Sample records for breath

  1. Voluntary control of breathing does not alter vagal modulation of heart rate

    NASA Technical Reports Server (NTRS)

    Patwardhan, A. R.; Evans, J. M.; Bruce, E. N.; Eckberg, D. L.; Knapp, C. F.

    1995-01-01

    Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.

  2. TR-BREATH: Time-Reversal Breathing Rate Estimation and Detection.

    PubMed

    Chen, Chen; Han, Yi; Chen, Yan; Lai, Hung-Quoc; Zhang, Feng; Wang, Beibei; Liu, K J Ray

    2018-03-01

    In this paper, we introduce TR-BREATH, a time-reversal (TR)-based contact-free breathing monitoring system. It is capable of breathing detection and multiperson breathing rate estimation within a short period of time using off-the-shelf WiFi devices. The proposed system exploits the channel state information (CSI) to capture the miniature variations in the environment caused by breathing. To magnify the CSI variations, TR-BREATH projects CSIs into the TR resonating strength (TRRS) feature space and analyzes the TRRS by the Root-MUSIC and affinity propagation algorithms. Extensive experiment results indoor demonstrate a perfect detection rate of breathing. With only 10 s of measurement, a mean accuracy of can be obtained for single-person breathing rate estimation under the non-line-of-sight (NLOS) scenario. Furthermore, it achieves a mean accuracy of in breathing rate estimation for a dozen people under the line-of-sight scenario and a mean accuracy of in breathing rate estimation of nine people under the NLOS scenario, both with 63 s of measurement. Moreover, TR-BREATH can estimate the number of people with an error around 1. We also demonstrate that TR-BREATH is robust against packet loss and motions. With the prevailing of WiFi, TR-BREATH can be applied for in-home and real-time breathing monitoring.

  3. Syllable-related breathing in infants in the second year of life.

    PubMed

    Parham, Douglas F; Buder, Eugene H; Oller, D Kimbrough; Boliek, Carol A

    2011-08-01

    This study explored whether breathing behaviors of infants within the 2nd year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Vocalizations and breathing kinematics of 9 infants between 53 and 90 weeks of age were recorded. A strict selection protocol was used to identify analyzable breath cycles. Syllables were categorized on the basis of consensus coding. Inspiratory and expiratory durations, excursions, and slopes were calculated for the 3 breath cycle types and were normalized using mean tidal breath measures. Tidal breathing cycles were significantly different from syllable-related cycles on all breathing measures. There were no significant differences between unarticulated syllable cycles and canonical syllable cycles, even after controlling for utterance duration and sound pressure level. Infants in the 2nd year of life exhibit clear differences between tidal breathing and speech-related breathing, but categorically distinct breath support for syllable types with varying articulatory demands was not evident in the present findings. Speech development introduces increasingly complex utterances, so older infants may produce detectable articulation-related adaptations of breathing kinematics. For younger infants, breath support may vary systematically among utterance types, due more to phonatory variations than to articulatory demands.

  4. Syllable-Related Breathing in Infants in the Second Year of Life

    PubMed Central

    Parham, Douglas F.; Buder, Eugene H.; Oller, D. Kimbrough; Boliek, Carol A.

    2010-01-01

    Purpose This study explored whether breathing behaviors of infants within the second year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Method Vocalizations and breathing kinematics of nine infants between 53 and 90 weeks of age were recorded. A strict selection protocol was used to identify analyzable breath cycles. Syllables were categorized based on consensus coding. Inspiratory and expiratory durations, excursions, and slopes were calculated for the three breath cycle types and normalized using mean tidal breath measures. Results Tidal breathing cycles were significantly different from syllable-related cycles on all breathing measures. There were no significant differences between unarticulated syllable cycles and canonical syllable cycles, even after controlling for utterance duration and sound pressure level. Conclusions Infants in the second year of life exhibit clear differences between tidal breathing and speech-related breathing, but categorically distinct breath support for syllable types with varying articulatory demands was not evident in the current findings. Speech development introduces increasingly complex utterances, so older infants may produce detectable articulation-related adaptations of breathing kinematics. For younger infants, breath support may vary systematically among utterance types, due more to phonatory variations than to articulatory demands. PMID:21173390

  5. Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique.

    PubMed

    Armstrong, Tess; Ly, Karrie V; Murthy, Smruthi; Ghahremani, Shahnaz; Kim, Grace Hyun J; Calkins, Kara L; Wu, Holden H

    2018-05-04

    In adults, noninvasive chemical shift encoded Cartesian magnetic resonance imaging (MRI) and single-voxel magnetic resonance (MR) spectroscopy (SVS) accurately quantify hepatic steatosis but require breath-holding. In children, especially young and sick children, breath-holding is often limited or not feasible. Sedation can facilitate breath-holding but is highly undesirable. For these reasons, there is a need to develop free-breathing MRI technology that accurately quantifies steatosis in all children. This study aimed to compare non-sedated free-breathing multi-echo 3-D stack-of-radial (radial) MRI versus standard breath-holding MRI and SVS techniques in a group of children for fat quantification with respect to image quality, accuracy and repeatability. Healthy children (n=10, median age [±interquartile range]: 10.9 [±3.3] years) and overweight children with nonalcoholic fatty liver disease (NAFLD) (n=9, median age: 15.2 [±3.2] years) were imaged at 3 Tesla using free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS. Acquisitions were performed twice to assess repeatability (within-subject mean difference, MD within ). Images and hepatic proton-density fat fraction (PDFF) maps were scored for image quality. Free-breathing and breath-holding PDFF were compared using linear regression (correlation coefficient, r and concordance correlation coefficient, ρ c ) and Bland-Altman analysis (mean difference). P<0.05 was considered significant. In patients with NAFLD, free-breathing radial MRI demonstrated significantly less motion artifacts compared to breath-holding Cartesian (P<0.05). Free-breathing radial PDFF demonstrated a linear relationship (P<0.001) versus breath-holding SVS PDFF and breath-holding Cartesian PDFF with r=0.996 and ρ c =0.994, and r=0.997 and ρ c =0.995, respectively. The mean difference in PDFF between free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS was <0.7%. Repeated free-breathing radial MRI had MD within =0.25% for PDFF. In this pediatric study, non-sedated free-breathing radial MRI provided accurate and repeatable hepatic PDFF measurements and improved image quality, compared to standard breath-holding MR techniques.

  6. Breathing efficiency during inspiratory threshold loading in patients with chronic obstructive pulmonary disease.

    PubMed

    Baarends, E M; Schols, A M; Nusmeier, C M; van der Grinten, C P; Wouters, E F

    1998-05-01

    Patients with chronic obstructive pulmonary disease (COPD) demonstrate an increased oxygen cost of breathing. It is as yet unclear whether this is related to a decreased breathing efficiency. The aim of the present study was to compare breathing efficiency in 16 patients with COPD (11 men, five women) and 16 healthy elderly subjects (seven men, nine women), and to investigate a possible relationship between breathing efficiency and resting energy expenditure (REE). REE was measured using a ventilated hood system. Breathing efficiency was assessed by measuring oxygen consumption (V'O2), mean inspiratory mouth pressure (MIP) and flow during breathing at rest and subsequently during breathing against an inspiratory threshold (40% of maximal inspiratory pressure). During loaded breathing there was a significant increase in V'O2, MIP, and external work of breathing compared with unloaded breathing in both groups. As intended, ventilation did not increase significantly during the breathing efficiency test in the patients with COPD. The breathing efficiency (median, range) of the patients with COPD was similar (3.7%, 1.4-8.7%) to that of the healthy elderly subjects (3.2%, 1.7-8.3%). Breathing efficiency was not correlated with REE in either group. In the present study, in which dynamic hyperinflation was probably prevented, no difference in breathing efficiency was found between healthy elderly subjects and COPD patients when breathing against an external inspiratory threshold. Furthermore, breathing efficiency was not related to REE in both groups.

  7. Dosimetric comparison of moderate deep inspiration breath-hold and free-breathing intensity-modulated radiotherapy for left-sided breast cancer.

    PubMed

    Chi, F; Wu, S; Zhou, J; Li, F; Sun, J; Lin, Q; Lin, H; Guan, X; He, Z

    2015-05-01

    This study determined the dosimetric comparison of moderate deep inspiration breath-hold using active breathing control and free-breathing intensity-modulated radiotherapy (IMRT) after breast-conserving surgery for left-sided breast cancer. Thirty-one patients were enrolled. One free breathe and two moderate deep inspiration breath-hold images were obtained. A field-in-field-IMRT free-breathing plan and two field-in-field-IMRT moderate deep inspiration breath-holding plans were compared in the dosimetry to target volume coverage of the glandular breast tissue and organs at risks for each patient. The breath-holding time under moderate deep inspiration extended significantly after breathing training (P<0.05). There was no significant difference between the free-breathing and moderate deep inspiration breath-holding in the target volume coverage. The volume of the ipsilateral lung in the free-breathing technique were significantly smaller than the moderate deep inspiration breath-holding techniques (P<0.05); however, there was no significant difference between the two moderate deep inspiration breath-holding plans. There were no significant differences in target volume coverage between the three plans for the field-in-field-IMRT (all P>0.05). The dose to ipsilateral lung, coronary artery and heart in the field-in-field-IMRT were significantly lower for the free-breathing plan than for the two moderate deep inspiration breath-holding plans (all P<0.05); however, there was no significant difference between the two moderate deep inspiration breath-holding plans. The whole-breast field-in-field-IMRT under moderate deep inspiration breath-hold with active breathing control after breast-conserving surgery in left-sided breast cancer can reduce the irradiation volume and dose to organs at risks. There are no significant differences between various moderate deep inspiration breath-holding states in the dosimetry of irradiation to the field-in-field-IMRT target volume coverage and organs at risks. Copyright © 2015 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  8. Bronchiolitis

    MedlinePlus

    ... the child tries to breathe in (called intercostal retractions ) Infant's nostrils get wide when breathing Rapid breathing ( ... Has difficulty breathing Has nostril flarings or chest retractions when trying to breathe

  9. Recovery of Percent Vital Capacity by Breathing Training in Patients With Panic Disorder and Impaired Diaphragmatic Breathing.

    PubMed

    Yamada, Tatsuji; Inoue, Akiomi; Mafune, Kosuke; Hiro, Hisanori; Nagata, Shoji

    2017-09-01

    Slow diaphragmatic breathing is one of the therapeutic methods used in behavioral therapy for panic disorder. In practice, we have noticed that some of these patients could not perform diaphragmatic breathing and their percent vital capacity was initially reduced but could be recovered through breathing training. We conducted a comparative study with healthy controls to investigate the relationship between diaphragmatic breathing ability and percent vital capacity in patients with panic disorder. Our findings suggest that percent vital capacity in patients with impaired diaphragmatic breathing was significantly reduced compared with those with normal diaphragmatic breathing and that diaphragmatic breathing could be restored by breathing training. Percent vital capacity of the healthy controls was equivalent to that of the patients who had completed breathing training. This article provides preliminary findings regarding reduced vital capacity in relation to abnormal respiratory movements found in patients with panic disorder, potentially offering alternative perspectives for verifying the significance of breathing training for panic disorder.

  10. The role of arterial chemoreceptors in the breath-by-breath augmentation of inspiratory effort in rabbits during airway occlusion or elastic loading.

    PubMed

    Callanan, D; Read, D J

    1974-08-01

    1. The breath-by-breath augmentation of inspiratory effort in the five breaths following airway occlusion or elastic loading was assessed in anaesthetized rabbits from changes of airway pressure, diaphragm e.m.g. and lung volume.2. When the airway was occluded in animals breathing air, arterial O(2) tension fell by 20 mmHg and CO(2) tension rose by 7 mmHg within the time of the first five loaded breaths.3. Inhalation of 100% O(2) or carotid denervation markedly reduced the breath-by-breath progression but had little or no effect on the responses at the first loaded breath.4. These results indicate that the breath-by-breath augmentation of inspiratory effort following addition of a load is mainly due to asphyxial stimulation of the carotid bodies, rather than to the gradual emergence of a powerful load-compensating reflex originating in the chest-wall, as postulated by some workers.5. The small residual progression seen in animals breathing 100% O(2) or following carotid denervation was not eliminated (a) by combining these procedures or (b) by addition of gas to the lungs to prevent the progressive lung deflation which occurred during airway occlusion.6. Bilateral vagotomy, when combined with carotid denervation, abolished the residual breath-by-breath progression of inspiratory effort.

  11. Outcome of breath tests in adult patients with suspected small intestinal bacterial overgrowth

    PubMed Central

    Mattsson, Johanna; Minaya, Maria Teresa; Monegro, Milka; Lebwohl, Benjamin; Lewis, Suzanne K.; Green, Peter HR; Stenberg, Reidun

    2017-01-01

    Aim: The aim was to investigate breath test outcomes in patients with suspected SIBO and indicative symptoms of SIBO, diagnosed by breath testing. Background: Breath testing is used to detect small intestinal bacterial overgrowth (SIBO) by measuring hydrogen and methane produced by intestinal bacteria. Methods: This retrospective cross sectional study included 311 patients with gastrointestinal symptoms who underwent the breath test for evaluation of SIBO at Celiac Disease Center at Columbia University, New York, in 2014-2015. The patients were divided into two groups based on the physician’s choice: lactulose breath test group (72%) and glucose breath test group (28%). Among them, 38% had a history of celiac disease or non-celiac gluten sensitivity. Results: In total, 46% had a positive breath test: 18% were positive for methane, 24 % positive for hydrogen and 4% positive for both gases (p=0.014). Also, 50% had a positive lactulose breath result and 37% had a positive glucose breath result (p=0.036). The most common symptom for performing the breath test was bloating and the only clinical symptom that significantly showed a positive glucose breath test was increased gas (p=0.028). Conclusion: Lactulose breath test was more often positive than glucose breath test. Positivity for hydrogen was more common than methane. Bloating was the most frequently perceived symptom of the patients undergoing the breath test but the only statistically significant clinical symptom for a positive glucose breath test was increased gas. Furthermore, the results showed that there was no significant association between positive breath test result and gender, age, non-celiac gluten sensitivity or celiac disease. PMID:29118931

  12. Sensing the effects of mouth breathing by using 3-tesla MRI

    NASA Astrophysics Data System (ADS)

    Park, Chan-A.; Kang, Chang-Ki

    2017-06-01

    We investigated the effects of mouth breathing and typical nasal breathing on brain function by using blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging (fMRI). The study had two parts: the first test was a simple contrast between mouth and nasal breathing, and the second test involved combined breathing modes, e.g., mouth inspiration and nasal expiration. Eleven healthy participants performed the combined breathing task while undergoing 3T fMRI. In the group-level analysis, contrast images acquired by using an individual participantlevel analysis were processed using the one-sample t test. We also conducted a region-of-interest analysis comparing signal intensity changes between the breathing modes; the region was selected using an automated anatomical labeling map. The results demonstrated that the BOLD signal in the hippocampus and brainstem was significantly decreased in mouth breathing relative to nasal breathing. On the other hand, both the precentral and postcentral gyri showed activation that was more significant in mouth breathing compared to nasal breathing. This study suggests that the BOLD activity patterns between mouth and nasal breathing may be induced differently, especially in the hippocampus, which could provide clues to explain the effects on brain cognitive function due to mouth breathing.

  13. Application of LaserBreath-001 for breath acetone measurement in subjects with diabetes mellitus

    NASA Astrophysics Data System (ADS)

    Wang, Zhennan; Sun, Meixiu; Chen, Zhuying; Zhao, Xiaomeng; Li, Yingxin; Wang, Chuji

    2016-11-01

    Breath acetone is a promising biomarker of diabetes mellitus. With an integrated standalone, on-site cavity ringdown breath acetone analyzer, LaserBreath-001, we tested breath samples from 23 type 1 diabetic (T1D) patients, 312 type 2 diabetic (T2D) patients, 52 healthy subjects. In the cross-sectional studies, the obtained breath acetone concentrations were higher in the diabetic subjects compared with those in the control group. No correlation between breath acetone and simultaneous BG was observed in the T1D, T2D, and healthy subjects. A moderate positive correlation between the mean individual breath acetone concentrations and the mean individual BG levels was observed in the 20 T1D patients without ketoacidosis. In a longitudinal study, the breath acetone concentrations in a T1D patient with ketoacidosis decreased significantly and remained stable during the 5-day hospitalization. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone concentrations, fast (<1 min) and on site breath acetone measurement can be used for diabetic screening and management under a specifically controlled condition.

  14. Apnea of Prematurity (For Parents)

    MedlinePlus

    ... large bursts of breath followed by periods of shallow breathing or stopped breathing. Apnea of prematurity usually ... seconds and is followed by several fast and shallow breaths. Periodic breathing doesn't cause a change ...

  15. How to breathe when you are short of breath

    MedlinePlus

    ... pursed lip breathing; Hypoxia - pursed lip breathing; Chronic respiratory failure - pursed lip breathing ... et al, eds. Murray and Nadel's Textbook of Respiratory Medicine . 6th ed. Philadelphia, PA: Elsevier Saunders; 2016: ...

  16. Controlled breathing protocols probe human autonomic cardiovascular rhythms

    NASA Technical Reports Server (NTRS)

    Cooke, W. H.; Cox, J. F.; Diedrich, A. M.; Taylor, J. A.; Beightol, L. A.; Ames, J. E. 4th; Hoag, J. B.; Seidel, H.; Eckberg, D. L.

    1998-01-01

    The purpose of this study was to determine how breathing protocols requiring varying degrees of control affect cardiovascular dynamics. We measured inspiratory volume, end-tidal CO2, R-R interval, and arterial pressure spectral power in 10 volunteers who followed the following 5 breathing protocols: 1) uncontrolled breathing for 5 min; 2) stepwise frequency breathing (at 0.3, 0.25, 0.2, 0.15, 0.1, and 0.05 Hz for 2 min each); 3) stepwise frequency breathing as above, but with prescribed tidal volumes; 4) random-frequency breathing (approximately 0.5-0.05 Hz) for 6 min; and 5) fixed-frequency breathing (0.25 Hz) for 5 min. During stepwise breathing, R-R interval and arterial pressure spectral power increased as breathing frequency decreased. Control of inspired volume reduced R-R interval spectral power during 0.1 Hz breathing (P < 0.05). Stepwise and random-breathing protocols yielded comparable coherence and transfer functions between respiration and R-R intervals and systolic pressure and R-R intervals. Random- and fixed-frequency breathing reduced end-tidal CO2 modestly (P < 0.05). Our data suggest that stringent tidal volume control attenuates low-frequency R-R interval oscillations and that fixed- and random-rate breathing may decrease CO2 chemoreceptor stimulation. We conclude that autonomic rhythms measured during different breathing protocols have much in common but that a stepwise protocol without stringent control of inspired volume may allow for the most efficient assessment of short-term respiratory-mediated autonomic oscillations.

  17. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  18. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  19. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  20. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  1. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  2. Reduction in respiratory motion artefacts on gadoxetate-enhanced MRI after training technicians to apply a simple and more patient-adapted breathing command.

    PubMed

    Gutzeit, Andreas; Matoori, Simon; Froehlich, Johannes M; von Weymarn, Constantin; Reischauer, Carolin; Kolokythas, Orpheus; Goyen, Matthias; Hergan, Klaus; Meissnitzer, Matthias; Forstner, Rosemarie; Soyka, Jan D; Doert, Aleksis; Koh, Dow-Mu

    2016-08-01

    To investigate whether a trained group of technicians using a modified breathing command during gadoxetate-enhanced liver MRI reduces respiratory motion artefacts compared to non-trained technicians using a traditional breathing command. The gadoxetate-enhanced liver MR images of 30 patients acquired using the traditional breathing command and the subsequent 30 patients after training the technicians to use a modified breathing command were analyzed. A subgroup of patients (n = 8) underwent scans both by trained and untrained technicians. Images obtained using the traditional and modified breathing command were compared for the presence of breathing artefacts [respiratory artefact-based image quality scores from 1 (best) to 5 (non-diagnostic)]. There was a highly significant improvement in the arterial phase image quality scores in patients using the modified breathing command compared to the traditional one (P < 0.001). The percentage of patients with severe and extensive breathing artefacts in the arterial phase decreased from 33.3 % to 6.7 % after introducing the modified breathing command (P = 0.021). In the subgroup that underwent MRI using both breathing commands, arterial phase image quality improved significantly (P = 0.008) using the modified breathing command. Training technicians to use a modified breathing command significantly improved arterial phase image quality of gadoxetate-enhanced liver MRI. • A modified breathing command reduced respiratory artefacts on arterial-phase gadoxetate-enhanced MRI (P < 0.001). • The modified command decreased severe and extensive arterial-phase breathing artefacts (P = 0.021). • Training technicians to use a modified breathing command improved arterial-phase images.

  3. A Gaussian method to improve work-of-breathing calculations.

    PubMed

    Petrini, M F; Evans, J N; Wall, M A; Norman, J R

    1995-01-01

    The work of breathing is a calculated index of pulmonary function in ventilated patients that may be useful in deciding when to wean and when to extubate. However, the accuracy of the calculated work of breathing of the patient (WOBp) can suffer from artifacts introduced by coughing, swallowing, and other non-breathing maneuvers. The WOBp in this case will include not only the usual work of inspiration, but also the work of performing these non-breathing maneuvers. The authors developed a method to objectively eliminate the calculated work of these movements from the work of breathing, based on fitting to a Gaussian curve the variable P, which is obtained from the difference between the esophageal pressure change and the airway pressure change during each breath. In spontaneously breathing adults the normal breaths fit the Gaussian curve, while breaths that contain non-breathing maneuvers do not. In this Gaussian breath-elimination method (GM), breaths that are two standard deviations from that mean obtained by the fit are eliminated. For normally breathing control adult subjects, GM had little effect on WOBp, reducing it from 0.49 to 0.47 J/L (n = 8), while there was a 40% reduction in the coefficient of variation. Non-breathing maneuvers were simulated by coughing, which increased WOBp to 0.88 (n = 6); with the GM correction, WOBp was 0.50 J/L, a value not significantly different from that of normal breathing. Occlusion also increased WOBp to 0.60 J/L, but GM-corrected WOBp was 0.51 J/L, a normal value. As predicted, doubling the respiratory rate did not change the WOBp before or after the GM correction.(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Intracyclic velocity variation and arm coordination assessment in swimmers with Down syndrome.

    PubMed

    Marques-Aleixo, Inês; Querido, Ana; Figueiredo, Pedro; Vilas-Boas, João Paulo; Corredeira, Rui; Daly, Daniel; Fernandes, Ricardo J

    2013-01-01

    This study examined the differences in intracycle velocity variation and arm coordination in front crawl in swimmers with Down syndrome in three breathing conditions. International swimmers with Down syndrome (N = 16) performed 3 × 20 m front crawl at 50 m race speed: without breathing, breathing to the preferred side, and breathing to the nonpreferred side. A two dimensional video movement analysis was performed using the APASystem. Breathing conditions were compared using Repeated Measures ANOVA. Swimming velocity was higher without breathing and intracyclic velocity variation was higher while breathing. Swimmers tended to a catch up arm coordination mode for both breathing conditions and a superposition mode when not breathing. These data reflect arm coordination compromising swimming performance, particularly when comparing with non disabled swimmers in literature. The physical and perhaps cognitive impairment associated with Down syndrome may result in a disadvantage in both propulsion and drag, more evident when breathing.

  5. Breath-collection device for delayed breath-alcohol analysis

    DOT National Transportation Integrated Search

    1980-12-01

    The report includes the details of a study to develop, evaluate, and validate a breath collection device (BCD) for delayed breath-alcohol analysis. Primary applications of the BCD include collection of breath-alcohol samples for field surveys or for ...

  6. A Pilot Study on the Effects of Slow Paced Breathing on Current Food Craving.

    PubMed

    Meule, Adrian; Kübler, Andrea

    2017-03-01

    Heart rate variability biofeedback (HRV-BF) involves slow paced breathing (approximately six breaths per minute), thereby maximizing low-frequent heart rate oscillations and baroreflex gain. Mounting evidence suggests that HRV-BF promotes symptom reductions in a variety of physical and mental disorders. It may also positively affect eating behavior by reducing food cravings. The aim of the current study was to investigate if slow paced breathing can be useful for attenuating momentary food craving. Female students performed paced breathing either at six breaths per minute (n = 32) or at nine breaths per minute (n = 33) while watching their favorite food on the computer screen. Current food craving decreased during a first resting period, increased during paced breathing, and decreased during a second resting period in both conditions. Although current hunger increased in both conditions during paced breathing as well, it remained elevated after the second resting period in the nine breaths condition only. Thus, breathing rate did not influence specific food craving, but slow paced breathing appeared to have a delayed influence on state hunger. Future avenues are suggested for the study of HRV-BF in the context of eating behavior.

  7. Optimising diffusion-weighted MR imaging for demonstrating pancreatic cancer: a comparison of respiratory-triggered, free-breathing and breath-hold techniques.

    PubMed

    Kartalis, Nikolaos; Loizou, Louiza; Edsborg, Nick; Segersvärd, Ralf; Albiin, Nils

    2012-10-01

    To compare respiratory-triggered, free-breathing, and breath-hold DWI techniques regarding (1) image quality, and (2) signal intensity (SI) and ADC measurements in pancreatic ductal adenocarcinoma (PDAC). Fifteen patients with histopathologically proven PDAC underwent DWI prospectively at 1.5 T (b = 0, 50, 300, 600 and 1,000 s/mm(2)) with the three techniques. Two radiologists, independently and blindly, assigned total image quality scores [sum of rating diffusion images (lesion detection, anatomy, presence of artefacts) and ADC maps (lesion characterisation, overall image quality)] per technique and ranked them. The lesion SI, signal-to-noise ratio, mean ADC and coefficient of variation (CV) were compared. Total image quality scores for respiratory-triggered, free-breathing and breath-hold techniques were 17.9, 16.5 and 17.1 respectively (respiratory-triggered was significantly higher than free-breathing but not breath-hold). The respiratory-triggered technique had a significantly higher ranking. Lesion SI on all b-values and signal-to-noise ratio on b300 and b600 were significantly higher for the respiratory-triggered technique. For respiratory-triggered, free-breathing and breath-hold techniques the mean ADCs were 1.201, 1.132 and 1.253 × 10(-3) mm(2)/s, and mean CVs were 8.9, 10.8 and 14.1 % respectively (respiratory-triggered and free-breathing techniques had a significantly lower mean CV than the breath-hold technique). In both analyses, respiratory-triggered DWI showed superiority and seems the optimal DWI technique for demonstrating PDAC. • Diffusion-weighted magnetic resonance imaging is increasingly used to detect pancreatic cancer • Images are acquired using various breathing techniques and multiple b-values • Breathing techniques used: respiratory-triggering, free-breathing and breath-hold • Respiratory-triggering seems the optimal breathing technique for demonstrating pancreatic cancer.

  8. Control of gill ventilation and air-breathing in the bowfin amia calva

    PubMed

    Hedrick; Jones

    1999-01-01

    The purpose of this study was to investigate the roles of branchial and gas bladder reflex pathways in the control of gill ventilation and air-breathing in the bowfin Amia calva. We have previously determined that bowfin use two distinct air-breathing mechanisms to ventilate the gas bladder: type I air breaths are characterized by exhalation followed by inhalation, are stimulated by aquatic or aerial hypoxia and appear to regulate O2 gas exchange; type II air breaths are characterized by inhalation alone and possibly regulate gas bladder volume and buoyancy. In the present study, we test the hypotheses (1) that gill ventilation and type I air breaths are controlled by O2-sensitive chemoreceptors located in the branchial region, and (2) that type II air breaths are controlled by gas bladder mechanosensitive stretch receptors. Hypothesis 1 was tested by examining the effects of partial or complete branchial denervation of cranial nerves IX and X to the gill arches on gill ventilation frequency (fg) and the proportion of type I air breaths during normoxia and hypoxia; hypothesis II was tested by gas bladder inflation and deflation. Following complete bilateral branchial denervation, fg did not differ from that of sham-operated control fish; in addition, fg was not significantly affected by aquatic hypoxia in sham-operated or denervated fish. In sham-operated fish, aquatic hypoxia significantly increased overall air-breathing frequency (fab) and the percentage of type I breaths. In fish with complete IX-X branchial denervation, fab was also significantly increased during aquatic hypoxia, but there were equal percentages of type I and type II air breaths. Branchial denervation did not affect the frequency of type I air breaths during aquatic hypoxia. Gas bladder deflation via an indwelling catheter resulted in type II breaths almost exclusively; furthermore, fab was significantly correlated with the volume removed from the gas bladder, suggesting a volume-regulating function for type II air breaths. These results indicate that chronic (3-4 weeks) branchial denervation does not significantly affect fg or type I air-breathing responses to aquatic hypoxia. Because type I air-breathing responses to aquatic hypoxia persist after IX-X cranial nerve denervation, O2-sensitive chemoreceptors that regulate air-breathing may be carried in other afferent pathways, such as the pseudobranch. Gas bladder deflation reflexly stimulates type II breaths, suggesting that gas bladder volume-sensitive stretch receptors control this particular air-breathing mechanism. It is likely that type II air breaths function to regulate buoyancy when gas bladder volume declines during the inter-breath interval.

  9. Timing of the breath analyzer: does it make a difference?

    PubMed

    Cherpitel, C J

    1993-09-01

    The purpose of this article is to examine in an emergency room (ER) population the concordance of self-reports of no alcohol consumption prior to injury with breath-analyzer readings in two groups: (1) those patients from whom reports were obtained after they were breath analyzed compared to (2) patients from whom reports were obtained prior to obtaining the breath-analyzer reading. Data were collected on a probability sample of patients attending three health maintenance organization ERs. Among those sampled were 159 patients admitted for initial treatment of an injury, who were breath analyzed within 6 hours of the event and reported no drinking following the event that lead to injury. Of these, 119 were breath analyzed prior to the interview, and none who reported not drinking were positive on the breath analyzer, while of the 37 breath analyzed after the interview, only one was positive who had reported not drinking. Obtaining the breath-analyzer reading following the interview was not found to affect the rate of refusal to provide a breath-analyzer reading; however, it was found to adversely affect obtaining the breath-analyzer reading for other reasons. The data suggest that the concordance of negative self-reports of consumption with breath-analyzer readings remains high in ER populations regardless of when the breath-analyzer reading is obtained; however, it appears best to obtain the reading prior to interviewing the patient for reasons explained below.

  10. Practice It: Deep Conscious Breathing Exercise

    Cancer.gov

    No time to sit and breathe? No problem; take your breathing practice with you! Deep conscious breathing can also be done with the eyes open wherever you happen to be—simply pause and take two to three full deep breaths (inhale deeply and exhale completely).

  11. SU-E-T-326: The Oxygen Saturation (SO2) and Breath-Holding Time Variation Applied Active Breathing Control (ABC)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, G; Yin, Y

    Purpose: To study the oxygen saturation (SO2) and breath-holding time variation applied active breathing control (ABC) in radiotherapy of tumor. Methods: 24 volunteers were involved in our trials, and they all did breath-holding motion assisted by ELEKTA Active Breathing Coordinator 2.0 for 10 times respectively. And the patient monitor was used to observe the oxygen saturation (SO2) variation. The variation of SO2, and length of breath-holding time and the time for recovering to the initial value of SO2 were recorded and analyzed. Results: (1) The volunteers were divided into two groups according to the SO2 variation in breath-holding: A group,more » 14 cases whose SO2 reduction were more than 2% (initial value was 97% to 99%, while termination value was 91% to 96%); B group, 10 cases were less than 2% in breath-holding without inhaling oxygen. (2) The interfraction breath holding time varied from 8 to 20s for A group compared to the first breath-holding time, and for B group varied from 4 to 14s. (3) The breathing holding time of B group prolonged mean 8s, compared to A group. (4) The time for restoring to the initial value of SO2 was from 10s to 30s. And the breath-holding time shortened obviously for patients whose SO2 did not recover to normal. Conclusion: It is very obvious that the SO2 reduction in breath-holding associated with ABC for partial people. It is necessary to check the SO2 variation in breath training, and enough time should be given to recover SO2.« less

  12. Breathing exercises for dysfunctional breathing/hyperventilation syndrome in adults.

    PubMed

    Jones, Mandy; Harvey, Alex; Marston, Louise; O'Connell, Neil E

    2013-05-31

    Dysfunctional breathing/hyperventilation syndrome (DB/HVS) is a respiratory disorder, psychologically or physiologically based, involving breathing too deeply and/or too rapidly (hyperventilation) or erratic breathing interspersed with breath-holding or sighing (DB). DB/HVS can result in significant patient morbidity and an array of symptoms including breathlessness, chest tightness, dizziness, tremor and paraesthesia. DB/HVS has an estimated prevalence of 9.5% in the general adult population, however, there is little consensus regarding the most effective management of this patient group. (1) To determine whether breathing exercises in patients with DB/HVS have beneficial effects as measured by quality of life indices (2) To determine whether there are any adverse effects of breathing exercises in patients with DB/HVS SEARCH METHODS: We identified trials for consideration using both electronic and manual search strategies. We searched CENTRAL, MEDLINE, EMBASE, and four other databases. The latest search was in February 2013. We planned to include randomised, quasi-randomised or cluster randomised controlled trials (RCTs) in which breathing exercises, or a combined intervention including breathing exercises as a key component, were compared with either no treatment or another therapy that did not include breathing exercises in patients with DB/HVS. Observational studies, case studies and studies utilising a cross-over design were not eligible for inclusion.We considered any type of breathing exercise for inclusion in this review, such as breathing control, diaphragmatic breathing, yoga breathing, Buteyko breathing, biofeedback-guided breathing modification, yawn/sigh suppression. Programs where exercises were either supervised or unsupervised were eligible as were relaxation techniques and acute-episode management, as long as it was clear that breathing exercises were a key component of the intervention.We excluded any intervention without breathing exercises or where breathing exercises were not key to the intervention. Two review authors independently checked search results for eligible studies, assessed all studies that appeared to meet the selection criteria and extracted data. We used standard procedures recommended by The Cochrane Collaboration. We included a single RCT assessed at unclear risk of bias, which compared relaxation therapy (n = 15) versus relaxation therapy and breathing exercises (n = 15) and a no therapy control group (n = 15).Quality of life was not an outcome measure in this RCT, and no numerical data or statistical analysis were presented in this paper. A significant reduction in the frequency and severity of hyperventilation attacks in the breathing exercise group compared with the control group was reported. In addition, a significant difference in frequency and severity of hyperventilation attacks between the breathing and relaxation group was reported. However, no information could be extracted from the paper regarding the size of the treatment effects. The results of this systematic review are unable to inform clinical practice, based on the inclusion of only one small, poorly reported RCT. There is no credible evidence regarding the effectiveness of breathing exercises for the clinical symptoms of DB/HVS. It is currently unknown whether these interventions offer any added value in this patient group or whether specific types of breathing exercise demonstrate superiority over others. Given that breathing exercises are frequently used to treat DB/HVS, there is an urgent need for further well designed clinical trials in this area. Future trials should conform to the CONSORT statement for standards of reporting and use appropriate, validated outcome measures. Trial reports should also ensure full disclosure of data for all important clinical outcomes.

  13. The effect of breath freshener strips on two types of breath alcohol testing instruments.

    PubMed

    Moore, Ronald L; Guillen, Jennifer

    2004-07-01

    The potential for breath freshener strips to interfere with the accuracy of a breath alcohol test was studied. Twelve varieties of breath freshener strips from five manufacturers were examined. Breath tests were conducted using the infrared based BAC DataMaster or the fuel cell based Alco-Sensor IV-XL, 30 and 150 seconds after placing a breath strip on the tongue. No effect was observed using the Alco-Sensor system. Some of the strips gave a small reading at 30 seconds (less than or equal to 0.010 g/210 L apparent alcohol) using the DataMaster. Readings on the DataMaster returned to zero by the 150 second test. A proper pre-test observation and deprivation period should prevent any interference from breath freshener strips on breath alcohol testing.

  14. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Self-contained breathing apparatus; description. 84...-Contained Breathing Apparatus § 84.70 Self-contained breathing apparatus; description. (a) Self-contained breathing apparatus, including all completely assembled, portable, self-contained devices designed for use...

  15. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Self-contained breathing apparatus; description. 84...-Contained Breathing Apparatus § 84.70 Self-contained breathing apparatus; description. (a) Self-contained breathing apparatus, including all completely assembled, portable, self-contained devices designed for use...

  16. Standardization of exhaled breath condensate (EBC) collection using a feedback regulated breathing pattern

    EPA Science Inventory

    Collection of exhaled breath condensate (EBC) fluid by cooling of expired breath is a potentially valuable approach for the detection of biomarkers associated with disease or exposure to xenobiotics. EBC is generally collected using unregulated breathing patterns, perceived to el...

  17. Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications

    PubMed Central

    Lourenço, Célia; Turner, Claire

    2014-01-01

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. “Breath fingerprinting”, indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles. PMID:24957037

  18. Breath analysis in disease diagnosis: methodological considerations and applications.

    PubMed

    Lourenço, Célia; Turner, Claire

    2014-06-20

    Breath analysis is a promising field with great potential for non-invasive diagnosis of a number of disease states. Analysis of the concentrations of volatile organic compounds (VOCs) in breath with an acceptable accuracy are assessed by means of using analytical techniques with high sensitivity, accuracy, precision, low response time, and low detection limit, which are desirable characteristics for the detection of VOCs in human breath. "Breath fingerprinting", indicative of a specific clinical status, relies on the use of multivariate statistics methods with powerful in-built algorithms. The need for standardisation of sample collection and analysis is the main issue concerning breath analysis, blocking the introduction of breath tests into clinical practice. This review describes recent scientific developments in basic research and clinical applications, namely issues concerning sampling and biochemistry, highlighting the diagnostic potential of breath analysis for disease diagnosis. Several considerations that need to be taken into account in breath analysis are documented here, including the growing need for metabolomics to deal with breath profiles.

  19. Calculating rhythmicity of infant breathing using wavelets

    NASA Astrophysics Data System (ADS)

    Macey, Katherine E.; Page, Wyatt H.; Harper, Ronald M.; Macey, Paul M.; Ford, Rodney P. K.

    2000-12-01

    Breathing signals are one set of physiological data that may provide information regarding the mechanisms that cause SIDS. Isolated breathing pauses have been implicated in fatal events. Other features of interest include slow amplitude modulation of the breathing signal, a phenomenon whose origin is unclear, and periodic breathing. The latter describes a repetitive series of apnea, and may be considered an extreme manifestation of amplitude modulation with successive cessations of breathing. Rhythmicity is defined to assess the impact of amplitude modulation on breathing signals and describes the extent to which frequency components remain constant for the duration of the signal. The wavelet transform was used to identify sections of constant frequency components within signals. Rhythmicity can be evaluated for all the frequency components in a signal, for individual frequencies. The rhythmicity of eight breathing epochs from sleeping infants at high and low risk for SIDS was calculated. Initial results show breathing from infants at high risk for SIDS exhibits greater rhythmicity of modulating frequencies than breathing from low risk infants.

  20. Abdominal organ motion during inhalation and exhalation breath-holds: pancreatic motion at different lung volumes compared.

    PubMed

    Lens, Eelco; Gurney-Champion, Oliver J; Tekelenburg, Daniël R; van Kesteren, Zdenko; Parkes, Michael J; van Tienhoven, Geertjan; Nederveen, Aart J; van der Horst, Astrid; Bel, Arjan

    2016-11-01

    Contrary to what is commonly assumed, organs continue to move during breath-holding. We investigated the influence of lung volume on motion magnitude during breath-holding and changes in velocity over the duration of breath-holding. Sixteen healthy subjects performed 60-second inhalation breath-holds in room-air, with lung volumes of ∼100% and ∼70% of the inspiratory capacity, and exhalation breath-holds, with lung volumes of ∼30% and ∼0% of the inspiratory capacity. During breath-holding, we obtained dynamic single-slice magnetic-resonance images with a time-resolution of 0.6s. We used 2-dimensional image correlation to obtain the diaphragmatic and pancreatic velocity and displacement during breath-holding. Organ velocity was largest in the inferior-superior direction and was greatest during the first 10s of breath-holding, with diaphragm velocities of 0.41mm/s, 0.29mm/s, 0.16mm/s and 0.15mm/s during BH 100% , BH 70% , BH 30% and BH 0% , respectively. Organ motion magnitudes were larger during inhalation breath-holds (diaphragm moved 9.8 and 9.0mm during BH 100% and BH 70% , respectively) than during exhalation breath-holds (5.6 and 4.3mm during BH 30% and BH 0% , respectively). Using exhalation breath-holds rather than inhalation breath-holds and delaying irradiation until after the first 10s of breath-holding may be advantageous for irradiation of abdominal tumors. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. A sigh of relief or a sigh to relieve: The psychological and physiological relief effect of deep breaths.

    PubMed

    Vlemincx, Elke; Van Diest, Ilse; Van den Bergh, Omer

    2016-10-15

    Both animal and human research have revealed important associations between sighs and relief. Previously we argued to conceive of sighs as resetters which temporarily induce relief. The present study aimed to investigate the psychological and physiological relief effect of sighs by instructed deep breaths and spontaneous sighs compared to a control breathing maneuver. Participants completed three blocks of 40 trials during which uncertainty cues were followed by either safety cues followed by a positive picture, or danger cues followed by a negative picture. One block was presented without breathing instructions, two subsequent blocks with breathing instructions. During the presentation of the safety and danger cues, an instruction was given to either 'take a deep breath' or 'postpone the next inhalation for 2 s (breath hold). Continuously, participants rated relief and Frontalis electromyography was recorded. Trait anxiety sensitivity was assessed by the Anxiety Sensitivity Index. Self-reported relief and physiological tension were compared 5s before and after instructed deep breaths and breath holds, and before and after spontaneous deep breaths and breath holds in the respective blocks. Results show that self-reported relief following an instructed deep breath was higher than before. Physiological tension decreased following a spontaneous sigh in high anxiety sensitive persons and following a spontaneous breath hold in low anxiety sensitive persons. These results are the first to show that a deep breath relieves and, in anxiety sensitive persons, reduces physiological tension. These findings support the hypothesis that sighs are psychological and physiological resetters. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. News from the Breath Analysis Summit 2011.

    PubMed

    Corradi, Massimo; Mutti, Antonio

    2012-06-01

    This special section highlights some of the important work presented at the Breath Analysis Summit 2011, which was held in Parma (Italy) from 11 to 14 September 2011. The meeting, which was jointly organized by the International Association for Breath Research and the University of Parma, was attended by more than 250 delegates from 33 countries, and offered 34 invited lectures and 64 unsolicited scientific contributions. The summit was organized to provide a forum to scientists, engineers and clinicians to present their latest findings and to meet industry executives and entrepreneurs to discuss key trends, future directions and technologies available for breath analysis. A major focus was on nitric oxide, exhaled breath condensate, electronic nose, mass spectrometry and newer sensor technologies. Medical applications ranged from asthma and other respiratory diseases to gastrointestinal disease, occupational diseases, critical care and cancer. Most people identify breath tests with breathalysers used by police to estimate ethanol concentration in blood. However, breath testing has far more sophisticated applications. Breath analysis is rapidly evolving as a new frontier in medical testing for disease states in the lung and beyond. Every individual has a breath fingerprint-or 'breathprint'-that can provide useful information about his or her state of health. This breathprint comprises the many thousands of molecules that are expelled with each breath we exhale. Breath research in the past few years has uncovered the scientific and molecular basis for such clinical observations. Relying on mass spectrometry, we have been able to identify many such unique substances in exhaled breath, including gases, such as nitric oxide (NO) and carbon monoxide (CO), and a wide array of volatile organic compounds. Exhaled breath also carries aerosolized droplets that can be collected as an exhaled breath condensate that contains endogenously produced non-volatile compounds. Breath analysis is now used to diagnose and monitor asthma, check for transplant organ rejection, detect lung cancer and test for Helicobacter pyloriinfection-and the list is growing. A major milestone in the scientific study of breath was marked in the 1970s when Linus Pauling demonstrated that there is more to exhaled breath than the classic gases of nitrogen, oxygen, carbon dioxide and water vapour-a lot more. Based on the gas-liquid partition chromatography analysis, Pauling reported the presence of 250 substances in exhaled breath. We now have the technology to test for any and all of these components. The field of breath analysis has made considerable advances in the 21st century and the utility of breath analysis in health care is advancing quickly. The science is rapidly expanding, the technology is improving and several new applications have been developed or are under commercial development. Breath analysis may rely on both direct (on line) and indirect (off line) reading methods: in the on-line method, breath analysis is immediately available, whereas the use of indirect methods generally involves collecting and trapping the breath sample and subsequently transferring it to an analytical instrument for analysis. Various kinds of breath samples have been used in biological monitoring, including mixed expired air and end expired air: end exhaled air represents the alveolar air concentration and mixed exhaled air represents the gas mixture coming from the dead space of the bronchial tree and the alveolar gas-exchange space. Exhaled breath analysis is an area where the modern day advances in technology and engineering meet the ever expanding need in medicine for more sensitive, specific and non-invasive tests which makes this area a major front in the interface between medicine and engineering. A major breakthrough over the past decade has been the increase in breath-based tests approved by the US Food and Drug Administration (FDA). Devices measuring common breath gases (oxygen, nitrogen, water vapour and CO(2)) in patient respiratory monitoring have served as a platform for technological growth in clinical breath-testing applications. A few exhaled breath tests have demonstrated clinical utility and are in widespread use, and several FDA-approved devices are available. These widely used exhaled breath tests include detection of blood alcohol concentration and exhaled CO(2). Other clinical applications of exhaled breath analysis include testing for H. pylori infection, lactose intolerance, heart transplant rejection and, more recently, monitoring of airway inflammation by means of exhaled NO. Examination of exhaled breath has the potential to change the existing routine approaches in human medicine. The rapidly developing new analytical and computer technologies along with novel, unorthodox ideas are prerequisites for future advances in this field. Scientists who participated in the Breath Analysis Summit 2011 were invited to submit a full length paper to the Journal of Breath Research and this issue includes eight articles which describe the different applications of breath analysis. We thank all the authors for their valuable contribution and we trust that this collection will provide useful information and an update to this rapidly evolving field, giving an example of integration among scientists who address the same topic-breath analysis-from different and complementary perspectives, from basic to clinical research.

  3. 46 CFR 197.456 - Breathing supply hoses.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Breathing supply hoses. 197.456 Section 197.456 Shipping....456 Breathing supply hoses. (a) The diving supervisor shall insure that— (1) Each breathing supply....5 times its maximum working pressure; (2) Each breathing supply hose assembly, prior to being placed...

  4. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS... 46 Shipping 3 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78...

  5. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Self-contained breathing apparatus; required...-Contained Breathing Apparatus § 84.71 Self-contained breathing apparatus; required components. (a) Each self-contained breathing apparatus described in § 84.70 shall, where its design requires, contain the following...

  6. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Self-contained breathing apparatus; required...-Contained Breathing Apparatus § 84.71 Self-contained breathing apparatus; required components. (a) Each self-contained breathing apparatus described in § 84.70 shall, where its design requires, contain the following...

  7. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS... 46 Shipping 3 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78...

  8. Technologies for Clinical Diagnosis Using Expired Human Breath Analysis

    PubMed Central

    Mathew, Thalakkotur Lazar; Pownraj, Prabhahari; Abdulla, Sukhananazerin; Pullithadathil, Biji

    2015-01-01

    This review elucidates the technologies in the field of exhaled breath analysis. Exhaled breath gas analysis offers an inexpensive, noninvasive and rapid method for detecting a large number of compounds under various conditions for health and disease states. There are various techniques to analyze some exhaled breath gases, including spectrometry, gas chromatography and spectroscopy. This review places emphasis on some of the critical biomarkers present in exhaled human breath, and its related effects. Additionally, various medical monitoring techniques used for breath analysis have been discussed. It also includes the current scenario of breath analysis with nanotechnology-oriented techniques. PMID:26854142

  9. Quantitative Analysis of Periodic Breathing and Very Long Apnea in Preterm Infants

    NASA Astrophysics Data System (ADS)

    Mohr, Mary A.

    Electronic signals from bedside monitors in University of Virginia's Neonatal Intensive Care Unit (NICU) are routinely collected and stored. The overall goal of our research is predictive monitoring: we seek patterns in signals that give early warning of impending pathology. This work focuses on apnea (pauses in regular respiration), and on periodic breathing (regular cycles of breathing and apnea). Our examination of apnea events revealed a disturbing number of cases in which the cessation of breathing lasted at least 60 seconds. These observations were validated, clinical correlations of these events were identified, and a theory was developed that partially explains how they occur. Periodic breathing in neonates is a normal developmental phenomenon. It arises when there is instability in the respiratory control system. A mathematical model of periodic breathing was developed to analyze the stability of the control system in infants. Periodic breathing has long been thought to be benign, however, exaggerated durations of periodic breathing may be an indicator of pathology. Characterization of periodic breathing has previously been limited to short monitoring times in small numbers of infants. An automated system for measurement and characterization of periodic breathing was developed and applied to 5 years of data from the NICU. The amount of periodic breathing that infants had was found to increase with gestational age (up to 32 weeks). Also, times of excessive periodic breathing were recorded and clinical correlations were sought. A significant increase in periodic breathing in the 24 hours before diagnosis of necrotizing enterocolitis was found.

  10. Physiological response of rats to delivery of helium and xenon: implications for hyperpolarized noble gas imaging

    NASA Technical Reports Server (NTRS)

    Ramirez, M. P.; Sigaloff, K. C.; Kubatina, L. V.; Donahue, M. A.; Venkatesh, A. K.; Albert, M. S.; ALbert, M. S. (Principal Investigator)

    2000-01-01

    The physiological effects of various hyperpolarized helium and xenon MRI-compatible breathing protocols were investigated in 17 Sprague-Dawley rats, by continuous monitoring of blood oxygen saturation, heart rate, EKG, temperature and endotracheal pressure. The protocols included alternating breaths of pure noble gas and oxygen, continuous breaths of pure noble gas, breath-holds of pure noble gas for varying durations, and helium breath-holds preceded by two helium rinses. Alternate-breath protocols up to 128 breaths caused a decrease in oxygen saturation level of less than 5% for either helium or xenon, whereas 16 continuous-breaths caused a 31.5% +/- 2.3% decrease in oxygen saturation for helium and a 30.7% +/- 1. 3% decrease for xenon. Breath-hold protocols up to 25 s did not cause the oxygen saturation to fall below 90% for either of the noble gases. Oxygen saturation values below 90% are considered pathological. At 30 s of breath-hold, the blood oxygen saturation dropped precipitously to 82% +/- 0.6% for helium, and to 76.5% +/- 7. 4% for xenon. Breath-holds longer than 10 s preceded by pre-rinses caused oxygen saturation to drop below 90%. These findings demonstrate the need for standardized noble gas inhalation procedures that have been carefully tested, and for continuous physiological monitoring to ensure the safety of the subject. We find short breath-hold and alternate-breath protocols to be safe procedures for use in hyperpolarized noble gas MRI experiments. Copyright 2000 John Wiley & Sons, Ltd.

  11. Relationship between dysfunctional breathing patterns and ability to achieve target heart rate variability with features of "coherence" during biofeedback.

    PubMed

    Courtney, Rosalba; Cohen, Marc; van Dixhoorn, Jan

    2011-01-01

    Heart rate variability (HRV) biofeedback is a self-regulation strategy used to improve conditions including asthma, stress, hypertension, and chronic obstructive pulmonary disease. Respiratory muscle function affects hemodynamic influences on respiratory sinus arrhythmia (RSA), and HRV and HRV-biofeedback protocols often include slow abdominal breathing to achieve physiologically optimal patterns of HRV with power spectral distribution concentrated around the 0.1-Hz frequency and large amplitude. It is likely that optimal balanced breathing patterns and ability to entrain heart rhythms to breathing reflect physiological efficiency and resilience and that individuals with dysfunctional breathing patterns may have difficulty voluntarily modulating HRV and RSA. The relationship between breathing movement patterns and HRV, however, has not been investigated. This study examines how individuals' habitual breathing patterns correspond with their ability to optimize HRV and RSA. Breathing pattern was assessed using the Manual Assessment of Respiratory Motion (MARM) and the Hi Lo manual palpation techniques in 83 people with possible dysfunctional breathing before they attempted HRV biofeedback. Mean respiratory rate was also assessed. Subsequently, participants applied a brief 5-minute biofeedback protocol, involving breathing and positive emotional focus, to achieve HRV patterns proposed to reflect physiological "coherence" and entrainment of heart rhythm oscillations to other oscillating body systems. Thoracic-dominant breathing was associated with decreased coherence of HRV (r = -.463, P = .0001). Individuals with paradoxical breathing had the lowest HRV coherence (t(8) = 10.7, P = .001), and the negative relationship between coherence of HRV and extent of thoracic breathing was strongest in this group (r = -.768, P = .03). Dysfunctional breathing patterns are associated with decreased ability to achieve HRV patterns that reflect cardiorespiratory efficiency and autonomic nervous system balance. This suggests that dysfunctional breathing patterns are not only biomechanically inefficient but also reflect decreased physiological resilience. Breathing assessment using simple manual techniques such as the MARM and Hi Lo may be useful in HRV biofeedback to identify if poor responders require more emphasis on correction of dysfunctional breathing.

  12. Changes in respiratory activity induced by mastication during oral breathing in humans.

    PubMed

    Daimon, Shigeru; Yamaguchi, Kazunori

    2014-06-01

    We examined the effect of oral breathing on respiratory movements, including the number of respirations and the movement of the thoracic wall at rest and while chewing gum. Forty normal nose breathers were selected by detecting expiratory airflow from the mouth using a CO2 sensor. Chest measurements were recorded using a Piezo respiratory belt transducer, and electromyographic (EMG) activity of the masseter and trapezius muscles were recorded at rest and while chewing gum during nasal or oral breathing. Oral breathing was introduced by completely occluding the nostrils with a nose clip. During oral breathing, the respiration rate was significantly lower while chewing gum than while at rest (P < 0.05). While chewing gum, the respiration rate was significantly lower during oral breathing than during nasal breathing (P < 0.05). During oral breathing, thoracic movement was significantly higher while chewing gum than while at rest (P < 0.05). Thoracic movement was significantly greater during oral breathing than during nasal breathing (P < 0.05). The trapezius muscle exhibited significant EMG activity when chewing gum during oral breathing. The activity of the trapezius muscle coincided with increased movement of the thoracic wall. Chewing food while breathing through the mouth interferes with and decreases the respiratory cycle and promotes unusual respiratory movement of the thoracic wall, which is directed by the activity of accessory muscles of respiration. Copyright © 2014 the American Physiological Society.

  13. Retropharyngeal abscess

    MedlinePlus

    ... between the ribs pull in when breathing ( intercostal retractions ) Severe throat pain Difficulty turning the head ... have: Breathing trouble High-pitched breathing sounds (stridor) Retraction of the muscles between the ribs when breathing ...

  14. Syllable-Related Breathing in Infants in the Second Year of Life

    ERIC Educational Resources Information Center

    Parham, Douglas F.; Buder, Eugene H.; Oller, D. Kimbrough; Boliek, Carol A.

    2011-01-01

    Purpose: This study explored whether breathing behaviors of infants within the 2nd year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Method: Vocalizations and breathing kinematics of 9 infants between 53 and 90 weeks of age were recorded. A strict selection…

  15. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  16. 21 CFR 862.3050 - Breath-alcohol test system.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breath-alcohol test system. 862.3050 Section 862....3050 Breath-alcohol test system. (a) Identification. A breath-alcohol test system is a device intened to measure alcohol in the human breath. Measurements obtained by this device are used in the...

  17. Optimal technique for deep breathing exercises after cardiac surgery.

    PubMed

    Westerdahl, E

    2015-06-01

    Cardiac surgery patients often develop a restrictive pulmonary impairment and gas exchange abnormalities in the early postoperative period. Chest physiotherapy is routinely prescribed in order to reduce or prevent these complications. Besides early mobilization, positioning and shoulder girdle exercises, various breathing exercises have been implemented as a major component of postoperative care. A variety of deep breathing maneuvres are recommended to the spontaneously breathing patient to reduce atelectasis and to improve lung function in the early postoperative period. Different breathing exercises are recommended in different parts of the world, and there is no consensus about the most effective breathing technique after cardiac surgery. Arbitrary instructions are given, and recommendations on performance and duration vary between hospitals. Deep breathing exercises are a major part of this therapy, but scientific evidence for the efficacy has been lacking until recently, and there is a lack of trials describing how postoperative breathing exercises actually should be performed. The purpose of this review is to provide a brief overview of postoperative breathing exercises for patients undergoing cardiac surgery via sternotomy, and to discuss and suggest an optimal technique for the performance of deep breathing exercises.

  18. Toward Anatomical Simulation for Breath Training in Mind/Body Medicine

    NASA Astrophysics Data System (ADS)

    Sanders, Benjamin; Dilorenzo, Paul; Zordan, Victor; Bakal, Donald

    The use of breath in healing is poorly understood by patients and professionals alike. Dysfunctional breathing is a characteristic of many unexplained symptoms and mind/body medical professionals seek methods for breath training to alleviate such problems. Our approach is to re-purpose and evolve a recently developed anatomically inspired respiration simulation which was created for synthesizing motion in entertainment for the use of visualization in breath training. In mind/body medicine, problems are often created from patients being advised to breathe according to some standard based on pace or volume. However, a breathing pattern that is comfortable and effortless for one person may not have the same benefits for the next person. The breathing rhythm which is most effortless for each person needs to be dynamically identified. To this end, in this chapter, we employ optimization to modify a generic model of respiration to fit the breath patterns of specific individuals. In practice, the corresponding visualization which is specific to individual patients could be used to train proper breath behavior, both by showing specific (abnormal) practice and recommended modification(s).

  19. Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements.

    PubMed

    Wang, Zhennan; Wang, Chuji

    2013-09-01

    Since the ancient discovery of the 'sweet odor' in human breath gas, pursuits of the breath analysis-based disease diagnostics have never stopped. Actually, the 'smell' of the breath, as one of three key disease diagnostic techniques, has been used in Eastern-Medicine for more than three thousand years. With advancement of measuring technologies in sensitivity and selectivity, more specific breath gas species have been identified and established as a biomarker of a particular disease. Acetone is one of the breath gases and its concentration in exhaled breath can now be determined with high accuracy using various techniques and methods. With the worldwide prevalence of diabetes that is typically diagnosed through blood testing, human desire to achieve non-blood based diabetic diagnostics and monitoring has never been quenched. Questions, such as is breath acetone a biomarker of diabetes and how is the breath acetone related to the blood glucose (BG) level (the golden criterion currently used in clinic for diabetes diagnostic, monitoring, and management), remain to be answered. A majority of current research efforts in breath acetone measurements and its technology developments focus on addressing the first question. The effort to tackle the second question has begun recently. The earliest breath acetone measurement in clearly defined diabetic patients was reported more than 60 years ago. For more than a half-century, as reviewed in this paper, there have been more than 41 independent studies of breath acetone using various techniques and methods, and more than 3211 human subjects, including 1581 healthy people, 242 Type 1 diabetic patients, 384 Type 2 diabetic patients, 174 unspecified diabetic patients, and 830 non-diabetic patients or healthy subjects who are under various physiological conditions, have been used in the studies. The results of the breath acetone measurements collected in this review support that many conditions might cause changes to breath acetone concentrations; however, the results from the six independent studies using clearly-defined Type 1 and Type 2 diabetic patients unanimously support that an elevated mean breath acetone concentration exists in Type 1 diabetes. Note that there is some overlap between the ranges of breath acetone concentration in individual T1D patients and healthy subjects; this reminds one to be careful when using an acetone breath test on T1D diagnostics. Comparatively, it is too early to draw a general conclusion on the relationship between a breath acetone level and a BG level from the very limited data in the literature.

  20. Effects of slow breathing rate on heart rate variability and arterial baroreflex sensitivity in essential hypertension.

    PubMed

    Li, Changjun; Chang, Qinghua; Zhang, Jia; Chai, Wenshu

    2018-05-01

    This study is to investigate the effects of slow breathing on heart rate variability (HRV) and arterial baroreflex sensitivity in essential hypertension.We studied 60 patients with essential hypertension and 60 healthy controls. All subjects underwent controlled breathing at 8 and 16 breaths per minute. Electrocardiogram, respiratory, and blood pressure signals were recorded simultaneously. We studied effects of slow breathing on heart rate, blood pressure and respiratory peak, high-frequency (HF) power, low-frequency (LF) power, and LF/HF ratio of HRV with traditional and corrected spectral analysis. Besides, we tested whether slow breathing was capable of modifying baroreflex sensitivity in hypertensive subjects.Slow breathing, compared with 16 breaths per minute, decreased the heart rate and blood pressure (all P < .05), and shifted respiratory peak toward left (P < .05). Compared to 16 breaths/minute, traditional spectral analysis showed increased LF power and LF/HF ratio, decreased HF power of HRV at 8 breaths per minute (P < .05). As breathing rate decreased, corrected spectral analysis showed increased HF power, decreased LF power, LF/HF ratio of HRV (P < .05). Compared to controls, resting baroreflex sensitivity decreased in hypertensive subjects. Slow breathing increased baroreflex sensitivity in hypertensive subjects (from 59.48 ± 6.39 to 78.93 ± 5.04 ms/mm Hg, P < .05) and controls (from 88.49 ± 6.01 to 112.91 ± 7.29 ms/mm Hg, P < .05).Slow breathing can increase HF power and decrease LF power and LF/HF ratio in essential hypertension. Besides, slow breathing increased baroreflex sensitivity in hypertensive subjects. These demonstrate slow breathing is indeed capable of shifting sympatho-vagal balance toward vagal activities and increasing baroreflex sensitivity, suggesting a safe, therapeutic approach for essential hypertension.

  1. Simultaneous Measurement of Breathing and Heartbeat using Airborne Ultrasound in a Standing Position

    NASA Astrophysics Data System (ADS)

    Hoshiba, Kotaro; Hirata, Shinnosuke; Hachiya, Hiroyuki

    We have been studied about non-contact measurement of respiration and heart rates. In previous papers, the measurement system of small velocity using the M-sequence-modulated signal and phase difference of reflected signals from the target has been proposed. In this paper, we describe measurement of breathing and heartbeat in a standing position using the proposed method. Body-surface velocities by breathing and heartbeat could be observed respectively when the volunteer was breathing and holding the breath. In addition, measured velocity of breathing volunteer includes the component by heartbeat. It is considered that it has possibility to measure breathing and heartbeat concurrently.

  2. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 1 2010-10-01 2010-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  3. 49 CFR 40.277 - Are alcohol tests other than saliva or breath permitted under these regulations?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 1 2011-10-01 2011-10-01 false Are alcohol tests other than saliva or breath... Testing § 40.277 Are alcohol tests other than saliva or breath permitted under these regulations? No.... Only saliva or breath for screening tests and breath for confirmation tests using approved devices are...

  4. Deep breathing after surgery

    MedlinePlus

    ... and taking big breaths can be uncomfortable. A device called an incentive spirometer can help you take deep breaths correctly. If you do not have this device, you can still practice deep breathing on your ...

  5. Breathing simulator of workers for respirator performance test.

    PubMed

    Yuasa, Hisashi; Kumita, Mikio; Honda, Takeshi; Kimura, Kazushi; Nozaki, Kosuke; Emi, Hitoshi; Otani, Yoshio

    2015-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker's respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns.

  6. Whole-heart magnetic resonance coronary angiography with multiple breath-holds and automatic breathing-level tracking

    NASA Astrophysics Data System (ADS)

    Kuhara, Shigehide; Ninomiya, Ayako; Okada, Tomohisa; Kanao, Shotaro; Kamae, Toshikazu; Togashi, Kaori

    2010-05-01

    Whole-heart (WH) magnetic resonance coronary angiography (MRCA) studies are usually performed during free breathing while monitoring the position of the diaphragm with real-time motion correction. However, this results in a long scan time and the patient's breathing pattern may change, causing the study to be aborted. Alternatively, WH MRCA can be performed with multiple breath-holds (mBH). However, one problem in the mBH method is that patients cannot hold their breath at the same position every time, leading to image degradation. We have developed a new WH MRCA imaging method that employs both the mBH method and automatic breathing-level tracking to permit automatic tracking of the changes in breathing or breath-hold levels. Evaluation of its effects on WH MRCA image quality showed that this method can provide high-quality images within a shorter scan time. This proposed method is expected to be very useful in clinical WH MRCA studies.

  7. Effect of upper costal and costo-diaphragmatic breathing types on electromyographic activity of respiratory muscles.

    PubMed

    Celhay, Isabel; Cordova, Rosa; Miralles, Rodolfo; Meza, Francisco; Erices, Pia; Barrientos, Camilo; Valenzuela, Saúl

    2015-04-01

    To compare electromyographic (EMG) activity in young-adult subjects with different breathing types. This study included 50 healthy male subjects with complete natural dentition, and no history of orofacial pain or craniomandibular-cervical-spinal disorders. Subjects were classified into two groups: upper costal breathing type, and costo-diaphragmatic breathing. Bipolar surface electrodes were located on sternocleidomastoid, diaphragm, external intercostal, and latissimus dorsi muscles. Electromyographic activity was recorded during the following tasks: (1) normal quiet breathing; (2) speaking the word 'Mississippi'; (3) swallowing saliva; and (4) forced deep breathing. Sternocleidomastoid and latissimus dorsi EMG activity was not significantly different between breathing types, whereas diaphragm and external intercostal EMG activity was significantly higher in the upper costal than costo-diaphragmatic breathing type in all tasks (P<0·05; Wilcoxon signed rank-sum test). Diaphragm and external intercostal EMG activity suggests that there could be differences in motor unit recruitment strategies depending on the breathing type.

  8. Increased oxygen load in the prefrontal cortex from mouth breathing: a vector-based near-infrared spectroscopy study.

    PubMed

    Sano, Masahiro; Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori

    2013-12-04

    Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (P<0.05), indicating an increased oxygen load. Mouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient's habitual breathing route than a patient interview.

  9. Increased oxygen load in the prefrontal cortex from mouth breathing: a vector-based near-infrared spectroscopy study

    PubMed Central

    Sano, Sayaka; Oka, Noriyuki; Yoshino, Kayoko; Kato, Toshinori

    2013-01-01

    Individuals who habitually breathe through the mouth are more likely than nasal breathers to have sleep disorders and attention deficit hyperactive disorder. We hypothesized that brain hemodynamic responses in the prefrontal cortex might be different for mouth and nasal breathing. To test this hypothesis, we measured changes in oxyhemoglobin and deoxyhemoglobin in the prefrontal cortex during mouth breathing and nasal breathing in healthy adults (n=9) using vector-based near-infrared spectroscopy. The angle k, calculated from changes in oxyhemoglobin and deoxyhemoglobin and indicating the degree of oxygen exchange, was significantly higher during mouth breathing (P<0.05), indicating an increased oxygen load. Mouth breathing also caused a significant increase in deoxyhemoglobin, but oxyhemoglobin did not increase. This difference in oxygen load in the brain arising from different breathing routes can be evaluated quantitatively using vector-based near-infrared spectroscopy. Phase responses could help to provide an earlier and more reliable diagnosis of a patient’s habitual breathing route than a patient interview. PMID:24169579

  10. Override of spontaneous respiratory pattern generator reduces cardiovascular parasympathetic influence

    NASA Technical Reports Server (NTRS)

    Patwardhan, A. R.; Vallurupalli, S.; Evans, J. M.; Bruce, E. N.; Knapp, C. F.

    1995-01-01

    We investigated the effects of voluntary control of breathing on autonomic function in cardiovascular regulation. Variability in heart rate was compared between 5 min of spontaneous and controlled breathing. During controlled breathing, for 5 min, subjects voluntarily reproduced their own spontaneous breathing pattern (both rate and volume on a breath-by-breath basis). With the use of this experimental design, we could unmask the effects of voluntary override of the spontaneous respiratory pattern generator on autonomic function in cardiovascular regulation without the confounding effects of altered respiratory pattern. Results from 10 subjects showed that during voluntary control of breathing, mean values of heart rate and blood pressure increased, whereas fractal and spectral powers in heart rate in the respiratory frequency region decreased. End-tidal PCO2 was similar during spontaneous and controlled breathing. These results indicate that the act of voluntary control of breathing decreases the influence of the vagal component, which is the principal parasympathetic influence in cardiovascular regulation.

  11. Hydrogen breath test in schoolchildren.

    PubMed Central

    Douwes, A C; Schaap, C; van der Klei-van Moorsel, J M

    1985-01-01

    The frequency of negative hydrogen breath tests due to colonic bacterial flora which are unable to produce hydrogen was determined after oral lactulose challenge in 98 healthy Dutch schoolchildren. There was a negative result in 9.2%. The probability of a false normal lactose breath test (1:77) was calculated from these results together with those from a separate group of children with lactose malabsorption (also determined by hydrogen breath test). A study of siblings and mothers of subjects with a negative breath test did not show familial clustering of this condition. Faecal incubation tests with various sugars showed an increase in breath hydrogen greater than 100 parts per million in those with a positive breath test while subjects with a negative breath test also had a negative faecal incubation test. The frequency of a false negative hydrogen breath test was higher than previously reported, but this does not affect the superiority of this method of testing over the conventional blood glucose determination. PMID:4004310

  12. New breathing functions for the transverse breathing crack of the cracked rotor system: Approach for critical and subcritical harmonic analysis

    NASA Astrophysics Data System (ADS)

    Al-Shudeifat, Mohammad A.; Butcher, Eric A.

    2011-01-01

    The actual breathing mechanism of the transverse breathing crack in the cracked rotor system that appears due to the shaft weight is addressed here. As a result, the correct time-varying area moments of inertia for the cracked element cross-section during shaft rotation are also determined. Hence, two new breathing functions are identified to represent the actual breathing effect on the cracked element stiffness matrix. The new breathing functions are used in formulating the time-varying finite element stiffness matrix of the cracked element. The finite element equations of motion are then formulated for the cracked rotor system and solved via harmonic balance method for response, whirl orbits and the shift in the critical and subcritical speeds. The analytical results of this approach are compared with some previously published results obtained using approximate formulas for the breathing mechanism. The comparison shows that the previously used breathing function is a weak model for the breathing mechanism in the cracked rotor even for small crack depths. The new breathing functions give more accurate results for the dynamic behavior of the cracked rotor system for a wide range of the crack depths. The current approach is found to be efficient for crack detection since the critical and subcritical shaft speeds, the unique vibration signature in the neighborhood of the subcritical speeds and the sensitivity to the unbalance force direction all together can be utilized to detect the breathing crack before further damage occurs.

  13. Patients' experiences of breathing retraining for asthma: a qualitative process analysis of participants in the intervention arms of the BREATHE trial.

    PubMed

    Arden-Close, Emily; Yardley, Lucy; Kirby, Sarah; Thomas, Mike; Bruton, Anne

    2017-10-05

    Poor symptom control and impaired quality of life are common in adults with asthma, and breathing retraining exercises may be an effective method of self-management. This study aimed to explore the experiences of participants in the intervention arms of the BREATHE trial, which investigated the effectiveness of breathing retraining as a mode of asthma management. Sixteen people with asthma (11 women, 8 per group) who had taken part in the intervention arms of the BREATHE trial (breathing retraining delivered by digital versatile disc (DVD) or face-to-face sessions with a respiratory physiotherapist) took part in semi-structured telephone interviews about their experiences. Interviews were analysed using thematic analysis. Breathing retraining was perceived positively as a method of asthma management. Motivations for taking part included being asked, to enhance progress in research, to feel better/reduce symptoms, and to reduce medication. Participants were positive about the physiotherapist, liked having the materials tailored, found meetings motivational, and liked the DVD and booklet. The impact of breathing retraining following regular practice included increased awareness of breathing and development of new habits. Benefits of breathing retraining included increased control over breathing, reduced need for medication, feeling more relaxed, and improved health and quality of life. Problems included finding time to practice the exercises, and difficulty mastering techniques. Breathing retraining was acceptable and valued by almost all participants, and many reported improved wellbeing. Face to face physiotherapy was well received. However, some participants in the DVD group mentioned being unable to master techniques. PATIENTS RECEPTIVE TO BREATHING RETRAINING: Patients with asthma taught how to change their unconscious breathing patterns generally like non-pharmacological interventions. Researchers in the UK, led by Mike Thomas from the University of Southampton, interviewed 16 people about their experiences in a trial that tested breathing retraining exercises delivered by DVD or face-to-face sessions with a respiratory physiotherapist. Overwhelmingly, trial participants reported that breathing retraining sessions gave them greater control over their symptoms, helped them relax, improved their quality of life and reduced the need for medications. Some participants who received DVD instruction said they had trouble mastering the techniques, and many in both groups found it hard to find time to practice the exercises. Overall, however, patients were positive about the experience. The authors conclude that breathing exercises are likely to be a well-received method of asthma management.

  14. Ammonia and ethylene biomarkers in the respiration of the people with schizophrenia using photoacoustic spectroscopy

    NASA Astrophysics Data System (ADS)

    Popa, Cristina; Petrus, Mioara; Bratu, Ana Maria

    2015-05-01

    Oxidative stress has become an exciting area of schizophrenia (SCZ) research, and provides ample opportunities and hope for a better understanding of its pathophysiology, which may lead to new treatment strategies. The first objective of the present study was to analyze the oxidative stress markers in breath samples of patients with SCZ before and after the treatment with Levomepromazine. The second objective was to analyze the deficiency of amino acids marker in breath samples of patients with SCZ before and after the treatment. Exhaled breath was collected from 15 SCZ patients and 19 healthy controls; subsequently, CO2 laser photoacoustic spectroscopy was used to assess the exhaled breath compounds of the study subjects. One of the main breath biomarkers of the oxidative stress is ethylene, while one of the main breath biomarkers of the amino acids deficiency is ammonia. The breath biomarkers in the exhalation of SCZ patients exhibited significant differences from the breath biomarkers in the exhalation of healthy controls. Analysis of breath ethylene and breath ammonia provides a related model of SCZ exhalation that could represent an effective and convenient screening method for this intellectual disability.

  15. Sports-related lung injury during breath-hold diving.

    PubMed

    Mijacika, Tanja; Dujic, Zeljko

    2016-12-01

    The number of people practising recreational breath-hold diving is constantly growing, thereby increasing the need for knowledge of the acute and chronic effects such a sport could have on the health of participants. Breath-hold diving is potentially dangerous, mainly because of associated extreme environmental factors such as increased hydrostatic pressure, hypoxia, hypercapnia, hypothermia and strenuous exercise.In this article we focus on the effects of breath-hold diving on pulmonary function. Respiratory symptoms have been reported in almost 25% of breath-hold divers after repetitive diving sessions. Acutely, repetitive breath-hold diving may result in increased transpulmonary capillary pressure, leading to noncardiogenic oedema and/or alveolar haemorrhage. Furthermore, during a breath-hold dive, the chest and lungs are compressed by the increasing pressure of water. Rapid changes in lung air volume during descent or ascent can result in a lung injury known as pulmonary barotrauma. Factors that may influence individual susceptibility to breath-hold diving-induced lung injury range from underlying pulmonary or cardiac dysfunction to genetic predisposition.According to the available data, breath-holding does not result in chronic lung injury. However, studies of large populations of breath-hold divers are necessary to firmly exclude long-term lung damage. Copyright ©ERS 2016.

  16. Exhaled breath temperature in children: reproducibility and influencing factors.

    PubMed

    Vermeulen, S; Barreto, M; La Penna, F; Prete, A; Martella, S; Biagiarelli, F; Villa, M P

    2014-09-01

    This study will investigate the reproducibility and influencing factors of exhaled breath temperature measured with the tidal breathing technique in asthmatic patients and healthy children. Exhaled breath temperature, fractional exhaled nitric oxide, and spirometry were assessed in 124 children (63 healthy and 61 asthmatic), aged 11.2 ± 2.5 year, M/F 73/51. A modified version of the American Thoracic Society questionnaire on the child's present and past respiratory history was obtained from parents. Parents were also asked to provide detailed information on their child's medication use during the previous 4 weeks. Ear temperature, ambient temperature, and relative-ambient humidity were also recorded. Exhaled breath temperature measurements were highly reproducible; the second measurement was higher than the first measurement, consistent with a test-retest situation. In 13 subjects, between-session within-day reproducibility of exhaled breath temperature was still high. Exhaled breath temperature increased with age and relative-ambient humidity. Exhaled breath temperature was comparable in healthy and asthmatic children; when adjusted for potential confounders (i.e. ambient conditions and subject characteristics), thermal values of asthmatic patients exceeded those of the healthy children by 1.1 °C. Normalized exhaled breath temperature, by subtracting ambient temperature, was lower in asthmatic patients treated with inhaled corticosteroids than in those who were corticosteroid-naive. Measurements of exhaled breath temperature are highly reproducible, yet influenced by several factors. Corrected values, i.e. normalized exhaled breath temperature, could help us to assess the effect of therapy with inhaled corticosteroids. More studies are needed to improve the usefulness of the exhaled breath temperature measured with the tidal breathing technique in children.

  17. Comparison of spontaneous vs. metronome-guided breathing on assessment of vagal modulation using RR variability.

    PubMed

    Bloomfield, D M; Magnano, A; Bigger, J T; Rivadeneira, H; Parides, M; Steinman, R C

    2001-03-01

    R-R interval variability (RR variability) is increasingly being used as an index of autonomic activity. High-frequency (HF) power reflects vagal modulation of the sinus node. Since vagal modulation occurs at the respiratory frequency, some investigators have suggested that HF power cannot be interpreted unless the breathing rate is controlled. We hypothesized that HF power during spontaneous breathing would not differ significantly from HF power during metronome-guided breathing. We measured HF power during spontaneous breathing in 20 healthy subjects and 19 patients with heart disease. Each subject's spontaneous breathing rate was determined, and the calculation of HF power was repeated with a metronome set to his or her average spontaneous breathing rate. There was no significant difference between the logarithm of HF power measured during spontaneous and metronome-guided breathing [4.88 +/- 0.29 vs. 5.29 +/- 0.30 ln(ms(2)), P = 0.32] in the group as a whole and when patients and healthy subjects were examined separately. We did observe a small (9.9%) decrease in HF power with increasing metronome-guided breathing rates (from 9 to 20 breaths/min). These data indicate that HF power during spontaneous and metronome-guided breathing differs at most by very small amounts. This variability is several logarithmic units less than the wide discrepancies observed between healthy subjects and cardiac patients with a heterogeneous group of cardiovascular disorders. In addition, HF power is relatively constant across the range of typical breathing rates. These data indicate that there is no need to control breathing rate to interpret HF power when RR variability (and specifically HF power) is used to identify high-risk cardiac patients.

  18. Guiding curve based on the normal breathing as monitored by thermocouple for regular breathing.

    PubMed

    Lim, Sangwook; Park, Sung Ho; Ahn, Seung Do; Suh, Yelin; Shin, Seong Soo; Lee, Sang-wook; Kim, Jong Hoon; Choi, Eun Kyoung; Yi, Byong Yong; Kwon, Soo Il; Kim, Sookil; Jeung, Tae Sig

    2007-11-01

    Adapting radiation fields to a moving target requires information continuously on the location of internal target by detecting it directly or indirectly. The aim of this study is to make the breathing regular effectively with minimizing stress to the patient. A system for regulating patient's breath consists of a respiratory monitoring mask (ReMM), a thermocouple module, a screen, inner earphones, and a personal computer. A ReMM with thermocouple was developed previously to measure the patient's respiration. A software was written in LabView 7.0 (National Instruments, TX), which acquires respiration signal and displays its pattern. Two curves are displayed on the screen: One is a curve indicating the patient's current breathing pattern; the other is a guiding curve, which is iterated with one period of the patient's normal breathing curve. The guiding curves were acquired for each volunteer before they breathed with guidance. Ten volunteers participated in this study to evaluate this system. A cycle of the representative guiding curve was acquired by monitoring each volunteer's free breathing with ReMM and was then generated iteratively. The regularity was compared between a free breath curve and a guided breath curve by measuring standard deviations of amplitudes and periods of two groups of breathing. When the breathing was guided, the standard deviation of amplitudes and periods on average were reduced from 0.0029 to 0.00139 (arbitrary units) and from 0.359 s to 0.202 s, respectively. And the correlation coefficients between breathing curves and guiding curves were greater than 0.99 for all volunteers. The regularity was improved statistically when the guiding curve was used.

  19. Transcriptomic Analysis of Compromise Between Air-Breathing and Nutrient Uptake of Posterior Intestine in Loach (Misgurnus anguillicaudatus), an Air-Breathing Fish.

    PubMed

    Huang, Songqian; Cao, Xiaojuan; Tian, Xianchang

    2016-08-01

    Dojo loach (Misgurnus anguillicaudatus) is an air-breathing fish species by using its posterior intestine to breathe on water surface. So far, the molecular mechanism about accessory air-breathing in fish is seldom addressed. Five cDNA libraries were constructed here for loach posterior intestines form T01 (the initial stage group), T02 (mid-stage of normal group), T03 (end stage of normal group), T04 (mid-stage of air-breathing inhibited group), and T05 (the end stage of air-breathing inhibited group) and subjected to perform RNA-seq to compare their transcriptomic profilings. A total of 92,962 unigenes were assembled, while 37,905 (40.77 %) unigenes were successfully annotated. 2298, 1091, and 3275 differentially expressed genes (fn1, ACE, EGFR, Pxdn, SDF, HIF, VEGF, SLC2A1, SLC5A8 etc.) were observed in T04/T02, T05/T03, and T05/T04, respectively. Expression levels of many genes associated with air-breathing and nutrient uptake varied significantly between normal and intestinal air-breathing inhibited group. Intraepithelial capillaries in posterior intestines of loaches from T05 were broken, while red blood cells were enriched at the surface of intestinal epithelial lining with 241 ± 39 cells per millimeter. There were periodic acid-schiff (PAS)-positive epithelial mucous cells in posterior intestines from both normal and air-breathing inhibited groups. Results obtained here suggested an overlap of air-breathing and nutrient uptake function of posterior intestine in loach. Intestinal air-breathing inhibition in loach would influence the posterior intestine's nutrient uptake ability and endothelial capillary structure stability. This study will contribute to our understanding on the molecular regulatory mechanisms of intestinal air-breathing in loach.

  20. An Acute Bout of a Controlled Breathing Frequency Lowers Sympathetic Neural Outflow but not Blood Pressure in Healthy Normotensive Subjects

    PubMed Central

    MCCLAIN, SHANNON L.; BROOKS, ALEXA M.; JARVIS, SARA S.

    2017-01-01

    Controlled or paced breathing is often used as a stress reduction technique but the impact on blood pressure (BP) and sympathetic outflow have not been consistently reported. The purpose of this study was to determine whether a controlled breathing (12 breaths/min, CB) rate would be similar to an individual’s spontaneous breathing (SB) rate. Secondly, would a CB rate of 12 breaths/min alter heart rate (HR), BP, and indices of muscle sympathetic nerve activity (MSNA). Twenty-one subjects (10 women, 11 men) performed two trials: SB, where the subject chose a comfortable breathing rate; and CB, where the subject breathed at a pace of 12 breaths/min. Each trial was 6 min during which respiratory waveforms, HR, BP (systolic, SBP; diastolic, DBP), and MSNA were recorded. During CB, the 6 min average breathing frequency (14±4 vs 12±1 breaths/min, P<0.05 for SB and CB, respectively), MSNA burst frequency (18±12 vs 14±10 bursts/min, P<0.01) and MSNA burst incidence (28±19 vs 21± 6 bursts/100 heart beats, P<0.01) were significantly lower than during SB. HR (66±9 vs 67±9 beats/min, P<0.05) was higher during CB. SBP (120±13 vs 121±15 mmHg, P=0.741), DBP (56±8 vs 57±9 mmHg, P=0.768), and MSNA total activity (166±94 vs 145±102 a.u./min, P=0.145) were not different between the breathing conditions. In conclusion, an acute reduction in breathing frequency such as that observed during CB elicited a decrease in indices of MSNA (burst frequency and incidence) with no change in BP. PMID:28344733

  1. Changes in cardiac output during swimming and aquatic hypoxia in the air-breathing Pacific tarpon.

    PubMed

    Clark, T D; Seymour, R S; Christian, K; Wells, R M G; Baldwin, J; Farrell, A P

    2007-11-01

    Pacific tarpon (Megalops cyprinoides) use a modified gas bladder as an air-breathing organ (ABO). We examined changes in cardiac output (V(b)) associated with increases in air-breathing that accompany exercise and aquatic hypoxia. Juvenile (0.49 kg) and adult (1.21 kg) tarpon were allowed to recover in a swim flume at 27 degrees C after being instrumented with a Doppler flow probe around the ventral aorta to monitor V(b) and with a fibre-optic oxygen sensor in the ABO to monitor air-breathing frequency. Under normoxic conditions and in both juveniles and adults, routine air-breathing frequency was 0.03 breaths min(-1) and V(b) was about 15 mL min(-1) kg(-1). Normoxic exercise (swimming at about 1.1 body lengths s(-1)) increased air-breathing frequency by 8-fold in both groups (reaching 0.23 breaths min(-1)) and increased V(b) by 3-fold for juveniles and 2-fold for adults. Hypoxic exposure (2 kPa O2) at rest increased air-breathing frequency 19-fold (to around 0.53 breaths min(-1)) in both groups, and while V(b) again increased 3-fold in resting juvenile fish, V(b) was unchanged in resting adult fish. Exercise in hypoxia increased air-breathing frequency 35-fold (to 0.95 breaths min(-1)) in comparison with resting normoxic fish. While juvenile fish increased V(b) nearly 2-fold with exercise in hypoxia, adult fish maintained the same V(b) irrespective of exercise state and became agitated in comparison. These results imply that air-breathing during exercise and hypoxia can benefit oxygen delivery, but to differing degrees in juvenile and adult tarpon. We discuss this difference in the context of myocardial oxygen supply.

  2. Role of the superior pharyngeal constrictor muscle in forced breathing in dogs.

    PubMed

    Yaman, Z; Kogo, M; Senoo, H; Iida, S; Ishii, S; Matsuya, T

    2000-03-01

    Respiratory-related electromyographic (EMG) activity of the superior pharyngeal constrictor (SPC) muscle was analyzed during the early stage of forced breathing. Four adult dogs anesthetized with sodium pentobarbital were used. In the first part of the study, oral and nasal breathing tubes were placed into the respective cavities, and a tracheotomy tube was placed in the second part of the study. Two conditions, the presence (oral-nasal tube breathing) and absence (tracheotomy breathing) of airflow in the upper airway, were achieved in each dog. Following quiet breathing, animals were connected to a closed breathing system, first by an oral-nasal tube and then by a tracheotomy tube. We proposed to induce a forced breathing condition mechanically by using this system for 1 minute. We increased resistance to airflow during forced breathing by means of connecting tubes and a bag. Our aim was not to produce chemical drive but to produce a forced respiration by increasing the resistance to airflow. Tidal volume, breathing frequency, minute volume, chest wall movement, and EMG activity of the SPC muscle were measured and analyzed. During quiet breathing through an oral-nasal or tracheotomy tube, low-amplitude EMG activity of the SPC muscle corresponding to the expiratory cycle of the respiration was observed. In both study conditions, phasic expiratory EMG activity increased immediately after the advent of the breathing from the closed system. Tidal volumes and frequencies also increased rapidly during forced breathing. An increase in the resistance to airflow increased the activity of the SPC muscle. This augmented respiratory activity probably assists the patency of the upper airway. The augmented respiratory activity was independent of the local reflex pathways. Respiratory-related activity of the SPC muscle may help dilate and stiffen the pharyngeal airway, promoting airway patency.

  3. An Acute Bout of a Controlled Breathing Frequency Lowers Sympathetic Neural Outflow but not Blood Pressure in Healthy Normotensive Subjects.

    PubMed

    McClain, Shannon L; Brooks, Alexa M; Jarvis, Sara S

    2017-01-01

    Controlled or paced breathing is often used as a stress reduction technique but the impact on blood pressure (BP) and sympathetic outflow have not been consistently reported. The purpose of this study was to determine whether a controlled breathing (12 breaths/min, CB) rate would be similar to an individual's spontaneous breathing (SB) rate. Secondly, would a CB rate of 12 breaths/min alter heart rate (HR), BP, and indices of muscle sympathetic nerve activity (MSNA). Twenty-one subjects (10 women, 11 men) performed two trials: SB, where the subject chose a comfortable breathing rate; and CB, where the subject breathed at a pace of 12 breaths/min. Each trial was 6 min during which respiratory waveforms, HR, BP (systolic, SBP; diastolic, DBP), and MSNA were recorded. During CB, the 6 min average breathing frequency (14±4 vs 12±1 breaths/min, P <0.05 for SB and CB, respectively), MSNA burst frequency (18±12 vs 14±10 bursts/min, P <0.01) and MSNA burst incidence (28±19 vs 21± 6 bursts/100 heart beats, P <0.01) were significantly lower than during SB. HR (66±9 vs 67±9 beats/min, P <0.05) was higher during CB. SBP (120±13 vs 121±15 mmHg, P =0.741), DBP (56±8 vs 57±9 mmHg, P =0.768), and MSNA total activity (166±94 vs 145±102 a.u./min, P =0.145) were not different between the breathing conditions. In conclusion, an acute reduction in breathing frequency such as that observed during CB elicited a decrease in indices of MSNA (burst frequency and incidence) with no change in BP.

  4. A probability-based multi-cycle sorting method for 4D-MRI: A simulation study.

    PubMed

    Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing

    2016-12-01

    To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients' breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors' preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management.

  5. Work of Breathing into Snow in the Presence versus Absence of an Artificial Air Pocket Affects Hypoxia and Hypercapnia of a Victim Covered with Avalanche Snow: A Randomized Double Blind Crossover Study.

    PubMed

    Roubík, Karel; Sieger, Ladislav; Sykora, Karel

    2015-01-01

    Presence of an air pocket and its size play an important role in survival of victims buried in the avalanche snow. Even small air pockets facilitate breathing. We hypothesize that the size of the air pocket significantly affects the airflow resistance and work of breathing. The aims of the study are (1) to investigate the effect of the presence of an air pocket on gas exchange and work of breathing in subjects breathing into the simulated avalanche snow and (2) to test whether it is possible to breathe with no air pocket. The prospective interventional double-blinded study involved 12 male volunteers, from which 10 completed the whole protocol. Each volunteer underwent two phases of the experiment in a random order: phase "AP"--breathing into the snow with a one-liter air pocket, and phase "NP"--breathing into the snow with no air pocket. Physiological parameters, fractions of oxygen and carbon dioxide in the airways and work of breathing expressed as pressure-time product were recorded continuously. The main finding of the study is that it is possible to breath in the avalanche snow even with no air pocket (0 L volume), but breathing under this condition is associated with significantly increased work of breathing. The significant differences were initially observed for end-tidal values of the respiratory gases (EtO2 and EtCO2) and peripheral oxygen saturation (SpO2) between AP and NP phases, whereas significant differences in inspiratory fractions occurred much later (for FIO2) or never (for FICO2). The limiting factor in no air pocket conditions is excessive increase in work of breathing that induces increase in metabolism accompanied by higher oxygen consumption and carbon dioxide production. The presence of even a small air pocket reduces significantly the work of breathing.

  6. Ventilation is unstable during drowsiness before sleep onset.

    PubMed

    Thomson, Stuart; Morrell, Mary J; Cordingley, Jeremy J; Semple, Stephen J

    2005-11-01

    Ventilation is unstable during drowsiness before sleep onset. We have studied the effects of transitory changes in cerebral state during drowsiness on breath duration and lung volume in eight healthy subjects in the absence of changes in airway resistance and fluctuations of ventilation and CO2 tension, characteristic of the onset of non-rapid eye movement sleep. A volume-cycled ventilator in the assist control mode was used to maintain CO2 tension close to that when awake. Changes in cerebral state were determined by the EEG on a breath-by-breath basis and classified as alpha or theta breaths. Breath duration and the pause in gas flow between the end of expiratory airflow and the next breath were computed for two alpha breaths which preceded a theta breath and for the theta breath itself. The group mean (SD) results for this alpha-to-theta transition was associated with a prolongation in breath duration from 5.2 (SD 1.3) to 13.0 s (SD 2.1) and expiratory pause from 0.7 (SD 0.4) to 7.5 s (SD 2.2). Because the changes in arterial CO2 tension (PaCO2) are unknown during the theta breaths, we made in two subjects a continuous record of PaCO2 in the radial artery. PaCO2 remained constant from the alpha breaths through to the expiratory period of the theta breath by which time the duration of breath was already prolonged, representing an immediate and altered ventilatory response to the prevailing PaCO2. In the eight subjects, the CO2 tension awake was 39.6 Torr (SD 2.3) and on assisted ventilation 38.0 Torr (1.4). We conclude that the ventilatory instability recorded in the present experiments is due to the apneic threshold for CO2 being at or just below that when awake.

  7. SU-E-J-178: A Normalization Method Can Remove Discrepancy in Ventilation Function Due to Different Breathing Patterns

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Qu, H; Yu, N; Stephans, K

    2014-06-01

    Purpose: To develop a normalization method to remove discrepancy in ventilation function due to different breathing patterns. Methods: Twenty five early stage non-small cell lung cancer patients were included in this study. For each patient, a ten phase 4D-CT and the voluntarily maximum inhale and exhale CTs were acquired clinically and retrospectively used for this study. For each patient, two ventilation maps were calculated from voxel-to-voxel CT density variations from two phases of the quiet breathing and two phases of the extreme breathing. For the quiet breathing, 0% (inhale) and 50% (exhale) phases from 4D-CT were used. An in-house toolmore » was developed to calculate and display the ventilation maps. To enable normalization, the whole lung of each patient was evenly divided into three parts in the longitude direction at a coronal image with a maximum lung cross section. The ratio of cumulated ventilation from the top one-third region to the middle one-third region of the lung was calculated for each breathing pattern. Pearson's correlation coefficient was calculated on the ratios of the two breathing patterns for the group. Results: For each patient, the ventilation map from the quiet breathing was different from that of the extreme breathing. When the cumulative ventilation was normalized to the middle one-third of the lung region for each patient, the normalized ventilation functions from the two breathing patterns were consistent. For this group of patients, the correlation coefficient of the normalized ventilations for the two breathing patterns was 0.76 (p < 0.01), indicating a strong correlation in the ventilation function measured from the two breathing patterns. Conclusion: For each patient, the ventilation map is dependent of the breathing pattern. Using a regional normalization method, the discrepancy in ventilation function induced by the different breathing patterns thus different tidal volumes can be removed.« less

  8. MO-FG-BRA-02: A Feasibility Study of Integrating Breathing Audio Signal with Surface Surrogates for Respiratory Motion Management

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lei, Y; Zhu, X; Zheng, D

    Purpose: Tracking the surrogate placed on patient skin surface sometimes leads to problematic signals for certain patients, such as shallow breathers. This in turn impairs the 4D CT image quality and dosimetric accuracy. In this pilot study, we explored the feasibility of monitoring human breathing motion by integrating breathing sound signal with surface surrogates. Methods: The breathing sound signals were acquired though a microphone attached adjacently to volunteer’s nostrils, and breathing curve were analyzed using a low pass filter. Simultaneously, the Real-time Position Management™ (RPM) system from Varian were employed on a volunteer to monitor respiratory motion including both shallowmore » and deep breath modes. The similar experiment was performed by using Calypso system, and three beacons taped on volunteer abdominal region to capture breath motion. The period of each breathing curves were calculated with autocorrelation functions. The coherence and consistency between breathing signals using different acquisition methods were examined. Results: Clear breathing patterns were revealed by the sound signal which was coherent with the signal obtained from both the RPM system and Calypso system. For shallow breathing, the periods of breathing cycle were 3.00±0.19 sec (sound) and 3.00±0.21 sec (RPM); For deep breathing, the periods were 3.49± 0.11 sec (sound) and 3.49±0.12 sec (RPM). Compared with 4.54±0.66 sec period recorded by the calypso system, the sound measured 4.64±0.54 sec. The additional signal from sound could be supplement to the surface monitoring, and provide new parameters to model the hysteresis lung motion. Conclusion: Our preliminary study shows that the breathing sound signal can provide a comparable way as the RPM system to evaluate the respiratory motion. It’s instantaneous and robust characteristics facilitate it possibly to be a either independently or as auxiliary methods to manage respiratory motion in radiotherapy.« less

  9. Oxygen and carbon dioxide sensitivity of ventilation in amphibious crabs, Cardisoma guanhumi, breathing air and water.

    PubMed

    Gannon, Andrew T; Henry, Raymond P

    2004-05-01

    Amphibious crabs, Cardisoma guanhumi, were acclimated to breathing either air or water and exposed to altered levels of oxygen and/or carbon dioxide in the medium. Hypercapnia (22, 36 and 73 torr CO(2)) stimulated a significant hypercapnic ventilatory response (HCVR) in both groups of crabs, with a much greater effect on scaphognathite frequency (Deltaf(SC)=+700%) in air-breathing crabs than water-breathing crabs (Deltaf(SC)=+100%). In contrast, hyperoxia induced significant hypoventilation in both sets of crabs. However, simultaneous hyperoxia and hypercapnia triggered a greater than 10-fold increase in f(SC) in air-breathing crabs but no change in water-breathing crabs. For water-breathing crabs hypoxia simultaneous with hypercapnia triggered the same response as hypoxia alone-bradycardia (-50%), and a significant increase in f(SC) at moderate exposures but not at the more extreme levels. The response of air-breathing crabs to hypoxia concurrent with hypercapnia was proportionally closer to the response to hypercapnia alone than to hypoxia. Thus, C. guanhumi were more sensitive to ambient CO(2) than O(2) when breathing air, characteristic of fully terrestrial species, and more sensitive to ambient O(2) when breathing water, characteristic of fully aquatic species. C. guanhumi possesses both an O(2)- and a CO(2)-based ventilatory drive whether breathing air or water, but the relative importance switches when the respiratory medium is altered.

  10. Improved oxygenation during standing performance of deep breathing exercises with positive expiratory pressure after cardiac surgery: A randomized controlled trial.

    PubMed

    Pettersson, Henrik; Faager, Gun; Westerdahl, Elisabeth

    2015-09-01

    Breathing exercises after cardiac surgery are often performed in a sitting position. It is unknown whether oxygenation would be better in the standing position. The aim of this study was to evaluate oxygenation and subjective breathing ability during sitting vs standing performance of deep breathing exercises on the second day after cardiac surgery. Patients undergoing coronary artery bypass grafting (n = 189) were randomized to sitting (controls) or standing. Both groups performed 3 × 10 deep breaths with a positive expiratory pressure device. Peripheral oxygen saturation was measured before, directly after, and 15 min after the intervention. Subjective breathing ability, blood pressure, heart rate, and pain were assessed. Oxygenation improved significantly in the standing group compared with controls directly after the breathing exercises (p < 0.001) and after 15 min rest (p = 0.027). The standing group reported better deep breathing ability compared with controls (p = 0.004). A slightly increased heart rate was found in the standing group (p = 0.047). After cardiac surgery, breathing exercises with positive expiratory pressure, performed in a standing position, significantly improved oxygenation and subjective breathing ability compared with sitting performance. Performance of breathing exercises in the standing position is feasible and could be a valuable treatment for patients with postoperative hypoxaemia.

  11. Dental arch dimensional changes after adenotonsillectomy in prepubertal children.

    PubMed

    Petraccone Caixeta, Anna Cristina; Andrade, Ildeu; Bahia Junqueira Pereira, Tatiana; Franco, Letícia Paiva; Becker, Helena Maria Gonçalves; Souki, Bernardo Quiroga

    2014-04-01

    The purposes of this study were to investigate the dental arch changes after adenotonsillectomies in prepubertal children and to compare the dental arch dimensions of mouth-breathing and nasal-breathing children. The sample included 49 prepubertal severely obstructed mouth-breathing children and 46 prepubertal nasal-breathing children. Twenty-four of the 49 mouth-breathing children had an adenotonsillectomy and composed the adenotonsillectomy subgroup. The 25 children in whom the mouth-breathing pattern was unchanged during the 1-year study period composed the control subgroup. The mouth-breathing children showed a deeper palatal vault, a larger mandibular width, and a larger mandibular arch length in comparison with the nasal-breathing children. After airway clearance, the adenotonsillectomy group showed a significant maxillary transverse width gain compared with the control subgroup. The control subgroup showed a significant deepening of the palatal height when compared with the adenotonsillectomy subgroup after 1 year. The adenotonsillectomy subgroup had a significantly different pattern of arch development compared with the untreated controls. After adenotonsillectomy, the mouth-breathing children showed greater maxillary transverse development than did the controls. The palatal vault deepened in the untreated children. The mouth-breathing children showed a deeper palatal vault, a larger mandibular width, and a larger mandibular arch length in comparison with the nasal-breathing children. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  12. Analysis of Exhaled Breath for Disease Detection

    NASA Astrophysics Data System (ADS)

    Amann, Anton; Miekisch, Wolfram; Schubert, Jochen; Buszewski, Bogusław; Ligor, Tomasz; Jezierski, Tadeusz; Pleil, Joachim; Risby, Terence

    2014-06-01

    Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography-mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.

  13. Effects of breathing frequency and flow rate on the total inward leakage of an elastomeric half-mask donned on an advanced manikin headform.

    PubMed

    He, Xinjian; Grinshpun, Sergey A; Reponen, Tiina; McKay, Roy; Bergman, Michael S; Zhuang, Ziqing

    2014-03-01

    The objective of this study was to investigate the effects of breathing frequency and flow rate on the total inward leakage (TIL) of an elastomeric half-mask donned on an advanced manikin headform and challenged with combustion aerosols. An elastomeric half-mask respirator equipped with P100 filters was donned on an advanced manikin headform covered with life-like soft skin and challenged with aerosols originated by burning three materials: wood, paper, and plastic (polyethylene). TIL was determined as the ratio of aerosol concentrations inside (C in) and outside (C out) of the respirator (C in/C out) measured with a nanoparticle spectrometer operating in the particle size range of 20-200nm. The testing was performed under three cyclic breathing flows [mean inspiratory flow (MIF) of 30, 55, and 85 l/min] and five breathing frequencies (10, 15, 20, 25, and 30 breaths/min). A completely randomized factorial study design was chosen with four replicates for each combination of breathing flow rate and frequency. Particle size, MIF, and combustion material had significant (P < 0.001) effects on TIL regardless of breathing frequency. Increasing breathing flow decreased TIL. Testing with plastic aerosol produced higher mean TIL values than wood and paper aerosols. The effect of the breathing frequency was complex. When analyzed using all combustion aerosols and MIFs (pooled data), breathing frequency did not significantly (P = 0.08) affect TIL. However, once the data were stratified according to combustion aerosol and MIF, the effect of breathing frequency became significant (P < 0.05) for all MIFs challenged with wood and paper combustion aerosols, and for MIF = 30 l/min only when challenged with plastic combustion aerosol. The effect of breathing frequency on TIL is less significant than the effects of combustion aerosol and breathing flow rate for the tested elastomeric half-mask respirator. The greatest TIL occurred when challenged with plastic aerosol at 30 l/min and at a breathing frequency of 30 breaths/min.

  14. A fully integrated standalone portable cavity ringdown breath acetone analyzer.

    PubMed

    Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji

    2015-09-01

    Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.

  15. A fully integrated standalone portable cavity ringdown breath acetone analyzer

    NASA Astrophysics Data System (ADS)

    Sun, Meixiu; Jiang, Chenyu; Gong, Zhiyong; Zhao, Xiaomeng; Chen, Zhuying; Wang, Zhennan; Kang, Meiling; Li, Yingxin; Wang, Chuji

    2015-09-01

    Breath analysis is a promising new technique for nonintrusive disease diagnosis and metabolic status monitoring. One challenging issue in using a breath biomarker for potential particular disease screening is to find a quantitative relationship between the concentration of the breath biomarker and clinical diagnostic parameters of the specific disease. In order to address this issue, we need a new instrument that is capable of conducting real-time, online breath analysis with high data throughput, so that a large scale of clinical test (more subjects) can be achieved in a short period of time. In this work, we report a fully integrated, standalone, portable analyzer based on the cavity ringdown spectroscopy technique for near-real time, online breath acetone measurements. The performance of the portable analyzer in measurements of breath acetone was interrogated and validated by using the certificated gas chromatography-mass spectrometry. The results show that this new analyzer is useful for reliable online (online introduction of a breath sample without pre-treatment) breath acetone analysis with high sensitivity (57 ppb) and high data throughput (one data per second). Subsequently, the validated breath analyzer was employed for acetone measurements in 119 human subjects under various situations. The instrument design, packaging, specifications, and future improvements were also described. From an optical ringdown cavity operated by the lab-set electronics reported previously to this fully integrated standalone new instrument, we have enabled a new scientific tool suited for large scales of breath acetone analysis and created an instrument platform that can even be adopted for study of other breath biomarkers by using different lasers and ringdown mirrors covering corresponding spectral fingerprints.

  16. Human breath metabolomics using an optimized noninvasive exhaled breath condensate sampler

    PubMed Central

    Zamuruyev, Konstantin O.; Aksenov, Alexander A.; Pasamontes, Alberto; Brown, Joshua F.; Pettit, Dayna R.; Foutouhi, Soraya; Weimer, Bart C.; Schivo, Michael; Kenyon, Nicholas J.; Delplanque, Jean-Pierre; Davis, Cristina E.

    2017-01-01

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017). PMID:28004639

  17. Comparative transcriptome analysis between aquatic and aerial breathing organs of Channa argus to reveal the genetic basis underlying bimodal respiration.

    PubMed

    Jiang, Yanliang; Feng, Shuaisheng; Xu, Jian; Zhang, Songhao; Li, Shangqi; Sun, Xiaoqing; Xu, Peng

    2016-10-01

    Aerial breathing in fish was an important adaption for successful survival in hypoxic water. All aerial breathing fish are bimodal breathers. It is intriguing that they can obtain oxygen from both air and water. However, the genetic basis underlying bimodal breathing has not been extensively studied. In this study, we performed next-generation sequencing on a bimodal breathing fish, the Northern snakehead, Channa argus, and generated a transcriptome profiling of C. argus. A total of 53,591 microsatellites and 26,378 SNPs were identified and classified. A Ka/Ks analysis of the unigenes indicated that 63 genes were under strong positive selection. Furthermore, the transcriptomes from the aquatic breathing organ (gill) and the aerial breathing organ (suprabranchial chamber) were sequenced and compared, and the results showed 1,966 genes up-regulated in the gill and 2,727 genes up-regulated in the suprabranchial chamber. A gene pathway analysis concluded that four functional categories were significant, of which angiogenesis and elastic fibre formation were up-regulated in the suprabranchial chamber, indicating that the aerial breathing organ may be more efficient for gas exchange due to its highly vascularized and elastic structure. In contrast, ion uptake and transport and acid-base balance were up-regulated in the gill, indicating that the aquatic breathing organ functions in ion homeostasis and acid-base balance, in addition to breathing. Understanding the genetic mechanism underlying bimodal breathing will shed light on the initiation and importance of aerial breathing in the evolution of vertebrates. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Human breath metabolomics using an optimized non-invasive exhaled breath condensate sampler.

    PubMed

    Zamuruyev, Konstantin O; Aksenov, Alexander A; Pasamontes, Alberto; Brown, Joshua F; Pettit, Dayna R; Foutouhi, Soraya; Weimer, Bart C; Schivo, Michael; Kenyon, Nicholas J; Delplanque, Jean-Pierre; Davis, Cristina E

    2016-12-22

    Exhaled breath condensate (EBC) analysis is a developing field with tremendous promise to advance personalized, non-invasive health diagnostics as new analytical instrumentation platforms and detection methods are developed. Multiple commercially-available and researcher-built experimental samplers are reported in the literature. However, there is very limited information available to determine an effective breath sampling approach, especially regarding the dependence of breath sample metabolomic content on the collection device design and sampling methodology. This lack of an optimal standard procedure results in a range of reported results that are sometimes contradictory. Here, we present a design of a portable human EBC sampler optimized for collection and preservation of the rich metabolomic content of breath. The performance of the engineered device is compared to two commercially available breath collection devices: the RTube ™ and TurboDECCS. A number of design and performance parameters are considered, including: condenser temperature stability during sampling, collection efficiency, condenser material choice, and saliva contamination in the collected breath samples. The significance of the biological content of breath samples, collected with each device, is evaluated with a set of mass spectrometry methods and was the primary factor for evaluating device performance. The design includes an adjustable mass-size threshold for aerodynamic filtering of saliva droplets from the breath flow. Engineering an inexpensive device that allows efficient collection of metalomic-rich breath samples is intended to aid further advancement in the field of breath analysis for non-invasive health diagnostic. EBC sampling from human volunteers was performed under UC Davis IRB protocol 63701-3 (09/30/2014-07/07/2017).

  19. Benzene levels in ambient air and breath of smokers and nonsmokers in urban and pristine environments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wester, R.C.; Maibach, H.I.; Gruenke, L.D.

    Benzene levels in human breath and in ambient air were compared in the urban area of San Francisco (SF) and in a more remote coastal pristine setting of Stinson Beach, Calif. (SB). Benzene analysis was done by gas chromatography-mass spectroscopy (GC-MS). Ambient benzene levels were sevenfold higher in SF (2.6 +/- 1.3 ppb, n = 25) than SB (0.38 +/- 0.39 ppb, n = 21). In SF, benzene in smokers' breath (6.8 +/- 3.0 ppb) was greater than in nonsmokers' breath (2.5 +/- 0.8 ppb) and smokers' ambient air (3.3 +/- 0.8 ppb). In SB the same pattern was observed:more » benzene in smokers' breath was higher than in nonsmokers' breath and ambient air. Benzene in SF nonsmokers' breath was greater than in SB nonsmokers' breath. Marijuana-only smokers had benzene breath levels between those of smokers and nonsmokers. There was little correlation between benzene in breath and number of cigarettes smoked, or with other benzene exposures such as diet. Of special interest was the finding that benzene in breath of SF nonsmokers (2.5 +/- 0.8 ppb) was greater than that in nonsmokers ambient air (1.4 +/- 0.1 ppb). The same was true in SB, where benzene in nonsmokers breath was greater than ambient air (1.8 +/- 0.2 ppb versus 1.0 +/- 0.1 ppb on d 1 and 1.3 +/- 0.3 ppb versus 0.23 +/- 0.18 ppb on d 2). This suggests an additional source of benzene other than outdoor ambient air.« less

  20. Study of the detectability of controlled substances on breath

    DOT National Transportation Integrated Search

    1975-07-01

    The University of Missouri used high pressure liquid chromatography plus mass spectrometry for a quantitative analysis of marijuana metabolites in blood and breath. A breath collector was developed for road-side sampling of human breath and subsequen...

  1. [Reliability study on the infrared spectrometry for measuring the delta over baseline for breath 13C].

    PubMed

    Wang, Min; Wang, Zhiling; Gou, Lingyan; Zhang, Yuhui; Yang, Xiaoguang; Sha, Lei; Li, Min

    2013-03-01

    To assess the validity and reliability of the infrared spectrometry for measuring the delta over baseline for breath 13C. Twenty-four healthy adults were selected, including twelve males and twelve females. 13C-Leucine was used as tracer in stable isotope metabolic experiments. One baseline breath was collected before the tracer protocol began. Other breath samples were collected at 60, 120, 180, 195, 210, 225, 240, 255, 270 and 300 min post-tracer challenge. The delta over baseline for breath 13C was measured by the infrared spectrometry and Heliview 13C breath analyzer. No significant differences were found between the infrared spectrometry and Heliview 13C breath analyzer in measuring the delta over baseline for breath 13C. The F value and p value of two-way ANOVA were 0.29 and 0.5874 respectively. The t and p value of consistency test were 0.48 and 0.6346 respectively. The 13C infrared spectrometry can reliably measure the delta over baseline for breath 13C.

  2. Recent analytical approaches to detect exhaled breath ammonia with special reference to renal patients.

    PubMed

    Krishnan, Sanduru Thamarai; Devadhasan, Jasmine Pramila; Kim, Sanghyo

    2017-01-01

    The ammonia odor from the exhaled breath of renal patients is associated with high levels of blood urea nitrogen. Typically, in the liver, ammonia and ammonium ions are converted into urea through the urea cycle. In the case of renal dysfunction, urea is unable to be removed and that causes a buildup of excessive ammonia. As small molecules, ammonia and ammonium ions can be forced into the blood-lung barrier and occur in exhaled breath. Therefore, people with renal failure have an ammonia (fishy) odor in their exhaled breath. Thus, exhaled breath ammonia can be a potential biomarker for monitoring renal diseases during hemodialyis. In this review, we have summarized the source of ammonia in the breath of end-stage renal disease patient, cause of renal disorders, exhaled breath condensate, and breath sampling. Further, various biosensor approaches to detect exhaled ammonia from renal patients and other ammonia systems are also discussed. We conclude with future perspectives, namely colorimetric-based real-time breathing diagnosis of renal failure, which might be useful for prospective studies.

  3. Breathing simulator of workers for respirator performance test

    PubMed Central

    YUASA, Hisashi; KUMITA, Mikio; HONDA, Takeshi; KIMURA, Kazushi; NOZAKI, Kosuke; EMI, Hitoshi; OTANI, Yoshio

    2014-01-01

    Breathing machines are widely used to evaluate respirator performance but they are capable of generating only limited air flow patterns, such as, sine, triangular and square waves. In order to evaluate the respirator performance in practical use, it is desirable to test the respirator using the actual breathing patterns of wearers. However, it has been a difficult task for a breathing machine to generate such complicated flow patterns, since the human respiratory volume changes depending on the human activities and workload. In this study, we have developed an electromechanical breathing simulator and a respiration sampling device to record and reproduce worker’s respiration. It is capable of generating various flow patterns by inputting breathing pattern signals recorded by a computer, as well as the fixed air flow patterns. The device is equipped with a self-control program to compensate the difference in inhalation and exhalation volume and the measurement errors on the breathing flow rate. The system was successfully applied to record the breathing patterns of workers engaging in welding and reproduced the breathing patterns. PMID:25382381

  4. Breath in the technoscientific imaginary

    PubMed Central

    Rose, Arthur

    2016-01-01

    Breath has a realist function in most artistic media. It serves to remind the reader, the viewer or the spectator of the exigencies of the body. In science fiction (SF) literature and films, breath is often a plot device for human encounters with otherness, either with alien peoples, who may not breathe oxygen, or environments, where there may not be oxygen to breathe. But while there is a technoscientific quality to breath in SF, especially in its attention to physiological systems, concentrating on the technoscientific threatens to occlude other, more affective aspects raised by the literature. In order to supplement the tendency to read SF as a succession of technoscientific accounts of bodily experience, this paper recalls how SF texts draw attention to the affective, non-scientific qualities of breath, both as a metonym for life and as a metaphor for anticipation. Through an engagement with diverse examples from SF literature and films, this article considers the tension between technoscientific and affective responses to breath in order to demonstrate breath's co-determinacy in SF's blending of scientific and artistic discourses. PMID:27542677

  5. Breathing and sense of self: visuo-respiratory conflicts alter body self-consciousness.

    PubMed

    Adler, Dan; Herbelin, Bruno; Similowski, Thomas; Blanke, Olaf

    2014-11-01

    Bodily self-consciousness depends on the processing of interoceptive and exteroceptive signals. It can be disrupted by inducing signal conflicts. Breathing, at the crossroad between interoception and exteroception, should contribute to bodily self-consciousness. We induced visuo-respiratory conflicts in 17 subjects presented with a virtual body or a parallelepidedal object flashing synchronously or asynchronously with their breathing. A questionnaire detected illusory changes in bodily self-consciousness and breathing agency (the feeling of sensing one's breathing command). Changes in self-location were tested by measuring reaction time during mental ball drop (MBD). Synchronous illumination changed the perceived location of breathing (body: p=0.008 vs. asynchronous; object: p=0.013). It resulted in a significant change in breathing agency, but no changes in self-identification. This was corroborated by prolonged MBD reaction time (body: +0.045s, 95%CI [0.013; 0.08], p=0.007). We conclude that breathing modulates bodily self-consciousness. We also conclude that one can induce the irruption of unattended breathing into consciousness without modifying respiratory mechanics or gas exchange. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Control of Breathing During Mechanical Ventilation: Who Is the Boss?

    PubMed Central

    Williams, Kathleen; Hinojosa-Kurtzberg, Marina; Parthasarathy, Sairam

    2011-01-01

    Over the past decade, concepts of control of breathing have increasingly moved from being theoretical concepts to “real world” applied science. The purpose of this review is to examine the basics of control of breathing, discuss the bidirectional relationship between control of breathing and mechanical ventilation, and critically assess the application of this knowledge at the patient’s bedside. The principles of control of breathing remain under-represented in the training curriculum of respiratory therapists and pulmonologists, whereas the day-to-day bedside application of the principles of control of breathing continues to suffer from a lack of outcomes-based research in the intensive care unit. In contrast, the bedside application of the principles of control of breathing to ambulatory subjects with sleep-disordered breathing has out-stripped that in critically ill patients. The evolution of newer technologies, faster real-time computing abilities, and miniaturization of ventilator technology can bring the concepts of control of breathing to the bedside and benefit the critically ill patient. However, market forces, lack of scientific data, lack of research funding, and regulatory obstacles need to be surmounted. PMID:21333174

  7. Are questionnaires reliable in diagnosing sleep-disordered breathing in university students?

    PubMed

    Migacz, E; Wichniak, A; Kukwa, W

    2017-11-01

    This study aimed to screen young adults for sleep-disordered breathing, and compare those with high and low risk for sleep-disordered breathing. A survey based on the Berlin questionnaire was completed by 330 university students, and the results were used to divide them into sleep-disordered breathing positive and sleep-disordered breathing negative groups. A representative group was selected from each cohort (positive group, n = 16; negative group, n = 21), and assessed with sleep study, ENT examination, the Nose Obstruction Symptom Evaluation scale, and the Epworth Sleepiness Scale. Sleep-disordered breathing prevalence was 11.2 per cent in the questionnaire and 24 per cent according to the sleep study. The sleep-disordered breathing positive and negative groups significantly differed in terms of coexisting sleep-disordered breathing symptoms. There were no significant differences between the positive and negative groups with regard to sleep study parameters (apnoea/hypopnoea index, respiratory disturbance index, oxygen desaturation index, snoring intensity) and the Epworth Sleepiness Scale. Subjective and objective diagnostic tools revealed that sleep-disordered breathing is a common problem among young adults.

  8. A cross-sectional study of breath acetone based on diabetic metabolic disorders.

    PubMed

    Li, Wenwen; Liu, Yong; Lu, Xiaoyong; Huang, Yanping; Liu, Yu; Cheng, Shouquan; Duan, Yixiang

    2015-02-26

    Breath acetone is a known biomarker for diabetes mellitus in breath analysis. In this work, a cross-sectional study of breath acetone based on clinical metabolic disorders of type 2 diabetes mellitus (T2DM) was carried out. Breath acetone concentrations of 113 T2DM patients and 56 apparently healthy individuals were measured at a single time point. Concentrations varied from 0.22 to 9.41 ppmv (mean 1.75 ppmv) for T2DM, which were significantly higher than those for normal controls (ranged from 0.32 to 1.96 ppmv, mean 0.72 ppmv, p = 0.008). Observations in our work revealed that breath acetone concentrations elevated to different degrees, along with the abnormality of blood glucose, glycated hemoglobin (HbA1c), triglyceride and cholesterol. Breath acetone showed obviously positive correlations with blood ketone and urine ketone. Possible metabolic relations between breath acetone and diabetic disorders were also discussed. This work aimed at giving an overall assessment of breath acetone from the perspective of clinical parameters for type 2 diabetes.

  9. Detection of pulmonary metastases with pathological correlation: effect of breathing on the accuracy of spiral CT.

    PubMed

    Coakley, F V; Cohen, M D; Waters, D J; Davis, M M; Karmazyn, B; Gonin, R; Hanna, M P

    1997-07-01

    CT of the chest for suspected pulmonary metastases in adults is generally performed using a breath-hold technique. The results may not be applicable to young children in whom breath-holding may be impossible. Determine the effect of breathing on the accuracy of pulmonary metastasis detection by spiral CT (SCT). Prior to euthanasia four anesthetized dogs with metastatic osteosarcoma underwent SCT with a collimation of 5 mm and a pitch of 2, during both induced breath-hold and normal quiet breathing. Images were reconstructed as contiguous 5-mm slices. Macroscopically evident metastases were noted at postmortem. Hard-copy SCT images were reviewed by ten radiologists, each of whom circled all suspected metastases. SCT images were compared with postmortem results to determine true and false positives. The pathologist identified 132 macroscopically evident pulmonary metastases. For metastasis detection, there was no significant difference between breath-hold SCT and breathing SCT. In our animal model, SCT can be performed during normal resting breathing without significant loss of accuracy in the detection of pulmonary metastases.

  10. Emptying patterns of the lung studied by multiple-breath N2 washout

    NASA Technical Reports Server (NTRS)

    Lewis, S. M.

    1978-01-01

    Changes in the nitrogen concentration seen during the single-breath nitrogen washout reflect changes in relative flow (ventilation) from units with differing ventilation/volume ratios. The multiple-breath washout provides sufficient data on ventilation for units with varying ventilation/volume ratios to be plotted as a function of the volume expired. Flow from the dead space may also be determined. In young normals the emptying patterns are narrow and unimodal throughout the alveolar plateau with little or no flow from the dead space at the end of the breath. Older normals show more flow from the dead space, particularly toward the end of the breath, and some show a high ventilation/volume ratio mode early in the breath. Patients with obstructive lung disease have a high flow from the dead space which is present throughout the breath. A well ventilated mode at the end of the breath is seen in some obstructed subjects. Patients with cystic fibrosis showed a poorly ventilated mode appearing at the end of the breath as well as a very high dead space.

  11. The impact of breathing rate on the cardiac autonomic dynamics among children with cerebral palsy compared to typically developed controls.

    PubMed

    Amichai, Taly; Eylon, Sharon; Berger, Itai; Katz-Leurer, Michal

    2018-02-06

    To describe the immediate effect of breathing rate on heart rate (HR) and heart rate variability (HRV) in children with cerebral palsy (CP) and a control group of typically developed (TD) age and gender-matched children. Twenty children with CP at gross motor function classification system levels I-III and 20 TD children aged 6-11 participated in the study. HR was monitored at rest and during paced breathing with biofeedback. Respiratory measures were assessed by KoKo spirometry. Children with CP have lower spirometry and HRV values at rest compared to TD children. The mean reduction of breathing rate during paced breathing among children with CP was significantly smaller. Nonetheless, while practicing paced breathing, both groups reduced their breathing rate and increased their HRV. The results of the current work present the immediate effect of paced breathing on HRV parameters in CP and TD children. Further studies are needed to investigate the effect of long-term treatment focusing on paced breathing for children with CP.

  12. Determination of breath acetone in 149 type 2 diabetic patients using a ringdown breath-acetone analyzer.

    PubMed

    Sun, Meixiu; Chen, Zhuying; Gong, Zhiyong; Zhao, Xiaomeng; Jiang, Chenyu; Yuan, Yuan; Wang, Zhennang; Li, Yingxin; Wang, Chuji

    2015-02-01

    Over 90% of diabetic patients have Type 2 diabetes. Although an elevated mean breath acetone concentration has been found to exist in Type 1 diabetes (T1D), information on breath acetone in Type 2 diabetes (T2D) has yet to be obtained. In this study, we first used gas chromatography-mass spectrometry (GC-MS) to validate a ringdown breath-acetone analyzer based on the cavity-ringdown-spectroscopy technique, through comparing breath acetone concentrations in the range 0.5-2.5 ppm measured using both methods. The linear fitting of R = 0.99 suggests that the acetone concentrations obtained using both methods are consistent with a largest standard deviation of ±0.4 ppm in the lowest concentration of the range. Next, 620 breath samples from 149 T2D patients and 42 healthy subjects were collected and tested using the breath analyzer. Four breath samples were taken from each subject under each of four different conditions: fasting, 2 h post-breakfast, 2 h post-lunch, and 2 h post-dinner. Simultaneous blood glucose levels were also measured using a standard diabetic-management blood-glucose meter. For the 149 T2D subjects, their exhaled breath acetone concentrations ranged from 0.1 to 19.8 ppm; four different ranges of breath acetone concentration, 0.1-19.8, 0.1-7.1, 0.1-6.3, and 0.1-9.5 ppm, were obtained for the subjects under the four different conditions, respectively. For the 42 healthy subjects, their breath acetone concentration ranged from 0.1 to 2.6 ppm; four different ranges of breath acetone concentration, 0.3-2.6, 0.1-2.6, 0.1-1.7, and 0.3-1.6 ppm, were obtained for the four different conditions. The mean breath acetone concentration of the 149 T2D subjects was determined to be 1.5 ± 1.5 ppm, which was 1.5 times that of 1.0 ± 0.6 ppm for the 42 healthy subjects. No correlation was found between the breath acetone concentration and the blood glucose level of the T2D subjects and the healthy volunteers. This study using a relatively large number of subjects provides new data regarding breath acetone in diabetes (T1D and T2D) and suggests that an elevated mean breath acetone concentration also exists in T2D.

  13. A visual stethoscope to detect the position of the tracheal tube.

    PubMed

    Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito

    2009-12-01

    Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P < 0.01). When unilateral breath sounds were auscultated, the tube was located at 2.6 +/- 1.2 cm on the bronchial side of the carina. The tube was also located at 2.3 +/- 1.0 cm on the bronchial side of the carina when a unilateral shape of visualized breath sounds was obtained using the Visual Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the visualized breath sounds using the Visual Stethoscope appeared before the changes of the breath sounds were detected by auscultation. Bilateral breath sounds disappeared when the tip of the tracheal tube was advanced beyond the carina in both groups.

  14. A dual mode breath sampler for the collection of the end-tidal and dead space fractions.

    PubMed

    Salvo, P; Ferrari, C; Persia, R; Ghimenti, S; Lomonaco, T; Bellagambi, F; Di Francesco, F

    2015-06-01

    This work presents a breath sampler prototype automatically collecting end-tidal (single and multiple breaths) or dead space air fractions (multiple breaths). This result is achieved by real time measurements of the CO2 partial pressure and airflow during the expiratory and inspiratory phases. Suitable algorithms, used to control a solenoid valve, guarantee that a Nalophan(®) bag is filled with the selected breath fraction even if the subject under test hyperventilates. The breath sampler has low pressure drop (<0.5 kPa) and uses inert or disposable components to avoid bacteriological risk for the patients and contamination of the breath samples. A fully customisable software interface allows a real time control of the hardware and software status. The performances of the breath sampler were evaluated by comparing (a) the CO2 partial pressure calculated during the sampling with the CO2 pressure measured off-line within the Nalophan(®) bag; (b) the concentrations of four selected volatile organic compounds in dead space, end-tidal and mixed breath fractions. Results showed negligible deviations between calculated and off-line CO2 pressure values and the distributions of the selected compounds into dead space, end-tidal and mixed breath fractions were in agreement with their chemical-physical properties. Copyright © 2015. Published by Elsevier Ltd.

  15. The effect of mouth breathing on chewing efficiency.

    PubMed

    Nagaiwa, Miho; Gunjigake, Kaori; Yamaguchi, Kazunori

    2016-03-01

    To examine the effect of mouth breathing on chewing efficiency by evaluating masticatory variables. Ten adult nasal breathers with normal occlusion and no temporomandibular dysfunction were selected. Subjects were instructed to bite the chewing gum on the habitual side. While breathing through the mouth and nose, the glucide elution from the chewing gum, number of chewing strokes, duration of chewing, and electromyography (EMG) activity of the masseter muscle were evaluated as variables of masticatory efficiency. The durations required for the chewing of 30, 60, 90, 120, 180, and 250 strokes were significantly (P < .05) longer while breathing through the mouth. There was no significant difference in the glucide elution rate (%) for each chewing stroke between nose and mouth breathings. The glucide elution rates for 1- and 3-minute chewing were significantly (P < .05) lower while breathing through the mouth. However, there was no significant difference in the glucide elution rate for 5-minute chewing between nose and mouth breathings. While chewing for 1, 3, and 5 minutes, the chewing stroke and EMG activity of the masseter muscle were significantly (P < .05) lower during mouth breathing. It takes a longer amount of time to complete chewing to obtain higher masticatory efficiency when breathing through the mouth. Therefore, mouth breathing will decrease the masticatory efficiency if the duration of chewing is restricted in everyday life.

  16. Chemical sensors for breath gas analysis: the latest developments at the Breath Analysis Summit 2013.

    PubMed

    Tisch, Ulrike; Haick, Hossam

    2014-06-01

    Profiling the body chemistry by means of volatile organic compounds (VOCs) in the breath opens exciting new avenues in medical diagnostics. Gas sensors could provide ideal platforms for realizing portable, hand-held breath testing devices in the near future. This review summarizes the latest developments and applications in the field of chemical sensors for diagnostic breath testing that were presented at the Breath Analysis Summit 2013 in Wallerfangen, Germany. Considerable progress has been made towards clinically applicable breath testing devices, especially by utilizing chemo-sensitive nanomaterials. Examples of several specialized breath testing applications are presented that are either based on stand-alone nanomaterial-based sensors being highly sensitive and specific to individual breath compounds over others, or on combinations of several highly specific sensors, or on experimental nanomaterial-based sensors arrays. Other interesting approaches include the adaption of a commercially available MOx-based sensor array to indirect breath testing applications, using a sample pre-concentration method, and the development of compact integrated GC-sensor systems. The recent trend towards device integration has led to the development of fully integrated prototypes of point-of-care devices. We describe and compare the performance of several prototypes that are based on different sensing technologies and evaluate their potential as low-cost and readily available next-generation medical devices.

  17. Breath acidification in adolescent runners exposed to atmospheric pollution: A prospective, repeated measures observational study

    PubMed Central

    Ferdinands, Jill M; Crawford, Carol A Gotway; Greenwald, Roby; Van Sickle, David; Hunter, Eric; Teague, W Gerald

    2008-01-01

    Background Vigorous outdoors exercise during an episode of air pollution might cause airway inflammation. The purpose of this study was to examine the effects of vigorous outdoor exercise during peak smog season on breath pH, a biomarker of airway inflammation, in adolescent athletes. Methods We measured breath pH both pre- and post-exercise on ten days during peak smog season in 16 high school athletes engaged in daily long-distance running in a downwind suburb of Atlanta. The association of post-exercise breath pH with ambient ozone and particulate matter concentrations was tested with linear regression. Results We collected 144 pre-exercise and 146 post-exercise breath samples from 16 runners (mean age 14.9 years, 56% male). Median pre-exercise breath pH was 7.58 (interquartile range: 6.90 to 7.86) and did not change significantly after exercise. We observed no significant association between ambient ozone or particulate matter and post-exercise breath pH. However both pre- and post-exercise breath pH were strikingly low in these athletes when compared to a control sample of 14 relatively sedentary healthy adults and to published values of breath pH in healthy subjects. Conclusion Although we did not observe an acute effect of air pollution exposure during exercise on breath pH, breath pH was surprisingly low in this sample of otherwise healthy long-distance runners. We speculate that repetitive vigorous exercise may induce airway acidification. PMID:18328105

  18. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.

    PubMed

    Kimura, Tetsuro; Suzuki, Akira; Mimuro, Soichiro; Makino, Hiroshi; Sato, Shigehito

    2012-12-01

    We created a system that allows the visualization of breath sounds (visual stethoscope). We compared the visual stethoscope technique with auscultation for the detection of bronchial intubation in pediatric patients. In the auscultation group, an anesthesiologist advanced the tracheal tube, while another anesthesiologist auscultated bilateral breath sounds to detect the change and/or disappearance of unilateral breath sounds. In the visualization group, the stethoscope was used to detect changes in breath sounds and/or disappearance of unilateral breath sounds. The distance from the edge of the mouth to the carina was measured using a fiberoptic bronchoscope. Forty pediatric patients were enrolled in the study. At the point at which irregular breath sounds were auscultated, the tracheal tube was located at 0.5 ± 0.8 cm on the bronchial side from the carina. When a detectable change of shape of the visualized breath sound was observed, the tracheal tube was located 0.1 ± 1.2 cm on the bronchial side (not significant). At the point at which unilateral breath sounds were auscultated or a unilateral shape of the visualized breath sound was observed, the tracheal tube was 1.5 ± 0.8 or 1.2 ± 1.0 cm on the bronchial side, respectively (not significant). The visual stethoscope allowed to display the left and the right lung sound simultaneously and detected changes of breath sounds and unilateral breath sound as a tracheal tube was advanced. © 2012 Blackwell Publishing Ltd.

  19. 13C-methacetin and 13C-galactose breath tests can assess restricted liver function even in early stages of primary biliary cirrhosis.

    PubMed

    Holtmeier, Julia; Leuschner, Maria; Schneider, Arne; Leuschner, Ulrich; Caspary, Wolfgang F; Braden, Barbara

    2006-11-01

    The 13C-methacetin breath test quantitatively evaluates cytochrome P450-dependent liver function. The 13C-galactose breath test non-invasively measures the galactose oxidation capacity of the liver. The aim of this study was to find out whether these breath tests are sensitive parameters also in non-cirrhotic patients with primary biliary cirrhosis. Nineteen patients with early-stage primary biliary cirrhosis (no cirrhotic alterations in the liver biopsy, Ludwig stage I-III) and 20 healthy controls underwent the 13C-methacetin and 13C-galactose breath tests. Patients with primary biliary cirrhosis metabolized less 13C-methacetin than controls (cumulative recovery within 30 min 7.5+/-2.4% versus 14.0+/-2.6%; p < 0.001). When a cut-off > 9.8% was used for the cumulative recovery after 30 min, the methacetin breath test reached 84.2% sensitivity and 95.0 specificity. In the 13C-galactose breath test, the percentage recovery at 60 min in patients was 3.1+/-1.3%/h, and 6.3+/-1.1%/h in controls (p < 0.001). Using a cut-off > 4.7%/h, the galactose breath test reached 89.5% sensitivity and 95.0 specificity. In non-cirrhotic, early-stage, primary biliary cirrhosis the 13C-methacetin breath test and the 13C-galactose breath test reliably indicate decreased liver function. The 13C-galactose breath test can also predict the histological score.

  20. The importance of a normal breathing pattern for an effective abdominal-hollowing maneuver in healthy people: an experimental study.

    PubMed

    Ha, Sung-min; Kwon, Oh-yun; Kim, Su-jung; Choung, Sung-dae

    2014-02-01

    A normal breathing pattern while performing the abdominal-hollowing (AH) maneuver or spinal-stabilization exercise is essential for the success of rehabilitation programs and exercises. In previous studies, subjects were given standardized instructions to control the influence of respiration during the AH maneuver. However, the effect of breathing pattern on abdominal-muscle thickness during the AH maneuver has not been investigated. To compare abdominal-muscle thickness in subjects performing the AH maneuver under normal and abnormal breathing-pattern conditions and to investigate the effect of breathing pattern on the preferential contraction ratio (PCR) of the transverse abdominis. Comparative, repeated-measures experimental study. University research laboratory. 16 healthy subjects (8 male, 8 female) from a university population. A real-time ultrasound scanner was used to measure abdominal-muscle thickness during normal and abnormal breathing patterns. A paired t test was used to assess the effect of breathing pattern on abdominal-muscle thickness and PCR. Muscle thickness in the transverse abdominis and internal oblique muscles was significantly greater under the normal breathing pattern than under the abnormal pattern (P < .05). The PCR of the transverse abdominis was significantly higher under the normal breathing pattern compared with the abnormal pattern (P < .05). The results indicate that a normal breathing pattern is essential for performance of an effective AH maneuver. Thus, clinicians should ensure that patients adopt a normal breathing pattern before performing the AH maneuver and monitor transverse abdominis activation during the maneuver.

  1. Application of drug testing using exhaled breath for compliance monitoring of drug addicts in treatment.

    PubMed

    Carlsson, Sten; Olsson, Robert; Lindkvist, Irene; Beck, Olof

    2015-04-01

    Exhaled breath has recently been identified as a possible matrix for drug testing. This study explored the potential of this new method for compliance monitoring of patients being treated for dependence disorders. Outpatients in treatment programs were recruited for this study. Urine was collected as part of clinical routine and a breath sample was collected in parallel together with a questionnaire about their views of the testing procedure. Urine was analyzed for amphetamines, benzodiazepines, cannabis, cocaine, buprenorphine, methadone and opiates using CEDIA immunochemical screening and mass spectrometry confirmation. The exhaled breath was collected using the SensAbues device and analyzed by mass spectrometry for amphetamine, methamphetamine, diazepam, oxazepam, tetrahydrocannabinol, cocaine, benzoylecgonine, buprenorphine, methadone, morphine, codeine and 6-acetylmorphine. A total of 122 cases with parallel urine and breath samples were collected; 34 of these were negative both in urine and breath. Out of 88 cases with positive urine samples 51 (58%) were also positive in breath. Among the patients on methadone treatment, all were positive for methadone in urine and 83% were positive in breath. Among patients in treatment with buprenorphine, 92% were positive in urine and among those 80% were also positive in breath. The questionnaire response documented that in general, patients accepted drug testing well and that the breath sampling procedure was preferred. Compliance testing for the intake of prescribed and unprescribed drugs among patients in treatment for dependence disorders using the exhaled breath sampling technique is a viable method and deserves future attention.

  2. Effect of waveforms of inspired gas tension on the respiratory oscillations of carotid body discharge.

    PubMed

    Kumar, P; Nye, P C; Torrance, R W

    1991-07-01

    The responses of carotid body chemoreceptor discharge to repeated ramps (20- to 60-s forcing cycle durations) of inspired gas tensions were studied in spontaneously breathing and in artificially ventilated pentobarbitone-anesthetized cats. In all animals the mean intensity of chemoreceptor discharge followed the frequency of the forcing cycle, and superimposed on this were oscillations at the frequency of ventilation (breath-by-breath oscillations). The amplitude of the breath-by-breath oscillations in discharge was often large, and it waxed and waned with the forcing cycle. It was greatest when the mean level of discharge was falling and smallest near the peak of mean discharge. No qualitative differences were observed between PO2-alone forcing in constant normocapnia and PCO2-alone forcing in constant hypoxia. The variation in the amplitudes of breath-by-breath oscillations was shown to be due primarily to variations in the amplitudes of the downslope component of the discharge oscillation. Variations in the upslope component of individual oscillations were small. The factors responsible for the breath-by-breath oscillations are discussed, and it is concluded that the shape of the waveform of arterial gas tensions that stimulate the peripheral chemoreceptors departs markedly from that of a line joining end-tidal gas tensions. This causes breath-by-breath oscillations of discharge to be very large after an "off" stimulus. Reflex studies involving the forcing of respiratory gases should therefore include consideration of these effects.

  3. 3D Late Gadolinium Enhancement in a Single Prolonged Breath-hold using Supplemental Oxygenation and Hyperventilation

    PubMed Central

    Roujol, Sébastien; Basha, Tamer A.; Akçakaya, Mehmet; Foppa, Murilo; Chan, Raymond H.; Kissinger, Kraig V.; Goddu, Beth; Berg, Sophie; Manning, Warren J.; Nezafat, Reza

    2013-01-01

    Purpose: To evaluate the feasibility of 3D single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Methods: Breath-hold metrics (breath-hold duration, diaphragmatic/LV position drift, and maximum variation of RR interval) without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (FOV=320×320×100 mm3, resolution=1.6×1.6×5.0 mm3, acceleration rate of 4) and a free breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semi-quantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Results: Supplemental oxygenation and hyperventilation increased the breath-hold duration (35±11 s to 58±21 s, p<0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both p>0.01). LGE images were of similar quality when compared to free breathing acquisitions but with reduced total scan time (85±22 s to 35±6 s, p<0.001). Conclusions: Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. PMID:24186772

  4. BreathDx - molecular analysis of exhaled breath as a diagnostic test for ventilator-associated pneumonia: protocol for a European multicentre observational study.

    PubMed

    van Oort, Pouline M P; Nijsen, Tamara; Weda, Hans; Knobel, Hugo; Dark, Paul; Felton, Timothy; Rattray, Nicholas J W; Lawal, Oluwasola; Ahmed, Waqar; Portsmouth, Craig; Sterk, Peter J; Schultz, Marcus J; Zakharkina, Tetyana; Artigas, Antonio; Povoa, Pedro; Martin-Loeches, Ignacio; Fowler, Stephen J; Bos, Lieuwe D J

    2017-01-03

    The diagnosis of ventilator-associated pneumonia (VAP) remains time-consuming and costly, the clinical tools lack specificity and a bedside test to exclude infection in suspected patients is unavailable. Breath contains hundreds to thousands of volatile organic compounds (VOCs) that result from host and microbial metabolism as well as the environment. The present study aims to use breath VOC analysis to develop a model that can discriminate between patients who have positive cultures and who have negative cultures with a high sensitivity. The Molecular Analysis of Exhaled Breath as Diagnostic Test for Ventilator-Associated Pneumonia (BreathDx) study is a multicentre observational study. Breath and bronchial lavage samples will be collected from 100 and 53 intubated and ventilated patients suspected of VAP. Breath will be analysed using Thermal Desorption - Gas Chromatography - Mass Spectrometry (TD-GC-MS). The primary endpoint is the accuracy of cross-validated prediction for positive respiratory cultures in patients that are suspected of VAP, with a sensitivity of at least 99% (high negative predictive value). To our knowledge, BreathDx is the first study powered to investigate whether molecular analysis of breath can be used to classify suspected VAP patients with and without positive microbiological cultures with 99% sensitivity. UKCRN ID number 19086, registered May 2015; as well as registration at www.trialregister.nl under the acronym 'BreathDx' with trial ID number NTR 6114 (retrospectively registered on 28 October 2016).

  5. A probability-based multi-cycle sorting method for 4D-MRI: A simulation study

    PubMed Central

    Liang, Xiao; Yin, Fang-Fang; Liu, Yilin; Cai, Jing

    2016-01-01

    Purpose: To develop a novel probability-based sorting method capable of generating multiple breathing cycles of 4D-MRI images and to evaluate performance of this new method by comparing with conventional phase-based methods in terms of image quality and tumor motion measurement. Methods: Based on previous findings that breathing motion probability density function (PDF) of a single breathing cycle is dramatically different from true stabilized PDF that resulted from many breathing cycles, it is expected that a probability-based sorting method capable of generating multiple breathing cycles of 4D images may capture breathing variation information missing from conventional single-cycle sorting methods. The overall idea is to identify a few main breathing cycles (and their corresponding weightings) that can best represent the main breathing patterns of the patient and then reconstruct a set of 4D images for each of the identified main breathing cycles. This method is implemented in three steps: (1) The breathing signal is decomposed into individual breathing cycles, characterized by amplitude, and period; (2) individual breathing cycles are grouped based on amplitude and period to determine the main breathing cycles. If a group contains more than 10% of all breathing cycles in a breathing signal, it is determined as a main breathing pattern group and is represented by the average of individual breathing cycles in the group; (3) for each main breathing cycle, a set of 4D images is reconstructed using a result-driven sorting method adapted from our previous study. The probability-based sorting method was first tested on 26 patients’ breathing signals to evaluate its feasibility of improving target motion PDF. The new method was subsequently tested for a sequential image acquisition scheme on the 4D digital extended cardiac torso (XCAT) phantom. Performance of the probability-based and conventional sorting methods was evaluated in terms of target volume precision and accuracy as measured by the 4D images, and also the accuracy of average intensity projection (AIP) of 4D images. Results: Probability-based sorting showed improved similarity of breathing motion PDF from 4D images to reference PDF compared to single cycle sorting, indicated by the significant increase in Dice similarity coefficient (DSC) (probability-based sorting, DSC = 0.89 ± 0.03, and single cycle sorting, DSC = 0.83 ± 0.05, p-value <0.001). Based on the simulation study on XCAT, the probability-based method outperforms the conventional phase-based methods in qualitative evaluation on motion artifacts and quantitative evaluation on tumor volume precision and accuracy and accuracy of AIP of the 4D images. Conclusions: In this paper the authors demonstrated the feasibility of a novel probability-based multicycle 4D image sorting method. The authors’ preliminary results showed that the new method can improve the accuracy of tumor motion PDF and the AIP of 4D images, presenting potential advantages over the conventional phase-based sorting method for radiation therapy motion management. PMID:27908178

  6. Results of the first semi-annual qualification testing of devices to measure breath alcohol

    DOT National Transportation Integrated Search

    1975-01-01

    Eight evidential breath testers were performance tested according to the Standard for Devices to Measure Breath Alcohol Federal Register, Vol 38, No. 212, November 5, 1973. In addition, a prototype breath tester not commercially available was tested....

  7. 77 FR 37862 - Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ...; NIOSH-258] Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance... open-circuit self-contained breathing apparatus (OC- SCBA) remaining service-life indicators... ``Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance...

  8. Halitosis

    MedlinePlus

    ... can also affect your breath. Common examples of foods and beverages that may cause bad breath include onions, garlic, ... and vegetables every day. Eat less meat. Avoid foods that cause you to have bad breath. Also try to avoid alcoholic beverages, which often cause bad breath. Avoid using tobacco ...

  9. Breathing metabolic simulator

    NASA Technical Reports Server (NTRS)

    Bartlett, R. G.; Hendricks, C. M.; Morison, W. B.

    1972-01-01

    The development of a breathing metabolic simulator (BMS) is reported. This BMS simulates all of the breathing and metabolic parameters required for complete evaluation and test of life support and resuscitation equipment. It is also useful for calibrating and validating mechanical and gaseous pulmonary function test procedures. Breathing rate, breathing depth, breath velocity contour, oxygen uptake, and carbon dioxide release are all variable over wide ranges simulating conditions from sleep to hard work with respiratory exchange ratios covering the range from hypoventilation. In addition, all of these parameters are remotely controllable to facilitate use of the device in hostile or remote environments. The exhaled breath is also maintained at body temperature and a high humidity. The simulation is accurate to the extent of having a variable functional residual capacity independent of other parameters.

  10. Prolonged dry apnoea: effects on brain activity and physiological functions in breath-hold divers and non-divers.

    PubMed

    Ratmanova, Patricia; Semenyuk, Roxana; Popov, Daniil; Kuznetsov, Sergey; Zelenkova, Irina; Napalkov, Dmitry; Vinogradova, Olga

    2016-07-01

    The aim of the study was to investigate the effects of voluntary breath-holding on brain activity and physiological functions. We hypothesised that prolonged apnoea would trigger cerebral hypoxia, resulting in a decrease of brain performance; and the apnoea's effects would be more pronounced in breath-hold divers. Trained breath-hold divers and non-divers performed maximal dry breath-holdings. Lung volume, alveolar partial pressures of O2 and CO2, attention and anxiety levels were estimated. Heart rate, blood pressure, arterial blood oxygenation, brain tissue oxygenation, EEG, and DC potential were monitored continuously during breath-holding. There were a few significant changes in electrical brain activity caused by prolonged apnoea. Brain tissue oxygenation index and DC potential were relatively stable up to the end of the apnoea in breath-hold divers and non-divers. We also did not observe any decrease of attention level or speed of processing immediately after breath-holding. Interestingly, trained breath-hold divers had some peculiarities in EEG activity at resting state (before any breath-holding): non-spindled, sharpened alpha rhythm; slowed-down alpha with the frequency nearer to the theta band; and untypical spatial pattern of alpha activity. Our findings contradicted the primary hypothesis. Apnoea up to 5 min does not lead to notable cerebral hypoxia or a decrease of brain performance in either breath-hold divers or non-divers. It seems to be the result of the compensatory mechanisms similar to the diving response aimed at centralising blood circulation and reducing peripheral O2 uptake. Adaptive changes during apnoea are much more prominent in trained breath-hold divers.

  11. Deep breathing exercises with positive expiratory pressure in patients with multiple sclerosis - a randomized controlled trial.

    PubMed

    Westerdahl, Elisabeth; Wittrin, Anna; Kånåhols, Margareta; Gunnarsson, Martin; Nilsagård, Ylva

    2016-11-01

    Breathing exercises with positive expiratory pressure are often recommended to patients with advanced neurological deficits, but the potential benefit in multiple sclerosis (MS) patients with mild and moderate symptoms has not yet been investigated in randomized controlled trials. To study the effects of 2 months of home-based breathing exercises for patients with mild to moderate MS on respiratory muscle strength, lung function, and subjective breathing and health status outcomes. Forty-eight patients with MS according to the revised McDonald criteria were enrolled in a randomized controlled trial. Patients performing breathing exercises (n = 23) were compared with a control group (n = 25) performing no breathing exercises. The breathing exercises were performed with a positive expiratory pressure device (10-15 cmH 2 O) and consisted of 30 slow deep breaths performed twice a day for 2 months. Respiratory muscle strength (maximal inspiratory and expiratory pressure at the mouth), spirometry, oxygenation, thoracic excursion, subjective perceptions of breathing and self-reported health status were evaluated before and after the intervention period. Following the intervention, there was a significant difference between the breathing group and the control group regarding the relative change in lung function, favoring the breathing group (vital capacity: P < 0.043; forced vital capacity: P < 0.025). There were no other significant differences between the groups. Breathing exercises may be beneficial in patients with mild to moderate stages of MS. However, the clinical significance needs to be clarified, and it remains to be seen whether a sustainable effect in delaying the development of respiratory dysfunction in MS can be obtained. © 2015 The Authors. The Clinical Respiratory Journal published by John Wiley & Sons Ltd.

  12. Comparison of the heart and breathing rate of acutely ill medical patients recorded by nursing staff with those measured over 5 min by a piezoelectric belt and ECG monitor at the time of admission to hospital.

    PubMed

    Kellett, John; Li, Min; Rasool, Shahzeb; Green, Geoffrey C; Seely, Andrew

    2011-11-01

    Heart and breathing rates are predictors of disease severity and of a poor outcome. However, few reports have compared their machine measurements with traditional manual methods. A small rural Irish hospital. The heart and breathing rates of 377 acutely ill medical patients (mean age 68.3 SD 16.8 years) recorded by nursing staff at the time of admission to hospital was compared with those measured over 5 min by a piezoelectric belt and ECG monitor (the BT16 acquisition system). The mean breathing rate measured by the nursing staff (20.9 SD 4.8 breaths per min) and that measured by the BT16 piezoelectric belt (19.9 SD 4.5 breaths per min) were significantly different (p 0.004), as were the nurse and BT16 measured heart rates (85.4 SD 21.3 vs. 81.2 SD 18.7, p 0.004), and the correlation coefficient between the two methods of breathing and heart rate measurement were low. Nurse measured breathing rate measurements were clustered around rates of 18, 20 and 22 breaths per min. Unlike those obtained by nurses, BT16 measured heart and breathing rates were shown by logistic regression to be independent predictors of in-hospital mortality. There is a poor correlation between breathing and heart rates measured by traditional methods and those obtained by the BT16 device. BT16 derived breathing and heart rates, but not those measured manually, were independent predictors of in-hospital mortality. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  13. Effects of breathing exercises on breathing patterns in obese and non-obese subjects.

    PubMed

    Olsén, M F; Lönroth, H; Bake, B

    1999-05-01

    Chest physiotherapy in connection with abdominal surgery includes different deep-breathing exercises to prevent post-operative pulmonary complications. The therapy is effective in preventing pulmonary complications, especially in high-risk patients such as obese persons. The mechanisms behind the effect is unclear, but part of the effect may be explained by the changes in breathing patterns. The aim of this study was therefore to describe and to analyse the breathing patterns in obese and non-obese subjects during three different breathing techniques frequently used in the treatment of post-operative patients. Twenty-one severely obese [body mass index (BMI) > 40] and 21 non-obese (BMI 19-25) subjects were studied. All persons denied having any lung disease and were non-smokers. The breathing techniques investigated were: deep breaths without any resistance (DB), positive expiratory pressure (PEP) with an airway resistance of approximately +15 cmH2O (1.5 kPa) during expiration, inspiratory resistance positive expiratory pressure (IR-PEP) with a pressure of approximately -10 cmH2O (-1.0 kPa) during inspiration. Expiratory resistance as for PEP. Volume against time was monitored while the subjects were sitting in a body plethysmograph. Variables for volume and flow during the breathing cycle were determined. Tidal volume and alveolar ventilation were highest during DB, and peak inspiratory volume was significantly higher than during PEP and IR-PEP in the group of obese subjects. The breathing cycles were prolonged in all techniques but were most prolonged in PEP and IR-PEP. The functional residual capacity (FRC) was significantly lower during DB than during PEP and IR-PEP in the group of obese subjects. FRC as determined within 2 min of finishing each breathing technique was identical to before the breathing manoeuvres.

  14. Autonomic control of post-air-breathing tachycardia in Clarias gariepinus (Teleostei: Clariidae).

    PubMed

    Teixeira, Mariana Teodoro; Armelin, Vinicius Araújo; Abe, Augusto Shinya; Rantin, Francisco Tadeu; Florindo, Luiz Henrique

    2015-08-01

    The African catfish (Clarias gariepinus) is a teleost with bimodal respiration that utilizes a paired suprabranchial chamber located in the gill cavity as an air-breathing organ. Like all air-breathing fishes studied to date, the African catfish exhibits pronounced changes in heart rate (f H) that are associated with air-breathing events. We acquired f H, gill-breathing frequency (f G) and air-breathing frequency (f AB) in situations that require or do not require air breathing (during normoxia and hypoxia), and we assessed the autonomic control of post-air-breathing tachycardia using an infusion of the β-adrenergic antagonist propranolol and the muscarinic cholinergic antagonist atropine. During normoxia, C. gariepinus presented low f AB (1.85 ± 0.73 AB h(-1)) and a constant f G (43.16 ± 1.74 breaths min(-1)). During non-critical hypoxia (PO2 = 60 mmHg), f AB in the African catfish increased to 5.42 ± 1.19 AB h(-1) and f G decreased to 39.12 ± 1.58 breaths min(-1). During critical hypoxia (PO2 = 20 mmHg), f AB increased to 7.4 ± 1.39 AB h(-1) and f G decreased to 34.97 ± 1.78 breaths min(-1). These results were expected for a facultative air breather. Each air breath (AB) was followed by a brief but significant tachycardia, which in the critical hypoxia trials, reached a maximum of 143 % of the pre-AB f H values of untreated animals. Pharmacological blockade allowed the calculation of cardiac autonomic tones, which showed that post-AB tachycardia is predominantly regulated by the parasympathetic subdivision of the autonomic nervous system.

  15. Dosimetric Considerations in Respiratory-Gated Deep Inspiration Breath-Hold for Left Breast Irradiation.

    PubMed

    Walston, Steve; Quick, Allison M; Kuhn, Karla; Rong, Yi

    2017-02-01

    To present our clinical workflow of incorporating AlignRT for left breast deep inspiration breath-hold treatments and the dosimetric considerations with the deep inspiration breath-hold protocol. Patients with stage I to III left-sided breast cancer who underwent lumpectomy or mastectomy were considered candidates for deep inspiration breath-hold technique for their external beam radiation therapy. Treatment plans were created on both free-breathing and deep inspiration breath-hold computed tomography for each patient to determine whether deep inspiration breath-hold was beneficial based on dosimetric comparison. The AlignRT system was used for patient setup and monitoring. Dosimetric measurements and their correlation with chest wall excursion and increase in left lung volume were studied for free-breathing and deep inspiration breath-hold plans. Deep inspiration breath-hold plans had significantly increased chest wall excursion when compared with free breathing. This change in geometry resulted in reduced mean and maximum heart dose but did not impact lung V 20 or mean dose. The correlation between chest wall excursion and absolute reduction in heart or lung dose was found to be nonsignificant, but correlation between left lung volume and heart dose showed a linear association. It was also identified that higher levels of chest wall excursion may paradoxically increase heart or lung dose. Reduction in heart dose can be achieved for many left-sided breast and chest wall patients using deep inspiration breath-hold. Chest wall excursion as well as left lung volume did not correlate with reduction in heart dose, and it remains to be determined what metric will provide the most optimal and reliable dosimetric advantage.

  16. SU-E-J-158: Audiovisual Biofeedback Reduces Image Artefacts in 4DCT: A Digital Phantom Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pollock, S; Kipritidis, J; Lee, D

    2015-06-15

    Purpose: Irregular breathing motion has a deleterious impact on 4DCT image quality. The breathing guidance system: audiovisual biofeedback (AVB) is designed to improve breathing regularity, however, its impact on 4DCT image quality has yet to be quantified. The purpose of this study was to quantify the impact of AVB on thoracic 4DCT image quality by utilizing the digital eXtended Cardiac Torso (XCAT) phantom driven by lung tumor motion patterns. Methods: 2D tumor motion obtained from 4 lung cancer patients under two breathing conditions (i) without breathing guidance (free breathing), and (ii) with guidance (AVB). There were two breathing sessions, yieldingmore » 8 tumor motion traces. This tumor motion was synchronized with the XCAT phantom to simulate 4DCT acquisitions under two acquisition modes: (1) cine mode, and (2) prospective respiratory-gated mode. Motion regularity was quantified by the root mean square error (RMSE) of displacement. The number of artefacts was visually assessed for each 4DCT and summed up for each breathing condition. Inter-session anatomic reproducibility was quantified by the mean absolute difference (MAD) between the Session 1 4DCT and Session 2 4DCT. Results: AVB improved tumor motion regularity by 30%. In cine mode, the number of artefacts was reduced from 61 in free breathing to 40 with AVB, in addition to AVB reducing the MAD by 34%. In gated mode, the number of artefacts was reduced from 63 in free breathing to 51 with AVB, in addition to AVB reducing the MAD by 23%. Conclusion: This was the first study to compare the impact of breathing guidance on 4DCT image quality compared to free breathing, with AVB reducing the amount of artefacts present in 4DCT images in addition to improving inter-session anatomic reproducibility. Results thus far suggest that breathing guidance interventions could have implications for improving radiotherapy treatment planning and interfraction reproducibility.« less

  17. 78 FR 52563 - Certain Sleep-Disordered Breathing Treatment Systems and Components Thereof; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-23

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-890] Certain Sleep-Disordered Breathing... certain sleep- disordered breathing treatment systems and components thereof by reason of infringement of... after importation of certain sleep- disordered breathing treatment systems and components thereof that...

  18. VOLATILE ORGANIC COMPOUNDS AS BREATH BIOMARKERS FOR ACTIVE AND PASSIVE SMOKING

    EPA Science Inventory

    Real-time breath measurement technology was used to investigate the suitability of some volatile organic compounds (VOCs) to serve as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to toba...

  19. 75 FR 61386 - Emergency Escape Breathing Apparatus Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ...-0044, Notice No. 1] RIN 2130-AC14 Emergency Escape Breathing Apparatus Standards AGENCY: Federal... breathing apparatus (EEBA) to the members of the train crew and certain other employees while they are... EEBA--emergency escape breathing apparatus FRA--Federal Railroad Administration FRSA--the former...

  20. The glucose breath test: a diagnostic test for small bowel stricture(s) in Crohn's disease.

    PubMed

    Mishkin, Daniel; Boston, Francis M; Blank, David; Yalovsky, Morty; Mishkin, Seymour

    2002-03-01

    The aim of this study was to determine whether an indirect noninvasive indicator of proximal bacterial overgrowth, the glucose breath test, was of diagnostic value in inflammatory bowel disease. Twenty four of 71 Crohn's disease patients tested had a positive glucose breath test. No statistical conclusions could be drawn between the Crohn's disease activity index and glucose breath test status. Of patients with radiologic evidence of small bowel stricture(s), 96.0% had a positive glucose breath test, while only one of 46 negative glucose breath test patients had a stricture. The positive and negative predictive values for a positive glucose breath test as an indicator of stricture formation were 96.0% and 97.8%, respectively. This correlation was not altered in Crohn's disease patients with fistulae or status postresection of the terminal ileum. The data in ulcerative colitis were nondiagnostic. In conclusion, the glucose breath test appears to be an accurate noninvasive inexpensive diagnostic test for small bowel stricture(s) and secondary bacterial overgrowth in Crohn's disease.

  1. Breathing Maneuvers as a Vasoactive Stimulus for Detecting Inducible Myocardial Ischemia – An Experimental Cardiovascular Magnetic Resonance Study

    PubMed Central

    Fischer, Kady; Guensch, Dominik P; Shie, Nancy; Lebel, Julie; Friedrich, Matthias G

    2016-01-01

    Background Breathing maneuvers can elicit a similar vascular response as vasodilatory agents like adenosine; yet, their potential diagnostic utility in the presence of coronary artery stenosis is unknown. The objective of the study is to investigate if breathing maneuvers can non-invasively detect inducible ischemia in an experimental animal model when the myocardium is imaged with oxygenation-sensitive cardiovascular magnetic resonance (OS-CMR). Methods and Findings In 11 anesthetised swine with experimentally induced significant stenosis (fractional flow reserve <0.75) of the left anterior descending coronary artery (LAD) and 9 control animals, OS-CMR at 3T was performed during two different breathing maneuvers, a long breath-hold; and a combined maneuver of 60s of hyperventilation followed by a long breath-hold. The resulting change of myocardial oxygenation was compared to the invasive measurements of coronary blood flow, blood gases, and oxygen extraction. In control animals, all breathing maneuvers could significantly alter coronary blood flow as hyperventilation decreased coronary blood flow by 34±23%. A long breath-hold alone led to an increase of 97±88%, while the increase was 346±327% (p<0.001), when the long breath-hold was performed after hyperventilation. In stenosis animals, the coronary blood flow response was attenuated after both hyperventilation and the following breath-hold. This was matched by the observed oxygenation response as breath-holds following hyperventilation consistently yielded a significant difference in the signal of the MRI images between the perfusion territory of the stenosis LAD and remote myocardium. There was no difference between the coronary territories during the other breathing maneuvers or in the control group at any point. Conclusion In an experimental animal model, the response to a combined breathing maneuver of hyperventilation with subsequent breath-holding is blunted in myocardium subject to significant coronary artery stenosis. This maneuver may allow for detecting severe coronary artery stenosis and have a significant clinical potential as a non-pharmacological method for diagnostic testing in patients with suspected coronary artery disease. PMID:27741282

  2. Crackle pitch and rate do not vary significantly during a single automated-auscultation session in patients with pneumonia, congestive heart failure, or interstitial pulmonary fibrosis.

    PubMed

    Vyshedskiy, Andrey; Ishikawa, Sadamu; Murphy, Raymond L H

    2011-06-01

    To determine the variability of crackle pitch and crackle rate during a single automated-auscultation session with a computerized 16-channel lung-sound analyzer. Forty-nine patients with pneumonia, 52 with congestive heart failure (CHF), and 18 with interstitial pulmonary fibrosis (IPF) performed breathing maneuvers in the following sequence: normal breathing, deep breathing, cough several times; deep breathing, vital-capacity maneuver, and deep breathing. From the auscultation recordings we measured the crackle pitch and crackle rate. Crackle pitch variability, expressed as a percentage of the average crackle pitch, was small in all patients and in all maneuvers: pneumonia 11%, CHF 11%, pulmonary fibrosis 7%. Crackle rate variability was also small: pneumonia 31%, CHF 32%, IPF 24%. Compared to the first deep-breathing maneuver (100%), the average crackle pitch did not significantly change following coughing (pneumonia 100%, CHF 103%, IPF 100%), the vital-capacity maneuver (pneumonia 100%, CHF 92%, IPF 104%), or during quiet breathing (pneumonia 97%, CHF 100%, IPF 104%). Similarly, the average crackle rate did not change significantly following coughing (pneumonia 105%, CHF 110%, IPF 90%) or the vital-capacity maneuver (pneumonia 102%, CHF 101%, IPF 99%). However, during normal breathing the crackle rate was significantly lower in the patients with pneumonia (74%, P < .001) and significantly higher in the patients with IPF (147%, P < .05) than it was during deep breathing. In patients with CHF the average crackle rate during normal breathing was not significantly different from that during the first deep-breathing maneuver (108%). Crackle pitch and rate were surprisingly stable in all 3 conditions. Neither crackle pitch nor crackle rate changed significantly from breath to breath or from one deep-breathing maneuver to another, even when the maneuvers were separated by cough or the vital-capacity maneuver. The observation that crackle rate is a reproducible measurement during one automated-auscultation session suggests that crackle rate can be used to follow the course of cardiopulmonary illnesses such as pneumonia, IPF, and CHF.

  3. The autonomic control and functional significance of the changes in heart rate associated with air breathing in the jeju, Hoplerythrinus unitaeniatus.

    PubMed

    McKenzie, D J; Campbell, H A; Taylor, E W; Micheli, M; Rantin, F T; Abe, A S

    2007-12-01

    The jeju is a teleost fish with bimodal respiration that utilizes a modified swim bladder as an air-breathing organ (ABO). Like all air-breathing fish studied to date, jeju exhibit pronounced changes in heart rate (fH) during air-breathing events, and it is believed that these may facilitate oxygen uptake (MO2) from the ABO. The current study employed power spectral analysis (PSA) of fH patterns, coupled with instantaneous respirometry, to investigate the autonomic control of these phenomena and their functional significance for the efficacy of air breathing. The jeju obtained less than 5% of total MO2 (MtO2) from air breathing in normoxia at 26 degrees C, and PSA of beat-to-beat variability in fH revealed a pattern similar to that of unimodal water-breathing fish. In deep aquatic hypoxia (water PO2)=1 kPa) the jeju increased the frequency of air breathing (fAB) tenfold and maintained MtO2 unchanged from normoxia. This was associated with a significant increase in heart rate variability (HRV), each air breath (AB) being preceded by a brief bradycardia and then followed by a brief tachycardia. These fH changes are qualitatively similar to those associated with breathing in unimodal air-breathing vertebrates. Within 20 heartbeats after the AB, however, a beat-to-beat variability in fH typical of water-breathing fish was re-established. Pharmacological blockade revealed that both adrenergic and cholinergic tone increased simultaneously prior to each AB, and then decreased after it. However, modulation of inhibitory cholinergic tone was responsible for the major proportion of HRV, including the precise beat-to-beat modulation of fH around each AB. Pharmacological blockade of all variations in fH associated with air breathing in deep hypoxia did not, however, have a significant effect upon fAB or the regulation of MtO2. Thus, the functional significance of the profound HRV during air breathing remains a mystery.

  4. Cross-correlation of heartbeat and respiration rhythms

    NASA Astrophysics Data System (ADS)

    Capurro, A.; Malta, C. P.; Diambra, L.; Contreras, P.; Migliaro, E. R.

    2005-10-01

    The cross-correlation function between respiration and heart beat interval series shows that during metronomized breathing the heart beat follows the respiration more closely than during spontaneous breathing. We reproduced the heart beat interval modulations during metronomized breathing using a biophysical model of the sinoatrial node excited by an input signal formed by the recorded respiration. In the case of spontaneous breathing, a good agreement with the experimental data was obtained only by using an input signal formed by the sum of the recorded respiration and a realization of correlated noise. Metronomized breathing refers to the situation where a subject breathes following the rhythm of a metronome.

  5. Breathing spiral waves in the chlorine dioxide-iodine-malonic acid reaction-diffusion system.

    PubMed

    Berenstein, Igal; Muñuzuri, Alberto P; Yang, Lingfa; Dolnik, Milos; Zhabotinsky, Anatol M; Epstein, Irving R

    2008-08-01

    Breathing spiral waves are observed in the oscillatory chlorine dioxide-iodine-malonic acid reaction-diffusion system. The breathing develops within established patterns of multiple spiral waves after the concentration of polyvinyl alcohol in the feeding chamber of a continuously fed, unstirred reactor is increased. The breathing period is determined by the period of bulk oscillations in the feeding chamber. Similar behavior is obtained in the Lengyel-Epstein model of this system, where small amplitude parametric forcing of spiral waves near the spiral wave frequency leads to the formation of breathing spiral waves in which the period of breathing is equal to the period of forcing.

  6. Human sinus arrhythmia as an index of vagal cardiac outflow

    NASA Technical Reports Server (NTRS)

    Eckberg, D. L.

    1983-01-01

    The human central vagal mechanisms were investigated by measuring the intervals between heartbeats during controlled breathing (at breathing intervals of 2.5-10 s and nominal tidal volumes of 1000 and 1500 ml) in six young men and women. It was found that as the breathing interval increased, the longest heart periods became longer, the shortest heart periods became shorter, and the peak-valley P-P intervals increased asymptotically. Peak-valley intervals also increased in proportion to tidal volume, although this influence was small. The phase angles between heart period changes and respiration were found to vary as linear functions of breathing interval. Heart period shortening began in inspiration at short breathing intervals and in expiration at long breathing intervals, while heart period lengthening began in early expiration at all breathing intervals studied. It is concluded that a close relationship exists between variations of respiratory depth and interval and the quantity, periodicity, and timing of vagal cardiac outflow in conscious humans. The results indicate that at usual breathing rates, phasic respiration-related changes of vagal motoneuron activity begin in expiration, progress slowly, and are incompletely expressed at fast breathing ratges.

  7. An acetone breath analyzer using cavity ringdown spectroscopy: an initial test with human subjects under various situations

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Surampudi, Anand B.

    2008-10-01

    We have developed a portable breath acetone analyzer using cavity ringdown spectroscopy (CRDS). The instrument was initially tested by measuring the absorbance of breath gases at a single wavelength (266 nm) from 32 human subjects under various conditions. A background subtraction method, implemented to obtain absorbance differences, from which an upper limit of breath acetone concentration was obtained, is described. The upper limits of breath acetone concentration in the four Type 1 diabetes (T1D) subjects, tested after a 14 h overnight fast, range from 0.80 to 3.97 parts per million by volume (ppmv), higher than the mean acetone concentration (0.49 ppmv) in non-diabetic healthy breath reported in the literature. The preliminary results show that the instrument can tell distinctive differences between the breath from individuals who are healthy and those with T1D. On-line monitoring of breath gases in healthy people post-exercise, post-meals and post-alcohol-consumption was also conducted. This exploratory study demonstrates the first CRDS-based acetone breath analyzer and its potential application for point-of-care, non-invasive, diabetic monitoring.

  8. Evaluation of the agreement of tidal breathing parameters measured simultaneously using pneumotachography and structured light plethysmography.

    PubMed

    Motamedi-Fakhr, Shayan; Iles, Richard; Barney, Anna; de Boer, Willem; Conlon, Jenny; Khalid, Amna; Wilson, Rachel C

    2017-02-01

    Structured light plethysmography (SLP) is a noncontact, noninvasive, respiratory measurement technique, which uses a structured pattern of light and two cameras to track displacement of the thoraco-abdominal wall during tidal breathing. The primary objective of this study was to examine agreement between tidal breathing parameters measured simultaneously for 45 sec using pneumotachography and SLP in a group of 20 participants with a range of respiratory patterns ("primary cohort"). To examine repeatability of the agreement, an additional 21 healthy subjects ("repeatability cohort") were measured twice during resting breathing and once during increased respiratory rate (RR). Breath-by-breath and averaged RR, inspiratory time (tI), expiratory time (tE), total breath time (tTot), tI/tE, tI/tTot, and IE50 (inspiratory to expiratory flow measured at 50% of tidal volume) were calculated. Bland-Altman plots were used to assess the agreement. In the primary cohort, breath-by-breath agreement for RR was ±1.44 breaths per minute (brpm). tI, tE, and tTot agreed to ±0.22, ±0.29, and ±0.32 sec, respectively, and tI/tE, tI/tTot, and IE50/IE50 SLP to ±0.16, ±0.05, and ±0.55, respectively. When averaged, agreement for RR was ±0.19 brpm. tI, tE, and tTot were within ±0.16, ±0.16, and ±0.07 sec, respectively, and tI/tE, tI/tTot, and IE50 were within ±0.09, ±0.03, and ±0.25, respectively. A comparison of resting breathing demonstrated that breath-by-breath and averaged agreements for all seven parameters were repeatable ( P  > 0.05). With increased RR, agreement improved for tI, tE, and tTot ( P  ≤ 0.01), did not differ for tI/tE, tI/tTot, and IE50 ( P  > 0.05) and reduced for breath-by-breath ( P  < 0.05) but not averaged RR ( P  > 0.05). © 2017 PneumaCare Limited. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rubinstein, A; Kingsley, C; Melancon, A

    Purpose: To evaluate the use of post-irradiation changes in respiratory rate and CBCT-based morphology as predictors of survival in mice. Methods: C57L/J mice underwent whole-thorax irradiation with a Co-60 beam to four different doses [0Gy (n=3), 9Gy (n=5), 11Gy (n=7), and 13Gy (n=5)] in order to induce varying levels of pneumonitis. Respiratory rate measurements, breath-hold CBCTs, and free-breathing CBCTs were acquired pre-irradiation and at six time points between two and seven months post-irradiation. For respiratory rate measurements, we developed a novel computer-vision-based technique. We recorded mice sleeping in standard laboratory cages with a 30 fps, 1080p webcam (Logitech C920). Wemore » calculated respiratory rate using corner detection and optical flow to track cyclical motion in the fur in the recorded video. Breath-hold and free-breathing CBCTs were acquired on the X-RAD225Cx system. For breathhold imaging, the mice were intubated and their breath was held at full-inhale for 20 seconds. Healthy lung tissue was delineated in the scans using auto-threshold contouring (0–0.7 g/cm{sup 3}). The volume of healthy lung was measured in each of the scans. Next, lung density was measured in a 6-mm{sup 2} ROI in a fixed anatomic location in each of the scans. Results: Day-to-day variability in respiratory rate with our technique was 13%. All metrics except for breath-hold lung volume were correlated with survival: lung density on free-breathing (r=−0.7482,p<0.01) and breath-hold images (r=−0.5864,p<0.01), free-breathing lung volume (r=0.7179,p<0.01), and respiratory rate (r= 0.6953,p<0.01). Lung density on free-breathing scans was correlated with respiratory rate (r=0.7142,p<0.01) and lung density on breath-hold scans (r=0.5543,p<0.01). One significant practical hurdle in the CBCT measurements was that at least one lobe of the lung was collapsed in 36% of free-breathing scans and 45% of breath-hold scans. Conclusion: Lung density and lung volume on free-breathing CBCTs and respiratory rate outperform breath-hold CBCT measurements as indicators for survival from radiation-induced pneumonitis. This work was partially funded by Elekta.« less

  10. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air breathing...

  11. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air breathing...

  12. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air breathing...

  13. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Air breathing equipment. 154.1852 Section 154.1852... STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing equipment. (a) The master shall ensure that a licensed officer inspects the compressed air breathing...

  14. 21 CFR 868.2375 - Breathing frequency monitor.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Breathing frequency monitor. 868.2375 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2375 Breathing frequency monitor. (a) Identification. A breathing (ventilatory) frequency monitor is a device intended to measure or monitor a patient...

  15. 46 CFR 108.635 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 108.635 Section 108...

  16. 78 FR 2618 - Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-14

    ... 0920-AA38 Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements... requirements for self-contained breathing apparatus (SCBA) remaining service-life indicators or warning devices... self-contained breathing apparatus (SCBA) used in the fire service, and a firefighters' union. A...

  17. 46 CFR 108.635 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.635 Section 108...

  18. Effects of microgravity on tissue perfusion and the efficacy of astronaut denitrogenation for EVA

    NASA Technical Reports Server (NTRS)

    Gerth, Wayne A.; Vann, Richard D.; Leatherman, Nelson E.; Feezor, Michael D.

    1987-01-01

    A potentially flight-applicable, breath-by-breath method for measuring N2 elimination from human subjects breathing 100 percent O2 for 2-3 hr periods has been developed. The present report describes this development with particular emphasis on required methodological accuracy and its achievement in view of certain properties of mass spectrometer performance. A method for the breath-by-breath analysis of errors in measured N2 elimination profiles is also described.

  19. Breathing and Relaxation

    MedlinePlus

    ... Programs Health Information Doctors & Departments Clinical Research & Science Education & Training Home Health Insights Stress & Relaxation Breathing and Relaxation Breathing and Relaxation Make ...

  20. [Periodic oscillating respiration outside of comatous stages].

    PubMed

    Jammes, Y; Delpierre, S; Zwirn, P; Nicoli, M M

    1977-04-01

    A periodic oscillating breathing was observed in 11 subjects during study of their pulmonary function. All these patients were male and more than 50 years old. A cardiovascular disease was clinically evident in eight of them. Arterial hypoxemia was found in five subjects and a light hypocapnia in three. Analysis of oscillating rhythms first, revealed unexistence of ventilatory pauses between periods of deep breaths in some subjects and secondly, showed existence of permanent or discontinuous periodic rhythms. Breath by breath changes in ventilation were essentially induced by oscillations in tidal volume. Discontinuous oscillating breathing appeared after forced maximal inspiration and this periodic rhythm was frequently associated with sights. This periodic breathing began or persisted under progressive hypoxia but disappeared under normobaric hyperoxia. These data are discussed in terms of changes in the ventilatory control system and in central regulation of breathing patterns.

  1. Paced respiration with end-expiration technique offers superior BOLD signal repeatability for breath-hold studies.

    PubMed

    Scouten, A; Schwarzbauer, C

    2008-11-01

    As a simple, non-invasive method of blood oxygenation level-dependent (BOLD) signal calibration, the breath-hold task offers considerable potential for the quantification of neuronal activity from functional magnetic resonance imaging (fMRI) measurements. With an aim to improve the precision of this calibration method, the impact of respiratory rate control on the BOLD signal achieved with the breath-hold task was investigated. In addition to self-paced breathing, three different computer-paced breathing rates were imposed during the periods between end-expiration breath-hold blocks. The resulting BOLD signal timecourses and statistical activation maps were compared in eleven healthy human subjects. Results indicate that computer-paced respiration produces a larger peak BOLD signal increase with breath-hold than self-paced breathing, in addition to lower variability between trials. This is due to the more significant post-breath-hold signal undershoot present in self-paced runs, a characteristic which confounds the definition of baseline and is difficult to accurately model. Interestingly, the specific respiratory rate imposed between breath-hold periods generally does not have a statistically significant impact on the BOLD signal change. This result can be explained by previous reports of humans adjusting their inhalation depth to compensate for changes in rate, with the end-goal of maintaining homeostatic ventilation. The advantage of using end-expiration relative to end-inspiration breath-hold is apparent in view of the high repeatability of the BOLD signal in the present study, which does not suffer from the previously reported high variability associated with uncontrolled inspiration depth when using the end-inspiration technique.

  2. Effect of hypobaric air, oxygen, heliox (50:50), or heliox (80:20) breathing on air bubbles in adipose tissue.

    PubMed

    Hyldegaard, O; Madsen, J

    2007-09-01

    The fate of bubbles formed in tissues during decompression to altitude after diving or due to accidental loss of cabin pressure during flight has only been indirectly inferred from theoretical modeling and clinical observations with noninvasive bubble-measuring techniques of intravascular bubbles. In this report we visually followed the in vivo resolution of micro-air bubbles injected into adipose tissue of anesthetized rats decompressed from 101.3 kPa to and held at 71 kPa corresponding to approximately 2.750 m above sea level, while the rats breathed air, oxygen, heliox (50:50), or heliox (80:20). During air breathing, bubbles initially grew for 30-80 min, after which they remained stable or began to shrink slowly. Oxygen breathing caused an initial growth of all bubbles for 15-85 min, after which they shrank until they disappeared from view. Bubble growth was significantly greater during breathing of oxygen compared with air and heliox breathing mixtures. During heliox (50:50) breathing, bubbles initially grew for 5-30 min, from which point they shrank until they disappeared from view. After a shift to heliox (80:20) breathing, some bubbles grew slightly for 20-30 min, then shrank until they disappeared from view. Bubble disappearance was significantly faster during breathing of oxygen and heliox mixtures compared with air. In conclusion, the present results show that oxygen breathing at 71 kPa promotes bubble growth in lipid tissue, and it is possible that breathing of heliox may be beneficial in treating decompression sickness during flight.

  3. Effects of Diaphragmatic Breathing Patterns on Balance: A Preliminary Clinical Trial.

    PubMed

    Stephens, Rylee J; Haas, Mitchell; Moore, William L; Emmil, Jordan R; Sipress, Jayson A; Williams, Alex

    The purpose of this study was to determine the feasibility of performing a larger study to determine if training in diaphragmatic breathing influences static and dynamic balance. A group of 13 healthy persons (8 men, 5 women), who were staff, faculty, or students at the University of Western States participated in an 8-week breathing and balance study using an uncontrolled clinical trial design. Participants were given a series of breathing exercises to perform weekly in the clinic and at home. Balance and breathing were assessed at the weekly clinic sessions. Breathing was evaluated with Liebenson's breathing assessment, static balance with the Modified Balance Error Scoring System, and dynamic balance with OptoGait's March in Place protocol. Improvement was noted in mean diaphragmatic breathing scores (1.3 to 2.6, P < .001), number of single-leg stance balance errors (7.1 to 3.8, P = .001), and tandem stance balance errors (3.2 to 0.9, P = .039). A decreasing error rate in single-leg stance was associated with improvement in breathing score within participants over the 8 weeks of the study (-1.4 errors/unit breathing score change, P < .001). Tandem stance performance did not reach statistical significance (-0.5 error/unit change, P = .118). Dynamic balance was insensitive to balance change, being error free for all participants throughout the study. This proof-of-concept study indicated that promotion of a costal-diaphragmatic breathing pattern may be associated with improvement in balance and suggests that a study of this phenomenon using an experimental design is feasible. Copyright © 2017. Published by Elsevier Inc.

  4. Off-line breath acetone analysis in critical illness.

    PubMed

    Sturney, S C; Storer, M K; Shaw, G M; Shaw, D E; Epton, M J

    2013-09-01

    Analysis of breath acetone could be useful in the Intensive Care Unit (ICU) setting to monitor evidence of starvation and metabolic stress. The aims of this study were to examine the relationship between acetone concentrations in breath and blood in critical illness, to explore any changes in breath acetone concentration over time and correlate these with clinical features. Consecutive patients, ventilated on controlled modes in a mixed ICU, with stress hyperglycaemia requiring insulin therapy and/or new pulmonary infiltrates on chest radiograph were recruited. Once daily, triplicate end-tidal breath samples were collected and analysed off-line by selected ion flow tube mass spectrometry (SIFT-MS). Thirty-two patients were recruited (20 males), median age 61.5 years (range 26-85 years). The median breath acetone concentration of all samples was 853 ppb (range 162-11 375 ppb) collected over a median of 3 days (range 1-8). There was a trend towards a reduction in breath acetone concentration over time. Relationships were seen between breath acetone and arterial acetone (rs = 0.64, p < 0.0001) and arterial beta-hydroxybutyrate (rs = 0.52, p < 0.0001) concentrations. Changes in breath acetone concentration over time corresponded to changes in arterial acetone concentration. Some patients remained ketotic despite insulin therapy and normal arterial glucose concentrations. This is the first study to look at breath acetone concentration in ICU patients for up to 8 days. Breath acetone concentration may be used as a surrogate for arterial acetone concentration, which may in future have a role in the modulation of insulin and feeding in critical illness.

  5. Effects of forced deep breathing on blood flow velocity in the femoral vein: Developing a new physical prophylaxis for deep vein thrombosis in patients with plaster cast immobilization of the lower limb.

    PubMed

    Nakanishi, Keisuke; Takahira, Naonobu; Sakamoto, Miki; Yamaoka-Tojo, Minako; Katagiri, Masato; Kitagawa, Jun

    2018-02-01

    Patients with plaster cast immobilization of the lower limb have an estimated symptomatic venous thromboembolism rate of 5.5%. However, there is currently no practical physical prophylaxis for deep-vein thrombosis (DVT). The objective of this study was to examine the effects of forced deep breathing on peak blood velocity in the superficial femoral vein (PBVFV), which is a surrogate measure of the efficacy of thromboprophylaxis against DVT, in patients with plaster cast immobilization of the lower limb. Nine young males and 18 elderly males were recruited. We immobilized the right lower limb of each subject with a plaster splint and measured PBVFV during forced deep breathing in supine and sitting positions. In all subjects, PBVFV during forced deep breathing in both positions was significantly higher than at rest. There was no significant difference in the PBVFV change ratio for three breathing rates in the sitting position for the young subjects (15breaths/min: 415%, 5breaths/min: 475%, 3breaths/min: 483%), whereas that for the elderly subjects at 3breaths/min (449%) was significantly higher than that at 15breaths/min (284%). Forced deep breathing significantly increased PBVFV in patients with plaster cast immobilization of the lower limb in both supine and sitting positions. Testing the efficacy and adherence in clinical contexts, and following up with the incidence rate of DVT in future studies, is necessary for the development of a new physical prophylaxis for DVT. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. [Assessment of influence of breath holding and hyperventilation on human postural stability with spectral analysis of stabilographic signal].

    PubMed

    Malakhov, M V; Makarenkova, E A; Mel'nikov, A A; Vikulov, A D

    2014-01-01

    The influence of breath holding and voluntary hyperventilation on the classic stabilometric parameters and the frequency characteristic of stabilographic signal were studied. We measured the stabilometric parameters on the force platform ("Ritm", Russia) on the healthy volunteers (n = 107) during quiet breath, voluntary hyperventilation (20 seconds) and maximal inspiratory breath holding (20 seconds). Respiratory frequency, respiratory amplitude and ventilation were estimated with strain gauge. We found that antero-posterior and medio-lateral sway amplitude and velocity as well as sway surface at breath-holding and at quiet breathing were the same, so breath holding didn't influence the postural stability. However the spectral parameters shifted to the high frequency range due to alteration of the respiratory muscles contractions during breath-holding versus quiet breath. Voluntary hyperventilation caused significant increase of all stabilographic indices that implied an impairment of postural stability, which was due to the increase of respiration frequency and amplitude. We also found that the spectral indices moved toward the high-frequency range with more pronounced degree of this shift versus breath holding. Besides, amplitudes of spectral peaks also increased. Perhaps such change of spectral indices was due to distortion of proprioceptive information because of increased excitability of nerve fibers during hyperventilation. Maximal inspiration breath holding causes strain of the postural control mechanisms that is reflected as elevation of postural sway frequency with no postural stability changes. Hyperventilation leads to the most prominent strain of balance function and decrease of steadiness that is manifested as increase of center of pressure oscillations amplitude and frequency.

  7. 3D late gadolinium enhancement in a single prolonged breath-hold using supplemental oxygenation and hyperventilation.

    PubMed

    Roujol, Sébastien; Basha, Tamer A; Akçakaya, Mehmet; Foppa, Murilo; Chan, Raymond H; Kissinger, Kraig V; Goddu, Beth; Berg, Sophie; Manning, Warren J; Nezafat, Reza

    2014-09-01

    To evaluate the feasibility of three-dimensional (3D) single breath-hold late gadolinium enhancement (LGE) of the left ventricle (LV) using supplemental oxygen and hyperventilation and compressed-sensing acceleration. Breath-hold metrics [breath-hold duration, diaphragmatic/LV position drift, and maximum variation of R wave to R wave (RR) interval] without and with supplemental oxygen and hyperventilation were assessed in healthy adult subjects using a real-time single shot acquisition. Ten healthy subjects and 13 patients then underwent assessment of the proposed 3D breath-hold LGE acquisition (field of view = 320 × 320 × 100 mm(3) , resolution = 1.6 × 1.6 × 5.0 mm(3) , acceleration rate of 4) and a free-breathing acquisition with right hemidiaphragm navigator (NAV) respiratory gating. Semiquantitative grading of overall image quality, motion artifact, myocardial nulling, and diagnostic value was performed by consensus of two blinded observers. Supplemental oxygenation and hyperventilation increased the breath-hold duration (35 ± 11 s to 58 ± 21 s; P < 0.0125) without significant impact on diaphragmatic/LV position drift or maximum variation of RR interval (both P > 0.01). LGE images were of similar quality when compared with free-breathing acquisitions, but with reduced total scan time (85 ± 22 s to 35 ± 6 s; P < 0.001). Supplemental oxygenation and hyperventilation allow for prolonged breath-holding and enable single breath-hold 3D accelerated LGE with similar image quality as free breathing with NAV. Copyright © 2013 Wiley Periodicals, Inc.

  8. Stridor

    MedlinePlus

    Breathing sounds - abnormal; Extrathoracic airway obstruction; Wheezing - stridor ... questions: Is the abnormal breathing a high-pitched sound? Did the breathing problem start suddenly? Could the ...

  9. 77 FR 35747 - Highway Safety Programs; Conforming Products List of Evidential Breath Alcohol Measurement Devices

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-14

    ...-0061] Highway Safety Programs; Conforming Products List of Evidential Breath Alcohol Measurement... Evidential Breath Alcohol Measurement Devices dated, September 17, 1993 (58 FR 48705). DATES: Effective Date... Safety Administration (NHTSA) published the Standards for Devices to Measure Breath Alcohol (38 FR 30459...

  10. 21 CFR 868.5240 - Anesthesia breathing circuit.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Anesthesia breathing circuit. 868.5240 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5240 Anesthesia breathing circuit. (a) Identification. An anesthesia breathing circuit is a device that is intended to administer medical gases to a...

  11. 21 CFR 868.5240 - Anesthesia breathing circuit.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Anesthesia breathing circuit. 868.5240 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5240 Anesthesia breathing circuit. (a) Identification. An anesthesia breathing circuit is a device that is intended to administer medical gases to a...

  12. 21 CFR 868.2375 - Breathing frequency monitor.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Breathing frequency monitor. 868.2375 Section 868.2375 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2375 Breathing frequency monitor. (a) Identification. A breathing (ventilatory)...

  13. Breathwork as a Therapeutic Modality: An Overview for Counselors

    ERIC Educational Resources Information Center

    Young, J. Scott; Cashwell, Craig S.; Giordano, Amanda L.

    2010-01-01

    Using the breath as a vehicle for accessing psychological material is a topic rarely discussed in the counseling literature, despite the use of conscious engagement with the breath by many spiritual traditions for the purpose of personal transformation. This article describes 3 types of conscious breathing (circular breathing, conscious connected…

  14. 46 CFR 197.340 - Breathing gas supply.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Breathing gas supply. 197.340 Section 197.340 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.340 Breathing gas supply. (a) A primary breathing gas supply for surface-supplied diving must be sufficient to support the following for the...

  15. 46 CFR 197.340 - Breathing gas supply.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Breathing gas supply. 197.340 Section 197.340 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.340 Breathing gas supply. (a) A primary breathing gas supply for surface-supplied diving must be sufficient to support the following for the...

  16. 46 CFR 197.340 - Breathing gas supply.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Breathing gas supply. 197.340 Section 197.340 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.340 Breathing gas supply. (a) A primary breathing gas supply for surface-supplied diving must be sufficient to support the following for the...

  17. 46 CFR 197.340 - Breathing gas supply.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Breathing gas supply. 197.340 Section 197.340 Shipping... GENERAL PROVISIONS Commercial Diving Operations Equipment § 197.340 Breathing gas supply. (a) A primary breathing gas supply for surface-supplied diving must be sufficient to support the following for the...

  18. Oral Breathing Challenge in Participants with Vocal Attrition

    ERIC Educational Resources Information Center

    Sivasankar, Mahalakshmi; Fisher, Kimberly V.

    2003-01-01

    Vocal folds undergo osmotic challenge by mouth breathing during singing, exercising, and loud speaking. Just 15 min of obligatory oral breathing, to dry the vocal folds, increases phonation threshold pressure (P[subscript th]) and expiratory vocal effort in healthy speakers (M. Sivasankar & K. Fisher, 2002). We questioned whether oral breathing is…

  19. 46 CFR 195.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  20. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the following devices: (a) Two pressure-demand, open circuit, self-contained breathing apparatus, approved by...

  1. 46 CFR 195.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  2. 46 CFR 108.703 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 108.703 Section 108...

  3. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  4. 46 CFR 97.37-20 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 97.37-20 Section 97... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-20 Self-contained breathing apparatus. (a) Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF...

  5. 46 CFR 169.736 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  6. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the following devices: (a) Two pressure-demand, open circuit, self-contained breathing apparatus, approved by...

  7. 46 CFR 108.703 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.703 Section 108...

  8. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  9. 46 CFR 169.736 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  10. 46 CFR 97.37-20 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 97.37-20 Section 97... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-20 Self-contained breathing apparatus. (a) Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF...

  11. Functional Analysis and Intervention for Breath Holding.

    ERIC Educational Resources Information Center

    Kern, Lee; And Others

    1995-01-01

    A functional analysis of breath-holding episodes in a 7-year-old girl with severe mental retardation and Cornelia-de-Lange syndrome indicated that breath holding served an operant function, primarily to gain access to attention. Use of extinction, scheduled attention, and a picture card communication system decreased breath holding. (Author/SW)

  12. 21 CFR 868.5240 - Anesthesia breathing circuit.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Anesthesia breathing circuit. 868.5240 Section 868...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5240 Anesthesia breathing circuit. (a) Identification. An anesthesia breathing circuit is a device that is intended to administer medical gases to a...

  13. Noise Reduction in Breath Sound Files Using Wavelet Transform Based Filter

    NASA Astrophysics Data System (ADS)

    Syahputra, M. F.; Situmeang, S. I. G.; Rahmat, R. F.; Budiarto, R.

    2017-04-01

    The development of science and technology in the field of healthcare increasingly provides convenience in diagnosing respiratory system problem. Recording the breath sounds is one example of these developments. Breath sounds are recorded using a digital stethoscope, and then stored in a file with sound format. This breath sounds will be analyzed by health practitioners to diagnose the symptoms of disease or illness. However, the breath sounds is not free from interference signals. Therefore, noise filter or signal interference reduction system is required so that breath sounds component which contains information signal can be clarified. In this study, we designed a filter called a wavelet transform based filter. The filter that is designed in this study is using Daubechies wavelet with four wavelet transform coefficients. Based on the testing of the ten types of breath sounds data, the data is obtained in the largest SNRdB bronchial for 74.3685 decibels.

  14. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  15. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  16. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  17. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  18. 49 CFR 219.206 - FRA access to breath test results.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false FRA access to breath test results. 219.206 Section... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONTROL OF ALCOHOL AND DRUG USE Post-Accident Toxicological Testing § 219.206 FRA access to breath test results. Documentation of breath test results must be made available...

  19. Experimental Analysis of Dampened Breathing Mode Oscillation on Hall Thruster Performance

    DTIC Science & Technology

    2013-03-01

    38 4.5 Analysis of Discharge RMS Effect on Breathing Mode Amplitude...20 xii EXPERIMENTAL ANALYSIS OF DAMPENED BREATHING MODE OSCILLATION ON HALL EFFECT THRUSTER...the large error in the data presented above prevents many conclusions from being drawn. 4.5 Analysis of Discharge RMS Effect on Breathing Mode

  20. 30 CFR 57.22315 - Self-contained breathing apparatus (V-A mines).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Self-contained breathing apparatus (V-A mines... NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22315 Self-contained breathing apparatus (V-A mines). Self-contained breathing apparatus of a duration to allow for escape from...

  1. 46 CFR 196.37-20 - Self-contained breathing apparatus and gas masks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus and gas masks. 196.37... RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-20 Self-contained breathing apparatus and gas masks. (a) Lockers or spaces containing self-contained breathing apparatus shall...

  2. 46 CFR 196.37-20 - Self-contained breathing apparatus and gas masks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus and gas masks. 196.37... RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-20 Self-contained breathing apparatus and gas masks. (a) Lockers or spaces containing self-contained breathing apparatus shall...

  3. 46 CFR 28.205 - Fireman's outfits and self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Fireman's outfits and self-contained breathing apparatus... the Aleutian Trade § 28.205 Fireman's outfits and self-contained breathing apparatus. (a) Each vessel... equipped with at least two self-contained breathing apparatuses. (c) A fireman's outfit must consist of one...

  4. 30 CFR 57.22315 - Self-contained breathing apparatus (V-A mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Self-contained breathing apparatus (V-A mines... NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22315 Self-contained breathing apparatus (V-A mines). Self-contained breathing apparatus of a duration to allow for escape from...

  5. 46 CFR 28.205 - Fireman's outfits and self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fireman's outfits and self-contained breathing apparatus... the Aleutian Trade § 28.205 Fireman's outfits and self-contained breathing apparatus. (a) Each vessel... equipped with at least two self-contained breathing apparatuses. (c) A fireman's outfit must consist of one...

  6. Drinking influences exhaled breath condensate acidity.

    PubMed

    Kullmann, Tamás; Barta, Imre; Antus, Balázs; Horváth, Ildikó

    2008-01-01

    Exhaled breath condensate analysis is a developing method for investigating airway pathology. Impact of food and drink on breath condensate composition has not been systematically addressed. The aim of the study was to follow exhaled breath condensate pH after drinking an acidic and a neutral beverage. Breath condensate, capillary blood, and urine of 12 healthy volunteers were collected before and after drinking either 1 l of coke or 1 l of mineral water. The pH of each sample was determined with a blood gas analyzer. The mean difference between the pH of two breath condensate samples collected within 15 min before drinking was 0.13+/-0.03. Condensate pH decreased significantly from 6.29+/-0.02 to 6.24+/-0.02 (p<0.03) after drinking coke and from 6.37+/-0.03 to 6.22+/-0.04 (p<0.003) after drinking water. Drinking coke induced significant changes in blood and urine pH as well. Drinking influences exhaled breath condensate composition and may contribute to the variability of exhaled breath condensate pH.

  7. Qualitative assessment of contrast-enhanced magnetic resonance angiography using breath-hold and non-breath-hold techniques in the portal venous system

    NASA Astrophysics Data System (ADS)

    Goo, Eun-Hoe; Kim, Sun-Ju; Dong, Kyung-Rae; Kim, Kwang-Choul; Chung, Woon-Kwan

    2016-09-01

    The purpose of this study is to evaluate the image quality in delineation of the portal venous systems with two different methods, breath-hold and non-breath-hold by using the 3D FLASH sequence. We used a 1.5 T system to obtain magnetic resonance(MR)images. Arterial and portal phase 3D FLASH images were obtained with breath-hold after a bolus injection of GD-DOTA. The detection of PVS on the MR angiograms was classified into three grades. First, the angiograms of the breath-hold method showed well the portal vein, the splenic vein and the superior mesenteric vein systems in 13 of 15 patients (86%) and the inferior mesenteric vein system in 6 of 15 patients (40%), Second, MR angiograms of the non-breath-hold method demonstrated the PVS and the SMV in 12 of 15 patients (80%) and the IMV in 5 of 15 patients (33%). Our study showed contrast-enhanced 3D FLASH MR angiography, together with the breath-hold technique, may provide reliable and accurate information on the portal venous system.

  8. Influence of breathing resistance of heat and moisture exchangers on tracheal climate and breathing pattern in laryngectomized individuals.

    PubMed

    Scheenstra, Renske J; Muller, Sara H; Vincent, Andrew; Sinaasappel, Michiel; Hilgers, Frans J M

    2010-08-01

    The aim of this study was to determine the influence of breathing resistance of heat and moisture exchangers (HMEs) on endotracheal climate and breathing pattern. Endotracheal temperature and humidity and tidal volumes were measured in 11 laryngectomized patients with a regularly used HME with "standard" breathing resistance (Provox Normal HME; R-HME), a low breathing-resistance HME (Provox HiFlow HME; L-HME), and without HME. Both R-HME and L-HME increased end-inspiratory humidity (+5.8 and 4.7 mgH(2)O/L, respectively), decreased end-inspiratory temperature (-1.6 and -1.0 degrees C, respectively), and prolonged the exhalation breath length to approximately 0.5 seconds. The R-HME significantly enlarged tidal volumes (0.07 L; p < .05). Both HMEs significantly improve tracheal climate. The R-HME has better moistening properties and a small but significant positive effect on tidal volume. Therefore, if the higher resistance is tolerated, the R-HME is the preferred pulmonary rehabilitation device. The L-HME is indicated if lower breathing resistance is required. 2009 Wiley Periodicals, Inc. Head Neck, 2010.

  9. Neurophysiological study on the effect of various short durations of deep breathing: A randomized controlled trial.

    PubMed

    Cheng, Kok Suen; Han, Ray P S; Lee, Poh Foong

    2018-02-01

    The study aims to study the effects of short duration deep breathing on the EEG power with topography based on parallel group randomized controlled trial design which was lacking in prior reports. 50 participants were split into 4 groups: control (CONT), deep breathing (DB) for 5 (DB5), 7 (DB7), and 9 (DB9) minutes. EEG recordings were obtained during baseline, deep breathing session, after deep breathing, and a follow-up session after 7 days of consecutive practice. Frontal theta power of DB5 and DB9 was significantly larger than that of CONT after the deep breathing session (p = 0.027 and p = 0.006, respectively) and the profound finding showed that the theta topography obtained a central-focused distribution for DB7 and DB9. The result obtained was consistent with previous literature, albeit for certain deep breathing durations only, indicating a possible linkage between the deep breathing duration and the neurophysiology of the brain. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Applications of external cavity diode laser-based technique to noninvasive clinical diagnosis using expired breath ammonia analysis: chronic kidney disease, epilepsy

    NASA Astrophysics Data System (ADS)

    Bayrakli, Ismail; Turkmen, Aysenur; Akman, Hatice; Sezer, M. Tugrul; Kutluhan, Suleyman

    2016-08-01

    An external cavity laser (ECL)-based off-axis cavity-enhanced absorption spectroscopy was applied to noninvasive clinical diagnosis using expired breath ammonia analysis: (1) the correlation between breath ammonia levels and blood parameters related to chronic kidney disease (CKD) was investigated and (2) the relationship between breath ammonia levels and blood concentrations of valproic acid (VAP) was studied. The concentrations of breath ammonia in 15 healthy volunteers, 10 epilepsy patients (before and after taking VAP), and 27 patients with different stages of CKD were examined. The range of breath ammonia levels was 120 to 530 ppb for healthy subjects and 710 to 10,400 ppb for patients with CKD. There was a statistically significant positive correlation between breath ammonia concentrations and urea, blood urea nitrogen, creatinine, or estimated glomerular filtration rate in 27 patients. It was demonstrated that taking VAP gave rise to increasing breath ammonia levels. A statistically significant difference was found between the levels of exhaled ammonia (NH3) in healthy subjects and in patients with epilepsy before and after taking VAP. The results suggest that our breath ammonia measurement system has great potential as an easy, noninvasive, real-time, and continuous monitor of the clinical parameters related to epilepsy and CKD.

  11. Noninvasive detection of lung cancer using exhaled breath

    PubMed Central

    Fu, Xiao-An; Li, Mingxiao; Knipp, Ralph J; Nantz, Michael H; Bousamra, Michael

    2014-01-01

    Early detection of lung cancer is a key factor for increasing the survival rates of lung cancer patients. The analysis of exhaled breath is promising as a noninvasive diagnostic tool for diagnosis of lung cancer. We demonstrate the quantitative analysis of carbonyl volatile organic compounds (VOCs) and identification of lung cancer VOC markers in exhaled breath using unique silicon microreactor technology. The microreactor consists of thousands of micropillars coated with an ammonium aminooxy salt for capture of carbonyl VOCs in exhaled breath by means of oximation reactions. Captured aminooxy-VOC adducts are analyzed by nanoelectrospray Fourier transform-ion cyclotron resonance (FT-ICR) mass spectrometry (MS). The concentrations of 2-butanone, 2-hydroxyacetaldehyde, 3-hydroxy-2-butanone, and 4-hydroxyhexenal (4-HHE) in the exhaled breath of lung cancer patients (n = 97) were significantly higher than in the exhaled breath of healthy smoker and nonsmoker controls (n = 88) and patients with benign pulmonary nodules (n = 32). The concentration of 2-butanone in exhaled breath of patients (n = 51) with stages II though IV non–small cell lung cancer (NSCLC) was significantly higher than in exhaled breath of patients with stage I (n = 34). The carbonyl VOC profile in exhaled breath determined using this new silicon microreactor technology provides for the noninvasive detection of lung cancer. PMID:24402867

  12. Breath in the technoscientific imaginary.

    PubMed

    Rose, Arthur

    2016-12-01

    Breath has a realist function in most artistic media. It serves to remind the reader, the viewer or the spectator of the exigencies of the body. In science fiction (SF) literature and films, breath is often a plot device for human encounters with otherness, either with alien peoples, who may not breathe oxygen, or environments, where there may not be oxygen to breathe. But while there is a technoscientific quality to breath in SF, especially in its attention to physiological systems, concentrating on the technoscientific threatens to occlude other, more affective aspects raised by the literature. In order to supplement the tendency to read SF as a succession of technoscientific accounts of bodily experience, this paper recalls how SF texts draw attention to the affective, non-scientific qualities of breath, both as a metonym for life and as a metaphor for anticipation. Through an engagement with diverse examples from SF literature and films, this article considers the tension between technoscientific and affective responses to breath in order to demonstrate breath's co-determinacy in SF's blending of scientific and artistic discourses. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. [Effects of breathing exercises on breathing pattern and thoracoabdominal motion after gastroplasty].

    PubMed

    Tomich, Georgia Miranda; França, Danielle Corrêa; Diniz, Marco Túlio Costa; Britto, Raquel Rodrigues; Sampaio, Rosana Ferreira; Parreira, Verônica Franco

    2010-01-01

    To evaluate breathing pattern and thoracoabdominal motion during breathing exercises. Twenty-four patients with class II or III obesity (18 women; 6 men) were studied on the second postoperative day after gastroplasty. The mean age was 37 +/- 11 years, and the mean BMI was 44 +/- 3 kg/m(2). Diaphragmatic breathing, incentive spirometry with a flow-oriented device and incentive spirometry with a volume-oriented device were performed in random order. Respiratory inductive plethysmography was used in order to measure respiratory variables and thoracoabdominal motion. Comparisons among the three exercises showed significant differences: tidal volume was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing; the respiratory rate was lower during incentive spirometry with the volume-oriented device than during incentive spirometry with the flow-oriented device; and minute ventilation was higher during incentive spirometry (with the flow-oriented device or with the volume-oriented device) than during diaphragmatic breathing. Rib cage motion did not vary during breathing exercises, although there was an increase in thoracoabdominal asynchrony, especially during incentive spirometry with the flow-oriented device. Among the breathing exercises evaluated, incentive spirometry with the volume-oriented device provided the best results, because it allowed slower, deeper inhalation.

  14. Design of a breath analysis system for diabetes screening and blood glucose level prediction.

    PubMed

    Yan, Ke; Zhang, David; Wu, Darong; Wei, Hua; Lu, Guangming

    2014-11-01

    It has been reported that concentrations of several biomarkers in diabetics' breath show significant difference from those in healthy people's breath. Concentrations of some biomarkers are also correlated with the blood glucose levels (BGLs) of diabetics. Therefore, it is possible to screen for diabetes and predict BGLs by analyzing one's breath. In this paper, we describe the design of a novel breath analysis system for this purpose. The system uses carefully selected chemical sensors to detect biomarkers in breath. Common interferential factors, including humidity and the ratio of alveolar air in breath, are compensated or handled in the algorithm. Considering the intersubject variance of the components in breath, we build subject-specific prediction models to improve the accuracy of BGL prediction. A total of 295 breath samples from healthy subjects and 279 samples from diabetic subjects were collected to evaluate the performance of the system. The sensitivity and specificity of diabetes screening are 91.51% and 90.77%, respectively. The mean relative absolute error for BGL prediction is 21.7%. Experiments show that the system is effective and that the strategies adopted in the system can improve its accuracy. The system potentially provides a noninvasive and convenient method for diabetes screening and BGL monitoring as an adjunct to the standard criteria.

  15. Breath Group Analysis for Reading and Spontaneous Speech in Healthy Adults

    PubMed Central

    Wang, Yu-Tsai; Green, Jordan R.; Nip, Ignatius S.B.; Kent, Ray D.; Kent, Jane Finley

    2010-01-01

    Aims The breath group can serve as a functional unit to define temporal and fundamental frequency (f0) features in continuous speech. These features of the breath group are determined by the physiologic, linguistic, and cognitive demands of communication. Reading and spontaneous speech are two speaking tasks that vary in these demands and are commonly used to evaluate speech performance for research and clinical applications. The purpose of this study is to examine differences between reading and spontaneous speech in the temporal and f0 aspects of their breath groups. Methods Sixteen participants read two passages and answered six questions while wearing a circumferentially vented mask connected to a pneumotach. The aerodynamic signal was used to identify inspiratory locations. The audio signal was used to analyze task differences in breath group structure, including temporal and f0 components. Results The main findings were that spontaneous speech task exhibited significantly more grammatically inappropriate breath group locations and longer breath group duration than did the passage reading task. Conclusion The task differences in the percentage of grammatically inadequate breath group locations and in breath group duration for healthy adult speakers partly explain the differences in cognitive-linguistic load between the passage reading and spontaneous speech. PMID:20588052

  16. Breath group analysis for reading and spontaneous speech in healthy adults.

    PubMed

    Wang, Yu-Tsai; Green, Jordan R; Nip, Ignatius S B; Kent, Ray D; Kent, Jane Finley

    2010-01-01

    The breath group can serve as a functional unit to define temporal and fundamental frequency (f0) features in continuous speech. These features of the breath group are determined by the physiologic, linguistic, and cognitive demands of communication. Reading and spontaneous speech are two speaking tasks that vary in these demands and are commonly used to evaluate speech performance for research and clinical applications. The purpose of this study is to examine differences between reading and spontaneous speech in the temporal and f0 aspects of their breath groups. Sixteen participants read two passages and answered six questions while wearing a circumferentially vented mask connected to a pneumotach. The aerodynamic signal was used to identify inspiratory locations. The audio signal was used to analyze task differences in breath group structure, including temporal and f0 components. The main findings were that spontaneous speech task exhibited significantly more grammatically inappropriate breath group locations and longer breath group duration than did the passage reading task. The task differences in the percentage of grammatically inadequate breath group locations and in breath group duration for healthy adult speakers partly explain the differences in cognitive-linguistic load between the passage reading and spontaneous speech. Copyright © 2010 S. Karger AG, Basel.

  17. New insights into sucking, swallowing and breathing central generators: A complexity analysis of rhythmic motor behaviors.

    PubMed

    Samson, Nathalie; Praud, Jean-Paul; Quenet, Brigitte; Similowski, Thomas; Straus, Christian

    2017-01-18

    Sucking, swallowing and breathing are dynamic motor behaviors. Breathing displays features of chaos-like dynamics, in particular nonlinearity and complexity, which take their source in the automatic command of breathing. In contrast, buccal/gill ventilation in amphibians is one of the rare motor behaviors that do not display nonlinear complexity. This study aimed at assessing whether sucking and swallowing would also follow nonlinear complex dynamics in the newborn lamb. Breathing movements were recorded before, during and after bottle-feeding. Sucking pressure and the integrated EMG of the thyroartenoid muscle, as an index of swallowing, were recorded during bottle-feeding. Nonlinear complexity of the whole signals was assessed through the calculation of the noise limit value (NL). Breathing and swallowing always exhibited chaos-like dynamics. The NL of breathing did not change significantly before, during or after bottle-feeding. On the other hand, sucking inconsistently and significantly less frequently than breathing exhibited a chaos-like dynamics. Therefore, the central pattern generator (CPG) that drives sucking may be functionally different from the breathing CPG. Furthermore, the analogy between buccal/gill ventilation and sucking suggests that the latter may take its phylogenetic origin in the gill ventilation CPG of the common ancestor of extant amphibians and mammals. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Measurement and prediction of indoor air quality using a breathing thermal manikin.

    PubMed

    Melikov, A; Kaczmarczyk, J

    2007-02-01

    The analyses performed in this paper reveal that a breathing thermal manikin with realistic simulation of respiration including breathing cycle, pulmonary ventilation rate, frequency and breathing mode, gas concentration, humidity and temperature of exhaled air and human body shape and surface temperature is sensitive enough to perform reliable measurement of characteristics of air as inhaled by occupants. The temperature, humidity, and pollution concentration in the inhaled air can be measured accurately with a thermal manikin without breathing simulation if they are measured at the upper lip at a distance of <0.01 m from the face. Body surface temperature, shape and posture as well as clothing insulation have impact on the measured inhaled air parameters. Proper simulation of breathing, especially of exhalation, is needed for studying the transport of exhaled air between occupants. A method for predicting air acceptability based on inhaled air parameters and known exposure-response relationships established in experiments with human subjects is suggested. Recommendations for optimal simulation of human breathing by means of a breathing thermal manikin when studying pollution concentration, temperature and humidity of the inhaled air as well as the transport of exhaled air (which may carry infectious agents) between occupants are outlined. In order to compare results obtained with breathing thermal manikins, their nose and mouth geometry should be standardized.

  19. Measurement of hepatic functional mass by means of 13C-methacetin and 13C-phenylalanine breath tests in chronic liver disease: Comparison with Child-Pugh score and serum bile acid levels

    PubMed Central

    Festi, D.; Capodicasa, S.; Sandri, L.; Colaiocco-Ferrante, L.; Staniscia, T.; Vitacolonna, E.; Vestito, A.; Simoni, P.; Mazzella, G.; Portincasa, P.; Roda, E.; Colecchia, A.

    2005-01-01

    AIM: To evaluate and compare the clinical usefulness of 13C-phenylalanine and 13C-methacetin breath tests in quantitating functional hepatic mass in patients with chronic liver disease and to further compare these results with those of conventional tests, Child-Pugh score and serum bile acid levels. METHODS: One hundred and forty patients (50 HCV- related chronic hepatitis, 90 liver cirrhosis patients) and 40 matched healthy controls were studied. Both breath test and routine liver test, serum levels of cholic and chenodeoxycholic acid conjugates were evaluated. RESULTS: Methacetin breath test, expressed as 60 min cumulative percent of oxidation, discriminated the hepatic functional capacity not only between controls and liver disease patients, but also between different categories of chronic liver disease patients. Methacetin breath test was correlated with liver function tests and serum bile acids. Furthermore, methacetin breath test, as well as serum bile acids, were highly predictive of Child-Pugh scores. The diagnostic power of phenylalanine breath test was always less than that of methacetin breath test. CONCLUSION: Methacetin breath test represents a safe and accurate diagnostic tool in the evaluation of hepatic functional mass in chronic liver disease patients. PMID:15609414

  20. From breathing to respiration.

    PubMed

    Fitting, Jean-William

    2015-01-01

    The purpose of breathing remained an enigma for a long time. The Hippocratic school described breathing patterns but did not associate breathing with the lungs. Empedocles and Plato postulated that breathing was linked to the passage of air through pores of the skin. This was refuted by Aristotle who believed that the role of breathing was to cool the heart. In Alexandria, breakthroughs were accomplished in the anatomy and physiology of the respiratory system. Later, Galen proposed an accurate description of the respiratory muscles and the mechanics of breathing. However, his heart-lung model was hampered by the traditional view of two non-communicating vascular systems - veins and arteries. After a period of stagnation in the Middle Ages, knowledge progressed with the discovery of pulmonary circulation. The comprehension of the purpose of breathing progressed by steps thanks to Boyle and Mayow among others, and culminated with the contribution of Priestley and the discovery of oxygen by Lavoisier. Only then was breathing recognized as fulfilling the purpose of respiration, or gas exchange. A century later, a controversy emerged concerning the active or passive transfer of oxygen from alveoli to the blood. August and Marie Krogh settled the dispute, showing that passive diffusion was sufficient to meet the oxygen needs. © 2014 S. Karger AG, Basel.

  1. Effect of oxygenation on breath-by-breath response of the genioglossus muscle during occlusion.

    PubMed

    Gauda, E B; Carroll, J L; McColley, S; Smith, P L

    1991-10-01

    We investigated the effect of different levels of O2 tension (hypoxia, normoxia, and hyperoxia) on the breath-by-breath onset and peak electromyographic (EMG) activity of the genioglossus (GG) muscle during a five-breath end-expiratory tracheal occlusion of 20- to 30-s duration. GG and diaphragmatic (DIA) EMG activity were measured with needle electrodes in eight anesthetized tracheotomized adult cats. In response to occlusion, the increase in the number of animals with GG EMG activity was different during hypoxia, normoxia, and hyperoxia (P = 0.003, Friedman). During hypoxia, eight of eight of the animals had GG EMG activity by the third occluded effort. In contrast, during normoxia, only four of eight and, during hyperoxia, only three of eight animals had GG EMG activity throughout the entire five-breath occlusion. Similarly, at release of the occlusion, more animals had persistent GG EMG activity on the postocclusion breaths during hypoxia than during normoxia or hyperoxia. Breath-by-breath augmentation of peak amplitude of the GG and DIA EMGs on each occluded effort was accentuated during hypoxia (P less than 0.01) and abolished during hyperoxia (P = 0.10). These results suggest that hypoxemia is a major determinant of the rapidity of onset, magnitude, and sustained activity of upper airway muscles during airway occlusion.

  2. Oral breathing challenge in participants with vocal attrition.

    PubMed

    Sivasankar, Mahalakshmi; Fisher, Kimberly V

    2003-12-01

    Vocal folds undergo osmotic challenge by mouth breathing during singing, exercising, and loud speaking. Just 15 min of obligatory oral breathing, to dry the vocal folds, increases phonation threshold pressure (Pth) and expiratory vocal effort in healthy speakers (M. Sivasankar & K. Fisher, 2002). We questioned whether oral breathing is more detrimental to phonation in healthy participants with a history of temporary vocal attrition. The effects of a 15-min oral or nasal breathing challenge on Pth and perceived expiratory vocal effort were compared for participants reporting symptoms of vocal attrition (N = 18, ages 19-38 years) and normal controls (N = 20, ages 19-33 years). Post-challenge-prechallenge differences in Pth (deltaPth) and effort (deltaEffort) revealed that oral breathing, but not nasal breathing, increased Pth (p < .001 ) and effort (p < .001) at low, comfortable, and high pitch. deltaPth was significantly greater in participants with vocal attrition than in normal controls (p < .001). Nasal breathing reduced Pth for all controls but not for all participants reporting vocal attrition. deltaPth was significantly and linearly correlated with deltaEffort (rvocal attrition = .81, p < .001; rcontrol = .84, p < .001). We speculate that the greater increases in Pth in participants reporting vocal attrition may result from delayed or inadequate compensatory response to superficial laryngeal dehydration. Obligatory oral breathing may place voice users at risk for exacerbating vocal attrition. That sol layer depletion by obligatory oral breathing increased Pth and vocal effort provides support for the role of superficial hydration in maintaining ease of phonation.

  3. Impact of endotracheal tube shortening on work of breathing in neonatal and pediatric in vitro lung models.

    PubMed

    Mohr, Rebecca; Thomas, Jörg; Cannizzaro, Vincenzo; Weiss, Markus; Schmidt, Alexander R

    2017-09-01

    Work of breathing accounts for a significant proportion of total oxygen consumption in neonates and infants. Endotracheal tube inner diameter and length significantly affect airflow resistance and thus work of breathing. While endotracheal tube shortening reduces endotracheal tube resistance, the impact on work of breathing in mechanically ventilated neonates and infants remains unknown. The objective of this in vitro study was to quantify the effect of endotracheal tube shortening on work of breathing in simulated pediatric lung settings. We hypothesized that endotracheal tube shortening significantly reduces work of breathing. We used the Active-Servo-Lung 5000 to simulate different clinical scenarios in mechanically ventilated infants and neonates under spontaneous breathing with and without pressure support. Endotracheal tube size, lung resistance, and compliance, as well as respiratory settings such as respiratory rate and tidal volume were weight and age adapted for each lung model. Work of breathing was measured before and after maximal endotracheal tube shortening and the reduction of the daily energy demand calculated. Tube shortening with and without pressure support decreased work of breathing to a maximum of 10.1% and 8.1%, respectively. As a result, the calculated reduction of total daily energy demand by endotracheal tube shortening was between 0.002% and 0.02%. In this in vitro lung model, endotracheal tube shortening had minimal effects on work of breathing. Moreover, the calculated percentage reduction of the total daily energy demand after endotracheal tube shortening was minimal. © 2017 John Wiley & Sons Ltd.

  4. Social relations and breath odour.

    PubMed

    McKeown, L

    2003-11-01

    In this retrospective qualitative study, the researcher reviewed 55 client records of The Breath Odour Clinic. The purpose was to determine if individuals attended a clinic specialised in treating oral malodour for medical or social reasons. The study focused on the psychosocial and breath odour history. Clients had agreed to the use of information for research purposes. Society uses odour as a means to define and interact with the world. The olfactory, smelling experience is intimate, emotionally charged and connects us with the world. It follows that the smell from mouth breath odour can connect or disconnect a person from their social environment and intimate relationships. How one experiences one's own body is very personal and private but also very public. Breath odour is public as it occurs within a social and cultural context and personal as it affects one's body image and self-confidence. Body image, self-image and social relations mesh, interact and impact upon each other. Breath odour is a dynamic and interactive aspect of the self-image. In addition, breath odour may be value-coded as 'bad'. In 75% of the cases reviewed, decreased self-confidence and insecurity in social and intimate relations led clients to seek treatment at the specialised breath odour clinic. Their doctor, dental hygienist or dentist had treated medical and oral conditions but not resolved their breath odour problem. When a person perceives a constant bad breath problem, she/he uses defence techniques, and may avoid social situations and social relations. This affects a person's well-being.

  5. Dataset of breath research manuscripts curated using PubMed search strings from 1995-2016.

    PubMed

    Geer Wallace, M Ariel; Pleil, Joachim D

    2018-06-01

    The data contained in this article are PubMed search strings and search string builders used to curate breath research manuscripts published from 1995-2016 and the respective number of articles found that satisfied the search requirements for selected categories. Breath sampling represents a non-invasive technique that has gained usefulness for public health, clinical, diagnostic, and environmental exposure assessment applications over the years. This data article includes search strings that were utilized to retrieve publications through the PubMed database for different breath research-related topics that were related to the analysis of exhaled breath, exhaled breath condensate (EBC), and exhaled breath aerosol (EBA) as well as the analysis of cellular headspace. Manuscripts were curated for topics including EBC, EBA, Direct MS, GC-MS, LC-MS, alcohol, and sensors. A summary of the number of papers published per year for the data retrieved using each of the search strings is also included. These data can be utilized to discern trends in the number of breath research publications in each of the different topics over time. A supplementary Appendix A containing the titles, author lists, journal names, publication dates, PMID numbers, and EntrezUID numbers for each of the journal articles curated using the finalized search strings for the seven breath research-related topics can also be found within this article. The selected manuscripts can be used to explore the impact that breath research has had on expanding the scientific knowledge in each of the investigated topics.

  6. Breathing pattern and head posture: changes in craniocervical angles.

    PubMed

    Sabatucci, A; Raffaeli, F; Mastrovincenzo, M; Luchetta, A; Giannone, A; Ciavarella, D

    2015-04-01

    The aim of this study was to observe the influence of oral breathing on head posture and to establish possible postural changes observing the variation of craniocervical angles NSL/OPT and NSL/CVT between oral breathing subjects and physiological breathing subjects. A cross-sectional study was conducted. The sample included 115 subject, 56 boys and 59 girls, 5-22-year-old. Among these, 80 were classified as oral breathers and 35 as physiological breathers. The diagnosis of oral breathing was carried out thanks to characteristic signs and symptoms evaluated on clinical examination, the analysis of characteristic X-ray images, ENT examination with active anterior rhinomanometric (AAR) test. The structural and postural analysis was carried out, calculating the craniofacial angles NSL/OPT and NSL/CVT. Both NSL/OPT and NSL/CVT appear to be significantly greater to those observed in physiological breathing patients. This means that patients who tend to breathe through the mouth rather than exclusively through the nose show a reduction of cervical lordosis and a proinclination of the head. Our study confirms that the oral breathing modifies head position. The significant increase of the craniocervical angles NSL/OPT and NSL/CVT in patients with this altered breathing pattern suggests an elevation of the head and a greater extension of the head compared with the cervical spine. So, to correct the breathing pattern early, either during childhood or during adolescence, can lead to a progressive normalization of craniofacial morphology and head posture.

  7. Aspiration tests in aqueous foam using a breathing simulator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Archuleta, M.M.

    1995-12-01

    Non-toxic aqueous foams are being developed by Sandia National Laboratories (SNL) for the National Institute of Justice (NIJ) for use in crowd control, cell extractions, and group disturbances in the criminal justice prison systems. The potential for aspiration of aqueous foam during its use and the resulting adverse effects associated with complete immersion in aqueous foam is of major concern to the NIJ when examining the effectiveness and safety of using this technology as a Less-Than-Lethal weapon. This preliminary study was designed to evaluate the maximum quantity of foam that might be aspirated by an individual following total immersion inmore » an SNL-developed aqueous foam. A.T.W. Reed Breathing simulator equipped with a 622 Silverman cam was used to simulate the aspiration of an ammonium laureth sulfate aqueous foam developed by SNL and generated at expansion ratios in the range of 500:1 to 1000:1. Although the natural instinct of an individual immersed in foam is to cover their nose and mouth with a hand or cloth, thus breaking the bubbles and decreasing the potential for aspiration, this study was performed to examine a worst case scenario where mouth breathing only was examined, and no attempt was made to block foam entry into the breathing port. Two breathing rates were examined: one that simulated a sedentary individual with a mean breathing rate of 6.27 breaths/minute, and one that simulated an agitated or heavily breathing individual with a mean breathing rate of 23.7 breaths/minute. The results of this study indicate that, if breathing in aqueous foam without movement, an air pocket forms around the nose and mouth within one minute of immersion.« less

  8. A reservoir nasal cannula improves protection given by oxygen during muscular exercise in COPD.

    PubMed

    Arlati, S; Rolo, J; Micallef, E; Sacerdoti, C; Brambilla, I

    1988-06-01

    We verified the utility of an oxygen economizer (Pendant Oxymizer) in assuring greater protection than nasal prongs against worsening of oxyhemoglobin resting desaturation (delta SaO2) induced by muscular exercise in 16 patients (ten with chronic obstructive pulmonary disease [COPD] and six with restrictive pulmonary disease). This worsening was quantified as desaturation surface accumulated within five minutes of exercise and was expressed in arbitrary units (au). Each patient carried out the same exercise three times, in a randomized fashion (breathing air or breathing supplemental oxygen [3 L/min] delivered by either nasal prongs or by oxygen economizer). In patients with obstructive disease, delta SaO2 was reduced from 38 +/- 12.0 au when they were breathing air to 18.1 +/- 11.7 au when breathing oxygen by nasal prongs (p less than 0.001) and to 10.1 +/- 9.5 au when breathing oxygen by economizer (p less than 0.001). In patients with restrictive disease, delta SaO2 was reduced from 35.6 +/- 9.9 au when breathing air to 14.9 +/- 10.2 au breathing oxygen by nasal prongs (p less than 0.01) and to 13.7 +/- 10.3 au breathing oxygen by economizer (p less than 0.01). The difference between breathing by economizer and nasal prongs was significant (paired t-test; p less than 0.01) only in patients with COPD. One explanation could lie in the different values of the respiratory rate, which was significantly greater in patients with restrictive disease (20.7 +/- 1.2 breaths per minute at rest and 25.8 +/- 1.5 with exercise) than in patients with obstructive disease (15.3 +/- 1.2 breaths per minute at rest and 20.8 +/- 1.4 with exercise).

  9. Prevalence of sleep breathing complaints reported by treatment-seeking chronic insomnia disorder patients on presentation to a sleep medical center: a preliminary report.

    PubMed

    Krakow, Barry; Ulibarri, Victor A

    2013-03-01

    Few studies have examined the co-morbidity between insomnia and sleep-disordered breathing in the clinical setting. This study evaluated treatment-seeking insomnia patients and their self-report of sleep breathing complaints. A retrospective chart review was conducted on 1,035 consecutive treatment-seeking, chronic insomnia patients who reported insomnia as their primary problem upon seeking care at a private, community-based sleep medical center. Measurements included the insomnia severity index, standard subjective sleep measures as well as rankings, attributions, and self-reports about sleep breathing disorders, problems, and symptoms. A total of 1,035 adult, treatment-seeking insomnia patients indicated insomnia interfered with daytime functioning, and their average insomnia severity was in the range of a clinically relevant problem: total sleep time (5.50 h, SD = 1.60), sleep efficiency (71.05 %, SD = 18.26), wake time after sleep onset (120.70 min, SD = 92.56), and an insomnia severity index (18.81, SD = 5.09). Of these 1,035 insomnia patients, 42 % also ranked a sleep breathing disorder among their list of reasons for seeking treatment, another 13 % revealed a concern about a sleep breathing problem, and another 26 % reported awareness of sleep breathing symptoms. Only 19 % of this clinical insomnia sample reported no awareness or concerns about sleep breathing disorders, problems, or symptoms. A greater proportion of men than women reported significantly more sleep breathing disorders, problems, or symptoms. Sleep breathing complaints were extremely common among a large sample of treatment-seeking, self-identified, adult chronic insomnia patients. Prospective prevalence research is needed to corroborate or revise these findings, and polysomnography should be considered in appropriate cohorts to determine the clinical relevance of treatment-seeking chronic insomnia patients' sleep breathing complaints.

  10. Breath detection by transcutaneous electromyography of the diaphragm and the Graseby capsule in preterm infants.

    PubMed

    de Waal, Cornelia G; Kraaijenga, Juliette V; Hutten, Gerard J; de Jongh, Frans H; van Kaam, Anton H

    2017-12-01

    To compare triggering, breath detection and delay time of the Graseby capsule (GC) and transcutaneous electromyography of the diaphragm (dEMG) in spontaneous breathing preterm infants. In this observational study, a 30 minutes respiration measurement was conducted by respiratory inductance plethysmography (RIP), the GC, and dEMG in stable preterm infants. Triggering was investigated with an in vitro set-up using the Infant Flow ® SiPAP TM system. The possibility to optimize breath detection was tested by developing new algorithms with the abdominal RIP band (RIP AB ) as gold standard. In a subset of breaths, the delay time was calculated between the inspiratory onset in the RIP AB signal and in the GC and dEMG signal. Fifteen preterm infants with a mean gestational age of 28 ± 2 weeks and a mean birth weight of 1086 ± 317 g were included. In total, 14 773 breaths were analyzed. Based on the GC and dEMG signal, the Infant Flow ® SiPAP™ system, respectively, triggered 67.8% and 62.6% of the breaths. Breath detection was improved to 99.9% for the GC and 113.4% for dEMG in new algorithms. In 1492 stable breaths, the median delay time of inspiratory onset detection was +154 ms (IQR +118 to +164) in the GC and -50 ms (IQR -90 to -22) in the dEMG signal. Breath detection using the GC can be improved by optimizing the algorithm. Transcutaneous dEMG provides similar breath detection but with the advantage of detecting the onset of inspiration earlier than the GC. © 2017 Wiley Periodicals, Inc.

  11. Exhaled human breath measurement method for assessing exposure to halogenated volatile organic compounds.

    PubMed

    Pleil, J D; Lindstrom, A B

    1997-05-01

    The organic constituents of exhaled human breath are representative of blood-borne concentrations through gas exchange in the blood/breath interface in the lungs. The presence of specific compounds can be an indicator of recent exposure or represent a biological response of the subject. For volatile organic compounds (VOCs), sampling and analysis of breath is preferred to direct measurement from blood samples because breath collection is noninvasive, potentially infectious waste is avoided, and the measurement of gas-phase analytes is much simpler in a gas matrix rather than in a complex biological tissue such as blood. To exploit these advantages, we have developed the "single breath canister" (SBC) technique, a simple direct collection method for individual alveolar breath samples, and adapted conventional gas chromatography-mass spectrometry analytical methods for trace-concentration VOC analysis. The focus of this paper is to describe briefly the techniques for making VOC measurements in breath, to present some specific applications for which these methods are relevant, and to demonstrate how to estimate exposure to example VOCs on the basis of breath elimination. We present data from three different exposure scenarios: (a) vinyl chloride and cis-1,2-dichloroethene from showering with contaminated water from a private well, (b) chloroform and bromodichloromethane from high-intensity swimming in chlorinated pool water, and (c) trichloroethene from a controlled exposure chamber experiment. In all cases, for all subjects, the experiment is the same: preexposure breath measurement, exposure to halogenated VOC, and a postexposure time-dependent series of breath measurements. Data are presented only to demonstrate the use of the method and how to interpret the analytical results.

  12. Relationship between Musical Characteristics and Temporal Breathing Pattern in Piano Performance

    PubMed Central

    Sakaguchi, Yutaka; Aiba, Eriko

    2016-01-01

    Although there is growing evidence that breathing is modulated by various motor and cognitive activities, the nature of breathing in musical performance has been little explored. The present study examined the temporal breath pattern in piano performance, aiming to elucidate how breath timing is related to musical organization/events and performance. In the experiments, the respiration of 15 professional and amateur pianists, playing 10 music excerpts in total (from four-octave C major scale, Hanon's exercise, J. S. Bach's Invention, Mozart's Sonatas, and Debussy's Clair de lune), was monitored by capnography. The relationship between breathing and musical characteristics was analyzed. Five major results were obtained. (1) Mean breath interval was shortened for excerpts in faster tempi. (2) Fluctuation of breath intervals was reduced for the pieces for finger exercise and those in faster tempi. Pianists showing large within-trial fluctuation also exhibited large inter-excerpt difference. (3) Inter-trial consistency of the breath patterns depended on the excerpts. Consistency was generally reduced for the excerpts that could be performed mechanically (i.e., pieces for finger exercise), but interestingly, one third of the participant showed consistent patterns for the simple scale, correlated with the ascending/descending sequences. (4) Pianists tended to exhale just after the music onsets, inhale at the rests, and inhibit inhale during the slur parts. There was correlation between breathing pattern and two-voice polyphonic structure for several participants. (5) Respiratory patterns were notably different among the pianists. Every pianist showed his or her own characteristic features commonly for various musical works. These findings suggest that breathing in piano performance depends not only on musical parameters and organization written in the score but also some pianist-dependent factors which might be ingrained to individual pianists. PMID:27516736

  13. Relationship between Musical Characteristics and Temporal Breathing Pattern in Piano Performance.

    PubMed

    Sakaguchi, Yutaka; Aiba, Eriko

    2016-01-01

    Although there is growing evidence that breathing is modulated by various motor and cognitive activities, the nature of breathing in musical performance has been little explored. The present study examined the temporal breath pattern in piano performance, aiming to elucidate how breath timing is related to musical organization/events and performance. In the experiments, the respiration of 15 professional and amateur pianists, playing 10 music excerpts in total (from four-octave C major scale, Hanon's exercise, J. S. Bach's Invention, Mozart's Sonatas, and Debussy's Clair de lune), was monitored by capnography. The relationship between breathing and musical characteristics was analyzed. Five major results were obtained. (1) Mean breath interval was shortened for excerpts in faster tempi. (2) Fluctuation of breath intervals was reduced for the pieces for finger exercise and those in faster tempi. Pianists showing large within-trial fluctuation also exhibited large inter-excerpt difference. (3) Inter-trial consistency of the breath patterns depended on the excerpts. Consistency was generally reduced for the excerpts that could be performed mechanically (i.e., pieces for finger exercise), but interestingly, one third of the participant showed consistent patterns for the simple scale, correlated with the ascending/descending sequences. (4) Pianists tended to exhale just after the music onsets, inhale at the rests, and inhibit inhale during the slur parts. There was correlation between breathing pattern and two-voice polyphonic structure for several participants. (5) Respiratory patterns were notably different among the pianists. Every pianist showed his or her own characteristic features commonly for various musical works. These findings suggest that breathing in piano performance depends not only on musical parameters and organization written in the score but also some pianist-dependent factors which might be ingrained to individual pianists.

  14. Mechanics of lung ventilation in a post-metamorphic salamander, Ambystoma Tigrinum.

    PubMed

    Simons, R S; Bennett, W O; Brainerd, E L

    2000-03-01

    The mechanics of lung ventilation in frogs and aquatic salamanders has been well characterized, whereas lung ventilation in terrestrial-phase (post-metamorphic) salamanders has received little attention. We used electromyography (EMG), X-ray videography, standard videography and buccal and body cavity pressure measurements to characterize the ventilation mechanics of adult (post-metamorphic) tiger salamanders (Ambystoma tigrinum). Three results emerged: (i) under terrestrial conditions or when floating at the surface of the water, adult A. tigrinum breathed through their nares using a two-stroke buccal pump; (ii) in addition to this narial two-stroke pump, adult tiger salamanders also gulped air in through their mouths using a modified two-stroke buccal pump when in an aquatic environment; and (iii) exhalation in adult tiger salamanders is active during aquatic gulping breaths, whereas exhalation appears to be passive during terrestrial breathing at rest. Active exhalation in aquatic breaths is indicated by an increase in body cavity pressure during exhalation and associated EMG activity in the lateral hypaxial musculature, particularly the M. transversus abdominis. In terrestrial breathing, no EMG activity in the lateral hypaxial muscles is generally present, and body cavity pressure decreases during exhalation. In aquatic breaths, tidal volume is larger than in terrestrial breaths, and breathing frequency is much lower (approximately 1 breath 10 min(-)(1 )versus 4-6 breaths min(-)(1)). The use of hypaxial muscles to power active exhalation in the aquatic environment may result from the need for more complete exhalation and larger tidal volumes when breathing infrequently. This hypothesis is supported by previous findings that terrestrial frogs ventilate their lungs with small tidal volumes and exhale passively, whereas aquatic frogs and salamanders use large tidal volumes and and exhale actively.

  15. SU-E-T-247: Determinations of the Optimal Phase for Respiratory Gated Radiotherapy From Statistical Analysis Using a Visible Guidance System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oh, S; Yea, J; Kang, M

    Purpose: Respiratory gated radiation therapy (RGRT) is used to minimize the radiation dose to normal tissue in lung cancer patients. Determination of the optimal point in the respiratory phase of a patient is important in RGRT but it is not easy. The goal of the present study was to see if a visible guidance system is helpful in determining the optimal phase in respiratory gated therapy. Methods: The breathing signals of 23 lung cancer patients were recorded with a Real-time Position Management (RPM) respiratory gating system (Varian, USA). The patients underwent breathing training with our visible guidance system, after whichmore » their breathing signals were recorded during 5 min of free breathing and 5 min of guided breathing. The breathing signals recorded between 3 and 5 min before and after training were compared. We performed statistical analysis of the breathing signals to find the optimal duty cycle in guided breathing for RGRT. Results: The breathing signals aided by the visible guidance system had more regular cycles over time and smaller variations in the positions of the marker block than the free breathing signals. Of the 23 lung cancer patients, 19 showed statistically significant differences by time when the values obtained before and after breathing were compared (p < 0.05); 30% and 40% of the duty cycle, respectively, was determined to be the most effective, and the corresponding phases were 30 60% (duty cycle, 30%; p < 0.05) and 30 70% (duty cycle, 40%; p < 0.05). Conclusion: Respiratory regularity was significantly improved with the use of the RPM with our visible guiding system; therefore, it would help improve the accuracy and efficiency of RGRT.« less

  16. Respiratory rate extraction from pulse oximeter and electrocardiographic recordings.

    PubMed

    Lee, Jinseok; Florian, John P; Chon, Ki H

    2011-11-01

    We present an algorithm of respiratory rate extraction using particle filter (PF), which is applicable to both photoplethysmogram (PPG) and electrocardiogram (ECG) signals. For the respiratory rate estimation, 1 min data are analyzed with combination of a PF method and an autoregressive model where among the resultant coefficients, the corresponding pole angle with the highest magnitude is searched since this reflects the closest approximation of the true breathing rate. The PPG data were collected from 15 subjects with the metronome breathing rate ranging from 24 to 36 breaths per minute in the supine and upright positions. The ECG data were collected from 11 subjects with spontaneous breathing ranging from 36 to 60 breaths per minute during treadmill exercises. Our method was able to accurately extract respiratory rates for both metronome and spontaneous breathing even during strenuous exercises. More importantly, despite slow increases in breathing rates concomitant with greater exercise vigor with time, our method was able to accurately track these progressive increases in respiratory rates. We quantified the accuracy of our method by using the mean, standard deviation and interquartile range of the error rates which all reflected high accuracy in estimating the true breathing rates. We are not aware of any other algorithms that are able to provide accurate respiratory rates directly from either ECG signals or PPG signals with spontaneous breathing during strenuous exercises. Our method is near real-time realizable because the computational time on 1 min data segment takes only 10 ms on a 2.66 GHz Intel Core2 microprocessor; the data are subsequently shifted every 10 s to obtain near-continuous breathing rates. This is an attractive feature since most other techniques require offline data analyses to estimate breathing rates.

  17. Volatile organic compounds as breath biomarkers for active and passive smoking.

    PubMed

    Gordon, Sydney M; Wallace, Lance A; Brinkman, Marielle C; Callahan, Patrick J; Kenny, Donald V

    2002-07-01

    We used real-time breath measurement technology to investigate the suitability of some volatile organic compounds (VOCs) as breath biomarkers for active and passive smoking and to measure actual exposures and resulting breath concentrations for persons exposed to tobacco smoke. Experiments were conducted with five smoker/nonsmoker pairs. The target VOCs included benzene, 1,3-butadiene, and the cigarette smoke biomarker 2,5-dimethylfuran. This study includes what we believe to be the first measurements of 1,3-butadiene in smokers' and nonsmokers' breath. The 1,3-butadiene and 2,5-dimethylfuran peak levels in the smokers' breath were similar (360 and 376 microg/m(3), respectively); the average benzene peak level was 522 microg/m(3). We found higher peak values of the target chemicals and shorter residence times in the body than previously reported, probably because of the improved time resolution made possible by the continuous breath measurement method. The real-time breath analyzer also showed the presence of the chemicals after exposure in the breath of the nonsmokers, but at greatly reduced levels. Single breath samples collected in evacuated canisters and analyzed independently with gas chromatography/mass spectrometry confirmed the presence of the target compounds in the postexposure breath of the nonsmokers but indicated that there was some contamination of the breath analyzer measurements. This was likely caused by desorption of organics from condensed tar in the analyzer tubing and on the quartz fiber filter used to remove particles. We used the decay data from the smokers to estimate residence times for the target chemicals. A two-compartment exponential model generally gave a better fit to the experimental decay data from the smokers than a single-compartment model. Residence times for benzene, 1,3-butadiene, and 2,5-dimethylfuran ranged from 0.5 (1,3-butadiene) to 0.9 min (benzene) for tau1 and were essentially constant (14 min) for tau2. These findings will be useful in models of environmental tobacco smoke exposure and risk.

  18. PERIODIC AIR-BREATHING BEHAVIOUR IN A PRIMITIVE FISH REVEALED BY SPECTRAL ANALYSIS

    PubMed

    Hedrick; Katz; Jones

    1994-12-01

    The ventilatory patterns of air-breathing fish are commonly described as 'arrhythmic' or 'irregular' because the variable periods of breath-holding are punctuated by seemingly unpredictable air-breathing events (see Shelton et al. 1986). This apparent arrhythmicity contrasts with the perceived periodism or regularity in the gill ventilation patterns of some fish and with lung ventilation in birds and mammals. In this sense, periodism refers to behaviour that occurs with a definite, recurring interval (Bendat and Piersol, 1986). The characterisation of aerial ventilation patterns in fish as 'aperiodic' has been generally accepted on the basis of qualitative examination and it remains to be validated with rigorous testing. The bowfin, Amia calva (L.), is a primitive air-breathing fish that makes intermittent excursions to the air­water interface to gulp air, which is transferred to its well-vascularized gas bladder. Its phylogenetic position as the only extant member of the sister lineage of modern teleosts affords a unique opportunity to examine the evolution of aerial ventilation and provides a model for the examination of ventilatory patterns in primitive fishes. To establish whether Amia calva exhibit a particular pattern of air-breathing, we examined time series records of aerial ventilations from undisturbed fish over long periods (8 h). These records were the same as those used to calculate average ventilation intervals under a variety of experimental conditions (Hedrick and Jones, 1993). Their study also reported the occurrence of two distinct breath types. Type I breaths were characterised by an exhalation followed by an inhalation, whereas type II breaths were characterised by inhalation only. It was also hypothesized that the type I breaths were employed to meet oxygen demands, whereas the type II breaths were used to regulate gas bladder volume. However, they did not investigate the potential presence of a periodic ventilatory pattern. We now report the results of just such an analysis of ventilatory pattern that demonstrates a clear periodism to air-breathing in a primitive fish.

  19. Deep-breathing exercises reduce atelectasis and improve pulmonary function after coronary artery bypass surgery.

    PubMed

    Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Friberg, Orjan; Hedenstierna, Göran; Tenling, Arne

    2005-11-01

    To investigate the effects of deep-breathing exercises on pulmonary function, atelectasis, and arterial blood gas levels after coronary artery bypass graft (CABG) surgery. In a prospective, randomized trial, patients performing deep-breathing exercises (n = 48) were compared to a control group (n = 42) who performed no breathing exercises postoperatively. Patient management was similar in the groups in terms of assessment, positioning, and mobility. The patients in the deep-breathing group were instructed to perform breathing exercises hourly during daytime for the first 4 postoperative days. The exercises consisted of 30 slow, deep breaths performed with a positive expiratory pressure blow-bottle device (+ 10 cm H(2)O). Spirometric measurements, spiral CT (three transverse levels), arterial blood gas analysis, and scoring of subjective experience of the breathing exercises were performed on the fourth postoperative day. Atelectasis was only half the size in the deep-breathing group compared to the control group, amounting to 2.6 +/- 2.2% vs 4.7 +/- 5.7% (p = 0.045) at the basal level and 0.1 +/- 0.2% vs 0.3 +/- 0.5% (mean +/- SD) [p = 0.01] at the apical level. Compared to the control subjects, the patients in the deep-breathing group had a significantly smaller reduction in FVC (to 71 +/- 12%, vs 64 +/- 13% of the preoperative values; p = 0.01) and FEV(1) (to 71 +/- 11%, vs 65 +/- 13% of the preoperative values; p = 0.01). Arterial oxygen tension, carbon dioxide tension, fever, or length of ICU or hospital stay did not differ between the groups. In the deep-breathing group, 72% of the patients experienced a subjective benefit from the exercises. Patients performing deep-breathing exercises after CABG surgery had significantly smaller atelectatic areas and better pulmonary function on the fourth postoperative day compared to a control group performing no exercises.

  20. Amplitude gating for a coached breathing approach in respiratory gated 10 MV flattening filter‐free VMAT delivery

    PubMed Central

    Lee, Richard; Gete, Ermias; Duzenli, Cheryl

    2015-01-01

    The purpose of this study was to investigate amplitude gating combined with a coached breathing strategy for 10 MV flattening filter‐free (FFF) volumetric‐modulated arc therapy (VMAT) on the Varian TrueBeam linac. Ten patient plans for VMAT SABR liver were created using the Eclipse treatment planning system (TPS). The verification plans were then transferred to a CT‐scanned Quasar phantom and delivered on a TrueBeam linac using a 10 MV FFF beam and Varian's real‐time position management (RPM) system for respiratory gating based on breathing amplitude. Breathing traces were acquired from ten patients using two kinds of breathing patterns: free breathing and an interrupted (~5 s pause) end of exhale coached breathing pattern. Ion chamber and Gafchromic film measurements were acquired for a gated delivery while the phantom moved under the described breathing patterns, as well as for a nongated stationary phantom delivery. The gate window was set to obtain a range of residual target motion from 2–5 mm. All gated deliveries on a moving phantom have been shown to be dosimetrically equivalent to the nongated deliveries on a static phantom, with differences in point dose measurements under 1% and average gamma 2%/2 mm agreement above 98.7%. Comparison with the treatment planning system also resulted in good agreement, with differences in point‐dose measurements under 2.5% and average gamma 3%/3 mm agreement of 97%. The use of a coached breathing pattern significantly increases the duty cycle, compared with free breathing, and allows for shorter treatment times. Patients' free‐breathing patterns contain considerable variability and, although dosimetric results for gated delivery may be acceptable, it is difficult to achieve efficient treatment delivery. A coached breathing pattern combined with a 5 mm amplitude gate, resulted in both high‐quality dose distributions and overall shortest gated beam delivery times. PACS number: 87.55.Qr PMID:26219000

  1. Bench experiments comparing simulated inspiratory effort when breathing helium-oxygen mixtures to that during positive pressure support with air.

    PubMed

    Martin, Andrew R; Katz, Ira M; Jenöfi, Katharina; Caillibotte, Georges; Brochard, Laurent; Texereau, Joëlle

    2012-10-03

    Inhalation of helium-oxygen (He/O2) mixtures has been explored as a means to lower the work of breathing of patients with obstructive lung disease. Non-invasive ventilation (NIV) with positive pressure support is also used for this purpose. The bench experiments presented herein were conducted in order to compare simulated patient inspiratory effort breathing He/O2 with that breathing medical air, with or without pressure support, across a range of adult, obstructive disease patterns. Patient breathing was simulated using a dual-chamber mechanical test lung, with the breathing compartment connected to an ICU ventilator operated in NIV mode with medical air or He/O2 (78/22 or 65/35%). Parabolic or linear resistances were inserted at the inlet to the breathing chamber. Breathing chamber compliance was also varied. The inspiratory effort was assessed for the different gas mixtures, for three breathing patterns, with zero pressure support (simulating unassisted spontaneous breathing), and with varying levels of pressure support. Inspiratory effort increased with increasing resistance and decreasing compliance. At a fixed resistance and compliance, inspiratory effort increased with increasing minute ventilation, and decreased with increasing pressure support. For parabolic resistors, inspiratory effort was lower for He/O2 mixtures than for air, whereas little difference was measured for nominally linear resistance. Relatively small differences in inspiratory effort were measured between the two He/O2 mixtures. Used in combination, reductions in inspiratory effort provided by He/O2 and pressure support were additive. The reduction in inspiratory effort afforded by breathing He/O2 is strongly dependent on the severity and type of airway obstruction. Varying helium concentration between 78% and 65% has small impact on inspiratory effort, while combining He/O2 with pressure support provides an additive reduction in inspiratory effort. In addition, breathing He/O2 alone may provide an alternative to pressure support in circumstances where NIV is not available or poorly tolerated.

  2. Motion management within two respiratory-gating windows: feasibility study of dual quasi-breath-hold technique in gated medical procedures

    NASA Astrophysics Data System (ADS)

    Kim, Taeho; Kim, Siyong; Park, Yang-Kyun; Youn, Kaylin K.; Keall, Paul; Lee, Rena

    2014-11-01

    A dual quasi-breath-hold (DQBH) technique is proposed for respiratory motion management (a hybrid technique combining breathing-guidance with breath-hold task in the middle). The aim of this study is to test a hypothesis that the DQBH biofeedback system improves both the capability of motion management and delivery efficiency. Fifteen healthy human subjects were recruited for two respiratory motion measurements (free breathing and DQBH biofeedback breathing for 15 min). In this study, the DQBH biofeedback system utilized the abdominal position obtained using an real-time position management (RPM) system (Varian Medical Systems, Palo Alto, USA) to audio-visually guide a human subject for 4 s breath-hold at EOI and 90% EOE (EOE90%) to improve delivery efficiency. We investigated the residual respiratory motion and the delivery efficiency (duty-cycle) of abdominal displacement within the gating window. The improvement of the abdominal motion reproducibility was evaluated in terms of cycle-to-cycle displacement variability, respiratory period and baseline drift. The DQBH biofeedback system improved the abdominal motion management capability compared to that with free breathing. With a phase based gating (mean ± std: 55  ±  5%), the averaged root mean square error (RMSE) of the abdominal displacement in the dual-gating windows decreased from 2.26 mm of free breathing to 1.16 mm of DQBH biofeedback (p-value = 0.007). The averaged RMSE of abdominal displacement over the entire respiratory cycles reduced from 2.23 mm of free breathing to 1.39 mm of DQBH biofeedback breathing in the dual-gating windows (p-value = 0.028). The averaged baseline drift dropped from 0.9 mm min-1 with free breathing to 0.09 mm min-1 with DQBH biofeedback (p-value = 0.048). The averaged duty-cycle with an 1 mm width of displacement bound increased from 15% of free breathing to 26% of DQBH biofeedback (p-value = 0.003). The study demonstrated that the DQBH biofeedback system has the potential to significantly reduce the residual respiratory motion with the improved duty cycle during the respiratory gating procedure.

  3. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management

    PubMed Central

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-01-01

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no “best-practice method” for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests. PMID:27483281

  4. A Portable Real-Time Ringdown Breath Acetone Analyzer: Toward Potential Diabetic Screening and Management.

    PubMed

    Jiang, Chenyu; Sun, Meixiu; Wang, Zhennan; Chen, Zhuying; Zhao, Xiaomeng; Yuan, Yuan; Li, Yingxin; Wang, Chuji

    2016-07-30

    Breath analysis has been considered a suitable tool to evaluate diseases of the respiratory system and those that involve metabolic changes, such as diabetes. Breath acetone has long been known as a biomarker for diabetes. However, the results from published data by far have been inconclusive regarding whether breath acetone is a reliable index of diabetic screening. Large variations exist among the results of different studies because there has been no "best-practice method" for breath-acetone measurements as a result of technical problems of sampling and analysis. In this mini-review, we update the current status of our development of a laser-based breath acetone analyzer toward real-time, one-line diabetic screening and a point-of-care instrument for diabetic management. An integrated standalone breath acetone analyzer based on the cavity ringdown spectroscopy technique has been developed. The instrument was validated by using the certificated gas chromatography-mass spectrometry. The linear fittings suggest that the obtained acetone concentrations via both methods are consistent. Breath samples from each individual subject under various conditions in total, 1257 breath samples were taken from 22 Type 1 diabetic (T1D) patients, 312 Type 2 diabetic (T2D) patients, which is one of the largest numbers of T2D subjects ever used in a single study, and 52 non-diabetic healthy subjects. Simultaneous blood glucose (BG) levels were also tested using a standard diabetic management BG meter. The mean breath acetone concentrations were determined to be 4.9 ± 16 ppm (22 T1D), and 1.5 ± 1.3 ppm (312 T2D), which are about 4.5 and 1.4 times of the one in the 42 non-diabetic healthy subjects, 1.1 ± 0.5 ppm, respectively. A preliminary quantitative correlation (R = 0.56, p < 0.05) between the mean individual breath acetone concentration and the mean individual BG levels does exist in 20 T1D subjects with no ketoacidosis. No direct correlation is observed in T1D subjects, T2D subjects, and healthy subjects. The results from a relatively large number of subjects tested indicate that an elevated mean breath acetone concentration exists in diabetic patients in general. Although many physiological parameters affect breath acetone, under a specifically controlled condition fast (<1 min) and portable breath acetone measurement can be used for screening abnormal metabolic status including diabetes, for point-of-care monitoring status of ketone bodies which have the signature smell of breath acetone, and for breath acetone related clinical studies requiring a large number of tests.

  5. Epiglottitis

    MedlinePlus

    ... used. This examination is best done in the operating room or a similar setting where sudden breathing problems ... (ICU). Treatment involves methods to help the person breathe, including: Breathing tube ( ...

  6. Chlorinated lime poisoning

    MedlinePlus

    ... AND AIRWAYS Breathing difficulty (from breathing in the chlorinated lime) Throat swelling (which may also cause breathing difficulty) SKIN Burns Holes (necrosis) in the skin or tissues underneath Irritation

  7. A Study on How to Breathe Properly When Practicing Tai Chi Chuan

    ERIC Educational Resources Information Center

    Yang, Hanchun

    2011-01-01

    When practicing Tai Chi Chuan, proper breath plays an important role in shaping Tai Chi Chuan's style and its fitness value. The paper aims to analyse the postures of Tai Chi Chuan and its breath characteristics. The paper also presents some new insights on how to co-ordinate breath with postures by case studies.

  8. Refinement of Speech Breathing in Healthy 4- to 6-Year-Old Children

    ERIC Educational Resources Information Center

    Boliek, Carol A.; Hixon, Thomas J.; Watson, Peter J.; Jones, Patricia B.

    2009-01-01

    Purpose: The purpose of this study was to offer a better understanding of the development of neuromotor control for speech breathing and provide a normative data set that can serve as a useful standard for clinical evaluation and management of young children with speech disorders involving the breathing subsystem. Method: Speech breathing was…

  9. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...

  10. Progress of air-breathing cathode in microbial fuel cells

    NASA Astrophysics Data System (ADS)

    Wang, Zejie; Mahadevan, Gurumurthy Dummi; Wu, Yicheng; Zhao, Feng

    2017-07-01

    Microbial fuel cell (MFC) is an emerging technology to produce green energy and vanquish the effects of environmental contaminants. Cathodic reactions are vital for high electrical power density generated from MFCs. Recently tremendous attentions were paid towards developing high performance air-breathing cathodes. A typical air-breathing cathode comprises of electrode substrate, catalyst layer, and air-diffusion layer. Prior researches demonstrated that each component influenced the performance of air-breathing cathode MFCs. This review summarized the progress in development of the individual component and elaborated main factors to the performance of air-breathing cathode.

  11. ABA-Cloud: support for collaborative breath research

    PubMed Central

    Elsayed, Ibrahim; Ludescher, Thomas; King, Julian; Ager, Clemens; Trosin, Michael; Senocak, Uygar; Brezany, Peter; Feilhauer, Thomas; Amann, Anton

    2016-01-01

    This paper introduces the advanced breath analysis (ABA) platform, an innovative scientific research platform for the entire breath research domain. Within the ABA project, we are investigating novel data management concepts and semantic web technologies to document breath analysis studies for the long run as well as to enable their full automatic reproducibility. We propose several concept taxonomies (a hierarchical order of terms from a glossary of terms), which can be seen as a first step toward the definition of conceptualized terms commonly used by the international community of breath researchers. They build the basis for the development of an ontology (a concept from computer science used for communication between machines and/or humans and representation and reuse of knowledge) dedicated to breath research. PMID:23619467

  12. ABA-Cloud: support for collaborative breath research.

    PubMed

    Elsayed, Ibrahim; Ludescher, Thomas; King, Julian; Ager, Clemens; Trosin, Michael; Senocak, Uygar; Brezany, Peter; Feilhauer, Thomas; Amann, Anton

    2013-06-01

    This paper introduces the advanced breath analysis (ABA) platform, an innovative scientific research platform for the entire breath research domain. Within the ABA project, we are investigating novel data management concepts and semantic web technologies to document breath analysis studies for the long run as well as to enable their full automatic reproducibility. We propose several concept taxonomies (a hierarchical order of terms from a glossary of terms), which can be seen as a first step toward the definition of conceptualized terms commonly used by the international community of breath researchers. They build the basis for the development of an ontology (a concept from computer science used for communication between machines and/or humans and representation and reuse of knowledge) dedicated to breath research.

  13. Effect of exhaled moisture on breathing resistance of N95 filtering facepiece respirators.

    PubMed

    Roberge, Raymond J; Bayer, Emily; Powell, Jeffrey B; Coca, Aitor; Roberge, Marc R; Benson, Stacey M

    2010-08-01

    This study evaluated the effect of exhaled moisture on the breathing resistance of three classes of filtering facepiece respirators (FFR) following 4 h of continuous wear at a breathing volume of 40 l min(-1), utilizing an automated breathing and metabolic simulator as a human surrogate. After 4 h, inhalation and exhalation resistance increased by 0.43 and 0.23 mm of H(2)O pressure, respectively, and average moisture retention in the respirators was 0.26 ml. Under ambient conditions similar to those of the current study, and at similar breathing volumes, it is unlikely that exhaled moisture will add significantly to the breathing resistance of filtering facepiece respirators (FFR) over 4 h of use.

  14. Epilepsy and the ketogenic diet: assessment of ketosis in children using breath acetone.

    PubMed

    Musa-Veloso, Kathy; Rarama, Exequiel; Comeau, Felix; Curtis, Rosalind; Cunnane, Stephen

    2002-09-01

    High-fat ketogenic diets increase ketones (acetoacetate, beta-hydroxybutyrate, and acetone) and are used to treat refractory seizures. Although ketosis is an integral aspect of these therapeutic regimens, the direct importance of ketosis to seizure control needs further investigation. An examination of this relationship requires a reliable, minimally invasive measure of ketosis that can be performed frequently. In the present study, we examined the use of breath acetone as a measure of ketosis in children with refractory seizures on a classic ketogenic diet. Results were compared with breath acetone levels in epilepsy and healthy controls. Children on the ketogenic diet had significantly higher fasting breath acetone compared with epilepsy or healthy controls (2530 +/- 600 nmol/L versus 19 +/- 9 nmol/L and 21 +/- 4 nmol/L, respectively; p < 0.05). One hour after consumption of a ketogenic breakfast meal, breath acetone increased significantly in epilepsy and healthy controls (p < 0.05), but not in children on a ketogenic diet. Children who were on the ketogenic diet for longer periods of time had a significantly lower fasting breath acetone (R(2) = 0.55, p = 0.014). In one child on the ketogenic diet, breath acetone was determined hourly over a 9-h period, both by gas chromatography and by a prototype hand-held breath acetone analyzer. Preliminary results using this hand-held breath acetone analyzer are encouraging. Breath acetone may be a useful tool in examining the relationship between ketosis and seizure control and enhancing our understanding of the mechanism of the ketogenic diet.

  15. Clinical significance of the glucose breath test in patients with inflammatory bowel disease.

    PubMed

    Lee, Ji Min; Lee, Kang-Moon; Chung, Yoon Yung; Lee, Yang Woon; Kim, Dae Bum; Sung, Hea Jung; Chung, Woo Chul; Paik, Chang-Nyol

    2015-06-01

    Small intestinal bacterial overgrowth which has recently been diagnosed with the glucose breath test is characterized by excessive colonic bacteria in the small bowel, and results in gastrointestinal symptoms that mimic symptoms of inflammatory bowel disease. This study aimed to estimate the positivity of the glucose breath test and investigate its clinical role in inflammatory bowel disease. Patients aged > 18 years with inflammatory bowel disease were enrolled. All patients completed symptom questionnaires. Fecal calprotectin level was measured to evaluate the disease activity. Thirty historical healthy controls were used to determine normal glucose breath test values. A total of 107 patients, 64 with ulcerative colitis and 43 with Crohn's disease, were included. Twenty-two patients (20.6%) were positive for the glucose breath test (30.2%, Crohn's disease; 14.1%, ulcerative colitis). Positive rate of the glucose breath test was significantly higher in patients with Crohn's disease than in healthy controls (30.2% vs 6.7%, P=0.014). Bloating, flatus, and satiety were higher in glucose breath test-positive patients than glucose breath test-negative patients (P=0.021, 0.014, and 0.049, respectively). The positivity was not correlated with the fecal calprotectin level. The positive rate of the glucose breath test was higher in patients with inflammatory bowel disease, especially Crohn's disease than in healthy controls; gastrointestinal symptoms of patients with inflammatory bowel disease were correlated with this positivity. Glucose breath test can be used to manage intestinal symptoms of patients with inflammatory bowel disease. © 2015 Journal of Gastroenterology and Hepatology Foundation and Wiley Publishing Asia Pty Ltd.

  16. Slow Breathing and Hypoxic Challenge: Cardiorespiratory Consequences and Their Central Neural Substrates

    PubMed Central

    Critchley, Hugo D.; Nicotra, Alessia; Chiesa, Patrizia A.; Nagai, Yoko; Gray, Marcus A.; Minati, Ludovico; Bernardi, Luciano

    2015-01-01

    Controlled slow breathing (at 6/min, a rate frequently adopted during yoga practice) can benefit cardiovascular function, including responses to hypoxia. We tested the neural substrates of cardiorespiratory control in humans during volitional controlled breathing and hypoxic challenge using functional magnetic resonance imaging (fMRI). Twenty healthy volunteers were scanned during paced (slow and normal rate) breathing and during spontaneous breathing of normoxic and hypoxic (13% inspired O2) air. Cardiovascular and respiratory measures were acquired concurrently, including beat-to-beat blood pressure from a subset of participants (N = 7). Slow breathing was associated with increased tidal ventilatory volume. Induced hypoxia raised heart rate and suppressed heart rate variability. Within the brain, slow breathing activated dorsal pons, periaqueductal grey matter, cerebellum, hypothalamus, thalamus and lateral and anterior insular cortices. Blocks of hypoxia activated mid pons, bilateral amygdalae, anterior insular and occipitotemporal cortices. Interaction between slow breathing and hypoxia was expressed in ventral striatal and frontal polar activity. Across conditions, within brainstem, dorsal medullary and pontine activity correlated with tidal volume and inversely with heart rate. Activity in rostroventral medulla correlated with beat-to-beat blood pressure and heart rate variability. Widespread insula and striatal activity tracked decreases in heart rate, while subregions of insular cortex correlated with momentary increases in tidal volume. Our findings define slow breathing effects on central and cardiovascular responses to hypoxic challenge. They highlight the recruitment of discrete brainstem nuclei to cardiorespiratory control, and the engagement of corticostriatal circuitry in support of physiological responses that accompany breathing regulation during hypoxic challenge. PMID:25973923

  17. Breath-hold duration in man and the diving response induced by face immersion.

    PubMed

    Sterba, J A; Lundgren, C E

    1988-09-01

    The objective of this study in 5 selected volunteer subjects was to see whether the circulatory diving response which is elicited by breath holding and by cold water on the face would affect the duration of maximal-effort breath holds. Compared to control measurements (breath holding during resting, breathing with 35 degrees C water on the face) breath holding with the face cooled by 20 degrees C water caused a 12% reduction of heart rate, 6% reduction of cardiac output, 33% reduction in [corrected] forearm blood flow, and 9% rise in mean arterial blood pressure, but there was no difference in breath-hold duration (control and experimental both 94 s). There were also no differences in time of appearance of the first involuntary respiratory efforts during breath holding, in alveolar gas exchange, or in breaking-point alveolar O2 and CO2 tensions. When the diving response was magnified by a brief bout of exercise so that there was a 19% [corrected] reduction in heart rate, 23% reduction in cardiac output, and 48% reduction in forearm blood flow, breath-hold duration was still unaffected by face cooling. Compared to intermittent immersions, continuous exposure of the face to cold water abolished the diving response, probably by a cold adaptation of facial thermal receptors. These results with cooling of the face only are consistent with our earlier finding that there was a negative correlation between the duration of a maximal-effort breath hold and the diving response during whole-body submersion in cold water.

  18. Assessment of regional ventilation and deformation using 4D-CT imaging for healthy human lungs during tidal breathing

    PubMed Central

    Jahani, Nariman; Choi, Jiwoong; Iyer, Krishna; Hoffman, Eric A.

    2015-01-01

    This study aims to assess regional ventilation, nonlinearity, and hysteresis of human lungs during dynamic breathing via image registration of four-dimensional computed tomography (4D-CT) scans. Six healthy adult humans were studied by spiral multidetector-row CT during controlled tidal breathing as well as during total lung capacity and functional residual capacity breath holds. Static images were utilized to contrast static vs. dynamic (deep vs. tidal) breathing. A rolling-seal piston system was employed to maintain consistent tidal breathing during 4D-CT spiral image acquisition, providing required between-breath consistency for physiologically meaningful reconstructed respiratory motion. Registration-derived variables including local air volume and anisotropic deformation index (ADI, an indicator of preferential deformation in response to local force) were employed to assess regional ventilation and lung deformation. Lobar distributions of air volume change during tidal breathing were correlated with those of deep breathing (R2 ≈ 0.84). Small discrepancies between tidal and deep breathing were shown to be likely due to different distributions of air volume change in the left and the right lungs. We also demonstrated an asymmetric characteristic of flow rate between inhalation and exhalation. With ADI, we were able to quantify nonlinearity and hysteresis of lung deformation that can only be captured in dynamic images. Nonlinearity quantified by ADI is greater during inhalation, and it is stronger in the lower lobes (P < 0.05). Lung hysteresis estimated by the difference of ADI between inhalation and exhalation is more significant in the right lungs than that in the left lungs. PMID:26316512

  19. Changes in the highest frequency of breath sounds without wheezing during methacholine inhalation challenge in children.

    PubMed

    Habukawa, Chizu; Murakami, Katsumi; Mochizuki, Hiroyuki; Takami, Satoru; Muramatsu, Reiko; Tadaki, Hiromi; Hagiwara, Satomi; Mizuno, Takahisa; Arakawa, Hirokazu; Nagasaka, Yukio

    2010-04-01

    It is difficult for clinicians to identify changes in breath sounds caused by bronchoconstriction when wheezing is not audible. A breath sound analyser can identify changes in the frequency of breath sounds caused by bronchoconstriction. The present study aimed to identify the changes in the frequency of breath sounds during bronchoconstriction and bronchodilatation using a breath sound analyser. Thirty-six children (8.2 +/- 3.7 years; males : females, 22 : 14) underwent spirometry, methacholine inhalation challenge and breath sound analysis. Methacholine inhalation challenge was performed and baseline respiratory resistance, minimum dose of methacholine (bronchial sensitivity) and speed of bronchoconstriction in response to methacholine (Sm: bronchial reactivity) were calculated. The highest frequency of inspiratory breath sounds (HFI), the highest frequency of expiratory breath sounds (HFE) and the percentage change in HFI and HFE were determined. The HFI and HFE were compared before methacholine inhalation (pre-HFI and pre-HFE), when respiratory resistance reached double the baseline value (max HFI and max HFE), and after bronchodilator inhalation (post-HFI and post-HFE). Breath sounds increased during methacholine-induced bronchoconstriction. Max HFI was significantly greater than pre-HFI (P < 0.001), and decreased to the basal level after bronchodilator inhalation. Post-HFI was significantly lower than max HFI (P < 0.001). HFI and HFE were also significantly changed (P < 0.001). The percentage change in HFI showed a significant correlation with the speed of bronchoconstriction in response to methacholine (P = 0.007). Methacholine-induced bronchoconstriction significantly increased HFI, and the increase in HFI was correlated with bronchial reactivity.

  20. The Effect of Diaphragmatic Breathing on Attention, Negative Affect and Stress in Healthy Adults.

    PubMed

    Ma, Xiao; Yue, Zi-Qi; Gong, Zhu-Qing; Zhang, Hong; Duan, Nai-Yue; Shi, Yu-Tong; Wei, Gao-Xia; Li, You-Fa

    2017-01-01

    A growing number of empirical studies have revealed that diaphragmatic breathing may trigger body relaxation responses and benefit both physical and mental health. However, the specific benefits of diaphragmatic breathing on mental health remain largely unknown. The present study aimed to investigate the effect of diaphragmatic breathing on cognition, affect, and cortisol responses to stress. Forty participants were randomly assigned to either a breathing intervention group (BIG) or a control group (CG). The BIG received intensive training for 20 sessions, implemented over 8 weeks, employing a real-time feedback device, and an average respiratory rate of 4 breaths/min, while the CG did not receive this treatment. All participants completed pre- and post-tests of sustained attention and affect. Additionally, pre-test and post-test salivary cortisol concentrations were determined in both groups. The findings suggested that the BIG showed a significant decrease in negative affect after intervention, compared to baseline. In the diaphragmatic breathing condition, there was a significant interaction effect of group by time on sustained attention, whereby the BIG showed significantly increased sustained attention after training, compared to baseline. There was a significant interaction effect of group and time in the diaphragmatic breathing condition on cortisol levels, whereby the BIG had a significantly lower cortisol level after training, while the CG showed no significant change in cortisol levels. In conclusion, diaphragmatic breathing could improve sustained attention, affect, and cortisol levels. This study provided evidence demonstrating the effect of diaphragmatic breathing, a mind-body practice, on mental function, from a health psychology approach, which has important implications for health promotion in healthy individuals.

  1. The relationship of normal body temperature, end-expired breath temperature, and BAC/BrAC ratio in 98 physically fit human test subjects.

    PubMed

    Cowan, J Mack; Burris, James M; Hughes, James R; Cunningham, Margaret P

    2010-06-01

    The relationship between normal body temperature, end-expired breath temperature, and blood alcohol concentration (BAC)/breath alcohol concentration (BrAC) ratio was studied in 98 subjects (84 men, 14 women). Subjects consumed alcohol sufficient to produce a BrAC of at least 0.06 g/210 L 45-75 min after drinking. Breath samples were analyzed using an Intoxilyzer 8000 specially equipped to measure breath temperature. Venous blood samples and body temperatures were then taken. The mean body temperature of the men (36.6 degrees C) was lower than the women (37.0 degrees C); however, their mean breath temperatures were virtually identical (men: 34.5 degrees C; women: 34.6 degrees C). The BAC exceeded the BrAC for every subject. BAC/BrAC ratios were calculated from the BAC and BrAC analytical results. There was no difference in the BAC/BrAC ratios for men (1:2379) and women (1:2385). The correlation between BAC and BrAC was high (r = 0.938, p < 0.0001), whereas the correlations between body temperature and end-expired breath temperature, body temperature and BAC/BrAC ratio, and breath temperature and BAC/BrAC ratio were much lower. Neither normal body temperature nor end-expired breath temperature was strongly associated with BAC/BrAC ratio.

  2. A Portable Wireless Communication Platform Based on a Multi-Material Fiber Sensor for Real-Time Breath Detection

    PubMed Central

    Bellemare-Rousseau, Simon; Khalil, Mazen; Messaddeq, Younes

    2018-01-01

    In this paper, we present a new mobile wireless communication platform for real-time monitoring of an individual’s breathing rate. The platform takes the form of a wearable stretching T-shirt featuring a sensor and a detection base station. The sensor is formed by a spiral-shaped antenna made from a multi-material fiber connected to a compact transmitter. Based on the resonance frequency of the antenna at approximately 2.4 GHz, the breathing sensor relies on its Bluetooth transmitter. The contactless and non-invasive sensor is designed without compromising the user’s comfort. The sensing mechanism of the system is based on the detection of the signal amplitude transmitted wirelessly by the sensor, which is found to be sensitive to strain. We demonstrate the capability of the platform to detect the breathing rates of four male volunteers who are not in movement. The breathing pattern is obtained through the received signal strength indicator (RSSI) which is filtered and analyzed with home-made algorithms in the portable system. Numerical simulations of human breath are performed to support the experimental detection, and both results are in a good agreement. Slow, fast, regular, irregular, and shallow breathing types are successfully recorded within a frequency interval of 0.16–1.2 Hz, leading to a breathing rate varying from 10 to 72 breaths per minute. PMID:29587396

  3. Four-dimensional computed tomography based respiratory-gated radiotherapy with respiratory guidance system: analysis of respiratory signals and dosimetric comparison.

    PubMed

    Lee, Jung Ae; Kim, Chul Yong; Yang, Dae Sik; Yoon, Won Sup; Park, Young Je; Lee, Suk; Kim, Young Bum

    2014-01-01

    To investigate the effectiveness of respiratory guidance system in 4-dimensional computed tomography (4 DCT) based respiratory-gated radiation therapy (RGRT) by comparing respiratory signals and dosimetric analysis of treatment plans. The respiratory amplitude and period of the free, the audio device-guided, and the complex system-guided breathing were evaluated in eleven patients with lung or liver cancers. The dosimetric parameters were assessed by comparing free breathing CT plan and 4 DCT-based 30-70% maximal intensity projection (MIP) plan. The use of complex system-guided breathing showed significantly less variation in respiratory amplitude and period compared to the free or audio-guided breathing regarding the root mean square errors (RMSE) of full inspiration (P = 0.031), full expiration (P = 0.007), and period (P = 0.007). The dosimetric parameters including V(5 Gy), V(10 Gy), V(20 Gy), V(30 Gy), V(40 Gy), and V(50 Gy) of normal liver or lung in 4 DCT MIP plan were superior over free breathing CT plan. The reproducibility and regularity of respiratory amplitude and period were significantly improved with the complex system-guided breathing compared to the free or the audio-guided breathing. In addition, the treatment plan based on the 4D CT-based MIP images acquired with the complex system guided breathing showed better normal tissue sparing than that on the free breathing CT.

  4. When Breathing Interferes with Cognition: Experimental Inspiratory Loading Alters Timed Up-and-Go Test in Normal Humans.

    PubMed

    Nierat, Marie-Cécile; Demiri, Suela; Dupuis-Lozeron, Elise; Allali, Gilles; Morélot-Panzini, Capucine; Similowski, Thomas; Adler, Dan

    2016-01-01

    Human breathing stems from automatic brainstem neural processes. It can also be operated by cortico-subcortical networks, especially when breathing becomes uncomfortable because of external or internal inspiratory loads. How the "irruption of breathing into consciousness" interacts with cognition remains unclear, but a case report in a patient with defective automatic breathing (Ondine's curse syndrome) has shown that there was a cognitive cost of breathing when the respiratory cortical networks were engaged. In a pilot study of putative breathing-cognition interactions, the present study relied on a randomized design to test the hypothesis that experimentally loaded breathing in 28 young healthy subjects would have a negative impact on cognition as tested by "timed up-and-go" test (TUG) and its imagery version (iTUG). Progressive inspiratory threshold loading resulted in slower TUG and iTUG performance. Participants consistently imagined themselves faster than they actually were. However, progressive inspiratory loading slowed iTUG more than TUG, a finding that is unexpected with regard to the known effects of dual tasking on TUG and iTUG (slower TUG but stable iTUG). Insofar as the cortical networks engaged in response to inspiratory loading are also activated during complex locomotor tasks requiring cognitive inputs, we infer that competition for cortical resources may account for the breathing-cognition interference that is evidenced here.

  5. Additional Value of CH4 Measurement in a Combined 13C/H2 Lactose Malabsorption Breath Test: A Retrospective Analysis

    PubMed Central

    Houben, Els; De Preter, Vicky; Billen, Jaak; Van Ranst, Marc; Verbeke, Kristin

    2015-01-01

    The lactose hydrogen breath test is a commonly used, non-invasive method for the detection of lactose malabsorption and is based on an abnormal increase in breath hydrogen (H2) excretion after an oral dose of lactose. We use a combined 13C/H2 lactose breath test that measures breath 13CO2 as a measure of lactose digestion in addition to H2 and that has a better sensitivity and specificity than the standard test. The present retrospective study evaluated the results of 1051 13C/H2 lactose breath tests to assess the impact on the diagnostic accuracy of measuring breath CH4 in addition to H2 and 13CO2. Based on the 13C/H2 breath test, 314 patients were diagnosed with lactase deficiency, 138 with lactose malabsorption or small bowel bacterial overgrowth (SIBO), and 599 with normal lactose digestion. Additional measurement of CH4 further improved the accuracy of the test as 16% subjects with normal lactose digestion and no H2-excretion were found to excrete CH4. These subjects should have been classified as subjects with lactose malabsorption or SIBO. In conclusion, measuring CH4-concentrations has an added value to the 13C/H2 breath test to identify methanogenic subjects with lactose malabsorption or SIBO. PMID:26371034

  6. Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function.

    PubMed

    Vuissoz, Pierre-André; Odille, Freddy; Fernandez, Brice; Lohezic, Maelene; Benhadid, Adnane; Mandry, Damien; Felblinger, Jacques

    2012-02-01

    To assess cardiac function by means of a novel free-breathing cardiac magnetic resonance imaging (MRI) strategy. A stack of ungated 2D steady-state free precession (SSFP) slices was acquired during free breathing and reconstructed as cardiac cine imaging based on the generalized reconstruction by inversion of coupled systems (GRICS). A motion-compensated sliding window approach allows reconstructing cine movies with most motion artifacts cancelled. The proposed reconstruction uses prior knowledge from respiratory belts and electrocardiogram recordings and features a piecewise linear model that relates the electrocardiogram signal to cardiac displacements. The free-breathing protocol was validated in six subjects against a standard breath-held protocol. Image sharpness, as assessed by the image gradient entropy, was comparable to that of breath-held images and significantly better than in uncorrected images. Volumetric parameters of cardiac function in the left ventricle (LV) and right ventricle (RV) were similar, including end-systolic volumes, end-diastolic volumes and mass, stroke volumes, and ejection fractions (with differences of 3% ± 2.4 in the LV and 2.9% ± 4.4 in the RV). The duration of the free-breathing protocol was nearly the same as the breath-held protocol. Free-breathing cine-GRICS enables accurate assessment of volumetric parameters of cardiac function with efficient correction of motion. Copyright © 2011 Wiley Periodicals, Inc.

  7. Cross-cultural comparison of the sleep-disordered breathing prevalence among Americans and Japanese

    PubMed Central

    Yamagishi, Kazumasa; Ohira, Tetsuya; Nakano, Hiroshi; Bielinski, Suzette J.; Sakurai, Susumu; Imano, Hironori; Kiyama, Masahiko; Kitamura, Akihiko; Sato, Shinichi; Konishi, Masamitsu; Shahar, Eyal; Folsom, Aaron R.; Iso, Hiroyasu; Tanigawa, Takeshi

    2010-01-01

    To compare the sleep-disordered breathing prevalence among Hispanic and white Americans and Japanese, we performed a one-night sleep study with a single channel airflow monitor on 211 Hispanics and 246 whites from the Minnesota Field Center of the Multi-Ethnic Study of Atherosclerosis (MESA), and 978 Japanese from three community-based cohorts of the Circulatory Risk in Communities Study (CIRCS) in Japan. The respiratory disturbance index and sleep-disordered breathing, defined as respiratory disturbance index ≥ 15 disturbances/hr, were estimated. The sleep-disordered breathing prevalence was higher in men (34.2%) than women (14.8%), and higher among Hispanics (36.5%) and whites (33.3%) than among Japanese (18.4%), corresponding to differences in body mass index. Within body mass index strata, the race difference in sleep-disordered breathing was attenuated. This was also true when we adjusted for body mass index instead of stratification. The strong association between body mass index and sleep-disordered breathing was similar in Japanese and Americans. The sleep-disordered breathing prevalence was lower among Japanese than the Americans. However, the association of body mass index with sleep-disordered breathing was strong, and similar among the race/ethnic groups studied. The majority of the race/ethnic difference in sleep-disordered breathing prevalence was explained by a difference in body mass index distribution. PMID:20110399

  8. Partial liquid ventilation: effects of closed breathing systems, heat-and-moisture-exchangers and sodalime absorbers on perfluorocarbon evaporation.

    PubMed

    Wilms, C T; Schober, P; Kalb, R; Loer, S A

    2006-01-01

    During partial liquid ventilation perfluorocarbons are instilled into the airways from where they subsequently evaporate via the bronchial system. This process is influenced by multiple factors, such as the vapour pressure of the perfluorocarbons, the instilled volume, intrapulmonary perfluorocarbon distribution, postural positioning and ventilatory settings. In our study we compared the effects of open and closed breathing systems, a heat-and-moisture-exchanger and a sodalime absorber on perfluorocarbon evaporation during partial liquid ventilation. Isolated rat lungs were suspended from a force transducer. After intratracheal perfluorocarbon instillation (10 mL kg(-1)) the lungs were either ventilated with an open breathing system (n = 6), a closed breathing system (n = 6), an open breathing system with an integrated heat-and-moisture-exchanger (n = 6), an open breathing system with an integrated sodalime absorber (n = 6), or a closed breathing system with an integrated heat-and-moisture-exchanger and a sodalime absorber (n = 6). Evaporative perfluorocarbon elimination was determined gravimetrically. When compared to the elimination half-life in an open breathing system (1.2 +/- 0.07 h), elimination half-life was longer with a closed system (6.4 +/- 0.9 h, P 0.05) when compared to a closed system. Evaporative perfluorocarbon loss can be reduced effectively with closed breathing systems, followed by the use of sodalime absorbers and heat-and-moisture-exchangers.

  9. Acute Effects of Cannabis on Breath-Holding Duration

    PubMed Central

    Farris, Samantha G.; Metrik, Jane

    2016-01-01

    Distress intolerance (an individual’s perceived or actual inability to tolerate distressing psychological or physiological states) is associated with cannabis use. It is unknown whether a bio-behavioral index of distress intolerance, breath-holding duration, is acutely influenced (increased or decreased) by cannabis. Such information may further inform understanding of the expression of psychological or physiological distress post-cannabis use. This within-subjects study examined whether smoked marijuana with 2.7–3.0 % delta-9-tetrahydrocannabinol (THC), relative to placebo, acutely changed duration of breath-holding. Participants (n = 88; 65.9% male) were non-treatment seeking frequent cannabis users who smoked placebo or active THC cigarette on two separate study days and completed breath-holding task. Controlling for baseline breath-holding duration and participant sex, THC produced significantly lower breath-holding durations relative to placebo. There was a significant interaction of drug administration x frequency of cannabis use, such that THC decreased breath-holding time among less frequent but not among more frequent users. Findings indicate that cannabis may be exacerbating distress intolerance (via breath-holding duration). As compared to less frequent cannabis users, frequent users display tolerance to cannabis’ acute effects including increased ability to tolerate respiratory distress when holding breath. Objective measures of distress intolerance are sensitive to contextual factors such as acute drug intoxication, and may inform the link between cannabis use and the expression of psychological distress. PMID:27454678

  10. A Portable Wireless Communication Platform Based on a Multi-Material Fiber Sensor for Real-Time Breath Detection.

    PubMed

    Roudjane, Mourad; Bellemare-Rousseau, Simon; Khalil, Mazen; Gorgutsa, Stepan; Miled, Amine; Messaddeq, Younes

    2018-03-25

    In this paper, we present a new mobile wireless communication platform for real-time monitoring of an individual's breathing rate. The platform takes the form of a wearable stretching T-shirt featuring a sensor and a detection base station. The sensor is formed by a spiral-shaped antenna made from a multi-material fiber connected to a compact transmitter. Based on the resonance frequency of the antenna at approximately 2.4 GHz, the breathing sensor relies on its Bluetooth transmitter. The contactless and non-invasive sensor is designed without compromising the user's comfort. The sensing mechanism of the system is based on the detection of the signal amplitude transmitted wirelessly by the sensor, which is found to be sensitive to strain. We demonstrate the capability of the platform to detect the breathing rates of four male volunteers who are not in movement. The breathing pattern is obtained through the received signal strength indicator (RSSI) which is filtered and analyzed with home-made algorithms in the portable system. Numerical simulations of human breath are performed to support the experimental detection, and both results are in a good agreement. Slow, fast, regular, irregular, and shallow breathing types are successfully recorded within a frequency interval of 0.16-1.2 Hz, leading to a breathing rate varying from 10 to 72 breaths per minute.

  11. Air breathing in Magadi tilapia Alcolapia grahami, under normoxic and hyperoxic conditions, and the association with sunlight and reactive oxygen species.

    PubMed

    Johannsson, O E; Bergman, H L; Wood, C M; Laurent, P; Kavembe, D G; Bianchini, A; Maina, J N; Chevalier, C; Bianchini, L F; Papah, M B; Ojoo, R O

    2014-03-01

    Observations of the Magadi tilapia Alcolapia grahami in hot, highly alkaline Lake Magadi revealed that they air breathe not only during hypoxia, as described previously, but also during normoxia and hyperoxia. Air breathing under these latter conditions occurred within distinct groupings of fish (pods) and involved only a small proportion of the population. Air breathing properties (duration and frequency) were quantified from video footage. Air breathing within the population followed a diel pattern with the maximum extent of pod formation occurring in early afternoon. High levels of reactive oxygen species (ROS) in the water may be an irritant that encourages the air-breathing behaviour. The diel pattern of air breathing in the field and in experiments followed the diel pattern of ROS concentrations in the water which are amongst the highest reported in the literature (maximum daytime values of 2.53 – 8.10 μM H₂O₂). Interlamellar cell masses (ILCM) occurred between the gill lamellae of fish from the lagoon with highest ROS and highest oxygen levels, while fish from a normoxic lagoon with one third the ROS had little or no ILCM. This is the first record of air breathing in a facultative air-breathing fish in hyperoxic conditions and the first record of an ILCM in a cichlid species. © 2013 The Fisheries Society of the British Isles.

  12. Effect of Time-of-Flight Information on PET/MR Reconstruction Artifacts: Comparison of Free-breathing versus Breath-hold MR-based Attenuation Correction.

    PubMed

    Delso, Gaspar; Khalighi, Mohammed; Ter Voert, Edwin; Barbosa, Felipe; Sekine, Tetsuro; Hüllner, Martin; Veit-Haibach, Patrick

    2017-01-01

    Purpose To evaluate the magnitude and anatomic extent of the artifacts introduced on positron emission tomographic (PET)/magnetic resonance (MR) images by respiratory state mismatch in the attenuation map. Materials and Methods The method was tested on 14 patients referred for an oncologic examination who underwent PET/MR imaging. The acquisition included standard PET and MR series for each patient, and an additional attenuation correction series was acquired by using breath hold. PET data were reconstructed with and without time-of-flight (TOF) information, first by using the standard free-breathing attenuation map and then again by using the additional breath-hold map. Two-tailed paired t testing and linear regression with 0 intercept was performed on TOF versus non-TOF and free-breathing versus breath-hold data for all detected lesions. Results Fluorodeoxyglucose-avid lesions were found in eight of the 14 patients included in the study. The uptake differences (maximum standardized uptake values) between PET reconstructions with free-breathing versus breath-hold attenuation ranged, for non-TOF reconstructions, from -18% to 26%. The corresponding TOF reconstructions yielded differences from -15% to 18%. Conclusion TOF information was shown to reduce the artifacts caused at PET/MR by respiratory mismatch between emission and attenuation data. © RSNA, 2016 Online supplemental material is available for this article.

  13. Impact of Breathing 100% Oxygen on Radiation-Induced Cognitive Impairment

    PubMed Central

    Wheeler, Kenneth T.; Payne, Valerie; D’Agostino, Ralph B.; Walb, Matthew C.; Munley, Michael T.; Metheny-Barlow, Linda J.; Robbins, Mike E.

    2015-01-01

    Future space missions are expected to include increased extravehicular activities (EVAs) during which astronauts are exposed to high-energy space radiation while breathing 100% oxygen. Given that brain irradiation can lead to cognitive impairment, and that oxygen is a potent radiosensitizer, there is a concern that astronauts may be at greater risk of developing cognitive impairment when exposed to space radiation while breathing 100% O2 during an EVA. To address this concern, unanesthetized, unrestrained, young adult male Fischer 344 × Brown Norway rats were allowed to breathe 100% O2 for 30 min prior to, during and 2 h after whole-body irradiation with 0, 1, 3, 5 or 7 Gy doses of 18 MV X rays delivered from a medical linear accelerator at a dose rate of ~425 mGy/min. Irradiated and unirradiated rats breathing air (~21% O2) served as controls. Cognitive function was assessed 9 months postirradiation using the perirhinal cortex-dependent novel object recognition task. Cognitive function was not impaired until the rats breathing either air or 100% O2 received a whole-body dose of 7 Gy. However, at all doses, cognitive function of the irradiated rats breathing 100% O2 was improved over that of the irradiated rats breathing air. These data suggest that astronauts are not at greater risk of developing cognitive impairment when exposed to space radiation while breathing 100% O2 during an EVA. PMID:25338095

  14. Atelectasis

    MedlinePlus

    ... Prolonged bed rest with few changes in position Shallow breathing (may be caused by painful breathing) Tumors ... chest to loosen mucus plugs in the airway. Deep breathing exercises (with the help of incentive spirometry ...

  15. Can handling E85 motor fuel cause positive breath alcohol test results?

    PubMed

    Ran, Ran; Mullins, Michael E

    2013-09-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02-0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI.

  16. Variability in the blood/breath alcohol ratio and implications for evidentiary purposes.

    PubMed

    Jaffe, Dena H; Siman-Tov, Maya; Gopher, Asher; Peleg, Kobi

    2013-09-01

    The breath analyzer is an indispensable tool for identifying alcohol levels among drivers. While numerous studies have shown high correlations between blood and breath alcohol concentrations, most are limited by the study design. This study seeks to assess this relationship by minimizing potential measurement bias, document time from alcohol consumption to testing, and adjusting for potential confounders. A blinded study was performed using conditions closely resembling those in the field. The Draeger 7110 MKIII IL breath analyzer was used to assess breath alcohol concentrations (BrAC). Participants were 61 healthy volunteers aged 21-37 years with body mass index ≤30 and no history of alcoholism. A total of 242 valid blood/breath tests were performed in four test sets. The study results showed a high correlation coefficient between BrAC and blood alcohol concentration (BAC) levels (r = 0.983) with high sensitivity (97%) and specificity (93%). This strong association between the breath analyzer and BAC persisted even after adjustment for various stages of alcohol absorption. These results illustrate the high diagnostic sensitivity of the breath analyzer in field-tested conditions. © 2013 American Academy of Forensic Sciences.

  17. Fine-scale analysis of synchronous breathing in wild Indo-Pacific bottlenose dolphins (Tursiops aduncus).

    PubMed

    Sakai, Mai; Morisaka, Tadamichi; Kogi, Kazunobu; Hishii, Toru; Kohshima, Shiro

    2010-01-01

    We quantitatively analysed synchronous breathing for dyads in Indo-Pacific bottlenose dolphins at Mikura Island, Tokyo, Japan. For most cases, we observed dyads swimming in the same direction (97%), in close proximity (i.e., less than 1.5m) and with their body axes parallel as they breathed synchronously. Moreover, the pairs engaged in identical behaviour before and after the synchronous breathing episodes. These results suggest that the dolphins synchronize their movements, and that synchronous breathing is a component of "pair-swimming", an affiliative social behaviour. Same sex pairs of the same age class frequently engaged in synchronous breathing for adults and subadults, as well as mother-calf and escort-calf pairs. The distance between individuals during synchronous breathing for mother-calf pairs was less than for other pairs. The distance observed between individuals for female pairs was less than for male pairs. The time differences between each exhale for each of the two dolphins involved in synchronous breathing episodes for female pairs were smaller than for male pairs, and time differences for adult pairs were smaller than subadult pairs. These results suggest that age and sex class influenced the characteristics of this behaviour. 2009 Elsevier B.V. All rights reserved.

  18. Heart rate autonomic regulation system at rest and during paced breathing among patients with CRPS as compared to age-matched healthy controls.

    PubMed

    Bartur, Gadi; Vatine, Jean-Jacques; Raphaely-Beer, Noa; Peleg, Sara; Katz-Leurer, Michal

    2014-09-01

    The objective of this study is to assess the autonomic nerve heart rate regulation system at rest and its immediate response to paced breathing among patients with complex regional pain syndrome (CRPS) as compared with age-matched healthy controls. Quasiexperimental. Outpatient clinic. Ten patients with CRPS and 10 age- and sex-matched controls. Participants underwent Holter ECG (NorthEast Monitoring, Inc., Maynard, MA, USA) recording during rest and biofeedback-paced breathing session. Heart rate variability (HRV), time, and frequency measures were assessed. HRV and time domain values were significantly lower at rest among patients with CRPS as compared with controls. A significant association was noted between pain rank and HRV frequency measures at rest and during paced breathing; although both groups reduced breathing rate significantly during paced breathing, HRV time domain parameters increased only among the control group. The increased heart rate and decreased HRV at rest in patients with CRPS suggest a general autonomic imbalance. The inability of the patients to increase HRV time domain values during paced breathing may suggest that these patients have sustained stress response with minimal changeability in response to slow-paced breathing stimuli. Wiley Periodicals, Inc.

  19. Breath biomarkers in toxicology.

    PubMed

    Pleil, Joachim D

    2016-11-01

    Exhaled breath has joined blood and urine as a valuable resource for sampling and analyzing biomarkers in human media for assessing exposure, uptake metabolism, and elimination of toxic chemicals. This article focuses current use of exhaled gas, aerosols, and vapor in human breath, the methods for collection, and ultimately the use of the resulting data. Some advantages of breath are the noninvasive and self-administered nature of collection, the essentially inexhaustible supply, and that breath sampling does not produce potentially infectious waste such as needles, wipes, bandages, and glassware. In contrast to blood and urine, breath samples can be collected on demand in rapid succession and so allow toxicokinetic observations of uptake and elimination in any time frame. Furthermore, new technologies now allow capturing condensed breath vapor directly, or just the aerosol fraction alone, to gain access to inorganic species, lung pH, proteins and protein fragments, cellular DNA, and whole microorganisms from the pulmonary microbiome. Future applications are discussed, especially the use of isotopically labeled probes, non-targeted (discovery) analysis, cellular level toxicity testing, and ultimately assessing "crowd breath" of groups of people and the relation to dose of airborne and other environmental chemicals at the population level.

  20. Effects of hypercapnia and hypoxemia on fetal breathing after decortication.

    PubMed

    Ioffe, S; Jansen, A H; Chernick, V

    1986-09-01

    The effects of hypercapnia and hypoxemia on breathing movements were studied in 12 chronically decorticated fetal sheep, 127-140 days gestation. The fetal state of consciousness was defined in terms of activity of the lateral rectus and nuchal muscles. Arterial blood pressure was monitored. Fetal breathing was determined by integrated diaphragmatic electromyogram (EMG) and analyzed in terms of inspiratory time (TI), expiratory time (TE), electrical equivalent of tidal volume (EVT), breath interval (TT), duty cycle (TI/TT), mean inspiratory flow equivalent (EVT/TI), and instantaneous ventilation equivalent (EVT/TT). Fetal breathing occurred only during episodes of rapid-eye movements, and the response to hypercapnia consisted of an increase in EVT, TI, EVE, and EVT/TI and a decrease in the coefficient of variation of all measured parameters. Induction of hypoxia during episodes of spontaneous fetal breathing produced a decrease in the rate of breathing and an increase in EVT and TI with no change in the variability of all parameters studied. Since similar responses to hypercapnia and hypoxemia are seen in the intact fetus, we conclude that the cerebral cortex has no obvious effect on the chemical control of fetal breathing.

  1. Leukotriene-B4 concentrations in exhaled breath condensate and lung function after thirty minutes of breathing technically dried compressed air.

    PubMed

    Neubauer, Birger; Struck, Niclas; Mutzbauer, Till S; Schotte, Ulrich; Langfeldt, Norbert; Tetzlaff, Kay

    2002-01-01

    In previous studies it had been shown that leukotriene-B4 [LTB4] concentrations in the exhaled breath mirror the inflammatory activity of the airways if the respiratory tract has been exposed to occupational hazards. In diving the respiratory tract is exposed to cold and dry air and the nasopharynx, as the site of breathing-gas warming and humidification, is bypassed. The aim of the present study was to obtain LTB4-concentrations in the exhaled breath and spirometric data of 17 healthy subjects before and after thirty minutes of technically dried air breathing at normobar ambient pressure. The exhaled breath was collected non-invasively, via a permanently cooled expiration tube. The condensate was measured by a standard enzyme immunoassay for LTB4. Lung function values (FVC, FEV1, MEF 25, MEF 50) were simultaneously obtained by spirometry. The measured pre- and post-exposure LTB4- concentrations as well as the lung function values were in the normal range. The present data gave no evidence for any inflammatory activity in the subjects' airways after thirty minutes breathing technically dried air.

  2. Breath acetone monitoring by portable Si:WO3 gas sensors

    PubMed Central

    Righettoni, Marco; Tricoli, Antonio; Gass, Samuel; Schmid, Alex; Amann, Anton; Pratsinis, Sotiris E.

    2013-01-01

    Breath analysis has the potential for early stage detection and monitoring of illnesses to drastically reduce the corresponding medical diagnostic costs and improve the quality of life of patients suffering from chronic illnesses. In particular, the detection of acetone in the human breath is promising for non-invasive diagnosis and painless monitoring of diabetes (no finger pricking). Here, a portable acetone sensor consisting of flame-deposited and in situ annealed, Si-doped epsilon-WO3 nanostructured films was developed. The chamber volume was miniaturized while reaction-limited and transport-limited gas flow rates were identified and sensing temperatures were optimized resulting in a low detection limit of acetone (~20 ppb) with short response (10–15 s) and recovery times (35–70 s). Furthermore, the sensor signal (response) was robust against variations of the exhaled breath flow rate facilitating application of these sensors at realistic relative humidities (80–90%) as in the human breath. The acetone content in the breath of test persons was monitored continuously and compared to that of state-of-the-art proton transfer reaction mass spectrometry (PTR-MS). Such portable devices can accurately track breath acetone concentration to become an alternative to more elaborate breath analysis techniques. PMID:22790702

  3. Determination of breath isoprene and acetone concentration with a needle-type extraction device in gas chromatography-mass spectrometry.

    PubMed

    Ueta, Ikuo; Mizuguchi, Ayako; Okamoto, Mitsuyoshi; Sakamaki, Hiroyuki; Hosoe, Masahiko; Ishiguro, Motoyuki; Saito, Yoshihiro

    2014-03-20

    Isoprene in human breath is said to be related to cholesterol metabolism, and the possibility of the correlations with some clinical parameters has been studied. However, at this stage, no clear benefit of breath isoprene has been reported for clinical diagnosis. In this work, isoprene and acetone concentrations were measured in the breath of healthy and obese subjects using a needle-type extraction device for subsequent analysis in gas chromatography-mass spectrometry (GC-MS) to investigate the possibility of these compounds as an indicator of possible diseases. After measuring intraday and interday variations of isoprene and acetone concentrations in breath samples of healthy subjects, their concentrations were also determined in 80 healthy and 17 obese subjects. In addition, correlation between these breath concentrations and the blood tests result was studied for these healthy and obese subjects. The results indicated successful determination of breath isoprene and acetone in this work, however, no clear correlation was observed between these measured values and the blood test results. Breath isoprene concentration may not be a useful indicator for obesity or hypercholesterolemia. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Association between the rapid shallow breathing index and extubation success in patients with traumatic brain injury

    PubMed Central

    dos Reis, Helena França Correia; Almeida, Mônica Lajana Oliveira; da Silva, Mário Ferreira; Moreira, Julião Oliveira; Rocha, Mário de Seixas

    2013-01-01

    Objective To investigate the association between the rapid shallow breathing index and successful extubation in patients with traumatic brain injury. Methods This study was a prospective study conducted in patients with traumatic brain injury of both genders who underwent mechanical ventilation for at least two days and who passed a spontaneous breathing trial. The minute volume and respiratory rate were measured using a ventilometer, and the data were used to calculate the rapid shallow breathing index (respiratory rate/tidal volume). The dependent variable was the extubation outcome: reintubation after up to 48 hours (extubation failure) or not (extubation success). The independent variable was the rapid shallow breathing index measured after a successful spontaneous breathing trial. Results The sample comprised 119 individuals, including 111 (93.3%) males. The average age of the sample was 35.0±12.9 years old. The average duration of mechanical ventilation was 8.1±3.6 days. A total of 104 (87.4%) participants achieved successful extubation. No association was found between the rapid shallow breathing index and extubation success. Conclusion The rapid shallow breathing index was not associated with successful extubation in patients with traumatic brain injury. PMID:24213084

  5. Can Handling E85 Motor Fuel Cause Positive Breath Alcohol Test Results?

    PubMed Central

    Ran, Ran; Mullins, Michael E.

    2013-01-01

    Hand-held breath alcohol analyzers are widely used by police in traffic stops of drivers suspected of driving while intoxicated (DWI). E85 is a motor fuel consisting of 85% ethanol and 15% gasoline or other hydrocarbons, and is available at nearly 2,600 stations in the USA. We sought to determine whether handling E85 fuel could produce measurable breath alcohol results using a hand-held analyzer and to see if this would be a plausible explanation for a positive breath alcohol test. Five healthy adult subjects dispensed or transferred 8 US gallons of E85 fuel in each of four scenarios. We measured breath alcohol concentration in g/210 L of exhaled breath using the BACTrack S50 at 0, 2, 4, 6, 8, 10, 15 and 20 min after each fuel-handling scenario. Most of the subjects had no detectable breath alcohol after handling E85 motor fuel. Transient elevations (0.02–0.04 g/210 L) in breath alcohol measurement occurred up to 6 min after handling E85 in a minority of subjects. We conclude that it is unlikely that handling E85 motor fuel would result in erroneous prosecution for DWI. PMID:23843422

  6. Frequency of Respiratory Nursing Diagnoses and Accuracy of Clinical Indicators in Preterm Infants.

    PubMed

    Avena, Marta José; Pedreira, Mavilde da Luz Gonçalves; Bassolli de Oliveira Alves, Lucas; Herdman, T Heather; de Gutiérrez, Maria Gaby Rivero

    2018-03-05

    To identify the frequency of the nursing diagnoses, ineffective breathing pattern, impaired gas exchange and impaired spontaneous ventilation in newborns; and, to analyze the accuracy of diagnostic indicators identified for each of these diagnoses. This was a cross-sectional study conducted with a nonprobability sample of 92 infants. Data collected were represented by demographic and clinical variables, clinical indicators of the three respiratory nursing diagnoses from NANDA International, and were analyzed according to frequency and agreement between pairs of expert nurses (Kappa). Ineffective breathing pattern was identified in 74.5% of infants; impaired gas exchange was noted in 31.5%; impaired spontaneous ventilation was found in 16.8% of subjects. Use of accessory muscles to breathe showed the highest sensitivity for ineffective breathing pattern; abnormal blood gases had the best predictive value for impaired gas exchange. Use of accessory muscles to breathe had the highest sensitivity for impaired spontaneous ventilation. Ineffective breathing pattern was the most frequently identified; use of accessory muscles, alteration in depth of breathing, abnormal breathing, and dyspnea were the most representative signs/symptoms. Early recognition of respiratory conditions can support safe interventions to ensure appropriate outcomes. © 2018 NANDA International, Inc.

  7. Bedside diagnosis of alcohol intoxication with a pocket-size breath-alcohol device: sampling from unconscious subjects and specificity for ethanol.

    PubMed

    Falkensson, M; Jones, W; Sörbo, B

    1989-06-01

    We describe a novel mouth-cup device for sampling breath from unconscious subjects and analysis with a hand-held breath-alcohol instrument, the "Alcolmeter SD-2." This equipment was evaluated in healthy volunteers after they drank a moderate dose of alcohol. Three kinds of breath were analyzed: (a) end-expired air from a conventional mouth-tube, (b) breath sampled from the mouth-cup, and (c) air from a nasal tube supplied with the breath analyzer. The ethanol concentration in breath from the mouth-cup was slightly less than in end-expired air but significantly greater than in nasal air. Results with mouth-tube and mouth-cup correlated highly with blood-ethanol concentration as determined by gas chromatography; nasal-tube air correlated less well. The Alcolmeter responded not only to ethanol but also to methanol, 1-propanol, and 2-propanol, whereas ethylene glycol gave no response. The time-response curve for methanol was different, and this might permit differential diagnosis of methanol poisoning.

  8. The effect of simulated air conditions on N95 filtering facepiece respirators performance.

    PubMed

    Ramirez, Joel A; O'Shaughnessy, Patrick T

    2016-07-01

    The objective of this study was to determine the effect of several simulated air environmental conditions on the particle penetration and the breathing resistance of two N95 filtering facepiece respirator (FFR) models. The particle penetration and breathing resistance of the respirators were evaluated in a test system developed to mimic inhalation and exhalation breathing while relative humidity and temperature were modified. Breathing resistance was measured over 120 min using a calibrated pressure transducer under four different temperature and relative humidity conditions without aerosol loading. Particle penetration was evaluated before and after the breathing resistance test at room conditions using a sodium chloride aerosol measured with a scanning mobility particle sizer. Results demonstrated that increasing relative humidity and lowering external temperature caused significant increases in breathing resistance (p < 0.001). However, these same conditions did not influence the penetration or most penetrating particle size of the tested FFRs. The increase in breathing resistance varied by FFR model suggesting that some FFR media are less influenced by high relative humidity.

  9. Neural control of breathing and CO2 homeostasis

    PubMed Central

    Guyenet, P.G.; Bayliss, D.A

    2015-01-01

    Summary Recent advances have clarified how the brain detects CO2 to regulate breathing (central respiratory chemoreception). These mechanisms are reviewed and their significance is presented in the general context of CO2/pH homeostasis through breathing. At rest, respiratory chemoreflexes initiated at peripheral and central sites mediate rapid stabilization of arterial PCO2 and pH. Specific brainstem neurons (e.g., retrotrapezoid nucleus, RTN; serotonergic) are activated by PCO2 and stimulate breathing. RTN neurons detect CO2 via intrinsic proton receptors (TASK-2, GPR4), synaptic input from peripheral chemoreceptors and signals from astrocytes. Respiratory chemoreflexes are arousal state-dependent whereas chemoreceptor stimulation produces arousal. When abnormal, these interactions lead to sleep-disordered breathing. During exercise, “central command” and reflexes from exercising muscles produce the breathing stimulation required to maintain arterial PCO2 and pH despite elevated metabolic activity. The neural circuits underlying central command and muscle afferent control of breathing remain elusive and represent a fertile area for future investigation. PMID:26335642

  10. Bad-breath: Perceptions and misconceptions of Nigerian adults.

    PubMed

    Nwhator, S O; Isiekwe, G I; Soroye, M O; Agbaje, M O

    2015-01-01

    To provide baseline data about bad-breath perception and misconceptions among Nigerian adults. Multi-center cross-sectional study of individuals aged 18-64 years using examiner-administered questionnaires. Age comparisons were based on the model of emerging adults versus full adults. Data were recoded for statistical analyses and univariate and secondary log-linear statistics applied. Participants had lopsided perceptions about bad-breath. While 730 (90.8%) identified the dentist as the expert on halitosis and 719 (89.4%) knew that bad-breath is not contagious, only 4.4% and 2.5% associated bad-breath with tooth decay and gum disease respectively. There were no significant sex differences but the older adults showed better knowledge in a few instances. Most respondents (747, 92.9%) would tell a spouse about their bad-breath and 683 (85%) would tell a friend. Participants had lop-sided knowledge and perceptions about bad-breath. Most Nigerian adults are their "brothers' keepers" who would tell a spouse or friend about their halitosis so they could seek treatment.

  11. The interdependence of excitation and inhibition for the control of dynamic breathing rhythms.

    PubMed

    Baertsch, Nathan Andrew; Baertsch, Hans Christopher; Ramirez, Jan Marino

    2018-02-26

    The preBötzinger Complex (preBötC), a medullary network critical for breathing, relies on excitatory interneurons to generate the inspiratory rhythm. Yet, half of preBötC neurons are inhibitory, and the role of inhibition in rhythmogenesis remains controversial. Using optogenetics and electrophysiology in vitro and in vivo, we demonstrate that the intrinsic excitability of excitatory neurons is reduced following large depolarizing inspiratory bursts. This refractory period limits the preBötC to very slow breathing frequencies. Inhibition integrated within the network is required to prevent overexcitation of preBötC neurons, thereby regulating the refractory period and allowing rapid breathing. In vivo, sensory feedback inhibition also regulates the refractory period, and in slowly breathing mice with sensory feedback removed, activity of inhibitory, but not excitatory, neurons restores breathing to physiological frequencies. We conclude that excitation and inhibition are interdependent for the breathing rhythm, because inhibition permits physiological preBötC bursting by controlling refractory properties of excitatory neurons.

  12. Localized nonlinear waves and dynamical stability in spinor Bose–Einstein condensates with time–space modulation

    NASA Astrophysics Data System (ADS)

    Yao, Yu-Qin; Han, Wei; Li, Ji; Liu, Wu-Ming

    2018-05-01

    Nonlinearity is one of the most remarkable characteristics of Bose–Einstein condensates (BECs). Much work has been done on one- and two-component BECs with time- or space-modulated nonlinearities, while there is little work on spinor BECs with space–time-modulated nonlinearities. In the present paper we investigate localized nonlinear waves and dynamical stability in spinor Bose–Einstein condensates with nonlinearities dependent on time and space. We solve the three coupled Gross–Pitaevskii equations by similarity transformation and obtain two families of exact matter wave solutions in terms of Jacobi elliptic functions and the Mathieu equation. The localized states of the spinor matter wave describe the dynamics of vector breathing solitons, moving breathing solitons, quasi-breathing solitons and resonant solitons. The results show that one-order vector breathing solitons, quasi-breathing solitons, resonant solitons and the moving breathing solitons ψ ±1 are all stable, but the moving breathing soliton ψ 0 is unstable. We also present the experimental parameters to realize these phenomena in future experiments.

  13. sup 14 C-urea breath test for the detection of Helicobacter pylori

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Veldhuyzen van Zanten, S.J.; Tytgat, K.M.; Hollingsworth, J.

    1990-04-01

    The high urease activity of Helicobacter pylori can be used to detect this bacterium by noninvasive breath tests. We have developed a {sup 14}C-urea breath test which uses 5 microCi {sup 14}C with 50 mg nonradioactive urea. Breath samples are collected at baseline and every 30 min for 2 h. Our study compared the outcome of the breath test to the results of histology and culture of endoscopically obtained gastric biopsies in 84 patients. The breath test discriminated well between the 50 positive patients and the 34 patients negative for Helicobacter pylori: the calculated sensitivity was 100%, specificity 88%, positivemore » predictive value 93%, and negative predictive value 100%. Treatment with bismuth subsalicylate and/or ampicillin resulted in lower counts of exhaled {sup 14}CO{sub 2} which correlated with histological improvement in gastritis. The {sup 14}C-urea breath test is a better gold standard for the detection of Helicobacter pylori than histology and/or culture.« less

  14. Minimizing Shortness of Breath

    MedlinePlus

    ... and hyperventilation as well as factors like emotional stress, overexertion, habitual postures and exposure to environmental irritants. Pursed-Lip Breathing One focus of occupational therapy is to teach pursed-lip breathing. This ...

  15. Hydrocarbon pneumonia

    MedlinePlus

    ... pneumonia is caused by drinking or breathing in gasoline , kerosene , furniture polish , paint thinner, or other oily ... Arterial blood gas monitoring Breathing support, including oxygen, inhalation treatment, breathing tube and ventilator (machine), in severe ...

  16. Effect of Nonlinear Gradient Terms on Breathing Localized Solutions in the Quintic Complex Ginzburg-Landau Equation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deissler, R.J.; Brand, H.R.; Deissler, R.J.

    1998-11-01

    We study the effect of nonlinear gradient terms on breathing localized solutions in the complex Ginzburg-Landau equation. It is found that even small nonlinear gradient terms{emdash}which appear at the same order as the quintic term{emdash}can cause dramatic changes in the behavior of the solution, such as causing opposite sides of an otherwise monoperiodic symmetrically breathing solution to breathe at different frequencies, thus causing the solution to breathe periodically or chaotically on only one side or the solution to rapidly spread. {copyright} {ital 1998} {ital The American Physical Society }

  17. Probing plasmonic breathing modes optically

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krug, Markus K., E-mail: markus.krug@uni-graz.at; Reisecker, Michael; Hohenau, Andreas

    2014-10-27

    The confinement of surface plasmon modes in flat nanoparticles gives rise to plasmonic breathing modes. With a vanishing net dipole moment, breathing modes do not radiate, i.e., they are optically dark. Having thus escaped optical detection, breathing modes were only recently revealed in silver nanodisks with electron energy loss spectroscopy in an electron microscope. We show that for disk diameters >200 nm, retardation induced by oblique optical illumination relaxes the optically dark character. This makes breathing modes and thus the full plasmonic mode spectrum accessible to optical spectroscopy. The experimental spectroscopy data are in excellent agreement with numerical simulations.

  18. Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

    NASA Technical Reports Server (NTRS)

    Milwee, W. I., Jr.

    1972-01-01

    Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

  19. Reproducible deep-inspiration breath-hold irradiation with forward intensity-modulated radiotherapy for left-sided breast cancer significantly reduces cardiac radiation exposure compared to inverse intensity-modulated radiotherapy.

    PubMed

    Bolukbasi, Yasemin; Saglam, Yucel; Selek, Ugur; Topkan, Erkan; Kataria, Anglina; Unal, Zeynep; Alpan, Vildan

    2014-01-01

    To investigate the objective utility of our clinical routine of reproducible deep-inspiration breath-hold irradiation for left-sided breast cancer patients on reducing cardiac exposure. Free-breathing and reproducible deep-inspiration breath-hold scans were evaluated for our 10 consecutive left-sided breast cancer patients treated with reproducible deep-inspiration breath-hold. The study was based on the adjuvant dose of 50 Gy in 25 fractions of 2 Gy/fraction. Both inverse and forward intensity-modulated radiotherapy plans were generated for each computed tomography dataset. Reproducible deep-inspiration breath-hold plans with forward intensity-modulated radiotherapy significantly spared the heart and left anterior descending artery compared to generated free-breathing plans based on mean doses - free-breathing vs reproducible deep-inspiration breath-hold, left ventricle (296.1 vs 94.5 cGy, P = 0.005), right ventricle (158.3 vs 59.2 cGy, P = 0.005), left anterior descending artery (171.1 vs 78.1 cGy, P = 0.005), and whole heart (173.9 vs 66 cGy, P = 0.005), heart V20 (2.2% vs 0%, P = 0.007) and heart V10 (4.2% vs 0.3%, P = 0.007) - whereas they revealed no additional burden on the ipsilateral lung. Reproducible deep-inspiration breath-hold and free-breathing plans with inverse intensity-modulated radiotherapy provided similar organ at risk sparing by reducing the mean doses to the left ventricle, left anterior descending artery, heart, V10-V20 of the heart and right ventricle. However, forward intensity-modulated radiotherapy showed significant reduction in doses to the left ventricle, left anterior descending artery, heart, right ventricle, and contralateral breast (mean dose, 248.9 to 12.3 cGy, P = 0.005). The mean doses for free-breathing vs reproducible deep-inspiration breath-hold of the proximal left anterior descending artery were 1.78 vs 1.08 Gy and of the distal left anterior descending artery were 8.11 vs 3.89 Gy, whereas mean distances to the 50 Gy isodose line of the proximal left anterior descending artery were 6.6 vs 3.3 cm and of the distal left anterior descending artery were 7.4 vs 4.1 cm, with forward intensity-modulated radiotherapy. Overall reduction in mean doses to proximal and distal left anterior descending artery with deep-inspiration breath-hold irradiation was 39% (P = 0.02) and 52% (P = 0.002), respectively. We found a significant reduction of radiation exposure to the contralateral breast, left and right ventricles, as well as of proximal and especially distal left anterior descending artery with the deep-inspiration breath-hold technique with forward intensity-modulated radiotherapy planning.

  20. Rapid shallow breathing

    MedlinePlus

    Tachypnea; Breathing - rapid and shallow; Fast shallow breathing; Respiratory rate - rapid and shallow ... Kraft M. Approach to the patient with respiratory disease. In: ... Elsevier Saunders; 2016:chap 83. McGee S. Respiratory rate and ...

  1. Breath-to-breath hypercapnic response in neonatal rats: temperature dependency of the chemoreflexes and potential implications for breathing stability.

    PubMed

    Cummings, Kevin J; Frappell, Peter B

    2009-07-01

    The breathing of newborns is destabilized by warm temperatures. We hypothesized that in unanesthetized, intact newborn rats, body temperature (T(B)) influences the peripheral chemoreflex response (PCR response) to hypercapnia. To test this, we delivered square-wave challenges of 8% CO(2) in air to postnatal day 4-5 (P4-P5) rats held at a T(B) of 30 degrees C (Cold group, n = 11), 33 degrees C (Cool group, n = 10), and 35 degrees C thermoneutral zone group [thermoneutral zone (TNZ) group, n = 11], while measuring ventilation (Ve) directly with a pneumotach and mask. Cool animals were challenged with 8% CO(2) balanced in either air or hyperoxia (n = 10) to identify the PCR response. Breath-to-breath analysis was performed on 30 room air breaths and every breath of the 1-min CO(2) challenge. As expected, warmer T(B) was associated with an unstable breathing pattern in room air: TNZ animals had a coefficient of variation in Ve (Ve CV%) that was double that of animals held at cooler T(B) (P < 0.001). Hyperoxia markedly suppressed the hypercapnic ventilatory response over the first 10 breaths (or approximately 4 s), suggesting that this domain is dominated by the PCR response. The PCR response (P = 0.03) and total response (P = 0.04) were significantly greater in TNZ animals compared with hypothermic animals. The total response had a significant, negative relationship with Vco(2) (R(2) = 0.53; P < 0.001). Breathing stability was positively related to the total response (R(2) = 0.36; P < 0.001) and to a lesser extent, the PCR response (R(2) = 0.19; P = 0.01) and was negatively related to Vco(2) (R(2) = 0.34; P < 0.001). ANCOVA confirmed a significant effect of T(B) alone on breathing stability (P < 0.01), with no independent effects of Vco(2) (P = 0.41), the PCR response (P = 0.82), or the total Ve response (P = 0.08). Our data suggest that in early postnatal life, the chemoreflex responses to CO(2) are highly influenced by T(B), and while related to breathing stability, are not predictors of stability after accounting for the independent effect of T(B).

  2. Improved workflow for quantification of left ventricular volumes and mass using free-breathing motion corrected cine imaging.

    PubMed

    Cross, Russell; Olivieri, Laura; O'Brien, Kendall; Kellman, Peter; Xue, Hui; Hansen, Michael

    2016-02-25

    Traditional cine imaging for cardiac functional assessment requires breath-holding, which can be problematic in some situations. Free-breathing techniques have relied on multiple averages or real-time imaging, producing images that can be spatially and/or temporally blurred. To overcome this, methods have been developed to acquire real-time images over multiple cardiac cycles, which are subsequently motion corrected and reformatted to yield a single image series displaying one cardiac cycle with high temporal and spatial resolution. Application of these algorithms has required significant additional reconstruction time. The use of distributed computing was recently proposed as a way to improve clinical workflow with such algorithms. In this study, we have deployed a distributed computing version of motion corrected re-binning reconstruction for free-breathing evaluation of cardiac function. Twenty five patients and 25 volunteers underwent cardiovascular magnetic resonance (CMR) for evaluation of left ventricular end-systolic volume (ESV), end-diastolic volume (EDV), and end-diastolic mass. Measurements using motion corrected re-binning were compared to those using breath-held SSFP and to free-breathing SSFP with multiple averages, and were performed by two independent observers. Pearson correlation coefficients and Bland-Altman plots tested agreement across techniques. Concordance correlation coefficient and Bland-Altman analysis tested inter-observer variability. Total scan plus reconstruction times were tested for significant differences using paired t-test. Measured volumes and mass obtained by motion corrected re-binning and by averaged free-breathing SSFP compared favorably to those obtained by breath-held SSFP (r = 0.9863/0.9813 for EDV, 0.9550/0.9685 for ESV, 0.9952/0.9771 for mass). Inter-observer variability was good with concordance correlation coefficients between observers across all acquisition types suggesting substantial agreement. Both motion corrected re-binning and averaged free-breathing SSFP acquisition and reconstruction times were shorter than breath-held SSFP techniques (p < 0.0001). On average, motion corrected re-binning required 3 min less than breath-held SSFP imaging, a 37% reduction in acquisition and reconstruction time. The motion corrected re-binning image reconstruction technique provides robust cardiac imaging that can be used for quantification that compares favorably to breath-held SSFP as well as multiple average free-breathing SSFP, but can be obtained in a fraction of the time when using cloud-based distributed computing reconstruction.

  3. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    DOEpatents

    Duan, Yixiang [Los Alamos, NM; Cao, Wenqing [Los Alamos, NM

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  4. Breathing Monitor Using Dye-Doped Optical Fiber

    NASA Astrophysics Data System (ADS)

    Muto, Shinzo; Fukasawa, Akihiko; Ogawa, Takayuki; Morisawa, Masayuki; Ito, Hiroshi

    1990-08-01

    A new monitoring system of human breathing using umbelliferon dye-doped plastic fiber has been studied. Under UV light pumping, the fiber which was used as a sensor head generates blue fluorescence depending on human expiration. By converting the light signal to electronic pulses, the counting of breathing and real-time monitoring of abnormal breathing such as a heavy cough or a cloggy sputum have easily been obtained.

  5. The MindfulBreather: Motion Guided Mindfulness

    PubMed Central

    Mole, Tom B.; Galante, Julieta; Walker, Iona C.; Dawson, Anna F.; Hannah, Laura A.; Mackeith, Pieter; Ainslie, Mark; Jones, Peter B.

    2017-01-01

    For millennia, humans have focused their attention on the breath to develop mindfulness, but finding a scientific way to harness mindful breathing has proven elusive. Existing attempts to objectively measure and feedback on mindfulness have relied on specialist external hardware including electroencephalograms or respirometers that have been impractical for the majority of people learning to meditate. Consequently, training in the key skill of breath-awareness has lacked practical objective measures and guidance to enhance training. Here, we provide a brief technology report on an invention, The MindfulBreather® that addresses these issues. The technology is available to download embedded in a smartphone app that targets, measures and feedbacks on mindfulness of breathing in realtime to enhance training. The current article outlines only the technological concept with future studies quantifying efficacy, validity and reliability to be reported elsewhere. The MindfulBreather works by generating Motion Guided Mindfulness through interacting gyroscopic and touchscreen sensors in a three phase process: Mindfulness Induction (Phase I) gives standardized instruction to users to place their smartphone on their abdomen, breathe mindfully and to tap only at the peak of their inhalation. The smartphone’s gyroscope detects periodic tilts during breathing to generate sinusoidal waveforms. Waveform-tap patterns are analyzed to determine whether the user is mindfully tapping only at the correct phase of the breathing cycle, indicating psychobiological synchronization. Mindfulness Maintenance (Phase II) provides reinforcing pleasant feedback sounds each time a breath is mindfully tapped at the right time, and the App records a mindful breath. Lastly, data-driven Insights are fed back to the user (Phase III), including the number of mindful breaths tapped and breathing rate reductions associated with parasympathetic engagement during meditation. The new MGM technology is then evaluated and contrasted with traditional mindfulness approaches and a novel Psychobiological Synchronization Model is proposed. In summary, unlike existing technology, the MindfulBreather requires no external hardware and repurposes regular smartphones to deliver app-embedded Motion-Guided Mindfulness. Technological applications include reducing mindwandering and down-regulation of the brain’s default mode through enhanced mindful awareness. By objectively harnessing breath awareness, The MindfulBreather aims to realize the ancient human endeavor of mindfulness for the 21st century. PMID:29326571

  6. Can Blood Gas and Acid-Base Parameters at Maximal 200 Meters Front Crawl Swimming be Different Between Former Competitive and Recreational Swimmers?

    PubMed Central

    Kapus, Jernej; Usaj, Anton; Strumbelj, Boro; Kapus, Venceslav

    2008-01-01

    The aim of the present study was to ascertain whether maximal 200 m front crawl swimming strategies and breathing patterns influenced blood gas and acid-base parameters in a manner which gives advantage to former competitive swimmers in comparison with their recreational colleagues. Twelve former competitive male swimmers (the CS group) and nine recreational male swimmers (the RS group) performed a maximal 200 m front crawl swimming with self- selected breathing pattern. Stroke rate (SR) and breathing frequency (BF) were measured during the swimming test. Measures also included blood lactate concentration ([LA]) and parameters of blood acid-base status before and during the first minute after the swimming test. The CS group swam faster then the RS group. Both groups have similar and steady SR throughout the swimming test. This was not matched by similar BF in the CS group but matched it very well in the RS group (r = 0.89). At the beginning of swimming test the CS group had low BF, but they increased it throughout the swimming test. The BF at the RS group remained constant with only mirror variations throughout the swimming test. Such difference in velocity and breathing resulted in maintaining of blood Po2 from hypoxia and Pco2 from hypercapnia. This was similar in both groups. [LA] increased faster in the CS group than in the RS group. On the contrary, the rate of pH decrease remained similar in both groups. The former competitive swimmers showed three possible advantages in comparison to recreational swimmers during maximal 200 m front crawl swimming: a more dynamic and precise regulation of breathing, more powerful bicarbonate buffering system and better synchronization between breathing needs and breathing response during swimming. Key pointsTraining programs for competitive swimmers should promote adaptations to maximal efforts.Those adaptations should include high and maximal intensity swims with controlled breathing frequency (taking breath every fourth, fifth, sixth or eighth stroke cycle for front crawl swimming).Such training will improve breathing regulation in order to impose a better synchronization between breathing needs and breathing response during maximal swimming. PMID:24150142

  7. The MindfulBreather: Motion Guided Mindfulness.

    PubMed

    Mole, Tom B; Galante, Julieta; Walker, Iona C; Dawson, Anna F; Hannah, Laura A; Mackeith, Pieter; Ainslie, Mark; Jones, Peter B

    2017-01-01

    For millennia, humans have focused their attention on the breath to develop mindfulness, but finding a scientific way to harness mindful breathing has proven elusive. Existing attempts to objectively measure and feedback on mindfulness have relied on specialist external hardware including electroencephalograms or respirometers that have been impractical for the majority of people learning to meditate. Consequently, training in the key skill of breath-awareness has lacked practical objective measures and guidance to enhance training. Here, we provide a brief technology report on an invention, The MindfulBreather ® that addresses these issues. The technology is available to download embedded in a smartphone app that targets, measures and feedbacks on mindfulness of breathing in realtime to enhance training. The current article outlines only the technological concept with future studies quantifying efficacy, validity and reliability to be reported elsewhere. The MindfulBreather works by generating Motion Guided Mindfulness through interacting gyroscopic and touchscreen sensors in a three phase process: Mindfulness Induction (Phase I) gives standardized instruction to users to place their smartphone on their abdomen, breathe mindfully and to tap only at the peak of their inhalation. The smartphone's gyroscope detects periodic tilts during breathing to generate sinusoidal waveforms. Waveform-tap patterns are analyzed to determine whether the user is mindfully tapping only at the correct phase of the breathing cycle, indicating psychobiological synchronization. Mindfulness Maintenance (Phase II) provides reinforcing pleasant feedback sounds each time a breath is mindfully tapped at the right time, and the App records a mindful breath. Lastly, data-driven Insights are fed back to the user (Phase III), including the number of mindful breaths tapped and breathing rate reductions associated with parasympathetic engagement during meditation. The new MGM technology is then evaluated and contrasted with traditional mindfulness approaches and a novel Psychobiological Synchronization Model is proposed. In summary, unlike existing technology, the MindfulBreather requires no external hardware and repurposes regular smartphones to deliver app-embedded Motion-Guided Mindfulness. Technological applications include reducing mindwandering and down-regulation of the brain's default mode through enhanced mindful awareness. By objectively harnessing breath awareness, The MindfulBreather aims to realize the ancient human endeavor of mindfulness for the 21st century.

  8. Bench experiments comparing simulated inspiratory effort when breathing helium-oxygen mixtures to that during positive pressure support with air

    PubMed Central

    2012-01-01

    Background Inhalation of helium-oxygen (He/O2) mixtures has been explored as a means to lower the work of breathing of patients with obstructive lung disease. Non-invasive ventilation (NIV) with positive pressure support is also used for this purpose. The bench experiments presented herein were conducted in order to compare simulated patient inspiratory effort breathing He/O2 with that breathing medical air, with or without pressure support, across a range of adult, obstructive disease patterns. Methods Patient breathing was simulated using a dual-chamber mechanical test lung, with the breathing compartment connected to an ICU ventilator operated in NIV mode with medical air or He/O2 (78/22 or 65/35%). Parabolic or linear resistances were inserted at the inlet to the breathing chamber. Breathing chamber compliance was also varied. The inspiratory effort was assessed for the different gas mixtures, for three breathing patterns, with zero pressure support (simulating unassisted spontaneous breathing), and with varying levels of pressure support. Results Inspiratory effort increased with increasing resistance and decreasing compliance. At a fixed resistance and compliance, inspiratory effort increased with increasing minute ventilation, and decreased with increasing pressure support. For parabolic resistors, inspiratory effort was lower for He/O2 mixtures than for air, whereas little difference was measured for nominally linear resistance. Relatively small differences in inspiratory effort were measured between the two He/O2 mixtures. Used in combination, reductions in inspiratory effort provided by He/O2 and pressure support were additive. Conclusions The reduction in inspiratory effort afforded by breathing He/O2 is strongly dependent on the severity and type of airway obstruction. Varying helium concentration between 78% and 65% has small impact on inspiratory effort, while combining He/O2 with pressure support provides an additive reduction in inspiratory effort. In addition, breathing He/O2 alone may provide an alternative to pressure support in circumstances where NIV is not available or poorly tolerated. PMID:23031537

  9. The physiological effects of slow breathing in the healthy human

    PubMed Central

    Russo, Marc A.; Santarelli, Danielle M.; O’Rourke, Dean

    2017-01-01

    Slow breathing practices have been adopted in the modern world across the globe due to their claimed health benefits. This has piqued the interest of researchers and clinicians who have initiated investigations into the physiological (and psychological) effects of slow breathing techniques and attempted to uncover the underlying mechanisms. The aim of this article is to provide a comprehensive overview of normal respiratory physiology and the documented physiological effects of slow breathing techniques according to research in healthy humans. The review focuses on the physiological implications to the respiratory, cardiovascular, cardiorespiratory and autonomic nervous systems, with particular focus on diaphragm activity, ventilation efficiency, haemodynamics, heart rate variability, cardiorespiratory coupling, respiratory sinus arrhythmia and sympathovagal balance. The review ends with a brief discussion of the potential clinical implications of slow breathing techniques. This is a topic that warrants further research, understanding and discussion. Key points Slow breathing practices have gained popularity in the western world due to their claimed health benefits, yet remain relatively untouched by the medical community. Investigations into the physiological effects of slow breathing have uncovered significant effects on the respiratory, cardiovascular, cardiorespiratory and autonomic nervous systems. Key findings include effects on respiratory muscle activity, ventilation efficiency, chemoreflex and baroreflex sensitivity, heart rate variability, blood flow dynamics, respiratory sinus arrhythmia, cardiorespiratory coupling, and sympathovagal balance. There appears to be potential for use of controlled slow breathing techniques as a means of optimising physiological parameters that appear to be associated with health and longevity, and that may extend to disease states; however, there is a dire need for further research into the area. Educational aims To provide a comprehensive overview of normal human respiratory physiology and the documented effects of slow breathing in healthy humans. To review and discuss the evidence and hypotheses regarding the mechanisms underlying slow breathing physiological effects in humans. To provide a definition of slow breathing and what may constitute “autonomically optimised respiration”. To open discussion on the potential clinical implications of slow breathing techniques and the need for further research. PMID:29209423

  10. Clinical utility of breath ammonia for evaluation of ammonia physiology in healthy and cirrhotic adults

    PubMed Central

    Spacek, Lisa A; Mudalel, Matthew; Tittel, Frank; Risby, Terence H; Solga, Steven F

    2016-01-01

    Blood ammonia is routinely used in clinical settings to assess systemic ammonia in hepatic encephalopathy and urea cycle disorders. Despite its drawbacks, blood measurement is often used as a comparator in breath studies because it is a standard clinical test. We sought to evaluate sources of measurement error and potential clinical utility of breath ammonia compared to blood ammonia. We measured breath ammonia in real time by quartz enhanced photoacoustic spectrometry and blood ammonia in 10 healthy and 10 cirrhotic participants. Each participant contributed 5 breath samples and blood for ammonia measurement within 1 h. We calculated the coefficient of variation (CV) for 5 breath ammonia values, reported medians of healthy and cirrhotic participants, and used scatterplots to display breath and blood ammonia. For healthy participants, mean age was 22 years (±4), 70% were men, and body mass index (BMI) was 27 (±5). For cirrhotic participants, mean age was 61 years (±8), 60% were men, and BMI was 31 (±7). Median blood ammonia for healthy participants was within normal range, 10 μmol L−1 (interquartile range (IQR), 3–18) versus 46 μmol L−1 (IQR, 23–66) for cirrhotic participants. Median breath ammonia was 379 pmol mL−1 CO2 (IQR, 265–765) for healthy versus 350 pmol mL−1 CO2 (IQR, 180–1013) for cirrhotic participants. CV was 17 ± 6%. There remains an important unmet need in the evaluation of systemic ammonia, and breath measurement continues to demonstrate promise to fulfill this need. Given the many differences between breath and blood ammonia measurement, we examined biological explanations for our findings in healthy and cirrhotic participants. We conclude that based upon these preliminary data breath may offer clinically important information this is not provided by blood ammonia. PMID:26658550

  11. Effect of mask dead space and occlusion of mask holes on delivery of nebulized albuterol.

    PubMed

    Berlinski, Ariel

    2014-08-01

    Infants and children with respiratory conditions are often prescribed bronchodilators. Face masks are used to facilitate the administration of nebulized therapy in patients unable to use a mouthpiece. Masks incorporate holes into their design, and their occlusion during aerosol delivery has been a common practice. Masks are available in different sizes and different dead volumes. The aim of this study was to compare the effect of different degrees of occlusion of the mask holes and different mask dead space on the amount of nebulized albuterol available at the mouth opening in a model of a spontaneously breathing child. A breathing simulator mimicking infant (tidal volume [VT] = 50 mL, breathing frequency = 30 breaths/min, inspiratory-expiratory ratio [I:E] = 1:3), child (VT = 155 mL, breathing frequency = 25 breaths/min, I:E = 1:2), and adult (VT = 500 mL, breathing frequency = 15 breaths/min, I:E = 1:2) breathing patterns was connected to a collection filter hidden behind a face plate. A pediatric size mask and an adult size mask connected to a continuous output jet nebulizer were sealed to the face plate. Three nebulizers were loaded with albuterol sulfate (2.5 mg/3 mL) and operated with 6 L/min compressed air for 5 min. Experiments were repeated with different degrees of occlusion (0%, 50%, and 90%). Albuterol was extracted from the filter and measured with a spectrophotometer at 276 nm. Occlusion of the holes in the large mask did not increase the amount of albuterol in any of the breathing patterns. The amount of albuterol captured at the mouth opening did not change when the small mask was switched to the large mask, except with the breathing pattern of a child, and when the holes in the mask were 50% occluded (P = .02). Neither decreasing the dead space of the mask nor occluding the mask holes increased the amount of nebulized albuterol captured at the mouth opening.

  12. SU-E-J-185: A Systematic Review of Breathing Guidance in Radiation Oncology and Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pollock, S; Keall, P; Keall, R

    Purpose: The advent of image-guided radiation therapy (IGRT) has led to dramatic improvements in the accuracy of treatment delivery in radiotherapy. Such advancements have highlighted the deleterious impact tumor motion can have on both image quality and radiation treatment delivery. One approach to reducing tumor motion is the use of breathing guidance systems during imaging and treatment. A review of such research had not yet been performed, it was therefore our aim to perform a systematic review of breathing guidance interventions within the fields of radiation oncology and radiology. Methods: Results of online database searches were filtered in accordance tomore » a set of eligibility criteria. The search, filtration, and analysis of articles were conducted in accordance with the PRISMAStatement reporting standard (Preferred Reporting Items for Systematic reviews and Meta-Analyses) utilizing the PICOS approach (Participants, Intervention, Comparison, Outcome, Study design). Participants: Cancer patients, healthy volunteers. Intervention: Biofeedback breathing guidance systems. Comparison: No breathing guidance of the same breathing type. Outcome: Regularity of breathing signal and anatomic/tumor motion, medical image quality, radiation treatment margins and coverage, medical imaging and radiation treatment times. Study design: Quantitative and controlled prospective or retrospective trials. Results: The systematic search yielded a total of 479 articles, which were filtered down to 27 relevant articles in accordance to the eligibility criteria. The vast majority of investigated outcomes were significantly positively impacted by the use of breathing guidance; however, this was dependent upon the nature of the breathing guidance system and study design. In 25/27 studies significant improvements from the use of breathing guidance were observed. Conclusion: The results found here indicate that further clinical studies are warranted which quantify more comprehensively the clinical impact of The results found here indicate that further clinical studies are warranted which quantify more comprehensively the clinical impact of breathing guidance interventions.« less

  13. Reliable quantification of BOLD fMRI cerebrovascular reactivity despite poor breath-hold performance.

    PubMed

    Bright, Molly G; Murphy, Kevin

    2013-12-01

    Cerebrovascular reactivity (CVR) can be mapped using BOLD fMRI to provide a clinical insight into vascular health that can be used to diagnose cerebrovascular disease. Breath-holds are a readily accessible method for producing the required arterial CO2 increases but their implementation into clinical studies is limited by concerns that patients will demonstrate highly variable performance of breath-hold challenges. This study assesses the repeatability of CVR measurements despite poor task performance, to determine if and how robust results could be achieved with breath-holds in patients. Twelve healthy volunteers were scanned at 3 T. Six functional scans were acquired, each consisting of 6 breath-hold challenges (10, 15, or 20 s duration) interleaved with periods of paced breathing. These scans simulated the varying breath-hold consistency and ability levels that may occur in patient data. Uniform ramps, time-scaled ramps, and end-tidal CO2 data were used as regressors in a general linear model in order to measure CVR at the grey matter, regional, and voxelwise level. The intraclass correlation coefficient (ICC) quantified the repeatability of the CVR measurement for each breath-hold regressor type and scale of interest across the variable task performances. The ramp regressors did not fully account for variability in breath-hold performance and did not achieve acceptable repeatability (ICC<0.4) in several regions analysed. In contrast, the end-tidal CO2 regressors resulted in "excellent" repeatability (ICC=0.82) in the average grey matter data, and resulted in acceptable repeatability in all smaller regions tested (ICC>0.4). Further analysis of intra-subject CVR variability across the brain (ICCspatial and voxelwise correlation) supported the use of end-tidal CO2 data to extract robust whole-brain CVR maps, despite variability in breath-hold performance. We conclude that the incorporation of end-tidal CO2 monitoring into scanning enables robust, repeatable measurement of CVR that makes breath-hold challenges suitable for routine clinical practice. © 2013.

  14. eAMI: A Qualitative Quantification of Periodic Breathing Based on Amplitude of Oscillations

    PubMed Central

    Fernandez Tellez, Helio; Pattyn, Nathalie; Mairesse, Olivier; Dolenc-Groselj, Leja; Eiken, Ola; Mekjavic, Igor B.; Migeotte, P. F.; Macdonald-Nethercott, Eoin; Meeusen, Romain; Neyt, Xavier

    2015-01-01

    Study Objectives: Periodic breathing is sleep disordered breathing characterized by instability in the respiratory pattern that exhibits an oscillatory behavior. Periodic breathing is associated with increased mortality, and it is observed in a variety of situations, such as acute hypoxia, chronic heart failure, and damage to respiratory centers. The standard quantification for the diagnosis of sleep related breathing disorders is the apnea-hypopnea index (AHI), which measures the proportion of apneic/hypopneic events during polysomnography. Determining the AHI is labor-intensive and requires the simultaneous recording of airflow and oxygen saturation. In this paper, we propose an automated, simple, and novel methodology for the detection and qualification of periodic breathing: the estimated amplitude modulation index (eAMI). Patients or Participants: Antarctic cohort (3,800 meters): 13 normal individuals. Clinical cohort: 39 different patients suffering from diverse sleep-related pathologies. Measurements and Results: When tested in a population with high levels of periodic breathing (Antarctic cohort), eAMI was closely correlated with AHI (r = 0.95, P < 0.001). When tested in the clinical setting, the proposed method was able to detect portions of the signal in which subclinical periodic breathing was validated by an expert (n = 93; accuracy = 0.85). Average eAMI was also correlated with the loop gain for the combined clinical and Antarctica cohorts (r = 0.58, P < 0.001). Conclusions: In terms of quantification and temporal resolution, the eAMI is able to estimate the strength of periodic breathing and the underlying loop gain at any given time within a record. The impaired prognosis associated with periodic breathing makes its automated detection and early diagnosis of clinical relevance. Citation: Fernandez Tellez H, Pattyn N, Mairesse O, Dolenc-Groselj L, Eiken O, Mekjavic IB, Migeotte PF, Macdonald-Nethercott E, Meeusen R, Neyt X. eAMI: a qualitative quantification of periodic breathing based on amplitude of oscillations. SLEEP 2015;38(3):381–389. PMID:25581914

  15. Investigation of Exhaled Breath Samples from Patients with Alzheimer's Disease Using Gas Chromatography-Mass Spectrometry and an Exhaled Breath Sensor System.

    PubMed

    Lau, Hui-Chong; Yu, Joon-Boo; Lee, Ho-Won; Huh, Jeung-Soo; Lim, Jeong-Ok

    2017-08-03

    Exhaled breath is a body secretion, and the sampling process of this is simple and cost effective. It can be non-invasively collected for diagnostic procedures. Variations in the chemical composition of exhaled breath resulting from gaseous exchange in the extensive capillary network of the body are proposed to be associated with pathophysiological changes. In light of the foreseeable potential of exhaled breath as a diagnostic specimen, we used gas chromatography and mass spectrometry (GC-MS) to study the chemical compounds present in exhaled breath samples from patients with Alzheimer's disease (AD), Parkinson's disease (PD), and from healthy individuals as a control group. In addition, we also designed and developed a chemical-based exhaled breath sensor system to examine the distribution pattern in the patient and control groups. The results of our study showed that several chemical compounds, such as 1-phenantherol and ethyl 3-cyano-2,3-bis (2,5,-dimethyl-3-thienyl)-acrylate, had a higher percentage area in the AD group than in the PD and control groups. These results may indicate an association of these chemical components in exhaled breath with the progression of disease. In addition, in-house fabricated exhaled breath sensor systems, containing several types of gas sensors, showed significant differences in terms of the normalized response of the sensitivity characteristics between the patient and control groups. A subsequent clustering analysis was able to distinguish between the AD patients, PD patients, and healthy individuals using principal component analysis, Sammon's mapping, and a combination of both methods, in particular when using the exhaled breath sensor array system A consisting of eight sensors. With this in mind, the exhaled breath sensor system could provide alternative option for diagnosis and be applied as a useful, effective tool for the screening and diagnosis of AD in the near future.

  16. Comparative analysis between the alveolar recruitment maneuver and breath stacking technique in patients with acute lung injury

    PubMed Central

    Porto, Elias Ferreira; Tavolaro, Kelly Cristiani; Kumpel, Claudia; Oliveira, Fernanda Augusta; Sousa, Juciaria Ferreira; de Carvalho, Graciele Vieira; de Castro, Antonio Adolfo Mattos

    2014-01-01

    Objective To compare the effectiveness of the alveolar recruitment maneuver and the breath stacking technique with respect to lung mechanics and gas exchange in patients with acute lung injury. Methods Thirty patients were distributed into two groups: Group 1 - breath stacking; and Group 2 - alveolar recruitment maneuver. After undergoing conventional physical therapy, all patients received both treatments with an interval of 1 day between them. In the first group, the breath stacking technique was used initially, and subsequently, the alveolar recruitment maneuver was applied. Group 2 patients were initially subjected to alveolar recruitment, followed by the breath stacking technique. Measurements of lung compliance and airway resistance were evaluated before and after the use of both techniques. Gas analyses were collected before and after the techniques were used to evaluate oxygenation and gas exchange. Results Both groups had a significant increase in static compliance after breath stacking (p=0.021) and alveolar recruitment (p=0.03), but with no significant differences between the groups (p=0.95). The dynamic compliance did not increase for the breath stacking (p=0.22) and alveolar recruitment (p=0.074) groups, with no significant difference between the groups (p=0.11). The airway resistance did not decrease for either groups, i.e., breath stacking (p=0.91) and alveolar recruitment (p=0.82), with no significant difference between the groups (p=0.39). The partial pressure of oxygen increased significantly after breath stacking (p=0.013) and alveolar recruitment (p=0.04), but there was no significant difference between the groups (p=0.073). The alveolar-arterial O2 difference decreased for both groups after the breath stacking (p=0.025) and alveolar recruitment (p=0.03) interventions, and there was no significant difference between the groups (p=0.81). Conclusion Our data suggest that the breath stacking and alveolar recruitment techniques are effective in improving the lung mechanics and gas exchange in patients with acute lung injury. PMID:25028951

  17. Comparative analysis between the alveolar recruitment maneuver and breath stacking technique in patients with acute lung injury.

    PubMed

    Porto, Elias Ferreira; Tavolaro, Kelly Cristiani; Kumpel, Claudia; Oliveira, Fernanda Augusta; Sousa, Juciaria Ferreira; Carvalho, Graciele Vieira de; Castro, Antonio Adolfo Mattos de

    2014-01-01

    To compare the effectiveness of the alveolar recruitment maneuver and the breath stacking technique with respect to lung mechanics and gas exchange in patients with acute lung injury. Thirty patients were distributed into two groups: Group 1 - breath stacking; and Group 2 - alveolar recruitment maneuver. After undergoing conventional physical therapy, all patients received both treatments with an interval of 1 day between them. In the first group, the breath stacking technique was used initially, and subsequently, the alveolar recruitment maneuver was applied. Group 2 patients were initially subjected to alveolar recruitment, followed by the breath stacking technique. Measurements of lung compliance and airway resistance were evaluated before and after the use of both techniques. Gas analyses were collected before and after the techniques were used to evaluate oxygenation and gas exchange. Both groups had a significant increase in static compliance after breath stacking (p=0.021) and alveolar recruitment (p=0.03), but with no significant differences between the groups (p=0.95). The dynamic compliance did not increase for the breath stacking (p=0.22) and alveolar recruitment (p=0.074) groups, with no significant difference between the groups (p=0.11). The airway resistance did not decrease for either groups, i.e., breath stacking (p=0.91) and alveolar recruitment (p=0.82), with no significant difference between the groups (p=0.39). The partial pressure of oxygen increased significantly after breath stacking (p=0.013) and alveolar recruitment (p=0.04), but there was no significant difference between the groups (p=0.073). The alveolar-arterial O2 difference decreased for both groups after the breath stacking (p=0.025) and alveolar recruitment (p=0.03) interventions, and there was no significant difference between the groups (p=0.81). Our data suggest that the breath stacking and alveolar recruitment techniques are effective in improving the lung mechanics and gas exchange in patients with acute lung injury.

  18. 21 CFR 868.5270 - Breathing system heater.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. A breathing system heater is a device that is intended to warm breathing gases before they enter a patient's airway. The device may include a temperature controller. (b) Classification. Class II...

  19. Anatomic and Pathologic Variability During Radiotherapy for a Hybrid Active Breath-Hold Gating Technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glide-Hurst, Carri K.; Gopan, Ellen; Department of Radiation Oncology Wayne State University, Detroit, MI

    2010-07-01

    Purpose: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. Methods and Materials: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified. Results: On average, intrafraction variability of lung and GTV centroidmore » position was <2.0 mm. Interfraction population variability was 3.6-6.7 mm (systematic) and 3.1-3.9 mm (random) for the GTV centroid and 1.0-3.3 mm (systematic) and 1.5-2.6 mm (random) for the lungs. Tumor volume regressed 44.6% {+-} 23.2%. Gross tumor volume border variability was patient specific and demonstrated anisotropic shape change in some subjects. Interfraction GTV positional variability was associated with tumor volume regression and contralateral lung volume (p < 0.05). Inter-breath-hold reproducibility was unaffected by time point in the treatment course (p > 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05). Conclusions: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial.« less

  20. Effect of rescue breathing by lay rescuers for out-of-hospital cardiac arrest caused by respiratory disease: a nationwide, population-based, propensity score-matched study.

    PubMed

    Fukuda, Tatsuma; Ohashi-Fukuda, Naoko; Kondo, Yutaka; Sera, Toshiki; Yahagi, Naoki

    2017-06-01

    The importance of respiratory care in cardiopulmonary resuscitation may vary depending on the cause of cardiac arrest. No previous study has investigated the effects of rescue breathing performed by a lay rescuer on the outcomes of patients with out-of-hospital cardiac arrest (OHCA) caused by intrinsic respiratory diseases. The aim of this study was to investigate whether rescue breathing performed by a lay rescuer is associated with outcomes after respiratory disease-related OHCA. In a nationwide, population-based, propensity score-matched study in Japan, among adult patients with OHCA caused by respiratory disease who received bystander cardiopulmonary resuscitation from January 1, 2005 to December 31, 2010, we compared patients with rescue breathing to those without rescue breathing. The primary outcome was neurologically favorable survival 1 month after OHCA. Of the eligible 14,781 patients, 4970 received rescue breathing from a lay rescuer and 9811 did not receive rescue breathing. In a propensity score-matched cohort (4897 vs. 4897 patients), the neurologically favorable survival rate was similar between patients with and without rescue breathing from a lay rescuer [0.9 vs. 0.7 %; OR 1.23 (95 % CI 0.79-1.93)]. Additionally, in subgroup analyses, rescue breathing was not associated with neurological outcome regardless of the type of rescuer [family member: adjusted OR 0.83 (95 % CI 0.39-1.70); or non-family member: adjusted OR 1.91 (95 % CI 0.79-5.35)]. Even among patients with OHCA caused by respiratory disease, rescue breathing performed by a lay rescuer was not associated with neurological outcomes, regardless of the type of lay rescuer.

  1. Objective vs. Subjective Evaluation of Cognitive Performance During 0.4-MPa Dives Breathing Air or Nitrox.

    PubMed

    Germonpré, Peter; Balestra, Costantino; Hemelryck, Walter; Buzzacott, Peter; Lafère, Pierre

    2017-05-01

    Divers try to limit risks associated with their sport, for instance by breathing enriched air nitrox (EANx) instead of air. This double blinded, randomized trial was designed to see if the use of EANx could effectively improve cognitive performance while diving. Eight volunteers performed two no-decompression dry dives breathing air or EANx for 20 min at 0.4 MPa. Cognitive functions were assessed with a computerized test battery, including MathProc and Ptrail. Measurements were taken before the dive, upon arrival and after 15 min at depth, upon surfacing, and at 30 min postdive. After each dive subjects were asked to identify the gas they had just breathed. Identification of the breathing gas was not possible on subjective assessment alone, while cognitive assessments showed significantly better performance while breathing EANx. Before the dives, breathing air, mean time to complete the task was 1795 ms for MathProc and 1905 ms for Ptrail. When arriving at depth MathProc took 1616 ms on air and 1523 ms on EANx, and Ptrail took 1318 ms on air and and 1356 ms on EANx, followed 15 min later by significant performance inhibition while breathing air during the ascent and the postdive phase, supporting the concept of late dive/postdive impairment. The results suggest that EANx could protect against decreased neuro-cognitive performance induced by inert gas narcosis. It was not possible for blinded divers to identify which gas they were breathing and differences in postdive fatigue between air and EANx diving deserve further investigation.Germonpré P, Balestra C, Hemelryck W, Buzzacott P, Lafère P. Objective vs. subjective evaluation of cognitive performance during 0.4-MPa dives breathing air or nitrox. Aerosp Med Hum Perform. 2017; 88(5):469-475.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thrall, Karla D.; Schwartz, Ronald E.; Weitz, Karl K.

    Nasal dosimetry models have become increasingly quantitative as insights into tissue deposition/clearance and computational fluid dynamics have become available. Validation of these models requires sufficient experimental data. However, investigations into respiratory deposition, particularly in human volunteers, have been historically limited due to methodological limitations. To overcome this, a method for evaluating the nasal wash-in, wash-out phenomena of a highly water-soluble compound in human volunteers was developed and characterized. This methodology was assessed using controlled human inhalation exposures to uniformly labeled 13C-acetone at approximately 1 ppm concentration for 30 minutes under different breathing maneuvers (inhale nose/exhale nose; inhale nose/exhale mouth; inhalemore » mouth/exhale nose). A small-diameter air-sampling probe inserted in the nasopharyngeal cavity of the volunteer was connected directly to an ion-trap mass spectrometer capable of sampling every 0.8 sec. A second ion-trap mass spectrometer simultaneously sampled from the volunteer?s exhaled breath stream via a breath-inlet device interface. Together, the two mass spectrometers provided real-time appraisal of the 13C-acetone concentrations in the nasopharyngeal region and in the exhaled breath stream before, during, and after the different breathing maneuvers. The breathing cycle (depth and frequency) and heart rate were concurrently monitored throughout the exposure using a heart rate monitor and a human plethysmograph to differentiate inhalation and exhalation. Graphical overlay of the plethysmography results with the mass spectrometer measurements show clear quantifiable differences in 13C-acetone levels at the nasal probe as a function of breathing maneuvers. Breath-by-breath analysis of 13C-acetone concentrations indicate that between 40-75% of the compound is absorbed upon inhalation and nearly all of that absorbed released back into the breath stream during exhalation.« less

  3. Inhaled hydrogen sulfide: a rapidly reversible inhibitor of cardiac and metabolic function in the mouse.

    PubMed

    Volpato, Gian Paolo; Searles, Robert; Yu, Binglan; Scherrer-Crosbie, Marielle; Bloch, Kenneth D; Ichinose, Fumito; Zapol, Warren M

    2008-04-01

    Breathing hydrogen sulfide (H2S) has been reported to induce a suspended animation-like state with hypothermia and a concomitant metabolic reduction in rodents. However, the impact of H2S breathing on cardiovascular function remains incompletely understood. In this study, the authors investigated the cardiovascular and metabolic effects of inhaled H2S in a murine model. The impact of breathing H2S on cardiovascular function was examined using telemetry and echocardiography in awake mice. The effects of breathing H2S on carbon dioxide production and oxygen consumption were measured at room temperature and in a warmed environment. Breathing H2S at 80 parts per million by volume at 27 degrees C ambient temperature for 6 h markedly reduced heart rate, core body temperature, respiratory rate, and physical activity, whereas blood pressure remained unchanged. Echocardiography demonstrated that H2S exposure decreased both heart rate and cardiac output but preserved stroke volume. Breathing H2S for 6 h at 35 degrees C ambient temperature (to prevent hypothermia) decreased heart rate, physical activity, respiratory rate, and cardiac output without altering stroke volume or body temperature. H2S breathing seems to induce bradycardia by depressing sinus node activity. Breathing H2S for 30 min decreased whole body oxygen consumption and carbon dioxide production at either 27 degrees or 35 degrees C ambient temperature. Both parameters returned to baseline levels within 10 min after the cessation of H2S breathing. Inhalation of H2S at either 27 degrees or 35 degrees C reversibly depresses cardiovascular function without changing blood pressure in mice. Breathing H2S also induces a rapidly reversible reduction of metabolic rate at either body temperature.

  4. Inhaled Hydrogen Sulfide

    PubMed Central

    Volpato, Gian Paolo; Searles, Robert; Yu, Binglan; Scherrer-Crosbie, Marielle; Bloch, Kenneth D.; Ichinose, Fumito; Zapol, Warren M.

    2010-01-01

    Background Breathing hydrogen sulfide (H2S) has been reported to induce a suspended animation–like state with hypothermia and a concomitant metabolic reduction in rodents. However, the impact of H2S breathing on cardiovascular function remains incompletely understood. In this study, the authors investigated the cardiovascular and metabolic effects of inhaled H2S in a murine model. Methods The impact of breathing H2S on cardiovascular function was examined using telemetry and echocardiography in awake mice. The effects of breathing H2S on carbon dioxide production and oxygen consumption were measured at room temperature and in a warmed environment. Results Breathing H2S at 80 parts per million by volume at 27°C ambient temperature for 6 h markedly reduced heart rate, core body temperature, respiratory rate, and physical activity, whereas blood pressure remained unchanged. Echocardiography demonstrated that H2S exposure decreased both heart rate and cardiac output but preserved stroke volume. Breathing H2S for 6 h at 35°C ambient temperature (to prevent hypothermia) decreased heart rate, physical activity, respiratory rate, and cardiac output without altering stroke volume or body temperature. H2S breathing seems to induce bradycardia by depressing sinus node activity. Breathing H2S for 30 min decreased whole body oxygen consumption and carbon dioxide production at either 27° or 35°C ambient temperature. Both parameters returned to baseline levels within 10 min after the cessation of H2S breathing. Conclusions Inhalation of H2S at either 27° or 35°C reversibly depresses cardiovascular function without changing blood pressure in mice. Breathing H2S also induces a rapidly reversible reduction of metabolic rate at either body temperature. PMID:18362598

  5. Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: a bench study.

    PubMed

    Chikata, Yusuke; Oto, Jun; Onodera, Mutsuo; Nishimura, Masaji

    2013-09-01

    Heat and moisture exchangers (HMEs) are commonly used for humidifying respiratory gases administered to mechanically ventilated patients. While they are also applied to tracheostomized patients with spontaneous breathing, their performance in this role has not yet been clarified. We carried out a bench study to investigate the effects of spontaneous breathing parameters and oxygen flow on the humidification performance of 11 HMEs. We evaluated the humidification provided by 11 HMEs for tracheostomized patients, and also by a system delivering high-flow CPAP, and an oxygen mask with nebulizer heater. Spontaneous breathing was simulated with a mechanical ventilator, lung model, and servo-controlled heated humidifier at tidal volumes of 300, 500, and 700 mL, and breathing frequencies of 10 and 20 breaths/min. Expired gas was warmed to 37°C. The high-flow CPAP system was set to deliver 15, 30, and 45 L/min. With the 8 HMEs that were equipped with ports to deliver oxygen, and with the high-flow CPAP system, measurements were taken when delivering 0 and 3 L/min of dry oxygen. After stabilization we measured the absolute humidity (AH) of inspired gas with a hygrometer. AH differed among HMEs applied to tracheostomized patients with spontaneous breathing. For all the HMEs, as tidal volume increased, AH decreased. At 20 breaths/min, AH was higher than at 10 breaths/min. For all the HMEs, when oxygen was delivered, AH decreased to below 30 mg/L. With an oxygen mask and high-flow CPAP, at all settings, AH exceeded 30 mg/L. None of the HMEs provided adequate humidification when supplemental oxygen was added. In the ICU, caution is required when applying HME to tracheostomized patients with spontaneous breathing, especially when supplemental oxygen is required.

  6. Description of Abnormal Breathing Is Associated With Improved Outcomes and Delayed Telephone Cardiopulmonary Resuscitation Instructions.

    PubMed

    Fukushima, Hidetada; Panczyk, Micah; Hu, Chengcheng; Dameff, Christian; Chikani, Vatsal; Vadeboncoeur, Tyler; Spaite, Daniel W; Bobrow, Bentley J

    2017-08-29

    Emergency 9-1-1 callers use a wide range of terms to describe abnormal breathing in persons with out-of-hospital cardiac arrest (OHCA). These breathing descriptors can obstruct the telephone cardiopulmonary resuscitation (CPR) process. We conducted an observational study of emergency call audio recordings linked to confirmed OHCAs in a statewide Utstein-style database. Breathing descriptors fell into 1 of 8 groups (eg, gasping, snoring). We divided the study population into groups with and without descriptors for abnormal breathing to investigate the impact of these descriptors on patient outcomes and telephone CPR process. Callers used descriptors in 459 of 2411 cases (19.0%) between October 1, 2010, and December 31, 2014. Survival outcome was better when the caller used a breathing descriptor (19.6% versus 8.8%, P <0.0001), with an odds ratio of 1.63 (95% confidence interval, 1.17-2.25). After exclusions, 379 of 459 cases were eligible for process analysis. When callers described abnormal breathing, the rates of telecommunicator OHCA recognition, CPR instruction, and telephone CPR were lower than when callers did not use a breathing descriptor (79.7% versus 93.0%, P <0.0001; 65.4% versus 72.5%, P =0.0078; and 60.2% versus 66.9%, P =0.0123, respectively). The time interval between call receipt and OHCA recognition was longer when the caller used a breathing descriptor (118.5 versus 73.5 seconds, P <0.0001). Descriptors of abnormal breathing are associated with improved outcomes but also with delays in the identification of OHCA. Familiarizing telecommunicators with these descriptors may improve the telephone CPR process including OHCA recognition for patients with increased probability of survival. © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  7. The effect of CO2 on ventilation and breath-holding during exercise and while breathing through an added resistance.

    PubMed

    Clark, T J; Godfrey, S

    1969-05-01

    1. Ventilation was measured while subjects were made to rebreathe from a bag containing CO(2) and O(2) in order to expose them to a steadily rising CO(2) tension (P(CO2)). The object of the experiments was to determine the effect of a variety of stimuli upon the increase in ventilation and fall in breath-holding time which occurs in response to the rising P(CO2).2. Steady-state exercise at 200 kg.m/min resulted in a small fall in the slope of the ventilation-CO(2) response curve (S(V)) and a small, though not statistically significant, fall in the P(CO2) at which ventilation would be zero by extrapolation (B(V)). There was a marked fall in the slope of the breath-holding-CO(2) response curve (S(BH)) and an increase in the P(CO2) at which breath-holding time became zero by extrapolation (B(BH)).3. These results have been interpreted with the aid of a model of the control of breath-holding and it is suggested that there is no change in CO(2) sensitivity on exercise, either during rebreathing or breath-holding.4. An increase in the resistance to breathing caused a marked reduction in S(V) and B(V), but no change in the breath-holding-CO(2) response curve. These findings suggest that the flattening of the ventilation-CO(2) response curve is mechanical in origin and acute airway obstruction produces no change in CO(2) sensitivity.5. On the basis of these results, we suggest that more information about CO(2) sensitivity can be obtained by a combination of ventilation and breath-holding-CO(2) response curves.

  8. Balancing the competing requirements of air-breathing and display behaviour during male-male interactions in Siamese fighting fish Betta splendens.

    PubMed

    Alton, Lesley A; Portugal, Steven J; White, Craig R

    2013-02-01

    Air-breathing fish of the Anabantoidei group meet their metabolic requirements for oxygen through both aerial and aquatic gas exchange. Siamese fighting fish Betta splendens are anabantoids that frequently engage in aggressive male-male interactions which cause significant increases in metabolic rate and oxygen requirements. These interactions involve opercular flaring behaviour that is thought to limit aquatic oxygen uptake, and combines with the increase in metabolic rate to cause an increase in air-breathing behaviour. Air-breathing events interrupt display behaviour and increase risk of predation, raising the question of how Siamese fighting fish manage their oxygen requirements during agonistic encounters. Using open-flow respirometry, we measured rate of oxygen consumption in displaying fish to determine if males increase oxygen uptake per breath to minimise visits to the surface, or increase their reliance on aquatic oxygen uptake. We found that the increased oxygen requirements of Siamese fighting fish during display behaviour were met by increased oxygen uptake from the air with no significant changes in aquatic oxygen uptake. The increased aerial oxygen uptake was achieved almost entirely by an increase in air-breathing frequency. We conclude that limitations imposed by the reduced gill surface area of air-breathing fish restrict the ability of Siamese fighting fish to increase aquatic uptake, and limitations of the air-breathing organ of anabantoids largely restrict their capacity to increase oxygen uptake per breath. The resulting need to increase surfacing frequency during metabolically demanding agonistic encounters has presumably contributed to the evolution of the stereotyped surfacing behaviour seen during male-male interactions, during which one of the fish will lead the other to the surface, and each will take a breath of air. Copyright © 2012. Published by Elsevier Inc.

  9. Nose Surgery

    MedlinePlus

    ... because of gravity, causing the sides of the nose to collapse inward, obstructing air flow. Mouth breathing or noisy and restricted breathing are common. Try lifting the tip of your nose to see if you breathe better. If so, ...

  10. Traveling with breathing problems

    MedlinePlus

    ... obstructive lung disease - travel; Chronic bronchitis - travel; Emphysema - travel ... you: Are short of breath most of the time Get short of breath ... doctor if you plan to travel in a place at a high altitude (such ...

  11. Cardiopulmonary Resuscitation (CPR): First Aid

    MedlinePlus

    ... followed by two rescue breaths is considered one cycle. Be careful not to provide too many breaths ... didn't see the child collapse, perform five cycles of compressions and breaths on the child — this ...

  12. Asthma Inhalers: Which One's Right for You?

    MedlinePlus

    ... medication in these inhalers by breathing in a deep, fast breath. There are multiple-dose devices, which ... and convenient to carry. Doesn't require a deep, fast, inhaled breath. Doesn't require a deep, ...

  13. Pulsed quantum cascade laser-based cavity ring-down spectroscopy for ammonia detection in breath.

    PubMed

    Manne, Jagadeeshwari; Sukhorukov, Oleksandr; Jäger, Wolfgang; Tulip, John

    2006-12-20

    Breath analysis can be a valuable, noninvasive tool for the clinical diagnosis of a number of pathological conditions. The detection of ammonia in exhaled breath is of particular interest for it has been linked to kidney malfunction and peptic ulcers. Pulsed cavity ringdown spectroscopy in the mid-IR region has developed into a sensitive analytical technique for trace gas analysis. A gas analyzer based on a pulsed mid-IR quantum cascade laser operating near 970 cm(-1) has been developed for the detection of ammonia levels in breath. We report a sensitivity of approximately 50 parts per billion with a 20 s time resolution for ammonia detection in breath with this system. The challenges and possible solutions for the quantification of ammonia in human breath by the described technique are discussed.

  14. Quiet breathing in hindlimb casted mice.

    PubMed

    Receno, Candace N; Roffo, Katelynn E; Mickey, Marisa C; DeRuisseau, Keith C; DeRuisseau, Lara R

    2018-06-07

    The hindlimb casting model was developed to study skeletal muscle reloading following a period of unloading. It is unknown if ventilation parameters of mice are affected by the casting model. We tested the hypothesis that hindlimb casted mice have similar ventilatory patterns compared to mice with the casts removed. Male CD-1 mice underwent 14 days of hindlimb immobilization via plaster casting. Breathing parameters were obtained utilizing unrestrained barometric plethysmography (UBP). Breathing traces were analyzed with Ponemah software for breathing frequency, tidal volume (TV), and minute ventilation (MV). Frequency, TV and MV did not show any differences in quiet breathing patterns during or post-casting in mice. Thus, the hindlimb casting model does not complicate breathing during and after casting and should not interfere with the unloading and reloading of skeletal muscle. Copyright © 2018 Elsevier B.V. All rights reserved.

  15. Experimental observation of breathing solitons and a third harmonic in a tapered photonic crystal fiber

    NASA Astrophysics Data System (ADS)

    Wang, F.; Yao, C. F.; Li, C. Z.; Jia, Z. X.; Li, Q.; Wu, C. F.; Ohishi, Y.; Qin, W. P.; Qin, G. S.

    2018-02-01

    We report the experimental observation of breathing solitons and a third harmonic in a tapered fluorotellurite photonic crystal fiber (PCF) pumped by a 1560 nm femtosecond fiber laser. The PCF has a core diameter that varies continuously along its length, resulting in a zero-dispersion wavelength that moves from 1325 nm to 906 nm over the transition region. By finely controlling the dispersion map of the tapered PCF and increasing the order of the optical solitons, their breathing behavior is observed in the frequency domain and the number of breaths goes up to 9. Furthermore, the breathing behavior of the optical soliton is transferred to the third harmonic through inter-modal phase-matched processes in the tapered PCF, and the third harmonic also breathes with an increase in the pump power.

  16. Role of atrial receptors in the control of sodium excretion. [pressure breathing and antinatiuretic effects in dogs

    NASA Technical Reports Server (NTRS)

    Meehan, J. R.; Henry, J. P.

    1973-01-01

    Responses of an innervated and a contralateral chronically denervated kidney to mild positive pressure breathing are compared for saline volume expansions in chloralose anesthetized dogs. It is shown that mild pressure breathing significantly reduces sodium excretion, urine flow, free water clearance, and PAH clearance. After 20 minutes of positive pressure breathing, both kidney responses are identical suggesting the release of natriuretic hormone which reduces renal function in addition to the demonstrated change in renal nerve activity. Increase of the left atrial pressure through balloon obstruction of the mitral orifice increases urine flow, sodium excretion and PAH clearance; inflation of the balloon and positive pressure breathing again depresses renal function. Preliminary evidence indicates that receptors in the right atrium are more severely affected by pressure breathing than those in the left atrium.

  17. A novel 13C-urea breath test device for the diagnosis of Helicobacter pylori infection: continuous online measurements allow for faster test results with high accuracy.

    PubMed

    Israeli, Eran; Ilan, Yaron; Meir, Shimon Bar; Buenavida, Claudia; Goldin, Eran

    2003-08-01

    The aim of this study is to determine the accuracy of a novel laptop sized 13C-Urea breath test analyzer that continuously measures expired breath and to use its advantages to decrease testing time. One hundred and eighty-six subjects (mean age of 47.8 years) were tested simultaneously by the BreathID system (Oridion, Israel), and by the traditional IRMS. BreathID continuously measured the expired breath for a ratio of 13CO(2):12CO(2.) This value was expressed as delta over baseline (DOB) and displayed graphically on a screen in real time. One hundred and one subjects were positive and 85 were negative for H. pylori by isotope ratio mass spectrometry (IRMS). The correlation for the BreathID system at 30 minutes was 100% for positive cases and 98% for negative cases. Analysis of the continuous curves generated by the BreathID for all patients permitted definition of different DOB thresholds for a positive or negative result at shorter time intervals. Thus, after 6 minutes a conclusive test result could be obtained for 64% of subjects, and after 10 minutes for 92% of subjects. The 13C-Urea breath test utilizing the technology of molecular correlation spectrometry is an accurate method for determining infection by H. pylori. The advantage of continuous measurements can shorten testing time without compromising accuracy.

  18. Gestation increases the energetic cost of breathing in the lizard Tiliqua rugosa.

    PubMed

    Munns, Suzanne L

    2013-01-15

    High gestational loads result in fetuses that occupy a large proportion of the body cavity and may compress maternal organs. Compression of the lungs results in alterations in breathing patterns during gestation, which may affect the energetic cost of breathing. In this study, the energetic cost of breathing during gestation was determined in the viviparous skink Tiliqua rugosa. Radiographic imaging showed progressive lung compression during gestation and a 30% reduction in the lung inflation index (rib number at which the caudal margin of the lung was imaged divided by total rib number). Pneumotachography and open flow respirometry were used to measure breathing patterns and metabolic rates. Gestation induced a twofold increase in minute ventilation via increases in breathing frequency, but no change in inspired tidal volume. The rates of O(2) consumption and CO(2) production did not change significantly during gestation. Together, these results suggest that a relative hyperventilation occurs during gestation in T. rugosa, which in turn suggests that diffusion and/or perfusion limitations may exist at the lung during gestation. The energetic cost of breathing was estimated as a percentage of resting metabolic rate using hypercapnia to stimulate ventilation at different stages of pregnancy. The energetic cost of breathing in non-pregnant lizards was 19.96±3.85% of resting metabolic rate and increased threefold to 62.80±10.11% during late gestation. This significant increase in the energetic cost of breathing may have significant consequences for energy budgets during gestation.

  19. A Novel Approach to the Identification of Compromised Pulmonary Systems in Smokers by Exploiting Tidal Breathing Patterns.

    PubMed

    Rakshit, Raj; Khasnobish, Anwesha; Chowdhury, Arijit; Sinharay, Arijit; Pal, Arpan; Chakravarty, Tapas

    2018-04-25

    Smoking causes unalterable physiological abnormalities in the pulmonary system. This is emerging as a serious threat worldwide. Unlike spirometry, tidal breathing does not require subjects to undergo forceful breathing maneuvers and is progressing as a new direction towards pulmonary health assessment. The aim of the paper is to evaluate whether tidal breathing signatures can indicate deteriorating adult lung condition in an otherwise healthy person. If successful, such a system can be used as a pre-screening tool for all people before some of them need to undergo a thorough clinical checkup. This work presents a novel systematic approach to identify compromised pulmonary systems in smokers from acquired tidal breathing patterns. Tidal breathing patterns are acquired during restful breathing of adult participants. Thereafter, physiological attributes are extracted from the acquired tidal breathing signals. Finally, a unique classification approach of locally weighted learning with ridge regression (LWL-ridge) is implemented, which handles the subjective variations in tidal breathing data without performing feature normalization. The LWL-ridge classifier recognized compromised pulmonary systems in smokers with an average classification accuracy of 86.17% along with a sensitivity of 80% and a specificity of 92%. The implemented approach outperformed other variants of LWL as well as other standard classifiers and generated comparable results when applied on an external cohort. This end-to-end automated system is suitable for pre-screening people routinely for early detection of lung ailments as a preventive measure in an infrastructure-agnostic way.

  20. Nondispersive infrared spectrometry for 13CO2/12CO2-measurements: a clinically feasible analyzer for stable isotope breath tests in gastroenterology.

    PubMed

    Braden, B; Caspary, W F; Lembcke, B

    1999-06-01

    13C-urea breath tests have become clinical routine for the diagnosis of Helicobacter pylori infection and other isotope breath tests have been invented e.g. for gastric emptying or quantitative liver function testing. Recently, isotope-selective nondispersive infrared spectrometers (NDIRS) have been developed for the analysis of the 13CO2/12CO2-enrichment in breath. In this study, we prospectively tested the validity of a newly developed NDIRS in comparison to isotope ratio mass spectrometry (IRMS). 142 patients with dyspeptic symptoms were tested for Helicobacter pylori infection using the 13C-urea breath test. The isotope ratio analysis of the breath samples was performed in duplicate both using IRMS and NDIRS. The results of the baseline-corrected 13CO2-exhalation values between IRMS and NDIRS were in excellent agreement. The mean difference between both methods was 0.28 +/- 1.93 delta/1000. Evaluating the qualitative urea breath test results in reference to IRMS as the reference the NDIRS had a sensitivity of 97.8% and a specificity of 98.9%. The isotope-selective nondispersive infrared spectroscopy is going to become a reliable, but low-cost and easy-to-operate alternative to expensive isotope ratio mass spectrometry in the analysis of 13C-breath tests.

  1. Piezoresistive Membrane Surface Stress Sensors for Characterization of Breath Samples of Head and Neck Cancer Patients

    PubMed Central

    Lang, Hans Peter; Loizeau, Frédéric; Hiou-Feige, Agnès; Rivals, Jean-Paul; Romero, Pedro; Akiyama, Terunobu; Gerber, Christoph; Meyer, Ernst

    2016-01-01

    For many diseases, where a particular organ is affected, chemical by-products can be found in the patient’s exhaled breath. Breath analysis is often done using gas chromatography and mass spectrometry, but interpretation of results is difficult and time-consuming. We performed characterization of patients’ exhaled breath samples by an electronic nose technique based on an array of nanomechanical membrane sensors. Each membrane is coated with a different thin polymer layer. By pumping the exhaled breath into a measurement chamber, volatile organic compounds present in patients’ breath diffuse into the polymer layers and deform the membranes by changes in surface stress. The bending of the membranes is measured piezoresistively and the signals are converted into voltages. The sensor deflection pattern allows one to characterize the condition of the patient. In a clinical pilot study, we investigated breath samples from head and neck cancer patients and healthy control persons. Evaluation using principal component analysis (PCA) allowed a clear distinction between the two groups. As head and neck cancer can be completely removed by surgery, the breath of cured patients was investigated after surgery again and the results were similar to those of the healthy control group, indicating that surgery was successful. PMID:27455276

  2. Breath acetone to monitor life style interventions in field conditions: an exploratory study.

    PubMed

    Samudrala, Devasena; Lammers, Gerwen; Mandon, Julien; Blanchet, Lionel; Schreuder, Tim H A; Hopman, Maria T; Harren, Frans J M; Tappy, Luc; Cristescu, Simona M

    2014-04-01

    To assess whether breath acetone concentration can be used to monitor the effects of a prolonged physical activity on whole body lipolysis and hepatic ketogenesis in field conditions. Twenty-three non-diabetic, 11 type 1 diabetic, and 17 type 2 diabetic subjects provided breath and blood samples for this study. Samples were collected during the International Four Days Marches, in the Netherlands. For each participant, breath acetone concentration was measured using proton transfer reaction ion trap mass spectrometry, before and after a 30-50 km walk on four consecutive days. Blood non-esterified free fatty acid (NEFA), beta-hydroxybutyrate (BOHB), and glucose concentrations were measured after walking. Breath acetone concentration was significantly higher after than before walking, and was positively correlated with blood NEFA and BOHB concentrations. The effect of walking on breath acetone concentration was repeatedly observed on all four consecutive days. Breath acetone concentrations were higher in type 1 diabetic subjects and lower in type 2 diabetic subjects than in control subjects. Breath acetone can be used to monitor hepatic ketogenesis during walking under field conditions. It may, therefore, provide real-time information on fat burning, which may be of use for monitoring the lifestyle interventions. Copyright © 2014 The Obesity Society.

  3. A taxonomy for mechanical ventilation: 10 fundamental maxims.

    PubMed

    Chatburn, Robert L; El-Khatib, Mohamad; Mireles-Cabodevila, Eduardo

    2014-11-01

    The American Association for Respiratory Care has declared a benchmark for competency in mechanical ventilation that includes the ability to "apply to practice all ventilation modes currently available on all invasive and noninvasive mechanical ventilators." This level of competency presupposes the ability to identify, classify, compare, and contrast all modes of ventilation. Unfortunately, current educational paradigms do not supply the tools to achieve such goals. To fill this gap, we expand and refine a previously described taxonomy for classifying modes of ventilation and explain how it can be understood in terms of 10 fundamental constructs of ventilator technology: (1) defining a breath, (2) defining an assisted breath, (3) specifying the means of assisting breaths based on control variables specified by the equation of motion, (4) classifying breaths in terms of how inspiration is started and stopped, (5) identifying ventilator-initiated versus patient-initiated start and stop events, (6) defining spontaneous and mandatory breaths, (7) defining breath sequences (8), combining control variables and breath sequences into ventilatory patterns, (9) describing targeting schemes, and (10) constructing a formal taxonomy for modes of ventilation composed of control variable, breath sequence, and targeting schemes. Having established the theoretical basis of the taxonomy, we demonstrate a step-by-step procedure to classify any mode on any mechanical ventilator. Copyright © 2014 by Daedalus Enterprises.

  4. Air-breathing adaptation in a marine Devonian lungfish.

    PubMed

    Clement, Alice M; Long, John A

    2010-08-23

    Recent discoveries of tetrapod trackways in 395 Myr old tidal zone deposits of Poland (Niedźwiedzki et al. 2010 Nature 463, 43-48 (doi:10.1038/nature.08623)) indicate that vertebrates had already ventured out of the water and might already have developed some air-breathing capacity by the Middle Devonian. Air-breathing in lungfishes is not considered to be a shared specialization with tetrapods, but evolved independently. Air-breathing in lungfishes has been postulated as starting in Middle Devonian times (ca 385 Ma) in freshwater habitats, based on a set of skeletal characters involved in air-breathing in extant lungfishes. New discoveries described herein of the lungfish Rhinodipterus from marine limestones of Australia identifies the node in dipnoan phylogeny where air-breathing begins, and confirms that lungfishes living in marine habitats had also developed specializations to breathe air by the start of the Late Devonian (ca 375 Ma). While invasion of freshwater habitats from the marine realm was previously suggested to be the prime cause of aerial respiration developing in lungfishes, we believe that global decline in oxygen levels during the Middle Devonian combined with higher metabolic costs is a more likely driver of air-breathing ability, which developed in both marine and freshwater lungfishes and tetrapodomorph fishes such as Gogonasus.

  5. Air-breathing adaptation in a marine Devonian lungfish

    PubMed Central

    Clement, Alice M.; Long, John A.

    2010-01-01

    Recent discoveries of tetrapod trackways in 395 Myr old tidal zone deposits of Poland (Niedźwiedzki et al. 2010 Nature 463, 43–48 (doi:10.1038/nature.08623)) indicate that vertebrates had already ventured out of the water and might already have developed some air-breathing capacity by the Middle Devonian. Air-breathing in lungfishes is not considered to be a shared specialization with tetrapods, but evolved independently. Air-breathing in lungfishes has been postulated as starting in Middle Devonian times (ca 385 Ma) in freshwater habitats, based on a set of skeletal characters involved in air-breathing in extant lungfishes. New discoveries described herein of the lungfish Rhinodipterus from marine limestones of Australia identifies the node in dipnoan phylogeny where air-breathing begins, and confirms that lungfishes living in marine habitats had also developed specializations to breathe air by the start of the Late Devonian (ca 375 Ma). While invasion of freshwater habitats from the marine realm was previously suggested to be the prime cause of aerial respiration developing in lungfishes, we believe that global decline in oxygen levels during the Middle Devonian combined with higher metabolic costs is a more likely driver of air-breathing ability, which developed in both marine and freshwater lungfishes and tetrapodomorph fishes such as Gogonasus. PMID:20147310

  6. Evaluation of Bio-VOC Sampler for Analysis of Volatile Organic Compounds in Exhaled Breath

    PubMed Central

    Kwak, Jae; Fan, Maomian; Harshman, Sean W.; Garrison, Catherine E.; Dershem, Victoria L.; Phillips, Jeffrey B.; Grigsby, Claude C.; Ott, Darrin K.

    2014-01-01

    Monitoring volatile organic compounds (VOCs) from exhaled breath has been used to determine exposures of humans to chemicals. Prior to analysis of VOCs, breath samples are often collected with canisters or bags and concentrated. The Bio-VOC breath sampler, a commercial sampling device, has been recently introduced to the market with growing use. The main advantage for this sampler is to collect the last portion of exhaled breath, which is more likely to represent the air deep in the lungs. However, information about the Bio-VOC sampler is somewhat limited. Therefore, we have thoroughly evaluated the sampler here. We determined the volume of the breath air collected in the sampler was approximately 88 mL. When sampling was repeated multiple times, with the succeeding exhalations applied to a single sorbent tube, we observed linear relationships between the normalized peak intensity and the number of repeated collections with the sampler in many of the breath VOCs detected. No moisture effect was observed on the Tenax sorbent tubes used. However, due to the limitation in the collection volume, the use of the Bio-VOC sampler is recommended only for detection of VOCs present at high concentrations unless repeated collections of breath samples on the sampler are conducted. PMID:25532709

  7. Visualizing Breath using Digital Holography

    NASA Astrophysics Data System (ADS)

    Hobson, P. R.; Reid, I. D.; Wilton, J. B.

    2013-02-01

    Artist Jayne Wilton and physicists Peter Hobson and Ivan Reid of Brunel University are collaborating at Brunel University on a project which aims to use a range of techniques to make visible the normally invisible dynamics of the breath and the verbal and non-verbal communication it facilitates. The breath is a source of a wide range of chemical, auditory and physical exchanges with the direct environment. Digital Holography is being investigated to enable a visually stimulating articulation of the physical trajectory of the breath as it leaves the mouth. Initial findings of this research are presented. Real time digital hologram replay allows the audience to move through holographs of breath-born particles.

  8. The effects of metronome breathing on the variability of autonomic activity measurements.

    PubMed

    Driscoll, D; Dicicco, G

    2000-01-01

    Many chiropractors hypothesize that spinal manipulation affects the autonomic nervous system (ANS). However, the ANS responses to chiropractic manipulative therapy are not well documented, and more research is needed to support this hypothesis. This study represents a step toward the development of a reliable method by which to document that chiropractic manipulative therapy does affect the ANS by exploring the use of paced breathing as a way to reduce the inherent variability in ANS measurements. To examine the hypothesis that the variability of ANS measurements would be reduced if breathing were paced to a metronome at 12 breaths/min. The study was performed at Parker College Research Institute. Eight normotensive subjects were recruited from the student body and staff. Respiration frequency was measured through a strain gauge. A 3-lead electrocardiogram (ECG) was used to register the electric activity of the heart, and arterial tonometry monitors were used to record the left and right radial artery blood pressures. Signals were recorded on an IBM-compatible computer with a sampling frequency of 100 Hz. Normal breathing was used for the first 3 recordings, and breathing was paced to a metronome for the final 3 recordings at 12 breaths/min. Fourier analysis was performed on the beat-by-beat fluctuations of the ECG-determined R-R interval and systolic arterial pressure (SBP). Low-frequency fluctuations (LF; 0.04-0.15 Hz) reflected sympathetic activity, whereas high-frequency fluctuations (HF; 0.15-0.4 Hz) represented parasympathetic activity. Sympathovagal indices were determined from the ratio of the two bandwidths (LF/HF). The coefficient of variation (CV%) for autonomic parameters was calculated ([average/SD] x 100%) to compare breathing normally and breathing to a metronome with respect to variability. One-way analysis of variance was used to detect differences. A value of P < 0.05 was considered statistically significant; all results are presented as average +/- SD. Three male and 5 female normotensive subjects were studied. Metronome breathing did not produce any significant changes in blood pressure for the left and right radial arteries, heart rate, or pressure pulse transmission time. Breathing to a metronome increased ECG-HF power (0.25 +/- 0.07 vs 0.35 +/- 0.09, P < 0.04), decreased ECG-LF/HF (1.08 +/- 0.55 vs 0.57 +/- 0.35, P < 0.05), and reduced the CV% for ECG-LF (47.6% +/- 23.4% vs 23.8% +/- 14.6%, P < 0.03), ECG-HF (46.2% +/- 14.2% vs 25.8% +/- 17.0%, P < 0.03) and ECG-LF/HF (50.1% +/- 27.6% vs 23.4% +/- 12.3%, P < 0.03) in comparison with normal breathing. Metronome breathing increased the left and right radial artery SBP-HF fluctuations (left, 0.11 +/- 0.05 vs 0.30 +/- 0.16, P < 0.007; right, 0.09 +/- 0.05 vs 0.27 +/- 0.15, P < 0.008) and decreased the SBP-LF/HF components (left, 3.42 +/- 2.36 vs 1.14 +/- 0.88, P > 0.03; right, 3.08 +/- 1.77 vs 1.20 +/- 0.93, P < 0.02). Metronome breathing did not significantly alter the CV% for SBP-HF, SBP-LF, and SBP-LF/HF. Metronome breathing increased parasympathetic activity, as evidenced by augmented HF power in the ECG and SBP data. The variability (CV%) of ECG-determined ANS measurements was significantly reduced with paced breathing at 12 breaths/min, but no significant reductions were observed for the SBP-determined ANS measurements. These findings indicate that ECG data are more sensitive than SBP data for future clinical trials.

  9. Diagnostic Chemical Analysis of Exhaled Human Breath Using a Novel Sub-Millimeter Spectroscopic Approach

    NASA Astrophysics Data System (ADS)

    Fosnight, Alyssa M.; Moran, Benjamin L.; Branco, Daniela R.; Thomas, Jessica R.; Medvedev, Ivan R.

    2013-06-01

    As many as 3000 chemicals are reported to be found in exhaled human breath. Many of these chemicals are linked to certain health conditions and environmental exposures. Present state of the art techniques used for analysis of exhaled human breath include mass spectrometry based methods, infrared spectroscopic sensors, electro chemical sensors and semiconductor oxide based testers. Some of these techniques are commercially available but are somewhat limited in their specificity and exhibit fairly high probability of false alarm. Here, we present the results of our most recent study which demonstrated a novel application of a terahertz high resolutions spectroscopic technique to the analysis of exhaled human breath, focused on detection of ethanol in the exhaled breath of a person which consumed an alcoholic drink. This technique possesses nearly ``absolute'' specificity and we demonstrated its ability to uniquely identify ethanol, methanol, and acetone in human breath. This project is now complete and we are looking to extend this method of chemical analysis of exhaled human breath to a broader range of chemicals in an attempt to demonstrate its potential for biomedical diagnostic purposes.

  10. Fecal /sup 13/C analysis for the detection and quantitation of intestinal malabsorption

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Klein, P.D.; MacLean, W.C. Jr.; Watkins, J.B.

    Use of /sup 14/CO/sub 2/ breath tests and fecal analyses for the detection and quantitation of intestinal malabsorption has been extensively documented in adult subjects. The use of radioisotopes has extended the range of breath test applications to include pediatric and geriatric subjects. Here we report a fecal /sup 13/C analysis that can be used in conjunction with /sup 14/CO/sub 2/ breath tests. Twenty-four-hour fecal samples were collected before and after the administration of a labeled substrate. Simultaneous cholyglycine /sup 13/CO/sub 2/ breath tests and fecal assays were performed in five children. One child with bacterial overgrowth had an abnormalmore » breath test and a normal fecal test. Of three children with ileal dysfunction, only one had an abnormal breath test, whereas the fecal test was abnormal in all three. Both the breath test and fecal test were abnormal for a child who had undergone an ileal resection. Both tests were normal for a child with ulcerative colitis.« less

  11. A novel CT acquisition and analysis technique for breathing motion modeling

    NASA Astrophysics Data System (ADS)

    Low, Daniel A.; White, Benjamin M.; Lee, Percy P.; Thomas, David H.; Gaudio, Sergio; Jani, Shyam S.; Wu, Xiao; Lamb, James M.

    2013-06-01

    To report on a novel technique for providing artifact-free quantitative four-dimensional computed tomography (4DCT) image datasets for breathing motion modeling. Commercial clinical 4DCT methods have difficulty managing irregular breathing. The resulting images contain motion-induced artifacts that can distort structures and inaccurately characterize breathing motion. We have developed a novel scanning and analysis method for motion-correlated CT that utilizes standard repeated fast helical acquisitions, a simultaneous breathing surrogate measurement, deformable image registration, and a published breathing motion model. The motion model differs from the CT-measured motion by an average of 0.65 mm, indicating the precision of the motion model. The integral of the divergence of one of the motion model parameters is predicted to be a constant 1.11 and is found in this case to be 1.09, indicating the accuracy of the motion model. The proposed technique shows promise for providing motion-artifact free images at user-selected breathing phases, accurate Hounsfield units, and noise characteristics similar to non-4D CT techniques, at a patient dose similar to or less than current 4DCT techniques.

  12. The likelihood of acetone interference in breath alcohol measurement

    DOT National Transportation Integrated Search

    1985-09-01

    This report discusses the significance of possible interference of acetone in breath alcohol testing. The following dimensions were considered: 1) what levels of acetone concentration may appear on the breath; 2) what levels of acetone concentration ...

  13. 49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...

  14. 49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...

  15. 49 CFR 40.267 - What problems always cause an alcohol test to be cancelled?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... breath tube ASD). (4) The breath tube ASD is tested with an analyzer which has not been pre-calibrated... the case of a screening test conducted on a saliva ASD or a breath tube ASD: (1) The STT or BAT reads... § 40.245(a)(8) for the saliva ASD and § 40.245(b)(8) for the breath tube ASD). (2) The saliva ASD does...

  16. 49 CFR 40.245 - What is the procedure for an alcohol screening test using a saliva ASD or a breath tube ASD?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... a breath tube ASD? (a) As the STT or BAT, you must take the following steps when using the saliva... ATF. (b) As the STT or BAT, you must take the following steps when using the breath tube ASD: (1... the manufacturer's directions. (11) You must note the fact that you used a breath tube device in Step...

  17. Dynamic model inversion techniques for breath-by-breath measurement of carbon dioxide from low bandwidth sensors.

    PubMed

    Sivaramakrishnan, Shyam; Rajamani, Rajesh; Johnson, Bruce D

    2009-01-01

    Respiratory CO(2) measurement (capnography) is an important diagnosis tool that lacks inexpensive and wearable sensors. This paper develops techniques to enable use of inexpensive but slow CO(2) sensors for breath-by-breath tracking of CO(2) concentration. This is achieved by mathematically modeling the dynamic response and using model-inversion techniques to predict input CO(2) concentration from the slow-varying output. Experiments are designed to identify model-dynamics and extract relevant model-parameters for a solidstate room monitoring CO(2) sensor. A second-order model that accounts for flow through the sensor's filter and casing is found to be accurate in describing the sensor's slow response. The resulting estimate is compared with a standard-of-care respiratory CO(2) analyzer and shown to effectively track variation in breath-by-breath CO(2) concentration. This methodology is potentially useful for measuring fast-varying inputs to any slow sensor.

  18. Spike-Timing of Orbitofrontal Neurons Is Synchronized With Breathing.

    PubMed

    Kőszeghy, Áron; Lasztóczi, Bálint; Forro, Thomas; Klausberger, Thomas

    2018-01-01

    The orbitofrontal cortex (OFC) has been implicated in a multiplicity of complex brain functions, including representations of expected outcome properties, post-decision confidence, momentary food-reward values, complex flavors and odors. As breathing rhythm has an influence on odor processing at primary olfactory areas, we tested the hypothesis that it may also influence neuronal activity in the OFC, a prefrontal area involved also in higher order processing of odors. We recorded spike timing of orbitofrontal neurons as well as local field potentials (LFPs) in awake, head-fixed mice, together with the breathing rhythm. We observed that a large majority of orbitofrontal neurons showed robust phase-coupling to breathing during immobility and running. The phase coupling of action potentials to breathing was significantly stronger in orbitofrontal neurons compared to cells in the medial prefrontal cortex. The characteristic synchronization of orbitofrontal neurons with breathing might provide a temporal framework for multi-variable processing of olfactory, gustatory and reward-value relationships.

  19. The effects of Pilates breathing trainings on trunk muscle activation in healthy female subjects: a prospective study

    PubMed Central

    Kim, Sung-Tae; Lee, Joon-Hee

    2017-01-01

    [Purpose] To investigate the effects of Pilates breathing on trunk muscle activation. [Subjects and Methods] Twenty-eight healthy female adults were selected for this study. Participants’ trunk muscle activations were measured while they performed curl-ups, chest-head lifts, and lifting tasks. Pilates breathing trainings were performed for 60 minutes per each session, 3 times per week for 2 weeks. Post-training muscle activations were measured by the same methods used for the pre-training muscle activations. [Results] All trunk muscles measured in this study had increased activities after Pilates breathing trainings. All activities of the transversus abdominis/internal abdominal oblique, and multifidus significantly increased. [Conclusion] Pilates breathing increased activities of the trunk stabilizer muscles. Activation of the trunk muscle indicates that practicing Pilates breathing while performing lifting tasks will reduce the risk of trunk injuries. PMID:28265138

  20. Detection of creatinine in exhaled breath of humans with chronic kidney disease by extractive electrospray ionization mass spectrometry.

    PubMed

    Zeng, Qian; Li, Penghui; Cai, Yunfeng; Zhou, Wei; Wang, Haidong; Luo, Jiao; Ding, Jianhua; Chen, Huanwen

    2016-02-09

    Exhaled breath contains chemicals that have a diagnostic value in human pathologies. Here in vivo breath analysis of creatinine has been demonstrated by constructing a novel platform based on extractive electrospray ionization mass spectrometry (EESI-MS) without sample pretreatment. Under optimized experimental conditions, the limit of creatinine detection in breath was 30.57 ng L(-1), and the linear range of detection was from 0.3 μg L(-1) to 100 μg L(-1). The concentration range of creatinine in the exhaled breath of 50 volunteers with chronic kidney disease was from 42 pptv to 924 pptv, and the range of the relative standard deviations was from 9.3% to 19.2%. The method provides high sensitivity, high specificity and high speed for semi-quantitative analysis of creatinine in exhaled human breath.

  1. Chemically Polymerized Polypyrrole for On-Chip Concentration of Volatile Breath Metabolites

    PubMed Central

    Strand, Nicholas; Bhushan, Abhinav; Schivo, Michael; Kenyon, Nicholas J.; Davis, Cristina E.

    2009-01-01

    A wide range of metabolites are measured in the gas phase of exhaled human breath, and some of these biomarkers are frequently observed to be up- or down-regulated in certain disease states. Portable breath analysis systems have the potential for a wide range of applications in health diagnostics. However, this is currently limited by the lack of concentration mechanisms to enhance trace metabolites found in the breath to levels that can be adequately recorded using miniaturized gas-phase sensors. In this study we have created chip-based polymeric pre-concentration devices capable of absorbing and desorbing breath volatiles for subsequent chemical analysis. These devices appear to concentrate chemicals from both environmental air samples as well as directly from exhaled human breath, and these devices may have applications in lab-on-a-chip-based environmental and health monitoring systems. PMID:20161533

  2. The effects of Pilates breathing trainings on trunk muscle activation in healthy female subjects: a prospective study.

    PubMed

    Kim, Sung-Tae; Lee, Joon-Hee

    2017-02-01

    [Purpose] To investigate the effects of Pilates breathing on trunk muscle activation. [Subjects and Methods] Twenty-eight healthy female adults were selected for this study. Participants' trunk muscle activations were measured while they performed curl-ups, chest-head lifts, and lifting tasks. Pilates breathing trainings were performed for 60 minutes per each session, 3 times per week for 2 weeks. Post-training muscle activations were measured by the same methods used for the pre-training muscle activations. [Results] All trunk muscles measured in this study had increased activities after Pilates breathing trainings. All activities of the transversus abdominis/internal abdominal oblique, and multifidus significantly increased. [Conclusion] Pilates breathing increased activities of the trunk stabilizer muscles. Activation of the trunk muscle indicates that practicing Pilates breathing while performing lifting tasks will reduce the risk of trunk injuries.

  3. Effects of deep breathing on internal oblique and multifidus muscle activity in three sitting postures

    PubMed Central

    Ko, Min-Joo; Jung, Eun-Joo; Kim, Moon-Hwan; Oh, Jae-Seop

    2018-01-01

    [Purpose] This study was to investigate differences in the level of activity of the external oblique (EO), internal oblique (IO), and multifidus (MF) muscles with deep breathing in three sitting postures. [Subjects and Methods] Sixteen healthy women were recruited. The muscle activity (EO, IO, MF) of all subjects was measured in three sitting postures (slumped, thoracic upright, and lumbo-pelvic upright sitting postures) using surface electromyography. The activity of the same muscles was then remeasured in the three sitting postures during deep breathing. [Results] Deep breathing significantly increased activity in the EO, IO, and MF compared with normal breathing. Comparing postures, the activity of the MF and IO muscles was highest in the lumbo-pelvic upright sitting posture. [Conclusion] An lumbo-pelvic upright sitting posture with deep breathing could increase IO and MF muscle activity, thus improving lumbo-pelvic region stability. PMID:29706695

  4. Quantification of the thorax-to-abdomen breathing ratio for breathing motion modeling.

    PubMed

    White, Benjamin M; Zhao, Tianyu; Lamb, James; Bradley, Jeffrey D; Low, Daniel A

    2013-06-01

    The purpose of this study was to develop a methodology to quantitatively measure the thorax-to-abdomen breathing ratio from a 4DCT dataset for breathing motion modeling and breathing motion studies. The thorax-to-abdomen breathing ratio was quantified by measuring the rate of cross-sectional volume increase throughout the thorax and abdomen as a function of tidal volume. Twenty-six 16-slice 4DCT patient datasets were acquired during quiet respiration using a protocol that acquired 25 ciné scans at each couch position. Fifteen datasets included data from the neck through the pelvis. Tidal volume, measured using a spirometer and abdominal pneumatic bellows, was used as breathing-cycle surrogates. The cross-sectional volume encompassed by the skin contour when compared for each CT slice against the tidal volume exhibited a nearly linear relationship. A robust iteratively reweighted least squares regression analysis was used to determine η(i), defined as the amount of cross-sectional volume expansion at each slice i per unit tidal volume. The sum Ση(i) throughout all slices was predicted to be the ratio of the geometric expansion of the lung and the tidal volume; 1.11. The Xiphoid process was selected as the boundary between the thorax and abdomen. The Xiphoid process slice was identified in a scan acquired at mid-inhalation. The imaging protocol had not originally been designed for purposes of measuring the thorax-to-abdomen breathing ratio so the scans did not extend to the anatomy with η(i) = 0. Extrapolation of η(i)-η(i) = 0 was used to include the entire breathing volume. The thorax and abdomen regions were individually analyzed to determine the thorax-to-abdomen breathing ratios. There were 11 image datasets that had been scanned only through the thorax. For these cases, the abdomen breathing component was equal to 1.11 - Ση(i) where the sum was taken throughout the thorax. The average Ση(i) for thorax and abdomen image datasets was found to be 1.20 ± 0.17, close to the expected value of 1.11. The thorax-to-abdomen breathing ratio was 0.32 ± 0.24. The average Ση(i) was 0.26 ± 0.14 in the thorax and 0.93 ± 0.22 in the abdomen. In the scan datasets that encompassed only the thorax, the average Ση(i) was 0.21 ± 0.11. A method to quantify the relationship between abdomen and thoracic breathing was developed and characterized.

  5. The impact of dual-source parallel radiofrequency transmission with patient-adaptive shimming on the cardiac magnetic resonance in children at 3.0 T.

    PubMed

    Wang, Haipeng; Qiu, Liyun; Wang, Guangbin; Gao, Fei; Jia, Haipeng; Zhao, Junyu; Chen, Weibo; Wang, Cuiyan; Zhao, Bin

    2017-06-01

    The cardiac magnetic resonance (CMR) of children at 3.0 T presents a unique set of technical challenges because of their small cardiac anatomical structures, fast heart rates, and the limited ability to keep motionless and hold breathe, which could cause problems associated with field inhomogeneity and degrade the image quality. The aim of our study was to evaluate the effect of dual-source parallel radiofrequency (RF) transmission on the B1 homogeneity and image quality in children with CMR at 3.0 T. The study was approved by the institutional ethics committee and written informed consent was obtained. A total of 30 free-breathing children and 30 breath-hold children performed CMR examinations with dual-source and single-source RF transmission. The B1 homogeneity, contrast ratio (CR) of cine images, and off-resonance artifacts in cine images between dual-source and single-source RF transmission were assessed in free-breathing and breath-hold groups, respectively. In both free-breathing and breath-hold groups, higher mean percentage of flip angle (free-breathing group: 104.2 ± 4.6 vs 95.5 ± 6.3, P < .001; breath-hold group: 101.5 ± 5.1 vs 92.5 ± 6.3, P < .001) and lower coefficient of variation (free-breathing group: 0.06 ± 0.02 vs 0.09 ± 0.03, P < .001; breath-hold group: 0.07 ± 0.03 vs 0.10 ± 0.04, P = .005) were found with dual-source than with single-source RF transmission. Both the CRs in the horizontal long axis (HLA) and short axis of cine images with dual-source RF transmission was improved (P < .05 for all). The scores of off-resonance artifacts in the HLA with dual-source RF transmission were higher in both free-breathing and breath-hold groups (P < .05 for all), with substantial interreader agreement (kappa values from 0.68 to 0.74). Compared with conventional single-source, dual-source parallel RF transmission could significantly improve the B1 homogeneity and image quality for CMR in children at 3.0 T. This technology could be taken into account in CMR for children with cardiac diseases.

  6. Can simple mobile phone applications provide reliable counts of respiratory rates in sick infants and children? An initial evaluation of three new applications.

    PubMed

    Black, James; Gerdtz, Marie; Nicholson, Pat; Crellin, Dianne; Browning, Laura; Simpson, Julie; Bell, Lauren; Santamaria, Nick

    2015-05-01

    Respiratory rate is an important sign that is commonly either not recorded or recorded incorrectly. Mobile phone ownership is increasing even in resource-poor settings. Phone applications may improve the accuracy and ease of counting of respiratory rates. The study assessed the reliability and initial users' impressions of four mobile phone respiratory timer approaches, compared to a 60-second count by the same participants. Three mobile applications (applying four different counting approaches plus a standard 60-second count) were created using the Java Mobile Edition and tested on Nokia C1-01 phones. Apart from the 60-second timer application, the others included a counter based on the time for ten breaths, and three based on the time interval between breaths ('Once-per-Breath', in which the user presses for each breath and the application calculates the rate after 10 or 20 breaths, or after 60s). Nursing and physiotherapy students used the applications to count respiratory rates in a set of brief video recordings of children with different respiratory illnesses. Limits of agreement (compared to the same participant's standard 60-second count), intra-class correlation coefficients and standard errors of measurement were calculated to compare the reliability of the four approaches, and a usability questionnaire was completed by the participants. There was considerable variation in the counts, with large components of the variation related to the participants and the videos, as well as the methods. None of the methods was entirely reliable, with no limits of agreement better than -10 to +9 breaths/min. Some of the methods were superior to the others, with ICCs from 0.24 to 0.92. By ICC the Once-per-Breath 60-second count and the Once-per-Breath 20-breath count were the most consistent, better even than the 60-second count by the participants. The 10-breath approaches performed least well. Users' initial impressions were positive, with little difference between the applications found. This study provides evidence that applications running on simple phones can be used to count respiratory rates in children. The Once-per-Breath methods are the most reliable, outperforming the 60-second count. For children with raised respiratory rates the 20-breath version of the Once-per-Breath method is faster, so it is a more suitable option where health workers are under time pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  7. Robust optimization methods for cardiac sparing in tangential breast IMRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahmoudzadeh, Houra, E-mail: houra@mie.utoronto.ca; Lee, Jenny; Chan, Timothy C. Y.

    Purpose: In left-sided tangential breast intensity modulated radiation therapy (IMRT), the heart may enter the radiation field and receive excessive radiation while the patient is breathing. The patient’s breathing pattern is often irregular and unpredictable. We verify the clinical applicability of a heart-sparing robust optimization approach for breast IMRT. We compare robust optimized plans with clinical plans at free-breathing and clinical plans at deep inspiration breath-hold (DIBH) using active breathing control (ABC). Methods: Eight patients were included in the study with each patient simulated using 4D-CT. The 4D-CT image acquisition generated ten breathing phase datasets. An average scan was constructedmore » using all the phase datasets. Two of the eight patients were also imaged at breath-hold using ABC. The 4D-CT datasets were used to calculate the accumulated dose for robust optimized and clinical plans based on deformable registration. We generated a set of simulated breathing probability mass functions, which represent the fraction of time patients spend in different breathing phases. The robust optimization method was applied to each patient using a set of dose-influence matrices extracted from the 4D-CT data and a model of the breathing motion uncertainty. The goal of the optimization models was to minimize the dose to the heart while ensuring dose constraints on the target were achieved under breathing motion uncertainty. Results: Robust optimized plans were improved or equivalent to the clinical plans in terms of heart sparing for all patients studied. The robust method reduced the accumulated heart dose (D10cc) by up to 801 cGy compared to the clinical method while also improving the coverage of the accumulated whole breast target volume. On average, the robust method reduced the heart dose (D10cc) by 364 cGy and improved the optBreast dose (D99%) by 477 cGy. In addition, the robust method had smaller deviations from the planned dose to the accumulated dose. The deviation of the accumulated dose from the planned dose for the optBreast (D99%) was 12 cGy for robust versus 445 cGy for clinical. The deviation for the heart (D10cc) was 41 cGy for robust and 320 cGy for clinical. Conclusions: The robust optimization approach can reduce heart dose compared to the clinical method at free-breathing and can potentially reduce the need for breath-hold techniques.« less

  8. Mechanisms linking metabolism of Helicobacter pylori to 18O and 13C-isotopes of human breath CO2

    PubMed Central

    Som, Suman; De, Anulekha; Banik, Gourab Dutta; Maity, Abhijit; Ghosh, Chiranjit; Pal, Mithun; Daschakraborty, Sunil B.; Chaudhuri, Sujit; Jana, Subhra; Pradhan, Manik

    2015-01-01

    The gastric pathogen Helicobacter pylori utilize glucose during metabolism, but the underlying mechanisms linking to oxygen-18 (18O) and carbon-13 (13C)-isotopic fractionations of breath CO2 during glucose metabolism are poorly understood. Using the excretion dynamics of 18O/16O and 13C/12C-isotope ratios of breath CO2, we found that individuals with Helicobacter pylori infections exhibited significantly higher isotopic enrichments of 18O in breath CO2 during the 2h-glucose metabolism regardless of the isotopic nature of the substrate, while no significant enrichments of 18O in breath CO2 were manifested in individuals without the infections. In contrast, the 13C-isotopic enrichments of breath CO2 were significantly higher in individuals with Helicobacter pylori compared to individuals without infections in response to 13C-enriched glucose uptake, whereas a distinguishable change of breath 13C/12C-isotope ratios was also evident when Helicobacter pylori utilize natural glucose. Moreover, monitoring the 18O and 13C-isotopic exchange in breath CO2 successfully diagnosed the eradications of Helicobacter pylori infections following a standard therapy. Our findings suggest that breath 12C18O16O and 13C16O16O can be used as potential molecular biomarkers to distinctively track the pathogenesis of Helicobacter pylori and also for eradication purposes and thus may open new perspectives into the pathogen’s physiology along with isotope-specific non-invasive diagnosis of the infection. PMID:26039789

  9. Short-Term Intra-Subject Variation in Exhaled Volatile Organic Compounds (VOCs) in COPD Patients and Healthy Controls and Its Effect on Disease Classification

    PubMed Central

    Phillips, Christopher; Mac Parthaláin, Neil; Syed, Yasir; Deganello, Davide; Claypole, Timothy; Lewis, Keir

    2014-01-01

    Exhaled volatile organic compounds (VOCs) are of interest for their potential to diagnose disease non-invasively. However, most breath VOC studies have analyzed single breath samples from an individual and assumed them to be wholly consistent representative of the person. This provided the motivation for an investigation of the variability of breath profiles when three breath samples are taken over a short time period (two minute intervals between samples) for 118 stable patients with Chronic Obstructive Pulmonary Disease (COPD) and 63 healthy controls and analyzed by gas chromatography and mass spectroscopy (GC/MS). The extent of the variation in VOC levels differed between COPD and healthy subjects and the patterns of variation differed for isoprene versus the bulk of other VOCs. In addition, machine learning approaches were applied to the breath data to establish whether these samples differed in their ability to discriminate COPD from healthy states and whether aggregation of multiple samples, into single data sets, could offer improved discrimination. The three breath samples gave similar classification accuracy to one another when evaluated separately (66.5% to 68.3% subjects classified correctly depending on the breath repetition used). Combining multiple breath samples into single data sets gave better discrimination (73.4% subjects classified correctly). Although accuracy is not sufficient for COPD diagnosis in a clinical setting, enhanced sampling and analysis may improve accuracy further. Variability in samples, and short-term effects of practice or exertion, need to be considered in any breath testing program to improve reliability and optimize discrimination. PMID:24957028

  10. Short-Term Intra-Subject Variation in Exhaled Volatile Organic Compounds (VOCs) in COPD Patients and Healthy Controls and Its Effect on Disease Classification.

    PubMed

    Phillips, Christopher; Mac Parthaláin, Neil; Syed, Yasir; Deganello, Davide; Claypole, Timothy; Lewis, Keir

    2014-05-09

    Exhaled volatile organic compounds (VOCs) are of interest for their potential to diagnose disease non-invasively. However, most breath VOC studies have analyzed single breath samples from an individual and assumed them to be wholly consistent representative of the person. This provided the motivation for an investigation of the variability of breath profiles when three breath samples are taken over a short time period (two minute intervals between samples) for 118 stable patients with Chronic Obstructive Pulmonary Disease (COPD) and 63 healthy controls and analyzed by gas chromatography and mass spectroscopy (GC/MS). The extent of the variation in VOC levels differed between COPD and healthy subjects and the patterns of variation differed for isoprene versus the bulk of other VOCs. In addition, machine learning approaches were applied to the breath data to establish whether these samples differed in their ability to discriminate COPD from healthy states and whether aggregation of multiple samples, into single data sets, could offer improved discrimination. The three breath samples gave similar classification accuracy to one another when evaluated separately (66.5% to 68.3% subjects classified correctly depending on the breath repetition used). Combining multiple breath samples into single data sets gave better discrimination (73.4% subjects classified correctly). Although accuracy is not sufficient for COPD diagnosis in a clinical setting, enhanced sampling and analysis may improve accuracy further. Variability in samples, and short-term effects of practice or exertion, need to be considered in any breath testing program to improve reliability and optimize discrimination.

  11. Optimization of single shot 3D breath-hold non-enhanced MR angiography of the renal arteries.

    PubMed

    Tan, Huan; Koktzoglou, Ioannis; Glielmi, Christopher; Galizia, Mauricio; Edelman, Robert R

    2012-05-19

    Cardiac and navigator-gated, inversion-prepared non-enhanced magnetic resonance angiography techniques can accurately depict the renal arteries without the need for contrast administration. However, the scan time and effectiveness of navigator-gated techniques depend on the subject respiratory pattern, which at times results in excessively prolonged scan times or suboptimal image quality. A single-shot 3D magnetization-prepared steady-state free precession technique was implemented to allow the full extent of the renal arteries to be depicted within a single breath-hold. Technical optimization of the breath-hold technique was performed with fourteen healthy volunteers. An alternative magnetization preparation scheme was tested to maximize inflow signal. Quantitative and qualitative comparisons were made between the breath-hold technique and the clinically accepted navigator-gated technique in both volunteers and patients on a 1.5 T scanner. The breath-hold technique provided an average of seven fold reduction in imaging time, without significant loss of image quality. Comparable single-to-noise and contrast-to-noise ratios of intra- and extra-renal arteries were found between the breath-hold and the navigator-gated techniques in volunteers. Furthermore, the breath-hold technique demonstrated good image quality for diagnostic purposes in a small number of patients in a pilot study. The single-shot, breath-hold technique offers an alternative to navigator-gated methods for non-enhanced renal magnetic resonance angiography. The initial results suggest a potential supplementary clinical role for the breath-hold technique in the evaluation of suspected renal artery diseases.

  12. Usefulness of Guided Breathing for Dose Rate-Regulated Tracking

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han-Oh, Sarah; Department of Radiation Oncology, University of Maryland Medical System, Baltimore, MD; Yi, Byong Yong

    2009-02-01

    Purpose: To evaluate the usefulness of guided breathing for dose rate-regulated tracking (DRRT), a new technique to compensate for intrafraction tumor motion. Methods and Materials: DRRT uses a preprogrammed multileaf collimator sequence that tracks the tumor motion derived from four-dimensional computed tomography and the corresponding breathing signals measured before treatment. Because the multileaf collimator speed can be controlled by adjusting the dose rate, the multileaf collimator positions are adjusted in real time during treatment by dose rate regulation, thereby maintaining synchrony with the tumor motion. DRRT treatment was simulated with free, audio-guided, and audiovisual-guided breathing signals acquired from 23 lungmore » cancer patients. The tracking error and duty cycle for each patient were determined as a function of the system time delay (range, 0-1.0 s). Results: The tracking error and duty cycle averaged for all 23 patients was 1.9 {+-} 0.8 mm and 92% {+-} 5%, 1.9 {+-} 1.0 mm and 93% {+-} 6%, and 1.8 {+-} 0.7 mm and 92% {+-} 6% for the free, audio-guided, and audiovisual-guided breathing, respectively, for a time delay of 0.35 s. The small differences in both the tracking error and the duty cycle with guided breathing were not statistically significant. Conclusion: DRRT by its nature adapts well to variations in breathing frequency, which is also the motivation for guided-breathing techniques. Because of this redundancy, guided breathing does not result in significant improvements for either the tracking error or the duty cycle when DRRT is used for real-time tumor tracking.« less

  13. Breath Analysis Using Laser Spectroscopic Techniques: Breath Biomarkers, Spectral Fingerprints, and Detection Limits

    PubMed Central

    Wang, Chuji; Sahay, Peeyush

    2009-01-01

    Breath analysis, a promising new field of medicine and medical instrumentation, potentially offers noninvasive, real-time, and point-of-care (POC) disease diagnostics and metabolic status monitoring. Numerous breath biomarkers have been detected and quantified so far by using the GC-MS technique. Recent advances in laser spectroscopic techniques and laser sources have driven breath analysis to new heights, moving from laboratory research to commercial reality. Laser spectroscopic detection techniques not only have high-sensitivity and high-selectivity, as equivalently offered by the MS-based techniques, but also have the advantageous features of near real-time response, low instrument costs, and POC function. Of the approximately 35 established breath biomarkers, such as acetone, ammonia, carbon dioxide, ethane, methane, and nitric oxide, 14 species in exhaled human breath have been analyzed by high-sensitivity laser spectroscopic techniques, namely, tunable diode laser absorption spectroscopy (TDLAS), cavity ringdown spectroscopy (CRDS), integrated cavity output spectroscopy (ICOS), cavity enhanced absorption spectroscopy (CEAS), cavity leak-out spectroscopy (CALOS), photoacoustic spectroscopy (PAS), quartz-enhanced photoacoustic spectroscopy (QEPAS), and optical frequency comb cavity-enhanced absorption spectroscopy (OFC-CEAS). Spectral fingerprints of the measured biomarkers span from the UV to the mid-IR spectral regions and the detection limits achieved by the laser techniques range from parts per million to parts per billion levels. Sensors using the laser spectroscopic techniques for a few breath biomarkers, e.g., carbon dioxide, nitric oxide, etc. are commercially available. This review presents an update on the latest developments in laser-based breath analysis. PMID:22408503

  14. Δ(9)-Tetrahydrocannabinol concentrations in exhaled breath and physiological effects following cannabis intake - A pilot study using illicit cannabis.

    PubMed

    Coucke, Line; Massarini, Enrico; Ostijn, Zachery; Beck, Olof; Verstraete, Alain G

    2016-09-01

    Δ(9)-Tetrahydrocannabinol (THC) can be measured in exhaled breath by using an aerosol particle collection device. The sampling procedure is simple, non-invasive and takes only 2-3min. In the present study we measured the amount of THC in exhaled breath of cannabis users at specific time intervals up to 3h after smoking one cannabis cigarette. The breath concentration-effect relationship was studied by measuring the pulse rate and the pupil diameter to assess physiological changes. THC and the main metabolite 11-nor-9-carboxy-Δ(9)-tetrahydrocannabinol were analyzed in exhaled breath by a liquid chromatography-tandem mass spectrometry method. Thirteen subjects (9 males and 4 females, aged 23-24years) participated. Five of those were using cannabis more frequently than monthly. THC was detected in most subjects already at baseline, concentrations increased following smoking and remained detectable for over 3h (mean THC concentration in breath at 3h: 1479pg/sample). Pulse rate (p=0.015) and pupil diameter (p=0.044) were significantly altered up to 30min after smoking. The detection window of cannabis in breath after smoking one cannabis cigarette in occasional and chronic smokers was at least 3h. Only THC was detected, and not the metabolite. The THC concentration in exhaled breath was related to the physiological changes that occur over time. Exhaled breath can be used to detect recent cannabis exposure. Copyright © 2016 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  15. Variations in respiratory excretion of carbon dioxide can be used to calculate pulmonary blood flow.

    PubMed

    Preiss, David A; Azami, Takafumi; Urman, Richard D

    2015-02-01

    A non-invasive means of measuring pulmonary blood flow (PBF) would have numerous benefits in medicine. Traditionally, respiratory-based methods require breathing maneuvers, partial rebreathing, or foreign gas mixing because exhaled CO2 volume on a per-breath basis does not accurately represent alveolar exchange of CO2. We hypothesized that if the dilutional effect of the functional residual capacity was accounted for, the relationship between the calculated volume of CO2 removed per breath and the alveolar partial pressure of CO2 would be reversely linear. A computer model was developed that uses variable tidal breathing to calculate CO2 removal per breath at the level of the alveoli. We iterated estimates for functional residual capacity to create the best linear fit of alveolar CO2 pressure and CO2 elimination for 10 minutes of breathing and incorporated the volume of CO2 elimination into the Fick equation to calculate PBF. The relationship between alveolar pressure of CO2 and CO2 elimination produced an R(2) = 0.83. The optimal functional residual capacity differed from the "actual" capacity by 0.25 L (8.3%). The repeatability coefficient leveled at 0.09 at 10 breaths and the difference between the PBF calculated by the model and the preset blood flow was 0.62 ± 0.53 L/minute. With variations in tidal breathing, a linear relationship exists between alveolar CO2 pressure and CO2 elimination. Existing technology may be used to calculate CO2 elimination during quiet breathing and might therefore be used to accurately calculate PBF in humans with healthy lungs.

  16. Predictors of sleep disordered breathing in children: the PANIC study.

    PubMed

    Ikävalko, Tiina; Närhi, Matti; Eloranta, Aino-Maija; Lintu, Niina; Myllykangas, Riitta; Vierola, Anu; Tuomilehto, Henri; Lakka, Timo; Pahkala, Riitta

    2018-05-25

    We studied longitudinally the associations of craniofacial morphology, mouth breathing, orthodontic treatment, and body fat content with the risk of having and developing sleep disordered breathing (SDB) in childhood. We hypothesized that deviant craniofacial morphology, mouth breathing, and adiposity predict SDB among children. The participants were 412 children 6-8 years of age examined at baseline and 329 children aged 9-11 years re-examined at an average 2.2-year follow-up. An experienced orthodontist evaluated facial proportions, dental occlusion, soft tissue structures, and mode of breathing and registered malocclusions in orthodontic treatment. Body fat percentage was assessed by dual-energy X-ray absorptiometry and SDB symptoms by a questionnaire. Children with SDB more likely had convex facial profile, increased lower facial height, mandibular retrusion, tonsillar hypertrophy, and mouth breathing at baseline and convex facial profile, mandibular retrusion, and mouth breathing at follow-up than children without SDB at these examinations. Male gender and body adiposity, mouth breathing, and distal molar occlusion at baseline were associated with SDB later in childhood. Adipose tissue under the chin, mandibular retrusion, vertically large or normal throat and malocclusion in orthodontic treatment at baseline predicted developing SDB during follow-up of among children without SDB at baseline. We could not conduct polysomnographic examinations to define sleep disturbances. Instead, we used a questionnaire filled out by the parents to assess symptoms of SDB. The results indicate that among children, deviant craniofacial morphology, mouth breathing, body adiposity, and male gender seem to have implications in the pathophysiology of SDB.

  17. Sex Differences in the Prevalence and Modulators of Sleep-Disordered Breathing in Outpatients with Type 2 Diabetes

    PubMed Central

    Kroner, T.; Arzt, M.; Rheinberger, M.; Gorski, M.; Heid, I. M.; Böger, C. A.

    2018-01-01

    In patients with type 2 diabetes, sleep-disordered breathing is a widespread cause of deteriorated quality of life. However, robust prevalence estimates for sleep-disordered breathing in patients with type 2 diabetes are limited due to scarce data. We investigated sex differences in sleep-disordered breathing prevalence and its modulators in the DIACORE SDB substudy, a sample of outpatient type 2 diabetes. 721 participants were tested for sleep-disordered breathing using a two-channel sleep apnoea monitoring device. Patients were stratified according to the severity of sleep-disordered breathing, defined as an apnoea-hypopnoea index < 15, ≥15 to 29, and ≥30 events per hour as no/mild, moderate, and severe sleep-disordered breathing, respectively. In the 679 analysed patients (39% women, age 66 ± 9 years, body mass index 31.0 ± 5.4 kg/m2), the prevalence of sleep-disordered breathing was 34%. The prevalence of sleep-disordered breathing was higher in men than in women (41% versus 22%, p < 0.001) and increased with age (15%, 21%, and 30% in women and 35%, 40%, and 47% in men in those aged 18–59, 60–69, or ≥70, respectively; age trend p = 0.064 in women and p = 0.15 in men). In linear regression analysis, age, BMI, and waist-hip ratio were associated with apnoea-hypopnoea index. Modulators for higher apnoea-hypopnoea index seem to be similar in men and women. PMID:29805982

  18. Chest physiotherapy and breathing exercises for cardiac surgery patients in Sweden--a national survey of practice.

    PubMed

    Westerdahl, E; Olsén, M Fagevik

    2011-06-01

    Various chest physiotherapy techniques are recommended after cardiac surgery around the world. There is limited published data on what breathing exercises actually are recommended to patients after surgery in Europe. The aim of this national survey was to establish the current practice of chest physiotherapy and breathing exercises for adult patients following cardiac surgery in Sweden. A postal questionnaire was sent to a total population sample of 33 Swedish physiotherapists working at the departments of cardiothoracic surgery in December 2007 and January 2008. In total, 29 replies (88%) were received. Seven male and twenty two female physiotherapists completed the questionnaire. All physiotherapists instructed, on a regular basis, the cardiac surgery patients to perform post-operative breathing exercises. Positive expiratory pressure (PEP) breathing was routinely used as the first choice for treatment by 22 (83%) of the physiotherapists. Expiratory pressures used varied between 2 and 20 cm H2O. Recommended frequency and duration of the exercises varied from 4 to 30 breaths hourly during the daytime in the first post-operative days. All physiotherapists provided coughing support to the patients. Recommendations to continue breathing exercises after discharge varied from not at all up to 3 months after surgery. Breathing exercises are regularly prescribed during the initial post-operative days after cardiac surgery in Sweden. Hourly deep breathing exercises performed with or without a PEP device were reported to be first choice treatments during the hospital stay. Instructions concerning how long patients should continue the exercises after discharge varied notably.

  19. NICMOS Focus and HST Breathing

    NASA Astrophysics Data System (ADS)

    Suchkov, A.; Hershey, J.

    1998-09-01

    The program 7608 monitored on a biweekly basis NICMOS camera foci from June 9, 1997, through February 18, 1998. Each of the biweekly observations included 17 measurements of focus position (focus sweeps), individually for each of the three cameras. The measurements for camera 1 and camera 3 foci covered one or two HST orbital periods. Comparison of these measurements with the predictions of the three OTA focus breathing models has shown the following. (1). Focus variations seen in NICMOS focus sweeps correlate well with the OTA focus thermal breathing as predicted by breathing models (“4- temperature”, “full-temperature”, and “attitude” models). Thus they can be attributed mostly to the HST orbital temperature variation. (2). The amount of breathing (breathing amplitude) has been found to be on average larger in the first orbit after a telescope slew to a new target. This is explained as being due to additional thermal perturbations caused by the change in the HST attitude as the telescope repoints to a new target. (3). In the first orbit, the amount of focus change predicted by the 4-temperature model is about the same as that seen in the focus sweeps data (breathing scale factor ~1). However the full-temperature model predicts a two times smaller breathing amplitude (breathing scale factor ~1.7). This suggests that the light shield temperatures are more responsive to the attitude change than temperatures from the other temperature sensors. The results of this study may help to better understand the HST thermal cycles and to improve the models describing the impact of those on both the OTA and NICMOS focus.

  20. Advances in chemical sensing technologies for VOCs in breath for security/threat assessment, illicit drug detection, and human trafficking activity.

    PubMed

    Giannoukos, S; Agapiou, A; Taylor, S

    2018-01-17

    On-site chemical sensing of compounds associated with security and terrorist attacks is of worldwide interest. Other related bio-monitoring topics include identification of individuals posing a threat from illicit drugs, explosive manufacturing, as well as searching for victims of human trafficking and collapsed buildings. The current status of field analytical technologies is directed towards the detection and identification of vapours and volatile organic compounds (VOCs). Some VOCs are associated with exhaled breath, where research is moving from individual breath testing (volatilome) to cell breath (microbiome) and most recently to crowd breath metabolites (exposome). In this paper, an overview of field-deployable chemical screening technologies (both stand-alone and those with portable characteristics) is given with application to early detection and monitoring of human exposome in security operations. On-site systems employed in exhaled breath analysis, i.e. mass spectrometry (MS), optical spectroscopy and chemical sensors are reviewed. Categories of VOCs of interest include (a) VOCs in human breath associated with exposure to threat compounds, and (b) VOCs characteristic of, and associated with, human body odour (e.g. breath, sweat). The latter are relevant to human trafficking scenarios. New technological approaches in miniaturised detection and screening systems are also presented (e.g. non-scanning digital light processing linear ion trap MS (DLP-LIT-MS), nanoparticles, mid-infrared photo-acoustic spectroscopy and hyphenated technologies). Finally, the outlook for rapid and precise, real-time field detection of threat traces in exhaled breath is revealed and discussed.

  1. Upper airway sleep-disordered breathing in women.

    PubMed

    Guilleminault, C; Stoohs, R; Kim, Y D; Chervin, R; Black, J; Clerk, A

    1995-04-01

    To investigate the various clinical presentations of sleep-disordered breathing in women. A retrospective case-control study. A sleep disorders clinic. 334 women, aged 18 years and older, seen between 1988 and 1993, who were diagnosed with upper airway sleep-disordered breathing. Controls were 60 women with insomnia and 100 men with sleep-disordered breathing. Clinical, anatomic, and polygraphic information. The mean lag time (+/- SD) in women between the appearance of symptoms and a positive diagnosis was 9.7 +/- 3.1 years; among participants 30 to 60 years of age, the duration of untreated symptoms differed (P < 0.001) between women and men. Sleep-disordered breathing was blamed for divorce or social isolation by 40% of the case patients. Abnormal maxillomandibular features were noted in 45% of the women with disordered breathing. Dysmenorrhea and amenorrhea (which disappeared after treatment with nasal continuous positive airway pressure) were reported in 43% of premenopausal women compared with 13% of persons in the control group of women with insomnia. Thirty-eight women (11.4%) with upper airway sleep-disordered breathing had a respiratory disturbance index of less than 5 and were significantly younger, had a smaller neck circumference, and had a lower body mass index than women with a respiratory disturbance index of 5 or more. Physicians should revise their understanding of upper airway sleep-disordered breathing so that they notice women with certain craniofacial features, a low body mass index, a small neck circumference, and a respiratory disturbance index of less than 5. These revisions may enable more rapid diagnosis and treatment of women with sleep-disordered breathing.

  2. The effect of deep and slow breathing on pain perception, autonomic activity, and mood processing--an experimental study.

    PubMed

    Busch, Volker; Magerl, Walter; Kern, Uwe; Haas, Joachim; Hajak, Göran; Eichhammer, Peter

    2012-02-01

    Deep and slow breathing (DSB) techniques, as a component of various relaxation techniques, have been reported as complementary approaches in the treatment of chronic pain syndromes, but the relevance of relaxation for alleviating pain during a breathing intervention was not evaluated so far. In order to disentangle the effects of relaxation and respiration, we investigated two different DSB techniques at the same respiration rates and depths on pain perception, autonomic activity, and mood in 16 healthy subjects. In the attentive DSB intervention, subjects were asked to breathe guided by a respiratory feedback task requiring a high degree of concentration and constant attention. In the relaxing DSB intervention, the subjects relaxed during the breathing training. The skin conductance levels, indicating sympathetic tone, were measured during the breathing maneuvers. Thermal detection and pain thresholds for cold and hot stimuli and profile of mood states were examined before and after the breathing sessions. The mean detection and pain thresholds showed a significant increase resulting from the relaxing DSB, whereas no significant changes of these thresholds were found associated with the attentive DSB. The mean skin conductance levels indicating sympathetic activity decreased significantly during the relaxing DSB intervention but not during the attentive DSB. Both breathing interventions showed similar reductions in negative feelings (tension, anger, and depression). Our results suggest that the way of breathing decisively influences autonomic and pain processing, thereby identifying DSB in concert with relaxation as the essential feature in the modulation of sympathetic arousal and pain perception. Wiley Periodicals, Inc.

  3. The application of chromatographic breath analysis in the search of volatile biomarkers of chronic kidney disease and coexisting type 2 diabetes mellitus.

    PubMed

    Grabowska-Polanowska, B; Skowron, M; Miarka, P; Pietrzycka, A; Śliwka, I

    2017-08-15

    Chromatographic studies on breath composition are aimed at finding volatile markers useful for medical diagnostics or in screening investigations. Studies leading to the development of screening breath tests are especially important for the diagnostics of chronic kidney disease (CKD) and type 2 diabetes mellitus (T2DM). The aim of the presented study was to confirm diagnostic usefulness of chosen volatile compounds detected in breath, which are suggested as potential biomarkers of renal dysfunction and diabetes. Breath analysis were carried out in three groups: 10 healthy volunteers, 10 patients with CKD and 10 patients with CKD and T2DM. All exhaled air samples were analyzed using gas chromatograph (Agilent 6890GC) coupled with mass spectrometer (5975MSD). Thermal desorption was applied as the enrichment method. TMA was detected only in CKD patients. Higher breath concentrations of methanethiol (MeSH) were observed in CKD patients with coexisting diabetes than in patients with renal dysfunction only or in the healthy group. There was a tendency of increasing MeSH concentration in breath with increasing total glutathione in plasma (r=0.53, p=0.0026). Also, a trend of increasing dimethylsulfide (DMS) levels detected in breath was noticed with an increase of hydrogen sulfide concentration in plasma (r=0.74; p=0.00001) as well as with aspartate aminotransferase (AST), (r=0.61; p=0.001). The presented results suggest the possibility of applying TMA, MeSH, and DMS detection in breath as diagnostic methods. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Time course of ozone-induced changes in breathing pattern in healthy exercising humans.

    PubMed

    Schelegle, Edward S; Walby, William F; Adams, William C

    2007-02-01

    We examined the time course of O3-induced changes in breathing pattern in 97 healthy human subjects (70 men and 27 women). One- to five-minute averages of breathing frequency (f(B)) and minute ventilation (Ve) were used to generate plots of cumulative breaths and cumulative exposure volume vs. time and cumulative exposure volume vs. cumulative breaths. Analysis revealed a three-phase response; delay, no response detected; onset, f(B) began to increase; response, f(B) stabilized. Regression analysis was used to identify four parameters: time to onset, number of breaths at onset, cumulative inhaled dose of ozone at onset of O3-induced tachypnea, and the percent change in f(B). The effect of altering O3 concentration, Ve, atropine treatment, and indomethacin treatment were examined. We found that the lower the O3 concentration, the greater the number of breaths at onset of tachypnea at a fixed ventilation, whereas number of breaths at onset of tachypnea remains unchanged when Ve is altered and O3 concentration is fixed. The cumulative inhaled dose of O3 at onset of tachypnea remained constant and showed no relationship with the magnitude of percent change in f(B). Atropine did not affect any of the derived parameters, whereas indomethacin did not affect time to onset, number of breaths at onset, or cumulative inhaled dose of O3 at onset of tachypnea but did attenuate percent change in f(B). The results are discussed in the context of dose response and intrinsic mechanisms of action.

  5. Towards the determination of isoprene in human breath using substrate-integrated hollow waveguide mid-infrared sensors.

    PubMed

    Perez-Guaita, David; Kokoric, Vjekoslav; Wilk, Andreas; Garrigues, Salvador; Mizaikoff, Boris

    2014-06-01

    Selected volatile organic compounds (VOCs) in breath may be considered biomarkers if they are indicative of distinct diseases or disease states. Given the inherent molecular selectivity of vibrational spectroscopy, infrared sensing technologies appear ideally suitable for the determination of endogenous VOCs in breath. The aim of this study was to determine that mid-infrared (MIR; 3-20 µm) gas phase sensing is capable of determining isoprene in exhaled breath as an exemplary medically relevant VOC by hyphenating novel substrate-integrated hollow waveguides (iHWG) with a likewise miniaturized preconcentration system. A compact preconcentrator column for sampling isoprene from exhaled breath was coupled to an iHWG serving simultaneously as highly miniaturized gas cell and light conduit in combination with a compact Fourier transform infrared spectrometer. A gas mixing system enabled extensive system calibration using isoprene standards. After system optimization, a calibration function obtaining a limit of quantification of 106 ppb was achieved. According to the literature, the obtained sensitivity is sufficient for quantifying middle to high isoprene concentrations occurring in exhaled breath. Finally, a volunteer breath sample was analysed proving comparable values of isoprene in a real-world scenario. Despite its fundamental utility, the proposed methodology contains some limitations in terms of sensitivity and temporal resolution in comparison with the readily available measurement techniques that should be addressed during future optimization of the system. Nonetheless, this study presents the first determination of endogenous VOCs in breath via advanced hollow waveguide MIR sensor technology, clearly demonstrating its potential for the analysis of volatile biomarkers in exhaled breath.

  6. (13)C-Breath testing in animals: theory, applications, and future directions.

    PubMed

    McCue, Marshall D; Welch, Kenneth C

    2016-04-01

    The carbon isotope values in the exhaled breath of an animal mirror the carbon isotope values of the metabolic fuels being oxidized. The measurement of stable carbon isotopes in carbon dioxide is called (13)C-breath testing and offers a minimally invasive method to study substrate oxidation in vivo. (13)C-breath testing has been broadly used to study human exercise, nutrition, and pathologies since the 1970s. Owing to reduced use of radioactive isotopes and the increased convenience and affordability of (13)C-analyzers, the past decade has witnessed a sharp increase in the use of breath testing throughout comparative physiology--especially to answer questions about how and when animals oxidize particular nutrients. Here, we review the practical aspects of (13)C-breath testing and identify the strengths and weaknesses of different methodological approaches including the use of natural abundance versus artificially-enriched (13)C tracers. We critically compare the information that can be obtained using different experimental protocols such as diet-switching versus fuel-switching. We also discuss several factors that should be considered when designing breath testing experiments including extrinsic versus intrinsic (13)C-labelling and different approaches to model nutrient oxidation. We use case studies to highlight the myriad applications of (13)C-breath testing in basic and clinical human studies as well as comparative studies of fuel use, energetics, and carbon turnover in multiple vertebrate and invertebrate groups. Lastly, we call for increased and rigorous use of (13)C-breath testing to explore a variety of new research areas and potentially answer long standing questions related to thermobiology, locomotion, and nutrition.

  7. Breath stacking in children with neuromuscular disorders.

    PubMed

    Jenkins, H M; Stocki, A; Kriellaars, D; Pasterkamp, H

    2014-06-01

    Respiratory muscle weakness in neuromuscular disorders (NMD) can lead to shallow breathing and respiratory insufficiency over time. Children with NMD often cannot perform maneuvers to recruit lung volume. In adults, breath stacking with a mask and one-way valve can achieve significantly increased lung volumes. To evaluate involuntary breath stacking (IBS) in NMD, we studied 23 children of whom 15 were cognitively aware and able to communicate verbally. For IBS, a one-way valve and pneumotachograph were attached to a face mask. Tidal volumes (Vt) and minute ventilation (VE ) were calculated from airflow over 30 sec before and after 15 sec of expiratory valve closure. Six cooperative male subjects with Duchenne muscular dystrophy (DMD) participated in a subsequent comparison of IBS with voluntary breath stacking (VBS) and supported breath stacking (SBS). The average Vt in those studied with IBS was 277 ml (range 29-598 ml). The average increase in volume by stacking was 599 ml (range -140 to 2,916 ml) above Vt . The average number of stacked breaths was 4.5 (range 0-17). VE increased on average by 18% after stacking (P < 0.05, paired t-test). Oxygen saturation did not change after stacking. Four of the 23 children did not breath stack. Compared to IBS, VBS achieved similar volumes in the six subjects with DMD but SBS was more successful in those with greatest muscle weakness. IBS may achieve breath volumes of approximately three times Vt and may be particularly useful in non-cooperative subjects with milder degrees of respiratory muscle weakness. © 2013 Wiley Periodicals, Inc.

  8. ALVEOLAR BREATH SAMPLING AND ANALYSIS IN HUMAN EXPOSURE ASSESSMENT STUDIES

    EPA Science Inventory

    Alveolar breath sampling and analysis can be extremely useful in exposure assessment studies involving volatile organic compounds (VOCs). Over recent years scientists from the EPA's National Exposure Research Laboratory have developed and refined an alveolar breath collection ...

  9. Deposition of Aerosols in the Lung: Physiological Factors

    EPA Science Inventory

    Ventilation and mechanics of breathing are an integral part of respiratory physiology that directly affect aerosol transport and deposition in the lung. Although natural breathing pattern varies widely among individuals, breathing pattern is controllable, and by using an appropri...

  10. Pulmonary Function Testing in Children

    MedlinePlus

    ... breathing test. About 15 minutes after taking the medicine, your child will repeat the breathing test. The results from ... the first test to find out if the medicine has improved your child’s breathing. Why shouldn’t I give my child ...

  11. Development enhances hypometabolism in northern elephant seal pups (Mirounga angustirostris)

    PubMed Central

    Tift, Michael S.; Ranalli, Elizabeth C.; Houser, Dorian S.; Ortiz, Rudy M.; Crocker, Daniel E.

    2013-01-01

    Summary Investigation into the development of oxygen storage capacity in air-breathing marine predators has been performed, but little is known about the development of regulatory factors that influence oxygen utilization. Strategies for efficiently using oxygen stores should enable marine predators to optimize time spent foraging underwater. We describe the developmental patterns of oxygen use during voluntary breath-holds in northern elephant seals (Mirounga angustirostris) at 2 and 7 weeks post-weaning. We measured 1) changes in oxygen consumption (VO2), and 2) changes in venous pH, partial pressure of oxygen (pO2), haemoglobin saturation (sO2), oxygen content (O2ct), partial pressure of carbon dioxide (pCO2), haematocrit (Hct) and total haemoglobin (tHb). To examine the effect of the dive response on the development of oxygen utilization, voluntary breath-hold experiments were conducted in and out of water. Suppression of VO2 during voluntary breath-holds increased significantly between 2 and 7 weeks post-weaning, reaching a maximum suppression of 53% below resting metabolic rate and 56% below Kleiber’s standard metabolic rate. From 2 to 7 weeks post-weaning, breath-hold VO2 was reduced by 52%. Between the two age classes, this equates to a mean breath-hold VO2 reduction of 16% from resting VO2. Breath-hold VO2 also declined with increasing breath-hold duration, but there was no direct effect of voluntary submergence on reducing VO2. Age did not influence rates of venous pO2 depletion during breath-holds. However, voluntary submergence did result in slower pO2 depletion rates when compared to voluntary terrestrial apnoeas. The differences in whole body VO2 during breath-holds (measured at recovery) and venous pO2 (reflective of tissue O2-use measured during breath-holds), likely reflects metabolic suppression in hypoxic, vasoconstricted tissues. Consistent pCO2 values at the end of all voluntary breath-holds (59.0 ± 0.7 mmHg) suggests the physiological cue for stimulating respiration in northern elephant seal pups is the accumulation of CO2. Oxygen storage capacity and metabolic suppression directly limit diving capabilities and may influence foraging success in low-weaning weight seals forced to depart to sea prior to achieving full developmental diving capacity. PMID:24187422

  12. Prediction of heart transplant rejection with a breath test for markers of oxidative stress.

    PubMed

    Phillips, Michael; Boehmer, John P; Cataneo, Renee N; Cheema, Taseer; Eisen, Howard J; Fallon, John T; Fisher, Peter E; Gass, Alan; Greenberg, Joel; Kobashigawa, Jon; Mancini, Donna; Rayburn, Barry; Zucker, Mark J

    2004-12-15

    The Heart Allograft Rejection: Detection with Breath Alkanes in Low Levels study evaluated a breath test for oxidative stress in heart transplant recipients, and we report here a mathematical model predicting the probability of grade 3 rejection. The breath test divided the heart transplant recipients into 3 groups: positive for grade 3 rejection, negative for grade 3 rejection, and intermediate. The test was 100% sensitive for grade 3 heart transplant rejection when the p value was >/=0.98, and 100% specific when the p value was

  13. Automatic Recognition of Breathing Route During Sleep Using Snoring Sounds

    NASA Astrophysics Data System (ADS)

    Mikami, Tsuyoshi; Kojima, Yohichiro

    This letter classifies snoring sounds into three breathing routes (oral, nasal, and oronasal) with discriminant analysis of the power spectra and k-nearest neighbor method. It is necessary to recognize breathing route during snoring, because oral snoring is a typical symptom of sleep apnea but we cannot know our own breathing and snoring condition during sleep. As a result, about 98.8% classification rate is obtained by using leave-one-out test for performance evaluation.

  14. Air-Breathing Ramjet Electric Propulsion for Controlling Low-Orbit Spacecraft Motion to Compensate for Aerodynamic Drag

    NASA Astrophysics Data System (ADS)

    Erofeev, A. I.; Nikiforov, A. P.; Popov, G. A.; Suvorov, M. O.; Syrin, S. A.; Khartov, S. A.

    2017-12-01

    Problems on designing the air-breathing ramjet electric propulsion thruster for controlling loworbit spacecraft motion are examined in the paper. Information for choosing orbits' altitudes for reasonable application of an air-breathing ramjet electric propulsion thruster and propellant exhaust velocity is presented. Estimates of the probable increase of gas concentration in the area of air-breathing ramjet ionization are presented. The test results of the thruster are also given.

  15. Breath alcohol analysis incorporating standardization to water vapour is as precise as blood alcohol analysis.

    PubMed

    Grubb, D; Rasmussen, B; Linnet, K; Olsson, S G; Lindberg, L

    2012-03-10

    A novel breath-alcohol analyzer based on the standardization of the breath alcohol concentration (BrAC) to the alveolar-air water vapour concentration has been developed and evaluated. The present study compares results with this particular breath analyzer with arterial blood alcohol concentrations (ABAC), the most relevant quantitative measure of brain alcohol exposure. The precision of analysis of alcohol in arterial blood and breath were determined as well as the agreement between ABAC and BrAC over time post-dosing. Twelve healthy volunteers were administered 0.6g alcohol/kg bodyweight via an orogastric tube. Duplicate breath and arterial blood samples were obtained simultaneously during the absorption, distribution and elimination phases of the alcohol metabolism with particular emphasis on the absorption phase. The precision of the breath analyzer was similar to the determination of blood alcohol concentration by headspace gas chromatography (CV 2.40 vs. 2.38%, p=0.43). The ABAC/BrAC ratio stabilized 30min post-dosing (2089±99; mean±SD). Before this the BrAC tended to underestimate the coexisting ABAC. In conclusion, breath alcohol analysis utilizing standardization of alcohol to water vapour was as precise as blood alcohol analysis, the present "gold standard" method. The BrAC reliably predicted the coexisting ABAC from 30min onwards after the intake of alcohol. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  16. Chemical analysis of whale breath volatiles: a case study for non-invasive field health diagnostics of marine mammals.

    PubMed

    Cumeras, Raquel; Cheung, William H K; Gulland, Frances; Goley, Dawn; Davis, Cristina E

    2014-09-12

    We explored the feasibility of collecting exhaled breath from a moribund gray whale (Eschrichtius robustus) for potential non-invasive health monitoring of marine mammals. Biogenic volatile organic compound (VOC) profiling is a relatively new field of research, in which the chemical composition of breath is used to non-invasively assess the health and physiological processes on-going within an animal or human. In this study, two telescopic sampling poles were designed and tested with the primary aim of collecting whale breath exhalations (WBEs). Once the WBEs were successfully collected, they were immediately transferred onto a stable matrix sorbent through a custom manifold system. A total of two large volume WBEs were successfully captured and pre-concentrated onto two Tenax®-TA traps (one exhalation per trap). The samples were then returned to the laboratory where they were analyzed using solid phase micro extraction (SPME) and gas chromatography/mass spectrometry (GC/MS). A total of 70 chemicals were identified (58 positively identified) in the whale breath samples. These chemicals were also matched against a database of VOCs found in humans, and 44% of chemicals found in the whale breath are also released by healthy humans. The exhaled gray whale breath showed a rich diversity of chemicals, indicating the analysis of whale breath exhalations is a promising new field of research.

  17. Breath volatile organic compounds for the gut-fatty liver axis: Promise, peril, and path forward

    PubMed Central

    Solga, Steven Francis

    2014-01-01

    The worldwide interest in the gut microbiome and its impact on the upstream liver highlight a critical upside to breath research: it can uniquely measure otherwise unmeasurable biology. Bacteria make gases [volatile organic compounds (VOCs)] that are directly relevant to pathophysiology of the fatty liver and associated conditions, including obesity. Measurement of these VOCs and their metabolites in the exhaled breath, therefore, present an opportunity to safely and easily evaluate, on both a personal and a population level, some of our most pressing public health threats. This is an opportunity that must be pursued. To date, however, breath analysis remains a slowly evolving field which only occasionally impacts clinical research or patient care. One major obstacle to progress is that breath analysis is inherently and emphatically mutli-disciplinary: it connects engineering, chemistry, breath mechanics, biology and medicine. Unbalanced or incomplete teams may produce inconsistent and often unsatisfactory results. A second impediment is the lack of a well-known stepwise structure for the development of non-invasive diagnostics. As a result, the breath research landscape is replete with orphaned single-center pilot studies. Often, important hypotheses and key observations have not been pursued to maturation. This paper reviews the rationale and requirements for breath VOC research applied to the gut-fatty liver axis and offers some suggestions for future development. PMID:25083075

  18. Sleep-disordered breathing in epilepsy: epidemiology, mechanisms, and treatment.

    PubMed

    Sivathamboo, Shobi; Perucca, Piero; Velakoulis, Dennis; Jones, Nigel C; Goldin, Jeremy; Kwan, Patrick; O'Brien, Terence J

    2018-04-01

    Epilepsy is a group of neurological conditions in which there is a pathological and enduring predisposition to generate recurrent seizures. Evidence over the last few decades suggests that epilepsy may be associated with increased sleep-disordered breathing, which may contribute towards sleep fragmentation, daytime somnolence, reduced seizure control, and cardiovascular-related morbidity and mortality. Chronic sleep-disordered breathing can result in loss of gray matter and cause deficits to memory and global cognitive function. Sleep-disordered breathing is a novel and independent predictor of sudden cardiac death and, as such, may be involved in the mechanisms leading to sudden unexpected death in epilepsy. Despite this, the long-term consequences of sleep-disordered breathing in epilepsy remain unknown, and there are no guidelines for screening or treating this population. There is currently insufficient evidence to indicate continuous positive airway pressure (CPAP) for the primary or secondary prevention of cardiovascular disease, and recent evidence has failed to show any reduction of fatal or nonfatal cardiovascular endpoints. Treatment of sleep-disordered breathing may potentially improve seizure control, daytime somnolence, and neurocognitive outcomes, but few studies have examined this relationship. In this review, we examine sleep-disordered breathing in epilepsy, and discuss the potential effect of epilepsy treatments. We consider the role of CPAP and other interventions for sleep-disordered breathing and discuss their implications for epilepsy management.

  19. The effects of inspiratory diaphragm breathing exercise and expiratory pursed-lip breathing exercise on chronic stroke patients' respiratory muscle activation.

    PubMed

    Seo, KyoChul; Hwan, Park Seung; Park, KwangYong

    2017-03-01

    [Purpose] The purpose of this study is to examine the effects of inspiratory diaphragm breathing exercise and expiratory pursed-lip breathing exercise on chronic stroke patients' respiratory muscle activation. [Subjects and Methods] All experimental subjects performed exercises five times per week for four weeks. Thirty chronic stroke patients were randomly assign to an experimental group of 15 patients and a control group of 15 patients. The experimental group underwent exercises consisting of basic exercise treatment for 15 minutes and inspiratory diaphragm breathing exercise and expiratory pursed-lip breathing exercise for 15 minutes and the control group underwent exercises consisting of basic exercise treatment for 15 minutes and auto-med exercise for 15 minutes. The activation levels of respiratory muscles were measured before and after the experiment using MP 150WSW to obtain the results of the experiment. [Results] In the present study, when the pulmonary functions of the experimental group and the control group before and after the experiment were compared, whereas the experimental group showed significant differences in all sections. In the verification of intergroup differences between the experimental group and the control group before and after the experiment. [Conclusion] The respiratory rehabilitation exercise is considered to be capable of inducing positive effects on stroke patients' respiratory muscles through diaphragm breathing exercise and lip puckering breathing exercise.

  20. Enriched Air Nitrox Breathing Reduces Venous Gas Bubbles after Simulated SCUBA Diving: A Double-Blind Cross-Over Randomized Trial.

    PubMed

    Souday, Vincent; Koning, Nick J; Perez, Bruno; Grelon, Fabien; Mercat, Alain; Boer, Christa; Seegers, Valérie; Radermacher, Peter; Asfar, Pierre

    2016-01-01

    To test the hypothesis whether enriched air nitrox (EAN) breathing during simulated diving reduces decompression stress when compared to compressed air breathing as assessed by intravascular bubble formation after decompression. Human volunteers underwent a first simulated dive breathing compressed air to include subjects prone to post-decompression venous gas bubbling. Twelve subjects prone to bubbling underwent a double-blind, randomized, cross-over trial including one simulated dive breathing compressed air, and one dive breathing EAN (36% O2) in a hyperbaric chamber, with identical diving profiles (28 msw for 55 minutes). Intravascular bubble formation was assessed after decompression using pulmonary artery pulsed Doppler. Twelve subjects showing high bubble production were included for the cross-over trial, and all completed the experimental protocol. In the randomized protocol, EAN significantly reduced the bubble score at all time points (cumulative bubble scores: 1 [0-3.5] vs. 8 [4.5-10]; P < 0.001). Three decompression incidents, all presenting as cutaneous itching, occurred in the air versus zero in the EAN group (P = 0.217). Weak correlations were observed between bubble scores and age or body mass index, respectively. EAN breathing markedly reduces venous gas bubble emboli after decompression in volunteers selected for susceptibility for intravascular bubble formation. When using similar diving profiles and avoiding oxygen toxicity limits, EAN increases safety of diving as compared to compressed air breathing. ISRCTN 31681480.

  1. Cardiorespiratory interactions during resistive load breathing.

    PubMed

    Calabrese, P; Perrault, H; Dinh, T P; Eberhard, A; Benchetrit, G

    2000-12-01

    The addition to the respiratory system of a resistive load results in breathing pattern changes and in negative intrathoracic pressure increases. The aim of this study was to use resistive load breathing as a stimulus to the cardiorespiratory interaction and to examine the extent of the changes in heart rate variability (HRV) and respiratory sinus arrhythmia (RSA) in relation to the breathing pattern changes. HRV and RSA were studied in seven healthy subjects where four resistive loads were applied in a random order during the breath and 8-min recording made in each condition. The HRV spectral power components were computed from the R-R interval sequences, and the RSA amplitude and phase were computed from the sinusoid fitting the instantaneous heart rate within each breath. Adding resistive loads resulted in 1) increasing respiratory period, 2) unchanging heart rate, and 3) increasing HRV and changing RSA characteristics. HRV and RSA characteristics are linearly correlated to the respiratory period. These modifications appear to be linked to load-induced changes in the respiratory period in each individual, because HRV and RSA characteristics are similar at a respiratory period obtained either by loading or by imposed frequency breathing. The present results are discussed with regard to the importance of the breathing cycle duration in these cardiorespiratory interactions, suggesting that these interactions may depend on the time necessary for activation and dissipation of neurotransmitters involved in RSA.

  2. Direct analysis of human breath ammonia using corona discharge ion mobility spectrometry.

    PubMed

    Jazan, Elham; Mirzaei, Hadi

    2014-01-01

    In this study, ammonia in human breath was directly determined using corona discharge ionization ion mobility spectrometry (CD-IMS) technique with several important advantages including high sensitivity, low cost, high speed, and ease of maintenance. The temperature effect on the ammonia signal was evaluated too. The results indicated that the best temperature for the investigation of breath ammonia was 150°C. The analytical results showed that the linear dynamic range was between 12 and 810ppb and the detection limit was 6.6ppb. The relative standard deviation (RSD) was obtained to be 5, 3, and 3 for 290, 348, and 522ppb, respectively. The amounts of ammonia in breath of eight healthy volunteers were measured. The values were between 236 and 1218ppb. Also, the inequality in breath ammonia levels was scrutinized over a 6h working day for three healthy volunteers. The results showed a drop in breath ammonia from the morning amount to the mid-day measurement and then, a progressive increase while the day continued. In addition, the amounts of ammonia were determined to be 1494-1553ppb in exhaled breath of two renal failure patients. The results obtained in this work revealed that the method was conveniently established without any considerable sample pretreatment for direct analysis of ammonia in human breath. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. Facial type and head posture of nasal and mouth-breathing children.

    PubMed

    Bolzan, Geovana de Paula; Souza, Juliana Alves; Boton, Luane de Moraes; Silva, Ana Maria Toniolo da; Corrêa, Eliane Castilhos Rodrigues

    2011-12-01

    To verify the facial type and the head posture of nasal and mouth-breathing children from habitual and obstructive etiologies, as well as to correlate the morphological facial index to the head angulation position in the sagittal plane. Participants were 59 children with ages between 8 years and 11 years and 10 months. All subjects were undergone to speech-language pathology screening, otorhinolaryngologic evaluation, and nasopharyngoscopy, allowing the constitution of three groups: nasal breathers--15 children; mouth breathers from obstructive etiology--22 children; and habitual mouth breathers--22 children. In order to determine facial type and morphological facial index, the height and the width of the face were measured using a digital caliper. The head posture was assessed through physical examination and computerized photogrammetry. It was verified the predominance of short face in nasal breathers, and long face in mouth breathers. There was an association among facial type and breathing mode/mouth breathing etiology: the brachyfacial type was more frequent among nasal breathers, and less frequent in subjects with obstructive nasal breathing. Head posture was similar in all three groups. No correlation was found between morphological facial index and head posture. The brachyfacial type favors the nasal-breathing mode and the head posture is not influenced by breathing mode and by the etiology of mouth breathing, as well as it is not related to facial type.

  4. Prediction of breast cancer risk with volatile biomarkers in breath.

    PubMed

    Phillips, Michael; Cataneo, Renee N; Cruz-Ramos, Jose Alfonso; Huston, Jan; Ornelas, Omar; Pappas, Nadine; Pathak, Sonali

    2018-03-23

    Human breath contains volatile organic compounds (VOCs) that are biomarkers of breast cancer. We investigated the positive and negative predictive values (PPV and NPV) of breath VOC biomarkers as indicators of breast cancer risk. We employed ultra-clean breath collection balloons to collect breath samples from 54 women with biopsy-proven breast cancer and 124 cancer-free controls. Breath VOCs were analyzed with gas chromatography (GC) combined with either mass spectrometry (GC MS) or surface acoustic wave detection (GC SAW). Chromatograms were randomly assigned to a training set or a validation set. Monte Carlo analysis identified significant breath VOC biomarkers of breast cancer in the training set, and these biomarkers were incorporated into a multivariate algorithm to predict disease in the validation set. In the unsplit dataset, the predictive algorithms generated discriminant function (DF) values that varied with sensitivity, specificity, PPV and NPV. Using GC MS, test accuracy = 90% (area under curve of receiver operating characteristic in unsplit dataset) and cross-validated accuracy = 77%. Using GC SAW, test accuracy = 86% and cross-validated accuracy = 74%. With both assays, a low DF value was associated with a low risk of breast cancer (NPV > 99.9%). A high DF value was associated with a high risk of breast cancer and PPV rising to 100%. Analysis of breath VOC samples collected with ultra-clean balloons detected biomarkers that accurately predicted risk of breast cancer.

  5. Air-breathing fishes in aquaculture. What can we learn from physiology?

    PubMed

    Lefevre, S; Wang, T; Jensen, A; Cong, N V; Huong, D T T; Phuong, N T; Bayley, M

    2014-03-01

    During the past decade, the culture of air-breathing fish species has increased dramatically and is now a significant global source of protein for human consumption. This development has generated a need for specific information on how to maximize growth and minimize the environmental effect of culture systems. Here, the existing data on metabolism in air-breathing fishes are reviewed, with the aim of shedding new light on the oxygen requirements of air-breathing fishes in aquaculture, reaching the conclusion that aquatic oxygenation is much more important than previously assumed. In addition, the possible effects on growth of the recurrent exposure to deep hypoxia and associated elevated concentrations of carbon dioxide, ammonia and nitrite, that occurs in the culture ponds used for air-breathing fishes, are discussed. Where data on air-breathing fishes are simply lacking, data for a few water-breathing species will be reviewed, to put the physiological effects into a growth perspective. It is argued that an understanding of air-breathing fishes' respiratory physiology, including metabolic rate, partitioning of oxygen uptake from air and water in facultative air breathers, the critical oxygen tension, can provide important input for the optimization of culture practices. Given the growing importance of air breathers in aquaculture production, there is an urgent need for further data on these issues. © 2014 The Fisheries Society of the British Isles.

  6. Breath-hold imaging of the coronary arteries using Quiescent-Interval Slice-Selective (QISS) magnetic resonance angiography: pilot study at 1.5 Tesla and 3 Tesla.

    PubMed

    Edelman, Robert R; Giri, S; Pursnani, A; Botelho, M P F; Li, W; Koktzoglou, I

    2015-11-23

    Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enhanced, quiescent-interval slice-selective (QISS) 2D technique. Sequence performance was compared at 1.5 and 3 Tesla using both radial and Cartesian k-space trajectories. The left coronary circulation was imaged in six healthy subjects and two patients with coronary artery disease. Breath-hold QISS was compared with T2-prepared 2D balanced steady-state free-precession (bSSFP) and free-breathing, navigator-gated 3D bSSFP. Approximately 10 2.1-mm thick slices were acquired in a single ~20-s breath-hold using two-shot QISS. QISS contrast-to-noise ratio (CNR) was 1.5-fold higher at 3 Tesla than at 1.5 Tesla. Cartesian QISS provided the best coronary-to-myocardium CNR, whereas radial QISS provided the sharpest coronary images. QISS image quality exceeded that of free-breathing 3D coronary MRA with few artifacts at either field strength. Compared with T2-prepared 2D bSSFP, multi-slice capability was not restricted by the specific absorption rate at 3 Tesla and pericardial fluid signal was better suppressed. In addition to depicting the coronary arteries, QISS could image intra-cardiac structures, pericardium, and the aortic root in arbitrary slice orientations. Breath-hold QISS is a simple, versatile, and time-efficient method for coronary MRA that provides excellent image quality at both 1.5 and 3 Tesla. Image quality exceeded that of free-breathing, navigator-gated 3D MRA in a much shorter scan time. QISS also allowed rapid multi-slice bright-blood, diastolic phase imaging of the heart, which may have complementary value to multi-phase cine imaging. We conclude that, with further clinical validation, QISS might provide an efficient alternative to commonly used free-breathing coronary MRA techniques.

  7. Effects of ion channel noise on neural circuits: an application to the respiratory pattern generator to investigate breathing variability.

    PubMed

    Yu, Haitao; Dhingra, Rishi R; Dick, Thomas E; Galán, Roberto F

    2017-01-01

    Neural activity generally displays irregular firing patterns even in circuits with apparently regular outputs, such as motor pattern generators, in which the output frequency fluctuates randomly around a mean value. This "circuit noise" is inherited from the random firing of single neurons, which emerges from stochastic ion channel gating (channel noise), spontaneous neurotransmitter release, and its diffusion and binding to synaptic receptors. Here we demonstrate how to expand conductance-based network models that are originally deterministic to include realistic, physiological noise, focusing on stochastic ion channel gating. We illustrate this procedure with a well-established conductance-based model of the respiratory pattern generator, which allows us to investigate how channel noise affects neural dynamics at the circuit level and, in particular, to understand the relationship between the respiratory pattern and its breath-to-breath variability. We show that as the channel number increases, the duration of inspiration and expiration varies, and so does the coefficient of variation of the breath-to-breath interval, which attains a minimum when the mean duration of expiration slightly exceeds that of inspiration. For small channel numbers, the variability of the expiratory phase dominates over that of the inspiratory phase, and vice versa for large channel numbers. Among the four different cell types in the respiratory pattern generator, pacemaker cells exhibit the highest sensitivity to channel noise. The model shows that suppressing input from the pons leads to longer inspiratory phases, a reduction in breathing frequency, and larger breath-to-breath variability, whereas enhanced input from the raphe nucleus increases breathing frequency without changing its pattern. A major source of noise in neuronal circuits is the "flickering" of ion currents passing through the neurons' membranes (channel noise), which cannot be suppressed experimentally. Computational simulations are therefore the best way to investigate the effects of this physiological noise by manipulating its level at will. We investigate the role of noise in the respiratory pattern generator and show that endogenous, breath-to-breath variability is tightly linked to the respiratory pattern. Copyright © 2017 the American Physiological Society.

  8. Blinded Validation of Breath Biomarkers of Lung Cancer, a Potential Ancillary to Chest CT Screening

    PubMed Central

    Phillips, Michael; Bauer, Thomas L.; Cataneo, Renee N.; Lebauer, Cassie; Mundada, Mayur; Pass, Harvey I.; Ramakrishna, Naren; Rom, William N.; Vallières, Eric

    2015-01-01

    Background Breath volatile organic compounds (VOCs) have been reported as biomarkers of lung cancer, but it is not known if biomarkers identified in one group can identify disease in a separate independent cohort. Also, it is not known if combining breath biomarkers with chest CT has the potential to improve the sensitivity and specificity of lung cancer screening. Methods Model-building phase (unblinded): Breath VOCs were analyzed with gas chromatography mass spectrometry in 82 asymptomatic smokers having screening chest CT, 84 symptomatic high-risk subjects with a tissue diagnosis, 100 without a tissue diagnosis, and 35 healthy subjects. Multiple Monte Carlo simulations identified breath VOC mass ions with greater than random diagnostic accuracy for lung cancer, and these were combined in a multivariate predictive algorithm. Model-testing phase (blinded validation): We analyzed breath VOCs in an independent cohort of similar subjects (n = 70, 51, 75 and 19 respectively). The algorithm predicted discriminant function (DF) values in blinded replicate breath VOC samples analyzed independently at two laboratories (A and B). Outcome modeling: We modeled the expected effects of combining breath biomarkers with chest CT on the sensitivity and specificity of lung cancer screening. Results Unblinded model-building phase. The algorithm identified lung cancer with sensitivity 74.0%, specificity 70.7% and C-statistic 0.78. Blinded model-testing phase: The algorithm identified lung cancer at Laboratory A with sensitivity 68.0%, specificity 68.4%, C-statistic 0.71; and at Laboratory B with sensitivity 70.1%, specificity 68.0%, C-statistic 0.70, with linear correlation between replicates (r = 0.88). In a projected outcome model, breath biomarkers increased the sensitivity, specificity, and positive and negative predictive values of chest CT for lung cancer when the tests were combined in series or parallel. Conclusions Breath VOC mass ion biomarkers identified lung cancer in a separate independent cohort, in a blinded replicated study. Combining breath biomarkers with chest CT could potentially improve the sensitivity and specificity of lung cancer screening. Trial Registration ClinicalTrials.gov NCT00639067 PMID:26698306

  9. Sleep-Disordered Breathing and Mortality: A Prospective Cohort Study

    PubMed Central

    Punjabi, Naresh M.; Caffo, Brian S.; Goodwin, James L.; Gottlieb, Daniel J.; Newman, Anne B.; O'Connor, George T.; Rapoport, David M.; Redline, Susan; Resnick, Helaine E.; Robbins, John A.; Shahar, Eyal; Unruh, Mark L.; Samet, Jonathan M.

    2009-01-01

    Background Sleep-disordered breathing is a common condition associated with adverse health outcomes including hypertension and cardiovascular disease. The overall objective of this study was to determine whether sleep-disordered breathing and its sequelae of intermittent hypoxemia and recurrent arousals are associated with mortality in a community sample of adults aged 40 years or older. Methods and Findings We prospectively examined whether sleep-disordered breathing was associated with an increased risk of death from any cause in 6,441 men and women participating in the Sleep Heart Health Study. Sleep-disordered breathing was assessed with the apnea–hypopnea index (AHI) based on an in-home polysomnogram. Survival analysis and proportional hazards regression models were used to calculate hazard ratios for mortality after adjusting for age, sex, race, smoking status, body mass index, and prevalent medical conditions. The average follow-up period for the cohort was 8.2 y during which 1,047 participants (587 men and 460 women) died. Compared to those without sleep-disordered breathing (AHI: <5 events/h), the fully adjusted hazard ratios for all-cause mortality in those with mild (AHI: 5.0–14.9 events/h), moderate (AHI: 15.0–29.9 events/h), and severe (AHI: ≥30.0 events/h) sleep-disordered breathing were 0.93 (95% CI: 0.80–1.08), 1.17 (95% CI: 0.97–1.42), and 1.46 (95% CI: 1.14–1.86), respectively. Stratified analyses by sex and age showed that the increased risk of death associated with severe sleep-disordered breathing was statistically significant in men aged 40–70 y (hazard ratio: 2.09; 95% CI: 1.31–3.33). Measures of sleep-related intermittent hypoxemia, but not sleep fragmentation, were independently associated with all-cause mortality. Coronary artery disease–related mortality associated with sleep-disordered breathing showed a pattern of association similar to all-cause mortality. Conclusions Sleep-disordered breathing is associated with all-cause mortality and specifically that due to coronary artery disease, particularly in men aged 40–70 y with severe sleep-disordered breathing. Please see later in the article for the Editors' Summary PMID:19688045

  10. Clinical breath analysis: Discriminating between human endogenous compounds and exogenous (environmental) chemical confounders

    EPA Science Inventory

    Volatile organic compounds (VOCs) in exhaled breath originate from current or previous environmental exposures (exogenous compounds) and internal metabolic anabolic and catabolic) production (endogenous compounds). The origins of certain VOCs in breath presumed to be endogenous ...

  11. Meeting Reports for 2013: Recent Advances in Breath Biomarker Research

    EPA Science Inventory

    This article reports the efforts of the breath research community affiliated with the International Association of Breath Research (IABR) in disseminating research results in high profile technical meetings in the United States (US). Specifically, we describe presentations at a ...

  12. Air sampling unit for breath analyzers

    NASA Astrophysics Data System (ADS)

    Szabra, Dariusz; Prokopiuk, Artur; Mikołajczyk, Janusz; Ligor, Tomasz; Buszewski, Bogusław; Bielecki, Zbigniew

    2017-11-01

    The paper presents a portable breath sampling unit (BSU) for human breath analyzers. The developed unit can be used to probe air from the upper airway and alveolar for clinical and science studies. The BSU is able to operate as a patient interface device for most types of breath analyzers. Its main task is to separate and to collect the selected phases of the exhaled air. To monitor the so-called I, II, or III phase and to identify the airflow from the upper and lower parts of the human respiratory system, the unit performs measurements of the exhaled CO2 (ECO2) in the concentration range of 0%-20% (0-150 mm Hg). It can work in both on-line and off-line modes according to American Thoracic Society/European Respiratory Society standards. A Tedlar bag with a volume of 5 dm3 is mounted as a BSU sample container. This volume allows us to collect ca. 1-25 selected breath phases. At the user panel, each step of the unit operation is visualized by LED indicators. This helps us to regulate the natural breathing cycle of the patient. There is also an operator's panel to ensure monitoring and configuration setup of the unit parameters. The operation of the breath sampling unit was preliminarily verified using the gas chromatography/mass spectrometry (GC/MS) laboratory setup. At this setup, volatile organic compounds were extracted by solid phase microextraction. The tests were performed by the comparison of GC/MS signals from both exhaled nitric oxide and isoprene analyses for three breath phases. The functionality of the unit was proven because there was an observed increase in the signal level in the case of the III phase (approximately 40%). The described work made it possible to construct a prototype of a very efficient breath sampling unit dedicated to breath sample analyzers.

  13. Micropreconcentrator in LTCC Technology with Mass Spectrometry for the Detection of Acetone in Healthy and Type-1 Diabetes Mellitus Patient Breath

    PubMed Central

    Rydosz, Artur

    2014-01-01

    Breath analysis has long been recognized as a potentially attractive method for the diagnosis of several diseases. The main advantage over other diagnostic methods such as blood or urine analysis is that breath analysis is fully non-invasive, comfortable for patients and breath samples can be easily obtained. One possible future application of breath analysis may be the diagnosing and monitoring of diabetes. It is, therefore, essential, to firstly determine a relationship between exhaled biomarker concentration and glucose in blood as well as to compare the results with the results obtained from non-diabetic subjects. Concentrations of molecules which are biomarkers of diseases’ states, or early indicators of disease should be well documented, i.e., the variations of abnormal concentrations of breath biomarkers with age, gender and ethnic issues need to be verified. Furthermore, based on performed measurements it is rather obvious that analysis of exhaled acetone as a single biomarker of diabetes is unrealistic. In this paper, the author presents results of his research conducted on samples of breath gas from eleven healthy volunteers (HV) and fourteen type-1 diabetic patients (T1DM) which were collected in 1-l SKC breath bags. The exhaled acetone concentration was measured using mass spectrometry (HPR-20 QIC, Hiden Analytical, Warrington, UK) coupled with a micropreconcentrator in LTCC (Low Temperature Cofired Ceramic). However, as according to recent studies the level of acetone varies to a significant extent for each blood glucose concentration of single individuals, a direct and absolute relationship between blood glucose and acetone has not been proved. Nevertheless, basing on the research results acetone in diabetic breath was found to be higher than 1.11 ppmv, while its average concentration in normal breath was lower than 0.83 ppmv. PMID:25310087

  14. Mask Ventilation during Induction of General Anesthesia: Influences of Obstructive Sleep Apnea.

    PubMed

    Sato, Shin; Hasegawa, Makoto; Okuyama, Megumi; Okazaki, Junko; Kitamura, Yuji; Sato, Yumi; Ishikawa, Teruhiko; Sato, Yasunori; Isono, Shiroh

    2017-01-01

    Depending on upper airway patency during anesthesia induction, tidal volume achieved by mask ventilation may vary. In 80 adult patients undergoing general anesthesia, the authors tested a hypothesis that tidal volume during mask ventilation is smaller in patients with sleep-disordered breathing priorly defined as apnea hypopnea index greater than 5 per hour. One-hand mask ventilation with a constant ventilator setting (pressure-controlled ventilation) was started 20 s after injection of rocuronium and maintained for 1 min during anesthesia induction. Mask ventilation efficiency was assessed by the breath number needed to initially exceed 5 ml/kg ideal body weight of expiratory tidal volume (primary outcome) and tidal volumes (secondary outcomes) during initial 15 breaths (UMIN000012494). Tidal volume progressively increased by more than 70% in 1 min and did not differ between sleep-disordered breathing (n = 42) and non-sleep-disordered breathing (n = 38) patients. In post hoc subgroup analyses, the primary outcome breath number (mean [95% CI], 5.7 [4.1 to 7.3] vs. 1.7 [0.2 to 3.2] breath; P = 0.001) and mean tidal volume (6.5 [4.6 to 8.3] vs. 9.6 [7.7 to 11.4] ml/kg ideal body weight; P = 0.032) were significantly smaller in 20 sleep-disordered breathing patients with higher apnea hypopnea index (median [25th to 75th percentile]: 21.7 [17.6 to 31] per hour) than in 20 non-sleep disordered breathing subjects with lower apnea hypopnea index (1.0 [0.3 to 1.5] per hour). Obesity and occurrence of expiratory flow limitation during one-hand mask ventilation independently explained the reduction of efficiency of mask ventilation, while the use of two hands effectively normalized inefficient mask ventilation during one-hand mask ventilation. One-hand mask ventilation is difficult in patients with obesity and severe sleep-disordered breathing particularly when expiratory flow limitation occurs during mask ventilation.

  15. Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system.

    PubMed

    Mageras, G S; Yorke, E; Rosenzweig, K; Braban, L; Keatley, E; Ford, E; Leibel, S A; Ling, C C

    2001-01-01

    We report on initial patient studies to evaluate the performance of a commercial respiratory gating radiotherapy system. The system uses a breathing monitor, consisting of a video camera and passive infrared reflective markers placed on the patient's thorax, to synchronize radiation from a linear accelerator with the patient's breathing cycle. Six patients receiving treatment for lung cancer participated in a study of system characteristics during treatment simulation with fluoroscopy. Breathing synchronized fluoroscopy was performed initially without instruction, followed by fluoroscopy with recorded verbal instruction (i.e., when to inhale and exhale) with the tempo matched to the patient's normal breathing period. Patients tended to inhale more consistently when given instruction, as assessed by an external marker movement. This resulted in smaller variation in expiration and inspiration marker positions relative to total excursion, thereby permitting more precise gating tolerances at those parts of the breathing cycle. Breathing instruction also reduced the fraction of session times having irregular breathing as measured by the system software, thereby potentially increasing the accelerator duty factor and decreasing treatment times. Fluoroscopy studies showed external monitor movement to correlate well with that of the diaphragm in four patients, whereas time delays of up to 0.7 s in diaphragm movement were observed in two patients with impaired lung function. From fluoroscopic observations, average patient diaphragm excursion was reduced from 1.4 cm (range 0.7-2.1 cm) without gating and without breathing instruction, to 0.3 cm (range 0.2-0.5 cm) with instruction and with gating tolerances set for treatment at expiration for 25% of the breathing cycle. Patients expressed no difficulty with following instruction for the duration of a session. We conclude that the external monitor accurately predicts internal respiratory motion in most cases; however, it may be important to check with fluoroscopy for possible time delays in patients with impaired lung function. Furthermore, we observe that verbal instruction can improve breathing regularity, thus improving the performance of gated treatments with this system.

  16. Deep breathing exercises with positive expiratory pressure at a higher rate improve oxygenation in the early period after cardiac surgery--a randomised controlled trial.

    PubMed

    Urell, Charlotte; Emtner, Margareta; Hedenström, Hans; Tenling, Arne; Breidenskog, Marie; Westerdahl, Elisabeth

    2011-07-01

    In addition to early mobilisation, a variety of breathing exercises are used to prevent postoperative pulmonary complications after cardiac surgery. The optimal duration of the treatment is not well evaluated. The aim of this study was to determine the effect of 30 versus 10 deep breaths hourly, while awake, with positive expiratory pressure on oxygenation and pulmonary function the first days after cardiac surgery. A total of 181 patients, undergoing cardiac surgery, were randomised into a treatment group, performing 30 deep breaths hourly the first postoperative days, or into a control group performing 10 deep breaths hourly. The main outcome measurement arterial blood gases and the secondary outcome pulmonary function, evaluated with spirometry, were determined on the second postoperative day. Preoperatively, both study groups were similar in terms of age, SpO(2), forced expiratory volume in 1s and New York Heart Association classification. On the second postoperative day, arterial oxygen tension (PaO(2)) was 8.9 ± 1.7 kPa in the treatment group and 8.1 ± 1.4 kPa in the control group (p = 0.004). Arterial oxygen saturation (SaO(2)) was 92.7 ± 3.7% in the treatment group and 91.1 ± 3.8% in the control group (p = 0.016). There were no differences in measured lung function between the groups or in compliance to the breathing exercises. Compliance was 65% of possible breathing sessions. A significantly increased oxygenation was found in patients performing 30 deep breaths the first two postoperative days compared with control patients performing 10 deep breaths hourly. These results support the implementation of a higher rate of deep breathing exercises in the initial phase after cardiac surgery. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  17. Voluntary suppression of hyperthermia-induced hyperventilation mitigates the reduction in cerebral blood flow velocity during exercise in the heat.

    PubMed

    Tsuji, Bun; Honda, Yasushi; Ikebe, Yusuke; Fujii, Naoto; Kondo, Narihiko; Nishiyasu, Takeshi

    2015-04-15

    Hyperthermia during prolonged exercise leads to hyperventilation, which can reduce arterial CO2 pressure (PaCO2 ) and, in turn, cerebral blood flow (CBF) and thermoregulatory response. We investigated 1) whether humans can voluntarily suppress hyperthermic hyperventilation during prolonged exercise and 2) the effects of voluntary breathing control on PaCO2 , CBF, sweating, and skin blood flow. Twelve male subjects performed two exercise trials at 50% of peak oxygen uptake in the heat (37°C, 50% relative humidity) for up to 60 min. Throughout the exercise, subjects breathed normally (normal-breathing trial) or they tried to control their minute ventilation (respiratory frequency was timed with a metronome, and target tidal volumes were displayed on a monitor) to the level reached after 5 min of exercise (controlled-breathing trial). Plotting ventilatory and cerebrovascular responses against esophageal temperature (Tes) showed that minute ventilation increased linearly with rising Tes during normal breathing, whereas controlled breathing attenuated the increased ventilation (increase in minute ventilation from the onset of controlled breathing: 7.4 vs. 1.6 l/min at +1.1°C Tes; P < 0.001). Normal breathing led to decreases in estimated PaCO2 and middle cerebral artery blood flow velocity (MCAV) with rising Tes, but controlled breathing attenuated those reductions (estimated PaCO2 -3.4 vs. -0.8 mmHg; MCAV -10.4 vs. -3.9 cm/s at +1.1°C Tes; P = 0.002 and 0.011, respectively). Controlled breathing had no significant effect on chest sweating or forearm vascular conductance (P = 0.67 and 0.91, respectively). Our results indicate that humans can voluntarily suppress hyperthermic hyperventilation during prolonged exercise, and this suppression mitigates changes in PaCO2 and CBF. Copyright © 2015 the American Physiological Society.

  18. Effectiveness of different rescanning techniques for scanned proton radiotherapy in lung cancer patients

    NASA Astrophysics Data System (ADS)

    Engwall, E.; Glimelius, L.; Hynning, E.

    2018-05-01

    Non-small cell lung cancer (NSCLC) is a tumour type thought to be well-suited for proton radiotherapy. However, the lung region poses many problems related to organ motion and can for actively scanned beams induce severe interplay effects. In this study we investigate four mitigating rescanning techniques: (1) volumetric rescanning, (2) layered rescanning, (3) breath-sampled (BS) layered rescanning, and (4) continuous breath-sampled (CBS) layered rescanning. The breath-sampled methods will spread the layer rescans over a full breathing cycle, resulting in an improved averaging effect at the expense of longer treatment times. In CBS, we aim at further improving the averaging by delivering as many rescans as possible within one breathing cycle. The interplay effect was evaluated for 4D robustly optimized treatment plans (with and without rescanning) for seven NSCLC patients in the treatment planning system RayStation. The optimization and final dose calculation used a Monte Carlo dose engine to account for the density heterogeneities in the lung region. A realistic treatment delivery time structure given from the IBA ScanAlgo simulation tool served as basis for the interplay evaluation. Both slow (2.0 s) and fast (0.1 s) energy switching times were simulated. For all seven studied patients, rescanning improves the dose conformity to the target. The general trend is that the breath-sampled techniques are superior to layered and volumetric rescanning with respect to both target coverage and variability in dose to OARs. The spacing between rescans in our breath-sampled techniques is set at planning, based on the average breathing cycle length obtained in conjunction with CT acquisition. For moderately varied breathing cycle lengths between planning and delivery (up to 15%), the breath-sampled techniques still mitigate the interplay effect well. This shows the potential for smooth implementation at the clinic without additional motion monitoring equipment.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conroy, L; Quirk, S; Smith, WL

    Purpose: We used Real-Time Position Management (RPM) to evaluate breath hold amplitude and variability when gating with a visually monitored deep inspiration breath hold technique (VM-DIBH) with retrospective cine image chest wall position verification. Methods: Ten patients with left-sided breast cancer were treated using VM-DIBH. Respiratory motion was passively collected once weekly using RPM with the marker block positioned at the xiphoid process. Cine images on the tangent medial field were acquired on fractions with RPM monitoring for retrospective verification of chest wall position during breath hold. The amplitude and duration of all breath holds on which treatment beams weremore » delivered were extracted from the RPM traces. Breath hold position coverage was evaluated for symmetric RPM gating windows from ± 1 to 5 mm centered on the average breath hold amplitude of the first measured fraction as a baseline. Results: The average (range) breath hold amplitude and duration was 18 mm (3–36 mm) and 19 s (7–34 s). The average (range) of amplitude standard deviation per patient over all breath holds was 2.7 mm (1.2–5.7 mm). With the largest allowable RPM gating window (± 5 mm), 4 of 10 VM-DIBH patients would have had ≥ 10% of their breath hold positions excluded by RPM. Cine verification of the chest wall position during the medial tangent field showed that the chest wall was greater than 5 mm from the baseline in only 1 out of 4 excluded patients. Cine images verify the chest wall/breast position only, whether this variation is acceptable in terms of heart sparing is a subject of future investigation. Conclusion: VM-DIBH allows for greater breath hold amplitude variability than using a 5 mm gating window with RPM, while maintaining chest wall positioning accuracy within 5 mm for the majority of patients.« less

  20. G protection: interaction of straining maneuvers and positive pressure breathing.

    PubMed

    Eiken, Ola; Kölegärd, Roger; Bergsten, Eddie; Grönkvist, Mikael

    2007-04-01

    G protection in the 39 Gripen aircraft is provided by a full coverage anti-G suit, a pressure-breathing system, and anti-G straining maneuvers (AGSM). The purpose was to study (1) the interaction of pressure breathing and AGSM while wearing an anti-G suit; and (2) the G-protective properties of the anti-G suit alone and in combination with the pressure-breathing system. During rapid onset rate G-time profiles (< or =9 G), 10 subjects were investigated in 5 conditions: (I) sitting relaxed, without any G-protective garment; (II) sitting relaxed and wearing an anti-G suit; (III) sitting relaxed, wearing an anti-G suit, and pressure breathing; IV) wearing an anti-G suit and performing AGSM; and V) wearing an anti-G suit, pressure breathing, and performing AGSM. In supplementary experiments (n=9), the share of the anti-G suit protection afforded by the abdominal bladder was investigated. G tolerance was 3.4 Gz (range: 2.8-4.3) in condition I, > or = 6.5 Gz (4.5-9.0) in II, > or = 8.0 Gz (6.5-9.0) in III, > or = 8.9 Gz (8.5-9.0) in IV and > or = 9.0 Gz (8.5-9.0) in V. In the supplementary experiments, the anti-G suit afforded a 2.8-G protection, a third of which was contributed by the abdominal bladder. In the relaxed state, pressure applied to the airways was transmitted undistorted to the intrathoracic space. During AGSM, intrathoracic pressure rose to 10-14 kPa, regardless of whether AGSM was performed with or without pressure breathing. The anti-G suit and the pressure breathing system provide G protection of > or = 4.6 G, of which the anti-G suit contributes about 3.0 G. The C-protective properties of the anti-G suit and those of pressure breathing appears to be additive, whereas the G protection afforded by pressure breathing does not add to that provided by AGSM.

  1. A prospective gating method to acquire a diverse set of free-breathing CT images for model-based 4DCT

    NASA Astrophysics Data System (ADS)

    O'Connell, D.; Ruan, D.; Thomas, D. H.; Dou, T. H.; Lewis, J. H.; Santhanam, A.; Lee, P.; Low, D. A.

    2018-02-01

    Breathing motion modeling requires observation of tissues at sufficiently distinct respiratory states for proper 4D characterization. This work proposes a method to improve sampling of the breathing cycle with limited imaging dose. We designed and tested a prospective free-breathing acquisition protocol with a simulation using datasets from five patients imaged with a model-based 4DCT technique. Each dataset contained 25 free-breathing fast helical CT scans with simultaneous breathing surrogate measurements. Tissue displacements were measured using deformable image registration. A correspondence model related tissue displacement to the surrogate. Model residual was computed by comparing predicted displacements to image registration results. To determine a stopping criteria for the prospective protocol, i.e. when the breathing cycle had been sufficiently sampled, subsets of N scans where 5  ⩽  N  ⩽  9 were used to fit reduced models for each patient. A previously published metric was employed to describe the phase coverage, or ‘spread’, of the respiratory trajectories of each subset. Minimum phase coverage necessary to achieve mean model residual within 0.5 mm of the full 25-scan model was determined and used as the stopping criteria. Using the patient breathing traces, a prospective acquisition protocol was simulated. In all patients, phase coverage greater than the threshold necessary for model accuracy within 0.5 mm of the 25 scan model was achieved in six or fewer scans. The prospectively selected respiratory trajectories ranked in the (97.5  ±  4.2)th percentile among subsets of the originally sampled scans on average. Simulation results suggest that the proposed prospective method provides an effective means to sample the breathing cycle with limited free-breathing scans. One application of the method is to reduce the imaging dose of a previously published model-based 4DCT protocol to 25% of its original value while achieving mean model residual within 0.5 mm.

  2. A Novel Fast Helical 4D-CT Acquisition Technique to Generate Low-Noise Sorting Artifact–Free Images at User-Selected Breathing Phases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, David, E-mail: dhthomas@mednet.ucla.edu; Lamb, James; White, Benjamin

    2014-05-01

    Purpose: To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Methods and Materials: Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. Themore » tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Results: Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. Conclusions: The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact–free images at a patient dose similar to or less than current 4D-CT techniques.« less

  3. Improved ROS defense in the swimbladder of a facultative air-breathing erythrinid fish, jeju, compared to a non-air-breathing close relative, traira.

    PubMed

    Pelster, Bernd; Giacomin, Marina; Wood, Chris M; Val, Adalberto L

    2016-07-01

    The jeju Hoplerythrinus unitaeniatus and the traira Hoplias malabaricus are two closely related erythrinid fish, both possessing a two-chambered physostomous swimbladder. In the jeju the anterior section of the posterior bladder is highly vascularized and the swimbladder is used for aerial respiration; the traira, in turn, is a water-breather that uses the swimbladder as a buoyancy organ and not for aerial oxygen uptake. Observation of the breathing behavior under different levels of water oxygenation revealed that the traira started aquatic surface respiration only under severe hypoxic conditions and did not breathe air. In the jeju air-breathing behavior was observed under normoxic conditions, and the frequency of air-breathing was significantly increased under hypoxic conditions. Unexpectedly, even under hyperoxic conditions (30 mg O2 L(-1)) the jeju continued to take air breaths, and compared with normoxic conditions the frequency was not reduced. Because the frequently air-exposed swimbladder tissue faces higher oxygen partial pressures than normally experienced by other fish tissues, it was hypothesized that in the facultative air-breathing jeju, swimbladder tissue would have a higher antioxidative capacity than the swimbladder tissue of the water breathing traira. Measurement of total glutathione (GSSG/GSH) concentration in anterior and posterior swimbladder tissue revealed a higher concentration of this antioxidant in swimbladder tissue as compared to muscle tissue in the jeju. Furthermore, the GSSG/GSH concentration in jeju tissues was significantly higher than in traira tissues. Similarly, activities of enzymes involved in the breakdown of reactive oxygen species were significantly higher in the jeju swimbladder as compared to the traira swimbladder. The results show that the jeju, using the swimbladder as an additional breathing organ, has an enhanced antioxidative capacity in the swimbladder as compared to the traira, using the swimbladder only as a buoyancy organ.

  4. Voluntary suppression of hyperthermia-induced hyperventilation mitigates the reduction in cerebral blood flow velocity during exercise in the heat

    PubMed Central

    Tsuji, Bun; Honda, Yasushi; Ikebe, Yusuke; Fujii, Naoto; Kondo, Narihiko

    2015-01-01

    Hyperthermia during prolonged exercise leads to hyperventilation, which can reduce arterial CO2 pressure (PaCO2) and, in turn, cerebral blood flow (CBF) and thermoregulatory response. We investigated 1) whether humans can voluntarily suppress hyperthermic hyperventilation during prolonged exercise and 2) the effects of voluntary breathing control on PaCO2, CBF, sweating, and skin blood flow. Twelve male subjects performed two exercise trials at 50% of peak oxygen uptake in the heat (37°C, 50% relative humidity) for up to 60 min. Throughout the exercise, subjects breathed normally (normal-breathing trial) or they tried to control their minute ventilation (respiratory frequency was timed with a metronome, and target tidal volumes were displayed on a monitor) to the level reached after 5 min of exercise (controlled-breathing trial). Plotting ventilatory and cerebrovascular responses against esophageal temperature (Tes) showed that minute ventilation increased linearly with rising Tes during normal breathing, whereas controlled breathing attenuated the increased ventilation (increase in minute ventilation from the onset of controlled breathing: 7.4 vs. 1.6 l/min at +1.1°C Tes; P < 0.001). Normal breathing led to decreases in estimated PaCO2 and middle cerebral artery blood flow velocity (MCAV) with rising Tes, but controlled breathing attenuated those reductions (estimated PaCO2 −3.4 vs. −0.8 mmHg; MCAV −10.4 vs. −3.9 cm/s at +1.1°C Tes; P = 0.002 and 0.011, respectively). Controlled breathing had no significant effect on chest sweating or forearm vascular conductance (P = 0.67 and 0.91, respectively). Our results indicate that humans can voluntarily suppress hyperthermic hyperventilation during prolonged exercise, and this suppression mitigates changes in PaCO2 and CBF. PMID:25632021

  5. A novel fast helical 4D-CT acquisition technique to generate low-noise sorting artifact-free images at user-selected breathing phases.

    PubMed

    Thomas, David; Lamb, James; White, Benjamin; Jani, Shyam; Gaudio, Sergio; Lee, Percy; Ruan, Dan; McNitt-Gray, Michael; Low, Daniel

    2014-05-01

    To develop a novel 4-dimensional computed tomography (4D-CT) technique that exploits standard fast helical acquisition, a simultaneous breathing surrogate measurement, deformable image registration, and a breathing motion model to remove sorting artifacts. Ten patients were imaged under free-breathing conditions 25 successive times in alternating directions with a 64-slice CT scanner using a low-dose fast helical protocol. An abdominal bellows was used as a breathing surrogate. Deformable registration was used to register the first image (defined as the reference image) to the subsequent 24 segmented images. Voxel-specific motion model parameters were determined using a breathing motion model. The tissue locations predicted by the motion model in the 25 images were compared against the deformably registered tissue locations, allowing a model prediction error to be evaluated. A low-noise image was created by averaging the 25 images deformed to the first image geometry, reducing statistical image noise by a factor of 5. The motion model was used to deform the low-noise reference image to any user-selected breathing phase. A voxel-specific correction was applied to correct the Hounsfield units for lung parenchyma density as a function of lung air filling. Images produced using the model at user-selected breathing phases did not suffer from sorting artifacts common to conventional 4D-CT protocols. The mean prediction error across all patients between the breathing motion model predictions and the measured lung tissue positions was determined to be 1.19 ± 0.37 mm. The proposed technique can be used as a clinical 4D-CT technique. It is robust in the presence of irregular breathing and allows the entire imaging dose to contribute to the resulting image quality, providing sorting artifact-free images at a patient dose similar to or less than current 4D-CT techniques. Copyright © 2014 Elsevier Inc. All rights reserved.

  6. Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell

    PubMed Central

    Iwata, Takuro; Katagiri, Takashi; Matsuura, Yuji

    2016-01-01

    A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that the developed system, using a laser-driven, high-intensity light source and a 3-m-long, aluminum-coated hollow optical fiber, could successfully measure nitric-oxide gas with a 50 ppb concentration. An absorption spectrum of a breath sample in the wavelength region of around 200–300 nm was measured, and the measured spectrum revealed the main absorbing components in breath as water vapor, isoprene, and ozone converted from oxygen by radiation of ultraviolet light. The concentration of isoprene in breath was estimated by multiple linear regression. The regression analysis results showed that the proposed analysis system enables real-time monitoring of isoprene during the exhaling of breath. Accordingly, it is suitable for measuring the circadian variation of isoprene. PMID:27929387

  7. Inflammatory Asthma Phenotype Discrimination Using an Electronic Nose Breath Analyzer.

    PubMed

    Plaza, V; Crespo, A; Giner, J; Merino, J L; Ramos-Barbón, D; Mateus, E F; Torrego, A; Cosio, B G; Agustí, A; Sibila, O

    2015-01-01

    Patients with persistent asthma have different inflammatory phenotypes. The electronic nose is a new technology capable of distinguishing volatile organic compound (VOC) breath-prints in exhaled breath. The aim of the study was to investigate the capacity of electronic nose breath-print analysis to discriminate between different inflammatory asthma phenotypes (eosinophilic, neutrophilic, paucigranulocytic) determined by induced sputum in patients with persistent asthma. Fifty-two patients with persistent asthma were consecutively included in a cross-sectional proof-of-concept study. Inflammatory asthma phenotypes (eosinophilic, neutrophilic and paucigranulocytic) were recognized by inflammatory cell counts in induced sputum. VOC breath-prints were analyzed using the electronic nose Cyranose 320 and assessed by discriminant analysis on principal component reduction, resulting in cross-validated accuracy values. Receiver operating characteristic (ROC) curves were calculated. VOC breath-prints were different in eosinophilic asthmatics compared with both neutrophilic asthmatics (accuracy 73%; P=.008; area under ROC, 0.92) and paucigranulocytic asthmatics (accuracy 74%; P=.004; area under ROC, 0.79). Likewise, neutrophilic and paucigranulocytic breath-prints were also different (accuracy 89%; P=.001; area under ROC, 0.88). An electronic nose can discriminate inflammatory phenotypes in patients with persistent asthma in a regular clinical setting. ClinicalTrials.gov identifier: NCT02026336.

  8. Cardiac Repolarization Changes in the Children with Breath-Holding Spells

    PubMed Central

    Amoozgar, Hamid; Saleh, Fazl; Farhani, Nahal; Rafiei, Mohammad; Inaloo, Soroor; Asadipooya, Ali-Akbar

    2013-01-01

    Objective Breath-holding spells are known as benign attacks, frequencies of which decrease by the development of the autonomic nervous system. The present study aims to compare the electrocardiographic repolarization in children with breath-holding spells. Methods In this study, QT dispersion, QTc dispersion, T peak to T end dispersion, and P wave dispersion of the twelve-lead surface electrocardiography of fifty children who had breath-holding spells were measured and compared with normal children from April 2011 to August 2012. Findings Forty-four (88%) patients had cyanotic spells, while 6 (12%) had pallid spells. QTc dispersion was increased in the patients with breath-holding spells (148.2±33.1) compared to the healthy children (132±27.3) and the difference was statically significant (P = 0.01). Meanwhile, no statistically significant differences were observed between the patients and the control subjects regarding the other parameters (P > 0.05). Conclusion QTc dispersion was significantly increased in the patients with breath-holding spells compared to normal children and this is a sign of cardiac repolarization abnormality as well as the increased risk of cardiac arrhythmia in patients with breath-holding spells. PMID:24910749

  9. The immediate effects of deep breathing exercises on atelectasis and oxygenation after cardiac surgery.

    PubMed

    Westerdahl, Elisabeth; Lindmark, Birgitta; Eriksson, Tomas; Hedenstierna, Göran; Tenling, Arne

    2003-12-01

    Objective--To investigate the effects of deep breathing performed on the second postoperative day after coronary artery bypass graft surgery. Design--The immediate effects of 30 deep breaths performed without a mechanical device (n = 21), with a blow bottle device (n = 20) and with an inspiratory resistance-positive expiratory pressure mask (n = 20) were studied. Spiral computed tomography and arterial blood gas analyses were performed immediately before and after the intervention. Results--Deep breathing caused a significant decrease in atelectatic area from 12.3 +/- 7.3% to 10.2 +/- 6.7% (p < 0.0001) of total lung area 1 cm above the diaphragm and from 3.9 +/- 3.5% to 3.3 +/- 3.1% (p < 0.05) 5 cm above the diaphragm. No difference between the breathing techniques was found. The aerated lung area increased by 5% (p < 0.001). The PaO (2) increased by 0.2 kPa (p < 0.05), while PaCO (2) was unchanged in the three groups. Conclusion--A significant decrease of atelectatic area, increase in aerated lung area and a small increase in PaO (2) were found after performance of 30 deep breaths. No difference between the three breathing techniques was found.

  10. Tracking performance with two breathing oxygen concentrations after high altitude rapid decompression

    NASA Technical Reports Server (NTRS)

    Nesthus, Thomas E.; Schiflett, Samuel G.; Oakley, Carolyn J.

    1992-01-01

    Current military aircraft Liquid Oxygen (LOX) systems supply 99.5 pct. gaseous Aviator's Breathing Oxygen (ABO) to aircrew. Newer Molecular Sieve Oxygen Generation Systems (MSOGS) supply breathing gas concentration of 93 to 95 pct. O2. The margin is compared of hypoxia protection afforded by ABO and MSOGS breathing gas after a 5 psi differential rapid decompression (RD) in a hypobaric research chamber. The barometric pressures equivalent to the altitudes of 46000, 52000, 56000, and 60000 ft were achieved from respective base altitudes in 1 to 1.5 s decompressions. During each exposure, subjects remained at the simulated peak altitude breathing either 100 or 94 pct. O2 with positive pressure for 60 s, followed by a rapid descent to 40000 ft. Subjects used the Tactical Life Support System (TLSS) for high altitude protection. Subcritical tracking task performance on the Performance Evaluation Device (PED) provided psychomotor test measures. Overall tracking task performance results showed no differences between the MSOGS breathing O2 concentration of 94 pct. and ABO. Significance RMS error differences were found between the ground level and base altitude trials compared to peak altitude trials. The high positive breathing pressures occurring at the peak altitudes explained the differences.

  11. A quantitative evaluation of spurious results in the infrared spectroscopic measurement of CO2 isotope ratios

    NASA Astrophysics Data System (ADS)

    Mansfield, C. D.; Rutt, H. N.

    2002-02-01

    The possible generation of spurious results, arising from the application of infrared spectroscopic techniques to the measurement of carbon isotope ratios in breath, due to coincident absorption bands has been re-examined. An earlier investigation, which approached the problem qualitatively, fulfilled its aspirations in providing an unambiguous assurance that 13C16O2/12C16O2 ratios can be confidently measured for isotopic breath tests using instruments based on infrared absorption. Although this conclusion still stands, subsequent quantitative investigation has revealed an important exception that necessitates a strict adherence to sample collection protocol. The results show that concentrations and decay rates of the coincident breath trace compounds acetonitrile and carbon monoxide, found in the breath sample of a heavy smoker, can produce spurious results. Hence, findings from this investigation justify the concern that breath trace compounds present a risk to the accurate measurement of carbon isotope ratios in breath when using broadband, non-dispersive, ground state absorption infrared spectroscopy. It provides recommendations on the length of smoking abstention required to avoid generation of spurious results and also reaffirms, through quantitative argument, the validity of using infrared absorption spectroscopy to measure CO2 isotope ratios in breath.

  12. Effects of Slow Deep Breathing at High Altitude on Oxygen Saturation, Pulmonary and Systemic Hemodynamics

    PubMed Central

    Bilo, Grzegorz; Revera, Miriam; Bussotti, Maurizio; Bonacina, Daniele; Styczkiewicz, Katarzyna; Caldara, Gianluca; Giglio, Alessia; Faini, Andrea; Giuliano, Andrea; Lombardi, Carolina; Kawecka-Jaszcz, Kalina; Mancia, Giuseppe; Agostoni, Piergiuseppe; Parati, Gianfranco

    2012-01-01

    Slow deep breathing improves blood oxygenation (SpO2) and affects hemodynamics in hypoxic patients. We investigated the ventilatory and hemodynamic effects of slow deep breathing in normal subjects at high altitude. We collected data in healthy lowlanders staying either at 4559 m for 2–3 days (Study A; N = 39) or at 5400 m for 12–16 days (Study B; N = 28). Study variables, including SpO2 and systemic and pulmonary arterial pressure, were assessed before, during and after 15 minutes of breathing at 6 breaths/min. At the end of slow breathing, an increase in SpO2 (Study A: from 80.2±7.7% to 89.5±8.2%; Study B: from 81.0±4.2% to 88.6±4.5; both p<0.001) and significant reductions in systemic and pulmonary arterial pressure occurred. This was associated with increased tidal volume and no changes in minute ventilation or pulmonary CO diffusion. Slow deep breathing improves ventilation efficiency for oxygen as shown by blood oxygenation increase, and it reduces systemic and pulmonary blood pressure at high altitude but does not change pulmonary gas diffusion. PMID:23152851

  13. Effects of slow deep breathing at high altitude on oxygen saturation, pulmonary and systemic hemodynamics.

    PubMed

    Bilo, Grzegorz; Revera, Miriam; Bussotti, Maurizio; Bonacina, Daniele; Styczkiewicz, Katarzyna; Caldara, Gianluca; Giglio, Alessia; Faini, Andrea; Giuliano, Andrea; Lombardi, Carolina; Kawecka-Jaszcz, Kalina; Mancia, Giuseppe; Agostoni, Piergiuseppe; Parati, Gianfranco

    2012-01-01

    Slow deep breathing improves blood oxygenation (Sp(O2)) and affects hemodynamics in hypoxic patients. We investigated the ventilatory and hemodynamic effects of slow deep breathing in normal subjects at high altitude. We collected data in healthy lowlanders staying either at 4559 m for 2-3 days (Study A; N = 39) or at 5400 m for 12-16 days (Study B; N = 28). Study variables, including Sp(O2) and systemic and pulmonary arterial pressure, were assessed before, during and after 15 minutes of breathing at 6 breaths/min. At the end of slow breathing, an increase in Sp(O2) (Study A: from 80.2±7.7% to 89.5±8.2%; Study B: from 81.0±4.2% to 88.6±4.5; both p<0.001) and significant reductions in systemic and pulmonary arterial pressure occurred. This was associated with increased tidal volume and no changes in minute ventilation or pulmonary CO diffusion. Slow deep breathing improves ventilation efficiency for oxygen as shown by blood oxygenation increase, and it reduces systemic and pulmonary blood pressure at high altitude but does not change pulmonary gas diffusion.

  14. Optoacoustic 13C-breath test analyzer

    NASA Astrophysics Data System (ADS)

    Harde, Hermann; Helmrich, Günther; Wolff, Marcus

    2010-02-01

    The composition and concentration of exhaled volatile gases reflects the physical ability of a patient. Therefore, a breath analysis allows to recognize an infectious disease in an organ or even to identify a tumor. One of the most prominent breath tests is the 13C-urea-breath test, applied to ascertain the presence of the bacterium helicobacter pylori in the stomach wall as an indication of a gastric ulcer. In this contribution we present a new optical analyzer that employs a compact and simple set-up based on photoacoustic spectroscopy. It consists of two identical photoacoustic cells containing two breath samples, one taken before and one after capturing an isotope-marked substrate, where the most common isotope 12C is replaced to a large extent by 13C. The analyzer measures simultaneously the relative CO2 isotopologue concentrations in both samples by exciting the molecules on specially selected absorption lines with a semiconductor laser operating at a wavelength of 2.744 μm. For a reliable diagnosis changes of the 13CO2 concentration of 1% in the exhaled breath have to be detected at a concentration level of this isotope in the breath of about 500 ppm.

  15. Real-Time Analysis of Isoprene in Breath by Using Ultraviolet-Absorption Spectroscopy with a Hollow Optical Fiber Gas Cell.

    PubMed

    Iwata, Takuro; Katagiri, Takashi; Matsuura, Yuji

    2016-12-05

    A breath analysis system based on ultraviolet-absorption spectroscopy was developed by using a hollow optical fiber as a gas cell for real-time monitoring of isoprene in breath. The hollow optical fiber functions as an ultra-small-volume gas cell with a long path. The measurement sensitivity of the system was evaluated by using nitric-oxide gas as a gas sample. The evaluation result showed that the developed system, using a laser-driven, high-intensity light source and a 3-m-long, aluminum-coated hollow optical fiber, could successfully measure nitric-oxide gas with a 50 ppb concentration. An absorption spectrum of a breath sample in the wavelength region of around 200-300 nm was measured, and the measured spectrum revealed the main absorbing components in breath as water vapor, isoprene, and ozone converted from oxygen by radiation of ultraviolet light. The concentration of isoprene in breath was estimated by multiple linear regression. The regression analysis results showed that the proposed analysis system enables real-time monitoring of isoprene during the exhaling of breath. Accordingly, it is suitable for measuring the circadian variation of isoprene.

  16. Characterization of optical-surface-imaging-based spirometry for respiratory surrogating in radiotherapy

    PubMed Central

    Li, Guang; Huang, Hailiang; Chen, Qing; Gaebler, Carl P.; Lin, Tiffany; Yuan, Amy; Rimner, Andreas; Mechalakos, James

    2016-01-01

    Purpose: To provide a comprehensive characterization of a novel respiratory surrogate that uses optical surface imaging (OSI) for accurate tidal volume (TV) measurement, dynamic airflow (TV′) calculation, and quantitative breathing pattern (BP) estimation during free breathing (FB), belly breathing (BB), chest breathing (CB), and breath hold (BH). Methods: Optical surface imaging, which captures all respiration-induced torso surface motion, was applied to measure respiratory TV, TV′, and BP in three common breathing patterns. Eleven healthy volunteers participated in breathing experiments with concurrent OSI-based and conventional spirometric measurements under an institutional review board approved protocol. This OSI-based technique measures dynamic TV from torso volume change (ΔVtorso = TV) in reference to full exhalation and airflow (TV′ = dTV/dt). Volume conservation, excluding exchanging air, was applied for OSI-based measurements under negligible pleural pressure variation in FB, BB, and CB. To demonstrate volume conservation, a constant TV was measured during BH while the chest and belly are moving (“pretended” respiration). To assess the accuracy of OSI-based spirometry, a conventional spirometer was used as the standard for both TV and TV′. Using OSI, BP was measured as BPOSI = ΔVchest/ΔVtorso and BP can be visualized using BPSHI = SHIchest/(SHIchest + SHIbelly), where surface height index (SHI) is defined as the mean vertical distance within a region of interest on the torso surface. A software tool was developed for OSI image processing, volume calculation, and BP visualization, and another tool was implemented for data acquisition using a Bernoulli-type spirometer. Results: The accuracy of the OSI-based spirometry is −21 ± 33 cm3 or −3.5% ± 6.3% averaged from 11 volunteers with 76 ± 28 breathing cycles on average in FB. Breathing variations between two separate acquisitions with approximate 30-min intervals are substantial: −1% ± 34% (ranging from −64% to 40%) in TV, 4% ± 20% (ranging from −50% to 26%) in breathing period (T), and −1% ± 34% (ranging from −49% to 44%) in BP. The airflow accuracy and variation (between two exercises) are −1 ± 54 cm3/s and −5% ± 30%, respectively. The slope of linear regression between OSI–TV and spirometric TV is 0.93 (R2 = 0.95) for FB, 0.96 (R2 = 0.98) for BB, and 0.95 (R2 = 0.95) for CB. The correlation between the two spirometric measurements is 0.98 ± 0.01. BP increases from BB, FB to CB, while TV increases from FB, BB, to CB. Under BH, 4% volume variation (range) on average was observed. Conclusions: The OSI-based technique provides an accurate measurement of tidal volume, airflow rate, and breathing pattern; all affect internal organ motion. This technique can be applied to various breathing patterns, including FB, BB, and CB. Substantial breathing irregularities and irreproducibility were observed and quantified with the OSI-based technique. These breathing parameters are useful to quantify breathing conditions, which could be used for effective tumor motion predictions. PMID:26936719

  17. Breath measurement instrumentation as alcohol safety interlock systems

    DOT National Transportation Integrated Search

    1974-09-01

    This report describes the results of field tests of in-car instruments which measure alcohol on the driver's breath and prevent him from operating his vehicle if intoxicated. Two types of breath alcohol sensors were used for these tests; a fuel-cell ...

  18. Laboratory testing of two prototype in-vehicle breath test devices

    DOT National Transportation Integrated Search

    1985-08-01

    This report presents the results of laboratory testing of two recently developed prototype in-vehicle breath test devices. These devices are designed to prevent persons with alcohol on their breath from driving a car. The devices tested were the SOBE...

  19. EXHALED BREATH ANALYSIS FOR HUMAN EXPOSURE RESEARCH

    EPA Science Inventory

    Exhaled breath collection and analysis has historically been used in environmental research studies to characterize exposures to volatile organic compounds. The use of this approach is based on the fact that many compounds present in blood are reflected in the breath, and that...

  20. Rapid detection of nicotine from breath using desorption ionisation on porous silicon.

    PubMed

    Guinan, T M; Abdelmaksoud, H; Voelcker, N H

    2017-05-04

    Desorption ionisation on porous silicon (DIOS) was used for the detection of nicotine from exhaled breath. This result represents proof-of-principle of the ability of DIOS to detect small molecular analytes in breath including biomarkers and illicit drugs.

  1. NASA firefighters breathing system program report

    NASA Technical Reports Server (NTRS)

    Wood, W. B.

    1977-01-01

    Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

  2. A chlorate candle/lithium hydroxide personal breathing apparatus

    NASA Technical Reports Server (NTRS)

    Martin, F. E.

    1972-01-01

    A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.

  3. Real time chemical exposure and risk monitor

    DOEpatents

    Thrall, Karla D.; Kenny, Donald V.; Endres, George W. R.; Sisk, Daniel R.

    1997-01-01

    The apparatus of the present invention is a combination of a breath interface and an external exposure dosimeter interface to a chemical analysis device, all controlled by an electronic processor for quantitatively analyzing chemical analysis data from both the breath interface and the external exposure dosimeter for determining internal tissue dose. The method of the present invention is a combination of steps of measuring an external dose, measuring breath content, then analyzing the external dose and breath content and determining internal tissue dose.

  4. Real time chemical exposure and risk monitor

    DOEpatents

    Thrall, K.D.; Kenny, D.V.; Endres, G.W.R.; Sisk, D.R.

    1997-07-08

    The apparatus of the present invention is a combination of a breath interface and an external exposure dosimeter interface to a chemical analysis device, all controlled by an electronic processor for quantitatively analyzing chemical analysis data from both the breath interface and the external exposure dosimeter for determining internal tissue dose. The method of the present invention is a combination of steps of measuring an external dose, measuring breath content, then analyzing the external dose and breath content and determining internal tissue dose. 7 figs.

  5. Diagnosis of acute respiratory distress syndrome by exhaled breath analysis

    PubMed Central

    2018-01-01

    The acute respiratory distress syndrome (ARDS) is a complication of critical illness that is characterized by acute onset, protein rich, pulmonary edema. There is no treatment for ARDS, other than the reduction of additional ventilator induced lung injury. Prediction or earlier recognition of ARDS could result in preventive measurements and might decrease mortality and morbidity. Exhaled breath contains volatile organic compounds (VOCs), a collection of hundreds of small molecules linked to several physiological and pathophysiological processes. Analysis of exhaled breath through gas-chromatography and mass-spectrometry (GC-MS) has resulted in an accurate diagnosis of ARDS in several studies. Most identified markers are linked to lipid peroxidation. Octane is one of the few markers that was validated as a marker of ARDS and is pathophysiologically likely to be increased in ARDS. None of the currently studied breath analysis methods is directly applicable in clinical practice. Two steps have to be taken before any breath test can be allowed into the intensive care unit. External validation in a multi-center study is a prerequisite for any of the candidate breath markers and the breath test should outperform clinical prediction scores. Second, the technology for breath analysis should be adapted so that it is available at a decentralized lab inside the intensive care unit and can be operated by trained nurses, in order to reduce the analysis time. In conclusion, exhaled analysis might be used for the early diagnosis and prediction of ARDS in the near future but several obstacles have to be taken in the coming years. Most of the candidate markers can be linked to lipid peroxidation. Only octane has been validated in a temporal external validation cohort and is, at this moment, the top-ranking breath biomarker for ARDS. PMID:29430450

  6. A comparison of standard inhalers for asthma with and without alcohol as the propellant on the measurement of alcohol in breath.

    PubMed

    Ignacio-García, José M; Ignacio-García, Juan M; Almenara-Barrios, José; Chocrón-Giraldez, María J; Hita-Iglesias, Carmen

    2005-01-01

    Because most bronchodilator inhalers contain propellant gases or a small amount of ethanol as a co-solvent, the potential for these products to generate false readings on a evidential breath alcohol instrument was evaluated in 69 volunteers with clinically stable asthma. All subjects underwent a breath test on an infrared breath alcohol analyzer (Alcotest 7110, Dräger, Lübeck, Germany) before the use of the asthma inhaler and 1 and 5 min after inhalation. The effects of antiasthmatic medications delivered by metered dose inhalers (MDIs) with alcohol as a vehicle, alcohol-free MDIs, and dry powder inhalers were assessed in homogeneous groups of four to five patients. All subjects were alcohol-free on the preliminary breath test. One minute after inhalation, negative readings were only observed in 25 (36.2%) of subjects. In 62.3% of patients, apparent alcohol results were considered interferences or unstable readings by the breath-test instrument. One subject showed a final positive breath alcohol level (0.07 mg/L). After the use of dry powder inhalers, valid results without interferences were obtained. However, 89.6% of patients in which bronchodilators were delivered by MDIs (with propellant gases in the aerosol) showed altered partial readings and labeled the final output as "invalid," but tests performed 5 min after the use of inhalers were valid and correct in all cases. MDIs with propellants as a vehicle may cause false positive breath alcohol readings in some patients. These effects are transient and may be prevented by a 5-10-min interval between the use of MDIs and breath alcohol testing.

  7. Gated CT imaging using a free-breathing respiration signal from flow-volume spirometry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Souza, Warren D.; Kwok, Young; Deyoung, Chad

    2005-12-15

    Respiration-induced tumor motion is known to cause artifacts on free-breathing spiral CT images used in treatment planning. This leads to inaccurate delineation of target volumes on planning CT images. Flow-volume spirometry has been used previously for breath-holds during CT scans and radiation treatments using the active breathing control (ABC) system. We have developed a prototype by extending the flow-volume spirometer device to obtain gated CT scans using a PQ 5000 single-slice CT scanner. To test our prototype, we designed motion phantoms to compare image quality obtained with and without gated CT scan acquisition. Spiral and axial (nongated and gated) CTmore » scans were obtained of phantoms with motion periods of 3-5 s and amplitudes of 0.5-2 cm. Errors observed in the volume estimate of these structures were as much as 30% with moving phantoms during CT simulation. Application of motion-gated CT with active breathing control reduced these errors to within 5%. Motion-gated CT was then implemented in patients and the results are presented for two clinical cases: lung and abdomen. In each case, gated scans were acquired at end-inhalation, end-exhalation in addition to a conventional free-breathing (nongated) scan. The gated CT scans revealed reduced artifacts compared with the conventional free-breathing scan. Differences of up to 20% in the volume of the structures were observed between gated and free-breathing scans. A comparison of the overlap of structures between the gated and free-breathing scans revealed misalignment of the structures. These results demonstrate the ability of flow-volume spirometry to reduce errors in target volumes via gating during CT imaging.« less

  8. Patient training in respiratory-gated radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kini, Vijay R.; Vedam, Subrahmanya S.; Keall, Paul J.

    2003-03-31

    Respiratory gating is used to counter the effects of organ motion during radiotherapy for chest tumors. The effects of variations in patient breathing patterns during a single treatment and from day to day are unknown. We evaluated the feasibility of using patient training tools and their effect on the breathing cycle regularity and reproducibility during respiratory-gated radiotherapy. To monitor respiratory patterns, we used a component of a commercially available respiratory-gated radiotherapy system (Real Time Position Management (RPM) System, Varian Oncology Systems, Palo Alto, CA 94304). This passive marker video tracking system consists of reflective markers placed on the patient's chestmore » or abdomen, which are detected by a wall-mounted video camera. Software installed on a PC interfaced to this camera detects the marker motion digitally and records it. The marker position as a function of time serves as the motion signal that may be used to trigger imaging or treatment. The training tools used were audio prompting and visual feedback, with free breathing as a control. The audio prompting method used instructions to 'breathe in' or 'breathe out' at periodic intervals deduced from patients' own breathing patterns. In the visual feedback method, patients were shown a real-time trace of their abdominal wall motion due to breathing. Using this, they were asked to maintain a constant amplitude of motion. Motion traces of the abdominal wall were recorded for each patient for various maneuvers. Free breathing showed a variable amplitude and frequency. Audio prompting resulted in a reproducible frequency; however, the variability and the magnitude of amplitude increased. Visual feedback gave a better control over the amplitude but showed minor variations in frequency. We concluded that training improves the reproducibility of amplitude and frequency of patient breathing cycles. This may increase the accuracy of respiratory-gated radiation therapy.« less

  9. Changes in breathing pattern in the normal horse at rest up to age one year.

    PubMed

    Koterba, A M; Wozniak, J A; Kosch, P C

    1995-07-01

    Changes in pattern of airflow, sequence of respiratory muscle activation and generated pressures were measured serially in a group of foals during the first year post partum, in order to describe the maturation of the equine breathing pattern. In neonatal foals, inspiration and expiration were both primarily active and airflow pattern was essentially monophasic. By age 1 year, foals displayed essentially the same breathing pattern previously described in adult horses, utilising a combination of active and passive inspiration and expiration to breathe around, rather than from, the relaxation volume of the respiratory system (Vrx). A strong temporal relationship during growth was found between the timing of changes observed in airflow pattern and in the neuromuscular strategy of breathing. The transition to the adult breathing pattern appeared to involve a time delay in activation of both inspiratory and expiratory muscle groups, establishing a passive and active component to both inspiration and expiration. Throughout the study period, concurrent with the increase in delay of abdominal muscle activation, the expiratory flow pattern became progressively more biphasic in appearance. The time of appearance of a consistent biphasic inspiratory flow pattern was considerably later, at approximately age 1 year and coincided with the appearance of a delay in inspiratory muscle activation. From our results, we conclude that the transition from the neonatal to the adult breathing strategy in the horse appears not to be induced by the time course of chest wall stiffening during maturation. While changes in relative body proportions and size of abdominal contents during growth may influence the transition in breathing, our results also indicate that respiratory control mechanisms play an essential role in the expression of the polyphasic breathing pattern.

  10. Photoplethysmography as a single source for analysis of sleep-disordered breathing in patients with severe cardiovascular disease.

    PubMed

    Amir, Offer; Barak-Shinar, Deganit; Henry, Antonietta; Smart, Frank W

    2012-02-01

    Sleep-disordered breathing and Cheyne-Stokes breathing are often not diagnosed, especially in cardiovascular patients. An automated system based on photoplethysmographic signals might provide a convenient screening and diagnostic solution for patient evaluation at home or in an ambulatory setting. We compared event detection and classification obtained by full polysomnography (the 'gold standard') and by an automated new algorithm system in 74 subjects. Each subject underwent overnight polysomnography, 60 in a hospital cardiology department and 14 while being tested for suspected sleep-disordered breathing in a sleep laboratory. The sleep-disordered breathing and Cheyne-Stokes breathing parameters measured by a new automated algorithm system correlated very well with the corresponding results obtained by full polysomnography. The sensitivity of the Cheyne-Stokes breathing detected from the system compared to full polysomnography was 92% [95% confidence interval (CI): 78.6-98.3%] and specificity 94% (95% CI: 81.3-99.3%). Comparison of the Apnea Hyponea Index with a cutoff level of 15 shows a sensitivity of 98% (95% CI: 87.1-99.6%) and specificity of 96% (95% CI: 79.8-99.3%). The detection of respiratory events showed agreement of approximately 80%. Regression and Bland-Altman plots revealed good agreement between the two methods. Relative to gold-standard polysomnography, the simply used automated system in this study yielded an acceptable analysis of sleep- and/or cardiac-related breathing disorders. Accordingly, and given the convenience and simplicity of its application, this system can be considered as a suitable platform for home and ambulatory screening and diagnosis of sleep-disordered breathing in patients with cardiovascular disease. © 2011 European Sleep Research Society.

  11. Unloading work of breathing during high-frequency oscillatory ventilation: a bench study

    PubMed Central

    van Heerde, Marc; Roubik, Karel; Kopelent, Vitek; Plötz, Frans B; Markhorst, Dick G

    2006-01-01

    Introduction With the 3100B high-frequency oscillatory ventilator (SensorMedics, Yorba Linda, CA, USA), patients' spontaneous breathing efforts result in a high level of imposed work of breathing (WOB). Therefore, spontaneous breathing often has to be suppressed during high-frequency oscillatory ventilation (HFOV). A demand-flow system was designed to reduce imposed WOB. Methods An external gas flow controller (demand-flow system) accommodates the ventilator fresh gas flow during spontaneous breathing simulation. A control algorithm detects breathing effort and regulates the demand-flow valve. The effectiveness of this system has been evaluated in a bench test. The Campbell diagram and pressure time product (PTP) are used to quantify the imposed workload. Results Using the demand-flow system, imposed WOB is considerably reduced. The demand-flow system reduces inspiratory imposed WOB by 30% to 56% and inspiratory imposed PTP by 38% to 59% compared to continuous fresh gas flow. Expiratory imposed WOB was decreased as well by 12% to 49%. In simulations of shallow to normal breathing for an adult, imposed WOB is 0.5 J l-1 at maximum. Fluctuations in mean airway pressure on account of spontaneous breathing are markedly reduced. Conclusion The use of the demand-flow system during HFOV results in a reduction of both imposed WOB and fluctuation in mean airway pressure. The level of imposed WOB was reduced to the physiological range of WOB. Potentially, this makes maintenance of spontaneous breathing during HFOV possible and easier in a clinical setting. Early initiation of HFOV seems more possible with this system and the possibility of weaning of patients directly on a high-frequency oscillatory ventilator is not excluded either. PMID:16848915

  12. Nonrandom variability in respiratory cycle parameters of humans during stage 2 sleep.

    PubMed

    Modarreszadeh, M; Bruce, E N; Gothe, B

    1990-08-01

    We analyzed breath-to-breath inspiratory time (TI), expiratory time (TE), inspiratory volume (VI), and minute ventilation (Vm) from 11 normal subjects during stage 2 sleep. The analysis consisted of 1) fitting first- and second-order autoregressive models (AR1 and AR2) and 2) obtaining the power spectra of the data by fast-Fourier transform. For the AR2 model, the only coefficients that were statistically different from zero were the average alpha 1 (a1) for TI, VI, and Vm (a1 = 0.19, 0.29, and 0.15, respectively). However, the power spectra of all parameters often exhibited peaks at low frequency (less than 0.2 cycles/breath) and/or at high frequency (greater than 0.2 cycles/breath), indicative of periodic oscillations. After accounting for the corrupting effects of added oscillations on the a1 estimates, we conclude that 1) breath-to-breath fluctuations of VI, and to a lesser extent TI and Vm, exhibit a first-order autoregressive structure such that fluctuations of each breath are positively correlated with those of immediately preceding breaths and 2) the correlated components of variability in TE are mostly due to discrete high- and/or low-frequency oscillations with no underlying autoregressive structure. We propose that the autoregressive structure of VI, TI, and Vm during spontaneous breathing in stage 2 sleep may reflect either a central neural mechanism or the effects of noise in respiratory chemical feedback loops; the presence of low-frequency oscillations, seen more often in Vm, suggests possible instability in the chemical feedback loops. Mechanisms of high-frequency periodicities, seen more often in TE, are unknown.

  13. Unilateral ablation of pre-Botzinger complex disrupts breathing during sleep but not wakefulness.

    PubMed

    McKay, Leanne C; Feldman, Jack L

    2008-07-01

    In adult rats, bilateral ablation of pre-Bötzinger complex (preBötC) neurokinin 1-expressing (NK1R) neurons leads to a progressive and irreversible disruption in breathing pattern, initially during sleep, eventually resulting in an ataxic breathing pattern during wakefulness. Here we determine whether ablation of fewer preBötC NK1R neurons leads to a persistent pattern of disordered breathing during sleep but not during wakefulness. Adult male Sprague-Dawley rats (n = 12) were instrumented to record diaphragmatic, abdominal, and neck EMG, and EEG. Fourteen days later, a second surgery was performed to stereotaxically microinject into the preBötC on one side the toxin saporin conjugated to substance P (SP-SAP), which selectively ablates NK1R neurons. Postinjection, rats were monitored within a plethysmograph until they were killed (Days 21-51). At Days 6-9 post-unilateral SP-SAP injection, respiratory pattern during sleep, particularly REM sleep, became increasingly disordered, characterized by an increase in frequency of central sleep apnea and hypopneas (36.8 +/- 7.4 episodes/h of REM vs. 6 +/- 2.0 episodes/h in preinjection controls; P < 0.05), whereas breathing during resting wakefulness remained stable. Unlike bilateral SP-SAP-injected rats, an ataxic breathing pattern did not develop during wakefulness. Rats that were monitored up to 51 days post-SP-SAP injection continued to have sleep-disordered breathing; breathing during wakefulness remained relatively stable. Histologic analysis of the ventrolateral medulla confirmed that NK1R neurons within the preBötC on the injected but not on the contralateral side of the medulla were ablated. Gradual loss of preBötC NK1R neurons may be an underlying factor of sleep-disordered breathing, in particular of central sleep apnea.

  14. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing.

    PubMed

    Donaldsson, Snorri; Falk, Markus; Jonsson, Baldvin; Drevhammar, Thomas

    2015-01-01

    The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates.

  15. Imposed Work of Breathing for Flow Meters with In-Line versus Flow-Through Technique during Simulated Neonatal Breathing

    PubMed Central

    2015-01-01

    Background The ability to determine airflow during nasal CPAP (NCPAP) treatment without adding dead space or resistance would be useful when investigating the physiologic effects of different NCPAP systems on breathing. The aim of this study was to investigate the effect on pressure stability of different flow measuring devices at the in-line and flow-through position, using simulated neonatal breathing. Methods Six different flow measure devices were evaluated by recording pressure changes and imposed work of breathing for breaths with 16 and 32 ml tidal volumes. The tests were performed initially with the devices in an in line position and with 5 and 10 L/min using flow through technique, without CPAP. The flow meters were then subsequently tested with an Infant Flow CPAP system at 3, 5 and 8 cm H2O pressure using flow through technique. The quality of the recorded signals was compared graphically. Results The resistance of the measuring devices generated pressure swings and imposed work of breathing. With bias flow, the resistance also generated CPAP pressure. Three of the devices had low resistance and generated no changes in pressure stability or CPAP pressure. The two devices intended for neonatal use had the highest measured resistance. Conclusion The importance of pressure stability and increased work of breathing during non-invasive respiratory support are insufficiently studied. Clinical trials using flow-through technique have not focused on pressure stability. Our results indicate that a flow-through technique might be a way forward in obtaining a sufficiently high signal quality without the added effects of rebreathing and increased work of breathing. The results should stimulate further research and the development of equipment for dynamic flow measurements in neonates. PMID:26192188

  16. Ontogenetic changes and developmental adjustments in lactate dehydrogenase isozymes of an obligate air-breathing fish Channa punctatus during deprivation of air access.

    PubMed

    Ahmad, Riaz; Hasnain, Absar-Ul

    2005-02-01

    In air-breathing snakehead Channa punctatus, Ldh-B is expressed at all ontogenetic and developmental stages, while Ldh-A is expressed temporally in pre-hatchlings 12-13 days ahead of bimodal respiration marked by air-breathing. Remarkable differences are observed in the LDH isozyme expression among various ontogenetic and developmental stages upon denying air access. When denied air access, water-breathing larvae show two distinct characteristics: (i) they survive longer than transitory air-breathers due to independence from air-breathing and (ii) there is more transient induction of Ldh-B than Ldh-A. Transition to bimodal breathing, which occurred post-hatching in 15-day old larvae, is coincidental with inducibility of Ldh-A and concomitant down-regulation of Ldh-B. Heart tissue from air-breathing adults denied air access shows a preferential expression of LDH-A subunit and slight down-regulation of LDH-B. Heterotetramers of A and B subunits participate in adjusting LDH levels among those stages which either precede air-breathing switchover, or are subsequent to this transition. The contribution of heterotetramers depends on the stage-specific levels of LDH homotetramers A(4) or B(4). Scaling of muscle mass during growth, tolerance to extended deprivation of air access and induction of Ldh-A are correlated. Response to restoring air contact indicated that advanced air-breathing stages of C. punctatus possess an inherent capacity to sense surface air. In kinetic properties, LDH isozymes of C. punctatus are teleost-like but species specificity is displayed in oxidative potential by cardiac muscle and in L-lactate reduction by skeletal muscle.

  17. Collecting Protein Biomarkers in Breath Using Electret Filters: A Preliminary Method on New Technical Model and Human Study.

    PubMed

    Li, Wang; Pi, Xitian; Qiao, Panpan; Liu, Hongying

    2016-01-01

    Biomarkers in exhaled breath are useful for respiratory disease diagnosis in human volunteers. Conventional methods that collect non-volatile biomarkers, however, necessitate an extensive dilution and sanitation processes that lowers collection efficiencies and convenience of use. Electret filter emerged in recent decade to collect virus biomarkers in exhaled breath given its simplicity and effectiveness. To investigate the capability of electret filters to collect protein biomarkers, a model that consists of an atomizer that produces protein aerosol and an electret filter that collects albumin and carcinoembryonic antigen-a typical biomarker in lung cancer development- from the atomizer is developed. A device using electret filter as the collecting medium is designed to collect human albumin from exhaled breath of 6 volunteers. Comparison of the collecting ability between the electret filter method and other 2 reported methods is finally performed based on the amounts of albumin collected from human exhaled breath. In conclusion, a decreasing collection efficiency ranging from 17.6% to 2.3% for atomized albumin aerosol and 42% to 12.5% for atomized carcinoembryonic antigen particles is found; moreover, an optimum volume of sampling human exhaled breath ranging from 100 L to 200 L is also observed; finally, the self-designed collecting device shows a significantly better performance in collecting albumin from human exhaled breath than the exhaled breath condensate method (p<0.05) but is not significantly more effective than reported 3-stage impactor method (p>0.05). In summary, electret filters are potential in collecting non-volatile biomarkers in human exhaled breath not only because it was simpler, cheaper and easier to use than traditional methods but also for its better collecting performance.

  18. Exhaled breath profiling using broadband quantum cascade laser-based spectroscopy in healthy children and children with asthma and cystic fibrosis.

    PubMed

    van Mastrigt, E; Reyes-Reyes, A; Brand, K; Bhattacharya, N; Urbach, H P; Stubbs, A P; de Jongste, J C; Pijnenburg, M W

    2016-04-08

    Exhaled breath analysis is a potential non-invasive tool for diagnosing and monitoring airway diseases. Gas chromatography-mass spectrometry and electrochemical sensor arrays are the main techniques to detect volatile organic compounds (VOC) in exhaled breath. We developed a broadband quantum cascade laser spectroscopy technique for VOC detection and identification. The objective of this study was to assess the repeatability of exhaled breath profiling with broadband quantum cascade laser-based spectroscopy and to explore the clinical applicability by comparing exhaled breath samples from healthy children with those from children with asthma or cystic fibrosis (CF). Healthy children and children with stable asthma or stable CF, aged 6-18 years, were included. Two to four exhaled breath samples were collected in Tedlar bags and analyzed by quantum cascade laser spectroscopy to detect VOCs with an absorption profile in the wavenumber region between 832 and 1262.55 cm(-1). We included 35 healthy children, 39 children with asthma and 15 with CF. Exhaled breath VOC profiles showed poor repeatability (Spearman's rho  =  0.36 to 0.46) and agreement of the complete profiles. However, we were able to discriminate healthy children from children with stable asthma or stable CF and identified VOCs that were responsible for this discrimination. Broadband quantum cascade laser-based spectroscopy detected differences in VOC profiles in exhaled breath samples between healthy children and children with asthma or CF. The combination of a relatively easy and fast method and the possibility of molecule identification makes broadband quantum cascade laser-based spectroscopy attractive to investigate the diagnostic and prognostic potential of volatiles in exhaled breath.

  19. Measurement of fatigue following 18 msw dry chamber dives breathing air or enriched air nitrox.

    PubMed

    Harris, R J D; Doolette, D J; Wilkinson, D C; Williams, D J

    2003-01-01

    Many divers report less fatigue following diving breathing oxygen rich N2-O2 mixtures compared with breathing air. In this double blinded, randomized controlled study 11 divers breathed either air or Enriched Air Nitrox 36% (oxygen 36%, nitrogen 64%) during an 18 msw (281 kPa(a)) dry chamber dive for a bottom time of 40 minutes. Two periods of exercise were performed during the dive. Divers were assessed before and after each dive using the Multidimensional Fatigue Inventory-20, a visual analogue scale, Digit Span Tests, Stroop Tests, and Divers Health Survey (DHS). Diving to 18m produced no measurable difference in fatigue, attention levels, ability to concentrate or DHS scores, following dives using either breathing gas.

  20. [*C]octanoic acid breath test to measure gastric emptying rate of solids.

    PubMed

    Maes, B D; Ghoos, Y F; Rutgeerts, P J; Hiele, M I; Geypens, B; Vantrappen, G

    1994-12-01

    We have developed a breath test to measure solid gastric emptying using a standardized scrambled egg test meal (250 kcal) labeled with [14C]octanoic acid or [13C]octanoic acid. In vitro incubation studies showed that octanoic acid is a reliable marker of the solid phase. The breath test was validated in 36 subjects by simultaneous radioscintigraphic and breath test measurements. Nine healthy volunteers were studied after intravenous administration of 200 mg erythromycin and peroral administration of 30 mg propantheline, respectively. Erythromycin significantly enhanced gastric emptying, while propantheline significantly reduced gastric emptying rates. We conclude that the [*C]octanoic breath test is a promising and reliable test for measuring the gastric emptying rate of solids.

  1. Inter- and intraobserver agreement of ADC measurements of lung cancer in free breathing, breath-hold and respiratory triggered diffusion-weighted MRI.

    PubMed

    Cui, Lei; Yin, Jian-Bing; Hu, Chun-Hong; Gong, Shen-Chu; Xu, Jun-Feng; Yang, Ju-Shun

    2016-01-01

    To prospectively evaluate the inter- and intraobserver agreement of apparent diffusion coefficient (ADC) measurements in free breathing, breath-hold, and respiratory triggered diffusion-weighted imaging (DWI) of lung cancer. Twenty-two patients with lung cancer (tumor size >2cm) underwent DWIs (3.0T) in three imaging methods. Lesion ADCs were measured twice by both of the two independent observers and compared. No statistical significance was found among methods, though respiratory-triggered DWI tended to have higher ADCs than breath-hold DWI. Great inter- and intraobserver agreement was shown. ADCs had good inter- and intraobserver agreement in all three DWI methods. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Characterising non-linear dynamics in nocturnal breathing patterns of healthy infants using recurrence quantification analysis.

    PubMed

    Terrill, Philip I; Wilson, Stephen J; Suresh, Sadasivam; Cooper, David M; Dakin, Carolyn

    2013-05-01

    Breathing dynamics vary between infant sleep states, and are likely to exhibit non-linear behaviour. This study applied the non-linear analytical tool recurrence quantification analysis (RQA) to 400 breath interval periods of REM and N-REM sleep, and then using an overlapping moving window. The RQA variables were different between sleep states, with REM radius 150% greater than N-REM radius, and REM laminarity 79% greater than N-REM laminarity. RQA allowed the observation of temporal variations in non-linear breathing dynamics across a night's sleep at 30s resolution, and provides a basis for quantifying changes in complex breathing dynamics with physiology and pathology. Copyright © 2013 Elsevier Ltd. All rights reserved.

  3. Chemical Analysis of Exhaled Human Breath Using High Resolution Mm-Wave Rotational Spectra

    NASA Astrophysics Data System (ADS)

    Guo, Tianle; Branco, Daniela; Thomas, Jessica; Medvedev, Ivan; Dolson, David; Nam, Hyun-Joo; O, Kenneth

    2014-06-01

    High resolution rotational spectroscopy enables chemical sensors that are both sensitive and highly specific, which is well suited for analysis of expired human breath. We have previously reported on detection of breath ethanol, methanol, acetone, and acetaldehyde using THz sensors. This paper will outline our present efforts in this area, with specific focus on our ongoing quest to correlate levels of blood glucose with concentrations of a few breath chemicals known to be affected by elevated blood sugar levels. Prospects, challenges and future plans will be outlined and discussed. Fosnight, A.M., B.L. Moran, and I.R. Medvedev, Chemical analysis of exhaled human breath using a terahertz spectroscopic approach. Applied Physics Letters, 2013. 103(13): p. 133703-5.

  4. 46 CFR 154.1852 - Air breathing equipment.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Air breathing equipment. 154.1852 Section 154.1852 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Operations § 154.1852 Air breathing...

  5. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  6. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  7. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  8. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Breathing bag test. 84.88 Section 84.88 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing...

  9. STS-46 MS Hoffman and MS Chang-Diaz wear masks during pre-breathe on OV-104

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Mission Specialist (MS) and Payload Commander (PLC) Jeffrey A. Hoffman and MS Franklin R. Chang-Diaz, wearing breathing apparatus masks, pose on the forward flight deck of Atlantis, Orbiter Vehicle (OV) 104, during pre-breathe session. With the possibility of an extravehicular activity (EVA) being added to the STS-46 agenda, the astronauts reported to this station and began the 'pre-breathe' process when problems developed during the extension of the Tethered Satellite System 1 (TSS-1). When the human body is exposed to a sudden decrease in atmospheric pressure (for instance, from the 10.2 ppsi in the crew cabin to the 4.5 ppsi of the extravehicular mobility unit (EMU)), nitrogen traces in the bloodstream will expand. This expansion can create tiny bubbles and potential for the 'bends'. In order to lessen the effect, an astronaut must 'pre-breathe' pure oxygen (the same pure oxygen he will breathe in the suit) to help 'purge' nitrogen from his bloodstream before exerting himself

  10. The US Navy/Canadian DCIEM research initiative on pressure breathing physiology

    NASA Technical Reports Server (NTRS)

    Whitley, Phillip E.

    1994-01-01

    Development of improved positive pressure breathing garments for altitude and acceleration protection has occurred without collection of sufficient physiological data to understand the mechanisms of the improvement. Furthermore, modeling of the predicted response of future enhanced garments is greatly hampered by this lack of information. A joint, international effort is under way between Canada's Defense and Civil Institute for Environmental Medicine (DCIEM) and the US Navy's Naval Air Warfare Center Aircraft Division, Warminster (NAWCACDIVWAR). Using a Canadian subject pool, experiments at both the DCIEM altitude facility and the NAWCADIVWAR Dynamic Flight Simulator have been conducted to determine the cardiovascular and respiratory consequences of high levels of positive pressure breathing for altitude and positive pressure breathing for acceleration protection. Various improved pressure breathing garments were used to collect comparative physiological and performance data. New pressure breathing level and durahon capabilities have been encountered. Further studies will address further improvements in pressure suit design and correlation of altitude and acceleration data.

  11. The ins and outs of breath holding: simple demonstrations of complex respiratory physiology.

    PubMed

    Skow, Rachel J; Day, Trevor A; Fuller, Jonathan E; Bruce, Christina D; Steinback, Craig D

    2015-09-01

    The physiology of breath holding is complex, and voluntary breath-hold duration is affected by many factors, including practice, psychology, respiratory chemoreflexes, and lung stretch. In this activity, we outline a number of simple laboratory activities or classroom demonstrations that illustrate the complexity of the integrative physiology behind breath-hold duration. These activities require minimal equipment and are easily adapted to small-group demonstrations or a larger-group inquiry format where students can design a protocol and collect and analyze data from their classmates. Specifically, breath-hold duration is measured during a number of maneuvers, including after end expiration, end inspiration, voluntary prior hyperventilation, and inspired hyperoxia. Further activities illustrate the potential contribution of chemoreflexes through rebreathing and repeated rebreathing after a maximum breath hold. The outcome measures resulting from each intervention are easily visualized and plotted and can comprise a comprehensive data set to illustrate and discuss complex and integrated cardiorespiratory physiology. Copyright © 2015 The American Physiological Society.

  12. New operational technology of intrauterine ventilation the fetus lungs by breathing gas

    NASA Astrophysics Data System (ADS)

    Urakov, A. L.; Nikityuk, D. B.; Urakova, N. A.; Kasankin, A. A.; Chernova, L. V.; Dementiev, V. B.

    2015-11-01

    New operational technology for elimination intrauterine hypoxia and asphyxia of the fetus using endoscopic artificial ventilation lungs by respiratory gas was developed. For intrauterine ventilation of fetal lung it is proposed to enter into the uterus a special breathing mask and wear it on the head of the fetus using the original endoscopic technology. The breathing mask, developed by us is connected with external breathing apparatus with a hose. The device is called "intrauterine aqualung". Intrauterine aqualung includes a ventilator and breathing circuit with a special fold-out breathing mask that is put on inside the uterus on the head of fetus like a mesh hat. Controlled by ultrasound the technology of the introduction of the mask inside of the uterus through the natural opening in the cervix and technology of putting on the respiratory mask on the head of the fetus with its head previa were developed. The technology intrauterine ventilation of the fetus lungs by respiratory gas was developed.

  13. Tele-auscultation support system with mixed reality navigation.

    PubMed

    Hori, Kenta; Uchida, Yusuke; Kan, Tsukasa; Minami, Maya; Naito, Chisako; Kuroda, Tomohiro; Takahashi, Hideya; Ando, Masahiko; Kawamura, Takashi; Kume, Naoto; Okamoto, Kazuya; Takemura, Tadamasa; Yoshihara, Hiroyuki

    2013-01-01

    The aim of this research is to develop an information support system for tele-auscultation. In auscultation, a doctor requires to understand condition of applying a stethoscope, in addition to auscultatory sounds. The proposed system includes intuitive navigation system of stethoscope operation, in addition to conventional audio streaming system of auscultatory sounds and conventional video conferencing system for telecommunication. Mixed reality technology is applied for intuitive navigation of the stethoscope. Information, such as position, contact condition and breath, is overlaid on a view of the patient's chest. The contact condition of the stethoscope is measured by e-textile contact sensors. The breath is measured by a band type breath sensor. In a simulated tele-auscultation experiment, the stethoscope with the contact sensors and the breath sensor were evaluated. The results show that the presentation of the contact condition was not understandable enough for navigating the stethoscope handling. The time series of the breath phases was usable for the remote doctor to understand the breath condition of the patient.

  14. A Ringdown Breath Analyzer for Diabetes Monitoring: Breath Acetone in Diabetic Patients.

    NASA Astrophysics Data System (ADS)

    Wang, Chuji; Mbi, Armstrong; Shepherd, Mark

    2008-03-01

    It is highly desirable for millions of diabetic patients to have a non-blood, non-invasive, point-of-care device for monitoring daily blood glucose (BG) levels and the adequacy of diabetic treatment and control. Cavity ringdown spectroscopy, due to its unique capability of high sensitivity, fast-response, and relatively low cost for instrumentation, has the potential for medical application through non-invasive analysis of breath biomarkers. We report the first ringdown acetone breath analyzer for clinic testing with diabetic outpatients. The instrument was set in a clinic center and 34 outpatients (24 T1D and 10 T2D) were tested during a four-day period. 10 T1D subjects and 15 nondiabetic persons were tested in our laboratory. Three juvenile-onset T1D subjects were selected for a 24-hr monitoring on the variations of breath acetone and simultaneous BG level. In this talk, we present our research findings including the correlations of breath acetone with BG level and A1C.

  15. Application of cabin atmosphere monitors to rapid screening of breath samples for the early detection of disease states

    NASA Technical Reports Server (NTRS)

    Valentine, J. L.; Bryant, P. J.

    1975-01-01

    Analysis of human breath is a nonintrusive method to monitor both endogenous and exogenous chemicals found in the body. Several technologies were investigated and developed which are applicable to monitoring some organic molecules important in both physiological and pathological states. Two methods were developed for enriching the organic molecules exhaled in the breath of humans. One device is based on a respiratory face mask fitted with a polyethylene foam wafer; while the other device is a cryogenic trap utilizing an organic solvent. Using laboratory workers as controls, two organic molecules which occurred in the enriched breath of all subjects were tentatively identified as lactic acid and contisol. Both of these substances occurred in breath in sufficient amounts that the conventional method of gas-liquid chromatography was adequate for detection and quantification. To detect and quantitate trace amounts of chemicals in breath, another type of technology was developed in which analysis was conducted using high pressure liquid chromatography and mass spectrometry.

  16. Development of an Exhaled Breath Monitoring System with Semiconductive Gas Sensors, a Gas Condenser Unit, and Gas Chromatograph Columns

    PubMed Central

    Itoh, Toshio; Miwa, Toshio; Tsuruta, Akihiro; Akamatsu, Takafumi; Izu, Noriya; Shin, Woosuck; Park, Jangchul; Hida, Toyoaki; Eda, Takeshi; Setoguchi, Yasuhiro

    2016-01-01

    Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis. PMID:27834896

  17. Risk of Neurological Insult in Competitive Deep Breath-Hold Diving.

    PubMed

    Tetzlaff, Kay; Schöppenthau, Holger; Schipke, Jochen D

    2017-02-01

    It has been widely believed that tissue nitrogen uptake from the lungs during breath-hold diving would be insufficient to cause decompression stress in humans. With competitive free diving, however, diving depths have been ever increasing over the past decades. A case is presented of a competitive free-diving athlete who suffered stroke-like symptoms after surfacing from his last dive of a series of 3 deep breath-hold dives. A literature and Web search was performed to screen for similar cases of subjects with serious neurological symptoms after deep breath-hold dives. A previously healthy 31-y-old athlete experienced right-sided motor weakness and difficulty speaking immediately after surfacing from a breathhold dive to a depth of 100 m. He had performed 2 preceding breath-hold dives to that depth with surface intervals of only 15 min. The presentation of symptoms and neuroimaging findings supported a clinical diagnosis of stroke. Three more cases of neurological insults were retrieved by literature and Web search; in all cases the athletes presented with stroke-like symptoms after single breath-hold dives of depths exceeding 100 m. Two of these cases only had a short delay to recompression treatment and completely recovered from the insult. This report highlights the possibility of neurological insult, eg, stroke, due to cerebral arterial gas embolism as a consequence of decompression stress after deep breath-hold dives. Thus, stroke as a clinical presentation of cerebral arterial gas embolism should be considered another risk of extreme breath-hold diving.

  18. Detection of nitric oxide in exhaled human breath: exercise and resting determinations.

    PubMed

    Mantione, Kirk J; Esch, Tobias; Stefano, George B

    2007-03-01

    Nitric oxide has become a vital indicator of health since many cells produce it constitutively. It is present in exhaled breath and can be measured. A Kiernan NO Breath analyzer (KNB) was used in the present study to determine nitric oxide (NO) levels in exhaled human breath. The KNB was calibrated via measuring NO gas in O2-free N2 obtained from Scott Specialty Gases. Human subjects aged 21 to 45 were instructed to place the KNB over their nose and mouth and to breathe normally before and after mild exercise (n=24) and relaxation (n=20). Mean exhaled NO measurements were compared before and after the protocols using paired t-tests. Regardless of the test, all subjects exhibited NO in their exhaled breath. Exhaled NO decreased significantly after exercise compared to the first reading just prior to the exercise protocol. The mean +/-SE of exhaled NO was 22.8+/-4 before and 13.0+/-2 ppb after exercise (n=24, P=0.003). In the resting experiment, exhaled NO was demonstrated to increase significantly after 10 min compared to the reading taken right after the individuals sat down. The present study demonstrates NO in exhaled human breath can vary, reflecting the activity state of the individual. Additionally, the study demonstrates that NO in exhaled human breath can be measured rapidly, with high sensitivity, and in real time via the KNB, representing an affordable means to achieve this determination.

  19. A metabolic simulator for unmanned testing of breathing apparatuses in hyperbaric conditions.

    PubMed

    Frånberg, Oskar; Loncar, Mario; Larsson, Åke; Ornhagen, Hans; Gennser, Mikael

    2014-11-01

    A major part of testing of rebreather apparatuses for underwater diving focuses on the oxygen dosage system. A metabolic simulator for testing breathing apparatuses was built and evaluated. Oxygen consumption was achieved through catalytic combustion of propene. With an admixture of carbon dioxide in the propene fuel, the system allowed the respiratory exchange ratio to be set freely within human variability and also made it possible to increase test pressures above the condensation pressure of propene. The system was tested by breathing ambient air in a pressure chamber with oxygen uptake (Vo₂) ranging from 1-4 L · min(-1), tidal volume (VT) from 1-3 L, breathing frequency (f) of 20 and 25 breaths/min, and chamber pressures from 100 to 670 kPa. The measured end-tidal oxygen concentration (Fo₂) was compared to calculated end-tidal Fo₂. The largest average difference in end-tidal Fo₂during atmospheric pressure conditions was 0.63%-points with a 0.28%-point average difference during the whole test. During hyperbaric conditions with pressures ranging from 100 to 670 kPa, the largest average difference in Fo₂was 1.68%-points seen during compression from 100 kPa to 400 kPa and the average difference in Fo₂during the whole test was 0.29%-points. In combination with a breathing simulator simulating tidal breathing, the system can be used for dynamic continuous testing of breathing equipment with changes in VT, f, Vo2, and pressure.

  20. Frequency of rhinitis and orofacial disorders in patients with dental malocclusion

    PubMed Central

    Imbaud, Tamara Christine de Souza; Mallozi, Márcia Carvalho; Domingos, Vanda Beatriz Teixeira Coelho; Solé, Dirceu

    2016-01-01

    Abstract Objective: To describe the frequency and etiology of rhinitis, oral breathing, types of malocclusion and orofacial disorders in patients treated for dental malocclusion. Methods: Patients with poor dental occlusion (n=89, 8-15 years) undergoing orthodontic treatment at the Postgraduate Orthodontics Center (São Paulo, Brazil) participated in the study. Rhinitis and oral breathing were diagnosed by anamnesis, clinical assessment and allergic etiology of rhinitis through immediate hypersensitivity skin prick test with airborne allergens. The association between types of breathing (oral or nasal), rhinitis and types of dental malocclusion, bruxism and cephalometric alterations (increased Y axis of facial growth) compared to standard cephalometric tracing (Escola de Odontologia da Universidade de São Paulo) were assessed. Results: The frequency of rhinitis in patients with dental malocclusion was 76.4% (68), and, of these, 81.7% were allergic (49/60 positive skin prick test), whereas the frequency of oral breathing was 62.9%. There was a significant association between an increased Y axis of facial growth and oral breathing (p<0.001), as well as between oral breathing and rhinitis (p=0.009). There was no association between rhinitis and bruxism. Conclusions: The frequency of rhinitis in children with dental malocclusion is higher than that in the general population, which is approximately 30%. Patients with oral breathing have a tendency to a dolichofacial growth pattern (increased Y axis of facial growth). In patients with rhinitis, regardless of the presence of oral breathing, the dolichofacial growth tendency was not observed. PMID:26631324

  1. Breath carbon stable isotope ratios identify changes in energy balance and substrate utilization in humans.

    PubMed

    Whigham, L D; Butz, D E; Johnson, L K; Schoeller, D A; Abbott, D H; Porter, W P; Cook, M E

    2014-09-01

    Rapid detection of shifts in substrate utilization and energy balance would provide a compelling biofeedback tool for individuals attempting weight loss. As a proof of concept, we tested whether the natural abundance of exhaled carbon stable isotope ratios (breath δ(13)C) reflects shifts between negative and positive energy balance. Volunteers (n=5) consumed a 40% energy-restricted diet for 6 days followed by 50% excess on day 7. Breath was sampled immediately before and 1 h and 2 h after breakfast, lunch and dinner. Exhaled breath δ(13)C values were measured by cavity ring-down spectroscopy. Using repeated measures analysis of variance (ANOVA) followed by Dunnett's contrasts, pre-breakfast breath values on days 2-6 were compared with day 1, and postprandial day 7 time points were compared with pre-breakfast day 7. Energy restriction diminished pre-breakfast breath δ(13)C by day 3 (P<0.05). On day 7, increased energy intake was first detected immediately before dinner (-23.8±0.6 vs -21.9±0.7‰, P=0.002 (means±s.d.)), and breath δ(13)C remained elevated at least 2 h post dinner. In conclusion, when shifting between negative and positive energy balance, breath δ(13)C showed anticipated isotopic changes. Although additional research is needed to determine specificity and repeatability, this method may provide a biomarker for marked increases in caloric intake.

  2. Optimal ventilatory patterns in periodic breathing.

    PubMed

    Ghazanshahi, S D; Khoo, M C

    1993-01-01

    The goal of this study was to determine whether periodic breathing (PB), which is highly prevalent during sleep at high altitudes, imposes physiological penalties on the respiratory system in the absence of any accompanying disease. Using a computer model of respiratory gas exchange, we compared the effects of a variety of PB patterns on the chemical and mechanical costs of breathing to those resulting from regular tidal breathing. Although PB produced considerable fluctuation in arterial blood gas tensions, for the same cycle-averaged ventilation, higher arterial oxygen saturation and lower arterial carbon dioxide levels were achieved. This result can be explained by the fact that the combination of large breaths and apnea in PB leads to a substantial reduction in dead space ventilation. At the same time, the savings in mechanical cost achieved by the respiratory muscles during apnea partially offset the increase during the breathing phase. Consequently, the "pressure cost," a criterion based on mean inspiratory pressure, was elevated only slightly, although the average work rate of breathing increased significantly. We found that, at extreme altitudes, PB patterns with clusters of 2 to 4 large breaths that alternate with apnea produce the highest arterial oxygenation levels and lowest pressure costs. The common occurrence of PB patterns with closely similar features has been reported in sleeping healthy sojourners at extreme altitudes. Taken together, these findings suggest that PB favors a reduction in the oxygen demands of the respiratory muscles and therefore may not be as detrimental as it is generally believed to be.

  3. Speech-language pathology findings in patients with mouth breathing: multidisciplinary diagnosis according to etiology.

    PubMed

    Junqueira, Patrícia; Marchesan, Irene Queiroz; de Oliveira, Luciana Regina; Ciccone, Emílio; Haddad, Leonardo; Rizzo, Maria Cândida

    2010-11-01

    The purpose of this study was to identify and compare the results of the findings from speech-language pathology evaluations for orofacial function including tongue and lip rest postures, tonus, articulation and speech, voice and language, chewing, and deglutition in children who had a history of mouth breathing. The diagnoses for mouth breathing included: allergic rhinitis, adenoidal hypertrophy, allergic rhinitis with adenoidal hypertrophy; and/or functional mouth breathing. This study was conducted with on 414 subjects of both genders, from 2 to 16-years old. A team consisting of 3 speech-language pathologists, 1 pediatrician, 1 allergist, and 1 otolaryngologist, evaluated the patients. Multidisciplinary clinical examinations were carried out (complete blood counting, X-rays, nasofibroscopy, audiometry). The two most commonly found etiologies were allergic rhinitis, followed by functional mouth breathing. Of the 414 patients in the study, 346 received a speech-language pathology evaluation. The most prevalent finding in this group of 346 subjects was the presence of orofacial myofunctional disorders. The most frequently orofacial myofunctional disorder identified in these subjects who also presented mouth breathing included: habitual open lips rest posture, low and forward tongue rest posture and lack of adequate muscle tone. There were also no statistically significant relationships identified between etiology and speech-language diagnosis. Therefore, the specific type of etiology of mouth breathing does not appear to contribute to the presence, type, or number of speech-language findings which may result from mouth breathing behavior.

  4. Classification of postural profiles among mouth-breathing children by learning vector quantization.

    PubMed

    Mancini, F; Sousa, F S; Hummel, A D; Falcão, A E J; Yi, L C; Ortolani, C F; Sigulem, D; Pisa, I T

    2011-01-01

    Mouth breathing is a chronic syndrome that may bring about postural changes. Finding characteristic patterns of changes occurring in the complex musculoskeletal system of mouth-breathing children has been a challenge. Learning vector quantization (LVQ) is an artificial neural network model that can be applied for this purpose. The aim of the present study was to apply LVQ to determine the characteristic postural profiles shown by mouth-breathing children, in order to further understand abnormal posture among mouth breathers. Postural training data on 52 children (30 mouth breathers and 22 nose breathers) and postural validation data on 32 children (22 mouth breathers and 10 nose breathers) were used. The performance of LVQ and other classification models was compared in relation to self-organizing maps, back-propagation applied to multilayer perceptrons, Bayesian networks, naive Bayes, J48 decision trees, k, and k-nearest-neighbor classifiers. Classifier accuracy was assessed by means of leave-one-out cross-validation, area under ROC curve (AUC), and inter-rater agreement (Kappa statistics). By using the LVQ model, five postural profiles for mouth-breathing children could be determined. LVQ showed satisfactory results for mouth-breathing and nose-breathing classification: sensitivity and specificity rates of 0.90 and 0.95, respectively, when using the training dataset, and 0.95 and 0.90, respectively, when using the validation dataset. The five postural profiles for mouth-breathing children suggested by LVQ were incorporated into application software for classifying the severity of mouth breathers' abnormal posture.

  5. Solid-state gas sensors for breath analysis: a review.

    PubMed

    Di Natale, Corrado; Paolesse, Roberto; Martinelli, Eugenio; Capuano, Rosamaria

    2014-05-08

    The analysis of volatile compounds is an efficient method to appraise information about the chemical composition of liquids and solids. This principle is applied to several practical applications, such as food analysis where many important features (e.g. freshness) can be directly inferred from the analysis of volatile compounds. The same approach can also be applied to a human body where the volatile compounds, collected from the skin, the breath or in the headspace of fluids, might contain information that could be used to diagnose several kinds of diseases. In particular, breath is widely studied and many diseases can be potentially detected from breath analysis. The most fascinating property of breath analysis is the non-invasiveness of the sample collection. Solid-state sensors are considered the natural complement to breath analysis, matching the non-invasiveness with typical sensor features such as low-cost, easiness of use, portability, and the integration with the information networks. Sensors based breath analysis is then expected to dramatically extend the diagnostic capabilities enabling the screening of large populations for the early diagnosis of pathologies. In the last years there has been an increased attention to the development of sensors specifically aimed to this purpose. These investigations involve both specific sensors designed to detect individual compounds and non-specific sensors, operated in array configurations, aimed at clustering subjects according to their health conditions. In this paper, the recent significant applications of these sensors to breath analysis are reviewed and discussed. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. An Ultrasonic Contactless Sensor for Breathing Monitoring

    PubMed Central

    Arlotto, Philippe; Grimaldi, Michel; Naeck, Roomila; Ginoux, Jean-Marc

    2014-01-01

    The monitoring of human breathing activity during a long period has multiple fundamental applications in medicine. In breathing sleep disorders such as apnea, the diagnosis is based on events during which the person stops breathing for several periods during sleep. In polysomnography, the standard for sleep disordered breathing analysis, chest movement and airflow are used to monitor the respiratory activity. However, this method has serious drawbacks. Indeed, as the subject should sleep overnight in a laboratory and because of sensors being in direct contact with him, artifacts modifying sleep quality are often observed. This work investigates an analysis of the viability of an ultrasonic device to quantify the breathing activity, without contact and without any perception by the subject. Based on a low power ultrasonic active source and transducer, the device measures the frequency shift produced by the velocity difference between the exhaled air flow and the ambient environment, i.e., the Doppler effect. After acquisition and digitization, a specific signal processing is applied to separate the effects of breath from those due to subject movements from the Doppler signal. The distance between the source and the sensor, about 50 cm, and the use of ultrasound frequency well above audible frequencies, 40 kHz, allow monitoring the breathing activity without any perception by the subject, and therefore without any modification of the sleep quality which is very important for sleep disorders diagnostic applications. This work is patented (patent pending 2013-7-31 number FR.13/57569). PMID:25140632

  7. Afternoon serum-melatonin in sleep disordered breathing.

    PubMed

    Ulfberg, J; Micic, S; Strøm, J

    1998-08-01

    To study afternoon serum-melatonin values in patients with sleep disordered breathing. Melatonin has a strong circadian rhythm with high values during the night-time and low values in the afternoon. Sleep disordered breathing may change the circadian rhythm of melatonin which may have diagnostic implications. The Sleep Laboratory, The Department of Internal Medicine, Avesta Hospital, Sweden, and the Department of Anaesthesiology, Glostrup University Hospital, Copenhagen, Denmark. We examined 60 consecutive patients admitted for sleep disordered breathing and 10 healthy non snoring controls. The patients underwent a sleep apnoea screening test having a specificity of 100% for the obstructive sleep apnoea syndrome (OSAS) using a combination of static charge sensitive bed and oximetry. Obstructive sleep apnoea syndrome was found in 49 patients, eight patients had borderline sleep disordered breathing (BSDB) and three patients were excluded due to interfering disease. Patients and controls had an afternoon determination of serum-melatonin. The Epworth Sleepiness Scale was used to score day-time sleepiness. In comparison with normal controls patients suffering from OSAS had significantly higher serum-melatonin levels in the afternoon. However, as a diagnostic test for OSAS in patients with sleep disordered breathing serum-melatonin showed a low sensitivity but a high specificity. The results indicate that breathing disorders during sleep in general affect pineal function. Sleep disordered breathing seems to disturb pineal function. Determination of afternoon serum-melatonin alone or together with a scoring of daytime sleepiness does not identify OSAS-patients in a heterogeneous population of patients complaining of heavy snoring and excessive daytime sleepiness.

  8. Effects of online cone-beam computed tomography with active breath control in determining planning target volume during accelerated partial breast irradiation.

    PubMed

    Li, Y; Zhong, R; Wang, X; Ai, P; Henderson, F; Chen, N; Luo, F

    2017-04-01

    To test if active breath control during cone-beam computed tomography (CBCT) could improve planning target volume during accelerated partial breast radiotherapy for breast cancer. Patients who were more than 40 years old, underwent breast-conserving dissection and planned for accelerated partial breast irradiation, and with postoperative staging limited to T1-2 N0 M0, or postoperative staging T2 lesion no larger than 3cm with a negative surgical margin greater than 2mm were enrolled. Patients with lobular carcinoma or extensive ductal carcinoma in situ were excluded. CBCT images were obtained pre-correction, post-correction and post-treatment. Set-up errors were recorded at left-right, anterior-posterior and superior-inferior directions. The differences between these CBCT images, as well as calculated radiation doses, were compared between patients with active breath control or free breathing. Forty patients were enrolled, among them 25 had active breath control. A total of 836 CBCT images were obtained for analysis. CBCT significantly reduced planning target volume. However, active breath control did not show significant benefit in decreasing planning target volume margin and the doses of organ-at-risk when compared to free breathing. CBCT, but not active breath control, could reduce planning target volume during accelerated partial breast irradiation. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  9. Affective brain areas and sleep disordered breathing

    PubMed Central

    Harper, Ronald M.; Kumar, Rajesh; Macey, Paul M.; Woo, Mary A.; Ogren, Jennifer A.

    2014-01-01

    The neural damage accompanying the hypoxia, reduced perfusion, and other consequences of sleep-disordered breathing found in obstructive sleep apnea, heart failure (HF), and congenital central hypoventilation syndrome (CCHS), appears in areas that serve multiple functions, including emotional drives to breathe, and involve systems that serve affective, cardiovascular, and breathing roles. The damage, assessed with structural magnetic resonance imaging (MRI) procedures, shows tissue loss or water content and diffusion changes indicative of injury, and impaired axonal integrity between structures; damage is preferentially unilateral. Functional MRI responses in affected areas also are time- or amplitude- distorted to ventilatory or autonomic challenges. Among the structures injured are the insular, cingulate, and ventral medial prefrontal cortices, as well as cerebellar deep nuclei and cortex, anterior hypothalamus, raphé, ventrolateral medulla, basal ganglia and, in CCHS, the locus coeruleus. Raphé and locus coeruleus injury may modify serotonergic and adrenergic modulation of upper airway and arousal characteristics. Since both axons and gray matter show injury, the consequences to function, especially to autonomic, cognitive, and mood regulation, are major. Several affected rostral sites, including the insular and cingulate cortices and hippocampus, mediate aspects of dyspnea, especially in CCHS, while others, including the anterior cingulate and thalamus, participate in initiation of inspiration after central breathing pauses, and the medullary injury can impair baroreflex and breathing control. The ancillary injury associated with sleep-disordered breathing to central structures can elicit multiple other distortions in cardiovascular, cognitive, and emotional functions in addition to effects on breathing regulation. PMID:24746053

  10. Comparison and reproducibility of ADC measurements in breathhold, respiratory triggered, and free-breathing diffusion-weighted MR imaging of the liver.

    PubMed

    Kwee, Thomas C; Takahara, Taro; Koh, Dow-Mu; Nievelstein, Rutger A J; Luijten, Peter R

    2008-11-01

    To compare and determine the reproducibility of apparent diffusion coefficient (ADC) measurements of the normal liver parenchyma in breathhold, respiratory triggered, and free-breathing diffusion-weighted magnetic resonance imaging (DWI). Eleven healthy volunteers underwent three series of DWI. Each DWI series consisted of one breathhold, one respiratory triggered, and two free-breathing (thick and thin slice acquisition) scans of the liver, at b-values of 0 and 500 s/mm2. ADCs of the liver parenchyma were compared by using nonparametric tests. Reproducibility was assessed by the Bland-Altman method. Mean ADCs (in 10(-3) mm2/sec) in respiratory triggered DWI (2.07-2.27) were significantly higher than mean ADCs in breathhold DWI (1.57-1.62), thick slice free-breathing DWI (1.62-1.65), and thin slice free-breathing DWI (1.57-1.66) (P<0.005). Ranges of mean difference in ADC measurement+/-limits of agreement between two scans were -0.02-0.05+/-0.16-0.24 in breathhold DWI, -0.14-0.20+/-0.59-0.60 in respiratory triggered DWI, -0.03-0.03+/-0.20-0.29 in thick slice free-breathing DWI, and -0.01-0.09+/-0.21-0.29 in thin slice free-breathing DWI. ADC measurements of the normal liver parenchyma in respiratory triggered DWI are significantly higher and less reproducible than in breathhold and free-breathing DWI. Copyright (c) 2008 Wiley-Liss, Inc.

  11. The distribution of mitochondria-rich cells in the gills of air-breathing fishes.

    PubMed

    Lin, Hui-Chen; Sung, Wen-Ting

    2003-01-01

    Respiration and ion regulation are the two principal functions of teleostean gills. Mainly found in the gill filaments of fish, mitochondria-rich cells (MRCs) proliferate to increase the ionoregulatory capacity of the gill in response to osmotic challenges. Gill lamellae consist mostly of pavement cells, which are the major site of gas exchange. Although lamellar MRCs have been reported in some fish species, there has been little discussion of which fish species are likely to have lamellar MRCs. In this study, we first compared the number of filament and lamellar MRCs in air-breathing and non-air-breathing fish species acclimated to freshwater and 5 g NaCl L(-1) conditions. An increase in filament MRCs was found in both air-breathing and non-air-breathing fish acclimated to freshwater. Lamellar MRCs were found only in air-breathing species, but the number of lamellar MRCs did not change significantly with water conditions, except in Periophthalmus cantonensis. Next, we surveyed the distribution of MRCs in the gills of 66 fish species (including 29 species from the previous literature) from 12 orders, 28 families, and 56 genera. Our hypothesis that lamellar MRCs are more likely to be found in air-breathing fishes was supported by a significant association between the presence of lamellar MRCs and the mode of breathing at three levels of systematic categories (species, genus, and family). Based on this integrative view of the multiple functions of fish gills, we should reexamine the role of MRCs in freshwater fish.

  12. EVALUATION OF METHYL TERT-BUTYL ETHER (MTBE) AS AN INTERFERENCE ON COMMERCIAL BREATH-ALCOHOL ANALYZERS

    EPA Science Inventory

    Anecdotal reports suggest that high environmental or occupational exposures to the fuel oxygenate methyl tert-butyl ether (MTBE) may result in breath concentrations that are sufficiently elevated to cause a false positive on commercial breath-alcohol analyzers. We evaluated th...

  13. Variability of exhaled breath condensate (EBC) volume and pH using a feedback regulated breathing pattern

    EPA Science Inventory

    Exhaled breath condensate (EBC) is a valuable biological medium for non-invasively measuring biomarkers with the potential to reflect organ systems responses to environmental and dietary exposures and disease processes. Collection of EBC has typically been with spontaneous breat...

  14. [Application of the breath hydrogen test in gastroenterology].

    PubMed

    Loranskaia, I D; Panina, N A; Zheltakova, O V

    2006-01-01

    The diagnostic capacities of the breath hydrogen test in gastroenterology are discussed in the article. The authors describe the results of their own research--determination of the intestinal bacterial contamination in patients with chronic biliary pancreatitis with the help of the Micro H2 breath hydrogen analyzer.

  15. RECENT DEVELOPMENTS IN EXHALED BREATH ANALYSIS AND HUMAN EXPOSURE RESEARCH

    EPA Science Inventory

    Exhaled breath collection and analysis has historically been used in environmental research studies to characterize exposures to volatile organic compounds. The use of this approach is based on the fact that many compounds present in blood are reflected in the breath, and that u...

  16. Tenth anniversary special issue of the Journal of Breath Research: looking forward

    EPA Science Inventory

    The Journal of Breath Research has now reached its 10th anniversary of publication. From the general public’s perspective, breath analysis had always revolved around drinking and driving, and to some lesser extent pulmonary function testing of athletes. However, at the ince...

  17. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... taken at the connection point to the distribution system— (1) Every 6 months; and (2) After every repair or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked before... commencement of diving operations, at the umbilical or underwater breathing apparatus connection point for the...

  18. 78 FR 20137 - Certain Sleep-Disordered Breathing Treatment Systems and Components Thereof; Notice of Receipt of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-03

    ... INTERNATIONAL TRADE COMMISSION [Docket No. 2948] Certain Sleep-Disordered Breathing Treatment... given that the U.S. International Trade Commission has received a complaint entitled Certain Sleep... United States after importation of certain sleep- disordered breathing treatment systems and components...

  19. Analysis of breath volatile organic compounds as a screening tool for detection of Tuberculosis in cattle

    USDA-ARS?s Scientific Manuscript database

    • Keywords: bovine tuberculosis; Mycobacterium bovis; breath analysis; volatile organic compound; gas chromatography; mass spectrometry; NaNose • Introduction: This presentation describes two studies exploring the use of breath VOCs to identify Mycobacterium bovis infection in cattle. • Methods: ...

  20. 21 CFR 868.5965 - Positive end expiratory pressure breathing attachment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... in a patient's lungs above atmospheric pressure at the end of exhalation. (b) Classification. Class... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Positive end expiratory pressure breathing... Positive end expiratory pressure breathing attachment. (a) Identification. A positive end expiratory...

Top