Sample records for bpm upgrade prototype

  1. Results from the RF BPM Upgrade Prototype at the Advanced Photon Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, Anthony; Lill, Robert; Norum, Eric

    2006-11-20

    The Advanced Photon Source (APS), a third-generation synchrotron light source, has been in operation for 10 years. The monopulse radio frequency (RF) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field programmable gate array (FPGA) that performs the signal processing. A prototype systemmore » was constructed and is currently being evaluated. This paper presents the results obtained from laboratory and field tests of the prototype system.« less

  2. Results from the RF BPM upgrade prototype at the Advanced Photon Source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, A.; Lill, R.; Norum, E.

    2006-01-01

    The Advanced Photon Source (APS), a third-generation synchrotron light source, has been in operation for 10 years. The monopulse radio frequency (RF) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field programmable gate array (FPGA) that performs the signal processing. A prototype systemmore » was constructed and is currently being evaluated. This paper presents the results obtained from laboratory and field tests of the prototype system.« less

  3. Analog Signal Pre-Processing For The Fermilab Main Injector BPM Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, A. L.; Rapisarda, S. M.; Wendt, M.

    2006-11-20

    An analog signal pre-processing scheme was developed, in the framework of the Fermilab Main Injector Beam Position Monitor (BPM) Upgrade, to interface BPM pickup signals to the new digital receiver based read-out system. A key component is the 8-channel electronics module, which uses separate frequency-selective gain stages to acquire 53 MHz bunched proton and 2.5 MHz antiproton signals. Related hardware includes a filter and combiner box to sum pickup electrode signals in the tunnel. A controller module allows local/remote control of gain settings and activation of gain stages and supplies test signals. Theory of operation, system overview, and some designmore » details are presented, as well as first beam measurements of the prototype hardware.« less

  4. Analog signal pre-processing for the Fermilab Main Injector BPM upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, A.L.; Rapisarda, S.M.; Wendt, M.

    2006-05-01

    An analog signal pre-processing scheme was developed, in the framework of the Fermilab Main Injector Beam Position Monitor (BPM) Upgrade, to interface BPM pickup signals to the new digital receiver based read-out system. A key component is the 8-channel electronics module, which uses separate frequency selective gain stages to acquire 53 MHz bunched proton, and 2.5 MHz anti-proton signals. Related hardware includes a filter and combiner box to sum pickup electrode signals in the tunnel. A controller module allows local/remote control of gain settings and activation of gain stages, and supplies test signals. Theory of operation, system overview, and somemore » design details are presented, as well as first beam measurements of the prototype hardware.« less

  5. BPM Design and Impedance Considerations for a Rotatable Collimator for the LHC Collimation Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Jeffrey Claiborne; /SLAC; Keller, Lewis

    2010-08-26

    The Phase II upgrade to the LHC collimation system calls for complementing the 30 high robust Phase I graphite secondary collimators with 30 high Z Phase II collimators. This paper reports on BPM and impedance considerations and measurements of the integrated BPMs in the prototype rotatable collimator to be installed in the Super Proton Synchrotron (SPS) at CERN. The BPMs are necessary to align the jaws with the beam. Without careful design the beam impedance can result in unacceptable heating of the chamber wall or beam instabilities. The impedance measurements involve utilizing both a single displaced wire and two wiresmore » excited in opposite phase to disentangle the driving and detuning transverse impedances. Trapped mode resonances and longitudinal impedance are to also be measured and compared with simulations. These measurements, when completed, will demonstrate the device is fully operational and has the impedance characteristics and BPM performance acceptable for installation in the SPS.« less

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Sereno, N.; Yang, B.

    The Advanced Photon Source (APS) is currently in the preliminary design phase for the multi-bend achromat (MBA) lattice upgrade. Beam stability is critical for the MBA and will require long term drift defined as beam mo-tion over a seven-day timescale to be no more than 1 mi-cron at the insertion device locations and beam angle change no more than 0.25 micro-radian. Mechanical stabil-ity of beam position monitor (BPM) pickup electrodes mounted on insertion device vacuum chambers place a fun-damental limitation on long-term beam stability for inser-tion device beamlines. We present the design and imple-mentation of prototype mechanical motion system (MMS)more » instrumentation for quantifying this type of motion specif-ically in the APS accelerator tunnel and experiment hall floor under normal operating conditions. The MMS pres-ently provides critical position information on the vacuum chamber and BPM support systems. Initial results of the R&D prototype systems have demonstrated that the cham-ber movements far exceed the long-term drift tolerance specified for the APS Upgrade MBA storage ring.« less

  7. APS Storage Ring Monopulse RF BPM Upgrade

    NASA Astrophysics Data System (ADS)

    Lill, R.; Pietryla, A.; Norum, E.; Lenkszus, F.

    2004-11-01

    The Advanced Photon Source (APS) is a third-generation synchrotron light source in its ninth year of operation. The storage ring monopulse radio frequency (rf) beam position monitor (BPM) was designed to measure single-turn and multi-turn beam positions for operations and machine physics studies. Many of the components used in the original design are obsolete and costly to replace. In this paper we present a proposal to upgrade the monopulse rf BPMs in which the existing system hardware is repartitioned and the aging data acquisition system is replaced. By replacing only the data acquisition system, we will demonstrate a cost-effective approach to improved beam stability, reliability, and enhanced postmortem capabilities. An eight-channel ADC/digitizer VXI board with sampling rate of up to 105 MHz (per channel) and 14-bit resolution coupled with a field-programmable gate array and embedded central processing will provide the flexibility to revitalize this system for another decade of operation. We will discuss the upgrade system specifications, design, and prototype test results.

  8. Upgrade of BPM Electronics for the SPring-8 Storage Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, Shigeki; Fujita, Takahiro; Shoji, Masazumi

    2006-11-20

    SPring-8, a 3rd generation synchrotron light source, has operated since 1997. Improvement of BPM performance is required as a part of upgrading activities of the storage ring as a light source. We have developed new electronics circuits for signal processing of the storage ring BPM, with target performance of sub-{mu}m range resolution with sufficiently fast measurement speed and good long-term stability. A set of the new circuits consists of multiplexers, an RF amplifier, a mixer, an IF amplifier, and a local oscillator for analog signal processing. The IF amplifier outputs are sampled with 16-bit 2-MSPS ADC on ADC boards andmore » the data are sent to a DSP board. The sampled data are processed and converted to position information in the DSP. A multiplexing method was employed to have a better stability of the performance by cancellation of variation common to each channel. Evaluation of the performance by using a prototype shows that position resolution well into the sub-{mu}m range has been achieved with a bandwidth of 1 kHz, and long-term stability of within 1 {mu}m has also been achieved.« less

  9. Status of the ATF Damping Ring BPM Upgrade Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briegel, C.; /Fermilab; Eddy, N.

    2011-12-01

    A substantial upgrade of the beam position monitors (BPM) at the ATF (Accelerator Test Facility) damping ring is currently in progress. Implementing digital read-out signal processing techniques in line with an optimized, low-noise analog downconverter, a resolution well below 1 mum could be demonstrated at 20 (of 96) upgraded BPM stations. The narrowband, high resolution BPM mode permits investigation of all types of non-linearities, imperfections and other obstacles in the machine which may limit the very low target aimed vertical beam emittance of < 2 pm. The technical status of the project, first beam measurements and an outlook to it'smore » finalization are presented.« less

  10. Diagnostics Upgrades for Investigations of HOM Effects in TESLA-type SCRF Cavities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lumpkin, A. H.; Edstrom Jr., D.; Ruan, J.

    We describe the upgrades to diagnostic capabilities on the Fermilab Accelerator Science and Technology (FAST) electron linear accelerator that will allow investigations of the effects of high-order modes (HOMs) in SCRF cavities on macropulse-average beam quality. We examine the dipole modes in the first pass-band generally observed in the 1.6-1.9 GHz regime for TESLA-type SCRF cavities due to uniform transverse beam offsets of the electron beam. Such cavities are the basis of the accelerators such as the European XFEL and the proposed MaRIE XFEL facility. Preliminary HOM detector data, prototype BPM test data, and first framing camera OTR data withmore » ~20- micron spatial resolution at 250 pC per bunch will be presented.« less

  11. High resolution upgrade of the ATF damping ring BPM system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Terunuma, N.; Urakawa, J.; /KEK, Tsukuba

    2008-05-01

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished in its first stage, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital downconversion techniques, digital signal processing, and also tests a new automatic gain error correction schema. The technical concept and realization, as well as preliminary results of beam studies are presented.

  12. PAL-XFEL cavity beam position monitor pick-up design and beam test

    NASA Astrophysics Data System (ADS)

    Lee, Sojeong; Park, Young Jung; Kim, Changbum; Kim, Seung Hwan; Shin, Dong Cheol; Han, Jang-Hui; Ko, In Soo

    2016-08-01

    As an X-ray Free Electron Laser, PAL-XFEL is about to start beam commissioning. X-band cavity beam position monitor (BPM) is used in the PAL-XFEL undulator beam line. Prototypes of cavity BPM pick-up were designed and fabricated to test the RF characteristics. Also, the beam test of a cavity BPM pick-up was done in the Injector Test Facility (ITF). In the beam test, the raw signal properties of the cavity BPM pick-up were measured at a 200 pC bunch charge. According to the RF test and beam test results, the prototype cavity BPM pick-up design was confirmed to meet the requirements of the PAL-XFEL cavity BPM system.

  13. Design and cold test of S-BAND cavity BPM for HLS

    NASA Astrophysics Data System (ADS)

    Luo, Qing; Sun, BaoGen; Jia, QiKa; He, DuoHui; Fang, Jia

    2011-12-01

    An S-band cavity BPM is designed for a new injector in National Synchrotron Radiation Laboratory. A re-entrant position cavity is tuned to the TM110 mode as position cavity. Cut-through waveguides are used as pickups to suppress the monopole signal. Theoretical resolution of this design is 31 nm. A prototype cavity BPM system is manufactured for off-line cold tests. The wire scanning method is used to calibrate the BPM and estimate the performance of the on-line BPM system. A cross-talk problem has been detected during the cold test. Racetrack cavity BPM design can be used to suppress the cross-talk. With the nonlinear effect being ignored, transform matrix can be used to correct cross-talk. Analysis of cold test results shows that the position resolution of prototype BPM is better than 3 μm.

  14. BPMs with Precise Alignment for TTF2

    NASA Astrophysics Data System (ADS)

    Noelle, D.; Priebe, G.; Wendt, M.; Werner, M.

    2004-11-01

    Design and technology of the new, standardized BPM-system for the warm sections of the TESLA Test Facility phase II (TTF2) are presented. Stripline- and button-BPM pickups are read-out with an upgraded version of the AM/PM BPM-electronics of TTF1. The Stripline-BPMs are fixed inside the quadrupole magnets. A stretched wire measurement was used to calibrate the electrical axis of the BPM wrt. to the magnetic axis of the quadrupole.

  15. Status of the RF BPM upgrade at the Advanced Photon Source.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pietryla, A.; Bui, H.; Decker, G.

    2008-01-01

    The Advanced Photon Source (APS),a third-generation synchrotron light source, has been in operation for eleven years. The monopulse radio frequency (rf) beam position monitor (BPM) is one of three BPM types now employed in the storage ring at the APS. It is a broadband (10 MHz) system designed to measure single-turn and multi-turn beam positions, but it suffers from an aging data acquisition system. The replacement BPM system retains the existing monopulse receivers and replaces the data acquisition system with high-speed analog-to-digital converters (ADCs) and a field-programmable gate array (FPGA) that performs the signal processing. A first-article system has beenmore » constructed and is currently being evaluated. This paper presents the results of testing of the first-article system as well as the progress made in other areas of this upgrade effort.« less

  16. High Resolution BPM Upgrade for the ATF Damping Ring at KEK

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eddy, N.; Briegel, C.; Fellenz, B.

    2011-08-17

    A beam position monitor (BPM) upgrade at the KEK Accelerator Test Facility (ATF) damping ring has been accomplished, carried out by a KEK/FNAL/SLAC collaboration under the umbrella of the global ILC R&D effort. The upgrade consists of a high resolution, high reproducibility read-out system, based on analog and digital down-conversion techniques, digital signal processing, and also implements a new automatic gain error correction schema. The technical concept and realization as well as results of beam studies are presented. The next generation of linear colliders require ultra-low vertical emittance of <2 pm-rad. The damping ring at the KEK Accelerator Test Facilitymore » (ATF) is designed to demonstrate this mission critical goal. A high resolution beam position monitor (BPM) system for the damping ring is one of the key tools for realizing this goal. The BPM system needs to provide two distnict measurements. First, a very high resolution ({approx}100-200nm) closed-orbit measurement which is averaged over many turns and realized with narrowband filter techniques - 'narrowband mode'. This is needed to monitor and steer the beam along an optimum orbit and to facilitate beam-based alignment to minimize non-linear field effects. Second, is the ability to make turn by turn (TBT) measurements to support optics studies and corrections necessary to achieve the design performance. As the TBT measurement necessitates a wider bandwidth, it is often referred to as 'wideband mode'. The BPM upgrade was initiated as a KEK/SLAC/FNAL collaboration in the frame of the Global Design Initiative of the International Linear Collider. The project was realized and completed using Japan-US funds with Fermilab as the core partner.« less

  17. Process-aware EHR BPM systems: two prototypes and a conceptual framework.

    PubMed

    Webster, Charles; Copenhaver, Mark

    2010-01-01

    Systematic methods to improve the effectiveness and efficiency of electronic health record-mediated processes will be key to EHRs playing an important role in the positive transformation of healthcare. Business process management (BPM) systematically optimizes process effectiveness, efficiency, and flexibility. Therefore BPM offers relevant ideas and technologies. We provide a conceptual model based on EHR productivity and negative feedback control that links EHR and BPM domains, describe two EHR BPM prototype modules, and close with the argument that typical EHRs must become more process-aware if they are to take full advantage of BPM ideas and technology. A prediction: Future extensible clinical groupware will coordinate delivery of EHR functionality to teams of users by combining modular components with executable process models whose usability (effectiveness, efficiency, and user satisfaction) will be systematically improved using business process management techniques.

  18. Design and performance of the LCLS cavity BPM system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Norum, E.; Morrison, L.

    2008-01-01

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low- noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  19. Design and Performance of the LCLS Cavity BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.M.; Morrison, L.H.; Norum, W.E.

    2008-01-23

    In this paper we present the design of the beam position monitor (BPM) system for the LCLS undulator, which features a high-resolution X-band cavity BPM. Each BPM has a TM{sub 010} monopole reference cavity and a TM{sub 110} dipole cavity designed to operate at a center frequency of 11.384 GHz. The signal processing electronics features a low noise single-stage three-channel heterodyne receiver that has selectable gain and a phase locking local oscillator. We will discuss the system specifications, design, and prototype test results.

  20. Cavity BPM with Dipole-Mode-Selective Coupler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Zenghai; Johnson, Ronald; Smith, Stephen R.

    2006-06-21

    In this paper, we present a novel position sensitive signal pickup scheme for a cavity BPM. The scheme utilizes the H-plane of the waveguide to couple magnetically to the side of the cavity, which results in a selective coupling to the dipole mode and a total rejection of the monopole mode. This scheme greatly simplifies the BPM geometry and relaxes machining tolerances. We will present detailed numerical studies on such a cavity BPM, analyze its resolution limit and tolerance requirements for a nanometer resolution. Finally present the measurement results of a X-band prototype.

  1. A high resolution cavity BPM for the CLIC Test Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chritin, N.; Schmickler, H.; Soby, L.

    2010-08-01

    In frame of the development of a high resolution BPM system for the CLIC Main Linac we present the design of a cavity BPM prototype. It consists of a waveguide loaded dipole mode resonator and a monopole mode reference cavity, both operating at 15 GHz, to be compatible with the bunch frequencies at the CLIC Test Facility. Requirements, design concept, numerical analysis, and practical considerations are discussed.

  2. Linac coherent light source (LCLS) undulator RF BPM system.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.; Waldschmidt, G.; Morrison, L.

    2006-01-01

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, andmore » prototype test results.« less

  3. Linac Coherent Light Source Undulator RF BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lill, R.M.; Morrison, L.H.; Waldschmidt, G.J.

    2007-04-17

    The Linac Coherent Light Source (LCLS) will be the world's first x-ray free-electron laser (FEL) when it becomes operational in 2009. The LCLS is currently in the construction phase. The beam position monitor (BPM) system planned for the LCLS undulator will incorporate a high-resolution X-band cavity BPM system described in this paper. The BPM system will provide high-resolution measurements of the electron beam trajectory on a pulse-to-pulse basis and over many shots. The X-band cavity BPM size, simple fabrication, and high resolution make it an ideal choice for LCLS beam position detection. We will discuss the system specifications, design, andmore » prototype test results.« less

  4. Upgrade of beamline BL08B at Taiwan Light Source from a photon-BPM to a double-grating SGM beamline.

    PubMed

    Yuh, Jih Young; Lin, Shan Wei; Huang, Liang Jen; Fung, Hok Sum; Lee, Long Life; Chen, Yu Joung; Cheng, Chiu Ping; Chin, Yi Ying; Lin, Hong Ji

    2015-09-01

    During the last 20 years, beamline BL08B has been upgraded step by step from a photon beam-position monitor (BPM) to a testing beamline and a single-grating beamline that enables experiments to record X-ray photo-emission spectra (XPS) and X-ray absorption spectra (XAS) for research in solar physics, organic semiconductor materials and spinel oxides, with soft X-ray photon energies in the range 300-1000 eV. Demands for photon energy to extend to the extreme ultraviolet region for applications in nano-fabrication and topological thin films are increasing. The basic spherical-grating monochromator beamline was again upgraded by adding a second grating that delivers photons of energy from 80 to 420 eV. Four end-stations were designed for experiments with XPS, XAS, interstellar photoprocess systems (IPS) and extreme-ultraviolet lithography (EUVL) in the scheduled beam time. The data from these experiments show a large count rate in core levels probed and excellent statistics on background normalization in the L-edge adsorption spectrum.

  5. An Information System Development Method Connecting Business Process Modeling and its Experimental Evaluation

    NASA Astrophysics Data System (ADS)

    Okawa, Tsutomu; Kaminishi, Tsukasa; Kojima, Yoshiyuki; Hirabayashi, Syuichi; Koizumi, Hisao

    Business process modeling (BPM) is gaining attention as a measure of analysis and improvement of the business process. BPM analyses the current business process as an AS-IS model and solves problems to improve the current business and moreover it aims to create a business process, which produces values, as a TO-BE model. However, researches of techniques that connect the business process improvement acquired by BPM to the implementation of the information system seamlessly are rarely reported. If the business model obtained by BPM is converted into UML, and the implementation can be carried out by the technique of UML, we can expect the improvement in efficiency of information system implementation. In this paper, we describe a method of the system development, which converts the process model obtained by BPM into UML and the method is evaluated by modeling a prototype of a parts procurement system. In the evaluation, comparison with the case where the system is implemented by the conventional UML technique without going via BPM is performed.

  6. Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jang, Hyojae, E-mail: lkcom@ibs.re.kr; Jin, Hyunchang; Jang, Ji-Ho

    2016-02-15

    A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, developmentmore » of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.« less

  7. BEAM DIAGNOSTICS USING BPM SIGNALS FROM INJECTED AND STORED BEAMS IN A STORAGE RING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, G.M.; Shaftan; T.

    2011-03-28

    Many modern light sources are operating in top-off injection mode or are being upgraded to top-off injection mode. The storage ring always has the stored beam and injected beam for top-off injection mode. So the BPM data is the mixture of both beam positions and the injected beam position cannot be measured directly. We propose to use dedicated wide band BPM electronics in the NSLS II storage ring to retrieve the injected beam trajectory with the singular value decomposition (SVD) method. The beam position monitor (BPM) has the capability to measure bunch-by-bunch beam position. Similar electronics can be used tomore » measure the bunch-by-bunch beam current which is necessary to get the injection beam position. The measurement precision of current needs to be evaluated since button BPM sum signal has position dependence. The injected beam trajectory can be measured and monitored all the time without dumping the stored beam. We can adjust and optimize the injected beam trajectory to maximize the injection efficiency. We can also measure the storage ring acceptance by mapping the injected beam trajectory.« less

  8. Fermilab Recycler Ring BPM Upgrade Based on Digital Receiver Technology

    NASA Astrophysics Data System (ADS)

    Webber, R.; Crisp, J.; Prieto, P.; Voy, D.; Briegel, C.; McClure, C.; West, R.; Pordes, S.; Mengel, M.

    2004-11-01

    Electronics for the 237 BPMs in the Fermilab Recycler Ring have been upgraded from a log-amplifier based system to a commercially produced digitizer-digital down converter based system. The hardware consists of a pre-amplifier connected to a split-plate BPM, an analog differential receiver-filter module and an 8-channel 80-MHz digital down converter VME board. The system produces position and intensity with a dynamic range of 30 dB and a resolution of ±10 microns. The position measurements are made on 2.5-MHz bunched beam and barrier buckets of the un-bunched beam. The digital receiver system operates in one of six different signal processing modes that include 2.5-MHz average, 2.5-MHz bunch-by-bunch, 2.5-MHz narrow band, unbunched average, un-bunched head/tail and 89-kHz narrow band. Receiver data is acquired on any of up to sixteen clock events related to Recycler beam transfers and other machine activities. Data from the digital receiver board are transferred to the front-end CPU for position and intensity computation on an on-demand basis through the VME bus. Data buffers are maintained for each of the acquisition events and support flash, closed orbit and turn-by-turn measurements. A calibration system provides evaluation of the BPM signal path and application programs.

  9. Tevatron beam position monitor upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wolbers, Stephen; Banerjee, B.; Barker, B.

    2005-05-01

    The Tevatron Beam Position Monitor (BPM) readout electronics and software have been upgraded to improve measurement precision, functionality and reliability. The original system, designed and built in the early 1980's, became inadequate for current and future operations of the Tevatron. The upgraded system consists of 960 channels of new electronics to process analog signals from 240 BPMs, new front-end software, new online and controls software, and modified applications to take advantage of the improved measurements and support the new functionality. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiprotonmore » position measurements. Measurements using the new system are presented that demonstrate its improved resolution and overall performance.« less

  10. An Information System Development Method Combining Business Process Modeling with Executable Modeling and its Evaluation by Prototyping

    NASA Astrophysics Data System (ADS)

    Okawa, Tsutomu; Kaminishi, Tsukasa; Hirabayashi, Syuichi; Suzuki, Ryo; Mitsui, Hiroyasu; Koizumi, Hisao

    The business in the enterprise is closely related with the information system to such an extent that the business activities are difficult without the information system. The system design technique that considers the business process well, and that enables a quick system development is requested. In addition, the demand for the development cost is also severe than before. To cope with the current situation, the modeling technology named BPM(Business Process Management/Modeling)is drawing attention and becoming important as a key technology. BPM is a technology to model business activities as business processes and visualize them to improve the business efficiency. However, a general methodology to develop the information system using the analysis result of BPM doesn't exist, and a few development cases are reported. This paper proposes an information system development method combining business process modeling with executable modeling. In this paper we describe a guideline to support consistency of development and development efficiency and the framework enabling to develop the information system from model. We have prototyped the information system with the proposed method and our experience has shown that the methodology is valuable.

  11. Prototypes and system test stands for the Phase 1 upgrade of the CMS pixel detector

    DOE PAGES

    Hasegawa, S.

    2016-04-23

    The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is duemore » to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).« less

  12. High Resolution BPM for Linear Colliders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simon, C.; Chel, S.; Luong, M.

    2006-11-20

    A high resolution Beam Position Monitor (BPM) is necessary for the beam-based alignment systems of high energy and low emittance electron linacs. Such a monitor is developed in the framework of the European CARE/SRF programme, in a close collaboration between DESY and CEA/DSM/DAPNIA. This monitor is a radiofrequency re-entrant cavity, which can be used either at room or cryogenic temperature, in an environment where dust particle contamination has to be avoided, such as superconducting cavities in a cryomodule. A first prototype of a re-entrant BPM has already delivered measurements at 2K. inside the first cryomodule (ACC1) on the TESLA Testmore » Facility 2 (TTF2). The performances of this BPM are analyzed both experimentally and theoretically, and the limitations of this existing system clearly identified. A new cavity and new electronics have been designed in order to improve the position resolution down to 1 {mu}m and the damping time down to 10 ns.« less

  13. MWPC prototyping and performance test for the STAR inner TPC upgrade

    NASA Astrophysics Data System (ADS)

    Shen, Fuwang; Wang, Shuai; Kong, Fangang; Bai, Shiwei; Li, Changyu; Videbæk, Flemming; Xu, Zhangbu; Zhu, Chengguang; Xu, Qinghua; Yang, Chi

    2018-07-01

    A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. The test results show that the constructed iTPC prototype meets all project requirements.

  14. ETHERNET BASED EMBEDDED SYSTEM FOR FEL DIAGNOSTICS AND CONTROLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jianxun Yan; Daniel Sexton; Steven Moore

    2006-10-24

    An Ethernet based embedded system has been developed to upgrade the Beam Viewer and Beam Position Monitor (BPM) systems within the free-electron laser (FEL) project at Jefferson Lab. The embedded microcontroller was mounted on the front-end I/O cards with software packages such as Experimental Physics and Industrial Control System (EPICS) and Real Time Executive for Multiprocessor System (RTEMS) running as an Input/Output Controller (IOC). By cross compiling with the EPICS, the RTEMS kernel, IOC device supports, and databases all of these can be downloaded into the microcontroller. The first version of the BPM electronics based on the embedded controller wasmore » built and is currently running in our FEL system. The new version of BPM that will use a Single Board IOC (SBIOC), which integrates with an Field Programming Gate Array (FPGA) and a ColdFire embedded microcontroller, is presently under development. The new system has the features of a low cost IOC, an open source real-time operating system, plug&play-like ease of installation and flexibility, and provides a much more localized solution.« less

  15. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.

    2015-11-19

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the referencemore » cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2/3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Lastly, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.« less

  16. Long bunch trains measured using a prototype cavity beam position monitor for the Compact Linear Collider

    NASA Astrophysics Data System (ADS)

    Cullinan, F. J.; Boogert, S. T.; Farabolini, W.; Lefevre, T.; Lunin, A.; Lyapin, A.; Søby, L.; Towler, J.; Wendt, M.

    2015-11-01

    The Compact Linear Collider (CLIC) requires beam position monitors (BPMs) with 50 nm spatial resolution for alignment of the beam line elements in the main linac and beam delivery system. Furthermore, the BPMs must be able to make multiple independent measurements within a single 156 ns long bunch train. A prototype cavity BPM for CLIC has been manufactured and tested on the probe beam line at the 3rd CLIC Test Facility (CTF3) at CERN. The transverse beam position is determined from the electromagnetic resonant modes excited by the beam in the two cavities of the pickup, the position cavity and the reference cavity. The mode that is measured in each cavity resonates at 15 GHz and has a loaded quality factor that is below 200. Analytical expressions for the amplitude, phase and total energy of signals from long trains of bunches have been derived and the main conclusions are discussed. The results of the beam tests are presented. The variable gain of the receiver electronics has been characterized using beam excited signals and the form of the signals for different beam pulse lengths with the 2 /3 ns bunch spacing has been observed. The sensitivity of the reference cavity signal to charge and the horizontal position signal to beam offset have been measured and are compared with theoretical predictions based on laboratory measurements of the BPM pickup and the form of the resonant cavity modes as determined by numerical simulation. Finally, the BPM was calibrated so that the beam position jitter at the BPM location could be measured. It is expected that the beam jitter scales linearly with the beam size and so the results are compared to predicted values for the latter.

  17. Successive approximation algorithm for beam-position-monitor-based LHC collimator alignment

    NASA Astrophysics Data System (ADS)

    Valentino, Gianluca; Nosych, Andriy A.; Bruce, Roderik; Gasior, Marek; Mirarchi, Daniele; Redaelli, Stefano; Salvachua, Belen; Wollmann, Daniel

    2014-02-01

    Collimators with embedded beam position monitor (BPM) button electrodes will be installed in the Large Hadron Collider (LHC) during the current long shutdown period. For the subsequent operation, BPMs will allow the collimator jaws to be kept centered around the beam orbit. In this manner, a better beam cleaning efficiency and machine protection can be provided at unprecedented higher beam energies and intensities. A collimator alignment algorithm is proposed to center the jaws automatically around the beam. The algorithm is based on successive approximation and takes into account a correction of the nonlinear BPM sensitivity to beam displacement and an asymmetry of the electronic channels processing the BPM electrode signals. A software implementation was tested with a prototype collimator in the Super Proton Synchrotron. This paper presents results of the tests along with some considerations for eventual operation in the LHC.

  18. Diagnostic Systems Plan for the Advanced Light Source Top-OffUpgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barry, Walter; Chin, Mike; Robin, David

    2005-05-10

    The Advanced Light Source (ALS) will soon be upgraded to enable top-off operations [1], in which electrons are quasi-continuously injected to produce constant stored beam current. The upgrade is structured in two phases. First, we will upgrade our injector from 1.5 GeV to 1.9 GeV to allow full energy injection and will start top-off operations. In the second phase, we will upgrade the Booster Ring (BR) with a bunch cleaning system to allow high bunch purity top-off injection. A diagnostics upgrade will be crucial for success in both phases of the top-off project, and our plan for it is describedmore » in this paper. New booster ring diagnostics will include updated beam position monitor (BPM) electronics, a tune monitoring system, and a new scraper. Two new synchrotron light monitors and a beam stop will be added to the booster-to-storage ring transfer line (BTS), and all the existing beam current monitors along the accelerator chain will be integrated into a single injection efficiency monitoring application. A dedicated bunch purity monitor will be installed in the storage ring (SR). Together, these diagnostic upgrades will enable smooth commissioning of the full energy injector and a quick transition to high quality top-off operation at the ALS.« less

  19. Study of the dE/dx resolution of a GEM Readout Chamber prototype for the upgrade of the ALICE TPC

    NASA Astrophysics Data System (ADS)

    Mathis, Andreas

    2018-02-01

    The ALICE Collaboration is planning a major upgrade of its central barrel detectors to be able to cope with the increased LHC luminosity beyond 2020. For the TPC, this implies a replacement of the currently used gated MWPCs (Multi-Wire Proportional Chamber) by GEM (Gas Electron Multiplier) based readout chambers. In order to prove, that the present particle identification capabilities via measurement of the specific energy loss are retained after the upgrade, a prototype of the ALICE IROC (Inner Readout Chamber) has been evaluated in a test beam campaign at the CERN PS. The dE/dx resolution of the prototype has been proven to be fully compatible with the current MWPCs.

  20. MWPC prototyping and performance test for the STAR inner TPC upgrade

    DOE PAGES

    Shen, Fuwang; Wang, Shuai; Kong, Fangang; ...

    2018-04-16

    A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test resultsmore » show that the constructed iTPC prototype meets all project requirements.« less

  1. MWPC prototyping and performance test for the STAR inner TPC upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, Fuwang; Wang, Shuai; Kong, Fangang

    A new prototype of STAR inner Time Projection Chamber (iTPC) MWPC sector has been fabricated and tested in an X-ray test system. The wire chamber built at Shandong University has a wire tension precision better than 6% and wire pitch precision better than 10 μm. The gas gain uniformity and energy resolution are measured to be better than 1% (RMS) and 20% (FWHM), respectively, using an 55Fe X-ray source. The iTPC upgrade project is to replace all 24 STAR TPC inner sectors as a crucial detector upgrade for the RHIC beam energy scan phase II program. Furthermore, the test resultsmore » show that the constructed iTPC prototype meets all project requirements.« less

  2. MWPC prototyping and testing for STAR inner TPC upgrade

    NASA Astrophysics Data System (ADS)

    Shen, F.; Wang, S.; Yang, C.; Xu, Q.

    2017-06-01

    STAR experiment at the Relativistic Heavy Ion Collider (RHIC) is upgrading the inner sectors of the Time Projection Chamber (iTPC). The iTPC upgrade project will increase the segmentation on the inner pad plane from 13 to 40 pad rows and renew the inner sector wire chambers. The upgrade will expand the TPC's acceptance from |η|<=1.0 to |η|<=1.5. Furthermore, the detector will have better acceptance for tracks with low momentum, as well as better resolution in both momentum and dE/dx for tracks of all momenta. The enhanced measurement capabilities of STAR-iTPC upgrade are crucial to the physics program of the Phase II of Beam Energy Scan (BES-II) at RHIC during 2019-2020, in particular the QCD phase transition study. In this proceedings, I will discuss the iTPC MWPC module fabrication and testing results from the first full size iTPC MWPC pre-prototype made at Shandong University.

  3. Measurements of a Newly Designed BPM for the Tevatron Electron Lens 2

    NASA Astrophysics Data System (ADS)

    Scarpine, V. E.; Kamerdzhiev, V.; Fellenz, B.; Olson, M.; Kuznetsov, G.; Kamerdzhiev, V.; Shiltsev, V. D.; Zhang, X. L.

    2006-11-01

    Fermilab has developed a second electron lens (TEL-2) for beam-beam compensation in the Tevatron as part of its Run II upgrade program. Operation of the beam position monitors (BPMs) in the first electron lens (TEL-1) showed a systematic transverse position difference between short proton bunches (2 ns sigma) and long electron pulses (˜1 us) of up to ˜1.5 mm. This difference was attributed to frequency dependence in the BPM system. The TEL-2 BPMs utilize a new, compact four-plate design with grounding strips between plates to minimize crosstalk. In-situ measurements of these new BPMs are made using a stretched wire pulsed with both proton and electron beam formats. In addition, longitudinal impedance measurements of the TEL-2 are presented. Signal processing algorithm studies indicate that the frequency-dependent transverse position offset may be reduced to ˜0.1 mm for the beam structures of interest.

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hasegawa, S.

    The CMS pixel phase-1 upgrade project replaces the current pixel detector with an upgraded system with faster readout electronics during the extended year-end technical stop of 2016/2017. New electronics prototypes for the system have been developed, and tests in a realistic environment for a comprehensive evaluation are needed. A full readout test stand with either the same hardware as used in the current CMS pixel detector or the latest prototypes of upgrade electronics has been built. The setup enables the observation and investigation of a jitter increase in the data line associated with trigger rate increases. This effect is duemore » to the way in which the clock and trigger distribution is implemented in CMS. A new prototype of the electronics with a PLL based on a voltage controlled quartz crystal oscillator (QPLL), which works as jitter filter, in the clock distribution path was produced. With the test stand, it was confirmed that the jitter increase is not seen with the prototype, and also good performance was confirmed at the expected detector operation temperature ($-$20 °C).« less

  5. Upgrading the Digital Electronics of the PEP-II Bunch Current Monitors at the Stanford Linear Accelerator Center

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kline, Josh; /SLAC

    2006-08-28

    The testing of the upgrade prototype for the bunch current monitors (BCMs) in the PEP-II storage rings at the Stanford Linear Accelerator Center (SLAC) is the topic of this paper. Bunch current monitors are used to measure the charge in the electron/positron bunches traveling in particle storage rings. The BCMs in the PEP-II storage rings need to be upgraded because components of the current system have failed and are known to be failure prone with age, and several of the integrated chips are no longer produced making repairs difficult if not impossible. The main upgrade is replacing twelve old (1995)more » field programmable gate arrays (FPGAs) with a single Virtex II FPGA. The prototype was tested using computer synthesis tools, a commercial signal generator, and a fast pulse generator.« less

  6. ICI Showcase House Prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2009-02-16

    Building Science Corporation collaborated with ICI Homes in Daytona Beach, FL on a 2008 prototype Showcase House that demonstrates the energy efficiency and durability upgrades that ICI currently promotes through its in-house efficiency program called EFactor.

  7. Measurements of a Newly Designed BPM for the Tevatron Electron Lens 2

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scarpine, V. E.; Kamerdzhiev, V.; Fellenz, B.

    2006-11-20

    Fermilab has developed a second electron lens (TEL-2) for beam-beam compensation in the Tevatron as part of its Run II upgrade program. Operation of the beam position monitors (BPMs) in the first electron lens (TEL-1) showed a systematic transverse position difference between short proton bunches (2 ns sigma) and long electron pulses ({approx}1 us) of up to {approx}1.5 mm. This difference was attributed to frequency dependence in the BPM system. The TEL-2 BPMs utilize a new, compact four-plate design with grounding strips between plates to minimize crosstalk. In-situ measurements of these new BPMs are made using a stretched wire pulsedmore » with both proton and electron beam formats. In addition, longitudinal impedance measurements of the TEL-2 are presented. Signal processing algorithm studies indicate that the frequency-dependent transverse position offset may be reduced to {approx}0.1 mm for the beam structures of interest.« less

  8. Longitudinal Gradient Dipole Magnet Prototype for APS at ANL

    DOE PAGES

    Kashikhin, V. S.; Borland, M.; Chlachidze, G.; ...

    2016-01-26

    We planned an upgrade of the Advanced Photon Source at Argonne National Laboratory (ANL). The main goal of the upgrade is to improve the storage ring performance based on more advanced optics. One of the key magnet system elements is bending dipole magnets having a field strength change along the electron beam path. Moreover, a prototype of one such longitudinal gradient dipole magnet has been designed, built, and measured in a collaborative effort of ANL and Fermilab. Our paper discusses various magnetic design options, the selected magnet design, and the fabrication technology. The prototype magnet has been measured by rotationalmore » coils, a stretched wire, and a Hall probe. Measurement results are discussed and compared with simulations.« less

  9. 8-channel prototype of SALT readout ASIC for Upstream Tracker in the upgraded LHCb experiment

    NASA Astrophysics Data System (ADS)

    Abellan Beteta, C.; Bugiel, S.; Dasgupta, R.; Firlej, M.; Fiutowski, T.; Idzik, M.; Kane, C.; Moron, J.; Swientek, K.; Wang, J.

    2017-02-01

    SALT is a new 128-channel readout ASIC for silicon strip detectors in the upgraded Upstream Tracker of the LHCb experiment. It will extract and digitise analogue signals from the sensor, perform digital processing and transmit serial output data. SALT is designed in CMOS 130 nm process and uses a novel architecture comprising of an analogue front-end and an ultra-low power (<0.5 mW) fast (40 MSps) sampling 6-bit ADC in each channel. An 8-channel prototype (SALT8), comprising all important functionalities was designed, fabricated and tested. A full 128-channel version was also submitted. The design and test results of the SALT8 prototype are presented showing its full functionality.

  10. New beam-position monitor system for upgraded Photon Factory storage ring.

    PubMed

    Haga, K; Honda, T; Tadano, M; Obina, T; Kasuga, T

    1998-05-01

    Accompanying the brilliance-upgrading project at the Photon Factory storage ring, the beam-position monitor (BPM) system has been renovated. The new system was designed to enable precise and fast measurements to correct the closed-orbit distortion (COD), as well as to feed back the orbit position during user runs. There are 42 BPMs newly installed, amounting to a total of 65 BPMs. All of the BPMs are calibrated on the test bench using a coaxially strung metallic wire. The measured electrical offsets are typically 200 micro m in both directions, which is 1/2-1/3 of those of the old-type BPMs. In the signal-processing system, PIN diode switches are employed in order to improve reliability. In the fastest mode, this system is capable of measuring COD within about 10 ms; this fast acquisition will allow fast suppression of the beam movement for frequencies up to 50 Hz using a global feedback system.

  11. Performance of a reentrant cavity beam position monitor

    NASA Astrophysics Data System (ADS)

    Simon, Claire; Luong, Michel; Chel, Stéphane; Napoly, Olivier; Novo, Jorge; Roudier, Dominique; Rouvière, Nelly; Baboi, Nicoleta; Mildner, Nils; Nölle, Dirk

    2008-08-01

    The beam-based alignment and feedback systems, essential operations for the future colliders, require high resolution beam position monitors (BPMs). In the framework of the European CARE/SRF program, a reentrant cavity BPM with its associated electronics was developed by the CEA/DSM/Irfu in collaboration with DESY. The design, the fabrication, and the beam test of this monitor are detailed within this paper. This BPM is designed to be inserted in a cryomodule, work at cryogenic temperature in a clean environment. It has achieved a resolution better than 10μm and has the possibility to perform bunch to bunch measurements for the x-ray free electron laser (X-FEL) and the International Linear Collider (ILC). Its other features are a small size of the rf cavity, a large aperture (78 mm), and an excellent linearity. A first prototype of a reentrant cavity BPM was installed in the free electron laser in Hamburg (FLASH), at Deutsches Elektronen-Synchrotron (DESY) and demonstrated its operation at cryogenic temperature inside a cryomodule. The second, installed, also, in the FLASH linac to be tested with beam, measured a resolution of approximately 4μm over a dynamic range ±5mm in single bunch.

  12. Development of CMOS pixel sensors for the upgrade of the ALICE Inner Tracking System

    NASA Astrophysics Data System (ADS)

    Molnar, L.

    2014-12-01

    The ALICE Collaboration is preparing a major upgrade of the current detector, planned for installation during the second long LHC shutdown in the years 2018-19, in order to enhance its low-momentum vertexing and tracking capability, and exploit the planned increase of the LHC luminosity with Pb beams. One of the cornerstones of the ALICE upgrade strategy is to replace the current Inner Tracking System in its entirety with a new, high resolution, low-material ITS detector. The new ITS will consist of seven concentric layers equipped with Monolithic Active Pixel Sensors (MAPS) implemented using the 0.18 μm CMOS technology of TowerJazz. In this contribution, the main key features of the ITS upgrade will be illustrated with emphasis on the functionality of the pixel chip. The ongoing developments on the readout architectures, which have been implemented in several fabricated prototypes, will be discussed. The operational features of these prototypes as well as the results of the characterisation tests before and after irradiation will also be presented.

  13. Improved compliance by BPM-driven workflow automation.

    PubMed

    Holzmüller-Laue, Silke; Göde, Bernd; Fleischer, Heidi; Thurow, Kerstin

    2014-12-01

    Using methods and technologies of business process management (BPM) for the laboratory automation has important benefits (i.e., the agility of high-level automation processes, rapid interdisciplinary prototyping and implementation of laboratory tasks and procedures, and efficient real-time process documentation). A principal goal of the model-driven development is the improved transparency of processes and the alignment of process diagrams and technical code. First experiences of using the business process model and notation (BPMN) show that easy-to-read graphical process models can achieve and provide standardization of laboratory workflows. The model-based development allows one to change processes quickly and an easy adaption to changing requirements. The process models are able to host work procedures and their scheduling in compliance with predefined guidelines and policies. Finally, the process-controlled documentation of complex workflow results addresses modern laboratory needs of quality assurance. BPMN 2.0 as an automation language to control every kind of activity or subprocess is directed to complete workflows in end-to-end relationships. BPMN is applicable as a system-independent and cross-disciplinary graphical language to document all methods in laboratories (i.e., screening procedures or analytical processes). That means, with the BPM standard, a communication method of sharing process knowledge of laboratories is also available. © 2014 Society for Laboratory Automation and Screening.

  14. Frequency of pacemaker malfunction associated with monopolar electrosurgery during pulse generator replacement or upgrade surgery.

    PubMed

    Lin, Yun; Melby, Daniel P; Krishnan, Balaji; Adabag, Selcuk; Tholakanahalli, Venkatakrishna; Li, Jian-Ming

    2017-08-01

    The aim of this study is to investigate the frequency of electrosurgery-related pacemaker malfunction. A retrospective study was conducted to investigate electrosurgery-related pacemaker malfunction in consecutive patients undergoing pulse generator (PG) replacement or upgrade from two large hospitals in Minneapolis, MN between January 2011 and January 2014. The occurrence of this pacemaker malfunction was then studied by using MAUDE database for all four major device vendors. A total of 1398 consecutive patients from 2 large tertiary referral centers in Minneapolis, MN undergoing PG replacement or upgrade surgery were retrospectively studied. Four patients (0.3% of all patients), all with pacemakers from St Jude Medical (2.8%, 4 of 142) had output failure or inappropriately low pacing rate below 30 bpm during electrosurgery, despite being programmed in an asynchronous mode. During the same period, 1174 cases of pacemaker malfunctions were reported on the same models in MAUDE database, 37 of which (3.2%) were electrosurgery-related. Twenty-four cases (65%) had output failure or inappropriate low pacing rate. The distribution of adverse events was loss of pacing (59.5%), reversion to backup pacing (32.4%), inappropriate low pacing rate (5.4%), and ventricular fibrillation (2.7%). The majority of these (78.5%) occurred during PG replacement at ERI or upgrade surgery. No electrosurgery-related malfunction was found in MAUDE database on 862 pacemaker malfunction cases during the same period from other vendors. Electrosurgery during PG replacement or upgrade surgery can trigger output failure or inappropriate low pacing rate in certain models of modern pacemakers. Cautions should be taken for pacemaker-dependent patients.

  15. A poloidal section neutron camera for MAST upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sangaroon, S.; Weiszflog, M.; Cecconello, M.

    2014-08-21

    The Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade) is intended as a demonstration of the physics viability of the Spherical Tokamak (ST) concept and as a platform for contributing to ITER/DEMO physics. Concerning physics exploitation, MAST Upgrade plasma scenarios can contribute to the ITER Tokamak physics particularly in the field of fast particle behavior and current drive studies. At present, MAST is equipped with a prototype neutron camera (NC). On the basis of the experience and results from previous experimental campaigns using the NC, the conceptual design of a neutron camera upgrade (NC Upgrade) is being developed. As part ofmore » the MAST Upgrade, the NC Upgrade is considered a high priority diagnostic since it would allow studies in the field of fast ions and current drive with good temporal and spatial resolution. In this paper, we explore an optional design with the camera array viewing the poloidal section of the plasma from different directions.« less

  16. MAPS development for the ALICE ITS upgrade

    NASA Astrophysics Data System (ADS)

    Yang, P.; Aglieri, G.; Cavicchioli, C.; Chalmet, P. L.; Chanlek, N.; Collu, A.; Gao, C.; Hillemanns, H.; Junique, A.; Kofarago, M.; Keil, M.; Kugathasan, T.; Kim, D.; Kim, J.; Lattuca, A.; Marin Tobon, C. A.; Marras, D.; Mager, M.; Martinengo, P.; Mazza, G.; Mugnier, H.; Musa, L.; Puggioni, C.; Rousset, J.; Reidt, F.; Riedler, P.; Snoeys, W.; Siddhanta, S.; Usai, G.; van Hoorne, J. W.; Yi, J.

    2015-03-01

    Monolithic Active Pixel Sensors (MAPS) offer the possibility to build pixel detectors and tracking layers with high spatial resolution and low material budget in commercial CMOS processes. Significant progress has been made in the field of MAPS in recent years, and they are now considered for the upgrades of the LHC experiments. This contribution will focus on MAPS detectors developed for the ALICE Inner Tracking System (ITS) upgrade and manufactured in the TowerJazz 180 nm CMOS imaging sensor process on wafers with a high resistivity epitaxial layer. Several sensor chip prototypes have been developed and produced to optimise both charge collection and readout circuitry. The chips have been characterised using electrical measurements, radioactive sources and particle beams. The tests indicate that the sensors satisfy the ALICE requirements and first prototypes with the final size of 1.5 × 3 cm2 have been produced in the first half of 2014. This contribution summarises the characterisation measurements and presents first results from the full-scale chips.

  17. Virtobot 2.0: the future of automated surface documentation and CT-guided needle placement in forensic medicine.

    PubMed

    Ebert, Lars Christian; Ptacek, Wolfgang; Breitbeck, Robert; Fürst, Martin; Kronreif, Gernot; Martinez, Rosa Maria; Thali, Michael; Flach, Patricia M

    2014-06-01

    In this paper we present the second prototype of a robotic system to be used in forensic medicine. The system is capable of performing automated surface documentation using photogrammetry, optical surface scanning and image-guided, post-mortem needle placement for tissue sampling, liquid sampling, or the placement of guide wires. The upgraded system includes workflow optimizations, an automatic tool-change mechanism, a new software module for trajectory planning and a fully automatic computed tomography-data-set registration algorithm. We tested the placement accuracy of the system by using a needle phantom with radiopaque markers as targets. The system is routinely used for surface documentation and resulted in 24 surface documentations over the course of 11 months. We performed accuracy tests for needle placement using a biopsy phantom, and the Virtobot placed introducer needles with an accuracy of 1.4 mm (±0.9 mm). The second prototype of the Virtobot system is an upgrade of the first prototype but mainly focuses on streamlining the workflow and increasing the level of automation and also has an easier user interface. These upgrades make the Virtobot a potentially valuable tool for case documentation in a scalpel-free setting that uses purely imaging techniques and minimally invasive procedures and is the next step toward the future of virtual autopsy.

  18. Online beam energy measurement of Beijing electron positron collider II linear accelerator

    NASA Astrophysics Data System (ADS)

    Wang, S.; Iqbal, M.; Liu, R.; Chi, Y.

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  19. Online beam energy measurement of Beijing electron positron collider II linear accelerator.

    PubMed

    Wang, S; Iqbal, M; Liu, R; Chi, Y

    2016-02-01

    This paper describes online beam energy measurement of Beijing Electron Positron Collider upgraded version II linear accelerator (linac) adequately. It presents the calculation formula, gives the error analysis in detail, discusses the realization in practice, and makes some verification. The method mentioned here measures the beam energy by acquiring the horizontal beam position with three beam position monitors (BPMs), which eliminates the effect of orbit fluctuation, and is much better than the one using the single BPM. The error analysis indicates that this online measurement has further potential usage such as a part of beam energy feedback system. The reliability of this method is also discussed and demonstrated in this paper.

  20. Research into display sharing techniques for distributed computing environments

    NASA Technical Reports Server (NTRS)

    Hugg, Steven B.; Fitzgerald, Paul F., Jr.; Rosson, Nina Y.; Johns, Stephen R.

    1990-01-01

    The X-based Display Sharing solution for distributed computing environments is described. The Display Sharing prototype includes the base functionality for telecast and display copy requirements. Since the prototype implementation is modular and the system design provided flexibility for the Mission Control Center Upgrade (MCCU) operational consideration, the prototype implementation can be the baseline for a production Display Sharing implementation. To facilitate the process the following discussions are presented: Theory of operation; System of architecture; Using the prototype; Software description; Research tools; Prototype evaluation; and Outstanding issues. The prototype is based on the concept of a dedicated central host performing the majority of the Display Sharing processing, allowing minimal impact on each individual workstation. Each workstation participating in Display Sharing hosts programs to facilitate the user's access to Display Sharing as host machine.

  1. Fabrication and Assembly Performance of the First 4.2 m MQXFA Magnet and Mechanical Model for the Hi-Lumi LHC Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Daniel W.; Ambrosio, Giorgio; Anderssen, Eric C.

    Here, the LHC accelerator research program (LARP), in collaboration with CERN and under the scope of the high luminosity upgrade of the Large Hadron Collider, is in the prototyping stage in the development of a 150 mm aperture high-field Nb 3Sn quadrupole magnet called MQXF. This magnet is mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D models within LARP, as well as in the more recent short (1.2 m magnetic length) MQXF model program. The MQXFA magnets are each 4.2 m magnetic length, and the first mechanical long model, MQXFA1M (using aluminum surrogatemore » coils), and MQXFAP1 prototype magnet (the first prototype with Nb 3Sn coils) have been assembled at the LBNL. In this paper, we summarize the tooling and the assembly processes, and discuss the mechanical performance of these first two assemblies, comparing strain gauge data with finite element model analysis, as well as the near-term plans for the long MQXF magnet program.« less

  2. Fabrication and Assembly Performance of the First 4.2 m MQXFA Magnet and Mechanical Model for the Hi-Lumi LHC Upgrade

    DOE PAGES

    Cheng, Daniel W.; Ambrosio, Giorgio; Anderssen, Eric C.; ...

    2018-01-30

    Here, the LHC accelerator research program (LARP), in collaboration with CERN and under the scope of the high luminosity upgrade of the Large Hadron Collider, is in the prototyping stage in the development of a 150 mm aperture high-field Nb 3Sn quadrupole magnet called MQXF. This magnet is mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D models within LARP, as well as in the more recent short (1.2 m magnetic length) MQXF model program. The MQXFA magnets are each 4.2 m magnetic length, and the first mechanical long model, MQXFA1M (using aluminum surrogatemore » coils), and MQXFAP1 prototype magnet (the first prototype with Nb 3Sn coils) have been assembled at the LBNL. In this paper, we summarize the tooling and the assembly processes, and discuss the mechanical performance of these first two assemblies, comparing strain gauge data with finite element model analysis, as well as the near-term plans for the long MQXF magnet program.« less

  3. SAMPA Chip: the New 32 Channels ASIC for the ALICE TPC and MCH Upgrades

    NASA Astrophysics Data System (ADS)

    Adolfsson, J.; Ayala Pabon, A.; Bregant, M.; Britton, C.; Brulin, G.; Carvalho, D.; Chambert, V.; Chinellato, D.; Espagnon, B.; Hernandez Herrera, H. D.; Ljubicic, T.; Mahmood, S. M.; Mjörnmark, U.; Moraes, D.; Munhoz, M. G.; Noël, G.; Oskarsson, A.; Osterman, L.; Pilyar, A.; Read, K.; Ruette, A.; Russo, P.; Sanches, B. C. S.; Severo, L.; Silvermyr, D.; Suire, C.; Tambave, G. J.; Tun-Lanoë, K. M. M.; van Noije, W.; Velure, A.; Vereschagin, S.; Wanlin, E.; Weber, T. O.; Zaporozhets, S.

    2017-04-01

    This paper presents the test results of the second prototype of SAMPA, the ASIC designed for the upgrade of read-out front end electronics of the ALICE Time Projection Chamber (TPC) and Muon Chamber (MCH). SAMPA is made in a 130 nm CMOS technology with 1.25 V nominal voltage supply and provides 32 channels, with selectable input polarity, and three possible combinations of shaping time and sensitivity. Each channel consists of a Charge Sensitive Amplifier, a semi-Gaussian shaper and a 10-bit ADC; a Digital Signal Processor provides digital filtering and compression capability. In the second prototype run both full chip and single test blocks were fabricated, allowing block characterization and full system behaviour studies. Experimental results are here presented showing agreement with requirements for both the blocks and the full chip.

  4. A Registry for Planetary Data Tools and Services

    NASA Astrophysics Data System (ADS)

    Hardman, S.; Cayanan, M.; Hughes, J. S.; Joyner, R.; Crichton, D.; Law, E.

    2018-04-01

    The PDS Engineering Node has upgraded a prototype Tool Registry developed by the International Planetary Data Alliance to increase the visibility and enhance functionality along with incorporating the registered tools into PDS data search results.

  5. The moving-ring field-reversed mirror prototype reactor

    NASA Astrophysics Data System (ADS)

    Smith, A. C., Jr.; Carlson, G. A.; Fleischmann, H. H.; Grossman, W., Jr.; Kammash, T.; Schultz, K. R.; Woodall, D. M.

    1981-03-01

    A prototype fusion reactor was designed based on magnetic field reversed plasma confinement. A set of physics, technology, and mechanical design criteria were developed in order to make this concept attractive. Six major criteria guide the commercial prototype design. The prototype must: (1) produce net electricity decisively P sub net 70% of P sub gross; (2) scale to an economical commercial plant and have small physical size; (3) have all features required of a correcial upgrade plant (H-3 breeding, etc.); (4) minimize exotic technology and maintenance complexity; (5) promise significantly lower safety hazards than fission plants (environmentally and socially acceptable); and (6) be modular in design to permit repetitive production of components.

  6. Monolithic active pixel sensor development for the upgrade of the ALICE inner tracking system

    NASA Astrophysics Data System (ADS)

    Aglieri, G.; Cavicchioli, C.; Chalmet, P. L.; Chanlek, N.; Collu, A.; Giubilato, P.; Hillemanns, H.; Junique, A.; Keil, M.; Kim, D.; Kim, J.; Kugathasan, T.; Lattuca, A.; Mager, M.; Marin Tobon, C. A.; Marras, D.; Martinengo, P.; Mattiazzo, S.; Mazza, G.; Mugnier, H.; Musa, L.; Pantano, D.; Puggioni, C.; Rousset, J.; Reidt, F.; Riedler, P.; Siddhanta, S.; Snoeys, W.; Usai, G.; van Hoorne, J. W.; Yang, P.; Yi, J.

    2013-12-01

    ALICE plans an upgrade of its Inner Tracking System for 2018. The development of a monolithic active pixel sensor for this upgrade is described. The TowerJazz 180 nm CMOS imaging sensor process has been chosen as it is possible to use full CMOS in the pixel due to the offering of a deep pwell and also to use different starting materials. The ALPIDE development is an alternative to approaches based on a rolling shutter architecture, and aims to reduce power consumption and integration time by an order of magnitude below the ALICE specifications, which would be quite beneficial in terms of material budget and background. The approach is based on an in-pixel binary front-end combined with a hit-driven architecture. Several prototypes have already been designed, submitted for fabrication and some of them tested with X-ray sources and particles in a beam. Analog power consumption has been limited by optimizing the Q/C of the sensor using Explorer chips. Promising but preliminary first results have also been obtained with a prototype ALPIDE. Radiation tolerance up to the ALICE requirements has also been verified.

  7. ALICE inner tracking system readout electronics prototype testing with the CERN "Giga Bit Transceiver''

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schambach, Joachim; Rossewij, M. J.; Sielewicz, K. M.

    The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.

  8. ALICE inner tracking system readout electronics prototype testing with the CERN "Giga Bit Transceiver''

    DOE PAGES

    Schambach, Joachim; Rossewij, M. J.; Sielewicz, K. M.; ...

    2016-12-28

    The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. Furthermore, this contribution describes laboratory and radiation testing results with this prototype board set.

  9. ALICE inner tracking system readout electronics prototype testing with the CERN ``Giga Bit Transceiver''

    NASA Astrophysics Data System (ADS)

    Schambach, J.; Rossewij, M. J.; Sielewicz, K. M.; Aglieri Rinella, G.; Bonora, M.; Ferencei, J.; Giubilato, P.; Vanat, T.

    2016-12-01

    The ALICE Collaboration is preparing a major detector upgrade for the LHC Run 3, which includes the construction of a new silicon pixel based Inner Tracking System (ITS). The ITS readout system consists of 192 readout boards to control the sensors and their power system, receive triggers, and deliver sensor data to the DAQ. To prototype various aspects of this readout system, an FPGA based carrier board and an associated FMC daughter card containing the CERN Gigabit Transceiver (GBT) chipset have been developed. This contribution describes laboratory and radiation testing results with this prototype board set.

  10. A contact-free respiration monitor for smart bed and ambulatory monitoring applications.

    PubMed

    Hart, Adam; Tallevi, Kevin; Wickland, David; Kearney, Robert E; Cafazzo, Joseph A

    2010-01-01

    The development of a contact-free respiration monitor has a broad range of clinical applications in the home and hospital setting. Current approaches suffer from a variety of problems including unreliability, low sensitivity, and high cost. This work describes a novel approach to contact-free respiration monitoring that addresses these shortcomings by employing a highly sensitive capacitance sensor to detect variations in capacitive coupling caused by breathing. A prototype system consisting of a synthetic-metallic pad, sensor electronics, and iPhone interface was built and its performance compared experimentally to the gold standard technique (Respiratory Inductance Plethysmography) on both a healthy volunteer and SimMan robotic mannequin. The prototype sensor effectively captured respiratory movements over breathing rates of 5-55 bpm; achieving an average spectral correlation of 0.88 (CI: 0.86-0.90) and 0.95 (CI: 0.95-0.96) to the gold standard using the SimMan and healthy volunteer respectively.

  11. [Impact of admission heart rate on short-term outcome of ST-elevation myocardial infarction patients].

    PubMed

    Zhang, Han; Yang, Yan-min; Zhu, Jun; Tan, Hui-qiong; Liu, Li-sheng

    2012-01-01

    To evaluate the impact of admission heart rate (HR) on 30-day all-cause death and cardiovascular events in Chinese patients with ST-elevation acute myocardial infarction (STEMI). A total of 7485 Chinese STEMI patients from a global randomized controlled trial (CREATE) database were divided into six groups by admission HR: < 60, 60 - 69, 70 - 79, 80 - 89, 90 - 99 and ≥ 100 bpm. The primary outcome was 30-day all-cause death; the secondary outcomes were the composite of 30-day all-cause death, reinfarction, cardiogenic shock or deadly arrhythmia. Admission glucose level, proportion of female gender, incidence of anterior myocardial infarction, previous diabetes mellitus, hypertension and Killip level II-IV were significantly higher in patients with admission HR ≥ 90 bpm compared to 60 - 69 bpm group (P < 0.05). The 30-day mortality was lowest (6.3%) in the 60 - 69 bpm group and was 9.6% in HR < 60 bpm group (P < 0.05 vs. 60 - 69 bpm group). In patients with admission HR > 60 bpm, the 30-day mortality increased in proportion to higher admission HR: 8.1% in 70 - 79 bpm, 9.2% in 80 - 89 bpm, 12.6% in 90 - 99 bpm and 24.6% in ≥ 100 bpm groups (all P < 0.05 vs. 60 - 69 bpm group). The incidence of MACE was similar as that of 30-day mortality: 27.0% in < 60 bpm, 12.5% in 60 - 69 bpm, 13.7% in 70 - 79 bpm, 14.3% in 80 - 89 bpm, 17.5% in 90 - 99 bpm and 31.1% in ≥ 100 bpm groups. Multivariate analysis showed that the incidence of 30-day mortality positively correlated with the admission HR (P < 0.05) except in the patients with admission HR < 60 bpm (OR = 0.832, P = 0.299), the risk of joint endpoint events was higher in the patients with HR < 60 bpm (OR = 1.532, 95%CI: 1.201 - 1.954, P < 0.05), 90 - 99 bpm (OR = 1.436, 95%CI: 1.091 - 1.889, P < 0.05) or ≥ 100 bpm (OR = 1.893, 95%CI: 1.471 - 2.436, P < 0.001). Admission HR is an independent risk factor for short-term outcome in Chinese STEMI patients.

  12. PRELIMINARY TEST RESULTS OF A PROTOTYPE FAST KICKER FOR APS MBA UPGRADE

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yao, C.-Y.; Morrison, L.; Sun, X.

    The APS multi-bend achromatic (MBA) upgrade storage ring plans to support two bunch fill patterns: a 48-bunch and a 324-bunch. A “swap out” injection scheme is required. In order to provide the required kick to injected beam, to minimize the beam loss and residual oscillation of injected beam, and to minimize the perturbation to stored beam during injection, the rise, fall, and flat-top parts of the kicker pulse must be within a 16.9-ns interval. Stripline-type kickers are chosen for both injection and extraction. We developed a prototype kicker that supports a ±15kV differential pulse voltage. We performed high voltage discharge,more » TDR measurement, high voltage pulse test and beam test of the kicker. We report the final design of the fast kicker and the test results.« less

  13. A HIGH BANDWIDTH BIPOLAR POWER SUPPLY FOR THE FAST CORRECTORS IN THE APS UPGRADE*

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Ju; Sprau, Gary

    The APS Upgrade of a multi-bend achromat (MBA) storage ring requires a fast bipolar power supply for the fast correction magnets. The key performance requirement of the power supply includes a small-signal bandwidth of 10 kHz for the output current. This requirement presents a challenge to the design because of the high inductance of the magnet load and a limited input DC voltage. A prototype DC/DC power supply utilizing a MOSFET H-bridge circuit with a 500 kHz PWM has been developed and tested successfully. The prototype achieved a 10-kHz bandwidth with less than 3-dB attenuation for a signal 0.5% ofmore » the maximum operating current of 15 amperes. This paper presents the design of the power circuit, the PWM method, the control loop, and the test results.« less

  14. Design and implementation of wire tension measurement system for MWPCs used in the STAR iTPC upgrade

    DOE PAGES

    Wang, Xu; Shen, Fuwang; Wang, Shuai; ...

    2017-04-06

    The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which will be used in the TPC upgrade. The wire tension measurement system causes the wires to vibrate and then it measures the fundamental frequency of the oscillation via a laser based optical platform. The platform can scan the entire wire plane, automatically, in a single run and obtain the wire tension on each wire with high precision. In this paper,more » the details about the measurement method and the system setup will be described. In addition, the test results for a prototype MWPC to be used in the STAR-iTPC upgrade will be presented.« less

  15. Design and implementation of wire tension measurement system for MWPCs used in the STAR iTPC upgrade

    NASA Astrophysics Data System (ADS)

    Wang, Xu; Shen, Fuwang; Wang, Shuai; Feng, Cunfeng; Li, Changyu; Lu, Peng; Thomas, Jim; Xu, Qinghua; Zhu, Chengguang

    2017-07-01

    The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which will be used in the TPC upgrade. The wire tension measurement system causes the wires to vibrate and then it measures the fundamental frequency of the oscillation via a laser based optical platform. The platform can scan the entire wire plane, automatically, in a single run and obtain the wire tension on each wire with high precision. In this paper, the details about the measurement method and the system setup will be described. In addition, the test results for a prototype MWPC to be used in the STAR-iTPC upgrade will be presented.

  16. Developments towards the LHCb VELO upgrade

    NASA Astrophysics Data System (ADS)

    Cid Vidal, Xabier

    2016-09-01

    The Vertex Locator (VELO) is a silicon strip detector surrounding the interaction region of the LHCb experiment. The upgrade of the VELO is planned to be installed in 2019-2020, and the current detector will be replaced by a hybrid pixel system equipped with electronics capable of reading out at a rate of 40 MHz. The new detector is designed to withstand the radiation dose expected at an integrated luminosity of 50 fb-1. The detector will be composed of silicon pixel sensors, read out by the VeloPix ASIC that is being developed based on the TimePix/MediPix family. The prototype sensors for the VELO upgrade are being irradiated in five different facilities and the post-irradiation performance is being measured with testbeams, and in the lab. These proceedings present the VELO upgrade and briefly discuss the results of the sensor testing campaign.

  17. Open-Source Wax RepRap 3-D Printer for Rapid Prototyping Paper-Based Microfluidics.

    PubMed

    Pearce, J M; Anzalone, N C; Heldt, C L

    2016-08-01

    The open-source release of self-replicating rapid prototypers (RepRaps) has created a rich opportunity for low-cost distributed digital fabrication of complex 3-D objects such as scientific equipment. For example, 3-D printable reactionware devices offer the opportunity to combine open hardware microfluidic handling with lab-on-a-chip reactionware to radically reduce costs and increase the number and complexity of microfluidic applications. To further drive down the cost while improving the performance of lab-on-a-chip paper-based microfluidic prototyping, this study reports on the development of a RepRap upgrade capable of converting a Prusa Mendel RepRap into a wax 3-D printer for paper-based microfluidic applications. An open-source hardware approach is used to demonstrate a 3-D printable upgrade for the 3-D printer, which combines a heated syringe pump with the RepRap/Arduino 3-D control. The bill of materials, designs, basic assembly, and use instructions are provided, along with a completely free and open-source software tool chain. The open-source hardware device described here accelerates the potential of the nascent field of electrochemical detection combined with paper-based microfluidics by dropping the marginal cost of prototyping to nearly zero while accelerating the turnover between paper-based microfluidic designs. © 2016 Society for Laboratory Automation and Screening.

  18. Integration of the ATLAS FE-I4 Pixel Chip in the Mini Time Projection Chamber

    NASA Astrophysics Data System (ADS)

    Lopez-Thibodeaux, Mayra; Garcia-Sciveres, Maurice; Kadyk, John; Oliver-Mallory, Kelsey

    2013-04-01

    This project deals with development of readout for a Time Projection Chamber (TPC) prototype. This is a type of detector proposed for direct detection of dark matter (WIMPS) with direction information. The TPC is a gaseous charged particle tracking detector composed of a field cage and a gas avalanche detector. The latter is made of two Gas Electron Multipliers in series, illuminating a pixel readout integrated circuit, which measures the distribution in position and time of the output charge. We are testing the TPC prototype, filled with ArCO2 gas, using a Fe-55 x-ray source and cosmic rays. The present prototype uses an FE-I3 chip for readout. This chip was developed about 10 years ago and is presently in use within the ATLAS pixel detector at the LHC. The aim of this work is to upgrade the TPC prototype to use an FE-I4 chip. The FE-I4 has an active area of 336 mm^2 and 26880 pixels, over nine times the number of pixels in the FE-I3 chip, and an active area about six times as much. The FE-I4 chip represents the state of the art of pixel detector readout, and is presently being used to build an upgrade of the ATLAS pixel detector.

  19. Depleted fully monolithic CMOS pixel detectors using a column based readout architecture for the ATLAS Inner Tracker upgrade

    NASA Astrophysics Data System (ADS)

    Wang, T.; Barbero, M.; Berdalovic, I.; Bespin, C.; Bhat, S.; Breugnon, P.; Caicedo, I.; Cardella, R.; Chen, Z.; Degerli, Y.; Egidos, N.; Godiot, S.; Guilloux, F.; Hemperek, T.; Hirono, T.; Krüger, H.; Kugathasan, T.; Hügging, F.; Marin Tobon, C. A.; Moustakas, K.; Pangaud, P.; Schwemling, P.; Pernegger, H.; Pohl, D.-L.; Rozanov, A.; Rymaszewski, P.; Snoeys, W.; Wermes, N.

    2018-03-01

    Depleted monolithic active pixel sensors (DMAPS), which exploit high voltage and/or high resistivity add-ons of modern CMOS technologies to achieve substantial depletion in the sensing volume, have proven to have high radiation tolerance towards the requirements of ATLAS in the high-luminosity LHC era. DMAPS integrating fast readout architectures are currently being developed as promising candidates for the outer pixel layers of the future ATLAS Inner Tracker, which will be installed during the phase II upgrade of ATLAS around year 2025. In this work, two DMAPS prototype designs, named LF-Monopix and TJ-Monopix, are presented. LF-Monopix was fabricated in the LFoundry 150 nm CMOS technology, and TJ-Monopix has been designed in the TowerJazz 180 nm CMOS technology. Both chips employ the same readout architecture, i.e. the column drain architecture, whereas different sensor implementation concepts are pursued. The paper makes a joint description of the two prototypes, so that their technical differences and challenges can be addressed in direct comparison. First measurement results for LF-Monopix will also be shown, demonstrating for the first time a fully functional fast readout DMAPS prototype implemented in the LFoundry technology.

  20. FELIX: a PCIe based high-throughput approach for interfacing front-end and trigger electronics in the ATLAS Upgrade framework

    NASA Astrophysics Data System (ADS)

    Anderson, J.; Bauer, K.; Borga, A.; Boterenbrood, H.; Chen, H.; Chen, K.; Drake, G.; Dönszelmann, M.; Francis, D.; Guest, D.; Gorini, B.; Joos, M.; Lanni, F.; Lehmann Miotto, G.; Levinson, L.; Narevicius, J.; Panduro Vazquez, W.; Roich, A.; Ryu, S.; Schreuder, F.; Schumacher, J.; Vandelli, W.; Vermeulen, J.; Whiteson, D.; Wu, W.; Zhang, J.

    2016-12-01

    The ATLAS Phase-I upgrade (2019) requires a Trigger and Data Acquisition (TDAQ) system able to trigger and record data from up to three times the nominal LHC instantaneous luminosity. The Front-End LInk eXchange (FELIX) system provides an infrastructure to achieve this in a scalable, detector agnostic and easily upgradeable way. It is a PC-based gateway, interfacing custom radiation tolerant optical links from front-end electronics, via PCIe Gen3 cards, to a commodity switched Ethernet or InfiniBand network. FELIX enables reducing custom electronics in favour of software running on commercial servers. The FELIX system, the design of the PCIe prototype card and the integration test results are presented in this paper.

  1. Pixel sensors with slim edges and small pitches for the CMS upgrades for HL-LHC

    DOE PAGES

    Vernieri, Caterina; Bolla, Gino; Rivera, Ryan; ...

    2016-06-07

    Here, planar n-in-n silicon detectors with small pitches and slim edges are being investigated for the innermost layers of tracking devices for the foreseen upgrades of the LHC experiments. Sensor prototypes compatible with the CMS readout, fabricated by Sintef, were tested in the laboratory and with a 120 GeV/c proton beam at the Fermilab test beam facility before and after irradiation with up to 2 × 10 15 neq/cm 2 fluence. Preliminary results of the data analysis are presented.

  2. Safety of Landiolol Hydrochloride as a Premedication for Producing an Appropriate Heart Rate for Multidetector-Row Computed Tomography Coronary Angiography.

    PubMed

    Koyoshi, Rie; Shiga, Yuhei; Idemoto, Yoshiaki; Ueda, Yoko; Tashiro, Kohei; Kuwano, Takashi; Kitajima, Ken; Fujimi, Kanta; Kawamura, Akira; Ogawa, Masahiro; Miura, Shin-Ichiro

    2018-01-01

    We evaluated the safety of a bolus injection of landiolol hydrochloride, an ultrashort-acting β1-selective antagonist, as a premedication prior to multidetector-row computed tomography coronary angiography (CTA). The subjects consisted of 176 patients (M/F = 64:112, 67 ± 11 years) who had heart rate (HR) at rest ≥ 70 beats/min (bpm) and underwent CTA. Systolic/diastolic blood pressure (SBP/DBP) and HR were measured before and after the administration of landiolol. SBP/DBP and HR upon entry to the CT room were 136 ± 17/80 ± 11 mm Hg and 83 ± 10 bpm, respectively. HR was significantly reduced at the time of CTA scan (62 ± 7 bpm). Next, we divided the patients into three groups according to HR upon entry to the CT room: 70 - 79 bpm (n = 76), 80 - 89 bpm (n = 60) and ≥ 90 bpm (n = 40). HR at the time of CTA scan was significantly lower than that upon entry to the CT room in all three groups: 70 - 79 bpm (74 ± 3 bpm upon entry to the CT room to 61 ± 6 bpm at the time of CAT scan), 80 - 89 bpm (84 ± 3 to 63 ± 7 bpm) and ≥ 90 bpm (98 ± 6 to 65 ± 7 bpm). Although SBP/DBP was significantly decreased after the CTA scan (123 ± 18/72 ± 12 mm Hg), landiolol had no severe adverse events throughout CTA. In conclusion, a bolus injection of landiolol reduced HR by about 20 bpm without any severe adverse effects. Thus, a bolus injection of landiolol hydrochloride may be a suitable pretreatment for controlling HR in CTA.

  3. Scaffolding protein RanBPM and its interactions in diverse signaling pathways in health and disease.

    PubMed

    Das, Soumyadip; Haq, Saba; Ramakrishna, Suresh

    2018-04-01

    Ran-binding protein in the microtubule-organizing center (RanBPM) is an evolutionarily conserved, nucleocytoplasmic scaffolding protein involved in various cellular processes and several signal transduction pathways. RanBPM has a crucial role in mediating disease pathology by interacting with diverse proteins to regulate their functions. Previously, we compiled diverse cellular functions of RanBPM. Since then the functions of RanBPM have increased exponentially. In this article, we have updated the functions of RanBPM through its manifold interactions that have been investigated to date, according to their roles in protein stability, transcriptional activity, cellular development, neurobiology, and the cell cycle. Our review provides a complete guide on RanBPM interactors, the physiological role of RanBPM in cellular functions, and potential applications in disease therapeutics.

  4. Advance prototype silver ion water bactericide system

    NASA Technical Reports Server (NTRS)

    Jasionowski, W. J.; Allen, E. T.

    1974-01-01

    An advance prototype unit was designed and fabricated to treat anticipated fuel cell water. The unit is a single canister that contains a membrane-type prefilter and a silver bromide contacting bed. A seven day baseline simulated mission test was performed; the performance was satisfactory and the effluent water was within all specifications for potability. After random vibrations another seven day simulated mission test was performed, and results indicate that simulated launch vibrations have no effects on the design and performance of the advanced prototype. Bench tests and accelerated breadboard tests were conducted to define the characteristics of an upgraded model of the advance prototype unit which would have 30 days of operating capability. A preliminary design of a silver ion generator for the shuttle orbiter was also prepared.

  5. Effect of Nebivolol on MIBG Parameters and Exercise in Heart Failure with Normal Ejection Fraction.

    PubMed

    Messias, Leandro Rocha; Ferreira, Aryanne Guimarães; Miranda, Sandra Marina Ribeiro de; Teixeira, José Antônio Caldas; Azevedo, Jader Cunha de; Messias, Ana Carolina Nader Vasconcelos; Maróstica, Elisabeth; Mesquita, Claudio Tinoco

    2016-05-01

    More than 50% of the patients with heart failure have normal ejection fraction (HFNEF). Iodine-123 metaiodobenzylguanidine (123I-MIBG) scintigraphy and cardiopulmonary exercise test (CPET) are prognostic markers in HFNEF. Nebivolol is a beta-blocker with vasodilating properties. To evaluate the impact of nebivolol therapy on CPET and123I-MIBG scintigraphic parameters in patients with HFNEF. Twenty-five patients underwent 123I-MIBG scintigraphy to determine the washout rate and early and late heart-to-mediastinum ratios. During the CPET, we analyzed the systolic blood pressure (SBP) response, heart rate (HR) during effort and recovery (HRR), and oxygen uptake (VO2). After the initial evaluation, we divided our cohort into control and intervention groups. We then started nebivolol and repeated the tests after 3 months. After treatment, the intervention group showed improvement in rest SBP (149 mmHg [143.5-171 mmHg] versus 135 mmHg [125-151 mmHg, p = 0.016]), rest HR (78 bpm [65.5-84 bpm] versus 64.5 bpm [57.5-75.5 bpm, p = 0.028]), peak SBP (235 mmHg [216.5-249 mmHg] versus 198 mmHg [191-220.5 mmHg], p = 0.001), peak HR (124.5 bpm [115-142 bpm] versus 115 bpm [103.7-124 bpm], p= 0.043), HRR on the 1st minute (6.5 bpm [4.75-12.75 bpm] versus 14.5 bpm [6.7-22 bpm], p = 0.025) and HRR on the 2nd minute (15.5 bpm [13-21.75 bpm] versus 23.5 bpm [16-31.7 bpm], p = 0.005), but no change in peak VO2 and 123I-MIBG scintigraphic parameters. Despite a better control in SBP, HR during rest and exercise, and improvement in HRR, nebivolol failed to show a positive effect on peak VO2 and 123I-MIBG scintigraphic parameters. The lack of effect on adrenergic activity may be the cause of the lack of effect on functional capacity.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Xu; Shen, Fuwang; Wang, Shuai

    The STAR experiment at RHIC is planning to upgrade the Time Projection Chamber which lies at the heart of the detector. We have designed an instrument to measure the tension of the wires in the multi-wire proportional chambers (MWPCs) which will be used in the TPC upgrade. The wire tension measurement system causes the wires to vibrate and then it measures the fundamental frequency of the oscillation via a laser based optical platform. The platform can scan the entire wire plane, automatically, in a single run and obtain the wire tension on each wire with high precision. In this paper,more » the details about the measurement method and the system setup will be described. In addition, the test results for a prototype MWPC to be used in the STAR-iTPC upgrade will be presented.« less

  7. Hybrid Imaging for Extended Depth of Field Microscopy

    NASA Astrophysics Data System (ADS)

    Zahreddine, Ramzi Nicholas

    An inverse relationship exists in optical systems between the depth of field (DOF) and the minimum resolvable feature size. This trade-off is especially detrimental in high numerical aperture microscopy systems where resolution is pushed to the diffraction limit resulting in a DOF on the order of 500 nm. Many biological structures and processes of interest span over micron scales resulting in significant blurring during imaging. This thesis explores a two-step computational imaging technique known as hybrid imaging to create extended DOF (EDF) microscopy systems with minimal sacrifice in resolution. In the first step a mask is inserted at the pupil plane of the microscope to create a focus invariant system over 10 times the traditional DOF, albeit with reduced contrast. In the second step the contrast is restored via deconvolution. Several EDF pupil masks from the literature are quantitatively compared in the context of biological microscopy. From this analysis a new mask is proposed, the incoherently partitioned pupil with binary phase modulation (IPP-BPM), that combines the most advantageous properties from the literature. Total variation regularized deconvolution models are derived for the various noise conditions and detectors commonly used in biological microscopy. State of the art algorithms for efficiently solving the deconvolution problem are analyzed for speed, accuracy, and ease of use. The IPP-BPM mask is compared with the literature and shown to have the highest signal-to-noise ratio and lowest mean square error post-processing. A prototype of the IPP-BPM mask is fabricated using a combination of 3D femtosecond glass etching and standard lithography techniques. The mask is compared against theory and demonstrated in biological imaging applications.

  8. Bipyrimidine ruthenium(II) arene complexes: structure, reactivity and cytotoxicity.

    PubMed

    Betanzos-Lara, Soledad; Novakova, Olga; Deeth, Robert J; Pizarro, Ana M; Clarkson, Guy J; Liskova, Barbora; Brabec, Viktor; Sadler, Peter J; Habtemariam, Abraha

    2012-10-01

    The synthesis and characterization of complexes [(η(6)-arene)Ru(N,N')X][PF(6)], where arene is para-cymene (p-cym), biphenyl (bip), ethyl benzoate (etb), hexamethylbenzene (hmb), indane (ind) or 1,2,3,4-tetrahydronaphthalene (thn), N,N' is 2,2'-bipyrimidine (bpm) and X is Cl, Br or I, are reported, including the X-ray crystal structures of [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)I][PF(6)] and [(η(6)-etb)Ru(bpm)Cl][PF(6)]. Complexes in which N,N' is 1,10-phenanthroline (phen), 1,10-phenanthroline-5,6-dione or 4,7-diphenyl-1,10-phenanthroline (bathophen) were studied for comparison. The Ru(II) arene complexes undergo ligand-exchange reactions in aqueous solution at 310 K; their half-lives for hydrolysis range from 14 to 715 min. Density functional theory calculations on [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-p-cym)Ru(bpm)Br][PF(6)], [(η(6)-p-cym)Ru(bpm)I][PF(6)], [(η(6)-bip)Ru(bpm)Cl][PF(6)], [(η(6)-bip)Ru(bpm)Br][PF(6)] and [(η(6)-bip)Ru(bpm)I][PF(6)] suggest that aquation occurs via an associative pathway and that the reaction is thermodynamically favourable when the leaving ligand is I > Br ≈ Cl. pK (a)* values for the aqua adducts of the complexes range from 6.9 to 7.32. A binding preference for 9-ethylguanine (9-EtG) compared with 9-ethyladenine (9-EtA) was observed for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)], [(η(6)-hmb)Ru(bpm)Cl](+), [(η(6)-ind)Ru(bpm)Cl](+), [(η(6)-thn)Ru(bpm)Cl](+), [(η(6)-p-cym)Ru(phen)Cl](+) and [(η(6)-p-cym)Ru(bathophen)Cl](+) in aqueous solution at 310 K. The X-ray crystal structure of the guanine complex [(η(6)-p-cym)Ru(bpm)(9-EtG-N7)][PF(6)](2) shows multiple hydrogen bonding. Density functional theory calculations show that the 9-EtG adducts of all complexes are thermodynamically preferred compared with those of 9-EtA. However, the bmp complexes are inactive towards A2780 human ovarian cancer cells. Calf thymus DNA interactions for [(η(6)-p-cym)Ru(bpm)Cl][PF(6)] and [(η(6)-p-cym)Ru(phen)Cl][PF(6)] consist of weak coordinative, intercalative and monofunctional coordination. Binding to biomolecules such as glutathione may play a role in deactivating the bpm complexes.

  9. Resting Bradycardia, Enhanced Postexercise Heart Rate Recovery and Cardiorespiratory Fitness in Recreational Ballroom Dancers.

    PubMed

    Cruz, Carlos Janssen Gomes da; Molina, Guilherme Eckhardt; Porto, Luiz Guilherme Grossi; Junqueira, Luiz Fernando

    2017-09-01

    In a cross-sectional study design, we evaluated the resting heart rate (HR baseline ) and exercise and postexercise stress test-related chronotropic responses in male practitioners of recreational ballroom dancing (BD; n = 25, M age = 26.6 ± 6.1 years) compared to a control group of insufficiently active nondancers (CG; n = 25, M age = 25.9 ± 4.5 years). All participants underwent a submaximal exercise test. At 85% of the maximal predicted HR, the recovery protocol was started, and heart rate recovery (HRR) was recorded during 1-min intervals for 5 min. Compared with CG, BD showed lower HR baseline (70 beats per minute [bpm] vs. 62 bpm, respectively, U = 143, p < .05, ES = .46), lower preexercise HR (94 bpm vs. 86 bpm, U = 157, p < .05, ES = .42), longer exercise test duration (346 s vs. 420 s, U = 95.5, p < .05, ES = .59), and higher HRR for 5 min postexercise (U = 1.29-1.89, p < .05, ES = .33-.50) as follows: 1st min (32 bpm vs. 40 bpm), 2nd min (45 bpm vs. 53 bpm), 3rd min (51 bpm vs. 58 bpm), 4th min (55 bpm vs. 59 bpm), and 5th min (59 bpm vs. 63 bpm). The coefficient of HRR from the 1st min to the 5th min postexercise was similar in both groups (U = 229-311, p > .05, ES = < .10-.22). Heightened cardiovascular functional status characterized by favorable enhanced chronotropic dynamics appears to occur in practitioners of recreational ballroom dancing, which suggests that this modality of exercise may result in health benefits.

  10. Blood pressure measurement in obese patients: comparison between upper arm and forearm measurements.

    PubMed

    Pierin, Angela M G; Alavarce, Débora C; Gusmão, Josiane L; Halpern, Alfredo; Mion, Décio

    2004-06-01

    It is well known that blood pressure measurement with a standard 12-13 cm wide cuff is erroneous for large arms. To compare arm blood pressure measurements with an appropriate cuff and forearm blood pressure measurements (BPM) with a standard cuff, and both measurements by the Photopletismography (Finapres) method. One hundred and twenty-nine obese patients were studied (body mass index=40+/-7 kg/m2). The patients had three arm BPM taken by an automatic oscillometric device using an appropriate cuff and three forearm BPM with a standard cuff in the sitting position after a five-minute rest. Data were analysed by the analysis of variance. The correction values were obtained by the linear regression test. Systolic and diastolic arm BPM with an appropriate cuff were significantly lower (p<0.05) than forearm BPM with a standard cuff. The measurements obtained by Finapres were significantly lower (p<0.05) than those found for forearm systolic and diastolic blood pressures and upper arm diastolic blood pressure. The equation to correct BPM in forearm in obese patients with arm circumference between 32-44 cm was: systolic BPM=33.2+/-0.68 x systolic forearm BPM, and diastolic BPM=25.2+0.59 x forearm diastolic BPM. This study showed that forearm blood pressure measurement overestimates the values of arm blood pressure measurement. In addition, it is possible to correct forearm BPM with an equation.

  11. BPM 3.0

    NASA Astrophysics Data System (ADS)

    Scheer, August-Wilhelm; Klueckmann, Joerg

    Business Process Management (BPM) is an established management discipline. Since today’s organizations expect every employee to think and act like an entrepreneur, i.e., like a manager, BPM is also increasingly becoming part of everyday operations. But merely adopting a process-based approach across the enterprise is not enough to enable BPM at every level. What is needed is a combination of organizational forms and technologies that support distributed BPM initiatives while simultaneously consolidating them company-wide. Every employee must be empowered to model and optimize their own processes. At the same time, the entire BPM community needs a platform that brings together all the individual initiatives. This is the only way to leverage the full potential of process-oriented management. In the following article, the authors describe the trends in BPM development that are turning users into process managers and supporting the creation of a BPM community.

  12. Measurement and Compensation of BPM Chamber Motion in HLS

    NASA Astrophysics Data System (ADS)

    Li, J. W.; Sun, B. G.; Cao, Y.; Xu, H. L.; Lu, P.; Li, C.; Xuan, K.; Wang, J. G.

    2010-06-01

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS. The horizontal drifts of beam orbit have been really suppressed within 20μm without the compensation of BPM chamber motion in the runtime.

  13. A High Fidelity Driving Simulator as a Tool for Design and Evaluation of Highway Infrastructure Upgrades

    DOT National Transportation Integrated Search

    2007-05-01

    A rapid prototyping approach was used in the driving simulation laboratory at the Western Transportation Institute (WTI) to simulate approximately 22 miles of US 191 between the Big Sky Resort community and the northern mouth of the Gallatin Canyon. ...

  14. Searching for New Physics with Top Quarks and Upgrade to the Muon Spectrometer at ATLAS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwarz, Thomas Andrew

    2015-06-29

    Over the funding period of this award, my research has focused on searching for new physics with top quarks and in the Higgs sector. The highly energetic top quark events at the LHC are an excellent venue to search for new physics, as well as make standard model measurements. Further, the recent discovery of the Higgs boson motivates searching for new physics that could be associated with it. This one-year award has facilitated the beginning of my research program, which has resulted in four publications, several conference talks, and multiple leadership positions within physics groups. Additionally, we are contributing tomore » ATLAS upgrades and operations. As part of the Phase I upgrade, I have taken on the responsibility of the design, prototyping, and quality control of a signal packet router for the trigger electronics of the New Small Wheel. This is a critical component of the upgrade, as the router is the main switchboard for all trigger signals to track finding processors. I am also leading the Phase II upgrade of the readout electronics of the muon spectrometer, and have been selected as the USATLAS Level-2 manager of the Phase II upgrade of the muon spectrometer. The award has been critical in these contributions to the experiment.« less

  15. ProcessGene-Connect: SOA Integration between Business Process Models and Enactment Transactions of Enterprise Software Systems

    NASA Astrophysics Data System (ADS)

    Wasser, Avi; Lincoln, Maya

    In recent years, both practitioners and applied researchers have become increasingly interested in methods for integrating business process models and enterprise software systems through the deployment of enabling middleware. Integrative BPM research has been mainly focusing on the conversion of workflow notations into enacted application procedures, and less effort has been invested in enhancing the connectivity between design level, non-workflow business process models and related enactment systems such as: ERP, SCM and CRM. This type of integration is useful at several stages of an IT system lifecycle, from design and implementation through change management, upgrades and rollout. The paper presents an integration method that utilizes SOA for connecting business process models with corresponding enterprise software systems. The method is then demonstrated through an Oracle E-Business Suite procurement process and its ERP transactions.

  16. Optical Breath Gas Extravehicular Activity Sensor for the Advanced Portable Life Support System

    NASA Technical Reports Server (NTRS)

    Wood, William R.; Casias, Miguel E.; Pilgrim, Jeffrey S.; Chullen, Cinda; Campbell, Colin

    2016-01-01

    The function of the infrared gas transducer used during extravehicular activity (EVA) in the current space suit is to measure and report the concentration of carbon dioxide (CO2) in the ventilation loop. The next generation portable life support system (PLSS) requires highly accurate CO2 sensing technology with performance beyond that presently in use on the International Space Station extravehicular mobility unit (EMU). Further, that accuracy needs to be provided over the full operating pressure range of the suit (3 to 25 psia). Accommodation within space suits demands that optical sensors meet stringent size, weight, and power requirements. A laser diode (LD) sensor based on infrared absorption spectroscopy is being developed for this purpose by Vista Photonics, Inc. Version 1.0 prototype devices were delivered to NASA Johnson Space Center (JSC) in September 2011. The prototypes were upgraded with more sophisticated communications and faster response times to version 2.0 and delivered to JSC in July 2012. The sensors incorporate a laser diode based CO2 channel that also includes an incidental water vapor (humidity) measurement. The prototypes are controlled digitally with an field-programmable gate array microcontroller architecture. Based on the results of the iterative instrument development, further prototype development and testing of instruments were performed leveraging the lessons learned where feasible. The present development extends and upgrades the earlier hardware for the advanced PLSS 2.5 prototypes for testing at JSC. The prototypes provide significantly enhanced accuracy for water vapor measurement and eliminate wavelength drift affecting the earlier versions. Various improvements to the electronics and gas sampling are currently being advanced including the companion development of engineering development units that will ultimately be capable of radiation tolerance. The combination of low power electronics with the performance of a long wavelength laser spectrometer enables multi-gas sensors with significantly increased performance over that presently offered in the EMU.

  17. Measurement and Compensation of BPM Chamber Motion in HLS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J. W.; Sun, B. G.; Cao, Y.

    2010-06-23

    Significant horizontal drifts in the beam orbit in the storage ring of HLS (Hefei Light Source) have been seen for many years. What leads to the motion of Beam Position Monitor (BPM) chamber is thermal expansion mainly caused by the synchrotron light. To monitor the BPM chamber motions for all BPMs, a BPM chamber motion measurement system is built in real-time. The raster gauges are used to measure the displacements. The results distinctly show the relation between the BPM chamber motion and the beam current. To suppress the effect of BPM chamber motion, a compensation strategy is implemented at HLS.more » The horizontal drifts of beam orbit have been really suppressed within 20{mu}m without the compensation of BPM chamber motion in the runtime.« less

  18. Diagnosing Postural Tachycardia Syndrome: Comparison of Tilt Test versus Standing Hemodynamics

    PubMed Central

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2012-01-01

    Postural tachycardia syndrome (POTS) is characterized by increased heart rate (ΔHR) of ≥30 bpm with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of TILT and STAND testing. ΔHR values were analyzed at 5 min intervals. Receiver Operating Characteristics analysis was performed to determine optimal cut point values of ΔHR for both TILT and STAND. TILT produced larger ΔHR than STAND for all 5 min intervals from 5 min (38±3 bpm vs. 33±3 bpm; P=0.03) to 30 min (51±3 bpm vs. 38±3 bpm; P<0.001). Sensitivity (Sn) of the 30 bpm criterion was similar for all tests (TILT-10=93%, STAND-10=87%, TILT30=100%, and STAND30=93%). Specificity (Sp) of the 30 bpm criterion was less at both 10 and 30 min for TILT (TILT10=40%, TILT30=20%) than STAND (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for TILT (with lower specificity for POTS diagnosis) than STAND at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min TILT. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used. PMID:22931296

  19. Diagnosing postural tachycardia syndrome: comparison of tilt testing compared with standing haemodynamics.

    PubMed

    Plash, Walker B; Diedrich, André; Biaggioni, Italo; Garland, Emily M; Paranjape, Sachin Y; Black, Bonnie K; Dupont, William D; Raj, Satish R

    2013-01-01

    POTS (postural tachycardia syndrome) is characterized by an increased heart rate (ΔHR) of ≥30 bpm (beats/min) with symptoms related to upright posture. Active stand (STAND) and passive head-up tilt (TILT) produce different physiological responses. We hypothesized these different responses would affect the ability of individuals to achieve the POTS HR increase criterion. Patients with POTS (n=15) and healthy controls (n=15) underwent 30 min of tilt and stand testing. ΔHR values were analysed at 5 min intervals. ROC (receiver operating characteristic) analysis was performed to determine optimal cut point values of ΔHR for both tilt and stand. Tilt produced larger ΔHR than stand for all 5 min intervals from 5 min (38±3 bpm compared with 33±3 bpm; P=0.03) to 30 min (51±3 bpm compared with 38±3 bpm; P<0.001). Sn (sensitivity) of the 30 bpm criterion was similar for all tests (TILT10=93%, STAND10=87%, TILT30=100%, and STAND30=93%). Sp (specificity) of the 30 bpm criterion was less at both 10 and 30 min for tilt (TILT10=40%, TILT30=20%) than stand (STAND10=67%, STAND30=53%). The optimal ΔHR to discriminate POTS at 10 min were 38 bpm (TILT) and 29 bpm (STAND), and at 30 min were 47 bpm (TILT) and 34 bpm (STAND). Orthostatic tachycardia was greater for tilt (with lower Sp for POTS diagnosis) than stand at 10 and 30 min. The 30 bpm ΔHR criterion is not suitable for 30 min tilt. Diagnosis of POTS should consider orthostatic intolerance criteria and not be based solely on orthostatic tachycardia regardless of test used.

  20. Performance of the Prototype Readout System for the CMS Endcap Hadron Calorimeter Upgrade

    NASA Astrophysics Data System (ADS)

    Chaverin, Nate; Dittmann, Jay; Hatakeyama, Kenichi; Pastika, Nathaniel; CMS Collaboration

    2016-03-01

    The Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider (LHC) will upgrade the photodetectors and readout systems of the endcap hadron calorimeter during the technical stop scheduled for late 2016 and early 2017. A major milestone for this project was a highly successful testbeam run at CERN in August 2015. The testbeam run served as a full integration test of the electronics, allowing a study of the response of the preproduction electronics to the true detector light profile, as well as a test of the light yield of various new plastic scintillator materials. We present implications for the performance of the hadron calorimeter front-end electronics based on testbeam data, and we report on the production status of various components of the system in preparation for the upgrade.

  1. Heart rate at baseline influences the effect of ivabradine on cardiovascular outcomes in chronic heart failure: analysis from the SHIFT study.

    PubMed

    Böhm, Michael; Borer, Jeffrey; Ford, Ian; Gonzalez-Juanatey, Jose R; Komajda, Michel; Lopez-Sendon, Jose; Reil, Jan-Christian; Swedberg, Karl; Tavazzi, Luigi

    2013-01-01

    We analysed the effect of ivabradine on outcomes in heart failure (HF) patients on recommended background therapies with heart rates ≥75 bpm and <75 bpm in the SHIFT trial. A cut-off value of ≥75 bpm was chosen by the EMEA for approval for the use of ivabradine in chronic heart failure. The SHIFT population was divided by baseline heart rate ≥75 or <75 bpm. The effect of ivabradine was analysed for primary composite endpoint (cardiovascular death or HF hospitalization) and other endpoints. In the ≥75 bpm group, ivabradine reduced primary endpoint (HR 0.76, 95 % CI 0.68-0.85, P < 0.0001), all-cause mortality (HR 0.83, 95 % CI, 0.72-0.96, P = 0.0109), cardiovascular mortality (HR 0.83, 95 % CI, (0.71-0.97, P = 0.0166), HF death (HR 0.61, 95 % CI, 0.46-0.81, P < 0.0006), and HF hospitalization (HR 0.70, 95 % CI, 0.61-0.80, P < 0.0001). Risk reduction depended on heart rate after 28 days, with the best protection for heart rates <60 bpm or reductions >10 bpm. None of the endpoints was significantly reduced in the <75 bpm group, though there were trends for risk reductions in HF death and hospitalization for heart rate <60 bpm and reductions >10 bpm. Ivabradine was tolerated similarly in both groups. The effect of ivabradine on outcomes is greater in patients with heart rate ≥75 bpm with heart rates achieved <60 bpm or heart rate reductions >10 bpm predicting best risk reduction. Our findings emphasize the importance of identification of high-risk HF patients by high heart rates and their treatment with heart rate-lowering drugs such as ivabradine.

  2. A Study to Compare the Failure Rates of Current Space Shuttle Ground Support Equipment with the New Pathfinder Equipment and Investigate the Effect that the Proposed GSE Infrastructure Upgrade Might Have to Reduce GSE Infrastructure Failures

    NASA Technical Reports Server (NTRS)

    Kennedy, Barbara J.

    2004-01-01

    The purposes of this study are to compare the current Space Shuttle Ground Support Equipment (GSE) infrastructure with the proposed GSE infrastructure upgrade modification. The methodology will include analyzing the first prototype installation equipment at Launch PAD B called the "Pathfinder". This study will begin by comparing the failure rate of the current components associated with the "Hardware interface module (HIM)" at the Kennedy Space Center to the failure rate of the neW Pathfinder components. Quantitative data will be gathered specifically on HIM components and the PAD B Hypergolic Fuel facility and Hypergolic Oxidizer facility areas which has the upgraded pathfinder equipment installed. The proposed upgrades include utilizing industrial controlled modules, software, and a fiber optic network. The results of this study provide evidence that there is a significant difference in the failure rates of the two studied infrastructure equipment components. There is also evidence that the support staff for each infrastructure system is not equal. A recommendation to continue with future upgrades is based on a significant reduction of failures in the new' installed ground system components.

  3. Quality of life among patients after bilateral prophylactic mastectomy: a systematic review of patient-reported outcomes.

    PubMed

    Razdan, Shantanu N; Patel, Vishal; Jewell, Sarah; McCarthy, Colleen M

    2016-06-01

    Bilateral prophylactic mastectomy (BPM) is effective in reducing the risk of breast cancer in women with a well-defined family history of breast cancer or in women with BRCA 1 or 2 mutations. Evaluating patient-reported outcomes following BPM are thus essential for evaluating success of BPM from patient's perspective. Our systematic review aimed to: (1) identify studies describing health-related quality of life (HRQOL) in patients following BPM with or without reconstruction; (2) assess the effect of BPM with or without reconstruction on HRQOL; and (3) identify predictors of HRQOL post-BPM. We performed a systematic review of literature using the PRISMA guidelines. PubMed, Embase, PsycINFO, Web of Science, Scopus and Cochrane databases were searched. The initial search resulted in 1082 studies; 22 of these studies fulfilled our inclusion criteria. Post-BPM, patients are satisfied with the outcomes and report high psychosocial well-being and positive body image. Sexual well-being and somatosensory function are most negatively affected. Vulnerability, psychological distress and preoperative cancer distress are significant negative predictors of quality of life and body image post-BPM. There is a paucity of high-quality data on outcomes of different HRQOL domains post-BPM. Future studies should strive to use validated and breast-specific PRO instruments for measuring HRQOL. This will facilitate shared decision-making by enabling surgeons to provide evidence-based answers to women contemplating BPM.

  4. Towards a typology of business process management professionals: identifying patterns of competences through latent semantic analysis

    NASA Astrophysics Data System (ADS)

    Müller, Oliver; Schmiedel, Theresa; Gorbacheva, Elena; vom Brocke, Jan

    2016-01-01

    While researchers have analysed the organisational competences that are required for successful Business Process Management (BPM) initiatives, individual BPM competences have not yet been studied in detail. In this study, latent semantic analysis is used to examine a collection of 1507 BPM-related job advertisements in order to develop a typology of BPM professionals. This empirical analysis reveals distinct ideal types and profiles of BPM professionals on several levels of abstraction. A closer look at these ideal types and profiles confirms that BPM is a boundary-spanning field that requires interdisciplinary sets of competence that range from technical competences to business and systems competences. Based on the study's findings, it is posited that individual and organisational alignment with the identified ideal types and profiles is likely to result in high employability and organisational BPM success.

  5. Gum-compliant uncertainty propagations for Pu and U concentration measurements using the 1st-prototype XOS/LANL hiRX instrument; an SRNL H-Canyon Test Bed performance evaluation project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holland, Michael K.; O'Rourke, Patrick E.

    An SRNL H-Canyon Test Bed performance evaluation project was completed jointly by SRNL and LANL on a prototype monochromatic energy dispersive x-ray fluorescence instrument, the hiRX. A series of uncertainty propagations were generated based upon plutonium and uranium measurements performed using the alpha-prototype hiRX instrument. Data reduction and uncertainty modeling provided in this report were performed by the SRNL authors. Observations and lessons learned from this evaluation were also used to predict the expected uncertainties that should be achievable at multiple plutonium and uranium concentration levels provided instrument hardware and software upgrades being recommended by LANL and SRNL are performed.

  6. Dynamic performance of the beam position monitor support at the SSRF.

    PubMed

    Wang, Xiao; Cao, Yun; Du, Hanwen; Yin, Lixin

    2009-01-01

    Electron beam stability is very important for third-generation light sources, especially for the Shanghai Synchrotron Radiation Facility whose ground vibrations are much larger than those for other light sources. Beam position monitors (BPMs), used to monitor the position of the electron beam, require a greater stability than other mechanical structures. This paper concentrates on an investigation of the dynamic performance of the BPM support prototype. Modal and response analyses have been carried out by finite-element (FE) calculations and vibration measurements. Inconsistent results between calculation and measurement have motivated a change in the soft connections between the support and the ground from a ground bolt in the initial design to full grout. As a result the mechanical stability of the BPM support is greatly improved, showing an increase in the first eigenfrequency from 20.2 Hz to 50.2 Hz and a decrease in the ratio of the root-mean-square displacement (4-50 Hz) between the ground and the top of the support from 4.36 to 1.23 in the lateral direction. An example is given to show how FE analysis can guide the mechanical design and dynamic measurements (i.e. it is not just used as a verification method). Similar ideas can be applied to improve the stability of other mechanical structures.

  7. Design and implementation of a prototype with a standardized interface for transducers in ambient assisted living.

    PubMed

    Dorronzoro, Enrique; Gómez, Isabel; Medina, Ana Verónica; Gómez, José Antonio

    2015-01-29

    Solutions in the field of Ambient Assisted Living (AAL) do not generally use standards to implement a communication interface between sensors and actuators. This makes these applications isolated solutions because it is so difficult to integrate them into new or existing systems. The objective of this research was to design and implement a prototype with a standardized interface for sensors and actuators to facilitate the integration of different solutions in the field of AAL. Our work is based on the roadmap defined by AALIANCE, using motes with TinyOS telosb, 6LoWPAN, sensors, and the IEEE 21451 standard protocol. This prototype allows one to upgrade sensors to a smart status for easy integration with new applications and already existing ones. The prototype has been evaluated for autonomy and performance. As a use case, the prototype has been tested in a serious game previously designed for people with mobility problems, and its advantages and disadvantages have been analysed.

  8. Design and Implementation of a Prototype with a Standardized Interface for Transducers in Ambient Assisted Living

    PubMed Central

    Dorronzoro, Enrique; Gómez, Isabel; Medina, Ana Verónica; Gómez, José Antonio

    2015-01-01

    Solutions in the field of Ambient Assisted Living (AAL) do not generally use standards to implement a communication interface between sensors and actuators. This makes these applications isolated solutions because it is so difficult to integrate them into new or existing systems. The objective of this research was to design and implement a prototype with a standardized interface for sensors and actuators to facilitate the integration of different solutions in the field of AAL. Our work is based on the roadmap defined by AALIANCE, using motes with TinyOS telosb, 6LoWPAN, sensors, and the IEEE 21451 standard protocol. This prototype allows one to upgrade sensors to a smart status for easy integration with new applications and already existing ones. The prototype has been evaluated for autonomy and performance. As a use case, the prototype has been tested in a serious game previously designed for people with mobility problems, and its advantages and disadvantages have been analysed. PMID:25643057

  9. Development of a BPM Lock-In Diagnostic System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Richard Dickson

    2003-05-12

    A system has been developed for the acquisition and analysis of high rate, time coherent BPM data across the Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF). This system will allow the acquisition of Beam Position Monitor (BPM) position and intensity information at a rate in excess 7 KHz for approximately 200 BPMs in a time synchronous manner. By inducing minute sinusoidal transverse beam motion in the CEBAF injector, with known phase relative to the synchronized BPM acquisition, it is possible to derive several types of useful information. Analysis of the BPM intensity data, which is proportional to beam current,more » by beating the signal with an in-phase sinusoidal representation of the transverse kick can localize beam scraping to a particular BPM. Similarly, real-time optics information may be deduced with an analysis of BPM position data. This paper will detail the frequency lock-in technique applied and present status.« less

  10. Leap-frog-based BPM (LF-BPM) method for solving nanophotonic structures

    NASA Astrophysics Data System (ADS)

    Ayoub, Ahmad B.; Swillam, Mohamed A.

    2018-02-01

    In this paper, we propose an efficient approach to solve the BPM equation. By splitting the complex field into real and imaginary parts, the method is proved to be at least 30% faster than the conventional BPM. This method was tested on several optical components to test the accuracy.

  11. Preliminary evidence for good psychometric properties of the Norwegian version of the Brief Problems Monitor (BPM).

    PubMed

    Richter, Jörg

    2015-04-01

    Methods to assess intervention progress and outcome for frequent use are needed. To provide preliminary information about psychometric properties for the Norwegian version of the Brief Problems Monitor. Cronbach's alpha scores and intra-class correlation coefficients as indicators for internal consistency (reliability) and Pearson correlation coefficients between corresponding subscales of the long and short ASEBA form versions as well as multiple regression coefficients to explore the predictive power of the reduced item-set related to the corresponding scale-scores of the long version were calculated in large, representative data sets of Norwegian children and adolescents. Cronbach's alpha scores of the Norwegian version of the BPM subscales varied between 0.67 (attention BPM-youth) and 0.88 (attention BPM-teacher) and between 0.90 (BPM-youth) and 0.96 (BPM-teacher) for its total problem score. Corresponding subscales from the long versions and the BPM as well as the total problems scores were closely correlated with coefficients of high effect size (all r > 0.80). The variance of the items of the BPM explained about three-quarters or more of the variance in the corresponding subscales of the long version. The Norwegian BPM has good psychometric properties in terms of 1) being acceptable to good internal consistency and in terms of 2) regression coefficients of high effect size from the BPM items to the problem-scale scores of the long versions as validity indicators. Its use in clinical practice and research can be recommended.

  12. The relationship between admission heart rate and early prognosis in patients with ST-elevation myocardial infarction.

    PubMed

    Salwa, Paweł; Gorczyca-Michta, Iwona; Wożakowska-Kapłon, Beata

    2015-01-01

    Heart rate (HR) is a basic cardiovascular parameter. The relationship between HR and cardiovascular mortality and morbidity has been indicated in clinical trials and epidemiological studies. The evaluation of the relationship between HR upon hospital admission and the in-hospital prognosis in a group of patients with ST-elevation myocardial infarction (STEMI). The medical records of 927 patients were subject to retrospective analysis. The patients were classified on the basis of HR upon hospital admission: < 60 bpm (n = 75), 60-69 bpm (n = 169), 70-79 bpm (n = 245), 80-89 bpm (n = 172), 90-99 bpm (n = 134), and ≥ 100 bpm (n = 132). A group of patients with HR of 60-69 bpm on hospital admission (n = 169) constituted a reference group. Patients with atrioventricular blocks and arrhythmias were excluded from the analysis. Early mortality and co-existing diseases were evaluated in the study population. Patients with HR ≥ 90 bpm demonstrated heart failure symptoms considerably more often than patients with HR of 60-69 bpm (p = 0.0010). In-hospital mortality was significantly higher in patients with a HR of more than 90 bpm and bradycardia. The relationship between HR and cardiovascular mortality is shown with a J-shaped curve. HR is strictly correlated with early cardiovascular mortality in a population of patients with STEMI. The relationship between HR and early mortality is demonstrated by a J-shaped curve.

  13. Quality of life among patients after bilateral prophylactic mastectomy: A systematic review of patient reported outcomes

    PubMed Central

    Razdan, Shantanu N.; Patel, Vishal; Jewell, Sarah; McCarthy, Colleen M.

    2016-01-01

    Purpose Bilateral prophylactic mastectomy (BPM) is effective in reducing the risk of breast cancer in women with a well-defined family history of breast cancer or in women with BRCA 1 or 2 mutations. Evaluating patient-reported outcomes following BPM are thus essential for evaluating success of BPM from patient’s perspective. Our systematic review aimed to: (1) identify studies describing health-related quality of life (HRQOL) in patients following BPM with or without reconstruction; (2) assess the effect of BPM with or without reconstruction on HRQOL; and, (3) identify predictors of HRQOL post BPM. Methods We performed a systematic review of literature using the PRISMA guidelines. PubMed, Embase, PsycINFO, Web of Science, Scopus and Cochrane databases were searched. Results The initial search resulted in 1082 studies; 22 of these studies fulfilled our inclusion criteria. Post BPM, patients are satisfied with the outcomes and report high psychosocial well-being and positive body image. Sexual well-being and somatosensory function are most negatively affected. Vulnerability, psychological distress and preoperative cancer distress are significant negative predictors of quality of life and body image post BPM. Conclusion There is a paucity of high quality data on outcomes of different HRQOL domains post BPM. Future studies should strive to use validated and breast-specific PRO instruments for measuring HRQOL. This will facilitate shared decision-making by enabling surgeons to provide evidence-based answers to women contemplating BPM. PMID:26577764

  14. Time Synchronization Prototype, Server Upgrade Procedure Support and Remote Software Development

    NASA Technical Reports Server (NTRS)

    Sanders, Shania R.

    2014-01-01

    Networks are roadways of communication that connect devices. Like all roadways, there are rules and regulations that govern whatever (information in this case) travels along them. One type of rule that is commonly used is called a protocol. More specifically, a protocol is a standard that specifies how data should be transmitted over a network. The project outlined in this document seeks to implement one protocol in particular, Precision Time Protocol, within the Kennedy Ground Control Subsystem network at Kennedy Space Center. This document also summarizes work completed for server upgrades, remote software developer training and how all three assignments demonstrated the importance of accountability and security.

  15. TAIPAN instrument fibre positioner and Starbug robots: engineering overview

    NASA Astrophysics Data System (ADS)

    Staszak, Nicholas F.; Lawrence, Jon; Brown, David M.; Brown, Rebecca; Zhelem, Ross; Goodwin, Michael; Kuehn, Kyler; Lorente, Nuria P. F.; Nichani, Vijay; Waller, Lew; Case, Scott; Content, Robert; Hopkins, Andrew M.; Klauser, Urs; Pai, Naveen; Mueller, Rolf; Mali, Slavko; Vuong, Minh V.

    2016-07-01

    TAIPAN will conduct a stellar and galaxy survey of the Southern sky. The TAIPAN positioner is being developed as a prototype for the MANIFEST instrument on the GMT. The design for TAIPAN incorporates 150 optical fibres (with an upgrade path to 300) situated within independently controlled robotic positioners known as Starbugs. Starbugs allow precise parallel positioning of individual fibres, thus significantly reducing instrument configuration time and increasing the amount of observing time. Presented is an engineering overview of the UKST upgrade of the completely new Instrument Spider Assembly utilized to support the Starbug Fibre Positioning Robot and current status of the Starbug itself.

  16. Admission Systolic Blood Pressure Predicts the Number of Blood Pressure Medications at Discharge in Patients With Primary Intracerebral Hemorrhage.

    PubMed

    Khawaja, Ayaz M; Shiue, Harn; Boehme, Amelia K; Albright, Karen C; Venkatraman, Anand; Kumar, Gyanendra; Lyerly, Michael J; Hays-Shapshak, Angela; Mirza, Maira; Gropen, Toby I; Harrigan, Mark R

    2018-03-01

    Control of systolic blood pressure (SBP) after primary intracerebral hemorrhage improves outcomes. Factors determining the number of blood pressure medications (BPM) required for goal SBP<160 mm Hg at discharge are unknown. We hypothesized that higher admission-SBPs require a greater number of BPM for goal discharge-SBP<160 mm Hg, and investigated factors influencing this goal. We conducted a retrospective review of 288 patients who presented with primary intracerebral hemorrhage. Admission-SBP was obtained. Primary outcome was the number of BPM at discharge. Comparison was made between patients presenting with and without a history of hypertension, and patients discharged on <3 and ≥3 BPM. Patients with hypertension history had a higher median admission-SBP compared with those without (180 vs. 157 mm Hg, P=0.0001). In total, 133 of 288 (46.2%) patients were discharged on <3 BPM; 155/288 (53.8%) were discharged on ≥3 BPM. Hypertension history (P<0.0001) and admission-SBP (P<0.0001) predicted the number of BPM at discharge. In patients without hypertension history, every 10 mm Hg increase in SBP resulted in an absolute increase of 0.5 BPM at discharge (P=0.0011), whereas in those with hypertension, the absolute increase was 1.3 BPM (P=0.0012). In comparison with patients discharged on <3 BPM, patients discharged on ≥3 BPM were more likely to have a higher median admission-SBP, be younger in age, belong to the African-American race, have a history of diabetes, have higher median admission-National Institutes of Health Stroke Scale and modified Rankin Scale of 4 to 5 at discharge. An understanding of the factors influencing BPM at discharge may help clinicians better optimize blood pressure control both before and after discharge.

  17. Retrospective Evaluation of the Effect of Heart Rate on Survival in Dogs with Atrial Fibrillation.

    PubMed

    Pedro, B; Dukes-McEwan, J; Oyama, M A; Kraus, M S; Gelzer, A R

    2018-01-01

    Atrial fibrillation (AF) usually is associated with a rapid ventricular rate. The optimal heart rate (HR) during AF is unknown. Heart rate affects survival in dogs with chronic AF. Forty-six dogs with AF and 24-hour ambulatory recordings were evaluated. Retrospective study. Holter-derived HR variables were analyzed as follows: mean HR (meanHR, 24-hour average), minimum HR (minHR, 1-minute average), maximum HR (maxHR, 1-minute average). Survival times were recorded from the time of presumed adequate rate control. The primary endpoint was all-cause mortality. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR <125 bpm versus ≥125 bpm. All 46 dogs had structural heart disease; 31 of 46 had congestive heart failure (CHF), 44 of 46 received antiarrhythmic drugs. Of 15 dogs with cardiac death, 14 had CHF. Median time to all-cause death was 524 days (Interquartile range (IQR), 76-1,037 days). MeanHR was 125 bpm (range, 62-203 bpm), minHR was 82 bpm (range, 37-163 bpm), maxHR was 217 bpm (range, 126-307 bpm). These were significantly correlated with all-cause and cardiac-related mortality. For every 10 bpm increase in meanHR, the risk of all-cause mortality increased by 35% (hazard ratio, 1.35; 95% CI, 1.17-1.55; P < 0.001). Median survival time of dogs with meanHR<125 bpm (n = 23) was significantly longer (1,037 days; range, 524-open) than meanHR ≥125 bpm (n = 23; 105 days; range, 67-267 days; P = 0.0012). Mean HR was independently associated with all-cause and cardiovascular mortality (P < 0.003). Holter-derived meanHR affects survival in dogs with AF. Dogs with meanHR <125 bpm lived longer than those with meanHR ≥ 125 bpm. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  18. Difference between BPM reading one bunch and the average of multi-bunch in Booster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xi Yang

    2004-08-18

    Differences caused by BPM reading one bunch and multi-bunch average need to be well understood before the beam parameters, such as the synchrotron tune, betatron tune, and chromaticity, are extracted from those BPM data. It is easy to perform such a study using numerical simulation other than modifying the BPM electronics.

  19. Upgrade of a UV-VIS-NIR imaging spectrometer for the coastal ocean observation: concept, design, fabrication, and test of prototype.

    PubMed

    Yu, Lei

    2017-06-26

    A novel UV-VIS-NIR imaging spectrometer prototype has been presented for the remote sensing of the coastal ocean by air. The concept is proposed for the needs of the observation. An advanced design has been demonstrated based on the Dyson spectrometer in details. The analysis and tests present excellent optical performances in the spectral broadband, easy and low cost fabrication and alignment, low inherent stray light, and high signal to noise ratio. The research provides an easy method for the coastal ocean observation.

  20. CO2 evaporative cooling: The future for tracking detector thermal management

    NASA Astrophysics Data System (ADS)

    Tropea, P.; Daguin, J.; Petagna, P.; Postema, H.; Verlaat, B.; Zwalinski, L.

    2016-07-01

    In the last few years, CO2 evaporative cooling has been one of the favourite technologies chosen for the thermal management of tracking detectors at LHC. ATLAS Insertable B-Layer and CMS Pixel phase 1 upgrade have adopted it and their systems are now operational or under commissioning. The CERN PH-DT team is now merging the lessons learnt on these two systems in order to prepare the design and construction of the cooling systems for the new Upstream Tracker and the Velo upgrade in LHCb, due by 2018. Meanwhile, the preliminary design of the ATLAS and CMS full tracker upgrades is started, and both concepts heavily rely on CO2 evaporative cooling. This paper highlights the performances of the systems now in operation and the challenges to overcome in order to scale them up to the requirements of the future generations of trackers. In particular, it focuses on the conceptual design of a new cooling system suited for the large phase 2 upgrade programmes, which will be validated with the construction of a common prototype in the next years.

  1. Upgrades to the NSTX HHFW antenna

    NASA Astrophysics Data System (ADS)

    Ellis, R.; Brunkhorst, C.; Hosea, J.

    2014-02-01

    The High Harmonic Fast Wave (HHFW) antenna for the National Spherical Torus Experiment (NSTX) at PPPL will be upgraded as part of the NSTX upgrade project. Higher magnetic fields and plasma current result in disruption forces on the current straps that can be up to four times the original design values. The current straps on the HHFW antenna are presently fed by coaxial feedthroughs with rigid center conductors. The additional forces on the current straps require a compliant section in the center conductor in order to minimize the forces on the feedthrough. The design of this compliant section has been an integrated effort involving electrostatic calculations in parallel with mechanical and thermal analyses, in order to arrive at a design that is optimized for mechanical, thermal and electrical considerations. The voltage standoff obtained from this design will be verified when a prototype antenna is evaluated on our RF test stand. This paper describes the design of the compliant section of the center conductor, mechanical, thermal and electrostatic calculations, and plans for full implementation of the upgrade on NSTX.

  2. A bunch to bucket phase detector for the RHIC LLRF upgrade platform

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, K.S.; Harvey, M.; Hayes, T.

    2011-03-28

    As part of the overall development effort for the RHIC LLRF Upgrade Platform [1,2,3], a generic four channel 16 bit Analog-to-Digital Converter (ADC) daughter module was developed to provide high speed, wide dynamic range digitizing and processing of signals from DC to several hundred megahertz. The first operational use of this card was to implement the bunch to bucket phase detector for the RHIC LLRF beam control feedback loops. This paper will describe the design and performance features of this daughter module as a bunch to bucket phase detector, and also provide an overview of its place within the overallmore » LLRF platform architecture as a high performance digitizer and signal processing module suitable to a variety of applications. In modern digital control and signal processing systems, ADCs provide the interface between the analog and digital signal domains. Once digitized, signals are then typically processed using algorithms implemented in field programmable gate array (FPGA) logic, general purpose processors (GPPs), digital signal processors (DSPs) or a combination of these. For the recently developed and commissioned RHIC LLRF Upgrade Platform, we've developed a four channel ADC daughter module based on the Linear Technology LTC2209 16 bit, 160 MSPS ADC and the Xilinx V5FX70T FPGA. The module is designed to be relatively generic in application, and with minimal analog filtering on board, is capable of processing signals from DC to 500 MHz or more. The module's first application was to implement the bunch to bucket phase detector (BTB-PD) for the RHIC LLRF system. The same module also provides DC digitizing of analog processed BPM signals used by the LLRF system for radial feedback.« less

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, X.; Yao, C.

    A prototype dual-blade stripline kicker for the APS multi-bend achromat (MBA) upgrade has been designed and developed. It was optimized with 3D CST Microwave Studio. The high voltage (HV) feedthrough and air-side connector were designed and optimized. Electromagnetic fields along the beam path, the deflecting angle, the high electric fields and their locations were calculated with 15kV differential pulse voltage applied to the kicker blades through the feedthroughs. Beam impedance and the power dissipation on different parts of the kicker and external loads were studied for a 48-bunch fill pattern. Our results show that the prototype kicker with its HVmore » feedthroughs meets the specified requirements. The results of TDR (time-domain reflectometer) test, high voltage pulse test and beam test of the prototype kicker assembly agreed with the simulations.« less

  4. 3D laptop for defense applications

    NASA Astrophysics Data System (ADS)

    Edmondson, Richard; Chenault, David

    2012-06-01

    Polaris Sensor Technologies has developed numerous 3D display systems using a US Army patented approach. These displays have been developed as prototypes for handheld controllers for robotic systems and closed hatch driving, and as part of a TALON robot upgrade for 3D vision, providing depth perception for the operator for improved manipulation and hazard avoidance. In this paper we discuss the prototype rugged 3D laptop computer and its applications to defense missions. The prototype 3D laptop combines full temporal and spatial resolution display with the rugged Amrel laptop computer. The display is viewed through protective passive polarized eyewear, and allows combined 2D and 3D content. Uses include robot tele-operation with live 3D video or synthetically rendered scenery, mission planning and rehearsal, enhanced 3D data interpretation, and simulation.

  5. Using Shoulder Straps Decreases Heart Rate Variability and Salivary Cortisol Concentration in Swedish Ambulance Personnel.

    PubMed

    Karlsson, Kåre J; Niemelä, Patrik H; Jonsson, Anders R; Törnhage, Carl-Johan A

    2016-03-01

    Previous research has shown that paramedics are exposed to risks in the form of injuries to the musculoskeletal system. In addition, there are studies showing that they are also at increased risk of cardiovascular disease, cancer, and psychiatric diseases, which can partly be explained by their constant exposure to stress. The aim of this study is to evaluate whether the use of shoulder straps decreases physical effort in the form of decreased heart rate and cortisol concentration. A stretcher with a dummy was carried by 20 participants for 400 m on two occasions, one with and one without the shoulder straps. Heart rate was monitored continuously and cortisol samples were taken at intervals of 0 minutes, 15 minutes, 30 minutes, 45 minutes, and 60 minutes. Each participant was her or his own control. A significant decrease in heart rate and cortisol concentration was seen when shoulder straps were used. The median values for men (with shoulder straps) at 0 minutes was 78 bpm/21.1 nmol/L (heart rate/cortisol concentration), at 15 minutes was 85 bpm/16.9 nmol/L, and at 60 minutes was 76 bpm/15.7 nmol/L; for men without shoulder straps, these values were 78 bpm/21.9 nmol/L, 93 bpm/21.9 nmol/L, and 73 bpm/20.5 nmol/L. For women, the values were 85 bpm/23.3 nmol/L, 92 bpm/20.8 nmol/L, and 70 bpm/18.4 nmol/L and 84 bpm/32.4 nmol/L, 100 bpm/32.5 nmol/L, and 75 bpm/25.2 nmol/L, respectively. The use of shoulder straps decreases measurable physical stress and should therefore be implemented when heavy equipment or a stretcher needs to be carried. An easy way to ensure that staff use these or similar lifting aids is to provide them with personalized, well-adapted shoulder straps. Another better option would be to routinely sewn these straps into the staff's personal alarm jackets so they are always in place and ready to be used.

  6. Effect of station-specific alerting and ramp-up tones on firefighters' alarm time heart rates.

    PubMed

    MacNeal, James J; Cone, David C; Wistrom, Christopher L

    2016-11-01

    A number of long-term health effects are suffered by emergency responders, some influenced by psychological stress and fatigue. This study explored if stress and fatigue can be reduced by changing the method by which firefighters are alerted to emergency responses. Over several months, the method by which responders at a fire department were alerted was altered. Firefighter heart rates were measured first with standard alerting as a control (phase 1: all stations alerted simultaneously, with high-volume tones). The department then implemented station-specific (phase 2) and gradual volume ramp-up (phase 3) tone alerting, and heart rate increases were compared. The Fatigue Severity Score was used to examine firefighter fatigue, and the department administered a follow-up survey on personnel preferences. Individual heart rate increases (Δbpm) ranged from 2-48 bpm. Median increases were 7 bpm (IQR 4-11 bpm) during phase 1 (72.2% of alarms Δbpm<10), 7 bpm (IQR 5-12 bpm) during phase 2 (60.7% of alarms Δbpm<10), and 5 bpm (IQR 3-8 bpm) during phase 3 (82.7% of alarms Δbpm<10). The difference in medians was lower for phases 1 and 2 than for phase 3 (p = 0.0069), and more alarms in phase 3 resulted in increases of <10 bpm than in phase 2 (p = 0.0089). The Fatigue Severity Scale showed little variability: median scores 7 in phase 1, 8 in phase 2, and 7 in phase 3. Firefighters reported a strong preference for the "ramp-up" tones, and were roughly evenly divided between preferring alerting all stations simultaneously 24/7 (40% rating this 4 or 5 on a five-point Likert scale), station-specific alerting 24/7 (47.5%), or all stations during the day but station-specific at night (40%). Ramp-up tones were perceived as the best method to reduce stress during the day and overnight. Small but significant decreases in the amount of tachycardic response to station alerting are associated with simple alterations in alerting methods. Station-specific and ramp-up tones improve perceived working conditions for emergency responders.

  7. Stimulatory effect on rat thymocytes proliferation and antimicrobial activity of two 6-(propan-2-yl)-4-methyl-morpholine-2,5-diones.

    PubMed

    Pavlovic, Voja; Djordjevic, Aleksandra; Cherneva, Emiliya; Yancheva, Denitsa; Smelcerovic, Andrija

    2012-03-01

    Recently we reported the identification and synthesis of cyclodidepsipeptides, 3,6-di(propan-2-yl)-4-methyl-morpholine-2,5-dione (PPM) and 3-(2-methylpropyl)-6-(propan-2-yl)-4-methyl-morpholine-2,5-dione (BPM), as potential precursors of enniatin B in Fusarium sporotrichioides. No data concerning biological activity of PPM and BPM have hitherto been published. The possible immunomodulatory effect and antimicrobial activity of PPM and BPM were investigated in this study, due to well known biological activities of enniatin B. The cytotoxicity effect of PPM and BPM on rat thymocytes demonstrated that increasing concentrations (0.1, 1, 10 μg/well) of PPM and BPM to cell culture, showed no significant effect on thymocytes toxicity. Simultaneously, incubation with studied cyclodidepsipeptides did not result with decreased mitochondrial membrane potential. Further, thymocytes exposure to increasing concentration of PPM and BPM was not able to induce significant reactive oxygen species (ROS) production in rat thymocytes. PPM and BPM administrations to cell culture in concentrations of 0.1 and 1 μg/well resulted with no significant increase of proliferative activity. However, significantly increased proliferative activity was detected with 10 μg of PPM (p<0.001) and BPM (p<0.05), as compared to their respective controls. The in vitro antimicrobial activity of PPM and BPM was tested against two Gram-positive and three Gram-negative bacteria. The results indicated that MIC values against tested strains ranged between 2.00 and 25.00 mg/ml. PPM showed much better activity against all tested bacteria in comparison with BPM. PPM was equally effective against both Gram-positive and Gram-negative bacteria, at the dose of 2.00 mg/ml. Copyright © 2011 Elsevier Ltd. All rights reserved.

  8. Spinal Cord Injury Impairs Cardiovascular Capacity in Elite Wheelchair Rugby Athletes.

    PubMed

    Gee, Cameron M; Currie, Katharine D; Phillips, Aaron A; Squair, Jordan W; Krassioukov, Andrei V

    2017-12-19

    To examine differences in heart rate (HR) responses during international wheelchair rugby competition between athletes with and without a cervical spinal cord injury (SCI) and across standardized sport classifications. Observational study. The 2015 Parapan American Games wheelchair rugby competition. Forty-three male athletes (31 ± 8 years) with a cervical SCI (n = 32) or tetraequivalent impairment (non-SCI, n = 11). Average and peak HR (HRavg and HRpeak, respectively). To characterize HR responses in accordance with an athletes' International Wheelchair Rugby Federation (IWRF) classification, we separated athletes into 3 groups: group I (IWRF classification 0.5-1.5, n = 15); group II (IWRF classification 2.0, n = 15); and group III (IWRF classification 2.5-3.5, n = 13). Athletes with SCI had lower HRavg (111 ± 14 bpm vs 155 ± 13 bpm) and HRpeak (133 ± 12 bpm vs 178 ± 13 bpm) compared with non-SCI (both P < 0.001). Average HR was higher in group III than in I (136 ± 25 bpm vs 115 ± 20 bpm, P = 0.045); however, SCI athletes showed no difference in HRavg or HRpeak between groups. Within group III, SCI athletes had lower HRavg (115 ± 6 bpm vs 160 ± 8 bpm) and HRpeak (135 ± 11 bpm vs 183 ± 11 bpm) than non-SCI athletes (both P < 0.001). This study is the first to demonstrate attenuated HR responses during competition in SCI compared with non-SCI athletes, likely due to injury to spinal autonomic pathways. Among athletes with SCI, IWRF classification was not related to differences in HR. Specific assessment of autonomic function after SCI may be able to predict HR during competition and consideration of autonomic impairments may improve the classification process.

  9. Effects of smoking on heart rate at rest and during exercise, and on heart rate recovery, in young adults.

    PubMed

    Papathanasiou, George; Georgakopoulos, Dimitris; Papageorgiou, Effie; Zerva, Efthimia; Michalis, Lampros; Kalfakakou, Vasiliki; Evangelou, Angelos

    2013-01-01

    There is an established link between smoking, abnormal heart rate (HR) values, and impaired cardiovascular health in middle-aged or older populations. The purpose of this study was to examine the effects of smoking on resting HR and on HR responses during and after exercise in young adults. A sample of 298 young adults (159 men), aged 20-29 years old, were selected from a large population of health-science students based on health status, body mass index, physical activity, and smoking habit. All subjects underwent a maximal Bruce treadmill test and their HR was recorded during, at peak, and after termination of exercise. Smokers had significantly higher resting HR values than non-smokers. Both female and male smokers showed a significantly slower HR increase during exercise. Female smokers failed to reach their age-predicted maximum HR by 6.0 bpm and males by 3.6 bpm. The actual maximum HR achieved (HRmax) was significantly lower for both female smokers (191.0 bpm vs.198.0 bpm) and male smokers (193.2 bpm vs.199.3 bpm), compared to non-smokers. Heart rate reserve was also significantly lower in female (114.6 bpm vs. 128.1 bpm) and male smokers (120.4 bpm vs. 133.0 bpm). During recovery, the HR decline was significantly attenuated, but only in female smokers. Females had a higher resting HR and showed a higher HR response during sub-maximal exercise compared to males. Smoking was found to affect young smokers' HR, increasing HR at rest, slowing HR increase during exercise and impairing their ability to reach the age-predicted HRmax. In addition, smoking was associated with an attenuated HR decline during recovery, but only in females.

  10. Evaluation of in-hospital electrocardiography versus 24-hour Holter for rate control in dogs with atrial fibrillation.

    PubMed

    Gelzer, A R; Kraus, M S; Rishniw, M

    2015-07-01

    To determine if the in-clinic ECG-derived heart rate could predict the at-home Holter-derived 24-hour average heart rate (Holter24h ), and whether it is useful to identify slow versus fast atrial fibrillation in dogs. 82 pairs of 1-minute ECGs and 24-hour Holter recordings were acquired in 34 dogs with atrial fibrillation. The initial 24-hour Holter was used to test if the ECG heart rate can identify dogs with "slow" versus "fast" atrial fibrillation based on a Holter24h threshold value of 140 bpm. ECG heart rate overestimated Holter24h by 26 bpm (95% CI: 3 bpm, 48 bpm; P < 0 · 015) with a 95% limit of agreement of -21 to 83 bpm. The in-clinic ECG-derived heart rate Ä155 bpm had a sensitivity of 73% and a specificity of 100% for identifying a Holter24h HR Ä140 bpm; an in-clinic ECG-derived HR <160 bpm had a sensitivity and specificity of 91% each. In-clinic ECG assessment of heart rate in dogs with atrial fibrillation does not reliably predict the heart rate in their home environment. However, an in-clinic heart rate greater than 155 bpm is useful in identifying "fast" atrial fibrillation, allowing clinicians to stratify which case may benefit from antiarrhythmic therapy. © 2015 British Small Animal Veterinary Association.

  11. Experiment Needs and Facilities Study Appendix A Transient Reactor Test Facility (TREAT) Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The TREAT Upgrade effort is designed to provide significant new capabilities to satisfy experiment requirements associated with key LMFBR Safety Issues. The upgrade consists of reactor-core modifications to supply the physics performance needed for the new experiments, an Advanced TREAT loop with size and thermal-hydraulics capabilities needed for the experiments, associated interface equipment for loop operations and handling, and facility modifications necessary to accommodate operations with the Loop. The costs and schedules of the tasks to be accomplished under the TREAT Upgrade project are summarized. Cost, including contingency, is about 10 million dollars (1976 dollars). A schedule for execution ofmore » 36 months has been established to provide the new capabilities in order to provide timely support of the LMFBR national effort. A key requirement for the facility modifications is that the reactor availability will not be interrupted for more than 12 weeks during the upgrade. The Advanced TREAT loop is the prototype for the STF small-bundle package loop. Modified TREAT fuel elements contain segments of graphite-matrix fuel with graded uranium loadings similar to those of STF. In addition, the TREAT upgrade provides for use of STF-like stainless steel-UO{sub 2} TREAT fuel for tests of fully enriched fuel bundles. This report will introduce the Upgrade study by presenting a brief description of the scope, performance capability, safety considerations, cost schedule, and development requirements. This work is followed by a "Design Description". Because greatly upgraded loop performance is central to the upgrade, a description is given of Advanced TREAT loop requirements prior to description of the loop concept. Performance requirements of the upgraded reactor system are given. An extensive discussion of the reactor physics calculations performed for the Upgrade concept study is provided. Adequate physics performance is essential for performance of experiments with the Advanced TREAT loop, and the stress placed on these calculations reflects this. Additional material on performance and safety is provided. Backup calculations on calculations of plutonium-release limits are described. Cost and schedule information for the Upgrade are presented.« less

  12. Development of a miniature motor-driven pulsatile LVAD driven by a fuzzy controller.

    PubMed

    Okamoto, Eiji; Makino, Tsutomu; Tanaka, Shuji; Yasuda, Takahiko; Akasaka, Yuta; Tani, Makiko; Inoue, Yusuke; Mitoh, Ayumu; Mitamura, Yoshinori

    2007-01-01

    We have been developing a small, lightweight motor-driven pulsatile left ventricular assist device (LVAD) with a ball screw. The motor-driven LVAD consists of a brushless DC motor and a ball screw. The attractive magnetic force between Nd-Fe-B magnets (with a diameter of 5 mm and a thickness of 1.5 mm) mounted in holes in a silicone rubber sheet (thickness 2 mm) and an iron plate adhered onto the a diaphragm of the blood pump can provide optimum active blood filling during the pump filling phase. The LVAD has a stroke volume of 55 ml and an overall volume of 285 ml; it weighs 360 g. The controller mainly consists of a fuzzy logic position and velocity controller to apply doctors' and engineers' knowledge to control the LVAD. Each unit of the controller consists of a functionally independent program module for easy improvement of the controller's performance. The LVAD was evaluated in in vitro experiments using a mock circulation. A maximum pump outflow of 5.1 l/min was obtained at a drive rate of 95 bpm against an afterload of 95 mmHg, and active filling using the attractive magnetic force provided a pump output of 3.6 l/min at a drive rate of 75 bpm under a preload of 0 mmHg. The operating efficiency of the LVAD was measured at between 8% and 10.5%. While the LVAD can provide adequate pump outflow for cardiac assistance, further upgrading of the software and improvement of the blood pump are required to improve pump performance and efficiency.

  13. Synthesis, structure, and magnetic properties of regular alternating μ-bpm/di-μ-X copper(II) chains (bpm = 2,2'-bipyrimidine; X = OH, F).

    PubMed

    Marino, Nadia; Armentano, Donatella; De Munno, Giovanni; Cano, Joan; Lloret, Francesc; Julve, Miguel

    2012-04-02

    The preparation and X-ray crystal structure of four 2,2'-bipyrimidine (bpm)-containing copper(II) complexes of formula {[Cu(2)(μ-bpm)(H(2)O)(4)(μ-OH)(2)][Mn(H(2)O)(6)](SO(4))(2)}(n) (1), {[Cu(2)(μ-bpm)(H(2)O)(4)(μ-OH)(2)]SiF(6)}(n) (2), {Cu(2)(μ-bpm)(H(2)O)(2)(μ-F)(2)F(2)}(n) (3), and [Cu(bpm)(H(2)O)(2)F(NO(3))][Cu(bpm)(H(2)O)(3)F]NO(3)·2H(2)O (4) are reported. The structures of 1-3 consist of chains of copper(II) ions with regular alternation of bis-bidentate bpm and di-μ-hydroxo (1 and 2) or di-μ-fluoro (3) groups, the electroneutrality being achieved by either hexaaqua manganese(II) cations plus uncoordinated sulfate anions (1), uncoordinated hexafluorosilicate anions (2), or terminally bound fluoride ligands (3). Each copper(II) ion in 1-4 is six-coordinated in elongated octahedral surroundings. 1 and 2 show identical, linear chain motifs with two bpm-nitrogen atoms and two hydroxo groups building the equatorial plane at each copper(II) ion and the axial position being filled by water molecules. In the case of 3, the axial sites at the copper atom are occupied by a bpm-nitrogen atom and a bis-monodentate fluoride anion, producing a "step-like" chain motif. The values of the angle at the hydroxo and fluoro bridges are 94.11(6) (1), 94.75(4) (2), and 101.43(4)° (3). In each case, the copper-copper separation through the bis-bidentate bpm [5.428(1) (1), 5.449(1) (2), and 5.9250(4) Å (3)] is considerably longer than that through the di-μ-hydroxo [2.8320(4) (1) and 2.824(1) Å (2)] or di-μ-fluoro [3.3027(4) Å (3)] bridges. Compound 4 is a mononuclear species whose structure is made up of neutral [Cu(bpm)(H(2)O)(2)F(NO(3))] units, [Cu(bpm)(H(2)O)(3)F](+) cations, uncoordinated nitrate anions, and crystallization water molecules, giving rise to a pseudo-helical, one-dimensional (1D) supramolecular motif. The magnetic properties of 1-3 have been investigated in the temperature range 1.9-300 K. Relatively large, alternating antiferro- [J = -149 (1) and -141 cm(-1) (2) across bis-bidentate bpm] and ferromagnetic [αJ = +194 (1) and +176 cm(-1) (2) through the dihydroxo bridges] interactions occur in 1 and 2 [the Hamiltonian being defined as H = -J∑(i=1)(n/2) (S(2i)·S(2i-1) - αS(2i)·S(2i+1))]. These values compare well with those previously reported for parent examples. Two weak intrachain antiferromagnetic interactions [J = -0.30 and αJ = -8.1 cm(-1) across bpm and the di-μ-fluoro bridges, respectively] whose values were substantiated by density functional theory (DFT)-type calculations occur in 3.

  14. Postural tachycardia syndrome and inappropriate sinus tachycardia: role of autonomic modulation and sinus node automaticity.

    PubMed

    Nwazue, Victor C; Paranjape, Sachin Y; Black, Bonnie K; Biaggioni, Italo; Diedrich, André; Dupont, William D; Robertson, David; Raj, Satish R

    2014-04-10

    Inappropriate sinus tachycardia (IST) and postural tachycardia syndrome (POTS) are 2 disorders characterized by sinus tachycardia. It is debated whether the pathophysiology of IST and POTS results from abnormal autonomic regulation or abnormal sinus node function. We hypothesized that intrinsic heart rate (IHR) after autonomic blockade would be increased in patients with IST but not POTS. We enrolled 48 POTS patients, 8 IST patients, and 17 healthy control (HC) subjects. Intravenous propranolol and atropine were given to block the sympathetic and parasympathetic limbs of the autonomic nervous system in order to determine the IHR. Patients with IST have a higher sympathetic contribution to heart rate when compared with POTS patients (31±13 bpm versus 12±7 bpm, P<0.001) and HC (8±4 bpm; P<0.001) and a trend to less parasympathetic contribution than POTS and HC (IST: 31±11 bpm versus POTS: 46±11 bpm versus HC: 48±11 bpm, ANOVA P=0.108). IHR was not significantly different between IST and either POTS or HC (IST: 111±11 bpm versus POTS: 108±11 bpm versus HC: 106±12 bpm, ANOVA P=0.237). IST patients have more sympathetic tone when compared with either POTS or HC, but IST patients do not have abnormal sinus node automaticity. These data suggest that the treatment of IST and POTS should focus on sympatholysis, reserving sinus node modification for patients with continued debilitating symptoms after beta-blockade and possibly ivabradine. http://clinicaltrials.gov/. Unique identifier: NCT00262470.

  15. International Infantry and Joint Services Small Arms Systems Section Symposium, Exhibition and Firing Demonstration. Held in Atlantic City, NJ on 13-16 May 2002. Volume 3

    DTIC Science & Technology

    2002-05-13

    Mount • Install Large Capacity Ammo Container On Mount • Add Actuators And Resolvers For Laying OCSW Independent Of Main Gun t ti f t ti...FY07 FY08 FY09 FY10 FY11 FY12 4 5 6 SI Prod Block II (2K FLIR,Dual Feed, CPU Upgrade, AP Enhancements, MEMS) IOT &E LFT&E LUT...PQT Fielding (T) SDD C&TD Production LRIP SDD Prototypes Prototype Build BDENET MS B FRP MS C LRIP FCS S D D P ro to ty p es IOTE SD LRIP OCSW

  16. Single Pass Stripline Beam Position Monitor Design, Fabrication and Commissioning

    NASA Astrophysics Data System (ADS)

    Tan, Y.-R. E.; Wang, D.; Van Garderen, E.; McKinlay, J.

    2012-10-01

    To monitor the position of the electron beam during transport from the Booster Synchrotron to the Storage Ring at the Australian Synchrotron, a stripline Beam Position Monitor (BPM) has been designed, fabricated and installed in-house. The design was based on an existing stripline in the Booster and modified for the transfer line with a particular emphasis on ensuring the line impedance is properly matched to the detector system. The initial bench tests of a prototype stripline showed that the fabrication of the four individual striplines in the BPM was made precisely, each with a measured standing wave ratio (SWR) of 1.8 at 500 MHz. Further optimization for impedance matching will be done for new stripline BPMs. The linearity and gain factor was measured with the detector system. The detector system that digitizes the signals is an Instrumentation Technologies Brilliance Single Pass [1]. The results show an error of 1 mm at an offset (from the electrical centre) of 10 mm when a linear gain factor is assumed and an RMS noise of ~150 um that decreases to < 10 um with increasing signal intensity. The results were under our requirements for the transport line. The commissioning results of the stripline will also be presented showing a strong signal for an electron beam with an estimated integrated charge of ~50 nC with a position stability of 28 um (horizontal) and 75 um (vertical).

  17. BPM System for Electron Cooling in the Fermilab Recycler Ring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joireman, Paul W.; Cai, Jerry; Chase, Brian E.

    2004-11-10

    We report a VXI based system used to acquire and process BPM data for the electron cooling system in the Fermilab Recycler ring. The BPM system supports acquisition of data from 19 BPM locations in five different sections of the electron cooling apparatus. Beam positions for both electrons and anti-protons can be detected simultaneously with a resolution of {+-}50 {mu}m. We calibrate the system independently for each beam type at each BPM location. We describe the system components, signal processing and modes of operation used in support of the electron-cooling project and present experimental results of system performance for themore » developmental electron cooling installation at Fermilab.« less

  18. Performance evaluation of BPM system in SSRF using PCA method

    NASA Astrophysics Data System (ADS)

    Chen, Zhi-Chu; Leng, Yong-Bin; Yan, Ying-Bing; Yuan, Ren-Xian; Lai, Long-Wei

    2014-07-01

    The beam position monitor (BPM) system is of most importance in a light source. The capability of the BPM depends on the resolution of the system. The traditional standard deviation on the raw data method merely gives the upper limit of the resolution. Principal component analysis (PCA) had been introduced in the accelerator physics and it could be used to get rid of the actual signals. Beam related information was extracted before the evaluation of the BPM performance. A series of studies had been made in the Shanghai Synchrotron Radiation Facility (SSRF) and PCA was proved to be an effective and robust method in the performance evaluations of our BPM system.

  19. Screening for coronary artery disease in respiratory patients: comparison of single- and dual-source CT in patients with a heart rate above 70 bpm.

    PubMed

    Pansini, Vittorio; Remy-Jardin, Martine; Tacelli, Nunzia; Faivre, Jean-Baptiste; Flohr, Thomas; Deken, Valérie; Duhamel, Alain; Remy, Jacques

    2008-10-01

    To evaluate the assessibility of coronary arteries in respiratory patients with high heart rates. This study was based on the comparative analysis of two paired populations of 54 patients with a heart rate >70 bpm evaluated with dual-source (group 1) and single-source (group 2) CT. The mean heart rate was 89.1 bpm in group 1 and 86.7 bpm in group 2 (P=0.26). The mean number of assessable segments per patient was significantly higher in group 1 compared to group 2 (P

  20. A multi-channel opto-electronic sensor to accurately monitor heart rate against motion artefact during exercise.

    PubMed

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-10-12

    This study presents the use of a multi-channel opto-electronic sensor (OEPS) to effectively monitor critical physiological parameters whilst preventing motion artefact as increasingly demanded by personal healthcare. The aim of this work was to study how to capture the heart rate (HR) efficiently through a well-constructed OEPS and a 3-axis accelerometer with wireless communication. A protocol was designed to incorporate sitting, standing, walking, running and cycling. The datasets collected from these activities were processed to elaborate sport physiological effects. t-test, Bland-Altman Agreement (BAA), and correlation to evaluate the performance of the OEPS were used against Polar and Mio-Alpha HR monitors. No differences in the HR were found between OEPS, and either Polar or Mio-Alpha (both p > 0.05); a strong correlation was found between Polar and OEPS (r: 0.96, p < 0.001); the bias of BAA 0.85 bpm, the standard deviation (SD) 9.20 bpm, and the limits of agreement (LOA) from -17.18 bpm to +18.88 bpm. For the Mio-Alpha and OEPS, a strong correlation was found (r: 0.96, p < 0.001); the bias of BAA 1.63 bpm, SD 8.62 bpm, LOA from -15.27 bpm to +18.58 bpm. These results demonstrate the OEPS to be capable of carrying out real time and remote monitoring of heart rate.

  1. Influence of the motion correction algorithm on the quality and interpretability of images of single-source 64-detector coronary CT angiography among patients grouped by heart rate.

    PubMed

    Machida, Haruhiko; Lin, Xiao-Zhu; Fukui, Rika; Shen, Yun; Suzuki, Shigeru; Tanaka, Isao; Ishikawa, Takuya; Tate, Etsuko; Ueno, Eiko

    2015-02-01

    We retrospectively investigated the effect of the motion correction algorithm (MCA) on image quality and interpretability by heart rate (HR) in coronary CT angiography (CCTA). For 105 patients (6 HR groups) undergoing CCTA, 2 readers independently graded the image quality of the 4 major coronary arteries reconstructed with and without MCA at diastole with HR ≤64 bpm and at systole and diastole ≥65 bpm using a 5-point scale. For each HR group and cardiac phase, we compared per-vessel and per-segment image quality using Wilcoxon signed rank test and percentages of interpretable image quality (scores 3-5) among without MCA at diastole with HR ≤64 bpm, as a reference, with MCA at diastole ≤69 bpm and at systole 70-79 bpm using the chi-square test. The motion correction algorithm reconstruction provided similar or better image quality and interpretability in all groups, with 96-100 % per-vessel (P = 0.008 for the right coronary artery; otherwise, P > 0.05) and 99 % per-segment interpretable image quality (P = 0.0002) at diastole with HR ≤69 bpm and at systole 70-79 bpm compared to the reference (88-100 and 97 %, respectively). MCA reconstruction preserved image quality and interpretability of CCTA with HR ≤79 bpm.

  2. Reduction of resting heart rate with antianginal drugs: review and meta-analysis.

    PubMed

    Cucherat, Michel; Borer, Jeffrey S

    2012-07-01

    The benefit of heart rate (HR) reduction in patients with stable coronary artery disease is well demonstrated for symptom prevention and relief, and benefits on outcomes are being actively investigated. We aimed to quantify the reduction in resting HR induced by 5 antianginal drugs frequently used for symptom prevention (diltiazem, verapamil, atenolol, metoprolol, and ivabradine) in stable angina pectoris. We identified studies published between 1966 and 2007 in PubMed, Embase, and the Cochrane database and reviewed the bibliographies to locate additional studies. Eligible studies were double-blind, randomized, placebo-controlled trials in patients with stable angina. Trials were combined using weighted mean difference and fixed-effect model meta-analysis. The main outcome measure was resting HR at the study end. For diltiazem, resting HR reduction versus placebo ranged from -0.08 beats per minute (bpm) [95% confidence interval (CI) -1.5 to +1.4] for 120 mg/d to -8.0 bpm (95% CI, -11.1 to -5.0) with 360 mg/d. For sustained-release diltiazem, there was a reduction in resting HR of -4.5 bpm (95% CI, -6.4 to -2.5), with no dose-response relationship (heterogeneity P = 0.62). Resting HR reductions for the other agents were -3.2 bpm (95% CI, -5.1 to -1.3) for verapamil (with no dose-response relationship, heterogeneity P = 0.87); -19.0 bpm (95% CI, -20.4 to -17.6) for atenolol; -13.2 bpm (95% CI, -14.7 to -11.7) for metoprolol (with greater reductions for 150 mg/d and long-acting 190 mg/d); and between -9.3 bpm (95% CI, -13.8 to -4.8) and -19.6 bpm (95% CI, -23.8 to -15.4) for ivabradine. Ivabradine, atenolol, and metoprolol give similar reductions in resting HR (-10 to -20 bpm), whereas verapamil and diltiazem produce only marginal reductions (<10 bpm).

  3. [Heart rate control in chronic heart failure patients received cardiovascular implantable electronic device therapy: effects of optimized medication].

    PubMed

    Gao, Y; Liang, Y C; Yu, H B; Yan, X L; Xu, B G; Liu, R; Wang, N; Xu, G Q; Wang, Z L

    2018-03-24

    Objective: To investigate the heart rate control situation of chronic heart failure (CHF) patients who received cardiovascular implantable electronic device (CIED) therapy, and to assess the heart rate control efficacy by optimized medication adjustment. Methods: We performed a perspective study in heart failure with reduced left ventricular ejection fraction (HFrEF) patients who received CIED according to guideline recommendations, patients were enrolled from January 2012 to January 2017. Resting heart rate (RHR) recorded by electrocardiogram after 10 minutes' rest and medication usage within 1 month were recorded at baseline. RHR less than 70 beats per minute (bpm) was regarded as well controlled. β-receptor blockers and (or) ivabradine would be added in patients whose RHR were over 70 bpm. RHR after optimized medication adjustment was recorded during follow-up period. Results: One hundred and fifty patients were included in this study with average RHR (80.6±11.9) bpm. RHR was<70 bpm in 27.3% (41/150) patients at baseline and β-receptor blockers was underused in 80.7% patients (88/109) whose RHR was>70 bpm. The overall RHR decreased to (73.1±10.4) bpm and percent of patients with RHR<70 bpm increased to 70.0% (105/150) after up-titration of β-receptor blockers compared to baseline (χ 2 =52.958, P< 0.001). Ivabradine was added in the rest 45 patients and RHR was<70 bpm in 43 out of 45 patients after ivabradine use. The overall RHR decreased to (67.1±2.7) bpm and percent of RHR<70 bpm significantly increased to 98.7% (148/150) (χ 2 =44.504, P< 0.001 vs. up-titration of β-receptor blockers only). Conclusion: RHR in CHF patients who received CIED therapy is not ideally controlled in this patient cohort, individual up-titration ofβ-receptor blockers and ivabradine use may help to optimize RHR in these patients.

  4. Association between resting heart rate, metabolic syndrome and cardiorespiratory fitness in Korean male adults.

    PubMed

    Kang, Seol-Jung; Ha, Gi-Chul; Ko, Kwang-Jun

    2017-06-01

    The present study aimed to investigate the association between metabolic syndrome and cardiorespiratory fitness according to resting heart rate of Korean male adults. A total of 11,876 male adults aged 20-65 years who underwent health examinations from 2010 to 2015 at a National Fitness Centre in South Korea were included. Subjects' resting heart rate, cardiorespiratory fitness (VO 2 max), and metabolic syndrome parameters were collected. The subjects were divided into 5 categories (<60 bpm, 60-69 bpm, 70-79 bpm, 80-89 bpm, and ≥90 bpm) of resting heart rate for further analysis. We found that elevated resting heart rate was positively associated with body mass index, systolic blood pressure, diastolic blood pressure, triglycerides, and fasting blood glucose levels ( p  < 0.001, respectively); in contrast, elevated resting heart rate was inversely associated with VO 2 max ( p  < 0.001). When resting heart rate of subjects was categorized into quintiles and analysed, the results showed that the relative risk of metabolic syndrome was 1.53-fold higher (95% CI, 1.34 to 1.82) in the range of 60-69 beats per minute (bpm), 2.08-fold higher (95% CI, 1.77 to 2.45) in the range of 70-79 bpm, 2.28-fold higher (95% CI, 1.73 to 3.00) in the range of 80-89 bpm, and 2.61-fold higher (95% CI, 1.62 to 4.20) in the range of ≥90 bpm, compared to those <60 bpm; this indicated that as resting heart rate increased, the relative risk of metabolic syndrome also increased. Resting heart rate of male adults was found to be associated with cardiorespiratory fitness; the risk factors for metabolic syndrome and relative risk of metabolic syndrome increased as resting heart rate increased.

  5. [Time-dependent heart rate variability in the head-up tilt test in children with postural orthostatic tachycardia syndrome].

    PubMed

    Ran, Jing; Wang, Cheng; Zou, Run-Mei; Wu, Li-Jia; Lin, Ping; Li, Fang; Xu, Yi

    2015-10-01

    To study the time-dependent heart rate (HR) variability in the head-up tilt test (HUTT) in children with postural orthostatic tachycardia syndrome (POTS) and to explore the HR diagnostic criteria for POTS in children. A retrospective analysis was performed on the clinical data of 105 children diagnosed with POTS with HR≥120 beats per minute (bpm) within the first 10 minutes of HUTT between January 2007 and December 2014. Their HR variability within the first 10 minutes of HUTT was analyzed. The HR of children with POTS increased gradually from the supine position to a 60° head-up tilt position, and the increase in HR was 24±12 bpm at the beginning of HUTT, 30±14 bpm at 3 minutes of HUTT, 32±13 bpm at 5 minutes of HUTT, and 38±12 bpm at 10 minutes of HUTT. The average maximal HR increase within the first 10 minutes of HUTT was 43±10 bpm. In children with POTS, the HR variability gradually increases with time, and therefore, it is suggested that HR increase ≥40 bpm is more suitable for diagnosis of POTS in children.

  6. Modulation of Ca(v)3.1 T-type Ca2+ channels by the ran binding protein RanBPM.

    PubMed

    Kim, Taehyun; Kim, Sunoh; Yun, Hyung-Mun; Chung, Kwang Chul; Han, Ye Sun; Shin, Hee-Sup; Rhim, Hyewhon

    2009-01-02

    In order to study the currently unknown cellular signaling pathways of Ca(v)3.1 T-type Ca(2+) channels (Ca(v)3.1 channels), we performed a yeast two-hybrid screening using intracellular domains of Ca(v)3.1 alpha1 subunit as bait. After screening the human brain cDNA library, several proteins, including RanBPM, were identified as interacting with Ca(v)3.1 channels. RanBPM was found to bind to the cytoplasmic intracellular loop between transmembrane domains I and II of Ca(v)3.1 channels. Using whole-cell patch-clamp techniques, we found that Ca(v)3.1 currents were increased by the expression of RanBPM in HEK293/Ca(v)3.1 cells. We next examined whether RanBPM affected the biophysical properties and plasma membrane expression of Ca(v)3.1 channels. Furthermore, we showed that the PKC activator inhibited Ca(v)3.1 currents, an effect that was abolished by the expression of RanBPM. These results suggest that RanBPM could be a key regulator of Ca(v)3.1 channel-mediated signaling pathways.

  7. Automated grading, upgrading, and cuttings prediction of surfaced dry hardwood lumber

    Treesearch

    Sang-Mook Lee; Phil Araman; A.Lynn Abbott; Matthew F. Winn

    2010-01-01

    This paper concerns the scanning, sawing, and grading of kiln-dried hardwood lumber. A prototype system is described that uses laser sources and a video camera to scan boards. The system automatically detects defects and wane, searches for optimal sawing solutions, and then estimates the grades of the boards that would result. The goal is to derive maximum commercial...

  8. Law Enforcement Head-Borne Personal Protective Equipment Hearing Attenuation

    DTIC Science & Technology

    2009-04-01

    thus allowing for a binaural recording to be captured. The BOB was placed on a manual turntable to allow the BOB to be rotated along the azimuth...listed in the Appendix. Each movement should be conducted 8 times at a rate of 50 beats per minute (BPM) and 80 BPM; this will be defined as slow...APPENDIX FABRIC NOISE TEST MOVEMENTS AND SPEEDS The below movements must be performed at a rate of 50 beats per minute (BPM) and 80 BPM: Movement

  9. Development of the PEFP's beam line BPM

    NASA Astrophysics Data System (ADS)

    Ryu, Jin-Yeong; Kwon, Hyeok-Jung; Jang, Ji-Ho; Kim, Han-Sung; Seol, Kyung-Tae; Cho, Yong-Sub

    2013-01-01

    The Proton Engineering Frontier Project (PEFP) has 20-MeV and 100-MeV beam lines to supply proton beams to users. A stripline-type Beam Position Monitor (BPM) was designed and fabricated in order to measure the beam's position in the beam line. The RF properties of the BPM were measured and compared with the simulation. After the sensitivity of the BPM at a test stand had been obtained, we performed a beam test in a test beam line of the PEFP 20-MeV proton linac.

  10. The new Inner Tracking System of the ALICE experiment

    NASA Astrophysics Data System (ADS)

    Martinengo, P.; Alice Collaboration

    2017-11-01

    The ALICE experiment will undergo a major upgrade during the next LHC Long Shutdown scheduled in 2019-20 that will enable a detailed study of the properties of the QGP, exploiting the increased Pb-Pb luminosity expected during Run 3 and Run 4. The replacement of the existing Inner Tracking System with a completely new ultra-light, high-resolution detector is one of the cornerstones within this upgrade program. The main motivation of the ITS upgrade is to provide ALICE with an improved tracking capability and impact parameter resolution at very low transverse momentum, as well as to enable a substantial increase of the readout rate. The new ITS will consist of seven layers of innovative Monolithic Active Pixel Sensors with the innermost layer sitting at only 23 mm from the interaction point. This talk will focus on the design and the physics performance of the new ITS, as well as the technology choices adopted. The status of the project and the results from the prototypes characterization will also be presented.

  11. Data acquisition and processing in the ATLAS tile calorimeter phase-II upgrade demonstrator

    NASA Astrophysics Data System (ADS)

    Valero, A.; Tile Calorimeter System, ATLAS

    2017-10-01

    The LHC has planned a series of upgrades culminating in the High Luminosity LHC which will have an average luminosity 5-7 times larger than the nominal Run 2 value. The ATLAS Tile Calorimeter will undergo an upgrade to accommodate the HL-LHC parameters. The TileCal readout electronics will be redesigned, introducing a new readout strategy. A Demonstrator program has been developed to evaluate the new proposed readout architecture and prototypes of all the components. In the Demonstrator, the detector data received in the Tile PreProcessors (PPr) are stored in pipeline buffers and upon the reception of an external trigger signal the data events are processed, packed and readout in parallel through the legacy ROD system, the new Front-End Link eXchange system and an ethernet connection for monitoring purposes. This contribution describes in detail the data processing and the hardware, firmware and software components of the TileCal Demonstrator readout system.

  12. Comparing in vitro and in vivo virulence phenotypes of Burkholderia pseudomallei type G strains.

    PubMed

    Lewis, Eric R G; Kilgore, Paul B; Mott, Tiffany M; Pradenas, Gonzalo A; Torres, Alfredo G

    2017-01-01

    Burkholderia pseudomallei (Bpm) is a saprophytic rod-shaped gram-negative bacterium and the causative agent of melioidosis. This disease has previously been described as endemic in areas such as northern Australia and Southeast Asia, but, more recently, a better understanding of the epidemiology of melioidosis indicated that the disease is distributed worldwide, including regions of the Americas and Africa. A 16S-23S rDNA internal transcribed spacer (ITS) typing system has been developed for Bpm and has revealed that ITS types C, E, and hybrid CE are mainly associated with Australia and Southeast Asia while type G strains are more associated with cases of melioidosis in the Western Hemisphere. The purpose of the current study was to determine the in vitro and in vivo virulence profiles of the understudied Bpm type G strains Ca2009, Ca2013a, Mx2013, and 724644 and compared such phenotypes to the commonly studied Bpm type C strain K96243. We evaluated virulence by measuring invasion/uptake and survival of these Bpm strains in murine respiratory epithelial LA-4 cells and alveolar macrophage MH-S cells using different multiplicity of infections (MOIs of 1 and 10). We also calculated the lethal dose 50 values (LD50) in BALB/c mice that were inoculated intranasally with either Ca2009, Ca2013a, or Mx2013. Overall, the virulence and lethality phenotypes of Bpm type G strains were similar to the Bpm type C strain K96243. Additional comparative analyses between the Bpm ITS types may lead to a better understanding of the contribution of the ITS type to the epidemiology and ecology of Bpm strains.

  13. Performance of turbo high-pitch dual-source CT for coronary CT angiography: first ex vivo and patient experience.

    PubMed

    Morsbach, Fabian; Gordic, Sonja; Desbiolles, Lotus; Husarik, Daniela; Frauenfelder, Thomas; Schmidt, Bernhard; Allmendinger, Thomas; Wildermuth, Simon; Alkadhi, Hatem; Leschka, Sebastian

    2014-08-01

    To evaluate image quality, maximal heart rate allowing for diagnostic imaging, and radiation dose of turbo high-pitch dual-source coronary computed tomographic angiography (CCTA). First, a cardiac motion phantom simulating heart rates (HRs) from 60-90 bpm in 5-bpm steps was examined on a third-generation dual-source 192-slice CT (prospective ECG-triggering, pitch 3.2; rotation time, 250 ms). Subjective image quality regarding the presence of motion artefacts was interpreted by two readers on a four-point scale (1, excellent; 4, non-diagnostic). Objective image quality was assessed by calculating distortion vectors. Thereafter, 20 consecutive patients (median, 50 years) undergoing clinically indicated CCTA were included. In the phantom study, image quality was rated diagnostic up to the HR75 bpm, with object distortion being 1 mm or less. Distortion increased above 1 mm at HR of 80-90 bpm. Patients had a mean HR of 66 bpm (47-78 bpm). Coronary segments were of diagnostic image quality for all patients with HR up to 73 bpm. Average effective radiation dose in patients was 0.6 ± 0.3 mSv. Our combined phantom and patient study indicates that CCTA with turbo high-pitch third-generation dual-source 192-slice CT can be performed at HR up to 75 bpm while maintaining diagnostic image quality, being associated with an average radiation dose of 0.6 mSv. • CCTA is feasible with the turbo high-pitch mode. • Turbo high-pitch CCTA provides diagnostic image quality up to 73 bpm. • The radiation dose of high-pitch CCTA is 0.6 mSv on average.

  14. Comparing in vitro and in vivo virulence phenotypes of Burkholderia pseudomallei type G strains

    PubMed Central

    Mott, Tiffany M.; Pradenas, Gonzalo A.

    2017-01-01

    Burkholderia pseudomallei (Bpm) is a saprophytic rod-shaped gram-negative bacterium and the causative agent of melioidosis. This disease has previously been described as endemic in areas such as northern Australia and Southeast Asia, but, more recently, a better understanding of the epidemiology of melioidosis indicated that the disease is distributed worldwide, including regions of the Americas and Africa. A 16S-23S rDNA internal transcribed spacer (ITS) typing system has been developed for Bpm and has revealed that ITS types C, E, and hybrid CE are mainly associated with Australia and Southeast Asia while type G strains are more associated with cases of melioidosis in the Western Hemisphere. The purpose of the current study was to determine the in vitro and in vivo virulence profiles of the understudied Bpm type G strains Ca2009, Ca2013a, Mx2013, and 724644 and compared such phenotypes to the commonly studied Bpm type C strain K96243. We evaluated virulence by measuring invasion/uptake and survival of these Bpm strains in murine respiratory epithelial LA-4 cells and alveolar macrophage MH-S cells using different multiplicity of infections (MOIs of 1 and 10). We also calculated the lethal dose 50 values (LD50) in BALB/c mice that were inoculated intranasally with either Ca2009, Ca2013a, or Mx2013. Overall, the virulence and lethality phenotypes of Bpm type G strains were similar to the Bpm type C strain K96243. Additional comparative analyses between the Bpm ITS types may lead to a better understanding of the contribution of the ITS type to the epidemiology and ecology of Bpm strains. PMID:28414823

  15. Effects of renal sympathetic denervation on heart rate and atrioventricular conduction in patients with resistant hypertension.

    PubMed

    Ukena, Christian; Mahfoud, Felix; Spies, Aline; Kindermann, Ingrid; Linz, Dominik; Cremers, Bodo; Laufs, Ulrich; Neuberger, Hans-Ruprecht; Böhm, Michael

    2013-09-10

    Renal sympathetic denervation (RDN) reduces sympathetic activity and blood pressure (BP) in patients with resistant hypertension. The present study aimed to investigate the effects of RDN on HR and other electrocardiographic parameters. 136 patients aged 62.2 ± 0.8 years (58% male, BP 177 ± 2/93 ± 1 mmHg) with resistant hypertension underwent RDN. BP and a 12-lead electrocardiogram (ECG) were recorded before, 3 months (n=127), and 6 months (n=88) after RDN. After 3 months (3M) and 6 months (6M), systolic BP was reduced by 25.5 ± 2.4 mmHg (p<0.0001) and 28.1 ± 3 mmHg (p<0.0001). HR at baseline was 66.1 ± 1 beats per minute (bpm) and was reduced by 2.6 ± 0.8 bpm after 3 months (p=0.001) and 2.1 ± 1.1 bpm after 6 months (p=0.046). Patients with HR at baseline between 60-71 bpm and ≥ 71 bpm had a reduction of 2.9 ± 7.6 bpm (p=0.008) and 9.0 ± 8.6 bpm (p<0.0001), respectively, whereas in patients with baseline HR<60 bpm HR slightly increased after 3 months (2.7 ± 8.4 bpm; p=0.035). Neither baseline HR nor change of HR correlated with the reduction of systolic BP. The PR interval was prolonged by 11.3 ± 2.5 ms (p<0.0001) and 10.3 ± 2.5 ms (p<0.0001) at 3 and 6 months after RDN, respectively. Renal sympathetic denervation reduced heart rate and the PR interval as indicators of cardiac autonomic activity. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  16. Respiratory rates measured by a standardised clinical approach, ward staff, and a wireless device.

    PubMed

    Granholm, A; Pedersen, N E; Lippert, A; Petersen, L F; Rasmussen, L S

    2016-11-01

    Respiratory rate is among the first vital signs to change in deteriorating patients. The aim was to investigate the agreement between respiratory rate measurements by three different methods. This prospective observational study included acutely admitted adult patients in a medical ward. Respiratory rate was measured by three methods: a standardised approach over 60 s while patients lay still and refrained from talking, by ward staff and by a wireless electronic patch (SensiumVitals). The Bland-Altman method was used to compare measurements and three breaths per minute (BPM) was considered a clinically relevant difference. We included 50 patients. The mean difference between the standardised approach and the electronic measurement was 0.3 (95% CI: -1.4 to 2.0) BPM; 95% limits of agreement were -11.5 (95% CI: -14.5 to -8.6) and 12.1 (95% CI: 9.2 to 15.1) BPM. Removal of three outliers with huge differences lead to a mean difference of -0.1 (95% CI: -0.7 to 0.5) BPM and 95% limits of agreement of -4.2 (95% CI: -5.3 to -3.2) BPM and 4.0 (95% CI: 2.9 to 5.0) BPM. The mean difference between staff and electronic measurements was 1.7 (95% CI: -0.5 to 3.9) BPM; 95% limits of agreement were -13.3 (95% CI: -17.2 to -9.5) BPM and 16.8 (95% CI: 13.0 to 20.6) BPM. A concerning lack of agreement was found between a wireless monitoring system and a standardised clinical approach. Ward staff's measurements also seemed to be inaccurate. © 2016 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

  17. Towards a better understanding of honeycomb alternating magnetic networks.

    PubMed

    Marino, Nadia; Armentano, Donatella; De Munno, Giovanni; Lloret, Francesc; Cano, Joan; Julve, Miguel

    2015-06-28

    Two new two-dimensional homometallic compounds {[M2(bpm)(ox)2]n·5nH2O} with M = Co(II) (1) and Zn(II) (2) and the mononuclear nickel(II) complex [Ni(bpm)2(ox)]·2H2O (3) [bpm = 2,2'-bipyrimidine and ox = oxalate] have been prepared and structurally characterized. 1 and 2 are isostructural compounds whose structures are made up of oxalate-bridged M(II) cations cross-linked by bis-bidentate bpm molecules to afford a honeycomb layered network extending in the crystallographic ab plane. The layers are eclipsed along the crystallographic c axis and show graphitic-like interactions between the bpm rings. The three-dimensional supramolecular network deriving from such interactions is characterized by hexagonal-shaped channels extending in the same direction. Each M(II) ion in 1 and 2 is tris-chelated with four oxygen atoms from two oxalate groups and two bpm-nitrogen atoms building a distorted octahedral surrounding. The reduced values of the angles subtended by the bis-chelating bpm [77.69(8) (1) and 76.59(8)° (2)] and oxalate [79.69(6) (1) and 80.01(5)° (2)] are the main factors accounting for this distortion. The values of the metal-metal separation through bridging bpm are 5.6956(7) (1) and 5.7572(9) Å (2), whereas those across the bis-bidentate oxalate are 5.4306(4) (1) and 5.4058(5) Å (2). 3 is a neutral mononuclear nickel(II) complex where each metal ion is six-coordinate with four nitrogen atoms from two bpm ligands in a cis arrangement and two oxalate-oxygen atoms building a somewhat distorted octahedral surrounding. The values of the angles subtended at the nickel(II) ion by bpm and oxalate are 78.14(4) and 80.95(5)°, respectively. The magnetic properties of 1 have been investigated in the temperature range 1.9-295 K. They are typical of an overall antiferromagnetic coupling with a maximum of the magnetic susceptibility at 22.0 K. The analysis of the susceptibility data of 1 through an effective spin Hamiltonian allowed a satisfactory simulation in the temperature range 10-295 K with the best-fit parameters λ = -110 cm(-1), α = 1.1, |Δ| = 400 cm(-1), J(ox) = -11.1 cm(-1) and J(bpm) = -5.0 cm(-1). The values of the antiferromagnetic coupling through bpm and ox in 1 have also been supported by electronic structure calculations based on Density Functional Theory (DFT) and they compare well with those reported in the literature for bpm-bridged dicobalt(II) complexes and oxalate-bridged cobalt(II) chains.

  18. Measured maximal heart rates compared to commonly used age-based prediction equations in the Heritage Family Study.

    PubMed

    Sarzynski, M A; Rankinen, T; Earnest, C P; Leon, A S; Rao, D C; Skinner, J S; Bouchard, C

    2013-01-01

    The purpose of this study was to examine how well two commonly used age-based prediction equations for maximal heart rate (HRmax ) estimate the actual HRmax measured in Black and White adults from the HERITAGE Family Study. A total of 762 sedentary subjects (39% Black, 57% Females) from HERITAGE were included. HRmax was measured during maximal exercise tests using cycle ergometers. Age-based HRmax was predicted using the Fox (220-age) and Tanaka (208 - 0.7 × age) formulas. The standard error of estimate (SEE) of predicted HRmax was 12.4 and 11.4 bpm for the Fox and Tanaka formulas, respectively, indicating a wide-spread of measured-HRmax values are compared to their age-predicted values. The SEE (shown as Fox/Tanaka) was higher in Blacks (14.4/13.1 bpm) and Males (12.6/11.7 bpm) compared to Whites (11.0/10.2 bpm) and Females (12.3/11.2 bpm) for both formulas. The SEE was higher in subjects above the BMI median (12.8/11.9 bpm) and below the fitness median (13.4/12.4 bpm) when compared to those below the BMI median (12.2/11.0 bpm) and above the fitness median (11.4/10.3) for both formulas. Our findings show that based on the SEE, the prevailing age-based estimated HRmax equations do not precisely predict an individual's measured-HRmax . Copyright © 2013 Wiley Periodicals, Inc.

  19. Small-strip Thin Gap Chambers for the muon spectrometer upgrade of the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Perez Codina, E.; ATLAS Muon Collaboration

    2016-07-01

    The ATLAS muon system upgrade to be installed during the LHC long shutdown in 2018/19, the so-called New Small Wheel (NSW), is designed to cope with the increased instantaneous luminosity in LHC Run 3. The small-strip Thin Gap Chambers (sTGC) will provide the NSW with a fast trigger and high precision tracking. The construction protocol has been validated by test beam experiments on a full-size prototype sTGC detector, showing the performance requirements are met. The intrinsic spatial resolution for a single layer has been found to be about 45 μm for a perpendicular incident angle, and the transition region between pads has been measured to be about 4 mm.

  20. CuOF: an electrical to optical interface for the upgrade of the CMS muon Drift Tubes system

    NASA Astrophysics Data System (ADS)

    Dattola, D.; De Remigis, P.; Maselli, S.; Mazza, G.; Rotondo, F.; Wheadon, R.

    2013-02-01

    The upgrade of the Drift Tube system of the CMS experiment foresee the relocation of the electronics actually sitting on the racks beside the magnet from the cavern to the counting room. It is thus required to convert the signals from electrical to optical, for a total number of 3500 channels that run at up to 480 Mb/s. A Copper to Optical Fiber board is currently under design. The board is divided into a mother board, which hosts the slow control system based on Field Programmable Gate Array, and four mezzanine cards, each with 8 conversion channels. A prototype of the mezzanine board has been designed and tested under irradiation.

  1. Small Aperture BPM to Quadrupole Assembly Tolerance Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fong, K. W.

    2010-12-07

    The LCLS injector and linac systems utilize a series of quadrupole magnets with a beam position monitor (BPM) captured in the magnet pole tips. The BPM measures the electron beam position by comparing the electrical signal from 4 electrodes and interpolating beam position from these signals. The manufacturing tolerances of the magnet and BPM are critical in determining the mechanical precision of the electrodes relative to the nominal electron beam Z-axis. This study evaluates the statistical uncertainty of the electrodes center axis relative to the nominal electron beam axis.

  2. RanBPM: a potential therapeutic target for modulating diverse physiological disorders.

    PubMed

    Das, Soumyadip; Suresh, Bharathi; Kim, Hyongbum Henry; Ramakrishna, Suresh

    2017-12-01

    The Ran-binding protein microtubule-organizing center (RanBPM) is a highly conserved nucleocytoplasmic protein involved in a variety of intracellular signaling pathways that control diverse cellular functions. RanBPM interacts with proteins that are linked to various diseases, including Alzheimer's disease (AD), schizophrenia (SCZ), and cancer. In this article, we define the characteristics of the scaffolding protein RanBPM and focus on its interaction partners in diverse physiological disorders, such as neurological diseases, fertility disorders, and cancer. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. Overview of recent trends and developments for BPM systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wendt, M.; /Fermilab

    2011-08-01

    Beam position monitoring (BPM) systems are the workhorse of beam diagnostics for almost any kind of charged particle accelerator: linear, circular or transport-lines, operating with leptons, hadrons or heavy ions. BPMs are essential for beam commissioning, accelerator fault analysis and trouble shooting, machine optics, as well as lattice measurements, and finally, for accelerator optimization, in order to achieve the ultimate beam quality. This presentation summarizes the efforts of the beam instrumentation community on recent developments and advances on BPM technologies, i.e. BPM pickup monitors and front-end electronics (analog and digital). Principles, examples, and state-of-the-art status on various BPM techniques, servingmore » hadron and heavy ion machines, sync light synchrotron's, as well as electron linacs for FEL or HEP applications are outlined.« less

  4. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells

    PubMed Central

    Singh, Satyendra; Klarmann, Kimberly D.; Coppola, Vincenzo; Keller, Jonathan R.; Tessarollo, Lino

    2016-01-01

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies. PMID:27835883

  5. RanBPM (RanBP9) regulates mouse c-Kit receptor level and is essential for normal development of bone marrow progenitor cells.

    PubMed

    Puverel, Sandrine; Kiris, Erkan; Singh, Satyendra; Klarmann, Kimberly D; Coppola, Vincenzo; Keller, Jonathan R; Tessarollo, Lino

    2016-12-20

    c-Kit is a tyrosine kinase receptor important for gametogenesis, hematopoiesis, melanogenesis and mast cell biology. Dysregulation of c-Kit function is oncogenic and its expression in the stem cell niche of a number of tissues has underlined its relevance for regenerative medicine and hematopoietic stem cell biology. Yet, very little is known about the mechanisms that control c-Kit protein levels. Here we show that the RanBPM/RanBP9 scaffold protein binds to c-Kit and is necessary for normal c-Kit protein expression in the mouse testis and subset lineages of the hematopoietic system. RanBPM deletion causes a reduction in c-Kit protein but not its mRNA suggesting a posttranslational mechanism. This regulation is specific to the c-Kit receptor since RanBPM reduction does not affect other membrane proteins examined. Importantly, in both mouse hematopoietic system and testis, RanBPM deficiency causes defects consistent with c-Kit loss of expression suggesting that RanBPM is an important regulator of c-Kit function. The finding that this regulatory mechanism is also present in human cells expressing endogenous RanBPM and c-Kit suggests a potential new strategy to target oncogenic c-Kit in malignancies.

  6. Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) for WFIRST/AFTA

    NASA Technical Reports Server (NTRS)

    Gong, Qian; McElwain, Michael; Greeley, Bradford; Grammer, Bryan; Marx, Catherine; Memarsadeghi, Nargess; Hilton, George; Perrin, Marshall; Sayson, Llop; Domingo, Jorge; hide

    2015-01-01

    Prototype Imaging Spectrograph for Coronagraphic Exoplanet Studies (PISCES) is a prototype lenslet array based integral field spectrometer (IFS) designed for high contrast imaging of extrasolar planets. PISCES will be used to advance the technology readiness of the high contrast IFS baselined on the Wide-Field InfraRed Survey TelescopeAstrophysics Focused Telescope Assets (WFIRSTAFTA) coronagraph instrument. PISCES will be integrated into the high contrast imaging testbed (HCIT) at the Jet Propulsion Laboratory and will work with both the Hybrid Lyot Coronagraph (HLC) and the Shaped Pupil Coronagraph (SPC). We will present the PISCES optical design, including the similarities and differences of lenslet based IFSs to normal spectrometers, the trade-off between a refractive design and reflective design, as well as the compatibility to upgrade from the current 1k x 1k detector array to 4k x 4k detector array. The optical analysis, alignment plan, and mechanical design of the instrument will be discussed.

  7. Design, prototyping, and testing of a compact superconducting double quarter wave crab cavity

    NASA Astrophysics Data System (ADS)

    Xiao, Binping; Alberty, Luis; Belomestnykh, Sergey; Ben-Zvi, Ilan; Calaga, Rama; Cullen, Chris; Capatina, Ofelia; Hammons, Lee; Li, Zenghai; Marques, Carlos; Skaritka, John; Verdu-Andres, Silvia; Wu, Qiong

    2015-04-01

    We proposed a novel design for a compact superconducting crab cavity with a double quarter wave (DQWCC) shape. After fabrication and surface treatments, this niobium proof-of-principle cavity was tested cryogenically in a vertical cryostat. The cavity is extremely compact yet has a low frequency of 400 MHz, an essential property for service in the Large Hadron Collider luminosity upgrade. The cavity's electromagnetic properties are well suited for this demanding task. The demonstrated deflecting voltage of 4.6 MV is well above the required 3.34 MV for a crab cavity in the future High Luminosity LHC. In this paper, we present the design, prototyping, and results from testing the DQWCC.

  8. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    NASA Astrophysics Data System (ADS)

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A.; won Jang, Si; Vinokurov, Nikolay A.; Jeong, Young UK; Hee Park, Seong; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  9. [Relationship between baseline heart rate and all-cause death in general population].

    PubMed

    Chen, Ji; Chen, Shuo-hua; Liu, Xing; Zhang, Cai-feng; Yao, Tao; Yang, Hui; Wang, Jian-li; Wu, Shou-ling

    2013-06-01

    To investigate the relationship between baseline heart rate(HR) and all-cause death(ACD)in general population. 93 716 workers with heart rate between 40 bpm/min-120 bpm/min and without histories of stroke were selected from the '2006-2007 health examination records' in Kailuan and completed the electrocardiogram exam. Related information were also gathered. These subjects were followed up from July 2006 to December 2010, with the mean time of follow-up as 47.5±4.3 months. During the follow-up period, the occurrence of all-cause death was observed every half a year. (1)The lowest cumulative mortality rate was 1.61% in the group with 60-69 bpm/min. The lowest cumulative mortality rate was 1.78% in the group of 60-69 bpm/min in men. There was no death events observed in women with less than 50 bpm/min and the lowest cumulative mortality rate was 0.60% in the group of 80-89 bpm/min in women. (2)Data from Cox proportional hazard regression analysis showed that the RR(95%CI)of cumulative mortality rates in general population were 1.187 (1.039-1.336), 1.392(1.185-1.636), 1.733(1.404-2.139)and 2.716 (2.171-3.398)in the groups of 70-79, 80-89, 90-99 and ≥100 bpm/min, respectively. The RRs (95% CI) of cumulative mortality in men were 1.227(1.067-1.410), 1.481(1.254-1.750), 1.754 (1.406-2.188)and 2.831 (2.245-3.571) respectively. In women, when comparing with the group of 80-89 bpm/min, the RRs (95%CI)of all-cause death were 0.671(0.568-0.793), 0.825(0.703-0.970) and 1.925 (1.512-2.453)respectively in the groups of 60-69, 70-79 and ≥100 bpm/min. When HR exceeding ≥70 bpm/min, the increase of HR would also increase the rate of ACD. Results of our study also showed a J-shaped curve relation between HR and mortality.

  10. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser.

    PubMed

    Noh, Seon Yeong; Kim, Eun-San; Hwang, Ji-Gwang; Heo, A; Jang, Si won; Vinokurov, Nikolay A; Jeong, Young U K; Park, Seong Hee; Jang, Kyu-Ha

    2015-01-01

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using an oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was -39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.

  11. Development of an S-band cavity-type beam position monitor for a high power THz free-electron laser

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Noh, Seon Yeong; Kim, Eun-San, E-mail: eskim1@knu.ac.kr; Hwang, Ji-Gwang

    2015-01-15

    A cavity-type beam position monitor (BPM) has been developed for a compact terahertz (THz) free-electron laser (FEL) system and ultra-short pulsed electron Linac system at the Korea Atomic Energy Research Institute (KAERI). Compared with other types of BPMs, the cavity-type BPM has higher sensitivity and faster response time even at low charge levels. When electron beam passes through the cavity-type BPM, it excites the dipole mode of the cavity of which amplitude depends linearly on the beam offset from the center of the cavity. Signals from the BPM were measured as a function of the beam offset by using anmore » oscilloscope. The microtron accelerator for the KAERI THz FEL produces the electron beam with an energy of 6.5 MeV and pulse length of 5 μs with a micropulse of 10-20 ps at the frequency of 2.801 GHz. The macropulse beam current is 40 mA. Because the microtron provides multi-bunch system, output signal would be the superposition of each single bunch. So high output signal can be obtained from superposition of each single bunch. The designed position resolution of the cavity-type BPM in multi-bunch is submicron. Our cavity-type BPM is made of aluminum and vacuum can be maintained by indium sealing without brazing process, resulting in easy modification and cost saving. The resonance frequency of the cavity-type BPM is 2.803 GHz and the cavity-type BPM dimensions are 200 × 220 mm (length × height) with a pipe diameter of 38 mm. The measured position sensitivity was 6.19 (mV/mm)/mA and the measured isolation between the X and Y axis was −39 dB. By measuring the thermal noise of system, position resolution of the cavity-type BPM was estimated to be less than 1 μm. In this article, we present the test results of the S-band cavity-type BPM and prove the feasibility of the beam position measurement with high resolution using this device.« less

  12. Influences on Satisfaction with Reconstructed Breasts and Intimacy in Younger Women Following Bilateral Prophylactic Mastectomy: a Qualitative Analysis.

    PubMed

    Glassey, Rachael; O'Connor, Moira; Ives, Angela; Saunders, Christobel; Hardcastle, Sarah J

    2018-04-30

    The aim of this study was to explore the influences on satisfaction with reconstructed breasts and intimacy following bilateral prophylactic mastectomy (BPM) in younger women (< 35) with a strong family history of breast cancer. Twenty-six women who had undergone BPM between 1 and6 years ago were recruited from New Zealand and Australia through a genetics clinic, registry, research cohort, and online (M age  = 31). Twenty-three were BRCA mutation carriers. Qualitative interviews guided by interpretative phenomenological analysis were conducted. Four themes were identified: satisfaction with breasts before surgery, outcome expectations, type of mastectomy, and open communication. Women who liked their breasts pre-BPM appeared less satisfied with their reconstructed breasts post-surgery, and women who disliked their breasts before BPM were more satisfied with their reconstructed breasts. Women with unrealistic expectations concerning the look and feel of reconstructed breasts were often unhappy with their reconstructed breasts and felt they did not meet their expectations. Unrealistic photos of breast reconstruction and satisfactory communication of realistic outcome expectations by surgeons or psychologists also appeared to influence satisfaction. Communication with partners prior to BPM appeared to improve satisfaction with intimacy post-BPM. The findings suggest that satisfaction with reconstructed breasts for younger women post-BPM appeared to be influenced by realistic outcome expectations and communication with others concerning reconstructed breast appearance and intimacy post-BPM. Implications for practice include discussion of realistic reconstructed breast appearance, referral to a psychologist to discuss sensitive issues, and accurate communication of surgical risks and consequences.

  13. A diminished aortic-cardiac reflex during hypotension in aerobically fit young men

    NASA Technical Reports Server (NTRS)

    Shi, X.; Crandall, C. G.; Potts, J. T.; Williamson, J. W.; Foresman, B. H.; Raven, P. B.

    1993-01-01

    We compared the aortic-cardiac baroreflex sensitivity in eight average fit (AF: VO2max = 44.7 +/- 1.3 ml.kg-1 x min-1) and seven high fit (HF: VO2max = 64.1 +/- 1.7 ml.min-1 x kg-1) healthy young men during hypotension elicited by steady state sodium nitroprusside (SN) infusion. During SN mean arterial pressure (MAP) was similarly decreased in AF (-12.6 +/- 1.0 mm Hg) and HF (-12.1 +/- 1.1 mm Hg). However, the increases in heart rate (HR) were less (P < 0.023) in HF (15 +/- 3 bpm) than AF (25 +/- 1 bpm). When sustained neck suction (NS, -22 +/- 1 torr in AF and -20 +/- 1 torr in HF, P > 0.05) was applied to counteract the decreased carotid sinus transmural pressure during SN, thereby isolating the aortic baroreceptors, the increased HR remained less (P < 0.021) in HF (8 +/- 2 bpm) than AF (16 +/- 2 bpm). During both SN infusion and SN+NS, the calculated gains (i.e., delta HR/delta MAP) were significantly greater in AF (2.1 +/- 0.3 and 1.3 +/- 0.2 bpm.mm Hg-1) than HF (1.2 +/- 0.2 and 0.6 +/- 0.2 bpm.mm Hg-1). However, the estimated carotid-cardiac baroreflex sensitivity (i.e., the gain difference between the stage SN and SN + NS) was not different between AF (0.7 +/- 0.2 bpm.mm Hg-1) and HF (0.6 +/- 0.1 bpm.mm Hg-1). These data indicated that the aortic-cardiac baroreflex sensitivity during hypotension was significantly diminished with endurance exercise training.

  14. Statistical baseline assessment in cardiotocography.

    PubMed

    Agostinelli, Angela; Braccili, Eleonora; Marchegiani, Enrico; Rosati, Riccardo; Sbrollini, Agnese; Burattini, Luca; Morettini, Micaela; Di Nardo, Francesco; Fioretti, Sandro; Burattini, Laura

    2017-07-01

    Cardiotocography (CTG) is the most common non-invasive diagnostic technique to evaluate fetal well-being. It consists in the recording of fetal heart rate (FHR; bpm) and maternal uterine contractions. Among the main parameters characterizing FHR, baseline (BL) is fundamental to determine fetal hypoxia and distress. In computerized applications, BL is typically computed as mean FHR±ΔFHR, with ΔFHR=8 bpm or ΔFHR=10 bpm, both values being experimentally fixed. In this context, the present work aims: to propose a statistical procedure for ΔFHR assessment; to quantitatively determine ΔFHR value by applying such procedure to clinical data; and to compare the statistically-determined ΔFHR value against the experimentally-determined ΔFHR values. To these aims, the 552 recordings of the "CTU-UHB intrapartum CTG database" from Physionet were submitted to an automatic procedure, which consisted in a FHR preprocessing phase and a statistical BL assessment. During preprocessing, FHR time series were divided into 20-min sliding windows, in which missing data were removed by linear interpolation. Only windows with a correction rate lower than 10% were further processed for BL assessment, according to which ΔFHR was computed as FHR standard deviation. Total number of accepted windows was 1192 (38.5%) over 383 recordings (69.4%) with at least an accepted window. Statistically-determined ΔFHR value was 9.7 bpm. Such value was statistically different from 8 bpm (P<;10 -19 ) but not from 10 bpm (P=0.16). Thus, ΔFHR=10 bpm is preferable over 8 bpm because both experimentally and statistically validated.

  15. Resting heart rate associates with one-year risk of major adverse cardiovascular events in patients with acute coronary syndrome after percutaneous coronary intervention.

    PubMed

    Wang, Shao-Li; Wang, Cheng-Long; Wang, Pei-Li; Xu, Hao; Du, Jian-Peng; Zhang, Da-Wu; Gao, Zhu-Ye; Zhang, Lei; Fu, Chang-Geng; Chen, Ke-Ji; Shi, Da-Zhuo

    2016-03-01

    The study was to access the association between resting heart rate (RHR) and one-year risk of major adverse cardiovascular events (MACE) in acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). Patients with ACS after PCI (n = 808) were prospectively followed-up for MACE. RHR was obtained from electrocardiogram. MACE was defined as a composite of cardiac death, nonfatal recurrent myocardial infarction, ischemic-driven revascularization, and ischemic stroke. The association between RHR and one-year risk of MACE was assessed using Cox proportional hazards regression model. Compared with patients with RHR >76 bpm, the adjusted hazard ratio (AHR) was 0.51 (95% confidence intervals [CI]: 0.23-1.14; P = 0.100) for patients with RHR < 61 bpm, and 0.44 (95%CI: 0.23-0.85; P = 0.014) for those with RHR 61-76 bpm. For patients with RHR ≥ 61 bpm, an increase of 10 bpm in RHR was associated with an increase by 38.0% in the risk of MACE (AHR: 1.38; 95% CI: 1.04-1.83; P = 0.026). ACS patients after PCI with RHR >76 bpm were at higher risk of MACE during one-year follow-up compared with patients with RHR 61-76 bpm. An elevated RHR ≥ 61 bpm was associated with increased risk of one-year MACE in ACS patients. © 2015 by the Society for Experimental Biology and Medicine.

  16. Resting heart rate associates with one-year risk of major adverse cardiovascular events in patients with acute coronary syndrome after percutaneous coronary intervention

    PubMed Central

    Wang, Shao-Li; Wang, Cheng-Long; Wang, Pei-Li; Xu, Hao; Du, Jian-Peng; Zhang, Da-Wu; Gao, Zhu-Ye; Zhang, Lei; Fu, Chang-Geng; Chen, Ke-Ji

    2015-01-01

    The study was to access the association between resting heart rate (RHR) and one-year risk of major adverse cardiovascular events (MACE) in acute coronary syndrome (ACS) patients after percutaneous coronary intervention (PCI). Patients with ACS after PCI (n = 808) were prospectively followed-up for MACE. RHR was obtained from electrocardiogram. MACE was defined as a composite of cardiac death, nonfatal recurrent myocardial infarction, ischemic-driven revascularization, and ischemic stroke. The association between RHR and one-year risk of MACE was assessed using Cox proportional hazards regression model. Compared with patients with RHR >76 bpm, the adjusted hazard ratio (AHR) was 0.51 (95% confidence intervals [CI]: 0.23–1.14; P = 0.100) for patients with RHR < 61 bpm, and 0.44 (95%CI: 0.23–0.85; P = 0.014) for those with RHR 61–76 bpm. For patients with RHR ≥ 61 bpm, an increase of 10 bpm in RHR was associated with an increase by 38.0% in the risk of MACE (AHR: 1.38; 95% CI: 1.04–1.83; P = 0.026). ACS patients after PCI with RHR >76 bpm were at higher risk of MACE during one-year follow-up compared with patients with RHR 61–76 bpm. An elevated RHR ≥ 61 bpm was associated with increased risk of one-year MACE in ACS patients. PMID:26585407

  17. Sensors for the End-cap prototype of the Inner Tracker in the ATLAS Detector Upgrade

    NASA Astrophysics Data System (ADS)

    Benítez, V.; Ullán, M.; Quirion, D.; Pellegrini, G.; Fleta, C.; Lozano, M.; Sperlich, D.; Hauser, M.; Wonsak, S.; Parzefall, U.; Mahboubi, K.; Kuehn, S.; Mori, R.; Jakobs, K.; Bernabeu, J.; García, C.; Lacasta, C.; Marco, R.; Rodriguez, D.; Santoyo, D.; Solaz, C.; Soldevila, U.; Ariza, D.; Bloch, I.; Diez, S.; Gregor, I. M.; Keller, J.; Lohwasser, K.; Peschke, R.; Poley, L.; Brenner, R.; Affolder, A.

    2016-10-01

    The new silicon microstrip sensors of the End-cap part of the HL-LHC ATLAS Inner Tracker (ITk) present a number of challenges due to their complex design features such as the multiple different sensor shapes, the varying strip pitch, or the built-in stereo angle. In order to investigate these specific problems, the "petalet" prototype was defined as a small End-cap prototype. The sensors for the petalet prototype include several new layout and technological solutions to investigate the issues, they have been tested in detail by the collaboration. The sensor description and detailed test results are presented in this paper. New software tools have been developed for the automatic layout generation of the complex designs. The sensors have been fabricated, characterized and delivered to the institutes in the collaboration for their assembly on petalet prototypes. This paper describes the lessons learnt from the design and tests of the new solutions implemented on these sensors, which are being used for the full petal sensor development. This has resulted in the ITk strip community acquiring the necessary expertise to develop the full End-cap structure, the petal.

  18. Syntheses, crystal structures, and magnetic properties of the oxalato-bridged mixed-valence complexes (FeII(bpm)3]2[FeIII2(ox)5].8H2O and FeII(bpm)3Na(H2O)2Fe(ox)(3).4H2O (bpm = 2,2'-bipyrimidine).

    PubMed

    Armentano, D; De Munno, G; Faus, J; Lloret, F; Julve, M

    2001-02-12

    The preparation and crystal structures of two oxalato-bridged FeII-FeIII mixed-valence compounds, [FeII(bpm)3]2[FeIII2(ox)5].8H2O (1) and FeII(bpm)3Na(H2O)2FeIII(ox)(3).4H2O (2) (bpm = 2,2'-bipyrimidine; ox = oxalate dianion) are reported here. Complex 1 crystallizes in the triclinic system, space group P1, with a = 10.998(2) A, b = 13.073(3) A, c = 13.308(3) A, alpha = 101.95(2) degrees, beta = 109.20(2) degrees, gamma = 99.89(2) degrees, and Z = 1. Complex 2 crystallizes in the monoclinic system, space group P2(1)/c, with a = 12.609(2) A, b = 19.670(5) A, c = 15.843(3) A, beta = 99.46(1) degrees, and Z = 4. The structure of complex 1 consists of centrosymmetric oxalato-bridged dinuclear high-spin iron(III) [Fe2(ox)5]2- anions, tris-chelated low-spin iron(II) [Fe(bpm)3]2+ cations, and lattice water molecules. The iron atoms are hexacoordinated: six oxygen atoms (iron(III)) from two bidentate and one bisbidentate oxalato ligands and six nitrogen atoms (iron(II)) from three bidentate bpm groups. The Fe(III)-O(ox) and Fe(II)-N(bpm) bond distances vary in the ranges 1.967(3)-2.099(3) and 1.967(4)-1.995(3) A, respectively. The iron(III)-iron(III) separation across the bridging oxalato is 5.449(2) A, whereas the shortest intermolecular iron(III)-iron(II) distance is 6.841(2) A. The structure of complex 2 consists of neutral heterotrinuclear Fe(bpm)2Na(H2O)2Fe(ox)3 units and water molecules of crystallization. The tris-chelated low-spin iron(II) ([Fe(bpm)3]2+) and high-spin iron(III) ([Fe(ox)3]3-) entities act as bidentate ligands (through two bpm-nitrogen and two oxalato-oxygen atoms, respectively) toward the univalent sodium cation, yielding the trinuclear (bpm)2Fe(II)-bpm-Na(I)-ox-Fe(III)(ox)2 complex. Two cis-coordinated water molecules complete the distorted octahedral surrounding of the sodium atom. The ranges of the Fe(II)-N(bpm) and Fe(III)-O(ox) bond distances [1.968(6)-1.993(5) and 1.992(6)-2.024(6) A, respectively] compare well with those observed in 1. The Na-N(bpm) bond lengths (2.548(7) and 2.677(7) A) are longer than those of Na-O(ox) (2.514(7) and 2.380(7) A) and Na-O(water) (2.334(15) and 2.356(12) A). The intramolecular Fe(II)...Fe(III) separation is 6.763(2) A, whereas the shortest intermolecular Fe(II)...Fe(II) and Fe(III)...Fe(III) distances are 8.152(2) and 8.992(2) A, respectively. Magnetic susceptibility measurements in the temperature range 2.0-290 K for 1 reveal that the high-spin iron(III) ions are antiferromagnetically coupled (J = -6.6 cm-1, the Hamiltonian being defined as H = -JS1.S2). The magnitude of the antiferromagnetic coupling through the bridging oxalato in the magneto-structurally characterized family of formula [M2(ox)5](2m-10)+ (M = Fe(III) (1), Cr(III), and Ni(II)) is analyzed and discussed by means of a simple orbital model.

  19. Developing cloud-based Business Process Management (BPM): a survey

    NASA Astrophysics Data System (ADS)

    Mercia; Gunawan, W.; Fajar, A. N.; Alianto, H.; Inayatulloh

    2018-03-01

    In today’s highly competitive business environment, modern enterprises are dealing difficulties to cut unnecessary costs, eliminate wastes and delivery huge benefits for the organization. Companies are increasingly turning to a more flexible IT environment to help them realize this goal. For this reason, the article applies cloud based Business Process Management (BPM) that enables to focus on modeling, monitoring and process management. Cloud based BPM consists of business processes, business information and IT resources, which help build real-time intelligence systems, based on business management and cloud technology. Cloud computing is a paradigm that involves procuring dynamically measurable resources over the internet as an IT resource service. Cloud based BPM service enables to address common problems faced by traditional BPM, especially in promoting flexibility, event-driven business process to exploit opportunities in the marketplace.

  20. Maximal heart rate in soccer players: measured versus age-predicted.

    PubMed

    Nikolaidis, Pantelis T

    2015-01-01

    Although maximal heart rate (HR max) is widely used to assess exercise intensity in sport training, and particularly in soccer, there are limited data with regards to the use of age-based prediction equations of HR max in soccer players. The aim of this study was to compare the measured-HR max with two prediction equations (Fox-HR max = 220 - age and Tanaka-HR max = 208 - 0.7 × age) in soccer players. Adolescent (n = 162, 15.8 ± 1.5 years) and adult players (n = 158, 23.4 ± 4.6 years), all members of competitive clubs, voluntarily performed a graded exercise field test (Conconi protocol) to assess HR max . The measured-HR max (197.6 ± 9.4 bpm in total, 200.2 ± 7.9 bpm in adolescent players, and 195.0 ± 10.0 bpm in adult players) was explained by the formula HR max = 212.3 - 0.75 × age (r = -0.41, standard error of the estimate = 8.6). In the total sample, Fox-HR max overestimated measured-HR max [mean difference (95% confidence intervals) = 2.8 bpm (1.6; 3.9)], while Tanaka-HR max underestimated HR max [-3.3 bpm (-4.5; -2.2)]. In adolescents, Fox-HR max overestimated measured-HR max [4.0 bpm (2.5; 5.5)] and Tanaka-HR max underestimated HR max [- 3.2 bpm (-4.7; -1.8)]. In adults, Tanaka-HR max underestimated HR max [-5.0 bpm (-5.3; -4.7)], while there was not any difference between Fox-HR max and measured-HR max [1.6 bpm (-3.4; 0.2)]. The results of this study failed to validate two widely used prediction equations in a large sample of soccer players, indicating the need for a sport-specific equation. On the other hand, the new equation that we presented should be investigated further by future studies before being adopted by coaches and fitness trainers.

  1. Heart rate as an independent risk factor in patients with multiple organ dysfunction: a prospective, observational study.

    PubMed

    Hoke, Robert S; Müller-Werdan, Ursula; Lautenschläger, Christine; Werdan, Karl; Ebelt, Henning

    2012-02-01

    To study the association between baseline heart rate and outcome in patients with multiple organ dysfunction (MODS) as well as the course of heart rate over the first 4 days during MODS. Prospective observational study in 89 patients with MODS, defined as an APACHE-II score ≥20. Baseline heart rate (HR(0)) was determined over a 60-minute period at the time of MODS diagnosis. 28-day all-cause mortality was the primary endpoint of the study, a fall of the APACHE-II score by 4 points or more from day 0 to day 4 constituted the secondary endpoint. Hazard ratios for heart rate of 90 beats per minute (bpm) or greater relative to less than 90 bpm were calculated using Cox proportional hazards model and adjusted for confounding variables. Median baseline heart rate was 83 bpm in survivors and 92 bpm in non-survivors (p = 0.048). 28-day mortality was 32 and 61% in patients with HR(0) < 90 bpm and HR(0) ≥ 90 bpm, respectively. The adjusted hazard ratio for 28-day mortality was 2.30 (95% confidence interval 1.21-4.36, p = 0.001) for HR(0) ≥ 90 bpm relative to HR(0) < 90 bpm. No correlation was found between baseline heart rate and the secondary endpoint. From day 0 to day 4, heart rate remained elevated in all patients, as well as in survivors and non-survivors. A heart rate ≥90 bpm at the time of MODS diagnosis is an independent risk factor for increased 28-day mortality. As in patients with cardiovascular conditions such as coronary heart disease or chronic heart failure, heart rate might constitute a target for heart rate-lowering therapy in the narrow initial treatment window of MODS.

  2. Beam position reconstruction for the g2p experiment in Hall A at Jefferson lab

    NASA Astrophysics Data System (ADS)

    Zhu, Pengjia; Allada, Kalyan; Allison, Trent; Badman, Toby; Camsonne, Alexandre; Chen, Jian-ping; Cummings, Melissa; Gu, Chao; Huang, Min; Liu, Jie; Musson, John; Slifer, Karl; Sulkosky, Vincent; Ye, Yunxiu; Zhang, Jixie; Zielinski, Ryan

    2016-02-01

    Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. Before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve the required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. The calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.

  3. A beating heart cell model to predict cardiotoxicity: effects of the dietary supplement ingredients higenamine, phenylethylamine, ephedrine and caffeine.

    PubMed

    Calvert, Richard; Vohra, Sanah; Ferguson, Martine; Wiesenfeld, Paddy

    2015-04-01

    Some dietary supplements may contain cardiac stimulants and potential cardiotoxins. In vitro studies may identify ingredients of concern. A beating human cardiomyocyte cell line was used to evaluate cellular effects following phenylethylamine (PEA), higenamine, ephedrine or caffeine treatment. PEA and higenamine exposure levels simulated published blood levels in humans or animals after intravenous administration. Ephedrine and caffeine levels approximated published blood levels following human oral intake. At low or midrange levels, each chemical was examined plus or minus 50 µM caffeine, simulating human blood levels reported after consumption of caffeine-enriched dietary supplements. To measure beats per minute (BPM), peak width, etc., rhythmic rise and fall in intracellular calcium levels following 30 min of treatment was examined. Higenamine 31.3 ng/ml or 313 ng/ml significantly increased BPM in an escalating manner. PEA increased BPM at 0.8 and 8 µg/ml, while 80 µg/ml PEA reduced BPM and widened peaks. Ephedrine produced a significant BPM dose response from 0.5 to 5.0 µM. Caffeine increased BPM only at a toxic level of 250 µM. Adding caffeine to PEA or higenamine but not ephedrine further increased BPM. These in vitro results suggest that additional testing may be warranted in vivo to further evaluate these effects. Published by Elsevier Ltd.

  4. High-speed, multi-channel detector readout electronics for fast radiation detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hennig, Wolfgang

    2012-06-22

    In this project, we are developing a high speed digital spectrometer that a) captures detector waveforms at rates up to 500 MSPS b) has upgraded event data acquisition with additional data buffers for zero dead time operation c) moves energy calculations to the FPGA to increase spectrometer throughput in fast scintillator applications d) uses a streamlined architecture and high speed data interface for even faster readout to the host PC These features are in addition to the standard functions in our existing spectrometers such as digitization, programmable trigger and energy filters, pileup inspection, data acquisition with energy and time stamps,more » MCA histograms, and run statistics. In Phase I, we upgraded one of our existing spectrometer designs to demonstrate the key principle of fast waveform capture using a 500 MSPS, 12 bit ADC and a Xilinx Virtex-4 FPGA. This upgraded spectrometer, named P500, performed well in initial tests of energy resolution, pulse shape analysis, and timing measurements, thus achieving item (a) above. In Phase II, we are revising the P500 to build a commercial prototype with the improvements listed in items (b)-(d). As described in the previous report, two devices were built to pursue this goal, named the Pixie-500 and the Pixie-500 Express. The Pixie-500 has only minor improvements from the Phase I prototype and is intended as an early commercial product (its production and part of its development were funded outside the SBIR). It also allows testing of the ADC performance in real applications.The Pixie-500 Express (or Pixie-500e) includes all of the improvements (b)-(d). At the end of Phase II of the project, we have tested and debugged the hardware, firmware and software of the Pixie-500 Express prototype boards delivered 12/3/2010. This proved substantially more complex than anticipated. At the time of writing, all hardware bugs have been fixed, the PCI Express interface is working, the SDRAM has been successfully tested and the SHARC DSP has been booted with preliminary code. All new ICs and circuitry on the prototype are working properly, however some of the planned firmware and software functions have not yet been completely implemented and debugged. Overall, due to the unanticipated complexity of the PCI Express interface, some aspects of the project could not be completed with the time and funds available in Phase II. These aspects will be completed in self-funded Phase III.« less

  5. 75 FR 57410 - Address Correction Notices for Letters and Flats Qualifying for Full-Service Intelligent Mail and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-21

    ... First-Class Mail[supreg], Standard Mail[supreg], and Bound Printed Matter (BPM) pieces that are eligible...-Class Mail, Standard Mail, or BPM prices. This change will coincide with the current Move Update... First-Class Mail, Standard Mail, and BPM full-service pieces. Prices for notices provided after this...

  6. MouthLab: A Tricorder Concept Optimized for Rapid Medical Assessment.

    PubMed

    Fridman, Gene Y; Tang, Hai; Feller-Kopman, David; Hong, Yang

    2015-09-01

    The goal of rapid medical assessment (RMA) is to estimate the general health of a patient during an emergency room or a doctor's office visit, or even while the patient is at home. Currently the devices used during RMA are typically "all-in-one" vital signs monitors. They require time, effort and expertise to attach various sensors to the body. A device optimized for RMA should instead require little effort or expertise to operate and be able to rapidly obtain and consolidate as much information as possible. MouthLab is a battery powered hand-held device intended to acquire and evaluate many measurements such as non-invasive blood sugar, saliva and respiratory biochemistry. Our initial prototype acquires standard vital signs: pulse rate (PR), breathing rate (BR), temperature (T), blood oxygen saturation (SpO2), blood pressure (BP), and a three-lead electrocardiogram. In our clinical study we tested the device performance against the measurements obtained with a standard patient monitor. 52 people participated in the study. The measurement errors were as follows: PR: -1.7 ± 3.5 BPM, BR: 0.4 ± 2.4 BPM, T: -0.4 ± 1.24 °F, SpO2: -0.6 ± 1.7%. BP systolic: -1.8 ± 12 mmHg, BP diastolic: 0.6 ± 8 mmHg. We have shown that RMA can be easily performed non-invasively by patients with no prior training.

  7. Beam test results of a monolithic pixel sensor in the 0.18 μm tower-jazz technology with high resistivity epitaxial layer

    NASA Astrophysics Data System (ADS)

    Mattiazzo, S.; Aimo, I.; Baudot, J.; Bedda, C.; La Rocca, P.; Perez, A.; Riggi, F.; Spiriti, E.

    2015-10-01

    The ALICE experiment at CERN will undergo a major upgrade in the second Long LHC Shutdown in the years 2018-2019; this upgrade includes the full replacement of the Inner Tracking System (ITS), deploying seven layers of Monolithic Active Pixel Sensors (MAPS). For the development of the new ALICE ITS, the Tower-Jazz 0.18 μm CMOS imaging sensor process has been chosen as it is possible to use full CMOS in the pixel and different silicon wafers (including high resistivity epitaxial layers). A large test campaign has been carried out on several small prototype chips, designed to optimize the pixel sensor layout and the front-end electronics. Results match the target requirements both in terms of performance and of radiation hardness. Following this development, the first full scale chips have been designed, submitted and are currently under test, with promising results. A telescope composed of 4 planes of Mimosa-28 and 2 planes of Mimosa-18 chips is under development at the DAFNE Beam Test Facility (BTF) at the INFN Laboratori Nazionali di Frascati (LNF) in Italy with the final goal to perform a comparative test of the full scale prototypes. The telescope has been recently used to test a Mimosa-22THRb chip (a monolithic pixel sensor built in the 0.18 μm Tower-Jazz process) and we foresee to perform tests on the full scale chips for the ALICE ITS upgrade at the beginning of 2015. In this contribution we will describe some first measurements of spatial resolution, fake hit rate and detection efficiency of the Mimosa-22THRb chip obtained at the BTF facility in June 2014 with an electron beam of 500 MeV.

  8. The Buffer Diagnostic Prototype: A fault isolation application using CLIPS

    NASA Technical Reports Server (NTRS)

    Porter, Ken

    1994-01-01

    This paper describes problem domain characteristics and development experiences from using CLIPS 6.0 in a proof-of-concept troubleshooting application called the Buffer Diagnostic Prototype. The problem domain is a large digital communications subsystems called the real-time network (RTN), which was designed to upgrade the launch processing system used for shuttle support at KSC. The RTN enables up to 255 computers to share 50,000 data points with millisecond response times. The RTN's extensive built-in test capability but lack of any automatic fault isolation capability presents a unique opportunity for a diagnostic expert system application. The Buffer Diagnostic Prototype addresses RTN diagnosis with a multiple strategy approach. A novel technique called 'faulty causality' employs inexact qualitative models to process test results. Experimental knowledge provides a capability to recognize symptom-fault associations. The implementation utilizes rule-based and procedural programming techniques, including a goal-directed control structure and simple text-based generic user interface that may be reusable for other rapid prototyping applications. Although limited in scope, this project demonstrates a diagnostic approach that may be adapted to troubleshoot a broad range of equipment.

  9. Factors associated with sinus bradycardia during crizotinib treatment: a retrospective analysis of two large-scale multinational trials (PROFILE 1005 and 1007).

    PubMed

    Ou, Sai-Hong Ignatius; Tang, Yiyun; Polli, Anna; Wilner, Keith D; Schnell, Patrick

    2016-04-01

    Decreases in heart rate (HR) have been described in patients receiving crizotinib. We performed a large retrospective analysis of HR changes during crizotinib therapy. HRs from vital-sign data for patients with anaplastic lymphoma kinase (ALK)-positive nonsmall cell lung cancer enrolled in PROFILE 1005 and the crizotinib arm of PROFILE 1007 were analyzed. Sinus bradycardia (SB) was defined as HR <60 beats per minute (bpm). Magnitude and timing of HR changes were assessed. Potential risk factors for SB were investigated by logistic regression analysis. Progression-free survival (PFS) was evaluated according to HR decrease by <20 versus ≥ 20 bpm within the first 50 days of starting treatment. For the 1053 patients analyzed, the mean maximum postbaseline HR decrease was 25 bpm (standard deviation 15.8). Overall, 441 patients (41.9%) had at least one episode of postbaseline SB. The mean precrizotinib treatment HR was significantly lower among patients with versus without postbaseline SB (82.2 bpm vs. 92.6 bpm). The likelihood of experiencing SB was statistically significantly higher among patients with a precrizotinib treatment HR <70 bpm. PFS was comparable among patients with or without HR decrease of ≥ 20 bpm within the first 50 days of starting crizotinib. Decrease in HR is very common among patients on crizotinib. The likelihood of experiencing SB was statistically significantly higher among patients with a precrizotinib treatment HR <70 bpm. This is the first large-scale report investigating the association between treatment with a tyrosine kinase inhibitor and the development of bradycardia. HRs should be closely monitored during crizotinib treatment. © 2016 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  10. Validation of a new algorithm for the BPM-100 electronic oscillometric office blood pressure monitor.

    PubMed

    Wright, J M; Mattu, G S; Perry, T L; Gelferc, M E; Strange, K D; Zorn, A; Chen, Y

    2001-06-01

    To test the accuracy of a new algorithm for the BPM-100, an automated oscillometric blood pressure (BP) monitor, using stored data from an independently conducted validation trial comparing the BPM-100(Beta) with a mercury sphygmomanometer. Raw pulse wave and cuff pressure data were stored electronically using embedded software in the BPM-100(Beta), during the validation trial. The 391 sets of measurements were separated objectively into two subsets. A subset of 136 measurements was used to develop a new algorithm to enhance the accuracy of the device when reading higher systolic pressures. The larger subset of 255 measurements (three readings for 85 subjects) was used as test data to validate the accuracy of the new algorithm. Differences between the new algorithm BPM-100 and the reference (mean of two observers) were determined and expressed as the mean difference +/- SD, plus the percentage of measurements within 5, 10, and 15 mmHg. The mean difference between the BPM-100 and reference systolic BP was -0.16 +/- 5.13 mmHg, with 73.7% < or = 5 mmHg, 94.9% < or = 10 mmHg and 98.8% < or = 15 mmHg. The mean difference between the BPM-100 and reference diastolic BP was -1.41 +/- 4.67 mmHg, with 78.4% < or = 5 mmHg, 92.5% < or = 10 mmHg, and 99.2% < or = 15 mmHg. These data improve upon that of the BPM-100(Beta) and pass the AAMI standard, and 'A' grade BHS protocol. This study illustrates a new method for developing and testing a change in an algorithm for an oscillometric BP monitor utilizing collected and stored electronic data and demonstrates that the new algorithm meets the AAMI standard and BHS protocol.

  11. Comparison of the oscillometric blood pressure monitor (BPM-100(Beta) ) with the auscultatory mercury sphygmomanometer.

    PubMed

    Mattu, G S; Perry, T L; Wright, J M

    2001-06-01

    To compare directly the accuracy of the BPM-100(Beta) monitor (an automated oscillometric blood pressure device) with standard auscultatory mercury sphygmomanometry. The BPM-100(Beta) was connected in parallel via a T-tube to a mercury sphygmomanometer. The BPM-100(Beta) and two trained observers (blinded from each other and from the BPM-100(Beta)) measured the sitting blood pressure simultaneously. Means, standard deviations and ranges were calculated for all the demographic data: age, arm size, heart rate and blood pressure. The agreement between the BPM-100(Beta) and the mean of two observers (the reference) was determined and expressed as the mean +/- SD, as well as the percentage of differences falling within 5, 10 and 15 mmHg. Of the 92 subjects recruited, 85 (92.4%) met the inclusion criteria, and 391 sets of sitting blood pressure and heart rate measurements were available for analysis. The mean difference between the BPM-100(Beta) monitor and the reference was -0.62 +/- 6.96 mmHg for systolic blood pressure, -1.48 +/- 4.80 mmHg for diastolic blood pressure and 0.14 +/- 1.86 beats/min for heart rate. The only limitation of the device was its tendency to underestimate higher systolic blood pressures. This problem has been addressed by a minor change in the algorithm (see the companion publication, Blood Press Monit, 6, 161-165, 2001). The BPM-100(Beta) is an accurate blood pressure monitor for the office setting, meeting all requirements of the Association for the Advancement of Medical Instrumentation and achieving an 'A' grade according to the British Hypertension Society protocol.

  12. Relationship between heart rate and quiescent interval of the cardiac cycle in children using MRI.

    PubMed

    Zhang, Wei; Bogale, Saivivek; Golriz, Farahnaz; Krishnamurthy, Rajesh

    2017-11-01

    Imaging the heart in children comes with the challenge of constant cardiac motion. A prospective electrocardiography-triggered CT scan allows for scanning during a predetermined phase of the cardiac cycle with least motion. This technique requires knowing the optimal quiescent intervals of cardiac cycles in a pediatric population. To evaluate high-temporal-resolution cine MRI of the heart in children to determine the relationship of heart rate to the optimal quiescent interval within the cardiac cycle. We included a total of 225 consecutive patients ages 0-18 years who had high-temporal-resolution cine steady-state free-precession sequence performed as part of a magnetic resonance imaging (MRI) or magnetic resonance angiography study of the heart. We determined the location and duration of the quiescent interval in systole and diastole for heart rates ranging 40-178 beats per minute (bpm). We performed the Wilcoxon signed rank test to compare the duration of quiescent interval in systole and diastole for each heart rate group. The duration of the quiescent interval at heart rates <80 bpm and >90 bpm was significantly longer in diastole and systole, respectively (P<.0001 for all ranges, except for 90-99 bpm [P=.02]). For heart rates 80-89 bpm, diastolic interval was longer than systolic interval, but the difference was not statistically significant (P=.06). We created a chart depicting optimal quiescent intervals across a range of heart rates that could be applied for prospective electrocardiography-triggered CT imaging of the heart. The optimal quiescent interval at heart rates <80 bpm is in diastole and at heart rates ≥90 bpm is in systole. The period of quiescence at heart rates 80-89 bpm is uniformly short in systole and diastole.

  13. Association of Fetal Heart Rate Baseline Change and Neonatal Outcomes.

    PubMed

    Yang, Michael; Stout, Molly J; López, Julia D; Colvin, Ryan; Macones, George A; Cahill, Alison G

    2017-07-01

    Objective  The objective of this study was to describe the incidence of baseline change within normal range during labor and its prediction of neonatal outcomes. Materials and Methods  This was a prospective cohort of singleton, nonanomalous, term neonates with continuous electronic fetal monitoring and normal baseline fetal heart rate throughout the last 2 hours of labor. We determined baseline in 10-minute segments using Eunice Kennedy Shriver National Institute of Child Health and Human Development criteria. We evaluated baseline changes of ≥ 20 and ≥ 30 bpm for association with acidemia (umbilical cord arterial pH ≤ 7.10) and neonatal intensive care unit (NICU) admission. Finally, we performed a sensitivity analysis of normal neonates, excluding those with acidemia, NICU admission, or 5-minute Apgar < 4. Results  Among all neonates ( n  = 3,021), 1,267 (41.9%) had change ≥ 20 bpm; 272 (9.0%) had ≥ 30 bpm. Among normal neonates ( n  = 2,939), 1,221 (41.5%) had change ≥20 bpm. Acidemia was not associated with baseline change of any direction or magnitude. NICU admission was associated with decrease ≥ 20 bpm (adjusted odds ratio [aOR]: 2.93; 95% confidence interval [CI]: 1.19 - 7.21) or any direction ≥ 20 bpm (aOR: 4.06; 95% CI: 1.46-11.29). For decrease ≥ 20 bpm, sensitivity and specificity were 40.0 and 81.7%; for any direction ≥ 20 bpm, 75.0 and 58.3%. Conclusion  Changes of normal baseline are common in term labor and poorly predict morbidity, regardless of direction or magnitude. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  14. Characterization and predictors of first and subsequent inappropriate ICD therapy by heart rate ranges: Result of the MADIT-RIT efficacy analysis.

    PubMed

    Kutyifa, Valentina; Daubert, James P; Olshansky, Brian; Huang, David T; Zhang, Claire; Ruwald, Anne-Christine H; McNitt, Scott; Zareba, Wojciech; Moss, Arthur J; Schuger, Claudio

    2015-09-01

    Data on inappropriate implantable cardioverter-defibrillator (ICD) therapy and effects of programming by heart rate are lacking. We aimed to characterize inappropriate ICD therapy and assess the effects of novel programming by heart rate. Incidence and causes of inappropriate therapy by heart rate range (below or above 200 bpm) were assessed. Predictors of inappropriate therapy and effects of programming by heart rate were evaluated with multivariate Cox regression models. Crossovers were excluded. Inappropriate therapy occurred in 9.2% of the total patient population, with 19% of patients randomized to study arm A, 3.6% in arm B, and 4.7% in arm C. Inappropriate therapies <200 bpm were attributable to supraventricular tachycardia (SVT)/sinus tachycardia (78%) or atrial fibrillation/flutter (20%). Inappropriate therapy ≥200 bpm occurred because of SVT (47%), atrial fibrillation/flutter (41%), or electromagnetic interference (13%). Conventional ICD programming was associated with more inappropriate therapy <200 bpm than high-rate or delayed therapy, as were younger age, history of atrial arrhythmia, advanced New York Heart Association functional class, ICD versus cardiac resynchronization therapy with defibrillator, and absence of diabetes. High-rate and long-delay therapy significantly reduced the risk of inappropriate therapy in the <200 bpm range. Long delay was associated with further reduction of fast (≥200 bpm) inappropriate therapy (P = .032) and a reduction in subsequent inappropriate episodes (P = .006). In MADIT-RIT, inappropriate ICD therapy is most frequent at rates below 200 bpm and can be predicted, and effectively prevented, with high-rate cutoff programming. Long-delay therapy effectively reduces fast inappropriate therapy ≥200 bpm and subsequent events. [ http://clinicaltrials.gov/ct2/show/NCT00947310]. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  15. Enhancement of absorption and resistance of motion utilizing a multi-channel opto-electronic sensor to effectively monitor physiological signs during sport exercise

    NASA Astrophysics Data System (ADS)

    Alzahrani, Abdullah; Hu, Sijung; Azorin-Peris, Vicente; Barrett, Laura; Esliger, Dale; Hayes, Matthew; Akbare, Shafique; Achart, Jérôme; Kuoch, Sylvain

    2015-03-01

    This study presents an effective engineering approach for human vital signs monitoring as increasingly demanded by personal healthcare. The aim of this work is to study how to capture critical physiological parameters efficiently through a well-constructed electronic system and a robust multi-channel opto-electronic patch sensor (OEPS), together with a wireless communication. A unique design comprising multi-wavelength illumination sources and a rapid response photo sensor with a 3-axis accelerometer enables to recover pulsatile features, compensate motion and increase signal-to-noise ratio. An approved protocol with designated tests was implemented at Loughborough University a UK leader in sport and exercise assessment. The results of sport physiological effects were extracted from the datasets of physical movements, i.e. sitting, standing, waking, running and cycling. t-test, Bland-Altman and correlation analysis were applied to evaluate the performance of the OEPS system against Acti-Graph and Mio-Alpha.There was no difference in heart rate measured using OEPS and both Acti-Graph and Mio-Alpha (both p<0.05). Strong correlations were observed between HR measured from the OEPS and both the Acti-graph and Mio-Alpha (r = 0.96, p<0.001). Bland-Altman analysis for the Acti-Graph and OEPS found the bias 0.85 bpm, the standard deviation 9.20 bpm, and the limits of agreement (LOA) -17.18 bpm to +18.88 bpm for lower and upper limits of agreement respectively, for the Mio-Alpha and OEPS the bias is 1.63 bpm, standard deviation SD8.62 bpm, lower and upper limits of agreement, - 15.27 bpm and +18.58 bpm respectively. The OEPS demonstrates a real time, robust and remote monitoring of cardiovascular function.

  16. Timing and tracking for the Crystal Barrel detector

    NASA Astrophysics Data System (ADS)

    Beck, Reinhard; Brinkmann, Kai; Novotny, Rainer

    2017-01-01

    The aim of the project D.3 is the upgrade of several detector components used in the CBELSA/TAPS experiment at ELSA. The readout of the Crystal Barrel Calorimeter will be extended by a timing branch in order to gain trigger capability for the detector, which will allow to measure completely neutral final states in photoproduction reactions (see projects A.1 and C.5). Additionally, the readout of the inner crystals of the TAPS detector, which covers the forward opening of the Crystal Barrel Calorimeter, will be modified to be capable of high event rates due to the intensity upgrade of ELSA. Furthermore, a full-scale prototype Time Projection Chamber (TPC) has been built to be used as a new central tracker for the CBELSA/TAPS experiment at ELSA and the FOPI experiment at GSI.

  17. Space reactor fuel element testing in upgraded TREAT

    NASA Astrophysics Data System (ADS)

    Todosow, M.; Bezler, P.; Ludewig, H.; Kato, W. Y.

    The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc.; a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR); NERVA-derivative; and other concepts are discussed. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. Initial results suggest that full-scale PBR elements could be tested at an average energy deposition of approximately 60-80 MW-s/L in the current TREAT reactor. If the TREAT reactor was upgraded to include fuel elements with a higher temperature limit, average energy deposition of approximately 100 MW/L may be achievable.

  18. Space reactor fuel element testing in upgraded TREAT

    NASA Astrophysics Data System (ADS)

    Todosow, Michael; Bezler, Paul; Ludewig, Hans; Kato, Walter Y.

    1993-01-01

    The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc., is a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR), NERVA-derivative, and other concepts. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. Initial results suggests that full-scale PBR elements could be tested at an average energy deposition of ˜60-80 MW-s/L in the current TREAT reactor. If the TREAT reactor was upgraded to include fuel elements with a higher temperture limit, average energy deposition of ˜100 MW/L may be achievable.

  19. Numerical analysis of the beam position monitor pickup for the Iranian light source facility

    NASA Astrophysics Data System (ADS)

    Shafiee, M.; Feghhi, S. A. H.; Rahighi, J.

    2017-03-01

    In this paper, we describe the design of a button type Beam Position Monitor (BPM) for the low emittance storage ring of the Iranian Light Source Facility (ILSF). First, we calculate sensitivities, induced power and intrinsic resolution based on solving Laplace equation numerically by finite element method (FEM), in order to find the potential at each point of BPM's electrode surface. After the optimization of the designed BPM, trapped high order modes (HOM), wakefield and thermal loss effects are calculated. Finally, after fabrication of BPM, it is experimentally tested by using a test-stand. The results depict that the designed BPM has a linear response in the area of 2×4 mm2 inside the beam pipe and the sensitivity of 0.080 and 0.087 mm-1 in horizontal and vertical directions. Experimental results also depict that they are in a good agreement with numerical analysis.

  20. Validation of PEP-II Resonantly Excited Turn-by-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yan, Yiton T.; Cai, Yunhai; Colocho, William.

    2007-06-28

    For optics measurement and modeling of the PEP-II electron (HER) and position (LER) storage rings, we have been doing well with MIA [1] which requires analyzing turn-by-turn Beam Position Monitor (BPM) data that are resonantly excited at the horizontal, vertical, and longitudinal tunes. However, in anticipation that certain BPM buttons and even pins in the PEP-II IR region would be missing for the run starting in January 2007, we had been developing a data validation process to reduce the effect due to the reduced BPM data accuracy on PEP-II optics measurement and modeling. Besides the routine process for ranking BPMmore » noise level through data correlation among BPMs with a singular-value decomposition (SVD), we could also check BPM data symplecticity by comparing the invariant ratios. Results from PEP-II measurement will be presented.« less

  1. The Home Depot Upgrades its Corporate Building Prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-03-01

    The Home Depot partnered with the Department of Energy (DOE) to develop and implement solutions to build new, low-energy buildings that are at least 50% below Standard 90.1-2007 of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), the American National Standards Institute (ANSI), and the Illuminating Engineering Society of North America (IESNA) as part of DOE’s Commercial Building Partnerships (CBP) Program.

  2. Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

    NASA Technical Reports Server (NTRS)

    Emrich, William J., Jr.

    2014-01-01

    Over the past year the Nuclear Thermal Rocket Element Environmental Simulator (NTREES) has been undergoing a significant upgrade beyond its initial configuration. The NTREES facility is designed to perform realistic non-nuclear testing of nuclear thermal rocket (NTR) fuel elements and fuel materials. Although the NTREES facility cannot mimic the neutron and gamma environment of an operating NTR, it can simulate the thermal hydraulic environment within an NTR fuel element to provide critical information on material performance and compatibility. The first phase of the upgrade activities which was completed in 2012 in part consisted of an extensive modification to the hydrogen system to permit computer controlled operations outside the building through the use of pneumatically operated variable position valves. This setup also allows the hydrogen flow rate to be increased to over 200 g/sec and reduced the operation complexity of the system. The second stage of modifications to NTREES which has just been completed expands the capabilities of the facility significantly. In particular, the previous 50 kW induction power supply has been replaced with a 1.2 MW unit which should allow more prototypical fuel element temperatures to be reached. The water cooling system was also upgraded to so as to be capable of removing 100% of the heat generated during. This new setup required that the NTREES vessel be raised onto a platform along with most of its associated gas and vent lines. In this arrangement, the induction heater and water systems are now located underneath the platform. In this new configuration, the 1.2 MW NTREES induction heater will be capable of testing fuel elements and fuel materials in flowing hydrogen at pressures up to 1000 psi at temperatures up to and beyond 3000 K and at near-prototypic reactor channel power densities. NTREES is also capable of testing potential fuel elements with a variety of propellants, including hydrogen with additives to inhibit corrosion of certain potential NTR fuel forms. Additional diagnostic upgrades included in the present NTREES set up include the addition of a gamma ray spectrometer located near the vent filter to detect uranium fuel particles exiting the fuel element in the propellant exhaust stream to provide additional information any material loss occurring during testing. Other aspects of the upgrade included reworking NTREES to reduce the operational complexity of the system despite the increased complexity of the induction heating system. To this end, many of the controls were consolidated on fewer panels. As part of this upgrade activity, the Safety Assessment (SA) and the Standard Operating Procedures (SOPs) for NTREES were extensively rewritten. The new 1.2 MW induction heater consists of three physical units consisting of a transformer, rectifier, and inverter. This multiunit arrangement facilitated increasing the flexibility of the induction heater by more easily allowing variable frequency operation. Frequency ranges between 20 and 60 kHz can be accommodated in the new induction heater allowing more representative power distributions to be generated within the test elements.

  3. Design, prototyping, and testing of a compact superconducting double quarter wave crab cavity

    DOE PAGES

    Xiao, Binping; Alberty, Luis; Belomestnykh, Sergey; ...

    2015-04-01

    We proposed a novel design for a compact superconducting crab cavity with a double quarter wave (DQWCC) shape. After fabrication and surface treatments, this niobium proof-of-principle cavity was tested cryogenically in a vertical cryostat. The cavity is extremely compact yet has a low frequency of 400 MHz, an essential property for service in the Large Hadron Collider luminosity upgrade. The cavity’s electromagnetic properties are well suited for this demanding task. The demonstrated deflecting voltage of 4.6 MV is well above the required 3.34 MV for a crab cavity in the future High Luminosity LHC. In this paper, we present themore » design, prototyping, and results from testing the DQWCC.« less

  4. Association of heart rate at hospital discharge with mortality and hospitalizations in patients with heart failure.

    PubMed

    Habal, Marlena V; Liu, Peter P; Austin, Peter C; Ross, Heather J; Newton, Gary E; Wang, Xuesong; Tu, Jack V; Lee, Douglas S

    2014-01-01

    Heart failure (HF) is associated with a high burden of morbidity and mortality. Hospital discharge is an opportunity for identification of modifiable prognostic factors in the transition to chronic HF. We examined the association of discharge heart rate with 30-day and 1-year mortality and hospitalization outcomes in a cohort of 9097 patients with HF discharged from hospital. Discharge heart rate was categorized into predefined groups: 40 to 60 (n=1333), 61 to 70 (n=2170), 71 to 80 (n=2631), 81 to 90 (n=1700), and >90 bpm (n=1263). There was a significant increase in all-cause 30-day mortality with adjusted odds ratios of 1.59 (95% confidence interval [CI], 1.18-2.14; P=0.003) for discharge heart rates 81 to 90 bpm and 1.56 (95% CI, 1.13-2.16; P=0.007) for heart rates>90 bpm when compared with the reference group (heart rates, 61-70 bpm). Cardiovascular death risk at 30 days was also higher with adjusted odds ratio 1.59 (discharge heart rates, 81-90 bpm; 95% CI, 1.09-2.33; P=0.017) and 1.65 (discharge heart rates, >90 bpm; 95% CI, 1.09-2.48; P=0.017). One-year all-cause mortality (adjusted odds ratio, 1.41; 95% CI, 1.16-1.72; P<0.001) and cardiovascular death (adjusted odds ratio, 1.47; 95% CI, 1.12-1.92; P=0.005) were higher with discharge heart rates>90 bpm when compared with the reference group (heart rates, 40-60 bpm). Readmissions for HF (adjusted hazard ratio, 1.26; 95% CI, 1.04-1.54; P=0.021) and cardiovascular disease (adjusted hazard ratio, 1.29; 95% CI, 1.08-1.54; P=0.004) within 30 days were also higher with discharge heart rates>90 bpm. Higher discharge heart rates were associated with greater risk of all-cause and cardiovascular mortality≤1-year follow-up and an elevated risk of 30-day readmission for HF and cardiovascular disease.

  5. High-speed multishot pellet injector prototype for the Frascati Tokamak Upgrade

    NASA Astrophysics Data System (ADS)

    Frattolillo, A.; Migliori, S.; Scaramuzzi, F.; Angelone, G.; Baldarelli, M.; Capobianchi, M.; Cardoni, P.; Domma, C.; Mori, L.; Ronci, G.

    1998-07-01

    The Frascati Tokamak Upgrade (FTU) may require multiple high-speed pellet injection in order to achieve quasi-steady-state conditions. A research and development program was thus being pursued at ENEA Frascati, aimed at developing a multishot two-stage pellet injector (MPI), featuring eight "pipe gun" barrels and eight small two-stage pneumatic guns. According to FTU requirements, the final goal is to simultaneously produce up to eight D2 pellets, and then deliver them during a plasma pulse (1 s) with any time schedule, at speeds in the 1-2.5 km/s range. A prototype was constructed and tested to demonstrate the feasibility of the concept, and optimize pellet formation and firing sequences. This laboratory facility was automatically operated by means of a programmable logic controller (PLC), and had a full eight-shot capability. However, it was equipped as a first approach with only four two-stage guns. In this article we will describe in detail the guidelines of the MPI prototype design, which were strongly influenced by some external constraints. We will also report on the results of the experimental campaign, during which the feasibility of such a two-stage MPI was demonstrated. Sequences of four intact D2 pellets in the 1.2-1.6 mm size range, fired at time intervals of a few tens up to a few hundreds of ms, were routinely delivered in a laboratory experiment at injection speeds above 2.5 km/s, with good reproducibility and satisfactory aiming dispersion. Some preliminary effort to address the problem of propellant gas handling, based on an innovative approach, gave encouraging results, and work is in progress to carry out an experiment to definitely test the feasibility of this concept.

  6. Extending BPM Environments of Your Choice with Performance Related Decision Support

    NASA Astrophysics Data System (ADS)

    Fritzsche, Mathias; Picht, Michael; Gilani, Wasif; Spence, Ivor; Brown, John; Kilpatrick, Peter

    What-if Simulations have been identified as one solution for business performance related decision support. Such support is especially useful in cases where it can be automatically generated out of Business Process Management (BPM) Environments from the existing business process models and performance parameters monitored from the executed business process instances. Currently, some of the available BPM Environments offer basic-level performance prediction capabilities. However, these functionalities are normally too limited to be generally useful for performance related decision support at business process level. In this paper, an approach is presented which allows the non-intrusive integration of sophisticated tooling for what-if simulations, analytic performance prediction tools, process optimizations or a combination of such solutions into already existing BPM environments. The approach abstracts from process modelling techniques which enable automatic decision support spanning processes across numerous BPM Environments. For instance, this enables end-to-end decision support for composite processes modelled with the Business Process Modelling Notation (BPMN) on top of existing Enterprise Resource Planning (ERP) processes modelled with proprietary languages.

  7. Heart rate never lies: interventional cardiologist and Braude's quote revised

    PubMed Central

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Background Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. Objectives To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. Design This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Results Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Conclusions Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions. PMID:26835145

  8. Heart rate never lies: interventional cardiologist and Braude's quote revised.

    PubMed

    Cook, Stéphane; Stauffer, Jean-Christophe; Goy, Jean-Jacques; Graf, Denis; Puricel, Serban; Frobert, Aurélien; Muller, Olivier; Togni, Mario; Arroyo, Diego

    2016-01-01

    Interventional cardiologists may be immune to stress, allowing them to perform complex percutaneous interventions under pressure. To assess heart rate (HR) variations as a surrogate marker of stress of interventional cardiologists during percutaneous cardiac procedures and in every-day life. This is a single-centre observational study including a total of six male interventional cardiologists performing coronary interventions and pacemaker implantations. Participants were asked to record their HR with the Apple Watch Device during procedures, every-day life and control activities such as outpatient consultations, sport, marital conflicts and sexual intercourse. Average daily HR was 88±17 bpm. During work days, HR increased significantly during procedures (90±17 bpm) compared with days outside the cathlab (87±17 bpm, p=0.02). The average HR was higher during a regular week working (88±16 bpm) compared with weekends off (84±18 bpm, p=0.002). Complex cardiac procedures were associated with higher HR up to 122 bpm. Peak HR were higher during physical exertion. Of note, participants complained of hypersexuality and mania after night shifts. Work and especially percutaneous cardiac procedures increase HR independently of physical exertion suggesting that interventional cardiologists experience mental stress and emotions.

  9. Performance of the prototype LaBr3 spectrometer developed for the JET gamma-ray camera upgrade.

    PubMed

    Rigamonti, D; Muraro, A; Nocente, M; Perseo, V; Boltruczyk, G; Fernandes, A; Figueiredo, J; Giacomelli, L; Gorini, G; Gosk, M; Kiptily, V; Korolczuk, S; Mianowski, S; Murari, A; Pereira, R C; Cippo, E P; Zychor, I; Tardocchi, M

    2016-11-01

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr 3 crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution of 5.5% at E γ = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.

  10. Space reactor fuel element testing in upgraded TREAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todosow, M.; Bezler, P.; Ludewig, H.

    1993-01-14

    The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc., a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR), NERVA-derivative, and other concepts. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. initial results suggest that full-scale PBR, elements could be tested at an average energy deposition of {approximately}60--80 MW-s/L in the current TREAT reactor. Ifmore » the TREAT reactor was upgraded to include fuel elements with a higher temperature limit, average energy deposition of {approximately}100 MW/L may be achievable.« less

  11. Space reactor fuel element testing in upgraded TREAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Todosow, M.; Bezler, P.; Ludewig, H.

    1993-05-01

    The testing of candidate fuel elements at prototypic operating conditions with respect to temperature, power density, hydrogen coolant flow rate, etc., a crucial component in the development and qualification of nuclear rocket engines based on the Particle Bed Reactor (PBR), NERVA-derivative, and other concepts. Such testing may be performed at existing reactors, or at new facilities. A scoping study has been performed to assess the feasibility of testing PBR based fuel elements at the TREAT reactor. initial results suggest that full-scale PBR, elements could be tested at an average energy deposition of {approximately}60--80 MW-s/L in the current TREAT reactor. Ifmore » the TREAT reactor was upgraded to include fuel elements with a higher temperature limit, average energy deposition of {approximately}100 MW/L may be achievable.« less

  12. Exercise Training Attenuates Sympathetic Activity and Improves Morphometry of Splenic Arterioles in Spontaneously Hipertensive Rats.

    PubMed

    Lemos, Marina de Paiva; Mota, Gustavo Ribeiro da; Marocolo, Moacir; Sordi, Carla Cristina de; Chriguer, Rosângela Soares; Barbosa Neto, Octávio

    2018-03-01

    Alterations in the structure of resistance vessels contribute to elevated systemic vascular resistance in hypertension and are linked to sympathetic hyperactivity and related lesions in target organs. To assess the effects of exercise training on hemodynamic and autonomic parameters, as well as splenic arteriolar damages in male Wistar Kyoto (WKY) and Spontaneously Hypertensive Rats (SHR). Normotensive sedentary (WKYS) and trained (WKYT) rats, and hypertensive sedentary (SHRS) and trained (SHRT) rats were included in this study. After 9 weeks of experimental protocol (swimming training or sedentary control), arterial pressure (AP) and heart rate (HR) were recorded in freely moving rats. We assessed the autonomic control of the heart by sympathetic and vagal autonomic blockade. Morphometric analyses of arterioles were performed in spleen tissues. The statistical significance level was set at p < 0.05. Resting bradycardia was observed in both trained groups (WKYT: 328.0 ± 7.3 bpm; SHRT: 337.0 ± 5.2 bpm) compared with their respective sedentary groups (WKYS: 353.2 ± 8.5 bpm; SHRS: 412.1 ± 10.4 bpm; p < 0.001). Exercise training attenuated mean AP only in SHRT (125.9 ± 6.2 mmHg) vs. SHRS (182.5 ± 4.2 mmHg, p < 0.001). The WKYT showed a higher vagal effect (∆HR: 79.0 ± 2.3 bpm) compared with WKYS (∆HR: 67.4 ± 1.7 bpm; p < 0.05). Chronic exercise decreased sympathetic effects on SHRT (∆HR: -62.8 ± 2.8 bpm) in comparison with SHRS (∆HR: -99.8 ± 9.2 bpm; p = 0.005). The wall thickness of splenic arterioles in SHR was reduced by training (332.1 ± 16.0 µm2 in SHRT vs. 502.7 ± 36.3 µm2 in SHRS; p < 0.05). Exercise training attenuates sympathetic activity and AP in SHR, which may be contributing to the morphological improvement of the splenic arterioles.

  13. Failed heart rate control with oral metoprolol prior to coronary CT angiography: effect of additional intravenous metoprolol on heart rate, image quality and radiation dose.

    PubMed

    Jiménez-Juan, Laura; Nguyen, Elsie T; Wintersperger, Bernd J; Moshonov, Hadas; Crean, Andrew M; Deva, Djeven P; Paul, Narinder S; Torres, Felipe S

    2013-01-01

    The purpose of this study was to evaluate the effect of intravenous (i.v.) metoprolol after a suboptimal heart rate (HR) response to oral metoprolol (75-150 mg) on HR control, image quality (IQ) and radiation dose during coronary CTA using 320-MDCT. Fifty-three consecutive patients who failed to achieve a target HR of < 60 bpm after an oral dose of metoprolol and required supplementary i.v. metoprolol (5-20 mg) prior to coronary CTA were evaluated. Patients with HR < 60 bpm during image acquisition were defined as responders (R) and those with HR ≥ 60 bpm as non-responders (NR). Two observers assessed IQ using a 3-point scale (1-2, diagnostic and 3, non-diagnostic). Effective dose (ED) was estimated using dose-length product and a 0.014 mSV/mGy.cm conversion factor. Baseline characteristics and HR on arrival were similar in the two groups. 58% of patients didn't achieve the target HR after receiving i.v. metoprolol (NR). R had a significantly higher HR reduction after oral (mean HR 63.9 ± 4.5 bpm vs. 69.6 ± 5.6 bpm) (p < 0.005) and i.v. (mean HR 55.4 ± 3.9 bpm vs. 67.4 ± 5.3 bpm) (p < 0.005) doses of metoprolol. Studies from NR showed a significantly higher ED in comparison to R (8.0 ± 2.9 vs. 6.1 ± 2.2 mSv) (p = 0.016) and a significantly higher proportion of non-diagnostic coronary segments (9.2 vs. 2.5%) (p < 0.001). 58% of patients who do not achieve a HR of <60 bpm prior to coronary CTA with oral fail to respond to additional i.v. metoprolol and have studies with higher radiation dose and worse image quality.

  14. Bailout intravenous esmolol for heart rate control in cardiac computed tomography angiography.

    PubMed

    Aguiar Rosa, Sílvia; Ramos, Ruben; Marques, Hugo; Santos, Rosana; Leal, Cecília; Casado, Helena; Saraiva, Márcia; Figueiredo, Luísa; Cruz Ferreira, Rui

    2016-12-01

    To evaluate the efficacy and safety of a heart rate (HR) reduction protocol using intravenous esmolol as bailout for failed oral metoprolol regimens in patients undergoing coronary computed tomography angiography (CCTA) with 64-slice multidetector computed tomography (64-MDCT). Patients who underwent cardiac 64-MDCT in a single institution between 2011 and 2014 were analyzed. Those with HR above 60 beats per minute (bpm) on presentation received oral metoprolol (50-200 mg) at least one hour before CCTA. Intravenous esmolol 1-2 mg/kg was administered as a bolus whenever HR remained over 65 bpm just before imaging. The primary efficacy endpoint was HR <65 bpm during CCTA. The primary safety endpoint was symptomatic hypotension or bradycardia up to hospital discharge. During the study period CCTA was performed in 947 cases. In 86% of these, oral metoprolol was the only medication required to successfully reduce HR <60 bpm. Esmolol was used in the remaining 130 patients (14%). For esmolol-treated patients mean baseline and acquisition HR were 74±14 bpm and 63±9 bpm, respectively (p<0.001). The target HR of <65 bpm was achieved in 82 of the 130 esmolol-treated patients (63%). Considering the whole population, esmolol use led to a significant increase in the primary efficacy endpoint from 86% to 95% (p<0.001). Esmolol also resulted in a statistically, but not clinically, significant reduction in systolic blood pressure (144±22 to 115±17 mmHg; p<0.001). The combined primary safety endpoint was only observed in two (1.5%) patients. Despite optimal use of oral beta-blockers, 14% of patients needed intravenous esmolol for HR control. The pre-medication combination of oral metoprolol and on-demand administration of intravenous esmolol was safe and effective and enabled 95% of patients to be imaged with HR below 65 bpm. Copyright © 2016 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  15. Heart rate at discharge and long-term prognosis following percutaneous coronary intervention in stable and acute coronary syndromes--results from the BASKET PROVE trial.

    PubMed

    Jensen, Magnus Thorsten; Kaiser, Christoph; Sandsten, Karl Erik; Alber, Hannes; Wanitschek, Maria; Iversen, Allan; Jensen, Jan Skov; Pedersen, Sune; Soerensen, Rikke; Rickli, Hans; Zurek, Marzena; Fahrni, Gregor; Bertel, Osmund; De Servi, Stefano; Erne, Paul; Pfisterer, Matthias; Galatius, Søren

    2013-10-09

    Elevated heart rate (HR) is associated with mortality in a number of heart diseases. We examined the long-term prognostic significance of HR at discharge in a contemporary population of patients with stable angina (SAP), non-ST-segment elevation acute coronary syndromes (NSTE-ACS), and ST-segment elevation myocardial infarction (STEMI) revascularized with percutaneous coronary intervention (PCI). Patients from the BASKET-PROVE trial, an 11-center randomized all-comers trial comparing bare-metal and drug-eluting stenting in large coronary vessels, were included. Discharge HR was determined from a resting ECG. Long-term outcomes (7 days to 2 years) were evaluated for all-cause mortality and cardiovascular death and non-fatal myocardial infarction. A total of 2029 patients with sinus rhythm were included, 722 (35.6%) SAP, 647 (31.9%) NSTE-ACS, and 660 (32.5%) STEMI. Elevated discharge HR was associated significantly with all-cause mortality: when compared to a reference of <60 beats per minute (bpm), the adjusted hazard ratios were (95% CI) 4.5 (1.5-13.5, p=0.006) for 60-69 bpm, 3.8 (1.2-11.9, p=0.022) for 70-79 bpm, 4.3 (1.2-15.6, p=0.025) for 80-89 bpm, and 16.9 (5.2-55.0, p<0.001) for >90 bpm. For cardiovascular death/myocardial infarction, a discharge HR >90 bpm was associated with a hazard ratio of 6.2 (2.5-15.5, p<0.001) compared to a HR <60 bpm. No interaction was found for disease presentation, diabetes or betablocker use. In patients revascularized with PCI for stable angina or acute coronary syndromes an elevated discharge HR was independently associated with poor prognosis. Conversely, a HR <60 bpm at discharge was associated with a good long-term prognosis irrespective of indication for PCI. © 2013.

  16. Utility of Time and Frequency Domain Parameters of Heart Rate Variability in the Context of Autonomic Disorders Characterized by Orthostatic Dysfunction.

    PubMed

    Baker, Jacquie; Racosta, Juan M; Balint, Brittany; Kimpinski, Kurt

    2018-03-01

    The clinical significance of heart rate variability in the context of autonomic dysfunction continues to be a matter of debate. A consensus is lacking on the best heart rate variability measures for clinical purposes. Therefore, the purpose of this study was to investigate the utility of heart rate variability parameters in healthy versus autonomic dysfunction. Healthy young (n = 134), healthy older (n = 32), and patients with mild (postural tachycardia syndrome; n = 25) and severe (neurogenic orthostatic hypotension; n = 34) autonomic dysfunction were included. Time and frequency parameters during baseline, head-up tilt (HUT), and heart rate response to deep breathing (HRDB) were compared. Cardiovagal time parameters were significantly reduced during HUT in healthy young and postural tachycardia syndrome (P < 0.001). Healthy young had significantly higher time parameters during baseline, HUT, and HRDB (P < 0.01). This was reflected by a significantly lower resting heart rate (HR) (61.4 ± 9.0 bpm vs. 76.8 ± 13.6 bpm; P < 0.001) and a smaller [INCREMENT]HR during HUT (32.8 ± 10.5 bpm vs. 44.4 ± 13.3 bpm; P < 0.001). Time parameters increased in young and postural tachycardia syndrome during HRDB, which was characterized by a nonsignificant difference in [INCREMENT]HR between both groups. Time parameters were significantly higher in healthy old versus neurogenic orthostatic hypotension at rest and during HRDB (P < 0.05). During HUT, only the SD of all normal RR intervals remained significantly higher. Heart rate changes corroborated these findings. Resting HR was significantly lower in healthy older (62.6 ± 11.0 bpm vs. 70.7 ± 12.4 bpm), and [INCREMENT]HR during HRDB was significantly higher (15.9 ± 9.2 bpm vs. 3.9 ± 4.2 bpm; P < 0.001). During HUT, [INCREMENT]HR showed no significant differences. Time domain parameters of heart rate variability have a greater utility than frequency parameters in clinical autonomic disorders.

  17. Central antioxidant therapy inhibits parasympathetic baroreflex control in conscious rats.

    PubMed

    Giusti, Marcelo Franchini; Sato, Monica Akemi; Cardoso, Leonardo Máximo; Braga, Valdir Andrade; Colombari, Eduardo

    2011-02-04

    Baroreceptor reflex is an important system for neural control of blood pressure. Recently, reactive oxygen species (ROS) have been shown to play an important role in neuronal activity of central areas related to blood pressure control. The aim of this study was to investigate the effects elicited by ascorbic acid (AAC) and N-acetylcysteine (NAC) injections into the 4thV on the parasympathetic component of the baroreflex. Male Wistar rats were implanted with a stainless steel guide cannula into the 4thV. One day prior to the experiments, the femoral artery and vein were cannulated for pulsatile arterial pressure, mean arterial pressure and heart rate measurements and drug administration, respectively. After baseline recordings, the baroreflex was tested with a pressor dose of phenylephrine (PHE, 3 μg/kg, i.v.) and a depressor dose of sodium nitroprusside (SNP, 30 μg/kg, i.v.) before (control) and 5, 15, 30 and 60 min after AAC or NAC into the 4thV. Control PHE injection induced baroreflex-mediated bradycardia (-93 ± 13 bpm, n=7). Interestingly, after AAC injection into the 4thV, PHE injection produced a transient tachycardia at 5 (40 ± 23 bpm), 15 (26 ± 22 bpm) and 30 min (59 ± 21 bpm). No changes were observed in baroreflex-mediated tachycardia evoked by SNP after AAC injection on 4thV (control: 151 ± 23bpm vs. 135 ± 18 bpm at 5 min after AAC, n=7). In the NAC treated group, PHE induced a reduction in reflex bradycardia at 5 min when compared to control (-11 ± 17 bpm vs. -83 ± 15 bpm, n=7). No changes were observed in baroreflex-mediated tachycardia evoked by SNP after NAC injection on 4thV. The antioxidants AAC and NAC may act in the central nervous system affecting the parasympathetic component of the cardiac baroreflex. Copyright © 2010 Elsevier Ireland Ltd. All rights reserved.

  18. A high-efficiency fibre double-scrambler prototype

    NASA Astrophysics Data System (ADS)

    Barnes, Stuart I.; MacQueen, Phillip J.

    2010-07-01

    Results for a high efficiency fibre double-scrambler are reported. The scrambler is based on the concept first presented by Casse and Vieira (1997) but with a substantial improvement in performance. The design uses a simple finite conjugate relay with large magnification followed by a combined scrambler/focal reducer singlet. This approach allows flexibility in the coupling of fibres with various focal ratios and diameters, and can be used to minimize loss of throughput due to focal ratio degradation. A prototype has been constructed using simple off-the-shelf optics which is shown to be capable of coupling a 15m long 300 μm fibre to a 5m long 320 μm fibre with an absolute efficiency of 75%. The focal ratio degradation (FRD) of the prototype is 7% when operated at f/3.65. A fully optimized version with both improved efficiency (>85%) and FRD is intended to be deployed as part of the Hobby Eberly Telescope HRS upgrade.

  19. Initial Operation and Shakedown of the Nuclear Thermal Rocket Element Environmental Simulator (NTREES)

    NASA Technical Reports Server (NTRS)

    Emrich, William J., Jr.

    2014-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Prototypical fuel elements mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission in addition to being exposed to flowing hydrogen. Recent upgrades to NTREES now allow power levels 24 times greater than those achievable in the previous facility configuration. This higher power operation will allow near prototypical power densities and flows to finally be achieved in most prototypical fuel elements.

  20. Association of Asymptomatic Bradycardia With Incident Cardiovascular Disease and Mortality: The Multi-Ethnic Study of Atherosclerosis (MESA).

    PubMed

    Dharod, Ajay; Soliman, Elsayed Z; Dawood, Farah; Chen, Haiying; Shea, Steven; Nazarian, Saman; Bertoni, Alain G

    2016-02-01

    Bradycardia has been associated with lower cardiovascular disease (CVD) risk in selected populations. There is a paucity of information available about heart rate (HR) less than 50 beats per minute (bpm) among middle-aged or older adults. To determine whether asymptomatic bradycardia was associated with a lower cardiovascular risk profile, less subclinical atherosclerosis, and decreased incident CVD and mortality. This retrospective analysis includes 6733 participants of the Multi-Ethnic Study of Atherosclerosis, which recruited men and women free of clinical cardiovascular disease ages 45 to 84 years from 2000 to 2002 and followed them over 10 years for incident CVD events and mortality. The HR was measured by baseline electrocardiogram. The analysis was performed in June 2014. The association between HR categories with CVD events and all-cause mortality were examined using Cox proportional hazards models adjusted for potential confounders and mediators. The 6733 participants had a mean (SD) age of 62 (10.2) years; 47% were male. The mean (SD) HR was 63 (9.5) bpm among the 5831 participants not taking an HR-modifying drug; 5.3% had an HR lower than 50 bpm. Preliminary results revealed significant interaction for HR categories according to use of HR-modifying drugs for mortality (P = .002); thus, all further analyses were stratified. An HR of less than 50 bpm was not associated with incident CVD in either subgroup (participants taking or not taking HR-modifying drugs). Among participants not taking HR-modifying drugs, the fully adjusted mortality risk was not different for an HR less than 50 bpm (hazard ratio, 0.71 [95% CI, 0.41-1.09]; P = .12) and increased among those with an HR greater than 80 bpm (hazard ratio, 1.49 [95% CI, 1.08-2.05]; P = .01) (reference HR, 60-69 bpm). Among the 902 participants taking HR-modifying drugs there was an elevated mortality risk associated with an HR less than 50 bpm (hazard ratio, 2.42 [95% CI, 1.39-4.20]; P = .002) and with an HR greater than 80 bpm (hazard ratio, 3.55 [95% CI, 1.65-7.65]; P = .001) (reference HR, 60-69 bpm). In a contemporary, community-based cohort, bradycardia was generally not associated with incident CVD or mortality except for a potential adverse association between bradycardia among those taking HR-modifying drugs.

  1. BPM Breakdown Potential in the PEP-II B-factory Storage Ring Collider

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weathersby, Stephen; Novokhatski, Alexander; /SLAC

    2010-02-10

    High current B-Factory BPM designs incorporate a button type electrode which introduces a small gap between the button and the beam chamber. For achievable currents and bunch lengths, simulations indicate that electric potentials can be induced in this gap which are comparable to the breakdown voltage. This study characterizes beam induced voltages in the existing PEP-II storage ring collider BPM as a function of bunch length and beam current.

  2. Noise estimation of beam position monitors at RHIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shen, X.; Bai, M.; Lee, S. Y.

    2014-02-10

    Beam position monitors (BPM) are used to record the average orbits and transverse turn-by-turn displacements of the beam centroid motion. The Relativistic Hadron Ion Collider (RHIC) has 160 BPMs for each plane in each of the Blue and Yellow rings: 72 dual-plane BPMs in the insertion regions (IR) and 176 single-plane modules in the arcs. Each BPM is able to acquire 1024 or 4096 consecutive turn-by-turn beam positions. Inevitably, there are broadband noisy signals in the turn-by-turn data due to BPM electronics as well as other sources. A detailed study of the BPM noise performance is critical for reliable opticsmore » measurement and beam dynamics analysis based on turn-by-turn data.« less

  3. Cavity BPM system tests for the ILC energy spectrometer

    NASA Astrophysics Data System (ADS)

    Slater, M.; Adolphsen, C.; Arnold, R.; Boogert, S.; Boorman, G.; Gournaris, F.; Hildreth, M.; Hlaing, C.; Jackson, F.; Khainovski, O.; Kolomensky, Yu. G.; Lyapin, A.; Maiheu, B.; McCormick, D.; Miller, D. J.; Orimoto, T. J.; Szalata, Z.; Thomson, M.; Ward, D.; Wing, M.; Woods, M.

    2008-07-01

    The main physics programme of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10-4 or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 h for a 1 m long BPM triplet. We find micron-level stability over 1 h for 3 BPM stations distributed over a 30 m long baseline. The understanding of the behaviour and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.

  4. Statistical analysis of RHIC beam position monitors performance

    NASA Astrophysics Data System (ADS)

    Calaga, R.; Tomás, R.

    2004-04-01

    A detailed statistical analysis of beam position monitors (BPM) performance at RHIC is a critical factor in improving regular operations and future runs. Robust identification of malfunctioning BPMs plays an important role in any orbit or turn-by-turn analysis. Singular value decomposition and Fourier transform methods, which have evolved as powerful numerical techniques in signal processing, will aid in such identification from BPM data. This is the first attempt at RHIC to use a large set of data to statistically enhance the capability of these two techniques and determine BPM performance. A comparison from run 2003 data shows striking agreement between the two methods and hence can be used to improve BPM functioning at RHIC and possibly other accelerators.

  5. A data acquisition system for marine and ecological research.

    NASA Technical Reports Server (NTRS)

    Johnson, R. A.

    1971-01-01

    Description of a self-contained portable data acquisition system for use in marine and ecological research. The compact lightweight data acquisition system is capable of recording 14 variables in its present configuration and is suitable for use in either a boat, pickup truck, or light aircraft. This system will provide the acquisition of reliable data on the structure of the environment and the effect of man-made and natural activities on the observed phenomenon. Utilizing both self-contained analog recording and a telemetry transmitter for real-time digital readout and recording, the prototype system has undergone extensive testing. Currently undergoing component performance upgrading, the prototype system has been utilized in several environmental science investigations associated with air pollution investigations and weather modification and is currently being used for marine data acquisition.

  6. Optimal reconstruction interval in dual source CT coronary angiography: a single-center experience in 285 patients

    PubMed Central

    Akgöz, Ayça; Akata, Deniz; Hazırolan, Tuncay; Karçaaltıncaba, Muşturay

    2014-01-01

    PURPOSE We aimed to evaluate the visibility of coronary arteries and bypass-grafts in patients who underwent dual source computed tomography (DSCT) angiography without heart rate (HR) control and to determine optimal intervals for image reconstruction. MATERIALS AND METHODS A total of 285 consecutive cases who underwent coronary (n=255) and bypass-graft (n=30) DSCT angiography at our institution were identified retrospectively. Patients with atrial fibrillation were excluded. Ten datasets in 10% increments were reconstructed in all patients. On each dataset, the visibility of coronary arteries was evaluated using the 15-segment American Heart Association classification by two radiologists in consensus. RESULTS Mean HR was 76±16.3 bpm, (range, 46–127 bpm). All coronary segments could be visualized in 277 patients (97.19%). On a segment-basis, 4265 of 4275 (99.77%) coronary artery segments were visible. All segments of 56 bypass-grafts in 30 patients were visible (100%). Total mean segment visibility scores of all coronary arteries were highest at 70%, 40%, and 30% intervals for all HRs. The optimal reconstruction intervals to visualize the segments of all three coronary arteries in descending order were 70%, 60%, 80%, and 30% intervals in patients with a mean HR <70 bpm; 40%, 70%, and 30% intervals in patients with a mean HR 70–100 bpm; and 40%, 50%, and 30% in patients with a mean HR >100 bpm. CONCLUSION Without beta-blocker administration, DSCT coronary angiography offers excellent visibility of vascular segments using both end-systolic and mid-late diastolic reconstructions at HRs up to 100 bpm, and only end-systolic reconstructions at HRs over 100 bpm. PMID:24834490

  7. Prognostic impact of heart rate in elderly with systolic heart failure and concomitant atrial fibrillation.

    PubMed

    Barywani, Salim; Petzold, Max

    2017-08-01

    The present study aimed to investigate the impact of resting heart rate (HR) on 5-year all-cause mortality in patients ≥80 years with heart failure (HF) with reduced ejection fraction (HFrEF) and concomitant atrial fibrillation (AF) after optimal up-titration of beta-blockers (BBs). Patients (n = 185) aged ≥80 years with HF and left ventricular ejection fraction ≤40% were included between January 2000 and January 2008 from two university hospitals, Sahlgrenska and Östra and retrospectively studied from January 2 to May 30, 2013. Up-titrations of guideline recommended medications were performed at HF outpatient clinics. Of whole study population, 54% (n= 100) had AF. After optimal up-titration of BBs and angiotensin converting enzyme inhibitors (ACEIs)/angiotensin receptor blockers (ARBs), mean HR in patients with AF was 73 ± 15 beats/minute (bpm), 36% had resting HR ≤65 bpm. Five-year all-cause mortality among patients with AF was significantly lower in patients with HR ≤65 bpm (63%) compared to HR >65 (80%). Cox proportional-hazard regression analysis adjusted for clinically important baseline variables and doses of ACEIs/ARBs and BBs demonstrated resting HR ≤65 bpm as an independent predictor of improved survival compared to resting HR >65 bpm (HR 0.3, 95%CI 0.1-0.7, P 0.005). In octogenarians with HFrEF and concomitant AF, lowering resting HR to levels as low as HR ≤65 bpm was still associated with improved survival from all-cause mortality. Our data indicate that mortality in AF became comparable to SR when patients were on maximally up-titrated beta-blocker doses with HR as low as 75 bpm.

  8. Surgical management of bronchopulmonary malformations.

    PubMed

    Wagenaar, Amy E; Tashiro, Jun; Hirzel, Alicia; Rodriguez, Luis I; Perez, Eduardo A; Hogan, Anthony R; Neville, Holly L; Sola, Juan E

    2015-10-01

    Bronchopulmonary malformations (BPM) are rare conditions, which typically arise below the carina and can result in significant morbidity (infection and/or hemorrhage) and mortality (respiratory failure). All children with BPM surgically treated from 2001-2014 at a tertiary care children's hospital were identified. Patient demographics, surgical indications, procedure type, estimated blood loss, pathology, perioperative complications, length of stay, and outcomes were analyzed. A total of 41 BPM patients underwent surgery with 98% overall survival (one abdominal BPM expired) but 100% for thoracic lesions. Resections were performed thoracoscopically (37%), thoracoscopy converted to open (22%), and via thoracotomy (37%). Poor visualization (67%) or inability to tolerate single lung ventilation (33%) led to conversions. No conversions resulted from hemorrhage or received blood transfusions. Patients with prenatally diagnosed BPM were more likely to undergo thoracoscopic surgery (odds ratio [OR], 18.2) versus nonprenatally diagnosed, P = 0.002. Open/converted patients had longer chest tube days (6.2) versus thoracoscopic (2.9), P = 0.048. Additionally, respiratory distress was a more common indication in patients aged <4 mo (OR, 28.0) versus ≥4 mo and <6 kg (OR, 40.5) versus ≥6 kg, P < 0.001. Open resections were more common in patients aged <4 mo (OR, 26.3) versus ≥4 mo, P = 0.002. Operative time was shorter and estimated blood loss (mL/kg) was greater for <6 versus ≥6 kg, P < 0.05. BPM resections have high overall survival. Chest tube days are shorter among thoracoscopic patients, but conversion to thoracotomy can avoid hemorrhage and need for transfusion. Size and respiratory distress limit use of thoracoscopy in young infants with BPM. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Dependency of exercise-induced T-wave alternans predictive power for the occurrence of ventricular arrhythmias from heart rate.

    PubMed

    Burattini, Laura; Man, Sumche; Fioretti, Sandro; Di Nardo, Francesco; Swenne, Cees A

    2015-07-01

    T-wave alternans (TWA) is a noninvasive index of risk for the occurrence of ventricular arrhythmias. It is known that TWA amplitude (TWAA) increases with heart rate (HR) but how the TWA predictive power varies with HR remains unknown. Thus, the aim of this study was to evaluate the dependency of exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias from HR. TWA was identified using our HR adaptive match filter in exercise ECGs from 248 patients with implanted cardiac defibrillator (ICD), of which 72 developed ventricular tachycardia and/or fibrillation during the 4 year follow-up (ICD_Cases) and 176 did not (ICD_Controls). TWA predictive power was evaluated at HRs from 80 to 120 bpm by computing the area under the receiver operating characteristic curve (AUC) obtained using the maximum TWAA (maxTWAA) and the TWAA ratio (TWAAratio; i.e., the ratio between TWAA at a specific HR and at 80 bpm). TWAA increased with HR. At 80 bpm maxTWAA was lower than at 120 bpm in both ICD_Cases (22 μV vs 41 μV; P < 10(-2) ) and ICD_ Controls (16 μV vs 36 μV; P < 10(-4) ). However, only at 80 bpm ICD_Cases showed significantly higher maxTWAA than ICD_Controls (AUC = 0.6486; P = 0.0080). TWAAratio was higher in ICD_Controls than ICD_Cases for all HR but 120 bpm, and its predictive power was maximum at 115 bpm (AUC = 0.6914; P < 0.05). Exercise-induced TWA predictive power for the occurrence of ventricular arrhythmias, quantified using both maxTWAA and TWAAratio, was higher at low rather than at high HR. © 2014 Wiley Periodicals, Inc.

  10. Reliability and Validity the Brief Problem Monitor, an Abbreviated Form of the Child Behavior Checklist

    PubMed Central

    Piper, Brian J.; Gray, Hilary M.; Raber, Jacob; Birkett, Melissa A.

    2014-01-01

    Aim The parent form of the 113 item Child Behavior Checklist (CBCL) is widely utilized by child psychiatrists and psychologists. This report examines the reliability and validity of a recently developed abbreviated version of the CBCL, the Brief Problem Monitor (BPM). Methods Caregivers (N=567) completed the CBCL online and the 19 BPM items were examined separately. Results Internal consistency of the BPM was high (Cronbach’s alpha=0.91) and satisfactory for the Internalizing (0.78), Externalizing (0.86), and Attention (0.87) scales. High correlations between the CBCL and BPM were identified for the total score (r=0.95) as well as the Internalizing (0.86), Externalizing (0.93), and Attention (0.97) scales. The BPM and scales were sensitive and identified significantly higher behavioral and emotional problems among children whose caregiver reported a psychiatric diagnosis of Attention Deficit Hyperactivity Disorder, bipolar, depression, anxiety, developmental disabilities, or Autism Spectrum Disorders relative to a comparison group that had not been diagnosed with these disorders. BPM ratings also differed by the socioeconomic status and education of the caregiver. Mothers with higher annual incomes rated their children as having 38.8% fewer total problems (Cohen’s d=0.62) as well as 42.8% lower Internalizing (d=0.53), 44.1% less Externalizing (d=0.62), and 30.9% decreased Attention (d=0.39). A similar pattern was evident for maternal education (d=0.30 to 0.65). Conclusion Overall, these findings provide strong psychometric support for the BPM although the differences based on the characteristics of the parent indicates that additional information from other sources (e.g., teachers) should be obtained to complement parental reports. PMID:24735087

  11. Heart rate in patients with reduced ejection fraction: relationship between single time point measurement and mean heart rate on prolonged implantable cardioverter defibrillator monitoring.

    PubMed

    Habal, Marlena V; Nanthakumar, Kumaraswamy; Austin, Peter C; Freitas, Cassandra; Labos, Christopher; Lee, Douglas S

    2018-01-31

    Heart rate (HR) is a prognostic marker that is increasingly used as a therapeutic target in patients with cardiovascular disease. The association between resting and mean HR remains unclear. We therefore set out to determine the relationship between resting HR on the electrocardiogram (ECG) obtained at a single time point, and mean HR on implantable cardioverter defibrillator (ICD) interrogation amongst patients with a reduced left ventricular ejection fraction (LVEF). Prospective ICD data were obtained from 54 patients with LVEF < 40%. Mean HR determined using the ICD HR histograms was compared with resting HR measured on the ECG performed in the clinic. Average resting and ICD mean HRs were 67.9 ± 10.1 and 67.8 ± 9.6 bpm respectively. There was good correlation in the overall cohort (r = 0.79), in those with resting ECG HRs ≤ 70 bpm (r = 0.62), and amongst the 27 patients on intermediate-to-high dose beta-blockers (r = 0.91). However, Bland-Altman analysis demonstrated wide limits of agreement in the overall cohort (- 12.5, 12.7 bpm), at resting HRs ≤ 70 bpm (- 12.7, 9.8 bpm), and on intermediate-to-high dose beta-blockers (- 8.9, 7.4 bpm). Moreover, resting HR did not predict the 10-bpm interval where the most time was spent. While resting HR correlated with mean HR in patients with reduced LVEF, and in important subgroups, the limits of agreement were unacceptably wide raising concern over the use of single time point resting HR as a therapeutic target.

  12. Comparing the Effects of Rest and Massage on Return to Homeostasis Following Submaximal Aerobic Exercise: a Case Study.

    PubMed

    Resnick, Portia B

    2016-03-01

    Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject's heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session.

  13. Renal sympathetic denervation improves rate control in patients with symptomatic persistent atrial fibrillation and hypertension.

    PubMed

    Qiu, Min; Shan, Qijun; Chen, Chun; Geng, Jie; Guo, Jiqun; Zhou, Xiujuan; Qian, Weichong; Tang, Lijun; Yin, Yuehui

    2016-02-01

    The aim of this study was to investigate whether renal sympathetic denervation (RSD) improves ventricular heart rate (HR) control in patients with persistent atrial fibrillation (AF). Twenty-one patients (aged 57.5 ± 10.2 years, 76.2% male) with persistent AF and hypertension underwent RSD and completed 7-days follow-up evaluations, including 24-hour Holter monitoring (Holter), blood pressure (BP), 24-hour ambulatory BP monitoring (ABPM). Patients were grouped into tertiles of average HR at baseline Holter recording for evaluation of RSD effects on atrioventricular (AV) node (group 1: HR ≧ 90 bpm; group 2: 80 bpm ≦ HR < 90 bpm; group 3: HR < 80 bpm). All patients successfully underwent RSD without any complications. The clinical and procedural characteristics were similar in all groups of patients. No significant changes in BP were observed in the three groups before and after RSD. Compared with baseline, the average HR (Holter) of patients in group 1, 2 and 3 had a reduction of 22.6 ± 13.2 bpm (83.3 ± 4.9 vs 106.0 ± 14.6, P = 0.004), 9.7 ± 7.8 bpm (75.7 ± 7.6 vs 85.4 ± 3.7, P = 0.017) and 2.3 ± 2.9 bpm (71.4 ± 4.0 vs 73.7 ± 4.7, P = 0.089) at 7 days after RSD, respectively. RSD could improve ventricular HR control in patients with persistent AF. RSD slowed AV node conduction in baseline HR-dependent manner. RSD may become an alternative non-pharmaceutical tool for rate control in patients with persistent AF.

  14. Behavioral correlates of heart rates of free-living Greater White-fronted Geese

    USGS Publications Warehouse

    Ely, Craig R.; Ward, D.H.; Bollinger, K.S.

    1999-01-01

    We simultaneously monitored the heart rate and behavior of nine free-living Greater White-fronted Geese (Anser albifrons) on their wintering grounds in northern California. Heart rates of wild geese were monitored via abdominally-implanted radio transmitters with electrodes that received electrical impulses of the heart and emitted a radio signal with each ventricular contraction. Post-operative birds appeared to behave normally, readily rejoining flocks and flying up to 15 km daily from night-time roost sites to feed in surrounding agricultural fields. Heart rates varied significantly among individuals and among behaviors, and ranged from less than 100 beats per minute (BPM) during resting, to over 400 BPM during flight. Heart rates varied from 80 to 140 BPM during non-strenuous activities such as walking, feeding, and maintenance activities, to about 180 BPM when birds became alert, and over 400 BPM when birds were startled, even if they did not take flight. Postflight heart rate recovery time averaged < 10 sec. During agonistic encounters, heart rate exceeded 400 BPM; heart rates during social interactions were not predictable solely from postures, as heart rates were context-dependent, and were highest in initial encounters among individuals. Instantaneous measures of physiological parameters, such as heart rate, are often better indicators of the degree of response to external stimuli than visual observations and can be used to improve estimates of energy expenditure based solely on activity data.

  15. Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

    NASA Astrophysics Data System (ADS)

    Xu, Wei; Li, Jing-Yi; Huang, Sen-Lin; Z. Wu, W.; Hao, H.; P., Wang; K. Wu, Y.

    2014-10-01

    The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). It is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and γ-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide range of single-bunch current. Simulations and electron beam based tests are performed. The results show that the Duke storage ring BPM system is capable of providing precise orbit measurements to ensure highly stable FEL and HIGS operations.

  16. Micro Autonomous Systems and Technology: A Methodology for Quantitative Technology Assessment and Prototyping of Unmanned Vehicles

    DTIC Science & Technology

    2012-01-30

    Sensors: LIDAR , Camera, SONAR) is qualitatively or quantitatively ranked against the other options in such categories as weight and power consumption...Mapping ( SLAM ) and A*. The second software change in progress is upgrading from Unreal 2004 to is a bridge between an external program that defines a...current simulation setup, a simulated quad-copter with an Inertial Navigation System (INS) and ranging LIDAR sensor spawns within an environment and

  17. A full vectorial generalized discontinuous Galerkin beam propagation method (GDG-BPM) for nonsmooth electromagnetic fields in waveguides

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fan Kai; Cai Wei; Ji Xia

    2008-07-20

    In this paper, we propose a new full vectorial generalized discontinuous Galerkin beam propagation method (GDG-BPM) to accurately handle the discontinuities in electromagnetic fields associated with wave propagations in inhomogeneous optical waveguides. The numerical method is a combination of the traditional beam propagation method (BPM) with a newly developed generalized discontinuous Galerkin (GDG) method [K. Fan, W. Cai, X. Ji, A generalized discontinuous Galerkin method (GDG) for Schroedinger equations with nonsmooth solutions, J. Comput. Phys. 227 (2008) 2387-2410]. The GDG method is based on a reformulation, using distributional variables to account for solution jumps across material interfaces, of Schroedinger equationsmore » resulting from paraxial approximations of vector Helmholtz equations. Four versions of the GDG-BPM are obtained for either the electric or magnetic field components. Modeling of wave propagations in various optical fibers using the full vectorial GDG-BPM is included. Numerical results validate the high order accuracy and the flexibility of the method for various types of interface jump conditions.« less

  18. Detection of Instrumental Drifts in the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wittmer, W.; Fisher, A.S.; Martin, D.J.

    2007-11-07

    During the last PEP-II run a major goal was to bring the Low-Energy Ring optics as close as possible to the design. A large number of BPMs exhibited sudden artificial jumps that interfered with this effort. The source of the majority of these jumps had been traced to the filter-isolator boxes (FIBs) near the BPM buttons. A systematic approach to find and repair the failing units had been developed and implemented. Despite this effort, the instrumental orbit jumps never completely disappeared. To trace the source of this behavior a test setup, using a spare Bergoz MX-BPM processor (kindly provided bymore » SPEAR III at SSRL), was connected in parallel to various PEP-II BPM processors. In the course of these measurements a slow instrumental orbit drift was found which was clearly not induced by a moving positron beam. Based on the size of the system and the limited time before PEP-II closes in Oct.2008, an accelerator improvement project was initiated to install BERGOZ BPM-MX processors close to all sextupoles.« less

  19. A Reverse-Translational Approach to Bipolar Disorder: Rodent and human studies in the Behavioral Pattern Monitor

    PubMed Central

    Young, Jared W.; Minassian, Arpi; Paulus, Martin P.; Geyer, Mark A.; Perry, William

    2007-01-01

    Mania is the defining feature of Bipolar Disorder (BD). There has been limited progress in understanding the neurobiological underpinnings of BD mania and developing novel therapeutics, in part due to a paucity of relevant animal models with translational potential. Hyperactivity is a cardinal symptom of mania, traditionally measured in humans using observer-rated scales. Multivariate assessment of unconditioned locomotor behavior using the rat Behavioral Pattern Monitor (BPM) developed in our laboratory has shown that hyperactivity includes complex multifaceted behaviors. The BPM has been used to demonstrate differential effects of drugs on locomotor activity and exploratory behavior in rats. Studies of genetically engineered mice in a mouse BPM have confirmed its utility as a cross-species tool. In a “reverse-translational” approach to this work, we developed the human BPM to characterize motor activity in BD patients. Increased activity, object interactions, and altered locomotor patterns provide multidimensional phenotypes to model in the rodent BPM. This unique approach to modeling BD provides an opportunity to identify the neurobiology underlying BD mania and test novel antimanic agents. PMID:17706782

  20. Cavity BPM System Tests for the ILC Spectrometer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slater, M.

    2007-12-21

    The main physics program of the International Linear Collider (ILC) requires a measurement of the beam energy at the interaction point with an accuracy of 10{sup -4} or better. To achieve this goal a magnetic spectrometer using high resolution beam position monitors (BPMs) has been proposed. This paper reports on the cavity BPM system that was deployed to test this proposal. We demonstrate sub-micron resolution and micron level stability over 20 hours for a 1 m long BPM triplet. We find micron-level stability over 1 hour for 3 BPM stations distributed over a 30 m long baseline. The understanding ofmore » the behavior and response of the BPMs gained from this work has allowed full spectrometer tests to be carried out.« less

  1. RHIC BPM SYSTEM MODIFICATIONS AND PERFORMANCE.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    SATOGATA, T.; CALAGA, R.; CAMERON, P.

    2005-05-16

    The RHIC beam position monitor (BPM) system provides independent average orbit and turn-by-turn (TBT) position measurements. In each ring, there are 162 measurement locations per plane (horizontal and vertical) for a total of 648 BPM planes in the RHIC machine. During 2003 and 2004 shutdowns, BPM processing electronics were moved from the RHIC tunnel to controls alcoves to reduce radiation impact, and the analog signal paths of several dozen modules were modified to eliminate gain-switching relays and improve signal stability. This paper presents results of improved system performance, including stability for interaction region beam-based alignment efforts. We also summarize performancemore » of recently-added DSP profile scan capability, and improved million-turn TBT acquisition channels for 10 Hz triplet vibration, nonlinear dynamics, and echo studies.« less

  2. Service Contract Compliance Management in Business Process Management

    NASA Astrophysics Data System (ADS)

    El Kharbili, Marwane; Pulvermueller, Elke

    Compliance management is a critical concern for corporations, required to respect contracts. This concern is particularly relevant in the context of business process management (BPM) as this paradigm is getting adopted more widely for-designing and building IT systems. Enforcing contractual compliance needs to be modeled at different levels of a BPM framework, which also includes the service layer. In this paper, we discuss requirements and methods for modeling contractual compliance for an SOA-supported BPM. We also show how business rule management integrated into an industry BPM tool allows modeling and processing functional and non-functional-property constraints which may be extracted from business process contracts. This work proposes a framework that responds to the requirements identified and proposes an architecture implementing it. Our approach is also illustrated by an example.

  3. BPM CALIBRATION INDEPENDENT LHC OPTICS CORRECTION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    CALAGA,R.; TOMAS, R.; GIOVANNOZZI, M.

    2007-06-25

    The tight mechanical aperture for the LHC imposes severe constraints on both the beta and dispersion beating. Robust techniques to compensate these errors are critical for operation of high intensity beams in the LHC. We present simulations using realistic errors from magnet measurements and alignment tolerances in the presence of BPM noise. Correction reveals that the use of BPM calibration and model independent observables are key ingredients to accomplish optics correction. Experiments at RHIC to verify the algorithms for optics correction are also presented.

  4. Evaluation of Heat Dissipation in the BPM Buttons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Blednyhk, A.

    2009-05-04

    Growth of circulating current in the storage rings drastically increases heating of the beam position monitor (BPM) buttons due to the induced trapped modes is drastically increasing. Excessive heating can lead to the errors in the measuring of beam position or even catastrophic failures of the pick-up assembly. In this paper we present calculations of heat generated in the button for different geometries and materials. The obtained results are used for the optimization of the NSLS-II BPM buttons design.

  5. A BPM calibration procedure using TBT data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, M.J.; Crisp, J.; Prieto, P.

    2007-06-01

    Accurate BPM calibration is crucial for lattice analysis. It is also reassuring when the calibration can be independently verified. This paper outlines a procedure that can extract BPM calibration information from TBT orbit data. The procedure is developed as an extension to the Turn-By-Turn lattice analysis [1]. Its application to data from both Recycler Ring and Main Injector (MI) at Fermilab have produced very encouraging results. Some specifics in hardware design will be mentioned to contrast that of analysis results.

  6. Deep-Diving California Sea Lions: Are They Pushing Their Physiological Limit

    DTIC Science & Technology

    2015-09-30

    resting heart rate (70 bpm ) (Ponganis et al. 1997) is reached, and e) duration of and heart rate during the ascent tachycardia. If possible, heart rate...Resting heart rates were 54 + 6 beats min-1 ( bpm ), and in dives of 1-3 min, 3-5 min, and > 5 min, dive heart rates (number of beats/dive duration...were 55 + 8, 51 + 6, and 40 + bpm . As illustrated in Figs. 1 and 2, the heart rate profile was characterized by rapid development of a bradycardia

  7. Bending fatigue of electron-beam-welded foils. Application to a hydrodynamic air bearing in the Chrysler/DOE upgraded automotive gas tubine engine

    NASA Technical Reports Server (NTRS)

    Saltsman, J. F.; Halford, G. R.

    1984-01-01

    A hydrodynamic air bearing with a compliment surface is used in the gas generator of an upgraded automotive gas turbine engine. In the prototype design, the compliant surface is a thin foil spot welded at one end to the bearing cartridge. During operation, the foil failed along the line of spot welds which acted as a series of stress concentrators. Because of its higher degree of geometric uniformity, electron beam welding of the foil was selected as an alternative to spot welding. Room temperature bending fatigue tests were conducted to determine the fatigue resistance of the electron beam welded foils. Equations were determined relating cycles to crack initiation and cycles to failure to nominal total strain range. A scaling procedure is presented for estimating the reduction in cyclic life when the foil is at its normal operating temperature of 260 C (500 F).

  8. RICH upgrade in LHCb experiment

    NASA Astrophysics Data System (ADS)

    Pistone, A.; LHCb RICH Collaboration

    2017-01-01

    The LHCb experiment is dedicated to precision measurements of CP violation and rare decays of B hadrons at the Large Hadron Collider (LHC) at CERN (Geneva). The second long shutdown of the LHC is currently scheduled to begin in 2019. During this period the LHCb experiment with all its sub-detectors will be upgraded in order to run at an instantaneous luminosity of 2 × 10^{33} cm ^{-2} s ^{-1} , about a factor 5 higher than the current luminosity, and to read out data at a rate of 40MHz into a flexible software-based trigger. The Ring Imaging CHerenkov (RICH) system will require new photon detectors and modifications to the optics of the upstream detector. Tests of the prototype of the smallest constituent of the new RICH system have been performed during testbeam sessions at the North Area test beam facility at CERN in the last years.

  9. Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Upgrade Activities

    NASA Technical Reports Server (NTRS)

    Emrich, William J. Jr.; Moran, Robert P.; Pearson, J. Boise

    2012-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission and would be exposed to flowing hydrogen. Initial testing of a somewhat prototypical fuel element has been successfully performed in NTREES and the facility has now been shutdown to allow for an extensive reconfiguration of the facility which will result in a significant upgrade in its capabilities

  10. Field Quality from Tolerance Stack-up In R&D Quadrupoles for the Advanced Photon Source Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, J.; Jaski, M.; Dejus, R.

    2016-10-01

    The Advanced Photon Source (APS) at Argonne National Laboratory (ANL) is considering upgrading the current double-bend, 7-GeV, 3rd generation storage ring to a 6-GeV, 4th generation storage ring with a Multibend Achromat (MBA) lattice. In this study, a novel method is proposed to determine fabrication and assembly tolerances through a combination of magnetic and mechanical tolerance analyses. Mechanical tolerance stackup analyses using Teamcenter Variation Analysis are carried out to determine the part and assembly level fabrication tolerances. Finite element analyses using OPERA are conducted to estimate the effect of fabrication and assembly errors on the magnetic field of a quadrupolemore » magnet and to determine the allowable tolerances to achieve the desired magnetic performance. Finally, results of measurements in R&D quadrupole prototypes are compared with the analysis results.« less

  11. Performance of the prototype LaBr{sub 3} spectrometer developed for the JET gamma-ray camera upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rigamonti, D., E-mail: davide.rigamonti@mib.infn.it; Nocente, M.; Gorini, G.

    2016-11-15

    In this work, we describe the solution developed by the gamma ray camera upgrade enhancement project to improve the spectroscopic properties of the existing JET γ-ray camera. Aim of the project is to enable gamma-ray spectroscopy in JET deuterium-tritium plasmas. A dedicated pilot spectrometer based on a LaBr{sub 3} crystal coupled to a silicon photo-multiplier has been developed. A proper pole zero cancellation network able to shorten the output signal to a length of 120 ns has been implemented allowing for spectroscopy at MHz count rates. The system has been characterized in the laboratory and shows an energy resolution ofmore » 5.5% at E{sub γ} = 0.662 MeV, which extrapolates favorably in the energy range of interest for gamma-ray emission from fast ions in fusion plasmas.« less

  12. Upgrading the ATLAS Tile Calorimeter Electronics

    NASA Astrophysics Data System (ADS)

    Carrió, Fernando

    2013-11-01

    This work summarizes the status of the on-detector and off-detector electronics developments for the Phase 2 Upgrade of the ATLAS Tile Calorimeter at the LHC scheduled around 2022. A demonstrator prototype for a slice of the calorimeter including most of the new electronics is planned to be installed in ATLAS in the middle of 2014 during the first Long Shutdown. For the on-detector readout, three different front-end boards (FEB) alternatives are being studied: a new version of the 3-in-1 card, the QIE chip and a dedicated ASIC called FATALIC. The Main Board will provide communication and control to the FEBs and the Daughter Board will transmit the digitized data to the off-detector electronics in the counting room, where the super Read-Out Driver (sROD) will perform processing tasks on them and will be the interface to the trigger levels 0, 1 and 2.

  13. Increased Heart Rate Is Associated With Higher Mortality in Patients With Atrial Fibrillation (AF): Results From the Outcomes Registry for Better Informed Treatment of AF (ORBIT-AF)

    PubMed Central

    Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P

    2015-01-01

    Background Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. Methods and Results We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Conclusions Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. Clinical Trial Registration URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. PMID:26370445

  14. Evaluation of anti-asthmatic and antioxidant potential of Boerhavia procumbens in toluene diisocyanate (TDI) treated rats.

    PubMed

    Bokhari, Jasia; Khan, Muhammad Rashid

    2015-08-22

    Asthma is an ailment of airways characterized by activation of the T helper (Th) 2 lymphocytes and subsequent movement of inflammatory cells. Boerhavia procumbens of family Nyctaginaceae is locally used for the treatment of asthma, cough, hemorrhoids, dropsy, cardiac, eyes and kidney problems. We have evaluated its methanol extract (BPM) as a therapeutic candidate for asthma against toluene diisocyanate (TDI) allergic model in rat. The BPM extract was obtained from the whole plant of B. procumbens in methanol. Sprague-Dawley male 36 rats (200-250 g) were categorized into 6 groups having six rats in each category. The animals were provoked (10%) and sensitized (5%) by TDI. Animals of groups I-III were vehicle control (ethyl acetate), diseased control (TDI) and reference control (TDI+dexamethasone {2.5mg/kg bw}), respectively. Animals of group IV (TDI+200mg/kg bw) and group V (TDI+400mg/kg bw) were administered with BPM whereas group VI was administered with 400mg/kg bw alone of BPM. Protective effects of BPM were determined by counting the number of leucocytes and estimation of interleukines in blood, bronchoalveolar lavage (BAL) and in in vitro culture of spleen cells. Estimation of antioxidant enzymes, lipid peroxides and H2O2 and histopathology of lungs were carried out for antioxidant potential of plant extract used. Methanol extract of B. procumbens suppressed the asthmatic symptoms and inhibited the infiltration of eosinophils and lymphocytes in lungs of TDI provoked rats. Administration of BPM to TDI provoked rats, dose dependently, inhibited the release of interleukins (IL)-2 in serum and IL-4, IL-6 interferon gamma (IFN-γ) in bronchoalveolar lavage (BAL) and in in vitro culture of spleen cells, and ameliorated the oxidative stress in lung tissues. Quantitative scoring of the lung histopathology exhibited protective effects of BPM and the inflammation, mucus, thickening of peribronchial smooth muscle layer and subepithelial deposition of collagen induced with TDI were ameliorated. The BPM has the anti-inflammatory properties that may be used to treat the asthma and inflammatory related ailments. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  15. A preliminary study of a running speed based heart rate prediction during an incremental treadmill exercise.

    PubMed

    Dae-Geun Jang; Byung-Hoon Ko; Sub Sunoo; Sang-Seok Nam; Hun-Young Park; Sang-Kon Bae

    2016-08-01

    This preliminary study investigates feasibility of a running speed based heart rate (HR) prediction. It is basically motivated from the assumption that there is a significant relationship between HR and the running speed. In order to verify the assumption, HR and running speed data from 217 subjects of varying aerobic capabilities were simultaneously collected during an incremental treadmill exercise. A running speed was defined as a treadmill speed and its corresponding heart rate was calculated by averaging the last one minute HR values of each session. The feasibility was investigated by assessing a correlation between the heart rate and the running speed using inter-subject (between-subject) and intra-subject (within-subject) datasets with regression orders of 1, 2, 3, and 4, respectively. Furthermore, HR differences between actual and predicted HRs were also employed to investigate the feasibility of the running speed in predicting heart rate. In the inter-subject analysis, a strong positive correlation and a reasonable HR difference (r = 0.866, 16.55±11.24 bpm @ 1st order; r = 0.871, 15.93±11.49 bpm @ 2nd order; r = 0.897, 13.98±10.80 bpm @ 3rd order; and r = 0.899, 13.93±10.64 bpm @ 4th order) were obtained, and a very high positive correlation and a very low HR difference (r = 0.978, 6.46±3.89 bpm @ 1st order; r = 0.987, 5.14±2.87 bpm @ 2nd order; r = 0.996, 2.61±2.03 bpm @ 3rd order; and r = 0.997, 2.04±1.73 bpm @ 4th order) were obtained in the intra-subject analysis. It can therefore be concluded that 1) heart rate is highly correlated with a running speed; 2) heart rate can be approximately estimated by a running speed with a proper statistical model (e.g., 3rd-order regression); and 3) an individual HR-speed calibration process may improve the prediction accuracy.

  16. Increased Heart Rate Is Associated With Higher Mortality in Patients With Atrial Fibrillation (AF): Results From the Outcomes Registry for Better Informed Treatment of AF (ORBIT-AF).

    PubMed

    Steinberg, Benjamin A; Kim, Sunghee; Thomas, Laine; Fonarow, Gregg C; Gersh, Bernard J; Holmqvist, Fredrik; Hylek, Elaine; Kowey, Peter R; Mahaffey, Kenneth W; Naccarelli, Gerald; Reiffel, James A; Chang, Paul; Peterson, Eric D; Piccini, Jonathan P

    2015-09-14

    Most patients with atrial fibrillation (AF) require rate control; however, the optimal target heart rate remains under debate. We aimed to assess rate control and subsequent outcomes among patients with permanent AF. We studied 2812 US outpatients with permanent AF in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation. Resting heart rate was measured longitudinally and used as a time-dependent covariate in multivariable Cox models of all-cause and cause-specific mortality during a median follow-up of 24 months. At baseline, 7.4% (n=207) had resting heart rate <60 beats per minute (bpm), 62% (n=1755) 60 to 79 bpm, 29% (n=817) 80 to 109 bpm, and 1.2% (n=33) ≥110 bpm. Groups did not differ by age, previous cerebrovascular disease, heart failure status, CHA2DS2-VASc scores, renal function, or left ventricular function. There were significant differences in race (P=0.001), sinus node dysfunction (P=0.004), and treatment with calcium-channel blockers (P=0.006) and anticoagulation (P=0.009). In analyses of continuous heart rates, lower heart rate ≤65 bpm was associated with higher all-cause mortality (adjusted hazard ratio [HR], 1.15 per 5-bpm decrease; 95% CI, 1.01 to 1.32; P=0.04). Similarly, increasing heart rate >65 bpm was associated with higher all-cause mortality (adjusted HR, 1.10 per 5-bpm increase; 95% CI, 1.05 to 1.15; P<0.0001). This relationship was consistent across endpoints and in a broader sensitivity analysis of permanent and nonpermanent AF patients. Among patients with permanent AF, there is a J-shaped relationship between heart rate and mortality. These data support current guideline recommendations, and clinical trials are warranted to determine optimal rate control. URL: http://clinicaltrials.gov/. Unique identifier: NCT01165710. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  17. CCISS, Vascular and BP Reg: Canadian space life science research on ISS

    NASA Astrophysics Data System (ADS)

    Hughson, Richard L.; Shoemaker, J. Kevin; Arbeille, Philippe

    2014-11-01

    A comprehensive goal of the Canadian Space Agency studies (CCISS, Vascular and BP Reg) has been to investigate the efficacy of current exercise countermeasures to maintain cardiovascular and cerebrovascular health on return to Earth after up to 6-months in space. Results from the CCISS experiments revealed no significant change of in-flight heart rate during daily activities or sleep, and small, but variable between astronauts, post-flight elevation. The between astronaut differences were exaggerated during measurement of spontaneous baroreflex slope, which was reduced post-flight (P<0.05) during paced breathing with 3 astronauts having significant correlations between reduced baroreflex and reduced RR-interval (consistent with reduced fitness). Cerebrovascular autoregulation and CO2 response were mildly impaired after flight. Some loss of in-flight fitness of astronauts in Vascular was reflected by the increase in HR at a work rate of 161±46 W of 12.3±10.5 bpm, 10.4±5.9 bpm and 13.4±5.7 bpm for early-flight, late-flight and R+1, respectively. On return to gravity, changes in resting heart rate for supine (5.9±3.5 bpm), sit (8.1±3.3 bpm) and stand (10.3±10.0 bpm) were small but variable between individuals (from -5 bpm to +20 bpm in post-flight standing) and not related to the change in exercise heart rate. In Vascular astronauts, pulse wave transit time measured to the finger tended to be reduced post-flight and carotid artery distensibility was significantly reduced (P=0.03, and n=6). The heart rate and baroreflex data suggest that some astronauts return with cardiovascular deconditioning in spite of the exercise regimes. However, greater arterial stiffness is common among all astronauts studied to date. The new CSA project, BP Reg, will monitor inflight blood pressure in an attempt to identify astronauts in greater need for countermeasures. Future research should focus on whether Vascular changes in astronauts might make them an appropriate model to study the mechanisms of arterial aging on Earth.

  18. Concurrent validity of resting pulse-rate measurements: a comparison of 2 smartphone applications, the polar H7 belt monitor, and a pulse oximeter with bluetooth.

    PubMed

    Cheatham, Scott W; Kolber, Morey J; Ernst, Michael P

    2015-05-01

    Pulse rate is commonly measured manually or with commercial wrist or belt monitors. More recently, pulse-rate monitoring has become convenient with the use of mobile technology that allows monitoring through a smartphone camera. This optical technology offers many benefits, although the clinimetric properties have not been extensively studied. Observational study of reliability Setting: University kinesiology laboratory. 30 healthy, recreationally active adults. Concurrent measurement of pulse rate using 2 smartphone applications (fingertip, face-scan,) with the Polar H7 belt and pulse oximeter. Average resting pulse rate for 5 min in 3 positions (supine, sitting, and prone). Concurrent validity in supine and standing was good between the 2 applications and the Polar H7 (intraclass correlation coefficient [ICC] .80-.98) and pulse oximeter (ICC .82-.98). For sitting, the validity was good between the fingertip application, Polar H7 (ICC .97), and pulse oximeter (ICC .97). The face-scan application had moderate validity with the Polar H7 (ICC .74) and pulse oximeter (ICC .69). The minimal detectable change (MDC90) between the fingertip application and Polar H7 ranged from 1.38 to 4.36 beats/min (BPM) and from 0.69 to 2.97 BPM for the pulse oximeter with both positions. The MDC90 between the face-scan application and Polar H7 ranged from 11.88 to 12.83 BPM and from 0.59 to 17.72 BPM for the pulse oximeter. The 95% limits of agreement suggest that the fingertip application may vary between 2.40 and 3.59 BPM with the Polar H7 and between 3.40 and 3.42 BPM with the pulse oximeter. The face-scan application may vary between 3.46 and 3.52 BPM with the Polar H7 and between 2.54 and 3.46 BPM with the pulse oximeter. Pulse-rate measurements may be effective using a fingertip application, belt monitor, and pulse oximeter. The fingertip scanner showed superior results compared with the face scanner, which only demonstrated modest validity compared with the Polar H7 and pulse oximeter.

  19. Bladder pressure measurements and urinary tract infection in trauma patients.

    PubMed

    Duane, Therèse M; Young, Andrew; Weber, William; Wolfe, Luke G; Malhotra, Ajai K; Aboutanos, Michel B; Whelan, James F; Mayglothling, Julie; Ivatury, Rao R

    2012-04-01

    The purpose of this trial was to determine if using a closed technique for bladder pressure measurements (BPMs) would eliminate them as a risk factor for urinary tract infection (UTI) in trauma patients, as was shown previously using an open technique. Data were collected prospectively from January 2006 until December 2009 by a dedicated epidemiology nurse and combined with trauma registry data at our Level 1 trauma center. All trauma patients admitted to the surgical trauma intensive care unit (STICU) with and without UTIs were compared for demographic and epidemiologic data. A closed system was used in which the urinary drainage catheter (UDC) remained connected to the bag and 45 mL of saline was injected through a two-way valved sideport, with subsequent measurements through the sideport. There were 1,641 patients in the trial. The UTI group was sicker (Injury Severity Score [ISS] 18.7±11.9 no UTI vs. 28±10.7 UTI; p<0.0001), with longer stays (11.4±12.4 days no UTI vs. 37.9±20.3 days UTI; p<0.0001) and more UDC days (4.3±6.6 no UTI vs. 23.9±16.6 UTI; p<0.0001). The BPM group had more UDC days (15.6 days±16.0 BPM vs. 5.4 days±7.3 no BPM; p<0.0001), yet no difference in UTI rate/1,000 UDC days (5.7 no BPM vs. 8.0 BPM; p=0.5291). Logistic regression demonstrated only UDC days to be a predictor of UTI (1.125; 95% confidence interval [CI] 1.097-1.154; p<0.0001), whereas ISS (1.083, 95% CI 1.063-1.104; p<0.0001) and age (1.051, 95% CI 1.037-1.065; p<0.0001) were the only predictors of death. Although patients undergoing BPM have more UTIs than patients without BPM, the measurements are not an independent predictor of UTI when done by the closed technique. These findings emphasize the judicious use of BPM with a closed system and, more importantly, the need for early removal of catheters.

  20. Beam position reconstruction for the g2p experiment in Hall A at Jefferson Lab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhu, Pengjia; Allada, Kalyan; Allison, Trent

    2015-11-03

    Beam-line equipment was upgraded for experiment E08-027 (g2p) in Hall A at Jefferson Lab. Two beam position monitors (BPMs) were necessary to measure the beam position and angle at the target. A new BPM receiver was designed and built to handle the low beam currents (50-100 nA) used for this experiment. Two new super-harps were installed for calibrating the BPMs. In addition to the existing fast raster system, a slow raster system was installed. We found that before and during the experiment, these new devices were tested and debugged, and their performance was also evaluated. In order to achieve themore » required accuracy (1-2 mm in position and 1-2 mrad in angle at the target location), the data of the BPMs and harps were carefully analyzed, as well as reconstructing the beam position and angle event by event at the target location. Finally, the calculated beam position will be used in the data analysis to accurately determine the kinematics for each event.« less

  1. Improvement of the thermo-mechanical position stability of the beam position monitor in the PLS-II

    NASA Astrophysics Data System (ADS)

    Ha, Taekyun; Hong, Mansu; Kwon, Hyuckchae; Han, Hongsik; Park, Chongdo

    2016-09-01

    In the storage ring of the Pohang Light Source-II (PLS-II), we reduced the mechanical displacement of the electron-beam position monitors (e-BPMs) that is caused by heating during e-beam storage. The BPM pickup itself must be kept stable to sub-micrometer precision in order for a stable photon beam to be provided to beamlines because the orbit feedback system is programmed to make the electron beam pass through the center of the BPM. Thermal deformation of the vacuum chambers on which the BPM pickups are mounted is inevitable when the electron beam current is changed by an unintended beam abort. We reduced this deformation by improving the vacuum chamber support and by enhancing the water cooling. We report a thermo-mechanical analysis and displacement measurements for the BPM pickups after improvements.

  2. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    PubMed

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  3. Advances in industrial biopharmaceutical batch process monitoring: Machine-learning methods for small data problems.

    PubMed

    Tulsyan, Aditya; Garvin, Christopher; Ündey, Cenk

    2018-04-06

    Biopharmaceutical manufacturing comprises of multiple distinct processing steps that require effective and efficient monitoring of many variables simultaneously in real-time. The state-of-the-art real-time multivariate statistical batch process monitoring (BPM) platforms have been in use in recent years to ensure comprehensive monitoring is in place as a complementary tool for continued process verification to detect weak signals. This article addresses a longstanding, industry-wide problem in BPM, referred to as the "Low-N" problem, wherein a product has a limited production history. The current best industrial practice to address the Low-N problem is to switch from a multivariate to a univariate BPM, until sufficient product history is available to build and deploy a multivariate BPM platform. Every batch run without a robust multivariate BPM platform poses risk of not detecting potential weak signals developing in the process that might have an impact on process and product performance. In this article, we propose an approach to solve the Low-N problem by generating an arbitrarily large number of in silico batches through a combination of hardware exploitation and machine-learning methods. To the best of authors' knowledge, this is the first article to provide a solution to the Low-N problem in biopharmaceutical manufacturing using machine-learning methods. Several industrial case studies from bulk drug substance manufacturing are presented to demonstrate the efficacy of the proposed approach for BPM under various Low-N scenarios. © 2018 Wiley Periodicals, Inc.

  4. Effects of rhythmical and extra-rhythmical qualities of music on heart rate during stationary bike activities.

    PubMed

    DI Cagno, Alessandra; Iuliano, Enzo; Fiorilli, Giovanni; Aquino, Giovanna; Giombini, Arrigo; Menotti, Federica; Tsopani, Despina; Calcagno, Giuseppe

    2016-10-01

    The aim of this study was to evaluate the effects of rhythmical and extra-rhythmical qualities of music on the heart rate (HR) and rates of perceived exertion (RPE), during sub-maximal stationary bike activity. HR of 28 female adult participants was monitored during 3 session of physical activity, performed under 3 different conditions: Hi-BPM (music with 150-170 BPM), RHYTHM (rhythmical qualities only of Hi-BPM condition) and control condition without music (CONTROL). Four parameters were analyzed: the highest HR value (High-HR), High-HR minus starting HR (∆HR), time to reach the 75% of Maximal HR (MHR) (TimeTo75%) and time over 75% MHR (TimeOver75%). HR trend analysis was performed to evaluate differences among the three conditions. OMNI-Cycle Scale was administered to evaluate RPE. MANOVA showed significant differences between the three conditions in TimeTo75%, ∆HR (P<0.01) and TimeOver75% (P<0.05). In RHYTHM and CONTROL conditions after reaching 75% MHR, the HR increase were significantly lower than Hi-BPM (P<0.01). No significant differences were found in OMNI-Cycle Scale scores of Hi-BPM and RHYTHM whereas RPE was significantly higher in CONTROL condition (P<0.05). Hi-BPM and RHYTHM music allowed a faster reaching of the aerobic training zone compared to CONTROL conditions. Nevertheless, after 75% MHR, extra-rhythmical qualities are necessary to maintain or to increase the working HR levels.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The ATLAS collaboration at LHC has chosen the Micromegas (Micro Mesh Gaseous Structure) technology along with the small-strip Thin Gap Chambers (sTGC) for the high luminosity upgrade of the inner muon station in the high-rapidity region, the so called New Small Wheel (NSW). It employs eight layers of Micromegas detectors and eight layers of sTGC. The NSW project requires fully efficient Micromegas chambers with spatial resolution down to 100 μm in the precision coordinate for momentum reconstruction, and at mm level in the azimuthal (second) coordinate, over a total active area of 1200 m{sup 2}, with a rate capability upmore » to about 15 kHz/cm{sup 2} and operation in a moderate magnetic field up to B = 0.4 T. The required tracking capability is provided by the intrinsic space resolution combined with a mechanical precision at the level of 30 μm along the precision coordinate. Together with the precise tracking capability the Micromegas chambers should provide a trigger signal. Several tests have been performed on small (10x10 cm{sup 2}) and large (1 x 1 m{sup 2}) size single gap chambers prototypes using high energy hadron beams at CERN, low and intermediate energy (0.5-5 GeV) electron beams at Frascati and DESY, neutron beams at Demokritos (Athens) and Garching (Munich) and cosmic rays. More recently two quadruplets with dimensions 1.2 x 0.5 m{sup 2} and the same configuration and structure foreseen for the NSW upgrade have been built at CERN and tested with high energy pions/muons beam. Results obtained in the most recent tests, in different configurations and operating conditions, in dependence with the magnetic field, will be presented, along with a comparison between different read-out electronics, either based on the APV25 chips, or based on a new digital front-end ASIC developed in its second version (VMM2) as a new prototype of the final chip that will be employed in the NSW upgrade. (authors)« less

  6. Adherence to optimal heart rate control in heart failure with reduced ejection fraction: insight from a survey of heart rate in heart failure in Sweden (HR-HF study).

    PubMed

    Fu, M; Ahrenmark, U; Berglund, S; Lindholm, C J; Lehto, A; Broberg, A Månsson; Tasevska-Dinevska, G; Wikstrom, G; Ågard, A; Andersson, B

    2017-12-01

    Despite that heart rate (HR) control is one of the guideline-recommended treatment goals for heart failure (HF) patients, implementation has been painstakingly slow. Therefore, it would be important to identify patients who have not yet achieved their target heart rates and assess possible underlying reasons as to why the target rates are not met. The survey of HR in patients with HF in Sweden (HR-HF survey) is an investigator-initiated, prospective, multicenter, observational longitudinal study designed to investigate the state of the art in the control of HR in HF and to explore potential underlying mechanisms for suboptimal HR control with focus on awareness of and adherence to guidelines for HR control among physicians who focus on the contributing role of beta-blockers (BBs). In 734 HF patients the mean HR was 68 ± 12 beats per minute (bpm) (37.2% of the patients had a HR >70 bpm). Patients with HF with reduced ejection fraction (HFrEF) (n = 425) had the highest HR (70 ± 13 bpm, with 42% >70 bpm), followed by HF with preserved ejection fraction and HF with mid-range ejection fraction. Atrial fibrillation, irrespective of HF type, had higher HR than sinus rhythm. A similar pattern was observed with BB treatment. Moreover, non-achievement of the recommended target HR (<70 bpm) in HFrEF and sinus rhythm was unrelated to age, sex, cardiovascular risk factors, cardiovascular diseases, and comorbidities, but was related to EF and the clinical decision of the physician. Approximately 50% of the physicians considered a HR of >70 bpm optimal and an equal number considered a HR of >70 bpm too high, but without recommending further action. Furthermore, suboptimal HR control cannot be attributed to the use of BBs because there was neither a difference in use of BBs nor an interaction with BBs for HR >70 bpm compared with HR <70 bpm. Suboptimal control of HR was noted in HFrEF with sinus rhythm, which appeared to be attributable to physician decision making rather than to the use of BBs. Therefore, our results underline the need for greater attention to HR control in patients with HFrEF and sinus rhythm and thus a potential for improved HF care.

  7. A literature review on business process modelling: new frontiers of reusability

    NASA Astrophysics Data System (ADS)

    Aldin, Laden; de Cesare, Sergio

    2011-08-01

    Business process modelling (BPM) has become fundamental for modern enterprises due to the increasing rate of organisational change. As a consequence, business processes need to be continuously (re-)designed as well as subsequently aligned with the corresponding enterprise information systems. One major problem associated with the design of business processes is reusability. Reuse of business process models has the potential of increasing the efficiency and effectiveness of BPM. This article critically surveys the existing literature on the problem of BPM reusability and more specifically on that State-of-the-Art research that can provide or suggest the 'elements' required for the development of a methodology aimed at discovering reusable conceptual artefacts in the form of patterns. The article initially clarifies the definitions of business process and business process model; then, it sets out to explore the previous research conducted in areas that have an impact on reusability in BPM. The article concludes by distilling directions for future research towards the development of apatterns-based approach to BPM; an approach that brings together the contributions made by the research community in the areas of process mining and discovery, declarative approaches and ontologies.

  8. Event-synchronized data acquisition system for the SPring-8 linac beam position monitors

    NASA Astrophysics Data System (ADS)

    Masuda, T.; Fukui, T.; Tanaka, R.; Taniuchi, T.; Yamashita, A.; Yanagida, K.

    2005-05-01

    By the summer of 2003, we had completed the installation of a new non-destructive beam position monitor (BPM) system to facilitate beam trajectory and energy correction for the SPring-8 linac. In all, 47 BPM sets were installed on the 1-GeV linac and three beam-transport lines. All of the BPM data acquisition system was required to operate synchronously with the electron beam acceleration cycle. We have developed an event-synchronized data acquisition system for the BPM data readout. We have succeeded in continuously taking all the BPMs data from six VME computers synchronized with the 10 pps operation of the linac to continuously acquire data. For each beam shot, the data points are indexed by event number and stored in a database. Using the real-time features of the Solaris operating system and distributed database technology, we currently have achieved about 99.9% efficiency in capturing and archiving all of the 10 Hz data. The linac BPM data is available for off-line analysis of the beam trajectory, but also for real-time control and automatic correction of the beam trajectory and energy.

  9. Trigger readout electronics upgrade for the ATLAS Liquid Argon Calorimeters

    NASA Astrophysics Data System (ADS)

    Dinkespiler, B.

    2017-09-01

    The upgrade of the Large Hadron Collider (LHC) scheduled for the 2019-2020 shut-down period, referred to as Phase-I upgrade, will increase the instantaneous luminosity to about three times the design value. Since the current ATLAS trigger system does not allow sufficient increase of the trigger rate, an improvement of the trigger system is required. The Liquid Argon (LAr) Calorimeter read-out will therefore be modified to deliver digital trigger signals with a higher spatial granularity in order to improve the identification efficiencies of electrons, photons, tau, jets and missing energy, at high background rejection rates at the Level-1 trigger. The new trigger signals will be arranged in 34000 so-called Super Cells which achieves 5-10 times better granularity than the trigger towers currently used and allows an improved background rejection. The readout of the trigger signals will process the signal of the Super Cells at every LHC bunch-crossing at 12-bit precision and a frequency of 40 MHz. The data will be transmitted to the Back End using a custom serializer and optical converter and 5.12 Gb/s optical links. In order to verify the full functionality of the future Liquid Argon trigger system, a demonstrator set-up has been installed on the ATLAS detector and is operated in parallel to the regular ATLAS data taking during the LHC Run-2 in 2015 and 2016. Noise level and linearity on the energy measurement have been verified to be within our requirements. In addition, we have collected data from 13 TeV proton collisions during the LHC 2015 and 2016 runs, and have observed real pulses from the detector through the demonstrator system. The talk will give an overview of the Phase-I Upgrade of the ATLAS Liquid Argon Calorimeter readout and present the custom developed hardware including their role in real-time data processing and fast data transfer. This contribution will also report on the performance of the newly developed ASICs including their radiation tolerance and on the performance of the prototype boards in the demonstrator system based on various measurements with the 13 TeV collision data. Results of the high-speed link test with the prototypes of the final electronic boards will be also reported.

  10. Upgrade of the ATLAS Tile Calorimeter Electronics

    NASA Astrophysics Data System (ADS)

    Moreno, Pablo; ATLAS Tile Calorimeter System

    2016-04-01

    The Tile Calorimeter (TileCal) is the hadronic calorimeter covering the central region of the ATLAS experiment at LHC. The TileCal readout consists of 9852 channels. The bulk of its upgrade will occur for the High Luminosity LHC phase (Phase II) where the peak luminosity will increase 5× compared to the design luminosity (1034 cm-2s-1) at center of mass energy of 14 TeV. The TileCal upgrade aims at replacing the majority of the on- and off-detector electronics to the extent that all calorimeter signals will be digitized and sent to the off-detector electronics in the counting room. To achieve the required reliability, redundancy has been introduced at different levels. Three different options are presently being investigated for the front-end electronic upgrade. Extensive test beam studies will determine which option will be selected. 10.24 Gbps optical links are used to read out all digitized data to the counting room while 4.8 Gbps down-links are used for synchronization, configuration and detector control. For the off-detector electronics a pre-processor (sROD) is being developed, which takes care of the initial trigger processing while temporarily storing the main data flow in pipeline and de-randomizer memories. Field Programmable Gate Arrays are extensively used for the logic functions off- and on-detector. One demonstrator prototype module with the new calorimeter module electronics, but still compatible with the present system, is planned to be inserted in ATLAS at the end of 2015.

  11. UKIRT Upgrades Program: design and installation of the Dome Ventilation System (DVS)

    NASA Astrophysics Data System (ADS)

    Neff, D. H.; Hileman, Edward A.; Kain, S. J.; Cavedoni, Charles P.; Chuter, Timothy C.

    1997-03-01

    In order to encourage adequate dome ventilation to reduce or eliminate dome seeing at the 3.8 m United Kingdom Infrared Telescope (UKIRT), a dome ventilation system (DVS) was designed to be installed in the lower dome skirt. The modifications to the dome for the new DVS apertures consisted of installing a reinforcing frame containing an insulated rollup door and adjustable louvers. This paper describes the finite element structural analysis of the reinforcing frame, the detailed design of the frame hardware, the design of the programmable language control (PLC) system for controlling the opening and closing of the rollup doors, and the fabrication and installation of a prototype frame assembly. To date, a prototype assembly has been installed that confirms the design, and fifteen production assemblies are currently under fabrication for installation by September 1996.

  12. [Successful outcome of a pregnancy with an extremely low fetal heart rate (34 bpm) due to isolated complete heart block--case report].

    PubMed

    Hamela-Olkowska, Anita; Dangel, Joanna; Miszczak-Knecht, Maria

    2009-09-01

    Isolated complete congenital heart block (CHB) in the majority of cases is associated with the presence of autoantibodies to SSA (Ro) and SSB (La) antigens in the maternal serum. The prognosis is less favorable in fetuses with a ventricular rate < 55bpm. We have reported a case of a fetus with an isolated non-autoimmune CHB with an extremely low ventricular rate (34bpm) in which the outcome was favorable. In the neonate the non-compaction of the myocardium was diagnosed.

  13. Utilizing the N beam position monitor method for turn-by-turn optics measurements

    NASA Astrophysics Data System (ADS)

    Langner, A.; Benedetti, G.; Carlà, M.; Iriso, U.; Martí, Z.; de Portugal, J. Coello; Tomás, R.

    2016-09-01

    The N beam position monitor method (N -BPM) which was recently developed for the LHC has significantly improved the precision of optics measurements that are based on BPM turn-by-turn data. The main improvement is due to the consideration of correlations for statistical and systematic error sources, as well as increasing the amount of BPM combinations which are used to derive the β -function at one location. We present how this technique can be applied at light sources like ALBA, and compare the results with other methods.

  14. Differences Among a Modern Cohort of BRCA Mutation Carriers Choosing Bilateral Prophylactic Mastectomies Compared to Breast Surveillance.

    PubMed

    Gilbert, Elizabeth; Zabor, Emily C; Stempel, Michelle; Mangino, Debra; Heerdt, Alexandra; Pilewskie, Melissa

    2017-10-01

    Women with a BRCA mutation have significantly elevated breast cancer risk, which can be reduced by >90% with bilateral prophylactic mastectomy (BPM). We sought to compare a cohort of BRCA mutation carriers choosing BPM versus breast surveillance to better elucidate factors that may impact decision making. Women with a BRCA mutation were retrospectively identified from a prospectively maintained database. The surveillance cohort (n = 313) consisted of women seen in a high-risk clinic between 2014 and 2016, while the surgery cohort (n = 142) consisted of women who underwent BPM between 2010 and 2016. Clinical and familial factors were compared between the groups. Women choosing BPM were more likely to have a BRCA1 than BRCA2 mutation compared with the surveillance group (57 vs. 45%, p = 0.02) and were less likely to have a personal history of ovarian cancer (10 vs. 20%, p = 0.01). Furthermore, women undergoing BPM were more likely to be married (78 vs. 62%, p = 0.01), to have more children (median 2 vs. 1, p < 0.001), and to have undergone a prophylactic oophorectomy (61 vs. 37%, p < 0.001). Women choosing BPM had more first-degree relatives (63 vs. 48%, p = 0.01) or a sister (23 vs. 14%, p = 0.02) with a history of breast cancer and were more likely to have a family member with ovarian cancer under the age of 40 years (9 vs. 4%, p = 0.03). There was no difference in the number of prior breast biopsies or history of atypia/lobular carcinoma in situ. The decision to undergo BPM appears multifactorial, with gene mutation, family history, and relationships appearing to have the strongest influence on decision making.

  15. Heart Rate Dependency of Large Artery Stiffness.

    PubMed

    Tan, Isabella; Spronck, Bart; Kiat, Hosen; Barin, Edward; Reesink, Koen D; Delhaas, Tammo; Avolio, Alberto P; Butlin, Mark

    2016-07-01

    Carotid-femoral pulse wave velocity (cfPWV) quantifies large artery stiffness, it is used in hemodynamic research and is considered a useful cardiovascular clinical marker. cfPWV is blood pressure (BP) dependent. Intrinsic heart rate (HR) dependency of cfPWV is unknown because increasing HR is commonly accompanied by increasing BP. This study aims to quantify cfPWV dependency on acute, sympathovagal-independent changes in HR, independent of BP. Individuals (n=52, age 40-93 years, 11 female) with in situ cardiac pacemakers or cardioverter defibrillators were paced at 60, 70, 80, 90, and 100 bpm. BP and cfPWV were measured at each HR. Both cfPWV (mean [95% CI], 0.31 [0.26-0.37] m/s per 10 bpm; P<0.001) and central aortic diastolic pressure (3.78 [3.40-4.17] mm Hg/10 bpm; P<0.001) increased with HR. The HR effect on cfPWV was isolated by correcting the BP effects by 3 different methods: (1) statistically, by a linear mixed model; (2) mathematically, using an exponential relationship between BP and cross-sectional lumen area; and (3) using measured BP dependency of cfPWV derived from changes in BP induced by orthostatic changes (seated and supine) in a subset of subjects (n=17). The BP-independent effects of HR on cfPWV were quantified as 0.20 [0.11-0.28] m/s per 10 bpm (P<0.001, method 1), 0.16 [0.11-0.22] m/s per 10 bpm (P<0.001, method 2), and 0.16 [0.11-0.21] m/s per 10 bpm (P<0.001, method 3). With a mean HR dependency in the range of 0.16 to 0.20 m/s per 10 bpm, cfPWV may be considered to have minimal physiologically relevant changes for small changes in HR, but larger differences in HR must be considered as contributing to significant differences in cfPWV. © 2016 American Heart Association, Inc.

  16. Heart rate is a prognostic risk factor for myocardial infarction: a post hoc analysis in the PERFORM (Prevention of cerebrovascular and cardiovascular Events of ischemic origin with teRutroban in patients with a history oF ischemic strOke or tRansient ischeMic attack) study population.

    PubMed

    Fox, Kim; Bousser, Marie-Germaine; Amarenco, Pierre; Chamorro, Angel; Fisher, Marc; Ford, Ian; Hennerici, Michael G; Mattle, Heinrich P; Rothwell, Peter M

    2013-10-09

    Elevated resting heart rate is known to be detrimental to morbidity and mortality in cardiovascular disease, though its effect in patients with ischemic stroke is unclear. We analyzed the effect of baseline resting heart rate on myocardial infarction (MI) in patients with a recent noncardioembolic cerebral ischemic event participating in PERFORM. We compared fatal or nonfatal MI using adjusted Cox proportional hazards models for PERFORM patients with baseline heart rate <70 bpm (n=8178) or ≥70 bpm (n=10,802). In addition, heart rate was analyzed as a continuous variable. Other cerebrovascular and cardiovascular outcomes were also explored. Heart rate ≥70 bpm was associated with increased relative risk for fatal or nonfatal MI (HR 1.32, 95% CI 1.03-1.69, P=0.029). For every 5-bpm increase in heart rate, there was an increase in relative risk for fatal and nonfatal MI (11.3%, P=0.0002). Heart rate ≥70 bpm was also associated with increased relative risk for a composite of fatal or nonfatal ischemic stroke, fatal or nonfatal MI, or other vascular death (excluding hemorrhagic death) (P<0001); vascular death (P<0001); all-cause mortality (P<0001); and fatal or nonfatal stroke (P=0.04). For every 5-bpm increase in heart rate, there were increases in relative risk for fatal or nonfatal ischemic stroke, fatal or nonfatal MI, or other vascular death (4.7%, P<0.0001), vascular death (11.0%, P<0.0001), all-cause mortality (8.0%, P<0.0001), and fatal and nonfatal stroke (2.4%, P=0.057). Elevated heart rate ≥70 bpm places patients with a noncardioembolic cerebral ischemic event at increased risk for MI. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  17. Tannate complexes of antihistaminic drug: sustained release and taste masking approaches.

    PubMed

    Rahman, Ziyaur; Zidan, Ahmed S; Berendt, Robert T; Khan, Mansoor A

    2012-01-17

    The aim of this investigation was to evaluate the complexation potential of brompheniramine maleate (BPM) and tannic acid (TA) for sustained release and taste masking effects. The complexes (1:1-1:7 TA to BPM ratio) were prepared by the solvent evaporation method using methanol, phosphate buffer pH 6.8 or 0.1N HCl as common solvents. The complexes were characterized microscopically by scanning electron microscopy (SEM), chemically by Fourier transform infrared (FTIR) and solid-state NMR (SSNMR), thermally by differential scanning calorimetry (DSC), for crystallinity by powder X-ray powder diffraction (PXRD), for organoleptic evaluation by electronic tongue (e-tongue), and for solubility in 0.1N HCl and phosphate buffer pH 6.8. The dissolution studies were carried out using the USP II method at 50 rpm in 500 ml of dissolution media (0.1N HCl or phosphate buffer pH 6.8). SEM images revealed that the morphology of complexes were completely different from the individual components, and all complexes had the same morphological characteristics, irrespective of the solvent used for their preparation, pH or ratio of BPM and TA. The FTIR spectra showed the presence of chemical interactions between the TA and BPM. DSC, PXRD and SSNMR indicated that the drug lost its crystalline nature by formation of the complex. Complexation has significantly reduced the solubility of BPM and sustained the drug release up to 24h in phosphate buffer pH 6.8 media. The bitter taste of the BPM was completely masked which was indicated by Euclidean distance values which was far from the drug but near to its placebo in the complexes in all ratios studied. The taste masked complexes can be potentially developed as suitable dosage forms for pediatric use. In summary, complexation of BPM and TA effectively sustained the dissolution and masked the bitter taste of drug for the development of suitable dosage forms for pediatric use. Published by Elsevier B.V.

  18. Comparing the Effects of Rest and Massage on Return to Homeostasis Following Submaximal Aerobic Exercise: a Case Study

    PubMed Central

    Resnick, Portia B.

    2016-01-01

    Introduction Postexercise massage can be used to help promote recovery from exercise on the cellular level, as well as systemically by increasing parasympathetic activity. No studies to date have been done to assess the effects of massage on postexercise metabolic changes, including excess postexercise oxygen consumption (EPOC). The purpose of this study was to compare the effects of massage recovery and resting recovery on a subject’s heart rate variability and selected metabolic effects following a submaximal treadmill exercise session. Methods One healthy 24-year-old female subject performed 30 minutes of submaximal treadmill exercise prior to resting or massage recovery sessions. Metabolic data were collected throughout the exercise sessions and at three 10 minute intervals postexercise. Heart rate variability was evaluated for 10 minutes after each of two 30-minute recovery sessions, either resting or massage. Results Heart rate returned to below resting levels (73 bpm) with 30 and 60 minutes of massage recovery (72 bpm and 63 bpm, respectively) compared to 30 and 60 minutes of resting recovery (77 bpm and 74 bpm, respectively). Heart rate variability data showed a more immediate shift to the parasympathetic state following 30 minutes of massage (1.152 LF/HF ratio) versus the 30-minute resting recovery (6.91 LF/HF ratio). It took 60 minutes of resting recovery to reach similar heart rate variability levels (1.216 LF/HF) found after 30 minutes of massage. Ventilations after 30 minutes of massage recovery averaged 7.1 bpm compared to 17.9 bpm after 30 minutes of resting recovery. Conclusions No differences in EPOC were observed through either the resting or massage recovery based on the metabolic data collected. Massage was used to help the subject shift into parasympathetic activity more quickly than rest alone following a submaximal exercise session. PMID:26977215

  19. LCLS-II Cryomodules Production at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arkan, Tug; Grimm, Chuck; Kaluzny, Joshua

    2017-05-01

    LCLS-II is an upgrade project for the linear coherent light source (LCLS) at SLAC. The LCLS-II linac will consist of thirty-five 1.3 GHz and two 3.9 GHz superconducting RF continuous wave (CW) cryomodules that Fermilab and Jefferson Lab (JLab) will assemble in collaboration with SLAC. The LCLS-II 1.3 GHz cryomodule design is based on the European XFEL pulsed-mode cryomodule design with modifications needed for CW operation. Fermilab and JLab will each assemble and test a prototype 1.3 GHz cryomodule to assess the results of the CW modifications, in advance of 16 and 17 production 1.3 GHz cryomodules, respectively. Fermilab ismore » solely responsible for the 3.9 GHz cryomodules. After the prototype cryomodule tests are complete and lessons learned incorporated, both laboratories will increase their cryomodule production rates to meet the challenging LCLS-II project requirement of approximately one cryomodule per month per laboratory. This paper presents the Fermilab Cryomodule Assembly Facility (CAF) infrastructure for LCLS-II cryomodule production, the Fermilab prototype 1.3 GHz CW cryomodule (pCM) assembly and readiness for production assembly.« less

  20. Design and prototype tests of a seismic attenuation system for the advanced-LIGO output mode cleaner

    NASA Astrophysics Data System (ADS)

    Bertolini, A.; DeSalvo, R.; Galli, C.; Gennaro, G.; Mantovani, M.; Márka, S.; Sannibale, V.; Takamori, A.; Torrie, C.

    2006-04-01

    Both present LIGO and advanced LIGO (Ad-LIGO) will need an output mode cleaner (OMC) to reach the desired sensitivity. We designed a suitable OMC seismically attenuated optical table fitting to the existing vacuum chambers (horizontal access module, HAM chambers). The most straightforward and cost-effective solution satisfying the Ad-LIGO seismic attenuation specifications was to implement a single passive seismic attenuation stage, derived from the 'seismic attenuation system' (SAS) concept. We built and tested prototypes of all critical components. On the basis of these tests and past experience, we expect that the passive attenuation performance of this new design, called HAM-SAS, will match all requirements for the LIGO OMC, and all Ad-LIGO optical tables. Its performance can be improved, if necessary, by implementation of a simple active attenuation loop at marginal additional cost. The design can be easily modified to equip the LIGO basic symmetric chamber (BSC) chambers and leaves space for extensive performance upgrades for future evolutions of Ad-LIGO. Design parameters and prototype test results are presented.

  1. A wire scanner system for characterizing the BNL energy recovery LINAC beam position monitor system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michnoff R.; Biscardi, C.; Cerniglia, P.

    2012-04-15

    A stepper motor controlled wire scanner system has recently been modified to support testing of the Brookhaven National Laboratory (BNL) Collider-Accelerator department's Energy Recovery Linac (ERL) beam position monitor (BPM) system. The ERL BPM consists of four 9.33 mm diameter buttons mounted at 90 degree spacing in a cube with 1.875 inch inside diameter. The buttons were designed by BNL and fabricated by Times Microwave Systems. Libera brilliance single pass BPM electronic modules with 700 MHz bandpass filter, manufactured by Instrumentation Technologies, will be used to measure the transverse beam positions at 14 locations around the ERL. The wire scannermore » assembly provides the ability to measure the BPM button response to a pulsed wire, and evaluate and calibrate the Libera position measurement electronics. A description of the wire scanner system and test result data will be presented.« less

  2. Democratizing Process Innovation? On Citizen Involvement in Public Sector BPM

    NASA Astrophysics Data System (ADS)

    Niehaves, Björn; Malsch, Robert

    ‘Open Innovation’ has been heavily discussed for product innovations; however, an information systems (IS) perspective on ‘process innovation’ has not yet been taken. Analyzing the example of the public sector in Germany, the paper seeks to investigate the factors that hinder and support ‘open process innovation’, a concept we define as the involvement of citizens in business process management (BPM) activities. With the help of a quantitative study (n=358), six factors are examined for their impact on citizen involvement in local government BPM initiatives. The results show that citizen involvement in reform processes is not primarily motivated by the aim of cost reduction, but rather related to legitimacy reasons and the intent to increase employee motivation. Based on these findings, implications for (design) theory and practice are discussed: Instead of detailed collaborative business processes modeling, the key of citizen involvement in public sector BPM lies in communication and mutual understanding.

  3. Optimization of pharmacotherapy in chronic heart failure: is heart rate adequately addressed?

    PubMed

    Franke, Jennifer; Wolter, Jan Sebastian; Meme, Lillian; Keppler, Jeannette; Tschierschke, Ramon; Katus, Hugo A; Zugck, Christian

    2013-01-01

    The aim of the study is to evaluate the use of beta-blockers in chronic heart failure (CHF) and the extent of heart rate reduction achieved in clinical practice and to determine differences in outcome of patients who fulfilled select inclusion criteria of the SHIFT study according to resting heart rate modulated by beta-blocker therapy. We evaluated an all-comer population of our dedicated CHF outpatient clinic between 2006 and 2010. For inclusion, individually optimized doses of guideline-recommended pharmacotherapy including beta-blockers had to be maintained for at least 3 months and routine follow-up performed at our outpatient CHF-clinic thereafter. Treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate were assessed. The outcome of patients who fulfilled select inclusion criteria of the SHIFT study (left-ventricular ejection fraction (LVEF) ≤35 %, sinus rhythm, NYHA II-IV) and were followed-up for at least 1 year was stratified according to resting heart rates: ≥75 versus <75 bpm and ≥70 versus <70 bpm. The composite primary endpoint was defined as all-cause death or hospital admission for worsening heart failure during 12-month follow-up. In total, 3,181 patients were assessed in regard to treatment dosages of beta-blockers, and demographic and clinical profiles including resting heart rate. Of the overall studied population, 443 patients fulfilled all inclusion criteria and entered outcome analysis. Median observation time of survivors was 27.5 months with 1,039.7 observation-years in total. Up-titration to at least half the evidence-based target dose of beta-blockers was achieved in 69 % and full up-titration in 29 % of these patients. Patients with increased heart rates were younger, more often male, exhibited a higher NYHA functional class and lower LVEF. The primary endpoint occurred in 21 % of patients in the ≥70 bpm group versus 9 % of patients in the group with heart rates <70 bpm (p <0.01). Likewise, comparing the groups ≥75 and <75 bpm, the primary endpoint was significantly increased in the group of patients with heart rates ≥75 bpm 27 vs. 12.2 %; p < 0.01). 5-year event-free survival was significantly lower among patients with heart rates ≥70 bpm as compared to those with <70 bpm (log-rank test p < 0.05) and among patients in the ≥75 bpm group versus <75 bpm group (log-rank test p < 0.01). In conclusion, in clinical practice, 53 % of CHF patients have inadequate heart rate control (heart rates ≥75 bpm) despite concomitant beta-blocker therapy. In this non-randomized cohort, adequate heart rate control under individually optimized beta-blocker therapy was associated with improved mid- and long-term clinical outcome up to 5 years. As further up titration of beta-blockers is not achievable in many patients, the administration of a selective heart rate lowering agent, such as ivabradine adjuvant to beta-blockers may pose an opportunity to further modulate outcome.

  4. Metal-Organic Frameworks of Pyrazolate Derivatives: Synthesis and Applications for Chemical Sensing, Gas Separation, and Catalysis

    NASA Astrophysics Data System (ADS)

    Kivi, Charlie Eric William

    In this work we examine the structure and applications of metal-organic frameworks (MOFs) synthesized from pyrazolate derivatives. In total, six pyrazolate ligands were examined: 4-(4-(3,5-dimethyl-1H-pyrazol-4-yl)phenyl)pyridine (HL), 1,1'-methylenebis(3,5-dimethyl-1H-pyrazolyl-4-carboxylic acid) (H2BPM), triethyl-1,1',1''-methanetriyltris(3,5-dimethyl-1H-pyrazole-4-carboxylate) (TPM-1), triethyl-4,4',4''-(methanetriyltris[3,5-dimethyl-1H-pyrazole-1,4-diyl])tribenzoate (TPM-2), 1,1',1'',1'''-(propane-1,1,3,3-tetrayl)tetrakis(3,5-dimethyl-1H-pyrazole-4-carboxylic acid) (H4TPP), tetraethyl-1,1',1'',1'''-(1,4-phenylenebis[methanetriyl]) tetrakis(3,5-dimethyl-1H-pyrazole-4-carboxylate)pyridinephenylpyrazole ( TPX). These ligands were used to synthesize a variety of MOFs that were subsequently investigated for luminescent sensing, gas storage, and catalytic performance. In Chapter 2, three MOFs synthesized from the reaction of HL and CuX (X = Br, I) were investigated. These materials were found to form MOFs which contained the luminescent trinuclear Cu(I) pyrazolate unit. Only CuBr and HL alone resulted in a MOF of sufficient purity and stability to permit evaluation as a luminescent sensor. Experiments with various volatile organic compounds revealed turn-on (luminescence enhancement) behaviour for ethyl acetate, pentane, and benzene and turn-off (luminescence quenching) behaviour for diethyl ether and chloroform for this material. In Chapters 3 and 4, ten MOFs are described. These were synthesized from H2BPM and metal-acetate salts. Chapter 3 encompassed two MOFs: [Ni(BPM)]n·xDMSO and [Cd(BPM)]n·xDMSO. These MOFs are isostructural, microporous materials. Evacuation of the pores led to collapse of the [Cd(BPM)]n·xDMSO material but [Ni(BPM)]n·xDMSO proved to be permanently porous. Further investigations revealed [Ni(BPM)] n·xDMSO selectively adsorbed methane over nitrogen indicating it may serve as a porous material for coal mine methane capture. Chapter 4 investigated the many other structures H2BPM can assume in the presence of manganese, cobalt, iron, copper, and europium. Cobalt in particular proved highly tunable with 4 separate structures being synthesized such as [Co2(BPM)2(H2 O)4(Bpy)0.5]n·2DMF·2(H 2O). This was achieved through varying the synthetic conditions. [Co 2(BPM)2(H2O)4(Bpy) 0.5]n·2DMF·2(H2O)and [Eu( BPM)(OAc)]n were further investigated for the oxidation of olefins and luminescence respectively. In Chapter 5, metal complexes Mo(TPM-1)(CO)3, Mo(TPM-2)(CO)3, Pd2(H4TPP )Cl4, and Pd2(TPX)Cl4 were synthesized. The catalytic performance of Mo(TPM-1)(CO) 3 was evaluated and found to be effective for the oxidation of olefins. MOF synthesis was attempted with all four compounds but was ultimately unsuccessful. Although one MOF was produced from Mo(TPM-1)(CO)3, large scale synthesis was not possible preventing full investigation of its properties.

  5. Vertically polarizing undulator with the dynamic compensation of magnetic forces for the next generation of light sources

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strelnikov, N.; Budker Institute of Nuclear Physics, Novosibirsk 630090; Trakhtenberg, E.

    2014-11-15

    A short prototype (847-mm-long) of an Insertion Device (ID) with the dynamic compensation of ID magnetic forces has been designed, built, and tested at the Advanced Photon Source (APS) of the Argonne National Laboratory. The ID magnetic forces were compensated by the set of conical springs placed along the ID strongback. Well-controlled exponential characteristics of conical springs permitted a very close fit to the ID magnetic forces. Several effects related to the imperfections of actual springs, their mounting and tuning, and how these factors affect the prototype performance has been studied. Finally, series of tests to determine the accuracy andmore » reproducibility of the ID magnetic gap settings have been carried out. Based on the magnetic measurements of the ID B{sub eff}, it has been demonstrated that the magnetic gaps within an operating range were controlled accurately and reproducibly within ±1 μm. Successful tests of this ID prototype led to the design of a 3-m long device based on the same concept. The 3-m long prototype is currently under construction. It represents R and D efforts by the APS toward APS Upgrade Project goals as well as the future generation of IDs for the Linac Coherent Light Source (LCLS)« less

  6. Differential Resting-State Functional Connectivity of Striatal Subregions in Bipolar Depression and Hypomania

    PubMed Central

    Altinay, Murat I.; Hulvershorn, Leslie A.; Karne, Harish; Beall, Erik B.

    2016-01-01

    Abstract Bipolar disorder (BP) is characterized by periods of depression (BPD) and (hypo)mania (BPM), but the underlying state-related brain circuit abnormalities are not fully understood. Striatal functional activation and connectivity abnormalities have been noted in BP, but consistent findings have not been reported. To further elucidate striatal abnormalities in different BP states, this study investigated differences in resting-state functional connectivity of six striatal subregions in BPD, BPM, and healthy control (HC) subjects. Ninety medication-free subjects (30 BPD, 30 BPM, and 30 HC), closely matched for age and gender, were scanned using 3T functional magnetic resonance imaging (fMRI) acquired at resting state. Correlations of low-frequency blood oxygen level dependent signal fluctuations for six previously described striatal subregions were used to obtain connectivity maps of each subregion. Using a factorial design, main effects for differences between groups were obtained and post hoc pairwise group comparisons performed. BPD showed increased connectivity of the dorsal caudal putamen with somatosensory areas such as the insula and temporal gyrus. BPM group showed unique increased connectivity between left dorsal caudate and midbrain regions, as well as increased connectivity between ventral striatum inferior and thalamus. In addition, both BPD and BPM exhibited widespread functional connectivity abnormalities between striatal subregions and frontal cortices, limbic regions, and midbrain structures. In summary, BPD exhibited connectivity abnormalities of associative and somatosensory subregions of the putamen, while BPM exhibited connectivity abnormalities of associative and limbic caudate. Most other striatal subregion connectivity abnormalities were common to both groups and may be trait related. PMID:26824737

  7. Optics measurement and correction for the Relativistic Heavy Ion Collider

    NASA Astrophysics Data System (ADS)

    Shen, Xiaozhe

    The quality of beam optics is of great importance for the performance of a high energy accelerator like the Relativistic Heavy Ion Collider (RHIC). The turn-by-turn (TBT) beam position monitor (BPM) data can be used to derive beam optics. However, the accuracy of the derived beam optics is often limited by the performance and imperfections of instruments as well as measurement methods and conditions. Therefore, a robust and model-independent data analysis method is highly desired to extract noise-free information from TBT BPM data. As a robust signal-processing technique, an independent component analysis (ICA) algorithm called second order blind identification (SOBI) has been proven to be particularly efficient in extracting physical beam signals from TBT BPM data even in the presence of instrument's noise and error. We applied the SOBI ICA algorithm to RHIC during the 2013 polarized proton operation to extract accurate linear optics from TBT BPM data of AC dipole driven coherent beam oscillation. From the same data, a first systematic estimation of RHIC BPM noise performance was also obtained by the SOBI ICA algorithm, and showed a good agreement with the RHIC BPM configurations. Based on the accurate linear optics measurement, a beta-beat response matrix correction method and a scheme of using horizontal closed orbit bumps at sextupoles for arc beta-beat correction were successfully applied to reach a record-low beam optics error at RHIC. This thesis presents principles of the SOBI ICA algorithm and theory as well as experimental results of optics measurement and correction at RHIC.

  8. Preoperative risk assessment among women undergoing bilateral prophylactic mastectomy for cancer risk reduction.

    PubMed

    Rueth, Natasha M; McMahon, Melissa; Arrington, Amanda K; Swenson, Karen; Leach, Joseph; Tuttle, Todd M

    2011-09-01

    Cancer risk assessment is an important decision-making tool for women considering irreversible risk-reducing surgery. Our objective was to determine the prevalence of BRCA testing among women undergoing bilateral prophylactic mastectomy (BPM) and to review the characteristics of women who choose BPM within a metropolitan setting. We retrospectively reviewed records of women who underwent BPM in the absence of cancer within 2 health care systems that included 5 metropolitan hospitals. Women with invasive carcinoma or ductal carcinoma in situ (DCIS) were excluded; neither lobular carcinoma in situ (LCIS) nor atypical hyperplasia (AH) were exclusion criteria. We collected demographic information and preoperative screening and risk assessment, BRCA testing, reconstruction, and associated cancer risk-reducing surgery data. We compared women who underwent BRCA testing to those not tested. From January 2002 to July 2009, a total of 71 BPMs were performed. Only 25 women (35.2%) had preoperative BRCA testing; 88% had a BRCA mutation. Compared with tested women, BRCA nontested women were significantly older (39.1 vs. 49.2 years, P < 0.001), had significantly more preoperative biopsies and mammograms and had fewer previous or simultaneous cancer risk-reducing surgery (oophorectomy). Among BRCA nontested women, common indications for BPM were family history of breast cancer (n = 21, 45.6%) or LCIS or AH (n = 16, 34.8%); 9 nontested women (19.6%) chose BPM based on exclusively on cancer-risk anxiety or personal preference. Most women who underwent BPM did not receive preoperative genetic testing. Further studies are needed to corroborate our findings in other geographic regions and practice settings.

  9. Heart rate differentiates urgency and emergency in hypertensive crisis.

    PubMed

    Al Bannay, Rashed; Böhm, Michael; Husain, Aysha

    2013-08-01

    To study the clinical significance of presenting blood pressure parameters and heart rate in patients with hypertensive crisis. In patients admitted with hypertensive crisis between January 2011 and May 2011, demography, mode of presentation, co-morbidities, blood pressure readings, and heart rate at presentation were documented. Further clustering of hypertensive crisis into emergency or urgency was based on the presence or absence of target organ involvement. The relationship between blood pressure parameters, heart rate, and other variables was analyzed. 189 patients in sinus rhythm were enrolled in this pilot study. The rate of hypertensive urgency was 56 %, whereas the rate of hypertensive emergency was 44 %, respectively. Subjects with hypertensive emergency had a higher mean heart rate (93 ± 22.7 bpm) than those with urgency (81 ± 11.5 bpm) (P = 0.015). Women had higher heart rates (92 ± 18.5 bpm) than men (86 ± 17.6 bpm) (P = 0.014). Heart rates below 100 bpm had a specificity of 94 %, classifying patients as hypertensive urgency. Tachycardia had a powerful statistical association with hypertensive left ventricular failure (P < 0.0001). Other hemodynamic parameters, including systolic blood pressure, diastolic blood pressure, pulse pressure, and mean blood pressure relates neither to urgency nor to emergency. Diabetic patients with HBA1c levels of more than 53 mmol/mol had a heart rate of more than 100 bpm (P = 0.015) during hypertensive crisis. Normal heart rate is characteristic of hypertensive urgency. Tachycardia in this setting is an ominous sign and denotes hypertensive complications in particular left ventricular failure. Among diabetics, elevated heart rate is associated with poor glycemic control.

  10. Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

    NASA Astrophysics Data System (ADS)

    Lee, S. H.; Yang, B. X.; Collins, J. T.; Ramanathan, M.

    2017-02-01

    Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This paper presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

  11. Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade.

    PubMed

    Lee, S H; Yang, B X; Collins, J T; Ramanathan, M

    2017-02-01

    Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs), which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This paper presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.

  12. First Results From the (Multibeam) Hydrosweep DS2 Upgrade on the R/V Maurice Ewing

    NASA Astrophysics Data System (ADS)

    Chayes, D. N.; Slagle, A.; Caress, D. W.; Arko, R. A.

    2001-12-01

    The ATLAS Hydrosweep DS multibeam swath mapping sonar system on the R/V Maurice Ewing was upgraded to a DS2 in May 2000. This upgrade increased the effective swath width from 59 beams over about 89 degrees to as many as 140 beams over approximately 118 degrees, added sidescan image as well as data records from which backscatter can be extracted. The upgrade replaced the outdated processing computer, half-inch tape drive and console with modern workstations and 4mm tape. The upgrade did not require changes to the under hull transducer arrays or transceivers so it was relatively inexpensive and was accomplished in a few days during a transit of the Panama Canal. Evaluation and software enhancements were done during subsequent transits. MB-System was enhanced to support the native, raw data format of the Hydrosweep DS2. We also expect to be able to support the more general SURF format that is also generated by new ATLAS sonar systems in the near future. In addition to the hardware and software upgrades to the multibeam, we installed a POS/MV-320 vertical reference system to take over from our venerable HIPPY-120 as the primary attitude reference for the Hydrosweep on the Ewing. The attitude data from the POS has allowed us to eliminate the turn rate restrictions and to improve the data quality. As an additional benefit the P-Code aided position data produced by the POS is significantly more stable and better behaved than our other navigation sources. The upgraded sonar was used during EW0108 (Taylor) in the Gulf of Corinth. As is usually the case with new implementations or modifications of complex systems, some unexpected behaviors were observed and carefully documented. Good remote support from the manufacturer enabled us to implement fixes and to generate very good quality bathymetry and sidescan images on board and in shore-side post processing. Two related software prototypes are currently being evaluated as part of this upgrade package. One is a web-based real-time watch standers logbook that facilitates the entry of standard log information directly into a relational database (rather than by hand on paper forms.) The second is a relational database that contains the FGDC metadata for multibeam swath bathymetry. This initial upgrade to our Hydrosweep establishes a stable base from which we expect to evolve significant new capabilities in the future. Some of these capabilities will be based on the unique cross fan capabilities of the Hydrosweep design.

  13. The Tail of BPM

    NASA Astrophysics Data System (ADS)

    Kruba, Steve; Meyer, Jim

    Business process management suites (BPMS's) represent one of the fastest growing segments in the software industry as organizations automate their key business processes. As this market matures, it is interesting to compare it to Chris Anderson's 'Long Tail.' Although the 2004 "Long Tail" article in Wired magazine was primarily about the media and entertainment industries, it has since been applied (and perhaps misapplied) to other markets. Analysts describe a "Tail of BPM" market that is, perhaps, several times larger than the traditional BPMS product market. This paper will draw comparisons between the concepts in Anderson's article (and subsequent book) and the BPM solutions market.

  14. Coupled optics reconstruction from TBT data using MAD-X

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alexahin, Y.; Gianfelice-Wendt, E.; /Fermilab

    2007-06-01

    Turn-by-turn BPM data provide immediate information on the coupled optics functions at BPM locations. In the case of small deviations from the known (design) uncoupled optics some cognizance of the sources of perturbation, BPM calibration errors and tilts can also be inferred without detailed lattice modeling. In practical situations, however, fitting the lattice model with the help of some optics code would lead to more reliable results. We present an algorithm for coupled optics reconstruction from TBT data on the basis of MAD-X and give examples of its application for the Fermilab Tevatron accelerator.

  15. Performance Evaluation of LDPC Coding and Iterative Decoding System in BPM R/W Channel Affected by Head Field Gradient, Media SFD and Demagnetization Field

    NASA Astrophysics Data System (ADS)

    Nakamura, Yasuaki; Okamoto, Yoshihiro; Osawa, Hisashi; Aoi, Hajime; Muraoka, Hiroaki

    We evaluate the performance of the write-margin for the low-density parity-check (LDPC) coding and iterative decoding system in the bit-patterned media (BPM) R/W channel affected by the write-head field gradient, the media switching field distribution (SFD), the demagnetization field from adjacent islands and the island position deviation. It is clarified that the LDPC coding and iterative decoding system in R/W channel using BPM at 3 Tbit/inch2 has a write-margin of about 20%.

  16. Some Solved Problems with the SLAC PEP-II B-Factory Beam-Position Monitor System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, Ronald G.

    2000-05-05

    The Beam-Position Monitor (BPM) system for the SLAC PEP-II B-Factory has been in operation for over two years. Although the BPM system has met all of its specifications, several problems with the system have been identified and solved. The problems include errors and limitations in both the hardware and software. Solutions of such problems have led to improved performance and reliability. In this paper the authors report on this experience. The process of identifying problems is not at an end and they expect continued improvement of the BPM system.

  17. Development of BPM Electronics at the JLAB FEL

    NASA Astrophysics Data System (ADS)

    Sexton, D.; Evtushenko, P.; Jordan, K.; Yan, J.; Dutton, S.; Moore, W.; Evans, R.; Coleman, J.

    2006-11-01

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with a 74.85 MHz micropulse frequency. For diagnostic reasons and for machine tune up, the micropulse frequency can be reduced to 1.17 MHz, which corresponds to about 160 μA of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 μm is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.

  18. Development of BPM Electronics at the JLAB FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sexton, D.; Evtushenko, P.; Jordan, K.

    2006-11-20

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with a 74.85 MHz micropulse frequency. For diagnostic reasons and for machine tune up, the micropulse frequency can be reducedmore » to 1.17 MHz, which corresponds to about 160 {mu}A of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 {mu}m is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.« less

  19. Development of BPM Electronics at the JLAB FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daniel Sexton; Pavel Evtushenko; Kevin Jordan

    2006-05-01

    A new version of BPM electronics based on the AD8362 RMS detector, which is a direct RF to DC converter, is under development at the JLAB FEL. Each of these new BPM electronics utilizes an embedded ColdFire Microprocessor for data processing and communication with the EPICS control system via TCP/IP. The ColdFire runs RTEMS, which is an open source real-time operating system. The JLAB FEL is a SRF Energy Recovery LINAC capable of running up to 10 mA CW beam with the micropulse up to 74.85 MHz. For diagnostic reasons and for the machine tune up, the micropulse frequency canmore » be reduced to 1.17 MHz, which corresponds to about 160 ?A of beam current. It is required that the BPM system would be functional for all micropulse frequencies. By taking into account the headroom for the beam steering and current variations the dynamic range of the RF front end is required to be about 60 dB. A BPM resolution of at least 100 ?m is required, whereas better resolution is very desirable to make it possible for more accurate measurements of the electron beam optics. Some results of the RF front end development are presented as well as the first measurements made with an electron beam.« less

  20. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  1. Extracellular matrices for gastrointestinal surgery: Ex vivo testing and current applications

    PubMed Central

    Hoeppner, Jens; Marjanovic, Goran; Helwig, Peter; Hopt, Ulrich Theodor; Keck, Tobias

    2010-01-01

    AIM: To assess the effects of bile and pancreatic juice on structural and mechanical resistance of extracellular matrices (ECMs) in vitro. METHODS: Small-intestinal submucosa (SIS), porcine dermal matrix (PDM), porcine pericardial matrix (PPM) and bovine pericardial matrix (BPM) were incubated in human bile and pancreatic juice in vitro. ECMs were examined by macroscopic observation, scanning electron microscopy (SEM) and testing of mechanical resistance. RESULTS: PDM dissolved within 4 d after exposure to bile or pancreatic juice. SIS, PPM and PDM retained their integrity for > 60 d when incubated in either digestive juice. The effect of bile was found to be far more detrimental to mechanical stability than pancreatic juice in all tested materials. In SIS, the loss of mechanical stability after incubation in either of the digestive secretions was less distinct than in PPM and BPM [mFmax 4.01/14.27 N (SIS) vs 2.08/5.23 N (PPM) vs 1.48/7.89 N (BPM)]. In SIS, the extent of structural damage revealed by SEM was more evident in bile than in pancreatic juice. In PPM and BPM, structural damage was comparable in both media. CONCLUSION: PDM is less suitable for support of gastrointestinal healing. Besides SIS, PPM and BPM should also be evaluated experimentally for gastrointestinal indications. PMID:20731016

  2. Effect of varying heart rate on intra-ventricular filling fluid dynamics

    NASA Astrophysics Data System (ADS)

    Santhanakrishnan, Arvind; Okafor, Ikechukwu; Angirish, Yagna; Yoganathan, Ajit

    2013-11-01

    Impaired exercise tolerance is used to delineate asymptomatic patients during the clinical diagnosis of diastolic left heart failure. Examining the effects of varying heart rate on intra-ventricular filling can provide a physical understanding of the specific flow characteristics that are impacted during exercise. In this study, diastolic filling was investigated with an anatomical left ventricle (LV) physical model under normal heart rate of 70 bpm, and varying exercise conditions of 100 bpm and 120 bpm. The LV model was incorporated into a flow loop and tuned for physiological inflow rates and outflow pressures. 2D PIV measurements were conducted along 3 parallel longitudinal planes. The systemic pressure was maintained the same across all test conditions. The E/A ratio was maintained within 1.0-1.2 across all heart rates. The strength of the mitral vortex ring formed during E-wave, as well as the peak incoming jet velocity, decreased with increasing heart rate. During peak flow of the A-wave, the vortex ring propagated farther into the LV for 120 bpm as compared to 70 bpm. The results point to the heightened role of the atrial kick for optimal LV filling during exercise conditions. This study was funded by a grant from the National Heart, Lung and Blood Institute (RO1HL70262).

  3. Ligand effects on the structure and magnetic properties of alternating copper(II) chains with 2,2'-bipyrimidine- and polymethyl-substituted pyrazolates as bridging ligands.

    PubMed

    Castro, Isabel; Calatayud, M Luisa; Barros, Wdeson P; Carranza, José; Julve, Miguel; Lloret, Francesc; Marino, Nadia; De Munno, Giovanni

    2014-06-02

    A novel series of heteroleptic copper(II) compounds of formulas {[Cu2(μ-H2O)(μ-pz)2(μ-bpm)(ClO4)(H2O)]ClO4·2H2O}n (1), {[Cu2(μ-H2O)(μ-3-Mepz)2(μ-bpm)](ClO4)2·2H2O}n (2), and {[Cu2(μ-OH)(μ-3,5-Me2pz)(μ-bpm)(H-3,5-Me2pz)2](ClO4)2}n (3) [bpm = 2,2'-bipyrimidine, Hpz = pyrazole, H-3-Mepz = 3-methylpyrazole, and H-3,5-Me2pz = 3,5-dimethylpyrazole] have been synthesized and structurally characterized by X-ray diffraction methods. The crystal structures of 1 and 2 consist of copper(II) chains with regular alternating bpm and bis(pyrazolate)(aqua) bridges, whereas that of 3 is made up of copper(II) chains with regular alternating bpm and (pyrazolate)(hydroxo) bridges. The copper centers are six- (1) or five-coordinate (2) in axially elongated, octahedral (1) or square-pyramidal (2) environments in 1 and 2, whereas they are five-coordinate in distorted trigonal-bipyramidal surroundings in 3. The values of the copper-copper separations across the bpm/pyrazolate bridges are 5.5442(7)/3.3131(6) (1), 5.538(1)/3.235(1) (2), and 5.7673(7)/3.3220(6) Å (3). The magnetic properties of 1-3 have been investigated in the temperature range of 25-300 K. The analysis of their magnetic susceptibility data through the isotropic Hamiltonian for an alternating antiferromagnetic copper(II) chain model [H = -J∑i=1-n/2 (S2i·S2i-1 + αS2i·S2i+1), with α = J'/J and Si = SCu = 1/2] reveals the presence of a strong to moderate antiferromagnetic coupling through the bis(pyrazolate)(aqua) [-J = 217 (1) and 215 cm(-1) (2)] and (pyrazolate)(hydroxo) bridges [-J = 153 cm(-1) (3)], respectively, whereas a strong to weak antiferromagnetic coupling occurs through the bis-bidentate bpm [-J' = 211 (1), 213 (2), and 44 cm(-1) (3)]. A simple orbital analysis of the magnetic exchange interaction within the bpm- and pyrazolate-bridged dicopper(II) fragments of 1-3 visualizes the σ-type pathways involving the (dx(2)-y(2)) (1 and 2) or d(z(2)) (3) magnetic orbitals on each metal ion, which account for the variation of the magnetic properties in these three novel examples of one-dimensional copper(II) compounds with regular alternating intrachain antiferromagnetic interactions.

  4. Alternative glues for the production of ATLAS silicon strip modules for the Phase-II upgrade of the ATLAS Inner Detector

    NASA Astrophysics Data System (ADS)

    Poley, L.; Bloch, I.; Edwards, S.; Friedrich, C.; Gregor, I.-M.; Jones, T.; Lacker, H.; Pyatt, S.; Rehnisch, L.; Sperlich, D.; Wilson, J.

    2016-05-01

    The Phase-II upgrade of the ATLAS detector for the High Luminosity Large Hadron Collider (HL-LHC) includes the replacement of the current Inner Detector with an all-silicon tracker consisting of pixel and strip detectors. The current Phase-II detector layout requires the construction of 20,000 strip detector modules consisting of sensor, circuit boards and readout chips, which are connected mechanically using adhesives. The adhesive used initially between readout chips and circuit board is a silver epoxy glue as was used in the current ATLAS SemiConductor Tracker (SCT). However, this glue has several disadvantages, which motivated the search for an alternative. This paper presents a study of six ultra-violet (UV) cure glues and a glue pad for possible use in the assembly of silicon strip detector modules for the ATLAS upgrade. Trials were carried out to determine the ease of use, thermal conduction and shear strength. Samples were thermally cycled, radiation hardness and corrosion resistance were also determined. These investigations led to the exclusion of three UV cure glues as well as the glue pad. Three UV cure glues were found to be possible better alternatives than silver loaded glue. Results from electrical tests of first prototype modules constructed using these glues are presented.

  5. The evolution of the Trigger and Data Acquisition System in the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Krasznahorkay, A.; Atlas Collaboration

    2014-06-01

    The ATLAS experiment, aimed at recording the results of LHC proton-proton collisions, is upgrading its Trigger and Data Acquisition (TDAQ) system during the current LHC first long shutdown. The purpose of the upgrade is to add robustness and flexibility to the selection and the conveyance of the physics data, simplify the maintenance of the infrastructure, exploit new technologies and, overall, make ATLAS data-taking capable of dealing with increasing event rates. The TDAQ system used to date is organised in a three-level selection scheme, including a hardware-based first-level trigger and second- and third-level triggers implemented as separate software systems distributed on separate, commodity hardware nodes. While this architecture was successfully operated well beyond the original design goals, the accumulated experience stimulated interest to explore possible evolutions. We will also be upgrading the hardware of the TDAQ system by introducing new elements to it. For the high-level trigger, the current plan is to deploy a single homogeneous system, which merges the execution of the second and third trigger levels, still separated, on a unique hardware node. Prototyping efforts already demonstrated many benefits to the simplified design. In this paper we report on the design and the development status of this new system.

  6. Testbeam results of irradiated ams H18 HV-CMOS pixel sensor prototypes

    NASA Astrophysics Data System (ADS)

    Benoit, M.; Braccini, S.; Casse, G.; Chen, H.; Chen, K.; Di Bello, F. A.; Ferrere, D.; Golling, T.; Gonzalez-Sevilla, S.; Iacobucci, G.; Kiehn, M.; Lanni, F.; Liu, H.; Meng, L.; Merlassino, C.; Miucci, A.; Muenstermann, D.; Nessi, M.; Okawa, H.; Perić, I.; Rimoldi, M.; Ristić, B.; Barrero Pinto, M. Vicente; Vossebeld, J.; Weber, M.; Weston, T.; Wu, W.; Xu, L.; Zaffaroni, E.

    2018-02-01

    HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the 4th generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between 1× 1014 and 5× 1015 1-MeV- neq. The sensors were glued to ATLAS FE-I4 pixel readout chips and measured at the CERN SPS H8 beamline using the FE-I4 beam telescope. Results for all fluences are very encouraging with all hit efficiencies being better than 97% for bias voltages of 85 V. The sample irradiated to a fluence of 1× 1015 neq—a relevant value for a large volume of the upgraded tracker—exhibited 99.7% average hit efficiency. The results give strong evidence for the radiation tolerance of HV-CMOS sensors and their suitability as sensors for the experimental HL-LHC upgrades and future large-area silicon-based tracking detectors in high-radiation environments.

  7. The correlation between fetal bradycardia area in the second stage of labor and acidemia at birth.

    PubMed

    Tranquilli, Andrea L; Biagini, Alessandra; Greco, Pantaleo; Di Tommaso, Mariarosaria; Giannubilo, Stefano R

    2013-09-01

    To quantify fetal bradycardia in the second stage of labor and to determine the threshold of the area that correlates with neonatal acidemia. We analyzed the cardiotocograms of 33 women with single pregnancy and term spontaneous labor who presented fetal bradycardia in the second stage of labor. We retrospectively calculated the fetal bradycardia area in the last 60 min before delivery with an upper limit of 90 bpm and correlated the area with neonatal pH. The study of the regression line determined the cut-off threshold between fetal well-being and distress. Significance was set at p < 0.05. The linear correlation between the bradycardia area and neonatal pH indicate that increasing bradycardia area was correlated with significant pH decrease. The threshold value of the area indicative of severe acidemia was ≥ 12.72 cm(2) (Pearson r = -0.76, p < 0.002). The diagnostic accuracy of the test was 73%. The PPV = 78.5% and the NPV = 68.4%. With such a cut-off, the timing of acidemia can be calculated as 25 min for a fetal heart rate (FHR) of 80 bpm, 13 min for a FHR of 70 bpm, 8 min for a FHR of 60 bpm, 6 min for a FHR of 50 bpm and 5 min for a FHR of 40 bpm. The bradycardia area in the second stage of labor significantly correlates with an accurate timing of fetal acidemia. Regardless of the cause of the bradycardia, the time for intervention is often short, meaning that any available intervention may be ineffective in preventing acidemia or even injury.

  8. Dopamine depletion attenuates some behavioral abnormalities in a hyperdopaminergic mouse model of bipolar disorder

    PubMed Central

    van Enkhuizen, Jordy; Geyer, Mark A.; Halberstadt, Adam L.; Zhuang, Xiaoxi; Young, Jared W.

    2014-01-01

    Background Patients with BD suffer from multifaceted symptoms, including hyperactive and psychomotor agitated behaviors. Previously, we quantified hyperactivity, increased exploration, and straighter movements of patients with BD mania in the human Behavioral Pattern Monitor (BPM). A similar BPM profile is observed in mice that are hyperdopaminergic due to reduced dopamine transporter (DAT) functioning. We hypothesized that dopamine depletion through alpha-methyl-p-tyrosine (AMPT) administration would attenuate this mania-like profile. Methods Male and female DAT wild-type (WT; n=26) and knockdown (KD; n=28) mice on a C57BL/6 background were repeatedly tested in the BPM to assess profile robustness and stability. The optimal AMPT dose was identified by treating male C57BL/6 mice (n=39) with vehicle or AMPT (10, 30, or 100 mg/kg) at 24, 20, and 4 h prior to testing in the BPM. Then, male and female DAT WT (n=40) and KD (n=37) mice were tested in the BPM after vehicle or AMPT (30 mg/kg) treatment. Results Compared to WT littermates, KD mice exhibited increased activity, exploration, straighter movement, and disorganized behavior. AMPT-treatment reduced hyperactivity and increased path organization, but potentiated specific exploration in KD mice without affecting WT mice. Limitations AMPT is not specific to dopamine and also depletes norepinephrine. Conclusions KD mice exhibit abnormal exploration in the BPM similar to patients with BD mania. AMPT-induced dopamine depletion attenuated some, but potentiated other, aspects of this mania-like profile in mice. Future studies should extend these findings into other aspects of mania to determine the suitability of AMPT as a treatment for BD mania. PMID:24287168

  9. BPM-CUL3 E3 ligase modulates thermotolerance by facilitating negative regulatory domain-mediated degradation of DREB2A in Arabidopsis.

    PubMed

    Morimoto, Kyoko; Ohama, Naohiko; Kidokoro, Satoshi; Mizoi, Junya; Takahashi, Fuminori; Todaka, Daisuke; Mogami, Junro; Sato, Hikaru; Qin, Feng; Kim, June-Sik; Fukao, Yoichiro; Fujiwara, Masayuki; Shinozaki, Kazuo; Yamaguchi-Shinozaki, Kazuko

    2017-10-03

    DEHYDRATION-RESPONSIVE ELEMENT BINDING PROTEIN 2A (DREB2A) acts as a key transcription factor in both drought and heat stress tolerance in Arabidopsis and induces the expression of many drought- and heat stress-inducible genes. Although DREB2A expression itself is induced by stress, the posttranslational regulation of DREB2A, including protein stabilization, is required for its transcriptional activity. The deletion of a 30-aa central region of DREB2A known as the negative regulatory domain (NRD) transforms DREB2A into a stable and constitutively active form referred to as DREB2A CA. However, the molecular basis of this stabilization and activation has remained unknown for a decade. Here we identified BTB/POZ AND MATH DOMAIN proteins (BPMs), substrate adaptors of the Cullin3 (CUL3)-based E3 ligase, as DREB2A-interacting proteins. We observed that DREB2A and BPMs interact in the nuclei, and that the NRD of DREB2A is sufficient for its interaction with BPMs. BPM -knockdown plants exhibited increased DREB2A accumulation and induction of DREB2A target genes under heat and drought stress conditions. Genetic analysis indicated that the depletion of BPM expression conferred enhanced thermotolerance via DREB2A stabilization. Thus, the BPM-CUL3 E3 ligase is likely the long-sought factor responsible for NRD-dependent DREB2A degradation. Through the negative regulation of DREB2A stability, BPMs modulate the heat stress response and prevent an adverse effect of excess DREB2A on plant growth. Furthermore, we found the BPM recognition motif in various transcription factors, implying a general contribution of BPM-mediated proteolysis to divergent cellular responses via an accelerated turnover of transcription factors.

  10. Heart rate and use of beta-blockers in stable outpatients with coronary artery disease.

    PubMed

    Steg, Ph Gabriel; Ferrari, Roberto; Ford, Ian; Greenlaw, Nicola; Tardif, Jean-Claude; Tendera, Michal; Abergel, Hélène; Fox, Kim M

    2012-01-01

    Heart rate (HR) is an emerging risk factor in coronary artery disease (CAD). However, there is little contemporary data regarding HR and the use of HR-lowering medications, particularly beta-blockers, among patients with stable CAD in routine clinical practice. The goal of the present analysis was to describe HR in such patients, overall and in relation to beta-blocker use, and to describe the determinants of HR. CLARIFY is an international, prospective, observational, longitudinal registry of outpatients with stable CAD, defined as prior myocardial infarction or revascularization procedure, evidence of coronary stenosis of >50%, or chest pain associated with proven myocardial ischemia. A total of 33,438 patients from 45 countries in Europe, the Americas, Africa, Middle East, and Asia/Pacific were enrolled between November 2009 and July 2010. Most of the 33,177 patients included in this analysis were men (77.5%). Mean (SD) age was 64.2 (10.5) years, HR by pulse was 68.3 (10.6) bpm, and by electrocardiogram was 67.2 (11.4) bpm. Overall, 44.0% had HR ≥ 70 bpm. Beta-blockers were used in 75.1% of patients and another 14.4% had intolerance or contraindications to beta-blocker therapy. Among 24,910 patients on beta-blockers, 41.1% had HR ≥ 70 bpm. HR ≥ 70 bpm was independently associated with higher prevalence and severity of angina, more frequent evidence of myocardial ischemia, and lack of use of HR-lowering agents. Despite a high rate of use of beta-blockers, stable CAD patients often have resting HR ≥ 70 bpm, which was associated with an overall worse health status, more frequent angina and ischemia. Further HR lowering is possible in many patients with CAD. Whether it will improve symptoms and outcomes is being tested.

  11. Automatic exposure control at single- and dual-heartbeat CTCA on a 320-MDCT volume scanner: effect of heart rate, exposure phase window setting, and reconstruction algorithm.

    PubMed

    Funama, Yoshinori; Utsunomiya, Daisuke; Taguchi, Katsuyuki; Oda, Seitaro; Shimonobo, Toshiaki; Yamashita, Yasuyuki

    2014-05-01

    To investigate whether electrocardiogram (ECG)-gated single- and dual-heartbeat computed tomography coronary angiography (CTCA) with automatic exposure control (AEC) yields images with uniform image noise at reduced radiation doses. Using an anthropomorphic chest CT phantom we performed prospectively ECG-gated single- and dual-heartbeat CTCA on a second-generation 320-multidetector CT volume scanner. The exposure phase window was set at 75%, 70-80%, 40-80%, and 0-100% and the heart rate at 60 or 80 or corr80 bpm; images were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR, adaptive iterative dose reduction 3D). We applied AEC and set the image noise level to 20 or 25 HU. For each technique we determined the image noise and the radiation dose to the phantom center. With half-scan reconstruction at 60 bpm, a 70-80% phase window- and a 20-HU standard deviation (SD) setting, the imagenoise level and -variation along the z axis manifested similar curves with FBP and IR. With half-scan reconstruction, the radiation dose to the phantom center with 70-80% phase window was 18.89 and 12.34 mGy for FBP and 4.61 and 3.10 mGy for IR at an SD setting SD of 20 and 25 HU, respectively. At 80 bpm with two-segment reconstruction the dose was approximately twice that of 60 bpm at both SD settings. However, increasing radiation dose at corr80 bpm was suppressed to 1.39 times compared to 60 bpm. AEC at ECG-gated single- and dual-heartbeat CTCA controls the image noise at different radiation dose. Copyright © 2013 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Body image issues after bilateral prophylactic mastectomy with breast reconstruction in healthy women at risk for hereditary breast cancer.

    PubMed

    Gopie, Jessica P; Mureau, Marc A M; Seynaeve, Caroline; Ter Kuile, Moniek M; Menke-Pluymers, Marian B E; Timman, Reinier; Tibben, Aad

    2013-09-01

    The outcome of bilateral prophylactic mastectomy with breast reconstruction (BPM-IBR) in healthy BRCA1/2 mutation carriers can be potentially burdensome for body image and the intimate relationship. Therefore, in the current analysis the impact on body image, sexual and partner relationship satisfaction was prospectively investigated in women opting for BPM-IBR as well as cancer distress and general quality of life. Healthy women undergoing BPM-IBR completed questionnaires preoperatively (T0, n = 48), at 6 months (T1, n = 44) and after finishing breast reconstruction (median 21 months, range 12-35) (T2, n = 36). With multi-level regression analyses the course of outcome variables was investigated and a statistically significant change in body image and/or sexual and partner relationship satisfaction was predicted by baseline covariates. Body image significantly decreased at T1. At T2 sexual relationship satisfaction and body image tended to be lower compared to baseline. The overall partner relationship satisfaction did not significantly change. At T2, 37 % of the women reported that their breasts felt unpleasantly, 29 % was not satisfied with their breast appearance and 21 % felt embarrassed for their naked body. Most body image issues remained unchanged in 30 % of the women. A negative body image was predicted by high preoperative cancer distress. BPM-IBR was associated with adverse impact on body image in a substantial subgroup, but satisfaction with the overall sexual and partner relationship did not significantly change in time. The psychosocial impact of BPM-IBR in unaffected women should not be underestimated. Psychological support should ideally be integrated both before and after BPM-IBR.

  13. Effects of various mouthpieces on respiratory physiology during steady-state exercise in college-aged subjects.

    PubMed

    Garner, Dena P

    2015-01-01

    Protective mouthpieces have been used in a variety of sports to decrease the risk of orofacial injury. There are limited data to suggest that mouthpiece use during exercise may also provide an ergogenic effect. The aim of the present study was to investigate the effects of 3 different mouthpiece designs-boil-and-bite (BB) mouthpiece, ethylene vinyl acetate (EVA) custom mandibular mouthpiece, and polypropylene (Poly) custom mandibular mouthpiece-on respiratory physiology parameters and compare them with results of a no-mouthpiece (NM) condition. Sixteen college-aged, recreationally fit subjects ran for 10 minutes in 4 separate trials; mouthpiece conditions were randomly assigned to each trial for all subjects. Respiratory and cardiorespiratory measures, including oxygen uptake, carbon dioxide exhalation, ventilation, heart rate, tidal volume, and respiratory rate (RR), were assessed throughout testing. A repeated-measures analysis of variance indicated that RR was significantly lower (P = 0.04) in the BB mouthpiece condition (27.92 breaths per minute [BPM]) than in the NM condition (30.63 BPM). In paired t tests between conditions, the RR demonstrated in the BB condition (27.92 BPM) was significantly lower (P = 0.04) than that of each other condition (NM, 30.63 BPM; EVA, 29.92 BPM; and Poly, 29.92 BPM). The outcomes of the present study demonstrate that the use of the BB mouthpiece decreased RR during exercise. The differences cited between conditions may be attributed to the design of the mouthpiece and its mandibular placement as well as the activity of the genioglossus muscle. However, future studies should assess these parameters to determine the plausibility of these theories.

  14. First fabrication of a silicon vertical JFET for power distribution in high energy physics applications

    NASA Astrophysics Data System (ADS)

    Fernández-Martínez, Pablo; Flores, D.; Hidalgo, S.; Quirion, D.; Durà, R.; Ullán, M.

    2018-01-01

    A new vertical JFET transistor has been recently developed at the IMB-CNM, taking advantage of a deep-trenched 3D technology to achieve vertical conduction and low switch-off voltage. The silicon V-JFET transistors were mainly conceived to work as rad-hard protection switches for the renewed HV powering scheme (HV-MUX) of the ATLAS upgraded tracker. This work presents the features of the first batch of V-JFETs produced at the IMB-CNM clean room, together with the results of a full pre-irradiation characterization of the fabricated prototypes. Details of the technological process are provided and the outcome quality is also evaluated with the aid of reverse engineering techniques. Concerning the electrical performance of the prototypes, promising results were obtained, already meeting most of the HV-MUX specifications, both at room and below-zerotemperatures.

  15. SALT, a dedicated readout chip for high precision tracking silicon strip detectors at the LHCb Upgrade

    NASA Astrophysics Data System (ADS)

    Bugiel, Sz.; Dasgupta, R.; Firlej, M.; Fiutowski, T.; Idzik, M.; Kuczynska, M.; Moron, J.; Swientek, K.; Szumlak, T.

    2016-02-01

    The Upstream Tracker (UT) silicon strip detector, one of the central parts of the tracker system of the modernised LHCb experiment, will use a new 128-channel readout ASIC called SALT. It will extract and digitise analogue signals from the UT sensors, perform digital signal processing and transmit a serial output data. The SALT is being designed in CMOS 130 nm process and uses a novel architecture comprising of analog front-end and fast (40 MSps) ultra-low power (<0.5 mW) 6-bit ADC in each channel. The prototype ASICs of important functional blocks, like analogue front-end, 6-bit SAR ADC, PLL, and DLL, were designed, fabricated and tested. A prototype of an 8-channel version of the SALT chip, comprising all important functionalities was also designed and fabricated. The architecture and design of the SALT, together with the selected preliminary tests results, are presented.

  16. Assembly and analysis of a male sterile rubber tree mitochondrial genome reveals DNA rearrangement events and a novel transcript.

    PubMed

    Shearman, Jeremy R; Sangsrakru, Duangjai; Ruang-Areerate, Panthita; Sonthirod, Chutima; Uthaipaisanwong, Pichahpuk; Yoocha, Thippawan; Poopear, Supannee; Theerawattanasuk, Kanikar; Tragoonrung, Somvong; Tangphatsornruang, Sithichoke

    2014-02-10

    The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility.

  17. Analytical N beam position monitor method

    NASA Astrophysics Data System (ADS)

    Wegscheider, A.; Langner, A.; Tomás, R.; Franchi, A.

    2017-11-01

    Measurement and correction of focusing errors is of great importance for performance and machine protection of circular accelerators. Furthermore LHC needs to provide equal luminosities to the experiments ATLAS and CMS. High demands are also set on the speed of the optics commissioning, as the foreseen operation with β*-leveling on luminosity will require many operational optics. A fast measurement of the β -function around a storage ring is usually done by using the measured phase advance between three consecutive beam position monitors (BPMs). A recent extension of this established technique, called the N-BPM method, was successfully applied for optics measurements at CERN, ALBA, and ESRF. We present here an improved algorithm that uses analytical calculations for both random and systematic errors and takes into account the presence of quadrupole, sextupole, and BPM misalignments, in addition to quadrupolar field errors. This new scheme, called the analytical N-BPM method, is much faster, further improves the measurement accuracy, and is applicable to very pushed beam optics where the existing numerical N-BPM method tends to fail.

  18. Digital signal processing the Tevatron BPM signals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cancelo, G.; James, E.; Wolbers, S.

    2005-05-01

    The Beam Position Monitor (TeV BPM) readout system at Fermilab's Tevatron has been updated and is currently being commissioned. The new BPMs use new analog and digital hardware to achieve better beam position measurement resolution. The new system reads signals from both ends of the existing directional stripline pickups to provide simultaneous proton and antiproton measurements. The signals provided by the two ends of the BPM pickups are processed by analog band-pass filters and sampled by 14-bit ADCs at 74.3MHz. A crucial part of this work has been the design of digital filters that process the signal. This paper describesmore » the digital processing and estimation techniques used to optimize the beam position measurement. The BPM electronics must operate in narrow-band and wide-band modes to enable measurements of closed-orbit and turn-by-turn positions. The filtering and timing conditions of the signals are tuned accordingly for the operational modes. The analysis and the optimized result for each mode are presented.« less

  19. MEthods of ASsessing blood pressUre: identifying thReshold and target valuEs (MeasureBP): a review & study protocol.

    PubMed

    Blom, Kimberly C; Farina, Sasha; Gomez, Yessica-Haydee; Campbell, Norm R C; Hemmelgarn, Brenda R; Cloutier, Lyne; McKay, Donald W; Dawes, Martin; Tobe, Sheldon W; Bolli, Peter; Gelfer, Mark; McLean, Donna; Bartlett, Gillian; Joseph, Lawrence; Featherstone, Robin; Schiffrin, Ernesto L; Daskalopoulou, Stella S

    2015-04-01

    Despite progress in automated blood pressure measurement (BPM) technology, there is limited research linking hard outcomes to automated office BPM (OBPM) treatment targets and thresholds. Equivalences for automated BPM devices have been estimated from approximations of standardized manual measurements of 140/90 mmHg. Until outcome-driven targets and thresholds become available for automated measurement methods, deriving evidence-based equivalences between automated methods and standardized manual OBPM is the next best solution. The MeasureBP study group was initiated by the Canadian Hypertension Education Program to close this critical knowledge gap. MeasureBP aims to define evidence-based equivalent values between standardized manual OBPM and automated BPM methods by synthesizing available evidence using a systematic review and individual subject-level data meta-analyses. This manuscript provides a review of the literature and MeasureBP study protocol. These results will lay the evidenced-based foundation to resolve uncertainties within blood pressure guidelines which, in turn, will improve the management of hypertension.

  20. Ventricular fibrillation occurring after atrioventricular node ablation despite minimal difference between pre- and post-ablation heart rates.

    PubMed

    Squara, F; Theodore, G; Scarlatti, D; Ferrari, E

    2017-02-01

    We report the case of an 82-year-old man presenting with ventricular fibrillation (VF) occurring acutely after atrioventricular node (AVN) ablation. This patient had severe valvular cardiomyopathy, chronic atrial fibrillation (AF), and underwent prior to the AVN ablation a biventricular implantable cardiac defibrillator positioning. The VF was successfully cardioverted with one external electrical shock. What makes this presentation original is that the pre-ablation spontaneous heart rate in AF was slow (84 bpm), and that VF occurred after ablation despite a minimal heart rate drop of only 14 bpm. VF is the most feared complication of AVN ablation, but it had previously only been described in case of acute heart rate drop after ablation of at least 30 bpm (and more frequently>50 bpm). This case report highlights the fact that VF may occur after AVN ablation regardless of the heart rate drop, rendering temporary fast ventricular pacing mandatory whatever the pre-ablation heart rate. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  1. Design of T-GEM detectors for X-ray diagnostics on JET

    NASA Astrophysics Data System (ADS)

    Rzadkiewicz, J.; Dominik, W.; Scholz, M.; Chernyshova, M.; Czarski, T.; Czyrkowski, H.; Dabrowski, R.; Jakubowska, K.; Karpinski, L.; Kasprowicz, G.; Kierzkowski, K.; Pozniak, K.; Salapa, Z.; Zabolotny, W.; Blanchard, P.; Tyrrell, S.; Zastrow, K.-D.; JET EFDA Contributors

    2013-08-01

    Upgraded high-resolution X-ray diagnostics on JET is expected to monitor the plasma radiation emitted by W46+ and Ni26+ ions at 2.4 keV and 7.8 keV photon energies, respectively. Both X-ray lines will be monitored by new generation energy-resolved micropattern gas detectors with 1-D position reconstruction capability. The detection structure is based on triple GEM (T-GEM) amplification structure followed by the strip readout electrode. This article presents a design of new detectors and prototype detector tests.

  2. Update on optical design of adaptive optics system at Lick Observatory

    NASA Astrophysics Data System (ADS)

    Bauman, Brian J.; Gavel, Donald T.; Waltjen, Kenneth E.; Freeze, Gary J.; Hurd, Randall L.; Gates, Elinor L.; Max, Claire E.; Olivier, Scot S.; Pennington, Deanna M.

    2002-02-01

    In 1999, we presented our plan to upgrade the adaptive optics (AO) system on the Lick Observatory Shane telescope (3m) from a prototype instrument pressed into field service to a facility instrument. This paper updates the progress of that plan and details several important improvements in the alignment and calibration of the AO bench. The paper also includes a discussion of the problems seen in the original design of the tip/tilt (t/t) sensor used in laser guide star mode, and how these problems were corrected with excellent results.

  3. Update on Optical Design of Adaptive Optics System at Lick Observatory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauman, B J; Gavel, D T; Waltjen, K E

    2001-07-31

    In 1999, we presented our plan to upgrade the adaptive optics (AO) system on the Lick Observatory Shane telescope (3m) from a prototype instrument pressed into field service to a facility instrument. This paper updates the progress of that plan and details several important improvements in the alignment and calibration of the AO bench. The paper also includes a discussion of the problems seen in the original design of the tip/tilt (t/t) sensor used in laser guide star mode, and how these problems were corrected with excellent results.

  4. Intraosseous Hydroxocobalamin versus Intravenous Hydroxocobalamin Compared to Intraosseous Whole Blood or No Treatment for Hemorrhagic Shock in a Swine Model

    DTIC Science & Technology

    2016-05-02

    MAP significantly improved over time in both treated groups but not in the control group. By 60 minutes, mean HR was 116 and 135 bpm and MAP was 60...and 65 mm Hg for IV and IO HOC groups (not significantly different) whereas non-treated animals displayed a mean HR of 157 bpm and MAP of 43 mm Hg...group. By 60 minutes, mean HR was 116(9.9) and 100(11.2) bpm and MAP was 57(3.9) and 62(4.4) mm Hg for IV HOC and WB groups (not significantly

  5. Modifying middle school physical education: piloting strategies to increase physical activity.

    PubMed

    Jago, Russell; McMurray, Robert G; Bassin, Stanley; Pyle, Laura; Bruecker, Steve; Jakicic, John M; Moe, Esther; Murray, Tinker; Volpe, Stella L

    2009-05-01

    Two pilot studies were conducted to examine whether 6th grade students can achieve moderate to vigorous physical activity (MVPA) from 1) activity-based physical education (AB-PE) with 585 participants and 2) a curricular-based (CB-PE) program with 1,544 participants and randomly sampled heart rates during lessons. AB-PE participants spent between 54-66% with a heart rate >140 bpm. CB-PE participants spent between 49-58% with a heart rate >140 bpm. Girls' mean heart rate was 3.7 bpm lower than the boys. PE can be readily modified so that students spend more than 50% of time in MVPA.

  6. Modifying Middle School Physical Education: Piloting Strategies to Increase Physical Activity

    PubMed Central

    Jago, Russell; McMurray, Robert G.; Bassin, Stanley; Pyle, Laura; Bruecker, Steve; Jakicic, John M.; Moe, Esther; Murray, Tinker; Volpe, Stella L.

    2009-01-01

    Two pilot studies were conducted to examine whether 6th grade students can achieve moderate to vigorous physical activity (MVPA) from 1) activity-based physical education (AB-PE) with 585 participants and 2) a curricular-based (CB-PE) program with 1,544 participants and randomly sampled heart rates during lessons. AB-PE participants spent between 54-66% with a heart rate >140 bpm. CB-PE participants spent between 49-58% with a heart rate >140 bpm. Girls' mean heart rate was 3.7 bpm lower than the boys. PE can be readily modified so that students spend more than 50% of time in MVPA. PMID:19556623

  7. Single-pass BPM system of the Photon Factory storage ring.

    PubMed

    Honda, T; Katoh, M; Mitsuhashi, T; Ueda, A; Tadano, M; Kobayashi, Y

    1998-05-01

    At the 2.5 GeV ring of the Photon Factory, a single-pass beam-position monitor (BPM) system is being prepared for the storage ring and the beam transport line. In the storage ring, the injected beam position during the first several turns can be measured with a single injection pulse. The BPM system has an adequate performance, useful for the commissioning of the new low-emittance lattice. Several stripline BPMs are being installed in the beam transport line. The continuous monitoring of the orbit in the beam transport line will be useful for the stabilization of the injection energy as well as the injection beam orbit.

  8. CEBAF Upgrade Cryomodule Component Testing in the Horizontal Test Bed (HTB)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    I.E. Campisi; B. Carpenter; G.K. Davis

    2001-06-01

    The planned upgrade of the CEBAF electron accelerator includes the development of an improved cryomodule. Several components differ substantially from the original CEBAF cryomodule; these include: the new 7-cell, 1.5 GHz cavities with integral helium vessel, a new, backlash-free cavity tuner, the waveguide coupler with its room-temperature ceramic window, and the HOM damping filters. In order to test the design features and performance of the new components, a horizontal cryostat (Horizontal Test Bed) has been constructed which allows testing with a turn around time of less than three weeks. This cryostat provides the environment for testing one or two cavities,more » with associated auxiliary components, in a condition similar to that of a real cryomodule. A series of tests has been performed on a prototype 7-cell cavity and the above-mentioned systems. In this paper the results of the tests on the cryostat, on the cavity performance, on its coupler, on the tuner characteristics, and on the microphonics behavior will be reported.« less

  9. Magnetic Measurements of Storage Ring Magnets for the APS Upgrade Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doose, C.; Dejus, R.; Jaski, M.

    2017-06-01

    Extensive prototyping of storage ring magnets is ongoing at the Advanced Photon Source (APS) in support of the APS Multi-Bend Achromat (MBA) upgrade project (APS-U) [1]. As part of the R&D activities four quadrupole magnets with slightly different geometries and pole tip materials, and one sextupole magnet with vanadium permendur (VP) pole tips were designed, built and tested. Magnets were measured individually using a rotating coil and a Hall probe for detailed mapping of the magnetic field. Magnets were then assembled and aligned relative to each other on a steel support plate and concrete plinth using precision machined surfaces tomore » gain experience with the alignment method chosen for the APS-U storage ring magnets. The required alignment of magnets on a common support structure is 30 μm rms. Measurements of magnetic field quality, strength and magnet alignment after subjecting the magnets and assemblies to different tests are presented.« less

  10. Nuclear Thermal Rocket Element Environmental Simulator (NTREES) Phase II Upgrade Activities

    NASA Technical Reports Server (NTRS)

    Emrich, William J.; Moran, Robert P.; Pearson, J. Bose

    2013-01-01

    To support the on-going nuclear thermal propulsion effort, a state-of-the-art non nuclear experimental test setup has been constructed to evaluate the performance characteristics of candidate fuel element materials and geometries in representative environments. The facility to perform this testing is referred to as the Nuclear Thermal Rocket Element Environment Simulator (NTREES). This device can simulate the environmental conditions (minus the radiation) to which nuclear rocket fuel components will be subjected during reactor operation. Test articles mounted in the simulator are inductively heated in such a manner so as to accurately reproduce the temperatures and heat fluxes which would normally occur as a result of nuclear fission and would be exposed to flowing hydrogen. Initial testing of a somewhat prototypical fuel element has been successfully performed in NTREES and the facility has now been shutdown to allow for an extensive reconfiguration of the facility which will result in a significant upgrade in its capabilities. Keywords: Nuclear Thermal Propulsion, Simulator

  11. Effect of TE Mode Power on the PEP II LER BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ng, Cho-K

    2011-08-26

    The beam chamber of the PEP-II B-Factory Low Energy Ring (LER) arc sections is connected to an antechamber for the absorption of synchrotron radiation on discrete photon stops. The presence of the antechamber substantially reduces the cutoff frequency of the vacuum chamber and, in particular, allows the propagation of higher-order-mode (HOM) TE power generated by beamline components at the BPM signal processing frequency. Calculations of the transmission properties of the TE mode in different sections of the vacuum chamber show that the power is trapped between widely separated bellows in the arc sections. Because of the narrow signal bandwidth andmore » weak coupling of the TE mode to the BPM buttons, the noise contributed by the HOM TE power will not produce a noticeable effect on the BPM position signal voltage. The LER arc vacuum chamber employs an antechamber with a discrete photon stop for absorption of synchrotron radiation and with pumps for maintaining pressure below 10 nTorr [1]. The horizontal dimensions of the antechambers at the pumping chamber section and the magnet chamber section are larger or comparable to that of the beam chamber. Because of the increase in the horizontal dimension, the cutoff frequency of the TE10-like mode (in rectangular coordinates) of the vacuum chamber is considerably reduced and, in particular, is less than the BPM signal processing frequency at 952 MHz. TE power propagating in the vacuum chamber will penetrate through the BPM buttons and will affect the pickup signal if its magnitude is not properly controlled. It is the purpose of this note to clarify various issues pertaining to this problem. TE power is generated when the beam passes a noncylindrically symmetric beamline component such as the RF cavity, the injection region, the IR crotch and the IP region. The beampipes connected to these components have TE cutoff frequencies greater than 952 MHz (for example, the TE cutoff frequency of the RF cavity beampipe is 1.8 GHz), and hence no TE power at this frequency propagates from the component. TE power can also be generated by the scattering of TM power through these beamline components. Since the cutoff frequency of the TM mode is in general higher than that of the TE mode, this mechanism is not pertinent to the problem related to the BPM signal. Consequently, the TE power that needs to be considered is mainly generated by components of the LER arc vacuum chamber, where the TE cutoff frequency is less than the BPM processing frequency.« less

  12. Applications Where Snap is BPM for Radioactive Waste Assay

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, T.J.

    2008-07-01

    Historically, the Atomic Weapons Establishment (AWE) at Aldermaston in the United Kingdom (UK), has used a variety of assay techniques to measure the radioactive content of a diverse range of waste packages from decommissioning, operational and legacy sources. The regulator, the Environment Agency in the UK, places conditions and limits on AWE through an authorisation within the Radioactive Substances Act (RSA93). The conditions and limits require Best Practical Means (BPM) measurements to be used to demonstrate compliance with the authorisation. Hence, the assay technique employed needs to achieve a balance between risk of exposure, environmental considerations, technological considerations, health andmore » safety considerations and cost effectiveness, without being grossly disproportionate in terms of money, time or trouble. Recently published work has concluded that the Spectral Non-destructive Assay Platform (SNAP) assay system is BPM for Depleted Uranium (DU) waste assay at AWE (1) and low level plutonium in soft drummed waste, HEPA filters and soils (2-4). The purpose of this paper is to highlight other applications where SNAP represents BPM for radioactive waste assay. This has been done by intercomparison studies of SNAP with other assay techniques, such as Segmented Gamma Scanner (SGS) and Passive Neutron Coincidence Counter (PNCC). It has been concluded that, for a large range of waste packages encountered at AWE, SNAP is BPM. (author)« less

  13. Discovering Collaboration and Knowledge Management Practices for the Future Digital Factory

    NASA Astrophysics Data System (ADS)

    Flores, Myrna; Vera, Tomas; Tucci, Christopher

    Recently there has been an explosion of new technologies and tools such as wikis, blogs, tags, Facebook, among many others, that are commonly identified under Web 2.0 and which promise a new digital business ecosystem fed by formal/informal and internal/external relationships and interactions. Although Web 2.0 is very promising to enable such collective knowledge creation, technology by itself is not the only ingredient. It is also required to define the right strategy, governance, culture, processes, training, incentives among others, before implementing such innovative open spaces for collaboration and knowledge sharing. Therefore, the objective of this paper is to present a Knowledge Management (KM) Framework and a Maturity Model developed by a CEMEX and EPFL collaborative research project to discover the AS-IS collaboration practices in CEMEX before the implementation of the SMARTBRICKS Web 2.0 prototype for Business Process Management (BPM), currently under development by the Intelligent Manufacturing Systems (IMS) Swiss Digital Factory (DiFac) project.

  14. Transport and emittance study for 18 GHz superconducting-ECR ion source at RCNP.

    PubMed

    Yorita, T; Hatanaka, K; Fukuda, M; Ueda, H; Kibayashi, M; Morinobu, S; Tamii, A

    2012-02-01

    As the upgrade program of the azimuthally varying field (AVF) cyclotron is at the cyclotron facility of the RCNP, Osaka University for the improvement of the quality, stability, and intensity of accelerated beams, an 18 GHz superconducting (SC) ECR ion source has been installed to increase beam currents and to extend the variety of ions, especially for highly charged heavy ions which can be accelerated by RCNP AVF cyclotron. The production development of several ions such as B, O, N, Ne, Ar, Ni, Kr, and Xe has been performed by Yorita et al. [Rev. Sci. Instrum. 79, 02A311(2008); 81, 02A332 (2010)]. Further studies for the beam transport have been done in order to improve the beam current more for injection of cyclotron. The effect of field leakage of AVF main coil is not negligible and additional steering magnet has been installed and then beam transmission has been improved. The emittance monitor has also been developed for the purpose of investigating correlation between emittance of beam from ECR ion sources and injection efficiency. The monitor consists with BPM82 with rotating wire for fast measurement for efficient study.

  15. Electron Beam Diagnostics Of The JLAB UV FEL

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evtushenko, Pavel; Benson, Stephen; Biallas, George

    2011-03-01

    In this contribution we describe various systems and aspects of the electron beam diagnostics of the JLab UV FEL. The FEL is installed on a new bypass beam line at the existing 10 kW IR Upgrade FEL. Here, we describe a set of the following systems. A combination of OTR and phosphor viewers is used for measurements of the transverse beam profile, transverse emittance, and Twiss parameters. This system is also used for alignment of the optical cavity of the UV oscillator and to ensure the overlap between the electron beam and optical mode in the FEL wiggler. A systemmore » of beam position monitors equipped with log-amp based BPM electronics. Bunch length on the order of 120 fs RMS is measured with the help of a modified Martin-Puplett interferometer. The longitudinal transfer function measurement system is used to set up bunch compression in an optimal way, such that the LINAC RF curvature is compensated using only higher order magnetic elements of the beam transport. This set of diagnostic systems made a significant contribution in achieving first lasing of the FEL after only about 60 hours of beam operation.« less

  16. Enhanced Software for Scheduling Space-Shuttle Processing

    NASA Technical Reports Server (NTRS)

    Barretta, Joseph A.; Johnson, Earl P.; Bierman, Rocky R.; Blanco, Juan; Boaz, Kathleen; Stotz, Lisa A.; Clark, Michael; Lebovitz, George; Lotti, Kenneth J.; Moody, James M.; hide

    2004-01-01

    The Ground Processing Scheduling System (GPSS) computer program is used to develop streamlined schedules for the inspection, repair, and refurbishment of space shuttles at Kennedy Space Center. A scheduling computer program is needed because space-shuttle processing is complex and it is frequently necessary to modify schedules to accommodate unanticipated events, unavailability of specialized personnel, unexpected delays, and the need to repair newly discovered defects. GPSS implements constraint-based scheduling algorithms and provides an interactive scheduling software environment. In response to inputs, GPSS can respond with schedules that are optimized in the sense that they contain minimal violations of constraints while supporting the most effective and efficient utilization of space-shuttle ground processing resources. The present version of GPSS is a product of re-engineering of a prototype version. While the prototype version proved to be valuable and versatile as a scheduling software tool during the first five years, it was characterized by design and algorithmic deficiencies that affected schedule revisions, query capability, task movement, report capability, and overall interface complexity. In addition, the lack of documentation gave rise to difficulties in maintenance and limited both enhanceability and portability. The goal of the GPSS re-engineering project was to upgrade the prototype into a flexible system that supports multiple- flow, multiple-site scheduling and that retains the strengths of the prototype while incorporating improvements in maintainability, enhanceability, and portability.

  17. Translating expert system rules into Ada code with validation and verification

    NASA Technical Reports Server (NTRS)

    Becker, Lee; Duckworth, R. James; Green, Peter; Michalson, Bill; Gosselin, Dave; Nainani, Krishan; Pease, Adam

    1991-01-01

    The purpose of this ongoing research and development program is to develop software tools which enable the rapid development, upgrading, and maintenance of embedded real-time artificial intelligence systems. The goals of this phase of the research were to investigate the feasibility of developing software tools which automatically translate expert system rules into Ada code and develop methods for performing validation and verification testing of the resultant expert system. A prototype system was demonstrated which automatically translated rules from an Air Force expert system was demonstrated which detected errors in the execution of the resultant system. The method and prototype tools for converting AI representations into Ada code by converting the rules into Ada code modules and then linking them with an Activation Framework based run-time environment to form an executable load module are discussed. This method is based upon the use of Evidence Flow Graphs which are a data flow representation for intelligent systems. The development of prototype test generation and evaluation software which was used to test the resultant code is discussed. This testing was performed automatically using Monte-Carlo techniques based upon a constraint based description of the required performance for the system.

  18. Construction and beam-tests of silicon-tungsten prototype modules for the CMS High Granularity Calorimeter for HL-LHC

    NASA Astrophysics Data System (ADS)

    Quast, Thorben

    2018-02-01

    As part of its HL-LHC upgrade program, CMS is developing a High Granularity Calorimeter (HGCAL) to replace the existing endcap calorimeters. The HGCAL will be realised as a sampling calorimeter, including an electromagnetic compartment comprising 28 layers of silicon pad detectors with pad areas of 0.5-1.0 cm2 interspersed with absorbers. Prototype modules, based on 6-inch hexagonal silicon pad sensors with 128 channels, have been constructed and include many of the features required for this challenging detector. In 2016, beam tests of sampling configurations made from these modules have been conducted both at FNAL and at CERN using the Skiroc2 front-end ASIC (designed by the CALICE collaboration for ILC). In 2017, the setup has been extended with CALICE's AHCAL prototype, a scinitillator based sampling calorimeter, and it was further tested in dedicated beam tests at CERN. There, the new Skiroc2-CMS front-end ASIC was used for the first time. We highlight final results from our studies in 2016, including position resolution as well as precision timing-measurements. Furthermore, the extended setup in 2017 is discussed and first results from beam tests with electrons and pions are shown.

  19. Charged particle detection performances of CMOS pixel sensors produced in a 0.18 μm process with a high resistivity epitaxial layer

    NASA Astrophysics Data System (ADS)

    Senyukov, S.; Baudot, J.; Besson, A.; Claus, G.; Cousin, L.; Dorokhov, A.; Dulinski, W.; Goffe, M.; Hu-Guo, C.; Winter, M.

    2013-12-01

    The apparatus of the ALICE experiment at CERN will be upgraded in 2017/18 during the second long shutdown of the LHC (LS2). A major motivation for this upgrade is to extend the physics reach for charmed and beauty particles down to low transverse momenta. This requires a substantial improvement of the spatial resolution and the data rate capability of the ALICE Inner Tracking System (ITS). To achieve this goal, the new ITS will be equipped with 50 μm thin CMOS Pixel Sensors (CPS) covering either the three innermost layers or all the 7 layers of the detector. The CPS being developed for the ITS upgrade at IPHC (Strasbourg) is derived from the MIMOSA 28 sensor realised for the STAR-PXL at RHIC in a 0.35 μm CMOS process. In order to satisfy the ITS upgrade requirements in terms of readout speed and radiation tolerance, a CMOS process with a reduced feature size and a high resistivity epitaxial layer should be exploited. In this respect, the charged particle detection performance and radiation hardness of the TowerJazz 0.18 μm CMOS process were studied with the help of the first prototype chip MIMOSA 32. The beam tests performed with negative pions of 120 GeV/c at the CERN-SPS allowed to measure a signal-to-noise ratio (SNR) for the non-irradiated chip in the range between 22 and 32 depending on the pixel design. The chip irradiated with the combined dose of 1 MRad and 1013neq /cm2 was observed to yield an SNR ranging between 11 and 23 for coolant temperatures varying from 15 °C to 30 °C. These SNR values were measured to result in particle detection efficiencies above 99.5% and 98% before and after irradiation, respectively. These satisfactory results allow to validate the TowerJazz 0.18 μm CMOS process for the ALICE ITS upgrade.

  20. Thermal management and prototype testing of Compton scattering X-ray beam position monitor for the Advanced Photon Source Upgrade

    DOE PAGES

    Lee, S. H.; Yang, B. X.; Collins, J. T.; ...

    2017-02-07

    Accurate and stable x-ray beam position monitors (XBPMs) are key elements in obtaining the desired user beam stability in the Advanced Photon Source Upgrade. In the next-generation XBPMs for the canted-undulator front ends, where two undulator beams are separated by 1.0 mrad, the lower beam power (<10 kW) per undulator allows us to explore lower-cost solutions based on Compton scattering from a diamond placed edge-on to the x-ray beam. Because of the high peak power density of the x-ray beams, this diamond experiences high temperatures and has to be clamped to a water-cooled heat spreader using thermal interface materials (TIMs),more » which play a key role in reducing the temperature of the diamond. To evaluate temperature changes through the interface via thermal simulations, the thermal contact resistance (TCR) of TIMs at an interface between two solid materials under even contact pressure must be known. This paper addresses the TCR measurements of several TIMs, including gold, silver, pyrolytic graphite sheet, and 3D graphene foam. In addition, a prototype of a Compton-scattering XBPM with diamond blades was installed at APS Beamline 24-ID-A in May 2015 and has been tested. This study presents the design of the Compton-scattering XBPM, and compares thermal simulation results obtained for the diamond blade of this XBPM by the finite element method with in situ empirical measurements obtained by using reliable infrared technology.« less

  1. First tests of a novel radiation hard CMOS sensor process for Depleted Monolithic Active Pixel Sensors

    NASA Astrophysics Data System (ADS)

    Pernegger, H.; Bates, R.; Buttar, C.; Dalla, M.; van Hoorne, J. W.; Kugathasan, T.; Maneuski, D.; Musa, L.; Riedler, P.; Riegel, C.; Sbarra, C.; Schaefer, D.; Schioppa, E. J.; Snoeys, W.

    2017-06-01

    The upgrade of the ATLAS [1] tracking detector for the High-Luminosity Large Hadron Collider (LHC) at CERN requires novel radiation hard silicon sensor technologies. Significant effort has been put into the development of monolithic CMOS sensors but it has been a challenge to combine a low capacitance of the sensing node with full depletion of the sensitive layer. Low capacitance brings low analog power. Depletion of the sensitive layer causes the signal charge to be collected by drift sufficiently fast to separate hits from consecutive bunch crossings (25 ns at the LHC) and to avoid losing the charge by trapping. This paper focuses on the characterization of charge collection properties and detection efficiency of prototype sensors originally designed in the framework of the ALICE Inner Tracking System (ITS) upgrade [2]. The prototypes are fabricated both in the standard TowerJazz 180nm CMOS imager process [3] and in an innovative modification of this process developed in collaboration with the foundry, aimed to fully deplete the sensitive epitaxial layer and enhance the tolerance to non-ionizing energy loss. Sensors fabricated in standard and modified process variants were characterized using radioactive sources, focused X-ray beam and test beams before and after irradiation. Contrary to sensors manufactured in the standard process, sensors from the modified process remain fully functional even after a dose of 1015neq/cm2, which is the the expected NIEL radiation fluence for the outer pixel layers in the future ATLAS Inner Tracker (ITk) [4].

  2. Assembly and analysis of a male sterile rubber tree mitochondrial genome reveals DNA rearrangement events and a novel transcript

    PubMed Central

    2014-01-01

    Background The rubber tree, Hevea brasiliensis, is an important plant species that is commercially grown to produce latex rubber in many countries. The rubber tree variety BPM 24 exhibits cytoplasmic male sterility, inherited from the variety GT 1. Results We constructed the rubber tree mitochondrial genome of a cytoplasmic male sterile variety, BPM 24, using 454 sequencing, including 8 kb paired-end libraries, plus Illumina paired-end sequencing. We annotated this mitochondrial genome with the aid of Illumina RNA-seq data and performed comparative analysis. We then compared the sequence of BPM 24 to the contigs of the published rubber tree, variety RRIM 600, and identified a rearrangement that is unique to BPM 24 resulting in a novel transcript containing a portion of atp9. Conclusions The novel transcript is consistent with changes that cause cytoplasmic male sterility through a slight reduction to ATP production efficiency. The exhaustive nature of the search rules out alternative causes and supports previous findings of novel transcripts causing cytoplasmic male sterility. PMID:24512148

  3. Submicron multi-bunch BPM for CLIC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmickler, H.; Soby, L.; /CERN

    2010-08-01

    A common-mode free cavity BPM is currently under development at Fermilab within the ILC-CLIC collaboration. This monitor will be operated in a CLIC Main Linac multi-bunch regime, and needs to provide both, high spatial and time resolution. We present the design concept, numerical analysis, investigation on tolerances and error effects, as well as simulations on the signal response applying a multi-bunch stimulus. The proposed CERN linear collider (CLIC) requires a very precise measurement of beam trajectory to preserve the low emittance when transporting the beam through the Main Linac. An energy chirp within the bunch train will be applied tomore » measure and minimize the dispersion effects, which require high resolution (in both, time and space) beam position monitors (BPM) along the beam-line. We propose a low-Q waveguide loaded TM{sub 110} dipole mode cavity as BPM, which is complemented by a TM{sub 010} monopole mode resonator of same resonant frequency for reference signal purposes. The design is based on a well known TM{sub 110} selective mode coupling idea.« less

  4. Growth performance and carcase quality in broiler chickens fed on bacterial protein grown on natural gas.

    PubMed

    Øverland, M; Schøyen, H F; Skrede, A

    2010-10-01

    1. The effects of increasing concentrations (0, 40, 80 or 120 g/kg) of bacterial protein meal (BPM) and bacterial protein autolysate (BPA) grown on natural gas on growth performance and carcase quality in broiler chickens were examined. 2. Adding BPM to diets reduced feed intake and improved gain: feed from 0 to 21 d and overall to 35 d, but did not significantly affect weight gain compared to the soybean meal based control diet. 3. Increasing concentrations of BPA significantly reduced growth rate, feed intake, gain: feed, carcase weight and dressing percentage, but significantly increased carcase dry matter, fat and energy content. 4. Adding BPM to diets had no effect on viscosity of diets and jejunal digesta, and minor effects on litter quality, whereas BPA increased the viscosity of diets and jejunal digesta, improved litter quality at 21 d, but decreased litter quality at 32 d. 5. To conclude, broiler chickens performed better on a BPM product with intact proteins than on an autolysate with ruptured cell walls and a high content of free amino acids and low molecular-weight peptides.

  5. Electromechanical Wave Imaging of biologically and electrically paced canine hearts in vivo

    PubMed Central

    Costet, Alexandre; Provost, Jean; Gambhir, Alok; Bobkov, Yevgeniy; Danilo, Peter; Boink, Gerard J.J.; Rosen, Michael R.; Konofagou, Elisa

    2014-01-01

    Ultrasound-based, Electromechanical Wave (EW) Imaging (EWI) can directly and entirely noninvasively map the transmural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability in localizing electronic and, for the first time, biological pacemakers in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR), and idioventricular rhythms occurring in dogs in heart block instrumented with electronic and biological pacemakers (EPM and BPM respectively). After AV node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n=4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n=2). EWI was performed transthoracically during NSR, BPM, and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/second. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison demonstrated that EWI was repeatable and reliable. These findings thus indicate the EWI potential to serve as a simple, noninvasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof. PMID:24239363

  6. Autonomic Dysfunction Precedes Development of Rheumatoid Arthritis: A Prospective Cohort Study

    PubMed Central

    Koopman, F.A.; Tang, M.W.; Vermeij, J.; de Hair, M.J.; Choi, I.Y.; Vervoordeldonk, M.J.; Gerlag, D.M.; Karemaker, J.M.; Tak, P.P.

    2016-01-01

    Background Heart rate variability (HRV) is a validated method to establish autonomic nervous system (ANS) activity. Rheumatoid arthritis (RA) is accompanied by ANS imbalance. We hypothesized that ANS dysfunction may precede the development of RA, which would suggest that it plays a role in its etiopathogenesis. Methods First, we assessed HRV parameters in supine (resting) and upright (active) position in healthy subjects (HS, n = 20), individuals at risk of developing arthritis (AR subjects, n = 50) and RA patients (RA, n = 20). Next, we measured resting heart rate (RHR), a parasympathetic HRV parameter, in an independent prospective cohort of AR subjects (n = 45). We also evaluated expression levels of the parasympathetic nicotinic acetylcholine receptor type 7 (α7nAChR) on circulating monocytes. Findings Both AR subjects (68 beats per minute (bpm), interquartile range (IQR) 68–73) and RA patients (68 bpm, IQR 62–76) had a significantly higher RHR compared to HS (60 bpm, IQR 56–63). RHR was significantly higher at baseline in individuals who subsequently developed arthritis. Expression levels of α7nAChR were lower in AR subjects with RHR ≥ 70 bpm compared to those with RHR < 70 bpm, consistent with reduced activity of the parasympathetic cholinergic anti-inflammatory pathway. Interpretation These data support the notion that autonomic dysfunction precedes the development of RA. PMID:27211565

  7. CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW)

    NASA Technical Reports Server (NTRS)

    Yamamoto, Clifford K.; Orozco, David S.; Byrne, D. J.; Allen, Steven J.; Sahasrabudhe, Adit; Lang, Minh

    2012-01-01

    This software provides essential startup and initialization routines for the CoNNeCT baseband processor module (BPM) hardware upon power-up. A command and data handling (C&DH) interface is provided via 1553 and diagnostic serial interfaces to invoke operational, reconfiguration, and test commands within the code. The BCSW has features unique to the hardware it is responsible for managing. In this case, the CoNNeCT BPM is configured with an updated CPU (Atmel AT697 SPARC processor) and a unique set of memory and I/O peripherals that require customized software to operate. These features include configuration of new AT697 registers, interfacing to a new HouseKeeper with a flash controller interface, a new dual Xilinx configuration/scrub interface, and an updated 1553 remote terminal (RT) core. The BCSW is intended to provide a "safe" mode for the BPM when initially powered on or when an unexpected trap occurs, causing the processor to reset. The BCSW allows the 1553 bus controller in the spacecraft or payload controller to operate the BPM over 1553 to upload code; upload Xilinx bit files; perform rudimentary tests; read, write, and copy the non-volatile flash memory; and configure the Xilinx interface. Commands also exist over 1553 to cause the CPU to jump or call a specified address to begin execution of user-supplied code. This may be in the form of a real-time operating system, test routine, or specific application code to run on the BPM.

  8. Hatching behavior of eastern long-necked turtles (Chelodina longicollis): The influence of asynchronous environments on embryonic heart rate and phenotype.

    PubMed

    McGlashan, Jessica K; Loudon, Fiona K; Thompson, Michael B; Spencer, Ricky-John

    2015-10-01

    Variable temperatures within a nest cause asynchronous development within clutches of freshwater turtle embryos, yet synchronous hatching occurs and is thought to be an important survival strategy for hatchlings. Metabolic compensation and circadian rhythms in heart rates of embryonic turtles indicate the potential of communication between embryos in a nest. Heart rates were used to identify metabolic circadian rhythms in clutches of an Australian freshwater turtle (Chelodina longicollis) and determine whether embryos metabolically compensate and hatch synchronously when incubated in asynchronous environments. The effects of a group environment during incubation on egg development and incubation period were also investigated during the final 3 weeks of development. Chelodina longicollis hatch synchronously and metabolically compensate so that less advanced embryos catch up to more advanced clutch-mates. Heart rates of embryos remained stable from week 4-7 in asynchronous (M=89 bpm) and synchronous (M=92 bpm) groups and declined in the final 2 weeks of incubation (M=72 and 77 bpm). Circadian rhythms were present throughout development and diel heart rates of embryos in asynchronous groups showed less deviation from the mean (M=-0.5 bpm) than synchronous groups (M=-4 bpm). Eggs incubated in groups had a significantly shorter incubation period than eggs incubated individually. Phenotypic traits including size, performance, and growth of all hatchlings were not affected. Egg position within a turtle nest is important for coordinating development throughout incubation and facilitating synchronous hatching. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Validation of the AVITA BPM64 upper-arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2018-02-01

    The aim of this study was to evaluate the accuracy of the automated oscillometric upper arm blood pressure (BP) monitor AVITA BPM64 for home BP monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic BPs were measured sequentially in 33 adult Chinese (14 women, mean age 47.0 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM64 device (one supervisor). A total of 99 pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM64 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 91/99, 98/99, and 98/99, respectively, for systolic BP and 92/99, 99/99, and 99/99, respectively, for diastolic BP. The device also fulfilled the criteria in part 2 of the validation study. Thirty-two participants for both systolic and diastolic BP had at least two of the three device-observer differences within 5 mmHg (required ≥24). Only one participant for systolic BP had all three device-observer comparisons greater than 5 mmHg. The AVITA upper arm BP monitor BPM64 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  10. BPM-CUL3 E3 ligase modulates thermotolerance by facilitating negative regulatory domain-mediated degradation of DREB2A in Arabidopsis

    PubMed Central

    Morimoto, Kyoko; Ohama, Naohiko; Kidokoro, Satoshi; Mizoi, Junya; Takahashi, Fuminori; Todaka, Daisuke; Mogami, Junro; Sato, Hikaru; Qin, Feng; Kim, June-Sik; Fukao, Yoichiro; Fujiwara, Masayuki; Shinozaki, Kazuo; Yamaguchi-Shinozaki, Kazuko

    2017-01-01

    DEHYDRATION-RESPONSIVE ELEMENT BINDING PROTEIN 2A (DREB2A) acts as a key transcription factor in both drought and heat stress tolerance in Arabidopsis and induces the expression of many drought- and heat stress-inducible genes. Although DREB2A expression itself is induced by stress, the posttranslational regulation of DREB2A, including protein stabilization, is required for its transcriptional activity. The deletion of a 30-aa central region of DREB2A known as the negative regulatory domain (NRD) transforms DREB2A into a stable and constitutively active form referred to as DREB2A CA. However, the molecular basis of this stabilization and activation has remained unknown for a decade. Here we identified BTB/POZ AND MATH DOMAIN proteins (BPMs), substrate adaptors of the Cullin3 (CUL3)-based E3 ligase, as DREB2A-interacting proteins. We observed that DREB2A and BPMs interact in the nuclei, and that the NRD of DREB2A is sufficient for its interaction with BPMs. BPM-knockdown plants exhibited increased DREB2A accumulation and induction of DREB2A target genes under heat and drought stress conditions. Genetic analysis indicated that the depletion of BPM expression conferred enhanced thermotolerance via DREB2A stabilization. Thus, the BPM-CUL3 E3 ligase is likely the long-sought factor responsible for NRD-dependent DREB2A degradation. Through the negative regulation of DREB2A stability, BPMs modulate the heat stress response and prevent an adverse effect of excess DREB2A on plant growth. Furthermore, we found the BPM recognition motif in various transcription factors, implying a general contribution of BPM-mediated proteolysis to divergent cellular responses via an accelerated turnover of transcription factors. PMID:28923951

  11. Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.

    PubMed

    Wiesel, Joseph; Arbesfeld, Benjamin; Schechter, David

    2014-10-01

    Screening for atrial fibrillation (AF) by assessing the pulse is recommended in high-risk patients. Some clinical trials demonstrated that the Microlife blood pressure monitor (BPM) with AF detection is more accurate than pulse palpation. This led to a change in practice guidelines in the United Kingdom where AF screening with the Microlife device is recommended instead of pulse palpation. Many BPMs have irregular heart beat detection, but they have not been shown to detect AF reliably. Recently, one study, in a highly select population, suggested that the Omron BPM with irregular heart beat detection has a higher sensitivity for AF than the Microlife BPM. We compared the Microlife and Omron BPMs to electrocardiographic readings for AF detection in general cardiology patients. Inclusion criteria were age≥50 years without a pacemaker or defibrillator. A total of 199 subjects were enrolled, 30 with AF. Each subject had a 12-lead electrocardiography, 1 Omron BPM reading, and 3 Microlife BPM readings as per device instructions. The Omron device had a sensitivity of 30% (95% confidence interval [CI] 15.4% to 49.1%) with the sensitivity for the first Microlife reading of 97% (95% CI 81.4% to 100%) and the Microlife readings using the majority rule (AF positive if at least 2 of 3 individual readings were positive for AF) of 100% (95% CI 85.9% to 100%). Specificity for the Omron device was 97% (95% CI 92.5% to 99.2%) and for the first Microlife reading of 90% (95% CI 83.8% to 94.2%) and for the majority rule Microlife device of 92% (95% CI 86.2% to 95.7%; p<0.0001). The specificity of both devices is acceptable, but only the Microlife BPM has a sensitivity value that is high enough to be used for AF screening in clinical practice. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram.

    PubMed

    Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J

    2016-04-01

    Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of  -4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and  -5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of  -5.6 to 5.2 bpm and a bias of  -0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available.

  13. Accuracy of a Wrist-Worn Wearable Device for Monitoring Heart Rates in Hospital Inpatients: A Prospective Observational Study.

    PubMed

    Kroll, Ryan R; Boyd, J Gordon; Maslove, David M

    2016-09-20

    As the sensing capabilities of wearable devices improve, there is increasing interest in their application in medical settings. Capabilities such as heart rate monitoring may be useful in hospitalized patients as a means of enhancing routine monitoring or as part of an early warning system to detect clinical deterioration. To evaluate the accuracy of heart rate monitoring by a personal fitness tracker (PFT) among hospital inpatients. We conducted a prospective observational study of 50 stable patients in the intensive care unit who each completed 24 hours of heart rate monitoring using a wrist-worn PFT. Accuracy of heart rate recordings was compared with gold standard measurements derived from continuous electrocardiographic (cECG) monitoring. The accuracy of heart rates measured by pulse oximetry (Spo2.R) was also measured as a positive control. On a per-patient basis, PFT-derived heart rate values were slightly lower than those derived from cECG monitoring (average bias of -1.14 beats per minute [bpm], with limits of agreement of 24 bpm). By comparison, Spo2.R recordings produced more accurate values (average bias of +0.15 bpm, limits of agreement of 13 bpm, P<.001 as compared with PFT). Personal fitness tracker device performance was significantly better in patients in sinus rhythm than in those who were not (average bias -0.99 bpm vs -5.02 bpm, P=.02). Personal fitness tracker-derived heart rates were slightly lower than those derived from cECG monitoring in real-world testing and not as accurate as Spo2.R-derived heart rates. Performance was worse among patients who were not in sinus rhythm. Further clinical evaluation is indicated to see if PFTs can augment early warning systems in hospitals. ClinicalTrials.gov NCT02527408; https://clinicaltrials.gov/ct2/show/NCT02527408 (Archived by WebCite at  http://www.webcitation.org/6kOFez3on).

  14. Diurnal, seasonal, and sex patterns of heart rate in grip-restrained African giant rats (Cricetomys gambianus, Waterhouse).

    PubMed

    Dzenda, Tavershima; Ayo, Joseph O; Sinkalu, Victor O; Yaqub, Lukuman S

    2015-10-01

    This study was carried out to determine heart rate (HR) values, including diurnal, seasonal, and sex patterns, in the African giant rat (Cricetomys gambianus, Waterhouse). HR was measured using stethoscope in grip-restrained African giant rats of either sex (103 bucks and 98 does), live-trapped from a tropical Savannah, and caged individually in the laboratory during the harmattan (cold-dry), hot-dry, and rainy seasons over a 3-year period. The HR fluctuated between 90 and 210 beats per minute (bpm) throughout the study period. Diurnal changes in HR (mean ± SEM) during the hot-dry and rainy seasons were nonsignificant (P > 0.05), but the morning and afternoon values differed (P < 0.01) during the cold-dry season. The HR varied (P < 0.05) among seasons, with peak, nadir, and moderate values recorded during the cold-dry (165.8 ± 0.51 bpm), hot-dry (153.1 ± 0.74 bpm), and rainy (163.4 ± 0.70 bpm) seasons, respectively. Mean HR of bucks was lower than that of does during the cold-dry (P < 0.0001) and hot-dry (P < 0.01) seasons, but sex difference during the rainy season was insignificant (P > 0.05). Overall, mean HR was lower (P < 0.0001) in bucks (158.8 ± 0.53 bpm) than in does (164.8 ± 0.53 bpm). In conclusion, values of HR in African giant rats are shown for the first time. Season, sex, and daytime influenced the HR, and should be considered during clinical evaluations of the rats. © 2015 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of the American Physiological Society and The Physiological Society.

  15. An assessment of algorithms to estimate respiratory rate from the electrocardiogram and photoplethysmogram

    PubMed Central

    Charlton, Peter H; Bonnici, Timothy; Tarassenko, Lionel; Clifton, David A; Beale, Richard; Watkinson, Peter J

    2016-01-01

    Abstract Over 100 algorithms have been proposed to estimate respiratory rate (RR) from the electrocardiogram (ECG) and photoplethysmogram (PPG). As they have never been compared systematically it is unclear which algorithm performs the best. Our primary aim was to determine how closely algorithms agreed with a gold standard RR measure when operating under ideal conditions. Secondary aims were: (i) to compare algorithm performance with IP, the clinical standard for continuous respiratory rate measurement in spontaneously breathing patients; (ii) to compare algorithm performance when using ECG and PPG; and (iii) to provide a toolbox of algorithms and data to allow future researchers to conduct reproducible comparisons of algorithms. Algorithms were divided into three stages: extraction of respiratory signals, estimation of RR, and fusion of estimates. Several interchangeable techniques were implemented for each stage. Algorithms were assembled using all possible combinations of techniques, many of which were novel. After verification on simulated data, algorithms were tested on data from healthy participants. RRs derived from ECG, PPG and IP were compared to reference RRs obtained using a nasal-oral pressure sensor using the limits of agreement (LOA) technique. 314 algorithms were assessed. Of these, 270 could operate on either ECG or PPG, and 44 on only ECG. The best algorithm had 95% LOAs of  −4.7 to 4.7 bpm and a bias of 0.0 bpm when using the ECG, and  −5.1 to 7.2 bpm and 1.0 bpm when using PPG. IP had 95% LOAs of  −5.6 to 5.2 bpm and a bias of  −0.2 bpm. Four algorithms operating on ECG performed better than IP. All high-performing algorithms consisted of novel combinations of time domain RR estimation and modulation fusion techniques. Algorithms performed better when using ECG than PPG. The toolbox of algorithms and data used in this study are publicly available. PMID:27027672

  16. Is 10-second electrocardiogram recording enough for accurately estimating heart rate in atrial fibrillation.

    PubMed

    Shuai, Wei; Wang, Xi-Xing; Hong, Kui; Peng, Qiang; Li, Ju-Xiang; Li, Ping; Chen, Jing; Cheng, Xiao-Shu; Su, Hai

    2016-07-15

    At present, the estimation of rest heart rate (HR) in atrial fibrillation (AF) is obtained by apical auscultation for 1min or on the surface electrocardiogram (ECG) by multiplying the number of RR intervals on the 10second recording by six. But the reasonability of 10second ECG recording is controversial. ECG was continuously recorded at rest for 60s to calculate the real rest HR (HR60s). Meanwhile, the first 10s and 30s ECG recordings were used for calculating HR10s (sixfold) and HR30s (twofold). The differences of HR10s or HR30s with the HR60s were compared. The patients were divided into three sub-groups on the HR60s <80, 80-100 and >100bpm. No significant difference among the mean HR10s, HR30s and HR60s was found. A positive correlation existed between HR10s and HR60s or HR30s and HR60s. Bland-Altman plot showed that the 95% reference limits were high as -11.0 to 16.0bpm for HR10s, but for HR30s these values were only -4.5 to 5.2bpm. Among the three subgroups with HR60s <80, 80-100 and >100bpm, the 95% reference limits with HR60s were -8.9 to 10.6, -10.5 to 14.0 and -11.3 to 21.7bpm for HR10s, but these values were -3.9 to 4.3, -4.1 to 4.6 and -5.3 to 6.7bpm for HR30s. As 10s ECG recording could not provide clinically accepted estimation HR, ECG should be recorded at least for 30s in the patients with AF. It is better to record ECG for 60s when the HR is rapid. Copyright © 2016. Published by Elsevier Ireland Ltd.

  17. Impact of heart rate in atrial fibrillation versus sinus rhythm on mortality in octogenarian patients with acute coronary syndrome.

    PubMed

    Li, Shijun; Barywani, Salim; Fu, Michael

    2017-01-01

    Association of heart rate (HR) with mortality in patients with acute coronary syndrome (ACS) and aged ≥ 80 years are underrepresented in clinical trials. We therefore aimed to investigate the association of HR in atrial fibrillation (AF) versus sinus rhythm (SR) with all-cause mortality in octogenarian patients with ACS. A total of 336 patients with ACS patients and aged ≥ 80 years were enrolled into the current study. The end point of interest was death from any cause. Association of HR in AF versus SR with mortality was analyzed by Kaplan-Meier curve following log-rank test and multivariable Cox regression analysis. In total, 63 (87.5%) of patients with AF were dead and 147 (59.8%) of patients with SR were dead during the follow-up period. The best cut-off was 80 bpm, with a sensitivity of 62% and specificity of 66%. HR ≤ 80 bpm in SR but not in AF was associated with better outcome as compared with HR > 80 bpm (Chi-Square = 26.55, Log rank P < 0.001). In SR subgroup, the hazard ratios of HR ≤ 80 bpm were 0.51(95% CI 0.37-0.70, P < 0.001) adjusted for age, 0.46 (95%CI 0.33-0.63, P < 0.001) adjusted for gender, 0.62 (95%CI 0.42- 0.93, P = 0.020) adjusted for multivariables respectively. In AF subgroup, the hazard ratios of HR ≤ 80 bpm were 0.83(95% CI 0.49-1.38, P = 0.464) adjusted for age, 0.96 (95%CI 0.59-1.58, P = 0.882) adjusted for gender, 0.72(95% CI 0.41-1.26, P = 0.249) adjusted for multivariables respectively. The current study demonstrates that heart rate is an independent prognostic predictor for all-cause mortality, and HR ≤ 80 bpm is associated with improved outcome in SR but not in AF in octogenarian patients with ACS.

  18. Testbeam results of irradiated ams H18 HV-CMOS pixel sensor prototypes

    DOE PAGES

    Benoit, M.; Braccini, S.; Casse, G.; ...

    2018-02-08

    HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the 4 th generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between 1×10 14 and 5×10 15 1–MeV– n eq. The sensors were glued to ATLAS FE-I4 pixel readout chips and measured atmore » the CERN SPS H8 beamline using the FE-I4 beam telescope. Results for all fluences are very encouraging with all hit efficiencies being better than 97% for bias voltages of 85 V. The sample irradiated to a fluence of 1×10 15 neq—a relevant value for a large volume of the upgraded tracker—exhibited 99.7% average hit efficiency. Furthermore, the results give strong evidence for the radiation tolerance of HV-CMOS sensors and their suitability as sensors for the experimental HL-LHC upgrades and future large-area silicon-based tracking detectors in high-radiation environments.« less

  19. High-voltage pixel sensors for ATLAS upgrade

    NASA Astrophysics Data System (ADS)

    Perić, I.; Kreidl, C.; Fischer, P.; Bompard, F.; Breugnon, P.; Clemens, J.-C.; Fougeron, D.; Liu, J.; Pangaud, P.; Rozanov, A.; Barbero, M.; Feigl, S.; Capeans, M.; Ferrere, D.; Pernegger, H.; Ristic, B.; Muenstermann, D.; Gonzalez Sevilla, S.; La Rosa, A.; Miucci, A.; Nessi, M.; Iacobucci, G.; Backhaus, M.; Hügging, Fabian; Krüger, H.; Hemperek, T.; Obermann, T.; Wermes, N.; Garcia-Sciveres, M.; Quadt, A.; Weingarten, J.; George, M.; Grosse-Knetter, J.; Rieger, J.; Bates, R.; Blue, A.; Buttar, C.; Hynds, D.

    2014-11-01

    The high-voltage (HV-) CMOS pixel sensors offer several good properties: a fast charge collection by drift, the possibility to implement relatively complex CMOS in-pixel electronics and the compatibility with commercial processes. The sensor element is a deep n-well diode in a p-type substrate. The n-well contains CMOS pixel electronics. The main charge collection mechanism is drift in a shallow, high field region, which leads to a fast charge collection and a high radiation tolerance. We are currently evaluating the use of the high-voltage detectors implemented in 180 nm HV-CMOS technology for the high-luminosity ATLAS upgrade. Our approach is replacing the existing pixel and strip sensors with the CMOS sensors while keeping the presently used readout ASICs. By intelligence we mean the ability of the sensor to recognize a particle hit and generate the address information. In this way we could benefit from the advantages of the HV sensor technology such as lower cost, lower mass, lower operating voltage, smaller pitch, smaller clusters at high incidence angles. Additionally we expect to achieve a radiation hardness necessary for ATLAS upgrade. In order to test the concept, we have designed two HV-CMOS prototypes that can be readout in two ways: using pixel and strip readout chips. In the case of the pixel readout, the connection between HV-CMOS sensor and the readout ASIC can be established capacitively.

  20. Testbeam results of irradiated ams H18 HV-CMOS pixel sensor prototypes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benoit, M.; Braccini, S.; Casse, G.

    HV-CMOS pixel sensors are a promising option for the tracker upgrade of the ATLAS experiment at the LHC, as well as for other future tracking applications in which large areas are to be instrumented with radiation-tolerant silicon pixel sensors. We present results of testbeam characterisations of the 4 th generation of Capacitively Coupled Pixel Detectors (CCPDv4) produced with the ams H18 HV-CMOS process that have been irradiated with different particles (reactor neutrons and 18 MeV protons) to fluences between 1×10 14 and 5×10 15 1–MeV– n eq. The sensors were glued to ATLAS FE-I4 pixel readout chips and measured atmore » the CERN SPS H8 beamline using the FE-I4 beam telescope. Results for all fluences are very encouraging with all hit efficiencies being better than 97% for bias voltages of 85 V. The sample irradiated to a fluence of 1×10 15 neq—a relevant value for a large volume of the upgraded tracker—exhibited 99.7% average hit efficiency. Furthermore, the results give strong evidence for the radiation tolerance of HV-CMOS sensors and their suitability as sensors for the experimental HL-LHC upgrades and future large-area silicon-based tracking detectors in high-radiation environments.« less

  1. Energy Efficiency Potential in the U.S. Single-Family Housing Stock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, Eric J.; Christensen, Craig B.; Horowitz, Scott G.

    Typical approaches for assessing energy efficiency potential in buildings use a limited number of prototypes, and therefore suffer from inadequate resolution when pass-fail cost-effectiveness tests are applied, which can significantly underestimate or overestimate the economic potential of energy efficiency technologies. This analysis applies a new approach to large-scale residential energy analysis, combining the use of large public and private data sources, statistical sampling, detailed building simulations, and high-performance computing to achieve unprecedented granularity - and therefore accuracy - in modeling the diversity of the single-family housing stock. The result is a comprehensive set of maps, tables, and figures showing themore » technical and economic potential of 50 plus residential energy efficiency upgrades and packages for each state. Policymakers, program designers, and manufacturers can use these results to identify upgrades with the highest potential for cost-effective savings in a particular state or region, as well as help identify customer segments for targeted marketing and deployment. The primary finding of this analysis is that there is significant technical and economic potential to save electricity and on-site fuel use in the single-family housing stock. However, the economic potential is very sensitive to the cost-effectiveness criteria used for analysis. Additionally, the savings of particular energy efficiency upgrades is situation-specific within the housing stock (depending on climate, building vintage, heating fuel type, building physical characteristics, etc.).« less

  2. The new front-end electronics for the ATLAS Tile Calorimeter Phase 2 Upgrade

    NASA Astrophysics Data System (ADS)

    Gomes, A.

    2016-02-01

    We present the plans, design, and performance results to date for the new front-end electronics being developed for the Phase 2 Upgrade of the ATLAS Tile Calorimeter. The front-end electronics will be replaced to address the increased luminosity at the HL-LHC around 2025, as well as to upgrade to faster, more modern components with higher radiation tolerance. The new electronics will operate dead-timelessly, pushing full data sets from each beam crossing to the data acquisition system that resides off-detector. The new on-detector electronics contains five main parts: the front-end boards that connect directly to the photomultiplier tubes; the Main Boards that digitize the data; the Daughter Boards that collect the data streams and contain the high speed optical communication links for writing data to the data acquisition system; a programmable high voltage control system; and a new low voltage power supply. There are different options for implementing these subcomponents, which will be described. The new system contains new features that in the current version include power system redundancy, data collection redundancy, data transmission redundancy with 2 QSFP optical transceivers and Kintex-7 FPGAs with firmware enhanced scheme for single event upset mitigation. To date, we have built a Demonstrator—a fully functional prototype of the new system. Performance results and plans are presented.

  3. Changes in Functional Mobility and Musculoskeletal Pain After Bariatric Surgery in Teens With Severe Obesity: Teen-Longitudinal Assessment of Bariatric Surgery (LABS) Study.

    PubMed

    Ryder, Justin R; Edwards, Nicholas M; Gupta, Resmi; Khoury, Jane; Jenkins, Todd M; Bout-Tabaku, Sharon; Michalsky, Marc P; Harmon, Carroll M; Inge, Thomas H; Kelly, Aaron S

    2016-09-01

    Severe obesity is associated with mobility limitations and higher incidence of multijoint musculoskeletal pain. It is unknown whether substantial weight loss improves these important outcomes in adolescents with severe obesity. To examine the association of bariatric surgery with functional mobility and musculoskeletal pain in adolescents with severe obesity up to 2 years after surgery. The Teen-Longitudinal Assessment of Bariatric Surgery Study is a prospective, multicenter, observational study, which enrolled 242 adolescents (≤19 years of age) who were undergoing bariatric surgery from March 2007 through February 2012 at 5 US adolescent bariatric surgery centers. This analysis was conducted in November 2015. Roux-en-Y gastric bypass (n = 161), sleeve gastrectomy (n = 67), or laparoscopic adjustable gastric band (n = 14). Participants completed a 400-m walk test prior to bariatric surgery (n = 206) and at 6 months (n = 195), 12 months (n = 176), and 24 months (n = 149) after surgery. Time to completion, resting heart rate (HR), immediate posttest HR, and HR difference (resting HR minus posttest HR) were measured and musculoskeletal pain concerns, during and after the test, were documented. Data were adjusted for age, sex, race/ethnicity, baseline body mass index (calculated as weight in kilograms divided by height in meters squared), and surgical center (posttest HR and HR difference were further adjusted for changes in time to completion). Of the 206 adolescents with severe obesity included in the study, 156 were female (75.7%), the mean (SD) age was 17.1 (1.6) years, and the mean (SD) body mass index was 51.7 (8.5). Compared with baseline, significant improvements were observed at 6 months for the walk test time to completion (mean, 376 seconds; 95% CI, 365-388 to 347 seconds; 95% CI, 340-358; P < .01), resting HR (mean, 84 beats per minute [bpm]; 95% CI, 82-86 to 74 bpm; 95% CI, 72-76), posttest HR (mean, 128 bpm; 95% CI, 125-131 to 113 bpm; 95% CI, 110-116), and HR difference (mean, 40 bpm; 95% CI, 36-42 to 34 bpm; 95% CI, 31-37). These changes in time to completion, resting HR, and HR difference persisted at 12 months and 24 months. Posttest HR further improved from 6 months to 12 months (mean, 113 bpm; 95% CI, 110-116 to 108 bpm; 95% CI, 105-111). There were statistically significant reductions in musculoskeletal pain concerns at all points. These data provide evidence that bariatric surgery in adolescents with severe obesity is associated with significant improvement in functional mobility and in the reduction of walking-related musculoskeletal pain up to 2 years after surgery.

  4. Optimization of Gas Metal Arc Welding (GMAW) Process for Maximum Ballistic Limit in MIL A46100 Steel Welded All-Metal Armor

    NASA Astrophysics Data System (ADS)

    Grujicic, M.; Ramaswami, S.; Snipes, J. S.; Yavari, R.; Yen, C.-F.; Cheeseman, B. A.

    2015-01-01

    Our recently developed multi-physics computational model for the conventional gas metal arc welding (GMAW) joining process has been upgraded with respect to its predictive capabilities regarding the process optimization for the attainment of maximum ballistic limit within the weld. The original model consists of six modules, each dedicated to handling a specific aspect of the GMAW process, i.e., (a) electro-dynamics of the welding gun; (b) radiation-/convection-controlled heat transfer from the electric arc to the workpiece and mass transfer from the filler metal consumable electrode to the weld; (c) prediction of the temporal evolution and the spatial distribution of thermal and mechanical fields within the weld region during the GMAW joining process; (d) the resulting temporal evolution and spatial distribution of the material microstructure throughout the weld region; (e) spatial distribution of the as-welded material mechanical properties; and (f) spatial distribution of the material ballistic limit. In the present work, the model is upgraded through the introduction of the seventh module in recognition of the fact that identification of the optimum GMAW process parameters relative to the attainment of the maximum ballistic limit within the weld region entails the use of advanced optimization and statistical sensitivity analysis methods and tools. The upgraded GMAW process model is next applied to the case of butt welding of MIL A46100 (a prototypical high-hardness armor-grade martensitic steel) workpieces using filler metal electrodes made of the same material. The predictions of the upgraded GMAW process model pertaining to the spatial distribution of the material microstructure and ballistic limit-controlling mechanical properties within the MIL A46100 butt weld are found to be consistent with general expectations and prior observations.

  5. An Econometric Examination of the Behavioral Perspective Model in the Context of Norwegian Retailing

    ERIC Educational Resources Information Center

    Sigurdsson, Valdimar; Kahamseh, Saeed; Gunnarsson, Didrik; Larsen, Nils Magne; Foxall, Gordon R.

    2013-01-01

    The behavioral perspective model's (BPM; Foxall, 1990) retailing literature is built on extensive empirical research and techniques that were originally refined in choice experiments in behavioral economics and behavior analysis, and then tested mostly on British consumer panel data. We test the BPM in the context of Norwegian retailing. This…

  6. Towards an Understanding of the Business Process Analyst: An Analysis of Competencies

    ERIC Educational Resources Information Center

    Sonteya, Thembela; Seymour, Lisa

    2012-01-01

    The increase in adoption of business process management (BPM) and service oriented architecture (SOA) has created a high demand for qualified professionals with a plethora of skills. However, despite the growing amount of literature available on the topics of BPM and SOA, little research has been conducted around developing a detailed list of…

  7. A neutral-beam profile monitor with a phosphor screen and a high-sensitivity camera for the J-PARC KOTO experiment

    NASA Astrophysics Data System (ADS)

    Matsumura, T.; Kamiji, I.; Nakagiri, K.; Nanjo, H.; Nomura, T.; Sasao, N.; Shinkawa, T.; Shiomi, K.

    2018-03-01

    We have developed a beam-profile monitor (BPM) system to align the collimators for the neutral beam-line at the Hadron Experimental Facility of J-PARC. The system is composed of a phosphor screen and a CCD camera coupled to an image intensifier mounted on a remote control X- Y stage. The design and detailed performance studies of the BPM are presented. The monitor has a spatial resolution of better than 0.6 mm and a deviation from linearity of less than 1%. These results indicate that the BPM system meets the requirements to define collimator-edge positions for the beam-line tuning. Confirmation using the neutral beam for the KOTO experiment is also presented.

  8. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    NASA Astrophysics Data System (ADS)

    Thieberger, P.; Gassner, D.; Hulsart, R.; Michnoff, R.; Miller, T.; Minty, M.; Sorrell, Z.; Bartnik, A.

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  9. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE PAGES

    Thieberger, Peter; Gassner, D.; Hulsart, R.; ...

    2018-04-25

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  10. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thieberger, Peter; Gassner, D.; Hulsart, R.

    Here, a simple, analytically correct algorithm is developed for calculating “pencil” relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a FPGA-based BPM readout implementation of the new algorithm has been developed and characterized. Lastly, the algorithm ismore » tested with BPM data from the Cornell Preinjector.« less

  11. Fast readout algorithm for cylindrical beam position monitors providing good accuracy for particle bunches with large offsets.

    PubMed

    Thieberger, P; Gassner, D; Hulsart, R; Michnoff, R; Miller, T; Minty, M; Sorrell, Z; Bartnik, A

    2018-04-01

    A simple, analytically correct algorithm is developed for calculating "pencil" relativistic beam coordinates using the signals from an ideal cylindrical particle beam position monitor (BPM) with four pickup electrodes (PUEs) of infinitesimal widths. The algorithm is then applied to simulations of realistic BPMs with finite width PUEs. Surprisingly small deviations are found. Simple empirically determined correction terms reduce the deviations even further. The algorithm is then tested with simulations for non-relativistic beams. As an example of the data acquisition speed advantage, a Field Programmable Gate Array-based BPM readout implementation of the new algorithm has been developed and characterized. Finally, the algorithm is tested with BPM data from the Cornell Preinjector.

  12. MIA analysis of FPGA BPMs and beam optics at APS

    NASA Astrophysics Data System (ADS)

    Ji, Da-Heng; Wang, Chun-Xi; Qin, Qing

    2012-11-01

    Model independent analysis, which was developed for high precision and fast beam dynamics analysis, is a promising diagnostic tool for modern accelerators. We implemented a series of methods to analyze the turn-by-turn BPM data. Green's functions corresponding to the local transfer matrix elements R12 or R34 are extracted from BPM data and fitted with the model lattice using least-square fitting. Here, we report experimental results obtained from analyzing the transverse motion of a beam in the storage ring at the Advanced Photon Source. BPM gains and uncoupled optics parameters are successfully determined. Quadrupole strengths are adjusted for fitting but can not be uniquely determined in general due to an insufficient number of BPMs.

  13. SiFAP: a Simple Sub-Millisecond Astronomical Photometer

    NASA Astrophysics Data System (ADS)

    Ambrosino, F.; Meddi, F.; Nesci, R.; Rossi, C.; Sclavi, S.; Bruni, I.

    2013-09-01

    A new fast photometer based on SiPM technology was developed at the University of Rome "La Sapienza" starting from 2009. A first prototype was successfully tested observing the Crab pulsar at the Loiano telescope of the Bologna Observatory. In this paper we illustrate the improvements we applied to our instrument, concerning new cooled commercial sensors, a new version of our custom dedicated electronics and an upgraded control timing software. Finally we report the results obtained with this instrument on December 2012 on the Crab pulsar at the Loiano telescope to show its goodness and capabilities.

  14. Management and development of local area network upgrade prototype

    NASA Technical Reports Server (NTRS)

    Fouser, T. J.

    1981-01-01

    Given the situation of having management and development users accessing a central computing facility and given the fact that these same users have the need for local computation and storage, the utilization of a commercially available networking system such as CP/NET from Digital Research provides the building blocks for communicating intelligent microsystems to file and print services. The major problems to be overcome in the implementation of such a network are the dearth of intelligent communication front-ends for the microcomputers and the lack of a rich set of management and software development tools.

  15. A TTC upgrade proposal using bidirectional 10G-PON FTTH technology

    NASA Astrophysics Data System (ADS)

    Kolotouros, D. M.; Baron, S.; Soos, C.; Vasey, F.

    2015-04-01

    A new generation FPGA-based Timing-Trigger and Control (TTC) system based on emerging Passive Optical Network (PON) technology is being proposed to replace the existing off-detector TTC system used by the LHC experiments. High split ratio, dynamic software partitioning, low and deterministic latency, as well as low jitter are required. Exploiting the latest available technologies allows delivering higher capacity together with bidirectionality, a feature absent from the legacy TTC system. This article focuses on the features and capabilities of the latest TTC-PON prototype based on 10G-PON FTTH components along with some metrics characterizing its performance.

  16. Relation between detection rate and inappropriate shocks in single versus dual chamber cardioverter-defibrillator – an analysis from the OPTION trial

    PubMed Central

    Kolb, Christof; Sturmer, Marcio; Babuty, Dominique; Sick, Peter; Davy, Jean Marc; Molon, Giulio; Schwab, Jörg Otto; Mantovani, Giuseppe; Wickliffe, Andrew; Lennerz, Carsten; Semmler, Verena; Siot, Pierre-Henri; Reif , Sebastian

    2016-01-01

    The programming of implantable cardioverter-defibrillators (ICDs) influences inappropriate shock rates. The aim of the study is to analyse rates of patients with appropriate and inappropriate shocks according to detection zones in the OPTION trial. All patients received dual chamber (DC) ICDs randomly assigned to be programmed either to single chamber (SC) or to DC settings including PARAD+ algorithm. In a post-hoc analysis, rates of patients with inappropriate and appropriate shocks were calculated for shocks triggered at heart rates ≥170 bpm (ventricular tachycardia zone) and at rates ≥200 bpm (ventricular fibrillation zone). In the SC group, higher rates of patients with total and inappropriate shocks were delivered at heart rates ≥170 bpm than at rates ≥200 bpm (total shocks: 21.1% vs. 16.6%; p = 0.002; inappropriate shocks: 7.6% vs. 4.5%, p = 0.016; appropriate shocks: 15.2% vs. 13.5%; p = n.s.). No such differences were observed in the DC group (total shocks: 14.3% vs. 12.6%; p = n.s.; inappropriate shocks: 3.9% vs. 3.6%; p = n.s.; appropriate shocks: 12.2% vs. 10.4%; p = n.s.). The higher frequency of patients with total shocks with SC settings than with DC settings that benefit from PARAD+ was driven by a higher percentage of patients with inappropriate shocks in the VT zone (170–200 bpm) in the SC population. PMID:26892534

  17. The Brief Problem Monitor-Parent form (BPM-P), a short version of the Child Behavior Checklist: Psychometric properties in Spanish 6- to 8-year-old children.

    PubMed

    Penelo, Eva; de la Osa, Núria; Navarro, José Blas; Domènech, Josep Maria; Ezpeleta, Lourdes

    2017-11-01

    We provide the first validation data on the Spanish version of the Brief Problem Monitor-Parent form (BPM-P), a recently developed abbreviated version of the 120-item Child Behavior Checklist for Ages 6 to 18 (CBCL/6-18) in young schoolchildren. Parents of a community sample of 521 children aged 6-8 answered the CBCL/6-18 yearly, and the 19 BPM-P items were examined; parents also provided different measures of psychopathology. Confirmatory factor analysis of the expected 3-factor model (attention, externalizing, and internalizing) showed adequate fit (root mean square error of approximation, RMSEA ≤ .057), and measurement invariance across sex and age was observed. Internal consistency for the derived scores was satisfactory (ω ≥ .83). Concurrent validity with the equivalent scale scores of the original full CBCL/6-18 (r ≥ .84) and convergent validity with parents' ratings of the Strengths and Difficulties Questionnaire scores (r ≥ .52) were good. BPM-P scores at age 7 showed good predictive accuracy for discriminating the use of mental health services (OR ≥ 1.12), functional impairment (B ≤ -1.25), and the presence of the corresponding disorders diagnosed with an independent clinical interview, both cross-sectionally at age 7 and longitudinally at age 8 (OR ≥ 1.24). The BPM-P provides reliable and valid scores as a very brief follow-up and screening tool for assessing behavioral and emotional problems in young schoolchildren. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  18. Validation of the AVITA BPM15S wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Zhang, Lu; Li, Yan; Wang, Ji-Guang

    2014-06-01

    The present study aimed to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM15S for home blood pressure monitoring according to the International Protocol revision 2010 of the European Society of Hypertension. Systolic and diastolic blood pressures were sequentially measured in 33 Chinese adults (15 women, mean age 51 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM15S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM15S device achieved the targets in part 1 of the validation study. The number of absolute differences between the device and observers within 5, 10, and 15 mmHg were 85/99, 94/99, and 98/99, respectively, for systolic blood pressure, and 82/99, 96/99, and 98/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Thirty-two and 28 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observer differences within 5 mmHg (required ≥ 24). No participant had all of the three device-observer comparisons greater than 5 mmHg for systolic or diastolic blood pressure. The AVITA wrist blood pressure monitor BPM15S fulfilled the requirements of the International Protocol revision 2010 and hence can be recommended for home use in an adult population.

  19. Validation of the AVITA BPM17 wrist blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Chen, Qi; Liu, Chang-Yuan; Li, Yan; Wang, Ji-Guang

    2017-08-01

    The aim of the present study was to evaluate the accuracy of the automated oscillometric wrist blood pressure monitor AVITA BPM17 for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (19 men, 45.7 years of mean age) using a mercury sphygmomanometer (two observers) and the AVITA BPM17 device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. The AVITA BPM17 device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 94/99, 98/99, and 98/99, respectively, for systolic blood pressure and 92/99, 99/99, and 99/99, respectively, for diastolic blood pressure. The device also fulfilled the criteria in part 2 of the validation study. Overall, 32 participants for both systolic and diastolic blood pressure, respectively, had at least two of the three device-observerss differences within 5 mmHg (required ≥24). None had all the three device-observers comparisons greater than 5 mmHg for systolic and diastolic blood pressure. The AVITA wrist blood pressure monitor BPM17 has passed the requirements of the International Protocol revision 2010, and hence can be recommended for home use in adults.

  20. Test of the CLAS12 RICH large-scale prototype in the direct proximity focusing configuration

    DOE PAGES

    Anefalos Pereira, S.; Baltzell, N.; Barion, L.; ...

    2016-02-11

    A large area ring-imaging Cherenkov detector has been designed to provide clean hadron identification capability in the momentum range from 3 GeV/c up to 8 GeV/c for the CLAS12 experiments at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Laboratory. The adopted solution foresees a novel hybrid optics design based on aerogel radiator, composite mirrors and high-packed and high-segmented photon detectors. Cherenkov light will either be imaged directly (forward tracks) or after two mirror reflections (large angle tracks). We report here the results of the tests of a large scale prototype of the RICH detector performed withmore » the hadron beam of the CERN T9 experimental hall for the direct detection configuration. As a result, the tests demonstrated that the proposed design provides the required pion-to-kaon rejection factor of 1:500 in the whole momentum range.« less

  1. Flight Test Results for the F-16XL With a Digital Flight Control System

    NASA Technical Reports Server (NTRS)

    Stachowiak, Susan J.; Bosworth, John T.

    2004-01-01

    In the early 1980s, two F-16 airplanes were modified to extend the fuselage length and incorporate a large area delta wing planform. These two airplanes, designated the F-16XL, were designed by the General Dynamics Corporation (now Lockheed Martin Tactical Aircraft Systems) (Fort Worth, Texas) and were prototypes for a derivative fighter evaluation program conducted by the United States Air Force. Although the concept was never put into production, the F-16XL prototypes provided a unique planform for testing concepts in support of future high-speed supersonic transport aircraft. To extend the capabilities of this testbed vehicle the F-16XL ship 1 aircraft was upgraded with a digital flight control system. The added flexibility of a digital flight control system increases the versatility of this airplane as a testbed for aerodynamic research and investigation of advanced technologies. This report presents the handling qualities flight test results covering the envelope expansion of the F-16XL with the digital flight control system.

  2. Preliminary flight prototype potable water bactericide system

    NASA Technical Reports Server (NTRS)

    Jasionowski, W. J.; Allen, E. T.

    1973-01-01

    The development, design, and testing of a preliminary flight prototype potable water bactericide system are described. The system is an assembly of upgraded canisters composed of: (1) A biological filter; (2) an activated charcoal and ion exchange resin canister; (3) a silver chloride canister, (4) a deionizer, (5) a silver bromide canister with a partial bypass, and (6) mock-up instrumentation and circuitry. The system exhibited bactericidal activity against 10 to the 9th power Pseudomonas aeruginosa and/or Type IIIa, and reduced Bacillus subtilis by up to 5 orders of magnitude in 24 hours at ambient temperatures with a 1 ppm silver ion dose. Four efficacy tests were performed with a AgBr canister dosing anticipated fuel cell water. Tests show that a 0.05 ppm silver ion dose was bactericidal against 3 plus or minus 1 x 10 to the 9th power (5 plus or minus 1 x 10,000/ml Pseudomonas aeruginosa and/or Type IIIa in 15 minutes or less.

  3. Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1

    DOE PAGES

    Kanisauskas, K.; Affolder, A.; Arndt, K.; ...

    2017-02-15

    CMOS active pixel sensors are being investigated for their potential use in the ATLAS inner tracker upgrade at the HL-LHC. The new inner tracker will have to handle a significant increase in luminosity while maintaining a sufficient signal-to-noise ratio and pulse shaping times. This paper focuses on the prototype chip "HVStripV1" (manufactured in the AMS HV-CMOS 350nm process) characterization before and after irradiation up to fluence levels expected for the strip region in the HL-LHC environment. The results indicate an increase of depletion region after irradiation for the same bias voltage by a factor of ≈2.4 and ≈2.8 for twomore » active pixels on the test chip. As a result, there was also a notable increase in noise levels from 85 e – to 386 e – and from 75 e – to 277 e – for the corresponding pixels.« less

  4. Radiation hardness studies of AMS HV-CMOS 350 nm prototype chip HVStripV1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kanisauskas, K.; Affolder, A.; Arndt, K.

    CMOS active pixel sensors are being investigated for their potential use in the ATLAS inner tracker upgrade at the HL-LHC. The new inner tracker will have to handle a significant increase in luminosity while maintaining a sufficient signal-to-noise ratio and pulse shaping times. This paper focuses on the prototype chip "HVStripV1" (manufactured in the AMS HV-CMOS 350nm process) characterization before and after irradiation up to fluence levels expected for the strip region in the HL-LHC environment. The results indicate an increase of depletion region after irradiation for the same bias voltage by a factor of ≈2.4 and ≈2.8 for twomore » active pixels on the test chip. As a result, there was also a notable increase in noise levels from 85 e – to 386 e – and from 75 e – to 277 e – for the corresponding pixels.« less

  5. Construction of a dual axis force reflection stick and test station

    NASA Astrophysics Data System (ADS)

    Repperger, Daniel E.; Scarborough, Eric L.; Chelette, Tamara L.

    1991-11-01

    This report describes the construction of a dual axis force reflecting stick controller and test station which was constructed through the use of basic research funds (ILIR monies). The prototype described in this report is powered only by electric motors and used the latest technology in computers. This was an advancement over a previous prototype which involved pneumatic devices and was very large, bulky, and awkward to use. An experiment was conducted with 5 subjects as described herein to test the overall system for its use in experimental design. The motivation for developing such a small test station for the use of force reflection in stick controllers is because with this new compact and portable system, many new applications now appear for this technology. The system described herein minimizes both weight and electric power requirements to produce the same force reflection. By upgrading the technology in the components used in this test station, wider use of force reflection is now available for a host of new applications.

  6. KSC-2010-5293

    NASA Image and Video Library

    2010-10-21

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller

  7. KSC-2010-5290

    NASA Image and Video Library

    2010-10-21

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller

  8. KSC-2010-5292

    NASA Image and Video Library

    2010-10-21

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller

  9. KSC-2010-5291

    NASA Image and Video Library

    2010-10-21

    CAPE CANAVERAL, Fla. -- At NASA's Kennedy Space Center in Florida, testing of the Tilt-Up Umbilical Arm (TUUA) prototype's Environmental Control System Quick Disconnect takes place in the Launch Equipment Test Facility's 6,000-square-foot high bay. The prototype is used to demonstrate the safe disconnect and retraction of ground umbilical plates and associated hardware of a launch vehicle's upper stage and service module. The Environmental Control System consists of regulated air, which would be used to purge an inner tank and crew module. Since 1977, the facility has supported NASA’s Launch Services, shuttle, International Space Station, and Constellation programs, as well as commercial providers. The facility recently underwent a major upgrade to support even more programs, projects and customers. It houses a cable fabrication and molding shop, pneumatics shop, machine and weld shop and full-scale control room. Outside, the facility features a water flow test loop, vehicle motion simulator, 600-ton test fixture, launch simulation towers and a cryogenic system. Photo credit: NASA/Jack Pfaller

  10. A Novel WA-BPM Based on the Generalized Multistep Scheme in the Propagation Direction in the Waveguide

    NASA Astrophysics Data System (ADS)

    Ji, Yang; Chen, Hong; Tang, Hongwu

    2017-06-01

    A highly accurate wide-angle scheme, based on the generalized mutistep scheme in the propagation direction, is developed for the finite difference beam propagation method (FD-BPM). Comparing with the previously presented method, the simulation shows that our method results in a more accurate solution, and the step size can be much larger

  11. Notification Event Architecture for Traveler Screening: Predictive Traveler Screening Using Event Driven Business Process Management

    ERIC Educational Resources Information Center

    Lynch, John Kenneth

    2013-01-01

    Using an exploratory model of the 9/11 terrorists, this research investigates the linkages between Event Driven Business Process Management (edBPM) and decision making. Although the literature on the role of technology in efficient and effective decision making is extensive, research has yet to quantify the benefit of using edBPM to aid the…

  12. Correlation of arterial fetal base deficit and lactate changes with severity of variable heart rate decelerations in the near-term ovine fetus.

    PubMed

    Ross, Michael G; Jessie, Marquis; Amaya, Kevin; Matushewski, Brad; Durosier, L Daniel; Frasch, Martin G; Richardson, Bryan S

    2013-04-01

    Recent guidelines classify variable decelerations without detail as to degree of depth. We hypothesized that variable deceleration severity is highly correlated with fetal base deficit accumulation. Seven near-term fetal sheep underwent a series of graded umbilical cord occlusions resulting in mild (30 bpm decrease), moderate (60 bpm decrease), or severe (decrease of 90 bpm to baseline <70 bpm) variable decelerations at 2.5 minute intervals. Mild, moderate, and severe variable decelerations increased fetal base deficit (0.21 ± 0.03, 0.27 ± 0.03, and 0.54 ± 0.09 mEq/L per minute) in direct proportion to severity. During recovery, fetal base deficit cleared at 0.12 mEq/L per minute. In this model, ovine fetuses can tolerate repetitive mild and moderate variable decelerations with minimal change in base deficit and lactate. In contrast, repetitive severe variable decelerations may result in significant base deficit increases, dependent on frequency. Modified guideline differentiation of mild/moderate vs severe variable decelerations may aid in the interpretation of fetal heart rate tracings and optimization of clinical management paradigms. Copyright © 2013 Mosby, Inc. All rights reserved.

  13. The Closed Orbit Measurement System at the DELTA Synchrotron Radiation Facility And First Investigations Concerning the Installation of a Beam Based BPM Calibration System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jankowiak, A.; Wille, K.; /Dortmund U. /SLAC

    2011-08-25

    For a synchrotron radiation source it is necessary to operate a monitoring system to determine the beam position with high resolution and accuracy with respect to the axis of the quadrupole magnets. In this paper the present closed orbit measurement system of the DELTA SR-Facility, concerning the hardware setup, data processing and the calibration methods, will be presented. The results of the calibration measurements and the recent operating experience will be discussed. These results show, that the system is close to the design resolution. But the BPM offsets with respect to the magnetic center of the quadrupole magnets turn outmore » to be not acceptable. For some BPMs they are in the order of several 100 micro m. Therefore it was decided to install a beam based BPM calibration system in the near future . This system should allow to determine the BPM offsets relative to the center of the quadrupole magnets for all 40 BPMs. It is planned to install a system in order to change the focussing strength of each quadrupole individually either in a static or dynamic way.« less

  14. Infrared vibrational spectroscopy of [Ru(bpy)2(bpm)]2+ and [Ru(bpy)3]2+ in the excited triplet state.

    PubMed

    Mukuta, Tatsuhiko; Fukazawa, Naoto; Murata, Kei; Inagaki, Akiko; Akita, Munetaka; Tanaka, Sei'ichi; Koshihara, Shin-ya; Onda, Ken

    2014-03-03

    This work involved a detailed investigation into the infrared vibrational spectra of ruthenium polypyridyl complexes, specifically heteroleptic [Ru(bpy)2(bpm)](2+) (bpy = 2,2'-bipyridine and bpm = 2,2'-bipyrimidine) and homoleptic [Ru(bpy)3](2+), in the excited triplet state. Transient spectra were acquired 500 ps after photoexcitation, corresponding to the vibrational ground state of the excited triplet state, using time-resolved infrared spectroscopy. We assigned the observed bands to specific ligands in [Ru(bpy)2(bpm)](2+) based on the results of deuterium substitution and identified the corresponding normal vibrational modes using quantum-chemical calculations. Through this process, the more complex vibrational bands of [Ru(bpy)3](2+) were assigned to normal vibrational modes. The results are in good agreement with the model in which excited electrons are localized on a single ligand. We also found that the vibrational bands of both complexes associated with the ligands on which electrons are little localized appear at approximately 1317 and 1608 cm(-1). These assignments should allow the study of the reaction dynamics of various photofunctional systems including ruthenium polypyridyl complexes.

  15. Biological Parametric Mapping: A Statistical Toolbox for Multi-Modality Brain Image Analysis

    PubMed Central

    Casanova, Ramon; Ryali, Srikanth; Baer, Aaron; Laurienti, Paul J.; Burdette, Jonathan H.; Hayasaka, Satoru; Flowers, Lynn; Wood, Frank; Maldjian, Joseph A.

    2006-01-01

    In recent years multiple brain MR imaging modalities have emerged; however, analysis methodologies have mainly remained modality specific. In addition, when comparing across imaging modalities, most researchers have been forced to rely on simple region-of-interest type analyses, which do not allow the voxel-by-voxel comparisons necessary to answer more sophisticated neuroscience questions. To overcome these limitations, we developed a toolbox for multimodal image analysis called biological parametric mapping (BPM), based on a voxel-wise use of the general linear model. The BPM toolbox incorporates information obtained from other modalities as regressors in a voxel-wise analysis, thereby permitting investigation of more sophisticated hypotheses. The BPM toolbox has been developed in MATLAB with a user friendly interface for performing analyses, including voxel-wise multimodal correlation, ANCOVA, and multiple regression. It has a high degree of integration with the SPM (statistical parametric mapping) software relying on it for visualization and statistical inference. Furthermore, statistical inference for a correlation field, rather than a widely-used T-field, has been implemented in the correlation analysis for more accurate results. An example with in-vivo data is presented demonstrating the potential of the BPM methodology as a tool for multimodal image analysis. PMID:17070709

  16. Analysis of a Novel Diffractive Scanning Wire Beam Position Monitor (BPM) for Discriminative Profiling of Electron Vs. X Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tatchyn, Roman; /SLAC

    2011-09-01

    Recent numerical studies of Free Electron Lasers (FELs) operating in the Self Amplified Spontaneous Emission (SASE) regime indicate a large sensitivity of the gain to the degree of transverse overlap (and associated phase coherence) between the electron and photon beams traveling down the insertion device. Simulations of actual systems imply that accurate detection and correction for this relative loss of overlap, rather than correction for the absolute departure of the electron beam from a fixed axis, is the preferred function of an FEL amplifier's Beam Position Monitor (BPM) and corrector systems. In this note we propose a novel diffractive BPMmore » with the capability of simultaneously detecting and resolving the absolute (and relative) transverse positions and profiles of electron and x-ray beams co-propagating through an undulator. We derive the equations governing the performance of the BPM and examine its predicted performance for the SLAC Linac Coherent Light Source (LCLS), viz., for profiling multi-GeV electron bunches co-propagating with one-to-several-hundred keV x-ray beams. Selected research and development (r&d) tasks for fabricating and testing the proposed BPM are discussed.« less

  17. A novel electromagnetic design and a new manufacturing process for the cavity BPM (Beam Position Monitor)

    NASA Astrophysics Data System (ADS)

    Dal Forno, Massimo; Craievich, Paolo; Baruzzo, Roberto; De Monte, Raffaele; Ferianis, Mario; Lamanna, Giuseppe; Vescovo, Roberto

    2012-01-01

    The Cavity Beam Position Monitor (BPM) is a beam diagnostic instrument which, in a seeded Free Electron Laser (FEL), allows the measurement of the electron beam position in a non-destructive way and with sub-micron resolution. It is composed by two resonant cavities called reference and position cavity, respectively. The measurement exploits the dipole mode that arises when the electron bunch passes off axis. In this paper we describe the Cavity BPM that has been designed and realized in the context of the FERMI@Elettra project [1]. New strategies have been adopted for the microwave design, for both the reference and the position cavities. Both cavities have been simulated by means of Ansoft HFSS [2] and CST Particle Studio [3], and have been realized using high precision lathe and wire-EDM (Electro-Discharge) machine, with a new technique that avoids the use of the sinker-EDM machine. Tuners have been used to accurately adjust the working frequencies for both cavities. The RF parameters have been estimated, and the modifications of the resonant frequencies produced by brazing and tuning have been evaluated. Finally, the Cavity BPM has been installed and tested in the presence of the electron beam.

  18. Design, test, and calibration of an electrostatic beam position monitor

    NASA Astrophysics Data System (ADS)

    Cohen-Solal, Maurice

    2010-03-01

    The low beta of proton or ion beams favors an electrostatic pickup to measure the transverse beam centroid position. Often papers on beam position monitors (BPM) are focused on a particular aspect of the problem; however, it is important to consider all various issues of a position measurement system. Based on our experience at the IPHI (high intensity injector proton) facility at CEA-Saclay, this paper will address all aspects to design, test, and calibrate a BPM for proton linear accelerators, while emphasizing the determination of the absolute beam position. We present details of the readout electronics, and describe the calibration of the BPM using a test station. For calculation and simulation of the electrical signals we developed a Mathematica script. The error analysis presented, on the basis of six BPMs installed in the high energy section of IPHI, demonstrates the expected accuracy of the position measurement. These studies also identify the parameters that could improve the performance of the beam position control. The experience from these developments is currently being used for the BPM design and test stand dedicated to the Spiral2 accelerator at Ganil-Caen which will deliver heavy ion beams.

  19. [Developing a home care nursing information system by utilizing wire-wireless network and mobile computing system].

    PubMed

    Park, Jung-Ho; Park, Sung-Ae; Yoon, Soon-Nyoung; Kang, Sung-Rye

    2004-04-01

    The purpose of this study was to develop a home care nursing network system for operating home care effectively and efficiently by utilizing a wire-wireless network and mobile computing in order to record and send patients' data in real time, and by combining the headquarter office and the local offices with home care nurses over the Internet. It complements the preceding research from 1999 by adding home care nursing standard guidelines and upgrading the PDA program. Method/1 and Prototyping were adopted to develop the main network system. The detailed research process is as follows : 1)home care nursing standard guidelines for Diabetes, cancer and peritoneal-dialysis were added in 12 domains of nursing problem fields with nursing assessment/intervention algorithms. 2) complementing the PDA program was done by omitting and integrating the home care nursing algorithm path which is unnecessary and duplicated. Also, upgrading the PDA system was done by utilizing the machinery and tools where the PDA and the data transmission modem are integrated, CDMX-1X base construction, in order to reduce a transmission error or transmission failure.

  20. The Phase-2 electronics upgrade of the ATLAS liquid argon calorimeter system

    NASA Astrophysics Data System (ADS)

    Vachon, B.

    2018-03-01

    The LHC high-luminosity upgrade in 2024-2026 requires the associated detectors to operate at luminosities about 5-7 times larger than assumed in their original design. The pile-up is expected to increase to up to 200 events per proton bunch-crossing. The current readout of the ATLAS liquid argon calorimeters does not provide sufficient buffering and bandwidth capabilities to accommodate the hardware triggers requirements imposed by these harsh conditions. Furthermore, the expected total radiation doses are beyond the qualification range of the current front-end electronics. For these reasons an almost complete replacement of the front-end and off-detector readout system is foreseen for the 182,468 readout channels. The new readout system will be based on a free-running architecture, where calorimeter signals are amplified, shaped and digitized by on-detector electronics, then sent at 40 MHz to the off-detector electronics for further processing. Results from the design studies on the performance of the components of the readout system are presented, as well as the results of the tests of the first prototypes.

  1. Developments of next generation monitor and control systems for radio telescopes

    NASA Astrophysics Data System (ADS)

    Kodilkar, J.; Uprade, R.; Nayak, S.; Wadadekar, Y.; Chengalur, J.; Gupta, Y.

    2013-04-01

    As part of the ongoing upgrade of the GMRT observatory, the monitor and control (M&C) system is being upgraded to a modern specification driven system. The basic building block of the proposed M&C framework is a SACE node which provides command, response and event data streaming interfaces to the child and parent nodes running locally or remotely in a heterogeneous operating system environment. A prototype M&C system formed by hierarchically composing SACE nodes at different levels has been successfully tested at the GMRT. For the recently built 15m antenna at NCRA, a generic, web based M&C system has been developed which allows remote, authenticated operation. We discuss issues relevant to the development of the next generation M&C systems for radio telescopes using the lessons learned from these two systems. We also summarize flexible, reusable and cost-effective approaches using off the shelf packages and technologies used in generic frameworks, which can contribute to form the basis for M&C systems of very large radio telescopes like the SKA.

  2. (WA80 collaboration, Muenster, W. Germany, April 17--21, 1989): Foreign trip report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Young, G.R.

    1989-05-11

    The traveler attended a WA80 collaboration meeting held at the University of Muenster, FRG. The status of various experimental analyses was reviewed and discussed, as was the status of various papers in preparation. Plans for a joint NA35-WA80 proposal to use the lead beams to be available at the SPS in 1993 were advanced in a meeting which included several WA80 persons plus Reinhard Stock of NA35 and Rudolf Bock of GSI. Plans for a prototype of a high-resolution photon calorimeter were made. ORNL is asked to prepare much of this for a test run in December 1989. Further plansmore » for the 1990 and 1991 extended beam times at CERN with /sup 32/S were made. ORNL is asked to participate in a large upgrade of the present trigger and to collaborate with Muenster in a large upgrade and expansion of the present photon calorimeter. Other items include a rearrangement of the experimental area (GSI), new multiplicity counters (Lund-LBL), and a new data-acquisition system (GSI-Muenster).« less

  3. Upgrading NASA/DOSE laser ranging system control computers

    NASA Technical Reports Server (NTRS)

    Ricklefs, Randall L.; Cheek, Jack; Seery, Paul J.; Emenheiser, Kenneth S.; Hanrahan, William P., III; Mcgarry, Jan F.

    1993-01-01

    Laser ranging systems now managed by the NASA Dynamics of the Solid Earth (DOSE) and operated by the Bendix Field Engineering Corporation, the University of Hawaii, and the University of Texas have produced a wealth on interdisciplinary scientific data over the last three decades. Despite upgrades to the most of the ranging station subsystems, the control computers remain a mix of 1970's vintage minicomputers. These encompass a wide range of vendors, operating systems, and languages, making hardware and software support increasingly difficult. Current technology allows replacement of controller computers at a relatively low cost while maintaining excellent processing power and a friendly operating environment. The new controller systems are now being designed using IBM-PC-compatible 80486-based microcomputers, a real-time Unix operating system (LynxOS), and X-windows/Motif IB, and serial interfaces have been chosen. This design supports minimizing short and long term costs by relying on proven standards for both hardware and software components. Currently, the project is in the design and prototyping stage with the first systems targeted for production in mid-1993.

  4. Beam-based calibrations of the BPM offset at C-ADS Injector II

    NASA Astrophysics Data System (ADS)

    Chen, Wei-Long; Wang, Zhi-Jun; Feng, Chi; Dou, Wei-Ping; Tao, Yue; Jia, Huan; Wang, Wang-Sheng; Liu, Shu-Hui; He, Yuan

    2016-07-01

    Beam-based BPM offset calibration was carried out for Injector II at the C-ADS demonstration facility at the Institute of Modern Physics (IMP), Chinese Academy of Science (CAS). By using the steering coils integrated in the quadrupoles, the beam orbit can be effectively adjusted and BPM positions recorded at the Medium Energy Beam Transport of the Injector II Linac. The studies were done with a 2 mA, 2.1 MeV proton beam in pulsed mode. During the studies, the “null comparison method” was applied for the calibration. This method is less sensitive to errors compared with the traditional transmission matrix method. In addition, the quadrupole magnet’s center can also be calibrated with this method. Supported by National Natural Science Foundation of China (91426303, 11525523)

  5. A novel cuffless device for self-measurement of blood pressure: concept, performance and clinical validation.

    PubMed

    Boubouchairopoulou, N; Kollias, A; Chiu, B; Chen, B; Lagou, S; Anestis, P; Stergiou, G S

    2017-07-01

    A pocket-size cuffless electronic device for self-measurement of blood pressure (BP) has been developed (Freescan, Maisense Inc., Zhubei, Taiwan). The device estimates BP within 10 s using three embedded electrodes and one force sensor that is applied over the radial pulse to evaluate the pulse wave. Before use, basic anthropometric characteristics are recorded on the device, and individualized initial calibration is required based on a standard BP measurement performed using an upper-arm BP monitor. The device performance in providing valid BP readings was evaluated in 313 normotensive and hypertensive adults in three study phases during which the device sensor was upgraded. A formal validation study of a prototype device against mercury sphygmomanometer was performed according to the American National Standards Institute/Association for the Advancement of Medical Instrumentation/International Organization for Standardization (ANSI/AAMI/ISO) 2013 protocol. The test device succeeded in obtaining a valid BP measurement (three successful readings within up to five attempts) in 55-72% of the participants, which reached 87% with device sensor upgrade. For the validation study, 125 adults were recruited and 85 met the protocol requirements for inclusion. The mean device-observers BP difference was 3.2±6.7 (s.d.) mm Hg for systolic and 2.6±4.6 mm Hg for diastolic BP (criterion 1). The estimated s.d. (inter-subject variability) were 5.83 and 4.17 mm Hg respectively (criterion 2). These data suggest that this prototype cuffless BP monitor provides valid self-measurements in the vast majority of adults, and satisfies the BP measurement accuracy criteria of the ANSI/AAMI/ISO 2013 validation protocol.

  6. Prototyping of petalets for the Phase-II upgrade of the silicon strip tracking detector of the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Kuehn, S.; Benítez, V.; Fernández-Tejero, J.; Fleta, C.; Lozano, M.; Ullán, M.; Lacker, H.; Rehnisch, L.; Sperlich, D.; Ariza, D.; Bloch, I.; Díez, S.; Gregor, I.; Keller, J.; Lohwasser, K.; Poley, L.; Prahl, V.; Zakharchuk, N.; Hauser, M.; Jakobs, K.; Mahboubi, K.; Mori, R.; Parzefall, U.; Bernabéu, J.; Lacasta, C.; Marco-Hernandez, R.; Rodriguez Rodriguez, D.; Santoyo, D.; Solaz Contell, C.; Soldevila Serrano, U.; Affolder, T.; Greenall, A.; Gallop, B.; Phillips, P. W.; Cindro, V.

    2018-03-01

    In the high luminosity era of the Large Hadron Collider, the instantaneous luminosity is expected to reach unprecedented values, resulting in about 200 proton-proton interactions in a typical bunch crossing. To cope with the resultant increase in occupancy, bandwidth and radiation damage, the ATLAS Inner Detector will be replaced by an all-silicon system, the Inner Tracker (ITk). The ITk consists of a silicon pixel and a strip detector and exploits the concept of modularity. Prototyping and testing of various strip detector components has been carried out. This paper presents the developments and results obtained with reduced-size structures equivalent to those foreseen to be used in the forward region of the silicon strip detector. Referred to as petalets, these structures are built around a composite sandwich with embedded cooling pipes and electrical tapes for routing the signals and power. Detector modules built using electronic flex boards and silicon strip sensors are glued on both the front and back side surfaces of the carbon structure. Details are given on the assembly, testing and evaluation of several petalets. Measurement results of both mechanical and electrical quantities are shown. Moreover, an outlook is given for improved prototyping plans for large structures.

  7. Recent progress on monolithic fiber amplifiers for next generation of gravitational wave detectors

    NASA Astrophysics Data System (ADS)

    Wellmann, Felix; Booker, Phillip; Hochheim, Sven; Theeg, Thomas; de Varona, Omar; Fittkau, Willy; Overmeyer, Ludger; Steinke, Michael; Weßels, Peter; Neumann, Jörg; Kracht, Dietmar

    2018-02-01

    Single-frequency fiber amplifiers in MOPA configuration operating at 1064 nm (Yb3+) and around 1550 nm (Er3+ or Er3+:Yb3+) are promising candidates to fulfill the challenging requirements of laser sources of the next generation of interferometric gravitational wave detectors (GWDs). Most probably, the next generation of GWDs is going to operate not only at 1064 nm but also at 1550 nm to cover a broader range of frequencies in which gravitational waves are detectable. We developed an engineering fiber amplifier prototype at 1064 nm emitting 215 W of linearly-polarized light in the TEM00 mode. The system consists of three modules: the seed source, the pre-amplifier, and the main amplifier. The modular design ensures reliable long-term operation, decreases system complexity and simplifies repairing and maintenance procedures. It also allows for the future integration of upgraded fiber amplifier systems without excessive downtimes. We also developed and characterized a fiber amplifier prototype at around 1550 nm that emits 100 W of linearly-polarized light in the TEM00 mode. This prototype uses an Er3+:Yb3+ codoped fiber that is pumped off-resonant at 940 nm. The off-resonant pumping scheme improves the Yb3+-to-Er3+ energy transfer and prevents excessive generation of Yb3+-ASE.

  8. Development and test of the DAQ system for a Micromegas prototype to be installed in the ATLAS experiment

    NASA Astrophysics Data System (ADS)

    Bianco, M.; Martoiu, S.; Sidiropoulou, O.; Zibell, A.

    2015-12-01

    A Micromegas (MM) quadruplet prototype with an active area of 0.5 m2 that adopts the general design foreseen for the upgrade of the innermost forward muon tracking systems (Small Wheels) of the ATLAS detector in 2018-2019, has been built at CERN and is going to be tested in the ATLAS cavern environment during the LHC RUN-II period 2015-2017. The integration of this prototype detector into the ATLAS data acquisition system using custom ATCA equipment is presented. An ATLAS compatible Read Out Driver (ROD) based on the Scalable Readout System (SRS), the Scalable Readout Unit (SRU), will be used in order to transmit the data after generating valid event fragments to the high-level Read Out System (ROS). The SRU will be synchronized with the LHC bunch crossing clock (40.08 MHz) and will receive the Level-1 trigger signals from the Central Trigger Processor (CTP) through the TTCrx receiver ASIC. The configuration of the system will be driven directly from the ATLAS Run Control System. By using the ATLAS TDAQ Software, a dedicated Micromegas segment has been implemented, in order to include the detector inside the main ATLAS DAQ partition. A full set of tests, on the hardware and software aspects, is presented.

  9. Heart Rates of High School Physical Education Students during Team Sports, Individual Sports, and Fitness Activities

    ERIC Educational Resources Information Center

    Laurson, Kelly R.; Brown, Dale D.; Cullen, Robert W.; Dennis, Karen K.

    2008-01-01

    This study examined how activity type influenced heart rates and time spent in target heart rate zones of high school students participating in physical education classes. Significantly higher average heart rates existed for fitness (142 plus or minus 24 beats per minute [bpm]) compared to team (118 plus or minus 24 bpm) or individual (114 plus or…

  10. Ultraviolet carbon lines in the spectrum of the white dwarf BPM 11668

    NASA Technical Reports Server (NTRS)

    Wegner, G.

    1983-01-01

    The southern hemisphere DC white dwarf BPM 11668 has been found to show strong ultraviolet lines of neutral carbon using observations from the IUE satellite. This star seems typical of the growing number of DC white dwarfs found to be of this type and appears to have a carbon abundance near C:He = 0.0001, with an effective temperature of 8500 K.

  11. Bipedal hopping timed to a metronome to detect impairments in anticipatory motor control in people with mild multiple sclerosis.

    PubMed

    Kirkland, Megan C; Chen, Alice; Downer, Matthew B; Holloway, Brett J; Wallack, Elizabeth M; Lockyer, Evan J; Buckle, Natasha C M; Abbott, Courtney L; Ploughman, Michelle

    2018-06-01

    People with mild multiple sclerosis (MS) often report subtle deficits in balance and cognition but display no measurable impairment on clinical assessments. We examined whether hopping to a metronome beat had the potential to detect anticipatory motor control deficits among people with mild MS (Expanded Disability Status Scale ≤ 3.5). Participants with MS (n = 13), matched controls (n = 9), and elderly subjects (n = 13) completed tests of cognition (Montreal Cognitive Assessment (MoCA)) and motor performance (Timed 25 Foot Walk Test (T25FWT)). Participants performed two bipedal hopping tasks: at 40 beats/min (bpm) and 60-bpm in random order. Hop characteristics (length, symmetry, variability) and delay from the metronome beat were extracted from an instrumented walkway and compared between groups. The MS group became more delayed from the metronome beat over time whereas elderly subjects tended to hop closer to the beat (F = 4.52, p = 0.02). Delay of the first hop during 60-bpm predicted cognition in people with MS (R = 0.55, β = 4.64 (SD 4.63), F = 4.85, p = 0.05) but not among control (R = 0.07, p = 0.86) or elderly subjects (R = 0.17, p = 0.57). In terms of hopping characteristics, at 60-bpm, people with MS and matched controls were significantly different from the elderly group. However, at 40-bpm, the MS group was no longer significantly different from the elderly group, even though matched controls and elderly still differed significantly. This new timed hopping test may be able to detect both physical ability, and feed-forward anticipatory control impairments in people with mild MS. Hopping at a frequency of 40-bpm seemed more challenging. Several aspects of anticipatory motor control can be measured: including reaction time to the first metronome cue and the ability to adapt and anticipate the beat over time. Crown Copyright © 2018. Published by Elsevier Ltd. All rights reserved.

  12. Sex Differences in Cardiac Baroreflex Sensitivity after Isometric Handgrip Exercise.

    PubMed

    Teixeira, André L; Ritti-Dias, Raphael; Antonino, Diego; Bottaro, Martim; Millar, Philip J; Vianna, Lauro C

    2018-04-01

    This study aimed to investigate potential sex-related differences on spontaneous cardiac baroreflex sensitivity (cBRS) after acute isometric handgrip (IHG) exercise. Twenty men (age, 23 ± 3 yr) and 20 women (age, 24 ± 4 yr) randomly performed four sets of 2-min IHG exercise (two sets for each limb) at 30% maximal voluntary contraction (experimental) or 3% maximal voluntary contraction (sham). Beat-to-beat heart rate (HR) and arterial blood pressure (BP) were monitored using finger photoplethysmography before and 10, 20, and 30 min after IHG. Spontaneous cBRS was assessed via the sequence technique and cardiac autonomic modulation via time- and frequency-domain HR variability. After IHG, spontaneous cBRS increased during 10 min of recovery in men (Δ13% ± 5%, P = 0.03 vs rest) and increased further in women (Δ23% ± 4%, P < 0.01 vs rest; P = 0.04 vs men). During 20 and 30 min of recovery, cBRS returned to baseline in men but remained elevated in women. HR decreased 10 min after IHG in men (10 min: Δ-2 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-1 ± 1 bpm, P = 0.39 vs rest; 30 min: Δ1 ± 1 bpm, P = 0.31 vs rest) and throughout recovery in women (10 min: Δ-5 ± 1 bpm, P < 0.01 vs rest; 20 min: Δ-3 ± 1 bpm, P < 0.01 vs rest; 30 min: Δ-2 ± 1 bpm, P < 0.01 vs rest). Systolic BP increased 10 min after IHG and remained elevated during 20 min and 30 min in men (P < 0.05). In women, systolic BP increased during 10 min (P < 0.01) and returned to baseline during 20 and 30 min of recovery. Time-domain HR variability (root mean square of successive differences) was increased during recovery in men and women (P < 0.05). Sham had no effect on any variables. Acute IHG exercise increases cBRS and cardiac vagal activity in healthy young subjects, but the magnitude and the time course of changes in cBRS differ between men and women.

  13. Impact of heart rate in atrial fibrillation versus sinus rhythm on mortality in octogenarian patients with acute coronary syndrome

    PubMed Central

    Li, Shijun; Barywani, Salim; Fu, Michael

    2017-01-01

    Introduction Association of heart rate (HR) with mortality in patients with acute coronary syndrome (ACS) and aged ≥ 80 years are underrepresented in clinical trials. We therefore aimed to investigate the association of HR in atrial fibrillation (AF) versus sinus rhythm (SR) with all-cause mortality in octogenarian patients with ACS. Methods A total of 336 patients with ACS patients and aged ≥ 80 years were enrolled into the current study. The end point of interest was death from any cause. Association of HR in AF versus SR with mortality was analyzed by Kaplan-Meier curve following log-rank test and multivariable Cox regression analysis. Results In total, 63 (87.5%) of patients with AF were dead and 147 (59.8%) of patients with SR were dead during the follow-up period. The best cut-off was 80 bpm, with a sensitivity of 62% and specificity of 66%. HR ≤ 80 bpm in SR but not in AF was associated with better outcome as compared with HR > 80 bpm (Chi-Square = 26.55, Log rank P < 0.001). In SR subgroup, the hazard ratios of HR ≤ 80 bpm were 0.51(95% CI 0.37-0.70, P < 0.001) adjusted for age, 0.46 (95%CI 0.33-0.63, P < 0.001) adjusted for gender, 0.62 (95%CI 0.42- 0.93, P = 0.020) adjusted for multivariables respectively. In AF subgroup, the hazard ratios of HR ≤ 80 bpm were 0.83(95% CI 0.49-1.38, P = 0.464) adjusted for age, 0.96 (95%CI 0.59-1.58, P = 0.882) adjusted for gender, 0.72(95% CI 0.41-1.26, P = 0.249) adjusted for multivariables respectively. Conclusion The current study demonstrates that heart rate is an independent prognostic predictor for all-cause mortality, and HR ≤ 80 bpm is associated with improved outcome in SR but not in AF in octogenarian patients with ACS. PMID:29255559

  14. Tests with beam setup of the TileCal phase-II upgrade electronics

    NASA Astrophysics Data System (ADS)

    Reward Hlaluku, Dingane

    2017-09-01

    The LHC has planned a series of upgrades culminating in the High Luminosity LHC which will have an average luminosity 5-7 times larger than the nominal Run-2 value. The ATLAS Tile calorimeter plans to introduce a new readout architecture by completely replacing the back-end and front-end electronics for the High Luminosity LHC. The photomultiplier signals will be fully digitized and transferred for every bunch crossing to the off-detector Tile PreProcessor. The Tile PreProcessor will further provide preprocessed digital data to the first level of trigger with improved spatial granularity and energy resolution in contrast to the current analog trigger signals. A single super-drawer module commissioned with the phase-II upgrade electronics is to be inserted into the real detector to evaluate and qualify the new readout and trigger concepts in the overall ATLAS data acquisition system. This new super-drawer, so-called hybrid Demonstrator, must provide analog trigger signals for backward compatibility with the current system. This Demonstrator drawer has been inserted into a Tile calorimeter module prototype to evaluate the performance in the lab. In parallel, one more module has been instrumented with two other front-end electronics options based on custom ASICs (QIE and FATALIC) which are under evaluation. These two modules together with three other modules composed of the current system electronics were exposed to different particles and energies in three test-beam campaigns during 2015 and 2016.

  15. Electromechanical wave imaging of biologically and electrically paced canine hearts in vivo.

    PubMed

    Costet, Alexandre; Provost, Jean; Gambhir, Alok; Bobkov, Yevgeniy; Danilo, Peter; Boink, Gerard J J; Rosen, Michael R; Konofagou, Elisa E

    2014-01-01

    Electromechanical wave imaging (EWI) has been show capable of directly and entirely non-invasively mapping the trans mural electromechanical activation in all four cardiac chambers in vivo. In this study, we assessed EWI repeatability and reproducibility, as well as its capability of localizing electronic and, for the first time, biological pacing locations in closed-chest, conscious canines. Electromechanical activation was obtained in six conscious animals during normal sinus rhythm (NSR) and idioventricular rhythms occurring in dogs with complete heart block instrumented with electronic and biologic pacemakers (EPM and BPM respectively). After atrioventricular node ablation, dogs were implanted with an EPM in the right ventricular (RV) endocardial apex (n = 4) and two additionally received a BPM at the left ventricular (LV) epicardial base (n = 2). EWI was performed trans thoracically during NSR, BPM and EPM pacing, in conscious dogs, using an unfocused transmit sequence at 2000 frames/s. During NSR, the EW originated at the right atrium (RA), propagated to the left atrium (LA) and emerged from multiple sources in both ventricles. During EPM, the EW originated at the RV apex and propagated throughout both ventricles. During BPM, the EW originated from the LV basal lateral wall and subsequently propagated throughout the ventricles. EWI differentiated BPM from EPM and NSR and identified the distinct pacing origins. Isochrone comparison indicated that EWI was repeatable and reliable. These findings thus indicate the potential for EWI to serve as a simple, non-invasive and direct imaging technology for mapping and characterizing arrhythmias as well as the treatments thereof. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  16. Taurine supplementation improves economy of movement in the cycle test independently of the detrimental effects of ethanol.

    PubMed

    Paulucio, Dailson; Costa, Bruno M; Santos, Caleb G M; Nogueira, Fernando; Koch, Alexander; Machado, Marco; Velasques, Bruna; Ribeiro, Pedro; Pompeu, Fernando Ams

    2017-12-01

    Taurine (TA) ingestion has been touted as blunting the deleterious effects of ethanol (ET) ingestion on motor performance. This study investigated the effects of ingestion of 0.6 mL·kg -1 of ET, 6 grams of TA, and ethanol in combination with taurine (ET+TA) on economy of movement (EM) and heart rate (HR). Nine volunteers, five female (22 ± 3 years) and four male (26 ± 5 years), participated in a study that used a counterbalanced experimental design. EM and HR were measured for 6 min while the subjects were pedalling at a fixed load 10% below the anaerobic threshold. The blood alcohol concentration (BAC) was similar between ET and ET+TA treatments at 30 min after ingestion and after exercise (12.3 mmol·L -1 vs. 13.7 mmol·L -1 , and 9.7 mmol • L -1 vs 10.9 mmol·L -1 , respectively). EM was significantly different among treatments, with lower mL·W -1 following ingestion of TA (-7.1%, p<0.001) than placebo and ET+TA (-2.45%, p=0.001) compared to ET. HR (bpm) was significantly (p<0.05) higher for ET (137 ± 14 bpm) than the other three treatments (placebo = 129 ± 14 bpm; TA = 127 ± 11 bpm; TA+ET = 133 ± 12 and ET = 137 ± 14 bpm). Taurine improved EM when compared to placebo or ET, and reduced HR when compared to ET. The combination of ET+TA also enhanced EM compared to placebo, and reduced HR in comparison to ET alone. Therefore, these findings indicate that taurine improves EM and counteracts ethanol-induced increases in HR during submaximal exercise.

  17. Validation of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the European Society of Hypertension International Protocol revision 2010.

    PubMed

    Kang, Yuan-Yuan; Zeng, Wei-Fang; Liu, Ming; Li, Yan; Wang, Ji-Guang

    2014-02-01

    The present study aimed to evaluate the accuracy of the AVITA BPM63S upper arm blood pressure monitor for home blood pressure monitoring according to the International Protocol of the European Society of Hypertension revision 2010. Systolic and diastolic blood pressures were sequentially measured in 33 adult Chinese (14 women, mean age of 47 years) using a mercury sphygmomanometer (two observers) and the AVITA BPM63S device (one supervisor). Ninety-nine pairs of comparisons were obtained from 33 participants for judgments in two parts with three grading phases. All the blood pressure requirements were fulfilled. The AVITA BPM63S device achieved the targets in part 1 of the validation study. The number of absolute differences between device and observers within 5, 10, and 15 mmHg was 68/99, 89/99, and 96/99, respectively, for systolic blood pressure, and 75/99, 95/99, and 97/99, respectively, for diastolic blood pressure. The device also achieved the criteria in part 2 of the validation study. Twenty-four and 25 participants for systolic and diastolic blood pressure, respectively, had at least two of the three device-observers differences within 5 mmHg (required ≥24). One and two participants for systolic and diastolic blood pressure, respectively, had all three device-observers differences greater than 5 mmHg. The AVITA BPM63S automated oscillometric upper arm blood pressure monitor has passed the requirements of the International Protocol revision 2010, and hence can be recommended for blood pressure measurement at home in adults.

  18. Heart rate and outcome in heart failure with reduced ejection fraction: Differences between atrial fibrillation and sinus rhythm-A CIBIS II analysis.

    PubMed

    Mulder, Bart A; Damman, Kevin; Van Veldhuisen, Dirk J; Van Gelder, Isabelle C; Rienstra, Michiel

    2017-09-01

    Heart rate has been associated with prognosis in patients with heart failure with reduced ejection fraction (HFREF) and sinus rhythm; whether this also holds true in patients with atrial fibrillation (AF) is unknown. To evaluate cardiac rhythm and baseline heart rate and the influence of outcome in patients with HFREF enrolled in the Cardiac Insufficiency Bisoprolol Study II. In total, 2539 patients were stratified according to their baseline heart rhythm (AF or sinus rhythm) and into quartiles of heart rate (≤70 bpm, 71-78 bpm, 79-90 bpm, and >90 bpm). The primary outcome was all-cause mortality. Mean follow-up was 1.3 years. Mean age was 61 years, mean left ventricular ejection fraction was 28%, and 80% were male. A total of 521 (21%) patients had AF at baseline. The risk associated with all-cause mortality for each 5 bpm increase in heart rate in patients with sinus rhythm (hazard ratio [HR]: 1.06, 95% confidence interval [CI]: 1.01-1.11, P = 0.012) was significantly different from those with AF (HR: 1.00, 95% CI: 0.94-1.07, P = 0.90, P for interaction = 0.041). The risk associated with higher heart rate in sinus rhythm was primarily attributable to excess risk in the highest quartile (HR: 1.64, 95% CI: 1.18-2.30, P = 0.003). Allocation to bisoprolol did not modify the interaction between heart rate, rhythm and outcome. In HFREF patients with AF, a higher heart rate is not associated with increased event rates in contrast to HFREF patients with sinus rhythm. © 2017 Wiley Periodicals, Inc.

  19. Heart rate at admission is a predictor of in-hospital mortality in patients with acute coronary syndromes: Results from 58 European hospitals: The European Hospital Benchmarking by Outcomes in acute coronary syndrome Processes study.

    PubMed

    Jensen, Magnus T; Pereira, Marta; Araujo, Carla; Malmivaara, Anti; Ferrieres, Jean; Degano, Irene R; Kirchberger, Inge; Farmakis, Dimitrios; Garel, Pascal; Torre, Marina; Marrugat, Jaume; Azevedo, Ana

    2018-03-01

    The purpose of this study was to investigate the relationship between heart rate at admission and in-hospital mortality in patients with ST-segment elevation myocardial infarction (STEMI) and non-ST-segment elevation acute coronary syndrome (NSTE-ACS). Consecutive ACS patients admitted in 2008-2010 across 58 hospitals in six participant countries of the European Hospital Benchmarking by Outcomes in ACS Processes (EURHOBOP) project (Finland, France, Germany, Greece, Portugal and Spain). Cardiogenic shock patients were excluded. Associations between heart rate at admission in categories of 10 beats per min (bpm) and in-hospital mortality were estimated by logistic regression in crude models and adjusting for age, sex, obesity, smoking, hypertension, diabetes, known heart failure, renal failure, previous stroke and ischaemic heart disease. In total 10,374 patients were included. In both STEMI and NSTE-ACS patients, a U-shaped relationship between admission heart rate and in-hospital mortality was found. The lowest risk was observed for heart rates between 70-79 bpm in STEMI and 60-69 bpm in NSTE-ACS; risk of mortality progressively increased with lower or higher heart rates. In multivariable models, the relationship persisted but was significant only for heart rates >80 bpm. A similar relationship was present in both patients with or without diabetes, above or below age 75 years, and irrespective of the presence of atrial fibrillation or use of beta-blockers. Heart rate at admission is significantly associated with in-hospital mortality in patients with both STEMI and NSTE-ACS. ACS patients with admission heart rate above 80 bpm are at highest risk of in-hospital mortality.

  20. Attenuated Heart Rate Recovery After Exercise Testing and Risk of Incident Hypertension in Men.

    PubMed

    Jae, Sae Young; Bunsawat, Kanokwan; Fadel, Paul J; Fernhall, Bo; Choi, Yoon-Ho; Park, Jeong Bae; Franklin, Barry A

    2016-09-01

    Although attenuated heart rate recovery (HRR) and reduced heart rate (HR) reserve to maximal exercise testing are associated with adverse cardiovascular outcomes, their relation to incident hypertension in healthy normotensive populations is unclear. We examined the hypothesis that both attenuated HRR and reduced HR reserve to exercise testing are associated with incident hypertension in men. A total of 1,855 participants were selected comprising of healthy, initially normotensive men who underwent peak or symptom-limited treadmill testing at baseline. HRR was calculated as the difference between peak HR during exercise testing and the HR at 2 minutes after exercise cessation. HR reserve was calculated as the percentage of HR reserve (peak HR - resting HR)/(220 - age - resting HR) × 100. During an average 4-year follow-up, 179 (9.6%) men developed hypertension. Incident hypertension was associated with HRR quartiles (Q1 (<42 (bpm)) 12.5%, Q2 (43-49 bpm) 8.5%, Q3 (50-56 bpm) 9.3%, and Q4 (>57 bpm) 8.3%; P = 0.05 for trend). The relative risk (RR) of the incident hypertension in the slowest HRR quartile vs. the fastest HRR quartile was 1.78 (95% confidence interval (CI): 1.14-2.78) after adjustment for confounders. Every 1 bpm increment in HRR was associated with a 2% (RR 0.98, 95% CI: 0.97-0.99) lower risk of incident hypertension after adjusting for potential confounders. In contrast, reduced HR reserve did not predict the risk of incident hypertension. Slow HRR after exercise testing is independently associated with the development of hypertension in healthy normotensive men. © American Journal of Hypertension, Ltd 2016. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Assessing the utility of bipolar membranes for use in photoelectrochemical water-splitting cells.

    PubMed

    Vargas-Barbosa, Nella M; Geise, Geoffrey M; Hickner, Michael A; Mallouk, Thomas E

    2014-11-01

    Membranes are important in water-splitting solar cells because they prevent crossover of hydrogen and oxygen. Here, bipolar membranes (BPMs) were tested as separators in water electrolysis cells. Steady-state membrane and solution resistances, electrode overpotentials, and pH gradients were measured at current densities relevant to solar photoelectrolysis. Under forward bias conditions, electrodialysis of phosphate buffer ions creates a pH gradient across a BPM. Under reverse bias, the BPM can maintain a constant buffer pH on both sides of the cell, but a large membrane potential develops. Thus, the BPM does not present a viable solution for electrolysis in buffered electrolytes. However, the membrane potential is minimized when the anode and cathode compartments of the cell contain strongly basic and acidic electrolytes, respectively. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Noninvasive monitoring of blood pressure using optical Ballistocardiography and Photoplethysmograph approaches.

    PubMed

    Chen, Zhihao; Yang, Xiufeng; Teo, Ju Teng; Ng, Soon Huat

    2013-01-01

    A new all optical method for long term and continuous blood pressure measurement and monitoring without using cuffs is proposed by using Ballistocardiography (BCG) and Photoplethysmograph (PPG). Based on BCG signal and PPG signal, a time delay between these two signals is obtained to calculate both systolic blood pressure and diastolic blood pressure via linear regression analysis. The fabricated noninvasive blood pressure monitoring device consists of a fiber sensor mat to measure BCG signal and a SpO2 sensor to measure PPG signal. A commercial digital oscillometric blood pressure meter is used to obtain reference values and for calibration. It has been found that by comparing with the reference device, our prototype has typical means and standard deviations of 9+/-5.6 mmHg for systolic blood pressure, 1.8+/-1.3 mmHg for diastolic blood pressure and 0.6+/-0.9 bpm for pulse rate, respectively. If the fiber optic SpO2 probe is used, this new all fiber cuffless noninvasive blood pressure monitoring device will truly be a MRI safe blood pressure measurement and monitoring device.

  3. The Pierce-Blitzstein Photometer - The PBPHOT

    NASA Astrophysics Data System (ADS)

    Ambruster, Carol; Hull, A. B.; Koch, R. H.; Mitchell, R. J.; Smith, R. E.

    2009-01-01

    This report describes the inception, development and extensive use (over 50 years) of the simultaneous 2-source, pulse-counting photometer named after the two astronomers in this paper's title. These men are not, however, the only personalities associated with the lifetime of the photometer from 1952 to 2007 and the contributions of other people are explicitly recognized. The embellishments and upgrades over time of the original conceptions are detailed for both the optical/mechanical/electrical hardware and the software. The opportunities and limitations of the three observing stations where this photometer and its prototypes were tested and functioned and the telescopes upon which they were mounted are also discussed and compared.

  4. The resonant radio-frequency magnetic probe tuned by coaxial cable.

    PubMed

    Sun, B; Huo, W G; Ding, Z F

    2012-08-01

    In this paper, the resonant rf magnetic probe is upgraded by replacing the rotary capacitor in the old version with the series-connected coaxial cable. The numerical calculation and the measurement with the prototype probe show that the rf magnetic probe can achieve resonance at a middle length of the series-connected coaxial cable. The good electrical symmetry of the new rf magnetic probe is ensured by both the identity of series-connected coaxial cables and the new structure of the primary winding. Practical measurements conduced on an rf inductively coupled plasma source demonstrate that performances of the new rf magnetic probe are good.

  5. TAIPAN fibre feed and spectrograph: engineering overview

    NASA Astrophysics Data System (ADS)

    Staszak, Nicholas F.; Lawrence, Jon; Zhelem, Ross; Content, Robert; Churilov, Vladimir; Case, Scott; Brown, Rebecca; Hopkins, Andrew M.; Kuehn, Kyler; Pai, Naveen; Klauser, Urs; Nichani, Vijay; Waller, Lew

    2016-07-01

    TAIPAN will conduct a stellar and galaxy survey of the Southern sky. The TAIPAN positioner is being developed as a prototype for the MANIFEST instrument on the GMT. The TAIPAN Spectrograph is an AAO designed all-refractive 2-arm design that delivers a spectral resolution of R>2000 over the wavelength range 370-870 nm. It is fed by a custom fibre cable from the TAIPAN Starbugs positioner. The design for TAIPAN incorporates 150 optical fibres (with an upgrade path to 300). Presented is an engineering overview of the UKST Fibre Cable design used to support Starbugs, the custom slit design, and the overall design and build plan for the TAIPAN Spectrograph.

  6. Perkinelmer Lamda 950 Measurements in Support of Nasa's Hubble Space Telescope

    NASA Technical Reports Server (NTRS)

    Miller, Kevin H.; Quijada, Manuel A.

    2014-01-01

    We present visible spectroscopy measurements using the PerkinElmer Lambda 950 grating monochromator in support of two projects at NASA Goddard Space Flight Center. The first and primary project to be discussed is the Wide Field Planetary Camera 2 as an upgrade to the Hubble Space Telescope. Numerous optical filters were measured in the visible and near-infrared regions to experimentally vet the theoretical prediction upon which the filters were engineered. The second topic of our presentation will cover the measurement of SNAP prototype filters from three venders (ASAHI, BARR and JDSU) with applications towards NASAs the Joint Dark Energy Mission (JDEM).

  7. Improvement of hospital processes through business process management in Qaem Teaching Hospital: A work in progress.

    PubMed

    Yarmohammadian, Mohammad H; Ebrahimipour, Hossein; Doosty, Farzaneh

    2014-01-01

    In a world of continuously changing business environments, organizations have no option; however, to deal with such a big level of transformation in order to adjust the consequential demands. Therefore, many companies need to continually improve and review their processes to maintain their competitive advantages in an uncertain environment. Meeting these challenges requires implementing the most efficient possible business processes, geared to the needs of the industry and market segments that the organization serves globally. In the last 10 years, total quality management, business process reengineering, and business process management (BPM) have been some of the management tools applied by organizations to increase business competiveness. This paper is an original article that presents implementation of "BPM" approach in the healthcare domain that allows an organization to improve and review its critical business processes. This project was performed in "Qaem Teaching Hospital" in Mashhad city, Iran and consists of four distinct steps; (1) identify business processes, (2) document the process, (3) analyze and measure the process, and (4) improve the process. Implementing BPM in Qaem Teaching Hospital changed the nature of management by allowing the organization to avoid the complexity of disparate, soloed systems. BPM instead enabled the organization to focus on business processes at a higher level.

  8. Hemodynamic variables predict outcome of emergency thoracotomy in the pediatric trauma population.

    PubMed

    Wyrick, Deidre L; Dassinger, Melvin S; Bozeman, Andrew P; Porter, Austin; Maxson, R Todd

    2014-09-01

    Limited data exist regarding indications for resuscitative emergency thoracotomy (ETR) in the pediatric population. We attempt to define the presenting hemodynamic parameters that predict survival for pediatric patients undergoing ETR. We reviewed all pediatric patients (age <18years), entered into the National Trauma Data Bank from 2007 to 2010, who underwent ETR within one hour of ED arrival. Mechanism of injury and hemodynamics were analyzed using Chi squared and Wilcoxon tests. 316 children (70 blunt, 240 penetrating) underwent ETR, 31% (98/316) survived to discharge. Less than 5% of patients survived when presenting SBP was ≤50mmHg or heart rate was ≤70bpm. For blunt injuries there were no survivors with a pulse ≤80bpm or SBP ≤60mmHg. When survivors were compared to nonsurvivors, blood pressure, pulse, and injury type were statistically significant when treated as independent variables and in a logistic regression model. When ETR was performed for SBP ≤50mmHg or for heart rate ≤70bpm less than 5% of patients survived. There were no survivors of blunt trauma when SBP was ≤60mmHg or pulse was ≤80bpm. This review suggests that ETR may have limited benefit in these patients. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor

    PubMed Central

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L.; Minassian, Arpi

    2016-01-01

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. PMID:27138818

  10. Performance of a Nanometer Resolution BPM System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vogel, V; Hayano, H; Honda, Y

    2005-10-14

    International Linear Collider (ILC) interaction region beam sizes and component position stability requirements will be as small as a few nanometers. it is important to the ongoing ILC design effort to demonstrate that these tolerances can be achieved--ideally using beam-based stability measurements. It has been estimated that an RF cavity BPM with modern waveform processing could provide a position measurement resolution of less than one nanometer. Such a system could form the basis of the desired beam-based stability measurement, as well as be used for other specialized purposes. They have developed a high resolution RF cavity BPM and associated electronics.more » A triplet comprised of these BPMs has been installed in the extraction line of the KEK Accelerator Test Facility (ATF) for testing with its ultra-low emittance beam. The three BPMs are rigidly mounted inside an alignment frame on six variable-length struts which can be used to move the BPMs in position and angle. they have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, they have been able to demonstrate a resolution of approximately 20 nm over a dynamic range of {+-} 20 {micro}m. They report on the progress of these ongoing tests.« less

  11. Brevibacillus laterosporus strain BPM3, a potential biocontrol agent isolated from a natural hot water spring of Assam, India.

    PubMed

    Saikia, R; Gogoi, D K; Mazumder, S; Yadav, A; Sarma, R K; Bora, T C; Gogoi, B K

    2011-03-20

    A bacterial strain designated as BPM3 isolated from mud of a natural hot water spring of Nambar Wild Life Sanctuary, Assam, India, strongly inhibited growth of phytopathogenic fungi (Fusarium oxysporum f. sp. ciceri, F. semitectum, Magnaporthe grisea and Rhizoctonia oryzae) and gram-positive bacterium (Staphylococcus aureus). The maximum growth and antagonistic activity was recorded at 30°C, pH 8.5 when starch and peptone were amended as carbon and nitrogen sources, respectively. In greenhouse experiment, this bacterium (BPM3) suppressed blast disease of rice by 30-67% and protected the weight loss by 35-56.5%. The maximum disease protection (67%) and weight loss protection (56.5%) were recorded when the bacterium was applied before 2 days of the pathogen inoculation. Antifungal and antibacterial compounds were isolated from the bacterium which also inhibited the growth of these targeted pathogens. The compounds were purified and on spectroscopic analysis of a purified fraction having R(f) 0.22 which showed strong antifungal and antibacterial activity indicated the presence of C-H, carbonyl group, dimethyl group, -CH(2) and methyl group. The bacterium was characterized by morphological, biochemical and molecular approaches and confirmed that the strain BPM3 is Brevibacillus laterosporus. Copyright © 2010 Elsevier GmbH. All rights reserved.

  12. Doppler radar sensing of fish physiological motion

    NASA Astrophysics Data System (ADS)

    Hafner, Noah

    The monitoring vital of signs for fish is critical for advancing the study of trophic and energetic strategies, distributions and behavior, environmental impact, and aquaculture approaches. Presented here is a new approach for monitoring fish metabolic state without the trauma and stress associated with capture, surgical ECG, or other implanted sensing systems. Original research contributions include analysis for radar operation under water, development of radar systems for aquatic operation, and application of these systems to non invasively sense the heart and gill motion of fish. Tilapia and Sturgeon were studied to test the efficacy across varied fish body shapes and sizes, ranging from 0.1 to 1.3m in snout to tail length. Monitoring experiments were conducted with eleven tilapia and three sturgeons to assess activity level participated in these experiments, the results from which include activity level monitoring (tilapia: still or fidgeting 94% of time observed), ventilation rate (tilapia: 42 bpm, sturgeon: 145 bpm), and heart rate (tilapia: 41 bpm, sturgeon: 35 bpm). Bland-Altman analysis of radar and ECG measured heart rate indicate agreement between the two measurement techniques and the suitability of radar as an alternative to ECG. The initial steps for developing a system for practical application is also presented including designs for radar system miniaturization and discussion on further characterization steps with less constrained environments.

  13. Revisiting the relationship between exercise heart rate and music tempo preference.

    PubMed

    Karageorghis, Costas I; Jones, Leighton; Priest, David-Lee; Akers, Rose I; Clarke, Adam; Perry, Jennifer M; Reddick, Benjamin T; Bishop, Daniel T; Lim, Harry B T

    2011-06-01

    In the present study, we investigated a hypothesized quartic relationship (meaning three inflection points) between exercise heart rate (HR) and preferred music tempo. Initial theoretical predictions suggested a positive linear relationship (Iwanaga, 1995a, 1995b); however, recent experimental work has shown that as exercise HR increases, step changes and plateaus that punctuate the profile of music tempo preference may occur (Karageorghis, Jones, & Stuart, 2008). Tempi bands consisted of slow (95-100 bpm), medium (115-120 bpm), fast (135-140 bpm), and very fast (155-160 bpm) music. Twenty-eight active undergraduate students cycled at exercise intensities representing 40, 50, 60, 70, 80, and 90% of their maximal HR reserve while their music preference was assessed using a 10-point scale. The Exercise Intensity x Music Tempo interaction was significant, F(6.16, 160.05) = 7.08, p < .001, 7,2 = .21, as was the test for both cubic and quartic trajectories in the exercise HR-preferred-music-tempo relationship (p < .001). Whereas slow tempo music was not preferred at any exercise intensity, preference for fast tempo increased, relative to medium and very fast tempo music, as exercise intensity increased. The implications for the prescription of music in exercise and physical activity contexts are discussed.

  14. Time Series Spectroscopic and Photometric Observations of the Massive DAV BPM 37093

    NASA Astrophysics Data System (ADS)

    Nitta, Atsuko; Kepler, S. O.; Chene, Andre–Nicolas; Koester, D.; Provencal, J. L.; Sullivan, D. J.; Chote, Paul; Safeko, Ramotholo; Kanaan, Antonio; Romero, Alejandra; Corti, Mariela; Corti, Mariela; Kilic, Mukremin; Winget, D. E.

    2015-06-01

    BPM 37093 was the first of only a handful of massive (1.05+/-0.05 M⊙; Bergeron 2004;Koester & Allard 2000) white dwarf pulsators discovered (Kanaan et al. 1992). These stars are particularly interesting because the crystallized mass-fraction as a function of mass and temperature is poorly constrained by observation, yet this process adds 1-2 Gyr uncertainty in ages of the oldest white dwarf stars observed and hence, in the ages of associations that contain them (Abrikosov 1960; Kirzhnits 1960; Salpeter 1961). Last year, we discovered that ESO uses BPM 37093 as a standard star and extracted corresponding spectra from the public archive. The data suggested a large variation in the observed hydrogen line profiles that could potentially be due to pulsations, but the measurement did not reach a detection-quality threshold. To further explore this possibility, though, we obtained 4hrs of continuous time series spectroscopy of BPM 37093 with Gemini in the Northern Spring of 2014. We present our preliminary results from these data along with those from the accompanying time series photometric observations we gathered from Mt. John (New Zealand), South African Astronomical Observatory (SAAO), Panchromatic Robotic optical Monitoring and Polarimetry Telescopes (PROMPT) in Chile, and Complejo Astronomico El Leoncito (Argentina) to support the Gemini observations.

  15. Adhesion of glucosyltransferase phase variants to Streptococcus gordonii bacterium-glucan substrata may involve lipoteichoic acid.

    PubMed

    Vickerman, M M; Jones, G W

    1992-10-01

    Growing Streptococcus gordonii Spp+ phase variants, which have normal levels of glucosyltransferase (GTF) activity, use sucrose to promote their accumulation on surfaces by forming a cohesive bacterium-insoluble glucan polymer mass (BPM). Spp- phase variants, which have lower levels of GTF activity, do not form BPMs and do not remain in BPMs formed by Spp+ cells when grown in mixed cultures. To test the hypothesis that segregation of attached Spp+ and unattached Spp- cells was due to differences in adhesiveness, adhesion between washed, [3H]thymidine-labeled cells and preformed BPM substrata was measured. Unexpectedly, the results showed that cells of both phenotypes, as well as GTF-negative cells, attached equally well to preformed BPMs, indicating that attachment to BPMs was independent of cell surface GTF activity. Initial characterization of this binding interaction suggested that a protease-sensitive component on the washed cells may be binding to lipoteichoic acids sequestered in the BPM, since exogenous lipoteichoic acid inhibited adhesion. Surprisingly, the adhesion of both Spp+ and Spp- cells was markedly inhibited in the presence of sucrose, which also released lipoteichoic acid from the BPM. These in vitro findings suggest that, in vivo, sucrose and lipoteichoic acid may modify dental plaque development by enhancing or inhibiting the attachment of additional bacteria.

  16. One elevated bladder pressure measurement may not be enough to diagnose abdominal compartment syndrome.

    PubMed

    Young, Andrew Joseph; Weber, William; Wolfe, Luke; Ivatury, Rao R; Duane, Therese Marie

    2013-02-01

    Bladder pressure measurements (BPMs) are considered a key component in the diagnosis of abdominal compartment syndrome (ACS). The purpose of this observational review was to determine risk factors of ACS and associated mortality with particular focus on the role of BPM. A retrospective trauma registry and chart review was performed on trauma patients from January 2003 through December 2010. Comparisons were made between patients with and without ACS. There were 3172 patients included in the study of whom 46 had ACS. Patients with ACS were younger, more severely injured, with longer lengths of stay. Logistic regression determined Injury Severity Score (ISS) and urinary catheter days as independent predictors of ACS, whereas independent predictors of mortality included age, ISS, and ACS. Subset analysis demonstrated no association between BPM 20 mmHg or greater and diagnosis of ACS versus no ACS. Logistic regression indicated independent predictors of mortality were number of BPM 20 mmHg or greater and age. Patients with ACS are more severely injured with worse outcomes. An isolated BPM 20 mmHg or greater was not associated with ACS and may be inadequate to independently diagnose ACS. These findings suggest the need for repeat measurements with early intervention if they remain elevated in an effort to decrease mortality associated with ACS.

  17. Adhesion of glucosyltransferase phase variants to Streptococcus gordonii bacterium-glucan substrata may involve lipoteichoic acid.

    PubMed Central

    Vickerman, M M; Jones, G W

    1992-01-01

    Growing Streptococcus gordonii Spp+ phase variants, which have normal levels of glucosyltransferase (GTF) activity, use sucrose to promote their accumulation on surfaces by forming a cohesive bacterium-insoluble glucan polymer mass (BPM). Spp- phase variants, which have lower levels of GTF activity, do not form BPMs and do not remain in BPMs formed by Spp+ cells when grown in mixed cultures. To test the hypothesis that segregation of attached Spp+ and unattached Spp- cells was due to differences in adhesiveness, adhesion between washed, [3H]thymidine-labeled cells and preformed BPM substrata was measured. Unexpectedly, the results showed that cells of both phenotypes, as well as GTF-negative cells, attached equally well to preformed BPMs, indicating that attachment to BPMs was independent of cell surface GTF activity. Initial characterization of this binding interaction suggested that a protease-sensitive component on the washed cells may be binding to lipoteichoic acids sequestered in the BPM, since exogenous lipoteichoic acid inhibited adhesion. Surprisingly, the adhesion of both Spp+ and Spp- cells was markedly inhibited in the presence of sucrose, which also released lipoteichoic acid from the BPM. These in vitro findings suggest that, in vivo, sucrose and lipoteichoic acid may modify dental plaque development by enhancing or inhibiting the attachment of additional bacteria. PMID:1398940

  18. Implementation of the ATLAS trigger within the multi-threaded software framework AthenaMT

    NASA Astrophysics Data System (ADS)

    Wynne, Ben; ATLAS Collaboration

    2017-10-01

    We present an implementation of the ATLAS High Level Trigger, HLT, that provides parallel execution of trigger algorithms within the ATLAS multithreaded software framework, AthenaMT. This development will enable the ATLAS HLT to meet future challenges due to the evolution of computing hardware and upgrades of the Large Hadron Collider, LHC, and ATLAS Detector. During the LHC data-taking period starting in 2021, luminosity will reach up to three times the original design value. Luminosity will increase further, to up to 7.5 times the design value, in 2026 following LHC and ATLAS upgrades. This includes an upgrade of the ATLAS trigger architecture that will result in an increase in the HLT input rate by a factor of 4 to 10 compared to the current maximum rate of 100 kHz. The current ATLAS multiprocess framework, AthenaMP, manages a number of processes that each execute algorithms sequentially for different events. AthenaMT will provide a fully multi-threaded environment that will additionally enable concurrent execution of algorithms within an event. This has the potential to significantly reduce the memory footprint on future manycore devices. An additional benefit of the HLT implementation within AthenaMT is that it facilitates the integration of offline code into the HLT. The trigger must retain high rejection in the face of increasing numbers of pileup collisions. This will be achieved by greater use of offline algorithms that are designed to maximize the discrimination of signal from background. Therefore a unification of the HLT and offline reconstruction software environment is required. This has been achieved while at the same time retaining important HLT-specific optimisations that minimize the computation performed to reach a trigger decision. Such optimizations include early event rejection and reconstruction within restricted geometrical regions. We report on an HLT prototype in which the need for HLT-specific components has been reduced to a minimum. Promising results have been obtained with a prototype that includes the key elements of trigger functionality including regional reconstruction and early event rejection. We report on the first experience of migrating trigger selections to this new framework and present the next steps towards a full implementation of the ATLAS trigger.

  19. Advanced ACTPol Low-Frequency Array: Readout and Characterization of Prototype 27 and 39 GHz Transition Edge Sensors

    NASA Astrophysics Data System (ADS)

    Koopman, B. J.; Cothard, N. F.; Choi, S. K.; Crowley, K. T.; Duff, S. M.; Henderson, S. W.; Ho, S. P.; Hubmayr, J.; Gallardo, P. A.; Nati, F.; Niemack, M. D.; Simon, S. M.; Staggs, S. T.; Stevens, J. R.; Vavagiakis, E. M.; Wollack, E. J.

    2018-05-01

    Advanced ACTPol (AdvACT) is a third-generation polarization upgrade to the Atacama Cosmology Telescope, designed to observe the cosmic microwave background (CMB). AdvACT expands on the 90 and 150 GHz transition edge sensor (TES) bolometer arrays of the ACT Polarimeter (ACTPol), adding both high-frequency (HF, 150/230 GHz) and low-frequency (LF, 27/39 GHz) multichroic arrays. The addition of the high- and low-frequency detectors allows for the characterization of synchrotron and spinning dust emission at the low frequencies and foreground emission from galactic dust and dusty star-forming galaxies at the high frequencies. The increased spectral coverage of AdvACT will enable a wide range of CMB science, such as improving constraints on dark energy, the sum of the neutrino masses, and the existence of primordial gravitational waves. The LF array will be the final AdvACT array, replacing one of the MF arrays for a single season. Prior to the fabrication of the final LF detector array, we designed and characterized prototype TES bolometers. Detector geometries in these prototypes are varied in order to inform and optimize the bolometer designs for the LF array, which requires significantly lower noise levels and saturation powers (as low as {˜ } 1 pW) than the higher-frequency detectors. Here we present results from tests of the first LF prototype TES detectors for AdvACT, including measurements of the saturation power, critical temperature, thermal conductance, and time constants. We also describe the modifications to the time-division SQUID readout architecture compared to the MF and HF arrays.

  20. Lattice Calibration with Turn-By-Turn BPM Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Xiaobiao; /SLAC; Sebek, James

    2012-07-02

    Turn-by-turn beam position monitor (BPM) data from multiple BPMs are fitted with a tracking code to calibrate magnet strengths in a manner similar to the well known LOCO code. Simulation shows that this turn-by-turn method can be a quick and efficient way for optics calibration. The method is applicable to both linacs and ring accelerators. Experimental results for a section of the SPEAR3 ring is also shown.

  1. Formic acid acting as an efficient oxygen scavenger in four-electron reduction of oxygen catalyzed by a heterodinuclear iridium-ruthenium complex in water.

    PubMed

    Fukuzumi, Shunichi; Kobayashi, Takeshi; Suenobu, Tomoyoshi

    2010-09-01

    A heterodinuclear iridium-ruthenium complex [Ir(III)(Cp*)(H(2)O)(bpm)Ru(II)(bpy)(2)](SO(4))(2) (Cp* = eta(5)-pentamethyl-cyclopentadienyl, bpm = 2,2'-bipyrimidine, bpy = 2,2'-bipyridine) acts as an effective catalyst for removal of dissolved O(2) by the four-electron reduction of O(2) with formic acid in water at an ambient temperature.

  2. Beam Position Monitoring in the CSU Accelerator Facility

    NASA Astrophysics Data System (ADS)

    Einstein, Joshua; Vankeuren, Max; Watras, Stephen

    2014-03-01

    A Beam Position Monitoring (BPM) system is an integral part of an accelerator beamline, and modern accelerators can take advantage of newer technologies and designs when creating a BPM system. The Colorado State University (CSU) Accelerator Facility will include four stripline detectors mounted around the beamline, a low-noise analog front-end, and digitization and interface circuitry. The design will support a sampling rate greater than 10 Hz and sub-100 μm accuracy.

  3. Constraining the physics of carbon crystallization through pulsations of a massive DAV BPM37093

    NASA Astrophysics Data System (ADS)

    Nitta, Atsuko; Kepler, S. O.; Chené, André-Nicolas; Koester, D.; Provencal, J. L.; Kleinmani, S. J.; Sullivan, D. J.; Chote, Paul; Sefako, Ramotholo; Kanaan, Antonio; Romero, Alejandra; Corti, Mariela; Kilic, Mukremin; Montgomery, M. H.; Winget, D. E.

    We are trying to reduce the largest uncertainties in using white dwarf stars as Galactic chronometers by understanding the details of carbon crystalliazation that currently result in a 1-2 Gyr uncertainty in the ages of the oldest white dwarf stars. We expect the coolest white dwarf stars to have crystallized interiors, but theory also predicts hotter white dwarf stars, if they are massive enough, will also have some core crystallization. BPM 37093 is the first discovered of only a handful of known massive white dwarf stars that are also pulsating DAV, or ZZ Ceti, variables. Our approach is to use the pulsations to constrain the core composition and amount of crystallization. Here we report our analysis of 4 hours of continuous time series spectroscopy of BPM 37093 with Gemini South combined with simultaneous time-series photometry from Mt. John (New Zealand), SAAO, PROMPT, and Complejo Astronomico El Leoncito (CASLEO, Argentina).

  4. Constrained independent component analysis approach to nonobtrusive pulse rate measurements

    NASA Astrophysics Data System (ADS)

    Tsouri, Gill R.; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K.

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  5. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-06-22

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test themore » digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.« less

  6. Best practicable means (BPM) and as low as reasonably practicable (ALARP) in action at Sellafield.

    PubMed

    Morley, Bob

    2004-03-01

    Operators within the UK nuclear industry are required to employ 'best practicable means' (BPM) to control and minimise radioactive discharges. The requirement for the use of BPM is in order to ensure that doses from discharges are as low as reasonably practicable (ALARP). This facet is increasingly becoming the principal feature of discharge authorisations issued by the Environment Agencies under the Radioactive Substances Act, 1993 (RSA 93), which are enforceable by law. It is important to state at the outset, however, that scientific assessments to date indicate that there are no expectations of environmental harm from authorised discharges, even where those discharges have historically been up to two orders of magnitude higher than current levels. There is also no evidence to indicate that foreseeable future discharges from the Sellafield site will make any contribution to environmental harm.

  7. Analytical expression for position sensitivity of linear response beam position monitor having inter-electrode cross talk

    NASA Astrophysics Data System (ADS)

    Kumar, Mukesh; Ojha, A.; Garg, A. D.; Puntambekar, T. A.; Senecha, V. K.

    2017-02-01

    According to the quasi electrostatic model of linear response capacitive beam position monitor (BPM), the position sensitivity of the device depends only on the aperture of the device and it is independent of processing frequency and load impedance. In practice, however, due to the inter-electrode capacitive coupling (cross talk), the actual position sensitivity of the device decreases with increasing frequency and load impedance. We have taken into account the inter-electrode capacitance to derive and propose a new analytical expression for the position sensitivity as a function of frequency and load impedance. The sensitivity of a linear response shoe-box type BPM has been obtained through simulation using CST Studio Suite to verify and confirm the validity of the new analytical equation. Good agreement between the simulation results and the new analytical expression suggest that this method can be exploited for proper designing of BPM.

  8. Effect of the type of ion exchange membrane on performance, ion transport, and pH in biocatalyzed electrolysis of wastewater.

    PubMed

    Rozendal, R A; Sleutels, T H J A; Hamelers, H V M; Buisman, C J N

    2008-01-01

    Previous studies have shown that the application of cation exchange membranes (CEMs) in bioelectrochemical systems running on wastewater can cause operational problems. In this paper the effect of alternative types of ion exchange membrane is studied in biocatalyzed electrolysis cells. Four types of ion exchange membranes are used: (i) a CEM, (ii) an anion exchange membrane (AEM), (iii) a bipolar membrane (BPM), and (iv) a charge mosaic membrane (CMM). With respect to the electrochemical performance of the four biocatalyzed electrolysis configurations, the ion exchange membranes are rated in the order AEM > CEM > CMM > BPM. However, with respect to the transport numbers for protons and/or hydroxyl ions (t(H/OH)) and the ability to prevent pH increase in the cathode chamber, the ion exchange membranes are rated in the order BPM > AEM > CMM > CEM.

  9. Syncope During Competitive Events: Interrogating Heart Rate Monitor Watches May Be Useful!

    PubMed

    Thabouillot, Oscar; Bostanci, Kevin; Bouvier, Francois; Dumitrescu, Nicolae; Stéfuriac, Maria; Paule, Philippe; Roche, Nicolas-Charles

    2017-12-01

    This is a case report of a 45-year-old man who reported complete amnesia during the very first kilometer of a 10-km run. He was wearing a heart rate monitor (HRM). The interrogation of his HRM watch showed 200 bpm tachycardia beginning in the first kilometer and increasing up to 220 bpm during the last kilometer. The patient was asked to wear a Holter-monitor (Holter Research Laboratory; Helena, Montana USA) electrocardiogram (ECG) while practicing a training session. This examination allowed for the diagnosis of an adrenergic paroxysmal atrial fibrillation (AF) with an impressive auriculo-ventricular conduction over 260 bpm. This case highlights that non-medical devices, such as connected watches, can be helpful to diagnose arrhythmias. Thabouillot O , Bostanci K , Bouvier F , Dumitrescu N , Stéfuriac M , Paule P , Roche NC . Syncope during competitive events: interrogating heart rate monitor watches may be useful! Prehosp Disaster Med. 2017;32(6):691-693.

  10. Effects of hot-iron branding on heart rate, breathing rate and behaviour of anaesthetised Steller sea lions.

    PubMed

    Walker, K A; Mellish, J E; Weary, D M

    2011-10-01

    This study assessed the heart rate, breathing rate and behavioural responses of 12 juvenile Steller sea lions during hot-iron branding under isoflurane anaesthesia. Physiological and behavioural measures were recorded in four periods: baseline (five minutes), sham branding (one minute), branding (approximately 2.7 minutes) and postbranding (five minutes). No difference in heart rate was noted from baseline to sham branding, but heart rate increased from mean (sem) 78.3 (2.4) bpm in the baseline period to 85.6 (2.5) bpm in the branding period. Heart rate remained elevated in the postbranding period, averaging 84.7 (2.5) bpm. Breathing rate averaged 2.5 (1.0) breaths/minute in the baseline and sham branding periods increased to 8.9 (1.0) breaths/minute during branding, but returned to baseline by the postbranding period. Behaviourally, half of the sea lions exhibited trembling and head and shoulder movements during branding.

  11. BPM analysis of all-optical fiber interferometric sensor based on a U-shape microcavity

    NASA Astrophysics Data System (ADS)

    Wu, Hongbin; Yuan, Lei; Wang, Sumei; Zhao, Longjiang; Cao, Zhitao

    2014-02-01

    Reflectivity spectrum of beam propagation method (BPM), for the first time to the best of our knowledge, is realized and utilized to model all-optical fiber interferometric sensor formed by a U-shape microcavity embedded in a single mode optical fiber and illustrate the principle of sensor structures varied by the length and the depth of U-shape microcavity. BPM analysis gives a constructive guideline to get a high interferometric fringe visibility which is most important for sensing application. The simulated results are completely in agreement with the interferometric sensor principle of Fabry-Perot interferometer (FPI) theory. With the conclusion of FPI sensor, refractive index (RI) sensitivity and temperature sensitivity are then simulated and obtained as 1049+/-5.2nm/RIU (refractive index unit) within RI range of solutions and 1.04+/-0.03pm/°C respectively.

  12. Design of the 15 GHz BPM test bench for the CLIC test facility to perform precise stretched-wire RF measurements

    NASA Astrophysics Data System (ADS)

    Zorzetti, Silvia; Fanucci, Luca; Galindo Muñoz, Natalia; Wendt, Manfred

    2015-09-01

    The Compact Linear Collider (CLIC) requires a low emittance beam transport and preservation, thus a precise control of the beam orbit along up to 50 km of the accelerator components in the sub-μm regime is required. Within the PACMAN3 (Particle Accelerator Components Metrology and Alignment to the Nanometer Scale) PhD training action a study with the objective of pre-aligning the electrical centre of a 15 GHz cavity beam position monitor (BPM) to the magnetic centre of the main beam quadrupole is initiated. Of particular importance is the design of a specific test bench to study the stretched-wire setup for the CLIC Test Facility (CTF3) BPM, focusing on the aspects of microwave signal excitation, transmission and impedance-matching, as well as the mechanical setup and reproducibility of the measurement method.

  13. Constrained independent component analysis approach to nonobtrusive pulse rate measurements.

    PubMed

    Tsouri, Gill R; Kyal, Survi; Dianat, Sohail; Mestha, Lalit K

    2012-07-01

    Nonobtrusive pulse rate measurement using a webcam is considered. We demonstrate how state-of-the-art algorithms based on independent component analysis suffer from a sorting problem which hinders their performance, and propose a novel algorithm based on constrained independent component analysis to improve performance. We present how the proposed algorithm extracts a photoplethysmography signal and resolves the sorting problem. In addition, we perform a comparative study between the proposed algorithm and state-of-the-art algorithms over 45 video streams using a finger probe oxymeter for reference measurements. The proposed algorithm provides improved accuracy: the root mean square error is decreased from 20.6 and 9.5 beats per minute (bpm) for existing algorithms to 3.5 bpm for the proposed algorithm. An error of 3.5 bpm is within the inaccuracy expected from the reference measurements. This implies that the proposed algorithm provided performance of equal accuracy to the finger probe oximeter.

  14. Performance of a high resolution cavity beam position monitor system

    NASA Astrophysics Data System (ADS)

    Walston, Sean; Boogert, Stewart; Chung, Carl; Fitsos, Pete; Frisch, Joe; Gronberg, Jeff; Hayano, Hitoshi; Honda, Yosuke; Kolomensky, Yury; Lyapin, Alexey; Malton, Stephen; May, Justin; McCormick, Douglas; Meller, Robert; Miller, David; Orimoto, Toyoko; Ross, Marc; Slater, Mark; Smith, Steve; Smith, Tonee; Terunuma, Nobuhiro; Thomson, Mark; Urakawa, Junji; Vogel, Vladimir; Ward, David; White, Glen

    2007-07-01

    It has been estimated that an RF cavity Beam Position Monitor (BPM) could provide a position measurement resolution of less than 1 nm. We have developed a high resolution cavity BPM and associated electronics. A triplet comprised of these BPMs was installed in the extraction line of the Accelerator Test Facility (ATF) at the High Energy Accelerator Research Organization (KEK) for testing with its ultra-low emittance beam. The three BPMs were each rigidly mounted inside an alignment frame on six variable-length struts which could be used to move the BPMs in position and angle. We have developed novel methods for extracting the position and tilt information from the BPM signals including a robust calibration algorithm which is immune to beam jitter. To date, we have demonstrated a position resolution of 15.6 nm and a tilt resolution of 2.1 μrad over a dynamic range of approximately ±20 μm.

  15. Model-independent analysis of the Fermilab Tevatron turn-by-turn beam position monitor measurements

    NASA Astrophysics Data System (ADS)

    Petrenko, A. V.; Valishev, A. A.; Lebedev, V. A.

    2011-09-01

    Coherent transverse beam oscillations in the Tevatron were analyzed with the model-independent analysis (MIA) technique. This allowed one to obtain the model-independent values of coupled betatron amplitudes, phase advances, and dispersion function around the ring from a single dipole kick measurement. In order to solve the MIA mode mixing problem which limits the accuracy of determination of the optical functions, we have developed a new technique of rotational MIA mode untangling. The basic idea is to treat each beam position monitor (BPM) as two BPMs separated in a ring by exactly one turn. This leads to a simple criterion of MIA mode separation: the betatron phase advance between any BPM and its counterpart shifted by one turn should be equal to the betatron tune and therefore should not depend on the BPM position in the ring. Furthermore, we describe a MIA-based technique to locate vibrating magnets in a storage ring.

  16. The Effect of Physical Resistance Training on Baroreflex Sensitivity of Hypertensive Rats.

    PubMed

    Gomes, Moisés Felipe Pereira; Borges, Mariana Eiras; Rossi, Vitor de Almeida; Moura, Elizabeth de Orleans C de; Medeiros, Alessandra

    2017-01-01

    Baroreceptors act as regulators of blood pressure (BP); however, its sensitivity is impaired in hypertensive patients. Among the recommendations for BP reduction, exercise training has become an important adjuvant therapy in this population. However, there are many doubts about the effects of resistance exercise training in this population. To evaluate the effect of resistance exercise training on BP and baroreceptor sensitivity in spontaneously hypertensive rats (SHR). Rats SHR (n = 16) and Wistar (n = 16) at 8 weeks of age, at the beginning of the experiment, were randomly divided into 4 groups: sedentary control (CS, n = 8); trained control (CT, n = 8); sedentary SHR (HS, n = 8) and trained SHR (HT, n = 8). Resistance exercise training was performed in a stairmaster-type equipment (1.1 × 0.18 m, 2 cm between the steps, 80° incline) with weights attached to their tails, (5 days/week, 8 weeks). Baroreceptor reflex control of heart rate (HR) was tested by loading/unloading of baroreceptors with phenylephrine and sodium nitroprusside. Resistance exercise training increased the soleus muscle mass in SHR when compared to HS (HS 0.027 ± 0.002 g/mm and HT 0.056 ± 0.003 g/mm). Resistance exercise training did not alter BP. On the other hand, in relation to baroreflex sensitivity, bradycardic response was improved in the TH group when compared to HS (HS -1.3 ± 0.1 bpm/mmHg and HT -2.6 ± 0.2 bpm/mmHg) although tachycardia response was not altered by resistance exercise (CS -3.3 ± 0.2 bpm/mmHg, CT -3.3 ± 0.1 bpm/mmHg, HS -1.47 ± 0.06 bpm/mmHg and HT -1.6 ± 0.1 bpm/mmHg). Resistance exercise training was able to promote improvements on baroreflex sensitivity of SHR rats, through the improvement of bradycardic response, despite not having reduced BP. Os barorreceptores atuam como reguladores da pressão arterial (PA); no entanto, sua sensibilidade encontra-se prejudicada em pacientes hipertensos. Dentre as recomendações para a redução da PA, o treinamento físico tem se tornado um importante adjunto na terapia dessa população. Porém, ainda há diversos questionamentos sobre os efeitos de treinamento físico resistido nessa população. Avaliar o efeito do treinamento físico resistido na PA e na sensibilidade de barorreceptores em ratos espontaneamente hipertensos (SHR). Ratos SHR (n = 16) e Wistar (n = 16) com 08 semanas de idade foram aleatoriamente divididos em 4 grupos: controle sedentário (CS, n = 8); controle treinado (CT, n = 8); SHR sedentário (HS, n = 8) e SHR treinado (HT, n = 8). O treinamento físico foi realizado em aparato com degraus (1,1 × 0,18 m, 2 cm entre os degraus, 80° inclinação) com peso fixado na cauda, (5 vezes por semana durante 8 semanas). O controle barorreflexo da frequência cardíaca (FC) foi testado com estímulos de fenilefrina e nitroprussiato de sódio. O treinamento resistido foi capaz de aumentar a massa muscular do sóleo em ratos SHR (HS 0,027 ± 0,002 g/mm e HT 0,056 ± 0,003 g/mm). Não houve alteração da PA com o treinamento. Por outro lado, houve melhora na resposta bradicárdica da sensibilidade barorreflexa no grupo HT (HS -1,3 ± 0,1 bpm/mmHg e HT -2,6 ± 0,2 bpm/mmHg), no entanto, a resposta taquicárdica não foi alterada pelo exercício resistido (CS -3,3 ± 0,2 bpm/mmHg, CT -3,3 ± 0,1 bpm/mmHg, HS -1,47 ± 0,06 e HT -1,6 ± 0,1). O exercício físico resistido foi capaz de otimizar a sensibilidade barorreflexa dos ratos SHR por meio da melhora à resposta bradicárdica, apesar de não alterar a PA.

  17. Heart Rate Responses to Autonomic Challenges in Obstructive Sleep Apnea

    PubMed Central

    Macey, Paul M.; Kumar, Rajesh; Woo, Mary A.; Yan-Go, Frisca L.; Harper, Ronald M.

    2013-01-01

    Obstructive sleep apnea (OSA) is accompanied by structural alterations and dysfunction in central autonomic regulatory regions, which may impair dynamic and static cardiovascular regulation, and contribute to other syndrome pathologies. Characterizing cardiovascular responses to autonomic challenges may provide insights into central nervous system impairments, including contributions by sex, since structural alterations are enhanced in OSA females over males. The objective was to assess heart rate responses in OSA versus healthy control subjects to autonomic challenges, and, separately, characterize female and male patterns. We studied 94 subjects, including 37 newly-diagnosed, untreated OSA patients (6 female, age mean±std: 52.1±8.1 years; 31 male aged 54.3±8.4 years), and 57 healthy control subjects (20 female, 50.5±8.1 years; 37 male, 45.6±9.2 years). We measured instantaneous heart rate with pulse oximetry during cold pressor, hand grip, and Valsalva maneuver challenges. All challenges elicited significant heart rate differences between OSA and control groups during and after challenges (repeated measures ANOVA, p<0.05). In post-hoc analyses, OSA females showed greater impairments than OSA males, which included: for cold pressor, lower initial increase (OSA vs. control: 9.5 vs. 7.3 bpm in females, 7.6 vs. 3.7 bpm in males), OSA delay to initial peak (2.5 s females/0.9 s males), slower mid-challenge rate-of-increase (OSA vs. control: −0.11 vs. 0.09 bpm/s in females, 0.03 vs. 0.06 bpm/s in males); for hand grip, lower initial peak (OSA vs. control: 2.6 vs. 4.6 bpm in females, 5.3 vs. 6.0 bpm in males); for Valsalva maneuver, lower Valsalva ratio (OSA vs. control: 1.14 vs. 1.30 in females, 1.29 vs. 1.34 in males), and OSA delay during phase II (0.68 s females/1.31 s males). Heart rate responses showed lower amplitude, delayed onset, and slower rate changes in OSA patients over healthy controls, and impairments may be more pronounced in females. The dysfunctions may reflect central injury in the syndrome, and suggest autonomic deficiencies that may contribute to further tissue and functional pathologies. PMID:24194842

  18. Coronary CT Angiography Incorporating Doppler-Guided Prospective ECG Gating in Patients with High Heart Rate: Comparison with Results of Traditional Prospective ECG Gating

    PubMed Central

    Li, Min; Yu, Bing-bing; Wu, Jian-hua; Xu, Lin; Sun, Gang

    2013-01-01

    Purpose As Doppler ultrasound has been proven to be an effective tool to predict and compress the optimal pulsing windows, we evaluated the effective dose and diagnostic accuracy of coronary CT angiography (CTA) incorporating Doppler-guided prospective electrocardiograph (ECG) gating, which presets pulsing windows according to Doppler analysis, in patients with a heart rate >65 bpm. Materials and Methods 119 patients with a heart rate >65 bpm who were scheduled for invasive coronary angiography were prospectively studied, and patients were randomly divided into traditional prospective (n = 61) and Doppler-guided prospective (n = 58) ECG gating groups. The exposure window of traditional prospective ECG gating was set at 30%–80% of the cardiac cycle. For the Doppler group, the length of diastasis was analyzed by Doppler. For lengths greater than 90 ms, the pulsing window was preset during diastole (during 60%–80%); otherwise, the optimal pulsing intervals were moved from diastole to systole (during 30%–50%). Results The mean heart rates of the traditional ECG and the Doppler-guided group during CT scanning were 75.0±7.7 bpm (range, 66–96 bpm) and 76.5±5.4 bpm (range: 66–105 bpm), respectively. The results indicated that whereas the image quality showed no significant difference between the traditional and Doppler groups (P = 0.42), the radiation dose of the Doppler group was significantly lower than that of the traditional group (5.2±3.4mSv vs. 9.3±4.5mSv, P<0.001). The sensitivities of CTA applying traditional and Doppler-guided prospective ECG gating to diagnose stenosis on a segment level were 95.5% and 94.3%, respectively; specificities 98.0% and 97.1%, respectively; positive predictive values 90.7% and 88.2%, respectively; negative predictive values 99.0% and 98.7%, respectively. There was no statistical difference in concordance between the traditional and Doppler groups (P = 0.22). Conclusion Doppler-guided prospective ECG gating represents an improved method in patients with a high heart rate to reduce effective radiation doses, while maintaining high diagnostic accuracy. PMID:23696793

  19. Changes in Heart Rate Associated with Exenatide Once Weekly: Pooled Analysis of Clinical Data in Patients with Type 2 Diabetes.

    PubMed

    Marso, Steven P; Hardy, Elise; Han, Jenny; Wang, Hui; Chilton, Robert J

    2018-04-01

    Glucagon-like peptide-1 receptor agonists (GLP-1RAs) improve glycemia in patients with type 2 diabetes, but heart rate increases have been observed. A pooled post hoc analysis of 11 randomized clinical trials (N = 4595) of 10-30 weeks' duration from the exenatide once-weekly (QW) development program evaluated heart rate with exenatide QW (intervention group) and exenatide twice daily (BID), liraglutide, and non-GLP-1RAs (insulin, metformin, pioglitazone, and sitagliptin) (comparison groups). The time course and size of heart rate changes from baseline and the relationship of heart rate change with baseline heart rate were studied. A multivariate analysis (9 studies; N = 3903) examined associations between patient characteristics or treatments and heart rate increases. Mean baseline heart rate ± standard deviation was 75.0 ± 8.5 beats per minute (bpm) with exenatide QW (n = 2096), 75.8 ± 8.7 bpm with exenatide BID (n = 606), 75.2 ± 8.9 bpm with liraglutide (n = 450), and 74.5 ± 8.6 bpm with non-GLP-1RAs (n = 1443). Least-squares mean ± standard error changes from baseline to final heart rate were + 2.7 ± 0.2, + 1.0 ± 0.3, and + 3.0 ± 0.4 bpm with exenatide QW, exenatide BID, and liraglutide, respectively, and - 0.8 ± 0.2 bpm with non-GLP-1RAs. The size and direction of heart rate changes in individual patients varied within each treatment group at all time points. At posttreatment follow-up, heart rate reverted to the baseline level after GLP-1RA discontinuation. Heart rate changes correlated negatively with baseline heart rate for all therapies (r = - 0.3 to - 0.4). Baseline heart rate was the strongest predictor of increased heart rate. Small increases in heart rate were associated with exenatide QW, exenatide BID, and liraglutide treatments but reverted to baseline after discontinuation. Increases were more likely in patients with a low baseline heart rate. The clinical relevance of these heart rate increases is unknown but will be clarified by several ongoing and recently completed cardiovascular outcome studies.

  20. Telescience - Concepts And Contributions To The Extreme Ultraviolet Explorer Mission

    NASA Astrophysics Data System (ADS)

    Marchant, Will; Dobson, Carl; Chakrabarti, Supriya; Malina, Roger F.

    1987-10-01

    A goal of the telescience concept is to allow scientists to use remotely located instruments as they would in their laboratory. Another goal is to increase reliability and scientific return of these instruments. In this paper we discuss the role of transparent software tools in development, integration, and postlaunch environments to achieve hands on access to the instrument. The use of transparent tools helps to reduce the parallel development of capability and to assure that valuable pre-launch experience is not lost in the operations phase. We also discuss the use of simulation as a rapid prototyping technique. Rapid prototyping provides a cost-effective means of using an iterative approach to instrument design. By allowing inexpensive produc-tion of testbeds, scientists can quickly tune the instrument to produce the desired scientific data. Using portions of the Extreme Ultraviolet Explorer (EUVE) system, we examine some of the results of preliminary tests in the use of simulation and tran-sparent tools. Additionally, we discuss our efforts to upgrade our software "EUVE electronics" simulator to emulate a full instrument, and give the pros and cons of the simulation facilities we have developed.

  1. Assembly Tests of the First Nb 3 Sn Low-Beta Quadrupole Short Model for the Hi-Lumi LHC

    DOE PAGES

    Pan, H.; Felice, H.; Cheng, D. W.; ...

    2016-01-18

    In preparation for the high-luminosity upgrade of the Large Hadron Collider (LHC), the LHC Accelerator Research Program (LARP) in collaboration with CERN is pursuing the development of MQXF: a 150-mm-aperture high-field Nb3Sn quadrupole magnet. Moreover, the development phase starts with the fabrication and test of several short models (1.2-m magnetic length) and will continue with the development of several long prototypes. All of them are mechanically supported using a shell-based support structure, which has been extensively demonstrated on several R&D models within LARP. The first short model MQXFS-AT has been assembled at LBNL with coils fabricated by LARP and CERN.more » In our paper, we summarize the assembly process and show how it relies strongly on experience acquired during the LARP 120-mm-aperture HQ magnet series. We also present comparison between strain gauges data and finite-element model analysis. Finally, we present the implication of the MQXFS-AT experience on the design of the long prototype support structure.« less

  2. First Performance Results of the PIP2IT MEBT 200 Ohm Kicker Prototype

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Saewert, G.; Awida, M. H.; Chase, B. E.

    The PIP-II project is a program to upgrade the Fermilab accelerator complex. The PIP-II linac includes a 2.1 MeV Medium Energy Beam Transport (MEBT) section that incorporates a unique chopping system to perform arbitrary, bunch-by-bunch removal of 162.5 MHz structured beam. The MEBT chopping system will consist of two identical kickers working together and a beam absorber. One design of two having been proposed has been a 200 Ohm characteristic impedance traveling wave dual-helix kicker driven with custom designed high-speed switches. This paper reports on the first performance results of one prototype kicker built, installed and tested with beam at the PIP-II Injector Test (PIP2IT) facility. The helix deflector design details are discussed. The electrical performance of the high-speed switch driver operating at 500 V bias is presented. Tests performed were chopping beam at 81.25 MHz for microseconds as well as with a truly arbitrary pattern for 550more » $$\\mu$$s bursts having a 45 MHz average switching rate and repeating at 20 Hz.« less

  3. NSLS-II BPM System Protection from Rogue Mode Coupling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blednykh, A.; Bach, B.; Borrelli, A.

    2011-03-28

    Rogue mode RF shielding has been successfully designed and implemented into the production multipole vacuum chambers. In order to avoid systematic errors in the NSLS-II BPM system we introduced frequency shift of HOM's by using RF metal shielding located in the antechamber slot of each multipole vacuum chamber. To satisfy the pumping requirement the face of the shielding has been perforated with roughly 50 percent transparency. It stays clear of synchrotron radiation in each chamber.

  4. 500 MHz narrowband beam position monitor electronics for electron synchrotrons

    NASA Astrophysics Data System (ADS)

    Mohos, I.; Dietrich, J.

    1998-12-01

    Narrowband beam position monitor electronics were developed in the Forschungszentrum Jülich-IKP for the orbit measurement equipment used at ELSA Bonn. The equipment uses 32 monitor chambers, each with four capacitive button electrodes. The monitor electronics, consisting of an rf signal processing module (BPM-RF) and a data acquisition and control module (BPM-DAQ), sequentially process and measure the monitor signals and deliver calculated horizontal and vertical beam position data via a serial network.

  5. Diagnosis and characterization of mania: Quantifying increased energy and activity in the human behavioral pattern monitor.

    PubMed

    Perry, William; McIlwain, Meghan; Kloezeman, Karen; Henry, Brook L; Minassian, Arpi

    2016-06-30

    Increased energy or activity is now an essential feature of the mania of Bipolar Disorder (BD) according to DSM-5. This study examined whether objective measures of increased energy can differentiate manic BD individuals and provide greater diagnostic accuracy compared to rating scales, extending the work of previous studies with smaller samples. We also tested the relationship between objective measures of energy and rating scales. 50 hospitalized manic BD patients were compared to healthy subjects (HCS, n=39) in the human Behavioral Pattern Monitor (hBPM) which quantifies motor activity and goal-directed behavior in an environment containing novel stimuli. Archival hBPM data from 17 schizophrenia patients were used in sensitivity and specificity analyses. Manic BD patients exhibited higher motor activity than HCS and higher novel object interactions. hBPM activity measures were not correlated with observer-rated symptoms, and hBPM activity was more sensitive in accurately classifying hospitalized BD subjects than observer ratings. Although the findings can only be generalized to inpatient populations, they suggest that increased energy, particularly specific and goal-directed exploration, is a distinguishing feature of BD mania and is best quantified by objective measures of motor activity. A better understanding is needed of the biological underpinnings of this cardinal feature. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  6. Interplay between Clinical Guidelines and Organizational Workflow Systems. Experience from the MobiGuide Project.

    PubMed

    Shabo, Amnon; Peleg, Mor; Parimbelli, Enea; Quaglini, Silvana; Napolitano, Carlo

    2016-12-07

    Implementing a decision-support system within a healthcare organization requires integration of clinical domain knowledge with resource constraints. Computer-interpretable guidelines (CIG) are excellent instruments for addressing clinical aspects while business process management (BPM) languages and Workflow (Wf) engines manage the logistic organizational constraints. Our objective is the orchestration of all the relevant factors needed for a successful execution of patient's care pathways, especially when spanning the continuum of care, from acute to community or home care. We considered three strategies for integrating CIGs with organizational workflows: extending the CIG or BPM languages and their engines, or creating an interplay between them. We used the interplay approach to implement a set of use cases arising from a CIG implementation in the domain of Atrial Fibrillation. To provide a more scalable and standards-based solution, we explored the use of Cross-Enterprise Document Workflow Integration Profile. We describe our proof-of-concept implementation of five use cases. We utilized the Personal Health Record of the MobiGuide project to implement a loosely-coupled approach between the Activiti BPM engine and the Picard CIG engine. Changes in the PHR were detected by polling. IHE profiles were used to develop workflow documents that orchestrate cross-enterprise execution of cardioversion. Interplay between CIG and BPM engines can support orchestration of care flows within organizational settings.

  7. Hydrogen Generation Through Renewable Energy Sources at the NASA Glenn Research Center

    NASA Technical Reports Server (NTRS)

    Colozza, Anthony; Prokopius, Kevin

    2007-01-01

    An evaluation of the potential for generating high pressure, high purity hydrogen at the NASA Glenn Research Center (GRC) was performed. This evaluation was based on producing hydrogen utilizing a prototype Hamilton Standard electrolyzer that is capable of producing hydrogen at 3000 psi. The present state of the electrolyzer system was determined to identify the refurbishment requirements. The power for operating the electrolyzer would be produced through renewable power sources. Both wind and solar were considered in the analysis. The solar power production capability was based on the existing solar array field located at NASA GRC. The refurbishment and upgrade potential of the array field was determined and the array output was analyzed with various levels of upgrades throughout the year. The total available monthly and yearly energy from the array was determined. A wind turbine was also sized for operation. This sizing evaluated the wind potential at the site and produced an operational design point for the wind turbine. Commercially available wind turbines were evaluated to determine their applicability to this site. The system installation and power integration were also addressed. This included items such as housing the electrolyzer, power management, water supply, gas storage, cooling and hydrogen dispensing.

  8. Ultrasonic Stir Welding Development for Ground-Based and In Situ Fabrication and Repair for In-Space Propulsion Systems/Commercial Space Sector

    NASA Technical Reports Server (NTRS)

    Ding, Jeff

    2015-01-01

    The completed Center Innovation Fund (CIF) project used the upgraded Ultrasonic Stir Weld (USW) Prototype System (built in 2013/2014) to begin characterizing the weld process using 2219 aluminum (fig. 1). This work is being done in Bldg. 4755 at NASA Marshall Space Flight Center (MSFC). The capabilities of the USW system provides the means to precisely control and document individual welding parameters. The current upgraded system has the following capabilities: (1) Ability to 'pulse' ultrasonic (US) energy on and off and adjust parameters real-time (travel speed, spindle rpm, US amplitude, X and Z axis positions, and plunge and pin axis force; (2) Means to measure draw force; (3) Ability to record US power versus time; (4) Increasing stiffness of Z axis drive and reduce head deflection using laser technology; (5) Adding linear encoder to better control tool penetration setting; (6) Ultrasonic energy integrated into stir rod and containment plate; (7) Maximum 600 rpm; (8) Maximum Z force 15,000 lb; (9) Real-time data acquisition and logging capabilities at a minimum frequency of 10 Hz; and (10) Two separate transducer power supplies operating at 4.5 kW power.

  9. L1 track trigger for the CMS HL-LHC upgrade using AM chips and FPGAs

    NASA Astrophysics Data System (ADS)

    Fedi, Giacomo

    2017-08-01

    The increase of luminosity at the HL-LHC will require the introduction of tracker information in CMS's Level-1 trigger system to maintain an acceptable trigger rate when selecting interesting events, despite the order of magnitude increase in minimum bias interactions. To meet the latency requirements, dedicated hardware has to be used. This paper presents the results of tests of a prototype system (pattern recognition ezzanine) as core of pattern recognition and track fitting for the CMS experiment, combining the power of both associative memory custom ASICs and modern Field Programmable Gate Array (FPGA) devices. The mezzanine uses the latest available associative memory devices (AM06) and the most modern Xilinx Ultrascale FPGAs. The results of the test for a complete tower comprising about 0.5 million patterns is presented, using as simulated input events traversing the upgraded CMS detector. The paper shows the performance of the pattern matching, track finding and track fitting, along with the latency and processing time needed. The pT resolution over pT of the muons measured using the reconstruction algorithm is at the order of 1% in the range 3-100 GeV/c.

  10. CMOS cassette for digital upgrade of film-based mammography systems

    NASA Astrophysics Data System (ADS)

    Baysal, Mehmet A.; Toker, Emre

    2006-03-01

    While full-field digital mammography (FFDM) technology is gaining clinical acceptance, the overwhelming majority (96%) of the installed base of mammography systems are conventional film-screen (FSM) systems. A high performance, and economical digital cassette based product to conveniently upgrade FSM systems to FFDM would accelerate the adoption of FFDM, and make the clinical and technical advantages of FFDM available to a larger population of women. The planned FFDM cassette is based on our commercial Digital Radiography (DR) cassette for 10 cm x 10 cm field-of-view spot imaging and specimen radiography, utilizing a 150 micron columnar CsI(Tl) scintillator and 48 micron active-pixel CMOS sensor modules. Unlike a Computer Radiography (CR) cassette, which requires an external digitizer, our DR cassette transfers acquired images to a display workstation within approximately 5 seconds of exposure, greatly enhancing patient flow. We will present the physical performance of our prototype system against other FFDM systems in clinical use today, using established objective criteria such as the Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE), and subjective criteria, such as a contrast-detail (CD-MAM) observer performance study. Driven by the strong demand from the computer industry, CMOS technology is one of the lowest cost, and the most readily accessible technologies available for FFDM today. Recent popular use of CMOS imagers in high-end consumer cameras have also resulted in significant advances in the imaging performance of CMOS sensors against rivaling CCD sensors. This study promises to take advantage of these unique features to develop the first CMOS based FFDM upgrade cassette.

  11. Volumetric Single-Beat Coronary Computed Tomography Angiography: Relationship of Image Quality, Heart Rate, and Body Mass Index. Initial Patient Experience With a New Computed Tomography Scanner.

    PubMed

    Latif, Muhammad Aamir; Sanchez, Frank W; Sayegh, Karl; Veledar, Emir; Aziz, Muhammad; Malik, Rehan; Haider, Imran; Agatston, Arthur S; Batlle, Juan C; Janowitz, Warren; Peña, Constantino; Ziffer, Jack A; Nasir, Khurram; Cury, Ricardo C

    2016-01-01

    Cardiac computed tomography (CT) image quality (IQ) is very important for accurate diagnosis. We propose to evaluate IQ expressed as Likert scale, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) from coronary CT angiography images acquired with a new volumetric single-beat CT scanner on consecutive patients and assess the IQ dependence on heart rate (HR) and body mass index (BMI). We retrospectively analyzed the data of the first 439 consecutive patients (mean age, 55.13 [SD, 12.1] years; 51.47% male), who underwent noninvasive coronary CT angiography in a new single-beat volumetric CT scanner (Revolution CT) to evaluate chest pain at West Kendall Baptist Hospital. Based on patient BMI (mean, 29.43 [SD, 5.81] kg/m), the kVp (kilovolt potential) value and tube current were adjusted within a range of 80 to 140 kVp and 122 to 720 mA, respectively. Each scan was performed in a single-beat acquisition within 1 cardiac cycle, regardless of the HR. Motion correction software (SnapShot Freeze) was used for correcting motion artifacts in patients with higher HRs. Autogating was used to automatically acquire systolic and diastolic phases for higher HRs with electrocardiographic milliampere dose modulation. Image quality was assessed qualitatively by Likert scale and quantitatively by SNR and CNR for the 4 major vessels right coronary, left main, left anterior descending, and left circumflex arteries on axial and multiplanar reformatted images. Values for Likert scale were as follows: 1, nondiagnostic; 2, poor; 3, good; 4, very good; and 5, excellent. Signal-to-noise ratio and CNR were calculated from the average 2 CT attenuation values within regions of interest placed in the proximal left main and proximal right coronary artery. For contrast comparison, a region of interest was selected from left ventricular wall at midcavity level using a dedicated workstation. We divided patients in 2 groups related to the HR: less than or equal to 70 beats/min (bpm) and greater than 70 bpm and also analyzed them in 2 BMI groupings: BMI less than or equal to 30 kg/m and BMI greater than 30 kg/m. Mean SNR was 8.7 (SD, 3.1) (n = 349) for group with HR 70 bpm or less and 7.7 (SD, 2.4) (n = 78) for group with HR greater than 70 bpm (P = 0.008). Mean CNR was 6.9 (SD, 2.7) (n = 349) for group with HR 70 bpm or less and 5.9 (SD, 2.2) (n = 78) for group with HR 70 bpm or greater (P = 0.002). Mean SNR was 8.8 (SD, 3.2) (n = 249) for group with BMI 30 kg/m or less and 8.1 (SD, 2.6) (n = 176) for group with BMI greater than 30 kg/m (P = 0.008). Mean CNR was 7.0 (SD, 2.8) (n = 249) for group with BMI 30 kg/m or less and 6.4 (SD, 2.4) (n = 176) for group with BMI greater than 30 kg/m (P = 0.002). The results for mean Likert scale values were statistically different, reflecting difference in IQ between people with HR 70 bpm or less and greater than 70 bpm, BMI 30 kg/m or less, and BMI greater than 30 kg/m.

  12. [Status of β-blocker use and heart rate control in Chinese patients with stable coronary artery disease].

    PubMed

    Sun, Yihong; Yu, Jinming; Hu, Dayi

    2016-01-01

    To observe the current status of β-blocker (BB) use and heart rate control in Chinese patients with stable coronary artery disease (SCAD) based on subgroup data of the prospective observational longitudinal registry of patients with stable coronary artery disease (CLARIFY). The CLARIFY study is an international prospective observational registry of outpatients with SCAD. From November 2009 to July 2010, patients with SCAD were enrolled, and demographic information, clinical indicators, medication and blood flow reconstruction were collected. Patients were divided in three mutually exclusive categories by baseline pulse palpation heart rate(HR)≤60 beats per minute (bpm)(n=397), 61-69 bpm(n=782), and ≥70 bpm(n=1 443). The patients were also divided into taking BB or not taking BB groups. The aim of present study is to describe and analyze the current status and factors related to the HR control and BB use in the Chinese subgroup of CLARIFY. A total of 2 622 patients were enrolled from 56 centers across China. The mean age was (63.6±10.3) years old with 75.6% (1 983) male patients, 55.0% (1 443) patients had HR≥70 bpm. Mean HR measure by electrocardiogram(ECG) was (69.4±10.2)bpm, 50.9% (1 334 cases) patients had myocardial infarction(MI) history. A total of 21.9%(575 cases) patients had anginal symptoms; coronary angiography was performed in 88.8%(2 327 cases) of the patients. 76.2%(1 997 cases) patients were treated with BB (any molecule and any dose), 2.7% (70 cases) with digoxin or derivatives, 3.9% (103 cases) with verapamil or diltiazem, and 1.8% (47 cases) with amiodarone or dronedarone and 0.1%(2 cases) received ivabradine. BB use was similar among 3 HR groups(P>0.05). The independent risk factors associated with HR≥70 bpm were diabetes(OR=1.31), current smoker(OR=1.57), chronic heart failure(CHF) with NYHA Ⅲ (OR=2.13) and increased diastolic blood pressure (OR=1.30). Conversely, high physical activity (OR=0.61), former smoker (OR=0.76) and history of percutaneous coronary intervention(PCI, OR=0.80) were associated with lower risk of HR≥70 bpm (all P<0.05). The independent risk factors associated with non-BB use were older age (OR=1.11, 95%CI 1.01-1.47, P=0.005), lower diastolic blood pressure (OR=1.47, 95%CI 1.32-1.68, P=0.012), no history of MI (OR=1.86, 95%CI 1.43-2.44, P<0.001) or PCI (OR=1.94, 95%CI 1.55-3.73, P<0.001), asthma/chronic obstructive pulmonary disease (OR=1.32, 95%CI 1.15-1.99, P<0.001). A total of 76.2% Chinese SCAD patients received BB medication but more than half of them did not reach the optimal HR. Clinical characteristics including diabetes, current smoker, CHF, increased diastolic blood pressure and no PCI were associated with poorly controlled HR(≥70 bpm). More efforts including adjusting the type and dose of heart rate lowering drugs are needed to achieve optimal HR control in Chinese SCAD patients. Clinical Trail Registry International Standard Randomized Controlled Trial, ISRCTN43070564.

  13. Effect of Metoprolol Succinate in Patients with Stable Angina and Elevated Heart Rate Receiving Low-Dose β-Blocker Therapy.

    PubMed

    Jiang, Jie; Cong, Hongliang; Zhang, Yan; Li, Zhanquan; Tao, Guizhou; Li, Xiaodong; Qing, Liang; Tan, Ning; Zhao, Zhichen; Dong, Yugang; Ji, Zheng; Chen, Yundai; Ge, Junbo; He, Ben; Sun, Yingxian; Cao, Kejiang; Huo, Yong

    2017-01-01

    Aims: β-blockers are underused in Chinese patients with coronary heart disease. The prescribed dose is often low. The aim of this study was to investigate the effect of metoprolol succinate doses of 95 mg and 190 mg on heart rate (HR) control, as well as drug tolerance, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Methods: This was a multicenter, randomized, open-label, parallel-group trial in 15 clinical sites. Patients with stable angina, taking low-dose β-blockers (equivalent to metoprolol succinate 23.75-47.5 mg/day), and having a resting HR of ≥ 65 bpm were enrolled and randomized to either the metoprolol 95-mg group or the 190-mg group. The change in 24-h average HR from baseline recorded by Holter monitoring and the percentages of patients with resting HR controlled to ≤ 60 bpm were compared between the two groups. Results: Two hundred thirty-one patients entered the intent-to-treat population for the main analysis. The change in 24-h average HR from baseline was -0.62 ± 0.66 bpm in the 95 mg group and -2.99 ± 0.62 bpm in the 190 mg group (p = 0.0077) after 8 weeks of treatment. The percentages of patients with resting HR controlled to ≤ 60 bpm were 24.1% (95% CI: 16.35%, 31.93%) and 40.0% (95% CI: 31.05%, 48.95%), respectively (p = 0.0019). Only 4 and 2 of the patients, respectively, discontinued the study drugs because of hypotension or bradycardia. Conclusions: The metoprolol succinate dose of 190 mg is superior to the 95 mg dose in terms of HR control, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Both doses were well tolerated.

  14. The cost effectiveness of ivabradine in the treatment of chronic heart failure from the U.K. National Health Service perspective.

    PubMed

    Griffiths, A; Paracha, N; Davies, A; Branscombe, N; Cowie, M R; Sculpher, M

    2014-07-01

    Ivabradine, a specific heart rate lowering therapy, has been shown in a randomised placebo-controlled study, Systolic HF Treatment with the If Inhibitor Ivabradine Trial (SHIfT), to significantly reduce the composite end point of cardiovascular death and hospitalisation for worsening heart failure (HF) in patients with systolic HF who are in sinus rhythm and with a heart rate ≥70 bpm, when added to optimised medical therapy (HR: 0.82, 95% CI 0.75 to 0.90, p<0.0001). We assessed the cost effectiveness of ivabradine, from a UK National Health Service perspective, based on the results of SHIfT. A Markov model estimated the cost effectiveness of ivabradine compared with standard care for two cohorts of patients with HF (heart rate ≥75 bpm in line with the EU labelled indication; and heart rate ≥70 bpm in line with the SHIfT study population). Modelled outcomes included death, hospitalisation, quality of life and New York Heart Association class. Total costs and quality adjusted life years (QALYs) for ivabradine and standard care were estimated over a lifetime horizon. The incremental cost per additional QALY for ivabradine plus standard care versus standard care has been estimated as £8498 for heart rate ≥75 bpm and £13 764 for heart rate ≥70 bpm. Ivabradine is expected to have a 95% chance of being cost-effective in the EU licensed population using the current National Institute for Health and Care Excellence cost effectiveness threshold of £20 000 per QALY. These results were robust in sensitivity analyses. This economic evaluation suggests that the use of ivabradine is likely to be cost-effective in eligible patients with HF from a UK National Health Service perspective. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

  15. Sympathetic activation in exercise is not dependent on muscle acidosis. Direct evidence from studies in metabolic myopathies

    NASA Technical Reports Server (NTRS)

    Vissing, J.; Vissing, S. F.; MacLean, D. A.; Saltin, B.; Quistorff, B.; Haller, R. G.; Blomqvist, C. G. (Principal Investigator)

    1998-01-01

    Muscle acidosis has been implicated as a major determinant of reflex sympathetic activation during exercise. To test this hypothesis we studied sympathetic exercise responses in metabolic myopathies in which muscle acidosis is impaired or augmented during exercise. As an index of reflex sympathetic activation to muscle, microneurographic measurements of muscle sympathetic nerve activity (MSNA) were obtained from the peroneal nerve. MSNA was measured during static handgrip exercise at 30% of maximal voluntary contraction force to exhaustion in patients in whom exercise-induced muscle acidosis is absent (seven myophosphorylase deficient patients; MD [McArdle's disease], and one patient with muscle phosphofructokinase deficiency [PFKD]), augmented (one patient with mitochondrial myopathy [MM]), or normal (five healthy controls). Muscle pH was monitored by 31P-magnetic resonance spectroscopy during handgrip exercise in the five control subjects, four MD patients, and the MM and PFKD patients. With handgrip to exhaustion, the increase in MSNA over baseline (bursts per minute [bpm] and total activity [%]) was not impaired in patients with MD (17+/-2 bpm, 124+/-42%) or PFKD (65 bpm, 307%), and was not enhanced in the MM patient (24 bpm, 131%) compared with controls (17+/-4 bpm, 115+/-17%). Post-handgrip ischemia studied in one McArdle patient, caused sustained elevation of MSNA above basal suggesting a chemoreflex activation of MSNA. Handgrip exercise elicited an enhanced drop in muscle pH of 0.51 U in the MM patient compared with the decrease in controls of 0.13+/-0.02 U. In contrast, muscle pH increased with exercise in MD by 0.12+/-0.05 U and in PFKD by 0.01 U. In conclusion, patients with glycogenolytic, glycolytic, and oxidative phosphorylation defects show normal muscle sympathetic nerve responses to static exercise. These findings indicate that muscle acidosis is not a prerequisite for sympathetic activation in exercise.

  16. Brain-computer interfaces using capacitive measurement of visual or auditory steady-state responses

    NASA Astrophysics Data System (ADS)

    Baek, Hyun Jae; Kim, Hyun Seok; Heo, Jeong; Lim, Yong Gyu; Park, Kwang Suk

    2013-04-01

    Objective. Brain-computer interface (BCI) technologies have been intensely studied to provide alternative communication tools entirely independent of neuromuscular activities. Current BCI technologies use electroencephalogram (EEG) acquisition methods that require unpleasant gel injections, impractical preparations and clean-up procedures. The next generation of BCI technologies requires practical, user-friendly, nonintrusive EEG platforms in order to facilitate the application of laboratory work in real-world settings. Approach. A capacitive electrode that does not require an electrolytic gel or direct electrode-scalp contact is a potential alternative to the conventional wet electrode in future BCI systems. We have proposed a new capacitive EEG electrode that contains a conductive polymer-sensing surface, which enhances electrode performance. This paper presents results from five subjects who exhibited visual or auditory steady-state responses according to BCI using these new capacitive electrodes. The steady-state visual evoked potential (SSVEP) spelling system and the auditory steady-state response (ASSR) binary decision system were employed. Main results. Offline tests demonstrated BCI performance high enough to be used in a BCI system (accuracy: 95.2%, ITR: 19.91 bpm for SSVEP BCI (6 s), accuracy: 82.6%, ITR: 1.48 bpm for ASSR BCI (14 s)) with the analysis time being slightly longer than that when wet electrodes were employed with the same BCI system (accuracy: 91.2%, ITR: 25.79 bpm for SSVEP BCI (4 s), accuracy: 81.3%, ITR: 1.57 bpm for ASSR BCI (12 s)). Subjects performed online BCI under the SSVEP paradigm in copy spelling mode and under the ASSR paradigm in selective attention mode with a mean information transfer rate (ITR) of 17.78 ± 2.08 and 0.7 ± 0.24 bpm, respectively. Significance. The results of these experiments demonstrate the feasibility of using our capacitive EEG electrode in BCI systems. This capacitive electrode may become a flexible and non-intrusive tool fit for various applications in the next generation of BCI technologies.

  17. A protocol to study ex vivo mouse working heart at human-like heart rate.

    PubMed

    Feng, Han-Zhong; Jin, Jian-Ping

    2018-01-01

    Genetically modified mice are widely used as experimental models to study human heart function and diseases. However, the fast rate of normal mouse heart at 400-600bpm limits its capacity of assessing kinetic parameters that are important for the physiology and pathophysiology of human heart that beats at a much slower rate (75-180bpm). To extend the value of mouse models, we established a protocol to study ex vivo mouse working hearts at a human-like heart rate. In the presence of 300μM lidocaine to lower pacemaker and conductive activities and prevent arrhythmia, a stable rate of 120-130bpm at 37°C is achieved for ex vivo mouse working hearts. The negative effects of decreased heart rate on force-frequency dependence and lidocaine as a myocardial depressant on intracellular calcium can be compensated by using a higher but still physiological level of calcium (2.75mM) in the perfusion media. Multiple parameters were studied to compare the function at the human-like heart rate with that of ex vivo mouse working hearts at the standard rate of 480bpm. The results showed that the conditions for slower heart rate in the presence of 300μM lidocaine did not have depressing effect on left ventricular pressure development, systolic and diastolic velocities and stroke volume with maintained positive inotropic and lusitropic responses to β-adrenergic stimulation. Compared with that at 480bpm, the human-like heart rate increased ventricular filling and end diastolic volume with enhanced Frank-Starling responses. Coronary perfusion was increased from longer relaxation time and interval between beats whereas cardiac efficiency was significantly improved. Although the intrinsic differences between mouse and human heart remain, this methodology for ex vivo mouse hearts to work at human-like heart rate extends the value of using genetically modified mouse models to study cardiac function and human heart diseases. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Improved Heart Rate Recovery After Marked Weight Loss Induced by Gastric Bypass Surgery: 2 Year Follow Up in the Utah Obesity Study

    PubMed Central

    Wasmund, Stephen L.; Yanowitz, Frank G.; Adams, Ted D.; Hunt, Steven C.; Hamdan, Mohamed H.; Litwin, Sheldon E.

    2010-01-01

    Background Obesity is associated with significantly increased cardiovascular mortality that has been attributed, in part, to sympathetic activation. Gastric bypass surgery (GBS) appears to increase long-term survival in the severely obese, but mechanisms responsible for this increase are still being sought. Heart rate (HR) recovery after exercise reflects the balance of cardiac autonomic input from the sympathetic and parasympathetic systems. Blunted HR recovery is a very powerful predictor of increased mortality while enhanced HR recovery portends a good prognosis. Objectives To evaluate the effect of marked weight loss achieved via GBS on HR recovery. Methods Severely obese patients underwent submaximal exercise testing (80% predicted maximum HR) at baseline and 2 years after GBS (n=153) or nonsurgical treatment (n=188). Results Patients in the GBS group lost an average of 100±37 lbs compared to 3±22 lbs in the nonsurgical group (p<0.001, GBS vs. nonsurgical). Resting HR decreased from 73 beats/minute (bpm) to 60 bpm in the GBS group and from 74 bpm to 68 bpm in nonsurgical patients (p<0.001). Heart rate recovery improved by 13 bpm in the GBS group and did not change in the nonsurgical group (p<0.001 GBS vs. nonsurgical). In multivariable analysis, the independent correlates of HR recovery at the 2-year time point were resting HR, treadmill time, age, body mass index and HOMA-IR. Conclusion Marked weight loss 2 years after GBS resulted in a significant decrease in resting HR and an enhancement in HR recovery after exercise. These changes are likely attributable to improvement in insulin sensitivity and cardiac autonomic balance. Whether and to what extent this contributes to a reduction in cardiovascular mortality with GBS remains to be determined. PMID:20970524

  19. Effect of Metoprolol Succinate in Patients with Stable Angina and Elevated Heart Rate Receiving Low-Dose β-Blocker Therapy

    PubMed Central

    Jiang, Jie; Cong, Hongliang; Zhang, Yan; Li, Zhanquan; Tao, Guizhou; Li, Xiaodong; Qing, Liang; Tan, Ning; Zhao, Zhichen; Dong, Yugang; Ji, Zheng; Chen, Yundai; Ge, Junbo; He, Ben; Sun, Yingxian; Cao, Kejiang; Huo, Yong

    2017-01-01

    Aims: β-blockers are underused in Chinese patients with coronary heart disease. The prescribed dose is often low. The aim of this study was to investigate the effect of metoprolol succinate doses of 95 mg and 190 mg on heart rate (HR) control, as well as drug tolerance, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Methods: This was a multicenter, randomized, open-label, parallel-group trial in 15 clinical sites. Patients with stable angina, taking low-dose β-blockers (equivalent to metoprolol succinate 23.75-47.5 mg/day), and having a resting HR of ≥ 65 bpm were enrolled and randomized to either the metoprolol 95-mg group or the 190-mg group. The change in 24-h average HR from baseline recorded by Holter monitoring and the percentages of patients with resting HR controlled to ≤ 60 bpm were compared between the two groups. Results: Two hundred thirty-one patients entered the intent-to-treat population for the main analysis. The change in 24-h average HR from baseline was -0.62 ± 0.66 bpm in the 95 mg group and -2.99 ± 0.62 bpm in the 190 mg group (p = 0.0077) after 8 weeks of treatment. The percentages of patients with resting HR controlled to ≤ 60 bpm were 24.1% (95% CI: 16.35%, 31.93%) and 40.0% (95% CI: 31.05%, 48.95%), respectively (p = 0.0019). Only 4 and 2 of the patients, respectively, discontinued the study drugs because of hypotension or bradycardia. Conclusions: The metoprolol succinate dose of 190 mg is superior to the 95 mg dose in terms of HR control, in Chinese patients with stable angina, low-dose β-blocker use and unsatisfactory HR control. Both doses were well tolerated. PMID:28539824

  20. Training symmetry of weight distribution after stroke: a randomized controlled pilot study comparing task-related reach, Bobath and feedback training approaches.

    PubMed

    Mudie, M H; Winzeler-Mercay, U; Radwan, S; Lee, L

    2002-09-01

    To determine (1) the most effective of three treatment approaches to retrain seated weight distribution long-term after stroke and (2) whether improvements could be generalized to weight distribution in standing. Inpatient rehabilitation unit. Forty asymmetrical acute stroke subjects were randomly allocated to one of four groups in this pilot study. Changes in weight distribution were compared between the 10 subjects of each of three treatment groups (task-specific reach, Bobath, or Balance Performance Monitor [BPM] feedback training) and a no specific treatment control group. One week of measurement only was followed by two weeks of daily training sessions with the treatment to which the subject was randomly allocated. Measurements were performed using the BPM daily before treatment sessions, two weeks after cessation of treatment and 12 weeks post study. Weight distribution was calculated in terms of mean balance (percentage of total body weight) or the mean of 300 balance points over a 30-s data run. In the short term, the Bobath approach was the most effective treatment for retraining sitting symmetry after stroke (p = 0.004). Training with the BPM and no training were also significant (p = 0.038 and p = 0.035 respectively) and task-specific reach training failed to reach significance (p = 0.26). At 12 weeks post study 83% of the BPM training group, 38% of the task-specific reach group, 29% of the Bobath group and 0% of the untrained group were found to be distributing their weight to both sides. Some generalization of symmetry training in sitting to standing was noted in the BPM training group which appeared to persist long term. Results should be treated with caution due to the small group sizes. However, these preliminary findings suggest that it might be possible to restore postural symmetry in sitting in the early stages of rehabilitation with therapy that focuses on creating an awareness of body position.

  1. Heart rate and ischemic stroke: the REasons for Geographic And Racial Differences in Stroke (REGARDS) study.

    PubMed

    O'Neal, Wesley T; Qureshi, Waqas T; Judd, Suzanne E; Meschia, James F; Howard, Virginia J; Howard, George; Soliman, Elsayed Z

    2015-12-01

    The association between resting heart rate and ischemic stroke remains unclear. To examine the association between resting heart rate and ischemic stroke. A total of 24 730 participants (mean age: 64 ± 9·3 years; 59% women; 41% blacks) from the REasons for Geographic And Racial Differences in Stroke (REGARDS) study who were free of stroke at the time of enrollment (2003-2007) were included in this analysis. Resting heart rate was determined from baseline electrocardiogram data. Heart rate was examined as a continuous variable per 10 bpm increase and also as a categorical variable using tertiles ( <61 bpm, 61 to 70 bpm, and >70 bpm). First-time ischemic stroke events were identified during follow-up and adjudicated by physician review. Over a median follow-up of 7·6 years, a total of 646 ischemic strokes occurred. In a Cox regression model adjusted for socio-demographics, cardiovascular risk factors, and potential confounders, each 10 bpm increase in heart rate was associated with a 10% increase in the risk of ischemic stroke (hazard ratio = 1·10, 95% confidence interval = 1·02, 1·18). In the categorical model, an increased risk of ischemic stroke was observed for heart rates in the middle (hazard ratio = 1·29, 95% confidence interval = 1·06, 1·57) and upper (hazard ratio = 1·37, 95% confidence interval = 1·12, 1·67) tertiles compared with the lower tertile. The results were consistent when the analysis was stratified by age, gender, race, exercise habits, hypertension, and coronary heart disease. In REGARDS, high resting heart rates were associated with an increased risk of ischemic stroke compared with low heart rates. Further research is needed to examine whether interventions aimed to reduce heart rate decrease stroke risk. © 2015 World Stroke Organization.

  2. Results of neutron irradiation of GEM detector for plasma radiation detection

    NASA Astrophysics Data System (ADS)

    Jednorog, S.; Bienkowska, B.; Chernyshova, M.; Łaszynska, E.; Prokopowicz, R.; Ziołkowski, A.

    2015-09-01

    The detecting devices dedicated for plasma monitoring will be exposed for massive fluxes of neutron, photons as well as other rays that are components of fusion reactions and their product interactions with plasma itself or surroundings. In result detecting module metallic components will be activated becoming a source of radiation. Moreover, electronics components could change their electronic properties. The prototype GEM detector constructed for monitoring soft X-ray radiation in ITER oriented tokamaks was used for plasma monitoring during experimental campaign on tokamak ASDEX Upgrade. After that it became a source of gamma radiation caused by neutrons. The present work contains description of detector activation in the laboratory conditions.

  3. Optimizing Floating Guard Ring Designs for FASPAX N-in-P Silicon Sensors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shin, Kyung-Wook; Bradford, Robert; Lipton, Ronald

    2016-10-06

    FASPAX (Fermi-Argonne Semiconducting Pixel Array X-ray detector) is being developed as a fast integrating area detector with wide dynamic range for time resolved applications at the upgraded Advanced Photon Source (APS.) A burst mode detector with intendedmore » $$\\mbox{13 $$MHz$}$ image rate, FASPAX will also incorporate a novel integration circuit to achieve wide dynamic range, from single photon sensitivity to $$10^{\\text{5}}$$ x-rays/pixel/pulse. To achieve these ambitious goals, a novel silicon sensor design is required. This paper will detail early design of the FASPAX sensor. Results from TCAD optimization studies, and characterization of prototype sensors will be presented.« less

  4. Building a Laboratory-Scale Biogas Plant and Verifying its Functionality

    NASA Astrophysics Data System (ADS)

    Boleman, Tomáš; Fiala, Jozef; Blinová, Lenka; Gerulová, Kristína

    2011-01-01

    The paper deals with the process of building a laboratory-scale biogas plant and verifying its functionality. The laboratory-scale prototype was constructed in the Department of Safety and Environmental Engineering at the Faculty of Materials Science and Technology in Trnava, of the Slovak University of Technology. The Department has already built a solar laboratory to promote and utilise solar energy, and designed SETUR hydro engine. The laboratory is the next step in the Department's activities in the field of renewable energy sources and biomass. The Department is also involved in the European Union project, where the goal is to upgrade all existed renewable energy sources used in the Department.

  5. Automotive Stirling Engine Development Program Mod I Stirling engine development

    NASA Technical Reports Server (NTRS)

    Simetkosky, M. A.

    1983-01-01

    The development of the Mod I 4-cylinder automotive Stirling engine is discussed and illustrated with drawings, block diagrams, photographs, and graphs and tables of preliminary test data. The engine and its drive, cold-engine, hot-engine, external-heat, air/fuel, power-control, electronic-control, and auxiliary systems are characterized. Performance results from a total of 1900 h of tests on 4 prototype engines include average maximum efficiency (at 2000 rpm) 34.5 percent and maximum output power 54.4 kW. The modifications introduced in an upgraded version of the Mod I are explained; this engine has maximum efficiency 40.4 percent and maximum power output 69.2 kW.

  6. Nanowires from dirty multi-crystalline Si for hydrogen generation

    NASA Astrophysics Data System (ADS)

    Li, Xiaopeng; Schweizer, Stefan L.; Sprafke, Alexander; Wehrspohn, Ralf B.

    2013-09-01

    Silicon nanowires are considered as a promising architecture for solar energy conversion systems. By metal assisted chemical etching of multi-crystalline upgraded metallurgical silicon (UMG-Si), large areas of silicon nanowires (SiNWs) with high quality can be produced on the mother substrates. These areas show a low reflectance comparable to black silicon. More interestingly, we find that various metal impurities inside UMG-Si are removed due to the etching through element analysis. A prototype cell was built to test the photoelectrochemical (PEC) properties of UMG-SiNWs for water splitting. The on-set potential for hydrogen evolution was much reduced, and the photocurrent density showed an increment of 35% in comparison with a `dirty' UMG-Si wafer.

  7. Front end optimization for the monolithic active pixel sensor of the ALICE Inner Tracking System upgrade

    NASA Astrophysics Data System (ADS)

    Kim, D.; Aglieri Rinella, G.; Cavicchioli, C.; Chanlek, N.; Collu, A.; Degerli, Y.; Dorokhov, A.; Flouzat, C.; Gajanana, D.; Gao, C.; Guilloux, F.; Hillemanns, H.; Hristozkov, S.; Junique, A.; Keil, M.; Kofarago, M.; Kugathasan, T.; Kwon, Y.; Lattuca, A.; Mager, M.; Sielewicz, K. M.; Marin Tobon, C. A.; Marras, D.; Martinengo, P.; Mazza, G.; Mugnier, H.; Musa, L.; Pham, T. H.; Puggioni, C.; Reidt, F.; Riedler, P.; Rousset, J.; Siddhanta, S.; Snoeys, W.; Song, M.; Usai, G.; Van Hoorne, J. W.; Yang, P.

    2016-02-01

    ALICE plans to replace its Inner Tracking System during the second long shut down of the LHC in 2019 with a new 10 m2 tracker constructed entirely with monolithic active pixel sensors. The TowerJazz 180 nm CMOS imaging Sensor process has been selected to produce the sensor as it offers a deep pwell allowing full CMOS in-pixel circuitry and different starting materials. First full-scale prototypes have been fabricated and tested. Radiation tolerance has also been verified. In this paper the development of the charge sensitive front end and in particular its optimization for uniformity of charge threshold and time response will be presented.

  8. Optical communication system performance with tracking error induced signal fading.

    NASA Technical Reports Server (NTRS)

    Tycz, M.; Fitzmaurice, M. W.; Premo, D. A.

    1973-01-01

    System performance is determined for an optical communication system using noncoherent detection in the presence of tracking error induced signal fading assuming (1) binary on-off modulation (OOK) with both fixed and adaptive threshold receivers, and (2) binary polarization modulation (BPM). BPM is shown to maintain its inherent 2- to 3-dB advantage over OOK when adaptive thresholding is used, and to have a substantially greater advantage when the OOK system is restricted to a fixed decision threshold.

  9. Comparison of RF BPM Receivers for NSLS-II Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pinayev,I.; Singh, O.

    2009-05-04

    The NSLS-II Light Source being built at Brookhaven National Laboratory requires submicron stability of the electron orbit in the storage ring in order to utilize fully very small emittances and electron beam sizes. This sets high stability requirements for beam position monitors and a program has been initiated for the purpose of characterizing RF beam position monitor (BPM) receivers in use at other light sources. Present state-of-the-art performance will be contrasted with more recently available technologies.

  10. ED01-0230-1

    NASA Image and Video Library

    2001-08-13

    NASA's Helios Prototype aircraft taking off from the Pacific Missile Range Facility, Kauai, Hawaii, for the record flight. As a follow-on to the Centurion (and earlier Pathfinder and Pathfinder-Plus) aircraft, the solar-powered Helios Prototype is the latest and largest example of a slow-flying ultralight flying wing designed for long-duration, high-altitude Earth science or telecommunications relay missions in the stratosphere. Developed by AeroVironment, Inc., of Monrovia, California, under NASA's Environmental Research Aircraft and Sensor Technology (ERAST) project, the unique craft is intended to demonstrate two key missions: the ability to reach and sustain horizontal flight at 100,000 feet altitude on a single-day flight in 2001, and to maintain flight above 50,000 feet altitude for at least four days in 2003, with the aid of a regenerative fuel cell-based energy storage system now in development. Both of these missions will be powered by electricity derived from non-polluting solar energy. The Helios Prototype is an enlarged version of the Centurion flying wing, which flew a series of test flights at NASA's Dryden Flight Research Center in late 1998. The craft has a wingspan of 247 feet, 41 feet greater than the Centurion, 2 1/2 times that of its solar-powered Pathfinder flying wing, and longer than the wingspans of either the Boeing 747 jetliner or Lockheed C-5 transport aircraft. The remotely piloted, electrically powered Helios Prototype went aloft on its maiden low-altitude checkout flight Sept. 8, 1999, over Rogers Dry Lake adjacent to NASA's Dryden Flight Research Center in the Southern California desert. The initial flight series was flown on battery power as a risk-reduction measure. In all, six flights were flown in the Helios Protoype's initial development series. In upgrading the Centurion to the Helios Prototype configuration, AeroVironment added a sixth wing section and a fifth landing gear pod, among other improvements. The additional wingsp

  11. Characterization of the Li beam probe with a beam profile monitor on JETa)

    NASA Astrophysics Data System (ADS)

    Nedzelskiy, I. S.; Korotkov, A.; Brix, M.; Morgan, P.; Vince, J.; Jet Efda Contributors

    2010-10-01

    The lithium beam probe (LBP) is widely used for measurements of the electron density in the edge plasma of magnetically confined fusion experiments. The quality of LBP data strongly depends on the stability and profile shape of the beam. The main beam parameters are as follows: beam energy, beam intensity, beam profile, beam divergence, and the neutralization efficiency. For improved monitoring of the beam parameters, a beam profile monitor (BPM) from the National Electrostatics Corporation (NEC) has been installed in the Li beam line at JET. In the NEC BPM, a single grounded wire formed into a 45° segment of a helix is rotated by a motor about the axis of the helix. During each full revolution, the wire sweeps twice across the beam to give X and Y profiles. In this paper, we will describe the properties of the JET Li beam as measured with the BPM and demonstrate that it facilitates rapid optimization of the gun performance.

  12. ACCELERATORS: Beam based alignment of the SSRF storage ring

    NASA Astrophysics Data System (ADS)

    Zhang, Man-Zhou; Li, Hao-Hu; Jiang, Bo-Cheng; Liu, Gui-Min; Li, De-Ming

    2009-04-01

    There are 140 beam position monitors (BPMs) in the Shanghai Synchrotron Radiation Facility (SSRF) storage ring used for measuring the closed orbit. As the BPM pickup electrodes are assembled directly on the vacuum chamber, it is important to calibrate the electrical center offset of the BPM to an adjacent quadrupole magnetic center. A beam based alignment (BBA) method which varies individual quadrupole magnet strength and observes its effects on the orbit is used to measure the BPM offsets in both the horizontal and vertical planes. It is a completely automated technique with various data processing methods. There are several parameters such as the strength change of the correctors and the quadrupoles which should be chosen carefully in real measurement. After several rounds of BBA measurement and closed orbit correction, these offsets are set to an accuracy better than 10 μm. In this paper we present the method of beam based calibration of BPMs, the experimental results of the SSRF storage ring, and the error analysis.

  13. Arabidopsis thaliana BTB/ POZ-MATH proteins interact with members of the ERF/AP2 transcription factor family.

    PubMed

    Weber, Henriette; Hellmann, Hanjo

    2009-11-01

    In Arabidopsis thaliana, the BTB/POZ-MATH (BPM) proteins comprise a small family of six members. They have been described previously to use their broad complex, tram track, bric-a-brac/POX virus and zinc finger (BTB/POZ) domain to assemble with CUL3a and CUL3b and potentially to serve as substrate adaptors to cullin-based E3-ligases in plants. In this article, we show that BPMs can also assemble with members of the ethylene response factor/Apetala2 transcription factor family, and that this is mediated by their meprin and TRAF (tumor necrosis factor receptor-associated factor) homology (MATH) domain. In addition, we provide a detailed description of BPM gene expression patterns in different tissues and on abiotic stress treatments, as well as their subcellular localization. This work connects, for the first time, BPM proteins with ethylene response factor/Apetala2 family members, which is likely to represent a novel regulatory mechanism of transcriptional control.

  14. Characterization of the International Linear Collider damping ring optics

    NASA Astrophysics Data System (ADS)

    Shanks, J.; Rubin, D. L.; Sagan, D.

    2014-10-01

    A method is presented for characterizing the emittance dilution and dynamic aperture for an arbitrary closed lattice that includes guide field magnet errors, multipole errors and misalignments. This method, developed and tested at the Cornell Electron Storage Ring Test Accelerator (CesrTA), has been applied to the damping ring lattice for the International Linear Collider (ILC). The effectiveness of beam based emittance tuning is limited by beam position monitor (BPM) measurement errors, number of corrector magnets and their placement, and correction algorithm. The specifications for damping ring magnet alignment, multipole errors, number of BPMs, and precision in BPM measurements are shown to be consistent with the required emittances and dynamic aperture. The methodology is then used to determine the minimum number of position monitors that is required to achieve the emittance targets, and how that minimum depends on the location of the BPMs. Similarly, the maximum tolerable multipole errors are evaluated. Finally, the robustness of each BPM configuration with respect to random failures is explored.

  15. Tilting-induced decrease in systolic blood pressure in bedridden hypertensive elderly inpatients: effects of azelnidipine.

    PubMed

    Morimoto, Shigeto; Takahashi, Takashi; Okaishi, Kohya; Nakahashi, Takeshi; Nomura, Kohji; Kanda, Tsugiyasu; Okuro, Masashi; Murai, Hiroshi; Nishino, Tomoichi; Matsumoto, Masayuki

    2006-12-01

    The object of this study was to examine blood pressure (BP) variability due to postural change in elderly hypertensive patients. The subjects studied were 154 elderly inpatients in a hospital for the elderly (48 male and 106 female; median age: 82 years), consisting of age- and sex-matched bedridden (n=39) and non-bedridden (n=39) normotensive controls and bedridden (n=38) and non-bedridden (n=38) hypertensive patients. BP and pulse rate (PR) were measured in the supine position, then again after a 2-min, 45 deg head-up tilt with the legs horizontal. The decrease in systolic BP (SBP) on tilting in the bedridden hypertensive group (median: -10 mmHg; range: -32 to 9 mmHg) was significantly (p<0.008) greater than those in the other three groups. Monotherapy with azeinidipine, a long-acting calcium channel blocker, for 3 months not only significantly reduced the basal BP and PR of hypertensive patients in the two groups, but also significantly (p<0.05) attenuated the tilt-induced decrease in the SBP to -3 mmHg (-19 to 25 mmHg) and enhanced the change in PR from -1 bpm (-10 to 7 bpm) to 1 bpm (-4 to 23 bpm) in the bedridden hypertensive group. Our findings indicate that tilt-induced decrease in SBP is a rather common phenomenon in bedridden elderly hypertensive patients, and that treatment with azelnidipine attenuates tilt-induced decrease in SBP, probably through an improvement of baroreceptor sensitivity.

  16. Inflight workload assessment: comparison of subjective and physiological measurements.

    PubMed

    Lee, Yung-Hui; Liu, Bor-Shong

    2003-10-01

    Assessment of pilot workload during flight is an important aviation safety consideration. The aim of this study was to assess inflight pilot workload using both physiological and multidimensional subjective-ratings measurements (heart rate and NASA Task Load Index, respectively), comparing relative sensitivity during the four phases of flight: take-off, cruise, approach, and landing. Ten male pilots volunteered to participate in the trials, which took place in a Boeing 747-400 flight simulator. Electrocardiography was performed throughout the test using the portable Cardiovis ECG system. Mean heart rate (HR) and incremental heart rate (delta HR) were considered indices of physiological workload. Peak HR was observed during take-off (83.2 bpm) and landing (88.6 bpm); moreover, delta HR was also greatest (14.2 bpm and 18.8 bpm). The Task Load Index (TLX) scale revealed that mental and performance demands were essential components of workload during flight. In addition, temporal demand was an important component of workload during take-off and physical demand was significant during cruise. Analysis of correlation revealed that the delta HR is significantly related to TLX scores (r = 0.81, n = 40). Management of the individual sources of stress, which tend to become predominant during different flight phases, should be emphasized in periodic recurrent training. For example, a pilot must be trained to cope with the increased temporal stresses associated with take-off. In addition, the recommendations will be concerned with maintaining vigilance, task allocation between pilots, and inflight rest during long-haul cruise.

  17. New approach for point pollution source identification in rivers based on the backward probability method.

    PubMed

    Wang, Jiabiao; Zhao, Jianshi; Lei, Xiaohui; Wang, Hao

    2018-06-13

    Pollution risk from the discharge of industrial waste or accidental spills during transportation poses a considerable threat to the security of rivers. The ability to quickly identify the pollution source is extremely important to enable emergency disposal of pollutants. This study proposes a new approach for point source identification of sudden water pollution in rivers, which aims to determine where (source location), when (release time) and how much pollutant (released mass) was introduced into the river. Based on the backward probability method (BPM) and the linear regression model (LR), the proposed LR-BPM converts the ill-posed problem of source identification into an optimization model, which is solved using a Differential Evolution Algorithm (DEA). The decoupled parameters of released mass are not dependent on prior information, which improves the identification efficiency. A hypothetical case study with a different number of pollution sources was conducted to test the proposed approach, and the largest relative errors for identified location, release time, and released mass in all tests were not greater than 10%. Uncertainty in the LR-BPM is mainly due to a problem with model equifinality, but averaging the results of repeated tests greatly reduces errors. Furthermore, increasing the gauging sections further improves identification results. A real-world case study examines the applicability of the LR-BPM in practice, where it is demonstrated to be more accurate and time-saving than two existing approaches, Bayesian-MCMC and basic DEA. Copyright © 2018 Elsevier Ltd. All rights reserved.

  18. Validation of Biofeedback Wearables for Photoplethysmographic Heart Rate Tracking

    PubMed Central

    Jo, Edward; Lewis, Kiana; Directo, Dean; Kim, Michael J.; Dolezal, Brett A.

    2016-01-01

    The purpose of this study was to examine the validity of HR measurements by two commercial-use activity trackers in comparison to ECG. Twenty-four healthy participants underwent the same 77-minute protocol during a single visit. Each participant completed an initial rest period of 15 minutes followed by 5 minute periods of each of the following activities: 60W and 120W cycling, walking, jogging, running, resisted arm raises, resisted lunges, and isometric plank. In between each exercise task was a 5-minute rest period. Each subject wore a Basis Peak (BPk) on one wrist and a Fitbit Charge HR (FB) on the opposite wrist. Criterion measurement of HR was administered by 12-lead ECG. Time synced data from each device and ECG were concurrently and electronically acquired throughout the entire 77-minute protocol. When examining data in aggregate, there was a strong correlation between BPk and ECG for HR (r = 0.92, p < 0.001) with a mean bias of -2.5 bpm (95% LoA 19.3, -24.4). The FB demonstrated a moderately strong correlation with ECG for HR (r = 0.83, p < 0.001) with an average mean bias of -8.8 bpm (95% LoA 24.2, -41.8). During physical efforts eliciting ECG HR > 116 bpm, the BPk demonstrated an r = 0.77 and mean bias = -4.9 bpm (95% LoA 21.3, -31.0) while the FB demonstrated an r = 0.58 and mean bias = -12.7 bpm (95% LoA 28.6, -54.0). The BPk satisfied validity criteria for HR monitors, however showed a marginal decline in accuracy with increasing physical effort (ECG HR > 116 bpm). The FB failed to satisfy validity criteria and demonstrated a substantial decrease in accuracy during higher exercise intensities. Key points Modern day wearable multi-sensor activity trackers incorporate reflective photoplethymography (PPG) for heart rate detection and monitoring at the dorsal wrist. This study examined the validity of two PPG-based activity trackers, the Basis Peak and Fitbit Charge HR. The Basis Peak performed with accuracy compared with ECG and results substantiate validation of heart rate measurements. There was a slight decrease in performance during higher levels of physical exertion. The Fitbit Charge HR performed with poor accuracy compared with ECG especially during higher physical exertion and specific exercise tasks. The Fitbit Charge HR was not validated for heart rate monitoring, although better accuracy was observed during resting or recovery conditions. PMID:27803634

  19. Exposure to air pollution near a steel plant and effects on cardiovascular physiology: a randomized crossover study.

    PubMed

    Liu, Ling; Kauri, Lisa Marie; Mahmud, Mamun; Weichenthal, Scott; Cakmak, Sabit; Shutt, Robin; You, Hongyu; Thomson, Errol; Vincent, Renaud; Kumarathasan, Premkumari; Broad, Gayle; Dales, Robert

    2014-03-01

    Iron and steel industry is an important source of air pollution emissions. Few studies have investigated cardiovascular effects of air pollutants emitted from steel plants. We examined the influence of outdoor air pollution in the vicinity of a steel plant on cardiovascular physiology in Sault Ste. Marie, Canada. Sixty-one healthy, non-smoking subjects (females/males=33/28, median age 22 years) spent 5 consecutive 8-hour days outdoors in a residential area neighbouring a steel plant, or on a college campus approximately 5 kilometres away from the plant, and then crossed over to the other site with a 9-day washout. Mid day, subjects underwent daily 30-minute moderate intensity exercise. Blood pressure (BP) and pulse rate were determined daily and post exercise at both sites. Flow-mediated vasodilation (FMD) was determined at the site near the plant. Air pollution was monitored at both sites. Mixed-effects regressions were run for statistical associations, adjusting for weather variables. Concentrations of ultrafine particles, sulphur dioxide (SO2), nitrogen dioxide (NO2) and carbon monoxide (CO) were 50-100% higher at the site near the plant than at the college site, with minor differences in temperature, humidity, and concentrations of particulate matter ≤2.5 μm in size (PM2.5) and ozone (O3). Resting pulse rate [mean (95% confidence interval)] was moderately higher near the steel plant [+1.53 bpm (0.31, 2.78)] than at the college site, male subjects having the highest pulse rate elevation [+2.77 bpm (0.78, 4.76)]. Resting systolic and diastolic BP and pulse pressure, and post-exercise BP and pulse rate were not significantly different between two sites. Interquartile range concentrations of SO2 (2.9 ppb), NO2 (5.0 ppb) and CO (0.2 ppm) were associated with increased pulse rate [0.19 bpm (-0.00, 0.38), 0.86 bpm (0.03, 1.68), and 0.11 bpm (0.00, 0.22), respectively], ultrafine particles (10,256 count/cm(3)) associated with increased pulse pressure [0.85 mmHg (0.23, 1.48)], and NO2 and CO inversely associated with FMD [-0.14% (-0.31, 0.02), -0.02% (-0.03, -0.00), respectively]. SO2 during exercise was associated with increased pulse rate [0.26 bpm (0.01, 0.51)]. Air quality in residential areas near steel plants may influence cardiovascular physiology. Copyright © 2013 Elsevier GmbH. All rights reserved.

  20. New association of bone morphogenetic protein 4 concentrations with fat distribution in obesity and Exenatide intervention on it.

    PubMed

    Wang, Xingchun; Chen, Jiaqi; Li, Liang; Zhu, Cui Ling; Gao, Jingyang; Rampersad, Sharvan; Bu, Le; Qu, Shen

    2017-04-04

    Bone morphogenetic protein 4 (BMP-4) has been proven to regulate white adipogensis. We aimed to demonstrate the correlation of BMP-4 with fat distribution and Exenatide treatment on it. We enrolled 69 obese patients. Anthropometric and metabolic indexes were collected. Fat distribution was measured by dual-energy X-ray absorptiometry. BPM-4 levels were assessed using enzyme-link immunosorbent assay kit. 30 obese patients were treated with Exenatide twice a day. Change in body weight, metabolic-related indices and BPM-4 levels were evaluated after 18 weeks. 1) The mean(±SD) BMP-4 levels were 763.98 ± 324.11 pg/ml in the obese. BPM-4 levels were significantly positively correlated with estimated visceral adipose tissue mass in all subjects and also in females (r = 0.377, r = 0.625, respectively,all P < 0.05). BPM-4 levels were also significantly positively correlated with body mass index, hip circumference and total fat% in females (r = 0.375,r = 0.429,r = 0.493,respectively, all P < 0.05). BPM-4 levels were negatively correlated with total cholesterol(TC) in all subjects and males also (r = -0.373,r = -0.332,respectively, all P < 0.05). BPM-4 levels were also significantly positively correlated with free triiodothyronine in males (r = 0.441, P < 0.05). 3) Multivariate analyses showed that TC was risk factor of BMP-4 concentration in males and Est.VAT Area was risk factor of BMP-4 levels in females. 4) BMP-4 levels were significantly higher in the obesity with slightly increased thyroid stimulating hormone(TSH) than the obesity without slightly increased TSH (902.08 ± 354.74 pg/ml vs. 720.24 ± 306.41 pg/ml, P < 0.05). 5) Exenatide treatment leads to a significant decreased in BMP-4 from 860.05 ± 352.65 pg/ml to 649.44 + 277.49 pg/ml independent of weight loss(P < 0.05). BMP-4 levels were associated with the visceral adipose tissue and may play a certain role in fat distribution and subclinical hypothyroidism in obesity. Exenatide treatment reduced BMP-4 levels independent of weight loss. Clinicaltrials.gov Identifier: NCT02118376 , Registered 16 April.

Top