Sample records for bovine elisa kits

  1. Commercial Milk Enzyme-Linked Immunosorbent Assay (ELISA) Kit Reactivities to Purified Milk Proteins and Milk-Derived Ingredients.

    PubMed

    Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L

    2016-07-01

    Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®

  2. [Development of ELISA-kit of quantitative analysis for Zearalenone].

    PubMed

    Wang, Yu-ping; Ji, Rong; Jiang, Tao; Kang, Wei-jun

    2006-03-01

    To develope a rapid, sensitive, quantitative ELISA-kit for Zearalenone and determine zearalenone in cereals. On the base of monoclonal antibodies against ZEN, apply indirect ELISA to study the performance parameter of the kit. The limited concentration of detection of the ELISA-kit was 1ng/ml, linear range was 1-200 ng/ml, the linear equation was Y = 0.99 - 0.40 x (R2 = 0.99). The inhibition concentration of 50% against ZEN was 16.3 ng/ml. The average recovery rate of spiked corn and wheat was 96.5% and 95.5%, respectively, the coefficient of variant was 13.2% and 10.9%, respectively. The kit can be stored at 4 degrees C over 6 months. The cross reaction rate with the other mycotoxins was less than 1%, and coefficient of variant within-laboratory and between-laboratory was less than 15% and less than 20%, respectively. Detecting the VICAM sample with ELISA method and HPLC method, the results were within the range of the sample, and there was no statistic difference between the two methods. This ELISA-kit was quick, sensitive, stable and specific and can be used to determine ZEN in cereals.

  3. [Effect evaluation of three ELISA kits in detection of fasciolasis].

    PubMed

    Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu

    2013-04-01

    To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.

  4. Sero-prevalence of bovine Johne's disease in buffaloes and cattle population of North India using indigenous ELISA kit based on native Mycobacterium avium subspecies paratuberculosis 'Bison type' genotype of goat origin.

    PubMed

    Singh, S V; Singh, A V; Singh, R; Sharma, S; Shukla, N; Misra, S; Singh, P K; Sohal, J S; Kumar, H; Patil, P K; Misra, P; Sandhu, K S

    2008-09-01

    Present pilot study is the first attempt in the country to estimate sero-prevalence of Bovine Johne's disease (BJD) by screening cattle and buffaloes representing large population belonging to farmer's and farm herds in the home tracts (Uttar Pradesh (UP) and Punjab) of Hariana cattle and Murrah buffaloes in North India. Indigenous and in-house plate ELISA kit (using protoplasmic antigen from native Mycobacterium avium subsp. paratuberculosis 'Bison type' strain of goat origin), originally developed for goats and sheep was standardized in bovines and used for screening. For this study, 33 villages of south and west UP were randomly selected and surveyed from 2001 to 2003. There were 7943 farmer's families having 38,251 livestock, including cattle, buffaloes, goats and sheep (per family 4.8% livestock). Numerically, buffaloes and cattle were 54.7% and 22.1%, respectively. Serum samples were collected from 726 animals (4.2% of 16, 981 livestock with 4375 farmer's families) located in 33 randomly surveyed villages. Serum samples (699), submitted to Epidemiology Department of Veterinary College (Punjab Agricultural University, Ludhiana), in the year 2004 by farmer's and organized farm herds (Buffaloes, 372, Cattle, 327), were screened by this ELISA kit. Soluble protoplasmic antigen was prepared from Map (S 5) 'Bison type' strain isolated from a terminally sick goat with Johne's disease. Of the total 1425 bovine (Buffaloes and cattle) serum samples screened using indigenous ELISA kit, sero-prevalence of Johne's disease was 29.0% (28.6% in buffalo and 29.8% in cattle) in Northern India. State-wise sero-prevalence was 31.9% and 23.3% in UP and Punjab, respectively. In UP, of the 601 randomly sampled buffaloes, sero-prevalence was 40.3% (16.6% in young and 40.9% adults) and 25.5% (10.5% in young and 26.3% adults) in south and west UP, respectively. Of the 125 cattle screened, sero-prevalence was 42.6% (nil in young and 44.4% adults) and 30.0% (nil in young and 30.6% adults

  5. Evaluation of commercial ELISA kits for the detection of antibodies against bluetongue virus.

    PubMed

    Niedbalski, W

    2011-01-01

    The aim of this study was to estimate the diagnostic value of different commercially available ELISA kits for the detection of bluetongue virus (BTV) antibodies in infected and vaccinated animals. The relative specificity of ELISA kits was evaluated using a panel of sera originating from healthy cattle, never vaccinated nor exposed to BTV. All ELISA kits applied had a high relative specificity (99.3 - 100%). The relative sensitivity of ELISA kits assessed using a panel of sera collected from BTV infected cattle was also high and similar for all the kits (97.3 - 100%). However, the relative sensitivity evaluated on the basis of testing vaccinated animals was different: the highest sensitivity was found for Ingenasa, PrioCHECK and ID VET ELISAs (96.5 - 98.3%). Slightly lower sensitivity was calculated for Pourquier and LSI kits (82.8% and 85.4%, respectively) and much lower sensitivity was found for VMRD ELISA kit (69.5%). The repeatability of BTV ELISA kits was expressed as a coefficient of variation (CV) of results of sera tested 5 times in the same day and in different days by the period of 2 months, by the same person, in the same conditions, and by using the same equipment. The CVs of sera tested in all ELISA kits ranged from 6.1 to 9.8% and were below 10% threshold adopted as a maximum for the acceptable repeatability of the method. In conclusion, it can be stated that the applied ELISA kits can be a valuable diagnostic tool for the serological monitoring studies in the BTV contaminated premises. All the methods are very specific and sensitive when testing BTV infected animals. Nevertheless, the Ingenasa and PrioCHECK can be the most useful in sero-surveillance of livestock following vaccination.

  6. Advantage of using a home-made ELISA kit for detection of Helicobacter pylori infection over commercially imported kits.

    PubMed

    Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A

    2008-01-01

    To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.

  7. Validation of an improved Anaplasma antibody competitive ELISA for detection of Anaplasma ovis antibody in domestic sheep.

    PubMed

    Mason, Kathleen L; Gonzalez, Michael V; Chung, Chungwon; Mousel, Michelle R; White, Stephen N; Taylor, Joshua B; Scoles, Glen A

    2017-09-01

    An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identified using nested PCR (nPCR) as the gold standard. Negative bovine control sera supplied with the kit were used to calculate % inhibition (%I), designated bovine control ELISA (BcELISA), and this was compared to %I calculated from negative ovine sera derived from hand-raised, pathogen-free sheep, designated ovine control ELISA (OcELISA). The receiver operating characteristics area under the curve was 1.0 with a p value <0.001 regardless of the source of the control sera. The cutoff values for negative BcELISA and OcELISA were <30%I and <27%I, respectively. Our work confirmed that this Anaplasma antibody cELISA kit version 2 can be used with the serum controls supplied in the kit to test for A. ovis antibody in domestic sheep. Furthermore, this work confirmed the historically high infection prevalence (>93%) at the U.S. Sheep Experiment Station (Dubois, Idaho), in spite of efforts to reduce the possibility for iatrogenic transmission there, suggesting high levels of tick-borne transmission.

  8. Therapeutic drug monitoring of infliximab: performance evaluation of three commercial ELISA kits.

    PubMed

    Schmitz, Ellen M H; van de Kerkhof, Daan; Hamann, Dörte; van Dongen, Joost L J; Kuijper, Philip H M; Brunsveld, Luc; Scharnhorst, Volkher; Broeren, Maarten A C

    2016-07-01

    Therapeutic drug monitoring (TDM) of infliximab (IFX, Remicade®) can aid to optimize therapy efficacy. Many assays are available for this purpose. However, a reference standard is lacking. Therefore, we evaluated the analytical performance, agreement and clinically relevant differences of three commercially available IFX ELISA kits on an automated processing system. The kits of Theradiag (Lisa Tracker Infliximab), Progenika (Promonitor IFX) and apDia (Infliximab ELISA) were implemented on an automated processing system. Imprecision was determined by triplicate measurements of patient samples on five days. Agreement was evaluated by analysis of 30 patient samples and four spiked samples by the selected ELISA kits and the in-house IFX ELISA of Sanquin Diagnostics (Amsterdam, The Netherlands). Therapeutic consequences were evaluated by dividing patients into four treatment groups using cut-off levels of 1, 3 and 7 μg/mL and determining assay concordance. Within-run and between-run imprecision were acceptable (≤12% and ≤17%, respectively) within the quantification range of the selected ELISA kits. The apDia assay had the best precision and agreement to target values. Statistically significant differences were found between all assays except between Sanquin Diagnostics and the Lisa Tracker assay. The Promonitor assay measured the lowest IFX concentrations, the apDia assay the highest. When patients were classified in four treatment categories, 70% concordance was achieved. Although all assays are suitable for TDM, significant differences were observed in both imprecision and agreement. Therapeutic consequences were acceptable when patients were divided in treatment categories, but this could be improved by assay standardization.

  9. A New ELISA Using the ANANAS Technology Showing High Sensitivity to diagnose the Bovine Rhinotracheitis from Individual Sera to Pooled Milk.

    PubMed

    Casarin, Elisabetta; Lucchese, Laura; Grazioli, Santina; Facchin, Sonia; Realdon, Nicola; Brocchi, Emiliana; Morpurgo, Margherita; Nardelli, Stefano

    2016-01-01

    Diagnostic tests for veterinary surveillance programs should be efficient, easy to use and, possibly, economical. In this context, classic Enzyme linked ImmunoSorbent Assay (ELISA) remains the most common analytical platform employed for serological analyses. The analysis of pooled samples instead of individual ones is a common procedure that permits to certify, with one single test, entire herds as "disease-free". However, diagnostic tests for pooled samples need to be particularly sensitive, especially when the levels of disease markers are low, as in the case of anti-BoHV1 antibodies in milk as markers of Infectious Bovine Rhinotracheitis (IBR) disease. The avidin-nucleic-acid-nanoassembly (ANANAS) is a novel kind of signal amplification platform for immunodiagnostics based on colloidal poly-avidin nanoparticles that, using model analytes, was shown to strongly increase ELISA test performance as compared to monomeric avidin. Here, for the first time, we applied the ANANAS reagent integration in a real diagnostic context. The monoclonal 1G10 anti-bovine IgG1 antibody was biotinylated and integrated with the ANANAS reagents for indirect IBR diagnosis from pooled milk mimicking tank samples from herds with IBR prevalence between 1 to 8%. The sensitivity and specificity of the ANANAS integrated method was compared to that of a classic test based on the same 1G10 antibody directly linked to horseradish peroxidase, and a commercial IDEXX kit recently introduced in the market. ANANAS integration increased by 5-fold the sensitivity of the 1G10 mAb-based conventional ELISA without loosing specificity. When compared to the commercial kit, the 1G10-ANANAS integrated method was capable to detect the presence of anti-BHV1 antibodies from bulk milk of gE antibody positive animals with 2-fold higher sensitivity and similar specificity. The results demonstrate the potentials of this new amplification technology, which permits improving current classic ELISA sensitivity limits

  10. Development of an Indirect ELISA for Serological Diagnosis of Bovine herpesvirus 5

    PubMed Central

    Campos, Fabrício S.; da Rosa, Matheus C.; Finger, Paula F.; de Oliveira, Patricia D.; Conceição, Fabricio R.; Fischer, Geferson; Roehe, Paulo M.; Leite, Fábio P. L.

    2016-01-01

    Bovine herpesviruses 1 and 5 (BoHV-1 and BoHV-5) are economically important pathogens, associated with a variety of clinical syndromes, including respiratory and genital disease, reproductive failure and meningoencephalitis. The standard serological assay to diagnose BoHV-1 and BoHV-5 infections is the virus neutralization test (VNT), a time consuming procedure that requires manipulation of infectious virus. In the present study a highly sensitive and specific single dilution indirect ELISA was developed using recombinant glycoprotein D from BoHV-5 as antigen (rgD5ELISA). Bovine serum samples (n = 450) were screened by VNT against BoHV-5a and by rgD5ELISA. Compared with the VNT, the rgD5ELISA demonstrated accuracy of 99.8%, with 100% sensitivity, 96.7% specificity and coefficient of agreement between the tests of 0.954. The rgD5ELISA described here shows excellent agreement with the VNT and is shown to be a simple, convenient, specific and highly sensitive virus-free assay for detection of serum antibodies to BoHV-5. PMID:26866923

  11. Development of sandwich ELISA for testing bovine β-lactoglobulin allergenic residues by specific polyclonal antibody against human IgE binding epitopes.

    PubMed

    He, Shengfa; Li, Xin; Gao, Jinyan; Tong, Ping; Chen, Hongbing

    2017-07-15

    Bovine β-lactoglobulin (BLG) is the main allergen in cows' milk, and the most commonly used method for detecting BLG is enzyme-linked immunosorbent assay (ELISA). However, antibodies used in commercial ELISA kits do not recognize specifically BLG IgE epitopes. Here, an antibody specific to IgE linear epitopes for BLG was used to develop a sandwich ELISA using a rabbit anti-BLG polyclonal antibody. The linear range for BLG detection was 31.25-8000ng/mL and limit of detection was 1.96ng/mL. BLG content in dairy samples was determined, and there was a good agreement between this immunoassay and reversed-phase high-performance liquid chromatography with high recovery. Additionally, BLG content in food samples had an average recovery of 104.25%. Allergenic residues were also detected in hydrolyzed infant formulas. The method developed could be a practical approach to determine BLG and its allergenic residues in food with a high degree of sensitivity, reliability and recovery. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Short communication: ELISA system for screening of bovine mastitis caused by Prototheca zopfii.

    PubMed

    Kano, Rui; Sato, Ayano; Sobukawa, Hideto; Sato, Yuko; Ito, Takaaki; Suzuki, Kazuyuki; Hasegawa, Atsuhiko; Kamata, Hiroshi

    2016-08-01

    Prototheca zopfii is an achlorophyllic alga that causes bovine mastitis, resulting in a reduction in milk production and the secretion of thin, watery milk with white flakes. This study evaluated the use of an ELISA system for distinguishing cows with mastitis due to P. zopfii genotype 2 from healthy cows and cows with chronic candidal mastitis. We also investigated the transitional changes of specific antibody titers in healthy cows injected with inactivated P. zopfii genotype 2 cells. The ELISA system exhibited the highest sensitivity (94%) and specificity (100%) for chronic protothecal mastitis when the positive cutoff value was set at 43.4 ELISA units. Anti-protothecal IgG titers were positive in all cows after they were inoculated with inactivated P. zopfii genotype 2 cells. These results indicated that ELISA detection of anti-protothecal IgG in serum provided specificity and sensitivity sufficient for diagnosing protothecal mastitis. Thus, an ELISA system incorporating this specific antiserum is expected to be valuable for definitive field-based diagnosis of bovine mastitis due to P. zopfii genotype 2. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  13. Analysis of fenbendazole residues in bovine milk by ELISA.

    PubMed

    Brandon, David L; Bates, Anne H; Binder, Ronald G; Montague, William C; Whitehand, Linda C; Barker, Steven A

    2002-10-09

    Fenbendazole residues in bovine milk were analyzed by ELISAs using two monoclonal antibodies. One monoclonal antibody (MAb 587) bound the major benzimidazole anthelmintic drugs, including fenbendazole, oxfendazole, and fenbendazole sulfone. The other (MAb 591) was more specific for fenbendazole, with 13% cross-reactivity with the sulfone and no significant binding to the sulfoxide metabolite. The limit of detection of the ELISA method in the milk matrix was 7 ppb for MAb 587 and 3 ppb for MAb 591. Fenbendazole was administered in feed, drench, and paste form to three groups of dairy cattle. Milk was collected immediately before dosing and then every 12 h for 5 days. The ELISA indicated that residue levels varied widely among individual cows in each group. Fenbendazole levels peaked at approximately 12-24 h and declined rapidly thereafter. Metabolites were detected at much higher levels than the parent compound, peaked at approximately 24-36 h, and declined gradually. Residue levels were undetectable by 72 h. The ELISA data correlated well with the total residues determined by chromatographic analysis, but the use of the two separate ELISAs did not afford an advantage over ELISA with the single, broadly reactive MAb 587. The ELISA method could be used to flag high-residue samples in on-site monitoring of fenbendazole in milk and is a potential tool for studying drug pharmacokinetics.

  14. Comparison of three commercial IgG and IgM ELISA kits for the detection of tick-borne encephalitis virus antibodies.

    PubMed

    Ackermann-Gäumann, Rahel; Tritten, Marie-Lise; Hassan, Mona; Lienhard, Reto

    2018-05-01

    Tick-borne encephalitis (TBE) is endemic in many parts of Europe and Asia. The diagnosis of this disease is essentially based on the demonstration of specific antibodies. For reasons of simplicity, automatization and quick availability of test results, enzyme-linked immunosorbent assays (ELISAs) are the method of choice for serological diagnosis of TBE. Here, we evaluated three commercially available anti-TBEV IgG and IgM ELISAs using 251 serum samples: the SERION ELISA classic FSME Virus/TBE Virus IgG and IgM kit (Virion\\Serion), the RIDASCREEN ® FSME/TBE IgG and IgM kit (R-Biopharm), and the anti-FSME/TBE virus ELISA "Vienna" IgG/anti-FSME/TBE virus ELISA IgM kit (Euroimmun). In total, discrepant test results for IgG and/or IgM were observed for 37/251 (14.7 %) of tested samples; differences were statistically significant. Reference values defined by serum neutralization test (SNT, n = 25) or results provided by EQA organizers (n = 2) were established for a subset of samples. In relation to these values, false-positive results were observed mainly for Euroimmun Vienna IgG and RIDASCREEN IgG, whereas false-negative results were primarily observed for Virion\\Serion IgG and RIDASCREEN IgM kits. In routine diagnostics, specificity problems are of major relevance and may be addressed by analyzing the respective samples using SNT. Copyright © 2018 Elsevier GmbH. All rights reserved.

  15. Serological diagnosis of bovine neosporosis: a comparative study of commercially available ELISA tests.

    PubMed

    Alvarez-García, Gema; García-Culebras, Alicia; Gutiérrez-Expósito, Daniel; Navarro-Lozano, Vanesa; Pastor-Fernández, Iván; Ortega-Mora, Luis Miguel

    2013-11-15

    Bovine neosporosis control programs are currently based on herd management and serodiagnosis because effective treatments and vaccines are unavailable. Although a wide variety of serological tools have been developed, enzyme-linked immunosorbent assays (ELISAs) are the most commonly commercialized tests. Partial comparative studies have been performed in the past, and the panel of available ELISAs has notably changed in the last few years. Therefore, diagnostic laboratories are requesting updated information about the performance of these tests. Accordingly, the aim of this study was to compare all of the commercially available ELISAs (n=10) by evaluating their performance and to re-standardize them based on TG-ROC analyses when necessary. For this purpose, a well-characterized serum panel from experimentally and naturally infected bovines and non-infected bovines (n=458) was used. Two different definitions of gold standard were considered: (i) the result of the majority of tests and (ii) pre-test information based on epidemiological, clinical and serological data. Most of the tests displayed high sensitivity (Se) and specificity (Sp) values when both gold standard criteria were considered. Furthermore, all the tests showed near perfect agreement, with the exception of the pair-wise comparisons that included the VMRD and SVANOVIR. The best-adjusted ELISAs were the HIPRA-CIVTEST, IDVET, BIOVET and IDEXX Rum (Se and Sp>95%). After the TG-ROC analyses, higher Se and Sp values were obtained for the BIO-X, LSI Bov, LSI Rum and IDEXX Bov, though the increases were more significant for the SVANOVIR and VMRD. The Kappa values also increased with the new adjusted cut-offs. This is the first study that offers updated performance evaluations of commercially available ELISAs. Such analyses are essential for diagnostic laboratories and are valuable to the companies that develop and distribute these tests. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Evaluation of a dot ELISA kit for measuring immunoglobulin M antibodies to canine parvovirus and distemper virus.

    PubMed

    Waner, T; Mazar, S; Nachmias, E; Keren-Kornblatt, E; Harrus, S

    2003-05-10

    A dot ELISA for the detection of immunoglobulin M (IgM) antibodies to canine distemper virus (CDC) and canine parvovirus (CPV) was assessed. The titres of IgM antibodies to CDV and CPV in 100 dogs were measured by the Immunocomb ELISA kit and compared with the results derived from the immunofluorescence assay (IFA). There was a strong correlation between the results of the dot ELISA technique and the IFA (P < 0.001). The dot ELISA kit was also used to assess the changes in the levels of immunoglobulin G (IgG) and IgM antibodies to CPV and CDV in 10 puppies vaccinated with a polyvalent vaccine. High levels of IgM antibodies to CPV were first detected seven days after they were vaccinated, and after nine days all the pups had high titres of IgG antibodies to CPV. High levels of IgM antibodies to CDV were detected after nine days and the highest average titres were recorded after 12 days. IgG antibodies to CDV were present from nine days after vaccination.

  17. Development of a H2 O2 -sensitive quantum dots-based fluorescent sandwich ELISA for sensitive detection of bovine β-lactoglobulin by monoclonal antibody.

    PubMed

    He, Shengfa; Li, Xin; Gao, Jinyan; Tong, Ping; Chen, Hongbing

    2018-01-01

    Bovine β-lactoglobulin (BLG) is the major allergen in cows' milk, and the specific epitope plays a key role in food allergy. Developing a method specifically bind to the IgE epitope is necessary for testing BLG and its allergenic residues. The monoclonal antibody (1G9) specific to the IgE linear epitope for BLG was identified as high affinity and specificity. Based on 1G9, a sensitive fluorescent sandwich enzyme-linked immunosorbent assay (sELISA) was successfully developed using catalase-mediated fluorescence quenching of thiolated CdTe quantum dots in the presence of hydrogen peroxide as fluorescent signal output. The fluorescent sELISA showed high sensitivity and specificity, the limit of detection was 0.49 ng mL -1 , which was 16-fold lower than horseradish peroxidase (HRP)-based sELISA. The linear range for BLG detection were 125-4000 ng mL -1 (r = 0.9939) and 0.48-62.5 ng mL -1 (r = 0.9919). The recoveries and coefficients of variation were 94.25-109.83% and 4.38-20.29%, respectively. Allergenic residues were also detected in hydrolysed infant formulas. The results of fluorescent sELISA showed good performance as HRP-based sELISA and commercial sELISA kit. This proposed fluorescent sELISA could be employed to detect BLG and its allergenic residues in food with highly sensitivity, reliability, and recovery. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  18. Evaluation of six serological ELISA kits available in Italy as screening tests for equine infectious anaemia surveillance.

    PubMed

    Nardini, Roberto; Autorino, Gian Luca; Issel, Charles J; Cook, R Frank; Ricci, Ida; Frontoso, Raffaele; Rosone, Francesca; Scicluna, Maria Teresa

    2017-04-14

    ELISAs are known to have a higher diagnostic sensitivity than the agar gel immunodiffusion (AGID) when employed for serological diagnosis of equine infectious anaemia (EIA). For this purpose, an "in-house" and five commercial ELISAs available in Italy were assessed by the National Reference Centre for EIA for their analytic specificity (Sp); precocity, defined as capability of detecting first antibodies produced during a new infection; precision based on repeatability and reproducibility, estimated from the coefficient of variation (CV); accuracy, estimated from multiple K and relative Sp and sensitivity (Se). Two serum panels, positive for non-equine retroviruses and the most frequent equine viruses, were employed to measure analytic Sp. ELISA precocity was also compared to that of one "in-house" and three commercial AGID kits, employing a panel of sera, collected weekly from horses infected with modified EIA viruses. Precision and accuracy were defined using results of a panel containing positive and negative sera examined in an inter-laboratory trial with the participation of the ten Official Laboratories. Furthermore, a questionnaire was used to assess the appropriateness of each kit for routine use. Analytic Sp was 100%, while the 75th percentile of CVs for positive sera varied from 0.4% to 12.73% for repeatability and from 1.6% to 44.87% for reproducibility. Although CV of the negative serum was constantly high, its outcome was unaltered. Relative Se ranged from 98.2% to 100%, relative Sp was constantly 100% and multiple K ranged from 0.95 to 1. Precocity differed among the assays: three kits detected 4.8% and 42.9% positive samples on 21 days post infection (dpi), all assays detected positive samples on 28 dpi, between 47.6% and 95.2%. Precocity of ELISAs was superior to that of the AGIDs except for two assays. In view of the feedback obtained from the questionnaires, all kits were considered appropriate for routine use. All ELISAs having high Se and

  19. Development and validation of an ELISA kit for the detection of ricin toxins from biological specimens and environmental samples.

    PubMed

    Chen, Hsiao Ying; Tran, Hung; Foo, Ling Yann; Sew, Tracey Wenhui; Loke, Weng Keong

    2014-08-01

    Ricin is a toxin that can be easily extracted from seeds of Ricinus communis plants. Ricin is considered to be a major bio-threat as it can be freely and easily acquired in large quantities. A deliberate release of such toxin in civilian populations would very likely overwhelm existing public health systems, resulting in public fear and social unrest. There is currently no commercially available or FDA-approved prophylaxis such as vaccines, or therapeutic antitoxins or antidotes, available for ricin intoxication. Patient treatment is typically supportive care based on symptoms, often designed to reinforce the body's natural response. This paper describes the development and validation of a robust ELISA test kit, which can be used to screen for ricin in biological specimens such as whole blood and faeces. Faecal specimens are shown in this study to have better diagnostic sensitivity and a wider diagnostic window compared to whole blood. From these results, it is concluded that faeces is the most suitable clinical specimen for diagnosis of ricin poisoning via the oral route. The ELISA test kit can also detect ricin in environmental samples. An advantage of this ELISA kit over other commercial off-the-shelf (COTS) detection kits currently on the market that are developed to screen environmental samples only is its ability to diagnose ricin poisoning from clinical specimens as well as detect ricin from environmental samples.

  20. Evaluation and comparison of native and recombinant LipL21 protein-based ELISAs for diagnosis of bovine leptospirosis.

    PubMed

    Joseph, Siju; Thomas, Naicy; Thangapandian, E; Singh, Vijendra P; Verma, Rishendra; Srivastava, S K

    2012-03-01

    A 21-kDa leptospiral lipoprotein (LipL21) was evaluated for its diagnostic potential to detect bovine leptospirosis by ELISA. Both native LipL21 (nLipL21) and recombinant LipL21 (rLipL21) proteins were tested and compared regarding diagnostic efficiency, and no statistically significant difference was observed. The sensitivity of rLipL21 ELISA for 62 microscopic agglutination test (MAT) positive sera was 100% and the specificity with 378 MAT negative sera was 97.09%. Thus, rLipL21 protein-based ELISA could be used as an alternative to MAT for the diagnosis of bovine leptospirosis.

  1. Validation of an Anaplasma marginale cELISA for use in the diagnosis of A. ovis infections in domestic sheep and Anaplasma spp. in wild ungulates.

    PubMed

    Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P

    2008-07-27

    A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.

  2. Assessment of the diagnostic sensitivity and specificity of an indirect ELISA kit for the diagnosis of Brucella ovis infection in rams.

    PubMed

    Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno

    2012-07-09

    Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the

  3. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer

    USDA-ARS?s Scientific Manuscript database

    Background The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed...

  4. Development of an Indirect ELISA Based on a Recombinant Chimeric Protein for the Detection of Antibodies against Bovine Babesiosis

    PubMed Central

    Jaramillo Ortiz, José Manuel; Montenegro, Valeria Noely; de la Fournière, Sofía Ana María; Sarmiento, Néstor Fabián; Farber, Marisa Diana; Wilkowsky, Silvina Elizabeth

    2018-01-01

    The current method for Babesia spp. serodiagnosis based on a crude merozoite antigen is a complex and time-consuming procedure. An indirect enzyme-linked immunosorbent assay (iELISA) based on a recombinant multi-antigen of Babesia bovis (rMABbO) was developed for detection of antibodies in bovines suspected of infection with this parasite. The multi-antigen comprises gene fragments of three previously characterized B. bovis antigens: MSA-2c, RAP-1 and the Heat Shock protein 20 that are well-conserved among geographically distant strains. The cutoff value for the new rMABbo-iELISA was determined using 75 known—positive and 300 known—negative bovine sera previously tested for antibodies to B. bovis by the gold-standard ELISA which uses a merozoite lysate. A cutoff value of ≥35% was determined in these samples by receiver operator characteristic (ROC) curve analysis, showing a sensitivity of 95.9% and a specificity of 94.3%. The rMABbo-iELISA was further tested in a blind trial using an additional set of 263 field bovine sera from enzootic and tick-free regions of Argentina. Results showed a good agreement with the gold standard test with a Cohen’s kappa value of 0.76. Finally, the prevalence of bovine babesiosis in different tick enzootic regions of Argentina was analyzed where seropositivity values among 68–80% were obtained. A certain level of cross reaction was observed when samples from B. bigemina infected cattle were analyzed with the new test, which can be attributed to shared epitopes between 2 of the 3 antigens. This new rMABbo-iELISA could be considered a simpler alternative to detect anti Babesia spp. antibodies and appears to be well suited to perform epidemiological surveys at the herd level in regions where ticks are present. PMID:29360801

  5. Development of an Indirect ELISA Based on a Recombinant Chimeric Protein for the Detection of Antibodies against Bovine Babesiosis.

    PubMed

    Jaramillo Ortiz, José Manuel; Montenegro, Valeria Noely; de la Fournière, Sofía Ana María; Sarmiento, Néstor Fabián; Farber, Marisa Diana; Wilkowsky, Silvina Elizabeth

    2018-01-23

    The current method for Babesia spp. serodiagnosis based on a crude merozoite antigen is a complex and time-consuming procedure. An indirect enzyme-linked immunosorbent assay (iELISA) based on a recombinant multi-antigen of Babesia bovis (rMABbO) was developed for detection of antibodies in bovines suspected of infection with this parasite. The multi-antigen comprises gene fragments of three previously characterized B. bovis antigens: MSA-2c, RAP-1 and the Heat Shock protein 20 that are well-conserved among geographically distant strains. The cutoff value for the new rMABbo-iELISA was determined using 75 known-positive and 300 known-negative bovine sera previously tested for antibodies to B. bovis by the gold-standard ELISA which uses a merozoite lysate. A cutoff value of ≥35% was determined in these samples by receiver operator characteristic (ROC) curve analysis, showing a sensitivity of 95.9% and a specificity of 94.3%. The rMABbo-iELISA was further tested in a blind trial using an additional set of 263 field bovine sera from enzootic and tick-free regions of Argentina. Results showed a good agreement with the gold standard test with a Cohen's kappa value of 0.76. Finally, the prevalence of bovine babesiosis in different tick enzootic regions of Argentina was analyzed where seropositivity values among 68-80% were obtained. A certain level of cross reaction was observed when samples from B. bigemina infected cattle were analyzed with the new test, which can be attributed to shared epitopes between 2 of the 3 antigens. This new rMABbo-iELISA could be considered a simpler alternative to detect anti Babesia spp. antibodies and appears to be well suited to perform epidemiological surveys at the herd level in regions where ticks are present.

  6. Validation of Geno-Sen's Scrub Typhus Real Time Polymerase Chain Reaction Kit by its Comparison with a Serological ELISA Test.

    PubMed

    Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan

    2017-01-01

    In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015- September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.

  7. Clinical effectiveness and cost-effectiveness of use of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [LISA-TRACKER® enzyme-linked immunosorbent assay (ELISA) kits, TNF-α-Blocker ELISA kits and Promonitor® ELISA kits] versus standard care in patients with Crohn's disease: systematic reviews and economic modelling.

    PubMed

    Freeman, Karoline; Connock, Martin; Auguste, Peter; Taylor-Phillips, Sian; Mistry, Hema; Shyangdan, Deepson; Court, Rachel; Arasaradnam, Ramesh; Sutcliffe, Paul; Clarke, Aileen

    2016-11-01

    Systematic reviews and economic modelling of clinical effectiveness and cost-effectiveness of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [using LISA-TRACKER ® enzyme-linked immunosorbent assay (ELISA) kits (Theradiag, Marne La Vallee, France, or Alpha Laboratories, Heriot, UK), TNF-α-Blocker ELISA kits (Immundiagnostik AG, Bensheim, Germany) and Promonitor ® ELISA kits (Proteomika, Progenika Biopharma, Bizkaia, Spain)] versus standard care for Crohn's disease (CD). Multiple electronic databases were searched from inception to December 2014 in order to identify primary studies and meta-analyses. Patients with moderate to severe active CD treated with infliximab (IFX) (Remicade ® , Merck Sharp & Dohme Ltd, Kenilworth, NJ, USA) or adalimumab (ADA) (Humira ® , AbbVie Inc., North Chicago, IL, USA). Monitoring of serum anti-TNF-α (IFX or ADA) and/or of anti-drug antibody levels using test assays with a test-treatment algorithm. Standard care. Any patient-related outcome, test agreement and cost-effectiveness estimates. The quality assessments used recognised checklists (Quality Assessment of Diagnostic Accuracy Studies-2, Cochrane, Philips and Consolidated Health Economic Evaluation Reporting Standards). Evidence was synthesised using narrative review and meta-analysis. A Markov model was built in TreeAge Pro 2013 (TreeAge Software, Inc., Williamstown, MA, USA). The model had a 4-week cycle and a 10-year time horizon, adopted a NHS and Personal Social Services perspective and used a linked evidence approach. Costs were adjusted to 2013/14 prices and discounted at 3.5%. We included 68 out of 2434 and 4 out of 2466 studies for the clinical effectiveness and cost-effectiveness reviews, respectively. Twenty-three studies comparing test methods were identified. Evidence on test concordance was sparse and contradictory, offering scant data for a linked evidence approach. Three studies [two randomised controlled trials (RCTs) and one

  8. Evaluation of a recombinant LipL41 antigen of Leptospira interrogans serovar canicola in ELISA for serodiagnosis of bovine leptospirosis.

    PubMed

    Mariya, R; Chaudhary, Pallab; Kumar, A A; Thangapandian, E; Amutha, R; Srivastava, S K

    2006-11-01

    The efficacy of a recombinant leptospiral lipoprotein LipL41 as an antigen for conducting enzyme-linked immunosorbent assay (ELISA) for diagnosis of bovine leptospirosis was evaluated. Using known positive and known negative cattle sera the recombinant antigen was found to be highly reactive in the concentration of 100 ng/well. Using a total of 321 field cattle sera the sensitivity of ELISA as compared to microscopic agglutination test (MAT) was calculated to be 100% whereas the specificity was 85.3%. The seropositivity of leptospirosis among bovine population was found to be 21.18% having the predominance of serovars Sejroe and Pomona. It was concluded that rLipL41 protein could be a putative diagnostic candidate for serodiagnosis of bovine leptospirosis.

  9. Validation of Geno-Sen's Scrub Typhus Real Time Polymerase Chain Reaction Kit by its Comparison with a Serological ELISA Test

    PubMed Central

    Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan

    2017-01-01

    Background: In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR. PMID:28878522

  10. Validation of an indirect ELISA to detect antibodies against BoHV-1 in bovine and guinea-pig serum samples using ISO/IEC 17025 standards.

    PubMed

    Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando

    2010-10-01

    Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.

  11. Nested-PCR and a new ELISA-based NovaLisa test kit for malaria diagnosis in an endemic area of Thailand.

    PubMed

    Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara

    2014-08-01

    Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.

  12. Unreliability of three commercial Coxiella burnetii phase II IgM ELISA kits for the seroscreening of acute Q fever in human cases.

    PubMed

    Stephen, Selvaraj; Ambroise, Stanley; Pradeep, Jothimani; Gunasekaran, Dhandapany; Sangeetha, Balakrishnan; Sarangapani, Kengamuthu

    2017-09-01

    Seroprevalence of Q fever (QF) caused by Coxiella burnetii has been reported from different parts of India. Usually serological/molecular tests are employed for detection of infection. The present study was undertaken to verify the validity of three different QF phase II IgM ELISA kits for acute QF diagnosis by comparing with the gold standard indirect fluorescent antibody assay (IFA). Fifty eight serum samples collected from 42 patients (26 patients provided acute sample only and 16 both acute and convalescent samples) which were examined by all three commercial kits, were cross-checked with QF Phase II IgM IFA for confirmation. Eleven patients were positive for C. burnetii antibodies by IFA in acute and/or convalescent serum samples. Taking IFA as a reference, percentages of sensitivity, specificity, positive predictive value and negative predictive value for Virion-Serion/Vircell/NovaTec were 36.36, 61.29, 25.00, 73.08; 81.82, 35.48, 31.03, 84.62 and 100, 25.81, 32.35, 100 per cent, respectively. The three different ELISA kits exhibited poor agreement amongst them and unacceptable level of false positivity. IFA remains to be the only option for diagnosing acute QF. Discrepancy between the clinical findings and IFA/ELISA results needs confirmation by C. burnetii DNA detection in real-time polymerase chain reaction.

  13. Unreliability of three commercial Coxiella burnetii phase II IgM ELISA kits for the seroscreening of acute Q fever in human cases

    PubMed Central

    Stephen, Selvaraj; Ambroise, Stanley; Pradeep, Jothimani; Gunasekaran, Dhandapany; Sangeetha, Balakrishnan; Sarangapani, Kengamuthu

    2017-01-01

    Background & objectives: Seroprevalence of Q fever (QF) caused by Coxiella burnetii has been reported from different parts of India. Usually serological/molecular tests are employed for detection of infection. The present study was undertaken to verify the validity of three different QF phase II IgM ELISA kits for acute QF diagnosis by comparing with the gold standard indirect fluorescent antibody assay (IFA). Methods: Fifty eight serum samples collected from 42 patients (26 patients provided acute sample only and 16 both acute and convalescent samples) which were examined by all three commercial kits, were cross-checked with QF Phase II IgM IFA for confirmation. Results: Eleven patients were positive for C. burnetii antibodies by IFA in acute and/or convalescent serum samples. Taking IFA as a reference, percentages of sensitivity, specificity, positive predictive value and negative predictive value for Virion-Serion/Vircell/NovaTec were 36.36, 61.29, 25.00, 73.08; 81.82, 35.48, 31.03, 84.62 and 100, 25.81, 32.35, 100 per cent, respectively. Interpretation & conclusions: The three different ELISA kits exhibited poor agreement amongst them and unacceptable level of false positivity. IFA remains to be the only option for diagnosing acute QF. Discrepancy between the clinical findings and IFA/ELISA results needs confirmation by C. burnetii DNA detection in real-time polymerase chain reaction. PMID:29355147

  14. Design of Indigenous ELISA Using Tachyzoites from the RH Strain of Toxoplasma gondii and Comparison with Commercial Kits in Ahvaz, Southwest of Iran, 2015.

    PubMed

    Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman

    2016-10-01

    Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.

  15. Comparative study of three screening tests, two microbiological tube tests, and a multi-sulphonamide ELISA kit for the detection of antimicrobial and sulphonamide residues in eggs.

    PubMed

    Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E

    2009-04-01

    The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.

  16. Old and new diagnostic approaches for Q fever diagnosis: correlation among serological (CFT, ELISA) and molecular analyses.

    PubMed

    Natale, A; Bucci, G; Capello, K; Barberio, A; Tavella, A; Nardelli, S; Marangon, S; Ceglie, L

    2012-07-01

    The objective of this study was to evaluate the performance of the complement fixation test (CFT) with respect to ELISA for the serological diagnosis of Q fever and to assess the role of serology as a tool for the identification of the shedder status. During 2009-2010, sera from 9635 bovines and 3872 small ruminants (3057 goats and 815 sheep) were collected and analyzed with CFT and ELISA. In addition, 2256 bovine, 139 caprine and 72 ovine samples (individual and bulk tank milk samples, fetuses, vaginal swabs and placentae) were analyzed with a real-time PCR kit. The relative sensitivity (Se) and specificity (Sp) of CFT with respect to ELISA were Se 26.56% and Sp 99.71% for cattle and Se 9.96% and Sp 99.94% for small ruminants. To evaluate the correlation between serum-positive status and shedder status, the ELISA, CFT and real-time PCR results were compared. Due to the sampling method and the data storage system, the analysis of individual associations between the serological and molecular tests was possible only for some of the bovine samples. From a statistical point of view, no agreement was observed between the serological and molecular results obtained for fetus and vaginal swab samples. Slightly better agreement was observed between the serological and molecular results obtained for the individual milk samples and between the serological (at least one positive in the examined group) and molecular results for the bulk tank milk (BTM) samples. The CFT results exhibited a better correlation with the shedder status than did the ELISA results. Copyright © 2012 Elsevier Ltd. All rights reserved.

  17. Evaluation of a culture-based pathogen identification kit for bacterial causes of bovine mastitis.

    PubMed

    Viora, L; Graham, E M; Mellor, D J; Reynolds, K; Simoes, P B A; Geraghty, T E

    2014-07-26

    Accurate identification of mastitis-causing bacteria supports effective management and can be used to implement selective use of antimicrobials for treatment. The objectives of this study were to compare the results from a culture-based mastitis pathogen detection test kit ('VetoRapid', Vétoquinol) with standard laboratory culture and to evaluate the potential suitability of the test kit to inform a selective treatment programme. Overall 231 quarter milk samples from five UK dairy farms were collected. The sensitivity and specificity of the test kit for the identification of Escherichia coli, Staphylococcus aureus, coagulase-negative staphylococci, Streptococcus uberis and Enterococcus spp. ranged from 17 per cent to 84 per cent and 92 per cent to 98 per cent, respectively. In total, 23 of 68 clinical samples were assigned as meeting the requirement for antimicrobial treatment (Gram-positive organism cultured) according to standard culture results, with the test kit results having sensitivity and specificity of 91 per cent and 78 per cent, respectively. Several occurrences of misidentification are reported, including S. aureus being misidentified as coagulase-negative staphylococci and vice versa. The test kit provides rapid preliminary identification of five common causes of bovine mastitis under UK field conditions and is likely to be suitable for informing selective treatment of clinical mastitis caused by Gram-positive organisms. British Veterinary Association.

  18. Comparative evaluation of non-structural protein-antibody detecting ELISAs for foot-and-mouth disease sero-surveillance under intensive vaccination.

    PubMed

    Sharma, Gaurav Kumar; Mohapatra, Jajati Keshari; Mahajan, Sonalika; Matura, Rakesh; Subramaniam, Saravanan; Pattnaik, Bramhadev

    2014-10-01

    Foot-and-mouth disease is a highly infectious and contagious disease of livestock animals with transboundary and economical importance. Animals in the endemic settings are regularly vaccinated in addition to intensive surveillance for control of the disease. Under intensive vaccination, detection of infected animals among the vaccinated population is essential to monitor the infection and to track down the virus movement. Sero-surveillance and retrospective disease diagnosis is performed primarily by detecting antibodies against non-structural proteins (NSPs) of FMD virus which are usually absent in the inactivated vaccine formulations. The study was conducted with an objective to compare simultaneously performance of six NSP ELISAs in detecting infected animals in the areas covered under intensive vaccination, and to assess their fit-for-purpose attribute for sero-surveillance of FMD in India. A panel of bovine serum samples consisting of samples collected from infected with FMDV, vaccinated and naive animals were constituted. In addition, samples collected at random from areas having varied FMD situation and vaccination coverage were tested simultaneously by the six NSP ELISAs to compare their performances. The four indigenous assays showed varying degrees of correlation with the two commercial kits. The study validated that, in all the groups of samples, the indigenous assays were equally sensitive and specific as the two commercial kits. Among all the six assays, PrioCheck and in-house 3ABC I-ELISAs showed maximum sensitivity for detection of infected animals, whereas 3AB3 I-ELISA and 3ABC C-ELISA showed maximum specificity. The study concluded that the in-house available assays are equally capable as the commercially available kits for differentiation of infected animals under intensive vaccination and identifies the 3AB3 I-ELISA with optimum sensitivity and specificity for the purpose of sero-surveillance in India. Copyright © 2014 Elsevier B.V. All rights

  19. Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer.

    PubMed

    Wadhwa, Ashutosh; Johonson, Rachel E; Eda, Keiko; Waters, W Ray; Palmer, Mitchell V; Bannantine, John P; Eda, Shigetoshi

    2014-07-04

    The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed by using ethanol extract of Mycobacterium bovis (M. bovis). The assay, named (ethanol vortex ELISA [EVELISA]), was evaluated for detection of anti- M. bovis antibodies in the sera of cattle and white-tailed deer. By using the EVELISA, we tested sera obtained from two species of animals; cattle (n = 62 [uninfected, n = 40; naturally infected, n = 22]) and white-tailed deer (n = 41 [uninfected, n = 25; naturally infected, n = 7; experimentally infected, n = 9]). To detect species specific molecules, components in the ethanol extract were analyzed by thin layer chromatography and western blotting. Among the tested animals, 77.2% of infected cattle and 87.5% of infected deer tested positive for anti- M. bovis antibody. There were only minor false positive reactions (7.5% in cattle and 0% in deer) in uninfected animals. M. bovis -specific lipids and protein (MPB83) in the ethanol extract were detected by thin layer chromatography and western blotting, respectively. The results warrant further evaluation and validation of EVELISA for bovine TB diagnosis of traditional and alternative livestock as well as for free-ranging animal species.

  20. Validation of an improved anaplasma antibody cELISA kit for detection of anaplasma ovis antibody in domestic sheep at the U.S. Sheep Experiment Station in Dubois, ID

    USDA-ARS?s Scientific Manuscript database

    An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...

  1. Evaluation of a multiplex immunoassay for bovine respiratory syncytial virus and bovine coronavirus antibodies in bulk tank milk against two indirect ELISAs using latent class analysis.

    PubMed

    Toftaker, Ingrid; Toft, Nils; Stokstad, Maria; Sølverød, Liv; Harkiss, Gordon; Watt, Neil; O' Brien, Amanda; Nødtvedt, Ane

    2018-06-01

    Bovine respiratory syncytial virus (BRSV) and bovine coronavirus (BCV) are responsible for respiratory disease and diarrhea in cattle worldwide. The Norwegian control program against these infections is based on herd-level diagnosis using a new multiplex immunoassay. The objective of this study was to estimate sensitivity and specificity across different cut-off values for the MVD-Enferplex BCV/BRSV multiplex, by comparing them to a commercially available ELISA, the SVANOVIR ® BCV-Ab and SVANOVIR ® BRSV-Ab, respectively. We analyzed bulk tank milk samples from 360 herds in a low- and 360 herds in a high-prevalence area. As none of the tests were considered perfect, estimation of test characteristics was performed using Bayesian latent class models. At the manufacturers' recommended cut-off values, the median sensitivity for the BRSV multiplex and the BRSV ELISA was 94.4 [89.8-98.7 95% Posterior Credibility Interval (PCI)] and 99.8 [98.7-100 95% PCI], respectively. The median specificity for the BRSV multiplex was 90.6 [85.5-94.4 95% PCI], but only 57.4 [50.5-64.4 95% PCI] for the BRSV ELISA. However, increasing the cut-off of the BRSV ELISA increased specificity without compromising sensitivity. For the BCV multiplex we found that by using only one of the three antigens included in the test, the specificity increased, without concurrent loss in sensitivity. At the recommended cut-off this resulted in a sensitivity of 99.9 [99.3-100 95% PCI] and specificity of 93.7 [88.8-97.8 95% PCI] for the multiplex and a sensitivity of 99.5 [98.1-100 95% PCI] and a specificity of 99.6 [97.6-100 95% PCI] for the BCV ELISA. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Single-Tier Testing with the C6 Peptide ELISA Kit Compared with Two-Tier Testing for Lyme Disease

    PubMed Central

    Wormser, Gary P.; Schriefer, Martin; Aguero-Rosenfeld, Maria E.; Levin, Andrew; Steere, Allen C.; Nadelman, Robert B.; Nowakowski, John; Marques, Adriana; Johnson, Barbara J. B.; Dumler, J. Stephen

    2014-01-01

    Background The two-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time and labor; and subjectivity in the interpretation of immunoblots. Methods The diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with two-tier testing. Results The C6 ELISA was significantly more sensitive than two-tier testing with sensitivities of 66.5% (95% C.I.:61.7-71.1) and 35.2% (95%C.I.:30.6-40.1), respectively (p<0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to two-tier testing in sera from Lyme disease patients with early neurological manifestations (88.6% vs. 77.3%, p=0.13) or arthritis (98.3% vs. 95.6%, p= 0.38). Te specificities of C6 ELISA and two-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (p<0.05, 95% C.I. surrounding the 0.6 percentage point difference of 0.04 to 1.15). Conclusions Using a reference standard of two-tier testing, the C6 ELISA as a single step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with two-tier testing in routine clinical practice. PMID:23062467

  3. Determining bovine viral diarrhea and infectious bovine rhinotracheitis infections in dairy cattle using precolostral blood.

    PubMed

    Baillargeon, Paul; Arango-Sabogal, Juan C; Wellemans, Vincent; Fecteau, Gilles

    2017-04-01

    The objective of this study was to determine if precolostral blood samples are useful to detect apparent fetal infections with bovine viral diarrhea (BVD) and infectious bovine rhinotracheitis (IBR) viruses. A convenience sample of 317 sera from 50 Canadian herds was used in the study. Antibody level was measured using 2 commercial IBR and BVD ELISA kits. Precolostral status of sera was confirmed on 304 samples using serum gamma-glutamyl transferase activity. Postcolostral serum samples yielded a higher proportion of positive results to IBR (OR = 86; 95% CI: 17.8 to 415.7) and BVD (OR = 199.3; 95% CI: 41.7 to 952.3) than did precolostral samples. All positive precolostral serum samples ( n = 7 of 304) originated from calves born to vaccinated cows. Postcolostral positive serum samples ( n = 11 of 13) originated mostly (60%) from calves born to non-vaccinated cows. Precolostral serum sampling can detect apparent fetal infections in a herd.

  4. Single-tier testing with the C6 peptide ELISA kit compared with two-tier testing for Lyme disease.

    PubMed

    Wormser, Gary P; Schriefer, Martin; Aguero-Rosenfeld, Maria E; Levin, Andrew; Steere, Allen C; Nadelman, Robert B; Nowakowski, John; Marques, Adriana; Johnson, Barbara J B; Dumler, J Stephen

    2013-01-01

    For the diagnosis of Lyme disease, the 2-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time, and labor; and subjectivity in the interpretation of immunoblots. In this study, the diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with 2-tier testing. The results showed that the C6 ELISA was significantly more sensitive than 2-tier testing with sensitivities of 66.5% (95% confidence interval [CI] 61.7-71.1) and 35.2% (95% CI 30.6-40.1), respectively (P < 0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to 2-tier testing in sera from Lyme disease patients with early neurologic manifestations (88.6% versus 77.3%, P = 0.13) or arthritis (98.3% versus 95.6%, P = 0.38). The specificities of C6 ELISA and 2-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (P < 0.05, 95% CI surrounding the 0.6 percentage point difference of 0.04 to 1.15). In conclusion, using a reference standard of 2-tier testing, the C6 ELISA as a single-step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with 2-tier testing in routine clinical practice. Copyright © 2013 Elsevier Inc. All rights reserved.

  5. Seroprevalence of viral and bacterial diseases among the bovines in Himachal Pradesh, India

    PubMed Central

    Katoch, Shailja; Dohru, Shweta; Sharma, Mandeep; Vashist, Vikram; Chahota, Rajesh; Dhar, Prasenjit; Thakur, Aneesh; Verma, Subhash

    2017-01-01

    Aim: The study was designed to measure the seroprevalence of viral and bacterial diseases: Infectious bovine rhinotracheitis, bovine viral diarrhea, bovine leukemia, bovine parainfluenza, bovine respiratory syncytial disease, brucellosis, and paratuberculosis among bovine of Himachal Pradesh during the year 2013-2015. Materials and Methods: The serum samples were collected from seven districts of state, namely, Bilaspur, Kangra, Kinnaur, Lahul and Spiti, Mandi, Sirmour, and Solan. The samples were screened using indirect ELISA kits to measure the seroprevalence of viral and bacterial diseases. Results: The overall seroprevalence of infectious bovine rhinotracheitis was 24.24%, bovine viral diarrhea 1.52%, bovine leukemia 9.09%, bovine parainfluenza 57.58%, bovine respiratory syncytial disease 50%, brucellosis 19.69%, and paratuberculosis 9.09% in Himachal Pradesh. The seroprevalence of bovine rhinotracheitis, bovine leukemia, bovine parainfluenza, bovine respiratory syncytial disease, and paratuberculosis in the state varied significantly (p<0.01) while was insignificant for bovine viral diarrhea and brucellosis (p>0.01). Multiple seropositivity has been observed in this study. Bovine parainfluenza virus 3 was observed commonly in mixed infection with almost all viruses and bacteria under study. Conclusion: The viral and bacterial diseases are prevalent in the seven districts of Himachal Pradesh investigated in the study. Therefore, appropriate management practices and routine vaccination programs should be adopted to reduce the prevalence of these diseases. PMID:29391682

  6. Comparison of a commercial bovine pregnancy-associated glycoprotein ELISA test and a pregnancy-associated glycoprotein radiomimmunoassay test for early pregnancy diagnosis in dairy cattle.

    PubMed

    Karen, Aly; Sousa, Noelita Melo De; Beckers, Jean-François; Bajcsy, Árpád Csaba; Tibold, János; Mádl, István; Szenci, Ottó

    2015-08-01

    The present study aimed to compare the accuracy of a commercial PAG-ELISA test (Bovine Preg Test 29) and bovine pregnancy-associated glycoprotein radioimmunoassay (PAG-RIA) for diagnosing pregnancy at Day 28 after insemination in dairy cows. Transrectal ultrasonography (TRUS) was performed in 100 Holstein-Friesian cows at Day 28 after artificial insemination (AI; Day 0) to diagnose pregnancy. After TRUS examination, blood sample was collected from the coccygeal vessels of each cow to measure the concentrations of bPAGs by PAG-RIA test and Bovine Preg Test 29. Milk samples were collected at Days 0, 21 and 28 for measurement of progesterone (P4) by ELISA test. The cows were re-examined by TRUS at Day 42 to confirm the pregnancy diagnoses. The actual gold standard was based on TRUS outcomes at Day 28 that agreed with the outcomes of PAG-RIA test or PAG-ELISA test. If the outcomes of TRUS at Day 28 and PAG-RIA test and PAG-ELISA test did not agree, the gold standard was based on the outcome of TRUS at Day 42. Out of 100 inseminated cows, 41 were confirmed pregnant at Day 28 after AI. Based on the actual gold standard, the sensitivity of TRUS, PAG-ELISA and PAG-RIA tests for diagnosing pregnant cows at Day 28 were 92.7%, 90.2% and 100%, while the specificity of the three tests for diagnosing non-pregnant cows were 91.5%, 98.3% and 94.4%, respectively. The overall accuracy of the three tests were 92%, 95% and 97%, respectively. The degree of agreement (Kappa±S.E.) between PAG-RIA and PAG-ELISA test was 0.90 ±0.04. The degrees of agreement between PAG-RIA and PAG-ELISA and TRUS at Day 28 were 0.80±0.05 and 0.76±0.06, respectively. In conclusion, the commercial PAG-ELISA test is a highly accurate method for diagnosing early pregnancy in dairy cows on Day 28 after AI and may be used as an alternative method to the TRUS and the PAG-RIA test. Copyright © 2015 Elsevier B.V. All rights reserved.

  7. Development and validation of an ELISA kit (YF MAC-HD) to detect IgM to yellow fever virus.

    PubMed

    Basile, Alison Jane; Goodman, Christin; Horiuchi, Kalanthe; Laven, Janeen; Panella, Amanda J; Kosoy, Olga; Lanciotti, Robert S; Johnson, Barbara W

    2015-12-01

    Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas. Published by Elsevier B.V.

  8. Evaluation of a commercial ELISA kit for detection of antibodies against Toxoplasma gondii in serum, plasma and meat juice from experimentally and naturally infected sheep

    PubMed Central

    2013-01-01

    Background Toxoplasmosis is one of the most common food borne zoonoses worldwide, and can be a serious life-threatening disease in the congenitally infected fetus and in immunosupressed patients. Among food animals, sheep along with goats and pigs possess the highest incidence of T. gondii cysts in meat, and play a major role as a source of human infection. Methods In this study, a new commercial ELISA kit (PrioCHECK® Toxoplasma Ab SR, Prionics Schlieren-Zurich, Switzerland) for the detection of anti-T. gondii antibodies in serum, plasma and meat juice of sheep, was evaluated by comparing it with the indirect fluorescent antibody test (IFAT), indirect haemagglutination test (IHA) and real-time PCR, on samples from experimentally inoculated and naturally exposed sheep. Results The commercial ELISA detected the infection status in 50% and 100% of sheep orally inoculated with 10,000 T. gondii oocysts (n = 6), from two or three weeks post infection (wpi), respectively, both on serum and plasma samples. Meat juice from all experimentally inoculated sheep collected at slaughter (12 wpi) showed positive ELISA values. In naturally exposed sheep (n = 396), the ELISA showed a very good agreement with IFAT (kappa = 0.91-1.0) and IHA (kappa = 0.96-1.0) performed on serum; and a positive correlation was observed between ELISA values and IFAT titers. By a Receiver Operating Characteristics (ROC) curve analysis, the commercial ELISA had relative sensitivities between 93.33% and 100%, and relative specificities between 96.87% and 100% respect to IFAT and IHA, depending on the considered cut-off value and animal groups tested. Furthermore, the ELISA correctly recognized all animals reacting positive in real-time PCR. The ELISA results on meat juice agreed with those on serum samples in all experimentally inoculated animals, and in 94 out of 96 (97.9%) naturally exposed sheep, when meat juice was tested at a 1:10 dilution. Conclusion The commercial ELISA kit

  9. Accuracy of a point-of-care ELISA test kit for predicting the presence of protective canine parvovirus and canine distemper virus antibody concentrations in dogs.

    PubMed

    Litster, A L; Pressler, B; Volpe, A; Dubovi, E

    2012-08-01

    Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples.

    PubMed

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-07-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs.

  11. Development of an interleukin (IL)-33 sandwich ELISA kit specific for mature IL-33.

    PubMed

    Kim, Eunsom; Kwak, Areum; Jhun, Hyunjhung; Lee, Siyoung; Jo, Seunghyun; Lee, Jongho; Kang, Tae-Bong; Her, Erk; Bae, Suyoung; Lee, Youngmin; Kim, Soohyun

    2016-01-01

    Interleukin (IL)-33 is an inflammatory cytokine and belongs to the IL-1 family of cytokines. There are eleven members of the IL-1 family of cytokines and all have important roles in host defense against infections. Their levels are increased during infection and in various auto-inflammatory diseases. IL-33 is also associated with autoimmune diseases such as asthma, atopic dermatitis, rheumatoid arthritis, and atherosclerosis. IL-33 receptors consist of IL-1R4 and IL-1R3 to induce both Th1 and Th2 type immune response. Here we present the development of monoclonal antibodies (mAbs) against human mature IL-33. Recombinant human mature IL-33 protein was expressed in E. coli and purified by multi-step affinity chromatography. The human IL-33 activity was examined in HMC-1 and Raw 264.7 cells. Mice were immunized with the biologically active mature IL-33 to generate mAb against IL-33. The anti-IL-33 mAb (clone/4) was used as a capture antibody for a sandwich enzyme-linked immunosorbent assay (ELISA). This assay detects mature IL-33 with a high sensitivity (80 pg/mL) but does not recognize the biologically inactive precursor IL-33. This article describes the methods for a newly developed IL-33 ELISA kit that is specific for mature IL-33 and may be used to analyze bioactive mature IL-33 in various immunological diseases.

  12. Diagnostic performance of an indirect enzyme-linked immunosorbent assay (ELISA) to detect bovine leukemia virus antibodies in bulk-tank milk samples

    PubMed Central

    Nekouei, Omid; Durocher, Jean; Keefe, Greg

    2016-01-01

    This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469

  13. Development and validation of an Enzyme Linked Immunosorbent Assay (ELISA) test for the diagnosis of toxoplasmosis in Sri Lanka.

    PubMed

    Iddawela, D; Ehambaram, K; Kumarasiri, P V; Wijesundera, S

    2015-09-01

    ELISA is the most widely used form of diagnosis for toxoplasmosis. Several commercial kits are currently used in Sri Lanka. However, these kits are not affordable in resource-limited settings. Objectives Aim of this study was to develop a cost effective in-house ELISA for the detection of Toxoplasma antibody and to estimate the diagnostic accuracy compared to a commercial kit. Vero cell lines were inoculated with tachyzoites and harvested after 2-6 days and sonicated to obtain somatic antigen. The antigen was used as coating material in ELISA to detect antibodies against T. gondii in patient sera. Hundred and three patients' sera were analysed by in-house ELISA and kit ELISA. Optical density (OD) values were analysed statistically. Toxoplasma IgG avidity test was used to determine the chronic and acute phase of infection. The optimum working dilutions for antigen was 0.846 μg/ml and for serum 1 in 100. The optimal cut-off values for the in-house ELISA within the range 0.85 to 0.98 at which the sensitivity was 95.3% and specificity was 98.3. The OD values of in-house ELISA were compared with OD values of kit ELISA and the results showed strong correlation between the two tests. The results of our study demonstrated that our in-house ELISA for detection of T. gondii antibody was as sensitive and specific as the commercial kit used in this study. Thus, the in-house ELISA is a useful, costeffective tool for diagnostic and screening purposes.

  14. Development of a test for bovine tuberculosis in cattle based on measurement of gamma interferon mRNA by real-time PCR.

    PubMed

    Gan, W; Zhou, X; Yang, H; Chen, H; Qiao, J; Khan, S H; Yang, L; Yin, X; Zhao, D

    2013-08-03

    The infection status of cattle for bovine tuberculosis (bTB) was determined by real-time PCR, comparing the levels of IFN-γ mRNA in blood cultures stimulated with either bovine or avian tuberculin with non-stimulated control (phosphate buffer saline, PBS) blood culture. Totally, 137 cattle were tested to validate the assay, in which 54 were IFN-γ real-time quantitative PCR (RT-qPCR) positive, while the remaining 83 were found negative. Meanwhile, the IFN-γ ELISA test was carried out using the Bovigam IFN-γ detection ELISA kit and these results were used as a standard. The results of the single intradermal tuberculin tests (SIDT) and IFN-γ RT-qPCR tests were compared and revealed that the RT-qPCR correlated better with the ELISA and its accuracy was higher than SIDT. This indicates the RT-qPCR is a useful diagnostic method for bTB in cattle. However, several limitations remain for our approach, such as lack of a TB lesions or postmortem test results as a gold standard. Further improvements should be made in the future to increase accuracy of diagnosis of bTB in cattle.

  15. Comparison of six commercial tick-borne encephalitis IgM and IgG ELISA kits and the molecular characterization of their antigenic design.

    PubMed

    Velay, Aurélie; Solis, Morgane; Barth, Heidi; Sohn, Véronique; Moncollin, Anne; Neeb, Amandine; Wendling, Marie-Josée; Fafi-Kremer, Samira

    2018-04-01

    Tick-borne encephalitis virus (TBEV) diagnosis is mainly based on the detection of viral-specific antibodies in serum. Several commercial assays are available, but published data on their performance remain unclear. We assessed six IgM and six IgG commercial enzyme-linked immunosorbent assay (ELISA) kits (ELISA-1 through ELISA-6) using 94 samples, including precharacterized TBEV-positive samples (n=50) and -negative samples (n=44). The six manufacturers showed satisfactory sensitivity and specificity and high overall agreement for both IgM and IgG. Three manufacturers showed better reproducibility and were the most sensitive (100%) and specific (95.5-98.1%) for both IgM and IgG. Two of them were also in agreement with the clinical interpretation in more than 90% of the cases. All the assays use inactivated virus as antigen, with strains showing approximately 94% homology at the amino acid level. The antigenic format of the assays was discussed to further improve this TBEV diagnostic tool. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Test/QA Plan for Verification of Microcystin Test Kits

    EPA Science Inventory

    Microcystin test kits are used to quantitatively measure total microcystin in recreational waters. These test kits are based on enzyme-linked immunosorbent assays (ELISA) with antibodies that bind specifically to microcystins or phosphate activity inhibition where the phosphatas...

  17. Comparison of commercial enzyme-linked immunosorbent assay kits with agar gel precipitation and hemagglutination-inhibition tests for detecting antibodies to avian influenza viruses.

    PubMed

    Shiraishi, Rikiya; Nishiguchi, Akiko; Tsukamoto, Kenji; Muramatsu, Masatake

    2012-09-01

    We evaluated the utility of 5 commercial enzyme-linked immunosorbent assay (ELISA) kits for detecting antibodies to avian influenza viruses. The sensitivities and specificities of the ELISA kits were compared with those of the agar gel precipitation (AGP) and hemagglutination-inhibition (HI) tests. The results suggest that some ELISA kits might not be suitable for monitoring during the early stages of avian influenza virus infections. Therefore, ELISA kits should only be used in conjunction with a profound knowledge about monitoring of avian influenza.

  18. Development of in-house ELISA for detection of chloramphenicol in bovine milk with subsequent confirmatory analysis by LC-MS/MS.

    PubMed

    Chughtai, Muhammad I; Maqbool, Uzma; Iqbal, Mazhar; Shah, Muhammad S; Fodey, Terence

    2017-12-02

    This study was undertaken to develop and validate direct competitive ELISA for the determination of chloramphenicol residues in bovine milk. Antisera and an enzyme-tracer for chloramphenicol were prepared and used to develop an ELISA with inhibition concentrations, IC 20 and IC 50 , of 0.09 and 0.44 ng mL -1 , respectively. Milk samples were spiked with standards equivalent to 0, 0.2, 0.3, 0.5, 1.0 & 1.5 ng mL -1 and extracted in methanol. The mean recoveries were found to be 73-100% with coefficient of variance 7-11%. The decision limit (CCα) and detection capability (CCβ) were calculated as 0.10 and 0.12 ng mL -1 , respectively. The results were found comparable with the commercial ELISA, having recoveries of 87 to 100%, CCα 0.09 ng mL -1 and CCβ 0.12 ng mL -1 . As per Commission Decision 2002/657/EC, in-house ELISA was further validated by using LC-MS/MS. Mass spectral acquisition was done by using electrospray ionization in the negative ion mode applying single reaction monitoring of the diagnostic transition reaction for CAP (m/z 152, 194 and 257). The calibration curve showed good linearity in concentrations from 0.025 to 1.6 ng mL -1 with correction coefficient 0.9902. The mean recoveries were found to be 88 to 100%. The CCα was calculated as 0.057 ng mL -1 and CCβ 0.10 ng mL -1 . Since CCα and CCβ are less than half of the MRPL (0.15 ng mL -1 ), the test was found suitable for screening and quantification of CAP residues in bovine milk samples. Results of surveillance studies indicated that out of 31 analyzed milk samples, 12.9% samples were found with CAP residues but only 3.2% samples were declared positive with maximum concentration 0.31 ng mL -1 , slightly above the MRPL.

  19. [Comparison of Dengue viral nonstructural protein 1 antigen testing kits].

    PubMed

    Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F

    2018-02-06

    Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2

  20. Limits of diagnostic accuracy of anti-hepatitis C virus antibodies detection by ELISA and immunoblot assay.

    PubMed

    Suslov, Anatoly P; Kuzin, Stanislav N; Golosova, Tatiana V; Shalunova, Nina V; Malyshev, Nikolai A; Sadikova, Natalia V; Vavilova, Lubov M; Somova, Anna V; Musina, Elena E; Ivanova, Maria V; Kipor, Tatiana T; Timonin, Igor M; Kuzina, Lubov E; Godkov, Mihail A; Bajenov, Alexei I; Nesterenko, Vladimir G

    2002-07-01

    When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.

  1. Evaluation of rapid post-mortem test kits for bovine spongiform encephalopathy (BSE) screening in Japan: Their analytical sensitivity to atypical BSE prions.

    PubMed

    Hagiwara, Ken'ichi; Iwamaru, Yoshifumi; Tabeta, Naoko; Yokoyama, Takashi; Tobiume, Minoru

    2017-03-04

    A classical type of bovine spongiform encephalopathy (C-BSE), recognized in 1987, had a large impact on public health due to its zoonotic link to variant Creutzfeldt-Jakob disease by the human consumption of dietary products contaminated with the C-BSE prion. Thus, a number of countries implemented BSE surveillance using rapid post-mortem test kits that were approved for detection of the C-BSE prion in the cattle brain. However, as atypical BSE (L- and H-BSE) cases emerged in subsequent years, the efficacy of the kits for the detection of atypical BSE prions became a matter of concern. In response to this, laboratories in the European Union and Canada evaluated the kits used in their countries. Here, we carried out an evaluation study of NippiBL®, a kit currently used for BSE screening in Japan. By applying the kit to cattle brains of field cases of C-BSE and L-BSE, and an experimental case of H-BSE, we showed its comparable sensitivities to C, L-, and H-BSE prions, and satisfactory performance required by the European Food Safety Authority. In addition to NippiBL®, two kits (TeSeE® and FRELISA®) formerly used in Japan were effective for detection of the L-BSE prion, although the two kits were unable to be tested for the H-BSE prion due to the discontinuation of domestic sales during this study. These results indicate that BSE screening in Japan is as effective as those in other countries, and it is unlikely that cases of atypical BSE have been overlooked.

  2. Competitive and double antibody sandwich ELISA for the quantification of lactoferrins by using monoclonal and chicken egg yolk IgY antibodies.

    PubMed

    Sunwoo, Hoon; Gujral, Naiyana; Suresh, Mavanur

    2011-01-01

    Two effective competitive and double antibody sandwich ELISA based on monoclonal (MAb) and chicken egg yolk IgY antibodies were developed to determine lactoferrin (LF) content in infant and milk formulas. Leghorn laying hens were immunized with purified bovine and human LFs to produce anti-bovine LF and anti-human LF IgY antibody in the egg yolk. After 5-8 weeks of the immunization, anti-LF IgY was extracted and analyzed by ELISA. Specific IgY antibodies against LFs cross reacted with human and bovine LFs, examined by ELISA and western-blot assay. Such cross-reactivity suggested the presence of common antigenic determinants between human and bovine LFs. An indirect competitive ELISA was preferred to quantify LF in milk and infant formulas, since the range of detection is 3.125-50 μg/mL, which is broader compared to the biotinylated ELISA system (5-50 ng/mL). As per the indirect competitive ELISA system, IgY at a concentration of the 150 μg/mL was incubated with various concentrations of bovine LF ranged from 0.003-100 μg/mL. The immunoassay was used to estimate the total bovine LF content in the milk samples and infant formulas, ranging from 49.28-80.96 μg/mL and 29.92-60.00 μg/mL, respectively.

  3. Serological and coprological analyses for the diagnosis of Fasciola gigantica infections in bovine hosts from Sargodha, Pakistan.

    PubMed

    Rehman, T; Khan, M N; Abbas, R Z; Babar, W; Sikandar, A; Zaman, M A

    2016-07-01

    A serological and coprological survey of fasciolosis was conducted in bovine hosts from the Sargodha district, Pakistan using excretory-secretory (ES) antigens of Fasciola gigantica from cattle and buffaloes. Livers, faecal and blood samples of 146 cattle and 184 buffaloes were collected from slaughterhouses and examined for the presence of any Fasciola in bile ducts and ova in faeces. Serum was separated. ES antigens were prepared by incubating adult Fasciola in phosphate-buffered saline for 6-8 h and then filtering using a 0.22-μm syringe filter. Checkerboard titration was performed and optimum concentrations of antigen and serum were determined. Sero-prevalence was found to be 50.00 and 38.35% in buffalo and cattle, respectively. Using liver examination as the gold standard, enzyme-linked immunosorbent assay (ELISA) sensitivity was found to be 100% in both buffalo and cattle as compared with that of coprological examination in buffalo (61.79%) and cattle (54.54%). This indigenous ELISA was also highly specific, with values of 96.84 and 98.90% in buffalo and cattle, respectively. Positive predictive values were calculated as 96.74 and 98.21% in buffalo and cattle, respectively, while negative predictive values were 100%. For the validation of indigenous ELISA in field surveys, faecal and blood samples were collected from six sub-districts (tehsils) in the district of Sargodha. Sera were screened for the presence of anti-fasciola antibodies using both the indigenous and commercial ELISA kits. While both kits were equally sensitive, the indigenous ELISA was found to be more specific. The highest prevalence of fasciolosis was found in December, as ascertained using both serological and coprological examination. Significant differences were found in prevalences of fasciolosis in different sub-districts and age groups, together with feeding and watering systems.

  4. Effect of ELISA kit manufacturing process and incubation time on progesterone concentration measured in dog serum for ovulation diagnosis - Short communication.

    PubMed

    Thuróczy, Julianna; Reiczigel, Jenő; Balogh, Lajos

    2016-09-01

    Twenty-two serum samples of healthy bitches were tested with the frozen and lyophilised version of the same ELISA kit (Quanticheck, Faculty of Veterinary Science, Budapest, Hungary). Samples were chosen on the basis of their progesterone (P4) concentrations, which were between 1.00 and 20.00 ng/mL. As it is well known, this range has the highest clinical relevance in ovulation diagnosis. Both types of microplates were read at 15-min intervals from the 15th until the 90th minute (min) of incubation, and the results were compared with those of frozen plates at 60 min of incubation as 100 percent. Lyophilised microplates gave on average 18 percent higher results than the frozen version at equal incubation times. The highest difference between lyophilised and frozen samples was observed at 45 and 60 min of incubation. Ninety-four percent of the reaction in the frozen microplate occurred in the first 15 min, and during the subsequent 30 min the reaction seemingly stopped. After the 45th min of incubation, this 94 percent increased to 108 percent in the subsequent 30 min, which remained the final approximate result at the end of the 90 min of incubation. In contrast to the frozen microplate, the measured concentration increased continuously in the lyophilised version and reached the highest level at the 60th min. The results of the lyophilised microplate reached the same level at 30 min of incubation as those of the frozen version at 60 min. In conclusion, a mechanical increase or decrease of the incubation time does not generate a linear change in the test results. This study demonstrated that the results of a series of samples collected from the same bitch cannot be compared if they are measured with different laboratory methods or different ELISA kits.

  5. The Effect of Different Methods of Fermentation on the Detection of Milk Protein Residues in Retail Cheese by Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L

    2017-11-01

    Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain

  6. Evaluation of HIV/AIDS diagnostics kits and formulation of a testing strategy for Pakistan.

    PubMed

    Waheed, Usman; Hayat, Khizar; Ahmad, Bashir; Waheed, Yasir; Zaheer, Hasan Abbas

    2013-04-01

    Rapid diagnosis of HIV/AIDS enables the development of prevention and treatment programmes but accurate, reliable and cost effective testing strategies should be used for testing of HIV/AIDS from a large population. To evaluate the performance and effectiveness of three assays for the diagnosis of HIV in comparison with Western blot and to formulate an alternative cost-effective confirmatory approach for HIV diagnosis. 472 specimens (serum) from a Pakistani population were evaluated. Two rapid HIV testing kits (Capillus, SD Bioline) and one ELISA (Vironostika Ag/Ab) kit were used to detect HIV. Results were compared with Western blot against which sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of all HIV assays were assessed. 280/472 (59.3%) of the samples were positive for antibodies against purified HIV-1 viral proteins. The sensitivity of SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100) while that of anti-HIV Capillus™ kit was 94.6% (95% CI; 91-96.8). The specificity of the Vironostika ELISA and anti-HIV Capillus™ kit was 100% (95% CI; 97-100) while specificity of SD Bioline was 98.4% (95% CI; 95-99). PPV was 100% (95% CI; 98-100%) for the anti-HIV Capillus™ and Vironostika ELISA and 98.9% (95% CI; 96-99%) for SD Bioline. NPV for SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100%) and 92.7% for anti-HIV Capillus™ (95% CI; 88-96%). The sensitivity and specificity of all three kits were satisfactory compared to Western blot and could be used for effective diagnosis of HIV/AIDS in Pakistani population. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. [Development of a SPA-ELISA method for detecting anti-coronavirus IgG antibodies in serum samples from fulvous fruit bats].

    PubMed

    Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi

    2008-05-01

    To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.

  8. Establishment and optimization of monoclonal antibody-based heterologous dcELISA for 19-nortestosterone residue in bovine edible tissue.

    PubMed

    Jiang, Jinqing; Zhang, Haitang; Li, Guangling; Yang, Xuefeng; Li, Renfeng; Wang, Ziliang; Wang, Jianhua

    2012-04-01

    This paper presents the generation of monoclonal antibodies (mAbs) with high specificity against 19-nortestosterone (NT) through cell fusion procedures, and the development of mAb-based heterologous direct competitive enzyme-linked immunoabsorbent assay (dcELISA) methods to detect NT residue using one of these hybridomas (clone 3B8-E6). Under optimal experimental conditions, this assay exhibited a working range of 0.004 to 19 ng/mL with IC₅₀ and limit of detection values of 0.28 and 0.002 ng/mL, respectively, when it was run in 0.01M phosphate-buffered saline (pH 7.4). Except for minor cross-reactivity with β-boldenone (6.9%) and trenbolone (1.2%), other interference to the assay was negligible (<0.05%). No significant differences (P > 0.05) were found for IC₅₀ values when the pH of the assay buffer ranged from 6 to 8 and phosphate ion concentration was less than 20 mM. The dcELISA can tolerate higher concentrations of methanol than other organic solvents tested. When applied to bovine sample, the correlation coefficients (R) of the dcELISA and GC-MS data were 0.9918 in muscle, 0.9834 in liver, and 0.9976 in kidney. Therefore, this assay has the potential to be incorporated into a quantitative monitoring program for the rapid screening of NT residue in food. © 2012 Institute of Food Technologists®

  9. Increased Sensitivity of HIV-1 p24 ELISA Using a Photochemical Signal Amplification System.

    PubMed

    Bystryak, Simon; Santockyte, Rasa

    2015-10-01

    In this study we describe a photochemical signal amplification method (PSAM) for increasing of the sensitivity of enzyme-linked immunosorbent assay (ELISA) for determination of HIV-1 p24 antigen. The photochemical signal amplification method is based on an autocatalytic photochemical reaction of a horseradish peroxidase (HRP) substrate, orthophenylenediamine (OPD). To compare the performance of PSAM-boosted ELISA with a conventional colorimetric ELISA for determination of HIV-1 p24 antigen we employed a PerkinElmer HIV-1 p24 ELISA kit, using conventional ELISA alongside ELISA + PSAM. In the present study, we show that PSAM technology allows one to increase the analytical sensitivity and dynamic range of a commercial HIV-1 p24 ELISA kit, with and without immune-complex disruption, by a factor of approximately 40-fold. ELISA + PSAM is compatible with commercially available microtiter plate readers, requires only an inexpensive illumination device, and the PSAM amplification step takes no longer than 15 min. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods.

  10. [Double-antigen sandwich ELISA for detecting Aspergillus fumigatus anti-Afmp1cr and Afmp2cr antibodies].

    PubMed

    Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan

    2014-05-01

    To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.

  11. Low sensitivity and frequent cross-reactions in commercially available antibody detection ELISA assays for Taenia solium cysticercosis.

    PubMed

    Garcia, Hector H; Castillo, Yesenia; Gonzales, Isidro; Bustos, Javier A; Saavedra, Herbert; Jacob, Louis; Del Brutto, Oscar H; Wilkins, Patricia P; Gonzalez, Armando E; Gilman, Robert H

    2018-01-01

    To evaluate the diagnostic performance of two commercially available ELISA kits, Novalisa ® and Ridascreen ® , for the detection of antibodies to Taenia solium, compared to serological diagnosis of neurocysticercosis (NCC) by LLGP-EITB (electro-immunotransfer blot assay using lentil-lectin purified glycoprotein antigens). Archive serum samples from patients with viable NCC (n = 45) or resolved, calcified NCC (n = 45), as well as sera from patients with other cestode parasites (hymenolepiasis, n = 45 and cystic hydatid disease, n = 45), were evaluated for cysticercosis antibody detection using two ELISA kits, Novalisa ® and Ridascreen ® . All NCC samples had previously tested positive, and all samples from heterologous infections were negative on LLGP-EITB for cysticercosis. Positive rates were calculated by kit and sample group and compared between the two kits. Compared to LLGP-EITB, the sensitivity of both ELISA assays to detect specific antibodies in patients with viable NCC was low (44.4% and 22.2%), and for calcified NCC, it was only 6.7% and 4.5%. Sera from patients with cystic hydatid disease were highly cross-reactive in both ELISA assays (38/45, 84.4%; and 25/45, 55.6%). Sera from patients with hymenolepiasis cross-reacted in five cases in one of the assays (11.1%) and in only one sample with the second assay (2.2%). The performance of Novalisa ® and Ridascreen ® was poor. Antibody ELISA detection cannot be recommended for the diagnosis of neurocysticercosis. © 2017 John Wiley & Sons Ltd.

  12. Herd-level risk factors for bovine viral diarrhea infection in cattle of Tamil Nadu.

    PubMed

    Kumar, Subbiah Krishna; Palanivel, K M; Sukumar, K; Ronald, B Samuel Masilamoni; Selvaraju, G; Ponnudurai, G

    2018-04-01

    A cross-sectional study was carried out to identify risk factors for bovine viral diarrhea virus (BVDV) infection in 62 randomly selected dairy herds which were tested for BVD serum antibodies by using an indirect ELISA kit (IDEXX). Results from the chi-square test analysis were interpreted by analyzing by chi-square test. A sum of 500 sera samples were screened and 66 animals (13.20%) showed positive for BVDV antibody. Within herd, BVD seroprevalence was 12-65%. This study concluded that epidemiological risk factors like location, herd size, housing patterns like, tail to tail system, roofing pattern, distance between the manure pit and farm, and distance between farms were significantly associated with BVDV serological status (P < 0.05).

  13. Evaluation of SD BIOLINE H. pylori Ag rapid test against double ELISA with SD H. pylori Ag ELISA and EZ-STEP H. pylori Ag ELISA tests.

    PubMed

    Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene

    2018-01-01

    Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values < 0.05 were taken statistically significant. Stool and serum samples were collected from 201 dyspeptic patients and analysed. The sensitivity, specificity, positive and negative predictive values of the SD BIOLINE H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.

  14. Detection of Toxoplasma gondii in raw caprine, ovine, buffalo, bovine, and camel milk using cell cultivation, cat bioassay, capture ELISA, and PCR methods in Iran.

    PubMed

    Dehkordi, Farhad Safarpoor; Borujeni, Mohammad Reza Haghighi; Rahimi, Ebrahim; Abdizadeh, Rahman

    2013-02-01

    This study was conducted to determine the presence of Toxoplasma gondii in animal milk samples in Iran. From a total of 395 dairy herds in three provinces of Iran, 66 bovine, 58 ovine, 54 caprine, 33 buffalo, and 30 camel herds were studied, and from these parts of Iran, 200 bovine, 185 ovine, 180 caprine, 164 buffalo, and 160 camel milk samples were collected from various seasons. Samples were tested for Toxoplasma gondii by cell line culture, enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR) technique. Only the results of cell line cultivation were confirmed by bioassay in cat. Results indicated that all herds were infected with Toxoplasma gondii. The culture method showed that 51 out of 889 milk samples (5.73%) were positive for Toxoplasma gondii, and all 51 positive culture results were positive with bioassay in cat. The Fars province had the highest prevalence of Toxoplasma gondii (6.84%). The ELISA test showed that 41 milk samples (4.61%) were positive for the presence of Toxoplasma gondii, while the PCR showed that 46 milk samples were positive for Toxoplasma gondii. The results showed higher sensitivity of PCR and higher specificity of ELISA. Caprine had the highest (10%) and camel had the lowest (3.12%) prevalence rate of parasite. The summer season had the highest (76.47%) but winter (3.92) had the lowest incidence of Toxoplasma gondii. This study is the first prevalence report of direct detection of Toxoplasma gondii in animal milk samples in Iran.

  15. Comparative diagnostic efficacy of recombinant LLO and PI-PLC-based ELISAs for detection of listeriosis in animals.

    PubMed

    Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B

    2017-06-01

    The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (p<0.05). On the contrary, rPI-PLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Bovine single chain Fv antibody inhibits bovine herpesvirus-1 infectivity by targeting viral glycoprotein D.

    PubMed

    Xu, Jian; Wu, Jing; Jiang, Bo; He, Houjun; Zhang, Xixi; Li, Xiaoyang; Yang, Dawei; Huang, Xiufen; Sealy, Joshua E; Iqbal, Munir; Li, Yongqing

    2017-12-01

    Glycoprotein D (gD) of bovine herpesvirus-1 (BoHV-1) is essential for attachment and penetration of cells during infection and is a major target for neutralizing antibodies during an adaptive immune response. Currently there are no recombinant antibodies capable of binding gD epitopes for use in treating BoHV-1 infection. In this study, a bovine scFv gene derived from a hybridoma secreting monoclonal antibodies (McAbs) against the amino acid motif MEESKGYEPP of gD was expressed in E. coli. Molecular modeling, western blot and ELISA analysis showed that this scFv had a high affinity for BoHV-1 gD, with a Kd of 161.2 ± 37.58 nM and for whole BoHV-1 virus, with a Kd of 67.44 ± 16.99 nM. In addition, this scFv displayed a high affinity for BoHV-1 antigen in an ELISA and competed with BoHV-1 anti-serum in a competitive ELISA. Immunofluorescence assay (IFA) and laser confocal microscopy showed that this scFv could efficiently bind to and be internalized by BoHV-1 infected Madin-Darby bovine kidney (MDBK) cells. Importantly, this scFv was shown to inhibit BoHV-1 infectivity and to reduce the number of viral plaques by blocking viral attachment to MDBK cells. Our study suggests that this bovine single-chain antibody could be developed for use as a diagnostic and therapeutic agent against BoHV-1 infection in cattle.

  17. Evaluation of ELISA tests specific for Shiga toxin 1 and 2 in food and water samples

    USDA-ARS?s Scientific Manuscript database

    Two enzyme-linked immunosorbent assay (ELISA) kits were evaluated for their effectiveness in detecting and differentiating between Shiga toxin 1 and 2 (Stx1 and Stx2) produced by Shiga toxin-producing E. coli (STEC) inoculated into food and water samples. Each kit incorporated monoclonal antibodies ...

  18. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India.

    PubMed

    Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar

    2012-11-26

    HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false

  19. Performance and diagnostic usefulness of commercially available enzyme linked immunosorbent assay and rapid kits for detection of HIV, HBV and HCV in India

    PubMed Central

    2012-01-01

    Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful

  20. Matrix effect and cross-reactivity of select amphetamine-type substances, designer analogues, and putrefactive amines using the Bio-Quant direct ELISA presumptive assays for amphetamine and methamphetamine.

    PubMed

    Apollonio, Luigino G; Whittall, Ian R; Pianca, Dennis J; Kyd, Jennelle M; Maher, William A

    2007-05-01

    The aim of this study was to evaluate the Bio-Quant Direct ELISA assays for amphetamine and methamphetamine in the routine presumptive screening of biological fluids. Standard concentration curves of the target analytes were assayed to assess sensitivity, and known concentrations of common amphetamine-type substances (ephedrine, pseudoephedrine, phentermine), designer analogues (MDA, MDMA, MDEA, MBDB, PMA, 4-MTA, 2CB), and putrefactive amines (phenylethylamine, putrescine, tryptamine, tyramine) were analyzed to determine cross-reactivity. Results of the standard curve studies show the capacity of both Direct ELISA kits to confidently detect down to 3 ng/mL interday (PBS matrix; CVs 6.3-15.5%). Cross-reactivity relative to that of 50 ng/mL preparations of the target compounds demonstrated that the Direct ELISA kit for amphetamine also detected MDA (282%), PMA (265%), 4-MTA (280%), and phentermine (61%), and the Direct ELISA for methamphetamine also assayed positive for MDMA (73%), MDEA (18%), pseudoephedrine (19%), MBDB (8%), and ephedrine (9%). Matrix studies demonstrated that both ELISA kits could be applied to screening of blood, urine, and saliva to a concentration of 6 ng/mL or lower. In conclusion, the Bio-Quant Direct ELISA kits for amphetamine and methamphetamine are fast and accurate and have demonstrated themselves to be useful tools in routine toxicological testing.

  1. Decline of antibody response in indirect ELISA tests during the periparturient period caused diagnostic gaps in Coxiella burnetii and BVDV serology in pluriparous cows within a Holstein dairy herd.

    PubMed

    Walraph, J; Zoche-Golob, V; Weber, J; Freick, M

    2018-06-01

    In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Evaluation of a recombinant LigB protein of Leptospira interrogans serovar Canicola in an enzyme-linked immunosorbent assay for the serodiagnosis of bovine leptospirosis.

    PubMed

    Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K

    2010-06-01

    A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.

  3. Evaluation of recombinant LigB antigen-based indirect ELISA and latex agglutination test for the serodiagnosis of bovine leptospirosis in India.

    PubMed

    Deneke, Yosef; Sabarinath, T; Gogia, Neha; Lalsiamthara, Jonathan; Viswas, K N; Chaudhuri, Pallab

    2014-08-01

    Leptospirosis is a zoonotic disease caused by pathogenic spirochetes of the genus Leptospira, causing febrile infection characterized by multi-organ failure in humans and animals. Leptospiral Ig-like protein B (LigB) is a surface-expressed antigen that mediates host cell invasion or attachment. In this study, N-terminal conserved region of LigB protein (46 kDa) was evaluated for its diagnostic potential to detect anti-leptospiral antibodies in the sera of various animal species. Dot blot analysis revealed immunoreactivity of Leptospira-positive sera of cattle, buffalo, dog, sheep and goat to purified LigB protein. We have analyzed 1126 bovine serum samples, collected from Northern and Eastern part of India, by microscopic agglutination test (MAT) and recombinant LigB (rLigB) based ELISA and latex agglutination test (LAT). The sensitivity of rLigB based ELISA for 554 MAT positive sera was 96.9% and the specificity with 572 MAT negative sera was 91.08% whereas LAT showed sensitivity and specificity of 93.68% and 92.31%, respectively. Kappa values of 0.879 and 0.860 for recombinant antigen based ELISA and LAT indicate excellent agreement with the gold standard serological test, MAT, for the detection of anti-leptospiral antibodies in sera. Further, LAT based on rLigB antigen is a simple and rapid test, suitable for serodiagnosis of leptospirosis under field conditions, owing to its portability and longer shelf life. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Evaluation of the recombinant LipL32 in enzyme-linked immunosorbent assay for the serodiagnosis of bovine leptospirosis.

    PubMed

    Bomfim, Maria Rosa Quaresma; Ko, Albert; Koury, Matilde Cota

    2005-08-10

    The recombinant leptospiral protein LipL32 was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLipL32 IgG ELISA). The microscopic agglutination test (MAT) of 150 serum samples from cattle suspected of leptospirosis showed that 125 (83.3%) samples had positive reciprocal agglutination titres, which ranged from 100 to 1600. The highest titres were observed for the serovars Hardjoprajitno and Bratislava. In the rLipL32 IgG ELISA, 83.3% of the samples were positive. The sensitivity of IgG ELISA for 125 bovine sera, which had MAT titres of greater than or equal to 100, was 100%. ELISA showed a specificity of 100% with 58 bovine sera, which were negative at a 1:50 dilution in the MAT for Leptospira interrogans serovars. When analytical specificity of the IgG ELISA was evaluted using 60 bovine serum samples from animals showing serum antibodies to other pathogens that cause abortion in cattle, such as Babesia sp., Anaplasma sp. and Brucella sp. and no cross-reaction was observed. The recombinant LipL32 IgG ELISA can be an alternative to the MAT for diagnosis of leptospiral infection in cattle.

  5. [Real-time PCR kits for the detection of the African Swine Fever virus].

    PubMed

    Latyshev, O E; Eliseeva, O V; Grebennikova, T V; Verkhovskiĭ, O A; Tsibezov, V V; Chernykh, O Iu; Dzhailidi, G A; Aliper, T I

    2014-01-01

    The results obtained using the diagnostic kit based on real-time polymerase chain reaction to detect the DNA of the African Swine Fever in the pathological material, as well as in the culture fluid, are presented. A high sensitivity and specificity for detection of the DNA in the organs and tissues of animals was shown to be useful for detection in the European Union referentiality reagent kits for DNA detection by real time PCR of ASFV. More rapid and effective method of DNA extraction using columns mini spin Quick gDNA(TM) MiniPrep was suggested and compared to the method of DNA isolation on the inorganic sorbent. High correlation of the results of the DNA detection of ASFV by real-time PCR and antigen detection results ASFV by competitive ELISA obtained with the ELISA SEROTEST/INGEZIM COMRAC PPA was demonstrated. The kit can be used in the veterinary services for effective monitoring of ASFV to contain, eliminate and prevent further spread of the disease.

  6. A Novel Blocking ELISA for Detection of Antibodies against Hepatitis E Virus in Domestic Pigs.

    PubMed

    Chen, Yiyang; Zhao, Qin; Liu, Baoyuan; Wang, Lizhen; Sun, Yani; Li, Huixia; Wang, Xinjie; Syed, Shahid Faraz; Zhang, Gaiping; Zhou, En-Min

    2016-01-01

    Hepatitis E virus (HEV) infects both humans and animals, with an overall human mortality rate generally less than 1%, but as high as 20% among pregnant women. HEV strains fall into 4 major genotypes. Zoonotic genotypes 3 and 4 associate with sporadic human and animal HEV cases in many industrialized countries. To date, collective evidence implicates pigs as the main HEV reservoir, justifying the importance of monitoring HEV infection rates in pig herds to prevent human illness. Due to the lack of a robust in vitro cell culture system for viral propagation, no "gold standard" assay has yet been developed to detect HEV infection in domestic pigs. 1E4, a monoclonal antibody (mAb) specific for the C-terminal 268 amino acids of HEV genotype 4 ORF2 capsid protein (sORF2-C), was generated and conjugated to horseradish peroxidase (HRP) for use in a blocking ELISA (bELISA). Optimal sORF2-C coating antigen concentration (8 μg/ml), HRP-1E4 dilution (1:1000), and test pig serum dilution (1:20) were determined using a checkerboard titration test. A cut-off value of 16.9% was chosen to differentiate between positive vs. negative sera after mean percent inhibition (PI) testing of 230 negative pig sera. Compared with the indirect ELISA (iELISA), western blot, and a commercial ELISA kit for detecting anti-HEV antibodies in human sera, the bELISA showed no statistical differences and statistically high coincidence of 93.23%, 92%, and 95% with the other tests, respectively. A blocking ELISA (bELISA) for detecting anti-HEV antibodies in pig serum samples was developed with high sensitivity and high specificity comparable to that of the indirect ELISA. The bELISA results exhibited high agreement with iELISA, western blot, and a commercial ELISA kit designed to detect human anti-HEV antibodies. Therefore, bELISA should serve as an ideal method for large-scale serological investigation of anti-HEV antibodies in domestic pigs.

  7. Improved quantification of a commercial enzyme-linked immunosorbent assay kit for measuring anti-MDA5 antibody.

    PubMed

    Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka

    2018-04-09

    To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.

  8. [An indirect ELISA using Legionella pneumophila recombinant MOMP protein and its application in serological diagnosis].

    PubMed

    Wang, Tao; Zhang, Caixia; Cao, Xiuqin; Yang, Zhiwei

    2013-12-01

    To express and purify the recombinant major outer membrane protein (MOMP) of Legionella pneumophila (Lp) as diagnostic antigen, and explore its practical value in the serological diagnosis of Lp infection. The recombinant plasmid pET-momp was transformed into the E.coli BL21 competent cells. The recombinant MOMP was induced to express, and then analyzed by SDS-PAGE electrophoresis, purified by affinity chromatography. We screened and obtained 58 positive blood serum and 32 negative blood serum using the DRG (Germany, IgG/IgM/IgA) Lp kit. The blood serum samples were detected for IgG, IgM, IgA antibody levels by indirect ELISA that we had established with the purified MOMP as the coating antigen, as well as by R&D (USA, IgG/IgM/IgA) Lp kit. Then using the receiver operating characteristic (ROC) curve, we compared these two methods in the sensitivity, specificity and consistency of the test results, for evaluating the application value of the indirect ELISA of recombinant MOMP. The approximately 45 000 recombinant MOMP was successfully expressed and purified. Compared with the indirect ELISA we established with the R&D Lp kit for detecting Lp antibody IgG, IgM and IgA in blood serum, the sensitivity of the indirect ELISA of recombinant MOMP to IgG was 90.9%, the specificity was 91.7%, the Kappa value was 0.784 (P < 0.05), and the area under the ROC curve was 0.913; the sensitivity to IgM was 91.4% and the specificity was 90.6%, the Kappa value was 0.809 (P < 0.05), and the area under the ROC curve was 0.910; the sensitivity to IgA was 92.1% and the specificity was 88.9%, the Kappa value was 0.793(P < 0.05), and the area under the ROC curve was 0.905. The recombinant MOMP was successfully induced to express and purified. The indirect ELISA we established with the recombinant MOMP protein as a diagnostic antigen showed good specificity, sensitivity and consistency, which laid a foundation for the development of serological diagnosis kit of Legionnaires' disease.

  9. Optimization and Validation of ELISA for Pre-Clinical Trials of Influenza Vaccine.

    PubMed

    Mitic, K; Muhandes, L; Minic, R; Petrusic, V; Zivkovic, I

    2016-01-01

    Testing of every new vaccine involves investigation of its immunogenicity, which is based on monitoring its ability to induce specific antibodies in animals. The fastest and most sensitive method used for this purpose is enzyme-linked immunosorbent assay (ELISA). However, commercial ELISA kits with whole influenza virus antigens are not available on the market, and it is therefore essential to establish an adequate assay for testing influenza virusspecific antibodies. We developed ELISA with whole influenza virus strains for the season 2011/2012 as antigens and validated it by checking its specificity, accuracy, linearity, range, precision, and sensitivity. The results show that we developed high-quality ELISA that can be used to test immunogenicity of newly produced seasonal or pandemic vaccines in mice. The pre-existence of validated ELISA enables shortening the time from the process of vaccine production to its use in patients, which is particularly important in the case of a pandemic.

  10. Detection of cow milk adulteration in yak milk by ELISA.

    PubMed

    Ren, Q R; Zhang, H; Guo, H Y; Jiang, L; Tian, M; Ren, F Z

    2014-10-01

    In the current study, a simple, sensitive, and specific ELISA assay using a high-affinity anti-bovine β-casein monoclonal antibody was developed for the rapid detection of cow milk in adulterated yak milk. The developed ELISA was highly specific and could be applied to detect bovine β-casein (10-8,000 μg/mL) and cow milk (1:1,300 to 1:2 dilution) in yak milk. Cross-reactivity was <1% when tested against yak milk. The linear range of adulterant concentration was 1 to 80% (vol/vol) and the minimum detection limit was 1% (vol/vol) cow milk in yak milk. Different treatments, including heating, acidification, and rennet addition, did not interfere with the assay. Moreover, the results were highly reproducible (coefficient of variation <10%) and we detected no significant differences between known and estimated values. Therefore, this assay is appropriate for the routine analysis of yak milk adulterated with cow milk. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Recombinant glycoprotein G analog for determination of specific immunoglobulins to herpes simplex virus type 2 by ELISA.

    PubMed

    Korshun, Ludmila; Vudmaska, Mariya; Moysa, Larissa; Kovtonjuk, Galina; Mikhalap, Svetlana; Ganova, Larissa; Spivak, Nikolay

    2013-12-01

    In order to the detection of type-specific IgG to herpes simplex virus type 2 (HSV-2) in human serum or plasma the recombinant analog of HSV-2 glycoprotein G (gG2) was created. To construct an expression vector the DNA fragment with a sequence identical to immunodominant regions of HSV-2 gG2 was cloned into modified vector pET28a containing of the glutation-S-transferase sequence (pET28-GST). Escherichia coli BL21 (DE3) were transformed with the recombinant plasmid. The target protein was expressed mainly in soluble form. Chromatographic purification of soluble GST-gG2 protein was performed taking into account the features of its primary structure that are 6His-tag and GST-tag. To determine the affinity constant of the specific IgG to GST-gG2 we used the method proposed by Friguet et al. (1985). The affinity constants were within the range of 10(7)-10(8)M(-1) proving their high-affinity. The purified recombinant HSV-2 antigen was used to design a diagnostic ELISA kit, which was evaluated with referent controls and standard panels of sera containing and/or not containing anti-HSV-2 IgG. Comparative evaluation of this kit and the commercially available "HSV-Type 2 IgG-ELISA" (NovaTec, Dietzenbach, Germany) kit was performed. There was no significant difference (P>0.05). It allows to use developed ELISA kit for clinical diagnosis of HSV-2 infection. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. Comparison of microscopy, ELISA, and real-time PCR for detection of Giardia intestinalis in human stool specimens

    PubMed

    Beyhan, Yunus Emre; Taş Cengiz, Zeynep

    2017-08-23

    Background/aim: This study included patients who had digestive system complaints between August 2015 and October 2015. The research was designed to compare conventional microscopy with an antigen detection ELISA kit and the TaqMan-based real-time PCR (RT-PCR) technique for detection of Giardia intestinalis in human stool specimens. Materials and methods: Samples were concentrated by formalin-ether sedimentation technique and microscopic examinations were carried out on wet mount slides. A commercially available ELISA kit (Giardia CELISA, Cellabs, Brookvale, Australia) was used for immunoassay. DNA was extracted from fecal samples of about 200 mg using the QIAamp Fast DNA Stool Mini Kit (QIAGEN, Hilden, Germany) and the LightCycler Nano system (Roche Diagnostics, Mannheim, Germany) was used for the TaqMan-based RT-PCR assay. Results: A total of 94 stool samples, 38 of them diagnosed positive (40.4%) and 56 of them diagnosed negative by microscopy, were selected for evaluation by antigen detection and molecular assays. The prevalence of G. intestinalis infection was found as 46.8% (n: 44) and 79.8% (n: 75) by ELISA and RT-PCR, respectively. RT-PCR revealed by far the highest positivity rate compared to the other two methods. The difference between these methods was found to be statistically significant (P < 0.05). In comparison to PCR, the sensitivity and specificity of microscopy and ELISA were 50.7% and 100% and 53.3% and 79%, respectively. Conclusion: RT-PCR seems to be much more sensitive and beneficial for rapid and accurate diagnosis of G. intestinalis in human stools.

  13. Improved detection of Bovine Viral Diarrhea Virus in Bovine lymphoid cell lines using PrimeFlow RNA assay

    USDA-ARS?s Scientific Manuscript database

    Bovine viral diarrhea virus (BVDV) infections, whether as acute, persistent or contributing to co-infections, result in significant losses for cattle producers. BVDV can be identified by real-time PCR and ELISA, detection and quantification of viral infection at the single cell level is extremely di...

  14. Improved detection of bovine viral diarrhea virus in bovine lymphoid cell lines using PrimeFlow RNA assay

    USDA-ARS?s Scientific Manuscript database

    Bovine viral diarrhea virus (BVDV) infections, whether as acute, persistent or contributing to co-infections, result in significant losses for cattle producers. BVDV can be identified by real-time PCR and ELISA, detection and quantification of viral infection at the single cell level is extremely di...

  15. Serodiagnosis of bovine leptospirosis by IgG-enzyme-linked immunosorbent assay and latex agglutination test.

    PubMed

    Senthilkumar, T M A; Subathra, M; Ramadass, P; Ramaswamy, V

    2010-02-01

    The efficacy of a recombinant leptospiral outer membrane protein LipL41 as an antigen for conducting IgG-Enzyme linked immunosorbent assay (ELISA) and latex agglutination test (LAT) for serodiagnosis of bovine leptospirosis was evaluated. The recombinant LipL41 antigen developed and used for detecting the antibodies was specific in detection of the pathogenic serovars of Leptospira, as the expression of the LipL41 antigen is restricted only to pathogenic leptospires. A total of 430 bovine serum samples were subjected to IgG-ELISA and LAT, and the sensitivity and specificity were assessed in comparison with microscopic agglutination test (MAT). The sensitivity and specificity of IgG-ELISA and LAT were 86.84% and 93.16%, and 95.42% and 98.33% respectively. Both the tests are found to be sensitive, specific and concurred with the standard MAT. The study concluded that the rLipL41 protein could be used as a potential diagnostic antigen in different assay formats for bovine leptospirosis.

  16. [Extraction method suitable for detection of unheated crustaceans including cephalothorax by ELISA].

    PubMed

    Shibahara, Yusuke; Yamada, Itta; Uesaka, Yoshihiko; Uneo, Noriko; Abe, Akihisa; Ohashi, Eiji; Shiomi, Kazuo

    2009-08-01

    When unheated whole samples of crustaceans (shrimp, prawn and crab) were analyzed with our ELISA kit (FA test EIA-Crustacean 'Nissui') using anti-tropomyosin antibodies, a remarkable reduction in reactivity was recognized. This reduction in activity was found to be due to the digestion of tropomyosin during the extraction process by proteases contained in cephalothorax. To avoid the digestion of tropomyosin by proteases, we developed an extraction method (heating method) suitable for the detection of tropomyosin in unheated crustaceans including cephalothorax. Experiments with unheated whole samples of various species of crustaceans confirmed that the heating method greatly improved the low reactivity in the standard method; the heating method gave extraction efficiencies of as high as 93-107%. Various processed crustaceans with cephalothorax, such as dry products (unheated or weakly heated products) and pickles in soy sauce (unheated products), that showed low reactivity with the standard method were confirmed to give superior results with the heating method. These results indicated that the developed heating method is suitable for detecting unheated crustaceans with cephalothorax by means of the ELISA kit.

  17. Analysis of the major epitope of the alpha2 chain of bovine type I collagen in children with bovine gelatin allergy.

    PubMed

    Hori, Hisae; Hattori, Shunji; Inouye, Sakae; Kimura, Akinori; Irie, Shinkichi; Miyazawa, Hiroshi; Sakaguchi, Masahiro

    2002-10-01

    Anaphylaxis to measles, mumps, and rubella vaccines has been reported. It has been found that most of these reactions to live vaccines are caused by type I allergy with the bovine gelatin present in the vaccines as an allergen. Gelatin mainly includes denatured type I collagen, which consists of alpha1 and alpha2 chains. We previously reported that allergic reactions to gelatin are caused by the type I collagen alpha2 (alpha2[I]) chain. To aid in the development of gelatin that has little or no allergenicity in human subjects, we investigated epitopes of bovine alpha2(I) chain with use of IgE in gelatin-sensitive children. Serum samples were collected from 15 patients who had systemic allergic reactions to vaccines and high levels of specific IgE to bovine gelatin. Eleven overlapping recombinant proteins that cover bovine alpha2(I) were prepared with a bacterial expression vector. We examined IgE reactivity to these recombinant proteins by means of ELISA. Fifteen peptides covering a major reactive recombinant protein were synthesized. The IgE-reacting epitope was identified by means of IgE-ELISA inhibition with these synthetic peptides and pooled serum from the patients. We found that of the 15 patients, 13 showed IgE reactivity to a recombinant protein (no. 3) spanning the central region of the collagenous domain ((418)Gly-(662)Pro). Furthermore, all 13 patients showed IgE reactivity to the 4-kd recombinant protein (no. 3a) spanning the region from (461)Pro to (500)Glu. In IgE-ELISA inhibition we found that a minimum IgE epitope of gelatin allergen was composed of the 10-amino-acid sequence (485)Ile-Pro-Gly-Glu-Phe-Gly-Leu-Pro-Gly-Pro(494). This sequence is not observed in the human type I collagen alpha1 and alpha2 chains, nor is it found in the bovine type I collagen alpha1 chain. We found that Ile-Pro-Gly-Glu-Phe-Gly-Leu-Pro-Gly-Pro is a major IgE epitope of the alpha2 chain of bovine type I collagen in patients with gelatin allergy. The degree of anaphylaxis

  18. Validation of an ELISA Synthetic Cannabinoids Urine Assay.

    PubMed

    Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A

    2015-10-01

    Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, coadministered drugs, over-the-counter medications, or structurally similar compounds, and 19 of 73 individual synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.

  19. Validation of an ELISA Synthetic Cannabinoids Urine Assay

    PubMed Central

    Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.

    2015-01-01

    Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046

  20. Specific detection and quantitation of bovine IgG in bioreactor derived mouse mAb preparations.

    PubMed

    Gall-Debreceni, Anna; Lazar, Jozsef; Kadas, Janos; Balogh, Attila; Ferenczi, Annamaria; Sos, Endre; Takacs, Laszlo; Kurucz, Istvan

    2016-11-01

    Monoclonal antibody and recombinant protein production benefits greatly from bovine serum as an additive. The caveat is that bovine serum IgG, co-purifies with mAbs and IgG Fc-containing fusion proteins and it presents a contaminant in the end products. In order to analytically validate the products, species specific reagents are needed that react with bovine IgG exclusively. Our attempts to find such commercially available reagents failed. Here, we report the production of species specific mAbs which recognize bovine IgG even in the presence of excess amount of mouse IgG. We present five mAbs: Bsi4028, Bsi4032, Bsi4033, Bsi4034 and Bsi4035 suitable to determine the presence of bovine IgG contamination via ELISA or immunoblotting in bioreactor derived mouse mAb preparations. To quantitate bovine IgG content we developed sensitive sandwich ELISAs capable to detect bovine IgG contaminant in the ng/ml (~10 -11 M/l) range. Finally, we show that bovine IgG is efficiently removed from bioreactor produced mouse mAb preparation via affinity depletion columns prepared with Bsi4028, Bsi4032, Bsi4033, Bsi4034, Bsi4035 mAbs. Copyright © 2016. Published by Elsevier B.V.

  1. Peptidomic Approach to Developing ELISAs for the Determination of Bovine and Porcine Processed Animal Proteins in Feed for Farmed Animals.

    PubMed

    Huet, Anne-Catherine; Charlier, Caroline; Deckers, Elise; Marbaix, Hélène; Raes, Martine; Mauro, Sergio; Delahaut, Philippe; Gillard, Nathalie

    2016-11-30

    The European Commission (EC) wants to reintroduce nonruminant processed animal proteins (PAPs) safely into the feed chain. This would involve replacing the current ban in feed with a species-to-species ban which, in the case of nonruminants, would only prohibit feeding them with proteins from the same species. To enforce such a provision, there is an urgent need for species-specific methods for detecting PAPs from several species in animal feed and in PAPs from other species. Currently, optical microscopy and the polymerase chain reaction are the officially accepted methods, but they have limitations, and alternative methods are needed. We have developed immunoassays using antibodies raised against targets which are not influenced by high temperature and pressure. These targets were identified in a previous study based on an experimental approach. One optimized competitive ELISA detects bovine PAPs at 2% in plant-derived feed. The detection capability demonstrated on blind samples shows a good correlation with mass spectrometry results.

  2. Multi-allergen Quantitation and the Impact of Thermal Treatment in Industry-Processed Baked Goods by ELISA and Liquid Chromatography-Tandem Mass Spectrometry.

    PubMed

    Parker, Christine H; Khuda, Sefat E; Pereira, Marion; Ross, Mark M; Fu, Tong-Jen; Fan, Xuebin; Wu, Yan; Williams, Kristina M; DeVries, Jonathan; Pulvermacher, Brian; Bedford, Binaifer; Zhang, Xi; Jackson, Lauren S

    2015-12-16

    Undeclared food allergens account for 30-40% of food recalls in the United States. Compliance with ingredient labeling regulations and the implementation of effective manufacturing allergen control plans require the use of reliable methods for allergen detection and quantitation in complex food products. The objectives of this work were to (1) produce industry-processed model foods incurred with egg, milk, and peanut allergens, (2) compare analytical method performance for allergen quantitation in thermally processed bakery products, and (3) determine the effects of thermal treatment on allergen detection. Control and allergen-incurred cereal bars and muffins were formulated in a pilot-scale industry processing facility. Quantitation of egg, milk, and peanut in incurred baked goods was compared at various processing stages using commercial enzyme-linked immunosorbent assay (ELISA) kits and a novel multi-allergen liquid chromatography (LC)-tandem mass spectrometry (MS/MS) multiple-reaction monitoring (MRM) method. Thermal processing was determined to negatively affect the recovery and quantitation of egg, milk, and peanut to different extents depending on the allergen, matrix, and analytical test method. The Morinaga ELISA and LC-MS/MS quantitative methods reported the highest recovery across all monitored allergens, whereas the ELISA Systems, Neogen BioKits, Neogen Veratox, and R-Biopharm ELISA Kits underperformed in the determination of allergen content of industry-processed bakery products.

  3. Vitamin B12 absorption judged by measurement of holotranscobalamin, active vitamin B12: evaluation of a commercially available EIA kit.

    PubMed

    Greibe, Eva; Nexo, Ebba

    2011-11-01

    Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.

  4. The feasibility of harmonizing gluten ELISA measurements.

    PubMed

    Rzychon, Malgorzata; Brohée, Marcel; Cordeiro, Fernando; Haraszi, Reka; Ulberth, Franz; O'Connor, Gavin

    2017-11-01

    Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  5. A novel monoclonal antibody-based enzyme-linked immunosorbent assay to determine luteinizing hormone in bovine plasma.

    PubMed

    Borromeo, V; Berrini, A; De Grandi, F; Cremonesi, F; Fiandanese, N; Pocar, P; Secchi, C

    2014-07-01

    The development of a novel enzyme-linked immunosorbent assay (ELISA) for determining luteinizing hormone (LH) in bovine plasma is described. Anti-bovine LH (bLH) monoclonal antibodies (mAbs) were produced and characterized. One mAb recognizing the bLH β subunit was used for immunoaffinity purification of substantial amounts of biologically active bLH from pituitary glands. The purified bLH in combination with 2 anti-bLH β subunit mAbs was used to develop a sandwich ELISA, which satisfied all the criteria required to investigate LH secretory patterns in the bovine species. The ELISA standard curve was linear over the range 0.05 to 2.5 ng/mL, and the assay proved suitable for measuring bLH in plasma without any prior treatment of samples. Cross-reactivity and recovery tests confirmed the specificity of the method. The intra- and inter-assay coefficients of variation ranged between 3.41% and 9.40%, and 9.29% and 15.84%, respectively. The analytical specificity of the method was validated in vivo by provocative tests for LH in heifers, using the LH releasing peptide gonadotropin-releasing hormone. In conclusion, the adoption of mAbs for this ELISA for coating the wells and labeling, combined with the easy one-step production of reference bLH, ensures long-term continuity in large-scale measurements of LH in the bovine species. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. [Establishment of enzyme-linked immunosorbent assay (ELISA) for measuring human urinary uromodulin and application of the method in patients with IgA nephropathy].

    PubMed

    Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong

    2012-04-18

    To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.

  7. Seroprevalence of Fasciola gigantica infection in bovines using cysteine proteinase dot enzyme-linked immunosorbent assay

    PubMed Central

    Kumar, Niranjan; Varghese, Anju; Solanki, J. B.

    2017-01-01

    Aim: The objective of the present study was to know the seroprevalence status of Fasciola gigantica infection in cattle and buffaloes using cysteine proteinase (CP) antigen in dot enzyme-linked immunosorbent assay (ELISA) format under field conditions. Materials and Methods: As per the standard protocol, the sera were collected from the blood of 112 cattle and 38 buffaloes of coastal areas of Navsari district, South Gujarat, India. The indirect ELISA was performed on the strip of nitrocellulose paper blotted with 1 µl of CP antigen, to detect F. gigantica seropositive animals. Results: The native CP of F. gigantica revealed a single visible band on 10% sodium dodecyl sulfate-polyacrylamide gel electrophoresis. There was no any noted cross-reaction between the selected antigen and sera of Gastrothylax crumenifer-infected animals in ELISA. Out of 150 screened bovines, the sera of 47 (31.33%) were found to be reactive in dot-ELISA, with a prevalence rate of 31.25% and 31.58% in cattle and buffaloes, respectively. The seropositive bovines with heavy, moderate, and light level of infection were 44.68%, 34.04%, and 21.28%, respectively (p<0.05 between heavy and light; p>0.05 between moderate and heavy or light). The share of F. gigantica seropositive and negative animals was 31% and 69%, respectively. The optical density at 450 nm of pooled sera of seropositive bovines with heavy, moderate, and light reactivity in plate-ELISA was significantly higher with field or reference ­negative sera. Conclusion: The CP-based dot-ELISA can be useful for field veterinarians for quick and timely isolation of the animals requiring urgent flukicide therapy. PMID:29184364

  8. Evaluating an indirect rMPSP enzyme-linked immunosorbent assay for the detection of bovine Theileria infection in China.

    PubMed

    Zhao, Shuaiyang; Liu, Junlong; Zhao, Hongxi; Li, Youquan; Xie, Junren; Liu, Aihong; Hassan, Muhammad-Adeel; Yin, Hong; Guan, Guiquan; Luo, Jianxun

    2017-02-01

    Bovine theileriosis, a tick-borne protozoan disease caused by Theileria annulata, Theileria orientalis and Theileria sinensis, is widespread in China and is a serious economic problem for the Chinese livestock industry. In this study, recombinant major piroplasma surface proteins (MPSP) of T. annulata, T. orientalis and T. sinensis based on MPSP genes were expressed in Escherichia coli BL21(DE3). The immunogenicity and specificity of the three purified recombinant MPSP proteins were evaluated with the reference positive sera of T. annulata, T. orientalis, T. sinensis, Babesia bovis, B abesia bigemina, Babesia major, Babesia motasi, Theileria luwenshuni, Theileria uilenbergi and Anaplasma ovis using an enzyme-linked immunosorbent assay (ELISA) or western blotting. The results showed that all three of the rMPSP proteins had a strong reaction with the sera from cattle infected with T. annulata, T. orientalis and T. sinensis via western blotting but not with other piroplasma and Anaplasma species. Then, the rMPSP protein of T. sinensis was used to develop an iELISA for detecting the three Theileria species infections. The specificity and sensitivity were 95.7 and 95.5 %, respectively, with a threshold of 28.8 % of the specific mean antibody rate (AbR). Finally, 2473 field-collected bovine sera, from 42 prefectures of 17 provinces in China, were tested using the ELISA to evaluate the prevalence of bovine theileriosis, and the average positive rate was 43.6 %. The developed iELISA could be a suitable tool to detect the three bovine Theileria species, and the data also provided important information regarding the current prevalence of bovine theileriosis in China.

  9. Serological diagnosis of bovine brucellosis using B. melitensis strain B115.

    PubMed

    Corrente, Marialaura; Desario, Costantina; Parisi, Antonio; Grandolfo, Erika; Scaltrito, Domenico; Vesco, Gesualdo; Colao, Valeriana; Buonavoglia, Domenico

    2015-12-01

    Bovine brucellosis is diagnosed by official tests, such as Rose Bengal plate test (RBPT) and Complement Fixation test (CFT). Both tests detect antibodies directed against the lipolysaccharide (LPS) of Brucella cell wall. Despite their good sensitivity, those tests do not discriminate between true positive and false positive serological reactions (FPSR), the latter being generated by animals infected with other Gram negative microorganisms that share components of Brucella LPS. In this study, an antigenic extract from whole Brucella melitensis B115 strain was used to set up an ELISA assay for the serological diagnosis of bovine brucellosis. A total of 148 serum samples from five different groups of animals were tested: Group A: 28 samples from two calves experimentally infected with Yersinia enterocolitica O:9; Group B: 30 samples from bovines infected with Brucella abortus; Group C: 50 samples from brucellosis-free herds; Group D: 20 samples RBPT positive and CFT negative; Group E: 20 samples both RBPT and CFT positive. Group D and Group E serum samples were from brucellosis-free herds. Positive reactions were detected only by RBPT and CFT in calves immunized with Y. enterocolitica O:9. Sera from Group B animals tested positive also in the ELISA assay, whereas sera from the remaining groups were all negative. The results obtained encourage the use of the ELISA assay to implement the serological diagnosis of brucellosis. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Cross-reactivity of antibodies with phenolic compounds in pistachios during quantification of ochratoxin A by commercial enzyme-linked immunosorbent assay kits.

    PubMed

    Lee, Hyun Jung; Meldrum, Alexander D; Rivera, Nicholas; Ryu, Dojin

    2014-10-01

    Ochratoxin A (OTA), a nephrotoxic mycotoxin, naturally occurs in wide range of agricultural commodities. Typical screening of OTA involves various enzyme-linked immunosorbent assay (ELISA) methods. Pistachio (Pistacia vera L.) is a rich source of phenolic compounds that may result in a false positive due to structural similarities to OTA. The present study investigated the cross-reactivity profiles of phenolic compounds using two commercial ELISA test kits. High-performance liquid chromatography was used to confirm the concentration of OTA in the pistachio samples and compared with the results obtained from ELISA. When the degree of interaction and 50 % inhibitory concentration of phenolic compounds were determined, the cross-reactivity showed a pattern similar to that observed with the commercial ELSIA kits, although quantitatively different. In addition, the degree of interaction increased with the increasing concentration of phenolic compounds. The ELISA value had stronger correlations with the content of total phenolic compound, gallic acid, and catechin (R(2) = 0.757, 0.732, and 0.729, respectively) compared with epicatechin (R(2) = 0.590). These results suggest that phenolic compounds in pistachio skins may cross-react with the OTA antibody and lead to a false positive or to an overestimation of OTA concentration in ELISA-based tests.

  11. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    PubMed

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  12. Serological diagnosis of bovine neosporosis: a Bayesian evaluation of two antibody ELISA tests for in vivo diagnosis in purchased and abortion cattle.

    PubMed

    Roelandt, S; Van der Stede, Y; Czaplicki, G; Van Loo, H; Van Driessche, E; Dewulf, J; Hooyberghs, J; Faes, C

    2015-06-06

    Currently, there are no perfect reference tests for the in vivo detection of Neospora caninum infection. Two commercial N caninum ELISA tests are currently used in Belgium for bovine sera (TEST A and TEST B). The goal of this study is to evaluate these tests used at their current cut-offs, with a no gold standard approach, for the test purpose of (1) demonstration of freedom of infection at purchase and (2) diagnosis in aborting cattle. Sera of two study populations, Abortion population (n=196) and Purchase population (n=514), were selected and tested with both ELISA's. Test results were entered in a Bayesian model with informative priors on population prevalences only (Scenario 1). As sensitivity analysis, two more models were used: one with informative priors on test diagnostic accuracy (Scenario 2) and one with all priors uninformative (Scenario 3). The accuracy parameters were estimated from the first model: diagnostic sensitivity (Test A: 93.54 per cent-Test B: 86.99 per cent) and specificity (Test A: 90.22 per cent-Test B: 90.15 per cent) were high and comparable (Bayesian P values >0.05). Based on predictive values in the two study populations, both tests were fit for purpose, despite an expected false negative fraction of ±0.5 per cent in the Purchase population and ±5 per cent in the Abortion population. In addition, a false positive fraction of ±3 per cent in the overall Purchase population and ±4 per cent in the overall Abortion population was found. British Veterinary Association.

  13. A Laboratory Exercise to Illustrate Increased Salivary Cortisol in Response to Three Stressful Conditions Using Competitive ELISA

    ERIC Educational Resources Information Center

    Haussmann, Mark F.; Vleck, Carol M; Farrar, Eugenia S.

    2007-01-01

    Perceived stress activates the hypothalamus-pituitary-adrenal axis, resulting in the release of glucocorticoids into the systemic circulation. Glucocorticoids cause the elevation of blood glucose, providing the necessary energy for the organism to cope with stress. Here, we outline a laboratory exercise that uses a competitive ELISA kit to…

  14. Detection of tetracosactide in plasma by enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Martin, Laurent; Chaabo, Ayman; Lasne, Françoise

    2015-06-01

    As a synthetic analogue of adrenocorticotropic hormone (ACTH), tetracosactide is prohibited in sport by the World Anti-Doping Agency (WADA). An enzyme-linked immunosorbent assay (ELISA) method is proposed for detection of this drug in plasma. Since its structure corresponds to the 24 N-terminal of the 39 amino acids of the natural endogenous peptide ACTH, tetracosactide can be detected with a commercial ELISA kit for ACTH that uses antibodies, the epitopes of which are located in the 1-24 part of ACTH. However, an essential condition for detection specificity is the preliminary total clearance of endogenous ACTH in the plasma samples. This is achieved by a preparative step based on cation-exchange chromatography before ELISA. The method is specific and sensitive (LOD: 30 pg/mL) and may be used as a screening analysis in anti-doping control. The pre-analytical conditions are shown to be of the upmost importance and recommendations for blood collection (EDTA tubes), sample transport (4 °C) and plasma sample storage (-20 °C) are presented. Copyright © 2014 John Wiley & Sons, Ltd.

  15. Identification of Novel Immunogenic Proteins from Mycoplasma bovis and Establishment of an Indirect ELISA Based on Recombinant E1 Beta Subunit of the Pyruvate Dehydrogenase Complex

    PubMed Central

    Wei, Kai; Zhang, Haiyan; Zhang, Yuewei; Xu, Jian; Jiang, Fei; Liu, Xu; Xu, Wei; Wu, Wenxue

    2014-01-01

    The pathogen Mycoplasma bovis (M. bovis) is a major cause of respiratory disease, mastitis, and arthritis in cattle. Screening the key immunogenic proteins and updating rapid diagnostic techniques are necessary to the prevention and control of M. bovis infection. In this study, 19 highly immunogenic proteins from M. bovis strain PD were identified using 2-dimensional gel electrophoresis, immunoblotting and MALDI-TOF/TOF MS. Of these 19 proteins, pyruvate dehydrogenase E1 component beta subunit (PDHB) showed excellent immune reactivity and repeatability. PDHB was found to be conserved in different M. bovis isolates, as indicated by Western blot analysis. On the basis of these results, a rPDHB-based indirect ELISA (iELISA) was established for the detection of serum antibodies using prokaryotically expressed recombinant PDHB protein as the coating antigen. The specificity analysis result showed that rPDHB-based iELISA did not react with other pathogens assessed in our study except M. agalactiae (which infects sheep and goats). Moreover, 358 serum samples from several disease-affected cattle feedlots were tested using this iELISA system and a commercial kit, which gave positive rates of 50.8% and 39.9%, respectively. The estimated Kappa agreement coefficient between the two methods was 0.783. Notably, 39 positive serum samples that had been missed by the commercial kit were all found to be positive by Western blot analysis. The detection rate of rPDHB-based iELISA was significantly higher than that of the commercial kit at a serum dilution ratio of 1∶5120 to 1∶10,240 (P<0.05). Taken together, these results provide important information regarding the novel immunogenic proteins of M. bovis. The established rPDHB-based iELISA may be suitable for use as a new method of antibody detection in M. bovis. PMID:24520369

  16. Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.

    PubMed

    Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C

    2016-01-01

    This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.

  17. Development of a sandwich ELISA for the quantification of enterovirus 71.

    PubMed

    Ma, Shujun; Mao, Qunying; Liang, Zhenglun; Zhang, Cuijuan; Yang, Wenxing; Sun, Zhe; Zhang, Haijiang; Shen, Xinliang; Bi, Shengli; Sun, Le

    2014-05-01

    Since 2008, enterovirus 71 (EV71) has been responsible for high-mortality seasonal epidemics of hand, foot and mouth disease in China. Currently many groups in the world are in the process of developing EV71 vaccines to combat this deadly disease. We have developed three EV71-specific monoclonal antibodies, and in this study we report the establishment of a fast and cost-effective sandwich ELISA kit for measurement of virus concentration in EV71 vaccines using a pair of mouse anti-EV71 monoclonal antibodies. The system is specific for EV71 virus, with no cross-reactivity to coxsackievirus A16, H1N1, rabies, and hepatitis A. Using a reference EV71 vaccine standard, the sensitivity of the assay kit was determined to be 0.82 U/ml, with a linear range between 3.75 and 120 U/ml.

  18. Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.

    PubMed

    Sparding, Nadja; Slotved, Hans-Christian; Nicolaisen, Gert M; Giese, Steen B; Elmlund, Jón; Steenhard, Nina R

    2014-01-01

    After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin) with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments) for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.

  19. Techni-kits and Techni-kit Building Systems

    NASA Technical Reports Server (NTRS)

    Callender, E. D.; Hartsough, C.; Morris, R. V.; Yamamoto, Y.

    1985-01-01

    Techni-kits consists of theories, methods, standards and computer based tools that assist in design of information-intensive systems. Techni-kit "building system" is techni-kit that builds techni-kits.

  20. Prevalence of bovine brucellosis in organized dairy farms, using milk ELISA, in quetta city, balochistan, pakistan.

    PubMed

    Shafee, Muhammad; Rabbani, Masood; Sheikh, Ali Ahmad; Ahmad, Mansoor Din; Razzaq, Abdul

    2011-01-24

    A total of 200 milk samples from cattle (n = 86) and buffalo (n = 114) were evaluated using milk ring test (MRT) and indirect enzyme-linked immunosorbent assay (i-ELISA). The overall prevalence was found to be 3% and 8.5% in cattle and buffaloes using MRT and i-ELISA, respectively. The prevalence was 4.6% and 1.7% in cattle and buffalo using MRT, respectively, while i-ELISA exhibited 20% and 0% in cattle and buffalo, respectively. The prevalence was higher in government dairy farm, compared to privately owned dairy farm. This paper points out an alarming situation in the target area with respect to the public health significance.

  1. Prevalence of Bovine Brucellosis in Organized Dairy Farms, Using Milk ELISA, in Quetta City, Balochistan, Pakistan

    PubMed Central

    Shafee, Muhammad; Rabbani, Masood; Sheikh, Ali Ahmad; Ahmad, Mansoor din; Razzaq, Abdul

    2011-01-01

    A total of 200 milk samples from cattle (n = 86) and buffalo (n = 114) were evaluated using milk ring test (MRT) and indirect enzyme-linked immunosorbent assay (i-ELISA). The overall prevalence was found to be 3% and 8.5% in cattle and buffaloes using MRT and i-ELISA, respectively. The prevalence was 4.6% and 1.7% in cattle and buffalo using MRT, respectively, while i-ELISA exhibited 20% and 0% in cattle and buffalo, respectively. The prevalence was higher in government dairy farm, compared to privately owned dairy farm. This paper points out an alarming situation in the target area with respect to the public health significance. PMID:21331157

  2. The cost-effectiveness of predonation screening for transfusion transmissible infections using rapid test kits in a hospital-based blood transfusion centre.

    PubMed

    Dosunmu, Adedoyin Owolabi; Akinbami, Akinsegun Abduljaleel; Ismail, Ayobami Kamal; Olaiya, Modupe Adebimpe; Uche, Ebele Ifeyinwa; Aile, Igbinoba Kingsley

    2017-01-01

    Blood transfusion practice emphasises safety, efficacy and appropriate use. These require cost-effective programme management. This study focused on the cost of screening for transfusion transmissible infections (TTI). This was a 1 year (2016) analysis of screening in a hospital-based transfusion centre. The cost of screening all blood donors by ELISA was compared to the cost of serial screening starting from rapid kit, taking into account, the estimated cost of blood bags prevented from discard after ELISA screening (attributable cost). The cost of voluntary donor drive plus cost of ELISA screening was compared with the present cost of screening. A total of 5591 donors were screened for HIV, hepatitis B and C using the rapid kit, 291 donors were deferred (5.2%). A total of 5300 units were further screened by ELISA. A total of 435 blood units (8.2%) were discarded due to TTI positivity. TTI positivity rate was 12.98%. Only 2.36% were voluntary donors and among these 9.1% were TTI positive. The attributable cost of serial screening was 55,653.5 USD while that of screening by ELISA only was 55,910 USD. The attributable cost of rapid screening for only hepatitis B and then ELISA was 53,313.9 USD taking into consideration that 187 blood units would be prevented from undue discard. This analysis demonstrated that with proper donor selection, rapid screening for hepatitis B virus only before ELISA screening is more cost-effective. This will also reduce the waiting time for donors and counselling if HIV positive.

  3. Bovine herpesvirus-1 (BHV-1), bovine leukemia virus (BLV) and bovine viral diarrhea virus (BVDV) infections in Algerian dromedary camels (Camelus dromaderius).

    PubMed

    Saidi, Radhwane; Bessas, Amina; Bitam, Idir; Ergün, Yaşar; Ataseven, Veysel Soydal

    2018-03-01

    This study was performed to investigate the presence of bovine herpesvirus-1 (BHV-1), bovine leukemia virus (BLV) and bovine viral diarrhea virus (BVDV) infections in dromedary camels (Camelus dromaderius) kept in mixed herds with sheep and goats in Algeria, since the prevalence of BHV-1, BVDV, and BLV infections among dromedary camels in Algeria is unknown. Totally, 111 camel sera were collected from two provinces (Laghouat and Ghardaia) in Algeria. The sera were analyzed for BHV-1 specific antibodies, BVDV specific antibodies and BVDV antigen using the ELISA, and BLV nucleic acid using PCR. The seropositivity rate was 9.0% for BVDV-specific antibody, although 41.4% of camels tested were positive for BVDV antigen. Moreover, there was no evidence of BHV-1 and BLV infections. The results indicated that camels might represent an important source for BVDV infection in all ruminants, including cattle, sheep, and goats bred in mixed herds in Algeria, since they had a higher BVDV prevalence rates. Therefore, the prevention and control measures for BVDV infection should put in place in camel populations to limit the spread of BVDV infection to ruminant populations in Algeria.

  4. Detection of Bovine IgG Isotypes in a PPA-ELISA for Johne's Disease Diagnosis in Infected Herds

    PubMed Central

    Fernández, Bárbara; Gilardoni, Liliana Rosa; Jolly, Ana; Colavecchia, Silvia Beatriz; Paolicchi, Fernando Alberto; Mundo, Silvia Leonor

    2012-01-01

    Johne's Disease or Paratuberculosis is a chronic granulomatous enteritis disease affecting ruminants. Detection of subclinically infected animals is difficult, hampering the control of this disease. The aim of this work was to evaluate the performance of detection of IgG isotypes in a PPA-ELISA to improve the recognition of cattle naturally infected with Map in different stages. A total of 108 animals from Tuberculosis-free herds were grouped as follows: exposed (n = 30), subclinically infected (n = 26), clinically infected (n = 14), and healthy controls (n = 38). Receiver-operating characteristic (ROC) curves of isotypes/PPA-ELISAs were constructed and areas under the curves were compared to evaluate the performance of each test. Our study demonstrated that the conventional PPA-ELISA (detecting IgG) is the best to identify clinically infected animals with high sensitivity (92.9%) and specificity (100%). Meanwhile, IgG2/PPA-ELISA improved the number of subclinically infected cattle detected as compared with conventional IgG/PPA-ELISA (53.8 versus 23.1%). In addition, it had the maximum sensitivity (65.0%, taking into account all Map-infected cattle). In conclusion, the combination of IgG and IgG2/PPA-ELISAs may improve the identification of Map-infected cattle in different stages of disease. The usefulness of IgG2 detection in serological tests for Johne's Disease diagnosis should be further evaluated. PMID:22792511

  5. Detection of Bovine IgG Isotypes in a PPA-ELISA for Johne's Disease Diagnosis in Infected Herds.

    PubMed

    Fernández, Bárbara; Gilardoni, Liliana Rosa; Jolly, Ana; Colavecchia, Silvia Beatriz; Paolicchi, Fernando Alberto; Mundo, Silvia Leonor

    2012-01-01

    Johne's Disease or Paratuberculosis is a chronic granulomatous enteritis disease affecting ruminants. Detection of subclinically infected animals is difficult, hampering the control of this disease. The aim of this work was to evaluate the performance of detection of IgG isotypes in a PPA-ELISA to improve the recognition of cattle naturally infected with Map in different stages. A total of 108 animals from Tuberculosis-free herds were grouped as follows: exposed (n = 30), subclinically infected (n = 26), clinically infected (n = 14), and healthy controls (n = 38). Receiver-operating characteristic (ROC) curves of isotypes/PPA-ELISAs were constructed and areas under the curves were compared to evaluate the performance of each test. Our study demonstrated that the conventional PPA-ELISA (detecting IgG) is the best to identify clinically infected animals with high sensitivity (92.9%) and specificity (100%). Meanwhile, IgG2/PPA-ELISA improved the number of subclinically infected cattle detected as compared with conventional IgG/PPA-ELISA (53.8 versus 23.1%). In addition, it had the maximum sensitivity (65.0%, taking into account all Map-infected cattle). In conclusion, the combination of IgG and IgG2/PPA-ELISAs may improve the identification of Map-infected cattle in different stages of disease. The usefulness of IgG2 detection in serological tests for Johne's Disease diagnosis should be further evaluated.

  6. Direct determination of neonicotinoid insecticides in an analytically challenging crop such as Chinese chives using selective ELISAs.

    PubMed

    Watanabe, Eiki; Miyake, Shiro

    2018-06-05

    Easy-to-use commercial kit-based enzyme-linked immunosorbent assays (ELISAs) have been used to detect neonicotinoid dinotefuran, clothianidin and imidacloprid in Chinese chives, which are considered a troublesome matrix for chromatographic techniques. Based on their high water solubility, water was used as an extractant. Matrix interference could be avoided substantially just diluting sample extracts. Average recoveries of insecticides from spiked samples were 85-113%, with relative standard deviation of <15%. The concentrations of insecticides detected from the spiked samples with the proposed ELISA methods correlated well with those by the reference high-performance liquid chromatography (HPLC) method. The residues analyzed by the ELISA methods were consistently 1.24 times that found by the HPLC method, attributable to loss of analyte during sample clean-up for HPLC analyses. It was revealed that the ELISA methods can be applied easily to pesticide residue analysis in troublesome matrix such as Chinese chives.

  7. A commercial ELISA detects high levels of human H5 antibody but cross-reacts with influenza A antibodies.

    PubMed

    Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D

    2008-10-01

    Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.

  8. Estimation of the diagnostic performance of two ELISAs to detect PCV2 antibodies in pig sera using a Bayesian method.

    PubMed

    Fablet, C; Rose, N; Bernard, C; Messager, I; Piel, Y; Grasland, B

    2017-11-01

    This study was designed to assess the diagnostic characteristics of two PCV2 ELISAs without a gold standard. Four hundred and sixty-five serum samples from finishing pigs (25 herds) not vaccinated against PCV2 were used. Samples were tested by two ELISAs: an in-house ELISA (I-ELISA) and the commercial SERELISA ® PCV2 Ab Mono Blocking kit (S-ELISA). A ROC curve was used to assess the S-ELISA's optimal threshold by taking the I-ELISA as a reference and using the cut-off previously determined by comparison to an cccmonolayer assay (IPMA). This led to an S-ELISA result ≥170 being considered as positive. The sensitivity (Se) and specificity (Sp) of each ELISA were then estimated without a gold standard using a Bayesian approach. The mean Se and Sp values of the I-ELISA were slightly higher than those of the S-ELISA (mean Se I-ELISA=0.90 vs. mean Se S-ELISA=0.86; mean Sp I-ELISA=0.92 vs. mean Sp S-ELISA=0.85). However, the 95% credibility intervals (CI95%) overlapped (Se I-ELISA CI95%=0.85-0.95 vs. Se S-ELISA CI95%=0.82-0.90; Sp I-ELISA CI95%=0.82-0.98 vs. Sp S-ELISA CI95%=0.75-0.94). Both ELISAs appeared to be valuable tools for detecting PCV2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Production of Bioactive Recombinant Bovine Chymosin in Tobacco Plants

    PubMed Central

    Wei, Zheng-Yi; Zhang, Yu-Ying; Wang, Yun-Peng; Fan, Ming-Xia; Zhong, Xiao-Fang; Xu, Nuo; Lin, Feng; Xing, Shao-Chen

    2016-01-01

    Chymosin (also known as rennin) plays an essential role in the coagulation of milk in the cheese industry. Chymosin is traditionally extracted from the rumen of calves and is of high cost. Here, we present an alternative method to producing bovine chymosin from transgenic tobacco plants. The CYM gene, which encodes a preprochymosin from bovine, was introduced into the tobacco nuclear genome under control of the viral 35S cauliflower mosaic promoter. The integration and transcription of the foreign gene were confirmed with Southern blotting and reverse transcription PCR (RT-PCR) analyses, respectively. Immunoblotting analyses were performed to demonstrate expression of chymosin, and the expression level was quantified by enzyme-linked immunosorbent assay (ELISA). The results indicated recombinant bovine chymosin was successfully expressed at an average level of 83.5 ng/g fresh weight, which is 0.52% of the total soluble protein. The tobacco-derived chymosin exhibited similar native milk coagulation bioactivity as the commercial product extracted from bovine rumen. PMID:27136529

  10. Blood collected on filter paper for wildlife serology: detecting antibodies to Neospora caninum, West Nile virus, and five bovine viruses in reindeer.

    PubMed

    Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J

    2014-04-01

    We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.

  11. VPAC1 Targeted 64Cu-TP3805 kit preparation and its evaluation.

    PubMed

    Tripathi, Sushil K; Kumar, Pardeep; Trabulsi, Edouard J; Kim, Sung; McCue, Peter A; Intenzo, Charles; Berger, Adam; Gomella, Leonard; Thakur, Mathew L

    2017-08-01

    Previously, our laboratory has shown that 64 Cu-TP3805 can specifically target VPAC1 receptors and be used for positron emission tomography (PET) imaging of breast (BC) and prostate cancer (PC) in humans. Present work is aimed at the formulation of a freeze-dried diaminedithiol-peptide (N 2 S 2 -TP3805) kit and it's evaluation for the preparation of 64 Cu labeled TP3805. Parameters such as pH, temperature and incubation time were examined that influenced the radiolabeling efficiency and stability of the product. Kits were prepared under different conditions and radiolabeling efficiency of TP3805 kit was evaluated for a range of pH3.5-8.5, after addition of 64 Cu in 30μl, 0.1M HCl. Incubation temperature (37-90°C) and time (30-120min.) were also investigated. Kits were stored at -10°C and their long term stability was determined as a function of their radiolabeling efficiency. Further, stability of 64 Cu-TP3805 complex was evaluated in presence of fetal bovine serum and bovine serum albumin by using SDS polyacrylamide gel electrophoresis. Kits were then used for PET imaging of BC and PC following eIND (101550) and institutional approvals. Specificity of 64 Cu-TP3805 for VPAC1 was examined with digital autoradiography (DAR) of prostate tissues obtained after prostatectomy, benign prostatic hyperplasia (BPH) tissue, and benign and malignant lymph nodes. Results were compared with corresponding tissue histology. Radiolabeling efficiency was ≥95% at final pH ~7.2 when incubated at 50°C for 90min. Kits were stable up to 18months when stored at -10°C, and 64 Cu-TP3805 complex exhibited excellent stability for up to 4h at room temperature. 64 Cu-TP3805 complex did not show any transchelation even after 2h incubation at 37°C in 10% FBS as well as in BSA as determined by SDS PAGE analysis. DAR identified ≥95% of malignant lesions 11 new PC lesions, 20 high grade prostatic intraepithelial neoplasia, 2/2 ejaculatory ducts and 5/5 urethra verumontanum not previously

  12. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Chemical kits and First aid kits must conform to... 10 kg. (b) Chemical kits and First aid kits are excepted from the specification packaging...

  13. Development of a serodiagnostic IgM-ELISA for tick-borne encephalitis virus using subviral particles with strep-tag.

    PubMed

    Nakayasu, Miki; Hirano, Minato; Muto, Memi; Kobayashi, Shintaro; Kariwa, Hiroaki; Yoshii, Kentaro

    2018-06-23

    Tick-borne encephalitis virus (TBEV) is a zoonotic agent causing severe encephalitis in humans. IgM antibody detection is useful for the serological diagnosis of TBEV infection, because IgM has high specificity for each flavivirus and indicates a recent infection. Commercial IgM-ELISA kits are somewhat expensive and difficulties in their sensitivity have been suggested due to their format and formalin-inactivated antigens. Therefore, the development of an inexpensive IgM-ELISA with high specificity and sensitivity is needed. In this study, a μ-capture ELISA was developed to detect TBEV-specific IgM antibodies using subviral particles (SPs) with strep-tag (strep-SP-IgM-ELISA). The results of our strep-SP-IgM-ELISA were highly correlated with diagnoses made by the neutralization test (sensitivity: 94.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in patients who could not be diagnosed with the neutralization test. Besides, 51 of 52 positive samples by a commercial IgM-ELISA were also diagnosed as positive by our strep-SP-IgM-ELISA (98.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in all samples that were inconclusive based on the commercial IgM-ELISA. Our strep-SP-IgM-ELISA will be useful for diagnoses in TBE-endemic areas. Copyright © 2018 Elsevier GmbH. All rights reserved.

  14. Simultaneous detection of bovine and porcine DNA in pharmaceutical gelatin capsules by duplex PCR assay for Halal authentication.

    PubMed

    Nikzad, Jafar; Shahhosseini, Soraya; Tabarzad, Maryam; Nafissi-Varcheh, Nastaran; Torshabi, Maryam

    2017-02-14

    In the pharmaceutical industry, hard- and soft-shelled capsules are typically made from gelatin, commonly derived from bovine and porcine sources. To ensure that pharmaceutical products comply with halal regulations in Muslim countries (no porcine products allowed), development of a valid, reliable, quick, and most importantly, cost-effective tests are of utmost importance. We developed a species-specific duplex polymerase chain reaction (PCR) assay targeting 149 bp porcine and 271 bp bovine mitochondrial DNA (mtDNA) to simultaneously detect both porcine and bovine DNA (in one reaction at the same time) in gelatin. Some additional simplex PCR tests (targeting 126 bp bovine and 212 bp porcine mtDNA) and real-time PCR using a commercially available kit (for identification of porcine DNA) were used to verify the selectivity and sensitivity of our duplex PCR. After optimization of DNA extraction and PCR methods, hard/soft pharmaceutical gelatin capsules (containing drug) were tested for the presence of porcine and/or bovine DNA. Duplex PCR detected the presence of as little as 0.1% porcine DNA, which was more accurate than the commercially available kit. Of all gelatin capsules tested (n = 24), 50% contained porcine DNA (pure porcine gelatin alone or in combination with bovine gelatin). Duplex PCR presents an easy-to-follow, quick, low-cost and reliable method to simultaneously detect porcine and bovine DNAs (>100 bp) in minute amounts in highly processed gelatin-containing pharmaceutical products (with a 0.1% sensitivity for porcine DNA) which may be used for halal authentication. Simultaneous detection of porcine and bovine DNA in gelatin capsules by duplex PCR.

  15. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Chemical kits and first aid kits. 173.161 Section... Class 7 § 173.161 Chemical kits and first aid kits. (a) Applicability. Chemical kits and first aid kits... assigned to the chemical kit and first aid kit as a whole must be the most stringent packing group assigned...

  16. Performance of two commercial ELISAs for detecting IgA anti-human and anti-guinea pig tissue transglutaminase antibodies.

    PubMed

    Abrantes-Lemos, Clarice Pires; Nakhle, Maria Cristina; Damiao, Aderson Omar Mourao Cintra; Sipahi, Aytan Miranda; Carrilho, Flair José; Cancado, Eduardo Luiz R

    2010-01-01

    Sensitivity and specificity of anti-human tissue transglutaminase antibodies (anti-htTGA) seem to be superior to those of anti-tissue transglutaminase of guinea pig (anti-gptTGA) for screening patients with celiac disease (CD), but there are still controversies. The aim of this study was to evaluate the performance of two INOVA ELISA kits to detect IgA anti-htTGA and anti-gptTGA in patients with and without CD. The study groups were comprised of 49 anti-endomysial antibody (EMA)-positive untreated-CD, and 123 controls (EMA-negative treated CD, EMA-negative chronic diarrhea, autoimmune hepatitis, inflammatory bowel disease and healthy people). The agreement between the two ELISAs was statistically significant in all study groups and there was no significant difference between them (92.7% agreement; kappa = 0.70; kappa p = 0.001; McNemar p = 1). All patients with serum reactivity of more than 100 units had histologic diagnosis of CD. In seven of 10 patients with treated-CD who had control biopsies, villous atrophy was still present in four who tested positive by both kits. Two of three celiacs with histologic remission tested positive for both anti-tTGA. the anti-gptTGA and anti-htTGA determination were equally efficient in identifying patients with untreated-CD with high titers of EMA. Whatever the anti-tTGA ELISA used, the reactivity above 100 units was always related to active CD diagnosed by histologic alterations in intestinal biopsies. The anti-tTGA reactivity by both kits was not only similar in determining histologic activity in the follow-up of CD after a gluten free diet, but also in identifying positive sera from the control groups, regardless if CD has been confirmed by duodenal biopsies.

  17. A PiggyBac mediated approach for lactoferricin gene transfer in bovine mammary epithelial stem cells for management of bovine mastitis.

    PubMed

    Sharma, Neelesh; Huynh, Do Luong; Kim, Sung Woo; Ghosh, Mrinmoy; Sodhi, Simrinder Singh; Singh, Amit Kumar; Kim, Nam Eun; Lee, Sung Jin; Hussain, Kafil; Oh, Sung Jong; Jeong, Dong Kee

    2017-11-28

    The antibacterial and anti-inflammatory properties of lactoferricin have been ascribed to its ability to sequester essential iron. The objective of the study was to clone bovine lactoferricin ( LFcinB ) gene into PiggyBac Transposon vector, expression study in the bovine mammary epithelial stem cells (bMESCs) and also to determine the antimicrobial property of recombinant LFcinB against bovine mastitis-causing organisms. The PiggyBac-LFcinB was transfected into bMESCs by electroporation and a three fold of LFcinB secretion was observed in the transfected bMESCs medium by ELISA assay. Furthermore, the assessment of antimicrobial activity against mastitis causing pathogens Staphylococcus aureus and Escherichia coli demonstrated convincing evidence to prove strong antibacterial activity of LFcinB with 14.0±1.0 mm and 18.0±1.5 mm zone of inhibition against both organisms, respectively. The present study provides the convincing evidence to suggest the potential of PiggyBac transposon system to transfer antibacterial peptide into bMESCs or cow mammary gland and also pave the way to use bovine mammary gland as the bioreactors. Simultaneously, it also suggest toward commercial utilization of LFcinB bioreactor system in pharmaceutical industry.

  18. A PiggyBac mediated approach for lactoferricin gene transfer in bovine mammary epithelial stem cells for management of bovine mastitis

    PubMed Central

    Sharma, Neelesh; Huynh, Do Luong; Kim, Sung Woo; Ghosh, Mrinmoy; Sodhi, Simrinder Singh; Singh, Amit Kumar; Kim, Nam Eun; Lee, Sung Jin; Hussain, Kafil; Oh, Sung Jong; Jeong, Dong Kee

    2017-01-01

    The antibacterial and anti-inflammatory properties of lactoferricin have been ascribed to its ability to sequester essential iron. The objective of the study was to clone bovine lactoferricin (LFcinB) gene into PiggyBac Transposon vector, expression study in the bovine mammary epithelial stem cells (bMESCs) and also to determine the antimicrobial property of recombinant LFcinB against bovine mastitis-causing organisms. The PiggyBac-LFcinB was transfected into bMESCs by electroporation and a three fold of LFcinB secretion was observed in the transfected bMESCs medium by ELISA assay. Furthermore, the assessment of antimicrobial activity against mastitis causing pathogens Staphylococcus aureus and Escherichia coli demonstrated convincing evidence to prove strong antibacterial activity of LFcinB with 14.0±1.0 mm and 18.0±1.5 mm zone of inhibition against both organisms, respectively. The present study provides the convincing evidence to suggest the potential of PiggyBac transposon system to transfer antibacterial peptide into bMESCs or cow mammary gland and also pave the way to use bovine mammary gland as the bioreactors. Simultaneously, it also suggest toward commercial utilization of LFcinB bioreactor system in pharmaceutical industry. PMID:29262639

  19. Elisa Miller | NREL

    Science.gov Websites

    Elisa Miller Photo of Elisa Miller Elisa Link-Miller Researcher III-Chemistry Elisa.Miller@nrel.gov | 303-384-6777 Dr. Elisa Miller-Link studies the surface of semiconductors that are applicable for , and other nanocrystalline films. Elisa came to NREL in 2013 as an NREL Director's Fellowship recipient

  20. Performance Tested Method multiple laboratory validation study of ELISA-based assays for the detection of peanuts in food.

    PubMed

    Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah

    2005-01-01

    Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.

  1. A monoclonal antibody based elisa for quantitation of human leukaemia inhibitory factor.

    PubMed

    Taupin, J L; Gualde, N; Moreau, J F

    1997-02-01

    The authors report on the development of a new sandwich enzyme-linked immunoabsorbent assay (ELISA) for the quantitation of the human cytokine leukaemia inhibitory factor/human interleukin for DA cells (LIF/HILDA) with high accuracy and sensitivity (23 pg/ml), in less than 5 h and in various biological fluids. The antibodies used in this assay were raised against recombinant glycosylated LIF expressed in vivo following inoculation of recombinant vaccinia viruses, and screened with the biologically active cytokine in a flow cytometry assay using cells expressing a membrane-bound form of LIF. Furthermore, this home-made assay was compared with two commercially available ELISA kits. The results led to the conclusion that these three assays are far from being equivalent between each other, in terms of sensitivity towards non-glycosylated vs glycosylated LIF. Two major parameters must be incriminated: the glycosylation status of the LIF molecule used as the calibrator, and the binding characteristics of the monoclonal antibodies used to set up these assays toward LIF derived from Escherichia coli or from eukaryotic cells. This points out the importance of these parameters for the design of ELISAs meant for the quantitation of glycosylated cytokines in biological fluids.

  2. An ELISA Lab-on-a-Chip (ELISA-LOC).

    PubMed

    Rasooly, Avraham; Bruck, Hugh A; Kostov, Yordan

    2013-01-01

    Laminated object manufacturing (LOM) technology using polymer sheets is an easy and affordable method for rapid prototyping of Lab-on-a-Chip (LOC) systems. It has recently been used to fabricate a miniature 96 sample ELISA lab-on-a-chip (ELISA-LOC) by integrating the washing step directly into an ELISA plate. LOM has been shown to be capable of creating complex 3D microfluidics through the assembly of a stack of polymer sheets with features generated by laser micromachining and by bonding the sheets together with adhesive. A six layer ELISA-LOC was fabricated with an acrylic (poly(methyl methacrylate) (PMMA)) core and five polycarbonate layers micromachined by a CO(2) laser with simple microfluidic features including a miniature 96-well sample plate. Immunological assays can be carried out in several configurations (1 × 96 wells, 2 × 48 wells, or 4 × 24 wells). The system includes three main functional elements: (1) a reagent loading fluidics module, (2) an assay and detection wells plate, and (3) a reagent removal fluidics module. The ELISA-LOC system combines several biosensing elements: (1) carbon nanotube (CNT) technology to enhance primary antibody immobilization, (2) sensitive ECL (electrochemiluminescence) detection, and (3) a charge-coupled device (CCD) detector for measuring the light signal generated by ECL. Using a sandwich ELISA assay, the system detected Staphylococcal enterotoxin B (SEB) at concentrations as low as 0.1 ng/ml, a detection level similar to that reported for conventional ELISA. ELISA-LOC can be operated by a syringe and does not require power for operation. This simple point-of-care (POC) system is useful for carrying out various immunological assays and other complex medical assays without the laboratory required for conventional ELISA, and therefore may be more useful for global healthcare delivery.

  3. Detection of Human Epididymis Protein 4 (HE4) in Human Serum Samples Using a Specific Monoclonal Antibody-Based Sandwich Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan

    2016-09-01

    The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.

  4. IgE reactivity to alpha1 and alpha2 chains of bovine type 1 collagen in children with bovine gelatin allergy.

    PubMed

    Sakaguchi, M; Hori, H; Hattori, S; Irie, S; Imai, A; Yanagida, M; Miyazawa, H; Toda, M; Inouye, S

    1999-09-01

    Anaphylactic reactions to measles, mumps, and rubella vaccines, including gelatin as a stabilizer, have been reported. It had been found that most of these reactions to live vaccines are caused by the bovine gelatin included in these vaccines. Gelatin mainly includes denatured type I collagen, which consists of alpha1 and alpha2 chains. The current study was designed to investigate the IgE reactivity to alpha1 and alpha2 chains of bovine type I collagen in gelatin-sensitive children. Serum samples were taken from 10 children who had anaphylaxis to the vaccines and high levels of specific IgE to bovine gelatin. Bovine type I collagen was isolated from bovine skin and then separated to alpha1 and alpha2 chains by column chromatography. IgE reactivity to denatured type I collagen and its alpha1 and alpha2 chains was analyzed by immunoblotting, ELISA, and histamine release from the mast cells passive sensitized with IgE antibodies in pooled serum of the children. All children had specific IgE to bovine type I collagen. Furthermore, IgE antibodies in their sera reacted with the alpha;2 chain but not with the alpha1 chain. Similarly, the mast cells sensitized with pooled sera in the children showed alpha2 chain-specific histamine release but not alpha1 chain-specific histamine release. In gelatin allergy denatured bovine type I collagen is a major allergen and IgE-binding sites exist in the alpha2 chain of type I collagen.

  5. Development and Evaluation of a Novel ELISA for Detection of Antibodies against HTLV-I Using Chimeric Peptides.

    PubMed

    Mosadeghi, Parvin; Heydari-Zarnagh, Hafez

    2018-04-01

    We aimed to develope a peptide-based indirect ELISA to detect antibodies against Human T-lymphotropic virus type I (HTLV-I). Two chimeric peptides (CP-1 and CP-2) were designed using linear immunodominant epitopes of gp-46-I, and gp21-I proteins, according to the sequence from Uniprot database. These peptides were studied initially in the ELISA using infected sera. The most promising peptideCP-1, was used to develop a peptide ELISA for detection of HTLV-I infected sera. The optimal conditions for CP-1ELISA were: the optimum coating buffer was 100mM NaHCO3, pH 9.6; coating peptide concentration was 10 µg/mL; the optimal blocking buffer was5% fetal bovine serum (FBS); the secondary antibody concentration was 1:2000; and serum dilution was 1:20. 20serum samples from HTLV-I infected patients were evaluated by ELISA developed. CP-1 showed high antigenicity while lacking any cross-reactivity with normal human sera. The results of evaluations indicated that in comparison with commercial ELISA, CP-1 ELISA showed good sensitivity and specificity. With further validation, CP-1as described in the present study could be introduced as novel reliable and cost-effective candidates for the high-specific screening of HTLV-I/-II infections in endemic regions.

  6. Quantitation of bovine immunoglobulin isotypes and allotypes using monoclonal antibodies.

    PubMed

    Williams, D J; Newson, J; Naessens, J

    1990-03-01

    A panel of 10 monoclonal antibodies specific for bovine immunoglobulins M, A, G1, G2 and light chains were produced and enzyme-linked immunosorbent assays developed to measure Ig levels in body fluids and culture supernatants using this panel of MAbs. An inhibition ELISA was accurate and sensitive for MAbs of high affinity, detecting levels as low as 10 ng ml-1 of IgM using a high-affinity MAb, IL-A50 (dissociation constant = 1.3 X 10(-11) M). For MAbs of lower affinity (KD of less than 0.25 X 10(-9) M) a sandwich ELISA was more sensitive, detecting 0.1-1.0 microgram ml-1 Ig, provided a conjugate of an anti-light chain MAb was used. Using these ELISA techniques, four pairs of MAbs specific for bovine IgM, IgA, IgG1 and IgG2 respectively, were screened on sera from over 100 cattle of different breeds to determine whether any detected a polymorphic epitope. MAbs IL-A30, IL-A60, IL-A66, IL-A71, IL-A72, IL-A73 and IL-A74 were shown to recognise monomorphic determinants on their respective heavy chains. In contrast, the epitope recognised on the mu-heavy chain by MAb IL-A50, which had previously been shown to be polymorphic, was found to be allelic and inherited under the control of a single gene, probably Cu.

  7. Influence of baking time and matrix effects on the detection of milk allergens in cookie model food system by ELISA.

    PubMed

    Monaci, Linda; Brohée, Marcel; Tregoat, Virginie; van Hengel, Arjon

    2011-07-15

    Milk allergens are common allergens occurring in foods, therefore raising concern in allergic consumers. Enzyme-linked immunosorbent assay (ELISA) is, to date, the method of choice for the detection of food allergens by the food industry although, the performance of ELISA might be compromised when severe food processing techniques are applied to allergen-containing foods. In this paper we investigated the influence of baking time on the detection of milk allergens by using commercial ELISA kits. Baked cookies were chosen as a model food system and experiments were set up to study the impact of spiking a matrix food either before, or after the baking process. Results revealed clear analytical differences between both spiking methods, which stress the importance of choosing appropriate spiking methodologies for method validation purposes. Finally, since the narrow dynamic range of quantification of ELISA implies that dilution of samples is required, the impact of sample dilution on the quantitative results was investigated. All parameters investigated were shown to impact milk allergen detection by means of ELISA. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Comparison of Protein Immunoprecipitation-Multiple Reaction Monitoring with ELISA for Assay of Biomarker Candidates in Plasma

    PubMed Central

    2013-01-01

    Quantitative analysis of protein biomarkers in plasma is typically done by ELISA, but this method is limited by the availability of high-quality antibodies. An alternative approach is protein immunoprecipitation combined with multiple reaction monitoring mass spectrometry (IP-MRM). We compared IP-MRM to ELISA for the analysis of six colon cancer biomarker candidates (metalloproteinase inhibitor 1 (TIMP1), cartilage oligomeric matrix protein (COMP), thrombospondin-2 (THBS2), endoglin (ENG), mesothelin (MSLN) and matrix metalloproteinase-9 (MMP9)) in plasma from colon cancer patients and noncancer controls. Proteins were analyzed by multiplex immunoprecipitation from plasma with the ELISA capture antibodies, further purified by SDS-PAGE, digested and analyzed by stable isotope dilution MRM. IP-MRM provided linear responses (r = 0.978–0.995) between 10 and 640 ng/mL for the target proteins spiked into a “mock plasma” matrix consisting of 60 mg/mL bovine serum albumin. Measurement variation (coefficient of variation at the limit of detection) for IP-MRM assays ranged from 2.3 to 19%, which was similar to variation for ELISAs of the same samples. IP-MRM and ELISA measurements for all target proteins except ENG were highly correlated (r = 0.67–0.97). IP-MRM with high-quality capture antibodies thus provides an effective alternative method to ELISA for protein quantitation in biological fluids. PMID:24224610

  9. Proteomic characterisation of bovine and avian purified protein derivatives and identification of specific antigens for serodiagnosis of bovine tuberculosis.

    PubMed

    Infantes-Lorenzo, José Antonio; Moreno, Inmaculada; Risalde, María de Los Ángeles; Roy, Álvaro; Villar, Margarita; Romero, Beatriz; Ibarrola, Nieves; de la Fuente, José; Puentes, Eugenia; de Juan, Lucía; Gortázar, Christian; Bezos, Javier; Domínguez, Lucas; Domínguez, Mercedes

    2017-01-01

    Bovine purified protein derivative (bPPD) and avian purified protein derivative (aPPD) are widely used for bovine tuberculosis diagnosis. However, little is known about their qualitative and quantitative characteristics, which makes their standardisation difficult. In addition, bPPD can give false-positive tuberculosis results because of sequence homology between Mycobacterium bovis ( M. bovis ) and M. avium proteins. Thus, the objective of this study was to carry out a proteomic characterisation of bPPD, aPPD and an immunopurified subcomplex from bPPD called P22 in order to identify proteins contributing to cross-reactivity among these three products in tuberculosis diagnosis. Trypsin digests of bPPD, aPPD and P22 were analysed by nanoscale liquid chromatography-electrospray ionization tandem mass spectrometry. Mice were immunised with bPPD or aPPD, and their serum was tested by indirect ELISA for reactivity against these preparations as well as against P22. A total of 456 proteins were identified in bPPD, 1019 in aPPD and 118 in P22; 146 of these proteins were shared by bPPD and aPPD, and 43 were present in all three preparations. Candidate proteins that may cause cross-reactivity between bPPD and aPPD were identified based on protein abundance and antigenic propensity. Serum reactivity experiments indicated that P22 may provide greater specificity than bPPD with similar sensitivity for ELISA-type detection of antibodies against M. tuberculosis complex. The subpreparation from bPPD called P22 may be an alternative to bPPD for serodiagnosis of bovine tuberculosis, since it shares fewer proteins with aPPD than bPPD does, reducing risk of cross-reactivity with anti- M. avium antibodies.

  10. 2004 National Atrazine Occurrence Monitoring Program using the Abraxis ELISA method.

    PubMed

    Graziano, Nicole; McGuire, Michael J; Roberson, Alan; Adams, Craig; Jiang, Hua; Blute, Nicole

    2006-02-15

    The goal of this project was to gain a better understanding of atrazine occurrence in the United States by surveying drinking water utilities' sources and finished water for atrazine on a weekly basis for seven months. Atrazine is a contaminant of interest because the United States Environmental Protection Agency (USEPA) has found short-term atrazine exposure above the drinking water maximum contaminant level (MCL) to potentially cause heart, lung, and kidney congestion, low blood pressure, muscle spasms, weight loss, and damage to the adrenal glands. Long-term exposure to atrazine concentrations above the drinking water MCL has been linked to weight loss, cardiovascular damage, retinal and muscle degeneration, and cancer. This survey effort improved upon previously conducted atrazine surveys through intensive, high frequency sampling (participating plants sampled their raw and finished water on a weekly basis for approximately seven months). Such an intensive effort allowed the authors to gain a better understanding of short-term atrazine occurrence and its variability in drinking water sources. This information can benefit the drinking water industry by facilitating (1) better atrazine occurrence management (i.e., awareness when plants may be more susceptible to atrazine), (2) more efficient atrazine control (e.g., effective treatment alternatives and more effective response to atrazine occurrence), and (3) treatment cost reduction (e.g., efficient atrazine control can result in substantial cost savings). Forty-seven drinking watertreatment plants located primarily in the Midwestern United States participated in the survey and sampled their raw and finished water on a weekly basis from March through October. Samples were analyzed using the Abraxis enzyme-linked immunosorbent assay (ELISA) test kit. Confirmation samples for quality assurance/quality control (QA/QC) purposes were analyzed using solid-phase extraction (SPE) followed by gas chromatography mass

  11. An international collaborative study to determine the prevalence of contagious caprine pleuropneumonia by monoclonal antibody-based cELISA.

    PubMed

    Peyraud, Armelle; Poumarat, François; Tardy, Florence; Manso-Silván, Lucía; Hamroev, Karomatullo; Tilloev, Tillo; Amirbekov, Mullojon; Tounkara, Karim; Bodjo, Charles; Wesonga, Hezron; Nkando, Isabel Gacheri; Jenberie, Shiferaw; Yami, Martha; Cardinale, Eric; Meenowa, Deodass; Jaumally, Mahmad Reshad; Yaqub, Tahir; Shabbir, Muhammad Zubair; Mukhtar, Nadia; Halimi, Mohibullah; Ziay, Ghulam Mohammad; Schauwers, Willy; Noori, Hafizullah; Rajabi, Ali Madad; Ostrowski, Stéphane; Thiaucourt, François

    2014-02-24

    Few serological tests are available for detecting antibodies against Mycoplasma capricolum subsp. capripneumoniae, the causal agent of contagious caprine pleuropneumonia (CCPP). The complement fixation test, the test prescribed for international trade purposes, uses a crude antigen that cross-reacts with all the other mycoplasma species of the "mycoides cluster" frequently infecting goat herds. The lack of a more specific test has been a real obstacle to the evaluation of the prevalence and economic impact of CCPP worldwide. A new competitive ELISA kit for CCPP, based on a previous blocking ELISA, was formatted at CIRAD and used to evaluate the prevalence of CCPP in some regions of Kenya, Ethiopia, Mauritius, Tajikistan and Pakistan in an international collaborative study. The strict specificity of the test was confirmed in CCPP-free goat herds exposed to other mycoplasma species of the "mycoides cluster". Prevalence studies were performed across the enzootic range of the disease in Africa and Asia. Seroprevalence was estimated at 14.6% in the Afar region of Ethiopia, whereas all the herds presented for CCPP vaccination in Kenya tested positive (individual seroprevalence varied from 6 to 90% within each herd). In Mauritius, where CCPP emerged in 2009, nine of 62 herds tested positive. In Central Asia, where the disease was confirmed only recently, no positive animals were detected in the Wakhan District of Afghanistan or across the border in neighboring areas of Tajikistan, whereas seroprevalence varied between 2.7% and 44.2% in the other districts investigated and in northern Pakistan. The test was also used to monitor seroconversion in vaccinated animals. This newly formatted CCPP cELISA kit has retained the high specificity of the original kit. It can therefore be used to evaluate the prevalence of CCPP in countries or regions without vaccination programs. It could also be used to monitor the efficacy of vaccination campaigns as high-quality vaccines induce high

  12. An international collaborative study to determine the prevalence of contagious caprine pleuropneumonia by monoclonal antibody-based cELISA

    PubMed Central

    2014-01-01

    Background Few serological tests are available for detecting antibodies against Mycoplasma capricolum subsp. capripneumoniae, the causal agent of contagious caprine pleuropneumonia (CCPP). The complement fixation test, the test prescribed for international trade purposes, uses a crude antigen that cross-reacts with all the other mycoplasma species of the “mycoides cluster” frequently infecting goat herds. The lack of a more specific test has been a real obstacle to the evaluation of the prevalence and economic impact of CCPP worldwide. A new competitive ELISA kit for CCPP, based on a previous blocking ELISA, was formatted at CIRAD and used to evaluate the prevalence of CCPP in some regions of Kenya, Ethiopia, Mauritius, Tajikistan and Pakistan in an international collaborative study. Results The strict specificity of the test was confirmed in CCPP-free goat herds exposed to other mycoplasma species of the “mycoides cluster”. Prevalence studies were performed across the enzootic range of the disease in Africa and Asia. Seroprevalence was estimated at 14.6% in the Afar region of Ethiopia, whereas all the herds presented for CCPP vaccination in Kenya tested positive (individual seroprevalence varied from 6 to 90% within each herd). In Mauritius, where CCPP emerged in 2009, nine of 62 herds tested positive. In Central Asia, where the disease was confirmed only recently, no positive animals were detected in the Wakhan District of Afghanistan or across the border in neighboring areas of Tajikistan, whereas seroprevalence varied between 2.7% and 44.2% in the other districts investigated and in northern Pakistan. The test was also used to monitor seroconversion in vaccinated animals. Conclusions This newly formatted CCPP cELISA kit has retained the high specificity of the original kit. It can therefore be used to evaluate the prevalence of CCPP in countries or regions without vaccination programs. It could also be used to monitor the efficacy of vaccination

  13. ELISA assays and alcohol: increasing carbon chain length can interfere with detection of cytokines

    PubMed Central

    von Maltzan, Kristine; Pruett, Stephen B.

    2010-01-01

    Enzyme-linked immunosorbent assays (ELISA) are frequently used in studies on cytokine production in response to treatment of cell cultures or laboratory animals. When an ELISA assay is performed on cell culture supernatants, samples often contain the treatment agents. The purpose of the present study was to determine if some of the agents evaluated might inhibit cytokine detection by interfering with the ELISA, leaving the question of whether cytokine production was inhibited unanswered. Mouse and human cytokine ELISA kits from BD Biosciences were used according to the manufacturer’s instructions. Cytokine proteins were subjected to one to five carbon alcohols at 86.8 mM (methanol, ethanol, 1-propanol, 2-propanol, n-butanol, and n-pentanol). After treating cell cultures with alcohols of different carbon chain lengths, we found that some of the alcohols interfered with measurement of some cytokines by ELISA, thus making their effects on cytokine production by cells in culture unclear. Increasing carbon chain length of straight chain alcohols positively correlated with their ability to inhibit detection of TNF-α and IL-10, but not with the detection of IL-6, IL-8, and IL-12. To avoid misinterpretation of treatment effects, ELISA assays should be tested with the reference protein and the treatment agent first, before testing biological samples. These results along with other recent results we obtained using circular dichroism indicate that alcohols with 2 or more carbons can directly alter protein conformation enough to disrupt binding in an ELISA (shown in the present study) or to inhibit ligand induced conformational changes (results not shown). Such direct effects have not been given enough consideration as a mechanism of ethanol action in the immune system. PMID:20843633

  14. SP-A binding sites on bovine alveolar macrophages.

    PubMed

    Plaga, S; Plattner, H; Schlepper-Schaefer, J

    1998-11-25

    Surfactant protein A (SP-A) binding to bovine alveolar macrophages was examined in order to characterize SP-A binding proteins on the cell surface and to isolate putative receptors from these cells that could be obtained in large amounts. Human SP-A, unlabeled or labeled with gold particles, was bound to freshly isolated macrophages and analyzed with ELISA or the transmission electron microscope. Binding of SP-A was inhibited by Ca2+ chelation, by an excess of unlabeled SP-A, or by the presence of 20 mg/ml mannan. We conclude that bovine alveolar macrophages expose binding sites for SP-A that are specific and that depend on Ca2+ and on mannose residues. For isolation of SP-A receptors with homologous SP-A as ligand we isolated SP-A from bovine lung lavage. SDS-PAGE analysis of the purified SP-A showed a protein of 32-36 kDa. Functional integrity of the protein was demonstrated. Bovine SP-A bound to Dynabeads was used to isolate SP-A binding proteins. From the fractionated and blotted proteins of the receptor preparation two proteins bound SP-A in a Ca2+-dependent manner, a 40-kDa protein showing mannose dependency and a 210-kDa protein, showing no mannose sensitivity. Copyright 1998 Academic Press.

  15. PreImplantation Factor (PIF) correlates with early mammalian embryo development-bovine and murine models

    PubMed Central

    2011-01-01

    Background PreImplantation Factor (PIF), a novel peptide secreted by viable embryos is essential for pregnancy: PIF modulates local immunity, promotes decidual pro-adhesion molecules and enhances trophoblast invasion. To determine the role of PIF in post-fertilization embryo development, we measured the peptide's concentration in the culture medium and tested endogenous PIF's potential trophic effects and direct interaction with the embryo. Methods Determine PIF levels in culture medium of multiple mouse and single bovine embryos cultured up to the blastocyst stage using PIF-ELISA. Examine the inhibitory effects of anti-PIF-monoclonal antibody (mAb) added to medium on cultured mouse embryos development. Test FITC-PIF uptake by cultured bovine blastocysts using fluorescent microscopy. Results PIF levels in mouse embryo culture medium significantly increased from the morula to the blastocyst stage (ANOVA, P = 0.01). In contrast, atretic embryos medium was similar to the medium only control. Detectable - though low - PIF levels were secreted already by 2-cell stage mouse embryos. In single bovine IVF-derived embryos, PIF levels in medium at day 3 of culture were higher than non-cleaving embryos (control) (P = 0.01) and at day 7 were higher than day 3 (P = 0.03). In non-cleaving embryos culture medium was similar to medium alone (control). Anti-PIF-mAb added to mouse embryo cultures lowered blastocyst formation rate 3-fold in a dose-dependent manner (2-way contingency table, multiple groups, X2; P = 0.01) as compared with non-specific mouse mAb, and medium alone, control. FITC-PIF was taken-up by cultured bovine blastocysts, but not by scrambled FITC-PIF (control). Conclusions PIF is an early embryo viability marker that has a direct supportive role on embryo development in culture. PIF-ELISA use to assess IVF embryo quality prior to transfer is warranted. Overall, our data supports PIF's endogenous self sustaining role in embryo development and the utility of PIF

  16. Fundamental study on reactivities of gluten protein types from wheat, rye and barley with five sandwich ELISA test kits.

    PubMed

    Lexhaller, Barbara; Tompos, Christine; Scherf, Katharina Anne

    2017-12-15

    Monitoring the compliance of gluten-free foods to the regulatory threshold of 20mg/kg of gluten is essential for celiac disease patients. The different enzyme-linked immunosorbent assays (ELISAs) for gluten detection each have specific characteristics, but there are only a few systematic comparisons. This fundamental study compared the specificities and sensitivities of the R5, G12 and Skerritt monoclonal and two polyclonal antibodies to well-defined gluten protein types (GPT) isolated from wheat, rye and barley flours. Quantitation of protein concentrations by reversed-phase high-performance liquid chromatography provided independent reference values. The ELISA responses showed high variability depending on the type of cereal, the GPT and the antibody used. Overall, ω1,2-gliadins and γ-75k-secalins were most reactive, whereas ω5-gliadins and γ-, B- and D-hordeins were detected with the lowest sensitivities. These results revealed which GPT each antibody is most sensitive to and provided novel insights that will be helpful for appropriate calibration of ELISAs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Cross-reactions of sera from dogs infected with Angiostrongylus vasorum in commercially available Dirofilaria immitis test kits.

    PubMed

    Schnyder, Manuela; Deplazes, Peter

    2012-11-13

    Dirofilaria immitis and Angiostrongylus vasorum are both important potentially fatal canine nematodes with overlapping endemic areas, especially in Europe. The preadult and adult stages of both species are living in the Arteria pulmonalis and the right heart, and diagnostically detectable circulating parasite antigens have been demonstrated for both species. For the detection of D. immitis infections, a variety of commercial tests have been developed, however, they have not been evaluated for cross-reactions against circulating antigens of A. vasorum. In this study, potential cross-reactions of sera from 16 dogs, which were experimentally infected with A. vasorum and which had circulating antigens as confirmed by a species-specific ELISA, were evaluated for the detection of A. vasorum antigen in six commercially available D. immitis test kits. In three fast tests (Witness® Dirofilaria, SensPERT® Canine Heartworm, SNAP® 4Dx® Plus), all sera were negative. One fast membrane ELISA (SNAP® HTWM RT Test) was positive with four sera (25%), and one serum delivered a non-valid result twice. In the PetChek® HTWM PF Test, depending on the interpretation protocol, 5 or 8 dogs (31.2 - 50%) were positive. With the DiroCHEK®-ELISA, a single A. vasorum-infected dog (6.2%) tested positive. Due to potential cross-reactions with A. vasorum in commercially available test kits for the detection of D. immitis antigen, the simultaneous use of highly specific diagnostic methods for the differentiation of these two canine heart worms is recommended.

  18. Development of an indirect ELISA based on the recombinant Spm2 protein for detection of tropical theileriosis.

    PubMed

    Tian, Zhancheng; Du, Xiaoyue; Du, Junzheng; Gao, Shandian; Yu, Ruiming; Hassan, Muhammad Adeel; Liu, Guangyuan; Luo, Jianxun; Yin, Hong

    2018-06-01

    Tropical theileriosis, caused by Theileria annulata, is distributed worldwide and causes great economic losses in dairy. The reliable diagnostic method is critical for prevention and control of the disease. In this study, a sporozoite and macroschizont gene 2 (spm2) protein from T. annulata was used to develop an indirect ELISA for tropical theileriosis. Specificity test showed that there were no cross-reactions with antibodies raised against other bovine piroplasm species using ELISA or western blotting. The specificity and sensitivity were 98.4% and 98.7%, respectively, with a threshold of 35.5% of the specific mean antibody rate (AbR). Furthermore, a total of 196 field sera samples collected from Xinjiang and Gansu provinces were detected by the spm2 ELISA and IFA. The results obtained with the spm2 ELISA and IFA in this study had the moderate agreement. The average positive rates of T. annulata sera samples detected in the present study were close to the prevalence of previous reports in these endemic areas. This indicated that the Spm2 ELISA could be used as a reliable diagnostic tool for serological survey of T. annulata infection in areas where Theileria parva is not present. Copyright © 2018 Elsevier B.V. All rights reserved.

  19. Comparative evaluation of three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of Nε-carboxymethyl lysine in food samples.

    PubMed

    Gómez-Ojeda, Armando; Jaramillo-Ortíz, Sarahi; Wrobel, Katarzyna; Wrobel, Kazimierz; Barbosa-Sabanero, Gloria; Luevano-Contreras, Claudia; de la Maza, Maria Pia; Uribarri, Jaime; Del Castillo, Ma Dolores; Garay-Sevilla, Ma Eugenia

    2018-03-15

    N ε -carboxymethyl-lysine (CML) is measured in food, but there is a controversy concerning the most convenient yet reliable method(s) for this task. This work compares three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of CML in several food items. The four methods showed the same decreasing order of CML concentration: beef, bacon>chicken > fish>dairy products>grain products>fruits/vegetables. HPLC-ESI-ITMS/MS results highly correlated with those obtained by ELISA performed with monoclonal CML-antibody (β=0.98, p<0.0001) whereas My Bio Source® kit results were not correlated with those provided by Lamider®. Small differences of CML concentrations in food items prepared by different culinary treatment were clearly distinguished by HPLC-ESI-ITMS/MS, but could not always be detected by ELISA. This work demonstrates a reasonable relationship between CM determined by ELISA and HPLC-ESI-ITMS/MS and therefore supports the implementation of ELISA in food CML/AGEs screening. Copyright © 2017. Published by Elsevier Ltd.

  20. Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.

    PubMed

    Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H

    2013-10-01

    Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Enzyme-antibody dual labeled gold nanoparticles probe for ultrasensitive detection of κ-casein in bovine milk samples.

    PubMed

    Li, Y S; Zhou, Y; Meng, X Y; Zhang, Y Y; Liu, J Q; Zhang, Y; Wang, N N; Hu, P; Lu, S Y; Ren, H L; Liu, Z S

    2014-11-15

    A dual labeled probe was synthesized by coating gold nanoparticles (AuNPs) with anti-κ-CN monoclonal antibody (McAb) and horseradish peroxidase (HRP) enzyme on their surface. The McAb was used as detector and HRP was used as label for signal amplification catalytically oxidize the substrate. AuNPs were used as bridges between the McAb and HRP. Based on the probe, an immunoassay was developed for ultrasensitive detection of κ-CN in bovine milk samples. The assay has a linear response range within 4.2-560 ng mL(-1). The limit of detection (LOD) was 4.2 ng mL(-1) which was 10 times lower than that of traditional McAb-HRP based ELISA. The recoveries of κ-CN from three brand bovine milk samples were from 95.8% to 111.0% that had a good correlation (R(2)=0.998) with those obtained by official standard Kjeldahl method. For higher sensitivity and as simple as the traditional ELISA, the developed immunoassay could provide an alternative approach for ultrasensitive detection of κ-CN in bovine milk sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  2. Tyrosine Kinase Inhibition in HPV-related Squamous Cell Carcinoma Reveals Beneficial Expression of cKIT and Src.

    PubMed

    Kramer, Benedikt; Kneissle, Marcel; Birk, Richard; Rotter, Nicole; Aderhold, Christoph

    2018-05-01

    Therapeutic options of locally advanced or metastatic head and neck squamous cell carcinoma (HNSCC) are limited. Src and cKIT are key protein regulators for local tumor progression. The aim of the study was to investigate the therapeutic potential of targeted therapies in human squamous cell carcinoma (HNSCC) in vitro. Therefore, the influence of the selective tyrosine kinase inhibitors niotinib, dasatinib, erlotinib, gefitinib and afatinib on Src and cKIT expression in Human papilloma virus (HPV)-positive and HPV-negative squamous cancer cells (SCC) was analyzed in vitro. ELISA was performed to evaluate the expression of Src and cKIT under the influence of nilotinib, dasatinib, erlotinib, gefitinib and afatinib (10 μmol/l) in HPV-negative and HPV-positive SCC (24-96 h of incubation). Gefitinib significantly increased cKIT expression in HPV-positive and HPV-negative cells whereas nilotinib and afatinib decreased cKIT expression in HPV-positive SCC. The influence of tyrosine kinase inhibitors in HPV-negative SCC was marginal. Surprisingly, Src expression was significantly increased by all tested tyrosine kinase inhibitors in HPV-positive SCC. The results revealed beneficial and unexpected information concerning the interaction of selective tyrosine kinase inhibitors and the tumor biology of HNSCC. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  3. Development of monoclonal antibody-based sandwich ELISA for detection of dextran.

    PubMed

    Wang, Sheng-Yu; Li, Zhe; Wang, Xian-Jiang; Lv, Sha; Yang, Yun; Zeng, Lian-Qiang; Luo, Fang-Hong; Yan, Jiang-Hua; Liang, Da-Feng

    2014-10-01

    Dextran as anti-nutritional factor is usually a result of bacteria activity and has associated serial problems during the process stream in the sugar industry and in medical therapy. A sensitive method is expected to detect dextran quantitatively. Here we generated four monoclonal antibodies (MAbs) against dextran using dextran T40 conjugated with bovine serum albumin (BSA) as immunogen in our lab following hybridoma protocol. Through pairwise, an MAb named D24 was determined to be conjugated with horseradish peroxidase (HRP) and was used in the establishment of a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) method for determination of dextran, in which MAb D9 was chosen as a capture antibody. The detection limit and working scope of the developed sandwich ELISA method were 3.9 ng/mL and 7.8-500 ng/mL with a correlation coefficient of 0.9909. In addition, the cross-reaction assay demonstrated that the method possessed high specificity with no significant cross-reaction with dextran-related substances, and the recovery rate ranged from 96.35 to 102.00%, with coefficient of variation ranging from 1.58 to 6.94%. These results indicated that we developed a detection system of MAb-based sandwich ELISA to measure dextran and this system should be a potential tool to determine dextran levels.

  4. Development of Rapid Diagnostic Kit for Identification of Hanwoo (Korean Native Cattle) Brand Meat by Detecting BIO-TAG

    PubMed Central

    Park, Sung Kwon; Lee, Myung Hoon; Cho, Soo Hyun

    2014-01-01

    This study was performed to develop a rapid immuno-assay kit, by using a specific antigen to detect Hanwoo brand meat. We selected a synthetic antigen specific to our target antibody, named BIO-TAG (Tyr-D-Ala-Phe), by utilizing a computer-based analysis and literature review. BIO-TAG tagged with adjuvant was subcutaneously injected in sheep and Hanwoo. The serum and meat juice of the immunized or non-immunized animal were then analyzed, to measure the titer of antibody by ELISA and Western blot. The amount of antibodies against the BIO-TAG increased (p<0.05) in serum by vaccination. Furthermore, meat juice from the immunized Hanwoo showed greater (p<0.05) antibody titer, compared with those from non-immunized groups. To optimze the dilution factor, we performed dot-ELISA, with various combination levels of BIO-TAG. Results from dot-ELISA showed that 2 mg/mL BIO-TAG was sufficient to distinguish the immunized meat from non-immunized groups. These results support our hypothesis that simple immunization of Hanwoo generates a sufficient amount of antibodies to be detectable in the meat juice by means of the immune-assay. Therefore, specific Hanwoo brand meat can be more precisely identified by our rapid diagnostic kit. This technology can deter possible fraud of counterfeit meat brands in the Korean domestic market with ease and rapidity; and offers a new tool that guarantees consumers high quality Hanwoo brand beef. PMID:26761175

  5. A multiplex competitive ELISA for the detection and characterization of gluten in fermented-hydrolyzed foods.

    PubMed

    Panda, Rakhi; Boyer, Marc; Garber, Eric A E

    2017-12-01

    A novel competitive ELISA was developed utilizing the G12, R5, 2D4, MIoBS, and Skerritt antibody-HRP conjugates employed in nine commercial ELISA test kits that are routinely used for gluten detection. This novel multiplex competitive ELISA simultaneously measures gliadin-, deamidated gliadin-, and glutenin-specific epitopes. The assay was used to evaluate 20 wheat beers, 20 barley beers, 6 barley beers processed to reduce gluten, 15 soy sauces, 6 teriyaki sauces, 6 Worcestershire sauces, 6 vinegars, and 8 sourdough breads. For wheat beers, the apparent gluten concentration values obtained by the G12 and Skerritt antibodies were typically higher than those obtained using the R5 antibodies. The sourdough bread samples resulted in higher apparent gluten concentration values with the Skerritt antibody, while the values generated by the G12 and R5 antibodies were comparable. Although the soy-based sauces showed non-specific inhibition with the multiple R5 and G12 antibodies, their overall profile was distinguishable from the other categories of fermented foods. Cluster analysis of the apparent gluten concentration values obtained by the multiplex competitive ELISA, as well as the relative response of the nine gluten-specific antibodies used in the assay to different gluten proteins/peptides, distinguishes among the different categories of fermented-hydrolyzed foods by recognizing the differences in the protein/peptide profiles characteristic of each product. This novel gluten-based multiplex competitive ELISA provides insight into the extent of proteolysis resulting from various fermentation processes, which is essential for accurate gluten quantification in fermented-hydrolyzed foods. Graphical abstract A novel multiplex competitive ELISA for the detection and characterization of gluten in fermented-hydrolyzed foods.

  6. Performance characteristics of an ELISA screening assay for urinary synthetic cannabinoids.

    PubMed

    Spinelli, Eliani; Barnes, Allan J; Young, Sheena; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A

    2015-06-01

    Synthetic cannabinoids are marketed as legal alternatives to cannabis, as routine urine cannabinoid immunoassays do not detect synthetic cannabinoids. Laboratories are challenged to identify these new designer drugs that are widely available and represent a major public health and safety problem. Immunoassay testing offers rapid separation of presumptive positive and negative specimens, prior to more costly and time-consuming chromatographic confirmation. The Neogen SPICE ELISA kit targets JWH-018 N-pentanoic acid as a marker for urinary synthetic cannabinoids. Assay performance was evaluated by analyzing 2469 authentic urine samples with the Neogen immunoassay and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Two immunoassay cut-off concentrations, 5 and 10 µg/L, classified samples as presumptive positive or negative, followed by qualitative LC-MS/MS confirmation for 29 synthetic cannabinoids markers with limits of detection of 0.5-10 µg/L to determine the assay's sensitivity, specificity and efficacy. Challenges at ±25% of each cut-off also were investigated to determine performance around the cut-off and intra- and inter-plate imprecision. The immunoassay was linear from 1 to 250 µg/L (r(2)  = 0.992) with intra- and inter-plate imprecision of ≤5.3% and <9%, respectively. Sensitivity, specificity, and efficiency results with the 5 µg/L cut-off were 79.9%, 99.7%, and 97.4% and with the 10 µg/L cut-off 69.3%, 99.8%, and 96.3%, respectively. Cross-reactivity was shown for 18 of 73 synthetic cannabinoids markers evaluated. Good sensitivity, specificity, and efficiency, lack of sample preparation requirements, and rapid semi-automation documented that the Neogen SPICE ELISA kit is a viable method for screening synthetic cannabinoids in urine targeting JWH-018 N-pentanoic acid. Copyright © 2014 John Wiley & Sons, Ltd.

  7. GridKit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peles, Slaven

    2016-11-06

    GridKit is a software development kit for interfacing power systems and power grid application software with high performance computing (HPC) libraries developed at National Labs and academia. It is also intended as interoperability layer between different numerical libraries. GridKit is not a standalone application, but comes with a suite of test examples illustrating possible usage.

  8. A competitive ELISA for species-independent detection of Crimean-Congo hemorrhagic fever virus specific antibodies.

    PubMed

    Schuster, Isolde; Mertens, Marc; Köllner, Bernd; Korytář, Tomáš; Keller, Markus; Hammerschmidt, Bärbel; Müller, Thomas; Tordo, Noël; Marianneau, Philippe; Mroz, Claudia; Rissmann, Melanie; Stroh, Eileen; Dähnert, Lisa; Hammerschmidt, Felicitas; Ulrich, Rainer G; Groschup, Martin H

    2016-10-01

    Crimean-Congo hemorrhagic fever virus (CCHFV) circulates in many countries of Asia, Africa, and Europe. CCHFV can cause a severe hemorrhagic fever in humans with case-fatality rates of up to 80%. CCHF is considered to be one of the major emerging diseases spreading to and within Europe. Ticks of the genus Hyalomma function as vector as well as natural reservoir of CCHFV. Ticks feed on various domestic animals (e.g. cattle, sheep, goats) and on wildlife (e.g. hares, hedgehogs). Those animal species play an important role in the life cycle of the ticks as well as in amplification of CCHFV. Here we present a competitive ELISA (cELISA) for the species-independent detection of CCHFV-specific antibodies. For this purpose nucleocapsid (N) protein specific monoclonal antibodies (mAbs) were generated against an Escherichia coli (E. coli) expressed CCHFV N-protein. Thirty-three mAbs reacted with homologous and heterologous recombinant CCHFV antigens in ELISA and Western blot test and 20 of those 33 mAbs reacted additionally in an immunofluorescence assay with eukaryotic cells expressing the N-protein. Ten mAbs were further characterized in a prototype of the cELISA and nine of them competed with positive control sera of bovine origin. The cELISA was established by using the mAb with the strongest competition. For the validation, 833 sera from 12 animal species and from humans were used. The diagnostic sensitivity and specificity of the cELISA was determined to be 95% and 99%, respectively, and 2% of the sera gave inconclusive results. This cELISA offers the possibility for future large-scale screening approaches in various animal species to evaluate their susceptibility to CCHFV infection and to identify and monitor the occurrence of CCHFV. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Cross-reactions of sera from dogs infected with Angiostrongylus vasorum in commercially available Dirofilaria immitis test kits

    PubMed Central

    2012-01-01

    Background Dirofilaria immitis and Angiostrongylus vasorum are both important potentially fatal canine nematodes with overlapping endemic areas, especially in Europe. The preadult and adult stages of both species are living in the Arteria pulmonalis and the right heart, and diagnostically detectable circulating parasite antigens have been demonstrated for both species. For the detection of D. immitis infections, a variety of commercial tests have been developed, however, they have not been evaluated for cross-reactions against circulating antigens of A. vasorum. Methods In this study, potential cross-reactions of sera from 16 dogs, which were experimentally infected with A. vasorum and which had circulating antigens as confirmed by a species-specific ELISA, were evaluated for the detection of A. vasorum antigen in six commercially available D. immitis test kits. Results In three fast tests (Witness® Dirofilaria, SensPERT® Canine Heartworm, SNAP® 4Dx® Plus), all sera were negative. One fast membrane ELISA (SNAP® HTWM RT Test) was positive with four sera (25%), and one serum delivered a non-valid result twice. In the PetChek® HTWM PF Test, depending on the interpretation protocol, 5 or 8 dogs (31.2 – 50%) were positive. With the DiroCHEK®-ELISA, a single A. vasorum-infected dog (6.2%) tested positive. Conclusions Due to potential cross-reactions with A. vasorum in commercially available test kits for the detection of D. immitis antigen, the simultaneous use of highly specific diagnostic methods for the differentiation of these two canine heart worms is recommended. PMID:23148786

  10. 77 FR 29914 - Bovine Spongiform Encephalopathy; Importation of Bovines and Bovine Products

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-21

    ... Spongiform Encephalopathy; Importation of Bovines and Bovine Products AGENCY: Animal and Plant Health... derived from bovines with regard to bovine spongiform encephalopathy. This action will allow interested... importation of live bovines and products derived from bovines with regard to bovine spongiform encephalopathy...

  11. Telescience Resource Kit

    NASA Technical Reports Server (NTRS)

    Schneider, Michelle

    2003-01-01

    This viewgraph representation provides an overview of the Telescience Resource Kit. The Telescience Resource Kit is a pc-based telemetry and command system that will be used by scientists and engineers to monitor and control experiments located on-board the International Space Station (ISS). Topics covered include: ISS Payload Telemetry and Command Flow, kit computer applications, kit telemetry capabilities, command capabilities, and training/testing capabilities.

  12. Diagnosis of paratuberculosis by fecal culture and ELISA on milk and serum samples in two types of Chilean dairy goat herds.

    PubMed

    Salgado, Miguel; Kruze, Juan; Collins, Michael T

    2007-01-01

    Fecal culture has been the primary method used to diagnose paratuberculosis in goats. It is laborious, slow, and expensive. Validation of enzyme-linked immunosorbent assays (ELISAs) on milk samples could make paratuberculosis testing more widely available for goat farmers. The aim of this study was to determine the accuracy of serum and milk ELISAs for paratuberculosis, relative to fecal culture, in Chilean dairy goats. Eight dairy goat herds were selected. Feces, blood, and milk samples were collected from all female goats >2 years old. Fecal samples were cultured using Herrold egg yolk medium with mycobactin J and antibiotics. Serum and milk samples were tested using a commercial ELISA kit for Mycobacterium avium subsp. paratuberculosis antibody detection. A total of 383 goats were tested by ELISA and fecal culture. The sensitivity of ELISA on serum and milk relative to fecal culture was 74.3% (95% CI: 59.8-88.8) and 60% (95% CI: 43.8-76.2), respectively. The corresponding values for ELISA specificity based on the percentage of non- M. avium subsp. paratuberculosis-infected goats testing ELISA-negative were 98.6% (95% CI: 96.6-100) and 99.3% (95% CI: 97.9-100) on serum and milk, respectively. Proportions of positive results for serum and fecal samples were significantly different, whereas the proportions of positive results for milk and fecal samples were not significantly different. The milk ELISA had a moderate level of agreement with fecal culture results (Kappa = 0.57). The paratuberculosis ELISA on goat milk samples may be a cost-effective, accurate alternative to fecal culture.

  13. Development and validation of an epitope-blocking ELISA using an anti-haemagglutinin monoclonal antibody for specific detection of antibodies in sheep and goat sera directed against peste des petits ruminants virus.

    PubMed

    Bodjo, Sanne Charles; Baziki, Jean-de-Dieu; Nwankpa, Nick; Chitsungo, Ethel; Koffi, Yao Mathurin; Couacy-Hymann, Emmanuel; Diop, Mariame; Gizaw, Daniel; Tajelser, Idris Badri Adam; Lelenta, Mamadou; Diallo, Adama; Tounkara, Karim

    2018-07-01

    Peste des petits ruminants (PPR) is a contagious and economically important disease affecting production of small ruminants (i.e., sheep and goats). Taking into consideration the lessons learnt from the Global Rinderpest Eradication Programme (GREP), PPR is now targeted by the international veterinary community as the next animal disease to be eradicated. To support the African continental programme for the control of PPR, the Pan African Veterinary Vaccine Centre of the African Union (AU-PANVAC) is developing diagnostics tools. Here, we describe the development of a blocking enzyme-linked immunosorbent assay (bELISA) that allows testing of a large number of samples for specific detection of antibodies directed against PPR virus in sheep and goat sera. The PPR bELISA uses an anti-haemagglutinin (H) monoclonal antibody (MAb) as a competitor antibody, and tests results are interpreted using the percentage of inhibition (PI) of MAb binding generated by the serum sample. PI values below or equal to 18% (PI ≤ 18%) are negative, PI values greater than or equal to 25% (PI ≥ 25%) are positive, and PI values greater than 18% and below 25% are doubtful. The diagnostic specificity (DSp) and diagnostic sensitivity (DSe) were found to be 100% and 93.74%, respectively. The H-based PPR-bELISA showed good correlation with the virus neutralization test (VNT), the gold standard test, with a kappa value of 0.947. The H-based PPR-bELISA is more specific than the commercial kit ID Screen® PPR Competition (N-based PPR-cELISA) from IDvet (France), but the commercial kit is slightly more sensitive than the H-based PPR-bELISA. The validation process also indicated good repeatability and reproducibility of the H-based PPR-bELISA, making this new test a suitable tool for the surveillance and sero-monitoring of the vaccination campaign.

  14. High seroprevalence of Mycoplasma pneumoniae IgM in acute Q fever by enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Lai, Chung-Hsu; Chang, Lin-Li; Lin, Jiun-Nong; Chen, Wei-Fang; Kuo, Li-Li; Lin, Hsi-Hsun; Chen, Yen-Hsu

    2013-01-01

    Q fever is serologically cross-reactive with other intracellular microorganisms. However, studies of the serological status of Mycoplasma pneumoniae and Chlamydophila pneumoniae during Q fever are rare. We conducted a retrospective serological study of M. pneumoniae and C. pneumoniae by enzyme-linked immunosorbent assay (ELISA), a method widely used in clinical practice, in 102 cases of acute Q fever, 39 cases of scrub typhus, and 14 cases of murine typhus. The seropositive (57.8%, 7.7%, and 0%, p<0.001) and seroconversion rates (50.6%, 8.8%, and 0%, p<0.001) of M. pneumoniae IgM, but not M. pneumoniae IgG and C. pneumoniae IgG/IgM, in acute Q fever were significantly higher than in scrub typhus and murine typhus. Another ELISA kit also revealed a high seropositivity (49.5%) and seroconversion rate (33.3%) of M. pneumoniae IgM in acute Q fever. The temporal and age distributions of patients with positive M. pneumoniae IgM were not typical of M. pneumoniae pneumonia. Comparing acute Q fever patients who were positive for M. pneumoniae IgM (59 cases) with those who were negative (43 cases), the demographic characteristics and underlying diseases were not different. In addition, the clinical manifestations associated with atypical pneumonia, including headache (71.2% vs. 81.4%, p=0.255), sore throat (8.5% vs. 16.3%, p=0.351), cough (35.6% vs. 23.3%, p=0.199), and chest x-ray suggesting pneumonia (19.3% vs. 9.5%, p=0.258), were unchanged between the two groups. Clinicians should be aware of the high seroprevalence of M. pneumoniae IgM in acute Q fever, particularly with ELISA kits, which can lead to misdiagnosis, overestimations of the prevalence of M. pneumoniae pneumonia, and underestimations of the true prevalence of Q fever pneumonia.

  15. High Seroprevalence of Mycoplasma pneumoniae IgM in Acute Q Fever by Enzyme-Linked Immunosorbent Assay (ELISA)

    PubMed Central

    Lai, Chung-Hsu; Chang, Lin-Li; Lin, Jiun-Nong; Chen, Wei-Fang; Kuo, Li-Li; Lin, Hsi-Hsun; Chen, Yen-Hsu

    2013-01-01

    Q fever is serologically cross-reactive with other intracellular microorganisms. However, studies of the serological status of Mycoplasma pneumoniae and Chlamydophila pneumoniae during Q fever are rare. We conducted a retrospective serological study of M. pneumoniae and C. pneumoniae by enzyme-linked immunosorbent assay (ELISA), a method widely used in clinical practice, in 102 cases of acute Q fever, 39 cases of scrub typhus, and 14 cases of murine typhus. The seropositive (57.8%, 7.7%, and 0%, p<0.001) and seroconversion rates (50.6%, 8.8%, and 0%, p<0.001) of M. pneumoniae IgM, but not M. pneumoniae IgG and C. pneumoniae IgG/IgM, in acute Q fever were significantly higher than in scrub typhus and murine typhus. Another ELISA kit also revealed a high seropositivity (49.5%) and seroconversion rate (33.3%) of M. pneumoniae IgM in acute Q fever. The temporal and age distributions of patients with positive M. pneumoniae IgM were not typical of M. pneumoniae pneumonia. Comparing acute Q fever patients who were positive for M. pneumoniae IgM (59 cases) with those who were negative (43 cases), the demographic characteristics and underlying diseases were not different. In addition, the clinical manifestations associated with atypical pneumonia, including headache (71.2% vs. 81.4%, p=0.255), sore throat (8.5% vs. 16.3%, p=0.351), cough (35.6% vs. 23.3%, p=0.199), and chest x-ray suggesting pneumonia (19.3% vs. 9.5%, p=0.258), were unchanged between the two groups. Clinicians should be aware of the high seroprevalence of M. pneumoniae IgM in acute Q fever, particularly with ELISA kits, which can lead to misdiagnosis, overestimations of the prevalence of M. pneumoniae pneumonia, and underestimations of the true prevalence of Q fever pneumonia. PMID:24147043

  16. Development of a competitive ELISA using a truncated E2 recombinant protein as antigen for detection of antibodies to classical swine fever virus.

    PubMed

    Clavijo, A; Lin, M; Riva, J; Mallory, M; Lin, F; Zhou, E M

    2001-02-01

    The sequence encoding a truncated E2 glycoprotein of the Alfort/187 strain of classical swine fever virus (CSFV) was expressed in Escherichia coli using the pET expression system and the recombinant product purified by Ni-NTA agarose affinity chromatography. The antigenicity of this recombinant protein was demonstrated by immunoblot using anti- CSFV-specific antibodies. A monoclonal antibody was produced against the truncated E2 protein and used as competitor in an ELISA for the detection of antibodies to CSFV. Specific antibodies were demonstrated by competitive ELISA (C-ELISA) as early as 21 days post-infection (dpi) in experimentally infected pigs. Seroconversion was demonstrated by C-ELISA and neutralising peroxidase-linked assay (NPLA) in all infected animals by 4 weeks. No cross-reaction with antibodies to bovine viral diarrhoea virus (BVDV) was seen in the C-ELISA using sera from experimentally infected pigs. The C-ELISA is not intended as a substitute for the NPLA. However, it is expected it will be useful for monitoring and prevalence studies. It will also assist in testing a large number of samples in the event of an outbreak. Copyright 2001 Harcourt Publishers Ltd.

  17. First Results in the Use of Bovine Ear Notch Tag for Bovine Viral Diarrhoea Virus Detection and Genetic Analysis

    PubMed Central

    Quinet, Christian; Czaplicki, Guy; Dion, Elise; Dal Pozzo, Fabiana; Kurz, Anke; Saegerman, Claude

    2016-01-01

    Background Infection due to bovine viral diarrhoea virus (BVDV) is endemic in most cattle-producing countries throughout the world. The key elements of a BVDV control programme are biosecurity, elimination of persistently infected animals and surveillance. Bovine viral diarrhoea (BVD) is a notifiable disease in Belgium and an official eradication programme started from January 2015, based on testing ear notches sampled during the official identification and registration of calves at birth. An antigen-capture ELISA test based on the detection of BVDV Erns protein is used. Ear notch sample may also be used to characterize the genotype of the calf when appropriate elution/dilution buffer is added. Both BVDV antigen-ELISA analysis and animal traceability could be performed. Methodology With regards to the reference protocol used in the preparation of ear notch samples, alternative procedures were tested in terms of BVDV analytic sensitivity, diagnostic sensitivity and specificity, as well as quality and purity of animal DNA. Principal Findings/Significance The Allflex DNA Buffer D showed promising results in BVDV diagnosis and genome analyses, opening new perspectives for the livestock industry by the exploitation of the animal genome. Due to the high number of cattle involved in the Belgian official BVDV eradication programme based on ear notch tags sample, a large database on both BVDV status of newborn calves and cattle genome could be created for subsequent different uses (e.g. traceability, determination of parentage, genetic signatures throughout the genome associated with particular traits) evolving through a more integrated animal health. PMID:27764130

  18. Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method

    PubMed Central

    Baker, Harold N.; Murphy, Robin; Lopez, Erica; Garcia, Carlos

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) has long been the primary tool for detection of analytes of interest in biological samples for both life science research and clinical diagnostics. However, ELISA has limitations. It is typically performed in a 96-well microplate, and the wells are coated with capture antibody, requiring a relatively large amount of sample to capture an antigen of interest . The large surface area of the wells and the hydrophobic binding of capture antibody can also lead to non-specific binding and increased background. Additionally, most ELISAs rely upon enzyme-mediated amplification of signal in order to achieve reasonable sensitivity. Such amplification is not always linear and can thus skew results. In the past 15 years, a new technology has emerged that offers the benefits of the ELISA, but also enables higher throughput, increased flexibility, reduced sample volume, and lower cost, with a similar workflow 1, 2. Luminex xMAP Technology is a microsphere (bead) array platform enabling both monoplex and multiplex assays that can be applied to both protein and nucleic acid applications 3-5. The beads have the capture antibody covalently immobilized on a smaller surface area, requiring less capture antibody and smaller sample volumes, compared to ELISA, and non-specific binding is significantly reduced. Smaller sample volumes are important when working with limiting samples such as cerebrospinal fluid, synovial fluid, etc. 6. Multiplexing the assay further reduces sample volume requirements, enabling multiple results from a single sample. Recent improvements by Luminex include: the new MAGPIX system, a smaller, less expensive, easier-to-use analyzer; Low-Concentration Magnetic MagPlex Microspheres which eliminate the need for expensive filter plates and come in a working concentration better suited for assay development and low-throughput applications; and the xMAP Antibody Coupling (AbC) Kit, which includes a protocol, reagents, and

  19. Serodiagnosis of bovine trypanosomosis caused by non-tsetse transmitted Trypanosoma (Duttonella) vivax parasites using the soluble form of a Trypanozoon variant surface glycoprotein antigen.

    PubMed

    Uzcanga, Graciela L; Pérez-Rojas, Yenis; Camargo, Rocío; Izquier, Adriana; Noda, José A; Chacín, Ronny; Parra, Nereida; Ron, Lenin; Rodríguez-Hidalgo, Richar; Bubis, José

    2016-03-15

    Previous studies have shown that a 64-kDa antigen (p64) that was purified from the Venezuelan TeAp-N/D1 isolate of Trypanosoma (Trypanozoon) equiperdum corresponds to the soluble form of its predominant variant surface glycoprotein (VSG), and exhibited cross-reactivity with Trypanosoma (Duttonella) vivax. The course of experimental acute infections of bovines with T. vivax were followed by measuring whole anti-p64 antibodies and specific anti-p64 IgG and IgM antibodies in animal sera by indirect enzyme-linked immunosorbent assay (ELISA). The value of p64 to diagnose bovine trypanosomosis was also examined using 350 sera from healthy and T. vivax-infected cows living in a trypanosomosis-endemic and enzootic stable area, and 48 sera obtained during a trypanosomosis outbreak. Serological assays showed that ∼ 70-80% of the infected sera contained anti-p64 antibodies, based on the comparative immunodetection of the T. equiperdum clarified antigenic fraction used as a reference test. In the absence of a gold standard, Bayesian analysis for multiple testing estimated a sensitivity and specificity of 71.6% and 98.8%, respectively, for the indirect ELISA using p64 as antigen. An apparent prevalence of 37.7% for bovine trypanosomosis infection was also estimated with a Bayesian approach when the p64 ELISA test was used. Employing blood from acute infected cows, the indirect ELISA response against p64 was contrasted with the microhematocrit centrifuge method and analyses by polymerase chain reaction (PCR) using specific primers targeting the inter-specific length variation of the internal transcribed spacer 1 region of the 18S ribosomal gene. The efficiency of p64 for the detection of anti-trypanosome antibodies in acute infected bovines was also corroborated serologically by comparing its response to that of the Indonesian Trypanosoma evansi Rode Trypanozoon antigen type (RoTat) 1.2 VSG, which possesses high specificity and sensitivity. As expected, PCR was the best

  20. ELISA-BASE: An Integrated Bioinformatics Tool for Analyzing and Tracking ELISA Microarray Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Amanda M.; Collett, James L.; Seurynck-Servoss, Shannon L.

    ELISA-BASE is an open-source database for capturing, organizing and analyzing protein enzyme-linked immunosorbent assay (ELISA) microarray data. ELISA-BASE is an extension of the BioArray Soft-ware Environment (BASE) database system, which was developed for DNA microarrays. In order to make BASE suitable for protein microarray experiments, we developed several plugins for importing and analyzing quantitative ELISA microarray data. Most notably, our Protein Microarray Analysis Tool (ProMAT) for processing quantita-tive ELISA data is now available as a plugin to the database.

  1. Assessment of the repeatability and border-plate effects of the B158/B60 enzyme-linked-immunosorbent assay for the detection of circulating antigens (Ag-ELISA) of Taenia saginata.

    PubMed

    Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah

    2016-08-30

    The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Bovine herpesvirus 1: within-herd seroprevalence and antibody levels in bulk-tank milk.

    PubMed

    Martínez, S; Yus, E; Sanjuán, M L; Camino, F; Eiras, M C; Arnaiz, I; Diéguez, F J

    2016-12-01

    The aim of the present study was to establish a relationship between the results obtained with the enzyme-linked immunosorbent assay (ELISA) technique for antibodies (against bovine herpesvirus 1) in serum and those in milk at the herd level. For this purpose, 275 samples of bulk-tank milk were analysed with glycoprotein E (gE) antibody ELISA and 207 more were analysed with glycoprotein B (gB) antibody ELISA (482 in total). All of these samples came from dairy herds whose seroprevalence was also evaluated. The results of this study were then used to analyse the sensitivity of the bulk-tankmilk test in detecting herds with a high risk of active infection (>60% seroprevalence) and its specificity in detecting those with few (<20%) or no seropositive animals. In regard to the reference test (results in blood serum), the sensitivity of the bulk-tankmilk test in detecting herds with >60% seropositive animals was 100% for both gE and gB ELISAs. The specificity figures, for gE and gB ELISAs, respectively, were 88.4% and 99.1% for infection-free herds and 72.6% and 96% for herds with <20% seroprevalence. In a quantitative approach, Pearson's correlation coefficients, reported as a measure of linear association between herd seroprevalences and transformed optical density values recorded in bulk-tank milk, were -0.63 for gE ELISA and 0.67 for gB ELISA. © OIE (World Organisation for Animal Health), 2016.

  3. Preparation of peanut butter suspension for determination of peanuts using enzyme-linked immunoassay kits.

    PubMed

    Trucksess, Mary W; Brewer, Vickery A; Williams, Kristina M; Westphal, Carmen D; Heeres, James T

    2004-01-01

    Peanuts are one of the 8 most common allergenic foods and a large proportion of peanut-allergic individuals have severe reactions, some to minimal exposure. Specific protein constituents in the peanuts are the cause of the allergic reactions in sensitized individuals who ingest the peanuts. To avoid accidental ingestion of peanut-contaminated food, methods of analysis for the determination of the allergenic proteins in foods are important tools. Such methods could help identify foods inadvertently contaminated with peanuts, thereby reducing the incidence of allergic reactions to peanuts. Commercial immunoassay kits are available but need study for method performance, which requires reference materials for within- and between-laboratory validations. In this study, National Institute of Standards and Technology Standard Reference Material 2387 peanut butter was used. A polytron homogenizer was used to prepare a homogenous aqueous Peanut Butter suspension for the evaluation of method performance of some commercially available immunoassay kits such as Veratox for Peanut Allergen Test (Neogen Corp.), Ridascreen Peanut (R-Biopharm GmbH), and Bio-Kit Peanut Protein Assay Kit (Tepnel). Each gram of the aqueous peanut butter suspension contained 20 mg carboxymethylcellulose sodium salt, 643 microg peanut, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. The suspension was homogenous, stable, reproducible, and applicable for adding to ice cream, cookies, breakfast cereals, and chocolate for recovery studies at spike levels ranging from 12 to 90 microg/g.

  4. Comparative assessment of two commonly used commercial ELISA tests for the serological diagnosis of contagious agalactia of small ruminants caused by Mycoplasma agalactiae

    PubMed Central

    2012-01-01

    Background Contagious agalactia (CA) of sheep and goats caused by Mycoplasma agalactiae is a widely occurring economically important disease that is difficult to control. The ELISA is commonly used for the serological detection of CA but it has some limitations and the performance of the available tests have not been properly evaluated. Two commercial ELISA kits are widely used, one involving a fusion protein as target antigen and the other a total antigen. The objectives were to compare these tests by evaluating: i. Their diagnostic sensitivity and specificity, the relevance of the recommended cut-off points, the correlation between the two tests, and, the correlation between serology data and the milk shedding of M. agalatiae; ii. The influence of extrinsic factors such as the targeted animal species, geographical origin of the samples, intra-specific variability of M. agalactiae and concurrent mycoplasma infections. A sample of 5900 animals from 211 farms with continuous CA monitoring for 20 years and no prior vaccination history was used. The infection status was known from prior bacteriological, epidemiological and serological monitoring with a complementary immunoblotting test. Results The average diagnostic sensitivity was 56% [51.8–59.8] for the fusion protein ELISA and 84% [81.3–87.2] for the total antigen ELISA, with noteworthy flock-related variations. The average diagnostic specificity for the fusion protein ELISA was 100% [99.9–100], and for the total antigen ELISA differed significantly between goats and sheep: 99.3% [97.4–99.9] and 95.7% [93.8–97.2] respectively. Experimental inoculations with different M. agalactiae strains revealed that the ELISA kits poorly detected the antibody response to certain strains. Furthermore, test performances varied according to the host species or geographical origin of the samples. Finally, the correlation between milk shedding of M. agalactiae and the presence of detectable antibodies in the blood was

  5. Determining the feline immunodeficiency virus (FIV) status of FIV-vaccinated cats using point-of-care antibody kits.

    PubMed

    Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M

    2015-10-01

    This study challenges the commonly held view that the feline immunodeficiency virus (FIV) infection status of FIV-vaccinated cats cannot be determined using point-of-care antibody test kits due to indistinguishable antibody production in FIV-vaccinated and naturally FIV-infected cats. The performance of three commercially available point-of-care antibody test kits was compared in a mixed population of FIV-vaccinated (n=119) and FIV-unvaccinated (n=239) cats in Australia. FIV infection status was assigned by considering the results of all antibody kits in concert with results from a commercially available PCR assay (FIV RealPCR™). Two lateral flow immunochromatography test kits (Witness FeLV/FIV; Anigen Rapid FIV/FeLV) had excellent overall sensitivity (100%; 100%) and specificity (98%; 100%) and could discern the true FIV infection status of cats, irrespective of FIV vaccination history. The lateral flow ELISA test kit (SNAP FIV/FeLV Combo) could not determine if antibodies detected were due to previous FIV vaccination, natural FIV infection, or both. The sensitivity and specificity of FIV RealPCR™ for detection of viral and proviral nucleic acid was 92% and 99%, respectively. These results will potentially change the way veterinary practitioners screen for FIV in jurisdictions where FIV vaccination is practiced, especially in shelter scenarios where the feasibility of mass screening is impacted by the cost of testing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  6. Clinical report: Detection and management of bovine viral diarrhea virus Type 1b in a large dairy herd

    USDA-ARS?s Scientific Manuscript database

    Case Description: 1,081 newborn calves from a commercial dairy were tested for bovine viral diarrhea virus antigen by pooled RT-PCR as part of a screening program. Ear tissue from twenty six calves initially tested positive and 14 confirmed positive with antigen capture ELISA two weeks later (1.3...

  7. Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Durant, J.T.

    Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. Themore » dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.« less

  8. Detection of pregnancy in sheep using an ELISA for pregnancy-specific protein B.

    PubMed

    Milisits-Németh, Tímea; Balogh, Orsolya Gabriella; Egerszegi, István; Kern, László; Sasser, R Garth; Gábor, György

    2018-06-01

    The early detection of pregnancy and the determination of fetal numbers have economic benefits in sheep production because of the seasonal breeding patterns where missing a breeding opportunity means the loss of one productive year. The purpose of this study was to evaluate the efficacy of the B6-HRP ELISA for ovine pregnancy-specific protein B (oPSPB) measurement in the detection of pregnancy and estimation of fetal numbers in different sheep breeds. BioPRYN® ELISA assay kit was used for the detection of pregnancy in the experimental animals. Ninety-three ewes of three breeds (British Milksheep - BM, Lacaune - L and Transylvanian Racka - TR), each from three farms in Hungary, were included in the study. BM and L ewes were artificially inseminated (AI). Thirty-five days after AI, all ewes were examined by transabdominal ultrasound. The TR flock was mated naturally over a six-week period. At the end of the mating period, the ewes were similarly examined by ultrasound. Blood samples were taken from all pregnant ewes twice (35 and 65 days after AI), and serum samples were assayed by the BioPRYN test. It can be concluded that the detection of serum PSPB by ELISA is a much easier, safer, less expensive and highly accurate method for the detection of ovine pregnancy. Although some breed-related differences were detectable at 35 and 65 days post breeding, no differences in oPSPB levels were found in pregnant ewes carrying different numbers of fetuses.

  9. Evidence of shared bovine viral diarrhea infections between red deer and extensively raised cattle in south-central Spain.

    PubMed

    Rodríguez-Prieto, Víctor; Kukielka, Deborah; Rivera-Arroyo, Belén; Martínez-López, Beatriz; de las Heras, Ana Isabel; Sánchez-Vizcaíno, José Manuel; Vicente, Joaquín

    2016-01-14

    Bovine viral diarrhea virus (BVDV) is a pestivirus that affects cattle production worldwide and that can infect other ungulates such as cervids and even wild boar (Sus scrofa). It is believed that domestic livestock can become infected through contact with wild animals, though it is known that infection can spread among wild animals in the absence of contact with livestock. Little is known about the sharing of BVDV infection between wild and domestic animals in the same habitat, which is important for designing eradication campaigns and preventing outbreaks, especially on hunting estates with high animal densities. We assessed the sharing of BVDV infections among hunted red deer, wild boar and cattle in south-central Spain. Sampled red deer (Cervus elaphus; n = 267) and wild boar (n = 52) were located on 19 hunting estates, and cattle (n = 180) were located on 18 nearby farms. We used ELISA kits for the serological screening, Taqman RT-PCR assay for the virus determination, and subsequent phylogenetic analysis for 17 RT-PCR positive sample amplicons. Fifty-two red deer (19.5%) and 82 cattle (45.6%) samples tested positive by ELISA. A high apparent prevalence (22.47%) was obtained for red deer, while only five cattle farms tested positive by RT-PCR. Conversely, no wild boar tested positive by both ELISA or RT-PCR. Eleven red deer (4.1%) tested positive by both ELISA and RT-PCR; these animals may have been sampled during the last phase of viremia, or they may represent previously exposed individuals infected by a different BVDV strain. The amplicons shared 92.7-100% identity and fell within the BVDV subgroup 1b, although nine of these (from four red deer and five cattle pools) formed a separate branch. This suggests that there might be a common BVDV infecting both cattle and red deer. Higher red deer abundance was significantly associated with greater risk that extensively raised cattle would test positive for BVDV by ELISA. Our findings suggest that BVDV

  10. Assessing protein oxidation by inorganic nanoparticles with enzyme-linked immunosorbent assay (ELISA).

    PubMed

    Sun, Wenjie; Luna-Velasco, Antonia; Sierra-Alvarez, Reyes; Field, Jim A

    2013-03-01

    Growth in the nanotechnology industry is leading to increased production of engineered nanoparticles (NPs). This has given rise to concerns about the potential adverse and toxic effects to biological system and the environment. An important mechanism of NP toxicity is oxidative stress caused by the formation of reactive oxygen species (ROS) or via direct oxidation of biomolecules. In this study, a protein oxidation assay was developed as an indicator of biomolecule oxidation by NPs. The oxidation of the protein, bovine serum albumin (BSA) was evaluated with an enzyme-linked immunosorbent assay (ELISA) to measure the protein carbonyl derivatives formed from protein oxidation. The results showed that some NPs such as Cu(0), CuO, Mn(2)O(3), and Fe(0) caused oxidation of BSA; whereas, many of the other NPs tested were not reactive or very slowly reactive with BSA. The mechanisms involved in the oxidation of BSA protein by the reactive NPs could be attributed to the combined effects of ROS-dependent and direct protein oxidation mechanisms. The ELISA assay is a promising method for the assessment of protein oxidation by NPs, which can provide insights on NP toxicity mechanisms. Copyright © 2012 Wiley Periodicals, Inc.

  11. Bovine Tuberculosis and Brucellosis in Cattle and African Buffalo in the Limpopo National Park, Mozambique.

    PubMed

    Tanner, M; Inlameia, O; Michel, A; Maxlhuza, G; Pondja, A; Fafetine, J; Macucule, B; Zacarias, M; Manguele, J; Moiane, I C; Marranangumbe, A S; Mulandane, F; Schönfeld, C; Moser, I; van Helden, P; Machado, A

    2015-12-01

    Bovine tuberculosis (BTB) and brucellosis are prevalent in buffaloes of the Kruger National Park (KNP, South Africa). Both diseases were considered to have no or a very low prevalence in wildlife and livestock in and around the Limpopo National Park (LNP, Mozambique). The same applies for tuberculosis in Gonarezhou National Park (GNP, Zimbabwe), but just recently, BTB was detected in buffaloes in the GNP and fears arose that the disease might also spread to the LNP as a result of the partial removal of the fences between the three parks to form the Great Limpopo Transfrontier Park. To assess the status of both diseases in and around LNP, 62 buffaloes were tested for bovine tuberculosis (BTB) and bovine brucellosis. The percentage of positive BTB reactors in buffalo was 8.06% using BovidTB Stat-Pak® and 0% with BOVIGAM® IFN-γ test and IDEXX ELISA. The brucellosis seroprevalence in buffalo was found to be 17.72% and 27.42% using Rose Bengal Test (RBT) and ELISA, respectively. In addition, 2445 cattle in and around the LNP were examined for BTB using the single intradermal cervical comparative tuberculin test (SICCT), and an apparent prevalence of 0.98% was found with no significant difference inside (0.5%) and outside (1.3%) the park. This is the first published report on the presence of positive reactors to BTB and bovine brucellosis in buffalo and cattle in and outside the LNP. Monitoring the wildlife-livestock-human interface of zoonotic high-impact diseases such as BTB and brucellosis is of outmost importance for the successful implementation and management of any transfrontier park that aims to improve the livelihoods of the local communities. © 2014 Blackwell Verlag GmbH.

  12. Seroprevalence and factors associated with bovine viral diarrhea virus (BVDV) infection in dairy cattle in three milksheds in Ethiopia.

    PubMed

    Aragaw, Kassaye; Sibhat, Berhanu; Ayelet, Gelagay; Skjerve, Eystein; Gebremedhin, Endrias Z; Asmare, Kassahun

    2018-05-31

    This work was conducted to estimate the seroprevalence, to identify potential factors that influence seroprevalence of bovine viral diarrhea virus (BVDV), and to investigate the association between BVDV serostatus and occurrence of reproductive disorders in dairy cattle in three milksheds in Ethiopia. A total of 1379 serum samples were obtained from cattle randomly selected from 149 herds from three milksheds representing central, southern, and western Ethiopia. Sera samples were examined for bovine viral diarrhea virus (BVDV) antibodies using commercial competitive enzyme-linked immunosorbent assay (ELISA) kit. Logistic regression analysis was employed to investigate associations between risk factors and the risk of BVDV seroprevalence, and BVDV serostatus and reproductive disorders. Seroreaction to BVDV antigens was detected in 32.6% of the 1379 cattle and 69.8% of the 149 herds sampled. Factors associated with BVDV seroplevalence were age, breed, and herd size (P < 0.05). Adult cattle ≥ 18 months old had 2.1 (95% CI 1.5, 3.1) times the odds of BVDV seroreaction than younger cattle. Holstein-Friesian (HF) local crosses (OR = 2.1, 95% CI 1.3, 3.4) and HFs (OR = 1.3, 95% CI 0.9, 1.9) were more likely to be seropositive than Jersey and the odds of seropositivity in cattle in large herds with 11 or more animals were higher (OR = 1.8, 95% CI 1.3, 2.5) than the odds of BVDV seropositivity in smaller herds. Seroprevalence was not associated with geographical region (P > 0.05). Risk of reproductive disorders was not affected by BVDV serostatus, except for repeat breeding (P > 0.05). The present study demonstrated that BVDV has wide distribution in the country being detected in all the 15 conurbations and 69.8% of herds involved in the study.

  13. Polyvalent immunoglobulin binding is an obstacle to accurate measurement of specific antibodies with ELISA despite inclusion of blocking agents.

    PubMed

    Loeffler, David A; Klaver, Andrea C

    2017-11-01

    Specific antibody concentrations are frequently measured in serum (and plasma and intravenous immunoglobulin) samples by enzyme-linked immunosorbent assay (ELISA). The standard negative control involves incubation of buffer alone on antigen-coated wells. The immunoreactivity that develops in antigen-coated wells in which diluted serum has been incubated is assumed to represent specific antibody binding. This approach can result in marked overestimation of specific antibody levels, because serum contains specific polyvalent antibodies which bind, primarily with low affinity, to multiple antigens (including those on ELISA plates) despite the use of blocking agents. Non-denaturing purification of serum IgG, followed by assessment of the antigen binding or antigen-binding affinity of this purified IgG, can reduce but not eliminate the problem of polyvalent antibody binding in indirect ELISAs. Alternatively, polyvalent antibody binding can be estimated by incubating a diluted serum sample on wells coated with an irrelevant protein (such as bovine serum albumin or a scrambled peptide sequence) or buffer alone, then subtracting this reactivity from the sample's binding to wells coated with the antigen of interest. Polyvalent binding of immunoglobulins must be accounted for in order to obtain accurate ELISA measurements of serum, plasma, or intravenous immunoglobulin antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Evaluation of a rabies ELISA as an alternative method to seroneutralisation tests in the context of international trade of domestic carnivores.

    PubMed

    Wasniewski, M; Labbe, A; Tribout, L; Rieder, J; Labadie, A; Schereffer, J L; Cliquet, F

    2014-01-01

    For several years, international movements with pets have greatly increased. Most countries have relaxed their quarantine measures and adopted a scheme combining vaccination of pets against rabies followed by a serological test to check the efficacy of vaccination. This new scheme has been strongly supported by the OIE, WHO and the European Commission to facilitate the free movement of people and pets around the world. Currently, only two reference methods are recognised and prescribed (the FAVN test and the RFFIT) to measure rabies antibody levels in serum samples for international trade. They are reliable and valuable methods of assessing the efficacy of rabies vaccination but they are time-consuming and require well-trained people and specialised laboratory facilities. A few years ago, an ELISA (Platelia™ Rabies II kit ad usum Veterinarium) was developed for domestic carnivores and wildlife. To our knowledge, this ELISA is the only one certified and prescribed by the OIE. Following its marketing, one task of the EURL for rabies serology was to evaluate the performance of laboratories using this new kit. The results revealed that 26% of the participants, which were already approved laboratories for rabies serology, failed the inter-laboratory trial. Such unsatisfactory results have never been observed during any of the previous proficiency tests organised annually since 2000 by the EURL for rabies serology using reference methods. More investigations were undertaken through internal and collaborative studies to assess the performance of this newly marketed ELISA kit. The results of the internal study revealed that even with a specificity of 100%, the sensitivity evaluated on 593 samples of domestic carnivores came to 78.2%. An issue regarding the underestimation of serum titres was also revealed during the study. The results of a collaborative study involving 23 international laboratories reinforced the preliminary conclusions regarding lack of sensitivity

  15. Levitation Kits Demonstrate Superconductivity.

    ERIC Educational Resources Information Center

    Worthy, Ward

    1987-01-01

    Describes the "Project 1-2-3" levitation kit used to demonstrate superconductivity. Summarizes the materials included in the kit. Discusses the effect demonstrated and gives details on how to obtain kits. Gives an overview of the documentation that is included. (CW)

  16. The evaluation of a nucleoprotein ELISA for the detection of equine influenza antibodies and the differentiation of infected from vaccinated horses (DIVA).

    PubMed

    Galvin, Pamela; Gildea, Sarah; Arkins, Sean; Walsh, Cathal; Cullinane, Ann

    2013-12-01

    Antibodies against equine influenza virus (EIV) are traditionally quantified by haemagglutination inhibition (HI) or single radial haemolysis (SRH). To evaluate an ELISA for the detection of antibodies against influenza nucleoprotein in the diagnosis and surveillance of equine influenza (EI). The ELISA was compared with the SRH and HI tests. Serial serum samples from 203 naturally and 14 experimentally infected horses, from 60 weanlings following primary vaccination with five different vaccines (two whole inactivated vaccines, two ISCOM-based subunit vaccines and a recombinant canarypox virus vaccine) and from 44 adult horses following annual booster vaccination with six different vaccines were analysed. Fewer seroconversions were detected in clinical samples by ELISA than by SRH or HI but ELISA was more sensitive than SRH in naïve foals post-experimental infection. The ELISA did not detect the antibody response to vaccination with the recombinant canarypox virus vaccine confirming the usefulness of the combination of this kit and vaccine to differentiate between naturally infected and vaccinated horses, that is, DIVA. No DIVA capacity was evident with the other vaccines. The results suggest that this ELISA is a useful supplementary test for the diagnosis of EI although less sensitive than HI or SRH. It is an appropriate test for EI surveillance in a naïve population and may be combined with the recombinant canarypox virus vaccine but not with other commercially available subunit vaccines, in a DIVA strategy. © 2013 Blackwell Publishing Ltd.

  17. A decrease in ubiquitination and resulting prolonged life-span of KIT underlies the KIT overexpression-mediated imatinib resistance of KIT mutation-driven canine mast cell tumor cells.

    PubMed

    Kobayashi, Masato; Kuroki, Shiori; Kurita, Sena; Miyamoto, Ryo; Tani, Hiroyuki; Tamura, Kyoichi; Bonkobara, Makoto

    2017-10-01

    Overexpression of KIT is one of the mechanisms that contributes to imatinib resistance in KIT mutation-driven tumors. Here, the mechanism underlying this overexpression of KIT was investigated using an imatinib-sensitive canine mast cell tumor (MCT) line CoMS, which has an activating mutation in KIT exon 11. A KIT-overexpressing imatinib-resistant subline, rCoMS1, was generated from CoMS cells by their continuous exposure to increasing concentrations of imatinib. Neither a secondary mutation nor upregulated transcription of KIT was detected in rCoMS1 cells. A decrease in KIT ubiquitination, a prolonged KIT life-span, and KIT overexpression were found in rCoMS1 cells. These events were suppressed by withdrawal of imatinib and were re-induced by re‑treatment with imatinib. These findings suggest that imatinib elicited overexpression of KIT via suppression of its ubiquitination. These results also indicated that imatinib-induced overexpression of KIT in rCoMS1 cells was not a permanently acquired feature but was a reversible response of the cells. Moreover, the pan deubiquitinating enzyme inhibitor PR619 prevented imatinib induction of KIT overexpression, suggesting that the imatinib-induced decrease in KIT ubiquitination could be mediated by upregulation and/or activation of deubiquitinating enzyme(s). It may be possible that a similar mechanism of KIT overexpression underlies the acquisition of imatinib resistance in some human tumors that are driven by KIT mutation.

  18. Performance of ELISA antigens prepared from 8 isolates of porcine reproductive and respiratory syndrome virus with homologous and heterologous antisera.

    PubMed Central

    Cho, H J; Entz, S C; Magar, R; Joo, H S

    1997-01-01

    Porcine reproductive and respiratory syndrome virus (PRRSV) ELISA antigens of high quality were produced using 8 different isolates of PRRSV: the European Lelystad virus (LV), the U.S. MN-1b, 89-46448, 93-44927, and 93-24025B, and the Canadian LHVA-93-3, PA-8 and GH-6 virus isolates. The performance of each of these 8 antigens and a commercial PRRSV antibody test kit (Idexx's HerdChek) were measured against antisera raised in 5 groups of 6 piglets inoculated with either LV, MN-1b, 89-46448, 93-44927, or 93-24025B. Among the 8 isolates, the 89-46448 isolate produced the broadest spectrum of antigen and resulted in earlier detection of antibodies to various North American PRRSV isolates, followed by MN-1b as the 2nd best ELISA antigen for the detection of North American PRRSV antibodies. The GH-6 and PA-8 viral antigens exhibited restricted detection of PRRSV antibodies. The LV and 89-46448 combined antigens produced the best performance for the detection of antibodies against both European and North American antigenic types of PRRSV. Using 173 panel samples collected at 11 to 60 d after intranasal inoculation with 1 of the 5 PRRSV isolates, the sensitivities of the indirect ELISA used were 73.4%, 98.3%, 90.8%, 98.3%, 83.2%, 93.1%, 77.1%, 64.2%, 98.8% and 95.9% for LV, MN-1b, LHVA-93-3, 89-46448, 93-44927, 93-24025B, PA-8, GH-6 antigens, 89-46448-LV combined antigens and Idexx's PRRSV antibody test kit, respectively. All 8 antigens gave negative results with preinfection porcine sera (n = 30); high background or nonspecific reactions were not observed with the antigens. PMID:9342455

  19. Kits in Motion

    ERIC Educational Resources Information Center

    Gee, Maureen

    1975-01-01

    Discusses three kits developed by museums in British Columbia for use in rural classrooms. The science kit on marine biology consists of modules which included specimens, books, audiovisual materials and student activities. (BR)

  20. Evaluation of Five Antibody Detection Tests for Diagnosis of Bovine Paratuberculosis

    PubMed Central

    Collins, Michael T.; Wells, Scott J.; Petrini, Kristine R.; Collins, James E.; Schultz, Ronald D.; Whitlock, Robert H.

    2005-01-01

    Five diagnostic tests based on enzyme-linked immunosorbent assay (ELISA) technology for bovine paratuberculosis were evaluated by using individual serum or milk samples from 359 dairy cattle in seven paratuberculosis-free herds and 2,094 dairy cattle in seven Mycobacterium paratuberculosis-infected dairy herds. Three independent laboratories using three different culture procedures completed fecal cultures for M. paratuberculosis on these cattle and found 417 cows to be shedding M. paratuberculosis in their feces. An animal that was fecal culture positive for M. paratuberculosis by any of the three laboratories was considered a confirmed case of infection. The specificity of three ELISAs (two on serum and one on milk) was ≥99.8%. The specificity of the remaining two ELISAs, both done on serum, was 94.9 and 84.7%. Four of the five ELISAs evaluated produced similar sensitivity in detecting fecal culture-positive cattle (27.8 to 28.9%). Serum ELISA “D” had the lowest specificity (84.7%) and the highest sensitivity (44.5%), but if the cutoff value defining a positive test was changed from 125 to 250% (of the positive control) the sensitivity and specificity, 31.8 and 97.5%, respectively, were comparable to those of the other four assays. If the case definition for M. paratuberculosis infection was based on the culture results of a single laboratory instead of the combined results of three laboratories, ELISA sensitivity estimates were 45.7 to 50.0%. With the exception of ELISA D, assay agreement was high (kappa 0.66 to 0.85) for categorical assay interpretations (positive or negative), but linear regression of quantitative results showed low correlation coefficients (r2 = 0.40 to 0.68) due to the fact that ELISA results for some cows were high in one assay but low in another assay. Likelihood ratio analysis showed a direct relationship between the magnitude of ELISA result and the odds of a cow shedding M. paratuberculosis in its feces. If used judiciously and

  1. First aid kit

    MedlinePlus

    ... this page: //medlineplus.gov/ency/article/001958.htm First aid kit To use the sharing features on this ... ahead, you can create a well-stocked home first aid kit. Keep all of your supplies in one ...

  2. Development of a bead-based multiplexed assay for simultaneous quantification of five bovine cytokines by flow cytometry.

    PubMed

    Rodrigues, Valérie; Baudier, Jean Baptiste; Chantal, Isabelle

    2017-09-01

    Quantifying cytokines is extremely important in studies of host-pathogen interactions. Multiplex assays are commercially available but only for human and mouse cytokines. Here a method for the simultaneous quantification of five important bovine cytokines IFNγ, IL-4, IL-10, IL-12, and TNFα in cell culture supernatants, using flow cytometry was reported. Functional beads from BD Biosciences expressing specific APC intensity were used. Commercially available antibodies against bovine cytokines were covalently coupled to beads as capture antibodies. Fixed recombinant cytokines were revealed with a second monoclonal antibody coupled with biotin, then revealed with streptavidin-PE. This complex was analyzed using a standard flow cytometer. Experiments were performed to check no cross reactions had occurred. The limits of detection ranged between 0.08 and 0.4 ng/ml depending on the cytokine, and the linearity between the lower and higher limits was remarkable (R 2  > 99.8%). Finally, native cytokines from cell culture supernatants were tested. Results were compared using the standard ELISA test and showed that concentrations of native cytokine in cell culture supernatants were comparable with the two methods, with a wider dynamic range using beads and flow cytometry than with ELISA assays. Bovine IFNγ, IL-4, IL-10, IL-12, and TNFα in culture supernatants can be now simultaneously detected in a single assay, using a standard flow cytometer for both basic and high-throughput analyses. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.

  3. A comparison of two ELISAs for the detection of antibodies to bovine leucosis virus in bulk-milk.

    PubMed

    Ridge, S E; Galvin, J W

    2005-07-01

    To estimate the sensitivity, specificity and detection limits for two bulk-milk enzyme-linked immunosorbent assays, the Svanovir BLV-gp51-Ab and the Lactelisa BLV Ab Bi indirect tank 250, for the detection of antibody to bovine leucosis virus in milk. Milk samples from 27 cows known to have enzootic bovine leucosis (EBL) were serially diluted with milk from a herd known to be free from the disease. The dilution at which antibodies could no longer be detected by each test was determined. A total of 1959 bulk-milk samples submitted to a laboratory for the Victorian (EBL) eradication program were tested with both the Svanovir and the Lactelisa assays. A Bayesian approach was used to calculate maximum-likelihood estimates of test sensitivity and specificity. An additional 660 bulk-milk samples were tested with both the Svanovir and the Lactelisa assays. Herds that had positive results on either or both of the assays were subjected to blood or milk testing of individual cattle. The dilution of milk at which the Svanovir assay failed to detect enzootic bovine leucosis antibody in half of the samples was 1 in 40, whereas the comparable value for the Lactelisa was 1 in 200. Computer modeling of the operating characteristics of the Svanovir assay indicated that the sensitivity of that assay would be considerably lower than that for the Lactelisa, and the specificity was estimated to be higher. Evaluation of the assays using 660 bulk-milk samples showed that the Lactelisa assay detected four infected herds that were not detected by the Svanovir test. No false positive results were recorded for either assay. Use of the Lactelisa assay in the Victorian EBL eradication program will enhance disease detection and eradication, but may also result in an increased frequency of false positive bulk-milk test results.

  4. Short communication: Genetic correlation of bovine leukosis incidence with somatic cell score and milk yield in a US Holstein population.

    PubMed

    Abdalla, E A; Weigel, K A; Byrem, T M; Rosa, G J M

    2016-03-01

    Bovine leukosis (BL) is a retroviral disease caused by the bovine leukosis virus (BLV), which affects only cattle. Dairy cows positive for BL produce less milk and have more days open than cows negative for BL. In addition, the virus also affects the immune system and causes weaker response to vaccines. Heritability estimates of BL incidence have been reported for Jersey and Holstein populations at about 0.08, indicating an important genetic component that can potentially be exploited to reduce the prevalence of the disease. However, before BL is used in selection programs, it is important to study its genetic associations with other economically important traits such that correlated responses to selection can be predicted. Hence, this study aimed to estimate the genetic correlations of BL with milk yield (MY) and with somatic cell score (SCS). Data of a commercial assay (ELISA) used to detect BLV antibodies in milk samples were obtained from Antel BioSystems (Lansing, MI). The data included continuous milk ELISA scores and binary milk ELISA results for 11,554 cows from 112 dairy herds across 16 US states. Continuous and binary milk ELISA were analyzed with linear and threshold models, respectively, together with MY and SCS using multitrait animal models. Genetic correlations (posterior means ± standard deviations) between BL incidence and MY were 0.17 ± 0.077 and 0.14 ± 0.076 using ELISA scores and results, respectively; with SCS, such estimates were 0.20 ± 0.081 and 0.17 ± 0.079, respectively. In summary, the results indicate that selection for higher MY may lead to increased BLV prevalence in dairy herds, but that the inclusion of BL (or SCS as an indicator trait) in selection indexes may help attenuate this problem. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  5. Comparison of recombinant cathepsins L1, L2, and L5 as ELISA targets for serodiagnosis of bovine and ovine fascioliasis.

    PubMed

    Martínez-Sernández, Victoria; Perteguer, María J; Hernández-González, Ana; Mezo, Mercedes; González-Warleta, Marta; Orbegozo-Medina, Ricardo A; Romarís, Fernanda; Paniagua, Esperanza; Gárate, Teresa; Ubeira, Florencio M

    2018-05-01

    Infections caused by Fasciola hepatica are of great importance in the veterinary field, as they cause important economic losses to livestock producers. Serodiagnostic methods, typically ELISA (with either native or recombinant antigens), are often used for early diagnosis. The use of native antigens, as in the MM3-SERO ELISA (commercialized as BIO K 211, BIO-X Diagnostics), continues to be beneficial in terms of sensitivity and specificity; however, there is interest in developing ELISA tests based on recombinant antigens to avoid the need to culture parasites. Of the antigens secreted by adult flukes, recombinant procathepsin L1 (rFhpCL1) is the most commonly tested in ELISA to date. However, although adult flukes produce three different clades of CLs (FhCL1, FhCL2, and FhCL5), to our knowledge, the diagnostic value of recombinant FhCL2 and FhCL5 has not yet been investigated. In the present study, we developed and tested three indirect ELISAs using rFhpCL1, rFhpCL2, and rFhpCL5 and evaluated their recognition by sera from sheep and cattle naturally infected with F. hepatica. Although the overall antibody response to these three rFhpCLs was similar, some animals displayed preferential recognition for particular rFhpCLs. Moreover, for cattle sera, the highest sensitivity was obtained using rFhpCL2 (97%), being equal for both rFhpCL1 and rFhpCL5 (87.9%), after adjusting cut-offs for maximum specificity. By contrast, for sheep sera, the sensitivity was 100% for the three rFhpCLs. Finally, the presence of truncated and/or partially unfolded molecules in antigen preparations is postulated as a possible source of cross-reactivity.

  6. Creation of learning kits

    NASA Technical Reports Server (NTRS)

    Stow, D. A.; Estes, J. E.; Mertz, F. C.

    1981-01-01

    A learning kit is an essential part of any remote sensing workshop, course, or in-house training program to provide the "hands-on" experience of working with remotely sensed imagery. This is the objective of laboratory and field exercises as well as the reason behind the production of imagery/map kits. The way in which these learning kits (containing conventional remotely sensed and collateral data products) are put together is described and some concerns that influence the creation of learning kits are discussed. These include budgetary constraints, number of imagery types, and number of collateral data types.

  7. A two-site ELISA can quantify upregulation of SMN protein by drugs for spinal muscular atrophy.

    PubMed

    Nguyen thi Man; Humphrey, E; Lam, L T; Fuller, H R; Lynch, T A; Sewry, C A; Goodwin, P R; Mackenzie, A E; Morris, G E

    2008-11-25

    Spinal muscular atrophy (SMA) is an autosomal recessive disorder characterized by loss of lower motor neurons during early or postnatal development. Severity is variable and is inversely related to the levels of survival of motor neurons (SMN) protein. The aim of this study was to produce a two-site ELISA capable of measuring both the low, basal levels of SMN protein in cell cultures from patients with severe SMA and small increases in these levels after treatment of cells with drugs. A monoclonal antibody against recombinant SMN, MANSMA1, was selected for capture of SMN onto microtiter plates. A selected rabbit antiserum against refolded recombinant SMN was used for detection of the captured SMN. The ratio of SMN levels in control fibroblasts to levels in SMA fibroblasts was greater than 3.0, consistent with Western blot data. The limit of detection was 0.13 ng/mL and SMN could be measured in human NT-2 neuronal precursor cells grown in 96-well culture plates (3 x 10(4) cells per well). Increases in SMN levels of 50% were demonstrable by ELISA after 24 hours treatment of 10(5) SMA fibroblasts with valproate or phenylbutyrate. A rapid and specific two-site, 96-well ELISA assay, available in kit format, can now quantify the effects of drugs on survival of motor neurons protein levels in cell cultures.

  8. Comparison of R5 and G12 Antibody-Based ELISA Used for the Determination of the Gluten Content in Official Food Samples

    PubMed Central

    Hochegger, Rupert; Mayer, Walter; Prochaska, Manuela

    2015-01-01

    Celiac Disease (CD) is one of the most common food intolerances. It comes along with serious damage of the mucosa in the small intestine and is caused by the storage proteins—termed “gluten”—of wheat, rye, barley and possibly oats. Sensitive individuals need to stick to a strict gluten-free diet. The gluten level in food products labeled as “gluten-free”, must not exceed 20 mg/kg. It is obvious that effective test methods are needed to accurately determine the gluten concentration in foods. The determination of the presence of gluten in foodstuffs is mainly done by means of an immunochemical method called ELISA (enzyme-linked immunosorbent assay). To check the suitability of a G12 antibody-based gluten detection kit for its use in official control systems a number of routine samples were tested in parallel with two different test kits, as would be done in a routine lab. The determination of the gluten content was performed on samples entering the official laboratory including samples from official control plans, commercially available and private samples to request gluten-free labels. The results obtained with the G12 antibody ELISA assay were comparable to the official R5 method. A validation of the two different methods was not part of this study. PMID:28231228

  9. Development of a Competitive Enzyme-Linked Immunosorbent Assay for Detection of Antibodies against the 3B Protein of Foot-and-Mouth Disease Virus

    PubMed Central

    Yang, Ming; Parida, Satya; Salo, Tim; Hole, Kate; Velazquez-Salinas, Lauro

    2015-01-01

    Foot-and-mouth disease (FMD) is one of the most highly contagious and economically devastating diseases, and it severely constrains the international trade of animals. Vaccination against FMD is a key element in the control of FMD. However, vaccination of susceptible animals raises critical issues, such as the differentiation of infected animals from vaccinated animals. The current study developed a reliable and rapid test to detect antibodies against the conserved, nonstructural proteins (NSPs) of the FMD virus (FMDV) to distinguish infected animals from vaccinated animals. A monoclonal antibody (MAb) against the FMDV NSP 3B was produced. A competitive enzyme-linked immunosorbent assay (cELISA) for FMDV/NSP antibody detection was developed using a recombinant 3ABC protein as the antigen and the 3B-specific MAb. Sera collected from naive, FMDV experimentally infected, vaccinated carrier, and noncarrier animals were tested using the 3B cELISA. The diagnostic specificity was 99.4% for naive animals (cattle, pigs, and sheep) and 99.7% for vaccinated noncarrier animals. The diagnostic sensitivity was 100% for experimentally inoculated animals and 64% for vaccinated carrier animals. The performance of this 3B cELISA was compared to that of four commercial ELISA kits using a panel of serum samples established by the World Reference Laboratory for FMD at The Pirbright Institute, Pirbright, United Kingdom. The diagnostic sensitivity of the 3B cELISA for the panel of FMDV/NSP-positive bovine serum samples was 94%, which was comparable to or better than that of the commercially available NSP antibody detection kits. This 3B cELISA is a simple, reliable test to detect antibodies against FMDV nonstructural proteins. PMID:25651918

  10. A novel sandwich enzyme-linked immunosorbent assay with covalently bound monoclonal antibody and gold probe for sensitive and rapid detection of bovine β-lactoglobulin.

    PubMed

    He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing

    2018-06-01

    Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3  ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.

  11. Development of a nanogold slot blot inhibition assay for the detection of antibodies against bovine herpesvirus type 1.

    PubMed

    Japolla, Greice; Cunha-Junior, Jair Pereira; Pajuaba, Ana Claudia Arantes Marquez; Taketomi, Ernesto Akio; Bührer-Sékula, Samira; Bataus, Luiz Artur Mendes; de Souza, Guilherme Rocha Lino

    2018-06-01

    Bovine herpesvirus type 1 (BoHV-1) is recognized as an important pathogen causing respiratory, reproductive, and neurological disorders in cattle and is associated with economic losses to animal industry. Accurate diagnostic methods are needed for prevention of disease transmission. While the virus neutralization test is considered the gold standard method, it requires maintenance of the virus and cell cultures, which is time consuming and expensive. Serological techniques such as enzyme-linked immunosorbent assay (ELISA) are widely applied, as these are easy to perform and provide quick results. In the present study, a nanogold slot blot inhibition assay was developed for the serological diagnosis of BoHV-1 and compared with standard ELISA and horseradish peroxidase (HRP) slot blot assays. Of 42 serum samples tested by ELISA, 32 (76.2%) were positive and 10 (23.8%), were negative. The sensitivity and specificity of the nanogold slot blot inhibition assay was similar to that observed for ELISA and HRP slot blot assays, and a strong correlation was observed between the tests. Thus, the nanogold slot blot inhibition assay may serve as an efficient and rapid alternative to ELISA in settings, where plate-reading equipment is lacking.

  12. Synthesis and processing of ELISA polymer substitute: The influence of surface chemistry and morphology on detection sensitivity

    NASA Astrophysics Data System (ADS)

    Hosseini, Samira; Ibrahim, Fatimah; Djordjevic, Ivan; Rothan, Hussin A.; Yusof, Rohana; van der Marel, Cees; Koole, Leo H.

    2014-10-01

    Despite the known drawbacks of enzyme-linked immunosorbent assay (ELISA), one of the deficiencies that have relatively been ignored is the performance of ELISA substrate itself. Polystyrene (PS), as the cost effective material of choice for mass production of ELISA well-plates, has shown obvious lacks of suitable physical and chemical properties for protein attachment. The general concept of this work was to develop a potential substrate that can be suggested as a material of choice for production of a new generation of ELISA analytical kits. Spin-coated thin films of polymethyl methacrylate-co-methacrylic acid (PMMA-co-MAA) on silicon surfaces were designed and processed for detection of dengue virus. Coated surfaces of different molar ratios have been investigated as carboxyl-functionalized layers for obtaining platform for biomolecule immobilization with high level of protein activity. To improve the sensitivity of detection, we have used amine functional "spacers", hexamethylenediamine (HMDA) and polyethyleneimine (PEI), which were covalently bonded to the surfaces of PMMA-co-MAA coatings. Results demonstrate that the variation of surface concentration of carboxyl groups of PMMA-co-MAA can be used to control the amine surface concentration after carbodiimide coupling with HMDA and PEI spacers. The presence of amine spacers increases hydrophilicity of the coatings and significantly impacts the polymer surface morphology. In particular, protein immobilization via amine-bearing spacers has been achieved in two effective steps: (1) carbodiimide bonding between amine spacer molecules and PMMA-co-MAA polymer coatings; and (2) covalent immobilization of antibody via glutaraldehyde reaction with amine groups from amine-treated surfaces. The application of PEI spacer in comparison to HMDA has shown much higher intensity of detection signal in ELISA experiment, indicating better immobilization efficiency and preservation of antibody activity upon attachment to the

  13. Environmental Technology Verification Report for Abraxis Ecologenia® 17β-Estradiol (E2) Microplate Enzyme-Linked Immunosorbent Assay (ELISA) Test Kits

    EPA Science Inventory

    This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...

  14. Acupuncture Ameliorates Postoperative Ileus via IL-6-miR-19a-KIT Axis to Protect Interstitial Cells of Cajal.

    PubMed

    Deng, Jingjing; Yang, Shu; Yuan, Qing; Chen, Yuzhong; Li, Dandan; Sun, Haimei; Tan, Xinghua; Zhang, Fuchun; Zhou, Deshan

    2017-01-01

    Acupuncture is a therapy effective in treating postoperative ileus (POI); its underlying mechanisms remain unclear. MicroRNAs (miRNAs) participate in inflammation and injury to the interstitial cells of Cajal (ICCs), both of which are considered to be contributors to POI. C-kit, encoding KIT, a specific marker of ICCs, is predicted to be targeted by miR-19a, an inflammation-related miRNA. Therefore, we investigated a possible link between inflammation, miR-19a, and ICCs in POI, as well as the mechanism by which these factors are affected by acupuncture. The effects of acupuncture on POI were assessed in patients after colorectal resection and in colocolic anastomosis mice. Immunofluorescence staining demonstrated that KIT[Formula: see text]/ano1[Formula: see text] ICCs dramatically decreased around the colonic incision in mice, which was negatively correlated with the pronounced increase in macrophage. However, this decrease was not due to apoptosis. IL-6R was expressed in ICCs, and IL-6 level was significantly increased, as measured by ELISA, in accompaniment with high miR-19a expression. The increase in IL-6 and miR-19a levels was negatively correlated with the decrease in KIT[Formula: see text]/ano1[Formula: see text] ICCs. A luciferase reporter assay demonstrated that miR-19a directly targeted C-kit, indicating that miR-19a caused ICC damage. Interestingly, acupuncture inhibited macrophage activation, IL-6 release, and miR-19a upregulation, while promoting KIT and ano1 restoration in ICCs. High serum miR-19a level in patients after colorectal resection was also reduced by acupuncture. Conclusively, the IL-6 released by macrophages during gastrointestinal surgery upregulated miR-19a, which downregulated KIT in ICCs and finally resulted in POI. Acupuncture can interfere with the "IL-6-miR-19a-KIT" axis, suggesting that it may be a therapeutic mechanism that works against POI.

  15. Seroprevalence of major bovine-associated zoonotic infectious diseases in the Lao People's Democratic Republic.

    PubMed

    Vongxay, Khamphouth; Conlan, James V; Khounsy, Syseng; Dorny, Pierre; Fenwick, Stanley; Thompson, R C Andrew; Blacksell, Stuart D

    2012-10-01

    Bovine-associated zoonotic infectious diseases pose a significant threat to human health in the Lao People's Democratic Republic (Lao PDR). In all, 905 cattle and buffalo serum samples collected in northern Lao PDR in 2006 were used to determine seroprevalence of five major bovine zoonotic infectious diseases that included Taenia saginata cysticercosis, bovine tuberculosis, Q-fever, bovine brucellosis, and bovine leptospirosis. Five enzyme-linked immunosorbent assays (ELISAs) were used to test for the presence of antibodies to the diseases, except Taenia saginata, for which we tested for the presence of Taenia metacestode circulating antigens. The overall highest prevalence was for T. saginata (46.4%), with lower prevalence for Q-fever (4%), leptospirosis (3%), tuberculosis (1%), and brucellosis (0.2%). Although there were no significant differences in the proportion of seroprevalence between sex and age of the animals sampled, there were significant differences between the provincial distributions. Further studies are required to determine the seroprevalence of these infections in other locations in Lao PDR, as well as other animal species including humans, in order to develop effective prevention and control strategies. This is the first study to investigate the prevalence of bovine zoonotic infectious agents in the Lao PDR. Positivity was demonstrated for all diseases investigated, with the highest prevalence for T. saginata antigen and Coxiella burnetti antibodies. For T. saginata, there were significant differences in the provincial distribution. Approximately 16% seroprevalence of Coxiella burnetti was noted in Xayabuly Province; however, there are no clear reasons why this was the case, and further studies are required to determine risk factors associated with this observation.

  16. Periurban outbreaks of bovine calf scours in Northern India caused by Cryptosporidium in association with other enteropathogens.

    PubMed

    Brar, A P S; Sood, N K; Kaur, P; Singla, L D; Sandhu, B S; Gupta, K; Narang, D; Singh, C K; Chandra, M

    2017-10-01

    Bovine calf scours reported to be caused by multiple aetiologies resulting in heavy mortality in unweaned calves and huge economic loss to the dairy farmers. Among these, cryptosporidiosis is an emerging waterborne zoonoses and one of the important causes of neonatal calf diarrhoea. Poor immune response coupled with primary cryptosporidial infections predispose neonatal calves to multiple secondary infections resulting in their deaths. In the present study, faecal samples from 100 diarrhoeic calves randomly picked up out of 17 outbreaks of bovine calf diarrhoea in periurban Ludhiana, Punjab in Northern India were subjected to conventional (microscopy, modified Zeihl-Neelsen (mZN) staining) and immunological and molecular techniques (faecal antigen capture ELISA and PCR) for detection of primary Cryptosporidium parvum infection as well as other frequently reported concurrent pathogens, viz. rotavirus and coronavirus, Salmonella spp., Escherichia coli, Clostridium perfringens and Eimeria spp. The faecal antigen capture ELISA and PCR revealed 35% prevalence of C. parvum in contrast to 25% by mZN staining with a relatively higher prevalence (66·7%) in younger (8-14-day-old) calves. The detection rate of the other enteropathogens associated with C. parvum was 45·71% for C. perfringens followed by Salmonella spp (40·0%), rotavirus (36·0%), coronavirus (16·0%), E. coli (12·0%) and Eimeria spp (4·0%) The sensitivity for detection of C. parvum by ELISA and mZN staining in comparison to PCR was 97·14% and 72·72%, respectively. An important finding of the study was that C. parvum alone was found in only 10% of the diarrhoeic faecal samples, whereas, majority of the samples (90%) showed mixed infections ranging from a combination of two to five agents. This is the first documentary proof of C. parvum and associated pathogens responsible for severe periurban outbreaks of bovine calf diarrhoea culminating in heavy mortality from Northern India.

  17. Disruption of c-Kit Signaling in Kit(W-sh/W-sh) Growing Mice Increases Bone Turnover.

    PubMed

    Lotinun, Sutada; Krishnamra, Nateetip

    2016-08-16

    c-Kit tyrosine kinase receptor has been identified as a regulator of bone homeostasis. The c-Kit loss-of-function mutations in WBB6F1/J-Kit(W/W-v) mice result in low bone mass. However, these mice are sterile and it is unclear whether the observed skeletal phenotype is secondary to a sex hormone deficiency. In contrast, C57BL/6J-Kit(W-sh)/(W-sh) (W(sh)/W(sh)) mice, which carry an inversion mutation affecting the transcriptional regulatory elements of the c-Kit gene, are fertile. Here, we showed that W(sh)/W(sh) mice exhibited osteopenia with elevated bone resorption and bone formation at 6- and 9-week-old. The c-Kit W(sh) mutation increased osteoclast differentiation, the number of committed osteoprogenitors, alkaline phosphatase activity and mineralization. c-Kit was expressed in both osteoclasts and osteoblasts, and c-Kit expression was decreased in W(sh)/W(sh)osteoclasts, but not osteoblasts, suggesting an indirect effect of c-Kit on bone formation. Furthermore, the osteoclast-derived coupling factor Wnt10b mRNA was increased in W(sh)/W(sh) osteoclasts. Conditioned medium from W(sh)/W(sh) osteoclasts had elevated Wnt10b protein levels and induced increased alkaline phosphatase activity and mineralization in osteoblast cultures. Antagonizing Wnt10b signaling with DKK1 or Wnt10b antibody inhibited these effects. Our data suggest that c-Kit negatively regulates bone turnover, and disrupted c-Kit signaling couples increased bone resorption with bone formation through osteoclast-derived Wnt 10 b.

  18. [Prokaryotic expression of the major antigenic domain of equine arteritis virus GL protein and the establishment of putative indirect ELISA assay].

    PubMed

    Liang, Cheng-Zhu; Cao, Rui-Bing; Wei, Jian-Chao; Zhu, Lai-Hua; Chen, Pu-Yan

    2006-06-01

    According to the antigenic analysis of equine arteritis virus (EAV) GL protein, one pair of primers were designed, with which the gene fragment coding the high antigenic domain of EAV GL protein was amplified from the EAV genome. The cloned gene was digested with BamH I and Xho I and then inserted into pET-32a and resulted pET-GL1. The pET-GL1 was transformed into the host cell BL21(DE3) and the expression was optimized including cultivation temperature and concentration of IPTG. The aim protein was highly expressed and the obtained recombinant protein manifested well reactiongenicity as was confirmed by Western blot. The recombinant GL1 protein was purified by the means of His * Bind resin protein purification procedure. Then an indirect ELISA was established to detect antibody against EAV with the purified GL1 protein as the coating antigen. The result showed that the optimal concentration of coated antigen was 9.65 microg/mL and the optimal dilution of serum was 1:80. The positive criterion of this ELISA assay is OD (the tested serum) > 0.4 and OD (the tested serum) /OD (the negative serum) > 2.0. The iGL-ELISA was evaluated versus micro-virus neutralization test. The ELISA was performed on 900 sera from which were preserved by this lab during horse entry/exit inspection, the agreement (94.1%) of these test were considered suitable for individual serological detection. In another test which 180 sera samples were detected by iGL-ELISA and INGEZIM ELISA kit respectively. The agreement ratio between the two methods is 95.6%.

  19. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Unknown

    2001-05-31

    Western Research Institute (WRI) is commercializing Diesel Dog Portable Soil Test Kits for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to the technology by taking the method through the American Societymore » for Testing and Materials (ASTM) approval and validation processes. The method is designated ASTM Method D-5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In FY 99, twenty-five preproduction kits were successfully constructed in cooperation with CF Electronics, Inc., of Laramie, Wyoming. The kit components work well and the kits are fully operational. In the calendar year 2000, kits were provided to the following entities who agreed to participate as FY 99 and FY 00 JSR (Jointly Sponsored Research) cosponsors and use the kits as opportunities arose for field site work: Wyoming Department of Environmental Quality (DEQ) (3 units), F.E. Warren Air Force Base, Gradient Corporation, The Johnson Company (2 units), IT Corporation (2 units), TRC Environmental Corporation, Stone Environmental, ENSR, Action Environmental, Laco Associates, Barenco, Brown and Caldwell, Dames and Moore Lebron LLP, Phillips Petroleum, GeoSyntek, and the State of New Mexico. By early 2001, ten kits had been returned to WRI following the six-month evaluation period. On return, the components of all ten kits were fully functional. The kits were upgraded with circuit modifications, new polyethylene foam inserts, and updated instruction manuals.« less

  20. Evaluation of nine immunoassay kits (enzyme immunoassay and direct fluorescence) for detection of Giardia lamblia and Cryptosporidium parvum in human fecal specimens.

    PubMed Central

    Garcia, L S; Shimizu, R Y

    1997-01-01

    It is well known that Giardia lamblia and Cryptosporidium parvum can cause severe symptoms in humans, particularly those who are immunologically compromised. Immunoassay procedures offer both increased sensitivity and specificity compared to conventional staining methods. These reagents are also helpful when screening large numbers of patients, particularly in an outbreak situation or when screening patients with minimal symptoms. The data obtained by using 9 diagnostic kits were compared: direct fluorescent-antibody assay (DFA) kits (TechLab Giardia/Crypto IF kit, TechLab Crypto IF kit, and Meridian Merifluor Cryptosporidium/Giardia) and enzyme immunoassay (EIA) kits (Alexon ProSpecT Giardia EZ Microplate Assay, Alexon ProSpecT Cryptosporidium Microplate Assay, Cambridge Giardia lamblia Antigen Microwell ELISA, Meridian Premier Giardia lamblia, Meridian Premier Cryptosporidium, TechLab Giardia CELISA, Trend Giardia lamblia EIA). The test with the Meridian Merifluor Cryptosporidium/Giardia kit was used as the reference method. In various combinations, 60 specimens positive for Giardia, 60 specimens positive for Cryptosporidium, 40 specimens positive for a Giardia-Cryptosporidium mix, and 50 negative fecal specimens were tested. Different species (nine protozoa, three coccidia, one microsporidium, five nematodes, three cestodes, and one trematode) were included in the negative specimens. The sensitivity of EIA for Giardia ranged from 94% (Alexon) to 99% (Trend and Cambridge); the specificity was 100% with all EIA kits tested. The sensitivity of EIA for Cryptosporidium ranged from 98% (Alexon) to 99% (Meridian Premier); specificities were 100%. All DFA results were in agreement, with 100% sensitivity and specificity; however, the TechLab reagents resulted in fluorescence intensity that was generally one level below that seen with the reagents used in the reference method. In addition to sensitivity and specificity, factors such as cost, simplicity, ease of

  1. Identification and verification of the anabolic steroid boldenone in equine blood and urine by HPLC/ELISA.

    PubMed

    Hagedorn, H W; Schulz, R; Jaeschke, G

    1994-01-01

    An enzyme linked immunosorbent assay (ELISA) was developed to detect the anabolic steroid boldenone in equine blood and urine. The polyclonal antiserum was raised in rabbits, employing boldenone-17-hemisuccinate-bovine serum albumin as antigen. Boldenone-17-hemisuccinate-horseradish peroxidase served as enzyme conjugate. Sensitivity of the assay was 26.0 +/- 3.0 pg/well. Among the endogenous steroids tested only progesterone and testosterone exhibited moderate cross-reactivities, 3.4 and 2.5%, respectively. These cross-reactivities are of no importance for the boldenone assay. For the reduction of background levels, screening for boldenone of equine serum was performed after extraction. Urine samples were determined directly after dilution, omitting hydrolysis of boldenone conjugates. Positive screening results were confirmed by means of two independent HPLC systems combined with off-line detection, employing the boldenone ELISA. Methandienone served as internal standard to ascertain retention factors. In horses treated with boldenone-17-undecylenate the presence of boldenone in serum was confirmed up to 28 days and in unhydrolyzed urine up to 56 days post applicationem.

  2. Iodine-Mediated Etching of Gold Nanorods for Plasmonic ELISA Based on Colorimetric Detection of Alkaline Phosphatase.

    PubMed

    Zhang, Zhiyang; Chen, Zhaopeng; Wang, Shasha; Cheng, Fangbin; Chen, Lingxin

    2015-12-23

    Here, we propose a plasmonic enzyme-linked immunosorbent assay (ELISA) based on highly sensitive colorimetric detection of alkaline phosphatase (ALP), which is achieved by iodine-mediated etching of gold nanorods (AuNRs). Once the sandwich-type immunocomplex is formed, the ALP bound on the polystyrene microwells will hydrolyze ascorbic acid 2-phosphate into ascorbic acid. Subsequently, iodate is reduced to iodine, a moderate oxidant, which etches AuNRs from rod to sphere in shape. The shape change of AuNRs leads to a blue-shift of longitudinal localized surface plasmon resonance. As a result, the solution of AuNRs changes from blue to red. Benefiting from the highly sensitive detection of ALP, the proposed plasmonic ELISA has achieved an ultralow detection limit (100 pg/mL) for human immunoglobulin G (IgG). Importantly, the visual detection limit (3.0 ng/mL) allows the rapid differential diagnosis with the naked eye. The further detection of human IgG in fetal bovine serum indicates its applicability to the determination of low abundance protein in complex biological samples.

  3. Evaluation of a commercial ELISA for H5 low pathogenic avian influenza virus antibody detection in duck sera using Bayesian methods.

    PubMed

    Schmitz, Audrey; Le Bras, Marie-Odile; Guillemoto, Carole; Pierre, Isabelle; Rose, Nicolas; Bougeard, Stéphanie; Jestin, Véronique

    2013-10-01

    Following the emergence of highly pathogenic avian influenza (AI), active surveillance of infections due to the H5 and H7 subtypes in poultry has increased and been made compulsory in Europe since 2002, by means of annual serological surveys using the haemagglutination inhibition (HI) test. Domestic anseriforms, particularly ducks and geese, are more frequently infected by H5 low pathogenic AI virus, often subclinically, and represent a threat for other terrestrial poultry. 1783 sera, mainly from ducks, have been used to evaluate and compare a commercial ELISA kit detecting H5 antibodies with the currently recommended HI test. Different approaches to calculating specificity and sensitivity have been used, including the original Bayesian method. Results were similar when data were analyzed at the individual and batch levels, and when using different methods of calculation. However, results showed that H5 ELISA had both a higher sensitivity and a lower specificity than the HI test. Given that sensitivity is the most important factor for a screening test, H5 ELISA could therefore be recommended for AI surveillance, followed in cases of positivity by molecular tests aimed at detecting the virus gene. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Development and evaluation of a truncated recombinant NS3 antigen-based indirect ELISA for detection of pestivirus antibodies in sheep and goats.

    PubMed

    Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya

    2015-01-01

    The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.

  5. Urea, the most abundant component in urine, cross-reacts with a commercial 8-OH-dG ELISA kit and contributes to overestimation of urinary 8-OH-dG.

    PubMed

    Song, Ming-Fen; Li, Yun-Shan; Ootsuyama, Yuko; Kasai, Hiroshi; Kawai, Kazuaki; Ohta, Masanori; Eguchi, Yasumasa; Yamato, Hiroshi; Matsumoto, Yuki; Yoshida, Rie; Ogawa, Yasutaka

    2009-07-01

    Urinary 8-OH-dG is commonly analyzed as a marker of oxidative stress. For its analysis, ELISA and HPLC methods are generally used, although discrepancies in the data obtained by these methods have often been discussed. To clarify this problem, we fractionated human urine by reverse-phase HPLC and assayed each fraction by the ELISA method. In addition to the 8-OH-dG fraction, a positive reaction was observed in the first eluted fraction. The components in this fraction were examined by the ELISA. Urea was found to be the responsible component in this fraction. Urea is present in high concentrations in the urine of mice, rats, and humans, and its level is influenced by many factors. Therefore, certain improvements, such as a correction based on urea content or urease treatment, are required for the accurate analysis of urinary 8-OH-dG by the ELISA method. In addition, performance of the ELISA at 4 degrees C reduced the recognition of urea considerably and improved the 8-OH-dG analysis.

  6. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 1 2010-10-01 2010-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  7. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 1 2012-10-01 2012-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  8. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 1 2011-10-01 2011-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  9. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 1 2013-10-01 2013-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  10. 47 CFR 15.25 - Kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 47 Telecommunication 1 2014-10-01 2014-10-01 false Kits. 15.25 Section 15.25 Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES General § 15.25 Kits. A TV interface device, including a cable system terminal device, which is marketed as a kit shall comply with the...

  11. Comparison of Coxiella burnetii shedding in milk of dairy bovine, caprine, and ovine herds.

    PubMed

    Rodolakis, A; Berri, M; Héchard, C; Caudron, C; Souriau, A; Bodier, C C; Blanchard, B; Camuset, P; Devillechaise, P; Natorp, J C; Vadet, J P; Arricau-Bouvery, N

    2007-12-01

    The shedding of Coxiella burnetii in bovine, caprine, and ovine milk was measured using PCR, in 3 herds for each species, the bulk tank milk samples of which were positive at the time of their selection. Milk samples of 95 cows, 120 goats, and 90 ewes were sampled over 16 wk, as was the bulk tank milk. The shedding of C. burnetii in vaginal mucus and feces was checked at the beginning of the experiment and 2 mo later. The clinical signs in the selected herds as well as the duration and the shedding routes differed among the 3 species. The cows were asymptomatic and shed C. burnetii almost exclusively in milk. In one of the caprine herds, abortions due to C. burnetii were reported. The goats excreted the bacteria mainly in milk. In contrast, the ewes, which came from flocks with abortions due to Q fever (C. burnetii infection), shed the bacteria mostly in feces and in vaginal mucus. This could explain why human outbreaks of Q fever are more often related to ovine flocks than to bovine herds. These excretions did not seem more frequent when the samples were taken close to parturition. The samples were taken from 0 to 421 d after parturition in bovine herds and from 5 to 119 d and 11 to 238 d after parturition in the caprine and ovine herds, respectively. The shedding in milk was sometimes intermittent, and several animals shed the bacteria but were negative by ELISA: 80% of the ewes were seronegative, underscoring the lack of sensitivity of the ELISA tests available for veterinary diagnosis. The detection of antibodies in milk seems more sensitive than it is in serum.

  12. Benchmarking Tool Kit.

    ERIC Educational Resources Information Center

    Canadian Health Libraries Association.

    Nine Canadian health libraries participated in a pilot test of the Benchmarking Tool Kit between January and April, 1998. Although the Tool Kit was designed specifically for health libraries, the content and approach are useful to other types of libraries as well. Used to its full potential, benchmarking can provide a common measuring stick to…

  13. Survival Kit - Food Kit

    NASA Image and Video Library

    1962-10-01

    S62-08743 (1962) --- Food kit used by Mercury astronauts. Some is dehydrated and needs water, other packets are ready to eat. Size is measured relative to a ruler. Included are packets of mushroom soup, orange-grapefruit juice, cocoa beverage, pineapple juice, chicken with gravy, pears, strawberries, beef and vegetables and other assorted food containers. Photo credit: NASA

  14. Survival Kit - Food Kit

    NASA Image and Video Library

    1962-10-01

    S62-08742 (1962) --- Food kit used by Mercury astronauts. Some is dehydrated and needs water, other packets are ready to eat. Size is measured relative to a ruler. Included are packets of mushroom soup, orange-grapefruit juice, cocoa beverage, pineapple juice, chicken with gravy, pears, strawberries, beef and vegetables and other assorted food containers. Photo credit: NASA

  15. Rapid Typing of Transmissible Spongiform Encephalopathy Strains with Differential ELISA

    PubMed Central

    Simon, Stéphanie; Nugier, Jérôme; Morel, Nathalie; Boutal, Hervé; Créminon, Christophe; Benestad, Sylvie L.; Andréoletti, Olivier; Lantier, Frédéric; Bilheude, Jean-Marc; Feyssaguet, Muriel; Biacabe, Anne-Gaëlle; Baron, Thierry

    2008-01-01

    The bovine spongiform encephalopathy (BSE) agent has been transmitted to humans, leading to variant Creutzfeldt-Jakob disease. Sheep and goats can be experimentally infected by BSE and have been potentially exposed to natural BSE; however, whether BSE can be transmitted to small ruminants is not known. Based on the particular biochemical properties of the abnormal prion protein (PrPsc) associated with BSE, and particularly the increased degradation induced by proteinase K in the N terminal part of PrPsc, we have developed a rapid ELISA designed to distinguish BSE from other scrapie strains. This assay clearly discriminates experimental ovine BSE from other scrapie strains and was used to screen 260 transmissible spongiform encephalopathy (TSE)–infected small ruminant samples identified by the French active surveillance network (2002/2003). In this context, this test has helped to identify the first case of natural BSE in a goat and can be used to classify TSE isolates based on the proteinase K sensitivity of PrPsc. PMID:18394279

  16. ELISA: Methods and Protocols

    USDA-ARS?s Scientific Manuscript database

    The antibody is central to the performance of an ELISA providing the basis of analyte selection and detection. It is the interaction of antibody with analyte under defined conditions that dictates the outcome of the ELISA and deviations in those conditions will impact assay performance. The aim of...

  17. A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.

    PubMed

    Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E

    2014-08-27

    Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Adaptation of commercial biomarker kits and proposal for 'drug development kits' to support bioanalysis: call for action.

    PubMed

    Islam, Rafiqul; Kar, Sumit; Islam, Clarinda; Farmen, Raymond

    2018-06-01

    There has been an increased use of commercial kits for biomarker measurement, commensurate with the increased demand for biomarkers in drug development. However, in most cases these kits do not meet the quality attributes for use in regulated environment. The process for adaptation of these kits can be frustrating, time consuming and resource intensive. In addition, a lack of harmonized guidance for the validation of biomarker poses a significant challenge in the adaptation of kits in a regulated environment. The purpose of this perspective is to propose a tiered approach to commercial drug development kits with clearly defined quality attributes and to demonstrate how these kits can be adapted to perform analytical validation in a regulated environment.

  19. Design and characterization of a direct ELISA for the detection and quantification of leucomalachite green

    PubMed Central

    Singh, Gurmit; Koerner, Terence; Gelinas, Jean-Marc; Abbott, Michael; Brady, Beth; Huet, Anne-Catherine; Charlier, Caroline; Delahaut, Philippe; Godefroy, Samuel Benrejeb

    2011-01-01

    Malachite green (MG), a member of the N-methylated triphenylmethane class of dyes, has long been used to control fungal and protozoan infections in fish. MG is easily absorbed by fish during waterborne exposure and is rapidly metabolized into leucomalachite green (LMG), which is known for its long residence time in edible fish tissue. This paper describes the development of an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of LMG in fish tissue. This development includes a simple and versatile method for the conversion of LMG to monodesmethyl-LMG, which is then conjugated to bovine serum albumin (BSA) to produce an immunogenic material. Rabbit polyclonal antibodies are generated against this immunogen, purified and used to develop a direct competitive enzyme-linked immunosorbent assay (ELISA) for the screening and quantification of LMG in fish tissue. The assay performed well, with a limit of detection (LOD) and limit of quantification (LOQ) of 0.1 and 0.3 ng g−1 of fish tissue, respectively. The average extraction efficiency from a matrix of tilapia fillets was approximately 73% and the day-to-day reproducibility for these extractions in the assay was between 5 and 10%. PMID:21623496

  20. Anti-Neospora caninum and anti-Sarcocystis spp. specific antibodies cross-react with Besnoitia besnoiti and influence the serological diagnosis of bovine besnoitiosis.

    PubMed

    García-Lunar, P; Moré, G; Campero, L; Ortega-Mora, L M; Álvarez-García, G

    2015-11-30

    Bovine besnoitiosis control remains a challenge because the disease continues to spread and control relies solely on accurate diagnosis coupled to management measures. However, recent studies have reported that routinely used ELISAs may raise a high number of false-positive results. Herein, cross-reactions between Besnoitia besnoiti antigens and anti-Neospora caninum and/or anti-Sarcocystis spp.-specific antibodies were studied in an in house ELISA since N. caninum and Sarcocystis spp. are closely related parasites, and both infections are highly prevalent in cattle worldwide. The serum panel was composed of the following categories: sera from B. besnoiti-seronegative (n=75) and -seropositive cattle (n=66), B. besnoiti-based-ELISA false-positive reactors (n=96) together with N. caninum (n=36) and Sarcocystis spp. (n=42) -seropositive reference cattle sera. B. besnoiti tachyzoite based western blot (WB) results classified animals as seropositive or seronegative. Sera were analyzed for the detection of anti-N. caninum by WB and ELISA and anti-Sarcocystis spp.-specific antibodies by WB and IFAT. Those samples recognizing a Sarcocystis spp. 18-20 kDa antigenic region and N. caninum 17-18 kDa immunodominant antigen were considered to be Sarcocystis spp. and N. caninum seropositive, respectively. The category of B. besnoiti based-ELISA false-positive reactors showed the highest number of sera with specific anti-Sarcocystis spp. and anti-N. caninum antibodies (74%; 71/96), followed by the N. caninum-seropositive cattle category (52.8%; 19/36). In contrast, few B. besnoiti-seronegative and -seropositive cattle showed antibodies against Sarcocystis spp. and N. caninum (10.7%; 8/75 and 1.5%; 1/66), respectively). This study revealed that B. besnoiti false-positive ELISA results were associated not only with the presence of anti-N. caninum and anti-Sarcocystis spp. antibodies (χ(2): 78.36; p<0.0001; OR: 34.6; CI: 14-88) but also with high antibody levels against them using

  1. [Consistency study of PowerPlex 21 kit and Goldeneye 20A kit and forensic application].

    PubMed

    Ren, He; Liu, Ying; Zhang, Qing-Xia; Jiao, Zhang-Ping

    2014-06-01

    To ensure the consistency of genotype results for PowerPlex 21 kit and Goldeneye 20A kit. The STR loci were amplified in DNA samples from 205 unrelated individuals in Beijing Han population. And consistency of 19 overlap STR loci typing were observed. The genetic polymorphism of D1S1656 locus was obtained. All 19 overlap loci typing showed consistent. The proportion of peak height of heterozygous loci in two kits showed no statistical difference (P > 0.05). The observed heterozygosis of D1S1656 was 0.878. The discrimination power was 0.949. The excluding probability of paternity of triplet was 0.751. The excluding probability of paternity of diploid was 0.506. The polymorphism information content was 0.810. PowerPlex 21 kit and Goldeneye 20A kit present a good consistency. The primer design is reasonable. The polymorphism of D1S1656 is good. The two kits can be used for human genetic analysis, paternity test, and individual identification in forensic practice.

  2. Diagnostic gap in Bovine viral diarrhea virus serology during the periparturient period in cattle.

    PubMed

    Bachofen, Claudia; Bollinger, Barbara; Peterhans, Ernst; Stalder, Hanspeter; Schweizer, Matthias

    2013-09-01

    Detection of antibodies against Bovine viral diarrhea virus (BVDV) in serum and milk by enzyme-linked immunosorbent assay (ELISA) is a crucial part of all ongoing national schemes to eradicate this important cattle pathogen. Serum and milk are regarded as equally suited for antibody measurement. However, when retesting a seropositive cow 1 day after calving, the serum was negative in 6 out of 9 different ELISAs. To further investigate this diagnostic gap around parturition, pre- and postcalving serum and milk samples of 5 cows were analyzed by BVDV antibody ELISA and serum neutralization test (SNT). By ELISA, 3 out of the 5 animals showed a diagnostic gap in the serum for up to 12 days around calving but all animals remained positive in SNT. In milk, the ELISA was strongly positive after birth but antibody levels decreased considerably within the next few days. Because of the immunoglobulin G (IgG)1-specific transport of serum antibodies into the mammary gland for colostrum production, the IgG subclass specificity of the total and the BVDV-specific antibodies were determined. Although all 5 animals showed a clear decrease in the total and BVDV-specific IgG1 antibody levels at parturition, the precalving IgG1-to-IgG2 ratios of the BVDV-specific antibodies were considerably lower in animals that showed the diagnostic gap. Results showed that BVDV seropositive cows may become "false" negative in several ELISAs in the periparturient period and suggest that the occurrence of this diagnostic gap is influenced by the BVDV-specific IgG subclass response of the individual animal.

  3. Optimizing Medical Kits for Spaceflight

    NASA Technical Reports Server (NTRS)

    Keenan, A. B,; Foy, Millennia; Myers, G.

    2014-01-01

    The Integrated Medical Model (IMM) is a probabilistic model that estimates medical event occurrences and mission outcomes for different mission profiles. IMM simulation outcomes describing the impact of medical events on the mission may be used to optimize the allocation of resources in medical kits. Efficient allocation of medical resources, subject to certain mass and volume constraints, is crucial to ensuring the best outcomes of in-flight medical events. We implement a new approach to this medical kit optimization problem. METHODS We frame medical kit optimization as a modified knapsack problem and implement an algorithm utilizing a dynamic programming technique. Using this algorithm, optimized medical kits were generated for 3 different mission scenarios with the goal of minimizing the probability of evacuation and maximizing the Crew Health Index (CHI) for each mission subject to mass and volume constraints. Simulation outcomes using these kits were also compared to outcomes using kits optimized..RESULTS The optimized medical kits generated by the algorithm described here resulted in predicted mission outcomes more closely approached the unlimited-resource scenario for Crew Health Index (CHI) than the implementation in under all optimization priorities. Furthermore, the approach described here improves upon in reducing evacuation when the optimization priority is minimizing the probability of evacuation. CONCLUSIONS This algorithm provides an efficient, effective means to objectively allocate medical resources for spaceflight missions using the Integrated Medical Model.

  4. A chromogranin A ELISA absent of an apparent high-dose hook effect observed in other chromogranin A ELISAs.

    PubMed

    Erickson, J Alan; Grenache, David G

    2016-01-15

    Routine testing for chromogranin A (CgA) using an established commercial ELISA revealed an apparent high-dose hook effect in approximately 15% of specimens. Investigations found the same effect in two additional ELISAs. We hypothesized that a CgA derived peptide(s) at high concentrations was responsible but experiments were inconclusive. Here we describe the analytical performance characteristics of the Chromoa™ CgA ELISA that did not display the apparent high-dose hook effect. Performance characteristics of the Chromoa ELISA were assessed. The reference interval was established utilizing healthy volunteers. Specimens producing the apparent high-dose hook effect in other assays were evaluated using the Chromoa ELISA. The limit of detection was 8ng/ml. Linearity was acceptable (slope=1.04, intercept=18.1 and r(2)=0.997). CVs were ≤4.6 and ≤9.3% for repeatability and within-laboratory imprecision, respectively. CgA was stable at ambient and refrigerated temperatures for a minimum of two and 14days, respectively. An upper reference interval limit of 95ng/ml was established. Specimens demonstrating the apparent high-dose hook effect in other ELISAs did not exhibit the phenomenon using the Chromoa ELISA. The Chromoa ELISA demonstrates acceptable performance for quantifying serum CgA. The apparent high-dose hook effect exhibited in other ELISAs was absent using the Chromoa assay. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Evaluation of tyrosine-kinase receptor c-KIT (c-KIT) mutations, mRNA and protein expression in canine leukemia: might c-KIT represent a therapeutic target?

    PubMed

    Giantin, M; Aresu, L; Aricò, A; Gelain, M E; Riondato, F; Martini, V; Comazzi, S; Dacasto, M

    2013-04-15

    The tyrosine-kinase receptor c-KIT (c-KIT) plays an important role in proliferation, survival and differentiation of progenitor cells in normal hematopoietic cells. In human hematological malignancies, c-KIT is mostly expressed by progenitor cell neoplasia and seldom by those involving mature cells. Tyrosine kinase inhibitors (TKIs) are actually licensed for the first- and second-line treatment of human hematologic disorders. Aim of the present study was to evaluate c-KIT mRNA and protein expression and complementary DNA (cDNA) mutations in canine leukemia. Eleven acute lymphoblastic leukemia (ALL) and acute undifferentiated leukemia (AUL) and 12 chronic lymphocytic leukemia (CLL) were enrolled in this study. The amounts of c-KIT mRNA and protein were determined, in peripheral blood samples, by using quantitative real time RT-PCR, flow cytometry and immunocytochemistry, respectively. The presence of mutations on c-KIT exons 8-11 and 17 were investigated by cDNA sequencing. Higher amounts of c-KIT mRNA were found in ALL/AUL compared to CLL, and this latter showed a lower pattern of gene expression. Transcriptional data were confirmed at the protein level. No significant gain-of-function mutations were ever observed in both ALL/AUL and CLL. Among canine hematological malignancies, ALL/AUL typically show a very aggressive biological behavior, partly being attributable to the lack of efficacious therapeutic options. The high level of c-KIT expression found in canine ALL/AUL might represent the rationale for using TKIs in future clinical trials. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Evaluation of a Real-Time PCR Kit for Detecting Escherichia coli O157 in Bovine Fecal Samples

    PubMed Central

    Bono, James L.; Keen, James E.; Miller, Laura C.; Fox, James M.; Chitko-McKown, Carol G.; Heaton, Michael P.; Laegreid, William W.

    2004-01-01

    A commercially available real-time, rapid PCR test was evaluated for its ability to detect Escherichia coli O157. Both the sensitivity and specificity of the assay were 99% for isolates in pure culture. The assay detected 1 CFU of E. coli O157:H7 g−1 in artificially inoculated bovine feces following enrichment. PMID:15006817

  7. Development and evaluation of an immunochromatographic assay using a gp51 monoclonal antibody for the detection of antibodies against the bovine leukemia virus.

    PubMed

    Kim, Eun-Ju; Cheong, Kwang-Myun; Joung, Ha-Kyung; Kim, Bo-Hye; Song, Jae-Young; Cho, In-Soo; Lee, Kyoung-Ki; Shin, Yeun-Kyung

    2016-12-30

    Infection of cattle with bovine leukemia virus (BLV) has been observed and reported worldwide, including in Korea. The onsite identification of infected cattle would help decreasing and eradicating BLV infections on farms. Here, we present a new immunochromatographic assay that employs monoclonal antibodies (MAbs) for the detection of antibodies against BLV in the field. BLV envelope glycoprotein (gp)51 was expressed in E. coli , and MAbs against recombinant BLV gp51 were generated for the development of an immunochromatographic assay to detect BLV antibodies in cattle. The sensitivity and specificity of the assay were determined by comparing these results with those obtained from a standard enzyme linked immunosorbent assay (ELISA). A total of 160 bovine sera were used to evaluate the new immunochromatographic assay. Using ELISA as a reference standard, the relative specificity and sensitivity of this assay were determined to be 94.7% and 98%, respectively. Because of its high sensitivity and specificity, this BLV antibody detection assay would be suitable for the onsite identification of BLV infection in the field.

  8. Development of anti-bovine IgA single chain variable fragment and its application in diagnosis of foot-and-mouth disease

    PubMed Central

    Sridevi, N. V.; Shukra, A. M.; Neelakantam, B.; Anilkumar, J.; Madhanmohan, M.; Rajan, S.; Dev Chandran

    2014-01-01

    Recombinant antibody fragments like single chain variable fragments (scFvs) represent an attractive yet powerful alternative to immunoglobulins and hold great potential in the development of clinical diagnostic/therapeutic reagents. Structurally, scFvs are the smallest antibody fragments capable of retaining the antigen-binding capacity of whole antibodies and are composed of an immunoglobulin (Ig) variable light (VL) and variable heavy (VH) chain joined by a flexible polypeptide linker. In the present study, we constructed a scFv against bovine IgA from a hybridoma cell line IL-A71 that secretes a monoclonal antibody against bovine IgA using recombinant DNA technology. The scFv was expressed in Escherichia coli and purified using immobilized metal affinity chromatography (IMAC). The binding activity and specificity of the scFv was established by its non-reactivity toward other classes of immunoglobulins as determined by enzyme-linked immunosorbent assay (ELISA) and immunoblot analysis. Kinetic measurement of the scFv indicated that the recombinant antibody fragment had an affinity in picomolar range toward purified IgA. Furthermore, the scFv was used to develop a sensitive ELISA for the detection of foot and mouth disease virus (FMDV) carrier animals. PMID:24678404

  9. Education Payload Operation - Kit D

    NASA Technical Reports Server (NTRS)

    Keil, Matthew

    2009-01-01

    Education Payload Operation - Kit D (EPO-Kit D) includes education items that will be used to support the live International Space Station (ISS) education downlinks and Education Payload Operation (EPO) demonstrations onboard the ISS. The main objective of EPO-Kit D supports the National Aeronautics and Space Administration (NASA) goal of attracting students to study and seek careers in science, technology, engineering, and mathematics.

  10. Cardiac c-Kit Biology Revealed by Inducible Transgenesis.

    PubMed

    Gude, Natalie A; Firouzi, Fareheh; Broughton, Kathleen M; Ilves, Kelli; Nguyen, Kristine P; Payne, Christina R; Sacchi, Veronica; Monsanto, Megan M; Casillas, Alexandria R; Khalafalla, Farid G; Wang, Bingyan J; Ebeid, David E; Alvarez, Roberto; Dembitsky, Walter P; Bailey, Barbara A; van Berlo, Jop; Sussman, Mark A

    2018-06-22

    Biological significance of c-Kit as a cardiac stem cell marker and role(s) of c-Kit+ cells in myocardial development or response to pathological injury remain unresolved because of varied and discrepant findings. Alternative experimental models are required to contextualize and reconcile discordant published observations of cardiac c-Kit myocardial biology and provide meaningful insights regarding clinical relevance of c-Kit signaling for translational cell therapy. The main objectives of this study are as follows: demonstrating c-Kit myocardial biology through combined studies of both human and murine cardiac cells; advancing understanding of c-Kit myocardial biology through creation and characterization of a novel, inducible transgenic c-Kit reporter mouse model that overcomes limitations inherent to knock-in reporter models; and providing perspective to reconcile disparate viewpoints on c-Kit biology in the myocardium. In vitro studies confirm a critical role for c-Kit signaling in both cardiomyocytes and cardiac stem cells. Activation of c-Kit receptor promotes cell survival and proliferation in stem cells and cardiomyocytes of either human or murine origin. For creation of the mouse model, the cloned mouse c-Kit promoter drives Histone2B-EGFP (enhanced green fluorescent protein; H2BEGFP) expression in a doxycycline-inducible transgenic reporter line. The combination of c-Kit transgenesis coupled to H2BEGFP readout provides sensitive, specific, inducible, and persistent tracking of c-Kit promoter activation. Tagging efficiency for EGFP+/c-Kit+ cells is similar between our transgenic versus a c-Kit knock-in mouse line, but frequency of c-Kit+ cells in cardiac tissue from the knock-in model is 55% lower than that from our transgenic line. The c-Kit transgenic reporter model reveals intimate association of c-Kit expression with adult myocardial biology. Both cardiac stem cells and a subpopulation of cardiomyocytes express c-Kit in uninjured adult heart

  11. Molecular Alterations of KIT Oncogene in Gliomas

    PubMed Central

    Gomes, Ana L.; Reis-Filho, Jorge S.; Lopes, José M.; Martinho, Olga; Lambros, Maryou B. K.; Martins, Albino; Schmitt, Fernando; Pardal, Fernando; Reis, Rui M.

    2007-01-01

    Gliomas are the most common and devastating primary brain tumours. Despite therapeutic advances, the majority of gliomas do not respond either to chemo or radiotherapy. KIT, a class III receptor tyrosine kinase (RTK), is frequently involved in tumourigenic processes. Currently, KIT constitutes an attractive therapeutic target. In the present study we assessed the frequency of KIT overexpression in gliomas and investigated the genetic mechanisms underlying KIT overexpression. KIT (CD117) immunohistochemistry was performed in a series of 179 gliomas of various grades. KIT activating gene mutations (exons 9, 11, 13 and 17) and gene amplification analysis, as defined by chromogenic in situ hybridization (CISH) and quantitative real-time PCR (qRT-PCR) were performed in CD117 positive cases. Tumour cell immunopositivity was detected in 15.6% (28/179) of cases, namely in 25% (1/4) of pilocytic astrocytomas, 25% (5/20) of diffuse astrocytomas, 20% (1/5) of anaplastic astrocytomas, 19.5% (15/77) of glioblastomas and one third (3/9) of anaplastic oligoastrocytomas. Only 5.7% (2/35) of anaplastic oligodendrogliomas showed CD117 immunoreactivity. No association was found between tumour CD117 overexpression and patient survival. In addition, we also observed CD117 overexpression in endothelial cells, which varied from 0–22.2% of cases, being more frequent in high-grade lesions. No KIT activating mutations were identified. Interestingly, CISH and/or qRT-PCR analysis revealed the presence of KIT gene amplification in 6 glioblastomas and 2 anaplastic oligoastrocytomas, corresponding to 33% (8/24) of CD117 positive cases. In conclusion, our results demonstrate that KIT gene amplification rather than gene mutation is a common genetic mechanism underlying KIT expression in subset of malignant gliomas. Further studies are warranted to determine whether glioma patients exhibiting KIT overexpression and KIT gene amplification may benefit from therapy with anti-KIT RTK inhibitors. PMID

  12. KIT Mutations Are Common in Testicular Seminomas

    PubMed Central

    Kemmer, Kathleen; Corless, Christopher L.; Fletcher, Jonathan A.; McGreevey, Laura; Haley, Andrea; Griffith, Diana; Cummings, Oscar W.; Wait, Cecily; Town, Ajia; Heinrich, Michael C.

    2004-01-01

    Expression of KIT tyrosine kinase is critical for normal germ cell development and is observed in the majority of seminomas. Activating mutations in KIT are common in gastrointestinal stromal tumors and mastocytosis. In this study we examined the frequency and spectrum of KIT mutations in 54 testicular seminomas, 1 ovarian dysgerminoma and 37 non-seminomatous germ cell tumors (NSGCT). Fourteen seminomas (25.9%) contained exon 17 point mutations including D816V (6 cases), D816H (3 cases), Y823D (2 cases), and single examples of Y823C, N822K, and T801I. No KIT mutations were found in the ovarian dysgerminoma or the NSGCTs. In transient transfection assays, mutant isoforms D816V, D816H, Y823D, and N822K were constitutively phosphorylated in the absence of the natural ligand for KIT, stem cell factor (SCF). In contrast, activation of T801I and wild-type KIT required SCF. Mutants N822K and Y823D were inhibited by imatinib mesylate (Gleevec, previously STI571) whereas D816V and D816H were both resistant to imatinib mesylate. Biochemical evidence of KIT activation, as assessed by KIT phosphorylation and KIT association with phosphatidylinositol (PI) 3-kinase in tumor cell lysates, was largely confined to seminomas with a genomic KIT mutation. These findings suggest that activating KIT mutations may contribute to tumorigenesis in a subset of seminomas, but are not involved in NSGCT. PMID:14695343

  13. Serological detection systems for identification of cows shedding bovine foamy virus via milk.

    PubMed

    Romen, Fabian; Backes, Perdita; Materniak, Magda; Sting, Reinhard; Vahlenkamp, Thomas W; Riebe, Roland; Pawlita, Michael; Kuzmak, Jacek; Löchelt, Martin

    2007-07-20

    The biology of foamy viruses, their mode of transmission and disease potential in their natural host and after interspecies transmission are largely unknown. To gain insights into the prevalence of bovine foamy virus (BFV) and its zoonotic potential, enzyme-linked immunosorbent assays (ELISAs) were established to determine antibody responses against Gag, Env, and the non-structural protein Bet in bovine serum and milk. In Polish cattle, strong Gag reactivity was most frequent (41.5%) and strongly associated with Bet antibodies, Env antibodies were less frequent. German cattle showed a low overall BFV antibody prevalence of 6.8%. Besides clearly BFV-positive animals, a substantial number of weakly reacting cattle were identified. BFV-specific antibodies were also detectable in milk. BFV was isolated from PBLs and milk cells of BFV-positive cattle but not from antibody-negative or weakly reacting animals. The implications of these findings for the potential interspecies transmission of BFV to humans will be discussed.

  14. Evaluation of monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) for antigen detection of foot-and-mouth disease virus using clinical samples.

    PubMed

    Morioka, Kazuki; Fukai, Katsuhiko; Sakamoto, Kenichi; Yoshida, Kazuo; Kanno, Toru

    2014-01-01

    A monoclonal antibody-based sandwich direct ELISA (MSD-ELISA) method was previously developed for foot-and-mouth disease (FMD) viral antigen detection. Here we evaluated the sensitivity and specificity of two FMD viral antigen detection MSD-ELISAs and compared them with conventional indirect sandwich (IS)-ELISA. The MSD-ELISAs were able to detect the antigen in saliva samples of experimentally-infected pigs for a longer term compared to the IS-ELISA. We also used 178 RT-PCR-positive field samples from cattle and pigs affected by the 2010 type-O FMD outbreak in Japan, and we found that the sensitivities of both MSD-ELISAs were about 7 times higher than that of the IS-ELISA against each sample (P<0.01). In terms of the FMD-positive farm detection rate, the sensitivities of the MSD-ELISAs were about 6 times higher than that of the IS-ELISA against each farm (P<0.01). Although it is necessary to conduct further validation study using the other virus strains, MSD-ELISAs could be appropriate as a method to replace IS-ELISA for FMD antigen detection.

  15. Optics learning through affordable kit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    P, Anusha N, E-mail: anushnp@gmail.com, E-mail: chitrashaji@gmail.com, E-mail: aloksharan@gmail.com; Shaji, Chitra, E-mail: anushnp@gmail.com, E-mail: chitrashaji@gmail.com, E-mail: aloksharan@gmail.com; Sharan, Alok, E-mail: anushnp@gmail.com, E-mail: chitrashaji@gmail.com, E-mail: aloksharan@gmail.com

    2014-10-15

    An affordable kit which helps to understand some of the optical phenomena qualitatively and quantitatively is presented in this paper. It supplements optics taught in classes. The kit consists of equipments which are available in the market at nominal cost such as laser pointer, lenses, glass plates, razor blades, coins, ball bearing etc. Experiments which come under wave optics (interference and diffraction) and ray optics (reflection and refraction) are explained using this kit.

  16. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... resin kits consisting of a base material component (Class 3, Packing Group II or III) and an activator...

  17. Detection of toxoplasma-specific immunoglobulin G in human sera: performance comparison of in house Dot-ELISA with ECLIA and ELISA.

    PubMed

    Teimouri, Aref; Modarressi, Mohammad Hossein; Shojaee, Saeedeh; Mohebali, Mehdi; Zouei, Nima; Rezaian, Mostafa; Keshavarz, Hossein

    2018-05-08

    In the current study, performance of electrochemiluminescence immunoassay (ECLIA) in detection of anti-toxoplasma IgG in human sera was compared with that of enzyme-linked immunosorbent assay (ELISA). Furthermore, performance of an in house Dot-ELISA in detection of anti-toxoplasma IgG was compared with that of ECLIA and ELISA. In total, 219 human sera were tested to detect anti-toxoplasma IgG using Dynex DS2® and Roche Cobas® e411 Automated Analyzers. Discordant results rechecked using immunofluorescence assay (IFA). Then, sera were used in an in house Dot-ELISA to assess toxoplasma-specific IgG. Of the 219 samples, two samples were found undetermined using ECLIA but reactive using ELISA. Using IFA, the two sera were reported unreactive. Furthermore, two samples were found reactive using ECLIA and unreactive using ELISA. These samples were reported reactive using IFA. The overall agreement for the two former methods was 98% (rZ0.98.1; P < 0.001). The intrinsic parameters calculated for in house Dot-ELISA included sensitivity of 79.5, specificity of 78.2, and accuracy of 78.9%, compared to ECLIA and ELISA. Positive and negative predictive values included 82.9 and 74.2%, respectively. A 100% sensitivity was found in in house Dot-ELISA for highly reactive sera in ECLIA and ELISA. ECLIA is appropriate for the first-line serological screening tests and can replace ELISA due to high speed, sensitivity, and specificity, particularly in large laboratories. Dot-ELISA is a rapid, sensitive, specific, cost-effective, user-friendly, and field-portable technique and hence can be used for screening toxoplasmosis, especially in rural fields or less equipped laboratories.

  18. FUELS IN SOIL TEST KIT: FIELD USE OF DIESEL DOG SOIL TEST KITS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Susan S. Sorini; John F. Schabron; Joseph F. Rovani, Jr.

    Western Research Institute (WRI) has developed a new commercial product ready for technology transfer, the Diesel Dog{reg_sign} Portable Soil Test Kit, for performing analysis of fuel-contaminated soils in the field. The technology consists of a method developed by WRI (U.S. Patents 5,561,065 and 5,976,883) and hardware developed by WRI that allows the method to be performed in the field (patent pending). The method is very simple and does not require the use of highly toxic reagents. The aromatic components in a soil extract are measured by absorption at 254 nm with a field-portable photometer. WRI added significant value to themore » technology by taking the method through the American Society for Testing and Materials (ASTM) approval and validation processes. The method is designated as ASTM Method D 5831-96, Standard Test Method for Screening Fuels in Soils. This ASTM designation allows the method to be used for federal compliance activities. In June 2001, the Diesel Dog technology won an American Chemical Society Regional Industrial Innovations Award. To gain field experience with the new technology, Diesel Dog kits have been used for a variety of site evaluation and cleanup activities. Information gained from these activities has led to improvements in hardware configurations and additional insight into correlating Diesel Dog results with results from laboratory methods. The Wyoming Department of Environmental Quality (DEQ) used Diesel Dog Soil Test Kits to guide cleanups at a variety of sites throughout the state. ENSR, of Acton, Massachusetts, used a Diesel Dog Portable Soil Test Kit to evaluate sites in the Virgin Islands and Georgia. ChemTrack and the U.S. Army Corps of Engineers successfully used a test kit to guide excavation at an abandoned FAA fuel-contaminated site near Fairbanks, Alaska. Barenco, Inc. is using a Diesel Dog Portable Soil Test Kit for site evaluations in Canada. A small spill of diesel fuel was cleaned up in Laramie, Wyoming using a

  19. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 32 2012-07-01 2012-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have... publicizes its recognition of the first test kit that meets both the negative response and positive response...

  20. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  1. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  2. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  3. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  4. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  5. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  6. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent...

  7. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  8. 46 CFR 184.710 - First-aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First-aid kits. 184.710 Section 184.710 Shipping COAST... CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Miscellaneous § 184.710 First-aid kits. A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents...

  9. Expression of p24 gag protein of bovine leukemia virus in insect cells and its use in immunodetection of the disease.

    PubMed

    Larsen, Alejandra; Gonzalez, Ester Teresa; Serena, María Soledad; Echeverría, María Gabriela; Mortola, Eduardo

    2013-06-01

    Bovine leukemia is a common retroviral infection of cattle. The disease is characterized by a strong immunological response to several viral proteins, but the antibodies against p24 and gp51 are predominant. In this study, a recombinant baculovirus containing the gag gene p24 was constructed and the protein, used as antigen, analyzed by western blot and an indirect in-house rp24-ELISA test. This allowed detecting the presence of antibodies for bovine leukemia virus in a panel of cattle sera. The authentication of the protein expands its potential use for different medical applications, from improved diagnosis of the disease to source of antigens to be included in a subunit vaccine.

  10. Validation of a PCR-based method for the detection of various rendered materials in feedstuffs using a forensic DNA extraction kit.

    PubMed

    Myers, Michael J; Yancy, Haile F; Araneta, Michael; Armour, Jennifer; Derr, Janice; Hoostelaere, Lawrence A D; Farmer, Doris; Jackson, Falana; Kiessling, William M; Koch, Henry; Lin, Huahua; Liu, Yan; Mowlds, Gabrielle; Pinero, David; Riter, Ken L; Sedwick, John; Shen, Yuelian; Wetherington, June; Younkins, Ronsha

    2006-01-01

    A method trial was initiated to validate the use of a commercial DNA forensic kit to extract DNA from animal feed as part of a PCR-based method. Four different PCR primer pairs (one bovine pair, one porcine pair, one ovine primer pair, and one multispecies pair) were also evaluated. Each laboratory was required to analyze a total of 120 dairy feed samples either not fortified (control, true negative) or fortified with bovine meat and bone meal, porcine meat and bone meal (PMBM), or lamb meal. Feeds were fortified with the animal meals at a concentration of 0.1% (wt/wt). Ten laboratories participated in this trial, and each laboratory was required to evaluate two different primer pairs, i.e., each PCR primer pair was evaluated by five different laboratories. The method was considered to be validated for a given animal source when three or more laboratories achieved at least 97% accuracy (29 correct of 30 samples for 96.7% accuracy, rounded up to 97%) in detecting the fortified samples for that source. Using this criterion, the method was validated for the bovine primer because three laboratories met the criterion, with an average accuracy of 98.9%. The average false-positive rate was 3.0% in these laboratories. A fourth laboratory was 80% accurate in identifying the samples fortified with bovine meat and bone meal. A fifth laboratory was not able to consistently extract the DNA from the feed samples and did not achieve the criterion for accuracy for either the bovine or multispecies PCR primers. For the porcine primers, the method was validated, with four laboratories meeting the criterion for accuracy with an average accuracy of 99.2%. The fifth laboratory had a 93.3% accuracy outcome for the porcine primer. Collectively, these five laboratories had a 1.3% false-positive rate for the porcine primer. No laboratory was able to meet the criterion for accuracy with the ovine primers, most likely because of problems with the synthesis of the primer pair; none of the

  11. 46 CFR 121.710 - First-aid kits.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First-aid kits. 121.710 Section 121.710 Shipping COAST... SYSTEMS AND EQUIPMENT Miscellaneous § 121.710 First-aid kits. A vessel must carry either a first-aid kit... kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A...

  12. Megakaryocytes compensate for Kit insufficiency in murine arthritis.

    PubMed

    Cunin, Pierre; Penke, Loka R; Thon, Jonathan N; Monach, Paul A; Jones, Tatiana; Chang, Margaret H; Chen, Mary M; Melki, Imene; Lacroix, Steve; Iwakura, Yoichiro; Ware, Jerry; Gurish, Michael F; Italiano, Joseph E; Boilard, Eric; Nigrovic, Peter A

    2017-05-01

    The growth factor receptor Kit is involved in hematopoietic and nonhematopoietic development. Mice bearing Kit defects lack mast cells; however, strains bearing different Kit alleles exhibit diverse phenotypes. Herein, we investigated factors underlying differential sensitivity to IgG-mediated arthritis in 2 mast cell-deficient murine lines: KitWsh/Wsh, which develops robust arthritis, and KitW/Wv, which does not. Reciprocal bone marrow transplantation between KitW/Wv and KitWsh/Wsh mice revealed that arthritis resistance reflects a hematopoietic defect in addition to mast cell deficiency. In KitW/Wv mice, restoration of susceptibility to IgG-mediated arthritis was neutrophil independent but required IL-1 and the platelet/megakaryocyte markers NF-E2 and glycoprotein VI. In KitW/Wv mice, platelets were present in numbers similar to those in WT animals and functionally intact, and transfer of WT platelets did not restore arthritis susceptibility. These data implicated a platelet-independent role for the megakaryocyte, a Kit-dependent lineage that is selectively deficient in KitW/Wv mice. Megakaryocytes secreted IL-1 directly and as a component of circulating microparticles, which activated synovial fibroblasts in an IL-1-dependent manner. Transfer of WT but not IL-1-deficient megakaryocytes restored arthritis susceptibility to KitW/Wv mice. These findings identify functional redundancy among Kit-dependent hematopoietic lineages and establish an unanticipated capacity of megakaryocytes to mediate IL-1-driven systemic inflammatory disease.

  13. Evaluation of a Fast and Simple Sample Preparation Method for Polybrominated Diphenyl Ether (PBDE) Flame Retardants and Dichlorodiphenyltrichloroethane (DDT) Pesticides in Fish for Analysis by ELISA Compared with GC-MS/MS.

    PubMed

    Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J

    2015-05-13

    A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.

  14. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  15. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  16. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  17. 21 CFR 876.5210 - Enema kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Enema kit. 876.5210 Section 876.5210 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GASTROENTEROLOGY-UROLOGY DEVICES Therapeutic Devices § 876.5210 Enema kit. (a) Identification. An enema kit is a...

  18. Subclinical breakdown with infectious bovine rhinotracheitis virus infection in dairy herd of high health status.

    PubMed

    Pritchard, G C; Banks, M; Vernon, R E

    2003-07-26

    Infectious bovine rhinotracheitis (IBR) virus infection was detected by an antibody ELISA in the bulk milk of a large closed dairy herd of high health status in an area of low cattle density in East Anglia. The herd was managed under high standards of biosecurity and was known to have been serologically free of IBR virus for the previous 13 years. Although over 70 per cent of the cows had seroconverted to IBR virus no clinical signs were observed apart from a slight bilateral watery ocular discharge in a few cows, and their performance and productivity were unaffected. The causal virus, which was isolated after it had been reactivated with corticosteroid, had the DNA profile of a bovine herpesvirus type 1 strain normally associated with clinically severe respiratory disease. In spite of extensive enquiries and seroepidemiological investigations the source of the infection was not determined.

  19. Comparison between DNA Detection in Trigeminal Nerve Ganglia and Serology to Detect Cattle Infected with Bovine Herpesviruses Types 1 and 5

    PubMed Central

    Furtado, Agustin; Torres, Fabrício Dias; Franco, Ana Cláudia; Maisonnave, Jacqueline; Roehe, Paulo Michel

    2016-01-01

    Bovine herpesviruses (BoHVs) types 1 (BoHV-1) and 5 (BoHV-5) are alphaherpesviruses of major importance to the bovine production chain. Such viruses are capable of establishing latent infections in neuronal tissues. Infected animals tend to develop a serological response to infection; however, such response—usually investigated by antibody assays in serum—may eventually not be detected in laboratory assays. Nevertheless, serological tests such as virus neutralization (VN) and various enzyme-linked immunosorbent assays (ELISAs) are widely employed to check individual or herd status of BoHV infections. The correlation between detection of antibodies and the presence of viral nucleic acids as indicatives of infection in infected cattle has not been deeply examined. In order to investigate such correlation, 248 bovine serum samples were tested by VN to BoHV-1 and BoHV-5, as well as in a widely employed (though not type-differential) gB ELISA (IDEXX IBR gB X2 Ab Test) in search for antibodies to BoHVs. Immediately after blood withdrawal, cattle were slaughtered and trigeminal ganglia (TG) excised for DNA extraction and viral nucleic acid detection (NAD) by nested PCR. Neutralizing antibodies to BoHV-1 and/or BoHV-5 were detected in 44.8% (111/248) of sera, whereas the gB ELISA detected antibodies in 51.2% (127/248) of the samples. However, genomes of either BoHV-1, BoHV-5, or both, were detected in TGs of 85.9% (213/248) of the animals. These findings reveal that the assays designed to detect antibodies to BoHV-1 and/or BoHV-5 employed here may fail to detect a significant number of latently infected animals (in this study, 35.7%). From such data, it is clear that antibody assays are poorly correlated with detection of viral genomes in BoHV-1 and BoHV-5-infected animals. PMID:27224314

  20. SHP-1 Binds and Negatively Modulates the c-Kit Receptor by Interaction with Tyrosine 569 in the c-Kit Juxtamembrane Domain

    PubMed Central

    Kozlowski, Maya; Larose, Louise; Lee, Fai; Le, Duc Mingh; Rottapel, Robert; Siminovitch, Katherine A.

    1998-01-01

    The SH2 domain-containing SHP-1 tyrosine phosphatase has been shown to negatively regulate a broad spectrum of growth factor- and cytokine-driven mitogenic signaling pathways. Included among these is the cascade of intracellular events evoked by stem cell factor binding to c-Kit, a tyrosine kinase receptor which associates with and is dephosphorylated by SHP-1. Using a series of glutathione S-transferase (GST) fusion proteins containing either tyrosine-phosphorylated segments of the c-Kit cytosolic region or the SH2 domains of SHP-1, we have shown that SHP-1 interacts with c-Kit by binding selectively to the phosphorylated c-Kit juxtamembrane region and that the association of c-Kit with the larger of the two SHP-1 isoforms may be mediated through either the N-terminal or C-terminal SHP-1 SH2 domain. The results of binding assays with mutagenized GST-Kit juxtamembrane fusion proteins and competitive inhibition assays with phosphopeptides encompassing each c-Kit juxtamembrane region identified the tyrosine residue at position 569 as the major site for binding of SHP-1 to c-Kit and suggested that tyrosine 567 contributes to, but is not required for, this interaction. By analysis of Ba/F3 cells retrovirally transduced to express c-Kit receptors, phenylalanine substitution of c-Kit tyrosine residue 569 was shown to be associated with disruption of c-Kit–SHP-1 binding and induction of hyperproliferative responses to stem cell factor. Although phenylalanine substitution of c-Kit tyrosine residue 567 in the Ba/F3–c-Kit cells did not alter SHP-1 binding to c-Kit, the capacity of a second c-Kit-binding tyrosine phosphatase, SHP-2, to associate with c-Kit was markedly reduced, and the cells again showed hyperproliferative responses to stem cell factor. These data therefore identify SHP-1 binding to tyrosine 569 on c-Kit as an interaction pivotal to SHP-1 inhibitory effects on c-Kit signaling, but they indicate as well that cytosolic protein tyrosine phosphatases other

  1. A First Application of Enzyme-Linked Immunosorbent Assay for Screening Cyclodiene Insecticides in Ground Water

    USGS Publications Warehouse

    Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.

    1996-01-01

    A commercially available enzyme-linked immunosorbent assay (ELISA) plate kit for screening of cyclodiene insecticides (aldrin, chlordane, dieldrin, endosulfan, endrin, and heptachlor) was evaluated for sensitivity, cross reactivity, and overall performance using groundwater samples from a contaminated site. Ground-water contaminants included several pesticide compounds and their manufacturing byproducts, as well as many other organic and inorganic compounds. Cross-reactivity studies were carried out for the cyclodiene compounds, and results were compared to those listed by the manufacturer. Data obtained were used to evaluate the sensitivity of the ELISA kit to the cyclodiene compounds in ground water samples with a contaminated matrix. The method quantitation limit for the ELISA kit was 15 ??g/L (as chlordane). Of the 56 ground-water samples analyzed using the ELISA plate kits, more than 85% showed cyclodiene insecticide contamination. The ELISA kit showed excellent potential as a screening tool for sites with suspected groundwater contamination by insecticides.

  2. Fluorescence ELISA based on glucose oxidase-mediated fluorescence quenching of quantum dots for highly sensitive detection of Hepatitis B.

    PubMed

    Wu, Yunqing; Zeng, Lifeng; Xiong, Ying; Leng, Yuankui; Wang, Hui; Xiong, Yonghua

    2018-05-01

    Herein, we present a novel sandwich fluorescence enzyme linked immunosorbent assay (ELISA) for highly sensitive detection of Hepatitis B virus surface antigen (HBsAg) based on glucose oxidase (GOx)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (MPA-QDs). In this system, hydrogen peroxide (H 2 O 2 ) sensitive MPA-QDs was used as a signal output, and glucose oxidase (GOx) was used as label which can generate H 2 O 2 via catalytic oxidation of glucose. The proposed method showed dynamic linear detection of HBsAg both in the range of 47pgmL -1 ~ 380pgmL -1 and 0.75ngmL -1 ~ 12.12ngmL -1 . The detection limit of the proposed fluorescence ELISA was 1.16pgmL -1 , which was approximately 430-fold lower than that of horseradish peroxidase (HRP)-based conventional ELISA. The average recoveries for HBsAg-spiked serum samples ranged from 98.0% to 126.8% with the relative standard derivation below 10%, thus indicating acceptable precision and high reproducibility of the proposed fluorescence ELISA for HBsAg detection. Additionally, the developed method showed no false positive results analyzing 35 real HBsAg-negative serum samples, and exhibited excellent agreement (R 2 =0.9907) with a commercial time-resolved fluorescence immunoassay (TRFIA) kit for detecting 31 HBsAg-positive serum samples. In summary, the proposed method based on fluorescence quenching of H 2 O 2 sensitive QDs is considerably to be an excellent biodetection platform with ultrahigh sensitivity, good accuracy and excellent reliability. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Evaluation of a dengue NS1 antigen detection assay sensitivity and specificity for the diagnosis of acute dengue virus infection.

    PubMed

    Hermann, Laura L; Thaisomboonsuk, Butsaya; Poolpanichupatam, Yongyuth; Jarman, Richard G; Kalayanarooj, Siripen; Nisalak, Ananda; Yoon, In-Kyu; Fernandez, Stefan

    2014-10-01

    Currently, no dengue NS1 detection kit has regulatory approval for the diagnosis of acute dengue fever. Here we report the sensitivity and specificity of the InBios DEN Detect NS1 ELISA using a panel of well characterized human acute fever serum specimens. The InBios DENV Detect NS1 ELISA was tested using a panel composed of 334 serum specimens collected from acute febrile patients seeking care in a Bangkok hospital in 2010 and 2011. Of these patients, 314 were found to have acute dengue by either RT-PCR and/or anti-dengue IgM/IgG ELISA. Alongside the InBios NS1 ELISA kit, we compared the performance characteristics of the BioRad Platelia NS1 antigen kit. The InBios NS1 ELISA Ag kit had a higher overall sensitivity (86% vs 72.8%) but equal specificity (100%) compared to the BioRad Platelia kit. The serological status of the patient significantly influenced the outcome. In primary infections, the InBios NS1 kit demonstrated a higher sensitivity (98.8%) than in secondary infections (83.5%). We found significant variation in the sensitivity of the InBios NS1 ELISA kit depending on the serotype of the dengue virus and also found decreasing sensitivity the longer after the onset of illness, showing 100% sensitivity early during illness, but dropping below 50% by Day 7. The InBios NS1 ELISA kit demonstrated high accuracy when compared to the initial clinical diagnosis with greater than 85% agreement when patients were clinically diagnosed with dengue illness. Results presented here suggest the accurate detection of circulating dengue NS1 by the InBios DENV Detect NS1 ELISA can provide clinicians with a useful tool for diagnosis of early dengue infections.

  4. Pim1 kinase regulates c-Kit gene translation.

    PubMed

    An, Ningfei; Cen, Bo; Cai, Houjian; Song, Jin H; Kraft, Andrew; Kang, Yubin

    2016-01-01

    Receptor tyrosine kinase, c-Kit (CD117) plays a pivotal role in the maintenance and expansion of hematopoietic stem/progenitor cells (HSPCs). Additionally, over-expression and/or mutational activation of c-Kit have been implicated in numerous malignant diseases including acute myeloid leukemia. However, the translational regulation of c-Kit expression remains largely unknown. We demonstrated that loss of Pim1 led to specific down-regulation of c-Kit expression in HSPCs of Pim1 -/- mice and Pim1 -/- 2 -/- 3 -/- triple knockout (TKO) mice, and resulted in attenuated ERK and STAT3 signaling in response to stimulation with stem cell factor. Transduction of c-Kit restored the defects in colony forming capacity seen in HSPCs from Pim1 -/- and TKO mice. Pharmacologic inhibition and genetic modification studies using human megakaryoblastic leukemia cells confirmed the regulation of c-Kit expression by Pim1 kinase: i.e., Pim1-specific shRNA knockdown down-regulated the expression of c-Kit whereas overexpression of Pim1 up-regulated the expression of c-Kit. Mechanistically, inhibition or knockout of Pim1 kinase did not affect the transcription of c-Kit gene. Pim1 kinase enhanced c-Kit 35 S methionine labeling and increased the incorporation of c-Kit mRNAs into the polysomes and monosomes, demonstrating that Pim1 kinase regulates c-Kit expression at the translational level. Our study provides the first evidence that Pim1 regulates c-Kit gene translation and has important implications in hematopoietic stem cell transplantation and cancer treatment.

  5. A quantitative indirect ELISA to monitor the effectiveness of rabies vaccination in domestic and wild carnivores.

    PubMed

    Servat, A; Feyssaguet, M; Blanchard, I; Morize, J L; Schereffer, J L; Boue, F; Cliquet, F

    2007-01-10

    This paper reports a new ELISA to measure the level of rabies anti-glycoprotein G antibodies after vaccination. The Platelia Rabies II kit was evaluated on different populations of dogs, cats and foxes. For each target species, sera from naive, unvaccinated and vaccinated animals were tested. Platelia Rabies II results were compared to the reference fluorescent antibody virus neutralisation test (for dogs and cats) and to a published in house ELISA test (for foxes). The Platelia Rabies II test was found to be highly specific whatever the species (more than 98%) using a cut-off value of 0.5 EU/ml. The index of sensitivity was between 92.4% and 94.5% for fox samples, and reached 83% for domestic carnivores. Data collected by testing field samples revealed that the rate of false negative results ranged between 8.9% and 11.1% and the rate of false positive results ranged between 1% and 2% for the dog/cat population. Therefore, the Platelia Rabies II test described here would be a good candidate for routine detection of rabies antibodies not only in domestic carnivores (within the framework of international trade) but also in foxes for the follow up of rabies oral vaccination programs.

  6. [Forensic Application of HuaxiaTM Platinum Kit].

    PubMed

    Wang, Y L; Sheng, X; Li, M; Chen, Y L; Lin, Y; Chen, L Q

    2017-04-01

    To investigate the genetic polymorphism of 23 autosomal STR loci of Huaxia™ Platinum kit in Chinese Han population, and to evaluate the forensic efficiency of Huaxia™ Platinum kit. A total of 500 unrelated healthy individuals from Han population were genotyped with Huaxia™ Platinum kit. The frequency distribution and the parameter of population genetics of STR loci were analysed statistically. Huaxia™ Platinum kit was compared with other 7 commercial STR kits commonly seen at home and abroad in the number of STR loci, interior label, fluorescent mark, total number of alleles in Ladder and system effectiveness. All the 23 autosomal STR loci were consistent with Hardy-Weinberg equilibrium ( P >0.05). The discrimination power was 0.791 5-0.986 2. The polymorphism information content (PIC) was 0.559 0-0.914 0. The combined discrimination power (CDP) was 1-4.1×10⁻²⁸, while combined probability of paternity exclusion in trio (CPET) and in duo (CPED) were 1-4.1×10⁻¹⁰ and 1-8.4×10⁻⁷, respectively. Compared with other 7 kits, Huaxia™ Platinum kit contained the most number of alleles within the Ladder. All the 23 autosomal STR loci of Huaxia™ Platinum kit with highly polymorphic in Han population can be used for paternity testing and individual identification. Compared with other 7 kits, it appears that Huaxia™ Platinum kit can provide more genetic information. Copyright© by the Editorial Department of Journal of Forensic Medicine

  7. A short history, principles, and types of ELISA, and our laboratory experience with peptide/protein analyses using ELISA.

    PubMed

    Aydin, Suleyman

    2015-10-01

    Playing a critical role in the metabolic homeostasis of living systems, the circulating concentrations of peptides/proteins are influenced by a variety of patho-physiological events. These peptide/protein concentrations in biological fluids are measured using various methods, the most common of which is enzymatic immunoassay EIA/ELISA and which guide the clinicians in diagnosing and monitoring diseases that inflict biological systems. All the techniques where enzymes are employed to show antigen-antibody reactions are generally referred to as enzymatic immunoassay EIA/ELISA method. Since the basic principles of EIA and ELISA are the same. The main objective of this review is to present an overview of the historical journey that had led to the invention of EIA/ELISA, an indispensible method for medical and research laboratories, types of ELISA developed after its invention [direct (the first ELISA method invented), indirect, sandwich and competitive methods], problems encountered during peptide/protein analyses (pre-analytical, analytical and post-analytical), rules to be followed to prevent these problems, and our laboratory experience of more than 15 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. Basic Teaching Kit on Consumer Advertising.

    ERIC Educational Resources Information Center

    Proctor and Gamble Co., Cincinnati, OH.

    This advertising kit was developed by Procter and Gamble in response to requests from teachers and consumer educators who asked for materials from business about business. The kit is not intended to cover the entire field of advertising. Rather, it centers on advertising as it is known and practiced by Procter and Gamble. The purpose of the kit is…

  9. Bovine trophectoderm cell lines induced from bovine fibroblasts with reprogramming factors

    USDA-ARS?s Scientific Manuscript database

    Bovine trophectoderm (TE) cells were induced [induced bovine trophectoderm-like (iBT)] from bovine fetal liver-derived fibroblasts, and other bovine fetal fibroblasts, after viral-vector transduction with either four or six reprogramming factors (RF), including POU5F1, KLF4, SOX2, C-MYC, SV40 large ...

  10. PubMed Central

    Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.

    1994-01-01

    A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645

  11. Toxin-neutralizing antibodies protect against Clostridium perfringens-induced necrosis in an intestinal loop model for bovine necrohemorrhagic enteritis.

    PubMed

    Goossens, Evy; Verherstraeten, Stefanie; Valgaeren, Bonnie R; Pardon, Bart; Timbermont, Leen; Schauvliege, Stijn; Rodrigo-Mocholí, Diego; Haesebrouck, Freddy; Ducatelle, Richard; Deprez, Piet R; Van Immerseel, Filip

    2016-06-13

    Bovine necrohemorrhagic enteritis is caused by Clostridium perfringens type A. Due to the rapid progress and fatal outcome of the disease, vaccination would be of high value. In this study, C. perfringens toxins, either as native toxins or after formaldehyde inactivation, were evaluated as possible vaccine antigens. We determined whether antisera raised in calves against these toxins were able to protect against C. perfringens challenge in an intestinal loop model for bovine necrohemorrhagic enteritis. Alpha toxin and perfringolysin O were identified as the most immunogenic proteins in the vaccine preparations. All vaccines evoked a high antibody response against the causative toxins, alpha toxin and perfringolysin O, as detected by ELISA. All antibodies were able to inhibit the activity of alpha toxin and perfringolysin O in vitro. However, the antibodies raised against the native toxins were more inhibitory to the C. perfringens-induced cytotoxicity (as tested on bovine endothelial cells) and only these antibodies protected against C. perfringens challenge in the intestinal loop model. Although immunization of calves with both native and formaldehyde inactivated toxins resulted in high antibody titers against alpha toxin and perfringolysin O, only antibodies raised against native toxins protect against C. perfringens challenge in an intestinal loop model for bovine necrohemorrhagic enteritis.

  12. Competitive Enzyme-Linked Immunosorbent Assay for Detection of Leptospira interrogans Serovar pomona Antibodies in Bovine Sera

    PubMed Central

    Surujballi, Om; Mallory, Maria

    2001-01-01

    A competitive enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody (M898) was developed for detection of bovine antibodies to Leptospira interrogans serovar pomona. This assay was evaluated using field sera (n = 190) with serovar pomona microscopic agglutination test (MAT) titers of ≥100 as the positive population (group A); field sera (n = 1,445) which were negative in the MAT (1:100 dilution) for serovar pomona (group B); and sera (from a specific-pathogen-free cattle herd [n = 210]) which were negative in the MAT (1:100 dilution) for serovars canicola, copenhageni, grippotyphosa, hardjo, pomona, and sejroe (group C). At the cutoff point recommended by receiver operating characteristic (ROC) curve analysis of the combined ELISA results of serum groups A, B, and C, the sensitivity and specificity values were 93.7 and 96.3%, respectively. The value for the area under this ROC curve was 0.977, indicating a high level of accuracy for the ELISA. Similar results were obtained from the analysis of the combined results of serum groups A and B and from the analysis of the combined results of serum groups A and C. PMID:11139193

  13. 77 FR 15847 - Bovine Spongiform Encephalopathy; Importation of Bovines and Bovine Products

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-16

    ...We are proposing to amend the regulations that govern the importation of animals and animal products to revise the conditions for the importation of live bovines and products derived from bovines with regard to bovine spongiform encephalopathy (BSE). We are proposing to base importation conditions on the inherent risk of BSE infectivity in specified commodities, as well as on the BSE risk status of the region from which the commodities originate. We are proposing to establish a system for classifying regions as to BSE risk that is consistent with the system employed by the World Organization for Animal Health (OIE), the international standard-setting organization for guidelines related to animal health. The conditions we are proposing for the importation of specified commodities are based on internationally accepted scientific literature and, except in a few instances, are consistent with guidelines set out in the OIE's Terrestrial Animal Health Code. We are also proposing to classify certain specified countries as to BSE risk and are proposing to remove BSE restrictions on the importation of cervids and camelids and products derived from such animals. We are proposing to make these amendments after conducting a thorough review of relevant scientific literature and a comprehensive evaluation of the issues and concluding that the proposed changes to the regulations would continue to guard against the introduction of BSE into the United States, while allowing the importation of additional animals and animal products into this country. In this document we are also affirming the position we took in removing the delay of applicability of certain provisions of the rule entitled ``Bovine Spongiform Encephalopathy; Minimal-Risk Regions and Importation of Commodities,'' published in the Federal Register on January 4, 2005 (70 FR 460-553). The delay of applicability was removed in a final rule entitled ``Bovine Spongiform Encephalopathy; Minimal-Risk Regions; Importation

  14. Comparison of the serological tests ICT and ELISA for the diagnosis of alveolar echinococcosis in France☆

    PubMed Central

    Knapp, Jenny; Sako, Yasuhito; Grenouillet, Frédéric; Bresson-Hadni, Solange; Richou, Carine; Gbaguidi-Haore, Houssein; Ito, Akira; Millon, Laurence

    2014-01-01

    Serological diagnosis of alveolar echinococcosis (AE) is a key element for efficient patient treatment management. A rapid immunochromatography test kit (ICT) using the recombinant Em18 antigen (rEm18) was recently developed. The aim of our study was to assess this test on a panel of sera from French patients with alveolar echinococcosis and control patients. In a blind test, a total of 112 serum samples were tested including samples of AE (n = 30), cystic echinococcosis [CE] (n = 15), and polycystic echinococcosis [PE] (n = 1). For the comparison, 66 sera from patients with hepatocarcinoma, fascioliasis, toxocariasis, Caroli’s disease, or autoimmune chronic active hepatitis were used. The diagnostic test sets we used were the rEm18-ICT and two validated ELISAs with rEm18 and Em2-Em18 antigens, respectively. For the ICT, 27/30 sera from AE patients, 4/15 sera from CE patients and the PE patient serum were positive. One serum from the control panel (toxocariasis) was positive for the ICT. The rEm18-ICT sensitivity (90.0%) and specificity (92.7%) for detection of Em18-specific antibodies confirmed it as a relevant tool for AE diagnosis. The rEm18-ELISA had a sensitivity of 86.7% and specificity of 91.5%, and the Em2-Em18-ELISA had a sensitivity of 96.7% and specificity of 87.8%. However, when AE patient sera are recorded as weak in intensity with the ICT, we recommend a double reading and use of a reference sample if the ICT is used for patient follow-up. PMID:25058754

  15. Comparison of the serological tests ICT and ELISA for the diagnosis of alveolar echinococcosis in France.

    PubMed

    Knapp, Jenny; Sako, Yasuhito; Grenouillet, Frédéric; Bresson-Hadni, Solange; Richou, Carine; Gbaguidi-Haore, Houssein; Ito, Akira; Millon, Laurence

    2014-01-01

    Serological diagnosis of alveolar echinococcosis (AE) is a key element for efficient patient treatment management. A rapid immunochromatography test kit (ICT) using the recombinant Em18 antigen (rEm18) was recently developed. The aim of our study was to assess this test on a panel of sera from French patients with alveolar echinococcosis and control patients. In a blind test, a total of 112 serum samples were tested including samples of AE (n = 30), cystic echinococcosis [CE] (n = 15), and polycystic echinococcosis [PE] (n = 1). For the comparison, 66 sera from patients with hepatocarcinoma, fascioliasis, toxocariasis, Caroli's disease, or autoimmune chronic active hepatitis were used. The diagnostic test sets we used were the rEm18-ICT and two validated ELISAs with rEm18 and Em2-Em18 antigens, respectively. For the ICT, 27/30 sera from AE patients, 4/15 sera from CE patients and the PE patient serum were positive. One serum from the control panel (toxocariasis) was positive for the ICT. The rEm18-ICT sensitivity (90.0%) and specificity (92.7%) for detection of Em18-specific antibodies confirmed it as a relevant tool for AE diagnosis. The rEm18-ELISA had a sensitivity of 86.7% and specificity of 91.5%, and the Em2-Em18-ELISA had a sensitivity of 96.7% and specificity of 87.8%. However, when AE patient sera are recorded as weak in intensity with the ICT, we recommend a double reading and use of a reference sample if the ICT is used for patient follow-up. © J. Knapp et al., published by EDP Sciences, 2014.

  16. c-KIT positive schistosomal urinary bladder carcinoma are frequent but lack KIT gene mutations.

    PubMed

    Shams, Tahany M; Metawea, Mokhtar; Salim, Elsayed I

    2013-01-01

    Urinary bladder squamous cell carcinoma (SCC), one of the most common neoplasms in Egypt, is attributed to chronic urinary infection with Schistosoma haematobium (Schistosomiasis). The proto-oncogene c-KIT, encoding a tyrosine kinase receptor and implicated in the development of a number of human malignancies, has not been studied so far in schistosomal urinary bladder SCCs. We therefore determined immunohistochemical (IHC) expression of c-KIT in paraffin sections from 120 radical cystectomies of SCCs originally obtained from the Pathology Department of Suez Canal University (Ismailia, Egypt). Each slide was evaluated for staining intensity where the staining extent of >10% of cells was considered positive. c-KIT overexpression was detected in 78.3% (94/120) of the patients, the staining extents in the tumor cells were 11-50% and >50% in 40 (42.6%) and 54 (57.4%) respectively. The positive cases had 14.9%, 63.8%, 21.3% as weak, moderate and strong intensity respectively. Patients with positive bilharzial ova had significantly higher c-KIT expression than patients without (95.2% vs. 38.9%, P=0.000). Mutation analysis of exons 9-13 was negative in thirty KIT positive cases. The high rate of positivity in SBSCC was one of the striking findings; However, CD117 may be a potential target for site specific immunotherapy to improve the outcome of this tumor.

  17. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  18. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  19. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  20. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  1. 21 CFR 868.1100 - Arterial blood sampling kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Arterial blood sampling kit. 868.1100 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1100 Arterial blood sampling kit. (a) Identification. An arterial blood sampling kit is a device, in kit form, used to obtain arterial blood samples...

  2. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  3. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  4. 21 CFR 870.1350 - Catheter balloon repair kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the balloon of a balloon catheter. The kit contains the materials, such as glue and balloons, necessary to...

  5. Mobile phone based ELISA (MELISA).

    PubMed

    Zhdanov, Arsenii; Keefe, Jordan; Franco-Waite, Luis; Konnaiyan, Karthik Raj; Pyayt, Anna

    2018-04-30

    Enzyme-linked immunosorbent assay (ELISA) is one of the most important technologies for biochemical analysis critical for diagnosis and monitoring of many diseases. Traditional systems for ELISA incubation and reading are expensive and bulky, thus cannot be used at point-of-care or in the field. Here, we propose and demonstrate a new miniature mobile phone based system for ELISA (MELISA). This system can be used to complete all steps of the assay, including incubation and reading. It weighs just 1 pound, can be fabricated at low cost, portable, and can transfer test results via mobile phone. We successfully demonstrated how MELISA can be calibrated for accurate measurements of progesterone and demonstrated successful measurements with the calibrated system. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Detection of Mycobacterium bovis infection in African buffaloes (Syncerus caffer) using QuantiFERON®-TB Gold (QFT) tubes and the Qiagen cattletype® IFN-gamma ELISA.

    PubMed

    Bernitz, Netanya; Clarke, Charlene; Roos, Eduard O; Goosen, Wynand J; Cooper, David; van Helden, Paul D; Parsons, Sven D C; Miller, Michele A

    2018-02-01

    African buffaloes (Syncerus caffer) are wildlife maintenance hosts of Mycobacterium bovis, the cause of bovine tuberculosis. Consequently, M. bovis infected buffaloes pose a transmission risk for cattle and other wildlife species. Previously, a modification to the Qiagen QuantiFERON ® -TB Gold (QFT) system, using QFT tubes and an in-house bovine interferon-gamma (IFN-γ) ELISA, was evaluated for the detection of M. bovis infection in buffaloes. Subsequently, Qiagen has developed a commercially available cattletype ® IFN-gamma ELISA for the detection of antigen-specific IFN-γ release in ruminants. The aim of this study was to investigate the use of QFT tubes and the cattletype ® IFN-gamma ELISA, in a cattletype IFN-γ release assay (IGRA), to detect M. bovis infection in African buffaloes. The test agreements between the cattletype IGRA, single comparative intradermal skin test (SCITT) and Bovigam ® 1G IGRA in two M. bovis-exposed buffalo populations (n = 134 and n = 92) were calculated and κ coefficients ranged from 0.65 (95% CI 0.48-0.82) to 0.86 (95% CI 0.72-0.99). Increasing the QFT incubation time in one M. bovis-exposed buffalo cohort (n = 92), from 20 to 40 h, had no effect on the cattletype IGRA test results. Inter-assay and intra-assay reproducibility determination for the cattletype IGRA produced coefficient of variations (CV) <9.1% and <1.7%, respectively. A total of 21/21 known M. bovis-unexposed buffaloes tested negative in the cattletype IGRA. Moreover, the cattletype IGRA test result values were significantly greater for 13 M. bovis culture-positive buffaloes compared with 14 M. bovis-exposed culture-negative (P < .01) and 21 M. bovis-unexposed (P < .001) buffaloes, respectively. These findings suggest that the combination of QFT tubes and the cattletype ® IFN-gamma ELISA is a promising new diagnostic assay for the detection of M. bovis infection in African buffaloes. However, further research is needed to evaluate the

  7. Enterocytozoon bieneusi in Bovine Viral Diarrhea Virus (BVDV) infected and noninfected cattle herds.

    PubMed

    Juránková, J; Kamler, M; Kovařčík, K; Koudela, B

    2013-02-01

    Enterocytozoon bieneusi known as a causative agent of opportunistic infections instigating diarrhoea in AIDS patients was identified also in a number of immunocompetent patients and in a wide range of animals, including cattle. In the present study we tested if the Bovine Viral Diarrhea Virus (BVDV), the most common pathogen underlying immunosuppressive Bovine Viral Diarrhoea (BVD), can enhance the occurrence of opportunistic infections with E. bieneusi in cattle. Six dairy farms were investigated using ELISA to detect antibodies against or antigens arising from BVDV in collected sera. A total of 240 individual faecal samples from four age groups were examined for the presence of E. bieneusi by nested PCR. Sequence analysis of six E. bieneusi positive samples revealed the presence of the genotype I of E. bieneusi, previously described in cattle. The hypothesis expecting higher prevalence of E. bieneusi in BVDV positive cattle herds was not confirmed in this study; however this is the first description about E. bieneusi in cattle in the Czech Republic. Copyright © 2012 Elsevier Ltd. All rights reserved.

  8. Residual bovine serum albumin (BSA) quantitation in vaccines using automated Capillary Western technology.

    PubMed

    Loughney, John W; Lancaster, Catherine; Ha, Sha; Rustandi, Richard R

    2014-09-15

    Bovine serum albumin (BSA) is a major component of fetal bovine serum (FBS), which is commonly used as a culture medium during vaccine production. Because BSA can cause allergic reactions in humans the World Health Organization (WHO) has set a guidance of 50 ng or less residual BSA per vaccine dose. Vaccine manufacturers are expected to develop sensitive assays to detect residual BSA. Generally, sandwich enzyme-linked immunosorbent assays (ELISA) are used in the industry to detect these low levels of BSA. We report the development of a new improved method for residual BSA detection using the SimpleWestern technology to analyze residual BSA in an attenuated virus vaccine. The method is based on automated Capillary Western and has linearity of two logs, >80% spike recovery (accuracy), intermediate precision of CV <15%, and LOQ of 5.2 ng/ml. The final method was applied to analyze BSA in four lots of bulk vaccine products and was used to monitor BSA clearance during vaccine process purification. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. FES kinase participates in KIT-ligand induced chemotaxis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Voisset, Edwige, E-mail: Edwige.Voisset@inserm.fr; Institut Paoli-Calmettes, Marseille; Universite de la Mediterranee, Aix-Marseille II

    2010-02-26

    FES is a cytoplasmic tyrosine kinase activated by several membrane receptors, originally identified as a viral oncogene product. We have recently identified FES as a crucial effector of oncogenic KIT mutant receptor. However, FES implication in wild-type KIT receptor function was not addressed. We report here that FES interacts with KIT and is phosphorylated following activation by its ligand SCF. Unlike in the context of oncogenic KIT mutant, FES is not involved in wild-type KIT proliferation signal, or in cell adhesion. Instead, FES is required for SCF-induced chemotaxis. In conclusion, FES kinase is a mediator of wild-type KIT signalling implicatedmore » in cell migration.« less

  10. 49 CFR 173.165 - Polyester resin kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Polyester resin kits. 173.165 Section 173.165... Polyester resin kits. (a) Except for transportation by aircraft, polyester resin kits consisting of a base... will not interact dangerously in the event of leakage. (b) For transportation by aircraft, polyester...

  11. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  12. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  13. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia conduction kit. 868.5140 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a) Identification. An anesthesia conduction kit is a device used to administer to a patient conduction, regional, or...

  14. [Evaluation of Wondfo Rapid Diagnostic Kit for detecting Plasmodium ovale and analysis of influencing factors].

    PubMed

    Feng, Tang; Jian-Xia, Tang; Feng, Lu; Sui, Xu; Ya-Ping, Gu; De-Sheng, Tong; Guo-Ding, Zhu; Hai-Yong, Hua; Hua-Yun, Zhou; Jun, Cao

    2016-03-21

    To evaluate the Wondfo Rapid Diagnostic Kit (Pf-LDH/Pan -pLDH) for detecting Plasmodium ovale and analyze the influence of parasitaemia, concentration and polymorphism of pLDH on the performances. A total of 100 blood samples from P. ovale patients confirmed by PCR were detected with the Wondfo Rapid Diagnostic Kit according to the manufacturers'instructions. The parasitaemia was determined by the microscopic examination. The concentration of pLDH was measured by ELISA tests. The LDH gene of P. ovale was amplified by PCR and sequenced. The influence of these three factors on the positive rate was analyzed. The overall positive rate of Wondfo Rapid Diagnostic Kit was 70.0% (70/100). The positive rate was 27.3% for the samples with parasitaemia ≤ 500 parasites/μl and reached 75.0%-75.4% when parasitaemia > 500 parasites/μl. The positive rate was 6.7% for samples with a low pLDH concentration ( A values ≤ 0.100) and reached 95.1%-100% at a high pLDH concentration ( A values > 0.100). The results of sequence analysis indicated that all the samples could be divided into 2 types, P. o. curtisi and P. o. wallikeri . The gene homology of LDH between 2 types was 97%. There were 24 single nucleotide polymorphism (s) (SNPs) between 2 types, while only 3 SNPs were non-synonymous mutations. The homology of LDH amino acid sequences between 2 types was 99%; only 3 amino acids were different. The positive rates for P. o. curtisi and P. o. wallikeri were 73.1% (38/52) and 66.7% (32/48) respectively; there was no statistically significant difference ( P > 0.05). The Wondfo Rapid Diagnostic Kit (Pf-LDH/Pan-pLDH) performs better than most of the similar products for the detection of P. ovale , and the positive rates are closely related to the parasitaemia and concentration of pLDH, while no related to the polymorphism of pLDH gene.

  15. Analysis of High-Throughput ELISA Microarray Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, Amanda M.; Daly, Don S.; Zangar, Richard C.

    Our research group develops analytical methods and software for the high-throughput analysis of quantitative enzyme-linked immunosorbent assay (ELISA) microarrays. ELISA microarrays differ from DNA microarrays in several fundamental aspects and most algorithms for analysis of DNA microarray data are not applicable to ELISA microarrays. In this review, we provide an overview of the steps involved in ELISA microarray data analysis and how the statistically sound algorithms we have developed provide an integrated software suite to address the needs of each data-processing step. The algorithms discussed are available in a set of open-source software tools (http://www.pnl.gov/statistics/ProMAT).

  16. An inter-laboratory comparative study of serological tools employed in the diagnosis of Besnoitia besnoiti infection in bovines.

    PubMed

    García-Lunar, P; Ortega-Mora, L M; Schares, G; Gollnick, N S; Jacquiet, P; Grisez, C; Prevot, F; Frey, C F; Gottstein, B; Alvarez-García, G

    2013-02-01

    Bovine besnoitiosis is considered an emerging chronic and debilitating disease in Europe. Many infections remain subclinical, and the only sign of disease is the presence of parasitic cysts in the sclera and conjunctiva. Serological tests are useful for detecting asymptomatic cattle/sub-clinical infections for control purposes, as there are no effective drugs or vaccines. For this purpose, diagnostic tools need to be further standardized. Thus, the aim of this study was to compare the serological tests available in Europe in a multi-centred study. A coded panel of 241 well-characterized sera from infected and non-infected bovines was provided by all participants (SALUVET-Madrid, FLI-Wusterhausen, ENV-Toulouse, IPB-Berne). The tests evaluated were as follows: an in-house ELISA, three commercial ELISAs (INGEZIM BES 12.BES.K1 INGENASA, PrioCHECK Besnoitia Ab V2.0, ID Screen Besnoitia indirect IDVET), two IFATs and seven Western blot tests (tachyzoite and bradyzoite extracts under reducing and non-reducing conditions). Two different definitions of a gold standard were used: (i) the result of the majority of tests ('Majority of tests') and (ii) the majority of test results plus pre-test information based on clinical signs ('Majority of tests plus pre-test info'). Relative to the gold standard 'Majority of tests', almost 100% sensitivity (Se) and specificity (Sp) were obtained with SALUVET-Madrid and FLI-Wusterhausen tachyzoite- and bradyzoite-based Western blot tests under non-reducing conditions. On the ELISAs, PrioCHECK Besnoitia Ab V2.0 showed 100% Se and 98.8% Sp, whereas ID Screen Besnoitia indirect IDVET showed 97.2% Se and 100% Sp. The in-house ELISA and INGEZIM BES 12.BES.K1 INGENASA showed 97.3% and 97.2% Se; and 94.6% and 93.0% Sp, respectively. IFAT FLI-Wusterhausen performed better than IFAT SALUVET-Madrid, with 100% Se and 95.4% Sp. Relative to the gold standard 'Majority of test plus pre-test info', Sp significantly decreased; this result was expected

  17. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 30 2010-07-01 2010-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  18. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 31 2011-07-01 2011-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  19. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 32 2013-07-01 2013-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  20. 40 CFR 745.88 - Recognized test kits.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 31 2014-07-01 2014-07-01 false Recognized test kits. 745.88 Section... Renovation § 745.88 Recognized test kits. (a) Effective June 23, 2008, EPA recognizes the test kits that have been determined by National Institute of Standards and Technology research to meet the negative...

  1. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  2. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  3. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  4. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  5. 21 CFR 880.5740 - Suction snakebite kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suction snakebite kit. 880.5740 Section 880.5740 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... Devices § 880.5740 Suction snakebite kit. (a) Identification. A suction snakebite kit is a device...

  6. The challenges of lean manufacturing implementation in kitting assembly

    NASA Astrophysics Data System (ADS)

    Fansuri, A. F. H.; Rose, A. N. M.; Nik Mohamed, N. M. Z.; Ahmad, H.

    2017-10-01

    Literature studies shows that lean manufacturing goes way back with the original founder Eli Whitney in year 1799. The main purpose of lean manufacturing is to identify and eliminate waste in production. The application of lean manufacturing can be carried out in any industrial processes with regards to the understanding of lean principles, theories and practices. Kitting is one of the important aspects in a successful production. The continuous supply of materials from store to production has to be systematic and able to achieve lean standard for it to be successful. The objective of this paper is to review the implementation of lean manufacturing in kitting assembly. Previous papers show that, the implementation of lean manufacturing in kitting assembly may be beneficial to the organization such as reduce in space occupancy, part shortages, lead time and manpower. Based on previous research, some industries may tend to change between kitting and line stocking which are due to lack of understanding when implementing kitting and causes longer lead time and materials overflow in store. With a proper understanding on what to kit, where to kit, how to kit, why to kit and who kits the material with a standardised process flow may ensure the success of kitting.

  7. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  8. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  9. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  10. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  11. 46 CFR 169.725 - First aid kit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false First aid kit. 169.725 Section 169.725 Shipping COAST... Control, Miscellaneous Systems, and Equipment § 169.725 First aid kit. Each vessel must carry an approved first aid kit, constructed and fitted in accordance with subpart 160.041 of this chapter. ...

  12. Co-purification of arrestin like proteins with alpha-enolase from bovine myocardial tissues and the possible role in heart diseases as an autoantigen

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mirshahi, M., E-mail: massoud.mirshahi@inserm.fr; Le Marchand, S.

    Aim: Previously, we reported that visual arrestin co-purified with glycolytic enzymes. The aim of this study was to analyze the co-purification of arrestin like proteins (ALP) in bovine cardiac tissues with enolases. Methods: The soluble extract of bovine myocardial tissues from different regions such as left and right atriums and ventricles of the bovine heart (n = 3) was analyzed by ACA-34 gel filtration, immuno-affinity column, SDS-PAGE, ELISA, western blot and a sandwich immune assay for quantification of ALP and sequence analysis. Results: We observed that; 1) The cardiac muscle contained a 50 kDa ALP at a concentration of 751 pg/mg of soluble proteinmore » extract, 2) ALP purified, by immunoaffinity, contained alpha-enolase of 48 kDa confirmed by protein sequence analysis; 3) Cardiomyocyte cells exposed to anti arrestin and anti enolase monoclonal antibodies showed decreased proliferation in vitro, 4) High level of autoantibodies were detected by ELISA (3.57% for arrestin and 9.12% for α-enolase) in serum of patients with infarcted heart disease. Conclusion: We suggest a possible interaction between ALP and alpha-enolases yielding a complex that may be involved in the induction of cardiac autoimmune diseases. - Highlights: • We examine a possible interaction between arrestin like protein and alpha-enolases in cardiomyocyte. • We demonstrated the effect of antibodies against arrestin and enolase on cardiomyocyte cell proliferation. • We suggest that this proteins complex may be involved in the induction of cardiac autoimmune diseases.« less

  13. Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  14. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 4 2012-10-01 2012-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  15. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  16. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 4 2014-10-01 2014-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  17. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 4 2013-10-01 2013-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  18. 46 CFR 108.707 - First aid kit.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false First aid kit. 108.707 Section 108.707 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.707 First aid kit. Each unit must have a first-aid kit approved by the Mine Safety...

  19. Planning Systems. SPEC Kit 13.

    ERIC Educational Resources Information Center

    Association of Research Libraries, Washington, DC. Office of Management Studies.

    This kit on planning systems updates a 1974 Management Studies Office Systems and Procedures Exchange Center (SPEC) kit in which developments in planning activities among Association of Research Libraries (ARL) were reviewed. At the time of the original study, in 1972, planning techniques and systems were a subject of much interest because rising…

  20. Association between bovine casein antibody and new onset schizophrenia among US military personnel.

    PubMed

    Niebuhr, David W; Li, Yuanzhang; Cowan, David N; Weber, Natalya S; Fisher, Jared A; Ford, Glen M; Yolken, Robert

    2011-05-01

    Schizophrenia is a pervasive neuropsychiatric disorder of uncertain etiology. Multiple studies have documented immune activation in individuals with schizophrenia. One antigen capable of inducing a prolonged immune response is bovine casein derived from ingested milk products. Increased levels of casein antibodies have been found in individuals with schizophrenia after diagnosis. This study was directed at determining the potential association between schizophrenia and pre-illness onset levels of immunoglobulin G (IgG) antibodies to bovine casein. Parallel analyses for casein antibody levels with bipolar disorder were included as comparison. Cases were service members who received medical discharges from the military with a schizophrenia diagnosis from 1992 to 2005. Serum specimens were selected for 855 cases and 1165 matched healthy controls. IgG antibodies to bovine whole-casein were measured by solid phase enzyme-linked immunosorbent assays (ELISAs). Hazard ratios (HR) were calculated to examine the associations of casein IgG level with risk of schizophrenia by time to diagnosis and by subjects' initial level. Increasing casein IgG antibody levels among those with a high initial level, drawn before diagnosis, was associated with an 18% increase in the hazard risk of schizophrenia per unit increase (value of low-positive standard) in IgG antibody levels (HR=1.18; 95% CI 1.04, 1.34). This is the first report to identify an association between the risk of schizophrenia and elevated antibodies to bovine casein prior to disease onset. Additional research is required to elucidate the complex genetic environmental interactions involved in the pathogenesis of schizophrenia and to identify potentially modifiable risk factors. Published by Elsevier B.V.

  1. Glider kits cut truck ownership costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smiley, C.H.

    1983-06-01

    A glider kit consists of a new truck without the power train, with the customer supplying the engine, transmission, clutch, driveline and rear axles for mounting in a new frame and cab complete with steering axle, wiring harnesses, exhaust system and cooling system. Glider kits have long been regarded as a cost effective means of replacing accident or fire damaged late model vehicles. The financial advantages, assembly and remanufacturing are discussed. Points out that at a basic cost about one third of a new truck, a glider kit offers lower cost of borrowed capital, tax savings, and elimination of highmore » maintenance and downtime costs. The paper concludes that use of glider kits as an alternative to major repair or reconditioning or outright replacement of coal haulers presents some interesting options.« less

  2. Look Around You, Kit I.

    ERIC Educational Resources Information Center

    1971

    Developing pupils' awareness of their environment, learning to distinguish between what is pleasant and unpleasant, and examining acts of man to determine which are destructive and which are in harmony with nature are the purposes of Scholastic's Earth Corps Environmental Study Kits for grades 1-6. This kit is designed to help the child develop…

  3. First Follow Nature, Kit II.

    ERIC Educational Resources Information Center

    1971

    Developing pupils' awareness of their environment, learning to distinguish between what is pleasant and unpleasant, and examining acts of man to determine which are destructive and which are in harmony with nature are the purposes of Scholastic's Earth Corps Environmental Study Kits for Grades 1-6. This kit explores in depth the reasons some…

  4. Antibody-independent identification of bovine milk-derived peptides in breast-milk.

    PubMed

    Picariello, Gianluca; Addeo, Francesco; Ferranti, Pasquale; Nocerino, Rita; Paparo, Lorella; Passariello, Annalisa; Dallas, David C; Robinson, Randall C; Barile, Daniela; Canani, Roberto Berni

    2016-08-10

    Exclusively breast-fed infants can exhibit clear signs of IgE or non IgE-mediated cow's milk allergy. However, the definite characterization of dietary cow's milk proteins (CMP) that survive the maternal digestive tract to be absorbed into the bloodstream and secreted into breast milk remains missing. Herein, we aimed at assessing possible CMP-derived peptides in breast milk. Using high performance liquid chromatography (HPLC)-high resolution mass spectrometry (MS), we compared the peptide fraction of breast milk from 12 donors, among which 6 drank a cup of milk daily and 6 were on a strict dairy-free diet. We identified two bovine β-lactoglobulin (β-Lg, 2 out 6 samples) and one αs1-casein (1 out 6 samples) fragments in breast milk from mothers receiving a cup of bovine milk daily. These CMP-derived fragments, namely β-Lg (f42-54), (f42-57) and αs1-casein (f180-197), were absent in milk from mothers on dairy-free diet. In contrast, neither intact nor hydrolyzed β-Lg was detected by western blot and competitive ELISA in any breast milk sample. Eight additional bovine milk-derived peptides identified by software-assisted MS were most likely false positive. The results of this study demonstrate that CMP-derived peptides rather than intact CMP may sensitize or elicit allergic responses in the neonate through mother's milk. Immunologically active peptides from the maternal diet could be involved in priming the newborn's immune system, driving a tolerogenic response.

  5. Pathologic Stimulus Determines Lineage Commitment of Cardiac C-kit+ Cells.

    PubMed

    Chen, Zhongming; Zhu, Wuqiang; Bender, Ingrid; Gong, Wuming; Kwak, Il-Youp; Yellamilli, Amritha; Hodges, Thomas J; Nemoto, Natsumi; Zhang, Jianyi; Garry, Daniel J; van Berlo, Jop H

    2017-12-12

    Although cardiac c-kit + cells are being tested in clinical trials, the circumstances that determine lineage differentiation of c-kit + cells in vivo are unknown. Recent findings suggest that endogenous cardiac c-kit + cells rarely contribute cardiomyocytes to the adult heart. We assessed whether various pathological stimuli differentially affect the eventual cell fates of c-kit + cells. We used single-cell sequencing and genetic lineage tracing of c-kit + cells to determine whether various pathological stimuli would result in different fates of c-kit + cells. Single-cell sequencing of cardiac CD45 - c-kit + cells showed innate heterogeneity, indicative of the existence of vascular and mesenchymal c-kit + cells in normal hearts. Cardiac pressure overload resulted in a modest increase in c-kit-derived cardiomyocytes, with significant increases in the numbers of endothelial cells and fibroblasts. Doxorubicin-induced acute cardiotoxicity did not increase c-kit-derived endothelial cell fates but instead induced cardiomyocyte differentiation. Mechanistically, doxorubicin-induced DNA damage in c-kit + cells resulted in expression of p53. Inhibition of p53 blocked cardiomyocyte differentiation in response to doxorubicin, whereas stabilization of p53 was sufficient to increase c-kit-derived cardiomyocyte differentiation. These results demonstrate that different pathological stimuli induce different cell fates of c-kit + cells in vivo. Although the overall rate of cardiomyocyte formation from c-kit + cells is still below clinically relevant levels, we show that p53 is central to the ability of c-kit + cells to adopt cardiomyocyte fates, which could lead to the development of strategies to preferentially generate cardiomyocytes from c-kit + cells. © 2017 American Heart Association, Inc.

  6. Bovine respiratory disease model based on dual infections with infection with bovine viral diarrhea virus and bovine corona virus

    USDA-ARS?s Scientific Manuscript database

    Bovine respiratory disease complex (BRDC) is the leading cause of economic loss in the U.S. cattle industry. BRDC likely results from simultaneous or sequential infections with multiple pathogens including both viruses and bacteria. Bovine viral diarrhea virus (BVDV) and bovine corona virus (BoCV...

  7. Travel Medical Kit.

    PubMed

    Terry, Anne C; Haulman, N Jean

    2016-03-01

    "The traveler's medical kit is an essential tool for both the novice and expert traveler. It is designed to treat travel-related illness and injury and to ensure preexisting medical conditions are managed appropriately. Travelers are at increased risk for common gastrointestinal issues during travel. Respiratory illnesses make up approximately 8% of the ailments present in returned international travelers. Approximately 12% of travelers experience a travel-related skin condition. First aid treatment for minor injuries is essential to all travel medical kits. The complexity ranges from a small, simple case for the urban traveler to a larger, extensive case for wilderness travel." Copyright © 2016 Elsevier Inc. All rights reserved.

  8. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 6 2012-10-01 2012-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  9. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  10. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 6 2013-10-01 2013-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  11. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 6 2011-10-01 2011-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  12. 46 CFR 160.061-4 - Kit assembly.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 6 2014-10-01 2014-10-01 false Kit assembly. 160.061-4 Section 160.061-4 Shipping COAST... Kit assembly. (a) Preparation of items. The items shall be prepared for packing into the kit as... assembly 1, 10, 11, 12, 13, 14, 15, 16, 17, 23, 24 None. 3, 4, 5, 6, 7, 18, 19, 21, 22 Insert in a...

  13. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  14. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  15. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  16. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  17. 21 CFR 880.5960 - Lice removal kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... § 880.5960 Lice removal kit. (a) Identification. The lice removal kit is a comb or comb-like device intended to remove and/or kill lice and nits from head and body hair. It may or may not be battery operated... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Lice removal kit. 880.5960 Section 880.5960 Food...

  18. Taming C-terminal peptides of Staphylococcus aureus leukotoxin M for B-cell response: Implication in improved subclinical bovine mastitis diagnosis and protective efficacy in vitro.

    PubMed

    Padmaja, Radhakrishnan Jayasree; Halami, Prakash Motiram

    2016-09-01

    Leukotoxin M/F'-PV (LukM/F'-PV) produced by bovine mastitis causing Staphylococcus aureus structurally comprises three domains, the β-sandwich, rim and stem domain. The rim and stem domains interacting with target cell membrane lipid rafts contributes to the virulent trait of the toxin. In the present study, two facts were hypothesized that neutralization of these domains will ebb LukM/F'-PV leukotoxicity. Secondly, the neutralizing antibodies can improve the leukotoxin detection sensitivity in bovine mastitis milk samples. The in silico mapping of S. aureus LukM C-termini comprising these domains predicted seven linear B-cell antigenic epitopes. The immune response of C-terminal truncated recombinant peptides rCtM19 (19 kDa; near carboxy-terminal) having four epitopes and rCtM15 (15 kDa; C-terminal) with three epitopes were evaluated for their diagnostic and neutralization potential. Anti-rCtM19 and anti-rCtM15 antibodies with enhanced immunogenicity had the most striking outcome in IgG-ELISA for detecting native determinants of leukotoxin. For the obtained ELISA values, ROC curve inferred a cut-off score of >0.102 OD405. The assay sensitivity in the range of 90-96% along with 100% specificity and AUC of 0.93-0.98 categorized subclinical and clinical from healthy bovine milk samples. As observed through in vitro neutralization and LDH assays, C-terminus specific antibodies (1:42 titer) deactivating leukotoxicity abolished LukM from interacting with lipid bilayer and LukF for forming pores on bovine neutrophil membrane. As a proof of concept, it was proved that peptide antibodies can be a more specific serodiagnostic and passive therapeutic molecules. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. [Efficient extraction of transmembrane proteins using ProteoExtract Transmembrane Protein Extraction Kit].

    PubMed

    Błachnio, Karina

    2010-01-01

    Detergents commonly used for solubilization of membrane proteins may be ionic or non-ionic. Exposing membrane proteins to detergents, however, can adversely affect their native structure, which can be a major hindrance for functional studies. This is especially true for proteins with multiple transmembrane domains. The ProteoExtract Transmembrane Protein Extraction Kit (TM-PEK), offered by Merck, provides a detergent-free novel reagents to enable the mild and efficient extraction of proteins containing seven transmembrane domains, such as GPCRs (G-Protein Coupled Receptors) e.g.: Frizzled-4 and CELSR-3, from mammalian cells. The fraction enriched in transmembrane proteins using TM-PEK is directly compatible with enzyme assays, non-denaturing gel electrophoresis, 1- and 2-D SDS-PAGE, MS analysis, Western blotting, immunoprecipitation and ELISA. Unlike many alternatives, TM-PEK extraction procedure does not require sonication, extended rigorous vortexing, ultracentrifugation, or incubation of samples at elevated temperatures--thus minimizing the risk of post-extraction degradation or modifications.

  20. Assessment of an ELISA Laboratory Exercise

    ERIC Educational Resources Information Center

    Robinson, David L.; Lau, Joann M.

    2012-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a powerful immunological technique for quantifying small amounts of compounds and has been used in research and clinical settings for years. Although there are laboratory exercises developed to introduce the ELISA technique to students, their ability to promote student learning has not been…

  1. Psychometric Properties of the Concept Assessment Kit-Conservation.

    ERIC Educational Resources Information Center

    Lehnert, Linda; And Others

    1986-01-01

    This study investigated the psychometric properties of the Educational and Industrial Testing Service Concept Assessment Kit-Conservation (EITS Kit). Presented are an overview of the concept of conservation, a description of the EITS Kit, and results of the study. (MT)

  2. Considerable variation in the concentration of osteopontin in human milk, bovine milk, and infant formulas.

    PubMed

    Schack, L; Lange, A; Kelsen, J; Agnholt, J; Christensen, B; Petersen, T E; Sørensen, E S

    2009-11-01

    Osteopontin (OPN) is a multifunctional bioactive protein that is implicated in numerous biological processes such as bone remodeling, inhibition of ectopic calcification, and cellular adhesion and migration, as well as several immune functions. Osteopontin has cytokine-like properties and is a key factor in the initiation of T helper 1 immune responses. Osteopontin is present in most tissues and body fluids, with the highest concentrations being found in milk. In the present study, ELISA for human and bovine milk OPN were developed and OPN concentration in human breast milk, bovine milk, and infant formulas was measured and compared. The OPN concentration in human milk was measured to approximately 138 mg/L, which corresponds to 2.1% (wt/wt) of the total protein in human breast milk. This is considerably higher than the corresponding OPN concentrations in bovine milk (approximately 18 mg/L) and infant formulas (approximately 9 mg/L). Moreover, bovine milk OPN is shown to induce the expression of the T helper 1 cytokine IL-12 in cultured human lamina propria mononuclear cells isolated from intestinal biopsies. Finally, the OPN concentration in plasma samples from umbilical cords, 3-mo-old infants, and pregnant and nonpregnant adults was measured. The OPN level in plasma from 3-mo-old infants and umbilical cords was found to be 7 to 10 times higher than in adults. Thus, the high levels of OPN in milk and infant plasma suggest that OPN is important to infants and that ingested milk OPN is likely to induce cytokine production in neonate intestinal immune cells.

  3. Evaluating concentration estimation errors in ELISA microarray experiments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daly, Don S.; White, Amanda M.; Varnum, Susan M.

    Enzyme-linked immunosorbent assay (ELISA) is a standard immunoassay to predict a protein concentration in a sample. Deploying ELISA in a microarray format permits simultaneous prediction of the concentrations of numerous proteins in a small sample. These predictions, however, are uncertain due to processing error and biological variability. Evaluating prediction error is critical to interpreting biological significance and improving the ELISA microarray process. Evaluating prediction error must be automated to realize a reliable high-throughput ELISA microarray system. Methods: In this paper, we present a statistical method based on propagation of error to evaluate prediction errors in the ELISA microarray process. Althoughmore » propagation of error is central to this method, it is effective only when comparable data are available. Therefore, we briefly discuss the roles of experimental design, data screening, normalization and statistical diagnostics when evaluating ELISA microarray prediction errors. We use an ELISA microarray investigation of breast cancer biomarkers to illustrate the evaluation of prediction errors. The illustration begins with a description of the design and resulting data, followed by a brief discussion of data screening and normalization. In our illustration, we fit a standard curve to the screened and normalized data, review the modeling diagnostics, and apply propagation of error.« less

  4. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  5. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 19 Customs Duties 1 2011-04-01 2011-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  6. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 19 Customs Duties 1 2013-04-01 2013-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  7. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 19 Customs Duties 1 2012-04-01 2012-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  8. 19 CFR 122.132 - Sealing of aircraft liquor kits.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Sealing of aircraft liquor kits. 122.132 Section... OF THE TREASURY AIR COMMERCE REGULATIONS Aircraft Liquor Kits § 122.132 Sealing of aircraft liquor kits. (a) Sealing required. Aircraft liquor kits shall be sealed on board the aircraft by crewmembers...

  9. Standardization of a latex agglutination test for coproantigen detection of Fasciola sp. in bovine cattle stool.

    PubMed

    Orejarena Ávila, Lina Paola; Inguilan Benavides, Erika Marcela; Padilla Sanabria, Leonardo; Recalde-Reyes, Delia Piedad; Rodríguez-Salazar, Carlos Andrés; Castaño-Osorio, Jhon Carlos

    2018-03-01

    Fasciolosis is a zoonotic parasitic disease, which affects humans and animals; diagnosed through noncommercial immunoassay tests that cannot be used on the field. Thereby, establishing the optimal conditions to develop a latex agglutination technique with IgG and IgM antibodies directed against excretion/secretion antigens of Fasciola sp. is a priority. Latex particles were sensitized with IgG and IgM antibodies directed against excretion/secretion antigens of Fasciola sp. The specificity of the antibodies was determined against antigens of different helminths and protozoa; the sensitivity and specificity of the test was evaluated against a previously standardized direct ELISA. The coupling rates of the IgG and IgM antibodies were 85.77 and 100%, respectively. The minimum detectable concentration of Fasciola sp. excretion/secretion antigens, diluted in a phosphate-buffered saline, was 1.589 mg/mL(IgG) and 0.158 mg/mL(IgM) and for the antigens incorporated in the bovine cattle stool it was 3.178 mg/mL(IgG) and 1.589 mg/mL(IgM). The test showed crossed reaction against Giardia sp., and Cryptosporidium sp. antigens. Agreement of the IgG and IgM latex test against the ELISA test was of 78.78 and 96.96%, respectively; the specificity found was of 100% for both tests and sensitivity was 78.79% (IgG) and 96.97% (IgM). This work standardized the latex agglutination technique to detect Fasciola sp. antigens in bovine cattle stool.

  10. Novel sensitive monoclonal antibody based competitive enzyme-linked immunosorbent assay for the detection of raw and processed bovine beta-casein

    PubMed Central

    Castillo, Daniela S.

    2017-01-01

    Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention. PMID:28759641

  11. Novel sensitive monoclonal antibody based competitive enzyme-linked immunosorbent assay for the detection of raw and processed bovine beta-casein.

    PubMed

    Castillo, Daniela S; Cassola, Alejandro

    2017-01-01

    Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention.

  12. Culture Kits for the Elementary Classroom.

    ERIC Educational Resources Information Center

    Hickey, M. Gail

    1997-01-01

    Outlines an instructional unit where students construct culture kits illustrating a specific culture. Culture kits are constructed out of realia and other material including maps, travel brochures, photographs, newspapers, souvenirs, and other items. Discusses collecting these items and possible multicultural applications. (MJP)

  13. Genetic lineage tracing identifies in situ Kit-expressing cardiomyocytes

    PubMed Central

    Liu, Qiaozhen; Yang, Rui; Huang, Xiuzhen; Zhang, Hui; He, Lingjuan; Zhang, Libo; Tian, Xueying; Nie, Yu; Hu, Shengshou; Yan, Yan; Zhang, Li; Qiao, Zengyong; Wang, Qing-Dong; Lui, Kathy O; Zhou, Bin

    2016-01-01

    Cardiac cells marked by c-Kit or Kit, dubbed cardiac stem cells (CSCs), are in clinical trials to investigate their ability to stimulate cardiac regeneration and repair. These studies were initially motivated by the purported cardiogenic activity of these cells. Recent lineage tracing studies using Kit promoter to drive expression of the inducible Cre recombinase showed that these CSCs had highly limited cardiogenic activity, inadequate to support efficient cardiac repair. Here we reassess the lineage tracing data by investigating the identity of cells immediately after Cre labeling. Our instant lineage tracing approach identifies Kit-expressing cardiomyocytes, which are labeled immediately after tamoxifen induction. In combination with long-term lineage tracing experiments, these data reveal that the large majority of long-term labeled cardiomyocytes are pre-existing Kit-expressing cardiomyocytes rather than cardiomyocytes formed de novo from CSCs. This study presents a new interpretation for the contribution of Kit+ cells to cardiomyocytes and shows that Kit genetic lineage tracing over-estimates the cardiogenic activity of Kit+ CSCs. PMID:26634606

  14. Epidemiology of bovine brucellosis in Costa Rica: Lessons learned from failures in the control of the disease.

    PubMed

    Hernández-Mora, Gabriela; Ruiz-Villalobos, Nazareth; Bonilla-Montoya, Roberto; Romero-Zúniga, Juan-José; Jiménez-Arias, Julio; González-Barrientos, Rocío; Barquero-Calvo, Elías; Chacón-Díaz, Carlos; Rojas, Norman; Chaves-Olarte, Esteban; Guzmán-Verri, Caterina; Moreno, Edgardo

    2017-01-01

    Brucellosis, caused by Brucella abortus is a major disease of cattle and a zoonosis. In order to estimate the bovine brucellosis prevalence in Costa Rica (CR), a total 765 herds (13078 bovines) from six regions of CR were randomly sampled during 2012-2013. A non-random sample of 7907 herds (532199 bovines) of the six regions, arriving for diagnoses during 2014-2016 to the Costa Rican Animal Health Service was also studied. The prevalence estimated by Rose Bengal test (RBT) ranged from 10.5%-11.4%; alternatively, the prevalence estimated by testing the RBT positives in iELISA, ranged from 4.1%-6.0%, respectively. However, cattle in CR are not vaccinated with B. abortus S19 but with RB51 (vaccination coverage close to 11%), and under these conditions the RBT displays 99% specificity and 99% sensitivity. Therefore, the RBT herd depicted in the random analysis stands as a feasible assessment and then, the recommended value in case of planning an eradication program in CR. Studies of three decades reveled that bovine brucellosis prevalence has increased in CR. B. abortus was identified by biochemical and molecular studies as the etiological agent of bovine brucellosis. Multiple locus variable-number tandem repeat analysis-16 revealed four B. abortus clusters. Cluster one and three are intertwined with isolates from other countries, while clusters two and four have only representatives from CR. Cluster one is widely distributed in all regions of the country and may be the primary B. abortus source. The other clusters seem to be restricted to specific areas in CR. The implications of our findings, in relation to the control of the disease in CR, are critically discussed.

  15. Performance of Commercial Enzyme-Linked Immunosorbent Assays for Detection of Antibodies to Bordetella pertussis▿

    PubMed Central

    Riffelmann, M.; Thiel, K.; Schmetz, J.; Wirsing von Koenig, C. H.

    2010-01-01

    Measuring antibodies to Bordetella pertussis antigens is mostly done by enzyme-linked immunosorbent assays (ELISAs). We compared the performance of ELISA kits that were commercially available in Germany. Eleven measured IgG antibodies, and nine measured IgA antibodies. An in-house ELISA with purified antigens served as a reference method. Samples included two WHO reference preparations, the former Food and Drug Administration (FDA)/Center for Biologics Evaluation and Research (CBER) reference preparations, serum samples from patients with clinically suspected pertussis, and serum samples from patients having received a combined tetanus, diphtheria, and pertussis (Tdap) vaccination. Kits using pertussis toxin (PT) as an antigen showed linearity compared to the WHO Reference preparation (r2 between 0.82 and 0.99), and these kits could quantify antibodies according to the reference preparation. ELISA kits using mixed antigens showed no linear correlation to the reference preparations. Patient results were compared to results of in-house ELISAs using a dual cutoff of either ≥100 IU/ml anti-PT IgG or ≥40 IU/ml anti-PT IgG together with ≥12 IU/ml anti-PT IgA. The sensitivities of kits measuring IgG antibodies ranged between 0.84 and 1.00. The specificities of kits using PT as an antigen were between 0.81 and 0.93. The specificities of kits using mixed antigens were between 0.51 and 0.59 and were thus not acceptable. The sensitivities of kits measuring IgA antibodies ranged between 0.53 and 0.73, and the specificities were between 0.67 and 0.94, indicating that IgA antibodies may be of limited diagnostic value. Our data suggest that ELISAs should use purified PT as an antigen and be standardized to the 1st International Reference preparation. PMID:20943873

  16. Monitoring the bulk milk antibody response to bovine viral diarrhea in dairy herds vaccinated with inactivated vaccines.

    PubMed

    Gonzalez, A M; Arnaiz, I; Eiras, C; Camino, F; Sanjuán, M L; Yus, E; Diéguez, F J

    2014-01-01

    This study was designed to determine long-term responses in dairy herds after vaccination with 1 of 3 inactivated bovine viral diarrhea virus (BVDV) vaccines with regard to antibodies against p80 protein in bulk tank milk samples, as detected by ELISA. In the present study, 29 dairy herds were vaccinated with Bovilis BVD (MSD Animal Health, Milton Keynes, UK), 11 with Hiprabovis Balance (Laboratorios Hipra, Amer, Spain), and 9 with Pregsure BVD (Zoetis, Florham Park, NJ). In these herds, bulk tank milk samples were collected and examined at the time of the first vaccination and every 6 mo during a 3-yr period. Samples were analyzed with a commercial ELISA test for the p80 protein of BVDV. The results demonstrated that vaccination affected the level of antibodies against p80. Hence, vaccination status should be taken into consideration when interpreting bulk tank milk antibody tests. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  17. Postabsorptive hyperglucagonemia in patients with type 2 diabetes mellitus analyzed with a novel enzyme-linked immunosorbent assay.

    PubMed

    Matsuo, Toshihiro; Miyagawa, Jun-Ichiro; Kusunoki, Yoshiki; Miuchi, Masayuki; Ikawa, Takashi; Akagami, Takafumi; Tokuda, Masaru; Katsuno, Tomoyuki; Kushida, Akira; Inagaki, Takashi; Namba, Mitsuyoshi

    2016-05-01

    The aims of the present study were to investigate the performance of a novel sandwich enzyme-linked immunosorbent assay (ELISA) for measuring glucagon (1-29) with monoclonal antibodies against both the C- and N-terminal regions of glucagon (1-29), and to analyze the differences in plasma levels and responses of glucagon (1-29) to oral glucose loading in normal glucose tolerance (NGT) subjects and patients with type 2 diabetes mellitus. The cross-reactivity against proglucagon fragments using the ELISA kit and two types of conventional radioimmunoassay (RIA) kits was evaluated. A 75-g oral glucose tolerance test was carried out with NGT subjects and patients with type 2 diabetes mellitus, and the glucagon (1-29) concentration was measured using three types of kit. The ELISA kit clearly had the lowest cross-reactivity against miniglucagon (19-29) and glicentin (1-61). The oral glucose tolerance test was carried out with 30 NGT and 17 patients with type 2 diabetes mellitus. The glucagon (1-29) levels measured by the ELISA kit after glucose loading were significantly higher at all time-points in the type 2 diabetes mellitus group than in the NGT group. However, the glucagon (1-29) levels measured by one RIA kit were significantly higher in the NGT group, and those measured with the other RIA kit were approximately the same among the groups. The novel sandwich ELISA accurately determines plasma glucagon (1-29) concentrations with much less cross-reactivity against other proglucagon fragments than conventional RIA kits.

  18. Discovery of amido-benzisoxazoles as potent c-Kit inhibitors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kunz, Roxanne K.; Rumfelt, Shannon; Chen, Ning

    2010-01-12

    Deregulation of the receptor tyrosine kinase c-Kit is associated with an increasing number of human diseases, including certain cancers and mast cell diseases. Interference of c-Kit signaling with multi-kinase inhibitors has been shown clinically to successfully treat gastrointestinal stromal tumors and mastocytosis. Targeted therapy of c-Kit activity may provide therapeutic advantages against off-target effects for non-oncology applications. A new structural class of c-Kit inhibitors is described, including in vitro c-Kit potency, kinase selectivity, and the observed binding mode.

  19. Personal Computer-less (PC-less) Microcontroller Training Kit

    NASA Astrophysics Data System (ADS)

    Somantri, Y.; Wahyudin, D.; Fushilat, I.

    2018-02-01

    The need of microcontroller training kit is necessary for practical work of students of electrical engineering education. However, to use available training kit not only costly but also does not meet the need of laboratory requirements. An affordable and portable microcontroller kit could answer such problem. This paper explains the design and development of Personal Computer Less (PC-Less) Microcontroller Training Kit. It was developed based on Lattepanda processor and Arduino microcontroller as target. The training kit equipped with advanced input-output interfaces that adopted the concept of low cost and low power system. The preliminary usability testing proved this device can be used as a tool for microcontroller programming and industrial automation training. By adopting the concept of portability, the device could be operated in the rural area which electricity and computer infrastructure are limited. Furthermore, the training kit is suitable for student of electrical engineering student from university and vocational high school.

  20. Construction, expression, purification and biotin labeling of a single recombinant multi-epitope antigen for double-antigen sandwich ELISA to detect hepatitis C virus antibody.

    PubMed

    He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu

    2011-08-01

    Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.

  1. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  2. YourSELF. Middle School Nutrition Education Kit [Multimedia].

    ERIC Educational Resources Information Center

    Department of Agriculture, Washington, DC.

    This multimedia kit provides information and materials for teaching nutrition to middle school students (grades 7 and 8). The kit supports schools' efforts to make school meals healthier and more appealing to students. The materials provide information about the relationships between food, nutrition, growth, and health. The kit speaks directly to…

  3. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  4. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  5. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  6. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Partially fabricated denture kit. 872.3600 Section... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3600 Partially fabricated denture kit. (a) Identification. A partially fabricated denture kit is a device composed of connected preformed teeth that is...

  7. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... requirements of subpart B of this part and may not exceed 30 kg (66 pounds) gross weight; (5) Except for Carbon... kits must include sufficient absorbent material to completely absorb the contents of any liquid...

  8. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... requirements of subpart B of this part and may not exceed 30 kg (66 pounds) gross weight; (5) Except for Carbon... kits must include sufficient absorbent material to completely absorb the contents of any liquid...

  9. 49 CFR 173.161 - Chemical kits and first aid kits.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... requirements of subpart B of this part and may not exceed 30 kg (66 pounds) gross weight; (5) Except for Carbon... kits must include sufficient absorbent material to completely absorb the contents of any liquid...

  10. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  11. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  12. 10 CFR 429.33 - Ceiling fan light kits.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Ceiling fan light kits. 429.33 Section 429.33 Energy... COMMERCIAL AND INDUSTRIAL EQUIPMENT Certification § 429.33 Ceiling fan light kits. (a) Sampling plan for selection of units for testing. (1) The requirements of § 429.11 are applicable to ceiling fan light kits...

  13. The Fluid Dynamics Demo Kit: Part I

    NASA Astrophysics Data System (ADS)

    Flack, Karen; Underhill, Patrick; Prestridge, Kathy

    2012-11-01

    The goal of this project is to develop a fluid dynamics demonstration/experiment kit that can be used by professors and graduate students at high school outreach events. The demonstrations in the kit will be easy to use and true crowd pleasers in order to inspire understanding and pique curiosity about the physics of flow. The kits will be inexpensive, containing readily available materials so that teachers can duplicate the demonstrations and experiments. The kits will be left with the teachers as a gift from the American Physics Society. The experiments and demonstrations cover the concepts of conservation of mass, momentum, and energy, Bernoulli's equation, frictional losses and the ideal gas law. For each experiment, the teachers will receive presentation material, access to instructional videos, plus a worksheet that can be used in a high school physics classroom. This kit has been developed through the efforts of the APS-DFD Mentoring and Outreach Committee and has received funding from the APS-DFD. Work funded by the APS-DFD.

  14. Orbital Maneuvering Vehicle (OMV) remote servicing kit

    NASA Technical Reports Server (NTRS)

    Brown, Norman S.

    1988-01-01

    With the design and development of the Orbital Maneuvering Vehicle (OMV) progressing toward an early 1990 initial operating capability (IOC), a new era in remote space operations will evolve. The logical progression to OMV front end kits would make available in situ satellite servicing, repair, and consummables resupply to the satellite community. Several conceptual design study efforts are defining representative kits (propellant tanks, debris recovery, module servicers); additional focus must also be placed on an efficient combination module servicer and consummables resupply kit. A remote servicer kit of this type would be designed to perform many of the early maintenance/resupply tasks in both nominal and high inclination orbits. The kit would have the capability to exchange Orbital Replacement Units (ORUs), exchange propellant tanks, and/or connect fluid transfer umbilicals. Necessary transportation system functions/support could be provided by interfaces with the OMV, Shuttle (STS), or Expendable Launch Vehicle (ELV). Specific remote servicer kit designs, as well as ground and flight demonstrations of servicer technology are necessary to prepare for the potential overwhelming need. Ground test plans should adhere to the component/system/breadboard test philosophy to assure maximum capability of one-g testing. The flight demonstration(s) would most likely be a short duration, Shuttle-bay experiment to validate servicer components requiring a micro-g environment.

  15. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  16. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  17. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  18. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  19. 33 CFR 144.01-30 - First-aid kit.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false First-aid kit. 144.01-30 Section...) OUTER CONTINENTAL SHELF ACTIVITIES LIFESAVING APPLIANCES Manned Platforms § 144.01-30 First-aid kit. On each manned platform a first-aid kit approved by the Commandant or the U.S. Bureau of Mines shall be...

  20. Glider kits cut truck costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1984-02-01

    Trucks used for the delivery of coal have a relatively limited life because they must be specified for somewhat less than brute strength in order to achieve maximum payload within existing weight and length limitations. The major drive train components such as engine, transmission, and drive axles can last longer if rebuilt or remanufactured periodically. For that reason glider kits and other truck components ready for the installation of the drive chain are becoming increasingly popular. These kits have been available for many years, but were regarded only as a means of salvaging late model wrecks or burned trucks. Theirmore » recent acceptance as a means of periodic fleet updating is built around the low cost and immediate availability of remanufactured major components. The cost advantages in using these glider kits are discussed.« less

  1. Radotinib induces high cytotoxicity in c-KIT positive acute myeloid leukemia cells.

    PubMed

    Heo, Sook-Kyoung; Noh, Eui-Kyu; Kim, Jeong Yi; Jo, Jae-Cheol; Choi, Yunsuk; Koh, SuJin; Baek, Jin Ho; Min, Young Joo; Kim, Hawk

    2017-06-05

    Previously, we reported that radotinib, a BCR-ABL1 tyrosine kinase inhibitor, induced cytotoxicity in acute myeloid leukemia (AML) cells. However, the effects of radotinib in the subpopulation of c-KIT-positive AML cells were unclear. We observed that low-concentration radotinib had more potent cytotoxicity in c-KIT-positive cells than c-KIT-negative cells from AML patients. To address this issue, cell lines with high c-KIT expression, HEL92.1.7, and moderate c-KIT expression, H209, were selected. HEL92.1.7 cells were grouped into intermediate and high c-KIT expression populations. The cytotoxicity of radotinib against the HEL92.1.7 cell population with intermediate c-KIT expression was not different from that of the population with high c-KIT expression. When H209 cells were grouped into c-KIT expression-negative and c-KIT expression-positive populations, radotinib induced cytotoxicity in the c-KIT-positive population, but not the c-KIT-negative population. Thus, radotinib induces cytotoxicity in c-KIT-positive cells, regardless of the c-KIT expression intensity. Therefore, radotinib induces significant cytotoxicity in c-KIT-positive AML cells, suggesting that radotinib is a potential target agent for the treatment of c-KIT-positive malignancies including AML. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. LEM-CF Premixed Tool Kit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2015-01-19

    The purpose of LEM-CF Premixed Tool Kit is to process premixed flame simulation data from the LEM-CF solver (https://fileshare.craft-tech.com/clusters/view/lem-cf) into a large-eddy simulation (LES) subgrid model database. These databases may be used with a user-defined-function (UDF) that is included in the Tool Kit. The subgrid model UDF may be used with the ANSYS FLUENT flow solver or other commercial flow solvers.

  3. Differential Use of Elementary Science Kits

    ERIC Educational Resources Information Center

    Jones, Gail; Robertson, Laura; Gardner, Grant E.; Dotger, Sharon; Blanchard, Margaret R.

    2012-01-01

    The use of kits in elementary science classes is a growing trend in some countries. Kits provide materials and inquiry lessons in a ready-to-teach format for teachers to use in their science instruction. This study examined elementary teachers' instructional strategies, classroom practices, and assessment types in relation to the frequency of…

  4. Production of monoclonal antibody and application in indirect competitive ELISA for detecting okadaic acid and dinophytoxin-1 in seafood.

    PubMed

    Lu, Shi-Ying; Zhou, Yu; Li, Yan-Song; Lin, Chao; Meng, Xian-Mei; Yan, Dong-Ming; Li, Zhao-Hui; Yu, Shi-Yu; Liu, Zeng-Shan; Ren, Hong-Lin

    2011-08-01

    Okadaic acid (OA) and analogues of dinophysistoxin (DTX) are key diarrheic shellfish poisoning (DSP) toxins, which possibly arouse DSP symptoms by consuming the contaminated shellfish. Because of the stable toxicity in high temperature and the long-term carcinogenicity, the outbreaks of DSP related to consumption of bivalve mollusks contaminated by DSP toxins pose a hazard to public health. Therefore, it is worth developing a fast and reliable analytical method for the detection of OA and analogues in shellfish. In this paper, an indirect competitive enzyme-linked immunosorbent assay (ELISA) (icELISA) for detecting OA and DTX-1 in seafood was developed based on monoclonal antibody (McAb). The OA was conjugated to human immunoglobulin G (IgG) and bovine serum albumin (BSA) by the active ester method as the immune antigen and the detective antigen. The spleen cells from BALB/c mice immunized with OA-IgG were fused with SP2/0 myeloma cells. A hybridoma cell line, which secreted McAb against OA, was selected by "limiting dilution" cloning. An icELISA was developed based on immobilized conjugate (OA-BSA) competing the McAb with the free OA in seafood sample. A hybridoma cell line, which secreted IgG1 subclass monoclonal antibody (McAb) against OA, was selected. The IC(50) of the McAb for OA and dinophytoxin-1 (DTX-1) were 4.40 and 3.89 ng/mL, respectively. Based on the McAb, an indirect competitive ELISA for detection of OA and DTX-1 in seafood was developed. The regression equation was y = 54.713x - 25.879 with a coefficient correlation of R (2) = 0.9729. The linear range and the limit of detection were 0.4-12.5 and 0.45 ng/mL, respectively. The average recovery of OA and DTX-1 spiked shellfish was 82.29% with the coefficient of variation of 7.67%. The developed icELISA is a fast, sensitive, and convenient assay for detecting of total amount of OA and DTX-1 in seafood.

  5. An improved, rapid competitive ELISA using a novel conserved 3B epitope for the detection of serum antibodies to foot-and-mouth disease virus.

    PubMed

    Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth

    2018-06-01

    The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.

  6. Developing Save Your Food Kit (Sayofu Kit) to Support Inquiry, Improve Student Learning Outcomes at SMP Plus Hidayatul Mubtadiin and Public Awareness on Food Additives

    NASA Astrophysics Data System (ADS)

    Astutik, J.

    2017-02-01

    Food additives are materials that can not be separated from the lives of students and the community. Based on the preliminary questionnaire, it indicates the lack of kit supporting material additives in some schools and communities. The research objectives of this development are (1) to develop Kit experiment (SAYOFU KIT) and supplementary books to improve student learning outcomes in the classroom and public awareness on food additives (2) to describe the feasibility and potential effectiveness of SAYOFU KIT developed (3) to analyze the practice of SAYOFU KIT and benefits for students and the community. This development study uses 4-D models Thiagarajan, et al (1974). Through some stages, they are: defining, designing, developing and disseminating which involes the students and community. The developed SAYOFU KIT includes additives sample kit, borax test kit, curcumin test kit, formaldehyde test kit, modification heater to the identification of dyes and dye test paper. The study is conducted at SMP Plus Hidayatul Mubtadiin, and TKIT Al Uswah. The products are validated by experts and education practitioners. Qualitative data processing uses descriptive method, whereas quantitative data by using the N-gain. The average yield of expert validation of SAYOFU KIT with supplementary books 76.50% teacher’s book and 76.30% student’s book are eligible. The average yield of 96.81% validation of educational practitioners criteria, piloting a small group of 83.15%, and 82.89% field trials are very decent. The average yield on the student questionnaire responses SAYOFU kit and supplementary book is 87.6% with the criteria very well worth it. N-Gain 0:56 cognitive achievement with the criteria enough. The results of the public poll showed 95% feel the benefits SAYOFU kits for testing food. Based from description indicates that SAYOFU Kit developed feasible, practical, useful to support inquiry learning and improve student learning outcomes as well as public awareness of

  7. Honors for the Virtual Frog Dissection Kit

    Science.gov Websites

    Honors for the Virtual Frog Dissection Kit Study Web The dissection kit received a StudyWeb award Frog Project | Virtual Frog Page last modified: 01/23/05 Contacts: Bill Johnston, David Robertson

  8. Indirect ELISA (iELISA) for routine detection of antibodies against Minute Virus of Mice (MVM) in mice colonies.

    PubMed

    Laborde, Juan M; Sguazza, Guillermo H; Fuentealba, Nadia A; Corva, Santiago G; Carbone, Cecilia; Galosi, Cecilia M

    In this study we developed an indirect ELISA to detect antibodies against Minute Virus of Mice (MVM) using an antigen produced from BHK-21 cells infected with a prototype strain of the virus. The optimal antigen concentration and serum dilutions were established. In order to analyze variability in the laboratory, reproducibility and repeatability within and between plates were determined. Then, a panel of 460 sera from conventional facilities and previously classified as positive or negative by the indirect fluorescent antibody assay was analyzed. The cutoff value was determined by a receiver operating characteristic (ROC) curve. The results of the indirect ELISA were compared with those of the indirect fluorescent antibody assay. The ELISA assay showed 100% sensitivity and 99% specificity. ELISA is a useful tool to be developed in standard virology laboratories and can be used for screening animals faster than the traditional indirect fluorescent antibody assay. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  9. c-Kit modifies the inflammatory status of smooth muscle cells.

    PubMed

    Song, Lei; Martinez, Laisel; Zigmond, Zachary M; Hernandez, Diana R; Lassance-Soares, Roberta M; Selman, Guillermo; Vazquez-Padron, Roberto I

    2017-01-01

    c-Kit is a receptor tyrosine kinase present in multiple cell types, including vascular smooth muscle cells (SMC). However, little is known about how c-Kit influences SMC biology and vascular pathogenesis. High-throughput microarray assays and in silico pathway analysis were used to identify differentially expressed genes between primary c-Kit deficient (Kit W/W-v ) and control (Kit +/+ ) SMC. Quantitative real-time RT-PCR and functional assays further confirmed the differences in gene expression and pro-inflammatory pathway regulation between both SMC populations. The microarray analysis revealed elevated NF-κB gene expression secondary to the loss of c-Kit that affects both the canonical and alternative NF-κB pathways. Upon stimulation with an oxidized phospholipid as pro-inflammatory agent, c-Kit deficient SMC displayed enhanced NF-κB transcriptional activity, higher phosphorylated/total p65 ratio, and increased protein expression of NF-κB regulated pro-inflammatory mediators with respect to cells from control mice. The pro-inflammatory phenotype of mutant cells was ameliorated after restoring c-Kit activity using lentiviral transduction. Functional assays further demonstrated that c-Kit suppresses NF-κB activity in SMC in a TGFβ-activated kinase 1 (TAK1) and Nemo-like kinase (NLK) dependent manner. Our study suggests a novel mechanism by which c-Kit suppresses NF-κB regulated pathways in SMC to prevent their pro-inflammatory transformation.

  10. A Simple ELISA Exercise for Undergraduate Biology.

    ERIC Educational Resources Information Center

    Baker, William P.; Moore, Cathy R.

    Understanding of immunological techniques such as the Enzyme Linked Immuno Sorbent Assay (ELISA) is an important part of instructional units in human health, developmental biology, microbiology, and biotechnology. This paper describes a simple ELISA exercise for undergraduate biology that effectively simulates the technique using a paper model.…

  11. Epidemiology of bovine brucellosis in Costa Rica: Lessons learned from failures in the control of the disease

    PubMed Central

    Hernández-Mora, Gabriela; Ruiz-Villalobos, Nazareth; Bonilla-Montoya, Roberto; Romero-Zúniga, Juan-José; Jiménez-Arias, Julio; González-Barrientos, Rocío; Barquero-Calvo, Elías; Chacón-Díaz, Carlos; Rojas, Norman; Chaves-Olarte, Esteban; Guzmán-Verri, Caterina

    2017-01-01

    Brucellosis, caused by Brucella abortus is a major disease of cattle and a zoonosis. In order to estimate the bovine brucellosis prevalence in Costa Rica (CR), a total 765 herds (13078 bovines) from six regions of CR were randomly sampled during 2012–2013. A non-random sample of 7907 herds (532199 bovines) of the six regions, arriving for diagnoses during 2014–2016 to the Costa Rican Animal Health Service was also studied. The prevalence estimated by Rose Bengal test (RBT) ranged from 10.5%-11.4%; alternatively, the prevalence estimated by testing the RBT positives in iELISA, ranged from 4.1%-6.0%, respectively. However, cattle in CR are not vaccinated with B. abortus S19 but with RB51 (vaccination coverage close to 11%), and under these conditions the RBT displays 99% specificity and 99% sensitivity. Therefore, the RBT herd depicted in the random analysis stands as a feasible assessment and then, the recommended value in case of planning an eradication program in CR. Studies of three decades reveled that bovine brucellosis prevalence has increased in CR. B. abortus was identified by biochemical and molecular studies as the etiological agent of bovine brucellosis. Multiple locus variable-number tandem repeat analysis-16 revealed four B. abortus clusters. Cluster one and three are intertwined with isolates from other countries, while clusters two and four have only representatives from CR. Cluster one is widely distributed in all regions of the country and may be the primary B. abortus source. The other clusters seem to be restricted to specific areas in CR. The implications of our findings, in relation to the control of the disease in CR, are critically discussed. PMID:28797045

  12. DEVELOPMENT OF AN IDENTIFICATION KIT FOR SPILLED HAZARDOUS MATERIALS

    EPA Science Inventory

    The Chemical Systems Laboratory (CSL) has developed a field kit to identify spilled hazardous materials in inland waters and on the ground. The Hazardous Materials Spills Identification Kit is a two-component kit consisting of an inverter/shortwave UV lamp unit for photochemical ...

  13. The FLEXTRA kit: a model for instructor support materials.

    PubMed

    Battles, J B; Sheridan, M M

    1989-01-01

    The FLEXTRA Kit is a model for the development of resource materials to support instructor-delivered continuing education. Each FLEXTRA Kit consists of camera-ready copy of handout materials; presentation slides, overheads, videotapes, etc.; evaluation instruments; and an instructor's guide. The FLEXTRA Kit is packaged in such a way that it can be easily shipped and stored. Desktop publishing makes the production of FLEXTRA Kits a cost-effective means of providing support to repeated and locally variable training events.

  14. Specificity of Toxocara ELISA in tropical populations.

    PubMed

    Lynch, N R; Wilkes, L K; Hodgen, A N; Turner, K J

    1988-05-01

    The diagnosis of human infection by Toxocara canis relies heavily upon serological tests, the specificity of which can be inadequate in regions of endemic helminthiasis. When different population groups of tropical Venezuela were evaluated using ELISA based upon Toxocara excretory-secretory antigen (TcESA), solid-phase adsorption of the sera with extracts of a wide variety of non-homologous parasites revealed the existence of significant cross-reactivity. This was effectively and conveniently overcome when the test sera were incubated in the presence of the soluble parasite extracts in a competitive inhibition ELISA. The mean reduction of ELISA values caused by pre-adsorption of the sera tested was 32.2%, and that caused by competitive inhibition was 42.3%, the effects of these two procedures being strongly correlated (r = 0.83). The magnitude of the reduction was inversely proportional to the actual ELISA value (r = -0.55), and ranged from a mean of 68.0% in sera from apparently healthy individuals of medium-high socio-economic level, down to 28.1% in heavily parasitized Amazon indians. Ascaris showed the greatest degree of cross-reactivity in these tests, although under conditions of competitive inhibition even sera with high levels of antibody against this parasite could be negative in Toxocara ELISA. Western blotting revealed a major 81,400 D component that was shared between Ascaris and TcESA. Our results indicate that the competitive inhibition of cross-reactivity by soluble non-homologous parasite extracts provides a convenient and economical means of increasing the specificity of ELISA for the determination of the seroprevalence of toxocariasis in tropical populations.

  15. Comparison of presumptive blood test kits including hexagon OBTI.

    PubMed

    Johnston, Emma; Ames, Carole E; Dagnall, Kathryn E; Foster, John; Daniel, Barbara E

    2008-05-01

    Four presumptive blood tests, Hexagon OBTI, Hemastix(R), Leucomalachite green (LMG), and Kastle-Meyer (KM) were compared for their sensitivity in the identification of dried bloodstains. Stains of varying blood dilutions were subjected to each presumptive test and the results compared. The Hexagon OBTI buffer volume was also reduced to ascertain whether this increased the sensitivity of the kit. The study found that Hemastix(R) was the most sensitive test for trace blood detection. Only with the reduced buffer volume was the Hexagon OBTI kit as sensitive as the LMG and KM tests. However, the Hexagon OBTI kit has the advantage of being a primate specific blood detection kit. This study also investigated whether the OBTI buffer within the kit could be utilized for DNA profiling after presumptive testing. The results show that DNA profiles can be obtained from the Hexagon OBTI kit buffer directly.

  16. Familial associations with paratuberculosis ELISA results in Texas Longhorn cattle.

    PubMed

    Osterstock, Jason B; Fosgate, Geoffrey T; Cohen, Noah D; Derr, James N; Manning, Elizabeth J B; Collins, Michael T; Roussel, Allen J

    2008-05-25

    The objective of this cross-sectional study was to estimate familial associations with paratuberculosis ELISA status in beef cattle. Texas Longhorn cattle (n=715) greater than 2years of age were sampled for paratuberculosis testing using ELISA and fecal culture. Diagnostic test results were indicative of substantial numbers of false-positive serological reactions consistent with environmental exposure to non-MAP Mycobacterium spp. Associations between ancestors and paratuberculosis ELISA status of offspring were assessed using conditional logistic regression. The association between ELISA status of the dam and her offspring was assessed using linear mixed-effect models. Significant associations were identified between some ancestors and offspring ELISA status. The odds of being classified as "suspect" or greater based on ELISA results were 4.6 times greater for offspring of dams with similarly increased S:P ratios. A significant positive linear association was also observed between dam and offspring log-transformed S:P ratios. Results indicate that there is familial aggregation of paratuberculosis ELISA results in beef cattle and suggest that genetic selection based on paratuberculosis ELISA status may decrease seroprevalence. However, genetic selection may have minimal effect on paratuberculosis control in herds with exposure to non-MAP Mycobacterium spp.

  17. Building Use Policies. SPEC Kit 144.

    ERIC Educational Resources Information Center

    Coyle, Patrick

    This Systems and Procedures Exchange Center (SPEC) flyer/kit addresses some of the needs of Association of Research Libraries (ARL) members regarding library building use and the aesthetics and well-being of the materials and people in the building. The kit draws upon documents gathered as part of a 1986 Quick-SPEC survey that dealt with food and…

  18. Germline mutations of KIT in gastrointestinal stromal tumor (GIST) and mastocytosis.

    PubMed

    Ke, Hengning; Kazi, Julhash U; Zhao, Hui; Sun, Jianmin

    2016-01-01

    Somatic mutations of KIT are frequently found in mastocytosis and gastrointestinal stromal tumor (GIST), while germline mutations of KIT are rare, and only found in few cases of familial GIST and mastocytosis. Although ligand-independent activation is the common feature of KIT mutations, the phenotypes mediated by various germline KIT mutations are different. Germline KIT mutations affect different tissues such as interstitial cells of Cajal (ICC), mast cells or melanocytes, and thereby lead to GIST, mastocytosis, or abnormal pigmentation. In this review, we summarize germline KIT mutations in familial mastocytosis and GIST and discuss the possible cellular context dependent transforming activity of KIT mutations.

  19. Loss of c-KIT expression in thyroid cancer cells.

    PubMed

    Franceschi, Sara; Lessi, Francesca; Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria

    2017-01-01

    Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression.

  20. Loss of c-KIT expression in thyroid cancer cells

    PubMed Central

    Panebianco, Federica; Tantillo, Elena; La Ferla, Marco; Menicagli, Michele; Aretini, Paolo; Apollo, Alessandro; Naccarato, Antonio Giuseppe; Marchetti, Ivo; Mazzanti, Chiara Maria

    2017-01-01

    Papillary thyroid carcinoma is the most frequent histologic type of thyroid tumor. Few studies investigated the role of c-KIT expression in thyroid tumors, suggesting a role for this receptor and its ligand in differentiation and growth control of thyroid epithelium and a receptor loss following malignant transformation. We investigated and correlated c-KIT expression levels and two known markers of thyrocytes differentiation, PAX8 and TTF-1, in malignant and benign cytological thyroid samples. Moreover, we performed functional studies on human papillary thyroid carcinoma cell line to associated c-KIT expression to thyrocytes differentiation and tumor proliferation. c-KIT and PAX8 expression resulted higher in benign samples compared to the malignant ones, and the expression levels of these two genes were significantly correlated to each other. We also observed that c-KIT overexpression led to an increase of PAX8 expression level together with a decrease of proliferation. Furthermore, c-KIT overexpressing cells showed a regression of typical morphological features of malignancy. Taken together these results suggest that c-KIT could be involved in the differentiation of thyroid cells and in tumor progression. PMID:28301608

  1. Statistical modeling of dental unit water bacterial test kit performance.

    PubMed

    Cohen, Mark E; Harte, Jennifer A; Stone, Mark E; O'Connor, Karen H; Coen, Michael L; Cullum, Malford E

    2007-01-01

    While it is important to monitor dental water quality, it is unclear whether in-office test kits provide bacterial counts comparable to the gold standard method (R2A). Studies were conducted on specimens with known bacterial concentrations, and from dental units, to evaluate test kit accuracy across a range of bacterial types and loads. Colony forming units (CFU) were counted for samples from each source, using R2A and two types of test kits, and conformity to Poisson distribution expectations was evaluated. Poisson regression was used to test for effects of source and device, and to estimate rate ratios for kits relative to R2A. For all devices, distributions were Poisson for low CFU/mL when only beige-pigmented bacteria were considered. For higher counts, R2A remained Poisson, but kits exhibited over-dispersion. Both kits undercounted relative to R2A, but the degree of undercounting was reasonably stable. Kits did not grow pink-pigmented bacteria from dental-unit water identified as Methylobacterium rhodesianum. Only one of the test kits provided results with adequate reliability at higher bacterial concentrations. Undercount bias could be estimated for this device and used to adjust test kit results. Insensitivity to methylobacteria spp. is problematic.

  2. Relationship between the levels of antibodies to bovine viral diarrhoea virus in bulk tank milk and the prevalence of cows exposed to the virus.

    PubMed

    Niskanen, R

    1993-10-02

    A positive relationship was found between the prevalence of cows in a herd which were antibody-positive for bovine viral diarrhoea virus (BVDV) and the level of antibodies to the virus in bulk tank milk as determined by an indirect enzyme-linked immunosorbent assay (ELISA). In herds with an ELISA absorbance value of up to 0.20 there were very few or no antibody-positive cows, whereas in herds with an ELISA absorbance value of at least 0.81, 87 to 100 per cent of the lactating cows were antibody-positive to BVDV. An analysis of the level of antibodies to BVDV in milk samples from Sweden and Finland showed that of 123 Swedish herds, 83.7 per cent had detectable antibodies to BVDV in their bulk milk whereas only 3.1 per cent of the 291 Finnish samples were antibody-positive. The incidence of BVDV infection in 105 herds in one area of Sweden was determined by analysing two samples of bulk tank milk taken one year apart. The infection had apparently occurred recently in five of these dairy herds.

  3. c-Kit modifies the inflammatory status of smooth muscle cells

    PubMed Central

    Song, Lei; Martinez, Laisel; Zigmond, Zachary M.; Hernandez, Diana R.; Lassance-Soares, Roberta M.; Selman, Guillermo

    2017-01-01

    Background c-Kit is a receptor tyrosine kinase present in multiple cell types, including vascular smooth muscle cells (SMC). However, little is known about how c-Kit influences SMC biology and vascular pathogenesis. Methods High-throughput microarray assays and in silico pathway analysis were used to identify differentially expressed genes between primary c-Kit deficient (KitW/W–v) and control (Kit+/+) SMC. Quantitative real-time RT-PCR and functional assays further confirmed the differences in gene expression and pro-inflammatory pathway regulation between both SMC populations. Results The microarray analysis revealed elevated NF-κB gene expression secondary to the loss of c-Kit that affects both the canonical and alternative NF-κB pathways. Upon stimulation with an oxidized phospholipid as pro-inflammatory agent, c-Kit deficient SMC displayed enhanced NF-κB transcriptional activity, higher phosphorylated/total p65 ratio, and increased protein expression of NF-κB regulated pro-inflammatory mediators with respect to cells from control mice. The pro-inflammatory phenotype of mutant cells was ameliorated after restoring c-Kit activity using lentiviral transduction. Functional assays further demonstrated that c-Kit suppresses NF-κB activity in SMC in a TGFβ-activated kinase 1 (TAK1) and Nemo-like kinase (NLK) dependent manner. Discussion Our study suggests a novel mechanism by which c-Kit suppresses NF-κB regulated pathways in SMC to prevent their pro-inflammatory transformation. PMID:28626608

  4. c-kit+ Cells Minimally Contribute Cardiomyocytes to the Heart

    PubMed Central

    van Berlo, Jop H.; Kanisicak, Onur; Maillet, Marjorie; Vagnozzi, Ronald J.; Karch, Jason; Lin, Suh-Chin J.; Middleton, Ryan C.; Marbán, Eduardo; Molkentin, Jeffery D.

    2014-01-01

    If and how the heart regenerates after an injury event is highly debated. c-kit-expressing cardiac progenitor cells have been reported as the primary source for generation of new myocardium after injury. Here we generated two genetic approaches in mice to examine if endogenous c-kit+ cells contribute differentiated cardiomyocytes to the heart during development, with aging or after injury in adulthood. A cDNA encoding either Cre recombinase or a tamoxifen inducible MerCreMer chimeric protein was targeted to the Kit locus in mice and then bred with reporter lines to permanently mark cell lineage. Endogenous c-kit+ cells did produce new cardiomyocytes within the heart, although at a percentage of ≈0.03% or less, and if a preponderance towards cellular fusion is considered, the percentage falls below ≈0.008%. In contrast, c-kit+ cells amply generated cardiac endothelial cells. Thus, endogenous c-kit+ cells can generate cardiomyocytes within the heart, although likely at a functionally insignificant level. PMID:24805242

  5. Development of an incurred cornbread model for gluten detection by immunoassays.

    PubMed

    Sharma, Girdhari M; Khuda, Sefat E; Pereira, Marion; Slate, Andrew; Jackson, Lauren S; Pardo, Christopher; Williams, Kristina M; Whitaker, Thomas B

    2013-12-11

    Gluten that is present in food as a result of cross-contact or misbranding can cause severe health concerns to wheat-allergic and celiac patients. Immunoassays, such as enzyme-linked immunosorbent assay (ELISA) and lateral flow device (LFD), are commonly used to detect gluten traces in foods. However, the performance of immunoassays can be affected by non-assay-related factors, such as food matrix and processing conditions. Gluten (0-500 ppm) and wheat flour (20-1000 ppm) incurred cornbread was prepared at different incurred levels and baking conditions (204.4 °C for 20, 27, and 34 min) to study the accuracy and precision of gluten measurement by seven immunoassay kits (three LFD and four ELISA kits). The stability and immunoreactivity of gluten proteins, as measured by western blot using three different antibodies, were not adversely affected by the baking conditions. However, the gluten recovery varied depending upon the ELISA kit and the gluten source used to make the incurred cornbread, affecting the accuracy of gluten quantification (BioKits, 9-77%; Morinaga, 91-137%; R-Biopharm, 61-108%; and Romer Labs, 113-190%). Gluten recovery was reduced with increased baking time for most ELISA kits analyzed. Both the sampling and analytical variance increased with an increase in the gluten incurred level. The predicted analytical coefficient of variation associated with all ELISA kits was below 12% for all incurred levels, indicative of good analytical precision.

  6. Protein kinase C-δ-mediated recycling of active KIT in colon cancer.

    PubMed

    Park, Misun; Kim, Won Kyu; Song, Meiying; Park, Minhee; Kim, Hyunki; Nam, Hye Jin; Baek, Sung Hee; Kim, Hoguen

    2013-09-15

    Abnormal signaling through receptor tyrosine kinase (RTK) moieties is important in tumorigenesis and drug targeting of colorectal cancers. Wild-type KIT (WT-KIT), a RTK that is activated upon binding with stem cell factor (SCF), is highly expressed in some colon cancers; however, little is known about the functional role of SCF-dependent KIT activation in colon cancer pathogenesis. We aimed to elucidate the conditions and roles of WT-KIT activation in colon cancer tumorigenesis. Colorectal cancers with KIT expression were characterized by immunoblotting and immunohistochemistry. The biologic alterations after KIT-SCF binding were analyzed with or without protein kinase C (PKC) activation. We found that WT-KIT was expressed in a subset of colon cancer cell lines and was activated by SCF, leading to activation of downstream AKT and extracellular signal-regulated kinase (ERK) signaling pathways. We also showed that KIT expression gradually decreased, after prolonged SCF stimulation, due to lysosomal degradation. Degradation of WT-KIT after SCF binding was significantly rescued when PKC was activated. We also showed the involvement of activated PKC-δ in the recycling of WT-KIT. We further showed that a subset of colorectal cancers exhibit expressions of both WT-KIT and activated PKC-δ and that expression of KIT is correlated with poor patient survival (P = 0.004). Continuous downstream signal activation after KIT-SCF binding is accomplished through PKC-δ-mediated recycling of KIT. This sustained KIT activation may contribute to tumor progression in a subset of colon cancers with KIT expression and might provide the rationale for a therapeutic approach targeting KIT. ©2013 AACR.

  7. KiT: a MATLAB package for kinetochore tracking.

    PubMed

    Armond, Jonathan W; Vladimirou, Elina; McAinsh, Andrew D; Burroughs, Nigel J

    2016-06-15

    During mitosis, chromosomes are attached to the mitotic spindle via large protein complexes called kinetochores. The motion of kinetochores throughout mitosis is intricate and automated quantitative tracking of their motion has already revealed many surprising facets of their behaviour. Here, we present 'KiT' (Kinetochore Tracking)-an easy-to-use, open-source software package for tracking kinetochores from live-cell fluorescent movies. KiT supports 2D, 3D and multi-colour movies, quantification of fluorescence, integrated deconvolution, parallel execution and multiple algorithms for particle localization. KiT is free, open-source software implemented in MATLAB and runs on all MATLAB supported platforms. KiT can be downloaded as a package from http://www.mechanochemistry.org/mcainsh/software.php The source repository is available at https://bitbucket.org/jarmond/kit and under continuing development. Supplementary data are available at Bioinformatics online. jonathan.armond@warwick.ac.uk. © The Author 2016. Published by Oxford University Press.

  8. Low-cost field test kits for arsenic detection in water.

    PubMed

    Das, Joyati; Sarkar, Priyabrata; Panda, Jigisha; Pal, Priyabrata

    2014-01-01

    Arsenic, a common contaminant of groundwater, affects human health adversely. According to the World Health Organization (WHO), the maximum recommended contamination level of arsenic in drinking water is 10 μg/L. The purpose of this research was to develop user-friendly kits for detection of arsenic to measure at least up to 10 μg/L in drinking water, so that a preventive measure could be taken. Two different kits for detection of total arsenic in water are reported here. First, the arsenic in drinking water was converted to arsine gas by a strong reducing agent. The arsine produced was then detected by paper strips via generation of color due to reaction with either mercuric bromide (KIT-1) or silver nitrate (KIT-2). These were previously immobilized on the detector strip. The first one gave a yellow color and the second one grey. Both of these kits could detect arsenic contamination within a range of 10 μg/L-250 μg/L. The detection time for both the kits was only 7 min. The kits exhibited excellent performance compared to other kits available in the market with respect to detection time, ease of operation, cost and could be easily handled by a layman. The field trials with these kits gave very satisfactory results. A study on interference revealed that these kits could be used in the presence of 24 common ions present in the arsenic contaminated water. Though the kits were meant for qualitative assay, the results with unknown concentrations of real samples, when compared with atomic absorption spectrophotometer (AAS) were in good agreement as revealed by the t-test.

  9. [Establishment of A1E3 and B1C4 monoclonal antibody-based ELISA for detecting circulating antigen of Schistosoma japonicum and its preliminary application].

    PubMed

    Cai, Yu-Chun; Chen, Shao-Hong; Tian, Li-Guang; Chu, Yan-Hong; Lu, Yan; Chen, Mu-Xin; Ai, Lin; Zhou, Yang; Chen, Jia-Xu

    2014-02-01

    To establish A1E3 and B1C4 monoclonal antibody-based ELISA for detecting circulating antigen of Schistosoma japonicum and explore its application value in the field. The characteristics of A1E3 and B1C4 monoclonal antibodies were analyzed by SDS-PAGE and Western blotting. The SEA-based ELISA was used to evaluate the titers of A1E3 and B1C4. The orthogonal test was used to determine the best concentration of coating antibody B1C4 and optimal working concentration of A1E3-HRP. Under the optimal conditions, the serum samples of 20 acute schistosomiasis cases, 46 chronic schistosomiasis cases, and 20 control sera were tested to evaluate its detection sensitivity and specificity. Seventy-two antibody positive serum samples from Jiangling County of Hubei Province were detected and compared to a commercially available ELISA kit, to evaluate the detection effects of this method. The results of SDS-PAGE demonstrated that the purified A1E3 and B1C4 contained a clear heavy chain with molecular weight of 88,000 and 52,000 respectively and had the same light chain with molecular weight of 20,000; while Western blotting demonstrated that A1E3 and B1C4 could be recognized by SEA and serum samples of acute schistosomiasis cases. The SEA-based ELISA demonstrated the titers of B1C4 and A1E3 were 1:10(5) and 1:30,000, respectively. The serum samples from all the acute cases and 86.9% of the chronic cases showed a positive reaction. All of the control sera from healthy persons gave a negative response. The positive rates of the double monoclonal antibody ELISA and commercial ELISA for detecting the circulating antigen were 45.8% and 43.1% respectively, and there was no significant difference between the results of the two methods. A1E3 and B1C4 monoclonal antibody-based ELISA is established successfully. It exhibits a high sensitivity and specificity in detecting circulating antigen of Schistosoma japonicum.

  10. Commercial test kits for detection of Lyme borreliosis: a meta-analysis of test accuracy

    PubMed Central

    Cook, Michael J; Puri, Basant K

    2016-01-01

    The clinical diagnosis of Lyme borreliosis can be supported by various test methodologies; test kits are available from many manufacturers. Literature searches were carried out to identify studies that reported characteristics of the test kits. Of 50 searched studies, 18 were included where the tests were commercially available and samples were proven to be positive using serology testing, evidence of an erythema migrans rash, and/or culture. Additional requirements were a test specificity of ≥85% and publication in the last 20 years. The weighted mean sensitivity for all tests and for all samples was 59.5%. Individual study means varied from 30.6% to 86.2%. Sensitivity for each test technology varied from 62.4% for Western blot kits, and 62.3% for enzyme-linked immunosorbent assay tests, to 53.9% for synthetic C6 peptide ELISA tests and 53.7% when the two-tier methodology was used. Test sensitivity increased as dissemination of the pathogen affected different organs; however, the absence of data on the time from infection to serological testing and the lack of standard definitions for “early” and “late” disease prevented analysis of test sensitivity versus time of infection. The lack of standardization of the definitions of disease stage and the possibility of retrospective selection bias prevented clear evaluation of test sensitivity by “stage”. The sensitivity for samples classified as acute disease was 35.4%, with a corresponding sensitivity of 64.5% for samples from patients defined as convalescent. Regression analysis demonstrated an improvement of 4% in test sensitivity over the 20-year study period. The studies did not provide data to indicate the sensitivity of tests used in a clinical setting since the effect of recent use of antibiotics or steroids or other factors affecting antibody response was not factored in. The tests were developed for only specific Borrelia species; sensitivities for other species could not be calculated. PMID

  11. CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals.

    PubMed

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2017-10-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Prevalence of antibodies against Parainfluenza virus type 3, Respiratory syncitial virus and bovine Herpesvirus type 1 in sheep from Northern Prefectures of Japan.

    PubMed

    Giangaspero, Massimo; Savini, Giovanni; Orusa, Riccardo; Osawa, Takeshi; Harasawa, Ryô

    2013-01-01

    Ovine sera collected in the Prefectures of Hokkaido, Aomori and Iwate in the Northern Japan were examined for the presence of antibodies against Respiratory syncytial virus (RSV), bovine Herpesvirus type 1 (infectious bovine rhinotracheitis: IBR) and Parainfluenza virus type 3 (PIV3) using serum neutralisation (SN) and enzyme-linked immunosorbent assay (ELISA) tests. Twenty-three animals (11.73%) out of the 196 tested were sero-positive to PIV3. Sixteen animals (8.69%) out of the 184 tested reacted to RSV. No animals were positive to IBR antigen. Sero-conversions to PIV3 were detected in Hokkaido and Iwate (14.92% and 8.82%, respectively). Antibodies against RSV were detected in Hokkaido (9.23%) and Aomori (14.28%). Although no diagnostic measures were in place, the infections did not appear to be related to any reduction in sheep productivity.

  13. Bovine Respiratory Syncytial Virus and Histophilus somni Interaction at the Alveolar Barrier

    PubMed Central

    Agnes, J. T.; Zekarias, B.; Shao, M.; Anderson, M. L.; Gershwin, L. J.

    2013-01-01

    Our previous studies showed that Histophilus somni and bovine respiratory syncytial virus (BRSV) act synergistically in vivo to cause more severe bovine respiratory disease than either agent alone causes. Since H. somni surface and secreted immunoglobulin binding protein A (IbpA) causes retraction of bovine alveolar type 2 (BAT2) cells and invasion between BAT2 cells in vitro, we investigated mechanisms of BRSV-plus-H. somni infection at the alveolar barrier. BRSV treatment of BAT2 cells prior to treatment with IbpA-rich H. somni concentrated culture supernatant (CCS) resulted in increased BAT2 cell rounding and retraction compared to those with either treatment alone. This mimicked the increased alveolar cell thickening in calves experimentally infected with BRSV followed by H. somni compared to that in calves infected with BRSV or H. somni alone. BRSV-plus-H. somni CCS treatment of BAT2 cells also enhanced paracellular migration. The effect of matrix metalloproteinases (MMPs) was investigated as well because microarray analysis revealed that treatment with BRSV plus H. somni synergistically upregulated BAT2 cell expression of mmp1 and mmp3 compared to that in cells treated with either agent alone. Enzyme-linked immunosorbent assay (ELISA) confirmed that MMP1 and MMP3 protein levels were similarly upregulated. In collagen I and collagen IV (targets for MMP1 and MMP3, respectively) substrate zymography, digestion was increased with supernatants from dually treated BAT2 cells compared with those from singly treated cells. Enhanced breakdown of collagen IV in the basal lamina and of fibrillar collagen I in the adjacent interstitium in the dual infection may facilitate dissemination of H. somni infection. PMID:23649093

  14. Bovine respiratory syncytial virus and Histophilus somni interaction at the alveolar barrier.

    PubMed

    Agnes, J T; Zekarias, B; Shao, M; Anderson, M L; Gershwin, L J; Corbeil, L B

    2013-07-01

    Our previous studies showed that Histophilus somni and bovine respiratory syncytial virus (BRSV) act synergistically in vivo to cause more severe bovine respiratory disease than either agent alone causes. Since H. somni surface and secreted immunoglobulin binding protein A (IbpA) causes retraction of bovine alveolar type 2 (BAT2) cells and invasion between BAT2 cells in vitro, we investigated mechanisms of BRSV-plus-H. somni infection at the alveolar barrier. BRSV treatment of BAT2 cells prior to treatment with IbpA-rich H. somni concentrated culture supernatant (CCS) resulted in increased BAT2 cell rounding and retraction compared to those with either treatment alone. This mimicked the increased alveolar cell thickening in calves experimentally infected with BRSV followed by H. somni compared to that in calves infected with BRSV or H. somni alone. BRSV-plus-H. somni CCS treatment of BAT2 cells also enhanced paracellular migration. The effect of matrix metalloproteinases (MMPs) was investigated as well because microarray analysis revealed that treatment with BRSV plus H. somni synergistically upregulated BAT2 cell expression of mmp1 and mmp3 compared to that in cells treated with either agent alone. Enzyme-linked immunosorbent assay (ELISA) confirmed that MMP1 and MMP3 protein levels were similarly upregulated. In collagen I and collagen IV (targets for MMP1 and MMP3, respectively) substrate zymography, digestion was increased with supernatants from dually treated BAT2 cells compared with those from singly treated cells. Enhanced breakdown of collagen IV in the basal lamina and of fibrillar collagen I in the adjacent interstitium in the dual infection may facilitate dissemination of H. somni infection.

  15. Laboratory Findings Suggesting an Association Between BoHV-4 and Bovine Abortions in Southern Belgium.

    PubMed

    Delooz, L; Czaplicki, G; Houtain, J Y; Dal Pozzo, F; Saegerman, C

    2017-08-01

    Abortions cause heavy economic losses for the bovine sector. The use of a standardized panel of analyses covering a large spectrum of pathogens responsible of abortion in cattle allowed demonstrating the direct involvement of at least one pathogen in 57% of analysed abortions in the southern part of Belgium. This result suggests a margin of improvement in the diagnostic efficacy. In order to evaluate the interest to broaden the list of pathogens included in the panel of analyses, the implication of bovine herpesvirus 4 (BoHV-4) in abortion was assessed by two different studies. In the first study, coupled serology was performed after abortion on 714 dams to identify specific seroconversion against BoHV-4. The overall seroconversion in cows was 19.5%, with a higher frequency in primiparous compared to multiparous females. In addition, the type of breed (beef cattle) and the time period from the fourth quarter 2008 until the last quarter 2009 were significantly related to the seroconversion of cows. The second study investigated the virus ability to infect the foetus. In this study, 368 cases of bovine abortions were specifically tested for BoHV-4, using PCR on foetus tissues and ELISA on dam and foetus sera. The results showed a maternal seroprevalence of 64.7%, a foetal seroprevalence of 0.8% and a PCR prevalence in foetuses of 1.1%, demonstrating the ability of BoHV-4 to infect the foetus. © 2016 Blackwell Verlag GmbH.

  16. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  17. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  18. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  19. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  20. 21 CFR 878.3925 - Plastic surgery kit and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Plastic surgery kit and accessories. 878.3925... (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Prosthetic Devices § 878.3925 Plastic surgery kit and accessories. (a) Identification. A plastic surgery kit and accessories is a device intended to...

  1. Spatial Distribution and Receptor Specificity of Zebrafish Kit System - Evidence for a Kit-Mediated Bi-Directional Communication System in the Preovulatory Ovarian Follicle

    PubMed Central

    Yao, Kai; Ge, Wei

    2013-01-01

    Consisting of Kit ligand and receptor Kit, the Kit system is involved in regulating many ovarian functions such as follicle activation, granulosa cell proliferation, and oocyte growth and maturation. In mammals, Kit ligand is derived from the granulosa cells and Kit receptor is expressed in the oocyte and theca cells. In the zebrafish, the Kit system contains two ligands (Kitlga and Kitlgb) and two receptors (Kita and Kitb). Interestingly, Kitlga and Kitb are localized in the somatic follicle cells, but Kitlgb and Kita are expressed in the oocyte. Using recombinant zebrafish Kitlga and Kitlgb, we demonstrated that Kitlga preferentially activated Kita whereas Kitlgb specifically activated Kitb by Western analysis for receptor phosphorylation. In support of this, Kitlgb triggered a stronger and longer MAPK phosphorylation in follicle cells than Kitlga, whereas Kitlga but not Kitlgb activated MAPK in the denuded oocytes, in agreement with the distribution of Kita and Kitb in the follicle and their specificity for Kitlga and Kitlgb. Further analysis of the interaction between Kit ligands and receptors by homology modeling showed that Kitlga-Kita and Kitlgb-Kitb both have more stable electrostatic interaction than Kitlgb-Kita or Kitlga-Kitb. A functional study of Kit involvement in final oocyte maturation showed that Kitlga and Kitlgb both suppressed the spontaneous maturation significantly; in contrast, Kitlgb but not Kitlga significantly promoted 17α, 20β-dihydroxy-4-pregnen-3-one (DHP) -induced oocyte maturation. Our results provided strong evidence for a Kit-mediated bi-directional communication system in the zebrafish ovarian follicle, which could be part of the complex interplay between the oocyte and the follicle cells in the development of follicles. PMID:23409152

  2. Proactive therapeutic drug monitoring of infliximab: a comparative study of a new point-of-care quantitative test with two established ELISA assays.

    PubMed

    Afonso, J; Lopes, S; Gonçalves, R; Caldeira, P; Lago, P; Tavares de Sousa, H; Ramos, J; Gonçalves, A R; Ministro, P; Rosa, I; Vieira, A I; Dias, C C; Magro, F

    2016-10-01

    Therapeutic drug monitoring is a powerful strategy known to improve the clinical outcomes and to optimise the healthcare resources in the treatment of autoimmune diseases. Currently, most of the methods commercially available for the quantification of infliximab (IFX) are ELISA-based, with a turnaround time of approximately 8 h, and delaying the target dosage adjustment to the following infusion. To validate the first point-of-care IFX quantification device available in the market - the Quantum Blue Infliximab assay (Buhlmann, Schonenbuch, Switzerland) - by comparing it with two well-established methods. The three methods were used to assay the IFX concentration of spiked samples and of the serum of 299 inflammatory bowel diseases (IBD) patients undergoing IFX therapy. The point-of-care assay had an average IFX recovery of 92%, being the most precise among the tested methods. The Intraclass Correlation Coefficients of the point-of-care IFX assay vs. the two ELISA-based established methods were 0.889 and 0.939. Moreover, the accuracy of the point-of-care IFX compared with each of the two reference methods was 77% and 83%, and the kappa statistics revealed a substantial agreement (0.648 and 0.738). The Quantum Blue IFX assay can successfully replace the commonly used ELISA-based IFX quantification kits. This point-of-care IFX assay is able to deliver the results within 15 min makes it ideal for an immediate target concentration adjusted dosing. Moreover, it is a user-friendly desktop device that does not require specific laboratory facilities or highly specialised personnel. © 2016 John Wiley & Sons Ltd.

  3. Measurement of Lp(a) with a two-step monoclonal competitive sandwich ELISA method.

    PubMed

    Morikawa, W; Iki, R; Terano, T; Funatsu, A; Sugiuchi, H; Uji, Y; Okabe, H

    1995-06-01

    To evaluate the results of Lipoprotein (a)[Lp(a)] measurements by a competitive two-step monoclonal enzyme-linked immuno sorbent assay method comparing them with those by a conventional ELISA. Serum having various isoforms of Lp(a) and purified Lp(a) were assayed using the method described here and commercially available kits. The reference range was determined with the use of 324 normal subjects by means of calculation from Lp(a) results of logarithmic transformation. Our method takes advantage of a competitive reaction between fixed antibody and free antibody to Lp(a), having the detection range up to 1000 mg/L with the lowest detection limit of 2 mg/L. The anti-Lp(a) monoclonal antibody employed in the assay system reacts uniformly with all phenotypes of Lp(a) but showing very low cross-reactivity for plasminogen and LDL. Within-run and between-run precisions were excellent, giving CVs of 2.9 and 4.0% with mean values of 145 and 635 mg/L, respectively. In comparison of the results by our method with those by a polyclonal method (Biopool) or a monoclonal antibody method (Terumo), they correlated well; Y (our method) = 0.99 x (polyclonal method, Biopool) - 1.9, r = 0.994 (n = 60), and Y = 0.94 X(monoclonal method, Terumo) -9.8, r = 0.97 (n = 60), respectively. The reference range was 105.9 +/- 25.4 mg/L, the difference between the sexes was not significant. Our method has proven highly accurate and specific. It is applicable with auto analyzer because it does not require such a pre-dilution step as is necessary for Lp(a) determination by conventional ELISA assay. Accordingly, we can conclude that our test method is workable for both clinical laboratories and mass screening.

  4. Determination of Asymmetric and Symmetric Dimethylarginine in Serum from Patients with Chronic Kidney Disease: UPLC-MS/MS versus ELISA.

    PubMed

    Boelaert, Jente; Schepers, Eva; Glorieux, Griet; Eloot, Sunny; Vanholder, Raymond; Lynen, Frédéric

    2016-05-13

    Asymmetric dimethylarginine (ADMA), an endogenous inhibitor of nitric oxide (NO) synthesis, and its structural isomer symmetric dimethylarginine (SDMA) are uremic toxins accumulating in chronic kidney disease (CKD) patients. The objective of this study was to develop and validate a robust UPLC-MS/MS method for the simultaneous determination of ADMA and SDMA in human serum. Chromatographic separation after butyl ester derivatization was achieved on an Acquity UPLC BEH C18 column, followed by tandem mass spectrometric detection. After validation, the applicability of the method was evaluated by the analysis of serum samples from 10 healthy controls and 77 CKD patients on hemodialysis (CKD5HD). Both ADMA (0.84 ± 0.19 µM vs. 0.52 ± 0.07 µM) and SDMA concentrations (2.06 ± 0.82 µM vs. 0.59 ± 0.13 µM) were significantly (p < 0.001) elevated in CKD5HD patients compared to healthy controls. In general, low degrees of protein binding were found for both ADMA and SDMA. In addition, an established commercially available ELISA kit was utilized on the same samples (n = 87) to compare values obtained both with ELISA and UPLC-MS/MS. Regression analysis between these two methods was significant (p < 0.0001) but moderate for both ADMA (R = 0.78) and SDMA (R = 0.72).

  5. A simple, specific high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin in cell culture medium.

    PubMed

    Li, Ye; Cassone, Vincent M

    2015-09-01

    A simple, specific, high-throughput enzyme-linked immunosorbent assay (ELISA) for quantitative determination of melatonin was developed for directly measuring melatonin in cell culture medium with 10% FBS. This assay adopts a commercial monoclonal melatonin antibody and melatonin-HRP conjugate, so it can be applied in multiple labs rapidly with low cost compared with commercial RIA and ELISA kits. In addition, the procedure is much simpler with only four steps: 1) sample/conjugate incubation, 2) plate washing, 3) TMB color reaction and 4) reading of results. The standards of the assay cover a wide working range from 100 pg/mL to 10 ng/mL. The sensitivity was 68 pg/mL in cell culture medium with 10% FBS and 26 pg/mL in PBS with as little as 25 μL sample volume. The recovery of melatonin from cell culture medium was 101.0%. The principal cross-reacting compound was 5-methoxytryptophol (0.1%). The variation coefficients of the assay, within and between runs, ranged between 6.68% and 15.76% in cell culture medium. The mean linearity of a series diluted cell culture medium sample was 105% (CV=5%), ranging between 98% and 111%, y=5.5263x+0.0646, R(2)=0.99. The assay enables small research and teaching labs to reliably measure this important neurohormone. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. C-MORE Science Kits as a Classroom Learning Tool

    ERIC Educational Resources Information Center

    Foley, J. M.; Bruno, B. C.; Tolman, R. T.; Kagami, R. S.; Hsia, M. H.; Mayer, B.; Inazu, J. K.

    2013-01-01

    To support teachers in enhancing ocean literacy, the Center for Microbial Oceanography: Research and Education (C-MORE) has developed a series of portable, hands-on science kits on selected topics in oceanography. This paper provides an overview of kit content, describes how the kits were developed, and evaluates their efficacy as a curriculum…

  7. Multi-analyte validation in heterogeneous solution by ELISA.

    PubMed

    Lakshmipriya, Thangavel; Gopinath, Subash C B; Hashim, Uda; Murugaiyah, Vikneswaran

    2017-12-01

    Enzyme Linked Immunosorbent Assay (ELISA) is a standard assay that has been used widely to validate the presence of analyte in the solution. With the advancement of ELISA, different strategies have shown and became a suitable immunoassay for a wide range of analytes. Herein, we attempted to provide additional evidence with ELISA, to show its suitability for multi-analyte detection. To demonstrate, three clinically relevant targets have been chosen, which include 16kDa protein from Mycobacterium tuberculosis, human blood clotting Factor IXa and a tumour marker Squamous Cell Carcinoma antigen. Indeed, we adapted the routine steps from the conventional ELISA to validate the occurrence of analytes both in homogeneous and heterogeneous solutions. With the homogeneous and heterogeneous solutions, we could attain the sensitivity of 2, 8 and 1nM for the targets 16kDa protein, FIXa and SSC antigen, respectively. Further, the specific multi-analyte validations were evidenced with the similar sensitivities in the presence of human serum. ELISA assay in this study has proven its applicability for the genuine multiple target validation in the heterogeneous solution, can be followed for other target validations. Copyright © 2017 Elsevier B.V. All rights reserved.

  8. Education kits for fiber optics, optoelectronics, and optical communications

    NASA Astrophysics Data System (ADS)

    Hájek, Martin; Švrček, Miroslav

    2007-04-01

    Our company MIKROKOM, s.r.o. is engaged for many years in development of education equipment and kits for fiber optics, optoelectronics and optical communications. We would like to inform competitors of conference about results of this long-time development. Requirements on education kits and equipment in a modern and dynamic area as is optical communications and fiber optics are quite difficult. The education kits should to clearly introduce students to given issue - the most important physical principles and technical approaches, but it should to introduce also to new and modern technologies, which are quickly changing and developing. On the other hand should be these tools and kits reasonable for the schools. In our paper we would like to describe possible ways of development of this education kits and equipment and present our results of long-time work, which covers very wide range. On the one hand we developed equipment and kits for clear demonstration of physical effects using plastic optical fibers POF, next we prepare kits with a glass fibers, which are the most used fibers in practice and after as much as the kits, which covers broad range of passive and active elements of the optical networks and systems and which makes possible to create complex optical transmission connection. This kind of systems with using corresponding tools and equipment introduce the students to properties, manipulation, measurement and usage of optical fibers, traces and many active and passive components. Furthermore, with using different sorts of optical sources, photodetectors, fiber optics couplers etc., students can get acquainted with all optoelectronics transmission system, which uses different sorts of signals. Special part will be devoted also to effort mentioned before - to implement modern technologies such as e.g. Wavelength Division Multiplex (WDM) into the education kits. Our presentation will inform auditors about development of mentioned education kits and

  9. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Anesthesia conduction kit. 868.5140 Section 868.5140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a...

  10. 21 CFR 868.5140 - Anesthesia conduction kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Anesthesia conduction kit. 868.5140 Section 868.5140 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5140 Anesthesia conduction kit. (a...

  11. Bovine TLR2 and TLR4 mediate Cryptosporidium parvum recognition in bovine intestinal epithelial cells.

    PubMed

    Yang, Zhengtao; Fu, Yunhe; Gong, Pengtao; Zheng, Jingtong; Liu, Li; Yu, Yuqiang; Li, Jianhua; Li, He; Yang, Ju; Zhang, Xichen

    2015-08-01

    Cryptosporidium parvum (C. parvum) is an intestinal parasite that causes diarrhea in neonatal calves. It results in significant morbidity of neonatal calves and economic losses for producers worldwide. Innate resistance against C. parvum is thought to depend on engagement of pattern recognition receptors. However, the role of innate responses to C. parvum has not been elucidated in bovine. The aim of this study was to evaluate the role of TLRs in host-cell responses during C. parvum infection of cultured bovine intestinal epithelial cells. The expressions of TLRs in bovine intestinal epithelial cells were detected by qRT-PCR. To determine which, if any, TLRs may play a role in the response of bovine intestinal epithelial cells to C. parvum, the cells were stimulated with C. parvum and the expression of TLRs were tested by qRT-PCR. The expression of NF-κB was detected by western blotting. Further analyses were carried out in bovine TLRs transfected HEK293 cells and by TLRs-DN transfected bovine intestinal epithelial cells. The results showed that bovine intestinal epithelial cells expressed all known TLRs. The expression of TLR2 and TLR4 were up-regulated when bovine intestinal epithelial cells were treated with C. parvum. Meanwhile, C. parvum induced IL-8 production in TLR2 or TLR4/MD-2 transfected HEK293 cells. Moreover, C. parvum induced NF-κB activation and cytokine expression in bovine intestinal epithelial cells. The induction of NF-κB activation and cytokine expression by C. parvum were reduced in TLR2-DN and TLR4-DN transfected cells. The results showed that bovine intestinal epithelial cells expressed all known TLRs, and bovine intestinal epithelial cells recognized and responded to C. parvum via TLR2 and TLR4. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. Association of KIT exon 9 mutations with nongastric primary site and aggressive behavior: KIT mutation analysis and clinical correlates of 120 gastrointestinal stromal tumors.

    PubMed

    Antonescu, Cristina R; Sommer, Gunhild; Sarran, Lisa; Tschernyavsky, Sylvia J; Riedel, Elyn; Woodruff, James M; Robson, Mark; Maki, Robert; Brennan, Murray F; Ladanyi, Marc; DeMatteo, Ronald P; Besmer, Peter

    2003-08-15

    Activating mutations of the KIT juxtamembrane region are the most common genetic events in gastrointestinal stromal tumors (GISTs) and have been noted as independent prognostic factors. The impact of KIT mutation in other regions, such as the extracellular or kinase domains, is not well-defined and fewer than 30 cases have been published to date. One hundred twenty GISTs, confirmed by KIT immunoreactivity, were evaluated for the presence of KIT exon 9, 11, 13, and 17 mutations. The relation between the presence/type of KIT mutation and clinicopathological factors was analyzed using Fisher's exact test and log-rank test. Forty-four % of the tumors were located in the stomach, 47% in the small bowel, 6% in the rectum, and 3% in the retroperitoneum. Overall, KIT mutations were detected in 78% of patients as follows: 67% in exon 11, 11% in exon 9, and none in exon 13 or 17. The types of KIT exon 11 mutations were heterogeneous and clustered in the classic "hot spot" at the 5' end of exon 11. Seven % of cases showed internal tandem duplications (ITD) at the 3' end of exon 11, in a region that we designate as a second hot spot for KIT mutations. Interestingly, these cases were associated with: female predominance, stomach location, occurrence in older patients, and favorable outcome. There were significant associations between exon 9 mutations and large tumor size (P < 0.001) and extragastric location (P = 0.02). Ten of these 13 patients with more than 1-year follow-up have developed recurrent disease. Most KIT-expressing GISTs show KIT mutations that are preferentially located within the classic hot spot of exon 11. In addition, we found an association between a second hot spot at the 3'end of exon 11, characterized by ITDs, and a subgroup of clinically indolent gastric GISTs in older females. KIT exon 9 mutations seem to define a distinct subset of GISTs, located predominantly in the small bowel and associated with an unfavorable clinical course.

  13. Home Pregnancy Test Kits: How Readable Are the Instructions?

    ERIC Educational Resources Information Center

    Holcomb, Carol Ann

    At the conclusion of their study on home pregnancy test kits, Valinas and Perlman (1982) suggested that the instructions accompanying the kits be revised to make them easier to read. A study was undertaken to determine the readability of the printed instructions accompanying five home pregnancy test kits (Daisy II, Answer, Acu-Test, Predictor, and…

  14. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  15. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  16. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  17. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  18. 21 CFR 880.5760 - Chemical cold pack snakebite kit.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Chemical cold pack snakebite kit. 880.5760 Section... Therapeutic Devices § 880.5760 Chemical cold pack snakebite kit. (a) Identification. A chemical cold pack snakebit kit is a device consisting of a chemical cold pack and tourniquet used for first-aid treatment of...

  19. The Dot Blot ELISA.

    ERIC Educational Resources Information Center

    Gerbig, Donald G., Jr.; Fenk, Christopher J.; Goodhart, Amy S.

    2000-01-01

    Uses two laboratory techniques, Enzyme Linked Immunosorbent Assay (ELISA) and Western Blot, to demonstrate antibody-antigen binding concepts. Includes a list of required materials and directions for the procedure, and makes suggestions for classroom applications. (Contains 13 references.) (YDS)

  20. An rK28-Based Immunoenzymatic Assay for the Diagnosis of Canine Visceral Leishmaniasis in Latin America

    PubMed Central

    Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.

    2016-01-01

    Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270

  1. Working with Self-Injurious Adolescents Using the Safe Kit

    ERIC Educational Resources Information Center

    Moyer, Michael

    2008-01-01

    This article offers a guide for using the Safe Kit when working with clients who self-injure. The Safe Kit can be used as a supplement to more traditional approaches to counseling and offers clients alternatives to self-injury when they need alternatives the most. The Safe Kit works under the assumption that individuals differ in the meaning they…

  2. Evaluation of Two Enzyme-Linked Immunosorbent Assay Kits for Chikungunya Virus IgM Using Samples from Deceased Organ and Tissue Donors.

    PubMed

    Prince, Harry E; Altrich, Michelle L; Nowicki, Marek J

    2016-10-01

    The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  3. Evaluation of Two Enzyme-Linked Immunosorbent Assay Kits for Chikungunya Virus IgM Using Samples from Deceased Organ and Tissue Donors

    PubMed Central

    Altrich, Michelle L.; Nowicki, Marek J.

    2016-01-01

    The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. PMID:27535838

  4. Identification of mutations in the coding sequence of the proto-oncogene c-kit in a human mast cell leukemia cell line causing ligand-independent activation of c-kit product.

    PubMed Central

    Furitsu, T; Tsujimura, T; Tono, T; Ikeda, H; Kitayama, H; Koshimizu, U; Sugahara, H; Butterfield, J H; Ashman, L K; Kanayama, Y

    1993-01-01

    The c-kit proto-oncogene encodes a receptor tyrosine kinase. Binding of c-kit ligand, stem cell factor (SCF) to c-kit receptor (c-kitR) is known to activate c-kitR tyrosine kinase, thereby leading to autophosphorylation of c-kitR on tyrosine and to association of c-kitR with substrates such as phosphatidylinositol 3-kinase (PI3K). In a human mast cell leukemia cell line HMC-1, c-kitR was found to be constitutively phosphorylated on tyrosine, activated, and associated with PI3K without the addition of SCF. The expression of SCF mRNA transcript in HMC-1 cells was not detectable by means of PCR after reverse transcription (RT-PCR) analysis, suggesting that the constitutive activation of c-kitR was ligand independent. Sequencing of whole coding region of c-kit cDNA revealed that c-kit genes of HMC-1 cells were composed of a normal, wild-type allele and a mutant allele with two point mutations resulting in intracellular amino acid substitutions of Gly-560 for Val and Val-816 for Asp. Amino acid sequences in the regions of the two mutations are completely conserved in all of mouse, rat, and human c-kit. In order to determine the causal role of these mutations in the constitutive activation, murine c-kit mutants encoding Gly-559 and/or Val-814, corresponding to human Gly-560 and/or Val-816, were constructed by site-directed mutagenesis and expressed in a human embryonic kidney cell line, 293T cells. In the transfected cells, both c-kitR (Gly-559, Val-814) and c-kitR (Val-814) were abundantly phosphorylated on tyrosine and activated in immune complex kinase reaction in the absence of SCF, whereas tyrosine phosphorylation and activation of c-kitR (Gly-559) or wild-type c-kitR was modest or little, respectively. These results suggest that conversion of Asp-816 to Val in human c-kitR may be an activating mutation and responsible for the constitutive activation of c-kitR in HMC-1 cells. Images PMID:7691885

  5. Prevalence of bovine brucellosis in slaughtered cattle and barriers to better protection of abattoir workers in Ibadan, South-Western Nigeria.

    PubMed

    Ayoola, Modupe Comfort; Akinseye, Victor Oluwatoyin; Cadmus, Eniola; Awosanya, Emmanuel; Popoola, Olufemi Akinyele; Akinyemi, Oluwaseun Oladapo; Perrett, Lorraine; Taylor, Andrew; Stack, Judy; Moriyon, Ignacio; Cadmus, Simeon Idowu

    2017-01-01

    Brucellosis is a neglected zoonosis of public health importance. This study was conducted to determine the prevalence and risk factors of brucellosis among slaughtered cattle as well as challenges to the protection of abattoir workers in Nigeria. A slaughterhouse study was conducted in a major abattoir in Ibadan from March to August, 2013. To diagnose brucellosis, serum samples from 1,241 slaughtered cattle were tested using Rose-Bengal test (RBT) and competitive enzyme-linked immunosorbent assay (cELISA); again, 57 milk samples were tested with milk ring test (MRT) and indirect ELISA (iELISA). Furthermore, a survey on the usage of personal protective equipment (PPE) and challenges to its use by abattoir workers was done. Data were analysed using Stata 12. Seroprevalence by RBT was 7.8%; 77.3% (75/97) of these were corroborated by cELISA. Prevalence in milk samples by MRT and indirect ELISA were 33.3% and 3.5%, respectively. Sex (OR: 2.5; 95%CI:1.3-4.5) was the factor significantly associated with Brucella seropositivity. None of the abattoir workers used standard protective overalls; while, 99.6% of the meat handlers and 84.1% of the butchers worked barefoot. Most of the workers (75.7%) wore no protective gloves. The respondents agreed that provision of free PPE and sanctions against non-users would encourage its use. Our findings indicate moderate prevalence (7.8%) of bovine brucellosis with sex of cattle being a risk factor. A notable barrier to better protection of abattoir workers against brucellosis is perceived inconvenience arising from use of gloves. Therefore, preventive and control measures against brucellosis must include education and use of PPE among abattoir workers.

  6. High prevalence of bovine cysticercosis found during evaluation of different post-mortem detection techniques in Belgian slaughterhouses.

    PubMed

    Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Eichenberger, Ramon Marc; Deplazes, Peter; Gabriël, Sarah

    2017-09-15

    Bovine cysticercosis (BCC), caused by the helminth Taenia saginata, is currently diagnosed solely by official meat inspection (MI) based on macroscopic detection of viable cysticerci or typical lesions of degenerated larvae. MI has a known low sensitivity (<16%), leading to a large proportion of infected cattle carcasses entering the human food chain and posing a risk to public health. Prevalence in Belgium based on MI results is estimated at around 0.22%. Due to the low sensitivity of MI, alternative techniques to detect BCC should be considered. This study evaluates MI, MI with additional incisions in the heart, specific antibody detection against excretory/secretory (E/S) in the Ab-ELISA and circulating antigens in the B158/B60 Ag-ELISA on 715 (101 MI-positive and 614 MI-negative) samples collected from carcasses at slaughterhouses in Belgium. Full dissection of the predilection sites was considered the reference test. During the study, mostly carcasses with (very) light infections were detected containing predominantly degenerated or calcified cysticerci and only few viable cysticerci. Dissection of the predilection sites detected 144 (23%) additional infections in the 614 MI-negative carcasses. When sequentially performing first the dissection of the predilection sites, followed by the Ag-ELISA and the Ab-ELISA, an additional 36% of MI-negative carcasses were found positive for BCC, resulting in a prevalence very much higher than the above mentioned 0.22%. The B158/B60 Ag-ELISA showed a sensitivity of 40% for the detection of carcasses containing viable cysticerci and a specificity of 100%, and detected 70 positive carcasses of which only 14 had been identified as positive during MI. If Ag-ELISA were implemented as a detection technique for BCC in the slaughterhouses, many infected carcasses would still not be detected due to the sensitivity of 40%. But as sensitivity increases with increasing number of cysticerci in the carcass, the infected carcasses passing

  7. No GIST-type c-kit gain of function mutations in neuroblastic tumours

    PubMed Central

    Korja, M; Finne, J; Salmi, T T; Haapasalo, H; Tanner, M; Isola, J

    2005-01-01

    Aims: Neuroblastic tumours (NTs) have been shown to respond to imatinib treatment in vivo and in vitro, possibly via inactivating the c-kit receptor. The purpose of this study was to identify gastrointestinal stromal tumour (GIST)-type c-kit gene associated mutations in exons 9, 11, 13, and 17 in NTs to recognise a subset of tumours that would probably respond to imatinib treatment. Methods: Expression of the c-kit protein was detected immunohistochemically in a total of 37 archival paraffin wax embedded NTs using polyclonal rabbit antihuman c-kit antibody. After immunohistochemistry, c-kit gene associated chromosomal mutations in all cases of NT were detected with denaturing high performance liquid chromatography (HPLC). Results: Denaturing HLPC analysis did not reveal GIST-type mutations in four immunohistochemically detected c-kit positive or in 33 c-kit negative NTs. Conclusions: c-kit receptor expression and GIST-type c-kit gene mutations are rare events in NTs. Oncogenic activation of c-kit in NTs presumably differs from that of GISTs, which may influence their responsiveness to imatinib treatment. Whether c-kit has an essential role in the pathogenesis of NTs remains to be investigated. PMID:15976348

  8. 21 CFR 872.3600 - Partially fabricated denture kit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with the oral tissues. After the denture base is constructed, the connected preformed teeth are...: Evaluation and Testing,’ ” and (2) “OTC Denture Reliners, Repair Kits, and Partially Fabricated Denture Kits...

  9. Proteoglycan 4 (PRG4) synthesis and immunolocalization in bovine meniscus.

    PubMed

    Schumacher, Barbara L; Schmidt, Tannin A; Voegtline, Michael S; Chen, Albert C; Sah, Robert L

    2005-05-01

    Proteoglycan 4 (PRG4) is synthesized and secreted into the synovial fluid by articular chondrocytes and synovial cells, lining the cavity of joints. A thin layer of PRG4 is also present at the articular surface, where it appears to be involved in boundary lubrication. This study investigated if PRG4 is also synthesized and secreted by the cells within meniscus, and if PRG4 is also present in, and at the surface of, meniscus. PRG4 was visualized in sections of bovine calf menisci by immunohistochemistry. PRG4 was detected in two regions: (1) at the femoral and tibial surfaces of the meniscus, and within cells below these surfaces; and (2) within and near cells along the radial tie fibers and circumferential fibers. From meniscus tissue harvested from these surfaces, PRG4 was extracted with 4M GuHCl and quantified by ELISA. There was 0.20 +/- 0.01 and 0.25 +/- 0.04 microg PRG4/cm(2) area of lateral and medial meniscus surface, respectively. ELISA analysis of spent medium from other samples of meniscus surface tissue incubated in medium supplemented with serum and ascorbate showed that 8.1 +/- 1.1 microg PRG4/cm(2) area of meniscus surface was secreted over six days. These results demonstrate that PRG4 is synthesized and secreted by certain cell populations in the meniscus, and that PRG4 is present in the meniscus at surfaces and also internal fibers where it may contribute to boundary lubrication.

  10. Growth and metabolism of murine and bovine embryos in bovine uterine flushing-supplemented culture media.

    PubMed Central

    Rondeau, M; Guay, P; Goff, A K; Cooke, G M

    1996-01-01

    The aim of this study was to compare the development and metabolic activity of cultured murine and bovine embryos in 2 standard media (HAM F-10 and RPMI) in the presence or absence of bovine uterine flushings. Murine morulae (n = 653) and day 7 bovine embryos (n = 273) were cultured for 18 h or 36 h in either HAM F-10 or RPMI in the presence or absence of bovine uterine flushings. After culture, the development, quality, and metabolic activity (glucose utilization or methionine uptake and incorporation) of embryos was assessed. It was found that HAM F-10 (without uterine flushings) was a more suitable medium than RPMI for optimal development and metabolism of murine and bovine embryos. Poor quality and development, as well as decreased metabolism, were evident after culture of murine embryos in RPMI; in contrast, this medium had no adverse effects on bovine embryos in culture. Supplementation of HAM F-10 with bovine uterine flushings improved the growth of murine embryos and the protein synthesis (as measured by an increased methionine incorporation) for both murine and bovine embryos. However, supplementation with bovine uterine flushings could not overcome deficiencies of an inappropriate medium (RPMI) for murine embryos. Supplementation of a well-defined culture medium with uterine flushings increased metabolism of embryos in culture, and thus might help to increase pregnancy rates after transfer of such embryos to recipient cows. PMID:8825988

  11. Special tool kit aids heavily garmented workers

    NASA Technical Reports Server (NTRS)

    Holmes, A. E.

    1966-01-01

    Triangular aluminum tool kit, filled with polyurethane is constructed to receive various tools and hold them in a snug but quick-release fit as an aid to heavily gloved workers. The kit is designed to allow mounting within easily accessable reach and to provide protection of the tools during storage.

  12. Novel versatile smart phone based Microplate readers for on-site diagnoses.

    PubMed

    Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong

    2016-07-15

    Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. HNU-HANBY PCP IMMUNOASSAY TEST KIT - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    The HNU-Hanby pentachlorophenol (PCP) test kit rapidly analyzes for PCP in soil samples. The test kit can only detect those PCP carriers that contain aromatic compounds. The test kit estimates PCP concentrations in soil samples indirectly by measuring petroleum hydrocarbon carrie...

  14. Evaluation of Commercially Available Chikungunya Virus Immunoglobulin M Detection Assays

    PubMed Central

    Johnson, Barbara W.; Goodman, Christin H.; Holloway, Kimberly; de Salazar, P. Martinez; Valadere, Anne M.; Drebot, Michael A.

    2016-01-01

    Commercial chikungunya virus (CHIKV)–specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA had high performance at CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. PMID:26976887

  15. Blood collection kit for Space Lab 1

    NASA Image and Video Library

    1981-02-02

    S81-26158 (Feb 1981) --- A close-up view of a training version of a STS-40/SLS-1 blood kit. Blood samples from crewmembers are critical to a number of Space Life Sciences-1 (SLS-1) investigations. One day's collection equipment, color coded for each crewmember, is neatly organized in the kit.

  16. miR-137 downregulates c-kit expression in acute myeloid leukemia.

    PubMed

    Hu, Yanping; Dong, Xiaolong; Chu, Guoming; Lai, Guangrui; Zhang, Bijun; Wang, Leitong; Zhao, Yanyan

    2017-06-01

    The oncogene c-kit plays a vital role in the pathogenesis of acute myeloid leukemia (AML). However, the mechanism of microRNAs targeting c-kit in AML has not been determined in detail. Moreover, the role miR-137 in tumor cell proliferation remains controversial. The aim of this work was to verify whether miR-137 targets c-kit and to research the biological effects of restoring miR-137 expression in leukemia cells. We found that miR-137 binds specifically to the 3'-UTR of c-kit and suppresses the expression and activities of c-kit. There is a negative correlation between miR-137 and c-kit expression in both patients and cell lines determined by screening large clinical samples. We found that miR-137 can inhibit proliferation, promote apoptosis, and induce differentiation of c-kit+ AML cells. We determined that miR-137 can participate in the leukemogenesis by regulating c-kit, which could be used as a therapeutic target for acute myeloid leukemia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Absence of antibodies specific to Besnoitia spp. in European sheep and goats from areas in Spain where bovine besnoitiosis is endemic.

    PubMed

    Gutiérrez-Expósito, Daniel; Ortega-Mora, Luis Miguel; Ara, Victor; Marco, Ignasi; Lavín, Santiago; Carvajal-Valilla, Javier; Morales, Angel; Álvarez-García, Gema

    2017-01-01

    Besnoitia besnoiti and B. caprae, which infect bovids (cattle and antelopes) and goats, respectively, are responsible for besnoitiosis, a chronic and debilitating disease. Bovine besnoitiosis is considered to be a reemerging disease in Central and Western Europe. In addition, infection by Besnoitia spp. has been reported in reindeer from Sweden and Finland. Recently, the parasite was also detected in roe deer and red deer from Spain, where an interconnection between the domestic and sylvatic cycles of B. besnoiti has been presumed. In contrast, caprine besnoitiosis seems to be enzootic to Kenya and Iran. The presence of Besnoitia spp. in small domestic ruminants has never been explored in Europe, and the role that these species might play in the epidemiology of bovine besnoitiosis, as intermediate hosts or reservoirs of B. besnoiti, remains unknown. Herein, the first serosurvey conducted in European sheep and goats from areas in Spain where bovine besnoitiosis is endemic is described. Convenience sampling was conducted of 1943 sheep and 342 goats close to cattle from the Pyrenees and Central Spain that were infected with endemic Besnoitia spp. Serum samples were first analyzed by ELISA and then by confirmatory Western blot. Specific antibodies were not found in any sampled animal. Thus, sheep are unlikely to play a role in the epidemiology of bovine besnoitiosis, at least in the sampled areas. A larger serosurvey is necessary to determine whether goats might be a putative reservoir. To confirm the results of this study, sheep and goats should be further studied in other European countries and regions where their numbers are high and where bovine besnoitiosis is spreading.

  18. Rapid and Sensitive Colorimetric ELISA using Silver Nanoparticles, Microwaves and Split Ring Resonator Structures

    PubMed Central

    Addae, Sarah A.; Pinard, Melissa A.; Caglayan, Humeyra; Cakmakyapan, Semih; Caliskan, Deniz; Ozbay, Ekmel; Aslan, Kadir

    2010-01-01

    We report a new approach to colorimetric Enzyme-Linked Immunosorbent Assay (ELISA) that reduces the total assay time to < 2 min and the lower-detection-limit by 100-fold based on absorbance readout. The new approach combines the use of silver nanoparticles, microwaves and split ring resonators (SRR). The SRR structure is comprised of a square frame of copper thin film (30 µm thick, 1 mm wide, overall length of ~9.4 mm on each side) with a single split on one side, which was deposited onto a circuit board (2×2 cm2). A single micro-cuvette (10 µl volume capacity) was placed in the split of the SRR structures. Theoretical simulations predict that electric fields are focused in and above the micro-cuvette without the accumulation of electrical charge that breaks down the copper film. Subsequently, the walls and the bottom of the micro-cuvette were coated with silver nanoparticles using a modified Tollen’s reaction scheme. The silver nanoparticles served as a mediator for the creation of thermal gradient between the bioassay medium and the silver surface, where the bioassay is constructed. Upon exposure to low power microwave heating, the bioassay medium in the micro-cuvette was rapidly and uniformly heated by the focused electric fields. In addition, the creation of thermal gradient resulted in the rapid assembly of the proteins on the surface of silver nanoparticles without denaturing the proteins. The proof-of-principle of the new approach to ELISA was demonstrated for the detection of a model protein (biotinylated-bovine serum albumin, b-BSA). In this regard, the detection of b-BSA with bulk concentrations (1 µM to 1 pM) was carried out on commercially available 96-well high throughput screening (HTS) plates and silver nanoparticle-deposited SRR structures at room temperature and with microwave heating, respectively. While the room temperature bioassay (without microwave heating) took 70 min to complete, the identical bioassay took < 2 min to complete using

  19. [Development of surgical antibioprophylaxis kits: evaluation of the impact on prescribing habits].

    PubMed

    Aouizerate, P; Guizard, M

    2002-01-01

    In our hospital, surgical antibioprophylaxis (ATBP) was too often administered too late, thus raising the infectious risk. Antibiotic stocks of the anaesthesia department were also systematically used, instead of nominal prescriptions of these drugs. The pharmacy could neither charge antibiotics to each surgical department nor quantify and differentiate ATBP from curative antibiotic therapy. The pharmacy and anaesthesia departments therefore set out to standardize surgical ATBP, in order to adapt this treatment to each surgical indication, and particularly in the case of allergy to beta-lactamase antibiotics (second line treatment kits). Consequently, prescription forms were developed and supplied to each surgery department, as well as ATBP kits. The kits were prepared and distributed by the pharmacy, and comprised boxes containing antibiotics in sufficient quantities to respect the protocols approved by the French Society of Anaesthesia and Resuscitation (SFAR). A protocol describing prescriptions, dispensation and administration has been presented to physicians and nurses. Fifteen surgical departments were included in our study and 30 different kits were prepared. From 1998 to 2001, 5586 surgical operations required administration of a kit (second line treatment kits in 5% of cases): 1848 (33%) in visceral surgery; 764 (13.8%) in urology; 802 (14%) in orthopaedics; 13 (0.2%) in vascular and thoracic surgery; 1236 (22%) in ear-nose-throat (ENT), periodontics and ophtalmology, and 923 (17%) in gynaecology and obstetrics. 93% of filled prescriptions forms were spontaneously returned to the pharmacy, the others were obtained during the renewal of kit stocks. The cost (over 4 years) of ATBP was quantified: 157,871 F for the 15 departments included, 26,123 F in visceral surgery, 13,520 F in urology, 73,741 F in orthopaedics, 569 F in vascular surgery, 39,720 F in ENT/ophthalmology/periodontics and 4,198 F in gynaecology and obstetrics. According to the Altemeier

  20. The Use of Kits in the Analysis of Tissue Lipids Requires Validation.

    PubMed

    Rider, T; LeBoeuf, R C; Tso, Patrick; Jandacek, R J

    2016-04-01

    The ready availability and ease of use of kits for the measurement of serum lipids has greatly facilitated these measurements. In many cases it would be convenient to use these kits in the determination of lipid concentrations in tissues. The successful application of serum kits in tissue analysis requires that two important issues be considered. First, the solvent system for the extraction of the lipids and the solvent used for analysis by the kit must be compatible with the reactions in the kit. Second, the concentration range in the analyzed solution must be within the range for which the kit is used. We report here that lipids in liver and adipose tissues may be significantly underestimated by the use of some kits. We recommend that the use of kits for tissue analysis of lipids be validated for the specific analysis.

  1. [Determination of antiphospholipid antibodies in serum using ELISA].

    PubMed

    Fialová, L; Mikulíková, L; Malbohan, I; Průcha, M; Palecková, A; Cerný, V

    1994-05-01

    The authors compare two ELISA methods for the assessment of antiphospholipid antibodies, classes IgG and IgM, in serum: ELISA Pin Plate System ALPHA DIALAB Co. and the ELISA method developed in the Research Institute of Rheumatic Diseases. Both methods use cardiolipin as antigen. In the Pin Plate test the immunochemical reaction antigen/antibody does not take place at the surface of the pits of the microtitration plates but on the tip of the next plate. The results of examinations of antiphospholipid antibodies obtained by the tested methods are comparable, the Pin Plate test is quicker and more sensitive, but its price limits routine use.

  2. The value of molecular expression of KIT and KIT ligand analysed using real-time polymerase chain reaction and immunohistochemistry as a prognostic indicator for canine cutaneous mast cell tumours.

    PubMed

    Costa Casagrande, T A; de Oliveira Barros, L M; Fukumasu, H; Cogliati, B; Chaible, L M; Dagli, M L Z; Matera, J M

    2015-03-01

    This study investigated the correlation between KIT gene expression determined by immunohistochemistry and real-time polymerase chain reaction (RT-PCR) and the rate of tumour recurrence and tumour-related deaths in dogs affected with mast cell tumour (MCT). Kaplan-Meier curves were constructed to compare tumour recurrence and tumour-related death between patients. The log-rank test was used to check for significant differences between curves. KIT-I, KIT-II and KIT-III staining patterns were observed in 9 (11.11%), 50 (61.73%) and 22 (27.16%) tumours, respectively. Tumour recurrence rates and tumour-related deaths were not associated with KIT staining patterns (P = 0278, P > 0.05), KIT (P = 0.289, P > 0.05) or KIT ligand (P = 0.106, P > 0.05) gene expression. Despite the lack of association between KIT staining pattern and patient survival time, the results suggest a correlation between aberrant KIT localization and increased proliferative activity of MCTs. RT-PCR seems to be a sensible method for quantitative detection of KIT gene expression in canine MCT, although expressions levels are not correlated with prognosis. © 2013 Blackwell Publishing Ltd.

  3. Reprint of "CON4EI: Bovine Corneal Opacity and Permeability (BCOP) test for hazard identification and labelling of eye irritating chemicals".

    PubMed

    Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R

    2018-06-01

    Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Nociceptive tuning by stem cell factor/c-Kit signaling.

    PubMed

    Milenkovic, Nevena; Frahm, Christina; Gassmann, Max; Griffel, Carola; Erdmann, Bettina; Birchmeier, Carmen; Lewin, Gary R; Garratt, Alistair N

    2007-12-06

    The molecular mechanisms regulating the sensitivity of sensory circuits to environmental stimuli are poorly understood. We demonstrate here a central role for stem cell factor (SCF) and its receptor, c-Kit, in tuning the responsiveness of sensory neurons to natural stimuli. Mice lacking SCF/c-Kit signaling displayed profound thermal hypoalgesia, attributable to a marked elevation in the thermal threshold and reduction in spiking rate of heat-sensitive nociceptors. Acute activation of c-Kit by its ligand, SCF, resulted in a reduced thermal threshold and potentiation of heat-activated currents in isolated small-diameter neurons and thermal hyperalgesia in mice. SCF-induced thermal hyperalgesia required the TRP family cation channel TRPV1. Lack of c-Kit signaling during development resulted in hypersensitivity of discrete mechanoreceptive neuronal subtypes. Thus, c-Kit can now be grouped with a small family of receptor tyrosine kinases, including c-Ret and TrkA, that control the transduction properties of sensory neurons.

  5. Dynex: multiplex ELISA technology

    USDA-ARS?s Scientific Manuscript database

    Conventional enzyme linked immunosorbent assay (ELISA) is a gold standard for screening antibodies and testing for protein or antigen presence. A significant limitation of this assay resides in the fact that only one analyte can be assessed per microplate well. Here, we describe and investigate a ne...

  6. Directional and Attitude Stability Control Kit

    DTIC Science & Technology

    2014-07-01

    Pre-MRAP Vehicle Rollover Stats1 7/6/2014 DASK - Directional and Attitude Stability Control Kit 7 1: Joint Military Vehicle Working Group Army... contained in this report are those of the author(s) and should not contrued as an official Department of the Army position, policy or decision, unless so...Control Kit 3 8/14/2012 9 Statement of Problem Studied • We address the problem of maneuver-induced rollovers of ground vehicles in theatre. A bolt

  7. Receptor tyrosine kinase (c-Kit) inhibitors: a potential therapeutic target in cancer cells

    PubMed Central

    Abbaspour Babaei, Maryam; Kamalidehghan, Behnam; Saleem, Mohammad; Huri, Hasniza Zaman; Ahmadipour, Fatemeh

    2016-01-01

    c-Kit, a receptor tyrosine kinase, is involved in intracellular signaling, and the mutated form of c-Kit plays a crucial role in occurrence of some cancers. The function of c-Kit has led to the concept that inhibiting c-Kit kinase activity can be a target for cancer therapy. The promising results of inhibition of c-Kit for treatment of cancers have been observed in some cancers such as gastrointestinal stromal tumor, acute myeloid leukemia, melanoma, and other tumors, and these results have encouraged attempts toward improvement of using c-Kit as a capable target for cancer therapy. This paper presents the findings of previous studies regarding c-Kit as a receptor tyrosine kinase and an oncogene, as well as its gene targets and signaling pathways in normal and cancer cells. The c-Kit gene location, protein structure, and the role of c-Kit in normal cell have been discussed. Comprehending the molecular mechanism underlying c-Kit-mediated tumorogenesis is consequently essential and may lead to the identification of future novel drug targets. The potential mechanisms by which c-Kit induces cellular transformation have been described. This study aims to elucidate the function of c-Kit for future cancer therapy. In addition, it has c-Kit inhibitor drug properties and their functions have been listed in tables and demonstrated in schematic pictures. This review also has collected previous studies that targeted c-Kit as a novel strategy for cancer therapy. This paper further emphasizes the advantages of this approach, as well as the limitations that must be addressed in the future. Finally, although c-Kit is an attractive target for cancer therapy, based on the outcomes of treatment of patients with c-Kit inhibitors, it is unlikely that Kit inhibitors alone can lead to cure. It seems that c-Kit mutations alone are not sufficient for tumorogenesis, but do play a crucial role in cancer occurrence. PMID:27536065

  8. Test characteristics of milk amyloid A ELISA, somatic cell count, and bacteriological culture for detection of intramammary pathogens that cause subclinical mastitis.

    PubMed

    Jaeger, S; Virchow, F; Torgerson, P R; Bischoff, M; Biner, B; Hartnack, S; Rüegg, S R

    2017-09-01

    Bovine mastitis is an important disease in the dairy industry, causing economic losses as a result of withheld milk and treatment costs. Several studies have suggested milk amyloid A (MAA) as a promising biomarker in the diagnosis of mastitis. In the absence of a gold standard for diagnosis of subclinical mastitis, we estimated the diagnostic test accuracy of a commercial MAA-ELISA, somatic cell count (SCC), and bacteriological culture using Bayesian latent class modeling. We divided intramammary infections into 2 classes: those caused by major pathogens (e.g., Escherichia coli, Staphylococcus aureus, streptococci, and lacto-/enterococci) and those caused by all pathogens (major pathogens plus Corynebacterium bovis, coagulase-negative staphylococci, Bacillus spp., Streptomyces spp.). We applied the 3 diagnostic tests to all samples. Of 433 composite milk samples included in this study, 275 (63.5%) contained at least 1 colony of any bacterial species; of those, 56 contained major pathogens and 219 contained minor pathogens. The remaining 158 samples (36.5%) were sterile. We determined 2 different thresholds for the MAA-ELISA using Bayesian latent class modeling: 3.9 µg/mL to detect mastitis caused by major pathogens and 1.6 µg/mL to detect mastitis caused by all pathogens. The optimal SCC threshold for identification of subclinical mastitis was 150,000 cells/mL; this threshold led to higher specificity (Sp) than 100,000 cells/mL. Test accuracy for major-pathogen intramammary infections was as follows: SCC, sensitivity (Se) 92.6% and Sp 72.9%; MAA-ELISA, Se 81.4% and Sp 93.4%; bacteriological culture, Se 23.8% and Sp 95.2%. Test accuracy for all-pathogen intramammary infections was as follows: SCC, sensitivity 90.3% and Sp 71.8%; MAA-ELISA, Se 88.0% and Sp 65.2%; bacteriological culture, Se 83.8% and Sp 54.8%. We suggest the use of SCC and MAA-ELISA as a combined screening procedure for situations such as a Staphylococcus aureus control program. With Bayesian

  9. Prevalence of individual and bulk tank milk antibodies of bovine herpesvirus type 1 and its relation to milk quality parameters on dairy farms in Catalonia (north-east Spain)

    PubMed Central

    Armengol, Ramon; Villalba, Daniel; Coma, Ester; Porquet, Lourdes; Jubert, Anna

    2017-01-01

    Bovine herpesvirus type 1 (BoHV-1) is the causative agent for infectious bovine rhinotracheitis and infectious pustular vulvovaginitis in cows or balanoposthitis in bulls. In this study, individual and bulk tank milk (BTM) samples from 5 Catalan dairy farms with different control strategies against BoHV-1 were analysed during the course of a year for milk quality parameters and glycoprotein E (gE) antibodies. Detection of gE antibodies was carried out with ELISA techniques. Prevalence of BoHV-1 varied between farms, and was stable during the study in individual and BTM samples. Comparing the antibody results of samples with milk quality parameters, positive samples with higher levels of antibodies corresponded to lower lactose and to higher percentages of fat and somatic cells. PMID:28761669

  10. Sero-epidemiology and hemato-biochemical study of bovine leptospirosis in flood affected zone of Pakistan.

    PubMed

    Ijaz, Muhammad; Abbas, Syed Nazar; Farooqi, Shahid Hussain; Aqib, Amjad Islam; Anwar, Ghulam Ali; Rehman, Abdul; Ali, Muhammad Muddassir; Mehmood, Khalid; Khan, Amjad

    2018-01-01

    The bovine leptospirosis is an economically important zoonotic disease of flood affected areas worldwide, but scarce information is available about its epidemiology in Pakistan. This is a first study on sero-epidemiology of bovine leptospirosis in Pakistan. The objectives of this study were to investigate the sero-prevalence and associated risk factors of bovine leptospirosis in flood affected zone of Punjab, Pakistan. A total of 385 serum samples were randomly collected from four tehsils of district Muzaffargarh, Pakistan. The serum samples were subjected to indirect ELISA for the detection of anti-leptospira antibodies. The overall sero-prevalence of leptospirosis was 30.39%. The prevalence was significantly higher (p<0.001) in cattle (56.25%) than buffaloes (4.66%). The key risk factors identified based on multivariable logistic regression were; confined system of rearing, flooded area, and lesser to graduate level of education as risk factors for leptospirosis. The values of hematological parameters varied significantly (p<0.05) for Hb, TEC and PCV while there was no significant (p>0.05) difference among TLC values among sero-positive and sero-negative animals. The serum biochemical profile revealed significant differences (p<0.05) in values of ALT, AST and creatinine among the sero-positive and negative animals. Hence, it can be concluded that leptospirosis is an emerging and neglected disease in flood affected zone of Pakistan, and the disease needs to be explored comprehensively in other parts of the country to sort out solid strategies for its control and eradication. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. AN ELISA ASSAY FOR HEME OXYGENASE (HO-1)

    EPA Science Inventory

    An ELISA assay for heme oxygenase (HO-l )

    Abstract

    A double antibody capture ELISA for the HO-l protein has been developed to separately quantitate HO-I protein. The use of 2.5% NP40 detergent greatly assists in freeing HO-l protein from membranes and/or other cel...

  12. Comparison of DOT-ELISA and Standard-ELISA for Detection of the Vibrio cholerae Toxin in Culture Supernatants of Bacteria Isolated from Human and Environmental Samples.

    PubMed

    Meza-Lucas, Antonio; Pérez-Villagómez, María-Fernanda; Martínez-López, José-Patricio; García-Rodea, Ricardo; Martínez-Castelán, María-Guadalupe; Escobar-Gutiérrez, Alejandro; de-la-Rosa-Arana, Jorge-Luis; Villanueva-Zamudio, Altagracia

    2016-09-01

    A comparison of DOT-ELISA and Standard-ELISA was made for detection of Vibrio cholerae toxin in culture supernatants of bacteria isolated from human and environmental samples. A total of 293 supernatants were tested in a double blind assay. A correlation of 100 % was obtained between both techniques. The cholera toxin was found in 20 Inaba and 3 Ogawa strains. Positive samples were from seafood (17 samples), potable water (1 sample) and sewage (5 samples). The DOT-ELISA was useful as the standard-ELISA to confirm the presence of cholera toxin in the environmental samples.

  13. Vietnamese Culture Kit.

    ERIC Educational Resources Information Center

    Nguyen, Liem Thanh

    This booklet provides a brief description of the cultural background of the Vietnamese, the geography of the country of Vietnam, the history of the Vietnamese people, their language, beliefs, systems of values, religions, customs, feasts, and holidays. The kit is designed to provide American sponsors and teachers with meaningful information about…

  14. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  15. 21 CFR 864.1860 - Immunohistochemistry reagents and kits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Immunohistochemistry reagents and kits. (a) Identification. Immunohistochemistry test systems (IHC's) are in vitro... performance claims, which may be packaged with ancillary reagents in kits. Their intended use is to identify, by immunological techniques, antigens in tissues or cytologic specimens. Similar devices intended for...

  16. Antimicrobial activity of bovine NK-lysin-derived peptides on bovine respiratory pathogen Histophilus somni

    PubMed Central

    Falkenberg, Shollie M.; Briggs, Robert E.; Tatum, Fred M.; Sacco, Randy E.

    2017-01-01

    Bovine NK-lysins, which are functionally and structurally similar to human granulysin and porcine NK-lysin, are predominantly found in the granules of cytotoxic T-lymphocytes and NK-cells. Although antimicrobial activity of bovine NK-lysin has been assessed for several bacterial pathogens, not all the important bacterial pathogens that are involved in the bovine respiratory disease complex have been studied. Therefore the objective of the present study was to evaluate the antimicrobial activity of bovine NK-lysin-derived peptides on bovine respiratory pathogen Histophilus somni. Four, 30-mer peptides corresponding to the functional region of NK-lysin helices 2 and 3 were synthesized and assessed for antibacterial activity on four bovine pneumonic H. somni isolates. Although there were some differences in the efficiency of bactericidal activity among the NK-lysin peptides at lower concentrations (2–5 μM), all four peptides effectively killed most H. somni isolates at higher concentrations (10–30 μM) as determined by a bacterial killing assay. Confocal microscopic and flow cytometric analysis of Live/Dead Baclight stained H. somni (which were preincubated with NK-lysin peptides) were consistent with the killing assay findings and suggest NK-lysin peptides are bactericidal for H. somni. Among the four peptides, NK2A-derived peptide consistently showed the highest antimicrobial activity against all four H. somni isolates. Electron microscopic examination of H. somni following incubation with NK-lysin revealed extensive cell membrane damage, protrusions of outer membranes, and cytoplasmic content leakage. Taken together, the findings from this study clearly demonstrate the antimicrobial activity of all four bovine NK-lysin-derived peptides against bovine H. somni isolates. PMID:28827826

  17. Antimicrobial activity of bovine NK-lysin-derived peptides on bovine respiratory pathogen Histophilus somni.

    PubMed

    Dassanayake, Rohana P; Falkenberg, Shollie M; Briggs, Robert E; Tatum, Fred M; Sacco, Randy E

    2017-01-01

    Bovine NK-lysins, which are functionally and structurally similar to human granulysin and porcine NK-lysin, are predominantly found in the granules of cytotoxic T-lymphocytes and NK-cells. Although antimicrobial activity of bovine NK-lysin has been assessed for several bacterial pathogens, not all the important bacterial pathogens that are involved in the bovine respiratory disease complex have been studied. Therefore the objective of the present study was to evaluate the antimicrobial activity of bovine NK-lysin-derived peptides on bovine respiratory pathogen Histophilus somni. Four, 30-mer peptides corresponding to the functional region of NK-lysin helices 2 and 3 were synthesized and assessed for antibacterial activity on four bovine pneumonic H. somni isolates. Although there were some differences in the efficiency of bactericidal activity among the NK-lysin peptides at lower concentrations (2-5 μM), all four peptides effectively killed most H. somni isolates at higher concentrations (10-30 μM) as determined by a bacterial killing assay. Confocal microscopic and flow cytometric analysis of Live/Dead Baclight stained H. somni (which were preincubated with NK-lysin peptides) were consistent with the killing assay findings and suggest NK-lysin peptides are bactericidal for H. somni. Among the four peptides, NK2A-derived peptide consistently showed the highest antimicrobial activity against all four H. somni isolates. Electron microscopic examination of H. somni following incubation with NK-lysin revealed extensive cell membrane damage, protrusions of outer membranes, and cytoplasmic content leakage. Taken together, the findings from this study clearly demonstrate the antimicrobial activity of all four bovine NK-lysin-derived peptides against bovine H. somni isolates.

  18. Exploration of the assessment practices of elementary teachers using science kits

    NASA Astrophysics Data System (ADS)

    Scribner-Maclean, Michelle

    The purpose of the study was to determine the assessment literacy levels of elementary teachers who are experienced science kit users compared to those who are novice users as well as to compare assessment literacy levels of kit users to non kit users. Further, the study explored how teachers used assessment instruments in a classroom setting during kit-based science lessons. The study consisted of two parts. The population for Part One of this study was 47 elementary teachers from four communities in Northeastern Massachusetts who used Science, Technology, and Children (STC) kits for their classroom science instruction. Part Two of this study was conducted with four elementary teachers, two experienced kit users and two novice kit users, who were selected by their administrators. Data were collected for Part One of this study by use of the Teacher Assessment Questionnaire (TAQ), developed by Plake and Impara (1990), which provided a description of the assessment literacy levels of teachers. The assessment literacy levels of experienced kit users were compared to novice kit users by the t-Test for independent means. The assessment literacy levels of kit users and non kit users were also compared by use of the t-Test for independent means. For Part Two, classroom observations and teacher interviews were audio taped and transcribed. Each of these four teachers were also given the TAQ. Data for Part Two of the study were categorized and coded by Whittington's (1990) assessment literacy skills which are based upon the Standards for Teacher Competency of Educational Assessment of Students (STCEAS). Instances in which these skills occurred during classroom observations and pre- and post-lesson interviews were tabulated to create an overall picture of assessment literacy for each of the four teachers. The findings for Parts One and Two of this study indicate that there were differences in the assessment literacy scores for kit users and non kit users only for Standard Two

  19. Supply kits for antenatal and childbirth care: a systematic review.

    PubMed

    Aleman, Alicia; Tomasso, Giselle; Cafferata, María Luisa; Colomar, Mercedes; Betran, Ana Pilar

    2017-12-13

    It is critical to increase the uptake of interventions proven to be effective to improve maternal and perinatal outcomes. Supply kits have been suggested to be a feasible strategy designed to ensure timely availability and effective follow-up of care. We conducted a systematic review to summarize the evidence on the uptake, effectiveness and safety of supply kits for maternal care. MEDLINE, the Cochrane Pregnancy and Childbirth Group's Trials Register, Campbell Collaboration, Lilacs, Embase and unpublished studies were searched. Studies that reported the efficacy, safety and use of supply kits for maternal healthcare were eligible. Participants were pregnant women or in childbirth. Supply kits were defined as a collection of medicines, supplies or instruments packaged together with the aim of conducting a healthcare task. Two reviewers independently performed the screening, data extraction, and methodological and quality assessment. 24 studies were included: 4 of them were systematic reviews and 20 primary studies. Eighteen studies evaluated a so-called "clean delivery kit". In all but two studies, the kits were used by more than half of the participants. A meta-analysis was deemed inappropriate due to the heterogeneity in study design, in the components of the interventions implemented, in the content of the kits, and in outcomes. Nine studies assessed neonatal outcomes and found statistically significant reductions in cord infection, sepsis and tetanus-related mortality in the intervention group. Three studies showed evidence of reduced neonatal mortality (OR 0.52, 0.60 and 0.71) with statistically significant confidence intervals in all cases. Four studies reported odd ratios for maternal mortality, but only one showed evidence of a statistically significant decrease in this outcome but it was ascribed to hand washing prior to childbirth and not with the use of kits. This review suggests potential benefits in the use of supply kits to improve maternal and

  20. Evaluation of a Commercial Latex Agglutination Test Kit for Cryptococcal Antigen

    PubMed Central

    Kaufman, Leo; Cowart, Glenda; Blumer, Sharon; Stine, Amy; Wood, Ross

    1974-01-01

    Two dozen Crypto-LA kits for detecting Cryptococcus neoformans capsular polysaccharide antigens were evaluated. Ten kits proved reliable for detecting and titering antigen in clinical materials. Fourteen kits were found to be inadequate. PMID:4596394