Sample records for bottom substate monitoring

  1. View west of load dispatch model board; section covers substations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west of load dispatch model board; section covers substations from edgerly (right) to thorndale and west yard (left). Instruments at bottom of center board section formerly monitored energy usage and were replaced by a computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  2. Design of online monitoring and forecasting system for electrical equipment temperature of prefabricated substation based on WSN

    NASA Astrophysics Data System (ADS)

    Qi, Weiran; Miao, Hongxia; Miao, Xuejiao; Xiao, Xuanxuan; Yan, Kuo

    2016-10-01

    In order to ensure the safe and stable operation of the prefabricated substations, temperature sensing subsystem, temperature remote monitoring and management subsystem, forecast subsystem are designed in the paper. Wireless temperature sensing subsystem which consists of temperature sensor and MCU sends the electrical equipment temperature to the remote monitoring center by wireless sensor network. Remote monitoring center can realize the remote monitoring and prediction by monitoring and management subsystem and forecast subsystem. Real-time monitoring of power equipment temperature, history inquiry database, user management, password settings, etc., were achieved by monitoring and management subsystem. In temperature forecast subsystem, firstly, the chaos of the temperature data was verified and phase space is reconstructed. Then Support Vector Machine - Particle Swarm Optimization (SVM-PSO) was used to predict the temperature of the power equipment in prefabricated substations. The simulation results found that compared with the traditional methods SVM-PSO has higher prediction accuracy.

  3. Substation alarm multiplexing system (SAMS)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ElBadaly, H.; Gaughan, J.; Ward, G.

    1996-03-01

    This paper describes an on going R&D project to develop, design, install, and assess the field performance of an advanced substation alarm system. SAMS provides a highly fault-tolerant system for the reporting of equipment alarms. SAMS separates and identifies each of the multiple alarm contacts, transmits an alarm condition over existing substation two-wire system, and displays the alarm source, and its associated technical information, on a touch-screen monitor inside the substation control room, and a remote central location and on a hand held terminal which may be carried anywhere within the substation. SAMS is currently installed at the Sherman Creekmore » substation in the Bronx for the purpose of a three month field evaluation.« less

  4. The power grid monitoring promotion of Liaoning December 14th accident

    NASA Astrophysics Data System (ADS)

    Zhou, Zhi; Gao, Ziji; He, Xiaoyang; Li, Tie; Jin, Xiaoming; Wang, Mingkai; Qu, Zhi; Sun, Chenguang

    2018-02-01

    This paper introduces the main responsibilities of power grid monitoring and the accident of Liaoning Power Grid 500kV Xujia transformer substation at December 14th, 2016. This paper analyzes the problems exposed in this accident from the aspects of abnormal information judgment, fault information collection, auxiliary video monitoring, online monitoring of substation equipment, puts forward the corresponding improvement methods and summarizes the methods of improving the professional level of power grid equipment monitoring.

  5. 76 FR 53437 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... a matrix on the bottom of the river; (2) the total capacity of the installation would be up to 35,000 kilowatts; (3) shielded underwater cables would convey each matrix power to a substation; and (4...

  6. 76 FR 53430 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14076-000 would consist of: (1) Up to 376 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  7. 76 FR 53435 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14089-000 would consist of: (1) Up to 260 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  8. 76 FR 53436 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14091-000 would consist of: (1) Up to 400 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  9. 76 FR 53443 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... would consist of the following: (1) Up to 120 TREK generating units installed in a matrix on the bottom...) shielded underwater cables would convey each matrix power to a substation; and (4) a transmission line...

  10. 76 FR 53434 - Free Flow Power Corporation, Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...) Up to 160 TREK generating units installed in a matrix on the bottom of the river; (2) the total... each matrix power to a substation; and (4) a transmission line would interconnect with the power grid...

  11. 76 FR 53433 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...-000 would consist of: (1) Up to 400 TREK generating units installed in a matrix on the bottom of the... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  12. 76 FR 53436 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14090-000 would consist of: (1) Up to 200 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix's power to a substation; and (4) a transmission line would...

  13. 76 FR 53427 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14074-000 would consist of: (1) Up to 376 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  14. 76 FR 53438 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14081-000 would consist of: (1) Up to 50 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  15. 76 FR 53434 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14093-000 would consist of: (1) Up to 160 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  16. 76 FR 53431 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14072-000 would consist of: (1) Up to 150 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  17. 76 FR 53443 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... of the following: (1) Up to 75 TREK generating units installed in a matrix on the bottom of the river... cables would convey each matrix power to a substation; and (4) a transmission line would interconnect...

  18. 76 FR 53427 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14092-000 would consist of: (1) Up to 180 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  19. 76 FR 53432 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14099-000 would consist of: (1) Up to 380 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  20. 76 FR 53438 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    .... 14096-000 would consist of: (1) Up to 340 TREK generating units installed in a matrix on the bottom of... underwater cables would convey each matrix power to a substation; and (4) a transmission line would...

  1. 76 FR 53445 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... installed in a matrix on the bottom of the river; (2) the total capacity of the installation would be up to 75,000 kilowatts; (3) shielded underwater cables would convey each matrix power to a substation; and...

  2. 76 FR 53439 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... consist of: (1) Up to 75 TREK generating units installed in a matrix on the bottom of the river; (2) the... convey each matrix power to a substation; and (4) a transmission line would interconnect with the power...

  3. 76 FR 53446 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... installed in a matrix on the bottom of the river; (2) the total capacity of the installation would be up to 35,000 kilowatts; (3) shielded underwater cables would convey each matrix power to a substation; and...

  4. 76 FR 53444 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... following: (1) Up to 240 TREK generating units installed in a matrix on the bottom of the river; (2) the... convey each matrix power to a substation; and (4) a transmission line would interconnect with the power...

  5. 76 FR 53432 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...: (1) Up to 1,053 TREK generating units installed in a matrix on the bottom of the river; (2) the total... each matrix power to a substation; and (4) a transmission line would interconnect with the power grid...

  6. 76 FR 53429 - Free Flow Power Corporation; Northland Power Mississippi River LLC; Notice of Competing...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ... consist of: (1) Up to 677 TREK generating units installed in a matrix on the bottom of the river; (2) the... would convey each matrix power to a substation; and (4) a transmission line would interconnect with the...

  7. 76 FR 53449 - Northland Power Mississippi River LLC; Notice of Preliminary Permit Application Accepted for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-26

    ...) Up to 320 TREK generating units installed in a matrix on the bottom of the river; (2) the total... each matrix's power to a substation; and (4) a transmission line would interconnect with the power grid. The proposed [[Page 53450

  8. Application of service oriented architecture for sensors and actuators in district heating substations.

    PubMed

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-08-21

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation.

  9. Application of Service Oriented Architecture for Sensors and Actuators in District Heating Substations

    PubMed Central

    Gustafsson, Jonas; Kyusakov, Rumen; Mäkitaavola, Henrik; Delsing, Jerker

    2014-01-01

    Hardwired sensor installations using proprietary protocols found in today's district heating substations limit the potential usability of the sensors in and around the substations. If sensor resources can be shared and re-used in a variety of applications, the cost of sensors and installation can be reduced, and their functionality and operability can be increased. In this paper, we present a new concept of district heating substation control and monitoring, where a service oriented architecture (SOA) is deployed in a wireless sensor network (WSN), which is integrated with the substation. IP-networking is exclusively used from sensor to server; hence, no middleware is needed for Internet integration. Further, by enabling thousands of sensors with SOA capabilities, a System of Systems approach can be applied. The results of this paper show that it is possible to utilize SOA solutions with heavily resource-constrained embedded devices in contexts where the real-time constrains are limited, such as in a district heating substation. PMID:25196165

  10. 20 CFR 631.31 - Monitoring and oversight.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... TITLE III OF THE JOB TRAINING PARTNERSHIP ACT State Administration § 631.31 Monitoring and oversight. The Governor is responsible for monitoring and oversight of all State and substate grantee activities... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Monitoring and oversight. 631.31 Section 631...

  11. 20 CFR 631.31 - Monitoring and oversight.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... TITLE III OF THE JOB TRAINING PARTNERSHIP ACT State Administration § 631.31 Monitoring and oversight. The Governor is responsible for monitoring and oversight of all State and substate grantee activities... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Monitoring and oversight. 631.31 Section 631...

  12. 20 CFR 631.31 - Monitoring and oversight.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... TITLE III OF THE JOB TRAINING PARTNERSHIP ACT State Administration § 631.31 Monitoring and oversight. The Governor is responsible for monitoring and oversight of all State and substate grantee activities... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Monitoring and oversight. 631.31 Section 631...

  13. Comparison of electric field exposure monitoring instrumentation. Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bracken, T.D.

    1985-06-01

    Electric field exposure monitoring instrumentation was compared and evaluated during three days of tests performed in 60-Hz electric fields. A conducting vest exposure meter and a small electric field exposure meter (EFEM) located in a shirt pocket, arm band or hard hat were compared in a series of static and dynamic tests. In some tests, the devices were worn simultaneously without interference to provide separate measures of identical exposure. Tests with stationary subjects wearing the instruments were used to measure the effects of grounding, and to establish the meter response in a standard posture for each subject. Dynamic occupational exposuremore » simulations were used to compare accumulated measurements of exposure between instruments and to compare measurements with predicted exposures. The simulations were based on analysis of the work-related behavior of substation electricians and operators. Electrician's tasks at ground level and in a bucket truck were simulated near an energized test line. A simulated substation inspection was performed in a 230 kV substation. The exposure measurements demonstrated an overall consistency between the meters. The vest demonstrated less intersubject variability and less detailed exposure characterization. Measurements with the shirt pocket EFEM were below those made with the vest and with the EFEM in other locations. Insulation provided by shoe soles appeared to be the largest factor in reducing measured exposures during the substation inspection below those predicted from the unperturbed field. Improvements in meter design and additional measurements are suggested. 11 refs., 20 figs., 28 tabs.« less

  14. A design of wireless sensor networks for a power quality monitoring system.

    PubMed

    Lim, Yujin; Kim, Hak-Man; Kang, Sanggil

    2010-01-01

    Power grids deal with the business of generation, transmission, and distribution of electric power. Recently, interest in power quality in electrical distribution systems has increased rapidly. In Korea, the communication network to deliver voltage, current, and temperature measurements gathered from pole transformers to remote monitoring centers employs cellular mobile technology. Due to high cost of the cellular mobile technology, power quality monitoring measurements are limited and data gathering intervals are large. This causes difficulties in providing the power quality monitoring service. To alleviate the problems, in this paper we present a communication infrastructure to provide low cost, reliable data delivery. The communication infrastructure consists of wired connections between substations and monitoring centers, and wireless connections between pole transformers and substations. For the wireless connection, we employ a wireless sensor network and design its corresponding data forwarding protocol to improve the quality of data delivery. For the design, we adopt a tree-based data forwarding protocol in order to customize the distribution pattern of the power quality information. We verify the performance of the proposed data forwarding protocol quantitatively using the NS-2 network simulator.

  15. Monitoring the metering performance of an electronic voltage transformer on-line based on cyber-physics correlation analysis

    NASA Astrophysics Data System (ADS)

    Zhang, Zhu; Li, Hongbin; Tang, Dengping; Hu, Chen; Jiao, Yang

    2017-10-01

    Metering performance is the key parameter of an electronic voltage transformer (EVT), and it requires high accuracy. The conventional off-line calibration method using a standard voltage transformer is not suitable for the key equipment in a smart substation, which needs on-line monitoring. In this article, we propose a method for monitoring the metering performance of an EVT on-line based on cyber-physics correlation analysis. By the electrical and physical properties of a substation running in three-phase symmetry, the principal component analysis method is used to separate the metering deviation caused by the primary fluctuation and the EVT anomaly. The characteristic statistics of the measured data during operation are extracted, and the metering performance of the EVT is evaluated by analyzing the change in statistics. The experimental results show that the method successfully monitors the metering deviation of a Class 0.2 EVT accurately. The method demonstrates the accurate evaluation of on-line monitoring of the metering performance on an EVT without a standard voltage transformer.

  16. Conformational equilibria of light-activated rhodopsin in nanodiscs

    PubMed Central

    Van Eps, Ned; Caro, Lydia N.; Morizumi, Takefumi; Kusnetzow, Ana Karin; Szczepek, Michal; Hofmann, Klaus Peter; Bayburt, Timothy H.; Sligar, Stephen G.; Ernst, Oliver P.; Hubbell, Wayne L.

    2017-01-01

    Conformational equilibria of G-protein–coupled receptors (GPCRs) are intimately involved in intracellular signaling. Here conformational substates of the GPCR rhodopsin are investigated in micelles of dodecyl maltoside (DDM) and in phospholipid nanodiscs by monitoring the spatial positions of transmembrane helices 6 and 7 at the cytoplasmic surface using site-directed spin labeling and double electron–electron resonance spectroscopy. The photoactivated receptor in DDM is dominated by one conformation with weak pH dependence. In nanodiscs, however, an ensemble of pH-dependent conformational substates is observed, even at pH 6.0 where the MIIbH+ form defined by proton uptake and optical spectroscopic methods is reported to be the sole species present in native disk membranes. In nanodiscs, the ensemble of substates in the photoactivated receptor spontaneously decays to that characteristic of the inactive state with a lifetime of ∼16 min at 20 °C. Importantly, transducin binding to the activated receptor selects a subset of the ensemble in which multiple substates are apparently retained. The results indicate that in a native-like lipid environment rhodopsin activation is not analogous to a simple binary switch between two defined conformations, but the activated receptor is in equilibrium between multiple conformers that in principle could recognize different binding partners. PMID:28373559

  17. A quantum leap into the IED age

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patterson, R.C.

    1996-11-01

    The integration of pattern recognition, artificial intelligence and advanced communication technologies in utility substation IED`s (Intelligent Electronic Devices) has opened the door to practical and cost effective automation of power distribution systems. A major driver for the application of these new technologies has been the research directed toward the detection of high-impedance faults. The commercial products which embody these complex detection functions have already expanded to include most of the protection, control, and monitoring required at a utility substation. These new Super-IED`s enable major utility initiatives, such as power quality management, improved public safety, operation and maintenance productivity, and powermore » system automation.« less

  18. A New Approach to Detection of Systematic Errors in Secondary Substation Monitoring Equipment Based on Short Term Load Forecasting

    PubMed Central

    Moriano, Javier; Rodríguez, Francisco Javier; Martín, Pedro; Jiménez, Jose Antonio; Vuksanovic, Branislav

    2016-01-01

    In recent years, Secondary Substations (SSs) are being provided with equipment that allows their full management. This is particularly useful not only for monitoring and planning purposes but also for detecting erroneous measurements, which could negatively affect the performance of the SS. On the other hand, load forecasting is extremely important since they help electricity companies to make crucial decisions regarding purchasing and generating electric power, load switching, and infrastructure development. In this regard, Short Term Load Forecasting (STLF) allows the electric power load to be predicted over an interval ranging from one hour to one week. However, important issues concerning error detection by employing STLF has not been specifically addressed until now. This paper proposes a novel STLF-based approach to the detection of gain and offset errors introduced by the measurement equipment. The implemented system has been tested against real power load data provided by electricity suppliers. Different gain and offset error levels are successfully detected. PMID:26771613

  19. Ground potential rise characteristics of urban step-down substations fed by power cables - A practical example

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sobral, S.T.; Barbosa, J.O.; Numes, J.V.C.

    1988-10-01

    This paper shows some special ground potential rise characteristics of substations fed by power cables. These characteristics were detected during the study of the interconnected ground system of 14 step-down urban substations fed by the 138 kV underground cable network serving the South Zone of Rio de Janeiro city in Brazil. As this type of system is very common in large cities, the subject can be of general interest for the industry. It was verified that when a fault occurs at a ''cable substation'' (a substation fed exclusively by power cables), almost no ground potential effects were detected at themore » faulted substation or at the other ''cable substations'' of the 138 kV network. However, high values of ground potential occurred at the ''transition substations'' (substations in which the power cables are connected to overhead 138 kV transmission lines, with steel groundwires). That ground potential was enough to produce shocks and equipment damage in certain ''transition substations''. It was verified that this problem has no relation with potential transfer. The paper shows also that the utilization of overhead lines with ACSR groundwires on the initial spans closer to the ''transition substation'' would be enough to avoid the problem. Even if the ACSR conductor is used only at the initial section of one of the lines, a reduction of the problem would be obtained. The paper shows also that the utilization of ACSR ground-wires near the ''transition substations'' contributes to reduce the amount of the copper necessary to control step, touch and mess potentials in these substations. Additional mitigation procedures are also examined in the paper.« less

  20. 77 FR 58828 - Northern Indiana Public Service Company; Notice of Petition for Declaratory Order

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-24

    ... kV transmission line from the Reynolds substation to the Greentown substation and (2) substation upgrades at Reynolds substation, including a 765 kV/345kV transformer, a Multi-Value Project approved under...

  1. 40 CFR 35.1615 - Substate agreements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 1 2014-07-01 2014-07-01 false Substate agreements. 35.1615 Section 35... STATE AND LOCAL ASSISTANCE Cooperative Agreements for Protecting and Restoring Publicly Owned Freshwater Lakes § 35.1615 Substate agreements. States may make financial assistance available to substate agencies...

  2. 40 CFR 35.1615 - Substate agreements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Substate agreements. 35.1615 Section 35... STATE AND LOCAL ASSISTANCE Cooperative Agreements for Protecting and Restoring Publicly Owned Freshwater Lakes § 35.1615 Substate agreements. States may make financial assistance available to substate agencies...

  3. View southeast of main supervisory board showing panels 3 through ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View southeast of main supervisory board showing panels 3 through 11; panel 3 at far left contains meters for monitoring power in the system; panel 4 contains controls for controlling heaters to keep track twitches free of ice and snow; panels 5, 6, and 7 date to the 1935 installation and control the catenary in the area of the station yard. These work on 120 volts direct current; panel 8 contains circuit breakers (rupture switches) which control power to individual tracks in the station area; panels 9 and 10 house controls for the West Philadelphia sub-station; panel 11 controls sub-station 13 in South Wilmington Delaware and miscellaneous meters - Thirtieth Street Station, Power Director Center, Thirtieth & Market Streets in Amtrak Railroad Station, Philadelphia, Philadelphia County, PA

  4. Fault Current Distribution and Pole Earth Potential Rise (EPR) Under Substation Fault

    NASA Astrophysics Data System (ADS)

    Nnassereddine, M.; Rizk, J.; Hellany, A.; Nagrial, M.

    2013-09-01

    New high-voltage (HV) substations are fed by transmission lines. The position of these lines necessitates earthing design to ensure safety compliance of the system. Conductive structures such as steel or concrete poles are widely used in HV transmission mains. The earth potential rise (EPR) generated by a fault at the substation could result in an unsafe condition. This article discusses EPR based on substation fault. The pole EPR assessment under substation fault is assessed with and without mutual impedance consideration. Split factor determination with and without the mutual impedance of the line is also discussed. Furthermore, a simplified formula to compute the pole grid current under substation fault is included. Also, it includes the introduction of the n factor which determines the number of poles that required earthing assessments under substation fault. A case study is shown.

  5. Using Immersive Virtual Reality for Electrical Substation Training

    ERIC Educational Resources Information Center

    Tanaka, Eduardo H.; Paludo, Juliana A.; Cordeiro, Carlúcio S.; Domingues, Leonardo R.; Gadbem, Edgar V.; Euflausino, Adriana

    2015-01-01

    Usually, distribution electricians are called upon to solve technical problems found in electrical substations. In this project, we apply problem-based learning to a training program for electricians, with the help of a virtual reality environment that simulates a real substation. Using this virtual substation, users may safely practice maneuvers…

  6. View west within the periphery of the load dispatch model ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View west within the periphery of the load dispatch model board, operator's console is at lower center and button board is at lower right of the photograph; section of model board shown covers substation from Perryman (left) to Frankford (right); instruments at right center of photograph formerly monitored energy usage and were replaced by computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA

  7. Study on Noise Prediction Model and Control Schemes for Substation

    PubMed Central

    Gao, Yang; Liu, Songtao

    2014-01-01

    With the government's emphasis on environmental issues of power transmission and transformation project, noise pollution has become a prominent problem now. The noise from the working transformer, reactor, and other electrical equipment in the substation will bring negative effect to the ambient environment. This paper focuses on using acoustic software for the simulation and calculation method to control substation noise. According to the characteristics of the substation noise and the techniques of noise reduction, a substation's acoustic field model was established with the SoundPLAN software to predict the scope of substation noise. On this basis, 4 reasonable noise control schemes were advanced to provide some helpful references for noise control during the new substation's design and construction process. And the feasibility and application effect of these control schemes can be verified by using the method of simulation modeling. The simulation results show that the substation always has the problem of excessive noise at boundary under the conventional measures. The excess noise can be efficiently reduced by taking the corresponding noise reduction methods. PMID:24672356

  8. Analysis of the monitoring data of geomagnetic storm interference in the electrification system of a high-speed railway

    NASA Astrophysics Data System (ADS)

    Liu, Lianguang; Ge, Xiaoning; Zong, Wei; Zhou, You; Liu, Mingguang

    2016-10-01

    To study the impact of geomagnetic storm on the equipment of traction electrification system in the high-speed railway, geomagnetically induced current (GIC) monitoring devices were installed in the Hebi East traction power supply substation of the Beijing-Hong Kong Dedicated Passenger Line in January 2015, and GICs were captured during the two geomagnetic storms on 17 March and 23 June 2015. In order to investigate the GIC flow path, both in the track circuit and in the traction network adopting the autotransformer feeding system, a GIC monitor plan was proposed for the electrical system in the Hebi East traction power supply substation. This paper analyzes the correlation between the GIC captured on 17 March and the geomagnetic data obtained from the Malingshan Geomagnetic Observatory and presents a regression analysis between the measured GIC and the calculated geoelectric fields on 23 June in the high-speed railway. The maximum GICs measured in the track circuit are 1.08 A and 1.74 A during the two geomagnetic storms. We find that it is necessary to pay attention on the throttle transformers and track circuits, as the most sensitive elements responding to the extreme geomagnetic storms in the high-speed railway.

  9. Discovering Conformational Sub-States Relevant to Protein Function

    PubMed Central

    Ramanathan, Arvind; Savol, Andrej J.; Langmead, Christopher J.; Agarwal, Pratul K.; Chennubhotla, Chakra S.

    2011-01-01

    Background Internal motions enable proteins to explore a range of conformations, even in the vicinity of native state. The role of conformational fluctuations in the designated function of a protein is widely debated. Emerging evidence suggests that sub-groups within the range of conformations (or sub-states) contain properties that may be functionally relevant. However, low populations in these sub-states and the transient nature of conformational transitions between these sub-states present significant challenges for their identification and characterization. Methods and Findings To overcome these challenges we have developed a new computational technique, quasi-anharmonic analysis (QAA). QAA utilizes higher-order statistics of protein motions to identify sub-states in the conformational landscape. Further, the focus on anharmonicity allows identification of conformational fluctuations that enable transitions between sub-states. QAA applied to equilibrium simulations of human ubiquitin and T4 lysozyme reveals functionally relevant sub-states and protein motions involved in molecular recognition. In combination with a reaction pathway sampling method, QAA characterizes conformational sub-states associated with cis/trans peptidyl-prolyl isomerization catalyzed by the enzyme cyclophilin A. In these three proteins, QAA allows identification of conformational sub-states, with critical structural and dynamical features relevant to protein function. Conclusions Overall, QAA provides a novel framework to intuitively understand the biophysical basis of conformational diversity and its relevance to protein function. PMID:21297978

  10. Research on the Wire Network Signal Prediction Based on the Improved NNARX Model

    NASA Astrophysics Data System (ADS)

    Zhang, Zipeng; Fan, Tao; Wang, Shuqing

    It is difficult to obtain accurately the wire net signal of power system's high voltage power transmission lines in the process of monitoring and repairing. In order to solve this problem, the signal measured in remote substation or laboratory is employed to make multipoint prediction to gain the needed data. But, the obtained power grid frequency signal is delay. In order to solve the problem, an improved NNARX network which can predict frequency signal based on multi-point data collected by remote substation PMU is describes in this paper. As the error curved surface of the NNARX network is more complicated, this paper uses L-M algorithm to train the network. The result of the simulation shows that the NNARX network has preferable predication performance which provides accurate real time data for field testing and maintenance.

  11. Deep learning based state recognition of substation switches

    NASA Astrophysics Data System (ADS)

    Wang, Jin

    2018-06-01

    Different from the traditional method which recognize the state of substation switches based on the running rules of electrical power system, this work proposes a novel convolutional neuron network-based state recognition approach of substation switches. Inspired by the theory of transfer learning, we first establish a convolutional neuron network model trained on the large-scale image set ILSVRC2012, then the restricted Boltzmann machine is employed to replace the full connected layer of the convolutional neuron network and trained on our small image dataset of 110kV substation switches to get a stronger model. Experiments conducted on our image dataset of 110kV substation switches show that, the proposed approach can be applicable to the substation to reduce the running cost and implement the real unattended operation.

  12. Project FOOTPRINT: Substation modeling and simulations for E1 pulses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelson, Scott D.; Larson, D. J.; Kirkendall, B. A.

    This report includes a presentation with an: Introduction to CW coupling; Introduction to single-pulse coupling; Description of E1 waveforms; Structures in a substation yard --articulated (as part of the substation's defined electrical functionality)--unarticulated (not as part of the substation's defined electrical functionality); Coupling --electrical coupling (capacitive coupling) --magnetic coupling (inductive coupling); Connectivity to long-line transmission lines; Control infrastructure; Summary; and References.

  13. View of EPA Farm power substation, facing westsouthwest Nevada ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View of EPA Farm power substation, facing west-southwest - Nevada Test Site, Environmental Protection Agency Farm, Power Substation, Area 15, Yucca Flat, 10-2 Road near Circle Road, Mercury, Nye County, NV

  14. Resilient Core Networks for Energy Distribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kuntze, Nicolai; Rudolph, Carsten; Leivesley, Sally

    2014-07-28

    Abstract—Substations and their control are crucial for the availability of electricity in today’s energy distribution. Ad- vanced energy grids with Distributed Energy Resources require higher complexity in substations, distributed functionality and communication between devices inside substations and between substations. Also, substations include more and more intelligent devices and ICT based systems. All these devices are connected to other systems by different types of communication links or are situated in uncontrolled environments. Therefore, the risk of ICT based attacks on energy grids is growing. Consequently, security measures to counter these risks need to be an intrinsic part of energy grids. Thismore » paper introduces the concept of a Resilient Core Network to interconnected substations. This core network provides essen- tial security features, enables fast detection of attacks and allows for a distributed and autonomous mitigation of ICT based risks.« less

  15. The importance of substate surveillance in detection of geographic oral health inequalities in a small state.

    PubMed

    Anderson, Ludmila; Martin, Nancy R; Flynn, Regina T; Knight, Susan

    2012-01-01

    Considering that 42% of children and adolescents and 91% of dentate adults experience dental caries, oral disease is a public health problem. Although the population's oral health is improving, certain subgroups remain at increased risk for dental disease. To assess the oral health status at the substate level and explore the possibility of geographic oral health inequalities in New Hampshire while building upon existing surveillance data sets. We used the Third Grade Oral Health and NH Behavioral Risk Factor Surveillance System surveys. We ensured the availability of substate level data and compared county/region specific estimates. New Hampshire. Adults and third-grade students in public schools. The prevalence of dental caries, untreated caries, and dental sealants among children; and the insurance status, utilization of dental services, and edentulism among adults. Of the 10 counties, the northernmost Coos County had consistently worse outcomes when compared with other counties. Only 64% of adult Coos County residents reported a dental visit in the past year; of these, 66% reported dental cleaning. Among adults 65 years and older, 29% were edentulous. In comparison with the state overall, these estimates were 76%, 77%, and 19%, respectively. Coos County third-grade students had the highest prevalence of dental caries experience (64% compared with 44% in New Hampshire) and untreated caries (31% compared with 12%), and only 24% had dental sealants (state prevalence is 60%). Overall oral health status in our state is favorable and comparable with the nation, yet significant geographic inequalities exist among children and adults. The oral health status of disparate groups can be improved using tailored interventions such as community water fluoridation or expansion of school-based dental sealant programs. Surveillance at the substate level is an essential part of the planning, targeting, and progress monitoring.

  16. Workers' exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations.

    PubMed

    Korpinen, Leena; Pääkkönen, Rauno

    2018-02-26

    The objective of the study was to investigate occupational exposure to electric fields during the task 'maintenance of an operating device of circuit breaker from a service platform' at 110-kV substations. The aim was also to compare the results to Directive 2013/35/EU. At 16 substations, 255 electric field measurements were performed. The highest mean value of the electric fields was 9.6 kV⋅m -1 . At 63% of substations the maximum values were over 10.0 kV⋅m -1 , and at 31% of the substations the 75th percentiles were over 10.0 kV⋅m -1 , which is the low action level (AL) according to Directive 2013/35/EU. All measured values were below the high AL (20.0 kV⋅m -1 ). In the future, it is important to take into account that the measurements were only taken at Finnish 110-kV substations; therefore, it is not possible to generalize these results to other countries and different types of substations.

  17. 76 FR 10582 - Town of Edgartown; Notice of Public/Technical Meeting To Discuss Information and Monitoring Needs...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-25

    ... Application for a Pilot Project a. Type of Application: Draft Pilot License Application. b. Project No.: 13015... either a 3.5-mile-long, or a 5- mile-long submarine cable with two 13.8-kilovolt (kv) transmission lines and a 4.0-kv transmission line connecting the turbine generation units to an onshore substation...

  18. AUTOMATED UTILITY SERVICE AREA ASSESSMENT UNDER EMERGENCY CONDITIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    G. TOOLE; S. LINGER

    2001-01-01

    All electric utilities serve power to their customers through a variety of functional levels, notably substations. The majority of these components consist of distribution substations operating at lower voltages while a small fraction are transmission substations. There is an associated geographical area that encompasses customers who are served, defined as the service area. Analysis of substation service areas is greatly complicated by several factors: distribution networks are often highly interconnected which allows a multitude of possible switching operations; also, utilities dynamically alter the network topology in order to respond to emergency events. As a result, the service area for amore » substation can change radically. A utility will generally attempt to minimize the number of customers outaged by switching effected loads to alternate substations. In this manner, all or a portion of a disabled substation's load may be served by one or more adjacent substations. This paper describes a suite of analytical tools developed at Los Alamos National Laboratory (LANL), which address the problem of determining how a utility might respond to such emergency events. The estimated outage areas derived using the tools are overlaid onto other geographical and electrical layers in a geographic information system (GIS) software application. The effects of a power outage on a population, other infrastructures, or other physical features, can be inferred by the proximity of these features to the estimated outage area.« less

  19. Structural assessment of highway "N" power substation under earthquake loads.

    DOT National Transportation Integrated Search

    2009-10-01

    In this study, the Highway N Substation was analyzed with a finite element model (FEM) for its vulnerability. The rigid bus and electric switch components were characterized with full scale shake table tests. Each component of the substation wa...

  20. Substation Reactive Power Regulation Strategy

    NASA Astrophysics Data System (ADS)

    Zhang, Junfeng; Zhang, Chunwang; Ma, Daqing

    2018-01-01

    With the increasing requirements on the power supply quality and reliability of distribution network, voltage and reactive power regulation of substations has become one of the indispensable ways to ensure voltage quality and reactive power balance and to improve the economy and reliability of distribution network. Therefore, it is a general concern of the current power workers and operators that what kind of flexible and effective control method should be used to adjust the on-load tap-changer (OLTC) transformer and shunt compensation capacitor in a substation to achieve reactive power balance in situ, improve voltage pass rate, increase power factor and reduce active power loss. In this paper, based on the traditional nine-zone diagram and combining with the characteristics of substation, a fuzzy variable-center nine-zone diagram control method is proposed and used to make a comprehensive regulation of substation voltage and reactive power. Through the calculation and simulation of the example, this method is proved to have satisfactorily reconciled the contradiction between reactive power and voltage in real-time control and achieved the basic goal of real-time control of the substation, providing a reference value to the practical application of the substation real-time control method.

  1. 17. Photocopy of photograph showing excavation of South Bank Substation ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    17. Photocopy of photograph showing excavation of South Bank Substation site, 15 May 1939 (from the BPA Photo Archives, Portland, Oregon, Negative No. 345), LOOKING WEST - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  2. 20 CFR 631.82 - Substate allocation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Substate allocation. 631.82 Section 631.82 Employees' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS UNDER TITLE III OF THE JOB TRAINING PARTNERSHIP ACT Disaster Relief Employment Assistance § 631.82 Substate allocation...

  3. An application of data mining in district heating substations for improving energy performance

    NASA Astrophysics Data System (ADS)

    Xue, Puning; Zhou, Zhigang; Chen, Xin; Liu, Jing

    2017-11-01

    Automatic meter reading system is capable of collecting and storing a huge number of district heating (DH) data. However, the data obtained are rarely fully utilized. Data mining is a promising technology to discover potential interesting knowledge from vast data. This paper applies data mining methods to analyse the massive data for improving energy performance of DH substation. The technical approach contains three steps: data selection, cluster analysis and association rule mining (ARM). Two-heating-season data of a substation are used for case study. Cluster analysis identifies six distinct heating patterns based on the primary heat of the substation. ARM reveals that secondary pressure difference and secondary flow rate have a strong correlation. Using the discovered rules, a fault occurring in remote flow meter installed at secondary network is detected accurately. The application demonstrates that data mining techniques can effectively extrapolate potential useful knowledge to better understand substation operation strategies and improve substation energy performance.

  4. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  5. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  6. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  7. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  8. 30 CFR 77.811 - Movement of portable substations and transformers.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Movement of portable substations and transformers. 77.811 Section 77.811 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF... and transformers. Portable substations and transformers shall be deenergized before they are moved...

  9. Research on Vibration Test in Urban Indoor Substation

    NASA Astrophysics Data System (ADS)

    Ma, Yuchao; Mo, Juan; Xu, Jin; Fan, Baozhen

    2018-01-01

    The problem of vibration and noise of urban indoor substations has becoming more and more socially concerned.The urban indoor substation of 110kV and its conjoined buildings were taken as the research object and the vibration tests of the transformer and each floor slab were respectively carried out.The sound vibration characteristics and sound transmission rules of the urban indoor substation were obtained through the time-frequency analysis and coherence analysis of the test data. The vibration spectrum of transformer body was mainly 100Hz together with its multiplying factors and the vibration characteristics of the floor slab were basically the same as those of the transformer body. it is crucial to control the vibration and noise transmission in the equipment floor of the urban indoor substation.

  10. Protein Conformational Populations and Functionally Relevant Sub-states

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, Pratul K; Burger, Virginia; Savol, Andrej

    2013-01-01

    Functioning proteins do not remain fixed in a unique structure, but instead they sample a range of conformations facilitated by motions within the protein. Even in the native state, a protein exists as a collection of interconverting conformations driven by thermodynamic fluctuations. Motions on the fast time scale allow a protein to sample conformations in the nearby area of its conformational landscape, while motions on slower time scales give it access to conformations in distal areas of the landscape. Emerging evidence indicates that protein landscapes contain conformational substates with dynamic and structural features that support the designated function of themore » protein. Nuclear magnetic resonance (NMR) experiments provide information about conformational ensembles of proteins. X-ray crystallography allows researchers to identify the most populated states along the landscape, and computational simulations give atom-level information about the conformational substates of different proteins. This ability to characterize and obtain quantitative information about the conformational substates and the populations of proteins within them is allowing researchers to better understand the relationship between protein structure and dynamics and the mechanisms of protein function. In this Account, we discuss recent developments and challenges in the characterization of functionally relevant conformational populations and substates of proteins. In some enzymes, the sampling of functionally relevant conformational substates is connected to promoting the overall mechanism of catalysis. For example, the conformational landscape of the enzyme dihydrofolate reductase has multiple substates, which facilitate the binding and the release of the cofactor and substrate and catalyze the hydride transfer. For the enzyme cyclophilin A, computational simulations reveal that the long time scale conformational fluctuations enable the enzyme to access conformational substates that allow it to attain the transition state, therefore promoting the reaction mechanism. In the long term, this emerging view of proteins with conformational substates has broad implications for improving our understanding of enzymes, enzyme engineering, and better drug design. Researchers have already used photoactivation to modulate protein conformations as a strategy to develop a hypercatalytic enzyme. In addition, the alteration of the conformational substates through binding of ligands at locations other than the active site provides the basis for the design of new medicines through allosteric modulation.« less

  11. 20. Photocopy of photograph showing the completed South Bank Substation, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Photocopy of photograph showing the completed South Bank Substation, 4 November 1939 (from the BPA Photo Archives, Negative No. 6556), LOOKING NORTHWEST WITH THE BONNEVILLE DAM POWERHOUSE AND TRANSMISSION TOWERS IN BACKGROUND - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  12. Research on the Best Root Span of 500kV Substation Frame Based on Finite Element

    NASA Astrophysics Data System (ADS)

    Chen, Hao; Fang, Qing; Chen, Haoyuan

    2018-01-01

    A-shaped and steel tube structures have been widely applied when designing 500kV substation frame in China. While, compared with steel tube, angle steels have an advantage of easy-transporting, especially in oversea projects. However, researches on substation frame with angle steel were not enough. In order to find out the best root span of 500kV substation frame under similar engineering conditions, using the overseas project substation frame as an example, the substation frames with different root span have been detailed calculated, to find the best root span according to the cost of it. When the height of column is about 30m, the root suggestion value is 6.1m×3.1m. And then, the buckling analysis of the overall structure has been carried out by ANSYS, to find out that the weak part of the structure is in the middle of it. The structural adjustment is carried out for the weak part, including adjusting the web members and the chord members, to obtain a higher bearing capacity of the structure.

  13. Hydrology Analysis and Modelling for Klang River Basin Flood Hazard Map

    NASA Astrophysics Data System (ADS)

    Sidek, L. M.; Rostam, N. E.; Hidayah, B.; Roseli, ZA; Majid, W. H. A. W. A.; Zahari, N. Z.; Salleh, S. H. M.; Ahmad, R. D. R.; Ahmad, M. N.

    2016-03-01

    Flooding, a common environmental hazard worldwide has in recent times, increased as a result of climate change and urbanization with the effects felt more in developing countries. As a result, the explosive of flooding to Tenaga Nasional Berhad (TNB) substation is increased rapidly due to existing substations are located in flood prone area. By understanding the impact of flood to their substation, TNB has provided the non-structure mitigation with the integration of Flood Hazard Map with their substation. Hydrology analysis is the important part in providing runoff as the input for the hydraulic part.

  14. Space and energy. [space systems for energy generation, distribution and control

    NASA Technical Reports Server (NTRS)

    Bekey, I.

    1976-01-01

    Potential contributions of space to energy-related activities are discussed. Advanced concepts presented include worldwide energy distribution to substation-sized users using low-altitude space reflectors; powering large numbers of large aircraft worldwide using laser beams reflected from space mirror complexes; providing night illumination via sunlight-reflecting space mirrors; fine-scale power programming and monitoring in transmission networks by monitoring millions of network points from space; prevention of undetected hijacking of nuclear reactor fuels by space tracking of signals from tagging transmitters on all such materials; and disposal of nuclear power plant radioactive wastes in space.

  15. 76 FR 45609 - Notice of Availability of the Draft Environmental Impact Statement for the Gateway West 230/500...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... Johnston Power Plant at Glenrock, Wyoming, to the proposed Hemingway Substation near Melba, Idaho. The... Johnston Power Plant at Glenrock, Wyoming, and the planned Aeolus Substation near Hanna, Wyoming. Segment... Anticline Substation near the Jim Bridger Power Plant, located approximately 30 miles east of Rock Springs...

  16. Conformational switching between protein substates studied with 2D IR vibrational echo spectroscopy and molecular dynamics simulations.

    PubMed

    Bagchi, Sayan; Thorpe, Dayton G; Thorpe, Ian F; Voth, Gregory A; Fayer, M D

    2010-12-30

    Myoglobin is an important protein for the study of structure and dynamics. Three conformational substates have been identified for the carbonmonoxy form of myoglobin (MbCO). These are manifested as distinct peaks in the IR absorption spectrum of the CO stretching mode. Ultrafast 2D IR vibrational echo chemical exchange experiments are used to observed switching between two of these substates, A(1) and A(3), on a time scale of <100 ps for two mutants of wild-type Mb. The two mutants are a single mutation of Mb, L29I, and a double mutation, T67R/S92D. Molecular dynamics (MD) simulations are used to model the structural differences between the substates of the two MbCO mutants. The MD simulations are also employed to examine the substate switching in the two mutants as a test of the ability of MD simulations to predict protein dynamics correctly for a system in which there is a well-defined transition over a significant potential barrier between two substates. For one mutant, L29I, the simulations show that translation of the His64 backbone may differentiate the two substates. The simulations accurately reproduce the experimentally observed interconversion time for the L29I mutant. However, MD simulations exploring the same His64 backbone coordinate fail to display substate interconversion for the other mutant, T67R/S92D, thus pointing to the likely complexity of the underlying protein interactions. We anticipate that understanding conformational dynamics in MbCO via ultrafast 2D IR vibrational echo chemical exchange experiments can help to elucidate fast conformational switching processes in other proteins.

  17. Direct observation of fast protein conformational switching.

    PubMed

    Ishikawa, Haruto; Kwak, Kyungwon; Chung, Jean K; Kim, Seongheun; Fayer, Michael D

    2008-06-24

    Folded proteins can exist in multiple conformational substates. Each substate reflects a local minimum on the free-energy landscape with a distinct structure. By using ultrafast 2D-IR vibrational echo chemical-exchange spectroscopy, conformational switching between two well defined substates of a myoglobin mutant is observed on the approximately 50-ps time scale. The conformational dynamics are directly measured through the growth of cross peaks in the 2D-IR spectra of CO bound to the heme active site. The conformational switching involves motion of the distal histidine/E helix that changes the location of the imidazole side group of the histidine. The exchange between substates changes the frequency of the CO, which is detected by the time dependence of the 2D-IR vibrational echo spectrum. These results demonstrate that interconversion between protein conformational substates can occur on very fast time scales. The implications for larger structural changes that occur on much longer time scales are discussed.

  18. Wireless Sensor Network for Radiometric Detection and Assessment of Partial Discharge in High-Voltage Equipment

    NASA Astrophysics Data System (ADS)

    Upton, D. W.; Saeed, B. I.; Mather, P. J.; Lazaridis, P. I.; Vieira, M. F. Q.; Atkinson, R. C.; Tachtatzis, C.; Garcia, M. S.; Judd, M. D.; Glover, I. A.

    2018-03-01

    Monitoring of partial discharge (PD) activity within high-voltage electrical environments is increasingly used for the assessment of insulation condition. Traditional measurement techniques employ technologies that either require off-line installation or have high power consumption and are hence costly. A wireless sensor network is proposed that utilizes only received signal strength to locate areas of PD activity within a high-voltage electricity substation. The network comprises low-power and low-cost radiometric sensor nodes which receive the radiation propagated from a source of PD. Results are reported from several empirical tests performed within a large indoor environment and a substation environment using a network of nine sensor nodes. A portable PD source emulator was placed at multiple locations within the network. Signal strength measured by the nodes is reported via WirelessHART to a data collection hub where it is processed using a location algorithm. The results obtained place the measured location within 2 m of the actual source location.

  19. Analysis of the 35 KV substation secondary system

    NASA Astrophysics Data System (ADS)

    Zhao, Yong; Jiang, Jianguo; Jiang, Chunlei; Ren, Shuang; Liu, Songbin

    2017-04-01

    This paper analyzes the status of the two system of some 35KV users' substation in Daqing oil field, the deficiencies of the two system of the existing 35KV substation are found out. And put forward the opinion of acceptance in the future work. I hope it can able to work in the future on the protection of professional help.

  20. Shielding of substations against direct lightning strokes by shield wires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chowdhuri, P.

    1994-01-01

    A new analysis for shielding outdoor substations against direct lightning strokes by shield wires is proposed. The basic assumption of this proposed method is that any lightning stroke which penetrates the shields will cause damage. The second assumption is that a certain level of risk of failure must be accepted, such as one or two failures per 100 years. The proposed method, using electrogeometric model, was applied to design shield wires for two outdoor substations: (1) 161-kV/69-kV station, and (2) 500-kV/161-kV station. The results of the proposed method were also compared with the shielding data of two other substations.

  1. Power system distributed oscilation detection based on Synchrophasor data

    NASA Astrophysics Data System (ADS)

    Ning, Jiawei

    Along with increasing demand for electricity, integration of renewable energy and deregulation of power market, power industry is facing unprecedented challenges nowadays. Within the last couple of decades, several serious blackouts have been taking place in United States. As an effective approach to prevent that, power system small signal stability monitoring has been drawing more interests and attentions from researchers. With wide-spread implementation of Synchrophasors around the world in the last decade, power systems real-time online monitoring becomes much more feasible. Comparing with planning study analysis, real-time online monitoring would benefit control room operators immediately and directly. Among all online monitoring methods, Oscillation Modal Analysis (OMA), a modal identification method based on routine measurement data where the input is unmeasured ambient excitation, is a great tool to evaluate and monitor power system small signal stability. Indeed, high sampling Synchrophasor data around power system is fitted perfectly as inputs to OMA. Existing methods in OMA for power systems are all based on centralized algorithms applying at control centers only; however, with rapid growing number of online Synchrophasors the computation burden at control centers is and will be continually exponentially expanded. The increasing computation time at control center compromises the real-time feature of online monitoring. The communication efforts between substation and control center will also be out of reach. Meanwhile, it is difficult or even impossible for centralized algorithms to detect some poorly damped local modes. In order to avert previous shortcomings of centralized OMA methods and embrace the new changes in the power systems, two new distributed oscillation detection methods with two new decentralized structures are presented in this dissertation. Since the new schemes brought substations into the big oscillation detection picture, the proposed methods could achieve faster and more reliable results. Subsequently, this claim is tested and approved by test results of IEEE Two-area simulation test system and real power system historian synchrophasor data case studies.

  2. A multi-agent approach to intelligent monitoring in smart grids

    NASA Astrophysics Data System (ADS)

    Vallejo, D.; Albusac, J.; Glez-Morcillo, C.; Castro-Schez, J. J.; Jiménez, L.

    2014-04-01

    In this paper, we propose a scalable multi-agent architecture to give support to smart grids, paying special attention to the intelligent monitoring of distribution substations. The data gathered by multiple sensors are used by software agents that are responsible for monitoring different aspects or events of interest, such as normal voltage values or unbalanced intensity values that can end up blowing fuses and decreasing the quality of service of end consumers. The knowledge bases of these agents have been built by means of a formal model for normality analysis that has been successfully used in other surveillance domains. The architecture facilitates the integration of new agents and can be easily configured and deployed to monitor different environments. The experiments have been conducted over a power distribution network.

  3. Pressure Studies of Protein Dynamics

    DTIC Science & Technology

    1990-02-28

    a frozen and metastable complex system In the present section was generated by a flashlamp-pumped dye laser (Phase-R DL- treat the equilibrium region...determination of the relative thermodynamic parameters of the and the temperature was monitored with a Si diode on the pressure We assume that the A substates...temperature controller (Model proteins is essentially linear from 200 to 320 K. 2" The entropy 93C). A silicon diode mounted on the sample cell

  4. IET. Exclusion guard house (TAN621) and unit substation (TAN622). Elevations ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    IET. Exclusion guard house (TAN-621) and unit substation (TAN-622). Elevations and floor plan. Also show concrete pad for substation. Ralph M. Parsons 902-4-ANP-621-622-A&S 411. Date: February 1954. Approved by INEEL Classification Office for public release. INEEL index code no. 035-0621-60-693-106968 - Idaho National Engineering Laboratory, Test Area North, Scoville, Butte County, ID

  5. Simulation study on the lightning overvoltage invasion control transformer intelligent substation

    NASA Astrophysics Data System (ADS)

    Xi, Chuyan; Hao, Jie; Zhang, Ying

    2018-04-01

    By simulating lightning on substation line of one intelligent substation, research the influence of different lightning points on lightning invasion wave overvoltage, and the necessity of arrester for the main transformer. The results show, in a certain lightning protection measures, the installation of arrester nearby the main transformer can effectively reduce the overvoltage value of bus and the main transformer [1].

  6. An expansion plan for the 60 Hz power distribution system at KSC: LC-39 substations load allocation plan

    NASA Technical Reports Server (NTRS)

    Kalu, Alex

    1990-01-01

    The increasing load density in the LC-39 area of Kennedy Space Center (KSC) can be met by either modifying the existing substation and increasing its capacity or by planning an additional new substation. Evidence that the later approach is more economical, enhances the system reliability, and would produce more satisfactory performance indices is provided. Network theory is the basis for the optimal location determination of the proposed substation. A load reallocation plan which minimizes investment cost and power losses and meets other desirable system features is drafted. The report should be useful to the system designer and can be a useful guideline for future facility planners.

  7. Experimental adoption of RCM in EDF substations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Heroin, G.; Aupied, J.; Sanchis, G.

    1996-08-01

    EDF, after testing Reliability Centered Maintenance (RCM) on systems used in nuclear power plants, has now successfully extended RCM to all of its nuclear power plants. In the light of this experience, EDF has committed itself to a pilot study on a line bay of a 400 kV substation in 1992. The RCM method as applied benefited from EDF`s policy of maintenance, introduced five years ago on all substations, which has enhanced prospects of reliability. The original feature in the selection of maintenance tasks was that it brought into play two criteria for failure assessment - frequency and seriousness -more » and two criteria for maintenance task selection - efficiency and facility. The final outcome of RCM as applied to substation maintenance is to categorize maintenance tasks into: (1) essential maintenance tasks, (2) optional tasks, depending on the type and location of the substation, as well as on factors relating to local management of maintenance policy, and (3) unnecessary tasks.« less

  8. CENet: A Cabinet Environmental Sensing Network

    PubMed Central

    Zhang, Zusheng; Yu, Fengqi; Chen, Liang; Cao, Guangmin

    2010-01-01

    For data center cooling and intelligent substation systems, real time cabinet environmental monitoring is a strong requirement. Monitoring data, such as temperature, humidity, and noise, is important for operators to manage the facilities in cabinets. We here propose a sensing network, called CENet, which is energy efficient and reliable for cabinet environmental monitoring. CENet achieves above 93% reliable data yield and sends fewer beacons compared to periodic beaconing. It does so through a data-aided routing protocol. In addition, based on B-MAC, we propose a scheduling scheme to increase the lifetime of the network by reducing unnecessary message snooping and channel listening, thus it is more energy efficient than B-MAC. The performance of CENet is evaluated by simulations and experiments. PMID:22205856

  9. Conformational Sub-states and Populations in Enzyme Catalysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Agarwal, Pratul K; Doucet, Nicholas; Chennubholta, C

    reactants in the active site, chemical turnover, and release of products. In addition to formation of crucial structural interactions between enzyme and substrate(s), coordinated motions within the enzyme substrate complex allow reaction to proceed at a much faster rate, compared to the reaction in solution and in the absence of enzyme. An increasing number of enzyme systems show the presence of conserved protein motions that are important for function. A wide variety of motions are naturally sampled (over femtosecond to millisecond time-scales) as the enzyme complex moves along the energetic landscape, driven by temperature and dynamical events from the surroundingmore » environment. Areas of low energy along the landscape form conformational sub-states, which show higher conformational populations than surrounding areas. A small number of these protein conformational sub-states contain functionally important structural and dynamical features, which assist the enzyme mechanism along the catalytic cycle. Identification and characterization of these higher-energy (also called excited) sub-states and the associated populations are challenging, as these sub-states are very short-lived and therefore rarely populated. Specialized techniques based on computer simulations, theoretical modeling, and nuclear magnetic resonance have been developed for quantitative characterization of these sub-states and populations. This chapter discusses these techniques and provides examples of their applications to enzyme systems.« less

  10. [Offshore substation workers' exposure to harmful factors - Actions minimizing risk of hazards].

    PubMed

    Piotrowski, Paweł Janusz; Robak, Sylwester; Polewaczyk, Mateusz Maksymilian; Raczkowski, Robert

    2016-01-01

    The current development of electric power industry in Poland, especially in the field of renewable energy sources, including wind power, brings about the need to introduce legislation on new work environment. The development of occupational safety and health (OSH) regulations that must be met by new workplaces, such as offshore substations becomes necessary in view of the construction of modern offshore wind power plants - offshore wind farms. Staying on offshore substation is associated with an increased exposure to harmful health factors: physical, chemical, biological and psychophysical. The main sources of health risks on offshore substations are: temperature, electromagnetic field, noise from operating wind turbines, direct and alternating current, chemicals, Legionella bacteria and social isolation of people. The aim of this article is to draw attention to the problem of offshore substation workers' exposure to harmful factors and to present methods of preventing and reducing the risk-related adverse health effects. In this paper, there are identified and described risks occurring on offshore substations (fire, explosion, lightning, accidents at work). Some examples of the means and the methods for reducing the negative impact of exposure on the human health are presented and discussed. The article also highlights the need to develop appropriate laws and health and safety regulations concerning the new working environment at the offshore substations. The review of researches and international standards shows that some of them can be introduced into the Polish labor market. This work is available in Open Access model and licensed under a CC BY-NC 3.0 PL license.

  11. Touch and step potential analysis at 23.9kV to 4.16kV & 13.8kV to 4.16kV distribution substations with pad-mounted transformers, floating grounds, and other exposed ungrounded metal bodies using WinIGS

    NASA Astrophysics Data System (ADS)

    Guzman, David G.

    An electrical substation is composed of various subsystems that allow for the effective and safe operation of the power grid. One of the subsystems integrating a conventional substation is defined as the ground grid system. This system allows for the effective operation of the power grid and all the electrical equipment connected to it by providing a ground potential reference, commonly known as the system ground. In addition, the ground grid system provides safety to the workers and the public transiting inside or living nearby a substation by reducing the step and touch potential (or voltage) levels present during a system fault. In today's utility industry practices there is an increasing trend for using pad-mounted electrical equipment for substation applications in an effort to construct new or upgrade existing electrical facilities inside limited property spaces. This thesis work presents an analysis for the effects of touch and step voltages at existing distribution substations where 23.9kV to 4.16kV & 13.8kV to 4.16kV pad-mounted transformers and other pad-mounted switchgear was installed to replace the traditional station class equipment. Moreover, this study will expose modeling techniques employed to define and determine the effects of floating grounds and other exposed metal bodies inside or surrounding these substations using WinIGS; this is in an effort to determine any risks of electric shock associated with this type of installations. The results presented in this work are intended to verify the requirements for the ground grid analysis and design for 4.16kV distribution substations with pad-mounted equipment in order to prevent dangerous step and touch voltage levels appearing at these sites during system faults; and ultimately prevent exposing individuals to the risk of an electric shock.

  12. Research on EME of real-time monitoring system

    NASA Astrophysics Data System (ADS)

    Meng, Ke; Guo, Jiang; Chai, Wei; Wu, Hongyan

    2018-01-01

    With the increase of the number of substations, the precision of electromagnetic environment parameters is higher. At present, there are many defects in the electromagnetic environment measuring system, such as the nonstandard data and the difficult reutilization. And many circuits with self-scale are controlled by switch, it has a great impact on the switching time and the service life of the device. A method of magnetic field range smooth switching is provided in this paper which is based on the magneto resistivity and the control of MCU, applying this method to the monitoring system which has functions of distributed data, real time data display, data storage and unified management etc.

  13. Design of a laser navigation system for the inspection robot used in substation

    NASA Astrophysics Data System (ADS)

    Zhu, Jing; Sun, Yanhe; Sun, Deli

    2017-01-01

    Aimed at the deficiency of the magnetic guide and RFID parking system used by substation inspection robot now, a laser navigation system is designed, and the system structure, the method of map building and positioning are all introduced. The system performance is tested in a 500kV substation, and the result show that the repetitive precision of navigation system is precise enough to help the robot fulfill inspection tasks.

  14. An improved method for predicting the lightning performance of high and extra-high-voltage substation shielding

    NASA Astrophysics Data System (ADS)

    Vinh, T.

    1980-08-01

    There is a need for better and more effective lightning protection for transmission and switching substations. In the past, a number of empirical methods were utilized to design systems to protect substations and transmission lines from direct lightning strokes. The need exists for convenient analytical lightning models adequate for engineering usage. In this study, analytical lightning models were developed along with a method for improved analysis of the physical properties of lightning through their use. This method of analysis is based upon the most recent statistical field data. The result is an improved method for predicting the occurrence of sheilding failure and for designing more effective protection for high and extra high voltage substations from direct strokes.

  15. Characteristic Analysis of DC Electric Railway Systems with Superconducting Power Cables Connecting Power Substations

    NASA Astrophysics Data System (ADS)

    Ohsaki, H.; Matsushita, N.; Koseki, T.; Tomita, M.

    2014-05-01

    The application of superconducting power cables to DC electric railway systems has been studied. It could leads to an effective use of regenerative brake, improved energy efficiency, effective load sharing among the substations, etc. In this study, an electric circuit model of a DC feeding system is built and numerical simulation is carried out using MATLAB-Simulink software. A modified electric circuit model with an AC power grid connection taken into account is also created to simulate the influence of the grid connection. The analyses have proved that a certain amount of energy can be conserved by introducing superconducting cables, and that electric load distribution and concentration among the substations depend on the substation output voltage distribution.

  16. Utility interconnection experience with an operating central station MW-sized photovoltaic plant

    NASA Astrophysics Data System (ADS)

    Patapoff, N. W., Jr.; Mattijetz, D. R.

    1985-08-01

    Utility experience to date with photovoltaic systems has been with small dispersed systems designed primarily as demonstration projects. The 1 MW photovoltaic plant at Lugo Substation in Hesperia, California, has been designed and is operated as a central station power plant. The performance of the system has been monitored since first coming on line in November 1982. The potential impact of this and similar systems upon the operation of the utility is discussed.

  17. The Millimeter- and Submillimeter-Wave Spectrum of Gauche-Ethyl Alcohol

    NASA Technical Reports Server (NTRS)

    Pearson, J. C.; Sastry, K. V. L. N.; Herbst, Eric; DeLucia, Frank C.

    1996-01-01

    We report an investigation of the rotational-torsional spectrum of the gauche rotational isomers of ethyl alcohol in the 51-505 GHz frequency region. Over a thousand transitions between rotational levels in the gauche substates of the ground OH torsional state have been measured and assigned. These transitions involve rotational quantum numbers J and K(sub a) up to 30 and 15, respectively, and are of two types: alpha-type transitions between levels in either the gauche+ or the gauche-substate, and c-type transitions between rotational levels in the different substates. The majority of these transitions have been fit satisfactorily using a two-state Hamiltonian based on the Fixed Framework Axis Method (FFAM). The rotation, distortion, and interaction constants have been determined along with the energy difference between the two gauche substates. The derived constants can be used to predict many more transitions accurately for astronomical purposes. The J and K(sub a) region where the two-state analysis can be used has been determined. The basis for a three-state analysis including the trans substate is presented and the applicability of the FFAM approach is discussed.

  18. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.957 Construction in energized substations. (a) Work near energized equipment facilities. (1...

  19. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.957 Construction in energized substations. (a) Work near energized equipment facilities. (1...

  20. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.957 Construction in energized substations. (a) Work near energized equipment facilities. (1...

  1. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-101) Spokane Region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosales, Michael A.

    2002-09-13

    Vegetation Management for Substations and Non-Electric Facilities. BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substation shall include the bare ground management of all graveled areas. These areas shall primarily be maintained with the use of herbicides. The management of vegetation outside the substation and associated facilities shall include: 1) bare ground management of perimeter roads and parking areas; 2) mechanical and/or spot herbicidal control of some broadleaves and noxious weeds; 3) mowing, fertilizing, and broadleaf control of landscaped lawn areas; 4) weed control in ornamental shrub areas; and 5) areasmore » requiring only mechanical control to manage unwanted/danger trees, grasses, and shrubs.« less

  2. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-64)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hutchinson, Ken

    2002-04-26

    Vegetation Management for Substations and Non-Electric Facilities in the Walla Walla Region. BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substation shall include the bare ground management of all graveled areas. These areas shall primarily be maintained with the use of herbicides. The management of vegetation outside the substation and associated facilities shall include: 1) bare ground management of perimeter roads and parking areas; 2) mechanical and/or spot herbicidal control of some broadleaves and noxious weeds; 3) mowing, fertilizing, and broadleaf control of landscaped lawn areas; 4) weed control in ornamentalmore » shrub areas; and 4) areas requiring only mechanical control to manage unwanted/danger trees, grasses, and shrubs.« less

  3. IEC 61850: Technology Standards and Cyber-Security Threats

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youssef, Tarek A; El Hariri, mohamed; Bugay, Nicole

    Substations constitute a fundamental part in providing reliable electricity to consumers. For a substation to maintain electricity reliability and its own real-time operability, communication between its components is inevitable. Before the emergence of IEC 61850, inter-substation communication was established via expensive copper wires with limited capabilities. IEC 61850 is the standard set by the International Electrotechnical Commission (IEC) Technical Committee Number 57 Working Group 10 and IEEE for Ethernet (IEEE 802.3)-based communication in electrical substations. Like many power grid systems standards, IEC 61850 was set without extensive consideration for critical security measures. This paper discusses IEC 61850 technology standards andmore » applications thoroughly and points out major security vulnerabilities it introduces in the context of current cyber-physical smart grid systems.« less

  4. Relaxation Dynamics in Heme Proteins.

    NASA Astrophysics Data System (ADS)

    Scholl, Reinhard Wilhelm

    A protein molecule possesses many conformational substates that are likely arranged in a hierarchy consisting of a number of tiers. A hierarchical organization of conformational substates is expected to give rise to a multitude of nonequilibrium relaxation phenomena. If the temperature is lowered, transitions between substates of higher tiers are frozen out, and relaxation processes characteristic of lower tiers will dominate the observational time scale. This thesis addresses the following questions: (i) What is the energy landscape of a protein? How does the landscape depend on the environment such as pH and viscosity, and how can it be connected to specific structural parts? (ii) What relaxation phenomena can be observed in a protein? Which are protein specific, and which occur in other proteins? How does the environment influence relaxations? (iii) What functional form best describes relaxation functions? (iv) Can we connect the motions to specific structural parts of the protein molecule, and are these motions important for the function of the protein?. To this purpose, relaxation processes after a pressure change are studied in carbonmonoxy (CO) heme proteins (myoglobin-CO, substrate-bound and substrate-free cytochrome P450cam-CO, chloroperoxidase-CO, horseradish peroxidase -CO) between 150 K and 250 K using FTIR spectroscopy to monitor the CO bound to the heme iron. Two types of p -relaxation experiments are performed: p-release (200 to ~eq40 MPa) and p-jump (~eq40 to 200 MPa) experiments. Most of the relaxations fall into one of three groups and are characterized by (i) nonexponential time dependence and non-Arrhenius temperature dependence (FIM1( nu), FIM1(Gamma)); (ii) exponential time dependence and non-Arrhenius temperature dependence (FIM0(A_{i}to A_{j})); exponential time dependence and Arrhenius temperature dependence (FIMX( nu)). The influence of pH is studied in myoglobin-CO and shown to have a strong influence on the substate population of the highest tier, tier 0, but not on the relaxation rates. Two different viscosities in myoglobin-CO are compared. The dependence of relaxations on the thermodynamic history of a sample is shown. For substrate-free P450cam-CO, relaxations after a p-jump are observed far above the glass transition of the protein-solvent system.

  5. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 56.4130 Electric substations...

  6. 20. Zoo Substation. Philadelphia, Philadelphia Co., PA. Sec. 1101, MP ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    20. Zoo Substation. Philadelphia, Philadelphia Co., PA. Sec. 1101, MP 87.25. - Northeast Railroad Corridor, Amtrak route between Delaware-Pennsylvania & Pennsylvania-New Jersey state lines, Philadelphia, Philadelphia County, PA

  7. Energy storage and alternatives to improve train voltage on a mass transit system

    NASA Astrophysics Data System (ADS)

    Gordon, S. P.; Rorke, W. S.

    1995-04-01

    The wide separation of substations in the Bay Area Rapid Transit system's transbay tunnel contributes to voltage sag when power demand is high. In the future, expansions to the system will exacerbate this problem by increasing traffic density. Typically, this situation is remedied through the installation of additional substations to increase the system's power capacity. We have evaluated the efficacy of several alternatives to this approach - specifically, installation of an 8 megajoule energy storage system, modification of the existing substations, or reduction of the resistance of the running rails or the third rail. To support this analysis, we have developed a simple model of the traction power system in the tunnel. We have concluded that the storage system does not have sufficient capacity to deal with the expected voltage sags; in this application, the alternatives present more effective solutions. We have also investigated the potential impact of these system upgrades on expected future capital outlays by BART for traction power infrastructure additions. We have found that rail or substation upgrades may reduce the need for additional substations. These upgrades may also be effective on other parts of the BART system and on other traction power systems.

  8. 46. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF INFLOW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    46. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF INFLOW CONTROLLER WITH ORIGINAL CAPACITOR BANK. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  9. 125. TRANSFORMER SUBSTATIONS ON NORTH SIDE OF TRANSFORMER ROOM (112), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    125. TRANSFORMER SUBSTATIONS ON NORTH SIDE OF TRANSFORMER ROOM (112), FACING SOUTH - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  10. Long-term observations of bottom conditions and sediment movement on the Atlantic continental shelf; time-lapse photography from instrumented tripod

    USGS Publications Warehouse

    Butman, Bradford; Bryden, Cynthia G.; Pfirman, Stephanie L.; Strahle, William J.; Noble, Marlene A.

    1984-01-01

    An instrument system that measures bottom current, temperature, light transmission, and pressure, and that photographs the bottom at 2- to 6-hour intervals has been developed to study sediment transport on the Atlantic Continental Shelf. Instruments have been deployed extensively along the United States East Coast Continental Shelf for periods of from 2 to 6 months to study the frequency, direction, and rate of bottom sediment movement, and the processes causing movement. The time-lapse photographs are used to (1) characterize the bottom benthic community and surface microtopography; (2) monitor changes in the bottom topography and near-bottom water column caused by currents and storms (for example, ripple generation and migration, sediment resuspension); and (3) monitor seasonal changes in the bottom benthic community and qualitative effects of this community on the bottom sediments.

  11. An instrument system for long-term sediment transport studies on the continental shelf

    USGS Publications Warehouse

    Butman, Bradford; Folger, David W.

    1979-01-01

    A bottom-mounted instrument system has been designed and built to monitor processes of bottom sediment movement on the continental shelf. The system measures bottom current speed and direction, pressure, temperature, and light transmission and photographs the bottom. The system can be deployed for periods of 2–6 months to monitor intermitent processes of sediment movement such as storms and to assess seasonal variability. Deployments of the system on the U.S. east coast continental shelf show sediment resuspension and changes in bottom microtopography due to surface waves, tidal currents, and storms.

  12. On issue of reconstruction at central distribution substation by example of one of plants of Chelyabinsk region

    NASA Astrophysics Data System (ADS)

    Brylina, O. G.; Semenova, K. D.; Shashkin, V. YU

    2018-03-01

    The article considers the issues of increasing the reliability and economy of the distribution substation. The result is found due to the reconstruction of the central distribution substation and one of the plants of Chelyabinsk region. The reasons for the reconstruction are explained. A comparison of oil and vacuum circuit breakers is made. The advantages of vacuum circuit breakers are shown. Alternative replacement of cables is offered. The basic technical characteristics of the cable brands are shown. The results of reconstruction are proved.

  13. 170. Credit SHS. Northern California Power Company substation, Bully Hill ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    170. Credit SHS. Northern California Power Company substation, Bully Hill Mine area. Note lack of vegetation, caused by nearby copper smelting works. - Battle Creek Hydroelectric System, Battle Creek & Tributaries, Red Bluff, Tehama County, CA

  14. NY32649 ELECTRICAL SUBSTATION (BUILDING 2675) AND EDUCATION CENTER (BUILDING 2670) ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NY-326-49 ELECTRICAL SUBSTATION (BUILDING 2675) AND EDUCATION CENTER (BUILDING 2670) AT NORTH END OF ARIZONA AVENUE. VIEW TO NORTHEAST. - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermeston, Mark W.

    BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Covington District of the Snohomish Region. BPA proposes to manage vegetation inside and around electrical substations and associated facilities. Vegetation management within the substations will include bareground management by herbicides of all areas within the fenced perimeter of the facility including a bareground zone of up to 3 meters (10 feet) outside of the fenced area. The management of vegetation outside the substation and associated facilities willmore » include: 1) bare ground management of perimeter roads and parking areas; 2) control of noxious weeds throughout property boundaries; 3) mowing, fertilizing, and weed control of landscaped lawn and mulched areas; 4) weed control in ornamental shrub areas; and 5) areas requiring only mechanical control to manage unwanted/danger trees, grasses, and shrubs.« less

  16. 78 FR 9687 - Prineville Energy Storage, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-11

    ... PDCI to the Ponderosa substation, or (ii) the Bonneville Power Administration (BPA) existing transmission line corridor and then running parallel to the BPA line to the Ponderosa substation; and (9...

  17. POWERHOUSES, SOUTH ELEVATIONS SHOWING OIL HOUSE, FILER SUBSTATION, AND DRAFT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    POWERHOUSES, SOUTH ELEVATIONS SHOWING OIL HOUSE, FILER SUBSTATION, AND DRAFT TUBE OUTLET (TAILRACE), VERTICAL VIEW; FACING WEST - Shoshone Falls Hydroelectric Project, Canyon Road, North Bank of Snake River below Shoshone Falls, Tipperary Corner, Jerome County, ID

  18. 8. VIEW EASTNORTHEAST OF TRANSFORMER BAYS AND SUBSTATION; BUILDING 8 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. VIEW EAST-NORTHEAST OF TRANSFORMER BAYS AND SUB-STATION; BUILDING 8 IS AT EXTREME LEFT CENTER; BUILD-ING 50 IS VISIBLE AT LEFT CENTER BEHIND BUILDING 8 - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT

  19. Study on the system-level test method of digital metering in smart substation

    NASA Astrophysics Data System (ADS)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  20. Advanced Micro Grid Energy Management Coupled with Integrated Volt/VAR Control for Improved Energy Efficiency, Energy Security, and Power Quality at DoD Installations

    DTIC Science & Technology

    2016-10-28

    constraints and wire routing issues. • Outside sites have more space, but require outdoor rated equipment (NEMA outdoor rated.. ) and more maintenance...sustainable power, in many different types, sizes and capacities, as follows: • Cogen Plant #1 B1579: 7.2MW gas-fired turbine at Substation “AA...Cogen Plant #2 B1991: (2) 4.6MW gas-fired turbines at “Gillespie” Substation • 300kW fuel cell at Substation “AA” • PPA: 1.015MW solar photovoltaic

  1. Gauche Ethyl Alcohol: Laboratory Assignments and Interstellar Identification

    NASA Technical Reports Server (NTRS)

    Pearson, J. C.; Sastry, K. V. L. N.; Herbst, Eric; DeLucia, Frank C.

    1997-01-01

    Ethyl alcohol (ethanol) is known to possess a pair of closely spaced excited torsional substates (gauche+, gauche-) at an energy of approximately 57 K above the ground (trans) torsional substate. We report an extended analysis of some gauche - gauche+ Q-branch ((Delta)J = 0) transitions with a three-substate fixed frame axis method (FFAM) Hamiltonian. Our approach accounts for complex trans-gauche interactions for the first time. In addition, we are able to obtain intensities for perturbed rotational transitions, and to determine the trans to gauche+ separation to be 1185399.1 MHz. A complete ground state rotational-torsional partition function accounting for the previously neglected gauche substates is presented. Based on our analysis, a total of 14 U lines obtained towards Orion KL can now be assigned to gauche substates of ethanol. Analysis of these lines yields a rotational temperature of 223 K and a total (trans + gauche) column density of 7.0 x 10(exp 15)/sq cm. The column density is in reasonable agreement with the recent value of 2-3 x 10(exp 15)/sq cm based on observations of trans-ethanol by Ohishi et al., although there is some disparity in the rotational temperatures. Eight additional U lines in the literature are assigned to transitions of gauche ethanol.

  2. 47. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. VIEW OF STAGE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    47. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. VIEW OF STAGE TRANSMITTER AT ALTON, ILLINOIS MODEL SECTION, AND LOCK AND DAM (OLD #26) SIMULATOR. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  3. 7. VIEW OF THE MODERN SUBSTATION (FOREGROUND), WITH THE OLD ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. VIEW OF THE MODERN SUBSTATION (FOREGROUND), WITH THE OLD SWITCHING BUILDING IN THE BACKGROUND, LOOKING SOUTHWEST. - Washington Water Power Company Post Falls Power Plant, Middle Channel Powerhouse & Dam, West of intersection of Spokane & Fourth Streets, Post Falls, Kootenai County, ID

  4. Harmonic Characteristics of Rectifier Substations and Their Impact on Audio Frequency Track Circuits

    DOT National Transportation Integrated Search

    1982-05-01

    This report describes the basic operation of substation rectifier equipment and the modes of possible interference with audio frequency track circuits used for train detection, cab signalling, and vehicle speed control. It also includes methods of es...

  5. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  6. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  7. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  8. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  9. 7 CFR 1710.252 - Construction work plans-power supply borrowers.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... operating systems of supporting power pools and to connect with adjacent power suppliers; (4) Improvements..., new substations and substation improvements and replacements, and Systems Control and Data Acquisition... include studies of load flows, voltage regulation, and stability characteristics to demonstrate system...

  10. The HERMES Polarized Atomic Beam Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nass, A.

    2003-07-30

    The atomic beam source (ABS) provides nuclear polarized hydrogen or deuterium atoms for the HERMES target at flow rates of about 6.5 {center_dot} 1016H-vector/s (hydrogen in two hyperfine substates) and 6.0 {center_dot} 1016D-vector/s (deuterium in three hyperfine substates). The degree of dissociation of 93% for H (95% for D) at the entrance of the storage cell and the nuclear polarization of around 0.97 (H) and 0.92 (D) have been found to be constant within a a couple of percent over the whole running period of the HERMES experiment. A new dissociator (MWD) based on a microwave discharge at 2.45 GHzmore » has been developed and installed into the HERMES-ABS in 2000. Since the velocity distribution of the MWD differs from that of the RFD the intensity could be increased further with a modified sextupole magnet system. For this purpose the way for a new start generator for sextupole tracking calculations was opened. Monte-Carlo simulations were successfully used to describe the gas expansion between nozzle, skimmer and collimator. A new type of beam monitor was used to study the beam formation after the nozzle.« less

  11. 78 FR 50026 - Basin Electric Power Cooperative, Inc.: Notice of Intent To Prepare a Supplemental Draft...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-16

    ... transmission lines, 5 new substations, modifications to 4 existing substations, maintenance access roads... address the construction, operation, and maintenance of Basin Electric's proposed Project. The Project includes construction, operation and maintenance of approximately 275 [[Page 50027

  12. Kennedy Space Center, Space Shuttle Processing, and International Space Station Program Overview

    NASA Technical Reports Server (NTRS)

    Higginbotham, Scott Alan

    2011-01-01

    Topics include: International Space Station assembly sequence; Electrical power substation; Thermal control substation; Guidance, navigation and control; Command data and handling; Robotics; Human and robotic integration; Additional modes of re-supply; NASA and International partner control centers; Space Shuttle ground operations.

  13. A Fuzzy-Based Control Method for Smoothing Power Fluctuations in Substations along High-Speed Railways

    NASA Astrophysics Data System (ADS)

    Sugio, Tetsuya; Yamamoto, Masayoshi; Funabiki, Shigeyuki

    The use of an SMES (Superconducting Magnetic Energy Storage) for smoothing power fluctuations in a railway substation has been discussed. This paper proposes a smoothing control method based on fuzzy reasoning for reducing the SMES capacity at substations along high-speed railways. The proposed smoothing control method comprises three countermeasures for reduction of the SMES capacity. The first countermeasure involves modification of rule 1 for smoothing out the fluctuating electric power to its average value. The other countermeasures involve the modification of the central value of the stored energy control in the SMES and revision of the membership function in rule 2 for reduction of the SMES capacity. The SMES capacity in the proposed smoothing control method is reduced by 49.5% when compared to that in the nonrevised control method. It is confirmed by computer simulations that the proposed control method is suitable for smoothing out power fluctuations in substations along high-speed railways and for reducing the SMES capacity.

  14. 42. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 GALLON PER MINUTE INFLOW CONTROLLER WITH NEW PROGRAMMER, LOCATED ALONG THE NATCHEZ SECTION OF THE MODEL. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  15. Public magnetic field exposure based on internal current density for electric low voltage systems.

    PubMed

    Keikko, Tommi; Seesvuori, Reino; Hyvönen, Martti; Valkealahti, Seppo

    2009-04-01

    A measurement concept utilizing a new magnetic field exposure metering system has been developed for indoor substations where voltage is transformed from a medium voltage of 10 or 20 kV to a low voltage of 400 V. The new metering system follows the guidelines published by the International Commission on Non-Ionizing Radiation Protection. It can be used to measure magnetic field values, total harmonic distortion of the magnetic field, magnetic field exposure ratios for public and workers, load current values, and total harmonic distortion of the load current. This paper demonstrates how exposure to non-sinusoidal magnetic fields and magnetic flux density exposure values can be compared directly with limit values for internal current densities in a human body. Further, we present how the magnetic field and magnetic field exposure behaves in the vicinity of magnetic field sources within the indoor substation and in the neighborhood. Measured magnetic fields around the substation components have been used to develop a measurement concept by which long-term measurements in the substations were performed. Long-term measurements revealed interesting and partly unexpected dependencies between the measured quantities, which have been further analyzed. The principle of this paper is to substitute a demanding exposure measurement with measurements of the basic quantities like the 50 Hz fundamental magnetic field component, which can be estimated based on the load currents for certain classes of substation lay-out.

  16. Long-term geomagnetically induced current observations in New Zealand: Earth return corrections and geomagnetic field driver

    NASA Astrophysics Data System (ADS)

    Mac Manus, Daniel H.; Rodger, Craig J.; Dalzell, Michael; Thomson, Alan W. P.; Clilverd, Mark A.; Petersen, Tanja; Wolf, Moritz M.; Thomson, Neil R.; Divett, Tim

    2017-08-01

    Transpower New Zealand Limited has measured DC currents in transformer neutrals in the New Zealand electrical network at multiple South Island locations. Near-continuous archived DC current data exist since 2001, starting with 12 different substations and expanding from 2009 to include 17 substations. From 2001 to 2015 up to 58 individual transformers were simultaneously monitored. Primarily, the measurements were intended to monitor the impact of the high-voltage DC system linking the North and South Islands when it is operating in "Earth return" mode. However, after correcting for Earth return operation, as described here, the New Zealand measurements provide an unusually long and spatially detailed set of geomagnetically induced current (GIC) measurements. We examine the peak GIC magnitudes observed from these observations during two large geomagnetic storms on 6 November 2001 and 2 October 2013. Currents of 30-50 A are observed, depending on the measurement location. There are large spatial variations in the GIC observations over comparatively small distances, which likely depend upon network layout and ground conductivity. We then go on to examine the GIC in transformers throughout the South Island during more than 151 h of geomagnetic storm conditions. We compare the GIC to the various magnitude and rate of change components of the magnetic field. Our results show that there is a strong correlation between the magnitude of the GIC and the rate of change of the horizontal magnetic field (H'). This correlation is particularly clear for transformers that show large GIC current during magnetic storms.

  17. 43. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    43. MISSISSIPPI BASIN MODEL AT CLINTON SUBSTATION. DETAIL OF 200 GALLON PER MINUTE INFLOW CONTROLLER WITH NEW PROGRAMMER, LOCATED ALONG THE NATCHEZ SECTION OF THE MODEL. NOTE CONTROL BUILDING AT LEFT. - Waterways Experiment Station, Hydraulics Laboratory, Halls Ferry Road, 2 miles south of I-20, Vicksburg, Warren County, MS

  18. 18. Photocopy of photograph showing foundation framing of South Bank ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    18. Photocopy of photograph showing foundation framing of South Bank Substation, 11 June 1939 (from the BPA Photo Archives, Negative No. 347), LOOKING NORTH WITH THE BONNEVILLE DAM POWERHOUSE IN BACKGROUND - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  19. 123. ARAI Substation (ARA726) plan, elevation, security fence details, and ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    123. ARA-I Substation (ARA-726) plan, elevation, security fence details, and sections. Norman Engineering Company 961-area/SF-726-E-1. Date: January 1959. Ineel index code no. 068-0726-10-613-102778. - Idaho National Engineering Laboratory, Army Reactors Experimental Area, Scoville, Butte County, ID

  20. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electric substations and liquid storage...

  1. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electric substations and liquid storage...

  2. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electric substations and liquid storage...

  3. 30 CFR 56.4130 - Electric substations and liquid storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Unburied, flammable or combustible liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable or combustible liquids. (b) The area within the 25-foot perimeter... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electric substations and liquid storage...

  4. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES GUIDELINES FOR DEVELOPMENT AND IMPLEMENTATION OF STATE SOLID WASTE...

  5. 19. Photocopy of photograph showing framing of concrete walls of ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. Photocopy of photograph showing framing of concrete walls of South Bank Substation, 18 July 1939 (from the BPA Photo Archives, Negative No. 365), LOOKING NORTHWEST WITH THE BONNEVILLE DAM POWERHOUSE IN BACKGROUND - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  6. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  7. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  8. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  9. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... liquid storage tanks. (3) Any group of containers used for storage of more than 60 gallons of flammable... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Surface electric substations and liquid storage facilities. 57.4130 Section 57.4130 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF...

  10. 75 FR 7470 - Pine Prairie Energy Center, LLC; Notice of Application

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-19

    ... electric motor drive compressor units instead of the four 4,700 hp natural gas-fueled units previously authorized; (2) construct and operate a new electrical substation at the Pine Prairie Gas Handling Facility and approximately 1,200 feet of aerial electric power lines between the new substation and the...

  11. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 25 2014-07-01 2014-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  12. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 26 2013-07-01 2013-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  13. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 26 2012-07-01 2011-07-01 true Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  14. 40 CFR 256.60 - Requirements for public participation in State and substate plans.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Requirements for public participation in State and substate plans. 256.60 Section 256.60 Protection of Environment ENVIRONMENTAL PROTECTION... shall: (1) Publicize information in news media having broad audiences in the geographic area; (2) Place...

  15. Identification and Single-Cell Functional Characterization of an Endodermally Biased Pluripotent Substate in Human Embryonic Stem Cells.

    PubMed

    Allison, Thomas F; Smith, Andrew J H; Anastassiadis, Konstantinos; Sloane-Stanley, Jackie; Biga, Veronica; Stavish, Dylan; Hackland, James; Sabri, Shan; Langerman, Justin; Jones, Mark; Plath, Kathrin; Coca, Daniel; Barbaric, Ivana; Gokhale, Paul; Andrews, Peter W

    2018-05-09

    Human embryonic stem cells (hESCs) display substantial heterogeneity in gene expression, implying the existence of discrete substates within the stem cell compartment. To determine whether these substates impact fate decisions of hESCs we used a GFP reporter line to investigate the properties of fractions of putative undifferentiated cells defined by their differential expression of the endoderm transcription factor, GATA6, together with the hESC surface marker, SSEA3. By single-cell cloning, we confirmed that substates characterized by expression of GATA6 and SSEA3 include pluripotent stem cells capable of long-term self-renewal. When clonal stem cell colonies were formed from GATA6-positive and GATA6-negative cells, more of those derived from GATA6-positive cells contained spontaneously differentiated endoderm cells than similar colonies derived from the GATA6-negative cells. We characterized these discrete cellular states using single-cell transcriptomic analysis, identifying a potential role for SOX17 in the establishment of the endoderm-biased stem cell state. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  16. SHARD - a SeisComP3 module for Structural Health Monitoring

    NASA Astrophysics Data System (ADS)

    Weber, B.; Becker, J.; Ellguth, E.; Henneberger, R.; Herrnkind, S.; Roessler, D.

    2016-12-01

    Monitoring building and structure response to strong earthquake ground shaking or human-induced vibrations in real-time forms the backbone of modern structural health monitoring (SHM). The continuous data transmission, processing and analysis reduces drastically the time decision makers need to plan for appropriate response to possible damages of high-priority buildings and structures. SHARD is a web browser based module using the SeisComp3 framework to monitor the structural health of buildings and other structures by calculating standard engineering seismology parameters and checking their exceedance in real-time. Thresholds can be defined, e.g. compliant with national building codes (IBC2000, DIN4149 or EC8), for PGA/PGV/PGD, response spectra and drift ratios. In case thresholds are exceeded automatic or operator driven reports are generated and send to the decision makers. SHARD also determines waveform quality in terms of data delay and variance to report sensor status. SHARD is the perfect tool for civil protection to monitor simultaneously multiple city-wide critical infrastructure as hospitals, schools, governmental buildings and structures as bridges, dams and power substations.

  17. Instrumenting free-swimming dolphins echolocating in open water.

    PubMed

    Martin, Stephen W; Phillips, Michael; Bauer, Eric J; Moore, Patrick W; Houser, Dorian S

    2005-04-01

    Dolphins within the Navy Marine Mammal Program use echolocation to effectively locate underwater mines. They currently outperform manmade systems at similar tasks, particularly in cluttered environments and on buried targets. In hopes of improving manmade mine-hunting sonar systems, two instrumentation packages were developed to monitor free-swimming dolphin motion and echolocation during open-water target detection tasks. The biosonar measurement tool (BMT) is carried by a dolphin and monitors underwater position and attitude while simultaneously recording echolocation clicks and returning echoes through high-gain binaural receivers. The instrumented mine simulator (IMS) is a modified bottom target that monitors echolocation signals arriving at the target during ensonification. Dolphin subjects were trained to carry the BMT in open-bay bottom-object target searches in which the IMS could serve as a bottom object. The instrumentation provides detailed data that reveal hereto-unavailable information on the search strategies of free-swimming dolphins conducting open-water, bottom-object search tasks with echolocation.

  18. Instrumenting free-swimming dolphins echolocating in open water

    NASA Astrophysics Data System (ADS)

    Martin, Stephen W.; Phillips, Michael; Bauer, Eric J.; Moore, Patrick W.; Houser, Dorian S.

    2005-04-01

    Dolphins within the Navy Marine Mammal Program use echolocation to effectively locate underwater mines. They currently outperform manmade systems at similar tasks, particularly in cluttered environments and on buried targets. In hopes of improving manmade mine-hunting sonar systems, two instrumentation packages were developed to monitor free-swimming dolphin motion and echolocation during open-water target detection tasks. The biosonar measurement tool (BMT) is carried by a dolphin and monitors underwater position and attitude while simultaneously recording echolocation clicks and returning echoes through high-gain binaural receivers. The instrumented mine simulator (IMS) is a modified bottom target that monitors echolocation signals arriving at the target during ensonification. Dolphin subjects were trained to carry the BMT in open-bay bottom-object target searches in which the IMS could serve as a bottom object. The instrumentation provides detailed data that reveal hereto-unavailable information on the search strategies of free-swimming dolphins conducting open-water, bottom-object search tasks with echolocation. .

  19. NREL and Sandia National Laboratories (SNL) Support of Ocean Renewable Power Company's TidGen™ Power System Technology Readiness Advancement Initiative Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    LiVecchi, Al

    2015-05-07

    This document summarizes the tasks identified for National Laboratory technical support of Ocean Renewable Power Corporation (ORPC) DOE grant awarded under the FY10 Industry Solicitation DE-FOA-0000293: Technology Readiness Advancement Initiative. The system ORPC will deploy in Cobscook Bay, ME is known as the TidGen™ Power System. The Turbine Generator Unit (TGU) each have a rated capacity of 150 to 175 kW, and they are mounted on bottom support frames and connected to an onshore substation using an underwater power and control cable. This system is designed for tidal energy applications in water depths from 60 to 150 feet. In fundingmore » provided separately by DOE, National Laboratory partners NREL and SNL will provide in-kind resources and technical expertise to help ensure that industry projects meet DOE WWPP (Wind and Water Power Program) objectives by reducing risk to these high value projects.« less

  20. 77 FR 73651 - Cascade Energy Storage, LLC; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-11

    ... City Light's existing 230-kV transmission line, or (ii) Bonneville Power Administration's (BPA) existing Custer-Monroe 500-kV line, or (iii) BPA existing Murray substation, or (iv) a new 4.5-mile- long... and then to the BPA Murray substation; and (9) appurtenant facilities. The estimated annual generation...

  1. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-74)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-07-01

    Vegetation Management for five Substations in the Malin District. BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Malin District of the Redmond Region.

  2. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-82)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-08-13

    Vegetation Management for twenty-four Substations in the Burley District. BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Burley District of the Idaho Falls Region.

  3. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-78)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-07-01

    Vegetation Management for ten Substations in the Redmond District. BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Redmond District of the Redmond Region.

  4. AeroVironment's Jim Daley, Rik Meininger, Derek Lisoski and Wyatt Sadler (clockwise from bottom left) closely monitor systems testing of the Pathfinder-Plus.

    NASA Image and Video Library

    2004-09-17

    AeroVironment's test director Jim Daley, backup pilot Rik Meininger, stability and controls engineer Derek Lisoski and pilot Wyatt Sadler (clockwise from bottom left) closely monitor systems testing of the Pathfinder-Plus solar aircraft from the control station.

  5. A new test procedure to evaluate the performance of substations for collective heating systems

    NASA Astrophysics Data System (ADS)

    Baetens, Robin; Verhaert, Ivan

    2017-11-01

    The overall heat demand of a single dwelling, existing out of space heating and domestic hot water production, decreases due to higher insulation rates. Because of this, investing in efficient and renewable heat generation becomes less interesting. Therefore, to incorporate renewables or residual heat on a larger scale, district heating or collective heating systems grow in importance. Within this set-up, the substation is responsible for the interaction between local demand for comfort and overall energy performance of the collective heating system. Many different configurations of substations exist, which influence both local comfort and central system performance. Next to that, also hybrids exist with additional local energy input. To evaluate performance of such substations, a new experimental-based test procedure is developed in order to evaluate these different aspects, characterized by the two roles a substation has, namely as heat generator and as heat consumer. The advantage of this approach is that an objective comparison between individual and central systems regarding performance on delivering local comfort can be executed experimentally. The lab set-up consists out of three different subsystems, namely the central system, the domestic hot water consumption and the local space heating. The central system can work with different temperature regimes and control strategies, as these aspects have proven to have the largest influence on actual performance. The domestic hot water system is able to generate similar tap profiles according to eco-design regulation for domestic hot water generation. The space heating system is able to demand a modular heat load.

  6. 16. EXTERIOR NORTH END OF TULE RIVER POWERHOUSE SHOWING POWERHOUSE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    16. EXTERIOR NORTH END OF TULE RIVER POWERHOUSE SHOWING POWERHOUSE AT PHOTO CENTER, SUBSTATION AT PHOTO RIGHT FOREGROUND, OFFICE BEHIND SUBSTATION AT RIGHT OF POWERHOUSE, AND MACHINE SHOP AT LEFT OF POWERHOUSE. THIS PHOTOGRAPH DUPLICATES HISTORIC VIEW SHOWN IN PHOTO CA-216-17. VIEW TO SOUTHEAST. - Tule River Hydroelectric Project, Water Conveyance System, Middle Fork Tule River, Springville, Tulare County, CA

  7. Procedures and criteria for increasing the earthquake resistance level of electrical substations and special installations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Couch, R.W.; Deacon, R.J.

    1973-09-30

    This report defines a procedure and provides basic information needed to determine the modifications required to make electrical substations and special installations of the Bonneville Power Administration (BPA) more resistant to strong earthquake ground motion. It also provides a procedure for developing an effective plan for establishing the sequence, or priority, of providing the required modifications.

  8. 78 FR 70546 - Erie Boulevard Hydropower, L.P.; Notice of Application Accepted for Filing, Soliciting Motions To...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-26

    ... (kV) generator leads extending about 25 feet to an adjacent electrical substation containing a 2.4/4.8-kV, 600-kilovolt-amperes, step-up transformer bank. A transmission line owned and operated by... with the electrical grid at the substation. At the time the Commission issued the original license for...

  9. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-96) - Snohomish District Substations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hermeston, Mark W.

    2002-07-19

    Proposed Action: Vegetation Management for facilities located in the Snohomish District. BPA proposes total vegetation management (bareground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within the Snohomish District of the Snohomish Region.

  10. Independent Power Generation in a Modern Electrical Substation Based on Thermoelectric Technology

    NASA Astrophysics Data System (ADS)

    Li, Z. M.; Zhao, Y. Q.; Liu, W.; Wei, B.; Qiu, M.; Lai, X. K.

    2017-05-01

    Because of many types of electrical equipment with high power in substations, the potentiality of energy conservation is quite large. From this viewpoint, thermoelectric materials may be chosen to produce electrical energy using the waste heat produced in substations. Hence, a thermoelectric generation system which can recycle the waste heat from electric transformers was proposed to improve the energy efficiency and reduce the burden of the oil cooling system. An experimental prototype was fabricated to perform the experiment and to verify the feasibility. The experimental results showed that the output power could achieve 16 W from waste heat of 900 W, and that the power conversion efficiency was approximately 1.8%. Therefore, power generation is feasible by using the waste heat from the transformers based on thermoelectric technology.

  11. 78 FR 62348 - Erie Boulevard Hydropower L.P.; Notice of Application Tendered for Filing With the Commission and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-18

    ... 100 feet; and (7) 2.4-kilovolt (kV) generator leads extending about 25 feet to an adjacent electrical substation containing a 2.4/4.8-kV, 600-kilovolt-amperes, step-up transformer bank. A transmission line owned... project interconnects with the electrical grid at the substation. At the time the Commission issued the...

  12. Service Building No. 620. Detail of north elevation and entrance ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Service Building No. 620. Detail of north elevation and entrance to substation & windowns in top of elevator shafts no. 2 & stair no. 1 & section thru substation (dry dock associates, June 12, 1941). In files of Cushman & Wakefield, building 501, Philadelphia Naval Business Center. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Service Building, Dry Docks No. 4 & 5, League Island, Philadelphia, Philadelphia County, PA

  13. Design of a two-level power system linear state estimator

    NASA Astrophysics Data System (ADS)

    Yang, Tao

    The availability of synchro-phasor data has raised the possibility of a linear state estimator if the inputs are only complex currents and voltages and if there are enough such measurements to meet observability and redundancy requirements. Moreover, the new digital substations can perform some of the computation at the substation itself resulting in a more accurate two-level state estimator. The objective of this research is to develop a two-level linear state estimator processing synchro-phasor data and estimating the states at both the substation level and the control center level. Both the mathematical algorithms that are different from those in the present state estimation procedure and the layered architecture of databases, communications and application programs that are required to support this two-level linear state estimator are described in this dissertation. Besides, as the availability of phasor measurements at substations will increase gradually, this research also describes how the state estimator can be enhanced to handle both the traditional state estimator and the proposed linear state estimator simultaneously. This provides a way to immediately utilize the benefits in those parts of the system where such phasor measurements become available and provides a pathway to transition to the smart grid of the future. The design procedure of the two-level state estimator is applied to two study systems. The first study system is the IEEE-14 bus system. The second one is the 179 bus Western Electricity Coordinating Council (WECC) system. The static database for the substations is constructed from the power flow data of these systems and the real-time measurement database is produced by a power system dynamic simulating tool (TSAT). Time-skew problems that may be caused by communication delays are also considered and simulated. We used the Network Simulator (NS) tool to simulate a simple communication system and analyse its time delay performance. These time delays were too small to affect the results especially since the measurement data is time-stamped and the state estimator for these small systems could be run with subseconf frequency. Keywords: State Estimation, Synchro-Phasor Measurement, Distributed System, Energy Control Center, Substation, Time-skew

  14. Architecture and Methods for Substation SCADA Cybersecurity: Best Practices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Albunashee, Hamdi; Al Sarray, Muthanna; McCann, Roy

    There are over 3000 electricity providers in the United States, encompassing investor and publicly owned utilities as well as electric cooperatives. There has been ongoing trends to increasingly automate and provide remote control and monitoring of electric energy delivery systems. The deployment of computer network technologies has increased the efficiency and reliability of electric power infrastructure. However, the increased use of digital communications has also increased the vulnerability to malicious cyber attacks [1]. In 2004 the National Research Councils (National Academies) formed a committee of specialists to address these vulnerabilities and propose possible solutions with an objective to prioritize themore » R&D needs for developing countermeasures. The committee addressed many potential concerns in the electric power delivery system and classified them based upon different criteria and presented recommendations to minimize the gap between the academic research directions and the needs of the electric utility industry. The complexity and diversity of the electric power delivery system in the U.S. has opened many ports for attackers and intruders [1]. This complexity and diversity is attributed to the fact that power delivery system is a network of substations, transmission and distribution lines, sub-networks of controlling, sensing and monitoring units, and human operator involvement for running the system [1]. Accordingly, any incident such as the occurrence of a fault or disturbance in this complex network cannot be deferred and should be resolved within an order of milliseconds, otherwise there is risk of large-scale outages similar to the occurrences in India and the U.S. in 2003 [2]. There are three main vulnerabilities in supervisory control and data acquisition (SCADA) systems commonly identified—physical vulnerability, cyber vulnerability and personal vulnerability [1]. In terms of cyber threats, SCADA systems are the most critical elements in the electric power grid in the U.S. Unauthorized access to a SCADA system could enable/disable unexpected equipment (such as disable the protection system or a circuit breaker) which could cause large scale disruptions of electric power delivery. This paper provides an overview of power system SCADA technologies in transmission substations (Section 2) and summarizes the best practices for implementing a cyber security program. After introducing SCADA system operations in Section 2, a description of the security challenges for SCADA systems is presented in Section 3. In Section 4, NECRC Critical Infrastructure Protection standards CIP-002 through CIP-009 are summarized. An overview of industry best practices is presented in Section 5.« less

  15. Implementation of Non-Destructive Evaluation and Process Monitoring in DLP-based Additive Manufacturing

    NASA Astrophysics Data System (ADS)

    Kovalenko, Iaroslav; Verron, Sylvain; Garan, Maryna; Šafka, Jiří; Moučka, Michal

    2017-04-01

    This article describes a method of in-situ process monitoring in the digital light processing (DLP) 3D printer. It is based on the continuous measurement of the adhesion force between printing surface and bottom of a liquid resin bath. This method is suitable only for the bottom-up DPL printers. Control system compares the force at the moment of unsticking of printed layer from the bottom of the tank, when it has the largest value in printing cycle, with theoretical value. Implementation of suggested algorithm can make detection of faults during the printing process possible.

  16. Hazard zoning around electric substations of petrochemical industries by stimulation of extremely low-frequency magnetic fields.

    PubMed

    Hosseini, Monireh; Monazzam, Mohammad Reza; Farhang Matin, Laleh; Khosroabadi, Hossein

    2015-05-01

    Electromagnetic fields in recent years have been discussed as one of the occupational hazards at workplaces. Hence, control and assessment of these physical factors is very important to protect and promote the health of employees. The present study was conducted to determine hazard zones based on assessment of extremely low-frequency magnetic fields at electric substations of a petrochemical complex in southern Iran, using the single-axis HI-3604 device. In measurement of electromagnetic fields by the single-axis HI-3604 device, the sensor screen should be oriented in a way to be perpendicular to the field lines. Therefore, in places where power lines are located in different directions, it is required to keep the device towards three axes of x, y, and z. For further precision, the measurements should be repeated along each of the three axes. In this research, magnetic field was measured, for the first time, in three axes of x, y, and z whose resultant value was considered as the value of magnetic field. Measurements were done based on IEEE std 644-1994. Further, the spatial changes of the magnetic field surrounding electric substations were stimulated using MATLAB software. The obtained results indicated that the maximum magnetic flux density was 49.90 μT recorded from boiler substation, while the minimum magnetic flux density of 0.02 μT was measured at the control room of the complex. As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations.

  17. Inter and intra substation communications: Requirements and solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Adamiak, M.; Patterson, R.; Melcher, J.

    1995-10-01

    As the substation communication world searches for the ``Promised LAN,`` it would be helpful to have a roadmap to give direction to the search. Many are the expectations of a LAN flowing with data and able to connect with any Intelligent Electronic Device (IED) that was ever made. Such expectations must be tempered with the cost and complexity of achieving them. This paper presents an outline of the communication requirements of the myriad of IED`s in existence in the substation today as well as the expectations of what second generation microprocessor based devices might be able to do. Requirements willmore » focus on language issues, system capabilities, performance requirements, external interfaces, environmental, and quality issues. Some attention will also be given to the architecture of a solution and some guidelines as to how this structure might be built.« less

  18. Autonomous navigation method for substation inspection robot based on travelling deviation

    NASA Astrophysics Data System (ADS)

    Yang, Guoqing; Xu, Wei; Li, Jian; Fu, Chongguang; Zhou, Hao; Zhang, Chuanyou; Shao, Guangting

    2017-06-01

    A new method of edge detection is proposed in substation environment, which can realize the autonomous navigation of the substation inspection robot. First of all, the road image and information are obtained by using an image acquisition device. Secondly, the noise in the region of interest which is selected in the road image, is removed with the digital image processing algorithm, the road edge is extracted by Canny operator, and the road boundaries are extracted by Hough transform. Finally, the distance between the robot and the left and the right boundaries is calculated, and the travelling distance is obtained. The robot's walking route is controlled according to the travel deviation and the preset threshold. Experimental results show that the proposed method can detect the road area in real time, and the algorithm has high accuracy and stable performance.

  19. Energy Saving in DC Electric Railways by Battery Substation

    NASA Astrophysics Data System (ADS)

    Sugimoto, Takeshi

    New rolling vehicles used in dc electric railways are of the regenerative type. At less busy time a part of regenerative power is not used for powering vehicles, and canceled by changed air brake. Recently, significant attention has been paid to the development of secondary batteries for hybrid and electric motorcars. The use of this battery enables reduction in electric power consumption. Because we can charge excess regenerative power and use for powering vehicles after. Before the fact we compared the actual and simulated effective coefficient of regenerative energy, we confirmed the suitability of the simulation model. In this simulation, we studied the energy-saving effect of the battery substations and determined the battery capacity at which maximum power saving is achieved. We found that the power consumption could be reduced remarkably by using a 15-20kWh battery substation.

  20. USSR and Eastern Europe Scientific Abstracts, Cybernetics, Computers and Automation Technology, Number 31

    DTIC Science & Technology

    1978-02-09

    incorporation of subsystems and tasks into systems are specified by state and industrial- sector standards. However, such rigid requirements interfere...construction of the step-down substation, without which the new sector is inoperable. The question of who will build the substation is still unresolved... economico -mathematical evaluation). Among such applications, program decks completed by the "Soyuzsistemprom" are those for data integra- tion and

  1. New model of inverting substation for DC traction with regenerative braking system

    NASA Astrophysics Data System (ADS)

    Omar, Abdul Malek Saidina; Samat, Ahmad Asri Abd; Isa, Siti Sarah Mat; Shamsuddin, Sarah Addyani; Jamaludin, Nur Fadhilah; Khyasudeen, Muhammad Farris

    2017-08-01

    This paper presents a power electronic devices application focus on modeling, analysis, and control of switching power converter in the inverting DC substation with regenerative braking system which is used to recycle the surplus regenerative power by feed it back to the main AC grid. The main objective of this research is to improve the switching power electronic converter of the railway inverting substation and optimize the maximum kinetic energy recovery together with minimum power losses from the railway braking system. Assess performance including efficiency and robustness will be evaluated in order to get the best solution for the design configuration. Research methodology included mathematical calculation, simulation, and detail analysis on modeling of switching power converter on inverting substation. The design stage separates to four main areas include rectification mode, regenerative mode, control inverter mode and filtering mode. The simulation result has shown that the regenerative inverter has a capability to accept a maximum recovery power on the regeneration mode. Total energy recovery has increase and power losses have decreases because inverter abilities to transfer the surplus energy back to the main AC supply. An Inverter controller with PWM Generator and PI Voltage Regulator has been designed to control voltage magnitude and frequency of the DC traction system.

  2. A comparative study of electric load curve changes in an urban low-voltage substation in Spain during the economic crisis (2008-2013).

    PubMed

    Lara-Santillán, Pedro M; Mendoza-Villena, Montserrat; Fernández-Jiménez, L Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008-2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002-2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period.

  3. Draft Supplement to the Environmental Statement Fiscal Year 1976 Proposed Program : Facilty Location Evaluation for Franklin-Badger Canyon 230-kV Line and Badger Canyon Substation Study Area 74-6B.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1974-10-22

    Proposed is the construction of a 15-mile, 230-kV double-circuit transmission line from Franklin Substation near Pasco, Washington, to a proposed new Badger Canyon Substation to be constructed 5 miles west of Kennewick, Washington. Depending on the final route location chosen, approximately 15 miles of 230-kV double circuit transmission line requiring 5.6 miles of new and 9.4 miles of existing right-of-way would be needed as well as approximately 2500 feet of new access road. Land use affected includes crossing Sacajawea State Park and passig through irrigated cropland and grassland on existing right-of-way, and depending on the alternative route chosen, could crossmore » land proposed for residential development and a proposed interstate highway. An additional 10 to 11 acres of potential cropland would be required for the proposed substation. Disturbance to wildlife during construction would occur and habitat associated with the above land uses would be eliminated. Some erosion and sedimentation would occur. Visual impacts would affect Sacajawea State Park, a proposed highway, and potential residential development land. Noise and other disturbances to residents will occur, primarily during construction.« less

  4. Kinematic analysis and simulation of a substation inspection robot guided by magnetic sensor

    NASA Astrophysics Data System (ADS)

    Xiao, Peng; Luan, Yiqing; Wang, Haipeng; Li, Li; Li, Jianxiang

    2017-01-01

    In order to improve the performance of the magnetic navigation system used by substation inspection robot, the kinematic characteristics is analyzed based on a simplified magnetic guiding system model, and then the simulation process is executed to verify the reasonability of the whole analysis procedure. Finally, some suggestions are extracted out, which will be helpful to guide the design of the inspection robot system in the future.

  5. 20 CFR 645.210 - What is meant by the terms “entity” and “project” in the statutory phrase “an entity that...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... a project”, means: (a) For WtW substate formula funds: (1) “Entity” means the PIC, local board (or... to § 645.400 of this part) which administers the WtW substate formula funds in a local area(s). This... formula funds allotted to the entity described in section (a)(1) of this paragraph. (b) For WtW Governors...

  6. 20 CFR 645.210 - What is meant by the terms “entity” and “project” in the statutory phrase “an entity that...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... a project”, means: (a) For WtW substate formula funds: (1) “Entity” means the PIC, local board (or... to § 645.400 of this part) which administers the WtW substate formula funds in a local area(s). This... formula funds allotted to the entity described in section (a)(1) of this paragraph. (b) For WtW Governors...

  7. Supplemental Environmental Assessment: Lighthouse Substation Cape Canaveral Air Force Station Florida

    DTIC Science & Technology

    2007-10-01

    associated with transmission lines is generally due to either corona or “spark gap” discharges. When the electric field at the surface of a conductor... corona , will be initiated from the conductor into the Chapter 3: Affected Environment Supplemental Environmental Assessment – Lighthouse Substation at...Cape Canaveral Air Force Station 24 surrounding air. The intensity of the corona increases with the voltage of the line and is dependent on the

  8. Two-way communication and analysis program on LANDSAT

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Community workshops, field visits, telephone surveys, and other research reveals that professionals at the substate level are interested in and open to consideration of LANDSAT as a planning and resource management tool, but are at the same time skeptical about some of the inherent problems with LANDSAT such as cost, resolution, frequency of coverage, and data continuity. The principal requirements for increasing the utilization of LANDSAT by potential substate users were identified and documented. Without a committment from the Federal Government for increased substrate utilization and the availability of trained professionals to meet the needs of a largely new user community, substrate activity is likely to remain at a minimum. Well conceived and well executed demonstration projects could play a critical role is shaping the technology's ability to be more sensitive to substate user needs and interests as well as validating the effectiveness of this data to a skeptical audience.

  9. Tracking problem solving by multivariate pattern analysis and Hidden Markov Model algorithms.

    PubMed

    Anderson, John R

    2012-03-01

    Multivariate pattern analysis can be combined with Hidden Markov Model algorithms to track the second-by-second thinking as people solve complex problems. Two applications of this methodology are illustrated with a data set taken from children as they interacted with an intelligent tutoring system for algebra. The first "mind reading" application involves using fMRI activity to track what students are doing as they solve a sequence of algebra problems. The methodology achieves considerable accuracy at determining both what problem-solving step the students are taking and whether they are performing that step correctly. The second "model discovery" application involves using statistical model evaluation to determine how many substates are involved in performing a step of algebraic problem solving. This research indicates that different steps involve different numbers of substates and these substates are associated with different fluency in algebra problem solving. Copyright © 2011 Elsevier Ltd. All rights reserved.

  10. Analysis of Acoustic Emission Parameters from Corrosion of AST Bottom Plate in Field Testing

    NASA Astrophysics Data System (ADS)

    Jomdecha, C.; Jirarungsatian, C.; Suwansin, W.

    Field testing of aboveground storage tank (AST) to monitor corrosion of the bottom plate is presented in this chapter. AE testing data of the ten AST with different sizes, materials, and products were employed to monitor the bottom plate condition. AE sensors of 30 and 150 kHz were used to monitor the corrosion activity of up to 24 channels including guard sensors. Acoustic emission (AE) parameters were analyzed to explore the AE parameter patterns of occurring corrosion compared to the laboratory results. Amplitude, count, duration, and energy were main parameters of analysis. Pattern recognition technique with statistical was implemented to eliminate the electrical and environmental noises. The results showed the specific AE patterns of corrosion activities related to the empirical results. In addition, plane algorithm was utilized to locate the significant AE events from corrosion. Both results of parameter patterns and AE event locations can be used to interpret and locate the corrosion activities. Finally, basic statistical grading technique was used to evaluate the bottom plate condition of the AST.

  11. Shallow water bathymetry correction using sea bottom classification with multispectral satellite imagery

    NASA Astrophysics Data System (ADS)

    Kazama, Yoriko; Yamamoto, Tomonori

    2017-10-01

    Bathymetry at shallow water especially shallower than 15m is an important area for environmental monitoring and national defense. Because the depth of shallow water is changeable by the sediment deposition and the ocean waves, the periodic monitoring at shoe area is needed. Utilization of satellite images are well matched for widely and repeatedly monitoring at sea area. Sea bottom terrain model using by remote sensing data have been developed and these methods based on the radiative transfer model of the sun irradiance which is affected by the atmosphere, water, and sea bottom. We adopted that general method of the sea depth extraction to the satellite imagery, WorldView-2; which has very fine spatial resolution (50cm/pix) and eight bands at visible to near-infrared wavelengths. From high-spatial resolution satellite images, there is possibility to know the coral reefs and the rock area's detail terrain model which offers important information for the amphibious landing. In addition, the WorldView-2 satellite sensor has the band at near the ultraviolet wavelength that is transmitted through the water. On the other hand, the previous study showed that the estimation error by the satellite imagery was related to the sea bottom materials such as sand, coral reef, sea alga, and rocks. Therefore, in this study, we focused on sea bottom materials, and tried to improve the depth estimation accuracy. First, we classified the sea bottom materials by the SVM method, which used the depth data acquired by multi-beam sonar as supervised data. Then correction values in the depth estimation equation were calculated applying the classification results. As a result, the classification accuracy of sea bottom materials was 93%, and the depth estimation error using the correction by the classification result was within 1.2m.

  12. A Comparative Study of Electric Load Curve Changes in an Urban Low-Voltage Substation in Spain during the Economic Crisis (2008–2013)

    PubMed Central

    Lara-Santillán, Pedro M.; Mendoza-Villena, Montserrat; Fernández-Jiménez, L. Alfredo; Mañana-Canteli, Mario

    2014-01-01

    This paper presents a comparative study of the electricity consumption (EC) in an urban low-voltage substation before and during the economic crisis (2008–2013). This low-voltage substation supplies electric power to near 400 users. The EC was measured for an 11-year period (2002–2012) with a sampling time of 1 minute. The study described in the paper consists of detecting the changes produced in the load curves of this substation along the time due to changes in the behaviour of consumers. The EC was compared using representative curves per time period (precrisis and crisis). These representative curves were obtained after a computational process, which was based on a search for days with similar curves to the curve of a determined (base) date. This similitude was assessed by the proximity on the calendar, day of the week, daylight time, and outdoor temperature. The last selection parameter was the error between the nearest neighbour curves and the base date curve. The obtained representative curves were linearized to determine changes in their structure (maximum and minimum consumption values, duration of the daily time slot, etc.). The results primarily indicate an increase in the EC in the night slot during the summer months in the crisis period. PMID:24895677

  13. National Maglev initiative: California line electric utility power system requirements

    NASA Technical Reports Server (NTRS)

    Save, Phil

    1994-01-01

    The electrical utility power system requirements were determined for a Maglev line from San Diego to San Francisco and Sacramento with a maximum capacity of 12,000 passengers an hour in each direction at a speed of 300 miles per hour, or one train every 30 seconds in each direction. Basically the Maglev line requires one 50-MVA substation every 12.5 miles. The need for new power lines to serve these substations and their voltage levels are based not only on equipment loading criteria but also on limitations due to voltage flicker and harmonics created by the Maglev system. The resulting power system requirements and their costs depend mostly on the geographical area, urban or suburban with 'strong' power systems, or mountains and rural areas with 'weak' power systems. A reliability evaluation indicated that emergency power sources, such as a 10-MW battery at each substation, were not justified if sufficient redundancy is provided in the design of the substations and the power lines serving them. With a cost of $5.6 M per mile, the power system requirements, including the 12-kV DC cables and the inverters along the Maglev line, were found to be the second largest cost component of the Maglev system, after the cost of the guideway system ($9.1 M per mile), out of a total cost of $23 M per mile.

  14. Efficient evaluation of sampling quality of molecular dynamics simulations by clustering of dihedral torsion angles and Sammon mapping.

    PubMed

    Frickenhaus, Stephan; Kannan, Srinivasaraghavan; Zacharias, Martin

    2009-02-01

    A direct conformational clustering and mapping approach for peptide conformations based on backbone dihedral angles has been developed and applied to compare conformational sampling of Met-enkephalin using two molecular dynamics (MD) methods. Efficient clustering in dihedrals has been achieved by evaluating all combinations resulting from independent clustering of each dihedral angle distribution, thus resolving all conformational substates. In contrast, Cartesian clustering was unable to accurately distinguish between all substates. Projection of clusters on dihedral principal component (PCA) subspaces did not result in efficient separation of highly populated clusters. However, representation in a nonlinear metric by Sammon mapping was able to separate well the 48 highest populated clusters in just two dimensions. In addition, this approach also allowed us to visualize the transition frequencies between clusters efficiently. Significantly, higher transition frequencies between more distinct conformational substates were found for a recently developed biasing-potential replica exchange MD simulation method allowing faster sampling of possible substates compared to conventional MD simulations. Although the number of theoretically possible clusters grows exponentially with peptide length, in practice, the number of clusters is only limited by the sampling size (typically much smaller), and therefore the method is well suited also for large systems. The approach could be useful to rapidly and accurately evaluate conformational sampling during MD simulations, to compare different sampling strategies and eventually to detect kinetic bottlenecks in folding pathways.

  15. Supplemental Information for New York State Standardized Interconnection Requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ingram, Michael; Narang, David J.; Mather, Barry A.

    This document is intended to aid in the understanding and application of the New York State Standardized Interconnection Requirements (SIR) and Application Process for New Distributed Generators 5 MW or Less Connected in Parallel with Utility Distribution Systems, and it aims to provide supplemental information and discussion on selected topics relevant to the SIR. This guide focuses on technical issues that have to date resulted in the majority of utility findings within the context of interconnecting photovoltaic (PV) inverters. This guide provides background on the overall issue and related mitigation measures for selected topics, including substation backfeeding, anti-islanding and considerationsmore » for monitoring and controlling distributed energy resources (DER).« less

  16. Modelling GIC Flow in New Zealand's Electrical Transmission Grid

    NASA Astrophysics Data System (ADS)

    Divett, T.; Thomson, A. W. P.; Ingham, M.; Rodger, C. J.; Beggan, C.; Kelly, G.

    2016-12-01

    Transformers in Transpower New Zealand Ltd's electrical grid have been impacted by geomagnetically induced currents (GIC) during geomagnetic storms, for example in November 2001. In this study we have developed an initial model of the South Island's power grid to advance understanding of the impact of GIC on New Zealand's (NZ) grid. NZ's latitude and island setting mean that modelling approaches successfully used in the UK in the past can be used. Vasseur and Weidelt's thin sheet model is applied to model the electric field as a function of magnetic field and conductance. However the 4 km deep ocean near NZ's coast compared to the UK's relatively shallow continental shelf waters restricts the range of frequency and spatial grid that can be used due to assumptions in the thin sheet model. Some early consequences of these restrictions will be discussed. Lines carrying 220kV, 110kV and 66kV make up NZ's electrical transmission grid with multiple earthing nodes at each substation. Transpower have measured DC earth currents at 17 nodes in NZ's South Island grid for 15 years, including observations at multiple transformers for some substations. Different transformers at the same substation can experience quite different GIC during space weather events. Therefore we have initially modelled each transformer in some substations separately to compare directly with measured currents.Ultimately this study aims to develop a validated modelling tool that will be used to strengthen NZ's grid against the risks of space weather. Further, mitigation tactics which could be used to reduce the threat to the electrical grid will be evaluated. In particular we will focus at the transformer level where the risk lies, and not at the substation level as has been commonly done to date. As we will validate our model against the extensive Transpower observations, this will be a valuable confirmation of the approaches used by the wider international community.

  17. The research of full automatic oil filtering control technology of high voltage insulating oil

    NASA Astrophysics Data System (ADS)

    Gong, Gangjun; Zhang, Tong; Yan, Guozeng; Zhang, Han; Chen, Zhimin; Su, Chang

    2017-09-01

    In this paper, the design scheme of automatic oil filter control system for transformer oil in UHV substation is summarized. The scheme specifically includes the typical double tank filter connection control method of the transformer oil of the UHV substation, which distinguishes the single port and the double port connection structure of the oil tank. Finally, the design scheme of the temperature sensor and respirator is given in detail, and the detailed evaluation and application scenarios are given for reference.

  18. Image acquisition device of inspection robot based on adaptive rotation regulation of polarizer

    NASA Astrophysics Data System (ADS)

    Dong, Maoqi; Wang, Xingguang; Liang, Tao; Yang, Guoqing; Zhang, Chuangyou; Gao, Faqin

    2017-12-01

    An image processing device of inspection robot with adaptive polarization adjustment is proposed, that the device includes the inspection robot body, the image collecting mechanism, the polarizer and the polarizer automatic actuating device. Where, the image acquisition mechanism is arranged at the front of the inspection robot body for collecting equipment image data in the substation. Polarizer is fixed on the automatic actuating device of polarizer, and installed in front of the image acquisition mechanism, and that the optical axis of the camera vertically goes through the polarizer and the polarizer rotates with the optical axis of the visible camera as the central axis. The simulation results show that the system solves the fuzzy problems of the equipment that are caused by glare, reflection of light and shadow, and the robot can observe details of the running status of electrical equipment. And the full coverage of the substation equipment inspection robot observation target is achieved, which ensures the safe operation of the substation equipment.

  19. A Novel Wide-Area Backup Protection Based on Fault Component Current Distribution and Improved Evidence Theory

    PubMed Central

    Zhang, Zhe; Kong, Xiangping; Yin, Xianggen; Yang, Zengli; Wang, Lijun

    2014-01-01

    In order to solve the problems of the existing wide-area backup protection (WABP) algorithms, the paper proposes a novel WABP algorithm based on the distribution characteristics of fault component current and improved Dempster/Shafer (D-S) evidence theory. When a fault occurs, slave substations transmit to master station the amplitudes of fault component currents of transmission lines which are the closest to fault element. Then master substation identifies suspicious faulty lines according to the distribution characteristics of fault component current. After that, the master substation will identify the actual faulty line with improved D-S evidence theory based on the action states of traditional protections and direction components of these suspicious faulty lines. The simulation examples based on IEEE 10-generator-39-bus system show that the proposed WABP algorithm has an excellent performance. The algorithm has low requirement of sampling synchronization, small wide-area communication flow, and high fault tolerance. PMID:25050399

  20. A Study on Effect of Concrete Foundations on Resistance and Surface Potentials of Gas Insulated Substation Grounding Systems

    NASA Astrophysics Data System (ADS)

    Rao, Mandava Mohana

    2017-10-01

    Ground resistance of high voltage substations must be as low as possible for safe grounding of their equipment both during normal and fault conditions. However, in gas insulated substations (GIS), even though resistance is low, it does not ensure the step and touch potentials of the grounding system within permissible levels. In the present study, an analytical model has been developed to calculate ground resistance, step and touch potentials of a grounding system used for GIS. Different models have been proposed for the evaluation of number of grounding rods to be inserted in to the ground. The effect of concrete foundations on above performance parameters has been analyzed by considering various fault currents, soil/earth resistivities and number of grounding rods. Finally, design optimization of GIS grounding system has been reported for fault currents in the order of 63 kA located in earth resistivity of 100Ω-m and above.

  1. On-rail solution for autonomous inspections in electrical substations

    NASA Astrophysics Data System (ADS)

    Silva, Bruno P. A.; Ferreira, Rafael A. M.; Gomes, Selson C.; Calado, Flavio A. R.; Andrade, Roberto M.; Porto, Matheus P.

    2018-05-01

    This work presents an alternative solution for autonomous inspections in electrical substations. The autonomous system is a robot that moves on rails, collects infrared and visible images of selected targets, also processes the data and predicts the components lifetime. The robot moves on rails to overcome difficulties found in not paved substations commonly encountered in Brazil. We take advantage of using rails to convey the data by them, minimizing the electromagnetic interference, and at the same time transmitting electrical energy to feed the autonomous system. As part of the quality control process, we compared thermographic inspections made by the robot with inspections made by a trained thermographer using a scientific camera Flir® SC660. The results have shown that the robot achieved satisfactory results, identifying components and measuring temperature accurately. The embodied routine considers the weather changes along the day, providing a standard result of the components thermal response, also gives the uncertainty of temperature measurement, contributing to the quality in the decision making process.

  2. The Effects of Temperature on Political Violence: Global Evidence at the Subnational Level

    PubMed Central

    Bollfrass, Alexander; Shaver, Andrew

    2015-01-01

    A number of studies have demonstrated an empirical relationship between higher ambient temperatures and substate violence, which have been extrapolated to make predictions about the security implications of climate change. This literature rests on the untested assumption that the mechanism behind the temperature-conflict link is that disruption of agricultural production provokes local violence. Using a subnational-level dataset, this paper demonstrates that the relationship: (1) obtains globally, (2) exists at the substate level — provinces that experience positive temperature deviations see increased conflict; and (3) occurs even in regions without significant agricultural production. Diminished local farm output resulting from elevated temperatures is unlikely to account for the entire increase in substate violence. The findings encourage future research to identify additional mechanisms, including the possibility that a substantial portion of the variation is brought about by the well-documented direct effects of temperature on individuals' propensity for violence or through macroeconomic mechanisms such as food price shocks. PMID:25992616

  3. Hiding Critical Targets in Smart Grid Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bao, Wei; Li, Qinghua

    With the integration of advanced communication technologies, the power grid is expected to greatly enhance efficiency and reliability of future power systems. However, since most electrical devices in power grid substations are connected via communication networks, cyber security of these communication networks becomes a critical issue. Real-World incidents such as Stuxnet have shown the feasibility of compromising a device in the power grid network to further launch more sophisticated attacks. To deal with security attacks of this spirit, this paper aims to hide critical targets from compromised internal nodes and hence protect them from further attacks launched by those compromisedmore » nodes. In particular, we consider substation networks and propose to add carefully-controlled dummy traffic to a substation network to make critical target nodes indistinguishable from other nodes in network traffic patterns. This paper describes the design and evaluation of such a scheme. Evaluations show that the scheme can effectively protect critical nodes with acceptable communication cost.« less

  4. Grizzly Substation Fiber Optics : Environmental Assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1998-02-01

    This notice announces BPA`s decision to construct, operate, and maintain the Grizzly Substation Fiber Optic Project (Project). This Project is part of a continuing effort by BPA to complete a regionwide upgrade of its existing telecommunications system. The US Forest Service and BPA jointly prepared the Grizzly Substation Fiber Optic Project Environmental Assessment (EA) (DOE/EA-1241) evaluating the potential environmental impacts of the Proposed Action, the Underground Installation Alternative, and the No Action Alternative. Based on the analysis in the EA, the US Forest Service and BPA have determined that the Proposed Action is not a major Federal action significantly affectingmore » the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an Environmental Impact Statement (EIS) is not required and BPA is issuing this FONSI. The US Forest Service has separately issued a FONSI and Decision Notice authorizing BPA to construct, operate, and maintain the Project within the Crooked River National Grassland (Grassland).« less

  5. A health examination of railway high-voltage substation workers exposed to ELF electromagnetic fields.

    PubMed

    Baroncelli, P; Battisti, S; Checcucci, A; Comba, P; Grandolfo, M; Serio, A; Vecchia, P

    1986-01-01

    This is a cross-sectional survey on the health conditions of railways workers active in 258 interconnection and conversion substations all over Italy. Measurements performed in both kinds of substations operating at 220 kV have shown that maximum levels of the electric field strength and of the magnetic flux density at 50 Hz are of the order of 5 kV/m and 15 microT, respectively. Three subject groups, differently exposed (1, 10, 20 h/week), and an unexposed control group, for a total number of 627 workers, constitute the population at study. All subjects underwent a general medical examination, laboratory investigations, and a series of selected examinations relative to three systems (nervous, cardiovascular, and haematopoietic) considered at higher risk. No differences have been found between the exposed and the control groups. It is concluded that workers exposed to ELF electromagnetic fields of moderate strength do not show the presence of clear effects on their state of health.

  6. Monitoring changes in stream bottom sediments and benthic invertebrates.

    DOT National Transportation Integrated Search

    1981-01-01

    The study was conducted to determine whether the analysis of stream bottom sediments could be used to assess sediment pollution generated by highway construction. Most of the work completed to date has involved testing and refining methods for the co...

  7. Assessment of the risk of failure of high voltage substations due to environmental conditions and pollution on insulators.

    PubMed

    Castillo Sierra, Rafael; Oviedo-Trespalacios, Oscar; Candelo, John E; Soto, Jose D

    2015-07-01

    Pollution on electrical insulators is one of the greatest causes of failure of substations subjected to high levels of salinity and environmental pollution. Considering leakage current as the main indicator of pollution on insulators, this paper focuses on establishing the effect of the environmental conditions on the risk of failure due to pollution on insulators and determining the significant change in the magnitude of the pollution on the insulators during dry and humid periods. Hierarchical segmentation analysis was used to establish the effect of environmental conditions on the risk of failure due to pollution on insulators. The Kruskal-Wallis test was utilized to determine the significant changes in the magnitude of the pollution due to climate periods. An important result was the discovery that leakage current was more common on insulators during dry periods than humid ones. There was also a higher risk of failure due to pollution during dry periods. During the humid period, various temperatures and wind directions produced a small change in the risk of failure. As a technical result, operators of electrical substations can now identify the cause of an increase in risk of failure due to pollution in the area. The research provides a contribution towards the behaviour of the leakage current under conditions similar to those of the Colombian Caribbean coast and how they affect the risk of failure of the substation due to pollution.

  8. Energy landscape of LeuT from molecular simulations

    NASA Astrophysics Data System (ADS)

    Gur, Mert; Zomot, Elia; Cheng, Mary Hongying; Bahar, Ivet

    2015-12-01

    The bacterial sodium-coupled leucine transporter (LeuT) has been broadly used as a structural model for understanding the structure-dynamics-function of mammalian neurotransmitter transporters as well as other solute carriers that share the same fold (LeuT fold), as the first member of the family crystallographically resolved in multiple states: outward-facing open, outward-facing occluded, and inward-facing open. Yet, a complete picture of the energy landscape of (sub)states visited along the LeuT transport cycle has been elusive. In an attempt to visualize the conformational spectrum of LeuT, we performed extensive simulations of LeuT dimer dynamics in the presence of substrate (Ala or Leu) and co-transported Na+ ions, in explicit membrane and water. We used both conventional molecular dynamics (MD) simulations (with Anton supercomputing machine) and a recently introduced method, collective MD, that takes advantage of collective modes of motions predicted by the anisotropic network model. Free energy landscapes constructed based on ˜40 μs trajectories reveal multiple substates occluded to the extracellular (EC) and/or intracellular (IC) media, varying in the levels of exposure of LeuT to EC or IC vestibules. The IC-facing transmembrane (TM) helical segment TM1a shows an opening, albeit to a smaller extent and in a slightly different direction than that observed in the inward-facing open crystal structure. The study provides insights into the spectrum of conformational substates and paths accessible to LeuT and highlights the differences between Ala- and Leu-bound substates.

  9. Energy landscape of LeuT from molecular simulations.

    PubMed

    Gur, Mert; Zomot, Elia; Cheng, Mary Hongying; Bahar, Ivet

    2015-12-28

    The bacterial sodium-coupled leucine transporter (LeuT) has been broadly used as a structural model for understanding the structure-dynamics-function of mammalian neurotransmitter transporters as well as other solute carriers that share the same fold (LeuT fold), as the first member of the family crystallographically resolved in multiple states: outward-facing open, outward-facing occluded, and inward-facing open. Yet, a complete picture of the energy landscape of (sub)states visited along the LeuT transport cycle has been elusive. In an attempt to visualize the conformational spectrum of LeuT, we performed extensive simulations of LeuT dimer dynamics in the presence of substrate (Ala or Leu) and co-transported Na(+) ions, in explicit membrane and water. We used both conventional molecular dynamics (MD) simulations (with Anton supercomputing machine) and a recently introduced method, collective MD, that takes advantage of collective modes of motions predicted by the anisotropic network model. Free energy landscapes constructed based on ∼40 μs trajectories reveal multiple substates occluded to the extracellular (EC) and/or intracellular (IC) media, varying in the levels of exposure of LeuT to EC or IC vestibules. The IC-facing transmembrane (TM) helical segment TM1a shows an opening, albeit to a smaller extent and in a slightly different direction than that observed in the inward-facing open crystal structure. The study provides insights into the spectrum of conformational substates and paths accessible to LeuT and highlights the differences between Ala- and Leu-bound substates.

  10. Energy landscape of LeuT from molecular simulations

    PubMed Central

    Gur, Mert; Zomot, Elia; Cheng, Mary Hongying; Bahar, Ivet

    2015-01-01

    The bacterial sodium-coupled leucine transporter (LeuT) has been broadly used as a structural model for understanding the structure-dynamics-function of mammalian neurotransmitter transporters as well as other solute carriers that share the same fold (LeuT fold), as the first member of the family crystallographically resolved in multiple states: outward-facing open, outward-facing occluded, and inward-facing open. Yet, a complete picture of the energy landscape of (sub)states visited along the LeuT transport cycle has been elusive. In an attempt to visualize the conformational spectrum of LeuT, we performed extensive simulations of LeuT dimer dynamics in the presence of substrate (Ala or Leu) and co-transported Na+ ions, in explicit membrane and water. We used both conventional molecular dynamics (MD) simulations (with Anton supercomputing machine) and a recently introduced method, collective MD, that takes advantage of collective modes of motions predicted by the anisotropic network model. Free energy landscapes constructed based on ∼40 μs trajectories reveal multiple substates occluded to the extracellular (EC) and/or intracellular (IC) media, varying in the levels of exposure of LeuT to EC or IC vestibules. The IC-facing transmembrane (TM) helical segment TM1a shows an opening, albeit to a smaller extent and in a slightly different direction than that observed in the inward-facing open crystal structure. The study provides insights into the spectrum of conformational substates and paths accessible to LeuT and highlights the differences between Ala- and Leu-bound substates. PMID:26723619

  11. A quick method for AlCu interconnect electromigration performance predicting and monitoring

    NASA Astrophysics Data System (ADS)

    Zhang, Wenjie; Yi, Leeward; Tao, Kai; Ma, Yue; Chang, Pingyi; Mao, Duli; Wu, Jin; Zou, S. C.

    2006-05-01

    The film properties and microstructures of (bottom)Si/SiO2/Ti(top) and (bottom)Si/SiO2/Ti/TiN/AlCu(top) stacks deposited by different processes were characterized. The resistivities of thin Ti films and the reflectivities of AlCu alloy films were found to correlate with the microstructure as well as the mean time to failure (MTTF) in the electromigration (EM) test. A quick-turn monitor for AlCu interconnect reliability in the semiconductor manufacturing industry was established.

  12. High-precision multi-node clock network distribution.

    PubMed

    Chen, Xing; Cui, Yifan; Lu, Xing; Ci, Cheng; Zhang, Xuesong; Liu, Bo; Wu, Hong; Tang, Tingsong; Shi, Kebin; Zhang, Zhigang

    2017-10-01

    A high precision multi-node clock network for multiple users was built following the precise frequency transmission and time synchronization of 120 km fiber. The network topology adopts a simple star-shaped network structure. The clock signal of a hydrogen maser (synchronized with UTC) was recovered from a 120 km telecommunication fiber link and then was distributed to 4 sub-stations. The fractional frequency instability of all substations is in the level of 10 -15 in a second and the clock offset instability is in sub-ps in root-mean-square average.

  13. Combining split-beam and dual-frequency identification sonars to estimate abundance of anadromous fishes in the Roanoke River, North Carolina

    USGS Publications Warehouse

    Hughes, Jacob B.; Hightower, Joseph E.

    2015-01-01

    Riverine hydroacoustic techniques are an effective method for evaluating abundance of upstream migrating anadromous fishes. To use these methods in the Roanoke River, North Carolina, at a wide site with uneven bottom topography, we used a combination of split-beam sonar and dual-frequency identification sonar (DIDSON) deployments. We aimed a split-beam sonar horizontally to monitor midchannel and near-bottom zones continuously over the 3-month spring monitoring periods in 2010 and 2011. The DIDSON was rotated between seven cross-channel locations (using a vertical aim) and nearshore regions (using horizontal aims). Vertical deployment addressed blind spots in split-beam coverage along the bottom and provided reliable information about the cross-channel and vertical distributions of upstream migrants. Using a Bayesian framework, we modeled sonar counts within four cross-channel strata and apportioned counts by species using species proportions from boat electrofishing and gill netting. Modeled estimates (95% credible intervals [CIs]) of total upstream migrants in 2010 and 2011 were 2.5 million (95% CI, 2.4–2.6 million) and 3.6 million (95% CI, 3.4–3.9 million), respectively. Results indicated that upstream migrants are extremely shore- and bottom-oriented, suggesting nearshore DIDSON monitoring improved the accuracy and precision of our estimates. This monitoring protocol and model may be widely applicable to river systems regardless of their cross-sectional width or profile.

  14. Monitoring of the Bonnet Carre Spillway Bridge during extreme overload.

    DOT National Transportation Integrated Search

    2003-10-01

    This report concerns the monitoring of a portion of the Bonnet Carr Spillway Bridge during an extreme overload. On Tuesday, November 5, 2002, Tulane University was requested to monitor strain at the bottom flange of two adjacent prestressed girders...

  15. Leukaemia and residence near electricity transmission equipment: a case-control study.

    PubMed Central

    Coleman, M. P.; Bell, C. M.; Taylor, H. L.; Primic-Zakelj, M.

    1989-01-01

    A population-based case-control study of leukaemia and residential proximity to electricity supply equipment has been carried out in south-east England. A total of 771 leukaemias was studied, matched for age, sex, year of diagnosis and district of residence to 1,432 controls registered with a solid tumour excluding lymphoma; 231 general population controls aged 18 and over from one part of the study area were also used. The potential for residential exposure to power frequency magnetic fields from power-lines and transformer substations was assessed indirectly from the distance, type and loading of the equipment near each subject's residence. Only 0.6% of subjects lived within 100 m of an overhead power-line, and the risk of leukaemia relative to cancer controls for residence within 100 m was 1.45 (95% confidence interval (CI) 0.54-3.88); within 50 m the relative risk was 2.0 but with a wider confidence interval (95% CI 0.4-9.0). Over 40% of subjects lived within 100 m of a substation, for which the relative risk of leukaemia was 0.99. Residence within 25 m carried a risk of 1.3 (95% CI 0.8-2.0). Weighted exposure indices incorporating measures of the current load carried by the substations did not materially alter these risks estimates. For persons aged less than 18 the relative risk of leukaemia from residence within 50 m of a substation was higher than in adults (PR = 1.5, 95% CI 0.7-3.4). PMID:2486298

  16. Event Detection and Sub-state Discovery from Bio-molecular Simulations Using Higher-Order Statistics: Application To Enzyme Adenylate Kinase

    PubMed Central

    Ramanathan, Arvind; Savol, Andrej J.; Agarwal, Pratul K.; Chennubhotla, Chakra S.

    2012-01-01

    Biomolecular simulations at milli-second and longer timescales can provide vital insights into functional mechanisms. Since post-simulation analyses of such large trajectory data-sets can be a limiting factor in obtaining biological insights, there is an emerging need to identify key dynamical events and relating these events to the biological function online, that is, as simulations are progressing. Recently, we have introduced a novel computational technique, quasi-anharmonic analysis (QAA) (PLoS One 6(1): e15827), for partitioning the conformational landscape into a hierarchy of functionally relevant sub-states. The unique capabilities of QAA are enabled by exploiting anharmonicity in the form of fourth-order statistics for characterizing atomic fluctuations. In this paper, we extend QAA for analyzing long time-scale simulations online. In particular, we present HOST4MD - a higher-order statistical toolbox for molecular dynamics simulations, which (1) identifies key dynamical events as simulations are in progress, (2) explores potential sub-states and (3) identifies conformational transitions that enable the protein to access those sub-states. We demonstrate HOST4MD on micro-second time-scale simulations of the enzyme adenylate kinase in its apo state. HOST4MD identifies several conformational events in these simulations, revealing how the intrinsic coupling between the three sub-domains (LID, CORE and NMP) changes during the simulations. Further, it also identifies an inherent asymmetry in the opening/closing of the two binding sites. We anticipate HOST4MD will provide a powerful and extensible framework for detecting biophysically relevant conformational coordinates from long time-scale simulations. PMID:22733562

  17. Electrical distribution studies for the 200 Area tank farms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisler, J.B.

    1994-08-26

    This is an engineering study providing reliability numbers for various design configurations as well as computer analyses (Captor/Dapper) of the existing distribution system to the 480V side of the unit substations. The objective of the study was to assure the adequacy of the existing electrical system components from the connection at the high voltage supply point through the transformation and distribution equipment to the point where it is reduced to its useful voltage level. It also was to evaluate the reasonableness of proposed solutions of identified deficiencies and recommendations of possible alternate solutions. The electrical utilities are normally considered themore » most vital of the utility systems on a site because all other utility systems depend on electrical power. The system accepts electric power from the external sources, reduces it to a lower voltage, and distributes it to end-use points throughout the site. By classic definition, all utility systems extend to a point 5 feet from the facility perimeter. An exception is made to this definition for the electric utilities at this site. The electrical Utility System ends at the low voltage section of the unit substation, which reduces the voltage from 13.8 kV to 2,400, 480, 277/480 or 120/208 volts. These transformers are located at various distances from existing facilities. The adequacy of the distribution system which transports the power from the main substation to the individual area substations and other load centers is evaluated and factored into the impact of the future load forecast.« less

  18. Molecular dynamics of conformational substates for a simplified protein model

    NASA Astrophysics Data System (ADS)

    Grubmüller, Helmut; Tavan, Paul

    1994-09-01

    Extended molecular dynamics simulations covering a total of 0.232 μs have been carried out on a simplified protein model. Despite its simplified structure, that model exhibits properties similar to those of more realistic protein models. In particular, the model was found to undergo transitions between conformational substates at a time scale of several hundred picoseconds. The computed trajectories turned out to be sufficiently long as to permit a statistical analysis of that conformational dynamics. To check whether effective descriptions neglecting memory effects can reproduce the observed conformational dynamics, two stochastic models were studied. A one-dimensional Langevin effective potential model derived by elimination of subpicosecond dynamical processes could not describe the observed conformational transition rates. In contrast, a simple Markov model describing the transitions between but neglecting dynamical processes within conformational substates reproduced the observed distribution of first passage times. These findings suggest, that protein dynamics generally does not exhibit memory effects at time scales above a few hundred picoseconds, but confirms the existence of memory effects at a picosecond time scale.

  19. Casper to Dave Johnston 230-kV Transmission Line Project: Environmental assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1986-01-01

    Western proposes to reconstruct the existing Casper-Glendo North 115-kV Transmission Line to 230-kV between a point 1.1 miles northeast of the Pacific Power and Light (Pacific) Casper Substation and the Dave Johnston (DJ) Powerplant near Glenrock, Wyoming. As part of the proposed action, Western proposes to remove the portion of the existing Casper-Glendo South 115-kV Transmission Line between Western's Casper Substation and the intersection with the Casper-Glendo North Transmission Line, about 15 miles east of Casper. The removed portion of the Casper-Glendo North Transmission Line would be rebuilt on steel, single-shaft, structures. The section between the point northeast of themore » Pacific Substation and the intersection with the Casper-Glendo South Transmission Line would be double circuit (230-kV/115-kV). At the intersection of the north and south lines, the new 115-kV section would be tied to the remaining portion of the Casper-Glendo South Line to complete the 115-kV Casper-Glendo circuit. 52 refs.,12 figs., 14 tabs.« less

  20. Historical precedence and technical requirements of biological weapons use : a threat assessment.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Estes, Daniel P.; Vogel, Kathleen Margaret; Gaudioso, Jennifer Marie

    2004-05-01

    The threat from biological weapons is assessed through both a comparative historical analysis of the patterns of biological weapons use and an assessment of the technological hurdles to proliferation and use that must be overcome. The history of biological weapons is studied to learn how agents have been acquired and what types of states and substate actors have used agents. Substate actors have generally been more willing than states to use pathogens and toxins and they have focused on those agents that are more readily available. There has been an increasing trend of bioterrorism incidents over the past century, butmore » states and substate actors have struggled with one or more of the necessary technological steps. These steps include acquisition of a suitable agent, production of an appropriate quantity and form, and effective deployment. The technological hurdles associated with the steps present a real barrier to producing a high consequence event. However, the ever increasing technological sophistication of society continually lowers the barriers, resulting in a low but increasing probability of a high consequence bioterrorism event.« less

  1. Intercomparison of magnetic field measurements near MV/LV transformer substations: methodological planning and results.

    PubMed

    Violanti, S; Fraschetta, M; Adda, S; Caputo, E

    2009-12-01

    Within the framework of Environmental Agencies system's activities, coordinated by ISPRA (superior institute for environmental protection and research), a comparison among measurements was designed and accomplished, in order to go into depth on the matter of measurement problems and to evaluate magnetic field at power frequencies. These measurements have been taken near medium voltage /low voltage transformer substation. This project was developed with the contribution of several experts who belong to different Regional Agencies. In three of these regions, substations having specific international standard characteristics were chosen; then a measurement and data analysis protocol was arranged. Data analysis showed a good level of coherence among results obtained by different laboratories. However, a range of problems emerged, either during the protocol predisposition and definition of the data analysis procedure or during the execution of measures and data reprocessing, because of the spatial and temporal variability of magnetic field. These problems represent elements of particular interest in determining a correct measurement methodology, whose purpose is the comparison with limits of exposure, attention values and quality targets.

  2. DReAM: Demand Response Architecture for Multi-level District Heating and Cooling Networks

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bhattacharya, Saptarshi; Chandan, Vikas; Arya, Vijay

    In this paper, we exploit the inherent hierarchy of heat exchangers in District Heating and Cooling (DHC) networks and propose DReAM, a novel Demand Response (DR) architecture for Multi-level DHC networks. DReAM serves to economize system operation while still respecting comfort requirements of individual consumers. Contrary to many present day DR schemes that work on a consumer level granularity, DReAM works at a level of hierarchy above buildings, i.e. substations that supply heat to a group of buildings. This improves the overall DR scalability and reduce the computational complexity. In the first step of the proposed approach, mathematical models ofmore » individual substations and their downstream networks are abstracted into appropriately constructed low-complexity structural forms. In the second step, this abstracted information is employed by the utility to perform DR optimization that determines the optimal heat inflow to individual substations rather than buildings, in order to achieve the targeted objectives across the network. We validate the proposed DReAM framework through experimental results under different scenarios on a test network.« less

  3. Using National Coastal Condition Assessment Underwater Video to Investigate Nearshore Substrate Type

    EPA Science Inventory

    A comprehensive method for describing bottom types in Great Lakes nearshore regions (<30 m deep and <5 km from shore) would enhance our ability to target monitoring efforts. Dredges are ineffective at sampling hard bottoms (bedrock/boulder/cobble) and other habitat features. We a...

  4. Apparatus for inspecting fuel elements

    DOEpatents

    Oakley, David J.; Groves, Oliver J.; Kaiser, Bruce J.

    1986-01-01

    Disclosed is an alpha monitor usable in an automated nuclear fuel pin loading and processing unit. Fuel pins or other elongated pins are fed laterally into the alpha monitor in a singular fashion and are translated by a first roller assembly into a weld flare machining and decontamination substation not forming a part of the invention. Pins return and are lifted upwardly and transferred across to a combined pin lifting and electrode operating means which lifts the pins upwardly into a clamshell electrode assembly which is spread open by a combined pin lifting and electrode operating means. Once inserted the clamshell type electrode arrangement closes around the fuel pins so that inspection can occur. Fuel pins are inspected by charging electrodes to a negative potential and measuring the change in charge occurring when positively charged alpha particles strike the negatively charged electrodes. After inspection, the fuel pins are lowered by the pin lifting and electrode operating means into a second roller assembly which longitudinally conveys approved pins from the airtight enclosure in which the alpha monitor is mounted. If the fuel pins are rejected then they are moved laterally by a second transfer means and onto another system for further processing.

  5. Apparatus for inspecting fuel elements

    DOEpatents

    Kaiser, B.J.; Oakley, D.J.; Groves, O.J.

    1984-12-21

    This disclosure describes an alpha monitor usable in an automated nuclear fuel pin loading and processing unit. Fuel pins or other elongated pins are fed laterally into the alpha monitor in a singular fashion and are translated by a first roller assembly into a weld flare machining and decontamination substation not forming a part of the invention. Pins return and are lifted upwardly and transferred across to a combined pin lifting and electrode operating means which lifts the pins upwardly into a clamshell electrode assembly which is spread open by a combined pin lifting and electrode operating means. Once inserted the clamshell type electrode arrangement closes around the fuel pins so that inspection can occur. Fuel pins are inspected by charging electrodes to a negative potential and measuring the change in charge occurring when positively charged alpha particles strike the negatively charged electrodes. After inspection, the fuel pins are lowered by the pin lifting and electrode operating means into a second roller assembly which longitudinally conveys approved pins from the airtight enclosure in which the alpha monitor is mounted. If the fuel pins are rejected then they are moved laterally by a second transfer means and onto another system for further processing.

  6. Functional Sub-states by High-pressure Macromolecular Crystallography.

    PubMed

    Dhaussy, Anne-Claire; Girard, Eric

    2015-01-01

    At the molecular level, high-pressure perturbation is of particular interest for biological studies as it allows trapping conformational substates. Moreover, within the context of high-pressure adaptation of deep-sea organisms, it allows to decipher the molecular determinants of piezophily. To provide an accurate description of structural changes produced by pressure in a macromolecular system, developments have been made to adapt macromolecular crystallography to high-pressure studies. The present chapter is an overview of results obtained so far using high-pressure macromolecular techniques, from nucleic acids to virus capsid through monomeric as well as multimeric proteins.

  7. The results of systems tests of the 500 kV busbar controllable shunting reactor in the Tavricheskaya substation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusev, S. I.; Karpov, V. N.; Kiselev, A. N.

    2009-09-15

    The results of systems tests of the 500 kV busbar magnetization-controllable shunting reactor (CSR), set up in the Tavricheskaya substation, including measurements of the quality of the electric power, the harmonic composition of the network currents of the reactor for different values of the reactive power consumed, the determination of the regulating characteristics of the reactor, the speed of response of the shunting reactor in the current and voltage stabilization modes, and also the operation of the reactor under dynamic conditions for different perturbations, are presented. The results obtained are analyzed.

  8. Development of a GPS buoy system for monitoring tsunami, sea waves, ocean bottom crustal deformation and atmospheric water vapor

    NASA Astrophysics Data System (ADS)

    Kato, Teruyuki; Terada, Yukihiro; Nagai, Toshihiko; Koshimura, Shun'ichi

    2010-05-01

    We have developed a GPS buoy system for monitoring tsunami for over 12 years. The idea was that a buoy equipped with a GPS antenna and placed offshore may be an effective way of monitoring tsunami before its arrival to the coast and to give warning to the coastal residents. The key technology for the system is real-time kinematic (RTK) GPS technology. We have successfully developed the system; we have detected tsunamis of about 10cm in height for three large earthquakes, namely, the 23 June 2001 Peru earthquake (Mw8.4), the 26 September 2003 Tokachi earthquake (Mw8.3) and the 5 September 2004 earthquake (Mw7.4). The developed GPS buoy system is also capable of monitoring sea waves that are mainly caused by winds. Only the difference between tsunami and sea waves is their frequency range and can be segregated each other by a simple filtering technique. Given the success of GPS buoy experiments, the system has been adopted as a part of the Nationwide Ocean Wave information system for Port and HArborS (NOWPHAS) by the Ministry of Land, Infrastructure, Transport and Tourism of Japan. They have established more than eight GPS buoys along the Japanese coasts and the system has been operated by the Port and Airport Research Institute. As a future scope, we are now planning to implement some other additional facilities for the GPS buoy system. The first application is a so-called GPS/Acoustic system for monitoring ocean bottom crustal deformation. The system requires acoustic waves to detect ocean bottom reference position, which is the geometrical center of an array of transponders, by measuring distances between a position at the sea surface (vessel) and ocean bottom equipments to return the received sonic wave. The position of the vessel is measured using GPS. The system was first proposed by a research group at the Scripps Institution of Oceanography in early 1980's. The system was extensively developed by Japanese researchers and is now capable of detecting ocean bottom positions with a few centimeters in accuracy. The system is now operational for more than ten sites along the Japanese coasts. Currently, however, the measurements are not continuous but have been done once to several times a year using a boat. If a GPS and acoustic system is placed on a buoy, ocean bottom position could be monitored in near real-time and continuous manner. This will allow us to monitor more detailed and short term crustal deformations at the sea bottom. Another application plan is for an atmospheric research. Previous researchers have shown that GPS is capable of measuring atmospheric water vapor through estimating tropospheric zenith delay measurements of GPS at the sea surface. Information of water vapor content and its temporal variation over sea surface will much contribute to weather forecast on land which has mostly been conducted only by land observations. Considering that the atmospheric mass moves from west to east in general in and around Japanese islands, information of water vapor together with other atmospheric data from an array of GPS buoy placed in the west of Japanese Islands, will much improve weather forecast. We try to examine if this is also feasible. As a conclusion of a series of GPS buoy experiments, we could assert that GPS buoy system will be a powerful tool to monitor ocean surface and much contribute to provide safe and secure life of people.

  9. High-resolution synchrotron-based Fourier transform spectroscopy of [image omitted] in the 120-350 cm-1 far-infrared region

    NASA Astrophysics Data System (ADS)

    Moruzzi, G.; Murphy, R. J.; Lees, R. M.; Predoi-Cross, A.; Billinghurst, B. E.

    2010-09-01

    The Fourier transform spectrum of the ? isotopologue of methanol has been recorded in the 120-350 cm-1 far-infrared region at a resolution of 0.00096 cm-1 using synchrotron source radiation at the Canadian Light Source. The study, motivated by astrophysical applications, is aimed at generating a sufficiently accurate set of energy level term values for the ground vibrational state to allow prediction of the centres of the quadrupole hyperfine multiplets for astronomically observable sub-millimetre transitions to within an uncertainty of a few MHz. To expedite transition identification, a new function was added to the Ritz program in which predicted spectral line positions were generated by an adjustable interpolation between the known assignments for the ? and ? isotopologues. By displaying the predictions along with the experimental spectrum on the computer monitor and adjusting the predictions to match observed features, rapid assignment of numerous ? sub-bands was possible. The least squares function of the Ritz program was then used to generate term values for the identified levels. For each torsion-K-rotation substate, the term values were fitted to a Taylor-series expansion in powers of J(J + 1) to determine the substate origin energy and effective B-value. In this first phase of the study we did not attempt a full global fit to the assigned transitions, but instead fitted the sub-band J-independent origins to a restricted Hamiltonian containing the principal torsional and K-dependent terms. These included structural and torsional potential parameters plus quartic distortional and torsion-rotation interaction terms.

  10. 40 CFR 146.68 - Testing and monitoring requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...; or (iii) Using an alternative method approved by the Director. (3) If a corrosion monitoring program... been a well workover; (2) The bottom-hole cement shall be tested by means of an approved radioactive...

  11. ESTIMATING RISK TO CALIFORNIA ENERGY INFRASTRUCTURE FROM PROJECTED CLIMATE CHANGE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sathaye, Jayant; Dale, Larry; Larsen, Peter

    2011-06-22

    This report outlines the results of a study of the impact of climate change on the energy infrastructure of California and the San Francisco Bay region, including impacts on power plant generation; transmission line and substation capacity during heat spells; wildfires near transmission lines; sea level encroachment upon power plants, substations, and natural gas facilities; and peak electrical demand. Some end-of-century impacts were projected:Expected warming will decrease gas-fired generator efficiency. The maximum statewide coincident loss is projected at 10.3 gigawatts (with current power plant infrastructure and population), an increase of 6.2 percent over current temperature-induced losses. By the end ofmore » the century, electricity demand for almost all summer days is expected to exceed the current ninetieth percentile per-capita peak load. As much as 21 percent growth is expected in ninetieth percentile peak demand (per-capita, exclusive of population growth). When generator losses are included in the demand, the ninetieth percentile peaks may increase up to 25 percent. As the climate warms, California's peak supply capacity will need to grow faster than the population.Substation capacity is projected to decrease an average of 2.7 percent. A 5C (9F) air temperature increase (the average increase predicted for hot days in August) will diminish the capacity of a fully-loaded transmission line by an average of 7.5 percent.The potential exposure of transmission lines to wildfire is expected to increase with time. We have identified some lines whose probability of exposure to fire are expected to increase by as much as 40 percent. Up to 25 coastal power plants and 86 substations are at risk of flooding (or partial flooding) due to sea level rise.« less

  12. Event detection and sub-state discovery from biomolecular simulations using higher-order statistics: application to enzyme adenylate kinase.

    PubMed

    Ramanathan, Arvind; Savol, Andrej J; Agarwal, Pratul K; Chennubhotla, Chakra S

    2012-11-01

    Biomolecular simulations at millisecond and longer time-scales can provide vital insights into functional mechanisms. Because post-simulation analyses of such large trajectory datasets can be a limiting factor in obtaining biological insights, there is an emerging need to identify key dynamical events and relating these events to the biological function online, that is, as simulations are progressing. Recently, we have introduced a novel computational technique, quasi-anharmonic analysis (QAA) (Ramanathan et al., PLoS One 2011;6:e15827), for partitioning the conformational landscape into a hierarchy of functionally relevant sub-states. The unique capabilities of QAA are enabled by exploiting anharmonicity in the form of fourth-order statistics for characterizing atomic fluctuations. In this article, we extend QAA for analyzing long time-scale simulations online. In particular, we present HOST4MD--a higher-order statistical toolbox for molecular dynamics simulations, which (1) identifies key dynamical events as simulations are in progress, (2) explores potential sub-states, and (3) identifies conformational transitions that enable the protein to access those sub-states. We demonstrate HOST4MD on microsecond timescale simulations of the enzyme adenylate kinase in its apo state. HOST4MD identifies several conformational events in these simulations, revealing how the intrinsic coupling between the three subdomains (LID, CORE, and NMP) changes during the simulations. Further, it also identifies an inherent asymmetry in the opening/closing of the two binding sites. We anticipate that HOST4MD will provide a powerful and extensible framework for detecting biophysically relevant conformational coordinates from long time-scale simulations. Copyright © 2012 Wiley Periodicals, Inc.

  13. Conformational flexibility of arginine-82 as source for the heterogeneous and pH-dependent kinetics of the primary proton transfer step in the bacteriorhodopsin photocycle: An electrostatic model

    NASA Astrophysics Data System (ADS)

    Scharnagl, Christina; Fischer, Sighart F.

    1996-11-01

    We use equilibrium thermodynamic concepts to relate protein conformational and protonation substates and their pH-dependent population to kinetic schemes for the rise of the M intermediate in the photocycle of bacteriorhodopsin. Conformational flexibility of arginine R82 is described by a two-state model. The analysis accounts for the electrostatic coupling between its orientation and hydrogen ion titration and presents a structural basis for the linkage between the protonation states of the primary proton acceptor, aspartate D85, and the extracellular release group, glutamate E204. We find that the charge state of D85 is a significant determinant for the orientation of R82. The molecular model predicts the following: the primary proton transfer to D85 can be described by a kinetic scheme with two heterogeneous substates. They control the event with different activation parameters due to the reorientation of R82 away from the chromophore binding site. Their population depends on the external pH and the proton exchange equilibrium between the membrane buried residues and the bulk aqueous solvent. Proton transfer in the physiologic pH range is strongly activated and followed by the reorientation of R82 which shifts the equilibrium toward complete transfer. In the alkaline pH region a different mechanism operates, which involves the increased population of a substate with already reoriented R82 as a consequence of the deprotonation of E204, leading to accelerated proton transfer. Assuming full proton exchange equilibrium with the bulk water on the millisecond time scale leads to an increased population of substates which are non-productive for proton transfer.

  14. Cocaine use in the past year is associated with altitude of residence.

    PubMed

    Fiedler, Kristen K; Kim, Namkug; Kondo, Douglas G; Renshaw, Perry F

    2012-06-01

    Recently, increased rates of suicide in US counties at higher altitudes have been noted. Because of the documented association between cocaine use and suicide, we hypothesized that there would be a correlation between incidence of cocaine use and altitude of residence. Cocaine use data were obtained from the Substate Substance Abuse Estimates from the 1999-2001 National Surveys on Drug Use and Health. Data related to the percentages of people 12 years or older who used cocaine in the past year. Average elevation for US counties was calculated using the Shuttle Radar Topography Mission elevation data set, and subject region elevation was calculated by averaging the weighted elevations of each region's relevant counties. The correlation between elevation of a substate region and incidence of cocaine use in that region was calculated using Pearson correlation coefficients. A significant correlation exists between mean altitude of a substate region and incidence of cocaine use in that region (r = 0.34; P < 0.0001). Regression analysis controlling for age, sex, race, education level, income, unemployment, and population density was performed. Altitude remained a significant factor (P = 0.007), whereas male sex (P = 0.008) and possessing less than a college education (P < 0.0001) were also significant predictors of self-reported cocaine use in the past year. It is important to note that cocaine use was assessed in isolation of other drugs of abuse, an additional confounding variable. This study demonstrates a significant correlation between altitude of substate region of residence and incidence of cocaine use. It is possible that stress response due to hypoxia is responsible; however, this requires further investigation. However, because other substance use was not assessed, specificity of this association is unknown. In addition, this correlation may help explain the increased rate of suicide in areas of higher elevation.

  15. Trial of multidisciplinary observation at an expandable sub-marine cabled station "off-hatsushima island observatory" in sagami bay, Japan.

    PubMed

    Kasaya, Takafumi; Mitsuzawa, Kyohiko; Goto, Tada-Nori; Iwase, Ryoichi; Sayanagi, Keizo; Araki, Eiichiro; Asakawa, Kenichi; Mikada, Hitoshi; Watanabe, Tomoki; Takahashi, Ichiro; Nagao, Toshiyasu

    2009-01-01

    Sagami Bay is an active tectonic area in Japan. In 1993, a real-time deep sea floor observatory was deployed at 1,175 m depth about 7 km off Hatsushima Island, Sagami Bay to monitor seismic activities and other geophysical phenomena. Video cameras monitored biological activities associated with tectonic activities. The observation system was renovated completely in 2000. An ocean bottom electromagnetic meter (OBEM), an ocean bottom differential pressure gauge (DPG) system, and an ocean bottom gravity meter (OBG) were installed January 2005; operations began in February of that year. An earthquake (M5.4) in April 2006, generated a submarine landslide that reached the Hatsushima Observatory, moving some sensors. The video camera took movies of mudflows; OBEM and other sensors detected distinctive changes occurring with the mudflow. Although the DPG and OBG were recovered in January 2008, the OBEM continues to obtain data.

  16. Doubly Fed Induction Generator in an Offshore Wind Power Plant Operated at Rated V/Hz: Preprint

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muljadi, E.; Singh, M.; Gevorgian, V.

    2012-06-01

    This paper introduces the concept of constant Volt/Hz operation of offshore wind power plants. The deployment of offshore WPPs requires power transmission from the plant to the load center inland. Since this power transmission requires submarine cables, there is a need to use High-Voltage Direct Current transmission, which is economical for transmission distances longer than 50 kilometers. In the concept presented here, the onshore substation is operated at 60 Hz synced with the grid, and the offshore substation is operated at variable frequency and voltage, thus allowing the WPP to be operated at constant Volt/Hz.

  17. Analysis of the 60-Hz power system at KSC: The Orsino substation

    NASA Technical Reports Server (NTRS)

    Kalu, Alex O.

    1989-01-01

    An analysis of the Orsino Substation, a component (50 percent) of the 60-Hertz electric power system at the Kennedy Space Center, is presented. Presented here are separate single-line diagrams of the sixteen feeder circuits to permit easy access to information on the individual feeders for future planning. The load condition of each feeder and load break switch are presented and a heuristic reliability analysis of the system is performed. Information is given about the system fashion useful for decision making purposes. The beauty of it is in the simplified manner by which information about the system can be obtained.

  18. Study on the Transient Process of 500kV Substations Secondary Equipment

    NASA Astrophysics Data System (ADS)

    Li, Hongbo; Li, Pei; Zhang, Yanyan; Niu, Lin; Gao, Nannan; Si, Tailong; Guo, Jiadong; Xu, Min-min; Li, Guofeng; Guo, Liangfeng

    2017-05-01

    By analyzing on the reason of the lightning accident occur in the substation, the way of lightning incoming surge invading the secondary system is summarized. The interference source acts on the secondary system through various coupling paths. It mainly consists of four ways: the conductance coupling mode, the Capacitive Coupling Mode, the inductive coupling mode, The Radiation Interference Model. Then simulated the way with the program-ATP. At last, from the three aspects of low-voltage power supply system, the impact potential distribution of grounding grid, the secondary system and the computer system. The lightning protection measures is put forward.

  19. An Economic Analysis and Approach for Health Care Preparedness in a Substate Region.

    PubMed

    Stryckman, Benoit; Grace, Thomas L; Schwarz, Peter; Marcozzi, David

    2015-08-01

    To demonstrate the application of economics to health care preparedness by estimating the financial return on investment in a substate regional emergency response team and to develop a financial model aimed at sustaining community-level disaster readiness. Economic evaluation methods were applied to the experience of a regional Pennsylvania response capability. A cost-benefit analysis was performed by using information on funding of the response team and 17 real-world events the team responded to between 2008 and 2013. By use of the results of the cost-benefit analysis as well as information on the response team's catchment area, a risk-based insurance-like membership model was built. The cost-benefit analysis showed a positive return after 6 years of investment in the regional emergency response team. Financial modeling allowed for the calculation of premiums for 2 types of providers within the emergency response team's catchment area: hospitals and long-term care facilities. The analysis indicated that preparedness activities have a positive return on their investment in this substate region. By applying economic principles, communities can estimate their return on investment to make better business decisions in an effort to increase the sustainability of emergency preparedness programs at the regional level.

  20. Progress of gas-insulated transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Togawa, Y.; Ikeda, M.; Toda, K.

    The world`s first transformer was manufactured at Ganz in Hungary in 1885. Two years later in 1887 patents applications were made for about oil immersed transformers in the US. Since then, oil immersed types have predominated for medium- and large-capacity transformers, which are now giving way to gas insulated transformers in some areas. Behind such trends are plans to construct substations inside buildings or underground, because of the difficulty in acquiring land for substations in large cities where power demand is concentrated. Requirements are protection against accidents, compactness and overall economy. Total gas insulated substations combining GIS units and gasmore » insulated transformers these needs. Demand for gas insulated transformers has been increasing rapidly, particularly in Japan and Hong Kong. First, relatively small-capacity models below 20--30 MVA were put into practical use and today 275 kV, 300 MVa models are in use and 500kV, 1,500 MVA models are coming into use. Engineering is progressing very rapidly in these areas. This paper describes the design techniques and important maintenance techniques for the latest gas insulated transformers from 5,000 kVA to 300 MVA.« less

  1. IEA Wind Task 26: Offshore Wind Farm Baseline Documentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smart, Gavin; Smith, Aaron; Warner, Ethan

    This document has been produced to provide the definition and rationale for the Baseline Offshore Wind Farm established within IEA Wind Task 26--Cost of Wind Energy. The Baseline has been developed to provide a common starting point for country comparisons and sensitivity analysis on key offshore wind cost and value drivers. The baseline project reflects an approximate average of the characteristics of projects installed between 2012 and 2014, with the project life assumed to be 20 years. The baseline wind farm is located 40 kilometres (km) from construction and operations and maintenance (O&M) ports and from export cable landfall. Themore » wind farm consists of 100 4-megawatt (MW) wind turbines mounted on monopile foundations in an average water depth of 25 metres (m), connected by 33-kilovolt (kV) inter-array cables. The arrays are connected to a single offshore substation (33kV/220kV) mounted on a jacket foundation, with the substation connected via a single 220kV export cable to an onshore substation, 10km from landfall. The wind farm employs a port-based O&M strategy using crew-transfer vessels.« less

  2. Occupational exposure to electric and magnetic fields during work tasks at 110 kV substations in the Tampere region.

    PubMed

    Korpinen, Leena H; Pääkkönen, Rauno J

    2010-04-01

    The occupational exposure to electric and magnetic fields during various work tasks at seven 110 kV substations in Finland's Tampere region was studied. The aim was to investigate if the action values (10 kV/m for the E-field and 500 microT for the B-field) of the EU Directive 2004/40/EC were exceeded. Electric and magnetic fields were measured during the following work tasks: (1) walking or operating devices on the ground; (2) working from a service platform; (3) working around the power transformer on the ground or using a ladder; and (4) changing a bulb from a man hoist. In work task 2 "working from a service platform" the measured electric field (maximum value 16.6 kV/m) exceeded 10 kV/m in three cases. In the future it is important to study if the limit value (10 mA/m(2)) of Directive 2004/40/EC is exceeded at 110 kV substations. The occupational 500 microT action value of the magnetic flux density field (B-field) was not exceeded in any working situation.

  3. Ground-penetrating radar: A tool for monitoring bridge scour

    USGS Publications Warehouse

    Anderson, N.L.; Ismael, A.M.; Thitimakorn, T.

    2007-01-01

    Ground-penetrating radar (GPR) data were acquired across shallow streams and/or drainage ditches at 10 bridge sites in Missouri by maneuvering the antennae across the surface of the water and riverbank from the bridge deck, manually or by boat. The acquired two-dimensional and three-dimensional data sets accurately image the channel bottom, demonstrating that the GPR tool can be used to estimate and/or monitor water depths in shallow fluvial environments. The study results demonstrate that the GPR tool is a safe and effective tool for measuring and/or monitoring scour in proximity to bridges. The technique can be used to safely monitor scour at assigned time intervals during peak flood stages, thereby enabling owners to take preventative action prior to potential failure. The GPR tool can also be used to investigate depositional and erosional patterns over time, thereby elucidating these processes on a local scale. In certain instances, in-filled scour features can also be imaged and mapped. This information may be critically important to those engaged in bridge design. GPR has advantages over other tools commonly employed for monitoring bridge scour (reflection seismic profiling, echo sounding, and electrical conductivity probing). The tool doesn't need to be coupled to the water, can be moved rapidly across (or above) the surface of a stream, and provides an accurate depth-structure model of the channel bottom and subchannel bottom sediments. The GPR profiles can be extended across emerged sand bars or onto the shore.

  4. Power System Observation by using Synchronized Phasor Measurements as a Smart Device

    NASA Astrophysics Data System (ADS)

    Mitani, Yasunori

    Phasor Measurement Unit (PMU) is an apparatus which detects the absolute value of phase angle in sinusoidal signal. When more than two units are located distantly apart from each other, and they are synchronized with GPS signal which tells us the information on exact time, it becomes ready to get phase differences between two distant places. Thus, PMU with GPS receiver is applied to the monitoring of AC power system dynamics and usually installed at substations of transmission lines. The states of power network are uniquely determined by the active and reactive power and the magnitude and phase angle of voltage in each node. Among these values the phase angle had not been easily obtained until the scheme of time synchronism with GPS appeared. In this report, the history of GPS and PMU, and the current status of the applications in power systems in the world are presented. In Japan we are developing a power system monitoring system with PMUs installed at University's campuses with 100V outlets, which is called Campus WAMS. This report also introduces some results from the Campus WAMS briefly.

  5. High pressure liquid level monitor

    DOEpatents

    Bean, Vern E.; Long, Frederick G.

    1984-01-01

    A liquid level monitor for tracking the level of a coal slurry in a high-pressure vessel including a toroidal-shaped float with magnetically permeable bands thereon disposed within the vessel, two pairs of magnetic field generators and detectors disposed outside the vessel adjacent the top and bottom thereof and magnetically coupled to the magnetically permeable bands on the float, and signal processing circuitry for combining signals from the top and bottom detectors for generating a monotonically increasing analog control signal which is a function of liquid level. The control signal may be utilized to operate high-pressure control valves associated with processes in which the high-pressure vessel is used.

  6. A statistical model for monitoring shell disease in inshore lobster fisheries: A case study in Long Island Sound

    PubMed Central

    Chen, Yong

    2017-01-01

    The expansion of shell disease is an emerging threat to the inshore lobster fisheries in the northeastern United States. The development of models to improve the efficiency and precision of existing monitoring programs is advocated as an important step in mitigating its harmful effects. The objective of this study is to construct a statistical model that could enhance the existing monitoring effort through (1) identification of potential disease-associated abiotic and biotic factors, and (2) estimation of spatial variation in disease prevalence in the lobster fishery. A delta-generalized additive modeling (GAM) approach was applied using bottom trawl survey data collected from 2001–2013 in Long Island Sound, a tidal estuary between New York and Connecticut states. Spatial distribution of shell disease prevalence was found to be strongly influenced by the interactive effects of latitude and longitude, possibly indicative of a geographic origin of shell disease. Bottom temperature, bottom salinity, and depth were also important factors affecting the spatial variability in shell disease prevalence. The delta-GAM projected high disease prevalence in non-surveyed locations. Additionally, a potential spatial discrepancy was found between modeled disease hotspots and survey-based gravity centers of disease prevalence. This study provides a modeling framework to enhance research, monitoring and management of emerging and continuing marine disease threats. PMID:28196150

  7. Run-Curve Design for Energy Saving Operation in a Modern DC-Electrification

    NASA Astrophysics Data System (ADS)

    Koseki, Takafumi; Noda, Takashi

    Mechanical brakes are often used by electric trains. These brakes have a few problems like response speed, coefficient of friction, maintenance cost and so on. As a result, methods for actively using regenerative brakes are required. In this paper, we propose the useful pure electric braking, which would involve ordinary brakes by only regenerative brakes without any mechanical brakes at high speed. Benefits of our proposal include a DC-electrification system with regenerative substations that can return powers to the commercial power system and a train that can use the full regenerative braking force. We furthermore evaluate the effects on running time and energies saved by regenerative substations in the proposed method.

  8. A survey of industry practices regarding shielding of substations against direct lightning strokes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mousa, A.M.; Wehling, R.J.

    1993-01-01

    A survey of industry practices regarding shielding of substations against direct lightning strokes is presented and analyzed. The survey is based on responses from 114 companies including consultants and utilities both from within and from outside North America. The survey identifies the shielding design methods in use, the factors affecting the selection of a shielding method, the shielding design criteria and the governing factors, the performance of the different shielding methods and miscellaneous related aspects. The survey revealed a large number (35) of shielding failure incidents; 34 of which occurred in systems designed using either the fixed shielding angle methodmore » or Wagner's 1942 method.« less

  9. The effects of stream channelization on bottom dwelling organisms : phase 2 report : 1975 construction season.

    DOT National Transportation Integrated Search

    1976-01-01

    Three construction projects affecting streams are being monitored. On two of the projects, those affecting Meadow Run and Moores Creek, the streams are being monitored for flow, suspended solids, rainfall, and benthic populations. Construction has be...

  10. Status analysis of keyhole bottom in laser-MAG hybrid welding process.

    PubMed

    Wang, Lin; Gao, Xiangdong; Chen, Ziqin

    2018-01-08

    The keyhole status is a determining factor of weld quality in laser-metal active gas arc (MAG) hybrid welding process. For a better evaluation of the hybrid welding process, three different penetration welding experiments: partial penetration, normal penetration (or full penetration), and excessive penetration were conducted in this work. The instantaneous visual phenomena including metallic vapor, spatters and keyhole of bottom surface were used to evaluate the keyhole status by a double high-speed camera system. The Fourier transform was applied on the bottom weld pool image for removing the image noise around the keyhole, and then the bottom weld pool image was reconstructed through the inverse Fourier transform. Lastly, the keyhole bottom was extracted from the de-noised bottom weld pool image. By analyzing the visual features of the laser-MAG hybrid welding process, mechanism of the closed and opened keyhole bottom were revealed. The results show that the stable opened or closed status of keyhole bottom is directly affected by the MAG droplet transition in the normal penetration welding process, and the unstable opened or closed status of keyhole bottom would appear in excessive penetration welding and partial penetration welding. The analysis method proposed in this paper could be used to monitor the keyhole stability in laser-MAG hybrid welding process.

  11. Global motions exhibited by proteins in micro- to milliseconds simulations concur with anisotropic network model predictions

    NASA Astrophysics Data System (ADS)

    Gur, M.; Zomot, E.; Bahar, I.

    2013-09-01

    The Anton supercomputing technology recently developed for efficient molecular dynamics simulations permits us to examine micro- to milli-second events at full atomic resolution for proteins in explicit water and lipid bilayer. It also permits us to investigate to what extent the collective motions predicted by network models (that have found broad use in molecular biophysics) agree with those exhibited by full-atomic long simulations. The present study focuses on Anton trajectories generated for two systems: the bovine pancreatic trypsin inhibitor, and an archaeal aspartate transporter, GltPh. The former, a thoroughly studied system, helps benchmark the method of comparative analysis, and the latter provides new insights into the mechanism of function of glutamate transporters. The principal modes of motion derived from both simulations closely overlap with those predicted for each system by the anisotropic network model (ANM). Notably, the ANM modes define the collective mechanisms, or the pathways on conformational energy landscape, that underlie the passage between the crystal structure and substates visited in simulations. In particular, the lowest frequency ANM modes facilitate the conversion between the most probable substates, lending support to the view that easy access to functional substates is a robust determinant of evolutionarily selected native contact topology.

  12. Development of Protection and Control Unit for Distribution Substation

    NASA Astrophysics Data System (ADS)

    Iguchi, Fumiaki; Hayashi, Hideyuki; Takeuchi, Motohiro; Kido, Mitsuyasu; Kobayashi, Takashi; Yanaoka, Atsushi

    The Recently, electronics and IT technologies have been rapidly innovated and have been introduced to power system protection & control system to achieve high reliability, maintainability and more functionality. Concerning the distribution substation application, digital relays have been applied for more than 10 years. Because of a number of electronic devices used for it, product cost becomes higher. Also, products installed during the past high-growth period will be at the end of lifetime and will be replaced. Therefore, replacing market is expected to grow and the reduction of cost is demanded. Considering above mentioned background, second generation digital protection and control unit as a successor is designed to have following concepts. Functional integration based on advanced digital technologies, Ethernet LAN based indoor communication network, cost reduction and downsizing. Pondering above concepts, integration of protection and control function is adopted in contrary to the functional segregation applied to the previous system in order to achieve one-unit concept. Also the adoption of Ethernet LAN for inter-unit communication is objective. This report shows the development of second-generation digital relay for distribution substation, which is equipped with control function and Ethernet LAN by reducing the size of auxiliary transformer unit and the same size as previous product is realized.

  13. Measurement and Modeling of Personal Exposure to the Electric and Magnetic Fields in the Vicinity of High Voltage Power Lines.

    PubMed

    Tourab, Wafa; Babouri, Abdesselam

    2016-06-01

    This work presents an experimental and modeling study of the electromagnetic environment in the vicinity of a high voltage substation located in eastern Algeria (Annaba city) specified with a very high population density. The effects of electromagnetic fields emanating from the coupled multi-lines high voltage power systems (MLHV) on the health of the workers and people living in proximity of substations has been analyzed. Experimental Measurements for the Multi-lines power system proposed have been conducted in the free space under the high voltage lines. Field's intensities were measured using a referenced and calibrated electromagnetic field meter PMM8053B for the levels 0 m, 1 m, 1.5 m and 1.8 m witch present the sensitive's parts as organs and major functions (head, heart, pelvis and feet) of the human body. The measurement results were validated by numerical simulation using the finite element method and these results are compared with the limit values of the international standards. We project to set own national standards for exposure to electromagnetic fields, in order to achieve a regional database that will be at the disposal of partners concerned to ensure safety of people and mainly workers inside high voltage electrical substations.

  14. Heterogeneous Wireless Networks for Smart Grid Distribution Systems: Advantages and Limitations.

    PubMed

    Khalifa, Tarek; Abdrabou, Atef; Shaban, Khaled; Gaouda, A M

    2018-05-11

    Supporting a conventional power grid with advanced communication capabilities is a cornerstone to transferring it to a smart grid. A reliable communication infrastructure with a high throughput can lay the foundation towards the ultimate objective of a fully automated power grid with self-healing capabilities. In order to realize this objective, the communication infrastructure of a power distribution network needs to be extended to cover all substations including medium/low voltage ones. This shall enable information exchange among substations for a variety of system automation purposes with a low latency that suits time critical applications. This paper proposes the integration of two heterogeneous wireless technologies (such as WiFi and cellular 3G/4G) to provide reliable and fast communication among primary and secondary distribution substations. This integration allows the transmission of different data packets (not packet replicas) over two radio interfaces, making these interfaces act like a one data pipe. Thus, the paper investigates the applicability and effectiveness of employing heterogeneous wireless networks (HWNs) in achieving the desired reliability and timeliness requirements of future smart grids. We study the performance of HWNs in a realistic scenario under different data transfer loads and packet loss ratios. Our findings reveal that HWNs can be a viable data transfer option for smart grids.

  15. Heterogeneous Wireless Networks for Smart Grid Distribution Systems: Advantages and Limitations

    PubMed Central

    Khalifa, Tarek; Abdrabou, Atef; Gaouda, A. M.

    2018-01-01

    Supporting a conventional power grid with advanced communication capabilities is a cornerstone to transferring it to a smart grid. A reliable communication infrastructure with a high throughput can lay the foundation towards the ultimate objective of a fully automated power grid with self-healing capabilities. In order to realize this objective, the communication infrastructure of a power distribution network needs to be extended to cover all substations including medium/low voltage ones. This shall enable information exchange among substations for a variety of system automation purposes with a low latency that suits time critical applications. This paper proposes the integration of two heterogeneous wireless technologies (such as WiFi and cellular 3G/4G) to provide reliable and fast communication among primary and secondary distribution substations. This integration allows the transmission of different data packets (not packet replicas) over two radio interfaces, making these interfaces act like a one data pipe. Thus, the paper investigates the applicability and effectiveness of employing heterogeneous wireless networks (HWNs) in achieving the desired reliability and timeliness requirements of future smart grids. We study the performance of HWNs in a realistic scenario under different data transfer loads and packet loss ratios. Our findings reveal that HWNs can be a viable data transfer option for smart grids. PMID:29751633

  16. Draft Supplement to the Environmental Statement Fiscal Year 1975 Proposed Program : Facility Location Evaluation for San Juan Island Service : Decatur Land Line and East Lopez Island Substation Study Area 74-7.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration.

    1974-03-08

    Proposed construction of a 1.7-mile 34.5-kV double-circuit transmission line crossing Decatur Island from east to west. The new line would replace 0.7 of a mile of an existing BPA 24.5-kV line and would then parallel and existing 24.5-kV line for a distance of 1.0 mile. The proposal also requires the construction of a new substation to be located on the eastern side of Lopez Island, Washington. The additional easement required for the proposed transmission line would remove about 1.1 acres of forestland from timber production diverting it to nonforest uses compatable with the transmission line right-of-way. Depending upon the actualmore » site location the Lopez Island Substation could remove from 1 to 3.2 acres of forestland and 2 acres of pastureland from production. Disturbance of game in the immediate vicintiy of the transmission facilities will occur during construction, as will some soil erosion primarily during and immediately after construction, siltation in nearby streams, disturbance of nearby residents from noise and dust during construction, and some degradation of AM reception immediately adjacent to the right-of-way. 7 figs.« less

  17. Tide-related variability of TAG hydrothermal activity observed by deep-sea monitoring system and OBSH

    NASA Astrophysics Data System (ADS)

    Fujioka, Kantaro; Kobayashi, Kazuo; Kato, Kazuhiro; Aoki, Misumi; Mitsuzawa, Kyohiko; Kinoshita, Masataka; Nishizawa, Azusa

    1997-12-01

    Hydrothermal activities were monitored by an ocean bottom seismometer with hydrophone (OBSH) and a composite measuring system (Manatee) including CTD, current meter, transmission meter and cameras at a small depression on the TAG hydrothermal mound in the Mid-Atlantic Ridge. Low-frequency pressure pulses detected by the hydrophone with semi-diurnal periodicity seem to correspond to cycles of hydrothermal upflow from a small and short-lived smoker vent close to the observing site. The peaks of pressure pulses are synchronous with the maximum gradient of areal strain decrease due to tidal load release. Microearthquakes with very near epicenters occur sporadically and do not appear to be directly correlatable to hydrothermal venting. Temporal variations in bottom water temperature also have semi-diurnal periodicity but are more complicated than the pressure events. Temperatures may be affected both by upwelling of hot water and by lateral flow of the bottom current changing its directions with ocean tide.

  18. Proposed Columbia Wind Farm No. 1 : Final Environmental Impact Statement, Joint NEPA/SEPA.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration; Klickitat County

    1995-09-01

    CARES proposes to construct and operate the 25 megawatt Columbia Wind Farm No. 1 (Project) in the Columbia Hills area of Klickitat County, Washington known as Juniper Point. Wind is not a constant resource and based on the site wind measurement data, it is estimated that the Project would generate approximately 7 average annual MWs of electricity. BPA proposes to purchase the electricity generated by the Project. CARES would execute a contractual agreement with a wind developer, to install approximately 91 wind turbines and associated facilities to generate electricity. The Project`s construction and operation would include: install concrete pier foundationsmore » for each wind turbine; install 91 model AWT-26 wind turbines using 43 m high guyed tubular towers on the pier foundations; construct a new 115/24-kv substation; construct a 149 m{sup 2} steel operations and maintenance building; install 25 pad mount transformers along the turbine access roads; install 4.0 km of underground 24 kv power collection lines to collect power from individual turbines to the end of turbine strings; install 1.2 km of underground communication and transmission lines from each turbine to a pad mount transformer; install 5.6 km of 24 kv wood pole transmission lines to deliver electricity from the pad mount transformers to the Project substation; install 3.2 km of 115 kv wood pole transmission lines to deliver electricity from the Project substation to the Public Utility District No. 1 of Klickitat County(PUD)115 kv Goldendale line; interconnect with the BPA transmission system through the Goldendale line and Goldendale substation owned by the PUD; reconstruct, upgrade, and maintain 8.0 km of existing roads; construct and maintain 6.4 km of new graveled roads along the turbine strings and to individual turbines; and install meteorological towers guyed with rebar anchors on the Project site.« less

  19. Monitoring change in Great Salt Lake

    USGS Publications Warehouse

    Naftz, David L.; Angeroth, Cory E.; Freeman, Michael L.; Rowland, Ryan C.; Carling, Gregory

    2013-01-01

    Despite the ecological and economic importance of Great Salt Lake, only limited water quality monitoring has occurred historically. To change this, new monitoring stations and networks—gauges of lake level height and rate of inflow, moored buoys, and multiple lake-bottom sensors—will provide important information that can be used to make informed decisions regarding future management of the Great Salt Lake ecosystem.

  20. Water-quality, water-level, and lake-bottom-sediment data collected from the defense fuel supply point and adjacent properties, Hanahan, South Carolina, 1990-96

    USGS Publications Warehouse

    Petkewich, M.D.; Vroblesky, D.A.; Robertson, J.F.; Bradley, P.M.

    1997-01-01

    A 9-year scientific investigation to determine the potential for biore-mediation of ground-water contamination and to monitor the effectiveness of an engineered bioremediation system located at the Defense Fuel Supply Point and adjacent properties in Hanahan, S.C., has culminated in the collection of abundant water-quality and water-level data.This report presents the analytical results of the study that monitored the changes in surface- and ground-water quality and water-table elevations in the study area from December 1990 to January 1996. This report also presents analytical results of lake-bottom sediments collected in the study area.

  1. GULF OF MEXICO HYPOXIA MONITORING AND MODELING

    EPA Science Inventory

    Greene, Richard M. and Russell G. Kreis. In press. Gulf of Mexico Hypoxia Monitoring and Modeling (Abstract). To be presented at the EPA Science Forum: Healthy Communities and Ecosystems, 1-3 June 2004, Washington, DC. 1 p. (ERL,GB R990).

    Oxygen-depleted or hypoxic bottom...

  2. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-137- Chemawa-Salem 1&2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sherer, Brett M.

    Vegetation Management for the Chemawa-Salem #1 115 kV and #2 230 kV transmission lines from Chemawa Substation to Salem Substation. BPA proposes to remove unwanted vegetation along the right-of-way, access roads, switch platforms, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have lowgrowing plant communities along the rights-of-way to control the development of potentiallymore » threatening vegetation.« less

  3. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-141- Salem Albany #2)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barndt, Shawn L.

    Vegetation Management for the Salem Albany #2 115 kV transmission line from Salem Substation to Albany Substation. BPA proposes to remove unwanted vegetation along the right-of-way, access roads, switch platforms, microwave beam paths, and around tower structures of the subject transmission line corridor that may impede the operation and maintenance of the identified transmission lines. BPA plans to conduct vegetation control with the goal of removing tall growing vegetation that is currently or will soon be a hazard to the transmission line. BPA’s overall goal is to have low-growing plant communities along the rights-of-way to control the development of potentiallymore » threatening vegetation.« less

  4. Type B investigation of electrical fault in 351 Substation, December 4, 1994

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Debban, H.L.; Shearer, C.A.; Boger, R.M.

    1995-02-01

    On December 4, 1994, at 2132:10 hours, an electrical failure of a cable-tapping splice resulted in a fire in the 300 Area of the DOE Hanford Site. The fire occurred in the yard of Substation 351 in electrical Vault R122V, where the cable-tapping splice was located. The fire incinerated all cables passing to and through the vault causing them to fail. The failure of the cables resulted in a power outage to twenty customers in the 300 Area. The vault was electrically isolated, and power was restored to the electrical distribution system at 2311 hours. This report contains the accidentmore » scenario, accident analysis, direct cause and root and contributing causes.« less

  5. Research on Hydrodynamic Interference Suppression of Bottom-Mounted Monitoring Platform with Fairing Structure

    NASA Astrophysics Data System (ADS)

    Wang, Zhen; Zheng, Yi; Mao, Yu-feng; Wang, Ya-zhou; Yu, Yan-ting; Liu, Hong-ning

    2018-03-01

    In the disturbance of unsteady flow field under the sea, the monitoring accuracy and precision of the bottom-mounted acoustic monitoring platform will decrease. In order to reduce the hydrodynamic interference, the platform wrapped with fairing structure and separated from the retrieval unit is described. The suppression effect evaluation based on the correlation theory of sound pressure and particle velocity for spherical wave in infinite homogeneous medium is proposed and the difference value between them is used to evaluate the hydrodynamic restraining performance of the bottom-mounted platform under far field condition. Through the sea test, it is indicated that the platform with sparse layers fairing structure (there are two layers for the fairing, in which the inside layer is 6-layers sparse metal net, and the outside layer is 1-layer polyester cloth, and then it takes sparse layers for short) has no attenuation in the sound pressure response to the sound source signal, but obvious suppression in the velocity response to the hydrodynamic noise. The effective frequency of the fairing structure is decreased below 10 Hz, and the noise magnitude is reduced by 10 dB. With the comparison of different fairing structures, it is concluded that the tighter fairing structure can enhance the performance of sound transmission and flow restraining.

  6. From the front line to the bottom line: building revenue integrity.

    PubMed

    Britt, John; Adams, Shawn; Snow, Trevor

    2015-07-01

    To improve trends in accounts receivable and a hospital's bottom line without fear of penalty or repayment, organizations should expand the definition of the revenue cycle team by: Engaging front-line clinical and business personnel. Training personnel to understand the roles they play in revenue integrity. Creating scorecards with measurable goals to promote accountability. Monitoring the outcomes and defining real-time, actionable responses to negative variances.

  7. Mapping of sea bottom topography

    NASA Technical Reports Server (NTRS)

    Calkoen, C. J.; Wensink, G. J.; Hesselmans, G. H. F. M.

    1992-01-01

    Under suitable conditions the bottom topography of shallow seas is visible in remote sensing radar imagery. Two experiments were performed to establish which remote sensing technique or combination yields optimal imaging of bottom topography and which hydro-meteorological conditions are favorable. A further goal is to gain experience with these techniques. Two experiments were performed over an area in the North Sea near the measuring platform Meetpost Noordwijk (MPN). The bottom topography in the test area is dominated by sand waves. The crests of the sand waves are perpendicular to the coast line and the dominating (tidal-)current direction. A 4x4 sq km wide section of the test area was studied in more detail. The first experiment was undertaken on 16 Aug. 1989. During the experiment the following remote sensing instruments were used: Landsat-Thematic Mapper, and NASA/JPL Airborne Imaging Radar (AIR). The hydro-meteorological conditions; current, wind, wave, and air and water temperature were monitored by MPN, a ship of Rijkswaterstaat (the OCTANS), and a pitch-and-roll WAVEC-buoy. The second experiment took place on 12 July 1992. During this experiment data were collected with the NASA/JPL polarimetric synthetic aperture radar (SAR), and a five-band helicopter-borne scatterometer. Again the hydro-meteorological conditions were monitored at MPN and the OCTANS. Furthermore, interferometric radar data were collected.

  8. Effect of Mass Proportion of Municipal Solid Waste Incinerator Bottom Ash Layer to Municipal Solid Waste Layer on the Cu and Zn Discharge from Landfill.

    PubMed

    Kong, Qingna; Yao, Jun; Qiu, Zhanhong; Shen, Dongsheng

    2016-01-01

    Municipal solid waste incinerator (MSWI) bottom ash is often used as the protection layer for the geomembrane and intermediate layer in the landfill. In this study, three sets of simulated landfills with different mass proportion of MSWI bottom ash layer to municipal solid waste (MSW) layer were operated. Cu and Zn concentrations in the leachates and MSW were monitored to investigate the effect of MSWI bottom ash layer on the Cu and Zn discharge from the landfill. The results showed that the Zn discharge was dependent on the mass proportion of MSWI bottom ash layer. The pH of landfill was not notably increased when the mass proportion of MSWI bottom ash layer to MSW layer was 1 : 9, resulting in the enhancement of the Zn discharge. However, Zn discharge was mitigated when the mass proportion was 2 : 8, as the pH of landfill was notably promoted. The discharge of Cu was not dependent on the mass proportion, due to the great affinity of Cu to organic matter. Moreover, Cu and Zn contents of the sub-MSW layer increased due to the MSWI bottom ash layer. Therefore, the MSWI bottom ash layer can increase the potential environmental threat of the landfill.

  9. Fire protection system HMI in power plant

    NASA Astrophysics Data System (ADS)

    Zainal, Yuda Bakti

    2015-05-01

    The central power station, a place where there are machines that generate power, equipped with substation where the voltage is produced by the generator and increased to a certain voltage with a step up voltage transformer. Effect on transformer oil is very important, transformer may malfunction if the oil that serves as a coolant and insulator gradually decreased its ability, over time their use. Power transformer on usability is vital, so it needs to be maintained so that the temperature rise must be overcome by applying a temperature control that can inform and control the control valve to open the hydrant tap transformer cooling. HMI implemented to facilitate the operators cope with excess heat in the transformer using thermocouple censor. Test results show that the control transformer and monitored using PLC and HMI. Transformer can maintain the condition of a maximum of 80 degrees Celsius heat.

  10. Development of a spectrofluorimetry-based device for determining the acetylene content in the oils of power transformers.

    PubMed

    Quintella, Cristina M; Meira, Marilena; Silva, Weidson Leal; Filho, Rogério G D; Araújo, André L C; Júnior, Elias T S; Sales, Lindolfo J O

    2013-12-15

    Power transformers are essential for a functioning electrical system and therefore require special attention by maintenance programs because a fault can harm both the company and society. The temperature inside a power transformer and the dissolved gases, which are primarily composed of acetylene, are the two main parameters monitored when detecting faults. This paper describes the development of a device for analyzing the acetylene content in insulating oil using spectrofluorimetry. Using this device introduces a new methodology for the maintaining and operating power transformers. The prototype is currently operating in a substation. The results presented by this system were satisfactory; when compared to chromatographic data, the errors did not exceed 15%. This prototype may be used to confirm the quality of an insulating oil sample to detect faults in power transformers. © 2013 Elsevier B.V. All rights reserved.

  11. A Real-Time Ultraviolet Radiation Imaging System Using an Organic Photoconductive Image Sensor†

    PubMed Central

    Okino, Toru; Yamahira, Seiji; Yamada, Shota; Hirose, Yutaka; Odagawa, Akihiro; Kato, Yoshihisa; Tanaka, Tsuyoshi

    2018-01-01

    We have developed a real time ultraviolet (UV) imaging system that can visualize both invisible UV light and a visible (VIS) background scene in an outdoor environment. As a UV/VIS image sensor, an organic photoconductive film (OPF) imager is employed. The OPF has an intrinsically higher sensitivity in the UV wavelength region than those of conventional consumer Complementary Metal Oxide Semiconductor (CMOS) image sensors (CIS) or Charge Coupled Devices (CCD). As particular examples, imaging of hydrogen flame and of corona discharge is demonstrated. UV images overlapped on background scenes are simply made by on-board background subtraction. The system is capable of imaging weaker UV signals by four orders of magnitude than that of VIS background. It is applicable not only to future hydrogen supply stations but also to other UV/VIS monitor systems requiring UV sensitivity under strong visible radiation environment such as power supply substations. PMID:29361742

  12. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  13. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  14. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  15. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  16. 30 CFR 75.340 - Underground electrical installations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... electrical installations. (a) Underground transformer stations, battery charging stations, substations... with transformers that are either dry-type or contain nonflammable liquid, if they are located at or...

  17. 36 CFR 292.21 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .../forest/grazing uses may also consist of uses related to and in furtherance of the protection of... transmission line systems, substations, commercial radio transmitters, relays or repeater stations, antennas...

  18. 36 CFR 292.21 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    .../forest/grazing uses may also consist of uses related to and in furtherance of the protection of... transmission line systems, substations, commercial radio transmitters, relays or repeater stations, antennas...

  19. QAARM: quasi-anharmonic autoregressive model reveals molecular recognition pathways in ubiquitin

    PubMed Central

    Savol, Andrej J.; Burger, Virginia M.; Agarwal, Pratul K.; Ramanathan, Arvind; Chennubhotla, Chakra S.

    2011-01-01

    Motivation: Molecular dynamics (MD) simulations have dramatically improved the atomistic understanding of protein motions, energetics and function. These growing datasets have necessitated a corresponding emphasis on trajectory analysis methods for characterizing simulation data, particularly since functional protein motions and transitions are often rare and/or intricate events. Observing that such events give rise to long-tailed spatial distributions, we recently developed a higher-order statistics based dimensionality reduction method, called quasi-anharmonic analysis (QAA), for identifying biophysically-relevant reaction coordinates and substates within MD simulations. Further characterization of conformation space should consider the temporal dynamics specific to each identified substate. Results: Our model uses hierarchical clustering to learn energetically coherent substates and dynamic modes of motion from a 0.5 μs ubiqutin simulation. Autoregressive (AR) modeling within and between states enables a compact and generative description of the conformational landscape as it relates to functional transitions between binding poses. Lacking a predictive component, QAA is extended here within a general AR model appreciative of the trajectory's temporal dependencies and the specific, local dynamics accessible to a protein within identified energy wells. These metastable states and their transition rates are extracted within a QAA-derived subspace using hierarchical Markov clustering to provide parameter sets for the second-order AR model. We show the learned model can be extrapolated to synthesize trajectories of arbitrary length. Contact: ramanathana@ornl.gov; chakracs@pitt.edu PMID:21685101

  20. Molecular dynamics simulation of nitric oxide in myoglobin

    USGS Publications Warehouse

    Lee, Myung Won; Meuwly, Markus

    2012-01-01

    The infrared (IR) spectroscopy and ligand migration of photodissociated nitric oxide (NO) in and around the active sites in myoglobin (Mb) are investigated. A distributed multipolar model for open-shell systems is developed and used, which allows one to realistically describe the charge distribution around the diatomic probe molecule. The IR spectra were computed from the trajectories for two conformational substates at various temperatures. The lines are narrow (width of 3–7 cm–1 at 20–100 K), in agreement with the experimental observations where they have widths of 4–5 cm–1 at 4 K. It is found that within one conformational substate (B or C) the splitting of the spectrum can be correctly described compared with recent experiments. Similar to photodissociated CO in Mb, additional substates exist for NO in Mb, which are separated by barriers below 1 kcal/mol. Contrary to full quantum mechanical calculations, however, the force field and mixed QM/MM simulations do not correctly describe the relative shifts between the B- and C-states relative to gas-phase NO. Free energy simulations establish that NO preferably localizes in the distal site and the barrier for migration to the neighboring Xe4 pocket is ΔGB→C = 1.7–2.0 kcal/mol. The reverse barrier is ΔGB←C = 0.7 kcal/mol, which agrees well with the experimental value of 0.7 kcal/mol, estimated from kinetic data.

  1. Anthropogenic radionuclide fluxes and distribution in bottom sediments of the cooling basin of the Ignalina Nuclear Power Plant.

    PubMed

    Marčiulionienė, D; Mažeika, J; Lukšienė, B; Jefanova, O; Mikalauskienė, R; Paškauskas, R

    2015-07-01

    Based on γ-ray emitting artificial radionuclide spectrometric measurements, an assessment of areal and vertical distribution of (137)Cs, (60)Co and (54)Mn activity concentrations in bottom sediments of Lake Drūkšiai was performed. Samples of bottom sediments from seven monitoring stations within the cooling basin were collected in 1988-1996 and 2007-2010 (in July-August). For radionuclide areal distribution analysis, samples from the surface 0-5 cm layer were used. Multi sample cores sliced 2 cm, 3 cm or 5 cm thick were used to study the vertical distribution of radionuclides. The lowest (137)Cs activity concentrations were obtained for two stations that were situated close to channels with radionuclide discharges, but with sediments that had a significantly smaller fraction of organic matter related to finest particles and consequently smaller radionuclide retention potential. The (137)Cs activity concentration was distributed quite evenly in the bottom sediments from other investigated monitoring stations. The highest (137)Cs activity concentrations in the bottom sediments of Lake Drūkšiai were measured in the period of 1988-1989; in 1990, the (137)Cs activity concentrations slightly decreased and they varied insignificantly over the investigation period. The obtained (238)Pu/(239,240)Pu activity ratio values in the bottom sediments of Lake Drūkšiai represented radioactive pollution with plutonium from nuclear weapon tests. Higher (60)Co and (54)Mn activity concentrations were observed in the monitoring stations that were close to the impact zones of the technical water outlet channel and industrial rain drainage system channel. (60)Co and (54)Mn activity concentrations in the bottom sediments of Lake Drūkšiai significantly decreased when operations at both INPP reactor units were stopped. The vertical distribution of radionuclides in bottom sediments revealed complicated sedimentation features, which may have been affected by a number of natural and anthropogenic factors resulting in mixing, resuspension and remobilization of sediments and radionuclides. The associated with particles (137)Cs flux was 129 Bq/(m(2) year). The (137)Cs transfer rate from water into bottom sediments was 14.3 year(-1) (or, the removal time was 25 days). The Kd value for (137)Cs in situ estimated from trap material was 80 m(3)/kg. The associated with particles (60)Co flux was 21 Bq/(m(2) year), when (60)Co activity concentration in sediment trap particles was 15.7 ± 5 Bq/kg. (60)Co activity concentration in soluble form was less than the minimum detectable activity (MDA = 1.3 Bq/m(3)). Then, the conservatively derived Kd value for (60)Co was >90 m(3)/kg. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. 40 CFR 98.438 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... substations, circuit breakers, other switchgear, gas-insulated lines, or power transformers. Fluorinated GHG... transformers containing a fluorinated GHG prior to sale or distribution, or offer for sale or distribution in...

  3. 40 CFR 98.438 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... substations, circuit breakers, other switchgear, gas-insulated lines, or power transformers. Fluorinated GHG... transformers containing a fluorinated GHG prior to sale or distribution, or offer for sale or distribution in...

  4. 40 CFR 98.438 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... substations, circuit breakers, other switchgear, gas-insulated lines, or power transformers. Fluorinated GHG... transformers containing a fluorinated GHG prior to sale or distribution, or offer for sale or distribution in...

  5. Feasibility study of wireless power transmission systems

    NASA Technical Reports Server (NTRS)

    Robinson, W. J., Jr.

    1968-01-01

    Wireless microwave or laser energy transfers power from a manned earth-orbiting central station to unmanned astronomical substations. More efficient systems are required for the microwave power transmission.

  6. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  7. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  8. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  9. 36 CFR 14.78 - Applications.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... application should include a one-line diagram of the proposed line and the immediate interconnecting facilities including power plants and substations, a power flow diagram for proposed line and connecting...

  10. Achieving thermography with a thermal security camera using uncooled amorphous silicon microbolometer image sensors

    NASA Astrophysics Data System (ADS)

    Wang, Yu-Wei; Tesdahl, Curtis; Owens, Jim; Dorn, David

    2012-06-01

    Advancements in uncooled microbolometer technology over the last several years have opened up many commercial applications which had been previously cost prohibitive. Thermal technology is no longer limited to the military and government market segments. One type of thermal sensor with low NETD which is available in the commercial market segment is the uncooled amorphous silicon (α-Si) microbolometer image sensor. Typical thermal security cameras focus on providing the best image quality by auto tonemaping (contrast enhancing) the image, which provides the best contrast depending on the temperature range of the scene. While this may provide enough information to detect objects and activities, there are further benefits of being able to estimate the actual object temperatures in a scene. This thermographic ability can provide functionality beyond typical security cameras by being able to monitor processes. Example applications of thermography[2] with thermal camera include: monitoring electrical circuits, industrial machinery, building thermal leaks, oil/gas pipelines, power substations, etc...[3][5] This paper discusses the methodology of estimating object temperatures by characterizing/calibrating different components inside a thermal camera utilizing an uncooled amorphous silicon microbolometer image sensor. Plots of system performance across camera operating temperatures will be shown.

  11. Broken rail track detection using smart materials

    NASA Astrophysics Data System (ADS)

    Bouteiller, Fanny; Grisso, Benjamin L.; Peairs, Daniel M.; Inman, Daniel J.

    2006-03-01

    Rail lines are subject to many types of damage that, in the worst cases, can cause train derailments. The damage can arise from either manufacturing defects or external factors, possibly even terrorist acts to disrupt the civil infrastructure. Current rail inspection techniques require train traffic to be interrupted while workers and equipment move along the track. Moreover, a technician with rail testing experience is required to analyze the results. This paper focuses on simple proof of concept experiments to determine if impedance based structural health monitoring may be used to detect anomalies in rail tracks, and in particular broken rails. The technique applies a very low voltage (one volt) high frequency wave to a structure, measures its response and determines the location and extent of a rail break. The monitoring device is envisioned to run off of ambient vibration and thermal gradients provided by passing trains and daily thermal cycles, store the energy and utilize the stored energy periodically to inspect the track (according to the track usage schedule). If damage occurs or starts to occur, a warning signal would be transmitted to substation then broadcast to the appropriate operator listing the location and extent of the damage.

  12. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  13. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  14. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  15. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  16. 7 CFR 1726.14 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... electric system, e.g., a substation transformer, heat exchanger or a transmission structure. Force account... which is combined with equipment to form an electric system, e.g., poles, insulators, or conductors...

  17. 30 CFR 75.380 - Escapeways; bituminous and lignite mines.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Underground transformer stations, battery charging stations, substations, and rectifiers except— (A) Where... rectifiers and power centers with transformers that are either dry-type or contain nonflammable liquid...

  18. Variation in Vaccination Data Available at School Entry Across the United States.

    PubMed

    Leslie, Timothy F; Street, Erica J; Delamater, Paul L; Yang, Y Tony; Jacobsen, Kathryn H

    2016-12-01

    To compile substate-level data on US school-age children's vaccination rates. For states that did not have suitable data online, in 2015 we submitted information requests to the state health department and followed up with the state's Freedom of Information Act when necessary. The accessibility, scale, and types of vaccination data varied considerably. Whereas 26 states provided data online, 14 released data only after a Freedom of Information Act request. School or school-district data were available for 24 states, 19 at the county level, 2 at the health department level, and 6 provided no substate-level data. Effective vaccination policy requires a robust understanding of vaccination behavior. Some states make it difficult to access data or provide low-resolution data of limited value for identifying vaccination behavior.

  19. Characterization of the conformational equilibrium between the two major substates of RNase A using NMR chemical shifts.

    PubMed

    Camilloni, Carlo; Robustelli, Paul; De Simone, Alfonso; Cavalli, Andrea; Vendruscolo, Michele

    2012-03-07

    Following the recognition that NMR chemical shifts can be used for protein structure determination, rapid advances have recently been made in methods for extending this strategy for proteins and protein complexes of increasing size and complexity. A remaining major challenge is to develop approaches to exploit the information contained in the chemical shifts about conformational fluctuations in native states of proteins. In this work we show that it is possible to determine an ensemble of conformations representing the free energy surface of RNase A using chemical shifts as replica-averaged restraints in molecular dynamics simulations. Analysis of this surface indicates that chemical shifts can be used to characterize the conformational equilibrium between the two major substates of this protein. © 2012 American Chemical Society

  20. Experience in the installation of a microprocessor system for controlling converter units of the Vyborg substation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gusakovskii, K. B.; Zmaznov, E. Yu.; Katantsev, S. V.

    The experience in the installation of modern digital systems for controlling converter units at the Vyborg converter substation on the basis of advanced microprocessor devices is considered. It is shown that debugging of a control and protection system on mathematical and physical models does not guarantee optimum control of actual converter devices. Examples of advancing the control and protection system are described, the necessity for which has become obvious in tests of actual equipment. Comparison of oscillograms of processes before optimization of the control system and after its optimization and adjustment shows that the digital control system makes it possiblemore » to improve substantially the algorithms of control and protection in the short term and without changing the hardware component.« less

  1. Integrated, Automated Distributed Generation Technologies Demonstration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jensen, Kevin

    2014-09-01

    The purpose of the NETL Project was to develop a diverse combination of distributed renewable generation technologies and controls and demonstrate how the renewable generation could help manage substation peak demand at the ATK Promontory plant site. The Promontory plant site is located in the northwestern Utah desert approximately 25 miles west of Brigham City, Utah. The plant encompasses 20,000 acres and has over 500 buildings. The ATK Promontory plant primarily manufactures solid propellant rocket motors for both commercial and government launch systems. The original project objectives focused on distributed generation; a 100 kW (kilowatt) wind turbine, a 100 kWmore » new technology waste heat generation unit, a 500 kW energy storage system, and an intelligent system-wide automation system to monitor and control the renewable energy devices then release the stored energy during the peak demand time. The original goal was to reduce peak demand from the electrical utility company, Rocky Mountain Power (RMP), by 3.4%. For a period of time we also sought to integrate our energy storage requirements with a flywheel storage system (500 kW) proposed for the Promontory/RMP Substation. Ultimately the flywheel storage system could not meet our project timetable, so the storage requirement was switched to a battery storage system (300 kW.) A secondary objective was to design/install a bi-directional customer/utility gateway application for real-time visibility and communications between RMP, and ATK. This objective was not achieved because of technical issues with RMP, ATK Information Technology Department’s stringent requirements based on being a rocket motor manufacturing facility, and budget constraints. Of the original objectives, the following were achieved: • Installation of a 100 kW wind turbine. • Installation of a 300 kW battery storage system. • Integrated control system installed to offset electrical demand by releasing stored energy from renewable sources during peak hours of the day. Control system also monitors the wind turbine and battery storage system health, power output, and issues critical alarms. Of the original objectives, the following were not achieved: • 100 kW new technology waste heat generation unit. • Bi-directional customer/utility gateway for real time visibility and communications between RMP and ATK. • 3.4% reduction in peak demand. 1.7% reduction in peak demand was realized instead.« less

  2. 81. THREE ADDITIONAL BLACK AND WHITE VIDEO MONITORS LOCATED IMMEDIATELY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    81. THREE ADDITIONAL BLACK AND WHITE VIDEO MONITORS LOCATED IMMEDIATELY WEST OF THOSE IN CA-133-1-A-80. COMPLEX SAFETY WARNING LIGHTS FOR SLC-3E (PAD 2) AND BLDG. 763 (LOB) LOCATED ABOVE MONITOR 3; GREEN LIGHTS ON BOTTOM OF EACH STACK ILLUMINATED. LEFT TO RIGHT BELOW MONITORS: ACCIDENT REPORTING EMERGENCY NOTIFICATION SYSTEM TELEPHONE, ATLAS H FUEL COUNTER, AND DIGITAL COUNTDOWN CLOCK. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  3. Effect of Mass Proportion of Municipal Solid Waste Incinerator Bottom Ash Layer to Municipal Solid Waste Layer on the Cu and Zn Discharge from Landfill

    PubMed Central

    Kong, Qingna; Qiu, Zhanhong; Shen, Dongsheng

    2016-01-01

    Municipal solid waste incinerator (MSWI) bottom ash is often used as the protection layer for the geomembrane and intermediate layer in the landfill. In this study, three sets of simulated landfills with different mass proportion of MSWI bottom ash layer to municipal solid waste (MSW) layer were operated. Cu and Zn concentrations in the leachates and MSW were monitored to investigate the effect of MSWI bottom ash layer on the Cu and Zn discharge from the landfill. The results showed that the Zn discharge was dependent on the mass proportion of MSWI bottom ash layer. The pH of landfill was not notably increased when the mass proportion of MSWI bottom ash layer to MSW layer was 1 : 9, resulting in the enhancement of the Zn discharge. However, Zn discharge was mitigated when the mass proportion was 2 : 8, as the pH of landfill was notably promoted. The discharge of Cu was not dependent on the mass proportion, due to the great affinity of Cu to organic matter. Moreover, Cu and Zn contents of the sub-MSW layer increased due to the MSWI bottom ash layer. Therefore, the MSWI bottom ash layer can increase the potential environmental threat of the landfill. PMID:28044139

  4. 76 FR 26286 - Environmental Impacts Statements; Notice of Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-06

    ... the Red Bluff Substation, California Desert Conservation Area (CDCA Plan, Riverside County, CA, Review..., Biodiversity, and Natural Production of Anadromous Salmonids, Kittitas County, WA, Review Period Ends: 05/16...

  5. Thermal and Denaturation Studies of the Time-Resolved Fluorescence Decay of Human Superoxide Dismutase

    NASA Astrophysics Data System (ADS)

    Silva, Norberto De Jesus

    Previous studies have shown that time-resolved fluorescence decay of various single tryptophan proteins is best described by a distribution of fluorescence lifetimes rather than one or two lifetimes. The thermal dependence of the lifetime distributions is consistent with the hypothesis that proteins fluctuate between a hierarchy of many conformational substates. With this scenario as a theoretical framework, the correlations between protein dynamic and structure are investigated by studying the time-resolved fluorescence and anisotropy decay of the single tryptophan (Trp) residue of human superoxide dismutase (HSOD) over a wide range of temperatures and at different denaturant concentrations. First, it is demonstrated that the center of the lifetime distribution can characterize the average deactivation environment of the excited Trp-protein system. A qualitative model is introduced to explain the time-resolved fluorescence decay of HSOD in 80% glycerol over a wide range of temperatures. The dynamical model features isoenergetic conformational substates separated by a hierarchy of energy barriers. The HSOD system is also investigated as a function of denaturant concentration in aqueous solution. As a function of guanidine hydrochloride (GdHCl), the width of the fluorescence lifetime distribution of HSOD displays a maximum which is not coincident with the fully denatured form of HSOD at 6.5M GdHCl. Furthermore, the width for the fully denatured form of HSOD is greater than that of the native form. This is consistent with the scenario that more conformational substates are being created upon denaturation of HSOD. HSOD is a dimeric protein and it was observed that the width of the lifetime distribution of HSOD at intermediate GdHCl concentrations increased with decreasing protein concentration. In addition, the secondary structure of HSOD at intermediate GdHCl concentration does not change with protein concentration. These results suggest that HSOD display structural microheterogeneity which is consistent with the hypothesis of conformational substates. Further analysis show that, during denaturation, the monomeric form of HSOD is an intermediate which displays native-like secondary structure and fluctuating tertiary structure; i.e., the monomeric form of HSOD is a molten globule.

  6. Benefits and shortcomings of non-destructive benthic imagery for monitoring hard-bottom habitats.

    PubMed

    Beisiegel, Kolja; Darr, Alexander; Gogina, Mayya; Zettler, Michael L

    2017-08-15

    Hard-bottom habitats with complex topography and fragile epibenthic communities are still not adequately considered in benthic monitoring programs, despite their potential ecological importance. While indicators of ecosystem health are defined by major EU directives, methods commonly used to measure them are deficient in quantification of biota on hard surfaces. We address the suitability of seafloor imaging for monitoring activities. We compared the ability of high-resolution imagery and physical sampling methods (grab, dredge, SCUBA-diving) to detect taxonomic and functional components of epibenthos. Results reveal that (1) with minimal habitat disturbance on large spatial scales, imagery provides valuable, cost-effective assessment of rocky reef habitat features and community structure, (2) despite poor taxonomic resolution, image-derived data for habitat-forming taxa might be sufficient to infer richness of small sessile and mobile fauna, (3) physical collections are necessary to develop a robust record of species richness, including species-level taxonomic identifications, and to establish a baseline. Copyright © 2017. Published by Elsevier Ltd.

  7. 75 FR 80807 - Environmental Impact Statements; Notice of Availability

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-23

    ..., CA, East County Substation/Tule Wind/ Energia Sierra Juarez Gen-Tie Projects, Construction and.... 20100462, Draft EIS, FWS, CA, Santa Clara Valley Habitat Plan, To Protect and Enhance Ecological Diversity...

  8. SOUTH FRONT AND EAST SIDE. January, 1998 Edwards Air ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SOUTH FRONT AND EAST SIDE. January, 1998 - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Electrical Substation, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  9. 75 FR 4338 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-27

    ... administered by Rural Business Service (RBS) through Rural Development State and sub-State Offices serving each... current economic crisis. The information is used by RBS loan officers and approval officials to determine...

  10. 30 CFR 57.4130 - Surface electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4130 Surface electric...

  11. A Multi-agent Based Cooperative Voltage and Reactive Power Control

    NASA Astrophysics Data System (ADS)

    Ishida, Masato; Nagata, Takeshi; Saiki, Hiroshi; Shimada, Ikuhiko; Hatano, Ryousuke

    In order to maintain system voltage within the optimal range and prevent voltage instability phenomena before they occur, a variety of phase modifying equipment is installed in optimal locations throughout the power system network and a variety of methods of voltage reactive control are employed. The proposed system divided the traditional method to control voltage and reactive power into two sub problems; “voltage control” to adjust the secondary bus voltage of substations, and “reactive power control” to adjust the primary bus voltage. In this system, two types of agents are installed in substations in order to cooperate “voltage control” and “reactive power control”. In order to verify the performance of the proposed method, it has been applied to the model network system. The results confirm that our proposed method is able to control violent fluctuations in load.

  12. ANCA: Anharmonic Conformational Analysis of Biomolecular Simulations.

    PubMed

    Parvatikar, Akash; Vacaliuc, Gabriel S; Ramanathan, Arvind; Chennubhotla, S Chakra

    2018-05-08

    Anharmonicity in time-dependent conformational fluctuations is noted to be a key feature of functional dynamics of biomolecules. Although anharmonic events are rare, long-timescale (μs-ms and beyond) simulations facilitate probing of such events. We have previously developed quasi-anharmonic analysis to resolve higher-order spatial correlations and characterize anharmonicity in biomolecular simulations. In this article, we have extended this toolbox to resolve higher-order temporal correlations and built a scalable Python package called anharmonic conformational analysis (ANCA). ANCA has modules to: 1) measure anharmonicity in the form of higher-order statistics and its variation as a function of time, 2) output a storyboard representation of the simulations to identify key anharmonic conformational events, and 3) identify putative anharmonic conformational substates and visualization of transitions between these substates. Copyright © 2018 Biophysical Society. Published by Elsevier Inc. All rights reserved.

  13. Digital interface of electronic transformers based on embedded system

    NASA Astrophysics Data System (ADS)

    Shang, Qiufeng; Qi, Yincheng

    2008-10-01

    Benefited from digital interface of electronic transformers, information sharing and system integration in substation can be realized. An embedded system-based digital output scheme of electronic transformers is proposed. The digital interface is designed with S3C44B0X 32bit RISC microprocessor as the hardware platform. The μCLinux operation system (OS) is transplanted on ARM7 (S3C44B0X). Applying Ethernet technology as the communication mode in the substation automation system is a new trend. The network interface chip RTL8019AS is adopted. Data transmission is realized through the in-line TCP/IP protocol of uClinux embedded OS. The application result and character analysis show that the design can meet the real-time and reliability requirements of IEC60044-7/8 electronic voltage/current instrument transformer standards.

  14. Dynamic Simulation on the Installation Process of HGIS in Transformer Substation

    NASA Astrophysics Data System (ADS)

    Lin, Tao; Li, Shaohua; Wang, Hu; Che, Deyong; Qi, Guangcai; Yao, Jianfeng; Zhang, Qingzhe

    The technological requirements of Hypid Gas Insulated Switchgear (HGIS) installation in transformer substation is high and the control points of quality is excessive. Most of the engineers and technicians in the construction enterprises are not familiar with equipments of HGIS. In order to solve these problem, equipments of HGIS is modeled on the computer by SolidWorks software. Installation process of civil foundation and closed-type equipments is optimized dynamically with virtual assemble technology. Announcements and application work are composited into animation file. Skills of modeling and simulation is tidied classify as well. The result of the visual dynamic simulation can instruct the actual construction process of HGIS to a certain degree and can promote reasonable construction planning and management. It can also improve the method and quality of staff training for electric power construction enterprises.

  15. Application of Superconducting Power Cables to DC Electric Railway Systems

    NASA Astrophysics Data System (ADS)

    Ohsaki, Hiroyuki; Lv, Zhen; Sekino, Masaki; Tomita, Masaru

    For novel design and efficient operation of next-generation DC electric railway systems, especially for their substantial energy saving, we have studied the feasibility of applying superconducting power cables to them. In this paper it is assumed that a superconducting power cable is applied to connect substations supplying electric power to trains. An analysis model line was described by an electric circuit, which was analyzed with MATLAB-Simulink. From the calculated voltages and currents of the circuit, the regenerative brake and the energy losses were estimated. In addition, assuming the heat loads of superconducting power cables and the cryogenic efficiency, the energy saving of the total system was evaluated. The results show that the introduction of superconducting power cables could achieve the improved use of regenerative brake, the loss reduction, the decreased number of substations, the reduced maintenance, etc.

  16. Frustration-guided motion planning reveals conformational transitions in proteins

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Budday, Dominik; Fonseca, Rasmus; Leyendecker, Sigrid

    Proteins exist as conformational ensembles, exchanging between substates to perform their function. Advances in experimental techniques yield unprecedented access to structural snapshots of their conformational landscape. However, computationally modeling how proteins use collective motions to transition between substates is challenging owing to a rugged landscape and large energy barriers. Here in this paper, we present a new, robotics-inspired motion planning procedure called dCCRRT that navigates the rugged landscape between substates by introducing dynamic, interatomic constraints to modulate frustration. The constraints balance non-native contacts and flexibility, and instantaneously redirect the motion towards sterically favorable conformations. On a test set of eightmore » proteins determined in two conformations separated by, on average, 7.5Å root mean square deviation (RMSD), our pathways reduced the Cα atom RMSD to the goal conformation by 78%, outperforming peer methods. Additionally, we then applied dCC-RRT to examine how collective, small-scale motions of four side-chains in the active site of cyclophilin A propagate through the protein. dCC-RRT uncovered a spatially contiguous network of residues linked by steric interactions and collective motion connecting the active site to a recently proposed, non-canonical capsid binding site 25Å away, rationalizing NMR and multi-temperature crystallography experiments. In all, dCC-RRT can reveal detailed, all-atom molecular mechanisms for small and large amplitude motions.Source code and binaries are freely available at https://github.com/ExcitedStates/KGS/.« less

  17. Frustration-guided motion planning reveals conformational transitions in proteins.

    PubMed

    Budday, Dominik; Fonseca, Rasmus; Leyendecker, Sigrid; van den Bedem, Henry

    2017-10-01

    Proteins exist as conformational ensembles, exchanging between substates to perform their function. Advances in experimental techniques yield unprecedented access to structural snapshots of their conformational landscape. However, computationally modeling how proteins use collective motions to transition between substates is challenging owing to a rugged landscape and large energy barriers. Here, we present a new, robotics-inspired motion planning procedure called dCC-RRT that navigates the rugged landscape between substates by introducing dynamic, interatomic constraints to modulate frustration. The constraints balance non-native contacts and flexibility, and instantaneously redirect the motion towards sterically favorable conformations. On a test set of eight proteins determined in two conformations separated by, on average, 7.5 Å root mean square deviation (RMSD), our pathways reduced the Cα atom RMSD to the goal conformation by 78%, outperforming peer methods. We then applied dCC-RRT to examine how collective, small-scale motions of four side-chains in the active site of cyclophilin A propagate through the protein. dCC-RRT uncovered a spatially contiguous network of residues linked by steric interactions and collective motion connecting the active site to a recently proposed, non-canonical capsid binding site 25 Å away, rationalizing NMR and multi-temperature crystallography experiments. In all, dCC-RRT can reveal detailed, all-atom molecular mechanisms for small and large amplitude motions. Source code and binaries are freely available at https://github.com/ExcitedStates/KGS/. © 2017 Wiley Periodicals, Inc.

  18. Frustration-guided motion planning reveals conformational transitions in proteins

    DOE PAGES

    Budday, Dominik; Fonseca, Rasmus; Leyendecker, Sigrid; ...

    2017-07-12

    Proteins exist as conformational ensembles, exchanging between substates to perform their function. Advances in experimental techniques yield unprecedented access to structural snapshots of their conformational landscape. However, computationally modeling how proteins use collective motions to transition between substates is challenging owing to a rugged landscape and large energy barriers. Here in this paper, we present a new, robotics-inspired motion planning procedure called dCCRRT that navigates the rugged landscape between substates by introducing dynamic, interatomic constraints to modulate frustration. The constraints balance non-native contacts and flexibility, and instantaneously redirect the motion towards sterically favorable conformations. On a test set of eightmore » proteins determined in two conformations separated by, on average, 7.5Å root mean square deviation (RMSD), our pathways reduced the Cα atom RMSD to the goal conformation by 78%, outperforming peer methods. Additionally, we then applied dCC-RRT to examine how collective, small-scale motions of four side-chains in the active site of cyclophilin A propagate through the protein. dCC-RRT uncovered a spatially contiguous network of residues linked by steric interactions and collective motion connecting the active site to a recently proposed, non-canonical capsid binding site 25Å away, rationalizing NMR and multi-temperature crystallography experiments. In all, dCC-RRT can reveal detailed, all-atom molecular mechanisms for small and large amplitude motions.Source code and binaries are freely available at https://github.com/ExcitedStates/KGS/.« less

  19. The Influence of Climate Change on the Intensity of Ice Gouging of the Bottom by Hummocky Formations

    NASA Astrophysics Data System (ADS)

    Ogorodov, S. A.; Arkhipov, V. V.; Baranskaya, A. V.; Kokin, O. V.; Romanov, A. O.

    2018-02-01

    In the present work, several results of repeated sounding of bottom ice gouging microrelief within the area of the underwater pipeline crossing of the Baydaratskaya Bay, Kara Sea, are presented. Based on the results of the monitoring, as well as the analysis of literature sources and modeling it has been established that under the conditions of climate warming and sea ice reduction, the zone of the most intensive ice gouging is shifted landwards, on shallower water areas.

  20. First deployment of a Multiparameter Ocean Bottom System in the Mediterranean sea

    NASA Astrophysics Data System (ADS)

    Hello, Y.; Charvis, P.; Yegikyan, M.; Rivet, D.; Deschamps, A.

    2016-12-01

    Continuous monitoring of oceans is the next great scientific and technical challenge. Recently several cabled sea bottom observatories were developed in Canada (Neptune), in Japan (DONET) and in France (Antares) for real time monitoring of seismic activity, dynamics of the water column, global environmental changes, observation of marine life, the detection of neutrinos, etc. Nevertheless, these initiatives are costly to install and to maintain and it is unlikely that we can deploy many similar observatories in the near future. Among the most recent alternative we developed a 3-years autonomy system equipped with a Nanometrics Trillium 120 s, a triaxial accelerometer, a differential and an absolute pressure gauge, and a hydrophone. MUG-OBS (Multiparameter Geophysical Ocean Bottom system) is a free falling instrument rated down to 6000 m for the monitoring of geophysical signals (earthquakes, submarine landslides, other transient signals, …). The major innovation is that it is possible to recover the data any time on demand (regularly every 6-months or after a crisis) using one of the 6 data-shuttles released from the surface by acoustic command. The MUG-OBS prototype was tested in situ twice for a short period of one week in the bay of Villefranche-sur-mer (French Riviera) in November 2015 and March 2016. During these periods we were lucky to record several teleseismic events with an excellent signal to noise ratio. In September 2016 the instrument will be deployed in the Ligurian sea, 35 miles offshore the city of Nice, for a three-years period, to extend offshore the regional land seismic network. We will present the first seismic signals available from this new instrument. MUG-OBS is a user friendly design and once installed can be maintained by non-specialists to recover data using ship of opportunity. This make it a good challenger to be deployed along the subduction of South America in the frame of the future Subduction Zone Observatory. Such a sea bottom system could also be equipped with other sensors (ADCP, underwater Methane sensor, CO2 flow-through sensor,…) and could be used as a multidisciplinary platform for the environmental monitoring of the deep Ocean.

  1. Monitoring of coastal coral reefs near Dahab (Gulf of Aqaba, Red Sea) indicates local eutrophication as potential cause for change in benthic communities.

    PubMed

    Naumann, Malik S; Bednarz, Vanessa N; Ferse, Sebastian C A; Niggl, Wolfgang; Wild, Christian

    2015-02-01

    Coral reef ecosystems fringing the coastline of Dahab (South Sinai, Egypt) have experienced increasing anthropogenic disturbance as an emergent international tourism destination. Previous reports covering tourism-related impacts on coastal environments, particularly mechanical damage and destructive fishing, have highlighted the vital necessity for regular ecosystem monitoring of coral reefs near Dahab. However, a continuous scientific monitoring programme of permanent survey sites has not been established to date. Thus, this study conducted in situ monitoring surveys to investigate spatio-temporal variability of benthic reef communities and selected reef-associated herbivores along with reef health indicator organisms by revisiting three of the locally most frequented dive sites during expeditions in March 2010, September 2011 and February 2013. In addition, inorganic nutrient concentrations in reef-surrounding waters were determined to evaluate bottom-up effects of key environmental parameters on benthic reef community shifts in relation to grazer-induced top-down control. Findings revealed that from 2010 to 2013, live hard coral cover declined significantly by 12 % at the current-sheltered site Three Pools (TP), while showing negative trends for the Blue Hole (BH) and Lighthouse (LH) sites. Hard coral cover decline was significantly and highly correlated to a substantial increase in turf algae cover (up to 57 % at TP) at all sites, replacing hard corals as dominant benthic space occupiers in 2013. These changes were correlated to ambient phosphate and ammonium concentrations that exhibited highest values (0.64 ± 0.07 μmol PO4 (3-) l(-1), 1.05 ± 0.07 μmol NH4 (+) l(-1)) at the degraded site TP. While macroalgae appeared to respond to both bottom-up and top-down factors, change in turf algae was consistent with expected indications for bottom-up control. Temporal variability measured in herbivorous reef fish stocks reflected seasonal impacts by local fisheries, with concomitant changes in macroalgal cover. These findings represent the first record of rapid, localised change in benthic reef communities near Dahab, consistent with indications for bottom-up controlled early-stage phase shifts, underlining the necessity for efficient regional wastewater management for coastal facilities.

  2. Water Quality Monitoring in the Execution of Canal Remediation Methods in the Florida Keys

    NASA Astrophysics Data System (ADS)

    Serna, A.; Briceno, H.

    2016-02-01

    Monitoring data indicate relatively high nutrient concentrations in waters close to shore along the Florida Keys, and corresponding responses from the system, such as higher phytoplankton biomass, turbidity and light attenuation as well as lower oxygenation and lower salinities of the water column. These changes, associated to human impact, have become more obvious near canal mouths. Waters close to shore show characteristics closely related to those in residential canals, affected by quick movement of infiltrated runoff and wastewaters (septic tanks), tides and high water table. Many canals do not meet the minimum water quality (WQ) criteria established by the State of Florida and are a potential source of contaminants to near shore waters designated as Outstanding Florida Waters. Canal remediation is being conducted by the Monroe County targeting poor circulation and organic matter accumulation. The restoration technologies include reduction in weed wrack, enhanced circulation, organic removal and partial backfilling. The objective of WQ monitoring is to measure the status and trends of WQ parameters to evaluate progress toward achieving and maintaining WQ standards and protecting/restoring the living marine resources. Monitoring followed a Before-and-After-Control-Impact scheme (BACI). Field measurements, included diel observations and vertical profiles of physical-chemical properties (salinity, DO, %DO saturation, temperature and turbidity) and nutrient analysis. Comparing profiles between remediated and control canals indicated similar patterns in physicochemical properties, and suggesting larger seasonal than spatial variability. BACI diel observations, in surface and bottom waters of remediated canals indicated little difference for surface waters, but significant improvements for bottom waters. Most surface waters are well oxygenated, while bottom waters show a significant increase in DO following culvert installation.

  3. Beale Air Force Base, Perimeter Acquisition Vehicle Entry PhasedArray Warning ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Electric Substation, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  4. Looking north Beale Air Force Base, Perimeter Acquisition Vehicle ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Looking north - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Electric Substation, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  5. CNPQ/INPE LANDSAT system

    NASA Technical Reports Server (NTRS)

    Parada, N. D. J. (Principal Investigator); Barbosa, M. N.; Escada, J. B., Jr.

    1983-01-01

    The current status of the Brazilian LANDSAT facilities is described and main accomplishments are outlined. Receiving, recording, and processing substations and data distribution centers are discussed. Examples of the preliminary TM product produced by the Brazilian station are given.

  6. Monitoring oriental fruit moth (Lepidoptera: Tortricidae) with sticky traps baited with terpinyl acetate and sex pheromone

    USDA-ARS?s Scientific Manuscript database

    Studies in Argentina and Chile during 2010-11 evaluated a new trap (Ajar) for monitoring the oriental fruit moth, Grapholita molesta (Busck). The Ajar trap was delta-shaped with a jar filled with a terpinyl acetate plus brown sugar bait attached to the bottom center of the trap. The screened lid of ...

  7. 40 CFR 60.2635 - What are the operator training and qualification requirements?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Combustion controls and monitoring. (v) Operation of air pollution control equipment and factors affecting... devices. (vii) Actions to correct malfunctions or conditions that may lead to malfunction. (viii) Bottom...

  8. MUG-OBS - Multiparameter Geophysical Ocean Bottom System : a new instrumental approach to monitor earthquakes.

    NASA Astrophysics Data System (ADS)

    hello, yann; Charvis, Philippe; Yegikyan, Manuk; verfaillie, Romain; Rivet, Diane

    2016-04-01

    Real time monitoring of seismic activity is a major issue for early warning of earthquakes and tsunamis. It can be done using regional scale wired nodes, such as Neptune in Canada and in the U.S, or DONET in Japan. Another approach to monitor seismic activity at sea is to deploying repeatedly OBS array like during the amphibious Cascadia Initiative (four time 1-year deployments), the Japanese Pacific Array (broadband OBSs "ocean-bottom broadband dispersion survey" with 2-years autonomy), the Obsismer program in the French Lesser Antilles (eight time 6-months deployments) and the Osisec program in Ecuador (four time 6-months deployments). These autonomous OBSs are self-recovered or recovered using an ROV. These systems are costly including ship time, and require to recover the OBS before to start working on data. Among the most recent alternative we developed a 3/4 years autonomy ocean bottom system with 9 channels (?) allowing the acquisition of different seismic or environmental parameters. MUG-OBS is a free falling instrument rated down to 6000 m. The installation of the sensor is monitored by acoustic commands from the surface and a health bulletin with data checking is recovered by acoustic during the installation. The major innovation is that it is possible to recover the data any time on demand (regularly every 6-months or after a crisis) using one of the 6 data-shuttles released from the surface by acoustic command using a one day fast cruise boat of opportunity. Since sensors stayed at the same location for 3 years, it is a perfect tool to monitor large seismic events, background seismic activity and aftershock distribution. Clock, drift measurement and GPS localization is automatic when the shuttle reaches the surface. For remote areas, shuttles released automatically and a seismic events bulletin is transmitted. Selected data can be recovered by two-way Iridium satellite communication. After a period of 3 years the main station is self-recovered by acoustic.

  9. Heavy Metal Contamination of Soils around a Hospital Waste Incinerator Bottom Ash Dumps Site

    PubMed Central

    Adama, M.; Esena, R.; Fosu-Mensah, B.; Yirenya-Tawiah, D.

    2016-01-01

    Waste incineration is the main waste management strategy used in treating hospital waste in many developing countries. However, the release of dioxins, POPs, and heavy metals in fly and bottom ash poses environmental and public health concerns. To determine heavy metal (Hg, Pb, Cd, Cr, and Ag) in levels in incinerator bottom ash and soils 100 m around the incinerator bottom ash dump site, ash samples and surrounding soil samples were collected at 20 m, 40 m, 60 m, 80 m, 100 m, and 1,200 m from incinerator. These were analyzed using the absorption spectrophotometer method. The geoaccumulation (I geo) and pollution load indices (PLI) were used to assess the level of heavy metal contamination of surrounding soils. The study revealed high concentrations in mg/kg for, Zn (16417.69), Pb (143.80), Cr (99.30), and Cd (7.54) in bottom ash and these were above allowable limits for disposal in landfill. The study also found soils within 60 m radius of the incinerator to be polluted with the metals. It is recommended that health care waste managers be educated on the implication of improper management of incinerator bottom ash and regulators monitor hospital waste incinerator sites. PMID:27034685

  10. Basic characteristics of leachate produced by various washing processes for MSWI ashes in Taiwan.

    PubMed

    Yang, Renbo; Liao, Wing-Ping; Wu, Pin-Han

    2012-08-15

    Approximately 19.2% of Taiwan's municipal solid waste (MSW) that passes through incineration disposal is converted into ashes (including bottom ash and fly ash). Although bottom ash can pass nearly all of the standards of the toxicity characteristic leaching procedure (TCLP), its high chloride content makes its reuse limited; it generally cannot be used as a fine aggregate material in concrete applications. This research examined washing four types of bottom ash (BA) and fly ash (FA) with water to reduce their chloride content. The optimal water intensity for washing pretreated bottom ash was found to be 7-8L of water per kg of bottom ash, and the optimal water intensity for washing untreated fly ash was found to be 20-25 L of water per kg of fly ash. Based on regression analyses of the chloride concentrations of the leachates and their electrical conductivity (EC) values, each MSW incineration plant has its own ash characteristics as well as a specific regression line in bottom or fly ash leachate. Clearly, it is possible to monitor the EC values of the leachates online by estimation from regression equations to determine the chloride concentrations in the leachates. Crown Copyright © 2012. Published by Elsevier Ltd. All rights reserved.

  11. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  12. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  13. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  14. Electricity Delivery and its Environmental Impacts

    EPA Pesticide Factsheets

    Explains electricity delivery in the U.S. and its impacts on the environment. After a centralized power plant generates electricity, the electricity must be delivered to the end-user. Follow the path of electricity through transmission, substation, and dis

  15. 6. SECOND FLOOR, LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. SECOND FLOOR, LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR

  16. 5. WEST MEZZANINE, LOOKING NORTH, AREA PREVIOUSLY CONTAINED HIGH TENSION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. WEST MEZZANINE, LOOKING NORTH, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR

  17. 7 CFR 1728.98 - Electric standards and specifications.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... for Pad-Mounted Transformers (Single and Three-Phase) (1-77). (19) Bulletin 50-74 (U-6), RUS... Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78). (21) Bulletin 1728F-700...

  18. 7 CFR 1728.98 - Electric standards and specifications.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... for Pad-Mounted Transformers (Single and Three-Phase) (1-77). (19) Bulletin 50-74 (U-6), RUS... Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78). (21) Bulletin 1728F-700...

  19. 7 CFR 1728.98 - Electric standards and specifications.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... for Pad-Mounted Transformers (Single and Three-Phase) (1-77). (19) Bulletin 50-74 (U-6), RUS... Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78). (21) Bulletin 1728F-700...

  20. 7 CFR 1728.97 - Incorporation by reference of electric standards and specifications.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...-73 (U-5), RUS Specifications for Pad-Mounted Transformers (Single and Three-Phase) (1-77) Bulletin 50...), RUS Specifications for Step-Down Distribution Substation Transformers (34.4-138 kV) (1-78) Bulletin...

  1. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  2. 29 CFR 1926.408 - Special systems.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Electrical Installation Safety Requirements § 1926... electrical connections. The enclosure shall have provision for locking so only authorized qualified persons... as substations, trailers, cars, mobile shovels, draglines, hoists, drills, dredges, compressors...

  3. Effects of aging on the structural, mechanical, and thermal properties of the silicone rubber current transformer insulation bushing for a 500 kV substation.

    PubMed

    Wang, Zhigao; Zhang, Xinghai; Wang, Fangqiang; Lan, Xinsheng; Zhou, Yiqian

    2016-01-01

    In order to analyze the cracking and aging reason of the silicone rubber current transformer (CT) insulation bushing used for 8 years from a 500 kV alternating current substation, characteristics including Fourier transform infrared (FTIR) spectroscopy, mechanical properties analysis, hardness, and thermo gravimetric analysis have been carried out. The FTIR results indicated that the external surface of the silicone rubber CT insulation bushing suffered from more serious aging than the internal part, fracture of side chain Si-C bond was much more than the backbone. Mechanical properties and thermal stability results illustrated that the main aging reasons were the breakage of side chain Si-C bond and the excessive cross-linking reaction of the backbone. This study can provide valuable basis for evaluating degradation mechanism and aging state of the silicone rubber insulation bushing in electric power field.

  4. Extremum Seeking Control of Smart Inverters for VAR Compensation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arnold, Daniel; Negrete-Pincetic, Matias; Stewart, Emma

    2015-09-04

    Reactive power compensation is used by utilities to ensure customer voltages are within pre-defined tolerances and reduce system resistive losses. While much attention has been paid to model-based control algorithms for reactive power support and Volt Var Optimization (VVO), these strategies typically require relatively large communications capabilities and accurate models. In this work, a non-model-based control strategy for smart inverters is considered for VAR compensation. An Extremum Seeking control algorithm is applied to modulate the reactive power output of inverters based on real power information from the feeder substation, without an explicit feeder model. Simulation results using utility demand informationmore » confirm the ability of the control algorithm to inject VARs to minimize feeder head real power consumption. In addition, we show that the algorithm is capable of improving feeder voltage profiles and reducing reactive power supplied by the distribution substation.« less

  5. The laboratory millimeter-wave spectrum of methyl formate in its ground torsional E state

    NASA Technical Reports Server (NTRS)

    Plummer, G. M.; Herbst, E.; De Lucia, F. C.; Blake, G. A.

    1986-01-01

    Over 250 rotational transitions of the internal rotor methyl formate (HCOOCH3) in its ground v(t) = 0 degenerate (E) torsional substate have been measured in the millimeter-wave spectral region. These data and a number of E-state lines identified by several other workers have been analyzed using an extension of the classical principal-axis method in the high barrier limit. The resulting rotational constants allow accurate prediction of the v(t) = 0 E substate methyl formate spectrum below 300 GHz between states with angular momentum J not greater than 30 and rotational energy of not more than 350/cm. The calculated transition frequencies for the E state, when combined with the results of the previous analysis of the ground-symmetric, nondegenerate state, account for over 200 of the emission lines observed toward Orion in a recent survey of the 215-265 GHz band.

  6. Preventive overhaul time for power transformers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarmadi, M.; Rouhi, J.; Fayyaz, A.

    Power transformers are the major piece of equipment in high-voltage substations. A considerable number of these transformers exist in Iran`s integrated network. Due to the climate diversity and improper usage, many of these transformers age rapidly, suffer failure and are taken out of service before half their useful life. At the present time the utility companies have no specific time-frame and plan for preventive overhaul. Detection of preventive overhaul time will increase the remaining life of transformers and improve the reliability of substations. An exact check of the remaining lifetime of transformers is not yet possible by available diagnostic techniques.more » In this paper, the authors present a method of identifying the right time for preventive overhaul in 63 kV power transformers. This method is developed based on 25 year transformer performance records in Northern Iran (subtropical climate) and with the utilization of studies done by electrical engineering communities world-wide.« less

  7. Study of seismic response and vibration control of High voltage electrical equipment damper based on TMD

    NASA Astrophysics Data System (ADS)

    Liu, Chuncheng; Wang, Chongyang; Mao, Long; Zha, Chuanming

    2016-11-01

    Substation high voltage electrical equipment such as mutual inductor, circuit interrupter, disconnecting switch, etc., has played a key role in maintaining the normal operation of the power system. When the earthquake disaster, the electrical equipment of the porcelain in the transformer substation is the most easily to damage, causing great economic losses. In this paper, using the method of numerical analysis, the establishment of a typical high voltage electrical equipment of three dimensional finite element model, to study the seismic response of a typical SF6 circuit breaker, at the same time, analysis and contrast the installation ring tuned mass damper (TMD damper for short), by changing the damper damping coefficient and the mass block, install annular TMD vibration control effect is studied. The results of the study for guiding the seismic design of high voltage electrical equipment to provide valuable reference.

  8. A dynamic mechanism for allosteric activation of Aurora kinase A by activation loop phosphorylation.

    PubMed

    Ruff, Emily F; Muretta, Joseph M; Thompson, Andrew R; Lake, Eric W; Cyphers, Soreen; Albanese, Steven K; Hanson, Sonya M; Behr, Julie M; Thomas, David D; Chodera, John D; Levinson, Nicholas M

    2018-02-21

    Many eukaryotic protein kinases are activated by phosphorylation on a specific conserved residue in the regulatory activation loop, a post-translational modification thought to stabilize the active DFG-In state of the catalytic domain. Here we use a battery of spectroscopic methods that track different catalytic elements of the kinase domain to show that the ~100 fold activation of the mitotic kinase Aurora A (AurA) by phosphorylation occurs without a population shift from the DFG-Out to the DFG-In state, and that the activation loop of the activated kinase remains highly dynamic. Instead, molecular dynamics simulations and electron paramagnetic resonance experiments show that phosphorylation triggers a switch within the DFG-In subpopulation from an autoinhibited DFG-In substate to an active DFG-In substate, leading to catalytic activation. This mechanism raises new questions about the functional role of the DFG-Out state in protein kinases. © 2018, Ruff et al.

  9. Photovoltaic central station step and touch potential considerations in grounding system design

    NASA Technical Reports Server (NTRS)

    Engmann, G.

    1983-01-01

    The probability of hazardous step and touch potentials is an important consideration in central station grounding system design. Steam turbine generating station grounding system design is based on accepted industry practices and there is extensive in-service experience with these grounding systems. A photovoltaic (PV) central station is a relatively new concept and there is limited experience with PV station grounding systems. The operation and physical configuration of a PV central station is very different from a steam electric station. A PV station bears some similarity to a substation and the PV station step and touch potentials might be addressed as they are in substation design. However, the PV central station is a generating station and it is appropriate to examine the effect that the differences and similarities of the two types of generating stations have on step and touch potential considerations.

  10. Two-dimensional vibrational spectroscopy of the amide I band of crystalline acetanilide: Fermi resonance, conformational substates, or vibrational self-trapping?

    NASA Astrophysics Data System (ADS)

    Edler, J.; Hamm, P.

    2003-08-01

    Two-dimensional infrared (2D-IR) spectroscopy is applied to investigate acetanilide, a molecular crystal consisting of quasi-one-dimensional hydrogen bonded peptide units. The amide-I band exhibits a double peak structure, which has been attributed to different mechanisms including vibrational self-trapping, a Fermi resonance, or the existence of two conformational substates. The 2D-IR spectrum of crystalline acetanilide is compared with that of two different molecular systems: (i) benzoylchloride, which exhibits a strong symmetric Fermi resonance and (ii) N-methylacetamide dissolved in methanol which occurs in two spectroscopically distinguishable conformations. Both 2D-IR spectra differ significantly from that of crystalline acetanilide, proving that these two alternative mechanisms cannot account for the anomalous spectroscopy of crystalline acetanilide. On the other hand, vibrational self-trapping of the amide-I band can naturally explain the 2D-IR response.

  11. How main-chains of proteins explore the free-energy landscape in native states.

    PubMed

    Senet, Patrick; Maisuradze, Gia G; Foulie, Colette; Delarue, Patrice; Scheraga, Harold A

    2008-12-16

    Understanding how a single native protein diffuses on its free-energy landscape is essential to understand protein kinetics and function. The dynamics of a protein is complex, with multiple relaxation times reflecting a hierarchical free-energy landscape. Using all-atom molecular dynamics simulations of an alpha/beta protein (crambin) and a beta-sheet polypeptide (BS2) in their "native" states, we demonstrate that the mean-square displacement of dihedral angles, defined by 4 successive C(alpha) atoms, increases as a power law of time, t(alpha), with an exponent alpha between 0.08 and 0.39 (alpha = 1 corresponds to Brownian diffusion), at 300 K. Residues with low exponents are located mainly in well-defined secondary elements and adopt 1 conformational substate. Residues with high exponents are found in loops/turns and chain ends and exist in multiple conformational substates, i.e., they move on multiple-minima free-energy profiles.

  12. How main-chains of proteins explore the free-energy landscape in native states

    PubMed Central

    Senet, Patrick; Maisuradze, Gia G.; Foulie, Colette; Delarue, Patrice; Scheraga, Harold A.

    2008-01-01

    Understanding how a single native protein diffuses on its free-energy landscape is essential to understand protein kinetics and function. The dynamics of a protein is complex, with multiple relaxation times reflecting a hierarchical free-energy landscape. Using all-atom molecular dynamics simulations of an α/β protein (crambin) and a β-sheet polypeptide (BS2) in their “native” states, we demonstrate that the mean-square displacement of dihedral angles, defined by 4 successive Cα atoms, increases as a power law of time, tα, with an exponent α between 0.08 and 0.39 (α = 1 corresponds to Brownian diffusion), at 300 K. Residues with low exponents are located mainly in well-defined secondary elements and adopt 1 conformational substate. Residues with high exponents are found in loops/turns and chain ends and exist in multiple conformational substates, i.e., they move on multiple-minima free-energy profiles. PMID:19073932

  13. Joint HVAC transmission EMF environmental study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stormshak, F.; Thompson, J.

    1992-05-01

    This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identifymore » any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration's Ostrander Substation near Estacada, Oregon.« less

  14. Joint HVAC Transmission EMF Environmental Study : Final Report on Experiment 1.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    United States. Bonneville Power Administration; Oregon Regional Primate Research Center

    1992-05-01

    This document describes the rationale, procedures, and results of a carefully controlled study conducted to establish whether chronic exposure of female (ewe) Suffolk lambs to the environment of a 500-kV 60-Hz transmission line would affect various characteristics of growth, endocrine function, and reproductive development. This experiment used identical housing and management schemes for control and line-exposed ewes, thus minimizing these factors as contributors to between-group experimental error. Further, throughout the 10-month duration of this study, changes in electric and magnetic fields, audible noise, and weather conditions were monitored continuously by a computerized system. Such measurements provided the opportunity to identifymore » any relationship between environmental factors and biological responses. Because of reports in the literature that electric and magnetic fields alter concentrations of melatonin in laboratory animals, the primary objective of this study was to ascertain whether a similar effect occurs in lambs exposed to a 500-kV a-c line in a natural setting. In addition, onset of puberty, changes in body weight, wool growth, and behavior were monitored. To determine whether the environment of a 500-kV line caused stress in the study animals, serum levels of cortisol were measured. The study was conducted at Bonneville Power Administration`s Ostrander Substation near Estacada, Oregon.« less

  15. Spectral methods for study of the G-protein-coupled receptor rhodopsin. II. Magnetic resonance methods

    NASA Astrophysics Data System (ADS)

    Struts, A. V.; Barmasov, A. V.; Brown, M. F.

    2016-02-01

    This article continues our review of spectroscopic studies of G-protein-coupled receptors. Magnetic resonance methods including electron paramagnetic resonance (EPR) and nuclear magnetic resonance (NMR) provide specific structural and dynamical data for the protein in conjunction with optical methods (vibrational, electronic spectroscopy) as discussed in the accompanying article. An additional advantage is the opportunity to explore the receptor proteins in the natural membrane lipid environment. Solid-state 2H and 13C NMR methods yield information about both the local structure and dynamics of the cofactor bound to the protein and its light-induced changes. Complementary site-directed spin-labeling studies monitor the structural alterations over larger distances and correspondingly longer time scales. A multiscale reaction mechanism describes how local changes of the retinal cofactor unlock the receptor to initiate large-scale conformational changes of rhodopsin. Activation of the G-protein-coupled receptor involves an ensemble of conformational substates within the rhodopsin manifold that characterize the dynamically active receptor.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The Western Area Power Administration (Western) has established a formal environmental protection, auditing, monitoring, and planning program that has been in effect since 1978. The significant environmental projects and issues Western was involved with in 1995 are discussed in this annual site environmental report. It is written to show the nature and effectiveness of the environmental protection program. Western operates and maintains nearly 17,000 miles of transmission lines, 257 substations, and various appurtenant power facilities in fifteen central and western states. Western is also responsible for planning, construction, and operation and maintenance of additional federal transmission facilities that may bemore » authorized in the future. There is a combined total of 55 hydroelectric power generating plants in the service area. Additionally, Western markets the US entitlement from the Navajo coal-fired plant near Page, Arizona. The Department of Energy requires the preparation of an annual site environmental report. Because Western has over 400 facilities located in these states, this report addresses the environmental activities in all the facilities as one site.« less

  17. Load Segmentation for Convergence of Distribution Automation and Advanced Metering Infrastructure Systems

    NASA Astrophysics Data System (ADS)

    Pamulaparthy, Balakrishna; KS, Swarup; Kommu, Rajagopal

    2014-12-01

    Distribution automation (DA) applications are limited to feeder level today and have zero visibility outside of the substation feeder and reaching down to the low-voltage distribution network level. This has become a major obstacle in realizing many automated functions and enhancing existing DA capabilities. Advanced metering infrastructure (AMI) systems are being widely deployed by utilities across the world creating system-wide communications access to every monitoring and service point, which collects data from smart meters and sensors in short time intervals, in response to utility needs. DA and AMI systems convergence provides unique opportunities and capabilities for distribution grid modernization with the DA system acting as a controller and AMI system acting as feedback to DA system, for which DA applications have to understand and use the AMI data selectively and effectively. In this paper, we propose a load segmentation method that helps the DA system to accurately understand and use the AMI data for various automation applications with a suitable case study on power restoration.

  18. Biological Monitoring Density Values

    DOE Data Explorer

    Horne, John

    2017-04-11

    Density values from active acoustic measurements at South Energy Test Site. This data correspond to a bottom mounted upward-looking WBAT, deployed from April 19th to September 30th. Samples (175 pings) were collected hourly at 1Hz.

  19. Environmental and Water Quality Operational Studies. General Guidelines for Monitoring Contaminants in Reservoirs

    DTIC Science & Technology

    1986-02-01

    espacially trte for the topics of sampling and analytical methods, statistical considerations, and the design of general water quality monitoring networks. For...and to the establishment and habitat differentiation of biological populations within reservoirs. Reservoir operatirn, esp- cially the timing...8217 % - - % properties of bottom sediments, as well as specific habitat associations of biological populations of reservoirs. Thus, such heterogeneities

  20. Geophysical monitoring of the submerged area of the Campi Flegrei caldera (Southern Italy): experiences and perspectives

    NASA Astrophysics Data System (ADS)

    Iannaccone, Giovanni; Guardato, Sergio; De Martino, Prospero; Donnarumma, Gian Paolo; Bobbio, Antonella; Chierici, Francesco; Pignagnoli, Luca; Beranzoli, Laura

    2016-04-01

    The monitoring system of the Campi Flegrei caldera is made up of a dense geophysical network of seismological and geodetic instruments with data acquired and processed at the Monitoring Center of INGV in Naples. As one third of the caldera is covered by the sea, a marine monitoring system has been operating since 2008 in the center of the gulf of Pozzuoli, where the sea depth is about 100 m at ~2.5 km from the coast. The main component of the monitoring system is CUMAS (Cabled Underwater Multidisciplinary Acquisition System), which consists of a sea floor module equipped with geophysical and oceanographic sensors (broad band seismometer, accelerometer, hydrophone, bottom pressure recorder and single point three component water-current meter) and status and control sensors. CUMAS is connected by cable to the top of an elastic beacon buoy equipped with the power supply and data transmission devices. The buoy consists of a float placed below sea level, surrounding and holding a steel pole that supports a turret structure above sea level. The pole, turret and float system are rigidly connected to the ballast on the sea bottom. Thus a GPS installed on the turret can record the vertical sea floor displacement related to the volcanic activity of the area. The GPS has operated since January 2012 with continuous acquisition lasting more than three years and has recorded a cumulative seafloor uplift of about 7-8 cm. The comparison of the pattern of the GPS buoy data with those of the land stations confirms a quasi-symmetrical vertical displacement field of the caldera area. Measurement of vertical sea floor displacement has also been obtained by the analysis of bottom pressure recorder data. These results, in conjunction with the analysis of seismic and hydrophone data, have encouraged us to extend the marine monitoring system with the deployment in the Gulf of Pozzuoli of three new similar systems. We also present preliminary results of the first few months of activity of these new systems.

  1. Advanced concepts and solutions for geothermal heating applied in Oradea, Romania

    NASA Astrophysics Data System (ADS)

    Antal, C.; Popa, F.; Mos, M.; Tigan, D.; Popa, B.; Muresan, V.

    2017-01-01

    Approximately 70% of the total population of Oradea benefits from centralized heating, about 55,000 apartments and 159,000 inhabitants are connected. The heating system of Oradea consists of: sources of thermal energy production (Combined heat and power (CHP) I Oradea and geothermal water heating plants); a transport network of heat; heat distribution network for heating and domestic hot water; substations, most of them equipped with worn and obsolete equipment. Recently, only a few heat exchangers were rehabilitated and electric valves were installed to control the water flow. After heat extraction, geothermal chilled waters from the Oradea area are: discharged into the sewer system of the city, paying a fee to the local water company which manages the city’s sewers; discharged into the small river Peta; or re-injected into the reservoir. In order to ensure environmental protection and a sustainable energy development in Oradea, renewable sources of energy have been promoted in recent years. In this respect, the creation of a new well for geothermal water re-injection into the reservoir limits any accidental thermal pollution of the environment, while ensuring the conservation properties of the aquifer by recharging with geothermal chilled water. The paper presents the achievements of such a project whose aim is to replace thermal energy obtained from coal with geothermal heating. The novelty consists in the fact that within the substation we will replace old heat exchangers, circulation pumps and valves with fully automated substations operating in parallel on both a geothermal system and on a primary heating system of a thermal plant.

  2. Determining insulation condition of 110kV instrument transformers. Linking PD measurement results from both gas chromatography and electrical method

    NASA Astrophysics Data System (ADS)

    Dan, C.; Morar, R.

    2017-05-01

    Working methods for on site testing of insulations: Gas chromatography (using the TFGA-P200 chromatographer); Electrical measurements of partial discharge levels using the digital detection, recording, analysis and partial discharge acquisition system, MPD600. First performed, between 2000-2015, were the chromatographic analyses concerning electrical insulating environments of: 102 current transformers, 110kV. Items in operation, functioning in 110/20kV substations. 38 voltage transformers, 110kV also in operation, functioning in 110/20kV substations. Then, electrical measurements of partial discharge inside instrument transformers, on site (power substations) were made (starting in the year 2009, over a 7-year period, collecting data until the year 2015) according to the provisions of standard EN 61869-1:2007 „Instrument transformers. General requirements”, applying, assimilated to it, type A partial discharge test procedure, using as test voltage the very rated 110kV distribution grid voltage. Given the results of two parallel measurements, containing: to this type of failure specific gas amount (H 2) and the quantitative partial discharge’ level, establishing a clear dependence between the quantity of partial discharges and the type and amount of in oil dissolved gases inside equipments affected by this type of defect: partial discharges, was expected. Of the „population” of instrument transformers subject of the two parallel measurements, the dependency between Q IEC (apparent charge) and (H 2) (hydrogen, gas amount dissolved within their insulating environment) represents a finite assemblage situated between the two limits developed on an empirical basis.

  3. Temperatures and Water Levels at Tanana Flats Monitoring Stations

    DTIC Science & Technology

    2008-04-01

    a Druck pressure trans- ducer near the bottom. In response to this drawdown, the initial record showed a water level of 1.13 m on 1 April 2005, which...gradually increased to 1.68 m on 8 April. Freezing of the sensor on 9–10 April ended the reli- able water level record. A pair of replacement Drucks ...again, and a new Druck was installed to replace those that had been frozen. With rising tem- peratures at the bottom of the well, an injection of 400 g

  4. 8. Photocopy of Station Grounding drawing showing floor plans (from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    8. Photocopy of Station Grounding drawing showing floor plans (from the BPA Engineering Vault, Drawing 005319, 3 May 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  5. NORTH REAR AND WEST SIDE, Looking southeast down Saturn Boulevard. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH REAR AND WEST SIDE, Looking southeast down Saturn Boulevard. February, 1998 - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Electrical Substation, Test Area 1-115, northwest end of Saturn Boulevard, Boron, Kern County, CA

  6. 30 CFR 57.4160 - Underground electric substations and liquid storage facilities.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention and Control Prohibitions/precautions/housekeeping § 57.4160... noncombustible materials with equivalent fire protection characteristics. ...

  7. 76 FR 63920 - Eldorado Pumped Storage, LLC.; Notice of Preliminary Permit Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-14

    ... Marketplace, McCullough, or Eldorado substations. The tentative source for initial fill of water and evaporation compensation would be the Southern Nevada Water Authority. The specific routing for that water...

  8. 15 CFR 90.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... non-functioning county or statistical equivalent means a sub-state entity that does not function as an... program, an eligible governmental unit also includes the District of Columbia and non-functioning counties or statistical equivalents represented by a FSCPE member agency. ...

  9. 76 FR 16766 - ECOsponsible, Inc.; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... feasibility of the Niagara River Community Hydro Project (Niagara Project or project) to be located on the... electricity to an onshore collection substation and point of interconnection switchyard; (3) an operations and...

  10. Evaporation characteristics of thin film liquid argon in nano-scale confinement: A molecular dynamics study

    NASA Astrophysics Data System (ADS)

    Hasan, Mohammad Nasim; Shavik, Sheikh Mohammad; Rabbi, Kazi Fazle; Haque, Mominul

    2016-07-01

    Molecular dynamics simulation has been carried out to explore the evaporation characteristics of thin liquid argon film in nano-scale confinement. The present study has been conducted to realize the nano-scale physics of simultaneous evaporation and condensation inside a confined space for a three phase system with particular emphasis on the effect of surface wetting conditions. The simulation domain consisted of two parallel platinum plates; one at the top and another at the bottom. The fluid comprised of liquid argon film at the bottom plate and vapor argon in between liquid argon and upper plate of the domain. Considering hydrophilic and hydrophobic nature of top and bottom surfaces, two different cases have been investigated: (i) Case A: Both top and bottom surfaces are hydrophilic, (ii) Case B: both top and bottom surfaces are hydrophobic. For all cases, equilibrium molecular dynamics (EMD) was performed to reach equilibrium state at 90 K. Then the lower wall was set to four different temperatures such as 110 K, 120 K, 130 K and 140 K to perform non-equilibrium molecular dynamics (NEMD). The variation of temperature and density as well as the variation of system pressure with respect to time were closely monitored for each case. The heat fluxes normal to top and bottom walls were estimated and discussed to illuminate the effectiveness of heat transfer in both hydrophilic and hydrophobic confinement at various boundary temperatures of the bottom plate.

  11. A distributed fluid level sensor suitable for monitoring fuel load on board a moving fuel tank

    NASA Astrophysics Data System (ADS)

    Arkwright, John W.; Parkinson, Luke A.; Papageorgiou, Anthony W.

    2018-02-01

    A temperature insensitive fiber Bragg grating sensing array has been developed for monitoring fluid levels in a moving tank. The sensors are formed from two optical fibers twisted together to form a double helix with pairs of fiber Bragg gratings located above one another at the points where the fibers are vertically disposed. The sensing mechanism is based on a downwards deflection of the section of the double helix containing the FBGs which causes the tension in the upper FBG to decrease and the tension in the lower FBG to increase with concomitant changes in Bragg wavelength in each FBG. Changes in ambient temperature cause a common mode increase in Bragg wavelength, thus monitoring the differential change in wavelength provides a temperature independent measure of the applied pressure. Ambient temperature can be monitored simultaneously by taking the average wavelength of the upper and lower FBGs. The sensors are able to detect variations in pressure with resolutions better than 1 mmH2O and when placed on the bottom of a tank can be used to monitor fluid level based on the recorded pressure. Using an array of these sensors located along the bottom of a moving tank it was possible to monitor the fluid level at multiple points and hence dynamically track the total fluid volume in the tank. The outer surface of the sensing array is formed from a thin continuous Teflon sleeve, making it suitable for monitoring the level of volatile fluids such as aviation fuel and gasoline.

  12. Michigan sub-state area long range plans : final summary report

    DOT National Transportation Integrated Search

    1995-09-01

    Extensive change will mark the future of transportation in Michigan. To meet this challenge, the Michigan Department of Transportation (M.DOT) embarked upon the creation of a statewide plan to chart improvements to the transportation system and to de...

  13. 76 FR 35874 - Union Electric Company (dba Ameren Missouri); Notice of Application Accepted for Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-20

    ... generators with a total installed capacity of 408 megawatts; (5) an excavated tailrace and open channel to the lower reservoir; (6) a 138-kilovolt switchyard/ substation; (7) a gravel and sedimentation trap...

  14. 51. LOOKING NORTHEAST AT EIMCO WASTE WATER TREATMENT THICKENER No. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    51. LOOKING NORTHEAST AT EIMCO WASTE WATER TREATMENT THICKENER No. 2, ELECTRIC POWERHOUSE No. 2, AND OUTDOOR ELECTRICAL SUBSTATION IN BACKGROUND. (Jet Lowe) - U.S. Steel Duquesne Works, Blast Furnace Plant, Along Monongahela River, Duquesne, Allegheny County, PA

  15. 7. SECOND FLOOR, EAST SIDE OF BUILDING LOOKING SOUTHEAST, AREA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. SECOND FLOOR, EAST SIDE OF BUILDING LOOKING SOUTHEAST, AREA PREVIOUSLY CONTAINED HIGH TENSION BUS AND SWITCHING EQUIPMENT FOR BUILDINGS L1 AND L2 - Portland General Electric Company, Lincoln Substation, 1841 Southeast Water Street, Portland, Multnomah County, OR

  16. 1. ENVIRONMENT, FROM NORTHWEST, SHOWING B&P INTERLOCKING TOWER AND POWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    1. ENVIRONMENT, FROM NORTHWEST, SHOWING B&P INTERLOCKING TOWER AND POWER SUBSTATIONS - Baltimore & Potomac Interlocking Tower, Adjacent to AMTRAK railroad tracks in block bounded by Howard Street, Jones Falls Expressway, Maryland Avenue & Falls Road, Baltimore, Independent City, MD

  17. 76 FR 48853 - FFP Project 70, LLC; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-09

    ...-up transformer and high-side and low-side disconnects; (8) a 900-foot-long, 161-kilovolt (kV) transmission line connecting the substation to Ameren UE's existing infrastructure; and (9) appurtenant...

  18. 76 FR 16766 - ECOsponsible, Inc.; Notice of Preliminary Permit Application Accepted for Filing and Soliciting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-25

    ... feasibility of the Niagara River Community Hydro Project 2 (Niagara 2 Project or project) to be located on the... electricity to an onshore collection substation and point of interconnection switchyard; (3) an operations and...

  19. Fiber-optic sensor applications in civil and geotechnical engineering

    NASA Astrophysics Data System (ADS)

    Habel, Wolfgang R.; Krebber, Katerina

    2011-09-01

    Different types of fiber-optic sensors based on glass or polymeric fibers are used to evaluate material behavior or to monitor the integrity and long-term stability of load-bearing structure components. Fiber-optic sensors have been established as a new and innovative measurement technology in very different fields, such as material science, civil engineering, light-weight structures, geotechnical areas as well as chemical and high-voltage substations. Very often, mechanical quantities such as deformation, strain or vibration are requested. However, measurement of chemical quantities in materials and structure components, such as pH value in steel reinforced concrete members also provides information about the integrity of concrete structures. A special fiber-optic chemical sensor for monitoring the alkaline state (pH value) of the cementitious matrix in steel-reinforced concrete structures with the purpose of early detection of corrosion-initiating factors is described. The paper presents the use of several fiber-optic sensor technologies in engineering. One example concerns the use of highly resolving concrete-embeddable fiber Fabry-Perot acoustic emission (AE) sensors for the assessment of the bearing behaviour of large concrete piles in existing foundations or during and after its installation. Another example concerns fiber Bragg grating (FBG) sensors attached to anchor steels (micro piles) to measure the strain distribution in loaded soil anchors. Polymer optical fibers (POF) can be — because of their high elasticity and high ultimate strain — well integrated into textiles to monitor their deformation behaviour. Such "intelligent" textiles are capable of monitoring displacement of soil or slopes, critical mechanical deformation in geotechnical structures (dikes, dams, and embankments) as well as in masonry structures during and after earthquakes.

  20. An investigation of the PM2.5 and NO2 concentrations and their human health impacts in the metro subway system of Suzhou, China.

    PubMed

    Cao, Shi-Jie; Kong, Xiang-Ri; Li, Linyan; Zhang, Weirong; Ye, Zi-Ping; Deng, Yelin

    2017-05-24

    This study measured the particle concentrations with an aerodynamic diameter smaller than 2.5 μm (PM 2.5 ), nitrogen dioxide (NO 2 ), and relative humidity (RH) at five metro subway stations in Suzhou's subway system (Lines 1 and 2). The real-time monitoring campaign was conducted from March 30 th to April 10 th and August 4 th to August 21 st , 2015. The monitoring practice was carried out during rush (7:00-9:00 AM and 17:00-19:00 PM) and regular hours (other times) at the ground and underground levels under different weather conditions with a purpose of obtaining representative data. The monitored results show that the concentrations of PM 2.5 in the train carriages were lower than the concentrations at the underground platforms during both spring and summer. The mean PM 2.5 concentrations at all the underground platforms in all the sub-stations monitored were significantly higher than those at the ground level. The human health impact was calculated to be 6300 annual DALYs (or 375 deaths) due to exposure to the subway system in Suzhou according to the UNEP-SETAC toxicity (USEtox) model. Linear regression models were applied to evaluate the relationships between the PM 2.5 , NO 2 concentrations, and RH. We found that a 10% increment in RH from the current average level of 50-60% can lead to a 9.8 μg m -3 concentration decrease in PM 2.5 . This further results in the total human health impact being reduced to 2451 DALYs (150-4753 DALYs), representing a 20% decrease (1.2-38%).

  1. Long-term temperature monitoring at the biological community site on the Nankai accretionary prism off Kii Peninsula

    NASA Astrophysics Data System (ADS)

    Goto, S.; Hamamoto, H.; Yamano, M.; Kinoshita, M.; Ashi, J.

    2008-12-01

    Nankai subduction zone off Kii Peninsula is one of the most intensively surveyed areas for studies on the seismogenic zone. Multichannel seismic reflection surveys carried out in this area revealed the existence of splay faults that branched from the subduction zone plate boundary [Park et al., 2002]. Along the splay faults, reversal of reflection polarity was observed, indicating elevated pore fluid pressure along the faults. Cold seepages with biological communities were discovered along a seafloor outcrop of one of the splay faults through submersible observations. Long-term temperature monitoring at a biological community site along the outcrop revealed high heat flow carried by upward fluid flow (>180 mW/m2) [Goto et al., 2003]. Toki et al. [2004] estimated upward fluid flow rates of 40-200 cm/yr from chloride distribution of interstitial water extracted from sediments in and around biological community sites along the outcrop. These observation results suggest upward fluid flow along the splay fault. In order to investigate hydrological nature of the splay fault, we conducted long-term temperature monitoring again in the same cold seepage site where Goto et al. [2003] carried out long-term temperature monitoring. In this presentation, we present results of the temperature monitoring and estimate heat flow carried by upward fluid flow from the temperature records. In this long-term temperature monitoring, we used stand-alone heat flow meter (SAHF), a probe-type sediment temperature recorder. Two SAHFs (SAHF-3 and SAHF-4) were used in this study. SAHF-4 was inserted into a bacterial mat, within several meters of which the previous long-term temperature monitoring was conducted. SAHF-3 was penetrated into ordinary sediment near the bacterial mat. The sub-bottom temperature records were obtained for 8 months. The subsurface temperatures oscillated reflecting bottom- water temperature variation (BTV). For sub-bottom temperatures measured with SAHF-3 (outside of the bacterial mat), we found that the effects of the BTV propagated into sediment by conduction only. By correcting the effect of the BTV, conductive heat flow estimated is higher than 100 mW/m2. Sub-bottom temperatures measured within bacterial mat (SAHF-4) except for the topmost sensor could be explained by a conduction model. The heat flow estimated based on the conduction model is similar to that measured with SAHF-3. The temperature of the topmost sensor is slightly higher than that expected from the conduction model. To explain the high temperature, upward fluid flow at a rate of 10-7 m/s order is needed. Heat flow carried by the upward fluid flow is higher than that estimated by Goto et al. [2003]. Heat flow value expected from the distribution of heat flow around this area is 70-80 mW/m2. The high heat flow values inside and outside the bacterial mat estimated in the present and previous studies may reflect upward fluid flow along the splay fault.

  2. 75 FR 13299 - Lower Colorado River Authority Transmission Services Corporation; Construction, Operation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-19

    ...] Lower Colorado River Authority Transmission Services Corporation; Construction, Operation, Maintenance... activities associated with LCRA TSC's construction, maintenance, operation, and repair of four Competitive..., substation upgrades, and access roads) required to be constructed by the Public Utility Commission of Texas...

  3. 76 FR 54752 - Union Electric Company (dba Ameren Missouri); Notice of Application Ready for Environmental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-02

    ... open channel to the lower reservoir; (6) a 138-kilovolt switchyard/ substation; (7) a gravel and sedimentation trap (bin wall) on the East Fork of the Black River; and (8) associated ancillary equipment. m. A...

  4. 7. Photocopy of Elevations drawing (from the BPA Engineering Vault, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    7. Photocopy of Elevations drawing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 3, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  5. Big Creek Hydroelectric System, East & West Transmission Line, 241mile ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Big Creek Hydroelectric System, East & West Transmission Line, 241-mile transmission corridor extending between the Big Creek Hydroelectric System in the Sierra National Forest in Fresno County and the Eagle Rock Substation in Los Angeles, California, Visalia, Tulare County, CA

  6. Electrical Equipment of Electrical Stations and Substations,

    DTIC Science & Technology

    1979-10-25

    of Communist society. In 1921 he wrote: "fhe sole material base of socialism can be the large/coarse machine industry, capable of reorganizing and...produced with the aid of special switching system, structurally/ constructionally being part transformer itself. The transformers, supplied with this

  7. Giant K-doubling and in-plane/out-of-plane mixing in the asymmetric methyl-bending bands of CH3SH

    NASA Astrophysics Data System (ADS)

    Guislain, B. G.; Reid, E. M.; Lees, R. M.; Xu, Li-Hong; Twagirayezu, S.; Perry, D. S.; Thapaliya, B. P.; Dawadi, M. B.; Billinghurst, B. E.

    2017-05-01

    In analyzing high-resolution spectra of the methyl-deformation bands of methyl mercaptan recorded at the Canadian Light Source synchrotron, we have encountered interesting interactions between certain levels of the ν4 in-plane asymmetric CH3-bending mode and its ν10 out-of-plane bending partner below. The origin of the K = 0A ν4 substate is just 0.2 cm-1 higher than that of the K = 2A ν10 substate, while the K = 0E ν4 origin is only 0.035 cm-1 below the K = 2E ν10 origin. These very close accidental near-degeneracies lead to substantial perturbations in the spectrum. For the former, the A+/A- asymmetry K-doublet coupling rules are such that the A- component of the 2A ν10 doublet interacts and mixes strongly with the 0A+ ν4 levels whereas the 2A+ component is unaffected. The 2A- levels are pushed rapidly downwards by the coupling creating an extremely large apparent K = 2A asymmetry splitting. We call this "giant K-doubling" by analogy with a comparable phenomenon seen for methanol. The 0A+ ν4 state, in turn, is perturbed upward and passes through the descending K = 1A+ ν4 state between J = 22 and 23, leading to distinct local perturbations near the level-crossing. The 0E ν4 and 2E ν10 coupling produces a correspondingly strong repulsion and mixing between those two substates, and gives rise to a forbidden K = 0 ← 3E intermode sub-band in the spectrum via intensity borrowing.

  8. Irvine Smart Grid Demonstration, a Regional Smart Grid Demonstration Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yinger, Robert; Irwin, Mark

    ISGD was a comprehensive demonstration that spanned the electricity delivery system and extended into customer homes. The project used phasor measurement technology to enable substation-level situational awareness, and demonstrated SCE’s next-generation substation automation system. It extended beyond the substation to evaluate the latest generation of distribution automation technologies, including looped 12-kV distribution circuit topology using URCIs. The project team used DVVC capabilities to demonstrate CVR. In customer homes, the project evaluated HAN devices such as smart appliances, programmable communicating thermostats, and home energy management components. The homes were also equipped with energy storage, solar PV systems, and a number ofmore » energy efficiency measures (EEMs). The team used one block of homes to evaluate strategies and technologies for achieving ZNE. A home achieves ZNE when it produces at least as much renewable energy as the amount of energy it consumes annually. The project also assessed the impact of device-specific demand response (DR), as well as load management capabilities involving energy storage devices and plug-in electric vehicle charging equipment. In addition, the ISGD project sought to better understand the impact of ZNE homes on the electric grid. ISGD’s SENet enabled end-to-end interoperability between multiple vendors’ systems and devices, while also providing a level of cybersecurity that is essential to smart grid development and adoption across the nation. The ISGD project includes a series of sub-projects grouped into four logical technology domains: Smart Energy Customer Solutions, Next-Generation Distribution System, Interoperability and Cybersecurity, and Workforce of the Future. Section 2.3 provides a more detailed overview of these domains.« less

  9. Giant K-doubling and in-plane/out-of-plane mixing in the asymmetric methyl-bending bands of CH 3SH

    DOE PAGES

    Guislain, B. G.; Reid, E. M.; Lees, R. M.; ...

    2017-03-02

    In analyzing high-resolution spectra of the methyl-deformation bands of methyl mercaptan recorded at the Canadian Light Source synchrotron, we have encountered interesting interactions between certain levels of the ν 4 in-plane asymmetric CH 3-bending mode and its ν 10 out-of-plane bending partner below. The origin of the K = 0A ν 4 substate is just 0.2 cm -1 higher than that of the K = 2A ν 10 substate, while the K = 0E ν 4 origin is only 0.035 cm -1 below the K = 2E ν 10 origin. These very close accidental near-degeneracies lead to substantial perturbations inmore » the spectrum. For the former, the A +/A - asymmetry K-doublet coupling rules are such that the A - component of the 2A ν 10 doublet interacts and mixes strongly with the 0A + ν 4 levels whereas the 2A + component is unaffected. The 2A - levels are pushed rapidly downwards by the coupling creating an extremely large apparent K = 2A asymmetry splitting. We call this “giant K-doubling” by analogy with a comparable phenomenon seen for methanol. The 0A + ν 4 state, in turn, is perturbed upward and passes through the descending K = 1A + ν 4 state between J = 22 and 23, leading to distinct local perturbations near the level-crossing. The 0E ν 4 and 2E ν 10 coupling produces a correspondingly strong repulsion and mixing between those two substates, and gives rise to a forbidden K = 0 ← 3E intermode sub-band in the spectrum via intensity borrowing.« less

  10. Giant K-doubling and in-plane/out-of-plane mixing in the asymmetric methyl-bending bands of CH 3SH

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guislain, B. G.; Reid, E. M.; Lees, R. M.

    In analyzing high-resolution spectra of the methyl-deformation bands of methyl mercaptan recorded at the Canadian Light Source synchrotron, we have encountered interesting interactions between certain levels of the ν 4 in-plane asymmetric CH 3-bending mode and its ν 10 out-of-plane bending partner below. The origin of the K = 0A ν 4 substate is just 0.2 cm -1 higher than that of the K = 2A ν 10 substate, while the K = 0E ν 4 origin is only 0.035 cm -1 below the K = 2E ν 10 origin. These very close accidental near-degeneracies lead to substantial perturbations inmore » the spectrum. For the former, the A +/A - asymmetry K-doublet coupling rules are such that the A - component of the 2A ν 10 doublet interacts and mixes strongly with the 0A + ν 4 levels whereas the 2A + component is unaffected. The 2A - levels are pushed rapidly downwards by the coupling creating an extremely large apparent K = 2A asymmetry splitting. We call this “giant K-doubling” by analogy with a comparable phenomenon seen for methanol. The 0A + ν 4 state, in turn, is perturbed upward and passes through the descending K = 1A + ν 4 state between J = 22 and 23, leading to distinct local perturbations near the level-crossing. The 0E ν 4 and 2E ν 10 coupling produces a correspondingly strong repulsion and mixing between those two substates, and gives rise to a forbidden K = 0 ← 3E intermode sub-band in the spectrum via intensity borrowing.« less

  11. Phosphorylation of rat brain purified mitochondrial Voltage-Dependent Anion Channel by c-Jun N-terminal kinase-3 modifies open-channel noise.

    PubMed

    Gupta, Rajeev

    2017-09-02

    The drift kinetic energy of ionic flow through single ion channels cause vibrations of the pore walls which are observed as open-state current fluctuations (open-channel noise) during single-channel recordings. Vibration of the pore wall leads to transitions among different conformational sub-states of the channel protein in the open-state. Open-channel noise analysis can provide important information about the different conformational sub-state transitions and how biochemical modifications of ion channels would affect their transport properties. It has been shown that c-Jun N-terminal kinase-3 (JNK3) becomes activated by phosphorylation in various neurodegenerative diseases and phosphorylates outer mitochondrion associated proteins leading to neuronal apoptosis. In our earlier work, JNK3 has been reported to phosphorylate purified rat brain mitochondrial voltage-dependent anion channel (VDAC) in vitro and modify its conductance and opening probability. In this article we have compared the open-state noise profile of the native and the JNK3 phosphorylated VDAC using Power Spectral Density vs frequency plots. Power spectral density analysis of open-state noise indicated power law with average slope value α ≈1 for native VDAC at both positive and negative voltage whereas average α value < 0.5 for JNK3 phosphorylated VDAC at both positive and negative voltage. It is proposed that 1/f 1 power law in native VDAC open-state noise arises due to coupling of ionic transport and conformational sub-states transitions in open-state and this coupling is perturbed as a result of channel phosphorylation. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Occupational exposure to electric fields and induced currents associated with 400 kV substation tasks from different service platforms.

    PubMed

    Korpinen, Leena H; Elovaara, Jarmo A; Kuisti, Harri A

    2011-01-01

    The aim of the study was to investigate the occupational exposure to electric fields, average current densities, and average total contact currents at 400 kV substation tasks from different service platforms (main transformer inspection, maintenance of operating device of disconnector, maintenance of operating device of circuit breaker). The average values are calculated over measured periods (about 2.5 min). In many work tasks, the maximum electric field strengths exceeded the action values proposed in the EU Directive 2004/40/EC, but the average electric fields (0.2-24.5 kV/m) were at least 40% lower than the maximum values. The average current densities were 0.1-2.3 mA/m² and the average total contact currents 2.0-143.2 µA, that is, clearly less than the limit values of the EU Directive. The average values of the currents in head and contact currents were 16-68% lower than the maximum values when we compared the average value from all cases in the same substation. In the future it is important to pay attention to the fact that the action and limit values of the EU Directive differ significantly. It is also important to take into account that generally, the workers' exposure to the electric fields, current densities, and total contact currents are obviously lower if we use the average values from a certain measured time period (e.g., 2.5 min) than in the case where exposure is defined with only the help of the maximum values. © 2010 Wiley-Liss, Inc.

  13. Satellite-based quantification of the bottom trawling induced sediment resuspension over an entire shelf

    NASA Astrophysics Data System (ADS)

    Oberle, F. J.; Cheriton, O. M.; Hanebuth, T. J. J.

    2014-12-01

    The effect of bottom trawling activities on continental shelves has been a topic of interest for both fishery resource studies and ecological impact studies for a while. However, the impact of demersal fishing gear was almost exclusively studied from a perspective of its effects on benthic fauna, but recently it has also attracted attention due to its profound impact on sediments. Here we present the first study to quantify the trawling-induced sediment resuspension effect by combining satellite-based spatial patterns of bottom trawling with quantitative measurements of induced sediment plumes. This study examined high-resolution GPS vessel monitoring data from one year (2011-2012) to quantify the sedimentary budget caused by bottom trawling activity for the entire NW Iberian shelf, an area that is widely affected by chronic (continuous and intensive) commercial bottom trawling and is exemplary for many other narrow shelves worldwide. By filtering the GPS data by vessel type, vessel speed, and geometry of the trawl path, we resolved geographically detailed bottom trawling activities with varying local trawling intensities depending both on legal restrictions and bedrock geomorphology. Initial results show that trawling-induced resuspended sediments mark a significant if not dominant factor for a source to sink sedimentary budget, as they are calculated to be approximately two times as large as fluvial sedimentary input to the shelf. Ultimately, these results not only allow for a trawling affected sediment budget but also significantly help with marine management decisions by allowing to predict the mobilization and transport of sediment caused by bottom trawling gear at the level of a specific fishing fleet or ecosystem.

  14. Remote sensing estimation of colored dissolved organic matter (CDOM) in optically shallow waters

    NASA Astrophysics Data System (ADS)

    Li, Jiwei; Yu, Qian; Tian, Yong Q.; Becker, Brian L.

    2017-06-01

    It is not well understood how bottom reflectance of optically shallow waters affects the algorithm performance of colored dissolved organic matters (CDOM) retrieval. This study proposes a new algorithm that considers bottom reflectance in estimating CDOM absorption from optically shallow inland or coastal waters. The field sampling was conducted during four research cruises within the Saginaw River, Kawkawlin River and Saginaw Bay of Lake Huron. A stratified field sampling campaign collected water samples, determined the depth at each sampling location and measured optical properties. The sampled CDOM absorption at 440 nm broadly ranged from 0.12 to 8.46 m-1. Field sample analysis revealed that bottom reflectance does significantly change water apparent optical properties. We developed a CDOM retrieval algorithm (Shallow water Bio-Optical Properties algorithm, SBOP) that effectively reduces uncertainty by considering bottom reflectance in shallow waters. By incorporating the bottom contribution in upwelling radiances, the SBOP algorithm was able to explain 74% of the variance of CDOM values (RMSE = 0.22 and R2 = 0.74). The bottom effect index (BEI) was introduced to efficiently separate optically shallow and optically deep waters. Based on the BEI, an adaptive approach was proposed that references the amount of bottom effect in order to identify the most suitable algorithm (optically shallow water algorithm [SBOP] or optically deep water algorithm [QAA-CDOM]) to improve CDOM estimation (RMSE = 0.22 and R2 = 0.81). Our results potentially help to advance the capability of remote sensing in monitoring carbon pools at the land-water interface.

  15. Acoustic Moorings for Integrated Cetacean-Prey Studies

    DTIC Science & Technology

    2015-09-30

    Acoustic Recording Package ( HARP ), consisting of data logger and battery cases, and a hydrophone for passive acoustic monitoring of cetaceans (Wiggins...Hildebrand 2007). The HARPs will be able to record continuously at high enough bandwidth to monitor the full acoustic repertoire of cetaceans...likely to occur in the area. The HARP will be mounted near the bottom of the mooring at approximately 1,000 m depth. The HARPs are made in-house at the

  16. 20 CFR 631.19 - Appeals.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... training plans or modifications) shall apply to final disapproval of substate plans under § 631.50(f) of...' Benefits EMPLOYMENT AND TRAINING ADMINISTRATION, DEPARTMENT OF LABOR PROGRAMS UNDER TITLE III OF THE JOB TRAINING PARTNERSHIP ACT Additional Title III Administrative Standards and Procedures § 631.19 Appeals...

  17. 75 FR 39241 - Hooper Springs Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-08

    ... Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Intent to prepare an Environmental Impact Statement (EIS) and notice of floodplain and wetlands involvement. SUMMARY: BPA intends to... (collectively referred to as the Hooper Springs Project). The new BPA substation would be called Hooper Springs...

  18. 9. Photocopy of Reinforced Concrete Details drawing (from the BPA ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    9. Photocopy of Reinforced Concrete Details drawing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 6, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  19. 78 FR 60273 - Granby Pumping Plant Switchyard-Windy Gap Substation Transmission Line Rebuild, Grand County...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-01

    ... marketing administration in the U.S. Department of Energy (DOE), owns and operates the 69-kilovolt (kV... the project. No new sources of power would be needed for the project. The resource mix would not be...

  20. 2. ENVIRONMENT, FROM SOUTHEAST, SHOWING B&P INTERLOCKING TOWER, AUXILIARY INTERLOCKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    2. ENVIRONMENT, FROM SOUTHEAST, SHOWING B&P INTERLOCKING TOWER, AUXILIARY INTERLOCKING BUILDING, AND POWER SUBSTATION - Baltimore & Potomac Interlocking Tower, Adjacent to AMTRAK railroad tracks in block bounded by Howard Street, Jones Falls Expressway, Maryland Avenue & Falls Road, Baltimore, Independent City, MD

  1. 30 CFR 77.1103 - Flammable liquids; storage.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... storage tanks shall be mounted securely on firm foundations. Outlet piping shall be provided with flexible connections or other special fittings to prevent adverse effects from tank settling. (c) Fuel lines shall be... hazards. (d) Areas surrounding flammable-liquid storage tanks and electric substations and transformers...

  2. 50. Photocopy of photograph, April 27, 1937. VIEW OF POWER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    50. Photocopy of photograph, April 27, 1937. VIEW OF POWER HOUSE AND SUBSTATION DURING FLOOD. (Courtesy of the Potomac Edison Company Library (Hagerstown, MD), Historical Data Files, Dam No. 5 listing) - Dam No. 5 Hydroelectric Plant, On Potomac River, Hedgesville, Berkeley County, WV

  3. State and Substate Estimates of Nonmedical Use of Prescription Pain Relievers

    MedlinePlus

    ... of NSDUH's strengths is the stability of its survey design, which allows for multiple years of data to ... 204,000 respondents aged 12 or older. The Survey collects data by administering ... in Research Triangle Park, North Carolina. (RTI International is a ...

  4. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... lines. When it is necessary to deenergize equipment or lines for protection of employees, the... performed by designated employees. (2) Precaution shall be taken to prevent accidental operation of relays... removed for construction purposes, a temporary fence affording similar protection when the site is...

  5. 29 CFR 1926.957 - Construction in energized substations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... lines. When it is necessary to deenergize equipment or lines for protection of employees, the... performed by designated employees. (2) Precaution shall be taken to prevent accidental operation of relays... removed for construction purposes, a temporary fence affording similar protection when the site is...

  6. Oil leakage detection for electric power equipment based on ultraviolet fluorescence effect

    NASA Astrophysics Data System (ADS)

    Zhang, Jing; Wang, Jian-hui; Xu, Bin; Huang, Zhi-dong; Huang, Lan-tao

    2018-03-01

    This paper presents a method to detect the oil leakage of high voltage power equipment based on ultraviolet fluorescence effect. The method exploits the principle that the insulating oil has the fluorescent effect under the irradiation of specific ultraviolet light. The emission spectrum of insulating oil under excitation light with different wavelengths is measured and analyzed first. On this basis, a portable oil leakage detective device for high voltage power equipment is designed and developed with a selected 365 nm ultraviolet as the excitation light and the low light level camera as the fluorescence image collector. Then, the feasibility of the proposed method and device in different conditions is experimentally verified in the laboratory environment. Finally, the developed oil leakage detective device is applied to 500 kV Xiamen substation and Quanzhou substation. And the results show that the device can detect the oil leakage of high voltage electrical equipment quickly and conveniently even under the condition of a slight oil leakage especially in the low light environment.

  7. Collaborative Defense of Transmission and Distribution Protection and Control Devices Against Cyber Attacks (CODEF) DE-OE0000674. ABB Inc. Final Scientific/Technical Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nuqui, Reynaldo

    This report summarizes the activities conducted under the DOE-OE funded project DEOE0000674, where ABB Inc. (ABB), in collaboration with University of Illinois at Urbana-Champaign (UIUC), Bonneville Power Administration (BPA), and Ameren-Illinois (Ameren-IL) pursued the development of a system of collaborative defense of electrical substation’s intelligent electronic devices against cyber-attacks (CODEF). An electrical substation with CODEF features will be more capable of mitigating cyber-attacks especially those that seek to control switching devices. It leverages the security extensions of IEC 61850 to empower existing devices to collaborate in identifying and blocking malicious intents to trip circuit breakers, mis-coordinate devices settings, even thoughmore » the commands and the measurements comply with correct syntax. The CODEF functions utilize the physics of electromagnetic systems, electric power engineering principles, and computer science to bring more in depth cyber defense closer to the protected substation devices.« less

  8. Phosphorylation of an intrinsically disordered segment in Ets1 shifts conformational sampling toward binding-competent substates.

    PubMed

    Bui, Jennifer M; Gsponer, Jörg

    2014-08-05

    Functions of many proteins are affected by posttranslational modifications of intrinsically disordered (ID) regions, yet little is known about the underlying molecular mechanisms. By combining molecular dynamics simulations and protein docking, we demonstrate that the addition of phosphates to an ID segment adjacent to the PNT domain of Ets1 directs conformational sampling toward substates that are most compatible with high-affinity binding of the TAZ1 domain of its coactivator CBP. The phosphate charges disrupt salt bridges and thereby open a hydrophobic cleft and expose hydrophobic residues at the ID N terminus. The structure of the PNT-TAZ1 complex that we determined shows that PNT binds to TAZ1 via these hydrophobic regions in a similar manner to how it interacts with other partners. Our calculations reveal a dual effect of phosphorylation in that it changes the dynamics of PNT so that it becomes more compatible for TAZ1 binding and increases complementarity with this binding partner. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Lessons Learned "Establishing an Electrically Safe Work Condition" Specifically related to Racking Electrical Breakers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martinez, Tommy Robert; Romero, Philbert Roland; Garcia, Samuel Anthony

    During low voltage electrical equipment maintenance, a bad breaker was identified. The breaker was racked out from the substation cubicle without following the hazardous energy control process identified in the Integrated Work Document (IWD). The IWD required the substation to be in an electrically safe work condition prior to racking the breaker. Per NFPA 70E requirements, electrical equipment shall be put into an electrically safe work condition before an employee performs work on or interacts with equipment in a manner that increases the likelihood of creating an arc flash. Racking in or out a breaker on an energized bus maymore » increase the likelihood of creating an arc flash dependent on equipment conditions. A thorough risk assessment must be performed prior to performing such a task. The risk assessment determines the risk control measures to be put in place prior to performing the work. Electrical Safety Officers (ESO) can assist in performing risk assessments and incorporating risk control measures.« less

  10. Hypothesized diprotomeric enzyme complex supported by stochastic modelling of palytoxin-induced Na/K pump channels

    PubMed Central

    Vilallonga, Gabriel D.; de Almeida, Antônio-Carlos G.; Ribeiro, Kelison T.; Campos, Sergio V. A.

    2018-01-01

    The sodium–potassium pump (Na+/K+ pump) is crucial for cell physiology. Despite great advances in the understanding of this ionic pumping system, its mechanism is not completely understood. We propose the use of a statistical model checker to investigate palytoxin (PTX)-induced Na+/K+ pump channels. We modelled a system of reactions representing transitions between the conformational substates of the channel with parameters, concentrations of the substates and reaction rates extracted from simulations reported in the literature, based on electrophysiological recordings in a whole-cell configuration. The model was implemented using the UPPAAL-SMC platform. Comparing simulations and probabilistic queries from stochastic system semantics with experimental data, it was possible to propose additional reactions to reproduce the single-channel dynamic. The probabilistic analyses and simulations suggest that the PTX-induced Na+/K+ pump channel functions as a diprotomeric complex in which protein–protein interactions increase the affinity of the Na+/K+ pump for PTX. PMID:29657808

  11. Study on Earthquake Response of High Voltage Electrical Equipment Coupling System with Flexible Busbar

    NASA Astrophysics Data System (ADS)

    Liu, Chuncheng; Qu, Da; Wang, Chongyang; Lv, Chunlei; Li, Guoqiang

    2017-12-01

    With the rapid development of technology and society, all walks of life in China are becoming more and more dependent on power systems. When earthquake occurs, the electrical equipment of substation is prone to damage because of its own structural features, top-heavy, and brittleness of main body. At the same time, due to the complex coupling of the soft electrical connection of substation electrical equipment, the negative impact can not be estimated. In this paper, the finite element model of the coupling system of the single unit of high voltage electrical equipment with the connecting soft bus is established and the seismic response is analysed. The results showed that there is a significant difference between the simple analysis for the seismic response of electrical equipment monomer and the analytical results of electrical equipment systems, and the impact on different electrical equipment is different. It lays a foundation for the future development of seismic performance analysis of extra high voltage electrical equipment.

  12. Structure-Function Perturbation and Dissociation of Tetrameric Urate Oxidase by High Hydrostatic Pressure

    PubMed Central

    Girard, Eric; Marchal, Stéphane; Perez, Javier; Finet, Stéphanie; Kahn, Richard; Fourme, Roger; Marassio, Guillaume; Dhaussy, Anne-Claire; Prangé, Thierry; Giffard, Marion; Dulin, Fabienne; Bonneté, Françoise; Lange, Reinhard; Abraini, Jacques H.; Mezouar, Mohamed; Colloc'h, Nathalie

    2010-01-01

    Abstract Structure-function relationships in the tetrameric enzyme urate oxidase were investigated using pressure perturbation. As the active sites are located at the interfaces between monomers, enzyme activity is directly related to the integrity of the tetramer. The effect of hydrostatic pressure on the enzyme was investigated by x-ray crystallography, small-angle x-ray scattering, and fluorescence spectroscopy. Enzymatic activity was also measured under pressure and after decompression. A global model, consistent with all measurements, discloses structural and functional details of the pressure-induced dissociation of the tetramer. Before dissociating, the pressurized protein adopts a conformational substate characterized by an expansion of its substrate binding pocket at the expense of a large neighboring hydrophobic cavity. This substate should be adopted by the enzyme during its catalytic mechanism, where the active site has to accommodate larger intermediates and product. The approach, combining several high-pressure techniques, offers a new (to our knowledge) means of exploring structural and functional properties of transient states relevant to protein mechanisms. PMID:20483346

  13. Multipole mixing ratios and substate populations in Rn-219

    NASA Astrophysics Data System (ADS)

    Jones, G. D.

    2016-08-01

    Historical alpha-gamma angular correlation data for the decay of 223Ra into excited states of 219Rn have been analysed, using the correct spins of the states involved, for the first time. The analyses produced multipole mixing ratios (E2/M1) of δ (144)=-0.11\\+/- 0.03, δ (154)=0, δ (158)=-0.205\\+/- 0.018 and δ (269)=-0.149\\+/- 0.004 where the nominal transition energies, in keV, are given in brackets. These values are consistent with published values obtained from internal conversion electron spectroscopy. It is also found that δ (324)=0 and δ (338)=-0.235\\+/- 0.030 (where both values differ from current tabulations) and that the sign of the multipole mixing ratio for the 122 keV transition is negative. The 158, 269 and 338 keV states are found to be aligned with high population of M=+/- 3/2 substates and the 127 keV state is believed to have undergone spin relaxation.

  14. Probing RNA Native Conformational Ensembles with Structural Constraints.

    PubMed

    Fonseca, Rasmus; van den Bedem, Henry; Bernauer, Julie

    2016-05-01

    Noncoding ribonucleic acids (RNA) play a critical role in a wide variety of cellular processes, ranging from regulating gene expression to post-translational modification and protein synthesis. Their activity is modulated by highly dynamic exchanges between three-dimensional conformational substates, which are difficult to characterize experimentally and computationally. Here, we present an innovative, entirely kinematic computational procedure to efficiently explore the native ensemble of RNA molecules. Our procedure projects degrees of freedom onto a subspace of conformation space defined by distance constraints in the tertiary structure. The dimensionality reduction enables efficient exploration of conformational space. We show that the conformational distributions obtained with our method broadly sample the conformational landscape observed in NMR experiments. Compared to normal mode analysis-based exploration, our procedure diffuses faster through the experimental ensemble while also accessing conformational substates to greater precision. Our results suggest that conformational sampling with a highly reduced but fully atomistic representation of noncoding RNA expresses key features of their dynamic nature.

  15. Hydrologic monitoring of selected streams in coal fields of central and southern Utah; summary of data collected, August 1978-September 1984

    USGS Publications Warehouse

    Price, Don; Plantz, G.G.

    1987-01-01

    The U.S. Geological Survey conducted a coal-hydrology monitoring program in coal-field areas of central and southern Utah during August 1978-September 1984 to determine possible hydrologic impacts of future mining and to provide a better understanding of the hydrologic systems of the coal resource areas monitored. Data were collected at 19 gaging stations--18 stations in the Price, San Rafael, and Dirty Devil River basins, and 1 in the Kanab Creek Basin. Streamflow data were collected continuously at 11 stations and seasonally at 5 stations. At the other three stations streamflow data were collected continuously during the 1979 water year and then seasonally for the rest of their periods of record. Types of data collected at each station included quantity and quality of streamflow; suspended sediment concentrations; and descriptions of stream bottom sediments, benthic invertebrate, and phytoplankton samples. Also, base flow measurements were made annually upstream from 12 of the gaging stations. Stream bottom sediment sampled at nearly all the monitoring sites contained small to moderate quantities of coal, which may be attributed chiefly to pre-monitoring mining. Streamflow sampled at several sites contained large concentrations of sulfate and dissolved solids. Also, concentrations of various trace elements at 10 stations, and phenols at 18 stations, exceeded the criteria of the EPA for drinking water. This may be attributed to contemporary (water years 1979-84) mine drainage activities. The data collected during the complete water years (1979-84) of monitoring do provide a better understanding of the hydrologic systems of the coal field areas monitored. The data also provide a definite base by which to evaluate hydrologic impacts of continued or increased coal mining in those areas. (Author 's abstract)

  16. Near-bottom hydrophone measurements of ambient noise and sperm whale vocalizations in the northern Gulf of Mexico

    NASA Astrophysics Data System (ADS)

    Newcomb, Joal; Fisher, Robert; Field, Robert; Turgut, Altan; Ioup, George; Ioup, Juliette; Rayborn, Grayson; Kuczaj, Stan; Caruthers, Jerald; Goodman, Ralph; Sidorovskaia, Natalia

    2002-05-01

    Three bottom-moored hydrophones, 50 m above the bottom, were placed on a downslope line, ending at the largest concentration of sperm whale sightings in the northern Gulf of Mexico, in 600 m, 800 m, and 1000 m water depths. These depths were chosen after upslope propagation modeling, using historical databases, showed transmission losses greater than 110 dB at hydrophones near the bottom in water shallower than 600 m for a 500 m deep source at the 1000 m contour. These autonomously recording hydrophones were environmental acoustic recording system (EARS) buoys obtained from the Naval Oceanographic Office. They were capable of recording signals up to 5500 Hz continuously for 36 days and were deployed from July 17 through August 21. During this period a major marine mammal exercise was being conducted at the surface by the Minerals Management Service and the National Marine Fisheries Service, with other government and university scientists, in which temporary acoustic recording devices were attached to the whales and the whales were monitored by a surface towed array. Our near-bottom measurements of ambient noise and sperm whale vocalizations are discussed and compared to those surface and on-whale measurements. [Research supported by ONR.

  17. Assessing prey fish populations in Lake Michigan: Comparison of simultaneous acoustic-midwater trawling with bottom trawling

    USGS Publications Warehouse

    Fabrizio, Mary C.; Adams, Jean V.; Curtis, Gary L.

    1997-01-01

    The Lake Michigan fish community has been monitored since the 1960s with bottom trawls, and since the late 1980s with acoustics and midwater trawls. These sampling tools are limited to different habitats: bottom trawls sample fish near bottom in areas with smooth substrates, and acoustic methods sample fish throughout the water column above all substrate types. We compared estimates of fish densities and species richness from daytime bottom trawling with those estimated from night-time acoustic and midwater trawling at a range of depths in northeastern Lake Michigan in summer 1995. We examined estimates of total fish density as well as densities of alewife Alosa pseudoharengus (Wilson), bloater Coregonus hoyi (Gill), and rainbow smelt Osmerus mordax (Mitchell) because these three species are the dominant forage of large piscivores in Lake Michigan. In shallow water (18 m), we detected more species but fewer fish (in fish/ha and kg/ha) with bottom trawls than with acoustic-midwater trawling. Large aggregations of rainbow smelt were detected by acoustic-midwater trawling at 18 m and contributed to the differences in total fish density estimates between gears at this depth. Numerical and biomass densitites of bloaters from all depths were significantly higher when based on bottom trawl samples than on acoustic-midwater trawling, and this probably contributed to the observed significant difference between methods for total fish densities (kg/ha) at 55 m. Significantly fewer alewives per ha were estimated from bottom trawling than from acoustics-midwater trawling at 55 m, and in deeper waters, no alewives were taken by bottom trawling. The differences detected between gears resulted from alewife, bloater, and rainbow smelt vertical distributions, which varied with lake depth and time of day. Because Lake Michigan fishes are both demersal and pelagic, a single sampling method cannot be used to completely describe characteristics of the fish community.

  18. Sediment Sampling in Estuarine Mudflats with an Aerial-Ground Robotic Team

    PubMed Central

    Deusdado, Pedro; Guedes, Magno; Silva, André; Marques, Francisco; Pinto, Eduardo; Rodrigues, Paulo; Lourenço, André; Mendonça, Ricardo; Santana, Pedro; Corisco, José; Almeida, Susana Marta; Portugal, Luís; Caldeira, Raquel; Barata, José; Flores, Luis

    2016-01-01

    This paper presents a robotic team suited for bottom sediment sampling and retrieval in mudflats, targeting environmental monitoring tasks. The robotic team encompasses a four-wheel-steering ground vehicle, equipped with a drilling tool designed to be able to retain wet soil, and a multi-rotor aerial vehicle for dynamic aerial imagery acquisition. On-demand aerial imagery, properly fused on an aerial mosaic, is used by remote human operators for specifying the robotic mission and supervising its execution. This is crucial for the success of an environmental monitoring study, as often it depends on human expertise to ensure the statistical significance and accuracy of the sampling procedures. Although the literature is rich on environmental monitoring sampling procedures, in mudflats, there is a gap as regards including robotic elements. This paper closes this gap by also proposing a preliminary experimental protocol tailored to exploit the capabilities offered by the robotic system. Field trials in the south bank of the river Tagus’ estuary show the ability of the robotic system to successfully extract and transport bottom sediment samples for offline analysis. The results also show the efficiency of the extraction and the benefits when compared to (conventional) human-based sampling. PMID:27618060

  19. Using GIS to appraise structural control of the river bottom morphology near hydrotechnical objects on Alluvial rivers

    NASA Astrophysics Data System (ADS)

    Habel, Michal; Babinski, Zygmunt; Szatten, Dawid

    2017-11-01

    The paper presents the results of analyses of structural changes of the Vistula River bottom, in a section of direct influence of the bridge in Torun (Northern Poland) fitted with one pier in the form of a central island. The pier limits a free water flow by reducing the active width of the riverbed by 12%. In 2011, data on the bottom morphology was collected, i.e. before commencing bridge construction works, throughout the whole building period - 38 measurements. Specific river depth measurements are carried out with SBES and then bathymetric maps are drawn up every two months. The tests cover the active Vistula river channel of 390 - 420 metres in width, from 730+40 to 732+30 river kilometre. The paper includes the results of morphometric analyses of vertical and horizontal changes of the river bottom surrounded by the bridge piers. The seasonality of scour holes and inclination of accumulative forms (sand bars) in the relevant river reach was analysed. Morphometric analyses were performed on raster bases with GIS tools, including the Map Algebra algorithm. The obtained results shown that scour holes/pools of up to 10 metres in depth and exceeding 1200 metres in length are formed in the tested river segment. Scour holes within the pier appeared in specific periods. Constant scour holes were found at the riverbank, and the rate of their movement down the river was 0.6 to 1.3 m per day. The tests are conducted as part of a project ordered by the City of Torun titled `Monitoring Hydrotechniczny Inwestycji Mostowej 2011 - 2014' (Hydrotechnical Monitoring of the Bridge Investment, period 2011 - 2014).

  20. Additional deployment of ocean bottom gravity meter and ocean bottom electro-magnetic meter for the multidisciplinary cabled observation in Sagami Bay, Japan

    NASA Astrophysics Data System (ADS)

    Mitsuzawa, K.; Goto, T.; Araki, E.; Watanabe, T.; Sugioka, H.; Kasaya, T.; Sayanagi, K.; Mikada, H.; Fujimoto, H.; Nagao, T.; Koizumi, K.; Asakawa, K.

    2005-12-01

    Western part of the Sagami Bay central Pacific side of Japan, is known as one of the high active tectonic areas. In this area, Teishi Knoll, volcanic seamount, erupted in 1989 and the earthquake swarms occurs repeatedly every few years in the eastern coast of the Izu Peninsula. The real-time deep sea floor observatory was deployed about 7 km off Hatsushima Island, Sagami Bay, at a depth of 1174 m in 1993 to monitor seismic activities, underwater pressure, water temperature and deep currents. The video camera and lights were also mounted in the observatory to monitor the relations among biological activities associated with the tectonic activities. The observation system including submarine electro-optical cable with a length of 8 km was completely renewed in 2000. The several underwater-mateable connectors are installed in the new observatory for additional observation instruments. A precise pressure sensor, ocean bottom gravity meter and ocean bottom electro-magnetic meter were installed using ROV Hyper-Dolphin in the cruise of R/V Natsushima from January 9 to 14, 2005. We start to operate them at February 10, 2005 after checking those of data qualities. We also installed an underwater internet interface, which is called Linux Box, as a prototype of underwater network system which was operated by Linux operating system. The Linux Box is a key network system for multidisciplinary observation network. It will be able to connect much kind of observation instruments as using internet connection. We put the precise pressure sensor as a sensor of the Linux Box in this experiment.

  1. Extraction of Seabed/Subsurface Features in a Potential CO2 Sequestration Site in the Southern Baltic Sea, Using Wavelet Transform of High-resolution Sub-Bottom Profiler Data

    NASA Astrophysics Data System (ADS)

    Tegowski, J.; Zajfert, G.

    2014-12-01

    Carbon Capture & Storage (CCS) efficiently prevents the release of anthropogenic CO2 into the atmosphere. We investigate a potential site in the Polish Sector of the Baltic Sea (B3 field site), consisting in a depleted oil and gas reservoir. An area ca. 30 x 8 km was surveyed along 138 acoustic transects, realised from R/V St. Barbara in 2012 and combining multibeam echosounder, sidescan sonar and sub-bottom profiler. Preparation of CCS sites requires accurate knowledge of the subsurface structure of the seafloor, in particular deposit compactness. Gas leaks in the water column were monitored, along with the structure of upper sediment layers. Our analyses show the shallow sub-seabed is layered, and quantified the spatial distribution of gas diffusion chimneys and seabed effusion craters. Remote detection of gas-containing surface sediments can be rather complex if bubbles are not emitted directly into the overlying water and thus detectable acoustically. The heterogeneity of gassy sediments makes conventional bottom sampling methods inefficient. Therefore, we propose a new approach to identification, mapping, and monitoring of potentially gassy surface sediments, based on wavelet analysis of echo signal envelopes of a chirp sub-bottom profiler (EdgeTech SB-0512). Each echo envelope was subjected to wavelet transformation, whose coefficients were used to calculate wavelet energies. The set of echo envelope parameters was input to fuzzy logic and c-means algorithms. The resulting classification highlights seafloor areas with different subsurface morphological features, which can indicate gassy sediments. This work has been conducted under EC FP7-CP-IP project No. 265847: Sub-seabed CO2 Storage: Impact on Marine Ecosystems (ECO2).

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luczkovich, J.J.; Wagner, T.W.; Michalek, J.L.

    In order to monitor changes caused by local and global human actions to a coral reef ecosystem, we sea-truthed a natural color Landsat TM image prepared for a coastal region of the northwestern Dominican Republic and recorded average water depth, precise geographical positions, and bottom types (seagrass, 15 sites; coral reef, ten sites; and sand, six sites). There were no significant differences in depth for the bottom type groups. The depths ranged from 0 to 16.1 m. Mean digital counts of seagrass and coral reef sites did not differ significantly in any band. A multivariate analysis of variance using allmore » three bands gave similar results. A ratio of the green/blue bands (TM 2/TM 1) showed there was a spectral shift associated with increasing depth, but not bottom type. Due to small-scale patchiness, seagrass and coral areas were difficult to distinguish, but sandy areas can be distinguished using Landsat TM imagery and our methods. 12 refs.« less

  3. Hydrogeomorphic controls on hyporheic and riparian transport in two headwater mountain streams during base flow recession

    NASA Astrophysics Data System (ADS)

    Ward, Adam S.; Schmadel, Noah M.; Wondzell, Steven M.; Harman, Ciaran; Gooseff, Michael N.; Singha, Kamini

    2016-02-01

    Solute transport along riparian and hyporheic flow paths is broadly expected to respond to dynamic hydrologic forcing by streams, aquifers, and hillslopes. However, direct observation of these dynamic responses is lacking, as is the relative control of geologic setting as a control on responses to dynamic hydrologic forcing. We conducted a series of four stream solute tracer injections through base flow recession in each of two watersheds with contrasting valley morphology in the H.J. Andrews Experimental Forest, monitoring tracer concentrations in the stream and in a network of shallow riparian wells in each watershed. We found hyporheic mean arrival time, temporal variance, and fraction of stream water in the bedrock-constrained valley bottom and near large roughness elements in the wider valley bottom were not variable with discharge, suggesting minimal control by hydrologic forcing. Conversely, we observed increases in mean arrival time and temporal variance and decreasing fraction stream water with decreasing discharge near the hillslopes in the wider valley bottom. This may indicate changes in stream discharge and valley bottom hydrology control transport in less constrained locations. We detail five hydrogeomorphic responses to base flow recession to explain observed spatial and temporal patterns in the interactions between streams and their valley bottoms. Models able to account for the transition from geologically dominated processes in the near-stream subsurface to hydrologically dominated processes near the hillslope will be required to predict solute transport and fate in valley bottoms of headwater mountain streams.

  4. 40 CFR 256.65 - Recommendations for public participation.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 25 2011-07-01 2011-07-01 false Recommendations for public... Participation § 256.65 Recommendations for public participation. (a) State and substate planning agencies should establish an advisory group, or utilize an existing group, to provide recommendations on major policy and...

  5. 75 FR 27550 - Electrical Interconnection of the Juniper Canyon I Wind Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-17

    ... Canyon I Wind Project AGENCY: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Availability of Record of Decision (ROD). SUMMARY: The Bonneville Power Administration (BPA... County, Washington. To interconnect the Wind Project, BPA will expand an existing substation (Rock Creek...

  6. 76 FR 63294 - Combined Notice of Filings #1

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-12

    ... that the Commission received the following electric rate filings: Docket Numbers: ER11-3812-001... Time on Monday, October 24, 2011. Docket Numbers: ER12-11-000. Applicants: Nevada Power Company. Description: Nevada Power Company submits tariff filing per 35.12: Rate Schedule No. 123 Merchant Substation...

  7. 75 FR 7231 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-18

    ... Business Service (RBS) through Rural Development State and sub-State offices serving each State. Need and Use of the Information: RBS will collect information to determine a lender and borrower eligibility and creditworthiness. The information is used by RBS loan officers and approval officials to determine...

  8. 77 FR 14416 - Notice of Availability of a Final Environmental Impact Statement and Final Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-09

    ... wind turbine generators; a substation; administration, operations and maintenance facilities... Action (the ``Refined Project''). Under the Refined Project configuration, only 112 wind turbines... Report for the Pattern Energy Group's Ocotillo Express Wind Energy Project and Proposed California Desert...

  9. Patterns of State-Regional Cooperation in Nebraska.

    ERIC Educational Resources Information Center

    Bansal, Prem Lata

    This study empirically explores patterns of authority delegation by Nebraska state agencies to substate regional organizations and evaluates the effectiveness of those patterns in realizing the goals of decentralization. Information about the field operations and role perceptions of various state agencies was gathered through use of a…

  10. Supplement Analysis for the Transmission System Vegetation Management Program FEIS (DOE/EIS-0285/SA-81)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howington, John

    2002-07-09

    BPA proposes total vegetation management (bare ground) in the electrical substations, and, noxious weed management and maintenance of landscaping within the property boundaries of the listed facilities. These facilities are all located within The Dalles District of the Redmond Region.

  11. Tsunami process: From upper mantle to atmosphere

    NASA Astrophysics Data System (ADS)

    Ershov, S.; Mikhaylovskaya, I.; Novik, O.

    Earthquakes in near sea regions and/or tsunamis are manifestations of powerful geodynamic processes beneath the Ocean floor (75 % of the Earth' surface). An effective monitoring of these large-scale processes is not possible without satellites as well as without understanding of physical nature of signals accompanying these processes, e.g. connection between parameters of a seismic excitation in ocean lithosphere and electromagnetic (EM) signals in atmosphere. Basing on the theory of elasticity, electrodynamics, fluid dynamics and geophysical data we formulate a nonlinear mathematical model of generation and propagation of seismo-EM signals in the basin of a marginal sea including transfer of seismic and EM energy from upper mantle to hydrosphere and EM emission into atmosphere up to ionosphere domain D. For a model basin approximately similar to the central part of the Sea of Japan, we calculate signals caused by moderate elastic displacements (EDs): the ampl of a few cm, the main freq. 0.01-10 Hz and duration up to 10 sec (by runs with different acceptable data) which are supposed to be arising at the moment t=0 at the bottom of the upper mantle layer M. The EM signal appears near the bottom of the conductive (0.02 S/m) layer M and reaches for the sea bottom by t=3.5 sec with the ampl. Of 50 pT. This signal propagate in sea water (4 S/m) rather slowly and seems to be "frozen": its front is located near the sea bottom and is replicating the bottom's configuration up to the moment (t=5.2 sec) of the seismic P wave (from M) arrival at the sea bottom. The EM field is generated in seismically disturbed sea water in presence of the geomagnetic field" a specific structure of a seismo-hydrodynamic flow, a spatial break of the diffusive magnetic field, joining of its contours, and other details of the seismo-hydro-EM tsunami process are shown to clear out the out the physical nature of its signals. By the moderate EDs (above), the magnetic signal (freq. 0.01-10 Hz, i.e. the same as the EDs' freq.) is of order of a few hundreds of pT at the ocean-atmosphere interface and of order of a few tens of hydrodynamic wave's amplitude far from the shore is too small (20 cm) and EM observations are needed to discover this threatening wave. The computed signals' characteristics are of orders observed. The recommendations for the EM monitoring (at a sea bottom, surface, and atmosphere) of seismic excitations in ocean lithosphere and tsunamis are given.

  12. The effects of stream channelization on bottom dwelling organisms : phase 1 report : 1974 construction season.

    DOT National Transportation Integrated Search

    1975-01-01

    Two streams being channelized under Department contracts have been monitored since June 1974. Suspended solids, flow, rainfall and benthic population measurements have been obtained at various times for each stream. At present, all but the benthic po...

  13. Energy Research - Sandia Energy

    Science.gov Websites

    learning process and validating the MagLIF approach. Sandia's team will also use their experimental results monitoring, to non-destructively measure the transport and composition of plant sap and products of experimental systems, at different polymer fractions, compared with corresponding SCFT calculations. Bottom

  14. Residency, movements and habitat use of adult white seabream (Diplodus sargus) between natural and artificial reefs

    NASA Astrophysics Data System (ADS)

    Abecasis, D.; Bentes, L.; Lino, P. G.; Santos, M. N.; Erzini, K.

    2013-02-01

    Artificial reefs are used as management tools for coastal fisheries and ecosystems and the knowledge of habitat use and fish movements around them is necessary to understand their performance and improve their design and location. In this study wild specimens of Diplodus sargus were tagged with acoustic tags and their movements were tracked using passive acoustic telemetry. The monitored area enclosed a natural rocky reef, an adjacent artificial reef (AR) and shallower sandy bottoms. Most of the fish were close to full time residents in the monitored area. Results revealed that D. sargus use the natural reef areas on a more frequent basis than the AR. However, excursions to the adjacent AR and sandy bottoms were frequently detected, essentially during daytime. The use of acoustic telemetry allowed a better understanding of the use of artificial reef structures and its adjacent areas by wild D. sargus providing information that is helpful towards the improvement of AR design and location.

  15. Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: towards applications in ambulatory monitoring.

    PubMed

    Lee, Jihyoung; Matsumura, Kenta; Yamakoshi, Takehiro; Rolfe, Peter; Tanaka, Naoto; Kim, Kyungho; Yamakoshi, Ken-ichi

    2013-03-01

    Normalized pulse volume (NPV) derived from the ear has the potential to be a practical index for monitoring daily life stress. However, ear NPV has not yet been validated. Therefore, we compared NPV derived from an index finger using transmission photoplethysmography as a reference, with NPV derived from a middle finger and four sites of the ear using reflection photoplethysmography during baseline and while performing cold and warm water immersion in ten young and six middle-aged subjects. The results showed that logarithmically-transformed NPV (lnNPV) during cold water immersion as compared with baseline values was significantly lower, only at the index finger, the middle finger and the bottom of the ear-canal. Furthermore, lnNPV reactivities (ΔlnNPV; the difference between baseline and test values) from an index finger were significantly related to ΔlnNPV from the middle finger and the bottom of the ear-canal (young: r = 0.90 and 0.62, middle-aged: r = 0.80 and 0.58, respectively). In conclusion, these findings show that reflection and transmission photoplethysmography are comparable methods to derive NPV in accordance with our theoretical prediction. NPV derived from the bottom of the ear-canal is a valid approach, which could be useful for evaluating daily life stress.

  16. Bias in groundwater samples caused by wellbore flow

    USGS Publications Warehouse

    Reilly, Thomas E.; Franke, O. Lehn; Bennett, Gordon D.

    1989-01-01

    Proper design of physical installations and sampling procedures for groundwater monitoring networks is critical for the detection and analysis of possible contaminants. Monitoring networks associated with known contaminant sources sometimes include an array of monitoring wells with long well screens. The purpose of this paper is: (a) to report the results of a numerical experiment indicating that significant borehole flow can occur within long well screens installed in homogeneous aquifers with very small head differences in the aquifer (less than 0.01 feet between the top and bottom of the screen); (b) to demonstrate that contaminant monitoring wells with long screens may completely fail to fulfill their purpose in many groundwater environments.

  17. Differences in Size Selectivity and Catch Composition Between Two Bottom Trawls Used in High-Arctic Surveys of Bottom Fishes, Crabs and Other Demersal Macrofauna

    NASA Astrophysics Data System (ADS)

    Lauth, R.; Norcross, B.; Kotwicki, S.; Britt, L.

    2016-02-01

    Long-term monitoring of the high-Arctic marine biota is needed to understand how the ecosystem is changing in response to climate change, diminishing sea-ice, and increasing anthropogenic activity. Since 1959, bottom trawls (BT) have been a primary research tool for investigating fishes, crabs and other demersal macrofauna in the high-Arctic. However, sampling gears, methodologies, and the overall survey designs used have generally lacked consistency and/or have had limited spatial coverage. This has restricted the ability of scientists and managers to effectively use existing BT survey data for investigating historical trends and zoogeographic changes in high-Arctic marine populations. Two different BTs currently being used for surveying the high-Arctic are: 1) a small-mesh 3-m plumb-staff beam trawl (PSBT), and 2) a large-mesh 83-112 Eastern bottom trawl (EBT). A paired comparison study was conducted in 2012 to compare catch composition and the sampling characteristics of the two different trawl gears, and a size selectivity ratio statistic was used to investigate how the probability of fish and crab retention differs between the EBT and PBST. Obvious contrasting characteristics of the PSBT and EBT were mesh size, area-swept, tow speed, and vertical opening. The finer mesh and harder bottom-tending characteristics of the PSBT retained juvenile fishes and other smaller macroinvertebrates and it was also more efficient catching benthic infauna that were just below the surface. The EBT had a larger net opening with greater tow duration at a higher speed that covered a potentially wider range of benthic habitats during a single tow, and it was more efficient at capturing larger and more mobile organisms, as well as organisms that were further off bottom. The ratio statistic indicated large differences in size selectivity between the two gears for both fish and crab. Results from this investigation will provide a framework for scientists and mangers to better understand how to interpret and compare data from existing PBST and EBT surveys in the high-Arctic, and the results provide information on factors worth considering in choosing what BT gear to use for a standardized long-term BT sampling program to monitor fishes, crabs and other demersal macrofauna in the high-Arctic.

  18. Level indicator for pressure vessels

    DOEpatents

    Not Available

    1982-04-28

    A liquid-level monitor for tracking the level of a coal slurry in a high-pressure vessel including a toroidal-shaped float with magnetically permeable bands thereon disposed within the vessel, two pairs of magnetic-field generators and detectors disposed outside the vessel adjacent the top and bottom thereof and magnetically coupled to the magnetically permeable bands on the float, and signal-processing circuitry for combining signals from the top and bottom detectors for generating a monotonically increasing analog control signal which is a function of liquid level. The control signal may be utilized to operate high-pressure control valves associated with processes in which the high-pressure vessel is used.

  19. A collapsible trap for capturing ruffe

    USGS Publications Warehouse

    Edwards, Andrew J.; Czypinski, Gary D.; Selgeby, James H.

    1998-01-01

    A modified version of the Windermere trap was designed, constructed, and tested for its effectiveness in capturing ruffe Gymnocephalus cernuus. The inexpensive, lightweight, collapsible trap was easily deployed and retrieved from a small boat. Field tests conducted at the St. Louis River estuary in western Lake Superior in spring 1995 and 1996 indicated that the trap was effective in capturing ruffe. Proportions of the ruffe in trap and bottom trawl catches were similar in 1995 and 1996. This trap could be a useful tool in surveillance, monitoring, or control programs for ruffe or similar species, either to augment existing sampling programs or especially in situations where gillnetting or bottom trawling are not feasible.

  20. 76 FR 59394 - Big Eddy-Knight Transmission Project

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-26

    ...: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION: Notice of Availability of Record... that BPA has received by increasing BPA's 500-kV transmission capability to move power from the east...-kilovolt (kV) transmission line and ancillary facilities between BPA's existing Big Eddy Substation in The...

  1. 77 FR 26275 - Bonneville Power Administration; Montana-to-Washington Transmission System Upgrade Project EIS

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-03

    ... Upgrade Project EIS AGENCY: Bonneville Power Administration (BPA), Department of Energy (DOE). ACTION... involvement. SUMMARY: BPA intends to prepare an EIS in accordance with the National Environmental Policy Act... consist of a combination of reinforcements of five existing BPA substations, placement of new conductor on...

  2. 6. Photocopy of Location, Site & Wall Sections drawing (from ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. Photocopy of Location, Site & Wall Sections drawing (from the Bonneville Power Administration Engineering Vault, Portland, Oregon, Drawing C13-J2-342-D1, Sheet 1, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  3. 77 FR 22774 - Estes to Flatiron Substation Transmission Lines Rebuild Project, Larimer County, CO

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ... Floodplain and Wetlands Involvement. SUMMARY: Western Area Power Administration currently owns and operates... floodplains and wetlands, so this Notice of Intent (NOI) also serves as a notice of proposed floodplain or wetland action in accordance with DOE floodplain and wetland environmental review requirements. DATES...

  4. 77 FR 1498 - Draft Environmental Assessment and Proposed Single-Species Habitat Conservation Plan for the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-10

    ... wind turbines and associated facilities and access roads, maintenance of the wind turbines and... include constructing and installing the wind turbines and associated electrical facilities and access... new 230- kilovolt substation (to be built on an existing pad), maintaining the new wind turbines and...

  5. 126. MOTOR CONTROL CENTER 1 (MCC1), FACING NORTH IN ROW ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    126. MOTOR CONTROL CENTER 1 (MCC-1), FACING NORTH IN ROW OF ELECTRICAL CABINETS JUST SOUTH OF TRANSFORMER SUBSTATION CABINETS IN TRANSFORMER ROOM (112), LSB (BLDG. 770) - Vandenberg Air Force Base, Space Launch Complex 3, Launch Pad 3 West, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  6. GENERAL VIEW OF PUMPHOUSE FOUNDATIONS, ALSO SHOWING THREE PUMPS STILL ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    GENERAL VIEW OF PUMPHOUSE FOUNDATIONS, ALSO SHOWING THREE PUMPS STILL ON THE PAD, AND THE ELECTRICAL SUBSTATION IN LEFT MIDDLE DISTANCE - Edwards Air Force Base, Air Force Rocket Propulsion Laboratory, Flame Deflector Water System, Test Area 1-120, north end of Jupiter Boulevard, Boron, Kern County, CA

  7. Field Trip.

    ERIC Educational Resources Information Center

    Sanders, Bill

    1993-01-01

    Reports the results of a field trip to measure the intensity of electromagnetic fields generated by electronic devices in the home, in cars, at work, outside, and in places people visit during the day. Found that a person gets more intense exposure while working at a computer than by living next to an electrical substation. (MDH)

  8. 19. DETAIL TO SOUTHEAST OF EXCITER 1 GIRARD TURBINE, SHOWING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    19. DETAIL TO SOUTHEAST OF EXCITER 1 GIRARD TURBINE, SHOWING BEVEL-GEARED REGISTER GATE CONTROLS, OLD POWERHOUSE BASEMENT - Trenton Falls Hydroelectric Station, Powerhouse & Substation, On west bank of West Canada Creek, along Trenton Falls Road, 1.25 miles north of New York Route 28, Trenton Falls, Oneida County, NY

  9. Within compound, looking northwest, Power Plant (Building 5761) and Guard ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Within compound, looking northwest, Power Plant (Building 5761) and Guard Tower (Building 5762) to left, Electrical Substation to right - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA

  10. Real-time digital data-acquisition system for determining load characteristics. Volume 2: Operating, programming and maintenance instructions

    NASA Astrophysics Data System (ADS)

    Podesto, B.; Lapointe, A.; Larose, G.; Robichaud, Y.; Vaillancourt, C.

    1981-03-01

    The design and construction of a Real-Time Digital Data Acquisition System (RTDDAS) to be used in substations for on-site recording and preprocessing load response data were included. The gathered data can be partially processed on site to compute the apparent, active and reactive powers, voltage and current rms values, and instantaneous values of phase voltages and currents. On-site processing capability is provided for rapid monitoring of the field data to ensure that the test setup is suitable. Production analysis of field data is accomplished off-line on a central computer from data recorded on a dual-density (800/1600) magnetic tape which is IBM-compatible. Parallel channels of data can be recorded at a variable rate from 480 to 9000 samples per second per channel. The RTDDAS is housed in a 9.1 m (30-ft) trailer which is shielded from electromagnetic interference and protected by isolators from switching surges. The test must sometimes be performed. Information pertaining to the installation, software operation, and maintenance is presented.

  11. Demersal and larval fish assemblages in the Chukchi Sea

    NASA Astrophysics Data System (ADS)

    Norcross, Brenda L.; Holladay, Brenda A.; Busby, Morgan S.; Mier, Kathryn L.

    2010-01-01

    A multidisciplinary research cruise was conducted in the Chukchi Sea in summer 2004 during which we investigated assemblages of small demersal fishes and ichthyoplankton and the water masses associated with these assemblages. This study establishes a baseline of 30 demersal fish and 25 ichthyoplankton taxa in US and Russian waters of the Chukchi Sea. Presence/absence of small demersal fish clustered into four assemblages: Coastal Fishes, Western Chukchi Fishes, South Central Chukchi Fishes, and North Central Chukchi Fishes. Habitats occupied by small demersal fishes were characterized by sediment type, bottom salinity, and bottom temperature. Abundance of ichthyoplankton grouped into three assemblages with geographical extent similar to that of the bottom assemblages, except that there was a single assemblage for Central Chukchi Fishes. Water-column temperature and salinity characterized ichthyoplankton habitats. Three water masses, Alaska Coastal Water, Bering Sea Water, and Winter Water, were identified from both bottom and depth-averaged water-column temperature and salinity. A fourth water mass, Resident Chukchi Water, was identified only in the bottom water. The water mass and habitat characteristics with which demersal and larval fish assemblages were associated create a baseline to measure anticipated effects of climate change that are expected to be most severe at high latitudes. Monitoring fish assemblages could be a tool for assessing the effects of climate change. Climate-induced changes in distributions of species would result in a restructuring of fish assemblages in the Chukchi Sea.

  12. Water-quality data from shallow pond-bottom groundwater in the Fishermans Cove area of Ashumet Pond, Cape Cod, Massachusetts, 2001–2010

    USGS Publications Warehouse

    McCobb, Timothy D.; LeBlanc, Denis R.

    2011-01-01

    The U.S. Geological Survey (USGS) collected water-quality data between 2001 and 2010 in the Fishermans Cove area of Ashumet Pond, Falmouth, Massachusetts, where the eastern portion of a treated-wastewater plume, created by more than 60 years of overland disposal, discharges to the pond. Temporary drive points were installed, and shallow pond-bottom groundwater was sampled, at 167 locations in 2001, 150 locations in 2003, and 120 locations in 2004 to delineate the distribution of wastewater-related constituents. In 2004, the Air Force Center for Engineering and the Environment (AFCEE) installed a pond-bottom permeable reactive barrier (PRB) to intercept phosphate in the plume at its discharge point to the pond. The USGS monitored the performance of the PRB by collecting samples from temporary drive points at multiple depth intervals in 2006 (200 samples at 76 locations) and 2009 (150 samples at 90 locations). During the first 5 years after installation of the PRB, water samples were collected periodically from five types of pore-water samplers that had been permanently installed in and near the PRB during the barrier's emplacement. The distribution of wastewater-related constituents in the pond-bottom groundwater and changes in the geochemistry of the pond-bottom groundwater after installation of the PRB have been documented in several published reports that are listed in the references.

  13. A method for evaluating the evolution of clogging: application to the Pampulha Campus infiltration system (Brazil).

    PubMed

    Barraud, S; Gonzalez-Merchan, C; Nascimento, N; Moura, P; Silva, A

    2014-01-01

    In order to evaluate the hydraulic performance of stormwater infiltration trenches, a study was undertaken to assess clogging and its distribution between the bottom and the sides. The method used was based on the calibration of the hydraulic resistance event by event according to Bouwer's model and applied to a demonstration trench in Belo-Horizonte monitored in the framework of the European Project Switch. The calibration was performed by minimizing the distance between measured and modeled infiltration flow rates and by using continuous measurements of rainfall, inflow, water temperature and depth in the trench. The study showed that the methodology and particularly Bouwer's model was able to produce satisfactory results. It revealed a significant clogging evolution within a year, with global resistance increasing by a factor of 9. A significant difference between the bottom and the sides was observed; the bottom being more rapidly prone to clogging. Sudden fluctuations of the hydraulic resistance of the bottom were found that could be explained by very high concentrations of total suspended solids from inflows (about 2,000 mg/L). Clogging of the sides evolves over the time but with a very low rate.

  14. 50 CFR 217.225 - Requirements for monitoring and reporting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... usual (i.e., 12-16 hours). (C) The number of observers shall be increased and/or positions changed to...-based), observer name and location, climate and weather conditions, and tidal conditions; (B... measurements shall be taken to ensure that hydrophones do not drag on the bottom during tidal changes. (v...

  15. Drivers, mechanisms and long term variability of bottom seasonal hypoxia in the Black Sea north-western Shelf. Is there any recovery after eutrophication ?

    NASA Astrophysics Data System (ADS)

    Capet, Arthur; Beckers, Jean-Marie; Grégoire, Marilaure

    2013-04-01

    The Black Sea North-western shelf (NWS) is a shallow eutrophic area in which seasonal stratification of the water column isolates bottom waters from the atmosphere and prevents ventilation to compensate for the large consumption of oxygen, due to respiration in the bottom waters and in the sediments. A 3D coupled physical biogeochemical model is used to investigate the dynamics of bottom hypoxia in the Black Sea NWS at different temporal scales from seasonal to interannual (1981-2009) and to differentiate the driving factors (climatic versus eutrophication) of hypoxic conditions in bottom waters. Model skills are evaluated by comparison with 14500 in-situ oxygen measurements available in the NOAA World Ocean Database and the Black Sea Commission data. The choice of skill metrics and data subselections orientate the validation procedure towards specific aspects of the oxygen dynamics, and prove the model's ability to resolve the seasonal cycle and interannual variability of oxygen concentration as well as the spatial location of the oxygen depleted waters and the specific threshold of hypoxia. During the period 1981-2009, each year exhibits seasonal bottom hypoxia at the end of summer. This phenomenon essentially covers the northern part of the NWS, receiving large inputs of nutrients from the Danube, Dniestr and Dniepr rivers, and extends, during the years of severe hypoxia, towards the Romanian Bay of Constanta. In order to explain the interannual variability of bottom hypoxia and to disentangle its drivers, a statistical model (multiple linear regression) is proposed using the long time series of model results as input variables. This statistical model gives a general relationships that links the intensity of hypoxia to eutrophication and climate related variables. The use of four predictors allows to reproduce 78% of hypoxia interannual variability: the annual nitrate discharge (N), the sea surface temperature in the month preceding stratification (T ), the amount of semi-labile organic matter in the sediments (C) and the duration of the stratification (D). Eutrophication (N,C) and climate (T ,D) predictors explain a similar amount of variability (~ 35%) when considered separately. A typical timescale of 9.3 years is found to describe the inertia of sediments in the recovering process after eutrophication. From this analysis, we find that under standard conditions (i.e. average atmospheric conditions, sediments in equilibrium with river discharges), the intensity of hypoxia can be linked to the level of nitrate discharge through a non-linear equation (power law). Bottom hypoxia does not affect the whole Black Sea NWS but rather exhibits an important spatial variability. This heterogeneous distribution, in addition to the seasonal fluctuations, complicates the monitoring of bottom hypoxia leading to contradictory conclusions when the interpretation is done from different sets of data. We find that it was the case after 1995 when the recovery process was overestimated due to the use of observations concentrated in areas and months not typically affected by hypoxia. This stresses out the urging need of a dedicated monitoring effort in the NWS of the Black Sea focused on the areas and the period of the year concerned by recurrent hypoxic events.

  16. Garden Banks 388 deepwater production riser structural and environmental monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thrall, D.E.; Pokladnik, R.L.

    1995-12-01

    A deepwater production riser, to be installed in 1995 in Garden Banks 388 in the Gulf of Mexico, has been instrumented with bonded resistance strain gages so that the remaining operational fatigue life can be quantified. The riser supports flowlines from subsea oil and gas wells to a floating combination drilling/production vessel, and thus is fixed at its lower end and free to move at its upper terminus. The distribution of bending stresses throughout the riser, which is attached to a template at 2,096 foot depth and extends to within 150 feet of the surface, reaches a maximum at themore » bottom. The riser is instrumented with strain gages, inclinometers, and accelerometers at five locations along its length so that tension, bending, orientation, and motion of the riser can be monitored at these locations, including the bottom joint. Correlation of the riser response data with the excitation or environmental data, including wave motion, current velocities, wind velocities, and vessel mooring tensions and positions is enhanced by acquiring and archiving all data on a single common system having multiple redundant elements for reliability. This paper describes the production riser structural and environmental monitoring system used on the Garden Banks 388 project.« less

  17. Improving marine disease surveillance through sea temperature monitoring, outlooks and projections

    PubMed Central

    Maynard, Jeffrey; van Hooidonk, Ruben; Harvell, C. Drew; Eakin, C. Mark; Liu, Gang; Willis, Bette L.; Williams, Gareth J.; Dobson, Andrew; Heron, Scott F.; Glenn, Robert; Reardon, Kathleen; Shields, Jeffrey D.

    2016-01-01

    To forecast marine disease outbreaks as oceans warm requires new environmental surveillance tools. We describe an iterative process for developing these tools that combines research, development and deployment for suitable systems. The first step is to identify candidate host–pathogen systems. The 24 candidate systems we identified include sponges, corals, oysters, crustaceans, sea stars, fishes and sea grasses (among others). To illustrate the other steps, we present a case study of epizootic shell disease (ESD) in the American lobster. Increasing prevalence of ESD is a contributing factor to lobster fishery collapse in southern New England (SNE), raising concerns that disease prevalence will increase in the northern Gulf of Maine under climate change. The lowest maximum bottom temperature associated with ESD prevalence in SNE is 12°C. Our seasonal outlook for 2015 and long-term projections show bottom temperatures greater than or equal to 12°C may occur in this and coming years in the coastal bays of Maine. The tools presented will allow managers to target efforts to monitor the effects of ESD on fishery sustainability and will be iteratively refined. The approach and case example highlight that temperature-based surveillance tools can inform research, monitoring and management of emerging and continuing marine disease threats. PMID:26880840

  18. Improving marine disease surveillance through sea temperature monitoring, outlooks and projections.

    PubMed

    Maynard, Jeffrey; van Hooidonk, Ruben; Harvell, C Drew; Eakin, C Mark; Liu, Gang; Willis, Bette L; Williams, Gareth J; Groner, Maya L; Dobson, Andrew; Heron, Scott F; Glenn, Robert; Reardon, Kathleen; Shields, Jeffrey D

    2016-03-05

    To forecast marine disease outbreaks as oceans warm requires new environmental surveillance tools. We describe an iterative process for developing these tools that combines research, development and deployment for suitable systems. The first step is to identify candidate host-pathogen systems. The 24 candidate systems we identified include sponges, corals, oysters, crustaceans, sea stars, fishes and sea grasses (among others). To illustrate the other steps, we present a case study of epizootic shell disease (ESD) in the American lobster. Increasing prevalence of ESD is a contributing factor to lobster fishery collapse in southern New England (SNE), raising concerns that disease prevalence will increase in the northern Gulf of Maine under climate change. The lowest maximum bottom temperature associated with ESD prevalence in SNE is 12 °C. Our seasonal outlook for 2015 and long-term projections show bottom temperatures greater than or equal to 12 °C may occur in this and coming years in the coastal bays of Maine. The tools presented will allow managers to target efforts to monitor the effects of ESD on fishery sustainability and will be iteratively refined. The approach and case example highlight that temperature-based surveillance tools can inform research, monitoring and management of emerging and continuing marine disease threats. © 2016 The Authors.

  19. 33. VIEW OF FOUR OF SEVEN MONITORS SUSPENDED FROM CEILING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    33. VIEW OF FOUR OF SEVEN MONITORS SUSPENDED FROM CEILING OF SLC-3W CONTROL ROOM NEAR NORTH WALL. LEFT TO RIGHT ABOVE THE MONITORS: DIGITAL GREENWICH MEAN TIME CLOCK, COMPLEX SAFETY WARNING LIGHTS FOR SLC-3W (PAD-2) AND LOB (THE GREEN LIGHT ON THE BOTTOM OF EACH STACK IS ILLUMINATED), AND DIGITAL COUNTDOWN AND HOLD CLOCKS. LEFT TO RIGHT BELOW THE MONITORS: INDICATOR LIGHTS SHOWING WHICH PAD OR VEHICLE FACILITIES ARE RECEIVING POWER FROM POWER PLANT 4 ON SOUTH VAFB, LIGHTS TO INDICATE IF POWER PLANT 4 IS ON OR OFF LINE, DIGITAL COUNTDOWN CLOCK, AND MILITARY-TIME CLOCK. - Vandenberg Air Force Base, Space Launch Complex 3, Launch Operations Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA

  20. 76 FR 67670 - Basin Electric Power Cooperative, Inc.: Notice of Intent To Prepare an Environmental Impact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-11-02

    ..., modifications to 4 existing substations, a 345-kV switchyard, maintenance access roads, temporary construction... will address the construction, operation, and maintenance of Basin Electric's proposed Project. The Project includes construction, operation and maintenance of approximately 190 miles of new 345-kV single...

  1. 43 CFR 3832.34 - How may I use my mill site?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING MINING CLAIMS OR SITES Mill Sites... plants and substations; (3) Tailings ponds and leach pads; (4) Rock and soil dumps; (5) Water and process... independent mill sites for processing metallic minerals from lode claims using: (1) Quartz or stamp mills; or...

  2. 43 CFR 3832.34 - How may I use my mill site?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING MINING CLAIMS OR SITES Mill Sites... plants and substations; (3) Tailings ponds and leach pads; (4) Rock and soil dumps; (5) Water and process... independent mill sites for processing metallic minerals from lode claims using: (1) Quartz or stamp mills; or...

  3. 43 CFR 3832.34 - How may I use my mill site?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... MANAGEMENT, DEPARTMENT OF THE INTERIOR MINERALS MANAGEMENT (3000) LOCATING MINING CLAIMS OR SITES Mill Sites... plants and substations; (3) Tailings ponds and leach pads; (4) Rock and soil dumps; (5) Water and process... independent mill sites for processing metallic minerals from lode claims using: (1) Quartz or stamp mills; or...

  4. Job Grading Standard for Electric Power Controller WG-5407.

    ERIC Educational Resources Information Center

    Civil Service Commission, Washington, DC. Bureau of Policies and Standards.

    The standard is used to grade nonsupervisory jobs involved in controlling the generation or distribution of electric power. The jobs are located at power generating plants, power distribution centers, and substations. The work requires ability to anticipate load changes due to work schedules, weather, and other variables, in order to engage or cut…

  5. 75 FR 43519 - Parker-Davis Project; Transmission Capacity for Renewable Energy Between Electrical District No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-26

    ... for Renewable Energy Between Electrical District No. 5 Substation and the Palo Verde Hub AGENCY... transmission service on the P- DP for the purpose of transmitting renewable energy. Specifically, Western is soliciting interest from entities looking to transfer renewable energy from the area south of Phoenix...

  6. 10. Photocopy of Miscellaneous Details drawing showing door, window, louvre, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. Photocopy of Miscellaneous Details drawing showing door, window, louvre, stairway, roof and other detailing (from the BPA Engineering Vault, Drawing C13-J2-342-D1, Sheet 4, 13 March 1939) - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  7. 7 CFR 980.117 - Import regulations; onions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Texas points Officer-in-charge, 1301 West Expressway, Alamo, Tex. 78516. Phone 512-787-4091 or 512-787-6881 1 All Arizona points Officer-in-charge, P.O. Box 1614, Nogales, Ariz. 85621. Phone 602-287-4783 1.... Phone 213-688-2489 3 All Hawaii points Officer-in-charge, P.O. Box 22159, Pawaa Substation, Honolulu...

  8. Immigrants as New Speakers in Galicia and Wales: Issues of Integration, Belonging and Legitimacy

    ERIC Educational Resources Information Center

    Bermingham, Nicola; Higham, Gwennan

    2018-01-01

    Immigrant integration in nation states increasingly focuses on the importance of learning the national state language. This is evidenced by increased emphasis on rigorous language testing and tighter citizenship regulations. This paper analyses immigrant integration in two sub-state contexts, Galicia and Wales, where presence of a national…

  9. Environmental assessment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-08-01

    The proposed overhead power line construction project (Sand Dunes to Ochoa, in Eddy and Lea Counties, New Mexico) will supply additional electric power to the Waste Isolation Pilot Plant (WIPP) and involve construction of a new electric substation at WIPP. This would provide a redundant electrical power source to WIPP. A finding of no significant impact is made.

  10. 15. ELECTRICAL REACTOR SHELVES, CONSTRUCTED OF CONCRETE IN THE BASEMENT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    15. ELECTRICAL REACTOR SHELVES, CONSTRUCTED OF CONCRETE IN THE BASEMENT ALONG EAST WALL, WITH REACTOR PADS BEHIND FRAMED AND SCREENED CAGE, AND PORCELAIN-LINED CABLE DUCTS VISIBLE IN WALL NEAR FLOOR AT REAR - Bonneville Power Administration South Bank Substation, I-84, South of Bonneville Dam Powerhouse, Bonneville, Multnomah County, OR

  11. SPERTI plot plan for control area. Includes Control Building (PER601), ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SPERT-I plot plan for control area. Includes Control Building (PER-601), Gate House (PER-603), well sand settling tank, substation, and septic system. Date: February 1955. INEEL index no. 760-0101-00-396-109104 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID

  12. 76 FR 40390 - Notice of Availability of a Draft Land Use Plan Amendment, Environmental Impact Statement and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-08

    ..., 474 megawatt (MW) wind energy project including 158 wind turbine generators, a substation... Environmental Impact Report for the Pattern Energy Group Ocotillo Express Wind Energy Project, Imperial County... Statement (EIS) and Draft Environmental Impact Report (EIR) for the Ocotillo Express Wind Energy Project...

  13. 6. A VIEW TOWARD THE EAST SIDE OF BUILDING NO. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    6. A VIEW TOWARD THE EAST SIDE OF BUILDING NO. 1, SHOWING THE OFFICE SECTION AT THE SOUTHEAST CORNER. BUILDING NO. 18 (ENGINEERING BUILDING) IS VISIBLE IN THE CENTER DISTANCE, AND BUILDING NO. 12 (OFFICE/SUBSTATION) AT THE RIGHT. - United Engineering Company Shipyard, 2900 Main Street, Alameda, Alameda County, CA

  14. The Return to Attrition: Warfare in the Late Nation-State Era

    DTIC Science & Technology

    2007-12-01

    a confluence of sub-state tension and regional economic inter- penetration that will act like spark and tinder for regional conflict. The main...tolerance for loss on a given issue increasing the lengths the power will go to protect its interest. Those areas with both spark and dry tinder should be

  15. 75 FR 44008 - Revised Notice of Intent To Prepare an Environmental Impact Statement for the Proposed Boardman...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-27

    ... Prepare an Environmental Impact Statement for the Proposed Boardman to Hemingway 500 Kilovolt Transmission..., intend to prepare an Environmental Impact Statement (EIS) for the Boardman to Hemingway (B2H) Project... for construction by IPC between the existing Hemingway substation, located near Melba in Owyhee County...

  16. 42. Photocopy of photograph, c. 1930. DETAIL OF 33,000 VOLT ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    42. Photocopy of photograph, c. 1930. DETAIL OF 33,000 VOLT HIGH TENSION SUBSTATION AND STEP UP TRANSFORMERS. (From the collection of the files of Mr. Tony Robucci, Supervisor for Minor Stations, Potomac Edison Company, Hagerstown, MD) - Dam No. 5 Hydroelectric Plant, On Potomac River, Hedgesville, Berkeley County, WV

  17. Design, Development, and Commissioning of a Substation Automation Laboratory to Enhance Learning

    ERIC Educational Resources Information Center

    Thomas, M. S.; Kothari, D. P.; Prakash, A.

    2011-01-01

    Automation of power systems is gaining momentum across the world, and there is a need to expose graduate and undergraduate students to the latest developments in hardware, software, and related protocols for power automation. This paper presents the design, development, and commissioning of an automation lab to facilitate the understanding of…

  18. 78 FR 4165 - Notice of Availability of the Draft Environmental Impact Statement for the Arturo Mine Project...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-18

    ... office, substation and associated power transmission lines, water wells, water distribution and sewer...; access; discharges to surface water; air quality (including mercury); and impacts to stream drainages... which may impact water resources, and the Elko County Board of Commissioners have raised concerns about...

  19. NORTH AND WEST SIDES OF OIL HOUSE IN RIGHT FOREGROUND, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    NORTH AND WEST SIDES OF OIL HOUSE IN RIGHT FOREGROUND, WITH EMBANKMENT (MI-100-A) IN LEFT FOREGROUND, AND POWERHOUSE (MI-100-B) AND SUBSTATION (MI-100-C) AT CENTER AND LEFT BACKGROUND. VIEW TO SOUTHEAST - Hardy Hydroelectric Plant, Oil House, 6928 East Thirty-sixth Street, Newaygo, Newaygo County, MI

  20. Tornadoes and transmission reliability planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Teles, J.E.; Anderson, S.W.; Landgren, G.L.

    1980-01-01

    The objective of this paper is to introduce an analytical approach for predicting overhead transmission line outages that are caused by tornadoes. The method is presently being used to determine the effects of tornadoes on various right-of-way configurations associated with a generating station project or the supply to a major substation. 2 refs.

  1. 77 FR 10475 - Tri-State Generation and Transmission Association, Inc., Notice of Intent To Hold Public Scoping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-22

    ... Assessment (EA) to meet its responsibilities under the National Environmental Policy Act (NEPA) and RUS's... proposed Burlington-Wray 230-kilovolt (kV) Transmission Project (Proposal) consists of the following: a proposed new single-circuit 230-kV electric transmission line between the existing Burlington Substation in...

  2. Model-centric distribution automation: Capacity, reliability, and efficiency

    DOE PAGES

    Onen, Ahmet; Jung, Jaesung; Dilek, Murat; ...

    2016-02-26

    A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditionalmore » system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.« less

  3. Elliptic Curve Cryptography-Based Authentication with Identity Protection for Smart Grids

    PubMed Central

    Zhang, Liping; Tang, Shanyu; Luo, He

    2016-01-01

    In a smart grid, the power service provider enables the expected power generation amount to be measured according to current power consumption, thus stabilizing the power system. However, the data transmitted over smart grids are not protected, and then suffer from several types of security threats and attacks. Thus, a robust and efficient authentication protocol should be provided to strength the security of smart grid networks. As the Supervisory Control and Data Acquisition system provides the security protection between the control center and substations in most smart grid environments, we focus on how to secure the communications between the substations and smart appliances. Existing security approaches fail to address the performance-security balance. In this study, we suggest a mitigation authentication protocol based on Elliptic Curve Cryptography with privacy protection by using a tamper-resistant device at the smart appliance side to achieve a delicate balance between performance and security of smart grids. The proposed protocol provides some attractive features such as identity protection, mutual authentication and key agreement. Finally, we demonstrate the completeness of the proposed protocol using the Gong-Needham- Yahalom logic. PMID:27007951

  4. Elliptic Curve Cryptography-Based Authentication with Identity Protection for Smart Grids.

    PubMed

    Zhang, Liping; Tang, Shanyu; Luo, He

    2016-01-01

    In a smart grid, the power service provider enables the expected power generation amount to be measured according to current power consumption, thus stabilizing the power system. However, the data transmitted over smart grids are not protected, and then suffer from several types of security threats and attacks. Thus, a robust and efficient authentication protocol should be provided to strength the security of smart grid networks. As the Supervisory Control and Data Acquisition system provides the security protection between the control center and substations in most smart grid environments, we focus on how to secure the communications between the substations and smart appliances. Existing security approaches fail to address the performance-security balance. In this study, we suggest a mitigation authentication protocol based on Elliptic Curve Cryptography with privacy protection by using a tamper-resistant device at the smart appliance side to achieve a delicate balance between performance and security of smart grids. The proposed protocol provides some attractive features such as identity protection, mutual authentication and key agreement. Finally, we demonstrate the completeness of the proposed protocol using the Gong-Needham-Yahalom logic.

  5. Model-centric distribution automation: Capacity, reliability, and efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onen, Ahmet; Jung, Jaesung; Dilek, Murat

    A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditionalmore » system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.« less

  6. Free energy landscape of the Michaelis complex of lactate dehydrogenase: A network analysis of atomistic simulations

    NASA Astrophysics Data System (ADS)

    Pan, Xiaoliang; Schwartz, Steven

    2015-03-01

    It has long been recognized that the structure of a protein is a hierarchy of conformations interconverting on multiple time scales. However, the conformational heterogeneity is rarely considered in the context of enzymatic catalysis in which the reactant is usually represented by a single conformation of the enzyme/substrate complex. Lactate dehydrogenase (LDH) catalyzes the interconversion of pyruvate and lactate with concomitant interconversion of two forms of the cofactor nicotinamide adenine dinucleotide (NADH and NAD+). Recent experimental results suggest that multiple substates exist within the Michaelis complex of LDH, and they are catalytic competent at different reaction rates. In this study, millisecond-scale all-atom molecular dynamics simulations were performed on LDH to explore the free energy landscape of the Michaelis complex, and network analysis was used to characterize the distribution of the conformations. Our results provide a detailed view of the kinetic network the Michaelis complex and the structures of the substates at atomistic scale. It also shed some light on understanding the complete picture of the catalytic mechanism of LDH.

  7. Design and development of 500 m long HTS cable system in the KEPCO power grid, Korea

    NASA Astrophysics Data System (ADS)

    Sohn, S. H.; Lim, J. H.; Yang, B. M.; Lee, S. K.; Jang, H. M.; Kim, Y. H.; Yang, H. S.; Kim, D. L.; Kim, H. R.; Yim, S. W.; Won, Y. J.; Hwang, S. D.

    2010-11-01

    In Korea, two long-term field demonstrations for high temperature superconducting (HTS) cable have been carried out for several years; Korea Electric Power Corporation (KEPCO) and LS Cable Ltd. (LSC) independently. Encouraged at the result of the projects performed in parallel, a new project targeting the real grid operation was launched in the fourth quarter of 2008 with the Korean government's financial support. KEPCO and LSC are jointly collaborating in the selection of substation, determination of cable specification, design of cryogenic system, and the scheme of protection coordination. A three phase 500 m long HTS cable at a distribution level voltage of 22.9 kV is to be built at 154/22.9 kV Icheon substation located in near Seoul. A hybrid cryogenic system reflecting the contingency plan is being designed including cryocoolers. The HTS cable system will be installed in the second quarter of 2010, being commissioned by the fall of 2010. This paper describes the objectives of the project and design issues of the cable and cryogenic system in detail.

  8. Development of Voltage Regulation Plan by Composing Subsystem with the SFES for DC On-line Electric Vehicle

    NASA Astrophysics Data System (ADS)

    Jung, S.; Lee, J. H.; Yoon, M.; Lee, H.; Jang, G.

    The study of the application process of the relatively small size 'Superconducting Flywheel Energy Storage (SFES)' system is conducted to regulate voltage fluctuation of the DC On-Line Electric Vehicle (OLEV) system, which is designed by using DC power system network. It is recommended to construct the power conversion system nearby the substation because the charging system is under the low voltage. But as the system is usually built around urban area and it makes hard to construct the subsystems at every station, voltage drop can occur in power supply inverter that is some distance from the substation. As the alternative of this issue, DC distribution system is recently introduced and has possibility to solve the above issue. In this paper, SFES is introduced to solve the voltage drop under the low voltage distribution system by using the concept of the proposed DC OLEV which results in building the longer distance power supply system. The simulation to design the SFES by using DC power flow analysis is carried out and it is verified in this paper.

  9. Reconstruction of Power Supply System 20 kV Distribution to Compare Power Rate and Fall Voltage PT. PLN (Persero) Area Dumai

    NASA Astrophysics Data System (ADS)

    Tanjung, Abrar; Monice

    2017-12-01

    Electricity in Bagan Siapi city fire is channeled through a feeder distribution system of 20 kV. The main supply of Bagan Siapi-api city comes from PLTD unit Bagan Siapi fire which is  ± 1.5 kms from the load center and Duri Substation is  ± 102 kms from Bagan Siapi-api city through Hubung Ujung Tanjung. The long distances between the Duri Mainstation and Bagan Siapiapi city resulted in a 14.85 kV end-voltage and a 988.7 kW loss. Voltage losses resulted in ineffective service to the consumer and large network power losses being uneconomical for power delivery operations. The result of end voltage calculation is 10.42 kV and the power loss is 988.7 kW. After the New Substation operates, reconfiguration-1 produces the lowest end-voltage calculation of 16.21 kV and a power loss of 136.59 kW, while reconfiguration-2 produces a low end stress calculation of 17.37 kV and a power loss of 56.93 kW.

  10. Conformational fluctuations in a green fluorescent protein-like Akane family protein: a high-pressure fluorescence study at 0.1-700 MPa

    NASA Astrophysics Data System (ADS)

    Maeno, Akihiro; Kato, Yuko; Jimbo, Mitsuru; Amada, Kei; Mita, Hajime; Akasaka, Kazuyuki

    2017-04-01

    We have investigated conformational fluctuations in a new green fluorescent protein(GFP)-like protein rb-Akane found in a red-brown-colored octocoral, Scleronephthya gracillima (Kuekenthal)), with high pressure fluorescence spectroscopy at 0.1-700 MPa. Besides the green fluorescence at 510 nm, two red fluorescence peaks are observed at 590 and 629 nm, the relative intensity of which varies reversibly with pressure. The phenomenon is interpreted as representing the cis-trans isomerization of the chromophore accompanied by the conformational transition between two sub-states of the red fluorescence form of rb-Akane. The two sub-states are separated only marginally in free energy (ΔG0 = 1.9 ± 0.4 kJ mol-1), but significantly in partial molar volume (ΔV0 = -19.8 ± 1.4 ml mol-1) at 0.1 MPa (pH 7.5, 25°C). Above 500 MPa, the fluorescence at λmax 629 nm undergoes another reversible change with pressure, showing the onset of unfolding.

  11. Electronic transitions of tantalum monofluoride

    NASA Astrophysics Data System (ADS)

    Ng, K. F.; Zou, Wenli; Liu, Wenjian; Cheung, A. S.-C.

    2017-03-01

    The electronic transition spectrum of the tantalum monofluoride (TaF) molecule in the spectral region between 448 and 560 nm has been studied using the technique of laser-ablation/reaction free jet expansion and laser induced fluorescence spectroscopy. The TaF molecule was produced by reacting laser-ablated tantalum atoms with sulfur hexafluoride gas seeded in argon. Twenty-two vibrational bands with resolved rotational structure have been recorded and analyzed, which were organized into seven electronic transitions. The X3Σ-(0+) state has been identified to be the ground state and the determined equilibrium bond length, re, and vibrational frequency, ωe, are 1.8184 Å and 700.1 cm-1, respectively. The low-lying Λ-S states and Ω sub-states of TaF were also theoretically studied at the MRCISD+Q level of theory with spin-orbit coupling. The Ω = 0+ and 2 sub-states from the -3Σ and 3Φ state have been found to be the ground and the first excited states, respectively, which agrees well with our experimental determinations. This work represents the first experimental investigation of the molecular structure of the TaF molecule.

  12. Free energy surface of the Michaelis complex of lactate dehydrogenase: a network analysis of microsecond simulations.

    PubMed

    Pan, Xiaoliang; Schwartz, Steven D

    2015-04-30

    It has long been recognized that the structure of a protein creates a hierarchy of conformations interconverting on multiple time scales. The conformational heterogeneity of the Michaelis complex is of particular interest in the context of enzymatic catalysis in which the reactant is usually represented by a single conformation of the enzyme/substrate complex. Lactate dehydrogenase (LDH) catalyzes the interconversion of pyruvate and lactate with concomitant interconversion of two forms of the cofactor nicotinamide adenine dinucleotide (NADH and NAD(+)). Recent experimental results suggest that multiple substates exist within the Michaelis complex of LDH, and they show a strong variance in their propensity toward the on-enzyme chemical step. In this study, microsecond-scale all-atom molecular dynamics simulations were performed on LDH to explore the free energy landscape of the Michaelis complex, and network analysis was used to characterize the distribution of the conformations. Our results provide a detailed view of the kinetic network of the Michaelis complex and the structures of the substates at atomistic scales. They also shed light on the complete picture of the catalytic mechanism of LDH.

  13. Photovoltaic Hosting Capacity of Feeders with Reactive Power Control and Tap Changers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ceylan, Oğuzhan; Paudyal, Sumit; Bhattarai, Bishnu P.

    This paper proposes an algorithm to determine photovoltaic (PV) hosting capacity of power distribution networks as a function of number of PV injection nodes, reactive power support from the PVs, and the sub-station load tap changers (LTCs). In the proposed method, several minute by minute simulations are run based on randomly chosen PV injection nodes, daily PV output profiles, and daily load profiles from a pool of high-resolution realistic data set. The simulation setup is built using OpenDSS and MATLAB. The performance of the proposed method is investigated in the IEEE 123-node distribution feeder for multiple scenarios. The case studiesmore » are performed particularly for one, two, five and ten PV injection nodes, and looking at the maximum voltage deviations. Case studies show that the PV hosting capacity of the 123-node feeder greatly differs with the number of PV injection nodes. We have also observed that the PV hosting capacity increases with reactive power support and higher tap position of sub-station LTC.« less

  14. Continuous seismic monitoring of Nishinoshima volcano, Izu-Ogasawara, by using long-term ocean bottom seismometers

    NASA Astrophysics Data System (ADS)

    Shinohara, Masanao; Ichihara, Mie; Sakai, Shin'ichi; Yamada, Tomoaki; Takeo, Minoru; Sugioka, Hiroko; Nagaoka, Yutaka; Takagi, Akimichi; Morishita, Taisei; Ono, Tomozo; Nishizawa, Azusa

    2017-11-01

    Nishinoshima in Izu-Ogasawara started erupting in November 2013, and the island size increased. Continuous monitoring is important for study of the formation process. Since it is difficult to make continuous observations on a remote uninhabited island, we started seismic observations near Nishinoshima using ocean bottom seismometers (OBSs) from February 2015. Our OBSs have a recording period of 1 year, and recovery and re-deployment of OBSs were repeated to make continuous observations. The OBSs were deployed with distances of less than 13 km from the crater. Events with particular characteristics were frequently recorded during the eruption period and are estimated to correlate with the release of plumes from the crater by comparison with temporal on-site records using a video camera and microphones. We estimated the number of events using the amplitude average of records to monitor volcanic activity. There were approximately 1800 detected events per day from February to July 2015. The number started to decrease from July 2015, and reached less than 100 per day in November 2015. The surface activity of the volcano was estimated to have ceased in November 2015. Characteristic events began re-occurring in the middle of April 2017. The number of events reached approximately 1400 events per day at the end of May 2017. Seafloor seismic observations using OBSs are a powerful tool for continuous monitoring of island volcanic activity.[Figure not available: see fulltext.

  15. Propagation and Signal Modeling

    NASA Astrophysics Data System (ADS)

    Jensen, Finn B.

    The use of sound in the sea is ubiquitous: Apart from the military aspect of trying to detect an adversary’s mines and submarines, ship-mounted sonars measure water depth, ship speed, and the presence of fish shoals. Side-scan systems are used for mapping the bottom topography, sub-bottom profilers for getting information about the deeper layering, and other sonar systems for locating pipelines and cables on the seafloor. Sound is also used for navigating submerged vehicles, for underwater communications and for tracking marine mammals. Finally, in the realm of ‘acoustical oceanography’ and ‘ocean acoustic tomography,’ sound is used for measuring physical parameters of the ocean environment and for monitoring oceanic processes [1-6].

  16. Quasithermodynamic Contributions to the Fluctuations of a Protein Nanopore

    PubMed Central

    2015-01-01

    Proteins undergo thermally activated conformational fluctuations among two or more substates, but a quantitative inquiry on their kinetics is persistently challenged by numerous factors, including the complexity and dynamics of various interactions, along with the inability to detect functional substates within a resolvable time scale. Here, we analyzed in detail the current fluctuations of a monomeric β-barrel protein nanopore of known high-resolution X-ray crystal structure. We demonstrated that targeted perturbations of the protein nanopore system, in the form of loop-deletion mutagenesis, accompanying alterations of electrostatic interactions between long extracellular loops, produced modest changes of the differential activation free energies calculated at 25 °C, ΔΔG⧧, in the range near the thermal energy but substantial and correlated modifications of the differential activation enthalpies, ΔΔH⧧, and entropies, ΔΔS⧧. This finding indicates that the local conformational reorganizations of the packing and flexibility of the fluctuating loops lining the central constriction of this protein nanopore were supplemented by changes in the single-channel kinetics. These changes were reflected in the enthalpy–entropy reconversions of the interactions between the loop partners with a compensating temperature, TC, of ∼300 K, and an activation free energy constant of ∼41 kJ/mol. We also determined that temperature has a much greater effect on the energetics of the equilibrium gating fluctuations of a protein nanopore than other environmental parameters, such as the ionic strength of the aqueous phase as well as the applied transmembrane potential, likely due to ample changes in the solvation activation enthalpies. There is no fundamental limitation for applying this approach to other complex, multistate membrane protein systems. Therefore, this methodology has major implications in the area of membrane protein design and dynamics, primarily by revealing a better quantitative assessment on the equilibrium transitions among multiple well-defined and functionally distinct substates of protein channels and pores. PMID:25479108

  17. High-resolution resistivity imaging of marine gas hydrate structures by combined inversion of CSEM towed and ocean-bottom receiver data

    NASA Astrophysics Data System (ADS)

    Attias, Eric; Weitemeyer, Karen; Hölz, Sebastian; Naif, Samer; Minshull, Tim A.; Best, Angus I.; Haroon, Amir; Jegen-Kulcsar, Marion; Berndt, Christian

    2018-06-01

    We present high-resolution resistivity imaging of gas hydrate pipe-like structures, as derived from marine controlled-source electromagnetic (CSEM) inversions that combine towed and ocean-bottom electric field receiver data, acquired from the Nyegga region, offshore Norway. Two-dimensional CSEM inversions applied to the towed receiver data detected four new prominent vertical resistive features that are likely gas hydrate structures, located in proximity to a major gas hydrate pipe-like structure, known as the CNE03 pockmark. The resistivity model resulting from the CSEM data inversion resolved the CNE03 hydrate structure in high resolution, as inferred by comparison to seismically constrained inversions. Our results indicate that shallow gas hydrate vertical features can be delineated effectively by inverting both ocean-bottom and towed receiver CSEM data simultaneously. The approach applied here can be utilised to map and monitor seafloor mineralisation, freshwater reservoirs, CO2 sequestration sites and near-surface geothermal systems.

  18. Can bottom-up processes of attention be a source of 'interference' in situations where top-down control of attention is crucial?

    PubMed

    Nikolla, Dritan; Edgar, Graham; Catherwood, Dianne; Matthews, Tristan

    2018-02-01

    In this study, we investigate whether emotionally engaged bottom-up processes of attention can be a source of 'interference' in situations where top-down control of attention is necessary. Participants were asked to monitor and report on a video of a war scenario showing a developing battle in two conditions: emotionally positive and emotionally negative. Half of the participants (n = 15) were exposed to task-irrelevant pictures of positive emotional valence embedded within the scenario; the other half were exposed to task-irrelevant pictures of negative emotional valence. Sensitivity and Bias scores were calculated using signal detection theory. Overall, task accuracy scores were dependent upon the valence; negative pictures had an adverse effect on performance, whereas positive pictures improved performance. We concluded that negative emotional pictures interfered with top-down control of attention by attracting competing bottom-up processes of attention. We found the opposite effect for positive emotional stimuli. © 2017 The British Psychological Society.

  19. Acoustic water bottom investigation with a remotely operated watercraft survey system

    NASA Astrophysics Data System (ADS)

    Yamasaki, Shintaro; Tabusa, Tomonori; Iwasaki, Shunsuke; Hiramatsu, Masahiro

    2017-12-01

    This paper describes a remotely operated investigation system developed by combining a modern leisure-use fish finder and an unmanned watercraft to survey water bottom topography and other data related to bottom materials. Current leisure-use fish finders have strong depth sounding capabilities and can provide precise sonar images and bathymetric information. Because these sonar instruments are lightweight and small, they can be used on unmanned small watercraft. With the developed system, an operator can direct the heading of an unmanned watercraft and monitor a PC display showing real-time positioning information through the use of onboard equipment and long-distance communication devices. Here, we explain how the system was developed and demonstrate the use of the system in an area of submerged woods in a lake. The system is low cost, easy to use, and mobile. It should be useful in surveying areas that have heretofore been hard to investigate, including remote, small, and shallow lakes, for example, volcanic and glacial lakes.

  20. A bottom-up partnership of Andean institutions to improve hydrological interventions using a participatory network of research basins

    NASA Astrophysics Data System (ADS)

    Buytaert, W.; Ochoa-Tocachi, B. F.; De Bièvre, B.

    2017-12-01

    Many watershed interventions in remote data-scarce areas respond to information gaps by extrapolating conventional approaches based on very limited local evidence. However, most interventions, including conservation strategies and adaptation measures, have not been evaluated properly for their hydrological benefits. This is particularly the case for the Andean region, where the complex climatic and hydrological characteristics combined with a very dynamic anthropogenic disturbance, require better monitoring. Here, we present the experience of a partnership of academic and non-governmental institutions who pioneered participatory hydrological monitoring in the Andes. Established in 2009, the Regional Initiative for Hydrological Monitoring of Andean Ecosystems (iMHEA), is a bottom-up initiative that complements the national monitoring networks and more conventional scientific observatories. Using a design based on a trading-space-for-time approach, over 30 paired catchments with a variety of watershed interventions are currently being monitored by 18 local stakeholders in 15 sites in the tropical Andes. Pooling these data into a hydrological impact model allowed the consortium to make more robust predictions about the effectiveness of catchment interventions to improve water resources management and to reduce risks. The collaborative nature of iMHEA has several strengths. We identify as most important of those the ability to: (i) standardize monitoring practices; (ii) ensure quality and technical support; (iii) share responsibility of monitoring activities; (iv) obtain project co-funding and complementarity; and, (v) promote decision maker-scientist engagement. As a result, this network has started to deliver useful information to multi-scale and multi-stakeholder decision making arenas. For example, in the context of growing investment in hydrological ecosystem services in Peru, the sites provide a new generation of hydrological information that allows for evidence-based, cost-benefit comparisons. However, some challenges still remain in the scientific, technological and social domains, opening wide perspectives for future collaborative work.

Top