The impact of age on the art of mammography and how to adapt accordingly.
Lake, B; Cielecki, L; Williams, S; Worrall, C; Metelko, M
2017-11-01
Breast cancer is increasingly a disease of the elderly, and combined with the NHS Breast Screening Extension means that more elderly patients are having mammography. Increasing age can make mammography more technically difficult. This is a technical note detailing the results of a local audit which may be of interest due to potential service implications. A retrospective audit of the first year of screening extension of The Shropshire Breast Screening Programme. Aims to collect data on patient demographics and describe the technical adaptations developed in Shropshire. Breast screening extension has increased by 2.5 times the number of women aged 70-74 screened, and doubled the overall numbers of women over 70 screened. Significantly more older patients are being screened to present technical challenges to a screening programme. Data was obtained from a month of screening showed that 29% of patients over 70 needed extra time for positioning. Reasons included 22% difficulty in obtaining adequate positioning and 15% needed a relative to aid with consent. In the Shropshire screening programme different technical adaptations have been developed and are key to ensuring adequate images. These include double appointments, two radiographers, thorough assessment, steeper angles, seated examinations, from-below imaging and pre-planning for subsequent screen. Significantly more older women are having breast screening due to the increasing incidence of breast cancer and the Breast Screening Programme extension. Increasing age can significantly increase time taken for adequate imaging and present technical challenges. Development of technical adaptations to art of mammography is key to achieve adequate images. Copyright © 2017 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.
Mauri, Giovanni; Sconfienza, Luca Maria; Pescatori, Lorenzo Carlo; Fedeli, Maria Paola; Alì, Marco; Di Leo, Giovanni; Sardanelli, Francesco
2017-08-01
To systematically review studies concerning imaging-guided minimally-invasive breast cancer treatments. An online database search was performed for English-language articles evaluating percutaneous breast cancer ablation. Pooled data and 95% confidence intervals (CIs) were calculated. Technical success, technique efficacy, minor and major complications were analysed, including ablation technique subgroup analysis and effect of tumour size on outcome. Forty-five studies were analysed, including 1,156 patients and 1,168 lesions. Radiofrequency (n=577; 50%), microwaves (n=78; 7%), laser (n=227; 19%), cryoablation (n=156; 13%) and high-intensity focused ultrasound (HIFU, n=129; 11%) were used. Pooled technical success was 96% (95%CI 94-97%) [laser=98% (95-99%); HIFU=96% (90-98%); radiofrequency=96% (93-97%); cryoablation=95% (90-98%); microwave=93% (81-98%)]. Pooled technique efficacy was 75% (67-81%) [radiofrequency=82% (74-88); cryoablation=75% (51-90); laser=59% (35-79); HIFU=49% (26-74)]. Major complications pooled rate was 6% (4-8). Minor complications pooled rate was 8% (5-13%). Differences between techniques were not significant for technical success (p=0.449), major complications (p=0.181) or minor complications (p=0.762), but significant for technique efficacy (p=0.009). Tumour size did not impact on variables (p>0.142). Imaging-guided percutaneous ablation techniques of breast cancer have a high rate of technical success, while technique efficacy remains suboptimal. Complication rates are relatively low. • Imaging-guided ablation techniques for breast cancer are 96% technically successful. • Overall technique efficacy rate is 75% but largely inhomogeneous among studies. • Overall major and minor complication rates are low (6-8%).
Diffusion-weighted Breast MRI: Clinical Applications and Emerging Techniques
Partridge, Savannah C.; Nissan, Noam; Rahbar, Habib; Kitsch, Averi E.; Sigmund, Eric E.
2016-01-01
Diffusion weighted MRI (DWI) holds potential to improve the detection and biological characterization of breast cancer. DWI is increasingly being incorporated into breast MRI protocols to address some of the shortcomings of routine clinical breast MRI. Potential benefits include improved differentiation of benign and malignant breast lesions, assessment and prediction of therapeutic efficacy, and non-contrast detection of breast cancer. The breast presents a unique imaging environment with significant physiologic and inter-subject variations, as well as specific challenges to achieving reliable high quality diffusion weighted MR images. Technical innovations are helping to overcome many of the image quality issues that have limited widespread use of DWI for breast imaging. Advanced modeling approaches to further characterize tissue perfusion, complexity, and glandular organization may expand knowledge and yield improved diagnostic tools. PMID:27690173
NASA Astrophysics Data System (ADS)
Zhang, Guozhi; Petrov, Dimitar; Marshall, Nicholas; Bosmans, Hilde
2017-03-01
Digital breast tomosynthesis (DBT) is a relatively new diagnostic imaging modality for women. Currently, various models of DBT systems are available on the market and the number of installations is rapidly increasing. EUREF, the European Reference Organization for Quality Assured Breast Screening and Diagnostic Services, has proposed a preliminary Guideline - protocol for the quality control of the physical and technical aspects of digital breast tomosynthesis systems, with an ultimate aim of providing limiting values guaranteeing proper performance for different applications of DBT. In this work, we introduce an adaptive toolkit developed in accordance with this guideline to facilitate the process of image quality evaluation in DBT performance test. This toolkit implements robust algorithms to quantify various technical parameters of DBT images and provides a convenient user interface in practice. Each test is built into a separate module with configurations set corresponding to the European guideline, which can be easily adapted to different settings and extended with additional tests. This toolkit largely improves the efficiency for image quality evaluation of DBT. It is also going to evolve with the development of protocols in quality control of DBT systems.
Hellerhoff, K
2010-11-01
In recent years digital full field mammography has increasingly replaced conventional film mammography. High quality imaging is guaranteed by high quantum efficiency and very good contrast resolution with optimized dosing even for women with dense glandular tissue. However, digital mammography remains a projection procedure by which overlapping tissue limits the detectability of subtle alterations. Tomosynthesis is a procedure developed from digital mammography for slice examination of breasts which eliminates the effects of overlapping tissue and allows 3D imaging of breasts. A curved movement of the X-ray tube during scanning allows the acquisition of many 2D images from different angles. Subseqently, reconstruction algorithms employing a shift and add method improve the recognition of details at a defined level and at the same time eliminate smear artefacts due to overlapping structures. The total dose corresponds to that of conventional mammography imaging. The technical procedure, including the number of levels, suitable anodes/filter combinations, angle regions of images and selection of reconstruction algorithms, is presently undergoing optimization. Previous studies on the clinical value of tomosynthesis have examined screening parameters, such as recall rate and detection rate as well as information on tumor extent for histologically proven breast tumors. More advanced techniques, such as contrast medium-enhanced tomosynthesis, are presently under development and dual-energy imaging is of particular importance.
Schaefgen, Benedikt; Heil, Joerg; Barr, Richard G; Radicke, Marcus; Harcos, Aba; Gomez, Christina; Stieber, Anne; Hennigs, André; von Au, Alexandra; Spratte, Julia; Rauch, Geraldine; Rom, Joachim; Schütz, Florian; Sohn, Christof; Golatta, Michael
2018-06-01
To determine the feasibility of a prototype device combining 3D-automated breast ultrasound (ABVS) and digital breast tomosynthesis in a single device to detect and characterize breast lesions. In this prospective feasibility study, the FUSION-X-US prototype was used to perform digital breast tomosynthesis and ABVS in 23 patients with an indication for tomosynthesis based on current guidelines after clinical examination and standard imaging. The ABVS and tomosynthesis images of the prototype were interpreted separately by two blinded experts. The study compares the detection and BI-RADS® scores of breast lesions using only the tomosynthesis and ABVS data from the FUSION-X-US prototype to the results of the complete diagnostic workup. Image acquisition and processing by the prototype was fast and accurate, with some limitations in ultrasound coverage and image quality. In the diagnostic workup, 29 solid lesions (23 benign, including three cases with microcalcifications, and six malignant lesions) were identified. Using the prototype, all malignant lesions were detected and classified as malignant or suspicious by both investigators. Solid breast lesions can be localized accurately and fast by the Fusion-X-US system. Technical improvements of the ultrasound image quality and ultrasound coverage are needed to further study this new device. The prototype combines tomosynthesis and automated 3D-ultrasound (ABVS) in one device. It allows accurate detection of malignant lesions, directly correlating tomosynthesis and ABVS data. The diagnostic evaluation of the prototype-acquired data was interpreter-independent. The prototype provides a time-efficient and technically reliable diagnostic procedure. The combination of tomosynthesis and ABVS is a promising diagnostic approach.
Mammographic density estimation with automated volumetric breast density measurement.
Ko, Su Yeon; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung
2014-01-01
To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.
Imaging of breast cancer with mid- and long-wave infrared camera.
Joro, R; Lääperi, A-L; Dastidar, P; Soimakallio, S; Kuukasjärvi, T; Toivonen, T; Saaristo, R; Järvenpää, R
2008-01-01
In this novel study the breasts of 15 women with palpable breast cancer were preoperatively imaged with three technically different infrared (IR) cameras - micro bolometer (MB), quantum well (QWIP) and photo voltaic (PV) - to compare their ability to differentiate breast cancer from normal tissue. The IR images were processed, the data for frequency analysis were collected from dynamic IR images by pixel-based analysis and from each image selectively windowed regional analysis was carried out, based on angiogenesis and nitric oxide production of cancer tissue causing vasomotor and cardiogenic frequency differences compared to normal tissue. Our results show that the GaAs QWIP camera and the InSb PV camera demonstrate the frequency difference between normal and cancerous breast tissue; the PV camera more clearly. With selected image processing operations more detailed frequency analyses could be applied to the suspicious area. The MB camera was not suitable for tissue differentiation, as the difference between noise and effective signal was unsatisfactory.
Rjosk-Dendorfer, D; Reichelt, A; Clevert, D-A
2014-03-01
In recent years the use of elastography in addition to sonography has become a routine clinical tool for the characterization of breast masses. Whereas free hand compression elastography results in qualitative imaging of tissue stiffness due to induced compression, shear wave elastography displays quantitative information of tissue displacement. Recent studies have investigated the use of elastography in addition to sonography and improvement of specificity in differentiating benign from malignant breast masses could be shown. Therefore, additional use of elastography could help to reduce the number of unnecessary biopsies in benign breast lesions especially in category IV lesions of the ultrasound breast imaging reporting data system (US-BI-RADS).
Mammographic Density Estimation with Automated Volumetric Breast Density Measurement
Ko, Su Yeon; Kim, Eun-Kyung; Kim, Min Jung
2014-01-01
Objective To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. Materials and Methods In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. Results The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). Conclusion There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density. PMID:24843235
Broeders, Mireille J M; Ten Voorde, Marloes; Veldkamp, Wouter J H; van Engen, Ruben E; van Landsveld-Verhoeven, Cary; 't Jong-Gunneman, Machteld N L; de Win, Jos; Greve, Kitty Droogh-de; Paap, Ellen; den Heeten, Gerard J
2015-03-01
To compare pain, projected breast area, radiation dose and image quality between flexible (FP) and rigid (RP) breast compression paddles. The study was conducted in a Dutch mammographic screening unit (288 women). To compare both paddles one additional image with RP was made, consisting of either a mediolateral-oblique (MLO) or craniocaudal-view (CC). Pain experience was scored using the Numeric Rating Scale (NRS). Projected breast area was estimated using computer software. Radiation dose was estimated using the model by Dance. Image quality was reviewed by three radiologists and three radiographers. There was no difference in pain experience between both paddles (mean difference NRS: 0.08 ± 0.08, p = 0.32). Mean radiation dose was 4.5 % lower with FP (0.09 ± 0.01 p = 0.00). On MLO-images, the projected breast area was 0.79 % larger with FP. Paired evaluation of image quality indicated that FP removed fibroglandular tissue from the image area and reduced contrast in the clinically relevant retroglandular area at chest wall side. Although FP performed slightly better in the projected breast area, it moved breast tissue from the image area at chest wall side. RP showed better contrast, especially in the retroglandular area. We therefore recommend the use of RP for standard MLO and CC views.
Cardiff, Robert D; Hubbard, Neil E; Engelberg, Jesse A; Munn, Robert J; Miller, Claramae H; Walls, Judith E; Chen, Jane Q; Velásquez-García, Héctor A; Galvez, Jose J; Bell, Katie J; Beckett, Laurel A; Li, Yue-Ju; Borowsky, Alexander D
2013-01-01
Quantitative Image Analysis (QIA) of digitized whole slide images for morphometric parameters and immunohistochemistry of breast cancer antigens was used to evaluate the technical reproducibility, biological variability, and intratumoral heterogeneity in three transplantable mouse mammary tumor models of human breast cancer. The relative preservation of structure and immunogenicity of the three mouse models and three human breast cancers was also compared when fixed with representatives of four distinct classes of fixatives. The three mouse mammary tumor cell models were an ER + /PR + model (SSM2), a Her2 + model (NDL), and a triple negative model (MET1). The four breast cancer antigens were ER, PR, Her2, and Ki67. The fixatives included examples of (1) strong cross-linkers, (2) weak cross-linkers, (3) coagulants, and (4) combination fixatives. Each parameter was quantitatively analyzed using modified Aperio Technologies ImageScope algorithms. Careful pre-analytical adjustments to the algorithms were required to provide accurate results. The QIA permitted rigorous statistical analysis of results and grading by rank order. The analyses suggested excellent technical reproducibility and confirmed biological heterogeneity within each tumor. The strong cross-linker fixatives, such as formalin, consistently ranked higher than weak cross-linker, coagulant and combination fixatives in both the morphometric and immunohistochemical parameters. PMID:23399853
DeMartini, Wendy B; Ichikawa, Laura; Yankaskas, Bonnie C; Buist, Diana; Kerlikowske, Karla; Geller, Berta; Onega, Tracy; Rosenberg, Robert D; Lehman, Constance D
2010-11-01
MRI is increasingly used for the detection of breast carcinoma. Little is known about breast MRI techniques among community practice facilities. The aim of this study was to evaluate equipment and acquisition techniques used by community facilities across the United States, including compliance with minimum standards by the ACRIN® 6667 Trial and the European Society of Breast Imaging. Breast Cancer Surveillance Consortium facilities performing breast MRI were identified and queried by survey regarding breast MRI equipment and technical parameters. Variables included scanner field strength, coil type, acquisition coverage, slice thickness, and the timing of the initial postcontrast sequence. Results were tallied and percentages of facilities meeting ACRIN® and European Society of Breast Imaging standards were calculated. From 23 facilities performing breast MRI, results were obtained from 14 (61%) facilities with 16 MRI scanners reporting 18 imaging parameters. Compliance with equipment recommendations of ≥1.5-T field strength was 94% and of a dedicated breast coil was 100%. Eighty-three percent of acquisitions used bilateral postcontrast techniques, and 78% used slice thickness≤3 mm. The timing of initial postcontrast sequences ranged from 58 seconds to 8 minutes 30 seconds, with 63% meeting recommendations for completion within 4 minutes. Nearly all surveyed facilities met ACRIN and European Society of Breast Imaging standards for breast MRI equipment. The majority met standards for acquisition parameters, although techniques varied, in particular for the timing of initial postcontrast imaging. Further guidelines by the ACR Breast MRI Accreditation Program will be of importance in facilitating standardized and high-quality breast MRI. Copyright © 2010 American College of Radiology. Published by Elsevier Inc. All rights reserved.
Dong, S L; Su, J L; Yeh, Y H; Chu, T C; Lin, Y C; Chuang, K S
2011-04-01
Imaging breasts with a short chest wall to nipple distance (CWND) using a traditional mammographic X-ray unit is a technical challenge for mammographers. The purpose of this study is the development of an imaging-planning program to assist in determination of imaging parameters of screen/film (SF) and computed radiography (CR) mammography for short CWND breasts. A traditional mammographic X-ray unit (Mammomat 3000, Siemens, Munich, Germany) was employed. The imaging-planning program was developed by combining the compressed breast thickness correction, the equivalent polymethylmethacrylate thickness assessment for breasts and the tube loading (mAs) measurement. Both phantom exposures and a total of 597 exposures were used for examining the imaging-planning program. Results of the phantom study show that the tube loading rapidly decreased with the CWND when the automatic exposure control (AEC) detector was not fully covered by the phantom. For patient exposures with the AEC fully covered by breast tissue, the average fractional tube loadings, defined as the ratio of the predicted mAs using the imaging-planning program and mAs of the mammogram, were 1.10 and 1.07 for SF and CR mammograms, respectively. The predicted mAs values were comparable to the mAs values, as determined by the AEC. By applying the imaging-planning program in clinical practice, the experiential dependence of the mammographer for determination of the imaging parameters for short CWND breasts is minimised.
NASA Astrophysics Data System (ADS)
Rodríguez-Ruiz, Alejandro; Agasthya, Greeshma A.; Sechopoulos, Ioannis
2017-09-01
To characterize and develop a patient-based 3D model of the compressed breast undergoing mammography and breast tomosynthesis. During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3D breast surface imaging with structured light (SL) during breast compression, along with simultaneous acquisition of a tomosynthesis image. A pair of SL systems were used to acquire 3D surface images by projecting 24 different patterns onto the compressed breast and capturing their reflection off the breast surface in approximately 12-16 s. The 3D surface was characterized and modeled via principal component analysis. The resulting surface model was combined with a previously developed 2D model of projected compressed breast shapes to generate a full 3D model. Data from ten patients were discarded due to technical problems during image acquisition. The maximum breast thickness (found at the chest-wall) had an average value of 56 mm, and decreased 13% towards the nipple (breast tilt angle of 5.2°). The portion of the breast not in contact with the compression paddle or the support table extended on average 17 mm, 18% of the chest-wall to nipple distance. The outermost point along the breast surface lies below the midline of the total thickness. A complete 3D model of compressed breast shapes was created and implemented as a software application available for download, capable of generating new random realistic 3D shapes of breasts undergoing compression. Accurate characterization and modeling of the breast curvature and shape was achieved and will be used for various image processing and clinical tasks.
Merckel, Laura G; Bartels, Lambertus W; Köhler, Max O; van den Bongard, H J G Desirée; Deckers, Roel; Mali, Willem P Th M; Binkert, Christoph A; Moonen, Chrit T; Gilhuijs, Kenneth G A; van den Bosch, Maurice A A J
2013-04-01
Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.
Onishi, Natsuko; Kataoka, Masako; Kanao, Shotaro; Sagawa, Hajime; Iima, Mami; Nickel, Marcel Dominik; Toi, Masakazu; Togashi, Kaori
2018-01-01
To evaluate the feasibility of ultrafast dynamic contrast-enhanced (UF-DCE) magnetic resonance imaging (MRI) with compressed sensing (CS) for the separate identification of breast arteries/veins and perform temporal evaluations of breast arteries and veins with a focus on the association with ipsilateral cancers. Our Institutional Review Board approved this study with retrospective design. Twenty-five female patients who underwent UF-DCE MRI at 3T were included. UF-DCE MRI consisting of 20 continuous frames was acquired using a prototype 3D gradient-echo volumetric interpolated breath-hold sequence including a CS reconstruction: temporal resolution, 3.65 sec/frame; spatial resolution, 0.9 × 1.3 × 2.5 mm. Two readers analyzed 19 maximum intensity projection images reconstructed from subtracted images, separately identified breast arteries/veins and the earliest frame in which they were respectively visualized, and calculated the time interval between arterial and venous visualization (A-V interval) for each breast. In total, 49 breasts including 31 lesions (breast cancer, 16; benign lesion, 15) were identified. In 39 of the 49 breasts (breasts with cancers, 16; breasts with benign lesions, 10; breasts with no lesions, 13), both breast arteries and veins were separately identified. The A-V intervals for breasts with cancers were significantly shorter than those for breasts with benign lesions (P = 0.043) and no lesions (P = 0.007). UF-DCE MRI using CS enables the separate identification of breast arteries/veins. Temporal evaluations calculating the time interval between arterial and venous visualization might be helpful in the differentiation of ipsilateral breast cancers from benign lesions. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018;47:97-104. © 2017 International Society for Magnetic Resonance in Medicine.
Feasibility of telemammography as biomedical application for breast imaging
NASA Astrophysics Data System (ADS)
Beckerman, Barbara G.; Batsell, Stephen G.; MacIntyre, Lawrence P.; Sarraf, Hamed S.; Gleason, Shaun S.; Schnall, Mitchell D.
1999-07-01
Mammographic screening is an important tool in the early detection of breast cancer. The migration of mammography from the current mode of x-ray mammography using a film screen image detector and display to a digital technology provides an opportunity to improve access and performance of breast cancer screening. The sheer size and volume of the typical screening exam, the need to have previous screening data readily available, and the need to view other breast imaging data together to provide a common consensus and to plan treatment, make telemammography an ideal application for breast imaging. For telemammography to be a viable option, it must overcome the technical challenges related to transmission, archiving, management, processing and retrieval of large data sets. Researchers from the University of Pennsylvania, the University of Chicago and Lockheed Martin Energy Systems/Oak Ridge National Laboratory have developed a framework for transmission of large-scale medical images over high-speed networks, leveraged existing high-speed networks between research and medical facilities; tested the feasibility of point-to-point transmission of mammographic images in a near-real time environment; evaluated network performance and transmission scenarios; and investigated the impact of image preprocessing on an experimental computer-aided diagnosis system. Results of the initial study are reported here.
The Changing World of Breast Cancer
Kuhl, Christiane K.
2015-01-01
Abstract Compared with other fields of medicine, there is hardly an area that has seen such fast development as the world of breast cancer. Indeed, the way we treat breast cancer has changed fundamentally over the past decades. Breast imaging has always been an integral part of this change, and it undergoes constant adjustment to new ways of thinking. This relates not only to the technical tools we use for diagnosing breast cancer but also to the way diagnostic information is used to guide treatment. There is a constant change of concepts for and attitudes toward breast cancer, and a constant flux of new ideas, new treatment approaches, and new insights into the molecular and biological behavior of this disease. Clinical breast radiologists and even more so, clinician scientists, interested in breast imaging need to keep abreast with this rapidly changing world. Diagnostic or treatment approaches that are considered useful today may be abandoned tomorrow. Approaches that seem irrelevant or far too extravagant today may prove clinically useful and adequate next year. Radiologists must constantly question what they do, and align their clinical aims and research objectives with the changing needs of contemporary breast oncology. Moreover, knowledge about the past helps better understand present debates and controversies. Accordingly, in this article, we provide an overview on the evolution of breast imaging and breast cancer treatment, describe current areas of research, and offer an outlook regarding the years to come. PMID:26083829
Breast imaging. A practical look at its capabilities and its limitations.
Clark, R; Nemec, L; Love, N
1992-10-01
The film-screen technique is evolving as the standard for mammography. Sonography is the only other method that currently has a defined role in breast imaging. Mammography should be performed at facilities that have received American College of Radiology accreditation or its equivalent, because technical quality assurance is an important part of mammographic practice. Interpretive quality may be assured by outcome audits performed by mammography facilities. Primary care physicians are best suited to encouraging eligible women to undergo screening studies and should consider these recommendations: Refer patients for screening mammography to accredited facilities according to established guidelines. Educate patients about the need for regular screening. Provide annual breast physical examination. Refresh your knowledge on breast health and the techniques of physical examination if necessary. Teach patients breast self-examination techniques. Demand low-cost, high-quality screening mammography; be aware of local variability of charges and quality.
Integration of microwave tomography with magnetic resonance for improved breast imaging
Meaney, Paul M.; Golnabi, Amir H.; Epstein, Neil R.; Geimer, Shireen D.; Fanning, Margaret W.; Weaver, John B.; Paulsen, Keith D.
2013-01-01
Purpose: Breast magnetic resonance imaging is highly sensitive but not very specific for the detection of breast cancer. Opportunities exist to supplement the image acquisition with a more specific modality provided the technical challenges of meeting space limitations inside the bore, restricted breast access, and electromagnetic compatibility requirements can be overcome. Magnetic resonance (MR) and microwave tomography (MT) are complementary and synergistic because the high resolution of MR is used to encode spatial priors on breast geometry and internal parenchymal features that have distinct electrical properties (i.e., fat vs fibroglandular tissue) for microwave tomography. Methods: The authors have overcome integration challenges associated with combining MT with MR to produce a new coregistered, multimodality breast imaging platform—magnetic resonance microwave tomography, including: substantial illumination tank size reduction specific to the confined MR bore diameter, minimization of metal content and composition, reduction of metal artifacts in the MR images, and suppression of unwanted MT multipath signals. Results: MR SNR exceeding 40 dB can be obtained. Proper filtering of MR signals reduces MT data degradation allowing MT SNR of 20 dB to be obtained, which is sufficient for image reconstruction. When MR spatial priors are incorporated into the recovery of MT property estimates, the errors between the recovered versus actual dielectric properties approach 5%. Conclusions: The phantom and human subject exams presented here are the first demonstration of combining MT with MR to improve the accuracy of the reconstructed MT images. PMID:24089930
Shih, Tzu-Ching; Chen, Jeon-Hor; Liu, Dongxu; Nie, Ke; Sun, Lizhi; Lin, Muqing; Chang, Daniel; Nalcioglu, Orhan; Su, Min-Ying
2010-07-21
This study presents a finite element-based computational model to simulate the three-dimensional deformation of a breast and fibroglandular tissues under compression. The simulation was based on 3D MR images of the breast, and craniocaudal and mediolateral oblique compression, as used in mammography, was applied. The geometry of the whole breast and the segmented fibroglandular tissues within the breast were reconstructed using triangular meshes by using the Avizo 6.0 software package. Due to the large deformation in breast compression, a finite element model was used to simulate the nonlinear elastic tissue deformation under compression, using the MSC.Marc software package. The model was tested in four cases. The results showed a higher displacement along the compression direction compared to the other two directions. The compressed breast thickness in these four cases at a compression ratio of 60% was in the range of 5-7 cm, which is a typical range of thickness in mammography. The projection of the fibroglandular tissue mesh at a compression ratio of 60% was compared to the corresponding mammograms of two women, and they demonstrated spatially matched distributions. However, since the compression was based on magnetic resonance imaging (MRI), which has much coarser spatial resolution than the in-plane resolution of mammography, this method is unlikely to generate a synthetic mammogram close to the clinical quality. Whether this model may be used to understand the technical factors that may impact the variations in breast density needs further investigation. Since this method can be applied to simulate compression of the breast at different views and different compression levels, another possible application is to provide a tool for comparing breast images acquired using different imaging modalities--such as MRI, mammography, whole breast ultrasound and molecular imaging--that are performed using different body positions and under different compression conditions.
A software platform for phase contrast x-ray breast imaging research.
Bliznakova, K; Russo, P; Mettivier, G; Requardt, H; Popov, P; Bravin, A; Buliev, I
2015-06-01
To present and validate a computer-based simulation platform dedicated for phase contrast x-ray breast imaging research. The software platform, developed at the Technical University of Varna on the basis of a previously validated x-ray imaging software simulator, comprises modules for object creation and for x-ray image formation. These modules were updated to take into account the refractive index for phase contrast imaging as well as implementation of the Fresnel-Kirchhoff diffraction theory of the propagating x-ray waves. Projection images are generated in an in-line acquisition geometry. To test and validate the platform, several phantoms differing in their complexity were constructed and imaged at 25 keV and 60 keV at the beamline ID17 of the European Synchrotron Radiation Facility. The software platform was used to design computational phantoms that mimic those used in the experimental study and to generate x-ray images in absorption and phase contrast modes. The visual and quantitative results of the validation process showed an overall good correlation between simulated and experimental images and show the potential of this platform for research in phase contrast x-ray imaging of the breast. The application of the platform is demonstrated in a feasibility study for phase contrast images of complex inhomogeneous and anthropomorphic breast phantoms, compared to x-ray images generated in absorption mode. The improved visibility of mammographic structures suggests further investigation and optimisation of phase contrast x-ray breast imaging, especially when abnormalities are present. The software platform can be exploited also for educational purposes. Copyright © 2015 Elsevier Ltd. All rights reserved.
Philadelpho Arantes Pereira, Fernanda; Martins, Gabriela; Gregorio Calas, Maria Julia; Fonseca Torres de Oliveira, Maria Veronica; Gasparetto, Emerson Leandro; Barbosa da Fonseca, Lea Mirian
2013-09-18
Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure's positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast.
Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection.
Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M Iqbal B; Ramli, Abdul Rahman B
2017-01-01
Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed.
Foundation and methodologies in computer-aided diagnosis systems for breast cancer detection
Jalalian, Afsaneh; Mashohor, Syamsiah; Mahmud, Rozi; Karasfi, Babak; Saripan, M. Iqbal B.; Ramli, Abdul Rahman B.
2017-01-01
Breast cancer is the most prevalent cancer that affects women all over the world. Early detection and treatment of breast cancer could decline the mortality rate. Some issues such as technical reasons, which related to imaging quality and human error, increase misdiagnosis of breast cancer by radiologists. Computer-aided detection systems (CADs) are developed to overcome these restrictions and have been studied in many imaging modalities for breast cancer detection in recent years. The CAD systems improve radiologists' performance in finding and discriminating between the normal and abnormal tissues. These procedures are performed only as a double reader but the absolute decisions are still made by the radiologist. In this study, the recent CAD systems for breast cancer detection on different modalities such as mammography, ultrasound, MRI, and biopsy histopathological images are introduced. The foundation of CAD systems generally consist of four stages: Pre-processing, Segmentation, Feature extraction, and Classification. The approaches which applied to design different stages of CAD system are summarised. Advantages and disadvantages of different segmentation, feature extraction and classification techniques are listed. In addition, the impact of imbalanced datasets in classification outcomes and appropriate methods to solve these issues are discussed. As well as, performance evaluation metrics for various stages of breast cancer detection CAD systems are reviewed. PMID:28435432
Shih, Tzu-Ching; Chen, Jeon-Hor; Liu, Dongxu; Nie, Ke; Sun, Lizhi; Lin, Muqing; Chang, Daniel; Nalcioglu, Orhan; Su, Min-Ying
2010-01-01
This study presents a finite element based computational model to simulate the three-dimensional deformation of the breast and the fibroglandular tissues under compression. The simulation was based on 3D MR images of the breast, and the craniocaudal and mediolateral oblique compression as used in mammography was applied. The geometry of whole breast and the segmented fibroglandular tissues within the breast were reconstructed using triangular meshes by using the Avizo® 6.0 software package. Due to the large deformation in breast compression, a finite element model was used to simulate the non-linear elastic tissue deformation under compression, using the MSC.Marc® software package. The model was tested in 4 cases. The results showed a higher displacement along the compression direction compared to the other two directions. The compressed breast thickness in these 4 cases at 60% compression ratio was in the range of 5-7 cm, which is the typical range of thickness in mammography. The projection of the fibroglandular tissue mesh at 60% compression ratio was compared to the corresponding mammograms of two women, and they demonstrated spatially matched distributions. However, since the compression was based on MRI, which has much coarser spatial resolution than the in-plane resolution of mammography, this method is unlikely to generate a synthetic mammogram close to the clinical quality. Whether this model may be used to understand the technical factors that may impact the variations in breast density measurements needs further investigation. Since this method can be applied to simulate compression of the breast at different views and different compression levels, another possible application is to provide a tool for comparing breast images acquired using different imaging modalities – such as MRI, mammography, whole breast ultrasound, and molecular imaging – that are performed using different body positions and different compression conditions. PMID:20601773
Timmers, Janine; Voorde, Marloes Ten; Engen, Ruben E van; Landsveld-Verhoeven, Cary van; Pijnappel, Ruud; Greve, Kitty Droogh-de; Heeten, Gerard J den; Broeders, Mireille J M
2015-10-01
To compare projected breast area, image quality, pain experience and radiation dose between mammography performed with and without radiolucent positioning sheets. 184 women screened in the Dutch breast screening programme (May-June 2012) provided written informed consent to have one additional image taken with positioning sheets. 5 cases were excluded (missing data). Pain was scored using the Numeric Rating Scale. Radiation dose was estimated using the Dance model and projected breast area using computer software. Two radiologists and two radiographers assessed image quality. With positioning sheets significantly more pectoral muscle, lateral and medial breast tissue was projected (CC-views) and more and deeper depicted pectoral muscle (MLO-views). In contrast, visibility of white and darker areas was better on images without positioning sheets, radiologists were therefore better able to detect abnormalities (MLO-views). Women experienced more pain with positioning sheets (MLO-views only, mean difference NRS 0.98; SD 1.71; p=0,00). Mammograms with positioning sheets showed more breast tissue. Increased breast thickness after compression with sheets resulted in less visibility of white and darker areas and thus reduced detection of abnormalities. Also, women experienced more pain (MLO-views) due to the sheet material. A practical consideration is the fact that more subcutaneous fat tissue and skin are being pulled forward leading to folds in the nipple area. On balance, improvement to the current design is required before implementation in screening practice can be considered. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Carraro do Nascimento, Vinicius; Bourke, Anita G
2018-02-01
More than half of the patients with an impalpable malignant breast lesion have a mammographically detected and imaged-guided localisation, which can be technically challenging for the breast surgeon. Specimen imaging is used to confirm successful excision of the localised index lesion and has improved the operating list efficiency resulting in a higher number of excisions per surgical list. The aim of this study was to evaluate whether introducing IDSM (intra-operative digital specimen mammography) saved operation time for localised breast surgery. A single-centre retrospective review was undertaken to compare the operation time (from incision to wound closure) taken for excision of 114 consecutive image-guided localised impalpable breast lesions, performed using departmental specimen radiography (DSR), 6 months prior to the introduction of IDSM (Hologic, Trident ® ) in March 2013, with the theatre time taken for excision of 121 consecutive image-guided localised impalpable breast lesions in the 6 months following introduction of IDSM. There was no significant difference in mean surgical time, which were 47.8 (±27.3) minutes in the CSR group and 48.8 (±25.7) minutes in the IDSM group. We were expecting to confirm a reduction in theatre time with the introduction of IDSM. Surprisingly, no difference in operating times was demonstrated. Factors that influenced the impact of IDSM included the proximity of the imaging department to the operating theatre. © 2017 The Royal Australian and New Zealand College of Radiologists.
Intraoperative Evaluation of Breast Tumor Margins with Optical Coherence Tomography
Nguyen, Freddy T.; Zysk, Adam M.; Chaney, Eric J.; Kotynek, Jan G.; Oliphant, Uretz J.; Bellafiore, Frank J.; Rowland, Kendrith M.; Johnson, Patricia A.; Boppart, Stephen A.
2009-01-01
As breast cancer screening rates increase, smaller and more numerous lesions are being identified earlier, leading to more breast-conserving surgical procedures. Achieving a clean surgical margin represents a technical challenge with important clinical implications. Optical coherence tomography (OCT) is introduced as an intraoperative high-resolution imaging technique that assesses surgical breast tumor margins by providing real-time microscopic images up to 2 mm beneath the tissue surface. In a study of 37 patients split between training and study groups, OCT images covering 1 cm2 regions were acquired from surgical margins of lumpectomy specimens, registered with ink, and correlated with corresponding histological sections. A 17 patient training set used to establish standard imaging protocols and OCT evaluation criteria demonstrated that areas of higher scattering tissue with a heterogeneous pattern were indicative of tumor cells and tumor tissue, in contrast to lower scattering adipocytes found in normal breast tissue. The remaining 20 patients were enrolled into the feasibility study. Of these lumpectomy specimens, 11 were identified with a positive or close surgical margin and 9 were identified with a negative margin under OCT. Based on histological findings, 9 true positives, 9 true negatives, 2 false positives, and 0 false negatives were found, yielding a sensitivity of 100% and specificity of 82%. These results demonstrate the potential of OCT as a real-time method for intraoperative margin assessment in breast conserving surgeries. PMID:19910294
Digital X-Ray Imager Final Report CRADA No. TSB-1161-95
DOE Office of Scientific and Technical Information (OSTI.GOV)
Logan, C.; Toker, E.
The global objective of this cooperation was to lower the cost and improve the quality of breast health care in the United States. We planned to achieve it by designing a very high performance digital radiography unit for breast surgical specimen radiography in the operating room. These technical goals needed to be achieved at reasonable manufacturing costs to enable MedOptics to achieve high market penetration at a profit.
Branderhorst, Woutjan; de Groot, Jerry E; van Lier, Monique G J T B; Highnam, Ralph P; den Heeten, Gerard J; Grimbergen, Cornelis A
2017-08-01
To assess the accuracy of two methods of determining the contact area between the compression paddle and the breast in mammography. An accurate method to determine the contact area is essential to accurately calculate the average compression pressure applied by the paddle. For a set of 300 breast compressions, we measured the contact areas between breast and paddle, both capacitively using a transparent foil with indium-tin-oxide (ITO) coating attached to the paddle, and retrospectively from the obtained mammograms using image processing software (Volpara Enterprise, algorithm version 1.5.2). A gold standard was obtained from video images of the compressed breast. During each compression, the breast was illuminated from the sides in order to create a dark shadow on the video image where the breast was in contact with the compression paddle. We manually segmented the shadows captured at the time of x-ray exposure and measured their areas. We found a strong correlation between the manual segmentations and the capacitive measurements [r = 0.989, 95% CI (0.987, 0.992)] and between the manual segmentations and the image processing software [r = 0.978, 95% CI (0.972, 0.982)]. Bland-Altman analysis showed a bias of -0.0038 dm 2 for the capacitive measurement (SD 0.0658, 95% limits of agreement [-0.1329, 0.1252]) and -0.0035 dm 2 for the image processing software [SD 0.0962, 95% limits of agreement (-0.1921, 0.1850)]. The size of the contact area between the paddle and the breast can be determined accurately and precisely, both in real-time using the capacitive method, and retrospectively using image processing software. This result is beneficial for scientific research, data analysis and quality control systems that depend on one of these two methods for determining the average pressure on the breast during mammographic compression. © 2017 Sigmascreening B.V. Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Acaba, K. J. C.; Cinco, L. D.; Melchor, J. N.
2016-03-01
Daily QC tests performed on screen film mammography (SFM) equipment are essential to ensure that both SFM unit and film processor are working in a consistent manner. The Breast Imaging Unit of USTH-Benavides Cancer Institute has been conducting QC following the test protocols in the IAEA Human Health Series No.2 manual. However, the availability of Leeds breast phantom (CRP E13039) in the facility made the task easier. Instead of carrying out separate tests on AEC constancy and light sensitometry, only one exposure of the phantom is done to accomplish the two tests. It was observed that measurements made on mAs output and optical densities (ODs) using the Leeds TOR (MAX) phantom are comparable with that obtained from the usual conduct of tests, taking into account the attenuation characteristic of the phantom. Image quality parameters such as low contrast and high contrast details were also evaluated from the phantom image. The authors recognize the usefulness of the phantom in determining technical factors that will help improve detection of smallest pathological details on breast images. The phantom is also convenient for daily QC monitoring and economical since less number of films is expended.
2013-01-01
Background Magnetic resonance imaging (MRI) guided wire localization presents several challenges apart from the technical difficulties. An alternative to this conventional localization method using a wire is the radio-guided occult lesion localization (ROLL), more related to safe surgical margins and reductions in excision volume. The purpose of this study was to establish a safe and reliable magnetic resonance imaging-radioguided occult lesion localization (MRI-ROLL) technique and to report our initial experience with the localization of nonpalpable breast lesions only observed on MRI. Methods Sixteen women (mean age 53.2 years) with 17 occult breast lesions underwent radio-guided localization in a 1.5-T MR system using a grid-localizing system. All patients had a diagnostic MRI performed prior to the procedure. An intralesional injection of Technetium-99m macro-aggregated albumin followed by distilled water was performed. After the procedure, scintigraphy was obtained. Surgical resection was performed with the help of a gamma detector probe. The lesion histopathology and imaging concordance; the procedure’s positive predictive value (PPV), duration time, complications, and accuracy; and the rate of exactly excised lesions evaluated with MRI six months after the surgery were assessed. Results One lesion in one patient had to be excluded because the radioactive substance came back after the injection, requiring a wire placement. Of the remaining cases, there were four malignant lesions, nine benign lesions, and three high-risk lesions. Surgical histopathology and imaging findings were considered concordant in all benign and high-risk cases. The PPV of MRI-ROLL was greater if the indication for the initial MR examination was active breast cancer. The median procedure duration time was 26 minutes, and all included procedures were defined as accurate. The exact and complete lesion removal was confirmed in all (100%) patients who underwent six-month postoperative MRI (50%). Conclusions MRI-ROLL offers a precise, technically feasible, safe, and rapid means for performing preoperative MRI localizations in the breast. PMID:24044428
[Breast tomosynthesis: a new tool for diagnosing breast cancer].
Martínez Miravete, P; Etxano, J
2015-01-01
Breast cancer continues to be the most common malignant tumor in women in occidental countries. Mammography is currently the technique of choice for screening programs; however, although it has been widely validated, mammography has its limitations, especially in dense breasts. Breast tomosynthesis is a revolutionary advance in the diagnosis of breast cancer. It makes it possible to define lesions that are occult in the glandular tissue and therefore to detect breast tumors that are impossible to see on conventional mammograms. In considering the combined use of mammography and tomosynthesis, many factors must be taken into account apart from cancer detection; these include additional radiation, the recall rate, and the time necessary to carry out and interpret the two tests. In this article, we review the technical principles of tomosynthesis, it main uses, and the future perspective for this imaging technique. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.
D3D augmented reality imaging system: proof of concept in mammography.
Douglas, David B; Petricoin, Emanuel F; Liotta, Lance; Wilson, Eugene
2016-01-01
The purpose of this article is to present images from simulated breast microcalcifications and assess the pattern of the microcalcifications with a technical development called "depth 3-dimensional (D3D) augmented reality". A computer, head display unit, joystick, D3D augmented reality software, and an in-house script of simulated data of breast microcalcifications in a ductal distribution were used. No patient data was used and no statistical analysis was performed. The D3D augmented reality system demonstrated stereoscopic depth perception by presenting a unique image to each eye, focal point convergence, head position tracking, 3D cursor, and joystick fly-through. The D3D augmented reality imaging system offers image viewing with depth perception and focal point convergence. The D3D augmented reality system should be tested to determine its utility in clinical practice.
WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Karellas, A.
Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detectionmore » more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.« less
[The breast of the adolescent girl].
Bruant-Rodier, C; Dissaux, C; Baratte, A; Francois Fiquet, C; Bodin, F
2016-10-01
During adolescence, psychological and physical changes occur and breast takes a major place in the young woman body image. Except rare malign tumors, breast pathologies at this age are mainly benign or malformative. Malformative issues are revealed during breast growth, as isolated asymmetry or associated to other regional anomalies, with abnormal shape or volume of the breast, or even supernumerary breast. Therapeutic solutions will not differ from the ones used for adults. Breast lipofilling, recently admitted by plastic surgery community is an interesting tool that can be used on young women. Choosing the right technic depends on the initial problem. It comes at an early stage to offset hypoplasia resulting in a problem of asymmetry. It waits for breast stability in case of hypertrophy and for legal majority in case of breast augmentation using implants. Psychological impairment stays however a central issue and forces the surgeon to adapt to the individual and to his body change over time. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
WE-FG-207A-01: Introduction to Dedicated Breast CT - Early Studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vedantham, S.
Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detectionmore » more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.« less
WE-FG-207A-04: Performance Characteristics of Photon-Counting Breast CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kalender, W.
Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detectionmore » more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.« less
WE-FG-207A-02: Why We Need Breast CT? - Clinical Perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
O’Connell, A.
Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detectionmore » more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.« less
WE-FG-207A-00: Advances in Dedicated Breast CT
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detectionmore » more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.« less
WE-FG-207A-03: Low-Dose Cone-Beam Breast CT: Physics and Technology Development
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boone, J.
Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detectionmore » more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively investigating dedicated breast CT. The development of large-area flat-panel detectors with field-of-view sufficient to image the entire breast in each projection enabled development of flat-panel cone-beam breast CT. More recently, the availability of complimentary metal-oxide semiconductor (CMOS) detectors with lower system noise and finer pixel pitch, combined with the development of x-ray tubes with focal spot dimensions similar to mammography systems, has shown improved spatial resolution and could improve visualization of microcalcifications. These technological developments promise clinical translation of low-dose cone-beam breast CT. Dedicated photon-counting breast CT (pcBCT) systems represent a novel detector design, which provide high spatial resolution (∼ 100µm) and low mean glandular dose (MGD). The CdTe-based direct conversion detector technology was previously evaluated and confirmed by simulations and basic experiments on laboratory setups [Kalender et al., Eur Radiol 22: 1–8, 2012]. Measurements of dose, technical image quality parameters, and surgical specimens on a pcBCT scanner have been completed. Comparative evaluation of surgical specimens showed that pcBCT outperformed mammography and digital breast tomosynthesis with respect to 3D spatial resolution, detectability of calcifications, and soft tissue delineation. Major barriers to widespread clinical use of BCT relate to radiation dose, imaging of microcalcifications, and adequate coverage of breast tissue near the chest wall. Adequate chest wall coverage is also technically challenging but recent progress in x-ray tube, detector and table design now enables full breast coverage in the majority of patients. At this time, BCT has been deemed to be suitable for diagnostic imaging but not yet for screening. The mean glandular dose (MGD) from BCT has been reported to be between 5.7 to 27.8 mGy, and this range is comparable to, and within the range of, the MGD of 2.6 to 31.6 mGy in diagnostic mammography. In diagnostic studies, the median MGD from BCT and mammography were 12.6 and 11.1 mGy, respectively [Vedantham et al., Phys Med Biol. 58: 7921–36, 2013]. Moreover, in diagnostic imaging of the breast the location of the lesion is known and therefore characterization and not detection is by far the primary consideration. The role of bCT is particularly compelling for diagnostic imaging of the breast because it may replace in part the multiple mammographic views of the breast under vigorous compression. Other non-screening potential applications of bCT include the assessment of response to neoadjuvant therapy [Vedantham et al., J Clin Imaging Sci 4, 64, 2014] and pre-surgical evaluation. Learning Objectives: To understand the metrics used to evaluate screening and diagnostic imaging To understand the benefits and limitations of current clinical modalities To understand how breast CT can improve over current clinical modalities To note the early attempts to translate breast CT to the clinic in 1970s-1990s To understand the recent developments in low-dose cone-beam breast CT To understand the recent developments in photon-counting breast CT To understand the radiation dose, clinical translation, and recent developments in diagnostic imaging with breast CT Supported in part by NIH grants R21 CA134128, R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH or the NCI.; S. Vedantham, Funding sources: Supported in part by NIH/NCI grants R01 CA128906 and R01 CA195512. The contents are solely the responsibility of the authors and do not reflect the official views of the NIH/NCI. Disclosures: Research collaboration with Koning Corporation, West Henrietta, NY. Conflicts of Interest: J. Boone, This research was supported in part by NIH grant R01CA181081; W. Kalender, WK is founder and CEO of CT Imaging GmbH Erlangen, Germany.; A. Karellas, NIH R21 CA134128, R01 CA128906, and R01 CA195512 and Research collaboration with Koning Corporation.« less
Advances in imaging technologies for planning breast reconstruction
Mohan, Anita T.
2016-01-01
The role and choice of preoperative imaging for planning in breast reconstruction is still a disputed topic in the reconstructive community, with varying opinion on the necessity, the ideal imaging modality, costs and impact on patient outcomes. Since the advent of perforator flaps their use in microsurgical breast reconstruction has grown. Perforator based flaps afford lower donor morbidity by sparing the underlying muscle provide durable results, superior cosmesis to create a natural looking new breast, and are preferred in the context of radiation therapy. However these surgeries are complex; more technically challenging that implant based reconstruction, and leaves little room for error. The role of imaging in breast reconstruction can assist the surgeon in exploring or confirming flap choices based on donor site characteristics and presence of suitable perforators. Vascular anatomical studies in the lab have provided the surgeon a foundation of knowledge on location and vascular territories of individual perforators to improve our understanding for flap design and safe flap harvest. The creation of a presurgical map in patients can highlight any abnormal or individual anatomical variance to optimize flap design, intraoperative decision-making and execution of flap harvest with greater predictability and efficiency. This article highlights the role and techniques for preoperative planning using the newer technologies that have been adopted in reconstructive clinical practice: computed tomographic angiography (CTA), magnetic resonance angiography (MRA), laser-assisted indocyanine green fluorescence angiography (LA-ICGFA) and dynamic infrared thermography (DIRT). The primary focus of this paper is on the application of CTA and MRA imaging modalities. PMID:27047790
Brice, Matthew E; Gossweiler, Marisa; Bennett, Larry
2017-03-01
Artifacts are universal across all imaging modalities, varying in their conspicuity and significance. In this report three patients with pathology-proven breast cancer who had densities masquerading as microcalcifications at the resection margins of the lumpectomy specimens, but had negative microscopic margins, will be discussed. It was determined that these pseudocalcifications were the result of ink precipitates from a commonly utilized tissue marking dye. This artifact was further evaluated and reproduced by utilizing a boneless chicken breast as a phantom. © RSNA, 2016.
Paterson, Carolyn L; Hendry, Fraser R; Bolster, Alison A
2018-06-01
Successful localization of nodes in breast cancer patients depends upon the effectiveness of the lymphoscintigraphy technique employed. A benefit of performing imaging as part of this procedure is that it allows sites to audit their technique. An audit of breast cancer patients at the Glasgow Royal Infirmary (GRI) hospital showed nodes to be visualized in only 81% of patients. Current guidelines state that nodes should be seen in more than 95% of patients. A period of investigation and review led to changes being made to the injection and imaging technique employed at the GRI site. Following these changes a re-audit was performed that showed that the node visualization rate has successfully been increased to 97%, thereby meeting the standards set in the guidelines. This technical note details the results of the initial audit and re-audit, and explains the investigation and changes made to clinical procedures at the GRI site to improve the node visualization rate. The challenges that can occur when performing breast sentinel node procedures are also discussed.
A Standard Mammography Unit - Standard 3D Ultrasound Probe Fusion Prototype: First Results.
Schulz-Wendtland, Rüdiger; Jud, Sebastian M; Fasching, Peter A; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W; Emons, Julius
2017-06-01
The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound - the second important imaging modality in complementary breast diagnostics - without increasing examination time or requiring additional staff.
Schulz-Wendtland, Rüdiger; Jud, Sebastian M.; Fasching, Peter A.; Hartmann, Arndt; Radicke, Marcus; Rauh, Claudia; Uder, Michael; Wunderle, Marius; Gass, Paul; Langemann, Hanna; Beckmann, Matthias W.; Emons, Julius
2017-01-01
Aim The combination of different imaging modalities through the use of fusion devices promises significant diagnostic improvement for breast pathology. The aim of this study was to evaluate image quality and clinical feasibility of a prototype fusion device (fusion prototype) constructed from a standard tomosynthesis mammography unit and a standard 3D ultrasound probe using a new method of breast compression. Materials and Methods Imaging was performed on 5 mastectomy specimens from patients with confirmed DCIS or invasive carcinoma (BI-RADS ™ 6). For the preclinical fusion prototype an ABVS system ultrasound probe from an Acuson S2000 was integrated into a MAMMOMAT Inspiration (both Siemens Healthcare Ltd) and, with the aid of a newly developed compression plate, digital mammogram and automated 3D ultrasound images were obtained. Results The quality of digital mammogram images produced by the fusion prototype was comparable to those produced using conventional compression. The newly developed compression plate did not influence the applied x-ray dose. The method was not more labour intensive or time-consuming than conventional mammography. From the technical perspective, fusion of the two modalities was achievable. Conclusion In this study, using only a few mastectomy specimens, the fusion of an automated 3D ultrasound machine with a standard mammography unit delivered images of comparable quality to conventional mammography. The device allows simultaneous ultrasound – the second important imaging modality in complementary breast diagnostics – without increasing examination time or requiring additional staff. PMID:28713173
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruschin, Mark, E-mail: Mark.Ruschin@sunnybrook.ca; Chin, Lee; Ravi, Ananth
Purpose: To develop a multipurpose gel-based breast phantom consisting of a simulated tumor with realistic imaging properties in CT, ultrasound and MRI, or a postsurgical cavity on CT. Applications for the phantom include: deformable image registration (DIR) quality assurance (QA), autosegmentation validation, and localization testing and training for minimally invasive image-guided procedures such as those involving catheter or needle insertion. Methods: A thermoplastic mask of a typical breast patient lying supine was generated and then filled to make an array of phantoms. The background simulated breast tissue consisted of 32.4 g each of ballistic gelatin (BG) powder and Metamusil™ (MM)more » dissolved in 800 ml of water. Simulated tumors were added using the following recipe: 12 g of barium sulfate (1.4% v/v) plus 0.000 14 g copper sulfate plus 0.7 g of MM plus 7.2 g of BG all dissolved in 75 ml of water. The phantom was evaluated quantitatively in CT by comparing Hounsfield units (HUs) with actual breast tissue. For ultrasound and MRI, the phantoms were assessed based on subjective image quality and signal-difference to noise (SDNR) ratio, respectively. The stiffness of the phantom was evaluated based on ultrasound elastography measurements to yield an average Young’s modulus. In addition, subjective tactile assessment of phantom was performed under needle insertion. Results: The simulated breast tissue had a mean background value of 24 HU on CT imaging, which more closely resembles fibroglandular tissue (40 HU) as opposed to adipose (−100 HU). The tumor had a mean CT number of 45 HU, which yielded a qualitatively realistic image contrast relative to the background either as an intact tumor or postsurgical cavity. The tumor appeared qualitatively realistic on ultrasound images, exhibiting hypoechoic characteristics compared to background. On MRI, the tumor exhibited a SDNR of 3.7. The average Young’s modulus was computed to be 15.8 ± 0.7 kPa (1 SD). Conclusions: We have developed a process to efficiently and inexpensively produce multipurpose breast phantoms containing simulated tumors visible on CT, ultrasound, and MRI. The phantoms have been evaluated for image quality and elasticity and can serve as a medium for DIR QA, autosegmentation QA, and training for minimally invasive procedures.« less
O'Connor, Michael K; Morrow, Melissa M; Tran, Thuy; Hruska, Carrie B; Conners, Amy L; Hunt, Katie N
2017-02-01
The purpose of this study was to perform a pilot evaluation of an integrated molecular breast imaging/ultrasound (MBI/US) system designed to enable, in real-time, the registration of US to MBI and diagnostic evaluation of breast lesions detected on MBI. The MBI/US system was constructed by modifying an existing dual-head cadmium zinc telluride (CZT)-based MBI gamma camera. The upper MBI detector head was replaced with a mesh panel, which allowed an ultrasound probe to access the breast. An optical tracking system was used to monitor the location of the ultrasound transducer, referenced to the MBI detector. The lesion depth at which ultrasound was targeted was estimated from analysis of previously acquired dual-head MBI datasets. A software tool was developed to project the US field of view onto the current MBI image. Correlation of lesion location between both modalities with real-time MBI/US scanning was confirmed in a breast phantom model and assessed in 12 patients with a breast lesion detected on MBI. Combined MBI/US scanning allowed for registration of lesions detected on US and MBI as validated in phantom experiments. In patient studies, successful registration was achieved in 8 of 12 (67%) patients, with complete registration achieved in seven and partial registration achieved in one patient. In 4 of 12 (37%) patients, lesion registration was not achieved, partially attributed to uncertainty in lesion depth estimates from MBI. The MBI/US system enabled successful registration of US to MBI in over half of patients studied in this pilot evaluation. Future studies are needed to determine if real-time, registered US imaging of MBI-detected lesions may obviate the need to proceed to more expensive procedures such as contrast-enhanced breast MRI for diagnostic workup or biopsy of MBI findings. © 2016 American Association of Physicists in Medicine.
Pusic, Andrea L; Klassen, Anne F; Snell, Laura; Cano, Stefan J; McCarthy, Colleen; Scott, Amie; Cemal, Yeliz; Rubin, Lisa R; Cordeiro, Peter G
2014-01-01
The goal of postmastectomy breast reconstruction is to restore a woman’s body image and to satisfy her personal expectations regarding the results of surgery. Studies in other surgical areas have shown that unrecognized or unfulfilled expectations may predict dissatisfaction more strongly than even the technical success of the surgery. Patient expectations play an especially critical role in elective procedures, such as cancer reconstruction, where the patient’s primary motivation is improved health-related quality of life. In breast reconstruction, assessment of patient expectations is therefore vital to optimal patient care. This report summarizes the existing literature on patient expectations regarding breast reconstruction, and provides a viewpoint on how this field can evolve. Specifically, we consider how systematic measurement and management of patient expectations may improve patient education, shared medical decision-making and patient perception of outcomes. PMID:22458616
Chae, Michael P.; Hunter-Smith, David J.
2015-01-01
Background The high incidence of breast cancer and growing number of breast cancer patients undergoing mastectomy has led to breast reconstruction becoming an important part of holistic treatment for these patients. In planning autologous reconstructions, preoperative assessment of donor site microvascular anatomy with advanced imaging modalities has assisted in the appropriate selection of flap donor site, individual perforators, and lead to an overall improvement in flap outcomes. In this review, we compare the accuracy of fluorescent angiography, computed tomographic angiography (CTA), and magnetic resonance angiography (MRA) and their impact on clinical outcomes. Methods A review of the published English literature dating from 1950 to 2015 using databases, such as PubMed, Medline, Web of Science, and EMBASE was undertaken. Results Fluorescent angiography is technically limited by its inability to evaluate deep-lying perforators and hence, it has a minimal role in the preoperative setting. However, it may be useful intraoperatively in evaluating microvascular anastomotic patency and the mastectomy skin perfusion. CTA is currently widely considered the standard, due to its high accuracy and reliability. Multiple studies have demonstrated its ability to improve clinical outcomes, such as operative length and flap complications. However, concerns surrounding exposure to radiation and nephrotoxic contrast agents exist. MRA has been explored, however despite recent advances, the image quality of MRA is considered inferior to CTA. Conclusions Preoperative imaging is an essential component in planning autologous breast reconstruction. Fluorescent angiography presents minimal role as a preoperative imaging modality, but may be a useful intraoperative adjunct to assess the anastomosis and the mastectomy skin perfusion. Currently, CTA is the gold standard preoperatively. MRA has a role, particularly for women of younger age, iodine allergy, and renal impairment. PMID:26005648
Contrast-enhanced spectral mammography in patients with MRI contraindications.
Richter, Vivien; Hatterman, Valerie; Preibsch, Heike; Bahrs, Sonja D; Hahn, Markus; Nikolaou, Konstantin; Wiesinger, Benjamin
2017-01-01
Background Contrast-enhanced spectral mammography (CESM) is a novel breast imaging technique providing comparable diagnostic accuracy to breast magnetic resonance imaging (MRI). Purpose To show that CESM in patients with MRI contraindications is feasible, accurate, and useful as a problem-solving tool, and to highlight its limitations. Material and Methods A total of 118 patients with MRI contraindications were examined by CESM. Histology was obtained in 94 lesions and used as gold standard for diagnostic accuracy calculations. Imaging data were reviewed retrospectively for feasibility, accuracy, and technical problems. The diagnostic yield of CESM as a problem-solving tool and for therapy response evaluation was reviewed separately. Results CESM was more accurate than mammography (MG) for lesion categorization (r = 0.731, P < 0.0001 vs. r = 0.279, P = 0.006) and for lesion size estimation (r = 0.738 vs. r = 0.689, P < 0.0001). Negative predictive value of CESM was significantly higher than of MG (85.71% vs. 30.77%, P < 0.0001). When used for problem-solving, CESM changed patient management in 2/8 (25%) cases. Superposition artifacts and timing problems affected diagnostic utility in 3/118 (2.5%) patients. Conclusion CESM is a feasible and accurate alternative for patients with MRI contraindications, but it is necessary to be aware of the method's technical limitations.
Ma, Wang Kei; Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter
2017-03-01
Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ 2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ 2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring.
Borgen, Rita; Kelly, Judith; Millington, Sara; Hilton, Beverley; Aspin, Rob; Lança, Carla; Hogg, Peter
2017-01-01
Objective: Blurred images in full-field digital mammography are a problem in the UK Breast Screening Programme. Technical recalls may be due to blurring not being seen on lower resolution monitors used for review. This study assesses the visual detection of blurring on a 2.3-MP monitor and a 5-MP report grade monitor and proposes an observer standard for the visual detection of blurring on a 5-MP reporting grade monitor. Methods: 28 observers assessed 120 images for blurring; 20 images had no blurring present, whereas 100 images had blurring imposed through mathematical simulation at 0.2, 0.4, 0.6, 0.8 and 1.0 mm levels of motion. Technical recall rate for both monitors and angular size at each level of motion were calculated. χ2 tests were used to test whether significant differences in blurring detection existed between 2.3- and 5-MP monitors. Results: The technical recall rate for 2.3- and 5-MP monitors are 20.3% and 9.1%, respectively. The angular size for 0.2- to 1-mm motion varied from 55 to 275 arc s. The minimum amount of motion for visual detection of blurring in this study is 0.4 mm. For 0.2-mm simulated motion, there was no significant difference [χ2 (1, N = 1095) = 1.61, p = 0.20] in blurring detection between the 2.3- and 5-MP monitors. Conclusion: According to this study, monitors ≤2.3 MP are not suitable for technical review of full-field digital mammography images for the detection of blur. Advances in knowledge: This research proposes the first observer standard for the visual detection of blurring. PMID:28134567
Computing the scatter component of mammographic images.
Highnam, R P; Brady, J M; Shepstone, B J
1994-01-01
The authors build upon a technical report (Tech. Report OUEL 2009/93, Engng. Sci., Oxford Uni., Oxford, UK, 1993) in which they proposed a model of the mammographic imaging process for which scattered radiation is a key degrading factor. Here, the authors propose a way of estimating the scatter component of the signal at any pixel within a mammographic image, and they use this estimate for model-based image enhancement. The first step is to extend the authors' previous model to divide breast tissue into "interesting" (fibrous/glandular/cancerous) tissue and fat. The scatter model is then based on the idea that the amount of scattered radiation reaching a point is related to the energy imparted to the surrounding neighbourhood. This complex relationship is approximated using published empirical data, and it varies with the size of the breast being imaged. The approximation is further complicated by needing to take account of extra-focal radiation and breast edge effects. The approximation takes the form of a weighting mask which is convolved with the total signal (primary and scatter) to give a value which is input to a "scatter function", approximated using three reference cases, and which returns a scatter estimate. Given a scatter estimate, the more important primary component can be calculated and used to create an image recognizable by a radiologist. The images resulting from this process are clearly enhanced, and model verification tests based on an estimate of the thickness of interesting tissue present proved to be very successful. A good scatter model opens the was for further processing to remove the effects of other degrading factors, such as beam hardening.
A hybrid deep learning approach to predict malignancy of breast lesions using mammograms
NASA Astrophysics Data System (ADS)
Wang, Yunzhi; Heidari, Morteza; Mirniaharikandehei, Seyedehnafiseh; Gong, Jing; Qian, Wei; Qiu, Yuchen; Zheng, Bin
2018-03-01
Applying deep learning technology to medical imaging informatics field has been recently attracting extensive research interest. However, the limited medical image dataset size often reduces performance and robustness of the deep learning based computer-aided detection and/or diagnosis (CAD) schemes. In attempt to address this technical challenge, this study aims to develop and evaluate a new hybrid deep learning based CAD approach to predict likelihood of a breast lesion detected on mammogram being malignant. In this approach, a deep Convolutional Neural Network (CNN) was firstly pre-trained using the ImageNet dataset and serve as a feature extractor. A pseudo-color Region of Interest (ROI) method was used to generate ROIs with RGB channels from the mammographic images as the input to the pre-trained deep network. The transferred CNN features from different layers of the CNN were then obtained and a linear support vector machine (SVM) was trained for the prediction task. By applying to a dataset involving 301 suspicious breast lesions and using a leave-one-case-out validation method, the areas under the ROC curves (AUC) = 0.762 and 0.792 using the traditional CAD scheme and the proposed deep learning based CAD scheme, respectively. An ensemble classifier that combines the classification scores generated by the two schemes yielded an improved AUC value of 0.813. The study results demonstrated feasibility and potentially improved performance of applying a new hybrid deep learning approach to develop CAD scheme using a relatively small dataset of medical images.
Chi, Chongwei; Ye, Jinzuo; Ding, Haolong; He, De; Huang, Wenhe; Zhang, Guo-Jun; Tian, Jie
2013-01-01
Assessment of the sentinel lymph node (SLN) in patients with early stage breast cancer is vital in selecting the appropriate surgical approach. However, the existing methods, including methylene blue and nuclides, possess low efficiency and effectiveness in mapping SLNs, and to a certain extent exert side effects during application. Indocyanine green (ICG), as a fluorescent dye, has been proved reliable usage in SLN detection by several other groups. In this paper, we introduce a novel surgical navigation system to detect SLN with ICG. This system contains two charge-coupled devices (CCD) to simultaneously capture real-time color and fluorescent video images through two different bands. During surgery, surgeons only need to follow the fluorescence display. In addition, the system saves data automatically during surgery enabling surgeons to find the registration point easily according to image recognition algorithms. To test our system, 5 mice and 10 rabbits were used for the preclinical setting and 22 breast cancer patients were utilized for the clinical evaluation in our experiments. The detection rate was 100% and an average of 2.7 SLNs was found in 22 patients. Our results show that the usage of our surgical navigation system with ICG to detect SLNs in breast cancer patients is technically feasible. PMID:24358319
Gandhi, Diksha; Crotty, Dominic J; Stevens, Grant M; Schmidt, Taly Gilat
2015-11-01
This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%-20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.
Conners, Amy Lynn; Jones, Katie N; Hruska, Carrie B; Geske, Jennifer R; Boughey, Judy C; Rhodes, Deborah J
2015-09-01
The purposes of this study were to compare the tumor appearance of invasive breast cancer on direct-conversion molecular breast imaging using a standardized lexicon and to determine how often direct-conversion molecular breast imaging identifies all known invasive tumor foci in the breast, and whether this differs for invasive ductal versus lobular histologic profiles. Patients with prior invasive breast cancer and concurrent direct-conversion molecular breast imaging examinations were retrospectively reviewed. Blinded review of direct-conversion molecular breast imaging examinations was performed by one of two radiologists, according to a validated lexicon. Direct-conversion molecular breast imaging findings were matched with lesions described on the pathology report to exclude benign reasons for direct-conversion molecular breast imaging findings and to document direct-conversion molecular breast imaging-occult tumor foci. Associations between direct-conversion molecular breast imaging findings and tumor histologic profiles were examined using chi-square tests. In 286 patients, 390 invasive tumor foci were present in 294 breasts. A corresponding direct-conversion molecular breast imaging finding was present for 341 of 390 (87%) tumor foci described on the pathology report. Invasive ductal carcinoma (IDC) tumor foci were more likely to be a mass (40% IDC vs 15% invasive lobular carcinoma [ILC]; p < 0.001) and to have marked intensity than were ILC foci (63% IDC vs 32% ILC; p < 0.001). Direct-conversion molecular breast imaging correctly revealed all pathology-proven foci of invasive disease in 79.8% of cases and was more likely to do so for IDC than for ILC (86.1% vs 56.7%; p < 0.0001). Overall, direct-conversion molecular breast imaging showed all known invasive foci in 249 of 286 (87%) patients. Direct-conversion molecular breast imaging features of invasive cancer, including lesion type and intensity, differ by histologic subtype. Direct-conversion molecular breast imaging is less likely to show all foci of ILC compared with IDC.
Detecting breast microcalcifications using super-resolution ultrasound imaging: a clinical study
NASA Astrophysics Data System (ADS)
Huang, Lianjie; Labyed, Yassin; Hanson, Kenneth; Sandoval, Daniel; Pohl, Jennifer; Williamson, Michael
2013-03-01
Imaging breast microcalcifications is crucial for early detection and diagnosis of breast cancer. It is challenging for current clinical ultrasound to image breast microcalcifications. However, new imaging techniques using data acquired with a synthetic-aperture ultrasound system have the potential to significantly improve ultrasound imaging. We recently developed a super-resolution ultrasound imaging method termed the phase-coherent multiple-signal classification (PC-MUSIC). This signal subspace method accounts for the phase response of transducer elements to improve image resolution. In this paper, we investigate the clinical feasibility of our super-resolution ultrasound imaging method for detecting breast microcalcifications. We use our custom-built, real-time synthetic-aperture ultrasound system to acquire breast ultrasound data for 40 patients whose mammograms show the presence of breast microcalcifications. We apply our super-resolution ultrasound imaging method to the patient data, and produce clear images of breast calcifications. Our super-resolution ultrasound PC-MUSIC imaging with synthetic-aperture ultrasound data can provide a new imaging modality for detecting breast microcalcifications in clinic without using ionizing radiation.
Krecsák, László; Micsik, Tamás; Kiszler, Gábor; Krenács, Tibor; Szabó, Dániel; Jónás, Viktor; Császár, Gergely; Czuni, László; Gurzó, Péter; Ficsor, Levente; Molnár, Béla
2011-01-18
The immunohistochemical detection of estrogen (ER) and progesterone (PR) receptors in breast cancer is routinely used for prognostic and predictive testing. Whole slide digitalization supported by dedicated software tools allows quantization of the image objects (e.g. cell membrane, nuclei) and an unbiased analysis of immunostaining results. Validation studies of image analysis applications for the detection of ER and PR in breast cancer specimens provided strong concordance between the pathologist's manual assessment of slides and scoring performed using different software applications. The effectiveness of two connected semi-automated image analysis software (NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14) for determination of ER and PR status in formalin-fixed paraffin embedded breast cancer specimens immunostained with the automated Leica Bond Max system was studied. First the detection algorithm was calibrated to the scores provided an independent assessors (pathologist), using selected areas from 38 small digital slides (created from 16 cases) containing a mean number of 195 cells. Each cell was manually marked and scored according to the Allred-system combining frequency and intensity scores. The performance of the calibrated algorithm was tested on 16 cases (14 invasive ductal carcinoma, 2 invasive lobular carcinoma) against the pathologist's manual scoring of digital slides. The detection was calibrated to 87 percent object detection agreement and almost perfect Total Score agreement (Cohen's kappa 0.859, quadratic weighted kappa 0.986) from slight or moderate agreement at the start of the study, using the un-calibrated algorithm. The performance of the application was tested against the pathologist's manual scoring of digital slides on 53 regions of interest of 16 ER and PR slides covering all positivity ranges, and the quadratic weighted kappa provided almost perfect agreement (κ = 0.981) among the two scoring schemes. NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14 software application proved to be a reliable image analysis tool for pathologists testing ER and PR status in breast cancer.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Batumalai, Vikneswary, E-mail: vikneswary.batumalai@sswahs.nsw.gov.au; South Western Clinical School, University of New South Wales, Sydney, New South Wales; Quinn, Alexandra
Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). Themore » mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account.« less
Wojcinski, Sebastian; Brandhorst, Kathrin; Sadigh, Gelareh; Hillemanns, Peter; Degenhardt, Friedrich
2013-01-01
Acoustic radiation force impulse imaging (ARFI) with Virtual Touch™ tissue quantification (VTTQ) enables the determination of shear wave velocity (SWV) in meters per second (m/s). The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign) and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s) (P < 0.001). Focusing on breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s"). Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s) (P < 0.001). The best diagnostic accuracy (75.9%) was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved.
Biomechanical modelling for breast image registration
NASA Astrophysics Data System (ADS)
Lee, Angela; Rajagopal, Vijay; Chung, Jae-Hoon; Bier, Peter; Nielsen, Poul M. F.; Nash, Martyn P.
2008-03-01
Breast cancer is a leading cause of death in women. Tumours are usually detected by palpation or X-ray mammography followed by further imaging, such as magnetic resonance imaging (MRI) or ultrasound. The aim of this research is to develop a biophysically-based computational tool that will allow accurate collocation of features (such as suspicious lesions) across multiple imaging views and modalities in order to improve clinicians' diagnosis of breast cancer. We have developed a computational framework for generating individual-specific, 3D finite element models of the breast. MR images were obtained of the breast under gravity loading and neutrally buoyant conditions. Neutrally buoyant breast images, obtained whilst immersing the breast in water, were used to estimate the unloaded geometry of the breast (for present purposes, we have assumed that the densities of water and breast tissue are equal). These images were segmented to isolate the breast tissues, and a tricubic Hermite finite element mesh was fitted to the digitised data points in order to produce a customized breast model. The model was deformed, in accordance with finite deformation elasticity theory, to predict the gravity loaded state of the breast in the prone position. The unloaded breast images were embedded into the reference model and warped based on the predicted deformation. In order to analyse the accuracy of the model predictions, the cross-correlation image comparison metric was used to compare the warped, resampled images with the clinical images of the prone gravity loaded state. We believe that a biomechanical image registration tool of this kind will aid radiologists to provide more reliable diagnosis and localisation of breast cancer.
Breast ultrasound tomography with two parallel transducer arrays
NASA Astrophysics Data System (ADS)
Huang, Lianjie; Shin, Junseob; Chen, Ting; Lin, Youzuo; Gao, Kai; Intrator, Miranda; Hanson, Kenneth
2016-03-01
Breast ultrasound tomography is an emerging imaging modality to reconstruct the sound speed, density, and ultrasound attenuation of the breast in addition to ultrasound reflection/beamforming images for breast cancer detection and characterization. We recently designed and manufactured a new synthetic-aperture breast ultrasound tomography prototype with two parallel transducer arrays consisting of a total of 768 transducer elements. The transducer arrays are translated vertically to scan the breast in a warm water tank from the chest wall/axillary region to the nipple region to acquire ultrasound transmission and reflection data for whole-breast ultrasound tomography imaging. The distance of these two ultrasound transducer arrays is adjustable for scanning breasts with different sizes. We use our breast ultrasound tomography prototype to acquire phantom and in vivo patient ultrasound data to study its feasibility for breast imaging. We apply our recently developed ultrasound imaging and tomography algorithms to ultrasound data acquired using our breast ultrasound tomography system. Our in vivo patient imaging results demonstrate that our breast ultrasound tomography can detect breast lesions shown on clinical ultrasound and mammographic images.
Hutchinson, J Ciaran; Shelmerdine, Susan C; Simcock, Ian C; Sebire, Neil J; Arthurs, Owen J
2017-07-01
Microfocus CT (micro-CT) has traditionally been used in industry and preclinical studies, although it may find new applicability in the routine clinical setting. It can provide high-resolution three-dimensional digital imaging data sets to the same level of detail as microscopic examination without the need for tissue dissection. Micro-CT is already enabling non-invasive detailed internal assessment of various tissue specimens, particularly in breast imaging and early gestational fetal autopsy, not previously possible from more conventional modalities such as MRI or CT. In this review, we discuss the technical aspects behind micro-CT image acquisition, how early work with small animal studies have informed our knowledge of human disease and the imaging performed so far on human tissue specimens. We conclude with potential future clinical applications of this novel and emerging technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gandhi, Diksha; Schmidt, Taly Gilat, E-mail: taly.gilat-schmidt@marquette.edu; Crotty, Dominic J.
Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings.more » Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.« less
Online advertising by three commercial breast imaging services: message takeout and effectiveness.
Johnson, Rebecca; Jalleh, Geoffrey; Pratt, Iain S; Donovan, Robert J; Lin, Chad; Saunders, Christobel; Slevin, Terry
2013-10-01
Mammography is widely acknowledged to be the most cost-effective technique for population screening for breast cancer. Recently in Australia, imaging modalities other than mammography, including thermography, electrical impedance, and computerised breast imaging, have been increasingly promoted as alternative methods of breast cancer screening. This study assessed the impact of three commercial breast imaging companies' promotional material upon consumers' beliefs about the effectiveness of the companies' technology in detecting breast cancer, and consumers' intentions to seek more information or consider having their breasts imaged by these modalities. Results showed 90% of respondents agreed that the companies' promotional material promoted the message that the advertised breast imaging method was effective in detecting breast cancer, and 80% agreed that the material promoted the message that the imaging method was equally or more effective than a mammogram. These findings have implications for women's preference for and uptake of alternative breast imaging services over mammography. Copyright © 2013 Elsevier Ltd. All rights reserved.
Teo, Irene; Reece, Gregory P; Huang, Sheng-Cheng; Mahajan, Kanika; Andon, Johnny; Khanal, Pujjal; Sun, Clement; Nicklaus, Krista; Merchant, Fatima; Markey, Mia K; Fingeret, Michelle Cororve
2018-03-01
Reconstruction as part of treatment for breast cancer is aimed at mitigating body image concerns after mastectomy. Although algorithms have been developed to objectively assess breast reconstruction outcomes, associations between objectively quantified breast aesthetic appearance and patient-reported body image outcomes have not been examined. Further, the role of appearance investment in explaining a patient's body image is not well understood. We investigated the extent to which objectively quantified breast symmetry and patient-reported appearance investment were associated with body image dissatisfaction in patients undergoing cancer-related breast reconstruction. Breast cancer patients in different stages of reconstruction (n = 190) completed self-report measures of appearance investment and body image dissatisfaction. Vertical extent and horizontal extent symmetry values, which are indicators of breast symmetry, were calculated from clinical photographs. Associations among breast symmetry, appearance investment, body image dissatisfaction, and patient clinical factors were examined. Multi-variable regression was used to evaluate the extent to which symmetry and appearance investment were associated with body image dissatisfaction. Vertical extent symmetry, but not horizontal extent symmetry, was associated with body image dissatisfaction. Decreased vertical extent symmetry (β = -.19, P < .05) and increased appearance investment (β = .45, P < .001) were significantly associated with greater body image dissatisfaction while controlling for clinical factors. Breast symmetry and patient appearance investment both significantly contribute to an understanding of patient-reported body image satisfaction during breast reconstruction treatment. Copyright © 2017 John Wiley & Sons, Ltd.
Correlation of breast image alignment using biomechanical modelling
NASA Astrophysics Data System (ADS)
Lee, Angela; Rajagopal, Vijay; Bier, Peter; Nielsen, Poul M. F.; Nash, Martyn P.
2009-02-01
Breast cancer is one of the most common causes of cancer death among women around the world. Researchers have found that a combination of imaging modalities (such as x-ray mammography, magnetic resonance, and ultrasound) leads to more effective diagnosis and management of breast cancers because each imaging modality displays different information about the breast tissues. In order to aid clinicians in interpreting the breast images from different modalities, we have developed a computational framework for generating individual-specific, 3D, finite element (FE) models of the breast. Medical images are embedded into this model, which is subsequently used to simulate the large deformations that the breasts undergo during different imaging procedures, thus warping the medical images to the deformed views of the breast in the different modalities. In this way, medical images of the breast taken in different geometric configurations (compression, gravity, etc.) can be aligned according to physically feasible transformations. In order to analyse the accuracy of the biomechanical model predictions, squared normalised cross correlation (NCC2) was used to provide both local and global comparisons of the model-warped images with clinical images of the breast subject to different gravity loaded states. The local comparison results were helpful in indicating the areas for improvement in the biomechanical model. To improve the modelling accuracy, we will need to investigate the incorporation of breast tissue heterogeneity into the model and altering the boundary conditions for the breast model. A biomechanical image registration tool of this kind will help radiologists to provide more reliable diagnosis and localisation of breast cancer.
Objective breast tissue image classification using Quantitative Transmission ultrasound tomography
NASA Astrophysics Data System (ADS)
Malik, Bilal; Klock, John; Wiskin, James; Lenox, Mark
2016-12-01
Quantitative Transmission Ultrasound (QT) is a powerful and emerging imaging paradigm which has the potential to perform true three-dimensional image reconstruction of biological tissue. Breast imaging is an important application of QT and allows non-invasive, non-ionizing imaging of whole breasts in vivo. Here, we report the first demonstration of breast tissue image classification in QT imaging. We systematically assess the ability of the QT images’ features to differentiate between normal breast tissue types. The three QT features were used in Support Vector Machines (SVM) classifiers, and classification of breast tissue as either skin, fat, glands, ducts or connective tissue was demonstrated with an overall accuracy of greater than 90%. Finally, the classifier was validated on whole breast image volumes to provide a color-coded breast tissue volume. This study serves as a first step towards a computer-aided detection/diagnosis platform for QT.
Visualization of microcalcifications using photoacoustic imaging: feasibility study
NASA Astrophysics Data System (ADS)
Hsiao, Tsai-Chu; Wang, Po-Hsun; Fan, Chih-Tai; Cheng, Yao-You; Li, Meng-Lin
2011-03-01
Recently, photoacoustic imaging has been intensively studied for blood vessel imaging, and shown its capability of revealing vascular features suggestive of malignancy of breast cancer. In this study, we explore the feasibility of visualization of micro-calcifications using photoacoustic imaging. Breast micro-calcification is also known as one of the most important indicators for early breast cancer detection. The non-ionizing radiation and speckle free nature of photoacoustic imaging overcomes the drawbacks of current diagnostic tools - X-ray mammography and ultrasound imaging, respectively. We employed a 10-MHz photoacoustic imaging system to verify our idea. A sliced chicken breast phantom with granulated calcium hydroxyapatite (HA) - major chemical composition of the breast calcification associated with malignant breast cancers - embedded was imaged. With the near infared (NIR) laser excitation, it is shown that the distribution of ~500 μm HAs can be clearly imaged. In addition, photoacoustic signals from HAs rivals those of blood given an optimal NIR wavelength. In summary, photoacoustic imaging shows its promise for breast micro-calcification detection. Moreover, fusion of the photoacoustic and ultrasound images can reveal the location and distribution of micro-calcifications within anatomical landmarks of the breast tissue, which is clinically useful for biopsy and diagnosis of breast cancer staging.
Comparison of breast percent density estimation from raw versus processed digital mammograms
NASA Astrophysics Data System (ADS)
Li, Diane; Gavenonis, Sara; Conant, Emily; Kontos, Despina
2011-03-01
We compared breast percent density (PD%) measures obtained from raw and post-processed digital mammographic (DM) images. Bilateral raw and post-processed medio-lateral oblique (MLO) images from 81 screening studies were retrospectively analyzed. Image acquisition was performed with a GE Healthcare DS full-field DM system. Image post-processing was performed using the PremiumViewTM algorithm (GE Healthcare). Area-based breast PD% was estimated by a radiologist using a semi-automated image thresholding technique (Cumulus, Univ. Toronto). Comparison of breast PD% between raw and post-processed DM images was performed using the Pearson correlation (r), linear regression, and Student's t-test. Intra-reader variability was assessed with a repeat read on the same data-set. Our results show that breast PD% measurements from raw and post-processed DM images have a high correlation (r=0.98, R2=0.95, p<0.001). Paired t-test comparison of breast PD% between the raw and the post-processed images showed a statistically significant difference equal to 1.2% (p = 0.006). Our results suggest that the relatively small magnitude of the absolute difference in PD% between raw and post-processed DM images is unlikely to be clinically significant in breast cancer risk stratification. Therefore, it may be feasible to use post-processed DM images for breast PD% estimation in clinical settings. Since most breast imaging clinics routinely use and store only the post-processed DM images, breast PD% estimation from post-processed data may accelerate the integration of breast density in breast cancer risk assessment models used in clinical practice.
Heacock, Laura; Gao, Yiming; Heller, Samantha L; Melsaether, Amy N; Babb, James S; Block, Tobias K; Otazo, Ricardo; Kim, Sungheon G; Moy, Linda
2017-06-01
To compare a novel multicoil compressed sensing technique with flexible temporal resolution, golden-angle radial sparse parallel (GRASP), to conventional fat-suppressed spoiled three-dimensional (3D) gradient-echo (volumetric interpolated breath-hold examination, VIBE) MRI in evaluating the conspicuity of benign and malignant breast lesions. Between March and August 2015, 121 women (24-84 years; mean, 49.7 years) with 180 biopsy-proven benign and malignant lesions were imaged consecutively at 3.0 Tesla in a dynamic contrast-enhanced (DCE) MRI exam using sagittal T1-weighted fat-suppressed 3D VIBE in this Health Insurance Portability and Accountability Act-compliant, retrospective study. Subjects underwent MRI-guided breast biopsy (mean, 13 days [1-95 days]) using GRASP DCE-MRI, a fat-suppressed radial "stack-of-stars" 3D FLASH sequence with golden-angle ordering. Three readers independently evaluated breast lesions on both sequences. Statistical analysis included mixed models with generalized estimating equations, kappa-weighted coefficients and Fisher's exact test. All lesions demonstrated good conspicuity on VIBE and GRASP sequences (4.28 ± 0.81 versus 3.65 ± 1.22), with no significant difference in lesion detection (P = 0.248). VIBE had slightly higher lesion conspicuity than GRASP for all lesions, with VIBE 12.6% (0.63/5.0) more conspicuous (P < 0.001). Masses and nonmass enhancement (NME) were more conspicuous on VIBE (P < 0.001), with a larger difference for NME (14.2% versus 9.4% more conspicuous). Malignant lesions were more conspicuous than benign lesions (P < 0.001) on both sequences. GRASP DCE-MRI, a multicoil compressed sensing technique with high spatial resolution and flexible temporal resolution, has near-comparable performance to conventional VIBE imaging for breast lesion evaluation. 3 Technical Efficacy: Stage 3 J. MAGN. RESON. IMAGING 2017;45:1746-1752. © 2016 International Society for Magnetic Resonance in Medicine.
Technical Note: Robust measurement of the slice-sensitivity profile in breast tomosynthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maki, Aili K., E-mail: aili.maki@sri.utoronto.ca
2016-08-15
Purpose: The purpose of this work is to improve the repeatability of the measurement of the slice-sensitivity profile (SSP) in reconstructed breast tomosynthesis volumes. Methods: A grid of aluminum ball-bearings (BBs) within a PMMA phantom was imaged on breast tomosynthesis systems from three different manufacturers. The full-width half-maximum (FWHM) values were measured for the SSPs of the BBs in the reconstructed volumes. The effect of transforming the volumes from a Cartesian coordinate system (CCS) to a cone-beam coordinate system (CBCS) on the variability in the FWHM values was assessed. Results: Transforming the volumes from a CCS to a CBCS beforemore » measuring the SSPs reduced the coefficient of variation (COV) in the measurements of FWHM in repeated measurements by 56% and reduced the dependence of the FWHM values on the location of the BBs within the reconstructed volume by 76%. Conclusions: Measuring the SSP in the volumes in a CBCS improves the robustness of the measurement.« less
Digital information management: a progress report on the National Digital Mammography Archive
NASA Astrophysics Data System (ADS)
Beckerman, Barbara G.; Schnall, Mitchell D.
2002-05-01
Digital mammography creates very large images, which require new approaches to storage, retrieval, management, and security. The National Digital Mammography Archive (NDMA) project, funded by the National Library of Medicine (NLM), is developing a limited testbed that demonstrates the feasibility of a national breast imaging archive, with access to prior exams; patient information; computer aids for image processing, teaching, and testing tools; and security components to ensure confidentiality of patient information. There will be significant benefits to patients and clinicians in terms of accessible data with which to make a diagnosis and to researchers performing studies on breast cancer. Mammography was chosen for the project, because standards were already available for digital images, report formats, and structures. New standards have been created for communications protocols between devices, front- end portal and archive. NDMA is a distributed computing concept that provides for sharing and access across corporate entities. Privacy, auditing, and patient consent are all integrated into the system. Five sites, Universities of Pennsylvania, Chicago, North Carolina and Toronto, and BWXT Y12, are connected through high-speed networks to demonstrate functionality. We will review progress, including technical challenges, innovative research and development activities, standards and protocols being implemented, and potential benefits to healthcare systems.
Automated 3D ultrasound elastography of the breast: a phantom validation study
NASA Astrophysics Data System (ADS)
Hendriks, Gijs A. G. M.; Holländer, Branislav; Menssen, Jan; Milkowski, Andy; Hansen, Hendrik H. G.; de Korte, Chris L.
2016-04-01
In breast cancer screening, the automated breast volume scanner (ABVS) was introduced as an alternative for mammography since the latter technique is less suitable for women with dense breasts. Although clinical studies show promising results, clinicians report two disadvantages: long acquisition times (>90 s) introducing breathing artefacts, and high recall rates due to detection of many small lesions of uncertain malignant potential. Technical improvements for faster image acquisition and better discrimination between benign and malignant lesions are thus required. Therefore, the aim of this study was to investigate if 3D ultrasound elastography using plane-wave imaging is feasible. Strain images of a breast elastography phantom were acquired by an ABVS-mimicking device that allowed axial and elevational movement of the attached transducer. Pre- and post-deformation volumes were acquired with different constant speeds (between 1.25 and 40.0 mm s-1) and by three protocols: Go-Go (pre- and post-volumes with identical start and end positions), Go-Return (similar to Go-Go with opposite scanning directions) and Control (pre- and post-volumes acquired per position, this protocol can be seen as reference). Afterwards, 2D and 3D cross-correlation and strain algorithms were applied to the acquired volumes and the results were compared. The Go-Go protocol was shown to be superior with better strain image quality (CNRe and SNRe) than Go-Return and to be similar as Control. This can be attributed to applying opposite mechanical forces to the phantom during the Go-Return protocol, leading to out-of-plane motion. This motion was partly compensated by using 3D cross-correlation. However, the quality was still inferior to Go-Go. Since these results were obtained in a phantom study with controlled deformations, the effect of possible uncontrolled in vivo tissue motion artefacts has to be addressed in future studies. In conclusion, it seems feasible to implement 3D ultrasound quasi-static elastography on an ABVS-like system and to reduce scan times within one breath-hold (~10 s) by plane-wave acquisitions.
Li, Zhiwei; Ai, Tao; Hu, Yiqi; Yan, Xu; Nickel, Marcel Dominik; Xu, Xiao; Xia, Liming
2018-01-01
To investigate the application of whole-lesion histogram analysis of pharmacokinetic parameters for differentiating malignant from benign breast lesions on dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). In all, 92 women with 97 breast lesions (26 benign and 71 malignant lesions) were enrolled in this study. Patients underwent dynamic breast MRI at 3T using a prototypical CAIPIRINHA-Dixon-TWIST-VIBE (CDT-VIBE) sequence and a subsequent surgery or biopsy. Inflow rate of the agent between plasma and interstitium (K trans ), outflow rate of agent between interstitium and plasma (K ep ), extravascular space volume per unit volume of tissue (v e ) including mean value, 25th/50th/75th/90th percentiles, skewness, and kurtosis were then calculated based on the whole lesion. A single-sample Kolmogorov-Smirnov test, paired t-test, and receiver operating characteristic curve (ROC) analysis were used for statistical analysis. Malignant breast lesions had significantly higher K trans , K ep , and lower v e in mean values, 25th/50th/75th/90th percentiles, and significantly higher skewness of v e than benign breast lesions (all P < 0.05). There was no significant difference in kurtosis values between malignant and benign breast lesions (all P > 0.05). The 90th percentile of K trans , the 90th percentile of K ep , and the 50th percentile of v e showed the greatest areas under the ROC curve (AUC) for each pharmacokinetic parameter derived from DCE-MRI. The 90th percentile of K ep achieved the highest AUC value (0.927) among all histogram-derived values. The whole-lesion histogram analysis of pharmacokinetic parameters can improve the diagnostic accuracy of breast DCE-MRI with the CDT-VIBE technique. The 90th percentile of K ep may be the best indicator in differentiation between malignant and benign breast lesions. 4 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2018;47:91-96. © 2017 International Society for Magnetic Resonance in Medicine.
Imaging of common breast implants and implant-related complications: A pictorial essay
Shah, Amisha T; Jankharia, Bijal B
2016-01-01
The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer. PMID:27413269
Imaging of common breast implants and implant-related complications: A pictorial essay.
Shah, Amisha T; Jankharia, Bijal B
2016-01-01
The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.
Ultrashort Microwave-Pumped Real-Time Thermoacoustic Breast Tumor Imaging System.
Ye, Fanghao; Ji, Zhong; Ding, Wenzheng; Lou, Cunguang; Yang, Sihua; Xing, Da
2016-03-01
We report the design of a real-time thermoacoustic (TA) scanner dedicated to imaging deep breast tumors and investigate its imaging performance. The TA imaging system is composed of an ultrashort microwave pulse generator and a ring transducer array with 384 elements. By vertically scanning the transducer array that encircles the breast phantom, we achieve real-time, 3D thermoacoustic imaging (TAI) with an imaging speed of 16.7 frames per second. The stability of the microwave energy and its distribution in the cling-skin acoustic coupling cup are measured. The results indicate that there is a nearly uniform electromagnetic field in each XY-imaging plane. Three plastic tubes filled with salt water are imaged dynamically to evaluate the real-time performance of our system, followed by 3D imaging of an excised breast tumor embedded in a breast phantom. Finally, to demonstrate the potential for clinical applications, the excised breast of a ewe embedded with an ex vivo human breast tumor is imaged clearly with a contrast of about 1:2.8. The high imaging speed, large field of view, and 3D imaging performance of our dedicated TAI system provide the potential for clinical routine breast screening.
Santos, Jonathan; Chaudhari, Abhijit J; Joshi, Anand A; Ferrero, Andrea; Yang, Kai; Boone, John M; Badawi, Ramsey D
2014-09-01
Dedicated breast CT and PET/CT scanners provide detailed 3D anatomical and functional imaging data sets and are currently being investigated for applications in breast cancer management such as diagnosis, monitoring response to therapy and radiation therapy planning. Our objective was to evaluate the performance of the diffeomorphic demons (DD) non-rigid image registration method to spatially align 3D serial (pre- and post-contrast) dedicated breast computed tomography (CT), and longitudinally-acquired dedicated 3D breast CT and positron emission tomography (PET)/CT images. The algorithmic parameters of the DD method were optimized for the alignment of dedicated breast CT images using training data and fixed. The performance of the method for image alignment was quantitatively evaluated using three separate data sets; (1) serial breast CT pre- and post-contrast images of 20 women, (2) breast CT images of 20 women acquired before and after repositioning the subject on the scanner, and (3) dedicated breast PET/CT images of 7 women undergoing neo-adjuvant chemotherapy acquired pre-treatment and after 1 cycle of therapy. The DD registration method outperformed no registration (p < 0.001) and conventional affine registration (p ≤ 0.002) for serial and longitudinal breast CT and PET/CT image alignment. In spite of the large size of the imaging data, the computational cost of the DD method was found to be reasonable (3-5 min). Co-registration of dedicated breast CT and PET/CT images can be performed rapidly and reliably using the DD method. This is the first study evaluating the DD registration method for the alignment of dedicated breast CT and PET/CT images. Copyright © 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Tucker, F. Lee
2012-01-01
Modern breast imaging, including magnetic resonance imaging, provides an increasingly clear depiction of breast cancer extent, often with suboptimal pathologic confirmation. Pathologic findings guide management decisions, and small increments in reported tumor characteristics may rationalize significant changes in therapy and staging. Pathologic techniques to grossly examine resected breast tissue have changed little during this era of improved breast imaging and still rely primarily on the techniques of gross inspection and specimen palpation. Only limited imaging information is typically conveyed to pathologists, typically in the form of wire-localization images from breast-conserving procedures. Conventional techniques of specimen dissection and section submission destroy the three-dimensional integrity of the breast anatomy and tumor distribution. These traditional methods of breast specimen examination impose unnecessary limitations on correlation with imaging studies, measurement of cancer extent, multifocality, and margin distance. Improvements in pathologic diagnosis, reporting, and correlation of breast cancer characteristics can be achieved by integrating breast imagers into the specimen examination process and the use of large-format sections which preserve local anatomy. This paper describes the successful creation of a large-format pathology program to routinely serve all patients in a busy interdisciplinary breast center associated with a community-based nonprofit health system in the United States. PMID:23316372
Delineating Extramammary Findings at Breast MR Imaging.
Gao, Yiming; Ibidapo, Opeyemi; Toth, Hildegard K; Moy, Linda
2017-01-01
Breast magnetic resonance (MR) imaging is the only breast imaging modality that consistently encompasses extramammary structures in the thorax and upper abdomen. Incidental extramammary findings on breast MR images of patients with a history of breast cancer or other malignancies are significantly more likely to be malignant and may affect staging and treatment. An understanding of the frequency, distribution, and context of extramammary findings on breast MR images and a familiarity with common and uncommon sites of breast cancer metastasis inform the differential diagnosis and prompt the appropriate diagnostic next step, to differentiate benign from malignant findings. High-yield organ systems on breast MR images, as reflected by a high positive predictive value for malignancy, are correlated with known distant sites of breast cancer metastasis in the bone, lung, liver, and lymph nodes. Staging is considered when disease involves the skin and chest wall. Unusual sites of breast cancer metastasis from invasive lobular carcinoma are discussed, including the gastrointestinal tract, peritoneum, and adrenal glands. Nonmalignant clinically important findings involving the cardiovascular and gastrointestinal systems are reviewed, and potential pitfalls in diagnosis and interpretation are highlighted. A consistently systematic diagnostic approach is emphasized for identifying extramammary abnormalities on breast MR images. All things considered, the radiologist should be able to improve diagnostic sensitivity and specificity while interpreting extramammary findings on breast MR images. © RSNA, 2017.
NASA Astrophysics Data System (ADS)
Han, Tao; Chen, Lingyun; Lai, Chao-Jen; Liu, Xinming; Shen, Youtao; Zhong, Yuncheng; Ge, Shuaiping; Yi, Ying; Wang, Tianpeng; Shaw, Chris C.
2009-02-01
Images of mastectomy breast specimens have been acquired with a bench top experimental Cone beam CT (CBCT) system. The resulting images have been segmented to model an uncompressed breast for simulation of various CBCT techniques. To further simulate conventional or tomosynthesis mammographic imaging for comparison with the CBCT technique, a deformation technique was developed to convert the CT data for an uncompressed breast to a compressed breast without altering the breast volume or regional breast density. With this technique, 3D breast deformation is separated into two 2D deformations in coronal and axial views. To preserve the total breast volume and regional tissue composition, each 2D deformation step was achieved by altering the square pixels into rectangular ones with the pixel areas unchanged and resampling with the original square pixels using bilinear interpolation. The compression was modeled by first stretching the breast in the superior-inferior direction in the coronal view. The image data were first deformed by distorting the voxels with a uniform distortion ratio. These deformed data were then deformed again using distortion ratios varying with the breast thickness and re-sampled. The deformation procedures were applied in the axial view to stretch the breast in the chest wall to nipple direction while shrinking it in the mediolateral to lateral direction re-sampled and converted into data for uniform cubic voxels. Threshold segmentation was applied to the final deformed image data to obtain the 3D compressed breast model. Our results show that the original segmented CBCT image data were successfully converted into those for a compressed breast with the same volume and regional density preserved. Using this compressed breast model, conventional and tomosynthesis mammograms were simulated for comparison with CBCT.
Atallah, Vincent; Escarmant, Patrick; Vinh‐Hung, Vincent
2016-01-01
Monitoring and controlling respiratory motion is a challenge for the accuracy and safety of therapeutic irradiation of thoracic tumors. Various commercial systems based on the monitoring of internal or external surrogates have been developed but remain costly. In this article we describe and validate Madibreast, an in‐house‐made respiratory monitoring and processing device based on optical tracking of external markers. We designed an optical apparatus to ensure real‐time submillimetric image resolution at 4 m. Using OpenCv libraries, we optically tracked high‐contrast markers set on patients' breasts. Validation of spatial and time accuracy was performed on a mechanical phantom and on human breast. Madibreast was able to track motion of markers up to a 5 cm/s speed, at a frame rate of 30 fps, with submillimetric accuracy on mechanical phantom and human breasts. Latency was below 100 ms. Concomitant monitoring of three different locations on the breast showed discrepancies in axial motion up to 4 mm for deep‐breathing patterns. This low‐cost, computer‐vision system for real‐time motion monitoring of the irradiation of breast cancer patients showed submillimetric accuracy and acceptable latency. It allowed the authors to highlight differences in surface motion that may be correlated to tumor motion. PACS number(s): 87.55.km PMID:27685116
Leduc, Nicolas; Atallah, Vincent; Escarmant, Patrick; Vinh-Hung, Vincent
2016-09-08
Monitoring and controlling respiratory motion is a challenge for the accuracy and safety of therapeutic irradiation of thoracic tumors. Various commercial systems based on the monitoring of internal or external surrogates have been developed but remain costly. In this article we describe and validate Madibreast, an in-house-made respiratory monitoring and processing device based on optical tracking of external markers. We designed an optical apparatus to ensure real-time submillimetric image resolution at 4 m. Using OpenCv libraries, we optically tracked high-contrast markers set on patients' breasts. Validation of spatial and time accuracy was performed on a mechanical phantom and on human breast. Madibreast was able to track motion of markers up to a 5 cm/s speed, at a frame rate of 30 fps, with submillimetric accuracy on mechanical phantom and human breasts. Latency was below 100 ms. Concomitant monitoring of three different locations on the breast showed discrepancies in axial motion up to 4 mm for deep-breathing patterns. This low-cost, computer-vision system for real-time motion monitoring of the irradiation of breast cancer patients showed submillimetric accuracy and acceptable latency. It allowed the authors to highlight differences in surface motion that may be correlated to tumor motion.v. © 2016 The Authors.
BREAST: a novel method to improve the diagnostic efficacy of mammography
NASA Astrophysics Data System (ADS)
Brennan, P. C.; Tapia, K.; Ryan, J.; Lee, W.
2013-03-01
High quality breast imaging and accurate image assessment are critical to the early diagnoses, treatment and management of women with breast cancer. Breast Screen Reader Assessment Strategy (BREAST) provides a platform, accessible by researchers and clinicians world-wide, which will contain image data bases, algorithms to assess reader performance and on-line systems for image evaluation. The platform will contribute to the diagnostic efficacy of breast imaging in Australia and beyond on two fronts: reducing errors in mammography, and transforming our assessment of novel technologies and techniques. Mammography is the primary diagnostic tool for detecting breast cancer with over 800,000 women X-rayed each year in Australia, however, it fails to detect 30% of breast cancers with a number of missed cancers being visible on the image [1-6]. BREAST will monitor the mistakes, identify reasons for mammographic errors, and facilitate innovative solutions to reduce error rates. The BREAST platform has the potential to enable expert assessment of breast imaging innovations, anywhere in the world where experts or innovations are located. Currently, innovations are often being assessed by limited numbers of individuals who happen to be geographically located close to the innovation, resulting in equivocal studies with low statistical power. BREAST will transform this current paradigm by enabling large numbers of experts to assess any new method or technology using our embedded evaluation methods. We are confident that this world-first system will play an important part in the future efficacy of breast imaging.
Breast imaging with the SoftVue imaging system: first results
NASA Astrophysics Data System (ADS)
Duric, Neb; Littrup, Peter; Schmidt, Steven; Li, Cuiping; Roy, Olivier; Bey-Knight, Lisa; Janer, Roman; Kunz, Dave; Chen, Xiaoyang; Goll, Jeffrey; Wallen, Andrea; Zafar, Fouzaan; Allada, Veerendra; West, Erik; Jovanovic, Ivana; Li, Kuo; Greenway, William
2013-03-01
For women with dense breast tissue, who are at much higher risk for developing breast cancer, the performance of mammography is at its worst. Consequently, many early cancers go undetected when they are the most treatable. Improved cancer detection for women with dense breasts would decrease the proportion of breast cancers diagnosed at later stages, which would significantly lower the mortality rate. The emergence of whole breast ultrasound provides good performance for women with dense breast tissue, and may eliminate the current trade-off between the cost effectiveness of mammography and the imaging performance of more expensive systems such as magnetic resonance imaging. We report on the performance of SoftVue, a whole breast ultrasound imaging system, based on the principles of ultrasound tomography. SoftVue was developed by Delphinus Medical Technologies and builds on an early prototype developed at the Karmanos Cancer Institute. We present results from preliminary testing of the SoftVue system, performed both in the lab and in the clinic. These tests aimed to validate the expected improvements in image performance. Initial qualitative analyses showed major improvements in image quality, thereby validating the new imaging system design. Specifically, SoftVue's imaging performance was consistent across all breast density categories and had much better resolution and contrast. The implications of these results for clinical breast imaging are discussed and future work is described.
Comparison of volumetric breast density estimations from mammography and thorax CT
NASA Astrophysics Data System (ADS)
Geeraert, N.; Klausz, R.; Cockmartin, L.; Muller, S.; Bosmans, H.; Bloch, I.
2014-08-01
Breast density has become an important issue in current breast cancer screening, both as a recognized risk factor for breast cancer and by decreasing screening efficiency by the masking effect. Different qualitative and quantitative methods have been proposed to evaluate area-based breast density and volumetric breast density (VBD). We propose a validation method comparing the computation of VBD obtained from digital mammographic images (VBDMX) with the computation of VBD from thorax CT images (VBDCT). We computed VBDMX by applying a conversion function to the pixel values in the mammographic images, based on models determined from images of breast equivalent material. VBDCT is computed from the average Hounsfield Unit (HU) over the manually delineated breast volume in the CT images. This average HU is then compared to the HU of adipose and fibroglandular tissues from patient images. The VBDMX method was applied to 663 mammographic patient images taken on two Siemens Inspiration (hospL) and one GE Senographe Essential (hospJ). For the comparison study, we collected images from patients who had a thorax CT and a mammography screening exam within the same year. In total, thorax CT images corresponding to 40 breasts (hospL) and 47 breasts (hospJ) were retrieved. Averaged over the 663 mammographic images the median VBDMX was 14.7% . The density distribution and the inverse correlation between VBDMX and breast thickness were found as expected. The average difference between VBDMX and VBDCT is smaller for hospJ (4%) than for hospL (10%). This study shows the possibility to compare VBDMX with the VBD from thorax CT exams, without additional examinations. In spite of the limitations caused by poorly defined breast limits, the calibration of mammographic images to local VBD provides opportunities for further quantitative evaluations.
NASA Astrophysics Data System (ADS)
Thiery, Gwendoline; Mernaugh, Ray L.; Yan, Heping; Spraggins, Jeffrey M.; Yang, Junhai; Parl, Fritz F.; Caprioli, Richard M.
2012-10-01
Recombinant scfv antibodies specific for CYP1A1 and CYP1B1 P450 enzymes were combined with targeted imaging mass spectrometry to simultaneously detect the P450 enzymes present in archived, paraffin-embedded, human breast cancer tissue sections. By using CYP1A1 and CYP1B1 specific scfv, each coupled to a unique reporter molecule (i.e., a mass tag) it was possible to simultaneously detect multiple antigens within a single tissue sample with high sensitivity and specificity using mass spectrometry. The capability of imaging multiple antigens at the same time is a significant advance that overcomes technical barriers encountered when using present day approaches to develop assays that can simultaneously detect more than a single antigen in the same tissue sample.
Breast cancer screening controversies: who, when, why, and how?
Chetlen, Alison; Mack, Julie; Chan, Tiffany
2016-01-01
Mammographic screening is effective in reducing mortality from breast cancer. The issue is not whether mammography is effective, but whether the false positive rate and false negative rates can be reduced. This review will discuss controversies including the reduction in breast cancer mortality, overdiagnosis, the ideal screening candidate, and the optimal imaging modality for breast cancer screening. The article will compare and contrast screening mammography, tomosynthesis, whole-breast screening ultrasound, magnetic resonance imaging, and molecular breast imaging. Though supplemental imaging modalities are being utilized to improve breast cancer diagnosis, mammography still remains the gold standard for breast cancer screening. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Lou, Yang
Photoacoustic computed tomography(PACT), also known as optoacoustic tomography (OAT), is an emerging imaging technique that has developed rapidly in recent years. The combination of the high optical contrast and the high acoustic resolution of this hybrid imaging technique makes it a promising candidate for human breast imaging, where conventional imaging techniques including X-ray mammography, B-mode ultrasound, and MRI suffer from low contrast, low specificity for certain breast types, and additional risks related to ionizing radiation. Though significant works have been done to push the frontier of PACT breast imaging, it is still challenging to successfully build a PACT breast imaging system and apply it to wide clinical use because of various practical reasons. First, computer simulation studies are often conducted to guide imaging system designs, but the numerical phantoms employed in most previous works consist of simple geometries and do not reflect the true anatomical structures within the breast. Therefore the effectiveness of such simulation-guided PACT system in clinical experiments will be compromised. Second, it is challenging to design a system to simultaneously illuminate the entire breast with limited laser power. Some heuristic designs have been proposed where the illumination is non-stationary during the imaging procedure, but the impact of employing such a design has not been carefully studied. Third, current PACT imaging systems are often optimized with respect to physical measures such as resolution or signal-to-noise ratio (SNR). It would be desirable to establish an assessing framework where the detectability of breast tumor can be directly quantified, therefore the images produced by such optimized imaging systems are not only visually appealing, but most informative in terms of the tumor detection task. Fourth, when imaging a large three-dimensional (3D) object such as the breast, iterative reconstruction algorithms are often utilized to alleviate the need to collect densely sampled measurement data hence a long scanning time. However, the heavy computation burden associated with iterative algorithms largely hinders its application in PACT breast imaging. This dissertation is dedicated to address these aforementioned problems in PACT breast imaging. A method that generates anatomically realistic numerical breast phantoms is first proposed to facilitate computer simulation studies in PACT. The non-stationary illumination designs for PACT breast imaging are then systematically investigated in terms of its impact on reconstructed images. We then apply signal detection theory to assess different system designs to demonstrate how an objective, task-based measure can be established for PACT breast imaging. To address the slow computation time of iterative algorithms for PACT imaging, we propose an acceleration method that employs an approximated but much faster adjoint operator during iterations, which can reduce the computation time by a factor of six without significantly compromising image quality. Finally, some clinical results are presented to demonstrate that the PACT breast imaging can resolve most major and fine vascular structures within the breast, along with some pathological biomarkers that may indicate tumor development.
Chen, Jia-Mei; Li, Yan; Xu, Jun; Gong, Lei; Wang, Lin-Wei; Liu, Wen-Lou; Liu, Juan
2017-03-01
With the advance of digital pathology, image analysis has begun to show its advantages in information analysis of hematoxylin and eosin histopathology images. Generally, histological features in hematoxylin and eosin images are measured to evaluate tumor grade and prognosis for breast cancer. This review summarized recent works in image analysis of hematoxylin and eosin histopathology images for breast cancer prognosis. First, prognostic factors for breast cancer based on hematoxylin and eosin histopathology images were summarized. Then, usual procedures of image analysis for breast cancer prognosis were systematically reviewed, including image acquisition, image preprocessing, image detection and segmentation, and feature extraction. Finally, the prognostic value of image features and image feature-based prognostic models was evaluated. Moreover, we discussed the issues of current analysis, and some directions for future research.
Radiologic and histopathologic review of rare benign and malignant breast diseases
Dağıstan, Emine; Kızıldağ, Betül; Gürel, Safiye; Barut, Yüksel; Paşaoğlu, Esra
2017-01-01
High social awareness of breast diseases and the rise in breast imaging facilities have led to an increase in the detection of even rare benign and malignant breast lesions. Breast lesions are associated with a broad spectrum of imaging characteristics, and each radiologic imaging technique reflects different characteristics of them. We aimed to increase familiarity of the radiologist with these uncommon lesions as well as correlate histopathologic findings with the radiologic imaging features of the tumors. Histopathologic examination is necessary in the evaluation of such breast lesions, particularly when radiologic images are not definitive for a specific diagnosis. PMID:28508760
Bychkovsky, Brittany L; Lin, Nancy U
2017-02-01
Imaging in the evaluation and follow-up of patients with early or advanced breast cancer is an important aspect of cancer care. The role of imaging in breast cancer depends on the goal and should only be performed to guide clinical decisions. Imaging is valuable if a finding will change the course of treatment and improve outcomes, whether this is disease-free survival, overall survival or quality-of-life. In the last decade, imaging is often overused in oncology and contributes to rising healthcare costs. In this context, we review the data that supports the appropriate use of imaging for breast cancer patients. We will discuss: 1) the optimal use of staging imaging in both early (Stage 0-II) and locally advanced (Stage III) breast cancer, 2) the role of surveillance imaging to detect recurrent disease in Stage 0-III breast cancer and 3) how patients with metastatic breast cancer should be followed with advanced imaging. Copyright © 2016 Elsevier Ltd. All rights reserved.
Optical imaging for breast cancer prescreening
Godavarty, Anuradha; Rodriguez, Suset; Jung, Young-Jin; Gonzalez, Stephanie
2015-01-01
Breast cancer prescreening is carried out prior to the gold standard screening using X-ray mammography and/or ultrasound. Prescreening is typically carried out using clinical breast examination (CBE) or self-breast examinations (SBEs). Since CBE and SBE have high false-positive rates, there is a need for a low-cost, noninvasive, non-radiative, and portable imaging modality that can be used as a prescreening tool to complement CBE/SBE. This review focuses on the various hand-held optical imaging devices that have been developed and applied toward early-stage breast cancer detection or as a prescreening tool via phantom, in vivo, and breast cancer imaging studies. Apart from the various optical devices developed by different research groups, a wide-field fiber-free near-infrared optical scanner has been developed for transillumination-based breast imaging in our Optical Imaging Laboratory. Preliminary in vivo studies on normal breast tissues, with absorption-contrasted targets placed in the intramammary fold, detected targets as deep as 8.8 cm. Future work involves in vivo imaging studies on breast cancer subjects and comparison with the gold standard X-ray mammography approach. PMID:26229503
Current and Future Methods for Measuring Breast Density: A Brief Comparative Review
Sak, Mark A.; Littrup, Peter J.; Duric, Neb; Mullooly, Maeve; Sherman, Mark E.; Gierach, Gretchen L.
2017-01-01
Breast density is one of the strongest predictors of breast cancer risk. Women with the densest breasts are 4 to 6 times more likely to develop cancer compared with those with the lowest densities. Breast density is generally assessed using mammographic imaging; however, this approach has limitations. Magnetic resonance imaging and ultrasound tomography are some alternative imaging modalities that can aid mammography in patient screening and the measurement of breast density. As breast density becomes more commonly discussed, knowledge of the advantages and limitations of breast density as a marker of risk will become more critical. This review article discusses the relationship between breast density and breast cancer risk, lists the benefits and drawbacks of using multiple different imaging modalities to measure density and briefly discusses how breast density will be applied to aid in breast cancer prevention and treatment. PMID:28943893
Paradigm Shifts in Breast Care Delivery: Impact of Imaging in a Multidisciplinary Environment.
Krishnamurthy, Savitri; Bevers, Therese; Kuerer, Henry M; Smith, Benjamin; Yang, Wei Tse
2017-02-01
The practice of breast imaging in a collaborative multidisciplinary environment adds significant value to outcomes in women's health care. In this article, we describe multidisciplinary considerations in breast cancer screening and early detection, the impact of imaging and histopathologic findings in the diagnostic evaluation and management of breast abnormalities, and the contribution of imaging to surgical and radiation therapy planning for the breast cancer patient. The multidisciplinary delivery of breast care for women that incorporates screening, diagnosis of borderline and high-risk lesions, and management of the breast cancer patient adds considerable value to outcomes in health care.
2009-10-01
molecular breast imaging, with the ability to dynamically contour any sized breast, will improve detection and potentially in vivo characterization of...Having flexible 3D positioning about the breast yielded minimal RMSD differences, which is important for high resolution molecular emission imaging. This...TITLE: Automation and Preclinical Evaluation of a Dedicated Emission Mammotomography System for Fully 3-D Molecular Breast Imaging PRINCIPAL
Molecular breast imaging using a dedicated high-performance instrument
NASA Astrophysics Data System (ADS)
O'Connor, Michael K.; Wagenaar, Douglas; Hruska, Carrie B.; Phillips, Stephen; Caravaglia, Gina; Rhodes, Deborah
2006-08-01
In women with radiographically dense breasts, the sensitivity of mammography is less than 50%. With the increase in the percent of women with dense breasts, it is important to look at alternative screening techniques for this population. This article reviews the strengths and weaknesses of current imaging techniques and focuses on recent developments in semiconductor-based gamma camera systems that offer significant improvements in image quality over that achievable with single-crystal sodium iodide systems. We have developed a technique known as Molecular Breast Imaging (MBI) using small field of view Cadmium Zinc Telluride (CZT) gamma cameras that permits the breast to be imaged in a similar manner to mammography, using light pain-free compression. Computer simulations and experimental studies have shown that use of low-energy high sensitivity collimation coupled with the excellent energy resolution and intrinsic spatial resolution of CZT detectors provides optimum image quality for the detection of small breast lesions. Preliminary clinical studies with a prototype dual-detector system have demonstrated that Molecular Breast Imaging has a sensitivity of ~90% for the detection of breast tumors less than 10 mm in diameter. By comparison, conventional scintimammography only achieves a sensitivity of 50% in the detection of lesions < 10 mm. Because Molecular Breast Imaging is not affected by breast density, this technique may offer an important adjunct to mammography in the evaluation of women with dense breast parenchyma.
Comparison of breast density measurements made using ultrasound tomography and mammography
NASA Astrophysics Data System (ADS)
Sak, Mark; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Krycia, Mark; Sherman, Mark E.; Boyd, Norman; Gierach, Gretchen L.
2015-03-01
Women with elevated mammographic percent density, defined as the ratio of fibroglandular tissue area to total breast area on a mammogram are at an increased risk of developing breast cancer. Ultrasound tomography (UST) is an imaging modality that can create tomographic sound speed images of a patient's breast, which can then be used to measure breast density. These sound speed images are useful because physical tissue density is directly proportional to sound speed. The work presented here updates previous results that compared mammographic breast density measurements with UST breast density measurements within an ongoing study. The current analysis has been expanded to include 158 women with negative digital mammographic screens who then underwent a breast UST scan. Breast density was measured for both imaging modalities and preliminary analysis demonstrated strong and positive correlations (Spearman correlation coefficient rs = 0.703). Additional mammographic and UST related imaging characteristics were also analyzed and used to compare the behavior of both imaging modalities. Results suggest that UST can be used among women with negative mammographic screens as a quantitative marker of breast density that may avert shortcomings of mammography.
Itsukage, Shizu; Sowa, Yoshihiro; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki
2017-01-01
Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes' principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging.
Itsukage, Shizu; Goto, Mariko; Taguchi, Tetsuya; Numajiri, Toshiaki
2017-01-01
Objective: Preoperative prediction of breast volume is important in the planning of breast reconstructive surgery. In this study, we prospectively estimated the accuracy of measurement of breast volume using data from 2 routine modalities, mammography and magnetic resonance imaging, by comparison with volumes of mastectomy specimens. Methods: The subjects were 22 patients (24 breasts) who were scheduled to undergo total mastectomy for breast cancer. Preoperatively, magnetic resonance imaging volume measurement was performed using a medical imaging system and the mammographic volume was calculated using a previously proposed formula. Volumes of mastectomy specimens were measured intraoperatively using a method based on Archimedes’ principle and Newton's third law. Results: The average breast volumes measured on magnetic resonance imaging and mammography were 318.47 ± 199.4 mL and 325.26 ± 217.36 mL, respectively. The correlation coefficients with mastectomy specimen volumes were 0.982 for magnetic resonance imaging and 0.911 for mammography. Conclusions: Breast volume measurement using magnetic resonance imaging was highly accurate but requires data analysis software. In contrast, breast volume measurement with mammography requires only a simple formula and is sufficiently accurate, although the accuracy was lower than that obtained with magnetic resonance imaging. These results indicate that mammography could be an alternative modality for breast volume measurement as a substitute for magnetic resonance imaging. PMID:29308107
TH-A-18A-01: Innovation in Clinical Breast Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, B; Yang, K; Yaffe, M
Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists.more » In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging.« less
Breast segmentation in MR images using three-dimensional spiral scanning and dynamic programming
NASA Astrophysics Data System (ADS)
Jiang, Luan; Lian, Yanyun; Gu, Yajia; Li, Qiang
2013-03-01
Magnetic resonance (MR) imaging has been widely used for risk assessment and diagnosis of breast cancer in clinic. To develop a computer-aided diagnosis (CAD) system, breast segmentation is the first important and challenging task. The accuracy of subsequent quantitative measurement of breast density and abnormalities depends on accurate definition of the breast area in the images. The purpose of this study is to develop and evaluate a fully automated method for accurate segmentation of breast in three-dimensional (3-D) MR images. A fast method was developed to identify bounding box, i.e., the volume of interest (VOI), for breasts. A 3-D spiral scanning method was used to transform the VOI of each breast into a single two-dimensional (2-D) generalized polar-coordinate image. Dynamic programming technique was applied to the transformed 2-D image for delineating the "optimal" contour of the breast. The contour of the breast in the transformed 2-D image was utilized to reconstruct the segmentation results in the 3-D MR images using interpolation and lookup table. The preliminary results on 17 cases show that the proposed method can obtain accurate segmentation of the breast based on subjective observation. By comparing with the manually delineated region of 16 breasts in 8 cases, an overlap index of 87.6% +/- 3.8% (mean +/- SD), and a volume agreement of 93.4% +/- 4.5% (mean +/- SD) were achieved, respectively. It took approximately 3 minutes for our method to segment the breast in an MR scan of 256 slices.
TH-AB-209-08: Next Generation Dedicated 3D Breast Imaging with XACT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, S; Chen, J; Samant, P
Purpose: Exposure to radiation increases the risk of cancer. We have designed a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, an X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to conventional breast CT. Methods: Theoretical calculations are done to determine the appropriate X-ray energy and ultrasound frequency in breast XACT imaging. A series of breast CT image along the coronal plane from a patient with calcifications in the breast tissue are used as the source image. HU value based segmentation ismore » done to distinguish the skin, adipose tissue, glandular tissue, breast calcification, and chest bone from each CT image. X-ray dose deposition in each pixel is calculated based on the tissue type by using GEANT4 Monte Carlo toolkits. The initial pressure rise caused by X-ray energy deposition is calculated according to tissue properties. Then, the X-ray induced acoustic wave propagation is simulated by K-WAVE toolkit. Breast XACT images are reconstructed from the recorded time-dependent ultrasound waves. Results: For imaging a breast with large size (16cm in diameter at chest wall), the photon energy of X-ray source and the central frequency of ultrasound detector is determined as 20keV and 5.5MHz. Approximately 10 times contrast between a calcification and the breast tissue can be acquire from XACT image. The calcification can be clearly identified from the reconstructed XACT image. Conclusion: XACT technique takes the advantages of X-ray absorption contrast and high ultrasonic resolution. With the proposed innovative technology, one can potentially reduce radiation dose to patient in 3D breast imaging as compared with current x-ray modalities, while still maintaining high imaging contrast and spatial resolution.« less
[Diagnostic imaging of breast cancer : An update].
Funke, M
2016-10-01
Advances in imaging of the female breast have substantially influenced the diagnosis and probably also the therapy and prognosis of breast cancer in the past few years. This article gives an overview of the most important imaging modalities in the diagnosis of breast cancer. Digital mammography is considered to be the gold standard for the early detection of breast cancer. Digital breast tomosynthesis can increase the diagnostic accuracy of mammography and is used for the assessment of equivocal or suspicious mammography findings. Other modalities, such as ultrasound and contrast-enhanced magnetic resonance imaging (MRI) play an important role in the diagnostics, staging and follow-up of breast cancer. Percutaneous needle biopsy is a rapid and minimally invasive method for the histological verification of breast cancer. New breast imaging modalities, such as contrast-enhanced spectral mammography, diffusion-weighted MRI and MR spectroscopy can possibly further improve breast cancer diagnostics; however, further studies are necessary to prove the advantages of these methods so that they cannot yet be recommended for routine clinical use.
Breast ultrasonography: state of the art.
Hooley, Regina J; Scoutt, Leslie M; Philpotts, Liane E
2013-09-01
Ultrasonography (US) is an indispensable tool in breast imaging and is complementary to both mammography and magnetic resonance (MR) imaging of the breast. Advances in US technology allow confident characterization of not only benign cysts but also benign and malignant solid masses. Knowledge and understanding of current and emerging US technology, along with the application of meticulous scanning technique, is imperative for image optimization and diagnosis. The ability to synthesize breast US findings with multiple imaging modalities and clinical information is also necessary to ensure the best patient care. US is routinely used to guide breast biopsies and is also emerging as a supplemental screening tool in women with dense breasts and a negative mammogram. This review provides a summary of current state-of-the-art US technology, including elastography, and applications of US in clinical practice as an adjuvant technique to mammography, MR imaging, and the clinical breast examination. The use of breast US for screening, preoperative staging for breast cancer, and breast intervention will also be discussed.
A review of biomechanically informed breast image registration
NASA Astrophysics Data System (ADS)
Hipwell, John H.; Vavourakis, Vasileios; Han, Lianghao; Mertzanidou, Thomy; Eiben, Björn; Hawkes, David J.
2016-01-01
Breast radiology encompasses the full range of imaging modalities from routine imaging via x-ray mammography, magnetic resonance imaging and ultrasound (both two- and three-dimensional), to more recent technologies such as digital breast tomosynthesis, and dedicated breast imaging systems for positron emission mammography and ultrasound tomography. In addition new and experimental modalities, such as Photoacoustics, Near Infrared Spectroscopy and Electrical Impedance Tomography etc, are emerging. The breast is a highly deformable structure however, and this greatly complicates visual comparison of imaging modalities for the purposes of breast screening, cancer diagnosis (including image guided biopsy), tumour staging, treatment monitoring, surgical planning and simulation of the effects of surgery and wound healing etc. Due primarily to the challenges posed by these gross, non-rigid deformations, development of automated methods which enable registration, and hence fusion, of information within and across breast imaging modalities, and between the images and the physical space of the breast during interventions, remains an active research field which has yet to translate suitable methods into clinical practice. This review describes current research in the field of breast biomechanical modelling and identifies relevant publications where the resulting models have been incorporated into breast image registration and simulation algorithms. Despite these developments there remain a number of issues that limit clinical application of biomechanical modelling. These include the accuracy of constitutive modelling, implementation of representative boundary conditions, failure to meet clinically acceptable levels of computational cost, challenges associated with automating patient-specific model generation (i.e. robust image segmentation and mesh generation) and the complexity of applying biomechanical modelling methods in routine clinical practice.
Use of Breast-Specific PET Scanners and Comparison with MR Imaging.
Narayanan, Deepa; Berg, Wendie A
2018-05-01
The goals of this article are to discuss the role of breast-specific PET imaging of women with breast cancer, compare the clinical performance of positron emission mammography (PEM) and MR imaging for current indications, and provide recommendations for when women should undergo PEM instead of breast MR imaging. Published by Elsevier Inc.
Prabha, S; Suganthi, S S; Sujatha, C M
2015-01-01
Breast thermography is a potential imaging method for the early detection of breast cancer. The pathological conditions can be determined by measuring temperature variations in the abnormal breast regions. Accurate delineation of breast tissues is reported as a challenging task due to inherent limitations of infrared images such as low contrast, low signal to noise ratio and absence of clear edges. Segmentation technique is attempted to delineate the breast tissues by detecting proper lower breast boundaries and inframammary folds. Characteristic features are extracted to analyze the asymmetrical thermal variations in normal and abnormal breast tissues. An automated analysis of thermal variations of breast tissues is attempted using nonlinear adaptive level sets and Riesz transform. Breast thermal images are initially subjected to Stein's unbiased risk estimate based orthonormal wavelet denoising. These denoised images are enhanced using contrast-limited adaptive histogram equalization method. The breast tissues are then segmented using non-linear adaptive level set method. The phase map of enhanced image is integrated into the level set framework for final boundary estimation. The segmented results are validated against the corresponding ground truth images using overlap and regional similarity metrics. The segmented images are further processed with Riesz transform and structural texture features are derived from the transformed coefficients to analyze pathological conditions of breast tissues. Results show that the estimated average signal to noise ratio of denoised images and average sharpness of enhanced images are improved by 38% and 6% respectively. The interscale consideration adopted in the denoising algorithm is able to improve signal to noise ratio by preserving edges. The proposed segmentation framework could delineate the breast tissues with high degree of correlation (97%) between the segmented and ground truth areas. Also, the average segmentation accuracy and sensitivity are found to be 98%. Similarly, the maximum regional overlap between segmented and ground truth images obtained using volume similarity measure is observed to be 99%. Directionality as a feature, showed a considerable difference between normal and abnormal tissues which is found to be 11%. The proposed framework for breast thermal image analysis that is aided with necessary preprocessing is found to be useful in assisting the early diagnosis of breast abnormalities.
Taylor, Liezel; Basro, Sarinah; Apffelstaedt, Justus P; Baatjes, Karin
2011-08-01
Mammography in younger women is considered to be of limited value. In a resource restricted environment without access to magnetic resonance imaging (MRI) and with a high incidence of breast cancer in the young, mammography remains an important diagnostic tool. Recent technical advances and better regulation of mammography make a reassessment of its value in these conditions necessary. Data of all the mammograms performed at a tertiary hospital and private breast clinic between January 2003 and July 2009 in women less than 40 years of age were collected. Indications were the presence of a mass, follow-up after primary cancer therapy, and screening for patients perceived at high risk due to a family history or the presence of atypical hyperplasia. Data acquired were as follows: Demographics, prior breast surgery, indication for mammography, outcome of mammography, diagnostic procedures, and their results. Of 2,167 mammograms, 393 were performed for a palpable mass, diagnostic mammography. In these, the overall cancer detection rate was 40%. If the mammography was reported as breast imaging reporting and data system (BIRADS(®)) 5 versus BIRADS(®) 3 and 4 versus BIRADS(®) 1 and 2, a final diagnosis of malignancy was established in 96, 48, and 5%, respectively. Of 367 mammograms done for the follow-up after primary treatment of breast cancer, seven cancers were diagnosed for a detection rate of 1.9%. Of 1,312 mammograms performed for screening, the recall rate was 4%; the biopsy rate 2%, and the cancer diagnosis rate 3/1,000 examinations. In contrast to past series, this series has shown that recent advances in mammography have made it a useful tool in the management of breast problems in young women, notably in a resource-restricted environment. Women for screening should be selected carefully.
NASA Astrophysics Data System (ADS)
Lau, Kristen C.; Lee, Hyo Min; Singh, Tanushriya; Maidment, Andrew D. A.
2015-03-01
Dual-energy contrast-enhanced digital breast tomosynthesis (DE CE-DBT) uses an iodinated contrast agent to image the three-dimensional breast vasculature. The University of Pennsylvania has an ongoing DE CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 post-contrast). DE images are obtained by a weighted logarithmic subtraction of the high-energy (HE) and low-energy (LE) image pairs. Temporal subtraction of the post-contrast DE images from the pre-contrast DE image is performed to analyze iodine uptake. Our previous work investigated image registration methods to correct for patient motion, enhancing the evaluation of vascular kinetics. In this project we investigate a segmentation algorithm which identifies blood vessels in the breast from our temporal DE subtraction images. Anisotropic diffusion filtering, Gabor filtering, and morphological filtering are used for the enhancement of vessel features. Vessel labeling methods are then used to distinguish vessel and background features successfully. Statistical and clinical evaluations of segmentation accuracy in DE-CBT images are ongoing.
A minimum spanning forest based classification method for dedicated breast CT images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pike, Robert; Sechopoulos, Ioannis; Fei, Baowei, E-mail: bfei@emory.edu
Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting modelmore » used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging.« less
High resolution PET breast imager with improved detection efficiency
Majewski, Stanislaw
2010-06-08
A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.
Value of diagnostic imaging for the symptomatic male breast: Can we avoid unnecessary biopsies?
Foo, Eric T; Lee, Amie Y; Ray, Kimberly M; Woodard, Genevieve A; Freimanis, Rita I; Joe, Bonnie N
To review the use of diagnostic breast imaging and outcomes for symptomatic male patients. We retrospectively evaluated 122 males who underwent diagnostic imaging for breast symptoms at our academic center. The majority (94%) of cases had negative or benign imaging, with gynecomastia being the most common diagnosis (78%). There were two malignancies, both of which had positive imaging. Fifteen patients underwent percutaneous biopsy, and over half (53%) were palpation-guided biopsies initiated by the referring clinician despite negative imaging. Diagnostic imaging demonstrated 100% sensitivity and 96% specificity for identifying cancer. Malignancy is rarely a cause of male breast symptoms. Diagnostic breast imaging is useful to establish benignity and avert unnecessary biopsies. Copyright © 2017 Elsevier Inc. All rights reserved.
Feeling like me again: a grounded theory of the role of breast reconstruction surgery in self-image.
McKean, L N; Newman, E F; Adair, P
2013-07-01
The present study aimed to develop a theoretical understanding of the role of breast reconstruction in women's self-image. Semi-structured interviews were conducted with 10 women from breast cancer support groups who had undergone breast reconstruction surgery. A grounded theory methodology was used to explore their experiences. The study generated a model of 'breast cancer, breast reconstruction and self-image', with a core category entitled 'feeling like me again' and two principal categories of 'normal appearance' and 'normal life'. A further two main categories, 'moving on' and 'image of sick person' were generated. The results indicated a role of breast reconstruction in several aspects of self-image including the restoration of pre-surgery persona, which further promoted adjustment. © 2013 John Wiley & Sons Ltd.
Breast cancer diagnosis: Imaging techniques and biochemical markers.
Jafari, Seyed Hamed; Saadatpour, Zahra; Salmaninejad, Arash; Momeni, Fatemeh; Mokhtari, Mojgan; Nahand, Javid Sadri; Rahmati, Majid; Mirzaei, Hamed; Kianmehr, Mojtaba
2018-07-01
Breast cancer is a complex disease which is found as the second cause of cancer-associated death among women. Accumulating of evidence indicated that various factors (i.e., gentical and envirmental factors) could be associated with initiation and progression of breast cancer. Diagnosis of breast cancer patients in early stages is one of important aspects of breast cancer treatment. Among of various diagnosis platforms, imaging techniques are main diagnosis approaches which could provide valuable data on patients with breast cancer. It has been showed that various imaging techniques such as mammography, magnetic resonance imaging (MRI), positron-emission tomography (PET), Computed tomography (CT), and single-photon emission computed tomography (SPECT) could be used for diagnosis and monitoring patients with breast cancer in various stages. Beside, imaging techniques, utilization of biochemical biomarkers such as proteins, DNAs, mRNAs, and microRNAs could be employed as new diagnosis and therapeutic tools for patients with breast cancer. Here, we summarized various imaging techniques and biochemical biomarkers could be utilized as diagnosis of patients with breast cancer. Moreover, we highlighted microRNAs and exosomes as new diagnosis and therapeutic biomarkers for monitoring patients with breast cancer. © 2017 Wiley Periodicals, Inc.
Automatic segmentation of mammogram and tomosynthesis images
NASA Astrophysics Data System (ADS)
Sargent, Dusty; Park, Sun Young
2016-03-01
Breast cancer is a one of the most common forms of cancer in terms of new cases and deaths both in the United States and worldwide. However, the survival rate with breast cancer is high if it is detected and treated before it spreads to other parts of the body. The most common screening methods for breast cancer are mammography and digital tomosynthesis, which involve acquiring X-ray images of the breasts that are interpreted by radiologists. The work described in this paper is aimed at optimizing the presentation of mammography and tomosynthesis images to the radiologist, thereby improving the early detection rate of breast cancer and the resulting patient outcomes. Breast cancer tissue has greater density than normal breast tissue, and appears as dense white image regions that are asymmetrical between the breasts. These irregularities are easily seen if the breast images are aligned and viewed side-by-side. However, since the breasts are imaged separately during mammography, the images may be poorly centered and aligned relative to each other, and may not properly focus on the tissue area. Similarly, although a full three dimensional reconstruction can be created from digital tomosynthesis images, the same centering and alignment issues can occur for digital tomosynthesis. Thus, a preprocessing algorithm that aligns the breasts for easy side-by-side comparison has the potential to greatly increase the speed and accuracy of mammogram reading. Likewise, the same preprocessing can improve the results of automatic tissue classification algorithms for mammography. In this paper, we present an automated segmentation algorithm for mammogram and tomosynthesis images that aims to improve the speed and accuracy of breast cancer screening by mitigating the above mentioned problems. Our algorithm uses information in the DICOM header to facilitate preprocessing, and incorporates anatomical region segmentation and contour analysis, along with a hidden Markov model (HMM) for processing the multi-frame tomosynthesis images. The output of the algorithm is a new set of images that have been processed to show only the diagnostically relevant region and align the breasts so that they can be easily compared side-by-side. Our method has been tested on approximately 750 images, including various examples of mammogram, tomosynthesis, and scanned images, and has correctly segmented the diagnostically relevant image region in 97% of cases.
Yu, Xiuyan; Hu, Guoming; Zhang, Zhigang; Qiu, Fuming; Shao, Xuan; Wang, Xiaochen; Zhan, Hongwei; Chen, Yiding; Deng, Yongchuan; Huang, Jian
2016-07-11
Diagnosing breast cancer during the early stage may be helpful for decreasing cancer-related mortality. In Western developed countries, mammographies have been the gold standard for breast cancer detection. However, Chinese women usually have denser and smaller-sized breasts compared to Caucasian women, which decreases the diagnostic accuracy of mammography. However, breast specific gamma imaging, a type of molecular functional breast imaging, has been used for the accurate diagnosis of breast cancer and is not influenced by breast density. Our objective was to analyze the breast specific gamma imaging (BSGI) diagnostic value for Chinese women. During a 2-year period, 357 women were diagnosed and treated at our oncology department and received BSGI in addition to mammography (MMG), ultrasound (US) and magnetic resonance imaging (MRI) for diagnostic assessment. We investigated the sensitivity and specificity of each method of detection and compared the biological profiles of the four imaging methods. A total of 357 women received a final surgical pathology diagnosis, with 168 malignant diseases (58.5 %) and 119 benign diseases (41.5 %). Of these, 166 underwent the four imaging tests preoperatively. The sensitivity of BSGI was 80.35 and 82.14 % by US, 75.6 % by MMG, and 94.06 % by MRI. Furthermore, the breast cancer diagnosis specificity of BSGI was high (83.19 % vs. 77.31 % vs. 66.39 % vs. 67.69 %, respectively). The BSGI diagnostic sensitivity for mammographic breast density in women was superior to mammography and more sensitive for non-luminal A subtypes (luminal A vs. non-luminal A, 68.63 % vs. 88.30 %). BSGI may help improve the ability to diagnose early stage breast cancer for Chinese women, particularly for ductal carcinoma in situ (DCIS), mammographic breast density and non-luminal A breast cancer.
Overutilization of Health Care Resources for Breast Pain.
Kushwaha, Anne C; Shin, Kyungmin; Kalambo, Megan; Legha, Ravinder; Gerlach, Karen E; Kapoor, Megha Madhukar; Yang, Wei T
2018-05-24
The objective of this study is to analyze the incidence of women with breast pain who present to an imaging center and assess the imaging findings, outcomes, and workup costs at breast imaging centers affiliated with one institution. Demographic characteristics of and imaging findings for female patients presenting with breast pain at three community breast imaging centers between January 1, 2014, and December 31, 2014, were reviewed. Patients who were pregnant, were lactating, had a history of breast cancer, or presented with palpable nipple or skin findings were excluded. A total of 799 patients met the study criteria. Pain was diffuse in 30%, was focal in 30%, and was not localized in 40%. Of the 799 patients with breast pain, 790 (99%) presented for a diagnostic evaluation; 759 (95%) of these evaluated patients had negative findings. A benign sonographic correlate was detected in the area of pain in 5% of patients (39/799). One patient had a single cancer detected in the contralateral asymptomatic breast. When correlations between breast pain and the presence of cancer in the study patients were compared with the concurrent cancer detection rate in the screening population (5.5 cases per 1000 examinations performed), breast pain was not found to be a sign of breast cancer (p = 0.027). Patients younger than 40 years (316/799) underwent a total of 454 workup studies for breast pain; all findings were benign, and the cost of these studies was $87,322. Patients 40 years or older (483/799) underwent 745 workup studies, for a cost of $152,732. Breast pain represents an area of overutilization of health care resources. For female patients who present with pure breast pain, breast imaging centers should consider the following imaging protocols and education for referring physicians: an annual screening mammogram should be recommended for women 40 years or older, and reassurance without imaging should be offered to patients younger than 40 years.
NASA Astrophysics Data System (ADS)
O'Halloran, M.; Lohfeld, S.; Ruvio, G.; Browne, J.; Krewer, F.; Ribeiro, C. O.; Inacio Pita, V. C.; Conceicao, R. C.; Jones, E.; Glavin, M.
2014-05-01
Breast cancer is one of the most common cancers in women. In the United States alone, it accounts for 31% of new cancer cases, and is second only to lung cancer as the leading cause of deaths in American women. More than 184,000 new cases of breast cancer are diagnosed each year resulting in approximately 41,000 deaths. Early detection and intervention is one of the most significant factors in improving the survival rates and quality of life experienced by breast cancer sufferers, since this is the time when treatment is most effective. One of the most promising breast imaging modalities is microwave imaging. The physical basis of active microwave imaging is the dielectric contrast between normal and malignant breast tissue that exists at microwave frequencies. The dielectric contrast is mainly due to the increased water content present in the cancerous tissue. Microwave imaging is non-ionizing, does not require breast compression, is less invasive than X-ray mammography, and is potentially low cost. While several prototype microwave breast imaging systems are currently in various stages of development, the design and fabrication of anatomically and dielectrically representative breast phantoms to evaluate these systems is often problematic. While some existing phantoms are composed of dielectrically representative materials, they rarely accurately represent the shape and size of a typical breast. Conversely, several phantoms have been developed to accurately model the shape of the human breast, but have inappropriate dielectric properties. This study will brie y review existing phantoms before describing the development of a more accurate and practical breast phantom for the evaluation of microwave breast imaging systems.
Issues to consider before implementing digital breast tomosynthesis into a breast imaging practice.
Hardesty, Lara A
2015-03-01
OBJECTIVE. The purpose of this article is to discuss issues surrounding the implementation of digital breast tomosynthesis (DBT) into a clinical breast imaging practice and assist radiologists, technologists, and administrators who are considering the addition of this new technology to their practices. CONCLUSION. When appropriate attention is given to image acquisition, interpretation, storage, technologist and radiologist training, patient selection, billing, radiation dose, and marketing, implementation of DBT into a breast imaging practice can be successful.
Evaluation of a new breast-shaped compensation filter for a newly built breast imaging system
NASA Astrophysics Data System (ADS)
Cai, Weixing; Ning, Ruola; Zhang, Yan; Conover, David
2007-03-01
A new breast-shaped compensation filter has been designed and fabricated for breast imaging using our newly built breast imaging (CBCTBI) system, which is able to scan an uncompressed breast with pendant geometry. The shape of this compensation filter is designed based on an average-sized breast phantom. Unlike conventional bow-tie compensation filters, its cross-sectional profile varies along the chest wall-to-nipple direction for better compensation for the shape of a breast. Breast phantoms of three different sizes are used to evaluate the performance of this compensation filter. The reconstruction image quality was studied and compared to that obtained without the compensation filter in place. The uniformity of linear attenuation coefficient and the uniformity of noise distribution are significantly improved, and the contrast-to-noise ratios (CNR) of small lesions near the chest wall are increased as well. Multi-normal image method is used in the reconstruction process to correct compensation flood field and to reduce ring artifacts.
Breast ultrasound tomography with two parallel transducer arrays: preliminary clinical results
NASA Astrophysics Data System (ADS)
Huang, Lianjie; Shin, Junseob; Chen, Ting; Lin, Youzuo; Intrator, Miranda; Hanson, Kenneth; Epstein, Katherine; Sandoval, Daniel; Williamson, Michael
2015-03-01
Ultrasound tomography has great potential to provide quantitative estimations of physical properties of breast tumors for accurate characterization of breast cancer. We design and manufacture a new synthetic-aperture breast ultrasound tomography system with two parallel transducer arrays. The distance of these two transducer arrays is adjustable for scanning breasts with different sizes. The ultrasound transducer arrays are translated vertically to scan the entire breast slice by slice and acquires ultrasound transmission and reflection data for whole-breast ultrasound imaging and tomographic reconstructions. We use the system to acquire patient data at the University of New Mexico Hospital for clinical studies. We present some preliminary imaging results of in vivo patient ultrasound data. Our preliminary clinical imaging results show promising of our breast ultrasound tomography system with two parallel transducer arrays for breast cancer imaging and characterization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nguyen, U; Kumaraswamy, N; Markey, M
Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution,more » with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality.« less
Lee-Felker, Stephanie A; Tekchandani, Leena; Thomas, Mariam; Gupta, Esha; Andrews-Tang, Denise; Roth, Antoinette; Sayre, James; Rahbar, Guita
2017-11-01
Purpose To compare the diagnostic performances of contrast material-enhanced spectral mammography and breast magnetic resonance (MR) imaging in the detection of index and secondary cancers in women with newly diagnosed breast cancer by using histologic or imaging follow-up as the standard of reference. Materials and Methods This institutional review board-approved, HIPAA-compliant, retrospective study included 52 women who underwent breast MR imaging and contrast-enhanced spectral mammography for newly diagnosed unilateral breast cancer between March 2014 and October 2015. Of those 52 patients, 46 were referred for contrast-enhanced spectral mammography and targeted ultrasonography because they had additional suspicious lesions at MR imaging. In six of the 52 patients, breast cancer had been diagnosed at an outside institution. These patients were referred for contrast-enhanced spectral mammography and targeted US as part of diagnostic imaging. Images from contrast-enhanced spectral mammography were analyzed by two fellowship-trained breast imagers with 2.5 years of experience with contrast-enhanced spectral mammography. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value were calculated for both imaging modalities and compared by using the Bennett statistic. Results Fifty-two women with 120 breast lesions were included for analysis (mean age, 50 years; range, 29-73 years). Contrast-enhanced spectral mammography had similar sensitivity to MR imaging (94% [66 of 70 lesions] vs 99% [69 of 70 lesions]), a significantly higher PPV than MR imaging (93% [66 of 71 lesions] vs 60% [69 of 115 lesions]), and fewer false-positive findings than MR imaging (five vs 45) (P < .001 for all results). In addition, contrast-enhanced spectral mammography depicted 11 of the 11 secondary cancers (100%) and MR imaging depicted 10 (91%). Conclusion Contrast-enhanced spectral mammography is potentially as sensitive as MR imaging in the evaluation of extent of disease in newly diagnosed breast cancer, with a higher PPV. © RSNA, 2017.
Body image concerns during pregnancy are associated with a shorter breast feeding duration.
Brown, Amy; Rance, J; Warren, L
2015-01-01
breast feeding is affected by numerous psycho-social factors. Antenatal concerns such as embarrassment regarding public feeding and the impact of breast feeding upon breast shape are known to lead to artificial milk use. However, although work has explored the relationship between maternal weight and infant feeding, wider body image concerns have not been examined. The aim of the current study was to explore the association between maternal body image concerns during pregnancy upon intended and actual breast feeding duration. a two stage self report questionnaire completed during pregnancy and at six months post partum. mothers were recruited from local mother and infant groups, nurseries and online mother and infant forums. 128 pregnant women completed both stages. phase one: completion of a questionnaire exploring body image during pregnancy (concerns about stretch marks, weight gain and appearance) and planned breast feeding duration during the second/third trimester of pregnancy (body image, weight, intended duration) followed by a second questionnaire measuring actual breast feeding duration and breast feeding experiences. factor analysis revealed three primary body image concerns: pregnancy body image, prospective postnatal body image and dieting during pregnancy. Higher concerns on all three factors were associated with both intended and actual shorter breast feeding duration. Amongst mothers who stopped breast feeding before six months, those with higher body image concerns were more likely to report stopping due to embarrassment or the perceived impact upon their breast shape. The relationship was not explained by maternal weight, although a higher residual weight gain at six months was associated with a shorter breast feeding duration. mothers who are affected negatively by changes to their body during pregnancy may be less likely to plan to or initiate breast feeding potentially due to underlying issues such as embarrassment or perceived impact of feeding upon their appearance. The findings are important to those working with women during pregnancy and the postpartum period in understanding the impact of body image upon intention and ability to initiate and continue breast feeding. Copyright © 2014 Elsevier Ltd. All rights reserved.
Mann, Steve D.; Perez, Kristy L.; McCracken, Emily K. E.; Shah, Jainil P.; Wong, Terence Z.; Tornai, Martin P.
2012-01-01
A pilot study is underway to quantify in vivo the uptake and distribution of Tc-99m Sestamibi in subjects without previous history of breast cancer using a dedicated SPECT-CT breast imaging system. Subjects undergoing diagnostic parathyroid imaging studies were consented and imaged as part of this IRB-approved breast imaging study. For each of the seven subjects, one randomly selected breast was imaged prone-pendant using the dedicated, compact breast SPECT-CT system underneath the shielded patient support. Iteratively reconstructed and attenuation and/or scatter corrected images were coregistered; CT images were segmented into glandular and fatty tissue by three different methods; the average concentration of Sestamibi was determined from the SPECT data using the CT-based segmentation and previously established quantification techniques. Very minor differences between the segmentation methods were observed, and the results indicate an average image-based in vivo Sestamibi concentration of 0.10 ± 0.16 μCi/mL with no preferential uptake by glandular or fatty tissues. PMID:22956950
Evaluation of collimation and imaging configuration in scintimammography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsui, B.M.W.; Frey, E.C.; Wessell, D.E.
1996-12-31
Conventional scintimammography (SM) with {sup 99m}Tc sestamibi has been limited to taking a single lateral view of the breast using a parallel-hole high resolution (LEHR) collimator. The collimator is placed close to the breast for best possible spatial resolution. However, the collimator geometry precludes imaging the breast from other views. We evaluated using a pinhole collimator instead of a LEHR collimator in SM for improved spatial resolution and detection efficiency, and to allow additional imaging views. Results from theoretical calculations indicated that pinhole collimators could be designed with higher spatial resolution and detection efficiency than LEHR when imaging small tomore » medium size breasts. The geometrical shape of the pinhole collimator allows imaging of the breasts from both the lateral and craniocaudal views. The dual-view images allow better determination of the location of the tumors within the breast and improved detection of tumors located in the medial region of the breast. A breast model that simulates the shape and composition of the breast and breast tumors with different sizes and locations was added to an existing 3D mathematical cardiac-torso (MCAT) phantom. A cylindrically shaped phantom with 10 cm diameter and spherical inserts with different sizes and {sup 99m}Tc sestamibi uptakes with respect to the background provide physical models of breast with tumors. Simulation studies using the breast and MCAT phantoms and experimental studies using the cylindrical phantom confirmed the utility of the pinhole collimator in SM for improved breast tumor detection.« less
Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience.
Aydoğan, Fatih; Arıkan, Akif Enes; Aytaç, Erman; Velidedeoğlu, Mehmet; Yılmaz, Mehmet Halit; Sager, Muhammet Sait; Çelik, Varol; Uras, Cihan
2016-01-01
Sentinel lymph node biopsy can be applied by using either blue dye or radionuclide method or both in breast cancer. Fluorescent imaging with indocyanine green is a new defined method. This study evaluates the applicability of sentinel lymph node biopsy via fluorescent indocyanine green. IC-VIEW (Pulsion Medical Systems AG, Munich, Germany) infrared visualization system was used for imaging. Two mL of indocyanine green was injected to visualize sentinel lymph nodes. After injection, subcutaneous lymphatics were traced and sentinel lymph nodes were found with simultaneous imaging. Sentinel lymph nodes were excised under fluorescent light guidance, and excised lymph nodes were examined histopathologically. Patients with sentinel lymph node metastases underwent axillary dissection. Four patients with sentinel lymph node biopsy due to breast cancer were included in the study. Sentinel lymph nodes were visualized with indocyanine green in all patients. The median number of excised sentinel lymph node was 2 (2-3). Two patients with lymph node metastasis underwent axillary dissection. No metastasis was detected in lymph nodes other than the sentinel nodes in patients with axillary dissection. There was no complication during and after the operation related to the method. According to our limited experience, sentinel lymph node biopsy under fluorescent indocyanine green guidance, which has an advantage of simultaneous visualization, is technically feasible.
Henseler, Helga; Smith, Joanna; Bowman, Adrian; Khambay, Balvinder S; Ju, Xiangyang; Ayoub, Ashraf; Ray, Arup K
2012-09-01
The latissimus dorsi muscle flap is a common method for the reconstruction of the breast following mastectomy. The study aimed to assess the quality of this reconstruction using a three-dimensional (3D) imaging method. The null hypothesis was that there was no difference in volume between the reconstructed breast and the opposite side. This study was conducted in forty-four patients who had had immediate unilateral breast reconstruction by latissimus dorsi muscle flap. The breast was captured using the 3D imaging system. Ten landmarks were digitised on the 3D images. The volume of each breast was measured by the application of Breast Analysis Tool software. The symmetry of the breast was measured using Procrustes analysis. The impact of breast position, orientation, size and intrinsic shape on the overall breast asymmetry was investigated. The null hypothesis was rejected. The reconstructed breast showed a significantly smaller volume when compared to the opposite side, p < 0.0001, a mean difference of 176.8 cc and 95% CI (103.5, 250.0). The shape and the position of the reconstructed breast were the main contributing factors to the measured asymmetry score. 3D imaging was efficient in evaluating the outcome of breast surgery. The latissimus dorsi muscle flap on its own for breast reconstruction did not restore the volume and shape of the breast fully lost due to complete mastectomy. The modification of this method and the selection of other or additional surgical techniques for breast reconstruction should be considered. The asymmetry analysis through reflection and Procrustes matching was a useful method for the objective shape analysis of the female breast and presented a new approach for breast shape assessment. The intrinsic breast shape and the positioning of the breast were major components of postoperative breast asymmetry. The reconstructed breast was smaller overall than the un-operated breast at a significant level when assessing the breast volume using the surface area. 3D imaging by multiple stereophotogrammetry was a useful tool for volume measurements, shape analysis and the evaluation of symmetry. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.
Sturgeon, Gregory M; Kiarashi, Nooshin; Lo, Joseph Y; Samei, E; Segars, W P
2016-05-01
The authors are developing a series of computational breast phantoms based on breast CT data for imaging research. In this work, the authors develop a program that will allow a user to alter the phantoms to simulate the effect of gravity and compression of the breast (craniocaudal or mediolateral oblique) making the phantoms applicable to multimodality imaging. This application utilizes a template finite-element (FE) breast model that can be applied to their presegmented voxelized breast phantoms. The FE model is automatically fit to the geometry of a given breast phantom, and the material properties of each element are set based on the segmented voxels contained within the element. The loading and boundary conditions, which include gravity, are then assigned based on a user-defined position and compression. The effect of applying these loads to the breast is computed using a multistage contact analysis in FEBio, a freely available and well-validated FE software package specifically designed for biomedical applications. The resulting deformation of the breast is then applied to a boundary mesh representation of the phantom that can be used for simulating medical images. An efficient script performs the above actions seamlessly. The user only needs to specify which voxelized breast phantom to use, the compressed thickness, and orientation of the breast. The authors utilized their FE application to simulate compressed states of the breast indicative of mammography and tomosynthesis. Gravity and compression were simulated on example phantoms and used to generate mammograms in the craniocaudal or mediolateral oblique views. The simulated mammograms show a high degree of realism illustrating the utility of the FE method in simulating imaging data of repositioned and compressed breasts. The breast phantoms and the compression software can become a useful resource to the breast imaging research community. These phantoms can then be used to evaluate and compare imaging modalities that involve different positioning and compression of the breast.
Benson, John C.; Idiyatullin, Djaudat; Snyder, Angela L.; Snyder, Carl J.; Hutter, Diane; Everson, Lenore I.; Eberly, Lynn E.; Nelson, Michael T.; Garwood, Michael
2015-01-01
Purpose To report the results of sweep imaging with Fourier transformation (SWIFT) magnetic resonance (MR) imaging for diagnostic breast imaging. Materials and Methods Informed consent was obtained from all participants under one of two institutional review board–approved, HIPAA-compliant protocols. Twelve female patients (age range, 19–54 years; mean age, 41.2 years) and eight normal control subjects (age range, 22–56 years; mean age, 43.2 years) enrolled and completed the study from January 28, 2011, to March 5, 2013. Patients had previous lesions that were Breast Imaging Reporting and Data System 4 and 5 based on mammography and/or ultrasonographic imaging. Contrast-enhanced SWIFT imaging was completed by using a 4-T research MR imaging system. Noncontrast studies were completed in the normal control subjects. One of two sized single-breast SWIFT-compatible transceiver coils was used for nine patients and five controls. Three patients and five control subjects used a SWIFT-compatible dual breast coil. Temporal resolution was 5.9–7.5 seconds. Spatial resolution was 1.00 mm isotropic, with later examinations at 0.67 mm isotropic, and dual breast at 1.00 mm or 0.75 mm isotropic resolution. Results Two nonblinded breast radiologists reported SWIFT image findings of normal breast tissue, benign fibroadenomas (six of six lesions), and malignant lesions (10 of 12 lesions) concordant with other imaging modalities and pathologic reports. Two lesions in two patients were not visualized because of coil field of view. The images yielded by SWIFT showed the presence and extent of known breast lesions. Conclusion The SWIFT technique could become an important addition to breast imaging modalities because it provides high spatial resolution at all points during the dynamic contrast-enhanced examination. © RSNA, 2014 PMID:25247405
ED breast cases and other breast emergencies.
Khadem, Nasim; Reddy, Sravanthi; Lee, Sandy; Larsen, Linda; Walker, Daphne
2016-02-01
Patients with pathologic processes of the breast commonly present in the Emergency Department (ED). Familiarity with the imaging and management of the most common entities is essential for the radiologist. Additionally, it is important to understand the limitations of ED imaging and management in the acute setting and to recognize when referrals to a specialty breast center are necessary. The goal of this article is to review the clinical presentations, pathophysiology, imaging, and management of emergency breast cases and common breast pathology seen in the ED.
Imaging Surveillance After Primary Breast Cancer Treatment
Lam, Diana L.; Houssami, Nehmat; Lee, Janie M.
2017-01-01
OBJECTIVE Current clinical guidelines are consistent in supporting annual mammography for women after treatment of primary breast cancer. Surveillance imaging beyond standard digital mammography, including digital breast tomosynthesis (DBT), breast ultrasound, and MRI, may improve outcomes. This article reviews the evidence on the performance and effectiveness of breast imaging modalities available for surveillance after treatment of sporadic unilateral primary breast cancer and identifies additional factors to be considered when selecting an imaging surveillance regimen. CONCLUSION Evidence review supports the use of mammography for surveillance after primary breast cancer treatment. Variability exists in guideline recommendations for surveillance initiation, interval, and cessation. DBT offers the most promise as a potential modality to replace standard digital mammography as a front-line surveillance test; a single published study to date has shown a significant decrease in recall rates compared with standard digital mammography alone. Most guidelines do not support the use of whole-breast ultrasound in breast cancer surveillance, and further studies are needed to define the characteristics of women who may benefit from MRI surveillance. The emerging evidence about surveillance imaging outcomes suggests that additional factors, including patient and imaging characteristics, tumor biology and gene expression profile, and choice of treatment, warrant consideration in selecting personalized posttreatment imaging surveillance regimens. PMID:28075622
Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei
2012-10-01
To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors' classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors' automatic classification and manual segmentation were 91.6% ± 2.0%. A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution.
Yang, Xiaofeng; Wu, Shengyong; Sechopoulos, Ioannis; Fei, Baowei
2012-01-01
Purpose: To develop and test an automated algorithm to classify the different tissues present in dedicated breast CT images. Methods: The original CT images are first corrected to overcome cupping artifacts, and then a multiscale bilateral filter is used to reduce noise while keeping edge information on the images. As skin and glandular tissues have similar CT values on breast CT images, morphologic processing is used to identify the skin mask based on its position information. A modified fuzzy C-means (FCM) classification method is then used to classify breast tissue as fat and glandular tissue. By combining the results of the skin mask with the FCM, the breast tissue is classified as skin, fat, and glandular tissue. To evaluate the authors’ classification method, the authors use Dice overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on eight patient images. Results: The correction method was able to correct the cupping artifacts and improve the quality of the breast CT images. For glandular tissue, the overlap ratios between the authors’ automatic classification and manual segmentation were 91.6% ± 2.0%. Conclusions: A cupping artifact correction method and an automatic classification method were applied and evaluated for high-resolution dedicated breast CT images. Breast tissue classification can provide quantitative measurements regarding breast composition, density, and tissue distribution. PMID:23039675
Evaluation of the BreastSimulator software platform for breast tomography
NASA Astrophysics Data System (ADS)
Mettivier, G.; Bliznakova, K.; Sechopoulos, I.; Boone, J. M.; Di Lillo, F.; Sarno, A.; Castriconi, R.; Russo, P.
2017-08-01
The aim of this work was the evaluation of the software BreastSimulator, a breast x-ray imaging simulation software, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of computed tomography (CT) scanners dedicated to the breast. Eight 3D digital breast phantoms were created with glandular fractions in the range 10%-35%. The models are characterised by different sizes and modelled realistic anatomical features. X-ray CT projections were simulated for a dedicated cone-beam CT scanner and reconstructed with the FDK algorithm. X-ray projection images were simulated for 5 mono-energetic (27, 32, 35, 43 and 51 keV) and 3 poly-energetic x-ray spectra typically employed in current CT scanners dedicated to the breast (49, 60, or 80 kVp). Clinical CT images acquired from two different clinical breast CT scanners were used for comparison purposes. The quantitative evaluation included calculation of the power-law exponent, β, from simulated and real breast tomograms, based on the power spectrum fitted with a function of the spatial frequency, f, of the form S(f) = α/f β . The breast models were validated by comparison against clinical breast CT and published data. We found that the calculated β coefficients were close to that of clinical CT data from a dedicated breast CT scanner and reported data in the literature. In evaluating the software package BreastSimulator to generate breast models suitable for use with breast CT imaging, we found that the breast phantoms produced with the software tool can reproduce the anatomical structure of real breasts, as evaluated by calculating the β exponent from the power spectral analysis of simulated images. As such, this research tool might contribute considerably to the further development, testing and optimisation of breast CT imaging techniques.
Identifying women with dense breasts at high risk for interval cancer: a cohort study.
Kerlikowske, Karla; Zhu, Weiwei; Tosteson, Anna N A; Sprague, Brian L; Tice, Jeffrey A; Lehman, Constance D; Miglioretti, Diana L
2015-05-19
Twenty-one states have laws requiring that women be notified if they have dense breasts and that they be advised to discuss supplemental imaging with their provider. To better direct discussions of supplemental imaging by determining which combinations of breast cancer risk and Breast Imaging Reporting and Data System (BI-RADS) breast density categories are associated with high interval cancer rates. Prospective cohort. Breast Cancer Surveillance Consortium (BCSC) breast imaging facilities. 365,426 women aged 40 to 74 years who had 831,455 digital screening mammography examinations. BI-RADS breast density, BCSC 5-year breast cancer risk, and interval cancer rate (invasive cancer ≤12 months after a normal mammography result) per 1000 mammography examinations. High interval cancer rate was defined as more than 1 case per 1000 examinations. High interval cancer rates were observed for women with 5-year risk of 1.67% or greater and extremely dense breasts or 5-year risk of 2.50% or greater and heterogeneously dense breasts (24% of all women with dense breasts). The interval rate of advanced-stage disease was highest (>0.4 case per 1000 examinations) among women with 5-year risk of 2.50% or greater and heterogeneously or extremely dense breasts (21% of all women with dense breasts). Five-year risk was low to average (0% to 1.66%) for 51.0% of women with heterogeneously dense breasts and 52.5% with extremely dense breasts, with interval cancer rates of 0.58 to 0.63 and 0.72 to 0.89 case per 1000 examinations, respectively. The benefit of supplemental imaging was not assessed. Breast density should not be the sole criterion for deciding whether supplemental imaging is justified because not all women with dense breasts have high interval cancer rates. BCSC 5-year risk combined with BI-RADS breast density can identify women at high risk for interval cancer to inform patient-provider discussions about alternative screening strategies. National Cancer Institute.
TU-CD-BRA-01: A Novel 3D Registration Method for Multiparametric Radiological Images
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akhbardeh, A; Parekth, VS; Jacobs, MA
2015-06-15
Purpose: Multiparametric and multimodality radiological imaging methods, such as, magnetic resonance imaging(MRI), computed tomography(CT), and positron emission tomography(PET), provide multiple types of tissue contrast and anatomical information for clinical diagnosis. However, these radiological modalities are acquired using very different technical parameters, e.g.,field of view(FOV), matrix size, and scan planes, which, can lead to challenges in registering the different data sets. Therefore, we developed a hybrid registration method based on 3D wavelet transformation and 3D interpolations that performs 3D resampling and rotation of the target radiological images without loss of information Methods: T1-weighted, T2-weighted, diffusion-weighted-imaging(DWI), dynamic-contrast-enhanced(DCE) MRI and PET/CT were usedmore » in the registration algorithm from breast and prostate data at 3T MRI and multimodality(PET/CT) cases. The hybrid registration scheme consists of several steps to reslice and match each modality using a combination of 3D wavelets, interpolations, and affine registration steps. First, orthogonal reslicing is performed to equalize FOV, matrix sizes and the number of slices using wavelet transformation. Second, angular resampling of the target data is performed to match the reference data. Finally, using optimized angles from resampling, 3D registration is performed using similarity transformation(scaling and translation) between the reference and resliced target volume is performed. After registration, the mean-square-error(MSE) and Dice Similarity(DS) between the reference and registered target volumes were calculated. Results: The 3D registration method registered synthetic and clinical data with significant improvement(p<0.05) of overlap between anatomical structures. After transforming and deforming the synthetic data, the MSE and Dice similarity were 0.12 and 0.99. The average improvement of the MSE in breast was 62%(0.27 to 0.10) and prostate was 63%(0.13 to 0.04;p<0.05). The Dice similarity was in breast 8%(0.91 to 0.99) and for prostate was 89%(0.01 to 0.90;p<0.05) Conclusion: Our 3D wavelet hybrid registration approach registered diverse breast and prostate data of different radiological images(MR/PET/CT) with a high accuracy.« less
Breast surface estimation for radar-based breast imaging systems.
Williams, Trevor C; Sill, Jeff M; Fear, Elise C
2008-06-01
Radar-based microwave breast-imaging techniques typically require the antennas to be placed at a certain distance from or on the breast surface. This requires prior knowledge of the breast location, shape, and size. The method proposed in this paper for obtaining this information is based on a modified tissue sensing adaptive radar algorithm. First, a breast surface detection scan is performed. Data from this scan are used to localize the breast by creating an estimate of the breast surface. If required, the antennas may then be placed at specified distances from the breast surface for a second tumor-sensing scan. This paper introduces the breast surface estimation and antenna placement algorithms. Surface estimation and antenna placement results are demonstrated on three-dimensional breast models derived from magnetic resonance images.
Image Based Biomarker of Breast Cancer Risk: Analysis of Risk Disparity among Minority Populations
2013-03-01
TITLE: Image Based Biomarker of Breast Cancer Risk: Analysis of Risk Disparity among Minority Populations PRINCIPAL INVESTIGATOR: Fengshan Liu...SUBTITLE 5a. CONTRACT NUMBER Image Based Biomarker of Breast Cancer Risk: Analysis of Risk Disparity among Minority Populations 5b. GRANT NUMBER...identifying the prevalence of women with incomplete visualization of the breast . We developed a code to estimate the breast cancer risks using the
Breast prosthesis: Management of patients after plastic surgery
Bassetti, E.; Pediconi, F.; Luciani, M.L.; Santucci, E.; Miglio, E.; Candreva, R.
2011-01-01
Breast augmentation and breast reconstruction are increasingly common operations. All radiologists need to be able to recognize the normal appearances of the more commonly used implants on various imaging modalities and breast radiologists in particular are facing new challenges when imaging the women involved. This work aims to review the normal and abnormal findings in women undergoing breast implant surgery using ultrasonography, mammography, and magnetic resonance imaging. PMID:23396957
Microwave Sensors for Breast Cancer Detection
2018-01-01
Breast cancer is the leading cause of death among females, early diagnostic methods with suitable treatments improve the 5-year survival rates significantly. Microwave breast imaging has been reported as the most potential to become the alternative or additional tool to the current gold standard X-ray mammography for detecting breast cancer. The microwave breast image quality is affected by the microwave sensor, sensor array, the number of sensors in the array and the size of the sensor. In fact, microwave sensor array and sensor play an important role in the microwave breast imaging system. Numerous microwave biosensors have been developed for biomedical applications, with particular focus on breast tumor detection. Compared to the conventional medical imaging and biosensor techniques, these microwave sensors not only enable better cancer detection and improve the image resolution, but also provide attractive features such as label-free detection. This paper aims to provide an overview of recent important achievements in microwave sensors for biomedical imaging applications, with particular focus on breast cancer detection. The electric properties of biological tissues at microwave spectrum, microwave imaging approaches, microwave biosensors, current challenges and future works are also discussed in the manuscript. PMID:29473867
The potential of multiparametric MRI of the breast
Pinker, Katja; Helbich, Thomas H
2017-01-01
MRI is an essential tool in breast imaging, with multiple established indications. Dynamic contrast-enhanced MRI (DCE-MRI) is the backbone of any breast MRI protocol and has an excellent sensitivity and good specificity for breast cancer diagnosis. DCE-MRI provides high-resolution morphological information, as well as some functional information about neoangiogenesis as a tumour-specific feature. To overcome limitations in specificity, several other functional MRI parameters have been investigated and the application of these combined parameters is defined as multiparametric MRI (mpMRI) of the breast. MpMRI of the breast can be performed at different field strengths (1.5–7 T) and includes both established (diffusion-weighted imaging, MR spectroscopic imaging) and novel MRI parameters (sodium imaging, chemical exchange saturation transfer imaging, blood oxygen level-dependent MRI), as well as hybrid imaging with positron emission tomography (PET)/MRI and different radiotracers. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the underlying oncogenic processes of cancer development and progression and can provide additional specificity. This article will review the current and emerging functional parameters for mpMRI of the breast for improved diagnostic accuracy in breast cancer. PMID:27805423
Microwave Sensors for Breast Cancer Detection.
Wang, Lulu
2018-02-23
Breast cancer is the leading cause of death among females, early diagnostic methods with suitable treatments improve the 5-year survival rates significantly. Microwave breast imaging has been reported as the most potential to become the alternative or additional tool to the current gold standard X-ray mammography for detecting breast cancer. The microwave breast image quality is affected by the microwave sensor, sensor array, the number of sensors in the array and the size of the sensor. In fact, microwave sensor array and sensor play an important role in the microwave breast imaging system. Numerous microwave biosensors have been developed for biomedical applications, with particular focus on breast tumor detection. Compared to the conventional medical imaging and biosensor techniques, these microwave sensors not only enable better cancer detection and improve the image resolution, but also provide attractive features such as label-free detection. This paper aims to provide an overview of recent important achievements in microwave sensors for biomedical imaging applications, with particular focus on breast cancer detection. The electric properties of biological tissues at microwave spectrum, microwave imaging approaches, microwave biosensors, current challenges and future works are also discussed in the manuscript.
Veronesi, Paolo; De Lorenzi, Francesca; Loschi, Pietro; Rietjens, Mario; Veronesi, Umberto
2016-04-01
Breast augmentation is the most common cosmetic surgery in the United States, and thousands of augmented patients develop breast cancer each year. The possible effects of implants on cancer incidence, diagnosis, and treatment usually generate a disarming confusion. The present paper represents an update of the more recent oncologic and surgical strategies, aiming to support plastic and general surgeons in such challenging aspects. Several aspects of breast cancer management in augmented women are investigated, including (1) risk estimation and cancer characteristics, stage at diagnosis, and prognosis; (2) cancer diagnosis with clinical examination, mammography, ultrasound, and magnetic resonance imaging; (3) cancer treatment including breast conservation, intraoperative radiotherapy, sentinel node biopsy and mastectomy, and reconstruction. A brief resume of recommendations and conclusions is suggested, elucidating correct trends in the oncologic management of augmented patients and refusing well-established misconceptions: (1) breast augmentation does not increase the risk of breast cancer incidence, and it does not influence the prognosis; (2) possible risks exist in cancer detection due to technical difficulties; (3) sentinel lymph node detection is feasible; (4) intraoperative radiotherapy represents a good chance for conserving treatment; (5) immediate reconstruction with submuscular-subfascial implants is the most common procedure after mastectomy, and biological substitutes could support this procedure. Breast clinicians should be alerted because of high expectations of this subgroup of patients, accustomed to emphasize the aesthetic result. This journal requires that the authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Neuschler, Erin I; Butler, Reni; Young, Catherine A; Barke, Lora D; Bertrand, Margaret L; Böhm-Vélez, Marcela; Destounis, Stamatia; Donlan, Pamela; Grobmyer, Stephen R; Katzen, Janine; Kist, Kenneth A; Lavin, Philip T; Makariou, Erini V; Parris, Tchaiko M; Schilling, Kathy J; Tucker, F Lee; Dogan, Basak E
2018-05-01
Purpose To compare the diagnostic utility of an investigational optoacoustic imaging device that fuses laser optical imaging (OA) with grayscale ultrasonography (US) to grayscale US alone in differentiating benign and malignant breast masses. Materials and Methods This prospective, 16-site study of 2105 women (study period: 12/21/2012 to 9/9/2015) compared Breast Imaging Reporting and Data System (BI-RADS) categories assigned by seven blinded independent readers to benign and malignant breast masses using OA/US versus US alone. BI-RADS 3, 4, or 5 masses assessed at diagnostic US with biopsy-proven histologic findings and BI-RADS 3 masses stable at 12 months were eligible. Independent readers reviewed US images obtained with the OA/US device, assigned a probability of malignancy (POM) and BI-RADS category, and locked results. The same independent readers then reviewed OA/US images, scored OA features, and assigned OA/US POM and a BI-RADS category. Specificity and sensitivity were calculated for US and OA/US. Benign and malignant mass upgrade and downgrade rates, positive and negative predictive values, and positive and negative likelihood ratios were compared. Results Of 2105 consented subjects with 2191 masses, 100 subjects (103 masses) were analyzed separately as a training population and excluded. An additional 202 subjects (210 masses) were excluded due to technical failures or incomplete imaging, 72 subjects (78 masses) due to protocol deviations, and 41 subjects (43 masses) due to high-risk histologic results. Of 1690 subjects with 1757 masses (1079 [61.4%] benign and 678 [38.6%] malignant masses), OA/US downgraded 40.8% (3078/7535) of benign mass reads, with a specificity of 43.0% (3242/7538, 99% confidence interval [CI]: 40.4%, 45.7%) for OA/US versus 28.1% (2120/7543, 99% CI: 25.8%, 30.5%) for the internal US of the OA/US device. OA/US exceeded US in specificity by 14.9% (P < .0001; 99% CI: 12.9, 16.9%). Sensitivity for biopsied malignant masses was 96.0% (4553/4745, 99% CI: 94.5%, 97.0%) for OA/US and 98.6% (4680/4746, 99% CI: 97.8%, 99.1%) for US (P < .0001). The negative likelihood ratio of 0.094 for OA/US indicates a negative examination can reduce a maximum US-assigned pretest probability of 17.8% (low BI-RADS 4B) to a posttest probability of 2% (BI-RADS 3). Conclusion OA/US increases the specificity of breast mass assessment compared with the device internal grayscale US alone. Online supplemental material is available for this article. © RSNA, 2017.
NASA Astrophysics Data System (ADS)
Makeev, Andrey; Ikejimba, Lynda; Lo, Joseph Y.; Glick, Stephen J.
2016-03-01
Although digital mammography has reduced breast cancer mortality by approximately 30%, sensitivity and specificity are still far from perfect. In particular, the performance of mammography is especially limited for women with dense breast tissue. Two out of every three biopsies performed in the U.S. are unnecessary, thereby resulting in increased patient anxiety, pain, and possible complications. One promising tomographic breast imaging method that has recently been approved by the FDA is dedicated breast computed tomography (BCT). However, visualizing lesions with BCT can still be challenging for women with dense breast tissue due to the minimal contrast for lesions surrounded by fibroglandular tissue. In recent years there has been renewed interest in improving lesion conspicuity in x-ray breast imaging by administration of an iodinated contrast agent. Due to the fully 3-D imaging nature of BCT, as well as sub-optimal contrast enhancement while the breast is under compression with mammography and breast tomosynthesis, dedicated BCT of the uncompressed breast is likely to offer the best solution for injected contrast-enhanced x-ray breast imaging. It is well known that use of statistically-based iterative reconstruction in CT results in improved image quality at lower radiation dose. Here we investigate possible improvements in image reconstruction for BCT, by optimizing free regularization parameter in method of maximum likelihood and comparing its performance with clinical cone-beam filtered backprojection (FBP) algorithm.
Song, Sung Eun; Shin, Sung Ui; Moon, Hyeong-Gon; Ryu, Han Suk; Kim, Kwangsoo; Moon, Woo Kyung
2017-04-01
Preoperative breast magnetic resonance (MR) imaging features of primary breast cancers may have the potential to act as prognostic biomarkers by providing morphologic and kinetic features representing inter- or intra-tumor heterogeneity. Recent radiogenomic studies reveal that several radiologist-annotated image features are associated with genes or signal pathways involved in tumor progression, treatment resistance, and distant metastasis (DM). We investigate whether preoperative breast MR imaging features are associated with worse DM-free survival in patients with invasive breast cancer. Of the 3536 patients with primary breast cancers who underwent preoperative MR imaging between 2003 and 2009, 147 patients with DM were identified and one-to-one matched with control patients (n = 147) without DM according to clinical-pathologic variables. Three radiologists independently reviewed the MR images of 294 patients, and the association of DM-free survival with MR imaging and clinical-pathologic features was assessed using Cox proportional hazard models. Of MR imaging features, rim enhancement (hazard ratio [HR], 1.83 [95% confidence interval, CI 1.29, 2.51]; p = 0.001) and peritumoral edema (HR, 1.48 [95% CI 1.03, 2.11]; p = 0.032) were the significant features associated with worse DM-free survival. The significant MR imaging features, however, were different between breast cancer subtypes and stages. Preoperative breast MR imaging features of rim enhancement and peritumoral edema may be used as prognostic biomarkers that help predict DM risk in patients with breast cancer, thereby potentially enabling improved personalized treatment and monitoring strategies for individual patients.
SU-F-I-14: 3D Breast Digital Phantom for XACT Imaging
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tang, S; Laaroussi, R; Chen, J
Purpose: The X-ray induced acoustic computed tomography (XACT) is a new imaging modality which combines X-ray contrast and high ultrasonic resolution in a single modality. Using XACT in breast imaging, a 3D breast volume can be imaged by only one pulsed X-ray radiation, which could dramatically reduce the imaging dose for patients undergoing breast cancer screening and diagnosis. A 3D digital phantom that contains both X-ray properties and acoustic properties of different tissue types is indeed needed for developing and optimizing the XACT system. The purpose of this study is to offer a realistic breast digital phantom as a valuablemore » tool for improving breast XACT imaging techniques and potentially leading to better diagnostic outcomes. Methods: A series of breast CT images along the coronal plane from a patient who has breast calcifications are used as the source images. A HU value based segmentation algorithm is employed to identify breast tissues in five categories, namely the skin tissue, fat tissue, glandular tissue, chest bone and calcifications. For each pixel, the dose related parameters, such as material components and density, and acoustic related parameters, such as frequency-dependent acoustic attenuation coefficient and bandwidth, are assigned based on tissue types. Meanwhile, other parameters which are used in sound propagation, including the sound speed, thermal expansion coefficient, and heat capacity are also assigned to each tissue. Results: A series of 2D tissue type image is acquired first and the 3D digital breast phantom is obtained by using commercial 3D reconstruction software. When giving specific settings including dose depositions and ultrasound center frequency, the X-ray induced initial pressure rise can be calculated accordingly. Conclusion: The proposed 3D breast digital phantom represents a realistic breast anatomic structure and provides a valuable tool for developing and evaluating the system performance for XACT.« less
Using x-ray mammograms to assist in microwave breast image interpretation.
Curtis, Charlotte; Frayne, Richard; Fear, Elise
2012-01-01
Current clinical breast imaging modalities include ultrasound, magnetic resonance (MR) imaging, and the ubiquitous X-ray mammography. Microwave imaging, which takes advantage of differing electromagnetic properties to obtain image contrast, shows potential as a complementary imaging technique. As an emerging modality, interpretation of 3D microwave images poses a significant challenge. MR images are often used to assist in this task, and X-ray mammograms are readily available. However, X-ray mammograms provide 2D images of a breast under compression, resulting in significant geometric distortion. This paper presents a method to estimate the 3D shape of the breast and locations of regions of interest from standard clinical mammograms. The technique was developed using MR images as the reference 3D shape with the future intention of using microwave images. Twelve breast shapes were estimated and compared to ground truth MR images, resulting in a skin surface estimation accurate to within an average Euclidean distance of 10 mm. The 3D locations of regions of interest were estimated to be within the same clinical area of the breast as corresponding regions seen on MR imaging. These results encourage investigation into the use of mammography as a source of information to assist with microwave image interpretation as well as validation of microwave imaging techniques.
Augmented Reality Imaging System: 3D Viewing of a Breast Cancer.
Douglas, David B; Boone, John M; Petricoin, Emanuel; Liotta, Lance; Wilson, Eugene
2016-01-01
To display images of breast cancer from a dedicated breast CT using Depth 3-Dimensional (D3D) augmented reality. A case of breast cancer imaged using contrast-enhanced breast CT (Computed Tomography) was viewed with the augmented reality imaging, which uses a head display unit (HDU) and joystick control interface. The augmented reality system demonstrated 3D viewing of the breast mass with head position tracking, stereoscopic depth perception, focal point convergence and the use of a 3D cursor and joy-stick enabled fly through with visualization of the spiculations extending from the breast cancer. The augmented reality system provided 3D visualization of the breast cancer with depth perception and visualization of the mass's spiculations. The augmented reality system should be further researched to determine the utility in clinical practice.
Vidić, Igor; Egnell, Liv; Jerome, Neil P; Teruel, Jose R; Sjøbakk, Torill E; Østlie, Agnes; Fjøsne, Hans E; Bathen, Tone F; Goa, Pål Erik
2018-05-01
Diffusion-weighted MRI (DWI) is currently one of the fastest developing MRI-based techniques in oncology. Histogram properties from model fitting of DWI are useful features for differentiation of lesions, and classification can potentially be improved by machine learning. To evaluate classification of malignant and benign tumors and breast cancer subtypes using support vector machine (SVM). Prospective. Fifty-one patients with benign (n = 23) and malignant (n = 28) breast tumors (26 ER+, whereof six were HER2+). Patients were imaged with DW-MRI (3T) using twice refocused spin-echo echo-planar imaging with echo time / repetition time (TR/TE) = 9000/86 msec, 90 × 90 matrix size, 2 × 2 mm in-plane resolution, 2.5 mm slice thickness, and 13 b-values. Apparent diffusion coefficient (ADC), relative enhanced diffusivity (RED), and the intravoxel incoherent motion (IVIM) parameters diffusivity (D), pseudo-diffusivity (D*), and perfusion fraction (f) were calculated. The histogram properties (median, mean, standard deviation, skewness, kurtosis) were used as features in SVM (10-fold cross-validation) for differentiation of lesions and subtyping. Accuracies of the SVM classifications were calculated to find the combination of features with highest prediction accuracy. Mann-Whitney tests were performed for univariate comparisons. For benign versus malignant tumors, univariate analysis found 11 histogram properties to be significant differentiators. Using SVM, the highest accuracy (0.96) was achieved from a single feature (mean of RED), or from three feature combinations of IVIM or ADC. Combining features from all models gave perfect classification. No single feature predicted HER2 status of ER + tumors (univariate or SVM), although high accuracy (0.90) was achieved with SVM combining several features. Importantly, these features had to include higher-order statistics (kurtosis and skewness), indicating the importance to account for heterogeneity. Our findings suggest that SVM, using features from a combination of diffusion models, improves prediction accuracy for differentiation of benign versus malignant breast tumors, and may further assist in subtyping of breast cancer. 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:1205-1216. © 2017 International Society for Magnetic Resonance in Medicine.
NASA Astrophysics Data System (ADS)
Lou, Yang; Zhou, Weimin; Matthews, Thomas P.; Appleton, Catherine M.; Anastasio, Mark A.
2017-04-01
Photoacoustic computed tomography (PACT) and ultrasound computed tomography (USCT) are emerging modalities for breast imaging. As in all emerging imaging technologies, computer-simulation studies play a critically important role in developing and optimizing the designs of hardware and image reconstruction methods for PACT and USCT. Using computer-simulations, the parameters of an imaging system can be systematically and comprehensively explored in a way that is generally not possible through experimentation. When conducting such studies, numerical phantoms are employed to represent the physical properties of the patient or object to-be-imaged that influence the measured image data. It is highly desirable to utilize numerical phantoms that are realistic, especially when task-based measures of image quality are to be utilized to guide system design. However, most reported computer-simulation studies of PACT and USCT breast imaging employ simple numerical phantoms that oversimplify the complex anatomical structures in the human female breast. We develop and implement a methodology for generating anatomically realistic numerical breast phantoms from clinical contrast-enhanced magnetic resonance imaging data. The phantoms will depict vascular structures and the volumetric distribution of different tissue types in the breast. By assigning optical and acoustic parameters to different tissue structures, both optical and acoustic breast phantoms will be established for use in PACT and USCT studies.
Applicability of active infrared thermography for screening of human breast: a numerical study
NASA Astrophysics Data System (ADS)
Dua, Geetika; Mulaveesala, Ravibabu
2018-03-01
Active infrared thermography is a fast, painless, noncontact, and noninvasive imaging method, complementary to mammography, ultrasound, and magnetic resonance imaging methods for early diagnosis of breast cancer. This technique plays an important role in early detection of breast cancer to women of all ages, including pregnant or nursing women, with different sizes of breast, irrespective of either fatty or dense breast. This proposed complementary technique makes use of infrared emission emanating from the breast. Emanating radiations from the surface of the breast under test are detected with an infrared camera to map the thermal gradients over it, in order to reveal hidden tumors inside it. One of the reliable active infrared thermographic technique, linear frequency modulated thermal wave imaging is adopted to detect tumors present inside the breast. Further, phase and amplitude images are constructed using frequency and time-domain data analysis schemes. Obtained results show the potential of the proposed technique for early diagnosis of breast cancer in fatty as well as dense breasts.
Breast compression in mammography: how much is enough?
Poulos, Ann; McLean, Donald; Rickard, Mary; Heard, Robert
2003-06-01
The amount of breast compression that is applied during mammography potentially influences image quality and the discomfort experienced. The aim of this study was to determine the relationship between applied compression force, breast thickness, reported discomfort and image quality. Participants were women attending routine breast screening by mammography at BreastScreen New South Wales Central and Eastern Sydney. During the mammographic procedure, an 'extra' craniocaudal (CC) film was taken at a reduced level of compression ranging from 10 to 30 Newtons. Breast thickness measurements were recorded for both the normal and the extra CC film. Details of discomfort experienced, cup size, menstrual status, existing breast pain and breast problems were also recorded. Radiologists were asked to compare the image quality of the normal and manipulated film. The results indicated that 24% of women did not experience a difference in thickness when the compression was reduced. This is an important new finding because the aim of breast compression is to reduce breast thickness. If breast thickness is not reduced when compression force is applied then discomfort is increased with no benefit in image quality. This has implications for mammographic practice when determining how much breast compression is sufficient. Radiologists found a decrease in contrast resolution within the fatty area of the breast between the normal and the extra CC film, confirming a decrease in image quality due to insufficient applied compression force.
Czwoydzinski, J; Girnus, R; Sommer, A; Heindel, W; Lenzen, H
2011-09-01
Physical-technical quality assurance is one of the essential tasks of the National Reference Centers in the German Breast Cancer Screening Program. For this purpose the mammography units are required to transfer the measured values of the constancy tests on a daily basis and all phantom images created for this purpose on a weekly basis to the reference centers. This is a serious logistical challenge. To meet these requirements, we developed an innovative software tool. By the end of 2005, we had already developed web-based software (MammoControl) allowing the transmission of constancy test results via entry forms. For automatic analysis and transmission of the phantom images, we then introduced an extension (MammoControl DIANA). This was based on Java, Java Web Start, the NetBeans Rich Client Platform, the Pixelmed Java DICOM Toolkit and the ImageJ library. MammoControl DIANA was designed to run locally in the mammography units. This allows automated on-site image analysis. Both results and compressed images can then be transmitted to the reference center. We developed analysis modules for the daily and monthly consistency tests and additionally for a homogeneity test. The software we developed facilitates the immediate availability of measurement results, phantom images, and DICOM header data in all reference centers. This allows both targeted guidance and short response time in the case of errors. We achieved a consistent IT-based evaluation with standardized tools for the entire screening program in Germany. © Georg Thieme Verlag KG Stuttgart · New York.
NASA Astrophysics Data System (ADS)
Elangovan, Premkumar; Mackenzie, Alistair; Dance, David R.; Young, Kenneth C.; Cooke, Victoria; Wilkinson, Louise; Given-Wilson, Rosalind M.; Wallis, Matthew G.; Wells, Kevin
2017-04-01
A novel method has been developed for generating quasi-realistic voxel phantoms which simulate the compressed breast in mammography and digital breast tomosynthesis (DBT). The models are suitable for use in virtual clinical trials requiring realistic anatomy which use the multiple alternative forced choice (AFC) paradigm and patches from the complete breast image. The breast models are produced by extracting features of breast tissue components from DBT clinical images including skin, adipose and fibro-glandular tissue, blood vessels and Cooper’s ligaments. A range of different breast models can then be generated by combining these components. Visual realism was validated using a receiver operating characteristic (ROC) study of patches from simulated images calculated using the breast models and from real patient images. Quantitative analysis was undertaken using fractal dimension and power spectrum analysis. The average areas under the ROC curves for 2D and DBT images were 0.51 ± 0.06 and 0.54 ± 0.09 demonstrating that simulated and real images were statistically indistinguishable by expert breast readers (7 observers); errors represented as one standard error of the mean. The average fractal dimensions (2D, DBT) for real and simulated images were (2.72 ± 0.01, 2.75 ± 0.01) and (2.77 ± 0.03, 2.82 ± 0.04) respectively; errors represented as one standard error of the mean. Excellent agreement was found between power spectrum curves of real and simulated images, with average β values (2D, DBT) of (3.10 ± 0.17, 3.21 ± 0.11) and (3.01 ± 0.32, 3.19 ± 0.07) respectively; errors represented as one standard error of the mean. These results demonstrate that radiological images of these breast models realistically represent the complexity of real breast structures and can be used to simulate patches from mammograms and DBT images that are indistinguishable from patches from the corresponding real breast images. The method can generate about 500 radiological patches (~30 mm × 30 mm) per day for AFC experiments on a single workstation. This is the first study to quantitatively validate the realism of simulated radiological breast images using direct blinded comparison with real data via the ROC paradigm with expert breast readers.
Brück, N; Koskivuo, I; Boström, P; Saunavaara, J; Aaltonen, R; Parkkola, R
2018-03-01
Preoperative magnetic resonance imaging has become an important complementary imaging technique in patients with breast cancer, providing additional information for preoperative local staging. Magnetic resonance imaging is recommended selectively in lobular breast cancer and in patients with dense breast tissue in the case when mammography and ultrasound fail to fully evaluate the lesion, but the routine use of magnetic resonance imaging in all patients with invasive ductal carcinoma is controversial. The purpose of this randomized study was to investigate the diagnostic value of preoperative magnetic resonance imaging and its impact on short-term surgical outcome in newly diagnosed unifocal stage I invasive ductal carcinoma. A total of 100 patients were randomized to either receive preoperative breast magnetic resonance imaging or to be scheduled directly to operation without magnetic resonance imaging on a 1:1 basis. There were 50 patients in both study arms. In 14 patients (28%), breast magnetic resonance imaging detected an additional finding and seven of them were found to be malignant. Six additional cancer foci were found in the ipsilateral breast and one in the contralateral breast. Magnetic resonance imaging findings caused a change in planned surgical management in 10 patients (20%). Mastectomy was performed in six patients (12%) in the magnetic resonance imaging group and in two patients (4%) in the control group ( p = 0.140). The breast reoperation rate was 14% in the magnetic resonance imaging group and 24% in the control group ( p = 0.202). The mean interval between referral and first surgical procedure was 34 days in the magnetic resonance imaging group and 21 days in the control group ( p < 0.001). Preoperative magnetic resonance imaging may be beneficial for some patients with early-stage invasive ductal carcinoma, but its routine use is not recommended without specific indications.
Breast histopathology image segmentation using spatio-colour-texture based graph partition method.
Belsare, A D; Mushrif, M M; Pangarkar, M A; Meshram, N
2016-06-01
This paper proposes a novel integrated spatio-colour-texture based graph partitioning method for segmentation of nuclear arrangement in tubules with a lumen or in solid islands without a lumen from digitized Hematoxylin-Eosin stained breast histology images, in order to automate the process of histology breast image analysis to assist the pathologists. We propose a new similarity based super pixel generation method and integrate it with texton representation to form spatio-colour-texture map of Breast Histology Image. Then a new weighted distance based similarity measure is used for generation of graph and final segmentation using normalized cuts method is obtained. The extensive experiments carried shows that the proposed algorithm can segment nuclear arrangement in normal as well as malignant duct in breast histology tissue image. For evaluation of the proposed method the ground-truth image database of 100 malignant and nonmalignant breast histology images is created with the help of two expert pathologists and the quantitative evaluation of proposed breast histology image segmentation has been performed. It shows that the proposed method outperforms over other methods. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Keller, Brad M.; Nathan, Diane L.; Wang Yan
Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., 'FOR PROCESSING') andmore » vendor postprocessed (i.e., 'FOR PRESENTATION'), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which are then aggregated into a final dense tissue segmentation that is used to compute breast PD%. Our method is validated on a group of 81 women for whom bilateral, mediolateral oblique, raw and processed screening digital mammograms were available, and agreement is assessed with both continuous and categorical density estimates made by a trained breast-imaging radiologist. Results: Strong association between algorithm-estimated and radiologist-provided breast PD% was detected for both raw (r= 0.82, p < 0.001) and processed (r= 0.85, p < 0.001) digital mammograms on a per-breast basis. Stronger agreement was found when overall breast density was assessed on a per-woman basis for both raw (r= 0.85, p < 0.001) and processed (0.89, p < 0.001) mammograms. Strong agreement between categorical density estimates was also seen (weighted Cohen's {kappa}{>=} 0.79). Repeated measures analysis of variance demonstrated no statistically significant differences between the PD% estimates (p > 0.1) due to either presentation of the image (raw vs processed) or method of PD% assessment (radiologist vs algorithm). Conclusions: The proposed fully automated algorithm was successful in estimating breast percent density from both raw and processed digital mammographic images. Accurate assessment of a woman's breast density is critical in order for the estimate to be incorporated into risk assessment models. These results show promise for the clinical application of the algorithm in quantifying breast density in a repeatable manner, both at time of imaging as well as in retrospective studies.« less
Keller, Brad M.; Nathan, Diane L.; Wang, Yan; Zheng, Yuanjie; Gee, James C.; Conant, Emily F.; Kontos, Despina
2012-01-01
Purpose: The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., “FOR PROCESSING”) and vendor postprocessed (i.e., “FOR PRESENTATION”), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. Methods: This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which are then aggregated into a final dense tissue segmentation that is used to compute breast PD%. Our method is validated on a group of 81 women for whom bilateral, mediolateral oblique, raw and processed screening digital mammograms were available, and agreement is assessed with both continuous and categorical density estimates made by a trained breast-imaging radiologist. Results: Strong association between algorithm-estimated and radiologist-provided breast PD% was detected for both raw (r = 0.82, p < 0.001) and processed (r = 0.85, p < 0.001) digital mammograms on a per-breast basis. Stronger agreement was found when overall breast density was assessed on a per-woman basis for both raw (r = 0.85, p < 0.001) and processed (0.89, p < 0.001) mammograms. Strong agreement between categorical density estimates was also seen (weighted Cohen's κ ≥ 0.79). Repeated measures analysis of variance demonstrated no statistically significant differences between the PD% estimates (p > 0.1) due to either presentation of the image (raw vs processed) or method of PD% assessment (radiologist vs algorithm). Conclusions: The proposed fully automated algorithm was successful in estimating breast percent density from both raw and processed digital mammographic images. Accurate assessment of a woman's breast density is critical in order for the estimate to be incorporated into risk assessment models. These results show promise for the clinical application of the algorithm in quantifying breast density in a repeatable manner, both at time of imaging as well as in retrospective studies. PMID:22894417
Keller, Brad M; Nathan, Diane L; Wang, Yan; Zheng, Yuanjie; Gee, James C; Conant, Emily F; Kontos, Despina
2012-08-01
The amount of fibroglandular tissue content in the breast as estimated mammographically, commonly referred to as breast percent density (PD%), is one of the most significant risk factors for developing breast cancer. Approaches to quantify breast density commonly focus on either semiautomated methods or visual assessment, both of which are highly subjective. Furthermore, most studies published to date investigating computer-aided assessment of breast PD% have been performed using digitized screen-film mammograms, while digital mammography is increasingly replacing screen-film mammography in breast cancer screening protocols. Digital mammography imaging generates two types of images for analysis, raw (i.e., "FOR PROCESSING") and vendor postprocessed (i.e., "FOR PRESENTATION"), of which postprocessed images are commonly used in clinical practice. Development of an algorithm which effectively estimates breast PD% in both raw and postprocessed digital mammography images would be beneficial in terms of direct clinical application and retrospective analysis. This work proposes a new algorithm for fully automated quantification of breast PD% based on adaptive multiclass fuzzy c-means (FCM) clustering and support vector machine (SVM) classification, optimized for the imaging characteristics of both raw and processed digital mammography images as well as for individual patient and image characteristics. Our algorithm first delineates the breast region within the mammogram via an automated thresholding scheme to identify background air followed by a straight line Hough transform to extract the pectoral muscle region. The algorithm then applies adaptive FCM clustering based on an optimal number of clusters derived from image properties of the specific mammogram to subdivide the breast into regions of similar gray-level intensity. Finally, a SVM classifier is trained to identify which clusters within the breast tissue are likely fibroglandular, which are then aggregated into a final dense tissue segmentation that is used to compute breast PD%. Our method is validated on a group of 81 women for whom bilateral, mediolateral oblique, raw and processed screening digital mammograms were available, and agreement is assessed with both continuous and categorical density estimates made by a trained breast-imaging radiologist. Strong association between algorithm-estimated and radiologist-provided breast PD% was detected for both raw (r = 0.82, p < 0.001) and processed (r = 0.85, p < 0.001) digital mammograms on a per-breast basis. Stronger agreement was found when overall breast density was assessed on a per-woman basis for both raw (r = 0.85, p < 0.001) and processed (0.89, p < 0.001) mammograms. Strong agreement between categorical density estimates was also seen (weighted Cohen's κ ≥ 0.79). Repeated measures analysis of variance demonstrated no statistically significant differences between the PD% estimates (p > 0.1) due to either presentation of the image (raw vs processed) or method of PD% assessment (radiologist vs algorithm). The proposed fully automated algorithm was successful in estimating breast percent density from both raw and processed digital mammographic images. Accurate assessment of a woman's breast density is critical in order for the estimate to be incorporated into risk assessment models. These results show promise for the clinical application of the algorithm in quantifying breast density in a repeatable manner, both at time of imaging as well as in retrospective studies.
Hooley, Regina J; Andrejeva, Liva; Scoutt, Leslie M
2011-03-01
Although mammography is the mainstay of early breast cancer detection, it has known limitations, particularly in women with dense breasts. As a result, additional imaging modalities, including ultrasound and contrast-enhanced magnetic resonance imaging, are also being used to supplement mammography in the early detection of occult breast cancer. This article reviews the indications and efficacy of mammography, ultrasound, and magnetic resonance imaging as both screening and diagnostic tools.
Breast percent density estimation from 3D reconstructed digital breast tomosynthesis images
NASA Astrophysics Data System (ADS)
Bakic, Predrag R.; Kontos, Despina; Carton, Ann-Katherine; Maidment, Andrew D. A.
2008-03-01
Breast density is an independent factor of breast cancer risk. In mammograms breast density is quantitatively measured as percent density (PD), the percentage of dense (non-fatty) tissue. To date, clinical estimates of PD have varied significantly, in part due to the projective nature of mammography. Digital breast tomosynthesis (DBT) is a 3D imaging modality in which cross-sectional images are reconstructed from a small number of projections acquired at different x-ray tube angles. Preliminary studies suggest that DBT is superior to mammography in tissue visualization, since superimposed anatomical structures present in mammograms are filtered out. We hypothesize that DBT could also provide a more accurate breast density estimation. In this paper, we propose to estimate PD from reconstructed DBT images using a semi-automated thresholding technique. Preprocessing is performed to exclude the image background and the area of the pectoral muscle. Threshold values are selected manually from a small number of reconstructed slices; a combination of these thresholds is applied to each slice throughout the entire reconstructed DBT volume. The proposed method was validated using images of women with recently detected abnormalities or with biopsy-proven cancers; only contralateral breasts were analyzed. The Pearson correlation and kappa coefficients between the breast density estimates from DBT and the corresponding digital mammogram indicate moderate agreement between the two modalities, comparable with our previous results from 2D DBT projections. Percent density appears to be a robust measure for breast density assessment in both 2D and 3D x-ray breast imaging modalities using thresholding.
Computerized image analysis: estimation of breast density on mammograms
NASA Astrophysics Data System (ADS)
Zhou, Chuan; Chan, Heang-Ping; Petrick, Nicholas; Sahiner, Berkman; Helvie, Mark A.; Roubidoux, Marilyn A.; Hadjiiski, Lubomir M.; Goodsitt, Mitchell M.
2000-06-01
An automated image analysis tool is being developed for estimation of mammographic breast density, which may be useful for risk estimation or for monitoring breast density change in a prevention or intervention program. A mammogram is digitized using a laser scanner and the resolution is reduced to a pixel size of 0.8 mm X 0.8 mm. Breast density analysis is performed in three stages. First, the breast region is segmented from the surrounding background by an automated breast boundary-tracking algorithm. Second, an adaptive dynamic range compression technique is applied to the breast image to reduce the range of the gray level distribution in the low frequency background and to enhance the differences in the characteristic features of the gray level histogram for breasts of different densities. Third, rule-based classification is used to classify the breast images into several classes according to the characteristic features of their gray level histogram. For each image, a gray level threshold is automatically determined to segment the dense tissue from the breast region. The area of segmented dense tissue as a percentage of the breast area is then estimated. In this preliminary study, we analyzed the interobserver variation of breast density estimation by two experienced radiologists using BI-RADS lexicon. The radiologists' visually estimated percent breast densities were compared with the computer's calculation. The results demonstrate the feasibility of estimating mammographic breast density using computer vision techniques and its potential to improve the accuracy and reproducibility in comparison with the subjective visual assessment by radiologists.
Bickelhaupt, Sebastian; Paech, Daniel; Kickingereder, Philipp; Steudle, Franziska; Lederer, Wolfgang; Daniel, Heidi; Götz, Michael; Gählert, Nils; Tichy, Diana; Wiesenfarth, Manuel; Laun, Frederik B; Maier-Hein, Klaus H; Schlemmer, Heinz-Peter; Bonekamp, David
2017-08-01
To assess radiomics as a tool to determine how well lesions found suspicious on breast cancer screening X-ray mammography can be categorized into malignant and benign with unenhanced magnetic resonance (MR) mammography with diffusion-weighted imaging and T 2 -weighted sequences. From an asymptomatic screening cohort, 50 women with mammographically suspicious findings were examined with contrast-enhanced breast MRI (ceMRI) at 1.5T. Out of this protocol an unenhanced, abbreviated diffusion-weighted imaging protocol (ueMRI) including T 2 -weighted, (T 2 w), diffusion-weighted imaging (DWI), and DWI with background suppression (DWIBS) sequences and corresponding apparent diffusion coefficient (ADC) maps were extracted. From ueMRI-derived radiomic features, three Lasso-supervised machine-learning classifiers were constructed and compared with the clinical performance of a highly experienced radiologist: 1) univariate mean ADC model, 2) unconstrained radiomic model, 3) constrained radiomic model with mandatory inclusion of mean ADC. The unconstrained and constrained radiomic classifiers consisted of 11 parameters each and achieved differentiation of malignant from benign lesions with a .632 + bootstrap receiver operating characteristics (ROC) area under the curve (AUC) of 84.2%/85.1%, compared to 77.4% for mean ADC and 95.9%/95.9% for the experienced radiologist using ceMRI/ueMRI. In this pilot study we identified two ueMRI radiomics classifiers that performed well in the differentiation of malignant from benign lesions and achieved higher performance than the mean ADC parameter alone. Classification was lower than the almost perfect performance of a highly experienced breast radiologist. The potential of radiomics to provide a training-independent diagnostic decision tool is indicated. A performance reaching the human expert would be highly desirable and based on our results is considered possible when the concept is extended in larger cohorts with further development and validation of the technique. 1 Technical Efficacy: Stage 2 J. MAGN. RESON. IMAGING 2017;46:604-616. © 2017 International Society for Magnetic Resonance in Medicine.
An object-oriented simulator for 3D digital breast tomosynthesis imaging system.
Seyyedi, Saeed; Cengiz, Kubra; Kamasak, Mustafa; Yildirim, Isa
2013-01-01
Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values.
An Object-Oriented Simulator for 3D Digital Breast Tomosynthesis Imaging System
Cengiz, Kubra
2013-01-01
Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values. PMID:24371468
Dontchos, Brian N.; Partridge, Savannah C.; Korde, Larissa A.; Lam, Diana L.; Scheel, John R.; Peacock, Sue; Lehman, Constance D.
2015-01-01
Purpose To investigate whether qualitative magnetic resonance (MR) imaging assessments of background parenchymal enhancement (BPE), amount of fibroglandular tissue (FGT), and mammographic density are associated with risk of developing breast cancer in women who are at high risk. Materials and Methods In this institutional review board–approved HIPAA-compliant retrospective study, all screening breast MR images obtained from January 2006 to December 2011 in women aged 18 years or older and at high risk for but without a history of breast cancer were identified. Women in whom breast cancer was diagnosed after index MR imaging comprised the cancer cohort, and one-to-one matching (age and BRCA status) of each woman with breast cancer to a control subject was performed by using MR images obtained in women who did not develop breast cancer with follow-up time maximized. Amount of BPE, BPE pattern (peripheral vs central), amount of FGT at MR imaging, and mammographic density were assessed on index images. Imaging features were compared between cancer and control cohorts by using conditional logistic regression. Results Twenty-three women at high risk (mean age, 47 years ± 10 [standard deviation]; six women had BRCA mutations) with no history of breast cancer underwent screening breast MR imaging; in these women, a diagnosis of breast cancer (invasive, n = 12; in situ, n = 11) was made during the follow-up interval. Women with mild, moderate, or marked BPE were nine times more likely to receive a diagnosis of breast cancer during the follow-up interval than were those with minimal BPE (P = .007; odds ratio = 9.0; 95% confidence interval: 1.1, 71.0). BPE pattern, MR imaging amount of FGT, and mammographic density were not significantly different between the cohorts (P = .5, P = .5, and P = .4, respectively). Conclusion Greater BPE was associated with a higher probability of developing breast cancer in women at high risk for cancer and warrants further study. © RSNA, 2015 Online supplemental material is available for this article. PMID:25965809
NASA Astrophysics Data System (ADS)
Aghaei, Faranak; Tan, Maxine; Hollingsworth, Alan B.; Zheng, Bin; Cheng, Samuel
2016-03-01
Dynamic contrast-enhanced breast magnetic resonance imaging (DCE-MRI) has been used increasingly in breast cancer diagnosis and assessment of cancer treatment efficacy. In this study, we applied a computer-aided detection (CAD) scheme to automatically segment breast regions depicting on MR images and used the kinetic image features computed from the global breast MR images acquired before neoadjuvant chemotherapy to build a new quantitative model to predict response of the breast cancer patients to the chemotherapy. To assess performance and robustness of this new prediction model, an image dataset involving breast MR images acquired from 151 cancer patients before undergoing neoadjuvant chemotherapy was retrospectively assembled and used. Among them, 63 patients had "complete response" (CR) to chemotherapy in which the enhanced contrast levels inside the tumor volume (pre-treatment) was reduced to the level as the normal enhanced background parenchymal tissues (post-treatment), while 88 patients had "partially response" (PR) in which the high contrast enhancement remain in the tumor regions after treatment. We performed the studies to analyze the correlation among the 22 global kinetic image features and then select a set of 4 optimal features. Applying an artificial neural network trained with the fusion of these 4 kinetic image features, the prediction model yielded an area under ROC curve (AUC) of 0.83+/-0.04. This study demonstrated that by avoiding tumor segmentation, which is often difficult and unreliable, fusion of kinetic image features computed from global breast MR images without tumor segmentation can also generate a useful clinical marker in predicting efficacy of chemotherapy.
Chae, Michael P; Rozen, Warren Matthew; Patel, Nakul Gamanlal; Hunter-Smith, David J; Ramakrishnan, Venkat
2017-12-01
An increasing number of women undergo mastectomy for breast cancer and post-mastectomy autologous breast reconstruction has been shown to significantly improve the psychosexual wellbeing of the patients. A goal of treatment is to achieve symmetry and projection to match the native breast, and/or the contralateral breast in the case of a unilateral reconstruction. Autologous reconstruction, particularly with the deep inferior epigastric artery perforator (DIEP) flap, is particularly advantageous as it can be manipulated to mimic the shape and turgor of the native breast. However, very few techniques of shaping the breast conus when insetting the DIEP flap to enhance aesthetic outcome have been reported to date. With the aide of three-dimension (3D) photography and 3D-printed mirrored image of the contralateral breast as a guide intraoperatively, we describe our St Andrew's coning technique to create a personalized flap projection. We report a prospective case series of 3 delayed unilateral breast reconstructions where symmetrization procedure to the contralateral breast was not indicated. Using a commercial 3D scanner (VECTRA XR, Canfield Scientific), the breast region was imaged. The mirrored image was 3D-printed in-house using a desktop 3D printer. In all cases, projection of the breast mound was able to be safely achieved, with a demonstrated central volume (or 'cone') able to be highlighted on imaging and a 3D printed breast. A 3D print of the contralateral breast was able to be used intraoperatively to guide the operative approach. The St Andrew's coning technique is a useful aesthetic maneuver for achieving breast projection during DIEP flap breast reconstruction, with 3D imaging techniques able to assist in perioperative assessment of breast volume.
Chae, Michael P.; Patel, Nakul Gamanlal; Hunter-Smith, David J.; Ramakrishnan, Venkat
2017-01-01
Background An increasing number of women undergo mastectomy for breast cancer and post-mastectomy autologous breast reconstruction has been shown to significantly improve the psychosexual wellbeing of the patients. A goal of treatment is to achieve symmetry and projection to match the native breast, and/or the contralateral breast in the case of a unilateral reconstruction. Autologous reconstruction, particularly with the deep inferior epigastric artery perforator (DIEP) flap, is particularly advantageous as it can be manipulated to mimic the shape and turgor of the native breast. However, very few techniques of shaping the breast conus when insetting the DIEP flap to enhance aesthetic outcome have been reported to date. With the aide of three-dimension (3D) photography and 3D-printed mirrored image of the contralateral breast as a guide intraoperatively, we describe our St Andrew’s coning technique to create a personalized flap projection. Method We report a prospective case series of 3 delayed unilateral breast reconstructions where symmetrization procedure to the contralateral breast was not indicated. Using a commercial 3D scanner (VECTRA XR, Canfield Scientific), the breast region was imaged. The mirrored image was 3D-printed in-house using a desktop 3D printer. Results In all cases, projection of the breast mound was able to be safely achieved, with a demonstrated central volume (or ‘cone’) able to be highlighted on imaging and a 3D printed breast. A 3D print of the contralateral breast was able to be used intraoperatively to guide the operative approach. Conclusions The St Andrew’s coning technique is a useful aesthetic maneuver for achieving breast projection during DIEP flap breast reconstruction, with 3D imaging techniques able to assist in perioperative assessment of breast volume. PMID:29302489
Lee, Su Hyun; Chang, Jung Min; Shin, Sung Ui; Chu, A Jung; Yi, Ann; Cho, Nariya; Moon, Woo Kyung
2017-12-01
To evaluate imaging features of breast cancers on digital breast tomosynthesis (DBT) according to molecular subtype and to determine whether the molecular subtype affects breast cancer detection on DBT. This was an institutional review board--approved study with a waiver of informed consent. DBT findings of 288 invasive breast cancers were reviewed according to Breast Imaging Reporting and Data System lexicon. Detectability of breast cancer was quantified by the number of readers (0-3) who correctly detected the cancer in an independent blinded review. DBT features and the cancer detectability score according to molecular subtype were compared using Fisher's exact test and analysis of variance. Of 288 invasive cancers, 194 were hormone receptor (HR)-positive, 48 were human epidermal growth factor receptor 2 (HER2) positive and 46 were triple negative breast cancers. The most common DBT findings were irregular spiculated masses for HR-positive cancer, fine pleomorphic or linear branching calcifications for HER2 positive cancer and irregular masses with circumscribed margins for triple negative breast cancers (p < 0.001). Cancer detectability on DBT was not significantly different according to molecular subtype (p = 0.213) but rather affected by tumour size, breast density and presence of mass or calcifications. Breast cancers showed different imaging features according to molecular subtype; however, it did not affect the cancer detectability on DBT. Advances in knowledge: DBT showed characteristic imaging features of breast cancers according to molecular subtype. However, cancer detectability on DBT was not affected by molecular subtype of breast cancers.
Niell, Bethany L; Freer, Phoebe E; Weinfurtner, Robert Jared; Arleo, Elizabeth Kagan; Drukteinis, Jennifer S
2017-11-01
The goal of screening is to detect breast cancers when still curable to decrease breast cancer-specific mortality. Breast cancer screening in the United States is routinely performed with mammography, supplemental digital breast tomosynthesis, ultrasound, and/or MR imaging. This article aims to review the most commonly used breast imaging modalities for screening, discuss how often and when to begin screening with specific imaging modalities, and examine the pros and cons of screening. By the article's end, the reader will be better equipped to have informed discussions with patients and medical professionals regarding the benefits and disadvantages of breast cancer screening. Copyright © 2017 Elsevier Inc. All rights reserved.
Dose reduction in molecular breast imaging
NASA Astrophysics Data System (ADS)
Wagenaar, Douglas J.; Chowdhury, Samir; Hugg, James W.; Moats, Rex A.; Patt, Bradley E.
2011-10-01
Molecular Breast Imaging (MBI) is the imaging of radiolabeled drugs, cells, or nanoparticles for breast cancer detection, diagnosis, and treatment. Screening of broad populations of women for breast cancer with mammography has been augmented by the emergence of breast MRI in screening of women at high risk for breast cancer. Screening MBI may benefit the sub-population of women with dense breast tissue that obscures small tumors in mammography. Dedicated breast imaging equipment is necessary to enable detection of early-stage tumors less than 1 cm in size. Recent progress in the development of these instruments is reviewed. Pixellated CZT for single photon MBI imaging of 99mTc-sestamibi gives high detection sensitivity for early-stage tumors. The use of registered collimators in a near-field geometry gives significantly higher detection efficiency - a factor of 3.6-, which translates into an equivalent dose reduction factor given the same acquisition time. The radiation dose in the current MBI procedure has been reduced to the level of a four-view digital mammography study. In addition to screening of selected sub-populations, reduced MBI dose allows for dual-isotope, treatment planning, and repeated therapy assessment studies in the era of molecular medicine guided by quantitative molecular imaging.
Computer-aided, multi-modal, and compression diffuse optical studies of breast tissue
NASA Astrophysics Data System (ADS)
Busch, David Richard, Jr.
Diffuse Optical Tomography and Spectroscopy permit measurement of important physiological parameters non-invasively through ˜10 cm of tissue. I have applied these techniques in measurements of human breast and breast cancer. My thesis integrates three loosely connected themes in this context: multi-modal breast cancer imaging, automated data analysis of breast cancer images, and microvascular hemodynamics of breast under compression. As per the first theme, I describe construction, testing, and the initial clinical usage of two generations of imaging systems for simultaneous diffuse optical and magnetic resonance imaging. The second project develops a statistical analysis of optical breast data from many spatial locations in a population of cancers to derive a novel optical signature of malignancy; I then apply this data-derived signature for localization of cancer in additional subjects. Finally, I construct and deploy diffuse optical instrumentation to measure blood content and blood flow during breast compression; besides optics, this research has implications for any method employing breast compression, e.g., mammography.
A deep learning method for classifying mammographic breast density categories.
Mohamed, Aly A; Berg, Wendie A; Peng, Hong; Luo, Yahong; Jankowitz, Rachel C; Wu, Shandong
2018-01-01
Mammographic breast density is an established risk marker for breast cancer and is visually assessed by radiologists in routine mammogram image reading, using four qualitative Breast Imaging and Reporting Data System (BI-RADS) breast density categories. It is particularly difficult for radiologists to consistently distinguish the two most common and most variably assigned BI-RADS categories, i.e., "scattered density" and "heterogeneously dense". The aim of this work was to investigate a deep learning-based breast density classifier to consistently distinguish these two categories, aiming at providing a potential computerized tool to assist radiologists in assigning a BI-RADS category in current clinical workflow. In this study, we constructed a convolutional neural network (CNN)-based model coupled with a large (i.e., 22,000 images) digital mammogram imaging dataset to evaluate the classification performance between the two aforementioned breast density categories. All images were collected from a cohort of 1,427 women who underwent standard digital mammography screening from 2005 to 2016 at our institution. The truths of the density categories were based on standard clinical assessment made by board-certified breast imaging radiologists. Effects of direct training from scratch solely using digital mammogram images and transfer learning of a pretrained model on a large nonmedical imaging dataset were evaluated for the specific task of breast density classification. In order to measure the classification performance, the CNN classifier was also tested on a refined version of the mammogram image dataset by removing some potentially inaccurately labeled images. Receiver operating characteristic (ROC) curves and the area under the curve (AUC) were used to measure the accuracy of the classifier. The AUC was 0.9421 when the CNN-model was trained from scratch on our own mammogram images, and the accuracy increased gradually along with an increased size of training samples. Using the pretrained model followed by a fine-tuning process with as few as 500 mammogram images led to an AUC of 0.9265. After removing the potentially inaccurately labeled images, AUC was increased to 0.9882 and 0.9857 for without and with the pretrained model, respectively, both significantly higher (P < 0.001) than when using the full imaging dataset. Our study demonstrated high classification accuracies between two difficult to distinguish breast density categories that are routinely assessed by radiologists. We anticipate that our approach will help enhance current clinical assessment of breast density and better support consistent density notification to patients in breast cancer screening. © 2017 American Association of Physicists in Medicine.
Dobbs, Jessica; Krishnamurthy, Savitri; Kyrish, Matthew; Benveniste, Ana Paula; Yang, Wei; Richards-Kortum, Rebecca
2015-01-01
Tissue sampling is a problematic issue for inflammatory breast carcinoma, and immediate evaluation following core needle biopsy is needed to evaluate specimen adequacy. We sought to determine if confocal fluorescence microscopy provides sufficient resolution to evaluate specimen adequacy by comparing invasive tumor cellularity estimated from standard histologic images to invasive tumor cellularity estimated from confocal images of breast core needle biopsy specimens. Grayscale confocal fluorescence images of breast core needle biopsy specimens were acquired following proflavine application. A breast-dedicated pathologist evaluated invasive tumor cellularity in histologic images with hematoxylin and eosin staining and in grayscale and false-colored confocal images of cores. Agreement between cellularity estimates was quantified using a kappa coefficient. 23 cores from 23 patients with suspected inflammatory breast carcinoma were imaged. Confocal images were acquired in an average of less than 2 min per core. Invasive tumor cellularity estimated from histologic and grayscale confocal images showed moderate agreement by kappa coefficient: κ = 0.48 ± 0.09 (p < 0.001). Grayscale confocal images require less than 2 min for acquisition and allow for evaluation of invasive tumor cellularity in breast core needle biopsy specimens with moderate agreement to histologic images. We show that confocal fluorescence microscopy can be performed immediately following specimen acquisition and could indicate the need for additional biopsies at the initial visit.
2D and 3D registration methods for dual-energy contrast-enhanced digital breast tomosynthesis
NASA Astrophysics Data System (ADS)
Lau, Kristen C.; Roth, Susan; Maidment, Andrew D. A.
2014-03-01
Contrast-enhanced digital breast tomosynthesis (CE-DBT) uses an iodinated contrast agent to image the threedimensional breast vasculature. The University of Pennsylvania is conducting a CE-DBT clinical study in patients with known breast cancers. The breast is compressed continuously and imaged at four time points (1 pre-contrast; 3 postcontrast). A hybrid subtraction scheme is proposed. First, dual-energy (DE) images are obtained by a weighted logarithmic subtraction of the high-energy and low-energy image pairs. Then, post-contrast DE images are subtracted from the pre-contrast DE image. This hybrid temporal subtraction of DE images is performed to analyze iodine uptake, but suffers from motion artifacts. Employing image registration further helps to correct for motion, enhancing the evaluation of vascular kinetics. Registration using ANTS (Advanced Normalization Tools) is performed in an iterative manner. Mutual information optimization first corrects large-scale motions. Normalized cross-correlation optimization then iteratively corrects fine-scale misalignment. Two methods have been evaluated: a 2D method using a slice-by-slice approach, and a 3D method using a volumetric approach to account for out-of-plane breast motion. Our results demonstrate that iterative registration qualitatively improves with each iteration (five iterations total). Motion artifacts near the edge of the breast are corrected effectively and structures within the breast (e.g. blood vessels, surgical clip) are better visualized. Statistical and clinical evaluations of registration accuracy in the CE-DBT images are ongoing.
Adherence to Guidelines for Breast Surveillance in Breast Cancer Survivors.
Ruddy, Kathryn J; Sangaralingham, Lindsey; Freedman, Rachel A; Mougalian, Sarah; Neuman, Heather; Greenberg, Caprice; Jemal, Ahmedin; Duma, Narjust; Haddad, Tufia C; Lemaine, Valerie; Ghosh, Karthik; Hieken, Tina J; Hunt, Katie; Vachon, Celine; Gross, Cary; Shah, Nilay D
2018-05-01
Background: Guidelines recommend annual mammography after curative-intent treatment for breast cancer. The goal of this study was to assess contemporary patterns of breast imaging after breast cancer treatment. Methods: Administrative claims data were used to identify privately insured and Medicare Advantage beneficiaries with nonmetastatic breast cancer who had residual breast tissue (not bilateral mastectomy) after breast surgery between January 2005 and May 2015. We calculated the proportion of patients who had a mammogram, MRI, both, or neither during each of 5 subsequent 13-month periods. Multinomial logistic regression was used to assess associations between patient characteristics, healthcare use, and breast imaging in the first and fifth years after surgery. Results: A total of 27,212 patients were followed for a median of 2.9 years (interquartile range, 1.8-4.6) after definitive breast cancer surgery. In year 1, 78% were screened using mammography alone, 1% using MRI alone, and 8% using both tests; 13% did not undergo either. By year 5, the proportion of the remaining cohort (n=4,790) who had no breast imaging was 19%. Older age was associated with an increased likelihood of mammography and a decreased likelihood of MRI during the first and fifth years. Black race, mastectomy, chemotherapy, and no MRI at baseline were all associated with a decreased likelihood of both types of imaging. Conclusions: Even in an insured cohort, a substantial proportion of breast cancer survivors do not undergo annual surveillance breast imaging, particularly as time passes. Understanding factors associated with imaging in cancer survivors may help improve adherence to survivorship care guidelines. Copyright © 2018 by the National Comprehensive Cancer Network.
NASA Astrophysics Data System (ADS)
Zimmermann, Bernhard B.; Deng, Bin; Singh, Bhawana; Martino, Mark; Selb, Juliette; Fang, Qianqian; Sajjadi, Amir Y.; Cormier, Jayne; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.; Saksena, Mansi A.; Carp, Stefan A.
2017-04-01
Diffuse optical tomography (DOT) is emerging as a noninvasive functional imaging method for breast cancer diagnosis and neoadjuvant chemotherapy monitoring. In particular, the multimodal approach of combining DOT with x-ray digital breast tomosynthesis (DBT) is especially synergistic as DBT prior information can be used to enhance the DOT reconstruction. DOT, in turn, provides a functional information overlay onto the mammographic images, increasing sensitivity and specificity to cancer pathology. We describe a dynamic DOT apparatus designed for tight integration with commercial DBT scanners and providing a fast (up to 1 Hz) image acquisition rate to enable tracking hemodynamic changes induced by the mammographic breast compression. The system integrates 96 continuous-wave and 24 frequency-domain source locations as well as 32 continuous wave and 20 frequency-domain detection locations into low-profile plastic plates that can easily mate to the DBT compression paddle and x-ray detector cover, respectively. We demonstrate system performance using static and dynamic tissue-like phantoms as well as in vivo images acquired from the pool of patients recalled for breast biopsies at the Massachusetts General Hospital Breast Imaging Division.
Liquid crystal thermography and true-colour digital image processing
NASA Astrophysics Data System (ADS)
Stasiek, J.; Stasiek, A.; Jewartowski, M.; Collins, M. W.
2006-06-01
In the last decade thermochromic liquid crystals (TLC) and true-colour digital image processing have been successfully used in non-intrusive technical, industrial and biomedical studies and applications. Thin coatings of TLCs at surfaces are utilized to obtain detailed temperature distributions and heat transfer rates for steady or transient processes. Liquid crystals also can be used to make visible the temperature and velocity fields in liquids by the simple expedient of directly mixing the liquid crystal material into the liquid (water, glycerol, glycol, and silicone oils) in very small quantities to use as thermal and hydrodynamic tracers. In biomedical situations e.g., skin diseases, breast cancer, blood circulation and other medical application, TLC and image processing are successfully used as an additional non-invasive diagnostic method especially useful for screening large groups of potential patients. The history of this technique is reviewed, principal methods and tools are described and some examples are also presented.
Shoma, Ashraf M; Mohamed, Madiha H; Nouman, Nashaat; Amin, Mahmoud; Ibrahim, Ibtihal M; Tobar, Salwa S; Gaffar, Hanan E; Aboelez, Warda F; Ali, Salwa E; William, Soheir G
2009-01-01
Background In most developing countries, as in Egypt; postmenopausal breast cancer cases are offered a radical form of surgery relying on their unawareness of the subsequent body image disturbance. This study aimed at evaluating the effect of breast cancer surgical choice; Breast Conservative Therapy (BCT) versus Modified Radical Mastectomy (MRM); on body image perception among Egyptian postmenopausal cases. Methods One hundred postmenopausal women with breast cancer were divided into 2 groups, one group underwent BCT and the other underwent MRM. Pre- and post-operative assessments of body image distress were done using four scales; Breast Impact of Treatment Scale (BITS), Impact of Event Scale (IES), Situational Discomfort Scale (SDS), and Body Satisfaction Scale (BSS). Results Preoperative assessment showed no statistical significant difference regarding cognitive, affective, behavioral and evaluative components of body image between both studied groups. While in postoperative assessment, women in MRM group showed higher levels of body image distress among cognitive, affective and behavioral aspects. Conclusion Body image is an important factor for postmenopausal women with breast cancer in developing countries where that concept is widely ignored. We should not deprive those cases from their right of less mutilating option of treatment as BCT. PMID:19678927
Applicability of active infrared thermography for screening of human breast: a numerical study.
Dua, Geetika; Mulaveesala, Ravibabu
2018-03-01
Active infrared thermography is a fast, painless, noncontact, and noninvasive imaging method, complementary to mammography, ultrasound, and magnetic resonance imaging methods for early diagnosis of breast cancer. This technique plays an important role in early detection of breast cancer to women of all ages, including pregnant or nursing women, with different sizes of breast, irrespective of either fatty or dense breast. This proposed complementary technique makes use of infrared emission emanating from the breast. Emanating radiations from the surface of the breast under test are detected with an infrared camera to map the thermal gradients over it, in order to reveal hidden tumors inside it. One of the reliable active infrared thermographic technique, linear frequency modulated thermal wave imaging is adopted to detect tumors present inside the breast. Further, phase and amplitude images are constructed using frequency and time-domain data analysis schemes. Obtained results show the potential of the proposed technique for early diagnosis of breast cancer in fatty as well as dense breasts. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
Ultrasound of pediatric breast masses: what to do with lumps and bumps.
Valeur, Natalie S; Rahbar, Habib; Chapman, Teresa
2015-10-01
The approach to breast masses in children differs from that in adults in many ways, including the differential diagnostic considerations, imaging algorithm and appropriateness of biopsy as a means of further characterization. Most pediatric breast masses are benign, either related to breast development or benign neoplastic processes. Biopsy is rarely needed and can damage the developing breast; thus radiologists must be familiar with the imaging appearance of common entities so that biopsies are judiciously recommended. The purpose of this article is to describe the imaging appearances of the normally developing pediatric breast as well as illustrate the imaging findings of a spectrum of diseases, including those that are benign (fibroadenoma, juvenile papillomatosis, pseudoangiomatous stromal hyperplasia, gynecomastia, abscess and fat necrosis), malignant (breast carcinoma and metastases), and have variable malignant potential (phyllodes tumor).
Primary breast leiomyosarcoma and synchronous homolateral lung cancer: a case report
Meroni, Stefano; Voulaz, Emanuele; Alloisio, Marco; De Sanctis, Rita; Bossi, Paola; Cariboni, Umberto; De Simone, Matilde; Cioffi, Ugo
2017-01-01
Radiological and histological features of breast leiomyosarcoma can mimic a wide variety of other breast lesions, such as mesenchymal tumors, breast lymphomas, poorly differentiated carcinomas and metaplastic breast carcinomas. The authors present the case of a 62-year-old woman with a primary breast leiomyosarcoma with synchronous ipsilateral lung adenocarcinoma. The latter was an incidental finding during pre-surgical staging examinations. Clinicopathological, immunophenotypic and imaging features cancer are described. A brief review of the literature on imaging findings and management of breast leiomyosarcoma is presented. The authors discuss the differential diagnoses in breast imaging and of the extra-mammary incidental findings. Surgical resection remains the cornerstone of treatment, while radiation therapy and chemotherapy remain to be defined on a single-patient basis. PMID:29312765
Early Breast Cancer Detection by Ultrawide Band Imaging with Dispersion Consideration
NASA Astrophysics Data System (ADS)
Xiao, Xia; Kikkawa, Takamaro
2008-04-01
Ultrawide band (UWB) microwave imaging is a promising method for early-stage breast cancer detection based on the large contrast of electric parameters between the tumor and the normal breast tissue. The tumor can be detected by analyzing the reflection and scattering behavior of the UWB microwave propagating in the breast. In this study, the tumor location is determined by comparing the waveforms resulted from the tumor-containing and tumor-free breasts. The frequency dispersive characteristics of the fatty breast tissue, skin and tumor are considered in the study to approach the actual electrical properties of the breast. The correct location and size are visualized for an early-stage tumor embedded in the breast using the principle of a confocal microwave imaging technique.
Dynamic contrast-enhanced breast MR imaging in men: preliminary results.
Morakkabati-Spitz, Nuschin; Schild, Hans H; Leutner, Claudia C; von Falkenhausen, Marcus; Lutterbey, Götz; Kuhl, Christiane K
2006-02-01
To prospectively evaluate whether the descriptors of lesion features and the diagnostic criteria that have been established for breast magnetic resonance (MR) imaging in female patients may be used for differential diagnosis with breast MR imaging in male patients as well. The study design was approved by the institutional review board; all patients gave informed consent. The Institutional Review Board and informed consent information applied to the prospective and any retrospective component of the study. Seventeen consecutive male patients (mean age, 53 years +/- 14) were referred for imaging of a palpable breast mass. In addition to mammography and high-frequency breast ultrasonography, patients underwent dynamic breast MR imaging in a prone position with a dedicated double-breast surface coil. The standardized protocol consisted of a T2-weighted turbo spin-echo sequence followed by a dynamic series. Findings were recorded by using the terminology and descriptors and by evaluating the diagnostic criteria (related to morphology and enhancement kinetics) that have been developed for breast MR imaging in female patients. Validation was achieved at biopsy (nine patients) or follow-up with clinical examination and conventional imaging (eight patients). Because of the small size of the patient cohort, statistical significance was not tested. A total of 24 breast abnormalities were diagnosed. Three patients had invasive breast cancer (five tumors), 11 had gynecomastia (six unilateral, five bilateral), two had pseudogynecomastia, and one had a benign solid tumor (angiolipoma). All malignant tumors appeared as irregular masses with heterogeneous internal architecture or rim enhancement and showed rapid initial enhancement (mean value, 137% +/- 23) followed by a washout time course (Breast Imaging Reporting and Data System [BI-RADS] category 5). Diffuse and nodular gynecomastia showed slow initial and persistent enhancement with normal-appearing parenchymal architecture (BI-RADS category 2; 15 of 16 breasts in 10 of 11 patients). In one patient with biopsy-proved bilateral gynecomastia, an area with segmental enhancement was classified as suspicious for ductal carcinoma in situ. Pseudogynecomastia did not enhance at all. The angiolipoma showed benign morphologic features and slow initial and persistent enhancement (BI-RADS category 2). In the small study cohort, the MR imaging features of benign breast diseases and breast cancers in male patients seemed to be comparable to those seen in female patients. (c) RSNA, 2005
An interactive method based on the live wire for segmentation of the breast in mammography images.
Zewei, Zhang; Tianyue, Wang; Li, Guo; Tingting, Wang; Lu, Xu
2014-01-01
In order to improve accuracy of computer-aided diagnosis of breast lumps, the authors introduce an improved interactive segmentation method based on Live Wire. This paper presents the Gabor filters and FCM clustering algorithm is introduced to the Live Wire cost function definition. According to the image FCM analysis for image edge enhancement, we eliminate the interference of weak edge and access external features clear segmentation results of breast lumps through improving Live Wire on two cases of breast segmentation data. Compared with the traditional method of image segmentation, experimental results show that the method achieves more accurate segmentation of breast lumps and provides more accurate objective basis on quantitative and qualitative analysis of breast lumps.
NASA Astrophysics Data System (ADS)
Sztrókay, A.; Diemoz, P. C.; Schlossbauer, T.; Brun, E.; Bamberg, F.; Mayr, D.; Reiser, M. F.; Bravin, A.; Coan, P.
2012-05-01
Previous studies on phase contrast imaging (PCI) mammography have demonstrated an enhancement of breast morphology and cancerous tissue visualization compared to conventional imaging. We show here the first results of the PCI analyser-based imaging (ABI) in computed tomography (CT) mode on whole and large (>12 cm) tumour-bearing breast tissues. We demonstrate in this work the capability of the technique of working at high x-ray energies and producing high-contrast images of large and complex specimens. One entire breast of an 80-year-old woman with invasive ductal cancer was imaged using ABI-CT with monochromatic 70 keV x-rays and an area detector of 92×92 µm2 pixel size. Sagittal slices were reconstructed from the acquired data, and compared to corresponding histological sections. Comparison with conventional absorption-based CT was also performed. Five blinded radiologists quantitatively evaluated the visual aspects of the ABI-CT images with respect to sharpness, soft tissue contrast, tissue boundaries and the discrimination of different structures/tissues. ABI-CT excellently depicted the entire 3D architecture of the breast volume by providing high-resolution and high-contrast images of the normal and cancerous breast tissues. These results are an important step in the evolution of PCI-CT towards its clinical implementation.
NASA Astrophysics Data System (ADS)
Barufaldi, Bruno; Borges, Lucas R.; Bakic, Predrag R.; Vieira, Marcelo A. C.; Schiabel, Homero; Maidment, Andrew D. A.
2017-03-01
Automatic exposure control (AEC) is used in mammography to obtain acceptable radiation dose and adequate image quality regardless of breast thickness and composition. Although there are physics methods for assessing the AEC, it is not clear whether mammography systems operate with optimal dose and image quality in clinical practice. In this work, we propose the use of a normalized anisotropic quality index (NAQI), validated in previous studies, to evaluate the quality of mammograms acquired using AEC. The authors used a clinical dataset that consists of 561 patients and 1,046 mammograms (craniocaudal breast views). The results show that image quality is often maintained, even at various radiation levels (mean NAQI = 0.14 +/- 0.02). However, a more careful analysis of NAQI reveals that the average image quality decreases as breast thickness increases. The NAQI is reduced by 32% on average, when the breast thickness increases from 31 to 71 mm. NAQI also decreases with lower breast density. The variation in breast parenchyma alone cannot fully account for the decrease of NAQI with thickness. Examination of images shows that images of large, fatty breasts are often inadequately processed. This work shows that NAQI can be applied in clinical mammograms to assess mammographic image quality, and highlights the limitations of the automatic exposure control for some images.
NASA Astrophysics Data System (ADS)
Heijblom, M.; Piras, D.; Brinkhuis, M.; van Hespen, J. C. G.; van den Engh, F. M.; van der Schaaf, M.; Klaase, J. M.; van Leeuwen, T. G.; Steenbergen, W.; Manohar, S.
2015-07-01
Photoacoustic (optoacoustic) imaging can visualize vasculature deep in tissue using the high contrast of hemoglobin to light, with the high-resolution possible with ultrasound detection. Since angiogenesis, one of the hallmarks of cancer, leads to increased vascularity, photoacoustics holds promise in imaging breast cancer as shown in proof-of-principle studies. Here for the first time, we investigate if there are specific photoacoustic appearances of breast malignancies which can be related to the tumor vascularity, using an upgraded research imaging system, the Twente Photoacoustic Mammoscope. In addition to comparisons with x-ray and ultrasound images, in subsets of cases the photoacoustic images were compared with MR images, and with vascular staining in histopathology. We were able to identify lesions in suspect breasts at the expected locations in 28 of 29 cases. We discovered generally three types of photoacoustic appearances reminiscent of contrast enhancement types reported in MR imaging of breast malignancies, and first insights were gained into the relationship with tumor vascularity.
Cone-beam volume CT mammographic imaging: feasibility study
NASA Astrophysics Data System (ADS)
Chen, Biao; Ning, Ruola
2001-06-01
X-ray projection mammography, using a film/screen combination or digital techniques, has proven to be the most effective imaging modality for early detection of breast cancer currently available. However, the inherent superimposition of structures makes small carcinoma (a few millimeters in size) difficult to detect in the occultation case or in dense breasts, resulting in a high false positive biopsy rate. The cone-beam x-ray projection based volume imaging using flat panel detectors (FPDs) makes it possible to obtain three-dimensional breast images. This may benefit diagnosis of the structure and pattern of the lesion while eliminating hard compression of the breast. This paper presents a novel cone-beam volume CT mammographic imaging protocol based on the above techniques. Through computer simulation, the key issues of the system and imaging techniques, including the x-ray imaging geometry and corresponding reconstruction algorithms, x-ray characteristics of breast tissues, x-ray setting techniques, the absorbed dose estimation and the quantitative effect of x-ray scattering on image quality, are addressed. The preliminary simulation results support the proposed cone-beam volume CT mammographic imaging modality in respect to feasibility and practicability for mammography. The absorbed dose level is comparable to that of current two-view mammography and would not be a prominent problem for this imaging protocol. Compared to traditional mammography, the proposed imaging protocol with isotropic spatial resolution will potentially provide significantly better low contrast detectability of breast tumors and more accurate location of breast lesions.
Ding, Jie; Stopeck, Alison T; Gao, Yi; Marron, Marilyn T; Wertheim, Betsy C; Altbach, Maria I; Galons, Jean-Philippe; Roe, Denise J; Wang, Fang; Maskarinec, Gertraud; Thomson, Cynthia A; Thompson, Patricia A; Huang, Chuan
2018-04-06
Increased breast density is a significant independent risk factor for breast cancer, and recent studies show that this risk is modifiable. Hence, breast density measures sensitive to small changes are desired. Utilizing fat-water decomposition MRI, we propose an automated, reproducible breast density measurement, which is nonionizing and directly comparable to mammographic density (MD). Retrospective study. The study included two sample sets of breast cancer patients enrolled in a clinical trial, for concordance analysis with MD (40 patients) and reproducibility analysis (10 patients). The majority of MRI scans (59 scans) were performed with a 1.5T GE Signa scanner using radial IDEAL-GRASE sequence, while the remaining (seven scans) were performed with a 3T Siemens Skyra using 3D Cartesian 6-echo GRE sequence with a similar fat-water separation technique. After automated breast segmentation, breast density was calculated using FraGW, a new measure developed to reliably reflect the amount of fibroglandular tissue and total water content in the entire breast. Based on its concordance with MD, FraGW was calibrated to MR-based breast density (MRD) to be comparable to MD. A previous breast density measurement, Fra80-the ratio of breast voxels with <80% fat fraction-was also calculated for comparison with FraGW. Pearson correlation was performed between MD (reference standard) and FraGW (and Fra80). Test-retest reproducibility of MRD was evaluated using the difference between test-retest measures (Δ 1-2 ) and intraclass correlation coefficient (ICC). Both FraGW and Fra80 were strongly correlated with MD (Pearson ρ: 0.96 vs. 0.90, both P < 0.0001). MRD converted from FraGW showed higher test-retest reproducibility (Δ 1-2 variation: 1.1% ± 1.2%; ICC: 0.99) compared to MD itself (literature intrareader ICC ≤0.96) and Fra80. The proposed MRD is directly comparable with MD and highly reproducible, which enables the early detection of small breast density changes and treatment response. 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2018. © 2018 International Society for Magnetic Resonance in Medicine.
Harnessing the Power of Light to See and Treat Breast Cancer
2014-10-01
effect of novel therapeutic agents in vivo. 15. SUBJECT TERMS optical spectroscopy, imaging , fiber-optic, molecular, screening, breast cancer 16...therapeutic agents in vivo. a. Original Statement of Work for 5 Years Aim 1: Optical imaging of margin morphology on breast lumpectomy specimens: To...evaluate the role of wide-field imaging (coverage) and high-resolution interrogation (localization) of breast margin morphology to guide surgical
Opto-acoustic image fusion technology for diagnostic breast imaging in a feasibility study
NASA Astrophysics Data System (ADS)
Zalev, Jason; Clingman, Bryan; Herzog, Don; Miller, Tom; Ulissey, Michael; Stavros, A. T.; Oraevsky, Alexander; Lavin, Philip; Kist, Kenneth; Dornbluth, N. C.; Otto, Pamela
2015-03-01
Functional opto-acoustic (OA) imaging was fused with gray-scale ultrasound acquired using a specialized duplex handheld probe. Feasibility Study findings indicated the potential to more accurately characterize breast masses for cancer than conventional diagnostic ultrasound (CDU). The Feasibility Study included OA imagery of 74 breast masses that were collected using the investigational Imagio® breast imaging system. Superior specificity and equal sensitivity to CDU was demonstrated, suggesting that OA fusion imaging may potentially obviate the need for negative biopsies without missing cancers in a certain percentage of breast masses. Preliminary results from a 100 subject Pilot Study are also discussed. A larger Pivotal Study (n=2,097 subjects) is underway to confirm the Feasibility Study and Pilot Study findings.
Breast Imaging in the Era of Big Data: Structured Reporting and Data Mining.
Margolies, Laurie R; Pandey, Gaurav; Horowitz, Eliot R; Mendelson, David S
2016-02-01
The purpose of this article is to describe structured reporting and the development of large databases for use in data mining in breast imaging. The results of millions of breast imaging examinations are reported with structured tools based on the BI-RADS lexicon. Much of these data are stored in accessible media. Robust computing power creates great opportunity for data scientists and breast imagers to collaborate to improve breast cancer detection and optimize screening algorithms. Data mining can create knowledge, but the questions asked and their complexity require extremely powerful and agile databases. New data technologies can facilitate outcomes research and precision medicine.
Pertuz, Said; McDonald, Elizabeth S; Weinstein, Susan P; Conant, Emily F; Kontos, Despina
2016-04-01
To assess a fully automated method for volumetric breast density (VBD) estimation in digital breast tomosynthesis (DBT) and to compare the findings with those of full-field digital mammography (FFDM) and magnetic resonance (MR) imaging. Bilateral DBT images, FFDM images, and sagittal breast MR images were retrospectively collected from 68 women who underwent breast cancer screening from October 2011 to September 2012 with institutional review board-approved, HIPAA-compliant protocols. A fully automated computer algorithm was developed for quantitative estimation of VBD from DBT images. FFDM images were processed with U.S. Food and Drug Administration-cleared software, and the MR images were processed with a previously validated automated algorithm to obtain corresponding VBD estimates. Pearson correlation and analysis of variance with Tukey-Kramer post hoc correction were used to compare the multimodality VBD estimates. Estimates of VBD from DBT were significantly correlated with FFDM-based and MR imaging-based estimates with r = 0.83 (95% confidence interval [CI]: 0.74, 0.90) and r = 0.88 (95% CI: 0.82, 0.93), respectively (P < .001). The corresponding correlation between FFDM and MR imaging was r = 0.84 (95% CI: 0.76, 0.90). However, statistically significant differences after post hoc correction (α = 0.05) were found among VBD estimates from FFDM (mean ± standard deviation, 11.1% ± 7.0) relative to MR imaging (16.6% ± 11.2) and DBT (19.8% ± 16.2). Differences between VDB estimates from DBT and MR imaging were not significant (P = .26). Fully automated VBD estimates from DBT, FFDM, and MR imaging are strongly correlated but show statistically significant differences. Therefore, absolute differences in VBD between FFDM, DBT, and MR imaging should be considered in breast cancer risk assessment.
Zhou, Lian; Li, Xu; Zhu, Shanan; He, Bin
2011-01-01
Magnetoacoustic tomography with magnetic induction (MAT-MI) was recently introduced as a noninvasive electrical conductivity imaging approach with high spatial resolution close to ultrasound imaging. In the present study, we test the feasibility of the MAT-MI method for breast tumor imaging using numerical modeling and computer simulation. Using the finite element method, we have built three dimensional numerical breast models with varieties of embedded tumors for this simulation study. In order to obtain an accurate and stable forward solution that does not have numerical errors caused by singular MAT-MI acoustic sources at conductivity boundaries, we first derive an integral forward method for calculating MAT-MI acoustic sources over the entire imaging volume. An inverse algorithm for reconstructing the MAT-MI acoustic source is also derived with spherical measurement aperture, which simulates a practical setup for breast imaging. With the numerical breast models, we have conducted computer simulations under different imaging parameter setups and all the results suggest that breast tumors that have large conductivity contrast to its surrounding tissues as reported in literature may be readily detected in the reconstructed MAT-MI images. In addition, our simulations also suggest that the sensitivity of imaging breast tumors using the presented MAT-MI setup depends more on the tumor location and the conductivity contrast between the tumor and its surrounding tissues than on the tumor size. PMID:21364262
Evaluation of Social Support, Quality of Life, and Body Image in Women with Breast Cancer.
Spatuzzi, Roberta; Vespa, Anna; Lorenzi, Primo; Miccinesi, Guido; Ricciuti, Marcello; Cifarelli, Wanda; Susi, Marina; Fabrizio, Tommaso; Ferrari, Maria G; Ottaviani, Marica; Giulietti, Maria V; Merico, Fabiana; Aieta, Michele
2016-02-01
This study was aimed at comparing the quality of life, body image, and perceived social support in women with breast cancer surgery. Patients receiving breast-conserving surgery (BCS) (n = 72), mastectomy alone (n = 44), and mastectomy with breast reconstruction (n = 41) were evaluated using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ-C30), the EORTC Breast Cancer Module (QLQ-BR23), the Body Image Scale (BIS) and the Multidimensional Scale of Perceived Social Support (MSPSS). The results indicated that the BCS group had a better body image compared with the other 2 groups and better role functioning compared with the mastectomy-alone group. In the reconstruction group, body image correlated with perceived social support, especially from family and significant others. These results suggest that a positive perception of a supportive social network can help women with breast reconstruction to better cope with the psychological effects of surgery on their body image.
Optical Imaging in Breast Cancer Diagnosis: The Next Evolution
Ruibal, Alvaro
2012-01-01
Breast cancer is one of the most common cancers among the population of the Western world. Diagnostic methods include mammography, ultrasound, and magnetic resonance; meanwhile, nuclear medicine techniques have a secondary role, being useful in regional assessment and therapy followup. Optical imaging is a very promising imaging technique that uses near-infrared light to assess optical properties of tissues and is expected to play an important role in breast cancer detection. Optical breast imaging can be performed by intrinsic breast tissue contrast alone (hemoglobin, water, and lipid content) or with the use of exogenous fluorescent probes that target specific molecules for breast cancer. Major advantages of optical imaging are that it does not use any radioactive components, very high sensitivity, relatively inexpensive, easily accessible, and the potential to be combined in a multimodal approach with other technologies such as mammography, ultrasound, MRI, and positron emission tomography. Moreover, optical imaging agents could, potentially, be used as “theranostics,” combining the process of diagnosis and therapy. PMID:23304141
Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound
NASA Astrophysics Data System (ADS)
Cucciati, G.; Auffray, E.; Bugalho, R.; Cao, L.; Di Vara, N.; Farina, F.; Felix, N.; Frisch, B.; Ghezzi, A.; Juhan, V.; Jun, D.; Lasaygues, P.; Lecoq, P.; Mensah, S.; Mundler, O.; Neves, J.; Paganoni, M.; Peter, J.; Pizzichemi, M.; Siles, P.; Silva, J. C.; Silva, R.; Tavernier, S.; Tessonnier, L.; Varela, J.
2014-03-01
ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information.
Full-view 3D imaging system for functional and anatomical screening of the breast
NASA Astrophysics Data System (ADS)
Oraevsky, Alexander; Su, Richard; Nguyen, Ha; Moore, James; Lou, Yang; Bhadra, Sayantan; Forte, Luca; Anastasio, Mark; Yang, Wei
2018-04-01
Laser Optoacoustic Ultrasonic Imaging System Assembly (LOUISA-3D) was developed in response to demand of diagnostic radiologists for an advanced screening system for the breast to improve on low sensitivity of x-ray based modalities of mammography and tomosynthesis in the dense and heterogeneous breast and low specificity magnetic resonance imaging. It is our working hypothesis that co-registration of quantitatively accurate functional images of the breast vasculature and microvasculature, and anatomical images of breast morphological structures will provide a clinically viable solution for the breast cancer care. Functional imaging is LOUISA-3D is enabled by the full view 3D optoacoustic images acquired at two rapidly toggling laser wavelengths in the near-infrared spectral range. 3D images of the breast anatomical background is enabled in LOUISA-3D by a sequence of B-mode ultrasound slices acquired with a transducer array rotating around the breast. This creates the possibility to visualize distributions of the total hemoglobin and blood oxygen saturation within specific morphological structures such as tumor angiogenesis microvasculature and larger vasculature in proximity of the tumor. The system has four major components: (i) a pulsed dual wavelength laser with fiberoptic light delivery system, (ii) an imaging module with two arc shaped probes (optoacoustic and ultrasonic) placed in a transparent bowl that rotates around the breast, (iii) a multichannel electronic system with analog preamplifiers and digital data acquisition boards, and (iv) computer for the system control, data processing and image reconstruction. The most important advancement of this latest system design compared with previously reported systems is the full breast illumination accomplished for each rotational step of the optoacoustic transducer array using fiberoptic illuminator rotating around the breast independently from rotation of the detector probe. We report here a pilot case studies on one healthy volunteer and on patient with a suspicious small lesion in the breast. LOUISA3D visualized deoxygenated veins and oxygenated arteries of a healthy volunteer, indicative of its capability to visualize hypoxic microvasculature in cancerous tumors. A small lesion detected on optoacoustic image of a patient was not visible on ultrasound, potentially indicating high system sensitivity of the optoacoustic subsystem to small but aggressively growing cancerous lesions with high density angiogenesis microvasculature. The main breast vasculature (0.5-1 mm) was visible at depth of up to 40-mm with 0.3-mm resolution. The results of LOUISA-3D pilot clinical validation demonstrated the system readiness for statistically significant clinical feasibility study.
Swerts, Marlies; Westhof, Ellen; Bogaerts, Annick; Lemiengre, Joke
2016-06-01
In 2003 the World Health Organization (WHO) recommended that infants should be fed exclusively with breast milk until the age of six months. However, breast feeding rates remain lower than recommended. The crucial period for breast feeding support is the first two weeks after birth. During this period breast feeding support from the midwife is needed. The aim of this paper is to gain an in-depth understanding of the role of midwives in their support of breast-feeding women, from their own perspective. Two researchers independently conducted a systematic and comprehensive literature search. Studies needed an empirical qualitative research design (1), had to focus on the role of the midwife in the support of the breast-feeding woman from the midwife's perspective (2), and had to be published between January 2005 and December 2014 (3) in order to be included. Language restrictions were English, Dutch, German and French. Eight qualitative research studies were included, using mainly focus group and in-depth interview studies, which were reported in 11 papers representing 231 midwives and 24 maternity nurses. All but one study concerned midwives working in hospital settings. A critical appraisal was performed of each study. Midwives value breast feeding education and breast feeding support as a significant part of their role as a postnatal midwife. However, the ways in which a midwife approaches and supports the breast-feeding woman vary. We distinguished two perspectives: 'the midwife as technical expert' and 'the midwife as a skilled companion'. The 'technical expert' midwife is mainly breast centred, focuses on techniques, uses the hands on approach and sees a woman as a novice. The 'skilled companion' midwife is woman centred, focuses on the mother - infant relationship and uses a hands off approach during the breast feeding support. The midwives working in a hospital setting face many barriers when performing breast feeding support, such as time restraints, which makes it difficult for them to carry out their preferred role as a 'skilled companion'. These barriers can influence the breast feeding support negatively. Supporting factors, such as evidence based breast feeding guidelines, have a positive influence on the breast feeding support. On the basis of findings of a synthesis of qualitative research studies, we conclude that the majority of the midwives provide breast feeding support as a technical expert and a minority as a skilled companion. Midwives prefer to be a skilled companion but face many barriers in their working contexts. Copyright © 2016. Published by Elsevier Ltd.
Understanding Clinical Mammographic Breast Density Assessment: a Deep Learning Perspective.
Mohamed, Aly A; Luo, Yahong; Peng, Hong; Jankowitz, Rachel C; Wu, Shandong
2017-09-20
Mammographic breast density has been established as an independent risk marker for developing breast cancer. Breast density assessment is a routine clinical need in breast cancer screening and current standard is using the Breast Imaging and Reporting Data System (BI-RADS) criteria including four qualitative categories (i.e., fatty, scattered density, heterogeneously dense, or extremely dense). In each mammogram examination, a breast is typically imaged with two different views, i.e., the mediolateral oblique (MLO) view and cranial caudal (CC) view. The BI-RADS-based breast density assessment is a qualitative process made by visual observation of both the MLO and CC views by radiologists, where there is a notable inter- and intra-reader variability. In order to maintain consistency and accuracy in BI-RADS-based breast density assessment, gaining understanding on radiologists' reading behaviors will be educational. In this study, we proposed to leverage the newly emerged deep learning approach to investigate how the MLO and CC view images of a mammogram examination may have been clinically used by radiologists in coming up with a BI-RADS density category. We implemented a convolutional neural network (CNN)-based deep learning model, aimed at distinguishing the breast density categories using a large (15,415 images) set of real-world clinical mammogram images. Our results showed that the classification of density categories (in terms of area under the receiver operating characteristic curve) using MLO view images is significantly higher than that using the CC view. This indicates that most likely it is the MLO view that the radiologists have predominately used to determine the breast density BI-RADS categories. Our study holds a potential to further interpret radiologists' reading characteristics, enhance personalized clinical training to radiologists, and ultimately reduce reader variations in breast density assessment.
Differentiation of benign and malignant breast lesions by mechanical imaging
Kearney, Thomas; Pollak, Stanley B.; Rohatgi, Chand; Sarvazyan, Noune; Airapetian, Suren; Browning, Stephanie; Sarvazyan, Armen
2009-01-01
Mechanical imaging yields tissue elasticity map and provides quantitative characterization of a detected pathology. The changes in the surface stress patterns as a function of applied load provide information about the elastic composition and geometry of the underlying tissue structures. The objective of this study is the clinical evaluation of breast mechanical imager for breast lesion characterization and differentiation between benign and malignant lesions. The breast mechanical imager includes a probe with pressure sensor array, an electronic unit providing data acquisition from the pressure sensors and communication with a touch-screen laptop computer. We have developed an examination procedure and algorithms to provide assessment of breast lesion features such as hardness related parameters, mobility, and shape. A statistical Bayesian classifier was constructed to distinguish between benign and malignant lesions by utilizing all the listed features as the input. Clinical results for 179 cases, collected at four different clinical sites, have demonstrated that the breast mechanical imager provides a reliable image formation of breast tissue abnormalities and calculation of lesion features. Malignant breast lesions (histologically confirmed) demonstrated increased hardness and strain hardening as well as decreased mobility and longer boundary length in comparison with benign lesions. Statistical analysis of differentiation capability for 147 benign and 32 malignant lesions revealed an average sensitivity of 91.4% and specificity of 86.8% with a standard deviation of ±6.1%. The area under the receiver operating characteristic curve characterizing benign and malignant lesion discrimination is 86.1% with the confidence interval ranging from 80.3 to 90.9%, with a significance level of P = 0.0001 (area = 50%). The multisite clinical study demonstrated the capability of mechanical imaging for characterization and differentiation of benign and malignant breast lesions. We hypothesize that the breast mechanical imager has the potential to be used as a cost effective device for cancer diagnostics that could reduce the benign biopsy rate, serve as an adjunct to mammography and to be utilized as a screening device for breast cancer detection. PMID:19306059
Crotty, Dominic J; Brady, Samuel L; Jackson, D'Vone C; Toncheva, Greta I; Anderson, Colin E; Yoshizumi, Terry T; Tornai, Martin P
2011-06-01
A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging.
Crotty, Dominic J.; Brady, Samuel L.; Jackson, D’Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.
2011-01-01
Purpose: A dual modality SPECT-CT prototype system dedicated to uncompressed breast imaging (mammotomography) has been developed. The computed tomography subsystem incorporates an ultrathick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam that optimizes the dose efficiency of the system for lesion imaging in an uncompressed breast. Here, the absorbed dose in various geometric phantoms and in an uncompressed and pendant cadaveric breast using a normal tomographic cone beam imaging protocol is characterized using both thermoluminescent dosimeter (TLD) measurements and ionization chamber-calibrated radiochromic film. Methods: Initially, two geometric phantoms and an anthropomorphic breast phantom are filled in turn with oil and water to simulate the dose to objects that mimic various breast shapes having effective density bounds of 100% fatty and glandular breast compositions, respectively. Ultimately, an excised human cadaver breast is tomographically scanned using the normal tomographic imaging protocol, and the dose to the breast tissue is evaluated and compared to the earlier phantom-based measurements. Results: Measured trends in dose distribution across all breast geometric and anthropomorphic phantom volumes indicate lower doses in the medial breast and more proximal to the chest wall, with consequently higher doses near the lateral peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes due to the reduced mass energy-absorption coefficient of oil relative to water. The mean measured dose to the breast cadaver, composed of adipose and glandular tissues, was measured to be 4.2 mGy compared to a mean whole-breast dose of 3.8 and 4.5 mGy for the oil- and water-filled anthropomorphic breast phantoms, respectively. Conclusions: Assuming rotational symmetry due to the tomographic acquisition exposures, these results characterize the 3D dose distributions in an uncompressed human breast tissue volume for this dedicated breast imaging device and illustrate advantages of using the novel ultrathick K-edge filtered beam to minimize the dose to the breast during fully-3D imaging. PMID:21815398
Gan, Qi; Wang, Dong; Ye, Jian; Zhang, Zeshu; Wang, Xinrui; Hu, Chuanzhen; Shao, Pengfei; Xu, Ronald X.
2016-01-01
We propose a projective navigation system for fluorescence imaging and image display in a natural mode of visual perception. The system consists of an excitation light source, a monochromatic charge coupled device (CCD) camera, a host computer, a projector, a proximity sensor and a Complementary metal–oxide–semiconductor (CMOS) camera. With perspective transformation and calibration, our surgical navigation system is able to achieve an overall imaging speed higher than 60 frames per second, with a latency of 330 ms, a spatial sensitivity better than 0.5 mm in both vertical and horizontal directions, and a projection bias less than 1 mm. The technical feasibility of image-guided surgery is demonstrated in both agar-agar gel phantoms and an ex vivo chicken breast model embedding Indocyanine Green (ICG). The biological utility of the system is demonstrated in vivo in a classic model of ICG hepatic metabolism. Our benchtop, ex vivo and in vivo experiments demonstrate the clinical potential for intraoperative delineation of disease margin and image-guided resection surgery. PMID:27391764
2014-09-01
to develop an optimized system design and associated image reconstruction algorithms for a hybrid three-dimensional (3D) breast imaging system that...research is to develop an optimized system design and associated image reconstruction algorithms for a hybrid three-dimensional (3D) breast imaging ...i) developed time-of- flight extraction algorithms to perform USCT, (ii) developing image reconstruction algorithms for USCT, (iii) developed
Hari, Smriti; Kumari, Swati; Srivastava, Anurag; Thulkar, Sanjay; Mathur, Sandeep; Veedu, Prasad Thotton
2016-01-01
Background & objectives: Biopsy of palpable breast masses can be performed manually by palpation guidance or under imaging guidance. Based on retrospective studies, image guided biopsy is considered more accurate than palpation guided breast biopsy; however, these techniques have not been compared prospectively. We conducted this prospective study to verify the superiority and determine the size of beneficial effect of image guided biopsy over palpation guided biopsy. Methods: Over a period of 18 months, 36 patients each with palpable breast masses were randomized into palpation guided and image guided breast biopsy arms. Ultrasound was used for image guidance in 33 patients and mammographic (stereotactic) guidance in three patients. All biopsies were performed using 14 gauge automated core biopsy needles. Inconclusive, suspicious or imaging-histologic discordant biopsies were repeated. Results: Malignancy was found in 30 of 36 women in palpation guided biopsy arm and 27 of 36 women in image guided biopsy arm. Palpation guided biopsy had sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 46.7, 100, 100, 27.3 per cent, respectively, for diagnosing breast cancer. Nineteen of 36 women (52.8%) required repeat biopsy because of inadequate samples (7 of 19), suspicious findings (2 of 19) or imaging-histologic discordance (10 of 19). On repeat biopsy, malignancy was found in all cases of imaging-histologic discordance. Image guided biopsy had 96.3 per cent sensitivity and 100 per cent specificity. There was no case of inadequate sample or imaging-histologic discordance with image guided biopsy. Interpretation & conclusions: Our results showed that in palpable breast masses, image guided biopsy was superior to palpation guided biopsy in terms of sensitivity, false negative rate and repeat biopsy rates. PMID:27488003
NASA Astrophysics Data System (ADS)
Hebden, Jeremy C.; Rinneberg, Herbert
2005-06-01
The Commission of the European Union (EU) conceived its Fifth Framework Programme (FP5) to identify the priorities for the European Union's research, technological development and demonstration activities for the period 1998-2002. By encouraging collaborative research between groups in different member countries, FP5 was intended to help solve problems the EU is facing and respond to major socio-economic challenges. The programme focused on a number of objectives and areas combining technological, industrial, economic, social and cultural aspects. A specific call was made, under its `Quality of Life and Management of Living Resources' section, for proposals which aim to explore improvements in non-invasive methods of imaging for early diagnosis and clinical evaluation of disease. Among the projects successfully funded under the FP5 programme was one entitled `Optical mammography: Imaging and characterization of breast lesions by pulsed near-infrared laser light', known by its acronym OPTIMAMM. The project involved a consortium of nine partners, comprising ten applied science and clinical research groups based in six EU countries, with overall administration and management provided by the Physikalisch-Technische Bundesanstalt, Berlin, Germany. The broad aim of the OPTIMAMM project was to combine multi-disciplinary basic (physics, engineering, mathematics, computer science) and clinical (oncology, histology) research to assess the diagnostic potential of time-domain optical and photoacoustic mammography as novel, non-invasive imaging modalities for the detection and clinical evaluation of breast lesions. Funding for the project, at a total cost of about 1.67 MEuro, began in December 2000 for a period of three years, although a zero-cost extension was granted to enable the ongoing project activities to continue until the end of May 2004. The importance of developing new tools for the detection and diagnosis of breast disease is evident from the very high incidence and mortality associated with it, within the EU and throughout the world. Although x-ray mammography is recognized as an effective tool for cancer screening in women over 35-40 years of age, it suffers from a significant number of false positives which often lead to unnecessary biopsy. X-ray mammography is also less effective for younger women with denser breasts, and involves the use of potentially harmful ionizing radiation. While other conventional diagnostic techniques such as ultrasound and magnetic resonance imaging (MRI) are also widely used in the diagnosis and characterization of breast disease, their roles in the detection and staging of breast tumours have so far been limited. The development of optical methods of imaging the breast is attractive partly because they are safe, but chiefly because they can reveal contrast between normal and diseased tissues which are not evident using conventional methods. The principal mechanism for contrast at near-infrared wavelengths is the characteristic absorption by haemoglobin and other dominant tissue chromophores, such as fat and water. Furthermore, the differences between the absorption of oxy-haemoglobin and deoxy-hemoglobin provide a means of determining oxygenation, and therefore of studying tissue function. The OPTIMAMM project focused specifically on the diagnostic potential of time-resolved methods. Systems which measure the flight-times of photons transmitted across highly scattering breast tissue offer the potential to provide greater spatial resolution and contrast than systems based on intensity measurements alone, and facilitate better separation between the effects of scatter and those of absorption. A major component of the project was a series of clinical trials performed at four European sites, in particular in Berlin (Germany) and Milan (Italy) using similar scanning instrumentation, carried out under a harmonized clinical protocol where appropriate. The clinical trials were augmented by efforts to refine semi-empirical and rigorous mathematical methods for data analysis and image reconstruction, and by technical improvements to instrumentation. Throughout the project, developments in technology and methodology were assessed through appropriate evaluation on human subjects. The nine project partners also applied different measurement techniques to a concerted effort to reliably measure the scattering and absorption properties of normal breast tissue, benign lesions and tumours at various near-infrared wavelengths in vivo non-invasively, during breast surgery, and ex vivo on tissue specimens and biopsy samples. In May 2004, on the successful completion of the OPTIMAMM project, a European workshop entitled `Applied Medical Photonics: from Tissue Characterization to Optical Mammography' was held in Berlin, jointly organized by the OPTIMAMM consortium and by another consortium representing the European network on `Medical Photonics'. At this meeting, all the the OPTIMAMM partners presented summaries of their results obtained during the lifetime of the project. Subsequently, the ten collaborating research groups have prepared a series of papers which focus on the specific results of the consortia and review its overall achievements. This special issue of Physics in Medicine and Biology presents these ten papers (pages 2429-2596), which have been accepted for publication following the usual thorough peer-review process for this journal. The first four papers describe the results of the two parallel clinical assessments of scanning time-domain optical mammography, involving a combined total of about 350 patients. These include descriptions of technical developments and the results of efforts to determine the optical properties of benign lesions and carcinomas. The first two contributions summarize the work performed by collaborating groups based in Berlin. A scanning laser pulse optical mammograph, which records craniocaudal and mediolateral projection images of the compressed breast at three near-infrared wavelengths, was used in a clinical trial on 154 patients, all undergoing subsequent histological assessment of at least one breast lesion. Part I describes an analysis of optical images by comparing them with x-ray and MRI mammograms and with results of histopathology. Part II reports on the derived optical properties of a subset of 87 carcinomas. Haemoglobin concentration was found to be systematically higher in tumours than in normal tissue, while no statistical difference was observed for blood oxygenation. A similar breast imaging system is the focus of the next two papers, presented by partners based in Milan. A clinical study involving a total of 194 patients was performed over the lifetime of the project, during which the number of discrete wavelengths employed increased from four to seven, and the spectral range was expanded to accommodate wavelengths above 900 nm. The first of this pair of papers describes the effectiveness of the system for detecting breast lesions, while the second presents an attempt to characterize the optical properties of malignant and benign lesions. Again, cancers were found to associate with a blood content that is higher than in surrounding tissues. The fifth paper in this special issue, authored by consortium partners in London (UK), reports clinical results achieved using a 32-channel time-resolved optical tomography system. Cross-sectional images of the uncompressed human breast are generated from photon flight-time measurements using an iterative, non-linear algorithm. Studies involving patients with a variety of breast conditions detected 17 out of 19 lesions, and results on healthy volunteers displayed heterogeneity which was repeatable over a period of months. The next paper represents a collaboration between the London researchers working on image reconstruction algorithm development, and partners based in Berlin. A paraxial scanning mechanism developed for the Berlin breast imaging system was used to acquire measurements which enable three-dimensional (3D) in vivo images to be generated. A fast reconstruction method, based on the Rytov approximation, uses data which is Fourier transformed with respect to both time and space. The seventh paper, contributed by partners based in Enschede (The Netherlands), provides an overview of their breast imaging system which measures photoacoustic signals occurring within tissue in response to illumination by short pulses of light. The overall performance of the system is discussed, and an algorithm is presented which is designed to utilize these measurements to generate 3D images of the compressed breast. The remaining three papers focus on the measurement of the optical properties of breast tissue. The first of these presents the results of an investigation of the intra- and inter-subject variability of optical properties, and of the relative concentrations of principle chromophores: water, lipid, and haemoglobin. This collaborative study, involving partners based in Lund (Sweden) and Milan, utilized in vivo time-resolved spectroscopy measurements at four near-infrared wavelengths. Differences between pre- and post-menopausal breast tissues were confirmed, and no systematic differences between contralateral breast were evident. The next paper, authored by researchers in Rotterdam (The Netherlands), describes the use of a fibre-optic needle probe and a technique known as differential pathlength spectroscopy to derive highly localized optical properties of the breast in vivo. Results, correlated with histological outcome, reveal that malignant tissue is characterized by a significant decrease in tissue oxygenation and a higher blood content compared with normal breast tissue. The last paper in this special issue describes a theoretical development which enables a more accurate determination of scattering properties from small biopsy samples. The theory was applied by the authors based in Heraklion (Greece) to time-resolved transmittance measurements in order to characterize the scattering of 59 samples of breast tissue. We are grateful to all the authors for their valuable contributions and their prompt responses to reviewers' comments, and we thank all the reviewers for their useful suggestions to improve the quality of the papers and their considerable efforts to meet tight deadlines. And last but not least we would like to thank the European Commission for its generous financial support.
Radionuclide Methods and Instrumentation for Breast Cancer Detection and Diagnosis
Surti, Suleman
2013-01-01
Breast cancer mammography is a well-acknowledged technique for patient screening due to its high sensitivity. However, in addition to its low specificity the sensitivity of mammography is limited when imaging patients with dense breasts. Radionuclide imaging techniques, such as coincidence photon-based positron emission tomography and single photon emission computed tomography or scintimammography, can play a role in assisting screening of such patients. Radionuclide techniques can also be useful in assessing treatment response of patients with breast cancer to therapy, and staging of patients to diagnose the disease extent. However, the performance of these imaging modalities is generally limited because of the poor spatial resolution and sensitivity of the commercially available multipurpose imaging systems. Here, we describe some of the dedicated imaging systems (positron emission mammography [PEM] and breast-specific gamma imaging [BSGI]) that have been developed both commercially and in research laboratories for radionuclide imaging of breast cancer. Clinical studies with dedicated PEM scanners show improved sensitivity to detecting cancer in patients when using PEM in conjunction with additional imaging modalities, such as magnetic resonance imaging or mammography or both, as well as improved disease staging that can have an effect on surgical planning. High-resolution BSGI systems are more widely available commercially and several clinical studies have shown very high sensitivity and specificity in detecting cancer in high-risk patients. Further development of dedicated PEM and BSGI systems is ongoing, promising further expansion of radionuclide imaging techniques in the realm of breast cancer detection and treatment. PMID:23725989
Yano, Kenji; Taminato, Mifue; Nomori, Michiko; Hosokawa, Ko
2017-01-01
Background: Autologous breast reconstruction can be performed for breasts with ptosis to a certain extent, but if patients desire to correct ptosis, mastopexy of the contralateral breast is indicated. However, accurate prediction of post-mastopexy breast shape is difficult to make, and symmetrical breast reconstruction requires certain experience. We have previously reported the use of three-dimensional (3D) imaging and printing technologies in deep inferior epigastric artery perforator (DIEP) flap breast reconstruction. In the present study, these technologies were applied to the reconstruction of breasts with ptosis. Methods: Eight breast cancer patients with ptotic breasts underwent two-stage unilateral DIEP flap breast reconstruction. In the initial surgery, tissue expander (TE) placement and contralateral mastopexy are performed simultaneously. Four to six months later, 3D bilateral breast imaging is performed after confirming that the shape of the contralateral breast (post-mastopexy) is somewhat stabilized, and a 3D-printed breast mold is created based on the mirror image of the shape of the contralateral breast acquired using analytical software. Then, DIEP flap surgery is performed, where the breast mold is used to determine the required flap volume and to shape the breast mound. Results: All flaps were engrafted without any major perioperative complications during both the initial and DIEP flap surgeries. Objective assessment of cosmetic outcome revealed that good breast symmetry was achieved in all cases. Conclusions: The method described here may allow even inexperienced surgeons to achieve reconstruction of symmetrical, non-ptotic breasts with ease and in a short time. While the requirement of two surgeries is a potential disadvantage, our method will be particularly useful in cases involving TEs, i.e., delayed reconstruction or immediate reconstruction involving significant skin resection. PMID:29184728
DOE Office of Scientific and Technical Information (OSTI.GOV)
Albanese, K; Morris, R; Spencer, J
Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (asmore » a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs (e.g., lung).« less
Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q.; Ducote, Justin L.; Su, Min-Ying; Molloi, Sabee
2013-01-01
Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson's r, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson's r increased from 0.86 to 0.92 with the bias field correction. Conclusions: The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications. PMID:24320536
Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q; Ducote, Justin L; Su, Min-Ying; Molloi, Sabee
2013-12-01
Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left-right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson's r, was used to evaluate the two image segmentation algorithms and the effect of bias field. The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left-right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left-right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson's r increased from 0.86 to 0.92 with the bias field correction. The investigated CLIC method significantly increased the precision and accuracy of breast density quantification using breast MRI images by effectively correcting the bias field. It is expected that a fully automated computerized algorithm for breast density quantification may have great potential in clinical MRI applications.
Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters.
Sun, Wenzhao; Wang, Bin; Qiu, Bo; Liang, Jian; Xie, Weihao; Deng, Xiaowu; Qi, Zhenyu
2017-03-21
To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols and breast sizes were compared. Dose reduction was attempted by using partial arc CBCT scan with bowtie filter. The impact of this dose reduction strategy on image registration accuracy was investigated. The average breast surface doses were 20.02 mGy and 11.65 mGy for thoracic CBCT without filtration and with filtration, respectively. This indicates a dose reduction of 41.8% by use of bowtie filter. It was found 220° partial arc scanning significantly reduced the dose to contralateral breast (44.4% lower than ipsilateral breast), while the image registration accuracy was not compromised. Breast dose reduction can be achieved by using ipsilateral 220° partial arc scan with bowtie filter. This strategy also provides sufficient image quality for thorax image registration in daily patient positioning verification.
Evaluation of a breast software model for 2D and 3D X-ray imaging studies of the breast.
Baneva, Yanka; Bliznakova, Kristina; Cockmartin, Lesley; Marinov, Stoyko; Buliev, Ivan; Mettivier, Giovanni; Bosmans, Hilde; Russo, Paolo; Marshall, Nicholas; Bliznakov, Zhivko
2017-09-01
In X-ray imaging, test objects reproducing breast anatomy characteristics are realized to optimize issues such as image processing or reconstruction, lesion detection performance, image quality and radiation induced detriment. Recently, a physical phantom with a structured background has been introduced for both 2D mammography and breast tomosynthesis. A software version of this phantom and a few related versions are now available and a comparison between these 3D software phantoms and the physical phantom will be presented. The software breast phantom simulates a semi-cylindrical container filled with spherical beads of different diameters. Four computational breast phantoms were generated with a dedicated software application and for two of these, physical phantoms are also available and they are used for the side by side comparison. Planar projections in mammography and tomosynthesis were simulated under identical incident air kerma conditions. Tomosynthesis slices were reconstructed with an in-house developed reconstruction software. In addition to a visual comparison, parameters like fractal dimension, power law exponent β and second order statistics (skewness, kurtosis) of planar projections and tomosynthesis reconstructed images were compared. Visually, an excellent agreement between simulated and real planar and tomosynthesis images is observed. The comparison shows also an overall very good agreement between parameters evaluated from simulated and experimental images. The computational breast phantoms showed a close match with their physical versions. The detailed mathematical analysis of the images confirms the agreement between real and simulated 2D mammography and tomosynthesis images. The software phantom is ready for optimization purpose and extrapolation of the phantom to other breast imaging techniques. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
Sentinel lymph node biopsy under fluorescent indocyanin green guidance: Initial experience
Aydoğan, Fatih; Arıkan, Akif Enes; Aytaç, Erman; Velidedeoğlu, Mehmet; Yılmaz, Mehmet Halit; Sager, Muhammet Sait; Çelik, Varol; Uras, Cihan
2016-01-01
Objective: Sentinel lymph node biopsy can be applied by using either blue dye or radionuclide method or both in breast cancer. Fluorescent imaging with indocyanine green is a new defined method. This study evaluates the applicability of sentinel lymph node biopsy via fluorescent indocyanine green. Material and Methods: IC-VIEW (Pulsion Medical Systems AG, Munich, Germany) infrared visualization system was used for imaging. Two mL of indocyanine green was injected to visualize sentinel lymph nodes. After injection, subcutaneous lymphatics were traced and sentinel lymph nodes were found with simultaneous imaging. Sentinel lymph nodes were excised under fluorescent light guidance, and excised lymph nodes were examined histopathologically. Patients with sentinel lymph node metastases underwent axillary dissection. Results: Four patients with sentinel lymph node biopsy due to breast cancer were included in the study. Sentinel lymph nodes were visualized with indocyanine green in all patients. The median number of excised sentinel lymph node was 2 (2–3). Two patients with lymph node metastasis underwent axillary dissection. No metastasis was detected in lymph nodes other than the sentinel nodes in patients with axillary dissection. There was no complication during and after the operation related to the method. Conclusion: According to our limited experience, sentinel lymph node biopsy under fluorescent indocyanine green guidance, which has an advantage of simultaneous visualization, is technically feasible. PMID:26985159
Digital Mammography and Digital Breast Tomosynthesis.
Moseley, Tanya W
2016-06-01
Breast imaging technology has advanced significantly from the 1930s until the present. American women have a 1 in 8 chance of developing breast cancer. Mammography has been proven in multiple clinical trials to reduce breast cancer mortality. Although a mainstay of breast imaging and improved from film-screen mammography, digital mammography is not a perfect examination. Overlapping obscuring breast tissue limits mammographic interpretation. Breast digital tomosynthesis reduces and/or eliminates overlapping obscuring breast tissue. Although there are some disadvantages with digital breast tomosynthesis, this relatively lost-cost technology may be used effectively in the screening and diagnostic settings.
TU-CD-207-09: Analysis of the 3-D Shape of Patients’ Breast for Breast Imaging and Surgery Planning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agasthya, G; Sechopoulos, I
2015-06-15
Purpose: Develop a method to accurately capture the 3-D shape of patients’ external breast surface before and during breast compression for mammography/tomosynthesis. Methods: During this IRB-approved, HIPAA-compliant study, 50 women were recruited to undergo 3-D breast surface imaging during breast compression and imaging for the cranio-caudal (CC) view on a digital mammography/breast tomosynthesis system. Digital projectors and cameras mounted on tripods were used to acquire 3-D surface images of the breast, in three conditions: (a) positioned on the support paddle before compression, (b) during compression by the compression paddle and (c) the anterior-posterior view with the breast in its natural,more » unsupported position. The breast was compressed to standard full compression with the compression paddle and a tomosynthesis image was acquired simultaneously with the 3-D surface. The 3-D surface curvature and deformation with respect to the uncompressed surface was analyzed using contours. The 3-D surfaces were voxelized to capture breast shape in a format that can be manipulated for further analysis. Results: A protocol was developed to accurately capture the 3-D shape of patients’ breast before and during compression for mammography. Using a pair of 3-D scanners, the 50 patient breasts were scanned in three conditions, resulting in accurate representations of the breast surfaces. The surfaces were post processed, analyzed using contours and voxelized, with 1 mm{sup 3} voxels, converting the breast shape into a format that can be easily modified as required. Conclusion: Accurate characterization of the breast curvature and shape for the generation of 3-D models is possible. These models can be used for various applications such as improving breast dosimetry, accurate scatter estimation, conducting virtual clinical trials and validating compression algorithms. Ioannis Sechopoulos is consultant for Fuji Medical Systems USA.« less
USDA-ARS?s Scientific Manuscript database
Cooking loss (CL) is a critical quality attribute directly relating to meat juiciness. The potential of the hyperspectral imaging (HSI) technique was investigated for non-invasively classifying and visualizing the CL of fresh broiler breast meat. Hyperspectral images of total 75 fresh broiler breast...
Breast imaging using the Twente photoacoustic mammoscope (PAM): new clinical measurements
NASA Astrophysics Data System (ADS)
Heijblom, Michelle; Piras, Daniele; Ten Tije, Ellen; Xia, Wenfeng; van Hespen, Johan; Klaase, Joost; van den Engh, Frank; van Leeuwen, Ton; Steenbergen, Wiendelt; Manohar, Srirang
2011-07-01
Worldwide, yearly about 450,000 women die from the consequences of breast cancer. Current imaging modalities are not optimal in discriminating benign from malignant tissue. Visualizing the malignancy-associated increased hemoglobin concentration might significantly improve early diagnosis of breast cancer. Since photoacoustic imaging can visualize hemoglobin in tissue with optical contrast and ultrasound-like resolution, it is potentially an ideal method for early breast cancer imaging. The Twente Photoacoustic Mammoscope (PAM) has been developed specifically for breast imaging. Recently, a large clinical study has been started in the Medisch Spectrum Twente in Oldenzaal using PAM. In PAM, the breast is slightly compressed between a window for laser light illumination and a flat array ultrasound detector. The measurements are performed using a Q-switched Nd:YAG laser, pulsed at 1064 nm and a 1 MHz unfocused ultrasound detector array. Three-dimensional data are reconstructed using a delay and sum reconstruction algorithm. Those reconstructed images are compared with conventional imaging and histopathology. In the first phase of the study 12 patients with a malignant lesion and 2 patients with a benign cyst have been measured. The results are used to guide developments in photoacoustic mammography in order to pave the way towards an optimal technique for early diagnosis of breast cancer.
Kao, Tzu-Jen; Isaacson, David; Saulnier, Gary J.; Newell, Jonathan C.
2009-01-01
The conductivity and permittivity of breast tumors are known to differ significantly from those of normal breast tissues, and electrical impedance tomography (EIT) is being studied as a modality for breast cancer imaging to exploit these differences. At present, X-ray mammography is the primary standard imaging modality used for breast cancer screening in clinical practice, so it is desirable to study EIT in the geometry of mammography. This paper presents a forward model of a simplified mammography geometry and a reconstruction algorithm for breast tumor imaging using EIT techniques. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and is validated by experiment using a phantom tank. A reconstruction algorithm for breast tumor imaging based on a linearization approach and the proposed forward model is presented. It is found that the proposed reconstruction algorithm performs well in the phantom experiment, and that the locations of a 5-mm-cube metal target and a 6-mm-cube agar target could be recovered at a target depth of 15 mm using a 32 electrode system. PMID:17405377
Analysis of percent density estimates from digital breast tomosynthesis projection images
NASA Astrophysics Data System (ADS)
Bakic, Predrag R.; Kontos, Despina; Zhang, Cuiping; Yaffe, Martin J.; Maidment, Andrew D. A.
2007-03-01
Women with dense breasts have an increased risk of breast cancer. Breast density is typically measured as the percent density (PD), the percentage of non-fatty (i.e., dense) tissue in breast images. Mammographic PD estimates vary, in part, due to the projective nature of mammograms. Digital breast tomosynthesis (DBT) is a novel radiographic method in which 3D images of the breast are reconstructed from a small number of projection (source) images, acquired at different positions of the x-ray focus. DBT provides superior visualization of breast tissue and has improved sensitivity and specificity as compared to mammography. Our long-term goal is to test the hypothesis that PD obtained from DBT is superior in estimating cancer risk compared with other modalities. As a first step, we have analyzed the PD estimates from DBT source projections since the results would be independent of the reconstruction method. We estimated PD from MLO mammograms (PD M) and from individual DBT projections (PD T). We observed good agreement between PD M and PD T from the central projection images of 40 women. This suggests that variations in breast positioning, dose, and scatter between mammography and DBT do not negatively affect PD estimation. The PD T estimated from individual DBT projections of nine women varied with the angle between the projections. This variation is caused by the 3D arrangement of the breast dense tissue and the acquisition geometry.
Study of breast implant rupture: MRI versus surgical findings.
Vestito, A; Mangieri, F F; Ancona, A; Minervini, C; Perchinunno, V; Rinaldi, S
2012-09-01
This study evaluated the role of breast magnetic resonance (MR) imaging in the selective study breast implant integrity. We retrospectively analysed the signs of breast implant rupture observed at breast MR examinations of 157 implants and determined the sensitivity and specificity of the technique in diagnosing implant rupture by comparing MR data with findings at surgical explantation. The linguine and the salad-oil signs were statistically the most significant signs for diagnosing intracapsular rupture; the presence of siliconomas/seromas outside the capsule and/or in the axillary lymph nodes calls for immediate explantation. In agreement with previous reports, we found a close correlation between imaging signs and findings at explantation. Breast MR imaging can be considered the gold standard in the study of breast implants.
Wang, Cuiyan; Eghtedari, Mohammad; Yang, Wei Tse; Dogan, Basak Erguvan
2018-03-22
Clinical differentiation of atypical breast abscesses from necrotic tumour in premenopausal women is challenging and may delay appropriate therapy. In this case report, we present a 36-year-old woman with signs, symptoms and conventional imaging features of malignancy who underwent breast MRI. On diffusion-weighted imaging (DWI), profoundly low apparent diffusion coefficient values were a distinguishing sign of breast abscess from necrotic breast cancer, and helped manage the patient conservatively. We present a companion case of necrotic breast tumour highlighting significant differences in DWI. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
NASA Astrophysics Data System (ADS)
Cho, Jaedu
The aim of this work is to develop novel breast-specific molecular imaging techniques for management of breast cancer. In this dissertation, we describe two novel molecular imaging approaches for breast cancer management. In Part I, we introduce our multimodal molecular imaging approach for breast cancer therapy monitoring using magnetic resonance imaging and positron emission mammography (MR/PEM). We have focused on the therapy monitoring technique for aggressive cancer molecular subtypes, which is challenging due to time constraint. Breast cancer therapy planning relies on a fast and accurate monitoring of functional and anatomical change. We demonstrate a proof-of-concept of sequential dual-modal magnetic resonance and positron emission mammography (MR/PEM) for the cancer therapy monitoring. We have developed dedicated breast coils with breast compression mechanism equipped with MR-compatible PEM detector heads. We have designed a fiducial marker that allows straightforward image registration of data obtained from MRI and PEM. We propose an optimal multimodal imaging procedure for MR/PEM. In Part II, we have focused on the development of a novel intraoperative near-infrared fluorescence imaging system (NIRF) for image-guided breast cancer surgery. Conventional spectrally-resolved NIRF systems are unable to resolve various NIR fluorescence dyes for the following reasons. First, the fluorescence spectra of viable NIR fluorescence dyes are heavily overlapping. Second, conventional emission-resolved NIRF suffers from a trade-off between the fluence rate and the spectral resolution. Third, the multiple scattering in tissue degrades not only the spatial information but also the spectral contents by the red-shift. We develop a wavelength-swept laser-based NIRF system that can resolve the excitation shift of various NIR fluorescence dyes without substantial loss of the fluence rate. A linear ratiometric model is employed to measure the relative shift of the excitation spectrum of a fluorescence dye.
Breast 3 T-MR imaging: indication for stereotactic vacuum-assisted breast biopsy.
Yamamoto, Nobuko; Yoshizako, Takeshi; Yoshikawa, Kazuaki; Itakura, Masayuki; Maruyama, Riruke; Kitagaki, Hajime
2014-01-01
The purpose of this study was to assess indications for stereotactic vacuum-assisted breast biopsy (SVAB) evaluated by breast 3 T-magnetic resonance (3 T-MR) imaging in patients showing suspicious microcalcifications on mammography and negative ultrasound (US) findings. Fifty-five patients with 55 breast lesions showing suspicious microcalcifications on mammography and negative US findings underwent preoperative 3 T-MR examination including dynamic MR imaging. All patients underwent SVAB within 1 month of MR imaging. The pathological diagnosis of each breast lesion was made by examining tissues obtained by SVAB or radical/partial mastectomy. 3 T-MR imaging findings were evaluated by using the American College of Radiology Breast Imaging Reporting and Data System Atlas (BI-RADS-MRI) and then were correlated with the histopathological findings. When BI-RADS 4 and 5 MR imaging lesions were assumed to be malignant, the usefulness of 3 T-MR imaging was evaluated for diagnosis of impalpable breast lesions by SVAB among lesions with microcalcification detected by mammography and negative US findings. There were 21 malignant lesions, including 5 invasive ductal carcinomas, 16 lesions of ductal carcinoma in situ (DCIS). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 3 T-MR imaging for deciding the indications for SVAB was 90.5%, 97.1%, 95.0%, 94.3%, and 94.5%, respectively. The one-false negative case was a DCIS with small enhancing lesions (0.5 mm). The one false-positive case was ductal adenoma with a linear ductal pattern of enhancement. 3 T-MR imaging may be useful for deciding the indications for SVAB in patients who have breast lesions with microcalcification that are impalpable and are detected by mammography and negative US findings. However, our findings should be considered preliminary and further prospective investigation is required.
Lu, Lee-Jane W.; Nishino, Thomas K.; Khamapirad, Tuenchit; Grady, James J; Leonard, Morton H.; Brunder, Donald G.
2009-01-01
Breast density (the percentage of fibroglandular tissue in the breast) has been suggested to be a useful surrogate marker for breast cancer risk. It is conventionally measured using screen-film mammographic images by a labor intensive histogram segmentation method (HSM). We have adapted and modified the HSM for measuring breast density from raw digital mammograms acquired by full-field digital mammography. Multiple regression model analyses showed that many of the instrument parameters for acquiring the screening mammograms (e.g. breast compression thickness, radiological thickness, radiation dose, compression force, etc) and image pixel intensity statistics of the imaged breasts were strong predictors of the observed threshold values (model R2=0.93) and %density (R2=0.84). The intra-class correlation coefficient of the %-density for duplicate images was estimated to be 0.80, using the regression model-derived threshold values, and 0.94 if estimated directly from the parameter estimates of the %-density prediction regression model. Therefore, with additional research, these mathematical models could be used to compute breast density objectively, automatically bypassing the HSM step, and could greatly facilitate breast cancer research studies. PMID:17671343
Early Diagnosis of Breast Cancer.
Wang, Lulu
2017-07-05
Early-stage cancer detection could reduce breast cancer death rates significantly in the long-term. The most critical point for best prognosis is to identify early-stage cancer cells. Investigators have studied many breast diagnostic approaches, including mammography, magnetic resonance imaging, ultrasound, computerized tomography, positron emission tomography and biopsy. However, these techniques have some limitations such as being expensive, time consuming and not suitable for young women. Developing a high-sensitive and rapid early-stage breast cancer diagnostic method is urgent. In recent years, investigators have paid their attention in the development of biosensors to detect breast cancer using different biomarkers. Apart from biosensors and biomarkers, microwave imaging techniques have also been intensely studied as a promising diagnostic tool for rapid and cost-effective early-stage breast cancer detection. This paper aims to provide an overview on recent important achievements in breast screening methods (particularly on microwave imaging) and breast biomarkers along with biosensors for rapidly diagnosing breast cancer.
Practice guideline for the performance of breast ultrasound elastography.
Lee, Su Hyun; Chang, Jung Min; Cho, Nariya; Koo, Hye Ryoung; Yi, Ann; Kim, Seung Ja; Youk, Ji Hyun; Son, Eun Ju; Choi, Seon Hyeong; Kook, Shin Ho; Chung, Jin; Cha, Eun Suk; Park, Jeong Seon; Jung, Hae Kyoung; Ko, Kyung Hee; Choi, Hye Young; Ryu, Eun Bi; Moon, Woo Kyung
2014-01-01
Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.
Berggren, Karl; Cederström, Björn; Lundqvist, Mats; Fredenberg, Erik
2018-02-01
Digital breast tomosynthesis (DBT) is an emerging tool for breast-cancer screening and diagnostics. The purpose of this study is to present a second-generation photon-counting slit-scanning DBT system and compare it to the first-generation system in terms of geometry and image quality. The study presents the first image-quality measurements on the second-generation system. The geometry of the new system is based on a combined rotational and linear motion, in contrast to a purely rotational scan motion in the first generation. In addition, the calibration routines have been updated. Image quality was measured in the center of the image field in terms of in-slice modulation transfer function (MTF), artifact spread function (ASF), and in-slice detective quantum efficiency (DQE). Images were acquired using a W/Al 29 kVp spectrum at 13 mAs with 2 mm Al additional filtration and reconstructed using simple back-projection. The in-slice 50% MTF was improved in the chest-mammilla direction, going from 3.2 to 3.5 lp/mm, and the zero-frequency DQE increased from 0.71 to 0.77. The MTF and ASF were otherwise found to be on par for the two systems. The new system has reduced in-slice variation of the tomographic angle. The new geometry is less curved, which reduces in-slice tomographic-angle variation, and increases the maximum compression height, making the system accessible for a larger population. The improvements in MTF and DQE were attributed to the updated calibration procedures. We conclude that the second-generation system maintains the key features of the photon-counting system while maintaining or improving image quality and improving the maximum compression height. © 2017 American Association of Physicists in Medicine.
NASA Astrophysics Data System (ADS)
Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako
2007-03-01
The comparison of left and right mammograms is a common technique used by radiologists for the detection and diagnosis of masses. In mammography, computer-aided detection (CAD) schemes using bilateral subtraction technique have been reported. However, in breast ultrasonography, there are no reports on CAD schemes using comparison of left and right breasts. In this study, we propose a scheme of false positive reduction based on bilateral subtraction technique in whole breast ultrasound images. Mass candidate regions are detected by using the information of edge directions. Bilateral breast images are registered with reference to the nipple positions and skin lines. A false positive region is detected based on a comparison of the average gray values of a mass candidate region and a region with the same position and same size as the candidate region in the contralateral breast. In evaluating the effectiveness of the false positive reduction method, three normal and three abnormal bilateral pairs of whole breast images were employed. These abnormal breasts included six masses larger than 5 mm in diameter. The sensitivity was 83% (5/6) with 13.8 (165/12) false positives per breast before applying the proposed reduction method. By applying the method, false positives were reduced to 4.5 (54/12) per breast without removing a true positive region. This preliminary study indicates that the bilateral subtraction technique is effective for improving the performance of a CAD scheme in whole breast ultrasound images.
2004-08-01
or misdiagnosed (4). Therefore, much effort is now directed toward developing alternative breast cancer detection technologies that exploit the...AD Award Number: DAMD17-03-1-0548 TITLE: Non-Invasive Imaging of In Vivo Breast Cancer Tissue Utilizing Metabolically Incorporated Unnatrual Sugars...5. FUNDING NUMBERS Non-Invasive Imaging of In Vivo Breast Cancer Tissue DAMD17-03-1-0548 Utilizing Metabolically Incorporated Unnatrual Sugars 6. A
High-frequency ultrasound imaging for breast cancer biopsy guidance
Cummins, Thomas; Yoon, Changhan; Choi, Hojong; Eliahoo, Payam; Kim, Hyung Ham; Yamashita, Mary W.; Hovanessian-Larsen, Linda J.; Lang, Julie E.; Sener, Stephen F.; Vallone, John; Martin, Sue E.; Kirk Shung, K.
2015-01-01
Abstract. Image-guided core needle biopsy is the current gold standard for breast cancer diagnosis. Microcalcifications, an important radiographic finding on mammography suggestive of early breast cancer such as ductal carcinoma in situ, are usually biopsied under stereotactic guidance. This procedure, however, is uncomfortable for patients and requires the use of ionizing radiation. It would be preferable to biopsy microcalcifications under ultrasound guidance since it is a faster procedure, more comfortable for the patient, and requires no radiation. However, microcalcifications cannot reliably be detected with the current standard ultrasound imaging systems. This study is motivated by the clinical need for real-time high-resolution ultrasound imaging of microcalcifications, so that biopsies can be accurately performed under ultrasound guidance. We have investigated how high-frequency ultrasound imaging can enable visualization of microstructures in ex vivo breast tissue biopsy samples. We generated B-mode images of breast tissue and applied the Nakagami filtering technique to help refine image output so that microcalcifications could be better assessed during ultrasound-guided core biopsies. We describe the preliminary clinical results of high-frequency ultrasound imaging of ex vivo breast biopsy tissue with microcalcifications and without Nakagami filtering and the correlation of these images with the pathology examination by hematoxylin and eosin stain and whole slide digital scanning. PMID:26693167
Generation of 3D synthetic breast tissue
NASA Astrophysics Data System (ADS)
Elangovan, Premkumar; Dance, David R.; Young, Kenneth C.; Wells, Kevin
2016-03-01
Virtual clinical trials are an emergent approach for the rapid evaluation and comparison of various breast imaging technologies and techniques using computer-based modeling tools. A fundamental requirement of this approach for mammography is the use of realistic looking breast anatomy in the studies to produce clinically relevant results. In this work, a biologically inspired approach has been used to simulate realistic synthetic breast phantom blocks for use in virtual clinical trials. A variety of high and low frequency features (including Cooper's ligaments, blood vessels and glandular tissue) have been extracted from clinical digital breast tomosynthesis images and used to simulate synthetic breast blocks. The appearance of the phantom blocks was validated by presenting a selection of simulated 2D and DBT images interleaved with real images to a team of experienced readers for rating using an ROC paradigm. The average areas under the curve for 2D and DBT images were 0.53+/-.04 and 0.55+/-.07 respectively; errors are the standard errors of the mean. The values indicate that the observers had difficulty in differentiating the real images from simulated images. The statistical properties of simulated images of the phantom blocks were evaluated by means of power spectrum analysis. The power spectrum curves for real and simulated images closely match and overlap indicating good agreement.
Lashkari, AmirEhsan; Pak, Fatemeh; Firouzmand, Mohammad
2016-01-01
Breast cancer is the most common type of cancer among women. The important key to treat the breast cancer is early detection of it because according to many pathological studies more than 75% – 80% of all abnormalities are still benign at primary stages; so in recent years, many studies and extensive research done to early detection of breast cancer with higher precision and accuracy. Infra-red breast thermography is an imaging technique based on recording temperature distribution patterns of breast tissue. Compared with breast mammography technique, thermography is more suitable technique because it is noninvasive, non-contact, passive and free ionizing radiation. In this paper, a full automatic high accuracy technique for classification of suspicious areas in thermogram images with the aim of assisting physicians in early detection of breast cancer has been presented. Proposed algorithm consists of four main steps: pre-processing & segmentation, feature extraction, feature selection and classification. At the first step, using full automatic operation, region of interest (ROI) determined and the quality of image improved. Using thresholding and edge detection techniques, both right and left breasts separated from each other. Then relative suspected areas become segmented and image matrix normalized due to the uniqueness of each person's body temperature. At feature extraction stage, 23 features, including statistical, morphological, frequency domain, histogram and Gray Level Co-occurrence Matrix (GLCM) based features are extracted from segmented right and left breast obtained from step 1. To achieve the best features, feature selection methods such as minimum Redundancy and Maximum Relevance (mRMR), Sequential Forward Selection (SFS), Sequential Backward Selection (SBS), Sequential Floating Forward Selection (SFFS), Sequential Floating Backward Selection (SFBS) and Genetic Algorithm (GA) have been used at step 3. Finally to classify and TH labeling procedures, different classifiers such as AdaBoost, Support Vector Machine (SVM), k-Nearest Neighbors (kNN), Naïve Bayes (NB) and probability Neural Network (PNN) are assessed to find the best suitable one. These steps are applied on different thermogram images degrees. The results obtained on native database showed the best and significant performance of the proposed algorithm in comprise to the similar studies. According to experimental results, GA combined with AdaBoost with the mean accuracy of 85.33% and 87.42% on the left and right breast images with 0 degree, GA combined with AdaBoost with mean accuracy of 85.17% on the left breast images with 45 degree and mRMR combined with AdaBoost with mean accuracy of 85.15% on the right breast images with 45 degree, and also GA combined with AdaBoost with a mean accuracy of 84.67% and 86.21%, on the left and right breast images with 90 degree, are the best combinations of feature selection and classifier for evaluation of breast images. PMID:27014608
Mastanduno, Michael A.; El-Ghussein, Fadi; Jiang, Shudong; DiFlorio-Alexander, Roberta; Junqing, Xu; Hong, Yin; Pogue, Brian W.; Paulsen, Keith D.
2016-01-01
Rationale and Objectives Near-infrared spectroscopy (NIRS) of breast can provide functional information on the vascular and structural compartments of tissues in regions identified during simultaneous magnetic resonance imaging (MRI). NIRS can be acquired during dynamic contrast-enhanced MRI (DCE-MRI) to accomplish image-guided spectroscopy of the enhancing regions, potentially increasing the diagnostic specificity of the examination and reducing the number of biopsies performed as a result of inconclusive MRI breast imaging studies. Materials and Methods We combine synergistic attributes of concurrent DCE-MRI and NIRS with a new design of the clinical NIRS breast interface that couples to a standard MR breast coil and allows imaging of variable breast sizes. Spectral information from healthy volunteers and cancer patients is recovered, providing molecular information in regions defined by the segmented MR image volume. Results The new coupling system significantly improves examination utility by allowing improved coupling of the NIR fibers to breasts of all cup sizes and lesion locations. This improvement is demonstrated over a range of breast sizes (cup size A through D) and normal tissue heterogeneity using a group of eight healthy volunteers and two cancer patients. Lesions located in the axillary region and medial-posterior breast are now accessible to NIRS optodes. Reconstructed images were found to have biologically plausible hemoglobin content, oxygen saturation, and water and lipid fractions. Conclusions In summary, a new NIRS/MRI breast interface was developed to accommodate the variation in breast sizes and lesion locations that can be expected in clinical practice. DCE-MRI–guided NIRS quantifies total hemoglobin, oxygenation, and scattering in MR-enhancing regions, increasing the diagnostic information acquired from MR examinations. PMID:24439327
Introducing DeBRa: a detailed breast model for radiological studies
NASA Astrophysics Data System (ADS)
Ma, Andy K. W.; Gunn, Spencer; Darambara, Dimitra G.
2009-07-01
Currently, x-ray mammography is the method of choice in breast cancer screening programmes. As the mammography technology moves from 2D imaging modalities to 3D, conventional computational phantoms do not have sufficient detail to support the studies of these advanced imaging systems. Studies of these 3D imaging systems call for a realistic and sophisticated computational model of the breast. DeBRa (Detailed Breast model for Radiological studies) is the most advanced, detailed, 3D computational model of the breast developed recently for breast imaging studies. A DeBRa phantom can be constructed to model a compressed breast, as in film/screen, digital mammography and digital breast tomosynthesis studies, or a non-compressed breast as in positron emission mammography and breast CT studies. Both the cranial-caudal and mediolateral oblique views can be modelled. The anatomical details inside the phantom include the lactiferous duct system, the Cooper ligaments and the pectoral muscle. The fibroglandular tissues are also modelled realistically. In addition, abnormalities such as microcalcifications, irregular tumours and spiculated tumours are inserted into the phantom. Existing sophisticated breast models require specialized simulation codes. Unlike its predecessors, DeBRa has elemental compositions and densities incorporated into its voxels including those of the explicitly modelled anatomical structures and the noise-like fibroglandular tissues. The voxel dimensions are specified as needed by any study and the microcalcifications are embedded into the voxels so that the microcalcification sizes are not limited by the voxel dimensions. Therefore, DeBRa works with general-purpose Monte Carlo codes. Furthermore, general-purpose Monte Carlo codes allow different types of imaging modalities and detector characteristics to be simulated with ease. DeBRa is a versatile and multipurpose model specifically designed for both x-ray and γ-ray imaging studies.
Pignatti, Marco; Mantovani, Francesca; Bertelli, Luca; Barbieri, Andrea; Pacchioni, Lucrezia; Loschi, Pietro; De Santis, Giorgio
2013-08-01
Use of silicone expanders and implants is the most common breast reconstruction technique after mastectomy. Postmastectomy patients often need echocardiographic monitoring of potential cardiotoxicity induced by cancer chemotherapy. The impairment of the echocardiographic acoustic window caused by silicone implants for breast augmentation has been reported. This study investigates whether the echocardiographic image quality was impaired in women reconstructed with silicone expanders and implants. The records of 44 consecutive women who underwent echocardiographic follow-up after breast reconstruction with expanders and implants at the authors' institution from January of 2000 to August of 2012 were reviewed. The population was divided into a study group (left or bilateral breast expanders/implants, n=30) and a control group (right breast expanders/implants, n=14). The impact of breast expanders/implants on echocardiographic image quality was tested (analysis of covariance model). Patients with a breast expander/implant (left or bilateral and right breast expanders/implants) were included. The mean volume of the breast devices was 353.2±125.5 cc. The quality of the echocardiographic images was good or sufficient in the control group; in the study group, it was judged as adequate in only 50 percent of cases (15 patients) and inadequate in the remaining 15 patients (p<0.001). At multivariable analysis, a persistent relationship between device position (left versus right) and image quality (p=0.001) was shown, independent from other factors. Silicone expanders and implants in postmastectomy left breast reconstruction considerably reduce the image quality of echocardiography. This may have important clinical implications, given the need for periodic echocardiographic surveillance before and during chemotherapy. Therapeutic, III.
NASA Astrophysics Data System (ADS)
Kontos, Despina; Xing, Ye; Bakic, Predrag R.; Conant, Emily F.; Maidment, Andrew D. A.
2010-03-01
We performed a study to compare methods for volumetric breast density estimation in digital mammography (DM) and magnetic resonance imaging (MRI) for a high-risk population of women. DM and MRI images of the unaffected breast from 32 women with recently detected abnormalities and/or previously diagnosed breast cancer (age range 31-78 yrs, mean 50.3 yrs) were retrospectively analyzed. DM images were analyzed using QuantraTM (Hologic Inc). The MRI images were analyzed using a fuzzy-C-means segmentation algorithm on the T1 map. Both methods were compared to Cumulus (Univ. Toronto). Volumetric breast density estimates from DM and MRI are highly correlated (r=0.90, p<=0.001). The correlation between the volumetric and the area-based density measures is lower and depends on the training background of the Cumulus software user (r=0.73-84, p<=0.001). In terms of absolute values, MRI provides the lowest volumetric estimates (mean=14.63%), followed by the DM volumetric (mean=22.72%) and area-based measures (mean=29.35%). The MRI estimates of the fibroglandular volume are statistically significantly lower than the DM estimates for women with very low-density breasts (p<=0.001). We attribute these differences to potential partial volume effects in MRI and differences in the computational aspects of the image analysis methods in MRI and DM. The good correlation between the volumetric and the area-based measures, shown to correlate with breast cancer risk, suggests that both DM and MRI volumetric breast density measures can aid in breast cancer risk assessment. Further work is underway to fully-investigate the association between volumetric breast density measures and breast cancer risk.
Association between mammogram density and background parenchymal enhancement of breast MRI
NASA Astrophysics Data System (ADS)
Aghaei, Faranak; Danala, Gopichandh; Wang, Yunzhi; Zarafshani, Ali; Qian, Wei; Liu, Hong; Zheng, Bin
2018-02-01
Breast density has been widely considered as an important risk factor for breast cancer. The purpose of this study is to examine the association between mammogram density results and background parenchymal enhancement (BPE) of breast MRI. A dataset involving breast MR images was acquired from 65 high-risk women. Based on mammography density (BIRADS) results, the dataset was divided into two groups of low and high breast density cases. The Low-Density group has 15 cases with mammographic density (BIRADS 1 and 2), while the High-density group includes 50 cases, which were rated by radiologists as mammographic density BIRADS 3 and 4. A computer-aided detection (CAD) scheme was applied to segment and register breast regions depicted on sequential images of breast MRI scans. CAD scheme computed 20 global BPE features from the entire two breast regions, separately from the left and right breast region, as well as from the bilateral difference between left and right breast regions. An image feature selection method namely, CFS method, was applied to remove the most redundant features and select optimal features from the initial feature pool. Then, a logistic regression classifier was built using the optimal features to predict the mammogram density from the BPE features. Using a leave-one-case-out validation method, the classifier yields the accuracy of 82% and area under ROC curve, AUC=0.81+/-0.09. Also, the box-plot based analysis shows a negative association between mammogram density results and BPE features in the MRI images. This study demonstrated a negative association between mammogram density and BPE of breast MRI images.
Uematsu, T; Kasami, M; Uchida, Y; Sanuki, J; Kimura, K; Tanaka, K; Takahashi, K
2007-06-01
Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed. To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB. Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined. CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm). CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.
Sinha, Sumedha P; Goodsitt, Mitchell M; Roubidoux, Marilyn A; Booi, Rebecca C; LeCarpentier, Gerald L; Lashbrook, Christine R; Thomenius, Kai E; Chalek, Carl L; Carson, Paul L
2007-05-01
We are developing an automated ultrasound imaging-mammography system wherein a digital mammography unit has been augmented with a motorized ultrasound transducer carriage above a special compression paddle. Challenges of this system are acquiring complete coverage of the breast and minimizing motion. We assessed these problems and investigated methods to increase coverage and stabilize the compressed breast. Visual tracings of the breast-to-paddle contact area and breast periphery were made for 10 patients to estimate coverage area. Various motion artifacts were evaluated in 6 patients. Nine materials were tested for coupling the paddle to the breast. Fourteen substances were tested for coupling the transducer to the paddle in lateral-to-medial and medial-to-lateral views and filling the gap between the peripheral breast and paddle. In-house image registration software was used to register adjacent ultrasound sweeps. The average breast contact area was 56%. The average percentage of the peripheral air gap filled with ultrasound gel was 61%. Shallow patient breathing proved equivalent to breath holding, whereas speech and sudden breathing caused unacceptable artifacts. An adhesive spray that preserves image quality was found to be best for coupling the breast to the paddle and minimizing motion. A highly viscous ultrasound gel proved most effective for coupling the transducer to the paddle for lateral-to-medial and medial-to-lateral views and for edge fill-in. The challenges of automated ultrasound scanning in a multimodality breast imaging system have been addressed by developing methods to fill in peripheral gaps, minimize patient motion, and register and reconstruct multisweep ultrasound image volumes.
Stereotactic Image-Guided Navigation During Breast Reconstruction in Patients With Breast Cancer
2017-04-12
Ductal Breast Carcinoma in Situ; Lobular Breast Carcinoma in Situ; Recurrent Breast Cancer; Stage IA Breast Cancer; Stage IB Breast Cancer; Stage II Breast Cancer; Stage IIIA Breast Cancer; Stage IIIB Breast Cancer; Stage IIIC Breast Cancer; Stage IV Breast Cancer
Surgery to Reduce the Risk of Breast Cancer
... breast cancer screening (also called enhanced screening). For example, they may have yearly mammograms and yearly magnetic resonance imaging (MRI) screening—with these tests staggered so that the breasts are imaged every ...
Neutrosophic segmentation of breast lesions for dedicated breast CT
NASA Astrophysics Data System (ADS)
Lee, Juhun; Nishikawa, Robert M.; Reiser, Ingrid; Boone, John M.
2017-03-01
We proposed the neutrosophic approach for segmenting breast lesions in breast Computer Tomography (bCT) images. The neutrosophic set (NS) considers the nature and properties of neutrality (or indeterminacy), which is neither true nor false. We considered the image noise as an indeterminate component, while treating the breast lesion and other breast areas as true and false components. We first transformed the image into the NS domain. Each voxel in the image can be described as its membership in True, Indeterminate, and False sets. Operations α-mean, β-enhancement, and γ-plateau iteratively smooth and contrast-enhance the image to reduce the noise level of the true set. Once the true image no longer changes, we applied one existing algorithm for bCT images, the RGI segmentation, on the resulting image to segment the breast lesions. We compared the segmentation performance of the proposed method (named as NS-RGI) to that of the regular RGI segmentation. We used a total of 122 breast lesions (44 benign, 78 malignant) of 123 non-contrasted bCT cases. We measured the segmentation performances of the NS-RGI and the RGI using the DICE coefficient. The average DICE value of the NS-RGI was 0.82 (STD: 0.09), while that of the RGI was 0.8 (STD: 0.12). The difference between the two DICE values was statistically significant (paired t test, p-value = 0.0007). We conducted a subsequent feature analysis on the resulting segmentations. The classifier performance for the NS-RGI (AUC = 0.8) improved over that of the RGI (AUC = 0.69, p-value = 0.006).
Fully automated chest wall line segmentation in breast MRI by using context information
NASA Astrophysics Data System (ADS)
Wu, Shandong; Weinstein, Susan P.; Conant, Emily F.; Localio, A. Russell; Schnall, Mitchell D.; Kontos, Despina
2012-03-01
Breast MRI has emerged as an effective modality for the clinical management of breast cancer. Evidence suggests that computer-aided applications can further improve the diagnostic accuracy of breast MRI. A critical and challenging first step for automated breast MRI analysis, is to separate the breast as an organ from the chest wall. Manual segmentation or user-assisted interactive tools are inefficient, tedious, and error-prone, which is prohibitively impractical for processing large amounts of data from clinical trials. To address this challenge, we developed a fully automated and robust computerized segmentation method that intensively utilizes context information of breast MR imaging and the breast tissue's morphological characteristics to accurately delineate the breast and chest wall boundary. A critical component is the joint application of anisotropic diffusion and bilateral image filtering to enhance the edge that corresponds to the chest wall line (CWL) and to reduce the effect of adjacent non-CWL tissues. A CWL voting algorithm is proposed based on CWL candidates yielded from multiple sequential MRI slices, in which a CWL representative is generated and used through a dynamic time warping (DTW) algorithm to filter out inferior candidates, leaving the optimal one. Our method is validated by a representative dataset of 20 3D unilateral breast MRI scans that span the full range of the American College of Radiology (ACR) Breast Imaging Reporting and Data System (BI-RADS) fibroglandular density categorization. A promising performance (average overlay percentage of 89.33%) is observed when the automated segmentation is compared to manually segmented ground truth obtained by an experienced breast imaging radiologist. The automated method runs time-efficiently at ~3 minutes for each breast MR image set (28 slices).
Modeling digital breast tomosynthesis imaging systems for optimization studies
NASA Astrophysics Data System (ADS)
Lau, Beverly Amy
Digital breast tomosynthesis (DBT) is a new imaging modality for breast imaging. In tomosynthesis, multiple images of the compressed breast are acquired at different angles, and the projection view images are reconstructed to yield images of slices through the breast. One of the main problems to be addressed in the development of DBT is the optimal parameter settings to obtain images ideal for detection of cancer. Since it would be unethical to irradiate women multiple times to explore potentially optimum geometries for tomosynthesis, it is ideal to use a computer simulation to generate projection images. Existing tomosynthesis models have modeled scatter and detector without accounting for oblique angles of incidence that tomosynthesis introduces. Moreover, these models frequently use geometry-specific physical factors measured from real systems, which severely limits the robustness of their algorithms for optimization. The goal of this dissertation was to design the framework for a computer simulation of tomosynthesis that would produce images that are sensitive to changes in acquisition parameters, so an optimization study would be feasible. A computer physics simulation of the tomosynthesis system was developed. The x-ray source was modeled as a polychromatic spectrum based on published spectral data, and inverse-square law was applied. Scatter was applied using a convolution method with angle-dependent scatter point spread functions (sPSFs), followed by scaling using an angle-dependent scatter-to-primary ratio (SPR). Monte Carlo simulations were used to generate sPSFs for a 5-cm breast with a 1-cm air gap. Detector effects were included through geometric propagation of the image onto layers of the detector, which were blurred using depth-dependent detector point-spread functions (PRFs). Depth-dependent PRFs were calculated every 5-microns through a 200-micron thick CsI detector using Monte Carlo simulations. Electronic noise was added as Gaussian noise as a last step of the model. The sPSFs and detector PRFs were verified to match published data, and noise power spectrum (NPS) from simulated flat field images were shown to match empirically measured data from a digital mammography unit. A novel anthropomorphic software breast phantom was developed for 3D imaging simulation. Projection view images of the phantom were shown to have similar structure as real breasts in the spatial frequency domain, using the power-law exponent beta to quantify tissue complexity. The physics simulation and computer breast phantom were used together, following methods from a published study with real tomosynthesis images of real breasts. The simulation model and 3D numerical breast phantoms were able to reproduce the trends in the experimental data. This result demonstrates the ability of the tomosynthesis physics model to generate images sensitive to changes in acquisition parameters.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de
Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating andmore » applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at positions closer to attenuating hardware structures of the RF coil. The position accuracy of the RF coil on the patient table when using the positioning frame was determined well below 1 mm for all three spatial dimensions. This ensures perfect position match between the RF coil and its three-dimensional attenuation template during the PET data reconstruction process. When applying the CT-based AC of the RF coil, the global attenuation bias was mostly compensated to ±0.5% across the entire breast imaging volume. The patient study revealed high quality MR, PET, and combined PET/MR imaging of breast cancer. Quantitative activity measurements in all 11 breast cancer lesions of the ten patients resulted in increased mean difference values of SUV{sub max} 11.8% (minimum 3.2%; maximum 23.2%) between nonAC images and images when AC of the RF breast coil was applied. This supports the quantitative results of the phantom study as well as successful attenuation correction of the RF coil. Conclusions: A 16-channel breast RF coil was designed for optimized MR imaging performance and PET transparency and was successfully integrated with its dedicated attenuation correction template into a whole-body PET/MR system. Systematic PET/MR imaging evaluation with phantoms and an initial study on patients with breast cancer provided excellent MR and PET image quality and accurate PET quantification.« less
Fazzino, Tera L; Hunter, Rebecca Clausius; Sporn, Nora; Christifano, Danielle N; Befort, Christie A
2017-03-01
Obesity and weight gain after breast cancer treatment are common among survivors, yet the relationship between weight and body image has received little attention. The purpose of the current study was to examine the relationship between current body mass index, weight gain since diagnosis, and largest weight fluctuation in adulthood with six dimensions of body image among overweight/obese breast cancer survivors. The current study used data obtained from a weight control trial with 210 rural overweight/obese breast cancer survivors. Using data collected at baseline, multiple regression models were constructed to examine the relative association of the three weight variables with breast cancer-specific dimensions of body image while controlling for demographic characteristics and cancer treatment-related variables. Largest weight fluctuation in adulthood significantly predicted overall body image (p = 0.01) and was associated with the three socially oriented dimensions of body image: social activity restriction, embarrassment about appearance, and sexuality (all ps = 0.01). Weight gain since diagnosis approached statistical significance in predicting overall body image (p = 0.05) and was associated with embarrassment about appearance (p = 0.03). Current body mass index was not significantly associated with overall body image when controlling for the other weight variables (p = 0.07) and was negatively associated with social activity restriction (p = 0.01) and sexuality (p = 0.01). Obese breast cancer survivors with a history of a large weight fluctuation in adulthood may be prone to poorer breast cancer-specific body image several years after treatment. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Breast EIT using a new projected image reconstruction method with multi-frequency measurements.
Lee, Eunjung; Ts, Munkh-Erdene; Seo, Jin Keun; Woo, Eung Je
2012-05-01
We propose a new method to produce admittivity images of the breast for the diagnosis of breast cancer using electrical impedance tomography(EIT). Considering the anatomical structure of the breast, we designed an electrode configuration where current-injection and voltage-sensing electrodes are separated in such a way that internal current pathways are approximately along the tangential direction of an array of voltage-sensing electrodes. Unlike conventional EIT imaging methods where the number of injected currents is maximized to increase the total amount of measured data, current is injected only twice between two pairs of current-injection electrodes attached along the circumferential side of the breast. For each current injection, the induced voltages are measured from the front surface of the breast using as many voltage-sensing electrodes as possible. Although this electrode configurational lows us to measure induced voltages only on the front surface of the breast,they are more sensitive to an anomaly inside the breast since such an injected current tends to produce a more uniform internal current density distribution. Furthermore, the sensitivity of a measured boundary voltage between two equipotential lines on the front surface of the breast is improved since those equipotential lines are perpendicular to the primary direction of internal current streamlines. One should note that this novel data collection method is different from those of other frontal plane techniques such as the x-ray projection and T-scan imaging methods because we do not get any data on the plane that is perpendicular to the current flow. To reconstruct admittivity images using two measured voltage data sets, a new projected image reconstruction algorithm is developed. Numerical simulations demonstrate the frequency-difference EIT imaging of the breast. The results show that the new method is promising to accurately detect and localize small anomalies inside the breast.
In Vivo Measurement of Drug Efficacy in Breast Cancer
2015-10-01
treatment. 15. SUBJECT TERMS Breast Cancer, Intravital Imaging , Nanoparticles, Pharmacokinetics/ Pharmacodynamics, Chemotherapy, Drug Distribution 16...drug testing in year 2 of the project. 2. KEYWORDS Breast Cancer, Intravital Imaging , Nanoparticles, Pharmacokinetics/ Pharmacodynamics, Chemotherapy...left side of the diagram displays the overall proposed algorithm for analyzing intravital images and determining drug concentration. This algorithm is
Tight-frame based iterative image reconstruction for spectral breast CT
Zhao, Bo; Gao, Hao; Ding, Huanjun; Molloi, Sabee
2013-01-01
Purpose: To investigate tight-frame based iterative reconstruction (TFIR) technique for spectral breast computed tomography (CT) using fewer projections while achieving greater image quality. Methods: The experimental data were acquired with a fan-beam breast CT system based on a cadmium zinc telluride photon-counting detector. The images were reconstructed with a varying number of projections using the TFIR and filtered backprojection (FBP) techniques. The image quality between these two techniques was evaluated. The image's spatial resolution was evaluated using a high-resolution phantom, and the contrast to noise ratio (CNR) was evaluated using a postmortem breast sample. The postmortem breast samples were decomposed into water, lipid, and protein contents based on images reconstructed from TFIR with 204 projections and FBP with 614 projections. The volumetric fractions of water, lipid, and protein from the image-based measurements in both TFIR and FBP were compared to the chemical analysis. Results: The spatial resolution and CNR were comparable for the images reconstructed by TFIR with 204 projections and FBP with 614 projections. Both reconstruction techniques provided accurate quantification of water, lipid, and protein composition of the breast tissue when compared with data from the reference standard chemical analysis. Conclusions: Accurate breast tissue decomposition can be done with three fold fewer projection images by the TFIR technique without any reduction in image spatial resolution and CNR. This can result in a two-third reduction of the patient dose in a multislit and multislice spiral CT system in addition to the reduced scanning time in this system. PMID:23464320
Anatomical background noise power spectrum in differential phase contrast breast images
NASA Astrophysics Data System (ADS)
Garrett, John; Ge, Yongshuai; Li, Ke; Chen, Guang-Hong
2015-03-01
In x-ray breast imaging, the anatomical noise background of the breast has a significant impact on the detection of lesions and other features of interest. This anatomical noise is typically characterized by a parameter, β, which describes a power law dependence of anatomical noise on spatial frequency (the shape of the anatomical noise power spectrum). Large values of β have been shown to reduce human detection performance, and in conventional mammography typical values of β are around 3.2. Recently, x-ray differential phase contrast (DPC) and the associated dark field imaging methods have received considerable attention as possible supplements to absorption imaging for breast cancer diagnosis. However, the impact of these additional contrast mechanisms on lesion detection is not yet well understood. In order to better understand the utility of these new methods, we measured the β indices for absorption, DPC, and dark field images in 15 cadaver breast specimens using a benchtop DPC imaging system. We found that the measured β value for absorption was consistent with the literature for mammographic acquisitions (β = 3.61±0.49), but that both DPC and dark field images had much lower values of β (β = 2.54±0.75 for DPC and β = 1.44±0.49 for dark field). In addition, visual inspection showed greatly reduced anatomical background in both DPC and dark field images. These promising results suggest that DPC and dark field imaging may help provide improved lesion detection in breast imaging, particularly for those patients with dense breasts, in whom anatomical noise is a major limiting factor in identifying malignancies.
Compound Radar Approach for Breast Imaging.
Byrne, Dallan; Sarafianou, Mantalena; Craddock, Ian J
2017-01-01
Multistatic radar apertures record scattering at a number of receivers when the target is illuminated by a single transmitter, providing more scattering information than its monostatic counterpart per transmission angle. This paper considers the well-known problem of detecting tumor targets within breast phantoms using multistatic radar. To accurately image potentially cancerous targets size within the breast, a significant number of multistatic channels are required in order to adequately calibrate-out unwanted skin reflections, increase the immunity to clutter, and increase the dynamic range of a breast radar imaging system. However, increasing the density of antennas within a physical array is inevitably limited by the geometry of the antenna elements designed to operate with biological tissues at microwave frequencies. A novel compound imaging approach is presented to overcome these physical constraints and improve the imaging capabilities of a multistatic radar imaging modality for breast scanning applications. The number of transmit-receive (TX-RX) paths available for imaging are increased by performing a number of breast scans with varying array positions. A skin calibration method is presented to reduce the influence of skin reflections from each channel. Calibrated signals are applied to receive a beamforming method, compounding the data from each scan to produce a microwave radar breast profile. The proposed imaging method is evaluated with experimental data obtained from constructed phantoms of varying complexity, skin contour asymmetries, and challenging tumor positions and sizes. For each imaging scenario outlined in this study, the proposed compound imaging technique improves skin calibration, clearly detects small targets, and substantially reduces the level of undesirable clutter within the profile.
NASA Astrophysics Data System (ADS)
Garrett, John; Li, Yinsheng; Li, Ke; Chen, Guang-Hong
2017-03-01
Digital breast tomosynthesis (DBT) is a three dimensional (3D) breast imaging modality in which projections are acquired over a limited angular span around the compressed breast and reconstructed into image slices parallel to the detector. DBT has been shown to help alleviate the breast tissue overlapping issues of two dimensional (2D) mammography. Since the overlapping tissues may simulate cancer masses or obscure true cancers, this improvement is critically important for improved breast cancer screening and diagnosis. In this work, a model-based image reconstruction method is presented to show that spatial resolution in DBT volumes can be maintained while dose is reduced using the presented method when compared to that of a state-of-the-art commercial reconstruction technique. Spatial resolution was measured in phantom images and subjectively in a clinical dataset. Noise characteristics were explored in a cadaver study. In both the quantitative and subjective results the image sharpness was maintained and overall image quality was maintained at reduced doses when the model-based iterative reconstruction was used to reconstruct the volumes.
Review of optical breast imaging and spectroscopy
NASA Astrophysics Data System (ADS)
Grosenick, Dirk; Rinneberg, Herbert; Cubeddu, Rinaldo; Taroni, Paola
2016-09-01
Diffuse optical imaging and spectroscopy of the female breast is an area of active research. We review the present status of this field and discuss the broad range of methodologies and applications. Starting with a brief overview on breast physiology, the remodeling of vasculature and extracellular matrix caused by solid tumors is highlighted that is relevant for contrast in optical imaging. Then, the various instrumental techniques and the related methods of data analysis and image generation are described and compared including multimodality instrumentation, fluorescence mammography, broadband spectroscopy, and diffuse correlation spectroscopy. We review the clinical results on functional properties of malignant and benign breast lesions compared to host tissue and discuss the various methods to improve contrast between healthy and diseased tissue, such as enhanced spectroscopic information, dynamic variations of functional properties, pharmacokinetics of extrinsic contrast agents, including the enhanced permeability and retention effect. We discuss research on monitoring neoadjuvant chemotherapy and on breast cancer risk assessment as potential clinical applications of optical breast imaging and spectroscopy. Moreover, we consider new experimental approaches, such as photoacoustic imaging and long-wavelength tissue spectroscopy.
Patterns of Breast Magnetic Resonance Imaging Use in Community Practice
Wernli, Karen J.; DeMartini, Wendy B.; Ichikawa, Laura; Lehman, Constance D.; Onega, Tracy; Kerlikowske, Karla; Henderson, Louise M.; Geller, Berta M.; Hofmann, Mike; Yankaskas, Bonnie C.
2014-01-01
Importance Breast magnetic resonance imaging (MRI) is increasingly used for breast cancer screening, diagnostic evaluation, and surveillance However, we lack data on national patterns of breast MRI use in community practice. Objective To describe 2005–2009 patterns of breast magnetic resonance imaging (MRI) use in U.S. community practice. Design Observational cohort study Setting Data collected from 2005–2009 on breast MRI and mammography from five national Breast Cancer Surveillance Consortium registries. Participants Data included 8931 breast MRI examinations and 1,288,924 screening mammograms from women aged 18–79 years. Main measures We calculated the rate of breast MRI examinations per 1000 women with breast imaging within the same year and described the clinical indications for the breast MRI examinations by year and age. We compared women screened with breast MRI to women screened with mammography alone for patient characteristics and lifetime breast cancer risk. Results The overall rate of breast MRI from 2005 through 2009 nearly tripled from 4.2 to 11.5 examinations per 1000 women with the most rapid rise from 2005–2007 (p=0.02). The most common clinical indication was diagnostic evaluation (40.3%), followed by screening (31.7%). Compared to women who received screening mammography alone, women who underwent screening breast MRI were more likely to be <50 years, white non-Hispanic, nulliparous, and have extremely dense breast tissue, a family history of breast cancer, and a personal history of breast cancer. The proportion of women screened by breast MRI at high lifetime risk for breast cancer (>20%) increased during the study period from 9% in 2005 to 29% in 2009. Conclusions and relevance Use of breast MRI for screening in high-risk women is increasing. However, our findings suggest there is a need to improve appropriate utilization, including among women who may benefit from screening breast MRI. PMID:24247555
Comparison of sound speed measurements on two different ultrasound tomography devices
NASA Astrophysics Data System (ADS)
Sak, Mark; Duric, Neb; Littrup, Peter; Bey-Knight, Lisa; Sherman, Mark; Gierach, Gretchen; Malyarenko, Antonina
2014-03-01
Ultrasound tomography (UST) employs sound waves to produce three-dimensional images of breast tissue and precisely measures the attenuation of sound speed secondary to breast tissue composition. High breast density is a strong breast cancer risk factor and sound speed is directly proportional to breast density. UST provides a quantitative measure of breast density based on three-dimensional imaging without compression, thereby overcoming the shortcomings of many other imaging modalities. The quantitative nature of the UST breast density measures are tied to an external standard, so sound speed measurement in breast tissue should be independent of specific hardware. The work presented here compares breast sound speed measurement obtained with two different UST devices. The Computerized Ultrasound Risk Evaluation (CURE) system located at the Karmanos Cancer Institute in Detroit, Michigan was recently replaced with the SoftVue ultrasound tomographic device. Ongoing clinical trials have used images generated from both sets of hardware, so maintaining consistency in sound speed measurements is important. During an overlap period when both systems were in the same exam room, a total of 12 patients had one or both of their breasts imaged on both systems on the same day. There were 22 sound speed scans analyzed from each system and the average breast sound speeds were compared. Images were either reconstructed using saved raw data (for both CURE and SoftVue) or were created during the image acquisition (saved in DICOM format for SoftVue scans only). The sound speed measurements from each system were strongly and positively correlated with each other. The average difference in sound speed between the two sets of data was on the order of 1-2 m/s and this result was not statistically significant. The only sets of images that showed a statistical difference were the DICOM images created during the SoftVue scan compared to the SoftVue images reconstructed from the raw data. However, the discrepancy between the sound speed values could be easily handled by uniformly increasing the DICOM sound speed by approximately 0.5 m/s. These results suggest that there is no fundamental difference in sound speed measurement for the two systems and support combining data generated with these instruments in future studies.
Breast-Dedicated Radionuclide Imaging Systems.
Hsu, David F C; Freese, David L; Levin, Craig S
2016-02-01
Breast-dedicated radionuclide imaging systems show promise for increasing clinical sensitivity for breast cancer while minimizing patient dose and cost. We present several breast-dedicated coincidence-photon and single-photon camera designs that have been described in the literature and examine their intrinsic performance, clinical relevance, and impact. Recent tracer development is mentioned, results from recent clinical tests are summarized, and potential areas for improvement are highlighted. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
2013-10-01
MAMMOGRAM 5 OTHER BREAST IMAGING TEST (E.G., MRI , ULTRASOUND) 6 THEMOGRAPHY 7 NOTHING 8 DK/REF PROBE: ANYTHING ELSE? IF NECESSARY: JUST THE...SKIP IF HOWCHECK = 5] Have you ever had any other breast imaging procedure designed to detect breast cancer (for example, an MRI or ultrasound? 1 YES...SELECT ALL THAT APPLY) 1 Another mammogram 2 Ultrasound of the breast 3 MRI of the breast 4 OTHER [specify:] 31 5 NONE 6 DK/REF {Q: ADDSURG
Breast and Gynecologic Cancer | Division of Cancer Prevention
[[{"fid":"184","view_mode":"default","fields":{"format":"default","field_file_image_alt_text[und][0][value]":"Breast and Gynecologic Cancer Research Group Homepage Logo","field_file_image_title_text[und][0][value]":"Breast and Gynecologic Cancer Research Group Homepage Logo","field_folder[und]":"15"},"type":"media","attributes":{"alt":"Breast and Gynecologic Cancer Research
Image segmentation and 3D visualization for MRI mammography
NASA Astrophysics Data System (ADS)
Li, Lihua; Chu, Yong; Salem, Angela F.; Clark, Robert A.
2002-05-01
MRI mammography has a number of advantages, including the tomographic, and therefore three-dimensional (3-D) nature, of the images. It allows the application of MRI mammography to breasts with dense tissue, post operative scarring, and silicon implants. However, due to the vast quantity of images and subtlety of difference in MR sequence, there is a need for reliable computer diagnosis to reduce the radiologist's workload. The purpose of this work was to develop automatic breast/tissue segmentation and visualization algorithms to aid physicians in detecting and observing abnormalities in breast. Two segmentation algorithms were developed: one for breast segmentation, the other for glandular tissue segmentation. In breast segmentation, the MRI image is first segmented using an adaptive growing clustering method. Two tracing algorithms were then developed to refine the breast air and chest wall boundaries of breast. The glandular tissue segmentation was performed using an adaptive thresholding method, in which the threshold value was spatially adaptive using a sliding window. The 3D visualization of the segmented 2D slices of MRI mammography was implemented under IDL environment. The breast and glandular tissue rendering, slicing and animation were displayed.
How Can Advanced Imaging Be Used to Mitigate Potential Breast Cancer Overdiagnosis?
Rahbar, Habib; McDonald, Elizabeth S.; Lee, Janie M.; Partridge, Savannah C.; Lee, Christoph I.
2016-01-01
Radiologists, as administrators and interpreters of screening mammography, are considered by some to be major contributors to the potential harms of screening, including overdiagnosis and overtreatment. In this article, we outline current efforts within the breast imaging community towards mitigating screening harms, including the widespread adoption of tomosynthesis and potentially adjusting screening frequency and thresholds for image-guided breast biopsy. However, the emerging field of breast radiomics may offer the greatest promise for reducing overdiagnosis by identifying imaging-based biomarkers strongly associated with tumor biology and, therefore, helping prevent the harms of unnecessary treatment for indolent cancers. PMID:27017136
NASA Astrophysics Data System (ADS)
Crotty, Dominic J.; Brady, Samuel L.; Jackson, D'Vone C.; Toncheva, Greta I.; Anderson, Colin E.; Yoshizumi, Terry T.; Tornai, Martin P.
2010-04-01
A dual modality SPECT-CT prototype dedicated to uncompressed breast imaging (mammotomography) has been developed. The CT subsystem incorporates an ultra-thick K-edge filtration technique producing a quasi-monochromatic x-ray cone beam to optimize the dose efficiency for uncompressed breast tomography. We characterize the absorbed dose to the breast under normal tomographic cone beam image acquisition protocols using both TLD measurements and ionization chamber-calibrated radiochromic film. Geometric and anthropomorphic breast phantoms are filled with 1000mL of water and oil to simulate different breast compositions and varying object shapes having density bounds of 100% glandular and fatty breast compositions, respectively. Doses to the water filled geometric and anthropomorphic breast phantoms for a tomographic scan range from 1.3-7.3mGy and 1.7-6.3mGy, respectively, with a mean whole-breast dose of 4.5mGy for the water-filled anthropomorphic phantom. Measured dose distribution trends indicate lower doses in the center of the breast phantoms towards the chest wall along with higher doses near the peripheries and nipple regions. Measured doses to the oil-filled phantoms are consistently lower across all volume shapes (mean dose, 3.8mGy for the anthropomorphic breast). Results agree with Monte Carlo dose estimates generated for uncompressed breast imaging and illustrate the advantages of using the novel K-edge filtered beam to minimize absorbed dose to the breast during fully-3D imaging.
Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters
Qiu, Bo; Liang, Jian; Xie, Weihao; Deng, Xiaowu; Qi, Zhenyu
2017-01-01
Objective: To assess the breast dose during a routine thoracic cone-beam CT (CBCT) check with the efforts to explore the possible dose reduction strategy. Materials and Methods: Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were used to measure breast surface doses during a thorax kV CBCT scan in an anthropomorphic phantom. Breast doses for different scanning protocols and breast sizes were compared. Dose reduction was attempted by using partial arc CBCT scan with bowtie filter. The impact of this dose reduction strategy on image registration accuracy was investigated. Results: The average breast surface doses were 20.02 mGy and 11.65 mGy for thoracic CBCT without filtration and with filtration, respectively. This indicates a dose reduction of 41.8% by use of bowtie filter. It was found 220° partial arc scanning significantly reduced the dose to contralateral breast (44.4% lower than ipsilateral breast), while the image registration accuracy was not compromised. Conclusions: Breast dose reduction can be achieved by using ipsilateral 220° partial arc scan with bowtie filter. This strategy also provides sufficient image quality for thorax image registration in daily patient positioning verification. PMID:28423624
Boone, John M; Yang, Kai; Burkett, George W; Packard, Nathan J; Huang, Shih-ying; Bowen, Spencer; Badawi, Ramsey D; Lindfors, Karen K
2010-02-01
Mammography has served the population of women who are at-risk for breast cancer well over the past 30 years. While mammography has undergone a number of changes as digital detector technology has advanced, other modalities such as computed tomography have experienced technological sophistication over this same time frame as well. The advent of large field of view flat panel detector systems enable the development of breast CT and several other niche CT applications, which rely on cone beam geometry. The breast, it turns out, is well suited to cone beam CT imaging because the lack of bones reduces artifacts, and the natural tapering of the breast anteriorly reduces the x-ray path lengths through the breast at large cone angle, reducing cone beam artifacts as well. We are in the process of designing a third prototype system which will enable the use of breast CT for image guided interventional procedures. This system will have several copies fabricated so that several breast CT scanners can be used in a multi-institutional clinical trial to better understand the role that this technology can bring to breast imaging.
McWhirter, J E; Hoffman-Goetz, L; Clarke, J N
2012-06-01
Media are an important source of breast cancer information for women. Visual images influence recall and comprehension of information. Research on breast cancer in the media has infrequently focused on images. Using directed content analysis, we compared content, tone, and themes in images (n = 91) and articles (n = 31) in Canadian women's and fashion (n = 6) magazines (2005-2010). About half of the articles (51.6%) had both positive and negative tone; in contrast, 87.7% of women in the images had positive facial expressions. Women in the images were Caucasian (80.9%), young (81.3%), attractive (99.2%), had a healthy body type (93.8%), and appeared to have intact breasts (100%). Images of screening/treatment (5.5%) and visual impact of disease/treatment on the body (4.4%) were rare. The most common theme in the articles was medical issues (35.5%); in the images, it was beauty or fashion (15.4%). The potential impact of these divergent messages for breast cancer education is discussed.
Imaging features of carcinoid tumors metastatic to the breast.
Glazebrook, Katrina N; Jones, Katie N; Dilaveri, Christina A; Perry, Kyle; Reynolds, Carol
2011-06-29
The objective of this study was to describe the imaging findings of carcinoid tumors metastatic to the breast, with pathologic and clinical correlations. We searched our surgical database for cases of pathologically proven carcinoid tumors metastatic to the breast from October 1, 2000, to May 31, 2010. Of the approximate 10,000 breast biopsies identified, 7000 had malignant findings. Ten cases of metastatic carcinoid (0.1% of all malignancies), all with imaging studies available for review, were included in the study. All patients were women and had their primary carcinoid in the gastrointestinal tract (n=9) or lung (n = 1). One patient presented with a palpable breast mass and no history of carcinoid tumor; an ileal carcinoid was discovered after the pathologic diagnosis of metastatic carcinoid was established. In the breast, tumors presented as solitary lesions in half the cases. Metastases to the breast typically presented as circumscribed masses mammographically and as hypoechoic circumscribed masses ultrasonographically; some showed increased through-transmission and increased vascularity with color Doppler evaluation. Five patients had octreotide scans; of these, 4 had increased focal activity in the region of metastasis within the breast. Six patients underwent computed tomography. Without contrast, nodular masses were observed; with contrast, the masses showed rapid enhancement during arterial phase imaging. Magnetic resonance imaging (n = 4) also showed rapid enhancement and washout kinetics after contrast administration. Recognition of carcinoid metastases to the breast in patients with known or occult primary carcinoid tumors is important to avoid unnecessary treatment for primary breast cancer.
Izumori, Ayumi; Horii, Rie; Akiyama, Futoshi; Iwase, Takuji
2013-01-01
With the recent advances in modalities for diagnostic imaging of the breast, it is now essential to detect isoechoic masses and small nonmass lesions, to which little attention has so far been paid using ultrasound (US) of the breast. It will be possible with the observation method to understand normal breast structural images and anatomy. We elucidated the detailed histological architecture of the normal breast, information indispensable for diagnostic US of the breast. Verification of the above hypotheses was carried out using the breasts of 11 patients who underwent total mastectomy at our clinic. Isoechoic structures with fat are lobules, all ducts, and surrounding stroma that support the ducts; intervening hyperechoic areas are edematous stroma and fat-containing stroma that support the breast. By taking an isoechoic structure that reflects the course of the ducts as the basic structure for observation, the boundary between the lobes can be inferred. Detection of deviations from the normal structure using the method for interpreting three-dimensional ultrasound images of mammary lobes is a radical new approach for diagnosing breast cancer. This technique is very simple and amenable to standardization once one understands the underlying theory. Furthermore, it is useful as a screening method as well as for easy detection of faint minute lesions that can only be detected by magnetic resonance imaging or second-look targeted US.
Imaging Breast Density: Established and Emerging Modalities1
Chen, Jeon-Hor; Gulsen, Gultekin; Su, Min-Ying
2015-01-01
Mammographic density has been proven as an independent risk factor for breast cancer. Women with dense breast tissue visible on a mammogram have a much higher cancer risk than women with little density. A great research effort has been devoted to incorporate breast density into risk prediction models to better estimate each individual’s cancer risk. In recent years, the passage of breast density notification legislation in many states in USA requires that every mammography report should provide information regarding the patient’s breast density. Accurate definition and measurement of breast density are thus important, which may allow all the potential clinical applications of breast density to be implemented. Because the two-dimensional mammography-based measurement is subject to tissue overlapping and thus not able to provide volumetric information, there is an urgent need to develop reliable quantitative measurements of breast density. Various new imaging technologies are being developed. Among these new modalities, volumetric mammographic density methods and three-dimensional magnetic resonance imaging are the most well studied. Besides, emerging modalities, including different x-ray–based, optical imaging, and ultrasound-based methods, have also been investigated. All these modalities may either overcome some fundamental problems related to mammographic density or provide additional density and/or compositional information. The present review article aimed to summarize the current established and emerging imaging techniques for the measurement of breast density and the evidence of the clinical use of these density methods from the literature. PMID:26692524
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kiarashi, Nooshin; Nolte, Adam C.; Sturgeon, Gregory M.
Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated bymore » high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images were in general agreement with real human images. The Singlet approach offered more realistic contrast as compared to the Doublet approach, but at the expense of air bubbles and air pockets that formed during the filling process. Conclusions: The presented physical breast phantoms and their matching virtual breast phantoms offer realistic breast anatomy, patient variability, and ease of use, making them a potential candidate for performing both system quality control testing and virtual clinical trials.« less
A new, open-source, multi-modality digital breast phantom
NASA Astrophysics Data System (ADS)
Graff, Christian G.
2016-03-01
An anthropomorphic digital breast phantom has been developed with the goal of generating random voxelized breast models that capture the anatomic variability observed in vivo. This is a new phantom and is not based on existing digital breast phantoms or segmentation of patient images. It has been designed at the outset to be modality agnostic (i.e., suitable for use in modeling x-ray based imaging systems, magnetic resonance imaging, and potentially other imaging systems) and open source so that users may freely modify the phantom to suit a particular study. In this work we describe the modeling techniques that have been developed, the capabilities and novel features of this phantom, and study simulated images produced from it. Starting from a base quadric, a series of deformations are performed to create a breast with a particular volume and shape. Initial glandular compartments are generated using a Voronoi technique and a ductal tree structure with terminal duct lobular units is grown from the nipple into each compartment. An additional step involving the creation of fat and glandular lobules using a Perlin noise function is performed to create more realistic glandular/fat tissue interfaces and generate a Cooper's ligament network. A vascular tree is grown from the chest muscle into the breast tissue. Breast compression is performed using a neo-Hookean elasticity model. We show simulated mammographic and T1-weighted MRI images and study properties of these images.
NASA Astrophysics Data System (ADS)
Krol, Andrzej; Hemingway, Susan; Kort, Kara; de la Rosa, Gustavo; Adhikary, Ravi; Masrani, Deepa; Feiglin, David; O'Connell, Avice; Nagarajan, Mahesh; Yang, Chien-Chun; Wismüller, Axel
2014-03-01
Breast conserving therapy (BCT) of breast cancer is now widely accepted due to improved cosmetic outcome and improved patients' quality of life. One of the critical issues in performing breast-conserving surgery is trying to achieve microscopically clear surgical margins while maintaining excellent cosmesis. Unfortunately, unacceptably close or positive surgical margins occur in at least 20-25% of all patients undergoing BCT requiring repeat surgical excision days or weeks later, as permanent histopathology routinely takes days to complete. Our aim is to develop a better method for intraoperative imaging of non-palpable breast malignancies excised by wire or needle localization. Providing non-deformed three dimensional imaging of the excised breast tissue should allow more accurate assessment of tumor margins and consequently allow further excision at the time of initial surgery thus limiting the enormous financial and emotional burden of additional surgery. We have designed and constructed a device that allows preservation of the excised breast tissue in its natural anatomic position relative to the breast as it is imaged to assess adequate excision. We performed initial tests with needle-guided lumpectomy specimens using micro-CT and digital breast tomosynthesis (DBT). Our device consists of a plastic sphere inside a cylindrical holder. The surgeon inserts a freshly excised piece of breast tissue into the sphere and matches its anatomic orientation with the fiducial markers on the sphere. A custom-shaped foam is placed inside the sphere to prevent specimen deformation due to gravity. DBT followed by micro-CT images of the specimen were obtained. We confirmed that our device preserved spatial orientation of the excised breast tissue and that the location error was lower than 10mm and 10 degrees. The initial obtained results indicate that breast lesions containing microcalcifications allow a good 3D imaging of margins providing immediate intraoperative feedback for further excision as needed at the initial operation.
Vreugdenburg, Thomas D; Laurence, Caroline O; Willis, Cameron D; Mundy, Linda; Hiller, Janet E
2014-09-01
To describe the nature and frequency of information presented on direct-to-consumer websites for emerging breast cancer imaging devices. Content analysis of Australian website advertisements from 2 March 2011 to 30 March 2012, for three emerging breast cancer imaging devices: digital infrared thermal imaging, electrical impedance scanning and electronic palpation imaging. Type of imaging offered, device safety, device performance, application of device, target population, supporting evidence and comparator tests. Thirty-nine unique Australian websites promoting a direct-to-consumer breast imaging device were identified. Despite a lack of supporting evidence, 22 websites advertised devices for diagnosis, 20 advertised devices for screening, 13 advertised devices for prevention and 13 advertised devices for identifying breast cancer risk factors. Similarly, advertised ranges of diagnostic sensitivity (78%-99%) and specificity (44%-91%) were relatively high compared with published literature. Direct comparisons with conventional screening tools that favoured the new device were highly prominent (31 websites), and one-third of websites (12) explicitly promoted their device as a suitable alternative. Australian websites for emerging breast imaging devices, which are also available internationally, promote the use of such devices as safe and effective solutions for breast cancer screening and diagnosis in a range of target populations. Many of these claims are not supported by peer-reviewed evidence, raising questions about the manner in which these devices and their advertising material are regulated, particularly when they are promoted as direct alternatives to established screening interventions.
Robust linearized image reconstruction for multifrequency EIT of the breast.
Boverman, Gregory; Kao, Tzu-Jen; Kulkarni, Rujuta; Kim, Bong Seok; Isaacson, David; Saulnier, Gary J; Newell, Jonathan C
2008-10-01
Electrical impedance tomography (EIT) is a developing imaging modality that is beginning to show promise for detecting and characterizing tumors in the breast. At Rensselaer Polytechnic Institute, we have developed a combined EIT-tomosynthesis system that allows for the coregistered and simultaneous analysis of the breast using EIT and X-ray imaging. A significant challenge in EIT is the design of computationally efficient image reconstruction algorithms which are robust to various forms of model mismatch. Specifically, we have implemented a scaling procedure that is robust to the presence of a thin highly-resistive layer of skin at the boundary of the breast and we have developed an algorithm to detect and exclude from the image reconstruction electrodes that are in poor contact with the breast. In our initial clinical studies, it has been difficult to ensure that all electrodes make adequate contact with the breast, and thus procedures for the use of data sets containing poorly contacting electrodes are particularly important. We also present a novel, efficient method to compute the Jacobian matrix for our linearized image reconstruction algorithm by reducing the computation of the sensitivity for each voxel to a quadratic form. Initial clinical results are presented, showing the potential of our algorithms to detect and localize breast tumors.
Chen, Shuang-Qing; Huang, Min; Shen, Yu-Ying; Liu, Chen-Lu; Xu, Chuan-Xiao
2017-03-01
The study aimed to evaluate the usefulness of an abbreviated protocol (AP) of magnetic resonance imaging (MRI) in comparison to a full diagnostic protocol (FDP) of MRI in the breast cancer screening with dense breast tissue. There are 478 female participants with dense breast tissue and negative mammography results, who were imaged with MRI using AP and FDP. The AP and FDP images were analyzed separately, and the sensitivity and specificity of breast cancer detection were calculated. The chi-square test and receiver operating characteristics curves were used to assess the breast cancer diagnostic capabilities of the two protocols. Sixteen cases of breast cancer from 478 patients with dense breasts were detected using the FDP method, with pathologic confirmation of nine cases of ductal carcinoma in situ, six cases of invasive ductal carcinoma, and one case of mucinous carcinoma. Fifteen cases of breast cancer were successfully screened using the AP method. The sensitivity showed no obvious significant difference between AP and FDP (χ 2 = 0.592, P = 0.623), but the specificity showed a statistically significant difference (χ 2 = 4.619, P = 0.036). The receiver operating characteristics curves showed high efficacy of both methods in the detection of breast cancer in dense breast tissue (the areas under the curve were 0.931 ± 0.025 and 0.947 ± 0.024, respectively), and the ability to diagnose breast cancer was not statistically significantly different between the two methods. The AP of MRI may improve the detection rate of breast cancer in dense breast tissue, and it may be useful in efficient breast cancer screening. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Rupcich, Franco John
The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon-counting was investigated for six different energy bin combinations using a bench-top energy-resolving CT system with a cadmium zinc telluride (CZT) detector. The non-ideal spectral response reduced the CNR for the projection-based weighted images, while image-based weighting improved CNR for five out of the six investigated bin combinations, despite this non-ideal response, indicating potential for image-based weighting to reduce breast dose during dedicated breast CT.
On the Forward Scattering of Microwave Breast Imaging
Lui, Hoi-Shun; Fhager, Andreas; Persson, Mikael
2012-01-01
Microwave imaging for breast cancer detection has been of significant interest for the last two decades. Recent studies focus on solving the imaging problem using an inverse scattering approach. Efforts have mainly been focused on the development of the inverse scattering algorithms, experimental setup, antenna design and clinical trials. However, the success of microwave breast imaging also heavily relies on the quality of the forward data such that the tumor inside the breast volume is well illuminated. In this work, a numerical study of the forward scattering data is conducted. The scattering behavior of simple breast models under different polarization states and aspect angles of illumination are considered. Numerical results have demonstrated that better data contrast could be obtained when the breast volume is illuminated using cross-polarized components in linear polarization basis or the copolarized components in the circular polarization basis. PMID:22611371
Segmentation of the pectoral muscle in breast MR images using structure tensor and deformable model
NASA Astrophysics Data System (ADS)
Lee, Myungeun; Kim, Jong Hyo
2012-02-01
Recently, breast MR images have been used in wider clinical area including diagnosis, treatment planning, and treatment response evaluation, which requests quantitative analysis and breast tissue segmentation. Although several methods have been proposed for segmenting MR images, segmenting out breast tissues robustly from surrounding structures in a wide range of anatomical diversity still remains challenging. Therefore, in this paper, we propose a practical and general-purpose approach for segmenting the pectoral muscle boundary based on the structure tensor and deformable model. The segmentation work flow comprises four key steps: preprocessing, detection of the region of interest (ROI) within the breast region, segmenting the pectoral muscle and finally extracting and refining the pectoral muscle boundary. From experimental results we show that the proposed method can segment the pectoral muscle robustly in diverse patient cases. In addition, the proposed method will allow the application of the quantification research for various breast images.
High frame-rate MR-guided near-infrared tomography system to monitor breast hemodynamics
NASA Astrophysics Data System (ADS)
Li, Zhiqiu; Jiang, Shudong; Krishnaswamy, Venkataramanan; Davis, Scott C.; Srinivasan, Subhadra; Paulsen, Keith D.; Pogue, Brian W.
2011-02-01
A near-infrared (NIR) tomography system with spectral-encoded sources at two wavelength bands was built to quantify the temporal contrast at 20 Hz bandwidth, while imaging breast tissue. The NIR system was integrated with a magnetic resonance (MR) machine through a custom breast coil interface, and both NIR data and MR images were acquired simultaneously. MR images provided breast tissue structural information for NIR reconstruction. Acquisition of finger pulse oximeter (PO) plethysmogram was synchronized with the NIR system in the experiment to offer a frequency-locked reference. The recovered absorption coefficients of the breast at two wavelengths showed identical temporal frequency as the PO output, proving this multi-modality design can recover the small pulsatile variation of absorption property in breast tissue related to the heartbeat. And it also showed the system's ability on novel contrast imaging of fast flow signals in deep tissue.
Sechopoulos, Ioannis
2013-01-01
Many important post-acquisition aspects of breast tomosynthesis imaging can impact its clinical performance. Chief among them is the reconstruction algorithm that generates the representation of the three-dimensional breast volume from the acquired projections. But even after reconstruction, additional processes, such as artifact reduction algorithms, computer aided detection and diagnosis, among others, can also impact the performance of breast tomosynthesis in the clinical realm. In this two part paper, a review of breast tomosynthesis research is performed, with an emphasis on its medical physics aspects. In the companion paper, the first part of this review, the research performed relevant to the image acquisition process is examined. This second part will review the research on the post-acquisition aspects, including reconstruction, image processing, and analysis, as well as the advanced applications being investigated for breast tomosynthesis. PMID:23298127
Newman, Martin I.; Seeley, Neil; Hutchins, Jacob; Smith, Kevin L.; Mena, Gabriel; Selber, Jesse C.; Saint-Cyr, Michel H.; Gadsden, Jeffrey C.
2017-01-01
Enhanced recovery after surgery is a multidisciplinary perioperative clinical pathway that uses evidence-based interventions to improve the patient experience as well as increase satisfaction, reduce costs, mitigate the surgical stress response, accelerate functional recovery, and decrease perioperative complications. One of the most important elements of enhanced recovery pathways is multimodal pain management. Herein, aspects relating to multimodal analgesia following breast surgical procedures are discussed with the understanding that treatment decisions should be individualized and guided by sound clinical judgment. A review of liposomal bupivacaine, a prolonged-release formulation of bupivacaine, in the management of postoperative pain following breast surgical procedures is presented, and technical guidance regarding optimal administration of liposomal bupivacaine is provided. PMID:29062649
USDA-ARS?s Scientific Manuscript database
Non-destructive and rapid prediction of quality attributes of chicken breast fillets using visible and near-infrared (VNIR) hyperspectral imaging (400-1000 nm) was carried out in this work. All hyperspectral images were acquired for bone (dorsal) side of chicken breast. A forward principal component...
2016-07-01
AWARD NUMBER: W81XWH- 14-1-0192 TITLE: Next-Generation Molecular Histology Using Highly Multiplexed Ion Beam Imaging (MIBI) of Breast Cancer...DATES COVERED 4. TITLE AND SUBTITLE Next-Generation Molecular Histology Using Highly Multiplexed Ion Beam Imaging (MIBI) of Breast Cancer Tissue
2010-03-01
TITLE: INCORPORATING FUNCTIONAL IMAGING INFORMATION TO rpFNA ANALYSIS FOR BREAST CANCER DETECTION IN HIGH-RISK WOMEN PRINCIPAL INVESTIGATOR...Imaging Information into rpFNA 5a. CONTRACT NUMBER Analysis for Breast Cancer Detection in High Risk Women 5b. GRANT NUMBER W81XWH-08-1-0192 5c...results of random periareolar fine needle aspiration (rpFNA) in women at high risk for breast cancer. In this second year of work, efforts have been
Contour classification in thermographic images for detection of breast cancer
NASA Astrophysics Data System (ADS)
Okuniewski, Rafał; Nowak, Robert M.; Cichosz, Paweł; Jagodziński, Dariusz; Matysiewicz, Mateusz; Neumann, Łukasz; Oleszkiewicz, Witold
2016-09-01
Thermographic images of breast taken by the Braster device are uploaded into web application which uses different classification algorithms to automatically decide whether a patient should be more thoroughly examined. This article presents the approach to the task of classifying contours visible on thermographic images of breast taken by the Braster device in order to make the decision about the existence of cancerous tumors in breast. It presents the results of the researches conducted on the different classification algorithms.
Timmermans, Lore; Bleyen, Luc; Bacher, Klaus; Van Herck, Koen; Lemmens, Kim; Van Ongeval, Chantal; Van Steen, Andre; Martens, Patrick; De Brabander, Isabel; Goossens, Mathieu; Thierens, Hubert
2017-09-01
To investigate if direct radiography (DR) performs better than screen-film mammography (SF) and computed radiography (CR) in dense breasts in a decentralized organised Breast Cancer Screening Programme. To this end, screen-detected versus interval cancers were studied in different BI-RADS density classes for these imaging modalities. The study cohort consisted of 351,532 women who participated in the Flemish Breast Cancer Screening Programme in 2009 and 2010. Information on screen-detected and interval cancers, breast density scores of radiologist second readers, and imaging modality was obtained by linkage of the databases of the Centre of Cancer Detection and the Belgian Cancer Registry. Overall, 67% of occurring breast cancers are screen detected and 33% are interval cancers, with DR performing better than SF and CR. The interval cancer rate increases gradually with breast density, regardless of modality. In the high-density class, the interval cancer rate exceeds the cancer detection rate for SF and CR, but not for DR. DR is superior to SF and CR with respect to cancer detection rates for high-density breasts. To reduce the high interval cancer rate in dense breasts, use of an additional imaging technique in screening can be taken into consideration. • Interval cancer rate increases gradually with breast density, regardless of modality. • Cancer detection rate in high-density breasts is superior in DR. • IC rate exceeds CDR for SF and CR in high-density breasts. • DR performs better in high-density breasts for third readings and false-positives.
Pertuz, Said; McDonald, Elizabeth S.; Weinstein, Susan P.; Conant, Emily F.
2016-01-01
Purpose To assess a fully automated method for volumetric breast density (VBD) estimation in digital breast tomosynthesis (DBT) and to compare the findings with those of full-field digital mammography (FFDM) and magnetic resonance (MR) imaging. Materials and Methods Bilateral DBT images, FFDM images, and sagittal breast MR images were retrospectively collected from 68 women who underwent breast cancer screening from October 2011 to September 2012 with institutional review board–approved, HIPAA-compliant protocols. A fully automated computer algorithm was developed for quantitative estimation of VBD from DBT images. FFDM images were processed with U.S. Food and Drug Administration–cleared software, and the MR images were processed with a previously validated automated algorithm to obtain corresponding VBD estimates. Pearson correlation and analysis of variance with Tukey-Kramer post hoc correction were used to compare the multimodality VBD estimates. Results Estimates of VBD from DBT were significantly correlated with FFDM-based and MR imaging–based estimates with r = 0.83 (95% confidence interval [CI]: 0.74, 0.90) and r = 0.88 (95% CI: 0.82, 0.93), respectively (P < .001). The corresponding correlation between FFDM and MR imaging was r = 0.84 (95% CI: 0.76, 0.90). However, statistically significant differences after post hoc correction (α = 0.05) were found among VBD estimates from FFDM (mean ± standard deviation, 11.1% ± 7.0) relative to MR imaging (16.6% ± 11.2) and DBT (19.8% ± 16.2). Differences between VDB estimates from DBT and MR imaging were not significant (P = .26). Conclusion Fully automated VBD estimates from DBT, FFDM, and MR imaging are strongly correlated but show statistically significant differences. Therefore, absolute differences in VBD between FFDM, DBT, and MR imaging should be considered in breast cancer risk assessment. © RSNA, 2015 Online supplemental material is available for this article. PMID:26491909
Automated Segmentation of Nuclei in Breast Cancer Histopathology Images.
Paramanandam, Maqlin; O'Byrne, Michael; Ghosh, Bidisha; Mammen, Joy John; Manipadam, Marie Therese; Thamburaj, Robinson; Pakrashi, Vikram
2016-01-01
The process of Nuclei detection in high-grade breast cancer images is quite challenging in the case of image processing techniques due to certain heterogeneous characteristics of cancer nuclei such as enlarged and irregularly shaped nuclei, highly coarse chromatin marginalized to the nuclei periphery and visible nucleoli. Recent reviews state that existing techniques show appreciable segmentation accuracy on breast histopathology images whose nuclei are dispersed and regular in texture and shape; however, typical cancer nuclei are often clustered and have irregular texture and shape properties. This paper proposes a novel segmentation algorithm for detecting individual nuclei from Hematoxylin and Eosin (H&E) stained breast histopathology images. This detection framework estimates a nuclei saliency map using tensor voting followed by boundary extraction of the nuclei on the saliency map using a Loopy Back Propagation (LBP) algorithm on a Markov Random Field (MRF). The method was tested on both whole-slide images and frames of breast cancer histopathology images. Experimental results demonstrate high segmentation performance with efficient precision, recall and dice-coefficient rates, upon testing high-grade breast cancer images containing several thousand nuclei. In addition to the optimal performance on the highly complex images presented in this paper, this method also gave appreciable results in comparison with two recently published methods-Wienert et al. (2012) and Veta et al. (2013), which were tested using their own datasets.
Automated Segmentation of Nuclei in Breast Cancer Histopathology Images
Paramanandam, Maqlin; O’Byrne, Michael; Ghosh, Bidisha; Mammen, Joy John; Manipadam, Marie Therese; Thamburaj, Robinson; Pakrashi, Vikram
2016-01-01
The process of Nuclei detection in high-grade breast cancer images is quite challenging in the case of image processing techniques due to certain heterogeneous characteristics of cancer nuclei such as enlarged and irregularly shaped nuclei, highly coarse chromatin marginalized to the nuclei periphery and visible nucleoli. Recent reviews state that existing techniques show appreciable segmentation accuracy on breast histopathology images whose nuclei are dispersed and regular in texture and shape; however, typical cancer nuclei are often clustered and have irregular texture and shape properties. This paper proposes a novel segmentation algorithm for detecting individual nuclei from Hematoxylin and Eosin (H&E) stained breast histopathology images. This detection framework estimates a nuclei saliency map using tensor voting followed by boundary extraction of the nuclei on the saliency map using a Loopy Back Propagation (LBP) algorithm on a Markov Random Field (MRF). The method was tested on both whole-slide images and frames of breast cancer histopathology images. Experimental results demonstrate high segmentation performance with efficient precision, recall and dice-coefficient rates, upon testing high-grade breast cancer images containing several thousand nuclei. In addition to the optimal performance on the highly complex images presented in this paper, this method also gave appreciable results in comparison with two recently published methods—Wienert et al. (2012) and Veta et al. (2013), which were tested using their own datasets. PMID:27649496
Breast MRI radiomics: comparison of computer- and human-extracted imaging phenotypes.
Sutton, Elizabeth J; Huang, Erich P; Drukker, Karen; Burnside, Elizabeth S; Li, Hui; Net, Jose M; Rao, Arvind; Whitman, Gary J; Zuley, Margarita; Ganott, Marie; Bonaccio, Ermelinda; Giger, Maryellen L; Morris, Elizabeth A
2017-01-01
In this study, we sought to investigate if computer-extracted magnetic resonance imaging (MRI) phenotypes of breast cancer could replicate human-extracted size and Breast Imaging-Reporting and Data System (BI-RADS) imaging phenotypes using MRI data from The Cancer Genome Atlas (TCGA) project of the National Cancer Institute. Our retrospective interpretation study involved analysis of Health Insurance Portability and Accountability Act-compliant breast MRI data from The Cancer Imaging Archive, an open-source database from the TCGA project. This study was exempt from institutional review board approval at Memorial Sloan Kettering Cancer Center and the need for informed consent was waived. Ninety-one pre-operative breast MRIs with verified invasive breast cancers were analysed. Three fellowship-trained breast radiologists evaluated the index cancer in each case according to size and the BI-RADS lexicon for shape, margin, and enhancement (human-extracted image phenotypes [HEIP]). Human inter-observer agreement was analysed by the intra-class correlation coefficient (ICC) for size and Krippendorff's α for other measurements. Quantitative MRI radiomics of computerised three-dimensional segmentations of each cancer generated computer-extracted image phenotypes (CEIP). Spearman's rank correlation coefficients were used to compare HEIP and CEIP. Inter-observer agreement for HEIP varied, with the highest agreement seen for size (ICC 0.679) and shape (ICC 0.527). The computer-extracted maximum linear size replicated the human measurement with p < 10 -12 . CEIP of shape, specifically sphericity and irregularity, replicated HEIP with both p values < 0.001. CEIP did not demonstrate agreement with HEIP of tumour margin or internal enhancement. Quantitative radiomics of breast cancer may replicate human-extracted tumour size and BI-RADS imaging phenotypes, thus enabling precision medicine.
Characterization of human breast cancer tissues by infrared imaging.
Verdonck, M; Denayer, A; Delvaux, B; Garaud, S; De Wind, R; Desmedt, C; Sotiriou, C; Willard-Gallo, K; Goormaghtigh, E
2016-01-21
Fourier Transform InfraRed (FTIR) spectroscopy coupled to microscopy (IR imaging) has shown unique advantages in detecting morphological and molecular pathologic alterations in biological tissues. The aim of this study was to evaluate the potential of IR imaging as a diagnostic tool to identify characteristics of breast epithelial cells and the stroma. In this study a total of 19 breast tissue samples were obtained from 13 patients. For 6 of the patients, we also obtained Non-Adjacent Non-Tumor tissue samples. Infrared images were recorded on the main cell/tissue types identified in all breast tissue samples. Unsupervised Principal Component Analyses and supervised Partial Least Square Discriminant Analyses (PLS-DA) were used to discriminate spectra. Leave-one-out cross-validation was used to evaluate the performance of PLS-DA models. Our results show that IR imaging coupled with PLS-DA can efficiently identify the main cell types present in FFPE breast tissue sections, i.e. epithelial cells, lymphocytes, connective tissue, vascular tissue and erythrocytes. A second PLS-DA model could distinguish normal and tumor breast epithelial cells in the breast tissue sections. A patient-specific model reached particularly high sensitivity, specificity and MCC rates. Finally, we showed that the stroma located close or at distance from the tumor exhibits distinct spectral characteristics. In conclusion FTIR imaging combined with computational algorithms could be an accurate, rapid and objective tool to identify/quantify breast epithelial cells and differentiate tumor from normal breast tissue as well as normal from tumor-associated stroma, paving the way to the establishment of a potential complementary tool to ensure safe tumor margins.
The role of oxidized regenerate cellulose to prevent cosmetic defects in oncoplastic breast surgery.
Franceschini, G; Visconti, G; Terribile, D; Fabbri, C; Magno, S; Di Leone, A; Salgarello, M; Masetti, R
2012-07-01
Breast conserving surgery (BCS) combined with postoperative radiotherapy has become the gold standard of locoregional treatment for the majority of patients with early-stage breast cancer, offering equivalent survival and improved body image and lifestyle scores as compared to mastectomy. In an attempt to optimize the oncologic safety and cosmetic results of BCS, oncoplastic procedures (OPP) have been introduced in recent years combining the best principles of surgical oncology with those of plastic surgery. However, even with the use of OPP, cosmetic outcomes may result unsatisfying when a large volume of parenchyma has to be removed, particularly in small-medium size breasts. The aim of this article is to report our preliminary results with the use of oxidized regenerate cellulose (ORC) (Tabotamp fibrillar, Johnson & Johnson; Ethicon, USA) as an agent to prevent cosmetic defects in patients undergoing OPP for breast cancer and to analyze the technical refinements that can enhance its efficacy in optimizing cosmetic defects. Different OPP are selected based on the location and size of the tumor as well as volume and shape of the breast. After excision of the tumor, glandular flaps are created by dissection of the residual parenchyma from the pectoralis and serratus muscles and from the skin. After careful haemostasis, five layers of ORC are positioned on the pectoralis major in the residual cavity and covered by advancement of the glandular flaps. Two additional layers of ORC are positioned above the flaps and covered by cutaneous-subcutaenous flaps. The use of ORC after OPP has shown promising preliminary results, indicating a good tolerability and positive effects on cosmesis. This simple and reliable surgical technique may allow not only to reduce the rate of post-operative bleeding and infection at the surgical site but also to improve cosmetic results.
NASA Astrophysics Data System (ADS)
Ye, Jian; Liu, Guanghui; Liu, Peng; Zhang, Shiwu; Shao, Pengfei; Smith, Zachary J.; Liu, Chenhai; Xu, Ronald X.
2018-02-01
We propose a portable fluorescence microscopic imaging system (PFMS) for intraoperative display of biliary structure and prevention of iatrogenic injuries during cholecystectomy. The system consists of a light source module, a camera module, and a Raspberry Pi computer with an LCD. Indocyanine green (ICG) is used as a fluorescent contrast agent for experimental validation of the system. Fluorescence intensities of the ICG aqueous solution at different concentration levels are acquired by our PFMS and compared with those of a commercial Xenogen IVIS system. We study the fluorescence detection depth by superposing different thicknesses of chicken breast on an ICG-loaded agar phantom. We verify the technical feasibility for identifying potential iatrogenic injury in cholecystectomy using a rat model in vivo. The proposed PFMS system is portable, inexpensive, and suitable for deployment in resource-limited settings.
The Future of Mammography: Radiology Residents’ Experiences, Attitudes, and Opinions
Baxi, Shrujal S.; Snow, Jacqueline G.; Liberman, Laura; Elkin, Elena B.
2011-01-01
OBJECTIVE The objective of our study was to assess the experiences and preferences of radiology residents with respect to breast imaging. MATERIALS AND METHODS We surveyed radiology residents at 26 programs in New York and New Jersey. Survey topics included plans for subspecialty training, beliefs, and attitudes toward breast imaging and breast cancer screening and the likelihood of interpreting mammography in the future. RESULTS Three hundred forty-four residents completed the survey (response rate, 62%). The length of time spent training in breast imaging varied from no dedicated time (37%) to 1–8 weeks (40%) to more than 9 weeks (23%). Most respondents (97%) agreed that mammography is important to women’s health. More than 85% of residents believed that mammography should be interpreted by breast imaging specialists. Respondents shared negative views about mammography, agreeing with statements that the field was associated with a high risk of malpractice (99%), stress (94%), and low reimbursement (68%). Respondents endorsed several positive attributes of mammography, including job availability (97%), flexible work schedules (94%), and few calls or emergencies (93%). Most radiology residents (93%) said that they were likely to pursue subspecialty training, and 7% expressed interest in breast imaging fellowships. CONCLUSION Radiology residents’ negative and positive views about mammography seem to be independent of time spent training in mammography and of future plans to pursue fellowship training in breast imaging. Systematic assessment of the plans and preferences of radiology residents can facilitate the development of strategies to attract trainees to careers in breast imaging. PMID:20489113
Novel Multistatic Adaptive Microwave Imaging Methods for Early Breast Cancer Detection
NASA Astrophysics Data System (ADS)
Xie, Yao; Guo, Bin; Li, Jian; Stoica, Petre
2006-12-01
Multistatic adaptive microwave imaging (MAMI) methods are presented and compared for early breast cancer detection. Due to the significant contrast between the dielectric properties of normal and malignant breast tissues, developing microwave imaging techniques for early breast cancer detection has attracted much interest lately. MAMI is one of the microwave imaging modalities and employs multiple antennas that take turns to transmit ultra-wideband (UWB) pulses while all antennas are used to receive the reflected signals. MAMI can be considered as a special case of the multi-input multi-output (MIMO) radar with the multiple transmitted waveforms being either UWB pulses or zeros. Since the UWB pulses transmitted by different antennas are displaced in time, the multiple transmitted waveforms are orthogonal to each other. The challenge to microwave imaging is to improve resolution and suppress strong interferences caused by the breast skin, nipple, and so forth. The MAMI methods we investigate herein utilize the data-adaptive robust Capon beamformer (RCB) to achieve high resolution and interference suppression. We will demonstrate the effectiveness of our proposed methods for breast cancer detection via numerical examples with data simulated using the finite-difference time-domain method based on a 3D realistic breast model.
Augmented reality for breast imaging.
Rancati, Alberto; Angrigiani, Claudio; Nava, Maurizio B; Catanuto, Giuseppe; Rocco, Nicola; Ventrice, Fernando; Dorr, Julio
2018-06-01
Augmented reality (AR) enables the superimposition of virtual reality reconstructions onto clinical images of a real patient, in real time. This allows visualization of internal structures through overlying tissues, thereby providing a virtual transparency vision of surgical anatomy. AR has been applied to neurosurgery, which utilizes a relatively fixed space, frames, and bony references; the application of AR facilitates the relationship between virtual and real data. Augmented breast imaging (ABI) is described. Breast MRI studies for breast implant patients with seroma were performed using a Siemens 3T system with a body coil and a four-channel bilateral phased-array breast coil as the transmitter and receiver, respectively. Gadolinium was injected as a contrast agent (0.1 mmol/kg at 2 mL/s) using a programmable power injector. Dicom formatted images data from 10 MRI cases of breast implant seroma and 10 MRI cases with T1-2 N0 M0 breast cancer, were imported and transformed into augmented reality images. ABI demonstrated stereoscopic depth perception, focal point convergence, 3D cursor use, and joystick fly-through. ABI can improve clinical outcomes, providing an enhanced view of the structures to work on. It should be further studied to determine its utility in clinical practice.
TU-A-17A-02: In Memoriam of Ben Galkin: Virtual Tools for Validation of X-Ray Breast Imaging Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Myers, K; Bakic, P; Abbey, C
2014-06-15
This symposium will explore simulation methods for the preclinical evaluation of novel 3D and 4D x-ray breast imaging systems – the subject of AAPM taskgroup TG234. Given the complex design of modern imaging systems, simulations offer significant advantages over long and costly clinical studies in terms of reproducibility, reduced radiation exposures, a known reference standard, and the capability for studying patient and disease subpopulations through appropriate choice of simulation parameters. Our focus will be on testing the realism of software anthropomorphic phantoms and virtual clinical trials tools developed for the optimization and validation of breast imaging systems. The symposium willmore » review the stateof- the-science, as well as the advantages and limitations of various approaches to testing realism of phantoms and simulated breast images. Approaches based upon the visual assessment of synthetic breast images by expert observers will be contrasted with approaches based upon comparing statistical properties between synthetic and clinical images. The role of observer models in the assessment of realism will be considered. Finally, an industry perspective will be presented, summarizing the role and importance of virtual tools and simulation methods in product development. The challenges and conditions that must be satisfied in order for computational modeling and simulation to play a significantly increased role in the design and evaluation of novel breast imaging systems will be addressed. Learning Objectives: Review the state-of-the science in testing realism of software anthropomorphic phantoms and virtual clinical trials tools; Compare approaches based upon the visual assessment by expert observers vs. the analysis of statistical properties of synthetic images; Discuss the role of observer models in the assessment of realism; Summarize the industry perspective to virtual methods for breast imaging.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Morris, R; Lakshmanan, M; Fong, G
Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scanmore » protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.« less
SU-E-J-22: A Feasibility Study On KV-Based Whole Breast Radiation Patient Setup
DOE Office of Scientific and Technical Information (OSTI.GOV)
Huang, Q; Zhang, M; Yue, N
Purpose: In room kilovoltage x-ray (kV) imaging provides higher contrast than Megavoltage (MV) imaging with faster acquisition time compared with on-board cone-beam computed tomography (CBCT), thus improving patient setup accuracy and efficiency. In this study we evaluated the clinical feasibility of utilizing kV imaging for whole breast radiation patient setup. Methods: For six breast cancer patients with whole breast treatment plans using two opposed tangential fields, MV-based patient setup was conducted by aligning patient markers with in room lasers and MV portal images. Beam-eye viewed kV images were acquired using Varian OBI system after the set up process. In housemore » software was developed to transfer MLC blocks information overlaying onto kV images to demonstrate the field shape for verification. KV-based patient digital shift was derived by performing rigid registration between kV image and the digitally reconstructed radiography (DRR) to align the bony structure. This digital shift between kV-based and MV-based setup was defined as setup deviation. Results: Six sets of kV images were acquired for breast patients. The mean setup deviation was 2.3mm, 2.2mm and 1.8mm for anterior-posterior, superior-inferior and left-right direction respectively. The average setup deviation magnitude was 4.3±1.7mm for six patients. Patient with large breast had a larger setup deviation (4.4–6.2mm). There was no strong correlation between MV-based shift and setup deviation. Conclusion: A preliminary clinical workflow for kV-based whole breast radiation setup was established and tested. We observed setup deviation of the magnitude below than 5mm. With the benefit of providing higher contrast and MLC block overlaid on the images for treatment field verification, it is feasible to use kV imaging for breast patient setup.« less
Sinusoidal hemangioma of the breast: diagnostic evaluation management and literature review
2017-01-01
Vascular tumors of the breast are rare and may pose a diagnostic challenge. Breast hemangioma is a very rare benign vascular neoplasm accounting for 0.4% of all breast tumors. It is most commonly detected as an incidental microscopic finding in biopsy specimens obtained for unrelated reasons. We describe here a very rare case of a sinusoidal breast hemangioma in a postmenopausal patient who presented with a palpable breast mass. A complete surgical resection was performed because the tumor exhibited atypical imaging features. We conclude that although in carefully selected cases of breast hemangioma a conservative management with follow up imaging is a reasonable option, in cases with atypical imaging or pathological characteristics a complete surgical resection of the vascular tumor is mandatory in order to exclude the possibility of an underlying angiosarcoma. PMID:28210560
Sinusoidal hemangioma of the breast: diagnostic evaluation management and literature review.
Salemis, Nikolaos S
2017-02-01
Vascular tumors of the breast are rare and may pose a diagnostic challenge. Breast hemangioma is a very rare benign vascular neoplasm accounting for 0.4% of all breast tumors. It is most commonly detected as an incidental microscopic finding in biopsy specimens obtained for unrelated reasons. We describe here a very rare case of a sinusoidal breast hemangioma in a postmenopausal patient who presented with a palpable breast mass. A complete surgical resection was performed because the tumor exhibited atypical imaging features. We conclude that although in carefully selected cases of breast hemangioma a conservative management with follow up imaging is a reasonable option, in cases with atypical imaging or pathological characteristics a complete surgical resection of the vascular tumor is mandatory in order to exclude the possibility of an underlying angiosarcoma.
Mammography; Breast cancer - mammography; Breast cancer - screening mammography; Breast lump - mammogram; Breast tomosynthesis ... images. This does not always mean you have breast cancer. Your health care provider may simply need to ...
2018-05-30
Healthy Subject; Stage 0 Breast Cancer; Stage IA Breast Cancer; Stage IB Breast Cancer; Stage IIA Breast Cancer; Stage IIB Breast Cancer; Stage IIIA Breast Cancer; Stage IIIB Breast Cancer; Stage IIIC Breast Cancer
NASA Astrophysics Data System (ADS)
Sak, Mark; Duric, Neb; Littrup, Peter; Sherman, Mark; Gierach, Gretchen
2017-03-01
Ultrasound tomography (UST) is an emerging modality that can offer quantitative measurements of breast density. Recent breakthroughs in UST image reconstruction involve the use of a waveform reconstruction as opposed to a raybased reconstruction. The sound speed (SS) images that are created using the waveform reconstruction have a much higher image quality. These waveform images offer improved resolution and contrasts between regions of dense and fatty tissues. As part of a study that was designed to assess breast density changes using UST sound speed imaging among women undergoing tamoxifen therapy, UST waveform sound speed images were then reconstructed for a subset of participants. These initial results show that changes to the parenchymal tissue can more clearly be visualized when using the waveform sound speed images. Additional quantitative testing of the waveform images was also started to test the hypothesis that waveform sound speed images are a more robust measure of breast density than ray-based reconstructions. Further analysis is still needed to better understand how tamoxifen affects breast tissue.
NASA Astrophysics Data System (ADS)
Keller, Brad M.; Nathan, Diane L.; Conant, Emily F.; Kontos, Despina
2012-03-01
Breast percent density (PD%), as measured mammographically, is one of the strongest known risk factors for breast cancer. While the majority of studies to date have focused on PD% assessment from digitized film mammograms, digital mammography (DM) is becoming increasingly common, and allows for direct PD% assessment at the time of imaging. This work investigates the accuracy of a generalized linear model-based (GLM) estimation of PD% from raw and postprocessed digital mammograms, utilizing image acquisition physics, patient characteristics and gray-level intensity features of the specific image. The model is trained in a leave-one-woman-out fashion on a series of 81 cases for which bilateral, mediolateral-oblique DM images were available in both raw and post-processed format. Baseline continuous and categorical density estimates were provided by a trained breast-imaging radiologist. Regression analysis is performed and Pearson's correlation, r, and Cohen's kappa, κ, are computed. The GLM PD% estimation model performed well on both processed (r=0.89, p<0.001) and raw (r=0.75, p<0.001) images. Model agreement with radiologist assigned density categories was also high for processed (κ=0.79, p<0.001) and raw (κ=0.76, p<0.001) images. Model-based prediction of breast PD% could allow for a reproducible estimation of breast density, providing a rapid risk assessment tool for clinical practice.
Early Breast Cancer Diagnosis Using Microwave Imaging via Space-Frequency Algorithm
NASA Astrophysics Data System (ADS)
Vemulapalli, Spandana
The conventional breast cancer detection methods have limitations ranging from ionizing radiations, low specificity to high cost. These limitations make way for a suitable alternative called Microwave Imaging, as a screening technique in the detection of breast cancer. The discernible differences between the benign, malignant and healthy breast tissues and the ability to overcome the harmful effects of ionizing radiations make microwave imaging, a feasible breast cancer detection technique. Earlier studies have shown the variation of electrical properties of healthy and malignant tissues as a function of frequency and hence stimulates high bandwidth requirement. A Ultrawideband, Wideband and Narrowband arrays have been designed, simulated and optimized for high (44%), medium (33%) and low (7%) bandwidths respectively, using the EM (electromagnetic software) called FEKO. These arrays are then used to illuminate the breast model (phantom) and the received backscattered signals are obtained in the near field for each case. The Microwave Imaging via Space-Time (MIST) beamforming algorithm in the frequency domain, is next applied to these near field backscattered monostatic frequency response signals for the image reconstruction of the breast model. The main purpose of this investigation is to access the impact of bandwidth and implement a novel imaging technique for use in the early detection of breast cancer. Earlier studies show the implementation of the MIST imaging algorithm on the time domain signals via a frequency domain beamformer. The performance evaluation of the imaging algorithm on the frequency response signals has been carried out in the frequency domain. The energy profile of the breast in the spatial domain is created via the frequency domain Parseval's theorem. The beamformer weights calculated using these the MIST algorithm (not including the effect of the skin) has been calculated for Ultrawideband, Wideband and Narrowband arrays, respectively. Quality metrics such as dynamic range, radiometric resolution etc. are also evaluated for all the three types of arrays.
Diagnosis of breast cancer by tissue analysis
Bhattacharyya, Debnath; Bandyopadhyay, Samir Kumar
2013-01-01
In this paper, we propose a technique to locate abnormal growth of cells in breast tissue and suggest further pathological test, when require. We compare normal breast tissue with malignant invasive breast tissue by a series of image processing steps. Normal ductal epithelial cells and ductal/lobular invasive carcinogenic cells also consider for comparison here in this paper. In fact, features of cancerous breast tissue (invasive) are extracted and analyses with normal breast tissue. We also suggest the breast cancer recognition technique through image processing and prevention by controlling p53 gene mutation to some extent. PMID:23372340
Robertson, Stephanie; Azizpour, Hossein; Smith, Kevin; Hartman, Johan
2018-04-01
Breast cancer is the most common malignant disease in women worldwide. In recent decades, earlier diagnosis and better adjuvant therapy have substantially improved patient outcome. Diagnosis by histopathology has proven to be instrumental to guide breast cancer treatment, but new challenges have emerged as our increasing understanding of cancer over the years has revealed its complex nature. As patient demand for personalized breast cancer therapy grows, we face an urgent need for more precise biomarker assessment and more accurate histopathologic breast cancer diagnosis to make better therapy decisions. The digitization of pathology data has opened the door to faster, more reproducible, and more precise diagnoses through computerized image analysis. Software to assist diagnostic breast pathology through image processing techniques have been around for years. But recent breakthroughs in artificial intelligence (AI) promise to fundamentally change the way we detect and treat breast cancer in the near future. Machine learning, a subfield of AI that applies statistical methods to learn from data, has seen an explosion of interest in recent years because of its ability to recognize patterns in data with less need for human instruction. One technique in particular, known as deep learning, has produced groundbreaking results in many important problems including image classification and speech recognition. In this review, we will cover the use of AI and deep learning in diagnostic breast pathology, and other recent developments in digital image analysis. Copyright © 2017 Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Carton, Ann-Katherine; Ullberg, Christer; Lindman, Karin
2010-11-15
Purpose: Dual-energy (DE) iodine contrast-enhanced x-ray imaging of the breast has been shown to identify cancers that would otherwise be mammographically occult. In this article, theoretical modeling was performed to obtain optimally enhanced iodine images for a photon-counting digital breast tomosynthesis (DBT) system using a DE acquisition technique. Methods: In the system examined, the breast is scanned with a multislit prepatient collimator aligned with a multidetector camera. Each detector collects a projection image at a unique angle during the scan. Low-energy (LE) and high-energy (HE) projection images are acquired simultaneously in a single scan by covering alternate collimator slits withmore » Sn and Cu filters, respectively. Sn filters ranging from 0.08 to 0.22 mm thickness and Cu filters from 0.11 to 0.27 mm thickness were investigated. A tube voltage of 49 kV was selected. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. Iodine-enhanced DBT images were acquired by performing a weighted logarithmic subtraction of the HE and LE DBT images. The DE technique was evaluated for 20-80 mm thick breasts. Weighting factors, w{sub t}, that optimally cancel breast tissue were computed. Signal-difference-to-noise ratios (SDNRs) between iodine-enhanced and nonenhanced breast tissue normalized to the square root of the mean glandular dose (MGD) were computed as a function of the fraction of the MGD allocated to the HE images. Peak SDNR/{radical}(MGD) and optimal dose allocations were identified. SDNR/{radical}(MGD) and dose allocations were computed for several practical feasible system configurations (i.e., determined by the number of collimator slits covered by Sn and Cu). A practical system configuration and Sn-Cu filter pair that accounts for the trade-off between SDNR, tube-output, and MGD were selected. Results: w{sub t} depends on the Sn-Cu filter combination used, as well as on the breast thickness; to optimally cancel 0% with 50% glandular breast tissue, w{sub t} values were found to range from 0.46 to 0.72 for all breast thicknesses and Sn-Cu filter pairs studied. The optimal w{sub t} values needed to cancel all possible breast tissue glandularites vary by less than 1% for 20 mm thick breasts and 18% for 80 mm breasts. The system configuration where one collimator slit covered by Sn is alternated with two collimator slits covered by Cu delivers SDNR/{radical}(MGD) nearest to the peak value. A reasonable compromise is a 0.16 mm Sn-0.23 mm Cu filter pair, resulting in SDNR values between 1.64 and 0.61 and MGD between 0.70 and 0.53 mGy for 20-80 mm thick breasts at the maximum tube current. Conclusions: A DE acquisition technique for a photon-counting DBT imaging system has been developed and optimized.« less
Raghunath, Vignesh; Braxton, Melissa O.; Gagnon, Stephanie A.; Brunyé, Tad T.; Allison, Kimberly H.; Reisch, Lisa M.; Weaver, Donald L.; Elmore, Joann G.; Shapiro, Linda G.
2012-01-01
Context: Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists’ viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists’ viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists’ viewing strategies and time expenditures in their interpretive workflow. Aims: To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists’ attention and viewing behavior. Settings and Design: Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Materials and Methods: Participants’ foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Statistical Analysis Used: Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists’ accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Results: Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Conclusions: Data detailing mouse cursor movements may be a useful addition to future studies of pathologists’ accuracy and efficiency when using digital pathology. PMID:23372984
Raghunath, Vignesh; Braxton, Melissa O; Gagnon, Stephanie A; Brunyé, Tad T; Allison, Kimberly H; Reisch, Lisa M; Weaver, Donald L; Elmore, Joann G; Shapiro, Linda G
2012-01-01
Digital pathology has the potential to dramatically alter the way pathologists work, yet little is known about pathologists' viewing behavior while interpreting digital whole slide images. While tracking pathologist eye movements when viewing digital slides may be the most direct method of capturing pathologists' viewing strategies, this technique is cumbersome and technically challenging to use in remote settings. Tracking pathologist mouse cursor movements may serve as a practical method of studying digital slide interpretation, and mouse cursor data may illuminate pathologists' viewing strategies and time expenditures in their interpretive workflow. To evaluate the utility of mouse cursor movement data, in addition to eye-tracking data, in studying pathologists' attention and viewing behavior. Pathologists (N = 7) viewed 10 digital whole slide images of breast tissue that were selected using a random stratified sampling technique to include a range of breast pathology diagnoses (benign/atypia, carcinoma in situ, and invasive breast cancer). A panel of three expert breast pathologists established a consensus diagnosis for each case using a modified Delphi approach. Participants' foveal vision was tracked using SensoMotoric Instruments RED 60 Hz eye-tracking system. Mouse cursor movement was tracked using a custom MATLAB script. Data on eye-gaze and mouse cursor position were gathered at fixed intervals and analyzed using distance comparisons and regression analyses by slide diagnosis and pathologist expertise. Pathologists' accuracy (defined as percent agreement with the expert consensus diagnoses) and efficiency (accuracy and speed) were also analyzed. Mean viewing time per slide was 75.2 seconds (SD = 38.42). Accuracy (percent agreement with expert consensus) by diagnosis type was: 83% (benign/atypia); 48% (carcinoma in situ); and 93% (invasive). Spatial coupling was close between eye-gaze and mouse cursor positions (highest frequency ∆x was 4.00px (SD = 16.10), and ∆y was 37.50px (SD = 28.08)). Mouse cursor position moderately predicted eye gaze patterns (Rx = 0.33 and Ry = 0.21). Data detailing mouse cursor movements may be a useful addition to future studies of pathologists' accuracy and efficiency when using digital pathology.
Breast Imaging: A Paradigm for Accountable Care Organizations.
Parikh, Jay R; Yang, Wei T
2016-02-01
Accountable care organizations (ACOs) are being promoted by the Centers of Medicare Services as alternative payment models for radiology reimbursement. Because of its clinical orientation, focus on prevention, standardized reporting, quality orientation through mandatory accreditation, and value demonstration through established outcome metrics, breast imaging offers a unique paradigm for the ACO model in radiology. In radiology, breast imaging represents the paradigm for ACOs.
Grid-Enabled Quantitative Analysis of Breast Cancer
2009-10-01
large-scale, multi-modality computerized image analysis . The central hypothesis of this research is that large-scale image analysis for breast cancer...pilot study to utilize large scale parallel Grid computing to harness the nationwide cluster infrastructure for optimization of medical image ... analysis parameters. Additionally, we investigated the use of cutting edge dataanalysis/ mining techniques as applied to Ultrasound, FFDM, and DCE-MRI Breast
Molecular Imaging and Precision Medicine in Breast Cancer.
Chudgar, Amy V; Mankoff, David A
2017-01-01
Precision medicine, basing treatment approaches on patient traits and specific molecular features of disease processes, has an important role in the management of patients with breast cancer as targeted therapies continue to improve. PET imaging offers noninvasive information that is complementary to traditional tissue biomarkers, including information about tumor burden, tumor metabolism, receptor status, and proliferation. Several PET agents that image breast cancer receptors can visually demonstrate the extent and heterogeneity of receptor-positive disease and help predict which tumors are likely to respond to targeted treatments. This review presents applications of PET imaging in the targeted treatment of breast cancer. Copyright © 2016 Elsevier Inc. All rights reserved.
Recent Advances in Microwave Imaging for Breast Cancer Detection
Kwon, Sollip
2016-01-01
Breast cancer is a disease that occurs most often in female cancer patients. Early detection can significantly reduce the mortality rate. Microwave breast imaging, which is noninvasive and harmless to human, offers a promising alternative method to mammography. This paper presents a review of recent advances in microwave imaging for breast cancer detection. We conclude by introducing new research on a microwave imaging system with time-domain measurement that achieves short measurement time and low system cost. In the time-domain measurement system, scan time would take less than 1 sec, and it does not require very expensive equipment such as VNA. PMID:28096808
The evolving role of new imaging methods in breast screening.
Houssami, Nehmat; Ciatto, Stefano
2011-09-01
The potential to avert breast cancer deaths through screening means that efforts continue to identify methods which may enhance early detection. While the role of most new imaging technologies remains in adjunct screening or in the work-up of mammography-detected abnormalities, some of the new breast imaging tests (such as MRI) have roles in screening groups of women defined by increased cancer risk. This paper highlights the evidence and the current role of new breast imaging technologies in screening, focusing on those that have broader application in population screening, including digital mammography, breast ultrasound in women with dense breasts, and computer-aided detection. It highlights that evidence on new imaging in screening comes mostly from non-randomised studies that have quantified test detection capability as adjunct to mammography, or have compared measures of screening performance for new technologies with that of conventional mammography. Two RCTs have provided high-quality evidence on the equivalence of digital and conventional mammography and on outcomes of screen-reading complemented by CAD. Many of these imaging technologies enhance cancer detection but also increase recall and false positives in screening. Copyright © 2011 Elsevier Inc. All rights reserved.
Yoshitake, Tadayuki; Giacomelli, Michael G; Cahill, Lucas C; Schmolze, Daniel B; Vardeh, Hilde; Faulkner-Jones, Beverly E; Connolly, James L; Fujimoto, James G
2016-12-01
Rapid histopathological examination of surgical specimen margins using fluorescence microscopy during breast conservation therapy has the potential to reduce the rate of positive margins on postoperative histopathology and the need for repeat surgeries. To assess the suitability of imaging modalities, we perform a direct comparison between confocal fluorescence microscopy and multiphoton microscopy for imaging unfixed tissue and compare to paraffin-embedded histology. An imaging protocol including dual channel detection of two contrast agents to implement virtual hematoxylin and eosin images is introduced that provides high quality imaging under both one and two photon excitation. Corresponding images of unfixed human breast tissue show that both confocal and multiphoton microscopy can reproduce the appearance of conventional histology without the need for physical sectioning. We further compare normal breast tissue and invasive cancer specimens imaged at multiple magnifications, and assess the effects of photobleaching for both modalities using the staining protocol. The results demonstrate that confocal fluorescence microscopy is a promising and cost-effective alternative to multiphoton microscopy for rapid histopathological evaluation of ex vivo breast tissue.
Yoshitake, Tadayuki; Giacomelli, Michael G.; Cahill, Lucas C.; Schmolze, Daniel B.; Vardeh, Hilde; Faulkner-Jones, Beverly E.; Connolly, James L.; Fujimoto, James G.
2016-01-01
Abstract. Rapid histopathological examination of surgical specimen margins using fluorescence microscopy during breast conservation therapy has the potential to reduce the rate of positive margins on postoperative histopathology and the need for repeat surgeries. To assess the suitability of imaging modalities, we perform a direct comparison between confocal fluorescence microscopy and multiphoton microscopy for imaging unfixed tissue and compare to paraffin-embedded histology. An imaging protocol including dual channel detection of two contrast agents to implement virtual hematoxylin and eosin images is introduced that provides high quality imaging under both one and two photon excitation. Corresponding images of unfixed human breast tissue show that both confocal and multiphoton microscopy can reproduce the appearance of conventional histology without the need for physical sectioning. We further compare normal breast tissue and invasive cancer specimens imaged at multiple magnifications, and assess the effects of photobleaching for both modalities using the staining protocol. The results demonstrate that confocal fluorescence microscopy is a promising and cost-effective alternative to multiphoton microscopy for rapid histopathological evaluation of ex vivo breast tissue. PMID:28032121
NASA Astrophysics Data System (ADS)
Yoshitake, Tadayuki; Giacomelli, Michael G.; Cahill, Lucas C.; Schmolze, Daniel B.; Vardeh, Hilde; Faulkner-Jones, Beverly E.; Connolly, James L.; Fujimoto, James G.
2016-12-01
Rapid histopathological examination of surgical specimen margins using fluorescence microscopy during breast conservation therapy has the potential to reduce the rate of positive margins on postoperative histopathology and the need for repeat surgeries. To assess the suitability of imaging modalities, we perform a direct comparison between confocal fluorescence microscopy and multiphoton microscopy for imaging unfixed tissue and compare to paraffin-embedded histology. An imaging protocol including dual channel detection of two contrast agents to implement virtual hematoxylin and eosin images is introduced that provides high quality imaging under both one and two photon excitation. Corresponding images of unfixed human breast tissue show that both confocal and multiphoton microscopy can reproduce the appearance of conventional histology without the need for physical sectioning. We further compare normal breast tissue and invasive cancer specimens imaged at multiple magnifications, and assess the effects of photobleaching for both modalities using the staining protocol. The results demonstrate that confocal fluorescence microscopy is a promising and cost-effective alternative to multiphoton microscopy for rapid histopathological evaluation of ex vivo breast tissue.
Positional calibration of an ultrasound image-guided robotic breast biopsy system.
Nelson, Thomas R; Tran, Amy; Fakourfar, Hourieh; Nebeker, Jakob
2012-03-01
Precision biopsy of small lesions is essential in providing high-quality patient diagnosis and management. Localization depends on high-quality imaging. We have developed a dedicated, fully automatic volume breast ultrasound (US) imaging system for early breast cancer detection. This work focuses on development of an image-guided robotic biopsy system that is integrated with the volume breast US system for performing minimally invasive breast biopsies. The objective of this work was to assess the positional accuracy of the robotic system for breast biopsy. We have adapted a compact robotic arm for performing breast biopsy. The arm incorporates a force torque sensor and is modified to accommodate breast biopsy sampling needles mounted on the robot end effector. Volume breast US images are used as input to a targeting algorithm that provides the physician with control of biopsy device guidance and trajectory optimization. In this work, the positional accuracy was evaluated using (1) a light-emitting diode (LED) mounted on the end effector and (2) a LED mounted on the end of a biopsy needle, each of which was imaged for each robot controller position as part of mapping the positional accuracy throughout a volume that would contain the breast. We measured the error in each location and the cumulative error. Robotic device performance over the volume provided mean accuracy ± SD of 0.76 ± 0.13 mm (end effector) and 0.55 ± 0.13 mm (needle sample location), sufficient for a targeting accuracy within ±1 mm, which is suitable for clinical use. Depth positioning error also was small: 0.38 ± 0.03 mm. Reproducibility was excellent with less than 0.5% variation. Overall accuracy and reproducibility of the compact robotic device were excellent, well within clinical biopsy performance requirements. Volume breast US data provide high-quality input to a biopsy sampling algorithm under physician control. Robotic devices may provide more precise device placement, assisting physicians with biopsy procedures.
Vlahiotis, Anna; Griffin, Brian; Stavros, A Thomas; Margolis, Jay
2018-01-01
Little data exist on real-world patterns and associated costs of downstream breast diagnostic procedures following an abnormal screening mammography or clinical exam. To analyze the utilization patterns in real-world clinical settings for breast imaging and diagnostic procedures, including the frequency and volume of patients and procedures, procedure sequencing, and associated health care expenditures. Using medical claims from 2011 to 2015 MarketScan Commercial and Medicare Databases, adult females with breast imaging/diagnostic procedures (diagnostic mammography, ultrasound, molecular breast imaging, tomosynthesis, magnetic resonance imaging, or biopsy) other than screening mammography were selected. Continuous health plan coverage without breast diagnostic procedures was required for ≥13 months before the first found breast diagnostic procedure (index event), with a 13-month post-index follow-up period. Key outcomes included diagnostic procedure volumes, sequences, and payments. Results reported descriptively were projected to provide US national patient and procedure volumes. The final sample of 875,526 patients was nationally projected to 12,394,432 patients annually receiving 8,732,909 diagnostic mammograms (53.3% of patients), 6,987,399 breast ultrasounds (42.4% of patients), and 1,585,856 biopsies (10.3% of patients). Following initial diagnostic procedures, 49.4% had second procedures, 20.1% followed with third procedures, and 10.0% had a fourth procedure. Mean (SD) costs for diagnostic mammograms of US$349 ($493), ultrasounds US$132 ($134), and biopsies US$1,938 ($2,343) contributed US$3.05 billion, US$0.92 billion, and US$3.07 billion, respectively, to annual diagnostic breast expenditures estimated at US$7.91 billion. The volume and expense of additional breast diagnostic testing, estimated at US$7.91 billion annually, underscores the need for technological improvements in the breast diagnostic landscape.
Three-dimensional holographic display of ultrasound computed tomograms
NASA Astrophysics Data System (ADS)
Andre, Michael P.; Janee, Helmar S.; Ysrael, Mariana Z.; Hodler, Jeurg; Olson, Linda K.; Leopold, George R.; Schulz, Raymond
1997-05-01
Breast ultrasound is a valuable adjunct to mammography but is limited by a very small field of view, particularly with high-resolution transducers necessary for breast diagnosis. We have been developing an ultrasound system based on a diffraction tomography method that provides slices through the breast on a large 20-cm diameter circular field of view. Eight to fifteen images are typically produced in sequential coronal planes from the nipple to the chest wall with either 0.25 or 0.5 mm pixels. As a means to simplify the interpretation of this large set of images, we report experience with 3D life-sized displays of the entire breast of human volunteers using a digital holographic technique. The compound 3D holographic images are produced from the digital image matrix, recorded on 14 X 17 inch transparency and projected on a special white-light viewbox. Holographic visualization of the entire breast has proved to be the preferred method for 3D display of ultrasound computed tomography images. It provides a unique perspective on breast anatomy and may prove useful for biopsy guidance and surgical planning.
Ultrasound-guided cable-free 13-gauge vacuum-assisted biopsy of non-mass breast lesions
Seo, Jiwoon; Jang, Mijung; Yun, Bo La; Lee, Soo Hyun; Kim, Eun-Kyu; Kang, Eunyoung; Park, So Yeon; Moon, Woo Kyung; Choi, Hye Young; Kim, Bohyoung
2017-01-01
Purpose To compare the outcomes of ultrasound-guided core biopsy for non-mass breast lesions by the novel 13-gauge cable-free vacuum-assisted biopsy (VAB) and by the conventional 14-gauge semi-automated core needle biopsy (CCNB). Materials and methods Our institutional review board approved this prospective study, and all patients provided written informed consent. Among 1840 ultrasound-guided percutaneous biopsies performed from August 2013 to December 2014, 145 non-mass breast lesions with suspicious microcalcifications on mammography or corresponding magnetic resonance imaging finding were subjected to 13-gauge VAB or 14-gauge CCNB. We evaluated the technical success rates, average specimen numbers, and tissue sampling time. We also compared the results of percutaneous biopsy and final surgical pathologic diagnosis to analyze the rates of diagnostic upgrade or downgrade. Results Ultrasound-guided VAB successfully targeted and sampled all lesions, whereas CCNB failed to demonstrate calcification in four (10.3%) breast lesions with microcalcification on specimen mammography. The mean sampling time were 238.6 and 170.6 seconds for VAB and CCNB, respectively. No major complications were observed with either method. Ductal carcinoma in situ (DCIS) and atypical ductal hyperplasia (ADH) lesions were more frequently upgraded after CCNB (8/23 and 3/5, respectively) than after VAB (2/26 and 0/4, respectively P = 0.028). Conclusion Non-mass breast lesions were successfully and accurately biopsied using cable-free VAB. The underestimation rate of ultrasound-detected non-mass lesion was significantly lower with VAB than with CCNB. Trial registration CRiS KCT0002267. PMID:28628656
Khelassi, Abdeldjalil
2014-01-01
Active research is being conducted to determine the prognosis for breast cancer. However, the uncertainty is a major obstacle in this domain of medical research. In that context, explanation-aware computing has the potential for providing meaningful interactions between complex medical applications and users, which would ensure a significant reduction of uncertainty and risks. This paper presents an explanation-aware agent, supported by Intensive Knowledge-Distributed Case-Based Reasoning Classifier (IK-DCBRC), to reduce the uncertainty and risks associated with the diagnosis of breast cancer. A meaningful explanation is generated by inferring from a rule-based system according to the level of abstraction and the reasoning traces. The computer-aided detection is conducted by IK-DCBRC, which is a multi-agent system that applies the case-based reasoning paradigm and a fuzzy similarity function for the automatic prognosis by the class of breast tumors, i.e. malignant or benign, from a pattern of cytological images. A meaningful interaction between the physician and the computer-aided diagnosis system, IK-DCBRC, is achieved via an intelligent agent. The physician can observe the trace of reasoning, terms, justifications, and the strategy to be used to decrease the risks and doubts associated with the automatic diagnosis. The capability of the system we have developed was proven by an example in which conflicts were clarified and transparency was ensured. The explanation agent ensures the transparency of the automatic diagnosis of breast cancer supported by IK-DCBRC, which decreases uncertainty and risks and detects some conflicts.
Du, Jing; Li, Xiao-Yu; Hu, He; Xu, Li; Yang, Shi-Ping; Li, Feng-Hua
2018-03-01
Molecularly-targeted contrast enhanced ultrasound (US) imaging is a promising imaging strategy with large potential for improving diagnostic accuracy of conventional US imaging in breast cancer detection. Therefore, we constructed a novel dual-targeted nanosized US contrast agent (UCA) directed at both vascular endothelial growth factor receptor 2 (VEGFR2) and human epidermal growth factor receptor 2 (HER2) based on perfluoropropane (C 3 F 8 )-filled poly(lactic-co-glycolic acid) (PLGA) (NBs) for breast cancer detection. In vitro, single- or dual-targeted PLGA NBs showed high target specificities and better effects of target enhancement in VEGFR2 or HER2-positive cells. In vivo, US imaging signal in the murine breast cancer model was significantly higher (P < 0.01) for dual-targeted NBs than single-targeted and non-targeted NBs. Small animal fluorescence imaging further confirmed the special affinity of the dual-targeted nanosized contrast agent to both VEGFR2 and HER2. Immunofluorescence and immunohistochemistry staining confirmed the expressions of VEGFR2 and HER2 on tumor neovasculature and tumor cells of breast cancer. In conclusions, the feasibility of using dual-targeted PLGA NBs to enhance ultrasonic images is demonstrated in vitro and in vivo. This may be a promising approach to target biomarkers of breast cancer for two site-specific US molecular imaging.
NASA Astrophysics Data System (ADS)
Erickson-Bhatt, Sarah J.; Nolan, Ryan; Shemonski, Nathan D.; Adie, Steven G.; Putney, Jeffrey; Darga, Donald; McCormick, Daniel T.; Cittadine, Andrew; Marjanovic, Marina; Chaney, Eric J.; Monroy, Guillermo L.; South, Fredrick; Carney, P. Scott; Cradock, Kimberly A.; Liu, Z. George; Ray, Partha S.; Boppart, Stephen A.
2014-02-01
Breast-conserving surgery is a frequent option for women with stage I and II breast cancer, and with radiation treatment, can be as effective as a mastectomy. However, adequate margin detection remains a challenge, and too often additional surgeries are required. Optical coherence tomography (OCT) provides a potential method for real-time, high-resolution imaging of breast tissue during surgery. Intra-operative OCT imaging of excised breast tissues has been previously demonstrated by several groups. In this study, a novel handheld surgical probe-based OCT system is introduced, which was used by the surgeon to image in vivo, within the tumor cavity, and immediately following tumor removal in order to detect the presence of any remaining cancer. Following resection, study investigators imaged the excised tissue with the same probe for comparison. We present OCT images obtained from over 15 patients during lumpectomy and mastectomy surgeries. Images were compared to post-operative histopathology for diagnosis. OCT images with micron scale resolution show areas of heterogeneity and disorganized features indicative of malignancy, compared to more uniform regions of normal tissue. Video-rate acquisition shows the inside of the tumor cavity as the surgeon sweeps the probe along the walls of the surgical cavity. This demonstrates the potential of OCT for real-time assessment of surgical tumor margins and for reducing the unacceptably high re-operation rate for breast cancer patients.
Filipovic, Nenad D.
2017-01-01
Image segmentation is one of the most common procedures in medical imaging applications. It is also a very important task in breast cancer detection. Breast cancer detection procedure based on mammography can be divided into several stages. The first stage is the extraction of the region of interest from a breast image, followed by the identification of suspicious mass regions, their classification, and comparison with the existing image database. It is often the case that already existing image databases have large sets of data whose processing requires a lot of time, and thus the acceleration of each of the processing stages in breast cancer detection is a very important issue. In this paper, the implementation of the already existing algorithm for region-of-interest based image segmentation for mammogram images on High-Performance Reconfigurable Dataflow Computers (HPRDCs) is proposed. As a dataflow engine (DFE) of such HPRDC, Maxeler's acceleration card is used. The experiments for examining the acceleration of that algorithm on the Reconfigurable Dataflow Computers (RDCs) are performed with two types of mammogram images with different resolutions. There were, also, several DFE configurations and each of them gave a different acceleration value of algorithm execution. Those acceleration values are presented and experimental results showed good acceleration. PMID:28611851
Milankovic, Ivan L; Mijailovic, Nikola V; Filipovic, Nenad D; Peulic, Aleksandar S
2017-01-01
Image segmentation is one of the most common procedures in medical imaging applications. It is also a very important task in breast cancer detection. Breast cancer detection procedure based on mammography can be divided into several stages. The first stage is the extraction of the region of interest from a breast image, followed by the identification of suspicious mass regions, their classification, and comparison with the existing image database. It is often the case that already existing image databases have large sets of data whose processing requires a lot of time, and thus the acceleration of each of the processing stages in breast cancer detection is a very important issue. In this paper, the implementation of the already existing algorithm for region-of-interest based image segmentation for mammogram images on High-Performance Reconfigurable Dataflow Computers (HPRDCs) is proposed. As a dataflow engine (DFE) of such HPRDC, Maxeler's acceleration card is used. The experiments for examining the acceleration of that algorithm on the Reconfigurable Dataflow Computers (RDCs) are performed with two types of mammogram images with different resolutions. There were, also, several DFE configurations and each of them gave a different acceleration value of algorithm execution. Those acceleration values are presented and experimental results showed good acceleration.
Pulsed terahertz imaging of breast cancer in freshly excised murine tumors
NASA Astrophysics Data System (ADS)
Bowman, Tyler; Chavez, Tanny; Khan, Kamrul; Wu, Jingxian; Chakraborty, Avishek; Rajaram, Narasimhan; Bailey, Keith; El-Shenawee, Magda
2018-02-01
This paper investigates terahertz (THz) imaging and classification of freshly excised murine xenograft breast cancer tumors. These tumors are grown via injection of E0771 breast adenocarcinoma cells into the flank of mice maintained on high-fat diet. Within 1 h of excision, the tumor and adjacent tissues are imaged using a pulsed THz system in the reflection mode. The THz images are classified using a statistical Bayesian mixture model with unsupervised and supervised approaches. Correlation with digitized pathology images is conducted using classification images assigned by a modal class decision rule. The corresponding receiver operating characteristic curves are obtained based on the classification results. A total of 13 tumor samples obtained from 9 tumors are investigated. The results show good correlation of THz images with pathology results in all samples of cancer and fat tissues. For tumor samples of cancer, fat, and muscle tissues, THz images show reasonable correlation with pathology where the primary challenge lies in the overlapping dielectric properties of cancer and muscle tissues. The use of a supervised regression approach shows improvement in the classification images although not consistently in all tissue regions. Advancing THz imaging of breast tumors from mice and the development of accurate statistical models will ultimately progress the technique for the assessment of human breast tumor margins.
Park, Samuel Byeongjun; Kim, Jung-Gun; Lim, Ki-Woong; Yoon, Chae-Hyun; Kim, Dong-Jun; Kang, Han-Sung; Jo, Yung-Ho
2017-08-01
We developed an image-guided intervention robot system that can be operated in a magnetic resonance (MR) imaging gantry. The system incorporates a bendable needle intervention robot for breast cancer patients that overcomes the space limitations of the MR gantry. Most breast coil designs for breast MR imaging have side openings to allow manual localization. However, for many intervention procedures, the patient must be removed from the gantry. A robotic manipulation system with integrated image guidance software was developed. Our robotic manipulator was designed to be slim, so as to fit between the patient's side and the MR gantry wall. Only non-magnetic materials were used, and an electromagnetic shield was employed for cables and circuits. The image guidance software was built using open source libraries. In situ feasibility tests were performed in a 3-T MR system. One target point in the breast phantom was chosen by the clinician for each experiment, and our robot moved the needle close to the target point. Without image-guided feedback control, the needle end could not hit the target point (distance = 5 mm) in the first experiment. Using our robotic system, the needle hits the target lesion of the breast phantom at a distance of 2.3 mm from the same target point using image-guided feedback. The second experiment was performed using other target points, and the distance between the final needle end point and the target point was 0.8 mm. We successfully developed an MR-guided needle intervention robot for breast cancer patients. Further research will allow the expansion of these interventions.
Simulation of breast compression in mammography using finite element analysis: A preliminary study
NASA Astrophysics Data System (ADS)
Liu, Yan-Lin; Liu, Pei-Yuan; Huang, Mei-Lan; Hsu, Jui-Ting; Han, Ruo-Ping; Wu, Jay
2017-11-01
Adequate compression during mammography lowers the absorbed dose in the breast and improves the image quality. The compressed breast thickness (CBT) is affected by various factors, such as breast volume, glandularity, and compression force. In this study, we used the finite element analysis to simulate breast compression and deformation and validated the simulated CBT with clinical mammography results. Image data from ten subjects who had undergone mammography screening and breast magnetic resonance imaging (MRI) were collected, and their breast models were created according to the MR images. The non-linear tissue deformation under 10-16 daN in the cranial-caudal direction was simulated. When the clinical compression force was used, the simulated CBT ranged from 2.34 to 5.90 cm. The absolute difference between the simulated CBT and the clinically measured CBT ranged from 0.5 to 7.1 mm. The simulated CBT had a strong positive linear relationship to breast volume and a weak negative correlation to glandularity. The average simulated CBT under 10, 12, 14, and 16 daN was 5.68, 5.12, 4.67, and 4.25 cm, respectively. Through this study, the relationships between CBT, breast volume, glandularity, and compression force are provided for use in clinical mammography.
Analysis of breast thermograms using Gabor wavelet anisotropy index.
Suganthi, S S; Ramakrishnan, S
2014-09-01
In this study, an attempt is made to distinguish the normal and abnormal tissues in breast thermal images using Gabor wavelet transform. Thermograms having normal, benign and malignant tissues are considered in this study and are obtained from public online database. Segmentation of breast tissues is performed by multiplying raw image and ground truth mask. Left and right breast regions are separated after removing the non-breast regions from the segmented image. Based on the pathological conditions, the separated breast regions are grouped as normal and abnormal tissues. Gabor features such as energy and amplitude in different scales and orientations are extracted. Anisotropy and orientation measures are calculated from the extracted features and analyzed. A distinctive variation is observed among different orientations of the extracted features. It is found that the anisotropy measure is capable of differentiating the structural changes due to varied metabolic conditions. Further, the Gabor features also showed relative variations among different pathological conditions. It appears that these features can be used efficiently to identify normal and abnormal tissues and hence, improve the relevance of breast thermography in early detection of breast cancer and content based image retrieval.
Simos, Demetrios; Hutton, Brian; Graham, Ian D; Arnaout, Angel; Caudrelier, Jean-Michel; Clemons, Mark
2015-02-01
Despite multiple guidelines advocating against routine radiological evaluation for metastases in women with early stage breast cancer, imaging is still frequently overused. The objective of this study was to assess doctor's views on imaging guidelines, and an attempt to establish why personal and local clinical practice patterns regarding imaging may differ from current guidelines. Canadian doctors who treat breast cancer were invited by email to complete an online survey developed by members of the research team. Responses were received from 173 physicians (26% response rate). Most (82%) indicated awareness of at least one published imaging guideline. Sixty per cent indicated that they had read the recommendations of the 2012 American Society of Clinical Oncology 'Top 5' list for choosing wisely in oncology imaging and, of those, 81% agreed with it. However, most indicated that this recommendation has not influenced them to order less imaging. Over 95% of doctors identified suspicious history, physical examination findings and inflammatory breast cancer as important factors for performing imaging. The majority did not feel that patient demand, fear of litigation or ease of access to imaging influenced their ordering for imaging. The majority of breast cancer doctors are aware of and generally agree that guidelines pertaining to staging imaging for early breast cancer are reflective of evidence. Despite this, adherence is variable and factors such as local practice patterns and disease biology may play a role. Alternative strategies, beyond simply publishing recommendations, are therefore required if there is to be a sustained change in doctor behaviour. © 2014 John Wiley & Sons, Ltd.
Computer-aided classification of breast masses using contrast-enhanced digital mammograms
NASA Astrophysics Data System (ADS)
Danala, Gopichandh; Aghaei, Faranak; Heidari, Morteza; Wu, Teresa; Patel, Bhavika; Zheng, Bin
2018-02-01
By taking advantages of both mammography and breast MRI, contrast-enhanced digital mammography (CEDM) has emerged as a new promising imaging modality to improve efficacy of breast cancer screening and diagnosis. The primary objective of study is to develop and evaluate a new computer-aided detection and diagnosis (CAD) scheme of CEDM images to classify between malignant and benign breast masses. A CEDM dataset consisting of 111 patients (33 benign and 78 malignant) was retrospectively assembled. Each case includes two types of images namely, low-energy (LE) and dual-energy subtracted (DES) images. First, CAD scheme applied a hybrid segmentation method to automatically segment masses depicting on LE and DES images separately. Optimal segmentation results from DES images were also mapped to LE images and vice versa. Next, a set of 109 quantitative image features related to mass shape and density heterogeneity was initially computed. Last, four multilayer perceptron-based machine learning classifiers integrated with correlationbased feature subset evaluator and leave-one-case-out cross-validation method was built to classify mass regions depicting on LE and DES images, respectively. Initially, when CAD scheme was applied to original segmentation of DES and LE images, the areas under ROC curves were 0.7585+/-0.0526 and 0.7534+/-0.0470, respectively. After optimal segmentation mapping from DES to LE images, AUC value of CAD scheme significantly increased to 0.8477+/-0.0376 (p<0.01). Since DES images eliminate overlapping effect of dense breast tissue on lesions, segmentation accuracy was significantly improved as compared to regular mammograms, the study demonstrated that computer-aided classification of breast masses using CEDM images yielded higher performance.
SU-C-207B-04: Automated Segmentation of Pectoral Muscle in MR Images of Dense Breasts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Verburg, E; Waard, SN de; Veldhuis, WB
Purpose: To develop and evaluate a fully automated method for segmentation of the pectoral muscle boundary in Magnetic Resonance Imaging (MRI) of dense breasts. Methods: Segmentation of the pectoral muscle is an important part of automatic breast image analysis methods. Current methods for segmenting the pectoral muscle in breast MRI have difficulties delineating the muscle border correctly in breasts with a large proportion of fibroglandular tissue (i.e., dense breasts). Hence, an automated method based on dynamic programming was developed, incorporating heuristics aimed at shape, location and gradient features.To assess the method, the pectoral muscle was segmented in 91 randomly selectedmore » participants (mean age 56.6 years, range 49.5–75.2 years) from a large MRI screening trial in women with dense breasts (ACR BI-RADS category 4). Each MR dataset consisted of 178 or 179 T1-weighted images with voxel size 0.64 × 0.64 × 1.00 mm3. All images (n=16,287) were reviewed and scored by a radiologist. In contrast to volume overlap coefficients, such as DICE, the radiologist detected deviations in the segmented muscle border and determined whether the result would impact the ability to accurately determine the volume of fibroglandular tissue and detection of breast lesions. Results: According to the radiologist’s scores, 95.5% of the slices did not mask breast tissue in such way that it could affect detection of breast lesions or volume measurements. In 13.1% of the slices a deviation in the segmented muscle border was present which would not impact breast lesion detection. In 70 datasets (78%) at least 95% of the slices were segmented in such a way it would not affect detection of breast lesions, and in 60 (66%) datasets this was 100%. Conclusion: Dynamic programming with dedicated heuristics shows promising potential to segment the pectoral muscle in women with dense breasts.« less
NASA's Technology Transfer Program for the Early Detection of Breast Cancer
NASA Technical Reports Server (NTRS)
Schmidt, Gregory; Frey, Mary Anne; Vernikos, Joan; Winfield, Daniel; Dalton, Bonnie P. (Technical Monitor)
1996-01-01
The National Aeronautics and Space Administration (NASA) has led the development of advanced imaging sensors and image processing technologies for space science and Earth science missions. NASA considers the transfer and commercialization of such technologies a fundamental mission of the agency. Over the last two years, efforts have been focused on the application of aerospace imaging and computing to the field of diagnostic imaging, specifically to breast cancer imaging. These technology transfer efforts offer significant promise in helping in the national public health priority of the early detection of breast cancer.
2008-03-01
CONTRACT NUMBER Detection and Evaluation of Early Breast Cancer via Magnetic Resonance Imaging: Studies of Mouse Models and Clinical Implementation...research proposed here can directly lead to clinical improvements in both early breast cancer detection, as well as effective breast cancer therapy. To date... cancer is a major prognostic factor in the management of the disease. In particular, detecting breast cancer in its pre-invasive form as ductal carcinoma
Optical Breast Shape Capture and Finite Element Mesh Generation for Electrical Impedance Tomography
Forsyth, J.; Borsic, A.; Halter, R.J.; Hartov, A.; Paulsen, K.D.
2011-01-01
X-Ray mammography is the standard for breast cancer screening. The development of alternative imaging modalities is desirable because Mammograms expose patients to ionizing radiation. Electrical Impedance Tomography (EIT) may be used to determine tissue conductivity, a property which is an indicator of cancer presence. EIT is also a low-cost imaging solution and does not involve ionizing radiation. In breast EIT, impedance measurements are made using electrodes placed on the surface of the patient’s breast. The complex conductivity of the volume of the breast is estimated by a reconstruction algorithm. EIT reconstruction is a severely ill-posed inverse problem. As a result, noisy instrumentation and incorrect modelling of the electrodes and domain shape produce significant image artefacts. In this paper, we propose a method that has the potential to reduce these errors by accurately modelling the patient breast shape. A 3D hand-held optical scanner is used to acquire the breast geometry and electrode positions. We develop methods for processing the data from the scanner and producing volume meshes accurately matching the breast surface and electrode locations, which can be used for image reconstruction. We demonstrate this method for a plaster breast phantom and a human subject. Using this approach will allow patient-specific finite element meshes to be generated which has the potential to improve the clinical value of EIT for breast cancer diagnosis. PMID:21646711
Breast cancer detection using time reversal
NASA Astrophysics Data System (ADS)
Sheikh Sajjadieh, Mohammad Hossein
Breast cancer is the second leading cause of cancer death after lung cancer among women. Mammography and magnetic resonance imaging (MRI) have certain limitations in detecting breast cancer, especially during its early stage of development. A number of studies have shown that microwave breast cancer detection has potential to become a successful clinical complement to the conventional X-ray mammography. Microwave breast imaging is performed by illuminating the breast tissues with an electromagnetic waveform and recording its reflections (backscatters) emanating from variations in the normal breast tissues and tumour cells, if present, using an antenna array. These backscatters, referred to as the overall (tumour and clutter) response, are processed to estimate the tumour response, which is applied as input to array imaging algorithms used to estimate the location of the tumour. Due to changes in the breast profile over time, the commonly utilized background subtraction procedures used to estimate the target (tumour) response in array processing are impractical for breast cancer detection. The thesis proposes a new tumour estimation algorithm based on a combination of the data adaptive filter with the envelope detection filter (DAF/EDF), which collectively do not require a training step. After establishing the superiority of the DAF/EDF based approach, the thesis shows that the time reversal (TR) array imaging algorithms outperform their conventional conterparts in detecting and localizing tumour cells in breast tissues at SNRs ranging from 15 to 30dB.
Berger, Frank; Sam Gambhir, Sanjiv
2001-01-01
A variety of imaging technologies is being investigated as tools for studying gene expression in living subjects. Two technologies that use radiolabeled isotopes are single photon emission computed tomography (SPECT) and positron emission tomography (PET). A relatively high sensitivity, a full quantitative tomographic capability, and the ability to extend small animal imaging assays directly into human applications characterize radionuclide approaches. Various radiolabeled probes (tracers) can be synthesized to target specific molecules present in breast cancer cells. These include antibodies or ligands to target cell surface receptors, substrates for intracellular enzymes, antisense oligodeoxynucleotide probes for targeting mRNA, probes for targeting intracellular receptors, and probes for genes transferred into the cell. We briefly discuss each of these imaging approaches and focus in detail on imaging reporter genes. In a PET reporter gene system for in vivo reporter gene imaging, the protein products of the reporter genes sequester positron emitting reporter probes. PET subsequently measures the PET reporter gene dependent sequestration of the PET reporter probe in living animals. We describe and review reporter gene approaches using the herpes simplex type 1 virus thymidine kinase and the dopamine type 2 receptor genes. Application of the reporter gene approach to animal models for breast cancer is discussed. Prospects for future applications of the transgene imaging technology in human gene therapy are also discussed. Both SPECT and PET provide unique opportunities to study animal models of breast cancer with direct application to human imaging. Continued development of new technology, probes and assays should help in the better understanding of basic breast cancer biology and in the improved management of breast cancer patients. PMID:11250742
Fu, Yong; Ji, Zhong; Ding, Wenzheng; Ye, Fanghao; Lou, Cunguang
2014-11-01
Previous studies demonstrated that thermoacoustic imaging (TAI) has great potential for breast tumor detection. However, large field of view (FOV) imaging remains a long-standing challenge for three-dimensional (3D) breast tumor localization. Here, the authors propose a practical TAI system for noninvasive 3D localization of breast tumors with large FOV through the use of ultrashort microwave pulse (USMP). A USMP generator was employed for TAI. The energy density required for quality imaging and the corresponding microwave-to-acoustic conversion efficiency were compared with that of conventional TAI. The microwave energy distribution, imaging depth, resolution, and 3D imaging capabilities were then investigated. Finally, a breast phantom embedded with a laboratory-grown tumor was imaged to evaluate the FOV performance of the USMP TAI system, under a simulated clinical situation. A radiation energy density equivalent to just 1.6%-2.2% of that for conventional submicrosecond microwave TAI was sufficient to obtain a thermoacoustic signal with the required signal-to-noise ratio. This result clearly demonstrated a significantly higher microwave-to-acoustic conversion efficiency of USMP TAI compared to that of conventional TAI. The USMP TAI system achieved 61 mm imaging depth and 12 × 12 cm(2) microwave radiation area. The volumetric image of a copper target measured at depth of 4-6 cm matched well with the actual shape and the resolution reaches 230 μm. The TAI of the breast phantom was precisely localized to an accuracy of 0.1 cm over an 8 × 8 cm(2) FOV. The experimental results demonstrated that the USMP TAI system offered significant potential for noninvasive clinical detection and 3D localization of deep breast tumors, with low microwave radiation dose and high spatial resolution over a sufficiently large FOV.
Automated breast segmentation in ultrasound computer tomography SAFT images
NASA Astrophysics Data System (ADS)
Hopp, T.; You, W.; Zapf, M.; Tan, W. Y.; Gemmeke, H.; Ruiter, N. V.
2017-03-01
Ultrasound Computer Tomography (USCT) is a promising new imaging system for breast cancer diagnosis. An essential step before further processing is to remove the water background from the reconstructed images. In this paper we present a fully-automated image segmentation method based on three-dimensional active contours. The active contour method is extended by applying gradient vector flow and encoding the USCT aperture characteristics as additional weighting terms. A surface detection algorithm based on a ray model is developed to initialize the active contour, which is iteratively deformed to capture the breast outline in USCT reflection images. The evaluation with synthetic data showed that the method is able to cope with noisy images, and is not influenced by the position of the breast and the presence of scattering objects within the breast. The proposed method was applied to 14 in-vivo images resulting in an average surface deviation from a manual segmentation of 2.7 mm. We conclude that automated segmentation of USCT reflection images is feasible and produces results comparable to a manual segmentation. By applying the proposed method, reproducible segmentation results can be obtained without manual interaction by an expert.
Alignment of multimodality, 2D and 3D breast images
NASA Astrophysics Data System (ADS)
Grevera, George J.; Udupa, Jayaram K.
2003-05-01
In a larger effort, we are studying methods to improve the specificity of the diagnosis of breast cancer by combining the complementary information available from multiple imaging modalities. Merging information is important for a number of reasons. For example, contrast uptake curves are an indication of malignancy. The determination of anatomical locations in corresponding images from various modalities is necessary to ascertain the extent of regions of tissue. To facilitate this fusion, registration becomes necessary. We describe in this paper a framework in which 2D and 3D breast images from MRI, PET, Ultrasound, and Digital Mammography can be registered to facilitate this goal. Briefly, prior to image acquisition, an alignment grid is drawn on the breast skin. Modality-specific markers are then placed at the indicated grid points. Images are then acquired by a specific modality with the modality specific external markers in place causing the markers to appear in the images. This is the first study that we are aware of that has undertaken the difficult task of registering 2D and 3D images of such a highly deformable (the breast) across such a wide variety of modalities. This paper reports some very preliminary results from this project.
Image enhancement in positron emission mammography
NASA Astrophysics Data System (ADS)
Slavine, Nikolai V.; Seiler, Stephen; McColl, Roderick W.; Lenkinski, Robert E.
2017-02-01
Purpose: To evaluate an efficient iterative deconvolution method (RSEMD) for improving the quantitative accuracy of previously reconstructed breast images by commercial positron emission mammography (PEM) scanner. Materials and Methods: The RSEMD method was tested on breast phantom data and clinical PEM imaging data. Data acquisition was performed on a commercial Naviscan Flex Solo II PEM camera. This method was applied to patient breast images previously reconstructed with Naviscan software (MLEM) to determine improvements in resolution, signal to noise ratio (SNR) and contrast to noise ratio (CNR.) Results: In all of the patients' breast studies the post-processed images proved to have higher resolution and lower noise as compared with images reconstructed by conventional methods. In general, the values of SNR reached a plateau at around 6 iterations with an improvement factor of about 2 for post-processed Flex Solo II PEM images. Improvements in image resolution after the application of RSEMD have also been demonstrated. Conclusions: A rapidly converging, iterative deconvolution algorithm with a novel resolution subsets-based approach RSEMD that operates on patient DICOM images has been used for quantitative improvement in breast imaging. The RSEMD method can be applied to clinical PEM images to improve image quality to diagnostically acceptable levels and will be crucial in order to facilitate diagnosis of tumor progression at the earliest stages. The RSEMD method can be considered as an extended Richardson-Lucy algorithm with multiple resolution levels (resolution subsets).
Automatic nipple detection on 3D images of an automated breast ultrasound system (ABUS)
NASA Astrophysics Data System (ADS)
Javanshir Moghaddam, Mandana; Tan, Tao; Karssemeijer, Nico; Platel, Bram
2014-03-01
Recent studies have demonstrated that applying Automated Breast Ultrasound in addition to mammography in women with dense breasts can lead to additional detection of small, early stage breast cancers which are occult in corresponding mammograms. In this paper, we proposed a fully automatic method for detecting the nipple location in 3D ultrasound breast images acquired from Automated Breast Ultrasound Systems. The nipple location is a valuable landmark to report the position of possible abnormalities in a breast or to guide image registration. To detect the nipple location, all images were normalized. Subsequently, features have been extracted in a multi scale approach and classification experiments were performed using a gentle boost classifier to identify the nipple location. The method was applied on a dataset of 100 patients with 294 different 3D ultrasound views from Siemens and U-systems acquisition systems. Our database is a representative sample of cases obtained in clinical practice by four medical centers. The automatic method could accurately locate the nipple in 90% of AP (Anterior-Posterior) views and in 79% of the other views.
Sabiston, Catherine M; Rusticus, Shayna; Brunet, Jennifer; McDonough, Meghan H; Hadd, Valerie; Hubley, Anita M; Crocker, Peter R E
2010-10-01
To examine whether the meaning and interpretation of body image are similar for breast cancer survivors and women without breast cancer. Women completed the Multidimensional Body Self-Relations Questionnaire--Appearance Scales as part of two studies. There were 469 women with breast cancer and 385 women without breast cancer. Invariance testing was conducted to examine whether the items assessing the body image dimensions were similar, whether the dimensions were interpreted similarly, whether the items were equally salient and meaningful, and whether there were mean differences on the body image dimensions across the two groups. The meaning and interpretation of body image dimensions related to appearance evaluation and appearance orientation were similar across the groups, yet some group differences were found for overweight preoccupation and body areas satisfaction (and not testable for self-classified weight). Breast cancer survivors reported a small yet significantly higher mean on appearance evaluation and lower mean on appearance orientation compared to the women without breast cancer. Meaningful comparisons in body image across cancer and non-cancer women can be made using two of the Multidimensional Body Self-Relations Questionnaire--Appearance Scales. The overweight preoccupation subscale could be used to assess body image but should not be used if group mean differences are desirable. Assessing satisfaction with body areas across these groups is not recommended and may introduce systematic bias.
Vaughan, Christopher L; Douglas, Tania S; Said-Hartley, Qonita; Baasch, Roland V; Boonzaier, James A; Goemans, Brian C; Harverson, John; Mingay, Michael W; Omar, Shuaib; Smith, Raphael V; Venter, Nielen C; Wilson, Heidi S
2015-01-01
Purpose The aim of this study was to test a novel dual-modality imaging system that combines full-field digital mammography (FFDM) and automated breast ultrasound (ABUS) in a single platform. Our Aceso system, named after the Greek goddess of healing, was specifically designed for the early detection of cancer in women with dense breast tissue. Materials and Methods Aceso was first tested using two industry standards: a CDMAM phantom as endorsed by EUREF was used to assess the FFDM images; and the CIRS 040GSE ultrasound phantom was imaged to evaluate the quality of the ABUS images. In addition, 58 women participated in a clinical trial: 51 were healthy volunteers aged between 40 and 65, while 7 were patients referred by the breast clinic, 6 of whom had biopsy-proven breast cancer. Results The CDMAM tests showed that the FFDM results were “acceptable” but fell short of “achievable” which was attributed to the low dose used. The ABUS images had good depth penetration (80 mm) and adequate axial resolution (0.5 mm) but the lateral resolution of 2 mm was judged to be too coarse. In a 42-year old volunteer with extremely dense breast tissue, the ABUS modality detected a lesion (a benign cyst) that was mammographically occult in the FFDM image. For a 73-year old patient with fatty breasts, a malignant lesion was successfully detected and co-registered in the FFDM and ABUS images. On average, each woman spent less than 11 minutes in the acquisition room. Conclusions While there is room for improvement in the quality of both the FFDM and ABUS images, Aceso has demonstrated its ability to acquire clinically meaningful images for a range of women with varying breast densities and therefore has potential as a screening device. PMID:27133694
Determination of female breast tumor and its parameter estimation by thermal simulation
NASA Astrophysics Data System (ADS)
Chen, Xin-guang; Xu, A.-qing; Yang, Hong-qin; Wang, Yu-hua; Xie, Shu-sen
2010-02-01
Thermal imaging is an emerging method for early detection of female breast tumor. The main challenge for thermal imaging used in breast clinics lies in how to detect or locate the tumor and obtain its related parameters. The purpose of this study is to apply an improved method which combined a genetic algorithm with finite element thermal analysis to determine the breast tumor and its parameters, such as the size, location, metabolic heat generation and blood perfusion rate. A finite element model for breast embedded a tumor was used to investigate the temperature distribution, and then the influences of tumor metabolic heat generation, tumor location and tumor size on the temperature were studied by use of an improved genetic algorithm. The results show that thermal imaging is a potential and effective detection tool for early breast tumor, and thermal simulation may be helpful for the explanation of breast thermograms.
Stationary Digital Tomosynthesis System for Early Detection of Breast Tumors
2011-05-01
selenium flat panel detector. Proc. SPIE 2005. 5745: p. 529-540 4. Kopans, D.B., Breast Imaging. 2 ed. 1997, New York Lippincott Williams and...same. 2005. 8. M. Bissonnette, et al. Digital breast tomosynthesis using an amorphous selenium flat panel detector. in Medical Imaging 2005...tomosynthesis system with selenium based flat panel detector. Proc of SPIE, Physics of Medical Imaging, 2005. 5745. 12
Mir, R.; Johnson, H.; Mathur, R.; Wise, L.; Kahn, L. B.
1995-01-01
The proliferative index of 63 breast carcinomas was measured on Ki-67 immunostained frozen tissue sections with a computer-assisted image analysis system. The mean proliferative index in estrogen-positive breast carcinomas was lower than in estrogen-negative carcinomas. An inverse relationship between proliferative index and short-term disease-free survival was noted. Images Figure 1 Figure 2 PMID:7674345
Model-based position correlation between breast images
NASA Astrophysics Data System (ADS)
Georgii, J.; Zöhrer, F.; Hahn, H. K.
2013-02-01
Nowadays, breast diagnosis is based on images of different projections and modalities, such that sensitivity and specificity of the diagnosis can be improved. However, this emburdens radiologists to find corresponding locations in these data sets, which is a time consuming task, especially since the resolution of the images increases and thus more and more data have to be considered in the diagnosis. Therefore, we aim at support radiologist by automatically synchronizing cursor positions between different views of the breast. Specifically, we present an automatic approach to compute the spatial correlation between MLO and CC mammogram or tomosynthesis projections of the breast. It is based on pre-computed finite element simulations of generic breast models, which are adapted to the patient-specific breast using a contour mapping approach. Our approach is designed to be fully automatic and efficient, such that it can be implemented directly into existing multimodal breast workstations. Additionally, it is extendable to support other breast modalities in future, too.
MO-FG-209-05: Towards a Feature-Based Anthropomorphic Model Observer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Avanaki, A.
2016-06-15
This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, andmore » radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Graff, C.
This symposium will review recent advances in the simulation methods for evaluation of novel breast imaging systems – the subject of AAPM Task Group TG234. Our focus will be on the various approaches to development and validation of software anthropomorphic phantoms and their use in the statistical assessment of novel imaging systems using such phantoms along with computational models for the x-ray image formation process. Due to the dynamic development and complex design of modern medical imaging systems, the simulation of anatomical structures, image acquisition modalities, and the image perception and analysis offers substantial benefits of reduced cost, duration, andmore » radiation exposure, as well as the known ground-truth and wide variability in simulated anatomies. For these reasons, Virtual Clinical Trials (VCTs) have been increasingly accepted as a viable tool for preclinical assessment of x-ray and other breast imaging methods. Activities of TG234 have encompassed the optimization of protocols for simulation studies, including phantom specifications, the simulated data representation, models of the imaging process, and statistical assessment of simulated images. The symposium will discuss the state-of-the-science of VCTs for novel breast imaging systems, emphasizing recent developments and future directions. Presentations will discuss virtual phantoms for intermodality breast imaging performance comparisons, extension of the breast anatomy simulation to the cellular level, optimized integration of the simulated imaging chain, and the novel directions in the observer models design. Learning Objectives: Review novel results in developing and applying virtual phantoms for inter-modality breast imaging performance comparisons; Discuss the efforts to extend the computer simulation of breast anatomy and pathology to the cellular level; Summarize the state of the science in optimized integration of modules in the simulated imaging chain; Compare novel directions in the design of observer models for task based validation of imaging systems. PB: Research funding support from the NIH, NSF, and Komen for the Cure; NIH funded collaboration with Barco, Inc. and Hologic, Inc.; Consultant to Delaware State Univ. and NCCPM, UK. AA: Employed at Barco Healthcare.; P. Bakic, NIH: (NIGMS P20 #GM103446, NCI R01 #CA154444); M. Das, NIH Research grants.« less
Vision 20/20: Mammographic breast density and its clinical applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ng, Kwan-Hoong, E-mail: ngkh@ummc.edu.my; Lau, Susie
2015-12-15
Breast density is a strong predictor of the failure of mammography screening to detect breast cancer and is a strong predictor of the risk of developing breast cancer. The many imaging options that are now available for imaging dense breasts show great promise, but there is still the question of determining which women are “dense” and what imaging modality is suitable for individual women. To date, mammographic breast density has been classified according to the Breast Imaging-Reporting and Data System (BI-RADS) categories from visual assessment, but this is known to be very subjective. Despite many research reports, the authors believemore » there has been a lack of physics-led and evidence-based arguments about what breast density actually is, how it should be measured, and how it should be used. In this paper, the authors attempt to start correcting this situation by reviewing the history of breast density research and the debates generated by the advocacy movement. The authors review the development of breast density estimation from pattern analysis to area-based analysis, and the current automated volumetric breast density (VBD) analysis. This is followed by a discussion on seeking the ground truth of VBD and mapping volumetric methods to BI-RADS density categories. The authors expect great improvement in VBD measurements that will satisfy the needs of radiologists, epidemiologists, surgeons, and physicists. The authors believe that they are now witnessing a paradigm shift toward personalized breast screening, which is going to see many more cancers being detected early, with the use of automated density measurement tools as an important component.« less
Tekbas, Guven; Ince, Tülay; Kapan, Murat; Ekici, Faysal; Önder, Akin; Kucukonen, Mehmet; Bilici, Aslan; Gumus, Hatice
2012-01-01
Background This article is concerned with the evaluation of an adolescent breast mass using imaging methods. Case Report A 14-year-old girl presented with progressive asymmetric enlargement of the left breast. She had felt a breast lump about 4 months earlier, and over the last 2 months it had been growing progressively. Tumor markers, including AFP, CEA, CA15-3, and CA125, were all normal. Ultrasonography showed a hypoechoichyperechoic, solid mass. Magnetic resonance imaging of the breast revealed a well marginated mass with hypointensity on T1-weighted images and mild hyperintensity on T2-weighted images, which showed mild contrast uptake. Biopsy revealed an undifferentiated malignant mesenchymal sarcoma. The patient underwent mastectomy with axillary lymph node sampling. After the operation, she received 3 cycles of chemotherapy and radiotherapy. Conclusion Due to the rarity of breast sarcoma and inadequate imaging methods to establish an exact diagnosis, radiologists and clinicians may misdiagnose and merely follow these tumors. As in our case, the histology of the patient may be the leading factor in the management of these tumors. Even in very young patients, progressively growing breast masses should alert the clinician to check for malignancy verified by biopsy. PMID:22740802
Uematsu, Takayoshi
2017-01-01
This article discusses possible supplemental breast cancer screening modalities for younger women with dense breasts from a perspective of population-based breast cancer screening program in Japan. Supplemental breast cancer screening modalities have been proposed to increase the sensitivity and detection rates of early stage breast cancer in women with dense breasts; however, there are no global guidelines that recommend the use of supplemental breast cancer screening modalities in such women. Also, no criterion standard exists for breast density assessment. Based on the current situation of breast imaging in Japan, the possible supplemental breast cancer screening modalities are ultrasonography, digital breast tomosynthesis, and breast magnetic resonance imaging. An appropriate population-based breast cancer screening program based on the balance between cost and benefit should be a high priority. Further research based on evidence-based medicine is encouraged. It is very important that the ethnicity, workforce, workflow, and resources for breast cancer screening in each country should be considered when considering supplemental breast cancer screening modalities for women with dense breasts.
Yao, Xinwen; Gan, Yu; Chang, Ernest; Hibshoosh, Hanina; Feldman, Sheldon; Hendon, Christine
2017-03-01
Breast cancer is one of the most common cancers, and recognized as the third leading cause of mortality in women. Optical coherence tomography (OCT) enables three dimensional visualization of biological tissue with micrometer level resolution at high speed, and can play an important role in early diagnosis and treatment guidance of breast cancer. In particular, ultra-high resolution (UHR) OCT provides images with better histological correlation. This paper compared UHR OCT performance with standard OCT in breast cancer imaging qualitatively and quantitatively. Automatic tissue classification algorithms were used to automatically detect invasive ductal carcinoma in ex vivo human breast tissue. Human breast tissues, including non-neoplastic/normal tissues from breast reduction and tumor samples from mastectomy specimens, were excised from patients at Columbia University Medical Center. The tissue specimens were imaged by two spectral domain OCT systems at different wavelengths: a home-built ultra-high resolution (UHR) OCT system at 800 nm (measured as 2.72 μm axial and 5.52 μm lateral) and a commercial OCT system at 1,300 nm with standard resolution (measured as 6.5 μm axial and 15 μm lateral), and their imaging performances were analyzed qualitatively. Using regional features derived from OCT images produced by the two systems, we developed an automated classification algorithm based on relevance vector machine (RVM) to differentiate hollow-structured adipose tissue against solid tissue. We further developed B-scan based features for RVM to classify invasive ductal carcinoma (IDC) against normal fibrous stroma tissue among OCT datasets produced by the two systems. For adipose classification, 32 UHR OCT B-scans from 9 normal specimens, and 28 standard OCT B-scans from 6 normal and 4 IDC specimens were employed. For IDC classification, 152 UHR OCT B-scans from 6 normal and 13 IDC specimens, and 104 standard OCT B-scans from 5 normal and 8 IDC specimens were employed. We have demonstrated that UHR OCT images can produce images with better feature delineation compared with images produced by 1,300 nm OCT system. UHR OCT images of a variety of tissue types found in human breast tissue were presented. With a limited number of datasets, we showed that both OCT systems can achieve a good accuracy in identifying adipose tissue. Classification in UHR OCT images achieved higher sensitivity (94%) and specificity (93%) of adipose tissue than the sensitivity (91%) and specificity (76%) in 1,300 nm OCT images. In IDC classification, similarly, we achieved better results with UHR OCT images, featured an overall accuracy of 84%, sensitivity of 89% and specificity of 71% in this preliminary study. In this study, we provided UHR OCT images of different normal and malignant breast tissue types, and qualitatively and quantitatively studied the texture and optical features from OCT images of human breast tissue at different resolutions. We developed an automated approach to differentiate adipose tissue, fibrous stroma, and IDC within human breast tissues. Our work may open the door toward automatic intraoperative OCT evaluation of early-stage breast cancer. Lasers Surg. Med. 49:258-269, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.
The Aesthetically Ideal Position of the Nipple-Areola Complex on the Breast.
Lewin, Richard; Amoroso, Matteo; Plate, Nikolina; Trogen, Clara; Selvaggi, Gennaro
2016-10-01
Several studies have attempted to identify an objective description of the aesthetically ideal breast, but they have all suffered in their reliability because of having several intrinsic limitations. It is therefore essential to design a template of ideal breast features in order to predict and evaluate aesthetic outcomes in both reconstructive and cosmetic breast surgery. The aim of this study was to determine the aesthetically preferred position of the nipple-areola complex on the breast. A questionnaire was sent by regular mail to 1000 men and 1000 women aged between 16 and 74 years. They were asked to rank the attractiveness of a series of breasts of women in images with different NAC positions. The images showed breasts from two different angles: 12 frontal-view images with both breasts shown, and five side-view images with only one breast shown. All of the breasts had equal dimensions and proportions, with the same areola size but different NAC positions. Statistical analysis of data was carried out. Eight hundred and thirteen of 2000 participants completed the questionnaire. The NAC placement preferred by both genders had a ratio of 40:60 x and 50:50 y, which means that it was best situated in the middle of the breast gland vertically and slightly lateral to the midpoint horizontally. Significant differences were found between the age and gender subgroup preferences. This study identified the preferred position of the nipple-areola complex on the female breast in the general population. This is an important information when planning breast reconstructive and cosmetic surgery. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Building an Open-source Simulation Platform of Acoustic Radiation Force-based Breast Elastography
Wang, Yu; Peng, Bo; Jiang, Jingfeng
2017-01-01
Ultrasound-based elastography including strain elastography (SE), acoustic radiation force Impulse (ARFI) imaging, point shear wave elastography (pSWE) and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published virtual simulation platform built for ultrasound quasi-static breast elastography toward acoustic radiation force-based breast elastography. Consequently, the extended virtual breast elastography simulation platform can be used to validate image pixels with known underlying soft tissue properties (i.e. “ground truth”) in complex, heterogeneous media, enhancing confidence in elastographic image interpretations. The proposed virtual breast elastography system inherited four key components from the previously published virtual simulation platform: an ultrasound simulator (Field II), a mesh generator (Tetgen), a finite element solver (FEBio) and a visualization and data processing package (VTK). Using a simple message passing mechanism, functionalities have now been extended to acoustic radiation force-based elastography simulations. Examples involving three different numerical breast models with increasing complexity – one uniform model, one simple inclusion model and one virtual complex breast model derived from magnetic resonance imaging data, were used to demonstrate capabilities of this extended virtual platform. Overall, simulation results were compared with the published results. In the uniform model, the estimated shear wave speed (SWS) values were within 4% compared to the predetermined SWS values. In the simple inclusion and the complex breast models, SWS values of all hard inclusions in soft backgrounds were slightly underestimated, similar to what has been reported. The elastic contrast values and visual observation show that ARFI images have higher spatial resolution, while SSI images can provide higher inclusion-to-background contrast. In summary, our initial results were consistent with our expectations and what have been reported in the literature. The proposed (open-source) simulation platform can serve as a single gateway to perform many elastographic simulations in a transparent manner, thereby promoting collaborative developments. PMID:28075330
Building an open-source simulation platform of acoustic radiation force-based breast elastography
NASA Astrophysics Data System (ADS)
Wang, Yu; Peng, Bo; Jiang, Jingfeng
2017-03-01
Ultrasound-based elastography including strain elastography, acoustic radiation force impulse (ARFI) imaging, point shear wave elastography and supersonic shear imaging (SSI) have been used to differentiate breast tumors among other clinical applications. The objective of this study is to extend a previously published virtual simulation platform built for ultrasound quasi-static breast elastography toward acoustic radiation force-based breast elastography. Consequently, the extended virtual breast elastography simulation platform can be used to validate image pixels with known underlying soft tissue properties (i.e. ‘ground truth’) in complex, heterogeneous media, enhancing confidence in elastographic image interpretations. The proposed virtual breast elastography system inherited four key components from the previously published virtual simulation platform: an ultrasound simulator (Field II), a mesh generator (Tetgen), a finite element solver (FEBio) and a visualization and data processing package (VTK). Using a simple message passing mechanism, functionalities have now been extended to acoustic radiation force-based elastography simulations. Examples involving three different numerical breast models with increasing complexity—one uniform model, one simple inclusion model and one virtual complex breast model derived from magnetic resonance imaging data, were used to demonstrate capabilities of this extended virtual platform. Overall, simulation results were compared with the published results. In the uniform model, the estimated shear wave speed (SWS) values were within 4% compared to the predetermined SWS values. In the simple inclusion and the complex breast models, SWS values of all hard inclusions in soft backgrounds were slightly underestimated, similar to what has been reported. The elastic contrast values and visual observation show that ARFI images have higher spatial resolution, while SSI images can provide higher inclusion-to-background contrast. In summary, our initial results were consistent with our expectations and what have been reported in the literature. The proposed (open-source) simulation platform can serve as a single gateway to perform many elastographic simulations in a transparent manner, thereby promoting collaborative developments.
... Prior Mammograms Helps Radiologists Detect Breast Cancer MammographySavesLives.org A general information resource on breast imaging from ... doctors: Breast Density and Breast Cancer Screening RTAnswers.org Radiation Therapy for Breast Cancer MedLinePlus Mammography top ...
Investigation of iterative image reconstruction in low-dose breast CT
NASA Astrophysics Data System (ADS)
Bian, Junguo; Yang, Kai; Boone, John M.; Han, Xiao; Sidky, Emil Y.; Pan, Xiaochuan
2014-06-01
There is interest in developing computed tomography (CT) dedicated to breast-cancer imaging. Because breast tissues are radiation-sensitive, the total radiation exposure in a breast-CT scan is kept low, often comparable to a typical two-view mammography exam, thus resulting in a challenging low-dose-data-reconstruction problem. In recent years, evidence has been found that suggests that iterative reconstruction may yield images of improved quality from low-dose data. In this work, based upon the constrained image total-variation minimization program and its numerical solver, i.e., the adaptive steepest descent-projection onto the convex set (ASD-POCS), we investigate and evaluate iterative image reconstructions from low-dose breast-CT data of patients, with a focus on identifying and determining key reconstruction parameters, devising surrogate utility metrics for characterizing reconstruction quality, and tailoring the program and ASD-POCS to the specific reconstruction task under consideration. The ASD-POCS reconstructions appear to outperform the corresponding clinical FDK reconstructions, in terms of subjective visualization and surrogate utility metrics.
Twellmann, Thorsten; Meyer-Baese, Anke; Lange, Oliver; Foo, Simon; Nattkemper, Tim W.
2008-01-01
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) has become an important tool in breast cancer diagnosis, but evaluation of multitemporal 3D image data holds new challenges for human observers. To aid the image analysis process, we apply supervised and unsupervised pattern recognition techniques for computing enhanced visualizations of suspicious lesions in breast MRI data. These techniques represent an important component of future sophisticated computer-aided diagnosis (CAD) systems and support the visual exploration of spatial and temporal features of DCE-MRI data stemming from patients with confirmed lesion diagnosis. By taking into account the heterogeneity of cancerous tissue, these techniques reveal signals with malignant, benign and normal kinetics. They also provide a regional subclassification of pathological breast tissue, which is the basis for pseudo-color presentations of the image data. Intelligent medical systems are expected to have substantial implications in healthcare politics by contributing to the diagnosis of indeterminate breast lesions by non-invasive imaging. PMID:19255616
Breast MRI radiogenomics: Current status and research implications.
Grimm, Lars J
2016-06-01
Breast magnetic resonance imaging (MRI) radiogenomics is an emerging area of research that has the potential to directly influence clinical practice. Clinical MRI scanners today are capable of providing excellent temporal and spatial resolution, which allows extraction of numerous imaging features via human extraction approaches or complex computer vision algorithms. Meanwhile, advances in breast cancer genetics research has resulted in the identification of promising genes associated with cancer outcomes. In addition, validated genomic signatures have been developed that allow categorization of breast cancers into distinct molecular subtypes as well as predict the risk of cancer recurrence and response to therapy. Current radiogenomics research has been directed towards exploratory analysis of individual genes, understanding tumor biology, and developing imaging surrogates to genetic analysis with the long-term goal of developing a meaningful tool for clinical care. The background of breast MRI radiogenomics research, image feature extraction techniques, approaches to radiogenomics research, and promising areas of investigation are reviewed. J. Magn. Reson. Imaging 2016;43:1269-1278. © 2015 Wiley Periodicals, Inc.
21 CFR 900.4 - Standards for accreditation bodies.
Code of Federal Regulations, 2010 CFR
2010-04-01
.... Sufficient breast tissue shall be imaged to ensure that cancers are not likely to be missed because of... potential obscuring effect of overlying breast tissue and motion artifact. (iii) Exposure level. Exposure level shall be adequate to visualize breast structures. Images shall be neither underexposed nor...
Abbreviated MRI Protocols for Detecting Breast Cancer in Women with Dense Breasts.
Chen, Shuang-Qing; Huang, Min; Shen, Yu-Ying; Liu, Chen-Lu; Xu, Chuan-Xiao
2017-01-01
To evaluate the validity of two abbreviated protocols (AP) of MRI in breast cancer screening of dense breast tissue. This was a retrospective study in 356 participants with dense breast tissue and negative mammography results. The study was approved by the Nanjing Medical University Ethics Committee. Patients were imaged with a full diagnostic protocol (FDP) of MRI. Two APs (AP-1 consisting of the first post-contrast subtracted [FAST] and maximum-intensity projection [MIP] images, and AP-2 consisting of AP-1 combined with diffusion-weighted imaging [DWI]) and FDP images were analyzed separately, and the sensitivities and specificities of breast cancer detection were calculated. Of the 356 women, 67 lesions were detected in 67 women (18.8%) by standard MR protocol, and histological examination revealed 14 malignant lesions and 53 benign lesions. The average interpretation time of AP-1 and AP-2 were 37 seconds and 54 seconds, respectively, while the average interpretation time of the FDP was 3 minutes and 25 seconds. The sensitivities of the AP-1, AP-2, and FDP were 92.9, 100, and 100%, respectively, and the specificities of the three MR protocols were 86.5, 95.0, and 96.8%, respectively. There was no significant difference among the three MR protocols in the diagnosis of breast cancer ( p > 0.05). However, the specificity of AP-1 was significantly lower than that of AP-2 ( p = 0.031) and FDP ( p = 0.035), while there was no difference between AP-2 and FDP ( p > 0.05). The AP may be efficient in the breast cancer screening of dense breast tissue. FAST and MIP images combined with DWI of MRI are helpful to improve the specificity of breast cancer detection.
The evolution of breast surgery: where technology and compassion meet.
Fine, Richard E
2004-10-01
The origins and development of The American Society of Breast Surgeons are closely tied to technology. Innovative technical progress means less-invasive procedures, more precise diagnoses, more outpatient services, and--with all of this--less pain and stress for our patients. It means more compassionate breast care for women. The Society's mission revolves around improving all aspects of patient care, and this is where technology and compassion meet.
Reducing breast biopsies by ultrasonographic analysis and a modified self-organizing map
NASA Astrophysics Data System (ADS)
Zheng, Yi; Greenleaf, James F.; Gisvold, John J.
1997-05-01
Recent studies suggest that visual evaluation of ultrasound images could decrease negative biopsies of breast cancer diagnosis. However, visual evaluation requires highly experienced breast sonographers. The objective of this study is to develop computerized radiologist assistant to reduce breast biopsies needed for evaluating suspected breast cancer. The approach of this study utilizes a neural network and tissue features extracted from digital sonographic breast images. The features include texture parameters of breast images: characteristics of echoes within and around breast lesions, and geometrical information of breast tumors. Clusters containing only benign lesions in the feature space are then identified by a modified self- organizing map. This newly developed neural network objectively segments population distributions of lesions and accurately establishes benign and equivocal regions.t eh method was applied to high quality breast sonograms of a large number of patients collected with a controlled procedure at Mayo Clinic. The study showed that the number of biopsies in this group of women could be decreased by 40 percent to 59 percent with high confidence and that no malignancies would have been included in the nonbiopsied group. The advantages of this approach are that it is robust, simple, and effective and does not require highly experienced sonographers.
Breast cancer detection in rotational thermography images using texture features
NASA Astrophysics Data System (ADS)
Francis, Sheeja V.; Sasikala, M.; Bhavani Bharathi, G.; Jaipurkar, Sandeep D.
2014-11-01
Breast cancer is a major cause of mortality in young women in the developing countries. Early diagnosis is the key to improve survival rate in cancer patients. Breast thermography is a diagnostic procedure that non-invasively images the infrared emissions from breast surface to aid in the early detection of breast cancer. Due to limitations in imaging protocol, abnormality detection by conventional breast thermography, is often a challenging task. Rotational thermography is a novel technique developed in order to overcome the limitations of conventional breast thermography. This paper evaluates this technique's potential for automatic detection of breast abnormality, from the perspective of cold challenge. Texture features are extracted in the spatial domain, from rotational thermogram series, prior to and post the application of cold challenge. These features are fed to a support vector machine for automatic classification of normal and malignant breasts, resulting in a classification accuracy of 83.3%. Feature reduction has been performed by principal component analysis. As a novel attempt, the ability of this technique to locate the abnormality has been studied. The results of the study indicate that rotational thermography holds great potential as a screening tool for breast cancer detection.
Image Processing and Computer Aided Diagnosis in Computed Tomography of the Breast
2007-03-01
TERMS breast imaging, breast CT, scatter compensation, denoising, CAD , Cone-beam CT 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF...clinical projection images. The CAD tool based on signal known exactly (SKE) scenario is under development. Task 6: Test and compare the...performances of the CAD developed in Task 5 applied to processed projection data from Task 1 with the CAD performance on the projection data without Bayesian
Breast Imaging: The Face of Imaging 3.0.
Mayo, Ray Cody; Parikh, Jay R
2016-08-01
In preparation for impending changes to the health care delivery and reimbursement models, the ACR has provided a roadmap for success via the Imaging 3.0 (®)platform. The authors illustrate how the field of breast imaging demonstrates the following Imaging 3.0 concepts: value, patient-centered care, clinical integration, structured reporting, outcome metrics, and radiology's role in the accountable care organization environment. Much of breast imaging's success may be adapted and adopted by other fields in radiology to ensure that all radiologists become more visible and provide the value sought by patients and payers. Copyright © 2016 American College of Radiology. Published by Elsevier Inc. All rights reserved.
... is removed, it is often called an excisional breast biopsy, instead of a lumpectomy. Description Sometimes, the health ... Mastectomy - discharge Surgical wound care - open Images Female breast Needle biopsy of the breast Open biopsy of the breast ...
Imaging of sound speed using reflection ultrasound tomography.
Nebeker, Jakob; Nelson, Thomas R
2012-09-01
The goal of this work was to obtain and evaluate measurements of tissue sound speed in the breast, particularly dense breasts, using backscatter ultrasound tomography. An automated volumetric breast ultrasound scanner was constructed for imaging the prone patient. A 5- to 7-MHz linear array transducer acquired 17,920 radiofrequency pulse echo A-lines from the breast, and a back-wall reflector rotated over 360° in 25 seconds. Sound speed images used reflector echoes that after preprocessing were uploaded into a graphics processing unit for filtered back-projection reconstruction. A velocimeter also was constructed to measure the sound speed and attenuation for comparison to scanner performance. Measurements were made using the following: (1) deionized water from 22°C to 90°C; (2) various fluids with sound speeds from 1240 to 1904 m/s; (3) acrylamide gel test objects with features from 1 to 15 mm in diameter; and (4) healthy volunteers. The mean error ± SD between sound speed reference and image data was -0.48% ± 9.1%, and the error between reference and velocimeter measurements was -1.78% ± 6.50%. Sound speed image and velocimeter measurements showed a difference of 0.10% ± 4.04%. Temperature data showed a difference between theory and imaging performance of -0.28% ± 0.22%. Images of polyacrylamide test objects showed detectability of an approximately 1% sound speed difference in a 2.4-mm cylindrical inclusion with a contrast to noise ratio of 7.9 dB. An automated breast scanner offers the potential to make consistent automated tomographic images of breast backscatter, sound speed, and attenuation, potentially improving diagnosis, particularly in dense breasts.
Availability of Advanced Breast Imaging at Screening Facilities Serving Vulnerable Populations.
Lee, Christoph I; Bogart, Andy; Germino, Jessica C; Goldman, L Elizabeth; Hubbard, Rebecca A; Haas, Jennifer S; Hill, Deirdre A; Tosteson, Anna Na; Alford-Teaster, Jennifer A; DeMartini, Wendy B; Lehman, Constance D; Onega, Tracy L
2016-03-01
Among vulnerable women, unequal access to advanced breast imaging modalities beyond screening mammography may lead to delays in cancer diagnosis and unfavourable outcomes. We aimed to compare on-site availability of advanced breast imaging services (ultrasound, magnetic resonance imaging [MRI], and image-guided biopsy) between imaging facilities serving vulnerable patient populations and those serving non-vulnerable populations. 73 imaging facilities across five Breast Cancer Surveillance Consortium regional registries in the United States during 2011 and 2012. We examined facility and patient characteristics across a large, national sample of imaging facilities and patients served. We characterized facilities as serving vulnerable populations based on the proportion of mammograms performed on women with lower educational attainment, lower median income, racial/ethnic minority status, and rural residence.We performed multivariable logistic regression to determine relative risks of on-site availability of advanced imaging at facilities serving vulnerable women versus facilities serving non-vulnerable women. Facilities serving vulnerable populations were as likely (Relative risk [RR] for MRI = 0.71, 95% Confidence Interval [CI] 0.42, 1.19; RR for MRI-guided biopsy = 1.07 [0.61, 1.90]; RR for stereotactic biopsy = 1.18 [0.75, 1.85]) or more likely (RR for ultrasound = 1.38 [95% CI 1.09, 1.74]; RR for ultrasound-guided biopsy = 1.67 [1.30, 2.14]) to offer advanced breast imaging services as those serving non-vulnerable populations. Advanced breast imaging services are physically available on-site for vulnerable women in the United States, but it is unknown whether factors such as insurance coverage or out-of-pocket costs might limit their use. © The Author(s) 2015.
Availability of Advanced Breast Imaging at Screening Facilities Serving Vulnerable Populations
Lee, Christoph I.; Bogart, Andy; Germino, Jessica C.; Goldman, L. Elizabeth; Hubbard, Rebecca A.; Haas, Jennifer S.; Hill, Deirdre A.; Tosteson, Anna N.A.; Alford-Teaster, Jennifer A.; DeMartini, Wendy B.; Lehman, Constance D.; Onega, Tracy L.
2015-01-01
Objective Among vulnerable women, unequal access to advanced breast imaging modalities beyond screening mammography may lead to delays in cancer diagnosis and unfavorable outcomes. We aimed to compare on-site availability of advanced breast imaging services (ultrasound (US), magnetic resonance imaging (MRI), and image-guided biopsy) between imaging facilities serving vulnerable patient populations and those serving non-vulnerable populations. Setting 73 United States imaging facilities across five Breast Cancer Surveillance Consortium regional registries during calendar years 2011–2012. Methods We examined facility and patient characteristics across a large, national sample of imaging facilities and patients served. We characterized facilities as serving vulnerable populations based on the proportion of mammograms performed on women with lower educational attainment, lower median income, racial/ethnic minority status, and rural residence. We performed multivariable logistic regression to determine relative risks of on-site availability of advanced imaging at facilities serving vulnerable women versus facilities serving non-vulnerable women. Results Facilities serving vulnerable populations were as likely (RR for MRI = 0.71 [95% CI 0.42, 1.19]; RR for MRI-guided biopsy = 1.07 [0.61, 1.90]; RR for stereotactic biopsy = 1.18 [0.75, 1.85]) or more likely (RR for US = 1.38 [95% CI 1.09, 1.74]; RR for US-guided biopsy = 1.67 [1.30, 2.14]) to offer advanced breast imaging services as those serving non-vulnerable populations. Conclusions Advanced breast imaging services are physically available on-site for vulnerable women in the United States, but it is unknown whether factors such as insurance coverage or out-of-pocket costs might limit their use. PMID:26078275
Does breast reconstruction impact the decision of patients to pursue cosmetic surgery?
Hsu, Vivian M; Tahiri, Youssef; Wes, Ari M; Yan, Chen; Selber, Jesse C; Nelson, Jonas A; Kovach, Stephen J; Serletti, Joseph M; Wu, Liza C
2014-12-01
Breast reconstruction is an integral component of breast cancer treatment, often aiding in restoring a patient's sense of femininity. However, many patients choose to have subsequent cosmetic surgery. The purpose of this study is to investigate the reasons that motivate patients to have cosmetic surgery after breast reconstruction. The authors performed a retrospective study examining patients who had breast reconstruction and subsequent cosmetic surgery at the University of Pennsylvania Health System between January 2005 and June 2012. This cohort received a questionnaire assessing the influences and impact of their reconstructive and cosmetic procedures. A total of 1,214 patients had breast reconstruction, with 113 patients (9.3%) undergoing cosmetic surgery after reconstruction. Of 42 survey respondents, 35 had autologous breast reconstruction (83.3%). Fifty-two cosmetic procedures were performed in survey respondents, including liposuction (26.9%) and facelift (15.4%). The most common reason for pursuing cosmetic surgery was the desire to improve self-image (n = 26, 61.9%), with 29 (69.0%) patients feeling more self-conscious of appearance after reconstruction. Body image satisfaction was significantly higher after cosmetic surgery (P = 0.0081). Interestingly, a multivariate analysis revealed that patients who experienced an improvement in body image after breast reconstruction were more likely to experience a further improvement after a cosmetic procedure (P = 0.031, OR = 17.83). Patients who were interested in cosmetic surgery prior to reconstruction were also more likely to experience an improvement in body image after cosmetic surgery (P = 0.012, OR = 22.63). Cosmetic surgery may improve body image satisfaction of breast reconstruction patients and help to further meet their expectations.
Effect of breast magnetic resonance imaging on the clinical management of breast cancer.
Galinsky, Daliah; Kisselgoff, David; Sella, Tamar; Peretz, Tamar; Libson, Eugene; Sklair-Levy, Miri
2005-11-01
Mammography is the principal breast cancer imaging technique; however, sensitivity is reduced, especially in dense breast tissue. Magnetic resonance imaging is increasingly used in the detection and characterization of breast cancers. The high sensitivity (95-100%) of MRI is consistently observed, and in many situations, MRI is proving superior to classical forms of imaging. Assessment of its impact on management and outcome is vital if MRI is to become standard in the management of breast cancers. To establish the impact of breast MRI on women undergoing testing in our institution. We analyzed 82 cases that underwent MRI between January 2001 and April 2003. Analysis appraised the clinical impact of MRI testing in cases where medical summaries were available. Studies were categorized into five indications: a) screening in high risk women (n=7), b) search for primary disease in the presence of disease (n=5), c) monitoring of chemotherapy (n=2), d) postoperative assessment of tumor bed (n=9), and e) diagnostic/characterization of primary or recurrent breast cancer (n=59). Results were defined as negative, positive, or no impact on clinical management. MRI testing had a positive impact in 62 cases, affecting measurable change in 9 cases. Benefit was seen in screening, diagnosis and postoperative cases. In 15 cases, MRI stimulated investigations. MRI is a valuable tool in breast imaging and affects management. Further trials are necessary to clearly define the role of MRI and to ascertain whether in cases where beneficial impact on management is noted, there is ultimate impact on outcome.
Feng, Sheng; Lotz, Thomas; Chase, J Geoffrey; Hann, Christopher E
2010-01-01
Digital Image Elasto Tomography (DIET) is a non-invasive elastographic breast cancer screening technology, based on image-based measurement of surface vibrations induced on a breast by mechanical actuation. Knowledge of frequency response characteristics of a breast prior to imaging is critical to maximize the imaging signal and diagnostic capability of the system. A feasibility analysis for a non-invasive image based modal analysis system is presented that is able to robustly and rapidly identify resonant frequencies in soft tissue. Three images per oscillation cycle are enough to capture the behavior at a given frequency. Thus, a sweep over critical frequency ranges can be performed prior to imaging to determine critical imaging settings of the DIET system to optimize its tumor detection performance.
NASA Astrophysics Data System (ADS)
Gu, Xiao-Yue; Li, Lin; Yin, Peng-Fei; Yun, Ming-Kai; Chai, Pei; Huang, Xian-Chao; Sun, Xiao-Li; Wei, Long
2015-10-01
The Positron Emission Mammography imaging system (PEMi) provides a novel nuclear diagnosis method dedicated for breast imaging. With a better resolution than whole body PET, PEMi can detect millimeter-sized breast tumors. To address the requirement of semi-quantitative analysis with a radiotracer concentration map of the breast, a new attenuation correction method based on a three-dimensional seeded region growing image segmentation (3DSRG-AC) method has been developed. The method gives a 3D connected region as the segmentation result instead of image slices. The continuity property of the segmentation result makes this new method free of activity variation of breast tissues. The threshold value chosen is the key process for the segmentation method. The first valley in the grey level histogram of the reconstruction image is set as the lower threshold, which works well in clinical application. Results show that attenuation correction for PEMi improves the image quality and the quantitative accuracy of radioactivity distribution determination. Attenuation correction also improves the probability of detecting small and early breast tumors. Supported by Knowledge Innovation Project of The Chinese Academy of Sciences (KJCX2-EW-N06)
NASA Astrophysics Data System (ADS)
Bredfeldt, Jeremy S.; Liu, Yuming; Pehlke, Carolyn A.; Conklin, Matthew W.; Szulczewski, Joseph M.; Inman, David R.; Keely, Patricia J.; Nowak, Robert D.; Mackie, Thomas R.; Eliceiri, Kevin W.
2014-01-01
Second-harmonic generation (SHG) imaging can help reveal interactions between collagen fibers and cancer cells. Quantitative analysis of SHG images of collagen fibers is challenged by the heterogeneity of collagen structures and low signal-to-noise ratio often found while imaging collagen in tissue. The role of collagen in breast cancer progression can be assessed post acquisition via enhanced computation. To facilitate this, we have implemented and evaluated four algorithms for extracting fiber information, such as number, length, and curvature, from a variety of SHG images of collagen in breast tissue. The image-processing algorithms included a Gaussian filter, SPIRAL-TV filter, Tubeness filter, and curvelet-denoising filter. Fibers are then extracted using an automated tracking algorithm called fiber extraction (FIRE). We evaluated the algorithm performance by comparing length, angle and position of the automatically extracted fibers with those of manually extracted fibers in twenty-five SHG images of breast cancer. We found that the curvelet-denoising filter followed by FIRE, a process we call CT-FIRE, outperforms the other algorithms under investigation. CT-FIRE was then successfully applied to track collagen fiber shape changes over time in an in vivo mouse model for breast cancer.
Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O’Connell, Avice M.; Conover, David L.
2013-01-01
This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of mean glandular dose to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 mGy to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9±4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4±6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum-minimum) of MGD from dedicated breast CT was lower than diagnostic mammography, the median MGD from dedicated breast CT was approximately 13.5% higher than that from diagnostic mammography. The MGD for breast CT is based on a 1.45 mm skin layer and that for diagnostic mammography is based on a 4 mm skin layer; thus, favoring a lower estimate for MGD from diagnostic mammography. The median MGD from dedicated breast CT corresponds to the median MGD from 4 to 5 diagnostic mammography views. In comparison, for the same 133 breasts, the mean and the median number of views per breast during diagnostic mammography were 4.53 and 4, respectively. Paired analysis showed that there was approximately equal likelihood of receiving lower MGD from either breast CT or diagnostic mammography. Future work will investigate methods to reduce and optimize radiation dose from dedicated breast CT. PMID:24165162
Evaluation of a novel collimator for molecular breast tomosynthesis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gilland, David R.; Welch, Benjamin L.; Lee, Seungjoon
Here, this study investigated a novel gamma camera for molecular breast tomosynthesis (MBT), which is a nuclear breast imaging method that uses limited angle tomography. The camera is equipped with a variable angle, slant-hole (VASH) collimator that allows the camera to remain close to the breast throughout the acquisition. The goal of this study was to evaluate the spatial resolution and count sensitivity of this camera and to compare contrast and contrast-to-noise ratio (CNR) with conventional planar imaging using an experimental breast phantom. Methods The VASH collimator mounts to a commercial gamma camera for breast imaging that uses a pixelatedmore » (3.2 mm), 15 × 20 cm NaI crystal. Spatial resolution was measured in planar images over a range of distances from the collimator (30-100 mm) and a range of slant angles (–25° to 25°) using 99mTc line sources. Spatial resolution was also measured in reconstructed MBT images including in the depth dimension. The images were reconstructed from data acquired over the -25° to 25° angular range using an iterative algorithm adapted to the slant-hole geometry. Sensitivity was measured over the range of slant angles using a disk source. Measured spatial resolution and sensitivity were compared to theoretical values. Contrast and CNR were measured using a breast phantom containing spherical lesions (6.2 mm and 7.8 mm diameter) and positioned over a range of depths in the phantom. The MBT and planar methods had equal scan time, and the count density in the breast phantom data was similar to that in clinical nuclear breast imaging. The MBT method used an iterative reconstruction algorithm combined with a postreconstruction Metz filter. Results The measured spatial resolution in planar images agreed well with theoretical calculations over the range of distances and slant angles. The measured FWHM was 9.7 mm at 50 mm distance. In reconstructed MBT images, the spatial resolution in the depth dimension was approximately 2.2 mm greater than the other two dimensions due to the limited angle data. The measured count sensitivity agreed closely with theory over all slant angles when using a wide energy window. At 0° slant angle, measured sensitivity was 19.7 counts sec -1 μCi -1 with the open energy window and 11.2 counts sec -1 μCi -1 with a 20% wide photopeak window (126 to 154 keV). The measured CNR in the MBT images was significantly greater than in the planar images for all but the lowest CNR cases where the lesion detectability was extremely low for both MBT and planar. The 7.8 mm lesion at 37 mm depth was marginally detectable in the planar image but easily visible in the MBT image. The improved CNR with MBT was due to a large improvement in contrast, which out-weighed the increase in image noise. Conclusion The spatial resolution and count sensitivity measurements with the prototype MBT system matched theoretical calculations, and the measured CNR in breast phantom images was generally greater with the MBT system compared to conventional planar imaging. These results demonstrate the potential of the proposed MBT system to improve lesion detection in nuclear breast imaging.« less
Evaluation of a novel collimator for molecular breast tomosynthesis.
Gilland, David R; Welch, Benjamin L; Lee, Seungjoon; Kross, Brian; Weisenberger, Andrew G
2017-11-01
This study investigated a novel gamma camera for molecular breast tomosynthesis (MBT), which is a nuclear breast imaging method that uses limited angle tomography. The camera is equipped with a variable angle, slant-hole (VASH) collimator that allows the camera to remain close to the breast throughout the acquisition. The goal of this study was to evaluate the spatial resolution and count sensitivity of this camera and to compare contrast and contrast-to-noise ratio (CNR) with conventional planar imaging using an experimental breast phantom. The VASH collimator mounts to a commercial gamma camera for breast imaging that uses a pixelated (3.2 mm), 15 × 20 cm NaI crystal. Spatial resolution was measured in planar images over a range of distances from the collimator (30-100 mm) and a range of slant angles (-25° to 25°) using 99m Tc line sources. Spatial resolution was also measured in reconstructed MBT images including in the depth dimension. The images were reconstructed from data acquired over the -25° to 25° angular range using an iterative algorithm adapted to the slant-hole geometry. Sensitivity was measured over the range of slant angles using a disk source. Measured spatial resolution and sensitivity were compared to theoretical values. Contrast and CNR were measured using a breast phantom containing spherical lesions (6.2 mm and 7.8 mm diameter) and positioned over a range of depths in the phantom. The MBT and planar methods had equal scan time, and the count density in the breast phantom data was similar to that in clinical nuclear breast imaging. The MBT method used an iterative reconstruction algorithm combined with a postreconstruction Metz filter. The measured spatial resolution in planar images agreed well with theoretical calculations over the range of distances and slant angles. The measured FWHM was 9.7 mm at 50 mm distance. In reconstructed MBT images, the spatial resolution in the depth dimension was approximately 2.2 mm greater than the other two dimensions due to the limited angle data. The measured count sensitivity agreed closely with theory over all slant angles when using a wide energy window. At 0° slant angle, measured sensitivity was 19.7 counts sec -1 μCi -1 with the open energy window and 11.2 counts sec -1 μCi -1 with a 20% wide photopeak window (126 to 154 keV). The measured CNR in the MBT images was significantly greater than in the planar images for all but the lowest CNR cases where the lesion detectability was extremely low for both MBT and planar. The 7.8 mm lesion at 37 mm depth was marginally detectable in the planar image but easily visible in the MBT image. The improved CNR with MBT was due to a large improvement in contrast, which out-weighed the increase in image noise. The spatial resolution and count sensitivity measurements with the prototype MBT system matched theoretical calculations, and the measured CNR in breast phantom images was generally greater with the MBT system compared to conventional planar imaging. These results demonstrate the potential of the proposed MBT system to improve lesion detection in nuclear breast imaging. © 2017 American Association of Physicists in Medicine.
Evaluation of a novel collimator for molecular breast tomosynthesis
Gilland, David R.; Welch, Benjamin L.; Lee, Seungjoon; ...
2017-09-06
Here, this study investigated a novel gamma camera for molecular breast tomosynthesis (MBT), which is a nuclear breast imaging method that uses limited angle tomography. The camera is equipped with a variable angle, slant-hole (VASH) collimator that allows the camera to remain close to the breast throughout the acquisition. The goal of this study was to evaluate the spatial resolution and count sensitivity of this camera and to compare contrast and contrast-to-noise ratio (CNR) with conventional planar imaging using an experimental breast phantom. Methods The VASH collimator mounts to a commercial gamma camera for breast imaging that uses a pixelatedmore » (3.2 mm), 15 × 20 cm NaI crystal. Spatial resolution was measured in planar images over a range of distances from the collimator (30-100 mm) and a range of slant angles (–25° to 25°) using 99mTc line sources. Spatial resolution was also measured in reconstructed MBT images including in the depth dimension. The images were reconstructed from data acquired over the -25° to 25° angular range using an iterative algorithm adapted to the slant-hole geometry. Sensitivity was measured over the range of slant angles using a disk source. Measured spatial resolution and sensitivity were compared to theoretical values. Contrast and CNR were measured using a breast phantom containing spherical lesions (6.2 mm and 7.8 mm diameter) and positioned over a range of depths in the phantom. The MBT and planar methods had equal scan time, and the count density in the breast phantom data was similar to that in clinical nuclear breast imaging. The MBT method used an iterative reconstruction algorithm combined with a postreconstruction Metz filter. Results The measured spatial resolution in planar images agreed well with theoretical calculations over the range of distances and slant angles. The measured FWHM was 9.7 mm at 50 mm distance. In reconstructed MBT images, the spatial resolution in the depth dimension was approximately 2.2 mm greater than the other two dimensions due to the limited angle data. The measured count sensitivity agreed closely with theory over all slant angles when using a wide energy window. At 0° slant angle, measured sensitivity was 19.7 counts sec -1 μCi -1 with the open energy window and 11.2 counts sec -1 μCi -1 with a 20% wide photopeak window (126 to 154 keV). The measured CNR in the MBT images was significantly greater than in the planar images for all but the lowest CNR cases where the lesion detectability was extremely low for both MBT and planar. The 7.8 mm lesion at 37 mm depth was marginally detectable in the planar image but easily visible in the MBT image. The improved CNR with MBT was due to a large improvement in contrast, which out-weighed the increase in image noise. Conclusion The spatial resolution and count sensitivity measurements with the prototype MBT system matched theoretical calculations, and the measured CNR in breast phantom images was generally greater with the MBT system compared to conventional planar imaging. These results demonstrate the potential of the proposed MBT system to improve lesion detection in nuclear breast imaging.« less
Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.
Makeev, Andrey; Glick, Stephen J
2017-12-01
Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.
Hand-held optical imager (Gen-2): improved instrumentation and target detectability
Gonzalez, Jean; DeCerce, Joseph; Erickson, Sarah J.; Martinez, Sergio L.; Nunez, Annie; Roman, Manuela; Traub, Barbara; Flores, Cecilia A.; Roberts, Seigbeh M.; Hernandez, Estrella; Aguirre, Wenceslao; Kiszonas, Richard
2012-01-01
Abstract. Hand-held optical imagers are developed by various researchers towards reflectance-based spectroscopic imaging of breast cancer. Recently, a Gen-1 handheld optical imager was developed with capabilities to perform two-dimensional (2-D) spectroscopic as well as three-dimensional (3-D) tomographic imaging studies. However, the imager was bulky with poor surface contact (∼30%) along curved tissues, and limited sensitivity to detect targets consistently. Herein, a Gen-2 hand-held optical imager that overcame the above limitations of the Gen-1 imager has been developed and the instrumentation described. The Gen-2 hand-held imager is less bulky, portable, and has improved surface contact (∼86%) on curved tissues. Additionally, the forked probe head design is capable of simultaneous bilateral reflectance imaging of both breast tissues, and also transillumination imaging of a single breast tissue. Experimental studies were performed on tissue phantoms to demonstrate the improved sensitivity in detecting targets using the Gen-2 imager. The improved instrumentation of the Gen-2 imager allowed detection of targets independent of their location with respect to the illumination points, unlike in Gen-1 imager. The developed imager has potential for future clinical breast imaging with enhanced sensitivity, via both reflectance and transillumination imaging. PMID:23224163
Breast density quantification with cone-beam CT: A post-mortem study
Johnson, Travis; Ding, Huanjun; Le, Huy Q.; Ducote, Justin L.; Molloi, Sabee
2014-01-01
Forty post-mortem breasts were imaged with a flat-panel based cone-beam x-ray CT system at 50 kVp. The feasibility of breast density quantification has been investigated using standard histogram thresholding and an automatic segmentation method based on the fuzzy c-means algorithm (FCM). The breasts were chemically decomposed into water, lipid, and protein immediately after image acquisition was completed. The percent fibroglandular volume (%FGV) from chemical analysis was used as the gold standard for breast density comparison. Both image-based segmentation techniques showed good precision in breast density quantification with high linear coefficients between the right and left breast of each pair. When comparing with the gold standard using %FGV from chemical analysis, Pearson’s r-values were estimated to be 0.983 and 0.968 for the FCM clustering and the histogram thresholding techniques, respectively. The standard error of the estimate (SEE) was also reduced from 3.92% to 2.45% by applying the automatic clustering technique. The results of the postmortem study suggested that breast tissue can be characterized in terms of water, lipid and protein contents with high accuracy by using chemical analysis, which offers a gold standard for breast density studies comparing different techniques. In the investigated image segmentation techniques, the FCM algorithm had high precision and accuracy in breast density quantification. In comparison to conventional histogram thresholding, it was more efficient and reduced inter-observer variation. PMID:24254317
New Technologies for Human Cancer Imaging
Frangioni, John V.
2008-01-01
Despite technical advances in many areas of diagnostic radiology, the detection and imaging of human cancer remains poor. A meaningful impact on cancer screening, staging, and treatment is unlikely to occur until the tumor-to-background ratio improves by three to four orders of magnitude (ie, 103- to 104-fold), which in turn will require proportional improvements in sensitivity and contrast agent targeting. This review analyzes the physics and chemistry of cancer imaging and highlights the fundamental principles underlying the detection of malignant cells within a background of normal cells. The use of various contrast agents and radiotracers for cancer imaging is reviewed, as are the current limitations of ultrasound, x-ray imaging, magnetic resonance imaging (MRI), single-photon emission computed tomography, positron emission tomography (PET), and optical imaging. Innovative technologies are emerging that hold great promise for patients, such as positron emission mammography of the breast and spectroscopy-enhanced colonoscopy for cancer screening, hyperpolarization MRI and time-of-flight PET for staging, and ion beam-induced PET scanning and near-infrared fluorescence-guided surgery for cancer treatment. This review explores these emerging technologies and considers their potential impact on clinical care. Finally, those cancers that are currently difficult to image and quantify, such as ovarian cancer and acute leukemia, are discussed. PMID:18711192
[Body image of women with breast cancer: a systematic review of literature].
Santos, Daniela Barsotti; Vieira, Elisabeth Meloni
2011-05-01
Women experience a major process of reshaping their body image when they deal with breast cancer. This article seeks to understand the relationship that breast cancer and its treatment have in the process of (re)construction of a woman's body image. The ultimate objective is to promote knowledge to train health professionals to become more aware of a woman's quality of life. A systematic review of the literature of scientific articles published between 2004 and 2009 available in three scientific databases was conducted and a total of 56 articles were reviewed and grouped into four thematic categories. There is a pressing need for further studies on the socio-cultural characteristics of women with breast cancer, the differences of (re)construction of body image of young and older women, and Brazilian publications about the personal experience and socio-cultural context of women with breast cancer.
Region-of-interest breast images with the Twente Photoacoustic Mammoscope (PAM)
NASA Astrophysics Data System (ADS)
Manohar, Srirang; Vaartjes, Sanne E.; van Hespen, Johan G. C.; Klaase, Joost M.; van den Engh, Frank M.; The, Andy K. H.; Steenbergen, Wiendelt; van Leeuwen, Ton G.
2007-02-01
The Twente Photoacoustic Mammoscope (PAM) is based on generating laser-induced ultrasound from absorbing structures in the breast. The heart of the instrument is a flat PVDF based detector matrix comprising 590 active elements. The exciting source is an Nd:YAG laser operating at 1064 nm with 5 ns pulses. The instrument is built around a hospital bed. A study protocol was designed to explore the feasibility of using the photoacoustic technique as embodied in PAM to detect cancer in the breasts of patients with suspect/symptomatic breasts. The protocol was approved by a Medical Ethics testing committee and the instrument approved for laser and electrical safety. The protocol was executed at the Medisch Spectrum Twente by using the mammoscope to obtain photoacoustic region-of-interest (ROI) images of the suspect/symptomatic breasts. We report on one case and compare the photoacoustic images obtained with x-ray mammograms and ultrasound images.
NASA Astrophysics Data System (ADS)
Lee, Donghoon; Kim, Ye-seul; Choi, Sunghoon; Lee, Haenghwa; Choi, Seungyeon; Kim, Hee-Joung
2016-03-01
Breast cancer is one of the most common malignancies in women. For years, mammography has been used as the gold standard for localizing breast cancer, despite its limitation in determining cancer composition. Therefore, the purpose of this simulation study is to confirm the feasibility of obtaining tumor composition using dual energy digital mammography. To generate X-ray sources for dual energy mammography, 26 kVp and 39 kVp voltages were generated for low and high energy beams, respectively. Additionally, the energy subtraction and inverse mapping functions were applied to provide compositional images. The resultant images showed that the breast composition obtained by the inverse mapping function with cubic fitting achieved the highest accuracy and least noise. Furthermore, breast density analysis with cubic fitting showed less than 10% error compare to true values. In conclusion, this study demonstrated the feasibility of creating individual compositional images and capability of analyzing breast density effectively.
[Imaging of breast tissues changes--early detection, screening and problem solving].
Wruk, Daniela
2008-04-01
In the industrialised countries breast cancer is the cancer with the highest prevalence and causes the highest rate of cancer deaths among women. In Switzerland alone, about 5000 newly diagnosed cases occur per year. Our three main diagnostic tools in imaging diseases of the breast in the setting of screening, early detection or problem solving are mammography, ultrasound and MRI with intravenous contrast application. The most important imaging technique is mammography, which as only method has shown evidence to be suitable for screening so far. As a major accomplishing imaging tool there is sonography, which in women under 30 years of age is the first method of choice in examination of the breasts. The MRI is able to provide additional information about the perfusion of tissue changes within the breast; because of its low specificity, however, it should cautiously be applied for specific questions.
Metabolic Mapping of Breast Cancer with Multiphoton Spectral and Lifetime Imaging
2008-03-01
Biomedical Optics May/June 2008 Vol. 133031220-1 the most prevalent cancer among women . 1 Therefore, tech- nologies to detect, classify, study, and...and molecular function using optical imaging: applications to breast cancer,” Breast Cancer Res. Treat. 31, 41–46 2001. 3. M. Sidani , J. Wyckoff
NASA Astrophysics Data System (ADS)
Rahman, Hameedur; Arshad, Haslina; Mahmud, Rozi; Mahayuddin, Zainal Rasyid
2017-10-01
Breast Cancer patients who require breast biopsy has increased over the past years. Augmented Reality guided core biopsy of breast has become the method of choice for researchers. However, this cancer visualization has limitations to the extent of superimposing the 3D imaging data only. In this paper, we are introducing an Augmented Reality visualization framework that enables breast cancer biopsy image guidance by using X-Ray vision technique on a mobile display. This framework consists of 4 phases where it initially acquires the image from CT/MRI and process the medical images into 3D slices, secondly it will purify these 3D grayscale slices into 3D breast tumor model using 3D modeling reconstruction technique. Further, in visualization processing this virtual 3D breast tumor model has been enhanced using X-ray vision technique to see through the skin of the phantom and the final composition of it is displayed on handheld device to optimize the accuracy of the visualization in six degree of freedom. The framework is perceived as an improved visualization experience because the Augmented Reality x-ray vision allowed direct understanding of the breast tumor beyond the visible surface and direct guidance towards accurate biopsy targets.
[Imaging of breast tumors using MR elastography].
Lorenzen, J; Sinkus, R; Schrader, D; Lorenzen, M; Leussler, C; Dargatz, M; Röschmann, P
2001-01-01
Imaging of breast tumors using MR-Elastography. Low-frequency mechanical waves are transmitted into breast-tissue by means of an oscillator. The local characteristics of the mechanical wave are determined by the elastic properties of the tissue. By means of a motion-sensitive spin-echo-sequence these waves can be displayed within the phase of the MR image. Subsequently, these images can be used to reconstruct the local distribution of elasticity. In-vivo measurements were performed in 3 female patients with malignant tumors of the breast. All patients tolerated the measurement set-up without any untoward sensation in the contact area of skin and oszillator. The waves completely penetrated the breast, encompassing the axilla and regions close to the chest wall. All tumors were localized by MRE as structures of markedly stiffer tissue when compared to the surrounding tissue. Furthermore, in one patient, a metastasis in an axillary lymph node was detected. In all patients, local regions of increased elasticity were found in the remaining parenchyma of the breast, which, however, did not reach the high levels of elasticity found in the tumors. MRE is an imaging modality enabling adjunct tissue differentiation of mammary tumors.
Gamma-ray detectors for breast imaging
NASA Astrophysics Data System (ADS)
Williams, Mark B.; Goode, Allen R.; Majewski, Stan; Steinbach, Daniela; Weisenberger, Andrew G.; Wojcik, Randolph F.; Farzanpay, Farzin
1997-07-01
Breast cancer is the most common cancer of American women and is the leading cause of cancer-related death among women aged 15 - 54; however recent years have shown that early detection using x-ray mammography can lead to a high probability of cure. However, because of mammography's low positive predictive value, surgical or core biopsy is typically required for diagnosis. In addition, the low radiographic contrast of many nonpalpable breast masses, particularly among women with radiographically dense breasts, results in an overall rate of 10% to 25% for missed tumors. Nuclear imaging of the breast using single gamma emitters (scintimammography) such as (superscript 99m)Tc, or positron emitters such as F-18- fluorodeoxyglucose (FDG) for positron emission tomography (PET), can provide information on functional or metabolic tumor activity that is complementary to the structural information of x-ray mammography, thereby potentially reducing the number of unnecessary biopsies and missed cancers. This paper summarizes recent data on the efficacy of scintimammography using conventional gamma cameras, and describes the development of dedicated detectors for gamma emission breast imaging. The detectors use new, high density crystal scintillators and large area position sensitive photomultiplier tubes (PSPMTs). Detector design, imaging requirements, and preliminary measured imaging performance are discussed.
Brozek-Pluska, Beata; Jarota, Arkadiusz; Jablonska-Gajewicz, Joanna; Kordek, Radzislaw; Czajkowski, Wojciech; Abramczyk, Halina
2012-08-01
There is a considerable interest in the developing new diagnostic techniques allowing noninvasive tracking of the progress of therapies used to treat a cancer. Raman imaging of distribution of phthalocyanine photosensitizers may open new possibilities of Photodynamic Therapy (PDT) to treat a wide range of neoplastic lesions with improved effectiveness of treatment through precise identification of malignant areas. We have employed Raman imaging and Raman spectroscopy to analyze human breast cancer tissue that interacts with photosensitizers used in the photodynamic therapy of cancer. PCA (Principal Component Analysis) has been employed to analyze various areas of the noncancerous and cancerous breast tissues. The results show that the emission spectra combined with the Raman images are very sensitive indicators to specify the aggregation state and the distribution of phthalocyanines in the cancerous and noncancerous breast tissues. Our results provide experimental evidence on the role of aggregation of phthalocyanines as a factor of particular significance in differentiation of the normal and tumourous (cancerous or benign pathology) breast tissues. We conclude that the Raman imaging reported here has a potential to be a novel and effective photodynamic therapeutic method with improved selectivity for the treatment of breast cancer.
Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography
NASA Astrophysics Data System (ADS)
Boverman, Gregory; Fang, Qianqian; Carp, Stefan A.; Miller, Eric L.; Brooks, Dana H.; Selb, Juliette; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.
2007-07-01
We develop algorithms for imaging the time-varying optical absorption within the breast given diffuse optical tomographic data collected over a time span that is long compared to the dynamics of the medium. Multispectral measurements allow for the determination of the time-varying total hemoglobin concentration and of oxygen saturation. To facilitate the image reconstruction, we decompose the hemodynamics in time into a linear combination of spatio-temporal basis functions, the coefficients of which are estimated using all of the data simultaneously, making use of a Newton-based nonlinear optimization algorithm. The solution of the extremely large least-squares problem which arises in computing the Newton update is obtained iteratively using the LSQR algorithm. A Laplacian spatial regularization operator is applied, and, in addition, we make use of temporal regularization which tends to encourage similarity between the images of the spatio-temporal coefficients. Results are shown for an extensive simulation, in which we are able to image and quantify localized changes in both total hemoglobin concentration and oxygen saturation. Finally, a breast compression study has been performed for a normal breast cancer screening subject, using an instrument which allows for highly accurate co-registration of multispectral diffuse optical measurements with an x-ray tomosynthesis image of the breast. We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast.
A physical breast phantom for 2D and 3D x-ray imaging made through inkjet printing
NASA Astrophysics Data System (ADS)
Ikejimba, Lynda C.; Graff, Christian G.; Rosenthal, Shani; Badal, Andreu; Ghammraoui, Bahaa; Lo, Joseph Y.; Glick, Stephen J.
2017-03-01
Physical breast phantoms are used for imaging evaluation studies with 2D and 3D breast x-ray systems, serving as surrogates for human patients. However, there is a presently a limited selection of available phantoms that are realistic, in terms of containing the complex tissue architecture of the human breast. In addition, not all phantoms can be successfully utilized for both 2D and 3D breast imaging. Additionally, many of the phantoms are uniform or unrealistic in appearance, expensive, or difficult to obtain. The purpose of this work was to develop a new method to generate realistic physical breast phantoms using easy to obtain and inexpensive materials. First, analytical modeling was used to design a virtual model, which was then compressed using finite element modeling. Next, the physical phantom was realized through inkjet printing with a standard inkjet printer using parchment paper and specialized inks, formulated using silver nanoparticles and a bismuth salt. The printed phantom sheets were then aligned and held together using a custom designed support plate made of PMMA, and imaged on clinical FFDM and DBT systems. Objects of interest were also placed within the phantom to simulate microcalcifications, pathologies that often occur in the breast. The linear attenuation coefficients of the inks and parchment were compared against tissue equivalent samples and found to be similar to breast tissue. The phantom is promising for use in imaging studies and developing QC protocols.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roussin, E; Archambault, L K; Wierzbicki, W
The advantages of kilovoltage cone beam CT (kV CBCT) imaging over electronic portal imaging device (EPID) such as accurate 3D anatomy, soft tissue visualization, fast rigid registration and enhanced precision on patient positioning has lead to its increasing use in clinics. The benefits of this imaging technique are at the cost of increasing the dose to healthy surrounding organs. Our center has moved toward the use of daily partial rotation kV CBCT to restrict the dose to healthy tissues. This study aims to better quantify radiation doses from different image-guidance techniques such as tangential EPID, complete and partial kV CBCTmore » for breast treatments. Cross-calibrated ionization chambers and kV calibrated Gafchromic films were used to measure the dose to the heart, lungs, breasts and skin. It was found that performing partial kV CBCT decreases the heart dose by about 36%, the lungs dose by 31%, the contralateral breast dose by 41% and the ipsilateral breast dose by 43% when compared to a full rotation CBCT. The skin dose measured for a full rotation CBCT was about 0.8 cGy for the contralateral breast and about 0.3 cGy for the ipsilateral breast. The study is still ongoing and results on skin doses for partial rotation kV CBCT as well as for tangential EPID images are upcoming.« less
N-3 Polyunsaturated Fatty Acids of Marine Origin and Multifocality in Human Breast Cancer.
Ouldamer, Lobna; Goupille, Caroline; Vildé, Anne; Arbion, Flavie; Body, Gilles; Chevalier, Stephan; Cottier, Jean Philippe; Bougnoux, Philippe
2016-01-01
The microenvironment of breast epithelial tissue may contribute to the clinical expression of breast cancer. Breast epithelial tissue, whether healthy or tumoral, is directly in contact with fat cells, which in turn could influence tumor multifocality. In this pilot study we investigated whether the fatty acid composition of breast adipose tissue differed according to breast cancer focality. Twenty-three consecutive women presenting with non-metastatic breast cancer underwent breast-imaging procedures including Magnetic Resonance Imaging prior to treatment. Breast adipose tissue specimens were collected during breast surgery. We established a biochemical profile of adipose tissue fatty acids by gas chromatography. We assessed whether there were differences according to breast cancer focality. We found that decreased levels in breast adipose tissue of docosahexaenoic and eicosapentaenoic acids, the two main polyunsaturated n-3 fatty acids of marine origin, were associated with multifocality. These differences in lipid content may contribute to mechanisms through which peritumoral adipose tissue fuels breast cancer multifocality.
Compositional breast imaging using a dual-energy mammography protocol
Laidevant, Aurelie D.; Malkov, Serghei; Flowers, Chris I.; Kerlikowske, Karla; Shepherd, John A.
2010-01-01
Purpose: Mammography has a low sensitivity in dense breasts due to low contrast between malignant and normal tissue confounded by the predominant water density of the breast. Water is found in both adipose and fibroglandular tissue and constitutes most of the mass of a breast. However, significant protein mass is mainly found in the fibroglandular tissue where most cancers originate. If the protein compartment in a mammogram could be imaged without the influence of water, the sensitivity and specificity of the mammogram may be improved. This article describes a novel approach to dual-energy mammography, full-field digital compositional mammography (FFDCM), which can independently image the three compositional components of breast tissue: water, lipid, and protein. Methods: Dual-energy attenuation and breast shape measures are used together to solve for the three compositional thicknesses. Dual-energy measurements were performed on breast-mimicking phantoms using a full-field digital mammography unit. The phantoms were made of materials shown to have similar x-ray attenuation properties of the compositional compartments. They were made of two main stacks of thicknesses around 2 and 4 cm. Twenty-six thickness and composition combinations were used to derive the compositional calibration using a least-squares fitting approach. Results: Very high accuracy was achieved with a simple cubic fitting function with root mean square errors of 0.023, 0.011, and 0.012 cm for the water, lipid, and protein thicknesses, respectively. The repeatability (percent coefficient of variation) of these measures was tested using sequential images and was found to be 0.5%, 0.5%, and 3.3% for water, lipid, and protein, respectively. However, swapping the location of the two stacks of the phantom on the imaging plate introduced further errors showing the need for more complete system uniformity corrections. Finally, a preliminary breast image is presented of each of the compositional compartments separately. Conclusions: FFDCM has been derived and exhibited good compositional thickness accuracy on phantoms. Preliminary breast images demonstrated the feasibility of creating individual compositional diagnostic images in a clinical environment. PMID:20175478
Ye, Jian; Liu, Guanghui; Liu, Peng; Zhang, Shiwu; Shao, Pengfei; Smith, Zachary J; Liu, Chenhai; Xu, Ronald X
2018-02-01
We propose a portable fluorescence microscopic imaging system (PFMS) for intraoperative display of biliary structure and prevention of iatrogenic injuries during cholecystectomy. The system consists of a light source module, a camera module, and a Raspberry Pi computer with an LCD. Indocyanine green (ICG) is used as a fluorescent contrast agent for experimental validation of the system. Fluorescence intensities of the ICG aqueous solution at different concentration levels are acquired by our PFMS and compared with those of a commercial Xenogen IVIS system. We study the fluorescence detection depth by superposing different thicknesses of chicken breast on an ICG-loaded agar phantom. We verify the technical feasibility for identifying potential iatrogenic injury in cholecystectomy using a rat model in vivo. The proposed PFMS system is portable, inexpensive, and suitable for deployment in resource-limited settings. (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).
NASA Astrophysics Data System (ADS)
Mavarani, Laven; Hillger, Philipp; Bücher, Thomas; Grzyb, Janusz; Pfeiffer, Ullrich R.; Cassar, Quentin; Al-Ibadi, Amel; Zimmer, Thomas; Guillet, Jean-Paul; Mounaix, Patrick; MacGrogan, Gaëtan
2018-03-01
Breast Cancer is one of the most frequently diagnosed cancer diseases worldwide, and the most common invasive tumour for women. As with all cancers, early detection plays a major role in reducing the mortality and morbidity rate. Currently, most breast cancers are detected due to clinical symptoms, or by screening mammography. The limitations of these techniques have resulted in research of alternative methods for imaging and detecting breast cancer. Apart from this, it is essential to define precise tumour margins during breast-conserving surgeries to reduce the re-excision rate. This study presents the advances in the development of a silicon-based THz sub-wavelength imager usable in life science applications, especially for tumour margin identification.
Segmentation of breast ultrasound images based on active contours using neutrosophic theory.
Lotfollahi, Mahsa; Gity, Masoumeh; Ye, Jing Yong; Mahlooji Far, A
2018-04-01
Ultrasound imaging is an effective approach for diagnosing breast cancer, but it is highly operator-dependent. Recent advances in computer-aided diagnosis have suggested that it can assist physicians in diagnosis. Definition of the region of interest before computer analysis is still needed. Since manual outlining of the tumor contour is tedious and time-consuming for a physician, developing an automatic segmentation method is important for clinical application. The present paper represents a novel method to segment breast ultrasound images. It utilizes a combination of region-based active contour and neutrosophic theory to overcome the natural properties of ultrasound images including speckle noise and tissue-related textures. First, due to inherent speckle noise and low contrast of these images, we have utilized a non-local means filter and fuzzy logic method for denoising and image enhancement, respectively. This paper presents an improved weighted region-scalable active contour to segment breast ultrasound images using a new feature derived from neutrosophic theory. This method has been applied to 36 breast ultrasound images. It generates true-positive and false-positive results, and similarity of 95%, 6%, and 90%, respectively. The purposed method indicates clear advantages over other conventional methods of active contour segmentation, i.e., region-scalable fitting energy and weighted region-scalable fitting energy.
2018-01-01
Molecular imaging is advantageous for screening diseases such as breast cancer by providing precise spatial information on disease-associated biomarkers, something neither blood tests nor anatomical imaging can achieve. However, the high cost and risks of ionizing radiation for several molecular imaging modalities have prevented a feasible and scalable approach for screening. Clinical studies have demonstrated the ability to detect breast tumors using nonspecific probes such as indocyanine green, but the lack of molecular information and required intravenous contrast agent does not provide a significant benefit over current noninvasive imaging techniques. Here we demonstrate that negatively charged sulfate groups, commonly used to improve solubility of near-infrared fluorophores, enable sufficient oral absorption and targeting of fluorescent molecular imaging agents for completely noninvasive detection of diseased tissue such as breast cancer. These functional groups improve the pharmacokinetic properties of affinity ligands to achieve targeting efficiencies compatible with clinical imaging devices using safe, nonionizing radiation (near-infrared light). Together, this enables development of a “disease screening pill” capable of oral absorption and systemic availability, target binding, background clearance, and imaging at clinically relevant depths for breast cancer screening. This approach should be adaptable to other molecular targets and diseases for use as a new class of screening agents. PMID:29696981
Bhatnagar, Sumit; Verma, Kirti Dhingra; Hu, Yongjun; Khera, Eshita; Priluck, Aaron; Smith, David E; Thurber, Greg M
2018-05-07
Molecular imaging is advantageous for screening diseases such as breast cancer by providing precise spatial information on disease-associated biomarkers, something neither blood tests nor anatomical imaging can achieve. However, the high cost and risks of ionizing radiation for several molecular imaging modalities have prevented a feasible and scalable approach for screening. Clinical studies have demonstrated the ability to detect breast tumors using nonspecific probes such as indocyanine green, but the lack of molecular information and required intravenous contrast agent does not provide a significant benefit over current noninvasive imaging techniques. Here we demonstrate that negatively charged sulfate groups, commonly used to improve solubility of near-infrared fluorophores, enable sufficient oral absorption and targeting of fluorescent molecular imaging agents for completely noninvasive detection of diseased tissue such as breast cancer. These functional groups improve the pharmacokinetic properties of affinity ligands to achieve targeting efficiencies compatible with clinical imaging devices using safe, nonionizing radiation (near-infrared light). Together, this enables development of a "disease screening pill" capable of oral absorption and systemic availability, target binding, background clearance, and imaging at clinically relevant depths for breast cancer screening. This approach should be adaptable to other molecular targets and diseases for use as a new class of screening agents.
Intratumoral heterogeneity as a source of discordance in breast cancer biomarker classification.
Allott, Emma H; Geradts, Joseph; Sun, Xuezheng; Cohen, Stephanie M; Zirpoli, Gary R; Khoury, Thaer; Bshara, Wiam; Chen, Mengjie; Sherman, Mark E; Palmer, Julie R; Ambrosone, Christine B; Olshan, Andrew F; Troester, Melissa A
2016-06-28
Spatial heterogeneity in biomarker expression may impact breast cancer classification. The aims of this study were to estimate the frequency of spatial heterogeneity in biomarker expression within tumors, to identify technical and biological factors contributing to spatial heterogeneity, and to examine the impact of discordant biomarker status within tumors on clinical record agreement. Tissue microarrays (TMAs) were constructed using two to four cores (1.0 mm) for each of 1085 invasive breast cancers from the Carolina Breast Cancer Study, which is part of the AMBER Consortium. Immunohistochemical staining for estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) was quantified using automated digital imaging analysis. The biomarker status for each core and for each case was assigned using clinical thresholds. Cases with core-to-core biomarker discordance were manually reviewed to distinguish intratumoral biomarker heterogeneity from misclassification of biomarker status by the automated algorithm. The impact of core-to-core biomarker discordance on case-level agreement between TMAs and the clinical record was evaluated. On the basis of automated analysis, discordant biomarker status between TMA cores occurred in 9 %, 16 %, and 18 % of cases for ER, PR, and HER2, respectively. Misclassification of benign epithelium and/or ductal carcinoma in situ as invasive carcinoma by the automated algorithm was implicated in discordance among cores. However, manual review of discordant cases confirmed spatial heterogeneity as a source of discordant biomarker status between cores in 2 %, 7 %, and 8 % of cases for ER, PR, and HER2, respectively. Overall, agreement between TMA and clinical record was high for ER (94 %), PR (89 %), and HER2 (88 %), but it was reduced in cases with core-to-core discordance (agreement 70 % for ER, 61 % for PR, and 57 % for HER2). Intratumoral biomarker heterogeneity may impact breast cancer classification accuracy, with implications for clinical management. Both manually confirmed biomarker heterogeneity and misclassification of biomarker status by automated image analysis contribute to discordant biomarker status between TMA cores. Given that manually confirmed heterogeneity is uncommon (<10 % of cases), large studies are needed to study the impact of heterogeneous biomarker expression on breast cancer classification and outcomes.
A decade of change: an institutional experience with breast surgery in 1995 and 2005.
Guth, Amber A; Shanker, Beth Ann; Roses, Daniel F; Axelrod, Deborah; Singh, Baljit; Toth, Hildegard; Shapiro, Richard L; Hiotis, Karen; Diflo, Thomas; Cangiarella, Joan F
2008-01-01
With the adoption of routine screening mammography, breast cancers are being diagnosed at earlier stages, with DCIS now accouting for 22.5% of all newly diagnosed breast cancers. This has been attributed to both increased breast cancer awareness and improvements in breast imaging techniques. How have these changes, including the increased use of image-guided sampling techniques, influenced the clinical practice of breast surgery? The institutional pathology database was queried for all breast surgeries, including breast reconstruction, performed in 1995 and 2005. Cosmetic procedures were excluded. The results were analysed utilizing the Chi-square test. Surgical indications changed during 10-year study period, with an increase in preoperatively diagnosed cancers undergoing definitive surgical management. ADH, and to a lesser extent, ALH, became indications for surgical excision. Fewer surgical biopsies were performed for indeterminate abnormalities on breast imaging, due to the introduction of stereotactic large core biopsy. While the rate of benign breast biopsies remained constant, there was a higher percentage of precancerous and DCIS cases in 2005. The overall rate of mastectomy decreased from 36.8% in 1995 to 14.5% in 2005. With the increase in sentinel node procedures, the rate of ALND dropped from 18.3% to 13.7%. Accompanying the increased recognition of early-stage cancers, the rate of positive ALND also decreased, from 43.3% to 25.0%. While the rate of benign breast biopsies has remained constant over a recent 10-year period, fewer diagnostic surgical image-guided biopsies were performed in 2005. A greater percentage of patients with breast cancer or preinvasive disease have these diagnoses determined before surgery. More preinvasive and Stage 0 cancers are undergoing surgical management. Earlier stage invasive cancers are being detected, reflected by the lower incidence of axillary nodal metastases.
A Decade of Change: An Institutional Experience with Breast Surgery in 1995 and 2005
Guth, Amber A.; Shanker, Beth Ann; Roses, Daniel F.; Axelrod, Deborah; Singh, Baljit; Toth, Hildegard; Shapiro, Richard L.; Hiotis, Karen; Diflo, Thomas; Cangiarella, Joan F.
2008-01-01
Introduction: With the adoption of routine screening mammography, breast cancers are being diagnosed at earlier stages, with DCIS now accouting for 22.5% of all newly diagnosed breast cancers. This has been attributed to both increased breast cancer awareness and improvements in breast imaging techniques. How have these changes, including the increased use of image-guided sampling techniques, influenced the clinical practice of breast surgery? Methods: The institutional pathology database was queried for all breast surgeries, including breast reconstruction, performed in 1995 and 2005. Cosmetic procedures were excluded. The results were analysed utilizing the Chi-square test. Results: Surgical indications changed during 10-year study period, with an increase in preoperatively diagnosed cancers undergoing definitive surgical management. ADH, and to a lesser extent, ALH, became indications for surgical excision. Fewer surgical biopsies were performed for indeterminate abnormalities on breast imaging, due to the introduction of stereotactic large core biopsy. While the rate of benign breast biopsies remained constant, there was a higher percentage of precancerous and DCIS cases in 2005. The overall rate of mastectomy decreased from 36.8% in 1995 to 14.5% in 2005. With the increase in sentinel node procedures, the rate of ALND dropped from 18.3% to 13.7%. Accompanying the increased recognition of early-stage cancers, the rate of positive ALND also decreased, from 43.3% to 25.0%. Conclusions: While the rate of benign breast biopsies has remained constant over a recent 10-year period, fewer diagnostic surgical image-guided biopsies were performed in 2005. A greater percentage of patients with breast cancer or preinvasive disease have these diagnoses determined before surgery. More preinvasive and Stage 0 cancers are undergoing surgical management. Earlier stage invasive cancers are being detected, reflected by the lower incidence of axillary nodal metastases. PMID:21655372
NASA Astrophysics Data System (ADS)
Dang, Jun; Frisch, Benjamin; Lasaygues, Philippe; Zhang, Dachun; Tavernier, Stefaan; Felix, Nicolas; Lecoq, Paul; Auffray, Etiennette; Varela, Joao; Mensah, Serge; Wan, Mingxi
2011-06-01
Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).
Automatic breast tissue density estimation scheme in digital mammography images
NASA Astrophysics Data System (ADS)
Menechelli, Renan C.; Pacheco, Ana Luisa V.; Schiabel, Homero
2017-03-01
Cases of breast cancer have increased substantially each year. However, radiologists are subject to subjectivity and failures of interpretation which may affect the final diagnosis in this examination. The high density features in breast tissue are important factors related to these failures. Thus, among many functions some CADx (Computer-Aided Diagnosis) schemes are classifying breasts according to the predominant density. In order to aid in such a procedure, this work attempts to describe automated software for classification and statistical information on the percentage change in breast tissue density, through analysis of sub regions (ROIs) from the whole mammography image. Once the breast is segmented, the image is divided into regions from which texture features are extracted. Then an artificial neural network MLP was used to categorize ROIs. Experienced radiologists have previously determined the ROIs density classification, which was the reference to the software evaluation. From tests results its average accuracy was 88.7% in ROIs classification, and 83.25% in the classification of the whole breast density in the 4 BI-RADS density classes - taking into account a set of 400 images. Furthermore, when considering only a simplified two classes division (high and low densities) the classifier accuracy reached 93.5%, with AUC = 0.95.
Feasibility of spatial frequency-domain imaging for monitoring palpable breast lesions
NASA Astrophysics Data System (ADS)
Robbins, Constance M.; Raghavan, Guruprasad; Antaki, James F.; Kainerstorfer, Jana M.
2017-12-01
In breast cancer diagnosis and therapy monitoring, there is a need for frequent, noninvasive disease progression evaluation. Breast tumors differ from healthy tissue in mechanical stiffness as well as optical properties, which allows optical methods to detect and monitor breast lesions noninvasively. Spatial frequency-domain imaging (SFDI) is a reflectance-based diffuse optical method that can yield two-dimensional images of absolute optical properties of tissue with an inexpensive and portable system, although depth penetration is limited. Since the absorption coefficient of breast tissue is relatively low and the tissue is quite flexible, there is an opportunity for compression of tissue to bring stiff, palpable breast lesions within the detection range of SFDI. Sixteen breast tissue-mimicking phantoms were fabricated containing stiffer, more highly absorbing tumor-mimicking inclusions of varying absorption contrast and depth. These phantoms were imaged with an SFDI system at five levels of compression. An increase in absorption contrast was observed with compression, and reliable detection of each inclusion was achieved when compression was sufficient to bring the inclusion center within ˜12 mm of the phantom surface. At highest compression level, contrasts achieved with this system were comparable to those measured with single source-detector near-infrared spectroscopy.
Towards in vivo breast skin characterization using multiphoton microscopy
NASA Astrophysics Data System (ADS)
Batista, Ana; Uchugonova, Aisada; Breunig, Hans Georg; König, Karsten
2017-02-01
Breast cancer, the most common type of cancer in women worldwide, as well as its treatment (e.g. radiation therapy) can affect the human skin. Multiphoton imaging could provide new insights into these skin alterations non-invasively and with high-resolution. As a preparation for a later investigation involving patients, areas of the breast and forearm skin of healthy volunteers were imaged using the clinically certified multiphoton imaging tomograph MPTflex based on endogenous skin autofluorescence and second-harmonic signals. Depth-resolved image stacks were acquired in consecutive weeks to explore the influence of hormonal variations on the skin properties. Both breasts were considered and up to three different areas were imaged per session. Acquisition parameters were optimized to minimize artifacts caused by breathing-motion. As a first result, skin properties, such as the epidermal thickness, appear to be influenced by hormonal variations.
2017-10-01
AWARD NUMBER: W81XWH-16-1-0524 TITLE: Non-Uniformly Sampled MR Correlated Spectroscopic Imaging in Breast Cancer and Nonlinear Reconstruction...author(s) and should not be construed as an official Department of the Army position, policy or decision unless so designated by other...COVERED 30 Sep 2016 - 29 Sep 2017 5a. CONTRACT NUMBER 4. TITLE AND SUBTITLE Non-Uniformly Sampled MR Correlated Spectroscopic Imaging in Breast
2008-08-01
AD_________________ Award Number: W81XWH-04-1-0697 TITLE: Alpha -v Integrin Targeted PET Imaging of...SUBTITLE 5a. CONTRACT NUMBER Alpha -v Integrin Targeted PET Imaging of Breast Cancer Angiogenesis and Low- Dose Metronomic Anti-Angiogenic...Evaluation of biodistribution and anti-tumor effect of a dimeric RGD peptide-paclitaxel conjugate in mice with breast cancer” was published in Eur J Nucl
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiu, T; Hrycushko, B; Zhao, B
2015-06-15
Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of watermore » container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine target volume, and is a promising image-guidance tool for prone APBI.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenfield, J.R.; La Riviere, P.J.; Sandhu, J.S.
Purpose: To characterize the dynamic response of a novel acousto-optic (AO) liquid crystal detector for high-resolution transmission ultrasound breast imaging. Transient and steady-state lesion contrast were investigated to identify optimal transducer settings for our prototype imaging system consistent with the FDA limits of 1 W/cm{sup 2} and 50 J/cm{sup 2} on the incident acoustic intensity and the transmitted acoustic energy flux density. Methods: We have developed a full-field transmission ultrasound breast imaging system that uses monochromatic plane-wave illumination to acquire projection images of the compressed breast. The acoustic intensity transmitted through the breast is converted into a visual image bymore » a proprietary liquid crystal detector operating on the basis of the AO effect. The dynamic response of the AO detector in the absence of an imaged breast was recorded by a CCD camera as a function of the acoustic field intensity and the detector exposure time. Additionally, a stereotactic needle biopsy breast phantom was used to investigate the change in opaque lesion contrast with increasing exposure time for a range of incident acoustic field intensities. Results: Using transducer voltages between 0.3 V and 0.8 V and exposure times of 3 minutes, a unique one-to-one mapping of incident acoustic intensity to steady-state optical brightness in the AO detector was observed. A transfer curve mapping acoustic intensity to steady-state optical brightness shows a high-contrast region analogous to the linear portion of the Hurter-Driffield curves of radiography. Using transducer voltages between 1 V and 1.75 V and exposure times of 90 s, the lesion contrast study demonstrated increasing lesion contrast with increasing breast exposure time and acoustic field intensity. Lesion-to-background contrast on the order of 0.80 was observed. Conclusion: Maximal lesion contrast in our prototype system can be obtained using the highest acoustic field intensity and the longest breast exposure time allowable under FDA standards. Department of Defense (DOD) Breast Cancer Research Program IDEA Award W81XWH-11-1-0332; National Institutes of Health (NIH) Grant T32 EB002103-21 from the National Institute of Biomedical Imaging and Bioengineering (NIBIB)« less
NASA Astrophysics Data System (ADS)
Tornai, Martin P.; McKinley, Randolph L.; Bryzmialkiewicz, Caryl N.; Cutler, Spencer J.; Crotty, Dominic J.
2005-04-01
With the development of several classes of dedicated emission and transmission imaging technologies utilizing ionizing radiation for improved breast cancer detection and in vivo characterization, it is extremely useful to have available anthropomorphic breast phantoms in a variety of shapes, sizes and malleability prior to clinical imaging. These anthropomorphic phantoms can be used to evaluate the implemented imaging approaches given a known quantity, the phantom, and to evaluate the variability of the measurement due to the imaging system chain. Thus, we have developed a set of fillable and incompressible breast phantoms ranging in volume from 240 to 1730mL with nipple-to-chest distances from 3.8 to 12cm. These phantoms are mountable and exchangeable on either a uniform chest plate or anthropomorphic torso phantom containing tissue equivalent bones and surface tissue. Another fillable ~700mL breast phantom with solid anterior chest plate is intentionally compressible, and can be used for direct comparisons between standard planar imaging approaches using mild-to-severe compression, partially compressed tomosynthesis, and uncompressed computed mammotomography applications. These phantoms can be filled with various fluids (water and oil based liquids) to vary the fatty tissue background composition. Shaped cellulose sponges with two cell densities are fabricated and can be added to the breasts to simulate connective tissue. Additionally, microcalcifications can be simulated by peppering slits in the sponges with oyster shell fragments. These phantoms have a utility in helping to evaluate clinical imaging paradigms with known input object parameters using basic imaging characterization, in an effort to further evaluate contemporary and next generation imaging tools. They may additionally provide a means to collect known data samples for task based optimization studies.
Validation of stereophotogrammetry of the human torso.
Lee, Juhun; Kawale, Manas; Merchant, Fatima A; Weston, June; Fingeret, Michelle C; Ladewig, Dianne; Reece, Gregory P; Crosby, Melissa A; Beahm, Elisabeth K; Markey, Mia K
2011-02-15
The objective of this study was to determine if measurements of breast morphology computed from three-dimensional (3D) stereophotogrammetry are equivalent to traditional anthropometric measurements obtained directly on a subject using a tape measure. 3D torso images of 23 women ranged in age from 36 to 63 who underwent or were scheduled for breast reconstruction surgery were obtained using a 3dMD torso system (3Q Technologies Inc., Atlanta, GA). Two different types (contoured and line-of-sight distances) of a total of nine distances were computed from 3D images of each participant. Each participant was photographed twice, first without fiducial points marked (referred to as unmarked image) and second with fiducial points marked prior to imaging (referred to as marked image). Stereophotogrammetry was compared to traditional direct anthropometry, in which measurements were taken with a tape measure on participants. Three statistical analyses were used to evaluate the agreement between stereophotogrammetry and direct anthropometry. Seven out of nine distances showed excellent agreement between stereophotogrammetry and direct anthropometry (both marked and unmarked images). In addition, stereophotogrammetry from the unmarked image was equivalent to that of the marked image (both line-of-sight and contoured distances). A lower level of agreement was observed for some measures because of difficulty in localizing more vaguely defined fiducial points, such as lowest visible point of breast mound, and inability of the imaging system in capturing areas obscured by the breast, such as the inframammary fold. Stereophotogrammetry from 3D images obtained from the 3dMD torso system is effective for quantifying breast morphology. Tools for surgical planning and evaluation based on stereophotogrammetry have the potential to improve breast surgery outcomes.
Seo, Mirinae; Jahng, Geon-Ho; Sohn, Yu-Mee; Rhee, Sun Jung; Oh, Jang-Hoon; Won, Kyu-Yeoun
2017-01-01
Objective The purpose of this study was to estimate the T2* relaxation time in breast cancer, and to evaluate the association between the T2* value with clinical-imaging-pathological features of breast cancer. Materials and Methods Between January 2011 and July 2013, 107 consecutive women with 107 breast cancers underwent multi-echo T2*-weighted imaging on a 3T clinical magnetic resonance imaging system. The Student's t test and one-way analysis of variance were used to compare the T2* values of cancer for different groups, based on the clinical-imaging-pathological features. In addition, multiple linear regression analysis was performed to find independent predictive factors associated with the T2* values. Results Of the 107 breast cancers, 92 were invasive and 15 were ductal carcinoma in situ (DCIS). The mean T2* value of invasive cancers was significantly longer than that of DCIS (p = 0.029). Signal intensity on T2-weighted imaging (T2WI) and histologic grade of invasive breast cancers showed significant correlation with T2* relaxation time in univariate and multivariate analysis. Breast cancer groups with higher signal intensity on T2WI showed longer T2* relaxation time (p = 0.005). Cancer groups with higher histologic grade showed longer T2* relaxation time (p = 0.017). Conclusion The T2* value is significantly longer in invasive cancer than in DCIS. In invasive cancers, T2* relaxation time is significantly longer in higher histologic grades and high signal intensity on T2WI. Based on these preliminary data, quantitative T2* mapping has the potential to be useful in the characterization of breast cancer. PMID:28096732
[Management of breast nipple discharge: Recommendations].
Ouldamer, L; Kellal, I; Legendre, G; Ngô, C; Chopier, J; Body, G
2015-12-01
To investigate diagnostic value of imaging procedures and management strategies of the patients with nipple discharge (ND) to establish management recommendations. Bibliographical search in French and English languages by consultation of PubMed, Cochrane and Embase databases. Although, all ND require an systematic evaluation guided by clinical data, bloody ND could be a predictor of breast cancer risk among different colors of discharge particularly in patients of more than 50 years (LE2). The mammography and breast ultrasography are the imaging procedures to realize in first intention (grade C) but they turn out useful only when they detect radiological abnormalities (LE4). Galactography has only a localizing value of possible ductal abnormalities (when standard imaging procedures is not contributive) (LE4). Thus, in the diagnostic investigation of a suspicious ND, galactography it is not recommended in standard practice (grade C). The breast Magnetic Resonance Imaging (MRI) is recommended when breast standard imaging procedures are not contributive (grade C). The ND cytology is useful only if it is positive (i.e. reveal cancer cells). There is no proof on the diagnostic performance of the cytological analysis of the ND to allow a recommendation on its realization or not. In front of a suspicious ND, when breast-imaging procedures reveals an associated radiological lesion, an adapted percutaneous biopsy is recommended by percutaneous way (grade C). Vacuum-assisted breast biopsies is a diagnostic tool but can also be therapeutic allowing to avoid surgery in case of benign lesion but current literature data do not allow recommendations on the therapeutic aspect of vacuum-assisted breast biopsy (LE4). In the absence of associated radiological signal, and in case of reproducible bloody persistent ND, a pyramidectomy is recommended (grade C). Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Rella, Rossella; Belli, Paolo; Giuliani, Michela; Bufi, Enida; Carlino, Giorgio; Rinaldi, Pierluigi; Manfredi, Riccardo
2018-03-16
Automated breast ultrasonography (ABUS) is a new imaging technology for automatic breast scanning through ultrasound. It was first developed to overcome the limitation of operator dependency and lack of standardization and reproducibility of handheld ultrasound. ABUS provides a three-dimensional representation of breast tissue and allows images reformatting in three planes, and the generated coronal plane has been suggested to improve diagnostic accuracy. This technique has been first used in the screening setting to improve breast cancer detection, especially in mammographically dense breasts. In recent years, numerous studies also evaluated its use in the diagnostic setting: they showed its suitability for breast cancer staging, evaluation of tumor response to neoadjuvant chemotherapy, and second-look ultrasound after magnetic resonance imaging. The purpose of this article is to provide a comprehensive review of the current body of literature about the clinical performance of ABUS, summarize available evidence, and identify gaps in knowledge for future research. Copyright © 2018 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Inverse scattering and refraction corrected reflection for breast cancer imaging
NASA Astrophysics Data System (ADS)
Wiskin, J.; Borup, D.; Johnson, S.; Berggren, M.; Robinson, D.; Smith, J.; Chen, J.; Parisky, Y.; Klock, John
2010-03-01
Reflection ultrasound (US) has been utilized as an adjunct imaging modality for over 30 years. TechniScan, Inc. has developed unique, transmission and concomitant reflection algorithms which are used to reconstruct images from data gathered during a tomographic breast scanning process called Warm Bath Ultrasound (WBU™). The transmission algorithm yields high resolution, 3D, attenuation and speed of sound (SOS) images. The reflection algorithm is based on canonical ray tracing utilizing refraction correction via the SOS and attenuation reconstructions. The refraction correction reflection algorithm allows 360 degree compounding resulting in the reflection image. The requisite data are collected when scanning the entire breast in a 33° C water bath, on average in 8 minutes. This presentation explains how the data are collected and processed by the 3D transmission and reflection imaging mode algorithms. The processing is carried out using two NVIDIA® Tesla™ GPU processors, accessing data on a 4-TeraByte RAID. The WBU™ images are displayed in a DICOM viewer that allows registration of all three modalities. Several representative cases are presented to demonstrate potential diagnostic capability including: a cyst, fibroadenoma, and a carcinoma. WBU™ images (SOS, attenuation, and reflection modalities) are shown along with their respective mammograms and standard ultrasound images. In addition, anatomical studies are shown comparing WBU™ images and MRI images of a cadaver breast. This innovative technology is designed to provide additional tools in the armamentarium for diagnosis of breast disease.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Libby, B.
2015-06-15
Is Non-invasive Image-Guided Breast Brachytherapy Good? – Jess Hiatt, MS Non-invasive Image-Guided Breast Brachytherapy (NIBB) is an emerging therapy for breast boost treatments as well as Accelerated Partial Breast Irradiation (APBI) using HDR surface breast brachytherapy. NIBB allows for smaller treatment volumes while maintaining optimal target coverage. Considering the real-time image-guidance and immobilization provided by the NIBB modality, minimal margins around the target tissue are necessary. Accelerated Partial Breast Irradiation in brachytherapy: is shorter better? - Dorin Todor, PhD VCU A review of balloon and strut devices will be provided together with the origins of APBI: the interstitial multi-catheter implant.more » A dosimetric and radiobiological perspective will help point out the evolution in breast brachytherapy, both in terms of devices and the protocols/clinical trials under which these devices are used. Improvements in imaging, delivery modalities and convenience are among the factors driving the ultrashort fractionation schedules but our understanding of both local control and toxicities associated with various treatments is lagging. A comparison between various schedules, from a radiobiological perspective, will be given together with a critical analysis of the issues. to review and understand the evolution and development of APBI using brachytherapy methods to understand the basis and limitations of radio-biological ‘equivalence’ between fractionation schedules to review commonly used and proposed fractionation schedules Intra-operative breast brachytherapy: Is one stop shopping best?- Bruce Libby, PhD. University of Virginia A review of intraoperative breast brachytherapy will be presented, including the Targit-A and other trials that have used electronic brachytherapy. More modern approaches, in which the lumpectomy procedure is integrated into an APBI workflow, will also be discussed. Learning Objectives: To review past and current clinical trials for IORT To discuss lumpectomy-scan-plan-treat workflow for IORT.« less
Park, Vivian Youngjean; Kim, Eun-Kyung; Kim, Min Jung; Moon, Hee Jung; Yoon, Jung Hyun
2018-01-22
Women with a personal history of breast cancer are at increased risk of future breast cancer events, and may benefit from supplemental screening methods that could enhance early detection of subclinical disease. However, current literature on breast magnetic resonance (MR) imaging surveillance is limited. We investigated outcomes of surveillance breast magnetic resonance (MR) imaging in women with a personal history of breast cancer. We reviewed 1053 consecutive breast MR examinations that were performed for surveillance in 1044 women (median age, 53 years; range, 20-85 years) previously treated for breast cancer between August 2014 and February 2016. All patients had previously received supplemental surveillance with ultrasound. Cancer detection rate (CDR), abnormal interpretation rate and characteristics of MR-detected cancers were assessed, including extramammary cancers. We also calculated the PPV 1 , PPV 3 , sensitivity and specificity for MR-detected intramammary lesions. Performance statistics were stratified by interval following initial surgery. The CDR for MR-detected cancers was 6.7 per 1000 examinations (7 of 1053) and was 3.8 per 1000 examinations (4 of 1053) for intramammary cancers. The overall abnormal interpretation rate was 8.0%, and the abnormal interpretation rate for intramammary lesions was 7.2%. The PPV 1 , PPV 3 , sensitivity and specificity for intramammary lesions was 5.3% (4 of 76), 15.8% (3 of 19), 75.0% (3 of 4) and 98.3% (1031 of 1049), respectively. For MR examinations performed ≤36 months after surgery, the overall CDR was 1.4 per 1000 examinations. For MR examinations performed > 36 months after surgery, the overall CDR was 17.4 per 1000 examinations. Surveillance breast MR imaging may be considered in women with a history of breast cancer, considering the low abnormal interpretation rate and its high specificity. However, the cancer detection rate was low and implementation may be more effective after more than 3 years after surgery.
Occult Primary Neuroendocrine Tumor Metastasis to the Breast Detected on Screening Mammogram.
Policeni, Fabiana; Pakalniskis, Brittany; Yang, Limin
2016-01-01
Metastatic tumors are rare in the breast. Well-differentiated neuroendocrine tumors (WDNETs) are slow-growing neoplasms that arise from neuroendocrine cells, particularly in the gastrointestinal tract and bronchial tree. Metastatic WDNET to the breast is a rare entity. We present a case report of ileal WDNET metastatic to the breast which was initially identified as a small mass in the patient's left breast on screening mammography. Targeted ultrasound identified a suspicious mass, and ultrasound-guided percutaneous core biopsy was performed. Pathology revealed metastatic WDNET. Breast magnetic resonance imaging (MRI) was then performed and demonstrated left axillary Level 2 lymphadenopathy, and liver lesions were suspicious for metastasis. The patient underwent abdominal computed tomography (CT) to evaluate for distant metastatic disease. A spiculated mass was found near the ileocecal valve, suggestive of primary ileal WDNET. In addition, CT identified multiple liver lesions, most compatible with metastasis. Indium 111 OctreoScan confirmed radiotracer uptake in the ileum consistent with primary neuroendocrine tumor. In this report, we review the imaging characteristics of metastatic WDNET to the breast by different imaging modalities including mammogram, ultrasound, and breast MRI.
Optimal exposure techniques for iodinated contrast enhanced breast CT
NASA Astrophysics Data System (ADS)
Glick, Stephen J.; Makeev, Andrey
2016-03-01
Screening for breast cancer using mammography has been very successful in the effort to reduce breast cancer mortality, and its use has largely resulted in the 30% reduction in breast cancer mortality observed since 1990 [1]. However, diagnostic mammography remains an area of breast imaging that is in great need for improvement. One imaging modality proposed for improving the accuracy of diagnostic workup is iodinated contrast-enhanced breast CT [2]. In this study, a mathematical framework is used to evaluate optimal exposure techniques for contrast-enhanced breast CT. The ideal observer signal-to-noise ratio (i.e., d') figure-of-merit is used to provide a task performance based assessment of optimal acquisition parameters under the assumptions of a linear, shift-invariant imaging system. A parallel-cascade model was used to estimate signal and noise propagation through the detector, and a realistic lesion model with iodine uptake was embedded into a structured breast background. Ideal observer performance was investigated across kVp settings, filter materials, and filter thickness. Results indicated many kVp spectra/filter combinations can improve performance over currently used x-ray spectra.
Grid-Enabled Quantitative Analysis of Breast Cancer
2010-10-01
large-scale, multi-modality computerized image analysis . The central hypothesis of this research is that large-scale image analysis for breast cancer...research, we designed a pilot study utilizing large scale parallel Grid computing harnessing nationwide infrastructure for medical image analysis . Also
2006-03-01
Evaluation of fully 3D emission mammotomography with a compact cadmium zinc telluride detector,” IEEE Trans. Med. Imag. (Submitted) 2005. [16] M.P...times over a few months, and the degradation due to compromised adipose tissue boundaries as well as other physical breast features are becoming...breast lesions, especially in radiographically dense breasts,2,11-13 through the removal of contrast-reducing overlying tissue ; (2) uncompressed
Body image issues in women with breast cancer.
Helms, Rebecca L; O'Hea, Erin L; Corso, Marlaena
2008-05-01
Diagnosis and treatment of breast cancer affects women physically as well as psychologically. There are many obvious and real factors that are related to psychological distress in women coping with breast cancer, such as facing a life-threatening illness, painful and impairing treatments, and significant role changes. Although these factors are clearly important, issues related to body image in women faced with breast cancer can also add to psychological distress. Women, in general, are concerned with their appearance, their weight, and their body, with recent studies suggesting 89% of women reported concerns with weight. Such premorbid concerns are often deeply ingrained and can contribute to psychological distress in women treated for breast cancer. The present article is a summary of the literature that has examined body image issues and related psychological adjustment in women with breast cancer. Implications for clinical practice and recommendations for future investigations are discussed.
Digital optical tomography system for dynamic breast imaging
NASA Astrophysics Data System (ADS)
Flexman, Molly L.; Khalil, Michael A.; Al Abdi, Rabah; Kim, Hyun K.; Fong, Christopher J.; Desperito, Elise; Hershman, Dawn L.; Barbour, Randall L.; Hielscher, Andreas H.
2011-07-01
Diffuse optical tomography has shown promising results as a tool for breast cancer screening and monitoring response to chemotherapy. Dynamic imaging of the transient response of the breast to an external stimulus, such as pressure or a respiratory maneuver, can provide additional information that can be used to detect tumors. We present a new digital continuous-wave optical tomography system designed to simultaneously image both breasts at fast frame rates and with a large number of sources and detectors. The system uses a master-slave digital signal processor-based detection architecture to achieve a dynamic range of 160 dB and a frame rate of 1.7 Hz with 32 sources, 64 detectors, and 4 wavelengths per breast. Included is a preliminary study of one healthy patient and two breast cancer patients showing the ability to identify an invasive carcinoma based on the hemodynamic response to a breath hold.
Samah, Asnarulkhadi Abu; Ahmadian, Maryam
2014-01-01
This study aimed to examine the relationship between body image satisfaction and breast self-screening behavior and intentions. The sample for this cross-sectional study consisted of 842 female university students who were recruited from a number of public and private universities. Data were obtained between the months of November and December, 2013, using multistage random cluster sampling. Main research variables were breast cancer screening behavior and intentions, demographic factors, and the total scores on each of the Multidimensional Body-Self Relations Questionnaire (MBSRQ-Appearance Scales) subscales. Results of multivariate analysis showed that having higher satisfaction and more positive evaluation of appearance were related to having performed breast self-examination more frequently in the last year and intending to perform breast self-examination more frequently in the next year. Longitudinal research can potentially provide detailed information about overall body image satisfaction and breast cancer screening behavior among various communities.
Medical imaging and computers in the diagnosis of breast cancer
NASA Astrophysics Data System (ADS)
Giger, Maryellen L.
2014-09-01
Computer-aided diagnosis (CAD) and quantitative image analysis (QIA) methods (i.e., computerized methods of analyzing digital breast images: mammograms, ultrasound, and magnetic resonance images) can yield novel image-based tumor and parenchyma characteristics (i.e., signatures that may ultimately contribute to the design of patient-specific breast cancer management plans). The role of QIA/CAD has been expanding beyond screening programs towards applications in risk assessment, diagnosis, prognosis, and response to therapy as well as in data mining to discover relationships of image-based lesion characteristics with genomics and other phenotypes; thus, as they apply to disease states. These various computer-based applications are demonstrated through research examples from the Giger Lab.
Development of a fully automatic scheme for detection of masses in whole breast ultrasound images.
Ikedo, Yuji; Fukuoka, Daisuke; Hara, Takeshi; Fujita, Hiroshi; Takada, Etsuo; Endo, Tokiko; Morita, Takako
2007-11-01
Ultrasonography has been used for breast cancer screening in Japan. Screening using a conventional hand-held probe is operator dependent and thus it is possible that some areas of the breast may not be scanned. To overcome such problems, a mechanical whole breast ultrasound (US) scanner has been proposed and developed for screening purposes. However, another issue is that radiologists might tire while interpreting all images in a large-volume screening; this increases the likelihood that masses may remain undetected. Therefore, the aim of this study is to develop a fully automatic scheme for the detection of masses in whole breast US images in order to assist the interpretations of radiologists and potentially improve the screening accuracy. The authors database comprised 109 whole breast US imagoes, which include 36 masses (16 malignant masses, 5 fibroadenomas, and 15 cysts). A whole breast US image with 84 slice images (interval between two slice images: 2 mm) was obtained by the ASU-1004 US scanner (ALOKA Co., Ltd., Japan). The feature based on the edge directions in each slice and a method for subtracting between the slice images were used for the detection of masses in the authors proposed scheme. The Canny edge detector was applied to detect edges in US images; these edges were classified as near-vertical edges or near-horizontal edges using a morphological method. The positions of mass candidates were located using the near-vertical edges as a cue. Then, the located positions were segmented by the watershed algorithm and mass candidate regions were detected using the segmented regions and the low-density regions extracted by the slice subtraction method. For the removal of false positives (FPs), rule-based schemes and a quadratic discriminant analysis were applied for the distribution between masses and FPs. As a result, the sensitivity of the authors scheme for the detection of masses was 80.6% (29/36) with 3.8 FPs per whole breast image. The authors scheme for a computer-aided detection may be useful in improving the screening performance and efficiency.
Breast Cancer Screening, Mammography, and Other Modalities.
Fiorica, James V
2016-12-01
This article is an overview of the modalities available for breast cancer screening. The modalities discussed include digital mammography, digital breast tomosynthesis, breast ultrasonography, magnetic resonance imaging, and clinical breast examination. There is a review of pertinent randomized controlled trials, studies and meta-analyses which contributed to the evolution of screening guidelines. Ultimately, 5 major medical organizations formulated the current screening guidelines in the United States. The lack of consensus in these guidelines represents an ongoing controversy about the optimal timing and method for breast cancer screening in women. For mammography screening, the Breast Imaging Reporting and Data System lexicon is explained which corresponds with recommended clinical management. The presentation and discussion of the data in this article are designed to help the clinician individualize breast cancer screening for each patient.
Keller, Brad M; Nathan, Diane L; Gavenonis, Sara C; Chen, Jinbo; Conant, Emily F; Kontos, Despina
2013-05-01
Mammographic breast density, a strong risk factor for breast cancer, may be measured as either a relative percentage of dense (ie, radiopaque) breast tissue or as an absolute area from either raw (ie, "for processing") or vendor postprocessed (ie, "for presentation") digital mammograms. Given the increasing interest in the incorporation of mammographic density in breast cancer risk assessment, the purpose of this study is to determine the inherent reader variability in breast density assessment from raw and vendor-processed digital mammograms, because inconsistent estimates could to lead to misclassification of an individual woman's risk for breast cancer. Bilateral, mediolateral-oblique view, raw, and processed digital mammograms of 81 women were retrospectively collected for this study (N = 324 images). Mammographic percent density and absolute dense tissue area estimates for each image were obtained from two radiologists using a validated, interactive software tool. The variability of interreader agreement was not found to be affected by the image presentation style (ie, raw or processed, F-test: P > .5). Interreader estimates of relative and absolute breast density are strongly correlated (Pearson r > 0.84, P < .001) but systematically different (t-test, P < .001) between the two readers. Our results show that mammographic density may be assessed with equal reliability from either raw or vendor postprocessed images. Furthermore, our results suggest that the primary source of density variability comes from the subjectivity of the individual reader in assessing the absolute amount of dense tissue present in the breast, indicating the need to use standardized tools to mitigate this effect. Copyright © 2013 AUR. Published by Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Zhou, Xiangrong; Kano, Takuya; Koyasu, Hiromi; Li, Shuo; Zhou, Xinxin; Hara, Takeshi; Matsuo, Masayuki; Fujita, Hiroshi
2017-03-01
This paper describes a novel approach for the automatic assessment of breast density in non-contrast three-dimensional computed tomography (3D CT) images. The proposed approach trains and uses a deep convolutional neural network (CNN) from scratch to classify breast tissue density directly from CT images without segmenting the anatomical structures, which creates a bottleneck in conventional approaches. Our scheme determines breast density in a 3D breast region by decomposing the 3D region into several radial 2D-sections from the nipple, and measuring the distribution of breast tissue densities on each 2D section from different orientations. The whole scheme is designed as a compact network without the need for post-processing and provides high robustness and computational efficiency in clinical settings. We applied this scheme to a dataset of 463 non-contrast CT scans obtained from 30- to 45-year-old-women in Japan. The density of breast tissue in each CT scan was assigned to one of four categories (glandular tissue within the breast <25%, 25%-50%, 50%-75%, and >75%) by a radiologist as ground truth. We used 405 CT scans for training a deep CNN and the remaining 58 CT scans for testing the performance. The experimental results demonstrated that the findings of the proposed approach and those of the radiologist were the same in 72% of the CT scans among the training samples and 76% among the testing samples. These results demonstrate the potential use of deep CNN for assessing breast tissue density in non-contrast 3D CT images.
Tummers, Quirijn R.J.G.; Verbeek, Floris P.R.; Schaafsma, Boudewijn E.; Boonstra, Martin C.; van der Vorst, Joost R.; Liefers, Gerrit-Jan; van de Velde, Cornelis J.H.; Frangioni, John V.; Vahrmeijer, Alexander L.
2014-01-01
Background Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast-conserving surgery. Based on certain physicochemical similarities between Technetium(99mTc)-sestamibi (MIBI), a SPECT radiodiagnostic with a sensitivity of 83–90% to detect breast cancer preoperatively, and the near-infrared (NIR) fluorophore Methylene Blue (MB), we hypothesized that MB might detect breast cancer intraoperatively using NIR fluorescence imaging. Methods Twenty-four patients with breast cancer, planned for surgical resection, were included. Patients were divided in 2 administration groups, which differed with respect to the timing of MB administration. N = 12 patients per group were administered 1.0 mg/kg MB intravenously either immediately or 3 h before surgery. The mini-FLARE imaging system was used to identify the NIR fluorescent signal during surgery and on post-resected specimens transferred to the pathology department. Results were confirmed by NIR fluorescence microscopy. Results 20/24 (83%) of breast tumors (carcinoma in N=21 and ductal carcinoma in situ in N=3) were identified in the resected specimen using NIR fluorescence imaging. Patients with non-detectable tumors were significantly older. No significant relation to receptor status or tumor grade was seen. Overall tumor-to-background ratio (TBR) was 2.4 ± 0.8. There was no significant difference between TBR and background signal between administration groups. In 2/4 patients with positive resection margins, breast cancer tissue identified in the wound bed during surgery would have changed surgical management. Histology confirmed the concordance of fluorescence signal and tumor tissue. Conclusions This feasibility study demonstrated an overall breast cancer identification rate using MB of 83%, with real-time intraoperative guidance having the potential to alter patient management. PMID:24862545
Tummers, Q R J G; Verbeek, F P R; Schaafsma, B E; Boonstra, M C; van der Vorst, J R; Liefers, G-J; van de Velde, C J H; Frangioni, J V; Vahrmeijer, A L
2014-07-01
Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast conserving surgery. Based on certain physicochemical similarities between Technetium((99m)Tc)-sestamibi (MIBI), an SPECT radiodiagnostic with a sensitivity of 83-90% to detect breast cancer preoperatively, and the near-infrared (NIR) fluorophore Methylene Blue (MB), we hypothesized that MB might detect breast cancer intraoperatively using NIR fluorescence imaging. Twenty-four patients with breast cancer, planned for surgical resection, were included. Patients were divided in 2 administration groups, which differed with respect to the timing of MB administration. N = 12 patients per group were administered 1.0 mg/kg MB intravenously either immediately or 3 h before surgery. The mini-FLARE imaging system was used to identify the NIR fluorescent signal during surgery and on post-resected specimens transferred to the pathology department. Results were confirmed by NIR fluorescence microscopy. 20/24 (83%) of breast tumors (carcinoma in N = 21 and ductal carcinoma in situ in N = 3) were identified in the resected specimen using NIR fluorescence imaging. Patients with non-detectable tumors were significantly older. No significant relation to receptor status or tumor grade was seen. Overall tumor-to-background ratio (TBR) was 2.4 ± 0.8. There was no significant difference between TBR and background signal between administration groups. In 2/4 patients with positive resection margins, breast cancer tissue identified in the wound bed during surgery would have changed surgical management. Histology confirmed the concordance of fluorescence signal and tumor tissue. This feasibility study demonstrated an overall breast cancer identification rate using MB of 83%, with real-time intraoperative guidance having the potential to alter patient management. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Ahn, Chul Kyun; Heo, Changyong; Jin, Heongmin; Kim, Jong Hyo
2017-03-01
Mammographic breast density is a well-established marker for breast cancer risk. However, accurate measurement of dense tissue is a difficult task due to faint contrast and significant variations in background fatty tissue. This study presents a novel method for automated mammographic density estimation based on Convolutional Neural Network (CNN). A total of 397 full-field digital mammograms were selected from Seoul National University Hospital. Among them, 297 mammograms were randomly selected as a training set and the rest 100 mammograms were used for a test set. We designed a CNN architecture suitable to learn the imaging characteristic from a multitudes of sub-images and classify them into dense and fatty tissues. To train the CNN, not only local statistics but also global statistics extracted from an image set were used. The image set was composed of original mammogram and eigen-image which was able to capture the X-ray characteristics in despite of the fact that CNN is well known to effectively extract features on original image. The 100 test images which was not used in training the CNN was used to validate the performance. The correlation coefficient between the breast estimates by the CNN and those by the expert's manual measurement was 0.96. Our study demonstrated the feasibility of incorporating the deep learning technology into radiology practice, especially for breast density estimation. The proposed method has a potential to be used as an automated and quantitative assessment tool for mammographic breast density in routine practice.
Assessing the future of diffuse optical imaging technologies for breast cancer management
Tromberg, Bruce J.; Pogue, Brian W.; Paulsen, Keith D.; Yodh, Arjun G.; Boas, David A.; Cerussi, Albert E.
2008-01-01
Diffuse optical imaging (DOI) is a noninvasive optical technique that employs near-infrared (NIR) light to quantitatively characterize the optical properties of thick tissues. Although NIR methods were first applied to breast transillumination (also called diaphanography) nearly 80 years ago, quantitative DOI methods employing time- or frequency-domain photon migration technologies have only recently been used for breast imaging (i.e., since the mid-1990s). In this review, the state of the art in DOI for breast cancer is outlined and a multi-institutional Network for Translational Research in Optical Imaging (NTROI) is described, which has been formed by the National Cancer Institute to advance diffuse optical spectroscopy and imaging (DOSI) for the purpose of improving breast cancer detection and clinical management. DOSI employs broadband technology both in near-infrared spectral and temporal signal domains in order to separate absorption from scattering and quantify uptake of multiple molecular probes based on absorption or fluorescence contrast. Additional dimensionality in the data is provided by integrating and co-registering the functional information of DOSI with x-ray mammography and magnetic resonance imaging (MRI), which provide structural information or vascular flow information, respectively. Factors affecting DOSI performance, such as intrinsic and extrinsic contrast mechanisms, quantitation of biochemical components, image formation∕visualization, and multimodality co-registration are under investigation in the ongoing research NTROI sites. One of the goals is to develop standardized DOSI platforms that can be used as stand-alone devices or in conjunction with MRI, mammography, or ultrasound. This broad-based, multidisciplinary effort is expected to provide new insight regarding the origins of breast disease and practical approaches for addressing several key challenges in breast cancer, including: Detecting disease in mammographically dense tissue, distinguishing between malignant and benign lesions, and understanding the impact of neoadjuvant chemotherapies. PMID:18649477
Computerized analysis of sonograms for the detection of breast lesions
NASA Astrophysics Data System (ADS)
Drukker, Karen; Giger, Maryellen L.; Horsch, Karla; Vyborny, Carl J.
2002-05-01
With a renewed interest in using non-ionizing radiation for the screening of high risk women, there is a clear role for a computerized detection aid in ultrasound. Thus, we are developing a computerized detection method for the localization of lesions on breast ultrasound images. The computerized detection scheme utilizes two methods. Firstly, a radial gradient index analysis is used to distinguish potential lesions from normal parenchyma. Secondly, an image skewness analysis is performed to identify posterior acoustic shadowing. We analyzed 400 cases (757 images) consisting of complex cysts, solid benign lesions, and malignant lesions. The detection method yielded an overall sensitivity of 95% by image, and 99% by case at a false-positive rate of 0.94 per image. In 51% of all images, only the lesion itself was detected, while in 5% of the images only the shadowing was identified. For malignant lesions these numbers were 37% and 9%, respectively. In summary, we have developed a computer detection method for lesions on ultrasound images of the breast, which may ultimately aid in breast cancer screening.
Breast imaging with ultrasound tomography: update on a comparative study with MR
NASA Astrophysics Data System (ADS)
Ranger, Bryan; Littrup, Peter; Duric, Neb; Li, Cuiping; Schmidt, Steven; Rama, Olsi; Bey-Knight, Lisa
2011-03-01
The objective of this study is to present imaging parameters and display thresholds of an ultrasound tomography (UST) prototype in order to demonstrate analogous visualization of overall breast anatomy and lesions relative to magnetic resonance (MR). Thirty-six women were imaged with MR and our UST prototype. The UST scan generated sound speed, attenuation, and reflection images and were subjected to variable thresholds then fused together into a single UST image. Qualitative and quantitative comparisons of MR and UST images were utilized to identify anatomical similarities and mass characteristics. Overall, UST demonstrated the ability to visualize and characterize breast tissues in a manner comparable to MR without the use of IV contrast. For optimal visualization, fused images utilized thresholds of 1.46+/-0.1 km/s for sound speed to represent architectural features of the breast including parenchyma. An arithmetic combination of images using the logical .AND. and .OR. operators, along with thresholds of 1.52+/-0.03 km/s for sound speed and 0.16+/-0.04 dB/cm for attenuation, allowed for mass detection and characterization similar to MR.
Relationship between breast sound speed and mammographic percent density
NASA Astrophysics Data System (ADS)
Sak, Mark; Duric, Nebojsa; Boyd, Norman; Littrup, Peter; Myc, Lukasz; Faiz, Muhammad; Li, Cuiping; Bey-Knight, Lisa
2011-03-01
Despite some shortcomings, mammography is currently the standard of care for breast cancer screening and diagnosis. However, breast ultrasound tomography is a rapidly developing imaging modality that has the potential to overcome the drawbacks of mammography. It is known that women with high breast densities have a greater risk of developing breast cancer. Measuring breast density is accomplished through the use of mammographic percent density, defined as the ratio of fibroglandular to total breast area. Using an ultrasound tomography (UST) prototype, we created sound speed images of the patient's breast, motivated by the fact that sound speed in a tissue is proportional to the density of the tissue. The purpose of this work is to compare the acoustic performance of the UST system with the measurement of mammographic percent density. A cohort of 251 patients was studied using both imaging modalities and the results suggest that the volume averaged breast sound speed is significantly related to mammographic percent density. The Spearman correlation coefficient was found to be 0.73 for the 175 film mammograms and 0.69 for the 76 digital mammograms obtained. Since sound speed measurements do not require ionizing radiation or physical compression, they have the potential to form the basis of a safe, more accurate surrogate marker of breast density.
NASA Astrophysics Data System (ADS)
Yngvesson, Sigfrid K.; St. Peter, Benjamin; Siqueira, Paul; Kelly, Patrick; Glick, Stephen; Karellas, Andrew; Khan, Ashraf
2012-03-01
In breast conservation surgery, surgeons attempt to remove malignant tissue along with a surrounding margin of healthy tissue. Subsequent pathological analysis determines if those margins are clear of malignant tissue, a process that typically requires at least one day. Only then can it be determined whether a follow-up surgery is necessary. This possibility of re-excision is undesirable in terms of reducing patient morbidity, emotional stress and healthcare. It has been shown that terahertz (THz) images of breast specimens can accurately differentiate between breast carcinoma, normal fibroglandular tissue, and adipose tissue. That study employed the Time-Domain Spectroscopy (TDS) technique. We are instead developing a new technique, Frequency-Domain Terahertz Imaging (FDTI). In this joint project between UMass/Amherst and UMass Medical School/Worcester (UMMS), we are investigating the feasibility of the FDTI technique for THz reflection imaging of breast cancer margins. Our system, which produces mechanically scanned images of size 2cm x 2cm, uses a THz gas laser. The system is calibrated with mixtures of water and ethanol and reflection coefficients as low as 1% have been measured. Images from phantoms and specimens cut from breast cancer lumpectomies at UMMS will be presented. Finally, there will be a discussion of a possible transition of this FDTI setup to a compact and inexpensive CMOS THz camera for use in the operating room.
Sub-mSV breast XACT scanner: concept and design
NASA Astrophysics Data System (ADS)
Tang, Shanshan; Ren, Liqiang; Samant, Pratik; Chen, Jian; Liu, Hong; Xiang, Liangzhong
2016-04-01
Excessive exposure to radiation increases the risk of cancer. We present the concept and design of a new imaging paradigm, X-ray induced acoustic computed tomography (XACT). Applying this innovative technology to breast imaging, one single X-ray exposure can generate a 3D acoustic image, which dramatically reduces the radiation dose to patients when compared to beast CT. A theoretical model is developed to analyze the sensitivity of XACT. A noise equivalent pressure model is used for calculating the minimal radiation dose in XACT imaging. Furthermore, K-Wave simulation is employed to study the acoustic wave propagation in breast tissue. Theoretical analysis shows that the X-ray induced acoustic signal has a 100% relative sensitivity to the X-ray absorption (given that the percentage change in the X-ray absorption coefficient yields the same percentage change in the acoustic signal amplitude), but not to X-ray scattering. The final detection sensitivity is primarily limited by the thermal noise. The radiation dose can be reduced by a factor of 100 compared with the newly FDA approved breast CT. Reconstruction result shows that breast calcification with diameter of 80 μm can be observed in XACT image by using ultrasound transducers with 5.5 MHz center frequency. Therefore, with the proposed innovative technology, one can potentially reduce radiation dose to patient in breast imaging as compared with current x-ray modalities.
Multi-Band Miniaturized Patch Antennas for a Compact, Shielded Microwave Breast Imaging Array.
Aguilar, Suzette M; Al-Joumayly, Mudar A; Burfeindt, Matthew J; Behdad, Nader; Hagness, Susan C
2013-12-18
We present a comprehensive study of a class of multi-band miniaturized patch antennas designed for use in a 3D enclosed sensor array for microwave breast imaging. Miniaturization and multi-band operation are achieved by loading the antenna with non-radiating slots at strategic locations along the patch. This results in symmetric radiation patterns and similar radiation characteristics at all frequencies of operation. Prototypes were fabricated and tested in a biocompatible immersion medium. Excellent agreement was obtained between simulations and measurements. The trade-off between miniaturization and radiation efficiency within this class of patch antennas is explored via a numerical analysis of the effects of the location and number of slots, as well as the thickness and permittivity of the dielectric substrate, on the resonant frequencies and gain. Additionally, we compare 3D quantitative microwave breast imaging performance achieved with two different enclosed arrays of slot-loaded miniaturized patch antennas. Simulated array measurements were obtained for a 3D anatomically realistic numerical breast phantom. The reconstructed breast images generated from miniaturized patch array data suggest that, for the realistic noise power levels assumed in this study, the variations in gain observed across this class of multi-band patch antennas do not significantly impact the overall image quality. We conclude that these miniaturized antennas are promising candidates as compact array elements for shielded, multi-frequency microwave breast imaging systems.
Wu, Shibin; Zhuang, Ling; Wei, Xinhua; Sak, Mark; Neb, Duric; Hu, Jiani; Xie, Yaoqin
2017-01-01
As an emerging modality for whole breast imaging, ultrasound tomography (UST), has been adopted for diagnostic purposes. Efficient segmentation of an entire breast in UST images plays an important role in quantitative tissue analysis and cancer diagnosis, while major existing methods suffer from considerable time consumption and intensive user interaction. This paper explores three-dimensional GrabCut (GC3D) for breast isolation in thirty reflection (B-mode) UST volumetric images. The algorithm can be conveniently initialized by localizing points to form a polygon, which covers the potential breast region. Moreover, two other variations of GrabCut and an active contour method were compared. Algorithm performance was evaluated from volume overlap ratios (TO, target overlap; MO, mean overlap; FP, false positive; FN, false negative) and time consumption. Experimental results indicate that GC3D considerably reduced the work load and achieved good performance (TO = 0.84; MO = 0.91; FP = 0.006; FN = 0.16) within an average of 1.2 min per volume. Furthermore, GC3D is not only user friendly, but also robust to various inputs, suggesting its great potential to facilitate clinical applications during whole-breast UST imaging. In the near future, the implemented GC3D can be easily automated to tackle B-mode UST volumetric images acquired from the updated imaging system. PMID:28786946
NASA Astrophysics Data System (ADS)
Dobbs, Jessica; Kyrish, Matthew; Krishnamurthy, Savitri; Grant, Benjamin; Kuerer, Henry; Yang, Wei; Tkaczyk, Tomasz; Richards-Kortum, Rebecca
2016-03-01
Intraoperative margin assessment to evaluate resected tissue margins for neoplastic tissue is performed to prevent reoperations following breast-conserving surgery. High resolution microendoscopy (HRME) can rapidly acquire images of fresh tissue specimens, but is limited by low image contrast in tissues with high optical scattering. In this study we evaluated two techniques to reduce out-of-focus light: HRME image acquisition with structured illumination (SI-HRME) and topical application of Lugol's Iodine. Fresh breast tissue specimens from 19 patients were stained with proflavine alone or Lugol's Iodine and proflavine. Images of tissue specimens were acquired using a confocal microscope and an HRME system with and without structured illumination. Images were evaluated based on visual and quantitative assessment of image contrast. The highest mean contrast was measured in confocal images stained with proflavine. Contrast was significantly lower in HRME images stained with proflavine; however, incorporation of structured illumination significantly increased contrast in HRME images to levels comparable to that in confocal images. The addition of Lugol's Iodine did not increase mean contrast significantly for HRME or SI-HRME images. These findings suggest that structured illumination could potentially be used to increase contrast in HRME images of breast tissue for rapid image acquisition.
Brédart, Anne; Kop, Jean-Luc; Fall, Mouhamadou; Pelissier, Sandra; Simondi, Cécile; Dolbeault, Sylvie; Livartowski, Alain; Tardivon, Anne
2012-11-01
Intensive surveillance in women at intermediate and high breast cancer risk is currently investigated in a French prospective, non-randomized, multicentre study. Two surveillance modalities, standard imaging-mammography ± ultrasound ('Mx')-or standard imaging with magnetic resonance imaging ('MRI'), provided according to the level of breast cancer risk, are compared on psychological distress. A total of 1561 women were invited to complete the State-Trait Anxiety Inventory (STAI), Impact of Event Scale (IES) Intrusion and Avoidance subscales and breast cancer-risk perception items at T0 (before examination) and T2 (1 to 3 months later) and the STAI-State anxiety at T1 (just after examination). Multiple regression analyses were performed. Baseline compliance was high (>91%). Between surveillance modalities, women differed significantly for age, education level, breast cancer-risk objective estimates and subjective perception. Mean STAI-State anxiety scores reflected low to moderate distress in both surveillance modalities. At baseline, MRI was associated with lower STAI-State anxiety (p ≤ 0.001) and Avoidance scores (p = 0.02), but at T1 and T2, no difference between surveillance modalities was observed on psychological outcomes. Abnormal surveillance result was associated with a higher STAI-State anxiety (p ≤ 0.01) and IES-Intrusion (p ≤ 0.01) scores; a personal history of breast cancer and higher risk perception was associated with higher psychological distress at T1 and T2. Standard breast imaging including MRI does not seem to convey more harmful psychological effects than standard imaging alone. Higher psychological distress observed in the case of history of breast cancer or higher breast cancer-risk perception evidences women with needs for specific support and information. Copyright © 2011 John Wiley & Sons, Ltd.
Wu, Lian-Ming; Chen, Jie; Hu, Jiani; Gu, Hai-Yan; Xu, Jian-Rong; Hua, Jia
2014-02-01
Breast cancer is the most common cancer in women worldwide. However, it remains a difficult diagnosis problem to differentiate between benign and malignant breast lesions, especially in small early breast lesions. To assess the diagnostic value of diffusion-weighted imaging (DWI) combined with T2-weighted imaging (T2WI) for small breast cancer characterization. Fifty-eight patients (65 lesions) with a lesion <2 cm in diameter underwent 3.0 Tesla breast magnetic resonance imaging (MRI) including DWI and histological analysis. Three observers with varying experience levels reviewed MRI. The probability of breast cancer in each lesion on MR images was recorded with a 5-point scale. Areas under the receiver-operating characteristic curve (AUCs) were compared by using the Z test; sensitivity and specificity were determined with the Z test after adjusting for data clustering. AUC of T2WI and DWI (Observer 1, 0.95; Observer 2, 0.91; Observer 3, 0.83) was greater than that of T2WI (Observer 1, 0.80; Observer 2, 0.74; Observer 3, 0.70) for all observers (P < 0.0001 in all comparisons). Sensitivity of T2WI and DWI (Observer 1, 90%; Observer 2, 93%; and Observer 3, 86%) was greater than that of T2WI alone (Observer 1, 76%; Observer 2, 83%; Observer 3, 79%) for all observers (P < 0.0001 in all comparisons). Specificity of T2WI and DWI was greater than that of T2WI alone for observer 1 (89% vs. 72%, P < 0.01) and observer 2 (94% vs. 78%, P < 0.001). DWI combined with T2WI can improve the diagnostic performance of MRI in small breast cancer characterization. It should be considered selectively in the preoperative evaluation of patients with small lesions of the breast.
X-ray phase-contrast imaging of the breast—advances towards clinical implementation
Herzen, J; Willner, M; Grandl, S; Scherer, K; Bamberg, F; Reiser, M F; Pfeiffer, F; Hellerhoff, K
2014-01-01
Breast cancer constitutes about one-quarter of all cancers and is the leading cause of cancer death in women. To reduce breast cancer mortality, mammographic screening programmes have been implemented in many Western countries. However, these programmes remain controversial because of the associated radiation exposure and the need for improvement in terms of diagnostic accuracy. Phase-contrast imaging is a new X-ray-based technology that has been shown to provide enhanced soft-tissue contrast and improved visualization of cancerous structures. Furthermore, there is some indication that these improvements of image quality can be maintained at reduced radiation doses. Thus, X-ray phase-contrast mammography may significantly contribute to advancements in early breast cancer diagnosis. Feasibility studies of X-ray phase-contrast breast CT have provided images that allow resolution of the fine structure of tissue that can otherwise only be obtained by histology. This implies that X-ray phase-contrast imaging may also lead to the development of entirely new (micro-) radiological applications. This review provides a brief overview of the physical characteristics of this new technology and describes recent developments towards clinical implementation of X-ray phase-contrast imaging of the breast. PMID:24452106
NASA Astrophysics Data System (ADS)
Riantana, R.; Arie, B.; Adam, M.; Aditya, R.; Nuryani; Yahya, I.
2017-02-01
One important thing to pay attention for detecting breast cancer is breast temperature changes. Indications symptoms of breast tissue abnormalities marked by a rise in temperature of the breast. Handycam in night vision mode interferences by external infrared can penetrate into the skin better and can make an infrared image becomes clearer. The program is capable to changing images from a camcorder into a night vision thermal image by breaking RGB into Grayscale matrix structure. The matrix rearranged in the new matrix with double data type so that it can be processed into contour color chart to differentiate the distribution of body temperature. In this program are also features of contrast scale setting of the image is processed so that the color can be set as desired. There was Also a contrast adjustment feature inverse scale that is useful to reverse the color scale so that colors can be changed opposite. There is improfile function used to retrieves the intensity values of pixels along a line what we want to show the distribution of intensity in a graph of relationship between the intensity and the pixel coordinates.
NASA Astrophysics Data System (ADS)
Kopeć, Monika; Abramczyk, Halina
2018-06-01
Combined micro-Raman imaging and AFM imaging are efficient methods for analyzing human tissue due to their high spatial and spectral resolution as well as sensitivity to subtle chemical, structural and topographical changes. The aim of this study was to determine biochemical composition and mechanical topography around blood vessels in the tumor mass of human breast tissue. Significant alterations of the chemical composition and structural architecture around the blood vessel were found compared to the normal breast tissue. A pronounced increase of collagen-fibroblast-glycocalyx network, as well as enhanced lactic acid, and glycogen activity in patients affected by breast cancer were reported.
Clark, Andrea J.; Petty, Howard R.
2016-01-01
This protocol describes the methods and steps involved in performing biomarker ratio imaging microscopy (BRIM) using formalin fixed paraffin-embedded (FFPE) samples of human breast tissue. The technique is based on the acquisition of two fluorescence images of the same microscopic field using two biomarkers and immunohistochemical tools. The biomarkers are selected such that one biomarker correlates with breast cancer aggressiveness while the second biomarker anti-correlates with aggressiveness. When the former image is divided by the latter image, a computed ratio image is formed that reflects the aggressiveness of tumor cells while increasing contrast and eliminating path-length and other artifacts from the image. For example, the aggressiveness of epithelial cells may be assessed by computing ratio images of N-cadherin and E-cadherin images or CD44 and CD24 images, which specifically reflect the mesenchymal or stem cell nature of the constituent cells, respectively. This methodology is illustrated for tissue samples of ductal carcinoma in situ (DCIS) and invasive breast cancer. This tool should be useful in tissue studies of experimental cancer as well as the management of cancer patients. PMID:27857940
Fingeret, Michelle Cororve; Nipomnick, Summer; Crosby, Melissa A.; Reece, Gregory P.
2013-01-01
Within the field of breast reconstruction there is increasing focus on patient-reported outcomes related to satisfaction, body image, and quality of life. These outcomes are deemed highly relevant because the primary goal of breast reconstruction is to recreate the appearance of a breast (or breasts) that is satisfying to the patient. Prominent researchers have suggested the need to develop improved standards for outcome evaluation which can ultimately benefit patients as well as physicians. The purpose of this article is to summarize key findings in the area of patient-reported outcomes for breast reconstruction and introduce a theoretical framework for advancing research in this field. We conducted an extensive literature review of outcome studies for breast reconstruction focusing on patient-reported results. We developed a theoretical framework illustrating core patient-reported outcomes related to breast reconstruction and factors associated with these outcomes. Our theoretical model highlights domains and distinguishing features of patient satisfaction, body image, and quality of life outcomes for women undergoing breast reconstruction. This model further identifies a broad range of variables (e.g., historical/premorbid influences, disease and treatment-related factors) that have been found to influence patient-reported outcomes and need to be taken into consideration when designing future research in this area. Additional attention is given to examining the relationship between patient reported outcomes and outside evaluation of breast reconstruction. Our proposed theoretical framework suggests key opportunities to expand research in this area with the goal of optimizing body image adjustment, satisfaction, and psychosocial outcomes for the individual patient. PMID:23380309
Song, Lei; Li, Liang; Liu, Bin; Yu, Dexin; Sun, Fengguo; Guo, Mingming; Ruan, Zhengmin; Zhang, Feixue
2018-01-01
The objective of the present study was to evaluate the diagnostic efficiency of ultrasound (US) and magnetic resonance imaging (MRI) in the diagnosis and differential diagnosis of mammary duct ectasia (MDE) and breast cancer. This retrospective study was performed on 35 patients with MDE and 105 patients with breast cancer using US and MRI. Imaging features, semi-quantitative and quantitative parameters were analyzed to determine their diagnostic value for MDE and breast cancer. The average age of patients with breast cancer was increased compared with that of patients with MDE. There were no significant differences in local packages with or without tenderness ratio (P=0.259) and grade of color Doppler flow imaging (P=0.273) between the two groups. However, the morphological changes were significantly increased in breast cancer compared with MDE. In addition, there were significant diagnostic differences in US and MRI between breast cancer and MDE, including resistance index, US elastography, time-signal intensity curve, apparent diffusion coefficient, early-stage enhancement ratio, peak-of-enhancement ratio and Tpeak (P<0.05). However, there were no observable significant diagnostic differences between US, MRI and US with MRI for MDE and breast cancer (P=0.103, P=0.263 and P=0.403 respectively). Diagnosis of MDE and breast cancer requires full evaluation of multiple parameters and morphological changes of US and MRI to increase the diagnostic efficiency. US, MRI and US with MRI were all of diagnostic value for MDE and breast cancer, while US with MRI had the highest efficacy. PMID:29434865
Breast boundary detection with active contours
NASA Astrophysics Data System (ADS)
Balic, I.; Goyal, P.; Roy, O.; Duric, N.
2014-03-01
Ultrasound tomography is a modality that can be used to image various characteristics of the breast, such as sound speed, attenuation, and reflectivity. In the considered setup, the breast is immersed in water and scanned along the coronal axis from the chest wall to the nipple region. To improve image visualization, it is desirable to remove the water background. To this end, the 3D boundary of the breast must be accurately estimated. We present an iterative algorithm based on active contours that automatically detects the boundary of a breast using a 3D stack of attenuation images obtained from an ultrasound tomography scanner. We build upon an existing method to design an algorithm that is fast, fully automated, and reliable. We demonstrate the effectiveness of the proposed technique using clinical data sets.
Association Between Imaging Characteristics and Different Molecular Subtypes of Breast Cancer.
Wu, Mingxiang; Ma, Jie
2017-04-01
Breast cancer can be divided into four major molecular subtypes based on the expression of hormone receptor (estrogen receptor and progesterone receptor), human epidermal growth factor receptor 2, HER2 status, and molecular proliferation rate (Ki67). In this study, we sought to investigate the association between breast cancer subtype and radiological findings in the Chinese population. Medical records of 300 consecutive invasive breast cancer patients were reviewed from the database: the Breast Imaging Reporting and Data System. The imaging characteristics of the lesions were evaluated. The molecular subtypes of breast cancer were classified into four types: luminal A, luminal B, HER2 overexpressed (HER2), and basal-like breast cancer (BLBC). Univariate and multivariate logistic regression analyses were performed to assess the association between the subtype (dependent variable) and mammography or 15 magnetic resonance imaging (MRI) indicators (independent variables). Luminal A and B subtypes were commonly associated with "clustered calcification distribution," "nipple invasion," or "skin invasion" (P <0.05). The BLBC subtype was more commonly associated with "rim enhancement" and persistent inflow type enhancement in delayed phase (P <0.05). HER2 overexpressed cancers showed association with persistent enhancement in the delayed phase on MRI and "clustered calcification distribution" on mammography (P <0.05). Certain radiological features are strongly associated with the molecular subtype and hormone receptor status of breast tumor, which are potentially useful tools in the diagnosis and subtyping of breast cancer. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
3 Tesla breast MR imaging as a problem-solving tool: Diagnostic performance and incidental lesions
Spick, Claudio; Szolar, Dieter H. M.; Preidler, Klaus W.; Reittner, Pia; Rauch, Katharina; Brader, Peter; Tillich, Manfred
2018-01-01
Purpose To investigate the diagnostic performance and incidental lesion yield of 3T breast MRI if used as a problem-solving tool. Methods This retrospective, IRB-approved, cross-sectional, single-center study comprised 302 consecutive women (mean: 50±12 years; range: 20–79 years) who were undergoing 3T breast MRI between 03/2013-12/2014 for further workup of conventional and clinical breast findings. Images were read by experienced, board-certified radiologists. The reference standard was histopathology or follow-up ≥ two years. Sensitivity, specificity, PPV, and NPV were calculated. Results were stratified by conventional and clinical breast findings. Results The reference standard revealed 53 true-positive, 243 true-negative, 20 false-positive, and two false-negative breast MRI findings, resulting in a sensitivity, specificity, PPV, and NPV of 96.4% (53/55), 92.4% (243/263), 72.6% (53/73), and 99.2% (243/245), respectively. In 5.3% (16/302) of all patients, incidental MRI lesions classified BI-RADS 3–5 were detected, 37.5% (6/16) of which were malignant. Breast composition and the imaging findings that had led to referral had no significant influence on the diagnostic performance of breast MR imaging (p>0.05). Conclusion 3T breast MRI yields excellent diagnostic results if used as a problem-solving tool independent of referral reasons. The number of suspicious incidental lesions detected by MRI is low, but is associated with a substantial malignancy rate. PMID:29293582
Screening breast magnetic resonance imaging in women with atypia or lobular carcinoma in situ.
Schwartz, Theresa; Cyr, Amy; Margenthaler, Julie
2015-02-01
Atypical lesions and lobular carcinoma in situ (LCIS) are associated with an increased risk of breast malignancy. The utility of breast magnetic resonance imaging (MRI) screening in this cohort of women after excision of a high-risk lesion has not been previously established. The objective of this study was to investigate outcomes of breast MRI surveillance in this subgroup of high-risk patients. We performed a retrospective review of women who required excision of an atypical lesion or LCIS who underwent at least one screening breast MRI from April 2005-December 2011. We collected information on demographics, number of second-look imaging studies recommended, number of biopsies performed and pathologic outcomes. A total of 179 patients met the inclusion criteria, including 131 (73%) with atypical lesions and 48 (27%) with LCIS. Second-look imaging was recommended for 31 of 131 (23.7%) patients with atypical lesions and 8 of 48 (16.7%) with LCIS. Ten biopsies were performed in the atypical cohort (7.6%) with two revealing a malignancy (Positive Predictive Value [PPV] of 20%). In the LCIS cohort, five biopsies were performed (10.4%) with one revealing a malignancy (PPV of 20%). The benefit of breast MRI surveillance in patients after excision of atypical lesions or LCIS has not been clearly delineated previously. Our data demonstrate that the use of screening breast MRI in this cohort results in additional work-up in one-fifth of patients, but a PPV of only 20%. Large, prospective studies would be needed to determine whether breast cancer outcomes differ between patients undergoing conventional breast screening and those undergoing conventional breast screening plus breast MRI surveillance. Copyright © 2015 Elsevier Inc. All rights reserved.
A case-oriented web-based training system for breast cancer diagnosis.
Huang, Qinghua; Huang, Xianhai; Liu, Longzhong; Lin, Yidi; Long, Xingzhang; Li, Xuelong
2018-03-01
Breast cancer is still considered as the most common form of cancer as well as the leading causes of cancer deaths among women all over the world. We aim to provide a web-based breast ultrasound database for online training inexperienced radiologists and giving computer-assisted diagnostic information for detection and classification of the breast tumor. We introduce a web database which stores breast ultrasound images from breast cancer patients as well as their diagnostic information. A web-based training system using a feature scoring scheme based on Breast Imaging Reporting and Data System (BI-RADS) US lexicon was designed. A computer-aided diagnosis (CAD) subsystem was developed to assist the radiologists to make scores on the BI-RADS features for an input case. The training system possesses 1669 scored cases, where 412 cases are benign and 1257 cases are malignant. It was tested by 31 users including 12 interns, 11 junior radiologists, and 8 experienced senior radiologists. This online training system automatically creates case-based exercises to train and guide the newly employed or resident radiologists for the diagnosis of breast cancer using breast ultrasound images based on the BI-RADS. After the trainings, the interns and junior radiologists show significant improvement in the diagnosis of the breast tumor with ultrasound imaging (p-value < .05); meanwhile the senior radiologists show little improvement (p-value > .05). The online training system can improve the capabilities of early-career radiologists in distinguishing between the benign and malignant lesions and reduce the misdiagnosis of breast cancer in a quick, convenient and effective manner. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.
Impact of body image on depression and quality of life among women with breast cancer.
Begovic-Juhant, Ana; Chmielewski, Amy; Iwuagwu, Stella; Chapman, Lauren A
2012-01-01
The purpose of this study was to explore body image, physical attractiveness, and femininity among survivors of breast cancer and to examine the effects of the aforementioned variables on depression and quality of life. The participants comprised 70 female survivors of breast cancer, ages between 23 and 79 years. They completed a questionnaire that includes Center for Epidemiological Studies Depression Scale, Functional Assessment of Cancer Therapy, and European Organization for the Research and Treatment of Cancer Quality of Life Questionnaire--Breast Cancer, measuring depression, quality of life, and body image, respectively. On the depression scale, 56% of the participants had scores higher than 16; a score of 16 and above identifies participants with potential depression. Majority of women felt less attractive and less feminine. Low body image, attractiveness, and femininity positively correlated with depression and negatively with overall quality of life. The authors conclude that multidisciplinary health care services relevant to physical attractiveness and femininity of survivors of breast cancer may foster positive body image perceptions, reduced depression, and increased quality of life.
NASA Astrophysics Data System (ADS)
Qin, Xulei; Lu, Guolan; Sechopoulos, Ioannis; Fei, Baowei
2014-03-01
Digital breast tomosynthesis (DBT) is a pseudo-three-dimensional x-ray imaging modality proposed to decrease the effect of tissue superposition present in mammography, potentially resulting in an increase in clinical performance for the detection and diagnosis of breast cancer. Tissue classification in DBT images can be useful in risk assessment, computer-aided detection and radiation dosimetry, among other aspects. However, classifying breast tissue in DBT is a challenging problem because DBT images include complicated structures, image noise, and out-of-plane artifacts due to limited angular tomographic sampling. In this project, we propose an automatic method to classify fatty and glandular tissue in DBT images. First, the DBT images are pre-processed to enhance the tissue structures and to decrease image noise and artifacts. Second, a global smooth filter based on L0 gradient minimization is applied to eliminate detailed structures and enhance large-scale ones. Third, the similar structure regions are extracted and labeled by fuzzy C-means (FCM) classification. At the same time, the texture features are also calculated. Finally, each region is classified into different tissue types based on both intensity and texture features. The proposed method is validated using five patient DBT images using manual segmentation as the gold standard. The Dice scores and the confusion matrix are utilized to evaluate the classified results. The evaluation results demonstrated the feasibility of the proposed method for classifying breast glandular and fat tissue on DBT images.
NASA Astrophysics Data System (ADS)
Yu, Yang
Near-infrared spectral imaging for breast cancer diagnostics and monitoring has been a hot research topic for the past decade. Here we present instrumentation for diffuse optical imaging of breast tissue with tandem scan of a single source-detector pair with broadband light in transmission geometry for tissue oximetry. The efforts to develop the continuous-wave (CW) domain instrument have been described, and a frequency-domain (FD) system is also used to measure the bulk tissue optical properties and the breast thickness distribution. We also describe the efforts to improve the data processing codes in the 2D spatial domain for better noise suppression, contrast enhancement, and spectral analysis. We developed a paired-wavelength approach, which is based on finding pairs of wavelength that feature the same optical contrast, to quantify the tissue oxygenation for the absorption structures detected in the 2D structural image. A total of eighteen subjects, two of whom were bearing breast cancer on their right breasts, were measured with this hybrid CW/FD instrument and processed with the improved algorithms. We obtained an average tissue oxygenation value of 87% +/- 6% from the healthy breasts, significantly higher than that measured in the diseased breasts (69% +/- 14%) (p < 0.01). For the two diseased breasts, the tumor areas bear hypoxia signatures versus the remainder of the breast, with oxygenation values of 49 +/- 11% (diseased region) vs. 61 +/- 16% (healthy regions) for the breast with invasive ductal carcinoma, and 58 +/- 8% (diseased region) vs 77 +/- 11% (healthy regions) for ductal carcinoma in situ. Our subjects came from various ethnical/racial backgrounds, and two-thirds of our subjects were less than thirty years old, indicating a potential to apply the optical mammography to a broad population. The second part of this thesis covers the topic of depth discrimination, which is lacking with our single source-detector scan system. Based on an off-axis detection method, we incorporated an additional detector to acquire a second set of image independently. We then proposed an inner-product approach to associate absorption structures detected in the on-axis image with those detected in the off-axis image. The spatial coordinate difference for the same structure between the two images is directly related to the depth of the corresponding structure, and the monotonic dependence can be quantified by perturbation theory of the diffusion equation. A preliminary phantom study shows good agreement between the measured and the actual depth of embedded structures, and human measurements show the capability to assign a depth coordinate to the more complex absorption structures inside the breast.
Cho, Hyo-Min; Ding, Huanjun; Barber, William C; Iwanczyk, Jan S; Molloi, Sabee
2015-07-01
To investigate the feasibility of detecting breast microcalcification (μCa) with a dedicated breast computed tomography (CT) system based on energy-resolved photon-counting silicon (Si) strip detectors. The proposed photon-counting breast CT system and a bench-top prototype photon-counting breast CT system were simulated using a simulation package written in matlab to determine the smallest detectable μCa. A 14 cm diameter cylindrical phantom made of breast tissue with 20% glandularity was used to simulate an average-sized breast. Five different size groups of calcium carbonate grains, from 100 to 180 μm in diameter, were simulated inside of the cylindrical phantom. The images were acquired with a mean glandular dose (MGD) in the range of 0.7-8 mGy. A total of 400 images was used to perform a reader study. Another simulation study was performed using a 1.6 cm diameter cylindrical phantom to validate the experimental results from a bench-top prototype breast CT system. In the experimental study, a bench-top prototype CT system was constructed using a tungsten anode x-ray source and a single line 256-pixels Si strip photon-counting detector with a pixel pitch of 100 μm. Calcium carbonate grains, with diameter in the range of 105-215 μm, were embedded in a cylindrical plastic resin phantom to simulate μCas. The physical phantoms were imaged at 65 kVp with an entrance exposure in the range of 0.6-8 mGy. A total of 500 images was used to perform another reader study. The images were displayed in random order to three blinded observers, who were asked to give a 4-point confidence rating on each image regarding the presence of μCa. The μCa detectability for each image was evaluated by using the average area under the receiver operating characteristic curve (AUC) across the readers. The simulation results using a 14 cm diameter breast phantom showed that the proposed photon-counting breast CT system can achieve high detection accuracy with an average AUC greater than 0.89 ± 0.07 for μCas larger than 120 μm in diameter at a MGD of 3 mGy. The experimental results using a 1.6 cm diameter breast phantom showed that the prototype system can achieve an average AUC greater than 0.98 ± 0.01 for μCas larger than 140 μm in diameter using an entrance exposure of 1.2 mGy. The proposed photon-counting breast CT system based on a Si strip detector can potentially offer superior image quality to detect μCa with a lower dose level than a standard two-view mammography.
Gopie, Jessica P; Mureau, Marc A M; Seynaeve, Caroline; Ter Kuile, Moniek M; Menke-Pluymers, Marian B E; Timman, Reinier; Tibben, Aad
2013-09-01
The outcome of bilateral prophylactic mastectomy with breast reconstruction (BPM-IBR) in healthy BRCA1/2 mutation carriers can be potentially burdensome for body image and the intimate relationship. Therefore, in the current analysis the impact on body image, sexual and partner relationship satisfaction was prospectively investigated in women opting for BPM-IBR as well as cancer distress and general quality of life. Healthy women undergoing BPM-IBR completed questionnaires preoperatively (T0, n = 48), at 6 months (T1, n = 44) and after finishing breast reconstruction (median 21 months, range 12-35) (T2, n = 36). With multi-level regression analyses the course of outcome variables was investigated and a statistically significant change in body image and/or sexual and partner relationship satisfaction was predicted by baseline covariates. Body image significantly decreased at T1. At T2 sexual relationship satisfaction and body image tended to be lower compared to baseline. The overall partner relationship satisfaction did not significantly change. At T2, 37 % of the women reported that their breasts felt unpleasantly, 29 % was not satisfied with their breast appearance and 21 % felt embarrassed for their naked body. Most body image issues remained unchanged in 30 % of the women. A negative body image was predicted by high preoperative cancer distress. BPM-IBR was associated with adverse impact on body image in a substantial subgroup, but satisfaction with the overall sexual and partner relationship did not significantly change in time. The psychosocial impact of BPM-IBR in unaffected women should not be underestimated. Psychological support should ideally be integrated both before and after BPM-IBR.
Schmidt, Steven; Duric, Nebojsa; Li, Cuiping; Roy, Olivier; Huang, Zhi-Feng
2011-01-01
Purpose: To explore the feasibility of improving cross-sectional reflection imaging of the breast using refractive and attenuation corrections derived from ultrasound tomography data. Methods: The authors have adapted the planar Kirchhoff migration method, commonly used in geophysics to reconstruct reflection images, for use in ultrasound tomography imaging of the breast. Furthermore, the authors extended this method to allow for refractive and attenuative corrections. Using clinical data obtained with a breast imaging prototype, the authors applied this method to generate cross-sectional reflection images of the breast that were corrected using known distributions of sound speed and attenuation obtained from the same data. Results: A comparison of images reconstructed with and without the corrections showed varying degrees of improvement. The sound speed correction resulted in sharpening of detail, while the attenuation correction reduced the central darkening caused by path length dependent losses. The improvements appeared to be greatest when dense tissue was involved and the least for fatty tissue. These results are consistent with the expectation that denser tissues lead to both greater refractive effects and greater attenuation. Conclusions: Although conventional ultrasound techniques use time-gain control to correct for attenuation gradients, these corrections lead to artifacts because the true attenuation distribution is not known. The use of constant sound speed leads to additional artifacts that arise from not knowing the sound speed distribution. The authors show that in the context of ultrasound tomography, it is possible to construct reflection images of the breast that correct for inhomogeneous distributions of both sound speed and attenuation. PMID:21452737
Breast cancer histopathology image analysis: a review.
Veta, Mitko; Pluim, Josien P W; van Diest, Paul J; Viergever, Max A
2014-05-01
This paper presents an overview of methods that have been proposed for the analysis of breast cancer histopathology images. This research area has become particularly relevant with the advent of whole slide imaging (WSI) scanners, which can perform cost-effective and high-throughput histopathology slide digitization, and which aim at replacing the optical microscope as the primary tool used by pathologist. Breast cancer is the most prevalent form of cancers among women, and image analysis methods that target this disease have a huge potential to reduce the workload in a typical pathology lab and to improve the quality of the interpretation. This paper is meant as an introduction for nonexperts. It starts with an overview of the tissue preparation, staining and slide digitization processes followed by a discussion of the different image processing techniques and applications, ranging from analysis of tissue staining to computer-aided diagnosis, and prognosis of breast cancer patients.
Keto, Jessica L; Kirstein, Laurie; Sanchez, Diana P; Fulop, Tamara; McPartland, Laura; Cohen, Ilona; Boolbol, Susan K
2012-01-01
Mammography remains the standard imaging technique for the diagnosis of ductal carcinoma-in-situ (DCIS). Functional breast imaging, including breast magnetic resonance imaging (MRI), has known limitations in evaluating DCIS. To date, there are limited data on the utility of breast-specific gamma imaging (BSGI) in DCIS. We sought to prospectively compare the sensitivity of BSGI to MRI in newly diagnosed DCIS patients. Patients with newly diagnosed DCIS from June 1, 2009, through May 31, 2010, underwent a protocol with both breast MRI and BSGI. Each imaging study was read by a separate dedicated breast radiologist. Patients were excluded if excisional biopsy was performed for diagnosis, if their MRI was performed at an outside facility, or if final pathology revealed invasive carcinoma. There were 18 patients enrolled onto the study that had both MRI and BSGI for newly diagnosed DCIS. The sensitivity for MRI was 94% and for BSGI was 89% (P > 0.5, NS). There was one index tumor not seen on either MRI or BSGI, and one index tumor seen on MRI but not visualized on BSGI. Although BSGI has previously been shown to be as sensitive as MRI for detecting known invasive breast carcinoma, this study shows that BSGI is equally as sensitive as MRI at detecting newly diagnosed DCIS. As a result of the limited number of patients enrolled onto the study, larger prospective studies need to be performed to determine the true sensitivity and specificity of BSGI.
Brachtel, Elena F.; Johnson, Nicole B.; Huck, Amelia E.; Rice-Stitt, Travis L.; Vangel, Mark G.; Smith, Barbara L.; Tearney, Guillermo J.; Kang, Dongkyun
2016-01-01
A large percentage of breast cancer patients treated with breast conserving surgery need to undergo multiple surgeries due to positive margins found during post-operative margin assessment. Carcinomas could be removed completely during the initial surgery and additional surgery avoided if positive margins can be determined intra-operatively. Spectrally-encoded confocal microscopy (SECM) is a high-speed reflectance confocal microscopy technology that has a potential to rapidly image the entire surgical margin at sub-cellular resolution and accurately determine margin status intra-operatively. In this paper, in order to test feasibility of using SECM for intra-operative margin assessment, we have evaluated the diagnostic accuracy of SECM for detecting various types of breast cancers. Forty-six surgically-removed breast specimens were imaged with a SECM system. Side-by-side comparison between SECM and histologic images showed that SECM images can visualize key histomorphologic patterns of normal/benign and malignant breast tissues. Small (500 µm × 500 µm) spatially-registered SECM and histologic images (n=124 for each) were diagnosed independently by three pathologists with expertise in breast pathology. Diagnostic accuracy of SECM for determining malignant tissues was high, average sensitivity of 0.91, specificity of 0.93, positive predictive value of 0.95, and negative predictive value of 0.87. Intra-observer agreement and inter-observer agreement for SECM were also high, 0.87 and 0.84, respectively. Results from this study suggest that SECM may be developed into an intra-operative margin assessment tool for guiding breast cancer excisions. PMID:26779830
Development of a Hampton University Program for Novel Breast Cancer Imaging and Therapy Research
2014-04-01
Award Number: W81XWH-09-1-0111 TITLE: “Development of a Hampton University Program for Novel Breast Cancer Imaging and Therapy Research...a Hampton University Program for Novel Breast Cancer Imaaging and Therapy Research Nicholas Kenney, PhD Drew Weisenberger PhD Christopher Sinesci...cosmetic outcome of women with early stage breast cancers treated with MSB applicator and the spacing between the MammoSite balloon surface and the
Breast tissue stiffness estimation for surgical guidance using gravity-induced excitation
NASA Astrophysics Data System (ADS)
Griesenauer, Rebekah H.; Weis, Jared A.; Arlinghaus, Lori R.; Meszoely, Ingrid M.; Miga, Michael I.
2017-06-01
Tissue stiffness interrogation is fundamental in breast cancer diagnosis and treatment. Furthermore, biomechanical models for predicting breast deformations have been created for several breast cancer applications. Within these applications, constitutive mechanical properties must be defined and the accuracy of this estimation directly impacts the overall performance of the model. In this study, we present an image-derived computational framework to obtain quantitative, patient specific stiffness properties for application in image-guided breast cancer surgery and interventions. The method uses two MR acquisitions of the breast in different supine gravity-loaded configurations to fit mechanical properties to a biomechanical breast model. A reproducibility assessment of the method was performed in a test-retest study using healthy volunteers and was further characterized in simulation. In five human data sets, the within subject coefficient of variation ranged from 10.7% to 27% and the intraclass correlation coefficient ranged from 0.91-0.944 for assessment of fibroglandular and adipose tissue stiffness. In simulation, fibroglandular content and deformation magnitude were shown to have significant effects on the shape and convexity of the objective function defined by image similarity. These observations provide an important step forward in characterizing the use of nonrigid image registration methodologies in conjunction with biomechanical models to estimate tissue stiffness. In addition, the results suggest that stiffness estimation methods using gravity-induced excitation can reliably and feasibly be implemented in breast cancer surgery/intervention workflows.
Breast Cancer Detection by B7-H3-Targeted Ultrasound Molecular Imaging.
Bachawal, Sunitha V; Jensen, Kristin C; Wilson, Katheryne E; Tian, Lu; Lutz, Amelie M; Willmann, Jürgen K
2015-06-15
Ultrasound complements mammography as an imaging modality for breast cancer detection, especially in patients with dense breast tissue, but its utility is limited by low diagnostic accuracy. One emerging molecular tool to address this limitation involves contrast-enhanced ultrasound using microbubbles targeted to molecular signatures on tumor neovasculature. In this study, we illustrate how tumor vascular expression of B7-H3 (CD276), a member of the B7 family of ligands for T-cell coregulatory receptors, can be incorporated into an ultrasound method that can distinguish normal, benign, precursor, and malignant breast pathologies for diagnostic purposes. Through an IHC analysis of 248 human breast specimens, we found that vascular expression of B7-H3 was selectively and significantly higher in breast cancer tissues. B7-H3 immunostaining on blood vessels distinguished benign/precursors from malignant lesions with high diagnostic accuracy in human specimens. In a transgenic mouse model of cancer, the B7-H3-targeted ultrasound imaging signal was increased significantly in breast cancer tissues and highly correlated with ex vivo expression levels of B7-H3 on quantitative immunofluorescence. Our findings offer a preclinical proof of concept for the use of B7-H3-targeted ultrasound molecular imaging as a tool to improve the diagnostic accuracy of breast cancer detection in patients. ©2015 American Association for Cancer Research.
Breast tissue stiffness estimation for surgical guidance using gravity-induced excitation.
Griesenauer, Rebekah H; Weis, Jared A; Arlinghaus, Lori R; Meszoely, Ingrid M; Miga, Michael I
2017-06-21
Tissue stiffness interrogation is fundamental in breast cancer diagnosis and treatment. Furthermore, biomechanical models for predicting breast deformations have been created for several breast cancer applications. Within these applications, constitutive mechanical properties must be defined and the accuracy of this estimation directly impacts the overall performance of the model. In this study, we present an image-derived computational framework to obtain quantitative, patient specific stiffness properties for application in image-guided breast cancer surgery and interventions. The method uses two MR acquisitions of the breast in different supine gravity-loaded configurations to fit mechanical properties to a biomechanical breast model. A reproducibility assessment of the method was performed in a test-retest study using healthy volunteers and was further characterized in simulation. In five human data sets, the within subject coefficient of variation ranged from 10.7% to 27% and the intraclass correlation coefficient ranged from 0.91-0.944 for assessment of fibroglandular and adipose tissue stiffness. In simulation, fibroglandular content and deformation magnitude were shown to have significant effects on the shape and convexity of the objective function defined by image similarity. These observations provide an important step forward in characterizing the use of nonrigid image registration methodologies in conjunction with biomechanical models to estimate tissue stiffness. In addition, the results suggest that stiffness estimation methods using gravity-induced excitation can reliably and feasibly be implemented in breast cancer surgery/intervention workflows.
Youk, Ji Hyun; Jung, Inkyung; Yoon, Jung Hyun; Kim, Sung Hun; Kim, You Me; Lee, Eun Hye; Jeong, Sun Hye; Kim, Min Jung
2016-09-01
Our aim was to compare the inter-observer variability and diagnostic performance of the Breast Imaging Reporting and Data System (BI-RADS) lexicon for breast ultrasound of static and video images. Ninety-nine breast masses visible on ultrasound examination from 95 women 19-81 y of age at five institutions were enrolled in this study. They were scheduled to undergo biopsy or surgery or had been stable for at least 2 y of ultrasound follow-up after benign biopsy results or typically benign findings. For each mass, representative long- and short-axis static ultrasound images were acquired; real-time long- and short-axis B-mode video images through the mass area were separately saved as cine clips. Each image was reviewed independently by five radiologists who were asked to classify ultrasound features according to the fifth edition of the BI-RADS lexicon. Inter-observer variability was assessed using kappa (κ) statistics. Diagnostic performance on static and video images was compared using the area under the receiver operating characteristic curve. No significant difference was found in κ values between static and video images for all descriptors, although κ values of video images were higher than those of static images for shape, orientation, margin and calcifications. After receiver operating characteristic curve analysis, the video images (0.83, range: 0.77-0.87) had higher areas under the curve than the static images (0.80, range: 0.75-0.83; p = 0.08). Inter-observer variability and diagnostic performance of video images was similar to that of static images on breast ultrasonography according to the new edition of BI-RADS. Copyright © 2016 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.
Manning, Mark; Purrington, Kristen; Penner, Louis; Duric, Neb; Albrecht, Terrance L
2016-06-01
Some US states have mandated that women be informed when they have dense breasts; however, little is known about how general knowledge about breast density (BD) affects related health decision-making. We examined the effects of BD information and imaging technology information on 138 African-American (AA) and European-American (EA) women's intentions to discuss breast cancer screening with their physicians. Women were randomly assigned to receive BD information and/or imaging technology information via 2 by 2 factorial design, and completed planned behavior measures (e.g., attitudes, intentions) related to BC screening. Attitudes mediated the effects of BD information, and the mediation was stronger for AA women compared to EA women. Effects were more robust for BD information compared to imaging technology information. Results of moderator analyses revealed suppressor effects of injunctive norms that were moderated by imaging technology information. Information about BD favorably influences women's intentions to engage in relevant breast health behaviors. Stronger attitude mediated-effects for AA women suggest greater scrutiny of BD information. Since BD information may influence women's intentions to discuss BC screening, strategies to effectively present BD information to AA women should be investigated given the likelihood of their increased scrutiny of BD information. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Wang, Yu; Helminen, Emily; Jiang, Jingfeng
2015-09-01
Quasistatic ultrasound elastography (QUE) is being used to augment in vivo characterization of breast lesions. Results from early clinical trials indicated that there was a lack of confidence in image interpretation. Such confidence can only be gained through rigorous imaging tests using complex, heterogeneous but known media. The objective of this study is to build a virtual breast QUE simulation platform in the public domain that can be used not only for innovative QUE research but also for rigorous imaging tests. The main thrust of this work is to streamline biomedical ultrasound simulations by leveraging existing open source software packages including Field II (ultrasound simulator), VTK (geometrical visualization and processing), FEBio [finite element (FE) analysis], and Tetgen (mesh generator). However, integration of these open source packages is nontrivial and requires interdisciplinary knowledge. In the first step, a virtual breast model containing complex anatomical geometries was created through a novel combination of image-based landmark structures and randomly distributed (small) structures. Image-based landmark structures were based on data from the NIH Visible Human Project. Subsequently, an unstructured FE-mesh was created by Tetgen. In the second step, randomly positioned point scatterers were placed within the meshed breast model through an octree-based algorithm to make a virtual breast ultrasound phantom. In the third step, an ultrasound simulator (Field II) was used to interrogate the virtual breast phantom to obtain simulated ultrasound echo data. Of note, tissue deformation generated using a FE-simulator (FEBio) was the basis of deforming the original virtual breast phantom in order to obtain the postdeformation breast phantom for subsequent ultrasound simulations. Using the procedures described above, a full cycle of QUE simulations involving complex and highly heterogeneous virtual breast phantoms can be accomplished for the first time. Representative examples were used to demonstrate capabilities of this virtual simulation platform. In the first set of three ultrasound simulation examples, three heterogeneous volumes of interest were selected from a virtual breast ultrasound phantom to perform sophisticated ultrasound simulations. These resultant B-mode images realistically represented the underlying complex but known media. In the second set of three QUE examples, advanced applications in QUE were simulated. The first QUE example was to show breast tumors with complex shapes and/or compositions. The resultant strain images showed complex patterns that were normally seen in freehand clinical ultrasound data. The second and third QUE examples demonstrated (deformation-dependent) nonlinear strain imaging and time-dependent strain imaging, respectively. The proposed virtual QUE platform was implemented and successfully tested in this study. Through show-case examples, the proposed work has demonstrated its capabilities of creating sophisticated QUE data in a way that cannot be done through the manufacture of physical tissue-mimicking phantoms and other software. This open software architecture will soon be made available in the public domain and can be readily adapted to meet specific needs of different research groups to drive innovations in QUE.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quinn, Alexandra, E-mail: Alexandra.quinn@health.nsw.gov.au; Centre for Medical Radiation Physics, University of Wollongong, NSW; Liverpool and Macarthur Cancer Therapy Centres, NSW
2014-07-01
The purpose of this study was to investigate the delivered dose from a kilovoltage cone-beam computed tomography (kV-CBCT) acquired in breast treatment position for a left and right breast setup. The dose was measured with thermoluminescent dosimeters positioned within a female anthropomorphic phantom at organ locations. Imaging was performed on an Elekta Synergy XVI system with the phantom setup on a breast board. The image protocol involved 120 kVp, 140 mAs, and a 270° arc rotation clockwise 0° to 270° for the left breast setup and 270° to 180° for the right breast setup (maximum arc rotations possible). The dosemore » delivered to the left breast, right breast, and heart was 5.1 mGy, 3.9 mGy, and 4.0 mGy for the left breast setup kV-CBCT, and 6.4 mGy, 6.0 mGy, and 4.8 mGy for the right breast setup kV-CBCT, respectively. The rotation arc of the kV-CBCT influenced the dose delivered, with the right breast setup kV-CBCT found to deliver a dose of up to 4 mGy or 105% higher to the treated breast′s surface in comparison with the left breast setup. This is attributed to the kV-CBCT source being more proximal to the anterior of the phantom for a right breast setup, whereas the source is more proximal to the posterior of the patient for a left-side scan.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu Xinming; Lai Chaojen; Whitman, Gary J.
Purpose: The scan equalization digital mammography (SEDM) technique combines slot scanning and exposure equalization to improve low-contrast performance of digital mammography in dense tissue areas. In this study, full-field digital mammography (FFDM) images of an anthropomorphic breast phantom acquired with an anti-scatter grid at various exposure levels were superimposed to simulate SEDM images and investigate the improvement of low-contrast performance as quantified by primary signal-to-noise ratios (PSNRs). Methods: We imaged an anthropomorphic breast phantom (Gammex 169 ''Rachel,'' Gammex RMI, Middleton, WI) at various exposure levels using a FFDM system (Senographe 2000D, GE Medical Systems, Milwaukee, WI). The exposure equalization factorsmore » were computed based on a standard FFDM image acquired in the automatic exposure control (AEC) mode. The equalized image was simulated and constructed by superimposing a selected set of FFDM images acquired at 2, 1, 1/2, 1/4, 1/8, 1/16, and 1/32 times of exposure levels to the standard AEC timed technique (125 mAs) using the equalization factors computed for each region. Finally, the equalized image was renormalized regionally with the exposure equalization factors to result in an appearance similar to that with standard digital mammography. Two sets of FFDM images were acquired to allow for two identically, but independently, formed equalized images to be subtracted from each other to estimate the noise levels. Similarly, two identically but independently acquired standard FFDM images were subtracted to estimate the noise levels. Corrections were applied to remove the excess system noise accumulated during image superimposition in forming the equalized image. PSNRs over the compressed area of breast phantom were computed and used to quantitatively study the effects of exposure equalization on low-contrast performance in digital mammography. Results: We found that the highest achievable PSNR improvement factor was 1.89 for the anthropomorphic breast phantom used in this study. The overall PSNRs were measured to be 79.6 for the FFDM imaging and 107.6 for the simulated SEDM imaging on average in the compressed area of breast phantom, resulting in an average improvement of PSNR by {approx}35% with exposure equalization. We also found that the PSNRs appeared to be largely uniform with exposure equalization, and the standard deviations of PSNRs were estimated to be 10.3 and 7.9 for the FFDM imaging and the simulated SEDM imaging, respectively. The average glandular dose for SEDM was estimated to be 212.5 mrad, {approx}34% lower than that of standard AEC-timed FFDM (323.8 mrad) as a result of exposure equalization for the entire breast phantom. Conclusions: Exposure equalization was found to substantially improve image PSNRs in dense tissue regions and result in more uniform image PSNRs. This improvement may lead to better low-contrast performance in detecting and visualizing soft tissue masses and micro-calcifications in dense tissue areas for breast imaging tasks.« less
NASA Astrophysics Data System (ADS)
Wen, Gezheng; Park, Subok; Markey, Mia K.
2017-03-01
Multifocal and multicentric breast cancer (MFMC), i.e., the presence of two or more tumor foci within the same breast, has an immense clinical impact on treatment planning and survival outcomes. Detecting multiple breast tumors is challenging as MFMC breast cancer is relatively uncommon, and human observers do not know the number or locations of tumors a priori. Digital breast tomosynthesis (DBT), in which an x-ray beam sweeps over a limited angular range across the breast, has the potential to improve the detection of multiple tumors.1, 2 However, prior efforts to optimize DBT image quality only considered unifocal breast cancers (e.g.,3-9), so the recommended geometries may not necessarily yield images that are informative for the task of detecting MFMC. Hence, the goal of this study is to employ a 3D multi-lesion (ml) channelized-Hotelling observer (CHO) to identify optimal DBT acquisition geometries for MFMC. Digital breast phantoms and simulated DBT scanners of different geometries (e.g., wide or narrow arc scans, different number of projections in each scan) were used to generate image data for the simulation study. Multiple 3D synthetic lesions were inserted into different breast regions to simulate MF cases and MC cases. 3D partial least squares (PLS) channels, and 3D Laguerre-Gauss (LG) channels were estimated to capture discriminant information and correlations among signals in locally varying anatomical backgrounds, enabling the model observer to make both image-level and location-specific detection decisions. The 3D ml-CHO with PLS channels outperformed that with LG channels in this study. The simulated MC cases and MC cases were not equally difficult for the ml-CHO to detect across the different simulated DBT geometries considered in this analysis. Also, the results suggest that the optimal design of DBT may vary as the task of clinical interest changes, e.g., a geometry that is better for finding at least one lesion may be worse for counting the number of lesions.
Detection of masses in mammogram images using CNN, geostatistic functions and SVM.
Sampaio, Wener Borges; Diniz, Edgar Moraes; Silva, Aristófanes Corrêa; de Paiva, Anselmo Cardoso; Gattass, Marcelo
2011-08-01
Breast cancer occurs with high frequency among the world's population and its effects impact the patients' perception of their own sexuality and their very personal image. This work presents a computational methodology that helps specialists detect breast masses in mammogram images. The first stage of the methodology aims to improve the mammogram image. This stage consists in removing objects outside the breast, reducing noise and highlighting the internal structures of the breast. Next, cellular neural networks are used to segment the regions that might contain masses. These regions have their shapes analyzed through shape descriptors (eccentricity, circularity, density, circular disproportion and circular density) and their textures analyzed through geostatistic functions (Ripley's K function and Moran's and Geary's indexes). Support vector machines are used to classify the candidate regions as masses or non-masses, with sensitivity of 80%, rates of 0.84 false positives per image and 0.2 false negatives per image, and an area under the ROC curve of 0.87. Copyright © 2011 Elsevier Ltd. All rights reserved.
Dynamic contrast-enhanced breast MRI at 7 Tesla utilizing a single-loop coil: a feasibility trial.
Umutlu, Lale; Maderwald, Stefan; Kraff, Oliver; Theysohn, Jens M; Kuemmel, Sherko; Hauth, Elke A; Forsting, Michael; Antoch, Gerald; Ladd, Mark E; Quick, Harald H; Lauenstein, Thomas C
2010-08-01
The aim of this study was to assess the feasibility of dynamic contrast-enhanced ultra-high-field breast imaging at 7 Tesla. A total of 15 subjects, including 5 patients with histologically proven breast cancer, were examined on a 7 Tesla whole-body magnetic resonance imaging system using a unilateral linearly polarized single-loop coil. Subjects were placed in prone position on a biopsy support system, with the coil placed directly below the region of interest. The examination protocol included the following sequences: 1) T2-weighted turbo spin echo sequence; 2) six dynamic T1-weighted spoiled gradient-echo sequences; and 3) subtraction imaging. Contrast-enhanced T1-weighted imaging at 7 Tesla could be obtained at high spatial resolution with short acquisition times, providing good image accuracy and a conclusively good delineation of small anatomical and pathological structures. T2-weighted imaging could be obtained with high spatial resolution at adequate acquisition times. Because of coil limitations, four high-field magnetic resonance examinations showed decreased diagnostic value. This first scientific approach of dynamic contrast-enhanced breast magnetic resonance imaging at 7 Tesla demonstrates the complexity of ultra-high-field breast magnetic resonance imaging and countenances the implementation of further advanced bilateral coil concepts to circumvent current limitations from the coil and ultra-high-field magnetic strength. 2010 AUR. Published by Elsevier Inc. All rights reserved.
Karnan, M; Thangavel, K
2007-07-01
The presence of microcalcifications in breast tissue is one of the most incident signs considered by radiologist for an early diagnosis of breast cancer, which is one of the most common forms of cancer among women. In this paper, the Genetic Algorithm (GA) is proposed for automatic look at commonly prone area the breast border and nipple position to discover the suspicious regions on digital mammograms based on asymmetries between left and right breast image. The basic idea of the asymmetry approach is to scan left and right images are subtracted to extract the suspicious region. The proposed system consists of two steps: First, the mammogram images are enhanced using median filter, normalize the image, at the pectoral muscle region is excluding the border of the mammogram and comparing for both left and right images from the binary image. Further GA is applied to magnify the detected border. The figure of merit is calculated to evaluate whether the detected border is exact or not. And the nipple position is identified using GA. The some comparisons method is adopted for detection of suspected area. Second, using the border points and nipple position as the reference the mammogram images are aligned and subtracted to extract the suspicious region. The algorithms are tested on 114 abnormal digitized mammograms from Mammogram Image Analysis Society database.
Kim, Yun Ju; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo
2014-01-01
Objective The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Materials and Methods Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. Results The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Conclusion Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast. PMID:25053898
Clinical photoacoustic computed tomography of the human breast in vivo within a single breath hold
NASA Astrophysics Data System (ADS)
Lin, Li; Hu, Peng; Shi, Junhui; Appleton, Catherine M.; Maslov, Konstantin; Wang, Lihong V.
2018-03-01
We have developed a single-breath-hold photoacoustic computed tomography (SBH-PACT) system to detect tumors and reveal detailed angiographic information about human breasts. SBH-PACT provides high spatial and temporal resolutions with a deep in vivo penetration depth of over 4 cm. A volumetric breast image can be acquired by scanning the breast within a single breath hold ( 15 sec). We imaged a healthy female volunteer and seven breast cancer patients. SBH-PACT clearly identified all tumors by revealing higher blood vessel densities and lower compliance associated with the tumors
2009-07-01
detection, and management of breast cancer today. A variety of imaging methods including screening and diagnostic x- ray mammography and resonance...profile of a tumor. In addition, techniques such as x- ray imaging and MRI are not able to detect small early cancers or pre-cancerous breast...227 (2007). 18. S. Oldenburg , J. Jackson, S. Westcott, and N. Halas, “Infrared extinction properties of gold nanoshells,” Appl. Phys. Lett. 75, 2897
NASA Astrophysics Data System (ADS)
André, M. P.; Galperin, M.; Berry, A.; Ojeda-Fournier, H.; O'Boyle, M.; Olson, L.; Comstock, C.; Taylor, A.; Ledgerwood, M.
Our computer-aided diagnostic (CADx) tool uses advanced image processing and artificial intelligence to analyze findings on breast sonography images. The goal is to standardize reporting of such findings using well-defined descriptors and to improve accuracy and reproducibility of interpretation of breast ultrasound by radiologists. This study examined several factors that may impact accuracy and reproducibility of the CADx software, which proved to be highly accurate and stabile over several operating conditions.
Salehi, Leila; Azmi, Reza
2014-07-01
Breast cancer continues to be a significant public health problem in the world. Early detection is the key for improving breast cancer prognosis. In this way, magnetic resonance imaging (MRI) is emerging as a powerful tool for the detection of breast cancer. Breast MRI presently has two major challenges. First, its specificity is relatively poor, and it detects many false positives (FPs). Second, the method involves acquiring several high-resolution image volumes before, during, and after the injection of a contrast agent. The large volume of data makes the task of interpretation by the radiologist both complex and time-consuming. These challenges have led to the development of the computer-aided detection systems to improve the efficiency and accuracy of the interpretation process. Detection of suspicious regions of interests (ROIs) is a critical preprocessing step in dynamic contrast-enhanced (DCE)-MRI data evaluation. In this regard, this paper introduces a new automatic method to detect the suspicious ROIs for breast DCE-MRI based on region growing. The results indicate that the proposed method is thoroughly able to identify suspicious regions (accuracy of 75.39 ± 3.37 on PIDER breast MRI dataset). Furthermore, the FP per image in this method is averagely 7.92, which shows considerable improvement comparing to other methods like ROI hunter.