even exceed that of the incoming light source. In practice, however, thermal quenching and (non-thermal) optical saturation limit the maximum attainable radiance of the luminescent source. We present experimental data for Ce:YAG and Ce:GdYAG ceramics in which these limits have been investigated. High excitation fluxes are achieved using laser pumping. Optical pumping intensities exceeding 100W/mm2 have been shown to produce only modest efficiency depreciation at low overall pump powers because of the short Ce3+ lifetime, although additional limitations exist. When pump powers are higher, heat-transfer bottlenecks within the ceramic and heat-sink interfaces limit maximum pump intensities. We find that surface temperatures of these laser-pumped ceramics can reach well over 150°C, causing thermal-quenching losses. We also find that in some cases, the loss of quantum efficiency with increasing temperature can cause a thermal run-away effect, resulting in a rapid loss in converted light, possibly over-heating the sample or surrounding structures. While one can still obtain radiances on the order of many W/mm2/sr, temperature quenching effects ultimately limit converted light radiance. Finally, we use the diffusion-approximation radiation transport models and rate equation models to simulate some of these nonlinear optical pumping and heating effects in high-scattering ceramics.
Facial emotion recognition and borderline personality pathology.
Meehan, Kevin B; De Panfilis, Chiara; Cain, Nicole M; Antonucci, Camilla; Soliani, Antonio; Clarkin, John F; Sambataro, Fabio
2017-09-01
The impact of borderline personality pathology on facial emotion recognition has been in dispute; with impaired, comparable, and enhanced accuracy found in high borderline personality groups. Discrepancies are likely driven by variations in facial emotion recognition tasks across studies (stimuli type/intensity) and heterogeneity in borderline personality pathology. This study evaluates facial emotion recognition for neutral and negative emotions (fear/sadness/disgust/anger) presented at varying intensities. Effortful control was evaluated as a moderator of facial emotion recognition in borderline personality. Non-clinical multicultural undergraduates (n = 132) completed a morphed facial emotion recognition task of neutral and negative emotional expressions across different intensities (100% Neutral; 25%/50%/75% Emotion) and self-reported borderline personality features and effortful control. Greater borderline personality features related to decreased accuracy in detecting neutral faces, but increased accuracy in detecting negative emotion faces, particularly at low-intensity thresholds. This pattern was moderated by effortful control; for individuals with low but not high effortful control, greater borderline personality features related to misattributions of emotion to neutral expressions, and enhanced detection of low-intensity emotional expressions. Individuals with high borderline personality features may therefore exhibit a bias toward detecting negative emotions that are not or barely present; however, good self-regulatory skills may protect against this potential social-cognitive vulnerability. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Keng, Shian-Ling; Wong, Yun Yi
2017-01-01
Linehan's biosocial theory posits that parental invalidation during childhood plays a role in the development of borderline personality disorder symptoms later in life. However, little research has examined components of the biosocial model in an Asian context, and variables that may influence the relationship between childhood invalidation and borderline symptoms. Self-compassion is increasingly regarded as an adaptive way to regulate one's emotions and to relate to oneself, and may serve to moderate the association between invalidation and borderline symptoms. The present study investigated the association among childhood invalidation, self-compassion, and borderline personality disorder symptoms in a sample of Singaporean undergraduate students. Two hundred and ninety undergraduate students from a large Singaporean university were recruited and completed measures assessing childhood invalidation, self-compassion, and borderline personality disorder symptoms. Analyses using multiple regression indicated that both childhood invalidation and self-compassion significantly predicted borderline personality disorder symptomatology. Results from moderation analyses indicated that relationship between childhood invalidation and borderline personality disorder symptomatology did not vary as a function of self-compassion. This study provides evidence in support of aspects of the biosocial model in an Asian context, and demonstrates a strong association between self-compassion and borderline personality disorder symptoms, independent of one's history of parental invalidation during childhood.
Women's Views on Their Diagnosis and Management for Borderline Gestational Diabetes Mellitus
Han, Shanshan; Middleton, Philippa F.; Bubner, Tanya K.; Crowther, Caroline A.
2015-01-01
Introduction. Little is known about women's views relating to a diagnosis of borderline gestational diabetes mellitus (GDM) and the subsequent management. This study aimed to explore women's experiences after being diagnosed with borderline GDM, their attitudes about treatment, and factors important to them for achieving any lifestyle changes. Methods. We conducted face-to-face, semistructured interviews with women diagnosed with borderline GDM. Results. A total of 22 women were interviewed. After a diagnosis of borderline GDM, 14 (64%) women reported not being concerned or worried. Management of borderline GDM was thought by 21 (95%) women to be very important or important. Eighteen (82%) women planned to improve their diet and/or exercise to manage their borderline GDM. The most frequently mentioned enabler for achieving intended lifestyle change was being more motivated to improve the health of their baby and/or themselves (15 women). The most frequent barrier was tiredness and/or being physically unwell (11 women). Conclusions. A diagnosis of borderline GDM caused some concern to one-third of women interviewed. The majority of women believed managing their borderline GDM was important and they planned to improve their lifestyle. Women's own and their babies' future health were powerful motivators for lifestyle change. PMID:25785278
Rego, Karen; Pereira, Kristen; MacDougall, James; Cruikshank, William
2018-01-01
Accurate identification of individuals with TB infection, is required to achieve the WHO's End TB Strategy goals. While there is general acceptance that the T-SPOT.TB test borderline category provides an opportunity to increase test resolution of results around the test cut-off point, this has not been investigated. 645,947 tests were analyzed to determine frequency of borderline results, effect of age and time between tests and associations between subjects' clinical risk factors and retest results. 645,947 tests produced 93.5% negatives, 4% positives, 0.6% invalids, and 1.8% borderlines. Within the borderline results, 5044 were repeated, with 59.2%, 20.0% and 20.2% resolving to negative, positive and borderline, respectively. Age of subject did not affect retest results; however, time between tests indicated that retest resolution occurred with greatest frequency after 90 days. TB risk factors were provided for 2640 subjects and 17% of low risk subjects with a high initial borderline resolved to negative while 27.6% of subjects with high risk and an initial low borderline resolved to positive, suggesting that these subjects could have been inappropriately classified if using a single cut-off point test with no borderline category. This study demonstrates the utility of the T-SPOT.TB test's borderline category to increase test resolution around the test cut-off point. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
DNA Cytometry and Nuclear Morphometry in Ovarian Benign, Borderline and Malignant Tumors
el Din, Amina A. Gamal; Badawi, Manal A.; Aal, Shereen E. Abdel; Ibrahim, Nihad A.; Morsy, Fatma A.; Shaffie, Nermeen M.
2015-01-01
BACKDROUND: Ovarian carcinoma is a leading cause of death in gynecological malignancy. Ovarian surface epithelial serous and mucinous tumours are classified as benign, borderline, and malignant. The identification of borderline tumours most likely to act aggressively remains an important clinical issue. AIM: This work aimed to study DNA ploidy and nuclear area in ovarian serous and mucinous; benign, borderline and malignant tumours. MATERIAL AND METHODS: This study included forty ovarian (23 serous and 17 mucinous) tumours. Paraffin blocks were sectioned; stained with haematoxylin and eosin for histopathologic and morphometric studies and with blue feulgen for DNA analysis. RESULTS: All four serous and six out of nine mucinous benign tumours were diploid. All eight serous and five mucinous malignant tumours were aneuploid. Nine of eleven (81.8%) serous and all three mucinous borderline tumours were aneuploid. There were highly significant differences in mean aneuploid cells percentage between serous benign (1.5%), borderline (45.6%) and malignant (74.5%) (p = 0.0001) and between mucinous benign (13.2%) and both borderline (63.7%) and malignant (68.4%) groups (p = 0.0001). There were significant differences in nuclear area between serous benign (26.191%), borderline (45.619%) and malignant (67.634 %) and a significant positive correlation between mean percentage aneuploid value and mean nuclear area in all serous and mucinous groups. CONCLUSION: We suggest that DNA ploidy and nuclear area combined, may be adjuncts to histopathology; in ovarian serous and mucinous benign, borderline and malignant neoplasms; identifying the aggressive borderline tumours. PMID:27275284
Chabrol, Henri; Raynal, Patrick
2018-04-01
The co-occurrence of Autism Spectrum Disorder (ASD) and Borderline Personality Disorder (BPD) is not rare and has been linked to increased suicidality. Despite this significant comorbidity between ASD and BPD, no study had examined the co-occurrence of autistic traits and borderline personality disorder traits in the general population. The aim of the present study was to examine the co-occurrence of autistic and borderline traits in a non-clinical sample of young adults and its influence on the levels of suicidal ideation and depressive symptomatology. Participants were 474 college students who completed self-report questionnaires. Data were analysed using correlation and cluster analyses. Borderline personality traits and autistic traits were weakly correlated. However, cluster analysis yielded four groups: a low traits group, a borderline traits group, an autistic traits group, and a group characterized by high levels of both traits. Cluster analysis revealed that autistic and borderline traits can co-occur in a significant proportion of young adults. The high autistic and borderline traits group constituted 17% of the total sample and had higher level of suicidal ideation than the borderline traits group, despite similar levels of depressive symptoms. This result suggests that the higher suicidality observed in patients with comorbid ASD and BPD may extent to non-clinical individuals with high levels of co-occurrent autistic and borderline traits. Copyright © 2018 Elsevier Inc. All rights reserved.
DNA Cytometry and Nuclear Morphometry in Ovarian Benign, Borderline and Malignant Tumors.
El Din, Amina A Gamal; Badawi, Manal A; Aal, Shereen E Abdel; Ibrahim, Nihad A; Morsy, Fatma A; Shaffie, Nermeen M
2015-12-15
Ovarian carcinoma is a leading cause of death in gynecological malignancy. Ovarian surface epithelial serous and mucinous tumours are classified as benign, borderline, and malignant. The identification of borderline tumours most likely to act aggressively remains an important clinical issue. This work aimed to study DNA ploidy and nuclear area in ovarian serous and mucinous; benign, borderline and malignant tumours. This study included forty ovarian (23 serous and 17 mucinous) tumours. Paraffin blocks were sectioned; stained with haematoxylin and eosin for histopathologic and morphometric studies and with blue feulgen for DNA analysis. All four serous and six out of nine mucinous benign tumours were diploid. All eight serous and five mucinous malignant tumours were aneuploid. Nine of eleven (81.8%) serous and all three mucinous borderline tumours were aneuploid. There were highly significant differences in mean aneuploid cells percentage between serous benign (1.5%), borderline (45.6%) and malignant (74.5%) (p = 0.0001) and between mucinous benign (13.2%) and both borderline (63.7%) and malignant (68.4%) groups (p = 0.0001). There were significant differences in nuclear area between serous benign (26.191%), borderline (45.619%) and malignant (67.634 %) and a significant positive correlation between mean percentage aneuploid value and mean nuclear area in all serous and mucinous groups. We suggest that DNA ploidy and nuclear area combined, may be adjuncts to histopathology; in ovarian serous and mucinous benign, borderline and malignant neoplasms; identifying the aggressive borderline tumours.
Borderline Personality in the Medical Setting
Sansone, Lori A.
2015-01-01
Objective: Individuals with borderline personality disorder in mental health settings tend to present with relationship difficulties, mood instability/dysphoria, and overt self-harm behavior. In contrast, it appears that individuals with borderline personality disorder in medical settings manifest physical symptoms that are medically difficult to substantiate. Through a review of the literature, we examine 2 symptom manifestations among patients with borderline personality in primary care and general medical settings—namely pain sensitivity and multiple somatic complaints. In addition to reviewing the research of others, we also highlight our own investigations into these 2 areas. Data Sources: We conducted a literature search of the PubMed database and a previous version of the PsycINFO search engine (no restrictions). Search terms included borderline personality, borderline personality disorder, personality disorders; chronic pain, pain, pain syndromes; and somatization disorder, Briquet’s syndrome, somatic preoccupation, somatic. Study Selection: Published articles related to borderline personality, pain and somatic symptoms (ie, somatization disorder, somatic preoccupation) were examined. Results: According to our review, the literature indicates higher-than-expected rates of borderline personality disorder among patients in primary care and general medical settings who present with chronic pain conditions and/or somatic preoccupation. Conclusions: Unlike patients with borderline personality disorder in mental health settings, who tend to present with relationship difficulties, mood instability/dysphoria, and overt self-harm behavior, patients with borderline personality disorder in primary care settings tend to present with unsubstantiated chronic pain of various types as well as somatic preoccupation. PMID:26644960
Prediction of pump cavitation performance
NASA Technical Reports Server (NTRS)
Moore, R. D.
1974-01-01
A method for predicting pump cavitation performance with various liquids, liquid temperatures, and rotative speeds is presented. Use of the method requires that two sets of test data be available for the pump of interest. Good agreement between predicted and experimental results of cavitation performance was obtained for several pumps operated in liquids which exhibit a wide range of properties. Two cavitation parameters which qualitatively evaluate pump cavitation performance are also presented.
Affective Disorders among Patients with Borderline Personality Disorder
Sjåstad, Hege Nordem; Gråwe, Rolf W.; Egeland, Jens
2012-01-01
Background The high co-occurrence between borderline personality disorder and affective disorders has led many to believe that borderline personality disorder should be considered as part of an affective spectrum. The aim of the present study was to examine whether the prevalence of affective disorders are higher for patients with borderline personality disorder than for patients with other personality disorders. Methods In a national cross-sectional study of patients receiving mental health treatment in Norway (N = 36 773), we determined whether psychiatric outpatients with borderline personality disorder (N = 1 043) had a higher prevalence of affective disorder in general, and whether they had an increased prevalence of depression, bipolar disorder or dysthymia specifically. They were compared to patients with paranoid, schizoid, dissocial, histrionic, obsessive-compulsive, avoidant, dependent, or unspecified personality disorder, as well as an aggregated group of patients with personality disorders other than the borderline type (N = 2 636). Odds ratios were computed for the borderline personality disorder group comparing it to the mixed sample of other personality disorders. Diagnostic assessments were conducted in routine clinical practice. Results More subjects with borderline personality disorder suffered from unipolar than bipolar disorders. Nevertheless, borderline personality disorder had a lower rate of depression and dysthymia than several other personality disorder groups, whereas the rate of bipolar disorder tended to be higher. Odds ratios showed 34% lower risk for unipolar depression, 70% lower risk for dysthymia and 66% higher risk for bipolar disorder in patients with borderline personality disorder compared to the aggregated group of other personality disorders. Conclusions The results suggest that borderline personality disorder has a stronger association with affective disorders in the bipolar spectrum than disorders in the unipolar spectrum. This association may reflect an etiological relationship or diagnostic overlapping criteria. PMID:23236411
Missed diagnosis: The emerging crisis of borderline personality disorder in older people.
Beatson, Josephine; Broadbear, Jillian Helen; Sivakumaran, Hemalatha; George, Kuruvilla; Kotler, Eli; Moss, Francine; Rao, Sathya
2016-12-01
Clinical experience suggests a growing prevalence of borderline personality disorder in aged residential care and psychiatric facilities with attendant difficulties in their management. This paper reviews the literature concerning the prevalence, phenomenology and diagnosis of borderline personality disorder in old age. The aim is to elucidate the phenomenological differences in old age and thus improve identification of the disorder. A systematic search was conducted using MEDLINE, PubMed, EMBASE and PsycINFO databases, employing the search terms including 'personality disorder', 'borderline personality disorder', 'aged care', 'gerontology', 'geriatric psychiatry' and 'life span'. The search included articles in English involving participants 65+ years. Long-term prospective studies of borderline personality disorder, long-term follow-up studies and studies involving older adults from 50+ years were also examined. There is a paucity of literature on borderline personality disorder in the elderly. No diagnostic or rating instruments have been developed for borderline personality disorder in the elderly. The phenomenology of borderline personality disorder in the aged population differs in several respects from that seen in younger adults, causing some of the difficulties in reaching a diagnosis. Escalations of symptoms and maladaptive behaviours usually occur when the diagnosis of borderline personality disorder is either not made or delayed. Improved identification of borderline personality disorder in older patients, together with staff education concerning the phenomenology, aetiology and management of these patients, is urgently needed. Diagnostic instruments for borderline personality disorder in the elderly need to be developed. In the interim, suggestions are offered concerning patient symptoms and behaviours that could trigger psychiatric assessment and advice concerning management. A screening tool is proposed to assist in the timely diagnosis of borderline personality disorder in older people. Timely identification of these patients is needed so that they can receive the skilled help, understanding and treatment needed to alleviate suffering in the twilight of their lives. © The Royal Australian and New Zealand College of Psychiatrists 2016.
46 CFR 36.10-1 - Cargo pump relief valves-TB/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo pump relief valves-TB/ALL. 36.10-1 Section 36.10-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS ELEVATED TEMPERATURE CARGOES Piping, Valves, Fittings, and Accessory Equipment § 36.10-1 Cargo pump relief valves—TB/ALL. (a) Cargo pump...
Impact of hyperthermal rotary blood pump surfaces on blood clotting behavior: an approach.
Hamilton, Kathrin F; Schlanstein, Peter C; Mager, Ilona; Schmitz-Rode, Thomas; Steinseifer, Ulrich
2009-09-01
The influence of heat dissipating systems, such as rotary blood pumps, was investigated. Titanium cylinders as rotary blood pump housing dummies were immersed in porcine blood and constantly tempered at specific temperatures (37-60 degrees C) over a defined period of time. The porcine blood was anticoagulated either by low heparin dosage or citrate. At frequent intervals, samples were taken for blood analysis and the determination of the plasmatic coagulation cascade. Blood parameters do not alter at surface temperatures below 50 degrees C. Hyperthermia-induced hemolysis could be confirmed. The plasmatic coagulation cascade is terminated at surface temperatures exceeding 55 degrees C. The adhesion of blood constituents on surfaces is temperature and time dependent, and structural changes of adhesions and blood itself were detected.
Enhanced magnetic Purcell effect in room-temperature masers
Breeze, Jonathan; Tan, Ke-Jie; Richards, Benjamin; Sathian, Juna; Oxborrow, Mark; Alford, Neil McN
2015-01-01
Recently, the world’s first room-temperature maser was demonstrated. The maser consisted of a sapphire ring housing a crystal of pentacene-doped p-terphenyl, pumped by a pulsed rhodamine-dye laser. Stimulated emission of microwaves was aided by the high quality factor and small magnetic mode volume of the maser cavity yet the peak optical pumping power was 1.4 kW. Here we report dramatic miniaturization and 2 orders of magnitude reduction in optical pumping power for a room-temperature maser by coupling a strontium titanate resonator with the spin-polarized population inversion provided by triplet states in an optically excited pentacene-doped p-terphenyl crystal. We observe maser emission in a thimble-sized resonator using a xenon flash lamp as an optical pump source with peak optical power of 70 W. This is a significant step towards the goal of continuous maser operation. PMID:25698634
Design and performance of a 4He-evaporator at <1.0 K
NASA Astrophysics Data System (ADS)
Das, N. K.; Pradhan, J.; Naser, Md. Z. A.; Roy, A.; Mandal, B. Ch.; Mallik, C.; Bhandari, R. K.
2012-12-01
A helium evaporator for obtaining 1 K temperature has been built and tested in laboratory. This will function primarily as the precooling stage for the circulating helium isotopic gas mixture. This works on evaporative cooling by way of pumping out the vapour from the top of the pot. A precision needle valve is used initially to fill up the pot and subsequently a permanent flow impedance maintains the helium flow from the bath into the pot to replenish the evaporative loss of helium. Considering the cooling power of 10 mW @1.0 K, a 99.0 cm3 helium evaporator was designed, fabricated from OFE copper and tested in the laboratory. A pumping station comprising of a roots pump backed by a dry pump was used for evacuation. The calibrated RuO thermometer and kapton film heater were used for measuring the temperature and cooling power of the system respectively. The continuously filled 1 K bath is tested in the laboratory and found to offer a temperature less than 1.0 K by withdrawing vapour from the evaporator. In order to minimize the heat load and to prevent film creep across the pumping tube, size optimization of the pumping line and pump-out port has been performed. The results of test run along with relevant analysis, mechanical fabrication of flow impedance are presented here.
Characterizing somatization, hypochondriasis, and hysteria in the borderline personality disorder.
Snyder, S; Pitts, W M
1986-03-01
Somatization, hypochondriasis, and hysteria have often been considered as associated features of the borderline personality disorder. This study was designed to characterize these three syndromes in the borderline patient. Inpatients with DSM-III borderline personality disorder were compared with controls with dysthymic disorder. Scales and items from standardized rating instruments which measured the three syndromes were scored and compared between groups. Although the hysteria-obvious and hypochondriasis scales of the MMPI and the Hamilton Depression Scale item measuring hypochondriasis were elevated in the borderline group, there were no significant differences between groups. Scores of dysthymic patients significantly exceeded those of borderline patients on four of five MMPI codetypes measuring the three syndromes. Findings are discussed in light of previous psychodynamic, empirical, and research literature.
Prototype of Self-Sensing Magnetic Bearing for Liquid Nitrogen Pump
NASA Astrophysics Data System (ADS)
Eguchi, Seiji; Komori, Mochimitsu; Okuhata, Taro
Recently, pumps used in extremely low temperature such as 77K are found to be necessary. They are expected to use for rocket engines and hydrogen stations for fueled vehicles. Generally, conventional magnetic bearings do not work in the extremely low temperature. Therefore, we have studied magnitic bearings for these pumps. Self-sensing technique is tried to apply to magnetic bearings. If self-sensing magnetic bearings were made, we could apply the self-sensing magnetic bearing to liquid nitrogen pumps. In this paper, we propose a prototype self-sensing magnetic bearing and study the static and dynamic characteristics. The dynamic characteristics in the air and in liquid nitrogen are also discussed.
Heat pump evaluation for Space Station ATCS evolution
NASA Technical Reports Server (NTRS)
Ames, Brian E.; Petete, Patricia A.
1991-01-01
A preliminary feasibility assessment of the application of a vapor compression heat pump to the Active Thermal Control System (ATCS) of SSF is presented. This paper focuses on the methodology of raising the surface temperature of the radiators for improved heat rejection. Some of the effects of the vapor compression cycle on SSF examined include heat pump integration into ATCS, constraints on the heat pump operating parameters, and heat pump performance enhancements.
Rasmussen, Christina B; Jensen, Allan; Albieri, Vanna; Andersen, Klaus K; Kjaer, Susanne K
2016-11-01
Some studies suggest that pelvic inflammatory disease (PID) is a potential risk factor for ovarian cancer. However, only few studies have investigated the association between PID and risk of borderline ovarian tumors. We conducted a population-based cohort study to investigate the association between PID and risk of borderline ovarian tumors. Using various nationwide Danish registries we identified all women in Denmark during 1978-2012, who were born during 1940-1970 (n=1,318,925). Of these, 81,263 women were diagnosed with PID in the study period, and 2736 women had a borderline ovarian tumor (1290 serous and 1344 mucinous). Hazard ratios (HRs) and 95% confidence intervals (CIs) for the association between PID and risk of borderline tumors were estimated using Cox regression models with adjustment for potential confounders. A history of PID was associated with an increased risk of borderline ovarian tumors (HR=1.39; 95% CI: 1.19-1.61). However, histotype-specific analyses revealed significant variation in risk as PID was only associated with an increased risk of serous borderline tumors (HR=1.85; 95% CI: 1.52-2.24), but not with mucinous borderline tumors (HR=1.06; 95% CI: 0.83-1.35). PID is associated with an increased risk of serous borderline tumors. Further research on the potential underlying biological mechanisms and on the identification of the subset of women with PID who are at increased risk of serous borderline tumors is warranted. Copyright © 2016 Elsevier Inc. All rights reserved.
Koenigsberg, Harold W.; Denny, Bryan T.; Fan, Jin; Liu, Xun; Guerreri, Stephanie; Jo Mayson, Sarah; Rimsky, Liza; New, Antonia S.; Goodman, Marianne; Siever, Larry J
2013-01-01
Objective Extreme emotional reactivity is a defining feature of borderline personality disorder, yet the neural-behavioral mechanisms underlying this affective instability are poorly understood. One possible contributor would be diminished ability to engage the mechanism of emotional habituation. We tested this hypothesis by examining behavioral and neural correlates of habituation in borderline patients, healthy controls, and a psychopathological control group of avoidant personality disorder patients. Method During fMRI scan acquisition, borderline patients, healthy controls and avoidant personality disorder patients viewed novel and repeated pictures, providing valence ratings at each presentation. Statistical parametric maps of the contrasts of activation during repeat versus novel negative picture viewing were compared between groups. Psychophysiological interaction analysis was employed to examine functional connectivity differences between groups. Results Unlike healthy controls, neither borderline nor avoidant personality disorder participants showed increased activity in dorsal anterior cingulate cortex when viewing repeat versus novel pictures. This failure to increase dorsal anterior cingulate activity was associated with greater affective instability in borderline participants. In addition, borderline and avoidant participants showed smaller insula-amygdala connectivity increases than healthy participants and did not show habituation in ratings of the emotional intensity of the images as did healthy participants. Borderline patients differed from avoidant patients in insula-ventral anterior cingulate connectivity during habituation. Conclusions Borderline patients fail to habituate to negative pictures as do healthy participants and differ from both healthy controls and avoidant patients in neural activity during habituation. A failure to effectively engage emotional habituation processes may contribute to affective instability in borderline patients. PMID:24275960
Canaz, Emel; Kilinc, Metin; Sayar, Hamide; Kiran, Gurkan; Ozyurek, Eser
2017-09-01
Wide variation exists in ovarian cancer incidence rates suggesting the importance of environmental factors. Due to increasing environmental pollution, trace elements and heavy metals have drawn attention in studies defining the etiology of cancer, but scant data is available for ovarian cancer. Our aim was to compare the tissue concentrations of lead, selenium and nickel in epithelial ovarian cancer, borderline tumor and healthy ovarian tissues. The levels of lead, selenium and nickel were estimated using atomic absorption spectrophotometry in formalin-fixed paraffin-embedded tissue samples. Tests were carried out in 20 malignant epithelial ovarian cancer, 15 epithelial borderline tumor and 20 non-neoplastic healthy ovaries. Two samples were collected for borderline tumors, one from papillary projection and one from the smooth surface of cyst wall. Pb and Ni concentrations were found to be higher both in malignant and borderline tissues than those in healthy ovaries. Concentrations of Pb and Ni in malignant tissues, borderline papillary projections and capsular tissue samples were not different. Comparison of Se concentrations of malignant, borderline and healthy ovarian tissues did not reveal statistical difference. Studied metal levels were not found to be different in either papillary projection or in cyst wall of the borderline tumors. This study revealed the accumulation of lead and nickel in ovarian tissue is associated with borderline and malignant proliferation of the surface epithelium. Accumulation of these metals in epithelial ovarian cancer and borderline ovarian tumor has not been demonstrated before. Copyright © 2017 Elsevier GmbH. All rights reserved.
Problematizing the concept of the "borderline" group in performance assessments.
Homer, Matt; Pell, Godfrey; Fuller, Richard
2017-05-01
Many standard setting procedures focus on the performance of the "borderline" group, defined through expert judgments by assessors. In performance assessments such as Objective Structured Clinical Examinations (OSCEs), these judgments usually apply at the station level. Using largely descriptive approaches, we analyze the assessment profile of OSCE candidates at the end of a five year undergraduate medical degree program to investigate the consistency of the borderline group across stations. We look specifically at those candidates who are borderline in individual stations, and in the overall assessment. While the borderline group can be clearly defined at the individual station level, our key finding is that the membership of this group varies considerably across stations. These findings pose challenges for some standard setting methods, particularly the borderline group and objective borderline methods. They also suggest that institutions should ensure appropriate conjunctive rules to limit compensation in performance between stations to maximize "diagnostic accuracy". In addition, this work highlights a key benefit of sequential testing formats in OSCEs. In comparison with a traditional, single-test format, sequential models allow assessment of "borderline" candidates across a wider range of content areas with concomitant improvements in pass/fail decision-making.
Maternal empathy, family chaos, and the etiology of borderline personality disorder.
Golomb, A; Ludolph, P; Westen, D; Block, M J; Maurer, P; Wiss, F C
1994-01-01
Psychoanalytic writers have traced the etiology of borderline personality disorder (BPD) to be a preoedipal disturbance in the mother-child relationship. Despite the prevalence of theories focusing on the role of mothering in the development of BPD, few empirical studies have tested the hypothesis that borderlines were the recipients of unempathic mothering. The current preliminary study compared 13 mothers of borderline adolescents with 13 mothers of normal adolescents. This study found that mothers of borderlines tended to conceive of their children egocentrically, as need-gratifying objects, rather than as individuals with distinct and evolving personalities. This study also found that the mothers of borderlines reported raising their daughters in extremely chaotic families struggling to cope with multiple hardships, including divorce and financial worries. The stressful environmental circumstances reported by the mothers likely affected the borderline daughters directly as well as the mothers' ability to parent effectively and empathically. The results of this study suggest that, as predicted by psychoanalytic theory, a problematic mother-child relationship may play a significant role in the genesis of borderline pathology; however, the life circumstances that contextualize the mother-child relationship also need to be considered when accounting for the etiology of BPD.
NASA Technical Reports Server (NTRS)
Goldman, Jeffrey H.; Harvey, A.; Lovell, T.; Walker, David H.
1994-01-01
This report describes the Phase 1 process and analysis used to select a refrigerant and thermodynamic cycle as the basis of a vapor compression heat pump requiring a high temperature lift, then to perform a preliminary design to implement the selected concept, including major component selection. Use of a vapor compression heat pump versus other types was based on prior work performed for the Electric Power Research Institute. A high lift heat pump is needed to enable a thermal control system to remove heat down to 275 K from a habitable volume when the external thermal environment is severe. For example, a long-term lunar base habitat will reject heat from a space radiator to a 325 K environment. The first step in the selection process was to perform an optimization trade study, quantifying the effect of radiator operating temperature and heat pump efficiency on total system mass; then, select the radiator operating temperature corresponding to the lowest system mass. Total system mass included radiators, all heat pump components, and the power supply system. The study showed that lunar night operation, with no temperature lift, dictated the radiator size. To operate otherwise would require a high mass penalty to store power. With the defined radiation surface, and heat pump performances assumed to be from 40 percent to 60 percent of the Carnot ideal, the optimum heat rejection temperature ranged from 387 K to 377 K, as a function of heat pump performance. Refrigerant and thermodynamic cycles were then selected to best meet the previously determined design conditions. The system was then adapted as a ground-based prototype lifting temperature to 360 K (versus 385 K for flight unit) and using readily available commercial-grade components. Over 40 refrigerants, separated into wet and dry compression behavioral types, were considered in the selection process. Refrigerants were initially screened for acceptable critical temperature. The acceptable refrigerants were analyzed in ideal single and two-stage thermodynamic cycles. Top candidates were analyzed assuming realistic component limits and system pressure drops, and were evaluated for other considerations such as safety, environmental impact, and commercial availability. A maximum coefficient of performance (COP) of 56 percent of the Carnot ideal was achievable for a three-stage CFC-11 cycle operating under the flight conditions above. The program was completed by defining a control scheme and by researching and selecting the major components, compressor and heat exchangers, that could be used to implement the thermodynamic cycle selected. Special attention was paid to using similar technologies for the SIRF and flight heat pumps resulting in the commercially available equivalent of the flight unit. A package concept was generated for the components selected and mass and volume estimated.
Co-occurrence of dissociative identity disorder and borderline personality disorder.
Ross, Colin A; Ferrell, Lynn; Schroeder, Elizabeth
2014-01-01
The literature indicates that, among individuals with borderline personality disorder, pathological dissociation correlates with a wide range of impairments and difficulties in psychological function. It also predicts a poorer response to dialectical behavior therapy for borderline personality disorder. We hypothesized that (a) dissociative identity disorder commonly co-occurs with borderline personality disorder and vice versa, and (b) individuals who meet criteria for both disorders have more comorbidity and trauma than individuals who meet criteria for only 1 disorder. We interviewed a sample of inpatients in a hospital trauma program using 3 measures of dissociation. The most symptomatic group was those participants who met criteria for both borderline personality disorder and dissociative identity disorder on the Dissociative Disorders Interview Schedule, followed by those who met criteria for dissociative identity disorder only, then those with borderline personality disorder only, and finally those with neither disorder. Greater attention should be paid to the relationship between borderline personality disorder and dissociative identity disorder.
Treatment of borderline personality disorder and co-occurring anxiety disorders
Valenstein, Helen R.
2013-01-01
Anxiety disorders are highly prevalent among individuals with borderline personality disorder, with comorbidity rates of up to 90%. Anxiety disorders have been found to reduce the likelihood of achieving remission from borderline personality disorder over time and to increase the risk of suicide and self-injury in this population. Evidence-based treatments for borderline personality disorder have not sufficiently focused on targeting anxiety disorders, and their effects on these disorders are either limited or unknown. Conversely, evidence-based treatments for anxiety disorders typically exclude suicidal, self-injuring, and seriously comorbid patients, thereby limiting their generalizability to individuals with borderline personality disorder. To address these limitations, recent research has begun to emerge focused on developing and evaluating treatments for individuals with co-occurring borderline personality disorder and anxiety disorders, specifically posttraumatic stress disorder (PTSD), with promising initial results. However, there is a need for additional research in this area, particularly studies evaluating the treatment of anxiety disorders among high-risk and complex borderline personality disorder patients. PMID:23710329
Keuroghlian, Alex S; Palmer, Brian A; Choi-Kain, Lois W; Borba, Christina P C; Links, Paul S; Gunderson, John G
2016-08-01
The effect that attending a 1-day workshop on Good Psychiatric Management (GPM) had on attitudes about borderline personality disorder (BPD) was assessed among 297 clinicians. Change was recorded by comparing before and after scores on a 9-item survey previously developed to assess the effects of workshops on Systems Training for Emotional Predictability and Problem Solving (STEPPS). Participants reported decreased inclination to avoid borderline patients, dislike of borderline patients, and belief that BPD's prognosis is hopeless, as well as increased feeling of competence, belief that borderline patients have low self-esteem, feeling of being able to make a positive difference, and belief that effective psychotherapies exist. Less clinical experience was related to an increased feeling of competence and belief that borderline patients have low self-esteem. These findings were compared to those from the STEPPS workshop. This assessment demonstrates GPM's potential for training clinicians to meet population-wide needs related to borderline personality disorder.
Elzy, Meredith B
2011-05-01
The relationship between childhood sexual abuse and borderline personality disorder is a prominent issue in the etiological research on borderline personality disorder. This study further explored the relationship between childhood sexual abuse and the development of borderline personality features while evaluating the moderating role of a primary social support source in a sample of 290 female undergraduate students enrolled at a major southeastern university. Consistent with previous research, retrospective self-reports of childhood sexual abuse and low social support were both positively correlated with current borderline personality features. It was hypothesized that the presence of a supportive relationship at the time the childhood sexual abuse occurred would moderate the relationship between childhood sexual abuse and borderline personality features. This moderation hypothesis was not supported in the current study, but post-hoc analyses reveal the need to further examine how we define social support following childhood sexual abuse. This research is a stepping stone toward the prevention of borderline personality disorder following childhood sexual abuse.
Keuroghlian, Alex S.; Palmer, Brian A.; Choi-Kain, Lois W.; Borba, Christina P. C.; Links, Paul S.; Gunderson, John G.
2015-01-01
The effect that attending a 1-day workshop on good psychiatric management (GPM) had on attitudes about borderline personality disorder (BPD) was assessed among 297 clinicians. Change was recorded by comparing before and after scores on a 9-item survey previously developed to assess the effects of workshops on Systems Training for Emotional Predictability and Problem Solving (STEPPS). Participants reported decreased inclination to avoid borderline patients, dislike of borderline patients, and belief that BPD’s prognosis is hopeless, as well as increased feeling of competence, belief that borderline patients have low self-esteem, feeling of being able to make a positive difference, and belief that effective psychotherapies exist. Less clinical experience was related to an increased feeling of competence and belief that borderline patients have low self-esteem. These findings were compared to those from the STEPPS workshop. This assessment demonstrates GPM’s potential for training clinicians to meet population-wide needs related to borderline personality disorder. PMID:26111249
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2012 CFR
2012-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2014 CFR
2014-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2013 CFR
2013-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
40 CFR 90.424 - Dilute sampling procedures-CVS calibration.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... Air temperature at CVS pump inlet PTI °C ±1.11 °C. Pressure depression at CVS pump inlet PPI kPa ±0... pump inlet depression that will yield a minimum of six data points for the total calibration. Allow the...: PB = barometric pressure, kPa PPI = Pump inlet depression, kPa. (iii) The correlation function at...
Performance of an Annular Linear Induction Pump with Applications to Space Nuclear Power Systems
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Schoenfeld, Michael; Pearson, J. Boise; Webster, Kenneth; Godfroy, Thomas; Adkins, Harold E., Jr.; Werner, James E.
2010-01-01
Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 125 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head less than 1 to 90 kPa (less than 0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.
Evolution of high-temperature geothermal brine production pumps
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ellis, P.F. II
1989-01-01
Geothermal resources with temperatures between 250{degrees} and 360{degrees}F (121{degrees} and 182{degrees}C) are prime candidates for binary-cycle power generation in the United States and abroad, and constitute about 80% of the known power-capable resources in the United States. Initially there were many technological obstacles to exploitation of these resources, with one of the greatest being the absence of reliable high-capacity downwell brine production pumps to supply the required amounts of brine from an economically small group of wells. Early experience revealed many problems with downwell pumps, resulting in a mean-time-to-failure (MTTF) in 1981 of less than 1000 hours for the bestmore » available technology. This paper reports how evolutionary advances in pump design and materials selection have resolved most of the early problems, producing third- generation pumps which have run as long as 20,000 hours. Pump life extension practices - greatly enhanced component and assembly quality control, increased care in pump installation, and continuous monitoring of pump performance with swift intervention at the first signs of distress - have essentially eliminated premature failure where implemented, leading to estimated near-term MTTFs of 8000 hours.« less
Temperature effects on tunable cw Alexandrite lasers under diode end-pumping.
Kerridge-Johns, William R; Damzen, Michael J
2018-03-19
Diode pumped Alexandrite is a promising route to high power, efficient and inexpensive lasers with a broad (701 nm to 858 nm) gain bandwidth; however, there are challenges with its complex laser dynamics. We present an analytical model applied to experimental red diode end-pumped Alexandrite lasers, which enabled a record 54 % slope efficiency with an output power of 1.2 W. A record lowest lasing wavelength (714 nm) and record tuning range (104 nm) was obtained by optimising the crystal temperature between 8 °C and 105 °C in the vibronic mode. The properties of Alexandrite and the analytical model were examined to understand and give general rules in optimising Alexandrite lasers, along with their fundamental efficiency limits. It was found that the lowest threshold laser wavelength was not necessarily the most efficient, and that higher and lower temperatures were optimal for longer and shorter laser wavelengths, respectively. The pump excited to ground state absorption ratio was measured to decrease from 0.8 to 0.7 by changing the crystal temperature from 10 °C to 90 °C.
Spin-lattice relaxation and the calculation of gain, pump power, and noise temperature in ruby
NASA Technical Reports Server (NTRS)
Lyons, J. R.
1989-01-01
The use of a quantitative analysis of the dominant source of relaxation in ruby spin systems to make predictions of key maser amplifier parameters is described. The spin-lattice Hamiltonian which describes the interaction of the electron spins with the thermal vibrations of the surrounding lattice is obtained from the literature. Taking into account the vibrational anisotropy of ruby, Fermi's rule is used to calculate the spin transition rates between the maser energy levels. The spin population rate equations are solved for the spin transition relaxation times, and a comparison with previous calculations is made. Predictions of ruby gain, inversion ratio, and noise temperature as a function of physical temperature are made for 8.4-GHz and 32-GHz maser pumping schemes. The theory predicts that ruby oriented at 90 deg will have approximately 50 percent higher gain in dB and slightly lower noise temperature than a 54.7-deg ruby at 32 GHz (assuming pump saturation). A specific calculation relating pump power to inversion ratio is given for a single channel of the 32-GHz reflected wave maser.
Borderline personality disorder
... this page: //medlineplus.gov/ency/article/000935.htm Borderline personality disorder To use the sharing features on this page, please enable JavaScript. Borderline personality disorder (BPD) is a mental condition in which ...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Robb, Kevin R.; Jain, Prashant K.; Hazelwood, Thomas J.
Fluoride salt cooled high-temperature reactor (FHR) concepts include pumps for forced circulation of the primary and secondary coolants. As part of a cooperative research and development agreement between the Shanghai Institute of Applied Physics and the Oak Ridge National Laboratory (ORNL), a research project was initiated to aid in the development of pumps for high-temperature salts. The objectives of the task included characterization of the behavior of an existing ORNL LSTL pump; design and test a modified impeller and volute for improved pump characteristics; and finally, provide lessons learned, recommendations, and guidelines for salt pump development and design. The pumpmore » included on the liquid salt test loop (LSTL) at ORNL served as a case study. This report summarizes the progress to date. The report is organized as follows. First, there is a review, focused on pumps, of the significant amount of work on salts at ORNL during the 1950s 1970s. The existing pump on the LSTL is then described. Plans for hot and cold testing of the pump are then discussed, including the design for a cold shakedown test stand and the required LSTL modifications for hot testing. Initial hydraulic and vibration modeling of the LSTL pump is documented. Later, test data from the LSTL will be used to validate the modeling approaches, which could then be used for future pump design efforts. Some initial insights and test data from the pump are then provided. Finally, some preliminary design goals and requirements for a future LSTL pump are provided as examples of salt pump design considerations.« less
Single-frequency tunable laser for pumping cesium frequency standards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhuravleva, O V; Ivanov, Andrei V; Leonovich, A I
2006-08-31
A single-frequency tunable laser for pumping the cesium frequency standard is studied. It is shown experimentally that the laser emits at a single frequency despite the fact that a few longitudinal modes of the external cavity fall within the reflection band of a fibre Bragg grating (FBG) written in the optical fibre. The laser wavelength can be tuned by varying the pump current of the laser, its temperature, and the FBG temperature. The laser linewidth does not exceed 2 MHz for 10 mW of output power. (lasers)
Regenerative adsorbent heat pump
NASA Technical Reports Server (NTRS)
Jones, Jack A. (Inventor)
1991-01-01
A regenerative adsorbent heat pump process and system is provided which can regenerate a high percentage of the sensible heat of the system and at least a portion of the heat of adsorption. A series of at least four compressors containing an adsorbent is provided. A large amount of heat is transferred from compressor to compressor so that heat is regenerated. The process and system are useful for air conditioning rooms, providing room heat in the winter or for hot water heating throughout the year, and, in general, for pumping heat from a lower temperature to a higher temperature.
NASA Astrophysics Data System (ADS)
Kunugi, Yoshifumi; Kashiwagi, Takao
Various advanced absorption cycles are studied, developed and invented. In this paper, their cycles are classified and arranged using the three categories: effect, stage and loop, then an outline of the cycles are explained on the Duehring diagram. Their cycles include high COP cycles for refrigerations and heat pumps, high temperature lift cycles for heat transformer, absorption-compression hybrid cycles and heat pump transformer cycle. The highest COPi is attained by the seven effect cycle. In addition, the cycles for low temperature are invented and explained. Furthermore the power generation • refrigeration cycles are illustrated.
Waste-Heat-Driven Cooling Using Complex Compound Sorbents
NASA Technical Reports Server (NTRS)
Rocketfeller, Uwe; Kirol, Lance; Khalili, Kaveh
2004-01-01
Improved complex-compound sorption pumps are undergoing development for use as prime movers in heat-pump systems for cooling and dehumidification of habitats for humans on the Moon and for residential and commercial cooling on Earth. Among the advantages of sorption heat-pump systems are that they contain no moving parts except for check valves and they can be driven by heat from diverse sources: examples include waste heat from generation of electric power, solar heat, or heat from combustion of natural gas. The use of complex compound sorbents in cooling cycles is not new in itself: Marketing of residential refrigerators using SrCl2 was attempted in the 1920s and 30s and was abandoned because heat- and mass-transfer rates of the sorbents were too low. Addressing the issue that gave rise to the prior abandonment of complex compound sorption heat pumps, the primary accomplishment of the present development program thus far has been the characterization of many candidate sorption media, leading to large increases in achievable heat- and mass-transfer rates. In particular, two complex compounds (called "CC260-1260" and "CC260-2000") were found to be capable of functioning over the temperature range of interest for the lunar-habitat application and to offer heat- and mass-transfer rates and a temperature-lift capability adequate for that application. Regarding the temperature range: A heat pump based on either of these compounds is capable of providing a 95-K lift from a habitable temperature to a heat-rejection (radiator) temperature when driven by waste heat at an input temperature .500 K. Regarding the heat- and mass-transfer rates or, more precisely, the power densities made possible by these rates: Power densities observed in tests were 0.3 kilowatt of cooling per kilogram of sorbent and 2 kilowatts of heating per kilogram of sorbent. A prototype 1-kilowatt heat pump based on CC260-2000 has been built and demonstrated to function successfully.
NASA Technical Reports Server (NTRS)
Davis, Donald Y. (Inventor); Hitch, Bradley D. (Inventor)
1994-01-01
A fluid channeling system includes a fluid ejector, a heat exchanger, and a fluid pump disposed in series flow communication The ejector includes a primary inlet for receiving a primary fluid, and a secondary inlet for receiving a secondary fluid which is mixed with the primary fluid and discharged therefrom as ejector discharge. Heat is removed from the ejector discharge in the heat exchanger, and the heat exchanger discharge is compressed in the fluid pump and channeled to the ejector secondary inlet as the secondary fluid In an exemplary embodiment, the temperature of the primary fluid is greater than the maximum operating temperature of a fluid motor powering the fluid pump using a portion of the ejector discharge, with the secondary fluid being mixed with the primary fluid so that the ejector discharge temperature is equal to about the maximum operating temperature of the fluid motor.
ERIC Educational Resources Information Center
De Moor, Marleen H. M.; Distel, Marijn A.; Trull, Timothy J.; Boomsma, Dorret I.
2009-01-01
Borderline personality disorder (BPD) is more often diagnosed in women than in men, and symptoms tend to decline with age. Using a large community sample, the authors investigated whether sex and age differences in four main features of BPD, measured with the "Personality Assessment Inventory-Borderline Features" scale (PAI-BOR; Morey,…
Abbin, J.P.; Andraka, C.E.; Lukens, L.L.; Moreno, J.B.
1992-01-14
An electrical pump for pumping liquid metals to high pressures in high temperature environments without the use of magnets or moving mechanical parts. The pump employs a non-porous solid electrolyte membrane, typically ceramic, specific to the liquid metal to be pumped. A DC voltage is applied across the thickness of the membrane causing ions to form and enter the membrane on the electrically positive surface, with the ions being neutralized on the opposite surface. This action provides pumping of the liquid metal from one side of the non-porous solid electrolyte membrane to the other. 3 figs.
2013-01-01
after pump calibrations , transfer pump blade measurements, injector nozzle tests, pump parts evaluation, and parts conditions photographs are also... Injectors –0 0.53 5,500 0.257 1 2-15293089 DF2 As Purchased 105 (40) 1,000 1,000 Calibration off spec areas–4 Pump Rating–1.04 Failed Injectors –0 0.53...5,500 0.257 2 1-15382732 DF2 As Purchased 135 (57) 1,000 1,000 Calibration off spec areas–4 Pump Rating–1.13 Failed Injectors –0 0.55
Abbin, Joseph P.; Andraka, Charles E.; Lukens, Laurance L.; Moreno, James B.
1992-01-01
An electrical pump for pumping liquid metals to high pressures in high temperature environments without the use of magnets or moving mechanical parts. The pump employs a non-porous solid electrolyte membrane, typically ceramic, specific to the liquid metal to be pumped. A DC voltage is applied across the thickness of the membrane causing ions to form and enter the membrane on the electrically positive surface, with the ions being neutralized on the opposite surface. This action provides pumping of the liquid metal from one side of the non-porous solid electrolyte membrane to the other.
Practical and efficient magnetic heat pump
NASA Technical Reports Server (NTRS)
Brown, G. V.
1978-01-01
Method for pumping heat magnetically at room temperature is more economical than existing refrigeration systems. Method uses natural magneto-thermal effect of gadolinium metal to establish temperature gradient across length of tube. Regenerative cyclic process in which gadolinium sample is magnetized and gives off heat at one end of tube, and then is demagnetized at other end to absorb heat has established temperature gradients of 144 degrees F in experiments near room temperature. Other materials with large magnetothermal effects can be used below room temperature. Possible commercial applications include freeze-drying and food processing, cold storage, and heating and cooling of buildings, plants, and ships.
Influence of fluid temperature gradient on the flow within the shaft gap of a PLR pump
NASA Astrophysics Data System (ADS)
Qian, W.; Rosic, B.; Zhang, Q.; Khanal, B.
2016-03-01
In nuclear power plants the primary-loop recirculation (PLR) pump circulates the high temperature/high-pressure coolant in order to remove the thermal energy generated within the reactor. The pump is sealed using the cold purge flow in the shaft seal gap between the rotating shaft and stationary casing, where different forms of Taylor-Couette flow instabilities develop. Due to the temperature difference between the hot recirculating water and the cold purge water (of order of 200 °C), the flow instabilities in the gap cause temperature fluctuations, which can lead to shaft or casing thermal fatigue cracks. The present work numerically investigated the influence of temperature difference and rotating speed on the structure and dynamics of the Taylor-Couette flow instabilities. The CFD solver used in this study was extensively validated against the experimental data published in the open literature. Influence of temperature difference on the fluid dynamics of Taylor vortices was investigated in this study. With large temperature difference, the structure of the Taylor vortices is greatly stretched at the interface region between the annulus gap and the lower recirculating cavity. Higher temperature difference and rotating speed induce lower fluctuating frequency and smaller circumferential wave number of Taylor vortices. However, the azimuthal wave speed remains unchanged with all the cases tested. The predicted axial location of the maximum temperature fluctuation on the shaft is in a good agreement with the experimental data, identifying the region potentially affected by the thermal fatigue. The physical understandings of such flow instabilities presented in this paper would be useful for future PLR pump design optimization.
Borderline Personality and Criminality
Sansone, Lori A.
2009-01-01
Borderline personality disorder is characteristically associated with a broad variety of psychiatric symptoms and aberrant behaviors. In this edition of The Interface, we discuss the infrequently examined association between borderline personality disorder and criminality. According to our review of the literature, in comparison with the rates of borderline personality disorder encountered in the general population, borderline personality disorder is over-represented in most studies of inmates. At the same time, there is considerable variation in the reported rates of this Axis II disorder in prison populations, which may be attributed to the methodologies of and populations in the various studies. Overall, female criminals appear to exhibit higher rates of borderline personality disorder, and it is oftentimes associated with a history of childhood sexual abuse, perpetration of impulsive and violent crimes, comorbid antisocial traits, and incarceration for domestic violence. PMID:20011575
Adverse perinatal outcomes in borderline amniotic fluid index.
Jamal, Ashraf; Kazemi, Maryam; Marsoosi, Vajiheh; Eslamian, Laleh
2016-11-01
Normal amniotic fluid predicts normal placental function, fetal growth and fetal well-being. To determine adverse pregnancy outcomes in borderline amniotic fluid index (AFI). Pregnant women (37-40 wks) with diagnosis of borderline AFI between December 2012 and August 2014 were identified. Antepartum, intrapartum and neonatal data were collected and compared with those of pregnant women with normal AFI. An AFI less than 8 and more than 5 cm was defined for borderline AFI. Pregnancy outcomes included Cesarean section for non-reassuring fetal heart rate, meconium stained amniotic fluid, 5-min Apgar score <7, low birth weight, umbilical cord blood pH at term and NICU admission. Gestational age at delivery in pregnancies with borderline AFI was significantly lower than normal AFI. Cesarean section rate for non-reassuring fetal heart rate in women of borderline AFI was significantly higher and there was an increased incidence of birth weight less than 10 th percentile for gestation age in borderline AFI group. Incidence of low Apgar score and low umbilical artery pH in pregnancies with borderline AFI was significantly higher than women with normal AFI. There were no significant difference in the rate of NICU admission and meconium staining in both groups. There are significant differences for adverse pregnancy outcomes , such as Cesarean section due to non-reassuring fetal heart rate, birth weight less than 10 th percentile for gestation age, low 5 min Apgar score and low umbilical artery pH between pregnancies with borderline and normal AFI.
Borderline personality disorder and polycystic ovary syndrome: A review of the literature.
Tan, Raelene Ym; Grigg, Jasmin; Kulkarni, Jayashri
2018-02-01
This review examines the existing evidence for the relationship between borderline personality disorder and polycystic ovary syndrome, and to identify commonalities in etiological mechanisms of borderline personality disorder and polycystic ovary syndrome that might explain the relationship between these seemingly disparate disorders. A search of Medline, EMBASE and Cochrane Central was undertaken on 5 December 2016 to identify studies investigating women with borderline personality disorder and polycystic ovary syndrome (or symptoms and markers specific to polycystic ovary syndrome). Nine studies were identified, including three cross-sectional studies investigating symptoms of polycystic ovary syndrome in women with borderline personality disorder, two cross-sectional and one cohort study examining the prevalence of psychiatric diagnoses in women with polycystic ovary syndrome and three case reports of comorbid borderline personality disorder and polycystic ovary syndrome. Overall, the literature shows women with borderline personality disorder to have higher than expected serum androgen levels and incidence of polycystic ovaries, which can be key features of polycystic ovary syndrome. However, this research is still in its infancy, which limits our understanding of this potential comorbid phenomenon. Given the emerging anecdotal and empirical evidence to date, a theoretical discussion of the potential psychoneuroendocrinological mechanism underlying the borderline personality disorder and polycystic ovary syndrome comorbidity is provided. Further rigorous studies using standardized diagnostic criteria for polycystic ovary syndrome are warranted. Specifically, the use of prospective controlled cohort studies may be able to determine the causality and temporality of observed comorbid borderline personality disorder and polycystic ovary syndrome.
NASA Astrophysics Data System (ADS)
Weike, Pang; Wenju, Lin; Qilin, Pan; Wenye, Lin; Qunte, Dai; Luwei, Yang; Zhentao, Zhang
2014-01-01
In this paper, a set of heat pump (called as Mechanical Vapor Recompression, MVR) propelled by a centrifugal fan is tested and it shows some special characteristic when it works together with a falling film evaporator. Firstly, an analysis of the fan's suction and discharge parameters at stable state, such as its pressure and temperature, indicates that a phenomenon of wet compression is probably to appear during vapor compression. As a result, superheat after saturated vapor is compressed is eliminated, which reduces discharge temperature of the system. It is because drops boil away and absorb the super heat into their latent heat during vapor compression. Meanwhile, drops in the suction vapor add to the compressed vapor, which increase the given heat of the MVR heat pump. Next, assistant electric heat could adjust and keep steady of the operating pressure and temperature of an MVR heat pump. With the evaporation temperature up to be high, heat balance is broken and supplement heat needs to increase. Thirdly, the performance of an MVR heat pump is affect by the balance of falling film and evaporation that has an effect on heat transfer. Then, two parameters standing for the performance are measured as it runs in practical condition. The two important parameters are consumptive electricity power and productive water capacity. According to theoretical work in ideal condition by calculation and fan's input power by measure as running, adiabatic efficiency (ηad) of a centrifugal fan is calculated when it is applied in a heat pump of MVR. Following, based on ηad, practical SMER and COP of an MVR heat pump are discovered to be correlative with it. Finally, in dependence on productive water in theory and in practice, displacement efficiency (ηv) of centrifugal fans is obtained when compressing vapor, and so provide some references of matching a fan for an MVR heat pump. On the other hand, it is helpful to research and develop MVR heat pumps, and also to check electricity power consumption while operating practically in light of electric motor efficiency (ηe) and ηad.
Sievers, Robert K.; Cooper, Martin H.; Tupper, Robert B.
1987-01-01
A self-actuated shutdown system incorporated into a reactivity control assembly in a nuclear reactor includes pumping means for creating an auxiliary downward flow of a portion of the heated coolant exiting from the fuel assemblies disposed adjacent to the control assembly. The shutdown system includes a hollow tubular member which extends through the outlet of the control assembly top nozzle so as to define an outer annular flow channel through the top nozzle outlet separate from an inner flow channel for primary coolant flow through the control assembly. Also, a latching mechanism is disposed in an inner duct of the control assembly and is operable for holding absorber bundles in a raised position in the control assembly and for releasing them to drop them into the core of the reactor for shutdown purposes. The latching mechanism has an inner flow passage extending between and in flow communication with the absorber bundles and the inner flow channel of the top nozzle for accommodating primary coolant flow upwardly through the control assembly. Also, an outer flow passage separate from the inner flow passage extends through the latching mechanism between and in flow communication with the inner duct and the outer flow channel of the top nozzle for accommodating inflow of a portion of the heated coolant from the adjacent fuel assemblies. The latching mechanism contains a magnetic material sensitive to temperature and operable to cause mating or latching together of the components of the latching mechanism when the temperature sensed is below a known temperature and unmating or unlatching thereof when the temperature sensed is above a given temperature. The temperature sensitive magnetic material is positioned in communication with the heated coolant flow through the outer flow passage for directly sensing the temperature thereof. Finally, the pumping means includes a jet induction pump nozzle and diffuser disposed adjacent the bottom nozzle of the control assembly and in flow communication with the inlet thereof. The pump nozzle is operable to create an upward driving flow of primary coolant through the pump diffuser and then to the absorber bundles. The upward driving flow of primary coolant, in turn, creates a suction head within the outer flow channel of the top nozzle and thereby an auxiliary downward flow of the heated coolant portion exiting from the upper end of the adjacent fuel assemblies through the outer flow channel to the pump nozzle via the outer flow passage of the latching mechanism and an annular space between the outer and inner spaced ducts of the control assembly housing. The temperature of the heated coolant exiting from the adjacent fuel assemblies can thereby be sensed directly by the temperature sensitive magnetic material in the latching mechanism.
Solar-powered Rankine heat pump for heating and cooling
NASA Technical Reports Server (NTRS)
Rousseau, J.
1978-01-01
The design, operation and performance of a familyy of solar heating and cooling systems are discussed. The systems feature a reversible heat pump operating with R-11 as the working fluid and using a motor-driven centrifugal compressor. In the cooling mode, solar energy provides the heat source for a Rankine power loop. The system is operational with heat source temperatures ranging from 155 to 220 F; the estimated coefficient of performance is 0.7. In the heating mode, the vapor-cycle heat pump processes solar energy collected at low temperatures (40 to 80 F). The speed of the compressor can be adjusted so that the heat pump capacity matches the load, allowing a seasonal coefficient of performance of about 8 to be attained.
NASA Astrophysics Data System (ADS)
Lang, Ye; Chen, Yanzhong; Liao, Lifen; Guo, Guangyan; He, Jianguo; Fan, Zhongwei
2018-03-01
In high power diode lasers, the input cooling water temperature would affect both output power and output spectrum. In double face pumped slab laser, the spectrum of two laser diode arrays (LDAs) must be optimized for efficiency reason. The spectrum mismatch of two LDAs would result in energy storing decline. In this work, thermal induced efficiency decline due to spectral overlap between high power LDAs and laser medium was investigated. A numerical model was developed to describe the energy storing variation with changing LDAs cooling water temperature and configuration (series/parallel connected). A confirmatory experiment was conducted using a double face pumped slab module. The experiment results show good agreements with simulations.
Frostless heat pump having thermal expansion valves
Chen, Fang C [Knoxville, TN; Mei, Viung C [Oak Ridge, TN
2002-10-22
A heat pump system having an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant and further having a compressor, an interior heat exchanger, an exterior heat exchanger, a heat pump reversing valve, an accumulator, a thermal expansion valve having a remote sensing bulb disposed in heat transferable contact with the refrigerant piping section between said accumulator and said reversing valve, an outdoor temperature sensor, and a first means for heating said remote sensing bulb in response to said outdoor temperature sensor thereby opening said thermal expansion valve to raise suction pressure in order to mitigate defrosting of said exterior heat exchanger wherein said heat pump continues to operate in a heating mode.
The prevalence of borderline personality symptoms in adolescents.
Mohammadi, Mohammad Reza; Shamohammadi, Morteza; Salmanian, Maryam
2014-07-01
This study aimed to assess the prevalence of borderline personality symptoms in 16-18 year old adolescents. In this cross sectional - descriptive study, 422 high school students (211 boys, 211 girls) aged 16-18 were selected by cluster random sampling and simple random sampling in 2011-2012. The participants were assessed using the revised diagnostic interview for borderline questionnaire (DIB-R) and demographic questionnaire. Data were analyzed using Pearson correlation coefficient and Spearman correlation coefficient. Of the participants, 0/9% (0/22 % of the 16 year olds, 0.45 % of the 17 year olds and 0/22% of the 18 year olds) were diagnosed with borderline personality symptoms. Also, the prevalence of borderline personality symptoms in boys was 0/45 % of the total sample and it was 0/45 % of the total sample in girls. With respect to the relationship between demographic variables (age, sex, location, parents' occupation, parents' kinship, parents' education and birth order) and borderline personality symptoms, only parents' kinship showed a weak correlation with borderline personality symptoms. In the view of the prevalence of 0.9% of the borderline personality symptoms in adolescents, attention should be paid to the diagnosis and treatment of this disorder. Furthermore, works need to be done to improve the mental health and quality of life of adolescents.
Zhao, Shanyu; Jiang, Bo; Maeder, Thomas; Muralt, Paul; Kim, Nayoung; Matam, Santhosh Kumar; Jeong, Eunho; Han, Yen-Lin; Koebel, Matthias M
2015-08-26
With growing public interest in portable electronics such as micro fuel cells, micro gas total analysis systems, and portable medical devices, the need for miniaturized air pumps with minimal electrical power consumption is on the rise. Thus, the development and downsizing of next-generation thermal transpiration gas pumps has been investigated intensively during the last decades. Such a system relies on a mesoporous membrane that generates a thermomolecular pressure gradient under the action of an applied temperature bias. However, the development of highly miniaturized active membrane materials with tailored porosity and optimized pumping performance remains a major challenge. Here we report a systematic study on the manufacturing of aerogel membranes using an optimized, minimal-shrinkage sol-gel process, leading to low thermal conductivity and high air conductance. This combination of properties results in superior performance for miniaturized thermomolecular air pump applications. The engineering of such aerogel membranes, which implies pore structure control and chemical surface modification, requires both chemical processing know-how and a detailed understanding of the influence of the material properties on the spatial flow rate density. Optimal pumping performance was found for devices with integrated membranes with a density of 0.062 g cm(-3) and an average pore size of 142.0 nm. Benchmarking of such low-density hydrophobic active aerogel membranes gave an air flow rate density of 3.85 sccm·cm(-2) at an operating temperature of 400 °C. Such a silica aerogel membrane based system has shown more than 50% higher pumping performance when compared to conventional transpiration pump membrane materials as well as the ability to withstand higher operating temperatures (up to 440 °C). This study highlights new perspectives for the development of miniaturized thermal transpiration air pumps while offering insights into the fundamentals of molecular pumping in three-dimensional open-mesoporous materials.
Emotional Hypochondriasis, Hyperbole, and the Borderline Patient
ZANARINI, MARY C.; FRANKENBURG, FRANCES R.
1994-01-01
The authors define a new defense mechanism, emotional hypochondriasis, that is hypothesized to be central to borderline psychopathology. The behavioral manifestation of this defense—the hyperbolic stance of the borderline patient—is also defined and related to the complex phenomenology of borderline personality disorder. Borderline patients are seen as making an active attempt to maintain a tolerable, if tenuous, adaptation in the face of tremendous subjective emotional pain that has been shaped in large measure by traumatic childhood events that have never been validated. Twelve treatment implications and three expectable, if overlapping, stages of treatment stemming from the use of this defense and its behavioral sequelae are detailed. PMID:22700171
Custom Unit Pump Development for the EVA PLSS
NASA Technical Reports Server (NTRS)
Schuller, Michael; Kurwitz, Cable; Little, Frank; Oinuma, Ryoji; Larsen, Ben; Goldman, Jeff; Reinis, Filip; Trevino, Luis
2010-01-01
This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, seal-less, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion, and restart capability under both ambient and vacuum conditions. The pump operated at 40 to 240 lbm/hr flow rate, 35 to 100 oF pump temperature, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test.
NASA Technical Reports Server (NTRS)
Gahan, J. W.; Powell, A. H.; Pileggi, P. T.; Thompson, S. P.
1972-01-01
A three-phase helical induction electromagnetic (EM) pump has been designed and built. This pump was designed for use as the boiler-feed pump of a potassium Rankine-cycle space electric power system. The pump is constructed of high temperature materials including a T-111 duct, Hiperco 27 magnetic material, nickel clad silver conductor wire, and a completely inorganic insulation system. The pump is designed to deliver 3.25 lb/sec potassium at 1000 F with a developed head of 240 psi while being cooled by 800 F NaK. At these conditions, the overall pump efficiency is expected to be 18%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yurkin, A A
2016-03-31
We report the results of experimental studies of a copper vapour laser with a semiconductor pump generator capable of forming virtually optimal pump pulses with a current rise steepness of about 40 A ns{sup -1} in a KULON LT-1.5CU active element. To maintain the operating temperature of the active element's channel, an additional heating pulsed oscillator is used. High efficiency of the pump generator is demonstrated. (lasers)
Lu, Wei-Hsin; Lee, Kun-Hua; Ko, Chih-Hung; Hsiao, Ray C; Hu, Huei-Fan; Yen, Cheng-Fang
2017-09-01
Aim To examine the relationship between borderline personality symptoms and Internet addiction as well as the mediating role of mental health problems between them. Methods A total of 500 college students from Taiwan were recruited and assessed for symptoms of Internet addiction using the Chen Internet Addiction Scale, borderline personality symptoms using the Taiwanese version of the Borderline Symptom List and mental health problems using four subscales from the Symptom Checklist-90-Revised Scale (interpersonal sensitivity, depression, anxiety, and hostility). Structural equation modeling (SEM) was used to test our hypothesis that borderline personality symptoms are associated with the severity of Internet addiction directly and also through the mediation of mental health problems. Results SEM analysis revealed that all paths in the hypothesized model were significant, indicating that borderline personality symptoms were directly related to the severity of Internet addiction as well as indirectly related to the severity of Internet addiction by increasing the severity of mental health problems. Conclusion Borderline personality symptoms and mental health problems should be taken into consideration when designing intervention programs for Internet addiction.
Reitz, Sarah; Kluetsch, Rosemarie; Niedtfeld, Inga; Knorz, Teresa; Lis, Stefanie; Paret, Christian; Kirsch, Peter; Meyer-Lindenberg, Andreas; Treede, Rolf-Detlef; Baumgärtner, Ulf; Bohus, Martin; Schmahl, Christian
2015-08-01
Patients with borderline personality disorder frequently show non-suicidal self-injury (NSSI). In these patients, NSSI often serves to reduce high levels of stress. Investigation of neurobiological mechanisms of NSSI in borderline personality disorder. In total, 21 women with borderline personality disorder and 17 healthy controls underwent a stress induction, followed by either an incision into the forearm or a sham treatment. Afterwards participants underwent resting-state functional magnetic resonance imaging while aversive tension, heart rate and heart rate variability were assessed. We found a significant influence of incision on subjective and objective stress levels with a stronger decrease of aversive tension in the borderline personality disorder group following incision than sham. Amygdala activity decreased more and functional connectivity with superior frontal gyrus normalised after incision in the borderline personality disorder group. Decreased stress levels and amygdala activity after incision support the assumption of an influence of NSSI on emotion regulation in individuals with borderline personality disorder and aids in understanding why these patients use self-inflicted pain to reduce inner tension. © The Royal College of Psychiatrists 2015.
Nelson, Barnaby; Thompson, Andrew; Chanen, Andrew M; Amminger, Günther Paul; Yung, Alison R
2013-08-01
Research in the phenomenological tradition suggests that the schizophrenia spectrum is characterized by disturbance of the 'basic' self, whereas borderline personality disorder involves disturbance of the 'narrative' self. The current study investigated this proposal in an ultra-high risk for psychosis sample. The sample consisted of 42 ultra-high-risk participants with a mean age of 19.22 years. Basic self-disturbance was measured using the Examination of Anomalous Self-Experience. Borderline personality pathology was measured using the borderline personality disorder items from the structured clinical interview for DSM-IV (Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition) Axis II Personality Questionnaire. No correlation was found between the measures of basic self-disturbance and borderline personality pathology. The finding is consistent with the proposal that different (although not mutually exclusive) types of self-disturbance characterize the schizophrenia spectrum and borderline personality disorder. Further research should further examine the question of basic self-disturbance in patients with established borderline personality disorder. © 2013 Wiley Publishing Asia Pty Ltd.
Neurochemical alterations associated with borderline personality disorder.
Atmaca, Murad; Karakoc, Tevfik; Mermi, Osman; Gurkan Gurok, M; Yildirim, Hanefi
2015-01-01
In neuroimaging on borderline personality disorder, prior studies focused on the hippocampus and amygdala, as mentioned above. However, no study investigated whether there were neurochemical changes in the patients with borderline personality disorder. Therefore, in the present study, we aimed to investigate neurochemical change of patients diagnosed with borderline disorder and hypothesized that neurochemicals would change in the hippocampus region of these patients. Seventeen patients and the same number of healthy control subjects were analyzed by using a 1.5 Tesla GE Signa Imaging System. N-acetylaspartate (NAA), choline compounds (CHO), and creatine (CRE) values of hippocampal region were measured. The mean NAA/CRE ratio in the hippocampus region was significantly reduced in the patients with borderline personality disorder compared to that of healthy control subjects, In addition, NAA/CHO ratio of the patients with borderline personality disorder was also significantly reduced when compared to that of healthy subjects. There was no difference in the ratio of CHO/CRE. In summary, we present evidence for reduced NAA in the patients with borderline personality disorder. © 2015, The Author(s).
NASA Technical Reports Server (NTRS)
Lee, J. H.; Shiu, Y. J.; Weaver, W. R.
1980-01-01
The feasibility of direct solar pumping of an iodine photodissociation laser at lambda = 1.315 microns was investigated. Threshold inversion density and effect of elevated temperature (up to 670 K) on the laser output were measured. These results and the concentration of solar radiation required for the solar pumped iodine laser are discussed.
Dual-frequency continuous wave optical parametric oscillator
NASA Astrophysics Data System (ADS)
Sun, Bingjie; Wang, Xin; Yang, Suhui; Li, Kun
2018-01-01
This article shows a dual-frequency OPO with multi-grating (28.5-31.5 μm) periodically poled MgO:LiNbO3 (MgO:PPLN) pumped by a dual-frequency continuous wave at 1.064 μm. The wavelengths of idler and signal varying versus temperature at different periods of inverted domains were numerical simulated. It proves that as the temperature rises, or as the poling period increases, the idler wavelength shortens and signal wavelength lengthens. The pump is a 30 W dual-frequency fiber laser MOPA with beat note frequency varying from 125 MHz to 175 MHz. The pump threshold of the bow-tie ring cavity OPO was 3 W. An average dual-frequency idler output power of 2.6 W was obtained when the pump power was 17.2 W at 45 °C. The idler wavelength was 3.4 μm when the poling period was 30.5 μm. The idler wavelength could be tuned from 2.9 μm to 3.9 μm by changing the temperature and the poling period, and the beat note frequency was proved to be equal to that of the pump.
Merza, Katalin; Harmatta, János; Papp, Gábor; Kuritárné Szabó, Ildikó
2017-05-01
Childhood traumatization plays a significant role in the etiology of borderline personality disorder. Studies found a significant association between childhood traumatization, dissociation, and nonsuicidal self-injurious behavior. The aim of our study was to assess dissociation and nonsuicidal self-injury among borderline inpatients and to reveal the association between childhood traumatization, dissociation, and self-injurious behavior. The sample consisted of 80 borderline inpatients and 73 depressed control patients. Childhood traumatization, dissociation and self-injurious behavior were assessed by questionnaires. Borderline patients reported severe and multiplex childhood traumatization. Cumulative trauma score and sexual abuse were the strongest predictors of dissociation. Furthermore, we have found that cumulative trauma score and dissociation were highly predictive of self-injurious behavior. Our results suggest that self-injurious behavior and dissociation in borderline patients can be regarded as indicators of childhood traumatization. Orv Hetil. 2017; 158(19): 740-747.
Somma, Antonella; Sharp, Carla; Borroni, Serena; Fossati, Andrea
2017-02-01
In order to assess the relationships among borderline personality disorder features, non-suicidal self-injury (NSSI) and emotion dysregulation, 122 community-dwelling Italian adolescents were administered by the Italian translations of the Borderline Personality Features Scale for Children-11, the Deliberate Self-Harm Inventory and the Difficulties in Emotion Regulation Scale (DERS). Regression models showed that both Deliberate Self-Harm Inventory (DSHI) and DERS scores significantly predicted Borderline Personality Features Scale for Children-11 total score; moreover, the DSHI total score significantly predicted the DERS total score. Our findings suggest that borderline personality features in adolescence are moderately, albeit significantly related to NSSI, and that emotion dysregulation does not completely account for the association between borderline personality features and NSSI, although it seems to explain a non-trivial proportion of this relationship. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Reuter, Tyson R; Sharp, Carla; Kalpakci, Allison H; Choi, Hye J; Temple, Jeff R
2016-10-01
Empirical literature demonstrates that sexual minorities are at an increased risk of developing psychopathology, including borderline personality disorder (BPD). The specific link between sexual orientation and BPD has received significantly less attention in youth, and it remains unclear what drives this relation. Given that there are higher rates of psychopathology in both sexual minorities and individuals with BPD, the present study aimed to determine if sexual orientation uniquely contributes to borderline personality pathology, controlling for other psychopathology. An ethnically diverse sample of 835 adolescents completed self-report measures of borderline features, depression, anxiety, and sexual orientation. Sexual minorities scored higher on borderline features compared to heterosexual adolescents. When controlling for depression and anxiety, sexual orientation remained significantly associated with borderline features. The relation between sexual orientation and BPD cannot fully be explained by other psychopathology. Future research is necessary to understand potential mechanisms underlying this relation.
NASA Astrophysics Data System (ADS)
Danylov, Andriy A.; Waldman, Jerry; Light, Alexander R.; Goyette, Thomas M.; Giles, Robert H.; Qian, Xifeng; Chandrayan, Neelima; Goodhue, William D.; Nixon, William E.
2012-02-01
Operational temperature increase of CW THz QCLs to 77 K has enabled us to employ solid nitrogen (SN2) as the cryogen. A roughing pump was used to solidify liquid nitrogen and when the residual vapor pressure in the nitrogen reservoir reached the pumping system's minimum pressure the temperature equilibrated and remained constant until all the nitrogen sublimated. The hold time compared to liquid helium has thereby increased approximately 70-fold, and at a greatly reduced cost. The milliwatt CW QCL was at a temperature of approximately 60 K, dissipating 5 W of electrical power. To measure the long-term frequency, current, and temperature stability, we heterodyned the free-running 2.31 THz QCL with a CO2 pumped far-infrared gas laser line in methanol (2.314 THz) in a corner-cube Schottky diode and recorded the IF frequency, current and temperature. Under these conditions the performance characteristics of the QCL, which will be reported, exceeded that of a device mounted in a mechanical cryocooler.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cirrito, A.J.
Combustion jet pumps ingest waste heat gases from power plant engines and boilers to boost their pressure for the ultimate low temperature utilization of the captured heat for heating homes, full-year hot houses, sterilization purposes, recreational hot water, absorption refrigeration and the like. Jet pump energy is sustained from the incineration of solids, liquids and gases and vapors or simply from burning fuels. This is the energy needed to transport the reaction products to the point of heat utilization and to optimize the heat transfer to that point. Sequent jet pumps raise and preserve energy levels. Crypto-steady and special jetmore » pumps increase pumping efficiency. The distribution conduit accepts fluidized solids, liquids, gases and vapors in multiphase flow. Temperature modulation and flow augmentation takes place by water injection. Macro solids such as dried sewage waste are removed by cyclone separation. Micro particles remain entrained and pass out with waste condensate just beyond each point of final heat utilization to recharge the water table. The non-condensible gases separated at this point are treated for pollution control. Further, jet pump reactions are controlled to yield fuel gas as necessary to power jet pumps or other use. In all these effects introduced sequentially, the available energy necessary to provide the flow energy, for the continuously distributed heating medium, is first extracted from fuel and fuel-like additions to the stream. As all energy, any way, finally converts to heat, which in this case is retained or recaptured in the flow, the captured heat is practically 90% available at the point of low temperature utilization. The jet pump for coal gasification is also disclosed as are examples of coal gasification and hydrogen production.« less
Performance Testing of a Prototypic Annular Linear Induction Pump for Fission Surface Power
NASA Technical Reports Server (NTRS)
Polzin, K. A.; Pearson, J. B.; Schoenfeld, M. P.; Webster, K.; Houts, M. G.; Godfroy, T. J.; Bossard, J. A.
2010-01-01
Results of performance testing of an annular linear induction pump are presented. The pump electromagnetically pumps liquid metal (NaK) through a circuit specially designed to allow for quantification of the performance. Testing was conducted over a range of conditions, including frequencies of 33, 36, 39, and 60 Hz, liquid metal temperatures from 25 to 525 C, and input voltages from 5 to 120 V. Pump performance spanned a range of flow rates from roughly 0.16 to 5.7 L/s (2.5 to 90 gpm), and pressure head <1 to 90 kPa (<0.145 to 13 psi). The maximum efficiency measured during testing was slightly greater than 6%. The efficiency was fairly insensitive to input frequency from 33 to 39 Hz, and was markedly lower at 60 Hz. In addition, the efficiency decreased as the NaK temperature was raised. While the pump was powered, the fluid responded immediately to changes in the input power level, but when power was removed altogether, there was a brief slow-down period before the fluid would come to rest. The performance of the pump operating on a variable frequency drive providing 60 Hz power compared favorably with the same pump operating on 60 Hz power drawn directly from the electrical grid.
Investigation on high transmission efficiency 7 × 1 pump combiner
NASA Astrophysics Data System (ADS)
Cao, Yang; Shi, Wei; Sheng, Quan; Fu, Shijie; Zhang, Haiwei; Bai, Xiaolei; Qi, Liang; Yao, Jianquan
2016-12-01
The 7×1 end-pumped combiner employing 105/125 μm multimode fibers as pump fibers is investigated. The theoretical analysis reveals that sufficient taper length and low refractive index of the capillary should be adopted to fabricate high transmission efficiency combiners. Based on the simulation results, we fabricate a 7×1 end-pumped pump combiner with an average transmission efficiency of 98.9% and a total return loss of 1.1‰. The measured internal operating temperature of this combiner indicates it can endure pump power of the order of kilowatts.
Liquid metal pump for nuclear reactors
Allen, H.G.; Maloney, J.R.
1975-10-01
A pump for use in pumping high temperature liquids at high pressures, particularly liquid metals used to cool nuclear reactors is described. It is of the type in which the rotor is submerged in a sump but is fed by an inlet duct which bypasses the sump. A chamber, kept full of fluid, surrounds the pump casing into which fluid is bled from the pump discharge and from which fluid is fed to the rotor bearings and hence to the sump. This equalizes pressure inside and outside the pump casing and reduces or eliminates the thermal shock to the bearings and sump tank.
Investigation of an ejector heat pump by analytical methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hsu, C.T.
1984-07-01
Using existing theories of ejector design, the optimum geometry of a high-efficiency ejector - including mixing section cross-sectional area, mass flow entrainment rate, ejector efficiency, and overall COP - for a heat pump cycle was determined. A parametric study was performed to evaluate the COP values for different operating conditions. A sensitivity study determined th effects of nozzle efficiency and diffuser efficiency on the overall ejector heat pump COP. The off-design study estimated the COP for an ejector heat pump operating at off-design conditions. Refrigerants 11, 113, and 114 are three of the halocarbons which best satisfy the criteria formore » an ejector heat pump system. The estimated COPs were 0.3 for the cooling mode and 1.3 for the heating mode at standard operating conditions: a boiler temperature of 93.3/sup 0/C (200/sup 0/F), a condenser temperature of 43.3/sup 0/C (110/sup 0/F), and an evaporator temperature of 10/sup 0/C (50/sup 0/F). Based on the same operating conditions, an optimum ejector geometry was estimated for each of the refrigerants R-11 and R-113. Since the COP values for heating obtained in this analysis are greater than unity, the performance of an ejector heat pump operating in the heating mode should be competitive with that of oil- or gas-fired furnaces or electrical resistance heaters.« less
Shame and implicit self-concept in women with borderline personality disorder.
Rüsch, Nicolas; Lieb, Klaus; Göttler, Ines; Hermann, Christiane; Schramm, Elisabeth; Richter, Harald; Jacob, Gitta A; Corrigan, Patrick W; Bohus, Martin
2007-03-01
Shame is considered to be a central emotion in borderline personality disorder and to be related to self-injurious behavior, chronic suicidality, and anger-hostility. However, its level and impact on people with borderline personality disorder are largely unknown. The authors examined levels of self-reported shame, guilt, anxiety, and implicit shame-related self-concept in women with borderline personality disorder and assessed the association of shame with self-esteem, quality of life, and anger-hostility. Sixty women with borderline personality disorder completed self-report measures of shame- and guilt-proneness, state shame, anxiety, depression, self-esteem, quality of life, and clinical symptoms. Comparison groups consisted of 30 women with social phobia and 60 healthy women. Implicit shame-related self-concept (relative to anxiety) was assessed by the Implicit Association Test. Women with borderline personality disorder reported higher levels of shame- and guilt-proneness, state shame, and anxiety than women with social phobia and healthy comparison subjects. The implicit self-concept in women with borderline personality disorder was more shame-prone (relative to anxiety-prone) than in women in the comparison groups. After depression was controlled for, shame-proneness was negatively correlated with self-esteem and quality of life and positively correlated with anger-hostility. Shame, an emotion that is prominent in women with borderline personality disorder, is associated with the implicit self-concept as well as with poorer quality of life and self-esteem and greater anger-hostility. Psychotherapeutic approaches to borderline personality disorder need to address explicit and implicit aspects of shame.
Borderline personality symptoms and work performance: a population-based survey.
Juurlink, Trees T; Ten Have, Margreet; Lamers, Femke; van Marle, Hein J F; Anema, Johannes R; de Graaf, Ron; Beekman, Aartjan T F
2018-06-19
This study aims to elucidate the interplay between borderline personality symptoms and working conditions as a pathway for impaired work performance among workers in the general population. Cross-sectional data from the Netherlands Mental Health Survey and Incidence Study-2 (NEMESIS-2) were used, including 3672 workers. Borderline personality symptoms were measured with the International Personality Disorder Examination (IPDE) questionnaire. Working conditions (decision latitude, psychological job demands, job security and co-worker support) were assessed with the Job Content Questionnaire (JCQ). Impaired work performance was assessed as total work loss days per month, defined as the sum of days of three types of impaired work performance (inability to work, cut-down to work, and diminished quality at work). These were assessed with the WHO Disability Assessment Schedule (WHO-DAS). Common mental disorders (CMD) were assessed with the Composite International Diagnostic Interview (CIDI). Number of borderline personality symptoms was consistently associated with impaired work performance, even after controlling for type or number of adverse working conditions and co-occurrence of CMD. Borderline personality symptoms were associated with low decision latitude, job insecurity and low co-worker support. The relationship between borderline personality symptoms and work performance diminished slightly after controlling for type or number of working conditions. The current study shows that having borderline personality symptoms is a unique determinant of work performance. This association seems partially explained through the impact of borderline personality symptoms on working conditions. Future studies are warranted to study causality and should aim at diminishing borderline personality symptoms and coping with working conditions.
NASA Astrophysics Data System (ADS)
Kasthurirengan, S.; Behera, U.; Vivek, G. A.; Krishnamoorthy, V.; Gangradey, R.; Udgata, S. S.; Tripati, V. S.
2014-01-01
Cryosorption pump is the only possible device to pump helium, hydrogen and its isotopes in fusion environment, such as high magnetic field and high plasma temperatures. Activated carbons are known to be the most suitable adsorbent in the development of cryosorption pumps. For this purpose, the data of adsorption characteristics of activated carbons in the temperature range 4.5 K to 77 K are needed, but are not available in the literature. For obtaining the above data, a commercial micro pore analyzer operating at 77 K has been integrated with a two stage GM cryocooler, which enables the cooling of the sample temperature down to 4.5 K. A heat switch mounted between the second stage cold head and the sample chamber helps to raise the sample chamber temperature to 77 K without affecting the performance of the cryocooler. The detailed description of this system is presented elsewhere. This paper presents the results of experimental studies of adsorption isotherms measured on different types of activated carbons in the form of granules, globules, flake knitted and non-woven types in the temperature range 4.5 K to 10 K using Helium gas as the adsorbate. The above results are analyzed to obtain the pore size distributions and surface areas of the activated carbons. The effect of adhesive used for bonding the activated carbons to the panels is also studied. These results will be useful to arrive at the right choice of activated carbon to be used for the development of cryosorption pumps.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kasthurirengan, S.; Behera, U.; Vivek, G. A.
2014-01-29
Cryosorption pump is the only possible device to pump helium, hydrogen and its isotopes in fusion environment, such as high magnetic field and high plasma temperatures. Activated carbons are known to be the most suitable adsorbent in the development of cryosorption pumps. For this purpose, the data of adsorption characteristics of activated carbons in the temperature range 4.5 K to 77 K are needed, but are not available in the literature. For obtaining the above data, a commercial micro pore analyzer operating at 77 K has been integrated with a two stage GM cryocooler, which enables the cooling of themore » sample temperature down to 4.5 K. A heat switch mounted between the second stage cold head and the sample chamber helps to raise the sample chamber temperature to 77 K without affecting the performance of the cryocooler. The detailed description of this system is presented elsewhere. This paper presents the results of experimental studies of adsorption isotherms measured on different types of activated carbons in the form of granules, globules, flake knitted and non-woven types in the temperature range 4.5 K to 10 K using Helium gas as the adsorbate. The above results are analyzed to obtain the pore size distributions and surface areas of the activated carbons. The effect of adhesive used for bonding the activated carbons to the panels is also studied. These results will be useful to arrive at the right choice of activated carbon to be used for the development of cryosorption pumps.« less
Influence of temperature on Yb:YAG/Cr:YAG microchip laser operation
NASA Astrophysics Data System (ADS)
Šulc, Jan; Eisenschreiber, Jan; Jelínková, Helena; Nejezchleb, Karel; Å koda, Václav
2017-02-01
The goal of this work was an investigation of the temperature influence (in range from 80 up to 320 K) on the laser properties of Yb:YAG/Cr:YAG Q-switched diode-pumped microchip laser. This laser was based on monolith crystal (diameter 3mm) which combines in one piece an active laser part (Yb:YAG crystal, 10 at.% Yb/Y, 3mm long) and saturable absorber (Cr:YAG crystal, 1.36mm long, initial transmission 90% @ 1031 nm). The laser resonator pump mirror (HT for pump radiation, HR for generated radiation) was directly deposited on the Yb:YAG monolith part. The output coupler with reflection 55% for the generated wavelength was placed on the Cr:YAG part. The microchip laser was placed in the temperature controlled cupreous holder inside vacuum chamber of the liquid nitrogen cryostat. For Yb:YAG part longitudinal pulsed pumping (pumping pulse length 2.5 ms, rep-rate 20 Hz, power amplitude 21W) a fibre coupled (core diameter 400 μm, NA= 0:22) laser diode, operating at wavelength 933 nm, was used. The microchip laser mean output power, pulse duration, repetition rate, emission wavelength, and laser beam profile were measured in dependence on temperature. The generated pulse length was in range from 2.2 ns to 1.1 ns (FWHM) with the minimum at 230 K. The single pulse energy was peaking (0.4 mJ) at 180 K. The highest peak power (325 kW) was obtained at 220 K. The highest pulse repetition rate (38 kHz) and output mean power (370mW) was reached for temperature 80 K.
125-mJ diode-pumped injection-seeded Ho:Tm:YLF laser.
Yu, J; Singh, U N; Barnes, N P; Petros, M
1998-05-15
We describe a diode-pumped, room-temperature Ho:Tm:YLF power oscillator with an optical-to-optical efficiency of 0.03. A Q -switched output energy of as much as 125 mJ at 6 Hz with a pulse width of 170 ns was obtained. Single-frequency, nearly transform-limited operation of the laser was achieved by injection seeding. Laser performance as a function of laser rod temperature and pump intensity was also investigated. The high power and high beam quality of this laser make it well suited for use as a coherent wind lidar transmitter on a space platform.
Determination of Ground Heat Exchangers Temperature Field in Geothermal Heat Pumps
NASA Astrophysics Data System (ADS)
Zhurmilova, I.; Shtym, A.
2017-11-01
For the heating and cooling supply of buildings and constructions geothermal heat pumps using low-potential ground energy are applied by means of ground exchangers. The process of heat transfer in a system of ground exchangers is a phenomenon of complex heat transfer. The paper presents a mathematical modeling of heat exchange processes, the temperature fields are built which are necessary for the determination of the ground array that ensures an adequate supply of low potential energy excluding the freezing of soil around the pipes in the ground heat exchangers and guaranteeing a reliable operation of geothermal heat pumps.
Ballistic induced pumping of hypersonic heat current in DNA nano wire
NASA Astrophysics Data System (ADS)
Behnia, Sohrab; Panahinia, Robabe
2016-12-01
Heat shuttling properties of DNA nano-wire driven by an external force against the spontaneous heat current direction in non-zero temperature bias (non averaged) have been studied. We examined the valid region of driving amplitude and frequency to have pumping state in terms of temperature bias and the system size. It was shown that DNA could act as a high efficiency thermal pump in the hypersonic region. Amplitude-dependent resonance frequencies of DNA indicating intrinsic base pair internal vibrations have been detected. Nonlinearity implies that by increasing the driven amplitude new vibration modes are detected. To verify the results, an analytical parallel investigation based on multifractal concept has been done. By using the geometric properties of the strange attractor of the system, the threshold value to transition to the pumping state for given external amplitude has been identified. It was shown that the system undergoes a phase transition in sliding point to the pumping state. Fractal dimension demonstrates that the ballistic transport is responsible for energy pumping in the system. In the forbidden band gap, DNA could transmit the energy by exceeding the threshold amplitude. Despite of success in energy pumping, in this framework, DNA could not act as a real cooler.
Diode pumped Nd:YAG laser development
NASA Technical Reports Server (NTRS)
Reno, C. W.; Herzog, D. G.
1976-01-01
A low power Nd:YAG laser was constructed which employs GaAs injection lasers as a pump source. Power outputs of 125 mW TEM CW with the rod at 250 K and the pump at 180 K were achieved for 45 W input power to the pump source. Operation of the laser, with array and laser at a common heat sink temperature of 250 K, was inhibited by difficulties in constructing long-life GaAs LOC laser arrays. Tests verified pumping with output power of 20 to 30 mW with rod and pump at 250 K. Although life tests with single LOC GaAs diodes were somewhat encouraging (with single diodes operating as long as 9000 hours without degradation), failures of single diodes in arrays continue to occur, and 50 percent power is lost in a few hundred hours at 1 percent duty factor. Because of the large recent advances in the state of the art of CW room temperature AlGaAs diodes, their demonstrated lifetimes of greater than 5,000 hours, and their inherent advantages for this task, it is recommended that these sources be used for further CW YAG injection laser pumping work.
Absorption heat pump for space applications
NASA Technical Reports Server (NTRS)
Nguyen, Tuan; Simon, William E.; Warrier, Gopinath R.; Woramontri, Woranun
1993-01-01
In the first part, the performance of the Absorption Heat Pump (AHP) with water-sulfuric acid and water-magnesium chloride as two new refrigerant-absorbent fluid pairs was investigated. A model was proposed for the analysis of the new working pairs in a heat pump system, subject to different temperature lifts. Computer codes were developed to calculate the Coefficient of Performance (COP) of the system with the thermodynamic properties of the working fluids obtained from the literature. The study shows the potential of water-sulfuric acid as a satisfactory replacement for water-lithium bromide in the targeted temperature range. The performance of the AHP using water-magnesium chloride as refrigerant-absorbent pair does not compare well with those obtained using water-lithium bromide. The second part concentrated on the design and testing of a simple ElectroHydrodynamic (EHD) Pump. A theoretical design model based on continuum electromechanics was analyzed to predict the performance characteristics of the EHD pump to circulate the fluid in the absorption heat pump. A numerical method of solving the governing equations was established to predict the velocity profile, pressure - flow rate relationship and efficiency of the pump. The predicted operational characteristics of the EHD pump is comparable to that of turbomachinery hardware; however, the overall efficiency of the electromagnetic pump is much lower. An experimental investigation to verify the numerical results was conducted. The pressure - flow rate performance characteristics and overall efficiency of the pump obtained experimentally agree well with the theoretical model.
Gene-Environment Studies and Borderline Personality Disorder: A Review
Carpenter, Ryan W.; Tomko, Rachel L.; Boomsma, Dorret I.
2014-01-01
We review recent gene-environment studies relevant to borderline personality disorder, including those focusing on impulsivity, emotion sensitivity, suicidal behavior, aggression and anger, and the borderline personality phenotype itself. Almost all the studies reviewed suffered from a number of methodological and statistical problems, limiting the conclusions that currently can be drawn. The best evidence to date supports a gene-environment correlation (rGE) model for borderline personality traits and a range of adverse life events, indicating that those at risk for BPD are also at increased risk for exposure to environments that may trigger BPD. We provide suggestions regarding future research on GxE interaction and rGE effects in borderline personality. PMID:23250817
NASA Astrophysics Data System (ADS)
Nishihara, Munetake; Freund, Jonathan B.; Glumac, Nick G.; Elliott, Gregory S.
2018-03-01
This paper presents dual-pump coherent anti-Stokes Raman scattering (CARS) measurements for simultaneous detection of flow temperature and relative concentration, applied to the characterization of a discharge-coupled reacting jet in a cross flow. The diagnostic is hydrogen Q-branch based, providing a much wider dynamic range compared to detection in the S-branch. For a previously developed dielectric barrier discharge, aligned co-axially with the fuel jet, OH planar laser induced fluorescence measurements show that the disturbance in the flame boundary leads to mixing enhancement. The H2-N2 dual-pump CARS measurement was used to map two-dimensional temperature distributions. The increase of the maximum temperature was up to 300 K, with 50% more H2 consumption, providing the reason for the decrease in the flame length by 25%. The increase of the relative H2O-H2 fraction was accompanied with a temperature increase, which indicates local equivalence ratios of below 1. The H2-O2 dual-pump measurements confirmed that the fuel-oxidizer ratios remain in the fuel-lean side at most of the probed locations.
Neural network approach to prediction of temperatures around groundwater heat pump systems
NASA Astrophysics Data System (ADS)
Lo Russo, Stefano; Taddia, Glenda; Gnavi, Loretta; Verda, Vittorio
2014-01-01
A fundamental aspect in groundwater heat pump (GWHP) plant design is the correct evaluation of the thermally affected zone that develops around the injection well. This is particularly important to avoid interference with previously existing groundwater uses (wells) and underground structures. Temperature anomalies are detected through numerical methods. Computational fluid dynamic (CFD) models are widely used in this field because they offer the opportunity to calculate the time evolution of the thermal plume produced by a heat pump. The use of neural networks is proposed to determine the time evolution of the groundwater temperature downstream of an installation as a function of the possible utilization profiles of the heat pump. The main advantage of neural network modeling is the possibility of evaluating a large number of scenarios in a very short time, which is very useful for the preliminary analysis of future multiple installations. The neural network is trained using the results from a CFD model (FEFLOW) applied to the installation at Politecnico di Torino (Italy) under several operating conditions. The final results appeared to be reliable and the temperature anomalies around the injection well appeared to be well predicted.
Thermally Actuated Hydraulic Pumps
NASA Technical Reports Server (NTRS)
Jones, Jack; Ross, Ronald; Chao, Yi
2008-01-01
Thermally actuated hydraulic pumps have been proposed for diverse applications in which direct electrical or mechanical actuation is undesirable and the relative slowness of thermal actuation can be tolerated. The proposed pumps would not contain any sliding (wearing) parts in their compressors and, hence, could have long operational lifetimes. The basic principle of a pump according to the proposal is to utilize the thermal expansion and contraction of a wax or other phase-change material in contact with a hydraulic fluid in a rigid chamber. Heating the chamber and its contents from below to above the melting temperature of the phase-change material would cause the material to expand significantly, thus causing a substantial increase in hydraulic pressure and/or a substantial displacement of hydraulic fluid out of the chamber. Similarly, cooling the chamber and its contents from above to below the melting temperature of the phase-change material would cause the material to contract significantly, thus causing a substantial decrease in hydraulic pressure and/or a substantial displacement of hydraulic fluid into the chamber. The displacement of the hydraulic fluid could be used to drive a piston. The figure illustrates a simple example of a hydraulic jack driven by a thermally actuated hydraulic pump. The pump chamber would be a cylinder containing encapsulated wax pellets and containing radial fins to facilitate transfer of heat to and from the wax. The plastic encapsulation would serve as an oil/wax barrier and the remaining interior space could be filled with hydraulic oil. A filter would retain the encapsulated wax particles in the pump chamber while allowing the hydraulic oil to flow into and out of the chamber. In one important class of potential applications, thermally actuated hydraulic pumps, exploiting vertical ocean temperature gradients for heating and cooling as needed, would be used to vary hydraulic pressures to control buoyancy in undersea research vessels. Heretofore, electrically actuated hydraulic pumps have been used for this purpose. By eliminating the demand for electrical energy for pumping, the use of the thermally actuated hydraulic pumps could prolong the intervals between battery charges, thus making it possible to greatly increase the durations of undersea exploratory missions.
Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J
2017-01-01
Introduction Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. Methods and analysis The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4–7 days, followed by the other for a further 4–7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. Ethics and dissemination This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform future device selection. Trial registration number ACTRN12617000251325; Pre-results. PMID:28760798
Hobbs, Jodie G; Ryan, Melissa K; Ritchie, Brett; Sluggett, Janet K; Sluggett, Andrew J; Ralton, Lucy; Reynolds, Karen J
2017-07-31
Previous studies comparing satisfaction with electronic and elastomeric infusion pumps are limited, and improvements in size and usability of electronic pumps have since occurred. The Comparing Home Infusion Devices (CHID) study plans to assess patient and nurse satisfaction with an elastomeric and electronic pump for delivering intravenous antibiotic treatment in the home. Secondary objectives are to determine pump-related complications and actual antibiotic dose administered, evaluate temperature variation and compare pump operating costs. The CHID study will be a randomised, crossover trial. A trained research nurse will recruit patients with infectious disease aged ≥18 years and prescribed ≥8 days of continuous intravenous antibiotic therapy from the Royal Adelaide Hospital (RAH) (Adelaide, Australia). Patients will be randomised to receive treatment at home via an elastomeric (Baxter Infusor) or an electronic (ambIT Continuous) infusion pump for 4-7 days, followed by the other for a further 4-7 days. Patient satisfaction will be assessed by a 10-item survey to be completed at the end of each arm. Nurse satisfaction will be assessed by a single 24-item survey. Patient logbooks and case notes from clinic visits will be screened to identify complications. Pumps/infusion bags will be weighed to estimate the volume of solution delivered. Temperature sensors will record skin and ambient temperatures during storage and use of the pumps throughout the infusion period. Costs relating to pumps, consumables, antibiotics and servicing will be determined. Descriptive statistics will summarise study data. This study has been approved by the RAH Human Research Ethics Committee (HREC/16/RAH/133 R20160420, version 6.0, 5 September 2016). Study results will be disseminated through peer-reviewed publications and conference presentations. The CHID study will provide key insights into patient and provider satisfaction with elastomeric and electronic infusion pumps and inform future device selection. ACTRN12617000251325; Pre-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Zanarini, Mary C; Temes, Christina M; Frankenburg, Frances R; Reich, D Bradford; Fitzmaurice, Garrett M
2018-04-01
One purpose of this study was to determine the cumulative rates of excellent recovery for borderline patients and axis II comparison subjects followed prospectively for 20 years. Another purpose was to find the best set of baseline predictors of excellent recovery for borderline patients. A total of 290 inpatients meeting rigorous criteria for borderline personality disorder and 72 axis II comparison subjects completed semistructured interviews and self-report measures during their index admission. Subjects were reassessed prospectively over 10 contiguous two-year waves of follow-up. Thirty-nine percent of borderline patients and 73% of personality-disordered comparison subjects met our operationalized definition of excellent recovery (concurrent remission of borderline or another primary personality disorder, good social and full-time vocational functioning, and absence of an axis I disorder associated decreased social and/or vocational functioning). Five variables formed our multivariate predictive model of excellent recovery for borderline patients: higher IQ, good childhood work history, good adult vocational record, lower trait neuroticism, and higher trait agreeableness. The results of this study suggest that complete recovery is difficult for borderline patients to achieve even over long periods of time. They also suggest that competence displayed in both childhood and adulthood is the best predictor of this important outcome. Copyright © 2018 Elsevier B.V. All rights reserved.
Borderline personality features in depressed or anxious patients.
Distel, Marijn A; Smit, Johannes H; Spinhoven, Philip; Penninx, Brenda W J H
2016-07-30
Anxiety and depression frequently co-occur with borderline personality disorder. Relatively little research examined the presence of borderline personality features and its main domains (affective instability, identity problems, negative relationships and self-harm) in individuals with remitted and current anxiety and depression. Participants with current (n=597) or remitted (n=1115) anxiety and/or depression and healthy controls (n=431) were selected from the Netherlands Study of Depression and Anxiety. Assessments included the Personality Assessment Inventory - Borderline Features Scale and several clinical characteristics of anxiety and depression. Borderline personality features were more common in depression than in anxiety. Current comorbid anxiety and depression was associated with most borderline personality features. Anxiety and depression status explained 29.7% of the variance in borderline personality features and 3.8% (self-harm) to 31% (identity problems) of the variance in the four domains. A large part of the variance was shared between anxiety and depression but both disorders also explained a significant amount of unique variance. The severity of anxiety and depression and the level of daily dysfunctioning was positively associated with borderline personality features. Individuals with a longer duration of anxiety and depression showed more affective instability and identity problems. These findings suggest that patients with anxiety and depression may benefit from an assessment of personality pathology as it may have implications for psychological and pharmacological treatment. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Sajadi, Seyede Fateme; Arshadi, Nasrin; Zargar, Yadolla; Mehrabizade Honarmand, Mahnaz; Hajjari, Zahra
2015-06-01
Numerous studies have demonstrated that early maladaptive schemas, emotional dysregulation are supposed to be the defining core of borderline personality disorder. Many studies have also found a strong association between the diagnosis of borderline personality and the occurrence of suicide ideation and dissociative symptoms. The present study was designed to investigate the relationship between borderline personality features and schema, emotion regulation, dissociative experiences and suicidal ideation among high school students in Shiraz City, Iran. In this descriptive correlational study, 300 students (150 boys and 150 girls) were selected from the high schools in Shiraz, Iran, using the multi-stage random sampling. Data were collected using some instruments including borderline personality feature scale for children, young schema questionnaire-short form, difficulties in emotion-regulation scale (DERS), dissociative experience scale and beck suicide ideation scale. Data were analyzed using the Pearson correlation coefficient and multivariate regression analysis. The results showed a significant positive correlation between schema, emotion regulation, dissociative experiences and suicide ideation with borderline personality features. Moreover, the results of multivariate regression analysis suggested that among the studied variables, schema was the most effective predicting variable of borderline features (P < 0.001). The findings of this study are in accordance with findings from previous studies, and generally show a meaningful association between schema, emotion regulation, dissociative experiences, and suicide ideation with borderline personality features.
Merrett, Zalie; Rossell, Susan L; Castle, David J
2016-07-01
In clinical settings, there is substantial evidence both clinically and empirically to suggest that approximately 50% of individuals with borderline personality disorder experience auditory verbal hallucinations. However, there is limited research investigating the phenomenology of these voices. The aim of this study was to review and compare our current understanding of auditory verbal hallucinations in borderline personality disorder with auditory verbal hallucinations in patients with a psychotic disorder, to critically analyse existing studies investigating auditory verbal hallucinations in borderline personality disorder and to identify gaps in current knowledge, which will help direct future research. The literature was searched using the electronic database Scopus, PubMed and MEDLINE. Relevant studies were included if they were written in English, were empirical studies specifically addressing auditory verbal hallucinations and borderline personality disorder, were peer reviewed, used only adult humans and sample comprising borderline personality disorder as the primary diagnosis, and included a comparison group with a primary psychotic disorder such as schizophrenia. Our search strategy revealed a total of 16 articles investigating the phenomenology of auditory verbal hallucinations in borderline personality disorder. Some studies provided evidence to suggest that the voice experiences in borderline personality disorder are similar to those experienced by people with schizophrenia, for example, occur inside the head, and often involved persecutory voices. Other studies revealed some differences between schizophrenia and borderline personality disorder voice experiences, with the borderline personality disorder voices sounding more derogatory and self-critical in nature and the voice-hearers' response to the voices were more emotionally resistive. Furthermore, in one study, the schizophrenia group's voices resulted in more disruption in daily functioning. These studies are, however, limited in number and do not provide definitive evidence of these differences. The limited research examining auditory verbal hallucinations experiences in borderline personality disorder poses a significant diagnostic and treatment challenge. A deeper understanding of the precise phenomenological characteristics will help us in terms of diagnostic distinction as well as inform treatments. © The Royal Australian and New Zealand College of Psychiatrists 2016.
de la Rosa, Iris; Oquendo, María A; García, Gemma; Stanley, Barbara; González-Pinto, Ana; Liu, Shang-Min; Blanco, Carlos
To examine whether bipolar disorder and borderline personality disorder represent 2 different disorders or alternative manifestations of the same disorder. The data were collected between January 1, 2004, and December 31, 2005. The analyses were conducted between December 21 and December 27, 2010. Exploratory factor analysis (EFA) and confirmatory factor analysis (CFA) were performed on 25 symptoms assessing depression, mania, and borderline personality disorder from the National Epidemiologic Survey on Alcohol and Related Conditions, a large nationally representative sample of the US adult population (N = 34,653). DSM-IV criteria were used for diagnosis of bipolar disorder and borderline personality disorder. A 3-factor solution provided an excellent fit in both the EFA (root mean square error of approximation [RMSEA] = 0.017, comparative fix index [CFI] = 0.997) and the CFA (RMSEA = 0.024, CFI = 0.993). Factor 1 (Borderline Personality Disorder) loaded on all 9 borderline personality disorder symptoms, factor 2 (Depression) loaded on 8 symptoms of depression, and factor 3 (Mania) loaded on 7 symptoms of mania plus the psychomotor agitation item of the depression section. The correlations between the Borderline Personality Disorder and Depression factors (r = 0.328) and between the Borderline Personality Disorder and Mania factors (r = 0.394) were lower than the correlation between Depression and Mania factors (r = 0.538). A model with 3 positively correlated factors provided an excellent fit for the latent structure of borderline personality disorder and bipolar disorder symptoms. The pattern of pairwise correlations between the 3 factors is consistent with the clinical presentation of 2 syndromes (depression and mania) that can be characterized as a unitary psychiatric entity (bipolar disorder) and a third syndrome (borderline personality disorder) that is often comorbid with bipolar disorder. The findings converge in suggesting that bipolar disorder and borderline personality disorder are overlapping but different pathologies. These findings may serve to inform ongoing efforts to refine the existing psychiatric nosology and to suggest new avenues for etiologic and treatment research. © Copyright 2017 Physicians Postgraduate Press, Inc.
Regenerative Hydride Heat Pump
NASA Technical Reports Server (NTRS)
Jones, Jack A.
1992-01-01
Hydride heat pump features regenerative heating and single circulation loop. Counterflow heat exchangers accommodate different temperatures of FeTi and LaNi4.7Al0.3 subloops. Heating scheme increases efficiency.
Heberle, Anita Batista dos Santos; de Moura, Marcos Antônio Muniz; de Souza, Mauren Abreu; Nohama, Percy
2014-01-01
Objective to evaluate techniques of massage and pumping in the treatment of postpartum breast engorgement through thermography. Method the study was conducted in the Human Milk Bank of a hospital in Curitiba, Brazil. We randomly selected 16 lactating women with engorgement with the classification lobar, ampullary and glandular, moderate and intense. We compared the differential patterns of temperature, before and after the treatment by means of massage and pumping. Results we found a negative gradient of 0.3°C of temperature between the pre- and post-treatment in the experimental group. Breasts with intense engorgement were 0.7°C warmer when compared with moderate engorgement. Conclusion massage and electromechanical pumping were superior to manual methods when evaluated by thermography. REBEC: U1111-1136-9027. PMID:26107836
Solar pumped continuous wave carbon dioxide laser
NASA Technical Reports Server (NTRS)
Yesil, O.; Christiansen, W. H.
1978-01-01
In an effort to demonstrate the feasibility of a solar pumped laser concept, gain has been measured in a CO2-He laser medium optically pumped by blackbody radiation. Various gas mixtures of CO2 and He have been pumped by blackbody radiation emitted from an electrically heated oven. Using a CO2 laser as a probe, an optical gain coefficient of 1.8 x 10 to the -3rd/cm has been measured at 10.6 microns for a 9:1 CO2-He mixture at an oven temperature of about 1500 K, a gas temperature of about 400 K and a pressure of about 1 torr. This corresponds to a small signal gain coefficient when allowance is made for saturation effects due to the probe beam, in reasonable agreement with a theoretical value.
NASA Technical Reports Server (NTRS)
Daggerhart, J. A.
1972-01-01
The use of cryopumping techniques to obtain a contamination free vacuum is discussed. Of those gases that are normally present in an initially air filled vacuum system, only carbon dioxide and water vapor will be effectively pumped at 77 degrees Kelvin. In order to circumvent this restriction on the types of gases that are pumped at this temperature, it is postulated that a gas which is easily condensable at 77 degrees K be injected into the system in the form of a directed stream. The stream would then entrain the normally noncondensable species by a momentum transfer mechanism. After sweeping through the volume to be pumped, the injected gas stream would then be condensed on a cryopumping surface maintained at 77 degrees Kelvin.
Spin accumulation in permalloy-ZnO heterostructures from both electrical injection and spin pumping
NASA Astrophysics Data System (ADS)
Wang, Xiaowei; Yang, Yumeng; Wang, Ying; Luo, Ziyan; Xie, Hang; Wu, Yihong
2017-11-01
We report the results of room temperature spin injection and detection studies in ZnO using both electrical injection and spin pumping. At ferromagnetic resonance, an interfacial voltage with a constant polarity upon magnetization reversal is observed in permalloy-ZnO heterostructures, which is attributed to spin accumulation after ruling out other origins. Simultaneous electrical injection during spin pumping is achieved in samples with large interface resistance or insertion of a thin MgO layer at the interface of permalloy and ZnO. From the pumping frequency dependence of detected voltage, a spin lifetime of 32 ps is extracted for ZnO at room temperature, despite the fact that there was no Hanle effect observed in the same device using the conventional three-terminal DC measurement.
VOLUME COMPENSATING MEANS FOR PULSATING PUMPS
Weaver, D.L.W.; MacCormack, R.S. Jr.
1959-12-01
A double diaphragm, two-liquid pulsating pump for remote control use, having as an improvement an apparatus for maintaining constant the volume of the liquid such as kerosene between the two diaphragms is described. Phase difficulties encountered in the operation of such pumps when the volume of the liquid is altered by changes in temperature are avoided.
Heat pumping in nanomechanical systems.
Chamon, Claudio; Mucciolo, Eduardo R; Arrachea, Liliana; Capaz, Rodrigo B
2011-04-01
We propose using a phonon pumping mechanism to transfer heat from a cold to a hot body using a propagating modulation of the medium connecting the two bodies. This phonon pump can cool nanomechanical systems without the need for active feedback. We compute the lowest temperature that this refrigerator can achieve. © 2011 American Physical Society
Miniature thermo-electric cooled cryogenic pump
Keville, R.F.
1997-11-18
A miniature thermo-electric cooled cryogenic pump is described for removing residual water molecules from an inlet sample prior to sample analysis in a mass spectroscopy system, such as ion cyclotron resonance (ICR) mass spectroscopy. The cryogenic pump is a battery operated, low power (<1.6 watts) pump with a {Delta}T=100 C characteristic. The pump operates under vacuum pressures of 5{times}10{sup {minus}4} Torr to ultra high vacuum (UHV) conditions in the range of 1{times}10{sup {minus}7} to 3{times}10{sup {minus}9} Torr and will typically remove partial pressure, 2{times}10{sup {minus}7} Torr, residual water vapor. The cryogenic pump basically consists of an inlet flange piece, a copper heat sink with a square internal bore, four two tier Peltier (TEC) chips, a copper low temperature square cross sectional tubulation, an electronic receptacle, and an exit flange piece, with the low temperature tubulation being retained in the heat sink at a bias angle of 5{degree}, and with the TECs being positioned in parallel to each other with a positive potential being applied to the top tier thereof. 2 figs.
Miniature thermo-electric cooled cryogenic pump
Keville, Robert F.
1997-01-01
A miniature thermo-electric cooled cryogenic pump for removing residual water molecules from an inlet sample prior to sample analysis in a mass spectroscopy system, such as ion cyclotron resonance (ICR) mass spectroscopy. The cryogenic pump is a battery operated, low power (<1.6 watts) pump with a .DELTA.T=100.degree. C. characteristic. The pump operates under vacuum pressures of 5.times.10.sup.-4 Torr to ultra high vacuum (UHV) conditions in the range of 1.times.10.sup.-7 to 3.times.10.sup.-9 Torr and will typically remove partial pressure, 2.times.10.sup.-7 Torr, residual water vapor. The cryogenic pump basically consists of an inlet flange piece, a copper heat sink with a square internal bore, four two tier Peltier (TEC) chips, a copper low temperature square cross sectional tubulation, an electronic receptacle, and an exit flange piece, with the low temperature tubulation being retained in the heat sink at a bias angle of 5.degree., and with the TECs being positioned in parallel to each other with a positive potential being applied to the top tier thereof.
Morphological three-dimensional analysis of papillary muscles in borderline left ventricles.
Velasco Forte, Mari N; Nassar, Mohamed; Byrne, Nick; Silva Vieira, Miguel; Pérez, Israel V; Ruijsink, Bram; Simpson, John; Hussain, Tarique
2017-09-01
Mitral valve anatomy has a significant impact on potential surgical options for patients with hypoplastic or borderline left ventricle. Papillary muscle morphology is a major component regarding this aspect. The purpose of this study was to use cardiac magnetic resonance to describe the differences in papillary muscle anatomy between normal, borderline, and hypoplastic left ventricles. We carried out a retrospective, observational cardiac magnetic resonance study of children (median age 5.36 years) with normal (n=30), borderline (n=22), or hypoplastic (n=13) left ventricles. Borderline and hypoplastic cases had undergone an initial hybrid procedure. Morphological features of the papillary muscles, location, and arrangement were analysed and compared across groups. All normal ventricles had two papillary muscles with narrow pedicles; however, 18% of borderline and 46% of hypoplastic cases had a single papillary muscle, usually the inferomedial type. In addition, in borderline or hypoplastic ventricles, the supporting pedicle occasionally displayed a wide insertion along the ventricular wall. The length ratio of the superolateral support was significantly different between groups (normal: 0.46±0.08; borderline: 0.39±0.07; hypoplastic: 0.36±0.1; p=0.009). No significant difference, however, was found when analysing the inferomedial type (0.42±0.09; 0.38±0.07; 0.39±0.22, p=0.39). The angle subtended between supports was also similar among groups (113°±17°; 111°±51° and 114°±57°; p=0.99). A total of eight children with borderline left ventricle underwent biventricular repair. There were no significant differentiating features for papillary muscle morphology in this subgroup. The superolateral support can be shorter or absent in borderline or hypoplastic left ventricle cases. The papillary muscle pedicles in these patients often show a broad insertion. These changes have important implications on surgical options and should be described routinely.
Monolithic Teflon membrane valves and pumps for harsh chemical and low-temperature use.
Willis, Peter A; Hunt, Brian D; White, Victor E; Lee, Michael C; Ikeda, Michael; Bae, Sam; Pelletier, Michael J; Grunthaner, Frank J
2007-11-01
Microfluidic diaphragm valves and pumps capable of surviving conditions required for unmanned spaceflight applications have been developed. The Pasteur payload of the European ExoMars Rover is expected to experience temperatures ranging between -100 degrees C and +50 degrees C during its transit to Mars and on the Martian surface. As such, the Urey instrument package, which contains at its core a lab-on-a-chip capillary electrophoresis analysis system first demonstrated by Mathies et al., requires valving and pumping systems that are robust under these conditions before and after exposure to liquid samples, which are to be analyzed for chemical signatures of past or present living processes. The microfluidic system developed to meet this requirement uses membranes consisting of Teflon and Teflon AF as a deformable material in the valve seat region between etched Borofloat glass wafers. Pneumatic pressure and vacuum, delivered via off-chip solenoid valves, are used to actuate individual on-chip valves. Valve sealing properties of Teflon diaphragm valves, as well as pumping properties from collections of valves, are characterized. Secondary processing for embossing the membrane against the valve seats after fabrication is performed to optimize single valve sealing characteristics. A variety of different material solutions are found to produce robust devices. The optimal valve system utilizes a membrane of mechanically cut Teflon sandwiched between two thin spun films of Teflon AF-1600 as a composite "laminated" diaphragm. Pump rates up to 1600 nL s(-1) are achieved with pumps of this kind. These high pumping rates are possible because of the very fast response of the membranes to applied pressure, enabling extremely fast pump cycling with relatively small liquid volumes, compared to analogous diaphragm pumps. The developed technologies are robust over extremes of temperature cycling and are applicable in a wide range of chemical environments.
Preliminary design of a Primary Loop Pump Assembly (PLPA), using electromagnetic pumps
NASA Technical Reports Server (NTRS)
Moss, T. A.; Matlin, G.; Donelan, L.; Johnson, J. L.; Rowe, I.
1972-01-01
A preliminary design study of flight-type dc conduction-permanent magnetic, ac helical induction, and ac linear induction pumps for circulating 883 K (1130 F) NaK at 9.1 kg/sec (20 lb/sec) is described. Various electromagnetic pump geometrics are evaluated against hydraulic performance, and the effects of multiple windings and numbers of pumps per assembly on overall reliability were determined. The methods used in the electrical-hydraulic, stress, and thermal analysis are discussed, and the high temperature electrical materials selected for the application are listed.
Analysis of geothermal temperatures for heat pumps application in Paraná (Brasil)
NASA Astrophysics Data System (ADS)
Santos, Alexandre F.; de Souza, Heraldo J. L.; Cantao, Mauricio P.; Gaspar, Pedro D.
2016-11-01
Geothermal heat pumps are broadly used in developed countries but scarcely in Brazil, in part because there is a lack of Brazilian soil temperature data. The aims of this work are: to present soil temperature measurements and to compare geothermal heat pump system performances with conventional air conditioning systems. Geothermal temperature measurement results are shown for ten Paraná State cities, representing different soil and climate conditions. The measurements were made yearlong with calibrated equipment and digital data acquisition system in different measuring stations. Geothermal and ambient temperature data were used for simulations of the coeficient of performance (COP), by means of a working fluid pressure-enthalpy diagram based software for vapor-compression cycle. It was verified that geothermal temperature measured between January 13 to October 13, 2013, varied from 16 to 24 °C, while room temperature has varied between 2 and 35 °C. Average COP values for conventional system were 3.7 (cooling mode) and 5.0 kW/kW (heating mode), corresponding to 5.9 and 7.9 kW/kW for geothermal system. Hence it was verified an average eficiency gain of 59%with geothermal system utilization in comparison with conventional system.
Park, Sung Yoon; Oh, Young Taik; Jung, Dae Chul
2016-05-01
There is overlap in imaging features between borderline and benign ovarian tumors. To analyze diagnostic performance of magnetic resonance imaging (MRI) combined with tumor markers for differentiating borderline from benign ovarian tumor. Ninety-nine patient with MRI and surgically confirmed ovarian tumors 5 cm or larger (borderline, n = 37; benign, n = 62) were included. On MRI, tumor size, septal number (0; 1-4; 5 or more), and presence of solid portion such as papillary projection or septal thickening 0.5 cm or larger were investigated. Serum tumor markers (carbohydrate antigen 125 [CA 125] and CA 19-9) were recorded. Multivariate analysis was conducted for assessing whether combined MRI with tumor markers could differentiate borderline from benign tumor. The diagnostic performance was also analyzed. Incidence of solid portion was 67.6% (25/37) in borderline and 3.2% (2/62) in benign tumors (P < 0.05). In all patients, without combined analysis of MRI with tumor markers, multivariate analysis revealed solid portion (P < 0.001) and CA 125 (P = 0.039) were significant for predicting borderline tumors. When combined analysis of MRI with CA 125 ((i) the presence of solid portion or (ii) CA 125 > 44.1 U/mL with septal number ≥5 for borderline tumor) is incorporated to multivariate analysis, it was only significant (P = 0.001). The sensitivity, specificity, PPV, NPV, and accuracy of combined analysis of MRI with CA 125 were 89.1%, 91.9%, 86.8%, 93.4, and 90.9%, respectively. Combined analysis of MRI with CA 125 may allow better differentiation between borderline and benign ovarian tumor compared with MRI alone. © The Foundation Acta Radiologica 2015.
Watad, Abdulla; Bragazzi, Nicola L; Sharif, Kassem; Gilburd, Boris; Yavne, Yarden; McGonagle, Dennis; Amital, Howard; Shoenfeld, Yehuda
2018-05-24
Enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescence (IIF) are the best strategies for antineutrophil cytoplasmic antibodies (ANCA) detection. In a minority of subjects, ELISA-based ANCA testing may result in a borderline positive titre. Therefore, we assessed the clinical significance of such a result. This is a retrospective study, which included all subjects screened for ANCA subtypes (myeloperoxidase (MPO) or proteinase-3 (PR3)) with subsequent identification of borderline positive results, as determined by ELISA and retested using IIF. The demographic, clinical and laboratory data of subjects with borderline positive ANCA test results were extracted from their medical records. A total of 14,555 PR3/MPO-ANCA tests were performed with ELISA during the study period (2006-2016). Of the 14,555 PR3-ANCA antibody tests that were performed, 94 were borderline positive (titre 0.9-1.1), and of 14,555 MPO-ANCA antibody tests, 43 were borderline positive (titre 0.9-1.1). The male-to-female ratio was 1:1.08 and the mean age was 50.95±21.79 years. Four MPO-ANCA (9.30%) and 11 PR3-ANCA (11.70%) antibody borderline samples resulted positive on IIF testing. Subjects with borderline positive MPO-ANCA were found to have a poorer outcome in terms of renal failure and the requirement of dialysis. Subjects with borderline positive MPO-ANCA and positive p-ANCA (IIF) seem to have a less favorable outcome. Physicians should be aware of these findings and possibly perform a closer follow-up and routine screening for these subjects.
Marques, Sofia; Barrocas, Daniel; Rijo, Daniel
2017-04-28
Borderline personality disorder is the most common personality disorder, with a global prevalence rate between 1.6% and 6%. It is characterized by affective disturbance and impulsivity, which lead to a high number of self-harm behaviors and great amount of health services use. International guidelines recommend psychotherapy as the primary treatment for borderline personality disorder. This paper reviews evidence about the effects and efficacy of cognitive-behavioral oriented psychological treatments for borderline personality disorder. A literature review was conducted in Medline and PubMed databases, using the following keywords: borderline personality disorder, cognitive-behavioral psychotherapy and efficacy. Sixteen randomized clinical trials were evaluate in this review, which analyzed the effects of several cognitive-behavioral oriented psychotherapeutic interventions, namely dialectical behavioral therapy, cognitive behavioral therapy, schema-focused therapy and manual-assisted cognitive therapy. All above stated treatments showed clinical beneficial effects, by reducing borderline personality disorder core pathology and associated general psychopathology, as well as by reducing the severity and frequency of self-harm behaviors, and by improving the overall social, interpersonal and global adjustment. Dialectical behavioral therapy and schema-focused therapy also caused a soaring remission rate of diagnostic borderline personality disorder criteria of 57% and 94%, respectively. Although there were differences between the psychotherapeutic interventions analysed in this review, all showed clinical benefits in the treatment of borderline personality disorder. Dialectical behavioral therapy and schema-focused therapy presented the strongest scientific data documenting their efficacy, but both interventions are integrative cognitive-behavioral therapies which deviate from the traditional cognitive-behavioral model. In summary, the available studies support cognitive-behavioral psychological treatments as an efficacious intervention in borderline personality disorder. However, the existing scientific literature on this topic is still scarce and there is need for more studies, with higher methodological rigor, that should validate these results.
Outcomes of borderline rheumatic heart disease: A prospective cohort study.
Bertaina, Geneviève; Rouchon, Bernard; Huon, Bertrand; Guillot, Nina; Robillard, Corinne; Noël, Baptiste; Nadra, Marie; Tribouilloy, Christophe; Marijon, Eloi; Jouven, Xavier; Mirabel, Mariana
2017-02-01
The advent of systematic screening for rheumatic heart disease (RHD) by echocardiography in endemic regions has led to a new entity: borderline RHD. The pathogenicity and natural history of borderline RHD needs to be addressed. The aim of this study was to assess the outcomes of children detected by echocardiography as having borderline RHD. Schoolchildren in 4th grade (i.e., aged 9-10years) who were prospectively echo-screened for RHD (2012-2014) in Nouméa, New Caledonia, were asked to participate. Children with borderline RHD according to consistent independent review by two cardiologists were included and followed-up in 2015. Among the 8684 schoolchildren screened, 49 were diagnosed with borderline RHD according to the Cardiologist clinically involved in the child's management plan. After independent review by two cardiologists, 25 children were consistently diagnosed with borderline RHD and included in the follow-up study. Overall, inter-observer agreement was moderate with diagnostic kappa values of 0.63 (95% CI 0.45-0.78). After a median follow-up of 23months (IQR (20.5-33.0), 15 children (60.0%) had stability of valvular lesions, 8 (32.0%) had normal findings according to the WHF criteria. Two children (8.0%) had definite RHD on the follow-up echocardiogram, but no clinical events or audible pathological murmur during the study period. No factor could be identified as prognostic of either stability or progression. Borderline RHD diagnosed by systematic screening in high-risk populations remains mostly unchanged at 2years follow-up. Diagnosis of borderline RHD may require two reviewers for consistency. Copyright © 2016. Published by Elsevier Ireland Ltd.
Zanarini, Mary C.; Frankenburg, Frances R.; Reich, D. Bradford; Fitzmaurice, Garrett
2012-01-01
Objective The first purpose of this study was to determine time-to-attainment of symptomatic remissions and recoveries of 2, 4, 6, and 8 years duration for those with borderline personality disorder and comparison subjects with other personality disorders; the second was to determine the stability of these outcomes. Method 290 inpatients meeting both Revised Diagnostic Interview for Borderlines and DSM-III-R criteria for borderline personality disorder and 72 axis II comparison subjects were assessed during their index admission using a series of semistructured interviews. The same instruments were readministered at eight contiguous two-year time periods. Results Borderline patients were significantly slower to achieve remission or recovery (which involved good social and vocational functioning as well as symptomatic remission) than axis II comparison subjects. However, those in both study groups ultimately achieved about the same high rates of remission (borderline patients: 78–99%; axis II comparison subjects: 97–99%) but not recovery (40–60% vs. 75–85%) by the time of the 16-year follow-up. In contrast, symptomatic recurrence (10–36% vs. 4–7%) and loss of recovery (20–44% vs. 9–28%) occurred more rapidly and at substantially higher rates among borderline patients than axis II comparison subjects. Conclusions Taken together, the results of this study suggest that sustained symptomatic remission is substantially more common than sustained recovery from borderline personality disorder. They also suggest that sustained remissions and recoveries are substantially more difficult for borderline patients to attain and maintain than those with other forms of personality disorder. PMID:22737693
[Emotional and impulsive dimensions in bipolar disorder and borderline personality disorder].
Leblanc, A; Jarroir, M; Vorspan, F; Bellivier, F; Leveillee, S; Romo, L
2017-05-01
Studies have shown that patients with borderline personality disorder are often misdiagnosed to have bipolar disorder and conversely. Indeed, a number of characteristics common to both disorders could explain this problem: emotional instability as well as impulsivity represent confounding factors and contribute to the risk of misdiagnosis. However, it appears that these characteristics manifest themselves in different ways according to the pathology. The aim of the study is to show differences between affective lability, emotional intensity and impulsivity dimensions. The clinical aim is to refine bipolar disorder and borderline personality disorder diagnosis, to improve psychological care for these patients in the long-term. We compared the emotional and impulsive dimensions in two groups of patients: a group of 21 patients with bipolar disorder and a group of 19 patients with borderline personality disorder. Tools: ALS, a self-report questionnaire to evaluate affective lability, AIM, a self-report questionnaire to see affective intensity, and UPPS, a self-report questionnaire to measure impulsivity according to several dimensions. The results indicate that borderline patients scored significantly higher than bipolar patients at the ALS and AIM scales. Regarding the UPPS, borderline patients scored significantly higher than bipolar patients for the dimensions "lack of premeditation" and "lack of perseverance"; however, bipolar patients had significantly higher scores than borderline patients for the dimension "negative emergency". This study shows that bipolar disorder and borderline personality can be differentiated thanks to emotional dimensions as well as different dimensions of impulsivity: borderline patients appear to have an affective lability and intensity more important than bipolar patients; it also appears that impulsivity manifests itself differently according to the disorder. Copyright © 2016 L'Encéphale, Paris. Published by Elsevier Masson SAS. All rights reserved.
Risk of borderline ovarian tumors among women with benign ovarian tumors: A cohort study.
Guleria, Sonia; Jensen, Allan; Kjær, Susanne K
2018-01-01
A growing number of studies suggest that some ovarian cancers can arise from benign and borderline ovarian tumors. However, studies on the association between benign and borderline ovarian tumors are lacking. We studied the overall- and histotype-specific risk of borderline ovarian tumors among women with a benign ovarian tumor. This nationwide cohort study included all Danish women diagnosed with a benign ovarian tumor (n=139,466) during 1978-2012. The cohort was linked to the Danish Pathology Data Bank and standardized incidence ratios (SIR) with 95% confidence intervals (CI) were calculated. Women with benign ovarian tumors had increased risks for subsequent borderline ovarian tumors (SIR 1.62, 95% CI 1.43-1.82), and this applied to both serous (SIR 1.69, 95% CI 1.39-2.03) and mucinous (SIR 1.75, 95% CI 1.45-2.10) histotypes of borderline ovarian tumors. The risk for borderline ovarian tumors was primarily increased for women diagnosed with a benign ovarian tumor before 40years of age. The risk remained increased up to 9years after a benign ovarian tumor diagnosis. Finally, the associations did not change markedly when analyzed for the different histotypes of benign (solid and cystic tumors) and borderline (serous and mucinous tumors) ovarian tumors. Women with benign ovarian tumors have a long-term increased risk for borderline ovarian tumors. However, as all associations in this study were only adjusted for age and calendar period of diagnosis, more studies that are able to adjust for additional potential confounding variables are required to further understand these associations. Copyright © 2017 Elsevier Inc. All rights reserved.
Outcalt, Jared; Dimaggio, Giancarlo; Popolo, Raffaele; Buck, Kelly; Chaudoin-Patzoldt, Kelly A; Kukla, Marina; Olesek, Kyle L; Lysaker, Paul H
2016-01-01
Borderline personality disorder traits have been observed to be linked with both insecure attachment styles as well as deficits in mentalizing and metacognition. Less is known, however, about how attachment style does or does not interact with deficits in mentalizing and metacognition to create, sustain, or influence levels of borderline personality disorder traits. In this study, we examined the hypothesis that metacognitive mastery, which is the ability to use knowledge about mental states of self and others to cope with distress and solve social problems, moderates the relationship of anxious attachment style with the severity of borderline personality disorder traits. Concurrent assessments were gathered of metacognitive mastery using the Metacognitive Assessment Scale Abbreviated, anxious attachment style using the Experiences of in Close Relationships Scale, and borderline personality disorder traits using the Structured Clinical Interview for DSM-IV Axis II Disorders. Participants were 59 adults in an early phase of recovery from substance use disorders in a residential setting. Multiple regression revealed that metacognitive mastery moderated the relationship of anxious attachment style with the number of borderline personality disorder traits. A median split of the anxious attachment and metacognitive mastery scores was performed yielding 4 groups. An analysis of covariance revealed that participants with higher levels of anxious attachment and poorer metacognitive mastery had more borderline personality disorder traits did than the other groups after controlling for levels of psychopathology. Insecure attachment may be associated with higher number of borderline personality disorder traits in the presence of deficits in metacognitive mastery. Patients with substance use and borderline personality disorder traits may benefit from treatment which addresses metacognitive mastery. Published by Elsevier Inc.
40 CFR 63.176 - Quality improvement program for pumps.
Code of Federal Regulations, 2010 CFR
2010-07-01
... such as discharge pressure, temperature, flow rate, corrosivity, and annual operating hours. (iii) The... classes, of pumps as needed to distinguish among operating conditions and services associated with poorer...
Yamazaki, K; Mori, T; Tomioka, J; Litwak, P; Antaki, J F; Tagusari, O; Koyanagi, H; Griffith, B P; Kormos, R L
1997-01-01
A critical issue facing the development of an implantable, rotary blood pump is the maintenance of an effective seal at the rotating shaft. Mechanical seals are the most versatile type of seal in wide industrial applications. However, in a rotary blood pump, typical seal life is much shorter than required for chronic support. Seal failure is related to adhesion and aggregation of heat denatured blood proteins that diffuse into the lubricating film between seal faces. Among the blood proteins, fibrinogen plays an important role due to its strong propensity for adhesion and low transition temperature (approximately 50 degrees C). Once exposed to temperature exceeding 50 degrees C, fibrinogen molecules fuse together by multi-attachment between heat denatured D-domains. This quasi-polymerized fibrin increases the frictional heat, which proliferates the process into seal failure. If the temperature of the seal faces is maintained well below 50 degrees C, a mechanical seal would not fail in blood. Based on this "Cool-Seal" concept, we developed a miniature mechanical seal made of highly thermally conductive material (SiC), combined with a recirculating purge system. A large supply of purge fluid is recirculated behind the seal face to augment convective heat transfer to maintain the seal temperature below 40 degrees C. It also cools all heat generating pump parts (motor coil, bearing, seal). The purge consumption has been optimized to virtually nil (< 0.5 cc/day). An ultrafiltration unit integrated in the recirculating purge system continuously purifies and sterilizes the purge fluid for more than 5 months without filter change. The seal system has now been incorporated into our intraventricular axial flow blood pump (IVAP) and newly designed centrifugal pump. Ongoing in vivo evaluation of these systems has demonstrated good seal integrity for more than 160 days. The Cool-Seal system can be applied to any type of rotary blood pump (axial, diagonal, centrifugal, etc.) and offers a practical solution to the shaft seal problem and heat related complications, which currently limit the use of implantable rotary blood pumps.
Parental qualities as perceived by borderline personality disorders.
Goldberg, R L; Mann, L S; Wise, T N; Segall, E A
1985-01-01
This study explores the contribution of parental qualities to the borderline personality disorder. The Parental Bonding Inventory is used to compare four parental qualities (caring mother, caring father, overprotective father, and overprotective mother) across three groups (borderline personality disorders, assorted psychiatric controls and normal controls). The major finding was that the borderline patients perceived their parents to be significantly less caring and more overprotective than both the psychiatric control or nonclinical control groups. This study was verified previous reports that patients diagnosed with an affective illness (in either the borderline group or psychiatric control group) reported no significant differences on the inventory. Pinpointing parental characteristics which antecede mental disorders may be an important first step in devising primary preventive interventions for adult disorders.
Parenting Children With Borderline Intellectual Functioning: A Unique Risk Population
Fenning, Rachel M.; Baker, Jason K.; Baker, Bruce L.; Crnic, Keith A.
2009-01-01
Parenting was examined among families of children with borderline intelligence in comparison to families of typically developing children and children with developmental delays. Parenting data were obtained at child age 5 via naturalistic home observation. Mothers of children with borderline intelligence exhibited less positive and less sensitive parenting behaviors than did other mothers and were least likely to display a style of positive engagement. Children with borderline intelligence were not observed to be more behaviorally problematic than other children; however, their mothers perceived more externalizing symptoms than did mothers of typically developing children. Findings suggest the importance of mothers’ explanatory models for child difficulties and highlight children with borderline intelligence as uniquely at risk for poor parenting. PMID:17295551
High Temperature Polymer Film Dielectrics for Aerospace Power Conditioning Capacitor Applications
2008-10-01
a temperature controller as well as a vacuum controller. A vacuum of əTorr is achieved with a combination of a turbo pump and a scroll pump system...the addition of a non- solvent such as de-ionized, distilled water. The films were dried at ∼0.1 Torr vacuum in an oven for several days at 65–75 ◦C
Raynal, Patrick; Chabrol, Henri
2016-09-01
The aim of the study was to examine the association of schizotypal and borderline personality traits to cannabis use. Participants were 476 college students (95 males; 381 females; mean age of males=21; mean age of females=20.7) who completed self-report questionnaires assessing cannabis use, schizotypal and borderline personality traits. Problematic cannabis use, depressive symptoms, borderline and schizotypal traits were significantly inter-correlated. A logistic regression analysis showed that only borderline traits contributed significantly to cannabis use in the total sample. A multiple regression analysis showed that only schizotypal traits were positively and uniquely associated to problematic cannabis use symptoms among users. These results may imply that schizotypal traits are not a risk factor for initiating use, but may facilitate the development of problematic use symptoms among users. This study showed the necessity of taking into account schizotypal traits when exploring the relationships between depressive symptoms, borderline traits and cannabis use. Copyright © 2016 Elsevier Ltd. All rights reserved.
Prognostic indicators in ovarian serous borderline tumours.
Malpica, Anais; Longacre, Teri A
2018-02-01
There have been great strides in our understanding of the serous group of borderline and malignant pelvic epithelial neoplasms in the past decade. While most serous borderline tumours have a favourable prognosis, recurrences and progression to carcinoma occur, often following a protracted clinical course. Clinical and pathological risk factors tend to co-vary, but the presence and type of extraovarian disease is the most important predictor for progression. Progression usually takes the form of low-grade serous carcinoma, although transformation to high-grade carcinoma is occasionally seen. A serous borderline - low-grade serous carcinoma pathway analogous to neoplastic transformation pathways seen in other organ systems has been proposed, based on global gene expression profiling, shared mutations in KRAS or BRAF, and in most cases, the presence of serous borderline tumour in de novo low-grade serous carcinoma. This discussion focuses on the key prognostic factors that predispose to disease progression and/or transformation to carcinoma in serous borderline tumours. Published by Elsevier B.V.
Hecht, Kathryn F.; Cicchetti, Dante; Rogosch, Fred A.; Crick, Nicki
2014-01-01
Child maltreatment has been established as a risk factor for borderline personality disorder (BPD), yet few studies consider how maltreatment influences the development of BPD features through childhood and adolescence. Subtype, developmental timing and chronicity of child maltreatment were examined as factors in the development of borderline personality features in childhood. Children (M age = 11.30, SD = 0.94), including 314 maltreated and 285 nonmaltreated children from comparable low socioeconomic backgrounds, provided self-reports of developmentally salient borderline personality traits. Maltreated children had higher overall borderline feature scores, higher scores on each individual subscale and were more likely to be identified as at high risk for development of BPD through raised scores on all 4 subscales. Chronicity of maltreatment predicted higher overall borderline feature scores and patterns of onset and recency of maltreatment significantly predicted whether a participant would meet criteria for the high-risk group. Implications of findings and recommendations for intervention are discussed. PMID:25047300
Hecht, Kathryn F; Cicchetti, Dante; Rogosch, Fred A; Crick, Nicki R
2014-08-01
Child maltreatment has been established as a risk factor for borderline personality disorder (BPD), yet few studies consider how maltreatment influences the development of BPD features through childhood and adolescence. Subtype, developmental timing, and chronicity of child maltreatment were examined as factors in the development of borderline personality features in childhood. Children (M age = 11.30, SD = 0.94), including 314 maltreated and 285 nonmaltreated children from comparable low socioeconomic backgrounds, provided self-reports of developmentally salient borderline personality traits. Maltreated children had higher overall borderline feature scores, had higher scores on each individual subscale, and were more likely to be identified as at high risk for development of BPD through raised scores on all four subscales. Chronicity of maltreatment predicted higher overall borderline feature scores, and patterns of onset and recency of maltreatment significantly predicted whether a participant would meet criteria for the high-risk group. Implications of findings and recommendations for intervention are discussed.
Nouwens, Peter J G; Lucas, Rosanne; Smulders, Nienke B M; Embregts, Petri J C M; van Nieuwenhuizen, Chijs
2017-07-17
Persons with mild intellectual disability or borderline intellectual functioning are often studied as a single group with similar characteristics. However, there are indications that differences exist within this population. Therefore, the aim of this study was to identify classes of persons with mild intellectual disability or borderline intellectual functioning and to examine whether these classes are related to individual and/or environmental characteristics. Latent class analysis was performed using file data of 250 eligible participants with a mean age of 26.1 (SD 13.8, range 3-70) years. Five distinct classes of persons with mild intellectual disability or borderline intellectual functioning were found. These classes significantly differed in individual and environmental characteristics. For example, persons with a mild intellectual disability experienced fewer problems than those with borderline intellectual disability. The identification of five classes implies that a differentiated approach is required towards persons with mild intellectual disability or borderline intellectual functioning.
Cvetanovich, Gregory L; Levy, David M; Weber, Alexander E; Kuhns, Benjamin D; Mather, Richard C; Salata, Michael J; Nho, Shane J
2017-07-01
The literature contains conflicting reports regarding whether outcomes of hip arthroscopic surgery for patients with borderline dysplasia are inferior to outcomes in patients with normal acetabular coverage. To assess differences in the outcomes of hip arthroscopic surgery for femoroacetabular impingement (FAI) in groups of patients with borderline dysplasia and normal coverage. Cohort study; Level of evidence, 3. A registry of consecutive patients who had undergone primary hip arthroscopic surgery with capsular plication for FAI between January 2012 and January 2014 were divided based on the preoperative lateral center-edge angle (LCEA) into 2 distinct groups: (1) borderline dysplasia (LCEA 18°-25°) and (2) normal acetabular coverage (LCEA 25.1°-40°). There were 36 patients in the borderline dysplastic group and 312 patients in the normal coverage group. The primary outcome measure was the Hip Outcome Score-Activities of Daily Living (HOS-ADL) at a minimum of 2 years postoperatively. Secondary outcome measures included the HOS-Sports and modified Harris Hip Score (mHHS). The mean preoperative LCEA differed significantly between groups (23.4° ± 1.5° for borderline dysplastic, 32.5° ± 3.8° for normal coverage; P < .001). The borderline dysplastic group had a higher percentage of female patients than the normal coverage group (27/36 [75%] vs 177/312 [57%], respectively; P = .048). There were no differences in other preoperative demographics and radiographic parameters. At a minimum 2 years after hip arthroscopic surgery (mean follow-up, 2.6 ± 0.6 years), both groups demonstrated significant improvements in all patient-reported outcome scores ( P < .001 in all cases). There were no significant differences between the borderline dysplastic and normal coverage groups in final outcome scores, score improvements, or percentage of patients experiencing clinically significant improvements. One patient in the borderline dysplastic group (3%) underwent revision hip arthroscopic surgery, and none underwent total hip arthroplasty during the follow-up period. There were no differences between the borderline dysplastic and normal coverage groups with regard to subsequent surgery. Female patients in the borderline dysplastic group had greater improvements in the mean HOS-ADL (25.9 ± 16.3 vs 10.8 ± 18.5, respectively; P = .05) and mHHS (27.9 ± 12.9 vs 8.1 ± 19.0, respectively; P = .005) compared with male patients in the borderline dysplastic group, but male and female patients did not differ in outcomes for the normal coverage group. Patients who underwent hip arthroscopic surgery for FAI with capsular plication experienced significant clinical improvements with low rates of subsequent surgery, regardless of whether their acetabulum had borderline dysplasia or normal coverage.
Electromagnetic Pumps for Liquid Metal-Fed Electric Thrusters
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Markusic, Thomas E.
2007-01-01
Prototype designs of two separate pumps for use in electric propulsion systems with liquid lithium and bismuth propellants are presented. Both pumps are required to operate at elevated temperatures, and the lithium pump must additionally withstand the corrosive nature of the propellant. Compatibility of the pump materials and seals with lithium and bismuth were demonstrated through proof-of-concept experiments followed by post-experiment visual inspections. The pressure rise produced by the bismuth pump was found to be linear with input current and ranged from 0-9 kPa for corresponding input current levels of 0-30 A, showing good quantitative agreement with theoretical analysis.
Newswanger, Brett; Ammons, Steve; Phadnis, Neelima; Ward, W. Kenneth; Castle, Jessica; Campbell, Robert W.
2015-01-01
Background: Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. Methods: This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Results: Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as “in use” stability and compatibility in an Insulet’s OmniPod® infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. Conclusions: This nonaqueous glucagon formulation is suitable for further clinical development in pump systems. PMID:25550410
NASA Astrophysics Data System (ADS)
Kwiatkowski, Jacek; Zendzian, Waldemar; Jabczynski, Jan K.
2016-12-01
A detailed study of a Tm:YAP laser in continuous-wave (CW), single-pass end-pumped by a 793 nm diode laser is presented. The laser based on c-cut 3 at. % Tm:YAP crystal was experimentally examined and presented in the dependence on transmittance and radius of curvature of output coupling mirrors. A detailed spectral analysis was presented. The influence of a heat-sink cooling water temperature on the laser performance was studied. At room temperature, for an output coupling transmission of 19.5%, the maximum CW output power of 4.53 W was achieved, corresponding to a slope efficiency of 41.5% and an optical-to-optical conversion efficiency of 25.7% with respect to the incident pump power, respectively. We have shown that the output spectrum at a certain wavelength (e.g. 1940 nm) for a given pump power can be realized via the change of resonator parameters (OC transmittance, mode size).
Newswanger, Brett; Ammons, Steve; Phadnis, Neelima; Ward, W Kenneth; Castle, Jessica; Campbell, Robert W; Prestrelski, Steven J
2015-01-01
Despite a vigorous research effort, to date, the development of systems that achieve glucagon stability in aqueous formulations (without reconstitution) has failed to produce any clinical candidates. We have developed a novel, nonaqueous glucagon formulation based on a biocompatible pharmaceutical solvent, dimethyl sulfoxide, which demonstrates excellent physical and chemical stability at relatively high concentrations and at high temperatures. This article reports the development of a novel, biocompatible, nonaqueous native human glucagon formulation for potential use in subcutaneous infusion pump systems. Data are presented that demonstrate physical and chemical stability under presumed storage conditions (>2 years at room temperature) as well as "in use" stability and compatibility in an Insulet's OmniPod(®) infusion pump. Also presented are results of a skin irritation study in a rabbit model and pharmacokinetics/pharmacodynamics data following pump administration of glucagon in a diabetic swine model. This nonaqueous glucagon formulation is suitable for further clinical development in pump systems. © 2015 Diabetes Technology Society.
A Superfluid Pulse Tube Refrigerator Without Moving Parts for Sub-Kelvin Cooling
NASA Technical Reports Server (NTRS)
Miller, Franklin K.
2012-01-01
A report describes a pulse tube refrigerator that uses a mixture of He-3 and superfluid He-4 to cool to temperatures below 300 mK, while rejecting heat at temperatures up to 1.7 K. The refrigerator is driven by a novel thermodynamically reversible pump that is capable of pumping the He-3 He-4 mixture without the need for moving parts. The refrigerator consists of a reversible thermal magnetic pump module, two warm heat exchangers, a recuperative heat exchanger, two cold heat exchangers, two pulse tubes, and an orifice. It is two superfluid pulse tubes that run 180 out of phase. All components of this machine except the reversible thermal pump have been demonstrated at least as proof-of-concept physical models in previous superfluid Stirling cycle machines. The pump consists of two canisters packed with pieces of gadolinium gallium garnet (GGG). The canisters are connected by a superleak (a porous piece of VYCOR glass). A superconducting magnetic coil surrounds each of the canisters.
Borderline amniotic fluid index and perinatal outcomes in the uncomplicated term pregnancy.
Choi, Soo Ran
2016-01-01
To determine perinatal outcomes in uncomplicated term pregnancies with a borderline amniotic fluid index (AFI). A retrospective review was conducted of uncomplicated singleton pregnancies at term (>37 weeks). Borderline and normal AFI were defined as 5.1 ≤ AFI ≤ 8.0 cm and 8.1 ≤ AFI ≤ 24 cm, respectively. Adverse perinatal outcomes, cesarean delivery for non-reassuring fetal heart rate testing, meconium-stained amniotic fluid, a 5-min Apgar score of <7, admission to the neonatal intensive care unit (NICU), and whether the neonate was small for gestational age were compared between the borderline and normal AFI groups. Borderline AFI was not significantly associated with cesarean delivery for non-reassuring fetal heart rate testing (p = 0.513), meconium-stained amniotic fluid (p = 0.641), admission to the NICU (p = 0.368), or a 5-min Apgar score of <7 (p = 1.00). However, the number of neonates who were small for gestational age (p = 0.021) and rates of induction of labor (p < 0.001) were significantly higher in the borderline group. Multiple logistic regression analysis showed that borderline AFI was not associated with cesarean delivery for non-reassuring fetal heart rate testing (odds ratio [OR] = 0.72, 95% confidence interval [CI] 0.27-1.91, p = 0.52). In uncomplicated term pregnancies, a borderline AFI does not increase the risk of adverse perinatal outcomes.
Beck, Emma; Sharp, Carla; Poulsen, Stig; Bo, Sune; Pedersen, Jesper; Simonsen, Erik
2017-01-01
Insecure attachment is a precursor and correlate of borderline personality disorder. According to the mentalization-based theory of borderline personality disorder, the presence of insecure attachment derails the development of the capacity to mentalize, potentially resulting in borderline pathology. While one prior study found support for this notion in adolescents, it neglected a focus on peer attachment. Separation from primary caregivers and formation of stronger bonds to peers are key developmental achievements during adolescence and peer attachment warrants attention as a separate concept. In a cross-sectional study, female outpatients (M age 15.78=, SD = 1.04) who fulfilled DSM-5 criteria for BPD ( N = 106) or met at least 4 BPD criteria ( N = 4) completed self-reports on attachment to parents and peers, mentalizing capacity (reflective function) and borderline personality features. Our findings suggest that in a simple mediational model, mentalizing capacity mediated the relation between attachment to peers and borderline features. In the case of attachment to parents, the mediational model was not significant. The current study is the first to evaluate this mediational model with parent and peer attachment as separate concepts and the first to do so in a sample of adolescents who meet full or sub-threshold criteria for borderline personality disorder. Findings incrementally support that mentalizing capacity and attachment insecurity, also in relation to peers, are important concepts in theoretical approaches to the development of borderline personality disorder in adolescence. Clinical implications are discussed.
Perinatal outcomes in uncomplicated late preterm pregnancies with borderline oligohydramnios.
Sahin, Erdem; Madendag, Yusuf; Tayyar, Ahter Tanay; Sahin, Mefkure Eraslan; Col Madendag, Ilknur; Acmaz, Gokhan; Unsal, Deniz; Senol, Vesile
2017-08-16
The purpose of this study is to determine the adverse perinatal outcomes in uncomplicated late preterm pregnancies with borderline oligohydramnios. A total of 430 pregnant women with an uncomplicated singleton pregnancy at a gestational age of 34 + 0-36 + 6 weeks were included. Borderline oligohydramnios was defined as an amniotic fluid index (AFI) of 5.1-8 cm, which was measured using the four-quadrant technique. Adverse perinatal outcomes were compared between the borderline and normal AFI groups. Approximately 107 of the 430 pregnant women were borderline AFI, and 323 were normal AFI. The demographic and obstetric characteristics were similar in both groups. Delivery <37 weeks, cesarean delivery for non-reassuring fetal heart-rate testing, meconium-stained amniotic fluid, Apgar 5 min <7, transient tachypnea of the newborn, respiratory distress syndrome, neonatal intensive care unit, and hyperbilirubinemia were not statistically different between the groups (p = .054, p = .134, p = .749, p = 0.858, p = .703, p = .320, p = .185, and p = .996, respectively). Although gestational age was full-term, induction of labor rates were significantly higher in the borderline AFI group (p = .040). In addition, fetal renal artery pulsatility index pulsatility index (PI) was significantly lower in the borderline AFI group than in the normal AFI group (p = .014). Our results indicated that borderline AFI was not a risk for adverse perinatal outcomes in uncomplicated, late preterm pregnancies.
Quek, Jeremy; Newman, Louise K; Bennett, Clair; Gordon, Michael S; Saeedi, Naysun; Melvin, Glenn A
2017-10-01
Deficits in mentalizing, particularly within the context of attachment relationships i.e., reflective function (RF), are posited to result from childhood maltreatment and to influence the development of borderline personality disorder (BPD). Whilst a mentalization-based model of BPD provides a theoretical explanation, direct empirical support for this model, in linking childhood maltreatment to borderline pathology remains limited. This study examined the interrrelationships between childhood maltreatment, RF, and borderline pathology in a mixed adolescent sample, consisting of adolescents with BPD (n=26) and a group of non-clinical adolescents (n=25). With the aim of directly testing the mentalization-based model of BPD, we additionally investigated the influence of each form of childhood maltreatment within this developmental pathway. Self-report data supported the hypothesized indirect effect of childhood maltreatment on elevated borderline pathology through lowered RF in adolescents. Both emotional abuse and emotional neglect were found to indirectly influence borderline pathology through adolescent RF, however, only emotional abuse indirectly influenced borderline pathology through RF, after all other maltreatment types were controlled for. Findings support the promotion of mentalization, within attachment-related contexts, as an intervention target for adolescents with borderline pathology and as a potential target of prevention for at-risk children and adolescents with histories of childhood maltreatment, especially emotional abuse. Future research should delineate other underlying mechanisms, independent of RF, which may also link the influence of childhood maltreatment, and in particular, emotional abuse, to BPD. Copyright © 2017 Elsevier Ltd. All rights reserved.
Zimmerman, Mark; Ellison, William; Morgan, Theresa A; Young, Diane; Chelminski, Iwona; Dalrymple, Kristy
2015-10-01
The morbidity associated with bipolar disorder is, in part, responsible for repeated calls for improved detection and recognition. No such commentary exists for the improved detection of borderline personality disorder. Clinical experience suggests that it is as disabling as bipolar disorder, but no study has directly compared the two disorders. To compare the levels of psychosocial morbidity in patients with bipolar disorder and borderline personality disorder. Patients were assessed with semi-structured interviews. We compared 307 patients with DSM-IV borderline personality disorder but without bipolar disorder and 236 patients with bipolar disorder but without borderline personality disorder. The patients with borderline personality disorder less frequently were college graduates, were diagnosed with more comorbid disorders, more frequently had a history of substance use disorder, reported more suicidal ideation at the time of the evaluation, more frequently had attempted suicide, reported poorer social functioning and were rated lower on the Global Assessment of Functioning. There was no difference between the two patient groups in history of admission to psychiatric hospital or time missed from work during the past 5 years. The level of psychosocial morbidity associated with borderline personality disorder was as great as (or greater than) that experienced by patients with bipolar disorder. From a public health perspective, efforts to improve the detection and treatment of borderline personality disorder might be as important as efforts to improve the recognition and treatment of bipolar disorder. © The Royal College of Psychiatrists 2015.
Belli, Hasan; Ural, Cenk; Akbudak, Mahir
2012-01-01
In this article, it is aimed to review the efficacies of mood stabilizers and atypical antipsychotics, which are used commonly in psychopharmacological treatments of bipolar and borderline personality disorders. In this context, common phenomenology between borderline personality and bipolar disorders and differential features of clinical diagnosis will be reviewed in line with the literature. Both disorders can demonstrate common features in the diagnostic aspect, and can overlap phenomenologically. Concomitance rate of both disorders is quite high. In order to differentiate these two disorders from each other, quality of mood fluctuations, impulsivity types and linear progression of disorders should be carefully considered. There are various studies in mood stabilizer use, like lithium, carbamazepine, oxcarbazepine, sodium valproate and lamotrigine, in the treatment of borderline personality disorder. Moreover, there are also studies, which have revealed efficacies of risperidone, olanzapine and quetiapine as atypical antipsychotics. It is not easy to differentiate borderline personality disorder from the bipolar disorders. An intensively careful evaluation should be performed. This differentiation may be helpful also for the treatment. There are many studies about efficacy of valproate and lamotrigine in treatment of borderline personality disorder. However, findings related to other mood stabilizers are inadequate. Olanzapine and quetiapine are reported to be more effective among atypical antipsychotics. No drug is approved for the treatment of borderline personality disorder by the entitled authorities, yet. Psychotherapeutic approaches have preserved their significant places in treatment of borderline personality disorder. Moreover, symptom based approach is recommended in use of mood stabilizers and atypical antipsychotics. PMID:23024731
Flow tube used to cool solar-pumped laser
NASA Technical Reports Server (NTRS)
1968-01-01
A flow tube has been designed and constructed to provide two major functions in the application of a laser beam for transmission of both sound and video. It maintains the YAG laser at the proper operating temperature of 300 degrees K under solar pumping conditions, and it serves as a pump cavity for the laser crystal.
Experimental investigation of biomimetic self-pumping and self-adaptive transpiration cooling.
Jiang, Pei-Xue; Huang, Gan; Zhu, Yinhai; Xu, Ruina; Liao, Zhiyuan; Lu, Taojie
2017-09-01
Transpiration cooling is an effective way to protect high heat flux walls. However, the pumps for the transpiration cooling system make the system more complex and increase the load, which is a huge challenge for practical applications. A biomimetic self-pumping transpiration cooling system was developed inspired by the process of trees transpiration that has no pumps. An experimental investigation showed that the water coolant automatically flowed from the water tank to the hot surface with a height difference of 80 mm without any pumps. A self-adaptive transpiration cooling system was then developed based on this mechanism. The system effectively cooled the hot surface with the surface temperature kept to about 373 K when the heating flame temperature was 1639 K and the heat flux was about 0.42 MW m -2 . The cooling efficiency reached 94.5%. The coolant mass flow rate adaptively increased with increasing flame heat flux from 0.24 MW m -2 to 0.42 MW m -2 while the cooled surface temperature stayed around 373 K. Schlieren pictures showed a protective steam layer on the hot surface which blocked the flame heat flux to the hot surface. The protective steam layer thickness also increased with increasing heat flux.
Benson, S.M.; Janik, C.J.; Long, D.C.; Solbau, R.D.; Lienau, P.J.
1984-01-01
A seven-week pumping and injection tests in the geothermal aquifer at Klamath Falls, Oregon, in 1983 provided new information on hydraulic properties of the aquifer. The Open-File Data Report on the tests includes graphs of water levels measured in 50 wells, temperature measurement in 17 wells , daily air-temperatures in relation to discharge of thermal water from more than 70 pumped and artesian wells, tables of monthly mean air temperatures and estimates of discharges of thermal water during a normal year, and tables of chemical and isotopic analyses on samples from 12 wells. The water-level measurements reflect the effects of pumping, injection, and recovery over about 1.7 square miles of the hot-well area of Klamath Falls. The pumped well, City Well No 1, and the injection well at the Klamath County Museum are components of a proposed District Heating Plan. The study was funded principally under contracts from the U.S. Department of Energy to the Lawrence Berkeley Laboratory, Stanford University, and the Oregon Institute of Technology, with coordination and chemical sampling provided under the Geothermal Research Program, U.S. Geological Survey. Support was received from the City of Klamath Falls, Klamath County Chamber of Commerce, Citizens for Responsible Geothermal Development, and many citizen volunteers. (USGS)
NASA Astrophysics Data System (ADS)
Newton, Hayley; Walkup, Laura L.; Whiting, Nicholas; West, Linda; Carriere, James; Havermeyer, Frank; Ho, Lawrence; Morris, Peter; Goodson, Boyd M.; Barlow, Michael J.
2014-05-01
Spin-exchange optical pumping (SEOP) has been widely used to produce enhancements in nuclear spin polarisation for hyperpolarised noble gases. However, some key fundamental physical processes underlying SEOP remain poorly understood, particularly in regards to how pump laser energy absorbed during SEOP is thermalised, distributed and dissipated. This study uses in situ ultra-low frequency Raman spectroscopy to probe rotational temperatures of nitrogen buffer gas during optical pumping under conditions of high resonant laser flux and binary Xe/N2 gas mixtures. We compare two methods of collecting the Raman scattering signal from the SEOP cell: a conventional orthogonal arrangement combining intrinsic spatial filtering with the utilisation of the internal baffles of the Raman spectrometer, eliminating probe laser light and Rayleigh scattering, versus a new in-line modular design that uses ultra-narrowband notch filters to remove such unwanted contributions. We report a ~23-fold improvement in detection sensitivity using the in-line module, which leads to faster data acquisition and more accurate real-time monitoring of energy transport processes during optical pumping. The utility of this approach is demonstrated via measurements of the local internal gas temperature (which can greatly exceed the externally measured temperature) as a function of incident laser power and position within the cell.
Impact on Water Heater Performance of Heating Methods that Promote Tank Temperature Stratification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gluesenkamp, Kyle R; BushPE, John D
2016-01-01
During heating of a water heater tank, the vertical temperature stratification of the water can be increased or decreased, depending on the method of heating. Methods that increase stratification during heating include (1) removing cold water from the tank bottom, heating it, and re-introducing it to the tank top at relatively low flow rate, (2) using a heat exchanger wrapped around the tank, through which heating fluid (with finite specific heat) flows from top to bottom, and (3) using an immersed heat element that is relatively high in the tank. Using such methods allows for improved heat pump water heatermore » (HPWH) cycle efficiencies when the heat pump can take advantage of the lower temperatures that exist lower in the tank, and accommodate the resulting glide. Transcritical cycles are especially well-suited to capitalize on this opportunity, and other HPWH configurations (that have been proposed elsewhere) may benefit as well. This work provides several stratification categories of heat pump water heater tank configurations relevant to their stratification potential. To illustrate key differences among categories, it also compiles available experimental data for (a) single pass pumped flow, (b) multi-pass pumped flow, and (c) top-down wrapped tank with transcritical refrigerant.« less
The Borderline Personality--An Adlerian Overview.
ERIC Educational Resources Information Center
Rattner, Leo
The person with a borderline personality is considered to be neither neurotic nor psychotic, but to exist somewhere in between these two diagnostic categories. Psychoanalytic theorists who have researched the phenomenon of the borderline personality have shifted their emphasis away from Freud's instinct psychology and toward an ego psychology…
CW lasing of Ho in KLu(WO4)2 in-band pumped by a diode-pumped Tm:KLu(WO4)2 laser.
Mateos, Xavier; Jambunathan, Venkatesan; Pujol, Maria Cinta; Carvajal, Joan Josep; Díaz, Francesc; Aguiló, Magdalena; Griebner, Uwe; Petrov, Valentin
2010-09-27
We demonstrate continuous wave (CW) room temperature laser operation of the monoclinic Ho(3+)-doped KLu(WO(4))(2) crystal using a diode-pumped Tm(3+):KLu(WO(4))(2) laser for in-band pumping. The slope efficiency achieved amounts to ~55% with respect to the absorbed power and the maximum output power of 648 mW is generated at 2078 nm.
Transversely diode-pumped alkali metal vapour laser
DOE Office of Scientific and Technical Information (OSTI.GOV)
Parkhomenko, A I; Shalagin, A M
2015-09-30
We have studied theoretically the operation of a transversely diode-pumped alkali metal vapour laser. For the case of high-intensity laser radiation, we have obtained an analytical solution to a complex system of differential equations describing the laser. This solution allows one to exhaustively determine all the energy characteristics of the laser and to find optimal parameters of the working medium and pump radiation (temperature, buffer gas pressure, and intensity and width of the pump spectrum). (lasers)
Theoretical model and simulations for a cw exciplex pumped alkali laser.
Huang, Wei; Tan, Rongqing; Li, Zhiyong; Lu, Xiaochuan
2015-12-14
The Exciplex Pumped Alkali Laser (XPAL) system, which is similar to DPAL (Diode Pumped Alkali vapor Laser), has been demonstrated in mixtures of Cs vapor, Ar, with and without ethane. Unlike DPAL, it uses the broadband absorption blue satellite of the alkali D2 line, created by naturally occuring collision pairs. For example, Cs-Ar collision pairs have an absorption width which is as wide as the one of commercial semiconductor diode lasers. A continuous wave XPAL four-level theoretical model is presented in this paper. More factors are considered, such as the spectral dependence of pumped laser absorption for broadband pumping and the longitudinal population variation. Some intra-cavity details, such as longitudinal distributions of pumped laser and alkali laser, can also be solved well. The predictions of optical-to-optical efficiency as a function of temperature and pumped laser intensity are presented. The model predicts that there is an optimum value of temperature or pumped laser intensity. The analysis of the influence of cell length on optical-to-optical efficiency shows that a better performance can be achieved when using longer cell. The prediction of influence of Ar concentration and reflectivity of output coupler shows that higher optical-to-optical efficiency could be achieved if lower reflectivity of output coupler and higher Ar concentration are used. The optical-to-optical efficiency as high as 84% achieved by optimizing configuration with the pumped intensity of 5 × 10⁷ W/cm² presented shows that broadband pumped four-level XPAL system has a potential of high optical-to-optical efficiency.
Transient Analysis of a Magnetic Heat Pump
NASA Technical Reports Server (NTRS)
Schroeder, E. A.
1985-01-01
An experimental heat pump that uses a rare earth element as the refrigerant is modeled using NASTRAN. The refrigerant is a ferromagnetic metal whose temperature rises when a magnetic field is applied and falls when the magnetic field is removed. The heat pump is used as a refrigerator to remove heat from a reservoir and discharge it through a heat exchanger. In the NASTRAN model the components modeled are represented by one-dimensional ROD elements. Heat flow in the solids and fluid are analyzed. The problem is mildly nonlinear since the heat capacity of the refrigerant is temperature-dependent. One simulation run consists of a series of transient analyses, each representing one stroke of the heat pump. An auxiliary program was written that uses the results of one NASTRAN analysis to generate data for the next NASTRAN analysis.
Evaluation of a large capacity heat pump concept for active cooling of hypersonic aircraft structure
NASA Technical Reports Server (NTRS)
Pagel, L. L.; Herring, R. L.
1978-01-01
Results of engineering analyses assessing the conceptual feasibility of a large capacity heat pump for enhancing active cooling of hypersonic aircraft structure are presented. A unique heat pump arrangement which permits cooling the structure of a Mach 6 transport to aluminum temperatures without the aid of thermal shielding is described. The selected concept is compatible with the use of conventional refrigerants, with Freon R-11 selected as the preferred refrigerant. Condenser temperatures were limited to levels compatible with the use of conventional refrigerants by incorporating a unique multipass condenser design, which extracts mechanical energy from the hydrogen fuel, prior to each subsequent pass through the condenser. Results show that it is technically feasible to use a large capacity heat pump in lieu of external shielding. Additional analyses are required to optimally apply this concept.
Development of a Proof of Concept Low Temperature Superfluid Magnetic Pump with Applications
NASA Astrophysics Data System (ADS)
Jahromi, Amir E.
State of the art particle and photon detectors such as Transition Edge Sensors (TES) and Microwave Kinetic Inductance Detectors (MKID) use large arrays of sensors or detectors for space science missions. As the size of these space science detectors increases, future astrophysics missions will require sub-Kelvin coolers over larger areas. This leads to not only increased cooling power requirements, but also a requirement for distributed sub-Kelvin cooling. Development of a proof of concept Superfluid Magnetic Pump is discussed in this work. This novel low temperature, no moving part pump can replace the existing bellows-piston driven 4He or 3He- 4He mixture compressor/circulators used in various sub Kelvin refrigeration systems such as dilution, Superfluid pulse tube, or active magnetic regenerative refrigerators. Due to its superior thermal transport properties this pump can also be used as a simple circulator of sub-Lambda 4He to distribute cooling over large surface areas. The pump discussed in this work was experimentally shown to produce a maximum flow rate of 440 mg/s (averaged over cycle), 665 mg/s (peak) and produced a maximum pressure difference of 2323 Pascal. This pump worked in an "ideal" thermodynamic state: The experimental results matched with the theoretical values predicted by a computer model. Pump curves were developed to map the performance of this pump. This successful demonstration will enable this novel pump to be put to test in suitable sub Kelvin refrigeration systems. Numerical modeling of an Active Magnetic Regenerative Refrigerator (AMRR) that uses the Superfluid Magnetic Pump (SMP) to circulate liquid 3He-4He through a magnetic regenerator is presented as a potential application of such a pump.
High temperature semiconductor diode laser pumps for high energy laser applications
NASA Astrophysics Data System (ADS)
Campbell, Jenna; Semenic, Tadej; Guinn, Keith; Leisher, Paul O.; Bhunia, Avijit; Mashanovitch, Milan; Renner, Daniel
2018-02-01
Existing thermal management technologies for diode laser pumps place a significant load on the size, weight and power consumption of High Power Solid State and Fiber Laser systems, thus making current laser systems very large, heavy, and inefficient in many important practical applications. To mitigate this thermal management burden, it is desirable for diode pumps to operate efficiently at high heat sink temperatures. In this work, we have developed a scalable cooling architecture, based on jet-impingement technology with industrial coolant, for efficient cooling of diode laser bars. We have demonstrated 60% electrical-to-optical efficiency from a 9xx nm two-bar laser stack operating with propylene-glycolwater coolant, at 50 °C coolant temperature. To our knowledge, this is the highest efficiency achieved from a diode stack using 50 °C industrial fluid coolant. The output power is greater than 100 W per bar. Stacks with additional laser bars are currently in development, as this cooler architecture is scalable to a 1 kW system. This work will enable compact and robust fiber-coupled diode pump modules for high energy laser applications.
Two-Photon Pumped Synchronously Mode-Locked Bulk GaAs Laser
NASA Astrophysics Data System (ADS)
Cao, W. L.; Vaucher, A. M.; Ling, J. D.; Lee, C. H.
1982-04-01
Pulses 7 picoseconds or less in duration have been generated from a bulk GaAs crystal by a synchronous mode-locking technique. The GaAs crystal was optically pumped by two-photon absorption of the emission from a mode-locked Nd:glass laser. Two-photon absorption as the means of excitation increases the volume of the gain medium by increasing the pene-tration depth of the pump intensity, enabling generation of intra-cavity pulses with peak power in the megawatt range. Tuning of the wavelength of the GaAs emission is achieved by varying the temperature. A tuning range covering 840 nm to 885 nm has been observed over a temperature range from 97°K to 260°K. The intensity of the GaAs emission has also been observed to decrease as the temperature of the crystal is increased.
Tunable diode laser-pumped Tm,Ho:YLF laser operated in continuous-wave and Q-switched modes
NASA Technical Reports Server (NTRS)
Mcguckin, B. T.; Hemmati, H.; Menzies, R. T.
1992-01-01
Tunable continuous-wave and pulsed laser output was obtained from a Tm-sensitized Ho:YLiF4 crystal at subambient temperatures when longitudinally pumped with a diode laser array. A conversion efficiency of 42 percent and slope efficiency of approximately 60 percent relative to the absorbed pumped power have been achieved at a crystal temperature of 275 K. The emission spectrum was etalon tunable over a range of 16/cm centered at 2067 nm with fine tuning capability of the transition frequency with crystal temperature at measured rate of -0.03/cm/K. Output energies of 0.22 mJ per pulse and 22 ns pulse duration were recorded at Q-switch frequencies that correspond to an effective upper laser level lifetime of 6 ms, and a pulse energy extraction efficiency of 64 percent.
ERIC Educational Resources Information Center
Batchelor, Denise
2012-01-01
Being on the borderline as a student in higher education is not always negative, to do with marginalisation, exclusion and having a voice that is vulnerable. Paradoxically, being on the edge also has positive connections with integration, inclusion and having a voice that is strong. Alternative understandings of the concept of borderline space can…
Parenting Children with Borderline Intellectual Functioning: A Unique Risk Population
ERIC Educational Resources Information Center
Fenning, Rachel M.; Baker, Jason K.; Baker, Bruce L.; Crnic, Keith A.
2007-01-01
Parenting was examined among families of children with borderline intelligence in comparison to families of typically developing children and children with developmental delays. Parenting data were obtained at child age 5 via naturalistic home observation. Mothers of children with borderline intelligence exhibited less positive and less sensitive…
Borderline Personality Disorder: Too Complex for Cognitive Therapy?
ERIC Educational Resources Information Center
Pretzer, James L.
Historically, the literature on psychotherapy with borderline personality disorder has been based on object-relations theory or psychoanalytical approaches, rather than cognitive and behavioral approaches. In clinical assessment, the term borderline has been used to refer to patients with both neurotic and psychotic symptoms, a particular type of…
The Families of Borderline Patients
2009-01-01
We examine the families of patients with borderline personality disorder. According to existing data, the family members of individuals with borderline personality disorder have higher-than-expected levels of psychopathology, particularly with regard to mood, impulse, substance use, and Axis II disorders. Likewise, in the empirical literature, patients with borderline personality disorder seem to consistently portray parents in a very negative light. Collectively, this information suggests that there may be considerable levels of psychopathology in the families of patients with borderline personality disorder. In terms of family treatment, there is very little available information. Reported strategies seem to focus on psychoeducation, in addition to skills training and problem solving, and there are a number of educational resources for families on the web. Overall, this area is clearly in need of further research. PMID:19724744
Reynolds, Caleb J; Tragesser, Sarah L
2018-04-03
To determine whether core features of borderline personality disorder are associated with increased rates of being on disability benefits due to chronic pain conditions. A total of 147 patients currently in treatment for chronic pain at a multimodal chronic pain clinic. We tested for a concurrent relationship between borderline personality disorder features and employment status using self-report measures. Borderline personality disorder features were associated with increased likelihood of currently being on disability due to pain conditions (odds ratio [OR] = 23.13, 95% confidence interval [CI] = 1.68-318.73), on disability due to other conditions (OR = 33.65, 95% CI = 2.15-526.13), and unemployed (OR = 20.14, 95% CI = 1.38-294.93), even while controlling for pain severity and interference, depression, and trait anxiety. A follow-up analysis revealed that these associations were due to the negative relationships facet of borderline personality disorder features. Borderline personality disorder features, particularly negative relationships, are associated with increased rates of pain disability, general disability, and unemployment in a chronic pain sample. Future research should examine mechanisms by which the maladaptive interpersonal behaviors and cognitions of borderline personality disorder might result in worse long-term employment outcomes of chronic pain.
2013-01-01
Background Screening scales for bipolar disorder including the Mood Disorder Questionnaire (MDQ) and Bipolar Spectrum Diagnostic Scale (BSDS) have been plagued by high false positive rates confounded by presence of borderline personality disorder. This study examined the accuracy of these scales for detecting bipolar disorder among patients referred for eating disorders and explored the possibility of simultaneous assessment of co-morbid borderline personality disorder. Methods Participants were 78 consecutive female patients who were referred for evaluation of an eating disorder. All participants completed the mood and eating disorder sections of the SCID-I/P and the borderline personality disorder section of the SCID-II, in addition to the MDQ and BSDS. Predictive validity of the MDQ and BSDS was evaluated by Receiver Operating Characteristic analysis of the Area Under the Curve (AUC). Results Fifteen (19%) and twelve (15%) patients fulfilled criteria for bipolar II disorder and borderline personality disorder, respectively. The AUCs for bipolar II disorder were 0.78 (MDQ) and 0.78 (BDSD), and the AUCs for borderline personality disorder were 0.75 (MDQ) and 0.79 (BSDS). Conclusions Among patients being evaluated for eating disorders, the MDQ and BSDS show promise as screening questionnaires for both bipolar disorder and borderline personality disorder. PMID:23443034
Proceedings of the Annual Conference on Manual Control (18th) Held at Dayton, Ohio on 8-10 June 1982
1983-01-01
frequency of the disturbance the probability to cross the borderline becomes larger, and corrective action (moving average value further away-,_. from the...pupillometer. The prototypical data was the average of 10 records from 5 normal subjects who showed similar responses. The different amplitudes of light...following orders touch, position, temperature , and vain. Our subjects sometimes reported numbness in the fingertips, dulled pinprick sensations
NASA Astrophysics Data System (ADS)
Kowsz, Stacy J.; Pynn, Christopher D.; Wu, Feng; Farrell, Robert M.; Speck, James S.; DenBaars, Steven P.; Nakamura, Shuji
2016-02-01
We report a semipolar III-nitride device in which an electrically injected blue light emitting diode optically pumps monolithic long wavelength emitting quantum wells (QWs) to create polarized white light. We have demonstrated an initial device with emission peaks at 440 nm and 560 nm from the electrically injected and optically pumped QWs, respectively. By tuning the ratio of blue to yellow, white light was measured with a polarization ratio of 0.40. High indium content InGaN is required for long wavelength emission but is difficult to achieve because it requires low growth temperatures and has a large lattice mismatch with GaN. This device design incorporates optically pumped QWs for long wavelength emission because they offer advantages over using electrically injected QWs. Optically pumped QWs do not have to be confined within a p-n junction, and carrier transport is not a concern. Thus, thick GaN barriers can be incorporated between multiple InGaN QWs to manage stress. Optically pumping long wavelength emitting QWs also eliminates high temperature steps that degrade high indium content InGaN but are required when growing p-GaN for an LED structure. Additionally, by eliminating electrical injection, the doping profile can instead be engineered to affect the emission wavelength. We discuss ongoing work focused on improving polarized white light emission by optimizing the optically pumped QWs. We consider the effects of growth conditions, including: trimethylindium (TMI) flow rate, InGaN growth rate, and growth temperature. We also examine the effects of epitaxial design, including: QW width, number of QWs, and doping.
NASA Astrophysics Data System (ADS)
Bogdanovich, M. V.; Izyneev, A. A.; Lantsov, K. I.; Lepchenkov, K. V.; Ryabtsev, A. G.; Pavlovskii, V. N.; Sadovskii, P. I.; Svitenkov, I. E.; Shchemelev, M. A.
2018-03-01
Temperature effects on photoluminescence and absorption spectra of the active medium (LGS-DE erbium phosphate glass) and passive Q-switch (MgAl2O4:Co2+ crystal) of a diode-side pumped Yb,Er-laser are studied. The obtained data are applied to an analysis of the spectral and energetic characteristics of compact erbium emitters. It is established that the dominant generation channel in the temperature range 233-328 K is the optical transition between lower Stark sublevels of Er3+ states 4I13/2 and 4I15/2 (λ = 1532.0-1533.9 nm). A rate-equation system taking into account thermal population of Stark sublevels of states 4I13/2 and 4I15/2 is proposed to describe the experimental temperature dependence of the threshold absorbed power of the pumping radiation. This system and the lasing threshold enable modeling of Yb,Er-emitter output energetic and temporal characteristics.
NASA Astrophysics Data System (ADS)
Liu, Jianwei; Liu, Jiaquan; Wang, Fengyin; Wang, Cuiping
2018-03-01
The thermal environment parameters, like the temperature and air velocity, are measured to investigate the heat comfort status of metro staff working area in winter in Qingdao. The temperature is affected obviously by the piston wind from the train and waiting hall in the lower Hall, and the temperature is not satisfied with the least heat comfort temperature of 16 °C. At the same time, the heat produced by the electrical and control equipments is brought by the cooling air to atmosphere for the equipment safety. Utilizing the water-circulating heat pump, it is feasible to transfer the emission heat to the staff working area to improve the thermal environment. Analyzed the feasibility from the technique and economy when using the heat pump, the water-circulating heat pump could be the best way to realize the waste heat recovery and to help the heat comfort of staff working area in winter in the underground metro station in north China.
Temperature feedback control for long-term carrier-envelope phase locking.
Yun, Chenxia; Chen, Shouyuan; Wang, He; Chini, Michael; Chang, Zenghu
2009-09-20
We report a double feedback loop for the improvement of the carrier-envelope phase stabilization of a chirped mirror based femtosecond laser oscillator. By combining the control of the Ti:sapphire crystal temperature and the modulation of the pump power, the carrier envelope offset frequency, fCEO, was locked for close to 20 h, which is much longer than the typical phase stabilization time with only pump power modulation.
Solar powered blackbody-pumped lasers
NASA Astrophysics Data System (ADS)
Christiansen, Walter H.; Sirota, J. M.
1991-02-01
A concept for a solar-powered laser is presented which utilizes an intermediate blackbody cavity to provide a uniform optical pumping environment for the lasant, typically CO or CO2 or possibly a solid state laser medium. High power cw blackbody- pumped lasers with efficiencies on the order of 20 percent or more are feasible. The physical basis of this idea is reviewed. Small scale experiments using a high temperature oven as the optical pump have been carried out with gas laser mixtures. Detailed calculations showing a potential efficiency of 35 percent for blackbody pumped Nd:YAG system are discussed.
A Non-linear Predictive Model of Borderline Personality Disorder Based on Multilayer Perceptron.
Maldonato, Nelson M; Sperandeo, Raffaele; Moretto, Enrico; Dell'Orco, Silvia
2018-01-01
Borderline Personality Disorder is a serious mental disease, classified in Cluster B of DSM IV-TR personality disorders. People with this syndrome presents an anamnesis of traumatic experiences and shows dissociative symptoms. Since not all subjects who have been victims of trauma develop a Borderline Personality Disorder, the emergence of this serious disease seems to have the fragility of character as a predisposing condition. Infect, numerous studies show that subjects positive for diagnosis of Borderline Personality Disorder had scores extremely high or extremely low to some temperamental dimensions (harm Avoidance and reward dependence) and character dimensions (cooperativeness and self directedness). In a sample of 602 subjects, who have had consecutive access to an Outpatient Mental Health Service, it was evaluated the presence of Borderline Personality Disorder using the semi-structured interview for the DSM IV-TR personality disorders. In this population we assessed the presence of dissociative symptoms with the Dissociative Experiences Scale and the personality traits with the Temperament and Character Inventory developed by Cloninger. To assess the weight and the predictive value of these psychopathological dimensions in relation to the Borderline Personality Disorder diagnosis, a neural network statistical model called "multilayer perceptron," was implemented. This model was developed with a dichotomous dependent variable, consisting in the presence or absence of the diagnosis of borderline personality disorder and with five covariates. The first one is the taxonomic subscale of dissociative experience scale, the others are temperamental and characterial traits: Novelty-Seeking, Harm-Avoidance, Self-Directedness and Cooperativeness. The statistical model, that results satisfactory, showed a significance capacity (89%) to predict the presence of borderline personality disorder. Furthermore, the dissociative symptoms seem to have a greater influence than the character traits in the borderline personality disorder e disease. In conclusion, the results seem to indicate that to borderline personality disorder development, contribute both psychic factors, such as temperament and character traits, and environmental factors, such as traumatic events capable of producing dissociative symptoms. These factors interact in a nonlinear way in producing maladaptive behaviors typical of this disorder.
Exploding conducting film laser pumping apparatus
Ware, Kenneth D.; Jones, Claude R.
1986-01-01
Exploding conducting film laser optical pumping apparatus. The 342-nm molecular iodine and the 1.315-.mu.m atomic iodine lasers have been optically pumped by intense light from exploding-metal-film discharges. Brightness temperatures for the exploding-film discharges were approximately 25,000 K. Although lower output energies were achieved for such discharges when compared to exploding-wire techniques, the larger surface area and smaller inductance inherent in the exploding-film should lead to improved efficiency for optically-pumped gas lasers.
2015-05-18
Figure 14: Pump and motor mounting assembly Solenoid valves Water Heater Ball Valves Spray nozzles Compressor Discharge Scroll Pump ...configuration schematic ........................................................................ 31 Figure 14: Pump and motor mounting assembly...Tubes (1 each side) Compressor Discharge Scroll 11 compared to the same engine cycle without the gas generator turbine stage. A temperature
An alternative physiological role for the EmhABC efflux pump in Pseudomonas fluorescens cLP6a
2011-01-01
Background Efflux pumps belonging to the resistance-nodulation-division (RND) superfamily in bacteria are involved in antibiotic resistance and solvent tolerance but have an unknown physiological role. EmhABC, a RND-type efflux pump in Pseudomonas fluorescens strain cLP6a, extrudes hydrophobic antibiotics, dyes and polycyclic aromatic hydrocarbons including phenanthrene. The effects of physico-chemical factors such as temperature or antibiotics on the activity and expression of EmhABC were determined in order to deduce its physiological role(s) in strain cLP6a in comparison to the emhB disruptant strain, cLP6a-1. Results Efflux assays conducted with 14C-phenanthrene showed that EmhABC activity is affected by incubation temperature. Increased phenanthrene efflux was measured in cLP6a cells grown at 10°C and decreased efflux was observed at 35°C compared with cells grown at the optimum temperature of 28°C. Membrane fatty acids in cLP6a cells were substantially altered by changes in growth temperature and in the presence of tetracycline. Changed membrane fatty acids and increased membrane permeability were associated with ~30-fold increased expression of emhABC in cLP6a cells grown at 35°C, and with increased extracellular free fatty acids. Growth of P. fluorescens cLP6a at supra-optimal temperature was enhanced by the presence of EmhABC compared to strain cLP6a-1. Conclusions Combined, these observations suggest that the EmhABC efflux pump may be involved in the management of membrane stress effects such as those due to unfavourable incubation temperatures. Efflux of fatty acids replaced as a result of membrane damage or phospholipid turnover may be the primary physiological role of the EmhABC efflux pump in P. fluorescens cLP6a. PMID:22085438
Development of a Compact, Efficient Cooling Pump for Space Suit Life Support Systems
NASA Technical Reports Server (NTRS)
van Boeyen, Roger; Reeh, Jonathan; Trevino, Luis
2009-01-01
A compact, low-power electrochemically-driven fluid cooling pump is currently being developed by Lynntech, Inc. With no electric motor and minimal lightweight components, the pump is significantly lighter than conventional rotodynamic and displacement pumps. Reliability and robustness is achieved with the absence of rotating or moving components (apart from the bellows). By employing sulfonated polystyrene-based proton exchange membranes, rather than conventional Nafion membranes, a significant reduction in the actuator power consumption was demonstrated. Lynntech also demonstrated that these membranes possess the necessary mechanical strength, durability, and temperature range for long life space operation. The preliminary design for a Phase II prototype pump compares very favorably to the fluid cooling pumps currently used in space suit primary life support systems (PLSSs). Characteristics of the electrochemically-driven pump are described and the benefits of the technology as a replacement for electric motor pumps in mechanically pumped single-phase fluid loops is discussed.
NASA Astrophysics Data System (ADS)
Verma, R.; Shivaprakash, N. C.; Kasthurirengan, S.; Behera, U.
2017-12-01
Cryosorption pump is a capture vacuum pump which retains gas molecules by chemical or physical interaction on their internal surfaces when cooled to cryogenic temperatures. Cryosorption pumps are the only solution in nuclear fusion systems to achieve high vacuum in the environment of hydrogen and helium. An important aspect of this development is the proper adhesion of the activated carbons on the metallic panels using a high thermal conductivity and high bonding strength adhesive. Typical adhesives used are epoxy based. The thermal conductivity of the adhesive can be improved by using fine aluminium powder as the filler in the base epoxy matrix. However, the thermal conductivity data of such epoxy-aluminium composites is not available in literature. Hence, we have measured the thermal conductivities of the above epoxy-aluminium composites (with varied volume fraction of aluminium in epoxy) in the temperature range from 4.5 K to 300 K using a G-M cryocooler based thermal conductivity experimental set-up. The experimental results are discussed in this paper which will be useful towards the development of cryosoprtion pumps with high pumping speeds.
Ambe, Chenwi M; Nguyen, Phuong; Centeno, Barbara A; Choi, Junsung; Strosberg, Jonathan; Kvols, Larry; Hodul, Pamela; Hoffe, Sarah; Malafa, Mokenge P
2017-01-01
Pancreatic neuroendocrine tumors (PanNETs) constitute approximately 3% of pancreatic neoplasms. Like patients with pancreatic ductal adenocarcinoma (PDAC), some of these patients present with "borderline resectable disease." For these patients, an optimal treatment approach is lacking. We report our institution's experience with borderline resectable PanNETs using multimodality treatment. We identified patients with borderline resectable PanNETs who had received neoadjuvant therapy at our institution between 2000 and 2013. The definition of borderline resectability was based on National Comprehensive Cancer Network criteria for PDAC. Neoadjuvant regimen, radiographic response, pathologic response, surgical margins, nodal retrieval, number of positive nodes, and recurrence were documented. Statistics were descriptive. Of 112 patients who underwent surgical resection for PanNETs during the study period, 23 received neoadjuvant therapy, 6 of whom met all inclusion criteria and had borderline resectable disease. These 6 patients received at least 1 cycle of temozolomide and capecitabine, with 3 also receiving radiation. All had radiographic evidence of treatment response. Four (67%) had negative-margin resections. Four patients had histologic evidence of a moderate response. Follow-up (3.0-4.3 years) indicated that all patients were alive, with 5/6 free of disease (1 patient with metastatic disease still on treatment without progression). A multimodality treatment strategy (neoadjuvant temozolomide and capecitabine ± radiation) can be successfully applied to patients with PanNETs who meet NCCN borderline resectable criteria for PDAC. To our knowledge, this is the first report of the use of a multimodality protocol in the treatment of patients with borderline resectable PanNETs.
Numerical simulation of the cavitation characteristics of a mixed-flow pump
NASA Astrophysics Data System (ADS)
Chen, T.; Li, S. R.; Li, W. Z.; Liu, Y. L.; Wu, D. Z.; Wang, L. Q.
2013-12-01
As a kind of general equipment for fluid transportation, pumps were widely used in industry which includes many applications of high pressure, temperature and toxic fluids transportations. Performances of pumps affect the safety and reliability of the whole special equipment system. Cavitation in pumps cause the loss of performance and erosion of the blade, which could affect the running stability and reliability of the pump system. In this paper, a kind of numerical method for cavitaion performance prediction was presented. In order to investigate the accuracy of the method, CFD flow analysis and cavitation performance predictions of a mixed-flow pump were carried out. The numerical results were compared with the test results.
de Bruin, Jeroen S; Adlassnig, Klaus-Peter; Blacky, Alexander; Koller, Walter
2016-05-01
Many electronic infection detection systems employ dichotomous classification methods, classifying patient data as pathological or normal with respect to one or several types of infection. An electronic monitoring and surveillance system for healthcare-associated infections (HAIs) known as Moni-ICU is being operated at the intensive care units (ICUs) of the Vienna General Hospital (VGH) in Austria. Instead of classifying patient data as pathological or normal, Moni-ICU introduces a third borderline class. Patient data classified as borderline with respect to an infection-related clinical concept or HAI surveillance definition signify that the data nearly or partly fulfill the definition for the respective concept or HAI, and are therefore neither fully pathological nor fully normal. Using fuzzy sets and propositional fuzzy rules, we calculated how frequently patient data are classified as normal, borderline, or pathological with respect to infection-related clinical concepts and HAI definitions. In dichotomous classification methods, borderline classification results would be confounded by normal. Therefore, we also assessed whether the constructed fuzzy sets and rules employed by Moni-ICU classified patient data too often or too infrequently as borderline instead of normal. Electronic surveillance data were collected from adult patients (aged 18 years or older) at ten ICUs of the VGH. All adult patients admitted to these ICUs over a two-year period were reviewed. In all 5099 patient stays (4120 patients) comprising 49,394 patient days were evaluated. For classification, a part of Moni-ICU's knowledge base comprising fuzzy sets and rules for ten infection-related clinical concepts and four top-level HAI definitions was employed. Fuzzy sets were used for the classification of concepts directly related to patient data; fuzzy rules were employed for the classification of more abstract clinical concepts, and for top-level HAI surveillance definitions. Data for each clinical concept and HAI definition were classified as either normal, borderline, or pathological. For the assessment of fuzzy sets and rules, we compared how often a borderline value for a fuzzy set or rule would result in a borderline value versus a normal value for its associated HAI definition(s). The statistical significance of these comparisons was expressed in p-values calculated with Fisher's exact test. The results showed that, for clinical concepts represented by fuzzy sets, 1-17% of the data were classified as borderline. The number was substantially higher (20-81%) for fuzzy rules representing more abstract clinical concepts. A small body of data were found to be in the borderline range for the four top-level HAI definitions (0.02-2.35%). Seven of ten fuzzy sets and rules were associated significantly more often with borderline values than with normal values for their respective HAI definition(s) (p<0.001). The study showed that Moni-ICU was effective in classifying patient data as borderline for infection-related concepts and top-level HAI surveillance definitions. Copyright © 2016 Elsevier B.V. All rights reserved.
Adolescent Borderline Symptoms in the Community: Prognosis for Functioning over 20 Years
ERIC Educational Resources Information Center
Winograd, Greta; Cohen, Patricia; Chen, Henian
2008-01-01
Background: The long-term prognosis associated with adolescent symptoms of borderline personality disorder (BPD) in the general population is virtually unknown. In this study, the relationship of early borderline symptoms to subsequent psychosocial functioning and attainment was investigated based on data from the Children in the Community cohort.…
ERIC Educational Resources Information Center
Embregts, P.; van Nieuwenhuijzen, M.
2009-01-01
Background: Children with autistic spectrum disorders (ASD) and mild to borderline intellectual disability (ID) have less adaptive behaviour and more behaviour problems than children with mild to borderline ID. Social information processing appears to be an important mechanism in the explanation of the socially inadequate behaviour of children…
Use of Dialectical Behavior Therapy in Borderline Personality Disorder: A View from Residency
ERIC Educational Resources Information Center
Sharma, Binali; Dunlop, Boadie W.; Ninan, Philip T.; Bradley, Rebekah
2007-01-01
Objective: The authors describe the use of dialectical behavior therapy (DBT) in treating borderline personality disorder during psychiatry residency, and assess the status of DBT education within psychiatry residencies in the United States. Method: The authors present a patient with borderline personality disorder treated by a resident using DBT,…
2016-10-20
Fallopian Tube Carcinoma; Primary Peritoneal Carcinoma; Recurrent Borderline Ovarian Surface Epithelial-Stromal Tumor; Recurrent Ovarian Carcinoma; Stage III Borderline Ovarian Surface Epithelial-Stromal Tumor; Stage III Ovarian Cancer; Stage IV Borderline Ovarian Surface Epithelial-Stromal Tumor; Stage IV Ovarian Cancer
The Borderline/Schizoid Marriage: The Holding Environment as an Essential Treatment Construct.
ERIC Educational Resources Information Center
McCormack, Charles C.
1989-01-01
Discusses the borderline/schizoid marital constellation as the prominent constellation among borderline patients on a long-term inpatient unit. Contends that treatment of this marital constellation requires application of the concept of the holding environment as an essential treatment construct with the therapist as manager of the holding…
Feliu-Soler, Albert; Pascual, Juan Carlos; Elices, Matilde; Martín-Blanco, Ana; Carmona, Cristina; Cebolla, Ausiàs; Simón, Vicente; Soler, Joaquim
2017-01-01
The aim of this randomized pilot study is to investigate the effects of a short training programme in loving-kindness and compassion meditation (LKM/CM) in patients with borderline personality disorder. Patients were allocated to LKM/CM or mindfulness continuation training (control group). Patients in the LKM/CM group showed greater changes in Acceptance compared with the control group. Remarkable changes in borderline symptomatology, self-criticism and self-kindness were also observed in the LKM/CM group. Mechanistic explanations and therapeutic implications of the findings are discussed. Three weeks of loving-kindness and compassion meditations increased acceptance of the present-moment experience in patients with borderline personality disorder. Significant improvements in the severity of borderline symptoms, self-criticism, mindfulness, acceptance and self-kindness were observed after the LKM/CM intervention. LKM/CM is a promising complementary strategy for inclusion in mindfulness-based interventions and Dialectical Behavioural Therapy for treating core symptoms in borderline personality disorder. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Banny, Adrienne M; Tseng, Wan-Ling; Murray-Close, Dianna; Pitula, Clio E; Crick, Nicki R
2014-08-01
The present longitudinal investigation examined borderline personality features as a predictor of aggression 1 year later. Moderation by physiological reactivity and gender was also explored. One hundred ninety-six children (M = 10.11 years, SD = 0.64) participated in a laboratory stress protocol in which their systolic blood pressure, diastolic blood pressure, and skin conductance reactivity to recounting a relational stressor (e.g., threats to relationships or exclusion) were assessed. Teachers provided reports on subtypes of aggressive behavior (i.e., reactive relational, proactive relational, reactive physical, and proactive physical), and children completed a self-report measure of borderline personality features. Path analyses indicated that borderline personality features predicted increases in reactive relational aggression and proactive relational aggression among girls who evinced heightened physiological reactivity to interpersonal stress. In contrast, borderline personality features predicted decreases in proactive physical aggression in girls. Findings suggest that borderline personality features promote engagement in relationally aggressive behaviors among girls, particularly in the context of emotional dysregulation.
In vivo study of flow-rate accuracy of the MedStream Programmable Infusion System.
Venugopalan, Ramakrishna; Ginggen, Alec; Bork, Toralf; Anderson, William; Buffen, Elaine
2011-01-01
Flow-rate accuracy and precision are important parameters to optimizing the efficacy of programmable intrathecal (IT) infusion pump delivery systems. Current programmable IT pumps are accurate within ±14.5% of their programmed infusion rate when assessed under ideal environmental conditions and specific flow-rate settings in vitro. We assessed the flow-rate accuracy of a novel programmable pump system across its entire flow-rate range under typical conditions in sheep (in vivo) and nominal conditions in vitro. The flow-rate accuracy of the MedStream Programmable Pump was assessed in both the in vivo and in vitro settings. In vivo flow-rate accuracy was assessed in 16 sheep at various flow-rates (producing 90 flow intervals) more than 90 ± 3 days. Pumps were then explanted, re-sterilized and in vitro flow-rate accuracy was assessed at 37°C and 1013 mBar (80 flow intervals). In vivo (sheep body temperatures 38.1°C-39.8°C), mean ± SD flow-rate error was 9.32% ± 9.27% and mean ± SD leak-rate was 0.028 ± 0.08 mL/day. Following explantation, mean in vitro flow-rate error and leak-rate were -1.05% ± 2.55% and 0.003 ± 0.004 mL/day (37°C, 1013 mBar), respectively. The MedStream Programmable Pump demonstrated high flow-rate accuracy when tested in vivo and in vitro at normal body temperature and environmental pressure as well as when tested in vivo at variable sheep body temperature. The flow-rate accuracy of the MedStream Programmable Pump across its flow-rate range, compares favorably to the accuracy of current clinically utilized programmable IT infusion pumps reported at specific flow-rate settings and conditions. © 2011 International Neuromodulation Society.
Borderline Personality Disorder: Ontogeny of a Diagnosis
Gunderson, John G.
2011-01-01
Objective The purpose of this article is to describe the development of the borderline personality disorder diagnosis, highlighting both the obstacles encountered and the associated achievements. Method On the basis of a review of the literature, the author provides a chronological account of the borderline construct in psychiatry, summarizing progress in decade-long intervals. Results Borderline personality disorder has moved from being a psychoanalytic colloquialism for untreatable neurotics to becoming a valid diagnosis with significant heritability and with specific and effective psychotherapeutic treatments. Nonetheless, patients with this disorder pose a major public health problem while they themselves remain highly stigmatized and largely neglected. Conclusions Despite remarkable changes in our knowledge about borderline personality disorder, increased awareness involving much more education and research is still needed. Psychiatric institutions, professional organizations, public policies, and reimbursement agencies need to prioritize this need. PMID:19411380
Temperature influence on diode pumped Yb:GGAG laser
NASA Astrophysics Data System (ADS)
Veselský, Karel; Boháček, Pavel; Šulc, Jan; Jelínková, Helena; Trunda, Bohumil; Havlák, Lubomír.; Jurek, Karel; Nikl, Martin
2017-05-01
We present temperature influence (in range from 78 up to 400,K) on spectroscopic properties and laser performance of new Yb-doped mixed garnet Gd3GaxAl5-xO12 (Yb:GGAG). The sample was 2.68 mm thick plane-parallel face-polished Yb:GGAG single-crystal plate which was AR coated for pump (930 nm) and generated (1030 nm) laser radiation wavelength. The composition of sample was Gd3.098Yb0:0897Ga2:41Al2.41O12 (3 at % Yb/Gd). The Yb:GGAG crystal was mounted in temperature controlled copper holder of the liquid nitrogen cryostat. The 138 mm long semi-hemispherical laser resonator consisted of a flat pumping mirror (T > 90 % @ 930 nm, HR @ 1030 nm) placed inside cryostat, and a curved output coupler (r = 150 mm, R = 94.5 % @ 1030 nm) placed outside cryostat. For longitudinal pumping a fiber coupled laser diode was used. The diode was operating in the pulse regime (5 ms pulse length, 20 Hz repetition rate) at wavelength 928.5 nm. The absorption spectrum was measured for the temperatures from 78 to 400 K, and absorption lines narrowing was observed with temperature decrease. Zero-phonon line at 970 nm has width 1 nm (FWHM) at 100 K. The fluorescence intensity decay time was measured and it increased linearly with temperature from 864 μs @ 78 K to 881 μs @ 300 K. The temperature of active medium has strong influence mainly on laser threshold which was 5 times lower at 100 K than at 300 K, and on slope efficiency which was 3 times higher at 100 K than at 300 K.
Climate Adaptivity and Field Test of the Space Heating Used Air-Source Transcritical CO2 Heat Pump
NASA Astrophysics Data System (ADS)
Song, Yulong; Ye, Zuliang; Cao, Feng
2017-08-01
In this study, an innovation of air-sourced transcritical CO2 heat pump which was employed in the space heating application was presented and discussed in order to solve the problem that the heating performances of the transcritical CO2 heat pump water heater deteriorated sharply with the augment in water feed temperature. An R134a cycle was adopted as a subcooling device in the proposed system. The prototype of the presented system was installed and supplied hot water for three places in northern China in winter. The field test results showed that the acceptable return water temperature can be increased up to 55°C, while the supply water temperature was raised rapidly by the presented prototype to up to 70°C directly, which was obviously appropriate to the various conditions of heating radiator in space heating application. Additionally, though the heating capacity and power dissipation decreased with the decline in ambient temperature or the augment in water temperature, the presented heat pump system performed efficiently whatever the climate and water feed temperature were. The real time COP of the presented system was generally more than 1.8 in the whole heating season, while the seasonal performance coefficient (SPC) was also appreciable, which signified that the economic efficiency of the presented system was more excellent than other space heating approaches such as fuel, gas, coal or electric boiler. As a result, the novel system will be a promising project to solve the energy issues in future space heating application.
Hudziak, J J; Boffeli, T J; Kreisman, J J; Battaglia, M M; Stanger, C; Guze, S B; Kriesman, J J
1996-12-01
The criteria for borderline personality disorder seem to select patients with very high rates of Briquet's syndrome (hysteria), somatization disorder, antisocial personality disorder, and substance abuse disorders. This study was undertaken to determine whether systematic assessment of patients with borderline personality disorder would reveal characteristic features of that condition which would distinguish it from these other disorders. Eighty-seven white female patients (75 in St. Louis and 12 in Milan, Italy) who had borderline personality disorder according to both the DSM-III-R criteria and the Revised Diagnostic Interview for Borderlines were further examined with the DSM-III-R Checklist and the Perley-Guze Hysteria Checklist to determine their patterns of psychiatric comorbidity. Every patient had at least one additional DSM diagnosis. Patients in St. Louis and Milan averaged five and four additional diagnoses, respectively. Eighty-four percent of the patients in St. Louis met criteria for either somatization disorder, Briquet's syndrome, antisocial personality disorder, or substance abuse disorders. Patterns of comorbidity for panic (51%), generalized anxiety disorder (55%), and major depression (87%) in St. Louis were consistent with those in other studies. The data indicate that the boundaries for the borderline condition are not specific and identify a high percentage of patients with these other disorders. Furthermore, the comorbidity profiles closely resemble the psychiatric profiles of patients with these disorders. If the borderline syndrome is meant to include all of these disorders, its usefulness as a diagnosis is limited. Until the fundamental features of borderline personality disorder that distinguish it from the others are identified, it is recommended that clinicians carefully assess patients for these other diagnoses. Efforts should be made to change the borderline personality disorder criteria by shifting away from overlap with the criteria for the other disorders.
Serum Lipid Levels and Dyslipidaemia Prevalence among 2–10 Year-Old Northern Mexican Children
Bibiloni, Maria del Mar; Salas, Rogelio; Novelo, Hilda I.; Villarreal, Jesús Z.; Sureda, Antoni; Tur, Josep A.
2015-01-01
Background and Aims The increase in overweight and obese children may be linked to increased rates of dyslipidaemia. The aim was to assess the prevalence of dyslipidaemia and associated risk factors among the Northern Mexican child population. Methods and Results Four hundred and fifty-one subjects aged between 2 and 10 (47.5% girls) took part in the Nuevo León State Survey of Nutrition and Health 2011–2012. According to the 2011 Expert Panel on Integrated Guidelines for Cardiovascular Health and Risk Reduction in Children and Adolescents, serum lipid levels (mg/dL) were categorized into three subgroups (acceptable, borderline-high/low or high/low) as follows: TChol: acceptable <170, borderline-high 170–199, high ≥200; LDL-chol: acceptable <110, borderline-high 110–129, high ≥130; non-HDL-chol: acceptable <120, borderline-high 120–144, high ≥145; HDL-chol: acceptable >45, borderline-low 40–45, low <40; and TG: acceptable <75, borderline-high 75–99, high ≥100 in ≤9 year-old children, and acceptable <90, borderline-high 90–129, and high ≥130 in 10 year-old children. The overall prevalence of borderline-high + high TG, non-HDL-chol, TChol, and LDL-chol was 63.0%, 44.1%, 43.5%, and 29.9%, respectively. The overall prevalence of borderline-low + low HDL-chol was 46.3%. The overall frequency of dyslipidaemia was 54.3%. Thirteen children (2.9%) had all five symptoms of dyslipidaemia. The most common dyslipidaemia was high TG in combination (26.2%) and in isolation (10.6%). Conclusions Half of the children had at least one abnormal lipid concentration. A high TG level was the most frequent dyslipidaemia. Obesity was associated with the occurrence of at least one abnormal lipid level. These findings emphasize the need to pay further attention to the prevention of cardiovascular disease and obesity from an early age. PMID:25793380
Bose-Einstein condensation in an ultra-hot gas of pumped magnons.
Serga, Alexander A; Tiberkevich, Vasil S; Sandweg, Christian W; Vasyuchka, Vitaliy I; Bozhko, Dmytro A; Chumak, Andrii V; Neumann, Timo; Obry, Björn; Melkov, Gennadii A; Slavin, Andrei N; Hillebrands, Burkard
2014-03-11
Bose-Einstein condensation of quasi-particles such as excitons, polaritons, magnons and photons is a fascinating quantum mechanical phenomenon. Unlike the Bose-Einstein condensation of real particles (like atoms), these processes do not require low temperatures, since the high densities of low-energy quasi-particles needed for the condensate to form can be produced via external pumping. Here we demonstrate that such a pumping can create remarkably high effective temperatures in a narrow spectral region of the lowest energy states in a magnon gas, resulting in strikingly unexpected transitional dynamics of Bose-Einstein magnon condensate: the density of the condensate increases immediately after the external magnon flow is switched off and initially decreases if it is switched on again. This behaviour finds explanation in a nonlinear 'evaporative supercooling' mechanism that couples the low-energy magnons overheated by pumping with all the other thermal magnons, removing the excess heat, and allowing Bose-Einstein condensate formation.
Stable nonlinear Mach-Zehnder fiber switch
Digonnet, Michel J. F.; Shaw, H. John; Pantell, Richard H.; Sadowski, Robert W.
1999-01-01
An all-optical fiber switch is implemented within a short Mach-Zehnder interferometer configuration. The Mach-Zehnder switch is constructed to have a high temperature stability so as to minimize temperature gradients and other thermal effects which result in undesirable instability at the output of the switch. The Mach-Zehnder switch of the preferred embodiment is advantageously less than 2 cm in length between couplers to be sufficiently short to be thermally stable, and full switching is accomplished by heavily doping one or both of the arms between the couplers so as to provide a highly nonlinear region within one or both of the arms. A pump input source is used to affect the propagation characteristics of one of the arms to control the output coupling ratio of the switch. Because of the high nonlinearity of the pump input arm, low pump powers can be used, thereby alleviating difficulties and high cost associated with high pump input powers.
Thermodynamic and economic analysis of heat pumps for energy recovery in industrial processes
NASA Astrophysics Data System (ADS)
Urdaneta-B, A. H.; Schmidt, P. S.
1980-09-01
A computer code has been developed for analyzing the thermodynamic performance, cost and economic return for heat pump applications in industrial heat recovery. Starting with basic defining characteristics of the waste heat stream and the desired heat sink, the algorithm first evaluates the potential for conventional heat recovery with heat exchangers, and if applicable, sizes the exchanger. A heat pump system is then designed to process the residual heating and cooling requirements of the streams. In configuring the heat pump, the program searches a number of parameters, including condenser temperature, evaporator temperature, and condenser and evaporator approaches. All system components are sized for each set of parameters, and economic return is estimated and compared with system economics for conventional processing of the heated and cooled streams (i.e., with process heaters and coolers). Two case studies are evaluated, one in a food processing application and the other in an oil refinery unit.
Psychodrama and the Treatment of Narcissistic and Borderline Patients.
Olsson, Peter A
2018-01-01
Psychiatric clinicians are faced with the challenge of remaining flexible and psychotherapeutically relevant to the broadening scope of patients with severe narcissistic and borderline personality disorders. Diagnostic sophistication among mental health professionals, increased availability of psychotherapy services, and economic pressures combine to cause the public to expect cost-effective, successful, and shorter duration of treatments. These treatment challenges are particularly poignant with the treatment of those narcissistic and borderline patients who have meager capacity for insight and limited verbal skills. This article describes the use of psychodynamically oriented and informed psychodrama for the treatment of narcissistic and borderline patients.
Definition and Management of Borderline Resectable Pancreatic Cancer.
Denbo, Jason W; Fleming, Jason B
2016-12-01
Patients with localized pancreatic ductal adenocarcinoma seek potentially curative treatment, but this group represents a spectrum of disease. Patients with borderline resectable primary tumors are a unique subset whose successful therapy requires a care team with expertise in medical care, imaging, surgery, medical oncology, and radiation oncology. This team must identify patients with borderline tumors then carefully prescribe and execute a combined treatment strategy with the highest possibility of cure. This article addresses the issues of clinical evaluation, imaging techniques, and criteria, as well as multidisciplinary treatment of patients with borderline resectable pancreatic ductal adenocarcinoma. Copyright © 2016 Elsevier Inc. All rights reserved.
Liu, Jian-Hua; Jing, Dong-Yang; Wang, Liang-Liang; Li, Yang; Quan, Wei; Fang, Jian-Cheng; Liu, Wu-Ming
2017-07-28
The hybrid optical pumping spin exchange relaxation free (SERF) atomic magnetometers can realize ultrahigh sensitivity measurement of magnetic field and inertia. We have studied the 85 Rb polarization of two types of hybrid optical pumping SERF magnetometers based on 39 K- 85 Rb- 4 He and 133 Cs- 85 Rb- 4 He respectively. Then we found that 85 Rb polarization varies with the number density of buffer gas 4 He and quench gas N 2 , pumping rate of pump beam and cell temperature respectively, which will provide an experimental guide for the design of the magnetometer. We obtain a general formula on the fundamental sensitivity of the hybrid optical pumping SERF magnetometer due to shot-noise. The formula describes that the fundamental sensitivity of the magnetometer varies with the number density of buffer gas and quench gas, the pumping rate of pump beam, external magnetic field, cell effective radius, measurement volume, cell temperature and measurement time. We obtain a highest fundamental sensitivity of 1.5073 aT/Hz 1/2 (1 aT = 10 -18 T) with 39 K- 85 Rb- 4 He magnetometer between above two types of magnetometers when 85 Rb polarization is 0.1116. We estimate the fundamental sensitivity limit of the hybrid optical pumping SERF magnetometer to be superior to 1.8359 × 10 -2 aT/Hz 1/2 , which is higher than the shot-noise-limited sensitivity of 1 aT/Hz 1/2 of K SERF atomic magnetometer.
Simulation of an ammonia-water heat pump water heater with combustion products-driven evaporator
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perez-Blanco, Horacio; Gluesenkamp, K.; Ally, Moonis Raza
Here, the objective of this work is to simulate a single effct (SE) ammonia-water heat pump for domestic water heating, with innovative aspects for cycle simulation and eventual implementation. Seasonal temperature variations demand verfication of distillation column viability. For the given application and temperature ranges, it is found that some variables need to be controlled if the same column is to be used all year round. In addition, a number of simplifications are considered in this work: an advanced evaporator requireing minimal gas flow and surface area, subcooling at two crucial spots of the cycle and the viability of somemore » pump designs to assuage cavitation issues.« less
Simulation of an ammonia-water heat pump water heater with combustion products-driven evaporator
Perez-Blanco, Horacio; Gluesenkamp, K.; Ally, Moonis Raza
2016-12-19
Here, the objective of this work is to simulate a single effct (SE) ammonia-water heat pump for domestic water heating, with innovative aspects for cycle simulation and eventual implementation. Seasonal temperature variations demand verfication of distillation column viability. For the given application and temperature ranges, it is found that some variables need to be controlled if the same column is to be used all year round. In addition, a number of simplifications are considered in this work: an advanced evaporator requireing minimal gas flow and surface area, subcooling at two crucial spots of the cycle and the viability of somemore » pump designs to assuage cavitation issues.« less
Chirp and temperature effects in parametric down conversion from crystals pumped at 800 nm
NASA Astrophysics Data System (ADS)
Sánchez-Lozano, X.; Wiechers, C.; Lucio, J. L.
2018-04-01
We consider spontaneous parametric down conversion from aperiodic poled crystals pumped at 800 nm. Our analyses account the effect of internal and external parameters, where, in the former, we include the crystal chirp and length, while in the latter temperature, also the pump chirp and other beam properties. The typical distribution produced is a pop-tab like structure in frequency-momentum space, and our results show that this system is a versatile light source, appropriated to manipulate the frequency and transverse momentum properties of the light produced. We briefly comment on the potential usefulness of the types of telecom wavelength light produced, in particular for quantum information applications.
Effect of Temperature Set-Back on Heat Pump Performance
1981-04-01
OF TEMPERATURE SET-BACK ON HEAT PUMP PERFORMANCE S. E. Kurtz SEPt 41981 Johns - Manville Sales Corporation S . Research and Development Center Ken...letter. The replies were catalogued according to their applicability. 13 -. 4 : "J.i Johns - Manville Sales Corporation Research & Development Center Ken...Caryl Harich De:nver Colorado 80217 July 28, 19ý8) Dear Sir: Johns - Manville Research and Development Center has been. engaged co study the potential
Thermal Performance of Capillary Pumped Loops Onboard Terra Spacecraft
NASA Technical Reports Server (NTRS)
Ku, Jentung; Ottenstein, Laura; Butler, Charles D.; Swanson, Theodore; Thies, Diane
2004-01-01
The Terra spacecraft is the flagship of NASA's Earth Science Enterprise. It provides global data on the state of atmosphere, land and oceans, as well as their interactions with solar radiation and one another. Three Terra instruments utilize Capillary Pumped Heat Transport System (CPHTS) for temperature control: Each CPHTS, consisting of two capillary pumped loops (CPLs) and several heat pipes and electrical heaters, is designed for instrument heat loads ranging from 25W to 264W. The working fluid is ammonia. Since the launch of the Terra spacecraft, each CPHTS has been providing a stable interface temperature specified by the instrument under all modes of spacecraft and instrument operations. The ability to change the CPHTS operating temperature upon demand while in service has also extended the useful life of one instrument. This paper describes the design and on-orbit performance of the CPHTS thermal systems.
Tunable CW diode-pumped Tm,Ho:YLiF4 laser operating at or near room temperature
NASA Technical Reports Server (NTRS)
Mcguckin, Brendan T. (Inventor); Menzies, Robert T. (Inventor)
1995-01-01
A conversion efficiency of 42% and slope efficiency of 60% relative to absorbed pump power are obtained from a continuous wave diode-pumped Tm,Ho:YLiF4 laser at 2 microns with output power of 84 mW at a crystal temperature of 275 K. The emission spectrum is etalon tunable over a range of7 nm (16.3/cm) centered on 2.067 microns with fine tuning capability of the transition frequency with crystal temperature at a measured rate of -0.03/(cm)K. The effective emission cross-section is measured to be 5 x 10(exp -21) cm squared. These and other aspects of the laser performance are disclosed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications. Single frequency output and frequency stabilization are achieved using an intracavity etalon in conjunction with an external reference etalon.
Lysaker, Paul H; George, Sunita; Chaudoin-Patzoldt, Kelly A; Pec, Ondrej; Bob, Petr; Leonhardt, Bethany L; Vohs, Jenifer L; James, Alison V; Wickett, Amanda; Buck, Kelly D; Dimaggio, Giancarlo
2017-11-01
Deficits in the ability to recognize and think about mental states are broadly understood to be a root cause of dysfunction in Borderline Personality Disorder (PD). This study compared the magnitude of those deficits relative to other forms of serious mental illness or psychiatric conditions. Assessments were performed using the metacognition assessment scale-abbreviated (MAS-A), emotion recognition using the Bell Lysaker Emotion Recognition Test and alexithymia using the Toronto Alexithymia Scale among adults with schizophrenia (n = 65), Borderline PD (n = 34) and Substance Use disorder without psychosis or significant Borderline traits (n = 32). ANCOVA controlling for age revealed the Borderline PD group had significantly greater levels of metacognitive capacity on the MAS-A than the schizophrenia group and significantly lower levels of metacognitive capacity than the Substance Use group. Multiple comparisons revealed the Borderline PD group had significantly higher self-reflectivity and awareness of the other's mind than the schizophrenia group but lesser mastery and decentration on the MAS-A than substance use group, after controlling for self-report of psychopathology and overall number of PD traits. The Borderline PD and Schizophrenia group had significantly higher levels of alexithymia than the substance use group. No differences were found for emotion recognition. Results suggest metacognitive functioning is differentially affected in different mental disorders. Published by Elsevier B.V.
Leontaridou, Maria; Urbisch, Daniel; Kolle, Susanne N; Ott, Katharina; Mulliner, Denis S; Gabbert, Silke; Landsiedel, Robert
2017-01-01
Test methods to assess the skin sensitization potential of a substance usually use threshold criteria to dichotomize continuous experimental read-outs into yes/no conclusions. The threshold criteria are prescribed in the respective OECD test guidelines and the conclusion is used for regulatory hazard assessment, i.e., classification and labelling of the substance. We can identify a borderline range (BR) around the classification threshold within which test results are inconclusive due to a test method's biological and technical variability. We quantified BRs in the prediction models of the non-animal test methods DPRA, LuSens and h-CLAT, and of the animal test LLNA, respectively. Depending on the size of the BR, we found that between 6% and 28% of the substances in the sets tested with these methods were considered borderline. When the results of individual non-animal test methods were combined into integrated testing strategies (ITS), borderline test results of individual tests also affected the overall assessment of the skin sensitization potential of the testing strategy. This was analyzed for the 2-out-of-3 ITS: Four out of 40 substances (10%) were considered borderline. Based on our findings we propose expanding the standard binary classification of substances into "positive"/"negative" or "hazardous"/"non-hazardous" by adding a "borderline" or "inconclusive" alert for cases where test results fall within the borderline range.
Borderline Personality Disorder in the perinatal period: early infant and maternal outcomes.
Blankley, Gaynor; Galbally, Megan; Snellen, Martien; Power, Josephine; Lewis, Andrew J
2015-12-01
This study examines pregnancy and early infant outcomes of pregnant women with a clinical diagnosis of Borderline Personality Disorder presenting for obstetric services to a major metropolitan maternity hospital in Victoria, Australia. A retrospective case review of pregnancy and early infant outcomes on 42 women who had been diagnosed with Borderline Personality Disorder via psychiatric assessment using DSM-IV-R criteria was undertaken. Outcomes were compared with a control group of 14,313 consisting of women and infants of non-affected women from the same hospital over the same period of time. Women presenting for obstetric services with a clinical diagnosis of Borderline Personality Disorder experienced considerable psychosocial impairment. They anticipated birth as traumatic and frequently requested early delivery. High comorbidity with substance abuse was found and high rates of referral to child protective services. Mothers with Borderline Personality Disorder were significantly more likely to have negative birth outcomes such as lowered Apgar scores, prematurity and special care nursery referral when compared with controls. These findings offer preliminary evidence to be considered by clinicians in developing treatments and services for the perinatal care of women with Borderline Personality Disorder and their infants. Further research is required in order to develop evidence informed clinical guidelines for the management of women with Borderline Personality Disorder and their infants. © The Royal Australian and New Zealand College of Psychiatrists 2015.
Goodman, Marianne; Tomas, Irene Alvarez; Temes, Christina M; Fitzmaurice, Garrett M; Aguirre, Blaise A; Zanarini, Mary C
2017-08-01
Prevalence data on self-mutilation and suicide attempts for adolescent borderline personality disorder (BPD) are currently not available. The purpose of this paper was to determine the frequency and methods of two forms of physically self-destructive acts (i.e. self-mutilation and suicide attempts) reported by adolescent borderline inpatients in one of the largest samples to date and to compare these results with a similarly diagnosed and assessed group of adult borderline inpatients. A total of 104 adolescent inpatients with BPD and 290 adult inpatients with BPD were interviewed about their lifetime history of physically self-destructive acts. The overall rates of self-mutilation (about 90%) and suicide attempts (about 75%) were similar during index admission for both adolescent and adult borderline patients. However, adolescents reported significantly higher rates of extreme levels of lifetime self-mutilation (e.g. >25 and >50 episodes) and cutting in particular, as compared with adult BPD. In contrast, borderline adults were significantly more likely to report a history of numerous (five or more) suicide attempts than adolescents with BPD. Self-mutilation and suicide attempts among adolescent borderline patients are prevalent and serious. Taken together, these results suggest that extreme levels of self-mutilation distinguish adolescent BPD from adults with BPD. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Kalpakci, Allison; Venta, Amanda; Sharp, Carla
2014-01-01
Central to most theories of borderline personality disorder (BPD) is the notion that the family environment interacts with genetically-based vulnerabilities to influence the development of BPD, with particular attention given to risk conferred by conflictual familial relations. However, the extent to which family conflict may relate to the development of BPD via related interpersonal beliefs is currently unknown. This study sought to test the hypothesis that the concurrent relation between conflictual family relations and borderline features in female college students is explained by beliefs associated with real or perceived unmet interpersonal needs (captured by Joiner's [2005] Interpersonal Psychological Theory, specifically thwarted belongingness and perceived burdensomeness). The sample included 267 female undergraduates ages 18-25 years (M = 20.86; SD = 1.80). Level of borderline personality features, unmet interpersonal needs, and family conflict were assessed. Bivariate analyses revealed significant relations between both thwarted belongingness and perceived burdensomeness, conflictual family relations, and borderline features. Multivariate analyses revealed that thwarted belongingness and perceived burdensomeness both mediated the relation between family conflict and borderline personality features, thus supporting a multiple mediation model. This cross-sectional study is a preliminary step towards confirming the broad theoretical hypothesis that conflictual family relations relate to beliefs about thwarted belongingness and perceived burdensomeness, which, in turn, relate to borderline personality pathology. Limitations and areas of future research are discussed.
Results of heating mode performance tests of a solar-assisted heat pump
NASA Technical Reports Server (NTRS)
Jones, C. B.; Smetana, F. O.
1979-01-01
The performance of a heat pump, utilizing 8.16 square meters of low-cost solar collectors as the evaporator in a Freon-114 refrigeration cycle, was determined under actual insolation conditions during the summer and fall of 1976. C.O.P.'s (coefficient of performance) greater than 3 were obtained with condensing temperatures around 78 C and evaporating temperatures around 27 C. Ambient temperatures were about 3 C above evaporating temperatures. Similar performance levels were obtained at other insolation and temperature conditions. Experience with the system has identified some component and system changes which should increase the obtainable C.O.P. to about 4.0. These are described along with the system's design rationale. The accumulated data are presented as an appendix.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wan, Yating; Li, Qiang; Lau, Kei May, E-mail: eekmlau@ust.hk
2016-07-04
Temperature characteristics of optically pumped micro-disk lasers (MDLs) incorporating InAs quantum dot active regions are investigated for on-chip light sources. The InAs quantum dot MDLs were grown on V-groove patterned (001) silicon, fully compatible with the prevailing complementary metal oxide-semiconductor technology. By combining the high-quality whispering gallery modes and 3D confinement of injected carriers in quantum dot micro-disk structures, we achieved lasing operation from 10 K up to room temperature under continuous optical pumping. Temperature dependences of the threshold, lasing wavelength, slope efficiency, and mode linewidth are examined. An excellent characteristic temperature T{sub o} of 105 K has been extracted.
System simulation for an untreated sewage source heat pump (USSHP) in winter
NASA Astrophysics Data System (ADS)
Qin, Na; Hao, Peng Z.
2017-01-01
The paper discusses the system characteristics of an untreated sewage source heat pump in winter. In this system, the sewage enters into the evaporator directly. The variable parameters to control the system contain the sewage temperature at evaporator inlet and the water temperature at condenser inlet. It is found that most parameters, except the condensation heat transfer coefficient, change in the form of sine wave the same as the sewage temperature at inlet. The heating load and consumed power are 12.9kW and 3.45kW when the sewage temperature at inlet is 13°C. COP is about 3.75 in the range of the sewage temperature at inlet of 12-13°C.
West, Robert G; Bína, David; Fuciman, Marcel; Kuznetsova, Valentyna; Litvín, Radek; Polívka, Tomáš
2018-05-01
We have applied femtosecond transient absorption spectroscopy in pump-probe and pump-dump-probe regimes to study energy transfer between fucoxanthin and Chl a in fucoxanthin-Chl a complex from the pennate diatom Phaeodactylum tricornutum. Experiments were carried out at room temperature and 77 K to reveal temperature dependence of energy transfer. At both temperatures, the ultrafast (<100 fs) energy transfer channel from the fucoxanthin S 2 state is active and is complemented by the second pathway via the combined S 1 /ICT state. The S 1 /ICT-Chl a pathway has two channels, the fast one characterized by sub-picosecond energy transfer, and slow having time constants of 4.5 ps at room temperature and 6.6 ps at 77 K. The overall energy transfer via the S 1 /ICT is faster at 77 K, because the fast component gains amplitude upon lowering the temperature. The pump-dump-probe regime, with the dump pulse centered in the spectral region of ICT stimulated emission at 950 nm and applied at 2 ps after excitation, proved that the S 1 and ICT states of fucoxanthin in FCP are individual, yet coupled entities. Analysis of the pump-dump-probe data suggested that the main energy donor in the slow S 1 /ICT-Chl a route is the S 1 part of the S 1 /ICT potential surface. Copyright © 2018 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Shulruf, Boaz; Jones, Phil; Turner, Rolf
2015-01-01
The determination of Pass/Fail decisions over Borderline grades, (i.e., grades which do not clearly distinguish between the competent and incompetent examinees) has been an ongoing challenge for academic institutions. This study utilises the Objective Borderline Method (OBM) to determine examinee ability and item difficulty, and from that…
ERIC Educational Resources Information Center
Hawes, David J.; Helyer, Rebekah; Herlianto, Eugene C.; Willing, Jonah
2013-01-01
This study tested if children and adolescents with high levels of borderline personality features (BPF) exhibit the same shame-prone self-concept previously found to characterize adults with borderline personality disorder (Rusch et al., 2007). Self-concept was indexed using the Implicit Association Test, in a community sample of…
ERIC Educational Resources Information Center
Gratz, Kim L.; Latzman, Robert D.; Tull, Matthew T.; Reynolds, Elizabeth K.; Lejuez, C. W.
2011-01-01
Most of the extant literature on borderline personality disorder has focused on the course, consequences, and correlates of this disorder among adults. However, little is known about childhood borderline personality (BP) features, or the factors associated with the emergence of BP pathology in childhood. A greater understanding of childhood BP…
ERIC Educational Resources Information Center
Schuppert, H. Marieke; Timmerman, Marieke E.; Bloo, Josephine; van Gemert, Tonny G.; Wiersema, Herman M.; Minderaa, Ruud B.; Emmelkamp, Paul M. G.; Nauta, Maaike H.
2012-01-01
Objective: To evaluate the effectiveness of Emotion Regulation Training (ERT), a 17-session weekly group training for adolescents with borderline personality disorder (BPD) symptoms. Method: One hundred nine adolescents with borderline traits (73% meeting the full criteria for BPD) were randomized to treatment as usual only (TAU) or ERT + TAU.…
ERIC Educational Resources Information Center
Treloar, Amanda Jane Commons; Lewis, Andrew J.
2009-01-01
This paper reviews the history of the recognition of borderline personality disorder as a clinical disorder, followed by a review of the contemporary practice of diagnosing borderline personality disorder in psychiatric settings. Many researchers have cautioned against the conflation of difficult patients with the diagnostic category of borderline…
ERIC Educational Resources Information Center
Wolke, Dieter; Schreier, Andrea; Zanarini, Mary C.; Winsper, Catherine
2012-01-01
Background: Abuse by adults has been reported as a potent predictor of borderline personality disorder (BPD). Unclear is whether victimisation by peers increases the risk of borderline personality symptoms. Method: The Avon Longitudinal Study of Parents and Children (ALSPAC) prospective, longitudinal observation study of 6050 mothers and their…
Subsurface Thermal Energy Storage for Improved Heating and Air Conditioning Efficiency
2016-11-21
This project involved a field demonstration of subsurface thermal energy storage for improving the geothermal heat pump air conditioning efficiency... geothermal heat pump systems, undesirable heating of the ground may occur. This demonstration was performed at the MCAS, Beaufort, SC, where several...buildings with geothermal heat pump systems were exhibiting excessively high ground loop temperatures. These buildings were retrofitted with dry fluid
Heater-induced altitude descent of the EISCAT UHF ion line enhancements: Observations and modelling
NASA Astrophysics Data System (ADS)
Ashrafi, M.; Kosch, M. J.; Honary, F.
2006-01-01
On 12 November 2001, artificial optical annuli were produced using the EISCAT high-frequency (HF) ionospheric heating facility. This unusual phenomenon was induced using O-mode transmissions at 5.423 MHz with 550 MW effective isotropic radiated power and the pump beam dipped 9° south of the zenith. The pump frequency corresponds to the fourth electron gyroharmonic frequency at 215 km altitude. The EISCAT UHF radar observed a persistent pump-induced enhancement in the ion line backscatter power near the HF reflection altitude. The optical and radar signatures of HF pumping started at ˜230 km and descended to ˜220 km within ˜60 s. This effect has been modelled using the solution to differential equations describing pump-induced electron temperature and density perturbations. The decrease in altitude of the ion line by ˜10 km and changes in electron density have been modelled. The results show that a maximum electron temperature enhancement of up to ˜5700 K can be achieved on average, which is not sufficient to explain the observed optical emissions.
NASA Astrophysics Data System (ADS)
Armitage, D. M.; Bacon, D. J.; Massey-Norton, J. T.; Miller, J. M.
1980-11-01
Groundwater is attractive as a potential low temperature energy source in residential space conditioning applications. When used in conjunction with a heat pump, ground water can serve as both a heat source and a heat sink. Major hydrogeologic aspects that affect system use include groundwater temperature and availability at shallow depths as these factors influence operational efficiency. Ground water quality is considered as it affects the performance and life expectancy of the water side heat exchanger. Environmental impacts related to groundwater heat pump system use are most influenced by water use and disposal methods. In general, recharge to the subsurface is recommended. Legal restrictions on system use are often stricter at the municipal and county levels than at state and federal levels. Computer simulations indicate that under a variety of climatologic conditions, groundwater heat pumps use less energy than conventional heating and cooling equipment. Life cycle cost comparisons with conventional equipment depend on alternative system choices and well cost options included in the groundwater heat pump system.
Isothermal pumping analysis for high-altitude tethered balloons
Kuo, Kirsty A.; Hunt, Hugh E. M.
2015-01-01
High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe. PMID:26543573
Isothermal pumping analysis for high-altitude tethered balloons.
Kuo, Kirsty A; Hunt, Hugh E M
2015-06-01
High-altitude tethered balloons have potential applications in communications, surveillance, meteorological observations and climate engineering. To maintain balloon buoyancy, power fuel cells and perturb atmospheric conditions, fluids could be pumped from ground level to altitude using the tether as a hose. This paper examines the pumping requirements of such a delivery system. Cases considered include delivery of hydrogen, sulfur dioxide (SO2) and powders as fluid-based slurries. Isothermal analysis is used to determine the variation of pressures and velocities along the pipe length. Results show that transport of small quantities of hydrogen to power fuel cells and maintain balloon buoyancy can be achieved at pressures and temperatures that are tolerable in terms of both the pipe strength and the current state of pumping technologies. To avoid solidification, transport of SO2 would require elevated temperatures that cannot be tolerated by the strength fibres in the pipe. While the use of particle-based slurries rather than SO2 for climate engineering can reduce the pipe size significantly, the pumping pressures are close to the maximum bursting pressure of the pipe.
Electrical pumping and tuning of exciton-polaritons in carbon nanotube microcavities
NASA Astrophysics Data System (ADS)
Graf, Arko; Held, Martin; Zakharko, Yuriy; Tropf, Laura; Gather, Malte C.; Zaumseil, Jana
2017-09-01
Exciton-polaritons are hybrid light-matter particles that form upon strong coupling of an excitonic transition to a cavity mode. As bosons, polaritons can form condensates with coherent laser-like emission. For organic materials, optically pumped condensation was achieved at room temperature but electrically pumped condensation remains elusive due to insufficient polariton densities. Here we combine the outstanding optical and electronic properties of purified, solution-processed semiconducting (6,5) single-walled carbon nanotubes (SWCNTs) in a microcavity-integrated light-emitting field-effect transistor to realize efficient electrical pumping of exciton-polaritons at room temperature with high current densities (>10 kA cm-2) and tunability in the near-infrared (1,060 nm to 1,530 nm). We demonstrate thermalization of SWCNT polaritons, exciton-polariton pumping rates ~104 times higher than in current organic polariton devices, direct control over the coupling strength (Rabi splitting) via the applied gate voltage, and a tenfold enhancement of polaritonic over excitonic emission. This powerful material-device combination paves the way to carbon-based polariton emitters and possibly lasers.
Prognostic Effect and Longitudinal Hemodynamic Assessment of Borderline Pulmonary Hypertension.
Assad, Tufik R; Maron, Bradley A; Robbins, Ivan M; Xu, Meng; Huang, Shi; Harrell, Frank E; Farber-Eger, Eric H; Wells, Quinn S; Choudhary, Gaurav; Hemnes, Anna R; Brittain, Evan L
2017-12-01
Pulmonary hypertension (PH) is diagnosed by a mean pulmonary arterial pressure (mPAP) value of at least 25 mm Hg during right heart catheterization (RHC). While several studies have demonstrated increased mortality in patients with mPAP less than that threshold, little is known about the natural history of borderline PH. To test the hypothesis that patients with borderline PH have decreased survival compared with patients with lower mPAP and frequently develop overt PH and to identify clinical correlates of borderline PH. Retrospective cohort study from 1998 to 2014 at Vanderbilt University Medical Center, comprising all patients undergoing routine RHC for clinical indication. We extracted demographics, clinical data, invasive hemodynamics, echocardiography, and vital status for all patients. Patients with mPAP values of 18 mm Hg or less, 19 to 24 mm Hg, and at least 25 mm Hg were classified as reference, borderline PH, and PH, respectively. Mean pulmonary arterial pressure. Our primary outcome was all-cause mortality after adjusting for clinically relevant covariates in a Cox proportional hazards model. Our secondary outcome was the diagnosis of overt PH in patients initially diagnosed with borderline PH. Both outcomes were determined prior to data analysis. We identified 4343 patients (mean [SD] age, 59 [15] years, 51% women, and 86% white) among whom the prevalence of PH and borderline PH was 62% and 18%, respectively. Advanced age, features of the metabolic syndrome, and chronic heart and lung disease were independently associated with a higher likelihood of borderline PH compared with reference patients in a logistic regression model. After adjusting for 34 covariates in a Cox proportional hazards model, borderline PH was associated with increased mortality compared with reference patients (hazard ratio, 1.31; 95% CI, 1.04-1.65; P = .001). The hazard of death increased incrementally with higher mPAP, without an observed threshold. In the 70 patients with borderline PH who underwent a repeated RHC, 43 (61%) had developed overt PH, with a median increase in mPAP of 5 mm Hg (interquartile range, -1 to 11 mm Hg; P < .001). Borderline PH is common in patients undergoing RHC and is associated with significant comorbidities, progression to overt PH, and decreased survival. Small increases in mPAP, even at values currently considered normal, are independently associated with increased mortality. Prospective studies are warranted to determine whether early intervention or closer monitoring improves clinical outcomes in these patients.
Gilbert, J W; Wolpin, B; Clancy, T; Wang, J; Mamon, H; Shinagare, A B; Jagannathan, J; Rosenthal, M
2017-09-01
Diagnostic imaging plays a critical role in the initial diagnosis and therapeutic monitoring of pancreatic adenocarcinoma. Over the past decade, the concept of 'borderline resectable' pancreatic cancer has emerged to describe a distinct subset of patients existing along the spectrum from resectable to locally advanced disease for whom a microscopically margin-positive (R1) resection is considered relatively more likely, primarily due to the relationship of the primary tumor with surrounding vasculature. This review traces the conceptual evolution of borderline resectability from a radiological perspective, including the debates over the key imaging criteria that define the thresholds between resectable, borderline resectable, and locally advanced or metastatic disease. This review also addresses the data supporting neoadjuvant therapy in this population and discusses current imaging practices before and during treatment. A growing body of evidence suggests that the borderline resectable group of patients may particularly benefit from neoadjuvant therapy to increase the likelihood of an ultimately margin-negative (R0) resection. Unfortunately, anatomic and imaging criteria to define borderline resectability are not yet universally agreed upon, with several classification systems proposed in the literature and considerable variance in institution-by-institution practice. As a result of this lack of consensus, as well as overall small patient numbers and lack of established clinical trials dedicated to borderline resectable patients, accurate evidence-based diagnostic categorization and treatment selection for this subset of patients remains a significant challenge. Clinicians and radiologists alike should be cognizant of evolving imaging criteria for borderline resectability given their profound implications for treatment strategy, follow-up recommendations, and prognosis. © The Author 2017. Published by Oxford University Press on behalf of the European Society for Medical Oncology. All rights reserved. For permissions, please email: journals.permissions@oup.com.
Tanaka, Shingo; Kaneko, Hidehiro; Kano, Hiroto; Matsuno, Shunsuke; Suzuki, Shinya; Takai, Hideaki; Otsuka, Takayuki; Uejima, Tokuhisa; Oikawa, Yuji; Nagashima, Kazuyuki; Kirigaya, Hajime; Sagara, Koichi; Yajima, Junji; Sawada, Hitoshi; Aizawa, Tadanori; Yamashita, Takeshi
2016-07-01
Low ankle-brachial index (ABI) is associated with increased mortality and an increased incidence of cardiovascular events. The purpose of this study was to investigate the value of borderline ABI in predicting clinical outcomes. The data were derived from the Shinken Database 2004-2012, from a single hospital-based cohort study (N = 19,994). ABI was measured in 5205 subjects; 4756 subjects whose ABI was 0.91-1.39 and having no history of peripheral artery disease were enrolled. The subjects were classified into two groups as follows: borderline ABI (0.91-1.00; n = 324) and normal ABI (1.01-1.39; n = 4432). Subjects in the borderline ABI group had more comorbidities, including diabetes mellitus, aortic disease, and stroke. Moreover, the borderline ABI group was associated with higher levels of hemoglobin A1c and brain natriuretic peptide, larger diameters of left atrium and left ventricle, and lower levels of estimated glomerular filtration rate and left ventricular ejection fraction. All-cause death and cardiovascular death occurred in 9.3% and 4.6% of subjects in the borderline ABI group, and in 2.0% and 0.8% of subjects in the normal ABI group, respectively. An adjusted Cox regression model showed that borderline ABI was associated with a higher incidence of all-cause death (hazard ratio [HR] 2.27, p = 0.005) and cardiovascular death (HR 3.47, p = 0.003). A borderline ABI was independently associated with worse clinical outcomes in relatively high risk population. Our data should be confirmed in larger populations including those with low risk profiles. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Keuroghlian, Alex S.; Frankenburg, Frances R.; Zanarini, Mary C.
2013-01-01
Background The interaction of borderline personality disorder (BPD) with physical health has not been well characterized. In this longitudinal study, we investigated the long-term relationship of chronic medical illnesses, health-related lifestyle choices, and health services utilization to recovery status in borderline patients over a decade of prospective follow-up. Method 264 borderline patients were interviewed concerning their physical health at 6-year follow-up in a longitudinal study of the course of BPD. This sample was then reinterviewed five times at two-year intervals over the next ten years. We defined recovery from BPD based on a Global Assessment of Functioning score of 61 or higher, which required BPD remission, one close relationship, and full-time competent and consistent work or school attendance. We controlled for potentially confounding effects of time-varying major depressive disorder. Results Never-recovered borderline patients were significantly more likely than ever-recovered borderline patients to have a medical syndrome, obesity, osteoarthritis, diabetes, urinary incontinence, or multiple medical conditions (p < 0.0063). They were also significantly more likely to report pack-per-day smoking, weekly alcohol use, no regular exercise, daily sleep medication use, or pain medication overuse (p < 0.0083). In addition, never-recovered borderline patients were significantly more likely than ever-recovered borderline patients to undergo a medical emergency room visit, medical hospitalization, X-ray, CT scan, or MRI scan (p < 0.0063). Conclusions Over a decade of prospective follow-up, failure to recover from BPD seems to be associated with a heightened risk of chronic medical illnesses, poor health-related lifestyle choices, and costly health services utilization. PMID:23856083
Performance Analysis of Air-to-Water Heat Pump in Latvian Climate Conditions
NASA Astrophysics Data System (ADS)
Kazjonovs, Janis; Sipkevics, Andrejs; Jakovics, Andris; Dancigs, Andris; Bajare, Diana; Dancigs, Leonards
2014-12-01
Strategy of the European Union in efficient energy usage demands to have a higher proportion of renewable energy in the energy market. Since heat pumps are considered to be one of the most efficient heating and cooling systems, they will play an important role in the energy consumption reduction in buildings aimed to meet the target of nearly zero energy buildings set out in the EU Directive 2010/31/EU. Unfortunately, the declared heat pump Coefficient of Performance (COP) corresponds to a certain outdoor temperature (+7 °C), therefore different climate conditions, building characteristics and settings result in different COP values during the year. The aim of this research is to investigate the Seasonal Performance factor (SPF) values of air-to-water heat pump which better characterize the effectiveness of heat pump in a longer selected period of time, especially during the winter season, in different types of residential buildings in Latvian climate conditions. Latvia has four pronounced seasons of near-equal length. Winter starts in mid-December and lasts until mid-March. Latvia is characterized by cold, maritime climate (duration of the average heating period being 203 days, the average outdoor air temperature during the heating period being 0.0 °C, the coldest five-day average temperature being -20.7 °C, the average annual air temperature being +6.2 °C, the daily average relative humidity being 79 %). The first part of this research consists of operational air-towater heat pump energy performance monitoring in different residential buildings during the winter season. The second part of the research takes place under natural conditions in an experimental construction stand which is located in an urban environment in Riga, Latvia. The inner area of this test stand, where air-to-water heat pump performance is analyzed, is 9 m2. The ceiling height is 3 m, all external wall constructions (U = 0.16 W/(m2K)) have ventilated facades. To calculate SPF, the experimental stand is equipped with sensors which provide measurements for electricity consumption and gained heat energy.
Food consumption as affect modulation in borderline personality.
Ambwani, Suman; Morey, Leslie C
2015-04-01
The present study examined relationships among negative affect, borderline personality features, and eating behavior through the experimental manipulation of mood. Undergraduate women (N = 307) completed a baseline mood assessment, viewed a 39-minute sad film either with or without concurrent food presentation, then completed a second mood assessment and questionnaires assessing personality and eating attitudes/behaviors. Women reporting more borderline personality features exhibited greater negative affect across time and were more reactive to the sad film. Food presentation appeared to have a small ameliorative effect on sadness and general negative affect. However, quantity of food consumption was associated with improvements in mood only for women reporting higher levels of borderline personality features. These data suggest that women with borderline personality characteristics may be at elevated risk for developing problems with binge eating, because consuming larger quantities of food appeared to have a tempering effect on their negative mood and feelings of sadness.
Sansone, Randy A; Sansone, Lori A
2015-01-01
Borderline personality disorder is a personality dysfunction that is characterized by disinhibition and impulsivity, which oftentimes manifest as self-regulation difficulties. Patients with this disorder have always been present in medical settings, but have been described as "difficult patients" rather than patients with borderline personality disorder. According to empirical findings, a number of behaviors and medical syndromes/diagnoses are suggestive of borderline personality disorder. Suggestive behaviors in the medical setting may include aggressive or disruptive behaviors, the intentional sabotage of medical care, and excessive healthcare utilization. Suggestive medical syndromes and diagnoses in the medical setting may include alcohol and substance misuse (including the abuse of prescription medications), multiple somatic complaints, chronic pain, obesity, sexual impulsivity, and hair pulling. While not all-inclusive or diagnostic, these behaviors and syndromes/diagnoses may invite further clinical evaluation of the patient for borderline personality disorder.
A Computer-Aided Distinction Method of Borderline Grades of Oral Cancer
NASA Astrophysics Data System (ADS)
Sami, Mustafa M.; Saito, Masahisa; Muramatsu, Shogo; Kikuchi, Hisakazu; Saku, Takashi
We have developed a new computer-aided diagnostic system for differentiating oral borderline malignancies in hematoxylin-eosin stained microscopic images. Epithelial dysplasia and carcinoma in-situ (CIS) of oral mucosa are two different borderline grades similar to each other, and it is difficult to distinguish between them. A new image processing and analysis method has been applied to a variety of histopathological features and shows the possibility for differentiating the oral cancer borderline grades automatically. The method is based on comparing the drop-shape similarity level in a particular manually selected pair of neighboring rete ridges. It was found that the considered similarity level in dysplasia was higher than those in epithelial CIS, of which pathological diagnoses were conventionally made by pathologists. The developed image processing method showed a good promise for the computer-aided pathological assessment of oral borderline malignancy differentiation in clinical practice.
The continuum between Bipolar Disorder and Borderline Personality Disorder.
Elisei, Sandro; Anastasi, Serena; Verdolini, Norma
2012-09-01
Several studies have been carried out regarding the possible overlap between Bipolar Disorder and borderline personality disorder. Up to now, it is not possible to provide a definitive picture. In fact, there is currently significant debate about the relationship between Borderline Personality Disorder and Bipolar Disorder. MEDLINE searches were performed to identify the latest studies of these disorders, considering psychodynamic aspects. Bipolar disorder and borderline personality disorder share common clinical features, namely affective instability and impulsivity which however differ in quality. Consequently, to better understand these aspects, it is necessary to trace the stages of childhood psychological development. It has been claimed that Bipolar Disorder Type II can be divided into two subtypes: one stable and functional between episodes and one unstable between episodes which is related to Borderline Personality Disorder. However, better diagnostic theories, psychiatrist's empathy and patience remain the essential tool to understand and to face human suffering.
SANTISTEBAN, DANIEL A.; MUIR, JOAN A.; MENA, MAITE P.; MITRANI, VICTORIA B.
2014-01-01
With the growing acceptance of the borderline personality disorder diagnosis for adolescents has come a need for specialized treatments for this challenging population. Further, because of the prominence of the family system during early and later adolescence, family treatments are particularly needed. The purpose of this article is to present the integrative borderline adolescent family therapy (I-BAFT) model that emerged from a National Institute on Drug Abuse–funded (Stage 1) treatment development and enhancement effort. I-BAFT integrates (a) key interventions from the family treatment of adolescent drug abuse (D. A. Santisteban et al., 2003; J. Szapocznik & W. Kurtines, 1989), (b) skills training shown effective with adults with borderline personality disorder (M. Linehan, 1993a) and adapted for adolescents, and (c) individual treatment interventions that promote motivation for treatment and enhance the integration of the 3 treatment components. PMID:25663719
Hydrodynamic performance and heat generation by centrifugal pumps.
Ganushchak, Y; van Marken Lichtenbelt, W; van der Nagel, T; de Jong, D S
2006-11-01
For over a century, centrifugal pumps (CP) have been used in various applications, from large industrial pumps to flow pumps for aquariums. However, the use of CP as blood pumps has a rather short history. Consequently, the hydraulic performance data for a blood CP are limited. The aim of our investigation was to study the hydraulic performance and the heat generation of three commercially available CP: Bio-Medicus Bio-Pump BP80 (Medtronic), Rotaflow (Jostra Medizintechnik), and DeltaStream DP2 (MEDOS Medizintechnik AQ). The study was performed using a circuit primed with a water-glycerin mixture with a dynamic viscosity of 0.00272 pa/s. Pressure-flow curves were obtained by a stepwise stagnation of the pump outlet or inlet. The temperature changes were observed using ThermaCAM SC2000 (Flir Systems). The pumps' performance in close to clinical conditions ('operating region') was analysed in this report. The 'operating region' in the case of the BP80 is positioned around the pressure-flow curve at a pump speed of 3000 rpm. In the case of the Rotaflow, the 'operating region' was between the pump pressure-flow curves at a speed of 3000 and 4000 rpm, and the DP2 was found between 7000 and 8000 rpm. The standard deviation of mean pressure through the pump was used to characterise the stability of the pump. In experiments with outlet stagnation, the BP80 demonstrated high negative association between flow and pressure variability (r = -0.68, p < 0.001). In experiments with the DP2, this association was positive (r = 0.68, p < 0.001). All pumps demonstrated significantly higher variability of pressure in experiments with inlet stagnation in comparison to the experiments with outlet stagnation. The rise of relative temperature in the inlet of a pump was closely related to the flow rate. The heating of fluid was more pronounced in the 'zero-flow' mode, especially in experiments with inlet stagnation. In summary, (1) the 'zero-flow' regime, which is described in the manuals of some commercially-available pumps, is the use of the pump outside the allowable operating region. It is potentially dangerous and should, therefore, never be used in clinical settings. (2) Using centrifugal pumps for kinetic-assisted venous return can only be performed safely when the negative pressure at the inlet of the pump is monitored continuously. The maximum allowable negative pressure has to be defined for each type of pump, and must be based on pump performance.
High pumping-power fiber combiner for double-cladding fiber lasers and amplifiers
NASA Astrophysics Data System (ADS)
Zheng, Jinkun; Zhao, Wei; Zhao, Baoyin; Li, Zhe; Chang, Chang; Li, Gang; Gao, Qi; Ju, Pei; Gao, Wei; She, Shengfei; Wu, Peng; Hou, Chaoqi; Li, Weinan
2018-03-01
A high pumping-power fiber combiner for backward pumping configurations is fabricated and demonstrated by manufacturing process refinement. The pump power handling capability of every pump fiber can extend to 600 W, corresponding to the average pump coupling efficiency of 94.83%. Totally, 2.67-kW output power with the beam quality factor M2 of 1.41 was obtained, using this combiner in the fiber amplifier experimental setup. In addition, the temperature of the splicing region was less than 50.0°C in the designed combiner under the action of circulating cooling water. The experimental results prove that the designed combiner is a promising integrated all-fiber device for multikilowatt continuous-wave fiber laser with excellent beam quality.
Recirculating 1-K-Pot for Pulse-Tube Cryostats
NASA Technical Reports Server (NTRS)
Paine, Christopher T.; Naylor, Bret J.; Prouve, Thomas
2013-01-01
A paper describes a 1-K-pot that works with a commercial pulse tube cooler for astrophysics instrumentation testbeds that require temperatures <1.7 K. Pumped liquid helium-4 cryostats were commonly used to achieve this temperature. However, liquid helium-4 cryostats are being replaced with cryostats using pulse tube coolers. The closed-cycle 1K-pot system for the pulse tube cooler requires a heat exchanger on the pulse tube, a flow restriction, pump-out line, and pump system that recirculates helium-4. The heat exchanger precools and liquefies helium- 4 gas at the 2.5 to 3.5 K pulse tube cold head. This closed-cycle 1-K-pot system was designed to work with commercially available laboratory pulse tube coolers. It was built using common laboratory equipment such as stainless steel tubing and a mechanical pump. The system is self-contained and requires only common wall power to operate. The lift of 15 mW at 1.1 K and base temperature of 0.97 K are provided continuously. The system can be scaled to higher heat lifts of .30 to 50 mW if desired. Ground-based telescopes could use this innovation to improve the efficiency of existing cryo
ERIC Educational Resources Information Center
Wood, Timothy J.; Humphrey-Murto, Susan M.; Norman, Geoffrey R.
2006-01-01
When setting standards, administrators of small-scale OSCEs often face several challenges, including a lack of resources, a lack of available expertise in statistics, and difficulty in recruiting judges. The Modified Borderline-Group Method is a standard setting procedure that compensates for these challenges by using physician examiners and is…
Ross, Donald R; Favero, Marcus
2002-01-01
The experience of many patients with borderline personality is intense and kaleidoscopic. These qualities may be represented in film in ways that reflect and convey their essential features that are less readily captured in words. Quentin Tarantino has produced a trilogy of films that bring to light and to life the borderline experience. We use these movies to illustrate and discuss five key borderline themes: the fluid nature of drive derivatives, the discontinuous experience of time and space, the coniflicted search for an idealized parent, antisocial distortions of the superego, and the organizing and stabilizing function of a central romantic fantasy.
Zanarini, Mary C; Frankenburg, Frances R; Reich, D Bradford; Fitzmaurice, Garrett M
2016-07-01
The purpose of this study was to determine the cumulative rates of 2- and 4-year remission, and the recurrences that follow them, of 24 symptoms of borderline personality disorder over 16 years of prospective follow-up. A total of 290 inpatients meeting rigorous criteria for borderline personality disorder and 72 axis II comparison subjects were assessed during their index admission using a series of semistructured diagnostic interviews. The same instruments were readministered at eight contiguous 2-year time periods. The 12 acute symptoms (e.g., self-mutilation, help-seeking suicide attempts) of borderline personality disorder were more likely to remit for a period of 2 years and for a period of 4 years than the 12 temperamental symptoms (e.g., chronic anger/frequent angry acts, intolerance of aloneness) of this disorder. They were also less likely to recur after a remission lasting 2 years or a remission lasting 4 years. Taken together, the symptoms of borderline personality disorder are quite fluid, with remissions and recurrences being common. However, the more clinically urgent acute symptoms of borderline personality disorder seem to have a better prognosis than the less turbulent temperamental symptoms of the disorder.
Zanarini, Mary C.; Frankenburg, Frances R.; Reich, D. Bradford; Fitzmaurice, Garrett M.
2016-01-01
Objective The purpose of this study was to determine the cumulative rates of two and four-year remission, and the recurrences that follow them, of 24 symptoms of borderline personality disorder over 16 years of prospective follow-up. Method 290 inpatients meeting rigorous criteria for borderline personality disorder and 72 axis II comparison subjects were assessed during their index admission using a series of semistructured diagnostic interviews. The same instruments were readministered at eight contiguous two-year time periods. Results The 12 acute symptoms (e.g., self-mutilation, help-seeking suicide attempts) of borderline personality disorder were more likely to remit for a period of two years and for a period of four years than the 12 temperamental symptoms (e.g., chronic anger/frequent angry acts, intolerance of aloneness) of this disorder. They were also less likely to recur after a remission lasting two years or a remission lasting four years. Conclusions Taken together, the symptoms of borderline personality disorder are quite fluid, with remissions and recurrences being common. However, the more clinically urgent acute symptoms of borderline personality disorder seem to have a better prognosis than the less turbulent temperamental symptoms of the disorder. PMID:26869248
Lyons-Ruth, Karlen; Bureau, Jean-Francois; Holmes, Bjarne; Easterbrooks, Ann; Brooks, Nancy Hall
2012-01-01
The primary objective was to assess whether prospectively observed quality of parent-child interaction in infancy and middle childhood contributed to the prediction of borderline symptoms and recurrent suicidality/self-injury in late adolescence. Adolescents (mean 19.9 years) from 56 families participating in a longitudinal study since infancy (retention rate 74%) were assessed on the SCID-II for symptoms of borderline personality disorder, including suicidality/self-injury. Early clinical risk was indexed by clinical referral to parent-infant services. Attachment security and parent-child interaction were assessed from videotape at 18 months and 8 years. Severity of childhood abuse was rated from interview and self-report measures. Maternal withdrawal in infancy was a significant predictor of both borderline symptoms and suicidality/self-injury in late adolescence. Disorganizedcontrolling child behavior at age 8 contributed independently to the prediction of borderline symptoms. The effect of maternal withdrawal was independent of, and additive to, variability explained by severity of childhood abuse. Borderline symptoms and suicidality/self-injury may be preceded developmentally by disturbed interactions as early as 18 months of age. A parent-child transactional model is proposed to account for the findings. PMID:23123044
Momeni Safarabad, Nahid; Asgharnejad Farid, Ali-Asghar; Gharraee, Banafsheh; Habibi, Mojtaba
2018-01-01
Objective: This study aimed at reporting the effect of the 3-phase model of eye movement desensitization and reprocessing in the treatment of a patient with borderline personality disorder. Method : A 33-year-old female, who met the DSM-IV-TR criteria for borderline personality disorder, received a 20-session therapy based on the 3-phase model of eye movement desensitization and reprocessing. Borderline Personality Disorder Checklist (BPD-Checklist), Dissociative Experience Scale (DES-II), Beck Depression Inventory-II-second edition (BDI-II), and Anxiety Inventory (BAI) were filled out by the patient at all treatment phases and at the 3- month follow- up. Results: According to the obtained results, the patient's pretest scores in all research tools were 161, 44, 37, and 38 for BPD-Checklist, DES-II, BDI-II, and BAI, respectively. After treatment, these scores decreased significantly (69, 14, 6 and 10 respectively). So, the patient exhibited improvement in borderline personality disorder, dissociative, depression and anxiety symptoms, which were maintained after the 3-month follow-up. Conclusion: The results supported the positive effect of phasic model of eye movement desensitization and reprocessing on borderline personality disorder.
[The relevance of sexuality in the treatment of borderline personality disorder].
Neeleman, A J F
2007-01-01
Although many articles about borderline personality disorder have been published over the last 25 years, sexuality has not received much attention. Sexual functioning may however be relevant for the treatment of this disorder. To find out from research reports, the literature and clinical practice whether they contain evidence of varying degrees of problematical sexuality in borderline patients, and if so, to make an inventory of the evidence. A literature search was conducted via PubMed and Psycinfo using the search terms 'borderline personality disorder', 'sexuality' and 'research'. In addition, the literature was searched manually. Only six empirical studies about the sexual functioning of patients with borderline personality disorder were found. The research findings provided information about patients' problems with regard to intimate and sexual relations. These problems related to heightened sexual impulsivity, reduced satisfaction, increased sexual boredom, greater preoccupation with sex, avoidance of sex and a range of other sexual complaints. In addition, there is evidence that homosexuality and vulnerability regarding gender identity occur more frequently in these patients. Helping to integrate love and sexuality with a suitable partner seems to be an important developmental assignment for persons assisting borderline patients.
Momeni Safarabad, Nahid; Asgharnejad Farid, Ali-Asghar; Gharraee, Banafsheh; Habibi, Mojtaba
2018-01-01
Objective: This study aimed at reporting the effect of the 3-phase model of eye movement desensitization and reprocessing in the treatment of a patient with borderline personality disorder. Method : A 33-year-old female, who met the DSM-IV-TR criteria for borderline personality disorder, received a 20-session therapy based on the 3-phase model of eye movement desensitization and reprocessing. Borderline Personality Disorder Checklist (BPD-Checklist), Dissociative Experience Scale (DES-II), Beck Depression Inventory-II-second edition (BDI-II), and Anxiety Inventory (BAI) were filled out by the patient at all treatment phases and at the 3- month follow- up. Results: According to the obtained results, the patient’s pretest scores in all research tools were 161, 44, 37, and 38 for BPD-Checklist, DES-II, BDI-II, and BAI, respectively. After treatment, these scores decreased significantly (69, 14, 6 and 10 respectively). So, the patient exhibited improvement in borderline personality disorder, dissociative, depression and anxiety symptoms, which were maintained after the 3-month follow-up. Conclusion: The results supported the positive effect of phasic model of eye movement desensitization and reprocessing on borderline personality disorder. PMID:29892320
Continuous two-wave lasing in microchip Nd : YAG lasers
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ievlev, Ivan V; Koryukin, Igor' V; Lebedeva, Yu S
2011-08-31
Simultaneous two-wave lasing was obtained in microchip end-pumped Nd:YAG lasers at the wavelengths of 1061.5 and 1064.17 nm at room temperature. Laser wave intensities were studied as functions of crystal temperature and pump power. The ranges of parameters were determined in which the two-wave lasing occurs and the reasons for such lasing were established. A model is suggested, which adequately describes the experimental results obtained. (control of radiation parameters)
NASA Technical Reports Server (NTRS)
Schoenfeld, Michael P.; Webster, Kenny L.; Pearson, Boise J.
2013-01-01
As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.
Reactor Simulator Integration and Testing
NASA Technical Reports Server (NTRS)
Schoenfield, M. P.; Webster, K. L.; Pearson, J. B.
2013-01-01
As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator (RxSim) test loop was designed and built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing were to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V because the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This Technical Memorandum summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained, which was lower than the predicted 750 K but 156 K higher than the cold temperature, indicating the design provided some heat regeneration. The annular linear induction pump tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.
Spatially resolved measurement of the core temperature in a high-power thulium fiber system
NASA Astrophysics Data System (ADS)
Walbaum, Till; Heinzig, Matthias; Beier, Franz; Liem, Andreas; Schreiber, Thomas; Eberhardt, Ramona; Tünnermann, Andreas
2016-03-01
We present measurements of the temperature increase inside the active fiber of a thulium fiber amplifier during high power operation. At a pump power of over 100 W at a wavelength of 793 nm, we measure the core temperature distribution along the first section of a large mode area (LMA) highly thulium doped active fiber by use of an optical backscatter reflectometer. A mode field adaptor is used to maintain single mode operation in the LMA fiber. An increase in temperature of over 100 K can be observed in spite of conductive cooling, located at the pumped fiber end and jeopardizing the fiber coating. The recoated splice can be clearly identified as the hottest fiber region. This allows us to estimate the maximum thermally acceptable pump power for this amplifier. We also observe that the temperature can be decreased by increasing the seed power, which is in agreement with theoretical predictions on the increase of cross relaxation efficiency by depletion of the upper laser level. This underlines the role of power scaling of the respective seed power of a thulium amplifier stage as a means of thermal management.
NASA Technical Reports Server (NTRS)
Kilbane, J.; Polzin, K. A.
2014-01-01
An annular linear induction pump (ALIP) that could be used for circulating liquid-metal coolant in a fission surface power reactor system is modeled in the present work using the computational COMSOL Multiphysics package. The pump is modeled using a two-dimensional, axisymmetric geometry and solved under conditions similar to those used during experimental pump testing. Real, nonlinear, temperature-dependent material properties can be incorporated into the model for both the electrically-conducting working fluid in the pump (NaK-78) and structural components of the pump. The intricate three-phase coil configuration of the pump is implemented in the model to produce an axially-traveling magnetic wave that is qualitatively similar to the measured magnetic wave. The model qualitatively captures the expected feature of a peak in efficiency as a function of flow rate.
IEA HPT ANNEX 41 – Cold climate heat pumps: US country report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Groll, Eckhard A.; Baxter, Van D.
In 2012 the International Energy Agency (IEA) Heat Pump Programme (now the Heat Pump Technologies (HPT) program) established Annex 41 to investigate technology solutions to improve performance of heat pumps for cold climates. Four IEA HPT member countries are participating in the Annex – Austria, Canada, Japan, and the United States (U.S.). The principal focus of Annex 41 is on electrically driven air-source heat pumps (ASHP) since that system type has the lowest installation cost of all heat pump alternatives. They also have the most significant performance challenges given their inherent efficiency and capacity issues at cold outdoor temperatures. Availabilitymore » of ASHPs with improved low ambient performance would help bring about a much stronger heat pump market presence in cold areas, which today rely predominantly on fossil fuel furnace heating systems.« less
DIRECT CURRENT ELECTROMAGNETIC PUMP
Barnes, A.H.
1957-11-01
An improved d-c electromagnetic pump is presented in which the poles, and consequently the magetic gap at the poles, are tapered to be wider at the upstream end. In addition, the cross section of the tube carryiQ the liquid metal is tapered so that the velocity of the pumped liquid increases in the downstream direction at a rate such that the counter-induced voltage in the liquid metal remains constant as it traverses the region between the poles. This configuration compensates for the distortion of the magnetic field caused by the induced voltage that would otherwise result in the lowering of the pumping capacity. This improved electromagnetic pump as practical application in the pumping of liquid metal coolants for nuclear reactors where conventional positive displacement pumps have proved unsatisfactory due to the high temperatures and the corrosive properties of the liquid metals involved.
Design of a Mechanical NaK Pump for Fission Space Power
NASA Technical Reports Server (NTRS)
Mireles, Omar R.; Bradley, David E.; Godfroy, Thomas
2011-01-01
Alkali liquid metal cooled fission reactor concepts are under development for spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid, which has specific pumping requirements. Traditionally, electromagnetic linear induction pumps have been used to provide the required flow and pressure head conditions for NaK systems but they can be limited in performance, efficiency, and number of available vendors. The objective of the project was to develop a mechanical NaK centrifugal pump that takes advantages of technology advances not available in previous liquid metal mechanical pump designs. This paper details the design, build, and performance test of a mechanical NaK pump developed at NASA Marshall Space Flight Center. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.
GEO3D - Three-Dimensional Computer Model of a Ground Source Heat Pump System
James Menart
2013-06-07
This file is the setup file for the computer program GEO3D. GEO3D is a computer program written by Jim Menart to simulate vertical wells in conjunction with a heat pump for ground source heat pump (GSHP) systems. This is a very detailed three-dimensional computer model. This program produces detailed heat transfer and temperature field information for a vertical GSHP system.
Evaluation of System Architectures for the Army Aviation Ground Power Unit
2014-12-01
this state of operation induces wear that reduces pump life. Variable capacity control methods using a constant displacement pump are drive speed...options for use with constant displacement pumps, the fluid or magnetic coupling devices are the most attractive. Variable frequency control cannot...compressor prior to the combustor. The cmTent system turbine exhaust temperature controls to 1250°F, much higher than the compressor exit
Pumped two-phase heat transfer loop
NASA Technical Reports Server (NTRS)
Edelstein, Fred
1988-01-01
A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes several independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.
Pumped two-phase heat transfer loop
NASA Technical Reports Server (NTRS)
Edelstein, Fred (Inventor)
1987-01-01
A pumped loop two-phase heat transfer system, operating at a nearly constant temperature throughout, includes a plurality of independently operating grooved capillary heat exchanger plates supplied with working fluid through independent flow modulation valves connected to a liquid supply line, a vapor line for collecting vapor from the heat exchangers, a condenser between the vapor and the liquid lines, and a fluid circulating pump between the condenser and the heat exchangers.
Park, Hyun Jeong; Choi, Byung Ihn; Lee, Eun Sun; Park, Sung Bin; Lee, Jong Beum
2017-06-01
Rapid advances in liver imaging have improved the evaluation of hepatocarcinogenesis and early diagnosis and treatment of hepatocellular carcinoma (HCC). In this situation, detection of early-stage HCC in its development is important for the improvement of patient survival and optimal treatment strategies. Because early HCCs are considered precursors of progressed HCC, precise differentiation between a dysplastic nodule (DN), especially a high-grade DN, and early HCC is important. In clinical practice, these nodules are frequently called "borderline hepatic nodules." This article discusses radiological and pathological characteristics of these borderline hepatic nodules and offers an understanding of multistep hepatocarcinogenesis by focusing on the descriptions of the imaging changes in the progression of DN and early HCC. Detection and accurate diagnosis of borderline hepatic nodules are still a challenge with contrast enhanced ultrasonography, CT, and MRI with extracellular contrast agents. However, gadoxetic acid-enhanced MRI may be useful for improving the diagnosis of these borderline nodules. Since there is a net effect of incomplete neoangiogenesis and decreased portal venous flow in the early stage of hepatocarcinogenesis, borderline hepatic nodules commonly show iso- or hypovascularity. Therefore, precise differentiation of these nodules remains a challenging issue. In MRI using hepatobiliary contrast agents, signal intensity of HCCs on hepatobiliary phase (HBP) is regarded as a potential imaging biomarker. Borderline hepatic nodules are seen as nonhypervascular and hypointense nodules on the HBP, which is important for predicting tumor behavior and determining appropriate therapeutic strategies.
Nouwens, P J G; Smulders, N B M; Embregts, P J C M; van Nieuwenhuizen, C
2017-12-01
Among persons with a mild intellectual disability or borderline intellectual functioning, differences in their characteristics imply that a differentiated approach is required to meet their needs. This retrospective study examined whether the history of support/treatment programs and the type of healthcare providers involved matched the specific support needs of persons with a mild intellectual disability or borderline intellectual functioning. Five (previously identified) profiles of persons with a mild intellectual disability or borderline intellectual functioning were used to investigate to what extent the support needs of this group had been met. For the 250 persons with mild intellectual disability or borderline intellectual functioning who matched these five profiles, data were collected retrospectively from their case files. Persons with mild intellectual disability or borderline intellectual functioning received a very similar amount and type of support/treatment programs. Differences between the profiles were found for non-verbal therapy, residential treatment and contacts with social work. Regarding the type of healthcare providers involved, differences between the profiles emerged for specialised intellectual disability services, youth services and specialised addiction services. The support programs for a heterogeneous population of persons with mild intellectual disability or borderline intellectual functioning seem to be suboptimal, indicating that more differentiation is required in the services offered to these individuals. © 2017 MENCAP and International Association of the Scientific Study of Intellectual and Developmental Disabilities and John Wiley & Sons Ltd.
Herpertz, Sabine C; Bertsch, Katja
2015-09-01
Borderline personality disorder is characterized by three domains of dysfunction: affect dysregulation, behavioral dyscontrol, and interpersonal hypersensitivity. Interpersonal hypersensitivity is associated with a (pre)attentive bias toward negative social information and, on the level of the brain, enhanced bottom-up emotion generation, while affect dysregulation results from abnormal top-down processes. Additionally, the problems of patients with borderline personality disorder in interpersonal functioning appear to be related to alterations in the (social) reward and empathy networks. There is increasing evidence that the oxytocinergic system may be involved in these domains of dysfunction and may thus contribute to borderline psychopathology and even open new avenues for targeted pharmacotherapeutic approaches. From studies in healthy and clinical subjects (including first studies with borderline personality disorder patients), the authors provide a conceptual framework for future research in borderline personality disorder that is based on oxytocinergic modulation of the following biobehavioral mechanisms: 1) the brain salience network favoring adaptive social approach behavior, 2) the affect regulation circuit normalizing top-down processes, 3) the mesolimbic circuit improving social reward experiences, and 4) modulating brain regions involved in cognitive and emotional empathy. In addition, preliminary data point to interactions between the oxytocin and cannabinoid system, with implications for pain processing. These mechanisms, which the authors believe to be modulated by oxytocin, may not be specific for borderline personality disorder but rather may be common to a host of psychiatric disorders in which disturbed parent-infant attachment is a major etiological factor.
Nelson, David A; Coyne, Sarah M; Swanson, Savannah M; Hart, Craig H; Olsen, Joseph A
2014-08-01
Crick, Murray-Close, and Woods (2005) encouraged the study of relational aggression as a developmental precursor to borderline personality features in children and adolescents. A longitudinal study is needed to more fully explore this association, to contrast potential associations with physical aggression, and to assess generalizability across various cultural contexts. In addition, parenting is of particular interest in the prediction of aggression or borderline personality disorder. Early aggression and parenting experiences may differ in their long-term prediction of aggression or borderline features, which may have important implications for early intervention. The currrent study incorporated a longitudinal sample of preschool children (84 boys, 84 girls) living in intact, two-parent biological households in Voronezh, Russia. Teachers provided ratings of children's relational and physical aggression in preschool. Mothers and fathers also self-reported their engagement in authoritative, authoritarian, permissive, and psychological controlling forms of parenting with their preschooler. A decade later, 70.8% of the original child participants consented to a follow-up study in which they completed self-reports of relational and physical aggression and borderline personality features. The multivariate results of this study showed that preschool relational aggression in girls predicted adolescent relational aggression. Preschool aversive parenting (i.e., authoritarian, permissive, and psychologically controlling forms) significantly predicted aggression and borderline features in adolescent females. For adolescent males, preschool authoritative parenting served as a protective factor against aggression and borderline features, whereas authoritarian parenting was a risk factor for later aggression.
Long-term animal experiments with an intraventricular axial flow blood pump.
Yamazaki, K; Kormos, R L; Litwak, P; Tagusari, O; Mori, T; Antaki, J F; Kameneva, M; Watach, M; Gordon, L; Mukuo, H; Umezu, M; Tomioka, J; Outa, E; Griffith, B P; Koyanagai, H
1997-01-01
A miniature intraventricular axial flow blood pump (IVAP) is undergoing in vivo evaluation in calves. The IVAP system consists of a miniature (phi 13.9 mm) axial flow pump that resides within the left ventricular (LV) chamber and a brushless DC motor. The pump is fabricated from titanium alloy, and the pump weight is 170 g. It produces a flow rate of over 5 L/min against 100 mmHg pressure at 9,000 rpm with an 8 W total power consumption. The maximum total efficiency exceeds 17%. A purged lip seal system is used in prototype no. 8, and a newly developed "Cool-Seal" (a low temperature mechanical seal) is used in prototype no. 9. In the Cool-Seal system, a large amount of purge flow is introduced behind the seal faces to augment convective heat transfer, keeping the seal face temperature at a low level for prevention of heat denaturation of blood proteins. The Cool-Seal system consumes < 10 cc purge fluid per day and has greatly extended seal life. The pumps were implanted in three calves (26, 30, and 168 days of support). The pump was inserted through a left thoracotomy at the fifth intercostal space. Two pursestring sutures were placed on the LV apex, and the apex was cored with a myocardial punch. The pump was inserted into the LV with the outlet cannula smoothly passing through the aortic valve without any difficulty. Only 5 min elapsed between the time of chest opening and initiation of pumping. Pump function remained stable throughout in all experiments. No cardiac arrhythmias were detected, even at treadmill exercise tests. The plasma free hemoglobin level remained in the acceptable range. Post mortem examination did not reveal any interference between the pump and the mitral apparatus. No major thromboembolism was detected in the vital organs in Cases 1 or 2, but a few small renal infarcts were detected in Case 3.
End-pumped Nd:YVO4 laser with reduced thermal lensing via the use of a ring-shaped pump beam.
Lin, Di; Andrew Clarkson, W
2017-08-01
A simple approach for alleviating thermal lensing in end-pumped solid-state lasers using a pump beam with a ring-shaped intensity distribution to decrease the radial temperature gradient is described. This scheme has been implemented in a diode-end-pumped Nd:YVO 4 laser yielding 14 W of TEM 00 output at 1.064 μm with a corresponding slope efficiency of 53% and a beam propagation factor (M 2 ) of 1.08 limited by available pump power. By comparison, the same laser design with a conventional quasi-top-hat pump beam profile of approximately equal radial extent yielded only 9 W of output before the power rolled over due to thermal lensing. Further investigation with the aid of a probe beam revealed that the thermal lens power was ∼30% smaller for the ring-shaped pump beam compared to the quasi-top-hat beam. The implications for further power scaling in end-pumped laser configurations are considered.
Control methods and systems for indirect evaporative coolers
Woods, Jason; Kozubal, Erik
2015-09-22
A control method for operating an indirect evaporative cooler to control temperature and humidity. The method includes operating an airflow control device to provide supply air at a flow rate to a liquid desiccant dehumidifier. The supply air flows through the dehumidifier and an indirect evaporative cooler prior to exiting an outlet into a space. The method includes operating a pump to provide liquid desiccant to the liquid desiccant dehumidifier and sensing a temperature of an airstream at the outlet of the indirect evaporative cooler. The method includes comparing the temperature of the airstream at the outlet to a setpoint temperature at the outlet and controlling the pump to set the flow rate of the liquid desiccant. The method includes sensing space temperature, comparing the space temperature with a setpoint temperature, and controlling the airflow control device to set the flow rate of the supply air based on the comparison.
Heat pump/refrigerator using liquid working fluid
Wheatley, John C.; Paulson, Douglas N.; Allen, Paul C.; Knight, William R.; Warkentin, Paul A.
1982-01-01
A heat transfer device is described that can be operated as a heat pump or refrigerator, which utilizes a working fluid that is continuously in a liquid state and which has a high temperature-coefficient of expansion near room temperature, to provide a compact and high efficiency heat transfer device for relatively small temperature differences as are encountered in heating or cooling rooms or the like. The heat transfer device includes a pair of heat exchangers that may be coupled respectively to the outdoor and indoor environments, a regenerator connecting the two heat exchangers, a displacer that can move the liquid working fluid through the heat exchangers via the regenerator, and a means for alternately increasing and decreasing the pressure of the working fluid. The liquid working fluid enables efficient heat transfer in a compact unit, and leads to an explosion-proof smooth and quiet machine characteristic of hydraulics. The device enables efficient heat transfer as the indoor-outdoor temperature difference approaches zero, and enables simple conversion from heat pumping to refrigeration as by merely reversing the direction of a motor that powers the device.
Monitoring artificially stimulated fluid movement in the Cretaceous Dakota aquifer, western Kansas
Macfarlane, P.A.; Forster, A.; Merriam, D.F.; Schrotter, J.; Healey, J.M.
2002-01-01
Aquifer properties can be evaluated by monitoring artificially stimulated fluid movements between wells, if the fluid is heated. Changes in the temperature profile recorded in observation wells indicate the flow path of the heated fluid, which in effect acts as a tracer. A fluid-flow experiment in the Cretaceous Dakota Formation at the Hodgeman County site, west-central Kansas, demonstrated the advantage of using the distributed optical-fiber temperature sensing method for monitoring transient temperature conditions in his hydrological application. The fluid flow in the aquifer was increased by producing water from a pumping well and injecting heated water in an injection well 13 m (43 ft) distant from the pumping well. The time-temperature series data obtained and compared with results from previous pumping tests point to interwell heterogeneity of the aquifer and to a zone in the sandstone aquifer of high hydraulic conductivity. However, the experiment would have allowed further clarification of aquifer heterogeneity and thermal properties if at least one observation well had been present between the injection and production wells.
Reactor Simulator Testing Overview
NASA Technical Reports Server (NTRS)
Schoenfeld, Michael P.
2013-01-01
OBJECTIVE: Integrated testing of the TDU components TESTING SUMMARY: a) Verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. b) Thermal test heat regeneration design aspect of a cold trap purification filter. c) Pump performance test at pump voltages up to 150 V (targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V). TESTING HIGHLIGHTS: a) Gas and vacuum ground support test equipment performed effectively for NaK fill, loop pressurization, and NaK drain operations. b) Instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. c) Cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. d) ALIP produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.
van Heeswijk, Marijke; Cox, Stephen E.; Huffman, Raegan L.; Curran, Christopher A.
2008-01-01
The Lower and Combined Aquifers of the Eastbank Aquifer system, located in a river-terrace deposit along the Columbia River near Rocky Reach Dam, Washington, are primarily recharged by the Columbia River and provide water to the Eastbank Hatchery and the regional water system servicing the cities of Wenatchee, East Wenatchee, and parts of unincorporated Chelan and Douglas Counties. In 2006, mean annual pumpage from the aquifers by the hatchery and regional water system was about 43 and 16 cubic feet per second, respectively. Reportedly, temperatures of ground water pumped by the hatchery have been increasing, thereby making water potentially too warm for salmonid fish production. An evaluation of hourly ground-water and river temperatures from January 1991 through August 2007 indicates increasing interannual trends in temperatures in most of the Lower and Combined Aquifers from 1999 through 2006 that correspond to increasing trends in the annual mean and annual maximum river temperatures during the same period of 0.07 and 0.17?C per year, respectively. There were no trends in the annual minimum river temperatures from 1999 through 2006, and there were no trends in the annual minimum, mean, and maximum river temperatures from 1991 through 1998 and from 1991 through 2007. Increases in river temperatures from 1999 through 2006 are within the natural variability of the river temperatures. Most of the Lower and Combined Aquifers reached thermal equilibrium?defined by constant time lags between changes in river temperatures and subsequent changes in ground-water temperatures?during 1991?98. The only exceptions are the Combined Aquifer north of the well field of the regional water system, which had not reached thermal equilibrium by 2006, and the Lower Aquifer west of the well fields of the hatchery and the regional water system, which reached thermal equilibrium prior to 1991. Because most of the Lower and Combined Aquifers were in thermal equilibrium from 1999 through 2006 and seasonal pumpage patterns were relatively stable, reported trends of increasing temperatures of water pumped by the hatchery well field are most likely explained by increasing trends in river temperatures. Most of the water pumped by the hatchery well field recharges in an area west to southwest of the well field about 2 months prior to the time it is pumped from the aquifer. The northern extent of the hatchery well field may pump some colder water from a bedrock depression to the north and west of the well field. The conceptual model of hydrologic and thermal conditions is supported by analyses of historical water temperatures, water-level data collected on July 18, 2007, and dissolved-constituent and bacterial concentrations in samples collected on August 20?22, 2007.
Performance of a solar augmented heat pump
NASA Astrophysics Data System (ADS)
Bedinger, A. F. G.; Tomlinson, J. J.; Reid, R. L.; Chaffin, D. J.
Performance of a residential size solar augmented heat pump is reported for the 1979-1980 heating season. The facility located in Knoxville, Tennessee, has a measured heat load coefficient of 339.5 watt/C (644 BTU/hr- F). The solar augmented heat pump system consists of 7.4 cu m of one inch diameter crushed limestone. The heat pump is a nominal 8.8 KW (2 1/2 ton) high efficiency unit. The system includes electric resistance heaters to give the option of adding thermal energy to the pebble bed storage during utility off-peak periods, thus offering considerable load management capability. A 15 KW electric resistance duct heater is used to add thermal energy to the pebble bin as required during off-peak periods. Hourly thermal performance and on site weather data was taken for the period November 1, 1979, to April 13, 1980. Thermal performance data consists of heat flow summations for all modes of the system, pebble bed temperatures, and space temperature. Weather data consists of dry bulb temperature, dew point temperature, total global insolation (in the plane of the collector), and wind speed and direction. An error analysis was performed and the least accurate of the measurements was determined to be the heat flow at 5%. Solar system thermal performance factor was measured to be 8.77. The heat pump thermal performance factor was 1.64. Total system seasonal performance factor was measured to be 1.66. Using a modified version of TRNSYS, the thermal performance of this system was simulated. When simulation results were compared with data collected onsite, the predicted heat flow and power consumption generally were within experimental accuracy.
Blanco, J.M.; Long, J.A.; Gee, G.; Donoghue, A.M.; Wildt, D.E.
2008-01-01
Potential factors influencing sperm survival under hypertonic conditions were evaluated in the Sandhill crane (Grus canadensis) and turkey (Meleagridis gallopavo). Sperm osmotolerance (300-3000 mOsm/kg) was evaluated after: (1) equilibration times of 2, 10, 45 and 60 min at 4 ?C versus 21 ?C; (2) pre-equilibrating with dimethylacetamide (DMA) or dimethylsulfoxide (Me2SO) at either 4 ?C or 21 ?C; and (3) inhibition of the Na+/K+ and the Na+/H+ antiporter membrane ionic pumps. Sperm viability was assessed using the eosin-nigrosin live/dead stain. Species-specific differences occurred in response to hypertonic conditions with crane sperm remaining viable under extreme hypertonicity (3000 mOsm/kg), whereas turkey sperm viability was compromised with only slightly hypertonic (500 mOsm/kg) conditions. The timing of spermolysis under hypertonic conditions was also species-specific, with a shorter interval for turkey (2 min) than crane (10 min) sperm. Turkey sperm osmotolerance was slightly improved by lowering the incubation temperature from 21 to 4 ?C. Pre-equilibrating sperm with DMA reduced the incidence of hypertonic spermolysis only in the crane, at both room and refrigeration temperature. Inhibiting the Na+/K+ and the Na+/H+ antiporter membrane ion pumps did not impair resistance of crane and turkey spermatozoa to hypertonic stress; pump inhibition actually increased turkey sperm survival compared to control sperm. Results demonstrate marked species specificity in osmotolerance between crane and turkey sperm, as well as in the way temperature and time of exposure affect sperm survival under hypertonic conditions. Differences are independent of the role of osmotic pumps in these species.
Refrigeration system with a compressor-pump unit and a liquid-injection desuperheating line
Gaul, Christopher J.
2001-01-01
The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigeration system that includes an expansion device, an evaporator, a compressor, a condenser, and a liquid pump between the condenser and the expansion device. The liquid pump improves efficiency of the refrigeration system by increasing the pressure of, thus subcooling, the liquid refrigerant delivered from the condenser to the expansion device. The liquid pump and the compressor are driven by a single driving device and, in this regard, are coupled to a single shaft of a driving device, such as a belt-drive, an engine, or an electric motor. While the driving device may be separately contained, in a preferred embodiment, the liquid pump, the compressor, and the driving device (i.e., an electric motor) are contained within a single sealable housing having pump and driving device cooling paths to subcool liquid refrigerant discharged from the liquid pump and to control the operating temperature of the driving device. In another aspect of the present invention, a liquid injection assembly is included in a refrigeration system to divert liquid refrigerant from the discharge of a liquid pressure amplification pump to a compressor discharge pathway within a compressor housing to desuperheat refrigerant vapor to the saturation point within the compressor housing. The liquid injection assembly includes a liquid injection pipe with a control valve to meter the volume of diverted liquid refrigerant. The liquid injection assembly may also include a feedback controller with a microprocessor responsive to a pressure sensor and a temperature sensor both positioned between the compressor to operate the control valve to maintain the refrigerant at or near saturation.
Ductless Mini-Split Heat Pump Comfort Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, K.; Sehgal, N.; Akers, C.
2013-03-01
Field tests were conducted in two homes in Austin, TX, to evaluate the comfort performance of ductless minisplit heat pumps (DMSHPs), measuring temperature and relative humidity measurements in four rooms in each home before and after retrofitting a central HVAC system with DMSHPs.
Ductless Mini-Split Heat Pump Comfort Evaluation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roth, K.; Sehgal, N.; Akers, C.
2013-03-01
Field tests were conducted in two homes in Austin, TX to evaluate the comfort performance of ductless mini-split heat pumps (DMSHPs), measuring temperature and relative humidity measurements in four rooms in each home before and after retrofitting a central HVAC system with DMSHPs.
p14 expression differences in ovarian benign, borderline and malignant epithelial tumors.
Cabral, Vinicius Duarte; Cerski, Marcelle Reesink; Sa Brito, Ivana Trindade; Kliemann, Lucia Maria
2016-10-22
Abnormalities in tumor suppressors p14, p16 and p53 are reported in several human cancers. In ovarian epithelial carcinogenesis, p16 and p53 show higher immunohistochemical staining frequencies in malignant tumors and are associated with poor prognoses. p14 was only analyzed in carcinomas, with conflicting results. There are no reports on its expression in benign and borderline tumors. This study aims to determine p14, p16 and p53 expression frequencies in ovarian benign, borderline and malignant tumors and their associations with clinical parameters. A cross-sectional study utilizing immunohistochemistry was performed on paraffin-embedded ovarian epithelial tumor samples. Clinical data were collected from medical records. Fisher's exact test and the Bonferroni correction were performed for frequency associations. Survival comparisons utilized Kaplan-Meier and log rank testing. Associations were considered significant when p < 0.05. p14 absent expression was associated with malignant tumors (60 % positive) (p = 0.000), while 93 % and 94 % of benign and borderline tumors, respectively, were positive. p16 was positive in 94.6 % of carcinomas, 75 % of borderline and 45.7 % of benign tumors (p = 0.000). p53 negative staining was associated with benign tumors (2.9 % positive) (p = 0.016) but no difference was observed between borderline (16.7 %) and malignant tumors (29.7 %) (p = 0.560). No associations were found between expression rates, disease-free survival times or clinical variables. Carcinoma subtypes showed no difference in expression. This is the first description of p14 expression in benign and borderline tumors. It remains stable in benign and borderline tumors, while carcinomas show a significant absence of staining. This may indicate that p14 abnormalities occur later in carcinogenesis. p16 and p53 frequencies increase from benign to borderline and malignant tumors, similarly to previous reports, possibly reflecting the accumulation of inactive mutant protein. The small sample size may have prevented statistically significant survival analyses and clinical correlations. Future studies should investigate genetic abnormalities in p14 coding sequences and include all types of ovarian epithelial tumors. Bigger sample sizes may be needed for significant associations.
Phyllodes tumours of the breast: retrospective analysis of a University Hospital's experience.
Toh, Y F; Cheah, P L; Looi, L M; Teoh, K H; Tan, P H
2016-04-01
Taking cognizance of the purported variation of phyllodes tumours in Asians compared with Western populations, this study looked at phyllodes tumours of the breast diagnosed at the Department of Pathology, University of Malaya Medical Centre over an 8-year period with regards to patient profiles, tumour parameters, treatment offered and outcome. Sixty-four new cases of phyllodes tumour were diagnosed during the period, however only 30 (21 benign, 4 borderline and 5 malignant) finally qualified for entry into the study. These were followed-up for 4-102 months (average = 41.7 months). Thirteen cases (8 benign, 3 borderline, 2 malignant) were Chinese, 9 (all benign) Malay, 7 (4 benign, 1 borderline, 2 malignant) Indian and 1 (malignant) Indonesian. Prevalence of benign versus combined borderline and malignant phyllodes showed a marginally significant difference (p=0.049) between the Malays and Chinese. Patients' ages ranged from 21-70 years with a mean of 44.9 years with no significant difference in age between benign, borderline or malignant phyllodes tumours. Except for benign phyllodes tumours (mean size = 5.8 cm) being significantly smaller at presentation compared with borderline (mean size = 12.5 cm) and malignant (mean size = 15.8 cm) (p<0.05) tumours, history of previous pregnancy, breast feeding, hormonal contraception and tumour laterality did not differ between the three categories. Family history of breast cancer was noted in 2 cases of benign phyllodes. Local excision was performed in 17 benign, 2 borderline and 3 malignant tumours and mastectomy in 4 benign, 2 borderline and 2 malignant tumours. Surgical clearance was not properly recorded in 10 benign phyllodes tumours. Six benign and all 4 borderline and 5 malignant tumours had clearances of <10 mm. Two benign tumours recurred locally at 15 and 49 months after local excision, however information regarding surgical clearance was not available in both cases. One patient with a malignant tumour developed a radiologically-diagnosed lung nodule 26 months after mastectomy, was given a course of radiotherapy and remained well 8-months following identification of the lung nodule.
Kusters, R W J; Simons, A P; Lancé, M D; Ganushchak, Y M; Bekers, O; Weerwind, P W
2017-01-01
Low-flow extracorporeal life support can be used for cardiopulmonary support of paediatric and neonatal patients and is also emerging as a therapy for patients suffering from exacerbation of chronic obstructive pulmonary disease. However, pump heating and haemolysis have proven to negatively affect the system and outcome. This in vitro study aimed at gaining insight into blood warming, pump heating and haemolysis related to the performance of a new low-flow centrifugal pump. Pump performance in the 400-1,500 ml/min flow range was modulated using small-sized dual-lumen catheters and freshly donated human blood. Measurements included plasma free haemoglobin, blood temperature, pump speed, pump pressure, blood flow and thermographic imaging. Blood warming (ΔT max =0.5°C) had no relationship with pump performance or haemolysis (R 2 max =0.05). Pump performance-related parameters revealed no relevant relationships with haemolysis (R 2 max =0.36). Thermography showed no relevant heat zones in the pump (T max =36°C). Concerning blood warming, pump heating and haemolysis, we deem the centrifugal pump applicable for low-flow extracorporeal circulation.
Grocott, Hilary P; Mathew, Joseph P; Carver, Elizabeth H; Phillips-Bute, Barbara; Landolfo, Kevin P; Newman, Mark F
2004-02-01
In this trial we compared the hypothermia avoidance abilities of the Arctic Sun Temperature Management System (a servo-regulated system that circulates temperature-controlled water through unique energy transfer pads adherent to the patient's body) with conventional temperature control methods. Patients undergoing off-pump coronary artery bypass (OPCAB) surgery were randomized to either the Arctic Sun System alone (AS group) or conventional methods (control group; increased room temperature, heated IV fluids, convective forced air warming system) for the prevention of hypothermia (defined by a temperature <36 degrees C). The AS group had nasopharyngeal temperature servo-regulated to a target of 36.8 degrees C. Temperature was recorded throughout the operative period and comparisons were made between groups for both the time and area under the curve (AUC) for a temperature <36 degrees C (AUC<36 degrees C). Twenty-nine patients (AS group = 14, control group = 15) were studied. The AS group had significantly less hypothermia than the control group, both for duration of time <36 degrees C (2.5 [0-22] min, median [interquartile range] AS group versus 118 [49-192] min, control group; P = 0.0008) as well as for AUC<36 degrees C (0.3 [0-2.2] degrees C x min, AS group versus 17.1 [3.6-173.4] degrees C x min, control group; P = 0.002). The Arctic Sun Temperature Management System significantly reduced intraoperative hypothermia during OPCAB surgery. Importantly, this was achieved in the absence of any other temperature modulating techniques, including the use of IV fluid warming or increases in the ambient operating room temperature. The Arctic Sun Temperature Management System was more effective than conventional methods in preventing hypothermia during off-pump coronary artery bypass graft surgery.
NASA Astrophysics Data System (ADS)
Shim, B.
2005-12-01
Aquifer thermal energy storage (ATES) can be a cost-effective and renewable energy source, depending on site-specific thermohydraulic conditions. To design an effective ATES system, the understanding of thermohydraulic processes is necessary. The heat transfer phenomena of an aquifer heat storage system are simulated with the scenario of heat pump operation of pumping and waste water reinjection in a two layered confined aquifer model having the effect of groundwater movement. Temperature distribution of the aquifer model is generated, and hydraulic heads and temperature variations are monitored at both wells during simulation days. The average groundwater velocities are determined with two assumed hydraulic gradients set by boundary conditions, and the effect of groundwater flow are shown at the generated thermal distributions at three different depth slices. The generated temperature contour lines at the hydraulic gradient of 0.001 are shaped circular, and the center is moved less than 5 m to the east in 365 days. However at the hydraulic gradient of 0.01, the contour centers of the east well at each depth slice are moved near the east boundary and the movement of temperature distribution is increased at the lower aquifer. By the analysis of thermal interference data between two wells the efficiency of a heat pump operation model is validated, and the variation of heads is monitored at injection, pumping and stabilized state. The thermal efficiency of the ATES system model is represented as highly depended on groundwater flow velocity and direction. Therefore the hydrogeologic condition for the system site should be carefully surveyed.
Chemical heat pump and chemical energy storage system
Clark, Edward C.; Huxtable, Douglas D.
1985-08-06
A chemical heat pump and storage system employs sulfuric acid and water. In one form, the system includes a generator and condenser, an evaporator and absorber, aqueous acid solution storage and water storage. During a charging cycle, heat is provided to the generator from a heat source to concentrate the acid solution while heat is removed from the condenser to condense the water vapor produced in the generator. Water is then stored in the storage tank. Heat is thus stored in the form of chemical energy in the concentrated acid. The heat removed from the water vapor can be supplied to a heat load of proper temperature or can be rejected. During a discharge cycle, water in the evaporator is supplied with heat to generate water vapor, which is transmitted to the absorber where it is condensed and absorbed into the concentrated acid. Both heats of dilution and condensation of water are removed from the thus diluted acid. During the discharge cycle the system functions as a heat pump in which heat is added to the system at a low temperature and removed from the system at a high temperature. The diluted acid is stored in an acid storage tank or is routed directly to the generator for reconcentration. The generator, condenser, evaporator, and absorber all are operated under pressure conditions specified by the desired temperature levels for a given application. The storage tanks, however, can be maintained at or near ambient pressure conditions. In another form, the heat pump system is employed to provide usable heat from waste process heat by upgrading the temperature of the waste heat.
Pump for molten metal or other fluid
Horton, James A.; Brown, Donald L.
1994-01-01
A pump having no moving parts which can be used to pump high temperature molten metal or other fluids in a vacuum or low pressure environment, and a method for pumping such fluids. The pump combines elements of a bubble pump with a trap which isolates the vacuum or low pressure region from the gas used to create the bubbles. When used in a vacuum the trap prevents the pumping gas from escaping into the isolated region and thereby reducing the quality of the vacuum. The pump includes a channel in which a pumping gas is forced under pressure into a cavity where bubbles are formed. The cavity is in contact with a reservoir which contains the molten metal or other fluid which is to be pumped. The bubbles rise up into a column (or pump tube) carrying the fluid with them. At the top of the column is located a deflector which causes the bubbles to burst and the drops of pumped fluid to fall into a trap. The fluid accumulates in the trap, eventually forcing its way to an outlet. A roughing pump can be used to withdraw the pumping gas from the top of the column and assist with maintaining the vacuum or low pressure environment.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-01-01
Major accomplishments during the second quarter of 1984 were completion of the Diaphragm Separation Seal clear liquid testing, and initiation of Phase III Field Testing. Diaphragm operational testing was conducted on a clear water test loop. The test goals were to ensure; mechanical reliability of the Diaphragm Seal, safe operation with simulated component failure, and proper operation of the Diaphragm Buffer Volume Control System. This latter system is essential in controlling the phasing of the diaphragm with its driving plunger. These tests were completed successfully. All operational problems were solved. However, it must be emphasized that the Diaphragm Seal wouldmore » be damaged by allowing the pump to operate in a cavitating condition for an extended period of time. A change in the Field Test phase of the program was made regarding choice of field test site. There is no operating Syn-Fuel pilot plant capable of inexpensively producing the slurry stream required for the reciprocating pump testing. The Field Tests will now be conducted by first testing the prototype pump and separation seals in an ambient temperature sand water slurry. This will determine resistence to abrasive wear and determine any operation problems at pressure over a lengthy period of time. After successful conclusion of these tests the pump and seals will be operated with a high temperature oil, but without solids, to identify any problems associated with thermal gradients, thermal shock and differential growth. After successful completion of the high temperature clean oil tests the pump will be deemed ready for in-line installation at a designated Syn-Fuel pilot plant. The above approach avoids the expense and complications of a separate hot slurry test loop. It also reduces risk of operational problems while in-line at the pilot plant. 5 figs.« less
Nakashima, Keisuke; Nakamura, Takumi; Takeuchi, Satoshi; Shibata, Mikihiro; Demura, Makoto; Tahara, Tahei; Kandori, Hideki
2009-06-18
Halorhodopsin (HR) is a light-driven chloride pump. Cl(-) is bound in the Schiff base region of the retinal chromophore, and unidirectional Cl(-) transport is probably enforced by the specific hydrogen-bonding interaction with the protonated Schiff base and internal water molecules. It is known that HR from Natronobacterium pharaonis (pHR) also pumps NO(3)(-) with similar efficiency, suggesting that NO(3)(-) binds to the Cl(-)-binding site. In the present study, we investigated the properties of the anion-binding site by means of ultrafast pump-probe spectroscopy and low-temperature FTIR spectroscopy. The obtained data were surprisingly similar between pHR-NO(3)(-) and pHR-Cl(-), even though the shapes and sizes of the two anions are quite different. Femtosecond pump-probe spectroscopy showed very similar excited-state dynamics between pHR-NO(3)(-) and pHR-Cl(-). Low-temperature FTIR spectroscopy of unlabeled and [zeta-(15)N]Lys-labeled pHR revealed almost identical hydrogen-bonding strengths of the protonated retinal Schiff base between pHR-NO(3)(-) and pHR-Cl(-), which is similarly strengthened after retinal isomerization. There were spectral variations for water stretching vibrations between pHR-NO(3)(-) and pHR-Cl(-), suggesting that the water molecules hydrate each anion. Nevertheless, the overall spectral features were similar for the two species. These observations strongly suggest that the anion-binding site has a flexible structure and that the interaction between retinal and the anions is weak, despite the presence of an electrostatic interaction. Such a flexible hydrogen-bonding network in the Schiff base region in HR appears to be in remarkable contrast to that in light-driven proton-pumping proteins.
2009-07-01
power supply, a temperature controller and a vacuum controller. A vacuum of < 1 )1 torr is achieved with a combination of a turbo pump and a... scroll pump system. The sanlple probing is accomplished with a 3-axis molybdenum probing rod test fixture .. The dielectric measurements on the...water. The films were dried at ~ 0.1 torr vacuum and 80-85°C in an oven for several days. Circular films varying in diameter from 2" to 4" were
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demidov, V. E.; Dzyapko, O.; Demokritov, S. O.
The room-temperature dynamics of a magnon gas driven by short microwave pumping pulses is studied. An overpopulation of the lowest energy level of the system following the pumping is observed. Using the sensitivity of the Brillouin light scattering technique to the coherence degree of the scattering magnons we demonstrate the spontaneous emergence of coherence of the magnons at the lowest level, if their density exceeds a critical value. This finding is clear proof of the quantum nature of the observed phenomenon and direct evidence of Bose-Einstein condensation of magnons at room temperature.
Côrtes, Marina Carvalho Souza; Rosario, Pedro Weslley; Oliveira, Luís Fernando Faria; Calsolari, Maria Regina
2018-02-01
Interference of antithyroglobulin antibodies (TgAb) with serum thyroglobulin (Tg) can occur even at detectable TgAb concentrations below the reference limit (borderline TgAb). Thus, borderline TgAb is considered as TgAb positivity in patients with thyroid cancer. This prospective study evaluated patients with papillary thyroid carcinoma with undetectable Tg and normal neck ultrasonography (US) after total thyroidectomy and ablation with 131 I, and compared tumor persistence/recurrence and long-term Tg and TgAb behavior in those with borderline versus undetectable TgAb. A total of 576 patients were evaluated, divided into two groups: group A with undetectable TgAb (n = 420), and group B with borderline TgAb (n = 156). Groups A and B were similar in terms of patient and tumor characteristics. The time of follow-up ranged from 24 to 120 months. During follow-up, 11 (2.6%) patients in group A and 5 (3.2%) in group B developed a recurrence (p = 0.77). In group A, recurrences occurred in 9/390 patients who continued to have undetectable TgAb and in 1/9 patients who progressed to borderline TgAb. In group B, recurrences were detected in 1/84 patients who progressed to have undetectable TgAb, in 1/45 who still had borderline TgAb, and in 3/12 who developed elevated TgAb. In the presence of Tg levels <0.2 ng/mL, recurrences were detected in 2/486 patients with undetectable TgAb, in 0/67 with borderline TgAb, and in 3/12 with elevated TgAb. The results of post-therapy whole-body scanning (RxWBS) of 216 patients with Tg ≤0.2 ng/mL and normal US at the time of ablation were also analyzed. In low-risk patients, none of the 40 patients with borderline TgAb and none of the 94 with undetectable TgAb exhibited ectopic uptake on RxWBS. In intermediate-risk patients, lymph node metastases were detected by RxWBS in 1/25 (4%) with borderline TgAb and in 2/57 (3.5%) with undetectable TgAb. The results suggest that among low- or intermediate-risk patients with undetectable Tg and normal US after thyroidectomy, those with borderline TgAb are at no greater risk of tumor persistence or recurrence than those with undetectable TgAb. When undetectable Tg levels persist, recurrence should be suspected in the case of a TgAb elevation above the reference limit.
Intelligent pump test system based on virtual instrument
NASA Astrophysics Data System (ADS)
Ma, Jungong; Wang, Shifu; Wang, Zhanlin
2003-09-01
The intelligent pump system is the key component of the aircraft hydraulic system that can solve the problem, such as the temperature sharply increasing. As the performance of the intelligent pump directly determines that of the aircraft hydraulic system and seriously affects fly security and reliability. So it is important to test all kinds of performance parameters of intelligent pump during design and development, while the advanced, reliable and complete test equipments are the necessary instruments for achieving the goal. In this paper, the application of virtual instrument and computer network technology in aircraft intelligent pump test is presented. The composition of the hardware, software, hydraulic circuit in this system are designed and implemented.
Carbon ion pump for removal of carbon dioxide from combustion gas and other gas mixtures
Aines, Roger D.; Bourcier, William L.
2014-08-19
A novel method and system of separating carbon dioxide from flue gas is introduced. Instead of relying on large temperature or pressure changes to remove carbon dioxide from a solvent used to absorb it from flue gas, the ion pump method, as disclosed herein, dramatically increases the concentration of dissolved carbonate ion in solution. This increases the overlying vapor pressure of carbon dioxide gas, permitting carbon dioxide to be removed from the downstream side of the ion pump as a pure gas. The ion pumping may be obtained from reverse osmosis, electrodialysis, thermal desalination methods, or an ion pump system having an oscillating flow in synchronization with an induced electric field.
Carbon ion pump for removal of carbon dioxide from combustion gas and other gas mixtures
Aines, Roger D.; Bourcier, William L.
2010-11-09
A novel method and system of separating carbon dioxide from flue gas is introduced. Instead of relying on large temperature or pressure changes to remove carbon dioxide from a solvent used to absorb it from flue gas, the ion pump method, as disclosed herein, dramatically increases the concentration of dissolved carbonate ion in solution. This increases the overlying vapor pressure of carbon dioxide gas, permitting carbon dioxide to be removed from the downstream side of the ion pump as a pure gas. The ion pumping may be obtained from reverse osmosis, electrodialysis, thermal desalination methods, or an ion pump system having an oscillating flow in synchronization with an induced electric field.
160mJ and 9ns electro-optics Q-switched conductively cooled 1047nm Nd:YLF laser
NASA Astrophysics Data System (ADS)
Yang, Qi; Ma, Jian; Lu, Tingting; Ma, Xiuhua; Zhu, Xiaolei
2015-02-01
A compact diode side-pumped conductively cooled 1047 nm Nd:YLF slab laser with high energy and short pulse width is developed. Through ray tracing method, we design a home-made pump module to homogenize the pump intensity. Based on the Possion equation, a thermal conduct model of side-pump laser is established. The temperature distribution in laser crystal is obtained, and the thermal lens is caculated. With the absorbed pump energy of 818 mJ, the maximum output energy of 228 mJ is achieved in free-running mode. At a repetition rate of 50 Hz, 160 mJ, 9 ns 1047 nm infrared light is obtained under the maximum absorbed pump energy, and the slope efficiency is 27.8%.
High Efficiency, High Performance Clothes Dryer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peter Pescatore; Phil Carbone
This program covered the development of two separate products; an electric heat pump clothes dryer and a modulating gas dryer. These development efforts were independent of one another and are presented in this report in two separate volumes. Volume 1 details the Heat Pump Dryer Development while Volume 2 details the Modulating Gas Dryer Development. In both product development efforts, the intent was to develop high efficiency, high performance designs that would be attractive to US consumers. Working with Whirlpool Corporation as our commercial partner, TIAX applied this approach of satisfying consumer needs throughout the Product Development Process for bothmore » dryer designs. Heat pump clothes dryers have been in existence for years, especially in Europe, but have not been able to penetrate the market. This has been especially true in the US market where no volume production heat pump dryers are available. The issue has typically been around two key areas: cost and performance. Cost is a given in that a heat pump clothes dryer has numerous additional components associated with it. While heat pump dryers have been able to achieve significant energy savings compared to standard electric resistance dryers (over 50% in some cases), designs to date have been hampered by excessively long dry times, a major market driver in the US. The development work done on the heat pump dryer over the course of this program led to a demonstration dryer that delivered the following performance characteristics: (1) 40-50% energy savings on large loads with 35 F lower fabric temperatures and similar dry times; (2) 10-30 F reduction in fabric temperature for delicate loads with up to 50% energy savings and 30-40% time savings; (3) Improved fabric temperature uniformity; and (4) Robust performance across a range of vent restrictions. For the gas dryer development, the concept developed was one of modulating the gas flow to the dryer throughout the dry cycle. Through heat modulation in a gas dryer, significant time and energy savings, combined with dramatically reduced fabric temperatures, was achieved in a cost-effective manner. The key design factor lay in developing a system that matches the heat input to the dryer with the fabrics ability to absorb it. The development work done on the modulating gas dryer over the course of this program led to a demonstration dryer that delivered the following performance characteristics: (1) Up to 25% reduction in energy consumption for small and medium loads; (2) Up to 35% time savings for large loads with 10-15% energy reduction and no adverse effect on cloth temperatures; (3) Reduced fabric temperatures, dry times and 18% energy reduction for delicate loads; and, (4) Robust performance across a range of vent restrictions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pitts, D.R.
1980-09-30
A conceptual design study for district heating of a 30-home subdivision located near the southeast extremity of the city of Elko, Nevada is presented. While a specific residential community was used in the study, the overall approach and methodologies are believed to be generally applicable for a large number of communities where low temperature geothermal fluid is available. The proposed district heating system utilizes moderate temperature, clean domestic water and existing community culinary water supply lines. The culinary water supply is heated by a moderate temperature geothermal source using a single heat exchanger at entry to the subdivision. The heatedmore » culinary water is then pumped to the houses in the community where energy is extracted by means of a water supplied heat pump. The use of heat pumps at the individual houses allows economic heating to result from supply of relatively cool water to the community, and this precludes the necessity of supplying objectionably hot water for normal household consumption use. Each heat pump unit is isolated from the consumptive water flow such that contamination of the water supply is avoided. The community water delivery system is modified to allow recirculation within the community, and very little rework of existing water lines is required. The entire system coefficient of performance (COP) for a typical year of heating is 3.36, exclusive of well pumping energy.« less
Exploding conducting film laser pumping apparatus
Ware, K.D.; Jones, C.R.
1984-04-27
The 342-nm molecular iodine and the 1.315-..mu..m atomic iodine lasers have been optically pumped by intense light from exploding-metal-film discharges. Brightness temperatures for the exploding-film discharges were approximately 25,000 K. Although lower output energies were achieved for such discharges when compared to exploding-wire techniques, the larger surface area and smaller inductance inherent in the exploding-film should lead to improved efficiency for optically-pumped gas lasers.
CW molecular iodine laser pumped with a low power DPSSL
NASA Astrophysics Data System (ADS)
Luhs, W.; Wellegehausen, B.; Goyal, M.
2017-04-01
Cw oscillation of molecular iodine on many lines in the range of 557-802 nm pumped with a low power common diode pumped and frequency doubled solid state laser DPSSL is reported. The DPSSL is temperature stabilized, operates in single frequency and can be tuned by about 2 nm at 532 nm. Operation conditions of this simple and low cost iodine ring laser will be described and possible applications will be discussed.
NASA Astrophysics Data System (ADS)
Afalla, Jessica; Ohta, Kaoru; Tokonami, Shunrou; Prieto, Elizabeth Ann; Catindig, Gerald Angelo; Cedric Gonzales, Karl; Jaculbia, Rafael; Vasquez, John Daniel; Somintac, Armando; Salvador, Arnel; Estacio, Elmer; Tani, Masahiko; Tominaga, Keisuke
2017-11-01
Two asymmetric double quantum wells of different coupling strengths (barrier widths) were grown via molecular beam epitaxy, both samples allowing tunneling. Photoluminescence was measured at 10 and 300 K to provide evidence of tunneling, barrier dependence, and structural uniformity. Carrier dynamics at room temperature was investigated by optical pump terahertz probe (OPTP) spectroscopy. Carrier population decay rates were obtained and photoconductivity spectra were analyzed using the Drude model. This work demonstrates that carrier, and possibly tunneling dynamics in asymmetric double quantum well structures may be studied at room temperature through OPTP spectroscopy.
Fulford, Daniel; Eisner, Lori R; Johnson, Sheri L
2015-06-30
Researchers and clinicians have long noted the overlap among features and high comorbidity of bipolar disorder and borderline personality disorder. The shared features of impulsivity and labile mood in both disorders make them challenging to distinguish. We tested the hypothesis that variables related to goal dysregulation would be uniquely related to risk for mania, while emotion-relevant impulsivity would be related to risk for both disorders. We administered a broad range of measures related to goal regulation traits and impulsivity to 214 undergraduates. Findings confirmed that risk for mania, but not for borderline personality disorder, was related to higher sensitivity to reward and intense pursuit of goals. In contrast, borderline personality disorder symptoms related more strongly than did mania risk with threat sensitivity and with impulsivity in the context of negative affect. Results highlight potential differences and commonalities in mania risk versus borderline personality disorder risk. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Borderline Personality and Externalized Aggression
Sansone, Lori A.
2012-01-01
Individuals with borderline personality disorder are diagnostically and clinically characterized by self-harm behavior, as indicated by the criterion in the Diagnostic and Statistical Manual of Mental Disorders, 4th Edition, Text Revision, “recurrent suicidal behavior, gestures, or threats, or self-mutilating behavior.” However, individuals with borderline personality disorder can display externalized aggressive behavior, as well. In an area characterized by considerably less research, empirical evidence indicates that individuals with borderline personality disorder may exhibit physical violence toward partners, physical violence toward known but nonintimate individuals, criminal behaviors that embody externalized violence (e.g., property damage), and, on very rare occasion, murderous behavior (either of family members or anonymous others through serial killing). Given this under-researched area, there are probably other types of externalized aggressive behaviors that have not been empirically revealed. However, externalized aggressive behaviors in individuals with borderline personality disorder clearly exist and need to be assessed in both psychiatric and primary care settings in an effort to promote safety of medical personnel and effective patient management. PMID:22567607
Dickens, Geoffrey L; Frogley, Catherine; Mason, Fiona; Anagnostakis, Katina; Picchioni, Marco M
2016-01-01
Clozapine is an atypical antipsychotic medicine which can cause significant side-effects. It is often prescribed off-license in severe cases of borderline personality disorder contrary to national treatment guidelines. Little is known about the experiences of those who take clozapine for borderline personality disorder. We explored the lived-experience of women in secure inpatient care who were prescribed clozapine for borderline personality disorder. Adult females ( N = 20) participated in audio-taped semi-structured interviews. Transcripts were subject to thematic analysis. The central themes related to evaluation, wellbeing, understanding and self-management; for many, their subjective wellbeing on clozapine was preferred to prior levels of functioning and symptomatology, sometimes profoundly so. The negative and potentially adverse effects of clozapine were explained as regrettable but relatively unimportant. When psychological interventions are, at least initially, ineffective then clozapine treatment is likely to be evaluated positively by a group of women with borderline personality disorder in secure care despite the potential disadvantages.
Fossati, Andrea; Gratz, Kim L; Somma, Antonella; Maffei, Cesare; Borroni, Serena
2016-10-01
In order to evaluate if emotion dysregulation significantly mediates the relationships between childhood abuse and adult attachment and borderline personality disorder features, 354 community Italian adults were administered the Borderline Personality Inventory (Leichsenring, 1999a), the Difficulties in Emotion Regulation Scale (Gratz & Roemer, 2004), the Child Abuse and Trauma Scale (Sanders & Becker-Lausen, 1995), and the Attachment Style Questionnaire (Feeney, Noller, & Hanrahan, 1994). Hierarchical regression analyses showed that both childhood abuse and adult attachment were positively associated with emotion dysregulation and borderline personality features; however, only emotional abuse and the attachment dimension of need for approval were common predictors of both dependent variables. No significant interaction effects were detected in regression analyses. Mediation analyses provided support for partial mediation, revealing a significant mediating role of emotion dysregulation in the relationships between both emotional abuse and need for approval and borderline personality features in this community sample.
Impulsivity, Rejection Sensitivity, and Reactions to Stressors in Borderline Personality Disorder
Berenson, Kathy R.; Gregory, Wesley Ellen; Glaser, Erin; Romirowsky, Aliza; Rafaeli, Eshkol; Yang, Xiao; Downey, Geraldine
2016-01-01
This research investigated baseline impulsivity, rejection sensitivity, and reactions to stressors in individuals with borderline personality disorder compared to healthy individuals and those with avoidant personality disorder. The borderline group showed greater impulsivity than the avoidant and healthy groups both in a delay-discounting task with real monetary rewards and in self-reported reactions to stressors; moreover, these findings could not be explained by co-occurring substance use disorders. Distress reactions to stressors were equally elevated in both personality disorder groups (relative to the healthy group). The borderline and avoidant groups also reported more maladaptive reactions to a stressor of an interpersonal vs. non-interpersonal nature, whereas the healthy group did not. Finally, self-reported impulsive reactions to stressors were associated with baseline impulsivity in the delay-discounting task, and greater self-reported reactivity to interpersonal than non-interpersonal stressors was associated with rejection sensitivity. This research highlights distinct vulnerabilities contributing to impulsive behavior in borderline personality disorder. PMID:27616800
Dependence on Excitation Density of Multiphonon Decay in Er-doped ZBLAN Glass
NASA Astrophysics Data System (ADS)
Bycenski, Kenneth; Collins, John
2001-11-01
The dependence of multiphonon decay of rare earth ions in solids on the intensity of the pump beam, first reported by Auzel et al., is examined for the 4S3/2 and 2H11/2 levels of Er-doped ZBLAN glass. Using a frequency-doubled, Q-switched Nd:YAG laser as a pump source, the kinetics of the 4S3/2 level was studied at different pump intensities and temperatures. Lifetime curves show a rise time, which represents the feeding of the 4S3/2 level by the 2H11/2, and a decay time that vary with the intensity of the pump beam, i.e. on the concentration of excited centers. The measured decay times of the 4S3/2 are consistent with those previously reported [2]. In this poster we report on the temperature dependence of this process, and we look at the dependence of the feeding of the 4S3/2 level as pump intensity changes. A rate equation model shows that the intensity dependence of the rise time on pump intensity is due, in part, to a slowing down of the nonradiative decay from the 2H11/2 level as the pump intensity is increased. We discuss these results in terms of the phonon bottleneck mechanism proposed in reference 1. 1. F. Auzel and F. Pelle, Phys. Rev. B 55, 17 (1106-09) 1997. 2. F Auzel, private communications.
Compact, Lightweight Electromagnetic Pump for Liquid Metal
NASA Technical Reports Server (NTRS)
Godfroy, Thomas; Palzin, Kurt
2010-01-01
A proposed direct-current electromagnetic pump for circulating a molten alkali metal alloy would be smaller and lighter and would demand less input power, relative to currently available pumps of this type. (Molten alkali metals are used as heat-transfer fluids in high-temperature stages of some nuclear reactors.) The principle of operation of this or any such pump involves exploitation of the electrical conductivity of the molten metal: An electric current is made to pass through the liquid metal along an axis perpendicular to the longitudinal axis of the flow channel, and a magnetic field perpendicular to both the longitudinal axis and the electric current is superimposed on the flowchannel region containing the electric current. The interaction between the electric current and the magnetic field produces the pumping force along the longitudinal axis. The advantages of the proposed pump over other such pumps would accrue from design features that address overlapping thermal and magnetic issues.
Efficient Tm:Fiber Pumped Solid-State Ho:YLF 2-micrometer Laser for Remote Sensing Applications
NASA Technical Reports Server (NTRS)
Singh, Upendra N.; Bai, Yingxin; Yu, Jirong; Petros, Mulugeta
2012-01-01
An efficient 19 W, TEM(sub 00) mode, Ho:YLF laser pumped by continuous wave Tm:fiber laser has been demonstrated at the room temperature. The slope efficiency and optical-to-optical efficiency are 65% and 55%, respectively.
ERIC Educational Resources Information Center
Galus, Pamela
2002-01-01
Introduces a science demonstration that illustrates the effects of pressure and gravity on humans using a marshmallow man and a vacuum pump. Demonstrates the same concept with shaving cream, balloons, and boiling water without raising temperature. (YDS)
NASA Astrophysics Data System (ADS)
Ding, Mingjie; Luo, Yanhua; Wen, Jianxiang; Peng, Gang-Ding
2018-02-01
Ultra-wide emission in bismuth doped optical fiber has been extremely studied for the development of the laser and amplifier working at near infrared band. In our homemade bismuth/erbium co-doped optical fiber, bismuth active center associated with silica (BAC-Si) has been found that when pumping at its resonant wavelength at 830 nm the NIR emission could be partially bleached. In addition, a self-recovery process has been observed at room temperature. However, the exact mechanism is still unclear. In this work, we have investigated the photo-bleaching effect on the BAC-Si via the pump power, pump wavelength and temperature dependence. Based on analyzing the result using stretched exponential function, it shows that the bleaching effect on BAC-Si has a strong link with the excitation process of Bi ion in BAC-Si. A potential energy curve model is used to illustrate the BAC-Si photo-bleaching process.
Leak Mitigation in Mechanically Pumped Fluid Loops for Long Duration Space Missions
NASA Technical Reports Server (NTRS)
Miller, Jennifer R.; Birur, Gajanana; Bame, David; Mastropietro, A. J.; Bhandari, Pradeep; Lee, Darlene; Karlmann, Paul; Liu, Yuanming
2013-01-01
Mechanically pumped fluid loops (MPFLs) are increasingly considered for spacecraft thermal control. A concern for long duration space missions is the leak of fluid leading to performance degradation or potential loop failure. An understanding of leak rate through analysis, as well as destructive and non-destructive testing, provides a verifiable means to quantify leak rates. The system can be appropriately designed to maintain safe operating pressures and temperatures throughout the mission. Two MPFLs on the Mars Science Laboratory Spacecraft, launched November 26, 2011, maintain the temperature of sensitive electronics and science instruments within a -40 deg C to 50 deg C range during launch, cruise, and Mars surface operations. With over 100 meters of complex tubing, fittings, joints, flex lines, and pumps, the system must maintain a minimum pressure through all phases of the mission to provide appropriate performance. This paper describes the process of design, qualification, test, verification, and validation of the components and assemblies employed to minimize risks associated with excessive fluid leaks from pumped fluid loop systems.
ERIC Educational Resources Information Center
Bedics, Jamie D.; Atkins, David C.; Comtois, Katherine A.; Linehan, Marsha M.
2012-01-01
Objective: The present study explored the role of the therapeutic relationship and introject during the course of dialectical behavior therapy (DBT; Linehan, 1993) for the treatment of borderline personality disorder. Method: Women meeting "DSM-IV" criteria for borderline personality disorder (N = 101) were randomized to receive DBT or community…
Ghiasi, Hamed; Mohammadi, Abolalfazl; Zarrinfar, Pouria
2016-01-01
Objective: Borderline personality disorder is one of the most complex and prevalent personality disorders. Many variables have so far been studied in relation to this disorder. This study aimed to investigate the role of emotion regulation, attachment styles, and theory of mind in predicting the traits of borderline personality disorder. Method: In this study, 85 patients with borderline personality disorder were selected using convenience sampling method. To measure the desired variables, the questionnaires of Gross emotion regulation, Collins and Read attachment styles, and Baron Cohen's Reading Mind from Eyes Test were applied. The data were analyzed using multivariate stepwise regression technique. Results: Emotion regulation, attachment styles, and theory of mind predicted 41.2% of the variance criterion altogether; among which, the shares of emotion regulation, attachment styles and theory of mind to the distribution of the traits of borderline personality disorder were 27.5%, 9.8%, and 3.9%, respectively. Conclusion: The results of the study revealed that emotion regulation, attachment styles, and theory of mind are important variables in predicting the traits of borderline personality disorder and that these variables can be well applied for both the treatment and identification of this disorder. PMID:28050180
Zanarini, Mary C; Temes, Christina M; Ivey, Alexandra M; Cohn, Danielle M; Conkey, Lindsey C; Frankenburg, Frances R; Fitzmaurice, Garrett M
2017-06-01
This study had two aims. The first was to assess and compare various types of aggressive behavior toward others reported by borderline patients and axis II comparison subjects over time. The second was to determine the best baseline and time-varying predictors of aggressive behavior in these borderline patients. At baseline, a series of interviews and self-report measures were administered to 290 borderline patients and 72 axis II comparison subjects. Measures assessing aggression toward others, axis I and II disorders as well as adult adversity were re-administered every two years over the course of ten years. It was found that borderline patients reported significantly higher rates of verbal, emotional, and physical aggression toward others than comparison subjects but the rates of these forms of aggression toward others declined significantly for those in both study groups. Multivariate analyses indicated that the strongest predictors of adult aggression towards others were severity of adult adversity and a substance use disorder. Taken together, these results suggest that borderline patients commonly report aggression toward others but that this aggression declines significantly over time. These results also suggest that this aggression toward others is most strongly associated with adult experiences of adversity and concurrent substance abuse. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Koenig, Julian; Brunner, Romuald; Schmidt, Johannes Michael; Parzer, Peter; Resch, Franz; Kaess, Michael
2017-11-01
Self-injurious behavior (SIB) is a widespread phenomenon among adolescent psychiatric inpatients. It is also reported among delinquent adolescents detained in correctional facilities. While previous studies have addressed different functions of SIB within offender populations, here we investigate particular patterns of borderline personality pathology and psychopathology underlying SIB in both adolescent psychiatric inpatients and detainees. Adolescent psychiatric inpatients and detainees were recruited consecutively. Participants completed self-reports on SIB, suicidal thoughts and behavior, borderline personality pathology, and general psychopathology. Predictors of lifetime SIB by group were analyzed. Psychiatric inpatients (n = 77) and detainees (n = 50) did not differ with respect to lifetime SIB (57.14 % versus 54.00 %), whereas SIB within the past year did (67.53 % versus 14 %; χ2 (1) = 6.158, p = .013). Psychiatric inpatients reported greater emotional problems (t (125) = 5.109, p < .0001) and greater borderline personality pathology. Those with lifetime SIB were characterized by greater emotional problems and borderline personality pathology, independent of their group. Results from regression analyses suggest no group-specific predictors of lifetime SIB. Although psychiatric inpatients endorse greater psychopathological distress, lifetime SIB among adolescent psychiatric inpatients and detainees is associated with similar patterns of psychopathology and borderline personality pathology.
Lu, Wei-Hsin; Wang, Peng-Wei; Ko, Chih-Hung; Hsiao, Ray C; Liu, Tai-Ling; Yen, Cheng-Fang
2018-04-01
This study examined the differences in mental health and behavioral problems among young adults with borderline personality symptoms of various severities. 500 college students participated in this study. Borderline personality symptoms were evaluated using the Taiwanese version of the Borderline Symptom List (BSL-23). Mental health problems were assessed using the Symptom Checklist-90-Revised Scale. Suicidality and other behavioral problems were assessed using questions from the epidemiological version of the Kiddie Schedule for Affective Disorders and Schizophrenia and BSL-23 Supplement. According to the distribution of BSL-23 scores at the 25th, 50th, and 75th percentiles, the participants were divided into 4 groups: No/Mild, Moderate, Severe, and Profound. Analysis of variance and the chi-square test were used to compare mental health and behavioral problems among the 4 groups. All mental health problems differed significantly among the 4 groups. The severity of nearly all mental health problems increased with that of borderline personality symptoms. The proportions of most behavioral problems differed significantly among the 4 groups. The Profound group was more likely to have behavioral problems than the other 3 groups. Young adults who had more severe borderline personality symptoms had more severe mental health and behavioral problems. Copyright © 2017. Published by Elsevier B.V.
Mahan, Rebecca M; Kors, Stephanie B; Simmons, Meredith L; Macfie, Jenny
2017-12-14
Linehan (1993) theorized that the experience of invalidating parenting interacts with emotional vulnerability in the development of borderline personality disorder (BPD). Parental psychological control is a type of invalidating parenting, defined as manipulation by parents of their offspring's psychological and emotional expression and experience (Barber, 1996). In a normative sample of adolescent females, adolescent-reported maternal psychological control was related to maternal borderline symptoms (Zalewski et al., 2014). The current study expanded on these findings to sample mothers with a diagnosis of BPD (n = 28) and normative comparisons (n = 28) with male and female adolescents aged 14-18. We assessed maternal and adolescent self-reported borderline features (affective instability, negative relationships, identity disturbance, and self-harm) and coded maternal psychological control from filmed problem-solving interactions. Controlling for current major depressive disorder and family income, mothers with BPD used more total psychological control with their adolescents in comparison with normative mothers. Further, maternal psychological control was positively associated with all mothers' borderline features and with adolescent affective instability. Finally, we found a significant indirect effect for maternal affective instability between maternal total psychological control and adolescent affective instability. We discuss adolescents' risk of developing BPD themselves and prevention and treatment implications. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Ghiasi, Hamed; Mohammadi, Abolalfazl; Zarrinfar, Pouria
2016-10-01
Objective: Borderline personality disorder is one of the most complex and prevalent personality disorders. Many variables have so far been studied in relation to this disorder. This study aimed to investigate the role of emotion regulation, attachment styles, and theory of mind in predicting the traits of borderline personality disorder. Method: In this study, 85 patients with borderline personality disorder were selected using convenience sampling method. To measure the desired variables, the questionnaires of Gross emotion regulation, Collins and Read attachment styles, and Baron Cohen's Reading Mind from Eyes Test were applied. The data were analyzed using multivariate stepwise regression technique. Results: Emotion regulation, attachment styles, and theory of mind predicted 41.2% of the variance criterion altogether; among which, the shares of emotion regulation, attachment styles and theory of mind to the distribution of the traits of borderline personality disorder were 27.5%, 9.8%, and 3.9%, respectively. Conclusion : The results of the study revealed that emotion regulation, attachment styles, and theory of mind are important variables in predicting the traits of borderline personality disorder and that these variables can be well applied for both the treatment and identification of this disorder.
Reported childhood onset of self-mutilation among borderline patients.
Zanarini, Mary C; Frankenburg, Frances R; Ridolfi, Maria E; Jager-Hyman, Shari; Hennen, John; Gunderson, John G
2006-02-01
The purpose of this study was to determine the percentage of borderline patients who first engaged in self-mutilation as children and to compare the parameters of their self-harm to those of borderline patients who first harmed themselves at an older age. Two hundred and ninety inpatients meeting both Revised Diagnostic Interview for Borderlines (DIB-R; Zanarini, Gunderson, Frankenburg, & Chauncey, 1989) and Diagnostic and Statistical Manual of Mental Disorders (3rd ed. ref.) (DSM-III-R; APA, 1987) criteria for borderline personality disorder were interviewed about their history of self-mutilation. Of the 91% with a history of self mutilation, 32.8% reported first harming themselves as children (12 years of age or younger), 30.2% as adolescents (13-17 years of age), and 37% as adults (18 or older). Using logistic regression analyses and controlling for baseline age, it was found that those with a childhood onset reported more episodes of self-harm, a longer duration of self-harm, and a greater number of methods of self-harm than either those with an adolescent or adult onset to their self-mutilation. The results of this study suggest that a sizable minority of borderline patients first engage in self-harm as children and that the course of their self-mutilation may be particularly malignant.
Epithelial borderline ovarian tumor: Diagnosis and treatment strategy.
Ushijima, Kimio; Kawano, Kouichiro; Tsuda, Naotake; Nishio, Shin; Terada, Atsumu; Kato, Hiroyuki; Tasaki, Kazuto; Matsukuma, Ken
2015-05-01
Epithelial borderline ovarian tumors (BOT) are distinctive from benign tumors and carcinoma. They occur in younger women more often than carcinoma, and there is some difficulty making correct diagnosis of BOT. Two subtypes of BOT, serous and mucinous borderline tumor have different characteristics and very different clinical behavior. Serous borderline tumor (SBT) with micropapillary pattern shows more incidence of extra ovarian disease and often coexists with invasive implant. SBT with micropapillary pattern in advanced stage has showed a worse prognosis than typical SBT. Huge mucinous borderline tumors have histologic heterogeneity, and the accuracy of frozen section diagnosis is relatively low. Extensive sampling is required to reach a correct pathological diagnosis. Mucinous adenoma (intestinal type) also runs the risk of recurrence after cystectomy, or intraoperative rupture of cyst. Laparoscopic procedure for BOT has not increased the risk of recurrence. Fertility preserving procedures are generally accepted, except in advanced stage SBT with invasive implants. Only cystectomy shows a significant risk of recurrence. Re-staging surgery and full staging surgery is not necessary for all BOT. We should not attempt to treat them uniformly, by the single diagnosis of "borderline tumor". It depends on histologic type. Close communication with the pathologist is necessary to gain more detail and ask more pathological samples in order to make the optimal treatment strategy for each individual patients.
Swann, Alan C; Lijffijt, Marijn; Lane, Scott D; Steinberg, Joel L; Moeller, F Gerard
2013-06-01
Interactions between characteristics of bipolar and Axis II cluster B disorders are clinically and diagnostically challenging. Characteristics associated with personality disorders may be dimensional aspects of bipolar disorder. We investigated relationships among antisocial personality disorder (ASPD) or borderline personality disorder symptoms, impulsivity, and course of illness in bipolar disorder. Subjects with bipolar disorder were recruited from the community. Diagnosis was by structured clinical interview for DSM-IV (SCID-I and -II), psychiatric symptom assessment by the change version of the schedule for affective disorders and schizophrenia (SADS-C), severity of Axis II symptoms by ASPD and borderline personality disorder SCID-II symptoms, and impulsivity by the Barratt impulsiveness scale (BIS-11). ASPD and borderline symptoms were not related to clinical state or affective symptoms. Borderline symptoms correlated with BIS-11 impulsivity scores, and predicted history of suicide attempts independently of the relationship to impulsivity. ASPD symptoms were more strongly related to course of illness, including early onset, frequent episodes, and substance-related disorders. These effects persisted after allowance for gender and substance-use disorder history. Personality disorder symptoms appear to be dimensional, trait-like characteristics of bipolar disorder. ASPD and Borderline symptoms are differentially related to impulsivity and course of illness. Copyright © 2012 Elsevier B.V. All rights reserved.
Swann, Alan C.; Lijffijt, Marijn; Lane, Scott D.; Steinberg, Joel L.; Moeller, F. Gerard
2012-01-01
Background Interactions between characteristics of bipolar and Axis II cluster B disorders are clinically and diagnostically challenging. Characteristics associated with personality disorders may be dimensional aspects of bipolar disorder. We investigated relationships among antisocial personality disorder (ASPD) or borderline personality disorder symptoms, impulsivity, and course of illness in bipolar disorder. Methods Subjects with bipolar disorder were recruited from the community. Diagnosis was by Structured Clinical Interview for DSM-IV (SCID-I and –II), psychiatric symptom assessment by the Change version of the Schedule for Affective Disorders and Schizophrenia (SADS-C), severity of axis II symptoms by ASPD and borderline personality disorder SCID-II symptoms, and impulsivity by the Barratt Impulsiveness Scale (BIS-11). Results ASPD and borderline symptoms were not related to clinical state or affective symptoms. Borderline symptoms correlated with BIS-11 impulsivity scores, and predicted history of suicide attempts independently of the relationship to impulsivity. ASPD symptoms were more strongly related to course of illness, including early onset, frequent episodes, and substance-related disorders. These effects persisted after allowance for gender and substance-use disorder history. Conclusions Personality disorder symptoms appear to be dimensional, trait-like characteristics of bipolar disorder. ASPD and Borderline symptoms are differentially related to impulsivity and course of illness. PMID:22835849
Custom Unit Pump Design and Testing for the EVA PLSS
NASA Technical Reports Server (NTRS)
Schuller, Michael; Kurwitz, Cable; Goldman, Jeff; Morris, Kim; Trevino, Luis
2009-01-01
This paper describes the effort by the Texas Engineering Experiment Station (TEES) and Honeywell for NASA to design and test a pre-flight prototype pump for use in the Extra-vehicular activity (EVA) portable life support subsystem (PLSS). Major design decisions were driven by the need to reduce the pump s mass, power, and volume compared to the existing PLSS pump. In addition, the pump must accommodate a much wider range of abnormal conditions than the existing pump, including vapor/gas bubbles and increased pressure drop when employed to cool two suits simultaneously. A positive displacement, external gear type pump was selected because it offers the most compact and highest efficiency solution over the required range of flow rates and pressure drops. An additional benefit of selecting a gear pump design is that it is self priming and capable of ingesting non-condensable gas without becoming air locked. The chosen pump design consists of a 28 V DC, brushless, sealless, permanent magnet motor driven, external gear pump that utilizes a Honeywell development that eliminates the need for magnetic coupling. Although the planned flight unit will use a sensorless motor with custom designed controller, the pre-flight prototype to be provided for this project incorporates Hall effect sensors, allowing an interface with a readily available commercial motor controller. This design approach reduced the cost of this project and gives NASA more flexibility in future PLSS laboratory testing. The pump design was based on existing Honeywell designs, but incorporated features specifically for the PLSS application, including all of the key features of the flight pump. Testing at TEES verified that the pump meets the design requirements for range of flow rates, pressure drop, power consumption, working fluid temperature, operating time, gas ingestion , and restart capability under both ambient and vacuum conditions. The pump operated between 40 and 240 lbm/hr flowrate, 35 to 100 F pump temperature range, and 5 to 10 psid pressure rise. Power consumption of the pump controller at the nominal operating point in both ambient and vacuum conditions was 9.5 W, which was less than the 12 W predicted. Gas ingestion capabilities were tested by injecting 100 cc of air into the fluid line; the pump operated normally throughout this test. The test results contained a number of anomalies, specifically power increases and a few flow stoppages, that prompted TEES and Honeywell to disassemble and inspect the pump. Inspection indicated contamination in the pump and fit issues may have played roles in the observed anomalies. Testing following reassembly indicated that the performance of the pump 1) matched both the predicted performance values, 2) the performance values measured prior to disassembly, and 3) was free of the anomalies noted in the pre-disassembly testing.
Tune, Sarah; Schlesewsky, Matthias; Small, Steven L.; Sanford, Anthony J.; Bohan, Jason; Sassenhagen, Jona; Bornkessel-Schlesewsky, Ina
2014-01-01
The N400 event-related brain potential (ERP) has played a major role in the examination of how the human brain processes meaning. For current theories of the N400, classes of semantic inconsistencies which do not elicit N400 effects have proven particularly influential. Semantic anomalies that are difficult to detect are a case in point (“borderline anomalies”, e.g. “After an air crash, where should the survivors be buried?”), engendering a late positive ERP response but no N400 effect in English (Sanford, Leuthold, Bohan, & Sanford, 2011). In three auditory ERP experiments, we demonstrate that this result is subject to cross-linguistic variation. In a German version of Sanford and colleagues' experiment (Experiment 1), detected borderline anomalies elicited both N400 and late positivity effects compared to control stimuli or to missed borderline anomalies. Classic easy-to-detect semantic (non-borderline) anomalies showed the same pattern as in English (N400 plus late positivity). The cross-linguistic difference in the response to borderline anomalies was replicated in two additional studies with a slightly modified task (Experiment 2a: German; Experiment 2b: English), with a reliable LANGUAGE × ANOMALY interaction for the borderline anomalies confirming that the N400 effect is subject to systematic cross-linguistic variation. We argue that this variation results from differences in the language-specific default weighting of top-down and bottom-up information, concluding that N400 amplitude reflects the interaction between the two information sources in the form-to-meaning mapping. PMID:24447768
Cicchetti, Dante; Rogosch, Fred A.; Hecht, Kathryn F.; Crick, Nicki R; Hetzel, Susan
2014-01-01
In this investigation, gene-environment-gender interaction effects in predicting child borderline personality disorder symptomatology among maltreated and nonmaltreated low-income children (N = 1,051) were examined. In the context of a summer research camp, adult-peer-, and self-report assessments of borderline precursor indicators were obtained, as well as child self-report on the Borderline Personality Features Scale-Children. Genetic variants of the OXTR genotype and the FKPB5 CATT haplotype were investigated. Children who self-reported high levels of borderline personality symptomatology were differentiated by adults, peers, and additional self-report on indicators of emotional instability, conflictual relationships with peers and adults, preoccupied attachment, and indicators of self-harm and suicidal ideation. Maltreated children also were more likely to evince many of these difficulties relative to nonmaltreated children. In a series of ANCOVAs, controlling for age and ancestrally informative markers, indicated significant maltreatment X gene X gender three-way interactions. Consideration of the maltreatment parameters of subtype, onset, and recency expanded understanding of variation among maltreated children. The three-way interaction effects demonstrated differential patterns among girls and boys. Among girls, the gene-environment interaction was more consistent with a diathesis-stress model, whereas among boys a differential-sensitivity interaction effect was indicated. Moreover, the genetic variants associated with greater risk for higher borderline symptomatology, dependent on maltreatment experiences, were opposite in girls compared to boys. The findings have important implications for understanding variability in early predictors of borderline personality pathology. PMID:25047302
Unblending Borderline Personality and Bipolar Disorders.
di Giacomo, Ester; Aspesi, Flora; Fotiadou, Maria; Arntz, Arnoud; Aguglia, Eugenio; Barone, Lavinia; Bellino, Silvio; Carpiniello, Bernardo; Colmegna, Fabrizia; Lazzari, Marina; Lorettu, Liliana; Pinna, Federica; Sicaro, Aldo; Signorelli, Maria Salvina; Clerici, Massimo
2017-08-01
Borderline Personality (BPD) and Bipolar (BP) disorders stimulate an academic debate between their distinction and the inclusion of Borderline in the Bipolar spectrum. Opponents to this inclusion attribute the important differences and possible diagnostic incomprehension to overlapping symptoms. We tested 248 Borderline and 113 Bipolar patients, consecutively admitted to the Psychiatric Unit, through DSM-IV Axis I and II Disorders (SCID-I/II), Hamilton Depression Rating Scale (HAM-D), Hamilton Anxiety Rating Scale (HAM-A), Young Mania Rating Scale (YMRS) and Borderline Personality Disorder Severity Index-IV (BPDSI-IV). All the tests statistically discriminated the disorders (p < 0.0001). Overlapping symptoms resulted significantly different (impulsivity = 5.32 in BPD vs 1.55 in BP, p < 0.0001; emotional instability = 7.11 in BPD vs 0.55 in BP, p < 0.0001) and the range of their scores gives the opportunity for an even more precise discrimination. Distinctive traits (e.g. irritability or sexual arousal) are also discussed in order to try to qualify the core of these disorders to a higher degree. Comorbidity proves to be extremely small (3.6%). However, Borderline patients with manic features offer a privileged point of view for a deeper analysis. This allows for the possibility of a more precise examination of the nature and load of each symptom. Borderline Personality and Bipolar Disorders can be distinguished with high precision using common and time-sparing tests. The importance of discriminating these clinical features may benefit from this evidence. Copyright © 2017. Published by Elsevier Ltd.
Cicchetti, Dante; Rogosch, Fred A; Hecht, Kathryn F; Crick, Nicki R; Hetzel, Susan
2014-08-01
In this investigation, gene-environment-gender interaction effects in predicting child borderline personality disorder symptomatology among maltreated and nonmaltreated low-income children (N = 1,051) were examined. In the context of a summer research camp, adult-, peer-, and self-report assessments of borderline precursor indicators were obtained, as well as child self-report on the Borderline Personality Features Scale for Children. Genetic variants of the oxytocin receptor genotype and the FK506 binding protein 5 gene CATT haplotype were investigated. Children who self-reported high levels of borderline personality symptomatology were differentiated by adults, peers, and additional self-report on indicators of emotional instability, conflictual relationships with peers and adults, preoccupied attachment, and indicators of self-harm and suicidal ideation. Maltreated children also were more likely to evince many of these difficulties relative to nonmaltreated children. A series of analyses of covariance, controlling for age and ancestrally informative markers, indicated significant Maltreatment × Gene × Gender three-way interactions. Consideration of the maltreatment parameters of subtype, onset, and recency expanded understanding of variation among maltreated children. The three-way interaction effects demonstrated differential patterns among girls and boys. Among girls, the gene-environment interaction was more consistent with a diathesis-stress model, whereas among boys a differential-sensitivity interaction effect was indicated. Moreover, the genetic variants associated with greater risk for higher borderline symptomatology, dependent on maltreatment experiences, were opposite in girls compared to boys. The findings have important implications for understanding variability in early predictors of borderline personality pathology.
Immigrants and borderline personality disorder at a psychiatric emergency service.
Pascual, J C; Malagón, A; Córcoles, D; Ginés, J M; Soler, J; García-Ribera, C; Pérez, V; Bulbena, A
2008-12-01
Several studies have suggested that immigrants have higher rates of psychiatric emergency service use and a higher risk of mental disorders such as schizophrenia than indigenous populations. To compare the likelihood that immigrants (immigrant group) v. indigenous population (indigenous group) will be diagnosed with borderline personality disorder in a psychiatric emergency service and to determine differences according to area of origin. A total of 11 578 consecutive admissions over a 4-year period at a tertiary psychiatric emergency service were reviewed. The collected data included socio-demographic and clinical variables and the Severity of Psychiatric Illness rating score. Psychiatric diagnosis was limited to information available in the emergency room given that a structured interview is not usually feasible in this setting. The diagnosis of borderline personality disorder was based on DSM-IV criteria. Immigrants were divided into five groups according to region of origin: North Africa, sub-Saharan Africa, South America, Asia and Western countries. Multivariate statistical logistic regression analysis showed that all subgroups of immigrants had a lower likelihood of being diagnosed with borderline personality disorder than the indigenous population independently of age and gender. Furthermore, the rates of borderline personality disorder diagnosis were considerably lower in Asian and sub-Saharan subgroups than in South American, North African, Western or native subgroups. Our results showed that in the psychiatric emergency service borderline personality disorder was diagnosed less frequently in the immigrant group v. the indigenous group. Our results do not support the concept of migration as a risk factor for borderline personality disorder.
Zanarini, Mary C.; Frankenburg, Frances R.; Wedig, Michelle M.; Fitzmaurice, Garrett M.
2013-01-01
Objective This study assesses three main types of cognition: nonpsychotic thought (odd thinking, unusual perceptual experiences, and non-delusional paranoia), quasi-psychotic thought, and true-psychotic thought in borderline patients followed prospectively for 16 years. It also compares the rates of these disturbed cognitions to those reported by axis II comparison subjects. Method The cognitive experiences of 362 inpatients—290 borderline patients and 72 axis II comparison subjects—were assessed at study entry using the cognitive section of the Revised Diagnostic Interview for Borderlines. Their cognitive experiences were reassessed every two years using the same interview. Results Each of the five main types of thought studied was reported by a significantly higher percentage of borderline patients than axis II comparison subjects over time. Each of these types of thought, except true-psychotic thought, declined significantly over time for those in both groups. Eleven of the 17 more specific forms of thought studied were also reported by a significantly higher percentage of borderline patients over the years of follow-up: magical thinking, overvalued ideas, recurrent illusions, depersonalization, derealization, undue suspiciousness, ideas of reference, other paranoid ideation, quasi-psychotic delusions, quasi-psychotic hallucinations, and true-psychotic hallucinations. Fourteen specific forms of thought were found to decline significantly over time for those in both groups: all forms of thought mentioned above except true-psychotic hallucinations plus marked superstitiousness, sixth sense, telepathy, and clairvoyance. Conclusions Disturbed cognitions are common among borderline patients and distinguishing for the disorder. They also decline substantially over time but remain a problem, particularly those of a nonpsychotic nature. PMID:23558452
Wieland, Jannelien; Haan, Sara Kapitein-de; Zitman, Frans G
2014-01-01
Objective: In the Netherlands, patients with borderline intellectual functioning are eligible for specialized mental health care. This offers the unique possibility to examine the mix of psychiatric disorders in patients who, in other countries, are treated in regular outpatient mental health care clinics. Our study sought to examine the rates of all main Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision, Axis I psychiatric diagnoses in outpatients with borderline intellectual functioning of 2 specialized regional psychiatric outpatient departments and to compare these with rates of the same disorders in outpatients from regular mental health care (RMHC) and outpatients with mild intellectual disabilities (IDs). Method: Our study was a cross-sectional, anonymized medical chart review. All participants were patients from the Dutch regional mental health care provider Rivierduinen. Diagnoses of patients with borderline intellectual functioning (borderline intellectual functioning group; n = 235) were compared with diagnoses of patients from RMHC (RMHC group; n = 1026) and patients with mild ID (mild ID group; n = 152). Results: Compared with the RMHC group, psychotic and major depressive disorders were less common in the borderline intellectual functioning group, while posttraumatic stress disorder and V codes were more common. Compared with the mild ID group, psychotic disorders were significantly less common. Conclusion: Mental health problems in people with borderline intellectual functioning may not be well addressed in general psychiatry, or by standard psychiatry for patients with ID. Specific attention to this group in clinical practice and research may be warranted lest they fall between 2 stools. PMID:25007114
Wieland, Jannelien; Kapitein-de Haan, Sara; Zitman, Frans G
2014-04-01
In the Netherlands, patients with borderline intellectual functioning are eligible for specialized mental health care. This offers the unique possibility to examine the mix of psychiatric disorders in patients who, in other countries, are treated in regular outpatient mental health care clinics. Our study sought to examine the rates of all main Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition, Text Revision, Axis I psychiatric diagnoses in outpatients with borderline intellectual functioning of 2 specialized regional psychiatric outpatient departments and to compare these with rates of the same disorders in outpatients from regular mental health care (RMHC) and outpatients with mild intellectual disabilities (IDs). Our study was a cross-sectional, anonymized medical chart review. All participants were patients from the Dutch regional mental health care provider Rivierduinen. Diagnoses of patients with borderline intellectual functioning (borderline intellectual functioning group; n = 235) were compared with diagnoses of patients from RMHC (RMHC group; n = 1026) and patients with mild ID (mild ID group; n = 152). Compared with the RMHC group, psychotic and major depressive disorders were less common in the borderline intellectual functioning group, while posttraumatic stress disorder and V codes were more common. Compared with the mild ID group, psychotic disorders were significantly less common. Mental health problems in people with borderline intellectual functioning may not be well addressed in general psychiatry, or by standard psychiatry for patients with ID. Specific attention to this group in clinical practice and research may be warranted lest they fall between 2 stools.
NASA Technical Reports Server (NTRS)
Kozlovsky, W. J.; Gustafson, E. K.; Eckardt, R. C.; Byer, R. L.
1988-01-01
With the advent of new nonlinear materials and single-frequency pump sources, there is renewed interest in optical parametric oscillators (OPOs). A single-mode diode-laser-pumped monolithic Nd:YAG nonplanar ring laser that is both amplified and frequency doubled is used to pump a monolithic MgO:LiNbO3 pulsed singly resonant OPO. The OPO signal output was temperature tuned from 834 to 958 nm, producing an idler tuning from 1.47 to 1.2 microns. Efforts toward a CW all-solid-state doubly resonant OPO are also described.
Design of a Mechanical NaK Pump for Fission Space Power Systems
NASA Technical Reports Server (NTRS)
Mireles, Omar R.; Bradley, David; Godfroy, Thomas
2010-01-01
Alkali liquid metal cooled fission reactor concepts are under development for mid-range spaceflight power requirements. One such concept utilizes a sodium-potassium eutectic (NaK) as the primary loop working fluid. Traditionally, linear induction pumps have been used to provide the required flow and head conditions for liquid metal systems but can be limited in performance. This paper details the design, build, and check-out test of a mechanical NaK pump. The pump was designed to meet reactor cooling requirements using commercially available components modified for high temperature NaK service.
Seasonal performance for Heat pump with vertical ground heat exchanger in Riga
NASA Astrophysics Data System (ADS)
Jaundālders, S.; Stanka, P.; Rusovs, D.
2017-10-01
Experimental measurements of Seasonal Coefficient of Performance (SCOP) for heating of 160 m2 household in Riga were conducted for operation of brine-water heat pump with vertical ground heat exchangers (GHE). Data regarding heat and electrical power consumption were recorded during three-year period from 2013 to 2016. Vapor compression heat pump has heat energy output of 8 kW. GHE consists of three boreholes. Each borehole is 60 m deep. Data regarding brine temperature for borehole input and output were presented and discussed. As far as house had floor heating, there were presented data about COP for B0/W35 and its dependence from room and outdoor temperature during heating season. Empirical equation was created. Average heat energy consumption during one year for heating was 72 kWh/m2 measured by heat meter. Detected primary energy consumption (electrical energy from grid) was 21 kWh/m2 which resulted in SCOP=3.8. These data were compared with SCOP for air-to-water heat pump in Latvia and available configuration software for heat pumps operation. Good agreement between calculated performance and reported experimental data were founded.
Howard, Rick; McCarthy, Lucy; Huband, Nick; Duggan, Conor
2013-07-01
Research suggests that a particular externalising phenotype, manifested in a developmental trajectory from severe childhood conduct disorder through early-onset substance abuse to adult antisocial/borderline personality disorder co-morbidity, may increase risk of antisocial behaviour in general and criminal recidivism in particular. This study aims to test the hypothesis that antisocial/borderline co-morbidity together with the triad of substance dependence, severe conduct disorder and borderline pathology would result in an increased risk of criminal recidivism. Fifty-three men who had been assessed and treated in a secure hospital unit were followed up after they had returned to the community. They were assessed for severity of the following: (i) antisocial personality disorder; (ii) borderline personality disorder; (iii) drug/alcohol dependence; and (iv) high Psychopathy Checklist Revised scores (factors 1 and 2). Patients with antisocial/borderline co-morbidity took significantly less time to re-offend compared with those without such co-morbidity. Both Psychopathy Checklist Revised factor 2 and the tripartite risk measure significantly predicted time to re-offence; the former largely accounted for the predictive accuracy of the latter. Risk of criminal recidivism can be adequately assessed without recourse to the pejorative term 'psychopath'. It is sufficient to assess the presence of the three elements of our risk measure: borderline and antisocial personality disorders in the context of drug/alcohol dependence and severe childhood conduct disorder. Practical implications of the study are as follows. (i) Sound assessment of personality, inclusive of a detailed history of childhood conduct disorder as well as adolescent and adult substance misuse, yields good enough information about risk of recidivism without recourse to the pejorative concept of 'psychopathy'. (ii) Given the high risk of alcohol-related violence in individuals with antisocial/borderline co-morbidity, there is a need for specific alcohol-directed interventions to help such men retain control of their substance use. Copyright © 2013 John Wiley & Sons, Ltd.
Optimal Energy Extraction From a Hot Water Geothermal Reservoir
NASA Astrophysics Data System (ADS)
Golabi, Kamal; Scherer, Charles R.; Tsang, Chin Fu; Mozumder, Sashi
1981-01-01
An analytical decision model is presented for determining optimal energy extraction rates from hot water geothermal reservoirs when cooled brine is reinjected into the hot water aquifer. This applied economic management model computes the optimal fluid pumping rate and reinjection temperature and the project (reservoir) life consistent with maximum present worth of the net revenues from sales of energy for space heating. The real value of product energy is assumed to increase with time, as is the cost of energy used in pumping the aquifer. The economic model is implemented by using a hydrothermal model that relates hydraulic pumping rate to the quality (temperature) of remaining heat energy in the aquifer. The results of a numerical application to space heating show that profit-maximizing extraction rate increases with interest (discount) rate and decreases as the rate of rise of real energy value increases. The economic life of the reservoir generally varies inversely with extraction rate. Results were shown to be sensitive to permeability, initial equilibrium temperature, well cost, and well life.
Efficiency analysis of semi-open sorption heat pump systems
Gluesenkamp, Kyle R.; Chugh, Devesh; Abdelaziz, Omar; ...
2016-08-10
Sorption systems traditionally fall into two categories: closed (heat pumps and chillers) and open (dehumidification). Recent work has explored the possibility of semi-open systems, which can perform heat pumping or chilling while utilizing ambient humidity as the working fluid of the cycle, and are still capable of being driven by solar, waste, or combustion heat sources. The efficiencies of closed and open systems are well characterized, and can typically be determined from four temperature s. In this work, the performance potential of semi-open systems is explored by adapting expressions for the efficiency of closed and open systems to the novelmore » semi-open systems. A key new parameter is introduced, which involves five temperatures, since both the ambient dry bulb and ambient dew point are used. Furthermore, this additional temperature is necessary to capture the open absorber performance in terms of both the absorption of humidity and sensible heat transfer with surrounding air.« less
Tunable CW diode-pumped Tm,Ho:YLiF4 laser operating at or near room temperature
NASA Technical Reports Server (NTRS)
Mcguckin, Brendan T. (Inventor); Menzies, Robert T. (Inventor)
1993-01-01
A conversion efficiency of 42 percent and slope efficiency of 60 percent relative to absorbed pump power are obtained from a continuous wave diode-pumped Tm,Ho:YLiF4 laser at 2 microns with output power of 84mW at a crystal temperature of 275K. The emission spectrum is etalon tunable over a range of 7nm (16.3 cm(sup -1) centered on 2.067 microns with fine tuning capability of the transition frequency with crystal temperature at a measured rate of -0.03/(cm)K. The effective emission cross-section is measured to be 5 x 10(sup -21) cm squared. These and other aspects of the laser performance are disclosed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications. Single frequency output and frequency stabilization are achieved using an intracavity etalon in conjunction with an external reference etalon.
Development of high temperature transport technology for LiCl-KCl eutectic salt in pyroprocessing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee, Sung Ho; Lee, Hansoo; Kim, In Tae
The development of high-temperature transport technologies for molten salt is a prerequisite and a key issue in the industrialization of pyro-reprocessing for advanced fuel cycle scenarios. The solution of a molten salt centrifugal pump was discarded because of the high corrosion power of a high temperature molten salt, so the suction pump solution was selected. An apparatus for salt transport experiments by suction was designed and tested using LiC-KCl eutectic salt. The experimental results of lab-scale molten salt transport by suction showed a 99.5% transport rate (ratio of transported salt to total salt) under a vacuum range of 100 mtorrmore » - 10 torr at 500 Celsius degrees. The suction system has been integrated to the PRIDE (pyroprocessing integrated inactive demonstration) facility that is a demonstrator using non-irradiated materials (natural uranium and surrogate materials). The performance of the suction pump for the transport of molten salts has been confirmed.« less
Bose-Einstein condensation of spin wave quanta at room temperature.
Dzyapko, O; Demidov, V E; Melkov, G A; Demokritov, S O
2011-09-28
Spin waves are delocalized excitations of magnetic media that mainly determine their magnetic dynamics and thermodynamics at temperatures far below the critical one. The quantum-mechanical counterparts of spin waves are magnons, which can be considered as a gas of weakly interacting bosonic quasi-particles. Here, we discuss the room-temperature kinetics and thermodynamics of the magnon gas in yttrium iron garnet films driven by parametric microwave pumping. We show that for high enough pumping powers, the thermalization of the driven gas results in a quasi-equilibrium state described by Bose-Einstein statistics with a non-zero chemical potential. Further increases of the pumping power cause a Bose-Einstein condensation documented by an observation of the magnon accumulation at the lowest energy level. Using the sensitivity of the Brillouin light scattering spectroscopy to the degree of coherence of the scattering magnons, we confirm the spontaneous emergence of coherence of the magnons accumulated at the bottom of the spectrum, occurring if their density exceeds a critical value.
Tian, Jing; Guo, Shi-Rong; Sun, Jin; Wang, Li-Ping; Yang, Yan-Juan; Li, Bin
2011-12-01
Taking a relatively heat-resistant cucumber (Cucumis sativus) cultivar 'Jinchun No. 4' as test material, a sand culture experiment was conducted in growth chamber to investigate the effects of foliar spraying spermidine (Spd) on the lipid peroxidation, membrane proton pump activity, and corresponding gene expression of cucumber seedling leaves under high temperature stress. Compared with the control, foliar spraying Spd increased the plant height, stem diameter, dry and fresh mass, and leaf area significantly, and inhibited the increase of leaf relative conductivity, malondialdehyde (MDA) content, and lipoxygenase (LOX) activity effectively. Foliar spraying Spd also helped to the increase of leaf plasma membrane- and tonoplast H(+)-ATPase activity, but no significant difference was observed in the gene expression levels. These results suggested that exogenous Spd could significantly decrease the leaf lipid peroxidation and increase the proton pump activity, and thus, stabilize the leaf membrane structure and function, alleviate the damage induced by high temperature stress, and enhance the heat tolerance of cucumber seedlings.
NASA Astrophysics Data System (ADS)
Brenier, A.; Alombert-Goget, G.; Guyot, Y.; Boulon, G.
2012-10-01
The absorption and fluorescence properties of the Nd-doped YGd2Sc2Al2GaO12 mixed garnet ceramics have been measured at different temperatures. Under laser diode pumping an efficient laser emission has been demonstrated with 45% slope efficiency. The emission is constituted by two lines at 1058.6 and 1061.3 nm, subjected to a red shift and a variable relative intensity versus pump power. The role of the temperature has been investigated playing with the cavity parameters. The thermal conductivity of the 1% Nd-doped material has been determined (3.2 W/m/K) measuring the radial temperature distribution of the exit face of the sample including the axial heat flow in the analysis. The M2 beam quality factor and the dioptric power of the thermal lens have been investigated versus the pump power. The thermo-optic coefficient χ was determined as 44.4×10-6 K-1.
Efficiency analysis of semi-open sorption heat pump systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gluesenkamp, Kyle R.; Chugh, Devesh; Abdelaziz, Omar
Sorption systems traditionally fall into two categories: closed (heat pumps and chillers) and open (dehumidification). Recent work has explored the possibility of semi-open systems, which can perform heat pumping or chilling while utilizing ambient humidity as the working fluid of the cycle, and are still capable of being driven by solar, waste, or combustion heat sources. The efficiencies of closed and open systems are well characterized, and can typically be determined from four temperature s. In this work, the performance potential of semi-open systems is explored by adapting expressions for the efficiency of closed and open systems to the novelmore » semi-open systems. A key new parameter is introduced, which involves five temperatures, since both the ambient dry bulb and ambient dew point are used. Furthermore, this additional temperature is necessary to capture the open absorber performance in terms of both the absorption of humidity and sensible heat transfer with surrounding air.« less
The effects of oxytocin on social cognition in borderline personality disorder.
Servan, A; Brunelin, J; Poulet, E
2018-02-01
Deficits in social cognition and interpersonal difficulties are key features in borderline personality disorder. Social cognition refers to the function of perceiving and adequately dealing with social signals, leading to the establishment and maintenance of healthy and positive social relationships. Evidence suggests that oxytocin (OT) may improve social cognition and human social behavior. Recently, several studies have highlighted the beneficial effects of oxytocin in several psychiatric conditions involving social cognition deficits such as schizophrenia, autism or social phobia. However, despite growing interest, the effects of oxytocin in patients with borderline personality disorder are far from being clearly demonstrated. The objective of this work was to review and discuss studies investigating the interest of oxytocin in alleviating social cognition deficits in patients with borderline personality disorder (recognition of emotion, trust and cooperation, affective and cognitive empathy, emotional expression and social problem-solving). A systematic review of the literature was conducted up to September 31, 2016 on the Pubmed, Science direct, Medline and Scopus databases using "borderline personality disorder" and "oxytocin" as keywords. To be included, studies were to include patients with borderline personality disorder; to investigate social cognition and to investigate the effect of oxytocin on social cognition in patients with TPB. The initial search yielded 52 articles. Among them, 11 studies were selected according to the PRISMA criteria. The effect of oxytocin on social cognition in patients with borderline personality disorder was mainly investigated in relation to recognition of emotions and trust and cooperation. We did not find any studies investigating the effect of oxytocin on affective and cognitive empathy, emotional expression or social problem-solving abilities. In patients with borderline personality disorder, oxytocin had a beneficial impact on recognition and discrimination of emotions and on hypervigilance towards social threats. However, oxytocin could hinder trust and cooperation. These data lead us to consider oxytocin as a treatment for emotion recognition deficit and hypervigilance towards social threats in borderline personality disorder. A beneficial effect of oxytocin of this nature may be obtained only in patients without deficits in trust and cooperation because of a risk of aggravating relational instability. There was no current evidence for the interest of oxytocin in enhancing affective and cognitive empathy in borderline personality disorder. Further studies are needed to evaluate the clinical interest of combining oxytocin with psychotherapeutic approaches such as dialectical behavioral therapy or mentalisation-based treatment. Copyright © 2017. Published by Elsevier Masson SAS.
Franchi, Dorella; Boveri, Sara; Radice, Davide; Portuesi, Rosalba; Zanagnolo, Vanna; Colombo, Nicoletta; Testa, Antonia Carla
2016-12-01
Borderline ovarian tumors are generally diagnosed in young women. Because of the young age of patients at first diagnosis and at recurrence, and given the good prognosis of borderline ovarian tumors, a conservative surgical approach in those women who wish to preserve their fertility is advised. In this scenario, transvaginal ultrasound examination plays a key role in the detection of borderline ovarian tumor recurrence, and in assessment of amount of normal functioning parenchyma remaining. To date, no data are available about the natural history of borderline ovarian tumor recurrence. The aim of the study was to determine growth rate of recurrent ovarian cysts by a scheduled follow-up by ultrasound examination, in women previously treated with fertility-sparing surgery due to borderline ovarian tumors. In this prospective observational study, we collected data from 34 patients previously treated with fertility-sparing surgery due to borderline ovarian tumors, who had a suspicious recurrent lesion. The patients underwent transvaginal ultrasonographic examination every 3 months, until the clinical setting recommended proceeding with surgery. According to cyst size at study entry, they were categorized into 3 groups: ≤10 mm, 10-20 mm, and >20 mm. Summary statistics for cyst size, growth rate, and the probability of remaining within the same dimension category at first ultrasound during the follow-up were also obtained. For each cyst the growth rate was calculated as the slope of the linear interpolation between 2 consecutive measurements. Follow-up timing (P < .001), cyst size (P < .001), and micropapillary pattern (P < .001) were factors significantly affecting the cyst growth both in univariate and multivariate analysis. According to size category at first ultrasound, growth rate ranges from a minimum of 0.06 mm/mo for cysts <10 mm up to 1.92 mm/mo for cysts >20 mm. The final histology of all recurrent lesions confirmed the same histotype of primary borderline ovarian tumors. This article represents the first observational study that describes the trend in the growth rate of borderline ovarian tumor recurrence in relation to their size detected at the first ultrasound examination. The findings of this study seem to confirm, in selected patients, that a thorough ultrasonographic follow-up of borderline ovarian tumor recurrence has proven to be safe and feasible. The final goal of such management is to maximize the impact on fertility potential of these young women without worsening their prognosis. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Hong; Duan, Huanlin; Chen, Aidong
2018-02-01
In this paper, the mine-water source heat pump system is proposed in residential buildings of a mining community. The coefficient of performance (COP) and the efficiency of exergy are analyzed. The results show that the COP and exergy efficiency of the mine-water source heat pump are improved, the exergy efficiency of mine-water source heat pump is more than 10% higher than that of the air source heat pump.The electric power conservation measure of “peak load shifting” is also emphasized in this article. It shows that itis a very considerable cost in the electric saving by adopting the trough period electricity to produce hot water. Due to the proper temperature of mine water, the mine-watersource heat pump unit is more efficient and stable in performance, which further shows the advantage of mine-water source heat pump in energy saving and environmental protection. It provides reference to the design of similar heat pump system as well.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klett, James; Klett, Lynn
An apparatus for maintaining the temperature of an article at a temperature that is below the ambient air temperature includes an enclosure having an outer wall that defines an interior chamber for holding a volume of sealed air. An insert is disposed inside of the chamber and has a body that is made of a porous graphite foam material. A vacuum pump penetrates the outer wall and fluidly connects the sealed air in the interior chamber with the ambient air outside of the enclosure. The temperatures of the insert and article is maintained at temperatures that are below the ambientmore » air temperature when a volume of a liquid is wicked into the pores of the porous insert and the vacuum pump is activated to reduce the pressure of a volume of sealed air within the interior chamber to a pressure that is below the vapor pressure of the liquid.« less
14 CFR 29.1433 - Vacuum systems.
Code of Federal Regulations, 2010 CFR
2010-01-01
... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Equipment Miscellaneous Equipment § 29.1433 Vacuum systems. (a... the discharge lines from the vacuum air pump when the delivery temperature of the air becomes unsafe. (b) Each vacuum air system line and fitting on the discharge side of the pump that might contain...
Proposed low-temperature solar engine
NASA Technical Reports Server (NTRS)
Peoples, J. A.; Kearns, G. B.
1976-01-01
Engine, proposed for conversion of Sun's heat to motion without need for heat pumps and associated equipment, uses expansion and contraction of aluminum rod to drive tow out-of-phase windlasses. Linear displacement of 0.076 cm in rod will exert sufficient force to drive pumps, generators, and compressors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Savanier, Marc, E-mail: msavanier@eng.ucsd.edu; Kumar, Ranjeet; Mookherjea, Shayan, E-mail: smookherjea@eng.ucsd.edu
Silicon photonic microchips may be useful for compact, inexpensive, room-temperature optically pumped photon-pair sources, which unlike conventional photon-pair generators based on crystals or optical fibers, can be manufactured using CMOS-compatible processes on silicon wafers. It has been shown that photon pairs can be created in simple structures such as microring resonators at a rate of a few hundred kilohertz using less than a milliwatt of optical pump power, based on the process of spontaneous four-wave mixing. To create a practical photon-pair source, however, also requires some way of monitoring the device and aligning the pump wavelength when the temperature varies,more » since silicon resonators are highly sensitive to temperature. In fact, monitoring photodiodes are standard components in classical laser diodes, but the incorporation of germanium or InGaAs photodiodes would raise the cost and fabrication complexity. Here, we present a simple and effective all-electronic technique for finding the optimum operating point for the microring used to generate photon pairs, based on measuring the reverse-biased current in a silicon p-i-n junction diode fabricated across the waveguide that constitutes the silicon microring. We show that by monitoring the current, and using it to tune the pump laser wavelength, the photon-pair generation properties of the microring can be preserved over a temperature range of more than 30 °C.« less
NASA Technical Reports Server (NTRS)
Schoenfeld, Michael P.; Webster, Kenny L.; Pearson, Boise Jon
2013-01-01
As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz. Keywords: fission, space power, nuclear, liquid metal, NaK.
Efficient CW diode-pumped Tm, Ho:YLF laser with tunability near 2.067 microns
NASA Technical Reports Server (NTRS)
Mcguckin, B. T.; Menzies, Robert T.
1992-01-01
A conversion efficiency of 42 percent and slope efficiency of approximately 60 percent relative to absorbed pump power are reported from a continuous wave diode-pumped Tm, Ho:YLF laser at 2 microns with output power of 84 mW at sub-ambient temperatures. The emission spectrum is etalon tunable over a range of 16/cm centered on 2.067 microns, with fine tuning capability of the transition frequency with crystal temperature at a measured rate of about -0.03/cm-K. The effective emission cross section is measured to be 5 x 10 exp -21 sq cm. These and other aspects of the laser performance are discussed in the context of calculated atmospheric absorption characteristics in this spectral region and potential use in remote sensing applications.
Cryogenic cooling for high power laser amplifiers
NASA Astrophysics Data System (ADS)
Perin, J. P.; Millet, F.; Divoky, M.; Rus, B.
2013-11-01
Using DPSSL (Diode Pumped Solid State Lasers) as pumping technology, PW-class lasers with enhanced repetition rates are developed. Each of the Yb YAG amplifiers will be diode-pumped at a wavelength of 940 nm. This is a prerequisite for achieving high repetition rates (light amplification duration 1 millisecond and repetition rate 10 Hz). The efficiency of DPSSL is inversely proportional to the temperature, for this reason the slab amplifier have to be cooled at a temperature in the range of 100 K-170 K with a heat flux of 1 MW*m-2. This paper describes the thermo-mechanical analysis for the design of the amplification laser head, presents a preliminary proposal for the required cryogenic cooling system and finally outlines the gain of cryogenic operation for the efficiency of high pulsed laser.
Apparatus for generating coherent infrared energy of selected wavelength
Stevens, C.G.
A tunable source of coherent infrared energy includes a heat pipe having an intermediate region at which cesium is heated to vaporizing temperature and end regions at which the vapor is condensed and returned to the intermediate region for reheating and recirculation. Optical pumping light is directed along the axis of the heat pipe through a first end window to stimulate emission of coherent infrared energy which is transmitted out through an opposite end window. A porous walled tubulation extends along the axis of the heat pipe and defines a region in which cesium vapor is further heated to a temperature sufficient to dissociate cesium dimers which would decrease efficiency by absorbing pump light. Efficient generation of any desired infrared wavelength is realized by varying the wavelength of the pump light.
Testing of Liquid Metal Components for Nuclear Surface Power Systems
NASA Technical Reports Server (NTRS)
Polzin, Kurt A.; Godfroy, Thomas J.; Pearson, J. Boise
2010-01-01
The Early Flight Fission Test Facility (EFF-TF) was established by the Marshall Space Flight Center (MSFC) to provide a capability for performing hardware-directed activities to support multiple in-space nuclear reactor concepts by using a non-nuclear test methodology. This includes fabrication and testing at both the module/component level and near prototypic reactor configurations. The EFF-TF is currently supporting an effort to develop an affordable fission surface power (AFSP) system that could be deployed on the Lunar surface. The AFSP system is presently based on a pumped liquid metal-cooled (Sodium-Potassium eutectic, NaK-78) reactor design. This design was derived from the only fission system that the United States has deployed for space operation, the Systems for Nuclear Auxiliary Power (SNAP) 10A reactor, which was launched in 1965. Two prototypical components recently tested at MSFC were a pair of Stirling power conversion units that would be used in a reactor system to convert heat to electricity, and an annular linear induction pump (ALIP) that uses travelling electromagnetic fields to pump the liquid metal coolant through the reactor loop. First ever tests were conducted at MSFC to determine baseline performance of a pair of 1 kW Stirling convertors using NaK as the hot side working fluid. A special test rig was designed and constructed and testing was conducted inside a vacuum chamber at MSFC. This test rig delivered pumped NaK for the hot end temperature to the Stirlings and water as the working fluid on the cold end temperature. These test were conducted through a hot end temperature range between 400 to 550C in increments of 50 C and a cold end temperature range from 30 to 70 C in 20 C increments. Piston amplitudes were varied from 6 to 1 1mm in .5 mm increments. A maximum of 2240 Watts electric was produced at the design point of 550 hot end, 40 C cold end with a piston amplitude of 10.5mm. This power level was reached at a gross thermal efficiency of 28%. A baseline performance map was established for the pair of 1kW Stirling convertors. The performance data will then be used for design modification to the Stirling convertors. The ALIP tested at MSFC has no moving parts and no direct electrical connections to the liquid metal containing components. Pressure is developed by the interaction of the magnetic field produced by the stator and the current which flows as a result of the voltage induced in the liquid metal contained in the pump duct. Flow is controlled by variation of the voltage supplied to the pump windings. Under steady-state conditions, pump performance is measured for flow rates from 0.5-4.3 kg/s. The pressure rise developed by the pump to support these flow rates is roughly 5-65 kPa. The RMS input voltage (phase-to-phase voltage) ranges from 5-120 V, while the frequency can be varied arbitrarily up to 60 Hz. Performance is quantified at different loop temperature levels from 50 C up to 650 C, which is the peak operating temperature of the proposed AFSP reactor. The transient response of the pump is also evaluated to determine its behavior during startup and shut-down procedures.
Thermal analysis of heat and power plant with high temperature reactor and intermediate steam cycle
NASA Astrophysics Data System (ADS)
Fic, Adam; Składzień, Jan; Gabriel, Michał
2015-03-01
Thermal analysis of a heat and power plant with a high temperature gas cooled nuclear reactor is presented. The main aim of the considered system is to supply a technological process with the heat at suitably high temperature level. The considered unit is also used to produce electricity. The high temperature helium cooled nuclear reactor is the primary heat source in the system, which consists of: the reactor cooling cycle, the steam cycle and the gas heat pump cycle. Helium used as a carrier in the first cycle (classic Brayton cycle), which includes the reactor, delivers heat in a steam generator to produce superheated steam with required parameters of the intermediate cycle. The intermediate cycle is provided to transport energy from the reactor installation to the process installation requiring a high temperature heat. The distance between reactor and the process installation is assumed short and negligable, or alternatively equal to 1 km in the analysis. The system is also equipped with a high temperature argon heat pump to obtain the temperature level of a heat carrier required by a high temperature process. Thus, the steam of the intermediate cycle supplies a lower heat exchanger of the heat pump, a process heat exchanger at the medium temperature level and a classical steam turbine system (Rankine cycle). The main purpose of the research was to evaluate the effectiveness of the system considered and to assess whether such a three cycle cogeneration system is reasonable. Multivariant calculations have been carried out employing the developed mathematical model. The results have been presented in a form of the energy efficiency and exergy efficiency of the system as a function of the temperature drop in the high temperature process heat exchanger and the reactor pressure.
The buffer role of meaning in life in hopelessness in women with borderline personality disorders.
Marco, José H; Guillén, Veronica; Botella, Cristina
2017-01-01
Meaning in life has been found to be a protective factor against suicidal ideation. The aim of this study was to investigate whether meaning in life can moderate and buffer the association between suicide risk factors and hopelessness in women with borderline personality disorders. One hundred twenty-four women diagnosed with borderline personality disorder completed self-report measures of suicide risk factors, hopelessness, and meaning in life. The main result from this study was that meaning in life moderated the association between suicide risk factors and hopelessness. Meaning in life is an important variable in the prevention and treatment of risk of suicide in women with borderline personality disorder. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Effects of dysthymia on personality assessment.
Lecic-Tosevski, D; Divac-Jovanovic, M
1996-01-01
Twenty-eight dysthymic patients (82.1% with personality disorders) were investigated with questionnaires for personality and depression before and after treatment. When in asymptomatic state, defined by clinical criteria and HAM-D score 6 or lower, the personality profile of 15 patients (group I) was significantly changed from the one before treatment (avoidant, passive-aggressive, borderline and schizotypal dimensions were lower, and narcissistic dimension higher [P < 0.01]). Thirteen patients (group II) had an unchanged profile. The first group showed significant state-trait dependence, especially of the borderline personality dimension. The second group manifested a permanent characterological affective syndrome, or a core borderline personality disorder. The limitations of personality assessment during affective episodes are discussed as well as the borderline level of functioning related to it.
Preliminary Design of the Vacuum System for FAIR Super FRS Quadrupole Magnet Cryostat
NASA Astrophysics Data System (ADS)
Akhter, J.; Pal, G.; Datta, A.; Sarma, P. R.; Bhunia, U.; Roy, S.; Bhattacharyya, S.; Nandi, C.; Mallik, C.; Bhandari, R. K.
2012-11-01
The Super-Conducting Fragment Separator (Super FRS) of the Facility for Antiproton and Ion Research (FAIR) at GSI Darmstadt is a large-acceptance superonducting fragment separator. The separator consists of large dipole, quadrupole and hexapole superconducting magnets. The long quadrupole magnet cryostat houses the helium chamber, which has the magnet iron and NbTi superconducting coil. The magnet weighs about 30 tons. The helium chamber is enclosed in vacuum inside the magnet cryostat. Multilayer Insulation (MLI) will be wrapped around the thermal shield to reduce radiation loss. Polyster of MLI comprises the major component responsible for outgassing. In order to reduce outgassing, pumping at elevated temperatures has to be carried out. In view of the large size and weight of the magnet, a seal off approach might not be operationally feasible. Continuous pumping of the cryostat has also been examined. Pump has been kept at a distance from the magnet considering the effect of stray magnetic fields. Oil free turbo molecular pump and scroll pump combination will be used to pump down the cryostat. The ultimate heat load of the cryostat will be highly dependent on the pressure attained. Radiation and conduction plays an important role in the heat transfer at low temperatures. This paper presents the vacuum design of the long quadrupole magnet cryostat and estimates the heat load of the cryostat.
Returning to work while breastfeeding.
Biagioli, Frances
2003-12-01
Mothers who work outside the home initiate breastfeeding at the same rate as mothers who stay at home. However, the breastfeeding continuance rate declines sharply in mothers who return to work. While the work environment may be less than ideal for the breastfeeding mother, obstacles can be overcome. Available breast pump types include manual pumps, battery-powered pumps, electric diaphragm pumps, electric piston pumps, and hospital-grade electric piston pumps. Electric piston pumps may be the most suitable type for mothers who work outside the home for more than 20 hours per week; however, when a mother is highly motivated, any pump type can be successful in any situation. Conservative estimates suggest that breast milk can be stored at room temperature for eight hours, refrigerated for up to eight days, and frozen for many months. A breastfeeding plan can help the working mother anticipate logistic problems and devise a practical pumping schedule. A mother's milk production usually is well established by the time her infant is four weeks old; it is best to delay a return to work until at least that time, and longer if possible.
Electromagnetic Pumps for Conductive-Propellant Feed Systems
NASA Technical Reports Server (NTRS)
Markusic, Thomas E.; Polzin, Kurt A.; Dehoyos, Amado
2005-01-01
Prototype electromagnetic pumps for use with lithium and bismuth propellants were constructed and tested. Such pumps may be used to pressurize future electric propulsion liquid metal feed systems, with the primary advantages being the compactness and simplicity versus alternative pressurization technologies. Design details for two different pumps are described: the first was designed to withstand (highly corrosive) lithium propellant, and t he second was designed to tolerate the high temperature required to pump liquid bismuth. Both qualitative and quantitative test results are presented. Open-loop tests demonstrated the capability of each device to electromagnetically pump its design propellant (lithium or bismuth). A second set of tests accurately quantified the pump pressure developed as a function of current. These experiments, which utilized a more easily handled material (gallium), demonstrated continuously-adjustable pump pressure levels ranging from 0-100 Torr for corresponding input current levels of 0-75 A. While the analysis and testing in this study specifically targeted lithium and bismuth propellants, the underlying design principles should be useful in implementing liquid metal pumps in any conductive-propellant feed system.
Experimental study of operation performance for hydrocarbon fuel pump with low specific speed
NASA Astrophysics Data System (ADS)
Wu, Xianyu; Yang, Jun; Jin, Xuan
2017-10-01
In this paper, a small flow rate hydrocarbon turbine pump was used to pressurize the fuel supply system of scramjet engine. Some experiments were carried out to investigate the characteristics of turbine pump driven by nitrogen or combustion gas under different operating conditions. A experimental database with regard to the curves of the rotational speed, mass flow rate and net head with regard to centrifugal pump were plotted. These curves were represented as functions of the pressure and temperature at turbine inlet/outlet and the throttle diameter at downstream of centrifugal pump. A sensitivity study has been carried out based on design of experiments. The experimental was employed to analyze net head of centrifugal and throttle characteristics. The research results can accumulate foundations for the close loop control system of turbine pump.
Uncooled pump combiners for fiber laser and amplifier systems
NASA Astrophysics Data System (ADS)
Bansal, L.; Sienkowski, R.; Neale, C.; Mann, J.; Headley, C.
2018-02-01
In this work we demonstrate a high transmission pump combiner that can operate uncooled at a maximum power of 400W for a continuous duration of 100hrs. The 7x1 pump combiner has seven 105/125 μm diameter 0.22 NA input pump fibers and a 247 μm diameter and 0.22 NA glass clad output fiber. The combiner has a high, 99%, pump transmission efficiency. These devices withstand without failure, a series of environmental stress tests, namely Thermal Cycling (-40 to 85ºC) and Damp Humidity (85ºC/85RH). These tests are conducted to uncover any latent defects in the device structure. The combiner's also survive an elevated temperature of 75ºC at a power of 365W for duration of 5hrs, without any noticeable change in pump transmission.
Resonantly diode-pumped Er:YAG laser: 1470-nm versus 1530-nm CW pumping case
NASA Astrophysics Data System (ADS)
Kudryashov, Igor; Ter-Gabrielyan, Nikolai; Dubinskii, Mark
2009-05-01
Growing interest to high power lasers in the eye-safe spectral domain initiated a new wave of activity in developing solid-state lasers based on bulk Er3+-doped materials. The resonant pumping of SSL allows for shifting significant part of thermal load from gain medium itself to the pump diodes, thus greatly reducing gain medium thermal distortions deleterious to SSL power scaling with high beam quality. The two major resonant pumping bands in Er:YAG are centered around 1470 and 1532 nm. Pumping into each of these bands has its pros and contras. The best approach to resonant pumping of Er:YAG active media in terms of pump wavelength is yet to be determined. We report the investigation results of high power diode-pumped Er:YAG laser aimed at direct comparison of resonant pumping at 1470 and 1532 nm. Two sources used for pumping were: 1530-nm 10-diode bar stack (>300 W CW) and 1470-nm 10-diode bar stack (>650 W CW). Both pumps were spectrally narrowed by external volume Bragg gratings. The obtained spectral width of less than 1 nm allowed for 'in-line' pumping of Er3+ in either band. The obtained CW power of over 87 W is, to the best of our knowledge, the record high power reported for resonantly pumped Er:YAG DPSSL at room temperature.
Theoretical study on the thermal and optical features of a diode side-pumped alkali laser
NASA Astrophysics Data System (ADS)
Han, Juhong; Liu, Xiaoxu; Wang, Hongyuan; Cai, He; An, Guofei; Zhang, Wei; Wang, You
2018-03-01
As one of the most hopeful candidates to achieve high power performances, a diode-pumped alkali laser (DPAL) has attracted a lot of attention in the last decade. Comparing with a diode end-pumped alkali laser (DEPAL), a diode side-pumped alkali laser (DSPAL) has great potentiality to realize an even-higher output of alkali lasers. However, there are few related researching studies concern DSPAL. In this paper, we introduce a theoretical model to investigate the physical features of a double-directions side-pumped alkali laser. The distributions of the population density, temperature, and absorption power at the cross section of a vapor cell are systematically studied. The analyses should be valuable for design of a steady high-powered DPAL.
High-energy directly diode-pumped Q-switched 1617 nm Er:YAG laser at room temperature.
Wang, Mingjian; Zhu, Liang; Chen, Weibiao; Fan, Dianyuan
2012-09-01
We describe high-energy Erbium-doped yttrium aluminum garnet (Er:YAG) lasers operating at 1617 nm, resonantly pumped using 1532 nm fiber-coupled laser diodes. A maximum continuous wave output power of 4.3 W at 1617 nm was achieved with an output coupler of 20% transmission under incident pump power of 29.7 W, resulting in an optical conversion of 14% with respect to the incident pump power. In Q-switched operation, the pulse energy of 11.8 mJ at 100 Hz pulse repetition frequency and 81 ns pulse duration was obtained. This energy is the highest pulse energy reported for a directly diode-pumped Q-switched Er:YAG laser operating at 1617 nm.
Mold Heating and Cooling Pump Package Operator Interface Controls Upgrade
DOE Office of Scientific and Technical Information (OSTI.GOV)
Josh A. Salmond
2009-08-07
The modernization of the Mold Heating and Cooling Pump Package Operator Interface (MHC PP OI) consisted of upgrading the antiquated single board computer with a proprietary operating system to off-the-shelf hardware and off-the-shelf software with customizable software options. The pump package is the machine interface between a central heating and cooling system that pumps heat transfer fluid through an injection or compression mold base on a local plastic molding machine. The operator interface provides the intelligent means of controlling this pumping process. Strict temperature control of a mold allows the production of high quality parts with tight tolerances and lowmore » residual stresses. The products fabricated are used on multiple programs.« less
Cavitation characteristics of a small centrifugal pump in He I and He II
NASA Technical Reports Server (NTRS)
Ludtke, P. R.; Daney, D. E.
1988-01-01
The cavitation characteristics of a small preinduced centrifugal pump operating in He I and He II over the temperature range 1.8-4.2 K are presented. The pump and close-coupled induction motor operate immersed in liquid helium. A six-blade propeller inducer and a three-blade screw inducer were both tested. With this pump configuration using either inducer, there is a tremendous difference between the cavitation characteristics of He I and He II. The net positive suction head requirements for this pump with the screw inducer could not be determined for He I, but it is less than -100 mm and, depending on flow rate, ranges between 35 and 165 mm for He II.
Ground-Source Heat Pumps | Climate Neutral Research Campuses | NREL
cooling requirements and heating loads. GSHPs take advantage of moderate soil temperatures available year Are ground-source heat pumps right for your campus? Are soil conditions suitable? Are heating and consider the following before undertaking an assessment or GSHP installation. Suitable Soil Conditions The
Coupled dual loop absorption heat pump
Sarkisian, Paul H.; Reimann, Robert C.; Biermann, Wendell J.
1985-01-01
A coupled dual loop absorption system which utilizes two separate complete loops. Each individual loop operates at three temperatures and two pressures. This low temperature loop absorber and condenser are thermally coupled to the high temperature loop evaporator, and the high temperature loop condenser and absorber are thermally coupled to the low temperature generator.
Li, Hui-Ying; Liu, Yun-Fei; Duan, Yu; Yang, Yong-Qiang; Lu, Yi-Nan
2015-01-01
Preparation of dense alumina (Al2O3) thin film through atomic layer deposition (ALD) provides a pathway to achieve the encapsulation of organic light emitting devices (OLED). Unlike traditional ALD which is usually executed at higher reaction n temperatures that may affect the performance of OLED, this application discusses the development on preparation of ALD thin film at a low temperature. One concern of ALD is the suppressing effect of ambient temperature on uniformity of thin film. To mitigate this issue, the pumping time in each reaction cycle was increased during the preparation process, which removed reaction byproducts and inhibited the formation of vacancies. As a result, the obtained thin film had both high uniformity and density properties, which provided an excellent encapsulation performance. The results from microstructure morphology analysis, water vapor transmission rate, and lifetime test showed that the difference in uniformity between thin films prepared at low temperatures, with increased pumping time, and high temperatures was small and there was no obvious influence of increased pumping time on light emitting performance. Meanwhile, the permeability for water vapor of the thin film prepared at a low temperature was found to reach as low as 1.5 × 10−4 g/(m2·day) under ambient conditions of 25 °C and 60% relative humidity, indicating a potential extension in the lifetime for the OLED. PMID:28787960