Mason, Kathleen L; Gonzalez, Michael V; Chung, Chungwon; Mousel, Michelle R; White, Stephen N; Taylor, Joshua B; Scoles, Glen A
2017-09-01
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identified using nested PCR (nPCR) as the gold standard. Negative bovine control sera supplied with the kit were used to calculate % inhibition (%I), designated bovine control ELISA (BcELISA), and this was compared to %I calculated from negative ovine sera derived from hand-raised, pathogen-free sheep, designated ovine control ELISA (OcELISA). The receiver operating characteristics area under the curve was 1.0 with a p value <0.001 regardless of the source of the control sera. The cutoff values for negative BcELISA and OcELISA were <30%I and <27%I, respectively. Our work confirmed that this Anaplasma antibody cELISA kit version 2 can be used with the serum controls supplied in the kit to test for A. ovis antibody in domestic sheep. Furthermore, this work confirmed the historically high infection prevalence (>93%) at the U.S. Sheep Experiment Station (Dubois, Idaho), in spite of efforts to reduce the possibility for iatrogenic transmission there, suggesting high levels of tick-borne transmission.
Ivens, Katherine O; Baumert, Joseph L; Taylor, Steve L
2016-07-01
Numerous commercial enzyme-linked immunosorbent assay (ELISA) kits exist to quantitatively detect bovine milk residues in foods. Milk contains many proteins that can serve as ELISA targets including caseins (α-, β-, or κ-casein) and whey proteins (α-lactalbumin or β-lactoglobulin). Nine commercially-available milk ELISA kits were selected to compare the specificity and sensitivity with 5 purified milk proteins and 3 milk-derived ingredients. All of the milk kits were capable of quantifying nonfat dry milk (NFDM), but did not necessarily detect all individual protein fractions. While milk-derived ingredients were detected by the kits, their quantitation may be inaccurate due to the use of different calibrators, reference materials, and antibodies in kit development. The establishment of a standard reference material for the calibration of milk ELISA kits is increasingly important. The appropriate selection and understanding of milk ELISA kits for food analysis is critical to accurate quantification of milk residues and informed risk management decisions. © 2016 Institute of Food Technologists®
Scoles, Glen A; Goff, Will L; Lysyk, Timothy J; Lewis, Gregory S; Knowles, Donald P
2008-07-27
A commercially available (cELISA) kit for diagnosing Anaplasma marginale infection in cattle was validated for diagnosing A ovis infection in sheep using the bovine serum controls as supplied by the manufacturer (BcELISA) and sheep serum controls from pathogen-free sheep (OcELISA). True positives were identified using two previously established assays, a nested PCR (nPCR) test and an indirect immunofluorescent assay (IFA). The BcELISA was also applied to sera from various species of wild ruminants, comparing the results with the IFA. Receiver operating characteristic (ROC) analysis indicated that the predicted threshold inhibition for the BcELISA was 19.2. The sensitivity for the BcELISA was 98.2% and the specificity was 96.3%. The predicted threshold inhibition decreased to 14.3 for the OcELISA; the sensitivity was 96.5% and the specificity was 98.1%. There was >/=90% concordance between IFA and nPCR, as well as between the BcELISA at 19% inhibition cutoff and either IFA or PCR. Concordance between the cELISA and IFA using sera from elk, mule deer, bighorn sheep, pronghorn antelope, and black-tailed deer ranged from 64% to 100%. This commercially available cELISA test kit can be used very effectively to test domestic sheep for infection with A. ovis using the kit-supplied controls (i.e. the BcELISA) and a 19% inhibition cutoff; the kit may also be useful for detecting intra-erythrocytic Anaplasma infections in wild ruminants.
Singh, S V; Singh, A V; Singh, R; Sharma, S; Shukla, N; Misra, S; Singh, P K; Sohal, J S; Kumar, H; Patil, P K; Misra, P; Sandhu, K S
2008-09-01
Present pilot study is the first attempt in the country to estimate sero-prevalence of Bovine Johne's disease (BJD) by screening cattle and buffaloes representing large population belonging to farmer's and farm herds in the home tracts (Uttar Pradesh (UP) and Punjab) of Hariana cattle and Murrah buffaloes in North India. Indigenous and in-house plate ELISA kit (using protoplasmic antigen from native Mycobacterium avium subsp. paratuberculosis 'Bison type' strain of goat origin), originally developed for goats and sheep was standardized in bovines and used for screening. For this study, 33 villages of south and west UP were randomly selected and surveyed from 2001 to 2003. There were 7943 farmer's families having 38,251 livestock, including cattle, buffaloes, goats and sheep (per family 4.8% livestock). Numerically, buffaloes and cattle were 54.7% and 22.1%, respectively. Serum samples were collected from 726 animals (4.2% of 16, 981 livestock with 4375 farmer's families) located in 33 randomly surveyed villages. Serum samples (699), submitted to Epidemiology Department of Veterinary College (Punjab Agricultural University, Ludhiana), in the year 2004 by farmer's and organized farm herds (Buffaloes, 372, Cattle, 327), were screened by this ELISA kit. Soluble protoplasmic antigen was prepared from Map (S 5) 'Bison type' strain isolated from a terminally sick goat with Johne's disease. Of the total 1425 bovine (Buffaloes and cattle) serum samples screened using indigenous ELISA kit, sero-prevalence of Johne's disease was 29.0% (28.6% in buffalo and 29.8% in cattle) in Northern India. State-wise sero-prevalence was 31.9% and 23.3% in UP and Punjab, respectively. In UP, of the 601 randomly sampled buffaloes, sero-prevalence was 40.3% (16.6% in young and 40.9% adults) and 25.5% (10.5% in young and 26.3% adults) in south and west UP, respectively. Of the 125 cattle screened, sero-prevalence was 42.6% (nil in young and 44.4% adults) and 30.0% (nil in young and 30.6% adults) in south and west UP, respectively. Of the 699 serum samples screened from Ludhiana, Punjab, sero-prevalence of BJD was 23.0%. Sero-prevalence was 23.3% (12.1% in young and 24.4% in adults) and 26.9% (27.2% in young and 26.8% in adults) in buffaloes and cattle, respectively. High prevalence of BJD in buffaloes in native tract of Murrah breed, and Hariana breed of cattle correlated with poor per-animal productivity and BJD may be the major cause. Indigenous ELISA kit was rapid, economic and sensitive test for large-scale screening of buffaloes and cattle population against incurable BJD.
Casarin, Elisabetta; Lucchese, Laura; Grazioli, Santina; Facchin, Sonia; Realdon, Nicola; Brocchi, Emiliana; Morpurgo, Margherita; Nardelli, Stefano
2016-01-01
Diagnostic tests for veterinary surveillance programs should be efficient, easy to use and, possibly, economical. In this context, classic Enzyme linked ImmunoSorbent Assay (ELISA) remains the most common analytical platform employed for serological analyses. The analysis of pooled samples instead of individual ones is a common procedure that permits to certify, with one single test, entire herds as "disease-free". However, diagnostic tests for pooled samples need to be particularly sensitive, especially when the levels of disease markers are low, as in the case of anti-BoHV1 antibodies in milk as markers of Infectious Bovine Rhinotracheitis (IBR) disease. The avidin-nucleic-acid-nanoassembly (ANANAS) is a novel kind of signal amplification platform for immunodiagnostics based on colloidal poly-avidin nanoparticles that, using model analytes, was shown to strongly increase ELISA test performance as compared to monomeric avidin. Here, for the first time, we applied the ANANAS reagent integration in a real diagnostic context. The monoclonal 1G10 anti-bovine IgG1 antibody was biotinylated and integrated with the ANANAS reagents for indirect IBR diagnosis from pooled milk mimicking tank samples from herds with IBR prevalence between 1 to 8%. The sensitivity and specificity of the ANANAS integrated method was compared to that of a classic test based on the same 1G10 antibody directly linked to horseradish peroxidase, and a commercial IDEXX kit recently introduced in the market. ANANAS integration increased by 5-fold the sensitivity of the 1G10 mAb-based conventional ELISA without loosing specificity. When compared to the commercial kit, the 1G10-ANANAS integrated method was capable to detect the presence of anti-BHV1 antibodies from bulk milk of gE antibody positive animals with 2-fold higher sensitivity and similar specificity. The results demonstrate the potentials of this new amplification technology, which permits improving current classic ELISA sensitivity limits without the need for new hardware investments.
He, Shengfa; Li, Xin; Gao, Jinyan; Tong, Ping; Chen, Hongbing
2017-07-15
Bovine β-lactoglobulin (BLG) is the main allergen in cows' milk, and the most commonly used method for detecting BLG is enzyme-linked immunosorbent assay (ELISA). However, antibodies used in commercial ELISA kits do not recognize specifically BLG IgE epitopes. Here, an antibody specific to IgE linear epitopes for BLG was used to develop a sandwich ELISA using a rabbit anti-BLG polyclonal antibody. The linear range for BLG detection was 31.25-8000ng/mL and limit of detection was 1.96ng/mL. BLG content in dairy samples was determined, and there was a good agreement between this immunoassay and reversed-phase high-performance liquid chromatography with high recovery. Additionally, BLG content in food samples had an average recovery of 104.25%. Allergenic residues were also detected in hydrolyzed infant formulas. The method developed could be a practical approach to determine BLG and its allergenic residues in food with a high degree of sensitivity, reliability and recovery. Copyright © 2017 Elsevier Ltd. All rights reserved.
Gan, W; Zhou, X; Yang, H; Chen, H; Qiao, J; Khan, S H; Yang, L; Yin, X; Zhao, D
2013-08-03
The infection status of cattle for bovine tuberculosis (bTB) was determined by real-time PCR, comparing the levels of IFN-γ mRNA in blood cultures stimulated with either bovine or avian tuberculin with non-stimulated control (phosphate buffer saline, PBS) blood culture. Totally, 137 cattle were tested to validate the assay, in which 54 were IFN-γ real-time quantitative PCR (RT-qPCR) positive, while the remaining 83 were found negative. Meanwhile, the IFN-γ ELISA test was carried out using the Bovigam IFN-γ detection ELISA kit and these results were used as a standard. The results of the single intradermal tuberculin tests (SIDT) and IFN-γ RT-qPCR tests were compared and revealed that the RT-qPCR correlated better with the ELISA and its accuracy was higher than SIDT. This indicates the RT-qPCR is a useful diagnostic method for bTB in cattle. However, several limitations remain for our approach, such as lack of a TB lesions or postmortem test results as a gold standard. Further improvements should be made in the future to increase accuracy of diagnosis of bTB in cattle.
Natale, A; Bucci, G; Capello, K; Barberio, A; Tavella, A; Nardelli, S; Marangon, S; Ceglie, L
2012-07-01
The objective of this study was to evaluate the performance of the complement fixation test (CFT) with respect to ELISA for the serological diagnosis of Q fever and to assess the role of serology as a tool for the identification of the shedder status. During 2009-2010, sera from 9635 bovines and 3872 small ruminants (3057 goats and 815 sheep) were collected and analyzed with CFT and ELISA. In addition, 2256 bovine, 139 caprine and 72 ovine samples (individual and bulk tank milk samples, fetuses, vaginal swabs and placentae) were analyzed with a real-time PCR kit. The relative sensitivity (Se) and specificity (Sp) of CFT with respect to ELISA were Se 26.56% and Sp 99.71% for cattle and Se 9.96% and Sp 99.94% for small ruminants. To evaluate the correlation between serum-positive status and shedder status, the ELISA, CFT and real-time PCR results were compared. Due to the sampling method and the data storage system, the analysis of individual associations between the serological and molecular tests was possible only for some of the bovine samples. From a statistical point of view, no agreement was observed between the serological and molecular results obtained for fetus and vaginal swab samples. Slightly better agreement was observed between the serological and molecular results obtained for the individual milk samples and between the serological (at least one positive in the examined group) and molecular results for the bulk tank milk (BTM) samples. The CFT results exhibited a better correlation with the shedder status than did the ELISA results. Copyright © 2012 Elsevier Ltd. All rights reserved.
Serum samples can be substituted by plasma samples for the diagnosis of paratuberculosis.
Goodridge, Amador; Correa, Ricardo; Castro, Paul; Escobar, Cecilia; de Waard, Jacobus H
2013-10-01
Employing plasma samples rather than serum samples for serological paratuberculosis diagnosis is practical, especially when bovine TB is assessed in the same cattle herd with the gamma interferon bovine avian (IFN-γ BA) test. We demonstrate that antibody titers in serum and plasma samples, utilizing the PARACHECK(®) ELISA kit, are highly comparable (Cohen's kappa test, k=0.955). We conclude that serum can be replaced with plasma in this commercially available antibody detection assay resulting in working hour savings for sampling and blood sample work-up and cost reductions for materials and sample storage. Copyright © 2013 Elsevier B.V. All rights reserved.
Rehman, T; Khan, M N; Abbas, R Z; Babar, W; Sikandar, A; Zaman, M A
2016-07-01
A serological and coprological survey of fasciolosis was conducted in bovine hosts from the Sargodha district, Pakistan using excretory-secretory (ES) antigens of Fasciola gigantica from cattle and buffaloes. Livers, faecal and blood samples of 146 cattle and 184 buffaloes were collected from slaughterhouses and examined for the presence of any Fasciola in bile ducts and ova in faeces. Serum was separated. ES antigens were prepared by incubating adult Fasciola in phosphate-buffered saline for 6-8 h and then filtering using a 0.22-μm syringe filter. Checkerboard titration was performed and optimum concentrations of antigen and serum were determined. Sero-prevalence was found to be 50.00 and 38.35% in buffalo and cattle, respectively. Using liver examination as the gold standard, enzyme-linked immunosorbent assay (ELISA) sensitivity was found to be 100% in both buffalo and cattle as compared with that of coprological examination in buffalo (61.79%) and cattle (54.54%). This indigenous ELISA was also highly specific, with values of 96.84 and 98.90% in buffalo and cattle, respectively. Positive predictive values were calculated as 96.74 and 98.21% in buffalo and cattle, respectively, while negative predictive values were 100%. For the validation of indigenous ELISA in field surveys, faecal and blood samples were collected from six sub-districts (tehsils) in the district of Sargodha. Sera were screened for the presence of anti-fasciola antibodies using both the indigenous and commercial ELISA kits. While both kits were equally sensitive, the indigenous ELISA was found to be more specific. The highest prevalence of fasciolosis was found in December, as ascertained using both serological and coprological examination. Significant differences were found in prevalences of fasciolosis in different sub-districts and age groups, together with feeding and watering systems.
Sharma, Gaurav Kumar; Mohapatra, Jajati Keshari; Mahajan, Sonalika; Matura, Rakesh; Subramaniam, Saravanan; Pattnaik, Bramhadev
2014-10-01
Foot-and-mouth disease is a highly infectious and contagious disease of livestock animals with transboundary and economical importance. Animals in the endemic settings are regularly vaccinated in addition to intensive surveillance for control of the disease. Under intensive vaccination, detection of infected animals among the vaccinated population is essential to monitor the infection and to track down the virus movement. Sero-surveillance and retrospective disease diagnosis is performed primarily by detecting antibodies against non-structural proteins (NSPs) of FMD virus which are usually absent in the inactivated vaccine formulations. The study was conducted with an objective to compare simultaneously performance of six NSP ELISAs in detecting infected animals in the areas covered under intensive vaccination, and to assess their fit-for-purpose attribute for sero-surveillance of FMD in India. A panel of bovine serum samples consisting of samples collected from infected with FMDV, vaccinated and naive animals were constituted. In addition, samples collected at random from areas having varied FMD situation and vaccination coverage were tested simultaneously by the six NSP ELISAs to compare their performances. The four indigenous assays showed varying degrees of correlation with the two commercial kits. The study validated that, in all the groups of samples, the indigenous assays were equally sensitive and specific as the two commercial kits. Among all the six assays, PrioCheck and in-house 3ABC I-ELISAs showed maximum sensitivity for detection of infected animals, whereas 3AB3 I-ELISA and 3ABC C-ELISA showed maximum specificity. The study concluded that the in-house available assays are equally capable as the commercially available kits for differentiation of infected animals under intensive vaccination and identifies the 3AB3 I-ELISA with optimum sensitivity and specificity for the purpose of sero-surveillance in India. Copyright © 2014 Elsevier B.V. All rights reserved.
He, Shengfa; Li, Xin; Gao, Jinyan; Tong, Ping; Chen, Hongbing
2018-01-01
Bovine β-lactoglobulin (BLG) is the major allergen in cows' milk, and the specific epitope plays a key role in food allergy. Developing a method specifically bind to the IgE epitope is necessary for testing BLG and its allergenic residues. The monoclonal antibody (1G9) specific to the IgE linear epitope for BLG was identified as high affinity and specificity. Based on 1G9, a sensitive fluorescent sandwich enzyme-linked immunosorbent assay (sELISA) was successfully developed using catalase-mediated fluorescence quenching of thiolated CdTe quantum dots in the presence of hydrogen peroxide as fluorescent signal output. The fluorescent sELISA showed high sensitivity and specificity, the limit of detection was 0.49 ng mL -1 , which was 16-fold lower than horseradish peroxidase (HRP)-based sELISA. The linear range for BLG detection were 125-4000 ng mL -1 (r = 0.9939) and 0.48-62.5 ng mL -1 (r = 0.9919). The recoveries and coefficients of variation were 94.25-109.83% and 4.38-20.29%, respectively. Allergenic residues were also detected in hydrolysed infant formulas. The results of fluorescent sELISA showed good performance as HRP-based sELISA and commercial sELISA kit. This proposed fluorescent sELISA could be employed to detect BLG and its allergenic residues in food with highly sensitivity, reliability, and recovery. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Seroprevalence of viral and bacterial diseases among the bovines in Himachal Pradesh, India
Katoch, Shailja; Dohru, Shweta; Sharma, Mandeep; Vashist, Vikram; Chahota, Rajesh; Dhar, Prasenjit; Thakur, Aneesh; Verma, Subhash
2017-01-01
Aim: The study was designed to measure the seroprevalence of viral and bacterial diseases: Infectious bovine rhinotracheitis, bovine viral diarrhea, bovine leukemia, bovine parainfluenza, bovine respiratory syncytial disease, brucellosis, and paratuberculosis among bovine of Himachal Pradesh during the year 2013-2015. Materials and Methods: The serum samples were collected from seven districts of state, namely, Bilaspur, Kangra, Kinnaur, Lahul and Spiti, Mandi, Sirmour, and Solan. The samples were screened using indirect ELISA kits to measure the seroprevalence of viral and bacterial diseases. Results: The overall seroprevalence of infectious bovine rhinotracheitis was 24.24%, bovine viral diarrhea 1.52%, bovine leukemia 9.09%, bovine parainfluenza 57.58%, bovine respiratory syncytial disease 50%, brucellosis 19.69%, and paratuberculosis 9.09% in Himachal Pradesh. The seroprevalence of bovine rhinotracheitis, bovine leukemia, bovine parainfluenza, bovine respiratory syncytial disease, and paratuberculosis in the state varied significantly (p<0.01) while was insignificant for bovine viral diarrhea and brucellosis (p>0.01). Multiple seropositivity has been observed in this study. Bovine parainfluenza virus 3 was observed commonly in mixed infection with almost all viruses and bacteria under study. Conclusion: The viral and bacterial diseases are prevalent in the seven districts of Himachal Pradesh investigated in the study. Therefore, appropriate management practices and routine vaccination programs should be adopted to reduce the prevalence of these diseases. PMID:29391682
Evaluation of commercial ELISA kits for the detection of antibodies against bluetongue virus.
Niedbalski, W
2011-01-01
The aim of this study was to estimate the diagnostic value of different commercially available ELISA kits for the detection of bluetongue virus (BTV) antibodies in infected and vaccinated animals. The relative specificity of ELISA kits was evaluated using a panel of sera originating from healthy cattle, never vaccinated nor exposed to BTV. All ELISA kits applied had a high relative specificity (99.3 - 100%). The relative sensitivity of ELISA kits assessed using a panel of sera collected from BTV infected cattle was also high and similar for all the kits (97.3 - 100%). However, the relative sensitivity evaluated on the basis of testing vaccinated animals was different: the highest sensitivity was found for Ingenasa, PrioCHECK and ID VET ELISAs (96.5 - 98.3%). Slightly lower sensitivity was calculated for Pourquier and LSI kits (82.8% and 85.4%, respectively) and much lower sensitivity was found for VMRD ELISA kit (69.5%). The repeatability of BTV ELISA kits was expressed as a coefficient of variation (CV) of results of sera tested 5 times in the same day and in different days by the period of 2 months, by the same person, in the same conditions, and by using the same equipment. The CVs of sera tested in all ELISA kits ranged from 6.1 to 9.8% and were below 10% threshold adopted as a maximum for the acceptable repeatability of the method. In conclusion, it can be stated that the applied ELISA kits can be a valuable diagnostic tool for the serological monitoring studies in the BTV contaminated premises. All the methods are very specific and sensitive when testing BTV infected animals. Nevertheless, the Ingenasa and PrioCHECK can be the most useful in sero-surveillance of livestock following vaccination.
Baillargeon, Paul; Arango-Sabogal, Juan C; Wellemans, Vincent; Fecteau, Gilles
2017-04-01
The objective of this study was to determine if precolostral blood samples are useful to detect apparent fetal infections with bovine viral diarrhea (BVD) and infectious bovine rhinotracheitis (IBR) viruses. A convenience sample of 317 sera from 50 Canadian herds was used in the study. Antibody level was measured using 2 commercial IBR and BVD ELISA kits. Precolostral status of sera was confirmed on 304 samples using serum gamma-glutamyl transferase activity. Postcolostral serum samples yielded a higher proportion of positive results to IBR (OR = 86; 95% CI: 17.8 to 415.7) and BVD (OR = 199.3; 95% CI: 41.7 to 952.3) than did precolostral samples. All positive precolostral serum samples ( n = 7 of 304) originated from calves born to vaccinated cows. Postcolostral positive serum samples ( n = 11 of 13) originated mostly (60%) from calves born to non-vaccinated cows. Precolostral serum sampling can detect apparent fetal infections in a herd.
Herd-level risk factors for bovine viral diarrhea infection in cattle of Tamil Nadu.
Kumar, Subbiah Krishna; Palanivel, K M; Sukumar, K; Ronald, B Samuel Masilamoni; Selvaraju, G; Ponnudurai, G
2018-04-01
A cross-sectional study was carried out to identify risk factors for bovine viral diarrhea virus (BVDV) infection in 62 randomly selected dairy herds which were tested for BVD serum antibodies by using an indirect ELISA kit (IDEXX). Results from the chi-square test analysis were interpreted by analyzing by chi-square test. A sum of 500 sera samples were screened and 66 animals (13.20%) showed positive for BVDV antibody. Within herd, BVD seroprevalence was 12-65%. This study concluded that epidemiological risk factors like location, herd size, housing patterns like, tail to tail system, roofing pattern, distance between the manure pit and farm, and distance between farms were significantly associated with BVDV serological status (P < 0.05).
Yang, Ming; Parida, Satya; Salo, Tim; Hole, Kate; Velazquez-Salinas, Lauro
2015-01-01
Foot-and-mouth disease (FMD) is one of the most highly contagious and economically devastating diseases, and it severely constrains the international trade of animals. Vaccination against FMD is a key element in the control of FMD. However, vaccination of susceptible animals raises critical issues, such as the differentiation of infected animals from vaccinated animals. The current study developed a reliable and rapid test to detect antibodies against the conserved, nonstructural proteins (NSPs) of the FMD virus (FMDV) to distinguish infected animals from vaccinated animals. A monoclonal antibody (MAb) against the FMDV NSP 3B was produced. A competitive enzyme-linked immunosorbent assay (cELISA) for FMDV/NSP antibody detection was developed using a recombinant 3ABC protein as the antigen and the 3B-specific MAb. Sera collected from naive, FMDV experimentally infected, vaccinated carrier, and noncarrier animals were tested using the 3B cELISA. The diagnostic specificity was 99.4% for naive animals (cattle, pigs, and sheep) and 99.7% for vaccinated noncarrier animals. The diagnostic sensitivity was 100% for experimentally inoculated animals and 64% for vaccinated carrier animals. The performance of this 3B cELISA was compared to that of four commercial ELISA kits using a panel of serum samples established by the World Reference Laboratory for FMD at The Pirbright Institute, Pirbright, United Kingdom. The diagnostic sensitivity of the 3B cELISA for the panel of FMDV/NSP-positive bovine serum samples was 94%, which was comparable to or better than that of the commercially available NSP antibody detection kits. This 3B cELISA is a simple, reliable test to detect antibodies against FMDV nonstructural proteins. PMID:25651918
[Effect evaluation of three ELISA kits in detection of fasciolasis].
Ai, Lin; Chen, Mu-Xin; Chen, Shao-Hong; Chu, Yan-Hong; Cai, Yu-Chun; Zhou, Xiao-Nong; Chen, Jia-Xu
2013-04-01
To evaluate the effect of 3 ELISA kits on detection of human fasciolasis. Twenty-six serum samples from patients with fasciolasis, 180 serum samples from patients with other parasitic diseases as well as 26 serum samples from healthy people were detected by ELISA kits which using soluble antigen of Fasciola gigantica, Fasciola hepatica (Fg-ELISA and Fh-ELISA) as well as IgG antigen ELISA detection kits made by DRG company in Germany. The effects of the 3 kits were evaluated. The sensitivities of Fg-ELISA, Fh-ELISA, and DRG-ELISA were 100.0%, 80.8% (95% CI: 65.7%-95.9%) and 100.0%, respectively; the specificities of the three were 87.9% (95% CI: 83.5%-92.4%), 85.0%(95% CI: 80.1%-89.9%) and 83.5% (95% CI: 78.4%-88.6%), respectively, and Youden indexes of them were 0.88, 0.66 and 0.84, respectively. The detection rate of Fg-ELISA (100%) was significantly higher than that of Fh-ELISA (80.8%) (P < 0.05). The A absolute value (A/CO) of Fg-ELISA was 1.70, which was also significantly higher than the value of Fh-ELISA (1.18) (P < 0.000 1). Fg-ELISA has a good detection effect and low cost, and is more suitable than Fh-ELISA and DRG-ELISA for clinical sample tests as well as massive screening in fasciolasis endemic areas in southwest China.
Shiraishi, Rikiya; Nishiguchi, Akiko; Tsukamoto, Kenji; Muramatsu, Masatake
2012-09-01
We evaluated the utility of 5 commercial enzyme-linked immunosorbent assay (ELISA) kits for detecting antibodies to avian influenza viruses. The sensitivities and specificities of the ELISA kits were compared with those of the agar gel precipitation (AGP) and hemagglutination-inhibition (HI) tests. The results suggest that some ELISA kits might not be suitable for monitoring during the early stages of avian influenza virus infections. Therefore, ELISA kits should only be used in conjunction with a profound knowledge about monitoring of avian influenza.
Mohammadi, M; Talebkhan, Y; Khalili, G; Mahboudi, F; Massarrat, S; Zamaninia, L; Oghalaei, A
2008-01-01
To evaluate a home-made ELISA kit for detection of Helicobacter pylori (Hp) infection and comparison of its immunologic criteria with those of foreign commercial kits. A home-made IgG ELISA kit was developed using soluble antigenic fractions of Hp proteins. Confirmed sera were tested and serological criteria were evaluated through assessment of 199 serum samples. The accuracy, sensitivity and specificity values of home-made kit were 92, 92 and 90.4%, respectively. These immunologic criteria for Trinity kit were 95.2, 95.2 and 95% in comparison with IBL kit (91.3, 92.2 and 88.5%), BIOHIT kit (72.4, 41.6 and 94.1%) and HelicoBlot2.1 (94.2, 93.4 and 100%). Kappa agreement assessment demonstrated that two of the imported ELISA kits had fair to moderate agreement with the home-made kit while the other one had a poor agreement value. Apart from comparable values between the home-made kit and the most efficient imported kit (Trinity) there was significant cost benefit. Therefore, we recommend the home-made kit as a suitable substitution for detection of Hp infection in the Iranian population.
Iddawela, D; Ehambaram, K; Kumarasiri, P V; Wijesundera, S
2015-09-01
ELISA is the most widely used form of diagnosis for toxoplasmosis. Several commercial kits are currently used in Sri Lanka. However, these kits are not affordable in resource-limited settings. Objectives Aim of this study was to develop a cost effective in-house ELISA for the detection of Toxoplasma antibody and to estimate the diagnostic accuracy compared to a commercial kit. Vero cell lines were inoculated with tachyzoites and harvested after 2-6 days and sonicated to obtain somatic antigen. The antigen was used as coating material in ELISA to detect antibodies against T. gondii in patient sera. Hundred and three patients' sera were analysed by in-house ELISA and kit ELISA. Optical density (OD) values were analysed statistically. Toxoplasma IgG avidity test was used to determine the chronic and acute phase of infection. The optimum working dilutions for antigen was 0.846 μg/ml and for serum 1 in 100. The optimal cut-off values for the in-house ELISA within the range 0.85 to 0.98 at which the sensitivity was 95.3% and specificity was 98.3. The OD values of in-house ELISA were compared with OD values of kit ELISA and the results showed strong correlation between the two tests. The results of our study demonstrated that our in-house ELISA for detection of T. gondii antibody was as sensitive and specific as the commercial kit used in this study. Thus, the in-house ELISA is a useful, costeffective tool for diagnostic and screening purposes.
Derouin, F.; Garin, Y. J.; Buffard, C.; Berthelot, F.; Petithory, J. C.
1994-01-01
A collaborative study conducted by the French National Agency for Quality Control in Parasitology (CNQP) and various manufacturers of ELISA kits, represented by the Association of Laboratory Reagent Manufacturers (SFRL) compared the toxoplasmosis IgG antibody titres obtained with different ELISA-IgG kits and determined the relationships between the titres obtained by these techniques and the titre defined in international units (IU). Fifty-one serum samples with toxoplasmosis antibody titres ranging from 0 to 900 IU were tested in two successive studies with 16 ELISA-IgG kits. For the negative sera, false-positive reactions were observed with one kit. For the positive sera, the titres observed in ELISA were generally higher than those expressed in IU. Above 250 IU, the very wide variability of the titres found with the different ELISA kits renders any comparative analysis impossible. For titres below 250 IU, the results are sufficiently homogeneous to permit the use of regression analysis to study how the results for each ELISA kit compare with the mean results for the other kits. The slope of the line of regression shows a tendency to over-titration or under-titration compared with the results of the other manufacturers; the ordinate at the origin reflects the positivity threshold of the reaction and can be used to assess the risk of a lack of sensitivity (high threshold) or of specificity (threshold too low). On the whole, the trends revealed for a given manufacturer are constant from one study to the other. Within this range of titres, regression analysis also reveals the general tendency of ELISA kits to overestimate the titres by comparison with immunofluorescence.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:8205645
[Development of ELISA-kit of quantitative analysis for Zearalenone].
Wang, Yu-ping; Ji, Rong; Jiang, Tao; Kang, Wei-jun
2006-03-01
To develope a rapid, sensitive, quantitative ELISA-kit for Zearalenone and determine zearalenone in cereals. On the base of monoclonal antibodies against ZEN, apply indirect ELISA to study the performance parameter of the kit. The limited concentration of detection of the ELISA-kit was 1ng/ml, linear range was 1-200 ng/ml, the linear equation was Y = 0.99 - 0.40 x (R2 = 0.99). The inhibition concentration of 50% against ZEN was 16.3 ng/ml. The average recovery rate of spiked corn and wheat was 96.5% and 95.5%, respectively, the coefficient of variant was 13.2% and 10.9%, respectively. The kit can be stored at 4 degrees C over 6 months. The cross reaction rate with the other mycotoxins was less than 1%, and coefficient of variant within-laboratory and between-laboratory was less than 15% and less than 20%, respectively. Detecting the VICAM sample with ELISA method and HPLC method, the results were within the range of the sample, and there was no statistic difference between the two methods. This ELISA-kit was quick, sensitive, stable and specific and can be used to determine ZEN in cereals.
Sankar, Surya; Harshan, Hiron M; Somarajan, S R; Srivastava, S K
2010-06-01
A recombinant leptospiral lipoprotein, LigB, was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLigB IgG ELISA). The standard reference test (Microscopic agglutination test, MAT) of 200 serum samples from cattle suspected of leptospirosis showed that 95 (47.5%) samples had positive agglutination titres, which ranged from 100 to 1600. In rLigB IgG ELISA, 49% of the samples were positive. Sensitivity of IgG ELISA for 95 bovine sera, which had MAT titres of greater than or equal to 100, were 100%. ELISA showed a specificity of 97.1% with 105 bovine sera, which were negative at a 1:50 dilution in MAT for Leptospira interrogans serovars. The results of ELISA and MAT correspond very good. When analytical specificity of IgG ELISA was evaluated using bovine serum samples from animals showing the serum antibodies to other pathogens, no cross-reaction was observed. Thus the recombinant LigB IgG ELISA can be used instead of the MAT as an aid to the diagnosis of bovine leptospirosis. Copyright 2009. Published by Elsevier India Pvt Ltd.
Dombrowski, T.R.; Thurman, E.M.; Mohrman, G.B.
1996-01-01
A commercially available enzyme-linked immunosorbent assay (ELISA) plate kit for screening of cyclodiene insecticides (aldrin, chlordane, dieldrin, endosulfan, endrin, and heptachlor) was evaluated for sensitivity, cross reactivity, and overall performance using groundwater samples from a contaminated site. Ground-water contaminants included several pesticide compounds and their manufacturing byproducts, as well as many other organic and inorganic compounds. Cross-reactivity studies were carried out for the cyclodiene compounds, and results were compared to those listed by the manufacturer. Data obtained were used to evaluate the sensitivity of the ELISA kit to the cyclodiene compounds in ground water samples with a contaminated matrix. The method quantitation limit for the ELISA kit was 15 ??g/L (as chlordane). Of the 56 ground-water samples analyzed using the ELISA plate kits, more than 85% showed cyclodiene insecticide contamination. The ELISA kit showed excellent potential as a screening tool for sites with suspected groundwater contamination by insecticides.
Hermann, Laura L; Thaisomboonsuk, Butsaya; Poolpanichupatam, Yongyuth; Jarman, Richard G; Kalayanarooj, Siripen; Nisalak, Ananda; Yoon, In-Kyu; Fernandez, Stefan
2014-10-01
Currently, no dengue NS1 detection kit has regulatory approval for the diagnosis of acute dengue fever. Here we report the sensitivity and specificity of the InBios DEN Detect NS1 ELISA using a panel of well characterized human acute fever serum specimens. The InBios DENV Detect NS1 ELISA was tested using a panel composed of 334 serum specimens collected from acute febrile patients seeking care in a Bangkok hospital in 2010 and 2011. Of these patients, 314 were found to have acute dengue by either RT-PCR and/or anti-dengue IgM/IgG ELISA. Alongside the InBios NS1 ELISA kit, we compared the performance characteristics of the BioRad Platelia NS1 antigen kit. The InBios NS1 ELISA Ag kit had a higher overall sensitivity (86% vs 72.8%) but equal specificity (100%) compared to the BioRad Platelia kit. The serological status of the patient significantly influenced the outcome. In primary infections, the InBios NS1 kit demonstrated a higher sensitivity (98.8%) than in secondary infections (83.5%). We found significant variation in the sensitivity of the InBios NS1 ELISA kit depending on the serotype of the dengue virus and also found decreasing sensitivity the longer after the onset of illness, showing 100% sensitivity early during illness, but dropping below 50% by Day 7. The InBios NS1 ELISA kit demonstrated high accuracy when compared to the initial clinical diagnosis with greater than 85% agreement when patients were clinically diagnosed with dengue illness. Results presented here suggest the accurate detection of circulating dengue NS1 by the InBios DENV Detect NS1 ELISA can provide clinicians with a useful tool for diagnosis of early dengue infections.
Riffelmann, M.; Thiel, K.; Schmetz, J.; Wirsing von Koenig, C. H.
2010-01-01
Measuring antibodies to Bordetella pertussis antigens is mostly done by enzyme-linked immunosorbent assays (ELISAs). We compared the performance of ELISA kits that were commercially available in Germany. Eleven measured IgG antibodies, and nine measured IgA antibodies. An in-house ELISA with purified antigens served as a reference method. Samples included two WHO reference preparations, the former Food and Drug Administration (FDA)/Center for Biologics Evaluation and Research (CBER) reference preparations, serum samples from patients with clinically suspected pertussis, and serum samples from patients having received a combined tetanus, diphtheria, and pertussis (Tdap) vaccination. Kits using pertussis toxin (PT) as an antigen showed linearity compared to the WHO Reference preparation (r2 between 0.82 and 0.99), and these kits could quantify antibodies according to the reference preparation. ELISA kits using mixed antigens showed no linear correlation to the reference preparations. Patient results were compared to results of in-house ELISAs using a dual cutoff of either ≥100 IU/ml anti-PT IgG or ≥40 IU/ml anti-PT IgG together with ≥12 IU/ml anti-PT IgA. The sensitivities of kits measuring IgG antibodies ranged between 0.84 and 1.00. The specificities of kits using PT as an antigen were between 0.81 and 0.93. The specificities of kits using mixed antigens were between 0.51 and 0.59 and were thus not acceptable. The sensitivities of kits measuring IgA antibodies ranged between 0.53 and 0.73, and the specificities were between 0.67 and 0.94, indicating that IgA antibodies may be of limited diagnostic value. Our data suggest that ELISAs should use purified PT as an antigen and be standardized to the 1st International Reference preparation. PMID:20943873
Sunwoo, Hoon; Gujral, Naiyana; Suresh, Mavanur
2011-01-01
Two effective competitive and double antibody sandwich ELISA based on monoclonal (MAb) and chicken egg yolk IgY antibodies were developed to determine lactoferrin (LF) content in infant and milk formulas. Leghorn laying hens were immunized with purified bovine and human LFs to produce anti-bovine LF and anti-human LF IgY antibody in the egg yolk. After 5-8 weeks of the immunization, anti-LF IgY was extracted and analyzed by ELISA. Specific IgY antibodies against LFs cross reacted with human and bovine LFs, examined by ELISA and western-blot assay. Such cross-reactivity suggested the presence of common antigenic determinants between human and bovine LFs. An indirect competitive ELISA was preferred to quantify LF in milk and infant formulas, since the range of detection is 3.125-50 μg/mL, which is broader compared to the biotinylated ELISA system (5-50 ng/mL). As per the indirect competitive ELISA system, IgY at a concentration of the 150 μg/mL was incubated with various concentrations of bovine LF ranged from 0.003-100 μg/mL. The immunoassay was used to estimate the total bovine LF content in the milk samples and infant formulas, ranging from 49.28-80.96 μg/mL and 29.92-60.00 μg/mL, respectively.
Walraph, J; Zoche-Golob, V; Weber, J; Freick, M
2018-06-01
In cattle, indirect enzyme-linked immunosorbent assay (ELISA) tests are commonly used in serological routine diagnostics. In a longitudinal study design, changes in relative optical density (OD) from drying-off until week 11 after calving were analyzed in blood and milk samples from pluriparous dairy cows (n=21) using a commercial indirect anti-C. burnetii ELISA test. In a second part of this study, changes over time were evaluated in blood and milk samples of 11 of these cows in an indirect ELISA detecting anti-Bovine viral diarrhea virus (BVDV) antibodies. Regarding the cows which were still in the herd at the time of calving, blood serological qualitative changes from positive to negative or indeterminate were demonstrated in 7/20 cows (35%) for the anti-C. burnetii indirect ELISA and in 2/10 cows (20%) for the anti-BVDV indirect ELISA, respectively, during the period from 14days ante partum to calving. Relative OD in the anti-C. burnetii and the anti-BVDV indirect ELISA tests followed basically similar courses over time. In blood serum, relative OD initially increased after drying-off, before a drop around calving was observed. After the colostrum period, relative OD in blood serum showed an increase until week 11 of lactation. In colostrum samples, relative OD levels were higher than in milk samples obtained one day before drying-off. After parturition, relative OD in milk decreased until week 6 of lactation in the anti-C. burnetii indirect ELISA and until week 11 in the anti-BVDV indirect ELISA, respectively. In conclusion, blood serological investigations in periparturient dairy cows using indirect ELISA kits should be avoided. Copyright © 2018 Elsevier Ltd. All rights reserved.
Suslov, Anatoly P; Kuzin, Stanislav N; Golosova, Tatiana V; Shalunova, Nina V; Malyshev, Nikolai A; Sadikova, Natalia V; Vavilova, Lubov M; Somova, Anna V; Musina, Elena E; Ivanova, Maria V; Kipor, Tatiana T; Timonin, Igor M; Kuzina, Lubov E; Godkov, Mihail A; Bajenov, Alexei I; Nesterenko, Vladimir G
2002-07-01
When human sera samples are tested for anti-hepatitis C virus (HCV) antibodies using different ELISA kits as well as immunoblot assay kits discrepant results often occur. As a result the diagnostics of HCV infection in such sera remains unclear. The purpose of this investigation is to define the limits of HCV serodiagnostics. Overall 7 different test kits of domestic and foreign manufacturers were used for the sampled sera testing. Preliminary comparative study, using seroconversion panels PHV905, PHV907, PHV908 was performed and reference kit was chosen (Murex anti-HCV version 4) as the most sensitive kit on the base of this study results. Overall 1640 sera samples have been screened using different anti-HCV ELISA kits and 667 of them gave discrepant results in at least two kits. These sera were then tested using three anti-HCV ELISA kits (first set of 377 samples) or four anti-HCV ELISA kits (second set of 290 samples) at the conditions of reference laboratory. In the first set 17.2% samples remained discrepant and in the second set - 13.4%. "Discrepant" sera were further tested in RIBA 3.0 and INNO-LIA immunoblot confirmatory assays, but approximately 5-7% of them remained undetermined after all the tests. For the samples with signal-to-cutoff ratio higher than 3.0 high rate of result consistency by reference, ELISA routing and INNO-LIA immunoblot assay was observed. On the other hand the results of tests 27 "problematic" sera in RIBA 3.0 and INNO-LIA were consistent only in 55.5% cases. Analysis of the antigen spectrum reactive with antibodies in "problematic" sera, demonstrated predominance of Core, NS3 and NS4 antigens for sera, positive in RIBA 3.0 and Core and NS3 antigens for sera, positive in INNO-LIA. To overcome the problem of undetermined sera, methods based on other principles, as well as alternative criteria of HCV infection diagnostics are discussed.
Ivens, Katherine O; Baumert, Joseph L; Hutkins, Robert L; Taylor, Steve L
2017-11-01
Milk and milk products are among the most important allergenic food ingredients, both in the United States and throughout the world; cheeses are among the most important of these milk products. Milk contains several major antigenic proteins, each with differing susceptibilities to proteolytic enzymes. The extent of proteolysis in cheese varies as a result of conditions during manufacture and ripening. Proteolysis has the potential to degrade antigenic and allergenic epitopes that are important for residue detection and elicitation of allergic reactions. Commercial enzyme-linked immunosorbent assays (ELISAs) are not currently validated for use in detecting residues in hydrolyzed or fermented food products. Eighteen retail cheeses produced using 5 different styles of fermentation were investigated for detectable milk protein residues with 4 commercial ELISA kits. Mozzarella, Swiss, Blue, Limburger, and Brie cheeses were assessed. The Neogen Veratox® Casein and Neogen Veratox® Total Milk kits were capable of detecting milk residues in most cheeses evaluated, including blue-veined cheeses that exhibit extensive proteolysis. The other 2 ELISA kits evaluated, r-Biopharm® Fast Casein and ELISA Systems™ Casein, can detect milk residues in cheeses other than blue-veined varieties. ELISA results cannot be quantitatively compared among kits. The quantitative reliability of ELISA results in detection of cheese residues is questionable, but some methods are sufficiently robust to use as a semi-quantitative indication of proper allergen control for the validation of cleaning programs in industry settings. Many commercially available enzyme-linked immunosorbent assays (ELISAs) are not validated for detection of allergenic residues in fermented or hydrolyzed products. This research seeks to determine if commercial milk ELISAs can detect milk residues in varieties of cheese that have undergone different styles of fermentation and different degrees of proteolysis. Only certain milk ELISA kits are capable of detecting residues in all varieties of cheese. However, commercial milk ELISA kits are capable of semiquantitative detection of cheese residues in foods, or in industry settings for the validation of allergen cleaning programs. © 2017 Institute of Food Technologists®.
Matsuo, Toshihiro; Miyagawa, Jun-Ichiro; Kusunoki, Yoshiki; Miuchi, Masayuki; Ikawa, Takashi; Akagami, Takafumi; Tokuda, Masaru; Katsuno, Tomoyuki; Kushida, Akira; Inagaki, Takashi; Namba, Mitsuyoshi
2016-05-01
The aims of the present study were to investigate the performance of a novel sandwich enzyme-linked immunosorbent assay (ELISA) for measuring glucagon (1-29) with monoclonal antibodies against both the C- and N-terminal regions of glucagon (1-29), and to analyze the differences in plasma levels and responses of glucagon (1-29) to oral glucose loading in normal glucose tolerance (NGT) subjects and patients with type 2 diabetes mellitus. The cross-reactivity against proglucagon fragments using the ELISA kit and two types of conventional radioimmunoassay (RIA) kits was evaluated. A 75-g oral glucose tolerance test was carried out with NGT subjects and patients with type 2 diabetes mellitus, and the glucagon (1-29) concentration was measured using three types of kit. The ELISA kit clearly had the lowest cross-reactivity against miniglucagon (19-29) and glicentin (1-61). The oral glucose tolerance test was carried out with 30 NGT and 17 patients with type 2 diabetes mellitus. The glucagon (1-29) levels measured by the ELISA kit after glucose loading were significantly higher at all time-points in the type 2 diabetes mellitus group than in the NGT group. However, the glucagon (1-29) levels measured by one RIA kit were significantly higher in the NGT group, and those measured with the other RIA kit were approximately the same among the groups. The novel sandwich ELISA accurately determines plasma glucagon (1-29) concentrations with much less cross-reactivity against other proglucagon fragments than conventional RIA kits.
Development of an incurred cornbread model for gluten detection by immunoassays.
Sharma, Girdhari M; Khuda, Sefat E; Pereira, Marion; Slate, Andrew; Jackson, Lauren S; Pardo, Christopher; Williams, Kristina M; Whitaker, Thomas B
2013-12-11
Gluten that is present in food as a result of cross-contact or misbranding can cause severe health concerns to wheat-allergic and celiac patients. Immunoassays, such as enzyme-linked immunosorbent assay (ELISA) and lateral flow device (LFD), are commonly used to detect gluten traces in foods. However, the performance of immunoassays can be affected by non-assay-related factors, such as food matrix and processing conditions. Gluten (0-500 ppm) and wheat flour (20-1000 ppm) incurred cornbread was prepared at different incurred levels and baking conditions (204.4 °C for 20, 27, and 34 min) to study the accuracy and precision of gluten measurement by seven immunoassay kits (three LFD and four ELISA kits). The stability and immunoreactivity of gluten proteins, as measured by western blot using three different antibodies, were not adversely affected by the baking conditions. However, the gluten recovery varied depending upon the ELISA kit and the gluten source used to make the incurred cornbread, affecting the accuracy of gluten quantification (BioKits, 9-77%; Morinaga, 91-137%; R-Biopharm, 61-108%; and Romer Labs, 113-190%). Gluten recovery was reduced with increased baking time for most ELISA kits analyzed. Both the sampling and analytical variance increased with an increase in the gluten incurred level. The predicted analytical coefficient of variation associated with all ELISA kits was below 12% for all incurred levels, indicative of good analytical precision.
Maity, Susmita; Nandi, Srijita; Biswas, Subrata; Sadhukhan, Salil Kumar; Saha, Malay Kumar
2012-11-26
HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn't vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful.
2012-01-01
Background HIV, HBV and HCV pose a major public health problem throughout the world. Detection of infection markers for these agents is a major challenge for testing laboratories in a resource poor setting. As blood transfusion is an important activity saving millions of live every year, it also carries a risk of transfusion transmissible infections caused by these fatal blood borne pathogens if the quality of testing is compromised. Conventional ELISA is regarded as the mostly used screening technique but due to limitations like high cost, unavailability in many blood banks and testing sites, involvement of costly instruments, time taking nature and requirement of highly skilled personnel for interpretation, rapid tests are gaining more importance and warrants comparison of performance. Results A comparative study between these two techniques has been performed using commercially available diagnostic kits to assess their efficacy for detection of HIV, HBV and HCV infections. Rapid kits were more efficient in specificity with synthetic antigens along with high PPV than ELISA in most cases. Comparison between different ELISA kits revealed that Microlisa HIV and Hepalisa (J. Mitra & Co. Pvt. Ltd.); ERBA LISA HIV1 + 2, ERBA LISA Hepatitis B and ERBA LISA HCV (Transasia Bio-medicals Ltd.) gives uniform result with good performance in terms of sensitivity, specificity, PPV, NPV and efficiency, whereas, Microlisa HCV (J. Mitra & Co. Pvt. Ltd.), Microscreen HBsAg ELISA and INNOVA HCV (Span Diagnostics Ltd.) did not perform well. Rapid kits were also having high degree of sensitivity and specificity (100%) except in HIV Comb and HCV Comb (J. Mitra & Co. Pvt. Ltd.). The kit efficiency didn’t vary significantly among different companies and lots in all the cases except for HCV ELISA showing statistically significant variation (p < 0.01) among three kit types. Conclusions ELISA is a good screening assay for markers of HIV, HBV and HCV infections. Rapid tests are useful for further detection of false positive samples. ELISA seems the appropriate assay in blood bank. For availability of quality commercial diagnostic assays, evaluation of kit may be helpful. PMID:23181517
Bomfim, Maria Rosa Quaresma; Ko, Albert; Koury, Matilde Cota
2005-08-10
The recombinant leptospiral protein LipL32 was evaluated for use in the diagnosis of bovine leptospirosis by enzyme-linked immunosorbent assay (rLipL32 IgG ELISA). The microscopic agglutination test (MAT) of 150 serum samples from cattle suspected of leptospirosis showed that 125 (83.3%) samples had positive reciprocal agglutination titres, which ranged from 100 to 1600. The highest titres were observed for the serovars Hardjoprajitno and Bratislava. In the rLipL32 IgG ELISA, 83.3% of the samples were positive. The sensitivity of IgG ELISA for 125 bovine sera, which had MAT titres of greater than or equal to 100, was 100%. ELISA showed a specificity of 100% with 58 bovine sera, which were negative at a 1:50 dilution in the MAT for Leptospira interrogans serovars. When analytical specificity of the IgG ELISA was evaluted using 60 bovine serum samples from animals showing serum antibodies to other pathogens that cause abortion in cattle, such as Babesia sp., Anaplasma sp. and Brucella sp. and no cross-reaction was observed. The recombinant LipL32 IgG ELISA can be an alternative to the MAT for diagnosis of leptospiral infection in cattle.
USDA-ARS?s Scientific Manuscript database
An accurate and simple-to-perform new version of a competitive ELISA (cELISA) kit that became commercially available in 2015 for testing of cattle for antibody to Anaplasma marginale was validated for detection of Anaplasma ovis antibody in domestic sheep. True positives and negatives were identifie...
Zhou, Jie; Liao, Yu-xue; Chen, Zhong; Li, Yu-chun; Gao, Lu-Lu; Chen, Yi-xiong; Cai, Lian-gong; Chen, Qing; Yu, Shou-yi
2008-05-01
To develop an simple and sensitive method for detecting anti-coronavirus IgG antibodies in bat sera based on enzyme-linked immunosorbent assay (ELISA). A commercial ELISA kit for detecting SARS-CoV antibody was modified for detecting coronavirus antibodies in bat serum samples. The second antibody in the kit was replaced with horseradish peroxidase-conjugated protein-A (HRP-SPA) based on the characteristics of binding between Staphylococcus aureus protein A (SPA) and mammal IgG Fc fragment. The sera of 55 fulvous fruit bats (Rousettus dasymallus) were tested using the SPA-ELISA. The test results of the positive and negative controls in the kit and the serum samples from convalescent ;patient were consistent with expectation. Coronavirus antibody was detected in 2 out of the 55 bat serum samples. Serum neutralization test confirmed the validity of the SPA-ELISA method. This SPA-ELISA method is applicable for detecting coronavirus antibody in bat sera.
Ackermann-Gäumann, Rahel; Tritten, Marie-Lise; Hassan, Mona; Lienhard, Reto
2018-05-01
Tick-borne encephalitis (TBE) is endemic in many parts of Europe and Asia. The diagnosis of this disease is essentially based on the demonstration of specific antibodies. For reasons of simplicity, automatization and quick availability of test results, enzyme-linked immunosorbent assays (ELISAs) are the method of choice for serological diagnosis of TBE. Here, we evaluated three commercially available anti-TBEV IgG and IgM ELISAs using 251 serum samples: the SERION ELISA classic FSME Virus/TBE Virus IgG and IgM kit (Virion\\Serion), the RIDASCREEN ® FSME/TBE IgG and IgM kit (R-Biopharm), and the anti-FSME/TBE virus ELISA "Vienna" IgG/anti-FSME/TBE virus ELISA IgM kit (Euroimmun). In total, discrepant test results for IgG and/or IgM were observed for 37/251 (14.7 %) of tested samples; differences were statistically significant. Reference values defined by serum neutralization test (SNT, n = 25) or results provided by EQA organizers (n = 2) were established for a subset of samples. In relation to these values, false-positive results were observed mainly for Euroimmun Vienna IgG and RIDASCREEN IgG, whereas false-negative results were primarily observed for Virion\\Serion IgG and RIDASCREEN IgM kits. In routine diagnostics, specificity problems are of major relevance and may be addressed by analyzing the respective samples using SNT. Copyright © 2018 Elsevier GmbH. All rights reserved.
Apollonio, Luigino G; Whittall, Ian R; Pianca, Dennis J; Kyd, Jennelle M; Maher, William A
2007-05-01
The aim of this study was to evaluate the Bio-Quant Direct ELISA assays for amphetamine and methamphetamine in the routine presumptive screening of biological fluids. Standard concentration curves of the target analytes were assayed to assess sensitivity, and known concentrations of common amphetamine-type substances (ephedrine, pseudoephedrine, phentermine), designer analogues (MDA, MDMA, MDEA, MBDB, PMA, 4-MTA, 2CB), and putrefactive amines (phenylethylamine, putrescine, tryptamine, tyramine) were analyzed to determine cross-reactivity. Results of the standard curve studies show the capacity of both Direct ELISA kits to confidently detect down to 3 ng/mL interday (PBS matrix; CVs 6.3-15.5%). Cross-reactivity relative to that of 50 ng/mL preparations of the target compounds demonstrated that the Direct ELISA kit for amphetamine also detected MDA (282%), PMA (265%), 4-MTA (280%), and phentermine (61%), and the Direct ELISA for methamphetamine also assayed positive for MDMA (73%), MDEA (18%), pseudoephedrine (19%), MBDB (8%), and ephedrine (9%). Matrix studies demonstrated that both ELISA kits could be applied to screening of blood, urine, and saliva to a concentration of 6 ng/mL or lower. In conclusion, the Bio-Quant Direct ELISA kits for amphetamine and methamphetamine are fast and accurate and have demonstrated themselves to be useful tools in routine toxicological testing.
Joseph, Siju; Thomas, Naicy; Thangapandian, E; Singh, Vijendra P; Verma, Rishendra; Srivastava, S K
2012-03-01
A 21-kDa leptospiral lipoprotein (LipL21) was evaluated for its diagnostic potential to detect bovine leptospirosis by ELISA. Both native LipL21 (nLipL21) and recombinant LipL21 (rLipL21) proteins were tested and compared regarding diagnostic efficiency, and no statistically significant difference was observed. The sensitivity of rLipL21 ELISA for 62 microscopic agglutination test (MAT) positive sera was 100% and the specificity with 378 MAT negative sera was 97.09%. Thus, rLipL21 protein-based ELISA could be used as an alternative to MAT for the diagnosis of bovine leptospirosis.
Lauricella, Marta Alicia; Maidana, Cristina Graciela; Frias, Victoria Fragueiro; Romagosa, Carlo M.; Negri, Vanesa; Benedetti, Ruben; Sinagra, Angel J.; Luna, Concepcion; Tartaglino, Lilian; Laucella, Susana; Reed, Steven G.; Riarte, Adelina R.
2016-01-01
Direct observation of Leishmania parasites in tissue aspirates has shown low sensitivity for the detection of canine visceral leishmaniasis (VL). Therefore in the last quarter century immunoenzymatic tests have been developed to improve diagnosis. The purpose of this study was to develop a fast recombinant K28 antigen, naked-eye qualitative enzyme-linked immunosorbent assay (VL Ql-ELISA) and a quantitative version (VL Qt-ELISA), and to display it in a kit format, whose cutoff value (0.156) was selected as the most adequate one to differentiate reactive from nonreactive samples. Considering 167 cases and 300 controls, sensitivity was 91% for both assays and specificity was 100% and 98.7% in Ql-ELISA and Qt-ELISA, respectively. Positive predictive values were 100% and 97.4% for Ql-ELISA and Qt-ELISA, respectively, and negative predictive values were 95.2% for both ELISAs. Reagent stability, reliability studies, including periodic repetitions and retest of samples, cutoff selection, and comparison of rK28 ELISAs with rK39 immunochromatographic test, were the international criteria that supported the quality in both kits. The performance of both ELISA kits in this work confirmed their validity and emphasized their usefulness for low-to-medium complexity laboratories. PMID:27162270
Evaluation of Commercially Available Chikungunya Virus Immunoglobulin M Detection Assays
Johnson, Barbara W.; Goodman, Christin H.; Holloway, Kimberly; de Salazar, P. Martinez; Valadere, Anne M.; Drebot, Michael A.
2016-01-01
Commercial chikungunya virus (CHIKV)–specific IgM detection kits were evaluated at the Centers for Disease Control and Prevention (CDC), the Public Health Agency of Canada National Microbiology Laboratory, and the Caribbean Public Health Agency (CARPHA). The Euroimmun Anti-CHIKV IgM ELISA kit had ≥ 95% concordance with all three reference laboratory results. The limit of detection for low CHIK IgM+ samples, as measured by serial dilution of seven sera up to 1:12,800 ranged from 1:800 to 1:3,200. The Euroimmun IIFT kit evaluated at CDC and CARPHA performed well, but required more retesting of equivocal results. The InBios CHIKjj Detect MAC-ELISA had 100% and 98% concordance with CDC and CARPHA results, respectively, and had equal sensitivity to the CDC MAC-ELISA to 1:12,800 dilution in serially diluted samples. The Abcam Anti-CHIKV IgM ELISA had high performance at CARPHA, but at CDC, performance was inconsistent between lots. After replacement of the biotinylated IgM antibody controls with serum containing CHIKV-specific IgM and additional quality assurance/control measures, the Abcam kit was rereleased and reevaluated at CDC. The reformatted Abcam kit had 97% concordance with CDC results and limit of detection of 1:800 to 1:3,200. Two rapid tests and three other CHIKV MAC-ELISAs evaluated at CDC had low sensitivity, as the CDC CHIKV IgM in-house positive controls were below the level of detection. In conclusion, laboratories have options for CHIKV serological diagnosis using validated commercial kits. PMID:26976887
Therapeutic drug monitoring of infliximab: performance evaluation of three commercial ELISA kits.
Schmitz, Ellen M H; van de Kerkhof, Daan; Hamann, Dörte; van Dongen, Joost L J; Kuijper, Philip H M; Brunsveld, Luc; Scharnhorst, Volkher; Broeren, Maarten A C
2016-07-01
Therapeutic drug monitoring (TDM) of infliximab (IFX, Remicade®) can aid to optimize therapy efficacy. Many assays are available for this purpose. However, a reference standard is lacking. Therefore, we evaluated the analytical performance, agreement and clinically relevant differences of three commercially available IFX ELISA kits on an automated processing system. The kits of Theradiag (Lisa Tracker Infliximab), Progenika (Promonitor IFX) and apDia (Infliximab ELISA) were implemented on an automated processing system. Imprecision was determined by triplicate measurements of patient samples on five days. Agreement was evaluated by analysis of 30 patient samples and four spiked samples by the selected ELISA kits and the in-house IFX ELISA of Sanquin Diagnostics (Amsterdam, The Netherlands). Therapeutic consequences were evaluated by dividing patients into four treatment groups using cut-off levels of 1, 3 and 7 μg/mL and determining assay concordance. Within-run and between-run imprecision were acceptable (≤12% and ≤17%, respectively) within the quantification range of the selected ELISA kits. The apDia assay had the best precision and agreement to target values. Statistically significant differences were found between all assays except between Sanquin Diagnostics and the Lisa Tracker assay. The Promonitor assay measured the lowest IFX concentrations, the apDia assay the highest. When patients were classified in four treatment categories, 70% concordance was achieved. Although all assays are suitable for TDM, significant differences were observed in both imprecision and agreement. Therapeutic consequences were acceptable when patients were divided in treatment categories, but this could be improved by assay standardization.
Novel versatile smart phone based Microplate readers for on-site diagnoses.
Fu, Qiangqiang; Wu, Ze; Li, Xiuqing; Yao, Cuize; Yu, Shiting; Xiao, Wei; Tang, Yong
2016-07-15
Microplate readers are important diagnostic instruments, used intensively for various readout test kits (biochemical analysis kits and ELISA kits). However, due to their expensive and non-portability, commercial microplate readers are unavailable for home testing, community and rural hospitals, especially in developing countries. In this study, to provide a field-portable, cost-effective and versatile diagnostic tool, we reported a novel smart phone based microplate reader. The basic principle of this devise relies on a smart phone's optical sensor that measures transmitted light intensities of liquid samples. To prove the validity of these devises, developed smart phone based microplate readers were applied to readout results of various analytical targets. These targets included analanine aminotransferase (ALT; limit of detection (LOD) was 17.54 U/L), alkaline phosphatase (AKP; LOD was 15.56 U/L), creatinine (LOD was 1.35μM), bovine serum albumin (BSA; LOD was 0.0041mg/mL), prostate specific antigen (PSA; LOD was 0.76pg/mL), and ractopamine (Rac; LOD was 0.31ng/mL). The developed smart phone based microplate readers are versatile, portable, and inexpensive; they are unique because of their ability to perform under circumstances where resources and expertize are limited. Copyright © 2016 Elsevier B.V. All rights reserved.
Evaluation of ELISA tests specific for Shiga toxin 1 and 2 in food and water samples
USDA-ARS?s Scientific Manuscript database
Two enzyme-linked immunosorbent assay (ELISA) kits were evaluated for their effectiveness in detecting and differentiating between Shiga toxin 1 and 2 (Stx1 and Stx2) produced by Shiga toxin-producing E. coli (STEC) inoculated into food and water samples. Each kit incorporated monoclonal antibodies ...
Serosurvey of Crimean-Congo hemorrhagic fever virus in domestic animals, Gujarat, India, 2013.
Mourya, Devendra T; Yadav, Pragya D; Shete, Anita; Majumdar, Triparna D; Kanani, Amit; Kapadia, Dhirendra; Chandra, Vartika; Kachhiapatel, Anantdevesh J; Joshi, Pravinchandra T; Upadhyay, Kamalesh J; Dave, Paresh; Raval, Dinkar
2014-09-01
Crimean-Congo hemorrhagic fever (CCHF) is a tick-borne viral disease that causes a fatal hemorrhagic illness in humans. This disease is asymptomatic in animals. CCHF was first confirmed in a nosocomial outbreak in 2011 in Gujarat State. Another notifiable outbreak occurred in July, 2013, in Karyana Village, Amreli district, Gujarat State. Anti-CCHF virus (CCHFV) immunoglobulin G (IgG) antibodies were detected in domestic animals from the adjoining villages of the affected area, indicating a considerable amount of positivity against domestic animals. The present serosurvey was carried out to determine the prevalence of CCHFV among bovine, sheep, and goat populations from 15 districts of Gujarat State, India. A total of 1226 serum samples from domestic animals were screened for IgG antibodies using a CCHF animal IgG enzyme-linked immunosorbent assay (ELISA) kit from the Centers for Disease Control and Prevention. Antibodies were detected in all the 15 districts surveyed; with positivity of 12.09%, 41.21%, and 33.62% in bovine, sheep, and goat respectively. This necessitates the surveillance of CCHFV IgG antibodies in animals and hemorrhagic fever cases in human.
Evaluation of HIV/AIDS diagnostics kits and formulation of a testing strategy for Pakistan.
Waheed, Usman; Hayat, Khizar; Ahmad, Bashir; Waheed, Yasir; Zaheer, Hasan Abbas
2013-04-01
Rapid diagnosis of HIV/AIDS enables the development of prevention and treatment programmes but accurate, reliable and cost effective testing strategies should be used for testing of HIV/AIDS from a large population. To evaluate the performance and effectiveness of three assays for the diagnosis of HIV in comparison with Western blot and to formulate an alternative cost-effective confirmatory approach for HIV diagnosis. 472 specimens (serum) from a Pakistani population were evaluated. Two rapid HIV testing kits (Capillus, SD Bioline) and one ELISA (Vironostika Ag/Ab) kit were used to detect HIV. Results were compared with Western blot against which sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of all HIV assays were assessed. 280/472 (59.3%) of the samples were positive for antibodies against purified HIV-1 viral proteins. The sensitivity of SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100) while that of anti-HIV Capillus™ kit was 94.6% (95% CI; 91-96.8). The specificity of the Vironostika ELISA and anti-HIV Capillus™ kit was 100% (95% CI; 97-100) while specificity of SD Bioline was 98.4% (95% CI; 95-99). PPV was 100% (95% CI; 98-100%) for the anti-HIV Capillus™ and Vironostika ELISA and 98.9% (95% CI; 96-99%) for SD Bioline. NPV for SD Bioline and Vironostika ELISA was 100% (95% CI; 98-100%) and 92.7% for anti-HIV Capillus™ (95% CI; 88-96%). The sensitivity and specificity of all three kits were satisfactory compared to Western blot and could be used for effective diagnosis of HIV/AIDS in Pakistani population. Copyright © 2013 Elsevier B.V. All rights reserved.
Mariya, R; Chaudhary, Pallab; Kumar, A A; Thangapandian, E; Amutha, R; Srivastava, S K
2006-11-01
The efficacy of a recombinant leptospiral lipoprotein LipL41 as an antigen for conducting enzyme-linked immunosorbent assay (ELISA) for diagnosis of bovine leptospirosis was evaluated. Using known positive and known negative cattle sera the recombinant antigen was found to be highly reactive in the concentration of 100 ng/well. Using a total of 321 field cattle sera the sensitivity of ELISA as compared to microscopic agglutination test (MAT) was calculated to be 100% whereas the specificity was 85.3%. The seropositivity of leptospirosis among bovine population was found to be 21.18% having the predominance of serovars Sejroe and Pomona. It was concluded that rLipL41 protein could be a putative diagnostic candidate for serodiagnosis of bovine leptospirosis.
Parreño, Viviana; Romera, S Alejandra; Makek, Lucia; Rodriguez, Daniela; Malacari, Darío; Maidana, Silvina; Compaired, Diego; Combessies, Gustavo; Vena, María Marta; Garaicoechea, Lorena; Wigdorovitz, Andrés; Marangunich, Laura; Fernandez, Fernando
2010-10-01
Two ELISAs to quantify antibodies to BoHV-1 in the sera of cattle and immunized guinea pigs were developed and validated using ISO/IEC 17025 standards. The cut-off value of the assay was established at 20% positivity of a high positive control for screening of cattle. Using this threshold, the assay properly classified the OIE bovine reference sera EU1, EU2 and EU3. For vaccine potency testing, a cut-off of 40% was selected for both species. The reliability of the assays, given by their diagnostic sensitivity and specificity, using the threshold of 40% was 89.7% and 100%, respectively, for bovines and 94.9% and 100% for guinea pigs, respectively. There was almost perfect agreement between the ELISA and virus neutralization results. In addition, after vaccination, there was a good correlation between the neutralizing and ELISA antibody titers of the serum from the same bovine or guinea pig, sampled at 60 and 30 days post-vaccination, respectively (R(bovine)=0.88, R(guinea pig)=0.92; p<0.0001). A similar correlation was observed when analyzing the mean antibody titers of groups of vaccinated animals (R(bovine)=0.95 and R(guinea pig)=0.97; p<0.0001), indicating the relevance of the ELISAs for batch to batch vaccine potency testing in the target species and in the laboratory animal model. The intermediate precision of the assays expressed as the relative coefficient of variation (CV) of the positive control assayed over a 3-year period in the same laboratory was 22.2% for bovines and 23.1% for guinea pigs. The reproducibility of both techniques obtained in inter-laboratory assays was CV=12.4% for bovines and CV approximately 0 for guinea pigs, which met the requirements of the OIE (CV<30%). The validated ELISAs represent important methods for vaccine potency testing and for controlling BoHV-1 infections. Copyright (c) 2010 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2012 CFR
2012-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2013 CFR
2013-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2010 CFR
2010-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2014 CFR
2014-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Code of Federal Regulations, 2011 CFR
2011-01-01
...) Enzyme-linked immunosorbent assay (ELISA). ELISA must be conducted using test kits approved by the... conducted on all ELISA-positive samples. (B) The AGID test must be conducted using reagents approved by the...
Yang, Mei; Wang, Zhuoya; Hao, Wei; Wang, Yanfang; Huang, Li; Cai, Jianpiao; Jiang, Lingxiao; Che, Xiaoyan; Zhong, Xiaozhu; Yu, Nan
2014-05-01
To establish two double-antigen sandwich ELISA systems to detect anti-Afmp1cr and Afmp2cr antibodies of Aspergillus fumigatus. Recombinant Afmp1cr and Afmp2cr proteins of A.fumigatus expressed in Pichia pastoris were obtained. Double-antigen sandwich ELISA systems for detecting specific anti-Afmp1cr and anti-Afmp2cr antibodies were developed after chessboard titrating to determine the appropriate concentrations of the recombinant proteins and HRP-labeled proteins. The sensitivity of the assay was evaluated using serum samples of rabbits immunized with Afmp1cr and Afmp2cr. The specificity of the assay was evaluated by detecting serum samples from healthy donors and patients with other pathogenic fungal and baterial infections. The performance of the two ELISA kits was furthered evaluated using serum samples from patients with suspected Aspergillus infection. The established ELISA kits were capable of detecting anti-Afmp1cr and anti-Afmp2cr antibodies in immunized rabbit serum at the maximum dilutions of 800 and 3200, respectively. No cross-reactivity was observed in detecting serum from patients with other pathogenic fungal or bactetial infections. Both of the two kits yielded positive results in sera from two established Aspergillus-infected cases and a suspected case. Two antibody-capture ELISA kits were developed for the laboratory diagnosis of A.fumigatus infection and can be potentially useful in the clinical diagnosis of Aspergillosis infections.
Garcia, Hector H; Castillo, Yesenia; Gonzales, Isidro; Bustos, Javier A; Saavedra, Herbert; Jacob, Louis; Del Brutto, Oscar H; Wilkins, Patricia P; Gonzalez, Armando E; Gilman, Robert H
2018-01-01
To evaluate the diagnostic performance of two commercially available ELISA kits, Novalisa ® and Ridascreen ® , for the detection of antibodies to Taenia solium, compared to serological diagnosis of neurocysticercosis (NCC) by LLGP-EITB (electro-immunotransfer blot assay using lentil-lectin purified glycoprotein antigens). Archive serum samples from patients with viable NCC (n = 45) or resolved, calcified NCC (n = 45), as well as sera from patients with other cestode parasites (hymenolepiasis, n = 45 and cystic hydatid disease, n = 45), were evaluated for cysticercosis antibody detection using two ELISA kits, Novalisa ® and Ridascreen ® . All NCC samples had previously tested positive, and all samples from heterologous infections were negative on LLGP-EITB for cysticercosis. Positive rates were calculated by kit and sample group and compared between the two kits. Compared to LLGP-EITB, the sensitivity of both ELISA assays to detect specific antibodies in patients with viable NCC was low (44.4% and 22.2%), and for calcified NCC, it was only 6.7% and 4.5%. Sera from patients with cystic hydatid disease were highly cross-reactive in both ELISA assays (38/45, 84.4%; and 25/45, 55.6%). Sera from patients with hymenolepiasis cross-reacted in five cases in one of the assays (11.1%) and in only one sample with the second assay (2.2%). The performance of Novalisa ® and Ridascreen ® was poor. Antibody ELISA detection cannot be recommended for the diagnosis of neurocysticercosis. © 2017 John Wiley & Sons Ltd.
Abe, Takeo; Tsunoda, Shinichiro; Nishioka, Aki; Azuma, Kouta; Tsuboi, Kazuyuki; Ogita, Chie; Yokoyama, Yuichi; Furukawa, Tetsuya; Maruoka, Momo; Tamura, Masao; Yoshikawa, Takahiro; Saito, Atsushi; Sekiguchi, Masahiro; Azuma, Naoto; Kitano, Masayasu; Matsui, Kiyoshi; Hosono, Yuji; Nakashima, Ran; Ohmura, Koichiro; Mimori, Tsuneyo; Sano, Hajime
2016-01-01
Anti-aminoacyl-tRNA synthetase (ARS) antibody is one of the myositis-specific autoantibodies to make a diagnosis of polymyositis (PM) and dermatomyositis (DM). Recently a new enzyme-linked immunosorbent assay (ELISA) kit of concurrently detected anti-ARS antibodies (anti-Jo-1, anti-PL-7, anti-PL-12, anti-EJ and anti-KS) have become to measure in the clinical setting. To evaluate the reliability of this ELISA kit, we measured anti-ARS antibodies in 75 PM and DM patients using by this ELISA assay and compared them with the results by RNA immunoprecipitation assay. Between the measurements of anti-PL-7, anti-PL-12, anti-EJ and anti-KS autoantibodies by ELISA assay and RNA-IP assay, the concordance rate of reproducibility is 95.1% and the positive agreement rate is 90.9% and negative agreement rate is 96.0% and kappa statistic is 0.841. Between the measurements of existing anti-Jo-1 antibody ELISA kit and anti-ARS antibody ELISA kit, the concordance rate of reproducibility is 96.9%, the positive agreement rate is 100%, negative agreement rate is 96.1% and kappa statistic is 0.909. The lung involvement in patients with PM and DM patients are positive of anti-ARS antibodies and anti-melanoma differentiation associated gene5 (MDA5) antibody at a rate around 70%. Then most life-threatening ILD with anti-MDA5 positive clinically amyopathic dermatomyositis patients could be highly guessed when anti-ARS antibodies are negative.
Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka
2018-04-09
To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.
[Comparison of Dengue viral nonstructural protein 1 antigen testing kits].
Wu, D; Zhao, L Z; Wu, Y H; Zhang, H; Zhang, M; Tan, Q Q; Zhou, H Q; Zhang, F C; He, J F
2018-02-06
Objective: To investigate the sensitivity and specificity of commercial nonstructural protein 1 (NS1) testing kits for Dengue fever diagnose, and provide the evidence for diagnostic criteria revision. Methods: 300 PCR or virus isolation positive blood samples for dengue virus were collected from sentinel hospitals for dengue surveillance in Guangzhou, Dongguang and Zhongshang from May 2015 to Nov. 2016. At the same time, 308 PCR negative samples for Dengue virus were collected as control group. The information of the sample was collected using questionnaires. These samples were tested using imported and domestic ELISA and the colloidal gold-labeled kits that were widely used for detecting dengue NS1. Sensitivity, specificity and coincidence were calculated and analyzed, and Z hongshan's result was regarded as the reslut of the third part. Results: The positive group includes 133 males and 167 females, average ages are 47.2±13.3, 179, 110 and 11 of them is Dengue Ⅰ, Ⅱ and Ⅲ respectively. The negative group includes 154 males and 154 females, average ages are (40.1±11.6) years old. The sensitivity of domestic ELISA Kits (94.5%) is less than imported (99.5%), and the result has statistical significance (χ(2)=8.59, P= 0.030), the specificity is 99.7% and 97.7% respectively; The sensitivity of imported and domestic the colloidal gold-labeled Kits is 97.5% and 96.5% respectively, both of specificities are 100%. The sensitivity and specificity of Dengue Ⅰ for NS1 test are more than 97.0%. The sensitivity of domestic ELISA and gold-labeled Kits is 90.0% and 95.0%, and the specificity is 96.8% and 100% respectively for Dengue Ⅱ test. The sensitivity of imported ELISA and gold-labeled Kits is 100% and 98.0%, and the specificity is 99.4% and 100% respectively for Dengue Ⅱ test. The result of the third party show the sensitivity and specificity of domestic ELISA and gold-labeled Kits are 90.0% and 98.0%, the differences has statistical significance (χ(2)=5.67, P= 0.020). Conclusion: NS1 testing can be used as early dengue fever diagnose for higher sensitivity and specificity.
Development of an Indirect ELISA for Serological Diagnosis of Bovine herpesvirus 5
Campos, Fabrício S.; da Rosa, Matheus C.; Finger, Paula F.; de Oliveira, Patricia D.; Conceição, Fabricio R.; Fischer, Geferson; Roehe, Paulo M.; Leite, Fábio P. L.
2016-01-01
Bovine herpesviruses 1 and 5 (BoHV-1 and BoHV-5) are economically important pathogens, associated with a variety of clinical syndromes, including respiratory and genital disease, reproductive failure and meningoencephalitis. The standard serological assay to diagnose BoHV-1 and BoHV-5 infections is the virus neutralization test (VNT), a time consuming procedure that requires manipulation of infectious virus. In the present study a highly sensitive and specific single dilution indirect ELISA was developed using recombinant glycoprotein D from BoHV-5 as antigen (rgD5ELISA). Bovine serum samples (n = 450) were screened by VNT against BoHV-5a and by rgD5ELISA. Compared with the VNT, the rgD5ELISA demonstrated accuracy of 99.8%, with 100% sensitivity, 96.7% specificity and coefficient of agreement between the tests of 0.954. The rgD5ELISA described here shows excellent agreement with the VNT and is shown to be a simple, convenient, specific and highly sensitive virus-free assay for detection of serum antibodies to BoHV-5. PMID:26866923
Waner, T; Mazar, S; Nachmias, E; Keren-Kornblatt, E; Harrus, S
2003-05-10
A dot ELISA for the detection of immunoglobulin M (IgM) antibodies to canine distemper virus (CDC) and canine parvovirus (CPV) was assessed. The titres of IgM antibodies to CDV and CPV in 100 dogs were measured by the Immunocomb ELISA kit and compared with the results derived from the immunofluorescence assay (IFA). There was a strong correlation between the results of the dot ELISA technique and the IFA (P < 0.001). The dot ELISA kit was also used to assess the changes in the levels of immunoglobulin G (IgG) and IgM antibodies to CPV and CDV in 10 puppies vaccinated with a polyvalent vaccine. High levels of IgM antibodies to CPV were first detected seven days after they were vaccinated, and after nine days all the pups had high titres of IgG antibodies to CPV. High levels of IgM antibodies to CDV were detected after nine days and the highest average titres were recorded after 12 days. IgG antibodies to CDV were present from nine days after vaccination.
Pereira, Valeriana Valadares; Conceição, Abiqueila da Silva; Maximiano, Leandro Henrique Silva; Belligoli, Leonardo de Queiroz Gomes; Silva, Eduardo Sergio da
2014-01-01
Epidemiological studies on amebiasis have been reassessed since Entamoeba histolytica and E. dispar were first recognized as distinct species. Because the morphological similarity of these species renders microscopic diagnosis unreliable, additional tools are required to discriminate between Entamoeba species. The objectives of our study were to compare microscopy with ELISA kit (IVD®) results, to diagnose E. histolytica infection, and to determine the prevalence of amebiasis in a sample of students from southeastern Brazil. In this study, diagnosis was based on microscopy due to its capacity for revealing potential cysts/trophozoites and on two commercial kits for antigen detection in stool samples. For 1,403 samples collected from students aged 6 to 14 years who were living in Divinópolis, Minas Gerais, Brazil, microscopy underestimated the number of individuals infected with E. histolytica/E. dispar (5.7% prevalence) compared with the ELISA kit (IVD®)-based diagnoses (15.7% for E. histolytica/E. dispar). A comparison of the ELISA (IVD®) and light microscopy results returned a 20% sensitivity, 97% specificity, low positive predictive value, and high negative predictive value for microscopy. An ELISA kit (TechLab®) that was specific for E. histolytica detected a 3.1% (43/1403) prevalence for E. histolytica infection. The ELISA kit (IVD®) can be used as an alternative screening tool. The high prevalence of E. histolytica infection detected in this study warrants the implementation of actions directed toward health promotion and preventive measures.
Gaudin, V; Hedou, C; Rault, A; Sanders, P; Verdon, E
2009-04-01
The screening of antimicrobial residues in eggs is an especially important subject. Three different commercial kits for the screening of sulphonamides and other antimicrobials in eggs were validated in accordance with Decision 2002/657/EC: one enzyme-linked immunoabsorbant assay (ELISA) kit multi-sulphonamides (from RAISIO Diagnostics) and two microbiological tests (a Premi test from DSM and an Explorer kit from Zeu-Inmunotec). The false-positive rates were lower than 2% for all kits. The detection capabilities (CCbeta) have to be as low as possible for banned substances and lower than the maximum residue limit (MRL) when MRLs have been set. The sensitivity of the Premi test was better than that of the Explorer test, probably because of the dilution of the eggs before the Explorer test was used. The CCbeta values towards most of the tested sulphonamides were satisfactory with the Premi test (< or = 100 microg kg(-1)). Performance in a proficiency test for the detection of sulphonamides in eggs with the Premi test confirmed these results. The detection capabilities of tetracycline and doxycycline were at the level of the MRL or twice the MRL maximum. The detection capabilities for chlortetracycline and oxytetracycline were higher (four to six times the MRL). The detection capabilities for amoxicillin, neomycin, tylosin and erythromycin were lower than their respective MRLs. Detection capabilities for sulphonamides were much lower for the ELISA kit than for microbiological tests. The ELISA kit could be recommended for the targeted screening of sulphonamides in eggs. On the other hand, the Explorer and Premi tests could be used as wide screening tests allowing the detection of most of the antimicrobial families.
Chen, Hsiao Ying; Tran, Hung; Foo, Ling Yann; Sew, Tracey Wenhui; Loke, Weng Keong
2014-08-01
Ricin is a toxin that can be easily extracted from seeds of Ricinus communis plants. Ricin is considered to be a major bio-threat as it can be freely and easily acquired in large quantities. A deliberate release of such toxin in civilian populations would very likely overwhelm existing public health systems, resulting in public fear and social unrest. There is currently no commercially available or FDA-approved prophylaxis such as vaccines, or therapeutic antitoxins or antidotes, available for ricin intoxication. Patient treatment is typically supportive care based on symptoms, often designed to reinforce the body's natural response. This paper describes the development and validation of a robust ELISA test kit, which can be used to screen for ricin in biological specimens such as whole blood and faeces. Faecal specimens are shown in this study to have better diagnostic sensitivity and a wider diagnostic window compared to whole blood. From these results, it is concluded that faeces is the most suitable clinical specimen for diagnosis of ricin poisoning via the oral route. The ELISA test kit can also detect ricin in environmental samples. An advantage of this ELISA kit over other commercial off-the-shelf (COTS) detection kits currently on the market that are developed to screen environmental samples only is its ability to diagnose ricin poisoning from clinical specimens as well as detect ricin from environmental samples.
Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer
USDA-ARS?s Scientific Manuscript database
Background The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed...
Pahlavan, Autusa; Sharma, Girdhari M; Pereira, Marion; Williams, Kristina M
2016-10-01
Gluten from wheat, rye, and barley can trigger IgE-mediated allergy or Celiac disease in sensitive individuals. Gluten-free labeled foods are available as a safe alternative. Immunoassays such as the enzyme-linked immunosorbent assay (ELISA) are commonly used to quantify gluten in foods. However, various non-assay related factors can affect gluten quantitation. The effect of gluten-containing grain cultivars, thermal processing, and enzymatic hydrolysis on gluten quantitation by various ELISA kits was evaluated. The ELISA kits exhibited variations in gluten quantitation depending on the gluten-containing grain and their cultivars. Acceptable gluten recoveries were obtained in 200mg/kg wheat, rye, and barley-spiked corn flour thermally processed at various conditions. However, depending on the enzyme, gluten grain source, and ELISA kit used, measured gluten content was significantly reduced in corn flour spiked with 200mg/kg hydrolyzed wheat, rye, and barley flour. Thus, the gluten grain source and processing conditions should be considered for accurate gluten analysis. Published by Elsevier Ltd.
Multiplex method for initial complex testing of antibodies to blood transmitted diseases agents.
Poltavchenko, Alexander G; Nechitaylo, Oleg V; Filatov, Pavel V; Ersh, Anna V; Gureyev, Vadim N
2016-10-01
Initial screening of donors and population at high risk of infection with blood transmitted diseases involves a number of analyses using monospesific diagnostic systems, and therefore is expensive labor- and time-consuming process. The goal of this work is to construct a multiplex test enabling to carry out rapid initial complex testing at a low price. The paper describes a kit making it possible to detect simultaneously antibodies to six agents of the most significant blood transmitted diseases: HIV virus, hepatitis B and C viruses, cytomegalovirus, T. pallidum and T. gondii in blood products. The kit comprises multiplex dot-immunoassay based on plane protein arrays (immune chips) using colloidal gold conjugates and silver development. It provides an opportunity to carry out complex analysis within 70min at room temperature, and there is no need of well-qualified personnel. We compared laboratory findings of the kit with monospecific kits for ELISA produced by two Russian commercial companies. Dot-assay results correlate well with data obtained using commercial kits for ELISA. Furthermore, multiplex analysis is quicker and cheaper in comparison with ELISA and can be carried out in non-laboratory conditions. The kit for multiplex dot-immunoassay of antibodies to blood transmitted agents can significantly simplify initial complex testing. Copyright © 2016 Elsevier B.V. All rights reserved.
Suryawanshi, Rahul D; Malik, Satya Veer Singh; Jayarao, Bhushan; Chaudhari, Sandeep P; Savage, Emily; Vergis, Jess; Kurkure, Nitin V; Barbuddhe, Sukhadeo B; Rawool, Deepak B
2017-06-01
The present study for the first time evaluates the serodiagnostic efficacy of two recombinant antigens namely, listeriolysin O (rLLO) and phosphatidyl-inositol phospholipase C (rPI-PLC). Indirect ELISA with the above recombinant antigens was used on samples collected from bovines (n=106), goats (n=138) and pigs (n=92) having either a history of abortion, emaciation and/or apparently healthy animals. Isolation of Listeria was attempted from the blood samples using USDA-FSIS method. On screening of test sera by rLLO-based ELISA, antibodies against anti-listeriolysin O (ALLO) were observed in goats (22.46%), bovines (15.10%) and pigs (16.31%). As advocated, after adsorption of positive serum samples with streptolysin O (SLO), the seropositivity for ALLO was marginally reduced (p>0.05) in goats (21.73%) and bovines (10.38%), whereas, in pigs the reduction (5.43%) was significant (p<0.05). On the contrary, rPI-PLC-based ELISA revealed higher non-specific seropositivity for antilisterial antibodies in goats (45.65%), bovines (31.13%) and pigs (8.69%). Further, on comparing the seropositivity with isolation rate, of the 16 animals that were culturally-positive for L. monocytogenes, 15 showed ALLO positivity in unadsorbed as well as SLO-adsorbed sera by rLLO-based ELISA, however, rPI-PLC-based ELISA could detect seropositivity in only 5 animals. Moreover, rPI-PLC-based ELISA also showed seropositivity in those animals (7/30) that were culturally positive for other Listeria spp. In conclusion, rLLO can serve as a better antigen than rPI-PLC in ELISA for the serodiagnosis of listeriosis in animals; however, prior adsorption of test sera with SLO is required to avoid false positive results. Copyright © 2017 Elsevier B.V. All rights reserved.
Test/QA Plan for Verification of Microcystin Test Kits
Microcystin test kits are used to quantitatively measure total microcystin in recreational waters. These test kits are based on enzyme-linked immunosorbent assays (ELISA) with antibodies that bind specifically to microcystins or phosphate activity inhibition where the phosphatas...
Curry, Patricia S; Ribble, Carl; Sears, William C; Hutchins, Wendy; Orsel, Karin; Godson, Dale; Lindsay, Robbin; Dibernardo, Antonia; Kutz, Susan J
2014-04-01
We compared Nobuto filter paper (FP) whole-blood samples to serum for detecting antibodies to seven pathogens in reindeer (Rangifer tarandus tarandus). Serum and FP samples were collected from captive reindeer in 2008-2009. Sample pairs (serum and FP eluates) were assayed in duplicate at diagnostic laboratories with the use of competitive enzyme-linked immunosorbent assays (cELISAs) for Neospora caninum and West Nile virus (WNV); indirect ELISA (iELISAs) for bovine herpesvirus type 1 (BHV-1), parainfluenza virus type 3 (PI-3), and bovine respiratory syncytial virus (BRSV); and virus neutralization (VN) for bovine viral diarrhea virus (BVDV) types I and II. Assay thresholds were evidence-based values employed by each laboratory. Comparable performance to serum was defined as FP sensitivity and specificity ≥ 80%. Filter-paper specificity estimates ranged from 92% in the cELISAs for N. caninum and WNV to 98% in the iELISAs for PI-3 and BRSV. Sensitivity was >85% for five tests (most ≥ 95%) but was insufficient (71-82%) for the PI-3 and BRSV iELISAs. Lowering the threshold for FP samples in these two ELISAs raised sensitivity to ≥ 87% and reduced specificity slightly (≥ 90% in three of the four test runs). Sample size limited the precision of some performance estimates. Based on the criteria of sensitivity and specificity ≥ 80%, and using adjusted FP thresholds for PI-3 and BRSV, FP sensitivity and specificity were comparable to serum in all seven assays. A potential limitation of FP is reduced sensitivity in tests that require undiluted serum (i.e., N. caninum cELISA and BVDV VNs). Possible toxicity to the assay cell layer in VN requires investigation. Results suggested that cELISA is superior to iELISA for detecting antibodies in FP samples from reindeer and other Rangifer tarandus subspecies. Our findings expand the potential utility of FP sampling from wildlife.
Mohammadpour, Niloofar; Saki, Jasem; Rafiei, Abdollah; Khodadadi, Ali; Tavalla, Mehdi; Cheraghian, Bahman
2016-10-01
Toxoplasma gondii is one of the most common causes of latent infections in humans worldwide. Detecting anti- Toxoplasma antibodies in serum using serological tests is a common method to diagnose toxoplasmosis. In the present study, an indigenous ELISA kit was prepared using tachyzoites from the RH strain of T. gondii , and its sensitivity and specificity were compared with those of commercial kits. To produce antigens, 0.02 mL of locally isolated T. gondii RH strain parasites along with 10 9 tachyzoites were injected into the peritoneal cavities of 50 laboratory mice (BALB/C). Parasites were collected after 4 days. After filtering and washing, the concentration of protein in sonicated tachyzoites was calculated using the Lowry protein assay. The dilution of antigen, serum and alkaline phosphatase conjugate was assessed in designing an indigenous ELISA method; then ELISA was performed based on these dilutions, and its sensitivity was determined using 200 serum samples. In addition, the specificity of the assay was evaluated using 40 serum samples from patients with tuberculosis, leukemia or hydatid cyst. Indigenous ELISA was used to examine 100 serum samples containing anti- T. gondii IgG, with a sensitivity of 98% (commercial kits: 100%). Another 100 serum samples containing anti- T. gondii IgM were also tested, with a sensitivity of 99% (commercial kits: 100%). When 40 serum samples from patients with leukemia, hydatid cyst or tuberculosis were examined using anti- T. gondii IgG, the specificity was 100%, identical to commercial kits. However, the specificity of a similar test with anti- T. gondii IgM was just 28.6% for serum samples from leukemia patients, 21.4% for hydatid cyst and 16.7% for tuberculosis. We found that purified locally isolated soluble crude antigens of the RH strain of T. gondii from the peritoneal cavity of mice may be one of the most promising antigens for detection of human toxoplasmosis in routine screening.
Chen, Qixia; An, Jingna; Rao, Chenli; Wang, Tingting; Li, Dongdong; Feng, Shu; Tao, Chuanmin
2016-01-01
Syphilis is a major concern to global public health with increasing incidence. So its screening test should have sufficient sensitivity and specificity. We evaluated the performance of the Lumipulse G TP-N assay detection for syphilis screening and compared it with the InTec ELISA test kit for TP, which is widely used. Samples of several patient groups including 133 clinical and serologically characterized syphilitic sera, 175 samples containing potentially interfering agents, and 2290 unselected samples submitted for routine screening were detected by both the Lumipulse G TP-N assay and the InTec ELISA test kit for TP. Inconsistent samples were confirmed by RecomLine Treponema IgG, IgM immunoblot. Coefficient of variations of the Lumipulseo G TP-N assay at both levels were below 5% and of the InTec ELISA test kit for TP both over 5%. The sensitivity of the Lumipulse G TP-N assay and the InTec ELISA test kit for TP were 100% for all stages of syphilis. The two methods had consistent analytical specificity of 100% (95% CI: 97.21 - 100.00), while the clinical specificity was 100% (95% CI: 99.79 - 100.00) and 99.82% (95% CI: 99.51 - 99.94), respectively. Between them, Spearman's correlation coefficient was 0.455 and kappa value was 0.986. The overall sensitivity and specificity of the Lumipulse G TP-N assay was higher than the InTec ELISA test kit for TP (sensitivity: 100.0 versus 99.5, specificity: 100.0 versus 99.8). The automated Lumipulse G TP-N assay demonstrated excellent diagnostic sensitivity and specificity when evaluated as a screening test for syphilis. Thus, it can be an alternative to the treponemal screening test.
Short communication: ELISA system for screening of bovine mastitis caused by Prototheca zopfii.
Kano, Rui; Sato, Ayano; Sobukawa, Hideto; Sato, Yuko; Ito, Takaaki; Suzuki, Kazuyuki; Hasegawa, Atsuhiko; Kamata, Hiroshi
2016-08-01
Prototheca zopfii is an achlorophyllic alga that causes bovine mastitis, resulting in a reduction in milk production and the secretion of thin, watery milk with white flakes. This study evaluated the use of an ELISA system for distinguishing cows with mastitis due to P. zopfii genotype 2 from healthy cows and cows with chronic candidal mastitis. We also investigated the transitional changes of specific antibody titers in healthy cows injected with inactivated P. zopfii genotype 2 cells. The ELISA system exhibited the highest sensitivity (94%) and specificity (100%) for chronic protothecal mastitis when the positive cutoff value was set at 43.4 ELISA units. Anti-protothecal IgG titers were positive in all cows after they were inoculated with inactivated P. zopfii genotype 2 cells. These results indicated that ELISA detection of anti-protothecal IgG in serum provided specificity and sensitivity sufficient for diagnosing protothecal mastitis. Thus, an ELISA system incorporating this specific antiserum is expected to be valuable for definitive field-based diagnosis of bovine mastitis due to P. zopfii genotype 2. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Decline of maternal antibodies to small ruminant lentivirus in goat kids.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Reczyńska, Daria; Bagnicka, Emilia; Kaba, Jarosław
2018-06-06
We carried out this study to determine for how long small ruminant lentivirus (SRLV)-specific antibodies can be detected by three commercial ELISA kits in goat kids after suckling infected does in field conditions. Forty-one kids born to SRLV-seropositive asymptomatic does were blood sampled prior to colostrum consumption, and then weekly for 6 months in total. The sera were screened with three commercial ELISA kits: whole-virus ELISA (wELISA), recombinant transmembrane and capsid antigen ELISA (TM/CA-ELISA), and surface antigen ELISA (SU-ELISA). All but one kid were seronegative in all three ELISAs right after birth. At the age of 1 week all kids turned seropositive in wELISA, 39 kids (95%) in TM/CA-ELISA, and 35 kids (85%) in SU-ELISA. All seropositive kids turned seronegative in wELISA by the 15th week, and in SU-ELISA by the 19th week (median of 8 weeks in both ELISA), whereas in TM/CA-ELISA five kids (13% of 39 initially seropositive) were still seropositive at the age of 6 months (median of 11 weeks). Antibody levels at the age of 1 week proved significantly linked to the duration of maternal antibodies in all three ELISAs and could be employed to predict for how long maternal antibodies would remain detectable. © 2018 Japanese Society of Animal Science.
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-11-01
Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman's correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India.
Anitharaj, Velmurugan; Pradeep, Jothimani; Park, Sungman; Kim, Seung-Han; Kim, Young Jin; Kim, Eun-Ye; Kim, Yoon-Won
2016-01-01
Introduction Scrub Typhus (ST) is being reported from different parts of India in the recent past. However, the diagnosis and confirmation of ST cases require specific serological and molecular diagnostic tests. Both rapid and conventional ELISA tests need to be properly evaluated. Aim Evaluation of a new ST IgM Immunochromatography (ICT) test kit (InBios Scrub Typhus Detect IgM Rapid Test) and compare it with another rapid kit, conventional ELISA kit and Weil-Felix (WF) test. Materials and Methods This prospective study was carried out in Mahatma Gandhi Medical College and Research Institute, Puducherry, during November 2015 to June 2016. Clinically suspected 220 ST patients were examined by a new kit, InBios Scrub Typhus Detect IgM Rapid Test, taking the conventional InBios Scrub Typhus Detect IgM ELISA as reference. Additional comparison was made with ImmuneMed Scrub Typhus Rapid, and WF test (single OXK titers ≥1:320). Statistical analysis was performed (Chi-square, Spearman’s correlation and Kappa) using IBM SPSS Statistics 17 for Windows (SPSS Inc; Chicago, USA). Results Percentage Sensitivity, Specificity, Positive Predictive and Negative Predictive Values for InBios, ImmuneMed and WF were 99.25, 93.02, 95.68, 98.77; 94.87, 94.19, 96.21, 92.05 and 50.38, 95.51, 94.29, 56.67 respectively. A total of 134 patients were positive in reference standard InBios IgM ELISA. Conclusion This new rapid ST IgM kit validated for the first time in India, showed good sensitivity and specificity. As a Point-of-Care (PoC) test, the kit would be helpful in both urban and remote rural parts of India. PMID:28050364
Yunus, Muhammad Hafiznur; Tan Farrizam, Siti Naqiuyah; Abdul Karim, Izzati Zahidah; Noordin, Rahmah
2018-01-01
Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara- positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
Praud, Anne; Champion, Jean-Luc; Corde, Yannick; Drapeau, Antoine; Meyer, Laurence; Garin-Bastuji, Bruno
2012-07-09
Brucella ovis causes an infectious disease responsible for infertility and subsequent economic losses in sheep production. The standard serological test to detect B. ovis infection in rams is the complement fixation test (CFT), which has imperfect sensitivity and specificity in addition to technical drawbacks. Other available tests include the indirect enzyme-linked immunosorbent assays (I-ELISA) but no I-ELISA kit has been fully evaluated.The study aimed to compare an I-ELISA kit and the standard CFT. Our study was carried out on serum samples from 4599 rams from the South of France where the disease is enzootic. A Bayesian approach was used to estimate tests characteristics (diagnostic sensitivity, Se and diagnostic specificity, Sp). The tests were then studied together in order to optimise testing strategies to detect B. ovis. After optimising the cut-off values in order to avoid doubtful results without deteriorating the concordance between the results of the two tests, the I-ELISA appeared to be slightly more sensitive than CFT (Se I-ELISA=0.917 [0.822; 0.992], 95% Credibility Interval (CrI) compared to Se CFT=0.860 [0.740; 0.967], 95% CrI). However, CFT was slightly more specific than I-ELISA (Sp CFT=0.988 [0.947; 1.0], 95% CrI) compared to Sp I-ELISA =0.952 [0.901; 1.0], 95% CrI).The tests were then associated with two different interpretation schemes. The series association increased the specificity of screening and could be used for pre-movement testing in rams from uninfected flocks. The parallel association increased sequence sensitivity, thus appearing more suitable for eradicating the disease in infected flocks. The high sensitivity and acceptable specificity of this I-ELISA kit support its potential interest to avoid the limitations of CFT. The two tests could also be used together or combined with other diagnostic methods such as semen culture to improve the testing strategy. The choice of test sequence and interpretation criteria depends on the epidemiological context, screening objectives and the financial and practical constraints.
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan
2017-01-01
Background: In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Aims: Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. Settings and Design: ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. Materials and Methods: ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015– September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical Analysis: Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Results and Conclusion: Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR. PMID:28878522
Anitharaj, Velmurugan; Stephen, Selvaraj; Pradeep, Jothimani; Pooja, Pratheesh; Preethi, Sridharan
2017-01-01
In the recent past, scrub typhus (ST) has been reported from different parts of India, based on Weil-Felix/enzyme-linked immunosorbent assay (ELISA)/indirect immunofluorescence assay (IFA). Molecular tests are applied only by a few researchers. Evaluation of a new commercial real time polymerase chain reaction (PCR) kit for molecular diagnosis of ST by comparing it with the commonly used IgM ELISA is our aim. ST has been reported all over India including Puducherry and surrounding Tamil Nadu and identified as endemic for ST. This study was designed to correlate antibody detection by IgM ELISA and Orientia tsutsugamushi DNA in real time PCR. ST IgM ELISA (InBios Inc., USA) was carried out for 170 consecutive patients who presented with the symptoms of acute ST during 11 months (November, 2015- September, 2016). All 77 of these patients with IgM ELISA positivity and 49 of 93 IgM ELISA negative patients were subjected to real time PCR (Geno-Sen's ST real time PCR, Himachal Pradesh, India). Statistical analysis for clinical and laboratory results was performed using IBM SPSS Statistics 17 for Windows (SPSS Inc., Chicago, USA). Chi-square test with Yates correction (Fisher's test) was employed for a small number of samples. Among 77 suspected cases of acute ST with IgM ELISA positivity and 49 IgM negative patients, 42 and 7 were positive, respectively, for O. tsutsugamushi 56-kDa type-specific gene in real time PCR kit. Until ST IFA, the gold standard diagnostic test, is properly validated in India, diagnosis of acute ST will depend on both ELISA and quantitative PCR.
Senthilkumar, T M A; Subathra, M; Ramadass, P; Ramaswamy, V
2010-02-01
The efficacy of a recombinant leptospiral outer membrane protein LipL41 as an antigen for conducting IgG-Enzyme linked immunosorbent assay (ELISA) and latex agglutination test (LAT) for serodiagnosis of bovine leptospirosis was evaluated. The recombinant LipL41 antigen developed and used for detecting the antibodies was specific in detection of the pathogenic serovars of Leptospira, as the expression of the LipL41 antigen is restricted only to pathogenic leptospires. A total of 430 bovine serum samples were subjected to IgG-ELISA and LAT, and the sensitivity and specificity were assessed in comparison with microscopic agglutination test (MAT). The sensitivity and specificity of IgG-ELISA and LAT were 86.84% and 93.16%, and 95.42% and 98.33% respectively. Both the tests are found to be sensitive, specific and concurred with the standard MAT. The study concluded that the rLipL41 protein could be used as a potential diagnostic antigen in different assay formats for bovine leptospirosis.
Increased Sensitivity of HIV-1 p24 ELISA Using a Photochemical Signal Amplification System.
Bystryak, Simon; Santockyte, Rasa
2015-10-01
In this study we describe a photochemical signal amplification method (PSAM) for increasing of the sensitivity of enzyme-linked immunosorbent assay (ELISA) for determination of HIV-1 p24 antigen. The photochemical signal amplification method is based on an autocatalytic photochemical reaction of a horseradish peroxidase (HRP) substrate, orthophenylenediamine (OPD). To compare the performance of PSAM-boosted ELISA with a conventional colorimetric ELISA for determination of HIV-1 p24 antigen we employed a PerkinElmer HIV-1 p24 ELISA kit, using conventional ELISA alongside ELISA + PSAM. In the present study, we show that PSAM technology allows one to increase the analytical sensitivity and dynamic range of a commercial HIV-1 p24 ELISA kit, with and without immune-complex disruption, by a factor of approximately 40-fold. ELISA + PSAM is compatible with commercially available microtiter plate readers, requires only an inexpensive illumination device, and the PSAM amplification step takes no longer than 15 min. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods. This method can be used for both commercially available and in-house ELISA tests, and has the advantage of being considerably simpler and less costly than alternative signal amplification methods.
Nekouei, Omid; Durocher, Jean; Keefe, Greg
2016-07-01
This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs.
Nekouei, Omid; Durocher, Jean; Keefe, Greg
2016-01-01
This study assessed the diagnostic performance of a commercial ELISA for detecting bovine leukemia virus antibodies in bulk-tank milk samples from eastern Canada. Sensitivity and specificity of the test were estimated at 97.2% and 100%, respectively. The test was recommended as a cost-efficient tool for large-scale screening programs. PMID:27429469
Lee, Hyun Jung; Meldrum, Alexander D; Rivera, Nicholas; Ryu, Dojin
2014-10-01
Ochratoxin A (OTA), a nephrotoxic mycotoxin, naturally occurs in wide range of agricultural commodities. Typical screening of OTA involves various enzyme-linked immunosorbent assay (ELISA) methods. Pistachio (Pistacia vera L.) is a rich source of phenolic compounds that may result in a false positive due to structural similarities to OTA. The present study investigated the cross-reactivity profiles of phenolic compounds using two commercial ELISA test kits. High-performance liquid chromatography was used to confirm the concentration of OTA in the pistachio samples and compared with the results obtained from ELISA. When the degree of interaction and 50 % inhibitory concentration of phenolic compounds were determined, the cross-reactivity showed a pattern similar to that observed with the commercial ELSIA kits, although quantitatively different. In addition, the degree of interaction increased with the increasing concentration of phenolic compounds. The ELISA value had stronger correlations with the content of total phenolic compound, gallic acid, and catechin (R(2) = 0.757, 0.732, and 0.729, respectively) compared with epicatechin (R(2) = 0.590). These results suggest that phenolic compounds in pistachio skins may cross-react with the OTA antibody and lead to a false positive or to an overestimation of OTA concentration in ELISA-based tests.
Jaramillo Ortiz, José Manuel; Montenegro, Valeria Noely; de la Fournière, Sofía Ana María; Sarmiento, Néstor Fabián; Farber, Marisa Diana; Wilkowsky, Silvina Elizabeth
2018-01-01
The current method for Babesia spp. serodiagnosis based on a crude merozoite antigen is a complex and time-consuming procedure. An indirect enzyme-linked immunosorbent assay (iELISA) based on a recombinant multi-antigen of Babesia bovis (rMABbO) was developed for detection of antibodies in bovines suspected of infection with this parasite. The multi-antigen comprises gene fragments of three previously characterized B. bovis antigens: MSA-2c, RAP-1 and the Heat Shock protein 20 that are well-conserved among geographically distant strains. The cutoff value for the new rMABbo-iELISA was determined using 75 known—positive and 300 known—negative bovine sera previously tested for antibodies to B. bovis by the gold-standard ELISA which uses a merozoite lysate. A cutoff value of ≥35% was determined in these samples by receiver operator characteristic (ROC) curve analysis, showing a sensitivity of 95.9% and a specificity of 94.3%. The rMABbo-iELISA was further tested in a blind trial using an additional set of 263 field bovine sera from enzootic and tick-free regions of Argentina. Results showed a good agreement with the gold standard test with a Cohen’s kappa value of 0.76. Finally, the prevalence of bovine babesiosis in different tick enzootic regions of Argentina was analyzed where seropositivity values among 68–80% were obtained. A certain level of cross reaction was observed when samples from B. bigemina infected cattle were analyzed with the new test, which can be attributed to shared epitopes between 2 of the 3 antigens. This new rMABbo-iELISA could be considered a simpler alternative to detect anti Babesia spp. antibodies and appears to be well suited to perform epidemiological surveys at the herd level in regions where ticks are present. PMID:29360801
Jaramillo Ortiz, José Manuel; Montenegro, Valeria Noely; de la Fournière, Sofía Ana María; Sarmiento, Néstor Fabián; Farber, Marisa Diana; Wilkowsky, Silvina Elizabeth
2018-01-23
The current method for Babesia spp. serodiagnosis based on a crude merozoite antigen is a complex and time-consuming procedure. An indirect enzyme-linked immunosorbent assay (iELISA) based on a recombinant multi-antigen of Babesia bovis (rMABbO) was developed for detection of antibodies in bovines suspected of infection with this parasite. The multi-antigen comprises gene fragments of three previously characterized B. bovis antigens: MSA-2c, RAP-1 and the Heat Shock protein 20 that are well-conserved among geographically distant strains. The cutoff value for the new rMABbo-iELISA was determined using 75 known-positive and 300 known-negative bovine sera previously tested for antibodies to B. bovis by the gold-standard ELISA which uses a merozoite lysate. A cutoff value of ≥35% was determined in these samples by receiver operator characteristic (ROC) curve analysis, showing a sensitivity of 95.9% and a specificity of 94.3%. The rMABbo-iELISA was further tested in a blind trial using an additional set of 263 field bovine sera from enzootic and tick-free regions of Argentina. Results showed a good agreement with the gold standard test with a Cohen's kappa value of 0.76. Finally, the prevalence of bovine babesiosis in different tick enzootic regions of Argentina was analyzed where seropositivity values among 68-80% were obtained. A certain level of cross reaction was observed when samples from B. bigemina infected cattle were analyzed with the new test, which can be attributed to shared epitopes between 2 of the 3 antigens. This new rMABbo-iELISA could be considered a simpler alternative to detect anti Babesia spp. antibodies and appears to be well suited to perform epidemiological surveys at the herd level in regions where ticks are present.
Stephen, Selvaraj; Ambroise, Stanley; Pradeep, Jothimani; Gunasekaran, Dhandapany; Sangeetha, Balakrishnan; Sarangapani, Kengamuthu
2017-09-01
Seroprevalence of Q fever (QF) caused by Coxiella burnetii has been reported from different parts of India. Usually serological/molecular tests are employed for detection of infection. The present study was undertaken to verify the validity of three different QF phase II IgM ELISA kits for acute QF diagnosis by comparing with the gold standard indirect fluorescent antibody assay (IFA). Fifty eight serum samples collected from 42 patients (26 patients provided acute sample only and 16 both acute and convalescent samples) which were examined by all three commercial kits, were cross-checked with QF Phase II IgM IFA for confirmation. Eleven patients were positive for C. burnetii antibodies by IFA in acute and/or convalescent serum samples. Taking IFA as a reference, percentages of sensitivity, specificity, positive predictive value and negative predictive value for Virion-Serion/Vircell/NovaTec were 36.36, 61.29, 25.00, 73.08; 81.82, 35.48, 31.03, 84.62 and 100, 25.81, 32.35, 100 per cent, respectively. The three different ELISA kits exhibited poor agreement amongst them and unacceptable level of false positivity. IFA remains to be the only option for diagnosing acute QF. Discrepancy between the clinical findings and IFA/ELISA results needs confirmation by C. burnetii DNA detection in real-time polymerase chain reaction.
Stephen, Selvaraj; Ambroise, Stanley; Pradeep, Jothimani; Gunasekaran, Dhandapany; Sangeetha, Balakrishnan; Sarangapani, Kengamuthu
2017-01-01
Background & objectives: Seroprevalence of Q fever (QF) caused by Coxiella burnetii has been reported from different parts of India. Usually serological/molecular tests are employed for detection of infection. The present study was undertaken to verify the validity of three different QF phase II IgM ELISA kits for acute QF diagnosis by comparing with the gold standard indirect fluorescent antibody assay (IFA). Methods: Fifty eight serum samples collected from 42 patients (26 patients provided acute sample only and 16 both acute and convalescent samples) which were examined by all three commercial kits, were cross-checked with QF Phase II IgM IFA for confirmation. Results: Eleven patients were positive for C. burnetii antibodies by IFA in acute and/or convalescent serum samples. Taking IFA as a reference, percentages of sensitivity, specificity, positive predictive value and negative predictive value for Virion-Serion/Vircell/NovaTec were 36.36, 61.29, 25.00, 73.08; 81.82, 35.48, 31.03, 84.62 and 100, 25.81, 32.35, 100 per cent, respectively. Interpretation & conclusions: The three different ELISA kits exhibited poor agreement amongst them and unacceptable level of false positivity. IFA remains to be the only option for diagnosing acute QF. Discrepancy between the clinical findings and IFA/ELISA results needs confirmation by C. burnetii DNA detection in real-time polymerase chain reaction. PMID:29355147
Prevalence of Coxiella burnetii antibodies in Portuguese dairy cattle herds.
Pimenta, Luís; Alegria, Nuno; Anastácio, Sofia; Sidi-Boumedine, Karim; da Silva, Gabriela; Rabiço, Ângela; Simões, João
2015-01-01
Q fever is an important zoonotic disease which has been recently diagnosed, mainly in sheep and goats, in Portugal. The aim of the present study was to determine the prevalence of bovine Coxiella burnetii antibodies in dairy farms from the northwest of Portugal. Bulk tank milk samples were randomly obtained, on November 2013, from 90 dairy farms and assayed using an ELISA kit. The apparent prevalence was 61.1% (95% C.I. from 50.8 to 70.5%). The proportion of negative and intermediate (inconclusive) herds was 34.5% (25.5 to 44.7%) and 4.4% (1.7 to 10.9%), respectively. In conclusion, a high level of exposure to Coxiella burnetii was observed in Portuguese dairy cattle herds, highlighting the needs to better understand the epidemiology of Q fever in Portugal by the implementation of a monitoring program based on harmonized serologic and molecular methodologies and elucidation of the infection status of the herds.
Lee, Seung-Hun; Eo, Kyung-Yeon; Jung, Byeong Yeal; Kwak, Dongmi; Kwon, Oh-Deog
2017-12-01
Besnoitia besnoiti is an obligate intracellular parasite that is transmitted by direct contact or via mechanical transmission by flies as vectors. Besnoitiosis causes economic losses in the cattle industry and is regarded as a re-emerging disease in Europe. This study evaluated the seroprevalence of B. besnoiti in Korean cattle using a commercial ELISA kit. Among 558 serum samples, 19 (3.4%) tested seropositive for B. besnoiti. The statistically significant risk factors included age (≥ 2 years), sex (castrated males), and region (lower latitudes) (P < 0.05). The overall seroprevalence suggested a wide distribution of B. besnoiti infection in cattle reared in Korea. Thus, the practice of intensive cattle husbandry and the regionally different seroprevalence of B. besnoiti infection in cattle in Korea warrant routine monitoring and vector control to reduce economical losses due to bovine besnoitiosis in the country.
Nardini, Roberto; Autorino, Gian Luca; Issel, Charles J; Cook, R Frank; Ricci, Ida; Frontoso, Raffaele; Rosone, Francesca; Scicluna, Maria Teresa
2017-04-14
ELISAs are known to have a higher diagnostic sensitivity than the agar gel immunodiffusion (AGID) when employed for serological diagnosis of equine infectious anaemia (EIA). For this purpose, an "in-house" and five commercial ELISAs available in Italy were assessed by the National Reference Centre for EIA for their analytic specificity (Sp); precocity, defined as capability of detecting first antibodies produced during a new infection; precision based on repeatability and reproducibility, estimated from the coefficient of variation (CV); accuracy, estimated from multiple K and relative Sp and sensitivity (Se). Two serum panels, positive for non-equine retroviruses and the most frequent equine viruses, were employed to measure analytic Sp. ELISA precocity was also compared to that of one "in-house" and three commercial AGID kits, employing a panel of sera, collected weekly from horses infected with modified EIA viruses. Precision and accuracy were defined using results of a panel containing positive and negative sera examined in an inter-laboratory trial with the participation of the ten Official Laboratories. Furthermore, a questionnaire was used to assess the appropriateness of each kit for routine use. Analytic Sp was 100%, while the 75th percentile of CVs for positive sera varied from 0.4% to 12.73% for repeatability and from 1.6% to 44.87% for reproducibility. Although CV of the negative serum was constantly high, its outcome was unaltered. Relative Se ranged from 98.2% to 100%, relative Sp was constantly 100% and multiple K ranged from 0.95 to 1. Precocity differed among the assays: three kits detected 4.8% and 42.9% positive samples on 21 days post infection (dpi), all assays detected positive samples on 28 dpi, between 47.6% and 95.2%. Precocity of ELISAs was superior to that of the AGIDs except for two assays. In view of the feedback obtained from the questionnaires, all kits were considered appropriate for routine use. All ELISAs having high Se and precocity are preferable as a screening test in EIA surveillance programmes to the AGID tests examined. These two tests can be incorporated in a serial diagnostic pathway to improve the efficacy of a surveillance plan.
Borromeo, V; Berrini, A; De Grandi, F; Cremonesi, F; Fiandanese, N; Pocar, P; Secchi, C
2014-07-01
The development of a novel enzyme-linked immunosorbent assay (ELISA) for determining luteinizing hormone (LH) in bovine plasma is described. Anti-bovine LH (bLH) monoclonal antibodies (mAbs) were produced and characterized. One mAb recognizing the bLH β subunit was used for immunoaffinity purification of substantial amounts of biologically active bLH from pituitary glands. The purified bLH in combination with 2 anti-bLH β subunit mAbs was used to develop a sandwich ELISA, which satisfied all the criteria required to investigate LH secretory patterns in the bovine species. The ELISA standard curve was linear over the range 0.05 to 2.5 ng/mL, and the assay proved suitable for measuring bLH in plasma without any prior treatment of samples. Cross-reactivity and recovery tests confirmed the specificity of the method. The intra- and inter-assay coefficients of variation ranged between 3.41% and 9.40%, and 9.29% and 15.84%, respectively. The analytical specificity of the method was validated in vivo by provocative tests for LH in heifers, using the LH releasing peptide gonadotropin-releasing hormone. In conclusion, the adoption of mAbs for this ELISA for coating the wells and labeling, combined with the easy one-step production of reference bLH, ensures long-term continuity in large-scale measurements of LH in the bovine species. Copyright © 2014 Elsevier Inc. All rights reserved.
Dosunmu, Adedoyin Owolabi; Akinbami, Akinsegun Abduljaleel; Ismail, Ayobami Kamal; Olaiya, Modupe Adebimpe; Uche, Ebele Ifeyinwa; Aile, Igbinoba Kingsley
2017-01-01
Blood transfusion practice emphasises safety, efficacy and appropriate use. These require cost-effective programme management. This study focused on the cost of screening for transfusion transmissible infections (TTI). This was a 1 year (2016) analysis of screening in a hospital-based transfusion centre. The cost of screening all blood donors by ELISA was compared to the cost of serial screening starting from rapid kit, taking into account, the estimated cost of blood bags prevented from discard after ELISA screening (attributable cost). The cost of voluntary donor drive plus cost of ELISA screening was compared with the present cost of screening. A total of 5591 donors were screened for HIV, hepatitis B and C using the rapid kit, 291 donors were deferred (5.2%). A total of 5300 units were further screened by ELISA. A total of 435 blood units (8.2%) were discarded due to TTI positivity. TTI positivity rate was 12.98%. Only 2.36% were voluntary donors and among these 9.1% were TTI positive. The attributable cost of serial screening was 55,653.5 USD while that of screening by ELISA only was 55,910 USD. The attributable cost of rapid screening for only hepatitis B and then ELISA was 53,313.9 USD taking into consideration that 187 blood units would be prevented from undue discard. This analysis demonstrated that with proper donor selection, rapid screening for hepatitis B virus only before ELISA screening is more cost-effective. This will also reduce the waiting time for donors and counselling if HIV positive.
Khamehchian, S; Madani, R; Rasaee, M J; Golchinfar, F; Kargar, R
2007-06-01
A competitive enzyme-linked immunosorbent assay (C-ELISA) has been developed and standardized for the detection of antibodies to the rinderpest virus (RPV) in sera from cattle, sheep, and goats. The test is specific for rinderpest because it does not detect antibodies to peste-des-petits-ruminants virus (PPRV). The test depends on the ability of the monoclonal antibody (MAb) directed against the hemagglutinin (H) protein of RPV to compete with the binding of RPV antibodies in the positive serum to the H protein of this virus. This MAb recognized a region from amino acids 575 to 583 on the H protein of RPV that is unique to the RPV H protein and is not present on the hemagglutinin-neuraminidase protein of PPRV. Another C-ELISA (peptide C-ELISA) was set up using this specific region as an antigen. A threshold value of 64.4% inhibition was established for the RPV C-ELISA, with 90 known RPV-negative and 30 RPV-positive serum samples. Using common serum samples, a cutoff value of 43.0% inhibition for the peptide C-ELISA was established. Based on statistical analysis, the overall sensitivity and specificity of the RPV C-ELISA, relative to those of a commercial kit, were found to be 90.00% and 103.33%, respectively. However, the sensitivity and specificity of the peptide C-ELISA were found to be 180.00% and 73.33%, respectively. Although a common MAb in 2 new C-ELISA systems was used, variation in their percent inhibition, due to the use of different antigens, was observed. Taking into consideration the difference in percent inhibition of the 2 described assays and the commercial kit (50%), it was found that the RPV C-ELISA and the peptide C-ELISA are more specific and sensitive tools than the commercial kit for assessing herd immune status and for epidemiologic surveillance.
Zhao, Shuaiyang; Liu, Junlong; Zhao, Hongxi; Li, Youquan; Xie, Junren; Liu, Aihong; Hassan, Muhammad-Adeel; Yin, Hong; Guan, Guiquan; Luo, Jianxun
2017-02-01
Bovine theileriosis, a tick-borne protozoan disease caused by Theileria annulata, Theileria orientalis and Theileria sinensis, is widespread in China and is a serious economic problem for the Chinese livestock industry. In this study, recombinant major piroplasma surface proteins (MPSP) of T. annulata, T. orientalis and T. sinensis based on MPSP genes were expressed in Escherichia coli BL21(DE3). The immunogenicity and specificity of the three purified recombinant MPSP proteins were evaluated with the reference positive sera of T. annulata, T. orientalis, T. sinensis, Babesia bovis, B abesia bigemina, Babesia major, Babesia motasi, Theileria luwenshuni, Theileria uilenbergi and Anaplasma ovis using an enzyme-linked immunosorbent assay (ELISA) or western blotting. The results showed that all three of the rMPSP proteins had a strong reaction with the sera from cattle infected with T. annulata, T. orientalis and T. sinensis via western blotting but not with other piroplasma and Anaplasma species. Then, the rMPSP protein of T. sinensis was used to develop an iELISA for detecting the three Theileria species infections. The specificity and sensitivity were 95.7 and 95.5 %, respectively, with a threshold of 28.8 % of the specific mean antibody rate (AbR). Finally, 2473 field-collected bovine sera, from 42 prefectures of 17 provinces in China, were tested using the ELISA to evaluate the prevalence of bovine theileriosis, and the average positive rate was 43.6 %. The developed iELISA could be a suitable tool to detect the three bovine Theileria species, and the data also provided important information regarding the current prevalence of bovine theileriosis in China.
Kumar, Niranjan; Varghese, Anju; Solanki, J. B.
2017-01-01
Aim: The objective of the present study was to know the seroprevalence status of Fasciola gigantica infection in cattle and buffaloes using cysteine proteinase (CP) antigen in dot enzyme-linked immunosorbent assay (ELISA) format under field conditions. Materials and Methods: As per the standard protocol, the sera were collected from the blood of 112 cattle and 38 buffaloes of coastal areas of Navsari district, South Gujarat, India. The indirect ELISA was performed on the strip of nitrocellulose paper blotted with 1 µl of CP antigen, to detect F. gigantica seropositive animals. Results: The native CP of F. gigantica revealed a single visible band on 10% sodium dodecyl sulfate-polyacrylamide gel electrophoresis. There was no any noted cross-reaction between the selected antigen and sera of Gastrothylax crumenifer-infected animals in ELISA. Out of 150 screened bovines, the sera of 47 (31.33%) were found to be reactive in dot-ELISA, with a prevalence rate of 31.25% and 31.58% in cattle and buffaloes, respectively. The seropositive bovines with heavy, moderate, and light level of infection were 44.68%, 34.04%, and 21.28%, respectively (p<0.05 between heavy and light; p>0.05 between moderate and heavy or light). The share of F. gigantica seropositive and negative animals was 31% and 69%, respectively. The optical density at 450 nm of pooled sera of seropositive bovines with heavy, moderate, and light reactivity in plate-ELISA was significantly higher with field or reference negative sera. Conclusion: The CP-based dot-ELISA can be useful for field veterinarians for quick and timely isolation of the animals requiring urgent flukicide therapy. PMID:29184364
Rallabhandi, Prasad; Sharma, Girdhari M; Pereira, Marion; Williams, Kristina M
2015-02-18
Gluten proteins in wheat, rye and barley cause celiac disease, an autoimmune disorder of the small intestine, which affects approximately 1% of the world population. Gluten is comprised of prolamin and glutelin. Since avoidance of dietary gluten is the only option for celiac patients, a sensitive gluten detection and quantitation method is warranted. Most regulatory agencies have set a threshold of 20 ppm gluten in foods labeled gluten-free, based on the currently available ELISA methods. However, these methods may exhibit differences in gluten quantitation from different gluten-containing grains. In this study, prolamin and glutelin fractions were isolated from wheat, rye, barley, oats and corn. Intact and pepsin-trypsin (PT)-digested prolamin and glutelin fractions were used to assess their immunoreactivity and gluten recovery by three sandwich and two competitive ELISA kits. The Western blots revealed varied affinity of ELISA antibodies to gluten-containing grain proteins and no reactivity to oat and corn proteins. ELISA results showed considerable variation in gluten recoveries from both intact and PT-digested gluten fractions among different kits. Prolamin fractions showed higher gluten recovery compared to their respective glutelin fractions. Among prolamins, barley exhibited higher recovery compared to wheat and rye with most of the ELISA kits used. Hydrolysis resulted in reduced gluten recovery of most gluten fractions. These results suggest that the suitability of ELISA for accurate gluten quantitation is dependent upon various factors, such as grain source, antibody specificity, gluten proteins and the level of their hydrolysis in foods.
Validation of 2 commercial Neospora caninum antibody enzyme linked immunosorbent assays
Wu, John T.Y.; Dreger, Sally; Chow, Eva Y.W.; Bowlby, Evelyn E.
2002-01-01
Abstract This is a validation study of 2 commercially available enzyme linked immunosorbent assays (ELISA) for the detection of antibodies against Neospora caninum in bovine serum. The results of the reference sera (n = 30) and field sera from an infected beef herd (n = 150) were tested by both ELISAs and the results were compared statistically. When the immunoblotting results of the reference bovine sera were compared to the ELISA results, the same identity score (96.67%) and kappa values (K) (0.93) were obtained for both ELISAs. The sensitivity and specificity values for the IDEXX test were 100% and 93.33% respectively. For the Biovet test 93.33% and 100% were obtained. The corresponding positive (PV+) and negative predictive (PV−) values for the 2 assays were 93.75% and 100% (IDEXX), and 100% and 93.75% (Biovet). In the 2nd study, competitive inhibition ELISA (c-ELISA) results on bovine sera from an infected herd were compared to the 2 sets of ELISA results. The identity scores of the 2 ELISAs were 98% (IDEXX) and 97.33% (Biovet). The K values calculated were 0.96 (IDEXX) and 0.95 (Biovet). For the IDEXX test the sensitivity and specificity were 97.56% and 98.53%, whereas for the Biovet assay 95.12% and 100% were recorded, respectively. The corresponding PV+ and PV− values were 98.77% and 97.1% (IDEXX), and 100% and 94.44% (Biovet). Our validation results showed that the 2 ELISAs worked equally well and there was no statistically significant difference between the performance of the 2 tests. Both tests showed high reproducibility, repeatability and substantial agreement with results from 2 other laboratories. A quality assurance based on the requirement of the ISO/IEC 17025 standards has been adopted throughout this project for test validation procedures. PMID:12418782
Diagnostic performance of the "MESACUP anti-Skin profile TEST".
Horváth, Orsolya N; Varga, Rita; Kaneda, Makoto; Schmidt, Enno; Ruzicka, Thomas; Sárdy, Miklós
2016-01-01
The "MESACUP anti-Skin profile TEST" is a new, commercially available ELISA kit to detect circulating IgG autoantibodies against desmoglein 1, desmoglein 3, BP180, BP230, and type VII collagen, both simultaneously and more rapidly than previous assays. The aim of this study was to evaluate the diagnostic accuracy of this kit for the diagnosis of pemphigus foliaceus, pemphigus vulgaris, bullous pemphigoid and epidermolysis bullosa acquisita. Dual-centre retrospective study in which 138 patients with autoimmune blistering diseases were compared to 40 controls Using the MESACUP anti-Skin profile TEST, both sensitivities and specificities for desmoglein 1, desmoglein 3, BP180, BP230, and type VII collagen autoantibodies were similar to those obtained using previous, specific ELISA systems and 88% of the results were concordant without any significant difference. The MESACUP anti-Skin profile TEST had a similar performance to previously produced ELISA systems. The novel kit can be used for rapid diagnosis of most common autoimmune blistering diseases and is especially suitable for identifying overlapping disorders.
Parker, Christine H; Khuda, Sefat E; Pereira, Marion; Ross, Mark M; Fu, Tong-Jen; Fan, Xuebin; Wu, Yan; Williams, Kristina M; DeVries, Jonathan; Pulvermacher, Brian; Bedford, Binaifer; Zhang, Xi; Jackson, Lauren S
2015-12-16
Undeclared food allergens account for 30-40% of food recalls in the United States. Compliance with ingredient labeling regulations and the implementation of effective manufacturing allergen control plans require the use of reliable methods for allergen detection and quantitation in complex food products. The objectives of this work were to (1) produce industry-processed model foods incurred with egg, milk, and peanut allergens, (2) compare analytical method performance for allergen quantitation in thermally processed bakery products, and (3) determine the effects of thermal treatment on allergen detection. Control and allergen-incurred cereal bars and muffins were formulated in a pilot-scale industry processing facility. Quantitation of egg, milk, and peanut in incurred baked goods was compared at various processing stages using commercial enzyme-linked immunosorbent assay (ELISA) kits and a novel multi-allergen liquid chromatography (LC)-tandem mass spectrometry (MS/MS) multiple-reaction monitoring (MRM) method. Thermal processing was determined to negatively affect the recovery and quantitation of egg, milk, and peanut to different extents depending on the allergen, matrix, and analytical test method. The Morinaga ELISA and LC-MS/MS quantitative methods reported the highest recovery across all monitored allergens, whereas the ELISA Systems, Neogen BioKits, Neogen Veratox, and R-Biopharm ELISA Kits underperformed in the determination of allergen content of industry-processed bakery products.
Rodríguez-Prieto, Víctor; Kukielka, Deborah; Rivera-Arroyo, Belén; Martínez-López, Beatriz; de las Heras, Ana Isabel; Sánchez-Vizcaíno, José Manuel; Vicente, Joaquín
2016-01-14
Bovine viral diarrhea virus (BVDV) is a pestivirus that affects cattle production worldwide and that can infect other ungulates such as cervids and even wild boar (Sus scrofa). It is believed that domestic livestock can become infected through contact with wild animals, though it is known that infection can spread among wild animals in the absence of contact with livestock. Little is known about the sharing of BVDV infection between wild and domestic animals in the same habitat, which is important for designing eradication campaigns and preventing outbreaks, especially on hunting estates with high animal densities. We assessed the sharing of BVDV infections among hunted red deer, wild boar and cattle in south-central Spain. Sampled red deer (Cervus elaphus; n = 267) and wild boar (n = 52) were located on 19 hunting estates, and cattle (n = 180) were located on 18 nearby farms. We used ELISA kits for the serological screening, Taqman RT-PCR assay for the virus determination, and subsequent phylogenetic analysis for 17 RT-PCR positive sample amplicons. Fifty-two red deer (19.5%) and 82 cattle (45.6%) samples tested positive by ELISA. A high apparent prevalence (22.47%) was obtained for red deer, while only five cattle farms tested positive by RT-PCR. Conversely, no wild boar tested positive by both ELISA or RT-PCR. Eleven red deer (4.1%) tested positive by both ELISA and RT-PCR; these animals may have been sampled during the last phase of viremia, or they may represent previously exposed individuals infected by a different BVDV strain. The amplicons shared 92.7-100% identity and fell within the BVDV subgroup 1b, although nine of these (from four red deer and five cattle pools) formed a separate branch. This suggests that there might be a common BVDV infecting both cattle and red deer. Higher red deer abundance was significantly associated with greater risk that extensively raised cattle would test positive for BVDV by ELISA. Our findings suggest that BVDV is circulating between cattle and red deer populations in proximity, but further work is required to determine whether they share the same strain(s). These results suggest the potential of BVDV to serve as a surveillance marker in these shared habitats. High seroprevalence of BVDV in red deer from our study area suggests that although BVDV infection is common, animals usually survive the infection. Further research is needed to verify and investigate the role of red deer as a BVDV reservoir.
Klaus, Christine; Beer, Martin; Saier, Regine; Schubert, Harald; Bischoff, Sabine; Süss, Jochen
2011-01-01
Tick-borne encephalitis (TBE) in animals is not well understood yet. TBE virus (TBEV) serology in several host species could be valuable for epidemiological analyses in the field as well as for the detection of clinical cases. However, performance and suitability of the available test systems are not well assessed. Therefore, we evaluated two commercial TBEV-ELISA kits in a pilot study and compared them for their suitability in veterinary applications. For this purpose, we tested 163 field collected goat sera and evaluated the results by serum neutralization test (SNT) as "gold standard". Twenty-eight SNT positive sera (17.2%) were detected. The best suited ELISA kit was used for determination of a species-specific cutoff for horses, cattle, sheep, goats, pigs, mice, dogs, rabbits and monkeys with defined sera from animals without known or with improbable contact to TBEV. The level of non-specific ELISA results does not only differ between animal species but may also be influenced by the age of the tested animals. The number of sera which tested false positive by ELISA was higher in older than in young sheep. In order to obtain defined polyclonal sera as references, two dogs, cattle, goats, sheep, rabbits and pigs each, as well as one horse and 90 mice were immunized four times with a commercially available TBEV vaccine. In conclusion, our results demonstrated that commercial TBEV-ELISA kits are suitable for application in veterinary medicine for both, verification of clinical TBE cases and epidemiological screening. However, positive ELISA results should be verified by SNT. Only a very low number of false negative ELISA-results were found.
The Environmental Technology Verification (ETV) Program, beginning as an initiative of the U.S. Environmental Protection Agency (EPA) in 1995, verifies the performance of commercially available, innovative technologies that can be used to measure environmental quality. The ETV ...
Specific detection and quantitation of bovine IgG in bioreactor derived mouse mAb preparations.
Gall-Debreceni, Anna; Lazar, Jozsef; Kadas, Janos; Balogh, Attila; Ferenczi, Annamaria; Sos, Endre; Takacs, Laszlo; Kurucz, Istvan
2016-11-01
Monoclonal antibody and recombinant protein production benefits greatly from bovine serum as an additive. The caveat is that bovine serum IgG, co-purifies with mAbs and IgG Fc-containing fusion proteins and it presents a contaminant in the end products. In order to analytically validate the products, species specific reagents are needed that react with bovine IgG exclusively. Our attempts to find such commercially available reagents failed. Here, we report the production of species specific mAbs which recognize bovine IgG even in the presence of excess amount of mouse IgG. We present five mAbs: Bsi4028, Bsi4032, Bsi4033, Bsi4034 and Bsi4035 suitable to determine the presence of bovine IgG contamination via ELISA or immunoblotting in bioreactor derived mouse mAb preparations. To quantitate bovine IgG content we developed sensitive sandwich ELISAs capable to detect bovine IgG contaminant in the ng/ml (~10 -11 M/l) range. Finally, we show that bovine IgG is efficiently removed from bioreactor produced mouse mAb preparation via affinity depletion columns prepared with Bsi4028, Bsi4032, Bsi4033, Bsi4034, Bsi4035 mAbs. Copyright © 2016. Published by Elsevier B.V.
Greibe, Eva; Nexo, Ebba
2011-11-01
Active vitamin B12 absorption is followed by an increase in holotranscobalamin (holoTC) upon loading with a high physiological dose of the vitamin (the CobaSorb test). This study evaluates the use of a newly launched EIA kit for measurement of holoTC (active B12) in relation to the CobaSorb test. Intra-assay imprecision and linearity of the EIA kit was examined, employing serum pools of increasing holoTC concentrations. For the CobaSorb test, holoTC was measured before and after loading with 3-times 9 μg of vitamin B12 employing both the in-house ELISA and the EIA kit (n=25). The EIA kit showed an intra-assay CV between 2.2% and 5.8% for holoTC values ranging from 21 to 80 pmol/L. Employing diluted serum samples resulted in spurious high values of holoTC. The EIA kit performed well in relation to the CobaSorb test and classified the patients studied as capable of absorbing vitamin B12 (n=10) or not (n=15), as did the in-house ELISA. The Active B12 (holoTC) EIA kit proved suitable for use with the CobaSorb test, but not for analysis of diluted serum samples.
Thongdee, Pimwan; Chaijaroenkul, Wanna; Kuesap, Jiraporn; Na-Bangchang, Kesara
2014-08-01
Microscopy is considered as the gold standard for malaria diagnosis although its wide application is limited by the requirement of highly experienced microscopists. PCR and serological tests provide efficient diagnostic performance and have been applied for malaria diagnosis and research. The aim of this study was to investigate the diagnostic performance of nested PCR and a recently developed an ELISA-based new rapid diagnosis test (RDT), NovaLisa test kit, for diagnosis of malaria infection, using microscopic method as the gold standard. The performance of nested-PCR as a malaria diagnostic tool is excellent with respect to its high accuracy, sensitivity, specificity, and ability to discriminate Plasmodium species. The sensitivity and specificity of nested-PCR compared with the microscopic method for detection of Plasmodium falciparum, Plasmodium vivax, and P. falciparum/P. vivax mixed infection were 71.4 vs 100%, 100 vs 98.7%, and 100 vs 95.0%, respectively. The sensitivity and specificity of the ELISA-based NovaLisa test kit compared with the microscopic method for detection of Plasmodium genus were 89.0 vs 91.6%, respectively. NovaLisa test kit provided comparable diagnostic performance. Its relatively low cost, simplicity, and rapidity enables large scale field application.
Karen, Aly; Sousa, Noelita Melo De; Beckers, Jean-François; Bajcsy, Árpád Csaba; Tibold, János; Mádl, István; Szenci, Ottó
2015-08-01
The present study aimed to compare the accuracy of a commercial PAG-ELISA test (Bovine Preg Test 29) and bovine pregnancy-associated glycoprotein radioimmunoassay (PAG-RIA) for diagnosing pregnancy at Day 28 after insemination in dairy cows. Transrectal ultrasonography (TRUS) was performed in 100 Holstein-Friesian cows at Day 28 after artificial insemination (AI; Day 0) to diagnose pregnancy. After TRUS examination, blood sample was collected from the coccygeal vessels of each cow to measure the concentrations of bPAGs by PAG-RIA test and Bovine Preg Test 29. Milk samples were collected at Days 0, 21 and 28 for measurement of progesterone (P4) by ELISA test. The cows were re-examined by TRUS at Day 42 to confirm the pregnancy diagnoses. The actual gold standard was based on TRUS outcomes at Day 28 that agreed with the outcomes of PAG-RIA test or PAG-ELISA test. If the outcomes of TRUS at Day 28 and PAG-RIA test and PAG-ELISA test did not agree, the gold standard was based on the outcome of TRUS at Day 42. Out of 100 inseminated cows, 41 were confirmed pregnant at Day 28 after AI. Based on the actual gold standard, the sensitivity of TRUS, PAG-ELISA and PAG-RIA tests for diagnosing pregnant cows at Day 28 were 92.7%, 90.2% and 100%, while the specificity of the three tests for diagnosing non-pregnant cows were 91.5%, 98.3% and 94.4%, respectively. The overall accuracy of the three tests were 92%, 95% and 97%, respectively. The degree of agreement (Kappa±S.E.) between PAG-RIA and PAG-ELISA test was 0.90 ±0.04. The degrees of agreement between PAG-RIA and PAG-ELISA and TRUS at Day 28 were 0.80±0.05 and 0.76±0.06, respectively. In conclusion, the commercial PAG-ELISA test is a highly accurate method for diagnosing early pregnancy in dairy cows on Day 28 after AI and may be used as an alternative method to the TRUS and the PAG-RIA test. Copyright © 2015 Elsevier B.V. All rights reserved.
Marcondes, Mary; de Lima, Valéria Marçal Félix; de Araújo, Maria de Fátima Lereno; Hiramoto, Roberto Mitsuyoshi; Tolezano, José Eduardo; Vieira, Rafael F C; Biondo, Alexander W
2013-11-08
Development of vaccines against canine visceral leishmaniasis (CVL) may provide a prophylactic barrier, but antibody response detected by standard diagnostic techniques may not separate vaccinated from naturally infected dogs. Moreover, anti-Leishmania antibody levels in vaccinated dogs may be detectable for months. Accordingly, the aim of the present study was to comparatively evaluate an "in-house" ELISA with three serological tests officially adopted by the Brazilian Ministry of Health for the diagnosis of CVL in dogs vaccinated with Leishmune(®). A total of 18 mongrel dogs were submitted to a complete protocol of the vaccine, monitored and evaluated in 5 times (T0-T4) up to 180 days after T0. Twenty-one days after the first dose (T1), 50% of the dogs were seropositive by the "in-house" ELISA and 5.5% by IFAT, while by the official ELISA and DPP(®) CVL rapid test all dogs tested negative. At time T2, 42 days after of the first dose, 100%, 83.3%, 11.1%, and 5.5% of the dogs were seropositive by the "in-house" ELISA, IFAT, official ELISA kit and the DPP(®) CVL rapid test, respectively. Ninety days after the first dose (T3), 100%, 83.3%, 72.2% and 33.3% of the dogs were seropositive by the "in-house" ELISA, official ELISA kit, IFAT, and the DPP(®) CVL rapid test, respectively. Finally, at time T4, 88.8%, 33.3%, 11.1% and 5.5% of the dogs were seropositive by the "in-house" ELISA, official ELISA kit, DPP(®) CVL rapid test and IFAT, respectively. In conclusion, dogs vaccinated with Leishmune(®) cross-react by an "in-house" ELISA and by the three official Brazilian serological tests for the diagnosis of canine visceral leishmaniasis up to six months after the first vaccine dose, and may be mistakenly diagnosed and removed. Copyright © 2013 Elsevier B.V. All rights reserved.
Murata, Takashi; Tsuzaki, Kokoro; Nirengi, Shinsuke; Watanabe, Tomokazu; Mizutani, Yukako; Okada, Hayami; Tsukamoto, Masami; Odori, Shinji; Nakagawachi, Reiko; Kawaguchi, Yaeko; Yoshioka, Fumi; Yamada, Kazunori; Shimatsu, Akira; Kotani, Kazuhiko; Satoh-Asahara, Noriko; Sakane, Naoki
2017-07-01
The distributer of the anti-glutamic acid decarboxylase antibody assay kit using radioimmunoassay (RIA) recently announced its discontinuation, and proposed an alternative kit using enzyme-linked immunosorbent assay (ELISA). The aim of the present study was to investigate the diagnostic values of the anti-glutamic acid decarboxylase antibody by RIA and ELISA among type 1 diabetes mellitus patients and control participants. A total of 79 type 1 diabetes mellitus patients and 79 age-matched controls were enrolled and assessed using RIA and ELISA. Sensitivity, specificity, positive predictive values and negative predictive values were calculated for cut-off values (RIA = 1.5 U/mL and ELISA = 5.0 U/mL, respectively). Kappa coefficients were used to test for agreements between the RIA and ELISA methods regarding the diagnosis of type 1 diabetes mellitus. The sensitivity, specificity, positive predictive values, and negative predictive values for diagnosing type 1 diabetes mellitus were 57.0, 97.5, 95.7, and 69.4% by RIA, and 60.8, 100.0, 100.0 and 71.8% by ELISA, respectively. The diagnosis of type 1 diabetes mellitus using the RIA and ELISA methods showed substantial agreement with the kappa values of 0.74 for all participants, and of 0.64 for the acute type; however, there was moderate agreement with the kappa value of 0.56 for the slowly progressive type. The present study suggests that both anti-glutamic acid decarboxylase antibody by RIA and ELISA was useful for diagnosing type 1 diabetes mellitus. However, in the slowly progressive type, the degree of agreement of these two kits was poorer compared with those in all participants or in the acute type. © 2016 The Authors. Journal of Diabetes Investigation published by Asian Association for the Study of Diabetes (AASD) and John Wiley & Sons Australia, Ltd.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-08
... analytical method using enzyme- linked immunosorbent assay (ELISA) analyses for the qualitative detection of... study conducted by an independent third party laboratory to evaluate the ELISA test kit's performance as...
Menzies, Sandra L.; Kadwad, Vijay; Pawloski, Lucia C.; Lin, Tsai-Lien; Baughman, Andrew L.; Martin, Monte; Tondella, Maria Lucia C.; Meade, Bruce D.
2009-01-01
Adequately sensitive and specific methods to diagnose pertussis in adolescents and adults are not widely available. Currently, no Food and Drug Administration-approved diagnostic assays are available for the serodiagnosis of Bordetella pertussis. Since concentrations of B. pertussis-specific antibodies tend to be high during the later phases of disease, a simple, rapid, easily transferable serodiagnostic test was developed. This article describes test development, initial evaluation of a prototype kit enzyme-linked immunosorbent assay (ELISA) in an interlaboratory collaborative study, and analytical validation. The data presented here demonstrate that the kit met all prespecified criteria for precision, linearity, and accuracy for samples with anti-pertussis toxin (PT) immunoglobulin G (IgG) antibody concentrations in the range of 50 to 150 ELISA units (EU)/ml, the range believed to be most relevant for serodiagnosis. The assay met the precision and linearity criteria for a wider range, namely, from 50 to 200 EU/ml; however, the accuracy criterion was not met at 200 EU/ml. When the newly adopted World Health Organization International Standard for pertussis antiserum (human) reference reagent was used to evaluate accuracy, the accuracy criteria were met from 50 to 200 international units/ml. In conclusion, the IgG anti-PT ELISA met all assay validation parameters within the range considered most relevant for serodiagnosis. This ELISA was developed and analytically validated as a user-friendly kit that can be used in both qualitative and quantitative formats. The technology for producing the kit is transferable to public health laboratories. PMID:19864485
Korshun, Ludmila; Vudmaska, Mariya; Moysa, Larissa; Kovtonjuk, Galina; Mikhalap, Svetlana; Ganova, Larissa; Spivak, Nikolay
2013-12-01
In order to the detection of type-specific IgG to herpes simplex virus type 2 (HSV-2) in human serum or plasma the recombinant analog of HSV-2 glycoprotein G (gG2) was created. To construct an expression vector the DNA fragment with a sequence identical to immunodominant regions of HSV-2 gG2 was cloned into modified vector pET28a containing of the glutation-S-transferase sequence (pET28-GST). Escherichia coli BL21 (DE3) were transformed with the recombinant plasmid. The target protein was expressed mainly in soluble form. Chromatographic purification of soluble GST-gG2 protein was performed taking into account the features of its primary structure that are 6His-tag and GST-tag. To determine the affinity constant of the specific IgG to GST-gG2 we used the method proposed by Friguet et al. (1985). The affinity constants were within the range of 10(7)-10(8)M(-1) proving their high-affinity. The purified recombinant HSV-2 antigen was used to design a diagnostic ELISA kit, which was evaluated with referent controls and standard panels of sera containing and/or not containing anti-HSV-2 IgG. Comparative evaluation of this kit and the commercially available "HSV-Type 2 IgG-ELISA" (NovaTec, Dietzenbach, Germany) kit was performed. There was no significant difference (P>0.05). It allows to use developed ELISA kit for clinical diagnosis of HSV-2 infection. Copyright © 2013 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
Bovine viral diarrhea virus (BVDV) infections, whether as acute, persistent or contributing to co-infections, result in significant losses for cattle producers. BVDV can be identified by real-time PCR and ELISA, detection and quantification of viral infection at the single cell level is extremely di...
USDA-ARS?s Scientific Manuscript database
Bovine viral diarrhea virus (BVDV) infections, whether as acute, persistent or contributing to co-infections, result in significant losses for cattle producers. BVDV can be identified by real-time PCR and ELISA, detection and quantification of viral infection at the single cell level is extremely di...
Thür, B; Caplazi, P; Hilbe, M; Zlinszky, K; Strasser, M; Corboz, L; Ehrensperger, F
1998-04-01
The causal involvement of bovine viral diarrhoea virus (BVDV) and border disease virus (BDV) infection in bovine and ovine abortion and perinatal mortality remain unclear. From 1992 until 1994, 213 bovine and 31 ovine foetuses as well as 36 calves and 25 lambs which had died perinatally were investigated. Tissue samples were tested for the presence of pestiviruses and serum or fluid from the body cavities were analysed for the presence of pestivirus antibodies. Detection of pestiviruses was performed by (i) cell culture isolation, (ii) antigen ELISA and (iii) immunohistochemical staining for viral antigen. For antibody-testing an indirect ELISA was used. In nine bovine foetuses and in two calves BVDV was isolated. Pestiviruses, most likely BDV were detected in one ovine foetus and three lambs. In 6% of the bovine and 11% of the ovine foetuses anti-pestivirus antibodies were detected. However, clinical features and history of bovine cases did not show a correlation with the diagnostic results, In contrast, the presence of central nervous system signs in neonatal lambs and the detection of BDV was correlated.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-16
...-Mouth Disease 3ABC ELISA Diagnostic Kit AGENCY: Science and Technology Directorate, Plum Island Animal... Center (PIADC), is seeking industry collaborators to aid DHS S&T in developing an ELISA diagnostic test... and Mouth Disease virus (FMDV) non-structural proteins (NSP): 3A, 3B, or 3C. This new FMDV 3ABC ELISA...
Evaluation of Commercially Available Anti–Dengue Virus Immunoglobulin M Tests
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala D.; Enria, Delia A.; Pelegrino, Jose L.; Vázquez, Susana; Artsob, Harvey; Drebot, Michael; Gubler, Duane J.; Halstead, Scott B.; Guzmán, María G.; Margolis, Harold S.; Nathanson, Carl-Michael; Lic, Nidia R. Rizzo; Bessoff, Kovi E.; Kliks, Srisakul
2009-01-01
Anti–dengue virus immunoglobulin M kits were evaluated. Test sensitivities were 21%–99% and specificities were 77%–98% compared with reference ELISAs. False-positive results were found for patients with malaria or past dengue infections. Three ELISAs showing strong agreement with reference ELISAs will be included in the World Health Organization Bulk Procurement Scheme. PMID:19239758
Toftaker, Ingrid; Toft, Nils; Stokstad, Maria; Sølverød, Liv; Harkiss, Gordon; Watt, Neil; O' Brien, Amanda; Nødtvedt, Ane
2018-06-01
Bovine respiratory syncytial virus (BRSV) and bovine coronavirus (BCV) are responsible for respiratory disease and diarrhea in cattle worldwide. The Norwegian control program against these infections is based on herd-level diagnosis using a new multiplex immunoassay. The objective of this study was to estimate sensitivity and specificity across different cut-off values for the MVD-Enferplex BCV/BRSV multiplex, by comparing them to a commercially available ELISA, the SVANOVIR ® BCV-Ab and SVANOVIR ® BRSV-Ab, respectively. We analyzed bulk tank milk samples from 360 herds in a low- and 360 herds in a high-prevalence area. As none of the tests were considered perfect, estimation of test characteristics was performed using Bayesian latent class models. At the manufacturers' recommended cut-off values, the median sensitivity for the BRSV multiplex and the BRSV ELISA was 94.4 [89.8-98.7 95% Posterior Credibility Interval (PCI)] and 99.8 [98.7-100 95% PCI], respectively. The median specificity for the BRSV multiplex was 90.6 [85.5-94.4 95% PCI], but only 57.4 [50.5-64.4 95% PCI] for the BRSV ELISA. However, increasing the cut-off of the BRSV ELISA increased specificity without compromising sensitivity. For the BCV multiplex we found that by using only one of the three antigens included in the test, the specificity increased, without concurrent loss in sensitivity. At the recommended cut-off this resulted in a sensitivity of 99.9 [99.3-100 95% PCI] and specificity of 93.7 [88.8-97.8 95% PCI] for the multiplex and a sensitivity of 99.5 [98.1-100 95% PCI] and a specificity of 99.6 [97.6-100 95% PCI] for the BCV ELISA. Copyright © 2018 Elsevier B.V. All rights reserved.
Alvarez-García, Gema; García-Culebras, Alicia; Gutiérrez-Expósito, Daniel; Navarro-Lozano, Vanesa; Pastor-Fernández, Iván; Ortega-Mora, Luis Miguel
2013-11-15
Bovine neosporosis control programs are currently based on herd management and serodiagnosis because effective treatments and vaccines are unavailable. Although a wide variety of serological tools have been developed, enzyme-linked immunosorbent assays (ELISAs) are the most commonly commercialized tests. Partial comparative studies have been performed in the past, and the panel of available ELISAs has notably changed in the last few years. Therefore, diagnostic laboratories are requesting updated information about the performance of these tests. Accordingly, the aim of this study was to compare all of the commercially available ELISAs (n=10) by evaluating their performance and to re-standardize them based on TG-ROC analyses when necessary. For this purpose, a well-characterized serum panel from experimentally and naturally infected bovines and non-infected bovines (n=458) was used. Two different definitions of gold standard were considered: (i) the result of the majority of tests and (ii) pre-test information based on epidemiological, clinical and serological data. Most of the tests displayed high sensitivity (Se) and specificity (Sp) values when both gold standard criteria were considered. Furthermore, all the tests showed near perfect agreement, with the exception of the pair-wise comparisons that included the VMRD and SVANOVIR. The best-adjusted ELISAs were the HIPRA-CIVTEST, IDVET, BIOVET and IDEXX Rum (Se and Sp>95%). After the TG-ROC analyses, higher Se and Sp values were obtained for the BIO-X, LSI Bov, LSI Rum and IDEXX Bov, though the increases were more significant for the SVANOVIR and VMRD. The Kappa values also increased with the new adjusted cut-offs. This is the first study that offers updated performance evaluations of commercially available ELISAs. Such analyses are essential for diagnostic laboratories and are valuable to the companies that develop and distribute these tests. Copyright © 2013 Elsevier B.V. All rights reserved.
[Real-time PCR kits for the detection of the African Swine Fever virus].
Latyshev, O E; Eliseeva, O V; Grebennikova, T V; Verkhovskiĭ, O A; Tsibezov, V V; Chernykh, O Iu; Dzhailidi, G A; Aliper, T I
2014-01-01
The results obtained using the diagnostic kit based on real-time polymerase chain reaction to detect the DNA of the African Swine Fever in the pathological material, as well as in the culture fluid, are presented. A high sensitivity and specificity for detection of the DNA in the organs and tissues of animals was shown to be useful for detection in the European Union referentiality reagent kits for DNA detection by real time PCR of ASFV. More rapid and effective method of DNA extraction using columns mini spin Quick gDNA(TM) MiniPrep was suggested and compared to the method of DNA isolation on the inorganic sorbent. High correlation of the results of the DNA detection of ASFV by real-time PCR and antigen detection results ASFV by competitive ELISA obtained with the ELISA SEROTEST/INGEZIM COMRAC PPA was demonstrated. The kit can be used in the veterinary services for effective monitoring of ASFV to contain, eliminate and prevent further spread of the disease.
Wang, Tao; Zhang, Caixia; Cao, Xiuqin; Yang, Zhiwei
2013-12-01
To express and purify the recombinant major outer membrane protein (MOMP) of Legionella pneumophila (Lp) as diagnostic antigen, and explore its practical value in the serological diagnosis of Lp infection. The recombinant plasmid pET-momp was transformed into the E.coli BL21 competent cells. The recombinant MOMP was induced to express, and then analyzed by SDS-PAGE electrophoresis, purified by affinity chromatography. We screened and obtained 58 positive blood serum and 32 negative blood serum using the DRG (Germany, IgG/IgM/IgA) Lp kit. The blood serum samples were detected for IgG, IgM, IgA antibody levels by indirect ELISA that we had established with the purified MOMP as the coating antigen, as well as by R&D (USA, IgG/IgM/IgA) Lp kit. Then using the receiver operating characteristic (ROC) curve, we compared these two methods in the sensitivity, specificity and consistency of the test results, for evaluating the application value of the indirect ELISA of recombinant MOMP. The approximately 45 000 recombinant MOMP was successfully expressed and purified. Compared with the indirect ELISA we established with the R&D Lp kit for detecting Lp antibody IgG, IgM and IgA in blood serum, the sensitivity of the indirect ELISA of recombinant MOMP to IgG was 90.9%, the specificity was 91.7%, the Kappa value was 0.784 (P < 0.05), and the area under the ROC curve was 0.913; the sensitivity to IgM was 91.4% and the specificity was 90.6%, the Kappa value was 0.809 (P < 0.05), and the area under the ROC curve was 0.910; the sensitivity to IgA was 92.1% and the specificity was 88.9%, the Kappa value was 0.793(P < 0.05), and the area under the ROC curve was 0.905. The recombinant MOMP was successfully induced to express and purified. The indirect ELISA we established with the recombinant MOMP protein as a diagnostic antigen showed good specificity, sensitivity and consistency, which laid a foundation for the development of serological diagnosis kit of Legionnaires' disease.
Xu, Jian; Wu, Jing; Jiang, Bo; He, Houjun; Zhang, Xixi; Li, Xiaoyang; Yang, Dawei; Huang, Xiufen; Sealy, Joshua E; Iqbal, Munir; Li, Yongqing
2017-12-01
Glycoprotein D (gD) of bovine herpesvirus-1 (BoHV-1) is essential for attachment and penetration of cells during infection and is a major target for neutralizing antibodies during an adaptive immune response. Currently there are no recombinant antibodies capable of binding gD epitopes for use in treating BoHV-1 infection. In this study, a bovine scFv gene derived from a hybridoma secreting monoclonal antibodies (McAbs) against the amino acid motif MEESKGYEPP of gD was expressed in E. coli. Molecular modeling, western blot and ELISA analysis showed that this scFv had a high affinity for BoHV-1 gD, with a Kd of 161.2 ± 37.58 nM and for whole BoHV-1 virus, with a Kd of 67.44 ± 16.99 nM. In addition, this scFv displayed a high affinity for BoHV-1 antigen in an ELISA and competed with BoHV-1 anti-serum in a competitive ELISA. Immunofluorescence assay (IFA) and laser confocal microscopy showed that this scFv could efficiently bind to and be internalized by BoHV-1 infected Madin-Darby bovine kidney (MDBK) cells. Importantly, this scFv was shown to inhibit BoHV-1 infectivity and to reduce the number of viral plaques by blocking viral attachment to MDBK cells. Our study suggests that this bovine single-chain antibody could be developed for use as a diagnostic and therapeutic agent against BoHV-1 infection in cattle.
Watanabe, Eiki; Miyake, Shiro
2013-01-15
This work presents analytical performance of a kit-based direct competitive enzyme-linked immunosorbent assay (dc-ELISA) for azoxystrobin detection in agricultural products. The dc-ELISA was sufficiently sensitive for analysis of residue levels close to the maximum residue limits. The dc-ELISA did not show cross-reactivity to other strobilurin analogues. Absorbance decreased with the increase of methanol concentration in sample solution from 2% to 40%, while the standard curve became most linear when the sample solution contained 10% methanol. Agricultural samples were extracted with methanol, and the extracts were diluted with water to 10% methanol adequate. No significant matrix interference was observed. Satisfying recovery was found for all of spiked samples and the results were well agreed with the analysis with liquid chromatography. These results clearly indicate that the kit-based dc-ELISA is suitable for the rapid, simple, quantitative and reliable determination of the fungicide. Copyright © 2012 Elsevier Ltd. All rights reserved.
Pancreatic Reference Set Application- Ann Killary-MD Anderson (2012) — EDRN Public Portal
ELISA assays. We propose to screen a two gene panel (TNC/TFPI) from functional genomic pathways approaches, by ELISA assays, in a collection of blinded plasma samples with the PCCG. In subsequent years, we will add to this panel additional candidates identified in the parent EDRN grant that are in the migration signature network or the 20q amplicon. For ELISA assays, we will utilize commercially available kits. Plasma levels of the predominant isoform of TNC, TNC-large variant (TNC-L) will be determined using a Human Tenascin-C Large (HMV) (FNIII-B) ELISA kit (IBL-America, Minneapolis, MN), which detects human TNC high molecular weight variant by sandwich ELISA. Plasma TFPI levels will be determined using a commercially available Quantikine Human TFPI ELISA kit (DTFP10) (R&D; Systems, Inc. Minneapolis, MN), which detects predominantly free TFPI and a very small percentage of LDL and HDL-bound TFPI by sandwich ELISA. Additional ELISA assays will be added in years 2-3 using ingenuity network analysis to identify secreted proteins that interact with migration signature proteins identified using functional genomic approaches. In addition, Dr. Sen’s lab has identified candidate biomarkers mapping with the 20q amplicon and which are both amplified and overexpressed as well as are secreted proteins. In years 2-3, we will examine all candidate markers by ELISA to determine 20q pathway markers increase the sensitivity and specificity of the 3p panel. Validation of a 4 miR Panel. For assaying the levels of miRs in plasma, qRT-PCR assays will be performed, as described (9). For the selected panel of miRs, we propose to develop a high throughput qRT-PCR assay by adapting our published method to a 96 well format where the critical steps of purification, such as LiCl precipitation and DNAse treatments will be done in successive steps in the same plates. In years 2-3, additional miRs that target both the 20q amplicon genes as well as miRs that target migration genes in Dr. Killary’
Park, Douglas L; Coates, Scott; Brewer, Vickery A; Garber, Eric A E; Abouzied, Mohamed; Johnson, Kurt; Ritter, Bruce; McKenzie, Deborah
2005-01-01
Performance Tested Method multiple laboratory validations for the detection of peanut protein in 4 different food matrixes were conducted under the auspices of the AOAC Research Institute. In this blind study, 3 commercially available ELISA test kits were validated: Neogen Veratox for Peanut, R-Biopharm RIDASCREEN FAST Peanut, and Tepnel BioKits for Peanut Assay. The food matrixes used were breakfast cereal, cookies, ice cream, and milk chocolate spiked at 0 and 5 ppm peanut. Analyses of the samples were conducted by laboratories representing industry and international and U.S governmental agencies. All 3 commercial test kits successfully identified spiked and peanut-free samples. The validation study required 60 analyses on test samples at the target level 5 microg peanut/g food and 60 analyses at a peanut-free level, which was designed to ensure that the lower 95% confidence limit for the sensitivity and specificity would not be <90%. The probability that a test sample contains an allergen given a prevalence rate of 5% and a positive test result using a single test kit analysis with 95% sensitivity and 95% specificity, which was demonstrated for these test kits, would be 50%. When 2 test kits are run simultaneously on all samples, the probability becomes 95%. It is therefore recommended that all field samples be analyzed with at least 2 of the validated kits.
Wei, Kai; Zhang, Haiyan; Zhang, Yuewei; Xu, Jian; Jiang, Fei; Liu, Xu; Xu, Wei; Wu, Wenxue
2014-01-01
The pathogen Mycoplasma bovis (M. bovis) is a major cause of respiratory disease, mastitis, and arthritis in cattle. Screening the key immunogenic proteins and updating rapid diagnostic techniques are necessary to the prevention and control of M. bovis infection. In this study, 19 highly immunogenic proteins from M. bovis strain PD were identified using 2-dimensional gel electrophoresis, immunoblotting and MALDI-TOF/TOF MS. Of these 19 proteins, pyruvate dehydrogenase E1 component beta subunit (PDHB) showed excellent immune reactivity and repeatability. PDHB was found to be conserved in different M. bovis isolates, as indicated by Western blot analysis. On the basis of these results, a rPDHB-based indirect ELISA (iELISA) was established for the detection of serum antibodies using prokaryotically expressed recombinant PDHB protein as the coating antigen. The specificity analysis result showed that rPDHB-based iELISA did not react with other pathogens assessed in our study except M. agalactiae (which infects sheep and goats). Moreover, 358 serum samples from several disease-affected cattle feedlots were tested using this iELISA system and a commercial kit, which gave positive rates of 50.8% and 39.9%, respectively. The estimated Kappa agreement coefficient between the two methods was 0.783. Notably, 39 positive serum samples that had been missed by the commercial kit were all found to be positive by Western blot analysis. The detection rate of rPDHB-based iELISA was significantly higher than that of the commercial kit at a serum dilution ratio of 1∶5120 to 1∶10,240 (P<0.05). Taken together, these results provide important information regarding the novel immunogenic proteins of M. bovis. The established rPDHB-based iELISA may be suitable for use as a new method of antibody detection in M. bovis. PMID:24520369
Litster, A L; Pressler, B; Volpe, A; Dubovi, E
2012-08-01
Canine parvovirus (CPV) and canine distemper virus (CDV) are highly infectious and often fatal diseases with worldwide distributions, and are important population management considerations in animal shelters. A point-of-care ELISA test kit is available to detect serum antibodies to CPV and CDV, and presumptively to predict protective status. The aim of this study was to determine the diagnostic accuracy of the test compared to CPV hemagglutination inhibition titers and CDV serum neutralization titers determined by a reference laboratory, using sera collected from dogs housed at animal shelters. The ELISA test was used under both field and laboratory conditions and duplicate specimens were processed using an extra wash step. The test kit yielded accurate results (CPV: sensitivity 92.3%, specificity 93.5%; CDV: sensitivity 75.7%, specificity 91.8%) under field conditions. CDV sensitivity was improved by performing the test under laboratory conditions and using an optical density (OD) meter (laboratory performed 94.0%; OD 88.1%). Point-of-care ELISA testing for serum CPV and CDV antibody titers was demonstrated to be a useful tool for determining antibody status when making decisions regarding the need for CPV and/or CDV vaccination and also in animal shelters for population management. Copyright © 2012 Elsevier Ltd. All rights reserved.
Immunochemical analytical methods for the determination of peanut proteins in foods.
Whitaker, Thomas B; Williams, Kristina M; Trucksess, Mary W; Slate, Andrew B
2005-01-01
Peanut proteins can cause allergenic reactions that can result in respiratory and circulatory effects in the body sometimes leading to shock and death. The determination of peanut proteins in foods by analytical methods can reduce the risk of serious reactions in the highly sensitized individual by allowing for the detection of these proteins in a food at various stages of the manufacturing process. The method performance of 4 commercially available enzyme-linked immunosorbent assay (ELISA) kits was evaluated for the detection of peanut proteins in milk chocolate, ice cream, cookies, and breakfast cereals: ELISA-TEK Peanut Protein Assay, now known as "Bio-Kit" for peanut proteins, from ELISA Technologies Inc.; Veratox for Peanut Allergens from Neogen Corp.; RIDASCREEN Peanut Kit from R-Biopharm GmbH; and ProLisa from Canadian Food Technology Ltd. The 4 test kits were evaluated for accuracy (recovery) and precision using known concentrations of peanut or peanut proteins in the 4 food matrixes. Two different techniques, incurred and spiked, were used to prepare samples with 4 known concentrations of peanut protein. Defatted peanut flour was added in the incurred samples, and water-soluble peanut proteins were added in the spiked samples. The incurred levels were 0.0, 10, 20, and 100 microg whole peanut per g food; the spiked levels were 0.0, 5, 10, and 20 microg peanut protein per g food. Performance varied by test kit, protein concentration, and food matrix. The Veratox kit had the best accuracy or lowest percent difference between measured and incurred levels of 15.7% when averaged across all incurred levels and food matrixes. Recoveries associated with the Veratox kit varied from 93 to 115% for all food matrixes except cookies. Recoveries for all kits were about 50% for cookies. The analytical precision, as measured by the variance, increased with an increase in protein concentration. However, the coefficient of variation (CV) was stable across the 4 incurred protein levels and was 7.0% when averaged across the 4 food matrixes and analytical kits. The R-Biopharm test kit had the best precision or a CV of 4.2% when averaged across all incurred levels and food matrixes. Because measured protein values varied by test kit and food matrix, a method was developed to normalize or transform measured protein concentrations to an adjusted protein value that was equal to the known protein concentration. The normalization method adjusts measured protein values to equal the true protein value regardless of the type test kit or type food matrix.
Beyhan, Yunus Emre; Taş Cengiz, Zeynep
2017-08-23
Background/aim: This study included patients who had digestive system complaints between August 2015 and October 2015. The research was designed to compare conventional microscopy with an antigen detection ELISA kit and the TaqMan-based real-time PCR (RT-PCR) technique for detection of Giardia intestinalis in human stool specimens. Materials and methods: Samples were concentrated by formalin-ether sedimentation technique and microscopic examinations were carried out on wet mount slides. A commercially available ELISA kit (Giardia CELISA, Cellabs, Brookvale, Australia) was used for immunoassay. DNA was extracted from fecal samples of about 200 mg using the QIAamp Fast DNA Stool Mini Kit (QIAGEN, Hilden, Germany) and the LightCycler Nano system (Roche Diagnostics, Mannheim, Germany) was used for the TaqMan-based RT-PCR assay. Results: A total of 94 stool samples, 38 of them diagnosed positive (40.4%) and 56 of them diagnosed negative by microscopy, were selected for evaluation by antigen detection and molecular assays. The prevalence of G. intestinalis infection was found as 46.8% (n: 44) and 79.8% (n: 75) by ELISA and RT-PCR, respectively. RT-PCR revealed by far the highest positivity rate compared to the other two methods. The difference between these methods was found to be statistically significant (P < 0.05). In comparison to PCR, the sensitivity and specificity of microscopy and ELISA were 50.7% and 100% and 53.3% and 79%, respectively. Conclusion: RT-PCR seems to be much more sensitive and beneficial for rapid and accurate diagnosis of G. intestinalis in human stools.
Liu, Ying; Chen, Yu-qing; Zhou, Jing-jing; Han, Jia; Liang, Yu; Li, Xue-ying; Zhang, Hong
2012-04-18
To establish a method of enzyme-linked immunosorbent assay (ELISA) to measure urinary uromodulin and explore the urinary uromudulin level in IgA nephropathy. The rabbit anti-human uromodulin polyclonal antibodies were coated on plates to capture uromodulin and the mouse anti-human uromodulin monoclonal antibody was used as detecting antibody to set up ELISA procedure. The precision and repeatability of this ELISA method were evaluated, and then this method was compared with the commercialized Tamm-Horsfall Glycoprotein ELISA Kit by examining urinary uromodulin levels in 55 individuals. Finally, the urinary uromodulin level in 166 IgA nephropathy patients were detected as well as 48 normal controls with this established method. The detecting range of uromodulin was 0.78-12.5 μg/L by this method. The coefficient of variation within-run was 7.5%, and between-run of coefficient of variation was 7.9%. Correlation of this method and comercialized kit was good (r=0.615, P<0.001). The urinary uromodulin/urinary creatinine ratio in IgA nephropathy was significantly lower than that in normal controls. The established ELISA method is sensitive and repeatable, and can be used in further studies.
Franquesa, Marcella; Hoogduijn, Martin J.; Ripoll, Elia; Luk, Franka; Salih, Mahdi; Betjes, Michiel G. H.; Torras, Juan; Baan, Carla C.; Grinyó, Josep M.; Merino, Ana Maria
2014-01-01
The research field on extracellular vesicles (EV) has rapidly expanded in recent years due to the therapeutic potential of EV. Adipose tissue human mesenchymal stem cells (ASC) may be a suitable source for therapeutic EV. A major limitation in the field is the lack of standardization of the challenging techniques to isolate and characterize EV. The aim of our study was to incorporate new controls for the detection and quantification of EV derived from ASC and to analyze the applicability and limitations of the available techniques. ASC were cultured in medium supplemented with 5% of vesicles-free fetal bovine serum. The EV were isolated from conditioned medium by differential centrifugation with size filtration (0.2 μm). As a control, non-conditioned culture medium was used (control medium). To detect EV, electron microscopy, conventional flow cytometry, and western blot were used. The quantification of the EV was by total protein quantification, ExoELISA immunoassay, and Nanosight. Cytokines and growth factors in the EV samples were measured by multiplex bead array kit. The EV were detected by electron microscope. Total protein measurement was not useful to quantify EV as the control medium showed similar protein contents as the EV samples. The ExoELISA kits had technical troubles and it was not possible to quantify the concentration of exosomes in the samples. The use of Nanosight enabled quantification and size determination of the EV. It is, however, not possible to distinguish protein aggregates from EV with this method. The technologies for quantification and characterization of the EV need to be improved. In addition, we detected protein contaminants in the EV samples, which make it difficult to determine the real effect of EV in experimental models. It will be crucial in the future to optimize design novel methods for purification and characterization of EV. PMID:25374572
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-16
... DEPARTMENT OF HOMELAND SECURITY Cooperative Research and Development Agreement (CRADA) Opportunity With the Department of Homeland Security for the Development of a Foot-and-Mouth Disease 3ABC ELISA... in developing and validating an ELISA diagnostic kit for detection of Foot and Mouth Disease Virus...
This verification test was conducted according to procedures specifiedin the Test/QA Planfor Verification of Enzyme-Linked Immunosorbent Assay (ELISA) Test Kis for the Quantitative Determination of Endocrine Disrupting Compounds (EDCs) in Aqueous Phase Samples. Deviations to the...
Enzyme-linked immunosorbent assay for ultratrace determination of antibiotics in aqueous samples.
Kumar, Kuldip; Thompson, Anita; Singh, Ashok K; Chander, Yogesh; Gupta, Satish C
2004-01-01
Two commercially available enzyme-linked immunosorbent assay (ELISA) kits that are commonly used for tylosin or tetracycline residues in meat and milk were adapted for ultratrace analysis of these antibiotics in surface and ground waters. These two antibiotics are commonly fed to swine, turkeys, and cattle at subtherapeutic doses for growth promotion purposes. Both ELISA techniques were found to be highly sensitive and selective for the respective antibiotics with detection limits of 0.10 and 0.05 microg L(-1) for tylosin and tetracycline, respectively. The recovery of both tylosin and tetracycline from spiked samples of lake waters, runoff samples, soil saturation extracts, and nanopure water was close to 100%. Tetracycline ELISA was highly specific for tetracycline and chlortetracycline but not for other forms of tetracycline (oxytetracycline, demeclocycline, and doxycycline). Analysis of a few liquid swine manure samples by liquid chromatography-mass spectrometry (LC-MS) showed lower concentrations for chlortetracycline as compared with concentrations obtained using ELISA. However, the concentrations of tylosin from ELISA were comparable with that of LC-MS. The lower concentrations of chlortetracycline obtained by LC-MS in manure samples indicate the presence of other similar or transformed compounds that were detected by ELISA but not determined by LC-MS. These results indicate that both ELISA kits can be useful tools for low-cost screening of tylosin, tetracycline, and chlortetracycline in environmental waters. Furthermore, both ELISA procedures are rapid, portable, and easily adaptable for testing of multiple samples simultaneously.
2013-01-01
Background Toxoplasmosis is one of the most common food borne zoonoses worldwide, and can be a serious life-threatening disease in the congenitally infected fetus and in immunosupressed patients. Among food animals, sheep along with goats and pigs possess the highest incidence of T. gondii cysts in meat, and play a major role as a source of human infection. Methods In this study, a new commercial ELISA kit (PrioCHECK® Toxoplasma Ab SR, Prionics Schlieren-Zurich, Switzerland) for the detection of anti-T. gondii antibodies in serum, plasma and meat juice of sheep, was evaluated by comparing it with the indirect fluorescent antibody test (IFAT), indirect haemagglutination test (IHA) and real-time PCR, on samples from experimentally inoculated and naturally exposed sheep. Results The commercial ELISA detected the infection status in 50% and 100% of sheep orally inoculated with 10,000 T. gondii oocysts (n = 6), from two or three weeks post infection (wpi), respectively, both on serum and plasma samples. Meat juice from all experimentally inoculated sheep collected at slaughter (12 wpi) showed positive ELISA values. In naturally exposed sheep (n = 396), the ELISA showed a very good agreement with IFAT (kappa = 0.91-1.0) and IHA (kappa = 0.96-1.0) performed on serum; and a positive correlation was observed between ELISA values and IFAT titers. By a Receiver Operating Characteristics (ROC) curve analysis, the commercial ELISA had relative sensitivities between 93.33% and 100%, and relative specificities between 96.87% and 100% respect to IFAT and IHA, depending on the considered cut-off value and animal groups tested. Furthermore, the ELISA correctly recognized all animals reacting positive in real-time PCR. The ELISA results on meat juice agreed with those on serum samples in all experimentally inoculated animals, and in 94 out of 96 (97.9%) naturally exposed sheep, when meat juice was tested at a 1:10 dilution. Conclusion The commercial ELISA kit evaluated in this study could represent a valuable tool to improve the surveillance and reporting system for T. gondii in sheep populations at the farm level or for diagnosis at the slaughterhouse, contributing to the control of this widespread zoonosis. PMID:23561035
Analysis of fenbendazole residues in bovine milk by ELISA.
Brandon, David L; Bates, Anne H; Binder, Ronald G; Montague, William C; Whitehand, Linda C; Barker, Steven A
2002-10-09
Fenbendazole residues in bovine milk were analyzed by ELISAs using two monoclonal antibodies. One monoclonal antibody (MAb 587) bound the major benzimidazole anthelmintic drugs, including fenbendazole, oxfendazole, and fenbendazole sulfone. The other (MAb 591) was more specific for fenbendazole, with 13% cross-reactivity with the sulfone and no significant binding to the sulfoxide metabolite. The limit of detection of the ELISA method in the milk matrix was 7 ppb for MAb 587 and 3 ppb for MAb 591. Fenbendazole was administered in feed, drench, and paste form to three groups of dairy cattle. Milk was collected immediately before dosing and then every 12 h for 5 days. The ELISA indicated that residue levels varied widely among individual cows in each group. Fenbendazole levels peaked at approximately 12-24 h and declined rapidly thereafter. Metabolites were detected at much higher levels than the parent compound, peaked at approximately 24-36 h, and declined gradually. Residue levels were undetectable by 72 h. The ELISA data correlated well with the total residues determined by chromatographic analysis, but the use of the two separate ELISAs did not afford an advantage over ELISA with the single, broadly reactive MAb 587. The ELISA method could be used to flag high-residue samples in on-site monitoring of fenbendazole in milk and is a potential tool for studying drug pharmacokinetics.
He, Shengfa; Li, Xin; Wu, Yong; Wu, Shandong; Wu, Zhihua; Yang, Anshu; Tong, Ping; Yuan, Juanli; Gao, Jinyan; Chen, Hongbing
2018-06-01
Bovine milk is a recognized allergenic food source with β-lactoglobulin (BLG) as its major allergen. Reliable detection of BLG epitopes can, therefore, be a useful marker for the presence of milk in processed food products, and for potential allergenicity. At the present, enzyme-linked immunosorbent assays (ELISA) for the detection of BLG are time-consuming and generally not specific to BLG IgE epitopes. In this study, the 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide-activated anti-BLG IgE epitope monoclonal antibody (mAb 1G9) was covalently bound onto the KOH-treated microtiter plate surface. Using this mAb-bound plate in sandwich combination with biotinylated anti-BLG polyclonal antibody-labeled gold nanoparticles, a linear dynamic range between 31.25 and 64 × 10 3 ng mL -1 with a limit of detection for BLG of 0.49 ng mL -1 was obtained, which is 32 times wider and 16 times more sensitive than conventional sandwich ELISA (sELISA). Total recovery of BLG in spiked food samples was found, without matrix effects. Also in partially hydrolyzed infant formulas, the allergenic BLG residues were detected quantitatively. Compared with conventional and commercial BLG detection sELISAs, our sELISA is reliable, highly BLG epitope-specific, user-friendly, and time-saving and allows accurate detection of potentially allergenic residues in different types of processed foods. This improved sELISA protocol can be easily extended to detect other well-identified and characterized food allergens. Graphical abstract IgE epitope mAb-bound plate in sandwich combination with gold probe for sensitive and rapid detection of bovine β-lactoglobulin and its potentially allergenic residues.
Evaluation of a culture-based pathogen identification kit for bacterial causes of bovine mastitis.
Viora, L; Graham, E M; Mellor, D J; Reynolds, K; Simoes, P B A; Geraghty, T E
2014-07-26
Accurate identification of mastitis-causing bacteria supports effective management and can be used to implement selective use of antimicrobials for treatment. The objectives of this study were to compare the results from a culture-based mastitis pathogen detection test kit ('VetoRapid', Vétoquinol) with standard laboratory culture and to evaluate the potential suitability of the test kit to inform a selective treatment programme. Overall 231 quarter milk samples from five UK dairy farms were collected. The sensitivity and specificity of the test kit for the identification of Escherichia coli, Staphylococcus aureus, coagulase-negative staphylococci, Streptococcus uberis and Enterococcus spp. ranged from 17 per cent to 84 per cent and 92 per cent to 98 per cent, respectively. In total, 23 of 68 clinical samples were assigned as meeting the requirement for antimicrobial treatment (Gram-positive organism cultured) according to standard culture results, with the test kit results having sensitivity and specificity of 91 per cent and 78 per cent, respectively. Several occurrences of misidentification are reported, including S. aureus being misidentified as coagulase-negative staphylococci and vice versa. The test kit provides rapid preliminary identification of five common causes of bovine mastitis under UK field conditions and is likely to be suitable for informing selective treatment of clinical mastitis caused by Gram-positive organisms. British Veterinary Association.
Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans
2012-09-01
assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX
Velay, Aurélie; Solis, Morgane; Barth, Heidi; Sohn, Véronique; Moncollin, Anne; Neeb, Amandine; Wendling, Marie-Josée; Fafi-Kremer, Samira
2018-04-01
Tick-borne encephalitis virus (TBEV) diagnosis is mainly based on the detection of viral-specific antibodies in serum. Several commercial assays are available, but published data on their performance remain unclear. We assessed six IgM and six IgG commercial enzyme-linked immunosorbent assay (ELISA) kits (ELISA-1 through ELISA-6) using 94 samples, including precharacterized TBEV-positive samples (n=50) and -negative samples (n=44). The six manufacturers showed satisfactory sensitivity and specificity and high overall agreement for both IgM and IgG. Three manufacturers showed better reproducibility and were the most sensitive (100%) and specific (95.5-98.1%) for both IgM and IgG. Two of them were also in agreement with the clinical interpretation in more than 90% of the cases. All the assays use inactivated virus as antigen, with strains showing approximately 94% homology at the amino acid level. The antigenic format of the assays was discussed to further improve this TBEV diagnostic tool. Copyright © 2017 Elsevier Inc. All rights reserved.
Serological diagnosis of bovine brucellosis using B. melitensis strain B115.
Corrente, Marialaura; Desario, Costantina; Parisi, Antonio; Grandolfo, Erika; Scaltrito, Domenico; Vesco, Gesualdo; Colao, Valeriana; Buonavoglia, Domenico
2015-12-01
Bovine brucellosis is diagnosed by official tests, such as Rose Bengal plate test (RBPT) and Complement Fixation test (CFT). Both tests detect antibodies directed against the lipolysaccharide (LPS) of Brucella cell wall. Despite their good sensitivity, those tests do not discriminate between true positive and false positive serological reactions (FPSR), the latter being generated by animals infected with other Gram negative microorganisms that share components of Brucella LPS. In this study, an antigenic extract from whole Brucella melitensis B115 strain was used to set up an ELISA assay for the serological diagnosis of bovine brucellosis. A total of 148 serum samples from five different groups of animals were tested: Group A: 28 samples from two calves experimentally infected with Yersinia enterocolitica O:9; Group B: 30 samples from bovines infected with Brucella abortus; Group C: 50 samples from brucellosis-free herds; Group D: 20 samples RBPT positive and CFT negative; Group E: 20 samples both RBPT and CFT positive. Group D and Group E serum samples were from brucellosis-free herds. Positive reactions were detected only by RBPT and CFT in calves immunized with Y. enterocolitica O:9. Sera from Group B animals tested positive also in the ELISA assay, whereas sera from the remaining groups were all negative. The results obtained encourage the use of the ELISA assay to implement the serological diagnosis of brucellosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Single-Tier Testing with the C6 Peptide ELISA Kit Compared with Two-Tier Testing for Lyme Disease
Wormser, Gary P.; Schriefer, Martin; Aguero-Rosenfeld, Maria E.; Levin, Andrew; Steere, Allen C.; Nadelman, Robert B.; Nowakowski, John; Marques, Adriana; Johnson, Barbara J. B.; Dumler, J. Stephen
2014-01-01
Background The two-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time and labor; and subjectivity in the interpretation of immunoblots. Methods The diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with two-tier testing. Results The C6 ELISA was significantly more sensitive than two-tier testing with sensitivities of 66.5% (95% C.I.:61.7-71.1) and 35.2% (95%C.I.:30.6-40.1), respectively (p<0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to two-tier testing in sera from Lyme disease patients with early neurological manifestations (88.6% vs. 77.3%, p=0.13) or arthritis (98.3% vs. 95.6%, p= 0.38). Te specificities of C6 ELISA and two-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (p<0.05, 95% C.I. surrounding the 0.6 percentage point difference of 0.04 to 1.15). Conclusions Using a reference standard of two-tier testing, the C6 ELISA as a single step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with two-tier testing in routine clinical practice. PMID:23062467
Nikzad, Jafar; Shahhosseini, Soraya; Tabarzad, Maryam; Nafissi-Varcheh, Nastaran; Torshabi, Maryam
2017-02-14
In the pharmaceutical industry, hard- and soft-shelled capsules are typically made from gelatin, commonly derived from bovine and porcine sources. To ensure that pharmaceutical products comply with halal regulations in Muslim countries (no porcine products allowed), development of a valid, reliable, quick, and most importantly, cost-effective tests are of utmost importance. We developed a species-specific duplex polymerase chain reaction (PCR) assay targeting 149 bp porcine and 271 bp bovine mitochondrial DNA (mtDNA) to simultaneously detect both porcine and bovine DNA (in one reaction at the same time) in gelatin. Some additional simplex PCR tests (targeting 126 bp bovine and 212 bp porcine mtDNA) and real-time PCR using a commercially available kit (for identification of porcine DNA) were used to verify the selectivity and sensitivity of our duplex PCR. After optimization of DNA extraction and PCR methods, hard/soft pharmaceutical gelatin capsules (containing drug) were tested for the presence of porcine and/or bovine DNA. Duplex PCR detected the presence of as little as 0.1% porcine DNA, which was more accurate than the commercially available kit. Of all gelatin capsules tested (n = 24), 50% contained porcine DNA (pure porcine gelatin alone or in combination with bovine gelatin). Duplex PCR presents an easy-to-follow, quick, low-cost and reliable method to simultaneously detect porcine and bovine DNAs (>100 bp) in minute amounts in highly processed gelatin-containing pharmaceutical products (with a 0.1% sensitivity for porcine DNA) which may be used for halal authentication. Simultaneous detection of porcine and bovine DNA in gelatin capsules by duplex PCR.
2016-04-01
streptavidin-phycoerythrin (PE) similar to sandwich enzyme-linked immunosorbent assays ( ELISAs ). The 3 fluorescent markers (2 beads plus PE) allow for...within the kit, this worked out to a set of expensive, problematic, and subjective ELISA . The space on the black-96 well plate was split between cell...ARL US Army Research Laboratory BBB blood–brain barrier CSF cerebral spinal fluid DOD US Department of Defense ELISA enzyme-linked immunosorbent
Impact of Embedded Military Metal Alloys on Skeletal Physiology in an Animal Model
2017-04-04
turnover were completed and statistical comparison performed for each time point. Each ELISA was performed according to the instructions within each kit...expectations for controls. Results of osteocalcin ELISA were evaluated and any results with a coefficient of variation greater than 25% were omitted...Results of TRAP5b ELISA were evaluated and any results with a coefficient of variation greater than 25% were omitted from analysis. Measures of TRAP5b
Japolla, Greice; Cunha-Junior, Jair Pereira; Pajuaba, Ana Claudia Arantes Marquez; Taketomi, Ernesto Akio; Bührer-Sékula, Samira; Bataus, Luiz Artur Mendes; de Souza, Guilherme Rocha Lino
2018-06-01
Bovine herpesvirus type 1 (BoHV-1) is recognized as an important pathogen causing respiratory, reproductive, and neurological disorders in cattle and is associated with economic losses to animal industry. Accurate diagnostic methods are needed for prevention of disease transmission. While the virus neutralization test is considered the gold standard method, it requires maintenance of the virus and cell cultures, which is time consuming and expensive. Serological techniques such as enzyme-linked immunosorbent assay (ELISA) are widely applied, as these are easy to perform and provide quick results. In the present study, a nanogold slot blot inhibition assay was developed for the serological diagnosis of BoHV-1 and compared with standard ELISA and horseradish peroxidase (HRP) slot blot assays. Of 42 serum samples tested by ELISA, 32 (76.2%) were positive and 10 (23.8%), were negative. The sensitivity and specificity of the nanogold slot blot inhibition assay was similar to that observed for ELISA and HRP slot blot assays, and a strong correlation was observed between the tests. Thus, the nanogold slot blot inhibition assay may serve as an efficient and rapid alternative to ELISA in settings, where plate-reading equipment is lacking.
Hagiwara, Ken'ichi; Iwamaru, Yoshifumi; Tabeta, Naoko; Yokoyama, Takashi; Tobiume, Minoru
2017-03-04
A classical type of bovine spongiform encephalopathy (C-BSE), recognized in 1987, had a large impact on public health due to its zoonotic link to variant Creutzfeldt-Jakob disease by the human consumption of dietary products contaminated with the C-BSE prion. Thus, a number of countries implemented BSE surveillance using rapid post-mortem test kits that were approved for detection of the C-BSE prion in the cattle brain. However, as atypical BSE (L- and H-BSE) cases emerged in subsequent years, the efficacy of the kits for the detection of atypical BSE prions became a matter of concern. In response to this, laboratories in the European Union and Canada evaluated the kits used in their countries. Here, we carried out an evaluation study of NippiBL®, a kit currently used for BSE screening in Japan. By applying the kit to cattle brains of field cases of C-BSE and L-BSE, and an experimental case of H-BSE, we showed its comparable sensitivities to C, L-, and H-BSE prions, and satisfactory performance required by the European Food Safety Authority. In addition to NippiBL®, two kits (TeSeE® and FRELISA®) formerly used in Japan were effective for detection of the L-BSE prion, although the two kits were unable to be tested for the H-BSE prion due to the discontinuation of domestic sales during this study. These results indicate that BSE screening in Japan is as effective as those in other countries, and it is unlikely that cases of atypical BSE have been overlooked.
ERIC Educational Resources Information Center
Haussmann, Mark F.; Vleck, Carol M; Farrar, Eugenia S.
2007-01-01
Perceived stress activates the hypothalamus-pituitary-adrenal axis, resulting in the release of glucocorticoids into the systemic circulation. Glucocorticoids cause the elevation of blood glucose, providing the necessary energy for the organism to cope with stress. Here, we outline a laboratory exercise that uses a competitive ELISA kit to…
Maruyama, Haruhiko; Kaneko, Michiko; Otake, Taiga; Kano, Rui; Yamaya, Yoshiki; Watari, Toshihiro; Hasegawa, Atsuhiko; Kamata, Hiroshi
2014-03-01
A disintegrin-like and metalloprotease with thrombospondin type 1 repeat motifs 13 (ADAMTS13) is a von Willebrand factor (vWF)-cleaving protease. Deficiencies in ADAMTS13 activity are known to cause thrombotic diseases in human beings. The present study evaluated whether the human ADAMTS13 activity enzyme-linked immunosorbent assay (ELISA) kit containing human vWF73 (a minimal substrate) and anti-N10 antibody (which specifically recognizes the decapeptide of the C-terminal edge of cleaved vWF by human ADAMTS13) is applicable to the measurement of canine plasma ADAMTS13 activity. Human vWF73 fused with a GST-tag and a His-tag (GST-hvWF73-His) was reacted with recombinant canine (rc)ADAMTS13, canine plasma, and human plasma, and then used in Western blotting using anti-N10 antibody. Linearity and intra- and interassay reproducibility of the human ADAMTS13 activity ELISA kit in canine plasma were further evaluated. Finally, plasma ADAMTS13 activity was measured in 13 healthy dogs and 6 dogs with bacteremia using the human ADAMTS13 activity ELISA kit. Cleaved products with a 28-kDa GST-hvWF73-His were detected specifically in rcADAMTS13 as well as in human ADAMTS13, and also in canine plasma by anti-N10 antibody, showing excellent linearity. Intra-assay coefficient of variation (CV) was 3.0-12.4%, and interassay CV was 11.5-12.5%. The ADAMTS13 activity was significantly lower in dogs with bacteremia than in healthy dogs (P = 0.0025). The current study revealed that the human ADAMTS13 activity ELISA kit is applicable for measurement of canine plasma ADAMTS13 activity to elucidate the pathology of thrombotic diseases in dogs.
Production of monoclonal antibody for the detection of meat and bone meal in animal feed.
Kim, Shin-Hee; Huang, Tung-Shi; Seymour, Thomas A; Wei, Cheng-i; Kempf, Stephen C; Bridgman, C Roger; Clemens, Roger A; An, Haejung
2004-12-15
For the detection of prohibited meat and bone meal (MBM) in animal feed, monoclonal antibodies (MAbs) were raised against heat-stable h-caldesmon purified from bovine intestinal smooth muscle. The obtained hybridoma cells were screened against extracts of the bovine MBM and heat-treated smooth muscle, and MAb 5E12 was identified as having the best performance. Antibody 5E12 did not react with animal feed, milk product, plant proteins, and other ingredients used for commercial animal feed except for the gelatin. This antibody diluted to 100-fold was able to detect MBM mixed in animal feed at 0.05% in an ELISA, and it showed strong affinity toward bovine smooth muscle autoclaved at 130 degrees C. Therefore, this antibody can be used in the ELISA system for field testing of the presence of MBM in animal feed.
Freeman, Karoline; Connock, Martin; Auguste, Peter; Taylor-Phillips, Sian; Mistry, Hema; Shyangdan, Deepson; Court, Rachel; Arasaradnam, Ramesh; Sutcliffe, Paul; Clarke, Aileen
2016-11-01
Systematic reviews and economic modelling of clinical effectiveness and cost-effectiveness of therapeutic monitoring of tumour necrosis factor alpha (TNF-α) inhibitors [using LISA-TRACKER ® enzyme-linked immunosorbent assay (ELISA) kits (Theradiag, Marne La Vallee, France, or Alpha Laboratories, Heriot, UK), TNF-α-Blocker ELISA kits (Immundiagnostik AG, Bensheim, Germany) and Promonitor ® ELISA kits (Proteomika, Progenika Biopharma, Bizkaia, Spain)] versus standard care for Crohn's disease (CD). Multiple electronic databases were searched from inception to December 2014 in order to identify primary studies and meta-analyses. Patients with moderate to severe active CD treated with infliximab (IFX) (Remicade ® , Merck Sharp & Dohme Ltd, Kenilworth, NJ, USA) or adalimumab (ADA) (Humira ® , AbbVie Inc., North Chicago, IL, USA). Monitoring of serum anti-TNF-α (IFX or ADA) and/or of anti-drug antibody levels using test assays with a test-treatment algorithm. Standard care. Any patient-related outcome, test agreement and cost-effectiveness estimates. The quality assessments used recognised checklists (Quality Assessment of Diagnostic Accuracy Studies-2, Cochrane, Philips and Consolidated Health Economic Evaluation Reporting Standards). Evidence was synthesised using narrative review and meta-analysis. A Markov model was built in TreeAge Pro 2013 (TreeAge Software, Inc., Williamstown, MA, USA). The model had a 4-week cycle and a 10-year time horizon, adopted a NHS and Personal Social Services perspective and used a linked evidence approach. Costs were adjusted to 2013/14 prices and discounted at 3.5%. We included 68 out of 2434 and 4 out of 2466 studies for the clinical effectiveness and cost-effectiveness reviews, respectively. Twenty-three studies comparing test methods were identified. Evidence on test concordance was sparse and contradictory, offering scant data for a linked evidence approach. Three studies [two randomised controlled trials (RCTs) and one retrospective observational study] investigated outcomes following implementation of a test algorithm. None used the specified commercial ELISA immunoassay test kits. Neither of the two RCTs demonstrated clinical benefit of a test-treatment regimen. A meta-analysis of 31 studies to estimate test accuracy for predicting clinical status indicated that 20-30% of test results are likely to be inaccurate. The four cost-effectiveness studies suggested that testing results in small cost reductions. In the economic analysis the base-case analysis showed that standard practice (no testing/therapeutic monitoring with the intervention tests) was more costly and more effective than testing for IFX. Sensitivity and scenario analyses gave similar results. The probabilistic sensitivity analysis indicated a 92% likelihood that the 'no-testing' strategy was cost-effective at a willingness to pay of £20,000 per quality-adjusted life-year. Rigorous systematic reviews were undertaken; however, the underlying evidence base was poor or lacking. There was uncertainty about a linked evidence approach and a lack of gold standard for assay comparison. The only comparative evidence available for economic evaluation was for assays other than the intervention assays. Our finding that testing is not cost-effective for IFX should be viewed cautiously in view of the limited evidence. Clinicians should be mindful of variation in performance of different assays and of the absence of standardised approaches to patient assessment and treatment algorithms. There is substantial variation in the underlying treatment pathways and uncertainty in the relative effectiveness of assay- and test-based treatment algorithms, which requires further investigation. There is very little research evidence on ADA or on drug monitoring in children with CD, and conclusions on cost-effectiveness could not be reached for these. This study is registered as PROSPERO CRD42014015278. The National Institute for Health Research Health Technology Assessment programme.
A Novel Blocking ELISA for Detection of Antibodies against Hepatitis E Virus in Domestic Pigs.
Chen, Yiyang; Zhao, Qin; Liu, Baoyuan; Wang, Lizhen; Sun, Yani; Li, Huixia; Wang, Xinjie; Syed, Shahid Faraz; Zhang, Gaiping; Zhou, En-Min
2016-01-01
Hepatitis E virus (HEV) infects both humans and animals, with an overall human mortality rate generally less than 1%, but as high as 20% among pregnant women. HEV strains fall into 4 major genotypes. Zoonotic genotypes 3 and 4 associate with sporadic human and animal HEV cases in many industrialized countries. To date, collective evidence implicates pigs as the main HEV reservoir, justifying the importance of monitoring HEV infection rates in pig herds to prevent human illness. Due to the lack of a robust in vitro cell culture system for viral propagation, no "gold standard" assay has yet been developed to detect HEV infection in domestic pigs. 1E4, a monoclonal antibody (mAb) specific for the C-terminal 268 amino acids of HEV genotype 4 ORF2 capsid protein (sORF2-C), was generated and conjugated to horseradish peroxidase (HRP) for use in a blocking ELISA (bELISA). Optimal sORF2-C coating antigen concentration (8 μg/ml), HRP-1E4 dilution (1:1000), and test pig serum dilution (1:20) were determined using a checkerboard titration test. A cut-off value of 16.9% was chosen to differentiate between positive vs. negative sera after mean percent inhibition (PI) testing of 230 negative pig sera. Compared with the indirect ELISA (iELISA), western blot, and a commercial ELISA kit for detecting anti-HEV antibodies in human sera, the bELISA showed no statistical differences and statistically high coincidence of 93.23%, 92%, and 95% with the other tests, respectively. A blocking ELISA (bELISA) for detecting anti-HEV antibodies in pig serum samples was developed with high sensitivity and high specificity comparable to that of the indirect ELISA. The bELISA results exhibited high agreement with iELISA, western blot, and a commercial ELISA kit designed to detect human anti-HEV antibodies. Therefore, bELISA should serve as an ideal method for large-scale serological investigation of anti-HEV antibodies in domestic pigs.
Single-tier testing with the C6 peptide ELISA kit compared with two-tier testing for Lyme disease.
Wormser, Gary P; Schriefer, Martin; Aguero-Rosenfeld, Maria E; Levin, Andrew; Steere, Allen C; Nadelman, Robert B; Nowakowski, John; Marques, Adriana; Johnson, Barbara J B; Dumler, J Stephen
2013-01-01
For the diagnosis of Lyme disease, the 2-tier serologic testing protocol for Lyme disease has a number of shortcomings including low sensitivity in early disease; increased cost, time, and labor; and subjectivity in the interpretation of immunoblots. In this study, the diagnostic accuracy of a single-tier commercial C6 ELISA kit was compared with 2-tier testing. The results showed that the C6 ELISA was significantly more sensitive than 2-tier testing with sensitivities of 66.5% (95% confidence interval [CI] 61.7-71.1) and 35.2% (95% CI 30.6-40.1), respectively (P < 0.001) in 403 sera from patients with erythema migrans. The C6 ELISA had sensitivity statistically comparable to 2-tier testing in sera from Lyme disease patients with early neurologic manifestations (88.6% versus 77.3%, P = 0.13) or arthritis (98.3% versus 95.6%, P = 0.38). The specificities of C6 ELISA and 2-tier testing in over 2200 blood donors, patients with other conditions, and Lyme disease vaccine recipients were found to be 98.9% and 99.5%, respectively (P < 0.05, 95% CI surrounding the 0.6 percentage point difference of 0.04 to 1.15). In conclusion, using a reference standard of 2-tier testing, the C6 ELISA as a single-step serodiagnostic test provided increased sensitivity in early Lyme disease with comparable sensitivity in later manifestations of Lyme disease. The C6 ELISA had slightly decreased specificity. Future studies should evaluate the performance of the C6 ELISA compared with 2-tier testing in routine clinical practice. Copyright © 2013 Elsevier Inc. All rights reserved.
Wang, Lei; Wang, Xiaoxia; Li, Ying; Cheng, Zeneng
2016-01-01
Etanercept is the first tumor necrosis factor inhibitor to be approved for rheumatic disease treatment. Its in vivo concentration is usually detected with commercial enzyme-linked immunosorbent assay (ELISA) kits; specifically, previous researchers have mostly used double-antibody sandwich ELISA technology. Double-antibody sandwich ELISA is employed to detect the total etanercept rather than biologically active etanercept, which is more relevant in terms of therapeutic drug monitoring. In this work, a sensitive ELISA that employed its antigen TNF-α to capture biologically active etanercept for concentration detection was established and validated for etanercept pharmacokinetic (PK) study in patients with ankylosing spondylitis (AS). The proposed assay was demonstrated to be precise and accurate over the linear range of 12.5-400pg/mL. The intra- and inter-assay relative standard deviation ranged from 3.9 to 12.2% and 6.2 to 11.1%, respectively, and recovery varied between 90.1 and 99.7%, confirming the assay's reliability. The effectiveness and accuracy of the assay was also validated according to quality samples containing etanercept with different TNF-α concentrations, and with plasma samples from patients with AS. To complete the study, both the proposed assay and double-antibody sandwich ELISA were applied to the PK study of etanercept in patients and compared. The multiple-dose results of both analytical methods were consistent, while the drug exposure of the first dose as-detected by the proposed assay was lower than that detected by double-antibody sandwich ELISA. In conclusion, the proposed ELISA was shown to provide more accurate concentration data for therapeutic drug monitoring in comparison to commercial ELISA kits. Copyright © 2015 Elsevier B.V. All rights reserved.
Ponterio, Eleonora; Di Bartolo, Ilaria; Orrù, Ginevra; Liciardi, Manuel; Ostanello, Fabio; Ruggeri, Franco Maria
2014-06-16
The hepatitis E virus (HEV) has been detected in both humans and animals, particularly pigs, worldwide. Several evidences, including human infection following consumption of raw contaminated meat, suggest a zoonotic transmission of HEV. In Italy, large circulation of genotype 3 HEV has been reported in swine, and recent studies have confirmed the involvement of this genotype in autochthonous human cases. In this study 111 sera collected from healthy pigs in two Italian regions were tested for anti-HEV IgG antibodies. For specific HEV antibody detection in swine, we developed ELISA and Western blotting methods, using a truncated capsid (ORF2) protein lacking the first 111 amino acids of a swine HEV genotype 3 strain. The ORF2-based ELISA revealed anti-HEV antibodies in 104 out of 111 pigs compared with 102 detected with a commercial ELISA kit. A lower number of sera reacted with the recombinant ORF2 protein in a Western blotting format (81/111). Using a Latent class analysis (LCA), the estimated sensitivities for ELISA-ORF2 and ELISA-kit tests were 0.961 and 0.936, respectively, whereas specificities were 0.599 and 0.475. The estimated sensitivity of Western blotting was 0.775, and the specificity was 0.944. The overall results confirm the high prevalence of HEV seropositive healthy pigs in Italy. Through comparisons with a commercial ELISA test, the swine genotype 3 HEV antigen produced in this study was proven suitable to detect anti-HEV antibodies in pig sera by both ELISA and Western Blotting.
Gluten detection in foods available in the United States - a market survey.
Sharma, Girdhari M; Pereira, Marion; Williams, Kristina M
2015-02-15
Many gluten-free (GF) food choices are now available in supermarkets. However, the unintentional presence of gluten in these foods poses a serious health risk to wheat-allergic and celiac patients. Different GF labelled foods (275) and non-GF labelled foods, without wheat/rye/barley on the ingredient label (186), were analysed for gluten content by two different enzyme linked immunosorbent assay (ELISA) kits. Considering the gluten threshold of 20ppm, GF labelled foods had 98.9% GF labelling compliance with 1.1% (3 out of 275) of foods being mislabelled/misbranded. Among the non-GF labelled foods, 19.4% (36 out of 186) of foods had >20ppm of gluten, as measured by at least one ELISA kit, of which 19 foods had >100ppm of gluten. The presence of oats in non-GF labelled foods was strongly correlated with a positive ELISA result. Gluten was also found in a significant number of foods with gluten/wheat-related advisory warnings. Published by Elsevier Ltd.
Bovine herpesvirus 1: within-herd seroprevalence and antibody levels in bulk-tank milk.
Martínez, S; Yus, E; Sanjuán, M L; Camino, F; Eiras, M C; Arnaiz, I; Diéguez, F J
2016-12-01
The aim of the present study was to establish a relationship between the results obtained with the enzyme-linked immunosorbent assay (ELISA) technique for antibodies (against bovine herpesvirus 1) in serum and those in milk at the herd level. For this purpose, 275 samples of bulk-tank milk were analysed with glycoprotein E (gE) antibody ELISA and 207 more were analysed with glycoprotein B (gB) antibody ELISA (482 in total). All of these samples came from dairy herds whose seroprevalence was also evaluated. The results of this study were then used to analyse the sensitivity of the bulk-tankmilk test in detecting herds with a high risk of active infection (>60% seroprevalence) and its specificity in detecting those with few (<20%) or no seropositive animals. In regard to the reference test (results in blood serum), the sensitivity of the bulk-tankmilk test in detecting herds with >60% seropositive animals was 100% for both gE and gB ELISAs. The specificity figures, for gE and gB ELISAs, respectively, were 88.4% and 99.1% for infection-free herds and 72.6% and 96% for herds with <20% seroprevalence. In a quantitative approach, Pearson's correlation coefficients, reported as a measure of linear association between herd seroprevalences and transformed optical density values recorded in bulk-tank milk, were -0.63 for gE ELISA and 0.67 for gB ELISA. © OIE (World Organisation for Animal Health), 2016.
Fetal sex alters maternal anti-Mullerian hormone during pregnancy in cattle.
Stojsin-Carter, Anja; Costa, Nathalia N; De Morais, Rodrigo; De Bem, Tiago H; Costa, Mayra P; Carter, Timothy F; Gillis, Daniel J; Neal, Michael S; Ohashi, Otavio M; Miranda, Moyses S; Meirelles, Flavio V; Favetta, Laura A; King, W Allan
2017-11-01
Anti-Mullerian hormone (AMH) is expressed by both male and female fetuses during mammalian development, with males expressing AMH earlier and at significantly higher concentration. The aim of the current study was to explore the potential impact of pregnancy and fetal sex on maternal AMH and to determine if plasma (Pl) AMH or placenta intercotyledonary membrane and cotyledonary AMH receptor 2 (AMHR2) mRNA expression differ in pregnant cows carrying male vs. female fetuses. AMH levels in blood were measured using a bovine optimized ELISA kit. Cows pregnant with a male fetus were observed to have a significantly greater difference in Pl AMH between day 35 and 135 of gestation. Average fetal AMH level between 54 and 220days of gestation was also observed to be significantly higher in male vs. female fetuses. Intercotyledonary membranes and cotyledons were found to express AMHR2 between days 38 and 80 of gestation at similar levels in both fetal sexes. These findings support the hypothesis that fetal sex alters maternal Pl AMH during pregnancy in cattle. Copyright © 2017 Elsevier B.V. All rights reserved.
Uzcanga, Graciela L; Pérez-Rojas, Yenis; Camargo, Rocío; Izquier, Adriana; Noda, José A; Chacín, Ronny; Parra, Nereida; Ron, Lenin; Rodríguez-Hidalgo, Richar; Bubis, José
2016-03-15
Previous studies have shown that a 64-kDa antigen (p64) that was purified from the Venezuelan TeAp-N/D1 isolate of Trypanosoma (Trypanozoon) equiperdum corresponds to the soluble form of its predominant variant surface glycoprotein (VSG), and exhibited cross-reactivity with Trypanosoma (Duttonella) vivax. The course of experimental acute infections of bovines with T. vivax were followed by measuring whole anti-p64 antibodies and specific anti-p64 IgG and IgM antibodies in animal sera by indirect enzyme-linked immunosorbent assay (ELISA). The value of p64 to diagnose bovine trypanosomosis was also examined using 350 sera from healthy and T. vivax-infected cows living in a trypanosomosis-endemic and enzootic stable area, and 48 sera obtained during a trypanosomosis outbreak. Serological assays showed that ∼ 70-80% of the infected sera contained anti-p64 antibodies, based on the comparative immunodetection of the T. equiperdum clarified antigenic fraction used as a reference test. In the absence of a gold standard, Bayesian analysis for multiple testing estimated a sensitivity and specificity of 71.6% and 98.8%, respectively, for the indirect ELISA using p64 as antigen. An apparent prevalence of 37.7% for bovine trypanosomosis infection was also estimated with a Bayesian approach when the p64 ELISA test was used. Employing blood from acute infected cows, the indirect ELISA response against p64 was contrasted with the microhematocrit centrifuge method and analyses by polymerase chain reaction (PCR) using specific primers targeting the inter-specific length variation of the internal transcribed spacer 1 region of the 18S ribosomal gene. The efficiency of p64 for the detection of anti-trypanosome antibodies in acute infected bovines was also corroborated serologically by comparing its response to that of the Indonesian Trypanosoma evansi Rode Trypanozoon antigen type (RoTat) 1.2 VSG, which possesses high specificity and sensitivity. As expected, PCR was the best method to detect parasites and diagnose bovine trypanosomosis; however, a substantial level of concordance (Cohen's κ=0.667) was obtained when serological tests using p64 and RoTat 1.2 VSG were compared. Additionally, an agglutination assay was designed using p64 covalently coupled to carboxylate-modified latex microparticles, which was proven here to be suitable for a fast qualitative diagnosis of bovine trypanosomosis. Copyright © 2016 Elsevier B.V. All rights reserved.
Development and validation of an ELISA kit (YF MAC-HD) to detect IgM to yellow fever virus.
Basile, Alison Jane; Goodman, Christin; Horiuchi, Kalanthe; Laven, Janeen; Panella, Amanda J; Kosoy, Olga; Lanciotti, Robert S; Johnson, Barbara W
2015-12-01
Yellow fever virus (YFV) is endemic in tropical and sub-tropical regions of the world, with around 180,000 human infections a year occurring in Africa. Serologic testing is the chief laboratory diagnostic means of identifying an outbreak and to inform the decision to commence a vaccination campaign. The World Health Organization disseminates the reagents for YFV testing to African reference laboratories, and the US Centers for Disease Control and Prevention (CDC) is charged with producing and providing these reagents. The CDC M-antibody capture ELISA is a 2-day test, requiring titration of reagents when new lots are received, which leads to inconsistency in testing and wastage of material. Here we describe the development of a kit-based assay (YF MAC-HD) based upon the CDC method, that is completed in approximately 3.5h, with equivocal samples being reflexed to an overnight protocol. The kit exhibits >90% accuracy when compared to the 2-day test. The kits were designed for use with a minimum of equipment and are stored at 4°C, removing the need for freezing capacity. This kit is capable of tolerating temporary sub-optimal storage conditions which will ease shipping or power outage concerns, and a shelf life of >6 months was demonstrated with no deterioration in accuracy. All reagents necessary to run the YF MAC-HD are included in the kit and are single-use, with 8 or 24 sample options per kit. Field trials are envisioned for the near future, which will enable refinement of the method. The use of the YF MAC-HD is anticipated to reduce materials wastage, and improve the quality and consistency of YFV serologic testing in endemic areas. Published by Elsevier B.V.
Evaluation of a Real-Time PCR Kit for Detecting Escherichia coli O157 in Bovine Fecal Samples
Bono, James L.; Keen, James E.; Miller, Laura C.; Fox, James M.; Chitko-McKown, Carol G.; Heaton, Michael P.; Laegreid, William W.
2004-01-01
A commercially available real-time, rapid PCR test was evaluated for its ability to detect Escherichia coli O157. Both the sensitivity and specificity of the assay were 99% for isolates in pure culture. The assay detected 1 CFU of E. coli O157:H7 g−1 in artificially inoculated bovine feces following enrichment. PMID:15006817
Udomsin, Orapin; Krittanai, Supaluk; Kitisripanya, Tharita; Tanaka, Hiroyuki; Putalun, Waraporn
2017-01-01
Background: Puerarin (PUE) is a phytoestrogen found in Pueraria candollei and Pueraria lobata. These plants are substantial for traditional medicine in various Asian countries. PUE is a key marker that can be found only in the Pueraria species. Objective: To establish the method for determination of PUE content which is required for quality control of pharmaceutical products. Materials and Methods: PUE-cationized bovine serum albumin conjugate was created via Mannich reaction. After the rabbit immunization, the obtain anti-PUE polyclonal antibody (PAb) was used to develop an enzyme-linked immunosorbent assay (ELISA). Results: An anti-PUE PAb possess a great sensitivity and specificity. The cross-reactivity analysis shows no cross-reaction of an established antibody against other substances. In addition, we successfully developed an indirect competitive ELISA (icELISA) for the quantitative analysis of PUE. The result of method validation conforms to acceptance criteria and correlates with high-performance liquid chromatography, the reference method. The icELISA was applied to determine PUE content in Pueraria spp. plant samples and its derived pharmaceutical products. Conclusion: This highly specific immunogen was created from the Mannich reaction. An icELISA can also be applied to other research propose in the further studies. SUMMARY The new immunogen conjugated (puerarin-cBSA) via Mannich reaction was successfully in rising of antibody against puerarin (PUE)The obtained anti-PUE polyclonal antibody (PAb) was high sensitivity and specificity to PUEAn indirect competitive enzyme-linked immunosorbent assay (icELISA) was developed and validated using anti-PUE PAbThe established icELISA was applied to determine PUE content in various tuberous root of Pueraria sppMoreover, icELISA method can be applicable in Pueraria spp. derived products. Abbreviations used: PUE: Puerarin; PAb: Polyclonal antibody; ELISA: Enzyme-linked immunosorbent assay; icELISA: Indirect competitive ELISA; cBSA: Cationized bovine serum albumin. PMID:29491643
Japhet, Margaret Oluwatoyin; Adewumi, Moses Olubusuyi; Adesina, Olufisayo Adeyemi; Donbraye, Emmanuel
2016-01-01
Blood transfusion service centers in Nigeria screen donated blood for markers of HIV infection using antibody- (Ab) based rapid test and in some centers, positives are re-tested using Ab-based ELISA. Paucity of data exists on p24 antigen prevalence among HIV Ab-negative donors in Nigeria. This study aims at detecting HIV p24 antigen among prospective blood donors in Osun State, Nigeria. Prospective blood donors negative for HIV antibodies using Determine test kit were re-tested using BIORAD GENSCREEN Ultra Ag-Ab ELISA kit, a fourth-generation ELISA kit that detects HIV antibodies/p24 antigen. Of the 169 HIV Ab-negative prospective donors, 10 (5.9%) were positive for HIV p24 antigen and 70% (7/10) of them were in the age range 18-30 years. Results of this study show that blood transfusion is still one of the major routes of HIV transmission in Nigeria and a higher proportion is among youth. Inclusion of p24 antigen testing into the blood donor screening will help reduce transfusion associated HIV in Nigeria if Nucleic Acid Testing (NAT) of all blood donor samples is not affordable; also, HIV enlightenment programs tailored toward youth may help reduce this rate among donors since more young people donate blood in low/middle-income countries than in high-income countries.
Field evaluation of a rapid diagnostic test to detect antibodies in human toxocariasis.
Lim, P K C; Yamasaki, H; Mak, J W; Wong, S F; Chong, C W; Yap, I K S; Ambu, S; Kumarasamy, V
2015-08-01
Human toxocariasis which is caused mainly by the larvae of Toxocara canis and Toxocara cati, is a worldwide zoonotic disease that can be a potentially serious human infection. The enzyme-linked immunosorbent assay (ELISA) using T. canis excretory-secretory (TES) antigens harvested from T. canis larvae is currently the serological test for confirming toxocariasis. An alternative to producing large amounts of Toxocara TES and improved diagnosis for toxocariasis is through the development of highly specific recombinant antigens such as the T. canis second stage larva excretory-secretory 30 kDa protein (recTES-30). The aim of this study was to evaluate the sensitivity and specificity of a rapid diagnostic kit (RDT, named as iToxocara kit) in comparison to recTES-30 ELISA in Serendah Orang Asli village in Selangor, Malaysia. A total of 133 subjects were included in the study. The overall prevalence rates by ELISA and RDT were 29.3% and 33.1%, respectively, with more positive cases detected in males than females. However, no association was found between toxocariasis and gender or age. The percentage sensitivity, specificity, positive predictive value and negative predictive value of RDT were 85.7%, 90.1%, 80% and 93.2%, respectively. The prevalence for toxocariasis in this population using both ELISA and RDT was 27.1% (36/133) and the K-concordance test suggested good agreement of the two tests with a Cohen's kappa of 0.722, P<0.01. In addition, the followed-up Spearman rank correlation showed a moderately high correlation at R=0.704 and P<0.01. In conclusion, the RDT kit was faster and easier to use than an ELISA and is useful for the laboratory diagnosis of hospitalized cases of toxocariasis. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
Lowenski, Steeve; Durand, Benoit; Bahuon, Céline; Zientara, Stéphan; Lecollinet, Sylvie
2017-01-01
West Nile Fever is a zoonotic disease caused by a mosquito-borne flavivirus, WNV. By its clinical sensitivity to the disease, the horse is a useful sentinel of infection. Because of the virus’ low-level, short-term viraemia in horses, the primary tools used to diagnose WNV are serological tests. Inter-laboratory proficiency tests (ILPTs) were held in 2010 and 2013 to evaluate WNV serological diagnostic tools suited for the European network of National Reference Laboratories (NRLs) for equine diseases. These ILPTs were designed to evaluate the laboratories’ and methods’ performances in detecting WNV infection in horses through serology. The detection of WNV immunoglobulin G (IgG) antibodies by ELISA is widely used in Europe, with 17 NRLs in 2010 and 20 NRLs in 2013 using IgG WNV assays. Thanks to the development of new commercial IgM capture kits, WNV IgM capture ELISAs were rapidly implemented in NRLs between 2010 (4 NRLs) and 2013 (13 NRLs). The use of kits allowed the quick standardisation of WNV IgG and IgM detection assays in NRLs with more than 95% (20/21) and 100% (13/13) of satisfactory results respectively in 2013. Conversely, virus neutralisation tests (VNTs) were implemented in 33% (7/21) of NRLs in 2013 and their low sensitivity was evidenced in 29% (2/7) of NRLs during this ILPT. A comparison of serological diagnostic methods highlighted the higher sensitivity of IgG ELISAs compared to WNV VNTs. They also revealed that the low specificity of IgG ELISA kits meant that it could detect animals infected with other flaviviruses. In contrast VNT and IgM ELISA assays were highly specific and did not detect antibodies against related flaviviruses. These results argue in favour of the need for and development of new, specific serological diagnostic assays that could be easily transferred to partner laboratories. PMID:28915240
Hori, Hisae; Hattori, Shunji; Inouye, Sakae; Kimura, Akinori; Irie, Shinkichi; Miyazawa, Hiroshi; Sakaguchi, Masahiro
2002-10-01
Anaphylaxis to measles, mumps, and rubella vaccines has been reported. It has been found that most of these reactions to live vaccines are caused by type I allergy with the bovine gelatin present in the vaccines as an allergen. Gelatin mainly includes denatured type I collagen, which consists of alpha1 and alpha2 chains. We previously reported that allergic reactions to gelatin are caused by the type I collagen alpha2 (alpha2[I]) chain. To aid in the development of gelatin that has little or no allergenicity in human subjects, we investigated epitopes of bovine alpha2(I) chain with use of IgE in gelatin-sensitive children. Serum samples were collected from 15 patients who had systemic allergic reactions to vaccines and high levels of specific IgE to bovine gelatin. Eleven overlapping recombinant proteins that cover bovine alpha2(I) were prepared with a bacterial expression vector. We examined IgE reactivity to these recombinant proteins by means of ELISA. Fifteen peptides covering a major reactive recombinant protein were synthesized. The IgE-reacting epitope was identified by means of IgE-ELISA inhibition with these synthetic peptides and pooled serum from the patients. We found that of the 15 patients, 13 showed IgE reactivity to a recombinant protein (no. 3) spanning the central region of the collagenous domain ((418)Gly-(662)Pro). Furthermore, all 13 patients showed IgE reactivity to the 4-kd recombinant protein (no. 3a) spanning the region from (461)Pro to (500)Glu. In IgE-ELISA inhibition we found that a minimum IgE epitope of gelatin allergen was composed of the 10-amino-acid sequence (485)Ile-Pro-Gly-Glu-Phe-Gly-Leu-Pro-Gly-Pro(494). This sequence is not observed in the human type I collagen alpha1 and alpha2 chains, nor is it found in the bovine type I collagen alpha1 chain. We found that Ile-Pro-Gly-Glu-Phe-Gly-Leu-Pro-Gly-Pro is a major IgE epitope of the alpha2 chain of bovine type I collagen in patients with gelatin allergy. The degree of anaphylaxis to gelatin in vaccines might be reduced by digestion of this IgE-binding site in gelatin.
Singha, Harisankar; Goyal, Sachin K; Malik, Praveen; Khurana, Sandip K; Singh, Raj K
2013-12-01
Equine infectious anemia (EIA)-a retroviral disease caused by equine infectious anemia virus (EIAV)-is a chronic, debilitating disease of horses, mules, and donkeys. EIAV infection has been reported worldwide and is recognized as pathogen of significant economic importance to the horse industry. This disease falls under regulatory control program in many countries including India. Control of EIA is based on identification of inapparent carriers by detection of antibodies to EIAV in serologic tests and "Stamping Out" policy. The current internationally accepted test for diagnosis of EIA is the agar gel immune-diffusion test (AGID), which detects antibodies to the major gag gene (p26) product. The objective of this study was to develop recombinant p26 based in-house immunoassays [enzyme linked immunosorbent assays (ELISA), and AGID] for EIA diagnosis. The synthetic p26 gene of EIAV was expressed in Escherichia coli and diagnostic potential of recombinant p26 protein were evaluated in ELISA and AGID on 7,150 and 1,200 equine serum samples, respectively, and compared with commercial standard AGID kit. The relative sensitivity and specificity of the newly developed ELISA were 100 and 98.6 %, respectively. Whereas, relative sensitivity and specificity of the newly developed AGID were in complete agreement in respect to commercial AGID kit. Here, we have reported the validation of an ELISA and AGID on large number of equine serum samples using recombinant p26 protein produced from synthetic gene which does not require handling of pathogenic EIAV. Since the indigenously developed reagents would be economical than commercial diagnostic kit, the rp26 based-immunoassays could be adopted for the sero-diagnosis and control of EIA in India.
Abrantes-Lemos, Clarice Pires; Nakhle, Maria Cristina; Damiao, Aderson Omar Mourao Cintra; Sipahi, Aytan Miranda; Carrilho, Flair José; Cancado, Eduardo Luiz R
2010-01-01
Sensitivity and specificity of anti-human tissue transglutaminase antibodies (anti-htTGA) seem to be superior to those of anti-tissue transglutaminase of guinea pig (anti-gptTGA) for screening patients with celiac disease (CD), but there are still controversies. The aim of this study was to evaluate the performance of two INOVA ELISA kits to detect IgA anti-htTGA and anti-gptTGA in patients with and without CD. The study groups were comprised of 49 anti-endomysial antibody (EMA)-positive untreated-CD, and 123 controls (EMA-negative treated CD, EMA-negative chronic diarrhea, autoimmune hepatitis, inflammatory bowel disease and healthy people). The agreement between the two ELISAs was statistically significant in all study groups and there was no significant difference between them (92.7% agreement; kappa = 0.70; kappa p = 0.001; McNemar p = 1). All patients with serum reactivity of more than 100 units had histologic diagnosis of CD. In seven of 10 patients with treated-CD who had control biopsies, villous atrophy was still present in four who tested positive by both kits. Two of three celiacs with histologic remission tested positive for both anti-tTGA. the anti-gptTGA and anti-htTGA determination were equally efficient in identifying patients with untreated-CD with high titers of EMA. Whatever the anti-tTGA ELISA used, the reactivity above 100 units was always related to active CD diagnosed by histologic alterations in intestinal biopsies. The anti-tTGA reactivity by both kits was not only similar in determining histologic activity in the follow-up of CD after a gluten free diet, but also in identifying positive sera from the control groups, regardless if CD has been confirmed by duodenal biopsies.
Dehkordi, Farhad Safarpoor; Borujeni, Mohammad Reza Haghighi; Rahimi, Ebrahim; Abdizadeh, Rahman
2013-02-01
This study was conducted to determine the presence of Toxoplasma gondii in animal milk samples in Iran. From a total of 395 dairy herds in three provinces of Iran, 66 bovine, 58 ovine, 54 caprine, 33 buffalo, and 30 camel herds were studied, and from these parts of Iran, 200 bovine, 185 ovine, 180 caprine, 164 buffalo, and 160 camel milk samples were collected from various seasons. Samples were tested for Toxoplasma gondii by cell line culture, enzyme-linked immunosorbent assay (ELISA), and polymerase chain reaction (PCR) technique. Only the results of cell line cultivation were confirmed by bioassay in cat. Results indicated that all herds were infected with Toxoplasma gondii. The culture method showed that 51 out of 889 milk samples (5.73%) were positive for Toxoplasma gondii, and all 51 positive culture results were positive with bioassay in cat. The Fars province had the highest prevalence of Toxoplasma gondii (6.84%). The ELISA test showed that 41 milk samples (4.61%) were positive for the presence of Toxoplasma gondii, while the PCR showed that 46 milk samples were positive for Toxoplasma gondii. The results showed higher sensitivity of PCR and higher specificity of ELISA. Caprine had the highest (10%) and camel had the lowest (3.12%) prevalence rate of parasite. The summer season had the highest (76.47%) but winter (3.92) had the lowest incidence of Toxoplasma gondii. This study is the first prevalence report of direct detection of Toxoplasma gondii in animal milk samples in Iran.
USDA-ARS?s Scientific Manuscript database
Case Description: 1,081 newborn calves from a commercial dairy were tested for bovine viral diarrhea virus antigen by pooled RT-PCR as part of a screening program. Ear tissue from twenty six calves initially tested positive and 14 confirmed positive with antigen capture ELISA two weeks later (1.3...
Li, Y S; Zhou, Y; Meng, X Y; Zhang, Y Y; Liu, J Q; Zhang, Y; Wang, N N; Hu, P; Lu, S Y; Ren, H L; Liu, Z S
2014-11-15
A dual labeled probe was synthesized by coating gold nanoparticles (AuNPs) with anti-κ-CN monoclonal antibody (McAb) and horseradish peroxidase (HRP) enzyme on their surface. The McAb was used as detector and HRP was used as label for signal amplification catalytically oxidize the substrate. AuNPs were used as bridges between the McAb and HRP. Based on the probe, an immunoassay was developed for ultrasensitive detection of κ-CN in bovine milk samples. The assay has a linear response range within 4.2-560 ng mL(-1). The limit of detection (LOD) was 4.2 ng mL(-1) which was 10 times lower than that of traditional McAb-HRP based ELISA. The recoveries of κ-CN from three brand bovine milk samples were from 95.8% to 111.0% that had a good correlation (R(2)=0.998) with those obtained by official standard Kjeldahl method. For higher sensitivity and as simple as the traditional ELISA, the developed immunoassay could provide an alternative approach for ultrasensitive detection of κ-CN in bovine milk sample. Copyright © 2014 Elsevier B.V. All rights reserved.
Detection of cow milk adulteration in yak milk by ELISA.
Ren, Q R; Zhang, H; Guo, H Y; Jiang, L; Tian, M; Ren, F Z
2014-10-01
In the current study, a simple, sensitive, and specific ELISA assay using a high-affinity anti-bovine β-casein monoclonal antibody was developed for the rapid detection of cow milk in adulterated yak milk. The developed ELISA was highly specific and could be applied to detect bovine β-casein (10-8,000 μg/mL) and cow milk (1:1,300 to 1:2 dilution) in yak milk. Cross-reactivity was <1% when tested against yak milk. The linear range of adulterant concentration was 1 to 80% (vol/vol) and the minimum detection limit was 1% (vol/vol) cow milk in yak milk. Different treatments, including heating, acidification, and rennet addition, did not interfere with the assay. Moreover, the results were highly reproducible (coefficient of variation <10%) and we detected no significant differences between known and estimated values. Therefore, this assay is appropriate for the routine analysis of yak milk adulterated with cow milk. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Production and Characterization of Monoclonal Antibody against Recombinant Virus Coat Protein CP42.
Shibaei, Naeimeh; Majidi, Jafar; Razavi, Khadijeh; Karkhane, Ali Asghar; Sokhandan-Bashir, Nemat; Aghebati-Maleki, Leili
2017-02-01
There are many studies related to the production of a ELISA kit for diagnosing virus infections. However, production of most kits depends on purification of whole virus particles, which involves the use of costly equipment and reagents. The purpose of this study was to check out if the anti-CP42 antibodies could be used as a diagnostic assay for detection of Grapevine fanleaf Virus (GFLV). In this study, recombinant GFLV coat protein gene related to selected antigenic determinants was inserted into pET-28a bacterial expression vector and the construct (pET-28a CP42) was cloned into E. coli strain (DE3). Expressed protein was verified with western blotting assay by the use of commercially available anti-GFLV antibody. The recombinant protein was purified using nickel-nitrilotriacetic acid (Ni-NTA) resin. Balb/c mice were immunized with purified protein and splenocytes of hyperimmunized mice were fused with murine myeloma Sp2/0 cells. Positive hybridomas were selected by ELISA using CP42 as coating antigen. The results showed that monoclonal antibody (MAb) specific to CP42 has been successfully generated. Efficiency of produced antibody was analyzed by ELISA and western blotting assay using some confirmed grapevine samples. The infection was confirmed previously based on morphological features and ELISA assay, performed using commercial anti-GFLV antibody. The monoclonal antibody reacted with antigen in ELISA and immunoblot method. Our results demonstrated that anti recombinant CP42 monoclonal antibodies are able to diagnose whole virus in infected grapevine sample using ELISA test.
[Extraction method suitable for detection of unheated crustaceans including cephalothorax by ELISA].
Shibahara, Yusuke; Yamada, Itta; Uesaka, Yoshihiko; Uneo, Noriko; Abe, Akihisa; Ohashi, Eiji; Shiomi, Kazuo
2009-08-01
When unheated whole samples of crustaceans (shrimp, prawn and crab) were analyzed with our ELISA kit (FA test EIA-Crustacean 'Nissui') using anti-tropomyosin antibodies, a remarkable reduction in reactivity was recognized. This reduction in activity was found to be due to the digestion of tropomyosin during the extraction process by proteases contained in cephalothorax. To avoid the digestion of tropomyosin by proteases, we developed an extraction method (heating method) suitable for the detection of tropomyosin in unheated crustaceans including cephalothorax. Experiments with unheated whole samples of various species of crustaceans confirmed that the heating method greatly improved the low reactivity in the standard method; the heating method gave extraction efficiencies of as high as 93-107%. Various processed crustaceans with cephalothorax, such as dry products (unheated or weakly heated products) and pickles in soy sauce (unheated products), that showed low reactivity with the standard method were confirmed to give superior results with the heating method. These results indicated that the developed heating method is suitable for detecting unheated crustaceans with cephalothorax by means of the ELISA kit.
Zhou, Lijun; Lv, Zhiqiang; Shao, Jing; Xu, Ying; Luo, Xiaohong; Zhang, Yuming; Hu, Yang; Zhang, Wenji; Luo, Shuhong; Fang, Jianmin; Wang, Ying; Duan, Chaohui; Huang, Ruopan
2016-09-01
The human epididymis protein 4 (HE4) may have high specificity in the detection of malignant diseases, making the development of an immunoassay for HE4 essential. In our study, a fusion gene was constructed encoded with the HE4 protein. This protein was then produced in the bacterial cells (Escherichia coli) and used to immunize mice in order to eventually generate hybridomas specific to HE4. The hybridoma supernatants were then screened, and four positive anti-HE4 cell lines were selected. These cell lines produce monoclonal antibodies against HE4 epitopes, as demonstrated in the Western blot as well as by direct enzyme-linked immunosorbent assay (ELISA). Using the developed antibodies, we successfully identified several good antibody pairs from the hybridomas, which allowed for the development of a sandwich ELISA to measure HE4 levels. By using the HE4 ELISA, we measured HE4 levels of 60 clinical human serum samples. Compared with the Food and Drug Administration (FDA) approved kit (Roche), our results showed a strong positive correlation to those of the FDA-approved kit. In summary, highly sensitive antibody pairs were screened against HE4, and a sandwich ELISA was developed as an accurate analytical tool for the detection of HE4 in human serum, which could be especially valuable for diagnosing ovarian carcinomas. © 2015 Wiley Periodicals, Inc.
Assessment of DNA extracted from FTA® cards for use on the Illumina iSelect BeadChip
McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F
2009-01-01
Background As FTA® cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes ≥ 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. Findings An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. Conclusion We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform. PMID:19531223
Assessment of DNA extracted from FTA cards for use on the Illumina iSelect BeadChip.
McClure, Matthew C; McKay, Stephanie D; Schnabel, Robert D; Taylor, Jeremy F
2009-06-16
As FTA cards provide an ideal medium for the field collection of DNA we sought to assess the quality of genomic DNA extracted from this source for use on the Illumina BovineSNP50 iSelect BeadChip which requires unbound, relatively intact (fragment sizes >or= 2 kb), and high-quality DNA. Bovine blood and nasal swab samples collected on FTA cards were extracted using the commercially available GenSolve kit with a minor modification. The call rate and concordance of genotypes from each sample were compared to those obtained from whole blood samples extracted by standard PCI extraction. An ANOVA analysis indicated no significant difference (P > 0.72) in BovineSNP50 genotype call rate between DNA extracted from FTA cards by the GenSolve kit or extracted from whole blood by PCI. Two sample t-tests demonstrated that the DNA extracted from the FTA cards produced genotype call and concordance rates that were not different to those produced by assaying DNA samples extracted by PCI from whole blood. We conclude that DNA extracted from FTA cards by the GenSolve kit is of sufficiently high quality to produce results comparable to those obtained from DNA extracted from whole blood when assayed by the Illumina iSelect technology. Additionally, we validate the use of nasal swabs as an alternative to venous blood or buccal samples from animal subjects for reliably producing high quality genotypes on this platform.
Optimization and Validation of ELISA for Pre-Clinical Trials of Influenza Vaccine.
Mitic, K; Muhandes, L; Minic, R; Petrusic, V; Zivkovic, I
2016-01-01
Testing of every new vaccine involves investigation of its immunogenicity, which is based on monitoring its ability to induce specific antibodies in animals. The fastest and most sensitive method used for this purpose is enzyme-linked immunosorbent assay (ELISA). However, commercial ELISA kits with whole influenza virus antigens are not available on the market, and it is therefore essential to establish an adequate assay for testing influenza virusspecific antibodies. We developed ELISA with whole influenza virus strains for the season 2011/2012 as antigens and validated it by checking its specificity, accuracy, linearity, range, precision, and sensitivity. The results show that we developed high-quality ELISA that can be used to test immunogenicity of newly produced seasonal or pandemic vaccines in mice. The pre-existence of validated ELISA enables shortening the time from the process of vaccine production to its use in patients, which is particularly important in the case of a pandemic.
Bodjo, Sanne Charles; Baziki, Jean-de-Dieu; Nwankpa, Nick; Chitsungo, Ethel; Koffi, Yao Mathurin; Couacy-Hymann, Emmanuel; Diop, Mariame; Gizaw, Daniel; Tajelser, Idris Badri Adam; Lelenta, Mamadou; Diallo, Adama; Tounkara, Karim
2018-07-01
Peste des petits ruminants (PPR) is a contagious and economically important disease affecting production of small ruminants (i.e., sheep and goats). Taking into consideration the lessons learnt from the Global Rinderpest Eradication Programme (GREP), PPR is now targeted by the international veterinary community as the next animal disease to be eradicated. To support the African continental programme for the control of PPR, the Pan African Veterinary Vaccine Centre of the African Union (AU-PANVAC) is developing diagnostics tools. Here, we describe the development of a blocking enzyme-linked immunosorbent assay (bELISA) that allows testing of a large number of samples for specific detection of antibodies directed against PPR virus in sheep and goat sera. The PPR bELISA uses an anti-haemagglutinin (H) monoclonal antibody (MAb) as a competitor antibody, and tests results are interpreted using the percentage of inhibition (PI) of MAb binding generated by the serum sample. PI values below or equal to 18% (PI ≤ 18%) are negative, PI values greater than or equal to 25% (PI ≥ 25%) are positive, and PI values greater than 18% and below 25% are doubtful. The diagnostic specificity (DSp) and diagnostic sensitivity (DSe) were found to be 100% and 93.74%, respectively. The H-based PPR-bELISA showed good correlation with the virus neutralization test (VNT), the gold standard test, with a kappa value of 0.947. The H-based PPR-bELISA is more specific than the commercial kit ID Screen® PPR Competition (N-based PPR-cELISA) from IDvet (France), but the commercial kit is slightly more sensitive than the H-based PPR-bELISA. The validation process also indicated good repeatability and reproducibility of the H-based PPR-bELISA, making this new test a suitable tool for the surveillance and sero-monitoring of the vaccination campaign.
Abdalla, E A; Weigel, K A; Byrem, T M; Rosa, G J M
2016-03-01
Bovine leukosis (BL) is a retroviral disease caused by the bovine leukosis virus (BLV), which affects only cattle. Dairy cows positive for BL produce less milk and have more days open than cows negative for BL. In addition, the virus also affects the immune system and causes weaker response to vaccines. Heritability estimates of BL incidence have been reported for Jersey and Holstein populations at about 0.08, indicating an important genetic component that can potentially be exploited to reduce the prevalence of the disease. However, before BL is used in selection programs, it is important to study its genetic associations with other economically important traits such that correlated responses to selection can be predicted. Hence, this study aimed to estimate the genetic correlations of BL with milk yield (MY) and with somatic cell score (SCS). Data of a commercial assay (ELISA) used to detect BLV antibodies in milk samples were obtained from Antel BioSystems (Lansing, MI). The data included continuous milk ELISA scores and binary milk ELISA results for 11,554 cows from 112 dairy herds across 16 US states. Continuous and binary milk ELISA were analyzed with linear and threshold models, respectively, together with MY and SCS using multitrait animal models. Genetic correlations (posterior means ± standard deviations) between BL incidence and MY were 0.17 ± 0.077 and 0.14 ± 0.076 using ELISA scores and results, respectively; with SCS, such estimates were 0.20 ± 0.081 and 0.17 ± 0.079, respectively. In summary, the results indicate that selection for higher MY may lead to increased BLV prevalence in dairy herds, but that the inclusion of BL (or SCS as an indicator trait) in selection indexes may help attenuate this problem. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
[Denaturation of egg antigens by cooking].
Watanabe, Hiroko; Akaboshi, Chie; Sekido, Haruko; Tanaka, Kouki; Tanaka, Kazuko; Shimojo, Naoki
2012-01-01
Changes in egg protein contents by cooking were measured with an ELISA kit using Tris-HCl buffer in model foods including cake, meatballs, pasta and pudding made with whole egg, egg-white and egg-yolk. The egg protein contents were lowest in the deep-fried model foods of cakes and meatballs. Ovalbumin (OVA) was undetectable (<1 µg/g) and ovomucoid (OVM) was lowest in pouched meatballs, suggesting that processing temperature and uniform heat-treatment affect the detection of egg protein. Furthermore, egg protein contents were below 6 µg/g in the pouched meatballs and pasta made with egg-yolk, and OVA and OVM were not detected by Western blotting analysis with human IgE from patients' serum. On the other hand, processed egg proteins were detected with an ELISA kit using a surfactant and reductant in the extract buffer.
Park, Sung Kwon; Lee, Myung Hoon; Cho, Soo Hyun
2014-01-01
This study was performed to develop a rapid immuno-assay kit, by using a specific antigen to detect Hanwoo brand meat. We selected a synthetic antigen specific to our target antibody, named BIO-TAG (Tyr-D-Ala-Phe), by utilizing a computer-based analysis and literature review. BIO-TAG tagged with adjuvant was subcutaneously injected in sheep and Hanwoo. The serum and meat juice of the immunized or non-immunized animal were then analyzed, to measure the titer of antibody by ELISA and Western blot. The amount of antibodies against the BIO-TAG increased (p<0.05) in serum by vaccination. Furthermore, meat juice from the immunized Hanwoo showed greater (p<0.05) antibody titer, compared with those from non-immunized groups. To optimze the dilution factor, we performed dot-ELISA, with various combination levels of BIO-TAG. Results from dot-ELISA showed that 2 mg/mL BIO-TAG was sufficient to distinguish the immunized meat from non-immunized groups. These results support our hypothesis that simple immunization of Hanwoo generates a sufficient amount of antibodies to be detectable in the meat juice by means of the immune-assay. Therefore, specific Hanwoo brand meat can be more precisely identified by our rapid diagnostic kit. This technology can deter possible fraud of counterfeit meat brands in the Korean domestic market with ease and rapidity; and offers a new tool that guarantees consumers high quality Hanwoo brand beef. PMID:26761175
Schnyder, Manuela; Deplazes, Peter
2012-11-13
Dirofilaria immitis and Angiostrongylus vasorum are both important potentially fatal canine nematodes with overlapping endemic areas, especially in Europe. The preadult and adult stages of both species are living in the Arteria pulmonalis and the right heart, and diagnostically detectable circulating parasite antigens have been demonstrated for both species. For the detection of D. immitis infections, a variety of commercial tests have been developed, however, they have not been evaluated for cross-reactions against circulating antigens of A. vasorum. In this study, potential cross-reactions of sera from 16 dogs, which were experimentally infected with A. vasorum and which had circulating antigens as confirmed by a species-specific ELISA, were evaluated for the detection of A. vasorum antigen in six commercially available D. immitis test kits. In three fast tests (Witness® Dirofilaria, SensPERT® Canine Heartworm, SNAP® 4Dx® Plus), all sera were negative. One fast membrane ELISA (SNAP® HTWM RT Test) was positive with four sera (25%), and one serum delivered a non-valid result twice. In the PetChek® HTWM PF Test, depending on the interpretation protocol, 5 or 8 dogs (31.2 - 50%) were positive. With the DiroCHEK®-ELISA, a single A. vasorum-infected dog (6.2%) tested positive. Due to potential cross-reactions with A. vasorum in commercially available test kits for the detection of D. immitis antigen, the simultaneous use of highly specific diagnostic methods for the differentiation of these two canine heart worms is recommended.
Development of a novel protein chip for the detection of bluetongue virus in China.
Xu, Q Y; Sun, E C; Feng, Y F; Li, J P; Lv, S; Zhang, Q; Wang, H X; Zhang, J K; Wu, D L
2016-08-01
Bluetongue (BT), which is caused by the BT virus (BTV), is an important disease in ruminants that leads to significant economic losses in the husbandry industry. To detect BTV-specific antibodies in serum, a protein chip detection method based on a novel solid supporting material known as polymer-coated initiator-integrated poly (dimethyl siloxane) (iPDMS) was developed. With a threshold of 25% (signal-to-noise percentage), the sensitivity and specificity of the protein chip were 98.6% and 94.8%, respectively. Furthermore, spot serum samples obtained from six provinces of China were tested with the protein chip and a commercially available BTV enzyme-linked immunosorbent assay (ELISA) kit (IDEXX). Of 615 samples, BTV-specific antibodies were detected in 200 (32.52%) by the protein chip and in 176 (28.62%) by the IDEXX BTV ELISA kit. Comparison of the protein chip with the commercial IDEXX BTV ELISA kit yielded the following spot serum detection results: a total coincidence, a negative coincidence and a positive coincidence of 95.12%, 99.28% and 86.5%, respectively. With the protein chip, the BTV-specific serum antibody was detected in samples from all six provinces, and the positive rates ranged from 4.12 to 74.4%. These results indicate that this protein chip detection method based on iPDMS is useful for the serological diagnosis of BTV infection and for epidemiological investigation. Copyright © 2016. Published by Elsevier B.V.
Evaluation of ethanol vortex ELISA for detection of bovine tuberculosis in cattle and deer.
Wadhwa, Ashutosh; Johonson, Rachel E; Eda, Keiko; Waters, W Ray; Palmer, Mitchell V; Bannantine, John P; Eda, Shigetoshi
2014-07-04
The use of serological assays for diagnosis of bovine tuberculosis (TB) has been intensively studied and use of specific antigens have aided in improving the diagnostic accuracy of the assays. In the present study, we report an in-house enzyme linked immunosorbent assay (ELISA), developed by using ethanol extract of Mycobacterium bovis (M. bovis). The assay, named (ethanol vortex ELISA [EVELISA]), was evaluated for detection of anti- M. bovis antibodies in the sera of cattle and white-tailed deer. By using the EVELISA, we tested sera obtained from two species of animals; cattle (n = 62 [uninfected, n = 40; naturally infected, n = 22]) and white-tailed deer (n = 41 [uninfected, n = 25; naturally infected, n = 7; experimentally infected, n = 9]). To detect species specific molecules, components in the ethanol extract were analyzed by thin layer chromatography and western blotting. Among the tested animals, 77.2% of infected cattle and 87.5% of infected deer tested positive for anti- M. bovis antibody. There were only minor false positive reactions (7.5% in cattle and 0% in deer) in uninfected animals. M. bovis -specific lipids and protein (MPB83) in the ethanol extract were detected by thin layer chromatography and western blotting, respectively. The results warrant further evaluation and validation of EVELISA for bovine TB diagnosis of traditional and alternative livestock as well as for free-ranging animal species.
Aragaw, Kassaye; Sibhat, Berhanu; Ayelet, Gelagay; Skjerve, Eystein; Gebremedhin, Endrias Z; Asmare, Kassahun
2018-05-31
This work was conducted to estimate the seroprevalence, to identify potential factors that influence seroprevalence of bovine viral diarrhea virus (BVDV), and to investigate the association between BVDV serostatus and occurrence of reproductive disorders in dairy cattle in three milksheds in Ethiopia. A total of 1379 serum samples were obtained from cattle randomly selected from 149 herds from three milksheds representing central, southern, and western Ethiopia. Sera samples were examined for bovine viral diarrhea virus (BVDV) antibodies using commercial competitive enzyme-linked immunosorbent assay (ELISA) kit. Logistic regression analysis was employed to investigate associations between risk factors and the risk of BVDV seroprevalence, and BVDV serostatus and reproductive disorders. Seroreaction to BVDV antigens was detected in 32.6% of the 1379 cattle and 69.8% of the 149 herds sampled. Factors associated with BVDV seroplevalence were age, breed, and herd size (P < 0.05). Adult cattle ≥ 18 months old had 2.1 (95% CI 1.5, 3.1) times the odds of BVDV seroreaction than younger cattle. Holstein-Friesian (HF) local crosses (OR = 2.1, 95% CI 1.3, 3.4) and HFs (OR = 1.3, 95% CI 0.9, 1.9) were more likely to be seropositive than Jersey and the odds of seropositivity in cattle in large herds with 11 or more animals were higher (OR = 1.8, 95% CI 1.3, 2.5) than the odds of BVDV seropositivity in smaller herds. Seroprevalence was not associated with geographical region (P > 0.05). Risk of reproductive disorders was not affected by BVDV serostatus, except for repeat breeding (P > 0.05). The present study demonstrated that BVDV has wide distribution in the country being detected in all the 15 conurbations and 69.8% of herds involved in the study.
Castillo, Daniela S.
2017-01-01
Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention. PMID:28759641
Castillo, Daniela S; Cassola, Alejandro
2017-01-01
Cow milk protein allergy (CMPA) is the most common childhood food allergy, which can sometimes persist or can newly develop in adulthood with severe symptoms. CMPA's treatment is complete dietary avoidance of milk proteins. To achieve this task, patients have to be aware of milk proteins found as "hidden allergens" in food commodities. In regard to milk proteins, it has been reported that allergenicity of caseins remains unaffected upon heat treatment. For these reasons, we aimed to obtain monoclonal antibodies (mAbs) against native and denatured β-casein, one of the most abundant and antigenic caseins, in order to develop an indirect competitive ELISA (icELISA) to detect and quantify traces of this milk allergen in raw and processed foodstuffs. We developed two specific hybridoma clones, 1H3 and 6A12, which recognized β-casein in its denatured and native conformations by indirect ELISA (iELISA). Cross-reaction analysis by Western blot and iELISA indicated that these mAbs specifically recognized β-casein from bovine and goat milk extracts, while they did not cross-react with proteins present in other food matrixes. These highly specific mAbs enabled the development of sensitive, reliable and reproducible icELISAs to detect and quantify this milk protein allergen in food commodities. The extraction of β-casein from foodstuff was efficiently carried out at 60°C for 15 minutes, using an extraction buffer containing 1% SDS. The present study establishes a valid 1H3 based-icELISA, which allows the detection and quantification -0.29 ppm and 0.80 ppm, respectively- of small amounts of β-casein in raw and processed foods. Furthermore, we were able to detect milk contamination in incurred food samples with the same sensitivity as a commercial sandwich ELISA thus showing that this icELISA constitutes a reliable analytical method for control strategies in food industry and allergy prevention.
García-Lunar, P; Moré, G; Campero, L; Ortega-Mora, L M; Álvarez-García, G
2015-11-30
Bovine besnoitiosis control remains a challenge because the disease continues to spread and control relies solely on accurate diagnosis coupled to management measures. However, recent studies have reported that routinely used ELISAs may raise a high number of false-positive results. Herein, cross-reactions between Besnoitia besnoiti antigens and anti-Neospora caninum and/or anti-Sarcocystis spp.-specific antibodies were studied in an in house ELISA since N. caninum and Sarcocystis spp. are closely related parasites, and both infections are highly prevalent in cattle worldwide. The serum panel was composed of the following categories: sera from B. besnoiti-seronegative (n=75) and -seropositive cattle (n=66), B. besnoiti-based-ELISA false-positive reactors (n=96) together with N. caninum (n=36) and Sarcocystis spp. (n=42) -seropositive reference cattle sera. B. besnoiti tachyzoite based western blot (WB) results classified animals as seropositive or seronegative. Sera were analyzed for the detection of anti-N. caninum by WB and ELISA and anti-Sarcocystis spp.-specific antibodies by WB and IFAT. Those samples recognizing a Sarcocystis spp. 18-20 kDa antigenic region and N. caninum 17-18 kDa immunodominant antigen were considered to be Sarcocystis spp. and N. caninum seropositive, respectively. The category of B. besnoiti based-ELISA false-positive reactors showed the highest number of sera with specific anti-Sarcocystis spp. and anti-N. caninum antibodies (74%; 71/96), followed by the N. caninum-seropositive cattle category (52.8%; 19/36). In contrast, few B. besnoiti-seronegative and -seropositive cattle showed antibodies against Sarcocystis spp. and N. caninum (10.7%; 8/75 and 1.5%; 1/66), respectively). This study revealed that B. besnoiti false-positive ELISA results were associated not only with the presence of anti-N. caninum and anti-Sarcocystis spp. antibodies (χ(2): 78.36; p<0.0001; OR: 34.6; CI: 14-88) but also with high antibody levels against them using ELISA and IFAT tests, respectively (p<0.05; t-test). These results may explain why only some animals seropositive to Sarcocystis spp. and/or N. caninum are Besnoitia false-positive reactors. Therefore, sera meeting these requirements should be included in future validations of serological tests for bovine besnoitiosis. Copyright © 2015 Elsevier B.V. All rights reserved.
Jin, Wanchun; Yamada, Keiko; Ikami, Mai; Kaji, Noritada; Tokeshi, Manabu; Atsumi, Yusuke; Mizutani, Makoto; Murai, Atsushi; Okamoto, Akira; Namikawa, Takao; Baba, Yoshinobu; Ohta, Michio
2013-03-01
Staphylococcal enterotoxins (SEs), produced by Staphylococcus aureus, are a major cause of staphylococcal food poisoning. Traditionally, sandwich enzyme-linked immunosorbent assay (ELISA) and reverse passive latex agglutination with rabbit antibody IgG have been used to detect SEs. However, most of these kits require a long processing time and there is a risk of false-positive results since IgG reacts nonspecifically with protein A produced by S. aureus. In this study, we prepared antienterotoxin chicken IgY antibodies specific for each SE (SEA to SEE) without reaction to protein A, which enabled a drastic reduction in nonspecific reactions. ELISAs, lateral flow device (LFDs), and IgY-based immunopillar chips were developed for SE detection. All the ELISAs developed were as sensitive as commercially available kits. The SEs in milk were successfully detected by the ELISAs, LFDs, and immunopillar chips without any sample pretreatment. The LFD could detect SEA even at the low concentration of 0.2 ng/ml within 15 min in milk. The detection limit of the immunopillar chips for the SEs ranged from 0.01 to 0.1 ng/ml in milk; the SEs were detected within 12 min and specialized skills were not required. The ELISA and LFD detected SEA in dairy products artificially contaminated with S. aureus, including ice cream, yogurt, and café au lait, in a dose-dependent manner. In conclusion, IgY allows highly specific detection of SEs, and ELISAs, LFDs, and immunopillar chips should be useful tools for screening SEs in milk and dairy products. Copyright © 2013 Elsevier B.V. All rights reserved.
Optofluidic laser for dual-mode sensitive biomolecular detection with a large dynamic range
NASA Astrophysics Data System (ADS)
Wu, Xiang; Oo, Maung Kyaw Khaing; Reddy, Karthik; Chen, Qiushu; Sun, Yuze; Fan, Xudong
2014-04-01
Enzyme-linked immunosorbent assay (ELISA) is a powerful method for biomolecular analysis. The traditional ELISA employing light intensity as the sensing signal often encounters large background arising from non-specific bindings, material autofluorescence and leakage of excitation light, which deteriorates its detection limit and dynamic range. Here we develop the optofluidic laser-based ELISA, where ELISA occurs inside a laser cavity. The laser onset time is used as the sensing signal, which is inversely proportional to the enzyme concentration and hence the analyte concentration inside the cavity. We first elucidate the principle of the optofluidic laser-based ELISA, and then characterize the optofluidic laser performance. Finally, we present the dual-mode detection of interleukin-6 using commercial ELISA kits, where the sensing signals are simultaneously obtained by the traditional and the optofluidic laser-based ELISA, showing a detection limit of 1 fg ml-1 (38 aM) and a dynamic range of 6 orders of magnitude.
Diagnostic gap in Bovine viral diarrhea virus serology during the periparturient period in cattle.
Bachofen, Claudia; Bollinger, Barbara; Peterhans, Ernst; Stalder, Hanspeter; Schweizer, Matthias
2013-09-01
Detection of antibodies against Bovine viral diarrhea virus (BVDV) in serum and milk by enzyme-linked immunosorbent assay (ELISA) is a crucial part of all ongoing national schemes to eradicate this important cattle pathogen. Serum and milk are regarded as equally suited for antibody measurement. However, when retesting a seropositive cow 1 day after calving, the serum was negative in 6 out of 9 different ELISAs. To further investigate this diagnostic gap around parturition, pre- and postcalving serum and milk samples of 5 cows were analyzed by BVDV antibody ELISA and serum neutralization test (SNT). By ELISA, 3 out of the 5 animals showed a diagnostic gap in the serum for up to 12 days around calving but all animals remained positive in SNT. In milk, the ELISA was strongly positive after birth but antibody levels decreased considerably within the next few days. Because of the immunoglobulin G (IgG)1-specific transport of serum antibodies into the mammary gland for colostrum production, the IgG subclass specificity of the total and the BVDV-specific antibodies were determined. Although all 5 animals showed a clear decrease in the total and BVDV-specific IgG1 antibody levels at parturition, the precalving IgG1-to-IgG2 ratios of the BVDV-specific antibodies were considerably lower in animals that showed the diagnostic gap. Results showed that BVDV seropositive cows may become "false" negative in several ELISAs in the periparturient period and suggest that the occurrence of this diagnostic gap is influenced by the BVDV-specific IgG subclass response of the individual animal.
Shafee, Muhammad; Rabbani, Masood; Sheikh, Ali Ahmad; Ahmad, Mansoor Din; Razzaq, Abdul
2011-01-24
A total of 200 milk samples from cattle (n = 86) and buffalo (n = 114) were evaluated using milk ring test (MRT) and indirect enzyme-linked immunosorbent assay (i-ELISA). The overall prevalence was found to be 3% and 8.5% in cattle and buffaloes using MRT and i-ELISA, respectively. The prevalence was 4.6% and 1.7% in cattle and buffalo using MRT, respectively, while i-ELISA exhibited 20% and 0% in cattle and buffalo, respectively. The prevalence was higher in government dairy farm, compared to privately owned dairy farm. This paper points out an alarming situation in the target area with respect to the public health significance.
Shafee, Muhammad; Rabbani, Masood; Sheikh, Ali Ahmad; Ahmad, Mansoor din; Razzaq, Abdul
2011-01-01
A total of 200 milk samples from cattle (n = 86) and buffalo (n = 114) were evaluated using milk ring test (MRT) and indirect enzyme-linked immunosorbent assay (i-ELISA). The overall prevalence was found to be 3% and 8.5% in cattle and buffaloes using MRT and i-ELISA, respectively. The prevalence was 4.6% and 1.7% in cattle and buffalo using MRT, respectively, while i-ELISA exhibited 20% and 0% in cattle and buffalo, respectively. The prevalence was higher in government dairy farm, compared to privately owned dairy farm. This paper points out an alarming situation in the target area with respect to the public health significance. PMID:21331157
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Gabriël, Sarah
2016-08-30
The monoclonal antibody-based circulating antigen detecting ELISA (B158/B60 Ag-ELISA) has been used elaborately in several studies for the diagnosis of human, bovine and porcine cysticercosis. Interpretation of test results requires a good knowledge of the test characteristics, including the repeatability and the effect of the borders of the ELISA plates. Repeatability was tested for 4 antigen-negative and 5 antigen-positive reference bovine serum samples by calculating the Percentage Coefficient of Variation (%CV) within and between plates, within and between runs, overall, for two batches of monoclonal antibodies and by 2 laboratory technicians. All CV values obtained were below 20% (except one: 24.45%), which indicates a good repeatability and a negligible technician error. The value of 24.45% for indicating the variability between batches of monoclonal antibodies for one positive sample is still acceptable for repeatability measures. Border effects were determined by calculating the %CV values between the inner and outer wells of one plate for 2 positive serum samples. Variability is a little more present in the outer wells but this effect is very small and no significant border effect was found. Copyright © 2016 Elsevier B.V. All rights reserved.
Fablet, C; Rose, N; Bernard, C; Messager, I; Piel, Y; Grasland, B
2017-11-01
This study was designed to assess the diagnostic characteristics of two PCV2 ELISAs without a gold standard. Four hundred and sixty-five serum samples from finishing pigs (25 herds) not vaccinated against PCV2 were used. Samples were tested by two ELISAs: an in-house ELISA (I-ELISA) and the commercial SERELISA ® PCV2 Ab Mono Blocking kit (S-ELISA). A ROC curve was used to assess the S-ELISA's optimal threshold by taking the I-ELISA as a reference and using the cut-off previously determined by comparison to an cccmonolayer assay (IPMA). This led to an S-ELISA result ≥170 being considered as positive. The sensitivity (Se) and specificity (Sp) of each ELISA were then estimated without a gold standard using a Bayesian approach. The mean Se and Sp values of the I-ELISA were slightly higher than those of the S-ELISA (mean Se I-ELISA=0.90 vs. mean Se S-ELISA=0.86; mean Sp I-ELISA=0.92 vs. mean Sp S-ELISA=0.85). However, the 95% credibility intervals (CI95%) overlapped (Se I-ELISA CI95%=0.85-0.95 vs. Se S-ELISA CI95%=0.82-0.90; Sp I-ELISA CI95%=0.82-0.98 vs. Sp S-ELISA CI95%=0.75-0.94). Both ELISAs appeared to be valuable tools for detecting PCV2 antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
VARGAS, Catalina; TORRES, Patricio; JERCIC, María Isabel; LOBOS, Marta; OYARCE, Alan; MIRANDA, Juan Carlos; AYALA, Salvador
2016-01-01
SUMMARY The frequency of anti-Toxocara spp. antibodies in individuals attended by the Centro de Salud Familiar in the coastal Niebla town, Chile, was related to the host and to environmental factors. IgG anti- Toxocara antibodies were detected with a commercial ELISA kit (SCIMEDX Corporation, USA). Samples with undetermined absorbance values were subjected to an additional ELISA standardized by the Instituto de Salud Pública, Chilean Health Ministry, a commercial ELISA (NOVATEC, Germany), and a commercial Western blot kit (LDBio Diagnostics, France). Hematological exams were performed using an automated blood counter and blood smears. Dog feces were collected from the ground along the main road in Niebla, including rural and urban locations. Ninety (25.4%) of the 355 examined individuals were positive by the ELISA test. The frequency of anti-Toxocara antibodies and the infection risk were significantly higher (p < 0.05) among those individuals ≥ 40 years old with respect to the 20-39 years old group, in individuals from rural locations, those who did not have a safe drinking water supply in the house or who presented blood eosinophilia. The proportion of positive samples of dog feces and the mean number of Toxocara canis eggs/g of feces in urban and rural areas were similar (p > 0.05). PMID:27680167
Vargas, Catalina; Torres, Patricio; Jercic, María Isabel; Lobos, Marta; Oyarce, Alan; Miranda, Juan Carlos; Ayala, Salvador
2016-09-22
The frequency of anti-Toxocara spp. antibodies in individuals attended by the Centro de Salud Familiar in the coastal Niebla town, Chile, was related to the host and to environmental factors. IgG anti- Toxocara antibodies were detected with a commercial ELISA kit (SCIMEDX Corporation, USA). Samples with undetermined absorbance values were subjected to an additional ELISA standardized by the Instituto de Salud Pública, Chilean Health Ministry, a commercial ELISA (NOVATEC, Germany), and a commercial Western blot kit (LDBio Diagnostics, France). Hematological exams were performed using an automated blood counter and blood smears. Dog feces were collected from the ground along the main road in Niebla, including rural and urban locations. Ninety (25.4%) of the 355 examined individuals were positive by the ELISA test. The frequency of anti-Toxocara antibodies and the infection risk were significantly higher (p < 0.05) among those individuals ≥ 40 years old with respect to the 20-39 years old group, in individuals from rural locations, those who did not have a safe drinking water supply in the house or who presented blood eosinophilia. The proportion of positive samples of dog feces and the mean number of Toxocara canis eggs/g of feces in urban and rural areas were similar (p > 0.05).
Kim, Eun-Ju; Cheong, Kwang-Myun; Joung, Ha-Kyung; Kim, Bo-Hye; Song, Jae-Young; Cho, In-Soo; Lee, Kyoung-Ki; Shin, Yeun-Kyung
2016-12-30
Infection of cattle with bovine leukemia virus (BLV) has been observed and reported worldwide, including in Korea. The onsite identification of infected cattle would help decreasing and eradicating BLV infections on farms. Here, we present a new immunochromatographic assay that employs monoclonal antibodies (MAbs) for the detection of antibodies against BLV in the field. BLV envelope glycoprotein (gp)51 was expressed in E. coli , and MAbs against recombinant BLV gp51 were generated for the development of an immunochromatographic assay to detect BLV antibodies in cattle. The sensitivity and specificity of the assay were determined by comparing these results with those obtained from a standard enzyme linked immunosorbent assay (ELISA). A total of 160 bovine sera were used to evaluate the new immunochromatographic assay. Using ELISA as a reference standard, the relative specificity and sensitivity of this assay were determined to be 94.7% and 98%, respectively. Because of its high sensitivity and specificity, this BLV antibody detection assay would be suitable for the onsite identification of BLV infection in the field.
Walsh, Robert B.; Kelton, David F.; Hietala, Sharon K.; Duffield, Todd F.
2013-01-01
Serum and milk samples from 1229 cows on 22 Ontario dairy farms were individually tested for antibodies specific for bovine leukosis virus (BLV) and Neospora caninum by enzyme-linked immunosorbent assay (ELISA). Antibodies against BLV were present in 361 serum samples (29.4%) and 369 milk samples (30.0%). Comparing the 2 tests, agreement was almost perfect (k = 0.86; 95% CI = 0.83 to 0.90) and the proportions of samples positive were not significantly different (P = 0.56). Both tests identified the same 3 herds free of bovine leukosis virus. Antibodies against N. caninum were detected in 138 serum samples (11.2%), and 111 milk samples (9.0%). Agreement between the 2 tests was moderate (k = 0.52; 95% CI = 0.43 to 0.59). Four herds were free of neosporosis by the serum test, while 10 herds were negative by the milk test. The ELISA on milk samples facilitates sample collection to classify herds free of BLV; the milk N. caninum ELISA was less reliable in predicting herd-level infection. PMID:24082160
Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun
2016-11-25
Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.
Chen, Mu-Xin; Chen, Jia-Xu; Chen, Shao-Hong; Huang, Da-Na; Ai, Lin; Zhang, Ren-Li
2016-01-01
Angiostrongyliasis is difficult to be diagnosed for the reason that no ideal method can be used. Serologic tests require specific equipment and are not always available in poverty-stricken zone and are time-consuming. A lateral flow immunoassay (LFIA) may be useful for angiostrongyliasis control. We established a LFIA for the diagnosis of angiostrongyliasis based on 2 monoclonal antibodies (mAbs) against antigens of Angiostrongylus cantonensis adults. The sensitivity and specificity were 91.1% and 100% in LFIA, while those of commercial ELISA kit was 97.8% and 86.3%, respectively. Youden index was 0.91 in LFIA and 0.84 in commercial ELISA kit. LFIA showed detection limit of 1 ng/ml of A. cantonensis ES antigens. This LFIA was simple, rapid, highly sensitive and specific, which opened an alternative approach for the diagnosis of human angiostrongyliasis. PMID:27417097
Development of a sandwich ELISA for the quantification of enterovirus 71.
Ma, Shujun; Mao, Qunying; Liang, Zhenglun; Zhang, Cuijuan; Yang, Wenxing; Sun, Zhe; Zhang, Haijiang; Shen, Xinliang; Bi, Shengli; Sun, Le
2014-05-01
Since 2008, enterovirus 71 (EV71) has been responsible for high-mortality seasonal epidemics of hand, foot and mouth disease in China. Currently many groups in the world are in the process of developing EV71 vaccines to combat this deadly disease. We have developed three EV71-specific monoclonal antibodies, and in this study we report the establishment of a fast and cost-effective sandwich ELISA kit for measurement of virus concentration in EV71 vaccines using a pair of mouse anti-EV71 monoclonal antibodies. The system is specific for EV71 virus, with no cross-reactivity to coxsackievirus A16, H1N1, rabies, and hepatitis A. Using a reference EV71 vaccine standard, the sensitivity of the assay kit was determined to be 0.82 U/ml, with a linear range between 3.75 and 120 U/ml.
Evaluation of Five Antibody Detection Tests for Diagnosis of Bovine Paratuberculosis
Collins, Michael T.; Wells, Scott J.; Petrini, Kristine R.; Collins, James E.; Schultz, Ronald D.; Whitlock, Robert H.
2005-01-01
Five diagnostic tests based on enzyme-linked immunosorbent assay (ELISA) technology for bovine paratuberculosis were evaluated by using individual serum or milk samples from 359 dairy cattle in seven paratuberculosis-free herds and 2,094 dairy cattle in seven Mycobacterium paratuberculosis-infected dairy herds. Three independent laboratories using three different culture procedures completed fecal cultures for M. paratuberculosis on these cattle and found 417 cows to be shedding M. paratuberculosis in their feces. An animal that was fecal culture positive for M. paratuberculosis by any of the three laboratories was considered a confirmed case of infection. The specificity of three ELISAs (two on serum and one on milk) was ≥99.8%. The specificity of the remaining two ELISAs, both done on serum, was 94.9 and 84.7%. Four of the five ELISAs evaluated produced similar sensitivity in detecting fecal culture-positive cattle (27.8 to 28.9%). Serum ELISA “D” had the lowest specificity (84.7%) and the highest sensitivity (44.5%), but if the cutoff value defining a positive test was changed from 125 to 250% (of the positive control) the sensitivity and specificity, 31.8 and 97.5%, respectively, were comparable to those of the other four assays. If the case definition for M. paratuberculosis infection was based on the culture results of a single laboratory instead of the combined results of three laboratories, ELISA sensitivity estimates were 45.7 to 50.0%. With the exception of ELISA D, assay agreement was high (kappa 0.66 to 0.85) for categorical assay interpretations (positive or negative), but linear regression of quantitative results showed low correlation coefficients (r2 = 0.40 to 0.68) due to the fact that ELISA results for some cows were high in one assay but low in another assay. Likelihood ratio analysis showed a direct relationship between the magnitude of ELISA result and the odds of a cow shedding M. paratuberculosis in its feces. If used judiciously and interpreted quantitatively, these ELISAs are useful tools in support of paratuberculosis control programs in dairy herds. PMID:15939741
Negash, Markos; Kassu, Afework; Amare, Bemnet; Yismaw, Gizachew; Moges, Beyene
2018-01-01
Helicobacter pylori antibody titters fall very slowly even after successful treatment. Therefore, tests detecting H. pylori antibody lack specificity and sensitivity. On the other hand, H. pylori stool antigen tests are reported as an alternative assay because of their reliability and simplicity. However, the comparative performance of H. pylori stool antigen tests for detecting the presence of the bacterium in clinical specimens in the study area is not assessed. Therefore, in this study we evaluated the performance of SD BIOLINE H. pylori Ag rapid test with reference to the commercially available EZ- STEP ELISA and SD BIOLINE H. pylori Ag ELISA tests. Stool samples were collected to analyse the diagnostic performance of SD BIOLINE H. pylori Ag rapid test kit using SD H. pylori Ag ELISA kit and EZ- STEP ELISA tests as a gold standard. Serum samples were also collected from each patient to test for the presence of H. pylori antibodies using dBest H. pylori Test Disk. Sensitivity, specificity, predictive values and kappa value are assessed. P values < 0.05 were taken statistically significant. Stool and serum samples were collected from 201 dyspeptic patients and analysed. The sensitivity, specificity, positive and negative predictive values of the SD BIOLINE H. pylori Ag rapid test were: 95.6% (95% CI, 88.8-98.8), 92.5% (95%CI, 89-94.1%), 86.7% (95% CI, 80.5-89.6), and 97.6% (95% CI, 993.9-99.3) respectively. The performance of SD BIOLINE H. pylori Ag rapid test was better than the currently available antibody test in study area. Therefore, the SD BIOLINE Ag rapid stool test could replace and be used to diagnose active H. pylori infection before the commencement of therapy among dyspeptic patients.
Şimşek, Ece; Aydemir, Esra Arslan; İmir, Nilüfer; Koçak, Orhan; Kuruoğlu, Aykut; Fışkın, Kayahan
2015-10-01
Dimethyl sulfoxide (DMSO) is widely used in biological research as a general solvent. While it has been previously demonstrated that DMSO possesses a wide range of pharmacological effects, there is no published work regarding the effects of DMSO on pro-angiogenic factor levels. This study was designed to investigate the possible effects of DMSO on the levels of three pro-angiogenic factors released from HeLa cells in vitro. Cells were treated with two different and previously determined concentrations of DMSO. The cytotoxic effects of DMSO concentrations on HeLa cells were determined via MTT. Survival rates of DMSO-treated cells were determined by Invitrogen live/dead viability/cytotoxicity kit and trypan blue exclusion assay. Changes in the pro-angiogenic levels in media were evaluated by Cayman's Substance P Enzyme Immunoassay ELISA kit. Vascular endothelial growth factor ELISA kit and interferon gamma ELISA kit for substance P, VEGF and IFNγ respectively. Changes in substance P levels were corrected by standard western blotting. Changes in VEGF and IFNγ levels were corrected both by western blot and real time PCR. Treatment with 1.4 μM DMSO caused a time-dependent inhibition of cell proliferation at 24, 48 and 72 h. 1.4 μM DMSO caused a significant reduction in VEGF levels at 72 h of incubation and sharp increases in IFNγ levels at both 48 and 72 h of incubation. According to real time PCR analyses, DMSO (1.4 μM) exhibited an inhibitory effect on VEGF but acted as an augmenter of IFNγ release on HeLa cells in vitro. This is the first report showing that the general solvent DMSO suppressed HeLa cell proliferation, decreased the levels of two pro-angiogenic factors (substance P and VEGF) and increased the release of an anti-angiogenic factor IFNγ in vitro. Copyright © 2015 Elsevier Ltd. All rights reserved.
Peyraud, Armelle; Poumarat, François; Tardy, Florence; Manso-Silván, Lucía; Hamroev, Karomatullo; Tilloev, Tillo; Amirbekov, Mullojon; Tounkara, Karim; Bodjo, Charles; Wesonga, Hezron; Nkando, Isabel Gacheri; Jenberie, Shiferaw; Yami, Martha; Cardinale, Eric; Meenowa, Deodass; Jaumally, Mahmad Reshad; Yaqub, Tahir; Shabbir, Muhammad Zubair; Mukhtar, Nadia; Halimi, Mohibullah; Ziay, Ghulam Mohammad; Schauwers, Willy; Noori, Hafizullah; Rajabi, Ali Madad; Ostrowski, Stéphane; Thiaucourt, François
2014-02-24
Few serological tests are available for detecting antibodies against Mycoplasma capricolum subsp. capripneumoniae, the causal agent of contagious caprine pleuropneumonia (CCPP). The complement fixation test, the test prescribed for international trade purposes, uses a crude antigen that cross-reacts with all the other mycoplasma species of the "mycoides cluster" frequently infecting goat herds. The lack of a more specific test has been a real obstacle to the evaluation of the prevalence and economic impact of CCPP worldwide. A new competitive ELISA kit for CCPP, based on a previous blocking ELISA, was formatted at CIRAD and used to evaluate the prevalence of CCPP in some regions of Kenya, Ethiopia, Mauritius, Tajikistan and Pakistan in an international collaborative study. The strict specificity of the test was confirmed in CCPP-free goat herds exposed to other mycoplasma species of the "mycoides cluster". Prevalence studies were performed across the enzootic range of the disease in Africa and Asia. Seroprevalence was estimated at 14.6% in the Afar region of Ethiopia, whereas all the herds presented for CCPP vaccination in Kenya tested positive (individual seroprevalence varied from 6 to 90% within each herd). In Mauritius, where CCPP emerged in 2009, nine of 62 herds tested positive. In Central Asia, where the disease was confirmed only recently, no positive animals were detected in the Wakhan District of Afghanistan or across the border in neighboring areas of Tajikistan, whereas seroprevalence varied between 2.7% and 44.2% in the other districts investigated and in northern Pakistan. The test was also used to monitor seroconversion in vaccinated animals. This newly formatted CCPP cELISA kit has retained the high specificity of the original kit. It can therefore be used to evaluate the prevalence of CCPP in countries or regions without vaccination programs. It could also be used to monitor the efficacy of vaccination campaigns as high-quality vaccines induce high rates of seroconversion.
2014-01-01
Background Few serological tests are available for detecting antibodies against Mycoplasma capricolum subsp. capripneumoniae, the causal agent of contagious caprine pleuropneumonia (CCPP). The complement fixation test, the test prescribed for international trade purposes, uses a crude antigen that cross-reacts with all the other mycoplasma species of the “mycoides cluster” frequently infecting goat herds. The lack of a more specific test has been a real obstacle to the evaluation of the prevalence and economic impact of CCPP worldwide. A new competitive ELISA kit for CCPP, based on a previous blocking ELISA, was formatted at CIRAD and used to evaluate the prevalence of CCPP in some regions of Kenya, Ethiopia, Mauritius, Tajikistan and Pakistan in an international collaborative study. Results The strict specificity of the test was confirmed in CCPP-free goat herds exposed to other mycoplasma species of the “mycoides cluster”. Prevalence studies were performed across the enzootic range of the disease in Africa and Asia. Seroprevalence was estimated at 14.6% in the Afar region of Ethiopia, whereas all the herds presented for CCPP vaccination in Kenya tested positive (individual seroprevalence varied from 6 to 90% within each herd). In Mauritius, where CCPP emerged in 2009, nine of 62 herds tested positive. In Central Asia, where the disease was confirmed only recently, no positive animals were detected in the Wakhan District of Afghanistan or across the border in neighboring areas of Tajikistan, whereas seroprevalence varied between 2.7% and 44.2% in the other districts investigated and in northern Pakistan. The test was also used to monitor seroconversion in vaccinated animals. Conclusions This newly formatted CCPP cELISA kit has retained the high specificity of the original kit. It can therefore be used to evaluate the prevalence of CCPP in countries or regions without vaccination programs. It could also be used to monitor the efficacy of vaccination campaigns as high-quality vaccines induce high rates of seroconversion. PMID:24565080
2012-01-01
Background Dirofilaria immitis and Angiostrongylus vasorum are both important potentially fatal canine nematodes with overlapping endemic areas, especially in Europe. The preadult and adult stages of both species are living in the Arteria pulmonalis and the right heart, and diagnostically detectable circulating parasite antigens have been demonstrated for both species. For the detection of D. immitis infections, a variety of commercial tests have been developed, however, they have not been evaluated for cross-reactions against circulating antigens of A. vasorum. Methods In this study, potential cross-reactions of sera from 16 dogs, which were experimentally infected with A. vasorum and which had circulating antigens as confirmed by a species-specific ELISA, were evaluated for the detection of A. vasorum antigen in six commercially available D. immitis test kits. Results In three fast tests (Witness® Dirofilaria, SensPERT® Canine Heartworm, SNAP® 4Dx® Plus), all sera were negative. One fast membrane ELISA (SNAP® HTWM RT Test) was positive with four sera (25%), and one serum delivered a non-valid result twice. In the PetChek® HTWM PF Test, depending on the interpretation protocol, 5 or 8 dogs (31.2 – 50%) were positive. With the DiroCHEK®-ELISA, a single A. vasorum-infected dog (6.2%) tested positive. Conclusions Due to potential cross-reactions with A. vasorum in commercially available test kits for the detection of D. immitis antigen, the simultaneous use of highly specific diagnostic methods for the differentiation of these two canine heart worms is recommended. PMID:23148786
Mouiche, M. M. M.; Bayang, H. N.; Assana, E.; Feussom, K. J. M.; Manchang, T. K.; Zoli, P. A.
2018-01-01
A cross-sectional seroprevalence study was conducted on cattle in the North and Adamawa Regions of Cameroon to investigate the status of bovine brucellosis and identify potential risk factors. The diagnosis was carried out using the Rose Bengal Plate test (RBPT) and indirect ELISA (i-ELISA), while questionnaires were used to evaluate risk factors for bovine brucellosis in cattle. The Bayesian approach was used to evaluate the diagnostic tests' sensitivity and specificity. The overall individual level (n = 1031) and herd level (n = 82) seroprevalence were 5.4% (0.4–10.5) and 25.6% (16.2–35.0), respectively. Bayesian analysis revealed sensitivity of 58.3% (26.4–92.7) and 89.6% (80.4–99.4) and specificity of 92.1% (88.7–95.2) and 95.7% (91.1–99.7) for RBPT and i-ELISA, respectively. Management related factors such as region, locality, herd size, and knowledge of brucellosis and animal related factors such as sex and age were significantly associated with seropositivity of brucellosis. Zoonotic brucellosis is a neglected disease in Cameroon. The study highlights the need for control measures and the need to raise public awareness of the zoonotic occurrence and transmission of bovine brucellosis in the country. An integrated disease control strategy mimicking the one health approach involving medical personnel, veterinarians, related stakeholders, and affected communities cannot be overemphasized. PMID:29535853
Quantitation of bovine immunoglobulin isotypes and allotypes using monoclonal antibodies.
Williams, D J; Newson, J; Naessens, J
1990-03-01
A panel of 10 monoclonal antibodies specific for bovine immunoglobulins M, A, G1, G2 and light chains were produced and enzyme-linked immunosorbent assays developed to measure Ig levels in body fluids and culture supernatants using this panel of MAbs. An inhibition ELISA was accurate and sensitive for MAbs of high affinity, detecting levels as low as 10 ng ml-1 of IgM using a high-affinity MAb, IL-A50 (dissociation constant = 1.3 X 10(-11) M). For MAbs of lower affinity (KD of less than 0.25 X 10(-9) M) a sandwich ELISA was more sensitive, detecting 0.1-1.0 microgram ml-1 Ig, provided a conjugate of an anti-light chain MAb was used. Using these ELISA techniques, four pairs of MAbs specific for bovine IgM, IgA, IgG1 and IgG2 respectively, were screened on sera from over 100 cattle of different breeds to determine whether any detected a polymorphic epitope. MAbs IL-A30, IL-A60, IL-A66, IL-A71, IL-A72, IL-A73 and IL-A74 were shown to recognise monomorphic determinants on their respective heavy chains. In contrast, the epitope recognised on the mu-heavy chain by MAb IL-A50, which had previously been shown to be polymorphic, was found to be allelic and inherited under the control of a single gene, probably Cu.
Li, Jin-ming; Zheng, Huai-jing; Wang, Lu-nan; Deng, Wei
2003-04-01
To establish a model for one choosing controls with a suitable concentration for internal quality control (IQC) with qualitative ELISA detection, and a consecutive plotting method on Levey-Jennings control chart when reagent kit lot is changed. First, a series of control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg respectively were assessed for within-run and between-run precision according to NCCLs EP5 document. Then, a linear regression equation (y=bx + a) with best correlation coefficient (r > 0.99) was established based on S/CO values of the series of control serum. Finally, one could choose controls with S/CO value calculated from the equation (y = bx + a) minus the product of the S/CO value multiplying three-fold between-run CV to be still more than 1.0 for IQC use. For consecutive plotting on Levey-Jennings control chart when ELISA kit lot was changed, the new lot kits were used to detect the same series of HBsAg control serum as above. Then, a new linear regression equation (y2 = b2x2 + a2) with best correlation coefficient was obtained. The old one (y1 =b1x1 + a1) could be obtained based on the mean values from above precision assessment. The S/CO value of a control serum detected by new lot kit could be changed to that detected by old kit lot based on the factor of y2/y1. Therefore, the plotting on primary Levey-Jennings control chart could be continued. The within-run coefficient of variation CV of the ELISA method for control serum with 0.2, 0.5, 1.0, 2.0 and 5.0ng/ml HBsAg were 11.08%, 9.49%, 9.83%, 9.18% and 7.25%, respectively, and between-run CV were 13.25%, 14.03%, 15.11%, 13.29% and 9.92%. The linear regression equation with best correlation coefficient from a test at random was y = 3.509x + 0.180. The suitable concentration of control serum for IQC could be 0.5ng/ml or 1.0ng/ml. The linear regression equation from the old lot and other two new lots of the ELISA kits were y1 = 3.550(x1) + 0.226, y2 = 3.238(x2) +0.388, and y3 =3.428(x3) + 0.148, respectively. Then, the transferring factors of 0.960 (y2/y1) and 0.908 (y3/y1) were obtained. The results shows that the model established for IQC control serum concentration selecting and for consecutive plotting on control chart when the reagent lot is changed is effective and practical.
Determination of egg proteins in snack food and noodles.
Williams, Kristina M; Westphal, Carmen D; Shriver-Lake, Lisa C
2004-01-01
Egg is one of the 5 major allergenic foods that are responsible for more than 3/4 of food allergies in children. Food-allergic responses can be controlled by avoidance of the offending foods. The applicability of a commercial enzyme-linked immunosorbent assay (ELISA) kit for the detection of egg in food products such as cookies, crackers, pretzels, salad dressings, and raw and cooked noodles was evaluated. A preliminary evaluation of an antibody-based biosensor was also performed. A National Institute of Standards and Technology (NIST) whole dried egg powder reference material, SRM 8415, was used as a standard. A homogeneous and stable aqueous egg suspension was prepared for the evaluation of the performance of the Veratox for Egg Allergen Test (Neogen Corp., Lansing, MI). This test does not detect egg yolk proteins. Each gram of the aqueous dried egg suspension contained 643 microg whole dried egg, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. When cookies, crackers, salad dressings, noodles, and ice cream were spiked at a level of 24 mg/kg SRM 8415, recoveries for whole egg averaged about 28%. All foods containing egg as indicated on the ingredient label were found positive by the Veratox test. No false positives occurred in samples that did not contain eggs. Similar results were obtained using the Naval Research Laboratory (NRL) array biosensor, an evanescent wave fluoroimmunosensor. Results for cooked noodles showed that they contained <1% of the egg found in uncooked noodles. A comparison of extracts from cooked and uncooked noodles by sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) revealed differences in protein profiles. The boiling of the noodles could have reduced the immunoreactivity of the egg proteins to the antibodies used in the kit or rendered the egg proteins nonextractable.
Stelzer-Braid, Sacha; Wong, Bruce; Robertson, Peter; Lynch, Garry W; Laurie, Karen; Shaw, Robert; Barr, Ian; Selleck, Paul W; Baleriola, Cristina; Escott, Ros; Katsoulotos, Gregory; Rawlinson, William D
2008-10-01
Commercial serological assays to determine influenza A H5N1 infection are available, although the accuracy and reproducibility of these are not reported in detail. This study aimed to assess the validity of a commercial ELISA H5 hemagglutinin (HA) antibody kit. A commercial ELISA for detection of antibodies towards influenza A H5 HA was evaluated using human sera from vaccinated individuals. The ELISA was used to screen 304 sera with elevated influenza A complement fixation titres collected between the period 1995-2007. The ELISA was found to be accurate for sera with high levels of anti-H5 antibodies, and would be useful in clinical settings where a rapid result is required. Thirteen of the stored sera were positive using the ELISA, but were confirmed as negative for H5N1 exposure using further serological tests. Absorption studies suggested that antibodies towards seasonal H3N2 and H1N1 influenza may cross-react with H5 antigen, giving false positive results with the ELISA.
2011-01-01
Background PreImplantation Factor (PIF), a novel peptide secreted by viable embryos is essential for pregnancy: PIF modulates local immunity, promotes decidual pro-adhesion molecules and enhances trophoblast invasion. To determine the role of PIF in post-fertilization embryo development, we measured the peptide's concentration in the culture medium and tested endogenous PIF's potential trophic effects and direct interaction with the embryo. Methods Determine PIF levels in culture medium of multiple mouse and single bovine embryos cultured up to the blastocyst stage using PIF-ELISA. Examine the inhibitory effects of anti-PIF-monoclonal antibody (mAb) added to medium on cultured mouse embryos development. Test FITC-PIF uptake by cultured bovine blastocysts using fluorescent microscopy. Results PIF levels in mouse embryo culture medium significantly increased from the morula to the blastocyst stage (ANOVA, P = 0.01). In contrast, atretic embryos medium was similar to the medium only control. Detectable - though low - PIF levels were secreted already by 2-cell stage mouse embryos. In single bovine IVF-derived embryos, PIF levels in medium at day 3 of culture were higher than non-cleaving embryos (control) (P = 0.01) and at day 7 were higher than day 3 (P = 0.03). In non-cleaving embryos culture medium was similar to medium alone (control). Anti-PIF-mAb added to mouse embryo cultures lowered blastocyst formation rate 3-fold in a dose-dependent manner (2-way contingency table, multiple groups, X2; P = 0.01) as compared with non-specific mouse mAb, and medium alone, control. FITC-PIF was taken-up by cultured bovine blastocysts, but not by scrambled FITC-PIF (control). Conclusions PIF is an early embryo viability marker that has a direct supportive role on embryo development in culture. PIF-ELISA use to assess IVF embryo quality prior to transfer is warranted. Overall, our data supports PIF's endogenous self sustaining role in embryo development and the utility of PIF- ELISA to detect viable embryos in a non-invasive manner. PMID:21569635
Chughtai, Muhammad I; Maqbool, Uzma; Iqbal, Mazhar; Shah, Muhammad S; Fodey, Terence
2017-12-02
This study was undertaken to develop and validate direct competitive ELISA for the determination of chloramphenicol residues in bovine milk. Antisera and an enzyme-tracer for chloramphenicol were prepared and used to develop an ELISA with inhibition concentrations, IC 20 and IC 50 , of 0.09 and 0.44 ng mL -1 , respectively. Milk samples were spiked with standards equivalent to 0, 0.2, 0.3, 0.5, 1.0 & 1.5 ng mL -1 and extracted in methanol. The mean recoveries were found to be 73-100% with coefficient of variance 7-11%. The decision limit (CCα) and detection capability (CCβ) were calculated as 0.10 and 0.12 ng mL -1 , respectively. The results were found comparable with the commercial ELISA, having recoveries of 87 to 100%, CCα 0.09 ng mL -1 and CCβ 0.12 ng mL -1 . As per Commission Decision 2002/657/EC, in-house ELISA was further validated by using LC-MS/MS. Mass spectral acquisition was done by using electrospray ionization in the negative ion mode applying single reaction monitoring of the diagnostic transition reaction for CAP (m/z 152, 194 and 257). The calibration curve showed good linearity in concentrations from 0.025 to 1.6 ng mL -1 with correction coefficient 0.9902. The mean recoveries were found to be 88 to 100%. The CCα was calculated as 0.057 ng mL -1 and CCβ 0.10 ng mL -1 . Since CCα and CCβ are less than half of the MRPL (0.15 ng mL -1 ), the test was found suitable for screening and quantification of CAP residues in bovine milk samples. Results of surveillance studies indicated that out of 31 analyzed milk samples, 12.9% samples were found with CAP residues but only 3.2% samples were declared positive with maximum concentration 0.31 ng mL -1 , slightly above the MRPL.
Guswanto, Azirwan; Allamanda, Puttik; Mariamah, Euis Siti; Munkjargal, Tserendorf; Tuvshintulga, Bumduuren; Takemae, Hitoshi; Sivakumar, Thillaiampalam; AbouLaila, Mahmoud; Terkawi, Mohamad Alaa; Ichikawa-Seki, Madoka; Nishikawa, Yoshifumi; Yokoyama, Naoaki; Igarashi, Ikuo
2017-05-30
Three types of immunochromatographic test (ICT) strips were prepared for the detection of an antibody response against spherical body protein 4 (SBP-4) of Babesia bovis (bovICT), C-terminal-truncated rhoptry-associated protein 1 (rRAP1/CT17) of B. bigemina (bigICT), and the combination of both proteins (dual-ICT). The evaluation of their performance was conducted using a confirmed positive and negative serum panel for B. bovis and B. bigemina. Together with ELISA, the ICT strips were applied to determine the seroprevalence of bovine babesiosis in Western Java, Indonesia. Among 991 serum samples, 28.4%, 25.3%, and 24.5% of cattle were detected to be seropositive to B. bovis infection using ELISA, bovICT, and dual-ICT, respectively. B. bigemina seropositive was detected in 27.1%, 24.2%, and 22.8% of samples using ELISA, bigICT, and dual-ICT, respectively. The comparison of ICT strips and ELISA results using field serum samples showed good agreement with Kappa values >0.7 between all methods The application of ICT strips is preferable in the field situations where rapid diagnosis is required. Furthermore, the data showed the current seroprevalence of bovine babesiosis in Western Java, Indonesia, and efficient control strategies are needed to reduce economic losses due to the disease. Copyright © 2017 Elsevier B.V. All rights reserved.
Zhi, Wenbo; Wang, Meiyao
2014-01-01
The validation of putative biomarker candidates has become the major bottle-neck in protein biomarker development. Conventional immunoaffinity methods are limited by the availability of antibodies and kits. Here we demonstrated the feasibility of using the selected reaction monitoring (SRM) without isotope labeling to achieve fast and reproducible quantification of serum proteins. The SRM/MRM assays for three standard serum proteins, including ceruloplasmin (CP), serum aymloid A (SAA) and sex hormone binding globulin (SHBG) have good linear ranges, generally 103 – 104. There are almost perfect correlations between SRM intensities and the loaded peptide amounts (R2 is usually ~0.99). Our data suggest that SRM/MRM is able to quantify proteins at 0.2 – 2 fmol level, which are comparable to the commercial ELISA/LUMINEX kits for these proteins. Excellent correlations between SRM/MRM and ELISA/LUMINEX assays were observed for SAA and SHBG (R2 = 0.928 and 0.851 respectively). The correlation between SRM/MRM and ELISA for CP is less desirable (R2 = 0.565). The reproducibility for SRM/MRM assays is generally very good but may depend on the proteins/peptides (R2 = 0.931 and 0.882 for SAA and SHBG, and 0.723 for CP). SRM/MRM assay without isotope labeling is a rapid and useful method for protein biomarker validation in a modest number of samples and is especially useful when other assays such as ELISA or Luminex beads are not available. PMID:21594933
Norhaida, A; Suharni, M; Liza Sharmini, A T; Tuda, J; Rahmah, N
2008-03-01
Currently, the laboratory diagnosis of toxocariasis, caused by Toxocara canis or T. cati, mainly relies on serological tests. Unfortunately, however, the specificities of most of the commercial tests that are available for the serodiagnosis of this disease are not very high and this may cause problems, especially in tropical countries where co-infections with other helminths are common. In an effort to develop a serological assay with improved specificity for the detection of Toxocara infection, an IgG(4)-ELISA based on a recombinant version (rTES-30USM) of the 30-kDa Toxocara excretory-secretory antigen (TES-30) has recently been developed. To produce the antigen, the TES-30 gene was cloned via assembly PCR, subcloned into a His-tagged prokaryotic expression vector, and purified by affinity chromatography using Ni(2+)-nitrilotriacetic-acid (Ni-NTA) resin. The performance of the ELISA based on the recombinant antigen was then compared with that of commercial kit, based on an IgG-ELISA, for the serodiagnosis of toxocariasis (Toxocara IgG-ELISA; Cypress Diagnostics, Langdorp, Belgium). Both assays were used to test 338 serum samples, including 26 samples from probable cases of toxocariasis. Assuming that all the probable cases were true cases, the assay based on rTES-30USM demonstrated a sensitivity of 92.3% (24/26) and a specificity of 89.6% (103/115) whereas the commercial kit exhibited a sensitivity of 100% (26/26) but a specificity of only 55.7% (64/115). The high sensitivity and specificity exhibited by the new IgG(4)-ELISA should make the assay a good choice for use in tropical countries and any other area where potentially cross-reactive helminthic infections are common.
Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays
Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D
2002-01-01
Aims: To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). Methods: The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques—an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. Results: All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (κ > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (κ = 0.63). Conclusion: The assay kit marketed as Varelisa allows accurate detection of LKM1. PMID:12461054
Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.
Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D
2002-12-01
To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.
Niskanen, R
1993-10-02
A positive relationship was found between the prevalence of cows in a herd which were antibody-positive for bovine viral diarrhoea virus (BVDV) and the level of antibodies to the virus in bulk tank milk as determined by an indirect enzyme-linked immunosorbent assay (ELISA). In herds with an ELISA absorbance value of up to 0.20 there were very few or no antibody-positive cows, whereas in herds with an ELISA absorbance value of at least 0.81, 87 to 100 per cent of the lactating cows were antibody-positive to BVDV. An analysis of the level of antibodies to BVDV in milk samples from Sweden and Finland showed that of 123 Swedish herds, 83.7 per cent had detectable antibodies to BVDV in their bulk milk whereas only 3.1 per cent of the 291 Finnish samples were antibody-positive. The incidence of BVDV infection in 105 herds in one area of Sweden was determined by analysing two samples of bulk tank milk taken one year apart. The infection had apparently occurred recently in five of these dairy herds.
Surujballi, Om; Mallory, Maria
2001-01-01
A competitive enzyme-linked immunosorbent assay (ELISA) using a specific monoclonal antibody (M898) was developed for detection of bovine antibodies to Leptospira interrogans serovar pomona. This assay was evaluated using field sera (n = 190) with serovar pomona microscopic agglutination test (MAT) titers of ≥100 as the positive population (group A); field sera (n = 1,445) which were negative in the MAT (1:100 dilution) for serovar pomona (group B); and sera (from a specific-pathogen-free cattle herd [n = 210]) which were negative in the MAT (1:100 dilution) for serovars canicola, copenhageni, grippotyphosa, hardjo, pomona, and sejroe (group C). At the cutoff point recommended by receiver operating characteristic (ROC) curve analysis of the combined ELISA results of serum groups A, B, and C, the sensitivity and specificity values were 93.7 and 96.3%, respectively. The value for the area under this ROC curve was 0.977, indicating a high level of accuracy for the ELISA. Similar results were obtained from the analysis of the combined results of serum groups A and B and from the analysis of the combined results of serum groups A and C. PMID:11139193
[Microbiology--laboratory examinations for bacterias].
Hen, Renjun; Imafuku, Yuji; Yoshida, Hiroshi
2002-11-01
As it has been required to identify pathogenic microbes in shorter times, simple and rapid methods have been developed and used. Here, we summarized the present situation of rapid diagnostic testing in clinical microbiology in Japan, and also presented our results on PBP2' detection. The rapid test kits available in Japan for E. coli, Helicobacter pylori, Salmonella, Streptococcus and Staphylococcus aureus were described. Rapid examination methods are based mainly on immunologic reactions, which included slide agglutination using latex particle, immunochromatography and ELISA. Times required for the identification are 10 to 15 minutes. Moreover, rapid test kits employing PCR are also marketed. Further, we evaluated MRSA-LA "Seiken" which is a rapid detection kit for PBP2' produced by MRSA. The test was shown to be highly sensitive and specific. For the rapid identification of pathogenic microbes, simple and rapid test kits described here will be used more in clinical diagnosis.
Amengual, O; Forastiero, R; Sugiura-Ogasawara, M; Otomo, K; Oku, K; Favas, C; Delgado Alves, J; Žigon, P; Ambrožič, A; Tomšič, M; Ruiz-Arruza, I; Ruiz-Irastorza, G; Bertolaccini, M L; Norman, G L; Shums, Z; Arai, J; Murashima, A; Tebo, A E; Gerosa, M; Meroni, P L; Rodriguez-Pintó, I; Cervera, R; Swadzba, J; Musial, J; Atsumi, T
2017-03-01
Objective A task force of scientists at the International Congress on Antiphospholipid Antibodies recognized that phosphatidylserine-dependent antiprothrombin antibodies (aPS/PT) might contribute to a better identification of antiphospholipid syndrome (APS). Accordingly, initial and replication retrospective, cross-sectional multicentre studies were conducted to ascertain the value of aPS/PT for APS diagnosis. Methods In the initial study (eight centres, seven countries), clinical/laboratory data were retrospectively collected. Serum/plasma samples were tested for IgG aPS/PT at Inova Diagnostics (Inova) using two ELISA kits. A replication study (five centres, five countries) was carried out afterwards. Results In the initial study ( n = 247), a moderate agreement between the IgG aPS/PT Inova and MBL ELISA kits was observed ( k = 0.598). IgG aPS/PT were more prevalent in APS patients (51%) than in those without (9%), OR 10.8, 95% CI (4.0-29.3), p < 0.0001. Sensitivity, specificity, positive (LR+) and negative (LR-) likelihood ratio of IgG aPS/PT for APS diagnosis were 51%, 91%, 5.9 and 0.5, respectively. In the replication study ( n = 214), a moderate/substantial agreement between the IgG aPS/PT results obtained with both ELISA kits was observed ( k = 0.630). IgG aPS/PT were more prevalent in APS patients (47%) than in those without (12%), OR 6.4, 95% CI (2.6-16), p < 0.0001. Sensitivity, specificity, LR + and LR- for APS diagnosis were 47%, 88%, 3.9 and 0.6, respectively. Conclusions IgG aPS/PT detection is an easily performed laboratory parameter that might contribute to a better and more complete identification of patients with APS.
Furtado, Agustin; Torres, Fabrício Dias; Franco, Ana Cláudia; Maisonnave, Jacqueline; Roehe, Paulo Michel
2016-01-01
Bovine herpesviruses (BoHVs) types 1 (BoHV-1) and 5 (BoHV-5) are alphaherpesviruses of major importance to the bovine production chain. Such viruses are capable of establishing latent infections in neuronal tissues. Infected animals tend to develop a serological response to infection; however, such response—usually investigated by antibody assays in serum—may eventually not be detected in laboratory assays. Nevertheless, serological tests such as virus neutralization (VN) and various enzyme-linked immunosorbent assays (ELISAs) are widely employed to check individual or herd status of BoHV infections. The correlation between detection of antibodies and the presence of viral nucleic acids as indicatives of infection in infected cattle has not been deeply examined. In order to investigate such correlation, 248 bovine serum samples were tested by VN to BoHV-1 and BoHV-5, as well as in a widely employed (though not type-differential) gB ELISA (IDEXX IBR gB X2 Ab Test) in search for antibodies to BoHVs. Immediately after blood withdrawal, cattle were slaughtered and trigeminal ganglia (TG) excised for DNA extraction and viral nucleic acid detection (NAD) by nested PCR. Neutralizing antibodies to BoHV-1 and/or BoHV-5 were detected in 44.8% (111/248) of sera, whereas the gB ELISA detected antibodies in 51.2% (127/248) of the samples. However, genomes of either BoHV-1, BoHV-5, or both, were detected in TGs of 85.9% (213/248) of the animals. These findings reveal that the assays designed to detect antibodies to BoHV-1 and/or BoHV-5 employed here may fail to detect a significant number of latently infected animals (in this study, 35.7%). From such data, it is clear that antibody assays are poorly correlated with detection of viral genomes in BoHV-1 and BoHV-5-infected animals. PMID:27224314
Brar, A P S; Sood, N K; Kaur, P; Singla, L D; Sandhu, B S; Gupta, K; Narang, D; Singh, C K; Chandra, M
2017-10-01
Bovine calf scours reported to be caused by multiple aetiologies resulting in heavy mortality in unweaned calves and huge economic loss to the dairy farmers. Among these, cryptosporidiosis is an emerging waterborne zoonoses and one of the important causes of neonatal calf diarrhoea. Poor immune response coupled with primary cryptosporidial infections predispose neonatal calves to multiple secondary infections resulting in their deaths. In the present study, faecal samples from 100 diarrhoeic calves randomly picked up out of 17 outbreaks of bovine calf diarrhoea in periurban Ludhiana, Punjab in Northern India were subjected to conventional (microscopy, modified Zeihl-Neelsen (mZN) staining) and immunological and molecular techniques (faecal antigen capture ELISA and PCR) for detection of primary Cryptosporidium parvum infection as well as other frequently reported concurrent pathogens, viz. rotavirus and coronavirus, Salmonella spp., Escherichia coli, Clostridium perfringens and Eimeria spp. The faecal antigen capture ELISA and PCR revealed 35% prevalence of C. parvum in contrast to 25% by mZN staining with a relatively higher prevalence (66·7%) in younger (8-14-day-old) calves. The detection rate of the other enteropathogens associated with C. parvum was 45·71% for C. perfringens followed by Salmonella spp (40·0%), rotavirus (36·0%), coronavirus (16·0%), E. coli (12·0%) and Eimeria spp (4·0%) The sensitivity for detection of C. parvum by ELISA and mZN staining in comparison to PCR was 97·14% and 72·72%, respectively. An important finding of the study was that C. parvum alone was found in only 10% of the diarrhoeic faecal samples, whereas, majority of the samples (90%) showed mixed infections ranging from a combination of two to five agents. This is the first documentary proof of C. parvum and associated pathogens responsible for severe periurban outbreaks of bovine calf diarrhoea culminating in heavy mortality from Northern India.
Caruso, C; Prato, R; Ingravalle, F; Vecchio, D; Sciarra, A; Ternavasio, M; Ceccarelli, L; Martucciello, A; Galiero, G; De Carlo, E; Masoero, L
2016-12-01
Both Bovine herpesvirus (BoHV-1) and Bubaline herpesvirus (BuHV-1) have been reported to cross the species barrier. Antibody seroconversion in glycoprotein E (gE) blocking ELISA during BuHV-1 infection has been documented. Recent diagnostic efforts have focused on the development and application of discriminatory tests to distinguish between infections with BoHV-1 and BuHV-1. To evaluate the impact and distribution of these two infections in water buffalo farms in two regions (Piedmont (n = 3) and Campania (n = 10), Italy) where infectious bovine rhinotracheitis control programs have been implemented. Sampling was carried out on 13 buffalo farms comprising 1089 animals using specific gE-indirect ELISA's test able to discriminate among BoHV-1 and BuHV-1 infections. 59.0% of animals reacted positive to ELISA (irrespective of whether BoHV-1 or BuHV-1 antigen was used) and 86.4% of these were reactive to BuHV-1 only, whereas 11.8% showed absorbance values for both antigens and were classified as inconclusive. There was a statistically significant age-related difference in BuHV-1 infection rates but not in overall individual (47% vs. 58%) or herd prevalence (100% vs. 90%) of infection between the two regions. The low percentage of sera reactive to BoHV-1 (1.8%, 12/643) indicates that BuHV-1 may be the main circulating alphaherpesvirus infection in Mediterranean water buffalo in the two study areas. Since Bubalus bubalis is included in Directive 64/432/EEC on animal health problems affecting intra-community trade in bovine animals, diagnostic testing with nonspecific ELISA for BoHV-1 infection in buffalo may yield false-positive reactions. This scenario could lead to economic losses and hamper buffalo trade and movement, particularly for reproduction purposes.
Franklin, S.P.; Troyer, J.L.; TerWee, J.A.; Lyren, L.M.; Kays, R.W.; Riley, S.P.D.; Boyce, W.M.; Crooks, K.R.; VandeWoude, S.
2007-01-01
Although lentiviruses similar to feline immunodeficiency virus (FIV) are known to infect numerous felid species, the relative utility of assays used for detecting lentiviral infection has not been compared for many of these hosts. We tested bobcats (Lynx rufus), pumas (Felis concolor), and ocelots (Leopardus pardalis) for exposure to lentivirus using five different assays: puma lentivirus (PLV), African lion lentivirus (LLV), and domestic cat FIV-based immunoblots, a commercially available enzyme-linked immunosorbent assay (ELISA) kit, and nested polymerase chain reaction (PCR). Puma lentivirus immunoblots identified more seropositive individuals than the other antibody-detection assays. The commercial ELISA provided a fair ability to recognize seropositive samples when compared with PLV immunoblot for screening bobcats and ocelots, but not pumas. Polymerase chain reaction identified fewer positive samples than PLV immunoblot for all three species. Immunoblot results were equivalent whether the sample tested was serum, plasma, or whole blood. The results from this study and previous investigations suggest that the PLV immunoblot has the greatest ability to detect reactive samples when screening wild felids of North America and is unlikely to produce false positive results. However, the commercial ELISA kit may provide ap adequate alternative for screening of some species and is more easily adapted to field conditions. ?? Wildlife Disease Association 2007.
Watanabe, Eiki; Miyake, Shiro
2018-06-05
Easy-to-use commercial kit-based enzyme-linked immunosorbent assays (ELISAs) have been used to detect neonicotinoid dinotefuran, clothianidin and imidacloprid in Chinese chives, which are considered a troublesome matrix for chromatographic techniques. Based on their high water solubility, water was used as an extractant. Matrix interference could be avoided substantially just diluting sample extracts. Average recoveries of insecticides from spiked samples were 85-113%, with relative standard deviation of <15%. The concentrations of insecticides detected from the spiked samples with the proposed ELISA methods correlated well with those by the reference high-performance liquid chromatography (HPLC) method. The residues analyzed by the ELISA methods were consistently 1.24 times that found by the HPLC method, attributable to loss of analyte during sample clean-up for HPLC analyses. It was revealed that the ELISA methods can be applied easily to pesticide residue analysis in troublesome matrix such as Chinese chives.
Gómez-Ojeda, Armando; Jaramillo-Ortíz, Sarahi; Wrobel, Katarzyna; Wrobel, Kazimierz; Barbosa-Sabanero, Gloria; Luevano-Contreras, Claudia; de la Maza, Maria Pia; Uribarri, Jaime; Del Castillo, Ma Dolores; Garay-Sevilla, Ma Eugenia
2018-03-15
N ε -carboxymethyl-lysine (CML) is measured in food, but there is a controversy concerning the most convenient yet reliable method(s) for this task. This work compares three different ELISA assays and HPLC-ESI-ITMS/MS for the analysis of CML in several food items. The four methods showed the same decreasing order of CML concentration: beef, bacon>chicken > fish>dairy products>grain products>fruits/vegetables. HPLC-ESI-ITMS/MS results highly correlated with those obtained by ELISA performed with monoclonal CML-antibody (β=0.98, p<0.0001) whereas My Bio Source® kit results were not correlated with those provided by Lamider®. Small differences of CML concentrations in food items prepared by different culinary treatment were clearly distinguished by HPLC-ESI-ITMS/MS, but could not always be detected by ELISA. This work demonstrates a reasonable relationship between CM determined by ELISA and HPLC-ESI-ITMS/MS and therefore supports the implementation of ELISA in food CML/AGEs screening. Copyright © 2017. Published by Elsevier Ltd.
Monaci, Linda; Brohée, Marcel; Tregoat, Virginie; van Hengel, Arjon
2011-07-15
Milk allergens are common allergens occurring in foods, therefore raising concern in allergic consumers. Enzyme-linked immunosorbent assay (ELISA) is, to date, the method of choice for the detection of food allergens by the food industry although, the performance of ELISA might be compromised when severe food processing techniques are applied to allergen-containing foods. In this paper we investigated the influence of baking time on the detection of milk allergens by using commercial ELISA kits. Baked cookies were chosen as a model food system and experiments were set up to study the impact of spiking a matrix food either before, or after the baking process. Results revealed clear analytical differences between both spiking methods, which stress the importance of choosing appropriate spiking methodologies for method validation purposes. Finally, since the narrow dynamic range of quantification of ELISA implies that dilution of samples is required, the impact of sample dilution on the quantitative results was investigated. All parameters investigated were shown to impact milk allergen detection by means of ELISA. Copyright © 2011 Elsevier Ltd. All rights reserved.
True HIV seroprevalence in Indian blood donors.
Choudhury, N; Ayagiri, A; Ray, V L
2000-03-01
The National AIDS Control Organization (NACO), the apex body for controlling AIDS in India, projected that HIV seroprevalence would increase from 7/1000 in 1995 to 21.2/1000 in 1997. A high incidence (8.2%) of HIV was observed in blood donors. This study was carried out to find out the true HIV positivity in Indian blood donors. Blood donors from our centre were followed for more than 5 years to determine the true HIV seroprevalence and our result was compared with similar studies from India. Voluntary and relative blood donors who visited the SGPGIMS, Lucknow, since 1993 to June 1998 were included. They were screened for HIV 1/2 by ELISA kits (WHO approved). First-time HIV-positive samples were preserved frozen for further study (stage-I). They were repeated in duplicate and retested with other kits. If found positive, the sample was labelled as ELISA positive (stage-II). ELISA-positive samples were confirmed by Western Blot (WB) at stage-III. A total of 65 288 donors were included and 834 (12.8/1000) were reactive at stage-I. But 1.1/1000 donors were found to be ELISA positive at stage-II, and 0.28/1000 donors were positive by WB at stage-III. The 'seropositivity' rate from the NACO was significantly (P < 0.001) higher than our study. There were five similar Indian studies and seropositivity rate varied from 0.72/1000 (using ELISA and WB) to 5.5/1000 (using ELISA alone). The 'seropositivity' rate from the NACO was significantly (P < 0.001) higher than all these studies. HIV seroprevalence in the present study is lower (P < 0.001) than other Indian figures. The present and other studies confirmed that the projected HIV seroprevalence (82/1000) in Indian blood donors was high. The NACO result was based on one-time ELISA screening reports from zonal blood testing centres which also receive samples from paid donors donating in commercial blood banks. The HIV prevalence of blood donors (and national prevalence) is to be reassessed.
Lumor, Stephen E; Fredrickson, Neal R; Ronningen, Ian; Deen, Bronwyn D; Smith, Kenneth; Diez-Gonzalez, Francisco; Labuza, Theodore P
2012-06-01
This study was conducted to compare the identification of Shiga toxin 1 (Stx1) based on its specific biological activity and based on results of a commercial enzyme-linked immunosorbent assay (ELISA) kit. Stx1 was thermally treated for various periods in phosphate-buffered saline, milk, and orange juice. The residual Stx1 concentration was determined with the commercial ELISA kit, and its residual enzymatic activity (amount of adenine released from a 2,551-bp DNA substrate) was determined with a biological activity assay (BAA). Regression analysis indicated that the inactivation of Stx1 as a function of time followed first-order kinetics. The half-lives determined at 60, 65, 70, 75, 80, and 85°C were 9.96, 3.19, 2.67, 0.72, 0.47, and 0.29 min, respectively, using the BAA. The half-lives determined by the ELISA with thermal treatments at 70, 75, 80, and 85°C were 40.47, 11.03, 3.64, and 1.40 min, respectively. The Z, Q(10), and Arrhenius activation energy values derived by both assays were dissimilar, indicating that the rate of inactivation of the active site of Stx1 was less sensitive to temperature change than was denaturation of the epitope(s) used in the ELISA. These values were 10.28°C and 9.40 and 54.70 kcal/mol, respectively, with the ELISA and 16°C and 4.11 and 34 kcal/mol, respectively, with the BAA. Orange juice enhanced Stx1 inactivation as a function of increasing temperature, whereas inactivation in 2% milk was not very much different from that in phosphate-buffered saline. Our investigation indicates that the ELISA would be a reliable method for detecting the residual toxicity of heat-treated Stx1 because the half-lives determined with the ELISA were greater than those determined with the BAA (faster degradation) at all temperatures and were highly correlated (R(2) = 0.994) with those determined with the BAA.
NASA Astrophysics Data System (ADS)
Shu, Jian; Qiu, Zhenli; Wei, Qiaohua; Zhuang, Junyang; Tang, Dianping
2015-10-01
5,10,15,20-Tetraphenyl-21H,23H-porphine cobalt flat stacking on the reduced graphene oxide with platinum nanoparticles (PtNPs/CoTPP/rGO) were first synthesized and functionalized with monoclonal rabbit anti-aflatoxin B1 antibody (anti-AFB1) for highly efficient electrochemical immunoassay of aflatoxin B1 (AFB1) in this work. Transmission electron microscopy (TEM), atomic force microscope (AFM) and spectral techniques were employed to characterize the PtNPs/CoTPP/rGO hybrids. Using anti-AFB1-conjugated PtNPs/CoTPP/rGO as the signal-transduction tag, a novel non-enzymatic electrochemical immunosensing system was designed for detection of target AFB1 on the AFB1-bovine serum albumin-functionalized sensing interface. Experimental results revealed that the designed immunoassay could exhibit good electrochemical responses for target analyte and allowed the detection of AFB1 at a concentration as low as 5.0 pg mL-1 (5.0 ppt). Intra- and inter-assay coefficients of variation were below 10%. Importantly, the methodology was further validated for analyzing naturally contaminated or spiked blank peanut samples with consistent results obtained by AFB1 ELISA kit, thus providing a promising approach for quantitative monitoring of organic pollutants.
Nguyen, Duc Doan; Busetti, Francesco; Johnson, Stuart Keith; Solah, Vicky Ann
2018-03-01
This study investigated beta-casomorphin 7 (BCM7) in yogurt by means of LC-tandem MS (MS/MS) and enzyme-linked immunosorbent assay (ELISA) and use LC-MS/MS as the "gold standard" method to evaluate the applicability of a commercial ELISA. The level of BCM7 in milk obtained from ELISA analysis was much lower than that obtained by LC-MS/MS analysis and trended to increase during fermentation and storage of yogurt. Meanwhile, the results obtained from LC-MS/MS showed that BCM7 degraded during stages of yogurt processing, and its degradation may have been caused by X-prolyl dipeptidyl aminopeptidase activity. As a result, the commercial sandwich ELISA kit was not suitable for the quantification of BCM7 in fermented dairy milk.
Nakayasu, Miki; Hirano, Minato; Muto, Memi; Kobayashi, Shintaro; Kariwa, Hiroaki; Yoshii, Kentaro
2018-06-23
Tick-borne encephalitis virus (TBEV) is a zoonotic agent causing severe encephalitis in humans. IgM antibody detection is useful for the serological diagnosis of TBEV infection, because IgM has high specificity for each flavivirus and indicates a recent infection. Commercial IgM-ELISA kits are somewhat expensive and difficulties in their sensitivity have been suggested due to their format and formalin-inactivated antigens. Therefore, the development of an inexpensive IgM-ELISA with high specificity and sensitivity is needed. In this study, a μ-capture ELISA was developed to detect TBEV-specific IgM antibodies using subviral particles (SPs) with strep-tag (strep-SP-IgM-ELISA). The results of our strep-SP-IgM-ELISA were highly correlated with diagnoses made by the neutralization test (sensitivity: 94.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in patients who could not be diagnosed with the neutralization test. Besides, 51 of 52 positive samples by a commercial IgM-ELISA were also diagnosed as positive by our strep-SP-IgM-ELISA (98.1%), and our strep-SP-IgM-ELISA could detect anti-TBEV IgM antibodies in all samples that were inconclusive based on the commercial IgM-ELISA. Our strep-SP-IgM-ELISA will be useful for diagnoses in TBE-endemic areas. Copyright © 2018 Elsevier GmbH. All rights reserved.
Evaluation of Cariogenic Bacteria
Nishikawara, Fusao; Nomura, Yoshiaki; Imai, Susumu; Senda, Akira; Hanada, Nobuhiro
2007-01-01
Objectives The evaluation of Mutans streptococci (MS) is one of the index for caries risk. DentocultTM and CRTTM are commercial kits to detect and evaluate MS, conveniently. However, the evaluation of MS has also been carried out simply using an instruction manual. But the instruction manual is not easy to use for evaluation of MS. The aim of this study was to examine the utility of modified Mitis-Salivalius Bacitracin (MSB) agar medium compared with MSB agar medium and commercial kits, and to establish a convenient kit (mMSB-kit) using modified MSB agar. Methods The MS in stimulated saliva from 27 subjects were detected by MSB, modified MSB agar medium and commercial kits. Laboratory and clinically isolated strains of MS were similarly evaluated. The ratios of MS in detected bacteria were compared by ELISA. Results The scores using an mMSB-kit on the basis of modified MSB agar medium were tabulated. Saliva samples showed different levels of MS between culture methods and the commercial kit. Some samples which were full of MS were not detected by the commercial kit. The detection of MS by modified MSB agar medium and mMSB-kit were significantly higher when compared with MSB agar medium,CRTTM, (P< .01) and Dentocult SMTM (P<.05). Conclusion The sensitivity for detection of MS is higher for modified MSB agar medium when compared with MSB agar medium. The mMSB-kit can be used simply, and can be an important contributor for the evaluation of MS as a caries risk factor. PMID:19212495
Infantes-Lorenzo, José Antonio; Moreno, Inmaculada; Risalde, María de Los Ángeles; Roy, Álvaro; Villar, Margarita; Romero, Beatriz; Ibarrola, Nieves; de la Fuente, José; Puentes, Eugenia; de Juan, Lucía; Gortázar, Christian; Bezos, Javier; Domínguez, Lucas; Domínguez, Mercedes
2017-01-01
Bovine purified protein derivative (bPPD) and avian purified protein derivative (aPPD) are widely used for bovine tuberculosis diagnosis. However, little is known about their qualitative and quantitative characteristics, which makes their standardisation difficult. In addition, bPPD can give false-positive tuberculosis results because of sequence homology between Mycobacterium bovis ( M. bovis ) and M. avium proteins. Thus, the objective of this study was to carry out a proteomic characterisation of bPPD, aPPD and an immunopurified subcomplex from bPPD called P22 in order to identify proteins contributing to cross-reactivity among these three products in tuberculosis diagnosis. Trypsin digests of bPPD, aPPD and P22 were analysed by nanoscale liquid chromatography-electrospray ionization tandem mass spectrometry. Mice were immunised with bPPD or aPPD, and their serum was tested by indirect ELISA for reactivity against these preparations as well as against P22. A total of 456 proteins were identified in bPPD, 1019 in aPPD and 118 in P22; 146 of these proteins were shared by bPPD and aPPD, and 43 were present in all three preparations. Candidate proteins that may cause cross-reactivity between bPPD and aPPD were identified based on protein abundance and antigenic propensity. Serum reactivity experiments indicated that P22 may provide greater specificity than bPPD with similar sensitivity for ELISA-type detection of antibodies against M. tuberculosis complex. The subpreparation from bPPD called P22 may be an alternative to bPPD for serodiagnosis of bovine tuberculosis, since it shares fewer proteins with aPPD than bPPD does, reducing risk of cross-reactivity with anti- M. avium antibodies.
Tanner, M; Inlameia, O; Michel, A; Maxlhuza, G; Pondja, A; Fafetine, J; Macucule, B; Zacarias, M; Manguele, J; Moiane, I C; Marranangumbe, A S; Mulandane, F; Schönfeld, C; Moser, I; van Helden, P; Machado, A
2015-12-01
Bovine tuberculosis (BTB) and brucellosis are prevalent in buffaloes of the Kruger National Park (KNP, South Africa). Both diseases were considered to have no or a very low prevalence in wildlife and livestock in and around the Limpopo National Park (LNP, Mozambique). The same applies for tuberculosis in Gonarezhou National Park (GNP, Zimbabwe), but just recently, BTB was detected in buffaloes in the GNP and fears arose that the disease might also spread to the LNP as a result of the partial removal of the fences between the three parks to form the Great Limpopo Transfrontier Park. To assess the status of both diseases in and around LNP, 62 buffaloes were tested for bovine tuberculosis (BTB) and bovine brucellosis. The percentage of positive BTB reactors in buffalo was 8.06% using BovidTB Stat-Pak® and 0% with BOVIGAM® IFN-γ test and IDEXX ELISA. The brucellosis seroprevalence in buffalo was found to be 17.72% and 27.42% using Rose Bengal Test (RBT) and ELISA, respectively. In addition, 2445 cattle in and around the LNP were examined for BTB using the single intradermal cervical comparative tuberculin test (SICCT), and an apparent prevalence of 0.98% was found with no significant difference inside (0.5%) and outside (1.3%) the park. This is the first published report on the presence of positive reactors to BTB and bovine brucellosis in buffalo and cattle in and outside the LNP. Monitoring the wildlife-livestock-human interface of zoonotic high-impact diseases such as BTB and brucellosis is of outmost importance for the successful implementation and management of any transfrontier park that aims to improve the livelihoods of the local communities. © 2014 Blackwell Verlag GmbH.
Jiang, Jinqing; Zhang, Haitang; Li, Guangling; Yang, Xuefeng; Li, Renfeng; Wang, Ziliang; Wang, Jianhua
2012-04-01
This paper presents the generation of monoclonal antibodies (mAbs) with high specificity against 19-nortestosterone (NT) through cell fusion procedures, and the development of mAb-based heterologous direct competitive enzyme-linked immunoabsorbent assay (dcELISA) methods to detect NT residue using one of these hybridomas (clone 3B8-E6). Under optimal experimental conditions, this assay exhibited a working range of 0.004 to 19 ng/mL with IC₅₀ and limit of detection values of 0.28 and 0.002 ng/mL, respectively, when it was run in 0.01M phosphate-buffered saline (pH 7.4). Except for minor cross-reactivity with β-boldenone (6.9%) and trenbolone (1.2%), other interference to the assay was negligible (<0.05%). No significant differences (P > 0.05) were found for IC₅₀ values when the pH of the assay buffer ranged from 6 to 8 and phosphate ion concentration was less than 20 mM. The dcELISA can tolerate higher concentrations of methanol than other organic solvents tested. When applied to bovine sample, the correlation coefficients (R) of the dcELISA and GC-MS data were 0.9918 in muscle, 0.9834 in liver, and 0.9976 in kidney. Therefore, this assay has the potential to be incorporated into a quantitative monitoring program for the rapid screening of NT residue in food. © 2012 Institute of Food Technologists®
Ayoola, Modupe Comfort; Akinseye, Victor Oluwatoyin; Cadmus, Eniola; Awosanya, Emmanuel; Popoola, Olufemi Akinyele; Akinyemi, Oluwaseun Oladapo; Perrett, Lorraine; Taylor, Andrew; Stack, Judy; Moriyon, Ignacio; Cadmus, Simeon Idowu
2017-01-01
Introduction Brucellosis is a neglected zoonosis of public health importance. This study was conducted to determine the prevalence and risk factors of brucellosis among slaughtered cattle as well as challenges to the protection of abattoir workers in Nigeria. Methods A slaughterhouse study was conducted in a major abattoir in Ibadan from March to August, 2013. To diagnose brucellosis, serum samples from 1,241 slaughtered cattle were tested using Rose-Bengal test (RBT) and competitive enzyme-linked immunosorbent assay (cELISA); again, 57 milk samples were tested with milk ring test (MRT) and indirect ELISA (iELISA). Furthermore, a survey on the usage of personal protective equipment (PPE) and challenges to its use by abattoir workers was done. Data were analysed using Stata 12. Results Seroprevalence by RBT was 7.8%; 77.3% (75/97) of these were corroborated by cELISA. Prevalence in milk samples by MRT and indirect ELISA were 33.3% and 3.5%, respectively. Sex (OR: 2.5; 95%CI:1.3-4.5) was the factor significantly associated with Brucella seropositivity. None of the abattoir workers used standard protective overalls; while, 99.6% of the meat handlers and 84.1% of the butchers worked barefoot. Most of the workers (75.7%) wore no protective gloves. The respondents agreed that provision of free PPE and sanctions against non-users would encourage its use. Conclusion Our findings indicate moderate prevalence (7.8%) of bovine brucellosis with sex of cattle being a risk factor. A notable barrier to better protection of abattoir workers against brucellosis is perceived inconvenience arising from use of gloves. Therefore, preventive and control measures against brucellosis must include education and use of PPE among abattoir workers. PMID:29255538
Ayoola, Modupe Comfort; Akinseye, Victor Oluwatoyin; Cadmus, Eniola; Awosanya, Emmanuel; Popoola, Olufemi Akinyele; Akinyemi, Oluwaseun Oladapo; Perrett, Lorraine; Taylor, Andrew; Stack, Judy; Moriyon, Ignacio; Cadmus, Simeon Idowu
2017-01-01
Brucellosis is a neglected zoonosis of public health importance. This study was conducted to determine the prevalence and risk factors of brucellosis among slaughtered cattle as well as challenges to the protection of abattoir workers in Nigeria. A slaughterhouse study was conducted in a major abattoir in Ibadan from March to August, 2013. To diagnose brucellosis, serum samples from 1,241 slaughtered cattle were tested using Rose-Bengal test (RBT) and competitive enzyme-linked immunosorbent assay (cELISA); again, 57 milk samples were tested with milk ring test (MRT) and indirect ELISA (iELISA). Furthermore, a survey on the usage of personal protective equipment (PPE) and challenges to its use by abattoir workers was done. Data were analysed using Stata 12. Seroprevalence by RBT was 7.8%; 77.3% (75/97) of these were corroborated by cELISA. Prevalence in milk samples by MRT and indirect ELISA were 33.3% and 3.5%, respectively. Sex (OR: 2.5; 95%CI:1.3-4.5) was the factor significantly associated with Brucella seropositivity. None of the abattoir workers used standard protective overalls; while, 99.6% of the meat handlers and 84.1% of the butchers worked barefoot. Most of the workers (75.7%) wore no protective gloves. The respondents agreed that provision of free PPE and sanctions against non-users would encourage its use. Our findings indicate moderate prevalence (7.8%) of bovine brucellosis with sex of cattle being a risk factor. A notable barrier to better protection of abattoir workers against brucellosis is perceived inconvenience arising from use of gloves. Therefore, preventive and control measures against brucellosis must include education and use of PPE among abattoir workers.
Wasniewski, M; Labbe, A; Tribout, L; Rieder, J; Labadie, A; Schereffer, J L; Cliquet, F
2014-01-01
For several years, international movements with pets have greatly increased. Most countries have relaxed their quarantine measures and adopted a scheme combining vaccination of pets against rabies followed by a serological test to check the efficacy of vaccination. This new scheme has been strongly supported by the OIE, WHO and the European Commission to facilitate the free movement of people and pets around the world. Currently, only two reference methods are recognised and prescribed (the FAVN test and the RFFIT) to measure rabies antibody levels in serum samples for international trade. They are reliable and valuable methods of assessing the efficacy of rabies vaccination but they are time-consuming and require well-trained people and specialised laboratory facilities. A few years ago, an ELISA (Platelia™ Rabies II kit ad usum Veterinarium) was developed for domestic carnivores and wildlife. To our knowledge, this ELISA is the only one certified and prescribed by the OIE. Following its marketing, one task of the EURL for rabies serology was to evaluate the performance of laboratories using this new kit. The results revealed that 26% of the participants, which were already approved laboratories for rabies serology, failed the inter-laboratory trial. Such unsatisfactory results have never been observed during any of the previous proficiency tests organised annually since 2000 by the EURL for rabies serology using reference methods. More investigations were undertaken through internal and collaborative studies to assess the performance of this newly marketed ELISA kit. The results of the internal study revealed that even with a specificity of 100%, the sensitivity evaluated on 593 samples of domestic carnivores came to 78.2%. An issue regarding the underestimation of serum titres was also revealed during the study. The results of a collaborative study involving 23 international laboratories reinforced the preliminary conclusions regarding lack of sensitivity. Indeed, only 5 laboratories out of the 23 obtained satisfactory results. We therefore suggest adopting a threshold of 0.3 EU/mL instead of 0.5 EU/mL to increase the sensitivity of the test. Copyright © 2013 Elsevier B.V. All rights reserved.
Immunodiagnostic Value of Echinococcus Granulosus Recombinant B8/1 Subunit of Antigen B.
Savardashtaki, Amir; Sarkari, Bahador; Arianfar, Farzane; Mostafavi-Pour, Zohreh
2017-06-01
Cystic echinococcosis (CE), as a chronic parasitic disease, is a major health problem in many countries. The performance of the currently available serodiagnostic tests for the diagnosis of CE is unsatisfactory. The current study aimed at sub-cloning a gene, encoding the B8/1 subunit of antigen B (AgB) from Echinococcus granulosus, using gene optimization for the immunodiagnosis of human CE. The coding sequence for AgB8/1 subunit of Echinococcus granulosus was selected from GenBank and was gene-optimized. The sequence was synthesized and inserted into pGEX-4T-1 vector. Purification was performed with GST tag affinity column. Diagnostic performance of the produced recombinant antigen, native antigen B and a commercial ELISA kit were further evaluated in an ELISA system, using a panel of sera from CE patients and controls. SDS-PAGE demonstrated that the protein of interest had a high expression level and purity after GST tag affinity purification. Western blotting verified the immunoreactivity of the produced recombinant antigen with the sera of CE patients. In an ELISA system, the sensitivity and specificity (for human CE diagnosis) of the recombinant antigen, native antigen B and commercial kit were respectively 93% and 92%, 87% and 90% and 97% and 95%. The produced recombinant antigen showed a high diagnostic value which can be recommended for serodiagnosis of CE in Iran and other CE-endemic areas. Utilizing the combination of other subunits of AgB8 would improve the performance value of the introduced ELISA system.
2012-01-01
Background Contagious agalactia (CA) of sheep and goats caused by Mycoplasma agalactiae is a widely occurring economically important disease that is difficult to control. The ELISA is commonly used for the serological detection of CA but it has some limitations and the performance of the available tests have not been properly evaluated. Two commercial ELISA kits are widely used, one involving a fusion protein as target antigen and the other a total antigen. The objectives were to compare these tests by evaluating: i. Their diagnostic sensitivity and specificity, the relevance of the recommended cut-off points, the correlation between the two tests, and, the correlation between serology data and the milk shedding of M. agalatiae; ii. The influence of extrinsic factors such as the targeted animal species, geographical origin of the samples, intra-specific variability of M. agalactiae and concurrent mycoplasma infections. A sample of 5900 animals from 211 farms with continuous CA monitoring for 20 years and no prior vaccination history was used. The infection status was known from prior bacteriological, epidemiological and serological monitoring with a complementary immunoblotting test. Results The average diagnostic sensitivity was 56% [51.8–59.8] for the fusion protein ELISA and 84% [81.3–87.2] for the total antigen ELISA, with noteworthy flock-related variations. The average diagnostic specificity for the fusion protein ELISA was 100% [99.9–100], and for the total antigen ELISA differed significantly between goats and sheep: 99.3% [97.4–99.9] and 95.7% [93.8–97.2] respectively. Experimental inoculations with different M. agalactiae strains revealed that the ELISA kits poorly detected the antibody response to certain strains. Furthermore, test performances varied according to the host species or geographical origin of the samples. Finally, the correlation between milk shedding of M. agalactiae and the presence of detectable antibodies in the blood was poor. Conclusions These serological tests are not interchangeable. The choice of a test will depend on the objectives (early detection of infection or disease control program), on the prevalence of infection and the control protocol used. Given the variety of factors that may influence performance, a preliminary assessment of the test in a given situation is recommended prior to widespread use. PMID:22776779
The EPA's National Risk Management Research Laboratory (NRMRL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Abraxis Ecologenia Ethynylestradiol (EE2) ...
Verification of ELISA Test Kits to Determine EDCs in Animal Feedlot Runoff
The key points discussed in this presentation are: (1) Climate change will very likely exacerbate the already stressed water supply in the U.S. Southeast, the only region that has experienced precipitation decline over >100 years; (2) The effect in precipitation change is locati...
Production of Bioactive Recombinant Bovine Chymosin in Tobacco Plants
Wei, Zheng-Yi; Zhang, Yu-Ying; Wang, Yun-Peng; Fan, Ming-Xia; Zhong, Xiao-Fang; Xu, Nuo; Lin, Feng; Xing, Shao-Chen
2016-01-01
Chymosin (also known as rennin) plays an essential role in the coagulation of milk in the cheese industry. Chymosin is traditionally extracted from the rumen of calves and is of high cost. Here, we present an alternative method to producing bovine chymosin from transgenic tobacco plants. The CYM gene, which encodes a preprochymosin from bovine, was introduced into the tobacco nuclear genome under control of the viral 35S cauliflower mosaic promoter. The integration and transcription of the foreign gene were confirmed with Southern blotting and reverse transcription PCR (RT-PCR) analyses, respectively. Immunoblotting analyses were performed to demonstrate expression of chymosin, and the expression level was quantified by enzyme-linked immunosorbent assay (ELISA). The results indicated recombinant bovine chymosin was successfully expressed at an average level of 83.5 ng/g fresh weight, which is 0.52% of the total soluble protein. The tobacco-derived chymosin exhibited similar native milk coagulation bioactivity as the commercial product extracted from bovine rumen. PMID:27136529
Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R
2018-06-01
Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
Verstraelen, Sandra; Maglennon, Gareth; Hollanders, Karen; Boonen, Francis; Adriaens, Els; Alépée, Nathalie; Drzewiecka, Agnieszka; Gruszka, Katarzyna; Kandarova, Helena; Willoughby, Jamin A; Guest, Robert; Schofield, Jane; Van Rompay, An R
2017-10-01
Assessment of ocular irritation potential is an international regulatory requirement in the safety evaluation of industrial and consumer products. None in vitro ocular irritation assays are capable of fully categorizing chemicals as stand-alone. Therefore, the CEFIC-LRI-AIMT6-VITO CON4EI consortium assessed the reliability of eight in vitro test methods and computational models as well as established a tiered-testing strategy. One of the selected assays was Bovine Corneal Opacity and Permeability (BCOP). In this project, the same corneas were used for measurement of opacity using the OP-KIT, the Laser Light-Based Opacitometer (LLBO) and for histopathological analysis. The results show that the accuracy of the BCOP OP-KIT in identifying Cat 1 chemicals was 73.8% while the accuracy was 86.3% for No Cat chemicals. BCOP OP-KIT false negative results were often related to an in vivo classification driven by conjunctival effects only. For the BCOP LLBO, the accuracy in identifying Cat 1 chemicals was 74.4% versus 88.8% for No Cat chemicals. The BCOP LLBO seems very promising for the identification of No Cat liquids but less so for the identification of solids. Histopathology as an additional endpoint to the BCOP test method does not reduce the false negative rate substantially for in vivo Cat 1 chemicals. Copyright © 2017 Elsevier Ltd. All rights reserved.
García-Lunar, P; Ortega-Mora, L M; Schares, G; Gollnick, N S; Jacquiet, P; Grisez, C; Prevot, F; Frey, C F; Gottstein, B; Alvarez-García, G
2013-02-01
Bovine besnoitiosis is considered an emerging chronic and debilitating disease in Europe. Many infections remain subclinical, and the only sign of disease is the presence of parasitic cysts in the sclera and conjunctiva. Serological tests are useful for detecting asymptomatic cattle/sub-clinical infections for control purposes, as there are no effective drugs or vaccines. For this purpose, diagnostic tools need to be further standardized. Thus, the aim of this study was to compare the serological tests available in Europe in a multi-centred study. A coded panel of 241 well-characterized sera from infected and non-infected bovines was provided by all participants (SALUVET-Madrid, FLI-Wusterhausen, ENV-Toulouse, IPB-Berne). The tests evaluated were as follows: an in-house ELISA, three commercial ELISAs (INGEZIM BES 12.BES.K1 INGENASA, PrioCHECK Besnoitia Ab V2.0, ID Screen Besnoitia indirect IDVET), two IFATs and seven Western blot tests (tachyzoite and bradyzoite extracts under reducing and non-reducing conditions). Two different definitions of a gold standard were used: (i) the result of the majority of tests ('Majority of tests') and (ii) the majority of test results plus pre-test information based on clinical signs ('Majority of tests plus pre-test info'). Relative to the gold standard 'Majority of tests', almost 100% sensitivity (Se) and specificity (Sp) were obtained with SALUVET-Madrid and FLI-Wusterhausen tachyzoite- and bradyzoite-based Western blot tests under non-reducing conditions. On the ELISAs, PrioCHECK Besnoitia Ab V2.0 showed 100% Se and 98.8% Sp, whereas ID Screen Besnoitia indirect IDVET showed 97.2% Se and 100% Sp. The in-house ELISA and INGEZIM BES 12.BES.K1 INGENASA showed 97.3% and 97.2% Se; and 94.6% and 93.0% Sp, respectively. IFAT FLI-Wusterhausen performed better than IFAT SALUVET-Madrid, with 100% Se and 95.4% Sp. Relative to the gold standard 'Majority of test plus pre-test info', Sp significantly decreased; this result was expected because of the existence of seronegative animals with clinical signs. All ELISAs performed very well and could be used in epidemiological studies; however, Western blot tests performed better and could be employed as a posteriori tests for control purposes in the case of uncertain results from valuable samples. © 2012 Blackwell Verlag GmbH.
Sridevi, N. V.; Shukra, A. M.; Neelakantam, B.; Anilkumar, J.; Madhanmohan, M.; Rajan, S.; Dev Chandran
2014-01-01
Recombinant antibody fragments like single chain variable fragments (scFvs) represent an attractive yet powerful alternative to immunoglobulins and hold great potential in the development of clinical diagnostic/therapeutic reagents. Structurally, scFvs are the smallest antibody fragments capable of retaining the antigen-binding capacity of whole antibodies and are composed of an immunoglobulin (Ig) variable light (VL) and variable heavy (VH) chain joined by a flexible polypeptide linker. In the present study, we constructed a scFv against bovine IgA from a hybridoma cell line IL-A71 that secretes a monoclonal antibody against bovine IgA using recombinant DNA technology. The scFv was expressed in Escherichia coli and purified using immobilized metal affinity chromatography (IMAC). The binding activity and specificity of the scFv was established by its non-reactivity toward other classes of immunoglobulins as determined by enzyme-linked immunosorbent assay (ELISA) and immunoblot analysis. Kinetic measurement of the scFv indicated that the recombinant antibody fragment had an affinity in picomolar range toward purified IgA. Furthermore, the scFv was used to develop a sensitive ELISA for the detection of foot and mouth disease virus (FMDV) carrier animals. PMID:24678404
Pan, Yu; Fisher, Taylor; Olk, Christina
2014-01-01
An enzyme-linked immunosorbent assay (ELISA) was developed to detect bovine antibodies to Histophilus somni exopolysaccharide (EPS), which is created during biofilm formation. When an index value of 0.268 was used, the sensitivity of the assay for infected calves was 90.5% at 3 weeks postinfection, but the number of positive animals increased by week 4. The specificity of the assay for healthy calves was 92.5%. The EPS ELISA may aid in identifying calves with H. somni diseases. PMID:25143338
Clavijo, A; Lin, M; Riva, J; Mallory, M; Lin, F; Zhou, E M
2001-02-01
The sequence encoding a truncated E2 glycoprotein of the Alfort/187 strain of classical swine fever virus (CSFV) was expressed in Escherichia coli using the pET expression system and the recombinant product purified by Ni-NTA agarose affinity chromatography. The antigenicity of this recombinant protein was demonstrated by immunoblot using anti- CSFV-specific antibodies. A monoclonal antibody was produced against the truncated E2 protein and used as competitor in an ELISA for the detection of antibodies to CSFV. Specific antibodies were demonstrated by competitive ELISA (C-ELISA) as early as 21 days post-infection (dpi) in experimentally infected pigs. Seroconversion was demonstrated by C-ELISA and neutralising peroxidase-linked assay (NPLA) in all infected animals by 4 weeks. No cross-reaction with antibodies to bovine viral diarrhoea virus (BVDV) was seen in the C-ELISA using sera from experimentally infected pigs. The C-ELISA is not intended as a substitute for the NPLA. However, it is expected it will be useful for monitoring and prevalence studies. It will also assist in testing a large number of samples in the event of an outbreak. Copyright 2001 Harcourt Publishers Ltd.
Larsen, Alejandra; Gonzalez, Ester Teresa; Serena, María Soledad; Echeverría, María Gabriela; Mortola, Eduardo
2013-06-01
Bovine leukemia is a common retroviral infection of cattle. The disease is characterized by a strong immunological response to several viral proteins, but the antibodies against p24 and gp51 are predominant. In this study, a recombinant baculovirus containing the gag gene p24 was constructed and the protein, used as antigen, analyzed by western blot and an indirect in-house rp24-ELISA test. This allowed detecting the presence of antibodies for bovine leukemia virus in a panel of cattle sera. The authentication of the protein expands its potential use for different medical applications, from improved diagnosis of the disease to source of antigens to be included in a subunit vaccine.
Gonzalez, A M; Arnaiz, I; Eiras, C; Camino, F; Sanjuán, M L; Yus, E; Diéguez, F J
2014-01-01
This study was designed to determine long-term responses in dairy herds after vaccination with 1 of 3 inactivated bovine viral diarrhea virus (BVDV) vaccines with regard to antibodies against p80 protein in bulk tank milk samples, as detected by ELISA. In the present study, 29 dairy herds were vaccinated with Bovilis BVD (MSD Animal Health, Milton Keynes, UK), 11 with Hiprabovis Balance (Laboratorios Hipra, Amer, Spain), and 9 with Pregsure BVD (Zoetis, Florham Park, NJ). In these herds, bulk tank milk samples were collected and examined at the time of the first vaccination and every 6 mo during a 3-yr period. Samples were analyzed with a commercial ELISA test for the p80 protein of BVDV. The results demonstrated that vaccination affected the level of antibodies against p80. Hence, vaccination status should be taken into consideration when interpreting bulk tank milk antibody tests. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Huet, Anne-Catherine; Charlier, Caroline; Deckers, Elise; Marbaix, Hélène; Raes, Martine; Mauro, Sergio; Delahaut, Philippe; Gillard, Nathalie
2016-11-30
The European Commission (EC) wants to reintroduce nonruminant processed animal proteins (PAPs) safely into the feed chain. This would involve replacing the current ban in feed with a species-to-species ban which, in the case of nonruminants, would only prohibit feeding them with proteins from the same species. To enforce such a provision, there is an urgent need for species-specific methods for detecting PAPs from several species in animal feed and in PAPs from other species. Currently, optical microscopy and the polymerase chain reaction are the officially accepted methods, but they have limitations, and alternative methods are needed. We have developed immunoassays using antibodies raised against targets which are not influenced by high temperature and pressure. These targets were identified in a previous study based on an experimental approach. One optimized competitive ELISA detects bovine PAPs at 2% in plant-derived feed. The detection capability demonstrated on blind samples shows a good correlation with mass spectrometry results.
Hochegger, Rupert; Mayer, Walter; Prochaska, Manuela
2015-01-01
Celiac Disease (CD) is one of the most common food intolerances. It comes along with serious damage of the mucosa in the small intestine and is caused by the storage proteins—termed “gluten”—of wheat, rye, barley and possibly oats. Sensitive individuals need to stick to a strict gluten-free diet. The gluten level in food products labeled as “gluten-free”, must not exceed 20 mg/kg. It is obvious that effective test methods are needed to accurately determine the gluten concentration in foods. The determination of the presence of gluten in foodstuffs is mainly done by means of an immunochemical method called ELISA (enzyme-linked immunosorbent assay). To check the suitability of a G12 antibody-based gluten detection kit for its use in official control systems a number of routine samples were tested in parallel with two different test kits, as would be done in a routine lab. The determination of the gluten content was performed on samples entering the official laboratory including samples from official control plans, commercially available and private samples to request gluten-free labels. The results obtained with the G12 antibody ELISA assay were comparable to the official R5 method. A validation of the two different methods was not part of this study. PMID:28231228
Wasniewski, M; Almeida, I; Baur, A; Bedekovic, T; Boncea, D; Chaves, L B; David, D; De Benedictis, P; Dobrostana, M; Giraud, P; Hostnik, P; Jaceviciene, I; Kenklies, S; König, M; Mähar, K; Mojzis, M; Moore, S; Mrenoski, S; Müller, T; Ngoepe, E; Nishimura, M; Nokireki, T; Pejovic, N; Smreczak, M; Strandbygaard, B; Wodak, E; Cliquet, F
2016-12-01
The most effective and sustainable method to control and eliminate rabies in wildlife is the oral rabies vaccination (ORV) of target species, namely foxes and raccoon dogs in Europe. According to WHO and OIE, the effectiveness of oral vaccination campaigns should be regularly assessed via disease surveillance and ORV antibody monitoring. Rabies antibodies are generally screened for in field animal cadavers, whose body fluids are often of poor quality. Therefore, the use of alternative methods such as the enzyme-linked immunosorbent assay (ELISA) has been proposed to improve reliability of serological results obtained on wildlife samples. We undertook an international collaborative study to determine if the commercial BioPro ELISA Rabies Ab kit is a reliable and reproducible tool for rabies serological testing. Our results reveal that the overall specificity evaluated on naive samples reached 96.7%, and the coefficients of concordance obtained for fox and raccoon dog samples were 97.2% and 97.5%, respectively. The overall agreement values obtained for the four marketed oral vaccines used in Europe were all equal to or greater than 95%. The coefficients of concordance obtained by laboratories ranged from 87.2% to 100%. The results of this collaborative study show good robustness and reproducibility of the BioPro ELISA Rabies Ab kit. Copyright © 2016 Elsevier B.V. All rights reserved.
Martínez-Torrecuadrada, Jorge L.; Lázaro, Beatriz; Rodriguez, José F.; Casal, J. Ignacio
2000-01-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions. PMID:10882666
Martínez-Torrecuadrada, J L; Lázaro, B; Rodriguez, J F; Casal, J I
2000-07-01
The routine technique for detecting antibodies specific to infectious bursal disease virus (IBDV) is a serological evaluation by enzyme-linked immunosorbent assay (ELISA) with preparations of whole virions as the antigens. To avoid using complete virus in the standard technique, we have developed two new antigens through the expression of the VPX and VP3 genes in insect cells. VPX and especially VP3 were expressed at high levels in insect cells and simple to purify. The immunogenicity of both proteins was similar to that of the native virus. VPX was able to elicit neutralizing antibodies but VP3 was not. Purified VPX and VP3 were tested in an indirect ELISA with more than 300 chicken sera. There was an excellent correlation between the results of the ELISA using VPX and those of the two commercial kits. VP3 did not perform as well as VPX, and the linear correlation was significantly lower. A comparison with the standard reference technique, seroneutralization, showed that the indirect ELISA was more sensitive. Therefore, VPX-based ELISA is a good alternative to conventional ELISAs that use whole virions.
Song, Ming-Fen; Li, Yun-Shan; Ootsuyama, Yuko; Kasai, Hiroshi; Kawai, Kazuaki; Ohta, Masanori; Eguchi, Yasumasa; Yamato, Hiroshi; Matsumoto, Yuki; Yoshida, Rie; Ogawa, Yasutaka
2009-07-01
Urinary 8-OH-dG is commonly analyzed as a marker of oxidative stress. For its analysis, ELISA and HPLC methods are generally used, although discrepancies in the data obtained by these methods have often been discussed. To clarify this problem, we fractionated human urine by reverse-phase HPLC and assayed each fraction by the ELISA method. In addition to the 8-OH-dG fraction, a positive reaction was observed in the first eluted fraction. The components in this fraction were examined by the ELISA. Urea was found to be the responsible component in this fraction. Urea is present in high concentrations in the urine of mice, rats, and humans, and its level is influenced by many factors. Therefore, certain improvements, such as a correction based on urea content or urease treatment, are required for the accurate analysis of urinary 8-OH-dG by the ELISA method. In addition, performance of the ELISA at 4 degrees C reduced the recognition of urea considerably and improved the 8-OH-dG analysis.
Quinet, Christian; Czaplicki, Guy; Dion, Elise; Dal Pozzo, Fabiana; Kurz, Anke; Saegerman, Claude
2016-01-01
Background Infection due to bovine viral diarrhoea virus (BVDV) is endemic in most cattle-producing countries throughout the world. The key elements of a BVDV control programme are biosecurity, elimination of persistently infected animals and surveillance. Bovine viral diarrhoea (BVD) is a notifiable disease in Belgium and an official eradication programme started from January 2015, based on testing ear notches sampled during the official identification and registration of calves at birth. An antigen-capture ELISA test based on the detection of BVDV Erns protein is used. Ear notch sample may also be used to characterize the genotype of the calf when appropriate elution/dilution buffer is added. Both BVDV antigen-ELISA analysis and animal traceability could be performed. Methodology With regards to the reference protocol used in the preparation of ear notch samples, alternative procedures were tested in terms of BVDV analytic sensitivity, diagnostic sensitivity and specificity, as well as quality and purity of animal DNA. Principal Findings/Significance The Allflex DNA Buffer D showed promising results in BVDV diagnosis and genome analyses, opening new perspectives for the livestock industry by the exploitation of the animal genome. Due to the high number of cattle involved in the Belgian official BVDV eradication programme based on ear notch tags sample, a large database on both BVDV status of newborn calves and cattle genome could be created for subsequent different uses (e.g. traceability, determination of parentage, genetic signatures throughout the genome associated with particular traits) evolving through a more integrated animal health. PMID:27764130
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mirshahi, M., E-mail: massoud.mirshahi@inserm.fr; Le Marchand, S.
Aim: Previously, we reported that visual arrestin co-purified with glycolytic enzymes. The aim of this study was to analyze the co-purification of arrestin like proteins (ALP) in bovine cardiac tissues with enolases. Methods: The soluble extract of bovine myocardial tissues from different regions such as left and right atriums and ventricles of the bovine heart (n = 3) was analyzed by ACA-34 gel filtration, immuno-affinity column, SDS-PAGE, ELISA, western blot and a sandwich immune assay for quantification of ALP and sequence analysis. Results: We observed that; 1) The cardiac muscle contained a 50 kDa ALP at a concentration of 751 pg/mg of soluble proteinmore » extract, 2) ALP purified, by immunoaffinity, contained alpha-enolase of 48 kDa confirmed by protein sequence analysis; 3) Cardiomyocyte cells exposed to anti arrestin and anti enolase monoclonal antibodies showed decreased proliferation in vitro, 4) High level of autoantibodies were detected by ELISA (3.57% for arrestin and 9.12% for α-enolase) in serum of patients with infarcted heart disease. Conclusion: We suggest a possible interaction between ALP and alpha-enolases yielding a complex that may be involved in the induction of cardiac autoimmune diseases. - Highlights: • We examine a possible interaction between arrestin like protein and alpha-enolases in cardiomyocyte. • We demonstrated the effect of antibodies against arrestin and enolase on cardiomyocyte cell proliferation. • We suggest that this proteins complex may be involved in the induction of cardiac autoimmune diseases.« less
Rodrigues, Valérie; Baudier, Jean Baptiste; Chantal, Isabelle
2017-09-01
Quantifying cytokines is extremely important in studies of host-pathogen interactions. Multiplex assays are commercially available but only for human and mouse cytokines. Here a method for the simultaneous quantification of five important bovine cytokines IFNγ, IL-4, IL-10, IL-12, and TNFα in cell culture supernatants, using flow cytometry was reported. Functional beads from BD Biosciences expressing specific APC intensity were used. Commercially available antibodies against bovine cytokines were covalently coupled to beads as capture antibodies. Fixed recombinant cytokines were revealed with a second monoclonal antibody coupled with biotin, then revealed with streptavidin-PE. This complex was analyzed using a standard flow cytometer. Experiments were performed to check no cross reactions had occurred. The limits of detection ranged between 0.08 and 0.4 ng/ml depending on the cytokine, and the linearity between the lower and higher limits was remarkable (R 2 > 99.8%). Finally, native cytokines from cell culture supernatants were tested. Results were compared using the standard ELISA test and showed that concentrations of native cytokine in cell culture supernatants were comparable with the two methods, with a wider dynamic range using beads and flow cytometry than with ELISA assays. Bovine IFNγ, IL-4, IL-10, IL-12, and TNFα in culture supernatants can be now simultaneously detected in a single assay, using a standard flow cytometer for both basic and high-throughput analyses. © 2017 International Society for Advancement of Cytometry. © 2017 International Society for Advancement of Cytometry.
The EPA's National Risk Management Research Laboratory (NRMRL) and its verification organization partner, Battelle, operate the Advanced Monitoring Systems (AMS) Center under ETV. The AMS Center recently evaluated the performance of the Abraxis 17(beta)-estradiol (E2) magnetic p...
Evaluation of commercial a-amylase enzyme-linked immunosorbent assy (ELISA) test kits for wheat
USDA-ARS?s Scientific Manuscript database
a-Amylase enzyme is associated with preharvest sprouting (PHS) and late-maturity a amylase (LMA) in wheat, and reduces wheat and flour quality. Various means have been developed to measure the presence of a-amylase, thereby predicting end-use quality; most are based on enzyme activity. An alternativ...
A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation ...
Deneke, Yosef; Sabarinath, T; Gogia, Neha; Lalsiamthara, Jonathan; Viswas, K N; Chaudhuri, Pallab
2014-08-01
Leptospirosis is a zoonotic disease caused by pathogenic spirochetes of the genus Leptospira, causing febrile infection characterized by multi-organ failure in humans and animals. Leptospiral Ig-like protein B (LigB) is a surface-expressed antigen that mediates host cell invasion or attachment. In this study, N-terminal conserved region of LigB protein (46 kDa) was evaluated for its diagnostic potential to detect anti-leptospiral antibodies in the sera of various animal species. Dot blot analysis revealed immunoreactivity of Leptospira-positive sera of cattle, buffalo, dog, sheep and goat to purified LigB protein. We have analyzed 1126 bovine serum samples, collected from Northern and Eastern part of India, by microscopic agglutination test (MAT) and recombinant LigB (rLigB) based ELISA and latex agglutination test (LAT). The sensitivity of rLigB based ELISA for 554 MAT positive sera was 96.9% and the specificity with 572 MAT negative sera was 91.08% whereas LAT showed sensitivity and specificity of 93.68% and 92.31%, respectively. Kappa values of 0.879 and 0.860 for recombinant antigen based ELISA and LAT indicate excellent agreement with the gold standard serological test, MAT, for the detection of anti-leptospiral antibodies in sera. Further, LAT based on rLigB antigen is a simple and rapid test, suitable for serodiagnosis of leptospirosis under field conditions, owing to its portability and longer shelf life. Copyright © 2014 Elsevier Ltd. All rights reserved.
Jansen, Famke; Dorny, Pierre; Berkvens, Dirk; Van Hul, Anke; Van den Broeck, Nick; Makay, Caroline; Praet, Nicolas; Eichenberger, Ramon Marc; Deplazes, Peter; Gabriël, Sarah
2017-09-15
Bovine cysticercosis (BCC), caused by the helminth Taenia saginata, is currently diagnosed solely by official meat inspection (MI) based on macroscopic detection of viable cysticerci or typical lesions of degenerated larvae. MI has a known low sensitivity (<16%), leading to a large proportion of infected cattle carcasses entering the human food chain and posing a risk to public health. Prevalence in Belgium based on MI results is estimated at around 0.22%. Due to the low sensitivity of MI, alternative techniques to detect BCC should be considered. This study evaluates MI, MI with additional incisions in the heart, specific antibody detection against excretory/secretory (E/S) in the Ab-ELISA and circulating antigens in the B158/B60 Ag-ELISA on 715 (101 MI-positive and 614 MI-negative) samples collected from carcasses at slaughterhouses in Belgium. Full dissection of the predilection sites was considered the reference test. During the study, mostly carcasses with (very) light infections were detected containing predominantly degenerated or calcified cysticerci and only few viable cysticerci. Dissection of the predilection sites detected 144 (23%) additional infections in the 614 MI-negative carcasses. When sequentially performing first the dissection of the predilection sites, followed by the Ag-ELISA and the Ab-ELISA, an additional 36% of MI-negative carcasses were found positive for BCC, resulting in a prevalence very much higher than the above mentioned 0.22%. The B158/B60 Ag-ELISA showed a sensitivity of 40% for the detection of carcasses containing viable cysticerci and a specificity of 100%, and detected 70 positive carcasses of which only 14 had been identified as positive during MI. If Ag-ELISA were implemented as a detection technique for BCC in the slaughterhouses, many infected carcasses would still not be detected due to the sensitivity of 40%. But as sensitivity increases with increasing number of cysticerci in the carcass, the infected carcasses passing inspection will be the ones containing only a few viable cysticerci and thus posing a smaller food safety problem. Ag-ELISA is preferred over the ES Ab-ELISA in this study, which had a sensitivity of 13.3% and a specificity of 91.7% in a population with overall low infection burdens. Copyright © 2017 Elsevier B.V. All rights reserved.
Altrich, Michelle L.; Nowicki, Marek J.
2016-01-01
The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. PMID:27535838
Cho, H J; Entz, S C; Magar, R; Joo, H S
1997-01-01
Porcine reproductive and respiratory syndrome virus (PRRSV) ELISA antigens of high quality were produced using 8 different isolates of PRRSV: the European Lelystad virus (LV), the U.S. MN-1b, 89-46448, 93-44927, and 93-24025B, and the Canadian LHVA-93-3, PA-8 and GH-6 virus isolates. The performance of each of these 8 antigens and a commercial PRRSV antibody test kit (Idexx's HerdChek) were measured against antisera raised in 5 groups of 6 piglets inoculated with either LV, MN-1b, 89-46448, 93-44927, or 93-24025B. Among the 8 isolates, the 89-46448 isolate produced the broadest spectrum of antigen and resulted in earlier detection of antibodies to various North American PRRSV isolates, followed by MN-1b as the 2nd best ELISA antigen for the detection of North American PRRSV antibodies. The GH-6 and PA-8 viral antigens exhibited restricted detection of PRRSV antibodies. The LV and 89-46448 combined antigens produced the best performance for the detection of antibodies against both European and North American antigenic types of PRRSV. Using 173 panel samples collected at 11 to 60 d after intranasal inoculation with 1 of the 5 PRRSV isolates, the sensitivities of the indirect ELISA used were 73.4%, 98.3%, 90.8%, 98.3%, 83.2%, 93.1%, 77.1%, 64.2%, 98.8% and 95.9% for LV, MN-1b, LHVA-93-3, 89-46448, 93-44927, 93-24025B, PA-8, GH-6 antigens, 89-46448-LV combined antigens and Idexx's PRRSV antibody test kit, respectively. All 8 antigens gave negative results with preinfection porcine sera (n = 30); high background or nonspecific reactions were not observed with the antigens. PMID:9342455
Validation of an ELISA Synthetic Cannabinoids Urine Assay.
Barnes, Allan J; Spinelli, Eliani; Young, Sheena; Martin, Thomas M; Kleete, Kevin L; Huestis, Marilyn A
2015-10-01
Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug-testing laboratories. We evaluated performance of the National Medical Services (NMS) JWH-018 direct enzyme-linked immunosorbent assay (ELISA) kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was used to screen 2492 urine samples with 5 and 10 mcg/L cutoffs. A fully validated liquid chromatography-tandem mass spectrometry method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25% and ±50% of cutoffs determined intraplate and interplate imprecision around proposed cutoffs. The immunoassay was linear from 1 to 500 mcg/L with intraplate and interplate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, coadministered drugs, over-the-counter medications, or structurally similar compounds, and 19 of 73 individual synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4%, and 97.6%, as well as 71.6%, 99.7%, and 96.4% with the 5 and 10 mcg/L urine cutoffs, respectively. This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5 mcg/L urine cutoff.
Validation of an ELISA Synthetic Cannabinoids Urine Assay
Barnes, Allan J.; Spinelli, Eliani; Young, Sheena; Martin, Thomas M.; Klette, Kevin L.; Huestis, Marilyn A.
2015-01-01
Background Synthetic cannabinoids are touted as legal alternatives to cannabis, at least when first released, and routine urine cannabinoid screening methods do not detect these novel psychoactive substances. Synthetic cannabinoids are widely available, are a major public health and safety problem, and a difficult challenge for drug testing laboratories. We evaluated performance of the NMS JWH-018 direct ELISA kit to sensitively, selectively, and rapidly screen urinary synthetic cannabinoids. Materials/ Methods The NMS ELISA kit targeting the JWH-018 N-(5-hydroxypentyl) metabolite was utilized to screen 2492 urine samples with 5 and 10µg/L cutoffs. A fully validated LC-MS/MS method for 29 synthetic cannabinoids markers confirmed all presumptive positive and negative results. Performance challenges at ±25 and ±50% of cutoffs determined intra- and inter-plate imprecision around proposed cutoffs. Result The immunoassay was linear from 1–500µg/L with intra- and inter-plate imprecision of ≤8.2% and <14.0%, respectively. No interferences were present from 93 common drugs of abuse, metabolites, co-administered drugs, over-the-counter medications or structurally similar compounds, and 19 of 73 individual, synthetic cannabinoids (26%) exhibited moderate to high cross-reactivity to JWH-018 N-(5-hydroxypentyl) metabolite. Sensitivity, specificity, and efficiency results were 83.7%, 99.4% and 97.6% and 71.6%, 99.7% and 96.4%, with the 5 and 10µg/L urine cutoffs, respectively. Conclusion This high throughput immunoassay exhibited good diagnostic efficiency and documented that the NMS JWH-018 direct ELISA is a viable method for screening synthetic cannabinoids in urine targeting the JWH-018 N-(5-hydroxypentyl) and related analytes. Optimal performance was achieved with a matrix-matched 5µg/L urine cutoff. PMID:25706046
Thuróczy, Julianna; Reiczigel, Jenő; Balogh, Lajos
2016-09-01
Twenty-two serum samples of healthy bitches were tested with the frozen and lyophilised version of the same ELISA kit (Quanticheck, Faculty of Veterinary Science, Budapest, Hungary). Samples were chosen on the basis of their progesterone (P4) concentrations, which were between 1.00 and 20.00 ng/mL. As it is well known, this range has the highest clinical relevance in ovulation diagnosis. Both types of microplates were read at 15-min intervals from the 15th until the 90th minute (min) of incubation, and the results were compared with those of frozen plates at 60 min of incubation as 100 percent. Lyophilised microplates gave on average 18 percent higher results than the frozen version at equal incubation times. The highest difference between lyophilised and frozen samples was observed at 45 and 60 min of incubation. Ninety-four percent of the reaction in the frozen microplate occurred in the first 15 min, and during the subsequent 30 min the reaction seemingly stopped. After the 45th min of incubation, this 94 percent increased to 108 percent in the subsequent 30 min, which remained the final approximate result at the end of the 90 min of incubation. In contrast to the frozen microplate, the measured concentration increased continuously in the lyophilised version and reached the highest level at the 60th min. The results of the lyophilised microplate reached the same level at 30 min of incubation as those of the frozen version at 60 min. In conclusion, a mechanical increase or decrease of the incubation time does not generate a linear change in the test results. This study demonstrated that the results of a series of samples collected from the same bitch cannot be compared if they are measured with different laboratory methods or different ELISA kits.
DEMONSTRATION AND QUALITY ASSURANCE PROJECT ...
The demonstration of technologies for determining the presence of dioxin in soil and sediment is being conducted under the U.S. Environmental Protection Agency Superfund Innovative Technology Evaluation Program in Saginaw, Michigan, at Green Point Environmental Learning Center from approximately April 26 to May 6, 2004. The primary purpose of the demonstration is to evaluate innovative monitoring technologies. The technologies listed below will be demonstrated. .AhRC PCRTM Kit, Hybrizyme Corporation .Ah-IMMUNOASSY@ Kit, Paralsian, Inc. .Coplanar PCB Immunoassay Kit, Abraxis LLC .DF-l Dioxin/Furan Immunoassay Kit, CAPE Technologies L.L.C. .CALUX@ by Xenobiotic Detection Systems, Inc- .Dioxin ELISA Kit, Wako Pure Chemical Industries LTD. This demonstration plan describes the procedures that will be used to verify the performance and cost of these technologies. The plan incorporates the quality assurance and quality control elements needed to generate data of sufficient quality to document each technology's performance and cost. A separate innovative technology verification report (ITVR) will.be prepared for each technology. The ITVRs will present the demonstration findings associated with the demonstration objectives. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Saidi, Radhwane; Bessas, Amina; Bitam, Idir; Ergün, Yaşar; Ataseven, Veysel Soydal
2018-03-01
This study was performed to investigate the presence of bovine herpesvirus-1 (BHV-1), bovine leukemia virus (BLV) and bovine viral diarrhea virus (BVDV) infections in dromedary camels (Camelus dromaderius) kept in mixed herds with sheep and goats in Algeria, since the prevalence of BHV-1, BVDV, and BLV infections among dromedary camels in Algeria is unknown. Totally, 111 camel sera were collected from two provinces (Laghouat and Ghardaia) in Algeria. The sera were analyzed for BHV-1 specific antibodies, BVDV specific antibodies and BVDV antigen using the ELISA, and BLV nucleic acid using PCR. The seropositivity rate was 9.0% for BVDV-specific antibody, although 41.4% of camels tested were positive for BVDV antigen. Moreover, there was no evidence of BHV-1 and BLV infections. The results indicated that camels might represent an important source for BVDV infection in all ruminants, including cattle, sheep, and goats bred in mixed herds in Algeria, since they had a higher BVDV prevalence rates. Therefore, the prevention and control measures for BVDV infection should put in place in camel populations to limit the spread of BVDV infection to ruminant populations in Algeria.
Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.
Xie, Zhen-ming; Yu, Lin; Fang, Li-sha
2015-01-01
The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.
Myers, Michael J; Yancy, Haile F; Araneta, Michael; Armour, Jennifer; Derr, Janice; Hoostelaere, Lawrence A D; Farmer, Doris; Jackson, Falana; Kiessling, William M; Koch, Henry; Lin, Huahua; Liu, Yan; Mowlds, Gabrielle; Pinero, David; Riter, Ken L; Sedwick, John; Shen, Yuelian; Wetherington, June; Younkins, Ronsha
2006-01-01
A method trial was initiated to validate the use of a commercial DNA forensic kit to extract DNA from animal feed as part of a PCR-based method. Four different PCR primer pairs (one bovine pair, one porcine pair, one ovine primer pair, and one multispecies pair) were also evaluated. Each laboratory was required to analyze a total of 120 dairy feed samples either not fortified (control, true negative) or fortified with bovine meat and bone meal, porcine meat and bone meal (PMBM), or lamb meal. Feeds were fortified with the animal meals at a concentration of 0.1% (wt/wt). Ten laboratories participated in this trial, and each laboratory was required to evaluate two different primer pairs, i.e., each PCR primer pair was evaluated by five different laboratories. The method was considered to be validated for a given animal source when three or more laboratories achieved at least 97% accuracy (29 correct of 30 samples for 96.7% accuracy, rounded up to 97%) in detecting the fortified samples for that source. Using this criterion, the method was validated for the bovine primer because three laboratories met the criterion, with an average accuracy of 98.9%. The average false-positive rate was 3.0% in these laboratories. A fourth laboratory was 80% accurate in identifying the samples fortified with bovine meat and bone meal. A fifth laboratory was not able to consistently extract the DNA from the feed samples and did not achieve the criterion for accuracy for either the bovine or multispecies PCR primers. For the porcine primers, the method was validated, with four laboratories meeting the criterion for accuracy with an average accuracy of 99.2%. The fifth laboratory had a 93.3% accuracy outcome for the porcine primer. Collectively, these five laboratories had a 1.3% false-positive rate for the porcine primer. No laboratory was able to meet the criterion for accuracy with the ovine primers, most likely because of problems with the synthesis of the primer pair; none of the positive control DNA samples could be detected with the ovine primers. The multispecies primer pair was validated in three laboratories for use with bovine meat and bone meal and lamb meal but not with PMBM. The three laboratories had an average accuracy of 98.9% for bovine meat and bone meal, 97.8% for lamb meal, and 63.3% for PMBM. When examined on an individual laboratory basis, one of these four laboratories could not identify a single feed sample containing PMBM by using the multispecies primer, whereas the other laboratory identified only one PMBM-fortified sample, suggesting that the limit of detection for PMBM with this primer pair is around 0.1% (wt/wt). The results of this study demonstrated that the DNA forensic kit can be used to extract DNA from animal feed, which can then be used for PCR analysis to detect animal-derived protein present in the feed sample.
Chisi, Songelwayo L; Marageni, Yoanda; Naidoo, Prebashni; Zulu, Gloria; Akol, George W; Van Heerden, Henriette
2017-02-28
The diagnostic sensitivity (DSe) of the Rose Bengal test (RBT), the complement fixation test (CFT), the serum agglutination test (SAT), the competitive enzyme-linked immunosorbent assay (cELISA) and the indirect ELISA (iELISA) were determined in naturally infected cattle in KwaZulu-Natal province of South Africa with known infectious status from culture (gold standard). Natural brucellosis infection status of animals was determined by culturing and identification of Brucella abortus biovar 1 from abomasal fluid, milk, hygroma fluid, lymph nodes or uterine discharges samples. The diagnostic specificity (DSp) of the tests mentioned above was determined using samples from known negative herds. There was no statistically significant difference between the tests in their ability to diagnose brucellosis. The RBT and iELISA had the highest DSe of 95.8%, whereas RBT and CFT had the highest DSp of 100%. In South African laboratories, the RBT and CFT serological tests are used, because of the cost efficacy of CFT when compared to the less labour intensive but more expensive iELISA.
Wang, Youmei; Lu, Minghua; Tang, Dianping
2018-06-30
A new photoluminescence (PL) enzyme immunoassay was designed for sensitive detection of aflatoxin B 1 (AFB 1 ) via an innovative enzyme substrate, 6-aza-2-thiothymine-stabilized gold nanocluster (AAT-AuNC) with L-arginine. The enzyme substrate with strong PL intensity was formed through supramolecular host-guest assembly between guanidine group of L-arginine and AAT capped on the surface of AuNC. Upon arginase introduction, the captured L-arginine was hydrolyzed into ornithine and urea, thus resulting in the decreasing PL intensity. Based on this principle, a novel competitive-type immunoreaction was first carried out on AFB 1 -bovine serum albumin (AFB 1 -BSA) conjugate-coated microplate, using arginase-labeled anti-AFB 1 antibody as the competitor. Under the optimum conditions, the PL intensity increased with the increment of target AFB 1 , and allowed the detection of the analyte at concentrations as low as 3.2 pg mL -1 (ppt). Moreover, L-arginine-AAT-AuNC-based PL enzyme immunoassay afforded good reproducibility and acceptable specificity. In addition, the accuracy of this methodology, referring to commercial AFB 1 ELISA kit, was evaluated to analyze naturally contaminated or spiked peanut samples, giving well-matched results between two methods, thus representing a useful scheme for practical application in quantitative monitoring of mycotoxins in foodstuff. Copyright © 2018 Elsevier B.V. All rights reserved.
Padmaja, Radhakrishnan Jayasree; Halami, Prakash Motiram
2016-09-01
Leukotoxin M/F'-PV (LukM/F'-PV) produced by bovine mastitis causing Staphylococcus aureus structurally comprises three domains, the β-sandwich, rim and stem domain. The rim and stem domains interacting with target cell membrane lipid rafts contributes to the virulent trait of the toxin. In the present study, two facts were hypothesized that neutralization of these domains will ebb LukM/F'-PV leukotoxicity. Secondly, the neutralizing antibodies can improve the leukotoxin detection sensitivity in bovine mastitis milk samples. The in silico mapping of S. aureus LukM C-termini comprising these domains predicted seven linear B-cell antigenic epitopes. The immune response of C-terminal truncated recombinant peptides rCtM19 (19 kDa; near carboxy-terminal) having four epitopes and rCtM15 (15 kDa; C-terminal) with three epitopes were evaluated for their diagnostic and neutralization potential. Anti-rCtM19 and anti-rCtM15 antibodies with enhanced immunogenicity had the most striking outcome in IgG-ELISA for detecting native determinants of leukotoxin. For the obtained ELISA values, ROC curve inferred a cut-off score of >0.102 OD405. The assay sensitivity in the range of 90-96% along with 100% specificity and AUC of 0.93-0.98 categorized subclinical and clinical from healthy bovine milk samples. As observed through in vitro neutralization and LDH assays, C-terminus specific antibodies (1:42 titer) deactivating leukotoxicity abolished LukM from interacting with lipid bilayer and LukF for forming pores on bovine neutrophil membrane. As a proof of concept, it was proved that peptide antibodies can be a more specific serodiagnostic and passive therapeutic molecules. Copyright © 2016 Elsevier Ltd. All rights reserved.
Development of an interleukin (IL)-33 sandwich ELISA kit specific for mature IL-33.
Kim, Eunsom; Kwak, Areum; Jhun, Hyunjhung; Lee, Siyoung; Jo, Seunghyun; Lee, Jongho; Kang, Tae-Bong; Her, Erk; Bae, Suyoung; Lee, Youngmin; Kim, Soohyun
2016-01-01
Interleukin (IL)-33 is an inflammatory cytokine and belongs to the IL-1 family of cytokines. There are eleven members of the IL-1 family of cytokines and all have important roles in host defense against infections. Their levels are increased during infection and in various auto-inflammatory diseases. IL-33 is also associated with autoimmune diseases such as asthma, atopic dermatitis, rheumatoid arthritis, and atherosclerosis. IL-33 receptors consist of IL-1R4 and IL-1R3 to induce both Th1 and Th2 type immune response. Here we present the development of monoclonal antibodies (mAbs) against human mature IL-33. Recombinant human mature IL-33 protein was expressed in E. coli and purified by multi-step affinity chromatography. The human IL-33 activity was examined in HMC-1 and Raw 264.7 cells. Mice were immunized with the biologically active mature IL-33 to generate mAb against IL-33. The anti-IL-33 mAb (clone/4) was used as a capture antibody for a sandwich enzyme-linked immunosorbent assay (ELISA). This assay detects mature IL-33 with a high sensitivity (80 pg/mL) but does not recognize the biologically inactive precursor IL-33. This article describes the methods for a newly developed IL-33 ELISA kit that is specific for mature IL-33 and may be used to analyze bioactive mature IL-33 in various immunological diseases.
Mosadeghi, Parvin; Heydari-Zarnagh, Hafez
2018-04-01
We aimed to develope a peptide-based indirect ELISA to detect antibodies against Human T-lymphotropic virus type I (HTLV-I). Two chimeric peptides (CP-1 and CP-2) were designed using linear immunodominant epitopes of gp-46-I, and gp21-I proteins, according to the sequence from Uniprot database. These peptides were studied initially in the ELISA using infected sera. The most promising peptideCP-1, was used to develop a peptide ELISA for detection of HTLV-I infected sera. The optimal conditions for CP-1ELISA were: the optimum coating buffer was 100mM NaHCO3, pH 9.6; coating peptide concentration was 10 µg/mL; the optimal blocking buffer was5% fetal bovine serum (FBS); the secondary antibody concentration was 1:2000; and serum dilution was 1:20. 20serum samples from HTLV-I infected patients were evaluated by ELISA developed. CP-1 showed high antigenicity while lacking any cross-reactivity with normal human sera. The results of evaluations indicated that in comparison with commercial ELISA, CP-1 ELISA showed good sensitivity and specificity. With further validation, CP-1as described in the present study could be introduced as novel reliable and cost-effective candidates for the high-specific screening of HTLV-I/-II infections in endemic regions.
Takeuchi-Storm, Nao; Denwood, Matthew; Hansen, Tina Vicky Alstrup; Halasa, Tariq; Rattenborg, Erik; Boes, Jaap; Enemark, Heidi Larsen; Thamsborg, Stig Milan
2017-11-09
The prevalence of bovine fasciolosis in Denmark is increasing but appropriate guidelines for control are currently lacking. In order to help develop a control strategy for liver fluke, a risk factor study of farm management factors was conducted and the utility of bulk tank milk (BTM ELISA) as a tool for diagnosis in Danish dairy cattle farms was assessed. This case-control study aimed to identify farm-level risk factors for fasciolosis in Danish dairy farms (> 50 animals slaughtered in 2013) using two diagnostic methods: recordings of liver condemnation at slaughter, and farm-level Fasciola hepatica antibody levels in BTM. A case farm was defined as having a minimum of 3 incidents of liver condemnation due to liver fluke at slaughter (in any age group) during 2013, and control farms were located within 10 km of at least one case farm and had no history of liver condemnation due to liver fluke during 2011-2013. The selected farmers were interviewed over telephone about grazing and control practices, and BTM from these farms was collected and analysed by ELISA in 2014. The final complete dataset consisting of 131 case and 63 control farms was analysed using logistic regression. Heifers grazing on wet pastures, dry cows grazing on wet pastures, herd size, breed and concurrent beef cattle production were identified as risk factors associated with being classified as a case farm. With the categorised BTM ELISA result as the response variable, heifers grazing on wet pastures, dry cows grazing on wet pastures, and purchase of cows were identified as risk factors. Within the case and control groups, 74.8 and 12.7% of farms were positive for fasciolosis on BTM ELISA, respectively. The differences are likely to be related to the detection limit of the farm-level prevalence by the BTM ELISA test, time span between slaughter data and BTM, and the relatively low sensitivity of liver inspection at slaughter. Control of bovine fasciolosis in Denmark should target heifers and dry cows through grazing management and appropriate anthelmintic treatment, and BTM ELISA can be a useful diagnostic tool for fasciolosis in Danish dairy farms.
Yang, Y; Fan, W; Mao, Y; Yang, Z; Lu, G; Zhang, R; Zhang, H; Szeto, C; Wang, C
2016-05-01
The main objective of this study was to investigate the individual cow effect of bovine leukemia virus (BLV) infection on milk production and somatic cell score (SCS). The fluorescence resonance energy transfer (FRET) quantitative PCR established in this study and a commercial ELISA kit revealed that 49.1% of dairy cattle (964/1,963) from 6 provinces of China and 1.6% of beef cattle (22/1,390) from 15 provinces were BLV positive. In a detailed study of 105 cows, BLV was found most commonly in buffy coat samples that also had highest copy numbers (10(4.75±1.56) per mL); all cows negative for BLV in buffy coat samples were also negative in vaginal swab, milk, and fecal samples. Copy numbers of BLV were 10(2.90±0.42)/gram of feces, 10(0.83±0.62)/mL of milk, and 10(2.18±0.81) per vaginal swab. The BLV-positive cows had significantly lower milk production in the early (26.8 vs. 30.9kg) and middle stages of lactation (22.2 vs. 26.1kg) in animals with ≥4 parities than the BLV-negative cows; they also had significantly higher SCS in early and middle lactation stages (early=5.2 vs. 4.3; middle=4.9 vs. 3.9) in animals with ≥4 parities. Milk production and SCS did not significantly differ between the BLV-infected and -uninfected cows when they were in the late lactation stage or in animals with ≤3 parities. Taken together, our results indicate that BLV infections are widespread in the dairy farms of China. Vaginal secretions and feces may be involved in BLV transmission. A BLV infection may result in reduced milk yield and increased SCS in a parity and lactation stage-restricted manner. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Methodological aspects of serosurveillance in resource-poor settings.
Sternberg Lewerin, Susanna; Wolff, Cecilia; Masembe, Charles; Ståhl, Karl; Boqvist, Sofia; Franko, Mikael Andersson
2018-01-01
Animal production is important for the agricultural economy in low-income countries, but is threatened by infectious diseases. Serosurveys are conducted for different reasons such as disease detection, risk factor studies, disease monitoring and establishing disease-free status. Most reports on such serosurveys include some discussion about methodological constraints but still, by necessity, rely on serological results for case definition. This study uses a cross-sectional serosurvey for foot-and-mouth disease (FMD), Rift Valley fever (RVF) and contagious bovine pleuropneumonia (CBPP) in cattle in three districts in Western Uganda to illustrate the limitations of this approach, addressing the questions of what flaws can be expected in sampling and diagnostics and how these influence the results. The target was to collect blood samples from 60 cattle herds per district. To reflect the recent infection history of the herd, young animals (two to five years) were prioritised. The farmers were interviewed about management, cattle trade, cattle health and vaccination. Commercial ELISAs were used for serological analyses: for CBPP the IDEXX CBPP Mycoplasma mycoides subspecies mycoides antibody test kit, for RVF the ID Screen Rift Valley Fever competitive ELISA, and for FMD the PrioCHECK FMDV NS. Apparent prevalence, true prevalence and associations with herd characteristics were assessed. The sampling plans could not be entirely fulfilled, nor the number of tests run in the laboratory. There were reactors to all three diseases with an apparent prevalence of approximately 30 per cent for CBPP, 6 per cent for RVF and 7 per cent for FMD. Calculation of true prevalence based on test sensitivity and specificity resulted in a slightly higher prevalence figure for CBPP and lower figures for RVF and FMD. The study illustrates the importance of considering diagnostic test performance when interpreting results from serosurveys, and the challenge of representative sampling and laboratory work in low-income countries.
Sapozhnikova, Yelena; Simons, Tawana; Lehotay, Steven J
2015-05-13
A simple, fast, and cost-effective sample preparation method, previously developed and validated for the analysis of organic contaminants in fish using low-pressure gas chromatography-tandem mass spectrometry (LPGC-MS/MS), was evaluated for the analysis of polybrominated diphenyl ethers (PBDEs) and dichlorodiphenyltrichloroethane (DDT) pesticides using enzyme-linked immunosorbent assay (ELISA). The sample preparation technique was based on the quick, easy, cheap, rugged, effective, and safe (QuEChERS) approach with filter-vial dispersive solid phase extraction (d-SPE). Incurred PBDEs and DDTs were analyzed in three types of fish with 3-10% lipid content: Pacific croaker, salmon, and National Institute of Standards and Technology (NIST) Standard Reference Material 1947 (Lake Michigan fish tissue). LPGC-MS/MS and ELISA results were in agreement: 108-111 and 65-82% accuracy ELISA versus LPGC-MS/MS results for PBDEs and DDTs, respectively. Similar detection limits were achieved for ELISA and LPGC-MS/MS. Matrix effects (MEs) were significant (e.g., -60%) for PBDE measurement in ELISA, but not a factor in the case of DDT pesticides. This study demonstrated that the sample preparation method can be adopted for semiquantitative screening analysis of fish samples by commercial kits for PBDEs and DDTs.
Investigation of enrofloxacin residues in broiler tissues using ELISA and LC-MS/MS.
Panzenhagen, Pedro Henrique N; Aguiar, Waldemir S; Gouvêa, Raquel; de Oliveira, Andréa M G; Barreto, Fabiano; Pereira, Virgínia L A; Aquino, Maria Helena C
2016-01-01
This study investigated the efficiency of an enrofloxacin ELISA test kit to detect the presence of enrofloxacin residues in broiler tissues compared with LC-MS/MS. Broiler tissues from 72 samples consisting of 60 breast muscle, six pools of livers (500 g each) and six pools of kidneys (500 g each) were obtained from six different slaughterhouses. Breast muscle from 10 carcasses and pools of livers and kidneys from approximately 200 carcasses of the same flock were collected from each slaughterhouse. ELISA and HPLC were used to identify and quantify the contamination of the samples with enrofloxacin. A total of 72% of the analysed samples contained enrofloxacin residues detected by the ELISA and 22.2% were detected by LC-MS/MS. The mean values of enrofloxacin contamination found in chicken breast by ELISA and HPLC were 8.63 and 12.25 μg kg(-1), respectively. None of the samples exceeded the maximum limit of 100 μg kg(-1) by both methods set by the European Union as well as the Brazilian Agriculture Ministry. All positive samples for enrofloxacin residues detected by LC-MS/MS were also positive by ELISA. These data confirm the efficiency of the ELISA test, and suggest its use as a screening method for enrofloxacin residues in poultry tissues due to its quick results, low price and ease of applicability.
Comparison of Coxiella burnetii shedding in milk of dairy bovine, caprine, and ovine herds.
Rodolakis, A; Berri, M; Héchard, C; Caudron, C; Souriau, A; Bodier, C C; Blanchard, B; Camuset, P; Devillechaise, P; Natorp, J C; Vadet, J P; Arricau-Bouvery, N
2007-12-01
The shedding of Coxiella burnetii in bovine, caprine, and ovine milk was measured using PCR, in 3 herds for each species, the bulk tank milk samples of which were positive at the time of their selection. Milk samples of 95 cows, 120 goats, and 90 ewes were sampled over 16 wk, as was the bulk tank milk. The shedding of C. burnetii in vaginal mucus and feces was checked at the beginning of the experiment and 2 mo later. The clinical signs in the selected herds as well as the duration and the shedding routes differed among the 3 species. The cows were asymptomatic and shed C. burnetii almost exclusively in milk. In one of the caprine herds, abortions due to C. burnetii were reported. The goats excreted the bacteria mainly in milk. In contrast, the ewes, which came from flocks with abortions due to Q fever (C. burnetii infection), shed the bacteria mostly in feces and in vaginal mucus. This could explain why human outbreaks of Q fever are more often related to ovine flocks than to bovine herds. These excretions did not seem more frequent when the samples were taken close to parturition. The samples were taken from 0 to 421 d after parturition in bovine herds and from 5 to 119 d and 11 to 238 d after parturition in the caprine and ovine herds, respectively. The shedding in milk was sometimes intermittent, and several animals shed the bacteria but were negative by ELISA: 80% of the ewes were seronegative, underscoring the lack of sensitivity of the ELISA tests available for veterinary diagnosis. The detection of antibodies in milk seems more sensitive than it is in serum.
Khatami, Alireza; Seyedin, Zahra; Daneshpazhooh, Maryam
2015-01-01
Background. Serum desmoglein enzyme-linked immunosorbent assay (ELISA) is used for the diagnosis and monitoring of pemphigus diseases. Objectives. To compare the diagnostic accuracy of salivary antidesmoglein (Dsg) 1 and 3 ELISA in the diagnosis of pemphigus vulgaris (PV) patients with that of serum desmogleins ELISA. Methods. Eighty-six untreated PV patients and 180 age- and sex-matched PV-free controls were recruited in this case-control study. PV was diagnosed based on clinical, histopathological, and direct immunofluorescence findings. After processing, serum and salivary anti-Dsg 1 and 3 were measured by the ELISA method using Euroimmun kit (Lübeck, Germany). Results. Using the cut-off point of 20 relative units (RU)/mL, the serum anti-Dsg 1 and 3 ELISA were positive in 62 (72.1%) and 83 (96.5%) patients, respectively, and the salivary anti-Dsg 1 and 3 ELISA were positive in 31 (36.1%) and 63 (73.3%) patients, respectively. The specificity of salivary anti-Dsg 1 and anti-Dsg 3 were both 98.9%. Optimal cut-off values of 7.7 and 13.4 RU/mL were determined for the salivary anti-Dsg 1 and anti-Dsg 3 ELISA, respectively. Conclusion. Salivary anti-Dsg 1 and 3 ELISA with high specificities (98.9%) could be suggested as safe and noninvasive methods for the diagnosis of PV when obtaining a blood sample is difficult. PMID:25688364
Wu, Xin-Lan; Yu, Shu-Juan; Kang, Ke-Ren
2015-03-01
In this study, an indirect competitive enzyme-linked immunoassay (ic-ELISA) based on monoclonal antibody for 4(5)-Methylimidazole (4-MI) detection was described. The artificial antigens were prepared by conjugating bovine serum albumin (BSA) or ovalbumin (OVA) with the hapten of 4-MI. And monoclonal antibody, evaluated by ic-ELISA, was obtained by immunizing BABL/c mice. After optimizing, a standard curve for ic-ELISA detection on 4-MI was obtained with the linear detection range of 0.64-20.48 mg/L. The cross-reactivity (CR) of all the structural analogues of 4-MI was less than 5.62%. The recoveries of 4-MI in caramels detection were ranged from 88.69% to 114.09%, with relative standard deviation (n=3) below 8.07%. The results suggested that the established ic-ELISA is promising for 4-MI commercial detection in caramels. Copyright © 2014 Elsevier Ltd. All rights reserved.
Foddai, Alessandro; Stockmarr, Anders; Boklund, Anette
2016-06-21
The temporal sensitivity of the surveillance system (TemSSe) for Bovine Viral Diarrhea (BVD) in Danish dairy herds was evaluated. Currently, the Danish antibody blocking ELISA is used to test quarterly bulk tank milk (BTM). To optimize the surveillance system as an early warning system, we considered the possibility of using the SVANOVIR ELISA, as this test has been shown to detect BVD-positive herds earlier than the blocking ELISA in BTM tests. Information from data (2010) and outputs from two published stochastic models were fed into a stochastic scenario tree to estimate the TemSSe. For that purpose we considered: the risk of BVD introduction into the dairy population, the ELISA used and the high risk period (HRP) from BVD introduction to testing (at 90 or 365 days). The effect of introducing one persistently infected (PI) calf or one transiently infected (TI) milking cow into 1 (or 8) dairy herd(s) was investigated. Additionally we estimated the confidence in low (PLow) herd prevalence (<8/4109 infected herds) and the confidence in complete freedom (PFree) from BVD (< 1/4109). The TemSSe, the PLow, and the PFree were higher, when tests were performed 365 days after BVD introduction, than after 90 days. Estimates were usually higher for the SVANOVIR than for the blocking ELISA, and when a PI rather than a TI was introduced into the herd(s). For instance, with the current system, the median TemSSe was 64.5 %, 90 days after a PI calf was introduced into eight dairy herds. The related median PLow was 72.5 %. When a PI calf was introduced into one herd the median TemSSe was 12.1 %, while the related PFree was 51.6 %. With the SVANOVIR ELISA these estimates were 99.0 %; 98.9 %, 43.7 % and 62.4 %, respectively. The replacement of the blocking ELISA with the SVANOVIR could increase the TemSSe, the PLow and PFree remarkably. Those results could be used to optimize the Danish BVD surveillance system. Furthermore, the approach proposed in this study, for including the effect of the HRP within the scenario tree methodology, could be applied to optimize early warning surveillance systems of different animal diseases.
Bosnjakovic, Admira; Mishra, Manoj K.; Han, Hye Jung; Romero, Roberto; Kannan, Rangaramanujam M.
2012-01-01
A dendrimer-based sandwich type enzyme-linked immunosorbent assay (ELISA) was developed for the improved detection of recombinant human tumor necrosis factor-alpha (TNF-α) for early diagnosis of perinatal diseases. Hydroxyl-terminated generation four poly(amidoamine) dendrimer (G4-OH) was used for the development of a solid phase bio-sensing platform. The surface of the ELISA plate was modified with polyethylene-glycol (PEG) and thiol-functionalized G4-OH was immobilized on the PEG-functionalized plate. A capture antibody was oxidized and covalently immobilized onto the dendrimer-modified ELISA plate, which provides favorable orientation for the antigen binding sites towards the analyte. The dendrimer-modified plate showed enhanced sensitivity, and the detection limit for TNF-α was found to be 0.48 pg mL−1, which is significantly better than the commercially available ELISA kit. The selectivity of the dendrimer-modified ELISA plate was further evaluated with a mixture of cytokines, which showed results for similar to that of TNF-α alone. The modified plate provides a greater opportunity for the detection of a wide range of cytokines and biomarkers. PMID:22365129
The feasibility of harmonizing gluten ELISA measurements.
Rzychon, Malgorzata; Brohée, Marcel; Cordeiro, Fernando; Haraszi, Reka; Ulberth, Franz; O'Connor, Gavin
2017-11-01
Many publications have highlighted that routine ELISA methods do not give rise to equivalent gluten content measurement results. In this study, we assess this variation between results and its likely impact on the enforcement of the EU gluten-free legislation. This study systematically examines the feasibility of harmonizing gluten ELISA assays by the introduction of: a common extraction procedure; a common calibrator, such as a pure gluten extract and an incurred matrix material. The comparability of measurements is limited by a weak correlation between kit results caused by differences in the selectivity of the methods. This lack of correlation produces bias that cannot be corrected by using reference materials alone. The use of a common calibrator reduced the between-assay variability to some extent, but variation due to differences in selectivity of the assays was unaffected. Consensus on robust markers and their conversion to "gluten content" are required. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.
Kramer, Benedikt; Kneissle, Marcel; Birk, Richard; Rotter, Nicole; Aderhold, Christoph
2018-05-01
Therapeutic options of locally advanced or metastatic head and neck squamous cell carcinoma (HNSCC) are limited. Src and cKIT are key protein regulators for local tumor progression. The aim of the study was to investigate the therapeutic potential of targeted therapies in human squamous cell carcinoma (HNSCC) in vitro. Therefore, the influence of the selective tyrosine kinase inhibitors niotinib, dasatinib, erlotinib, gefitinib and afatinib on Src and cKIT expression in Human papilloma virus (HPV)-positive and HPV-negative squamous cancer cells (SCC) was analyzed in vitro. ELISA was performed to evaluate the expression of Src and cKIT under the influence of nilotinib, dasatinib, erlotinib, gefitinib and afatinib (10 μmol/l) in HPV-negative and HPV-positive SCC (24-96 h of incubation). Gefitinib significantly increased cKIT expression in HPV-positive and HPV-negative cells whereas nilotinib and afatinib decreased cKIT expression in HPV-positive SCC. The influence of tyrosine kinase inhibitors in HPV-negative SCC was marginal. Surprisingly, Src expression was significantly increased by all tested tyrosine kinase inhibitors in HPV-positive SCC. The results revealed beneficial and unexpected information concerning the interaction of selective tyrosine kinase inhibitors and the tumor biology of HNSCC. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.
Cho, Yun Sang; Lee, Sang-Eun; Ko, Young Joon; Cho, Donghee; Lee, Hyang Shim; Hwang, Inyeong; Nam, Hyangmi; Heo, Eunjung; Kim, Jong Man; Jung, Sukchan
2009-01-01
Enzyme-linked immunosorbent assay (ELISA) has been developed as the ancillary diagnosis of bovine tuberculosis at ante-mortem to overcome the disadvantages of intradermal skin test. In this study, the antigenic proteins were purified, applied to bTB ELISA, and identified through proteomic analysis. Culture filtrate protein of Mycobacterium bovis was fractionated by MonoQ column chromatography, and examined the antigenicity by immunoblotting. The antigenic 20 kDa protein was in-gel digested and identified the antigenome by LTQ mass spectrometer and peptide match fingerprinting, which were MPB64, MPB70, MPB83, Fas, Smc, Nrp, RpoC, Transposase, LeuA, and MtbE. The 20 kDa protein exhibited the highest antigenicity to bTB positive cattle in ELISA and would be useful for bTB serological diagnosis.
VPAC1 Targeted 64Cu-TP3805 kit preparation and its evaluation.
Tripathi, Sushil K; Kumar, Pardeep; Trabulsi, Edouard J; Kim, Sung; McCue, Peter A; Intenzo, Charles; Berger, Adam; Gomella, Leonard; Thakur, Mathew L
2017-08-01
Previously, our laboratory has shown that 64 Cu-TP3805 can specifically target VPAC1 receptors and be used for positron emission tomography (PET) imaging of breast (BC) and prostate cancer (PC) in humans. Present work is aimed at the formulation of a freeze-dried diaminedithiol-peptide (N 2 S 2 -TP3805) kit and it's evaluation for the preparation of 64 Cu labeled TP3805. Parameters such as pH, temperature and incubation time were examined that influenced the radiolabeling efficiency and stability of the product. Kits were prepared under different conditions and radiolabeling efficiency of TP3805 kit was evaluated for a range of pH3.5-8.5, after addition of 64 Cu in 30μl, 0.1M HCl. Incubation temperature (37-90°C) and time (30-120min.) were also investigated. Kits were stored at -10°C and their long term stability was determined as a function of their radiolabeling efficiency. Further, stability of 64 Cu-TP3805 complex was evaluated in presence of fetal bovine serum and bovine serum albumin by using SDS polyacrylamide gel electrophoresis. Kits were then used for PET imaging of BC and PC following eIND (101550) and institutional approvals. Specificity of 64 Cu-TP3805 for VPAC1 was examined with digital autoradiography (DAR) of prostate tissues obtained after prostatectomy, benign prostatic hyperplasia (BPH) tissue, and benign and malignant lymph nodes. Results were compared with corresponding tissue histology. Radiolabeling efficiency was ≥95% at final pH ~7.2 when incubated at 50°C for 90min. Kits were stable up to 18months when stored at -10°C, and 64 Cu-TP3805 complex exhibited excellent stability for up to 4h at room temperature. 64 Cu-TP3805 complex did not show any transchelation even after 2h incubation at 37°C in 10% FBS as well as in BSA as determined by SDS PAGE analysis. DAR identified ≥95% of malignant lesions 11 new PC lesions, 20 high grade prostatic intraepithelial neoplasia, 2/2 ejaculatory ducts and 5/5 urethra verumontanum not previously identified The malignant lymph nodes were correctly identified by DAR and for 3/3 BPH patients, and 5/5 cysts, DAR was negative. In human BC (n=19) and PC (n=26) were imaged with 100% sensitivity. Availability of ready to use N 2 S 2 -peptide kits for 64 Cu labeling is convenient and eliminates possible day to day variation during its routine preparation for clinical use. Copyright © 2017 Elsevier Inc. All rights reserved.
Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...
Asambe, A; Sackey, A K B; Tekdek, L B
2018-03-01
This study investigated the prevalence of African swine fever virus (ASFV) and classical swine fever virus (CSFV) antibodies in pigs in Benue State, Nigeria. Serum samples were collected from a total of 460 pigs, including 416 from 74 piggeries and 44 from Makurdi slaughter slab. The samples were analysed using indirect enzyme-linked immunosorbent assay (ELISA) test kit to detect the presence of ASFV antibodies, while competitive ELISA test kit was used to detect antibodies to CSFV. Our findings showed a total ASF prevalence of 13 (2.8%), while prevalences of 7 (1.7%) and 6 (13.6%) were observed in piggeries and in Makurdi slaughter slab, respectively. However, no CSFV antibody sera were detected in this study. Relatively higher ASFV antibody-positive pigs were detected in the slaughter slab than in piggeries. The difference in prevalence of ASF between the two locations was significantly associated (p = 0.017). These findings suggest the presence of ASFV antibody-positive pig in Benue State, Nigeria. Continuous surveillance and monitoring of these diseases among pigs in Nigeria to prevent any fulminating outbreak are recommended.
Kruse, Niels; Mollenhauer, Brit
2015-11-01
The quantification of α-Synuclein in cerebrospinal fluid (CSF) as a biomarker has gained tremendous interest in the last years. Several commercially available immunoassays are emerging. We here describe the full validation of one commercially available ELISA assay for the quantification of α-Synuclein in human CSF (Covance alpha-Synuclein ELISA kit). The study was conducted within the BIOMARKAPD project in the European initiative Joint Program for Neurodegenerative Diseases (JPND). We investigated the effect of several pre-analytical and analytical confounders: i.e. (1) need for centrifugation of freshly drawn CSF, (2) sample stability, (3) delay of freezing, (4) volume of storage aliquots, (5) freeze/thaw cycles, (6) thawing conditions, (7) dilution linearity, (8) parallelism, (9) spike recovery, and (10) precision. None of these confounders influenced the levels of α-Synuclein in CSF significantly. We found a very high intra-assay precision. The inter-assay precision was lower than expected due to different performances of kit lots used. Overall the validated immunoassay is useful for the quantification of α-Synuclein in human CSF. Copyright © 2015 Elsevier B.V. All rights reserved.
Salgado, Miguel; Kruze, Juan; Collins, Michael T
2007-01-01
Fecal culture has been the primary method used to diagnose paratuberculosis in goats. It is laborious, slow, and expensive. Validation of enzyme-linked immunosorbent assays (ELISAs) on milk samples could make paratuberculosis testing more widely available for goat farmers. The aim of this study was to determine the accuracy of serum and milk ELISAs for paratuberculosis, relative to fecal culture, in Chilean dairy goats. Eight dairy goat herds were selected. Feces, blood, and milk samples were collected from all female goats >2 years old. Fecal samples were cultured using Herrold egg yolk medium with mycobactin J and antibiotics. Serum and milk samples were tested using a commercial ELISA kit for Mycobacterium avium subsp. paratuberculosis antibody detection. A total of 383 goats were tested by ELISA and fecal culture. The sensitivity of ELISA on serum and milk relative to fecal culture was 74.3% (95% CI: 59.8-88.8) and 60% (95% CI: 43.8-76.2), respectively. The corresponding values for ELISA specificity based on the percentage of non- M. avium subsp. paratuberculosis-infected goats testing ELISA-negative were 98.6% (95% CI: 96.6-100) and 99.3% (95% CI: 97.9-100) on serum and milk, respectively. Proportions of positive results for serum and fecal samples were significantly different, whereas the proportions of positive results for milk and fecal samples were not significantly different. The milk ELISA had a moderate level of agreement with fecal culture results (Kappa = 0.57). The paratuberculosis ELISA on goat milk samples may be a cost-effective, accurate alternative to fecal culture.
Sharma, Neelesh; Huynh, Do Luong; Kim, Sung Woo; Ghosh, Mrinmoy; Sodhi, Simrinder Singh; Singh, Amit Kumar; Kim, Nam Eun; Lee, Sung Jin; Hussain, Kafil; Oh, Sung Jong; Jeong, Dong Kee
2017-11-28
The antibacterial and anti-inflammatory properties of lactoferricin have been ascribed to its ability to sequester essential iron. The objective of the study was to clone bovine lactoferricin ( LFcinB ) gene into PiggyBac Transposon vector, expression study in the bovine mammary epithelial stem cells (bMESCs) and also to determine the antimicrobial property of recombinant LFcinB against bovine mastitis-causing organisms. The PiggyBac-LFcinB was transfected into bMESCs by electroporation and a three fold of LFcinB secretion was observed in the transfected bMESCs medium by ELISA assay. Furthermore, the assessment of antimicrobial activity against mastitis causing pathogens Staphylococcus aureus and Escherichia coli demonstrated convincing evidence to prove strong antibacterial activity of LFcinB with 14.0±1.0 mm and 18.0±1.5 mm zone of inhibition against both organisms, respectively. The present study provides the convincing evidence to suggest the potential of PiggyBac transposon system to transfer antibacterial peptide into bMESCs or cow mammary gland and also pave the way to use bovine mammary gland as the bioreactors. Simultaneously, it also suggest toward commercial utilization of LFcinB bioreactor system in pharmaceutical industry.
Sharma, Neelesh; Huynh, Do Luong; Kim, Sung Woo; Ghosh, Mrinmoy; Sodhi, Simrinder Singh; Singh, Amit Kumar; Kim, Nam Eun; Lee, Sung Jin; Hussain, Kafil; Oh, Sung Jong; Jeong, Dong Kee
2017-01-01
The antibacterial and anti-inflammatory properties of lactoferricin have been ascribed to its ability to sequester essential iron. The objective of the study was to clone bovine lactoferricin (LFcinB) gene into PiggyBac Transposon vector, expression study in the bovine mammary epithelial stem cells (bMESCs) and also to determine the antimicrobial property of recombinant LFcinB against bovine mastitis-causing organisms. The PiggyBac-LFcinB was transfected into bMESCs by electroporation and a three fold of LFcinB secretion was observed in the transfected bMESCs medium by ELISA assay. Furthermore, the assessment of antimicrobial activity against mastitis causing pathogens Staphylococcus aureus and Escherichia coli demonstrated convincing evidence to prove strong antibacterial activity of LFcinB with 14.0±1.0 mm and 18.0±1.5 mm zone of inhibition against both organisms, respectively. The present study provides the convincing evidence to suggest the potential of PiggyBac transposon system to transfer antibacterial peptide into bMESCs or cow mammary gland and also pave the way to use bovine mammary gland as the bioreactors. Simultaneously, it also suggest toward commercial utilization of LFcinB bioreactor system in pharmaceutical industry. PMID:29262639
Lexhaller, Barbara; Tompos, Christine; Scherf, Katharina Anne
2017-12-15
Monitoring the compliance of gluten-free foods to the regulatory threshold of 20mg/kg of gluten is essential for celiac disease patients. The different enzyme-linked immunosorbent assays (ELISAs) for gluten detection each have specific characteristics, but there are only a few systematic comparisons. This fundamental study compared the specificities and sensitivities of the R5, G12 and Skerritt monoclonal and two polyclonal antibodies to well-defined gluten protein types (GPT) isolated from wheat, rye and barley flours. Quantitation of protein concentrations by reversed-phase high-performance liquid chromatography provided independent reference values. The ELISA responses showed high variability depending on the type of cereal, the GPT and the antibody used. Overall, ω1,2-gliadins and γ-75k-secalins were most reactive, whereas ω5-gliadins and γ-, B- and D-hordeins were detected with the lowest sensitivities. These results revealed which GPT each antibody is most sensitive to and provided novel insights that will be helpful for appropriate calibration of ELISAs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Detection of tetracosactide in plasma by enzyme-linked immunosorbent assay (ELISA).
Martin, Laurent; Chaabo, Ayman; Lasne, Françoise
2015-06-01
As a synthetic analogue of adrenocorticotropic hormone (ACTH), tetracosactide is prohibited in sport by the World Anti-Doping Agency (WADA). An enzyme-linked immunosorbent assay (ELISA) method is proposed for detection of this drug in plasma. Since its structure corresponds to the 24 N-terminal of the 39 amino acids of the natural endogenous peptide ACTH, tetracosactide can be detected with a commercial ELISA kit for ACTH that uses antibodies, the epitopes of which are located in the 1-24 part of ACTH. However, an essential condition for detection specificity is the preliminary total clearance of endogenous ACTH in the plasma samples. This is achieved by a preparative step based on cation-exchange chromatography before ELISA. The method is specific and sensitive (LOD: 30 pg/mL) and may be used as a screening analysis in anti-doping control. The pre-analytical conditions are shown to be of the upmost importance and recommendations for blood collection (EDTA tubes), sample transport (4 °C) and plasma sample storage (-20 °C) are presented. Copyright © 2014 John Wiley & Sons, Ltd.
2013-01-01
Quantitative analysis of protein biomarkers in plasma is typically done by ELISA, but this method is limited by the availability of high-quality antibodies. An alternative approach is protein immunoprecipitation combined with multiple reaction monitoring mass spectrometry (IP-MRM). We compared IP-MRM to ELISA for the analysis of six colon cancer biomarker candidates (metalloproteinase inhibitor 1 (TIMP1), cartilage oligomeric matrix protein (COMP), thrombospondin-2 (THBS2), endoglin (ENG), mesothelin (MSLN) and matrix metalloproteinase-9 (MMP9)) in plasma from colon cancer patients and noncancer controls. Proteins were analyzed by multiplex immunoprecipitation from plasma with the ELISA capture antibodies, further purified by SDS-PAGE, digested and analyzed by stable isotope dilution MRM. IP-MRM provided linear responses (r = 0.978–0.995) between 10 and 640 ng/mL for the target proteins spiked into a “mock plasma” matrix consisting of 60 mg/mL bovine serum albumin. Measurement variation (coefficient of variation at the limit of detection) for IP-MRM assays ranged from 2.3 to 19%, which was similar to variation for ELISAs of the same samples. IP-MRM and ELISA measurements for all target proteins except ENG were highly correlated (r = 0.67–0.97). IP-MRM with high-quality capture antibodies thus provides an effective alternative method to ELISA for protein quantitation in biological fluids. PMID:24224610
Detection of Bovine IgG Isotypes in a PPA-ELISA for Johne's Disease Diagnosis in Infected Herds
Fernández, Bárbara; Gilardoni, Liliana Rosa; Jolly, Ana; Colavecchia, Silvia Beatriz; Paolicchi, Fernando Alberto; Mundo, Silvia Leonor
2012-01-01
Johne's Disease or Paratuberculosis is a chronic granulomatous enteritis disease affecting ruminants. Detection of subclinically infected animals is difficult, hampering the control of this disease. The aim of this work was to evaluate the performance of detection of IgG isotypes in a PPA-ELISA to improve the recognition of cattle naturally infected with Map in different stages. A total of 108 animals from Tuberculosis-free herds were grouped as follows: exposed (n = 30), subclinically infected (n = 26), clinically infected (n = 14), and healthy controls (n = 38). Receiver-operating characteristic (ROC) curves of isotypes/PPA-ELISAs were constructed and areas under the curves were compared to evaluate the performance of each test. Our study demonstrated that the conventional PPA-ELISA (detecting IgG) is the best to identify clinically infected animals with high sensitivity (92.9%) and specificity (100%). Meanwhile, IgG2/PPA-ELISA improved the number of subclinically infected cattle detected as compared with conventional IgG/PPA-ELISA (53.8 versus 23.1%). In addition, it had the maximum sensitivity (65.0%, taking into account all Map-infected cattle). In conclusion, the combination of IgG and IgG2/PPA-ELISAs may improve the identification of Map-infected cattle in different stages of disease. The usefulness of IgG2 detection in serological tests for Johne's Disease diagnosis should be further evaluated. PMID:22792511
Detection of Bovine IgG Isotypes in a PPA-ELISA for Johne's Disease Diagnosis in Infected Herds.
Fernández, Bárbara; Gilardoni, Liliana Rosa; Jolly, Ana; Colavecchia, Silvia Beatriz; Paolicchi, Fernando Alberto; Mundo, Silvia Leonor
2012-01-01
Johne's Disease or Paratuberculosis is a chronic granulomatous enteritis disease affecting ruminants. Detection of subclinically infected animals is difficult, hampering the control of this disease. The aim of this work was to evaluate the performance of detection of IgG isotypes in a PPA-ELISA to improve the recognition of cattle naturally infected with Map in different stages. A total of 108 animals from Tuberculosis-free herds were grouped as follows: exposed (n = 30), subclinically infected (n = 26), clinically infected (n = 14), and healthy controls (n = 38). Receiver-operating characteristic (ROC) curves of isotypes/PPA-ELISAs were constructed and areas under the curves were compared to evaluate the performance of each test. Our study demonstrated that the conventional PPA-ELISA (detecting IgG) is the best to identify clinically infected animals with high sensitivity (92.9%) and specificity (100%). Meanwhile, IgG2/PPA-ELISA improved the number of subclinically infected cattle detected as compared with conventional IgG/PPA-ELISA (53.8 versus 23.1%). In addition, it had the maximum sensitivity (65.0%, taking into account all Map-infected cattle). In conclusion, the combination of IgG and IgG2/PPA-ELISAs may improve the identification of Map-infected cattle in different stages of disease. The usefulness of IgG2 detection in serological tests for Johne's Disease diagnosis should be further evaluated.
Feberwee, A; Mekkes, D R; de Wit, J J; Hartman, E G; Pijpers, A
2005-06-01
In this study, the technical performance of culture, two commercially available polymerase chain reaction (PCR) tests, rapid plate agglutination (RPA) test, hemagglutination inhibition (HI) test, and eight commercially available enzyme-linked immunosorbent assays (ELISAs) were compared for the detection of avian mycoplasma infections from 3 days postinfection (d.p.i.) through 35 d.p.i. The tests were carried out on samples from specified pathogen-free layers that were infected at 66 wk of age with recent Mycoplasma synoviae (MS) and Mycoplasma gallisepticum (MG) field strains, MS and MG ATCC strains, and Mycoplasma imitans (MIM), respectively. Results showed a high percentage of positive samples in the homologous infected groups and a high percentage of negative samples (100%) in the uninfected and heterologous infected groups during 35 d.p.i. of both culture and PCR tests. For the group infected with the MG 15302 ATCC strain, serology was more sensitive than bacteriology. All MG and MS tests, with the exception of MG ELISA kit D showed a lower percentage of positive samples during 35 d.p.i. for the detection of the MG and MS ATCC strain infection compared with that of the field strains. Also, the number of cross-reactions (false positives) in the serologic tests was lower after infection with an ATCC strain than after an infection with the MG or MS field strain. Contradictory to other studies, the ELISAs and the RPA test using undiluted serum showed a relatively high number of false-positive results. The MG ELISAs (except ELISA kit D) showed more false-positive results (up to 37%) in the MIM-infected group than in the MS-infected groups. This was not unexpected, as MIM and MG have a close antigenic relationship. The results of the serologic tests in this study showed that a certain level of false-positive results can be expected in about any serologic test. Although the level of false-positive results varied between several serologic tests, this study showed that it is not advisable to rely completely on one test (system) only.
Tian, Zhancheng; Du, Xiaoyue; Du, Junzheng; Gao, Shandian; Yu, Ruiming; Hassan, Muhammad Adeel; Liu, Guangyuan; Luo, Jianxun; Yin, Hong
2018-06-01
Tropical theileriosis, caused by Theileria annulata, is distributed worldwide and causes great economic losses in dairy. The reliable diagnostic method is critical for prevention and control of the disease. In this study, a sporozoite and macroschizont gene 2 (spm2) protein from T. annulata was used to develop an indirect ELISA for tropical theileriosis. Specificity test showed that there were no cross-reactions with antibodies raised against other bovine piroplasm species using ELISA or western blotting. The specificity and sensitivity were 98.4% and 98.7%, respectively, with a threshold of 35.5% of the specific mean antibody rate (AbR). Furthermore, a total of 196 field sera samples collected from Xinjiang and Gansu provinces were detected by the spm2 ELISA and IFA. The results obtained with the spm2 ELISA and IFA in this study had the moderate agreement. The average positive rates of T. annulata sera samples detected in the present study were close to the prevalence of previous reports in these endemic areas. This indicated that the Spm2 ELISA could be used as a reliable diagnostic tool for serological survey of T. annulata infection in areas where Theileria parva is not present. Copyright © 2018 Elsevier B.V. All rights reserved.
Khuda, Sefat E; Sharma, Girdhari M; Gaines, Dennis; Do, Andrew B; Pereira, Marion; Chang, Michael; Ferguson, Martine; Williams, Kristina M
2016-08-01
A comprehensive study was designed to determine the frequency and levels of soy allergen in packaged bakery and snack food products. A representative sample of products with no soy allergen disclosed on the label was analysed using two widely used enzyme-linked immunosorbent assay (ELISA) methods. Samples were chosen that either had no soy identified on the product label or which had a soy precautionary statement. Among 558 bakery and snack products, soy protein was detected in 17% of the products using the Neogen (NE) kit and 11% of the products using the Elisa Systems (ES) kit. The disagreement rates between kits were 8.8% for bakery products and 3.3% for snack products. Overall soy protein was detected at higher frequency in bakery products than in snack foods. Among 284 bakery samples, soy protein was detected in 25% of the samples with no precautionary statement and 19% of the samples which had a precautionary statement. Among 274 snack samples, soy protein was detected in 11% of the samples with no precautionary statement and 9% of the samples which had a precautionary statement. The sample repeatability was at an acceptable level (< 9%) for each method and food commodity. The reproducibility between kits was 23% for bakery foods and 36% for snack foods. None of the bakery (21) and snack (6) products without precautionary labelling (measured level > 5 ppm) had a higher level of soy protein per serving compared with the eliciting dose10 (ED10) of 10.6 mg for soy allergic patients. But the level of soy protein per serving may be clinically relevant to a subpopulation of soy allergic patients if a more stringent eliciting dose is applied. These findings emphasise that suitable detection methodologies and references doses are crucial for labelling accuracy and the safety of soy allergic consumers.
Sakaguchi, M; Hori, H; Hattori, S; Irie, S; Imai, A; Yanagida, M; Miyazawa, H; Toda, M; Inouye, S
1999-09-01
Anaphylactic reactions to measles, mumps, and rubella vaccines, including gelatin as a stabilizer, have been reported. It had been found that most of these reactions to live vaccines are caused by the bovine gelatin included in these vaccines. Gelatin mainly includes denatured type I collagen, which consists of alpha1 and alpha2 chains. The current study was designed to investigate the IgE reactivity to alpha1 and alpha2 chains of bovine type I collagen in gelatin-sensitive children. Serum samples were taken from 10 children who had anaphylaxis to the vaccines and high levels of specific IgE to bovine gelatin. Bovine type I collagen was isolated from bovine skin and then separated to alpha1 and alpha2 chains by column chromatography. IgE reactivity to denatured type I collagen and its alpha1 and alpha2 chains was analyzed by immunoblotting, ELISA, and histamine release from the mast cells passive sensitized with IgE antibodies in pooled serum of the children. All children had specific IgE to bovine type I collagen. Furthermore, IgE antibodies in their sera reacted with the alpha;2 chain but not with the alpha1 chain. Similarly, the mast cells sensitized with pooled sera in the children showed alpha2 chain-specific histamine release but not alpha1 chain-specific histamine release. In gelatin allergy denatured bovine type I collagen is a major allergen and IgE-binding sites exist in the alpha2 chain of type I collagen.
Liu, Changqi; Chhabra, Guneet S; Zhao, Jing; Zaffran, Valerie D; Gupta, Sahil; Roux, Kenneth H; Gradziel, Thomas M; Sathe, Shridhar K
2017-10-01
A commercially available monoclonal antibody (mAb)-based direct sandwich enzyme-linked immunosorbent assay (ELISA) kit (BioFront Technologies, Tallahassee, Fla., U.S.A.) was compared with an in-house developed mAb 4C10-based ELISA for almond detection. The assays were comparable in sensitivity (limit of detection < 1 ppm full fat almond, limit of quantification < 5 ppm full fat almond), specificity (no cross-reactivity with 156 tested foods at a concentration of 100000 ppm whole sample), and reproducibility (intra- and interassay variability < 15% CV). The target antigens were stable and detectable in whole almond seeds subjected to autoclaving, blanching, frying, microwaving, and dry roasting. The almond recovery ranges for spiked food matrices were 84.3% to 124.6% for 4C10 ELISA and 81.2% to 127.4% for MonoTrace ELISA. The almond recovery ranges for commercial and laboratory prepared foods with declared/known almond amount were 30.9% to 161.2% for 4C10 ELISA and 38.1% to 207.6% for MonoTrace ELISA. Neither assay registered any false-positive or negative results among the tested commercial and laboratory prepared samples. Ability to detect and quantify trace amounts of almonds is important for improving safety of almond sensitive consumers. Two monoclonal antibody-based ELISAs were compared for almond detection. The information is useful to food industry, regulatory agencies, scientific community, and almond consumers. © 2017 Institute of Food Technologists®.
Galvin, Pamela; Gildea, Sarah; Arkins, Sean; Walsh, Cathal; Cullinane, Ann
2013-12-01
Antibodies against equine influenza virus (EIV) are traditionally quantified by haemagglutination inhibition (HI) or single radial haemolysis (SRH). To evaluate an ELISA for the detection of antibodies against influenza nucleoprotein in the diagnosis and surveillance of equine influenza (EI). The ELISA was compared with the SRH and HI tests. Serial serum samples from 203 naturally and 14 experimentally infected horses, from 60 weanlings following primary vaccination with five different vaccines (two whole inactivated vaccines, two ISCOM-based subunit vaccines and a recombinant canarypox virus vaccine) and from 44 adult horses following annual booster vaccination with six different vaccines were analysed. Fewer seroconversions were detected in clinical samples by ELISA than by SRH or HI but ELISA was more sensitive than SRH in naïve foals post-experimental infection. The ELISA did not detect the antibody response to vaccination with the recombinant canarypox virus vaccine confirming the usefulness of the combination of this kit and vaccine to differentiate between naturally infected and vaccinated horses, that is, DIVA. No DIVA capacity was evident with the other vaccines. The results suggest that this ELISA is a useful supplementary test for the diagnosis of EI although less sensitive than HI or SRH. It is an appropriate test for EI surveillance in a naïve population and may be combined with the recombinant canarypox virus vaccine but not with other commercially available subunit vaccines, in a DIVA strategy. © 2013 Blackwell Publishing Ltd.
Nimata, Masaomi; Okada, Hideki; Kurihara, Kei; Sugimoto, Tsukasa; Honjoh, Tsutomu; Kuroda, Kazuhiko; Yano, Takeo; Tachibana, Hirofumi; Shoji, Masahiro
2018-01-01
Food allergy is a serious health issue worldwide. Implementing allergen labeling regulations is extremely challenging for regulators, food manufacturers, and analytical kit manufacturers. Here we have developed an "amino acid sequence immunoassay" approach to ELISA. The new ELISA comprises of a monoclonal antibody generated via an analyte specific peptide antigen and sodium lauryl sulfate/sulfite solution. This combination enables the antibody to access the epitope site in unfolded analyte protein. The newly developed ELISA recovered 87.1%-106.4% ovalbumin from ovalbumin-incurred model processed foods, thereby demonstrating its applicability as practical egg allergen determination. Furthermore, the comparison of LC-MS/MS and the new ELISA, which targets the amino acid sequence conforming to the LC-MS/MS detection peptide, showed a good agreement. Consequently the harmonization of two methods was demonstrated. The complementary use of the new ELISA and LC-MS analysis can offer a wide range of practical benefits in terms of easiness, cost, accuracy, and efficiency in food allergen analysis. In addition, the new assay is attractive in respect to its easy antigen preparation and predetermined specificity. Graphical abstract The ELISA composing of the monoclonal antibody targeting the amino acid sequence conformed to LC-MS detection peptide, and the protein conformation unfolding reagent was developed. In ovalbumin determination, the developed ELISA showed a good agreement with LC-MS analysis. Consequently the harmonization of immunoassay with LC-MS analysis by using common target amino acid sequence was demonstrated.
Watanabe, Eiki; Kobara, Yuso; Miyake, Shiro
2013-06-01
With the aim of expanding the applicability of a kit-based enzyme-linked immunosorbent assay (ELISA) for the neonicotinoid insecticide thiamethoxam, the ELISA was newly applied to three kinds of agricultural samples (green pepper, eggplant and spinach). To offer the ELISA as a screening analysis for thiamethoxam residues, a rapid and simple method of extraction by hand-shaking was used, and speed-up and simplification of the sample treatment before the ELISA analysis were examined. Finally, the validity of the ELISA combined with the proposed extraction method was verified against a reference high-performance liquid chromatography (HPLC) method using real-world agricultural samples. There were no marked matrix effects derived from green pepper and eggplant extracts. On the other hand, although the effect due to a pigment in spinach extract on the assay performance was significant, it was effectively avoided by increasing the dilution level of the spinach extract. For thiamethoxam-spiked samples, acceptable recoveries of 97.9-109.1% and coefficients of variation of 0.3-11.5% were obtained. Inspection of the validity of the ELISA by comparison with the reference HPLC method showed that the two analytical results were very similar, and a high correlation was found between them (r>0.997). The evaluated ELISA combined with hand-shaking extraction provided a rapid and simple screening analysis that was quantitative and reliable for the detection of thiamethoxam in complex agricultural products. © 2012 Society of Chemical Industry.
Monoclonal IgA Antibodies for Aflatoxin Immunoassays
Ertekin, Özlem; Pirinçci, Şerife Şeyda; Öztürk, Selma
2016-01-01
Antibody based techniques are widely used for the detection of aflatoxins which are potent toxins with a high rate of occurrence in many crops. We developed a murine monoclonal antibody of immunoglobulin A (IgA) isotype with a strong binding affinity to aflatoxin B1 (AFB1), aflatoxin B2 (AFB2), aflatoxin G1 (AFG1), aflatoxin G2 (AFG2) and aflatoxin M1 (AFM1). The antibody was effectively used in immunoaffinity column (IAC) and ELISA kit development. The performance of the IACs was compatible with AOAC performance standards for affinity columns (Test Method: AOAC 991.31). The total binding capacity of the IACs containing our antibody was 111 ng, 70 ng, 114 ng and 73 ng for AFB1, AFB2, and AFG1 andAFG2, respectively. Furthermore, the recovery rates of 5 ng of each AF derivative loaded to the IACs were determined as 104.9%, 82.4%, 85.5% and 70.7% for AFB1, AFB2, AFG1 and AFG2, respectively. As for the ELISA kit developed using non-oriented, purified IgA antibody, we observed a detection range of 2–50 µg/L with 40 min total test time. The monoclonal antibody developed in this research is hitherto the first presentation of quadruple antigen binding IgA monoclonal antibodies in mycotoxin analysis and also the first study of their utilization in ELISA and IACs. IgA antibodies are valuable alternatives for immunoassay development, in terms of both sensitivity and ease of preparation, since they do not require any orientation effort. PMID:27187470
Fabricating a UV-Vis and Raman Spectroscopy Immunoassay Platform.
Hanson, Cynthia; Israelsen, Nathan D; Sieverts, Michael; Vargis, Elizabeth
2016-11-10
Immunoassays are used to detect proteins based on the presence of associated antibodies. Because of their extensive use in research and clinical settings, a large infrastructure of immunoassay instruments and materials can be found. For example, 96- and 384-well polystyrene plates are available commercially and have a standard design to accommodate ultraviolet-visible (UV-Vis) spectroscopy machines from various manufacturers. In addition, a wide variety of immunoglobulins, detection tags, and blocking agents for customized immunoassay designs such as enzyme-linked immunosorbent assays (ELISA) are available. Despite the existing infrastructure, standard ELISA kits do not meet all research needs, requiring individualized immunoassay development, which can be expensive and time-consuming. For example, ELISA kits have low multiplexing (detection of more than one analyte at a time) capabilities as they usually depend on fluorescence or colorimetric methods for detection. Colorimetric and fluorescent-based analyses have limited multiplexing capabilities due to broad spectral peaks. In contrast, Raman spectroscopy-based methods have a much greater capability for multiplexing due to narrow emission peaks. Another advantage of Raman spectroscopy is that Raman reporters experience significantly less photobleaching than fluorescent tags 1 . Despite the advantages that Raman reporters have over fluorescent and colorimetric tags, protocols to fabricate Raman-based immunoassays are limited. The purpose of this paper is to provide a protocol to prepare functionalized probes to use in conjunction with polystyrene plates for direct detection of analytes by UV-Vis analysis and Raman spectroscopy. This protocol will allow researchers to take a do-it-yourself approach for future multi-analyte detection while capitalizing on pre-established infrastructure.
Conversion of a Capture ELISA to a Luminex xMAP Assay using a Multiplex Antibody Screening Method
Baker, Harold N.; Murphy, Robin; Lopez, Erica; Garcia, Carlos
2012-01-01
The enzyme-linked immunosorbent assay (ELISA) has long been the primary tool for detection of analytes of interest in biological samples for both life science research and clinical diagnostics. However, ELISA has limitations. It is typically performed in a 96-well microplate, and the wells are coated with capture antibody, requiring a relatively large amount of sample to capture an antigen of interest . The large surface area of the wells and the hydrophobic binding of capture antibody can also lead to non-specific binding and increased background. Additionally, most ELISAs rely upon enzyme-mediated amplification of signal in order to achieve reasonable sensitivity. Such amplification is not always linear and can thus skew results. In the past 15 years, a new technology has emerged that offers the benefits of the ELISA, but also enables higher throughput, increased flexibility, reduced sample volume, and lower cost, with a similar workflow 1, 2. Luminex xMAP Technology is a microsphere (bead) array platform enabling both monoplex and multiplex assays that can be applied to both protein and nucleic acid applications 3-5. The beads have the capture antibody covalently immobilized on a smaller surface area, requiring less capture antibody and smaller sample volumes, compared to ELISA, and non-specific binding is significantly reduced. Smaller sample volumes are important when working with limiting samples such as cerebrospinal fluid, synovial fluid, etc. 6. Multiplexing the assay further reduces sample volume requirements, enabling multiple results from a single sample. Recent improvements by Luminex include: the new MAGPIX system, a smaller, less expensive, easier-to-use analyzer; Low-Concentration Magnetic MagPlex Microspheres which eliminate the need for expensive filter plates and come in a working concentration better suited for assay development and low-throughput applications; and the xMAP Antibody Coupling (AbC) Kit, which includes a protocol, reagents, and consumables necessary for coupling beads to the capture antibody of interest. (See Materials section for a detailed list of kit contents.) In this experiment, we convert a pre-optimized ELISA assay for TNF-alpha cytokine to the xMAP platform and compare the performance of the two methods 7-11. TNF-alpha is a biomarker used in the measurement of inflammatory responses in patients with autoimmune disorders. We begin by coupling four candidate capture antibodies to four different microsphere sets or regions. When mixed together, these four sets allow for the simultaneous testing of all four candidates with four separate detection antibodies to determine the best antibody pair, saving reagents, sample and time. Two xMAP assays are then constructed with the two most optimal antibody pairs and their performance is compared to that of the original ELISA assay in regards to signal strength, dynamic range, and sensitivity. PMID:22806215
Giangaspero, Massimo; Savini, Giovanni; Orusa, Riccardo; Osawa, Takeshi; Harasawa, Ryô
2013-01-01
Ovine sera collected in the Prefectures of Hokkaido, Aomori and Iwate in the Northern Japan were examined for the presence of antibodies against Respiratory syncytial virus (RSV), bovine Herpesvirus type 1 (infectious bovine rhinotracheitis: IBR) and Parainfluenza virus type 3 (PIV3) using serum neutralisation (SN) and enzyme-linked immunosorbent assay (ELISA) tests. Twenty-three animals (11.73%) out of the 196 tested were sero-positive to PIV3. Sixteen animals (8.69%) out of the 184 tested reacted to RSV. No animals were positive to IBR antigen. Sero-conversions to PIV3 were detected in Hokkaido and Iwate (14.92% and 8.82%, respectively). Antibodies against RSV were detected in Hokkaido (9.23%) and Aomori (14.28%). Although no diagnostic measures were in place, the infections did not appear to be related to any reduction in sheep productivity.
Armengol, Ramon; Villalba, Daniel; Coma, Ester; Porquet, Lourdes; Jubert, Anna
2017-01-01
Bovine herpesvirus type 1 (BoHV-1) is the causative agent for infectious bovine rhinotracheitis and infectious pustular vulvovaginitis in cows or balanoposthitis in bulls. In this study, individual and bulk tank milk (BTM) samples from 5 Catalan dairy farms with different control strategies against BoHV-1 were analysed during the course of a year for milk quality parameters and glycoprotein E (gE) antibodies. Detection of gE antibodies was carried out with ELISA techniques. Prevalence of BoHV-1 varied between farms, and was stable during the study in individual and BTM samples. Comparing the antibody results of samples with milk quality parameters, positive samples with higher levels of antibodies corresponded to lower lactose and to higher percentages of fat and somatic cells. PMID:28761669
Pritchard, G C; Banks, M; Vernon, R E
2003-07-26
Infectious bovine rhinotracheitis (IBR) virus infection was detected by an antibody ELISA in the bulk milk of a large closed dairy herd of high health status in an area of low cattle density in East Anglia. The herd was managed under high standards of biosecurity and was known to have been serologically free of IBR virus for the previous 13 years. Although over 70 per cent of the cows had seroconverted to IBR virus no clinical signs were observed apart from a slight bilateral watery ocular discharge in a few cows, and their performance and productivity were unaffected. The causal virus, which was isolated after it had been reactivated with corticosteroid, had the DNA profile of a bovine herpesvirus type 1 strain normally associated with clinically severe respiratory disease. In spite of extensive enquiries and seroepidemiological investigations the source of the infection was not determined.
Prince, Harry E; Altrich, Michelle L; Nowicki, Marek J
2016-10-01
The identification of nearly 3,500 cases of chikungunya virus (CHIKV) infection in U.S. residents returning in 2014 and 2015 from areas in which it is endemic has raised concerns within the transplant community that, should recently infected individuals become organ and/or tissue donors, CHIKV would be transmitted to transplant recipients. Thus, tests designed to detect recent CHIKV infection among U.S. organ and tissue donors may become necessary in the future. Accordingly, we evaluated 2 enzyme-linked immunosorbent assays (ELISAs) for CHIKV IgM readily available in the United States using 1,000 deidentified serum or plasma specimens collected from donors between November 2014 and March 2015. The Euroimmun indirect ELISA identified 38 reactive specimens; however, all 38 were negative for CHIKV IgG and IgM in immunofluorescence assays (IFAs) conducted at a reference laboratory and, thus, were falsely reactive in the Euroimmun CHIKV IgM assay. The InBios IgM-capture ELISA identified 26 reactive samples, and one was still reactive (index ≥ 1.00) when retested using the InBios kit with a background subtraction modification to identify false reactivity. This reactive specimen was CHIKV IgM negative but IgG positive by IFAs at two reference laboratories; plaque reduction neutralization testing (PRNT) demonstrated CHIKV-specific reactivity. The IgG and PRNT findings strongly suggest that the InBios CHIKV IgM-reactive result represents true reactivity, even though the IgM IFA result was negative. If testing organ/tissue donors for CHIKV IgM becomes necessary, the limitations of the currently available CHIKV IgM ELISAs and options for their optimization must be understood to avoid organ/tissue wastage due to falsely reactive results. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Hunsperger, Elizabeth A.; Yoksan, Sutee; Buchy, Philippe; Nguyen, Vinh Chau; Sekaran, Shamala Devi; Enria, Delia A.; Vazquez, Susana; Cartozian, Elizabeth; Pelegrino, Jose L.; Artsob, Harvey; Guzman, Maria G.; Olliaro, Piero; Zwang, Julien; Guillerm, Martine; Kliks, Susie; Halstead, Scott; Peeling, Rosanna W.; Margolis, Harold S.
2014-01-01
Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60–75% and specificity 71–80%; NS1 RDT sensitivity was 38–71% and specificity 76–80%; the IgM anti-DENV RDTs sensitivity was 30–96%, with a specificity of 86–92%, and IgM anti-DENV ELISA sensitivity was 96–98% and specificity 78–91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88–94%. PMID:25330157
Lai, Chung-Hsu; Chang, Lin-Li; Lin, Jiun-Nong; Chen, Wei-Fang; Kuo, Li-Li; Lin, Hsi-Hsun; Chen, Yen-Hsu
2013-01-01
Q fever is serologically cross-reactive with other intracellular microorganisms. However, studies of the serological status of Mycoplasma pneumoniae and Chlamydophila pneumoniae during Q fever are rare. We conducted a retrospective serological study of M. pneumoniae and C. pneumoniae by enzyme-linked immunosorbent assay (ELISA), a method widely used in clinical practice, in 102 cases of acute Q fever, 39 cases of scrub typhus, and 14 cases of murine typhus. The seropositive (57.8%, 7.7%, and 0%, p<0.001) and seroconversion rates (50.6%, 8.8%, and 0%, p<0.001) of M. pneumoniae IgM, but not M. pneumoniae IgG and C. pneumoniae IgG/IgM, in acute Q fever were significantly higher than in scrub typhus and murine typhus. Another ELISA kit also revealed a high seropositivity (49.5%) and seroconversion rate (33.3%) of M. pneumoniae IgM in acute Q fever. The temporal and age distributions of patients with positive M. pneumoniae IgM were not typical of M. pneumoniae pneumonia. Comparing acute Q fever patients who were positive for M. pneumoniae IgM (59 cases) with those who were negative (43 cases), the demographic characteristics and underlying diseases were not different. In addition, the clinical manifestations associated with atypical pneumonia, including headache (71.2% vs. 81.4%, p=0.255), sore throat (8.5% vs. 16.3%, p=0.351), cough (35.6% vs. 23.3%, p=0.199), and chest x-ray suggesting pneumonia (19.3% vs. 9.5%, p=0.258), were unchanged between the two groups. Clinicians should be aware of the high seroprevalence of M. pneumoniae IgM in acute Q fever, particularly with ELISA kits, which can lead to misdiagnosis, overestimations of the prevalence of M. pneumoniae pneumonia, and underestimations of the true prevalence of Q fever pneumonia.
Lai, Chung-Hsu; Chang, Lin-Li; Lin, Jiun-Nong; Chen, Wei-Fang; Kuo, Li-Li; Lin, Hsi-Hsun; Chen, Yen-Hsu
2013-01-01
Q fever is serologically cross-reactive with other intracellular microorganisms. However, studies of the serological status of Mycoplasma pneumoniae and Chlamydophila pneumoniae during Q fever are rare. We conducted a retrospective serological study of M. pneumoniae and C. pneumoniae by enzyme-linked immunosorbent assay (ELISA), a method widely used in clinical practice, in 102 cases of acute Q fever, 39 cases of scrub typhus, and 14 cases of murine typhus. The seropositive (57.8%, 7.7%, and 0%, p<0.001) and seroconversion rates (50.6%, 8.8%, and 0%, p<0.001) of M. pneumoniae IgM, but not M. pneumoniae IgG and C. pneumoniae IgG/IgM, in acute Q fever were significantly higher than in scrub typhus and murine typhus. Another ELISA kit also revealed a high seropositivity (49.5%) and seroconversion rate (33.3%) of M. pneumoniae IgM in acute Q fever. The temporal and age distributions of patients with positive M. pneumoniae IgM were not typical of M. pneumoniae pneumonia. Comparing acute Q fever patients who were positive for M. pneumoniae IgM (59 cases) with those who were negative (43 cases), the demographic characteristics and underlying diseases were not different. In addition, the clinical manifestations associated with atypical pneumonia, including headache (71.2% vs. 81.4%, p=0.255), sore throat (8.5% vs. 16.3%, p=0.351), cough (35.6% vs. 23.3%, p=0.199), and chest x-ray suggesting pneumonia (19.3% vs. 9.5%, p=0.258), were unchanged between the two groups. Clinicians should be aware of the high seroprevalence of M. pneumoniae IgM in acute Q fever, particularly with ELISA kits, which can lead to misdiagnosis, overestimations of the prevalence of M. pneumoniae pneumonia, and underestimations of the true prevalence of Q fever pneumonia. PMID:24147043
Joseph Fischer; Brian Strom; Sheri Smith
2009-01-01
The erythrina gall wasp (EGW), Quadrastichus erythrinae Kim 2004, was first detected in Hawaii in 2005 and has been infesting and killing Erythrina trees throughout the island chain since. It is believed EGW originated from Africa (Messing et al. 2009). Its host range appears to be limited to Erythrina; its...
Ellis, T M; Gregory, A R; Logue, G D
1991-06-01
Investigations were conducted into an enterotoxaemia caused by Clostridium spiroforme responsible for significant losses in commercial rabbit farms in Western Australia. Two trials using laboratory and farm bred rabbits were performed to evaluate the protective value of a toxoid prepared from the supernatant of C. spiroforme cultures against intraperitoneal challenge with the trypsin-activated toxin of C. spiroforme. The trials showed clearly that a single vaccination at weaning (four weeks) was protective against toxin but more complete and lasting protection was conferred following a second vaccination administered 14 days after the first. Adults likewise showed similar levels of protective antibodies but did not appear to pass on this protection to their kits although ELISA results indicated levels of antibody in kits from unvaccinated mother to be lower than progeny from vaccinated mothers. However antibody levels in kits from vaccinated mothers were very low and did not protect against challenge with toxin.
Westman, Mark E; Malik, Richard; Hall, Evelyn; Sheehy, Paul A; Norris, Jacqueline M
2015-10-01
This study challenges the commonly held view that the feline immunodeficiency virus (FIV) infection status of FIV-vaccinated cats cannot be determined using point-of-care antibody test kits due to indistinguishable antibody production in FIV-vaccinated and naturally FIV-infected cats. The performance of three commercially available point-of-care antibody test kits was compared in a mixed population of FIV-vaccinated (n=119) and FIV-unvaccinated (n=239) cats in Australia. FIV infection status was assigned by considering the results of all antibody kits in concert with results from a commercially available PCR assay (FIV RealPCR™). Two lateral flow immunochromatography test kits (Witness FeLV/FIV; Anigen Rapid FIV/FeLV) had excellent overall sensitivity (100%; 100%) and specificity (98%; 100%) and could discern the true FIV infection status of cats, irrespective of FIV vaccination history. The lateral flow ELISA test kit (SNAP FIV/FeLV Combo) could not determine if antibodies detected were due to previous FIV vaccination, natural FIV infection, or both. The sensitivity and specificity of FIV RealPCR™ for detection of viral and proviral nucleic acid was 92% and 99%, respectively. These results will potentially change the way veterinary practitioners screen for FIV in jurisdictions where FIV vaccination is practiced, especially in shelter scenarios where the feasibility of mass screening is impacted by the cost of testing. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Plut, Jan; Toplak, Ivan; Štukelj, Marina
2018-06-01
Over the last few years several porcine epidemic diarrhoea (PED) outbreaks have been discovered in Europe including the first PED case in Slovenia in January 2015. The aim of this study was to determine when PED virus (PEDV) infection started in Slovenia. Serum samples collected between 2012 and 2016 were tested. Three hundred and seventy-five serum samples were collected from 132 Slovenian small, one-site pig farms. Samples were tested for PEDV antibodies utilising three different serological methods: commercially-available indirect ELISA, in-house blocking ELISA test and Immunoperoxidase Monolayer Assay (IPMA) test. One hundred and seventy (45.33%) tested samples were found positive by the commercially-available ELISA test kit, and 10 (5.68%) of these 170 samples found positive were positive by the in-house blocking ELISA. Only these 10 samples were collected from a farm where clinical signs of PED infection had been observed and PEDV was confirmed by RT-PCR methodology; the other 160 samples were collected randomly. Thirty-two samples with the highest S/P value obtained with the commercial ELISA were all negative with IPMA. Reasons for the high variance in the results obtained remain unclear; more research is required to ensure higher sensitivity and specificity in terms of PEDV antibody tests and other PED diagnostic methods.
Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.
Sparding, Nadja; Slotved, Hans-Christian; Nicolaisen, Gert M; Giese, Steen B; Elmlund, Jón; Steenhard, Nina R
2014-01-01
After a potential biological incident the sampling strategy and sample analysis are crucial for the outcome of the investigation and identification. In this study, we have developed a simple sandwich ELISA based on commercial components to quantify BSA (used as a surrogate for ricin) with a detection range of 1.32-80 ng/mL. We used the ELISA to evaluate different protein swabbing procedures (swabbing techniques and after-swabbing treatments) for two swab types: a cotton gauze swab and a flocked nylon swab. The optimal swabbing procedure for each swab type was used to obtain recovery efficiencies from different surface materials. The surface recoveries using the optimal swabbing procedure ranged from 0-60% and were significantly higher from nonporous surfaces compared to porous surfaces. In conclusion, this study presents a swabbing procedure evaluation and a simple BSA ELISA based on commercial components, which are easy to perform in a laboratory with basic facilities. The data indicate that different swabbing procedures were optimal for each of the tested swab types, and the particular swab preference depends on the surface material to be swabbed.
Development of a lion-specific interferon-gamma assay.
Maas, M; van Kooten, P J S; Schreuder, J; Morar, D; Tijhaar, E; Michel, A L; Rutten, V P M G
2012-10-15
The ongoing spread of bovine tuberculosis (BTB) in African free-ranging lion populations, for example in the Kruger National Park, raises the need for diagnostic assays for BTB in lions. These, in addition, would be highly relevant for zoological gardens worldwide that want to determine the BTB status of their lions, e.g. for translocations. The present study concerns the development of a lion-specific IFN-γ assay, following the production and characterization of monoclonal antibodies specific for lion interferon-gamma (IFN-γ). Recombinant lion IFN-γ (rLIFN-γ) was produced in mammalian cells and used to immunize mice to establish hybridoma cell lines producing monoclonal antibodies. These were used to develop a sensitive, lion IFN-γ-specific capture ELISA, able to detect rLIFN-γ to the level of 160 pg/ml. Recognition of native lion IFN-γ was shown in an initial assessment of supernatants of mitogen stimulated whole blood cultures of 11 known BTB-negative lions. In conclusion, the capture ELISA shows potential as a diagnostic assay for bovine tuberculosis in lions. Preliminary results also indicate the possible use of the test for other (feline) species. Copyright © 2012 Elsevier B.V. All rights reserved.
Evaluation of ELISA screening test for detecting aflatoxin in biogenic dust samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Durant, J.T.
Aflatoxin is a carcinogenic chemical that is sometimes produced when agricultural commodities are infested by the fungi Aspergillus flavus and A. Parasiticus. Aflatoxin has been found to be present in air samples taken around persons handling materials likely to be contaminated. The purpose of this investigation was to demonstrate the feasibility of using an Enzyme Linked Immunosorbent Assay (ELISA) test kit that was developed to screen for aflatoxin in bulk agricultural commodities, to an air sample. Samples were taken from two environments likely to be contaminated with aflatoxin, a dairy farm feed mixing operation and a peanut bagging operation. Themore » dust collected from these environments was considered to be biogenic, in that it originated primarily from biological materials.« less
Trucksess, Mary W; Brewer, Vickery A; Williams, Kristina M; Westphal, Carmen D; Heeres, James T
2004-01-01
Peanuts are one of the 8 most common allergenic foods and a large proportion of peanut-allergic individuals have severe reactions, some to minimal exposure. Specific protein constituents in the peanuts are the cause of the allergic reactions in sensitized individuals who ingest the peanuts. To avoid accidental ingestion of peanut-contaminated food, methods of analysis for the determination of the allergenic proteins in foods are important tools. Such methods could help identify foods inadvertently contaminated with peanuts, thereby reducing the incidence of allergic reactions to peanuts. Commercial immunoassay kits are available but need study for method performance, which requires reference materials for within- and between-laboratory validations. In this study, National Institute of Standards and Technology Standard Reference Material 2387 peanut butter was used. A polytron homogenizer was used to prepare a homogenous aqueous Peanut Butter suspension for the evaluation of method performance of some commercially available immunoassay kits such as Veratox for Peanut Allergen Test (Neogen Corp.), Ridascreen Peanut (R-Biopharm GmbH), and Bio-Kit Peanut Protein Assay Kit (Tepnel). Each gram of the aqueous peanut butter suspension contained 20 mg carboxymethylcellulose sodium salt, 643 microg peanut, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. The suspension was homogenous, stable, reproducible, and applicable for adding to ice cream, cookies, breakfast cereals, and chocolate for recovery studies at spike levels ranging from 12 to 90 microg/g.
Comparison of three multiplex cytokine analysis systems: Luminex, SearchLight and FAST Quant.
Lash, Gendie E; Scaife, Paula J; Innes, Barbara A; Otun, Harry A; Robson, Steven C; Searle, Roger F; Bulmer, Judith N
2006-02-20
Multiplex cytokine analysis technologies have become readily available in the last five years. Two main formats exist: multiplex sandwich ELISA and bead based assays. While these have each been compared to individual ELISAs, there has been no direct comparison between the two formats. We report here the comparison of two multiplex sandwich ELISA procedures (FAST Quant and SearchLight) and a bead based assay (UpState Luminex). All three kits differed from each other for different analytes and there was no clear pattern of one system giving systematically different results than another for any analyte studied. We suggest that each system has merits and several factors including range of analytes available, prospect of development of new analytes, dynamic range of the assay, sensitivity of the assay, cost of equipment, cost of consumables, ease of use and ease of data analysis need to be considered when choosing a system for use. We also suggest that results obtained from different systems cannot be combined.
Robinson, Andrew L; Lee, Hyun Jung; Ryu, Dojin
2017-01-01
Ochratoxin A (OTA) is a fungal metabolite and putative carcinogen which can contaminate a variety of foods such as cereals, wine, and nuts. Commercial ELISA kits are known to give false-positive results for OTA concentrations when phenolic compounds are present. Pistachios represent a food matrix rich in phenolic compounds potentially contaminated with OTA, and were used to model OTA cross-reactivity. Polyvinylpolypyrrolidone (PVPP) was incorporated during extraction of OTA using a commercial ELISA protocol. HPLC methods were used to confirm that PVPP does not interact with OTA and levels of gallic acid and catechin remaining in pistachio extracts decreased with increasing PVPP application. Cross-reactivity of extracts also decreased with increasing PVPP application, and color loss was used as an indicator of anthocyanin removal. Incorporating PVPP into ELISA protocols allows for the continued use of rapid immunological methods in food matrices containing phenolic compounds. Copyright © 2016 Elsevier Ltd. All rights reserved.
Comparison of serum and plasma measurements of Müllerian inhibiting substance.
Merhi, Zaher O; Messerlian, Geralyn M; Minkoff, Howard; Eklund, Elizabeth E; Macura, Jerzy; Feldman, Joseph; Rodriguez, Carlos; Seifer, David B
2008-06-01
The authors sought to determine whether measurement of plasma Müllerian inhibiting substance (MIS) is a suitable substitute for measurement of serum MIS. Eighteen samples of serum and plasma were examined that were drawn simultaneously. Levels of MIS were measured with an ELISA kit, and plasma levels were studied in parallel to serum samples. A 98.5% correlation was found between serum and plasma MIS values.
Prevalence of HTLV-1 Antibody among Major Thalassemic Patients in Gorgan (South East of Caspian Sea)
NASA Astrophysics Data System (ADS)
Moradi, A.; Mansurian, A. R.; Ahmadi, A. R.; Ghaemi, E.; Kalavi, K. H.; Marjani, A.; Sanei Moghaddam, E.
In this study, the prevalence of HTLV-1 infection among the thalassemic patients was investigated. 181 thalassemic patients whom referred to Talghani hospital during, Oct. 2004-Sep. 2005 were participated in this study. HTLV antibody was determined using ELISA technique. In this procedure (Diapron laboratory kit) HTLV, positive samples tested by HTLV-1 western blot (kit, 2.4) to confirm, ELISA positive samples and also to detect the HTLV types. From 181 thalassemic patients, 93 (51.4%) were males. The age rate of these ranged 1-25 years, (mean of 14.11±6.5). Of these subjects 169 patients (93.4%) were received packet cell at least one unite per month. 28(14.9%) of subjects were HTLV positive, while only 4.4% of them were confirmed by western blot and also for contamination with type-1 virus infection. Contamination with this virus increased, as the patients were getting older. The findings derived from this study indicated that among the thalassemic patients in Gorgan there were cases with HTLV-1, infection that was correlated with the other part of the country. It is therefore concluded; that further comprehensive studies are required to identify infected blood donations by blood donors in Gorgan.
Garcia, L S; Shimizu, R Y
1997-01-01
It is well known that Giardia lamblia and Cryptosporidium parvum can cause severe symptoms in humans, particularly those who are immunologically compromised. Immunoassay procedures offer both increased sensitivity and specificity compared to conventional staining methods. These reagents are also helpful when screening large numbers of patients, particularly in an outbreak situation or when screening patients with minimal symptoms. The data obtained by using 9 diagnostic kits were compared: direct fluorescent-antibody assay (DFA) kits (TechLab Giardia/Crypto IF kit, TechLab Crypto IF kit, and Meridian Merifluor Cryptosporidium/Giardia) and enzyme immunoassay (EIA) kits (Alexon ProSpecT Giardia EZ Microplate Assay, Alexon ProSpecT Cryptosporidium Microplate Assay, Cambridge Giardia lamblia Antigen Microwell ELISA, Meridian Premier Giardia lamblia, Meridian Premier Cryptosporidium, TechLab Giardia CELISA, Trend Giardia lamblia EIA). The test with the Meridian Merifluor Cryptosporidium/Giardia kit was used as the reference method. In various combinations, 60 specimens positive for Giardia, 60 specimens positive for Cryptosporidium, 40 specimens positive for a Giardia-Cryptosporidium mix, and 50 negative fecal specimens were tested. Different species (nine protozoa, three coccidia, one microsporidium, five nematodes, three cestodes, and one trematode) were included in the negative specimens. The sensitivity of EIA for Giardia ranged from 94% (Alexon) to 99% (Trend and Cambridge); the specificity was 100% with all EIA kits tested. The sensitivity of EIA for Cryptosporidium ranged from 98% (Alexon) to 99% (Meridian Premier); specificities were 100%. All DFA results were in agreement, with 100% sensitivity and specificity; however, the TechLab reagents resulted in fluorescence intensity that was generally one level below that seen with the reagents used in the reference method. In addition to sensitivity and specificity, factors such as cost, simplicity, ease of interpretation of results (color, intensity of fluorescence), equipment, available personnel, and number of tests ordered are also important considerations prior to kit selection. PMID:9163474
Deng, Jingjing; Yang, Shu; Yuan, Qing; Chen, Yuzhong; Li, Dandan; Sun, Haimei; Tan, Xinghua; Zhang, Fuchun; Zhou, Deshan
2017-01-01
Acupuncture is a therapy effective in treating postoperative ileus (POI); its underlying mechanisms remain unclear. MicroRNAs (miRNAs) participate in inflammation and injury to the interstitial cells of Cajal (ICCs), both of which are considered to be contributors to POI. C-kit, encoding KIT, a specific marker of ICCs, is predicted to be targeted by miR-19a, an inflammation-related miRNA. Therefore, we investigated a possible link between inflammation, miR-19a, and ICCs in POI, as well as the mechanism by which these factors are affected by acupuncture. The effects of acupuncture on POI were assessed in patients after colorectal resection and in colocolic anastomosis mice. Immunofluorescence staining demonstrated that KIT[Formula: see text]/ano1[Formula: see text] ICCs dramatically decreased around the colonic incision in mice, which was negatively correlated with the pronounced increase in macrophage. However, this decrease was not due to apoptosis. IL-6R was expressed in ICCs, and IL-6 level was significantly increased, as measured by ELISA, in accompaniment with high miR-19a expression. The increase in IL-6 and miR-19a levels was negatively correlated with the decrease in KIT[Formula: see text]/ano1[Formula: see text] ICCs. A luciferase reporter assay demonstrated that miR-19a directly targeted C-kit, indicating that miR-19a caused ICC damage. Interestingly, acupuncture inhibited macrophage activation, IL-6 release, and miR-19a upregulation, while promoting KIT and ano1 restoration in ICCs. High serum miR-19a level in patients after colorectal resection was also reduced by acupuncture. Conclusively, the IL-6 released by macrophages during gastrointestinal surgery upregulated miR-19a, which downregulated KIT in ICCs and finally resulted in POI. Acupuncture can interfere with the "IL-6-miR-19a-KIT" axis, suggesting that it may be a therapeutic mechanism that works against POI.
ELISA assays and alcohol: increasing carbon chain length can interfere with detection of cytokines
von Maltzan, Kristine; Pruett, Stephen B.
2010-01-01
Enzyme-linked immunosorbent assays (ELISA) are frequently used in studies on cytokine production in response to treatment of cell cultures or laboratory animals. When an ELISA assay is performed on cell culture supernatants, samples often contain the treatment agents. The purpose of the present study was to determine if some of the agents evaluated might inhibit cytokine detection by interfering with the ELISA, leaving the question of whether cytokine production was inhibited unanswered. Mouse and human cytokine ELISA kits from BD Biosciences were used according to the manufacturer’s instructions. Cytokine proteins were subjected to one to five carbon alcohols at 86.8 mM (methanol, ethanol, 1-propanol, 2-propanol, n-butanol, and n-pentanol). After treating cell cultures with alcohols of different carbon chain lengths, we found that some of the alcohols interfered with measurement of some cytokines by ELISA, thus making their effects on cytokine production by cells in culture unclear. Increasing carbon chain length of straight chain alcohols positively correlated with their ability to inhibit detection of TNF-α and IL-10, but not with the detection of IL-6, IL-8, and IL-12. To avoid misinterpretation of treatment effects, ELISA assays should be tested with the reference protein and the treatment agent first, before testing biological samples. These results along with other recent results we obtained using circular dichroism indicate that alcohols with 2 or more carbons can directly alter protein conformation enough to disrupt binding in an ELISA (shown in the present study) or to inhibit ligand induced conformational changes (results not shown). Such direct effects have not been given enough consideration as a mechanism of ethanol action in the immune system. PMID:20843633
Pagnon, Anke; Piras, Fabienne; Gimenez-Fourage, Sophie; Dubayle, Joseline; Arnaud-Barbe, Nadège; Hessler, Catherine; Caillet, Catherine
2017-11-01
In clinical trials of cytomegalovirus (CMV) glycoprotein B (gB) vaccines, CMV infection is detected by first depleting serum of anti-gB antibodies and then measuring anti-CMV antibodies with a commercially available enzyme-linked immunosorbent assay (ELISA) kit, with confirmation of positive findings by immunoblot. Identification of CMV immunoantigens for the development of an ELISA that detects specifically CMV infection in clinical samples from individuals immunized with gB vaccines. Sensitivity and specificity of ELISAs using antigenic regions of CMV proteins UL83/pp65, UL99/pp28, UL44/pp52, UL80a/pp38, UL57, and UL32/pp150 were measured. An IgG ELISA using a UL32/pp150 [862-1048] capture peptide was the most specific (93.7%) and sensitive (96.4%) for detecting CMV-specific antibodies in sera. The ELISA successfully detected CMV-specific antibodies in 22 of 22 sera of subjects who had been vaccinated with a gB vaccine but who had later been infected with CMV. The ELISA was linear over a wide range of CMV concentrations (57-16,814 ELISA units/mL) and was reproducible as indicated by a 5% intra-day and 7% inter-day coefficients of variation. The signal was specifically competed by UL32/pp150 [862-1048] peptide but not by CMV-gB or herpes simplex virus 2 glycoprotein D. Lipid and hemoglobin matrix did not interfere with the assay. The UL32/pp150 [862-1048] IgG ELISA can be used for the sensitive and specific detection of CMV infection in gB-vaccinated individuals. Copyright © 2017 Elsevier B.V. All rights reserved.
Jang, J-H; Jung, Y M; Kim, J S; Lee, S H; Kim, J-W; Hwang, S G; Rim, K S; Park, S J; Park, Y M; Kang, S-K; Lee, H S; Yun, H; Kim, J-H; Jeong, S-H
2011-10-01
This study investigated the clinical, serological and molecular characteristics of coexistence of both immunoglobulin M (IgM) antihepatitis A virus (HAV) and IgM antihepatitis E virus (HEV) in acute viral hepatitis using a prospective, multicentre design. Among a total of 771 symptomatic cases with acute viral hepatitis enrolled in a Korean city from September 2006 to August 2008, coexistence of IgM anti-HAV and IgM anti-HEV was found in 43 patients (A+E group; 6%), while the existence of IgM anti-HAV alone was found in 595 patients (A group; 77%) and that of IgM anti-HEV alone in 14 patients (E group; 2%). Clinical data analysis and measurement of IgM and IgG anti-HEV were performed using two different commercial kits, and HAV RNA and HEV RNA were detected in available serum or stool samples. The clinical features of the A+E group were similar to those of the A group. HAV RNA detection rates in the A+E and A group were similar, while HEV RNA was detected only in the stool samples of the E group, not in the A+E group. Comparative testing of anti-HEV using two different ELISA kits showed markedly discordant results for IgM anti-HEV positivity and consistently low positivity for IgG anti-HEV in the A+E group. Coexistence of IgM anti-HEV measured by the Genelabs ELISA kit in the setting of hepatitis A appears to yield false-positive results in nonendemic areas of HEV infection. Diagnosis of hepatitis E using IgM anti-HEV should be made with caution. © 2011 Blackwell Publishing Ltd.
Serological levels of apoptotic bodies, sFAS and TNF in lupus erythematosus.
Alecu, M; Coman, G; Alecu, S
In our study we have investigated the presence of apoptotic bodies, soluble FAS receptor and TNF (tumor necrosis factor) in three clinical forms of lupus erythematosus. Determinations were performed in attack period of: systemic lupus erythematosus (SLE) for 20 patients, 20 patients with subacute cutaneous lupus erythematosus (SCLE), 20 patients with chronic discoid lupus erythematosus (DLE). Determinations were performed by ELISA (for apoptotic bodies, kit Boehringer, normal values 400-800 mU), (for sFAS, kit R&D Systems, normal values 4500-17000 pg/ml) (for TNF, ELISA kit R&D Systems, normal values 0.4-3.6 pg/ml). Results in SLE: apoptotic bodies were increased in 16 cases (980-1030); sFAS in 18 cases (17000-24000 pg/ml) TNF was increased in all 20 cases (40-140 pg/ml). In SCLE with multiple cutaneous lesions and without internal organs disturbance the apoptotic bodies were increased in 10 cases (960-1030 pg/ml), sFAS in 9 cases (17000-22000 pg/ml), and TNF alpha in 9 cases. In DLE, apoptotic bodies were increased in 2 patients (980-1010 pg/ml), sFAS in 3 patients (17000-20000 pg/ml) and TNF in 2 patients (20-40 pg/mil). Investigated values were slightly correlated with immune parameters (anti dsDNA antibodies), but they were correlated with the presence of renal disturbances or extension of cutaneous lesions. We consider that the presence of increased apoptotic bodies as a result of peripheral mononuclear cells apoptosis appear as a nauto-limiting mechanism in a pathological immune response. The increase of sFAS in lupus patients serum might be interpreted as an alteration of apoptosis respectively a deficit in apoptosis which has as a first consequence the persistence of B and T lymphocytes, activated, in the pathogen immune response.
CSF biomarker variability in the Alzheimer’s Association quality control program
Mattsson, Niklas; Andreasson, Ulf; Persson, Staffan; Carrillo, Maria C.; Collins, Steven; Chalbot, Sonia; Cutler, Neal; Dufour-Rainfray, Diane; Fagan, Anne M.; Heegaard, Niels H. H.; Hsiung, Ging-Yuek Robin; Hyman, Bradley; Iqbal, Khalid; Lachno, D. Richard; Lleó, Alberto; Lewczuk, Piotr; Molinuevo, José L.; Parchi, Piero; Regeniter, Axel; Rissman, Robert; Rosenmann, Hanna; Sancesario, Giuseppe; Schröder, Johannes; Shaw, Leslie M.; Teunissen, Charlotte E.; Trojanowski, John Q.; Vanderstichele, Hugo; Vandijck, Manu; Verbeek, Marcel M.; Zetterberg, Henrik; Blennow, Kaj; Käser, Stephan A.
2013-01-01
Background The cerebrospinal fluid (CSF) biomarkers amyloid beta 1–42, total tau, and phosphorylated tau are used increasingly for Alzheimer’s disease (AD) research and patient management. However, there are large variations in biomarker measurements among and within laboratories. Methods Data from the first nine rounds of the Alzheimer’s Association quality control program was used to define the extent and sources of analytical variability. In each round, three CSF samples prepared at the Clinical Neurochemistry Laboratory (Mölndal, Sweden) were analyzed by single-analyte enzyme-linked immunosorbent assay (ELISA), a multiplexing xMAP assay, or an immunoassay with electrochemoluminescence detection. Results A total of 84 laboratories participated. Coefficients of variation (CVs) between laboratories were around 20% to 30%; within-run CVs, less than 5% to 10%; and longitudinal within-laboratory CVs, 5% to 19%. Interestingly, longitudinal within-laboratory CV differed between biomarkers at individual laboratories, suggesting that a component of it was assay dependent. Variability between kit lots and between laboratories both had a major influence on amyloid beta 1–42 measurements, but for total tau and phosphorylated tau, between-kit lot effects were much less than between-laboratory effects. Despite the measurement variability, the between-laboratory consistency in classification of samples (using prehoc-derived cutoffs for AD) was high (>90% in 15 of 18 samples for ELISA and in 12 of 18 samples for xMAP). Conclusions The overall variability remains too high to allow assignment of universal biomarker cutoff values for a specific intended use. Each laboratory must ensure longitudinal stability in its measurements and use internally qualified cutoff levels. Further standardization of laboratory procedures and improvement of kit performance will likely increase the usefulness of CSF AD biomarkers for researchers and clinicians. PMID:23622690
Orejarena Ávila, Lina Paola; Inguilan Benavides, Erika Marcela; Padilla Sanabria, Leonardo; Recalde-Reyes, Delia Piedad; Rodríguez-Salazar, Carlos Andrés; Castaño-Osorio, Jhon Carlos
2018-03-01
Fasciolosis is a zoonotic parasitic disease, which affects humans and animals; diagnosed through noncommercial immunoassay tests that cannot be used on the field. Thereby, establishing the optimal conditions to develop a latex agglutination technique with IgG and IgM antibodies directed against excretion/secretion antigens of Fasciola sp. is a priority. Latex particles were sensitized with IgG and IgM antibodies directed against excretion/secretion antigens of Fasciola sp. The specificity of the antibodies was determined against antigens of different helminths and protozoa; the sensitivity and specificity of the test was evaluated against a previously standardized direct ELISA. The coupling rates of the IgG and IgM antibodies were 85.77 and 100%, respectively. The minimum detectable concentration of Fasciola sp. excretion/secretion antigens, diluted in a phosphate-buffered saline, was 1.589 mg/mL(IgG) and 0.158 mg/mL(IgM) and for the antigens incorporated in the bovine cattle stool it was 3.178 mg/mL(IgG) and 1.589 mg/mL(IgM). The test showed crossed reaction against Giardia sp., and Cryptosporidium sp. antigens. Agreement of the IgG and IgM latex test against the ELISA test was of 78.78 and 96.96%, respectively; the specificity found was of 100% for both tests and sensitivity was 78.79% (IgG) and 96.97% (IgM). This work standardized the latex agglutination technique to detect Fasciola sp. antigens in bovine cattle stool.
Mirkalantari, Shiva; Zarnani, Amir-Hassan; Nazari, Mahboobeh; Irajian, Gholam Reza; Amirmozafari, Nour
2017-03-03
The numerous drawbacks of current serological tests for diagnosis of brucellosis which mainly results from cross reactivity with LPS from other gram-negative bacteria have generated an increasing interest to find more specific non-LPS antigens. Previous studies had indicated that Brucella VirB12 protein, a cell surface protein and component of type IV secretion system, induces antibody response during animal infection. However, this protein has not yet been tested as a serological diagnostic marker in human brucellosis. Recombinant VirB12 protein was prepared and evaluated the efficacy of it in an indirect enzyme-linked immunosorbent assay (ELISA) for brucellosis with sera collected from different region of Iran and the results were compared with a commercial ELISA kit. Sera from human brucellosis patients strongly reacted to the purified recombinant VirB12. The sensitivity, specificity, accuracy, negative predictive value and positive predictive value of recombinant VirB12-based ELISA related to the commercial-ELISA method were 87.8, 94, 90, 80 and 96.6% respectively. We concluded that antigenic VirB12 have a property value that can be considered as a candidate for using in serodiagnostic tests for human brucellosis.
A monoclonal antibody based elisa for quantitation of human leukaemia inhibitory factor.
Taupin, J L; Gualde, N; Moreau, J F
1997-02-01
The authors report on the development of a new sandwich enzyme-linked immunoabsorbent assay (ELISA) for the quantitation of the human cytokine leukaemia inhibitory factor/human interleukin for DA cells (LIF/HILDA) with high accuracy and sensitivity (23 pg/ml), in less than 5 h and in various biological fluids. The antibodies used in this assay were raised against recombinant glycosylated LIF expressed in vivo following inoculation of recombinant vaccinia viruses, and screened with the biologically active cytokine in a flow cytometry assay using cells expressing a membrane-bound form of LIF. Furthermore, this home-made assay was compared with two commercially available ELISA kits. The results led to the conclusion that these three assays are far from being equivalent between each other, in terms of sensitivity towards non-glycosylated vs glycosylated LIF. Two major parameters must be incriminated: the glycosylation status of the LIF molecule used as the calibrator, and the binding characteristics of the monoclonal antibodies used to set up these assays toward LIF derived from Escherichia coli or from eukaryotic cells. This points out the importance of these parameters for the design of ELISAs meant for the quantitation of glycosylated cytokines in biological fluids.
Yue, Chao-Yan; Ying, Chun-Mei
2017-01-01
To explore the effect of modified enzyme-linked immunosorbent assay on the AMH results is increased or decreased, and to investigate the effect of storage time and temperature on AMH measurements with and without sample premixing assay buffer using the Kangrun ELISA method. Serum AMH concentration were measured by ELISA, consistency between two kits, and comparability between original and the modified assay under different stored conditions were analyzed by Passing-Bablok regression analysis and Bland-Altman bias evaluation. There was a strong consistency between AMH concentrations measured in Kangrun ELISA and Ansh Labs ultra-sensitive AMH ELISA. Pre-mixing serum specimens with assay buffer gave consistent results compared with original assay. Modified protocol can reduce the amplitude of increase affected by sample aged and give the most consistent results regardless of storage conditions. Pre-mixing protocol did not influence the results of fresh serum or frozen serum incubation <3days at 4°C and -80°C, but when specimens detected after collection and stored in other storage conditions, should be pre-mixed with assay buffer to insure its accuracy. Copyright © 2016 Elsevier B.V. All rights reserved.
Roelandt, S; Van der Stede, Y; Czaplicki, G; Van Loo, H; Van Driessche, E; Dewulf, J; Hooyberghs, J; Faes, C
2015-06-06
Currently, there are no perfect reference tests for the in vivo detection of Neospora caninum infection. Two commercial N caninum ELISA tests are currently used in Belgium for bovine sera (TEST A and TEST B). The goal of this study is to evaluate these tests used at their current cut-offs, with a no gold standard approach, for the test purpose of (1) demonstration of freedom of infection at purchase and (2) diagnosis in aborting cattle. Sera of two study populations, Abortion population (n=196) and Purchase population (n=514), were selected and tested with both ELISA's. Test results were entered in a Bayesian model with informative priors on population prevalences only (Scenario 1). As sensitivity analysis, two more models were used: one with informative priors on test diagnostic accuracy (Scenario 2) and one with all priors uninformative (Scenario 3). The accuracy parameters were estimated from the first model: diagnostic sensitivity (Test A: 93.54 per cent-Test B: 86.99 per cent) and specificity (Test A: 90.22 per cent-Test B: 90.15 per cent) were high and comparable (Bayesian P values >0.05). Based on predictive values in the two study populations, both tests were fit for purpose, despite an expected false negative fraction of ±0.5 per cent in the Purchase population and ±5 per cent in the Abortion population. In addition, a false positive fraction of ±3 per cent in the overall Purchase population and ±4 per cent in the overall Abortion population was found. British Veterinary Association.
Cursino, Sylvia Regina Temer; da Costa, Thaís Boccia; Yamamoto, Joyce Hisae; Meireles, Luciana Regina; Silva, Maria Antonieta Longo Galvão; de Andrade Junior, Heitor Franco
2010-01-01
PURPOSE: To search for anti-retina antibodies that serve as markers for eye disease in uveitis. MATERIALS AND METHODS: Stored sera from patients with uveitis, ocular toxoplasmosis (n = 30) and non-infectious, immune-mediated uveitis (n = 50) and from asymptomatic individuals who were positive (n = 250) and negative (n = 250) for anti-Toxoplasma antibodies were tested. Serum anti-retina IgG was detected by an optimized ELISA using a solid-phase whole human retina extract, bovine S-antigen or interphotoreceptor retinoid-binding protein. RESULTS: Uveitis patients showed a higher mean reactivity to whole human retina extract, interphotoreceptor retinoid-binding protein and S-antigen in comparison to the asymptomatic population. These findings were independent of the uveitis origin and allowed the determination of the lower anti-retina antibody cut-off for the three antigens. Asymptomatic anti-Toxoplasma serum-positive individuals showed a higher frequency of anti-human whole retina extract antibodies in comparison to asymptomatic anti-Toxoplasma serum-negative patients. The bovine S-antigen and interphotoreceptor retinoid-binding protein ELISAs also showed a higher mean reactivity in the uveitis groups compared to the asymptomatic group, but the observed reactivities were lower and overlapped without discrimination. CONCLUSION: We detected higher levels of anti-retina antibodies in uveitis patients and in a small fraction of asymptomatic patients with chronic toxoplasmosis. The presence of anti-retina antibodies in sera might be a marker of eye disease in asymptomatic patients, especially when whole human retina extract is used in a solid-phase ELISA. PMID:21120306
Production and characterization of egg yolk antibody (IgY) against recombinant VP8-S2 antigen.
Nasiri, K; Nassiri, M R; Tahmoorespur, M; Haghparast, A; Zibaee, S
2016-01-01
Bovine Rotavirus and Bovine Coronavirus are the most important causes of diarrhea in newborn calves and in some other species such as pigs and sheep. VP8 subunit of rotavirus is the major determinant of the viral infectivity and neutralization. Spike glycoprotein of coronavirus is responsible for induction of neutralizing antibody response. Studies showed that immunoglobulin of egg yolk (IgY) from immunized hens has been identified to be a convenient source for specific antibodies for using in immunotherapy and immunodiagnostic to limit the infections. In this study, chimeric VP8-S2 gene was designed using by computational techniques. The chimeric VP8-S2 gene was cloned and sub-cloned into pGH and pET32a (+) vectors. Then, recombinant pET32a-VP8-S2 vector was transferred into E. coli BL21 CodonPlus (DE3). The expressed protein was purified by Ni-NTA chromatography column. Hens were immunized with the purified VP8-S2 protein three times. IgY was purified from egg yolks using polyethylene glycol precipitation method. Activity and specificity of anti-VP8-S2 IgY were detected by dot-blotting, Western-blotting and indirect ELISA. We obtained anti-VP8-S2 IgY by immunizing hens with the recombinant VP8-S2 protein. The anti-VP8-S2 IgY was showed to bind specifically to the chimeric VP8-S2 protein by dot-blotting, Western-blotting analyses and indirect ELISA. The result of this study indicated that such construction can be useful to investigate as candidates for development of detection methods for simultaneous diagnosis of both infections. Specific IgY against the recombinant VP8-S2 could be recommended as a candidate for passive immunization against bovine rotavirus and bovine coronavirus.
Goossens, Evy; Verherstraeten, Stefanie; Valgaeren, Bonnie R; Pardon, Bart; Timbermont, Leen; Schauvliege, Stijn; Rodrigo-Mocholí, Diego; Haesebrouck, Freddy; Ducatelle, Richard; Deprez, Piet R; Van Immerseel, Filip
2016-06-13
Bovine necrohemorrhagic enteritis is caused by Clostridium perfringens type A. Due to the rapid progress and fatal outcome of the disease, vaccination would be of high value. In this study, C. perfringens toxins, either as native toxins or after formaldehyde inactivation, were evaluated as possible vaccine antigens. We determined whether antisera raised in calves against these toxins were able to protect against C. perfringens challenge in an intestinal loop model for bovine necrohemorrhagic enteritis. Alpha toxin and perfringolysin O were identified as the most immunogenic proteins in the vaccine preparations. All vaccines evoked a high antibody response against the causative toxins, alpha toxin and perfringolysin O, as detected by ELISA. All antibodies were able to inhibit the activity of alpha toxin and perfringolysin O in vitro. However, the antibodies raised against the native toxins were more inhibitory to the C. perfringens-induced cytotoxicity (as tested on bovine endothelial cells) and only these antibodies protected against C. perfringens challenge in the intestinal loop model. Although immunization of calves with both native and formaldehyde inactivated toxins resulted in high antibody titers against alpha toxin and perfringolysin O, only antibodies raised against native toxins protect against C. perfringens challenge in an intestinal loop model for bovine necrohemorrhagic enteritis.
SP-A binding sites on bovine alveolar macrophages.
Plaga, S; Plattner, H; Schlepper-Schaefer, J
1998-11-25
Surfactant protein A (SP-A) binding to bovine alveolar macrophages was examined in order to characterize SP-A binding proteins on the cell surface and to isolate putative receptors from these cells that could be obtained in large amounts. Human SP-A, unlabeled or labeled with gold particles, was bound to freshly isolated macrophages and analyzed with ELISA or the transmission electron microscope. Binding of SP-A was inhibited by Ca2+ chelation, by an excess of unlabeled SP-A, or by the presence of 20 mg/ml mannan. We conclude that bovine alveolar macrophages expose binding sites for SP-A that are specific and that depend on Ca2+ and on mannose residues. For isolation of SP-A receptors with homologous SP-A as ligand we isolated SP-A from bovine lung lavage. SDS-PAGE analysis of the purified SP-A showed a protein of 32-36 kDa. Functional integrity of the protein was demonstrated. Bovine SP-A bound to Dynabeads was used to isolate SP-A binding proteins. From the fractionated and blotted proteins of the receptor preparation two proteins bound SP-A in a Ca2+-dependent manner, a 40-kDa protein showing mannose dependency and a 210-kDa protein, showing no mannose sensitivity. Copyright 1998 Academic Press.
Butterworth, Alice S; Robertson, Alan J; Ho, Mei-Fong; Gatton, Michelle L; McCarthy, James S; Trenholme, Katharine R
2011-04-18
Obtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth is an arduous and labor-intensive process. An alternative method for the detection of parasite growth in limiting dilution assays is using a commercial ELISA histidine-rich protein II (HRP2) detection kit. Detection of parasite growth was undertaken using HRP2 ELISA and compared to thick film microscopy. An HRP2 protein standard was used to determine the detection threshold of the HRP2 ELISA assay, and a HRP2 release model was used to extrapolate the amount of parasite growth required for a positive result. The HRP2 ELISA was more sensitive than microscopy for detecting parasite growth. The minimum level of HRP2 protein detection of the ELISA was 0.11 ng/ml. Modeling of HRP2 release determined that 2,116 parasites are required to complete a full erythrocytic cycle to produce sufficient HRP2 to be detected by the ELISA. Under standard culture conditions this number of parasites is likely to be reached between 8 to 14 days of culture. This method provides an accurate and simple way for the detection of parasite growth in limiting dilution assays, reducing time and resources required in traditional methods. Furthermore the method uses spent culture media instead of the parasite-infected red blood cells, enabling culture to continue. © 2011 Butterworth et al; licensee BioMed Central Ltd.
Kalaiyarasu, Semmannan; Mishra, Niranjan; Rajukumar, Katherukamem; Nema, Ram Kumar; Behera, Sthita Pragnya
2015-01-01
The aim of this study was to develop an indirect ELISA using the helicase domain of bovine viral diarrhoea virus (BVDV) NS3 protein instead of full-length NS3 protein for detection of BVDV and BDV antibodies in sheep and goats and its validation by comparing its sensitivity and specificity with virus neutralization test (VNT) as the reference test. The purified 50 kDa recombinant NS3 protein was used as the coating antigen in the ELISA. The optimal concentration of antigen was 320 ng/well at a serum dilution of 1:20 and the optimal positive cut-off optical density value was 0.40 based on test results of 418 VNT negative sheep and goat sera samples. When 569 serum samples from sheep (463) and goats (106) were tested, the ELISA showed a sensitivity of 91.71% and specificity of 94.59% with BVDV VNT. A good correlation (93.67%) was observed between the two tests. It showed a sensitivity of 85% and specificity of 86.6% with VNT in detecting BDV antibody positive or negative samples. This study demonstrates the efficacy of truncated recombinant NS3 antigen based ELISA for seroepidemiological study of pestivirus infection in sheep and goats.
Loeffler, David A; Klaver, Andrea C
2017-11-01
Specific antibody concentrations are frequently measured in serum (and plasma and intravenous immunoglobulin) samples by enzyme-linked immunosorbent assay (ELISA). The standard negative control involves incubation of buffer alone on antigen-coated wells. The immunoreactivity that develops in antigen-coated wells in which diluted serum has been incubated is assumed to represent specific antibody binding. This approach can result in marked overestimation of specific antibody levels, because serum contains specific polyvalent antibodies which bind, primarily with low affinity, to multiple antigens (including those on ELISA plates) despite the use of blocking agents. Non-denaturing purification of serum IgG, followed by assessment of the antigen binding or antigen-binding affinity of this purified IgG, can reduce but not eliminate the problem of polyvalent antibody binding in indirect ELISAs. Alternatively, polyvalent antibody binding can be estimated by incubating a diluted serum sample on wells coated with an irrelevant protein (such as bovine serum albumin or a scrambled peptide sequence) or buffer alone, then subtracting this reactivity from the sample's binding to wells coated with the antigen of interest. Polyvalent binding of immunoglobulins must be accounted for in order to obtain accurate ELISA measurements of serum, plasma, or intravenous immunoglobulin antibodies. Copyright © 2017 Elsevier B.V. All rights reserved.
Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S
2014-07-01
Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.
The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7.
Wang, Shun; Xie, Jiufeng; Jiang, Min; Chang, Keke; Chen, Ruipeng; Ma, Liuzheng; Zhu, Juanhua; Guo, Qingqian; Sun, Haifeng; Hu, Jiandong
2016-11-04
The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent -CO-NH- amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 10³ cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field.
Meyer, Sven; Adam, Matti; Schweiger, Brunhilde; Ilchmann, Corina; Eulenburg, Christine; Sattinger, Edgar; Runte, Hendrik; Schlüter, Michael; Deuse, Tobias; Reichenspurner, Hermann; Costard-Jäckle, Angelika
2011-05-15
Influenza A (H1N1) has emerged as a considerable threat for recipients of organ transplants. Vaccination against the novel influenza A (H1N1) virus has generally been advocated. There is limited experience with AS03-adjuvanted A/H1N1 pandemic influenza vaccines in immunosuppressed patients. We conducted an observational, nonrandomized single-center study to assess antibody response and vaccine-related adverse effects in 47 heart transplant recipients (44 men; age, 56±13 years). The AS03-adjuvanted, inactivated split-virion A/California/7/2009 H1N1v pandemic vaccine was administered. Antibody titers were measured using hemagglutination inhibition; immunoglobulin G (IgG) response was assessed using a new pandemic influenza A IgG enzyme-linked immunosorbent assay (ELISA) test kit and compared with hemagglutination-inhibition titers. Adverse effects of vaccination were assessed by a questionnaire. Postvaccination antibody titers of greater than or equal to 1:40 were found in only 15 patients, corresponding to a seroprotection rate of 32% (95% confidence interval, 19%-47%). Sensitivity, specificity, positive predictive value, and negative predictive value of ELISA testing were 80.0%, 68.8%, 54.5%, and 88.0%, respectively. Age, time posttransplantation, and immunosuppressive regimen did not impact antibody response. Vaccination was well tolerated. Single-dose administration of an AS03-adjuvanted vaccine against the novel influenza A (H1N1) virus did not elicit seroprotective antibody concentrations in a substantial proportion of heart transplant recipients; the new pandemic influenza A IgG ELISA test kit proved to be of limited clinical use.
The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7
Wang, Shun; Xie, Jiufeng; Jiang, Min; Chang, Keke; Chen, Ruipeng; Ma, Liuzheng; Zhu, Juanhua; Guo, Qingqian; Sun, Haifeng; Hu, Jiandong
2016-01-01
The purpose of this study was to develop a portable surface plasmon resonance (SPR) bioanalyzer for the sensitive detection of Escherichia coli O157:H7 in comparison with an enzyme-linked immunosorbent assay (ELISA). The experimental setup mainly consisted of an integrated biosensor and a homemade microfluidic cell with a three-way solenoid valve. In order to detect Escherichia coli O157:H7 using the SPR immunoassay, 3-mercaptopropionic acid (3-MPA) was chemisorbed onto a gold surface via covalent bond for the immobilization of biological species. 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) and N-hydroxysuccinimide (NHS) were used as crosslinker reagents to enable the reaction between 3-MPA and Escherichia coli O157:H7 antibodies by covalent –CO–NH– amide bonding. The experimental results were obtained from the Escherichia coli O157:H7 positive samples prepared by 10-, 20-, 40-, 80-, and 160-fold dilution respectively, which show that a good linear relationship with the correlation coefficient R of 0.982 existed between the response units from the portable SPR bioanalyzer and the concentration of Escherichia coli O157:H7 positive samples. Moreover, the theoretical detection limit of 1.87 × 103 cfu/mL was calculated from the positive control samples. Compared with the Escherichia coli O157:H7 ELISA kit, the sensitivity of this portable SPR bioanalyzer is four orders of magnitude higher than the ELISA kit. The results demonstrate that the portable SPR bioanalyzer could provide an alternative method for the quantitative and sensitive determination of Escherichia coli O157:H7 in field. PMID:27827923
USDA-ARS?s Scientific Manuscript database
Toxoplasmosis is a parasitic infection of humans and animals and it continues to be public health and food safety issue. Among the many ways this infection is acquired, the consumption of unpasteurized goat cheese and milk has been suggested as a risk factor for toxoplasmosis in humans. Although pas...
J.B. Fischer; J.L. Michael
1997-01-01
The herbicide triclopyr (3,5,6-trichloro-2-pyridinyl)-oxyacetic acid has been marketed by the Dow Chemical Co. since the mid 1970's as the triethylammonium salt (Garlon 3A) and as the ethylene glycol butyl ether ester (Garlon 4). Shortly after its introduction, McKellar (1977) published a method for the extraction, isolation, and electron capture gas...
2017-10-01
found in joints, develop in the early stages of CIA creating neo-antigens that further boost the "epitope spreading" during the autoimmune response(8...ready-made ELISA kits. (eBioscience Inc.). We find that at the early stages of arthritis development FTS significantly reduces the upregulation of...reprints of manuscripts and abstracts, a curriculum vitae, patent applications, study questionnaires, and surveys , etc. “Nothing to Report
Vongxay, Khamphouth; Conlan, James V; Khounsy, Syseng; Dorny, Pierre; Fenwick, Stanley; Thompson, R C Andrew; Blacksell, Stuart D
2012-10-01
Bovine-associated zoonotic infectious diseases pose a significant threat to human health in the Lao People's Democratic Republic (Lao PDR). In all, 905 cattle and buffalo serum samples collected in northern Lao PDR in 2006 were used to determine seroprevalence of five major bovine zoonotic infectious diseases that included Taenia saginata cysticercosis, bovine tuberculosis, Q-fever, bovine brucellosis, and bovine leptospirosis. Five enzyme-linked immunosorbent assays (ELISAs) were used to test for the presence of antibodies to the diseases, except Taenia saginata, for which we tested for the presence of Taenia metacestode circulating antigens. The overall highest prevalence was for T. saginata (46.4%), with lower prevalence for Q-fever (4%), leptospirosis (3%), tuberculosis (1%), and brucellosis (0.2%). Although there were no significant differences in the proportion of seroprevalence between sex and age of the animals sampled, there were significant differences between the provincial distributions. Further studies are required to determine the seroprevalence of these infections in other locations in Lao PDR, as well as other animal species including humans, in order to develop effective prevention and control strategies. This is the first study to investigate the prevalence of bovine zoonotic infectious agents in the Lao PDR. Positivity was demonstrated for all diseases investigated, with the highest prevalence for T. saginata antigen and Coxiella burnetti antibodies. For T. saginata, there were significant differences in the provincial distribution. Approximately 16% seroprevalence of Coxiella burnetti was noted in Xayabuly Province; however, there are no clear reasons why this was the case, and further studies are required to determine risk factors associated with this observation.
Wells, Scott J.; Collins, Michael T.; Faaberg, Kay S.; Wees, Carrie; Tavornpanich, Saraya; Petrini, Kristine R.; Collins, James E.; Cernicchiaro, Natalia; Whitlock, Robert H.
2006-01-01
A high-throughput TaqMan PCR assay for detection of bovine paratuberculosis was evaluated by using fecal samples from 1,808 dairy cattle in seven naturally infected herds and 347 dairy cattle in seven herds considered free of paratuberculosis. Fecal, blood, and milk samples were submitted to laboratories where the PCR-based assay, three different fecal culture procedures for Mycobacterium avium subsp. paratuberculosis (centrifugation, sedimentation, and the BACTEC filter concentration method), two serologic enzyme-linked immunosorbent assays (ELISAs), and one milk ELISA were performed. Results from testing of dairy cattle in herds free of M. avium subsp. paratuberculosis showed that the PCR assay's specificity was 99.7%. Twenty-three percent of the dairy cows that were fecal culture positive by at least one of the three methods were positive by the PCR assay. By Bayesian non-“gold standard” analysis methods, the TaqMan PCR assay had a higher specificity than the serum ELISAs (99.3%; 95% confidence interval [CI] = 98.6 to 99.7%) and a test sensitivity similar to that of the serum ELISAs (29%; 95% CI = 24 to 35%). By classical methods, the estimated relative sensitivity of the fecal PCR assay was 4% for light and moderate fecal shedders (compared to 12 to 13% for the ELISAs) and 76% for heavy fecal shedders (compared to 67% for the milk ELISA). The PCR assay has higher sensitivity for detection of heavy fecal shedders than the evaluated milk ELISA but lower sensitivity than a serum or milk ELISA for detection of light and moderate fecal shedders. This assay can be used as a quick test for detection of cattle with heavy fecal shedding, those cattle with the highest risk of transmitting infection to susceptible cattle. PMID:16928884
Serological detection systems for identification of cows shedding bovine foamy virus via milk.
Romen, Fabian; Backes, Perdita; Materniak, Magda; Sting, Reinhard; Vahlenkamp, Thomas W; Riebe, Roland; Pawlita, Michael; Kuzmak, Jacek; Löchelt, Martin
2007-07-20
The biology of foamy viruses, their mode of transmission and disease potential in their natural host and after interspecies transmission are largely unknown. To gain insights into the prevalence of bovine foamy virus (BFV) and its zoonotic potential, enzyme-linked immunosorbent assays (ELISAs) were established to determine antibody responses against Gag, Env, and the non-structural protein Bet in bovine serum and milk. In Polish cattle, strong Gag reactivity was most frequent (41.5%) and strongly associated with Bet antibodies, Env antibodies were less frequent. German cattle showed a low overall BFV antibody prevalence of 6.8%. Besides clearly BFV-positive animals, a substantial number of weakly reacting cattle were identified. BFV-specific antibodies were also detectable in milk. BFV was isolated from PBLs and milk cells of BFV-positive cattle but not from antibody-negative or weakly reacting animals. The implications of these findings for the potential interspecies transmission of BFV to humans will be discussed.
Czopowicz, Michał; Szaluś-Jordanow, Olga; Mickiewicz, Marcin; Moroz, Agata; Witkowski, Lucjan; Markowska-Daniel, Iwona; Bagnicka, Emilia; Kaba, Jarosław
2017-09-01
The study was conducted to evaluate influence of the true within-herd prevalence of small ruminant lentivirus (SRLV) infection on agreement beyond chance between three different types of commercial serological ELISAs. Blood samples were collected from 865 goats from 12 dairy goat herds. Serum samples were tested using three commercial ELISA kits: whole-virus indirect ELISA (wELISA), indirect ELISA based on recombined TM and CA antigens (TM/CA-ELISA), and competitive-inhibition ELISA based on SU antigen (SU-ELISA). Herds were classed into three prevalence strata of high (>50%), moderate (10-50%) and low (<10%) true within-herd prevalence of SRLV infection. The latter was estimated on the basis of results of wELISA adjusted by its sensitivity and specificity. Agreement beyond chance between the three ELISAs was assessed at two levels. First, the general agreement was determined using two coefficients corrected for chance-agreement: Cohen's kappa and Gwet's AC 1 . Then, agreement between tests was evaluated using Gwet's AC 1 separately in the three prevalence strata and compared between them by computing 95% confidence intervals for differences with a Bonferroni correction for multiple comparisons. The general agreement between the three tests was very good: wELISA and TM/CA-ELISA - Cohen's kappa of 81.8% (CI 95%: 77.9% to 85.7%), Gwet's AC 1 of 82.7% (CI 95%: 79.0% to 86.4%); wELISA and SU-ELISA - Cohen's kappa of 83.2% (CI 95%: 79.4% to 86.9%), Gwet's AC 1 of 83.9% (CI 95%: 80.4% to 87.5%); TM/CA-ELISA and SU-ELISA - Cohen's kappa of 86.0% (CI 95%: 82.6% to 89.5%), Gwet's AC 1 of 86.9% (CI 95%: 83.6% to 90.1%). However, agreement between ELISAs was significantly related to the within-herd true prevalence - it was significantly lower (although still high) when within-herd true prevalence was moderate (Gwet's AC 1 between 67.2% and 78.7%), whereas remained very high, when true within-herd prevalence was either >50% (Gwet's AC 1 between 91.9% and 98.8%) or <10% (Gwet's AC 1 between 94.7% and 98.4%). Concluding, the three different commercial ELISAs for SRLV infection in goats available on the market yield highly consistent results. However, their agreement is affected by the true within-herd prevalence in a tested population, and the worse (although still high) agreement should be expected, when the percentage of infected goats is moderate. Copyright © 2017 Elsevier B.V. All rights reserved.
Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina M
2012-05-02
Among the major food allergies, peanut, egg, and milk are the most common. The immunochemical detection of food allergens depends on various factors, such as the food matrix and processing method, which can affect allergen conformation and extractability. This study aimed to (1) develop matrix-specific incurred reference materials for allergen testing, (2) determine whether multiple allergens in the same model food can be simultaneously detected, and (3) establish the effect of processing on reference material stability and allergen detection. Defatted peanut flour, whole egg powder, and spray-dried milk were added to cookie dough at seven incurred levels before baking. Allergens were measured using five commercial enzyme-linked immunosorbent assay (ELISA) kits. All kits showed decreased recovery of all allergens after baking. Analytical coefficients of variation for most kits increased with baking time, but decreased with incurred allergen level. Thus, food processing negatively affects the recovery and variability of peanut, egg, and milk detection in a sugar cookie matrix when using immunochemical methods.
Sandwich enzyme-linked immunosorbent assay for naringin.
Qu, Huihua; Wang, Xueqian; Qu, Baoping; Kong, Hui; Zhang, Yue; Shan, Wenchao; Cheng, Jinjun; Wang, Qingguo; Zhao, Yan
2016-01-15
Among the currently used immunoassay techniques, sandwich ELISA exhibits higher specificity, lower cross-reactivity, and a wider working range compared to the corresponding competitive assays. However, it is difficult to obtain a pair of antibodies that can simultaneously bind to two epitopes of a molecule with a molecular weight of less than 1000 Da. Naringin (Nar) is a flavonoid with a molecular mass of 580 Da. The main aim of this study was to develop a sandwich ELISA for detecting Nar. Two hybridomas secreting anti-Nar monoclonal antibodies (mAbs) were produced by fusing splenocytes from a mouse immunised against Nar-bovine serum albumin (BSA) conjugated with a hypoxanthine-aminopterin-thymidine (HAT)-sensitive mouse myeloma cell line; a sandwich ELISA for detecting Nar was developed using these two well-characterised anti-Nar mAbs. The performance of the sandwich assay was further evaluated by limit of detection (LOD), limit of quantification (LOQ), recovery, and interference analyses. A dose-response curve to Nar was obtained with an LOD of 6.78 ng mL(-1) and an LOQ of 13.47 ng mL(-1). The inter-assay and intra-assay coefficients of variation were 4.32% and 7.48%, respectively. The recovery rate of Nar from concentrated Fructus aurantii granules was 83.63%. A high correlation was obtained between HPLC and sandwich ELISA. These results demonstrate that the sandwich ELISA method has higher specificity for Nar than indirect competitive ELISA. Copyright © 2015 Elsevier B.V. All rights reserved.
Panda, Rakhi; Boyer, Marc; Garber, Eric A E
2017-12-01
A novel competitive ELISA was developed utilizing the G12, R5, 2D4, MIoBS, and Skerritt antibody-HRP conjugates employed in nine commercial ELISA test kits that are routinely used for gluten detection. This novel multiplex competitive ELISA simultaneously measures gliadin-, deamidated gliadin-, and glutenin-specific epitopes. The assay was used to evaluate 20 wheat beers, 20 barley beers, 6 barley beers processed to reduce gluten, 15 soy sauces, 6 teriyaki sauces, 6 Worcestershire sauces, 6 vinegars, and 8 sourdough breads. For wheat beers, the apparent gluten concentration values obtained by the G12 and Skerritt antibodies were typically higher than those obtained using the R5 antibodies. The sourdough bread samples resulted in higher apparent gluten concentration values with the Skerritt antibody, while the values generated by the G12 and R5 antibodies were comparable. Although the soy-based sauces showed non-specific inhibition with the multiple R5 and G12 antibodies, their overall profile was distinguishable from the other categories of fermented foods. Cluster analysis of the apparent gluten concentration values obtained by the multiplex competitive ELISA, as well as the relative response of the nine gluten-specific antibodies used in the assay to different gluten proteins/peptides, distinguishes among the different categories of fermented-hydrolyzed foods by recognizing the differences in the protein/peptide profiles characteristic of each product. This novel gluten-based multiplex competitive ELISA provides insight into the extent of proteolysis resulting from various fermentation processes, which is essential for accurate gluten quantification in fermented-hydrolyzed foods. Graphical abstract A novel multiplex competitive ELISA for the detection and characterization of gluten in fermented-hydrolyzed foods.
Liang, Cheng-Zhu; Cao, Rui-Bing; Wei, Jian-Chao; Zhu, Lai-Hua; Chen, Pu-Yan
2006-06-01
According to the antigenic analysis of equine arteritis virus (EAV) GL protein, one pair of primers were designed, with which the gene fragment coding the high antigenic domain of EAV GL protein was amplified from the EAV genome. The cloned gene was digested with BamH I and Xho I and then inserted into pET-32a and resulted pET-GL1. The pET-GL1 was transformed into the host cell BL21(DE3) and the expression was optimized including cultivation temperature and concentration of IPTG. The aim protein was highly expressed and the obtained recombinant protein manifested well reactiongenicity as was confirmed by Western blot. The recombinant GL1 protein was purified by the means of His * Bind resin protein purification procedure. Then an indirect ELISA was established to detect antibody against EAV with the purified GL1 protein as the coating antigen. The result showed that the optimal concentration of coated antigen was 9.65 microg/mL and the optimal dilution of serum was 1:80. The positive criterion of this ELISA assay is OD (the tested serum) > 0.4 and OD (the tested serum) /OD (the negative serum) > 2.0. The iGL-ELISA was evaluated versus micro-virus neutralization test. The ELISA was performed on 900 sera from which were preserved by this lab during horse entry/exit inspection, the agreement (94.1%) of these test were considered suitable for individual serological detection. In another test which 180 sera samples were detected by iGL-ELISA and INGEZIM ELISA kit respectively. The agreement ratio between the two methods is 95.6%.
de Almeida Carlos, Lanamar; da Silva Amaral, Kenas Aguiar; Curcino Vieira, Ivo José; Mathias, Leda; Braz-Filho, Raimundo; Silva Samarão, Solange; Vieira-da-Motta, Olney
2010-01-01
Staphylococci bacteria are involved in many human and animal infections and development of alternative antimicrobial drugs against pathogenic bacteria is of great interest to the pharmaceutical industry. This study investigated the in vitro effect of Rauvolfia grandiflora methanol extract (root bark fraction) (RGE) on the density of ATCC strains of Staphylococcus aureus and Staphylococcus epidermidis, and a clinical enterotoxin-producer, S. aureus bovine strain. The alkaloid, isoreserpiline, obtained from dichloromethane extract of R. grandiflora was ineffective against the strains tested. After incubation of staphylococci strains in the presence of 1.2 μg.mL-1 RGE, a significant inhibition of cell growth was observed using both spectrophotometry and ELISA assays. Twelve drugs were evaluated for their antimicrobial effects on culture RGE-treated cells using the disk diffusion method. Penicillin resistant strains became sensitive to the drug after RGE treatment. Furthermore, enterotoxin production by RGE-treated S. aureus was evaluated using a standardized ELISA method. Although staphylococcal LSA 88 bovine strain cells remained viable after exposure to the extract, enterotoxin production was precluded in 20% after RGE treatment. Significant interference in staphylococci cell density, drug sensitivity and enterotoxin secretion was observed after treatment. The study highlights the necessity to find new methods of disease prevention and new antibiotic therapies against staphylococcal infections. PMID:24031536
de Almeida Carlos, Lanamar; da Silva Amaral, Kenas Aguiar; Curcino Vieira, Ivo José; Mathias, Leda; Braz-Filho, Raimundo; Silva Samarão, Solange; Vieira-da-Motta, Olney
2010-07-01
Staphylococci bacteria are involved in many human and animal infections and development of alternative antimicrobial drugs against pathogenic bacteria is of great interest to the pharmaceutical industry. This study investigated the in vitro effect of Rauvolfia grandiflora methanol extract (root bark fraction) (RGE) on the density of ATCC strains of Staphylococcus aureus and Staphylococcus epidermidis, and a clinical enterotoxin-producer, S. aureus bovine strain. The alkaloid, isoreserpiline, obtained from dichloromethane extract of R. grandiflora was ineffective against the strains tested. After incubation of staphylococci strains in the presence of 1.2 μg.mL(-1) RGE, a significant inhibition of cell growth was observed using both spectrophotometry and ELISA assays. Twelve drugs were evaluated for their antimicrobial effects on culture RGE-treated cells using the disk diffusion method. Penicillin resistant strains became sensitive to the drug after RGE treatment. Furthermore, enterotoxin production by RGE-treated S. aureus was evaluated using a standardized ELISA method. Although staphylococcal LSA 88 bovine strain cells remained viable after exposure to the extract, enterotoxin production was precluded in 20% after RGE treatment. Significant interference in staphylococci cell density, drug sensitivity and enterotoxin secretion was observed after treatment. The study highlights the necessity to find new methods of disease prevention and new antibiotic therapies against staphylococcal infections.
Ilha, Marcia R S; Coarsey, Michele; Whittington, Lisa; Rajeev, Sreekumari; Ramamoorthy, Sheela
2012-11-01
The prevalence of Bovine viral diarrhea virus (BVDV) in free-ranging white-tailed deer (WTD, Odocoileus virginianus) in the state of Georgia was evaluated using ear notches collected from hunter-harvested deer during the hunting season of 2010-2011. From September to December 2010, 367 ear samples from WTD were collected from 37 counties in Georgia. The samples were from 178 (48.5%) female deer, 187 (51%) male deer, and 2 (0.5%) of unknown sex. The age of the animals varied from 6 months to 6.5 years. The age was not recorded in 34 animals (9.3%). Of the animals with known ages, 42% were under 2 years. Screening of 367 samples for BVDV using an antigen-capture enzyme-linked immunosorbent assay (AgELISA) resulted in 364 negative samples and 3 suspect samples. The 3 suspect samples were negative for BVDV reverse transcription polymerase chain reaction (RT-PCR), virus isolation, and immunohistochemistry. A subpopulation of samples (n = 89) selected from various geographical regions also tested negative for BVDV RT-PCR. In conclusion, although a few of the samples were suspect for the presence of BVDV by AgELISA, the presence of the virus within the deer population studied could not be confirmed further.
Aldisi, Rana S; Elsidiq, Malaz S; Dargham, Soha R; Sahara, Afifah S; Al-Absi, Enas S; Nofal, Mariam Y; Mohammed, Layla I; Abu-Raddad, Laith J; Nasrallah, Gheyath K
2018-03-22
The number of diagnostic assays for the detection of herpes simplex virus type 1 (HSV-1) antibodies has increased over the years. However, their performance characteristics could vary among global populations. To investigate performance of two commercial ELISA kits, HerpeSelect ® 1 ELISA and Euroimmun Anti-HSV-1 (gC1) ELISA (IgG); and two commercial immunoblot (IB)/Western blot (WB) assays, HerpeSelect ® 1 and 2 Immunoblot IgG, and Euroimmun Anti-HSV-1/HSV-2 gG2 Euroline-WB (IgG/IgM); in detecting HSV-1 antibodies in a Middle East and North Africa (MENA) population. Blood specimens were collected from blood donors in Doha, Qatar, June 2013-2016. Twenty specimens were randomly selected from 10 MENA nationalities (Egypt, Iran, Jordan, Lebanon, Pakistan, Palestine, Qatar, Sudan, Syria, and Yemen; total = 200), and tested for HSV-1 antibodies. Across all six comparisons between assays, positive percent agreement ranged between 95.7% (95% CI: 91.4-98.3%) and 100.0% (95% CI: 97.8-100.0%). Negative percent agreement ranged between 86.2% (95% CI: 68.3-96.1%) and 96.2% (95% CI: 80.4-99.9%). Overall percent agreement ranged between 95.7% (95% CI: 91.7-97.8%) and 99.4% (95% CI: 96.7-99.9%). Cohen's kappa statistic ranged between 0.84 (95% CI: 0.73-0.95) and 0.98 (95% CI: 0.93-1.00). Compared against IB/WB, HerpeSelect ® and Euroimmun had sensitivities and specificities >96% and >86%, respectively. Positive and negative predictive values were >97% and >83%, respectively. The assays showed excellent concordance with one another, and with a high kappa statistic. The ELISA kits demonstrated robust diagnostic performance compared to the IB/WB assays. These findings support the assays' utility in clinical diagnosis and research in MENA populations. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Bauermann, Fernando V; Flores, Eduardo F; Falkenberg, Shollie M; Weiblen, Rudi; Ridpath, Julia F
2014-01-01
The detection of an emerging pestivirus species, "HoBi-like virus," in fetal bovine serum (FBS) labeled as U.S. origin, but packaged in Europe, raised concerns that HoBi-like virus may have entered the United States. In the current study, 90 lots of FBS originating in North America (NA) were screened for pestivirus antigen and antibodies. Lots in group 1 (G1, 72 samples) and group 2 (G2, 9 samples) originated in NA and were packaged in the United States. Group 3 (G3) was composed of 9 lots collected in NA and processed in Europe. Lots in G1 were claimed negative for Bovine viral diarrhea virus (BVDV), while lots in G2 and G3 were claimed positive by the commercial processor. All lots in G1 and G2 tested negative by reverse transcription polymerase chain reaction (RT-PCR) using HoBi-like-specific primers. Two G1 lots tested positive by BVDV RT-PCR. One of these was also positive by virus isolation. All G2 lots were positive by BVDV RT-PCR. In addition, four G2 lots were VI positive while 1 lot was antigen-capture enzyme-linked immunosorbent assay (ELISA) positive. Two G3 lots were positive by HoBi-like-specific RT-PCR tests. All lots were negative for HoBi_D32/00 neutralizing antibodies. Seven lots (4 G1; 1 G2; 2 G3) had antibodies against BVDV by virus neutralization and/or antigen-capture ELISA. While there is no evidence of HoBi-like viruses in NA based on tested samples, further studies are required to validate HoBi-like virus-free status and develop means to prevent the spread of HoBi-like virus into NA.
Otto, Peter H.; Clarke, Ian N.; Lambden, Paul R.; Salim, Omar; Reetz, Jochen; Liebler-Tenorio, Elisabeth M.
2011-01-01
The experimental infection of newborn calves with bovine norovirus was used as a homologous large animal model to study the pathogenesis of norovirus infection and to determine target cells for viral replication. Six newborn calves were inoculated orally with Jena virus (JV), a bovine norovirus GIII.1 strain, and six calves served as mock-inoculated controls. Following infection, calves were euthanized before the onset of diarrhea (12 h postinoculation [hpi]), shortly after the onset of diarrhea (18 to 21 hpi), and postconvalescence (4 days pi [dpi]). Calves inoculated with JV developed severe watery diarrhea at 14 to 16 hpi, and this symptom lasted for 53.5 to 67.0 h. Intestinal lesions were characterized by severe villus atrophy together with loss and attenuation of villus epithelium. Viral capsid antigen (JV antigen) was detected by immunohistochemistry in the cytoplasm of epithelial cells on villi. In addition, granular material positive for JV antigen was detected in the lamina propria of villi. Lesions first appeared at 12 hpi and were most extensive at 18 to 19 hpi, extending from midjejunum to ileum. The intestinal mucosa had completely recovered at 4 dpi. There was no indication of systemic infection as described for norovirus infection in mice. JV was found in intestinal contents by reverse transcription-PCR (RT-PCR) and enzyme-linked immunosorbent assay (ELISA) as early as 12 hpi. Fecal shedding of the virus started at 13 hpi and stopped at 23 hpi or at necropsy (4 dpi), respectively. Throughout the trial, none of the control calves tested positive for JV by ELISA or RT-PCR. PMID:21880760
Emmerzaal, A; de Wit, J J; Dijkstra, Th; Bakker, D; van Zijderveld, F G
2002-02-01
The Dutch national Brucella abortus eradication programme for cattle started in 1959. Sporadic cases occurred yearly until 1995; the last infected herd was culled in 1996. In August 1999 the Netherlands was declared officially free of bovine brucellosis by the European Union. Before 1999, the programme to monitor the official Brucella-free status of bovine herds was primarily based on periodical testing of dairy herds with the milk ring test (MRT) and serological testing of all animals older than 1 year of age from non-dairy herds, using the micro-agglutination test (MAT) as screening test. In addition, serum samples of cattle that aborted were tested with the MAT. The high number of false positive reactions in both tests and the serum agglutination test (SAT) and complement fixation test (CFT) used for confirmation seemed to result in unnecessary blockade of herds, subsequent testing and slaughter of animals. For this reason, a validation study was performed in which three indirect enzyme-linked immunosorbent assays (ELISAs), the CFT and the SAT were compared using a panel of sera from brucellosis-free cattle, sera from experimentally infected cattle, and sera from cattle experimentally infected with bacteria which are known to induce cross-reactive antibodies (Pasteurella, Salmonella, Yersinia, and Escherichia). Moreover, four ELISAs and the MRT were compared using a panel of 1000 bulk milk samples from Brucella-free herds and 12 milk samples from Brucella abortus- infected cattle. It is concluded that the ELISA obtained from ID-Lelystad is the most suitable test to monitor the brucelosis free status of herds because it gives rise to fewer false-positive reactions than the SAT.
Discovery and Validation of Proteomic Biomarkers for Radiation Exposure
2012-02-01
1: CDKN IA protein levels as a function radiation dosage, as measured by K. Wilson at Stanford using ELISA kits. We have developed magneto -nano...8217<: ~ 100 0 I o j ! Figu re 3: Sensitivity and dynamic range of CDKNJA radiation marker in magneto -nano sensor and ELTSA, l respectively...Interactions/Transitions Shan Wang gave the following inv ited talks in major meetings: l . S. X. Wang, " Magneto -Nano Protein Chip and Multiplex Sorter
Niitsu, Tomihisa; Ishima, Tamaki; Yoshida, Taisuke; Hashimoto, Tasuku; Matsuzawa, Daisuke; Shirayama, Yukihiko; Nakazato, Michiko; Shimizu, Eiji; Hashimoto, Kenji; Iyo, Masaomi
2014-02-28
A meta-analysis study reported serum brain-derived neurotrophic factor (BDNF) levels as a potential biomarker for schizophrenia. However, at the time, commercially available human ELISA kits were unable to distinguish between pro-BDNF (precursor BDNF) and mature BDNF, because of limited antibody specificity. Here, we used new ELISA kits, to examine serum levels of mature BDNF and matrix metalloproteinase-9 (MMP-9), which converts pro-BDNF to mature BDNF in schizophrenia. Sixty-three patients with chronic schizophrenia and 52 age- and sex-matched healthy controls were enrolled. Patients were evaluated using the Brief Psychiatry Rating Scale, the Scale for the Assessment of Negative Symptoms (SANS) and neuropsychological tests. Neither serum mature BDNF nor MMP-9 levels differed between patients and controls. In male subgroups, serum MMP-9 levels of smoking patients were higher than those of non-smoking patients, but this was not observed in male controls or the female subgroup. In patients, serum mature BDNF levels were associated with SANS total scores and the Information subtest scores of the Wechsler Adult Intelligence Scale Revised (WAIS-R), while serum MMP-9 levels were associated with smoking and category fluency scores. These findings suggest that neither mature BDNF nor MMP-9 is a suitable biomarker for schizophrenia, although further studies using large samples are needed. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Schmitz, Audrey; Le Bras, Marie-Odile; Guillemoto, Carole; Pierre, Isabelle; Rose, Nicolas; Bougeard, Stéphanie; Jestin, Véronique
2013-10-01
Following the emergence of highly pathogenic avian influenza (AI), active surveillance of infections due to the H5 and H7 subtypes in poultry has increased and been made compulsory in Europe since 2002, by means of annual serological surveys using the haemagglutination inhibition (HI) test. Domestic anseriforms, particularly ducks and geese, are more frequently infected by H5 low pathogenic AI virus, often subclinically, and represent a threat for other terrestrial poultry. 1783 sera, mainly from ducks, have been used to evaluate and compare a commercial ELISA kit detecting H5 antibodies with the currently recommended HI test. Different approaches to calculating specificity and sensitivity have been used, including the original Bayesian method. Results were similar when data were analyzed at the individual and batch levels, and when using different methods of calculation. However, results showed that H5 ELISA had both a higher sensitivity and a lower specificity than the HI test. Given that sensitivity is the most important factor for a screening test, H5 ELISA could therefore be recommended for AI surveillance, followed in cases of positivity by molecular tests aimed at detecting the virus gene. Copyright © 2013 Elsevier B.V. All rights reserved.
Bernitz, Netanya; Clarke, Charlene; Roos, Eduard O; Goosen, Wynand J; Cooper, David; van Helden, Paul D; Parsons, Sven D C; Miller, Michele A
2018-02-01
African buffaloes (Syncerus caffer) are wildlife maintenance hosts of Mycobacterium bovis, the cause of bovine tuberculosis. Consequently, M. bovis infected buffaloes pose a transmission risk for cattle and other wildlife species. Previously, a modification to the Qiagen QuantiFERON ® -TB Gold (QFT) system, using QFT tubes and an in-house bovine interferon-gamma (IFN-γ) ELISA, was evaluated for the detection of M. bovis infection in buffaloes. Subsequently, Qiagen has developed a commercially available cattletype ® IFN-gamma ELISA for the detection of antigen-specific IFN-γ release in ruminants. The aim of this study was to investigate the use of QFT tubes and the cattletype ® IFN-gamma ELISA, in a cattletype IFN-γ release assay (IGRA), to detect M. bovis infection in African buffaloes. The test agreements between the cattletype IGRA, single comparative intradermal skin test (SCITT) and Bovigam ® 1G IGRA in two M. bovis-exposed buffalo populations (n = 134 and n = 92) were calculated and κ coefficients ranged from 0.65 (95% CI 0.48-0.82) to 0.86 (95% CI 0.72-0.99). Increasing the QFT incubation time in one M. bovis-exposed buffalo cohort (n = 92), from 20 to 40 h, had no effect on the cattletype IGRA test results. Inter-assay and intra-assay reproducibility determination for the cattletype IGRA produced coefficient of variations (CV) <9.1% and <1.7%, respectively. A total of 21/21 known M. bovis-unexposed buffaloes tested negative in the cattletype IGRA. Moreover, the cattletype IGRA test result values were significantly greater for 13 M. bovis culture-positive buffaloes compared with 14 M. bovis-exposed culture-negative (P < .01) and 21 M. bovis-unexposed (P < .001) buffaloes, respectively. These findings suggest that the combination of QFT tubes and the cattletype ® IFN-gamma ELISA is a promising new diagnostic assay for the detection of M. bovis infection in African buffaloes. However, further research is needed to evaluate the sensitivity and specificity of the assay in larger African buffalo populations. Copyright © 2017 Elsevier B.V. All rights reserved.
Cho, Ki-hyun; Kim, Jeongmi; Yoo, Hyun-ah; Kim, Dae-hee; Park, Seung-yong; Song, Chang-seon; Choi, In-soo; Lee, Joong-bok
2014-12-01
Simple methods for measuring the levels of serum antibody against canine distemper virus (CDV) would assist in the effective vaccination of dogs. To develop an enzyme-linked immunosorbent assay (ELISA) specific for CDV, we expressed hydrophilic extra-viral domain (HEVD) protein of the A75/17-CDV H gene in a pET 28a plasmid-based Escherichia (E.) coli vector system. Expression was confirmed by dot and Western blotting. We proposed that detection of E. coli-expressed H protein might be conformation- dependent because intensities of the reactions observed with these two methods varied. The H gene HEVD protein was further purified and used as an antigen for an ELISA. Samples from dogs with undetectable to high anti-CDV antibody titers were analyzed using this HEVD-specific ELISA and a commercial CDV antibody detection kit (ImmunoComb). Levels of HEVD antigenicity measured with the assays and immunochromatography correlated. These data indicated that the HEDV protein may be used as antigen to develop techniques for detecting antibodies against CDV.
He, Jing; Xiu, Bingshui; Wang, Guohua; Chen, Kun; Feng, Xiaoyan; Song, Xiaoguo; Zhu, Cuixia; Yang, Xiqin; Bai, Guanzhong; Ling, Shigan; Zhang, Heqiu
2011-08-01
Based on B cell epitope predictions, a recombinant antigen with multiple epitopes from four Hepatitis C Virus fragments (C, NS3, NS4 and NS5) were engineered. The recombinant gene was then highly expressed in E. coli. The non-modified and C-terminal-modified recombinant proteins were used for coating and biotin labeling, respectively, to establish the double-antigen sandwich ELISA. Ten positive reference samples confirmed by the CHIRON RIBA HCV 3.0 SIA kit were detected positive, Forty one plasma samples were positive among samples from 441 volunteers, which indicated that the recombinant antigen could readily react well with plasma HCV antibody. As critical reagents of double-antigen sandwich ELISA, the recombinant multi-epitope antigen and the C-terminal-modified and biotin-conjugated antigen show good antigenicity. In this study, we provide a simple approach to produce multiple epitopes within one recombinant protein in order to avoid the costly expression of less-effective pools of multiple proteins, which is the conventional strategy of diagnostic antigen production for HCV antibody detection.
Scherf, Katharina Anne; Wieser, Herbert; Koehler, Peter
2016-10-12
Purified wheat starch (WSt) is commonly used in gluten-free products for celiac disease (CD) patients. It is mostly well-tolerated, but doubts about its safety for CD patients persist. One reason may be that most ELISA kits primarily recognize the alcohol-soluble gliadin fraction of gluten, but insufficiently target the alcohol-insoluble glutenin fraction. To address this problem, a new sensitive method based on the sequential extraction of gliadins, glutenins, and gluten from WSt followed by gel-permeation high-performance liquid chromatography with fluorescence detection (GP-HPLC-FLD) was developed. It revealed that considerable amounts of glutenins were present in most WSt. The gluten contents quantitated by GP-HPLC-FLD as sum of gliadins and glutenins were higher than those by R5 ELISA (gluten as gliadin content multiplied by a factor of 2) in 19 out of 26 WSt. Despite its limited selectivity, GP-HPLC-FLD may be applied as confirmatory method to ELISA to quantitate gluten in WSt.
Su, Kuo-Hui; Tsai, Jin-Yi; Kou, Yu Ru; Chiang, An-Na; Hsiao, Sheng-Huang; Wu, Yuh-Lin; Hou, Hsin-Han; Pan, Ching-Chian; Shyue, Song-Kun; Lee, Tzong-Shyuan
2009-06-01
Valsartan, a selective angiotensin II type 1 receptor (AT1R) blocker, has beneficial effects in the cardiovascular system in part by its increase of nitric oxide (NO) bioavailability, yet the mechanisms are unclear. We investigated the molecular mechanisms underlying this effect in endothelial cells (ECs). NO production was examined by Griess reagent assay, DAF-2 DA fluorescence staining and cGMP ELISA kits. Protein interaction was determined by western blotting and immunoprecipitation. Treating bovine or human aortic ECs with valsartan increased NO production, as evidenced by elevated level of stable NO metabolites and intracellular cGMP. Valsartan increased the phosphorylation but not the protein level of endothelial NO synthase (eNOS). Inhibition of phosphoinositide-3 kinase (PI3K)/Akt and Src pathways by specific inhibitors suppressed valsartan-induced NO release. In addition, valsartan increased the tyrosine residue phosphorylation of AT1R, which was attenuated by inhibition of Src but not PI3K activities. Valsartan also suppressed the interaction of eNOS and AT1R, which was blocked by Src or PI3K inhibition. Valsartan-induced NO production in ECs is mediated through Src/PI3K/Akt-dependent phosphorylation of eNOS. Valsartan-induced AT1R phosphorylation depends on Src but not PI3K, whereas valsartan-induced suppression of AT1R-eNOS interaction depends on Src/PI3K/Akt signalling. These results indicate a novel vasoprotective mechanism of valsartan in upregulating NO production in ECs.
Frelinger, A L; Torres, A S; Caiafa, A; Morton, C A; Berny-Lang, M A; Gerrits, A J; Carmichael, S L; Neculaes, V B; Michelson, A D
2016-01-01
Therapeutic use of activated platelet-rich plasma (PRP) has been explored for wound healing, hemostasis and antimicrobial wound applications. Pulse electric field (PEF) stimulation may provide more consistent platelet activation and avoid complications associated with the addition of bovine thrombin, the current state of the art ex vivo activator of therapeutic PRP. The aim of this study was to compare the ability of PEF, bovine thrombin and thrombin receptor activating peptide (TRAP) to activate human PRP, release growth factors and induce cell proliferation in vitro. Human PRP was prepared in the Harvest SmartPreP2 System and treated with vehicle, PEF, bovine thrombin, TRAP or Triton X-100. Platelet activation and procoagulant markers and microparticle generation were measured by flow cytometry. Released growth factors were measured by ELISA. The releasates were tested for their ability to stimulate proliferation of human epithelial cells in culture. PEF produced more platelet-derived microparticles, P-selectin-positive particles and procoagulant annexin V-positive particles than bovine thrombin or TRAP. These differences were associated with higher levels of released epidermal growth factor after PEF than after bovine thrombin or TRAP but similar levels of platelet-derived, vascular-endothelial, and basic fibroblast growth factors, and platelet factor 4. Supernatant from PEF-treated platelets significantly increased cell proliferation compared to plasma. In conclusion, PEF treatment of fresh PRP results in generation of microparticles, exposure of prothrombotic platelet surfaces, differential release of growth factors compared to bovine thrombin and TRAP and significant cell proliferation. These results, together with PEF's inherent advantages, suggest that PEF may be a superior alternative to bovine thrombin activation of PRP for therapeutic applications.
IgE antibody to fish gelatin (type I collagen) in patients with fish allergy.
Sakaguchi, M; Toda, M; Ebihara, T; Irie, S; Hori, H; Imai, A; Yanagida, M; Miyazawa, H; Ohsuna, H; Ikezawa, Z; Inouye, S
2000-09-01
Most children with anaphylaxis to measles, mumps, and rubella vaccines had shown sensitivity to bovine gelatin that was included in the vaccines. Recently, it was found that bovine type I collagen, which is the main content in the gelatin, is a major allergen in bovine gelatin allergy. Fish meat and skin also contain type I collagen. The present study was designed to investigate IgE antibody to fish gelatin in children with fish allergy. Serum samples were taken from patients in 3 groups: (1) 10 patients with fish allergy and specific IgE to fish meat; (2) two patients with allergies to both fish meat and bovine gelatin and specific IgE to fish meat and bovine gelatin; and (3) 15 patients with atopic dermatitis and specific IgE to fish meat. Various fish gelatins (type I collagen) were prepared from fish skin. IgE antibody to fish gelatin was analyzed by using ELISA and immunoblotting. Of 10 patients with fish allergy, 3 had specific IgE to fish gelatin. Of two patients with fish allergy and bovine gelatin allergy, all had specific IgE to fish gelatin. Of 15 patients with atopic dermatitis and specific IgE to fish meat, 5 had specific IgE to fish gelatin. Furthermore, IgE from pooled serum of the patients reacted with both the alpha1 and alpha2 chains of fish type I collagen in immunoblots. There is cross-reactivity among gelatins from various fishes, but there is little cross-reactivity between fish and bovine gelatins. Some fish-sensitive patients possessed IgE antibody to fish gelatin. Fish gelatin (type I collagen) might be an allergen in subjects with fish allergy.
de Azevedo, Priscila Zacarias; Sylvestre, Tatiane Fernanda; Cavalcante, Ricardo de Souza; de Carvalho, Lídia Raquel; Moris, Daniela Vanessa; de Oliveira, Maria Luiza Cotrim Sartor; Mendes, Rinaldo Poncio
2015-01-01
The diagnosis of chronic pulmonary aspergillosis (CPA) depends on the radiologic image and the identification of specific antibodies. The present study aimed to evaluate accuracy parameters of enzyme-linked immunosorbent assay (ELISA) and of the determination of serum galactomannan level in the diagnosis of patients with CPA, comparing these results with the double agar gel immunodiffusion (DID) test. In addition, the prevalence of cross-reactivity and the serological progression after treatment were evaluated by comparing DID and ELISA. Six study groups were formed: G1: 22 patients with CPA, 17 of whom had Aspergillus fungus ball, one chronic cavitary pulmonary aspergillosis (CCPA) and four chronic fibrosing pulmonary aspergillosis (CFPA); G2: 28 patients with pulmonary tuberculosis (TB); G3: 23 patients with histoplasmosis (HST); G4: 50 patients with paracoccidioidomycosis (PCM); G5: 20 patients with cryptococcosis (CRC); and G6: 200 healthy controls. Serum antibodies were measured by DID and ELISA, with two antigen preparations—Aspergillus fumigatus (DID1, ELISA1) and a pool of A. fumigatus, A. flavus and A. niger antigens (DID2, ELISA2). The Platélia Aspergillus Enzyme Immunoassay (EIA) kit was used to measure galactomannan. The cut-off points of ELISA were determined for each antigen preparation and for the 95% and 99% confidence intervals. Despite the low sensitivity, DID was the technique of choice due to its specificity, positive and negative predictive values and positive likelihood ratio–especially with the antigen pool and due to the low frequency of cross-reactivity. ELISA1 and a 0.090 cut-off showed high sensitivity, specificity and negative predictive value, but a high frequency of cross-reactivity with CRC. The best degree of agreement was observed between ELISA1 and ELISA2. The detection of serum galactomannan showed high sensitivity, comparable to ELISA2. The immunodiffusion test showed an excellent relationship with the progression after treatment, which made it the reaction of choice for patient follow-up. PMID:26271000
Ultra-Sensitive Detection of Prion Protein in Blood Using Isothermal Amplification Technology
2005-12-01
cattle products are admitted into the food chain, the Western Blot or ELISA in an antigen detection format are used to test the bovine brain stems...the most sensitive fluorescent dye (SYBR Green I, SYBR Green II, or SYBR Gold) detection of transcription products using real-time technology...RNA products from ug quantities of DNA template. Figure 3 shows that SYBR Green II exhibited higher relative fluorescence units (RFU) than SYBR
2004 National Atrazine Occurrence Monitoring Program using the Abraxis ELISA method.
Graziano, Nicole; McGuire, Michael J; Roberson, Alan; Adams, Craig; Jiang, Hua; Blute, Nicole
2006-02-15
The goal of this project was to gain a better understanding of atrazine occurrence in the United States by surveying drinking water utilities' sources and finished water for atrazine on a weekly basis for seven months. Atrazine is a contaminant of interest because the United States Environmental Protection Agency (USEPA) has found short-term atrazine exposure above the drinking water maximum contaminant level (MCL) to potentially cause heart, lung, and kidney congestion, low blood pressure, muscle spasms, weight loss, and damage to the adrenal glands. Long-term exposure to atrazine concentrations above the drinking water MCL has been linked to weight loss, cardiovascular damage, retinal and muscle degeneration, and cancer. This survey effort improved upon previously conducted atrazine surveys through intensive, high frequency sampling (participating plants sampled their raw and finished water on a weekly basis for approximately seven months). Such an intensive effort allowed the authors to gain a better understanding of short-term atrazine occurrence and its variability in drinking water sources. This information can benefit the drinking water industry by facilitating (1) better atrazine occurrence management (i.e., awareness when plants may be more susceptible to atrazine), (2) more efficient atrazine control (e.g., effective treatment alternatives and more effective response to atrazine occurrence), and (3) treatment cost reduction (e.g., efficient atrazine control can result in substantial cost savings). Forty-seven drinking watertreatment plants located primarily in the Midwestern United States participated in the survey and sampled their raw and finished water on a weekly basis from March through October. Samples were analyzed using the Abraxis enzyme-linked immunosorbent assay (ELISA) test kit. Confirmation samples for quality assurance/quality control (QA/QC) purposes were analyzed using solid-phase extraction (SPE) followed by gas chromatography mass spectrophotometry (GC/MS). Several important conclusions can be drawn from this study including (1) surface waters were confirmed to be more vulnerable to atrazine contamination than groundwater sources, (2) peak atrazine concentrations corresponded well to precipitation/runoff events, and (3) atrazine occurrence tended to be uniform geographically when compared by river drainage basins. In addition, this project confirmed that the Abraxis atrazine ELISA test kit tended to have a positive bias (i.e., the measured ELISA concentration was higher than the actual concentration) in most measured samples. Finished samples tended to have more of a positive bias than raw water samples. Therefore, this bias may limit the effectiveness for ELISA for regulatory monitoring. There are many other applications for ELISA, however, including frequent monitoring for early detections of atrazine concentration changes that might trigger conventional analysis by GC/MS or be used for activated carbon dosing or other treatment operating controls.
2011-09-07
diarrhea and was subsequently hospitalized. Cryptosporidium parvum and Giardia lamblia were also found in the fecal matter of the patient; therefore, the... bovine serum (FBS), penicillin (200 U/ml), L-glutamine (2 mM), Fungizone (1 mg/ml), and streptomycin (200 mg/ml). HAdV-D58 was investigated serologi... particles were separated from Hep-2 cells by ultracentrifugation. Genomic DNA was acquired from viral particles using AccuPrep Genomic DNA Extraction Kit
A bacterial engineered glycoprotein as a novel antigen for diagnosis of bovine brucellosis.
Ciocchini, Andrés E; Serantes, Diego A Rey; Melli, Luciano J; Guidolin, Leticia S; Iwashkiw, Jeremy A; Elena, Sebastián; Franco, Cristina; Nicola, Ana M; Feldman, Mario F; Comerci, Diego J; Ugalde, Juan E
2014-08-27
Brucellosis is a highly contagious zoonosis that affects livestock and human beings. Laboratory diagnosis of bovine brucellosis mainly relies on serological diagnosis using serum and/or milk samples. Although there are several serological tests with different diagnostic performance and capacity to differentiate vaccinated from infected animals, there is still no standardized reference antigen for the disease. Here we validate the first recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of bovine brucellosis. This antigen can be produced in homogeneous batches without the need of culturing pathogenic brucellae; all characteristics that make it appropriate for standardization. An indirect immunoassay based on the detection of anti O-polysaccharide IgG antibodies in bovine samples was developed coupling OAg-AcrA to magnetic beads or ELISA plates. As a proof of concept and to validate the antigen, we analyzed serum, whole blood and milk samples obtained from non-infected, experimentally infected and vaccinated animals included in a vaccination/infection trial performed in our laboratory as well as more than 1000 serum and milk samples obtained from naturally infected and S19-vaccinated animals from Argentina. Our results demonstrate that OAg-AcrA-based assays are highly accurate for diagnosis of bovine brucellosis, even in vaccinated herds, using different types of samples and in different platforms. We propose this novel recombinant glycoprotein as an antigen suitable for the development of new standard immunological tests for screening and confirmatory diagnosis of bovine brucellosis in regions or countries with brucellosis-control programs. Copyright © 2014 Elsevier B.V. All rights reserved.
Richomme, Céline; Boadella, Mariana; Courcoul, Aurélie; Durand, Benoît; Drapeau, Antoine; Corde, Yannick; Hars, Jean; Payne, Ariane; Fediaevsky, Alexandre; Boschiroli, María Laura
2013-01-01
The Eurasian wild boar (Sus scrofa) is increasingly considered as a relevant actor in the epidemiology of animal tuberculosis (TB). Therefore, monitoring TB in wild boar becomes a key tool for establishing comprehensive control schemes for this disease. To estimate the exposure of free living wild boar to Mycobacterium tuberculosis complex (MTC) in France, a bovine-purified protein derivative based ELISA was used to test 2,080 archived serum samples of hunter-harvested animals in 58 French "départements". Two cut-off values were used for diagnostic interpretation: 0.2, recommended by the manufacturer (specificity: 96.43%; sensitivity: 72.6%), and 0.5 (specificity: 100%; sensitivity: 64%). During the same period, at the 0.2 cut-off, global true seroprevalence was 5.9% (IC95%: 4.3%-7.7%) and 76% of the sampled "départements" had seropositive wild boar, including seven cattle TB-free "départements. At the 0.5 cut-off, global true seroprevalence was 2.2% (IC95%: 1.5-3.2) and positive wild boar belonged to 21% of the "départements". All but one of these positive "départements" had reported at least one cattle TB outbreak since 2000. A good consistence between seropositive wild boar and TB outbreaks in cattle was found, especially at the 0.5 cut-off value (the mean distance to the nearest cattle TB outbreak was 13 km and 27 km for seropositive and seronegative wild boar, respectively; P<0.05). The use of an ELISA to detect MTC antibodies in wild boar has permitted the description of the geographic distribution of MTC contact in wild boar in France. Our results suggest that the ELISA could be used as a first screening tool to conduct TB surveillance in wild boar at a population level. High-risk wild boar populations (e.g. overabundant) could be tested and if identified positive by ELISA they should be surveyed in detail by combining pathology and culture.
Richomme, Céline; Boadella, Mariana; Courcoul, Aurélie; Durand, Benoît; Drapeau, Antoine; Corde, Yannick; Hars, Jean; Payne, Ariane; Fediaevsky, Alexandre; Boschiroli, María Laura
2013-01-01
The Eurasian wild boar (Sus scrofa) is increasingly considered as a relevant actor in the epidemiology of animal tuberculosis (TB). Therefore, monitoring TB in wild boar becomes a key tool for establishing comprehensive control schemes for this disease. To estimate the exposure of free living wild boar to Mycobacterium tuberculosis complex (MTC) in France, a bovine-purified protein derivative based ELISA was used to test 2,080 archived serum samples of hunter-harvested animals in 58 French “départements”. Two cut-off values were used for diagnostic interpretation: 0.2, recommended by the manufacturer (specificity: 96.43%; sensitivity: 72.6%), and 0.5 (specificity: 100%; sensitivity: 64%). During the same period, at the 0.2 cut-off, global true seroprevalence was 5.9% (IC95%: 4.3%-7.7%) and 76% of the sampled “départements” had seropositive wild boar, including seven cattle TB-free “départements. At the 0.5 cut-off, global true seroprevalence was 2.2% (IC95%: 1.5-3.2) and positive wild boar belonged to 21% of the “départements”. All but one of these positive “départements” had reported at least one cattle TB outbreak since 2000. A good consistence between seropositive wild boar and TB outbreaks in cattle was found, especially at the 0.5 cut-off value (the mean distance to the nearest cattle TB outbreak was 13km and 27km for seropositive and seronegative wild boar, respectively; P<0.05). The use of an ELISA to detect MTC antibodies in wild boar has permitted the description of the geographic distribution of MTC contact in wild boar in France. Our results suggest that the ELISA could be used as a first screening tool to conduct TB surveillance in wild boar at a population level. High-risk wild boar populations (e.g. overabundant) could be tested and if identified positive by ELISA they should be surveyed in detail by combining pathology and culture. PMID:24167584
[Serological diagnosis of whooping cough using immunoblot methods].
Lochman, I; Pokorná, L; Mertová, H
2017-01-01
The aim of this study was to challenge the conclusion presented in the current recommendations of the EU Perstrain Group (European group of reference laboratories) [17] that immunoblotting methods are not appropriate serological methods for the diagnosis of pertussis because their results cannot be quantified. To consider benefits of these methods for the diagnosis of Bordetella infections was another aim of this work. The residual sera from routine testing intended for disposal and results of routine tests for Bordetella infections performed in Spadia Lab in 2015 and 2016 were used in this study. The test samples were anonymized. Standard commercial ELISA and immunoblot kits were used for analyses. Using the TestLine Clinical Diagnostics Company kits, we have shown that, contrary to the conclusion of the EU Perstrain Group, quantification of the immunoblot results is possible and that these methods can improve the diagnosis of Bordetella infections, ultimately making it more effective.
Development of monoclonal antibody-based sandwich ELISA for detection of dextran.
Wang, Sheng-Yu; Li, Zhe; Wang, Xian-Jiang; Lv, Sha; Yang, Yun; Zeng, Lian-Qiang; Luo, Fang-Hong; Yan, Jiang-Hua; Liang, Da-Feng
2014-10-01
Dextran as anti-nutritional factor is usually a result of bacteria activity and has associated serial problems during the process stream in the sugar industry and in medical therapy. A sensitive method is expected to detect dextran quantitatively. Here we generated four monoclonal antibodies (MAbs) against dextran using dextran T40 conjugated with bovine serum albumin (BSA) as immunogen in our lab following hybridoma protocol. Through pairwise, an MAb named D24 was determined to be conjugated with horseradish peroxidase (HRP) and was used in the establishment of a sensitive sandwich enzyme-linked immunosorbent assay (ELISA) method for determination of dextran, in which MAb D9 was chosen as a capture antibody. The detection limit and working scope of the developed sandwich ELISA method were 3.9 ng/mL and 7.8-500 ng/mL with a correlation coefficient of 0.9909. In addition, the cross-reaction assay demonstrated that the method possessed high specificity with no significant cross-reaction with dextran-related substances, and the recovery rate ranged from 96.35 to 102.00%, with coefficient of variation ranging from 1.58 to 6.94%. These results indicated that we developed a detection system of MAb-based sandwich ELISA to measure dextran and this system should be a potential tool to determine dextran levels.
Franklin, Ashley D; Crosier, Adrienne E; Vansandt, Lindsey M; Mattson, Elliot; Xiao, Zhengguo
2015-06-01
Peripheral blood mononuclear cells (PBMCs) were isolated from the whole blood of cheetahs (Acinonyx jubatus ; n=3) and stimulated with lipopolysaccharides (LPS) to induce the production of proinflammatory cytokines TNF-α, IL-1β, and IL-6 for establishment of cross-reactivity between these cheetah cytokines and feline-specific cytokine antibodies provided in commercially available Feline DuoSet® ELISA kits (R&D Systems, Inc., Minneapolis, Minnesota 55413, USA). This study found that feline-specific cytokine antibodies bind specifically to cheetah proinflammatory cytokines TNF-α, IL-1β, and IL-6 from cell culture supernatants. The assays also revealed that cheetah PBMCs produce a measurable, cell concentration-dependent increase in proinflammatory cytokine production after LPS stimulation. To enable the use of these kits, which are designed for cell culture supernatants for analyzing cytokine concentrations in cheetah serum, percent recovery and parallelism of feline cytokine standards in cheetah serum were also evaluated. Cytokine concentrations in cheetah serum were approximated based on the use of domestic cat standards in the absence of cheetah standard material. In all cases (for cytokines TNF-α, IL-1β, and IL-6), percent recovery increased as the serum sample dilution increased, though percent recovery varied between cytokines at a given dilution factor. A 1:2 dilution of serum resulted in approximately 45, 82, and 7% recovery of TNF-α, IL-1β, and IL-6 standards, respectively. Adequate parallelism was observed across a large range of cytokine concentrations for TNF-α and IL-1β; however, a significant departure from parallelism was observed between the IL-6 standard and the serum samples (P=0.004). Therefore, based on our results, the Feline DuoSet ELISA (R&D Systems, Inc.) kits are valid assays for the measurement of TNF-α and IL-1β in cheetah serum but should not be used for accurate measurement of IL-6.
Quantitative detection of PfHRP2 in saliva of malaria patients in the Philippines
2012-01-01
Background Malaria is a global health priority with a heavy burden of fatality and morbidity. Improvements in field diagnostics are needed to support the agenda for malaria elimination. Saliva has shown significant potential for use in non-invasive diagnostics, but the development of off-the-shelf saliva diagnostic kits requires best practices for sample preparation and quantitative insight on the availability of biomarkers and the dynamics of immunoassay in saliva. This pilot study measured the levels of the PfHRP2 in patient saliva to inform the development of salivary diagnostic tests for malaria. Methods Matched samples of blood and saliva were collected between January and May, 2011 from eight patients at Palawan Baptist Hospital in Roxas, Palawan, Philippines. Parasite density was determined from thick-film blood smears. Concentrations of PfHRP2 in saliva of malaria-positive patients were measured using a custom chemiluminescent ELISA in microtitre plates. Sixteen negative-control patients were enrolled at UCLA. A substantive difference between this protocol and previous related studies was that saliva samples were stabilized with protease inhibitors. Results Of the eight patients with microscopically confirmed P. falciparum malaria, seven tested positive for PfHRP2 in the blood using rapid diagnostic test kits, and all tested positive for PfHRP2 in saliva. All negative-control samples tested negative for salivary PfHRP2. On a binary-decision basis, the ELISA agreed with microscopy with 100 % sensitivity and 100 % specificity. Salivary levels of PfHRP2 ranged from 17 to 1,167 pg/mL in the malaria-positive group. Conclusion Saliva is a promising diagnostic fluid for malaria when protein degradation and matrix effects are mitigated. Systematic quantitation of other malaria biomarkers in saliva would identify those with the best clinical relevance and suitability for off-the-shelf diagnostic kits. PMID:22631858
Han, Shuizhong; Xiao, Yan; Zheng, Dingding; Gu, Yanli; Xuan, Yajie; Jin, Yudan; Pang, Wenqiang; Huang, Yuxin; Li, Xiangdong; Deng, Junhua; Tian, Kegong
2016-08-26
Porcine cirovirus type 1 (PCV1) and type 2 (PCV2) are circulating in Chinese pig herds and the infected pigs develop antibodies to both viruses. Current commercial available ELISA kits cannot differentiate PCV2-specific antibodies from the mixtures of PCV1 and PCV2 antibodies in PCV1/2-infected or PCV2-vaccinated pigs. Therefore, the need for developing PCV2-specific ELISA methods is urgent to evaluate PCV2 antibody level in exclusion of PCV1 antibody interference after PCV2 vaccination. Virus-like particles (VLPs) of PCV2 based on the recombinant Cap protein were expressed in Escherichia coli. A competing ELISA was established by using the VLPs as coating antigen and a PCV2-specific monoclonal antibody as the competing antibody. The competing ELISA was compared with the results obtained by using an immunoperoxidase monolayer assay on 160 serum samples. The sensitivity and specificity of this competing ELISA were determined as 96.5 and 96.0 %, at 2 standard deviation from the mean or 91.8 and 100 % at 3 standard deviations from the mean. Next, a serological survey of 1297 vaccinated serum samples collected from commercial pig herds in Beijing, Hunan and Henan provinces in China was conducted. The results showed that 85.9 % of sera having positive PCV2 antibodies. The competing ELISA we developed in this study was both sensitive and specific to PCV2 and was suitable for large-scale PCV2 antibody monitoring in exclusion of PCV1 antibody interference after PCV2 vaccination.
NASA Astrophysics Data System (ADS)
Hosseini, Samira; Ibrahim, Fatimah; Djordjevic, Ivan; Rothan, Hussin A.; Yusof, Rohana; van der Marel, Cees; Koole, Leo H.
2014-10-01
Despite the known drawbacks of enzyme-linked immunosorbent assay (ELISA), one of the deficiencies that have relatively been ignored is the performance of ELISA substrate itself. Polystyrene (PS), as the cost effective material of choice for mass production of ELISA well-plates, has shown obvious lacks of suitable physical and chemical properties for protein attachment. The general concept of this work was to develop a potential substrate that can be suggested as a material of choice for production of a new generation of ELISA analytical kits. Spin-coated thin films of polymethyl methacrylate-co-methacrylic acid (PMMA-co-MAA) on silicon surfaces were designed and processed for detection of dengue virus. Coated surfaces of different molar ratios have been investigated as carboxyl-functionalized layers for obtaining platform for biomolecule immobilization with high level of protein activity. To improve the sensitivity of detection, we have used amine functional "spacers", hexamethylenediamine (HMDA) and polyethyleneimine (PEI), which were covalently bonded to the surfaces of PMMA-co-MAA coatings. Results demonstrate that the variation of surface concentration of carboxyl groups of PMMA-co-MAA can be used to control the amine surface concentration after carbodiimide coupling with HMDA and PEI spacers. The presence of amine spacers increases hydrophilicity of the coatings and significantly impacts the polymer surface morphology. In particular, protein immobilization via amine-bearing spacers has been achieved in two effective steps: (1) carbodiimide bonding between amine spacer molecules and PMMA-co-MAA polymer coatings; and (2) covalent immobilization of antibody via glutaraldehyde reaction with amine groups from amine-treated surfaces. The application of PEI spacer in comparison to HMDA has shown much higher intensity of detection signal in ELISA experiment, indicating better immobilization efficiency and preservation of antibody activity upon attachment to the polymer surface.
Gurung, R B; Begg, D J; Purdie, A C; Eamens, G J; Whittington, R J
2015-12-01
An enzyme-linked immunosorbent assay (ELISA) was developed and optimised using a Mycobacterium avium subspecies paratuberculosis (MAP) antigen prepared from a C strain (316v) passed through a French press. The optimised assay was evaluated with a panel of sera from MAP infected (n = 66) and uninfected (n = 1,092) sheep. Animals in the MAP infected category were positive on either tissue culture or histopathology but were of unknown serum antibody status. The diagnostic performance and cost of the assay were compared with those of a commercial ELISA (IDEXX). At 99.8% diagnostic specificity the assay showed a diagnostic sensitivity of 23% (95% CI: 15.1-35.8) compared with 36.4% (95% CI: 25.8-48.4) for the commercial ELISA (McNemar's test: chi-square 5.82, p < 0.05). The sensitivities were 5.9% (95% CI: 1-26.9), 27.9% (95% CI: 14.7-45.7) and 35% (95% CI: 18.1-56.7), for low grade, paucibacillary and multibacillary lesion grades, respectively. The cost of the commercial assay kit was 2.7 to 5.2 times greater than that of the 316v ELISA for an equivalent number of tests, the multiple depending on the number of plates processed per run. For flock-level surveillance, to account for the lower sensitivity of the 316v ELISA compared with the commercial ELISA, sample sizes would be increased but the test cost would still be lower. The 316v assay will be useful for diagnosis of Johne's disease in sheep flocks, particularly in developing countries where labour costs are low relative to the cost of consumables.
Enterocytozoon bieneusi in Bovine Viral Diarrhea Virus (BVDV) infected and noninfected cattle herds.
Juránková, J; Kamler, M; Kovařčík, K; Koudela, B
2013-02-01
Enterocytozoon bieneusi known as a causative agent of opportunistic infections instigating diarrhoea in AIDS patients was identified also in a number of immunocompetent patients and in a wide range of animals, including cattle. In the present study we tested if the Bovine Viral Diarrhea Virus (BVDV), the most common pathogen underlying immunosuppressive Bovine Viral Diarrhoea (BVD), can enhance the occurrence of opportunistic infections with E. bieneusi in cattle. Six dairy farms were investigated using ELISA to detect antibodies against or antigens arising from BVDV in collected sera. A total of 240 individual faecal samples from four age groups were examined for the presence of E. bieneusi by nested PCR. Sequence analysis of six E. bieneusi positive samples revealed the presence of the genotype I of E. bieneusi, previously described in cattle. The hypothesis expecting higher prevalence of E. bieneusi in BVDV positive cattle herds was not confirmed in this study; however this is the first description about E. bieneusi in cattle in the Czech Republic. Copyright © 2012 Elsevier Ltd. All rights reserved.
Loughney, John W; Lancaster, Catherine; Ha, Sha; Rustandi, Richard R
2014-09-15
Bovine serum albumin (BSA) is a major component of fetal bovine serum (FBS), which is commonly used as a culture medium during vaccine production. Because BSA can cause allergic reactions in humans the World Health Organization (WHO) has set a guidance of 50 ng or less residual BSA per vaccine dose. Vaccine manufacturers are expected to develop sensitive assays to detect residual BSA. Generally, sandwich enzyme-linked immunosorbent assays (ELISA) are used in the industry to detect these low levels of BSA. We report the development of a new improved method for residual BSA detection using the SimpleWestern technology to analyze residual BSA in an attenuated virus vaccine. The method is based on automated Capillary Western and has linearity of two logs, >80% spike recovery (accuracy), intermediate precision of CV <15%, and LOQ of 5.2 ng/ml. The final method was applied to analyze BSA in four lots of bulk vaccine products and was used to monitor BSA clearance during vaccine process purification. Copyright © 2014 Elsevier Inc. All rights reserved.
Hagedorn, H W; Schulz, R; Jaeschke, G
1994-01-01
An enzyme linked immunosorbent assay (ELISA) was developed to detect the anabolic steroid boldenone in equine blood and urine. The polyclonal antiserum was raised in rabbits, employing boldenone-17-hemisuccinate-bovine serum albumin as antigen. Boldenone-17-hemisuccinate-horseradish peroxidase served as enzyme conjugate. Sensitivity of the assay was 26.0 +/- 3.0 pg/well. Among the endogenous steroids tested only progesterone and testosterone exhibited moderate cross-reactivities, 3.4 and 2.5%, respectively. These cross-reactivities are of no importance for the boldenone assay. For the reduction of background levels, screening for boldenone of equine serum was performed after extraction. Urine samples were determined directly after dilution, omitting hydrolysis of boldenone conjugates. Positive screening results were confirmed by means of two independent HPLC systems combined with off-line detection, employing the boldenone ELISA. Methandienone served as internal standard to ascertain retention factors. In horses treated with boldenone-17-undecylenate the presence of boldenone in serum was confirmed up to 28 days and in unhydrolyzed urine up to 56 days post applicationem.
Zhang, Zhiyang; Chen, Zhaopeng; Wang, Shasha; Cheng, Fangbin; Chen, Lingxin
2015-12-23
Here, we propose a plasmonic enzyme-linked immunosorbent assay (ELISA) based on highly sensitive colorimetric detection of alkaline phosphatase (ALP), which is achieved by iodine-mediated etching of gold nanorods (AuNRs). Once the sandwich-type immunocomplex is formed, the ALP bound on the polystyrene microwells will hydrolyze ascorbic acid 2-phosphate into ascorbic acid. Subsequently, iodate is reduced to iodine, a moderate oxidant, which etches AuNRs from rod to sphere in shape. The shape change of AuNRs leads to a blue-shift of longitudinal localized surface plasmon resonance. As a result, the solution of AuNRs changes from blue to red. Benefiting from the highly sensitive detection of ALP, the proposed plasmonic ELISA has achieved an ultralow detection limit (100 pg/mL) for human immunoglobulin G (IgG). Importantly, the visual detection limit (3.0 ng/mL) allows the rapid differential diagnosis with the naked eye. The further detection of human IgG in fetal bovine serum indicates its applicability to the determination of low abundance protein in complex biological samples.
Sidibé, Cheick Abou Kounta; Grosbois, Vladimir; Thiaucourt, François; Niang, Mamadou; Lesnoff, Matthieu; Roger, François
2012-08-01
A Bayesian approach, allowing for conditional dependence between two tests was used to estimate without gold standard the sensitivities of complement fixation test (CFT) and competitive enzyme-linked immunosorbent assay test (cELISA) and the serological prevalence of CBPP in a cattle population of the Central Delta of the Niger River in Mali, where CBPP is enzootic and the true prevalence and animals serological state were unknown. A significant difference (P = 0.99) was observed between the sensitivities of the two tests, estimated at 73.7% (95% probability interval [PI], 63.4-82.7) for cELISA and 42.3% (95% PI, 33.3-53.7) for CFT. Individual-level serological prevalence in the study population was estimated at 14.1% (95% PI, 10.8-16.9). Our results indicate that in enzootic areas, cELISA performs better in terms of sensitivity than CFT. However, negative conditional sensitivity dependence between the two tests was detected, implying that to achieve maximum sensitivity, the two tests should be applied in parallel.
Schuster, Isolde; Mertens, Marc; Köllner, Bernd; Korytář, Tomáš; Keller, Markus; Hammerschmidt, Bärbel; Müller, Thomas; Tordo, Noël; Marianneau, Philippe; Mroz, Claudia; Rissmann, Melanie; Stroh, Eileen; Dähnert, Lisa; Hammerschmidt, Felicitas; Ulrich, Rainer G; Groschup, Martin H
2016-10-01
Crimean-Congo hemorrhagic fever virus (CCHFV) circulates in many countries of Asia, Africa, and Europe. CCHFV can cause a severe hemorrhagic fever in humans with case-fatality rates of up to 80%. CCHF is considered to be one of the major emerging diseases spreading to and within Europe. Ticks of the genus Hyalomma function as vector as well as natural reservoir of CCHFV. Ticks feed on various domestic animals (e.g. cattle, sheep, goats) and on wildlife (e.g. hares, hedgehogs). Those animal species play an important role in the life cycle of the ticks as well as in amplification of CCHFV. Here we present a competitive ELISA (cELISA) for the species-independent detection of CCHFV-specific antibodies. For this purpose nucleocapsid (N) protein specific monoclonal antibodies (mAbs) were generated against an Escherichia coli (E. coli) expressed CCHFV N-protein. Thirty-three mAbs reacted with homologous and heterologous recombinant CCHFV antigens in ELISA and Western blot test and 20 of those 33 mAbs reacted additionally in an immunofluorescence assay with eukaryotic cells expressing the N-protein. Ten mAbs were further characterized in a prototype of the cELISA and nine of them competed with positive control sera of bovine origin. The cELISA was established by using the mAb with the strongest competition. For the validation, 833 sera from 12 animal species and from humans were used. The diagnostic sensitivity and specificity of the cELISA was determined to be 95% and 99%, respectively, and 2% of the sera gave inconclusive results. This cELISA offers the possibility for future large-scale screening approaches in various animal species to evaluate their susceptibility to CCHFV infection and to identify and monitor the occurrence of CCHFV. Copyright © 2016 Elsevier B.V. All rights reserved.
Evidence for enzootic circulation of Rift Valley fever virus among livestock in Cameroon.
Rissmann, M; Eiden, M; Wade, A; Poueme, R; Abdoulkadiri, S; Unger, H; Ziegler, U; Homeier, T; Groschup, M H
2017-08-01
Rift Valley fever virus (RVFV) is an arthropod-borne pathogen, causing serious epidemics in Africa and the Arabian Peninsula. In Cameroon serological data indicate the presence of RVFV, but active circulation of RVFV, causing clinical infections has not been proven yet. For this purpose we carried out a serological and molecular study on a total of 1953 randomly selected serum samples of small ruminants and cattle, which were collected in years 2013 and 2014 in Cameroon. In a first step, sera were screened serologically using a variety of assay formats to reveal RVFV specific antibodies. At the second stage, seropositive specimen were assessed for acute RVFV infections via IgM-specific ELISA and quantitative real-time RT-PCR. Our data show a significant difference in the antibody prevalence in cattle (13.5% [95% confidence interval: 11.4-15.7]) and small ruminants (3.4% [95% confidence interval: 2.3-4.7]), with indications for annual fluctuations and significant regional differences of seropositivity. One small ruminant and three bovines were eventually found to be positive in IgM ELISA and indications for viremia were found in one bovine by RVFV genome detection using quantitative real-time RT-PCR. The results of this study therefore corroborate the presence of acute RVFV-infection and its circulation in Cameroon. Copyright © 2017 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perkins, J; Parida, S; Clavijo, A
2007-05-14
Liquid array technology has previously been used to show proof-of-principle of a multiplexed non structural protein serological assay to differentiate foot-and-mouth infected and vaccinated animals. The current multiplexed assay consists of synthetically produced peptide signatures 3A, 3B and 3D and recombinant protein signature 3ABC in combination with four controls. To determine diagnostic specificity of each signature in the multiplex, the assay was evaluated against a naive population (n = 104) and a vaccinated population (n = 94). Subsequently, the multiplexed assay was assessed using a panel of bovine sera generated by the World Reference Laboratory for foot-and-mouth disease in Pirbright,more » UK. This sera panel has been used to assess the performance of other singleplex ELISA-based non-structural protein antibody assays. The 3ABC signature in the multiplexed assay showed comparative performance to a commercially available non-structural protein 3ABC ELISA (Cedi test{reg_sign}) and additional information pertaining to the relative diagnostic sensitivity of each signature in the multiplex is acquired in one experiment. The encouraging results of the evaluation of the multiplexed assay against a panel of diagnostically relevant samples promotes further assay development and optimization to generate an assay for routine use in foot-and-mouth disease surveillance.« less
Olotu, Amadin A; Oyelese, Adesola O; Salawu, Lateef; Audu, Rosemary A; Okwuraiwe, Azuka P; Aboderin, Aaron O
2016-05-05
Hepatitis B virus (HBV) transmission through blood transfusion is reduced by screening for hepatitis B surface antigen (HBsAg). However this method cannot detect the presence of occult hepatitis B virus infection. This study sought to determine the prevalence of occult hepatitis B virus infection among blood donors in Ile-Ife, Nigeria. For the first time in Nigeria we employed an automated real-time PCR- method to investigate the prevalence of occult HBV in blood donors. Blood donors screened with HBsAg immunochromatographic rapid test kits at the blood transfusion units of two hospitals and found to be negative were recruited into the study. Questionnaires to elicit risk factors for HBV infection were administered and then 10 ml of blood was collected from each donor. Plasma samples obtained from these HBsAg negative blood donors were screened again for HBsAg using an enzyme-linked immunosorbent assay (ELISA) method, and those found negative were screened for the presence of total antibody to the HBV core antigen (anti-HBc) using ELISA method. Those positive to anti-HBc were then tested for HBV DNA, using an automated real-time PCR method. Five hundred and seven blood donors found HBsAg negative by immunochromatographic rapid test kits at both blood transfusion units, were tested for HBsAg using ELISA and 5 (1 %) were HBsAg positive. The 502 found negative were tested for anti-HBc and 354 (70.5 %) were found positive implying previous exposure to HBV and 19 (5.4 %) of the 354 anti-HBc positive had HBV DNA signifying occult HBV infection. No risk factors were found to be associated with the presence of HBV DNA among those who tested positive. Occult HBV infection exists in blood donors in Ile-Ife, Nigeria and the use of HBsAg alone for screening prospective donors will not eliminate the risk of HBV transmission in blood transfusion or stem cell transplantation.
Performance characteristics of an ELISA screening assay for urinary synthetic cannabinoids.
Spinelli, Eliani; Barnes, Allan J; Young, Sheena; Castaneto, Marisol S; Martin, Thomas M; Klette, Kevin L; Huestis, Marilyn A
2015-06-01
Synthetic cannabinoids are marketed as legal alternatives to cannabis, as routine urine cannabinoid immunoassays do not detect synthetic cannabinoids. Laboratories are challenged to identify these new designer drugs that are widely available and represent a major public health and safety problem. Immunoassay testing offers rapid separation of presumptive positive and negative specimens, prior to more costly and time-consuming chromatographic confirmation. The Neogen SPICE ELISA kit targets JWH-018 N-pentanoic acid as a marker for urinary synthetic cannabinoids. Assay performance was evaluated by analyzing 2469 authentic urine samples with the Neogen immunoassay and liquid chromatography-tandem mass spectrometry (LC-MS/MS). Two immunoassay cut-off concentrations, 5 and 10 µg/L, classified samples as presumptive positive or negative, followed by qualitative LC-MS/MS confirmation for 29 synthetic cannabinoids markers with limits of detection of 0.5-10 µg/L to determine the assay's sensitivity, specificity and efficacy. Challenges at ±25% of each cut-off also were investigated to determine performance around the cut-off and intra- and inter-plate imprecision. The immunoassay was linear from 1 to 250 µg/L (r(2) = 0.992) with intra- and inter-plate imprecision of ≤5.3% and <9%, respectively. Sensitivity, specificity, and efficiency results with the 5 µg/L cut-off were 79.9%, 99.7%, and 97.4% and with the 10 µg/L cut-off 69.3%, 99.8%, and 96.3%, respectively. Cross-reactivity was shown for 18 of 73 synthetic cannabinoids markers evaluated. Good sensitivity, specificity, and efficiency, lack of sample preparation requirements, and rapid semi-automation documented that the Neogen SPICE ELISA kit is a viable method for screening synthetic cannabinoids in urine targeting JWH-018 N-pentanoic acid. Copyright © 2014 John Wiley & Sons, Ltd.
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System
Tyagi, Surabhi; Tyagi, Alok
2013-01-01
Background: Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. Aim: To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. Material and Methods: All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti–HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme–linked immunosorbent assay (ELISA) technique using micro–elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. Statistical Analysis: The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Results: Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Conclusion: Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think…. PMID:24179900
Possible Correlation of Transfusion Transmitted Diseases with Rh type and ABO Blood Group System.
Tyagi, Surabhi; Tyagi, Alok
2013-09-01
Screening of blood is mandatory for transfusion transmitted diseases and is routinely done in the blood banks. As blood is the major source transmission of hepatitis B, hepatitis C, human immunodeficiency virus & many other diseases the hazards can be minimised by effective donor selection and screening. To find out the correlation between the transfusion transmitted diseases and blood groups and the seroprevalence of HIV, HBV, HCV & syphilis among the apparently healthy human blood donors. Study, Setting & Design: This retrospective study was conducted at the blood bank of a tertiary health care teaching centre for a period of four years. All voluntary and replacement donors reporting to the blood bank were screened for HIV-1 & 2, HBsAg, HCV and Syphilis. Anti-HIV -1 & 2, HBsAg & anti - HCV was tested using the appropriate Enzyme-linked immunosorbent assay (ELISA) technique using micro-elisa kit supplied by J.Mitra & Co.Ltd. The seropositive samples were again tested on ELISA kits of RFCL &/or BIORAD for further confirmation & ruling out any false positive or false negative results. The rapid plasma reagain (RPR) test was used for estimation of syphilis infection. The data entry was carried out using Microsoft office excel worksheet and was analysed by percentage and comparison. Total of 6000 donors were screened which included voluntary and replacement donors. Seroprevalence of HIV (0.1833 %), HCV (1.28%), HBsAg (1.5833 %) and syphilis (0.4333 %) was detected. In the study done it was also noted - that the NEGATIVE blood groups were more prone to TTIs. Blood group A negative was more prone to TTIs with HIV, HBsAg and VDRL while blood group B negative was more affected by HCV. Seroprevalence of these infections shows that routine screening is a must for blood and blood product safe transfusion. Do negative blood groups predispose to TTIs? A finding which makes us think….
Duration of antibody response following vaccination against feline immunodeficiency virus.
Westman, Mark E; Malik, Richard; Hall, Evelyn; Harris, Matthew; Hosie, Margaret J; Norris, Jacqueline M
2017-10-01
Objectives Recently, two point-of-care (PoC) feline immunodeficiency virus (FIV) antibody test kits (Witness and Anigen Rapid) were reported as being able to differentiate FIV-vaccinated from FIV-infected cats at a single time point, irrespective of the gap between testing and last vaccination (0-7 years). The aim of the current study was to investigate systematically anti-FIV antibody production over time in response to the recommended primary FIV vaccination series. Methods First, residual plasma from the original study was tested using a laboratory-based ELISA to determine whether negative results with PoC testing were due to reduced as opposed to absent antibodies to gp40. Second, a prospective study was performed using immunologically naive client-owned kittens and cats given a primary FIV vaccination series using a commercially available inactivated whole cell/inactivated whole virus vaccine (Fel-O-Vax FIV, three subcutaneous injections at 4 week intervals) and tested systematically (up to 11 times) over 6 months, using four commercially available PoC FIV antibody kits (SNAP FIV/FeLV Combo [detects antibodies to p15/p24], Witness FeLV/FIV [gp40], Anigen Rapid FIV/FeLV [p24/gp40] and VetScan FeLV/FIV Rapid [p24]). Results The laboratory-based ELISA showed cats from the original study vaccinated within the previous 0-15 months had detectable levels of antibodies to gp40, despite testing negative with two kits that use gp40 as a capture antigen (Witness and Anigen Rapid kits). The prospective study showed that antibody testing with SNAP Combo and VetScan Rapid was positive in all cats 2 weeks after the second primary FIV vaccination, and remained positive for the duration of the study (12/12 and 10/12 cats positive, respectively). Antibody testing with Witness and Anigen Rapid was also positive in a high proportion of cats 2 weeks after the second primary FIV vaccination (8/12 and 7/12, respectively), but antibody levels declined below the level of detection in most cats (10/12) by 1 month after the third (final) primary FIV vaccination. All cats tested negative using Witness and Anigen Rapid 6 months after the third primary FIV vaccination. Conclusions and relevance This study has shown that a primary course of FIV vaccination does not interfere with FIV antibody testing in cats using Witness and Anigen Rapid, provided primary vaccination has not occurred within the previous 6 months. Consequently, Witness and Anigen Rapid antibody test kits can be used reliably to determine FIV infection status at the time of annual booster FIV vaccination to help detect 'vaccine breakthroughs' and in cats that have not received a primary course of FIV vaccination within the preceding 6 months. The duration of antibody response following annual booster FIV vaccination and the resulting effect on antibody testing using PoC kits needs to be determined by further research. The mechanism(s) for the variation in FIV antibody test kit performance remains unclear.
[Assessment Method of Remnant α-1, 3-galactosyle Epitopes in Animal Tissue-derived Biomaterials].
Shan, Yongqiang; Xu, Liming; Ke, Linnan; Lu, Yan; Shao, Anliang; Zhang, Na; Zeng, Bixin
2015-06-01
The aim of this study was to establish an assessment method for determining α-Gal (α-1, 3-galactosyle) epitopes contained in animal tissue or animal tissue-derived biological materials with ELISA inhibition assay. Firstly, a 96 well plate was coated with Gal α-1, 3-Gal/bovine serum albumin (BSA) as a solid phase antigen and meanwhile, the anti-α-Gal M86 was used to react with α-Gal antigens which contained in the test materials. Then, the residual antibodies (M86) in the supernatant of M86-Gal reaction mixture were measured using ELISA inhibition assay by the α-Gal coating plate. The inhibition curve of the ELISA inhibition assay, the R2 = 0.999, was well established. Checking using both α-Gal positive materials (rat liver tissues) and α-Gal negative materials (human placenta tissues) showed a good sensitivity and specificity. Based on the presently established method, the α-Gal expression profile of rat tissues, decellular animal tissue-derived biological materials and porcine dermal before and after decellular treatment were determined. The M86 ELISA inhibition assay method, which can quantitatively determine the α-Gal antigens contained in animal tissues or animal tissue-derived biomaterials, was refined. This M86 specific antibody based-ELISA inhibition assay established in the present study has good sensitivity and specificity, and could be a useful method for determining remnant α-1, 3Gal antigens in animal tissue-derived biomaterials.
Seroprevalence of East Coast fever in Central Equatoria State, South Sudan.
Marcellino, Wani L; Salih, Diaeldin A; Julla, Ibrahim I; El Hussein, Abdel Rahim M
2012-01-01
A cross-sectional survey was conducted in 2005 in different cattle camps in Juba, Mangalla and Terekeka localities of Central Equatoria State, South Sudan. Serum samples were collected from 514 cattle of different age groups. Samples were analysed using an indirect enzyme-linked immunosorbent assay (ELISA) with commercially available polymorphic immunodominant molecule (PIM) ELISA kits. The overall serological prevalence of Theileria parva was 70.8% (364/514). The highest rate of prevalence was observed in Mangalla (91.2%) and the lowest in Juba (61.8%), with Terekeka recording 71.8%. Regarding the age groups, older cattle (over four years of age) showed a significantly higher rate of prevalence (p>0.001) than calves (below one year of age). The implications of these results in the overall epidemiology of East Coast fever in South Sudan are discussed and possible recommendations for future implementation of disease control measures are outlined.
Jabarpour, Masoome; Tajik, Parviz
2017-01-01
Background: Spermatogonial stem cells (SSCs) are undifferentiated cells which are highly reproducible and expandable. Several studies have been conducted to reproduce these cells in culture. They used growth factors, hormones and different feeder cells to improve survival and proliferation of SSCs. Objective: This study was conducted to evaluate the effects of follicular stimulating hormone (FSH) on gene expression of fibroblast growth factor (FGF2) and glial cell-derived neurotrophic factor (GDNF) in Sertoli cells. Materials and Methods: Sertoli cells and SSCs were isolated from 3-5 month-old calves. Bovine testicular cells were cultured for 15 days with or without FSH. Identification of these cells was confirmed by immunocytochemistry analysis. Colony formation of SSCs was evaluated using an inverted microscope. The gene expression of FGF2 and GDNF and the gene markers bcl6b, thy-1, and C-kit were evaluated using the quantitative RT-PCR technique. Results: The results indicated that FSH increased colonization of SSCs. the expression of GDNF, FGF2, and markers of undifferentiated spermatogonia was increased following culture in control and FSH groups (p<0.05), this increase was more in FSH group. Conversely, the expression of C-kit was decreased in both groups (p<0.05). Conclusion: The results showed that FSH can increase the self-renewal of SSCs in vitro via upregulation of GDNF and FGF2 expression in Sertoli cells. PMID:29492477
Transfer of single dose of intravitreal injection of ranibizumab and bevacizumab into milk of sheep
Cakmak Argun, Tugba; Yalcin Tok, Ozlem; Tok, Levent; Yilmaz, Gulsen; Meric Yilmaz, Fatma; Gunes, Alime; Argun, Mehmet; Butuner, Osman
2017-01-01
AIM To investigate whether single-dose intravitreal injections of bevacizumab and ranibizumab transfer into milk. METHODS This study included lactating 12 sheep and a single 3-month old suckling lamb of each sheep. Two groups consisting of 6 sheep and their lambs were constituted; the ranibizumab group and the bevacizumab group before the administration of intravitreal injections, blood and milk samples were obtained from all sheep and, following the injections, blood and milk samples of all sheep and blood samples of all lambs were collected at regular time points. Serum and milk concentrations of bevacizumab and ranibizumab were measured using an enzyme-linked immunosorbent assay (ELISA) kit. The limit of determination was 0.9 ng/mL for bevacizumab and 0.62 ng/mL for ranibizumab. RESULTS At 6h after intravitreal injections, bevacizumab concentration was above the limit of determination in the blood of all sheep. At 3wk, when the study was terminated, bevacizumab concentrations were high in 4 sheep. Even though bevacizumab concentrations in milk showed fluctuations, the drug transferred into the milk of all sheep at detectable concentrations. Ranibizumab drug concentrations in the blood and milk of sheep and those in the blood of lambs were below the limit of determination by the ELISA kit. CONCLUSION This sheep model study demonstrate that intravitreal injection of ranibizumab, which did not transfer into the milk of sheep and suckling lambs, is safer than bevacizumab during lactation period. PMID:28730108
Munawwar, Arshi; Sharma, Surendra K; Gupta, Somesh; Singh, Sarman
2014-12-01
In India Kaposi's sarcoma is rarely seen in AIDS patients. Hence the current belief is that the incidence of human herpesvirus-8 (HHV-8) is very low in this subcontinent, most probably due to the heterosexual route of HIV transmission. However, there is a scarcity of data on the prevalence of HHV-8 in India. In India the primary mode of HIV transmission is the heterosexual route. Therefore we aimed to determine the prevalence of antibodies against HHV-8 in North Indian HIV-infected men naive of antiretroviral therapy (ART). In a prospective study, 165 Indian adult males were recruited from an ART clinic. Blood samples were collected before administering any antiretroviral drug. The sera were tested for antibodies against HHV-8 using a commercial enzyme-linked immunosorbent assay (ELISA) kit, which detects IgG antibodies to lytic antigens of HHV-8. All positive samples were confirmed for the presence of anti-HHV-8 antibodies using an indirect immunofluorescence assay (IFA). The IFA kit is intended to detect primary, latent, persistent, or reactivated infection of HHV-8. Of the 165 males, 43 (26.06%) were positive by ELISA while 26 (15.8%) were also positive by IFA. Seroprevalence decreased with increasing age (p<0.05). Factors independently associated with HHV-8 infection were younger age group and alcohol consumption. These findings suggest that even in a heterosexual population, HHV-8 can be transmitted frequently.
Ezzatifar, Fatemeh; Majidi, Jafar; Baradaran, Behzad; Aghebati Maleki, Leili; Abdolalizadeh, Jalal; Yousefi, Mehdi
2015-01-01
Purpose: Monoclonal antibodies are potentially powerful tools used in biomedical research, diagnosis, and treatment of infectious diseases and cancers. The monoclonal antibody against Human IgA can be used as a diagnostic application to detect infectious diseases. The aim of this study was to improve an appropriate protocol for large-scale production of mAbs against IgA. Methods: For large-scale production of the monoclonal antibody, hybridoma cells that produce monoclonal antibodies against Human IgA were injected intraperitoneally into Balb/c mice that were previously primed with 0.5 ml Pristane. After ten days, ascitic fluid was harvested from the peritoneum of each mouse. The ELISA method was carried out for evaluation of the titration of produced mAbs. The ascitic fluid was investigated in terms of class and subclass by a mouse mAb isotyping kit. MAb was purified from the ascitic fluid by ion exchange chromatography. The purity of the monoclonal antibody was confirmed by SDS-PAGE, and the purified monoclonal antibody was conjugated with HRP. Results: Monoclonal antibodies with high specificity and sensitivity against Human IgA were prepared by hybridoma technology. The subclass of antibody was IgG1 and its light chain was the kappa type. Conclusion: This conjugated monoclonal antibody could have applications in designing ELISA kits in order to diagnose different infectious diseases such as toxoplasmosis and H. Pylori. PMID:25789225
Sanjay, Sharma T; Dou, Maowei; Sun, Jianjun; Li, XiuJun
2016-07-26
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.
Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, XiuJun
2016-01-01
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings. PMID:27456979
NASA Astrophysics Data System (ADS)
Sanjay, Sharma T.; Dou, Maowei; Sun, Jianjun; Li, Xiujun
2016-07-01
Enzyme linked immunosorbent assay (ELISA) is one of the most widely used laboratory disease diagnosis methods. However, performing ELISA in low-resource settings is limited by long incubation time, large volumes of precious reagents, and well-equipped laboratories. Herein, we developed a simple, miniaturized paper/PMMA (poly(methyl methacrylate)) hybrid microfluidic microplate for low-cost, high throughput, and point-of-care (POC) infectious disease diagnosis. The novel use of porous paper in flow-through microwells facilitates rapid antibody/antigen immobilization and efficient washing, avoiding complicated surface modifications. The top reagent delivery channels can simply transfer reagents to multiple microwells thus avoiding repeated manual pipetting and costly robots. Results of colorimetric ELISA can be observed within an hour by the naked eye. Quantitative analysis was achieved by calculating the brightness of images scanned by an office scanner. Immunoglobulin G (IgG) and Hepatitis B surface Antigen (HBsAg) were quantitatively analyzed with good reliability in human serum samples. Without using any specialized equipment, the limits of detection of 1.6 ng/mL for IgG and 1.3 ng/mL for HBsAg were achieved, which were comparable to commercial ELISA kits using specialized equipment. We envisage that this simple POC hybrid microplate can have broad applications in various bioassays, especially in resource-limited settings.
A two-site ELISA can quantify upregulation of SMN protein by drugs for spinal muscular atrophy.
Nguyen thi Man; Humphrey, E; Lam, L T; Fuller, H R; Lynch, T A; Sewry, C A; Goodwin, P R; Mackenzie, A E; Morris, G E
2008-11-25
Spinal muscular atrophy (SMA) is an autosomal recessive disorder characterized by loss of lower motor neurons during early or postnatal development. Severity is variable and is inversely related to the levels of survival of motor neurons (SMN) protein. The aim of this study was to produce a two-site ELISA capable of measuring both the low, basal levels of SMN protein in cell cultures from patients with severe SMA and small increases in these levels after treatment of cells with drugs. A monoclonal antibody against recombinant SMN, MANSMA1, was selected for capture of SMN onto microtiter plates. A selected rabbit antiserum against refolded recombinant SMN was used for detection of the captured SMN. The ratio of SMN levels in control fibroblasts to levels in SMA fibroblasts was greater than 3.0, consistent with Western blot data. The limit of detection was 0.13 ng/mL and SMN could be measured in human NT-2 neuronal precursor cells grown in 96-well culture plates (3 x 10(4) cells per well). Increases in SMN levels of 50% were demonstrable by ELISA after 24 hours treatment of 10(5) SMA fibroblasts with valproate or phenylbutyrate. A rapid and specific two-site, 96-well ELISA assay, available in kit format, can now quantify the effects of drugs on survival of motor neurons protein levels in cell cultures.
Evaluation of Six Recombinant Proteins for Serological Diagnosis of Lyme Borreliosis in China.
Liu, Wei; Liu, Hui Xin; Zhang, Lin; Hou, Xue Xia; Wan, Kang Lin; Hao, Qin
2016-05-01
In this study, we evaluated the diagnostic efficiency of six recombinant proteins for the serodiagnosis of Lyme borreliosis (LB) and screened out the appropriate antigens to support the production of a Chinese clinical ELISA (enzyme-linked immunosorbent assay) kit for LB. Six recombinant antigens, Fla B.g, OspC B.a, OspC B.g, P39 B.g, P83 B.g, and VlsE B.a, were used for ELISA to detect serum antibodies in LB, syphilis, and healthy controls. The ELISA results were used to generate receiver operating characteristic (ROC) curves, and the sensitivity and specificity of each protein was evaluated. All recombinant proteins were evaluated and screened by using logistic regression models. Two IgG (VlsE and OspC B.g) and two IgM (OspC B.g and OspC B.a) antigens were left by the logistic regression model screened. VlsE had the highest specificity for syphilis samples in the IgG test (87.7%, P<0.05). OspC B.g had the highest diagnostic value in the IgM test (AUC=0.871). Interactive effects between OspC B.a and Fla B.g could reduce the specificity of the ELISA. Three recombinant antigens, OspC B.g, OspC B.a, and VlsE B.a, were useful for ELISAs of LB. Additionally, the interaction between OspC B.a and Fla B.g should be examined in future research. Copyright © 2016 The Editorial Board of Biomedical and Environmental Sciences. Published by China CDC. All rights reserved.
Technical and financial evaluation of assays for progesterone in canine practice in the UK.
Moxon, R; Copley, D; England, G C W
2010-10-02
The concentration of progesterone was measured in 60 plasma samples from bitches at various stages of the oestrous cycle, using commercially available quantitative and semi-quantitative ELISA test kits, as well as by two commercial laboratories undertaking radioimmunoassay (RIA). The RIA, which was assumed to be the 'gold standard' in terms of reliability and accuracy, was the most expensive method when analysing more than one sample per week, and had the longest delay in obtaining results, but had minimal requirements for practice staff time. When compared with the RIA, the quantitative ELISA had a strong positive correlation (r=0.97, P<0.05) and a sensitivity and specificity of 70.6 per cent and 100.0 per cent, respectively, and positive and negative predictive values of 100.0 per cent and 71.0 per cent, respectively, with an overall accuracy of 90.0 per cent. This method was the least expensive when analysing five or more samples per week, but had longer turnaround times than that of the semi-quantitative ELISA and required more staff time. When compared with the RIA, the semi-quantitative ELISA had a sensitivity and specificity of 100.0 per cent and 95.5 per cent, respectively, and positive and negative predictive values of 73.9 per cent and 77.8 per cent, respectively, with an overall accuracy of 89.2 per cent. This method was more expensive than the quantitative ELISA when analysing five or more samples per week, but had the shortest turnaround time and low requirements in terms of staff time.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Liming; Du, Dan; Lu, Donglai
2011-05-05
A sandwich enzyme-linked immunosorbent assay (sELISA) is developed for detection of organophosphorylated butyrylcholinesterase (OP-BChE), a potential biomarker for human exposure to organophosphate insecticides and nerve agents. A pair of antibodies specific to OP-BChE adduct were identified through systematic screening of several anti BChE antibodies (anti-BChE) and anti-phosphoserine antibodies (anti-Pser) from different sources. The selected anti-BChE (set as capture antibody) antibodies recognize both phosphorylated and nonphosphorylated BChE. These antibodies can therefore be used to capture both BChE and OP-BChE from the sample matrices. The anti- Pser (set as detecting antibody) was used to recognize the OP moiety of OP-BChE adducts. Withmore » the combination of the selected antibody pair, several key parameters (such as the concentration of anti-BChE and anti-Pser, and the blocking agent) were optimized to enhance the sensitivity and selectivity of the sELISA. Under the optimal conditions, the sELISA has shown a wide linear range from 0.03 nM to 30 nM, with a detection limit of 0.03 nM. Furthermore, the sELISA was successfully applied to detect OP-BChE using in-vitro biological samples such as rat plasma spiked with OP-BChE with excellent adduct recovery (z>99 %). These results demonstrate that this novel approach holds great promise to develop an ELISA kit and offers a simple and cost-effective tool for screening/evaluating exposure to organophosphate insecticides and nerve agents.« less
Galvin, Pamela; Gildea, Sarah; Nelly, Maura; Quinlivan, Michelle; Arkins, Sean; Walsh, Cathal; Cullinane, Ann
2014-05-01
Equine influenza (EI) is a highly contagious respiratory disease of horses. The aim of this study was to evaluate two rapid antigen detection kits (Directigen or DFA, and Espline) and a commercial ELISA for the detection of EI nucleoprotein in nasal swabs. Nasal swab samples from naturally and experimentally infected horses were used to compare the sensitivity and specificity of these assays to virus isolation (VI) and real-time RT-PCR. If real-time RT-PCR was considered as the gold standard, the sensitivity of the other tests in field samples was 68% (DFA), 35% (ELISA), 29% (Espline), and 9% (VI). These tests had 100% specificity when compared to real-time RT-PCR. A receiver operating characteristic (ROC) curve indicated that decreasing the cutoff of the ELISA would increase sensitivity with some loss of specificity. In samples from experimentally infected horses, the sensitivity of the tests compared with real-time RT-PCR was 69% (VI), 27% (DFA), 6% (Espline), and 2% (ELISA). The specificity was 100% for Espline and ELISA and 95% for VI and DFA. This study illustrated that DFA is the most sensitive antigen detection test evaluated for the diagnosis of EI and that it can detect virus in some subclinical infected and vaccinated horses. The results suggest that DFA is a useful adjunct to laboratory tests and may be effective as a screening test in a quarantine station or similar facility where horses are monitored daily. © 2014 The Authors. Influenza and Other Respiratory Viruses Published by John Wiley & Sons Ltd.
Gutiérrez-Expósito, Daniel; Ortega-Mora, Luis Miguel; Ara, Victor; Marco, Ignasi; Lavín, Santiago; Carvajal-Valilla, Javier; Morales, Angel; Álvarez-García, Gema
2017-01-01
Besnoitia besnoiti and B. caprae, which infect bovids (cattle and antelopes) and goats, respectively, are responsible for besnoitiosis, a chronic and debilitating disease. Bovine besnoitiosis is considered to be a reemerging disease in Central and Western Europe. In addition, infection by Besnoitia spp. has been reported in reindeer from Sweden and Finland. Recently, the parasite was also detected in roe deer and red deer from Spain, where an interconnection between the domestic and sylvatic cycles of B. besnoiti has been presumed. In contrast, caprine besnoitiosis seems to be enzootic to Kenya and Iran. The presence of Besnoitia spp. in small domestic ruminants has never been explored in Europe, and the role that these species might play in the epidemiology of bovine besnoitiosis, as intermediate hosts or reservoirs of B. besnoiti, remains unknown. Herein, the first serosurvey conducted in European sheep and goats from areas in Spain where bovine besnoitiosis is endemic is described. Convenience sampling was conducted of 1943 sheep and 342 goats close to cattle from the Pyrenees and Central Spain that were infected with endemic Besnoitia spp. Serum samples were first analyzed by ELISA and then by confirmatory Western blot. Specific antibodies were not found in any sampled animal. Thus, sheep are unlikely to play a role in the epidemiology of bovine besnoitiosis, at least in the sampled areas. A larger serosurvey is necessary to determine whether goats might be a putative reservoir. To confirm the results of this study, sheep and goats should be further studied in other European countries and regions where their numbers are high and where bovine besnoitiosis is spreading.
Massebo, Fekadu; Balkew, Meshesha; Gebre-Michael, Teshome; Lindtjørn, Bernt
2015-12-18
Increased understanding of the feeding behaviours of malaria vectors is important to determine the frequency of human-vector contact and to implement effective vector control interventions. Here we assess the relative feeding preferences of Anopheles mosquitoes in relation to cattle and human host abundance in southwest Ethiopia. We collected female Anopheles mosquitoes bi-weekly using Centers for Disease Control and prevention (CDC) light traps, pyrethrum spray catches (PSCs) and by aspirating from artificial pit shelters, and determined mosquito blood meal origins using a direct enzyme-linked immunosorbent assay (ELISA). Both Anopheles arabiensis Patton and An. marshalli (Theobald) showed preference of bovine blood meal over humans regardless of higher human population sizes. The relative feeding preference of An. arabiensis on bovine blood meal was 4.7 times higher than that of human blood. Anopheles marshalli was 6 times more likely to feed on bovine blood meal than humans. The HBI of An. arabiensis and An. marshalli significantly varied between the collection methods, whereas the bovine feeding patterns was not substantially influenced by collection methods. Even though the highest HBI of An. arabiensis and An. marshalli was from indoor CDC traps collections, a substantial number of An. arabiensis (65%) and An. marshalli (63%) had contact with cattle. Anopheles arabiensis (44%) and An. marshalli (41%) had clearly taken bovine blood meals outdoors, but they rested indoors. Anopheles mosquitoes are zoophagic and mainly feed on bovine blood meals than humans. Hence, it is important to consider treatment of cattle with appropriate insecticide to control the zoophagic malaria vectors in southwest Ethiopia. Systemic insecticides like ivermectin and its member eprinomectin could be investigated to control the pyrethroid insecticides resistant vectors.
Fischer, Carrie D; Beatty, Jennifer K; Zvaigzne, Cheryl G; Morck, Douglas W; Lucas, Merlyn J; Buret, A G
2011-01-01
Clearance of apoptotic neutrophils is a central feature of the resolution of inflammation. Findings indicate that immuno-modulation and induction of neutrophil apoptosis by macrolide antibiotics generate anti-inflammatory benefits via mechanisms that remain obscure. Tulathromycin (TUL), a new antimicrobial agent for bovine respiratory disease, offers superior clinical efficacy for reasons not fully understood. The aim of this study was to identify the immuno-modulating effects of tulathromycin and, in this process, to establish tulathromycin as a new model for characterizing the novel anti-inflammatory properties of antibiotics. Bronchoalveolar lavage specimens were collected from Holstein calves 3 and 24 h postinfection, challenged intratracheally with live Mannheimia haemolytica (2 × 10(7) CFU), and treated with vehicle or tulathromycin (2.5 mg/kg body weight). Terminal deoxynucleotidyltransferase-mediated dUTP-biotin nick end labeling (TUNEL) staining and enzyme-linked immunosorbent assay (ELISA) revealed that tulathromycin treatment significantly increased leukocyte apoptosis and reduced levels of proinflammatory leukotriene B(4) in M. haemolytica-challenged calves. In vitro, tulathromycin concentration dependently induced apoptosis in freshly isolated bovine neutrophils from healthy steers in a capase-3-dependent manner but failed to induce apoptosis in bovine fibroblasts, epithelial cells, and endothelial cells, as well as freshly isolated bovine blood monocytes and monocyte-derived macrophages. The proapoptotic effects of TUL were also, in part, drug specific; equimolar concentrations of penicillin G, oxytetracycline, and ceftiofur failed to cause apoptosis in bovine neutrophils. In addition, tulathromycin significantly reduced levels of phosphorylated IκBα, nuclear translocation of NF-κB p65, and mRNA levels of proinflammatory interleukin-8 in lipopolysaccharide (LPS)-stimulated bovine neutrophils. The findings illustrate novel mechanisms through which tulathromycin confers anti-inflammatory benefits.
ACTIVATION OF PLATELET-RICH PLASMA USING SOLUBLE TYPE I COLLAGEN
Fufa, Duretti; Shealy, Blake; Jacobson, May; Kevy, Sherwin; Murray, Martha M.
2008-01-01
PURPOSE Platelet-rich plasma (PRP) has recently been found to be a useful delivery system for growth factors important in oral tissue healing. However, application of PRP in a liquid form to a wound site within the oral cavity can be complicated by significant loss of the PRP into the surrounding oral space unless gelation via the clotting mechanism is accomplished. Gelation is currently accomplished using bovine thrombin; however, rare but serious complications of this method have led to the search for alternative clotting mechanisms, including the use of soluble collagen as a clotting activator. In this paper, our hypothesis was that soluble Type I collagen would be as effective as bovine thrombin in causing clotting of the PRP and of stimulating growth factor release from the platelets and granulocytes. MATERIALS AND METHODS PRP from human donors was clotted using Type I collagen or bovine thrombin. Clot retraction was determined by measuring clot diameters over time. The release of PDGF-AB, TGF-β1 and VEGF from both types of clots was measured over 10 days using ELISA. RESULTS Clots formed using Type I collagen had far less retraction than those formed with bovine thrombin. Bovine thrombin and Type I collagen stimulated similar release of PDGF-AB and VEGF between 1 and 10 days; however, thrombin activation resulted in a greater release of TGF-β1 during the first five days after activation. CONCLUSIONS The use of Type I collagen to activate clotting of PRP may be a safe and effective alternative to bovine thrombin. The use of collagen results in less clot retraction and equal release of PDGF-AB and VEGF when compared to currently available methods of clot activation. PMID:18355591
Hernández-Mora, Gabriela; Ruiz-Villalobos, Nazareth; Bonilla-Montoya, Roberto; Romero-Zúniga, Juan-José; Jiménez-Arias, Julio; González-Barrientos, Rocío; Barquero-Calvo, Elías; Chacón-Díaz, Carlos; Rojas, Norman; Chaves-Olarte, Esteban; Guzmán-Verri, Caterina
2017-01-01
Brucellosis, caused by Brucella abortus is a major disease of cattle and a zoonosis. In order to estimate the bovine brucellosis prevalence in Costa Rica (CR), a total 765 herds (13078 bovines) from six regions of CR were randomly sampled during 2012–2013. A non-random sample of 7907 herds (532199 bovines) of the six regions, arriving for diagnoses during 2014–2016 to the Costa Rican Animal Health Service was also studied. The prevalence estimated by Rose Bengal test (RBT) ranged from 10.5%-11.4%; alternatively, the prevalence estimated by testing the RBT positives in iELISA, ranged from 4.1%-6.0%, respectively. However, cattle in CR are not vaccinated with B. abortus S19 but with RB51 (vaccination coverage close to 11%), and under these conditions the RBT displays 99% specificity and 99% sensitivity. Therefore, the RBT herd depicted in the random analysis stands as a feasible assessment and then, the recommended value in case of planning an eradication program in CR. Studies of three decades reveled that bovine brucellosis prevalence has increased in CR. B. abortus was identified by biochemical and molecular studies as the etiological agent of bovine brucellosis. Multiple locus variable-number tandem repeat analysis-16 revealed four B. abortus clusters. Cluster one and three are intertwined with isolates from other countries, while clusters two and four have only representatives from CR. Cluster one is widely distributed in all regions of the country and may be the primary B. abortus source. The other clusters seem to be restricted to specific areas in CR. The implications of our findings, in relation to the control of the disease in CR, are critically discussed. PMID:28797045
Hernández-Mora, Gabriela; Ruiz-Villalobos, Nazareth; Bonilla-Montoya, Roberto; Romero-Zúniga, Juan-José; Jiménez-Arias, Julio; González-Barrientos, Rocío; Barquero-Calvo, Elías; Chacón-Díaz, Carlos; Rojas, Norman; Chaves-Olarte, Esteban; Guzmán-Verri, Caterina; Moreno, Edgardo
2017-01-01
Brucellosis, caused by Brucella abortus is a major disease of cattle and a zoonosis. In order to estimate the bovine brucellosis prevalence in Costa Rica (CR), a total 765 herds (13078 bovines) from six regions of CR were randomly sampled during 2012-2013. A non-random sample of 7907 herds (532199 bovines) of the six regions, arriving for diagnoses during 2014-2016 to the Costa Rican Animal Health Service was also studied. The prevalence estimated by Rose Bengal test (RBT) ranged from 10.5%-11.4%; alternatively, the prevalence estimated by testing the RBT positives in iELISA, ranged from 4.1%-6.0%, respectively. However, cattle in CR are not vaccinated with B. abortus S19 but with RB51 (vaccination coverage close to 11%), and under these conditions the RBT displays 99% specificity and 99% sensitivity. Therefore, the RBT herd depicted in the random analysis stands as a feasible assessment and then, the recommended value in case of planning an eradication program in CR. Studies of three decades reveled that bovine brucellosis prevalence has increased in CR. B. abortus was identified by biochemical and molecular studies as the etiological agent of bovine brucellosis. Multiple locus variable-number tandem repeat analysis-16 revealed four B. abortus clusters. Cluster one and three are intertwined with isolates from other countries, while clusters two and four have only representatives from CR. Cluster one is widely distributed in all regions of the country and may be the primary B. abortus source. The other clusters seem to be restricted to specific areas in CR. The implications of our findings, in relation to the control of the disease in CR, are critically discussed.
A Quick and Parallel Analytical Method Based on Quantum Dots Labeling for ToRCH-Related Antibodies
NASA Astrophysics Data System (ADS)
Yang, Hao; Guo, Qing; He, Rong; Li, Ding; Zhang, Xueqing; Bao, Chenchen; Hu, Hengyao; Cui, Daxiang
2009-12-01
Quantum dot is a special kind of nanomaterial composed of periodic groups of II-VI, III-V or IV-VI materials. Their high quantum yield, broad absorption with narrow photoluminescence spectra and high resistance to photobleaching, make them become a promising labeling substance in biological analysis. Here, we report a quick and parallel analytical method based on quantum dots for ToRCH-related antibodies including Toxoplasma gondii, Rubella virus, Cytomegalovirus and Herpes simplex virus type 1 (HSV1) and 2 (HSV2). Firstly, we fabricated the microarrays with the five kinds of ToRCH-related antigens and used CdTe quantum dots to label secondary antibody and then analyzed 100 specimens of randomly selected clinical sera from obstetric outpatients. The currently prevalent enzyme-linked immunosorbent assay (ELISA) kits were considered as “golden standard” for comparison. The results show that the quantum dots labeling-based ToRCH microarrays have comparable sensitivity and specificity with ELISA. Besides, the microarrays hold distinct advantages over ELISA test format in detection time, cost, operation and signal stability. Validated by the clinical assay, our quantum dots-based ToRCH microarrays have great potential in the detection of ToRCH-related pathogens.
Martínez-Sernández, Victoria; Perteguer, María J; Hernández-González, Ana; Mezo, Mercedes; González-Warleta, Marta; Orbegozo-Medina, Ricardo A; Romarís, Fernanda; Paniagua, Esperanza; Gárate, Teresa; Ubeira, Florencio M
2018-05-01
Infections caused by Fasciola hepatica are of great importance in the veterinary field, as they cause important economic losses to livestock producers. Serodiagnostic methods, typically ELISA (with either native or recombinant antigens), are often used for early diagnosis. The use of native antigens, as in the MM3-SERO ELISA (commercialized as BIO K 211, BIO-X Diagnostics), continues to be beneficial in terms of sensitivity and specificity; however, there is interest in developing ELISA tests based on recombinant antigens to avoid the need to culture parasites. Of the antigens secreted by adult flukes, recombinant procathepsin L1 (rFhpCL1) is the most commonly tested in ELISA to date. However, although adult flukes produce three different clades of CLs (FhCL1, FhCL2, and FhCL5), to our knowledge, the diagnostic value of recombinant FhCL2 and FhCL5 has not yet been investigated. In the present study, we developed and tested three indirect ELISAs using rFhpCL1, rFhpCL2, and rFhpCL5 and evaluated their recognition by sera from sheep and cattle naturally infected with F. hepatica. Although the overall antibody response to these three rFhpCLs was similar, some animals displayed preferential recognition for particular rFhpCLs. Moreover, for cattle sera, the highest sensitivity was obtained using rFhpCL2 (97%), being equal for both rFhpCL1 and rFhpCL5 (87.9%), after adjusting cut-offs for maximum specificity. By contrast, for sheep sera, the sensitivity was 100% for the three rFhpCLs. Finally, the presence of truncated and/or partially unfolded molecules in antigen preparations is postulated as a possible source of cross-reactivity.
Khuda, Sefat E; Sharma, Girdhari M; Gaines, Dennis; Do, Andrew B; Pereira, Marion; Chang, Michael; Ferguson, Martine; Williams, Kristina M
2016-08-01
Since the number of recalls involving undeclared allergens is commonly associated with bakery and snack foods, we aimed to determine the frequency of egg allergens in a large number of these products using two commercial enzyme-linked immunosorbent assay (ELISA) methods. Samples were chosen that either had no egg identified on the product label or which had an egg precautionary statement. Among all samples, egg protein was detected in 5% of products using a Morinaga (MO) kit and 1% of products using a R-Biopharm (RB) kit. For bakery samples, egg protein was detected in 6% of 363 samples with no precautionary labelling (6% by MO and 1% by RB kit) and 12% of 80 samples which had precautionary labelling. For snack samples, egg protein was detected in 2% of 371 samples with no precautionary labelling (2% by MO and < 1% by RB kit) and 5% of 21 samples which had precautionary labelling. The disagreement rates between two methods were 5.2% for bakery products and 2.6% for snack products. The sample repeatability was at an acceptable level for bakery (< 12.5%) and snack foods (< 7.5%) for each method. The relative standard deviation between test kits was high (103.1%) for bakery foods. Four bakery products without precautionary labelling had a higher level of egg protein per serving compared with the eliciting dose (ED10 of 3.7 mg protein) for egg allergic patients. These results highlight the fact that detection methodology plays a vital role for accurate labelling control and mitigation of risk for egg allergic consumers.
The Role of Stat3 Activation in Androgen Receptor Signaling and Prostate Cancer
2005-07-01
METHODS InVitro Growth Assay Tissue Culture DU145, PC3, and LN-17 cells ( 1 x 105 per well) were plated in 12-well plates in RPMI containing 10% FBS. Human...specific ELISA kit. 1 ] LNSI Parental LNCaP, neo, and IL- # OLN-S17 6 overexpressing (LN-S15 c 0.8 - and LN-S17) cells were 0e cultured in either...independence [1,2]. Stat3, a member of Janus Shadyside Medical Center, Suite G03, 5200 Centre Avenue, Kinase (JAK)-Signal Transducers and Activators of
Maluping, Ramon P; Oronan, Rey B; Toledo, Steven U
2007-01-01
The present study was undertaken to detect the presence of Chlamydophila psittaci antibodies in captive birds at the Wildlife Rescue Center, Ninoy Aquino Parks and Wildlife Nature Center, Quezon City, Philippines. Blood was collected from 36 birds of different species and the presence of antibodies against C. psittaci was detected using an ELISA-based test kit. 25% of the samples demonstrated antibodies against C. psittaci. The results of this study confirmed the presence of C. psittaci antibodies among the captive birds examined.
Reinbold, James B.; Coetzee, Johann F.; Sirigireddy, Kamesh R.; Ganta, Roman R.
2010-01-01
Insufficient diagnostic sensitivity and specificity coupled with the potential for cross-reactivity among closely related Anaplasma species has made the accurate determination of infection status problematic. A method for the development of simplex and duplex real-time quantitative reverse transcriptase PCR (qRT-PCR) assays for the detection of A. marginale and A. phagocytophilum 16S rRNA in plasma-free bovine peripheral blood samples is described. The duplex assay was able to detect as few as 100 copies of 16S rRNA of both A. marginale and A. phagocytophilum in the same reaction. The ratio of 16S rRNA to 16S DNA copies for A. marginale was determined to be 117.9:1 (95% confidence interval [95% CI], 100.7:1, 135.2:1). Therefore, the detection limit is the minimum infective unit of one A. marginale bacterium. The duplex assay detected nonequivalent molar ratios as high as 100-fold. Additionally, the duplex assay and a competitive enzyme-linked immunosorbent assay (cELISA) were used to screen 237 samples collected from herds in which anaplasmosis was endemic. When the cELISA was evaluated by the results of the qRT-PCR, its sensitivity and specificity for the detection of A. marginale infection were found to be 65.2% (95% CI, 55.3%, 75.1%) and 97.3% (95% CI, 94.7%, 99.9%), respectively. A. phagocytophilum infection was not detected in the samples analyzed. One- and two-way receiver operator characteristic curves were constructed in order to recommend the optimum negative cutoff value for the cELISA. Percentages of inhibition of 20 and 15.3% were recommended for the one- and two-way curves, respectively. In conclusion, the duplex real-time qRT-PCR assay is a highly sensitive and specific diagnostic tool for the accurate and precise detection of A. marginale and A. phagocytophilum infections in cattle. PMID:20463162
Wawegama, Nadeeka K.; Kanci, Anna; Marenda, Marc S.; Markham, Philip F.
2014-01-01
Mycoplasma bovis causes a range of diseases in cattle, including mastitis, arthritis, and pneumonia. However, accurate serological diagnosis of infection remains problematic. The studies described here aimed to identify an antigen that might be used to develop a more specific and sensitive diagnostic assay. A 226-kDa immunogenic protein was consistently detected in Western blots by antibodies in sera from calves experimentally infected with M. bovis. This protein was shown to be a membrane protein with lipase activity and was named mycoplasma immunogenic lipase A (MilA). Different regions of MilA were expressed in Escherichia coli as glutathione S-transferase (GST) fusion proteins and recombinant products from the amino-terminal end shown to have strong immunoreactivity with M. bovis-specific bovine sera. The most immunoreactive fusion protein, GST-MilA-ab, was used to develop indirect IgM and IgG enzyme-linked immunosorbent assays (ELISAs). The IgM ELISA detected M. bovis-specific IgM antibody 2 weeks after infection with 97.1% sensitivity and had a specificity of 63.3%, while the IgG ELISA detected M. bovis-specific IgG 3 weeks after infection with 92.86% sensitivity and had a specificity of 98.7%, demonstrating that the IgG ELISA has potential for use as a sensitive and specific assay for detecting infection in cattle. PMID:24334686
Chakraborty, A K; Karam, A; Mukherjee, P; Barkalita, L; Borah, P; Das, S; Sanjukta, R; Puro, K; Ghatak, S; Shakuntala, I; Sharma, I; Laha, R G; Sen, A
2018-03-01
The present study focused on the detection and genetic characterisation of 5' untranslated region (5'UTR) and E2 gene of classical swine fever virus (CSFV, family Flaviviridae , genus Pestivirus ) from bovine population of the northeastern region of India. A total of 134 cattle serum samples were collected from organised cattle farms and were screened for CSFV antigen with a commercial antigen capture enzyme linked immunosorbent assay (Ag-ELISA) and reverse transcription-polymerase chain reaction (RT-PCR). A total of 10 samples were positive for CSFV antigen by ELISA, while all of them were positive in PCR for 5'UTR region. Full length E2 region of CSFV were successfully amplified from two positive samples and used for subsequent phylogenetic analysis and determination of protein 3D structure which showed similarity with reported CSFV isolate from Assam of sub-genogroup 2.1, with minor variations in protein structure.
Schack, L; Lange, A; Kelsen, J; Agnholt, J; Christensen, B; Petersen, T E; Sørensen, E S
2009-11-01
Osteopontin (OPN) is a multifunctional bioactive protein that is implicated in numerous biological processes such as bone remodeling, inhibition of ectopic calcification, and cellular adhesion and migration, as well as several immune functions. Osteopontin has cytokine-like properties and is a key factor in the initiation of T helper 1 immune responses. Osteopontin is present in most tissues and body fluids, with the highest concentrations being found in milk. In the present study, ELISA for human and bovine milk OPN were developed and OPN concentration in human breast milk, bovine milk, and infant formulas was measured and compared. The OPN concentration in human milk was measured to approximately 138 mg/L, which corresponds to 2.1% (wt/wt) of the total protein in human breast milk. This is considerably higher than the corresponding OPN concentrations in bovine milk (approximately 18 mg/L) and infant formulas (approximately 9 mg/L). Moreover, bovine milk OPN is shown to induce the expression of the T helper 1 cytokine IL-12 in cultured human lamina propria mononuclear cells isolated from intestinal biopsies. Finally, the OPN concentration in plasma samples from umbilical cords, 3-mo-old infants, and pregnant and nonpregnant adults was measured. The OPN level in plasma from 3-mo-old infants and umbilical cords was found to be 7 to 10 times higher than in adults. Thus, the high levels of OPN in milk and infant plasma suggest that OPN is important to infants and that ingested milk OPN is likely to induce cytokine production in neonate intestinal immune cells.
Association between bovine casein antibody and new onset schizophrenia among US military personnel.
Niebuhr, David W; Li, Yuanzhang; Cowan, David N; Weber, Natalya S; Fisher, Jared A; Ford, Glen M; Yolken, Robert
2011-05-01
Schizophrenia is a pervasive neuropsychiatric disorder of uncertain etiology. Multiple studies have documented immune activation in individuals with schizophrenia. One antigen capable of inducing a prolonged immune response is bovine casein derived from ingested milk products. Increased levels of casein antibodies have been found in individuals with schizophrenia after diagnosis. This study was directed at determining the potential association between schizophrenia and pre-illness onset levels of immunoglobulin G (IgG) antibodies to bovine casein. Parallel analyses for casein antibody levels with bipolar disorder were included as comparison. Cases were service members who received medical discharges from the military with a schizophrenia diagnosis from 1992 to 2005. Serum specimens were selected for 855 cases and 1165 matched healthy controls. IgG antibodies to bovine whole-casein were measured by solid phase enzyme-linked immunosorbent assays (ELISAs). Hazard ratios (HR) were calculated to examine the associations of casein IgG level with risk of schizophrenia by time to diagnosis and by subjects' initial level. Increasing casein IgG antibody levels among those with a high initial level, drawn before diagnosis, was associated with an 18% increase in the hazard risk of schizophrenia per unit increase (value of low-positive standard) in IgG antibody levels (HR=1.18; 95% CI 1.04, 1.34). This is the first report to identify an association between the risk of schizophrenia and elevated antibodies to bovine casein prior to disease onset. Additional research is required to elucidate the complex genetic environmental interactions involved in the pathogenesis of schizophrenia and to identify potentially modifiable risk factors. Published by Elsevier B.V.
Persistent Seroconversion after Accidental Eye Exposure to Calcifying Nanoparticles
NASA Technical Reports Server (NTRS)
Ciftcioglu, Neva; Aho, Katja M.; McKay, David S.; Kajander, E. Olavi
2007-01-01
Biosafety of nanomaterials has attracted much attention recently. We report here a case where accidental human eye exposure to biogenic nanosized calcium phosphate in the form of calcifying nanoparticles (CNP) raised a strong IgG immune response against proteins carried by CNP. The antibody titer has persisted over ten years at the high level. The IgG was detected by ELISA using CNPs propagated in media containing bovine and human serum as antigen. The exposure incident occurred to a woman scientist (WS) at a research laboratory in Finland at 1993. CNP, also termed "nanobacteria", is a unique self-replicating agent that has not been fully characterized and no data on biohazards were available at that time. Before the accident, her serum samples were negative for both CNP antigen and anti-CNP antibody using specific ELISA tests (Nanobac Oy, Kuopio, Finland). The accident occurred while WS was harvesting CNP cultures. Due to a high pressure in pipetting, CNP pellet splashed into her right eye. Both eyes were immediately washed with water and saline. The following days there was irritation and redness in the right eye. These symptoms disappeared within two weeks without any treatment. Three months after the accident, blood and urine samples of WS were tested for CNP cultures (2), CNP-specific ELISA tests, and blood cell counts. Blood cell counts were normal, CNP antigen and culture tests were negative. A high IgG anti-CNP antibody titer was detected (see Figure). The antibodies of this person have been used thereafter as positive control and standard in ELISA manufacturing (Nano-Sero IgG ELISA, Nanobac Oy, Kuopio, Finland).
Bingham, P C; McFadden, A M J; Wang, J; Kittelberger, R; Clough, R R; Tham, K M
2010-10-01
To investigate the cause of classical swine fever (CSF) virus-seropositive animals in a nucleus pig-breeding herd in New Zealand, where porcine circovirus-associated disease had been diagnosed. An exotic disease investigation was undertaken to exclude CSF and porcine reproductive and respiratory syndrome (PRRS) on a nucleus pig-breeding herd comprising approximately 300 breeding sows, 1,000 weaners, and 650 grower pigs. The herd was experiencing poor reproductive performance in sows, and breeding records showed a declining farrowing rate attributable to a single manager. The growing pigs (10-15 weeks old) were experiencing respiratory disease and wasting, and the mortality rate by pen varied between 9 and 20%. Post-mortem changes in affected grower pigs were consistent with circovirus-associated diseases. DIAGNOSTIC TESTING: Serological screening using an IDEXX-ELISA gave negative results for PRRS virus antibodies, but two grower pigs and one sow tested positive for CSF virus antibodies. These three seropositive animals remained positive to CSF virus, using three commercial ELISA test kits, over 27 weeks. A newly developed virus neutralisation test (VNT), using a New Zealand isolate of border disease (BD) virus, demonstrated that the seropositive pig sera had higher antibody titres to BD virus than to bovine viral diarrhoea (BVD) virus and CSF virus. PCR performed on tonsil, kidney, ileum and spleen gave negative results for CSF virus, and histopathology on lymph nodes, intestine, lung, kidney, liver and brain showed no evidence of the disease. Virus isolation performed on a number of samples was negative. The seropositive samples for CSF virus found in this investigation were likely to be a cross reaction to a pestivirus other than CSF virus. The finding of a possible endemic pestivirus capable of being transmitted between sheep and pigs on this farm may explain findings from previous serological survey work in New Zealand, and supports experience elsewhere, where BD virus was found to be the predominant ruminant pestivirus infecting pigs. The results show that pestivirus cross reactivity can result in unexpectedly high titres, and that testing with a full set of (local) pestiviruses is necessary to reach the correct conclusion. The investigation has direct relevance where pig herds with a low seroprevalence are encountered during surveillance for CSF.
Proteoglycan 4 (PRG4) synthesis and immunolocalization in bovine meniscus.
Schumacher, Barbara L; Schmidt, Tannin A; Voegtline, Michael S; Chen, Albert C; Sah, Robert L
2005-05-01
Proteoglycan 4 (PRG4) is synthesized and secreted into the synovial fluid by articular chondrocytes and synovial cells, lining the cavity of joints. A thin layer of PRG4 is also present at the articular surface, where it appears to be involved in boundary lubrication. This study investigated if PRG4 is also synthesized and secreted by the cells within meniscus, and if PRG4 is also present in, and at the surface of, meniscus. PRG4 was visualized in sections of bovine calf menisci by immunohistochemistry. PRG4 was detected in two regions: (1) at the femoral and tibial surfaces of the meniscus, and within cells below these surfaces; and (2) within and near cells along the radial tie fibers and circumferential fibers. From meniscus tissue harvested from these surfaces, PRG4 was extracted with 4M GuHCl and quantified by ELISA. There was 0.20 +/- 0.01 and 0.25 +/- 0.04 microg PRG4/cm(2) area of lateral and medial meniscus surface, respectively. ELISA analysis of spent medium from other samples of meniscus surface tissue incubated in medium supplemented with serum and ascorbate showed that 8.1 +/- 1.1 microg PRG4/cm(2) area of meniscus surface was secreted over six days. These results demonstrate that PRG4 is synthesized and secreted by certain cell populations in the meniscus, and that PRG4 is present in the meniscus at surfaces and also internal fibers where it may contribute to boundary lubrication.
Singh, Gurmit; Koerner, Terence; Gelinas, Jean-Marc; Abbott, Michael; Brady, Beth; Huet, Anne-Catherine; Charlier, Caroline; Delahaut, Philippe; Godefroy, Samuel Benrejeb
2011-01-01
Malachite green (MG), a member of the N-methylated triphenylmethane class of dyes, has long been used to control fungal and protozoan infections in fish. MG is easily absorbed by fish during waterborne exposure and is rapidly metabolized into leucomalachite green (LMG), which is known for its long residence time in edible fish tissue. This paper describes the development of an enzyme-linked immunosorbent assay (ELISA) for the detection and quantification of LMG in fish tissue. This development includes a simple and versatile method for the conversion of LMG to monodesmethyl-LMG, which is then conjugated to bovine serum albumin (BSA) to produce an immunogenic material. Rabbit polyclonal antibodies are generated against this immunogen, purified and used to develop a direct competitive enzyme-linked immunosorbent assay (ELISA) for the screening and quantification of LMG in fish tissue. The assay performed well, with a limit of detection (LOD) and limit of quantification (LOQ) of 0.1 and 0.3 ng g−1 of fish tissue, respectively. The average extraction efficiency from a matrix of tilapia fillets was approximately 73% and the day-to-day reproducibility for these extractions in the assay was between 5 and 10%. PMID:21623496
Wongtangprasert, Tossapon; Natakuathung, Wirongrong; Pimpitak, Umaporn; Buakeaw, Anumart; Palaga, Tanapat; Komolpis, Kittinan; Khongchareonporn, Nanthika
2014-01-01
A novel monoclonal antibody (MAb) against oxytetracycline (OTC) was generated and characterized. The MAb was used in the development of an enzyme-linked immunosorbant assay (ELISA)-based detection system. An OTC-bovine serum albumin (BSA) conjugate was prepared and used in the immunization of mice. A conventional somatic cell fusion technique was used to generate MAb-secreting hybridomas denoted 2-4F, 7-3G, and 11-11A. An indirect competitive ELISA (icELISA) was applied to measure the sensitivity and specificity of each MAb in terms of its 50% inhibitory concentration (IC50) and percentage of cross-reactivity, respectively. MAb 2-4F exhibited the highest sensitivity, with an IC50 of 7.01 ng/ml. This MAb showed strong cross-reactivity to rolitetracycline, but no cross-reactivity to other unrelated antibiotics. When MAb 2-4F was used to detect OTC from shrimp samples, the recoveries were in the range of 82%–118% for an intra-assay and 96%–113% for an inter-assay. The coefficients of variation of the assays were 3.9%–13.9% and 5.5%–14.9%, respectively. PMID:24510709
Sun, Wenjie; Luna-Velasco, Antonia; Sierra-Alvarez, Reyes; Field, Jim A
2013-03-01
Growth in the nanotechnology industry is leading to increased production of engineered nanoparticles (NPs). This has given rise to concerns about the potential adverse and toxic effects to biological system and the environment. An important mechanism of NP toxicity is oxidative stress caused by the formation of reactive oxygen species (ROS) or via direct oxidation of biomolecules. In this study, a protein oxidation assay was developed as an indicator of biomolecule oxidation by NPs. The oxidation of the protein, bovine serum albumin (BSA) was evaluated with an enzyme-linked immunosorbent assay (ELISA) to measure the protein carbonyl derivatives formed from protein oxidation. The results showed that some NPs such as Cu(0), CuO, Mn(2)O(3), and Fe(0) caused oxidation of BSA; whereas, many of the other NPs tested were not reactive or very slowly reactive with BSA. The mechanisms involved in the oxidation of BSA protein by the reactive NPs could be attributed to the combined effects of ROS-dependent and direct protein oxidation mechanisms. The ELISA assay is a promising method for the assessment of protein oxidation by NPs, which can provide insights on NP toxicity mechanisms. Copyright © 2012 Wiley Periodicals, Inc.
TECHNOLOGIES FOR MONITORING AND MEASUREMENT ...
A demonstration of technologies for determining the presence of dioxin and dioxin-like compounds in soil and sediment was conducted under EPA's Superfund Innovative Technology Evaluation Program in Saginaw, Michigan in April 2004. This report describes the performance evaluation of the Abraxis LLC Coplanar PCB Enzyme-Linked Immunosorbent Assay (ELISA) kit. The kit is an immunoassay technique that reports the total toxicity equivalents (TEQ) of polychlorinated biphenyls (PCBs). The technology results were compared to high resolution mass spectrometry TEQ results generated using EPA Method 1668A.Abraxis generally reported data that were higher than the reference laboratory TEQPCB values, with the exception of ultra-high level PCB samples [> 10,000 picogram/gram (pg/g) TEQ] where Abraxis reported values lower than the reference method. The technologys estimated MDL was 6 to 31 pg/g TEQPCB. Results from this demonstration suggest that the Abraxis kit could be an effective screening tool for screening sample concentrations above and below 50 pg/g TEQPCB, particularly considering that the cost ($22,668 vs. $184,449) and the time to analyze the 209 demonstration samples were significantly less than those of the reference laboratory. The objective of this program is to promote the acceptance and use of innovative field technologies by providing well-documented performance and cost data obtained from field demonstrations.
Oliveira, T C; Santos, A B R; Rabelo, K C N; Souza, C A; Santos, S M; Crovella, S
2016-11-03
The use of insects to answer questions in criminal investigations, as well as a combination of forensic genetic techniques to obtain human DNA from the organisms, especially necrophagous dipterians, have gained ground in recent decades among researchers and professionals in this area. The objective of our study was to evaluate and compare two methods of human DNA extraction, commonly used for forensic samples, to obtain human autosomal DNA and X chromosome short tandem repeat profiles from the digestive tract of Chrysomya albiceps (Diptera: Calliphoridae) larvae. Immature specimens were collected from corpses at the Institute of Forensic Medicine of Pernambuco and raised in bovine ground meat to allow stabilization of the colony. Groups of larvae in the third instar were provided with bovine ground meat plus human blood for 48 h, dissected, and then subjected to DNA extraction. DNA was extracted using two methods: a DNA IQ™ kit and a phenol-chloroform method. Genomic DNA was amplified using AmpFℓSTR ® Identifiler ® Plus PCR and Argus-X-12 ® kits, and samples were sequenced to determine if the two extraction techniques generated reliable profiles that were compatible with a reference sample. The existence of comparable profiles from both techniques demonstrates the usefulness of dipteran larvae for obtaining human DNA from corpses, which can be further used to correlate genetic profiles in a crime scene when other traces are not available. However, several variables still require revision; thus, the technique should be further investigated for its validity, security, and, in particular, its reproducibility.
Detection of pregnancy in sheep using an ELISA for pregnancy-specific protein B.
Milisits-Németh, Tímea; Balogh, Orsolya Gabriella; Egerszegi, István; Kern, László; Sasser, R Garth; Gábor, György
2018-06-01
The early detection of pregnancy and the determination of fetal numbers have economic benefits in sheep production because of the seasonal breeding patterns where missing a breeding opportunity means the loss of one productive year. The purpose of this study was to evaluate the efficacy of the B6-HRP ELISA for ovine pregnancy-specific protein B (oPSPB) measurement in the detection of pregnancy and estimation of fetal numbers in different sheep breeds. BioPRYN® ELISA assay kit was used for the detection of pregnancy in the experimental animals. Ninety-three ewes of three breeds (British Milksheep - BM, Lacaune - L and Transylvanian Racka - TR), each from three farms in Hungary, were included in the study. BM and L ewes were artificially inseminated (AI). Thirty-five days after AI, all ewes were examined by transabdominal ultrasound. The TR flock was mated naturally over a six-week period. At the end of the mating period, the ewes were similarly examined by ultrasound. Blood samples were taken from all pregnant ewes twice (35 and 65 days after AI), and serum samples were assayed by the BioPRYN test. It can be concluded that the detection of serum PSPB by ELISA is a much easier, safer, less expensive and highly accurate method for the detection of ovine pregnancy. Although some breed-related differences were detectable at 35 and 65 days post breeding, no differences in oPSPB levels were found in pregnant ewes carrying different numbers of fetuses.
Liu, Jian; Chen, Chunye; Zhu, Rui; Ye, Xiangzhong; Jia, Jizong; Yang, Lianwei; Wang, Yongmei; Wang, Wei; Ye, Jianghui; Li, Yimin; Zhu, Hua; Zhao, Qinjian; Zhang, Jun; Cheng, Tong; Xia, Ningshao
2016-11-01
Varicella is a highly contagious disease caused by primary infection of Varicella zoster virus (VZV). Varicella can be severe or even lethal in susceptible adults, immunocompromised patients and neonates. Determination of the status of immunity to VZV is recommended for these high-risk populations. Furthermore, measurement of population immunity to VZV can help in developing proper varicella vaccination programmes. VZV glycoprotein E (gE) is an antigen that has been demonstrated to be a highly accurate indicator of VZV-specific immunity. In this study, recombinant gE (rgE) was used to establish a double antigen sandwich enzyme-linked immunosorbent assay (ELISA). The established sandwich ELISA showed high specificity and sensitivity in the detection of human sera, and it could detect VZV-specific antibodies at a concentration of 11.25 m IU/mL with a detection linearity interval of 11.25 to 360 m IU/mL (R 2 = 0.9985). The double gE antigen sandwich ELISA showed a sensitivity of 95.08 % and specificity of 100 % compared to the fluorescent-antibody-to-membrane-antigen (FAMA) test, and it showed a sensitivity of 100 % and a specificity of 94.74 % compared to a commercial neutralizing antibody detection kit. Thus, the established double antigen sandwich ELISA can be used as a sensitive and specific quantitative method to evaluate immunity to VZV.
Parma, Y. R.; Chacana, P. A.; Lucchesi, P. M. A.; Rogé, A.; Granobles Velandia, C. V.; Krüger, A.; Parma, A. E.; Fernández-Miyakawa, M. E.
2012-01-01
Enterohemorrhagic Escherichia coli (EHEC), a subset of Shiga toxin producing E. coli (STEC) is associated with a spectrum of diseases that includes diarrhea, hemorrhagic colitis and a life-threatening hemolytic-uremic syndrome (HUS). Regardless of serotype, Shiga toxins (Stx1 and/or Stx2) are uniformly expressed by all EHEC, and so exploitable targets for laboratory diagnosis of these pathogens. In this study, a sandwich ELISA for determination of Shiga toxin (Stx) was developed using anti-Stx2B subunit antibodies and its performance was compared with that of the Vero cell assay and a commercial immunoassay kit. Chicken IgY was used as capture antibody and a HRP-conjugated rabbit IgG as the detection antibody. The anti-Stx2B IgY was harvested from eggs laid by hens immunized with a recombinant protein fragment. Several parameters were tested in order to optimize the sandwich ELISA assay, including concentration of antibodies, type and concentration of blocking agent, and incubation temperatures. Supernatants from 42 STEC strains of different serotypes and stx variants, including stx2EDL933, stx2vha, stx2vhb, stx2g, stx1EDL933, and stx1d were tested. All Stx variants were detected by the sandwich ELISA, with a detection limit of 115 ng/ml Stx2. Twenty three strains negative for stx genes, including different bacteria species, showed no activity in Vero cell assay and produced negative results in ELISA, except for two strains. Our results show that anti-Stx2B IgY sandwich ELISA could be used in routine diagnosis as a rapid, specific and economic method for detection of Shiga toxin-producing E. coli. PMID:22919675
Marché, Sylvie; Houdart, Philippe; van den Berg, Thierry; Lambrecht, Bénédicte
2016-05-01
Surveillance of notifiable avian influenza (NAI) virus is mandatory in European member states, and each year a serological survey is performed to detect H5 and H7 circulation in poultry holdings. In Belgium, this serological monitoring is a combination of a stratified and a risk-based approach and is applied to commercial holdings with more than 200 birds. Moreover, a competitive nucleoprotein (NP) ELISA has been used as first screening method since 2010. A retrospective analysis of the serological monitoring performed from 2007 through 2013 showed sporadic circulation of notifiable low-pathogenicity avian influenza (LPAI) viruses in Belgian holdings with a fluctuating apparent flock seroprevalence according to years and species. Overall, the highest apparent flock seroprevalence was detected for the H5 subtype in domestic Anatidae, with 20%-50% for breeding geese and 4%-9% for fattening ducks. Positive serology against non-H5/H7 viruses was also observed in the same species with the use of the IDScreen influenza A antibody competition ELISA kit (ID-vet NP ELISA), and confirmed by isolation of H2, H3, H6, and H9 LPAI viruses. Among Galliformes, the apparent flock seroprevalence was lower, ranging between 0.3% and 1.3%. Circulation of notifiable LPAI viruses was only observed in laying hens with a similar seroprevalence for H5 and H7. Based on ID-vet NP ELISA results, no circulation of LPAI viruses, regardless the subtype, was observed in breeding chickens and fattening turkeys. Retrospectively, the use of an ELISA as first-line test not only reduced the number of hemagglutination inhibition tests to be performed, but also gave a broader evaluation of the prevalence of LPAI viruses in general, and might help to identify the most at-risk farms.
Marché, Sylvie; Houdart, Philippe; van den Berg, Thierry; Lambrecht, Bénédicte
2015-12-01
Surveillance of notifiable avian influenza (NAI) virus is mandatory in European member states, and each year a serological survey is performed to detect H5 and H7 circulation in poultry holdings. In Belgium, this serological monitoring is a combination of a stratified and a risk-based approach and is applied to commercial holdings with more than 200 birds. Moreover, a competitive nucleoprotein (NP) ELISA has been used as first screening method since 2010. A retrospective analysis of the serological monitoring performed from 2007 through 2013 showed sporadic circulation of notifiable low-pathogenicity avian influenza (LPAI) viruses in Belgian holdings with a fluctuating apparent flock seroprevalence according to years and species. Overall, the highest apparent flock seroprevalence was detected for the H5 subtype in domestic Anatidae, with 20%-50% for breeding geese and 4%-9% for fattening ducks. Positive serology against non-H5/H7 viruses was also observed in the same species with the use of the IDScreen influenza A antibody competition ELISA kit (ID-vet NP ELISA), and confirmed by isolation of H2, H3, H6, and H9 LPAI viruses. Among Galliformes, the apparent flock seroprevalence was lower, ranging between 0.3% and 1.3%. Circulation of notifiable LPAI viruses was only observed in laying hens with a similar seroprevalence for H5 and H7. Based on ID-vet NP ELISA results, no circulation of LPAI viruses, regardless the subtype, was observed in breeding chickens and fattening turkeys. Retrospectively, the use of an ELISA as first-line test not only reduced the number of hemagglutination inhibition tests to be performed, but also gave a broader evaluation of the prevalence of LPAI viruses in general, and might help to identify the most at-risk farms.
Chung, Chungwon J; Clavijo, Alfonso; Bounpheng, Mangkey A; Uddowla, Sabena; Sayed, Abu; Dancho, Brooke; Olesen, Ian C; Pacheco, Juan; Kamicker, Barbara J; Brake, David A; Bandaranayaka-Mudiyanselage, Carey L; Lee, Stephen S; Rai, Devendra K; Rieder, Elizabeth
2018-06-01
The highly contagious foot-and-mouth disease virus (FMDV) afflicts cloven-hoofed animals, resulting in significant costs because of loss of trade and recovery from disease. We developed a sensitive, specific, and rapid competitive ELISA (cELISA) to detect serum antibodies to FMDV. The cELISA utilized a monoclonal blocking antibody specific for a highly conserved FMDV nonstructural 3B epitope, a recombinant mutant FMDV 3ABC coating protein, and optimized format variables including serum incubation for 90 min at 20-25°C. Samples from 16 animals experimentally infected with one FMDV serotype (A, O, Asia, or SAT-1) demonstrated early detection capacity beginning 7 d post-inoculation. All samples from 55 vesicular stomatitis virus antibody-positive cattle and 44 samples from cloven-hoofed animals affected by non-FMD vesicular diseases were negative in the cELISA, demonstrating 100% analytical specificity. The diagnostic sensitivity was 100% against sera from 128 cattle infected with isolates of all FMDV serotypes, emphasizing serotype-agnostic results. Diagnostic specificities of U.S. cattle ( n = 1135) and swine ( n = 207) sera were 99.4% and 100%, respectively. High repeatability and reproducibility were demonstrated with 3.1% coefficient of variation in percent inhibition data and 100% agreement using 2 kit lots and 400 negative control serum samples, with no difference between bench and biosafety cabinet operation. Negative results from vaccinated, uninfected cattle, pig, and sheep sera confirmed the DIVA (differentiate infected from vaccinated animals) capability. This rapid (<3 h), select agent-free assay with high sensitivity and specificity, DIVA capability, and room temperature processing capability will serve as a useful tool in FMDV surveillance, emergency preparedness, response, and outbreak recovery programs.
Wu, Yunqing; Zeng, Lifeng; Xiong, Ying; Leng, Yuankui; Wang, Hui; Xiong, Yonghua
2018-05-01
Herein, we present a novel sandwich fluorescence enzyme linked immunosorbent assay (ELISA) for highly sensitive detection of Hepatitis B virus surface antigen (HBsAg) based on glucose oxidase (GOx)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (MPA-QDs). In this system, hydrogen peroxide (H 2 O 2 ) sensitive MPA-QDs was used as a signal output, and glucose oxidase (GOx) was used as label which can generate H 2 O 2 via catalytic oxidation of glucose. The proposed method showed dynamic linear detection of HBsAg both in the range of 47pgmL -1 ~ 380pgmL -1 and 0.75ngmL -1 ~ 12.12ngmL -1 . The detection limit of the proposed fluorescence ELISA was 1.16pgmL -1 , which was approximately 430-fold lower than that of horseradish peroxidase (HRP)-based conventional ELISA. The average recoveries for HBsAg-spiked serum samples ranged from 98.0% to 126.8% with the relative standard derivation below 10%, thus indicating acceptable precision and high reproducibility of the proposed fluorescence ELISA for HBsAg detection. Additionally, the developed method showed no false positive results analyzing 35 real HBsAg-negative serum samples, and exhibited excellent agreement (R 2 =0.9907) with a commercial time-resolved fluorescence immunoassay (TRFIA) kit for detecting 31 HBsAg-positive serum samples. In summary, the proposed method based on fluorescence quenching of H 2 O 2 sensitive QDs is considerably to be an excellent biodetection platform with ultrahigh sensitivity, good accuracy and excellent reliability. Copyright © 2018 Elsevier B.V. All rights reserved.
Caballero-Ortega, Heriberto; Castillo-Cruz, Rocío; Murieta, Sandra; Ortíz-Alegría, Luz Belinda; Calderón-Segura, Esther; Conde-Glez, Carlos J; Cañedo-Solares, Irma; Correa, Dolores
2014-05-14
There are few articles on evaluation of Toxoplasma gondii serological tests. Besides, commercially available tests are not always useful and are expensive for studies in open population. The aim of this study was to evaluate in-house ELISA and western blot for IgG antibodies in a representative sample of people living in Mexico. Three hundred and five serum samples were randomly selected from two national seroepidemiological survey banks; they were taken from men and women of all ages and from all areas of the country. ELISA cut-off was established using the mean plus three standard deviations of negative samples. Western blots were analysed by two experienced technicians and positivity was established according to the presence of at least three diagnostic bands. A commercial ELISA kit was used as a third test. Two reference standards were built up: one using concordant results of two assays leaving the evaluated test out and the other in which the evaluated test was included (IN) with at least two concordant results to define diagnosis. the lowest values of diagnostic parameters were obtained with the OUT reference standards: in-house ELISA had 96.9% sensitivity, 62.1% specificity, 49.6% PPV, 98.1% NPV and 71.8% accuracy, while western blot presented 81.8%, 89.7%, 84.0%, 88.2% and 86.6% values and the best kappa coefficient (0.72-0.82). The in-house ELISA is useful for screening people of Mexico, due to its high sensitivity, while western blot may be used to confirm diagnosis. These techniques might prove useful in other Latin American countries.
John, Emily E; Nekouei, Omid; McClure, J T; Cameron, Marguerite; Keefe, Greg; Stryhn, Henrik
2018-06-01
Bulk tank milk (BTM) samples are used to determine the infection status and estimate dairy herd prevalence for bovine leukaemia virus (BLV) using an antibody ELISA assay. BLV ELISA variability between samples from the same herd or from different herds has not been investigated over long time periods. The main objective of this study was to determine the within-herd and between-herd variability of a BTM BLV ELISA assay over 1-month, 3-month, and 3-year sampling intervals. All of the Canadian Maritime region dairy herds (n = 523) that were active in 2013 and 2016 were included (83.9% and 86.9% of total herds in 2013 and 2016, respectively). BLV antibody levels were measured in three BTM samples collected at 1-month intervals in early 2013 as well as two BTM samples collected over a 3-month interval in early 2016. Random-effects models, with fixed effects for sample replicate and province and random effects for herd, were used to estimate the variability between BTM samples from the same herd and between herds for 1-month, 3-month, and 3-year sampling intervals. The majority of variability of BTM BLV ELISA results was seen between herds (1-month, 6.792 ± 0.533; 3-month, 7.806 ± 0.652; 3-year, 6.222 ± 0.528). Unexplained variance between samples from the same herd, on square-root scale, was greatest for the 3-year (0.976 ± 0.104), followed by the 1-month (0.611 ± 0.035) then the 3-month (0.557 ± 0.071) intervals. Variability of BTM antibody levels within the same herd was present but was much smaller than the variability between herds, and was greatest for the 3-year sampling interval. The 3-month sampling interval resulted in the least variability and is appropriate to use for estimating the baseline level of within-herd prevalence for BLV control programs. Knowledge of the baseline variability and within-herd prevalence can help to determine effectiveness of control programs when BTM sampling is repeated at longer intervals. Copyright © 2018 Elsevier B.V. All rights reserved.
Würzner, Reinhard; Tedesco, Francesco; Garred, Peter; Mollnes, Tom Eirik; Truedsson, Lennart; Turner, Malcolm W; Sommarin, Yngve; Wieslander, Jörgen; Sim, Robert B
2015-11-01
A whole complement ELISA-based assay kit, primarily designed to screen for deficiencies in components of the complement system was developed during a European Union grant involving more than a dozen European scientists and a small-medium enterprise company (Wieslab, which later merged into Eurodiagnostica). The consortium was led by Prof. Mohamed R. Daha who had already guided a preceding European grant which prepared the ground for this endeavor to create a novel and sophisticated complement measurement tool. The final result of the grant was a scientific publication (Seelen et al., 2005, J. Immunol. Methods 296, 187-198) and a commercially available complement deficiency screening kit, WIESLAB(®) Complement system Screen. Thereafter, the group decided to carry on with a grant, located at Innsbruck Medical University, and supported by royalties and unrestricted educational grants from Eurodiagnostica, Malmö, entitled "Search for Applications for WIESLAB(®) Complement system Screen (SAW)" with the aim to look for further applications of this assay. During the latter project the group organized several scientific meetings aimed at evaluating the use of the assay as well as developing further branches of its platform. A look back over almost two decades reveals a great story of excellent research which was also commercially successful, fulfilling the aims of European Union grants. It is also a story of ageless friendship, only possible due to the vision and guidance of an exceptional manager: Moh Daha. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yoshida, Taisuke; Ishikawa, Masatomo; Niitsu, Tomihisa; Nakazato, Michiko; Watanabe, Hiroyuki; Shiraishi, Tetsuya; Shiina, Akihiro; Hashimoto, Tasuku; Kanahara, Nobuhisa; Hasegawa, Tadashi; Enohara, Masayo; Kimura, Atsushi; Iyo, Masaomi; Hashimoto, Kenji
2012-01-01
Meta-analyses have identified serum levels of brain-derived neurotrophic factor (BDNF) as a potential biomarker for major depressive disorder (MDD). However, at the time, commercially available human ELISA kits are unable to distinguish between proBDNF (precursor of BDNF) and mature BDNF because of limited BDNF antibody specificity. In this study, we examined whether serum levels of proBDNF, mature BDNF, and matrix metalloproteinase-9 (MMP-9), which converts proBDNF to mature BDNF, are altered in patients with MDD. Sixty-nine patients with MDD and 78 age- and gender-matched healthy subjects were enrolled. Patients were evaluated using 17 items on the Structured Interview Guide for the Hamilton Depression Rating Scale. Cognitive impairment was evaluated using the CogState battery. Serum levels of proBDNF, mature BDNF, and MMP-9 were measured using ELISA kits. Serum levels of mature BDNF in patients with MDD were significantly lower than those of normal controls. In contrast, there was no difference in the serum levels of proBDNF and MMP-9 between patients and normal controls. While neither proBDNF nor mature BDNF serum levels was associated with clinical variables, there were significant correlations between MMP-9 serum levels and the severity of depression, quality of life scores, and social function scores in patients. These findings suggest that mature BDNF may serve as a biomarker for MDD, and that MMP-9 may play a role in the pathophysiology of MDD. Further studies using larger sample sizes will be needed to investigate these results.
Measurement of salivary adiponectin concentrations in dogs.
Tvarijonaviciute, Asta; Carrillo-Sanchez, Juana D; García-Martinez, Juan D; Tecles, Fernando; Martinez-Subiela, Silvia; German, Alexander J; Ceron, Jose J
2014-09-01
Measurement of salivary adiponectin could improve understanding of this adipokine's physiology, and its role in various clinical conditions. The purpose of the study was to evaluate the utility of a human adiponectin ELISA kit for measurement of salivary adiponectin in dogs, to compare serum and salivary adiponectin concentrations in a healthy dog population, and to evaluate possible effects of tooth-cleaning on serum and salivary adiponectin concentrations in dogs. For analytical validation, precision, accuracy, and lower limit of quantification of the assay were determined with saliva samples. In addition, adiponectin concentrations were quantified in serum and saliva samples from 24 healthy dogs, and from 7 dogs with mild gingivitis before and after a tooth-cleaning procedure. The validation assays for salivary adiponectin had all coefficients of variation <15%, and recovery ranged from 85% to 120%. In the linearity test, interference was observed when measuring adiponectin in saliva, but this was solved by diluting samples 1:4. In healthy dogs, salivary and serum adiponectin concentrations were positively correlated (r = .650; P = .009). After the tooth-cleaning procedure, salivary adiponectin concentration increased on day 0 (P = .004), but by day 14, concentrations were less than prior to the procedure (P = .041). The human adiponectin ELISA kit can be used for precise and accurate salivary adiponectin measurement in dogs. Salivary adiponectin increased 24 hours after tooth-cleaning, possibly due to acute inflammation or adiponectin leakage from the blood after gingival trauma. © 2014 American Society for Veterinary Clinical Pathology and European Society for Veterinary Clinical Pathology.
Bommareddy, Ajay; Rule, Brittny; VanWert, Adam L; Santha, Sreevidya; Dwivedi, Chandradhar
2012-06-15
The anticancer effects of α-santalol, a major component of sandalwood oil, have been reported against the development of certain cancers such as skin cancer both in vitro and in vivo. The primary objectives of the current study were to investigate the cancer preventive properties of α-santalol on human prostate cancer cells PC-3 (androgen independent and P-53 null) and LNCaP (androgen dependent and P-53 wild-type), and determine the possible mechanisms of its action. The effect of α-santalol on cell viability was determined by trypan blue dye exclusion assay. Apoptosis induction was confirmed by analysis of cytoplasmic histone-associated DNA fragmentation using both an apoptotic ELISA kit and a DAPI fluorescence assay. Caspase-3 activity was determined using caspase-3 (active) ELISA kit. PARP cleavage was analyzed using immunoblotting. α-Santalol at 25-75 μM decreased cell viability in both cell lines in a concentration and time dependent manner. Treatment of prostate cancer cells with α-santalol resulted in induction of apoptosis as evidenced by DNA fragmentation and nuclear staining of apoptotic cells by DAPI. α-Santalol treatment also resulted in activation of caspase-3 activity and PARP cleavage. The α-santalol-induced apoptotic cell death and activation of caspase-3 was significantly attenuated in the presence of pharmacological inhibitors of caspase-8 and caspase-9. In conclusion, the present study reveals the apoptotic effects of α-santalol in inhibiting the growth of human prostate cancer cells. Copyright © 2012 Elsevier GmbH. All rights reserved.
Nekouei, Omid; Stryhn, Henrik; VanLeeuwen, John; Kelton, David; Hanna, Paul; Keefe, Greg
2015-11-01
Enzootic bovine leukosis (EBL) is an economically important infection of dairy cattle caused by bovine leukemia virus (BLV). Estimating the prevalence of BLV within dairy herds is a fundamental step towards pursuing efficient control programs. The objectives of this study were: (1) to determine the prevalence of BLV infection at the herd level using a bulk-tank milk (BTM) antibody ELISA in the Maritime region of Canada (3 provinces); and (2) to develop appropriate statistical models for predicting within-herd prevalence of BLV infection using BTM antibody ELISA titers. During 2013, three monthly BTM samples were collected from all dairy farms in the Maritime region of Canada (n=623) and tested for BLV milk antibodies using a commercial indirect ELISA. Based on the mean of the 3 BTM titers, 15 strata of herds (5 per province) were defined. From each stratum, 6 herds were randomly selected for a total of 90 farms. Within every selected herd, an additional BTM sample was taken (round 4), approximately 2 months after the third round. On the same day of BTM sampling, all cows that contributed milk to the fourth BTM sample were individually tested for BLV milk antibodies (n=6111) to estimate the true within-herd prevalence for the 90 herds. The association between true within-herd prevalence of BLV and means of various combinations of the BTM titers was assessed using linear regression models, adjusting for the stratified random sampling design. Herd level prevalence of BLV in the region was 90.8%. In the individual testing, 30.4% of cows were positive. True within-herd prevalences ranged from 0 to 94%. All linear regression models were able to predict the true within-herd prevalence of BLV reasonably well (R(2)>0.69). Predictions from the models were particularly accurate for low-to-medium spectrums of the BTM titers. In general, as a greater number of the four repeated BTM titers were incorporated in the models, narrower confidence intervals around the prediction lines were achieved. The model including all 4 BTM tests as the predictor had the best fit, although the models using 2 and 3 BTM tests provided similar results to 4 repeated tests. Therefore, testing two or three BTM samples with approximately two-month intervals would provide relatively precise estimates for the potential number of infected cows in a herd. The developed models in this study could be applied to control and eradication programs for BLV as cost-effective tools. Copyright © 2015 Elsevier B.V. All rights reserved.
Collins, Á B; Grant, J; Barrett, D; Doherty, M L; Hallinan, A; Mee, J F
2017-08-01
Schmallenberg virus (SBV) is transmitted by Culicoides spp. biting midges and can cause abortions and congenital malformations in ruminants and milk drop in dairy cattle. Estimating true within-herd seroprevalence is an essential component of efficient and cost-effective SBV surveillance programs. The objectives of this study were: (1) determine the correlation between bulk-tank milk (BTM)-ELISA results and within-herd seroprevalence, (2) evaluate the ability of BTM-ELISA results to predict within-herd seroprevalence and (3) explore the distributions of individual animal serology results using novel statistical methodology. BTM samples (n=24) and blood samples (n=4019) collected from all lactating cows contributing to the BTM in 26 Irish dairy herds (58-444 cows/herd) in 2014 located in a region exposed to SBV in 2012/2013, were analysed for SBV-specific antibodies using IDVet ® ELISA kits. The correlation between BTM-ELISA results and within-herd seroprevalence was determined by calculating Pearson's correlation coefficient. Linear regression models were used to assess the ability of BTM-ELISA results to predict within-herd seroprevalence. The distributions of individual animal serology results were explored by determining the empirical distribution functions (EDF) of the individual animal serum ELISA results in each herd. EDFs were compared pairwise across herds, using the Kolmogorov-Smirnov statistical test. Herds with similar BTM-ELISA results, herds with similar within-herd seroprevalence and herds with similar mean-herd serology ELISA results were stratified in order to explore their respective paired-herd EDF comparisons. Statistical significance was set at p<0.05. Twenty-two herds were BTM-ELISA-positive (within-herd seroprevalence 30.6-100%) and two herds were BTM-ELISA-negative (within-herd seroprevalence 10.7 and 16.2%) indicating BTM-ELISA-negative herds can have seropositive animals present. BTM-ELISA results were highly correlated (r=0.807, p<0.0001) with, and predictive of (R 2 =0.832, p<0.0001) of within-herd seroprevalence. Predictions were most accurate for upper-range BTM-ELISA antibody titres, while they were less accurate at higher and lower antibody titres. This is likely a result of the overall high within-herd seroprevalence. In herds with similar BTM-ELISA results 82% of the paired-herd EDF comparisons were significantly different. In herds with similar within-herd seroprevalence and in herds with similar mean-herd serology ELISA results, 46% and 47% of the paired-herd EDF comparisons were significantly different, respectively. These results demonstrate that BTM antibody titres are highly predictive of within-herd seroprevalence in an SBV exposed region. Furthermore, exploring the serum EDFs revealed that the variation observed in the predicted within-herd seroprevalence in the regression models is likely a result of individual animal variation in serum antibody titres in these herds. Copyright © 2017 Elsevier B.V. All rights reserved.
Błachnio, Karina
2010-01-01
Detergents commonly used for solubilization of membrane proteins may be ionic or non-ionic. Exposing membrane proteins to detergents, however, can adversely affect their native structure, which can be a major hindrance for functional studies. This is especially true for proteins with multiple transmembrane domains. The ProteoExtract Transmembrane Protein Extraction Kit (TM-PEK), offered by Merck, provides a detergent-free novel reagents to enable the mild and efficient extraction of proteins containing seven transmembrane domains, such as GPCRs (G-Protein Coupled Receptors) e.g.: Frizzled-4 and CELSR-3, from mammalian cells. The fraction enriched in transmembrane proteins using TM-PEK is directly compatible with enzyme assays, non-denaturing gel electrophoresis, 1- and 2-D SDS-PAGE, MS analysis, Western blotting, immunoprecipitation and ELISA. Unlike many alternatives, TM-PEK extraction procedure does not require sonication, extended rigorous vortexing, ultracentrifugation, or incubation of samples at elevated temperatures--thus minimizing the risk of post-extraction degradation or modifications.
Tamarozzi, Francesca; Covini, Ilaria; Mariconti, Mara; Narra, Roberta; Tinelli, Carmine; De Silvestri, Annalisa; Manzoni, Federica; Casulli, Adriano; Ito, Akira; Neumayr, Andreas; Brunetti, Enrico
2016-01-01
Background The diagnosis of cystic echinococcosis (CE) is based primarily on imaging, in particular with ultrasound for abdominal CE, complemented by serology when imaging results are unclear. In rural endemic areas, where expertise in ultrasound may be scant and conventional serology techniques are unavailable due to lack of laboratory equipment, Rapid Diagnostic Tests (RDTs) are appealing. Methodology/Principal Findings We evaluated the diagnostic accuracy of 3 commercial RDTs for the diagnosis of hepatic CE. Sera from 59 patients with single hepatic CE cysts in well-defined ultrasound stages (gold standard) and 25 patients with non-parasitic cysts were analyzed by RDTs VIRapid HYDATIDOSIS (Vircell, Spain), Echinococcus DIGFA (Unibiotest, China), ADAMU-CE (ICST, Japan), and by RIDASCREEN Echinococcus IgG ELISA (R-Biopharm, Germany). Sensitivity, specificity and ROC curves were compared with McNemar and t-test. For VIRapid and DIGFA, correlation between semiquantitative results and ELISA OD values were evaluated by Spearman’s coefficient. Reproducibility was assessed on 16 randomly selected sera with Cohen’s Kappa coefficient. Sensitivity and Specificity of VIRapid (74%, 96%) and ADAMU-CE (57%, 100%) did not differ from ELISA (69%, 96%) while DIGFA (72%, 72%) did (p = 0.045). ADAMU-CE was significantly less sensitive in the diagnosis of active cysts (p = 0.019) while DIGFA was significantly less specific (p = 0.014) compared to ELISA. All tests were poorly sensitive in diagnosing inactive cysts (33.3% ELISA and ADAMU-CE, 42.8% DIGFA, 47.6% VIRapid). The reproducibility of all RDTs was good-very good. Band intensity of VIRapid and DIGFA correlated with ELISA OD values (r = 0.76 and r = 0.79 respectively, p<0.001). Conclusions/Significance RDTs may be useful in resource-poor settings to complement ultrasound diagnosis of CE in uncertain cases. VIRapid test appears to perform best among the examined kits, but all tests are poorly sensitive in the presence of inactive cysts, which may pose problems with accurate diagnosis. PMID:26871432
Gordon, D K; Roberts, L C P; Lean, N; Zadoks, R N; Sargison, N D; Skuce, P J
2013-07-01
The liver fluke, Fasciola hepatica, is common in many parts of Great Britain. To detect liver fluke infection and to assess whether fasciolicide treatment has been successful, the faecal egg count (FEC) and faecal egg count reduction test (FECRT) are widely used. Rumen fluke is also increasingly reported from Great Britain, but its species identity is yet to be determined. Liver fluke and rumen fluke eggs are morphologically similar, which may lead to erroneous diagnoses of liver fluke infection or treatment failure. As an alternative to FEC, a coproantigen ELISA (cELISA) can be used. The potential for this test to cross-react with rumen fluke species from Great Britain has not been evaluated. Rumen fluke specimens from cattle and sheep in Scotland were identified to species level using DNA sequencing of the ITS-2 region. Subsequently, rumen and liver fluke obtained from naturally co-infected sheep were subjected to immunohistochemistry using antibodies from a commercially available cELISA kit for F. hepatica. Finally, faecal samples from naturally co-infected sheep flocks were examined by FEC and cELISA. Rumen fluke from imported and home-bred cattle and sheep in Scotland belonged to the species Calicophoron daubneyi, rather than Paramphistomum cervi, the species presumed to be most common in Great Britain. Intense staining of the gastrodermis was observed in F. hepatica but cross-reactivity with C. daubneyi was not seen. Faecal samples that contained rumen fluke eggs but not liver fluke eggs were all negative by cELISA. We conclude that C. daubneyi is the most common rumen fluke of domestic ruminants in Scotland and that cELISA reduction testing may be a valuable alternative to FECRT in herds or flocks that are co-infected with liver and rumen fluke. Copyright © 2013 Elsevier B.V. All rights reserved.
Enzyme-linked immunosorbent assay for IgA antibodies to Trypanosoma cruzi in congenital infection.
Di Pentima, M C; Edwards, M S
1999-02-01
With the aim of achieving earlier diagnosis of congenital Trypanosoma cruzi infection, we assessed the usefulness of detecting specific IgA antibody by an ELISA. We evaluated 12 pregnant women chronically infected with T. cruzi, their newborn infants, and three additional neonates with parasitemia at birth. The IgA-specific antibody was detected by adapting the procedure for use of a commercial IgG ELISA, the Hemagen Chagas' Kit (Hemagen Diagnostics, Inc., Waltham, MA). Trypanosoma cruzi-specific IgA was detected in 10 (83%) of 12 mothers at delivery, in one of three parasitemic infants, and one of 12 newborns of the chronically infected women. Testing of 13 infants at six months of age revealed IgA in seven infants (54%), of whom four also had persistent T. cruzi-specific IgG. Detection of T. cruzi-specific IgA could provide a criterion for diagnosis of congenital infection in the absence of detectable parasitemia.
Thomas, Ekelijn; Bouma, Annemarie; van Eerden, Ellen; Landman, Wil J M; van Knapen, Frans; Stegeman, Arjan; Bergwerff, Aldert A
2006-08-31
A surface plasmon resonance (SPR) biosensor assay was developed on the basis of a lipopolysaccharide antigen of Salmonella enterica serovar enteritidis (S. enterica serovar enteritidis) to detect egg yolk antibodies against S. enterica serovar enteritidis. This biosensor assay was compared to two commercial ELISA kits based on LPS antigen and flagellar antigen. A number of 163 egg yolk and combined egg white and yolk samples from chickens experimentally infected with S. enterica serovar enteritidis and 90 egg yolk and combined egg white and yolk samples from uninfected chickens were analyzed. Receiver operating characteristic analysis of the data calculated a diagnostic sensitivity of 82% and a diagnostic specificity of 100%. The within-day coefficient of variation of a positive internal-control egg yolk was 1%. The SPR biosensor assay was able to detect antibodies in a significantly higher percentage of known positive samples than the commercial ELISA's. The anticipated use of the SPR biosensor assay is to determine the S. enterica serovar enteritidis serostatus of non-vaccinated layer hens.
Khuda, Sefat; Slate, Andrew; Pereira, Marion; Al-Taher, Fadwa; Jackson, Lauren; Diaz-Amigo, Carmen; Bigley, Elmer C; Whitaker, Thomas; Williams, Kristina
2012-05-02
Immunodetection of allergens in dark chocolate is complicated by interference from the chocolate components. The objectives of this study were to establish reference materials for detecting multiple allergens in dark chocolate and to determine the accuracy and precision of allergen detection by enzyme-linked immunosorbent assay (ELISA) before and after chocolate processing. Defatted peanut flour, whole egg powder, and spray-dried milk were added to melted chocolate at seven incurred levels and tempered for 4 h. Allergen concentrations were measured using commercial ELISA kits. Tempering decreased the detection of casein and β-lactoglobulin (BLG), but had no significant effect on the detection of peanut and egg. Total coefficients of variation were higher in tempered than untempered chocolate for casein and BLG, but total and analytical CVs were comparable for peanut and egg. These findings indicate that processing has a greater effect on recovery and variability of casein and BLG than peanut and egg detection in a dark chocolate matrix.
Servat, A; Feyssaguet, M; Blanchard, I; Morize, J L; Schereffer, J L; Boue, F; Cliquet, F
2007-01-10
This paper reports a new ELISA to measure the level of rabies anti-glycoprotein G antibodies after vaccination. The Platelia Rabies II kit was evaluated on different populations of dogs, cats and foxes. For each target species, sera from naive, unvaccinated and vaccinated animals were tested. Platelia Rabies II results were compared to the reference fluorescent antibody virus neutralisation test (for dogs and cats) and to a published in house ELISA test (for foxes). The Platelia Rabies II test was found to be highly specific whatever the species (more than 98%) using a cut-off value of 0.5 EU/ml. The index of sensitivity was between 92.4% and 94.5% for fox samples, and reached 83% for domestic carnivores. Data collected by testing field samples revealed that the rate of false negative results ranged between 8.9% and 11.1% and the rate of false positive results ranged between 1% and 2% for the dog/cat population. Therefore, the Platelia Rabies II test described here would be a good candidate for routine detection of rabies antibodies not only in domestic carnivores (within the framework of international trade) but also in foxes for the follow up of rabies oral vaccination programs.
A FLUORIMETRIC SEMI-MICROPLATE FORMAT ASSAY OF PROTEIN CARBONYLS IN BLOOD PLASMA
Mohanty, Joy G.; Bhamidipaty, Surya; Evans, Michele K.; Rifkind, Joseph M.
2010-01-01
Oxidative stress, originating from reactive oxygen species (ROS), has been implicated in aging and various human diseases. The ROS generated can oxidize proteins producing protein carbonyl derivatives. The level of protein carbonyls in blood plasma has been used as a measure of overall oxidative stress in the body. Classically, protein carbonyls have been quantitated spectrophotometrically by directly reacting them with 2,4, dinitrophenylhydrazine (DNPH). However, the applicability of this method to biological samples is limited by its low inherent sensitivity. This limitation has been overcome by the development of sensitive ELISA methods to measure protein carbonyls. As part of the Healthy Aging in Neighborhoods of Diversity across the Lifespan study, oxidative stress in humans were quantified by measuring blood plasma protein carbonyls using the two commercially available ELISA kits and the spectrophotometric DNPH assay. Surprisingly, two ELISA methods gave very different values for protein carbonyls that were both different from the spectrophotometric method. We have developed a fluorescent semi-microplate format assay of protein carbonyls involving direct reaction of protein carbonyls with fluorescein thiosemicarbazide that correlates (R=0.992) with the direct spectrophotometric method. It has a coefficient of variation of 4.99% and is at least 100 times more sensitive than the spectrophotometric method. PMID:20122892
Kruse, Niels; Persson, Staffan; Alcolea, Daniel; Bahl, Justyna M C; Baldeiras, Ines; Capello, Elisabetta; Chiasserini, Davide; Bocchio Chiavetto, Luisella; Emersic, Andreja; Engelborghs, Sebastiaan; Eren, Erden; Fladby, Tormod; Frisoni, Giovanni; García-Ayllón, María-Salud; Genc, Sermin; Gkatzima, Olymbia; Heegaard, Niels H H; Janeiro, André M; Kováčech, Branislav; Kuiperij, H Bea; Leitão, Maria J; Lleó, Alberto; Martins, Madalena; Matos, Mafalda; Mollergard, Hanne M; Nobili, Flavio; Öhrfelt, Annika; Parnetti, Lucilla; de Oliveira, Catarina Resende; Rot, Uros; Sáez-Valero, Javier; Struyfs, Hanne; Tanassi, Julia T; Taylor, Peggy; Tsolaki, Magda; Vanmechelen, Eugeen; Verbeek, Marcel M; Zilka, Norbert; Blennow, Kaj; Zetterberg, Henrik; Mollenhauer, Brit
2015-09-01
Decreased levels of alpha-synuclein (aSyn) in cerebrospinal fluid (CSF) in Parkinson's disease and related synucleinopathies have been reported, however, not consistently in all cross-sectional studies. To test the performance of one recently released human-specific enzyme-linked immunosorbent assay (ELISA) for the quantification of aSyn in CSF, we carried out a round robin trial with 18 participating laboratories trained in CSF ELISA analyses within the BIOMARKAPD project in the EU Joint Program - Neurodegenerative Disease Research. CSF samples (homogeneous aliquots from pools) and ELISA kits (one lot) were provided centrally and data reported back to one laboratory for data analysis. Our study showed that although factors such as preanalytical sample handling and lot-to-lot variability were minimized by our study design, we identified high variation in absolute values of CSF aSyn even when the same samples and same lots of assays were applied. We further demonstrate that although absolute concentrations differ between laboratories the quantitative results are comparable. With further standardization this assay may become an attractive tool for comparing aSyn measurements in diverse settings. Recommendations for further validation experiments and improvement of the interlaboratory results obtained are given. Copyright © 2015 Elsevier Inc. All rights reserved.
Simultaneous capture and sequential detection of two malarial biomarkers on magnetic microparticles.
Markwalter, Christine F; Ricks, Keersten M; Bitting, Anna L; Mudenda, Lwiindi; Wright, David W
2016-12-01
We have developed a rapid magnetic microparticle-based detection strategy for malarial biomarkers Plasmodium lactate dehydrogenase (pLDH) and Plasmodium falciparum histidine-rich protein II (PfHRPII). In this assay, magnetic particles functionalized with antibodies specific for pLDH and PfHRPII as well as detection antibodies with distinct enzymes for each biomarker are added to parasitized lysed blood samples. Sandwich complexes for pLDH and PfHRPII form on the surface of the magnetic beads, which are washed and sequentially re-suspended in detection enzyme substrate for each antigen. The developed simultaneous capture and sequential detection (SCSD) assay detects both biomarkers in samples as low as 2.0parasites/µl, an order of magnitude below commercially available ELISA kits, has a total incubation time of 35min, and was found to be reproducible between users over time. This assay provides a simple and efficient alternative to traditional 96-well plate ELISAs, which take 5-8h to complete and are limited to one analyte. Further, the modularity of the magnetic bead-based SCSD ELISA format could serve as a platform for application to other diseases for which multi-biomarker detection is advantageous. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Lion (Panthera leo) and cheetah (Acinonyx jubatus) IFN-gamma sequences.
Maas, Miriam; Van Rhijn, Ildiko; Allsopp, Maria T E P; Rutten, Victor P M G
2010-04-15
Cloning and sequencing of the full length lion and cheetah interferon-gamma (IFN-gamma) transcript will enable the expression of the recombinant cytokine, to be used for production of monoclonal antibodies and to set up lion and cheetah-specific IFN-gamma ELISAs. These are relevant in blood-based diagnosis of bovine tuberculosis, an important threat to lions in the Kruger National Park. Alignment of nucleotide and amino acid sequences of lion and cheetah and that of domestic cats showed homologies of 97-100%. Copyright 2009 Elsevier B.V. All rights reserved.
Lai, Wenqiang; Tang, Dianping; Zhuang, Junyang; Chen, Guonan; Yang, Huanghao
2014-05-20
This work reports on a simple and feasible colorimetric immunoassay with signal amplification for sensitive determination of prostate-specific antigen (PSA, used as a model) at an ultralow concentration by using a new enzyme-chromogenic substrate system. We discovered that glucose oxidase (GOx), the enzyme broadly used in enzyme-linked immunosorbent assay (ELISA), has the ability to stimulate in situ formation of squaric acid (SQA)-iron(III) chelate. GOx-catalyzed oxidization of glucose leads to the formation of gluconic acid and hydrogen peroxide (H2O2). The latter can catalytically oxidize iron(II) to iron(III), which can rapidly (<1 min) coordinate with the SQA. Formation of the iron-squarate complex causes the color of the solution to change from bluish purple to bluish red accompanying the increasing absorbance with the increment of iron(III) concentration. On the basis of the SQA-iron(III) system, a new immunoassay protocol with GOx-labeled anti-PSA detection antibody can be designed for the detection of target PSA on capture antibody-functionalized magnetic immunosensing probe, monitored by recording the color or absorbance (λ = 468 nm) of the generated SQA-iron(III) chelate. The absorbance intensity shows to be dependent on the concentration of target PSA. A linear dependence between the absorbance and target PSA concentration is obtained under optimal conditions in the range from 1.0 pg mL(-1) to 30 ng mL(-1) with a detection limit (LOD) of 0.5 pg mL(-1) (0.5 ppt) estimated at the 3Sblank level. The sensitivity displays to be 3-5 orders of magnitude better than those of most commercialized human PSA ELISA kits. In addition, the developed colorimetric immunoassay was validated by assaying 12 human serum samples, receiving in good accordance with those obtained by the commercialized PSA ELISA kit. Importantly, the SQA-based immunosensing system can be further extended for the detection of other low-abundance proteins or biomarkers by controlling the target antibody.
Reverchon, Maxime; Ramé, Christelle; Cognié, Juliette; Briant, Eric; Elis, Sébastien; Guillaume, Daniel; Dupont, Joëlle
2014-01-01
Resistin is an adipokine that has been implicated in energy metabolism regulation in rodents but has been little studied in dairy cows. We determined plasma resistin concentrations in early lactation in dairy cows and investigated the levels of resistin mRNA and protein in adipose tissue and the phosphorylation of several components of insulin signaling pathways one week post partum (1 WPP) and at five months of gestation (5 MG). We detected resistin in mature bovine adipocytes and investigated the effect of recombinant bovine resistin on lipolysis in bovine adipose tissue explants. ELISA showed that plasma resistin concentration was low before calving, subsequently increasing and reaching a peak at 1 WPP, decreasing steadily thereafter to reach pre-calving levels at 6 WPP. Plasma resistin concentration was significantly positively correlated with plasma non esterified fatty acid (NEFA) levels and negatively with milk yield, dry matter intake and energy balance between WPP1 to WPP22. We showed, by quantitative RT-PCR and western blotting, that resistin mRNA and protein levels in adipose tissue were higher at WPP1 than at 5 MG. The level of phosphorylation of several early and downstream insulin signaling components (IRβ, IRS-1, IRS-2, Akt, MAPK ERK1/2, P70S6K and S6) in adipose tissue was also lower at 1 WPP than at 5 MG. Finally, we showed that recombinant bovine resistin increased the release of glycerol and mRNA levels for ATGL (adipose triglyceride lipase) and HSL (hormone-sensitive lipase) in adipose tissue explants. Overall, resistin levels were high in the plasma and adipose tissue and were positively correlated with NEFA levels after calving. Resistin is expressed in bovine mature adipocytes and promotes lipid mobilization in adipose explants in vitro. PMID:24675707
Antibody-independent identification of bovine milk-derived peptides in breast-milk.
Picariello, Gianluca; Addeo, Francesco; Ferranti, Pasquale; Nocerino, Rita; Paparo, Lorella; Passariello, Annalisa; Dallas, David C; Robinson, Randall C; Barile, Daniela; Canani, Roberto Berni
2016-08-10
Exclusively breast-fed infants can exhibit clear signs of IgE or non IgE-mediated cow's milk allergy. However, the definite characterization of dietary cow's milk proteins (CMP) that survive the maternal digestive tract to be absorbed into the bloodstream and secreted into breast milk remains missing. Herein, we aimed at assessing possible CMP-derived peptides in breast milk. Using high performance liquid chromatography (HPLC)-high resolution mass spectrometry (MS), we compared the peptide fraction of breast milk from 12 donors, among which 6 drank a cup of milk daily and 6 were on a strict dairy-free diet. We identified two bovine β-lactoglobulin (β-Lg, 2 out 6 samples) and one αs1-casein (1 out 6 samples) fragments in breast milk from mothers receiving a cup of bovine milk daily. These CMP-derived fragments, namely β-Lg (f42-54), (f42-57) and αs1-casein (f180-197), were absent in milk from mothers on dairy-free diet. In contrast, neither intact nor hydrolyzed β-Lg was detected by western blot and competitive ELISA in any breast milk sample. Eight additional bovine milk-derived peptides identified by software-assisted MS were most likely false positive. The results of this study demonstrate that CMP-derived peptides rather than intact CMP may sensitize or elicit allergic responses in the neonate through mother's milk. Immunologically active peptides from the maternal diet could be involved in priming the newborn's immune system, driving a tolerogenic response.
Delooz, L; Czaplicki, G; Houtain, J Y; Dal Pozzo, F; Saegerman, C
2017-08-01
Abortions cause heavy economic losses for the bovine sector. The use of a standardized panel of analyses covering a large spectrum of pathogens responsible of abortion in cattle allowed demonstrating the direct involvement of at least one pathogen in 57% of analysed abortions in the southern part of Belgium. This result suggests a margin of improvement in the diagnostic efficacy. In order to evaluate the interest to broaden the list of pathogens included in the panel of analyses, the implication of bovine herpesvirus 4 (BoHV-4) in abortion was assessed by two different studies. In the first study, coupled serology was performed after abortion on 714 dams to identify specific seroconversion against BoHV-4. The overall seroconversion in cows was 19.5%, with a higher frequency in primiparous compared to multiparous females. In addition, the type of breed (beef cattle) and the time period from the fourth quarter 2008 until the last quarter 2009 were significantly related to the seroconversion of cows. The second study investigated the virus ability to infect the foetus. In this study, 368 cases of bovine abortions were specifically tested for BoHV-4, using PCR on foetus tissues and ELISA on dam and foetus sera. The results showed a maternal seroprevalence of 64.7%, a foetal seroprevalence of 0.8% and a PCR prevalence in foetuses of 1.1%, demonstrating the ability of BoHV-4 to infect the foetus. © 2016 Blackwell Verlag GmbH.
Serological Follow-up of Tuberculosis in a Wild Boar Population in Contact with Infected Cattle.
Pérez de Val, B; Napp, S; Velarde, R; Lavín, S; Cervera, Z; Singh, M; Allepuz, A; Mentaberre, G
2017-02-01
There is an increasing concern in several European countries over the role that tuberculosis (TB)-infected wild boar may play in the progress of bovine TB eradication campaigns. In 2004, as a consequence of the detection of a TB focus in wild boar from a National Game Reserve (NGR) located in southern Catalonia, a surveillance programme based on post-mortem inspection for detection of macroscopic TB-like lesions (TBLL) was initiated in the affected area. The source of infection for wild boar was linked to a tuberculous cattle herd located in the same area. Besides, the results of the surveillance programme in wild boar were used for the validation of an indirect enzyme-linked immunosorbent assay (ELISA) specific for Mycobacterium tuberculosis complex (MTBC) IgG antibodies. Using this ELISA, a seven-year serological study of MTBC in wild boar from the NGR was conducted in 173 animals (93 adults, 44 juveniles-yearlings and 36 piglets) culled between 2004 and 2010. ELISA results and presence of TBLL showed excellent agreement for adult and juvenile wild boar (Kappa index = 0.85; 95% CI: 0.76-0.95). Of the thirty-eight adults, yearlings and juveniles classified as positives by the ELISA, 34 (89%) showed TBLL at necropsy. In contrast, none of the ELISA-positive wild boar piglets (n = 20) showed TBLL, suggesting the detection of early antibody responses to the infection. Overall, this study contributes to the knowledge of wild boar humoral responses to MTBC. The results also highlight the usefulness of this serological test for wild boar TB surveillance. © 2015 Blackwell Verlag GmbH.
Essome, Marie Chantal Ngonde; Nsawir, Bonglaisin Julius; Nana, Rodrigue Dongang; Molu, Patrick; Mohamadou, Mansour
2016-01-01
Introduction Les infections sexuellement transmissibles sévissent toujours dans les pays en voie de développement et particulièrement au Cameroun. Le but de notre étude est de déterminer la distribution des infections sexuellement transmissibles suivantes: l’hépatite virale B, le Chlamydia trachomatis et de la syphilis dans une population de femmes venant consulter spontanément à l’Hôpital de District de Nkoldongo à Yaoundé, d’évaluer d’éventuelles coïnfections entre ces trois affections et de ressortir les connaissances de ces femmes sur leur mode de transmission sexuelle. Méthodes Notre étude prospective et descriptive a porté sur 182 femmes dont l’âge variait entre 18 et 48 ans. Les femmes ont été testées sérologiquement pour le Chlamydia trachomatis par une méthode ELISA (kit des laboratoires General Biological Corp). L’hépatite virale B a été dépistée par une méthode immunochromatographique (kit des laboratoires Human) et la syphilis par une méthode d’agglutination en ce qui concerne le RPR (Kit des laboratoires Biocentric) et le TPHA (kit des laboratoires Human). Résultats Nos résultats ont montré que: la distribution du Chlamydia trachomatis, de l’hépatite virale B et la syphilis a été respectivement de 22,52%, 4,39%, 0,54%.De plus, nous avons observé une coinfection Chlamydia trachomatis hépatite virale B avec un taux de 2,74%. Par ailleurs la réinfection au Chlamydia trachomatis a été rencontrée dans 4,94% de cas. S’agissant du mode de transmission de ces affections 67,57% et 70,87% de femmes ne connaissaient pas la voie de transmission sexuelle pour le Chlamydia trachomatis et pour l’hépatite virale B respectivement, tandis que 91,2 % des femmes connaissaient la voie de transmission sexuelle pour la syphilis. Conclusion Le diagnostic d’une infection à Chlamydia trachomatis chez une patiente doit susciter le dépistage de l’hépatite virale B. Introduction Sexually transmitted infections are still frequent in developing countries and particularly in Cameroon. The aim of this study was to determine the distribution of the following sexually transmitted infections: viral hepatitis B, Chlamydia trachomatis and syphilis in a population of women spontaneously visiting the Nkoldongo District Hospital in Yaoundé as well as to evaluate possible co-infections among these three conditions and to bring out women’s prior knowledge of how sexual transmission occurs. Methods We conducted a prospective and descriptive study including 182 women aged between 18 and 48 years. These women underwent serologic testing for Chlamydia trachomatis with ELISA (General Biological Corp laboratory test kit. Hepatitis B virus was detected using immunochromatographic method (Human laboratory kit) while syphilis was detected using RPR agglutination (Biocentric Laboratories kit )and TPHA agglutination (Human laboratory kit) method. Results Our results showed that the distribution of Chlamydia trachomatis, viral hepatitis B and syphilis was 22.52%, 4.39%, 0.54% respectively. Moreover, we reported a Chlamydia trachomatis and Viral hepatitis B coinfection rate of 2.74%. In addition, Chlamydia trachomatis reinfection was detected in 4.94% of cases. Regarding the mode of transmission of these infections, 67.57% and 70.87% of women didn’t know how Chlamydia trachomatis and viral hepatitis sexual transmission could occur respectively, while 91.2% of women knew how was syphilis spread. Conclusion The diagnosis of chlamydia trachomatis infection should prompt screening for viral hepatitis B. PMID:28293360
Peste des petits ruminants infection in domestic ruminants in Sudan.
Intisar, K S; Ali, Y H; Haj, M A; Sahar, M A T; Shaza, M M; Baraa, A M; Ishag, O M; Nouri, Y M; Taha, K M; Nada, E M; Ahmed, A M; Khalafalla, A I; Libeau, G; Diallo, A
2017-04-01
The existence of peste des petits ruminants (PPR) in domestic ruminants and camels in Sudan during 2008-2012 was investigated. Lung tissues and serum samples were randomly collected from sheep, goats, cattle, and camels at different areas of Sudan. A total of 12,384 serum samples were collected from clinically healthy 7413 sheep, 1988 camels, 1501 cattle, 1459 goats, and 23 gazelles at different areas in the Sudan. They were examined for PPR antibodies using competitive ELISA (cELISA). The overall detected seroprevalence of PPR in tested sera was 49.4%; seroprevalence values within species were 67.1, 48.2, 25.8, 2.1, and 21.7% in sheep, goat, cattle, camels, and gazelles, respectively. The highest seroprevalence (68.1%) was observed in sera collected from Darfur states, then the central states (54.3%). A total of 1276 lung tissue samples (623 sheep, 324 cattle, 220 camels, and 109 goats) were collected. The majority of lung samples were collected from clinically healthy animals that showed lesions on PM in slaughterhouses (95%) and during PPR outbreaks; samples were tested for PPR antigen using immunocapture ELISA (IcELISA). PPR antigen was detected in 233 out of the 1276 tested samples (18.3%). Positive results were observed in samples collected from clinically healthy and diseased animals. The observed prevalence values in each species were 33.6, 21.1, 15.4, and 12.3% in camel, goat, sheep, and cattle, respectively. PPR antigen was detected in samples from different areas; however, the highest prevalence (63.9%) was found in samples collected from the eastern states, then Khartoum state (28%). Trials for virus isolation were done in different cell cultures. Out of 30 IcELISA-positive samples inoculated in primary bovine and ovine kidney cells, Vero cells, the PPR virus was successfully isolated from 15 (eight sheep, five camels, and two goats) samples in the three cell culture types. Using RT-PCR, PPRV nucleic acid was detected in all 25 IcELISA-positive tested samples.
Cai, Yu-Chun; Chen, Shao-Hong; Tian, Li-Guang; Chu, Yan-Hong; Lu, Yan; Chen, Mu-Xin; Ai, Lin; Zhou, Yang; Chen, Jia-Xu
2014-02-01
To establish A1E3 and B1C4 monoclonal antibody-based ELISA for detecting circulating antigen of Schistosoma japonicum and explore its application value in the field. The characteristics of A1E3 and B1C4 monoclonal antibodies were analyzed by SDS-PAGE and Western blotting. The SEA-based ELISA was used to evaluate the titers of A1E3 and B1C4. The orthogonal test was used to determine the best concentration of coating antibody B1C4 and optimal working concentration of A1E3-HRP. Under the optimal conditions, the serum samples of 20 acute schistosomiasis cases, 46 chronic schistosomiasis cases, and 20 control sera were tested to evaluate its detection sensitivity and specificity. Seventy-two antibody positive serum samples from Jiangling County of Hubei Province were detected and compared to a commercially available ELISA kit, to evaluate the detection effects of this method. The results of SDS-PAGE demonstrated that the purified A1E3 and B1C4 contained a clear heavy chain with molecular weight of 88,000 and 52,000 respectively and had the same light chain with molecular weight of 20,000; while Western blotting demonstrated that A1E3 and B1C4 could be recognized by SEA and serum samples of acute schistosomiasis cases. The SEA-based ELISA demonstrated the titers of B1C4 and A1E3 were 1:10(5) and 1:30,000, respectively. The serum samples from all the acute cases and 86.9% of the chronic cases showed a positive reaction. All of the control sera from healthy persons gave a negative response. The positive rates of the double monoclonal antibody ELISA and commercial ELISA for detecting the circulating antigen were 45.8% and 43.1% respectively, and there was no significant difference between the results of the two methods. A1E3 and B1C4 monoclonal antibody-based ELISA is established successfully. It exhibits a high sensitivity and specificity in detecting circulating antigen of Schistosoma japonicum.
Quantitation of exposure to benzo[a]pyrene with monoclonal antibodies.
Santella, R M; Hsieh, L L; Lin, C D; Viet, S; Weinstein, I B
1985-01-01
It is now possible to quantitate carcinogen adducts on DNA by highly sensitive immunoassays. These techniques are particularly useful for screening human populations for exposure to potential environmental carcinogens. We have developed a panel of monoclonal antibodies that react with benzo(a)pyrene (BP) modified DNA to be used in an enzyme linked immunoassay (ELISA) to quantitate adduct levels of both human and animal samples. BALBc/Cr mice were immunized with either DNA modified by 7 beta, 8 alpha-dihydroxy-9 alpha, 10 alpha-epoxy-7,8,9, 10-tetrahydrobenzo(a)pyrene (BPDE-I-DNA) complexed electrostatically to methylated bovine serum albumin or with BPDE-I-modified guanosine conjugated with bovine serum albumin (BPDE-I-G-BSA). Four stable clones were produced from the spleen cells of animals immunized with BPDE-I-DNA and one from BPDE-I-G-BSA immunized animals. All antibodies were shown to be highly specific for BPDE-I-DNA and did not crossreact with nonmodified DNA or with N-2-acetylaminofluorene or 1-aminopyrene modified DNA. The antibodies differed in their sensitivity to BPDE-II-DNA, BPDE-I-poly G, BPDE-I-tetraols and BPDE-I-dG. In general, all the antibodies showed the greatest affinity for their original antigen. Those generated against modified DNA showed highest reactivity against modified DNA while the one antibody generated against the monoadduct showed highest reactivity with the monoadduct. These antibodies are currently being used in a highly sensitive competitive ELISA to quantitate levels of BP-DNA adducts in various animal and human tissue samples. PMID:4085452
Mosher, Ruby A; Coetzee, Johann F; Allen, Portia S; Havel, James A; Griffith, Gary R; Wang, Chong
2014-02-01
To determine the effects of protease inhibitors and holding times and temperatures before processing on the stability of substance P in bovine blood samples. Blood samples obtained from a healthy 6-month-old calf. Blood samples were dispensed into tubes containing exogenous substance P and 1 of 6 degradative enzyme inhibitor treatments: heparin, EDTA, EDTA with 1 of 2 concentrations of aprotinin, or EDTA with 1 of 2 concentrations of a commercially available protease inhibitor cocktail. Plasma was harvested immediately following collection or after 1, 3, 6, 12, or 24 hours of holding at ambient (20.3° to 25.4°C) or ice bath temperatures. Total substance P immunoreactivity was determined with an ELISA; concentrations of the substance P parent molecule, a metabolite composed of the 9 terminal amino acids, and a metabolite composed of the 5 terminal amino acids were determined with liquid chromatography-tandem mass spectrometry. Regarding blood samples processed immediately, no significant differences in substance P concentrations or immunoreactivity were detected among enzyme inhibitor treatments. In blood samples processed at 1 hour of holding, substance P parent molecule concentration was significantly lower for ambient temperature versus ice bath temperature holding conditions; aprotinin was the most effective inhibitor of substance P degradation at the ice bath temperature. The ELISA substance P immunoreactivity was typically lower for blood samples with heparin versus samples with other inhibitors processed at 1 hour of holding in either temperature condition. Results suggested that blood samples should be chilled and plasma harvested within 1 hour after collection to prevent substance P degradation.
Feng, Tang; Jian-Xia, Tang; Feng, Lu; Sui, Xu; Ya-Ping, Gu; De-Sheng, Tong; Guo-Ding, Zhu; Hai-Yong, Hua; Hua-Yun, Zhou; Jun, Cao
2016-03-21
To evaluate the Wondfo Rapid Diagnostic Kit (Pf-LDH/Pan -pLDH) for detecting Plasmodium ovale and analyze the influence of parasitaemia, concentration and polymorphism of pLDH on the performances. A total of 100 blood samples from P. ovale patients confirmed by PCR were detected with the Wondfo Rapid Diagnostic Kit according to the manufacturers'instructions. The parasitaemia was determined by the microscopic examination. The concentration of pLDH was measured by ELISA tests. The LDH gene of P. ovale was amplified by PCR and sequenced. The influence of these three factors on the positive rate was analyzed. The overall positive rate of Wondfo Rapid Diagnostic Kit was 70.0% (70/100). The positive rate was 27.3% for the samples with parasitaemia ≤ 500 parasites/μl and reached 75.0%-75.4% when parasitaemia > 500 parasites/μl. The positive rate was 6.7% for samples with a low pLDH concentration ( A values ≤ 0.100) and reached 95.1%-100% at a high pLDH concentration ( A values > 0.100). The results of sequence analysis indicated that all the samples could be divided into 2 types, P. o. curtisi and P. o. wallikeri . The gene homology of LDH between 2 types was 97%. There were 24 single nucleotide polymorphism (s) (SNPs) between 2 types, while only 3 SNPs were non-synonymous mutations. The homology of LDH amino acid sequences between 2 types was 99%; only 3 amino acids were different. The positive rates for P. o. curtisi and P. o. wallikeri were 73.1% (38/52) and 66.7% (32/48) respectively; there was no statistically significant difference ( P > 0.05). The Wondfo Rapid Diagnostic Kit (Pf-LDH/Pan-pLDH) performs better than most of the similar products for the detection of P. ovale , and the positive rates are closely related to the parasitaemia and concentration of pLDH, while no related to the polymorphism of pLDH gene.
Kazemi, Rezvan; Taheri-Kafrani, Asghar; Motahari, Ahmad; Kordesedehi, Reihane
2018-06-01
Nowadays health benefits of bioactive food constituents, known as probiotic microorganisms, are a growing awareness. Cow's milk is a nutritious food containing probiotic bacteria. However, milk allergenicity is one of the most common food allergies. The milk protein, β-lactoglobulin (BLG), is in about 80% of all main cases of milk allergies for children and infants. With the aim of screening proteolytic strains of lactic acid bacteria to evaluate their potential for the reduction of allergenicity of the major bovine milk proteins, we isolated new proteolytic strains of cocci lactic acid bacteria from traditional Iranian dairy products. The proteases produced by these strains had strong proteolytic activity against BLG. Proteolysis of BLG, observed after sodium dodecyl sulfate-PAGE, was confirmed by the analysis of the peptide profiles by reversed-phase HPLC. The two isolates were submitted to 16S rDNA sequencing and identified as Lactcoccus lactis subsp. cremoris and Lactcoccus lactis subsp. hordniea. The competitive ELISA experiments confirmed that these isolates, with high proteolytic activity, reduce significantly the allergenicity of BLG. Accordingly, these isolates can reduce the immunoreactivity of bovine milk proteins, which can be helpful for the production of low-allergic dairy products. Copyright © 2018 Elsevier B.V. All rights reserved.
[Eradication of Prototheca zopfii infection in a dairy cattle herd].
Rösler, U; Hensel, A
2003-09-01
Protothecosis is a severe form of mastitis in dairy cows caused by colorless algae of the genus Prototheca. Since P. zopfii is highly resistant to all known chemotherapeutics, infected cows must be removed from the herd. Eradication measures are difficult since many chronically infected cows may become intermittent shedders. Therefore, cultural methods are insufficient for control measures. In order to eradicate Prototheca zopfii-mastitis in dairy cattle herds, two isotype specific indirect ELISA for detection of IgA and IgG1 in whey were used in a dairy herd highly affected with protothecal mastitis. All cows (n = 313) were tested four times in intervals of six months. Milk specimens were examined in parallel by cultivation and serologically using two indirect ELISA systems for specific IgA and IgG1 in whey. Cows tested Prototheca positive were consequently separated from the herd and slaughtered. At the first examination, 15.6% of the animals were found positive by culture, and 23.3% were positive in at least one of the ELISA systems. Within two years, protothecal prevalence and incidence decreased to zero indicating that the eradication strategy used was successful. In summary, serological identification of P. zopfii-infected lactating cows is an useful tool to eradicate protothecal bovine mastitis in infected herds.
Goff, Will L.; McElwain, Terry F.; Suarez, Carlos E.; Johnson, Wendell C.; Brown, Wendy C.; Norimine, Junzo; Knowles, Donald P.
2003-01-01
The competitive enzyme-linked immunosorbent assay (cELISA) format has proven to be an accurate, reliable, easily standardized, and high-throughput method for detecting hemoparasite infections. In the present study, a species-specific, broadly conserved, and tandemly repeated B-cell epitope within the C terminus of the rhoptry-associated protein 1 of the hemoparasite Babesia bovis was cloned and expressed as a histidine-tagged thioredoxin fusion peptide and used as antigen in a cELISA. The assay was optimized with defined negative and positive bovine sera, where positive sera inhibited the binding of the epitope-specific monoclonal antibody BABB75A4. The cELISA accurately differentiated animals with B. bovis-specific antibodies from uninfected animals and from animals with antibodies against other tick-borne hemoparasites (98.7% specificity). In addition, B. bovis-specific sera from Australia, Argentina, Bolivia, Puerto Rico, and Morocco inhibited the binding of BABB75A4, confirming conservation of the epitope. The assay first detected experimentally infected animals between 13 and 17 days postinfection, and with sera from naturally infected carrier cattle, was comparable to indirect immunofluorescence (98.3% concordance). The assay appears to have the characteristics necessary for an epidemiologic and disease surveillance tool. PMID:12522037
Murdock, Richard J; Putnam, Shawn A; Das, Soumen; Gupta, Ankur; Chase, Elyse D Z; Seal, Sudipta
2017-03-01
A clinically relevant magneto-optical technique (fd-FRS, frequency-domain Faraday rotation spectroscopy) for characterizing proteins using antibody-functionalized magnetic nanoparticles (MNPs) is demonstrated. This technique distinguishes between the Faraday rotation of the solvent, iron oxide core, and functionalization layers of polyethylene glycol polymers (spacer) and model antibody-antigen complexes (anti-BSA/BSA, bovine serum albumin). A detection sensitivity of ≈10 pg mL -1 and broad detection range of 10 pg mL -1 ≲ c BSA ≲ 100 µg mL -1 are observed. Combining this technique with predictive analyte binding models quantifies (within an order of magnitude) the number of active binding sites on functionalized MNPs. Comparative enzyme-linked immunosorbent assay (ELISA) studies are conducted, reproducing the manufacturer advertised BSA ELISA detection limits from 1 ng mL -1 ≲ c BSA ≲ 500 ng mL -1 . In addition to the increased sensitivity, broader detection range, and similar specificity, fd-FRS can be conducted in less than ≈30 min, compared to ≈4 h with ELISA. Thus, fd-FRS is shown to be a sensitive optical technique with potential to become an efficient diagnostic in the chemical and biomolecular sciences. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Tegbaru, Belete; Messele, Tsehaynesh; Wolday, Dawit; Meles, PhD Hailu; Tesema, Desalegn; Birhanu, Hiwot; Tesfaye, Girma; Bond, Kyle B; Martin, Robert; Rayfield, Mark A; Wuhib, Tadesse; Fekadu, Makonnen
2004-10-01
Five simple and rapid HIV antibody detection assays viz. Determine, Capillus, Oraquick, Unigold and Hemastrip were evaluated to examine their performance and to develop an alternative rapid test based testing algorithm for voluntary counseling and testing (VCT) in Ethiopia. All the kits were tested on whole blood, plasma and serum. The evaluation had three phases: Primary lab review, piloting at point of service and implementation. This report includes the results of the first two phases. A total of 2,693 specimens (both whole blood and plasma) were included in the evaluation. Results were compared to double Enzyme Linked Immuno-Sorbent Assay (ELISA) system. Discordant EIA results were resolved using Western Blot. The assays had very good sensitivities and specificities, 99-100%, at the two different phases of the evaluation. A 98-100% result agreement was obtained from those tested at VCT centers and National Referral Laboratory for AIDS (NRLA), in the quality control phase of the evaluation. A testing strategy yielding 100% [95% CI; 98.9-100.0] sensitivity was achieved by the sequential use of the three rapid test kits. Direct cost comparison showed serial testing algorithm reduces the cost of testing by over 30% compared to parallel testing in the current situation. Determine, Capillus/Oraquick (presence/absence of frefrigeration) and Unigold were recommended as screening, confirmation and tiebreaker tests, respectively.