Sample records for breathing apparatus scuba

  1. Provisional report on diving-related fatalities in Australian waters 2004.

    PubMed

    Walker, Douglas; Lippmann, John; Lawrence, Chris; Huston, John; Fock, Andrew

    2009-09-01

    An individual case review of diving-related deaths reported to have occurred in Australia in 2004 was conducted as part of the DAN Asia-Pacific dive fatality reporting project. The case studies were compiled using reports from witnesses, the police and coroners. In each case, the particular circumstances of the accident are provided, and also details from the post-mortem examination, where available. In total, there were 22 reported fatalities, all male. Nine deaths occurred while snorkelling and/or breath-hold diving, 10 while scuba diving, one just prior to scuba diving, one while using surface-supply breath apparatus and one while diving with a rebreather. In this series, cardiac-related issues were thought to have contributed to the deaths of five snorkel divers and three scuba divers, and in one person who was about to go diving. Three of the deaths in breath-hold divers were likely to have been associated with apnoeic hypoxia blackout. Pre-existing medical conditions, inexperience, time away from diving, inadequate supervision, and diving without appropriate training were features in several scuba deaths in this series.

  2. Provisional report on diving-related fatalities in Australian waters 2003.

    PubMed

    Walker, Douglas; Lippmann, John

    2009-03-01

    An individual case review of the diving-related deaths that were reported to have occurred in Australia in 2003 was conducted as part of the combined Project Stickybeak/DAN Asia-Pacific dive fatality reporting project. The case studies were compiled using reports from witnesses, the police and coroners. In each case, the particular circumstances of the accident are provided, as well as details from the post mortem examination, where available. In total there were 22 reported fatalities, 18 men and four women. Twelve deaths occurred while snorkelling and/or breath-hold diving, nine while scuba diving and one while using surface-supply breathing apparatus. Cardiac-related issues were thought to have contributed to the deaths of six snorkel divers (50%) and four scuba divers (44%) in this series. There were three deaths in breath-hold divers likely to have been associated with apnoeic hypoxia blackout. Inexperience, time away from diving and lack of common sense were features in several scuba deaths.

  3. 50 CFR 32.72 - Guam.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Contained Underwater Breathing Apparatus (SCUBA) to take fish or invertebrates. 6. We prohibit anchoring... Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE NATIONAL.... [Reserved] C. Big Game Hunting. [Reserved] D. Sport Fishing. Anglers may fish and collect marine life on...

  4. Provisional report on diving-related fatalities in Australian waters 2005.

    PubMed

    Walker, Douglas; Lippmann, John; Lawrence, Chris; Fock, Andrew; Wodak, Thomas; Jamieson, Scott

    2010-09-01

    An individual case review of diving-related deaths reported as occurring in Australia in 2005 was conducted as part of the DAN Asia-Pacific dive fatality reporting project. The case studies were compiled using reports from witnesses, the police and coroners. In each case, the particular circumstances of the accident and details from the post-mortem examination, where available, are provided. In total, there were 24 reported fatalities, comprising four females and 20 males. Fourteen deaths occurred while snorkelling and/or breath-hold diving, nine while scuba diving, and one while using surface-supply breathing apparatus. Four deaths from large marine animal attacks were recorded. Once again, cardiac-related issues were thought to have contributed to some deaths: five snorkel divers and at least two but possibly up to four scuba divers. Three of the deaths in breath-hold divers were likely to have been associated with apnoeic hypoxia blackout. Pre-existing medical conditions, trauma from marine creatures and snorkelling or diving alone were features in several deaths in this series.

  5. Design and Validation of a Breathing Detection System for Scuba Divers.

    PubMed

    Altepe, Corentin; Egi, S Murat; Ozyigit, Tamer; Sinoplu, D Ruzgar; Marroni, Alessandro; Pierleoni, Paola

    2017-06-09

    Drowning is the major cause of death in self-contained underwater breathing apparatus (SCUBA) diving. This study proposes an embedded system with a live and light-weight algorithm which detects the breathing of divers through the analysis of the intermediate pressure (IP) signal of the SCUBA regulator. A system composed mainly of two pressure sensors and a low-power microcontroller was designed and programmed to record the pressure sensors signals and provide alarms in absence of breathing. An algorithm was developed to analyze the signals and identify inhalation events of the diver. A waterproof case was built to accommodate the system and was tested up to a depth of 25 m in a pressure chamber. To validate the system in the real environment, a series of dives with two different types of workload requiring different ranges of breathing frequencies were planned. Eight professional SCUBA divers volunteered to dive with the system to collect their IP data in order to participate to validation trials. The subjects underwent two dives, each of 52 min on average and a maximum depth of 7 m. The algorithm was optimized for the collected dataset and proved a sensitivity of inhalation detection of 97.5% and a total number of 275 false positives (FP) over a total recording time of 13.9 h. The detection algorithm presents a maximum delay of 5.2 s and requires only 800 bytes of random-access memory (RAM). The results were compared against the analysis of video records of the dives by two blinded observers and proved a sensitivity of 97.6% on the data set. The design includes a buzzer to provide audible alarms to accompanying dive buddies which will be triggered in case of degraded health conditions such as near drowning (absence of breathing), hyperventilation (breathing frequency too high) and skip-breathing (breathing frequency too low) measured by the improper breathing frequency. The system also measures the IP at rest before the dive and indicates with flashing light-emitting diodes and audible alarm the regulator malfunctions due to high or low IP that may cause fatal accidents during the dive by preventing natural breathing. It is also planned to relay the alarm signal to underwater and surface rescue authorities by means of acoustic communication.

  6. Provisional report on diving-related fatalities in Australian waters 2008.

    PubMed

    Lippmann, John; Walker, Douglas; Lawrence, Chris; Fock, Andrew; Wodak, Thomas; Harris, Richard; Jamieson, Scott

    2013-03-01

    An individual case review of diving-related deaths, reported as occurring in Australia in 2008, was conducted as part of the DAN Asia-Pacific dive fatality reporting project. The case studies were compiled using reports from witnesses, the police and coroners. In each case, the particular circumstances of the accident and details from the post-mortem examination, where available, are provided. In total, there were 19 reported fatalities (the same as for 2007), 17 involving males. Twelve deaths occurred while snorkelling and/or breath-hold diving,and six while scuba diving. One diver died while using surface-supply breathing apparatus. Two breath-hold divers appear to have died as a result of apnoeic hypoxia, at least one case likely associated with hyperventilation. Two deaths resulted from trauma: one from impact with a boat and the other from an encounter with a great white shark. Cardiac-related issues were thought to have contributed to the deaths of five snorkellers and at least two, possibly three, scuba divers. Trauma from a marine creature, snorkelling or diving alone, apnoeic hypoxia and pre-existing medical conditions were once again features in several deaths in this series.

  7. Microcontroller-based underwater acoustic ECG telemetry system.

    PubMed

    Istepanian, R S; Woodward, B

    1997-06-01

    This paper presents a microcontroller-based underwater acoustic telemetry system for digital transmission of the electrocardiogram (ECG). The system is designed for the real time, through-water transmission of data representing any parameter, and it was used initially for transmitting in multiplexed format the heart rate, breathing rate and depth of a diver using self-contained underwater breathing apparatus (SCUBA). Here, it is used to monitor cardiovascular reflexes during diving and swimming. The programmable capability of the system provides an effective solution to the problem of transmitting data in the presence of multipath interference. An important feature of the paper is a comparative performance analysis of two encoding methods, Pulse Code Modulation (PCM) and Pulse Position Modulation (PPM).

  8. Are recreational SCUBA divers with asthma at increased risk?

    PubMed

    Ustrup, Amalie S; Ulrik, Charlotte S

    2017-10-01

    Asthma has traditionally been regarded as a contraindication to self-contained underwater breathing apparatus (SCUBA) diving, although large numbers of patients with asthma dive. The aim of the review is to provide an update on current knowledge on potential disease-related hazards in SCUBA divers with asthma. Systematic literature review based on the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Seven studies met the criteria for inclusion in the review (comprising a total of 560 subjects). Five studies reported an increased risk for developing diving-related injuries in divers with asthma, based on case reports (n = 1), case history combined with objective assessment (n = 1), and dives and/or simulated dives (n = 3). The remaining studies (n = 2) were based on self-reported diving habits in divers suffering from asthma, obtained from anonymous questionnaires in diving magazines, reported no diving-related injuries among respondents. Due to limited evidence it is difficult to draw valid conclusions, but there are indications that recreational divers with asthma may be at increased risk for diving-related injuries compared to non-asthmatic divers. However, it is of at most importance to obtain further evidence from large-scale, well-designed studies.

  9. Preparations for Underwater EVA training for the STS 41-G crew

    NASA Image and Video Library

    1984-07-05

    S84-36900 (29 June 1984) ---Astronauts Robert L. Crippen (right) and Jon A. McBride, crew commander and pilot, respectively, for NASA's 41-G Space Shuttle mission, don self contained underwater breathing apparatus (SCUBA) gear prior to their underwater to observe a simulation of an extravehicular activity (EVA) to be performed on their mission. Astronauts Kathryn D. Sullivan and David C. Leestma, two of three mission specialists on the seven-member crew, are scheduled for the EVA. The underwater training took place in the Johnson Space Center's weightless environment training facility (WET-F).

  10. Provisional report on diving-related fatalities in Australian waters in 2011.

    PubMed

    Lippmann, John; Lawrence, Christopher; Fock, Andrew; Jamieson, Scott; Harris, Richard

    2016-12-01

    An individual case review of diving-related deaths reported as occurring in Australia in 2011 was conducted as part of the DAN Asia-Pacific dive fatality reporting project. The case studies were compiled using reports from witnesses, the police and coroners. In each case, the particular circumstances of the accident and, where available, details from the post-mortem examination are provided. A chain of events analysis was conducted for each case. In total, there were 30 reported fatalities (10 more than in 2010). These included 15 snorkel/breath-hold divers, 14 scuba divers and one diver using surface-supplied breathing apparatus. Twenty-four victims were males. The mean age of snorkelling victims was 49.6 (range 23-75) years and compressed gas divers 42.2 (range 23-55) years. Cardiac-related issues were thought to have been the disabling injury in the deaths of at least seven snorkel divers and five scuba divers. Immersion pulmonary oedema was implicated in at least one death; and three fatalities resulted from attacks by marine animals. Two novices died while under instruction/supervision after separation from their instructor in poor visibility. Pre-existing medical conditions, separation and inadequate supervision and seafood collection in areas frequented by marine predators were once again features in several deaths in this series.

  11. Introduction of a compressed air breathing apparatus for the offshore oil and gas industry.

    PubMed

    Brooks, Chris J; MacDonald, Conor V; Carroll, Joel; Gibbs, Peter N G

    2010-07-01

    When a helicopter ditches the majority of crew and passengers have to make an underwater escape. Some may not be able to hold their breath and will drown. For at least 15 yr, military aircrew have been trained to use a scuba system. In the offshore oil and gas industry, there has been more caution about introducing a compressed air system and a rebreather system has been introduced as an alternative. Recently, Canadian industry and authorities approved the introduction of Helicopter Underwater Emergency Breathing Apparatus (HUEBA) training using compressed air. This communication reports the training of the first 1000 personnel. Training was introduced in both Nova Scotia and Newfoundland concurrently by the same group of instructors. Trainees filled out a questionnaire concerning their perceived ratings of the ease or difficulty of classroom training and the practical use of the HUEBA. Ninety-eight percent of trainees found the classroom and in-water training to be "good/very good". Trainees found it to be "easy/very easy" to clear the HUEBA and breathe underwater in 84% and 64% of cases, respectively. Divers reported a greater ease in learning all the practical uses of the HUEBA except application of the nose clip. There were problems with the nose clip fitting incorrectly, and interference of the survival suit hood with the regulator, which subsequently have been resolved. When carefully applied, the introduction of the HUEBA into training for offshore oil and gas industry helicopter crew and passengers can be safely conducted.

  12. Evaluation of Contaminant-Promoted Ignition in Scuba Equipment and Breathing Gas Delivery Systems

    NASA Technical Reports Server (NTRS)

    Forsyth, Elliott T.; Durkin, Robert; Beeson, Harold D.

    2000-01-01

    As the underwater diving industry continues to use greater concentrations of oxygen in their scuba systems, ignition of contaminants in these systems becomes a greater concern. Breathing gas makeup and distribution systems typically combine pure oxygen with various diluents to supply high-pressure cylinders for scuba applications. The hazards associated with these applications of oxygen and NITROX (oxygen and nitrogen mixture) gases require an evaluation of inherent contaminant levels and their associated promoted-ignition thresholds in these environments. In this study, several scuba component assemblies were tested after one year of use at the NASA Johnson Space Center Neutral Buoyancy Lab. The components were rapidly impacted with 50% NITROX gas to demonstrate their ignition resistance, then disassembled to evaluate their cleanliness. A follow-up study was then performed on the ignition thresholds of hydrocarbon-bascd oil films in oxygen and NITROX environments in an attempt to define the cleaning requirements for these systems. Stainless steel tubes were contaminated and verified to known levels and placed in a pneumatic impact test system where they were rapidly pressurized with the test gas. Ignitions were determined using a photodiode connected to the end of the contaminated tube. The results of the scuba component tests, cleanliness evaluation, and contaminant ignition study are discussed and compared for 50% NITROX and 100% oxygen environments.

  13. 29 CFR 1910.424 - SCUBA diving.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... OCCUPATIONAL SAFETY AND HEALTH STANDARDS Commercial Diving Operations Specific Operations Procedures § 1910.424... physically confining spaces. (4) A diver-carried reserve breathing gas supply shall be provided for each... breathing gas supply shall be in the closed position prior to the dive. ...

  14. 46 CFR 197.346 - Diver's equipment.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... using SCUBA must have— (1) Self-contained underwater breathing equipment including— (i) A primary..., gloves, shoes, weight assembly, and knife; (3) Have a hose group consisting of the breathing gas hose and... assembly capable of quick release; (3) A mask group consisting of a lightweight mask and associated valves...

  15. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Self-contained breathing apparatus; description. 84...-Contained Breathing Apparatus § 84.70 Self-contained breathing apparatus; description. (a) Self-contained breathing apparatus, including all completely assembled, portable, self-contained devices designed for use...

  16. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Self-contained breathing apparatus; description. 84...-Contained Breathing Apparatus § 84.70 Self-contained breathing apparatus; description. (a) Self-contained breathing apparatus, including all completely assembled, portable, self-contained devices designed for use...

  17. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS... 46 Shipping 3 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78...

  18. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Self-contained breathing apparatus; required...-Contained Breathing Apparatus § 84.71 Self-contained breathing apparatus; required components. (a) Each self-contained breathing apparatus described in § 84.70 shall, where its design requires, contain the following...

  19. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Self-contained breathing apparatus; required...-Contained Breathing Apparatus § 84.71 Self-contained breathing apparatus; required components. (a) Each self-contained breathing apparatus described in § 84.70 shall, where its design requires, contain the following...

  20. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF-CONTAINED BREATHING APPARATUS... 46 Shipping 3 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78...

  1. Two fatal cases of immersion pulmonary oedema - using dive accident investigation to assist the forensic pathologist.

    PubMed

    Smart, David R; Sage, Martin; Davis, F Michael

    2014-06-01

    Immersion pulmonary oedema (IPE) is being increasingly recognized in swimmers, snorkellers and scuba divers presenting with acute symptoms of respiratory distress following immersion, but fatal case reports are uncommon. We report two fatal cases of probable IPE in middle-aged women, one whilst snorkelling and the other associated with a scuba dive. In the snorkeller's case, an episode of exercise-related chest tightness and shortness of breath that occurred 10 months previously was investigated but this proved negative, and she was on no medications. However, at autopsy, moderate left ventricular hypertrophy was noted. The scuba diver had suffered several previous episodes of severe shortness of breath following dives, one being so severe it led to cyanosis and impaired consciousness. At inquest, the pathologist's diagnosis was given as drowning and IPE was not mentioned. Expert input from doctors trained in diving medicine should be compulsory in the investigation of diving deaths, and forensic pathologists should be properly trained in and have guidelines for the conduct of post-immersion and post-diving autopsies.

  2. Breath-holding ability of offshore workers inadequate to ensure escape from ditched helicopters.

    PubMed

    Cheung, S S; D'Eon, N J; Brooks, C J

    2001-10-01

    Following a helicopter ditching in water, the survival rate of individuals not mortally injured by the impact ranges from 50-85%. One possible cause for this low survival rate is that the crew and passengers cannot hold their breath underwater long enough to make the often difficult escape from an inverted and submerged helicopter. We investigated pulmonary function, breath-holding times in air (BHTa) and water (BHTw) of 228 students enrolled in offshore survival courses required to work in either the offshore petroleum industry or in military marine aviation. Comparisons were performed based on occupation, SCUBA experience, and smoking. In 25 degrees C pool water, the overall BHTw ranged from 5.4 to 120 s with a median of 37 s. Of the 228 subjects, 34% had a BHTw less than the 28 s required for the complete evacuation of a Super Puma helicopter under ideal conditions. No significant differences in BHTw were observed based on either smoking history (Non-Smoker, 41.5 +/- 21.6 s; Smoker, 37.2 +/- 20.2 s) or occupation (Novice, 37.5 +/- 21.1 s; Offshore, 40.5 +/- 21.1 s; Military, 45.2 +/- 20.9 s). However, SCUBA-trained individuals had a significantly longer BHT, (47.4 +/- 21.6 s) than non-SCUBA (37.6 +/- 20.6 s), as well as a greater force vital capacity (FVC), BHTa, and subjective comfort in water. It is concluded that the inability to breath-hold in emergency situations is a major contributor to the low survival rates of marine helicopter ditchings. Therefore, efforts must be made to both decrease escape times and to increase survival time underwater.

  3. 77 FR 37862 - Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-25

    ...; NIOSH-258] Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance... open-circuit self-contained breathing apparatus (OC- SCBA) remaining service-life indicators... ``Open-Circuit Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance...

  4. 75 FR 61386 - Emergency Escape Breathing Apparatus Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-05

    ...-0044, Notice No. 1] RIN 2130-AC14 Emergency Escape Breathing Apparatus Standards AGENCY: Federal... breathing apparatus (EEBA) to the members of the train crew and certain other employees while they are... EEBA--emergency escape breathing apparatus FRA--Federal Railroad Administration FRSA--the former...

  5. 46 CFR 108.635 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 108.635 Section 108...

  6. 78 FR 2618 - Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-14

    ... 0920-AA38 Self-Contained Breathing Apparatus Remaining Service-Life Indicator Performance Requirements... requirements for self-contained breathing apparatus (SCBA) remaining service-life indicators or warning devices... self-contained breathing apparatus (SCBA) used in the fire service, and a firefighters' union. A...

  7. 46 CFR 108.635 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DESIGN AND EQUIPMENT Equipment Markings and Instructions § 108.635 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked: “SELF CONTAINED... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.635 Section 108...

  8. 46 CFR 195.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  9. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the following devices: (a) Two pressure-demand, open circuit, self-contained breathing apparatus, approved by...

  10. 46 CFR 195.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 195.30-15 Section... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 195.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  11. 46 CFR 108.703 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 108.703 Section 108...

  12. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  13. 46 CFR 97.37-20 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 97.37-20 Section 97... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-20 Self-contained breathing apparatus. (a) Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF...

  14. 46 CFR 169.736 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  15. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the following devices: (a) Two pressure-demand, open circuit, self-contained breathing apparatus, approved by...

  16. 46 CFR 108.703 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... DESIGN AND EQUIPMENT Miscellaneous Equipment § 108.703 Self-contained breathing apparatus. (a) Each unit must be equipped with a self-contained breathing apparatus described in § 108.497(a) to use as... 46 Shipping 4 2010-10-01 2010-10-01 false Self-contained breathing apparatus. 108.703 Section 108...

  17. 46 CFR 96.30-15 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 96.30-15 Section 96... VESSELS VESSEL CONTROL AND MISCELLANEOUS SYSTEMS AND EQUIPMENT Protection From Refrigerants § 96.30-15 Self-contained breathing apparatus. (a) Each vessel must have a self-contained breathing apparatus for...

  18. 46 CFR 169.736 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 169.736 Section 169... VESSELS Vessel Control, Miscellaneous Systems, and Equipment Markings § 169.736 Self-contained breathing apparatus. Each locker or space containing self-contained breathing apparatus must be marked “SELF-CONTAINED...

  19. 46 CFR 97.37-20 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Self-contained breathing apparatus. 97.37-20 Section 97... VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-20 Self-contained breathing apparatus. (a) Lockers or spaces containing self-contained breathing apparatus shall be marked “SELF...

  20. 30 CFR 57.22315 - Self-contained breathing apparatus (V-A mines).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Self-contained breathing apparatus (V-A mines... NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22315 Self-contained breathing apparatus (V-A mines). Self-contained breathing apparatus of a duration to allow for escape from...

  1. 46 CFR 196.37-20 - Self-contained breathing apparatus and gas masks.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Self-contained breathing apparatus and gas masks. 196.37... RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-20 Self-contained breathing apparatus and gas masks. (a) Lockers or spaces containing self-contained breathing apparatus shall...

  2. 46 CFR 196.37-20 - Self-contained breathing apparatus and gas masks.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 7 2011-10-01 2011-10-01 false Self-contained breathing apparatus and gas masks. 196.37... RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-20 Self-contained breathing apparatus and gas masks. (a) Lockers or spaces containing self-contained breathing apparatus shall...

  3. 46 CFR 28.205 - Fireman's outfits and self-contained breathing apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 1 2011-10-01 2011-10-01 false Fireman's outfits and self-contained breathing apparatus... the Aleutian Trade § 28.205 Fireman's outfits and self-contained breathing apparatus. (a) Each vessel... equipped with at least two self-contained breathing apparatuses. (c) A fireman's outfit must consist of one...

  4. 30 CFR 57.22315 - Self-contained breathing apparatus (V-A mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Self-contained breathing apparatus (V-A mines... NONMETAL MINES Safety Standards for Methane in Metal and Nonmetal Mines Equipment § 57.22315 Self-contained breathing apparatus (V-A mines). Self-contained breathing apparatus of a duration to allow for escape from...

  5. 46 CFR 28.205 - Fireman's outfits and self-contained breathing apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Fireman's outfits and self-contained breathing apparatus... the Aleutian Trade § 28.205 Fireman's outfits and self-contained breathing apparatus. (a) Each vessel... equipped with at least two self-contained breathing apparatuses. (c) A fireman's outfit must consist of one...

  6. Increasing the probability of surviving loss of consciousness underwater when using a rebreather.

    PubMed

    Haynes, Paul

    2016-12-01

    Re-circulating underwater breathing apparatus (rebreathers) have become increasingly popular amongst sport divers. In comparison to open-circuit scuba, rebreathers are complex life support equipment that incorporates many inherent failure modes and potential for human error. This individually or in combination can lead to an inappropriate breathing gas. Analysis of rebreather diving incidents suggests that inappropriate breathing gas is the most prevalent disabling agent. This can result in spontaneous loss of consciousness (LoC), water aspiration and drowning. Protecting the airway by maintaining the diver/rebreather oral interface may delay water aspiration following LoC underwater; the possibility of a successful rescue is, thus, increased. One means of protecting the airway following LoC underwater is the use of a full-face mask (FFM). However, such masks are complex and expensive; therefore, they have not been widely adopted by the sport diving community. An alternative to the FFM used extensively throughout the global military diving community is the mouthpiece retaining strap (MRS). A recent study documented 54 LoC events in military rebreather diving with only three consequent drownings; all divers were reported to be using a MRS. Even allowing for the concomitant use of a tethered diving partner system in most cases, the low number of fatalities in this large series is circumstantially supportive of the efficacy of the MRS. Despite drowning featuring as a final common pathway in the vast majority of rebreather fatalities, the MRS has not been widely adopted by the sport rebreather diving community.

  7. Arterial stress hormones during scuba diving with different breathing gases.

    PubMed

    Weist, Frank; Strobel, Günther; Hölzl, Mathias; Böning, Dieter

    2012-07-01

    The purpose of the study was to determine whether the conditions during scuba diving without exercise (e.g., submersion, restricted breathing) stimulate the activities of the sympathoadrenergic system and the hypothalamic-pituitary-adrenal axis. This might facilitate panic reactions in dangerous situations. Fifteen experienced rescue divers participated in three experiments with two submersions each in a diving tower where ambient pressure could be varied. During submersion (duration = 15 min), they were breathing either pure oxygen (ambient pressure = 1.1 bar) or air (1.1 and 5.3 bar) or Heliox21 (21% O(2) and 79% He, 1.1 and 5.3 bar). The subjects stayed upright immediately below the water surface holding one hand with a cannulated radial artery out in the air. Noradrenaline, adrenaline, and dopamine concentrations in arterial blood and heart rate (HR) variability as indicators of sympathoadrenergic activity and cortisol and adrenocorticotropic hormone concentrations as strain indicators were measured. [Noradrenaline] and [adrenaline] (initial values (mean ± SE) = 1616 ± 93 and 426 ± 38 pmol·L(-1)) decreased significantly by up to 30% and 50%, respectively, after 11 min of submersion, independent of pressure and inspired gas. HR variability showed roughly corresponding changes and also indications for parasympathetic stimulation, but artifacts by interference among HR monitors reduced the number of usable measurements. The other hormone concentrations did not change significantly. There was no increase of stress hormone concentrations in experienced subjects. The reduction of [noradrenaline] and [adrenaline] during scuba diving seems to be a reaction to orthostatic relief caused by external hydrostatic pressure on peripheral vasculature. The activity of the vegetative nervous system might be estimated from HR variability if interference among pulse watches can be avoided.

  8. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be...) Containers supplied by the applicant for carrying or storing self-contained breathing apparatus will be...

  9. 42 CFR 84.74 - Apparatus containers; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Apparatus containers; minimum requirements. 84.74...-Contained Breathing Apparatus § 84.74 Apparatus containers; minimum requirements. (a) Apparatus may be...) Containers supplied by the applicant for carrying or storing self-contained breathing apparatus will be...

  10. The impact of consecutive freshwater trimix dives at altitude on human cardiovascular function.

    PubMed

    Lozo, Mislav; Madden, Dennis; Gunjaca, Grgo; Ljubkovic, Marko; Marinovic, Jasna; Dujic, Zeljko

    2015-03-01

    Self-contained underwater breathing apparatus (SCUBA) diving is regularly associated with numerous asymptomatic changes in cardiovascular function. Freshwater SCUBA diving presents unique challenges compared with open sea diving related to differences in water density and the potential for dive locations at altitude. The aim of this study was to evaluate the impact of freshwater trimix diving at altitude on human cardiovascular function. Ten divers performed two dives in consecutive days at 294 m altitude with the surface interval of 24 h. Both dives were at a depth of 45 m with total dive time 29 and 26 min for the first and second dive, respectively. Assessment of venous gas embolization, hydration status, cardiac function and arterial stiffness was performed. Production of venous gas emboli was low, and there were no significant differences between the dives. After the first dive, diastolic blood pressure was significantly reduced, which persisted up to 24 h. Left ventricular stroke volume decreased, and heart rate increased after both dives. Pulse wave velocity was unchanged following the dives. However, the central and peripheral augmentation index became more negative after both dives, indicating reduced wave reflection. Ejection duration and round trip travel time were prolonged 24 h after the first dive, suggesting longer-lasting suppression of cardiac and endothelial function. This study shows that freshwater trimix dives with conservative profiles and low venous gas bubble loads can result in multiple asymptomatic acute cardiovascular changes some of which were present up to 24 h after dive. © 2014 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  11. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 3 2012-10-01 2012-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78.47-27 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or...

  12. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 3 2013-10-01 2013-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78.47-27 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or...

  13. 46 CFR 78.47-27 - Self-contained breathing apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 3 2014-10-01 2014-10-01 false Self-contained breathing apparatus. 78.47-27 Section 78.47-27 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-27 Self-contained breathing apparatus. Lockers or...

  14. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 7 2013-10-01 2013-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the... Officer in Charge, Marine Inspection. (b) One flame safety lamp approved by the Coast Guard or Navy. [CGD...

  15. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 7 2014-10-01 2014-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the... Officer in Charge, Marine Inspection. (b) One flame safety lamp approved by the Coast Guard or Navy. [CGD...

  16. 46 CFR 167.45-60 - Emergency breathing apparatus and flame safety lamps.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 7 2012-10-01 2012-10-01 false Emergency breathing apparatus and flame safety lamps... Emergency breathing apparatus and flame safety lamps. Each nautical-school ship must be equipped with the... Officer in Charge, Marine Inspection. (b) One flame safety lamp approved by the Coast Guard or Navy. [CGD...

  17. Beneficial effect of enriched air nitrox on bubble formation during scuba diving. An open-water study.

    PubMed

    Brebeck, Anne-Kathrin; Deussen, Andreas; Range, Ursula; Balestra, Costantino; Cleveland, Sinclair; Schipke, Jochen D

    2018-03-01

    Bubble formation during scuba diving might induce decompression sickness. This prospective randomised and double-blind study included 108 advanced recreational divers (38 females). Fifty-four pairs of divers, 1 breathing air and the other breathing nitrox28 undertook a standardised dive (24 ± 1 msw; 62 ± 5min) in the Red Sea. Venous gas bubbles were counted (Doppler) 30-<45 min (early) and 45-60 min (late) post-dive at jugular, subclavian and femoral sites. Only 7% (air) vs. 11% (air28®) (n.s.) were bubble-free after a dive. Independent of sampling time and breathing gas, there were more bubbles in the jugular than in the femoral vein. More bubbles were counted in the air-group than in the air28-group (pooled vein: early: 1845 vs. 948; P = 0.047, late: 1817 vs. 953; P = 0.088). The number of bubbles was sex-dependent. Lastly, 29% of female air divers but only 14% of male divers were bubble-free (P = 0.058). Air28® helps to reduce venous gas emboli in recreational divers. The bubble number depended on the breathing gas, sampling site and sex. Thus, both exact reporting the dive and in particular standardising sampling characteristics seem mandatory to compare results from different studies to further investigate the hitherto incoherent relation between inert gas bubbles and DCS.

  18. 42 CFR 84.96 - Service time test; closed-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...

  19. 42 CFR 84.96 - Service time test; closed-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; closed-circuit apparatus. 84.96...-Contained Breathing Apparatus § 84.96 Service time test; closed-circuit apparatus. (a) The closed-circuit apparatus will be classified according to the length of time it supplies adequate breathing gas to the...

  20. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...

  1. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be measured with a breathing machine as described in § 84.88. (b) The open-circuit apparatus will be...

  2. The Debreather: A Report on Euthanasia and Suicide Assistance Using Adapted Scuba Technology

    ERIC Educational Resources Information Center

    Ogden, Russel D.

    2010-01-01

    In response to the general prohibition of euthanasia and assisted suicide, some right-to-die activists have developed non-medical methods to covertly hasten death. One such method is a "debreather," a closed system breathing device that laypersons can use to induce hypoxia for persons seeking euthanasia or assisted suicide. This article presents…

  3. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2013-10-01 2013-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  4. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2012-10-01 2012-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  5. 42 CFR 84.95 - Service time test; open-circuit apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... classified according to the length of time it supplies air or oxygen to the breathing machine. (c) The... 42 Public Health 1 2014-10-01 2014-10-01 false Service time test; open-circuit apparatus. 84.95...-Contained Breathing Apparatus § 84.95 Service time test; open-circuit apparatus. (a) Service time will be...

  6. Apparatus and method for monitoring breath acetone and diabetic diagnostics

    DOEpatents

    Duan, Yixiang [Los Alamos, NM; Cao, Wenqing [Los Alamos, NM

    2008-08-26

    An apparatus and method for monitoring diabetes through breath acetone detection and quantitation employs a microplasma source in combination with a spectrometer. The microplasma source provides sufficient energy to produce excited acetone fragments from the breath gas that emit light. The emitted light is sent to the spectrometer, which generates an emission spectrum that is used to detect and quantify acetone in the breath gas.

  7. 30 CFR 49.16 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.16 Equipment and maintenance... team members. (1) Twelve self-contained breathing apparatus, each with a minimum of 4 hours capacity... apparatus and sufficient to sustain each team for 8 hours while using the breathing apparatus during rescue...

  8. 30 CFR 49.16 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.16 Equipment and maintenance... team members. (1) Twelve self-contained breathing apparatus, each with a minimum of 4 hours capacity... apparatus and sufficient to sustain each team for 8 hours while using the breathing apparatus during rescue...

  9. 30 CFR 49.16 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.16 Equipment and maintenance... team members. (1) Twelve self-contained breathing apparatus, each with a minimum of 4 hours capacity... apparatus and sufficient to sustain each team for 8 hours while using the breathing apparatus during rescue...

  10. 30 CFR 49.16 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.16 Equipment and maintenance... team members. (1) Twelve self-contained breathing apparatus, each with a minimum of 4 hours capacity... apparatus and sufficient to sustain each team for 8 hours while using the breathing apparatus during rescue...

  11. 30 CFR 49.16 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Coal Mines § 49.16 Equipment and maintenance... team members. (1) Twelve self-contained breathing apparatus, each with a minimum of 4 hours capacity... apparatus and sufficient to sustain each team for 8 hours while using the breathing apparatus during rescue...

  12. Compressed air demand-type firefighter's breathing system, volume 1. [design analysis and performance tests

    NASA Technical Reports Server (NTRS)

    Sullivan, J. L.

    1975-01-01

    The commercial availability of lightweight high pressure compressed air vessels has resulted in a lightweight firefighter's breathing apparatus. The improved apparatus, and details of its design and development are described. The apparatus includes a compact harness assembly, a backplate mounted pressure reducer assembly, a lightweight bubble-type facemask with a mask mounted demand breathing regulator. Incorporated in the breathing regulator is exhalation valve, a purge valve and a whistle-type low pressure warning that sounds only during inhalation. The pressure reducer assembly includes two pressure reducers, an automatic transfer valve and a signaling device for the low pressure warning. Twenty systems were fabricated, tested, refined through an alternating development and test sequence, and extensively examined in a field evaluation program. Photographs of the apparatus are included.

  13. Liquid-Air Breathing Apparatus

    NASA Technical Reports Server (NTRS)

    Mills, Robert D.

    1990-01-01

    Compact unit supplies air longer than compressed-air unit. Emergency breathing apparatus stores air as cryogenic liquid instead of usual compressed gas. Intended for firefighting or rescue operations becoming necessary during planned potentially hazardous procedures.

  14. Ascorbic acid supplementation diminishes microparticle elevations and neutrophil activation following SCUBA diving.

    PubMed

    Yang, Ming; Barak, Otto F; Dujic, Zeljko; Madden, Dennis; Bhopale, Veena M; Bhullar, Jasjeet; Thom, Stephen R

    2015-08-15

    Predicated on evidence that diving-related microparticle generation is an oxidative stress response, this study investigated the role that oxygen plays in augmenting production of annexin V-positive microparticles associated with open-water SCUBA diving and whether elevations can be abrogated by ascorbic acid. Following a cross-over study design, 14 male subjects ingested placebo and 2-3 wk later ascorbic acid (2 g) daily for 6 days prior to performing either a 47-min dive to 18 m of sea water while breathing air (∼222 kPa N2/59 kPa O2) or breathing a mixture of 60% O2/balance N2 from a tight-fitting face mask at atmospheric pressure for 47 min (∼40 kPa N2/59 kPa O2). Within 30 min after the 18-m dive in the placebo group, neutrophil activation, and platelet-neutrophil interactions occurred, and the total number of microparticles, as well as subgroups bearing CD66b, CD41, CD31, CD142 proteins or nitrotyrosine, increased approximately twofold. No significant elevations occurred among divers after ingesting ascorbic acid, nor were elevations identified in either group after breathing 60% O2. Ascorbic acid had no significant effect on post-dive intravascular bubble production quantified by transthoracic echocardiography. We conclude that high-pressure nitrogen plays a key role in neutrophil and microparticle-associated changes with diving and that responses can be abrogated by dietary ascorbic acid supplementation. Copyright © 2015 the American Physiological Society.

  15. A chlorate candle/lithium hydroxide personal breathing apparatus

    NASA Technical Reports Server (NTRS)

    Martin, F. E.

    1972-01-01

    A portable coal mine rescue and survival equipment is reported that consists of a chlorate candle with a lithium hydroxide carbon-dioxide absorbent for oxygen generation, a breathing bag and tubing to conduct breathing to and from the man. A plastic hood incorporating a mouth piece for communication provides also eye protection and prevents inhalation through the nose. Manned testing of a prototype system demonstrated the feasibility of this closed circuit no-maintenance breathing apparatus that provides for good voice communication.

  16. Operation and testing of Mark 10 Mod 3 underwater breathing apparatus

    NASA Technical Reports Server (NTRS)

    Milwee, W. I., Jr.

    1972-01-01

    Performance tests on a closed circuit, mixed gas underwater breathing apparatus are reported. The equipment is designed to provide a minimum diving duration of four hours at 1500 ft below sea surface; it senses oxygen partial pressure in the breathing gas mix and controls oxygen content of the breathing gas within narrow limits about a preset value. The breathing circuit subsystem provides respirable gas to the diver and removes carbon dioxide and moisture from the expired gas. Test results indicate undesirable variations in oxygen partial pressure with oxygen addition and insufficient carbon dioxide absorption.

  17. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  18. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  19. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  20. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  1. 42 CFR 84.81 - Compressed breathing gas and liquefied breathing gas containers; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.81 Compressed breathing... the container. (d) Compressed breathing gas contained valves or a separate charging system or adapter...

  2. 46 CFR 77.30-10 - Stowage.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...

  3. 46 CFR 77.30-10 - Stowage.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...

  4. 46 CFR 77.30-10 - Stowage.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...

  5. 46 CFR 77.30-10 - Stowage.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...

  6. 46 CFR 77.30-10 - Stowage.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...-contained breathing apparatus Self-contained breathing apparatus for refrigeration 1 Flame safety lamps... 100 2 1 1 1 Required only on vessels equipped with any refrigeration unit using ammonia to refrigerate any space with a volume of more than 20 cubic feet or with any refrigeration unit using fluorocarbons...

  7. 42 CFR 84.87 - Compressed gas filters; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Compressed gas filters; minimum requirements. 84.87...-Contained Breathing Apparatus § 84.87 Compressed gas filters; minimum requirements. All self-contained breathing apparatus using compressed gas shall have a filter downstream of the gas source to effectively...

  8. 42 CFR 84.87 - Compressed gas filters; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Compressed gas filters; minimum requirements. 84.87...-Contained Breathing Apparatus § 84.87 Compressed gas filters; minimum requirements. All self-contained breathing apparatus using compressed gas shall have a filter downstream of the gas source to effectively...

  9. 42 CFR 84.87 - Compressed gas filters; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Compressed gas filters; minimum requirements. 84.87...-Contained Breathing Apparatus § 84.87 Compressed gas filters; minimum requirements. All self-contained breathing apparatus using compressed gas shall have a filter downstream of the gas source to effectively...

  10. 42 CFR 84.87 - Compressed gas filters; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Compressed gas filters; minimum requirements. 84.87...-Contained Breathing Apparatus § 84.87 Compressed gas filters; minimum requirements. All self-contained breathing apparatus using compressed gas shall have a filter downstream of the gas source to effectively...

  11. 42 CFR 84.87 - Compressed gas filters; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Compressed gas filters; minimum requirements. 84.87...-Contained Breathing Apparatus § 84.87 Compressed gas filters; minimum requirements. All self-contained breathing apparatus using compressed gas shall have a filter downstream of the gas source to effectively...

  12. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Self-contained breathing apparatus; required components. 84.71 Section 84.71 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  13. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Self-contained breathing apparatus; required components. 84.71 Section 84.71 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  14. 42 CFR 84.71 - Self-contained breathing apparatus; required components.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Self-contained breathing apparatus; required components. 84.71 Section 84.71 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self...

  15. Post-dive ultrasound detection of gas in the liver of rats and scuba divers.

    PubMed

    L'abbate, Antonio; Marabotti, Claudio; Kusmic, Claudia; Pagliazzo, Antonino; Navari, Alessandro; Positano, Vincenzo; Palermo, Mario; Benassi, Antonio; Bedini, Remo

    2011-09-01

    In a previous study, we obtained histologic documentation of liver gas embolism in the rat model of rapid decompression. The aim of the study was to assess in the same model occurrence and time course of liver embolism using 2-D ultrasound imaging, and to explore by this means putative liver gas embolism in recreational scuba divers. Following 42 min compression at 7 ATA breathing air and 12 min decompression, eight surviving female rats were anesthetized and the liver imaged by ultrasound at 20 min intervals up to 120 min. A significant enhancement of echo signal was recorded from 60 to 120 min as compared to earlier post-decompression times. Enzymatic markers of liver damage (AST, ALT, and GGT) increased significantly at 24 h upon decompression. Twelve healthy experienced divers were studied basally and at 15-min intervals up to 60 min following a 30-min scuba dive at 30 msw depth. At 30 min upon surfacing echo images showed significant signal enhancement that progressed and reached plateau at 45 and 60 min. Total bilirubin at 24 h increased significantly (p = 0.02) with respect to basal values although within the reference range. In conclusion, 2-D ultrasound liver imaging allowed detection of gas embolism in the rat and defined the time course of gas accumulation. Its application to scuba divers revealed liver gas accumulation in all subjects in the absence of clear-cut evidence of liver damage or of any symptom. The clinical significance of our findings remains to be investigated.

  16. Goodenough Spring, Texas, USA: Discharge and water chemistry of a large spring deeply submerged under the binational Amistad Reservoir

    NASA Astrophysics Data System (ADS)

    Kamps, Ray H.; Tatum, Gregg S.; Gault, Mike; Groeger, Alan W.

    2009-06-01

    Goodenough Spring (Texas, USA) is a large spring near the border of the American state of Texas and the Mexican state of Coahuila, discharging into the international Amistad Reservoir on the river Rio Grande (Rio Bravo). Discharge was routinely measured from 1928 until 1968 to partition the flow of the river between the two countries in accordance with water-use treaties. Samples were analyzed for water-quality parameters in 1967-1968 prior to inundation under 45 m of Amistad Reservoir in 1968. Subsequently, discharge has been estimated indirectly by the International Boundary and Water Commission (IBWC). For the first direct measurements of the spring in 37 years, velocity and cross-sectional measurements were made and water samples collected in the summer of 2005 using advanced self-contained underwater breathing apparatus (SCUBA) techniques. Spring discharge was calculated at 2.03 m3 s-1, approximately one-half of the historical mean of 3.94 m3 s-1. In situ and laboratory analyses of samples for temperature, pH, dissolved oxygen, specific conductance, alkalinity, nitrate-nitrogen, dissolved solids, chloride, sulfate, fluoride, phosphorus, calcium, sodium, potassium, magnesium, and iron showed the water quality to be very good for human consumption and crop irrigation. Measurement values are relatively unchanged from those reported 37 years prior.

  17. Status of Research in Underwater Physiology

    DTIC Science & Technology

    1956-03-01

    Qc ýLEVELSý A 0 ~STAT US O F RESEARCH IN ~ UNDERWATER PHYSIOLOGY MARCH 1958I 0 79 0 .15 U This doc-iment was prapartd Ly the Physiology Grouo of the...under- water breathing patterns, are vitally necessary to determine whether or not rad- ical deviations from the present design of self-contained...certain SCUBA operations. In single mul- tilevel dives no known tables could apply without a rigid control of the depth-time factors, and even under

  18. Effects of Extremity Armor on Metabolic Cost and Gait Biomechanics

    DTIC Science & Technology

    2010-05-26

    of prosthetics , orthotics, and exercise equipment could benefit from knowing the tipping point at which a mass on the limb begins to effect metabolic...measured. For this, you wear a nose clip and 4 breathe through a rubber mouthpiece and valve , similar to those found in scuba diving 5 equipment. The...32 33 Stress fractures , or breaks of bones in the foot and leg, have been associated with road 34 marching while carrying loads, especially

  19. Enriched Air Nitrox Breathing Reduces Venous Gas Bubbles after Simulated SCUBA Diving: A Double-Blind Cross-Over Randomized Trial.

    PubMed

    Souday, Vincent; Koning, Nick J; Perez, Bruno; Grelon, Fabien; Mercat, Alain; Boer, Christa; Seegers, Valérie; Radermacher, Peter; Asfar, Pierre

    2016-01-01

    To test the hypothesis whether enriched air nitrox (EAN) breathing during simulated diving reduces decompression stress when compared to compressed air breathing as assessed by intravascular bubble formation after decompression. Human volunteers underwent a first simulated dive breathing compressed air to include subjects prone to post-decompression venous gas bubbling. Twelve subjects prone to bubbling underwent a double-blind, randomized, cross-over trial including one simulated dive breathing compressed air, and one dive breathing EAN (36% O2) in a hyperbaric chamber, with identical diving profiles (28 msw for 55 minutes). Intravascular bubble formation was assessed after decompression using pulmonary artery pulsed Doppler. Twelve subjects showing high bubble production were included for the cross-over trial, and all completed the experimental protocol. In the randomized protocol, EAN significantly reduced the bubble score at all time points (cumulative bubble scores: 1 [0-3.5] vs. 8 [4.5-10]; P < 0.001). Three decompression incidents, all presenting as cutaneous itching, occurred in the air versus zero in the EAN group (P = 0.217). Weak correlations were observed between bubble scores and age or body mass index, respectively. EAN breathing markedly reduces venous gas bubble emboli after decompression in volunteers selected for susceptibility for intravascular bubble formation. When using similar diving profiles and avoiding oxygen toxicity limits, EAN increases safety of diving as compared to compressed air breathing. ISRCTN 31681480.

  20. DECOMPRESSION FROM He-N2-O2 (TRIMIX) BOUNCE DIVES IS NOT MORE EFFICIENT THAN FROM He-O2 (HELIOX) BOUNCE DIVES

    DTIC Science & Technology

    2015-05-28

    true, trimix would be an attractive alternative to heliox for U. S. Navy MK 16 MOD 1 underwater breathing apparatus (UBA) diving. However, there is no...for the semi-closed circuit Canadian Underwater Mine-countermeasures Apparatus (CUMA) that are shorter than...diving15-17 and by the U.S. Navy for the MK 6 semi- closed circuit underwater breathing apparatus (UBA);18,19 each of these programs tested trimix schedules

  1. Physiological Event Prediction in Evaluations of Underwater Breathing Apparatus

    DTIC Science & Technology

    2016-10-25

    Navy Experimental Diving Unit TA 15-02 321 Bullfinch Rd. NEDU TR 16-04 Panama City, FL 32407-7015 October 2016 Physiological...Event Prediction in Evaluations of Underwater Breathing Apparatus NAVY EXPERIMENTAL DIVING UNIT Author...5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) 8. PERFORMING ORGANIZATION REPORT NUMBER Navy Experimental

  2. Composite Material Hazard Assessment at Crash Sites

    DTIC Science & Technology

    2015-01-01

    advanced composite materials. All personnel involved in rescue in close crash-site proximity are required to wear self -contained breathing apparatus...close crash-site proximity are required to wear self -contained breathing apparatus, chemical protective clothing, leather gloves, and neoprene...Take extra precaution when handling these materials. Nitrile rubber gloves can be worn underneath the leather gloves to provide chemical hazard

  3. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full... which shall not reduce the respiratory protective qualities of the apparatus. (c) Apparatus with...

  4. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full... which shall not reduce the respiratory protective qualities of the apparatus. (c) Apparatus with...

  5. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full... which shall not reduce the respiratory protective qualities of the apparatus. (c) Apparatus with...

  6. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full... which shall not reduce the respiratory protective qualities of the apparatus. (c) Apparatus with...

  7. 42 CFR 84.75 - Half-mask facepieces, full facepieces, mouthpieces; fit; minimum requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.75 Half-mask facepieces, full... which shall not reduce the respiratory protective qualities of the apparatus. (c) Apparatus with...

  8. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200 liters...

  9. 42 CFR 84.93 - Gas flow test; open-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; open-circuit apparatus. 84.93...-Contained Breathing Apparatus § 84.93 Gas flow test; open-circuit apparatus. (a) A static-flow test will be performed on all open-circuit apparatus. (b) The flow from the apparatus shall be greater than 200 liters...

  10. A metabolic simulator for unmanned testing of breathing apparatuses in hyperbaric conditions.

    PubMed

    Frånberg, Oskar; Loncar, Mario; Larsson, Åke; Ornhagen, Hans; Gennser, Mikael

    2014-11-01

    A major part of testing of rebreather apparatuses for underwater diving focuses on the oxygen dosage system. A metabolic simulator for testing breathing apparatuses was built and evaluated. Oxygen consumption was achieved through catalytic combustion of propene. With an admixture of carbon dioxide in the propene fuel, the system allowed the respiratory exchange ratio to be set freely within human variability and also made it possible to increase test pressures above the condensation pressure of propene. The system was tested by breathing ambient air in a pressure chamber with oxygen uptake (Vo₂) ranging from 1-4 L · min(-1), tidal volume (VT) from 1-3 L, breathing frequency (f) of 20 and 25 breaths/min, and chamber pressures from 100 to 670 kPa. The measured end-tidal oxygen concentration (Fo₂) was compared to calculated end-tidal Fo₂. The largest average difference in end-tidal Fo₂during atmospheric pressure conditions was 0.63%-points with a 0.28%-point average difference during the whole test. During hyperbaric conditions with pressures ranging from 100 to 670 kPa, the largest average difference in Fo₂was 1.68%-points seen during compression from 100 kPa to 400 kPa and the average difference in Fo₂during the whole test was 0.29%-points. In combination with a breathing simulator simulating tidal breathing, the system can be used for dynamic continuous testing of breathing equipment with changes in VT, f, Vo2, and pressure.

  11. 21 CFR 868.5165 - Nitric oxide administration apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nitric oxide administration apparatus. 868.5165... apparatus. (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be...

  12. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied... rated service time of the apparatus. (b) Where constant flow is used in conjunction with demand flow...

  13. 21 CFR 868.5165 - Nitric oxide administration apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nitric oxide administration apparatus. 868.5165... apparatus. (a) Identification. The nitric oxide administration apparatus is a device used to add nitric oxide to gases that are to be breathed by a patient. The nitric oxide administration apparatus is to be...

  14. 42 CFR 84.94 - Gas flow test; closed-circuit apparatus.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Gas flow test; closed-circuit apparatus. 84.94...-Contained Breathing Apparatus § 84.94 Gas flow test; closed-circuit apparatus. (a) Where oxygen is supplied... rated service time of the apparatus. (b) Where constant flow is used in conjunction with demand flow...

  15. Experimental and modeling study of thermal exposure of a self-contained breathing apparatus (SCBA).

    PubMed

    Donnelly, Michelle K; Yang, Jiann C

    2015-08-01

    An experimental apparatus designed to study firefighter safety equipment exposed to a thermal environment was developed. The apparatus consisted of an elevated temperature flow loop with the ability to heat the air stream up to 200°C. The thermal and flow conditions at the test section were characterized using thermocouples and bi-directional probes. The safety equipment examined in this study was a self-contained breathing apparatus (SCBA), including a facepiece and an air cylinder. The SCBA facepiece was placed on a mannequin headform and coupled to a breathing simulator that was programmed with a prescribed breathing pattern. The entire SCBA assembly was placed in the test section of the flow loop for these thermal exposure experiments. Three air stream temperatures, 100°C, 150°C, and 200°C, were used with the average air speed at the test section set at 1.4m/s and thermal exposure durations up to 1200 s. Measurements were made using type-K bare-bead thermocouples located in the mannequin's mouth and on the outer surface of the SCBA cylinder. The experimental results indicated that increasing the thermal exposure severity and duration increased the breathing air temperatures supplied by the SCBA. Temperatures of breathing air from the SCBA cylinder in excess of 60°C were observed over the course of the thermal exposure conditions used in most of the experiments. A mathematical model for transient heat transfer was developed to complement the thermal exposure experimental study. The model took into consideration forced convective heat transfer, quasi-steady heat conduction through the composite layers of the SCBA cylinder wall, the breathing pattern and action of the breathing simulator, and predicted air temperatures from the thermally exposed SCBA cylinder and temperatures at the outer surface of the SCBA cylinder. Model predictions agreed reasonably well with the experimental measurements. Published by Elsevier Ltd.

  16. NASA firefighters breathing system program report

    NASA Technical Reports Server (NTRS)

    Wood, W. B.

    1977-01-01

    Because of the rising incidence of respiratory injury to firefighters, local governments expressed the need for improved breathing apparatus. A review of the NASA firefighters breathing system program, including concept definition, design, development, regulatory agency approval, in-house testing, and program conclusion is presented.

  17. Cohort Study of Multiple Brain Lesions in Sport Divers: Role of a Patent Foramen Ovale

    NASA Technical Reports Server (NTRS)

    Knauth, Michael; Ries, Stefan; Pohimann, Stefan; Kerby, Tina; Forstring, Michael; Daffertshofer, Michael; Hennerici,Michael; Sartor, Klaus

    1997-01-01

    To investigate the role of a patent foramen ovale in the pathogenesis of multiple brain lesions acquired by sport divers in the absence of reported decompression symptoms. Design: Prospective double blind cohort study. . Setting Diving clubs around Heidelberg and departments of neuroradiology and neurology. Subjects: 87 sport divers with a minimum of 160 scuba dives (dives with self contained underwater breathing apparatus). Main outcome measures: Presence of multiple brain lesions visualised by cranial magnetic resonance imaging and presence and size of patent foramen ovale as documented by echocontrast transcranial Doppler ultrasonograhy. Results: 25 subjects were found to have a right-to-left shunt, 13 with a patent foramen ovale of high haemodynamic relevance. A total of 41 brain lesions were detected in 11 divers. There were seven brain lesions in seven divers without a right-to-left shunt and 34 lesions in four divers with a right-to-left shunt Multiple brain lesions occurred exclusively in three divers with a large patent foramen ovale (P=0.004). Conclusions: Multiple brain lesions in sport divers were associated with presence of a large patent foramen ovale. This association suggests paradoxical gas embolism as the pathological mechanism. A patent foramen ovale of high haemodynamic relevance seems to be an important risk factor for developing multiple brain lesions in sport divers.

  18. 42 CFR 84.88 - Breathing bag test.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Apparatus § 84.88 Breathing bag test. (a) Breathing bags will be tested in an air atmosphere saturated with... Institute upon request. (d) The air within the bag(s) shall not contain more than 100 parts per million of... 42 Public Health 1 2014-10-01 2014-10-01 false Breathing bag test. 84.88 Section 84.88 Public...

  19. 42 CFR 84.97 - Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... closed-circuit apparatus; maximum allowable limits. 84.97 Section 84.97 Public Health PUBLIC HEALTH... ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.97 Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable limits. (a) Open...

  20. 42 CFR 84.97 - Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... closed-circuit apparatus; maximum allowable limits. 84.97 Section 84.97 Public Health PUBLIC HEALTH... ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.97 Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable limits. (a) Open...

  1. KENNEDY SPACE CENTER, FLA. - Workers, covered in protective clothing and breathing apparatus, continue sandblasting on the Mobile Launcher Platform on Launch Pad 39A to remove corrosion before repainting. Routine maintenance includes sandblasting and repainting as preventive means to minimize corrosion.

    NASA Image and Video Library

    2003-09-12

    KENNEDY SPACE CENTER, FLA. - Workers, covered in protective clothing and breathing apparatus, continue sandblasting on the Mobile Launcher Platform on Launch Pad 39A to remove corrosion before repainting. Routine maintenance includes sandblasting and repainting as preventive means to minimize corrosion.

  2. 46 CFR 197.450 - Breathing gas tests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... taken at the connection point to the distribution system— (1) Every 6 months; and (2) After every repair or modification. (b) Purchased supplies of breathing mixtures supplied to a diver are checked before... commencement of diving operations, at the umbilical or underwater breathing apparatus connection point for the...

  3. Effect of oxygen-breathing during a decompression-stop on bubble-induced platelet activation after an open-sea air dive: oxygen-stop decompression.

    PubMed

    Pontier, J-M; Lambrechts, K

    2014-06-01

    We highlighted a relationship between decompression-induced bubble formation and platelet micro-particle (PMP) release after a scuba air-dive. It is known that decompression protocol using oxygen-stop accelerates the washout of nitrogen loaded in tissues. The aim was to study the effect of oxygen deco-stop on bubble formation and cell-derived MP release. Healthy experienced divers performed two scuba-air dives to 30 msw for 30 min, one with an air deco-stop and a second with 100% oxygen deco-stop at 3 msw for 9 min. Bubble grades were monitored with ultrasound and converted to the Kisman integrated severity score (KISS). Blood samples for cell-derived micro-particle analysis (AnnexinV for PMP and CD31 for endothelial MP) were taken 1 h before and after each dive. Mean KISS bubble score was significantly lower after the dive with oxygen-decompression stop, compared to the dive with air-decompression stop (4.3 ± 7.3 vs. 32.7 ± 19.9, p < 0.001). After the dive with an air-breathing decompression stop, we observed an increase of the post-dive mean values of PMP (753 ± 245 vs. 381 ± 191 ng/μl, p = 0.003) but no significant change in the oxygen-stop decompression dive (329 ± 215 vs. 381 +/191 ng/μl, p = 0.2). For the post-dive mean values of endothelial MP, there was no significant difference between both the dives. The Oxygen breathing during decompression has a beneficial effect on bubble formation accelerating the washout of nitrogen loaded in tissues. Secondary oxygen-decompression stop could reduce bubble-induced platelet activation and the pro-coagulant activity of PMP release preventing the thrombotic event in the pathogenesis of decompression sickness.

  4. Breathing zone air sampler

    DOEpatents

    Tobin, John

    1989-01-01

    A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

  5. Portable breathing apparatus for coal mines

    NASA Technical Reports Server (NTRS)

    Vandolah, R. W.

    1972-01-01

    The state of the art in portable oxygen breathing equipment is reported. Considered are self-containing as well as chemically generating oxygen sources and their effectiveness and limitations in mine rescue operations.

  6. Effects of oxygen-enriched air on cognitive performance during SCUBA-diving - an open-water study.

    PubMed

    Brebeck, Anne-Kathrin; Deussen, Andreas; Schmitz-Peiffer, Henning; Range, Ursula; Balestra, Costantino; Cleveland, Sinclair; Schipke, Jochen D

    2017-01-01

    Backround: Nitrogen narcosis impairs cognitive function, a fact relevant during SCUBA-diving. Oxygen-enriched air (nitrox) became popular in recreational diving, while evidence of its advantages over air is limited. Compare effects of nitrox28 and air on two psychometric tests. In this prospective, double-blind, open-water study, 108 advanced divers (38 females) were randomized to an air or a nitrox-group for a 60-min dive to 24 m salt water. Breathing gas effects on cognitive performance were assessed during the dive using a short- and long-term memory test and a number connection test. Nitrox28 divers made fewer mistakes only on the long-term memory test (p = 0.038). Female divers remembered more items than male divers (p < 0.001). There were no significant differences in the number connection test between the groups. Likely owing to the comparatively low N 2 reduction and the conservative dive, beneficial nitrox28 effects to diver performance were moderate but could contribute to diving safety.

  7. Method and apparatus for non-invasive evaluation of diaphragmatic function

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Wait, Juliette L. (Inventor); Nahormek, Patricia A. (Inventor); Cantrell, John H. (Inventor); Hanna-Hawver, Pamela D. (Inventor)

    1995-01-01

    A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

  8. Method and apparatus for non-invasive evaluation of diaphragmatic function

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Wait, Juliette L. (Inventor); Nahormek, Patricia A. (Inventor); Cantrell, John H. (Inventor); Hanna-Hawver, Pamela D. (Inventor)

    1994-01-01

    A method for non-invasive evaluation of diaphragmatic function in humans measures the thickness of the diaphragm in real time with an ultrasonic device, and displays the variations of diaphragm thickness versus time. Formulae are given for calculating a quantitative value for the reserve fatigue capacity of a patient's diaphragm from data obtained by measuring the time limits for maintaining a constant breathing pattern on the display at two different pressure differentials in series with the patient's airways. An apparatus for displaying the diaphragm thickness in real time is also described. The method can be used both on healthy patients and on patients with so severe breathing dysfunctions that they require breathing support from respirators.

  9. Portable breathing system. [a breathing apparatus using a rebreathing system of heat exchangers for carbon dioxide removal

    NASA Technical Reports Server (NTRS)

    Lovell, J. S. (Inventor)

    1979-01-01

    A semiclosed-loop rebreathing system is discussed for use in a hostile environment. A packed bed regenerative heat exchanger providing two distinct temperature humidity zones of breathing gas with one zone providing cool, relatively dry air and the second zone providing hot, moist air is described.

  10. Suicidal nitrogen inhalation by use of scuba full-face diving mask.

    PubMed

    Straka, Lubomir; Novomesky, Frantisek; Gavel, Anton; Mlynar, Juraj; Hejna, Petr

    2013-09-01

    A 29-year-old man was found dead lying on the bed in a hotel room in a famous Slovak mountain resort. He had a full-face diving mask on his face, connected through a diving breath regulator to a valve of an industrial (nondiving) high-pressure tank containing pure 100% nitrogen. The breath regulator (open-circuit type) used allowed inhalation of nitrogen without addition of open air, and the full-face diving mask assured aspiration of the gas even during the time of unconsciousness. At autopsy, we found the typical signs of suffocation. Toxicological analysis revealed 94.7% content of nitrogen in alveolar air. Following the completion of the police investigation, the manner of death was classified as a suicide. Within the medico-legal literature, there has been only one similar case of suicidal nitrogen inhalation described. © 2013 American Academy of Forensic Sciences.

  11. [Analysis of breath hydrogen (H2) in diagnosis of gastrointestinal function: validation of a pocket breath H2 test analyzer].

    PubMed

    Braden, B; Braden, C P; Klutz, M; Lembcke, B

    1993-04-01

    Breath hydrogen (H2) analysis, as used in gastroenterologic function tests, requires a stationary analysis system equipped with a gaschromatograph or an electrochemical sensor cell. Now a portable breath H2-analyzer has been miniaturized to pocket size (104 mm x 62 mm x 29 mm). The application of this device in clinical practice has been assessed in comparison to the standard GMI-exhaled monitor. The pocket analyzer showed a linear response to standards with H2-concentrations ranging from 0-100 ppm (n = 7), which was not different from the GMI-apparatus. The correlation of both methods during clinical application (lactose tolerance tests, mouth-to-coecum transit time determined with lactulose) was excellent (Y = 1.08 X + 0.96; r = 0.959). Using the new device, both, analysis (3 s vs. 90 s) and the reset-time (43 s vs. 140 s) were shorter whereas calibration was more feasible with the GMI-apparatus. It is concluded, that the considerably cheaper pocket-sized breath H2-analyzer is as precise and sensitive as the GMI-exhaled monitor, and thus presents a valid alternative for H2-breath tests.

  12. Real time chemical exposure and risk monitor

    DOEpatents

    Thrall, Karla D.; Kenny, Donald V.; Endres, George W. R.; Sisk, Daniel R.

    1997-01-01

    The apparatus of the present invention is a combination of a breath interface and an external exposure dosimeter interface to a chemical analysis device, all controlled by an electronic processor for quantitatively analyzing chemical analysis data from both the breath interface and the external exposure dosimeter for determining internal tissue dose. The method of the present invention is a combination of steps of measuring an external dose, measuring breath content, then analyzing the external dose and breath content and determining internal tissue dose.

  13. Real time chemical exposure and risk monitor

    DOEpatents

    Thrall, K.D.; Kenny, D.V.; Endres, G.W.R.; Sisk, D.R.

    1997-07-08

    The apparatus of the present invention is a combination of a breath interface and an external exposure dosimeter interface to a chemical analysis device, all controlled by an electronic processor for quantitatively analyzing chemical analysis data from both the breath interface and the external exposure dosimeter for determining internal tissue dose. The method of the present invention is a combination of steps of measuring an external dose, measuring breath content, then analyzing the external dose and breath content and determining internal tissue dose. 7 figs.

  14. 46 CFR 153.336 - Special cargo pump or pumproom requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... Section 153.336 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and... low pressure breathing quality air supply system for use with the breathing apparatus in the pumproom...

  15. 46 CFR 153.336 - Special cargo pump or pumproom requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... Section 153.336 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and... low pressure breathing quality air supply system for use with the breathing apparatus in the pumproom...

  16. 46 CFR 153.336 - Special cargo pump or pumproom requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Section 153.336 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and... low pressure breathing quality air supply system for use with the breathing apparatus in the pumproom...

  17. 46 CFR 153.336 - Special cargo pump or pumproom requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Section 153.336 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and... low pressure breathing quality air supply system for use with the breathing apparatus in the pumproom...

  18. Exploratory breath analyses for assessing toxic dermal exposure of firefighters during suppression of structural burns

    EPA Science Inventory

    Firefighters wear fireproof clothing and self-contained breathing apparatus (SCBA) during rescue and fire suppression activities to protect against acute effects from heat and toxic chemicals. Fire services are also concerned about long-term health outcomes from chemical exposure...

  19. Firefighter's Breathing System

    NASA Technical Reports Server (NTRS)

    Mclaughlan, P. B.; Giorgini, E. A.; Sullivan, J. L.; Simmonds, M. R.; Beck, E. J.

    1976-01-01

    System, based on open-loop demand-type compressed air concept, is lighter and less bulky than former systems, yet still provides thirty minutes of air supply. Comfort, visibility, donning time, and breathing resistance have been improved. Apparatus is simple to recharge and maintain and is comparable in cost to previously available systems.

  20. Safety Priorities and Underestimations in Recreational Scuba Diving Operations: A European Study Supporting the Implementation of New Risk Management Programmes

    PubMed Central

    Lucrezi, Serena; Egi, Salih Murat; Pieri, Massimo; Burman, Francois; Ozyigit, Tamer; Cialoni, Danilo; Thomas, Guy; Marroni, Alessandro; Saayman, Melville

    2018-01-01

    Introduction: Scuba diving is an important marine tourism sector, but requires proper safety standards to reduce the risks and increase accessibility to its market. To achieve safety goals, safety awareness and positive safety attitudes in recreational scuba diving operations are essential. However, there is no published research exclusively focusing on scuba divers’ and dive centres’ perceptions toward safety. This study assessed safety perceptions in recreational scuba diving operations, with the aim to inform and enhance safety and risk management programmes within the scuba diving tourism industry. Materials and Methods: Two structured questionnaire surveys were prepared by the organisation Divers Alert Network and administered online to scuba diving operators in Italy and scuba divers in Europe, using a mixture of convenience and snowball sampling. Questions in the survey included experience and safety offered at the dive centre; the buddy system; equipment and accessories for safe diving activities; safety issues in the certification of new scuba divers; incidents/accidents; and attitudes toward safety. Results: 91 scuba diving centres and 3,766 scuba divers participated in the study. Scuba divers gave importance to safety and the responsiveness of service providers, here represented by the dive centres. However, they underestimated the importance of a personal emergency action/assistance plan and, partly, of the buddy system alongside other safety procedures. Scuba divers agreed that some risks, such as those associated with running out of gas, deserve attention. Dive centres gave importance to aspects such as training and emergency action/assistance plans. However, they were limitedly involved in safety campaigning. Dive centres’ perceptions of safety in part aligned with those of scuba divers, with some exceptions. Conclusion: Greater responsibility is required in raising awareness and educating scuba divers, through participation in prevention campaigns and training. The study supports the introduction of programmes aiming to create a culture of safety among dive centres and scuba divers. Two examples, which are described in this paper, include the Hazard Identification and Risk Assessment protocol for dive centres and scuba divers, and the Diving Safety Officer programme to create awareness, improve risk management, and mitigate health and safety risks. PMID:29628904

  1. Safety Priorities and Underestimations in Recreational Scuba Diving Operations: A European Study Supporting the Implementation of New Risk Management Programmes.

    PubMed

    Lucrezi, Serena; Egi, Salih Murat; Pieri, Massimo; Burman, Francois; Ozyigit, Tamer; Cialoni, Danilo; Thomas, Guy; Marroni, Alessandro; Saayman, Melville

    2018-01-01

    Introduction: Scuba diving is an important marine tourism sector, but requires proper safety standards to reduce the risks and increase accessibility to its market. To achieve safety goals, safety awareness and positive safety attitudes in recreational scuba diving operations are essential. However, there is no published research exclusively focusing on scuba divers' and dive centres' perceptions toward safety. This study assessed safety perceptions in recreational scuba diving operations, with the aim to inform and enhance safety and risk management programmes within the scuba diving tourism industry. Materials and Methods: Two structured questionnaire surveys were prepared by the organisation Divers Alert Network and administered online to scuba diving operators in Italy and scuba divers in Europe, using a mixture of convenience and snowball sampling. Questions in the survey included experience and safety offered at the dive centre; the buddy system; equipment and accessories for safe diving activities; safety issues in the certification of new scuba divers; incidents/accidents; and attitudes toward safety. Results: 91 scuba diving centres and 3,766 scuba divers participated in the study. Scuba divers gave importance to safety and the responsiveness of service providers, here represented by the dive centres. However, they underestimated the importance of a personal emergency action/assistance plan and, partly, of the buddy system alongside other safety procedures. Scuba divers agreed that some risks, such as those associated with running out of gas, deserve attention. Dive centres gave importance to aspects such as training and emergency action/assistance plans. However, they were limitedly involved in safety campaigning. Dive centres' perceptions of safety in part aligned with those of scuba divers, with some exceptions. Conclusion: Greater responsibility is required in raising awareness and educating scuba divers, through participation in prevention campaigns and training. The study supports the introduction of programmes aiming to create a culture of safety among dive centres and scuba divers. Two examples, which are described in this paper, include the Hazard Identification and Risk Assessment protocol for dive centres and scuba divers, and the Diving Safety Officer programme to create awareness, improve risk management, and mitigate health and safety risks.

  2. Portable Breathing Assembly

    NASA Image and Video Library

    2017-06-12

    In the Space Station Processing Facility at NASA's Kennedy Space Center in Florida, Jacobs Test and Operations Support Contract, or TOSC, technicians fill portable breathing apparatuses, or PBAS. The PBAs are to be use on board the International Space Staton to provide astronauts with breathable air in the event of a fire or other emergency situation.

  3. Tolerance to external breathing resistance with particular reference to high inspiratory resistance

    NASA Technical Reports Server (NTRS)

    Bentley, R. A.; Griffin, O. G.; Love, R. G.; Muir, D. C. F.; Sweetland, K. F.

    1972-01-01

    The ability of men to exercise while breathing through graded inspiratory resistances was studied in order to define acceptable respiratory mouthpiece assembly standards. Experimental results with subjects wearing breathing masks and walking for 30 min on treadmills were used to calculate expiratory work rates. It is concluded that the airflow must be appropriate to the upper limit of minute ventilation likely to be encountered in the men wearing the apparatus.

  4. Performance of life support breathing apparatus for under-ice diving operations.

    PubMed

    Lang, Michael A; Clarke, John R

    2017-01-01

    Single-hose scuba regulators dived in very cold water may suffer first- or second-stage malfunction, yielding complete occlusion of air flow or massive freeflow that rapidly expends a diver's air supply. This study, conducted in Antarctica, evaluated the under-ice performance of a sampling of commercially available regulators. Seventeen science divers logged a total of 305 dives in -1.86°C seawater under 6-meter-thick Antarctic fast-ice over two field seasons in 2008 and 2009. Dive profiles had an average depth of 30 msw and dive time of 29 minutes, including a mandatory three-minute safety stop at 6 msw. Sixty-nine unmodified regulator units (17 models) from 12 different manufacturers underwent standardized pre-dive regulator care and were randomly assigned to divers. Depths and times of onset of second-stage regulator freeflow were recorded. In 305 dives, there were 65 freeflows. The freeflows were not evenly distributed across the regulator brands. Regulator failure rates fell into two categories (⟨ 11% and ⟩ 26%). The regulators classified for the purpose of the test as "acceptable" (⟨ 11% failure rate: Dive-Rite Jetstream, Sherwood Maximus SRB3600, Poseidon Xstream Deep, Poseidon Jetstream, Sherwood Maximus SRB7600, Poseidon Cyklon, Mares USN22 Abyss) experienced only nine freeflows out of 146 exposures for a 6% overall freeflow incidence. Those classified as "unacceptable" (⟨ 26% failure rate) suffered 56 freeflows out of 159 exposures (35% freeflow incidence.). Contrary to expectations, the pooled incidences for the seven best performing regulators was significantly different by Chi-square test from the 10 remaining regulators (P ⟨ 0.001).

  5. Benefit from NASA

    NASA Image and Video Library

    2001-10-01

    Technology used to provide thermal protection for Apollo astronauts and spacecraft components provides firefighters with better protective clothing and equipment. Spinoffs include a portable firefighting module, protective clothing for workers in hazardous environments, fire-retardant paints and forms, fireblocking coating for outdoor structures, and flame-resistant fabric. Perhaps the farthest reaching is the breathing apparatus worn by firefighters throughout the U.S. for protection against smoke inhalation injury. The breathing system weighs approximately 20 pounds, one-third less than past systems, and it enables the wearer to have improved mobility. It consists of a face mask, frame and harness, a warning device, and an air bottle. The basic air cylinder offers the same 30-minutes of operation time as its predecessor. The result is a drastic reduction in the number of inhalation injuries to firefighters. Though they have made many design modifications and refinements, manufacturers of breathing apparatus still incorporate the original NASA technology.

  6. 42 CFR 84.99 - Man tests; testing conditions; general requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...

  7. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  8. 42 CFR 84.99 - Man tests; testing conditions; general requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...

  9. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  10. 42 CFR 84.99 - Man tests; testing conditions; general requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...

  11. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests; performance requirements. 84.103 Section...-Contained Breathing Apparatus § 84.103 Man tests; performance requirements. (a) The apparatus shall satisfy... is 24 ±6 °C. (75 ±10 °F.), the maximum temperature of inspired air recorded during man tests shall...

  12. 42 CFR 84.99 - Man tests; testing conditions; general requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests; testing conditions; general requirements...-Contained Breathing Apparatus § 84.99 Man tests; testing conditions; general requirements. (a) The man tests...) All man tests will be conducted by the Institute. (d) The apparatus will be examined before each man...

  13. 42 CFR 84.98 - Tests during low temperature operation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Tests during low temperature operation. 84.98...-Contained Breathing Apparatus § 84.98 Tests during low temperature operation. (a) The applicant shall... apparatus will be worn in the low temperature chamber for 30 minutes, or for the service time of the...

  14. 42 CFR 84.98 - Tests during low temperature operation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Tests during low temperature operation. 84.98...-Contained Breathing Apparatus § 84.98 Tests during low temperature operation. (a) The applicant shall... apparatus will be worn in the low temperature chamber for 30 minutes, or for the service time of the...

  15. 42 CFR 84.98 - Tests during low temperature operation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Tests during low temperature operation. 84.98...-Contained Breathing Apparatus § 84.98 Tests during low temperature operation. (a) The applicant shall... apparatus will be worn in the low temperature chamber for 30 minutes, or for the service time of the...

  16. 42 CFR 84.98 - Tests during low temperature operation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Tests during low temperature operation. 84.98...-Contained Breathing Apparatus § 84.98 Tests during low temperature operation. (a) The applicant shall... apparatus will be worn in the low temperature chamber for 30 minutes, or for the service time of the...

  17. 42 CFR 84.98 - Tests during low temperature operation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Tests during low temperature operation. 84.98...-Contained Breathing Apparatus § 84.98 Tests during low temperature operation. (a) The applicant shall... apparatus will be worn in the low temperature chamber for 30 minutes, or for the service time of the...

  18. Metabolic analyzer. [for measuring metabolic rate and breathing dynamics of human beings

    NASA Technical Reports Server (NTRS)

    Rummel, J. A.; Perry, C. L. (Inventor)

    1974-01-01

    An apparatus is described for the measurement of metabolic rate and breathing dynamics in which inhaled and exhaled breath are sensed by sealed, piston-displacement type spirometers. These spirometers electrically measure the volume of inhaled and exhaled breath. A mass spectrometer analyzes simultaneously for oxygen, carbon dioxide, nitrogen and water vapor. Computation circuits are responsive to the outputs of the spirometers, mass spectrometer, temperature, pressure and timing signals and compute oxygen consumption, carbon dioxide production, minute volume and respiratory exchange ratio. A selective indicator provides for read-out of these data at predetermined cyclic intervals.

  19. Finding Environmental Knowledge in SCUBA-Based Textual Materials

    ERIC Educational Resources Information Center

    Gündogdu, Cemal; Aygün, Yalin; Ilkim, Mehmet

    2018-01-01

    As marine environments within the adventure domain are future key-settings for recreational SCUBA diving experience, SCUBA-based textual materials should provide insight into environmental knowledge that is well connected to the novice divers' behaviour and attitude. This research is concerned with a major recreational SCUBA diver manual for…

  20. The effect of firefighter protective garments, self-contained breathing apparatus and exertion in the heat on postural sway.

    PubMed

    White, Scott C; Hostler, David

    2017-08-01

    Fire suppression wearing thermal protective clothing (TPC) and self-contained breathing apparatus (SCBA) challenges a firefighter's balance and may explain firefighter falls. Postural control based on force plate centre of pressure (COP) was compared for healthy subjects wearing TPC and SCBA before and after 20 min of heavy physical exertion in hot conditions. Baseline measures with and without TPC and SCBA (two different SCBA cylinder masses) were compared before and after exertion that included elements of fire suppression activities in an environmental chamber. COP excursion and variability increased with exertion for TPC and SCBA conditions compared to non-stressed conditions. The two different cylinder masses had no significant effect. Wearing TPC and SCBA when physically stressed in a hot environment increases postural sway and exacerbates postural control. Subjects compensated for the extra mass and adjusted to control postural sway with the addition of TPC and SCBA, but the stress protocol amplified these adjustments. Practitioner Summary: Firefighters wear thermal protective clothing (TPC) and self-contained breathing apparatus (SCBA) when heat-stressed and fatigued. Wearing TPC and SCBA was found to negatively impact balance when stressed, but not for non-stressed or two different sized SCBA tanks. Simulating fire-ground conditions wearing TPC and SCBA should be considered for improving balance.

  1. Energetics of jellyfish locomotion determined from field measurements using a Self- Contained Underwater Velocimetry Apparatus (SCUVA)

    NASA Astrophysics Data System (ADS)

    Katija, K.; Dabiri, J. O.

    2007-12-01

    We conduct laboratory measurements of the flow fields induced by Aurelia labiata over a range of sizes using the method of digital particle image velocimetry (DPIV). The flow field measurements are used to directly quantify the kinetic energy induced by the swimming motions of individual medusae. This method provides details regarding the temporal evolution of the energetics during a swimming cycle and its scaling with bell diameter. These types of measurements also allow for the determination of propulsive efficiency, which can be used to compare various methods of propulsion, both biological and artificial. We then describe the development and application of a Self-Contained Underwater Velocimetry Apparatus (SCUVA), a device that enables a single SCUBA diver to make DPIV measurements of animal-fluid interactions in the field. Improvements and adjustments made to the original system will be presented, and a comparison between the animal-induced flow fields in the laboratory and in the field will be made.

  2. [Scuba diving in children: Physiology, risks and recommendations].

    PubMed

    Cilveti, R; Osona, B; Peña, J A; Moreno, L; Asensio, O

    2015-12-01

    The increase in recreational scuba diving in recent years, including children, involves risks and the possibility of accidents. While legislation, conditions and risks of scuba diving are well documented in adults, scientific evidence in scuba diving by children and adolescents is sparse and isolated. Furthermore, existing guidelines and recommendations for adults cannot be transferred directly to children. These circumstances have led to the Group on Techniques of the Spanish Society of Pediatric Pulmonology (SENP) to perform a literature search to review and update the knowledge about scuba diving in children. Physiological adaptations of the body are examined during the dive, as well as the anatomical and physiological characteristics of children that should be taken into account in scuba diving. The most common types of accidents and its causes, as well as the risks of scuba diving practice in children with previous diseases are discussed, along with details of the medical and psychological requirements for scuba diving to be considered in the assessment of child and adolescent. A list of recommendations for scuba diving with compressed air in children is presented by a group of experts. Copyright © 2015 Asociación Española de Pediatría. Published by Elsevier España, S.L.U. All rights reserved.

  3. Space Technology for the Fire Department

    NASA Technical Reports Server (NTRS)

    1986-01-01

    A National Bureau of Standards/NASA project directed by Johnson resulted in a lightweight breathing system including face mask, frame, harness and air bottle marketed by Scott Aviation. Aluminum composite material was used; frame and harness were easier to put on and take off. Today every major manufacturer of breathing apparatus incorporates NASA technology in some form, and inhalation injuries have been reduced.

  4. Normative tolerances for scuba divers and snorkelers: An application of the Potential for Conflict index2

    Treesearch

    Lauren M. Heesemann; Jerry J. Vaske; David K. Loomis

    2010-01-01

    This study examines Florida Keys snorkeler and SCUBA diver encounter norms using the Potential for Conflict Index2 (PCI2). Snorkelers and SCUBA divers evaluated the acceptability of encountering a specific number of other snorkelers and SCUBA divers on a 7-point scale ranging from extremely acceptable (3) to extremely...

  5. An upgraded SCUBA-2 for JCMT

    NASA Astrophysics Data System (ADS)

    Bintley, Dan; Dempsey, Jessica T.; Friberg, Per; Holland, Wayne S.; MacIntosh, Michael J.

    2016-07-01

    SCUBA-2 is a state of the art wide field camera on the JCMT. SCUBA-2 has been fully operational since November 2011, producing a wide range of science results, including a unique series of survey programs. A new large survey programme commenced in 2015, which included for the first time, polarisation sensitive measurements using POL-2, the polarimeter ancillary instrument. We discuss proposals and the science case for upgrading SCUBA-2 with new detector arrays that will keep SCUBA-2 and the JCMT at the forefront of continuum submillimetre science.

  6. Metabolic analyzer. [for Skylab mission

    NASA Technical Reports Server (NTRS)

    Perry, C. L.

    1973-01-01

    An apparatus is described for the measurement of metabolic rate and breathing dynamics in which inhaled and exhaled breath are sensed by sealed, piston-displacement type spirometers. These spirometers electrically measure the volume of inhaled and exhaled breath. A mass spectrometer analyzes simultaneously for oxygen, carbon dioxide, nitrogen, and water vapor. Circuits responsive to the outputs of the spirometers, mass spectrometer, temperature, pressure, and timing signals compute oxygen consumption, carbon dioxide production, minute volume, and respiratory exchange ratio. A selective indicator provides for readout of these data at predetermined cyclic intervals.

  7. 42 CFR 84.97 - Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... machine. An acceptable method for measuring the concentration of carbon dioxide is described in Bureau of Mines Report of Investigations 6865, A Machine-Test Method for Measuring Carbon Dioxide in the Inspired... of 10.5 liters. (3) A sedentary breathing machine cam will be used. (4) The apparatus will be tested...

  8. 42 CFR 84.97 - Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... machine. An acceptable method for measuring the concentration of carbon dioxide is described in Bureau of Mines Report of Investigations 6865, A Machine-Test Method for Measuring Carbon Dioxide in the Inspired... of 10.5 liters. (3) A sedentary breathing machine cam will be used. (4) The apparatus will be tested...

  9. 42 CFR 84.97 - Test for carbon dioxide in inspired gas; open- and closed-circuit apparatus; maximum allowable...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... machine. An acceptable method for measuring the concentration of carbon dioxide is described in Bureau of Mines Report of Investigations 6865, A Machine-Test Method for Measuring Carbon Dioxide in the Inspired... of 10.5 liters. (3) A sedentary breathing machine cam will be used. (4) The apparatus will be tested...

  10. SCUBA-2: The next generation wide-field imager for the James Clerk Maxwell Telescope

    NASA Astrophysics Data System (ADS)

    Holland, W. S.; Duncan, W. D.; Kelly, B. D.; Peacocke, T.; Robson, E. I.; Irwin, K. D.; Hilton, G.; Rinehart, S.; Ade, P. A. R.; Griffin, M. J.

    2000-12-01

    We describe SCUBA-2 - the next generation continuum imaging camera for the James Clerk Maxwell Telescope. The instrument will capitalise on the success of the current SCUBA camera, by having a much larger field-of- view and improved sensitivity. SCUBA-2 will be able to map the submillimetre sky several hundred times faster than SCUBA to the same noise level. Many areas of astronomy are expected to benefit - from large scale cosmological surveys to probe galaxy formation and evolution to studies of the earliest stages of star formation in our own Galaxy. Perhaps the most exciting prospect that SCUBA-2 will offer is in the statistical significance of wide-field surveys. The key science requirements of the new camera are the ability to make very deep images - reaching background confusion levels in only a couple of hours; to generate high fidelity images at two wavelengths simultaneously; to map large areas of sky (tens of degrees) to a reasonable depth in only a few hours; carry out photometry of known-position point-sources to a high accuracy. The technical design of SCUBA-2 will incorporate new technology transition-edge sensors as the detecting element, with signals being read out using multiplexed SQUID amplifiers. As in SCUBA there will be two arrays operating at 450 and 850 microns simultaneously. Fully-sampling a field-of-voew of 8 arcminutes square will require 25,600 and 6,400 pixels at 450 and 850 microns respectively (cf 91 and 37 pixels with SCUBA!). Each pixel will have diffraction-limited resolution on the sky and a sensitivity dominated by the background photon noise. SCUBA-2 is a collaboration between a number of institutions. We anticipate delivery of the final instrument to the telescope before the end of 2005.

  11. Depth refuge and the impacts of SCUBA spearfishing on coral reef fishes.

    PubMed

    Lindfield, Steven J; McIlwain, Jennifer L; Harvey, Euan S

    2014-01-01

    In recent decades, spearfishing with SCUBA has emerged as an efficient method for targeting reef fish in deeper waters. However, deeper waters are increasingly recognised as a potential source of refuge that may help sustain fishery resources. We used a combination of historical catch data over a 20-year time period and fishery-independent surveys to investigate the effects of SCUBA spearfishing on coral reef fish populations in the southern Mariana Islands. Two jurisdictions were studied; Guam, where SCUBA spearfishing is practiced, and the nearby Commonwealth of Northern Mariana Islands (CNMI), where SCUBA spearfishing has been banned since 2003. Fishery-independent data were collected using baited remote underwater stereo-video systems (stereo-BRUVs) stratified by depth, marine protected area status and jurisdiction. Herbivores (primary consumers) dominated spearfishing catches, with parrotfish (scarines) and surgeonfish/unicornfish (acanthurids) the main groups harvested. However, the large, endangered humphead wrasse (Cheilinus undulatus) was the main species by weight landed by SCUBA spearfishers. SCUBA spearfishing was associated with declining size of scarines over time and catches shifting from a dominance of large parrotfishes to a mixed assemblage with increasing proportions of acanthurids. Comparisons between Guam and the nearby CNMI revealed differences in the assemblage of fished species and also greater size of scarines and acanthurids in deep water where SCUBA fishing is banned. These results suggest that SCUBA spearfishing impacts reef fish populations and that the restriction of this fishing method will ensure refuge for fish populations in deeper waters. We recommend a ban on SCUBA spearfishing to preserve or aid the recovery of large, functionally important coral reef species and to improve the sustainability of coral reef fisheries.

  12. Depth Refuge and the Impacts of SCUBA Spearfishing on Coral Reef Fishes

    PubMed Central

    Lindfield, Steven J.; McIlwain, Jennifer L.; Harvey, Euan S.

    2014-01-01

    In recent decades, spearfishing with SCUBA has emerged as an efficient method for targeting reef fish in deeper waters. However, deeper waters are increasingly recognised as a potential source of refuge that may help sustain fishery resources. We used a combination of historical catch data over a 20-year time period and fishery-independent surveys to investigate the effects of SCUBA spearfishing on coral reef fish populations in the southern Mariana Islands. Two jurisdictions were studied; Guam, where SCUBA spearfishing is practiced, and the nearby Commonwealth of Northern Mariana Islands (CNMI), where SCUBA spearfishing has been banned since 2003. Fishery-independent data were collected using baited remote underwater stereo-video systems (stereo-BRUVs) stratified by depth, marine protected area status and jurisdiction. Herbivores (primary consumers) dominated spearfishing catches, with parrotfish (scarines) and surgeonfish/unicornfish (acanthurids) the main groups harvested. However, the large, endangered humphead wrasse (Cheilinus undulatus) was the main species by weight landed by SCUBA spearfishers. SCUBA spearfishing was associated with declining size of scarines over time and catches shifting from a dominance of large parrotfishes to a mixed assemblage with increasing proportions of acanthurids. Comparisons between Guam and the nearby CNMI revealed differences in the assemblage of fished species and also greater size of scarines and acanthurids in deep water where SCUBA fishing is banned. These results suggest that SCUBA spearfishing impacts reef fish populations and that the restriction of this fishing method will ensure refuge for fish populations in deeper waters. We recommend a ban on SCUBA spearfishing to preserve or aid the recovery of large, functionally important coral reef species and to improve the sustainability of coral reef fisheries. PMID:24663400

  13. High doses of pseudoephedrine hydrochloride accelerate onset of CNS oxygen toxicity seizures in unanesthetized rats.

    PubMed

    Pilla, R; Held, H E; Landon, C S; Dean, J B

    2013-08-29

    Pseudoephedrine (PSE) salts (hydrochloride and sulfate) are commonly used as nasal and paranasal decongestants by scuba divers. Anecdotal reports from the Divers Alert Network suggest that taking PSE prior to diving while breathing pure O₂ increases the risk for CNS oxygen toxicity (CNS-OT), which manifests as seizures. We hypothesized that high doses of PSE reduce the latency time to seizure (LS) in unanesthetized rats breathing 5 atmospheres absolute (ATA) of hyperbaric oxygen. Sixty-three male rats were implanted with radio-transmitters that recorded electroencephalogram activity and body temperature. After ≥7-day recovery, and 2 h before "diving", each rat was administered either saline solution (control) or PSE hydrochloride intragastrically at the following doses (mg PSE/kg): 0, 40, 80, 100, 120, 160, and 320. Rats breathed pure O₂ and were dived to 5ATA until the onset of behavioral seizures coincident with neurological seizures. LS was the time elapsed between reaching 5ATA and exhibiting seizures. We observed a significant dose-dependent decrease in the LS at doses of 100-320 mg/kg, whereas no significant differences in LS from control value were observed at doses ≤80 mg/kg. Our findings showed that high doses of PSE accelerate the onset of CNS-OT seizures in unanesthetized rats breathing 5ATA of poikilocapnic hyperoxia. Extrapolating our findings to humans, we conclude that the recommended daily dose of PSE should not be abused prior to diving with oxygen-enriched gas mixes or pure O₂. Copyright © 2013 IBRO. Published by Elsevier Ltd. All rights reserved.

  14. Chronic daily headache with analgesics overuse in professional women breath-hold divers.

    PubMed

    Choi, Jay Chol; Lee, Jung Seok; Kang, Sa-Yoon; Kang, Ji-Hoon; Bae, Jong-Myon

    2008-07-01

    The object of this study is to investigate the prevalence and characteristics of headache in Korean professional women breath-hold divers, including their overuse of analgesics. Headache is a common problem encountered in clinical practice, and undersea divers exhibit unique causes of headache in addition to other common primary headaches. Many scuba divers are known to use various types of drugs to overcome dive-related symptoms or to enhance their underwater performance. The target population of this study was women divers in the northern district of Jeju Island who were registered in the divers' union. Data were collected using telephone interviews with a structured questionnaire. Headache was diagnosed and classified according to criteria of the International Headache Society. Nine hundred and eleven (80.3%) divers responded to the telephone interview. The prevalence rates of headache were 21.4% for tension-type headache and 9.1% for migraine. One hundred and four divers (11.4%) fulfilled the criteria for chronic daily headache (CDH). Overuse of combination analgesics was reported by 70.7% of divers. Women divers with CDH were significantly older and they complained more of tinnitus and dizziness, and had a greater history of hypertension than divers without headache. The prevalence of CDH is high in Korean professional women breath-hold divers, with many of them being combination-analgesics overusers.

  15. A fractionation of the physiological burden of the personal protective equipment worn by firefighters.

    PubMed

    Taylor, Nigel A S; Lewis, Michael C; Notley, Sean R; Peoples, Gregory E

    2012-08-01

    Load carriage increases physiological strain, reduces work capacity and elevates the risk of work-related injury. In this project, the separate and combined physiological consequences of wearing the personal protective equipment used by firefighters were evaluated. The overall impact upon performance was first measured in 20 subjects during a maximal, job-related obstacle course trial and an incremental treadmill test to exhaustion (with and without protective equipment). The fractional contributions of the thermal protective clothing, helmet, breathing apparatus and boots were then separately determined during steady-state walking (4.8 km h(-1), 0% gradient) and bench stepping (20 cm at 40 steps min(-1)). The protective equipment reduced exercise tolerance by 56% on a treadmill, with the ambulatory oxygen consumption reserve (peak minus steady-state walking) being 31% lower. For the obstacle course, performance declined by 27%. Under steady-state conditions, the footwear exerted the greatest relative metabolic impact during walking and bench stepping, being 8.7 and 6.4 times greater per unit mass than the breathing apparatus. Indeed, the relative influence of the clothing on oxygen cost was at least three times that of the breathing apparatus. Therefore, the most efficient way to reduce the physiological burden of firefighters' protective equipment, and thereby increase safety, would be to reduce the mass of the boots and thermal protective clothing.

  16. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self..., including all completely assembled, portable, self-contained devices designed for use as respiratory...

  17. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self..., including all completely assembled, portable, self-contained devices designed for use as respiratory...

  18. 42 CFR 84.70 - Self-contained breathing apparatus; description.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self..., including all completely assembled, portable, self-contained devices designed for use as respiratory...

  19. Submaximal exercise with self-contained breathing apparatus: the effects of hyperoxia and inspired gas density.

    PubMed

    Eves, Neil D; Petersen, Stewart R; Jones, Richard L

    2003-10-01

    The self-contained breathing apparatus (SCBA) used by firefighters, and other working in dangerous environments, adds an external resistance to expiration, which increases expiratory work during heavy exercise. Compressed air is typically used with the SCBA and we hypothesized that changing the inspired oxygen concentration and/or gas density with helium would reduce the external expiratory resistance. On separate days, 15 men completed four 30-min bouts of treadmill exercise dressed in protective clothing and breathing the test gases through the SCBA. Four different gas mixtures were assigned in random order: [compressed air (NOX: 21% O2, 79% N2), hyperoxia (HOX: 40% O2, 60% N2), normoxic-helium (HE-OX: 21% O2, 79% He), and helium-hyperoxia (HE-HOX: 40% O2, 60% He)]. Compared with NOX, the two helium mixtures (but not HOX), decreased the external breathing resistance and all three gas mixtures decreased the peak expired mask pressure and the ventilatory mass moved. Both hyperoxic mixtures decreased blood lactate and the rating of perceived exertion was decreased at 30 min with HE-HOX. These results demonstrate that the helium-based gas mixtures, and to a lesser extent HOX, reduce the expiratory work associated with the SCBA during strenuous exercise.

  20. The SCUBA-2 SRO data reduction cookbook

    NASA Astrophysics Data System (ADS)

    Chapin, Edward; Dempsey, Jessica; Jenness, Tim; Scott, Douglas; Thomas, Holly; Tilanus, Remo P. J.

    This cookbook provides a short introduction to starlink\\ facilities, especially smurf, the Sub-Millimetre User Reduction Facility, for reducing and displaying SCUBA-2 SRO data. We describe some of the data artefacts present in SCUBA-2 time series and methods we employ to mitigate them. In particular, we illustrate the various steps required to reduce the data, and the Dynamic Iterative Map-Maker, which carries out all of these steps using a single command. For information on SCUBA-2 data reduction since SRO, please SC/21.

  1. 46 CFR 153.527 - Toxic vapor protection.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... emergency escape breathing apparatus does not protect the eyes from vapors, a set of goggles that either: (1) Meet the specifications of ANSI Practice for Occupational and Educational Eye and Face Protection, Z-87...

  2. 46 CFR 153.527 - Toxic vapor protection.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... emergency escape breathing apparatus does not protect the eyes from vapors, a set of goggles that either: (1) Meet the specifications of ANSI Practice for Occupational and Educational Eye and Face Protection, Z-87...

  3. 30 CFR 49.6 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... TRAINING MINE RESCUE TEAMS § 49.6 Equipment and maintenance requirements. (a) Each mine rescue station..., applicable to the supplied breathing apparatus and sufficient to sustain each team for eight hours while...

  4. 30 CFR 49.6 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... TRAINING MINE RESCUE TEAMS § 49.6 Equipment and maintenance requirements. (a) Each mine rescue station..., applicable to the supplied breathing apparatus and sufficient to sustain each team for eight hours while...

  5. Improved self-contained breathing apparatus concept. Final report Oct 80-Jun 82

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, L.; Walker, J.

    1982-08-01

    Past operational experiences of USAF fire fighting and rescue teams have indicated the need for an improved self-contained breathing apparatus (SCBA). In October 1980, a contract was awarded to Electronic Data Systems, Panama City, Florida, to design and develop a prototype SCBA that would meet Air Force technical requirements. A prototype was designed, developed, and tested through a subcontract with Reimers Consultants, Falls Church, Virginia. This report describes the technical requirements, a detailed technical description of the unit, and the unmanned test procedures and results. The unmanned testing demonstrate that the prototype SCBA meets all performance requirements, except for weight.more » The fully charged prototype weights 34 pounds, the maximum acceptable weight is 30 pounds. With the other performance requirements either met or exceeded, manned testing of the SCBA can proceed.« less

  6. Scuba Diving and Kinesiology: Development of an Academic Program

    ERIC Educational Resources Information Center

    Kovacs, Christopher R.; Walter, Daniel

    2015-01-01

    The use of scuba diving as a recreational activity within traditional university instructional programs has been well established. Departments focusing on kinesiology, physical education, or exercise science have often provided scuba diving lessons as part of their activity-based course offerings. However, few departments have developed an…

  7. Dive into Scuba

    ERIC Educational Resources Information Center

    Coelho, Jeffrey; Fielitz, Lynn R.

    2006-01-01

    Scuba is a unique physical education activity that middle school and high school students can experience in physical education to provide them with the basic skills needed to enjoy the sport for many years to come. This article describes the basic scuba diving equipment, proper training and certification for instructors and students, facilities,…

  8. The SCUBA Data Reduction Pipeline: ORAC-DR at the JCMT

    NASA Astrophysics Data System (ADS)

    Jenness, Tim; Economou, Frossie

    The ORAC data reduction pipeline, developed for UKIRT, has been designed to be a completely general approach to writing data reduction pipelines. This generality has enabled the JCMT to adapt the system for use with SCUBA with minimal development time using the existing SCUBA data reduction algorithms (Surf).

  9. Safe Inner Ear Gas Tensions for Switch from Helium to Air Breathing During Decompression

    DTIC Science & Technology

    2013-04-01

    heliox to air during decompression is that it is associated with symptoms of injury to the vestibulocochlear apparatus (inner ear) such as vertigo ...dive. Vertigo , nausea, and other symptoms consistent with injury to the vestibulocochlear apparatus have been described during 1200 feet sea water (fsw...and undulating nausea. No other symptoms. No numbness, tingling, weakness or vertigo . Symptoms attributed to large amount of food <supplied>cold pizza

  10. Presumed Arterial Gas Embolism After Breath-Hold Diving in Shallow Water.

    PubMed

    Harmsen, Stefani; Schramm, Dirk; Karenfort, Michael; Christaras, Andreas; Euler, Michael; Mayatepek, Ertan; Tibussek, Daniel

    2015-09-01

    Dive-related injuries are relatively common, but almost exclusively occur in recreational or scuba diving. We report 2 children with acute central nervous system complications after breath-hold diving. A 12-year-old boy presented with unilateral leg weakness and paresthesia after diving beneath the water surface for a distance of ∼25 m. After ascent, he suddenly felt extreme thoracic pain that resolved spontaneously. Neurologic examination revealed right leg weakness and sensory deficits with a sensory level at T5. Spinal MRI revealed a nonenhancing T2-hyperintense lesion in the central cord at the level of T1/T2 suggesting a spinal cord edema. A few weeks later, a 13-year-old girl was admitted with acute dizziness, personality changes, confusion, and headache. Thirty minutes before, she had practiced diving beneath the water surface for a distance of ∼25 m. After stepping out, she felt sudden severe thoracic pain and lost consciousness. Shortly later she reported headache and vertigo, and numbness of the complete left side of her body. Neurologic examination revealed reduced sensibility to all modalities, a positive Romberg test, and vertigo. Cerebral MRI revealed no pathologic findings. Both children experienced a strikingly similar clinical course. The chronology of events strongly suggests that both patients were suffering from arterial gas embolism. This condition has been reported for the first time to occur in children after breath-hold diving beneath the water surface without glossopharyngeal insufflation. Copyright © 2015 by the American Academy of Pediatrics.

  11. Lung function after cold-water dives with a standard scuba regulator or full-face-mask during wintertime.

    PubMed

    Uhlig, Florian; Muth, Claus-Martin; Tetzlaff, Kay; Koch, Andreas; Leberle, Richard; Georgieff, Michael; Winkler, Bernd E

    2014-06-01

    Full-face-masks (FFM) prevent the diver's face from cold and can support nasal breathing underwater. The aim of the study was to evaluate the effect of the use of FFMs on lung function and wellbeing. Twenty-one, healthy, non-asthmatic divers performed two cold-water dives (4⁰C, 25 min, 10 metres' depth) - one with a FFM and the other with a standard scuba regulator (SSR). Spirometry was performed before and after each dive and well-being and cold sensation were assessed after the dives. Significant decreases in forced vital capacity (FVC), forced expiratory volume in one second (FEV₁) and midexpiratory flow at 75% of FVC (MEF₇₅) occurred after both FFM and SSR dives. Changes in FVC and FEV₁ did not differ significantly between FFM and SSR dives. However, the mid-expiratory flows measured at 50% and 25% of FVC (MEF₅₀ and MEF₂₅) were significantly lower 10 minutes after the FFM dive compared to 10 minutes after the SSR dive. The wellbeing and cold sensation of the divers were significantly improved with FFM dives compared to SSR dives. Cold-water dives during wintertime can be associated with airway narrowing. During cold-water dives, the use of a FFM appears to reduce the cold sensation and enhance the well-being of the divers. However, a FFM does not appear to prevent airway narrowing in healthy, non-asthmatic subjects.

  12. STS-46 MS Hoffman and MS Chang-Diaz wear masks during pre-breathe on OV-104

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Mission Specialist (MS) and Payload Commander (PLC) Jeffrey A. Hoffman and MS Franklin R. Chang-Diaz, wearing breathing apparatus masks, pose on the forward flight deck of Atlantis, Orbiter Vehicle (OV) 104, during pre-breathe session. With the possibility of an extravehicular activity (EVA) being added to the STS-46 agenda, the astronauts reported to this station and began the 'pre-breathe' process when problems developed during the extension of the Tethered Satellite System 1 (TSS-1). When the human body is exposed to a sudden decrease in atmospheric pressure (for instance, from the 10.2 ppsi in the crew cabin to the 4.5 ppsi of the extravehicular mobility unit (EMU)), nitrogen traces in the bloodstream will expand. This expansion can create tiny bubbles and potential for the 'bends'. In order to lessen the effect, an astronaut must 'pre-breathe' pure oxygen (the same pure oxygen he will breathe in the suit) to help 'purge' nitrogen from his bloodstream before exerting himself

  13. New operational technology of intrauterine ventilation the fetus lungs by breathing gas

    NASA Astrophysics Data System (ADS)

    Urakov, A. L.; Nikityuk, D. B.; Urakova, N. A.; Kasankin, A. A.; Chernova, L. V.; Dementiev, V. B.

    2015-11-01

    New operational technology for elimination intrauterine hypoxia and asphyxia of the fetus using endoscopic artificial ventilation lungs by respiratory gas was developed. For intrauterine ventilation of fetal lung it is proposed to enter into the uterus a special breathing mask and wear it on the head of the fetus using the original endoscopic technology. The breathing mask, developed by us is connected with external breathing apparatus with a hose. The device is called "intrauterine aqualung". Intrauterine aqualung includes a ventilator and breathing circuit with a special fold-out breathing mask that is put on inside the uterus on the head of fetus like a mesh hat. Controlled by ultrasound the technology of the introduction of the mask inside of the uterus through the natural opening in the cervix and technology of putting on the respiratory mask on the head of the fetus with its head previa were developed. The technology intrauterine ventilation of the fetus lungs by respiratory gas was developed.

  14. 30 CFR 49.6 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Metal and Nonmetal Mines § 49.6 Equipment and... sufficient to sustain each team for eight hours while using the breathing apparatus during rescue operations...

  15. 30 CFR 49.6 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Metal and Nonmetal Mines § 49.6 Equipment and... sufficient to sustain each team for eight hours while using the breathing apparatus during rescue operations...

  16. 30 CFR 49.6 - Equipment and maintenance requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... TRAINING MINE RESCUE TEAMS Mine Rescue Teams for Underground Metal and Nonmetal Mines § 49.6 Equipment and... sufficient to sustain each team for eight hours while using the breathing apparatus during rescue operations...

  17. 29 CFR 1915.5 - Incorporation by reference.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., Quincy, MA 02269-9101: (i) NFPA 1981-2002 Standard on Open-Circuit Self-Contained Breathing Apparatus for...-, Medium-, and High-Expansion Foam, IBR approved for § 1915.507(d)(3). (xiv) NFPA 17-2002, Standard for Dry...

  18. 29 CFR 1915.5 - Incorporation by reference.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., Quincy, MA 02269-9101: (i) NFPA 1981-2002 Standard on Open-Circuit Self-Contained Breathing Apparatus for...-, Medium-, and High-Expansion Foam, IBR approved for § 1915.507(d)(3). (xiv) NFPA 17-2002, Standard for Dry...

  19. 29 CFR 1915.5 - Incorporation by reference.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., Quincy, MA 02269-9101: (i) NFPA 1981-2002 Standard on Open-Circuit Self-Contained Breathing Apparatus for...-, Medium-, and High-Expansion Foam, IBR approved for § 1915.507(d)(3). (xiv) NFPA 17-2002, Standard for Dry...

  20. 49 CFR 176.164 - Fire precautions and firefighting.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vessel must have two sets of breathing apparatus and a power-operated fire pump, which, together with its source of power and sea connections, must be located outside the machinery space. [Amdt. 176-30, 55 FR...

  1. Beginning Skin and Scuba Diving, Physical Education: 5551.69.

    ERIC Educational Resources Information Center

    Roberts, Millie

    This course outline is a guide for teaching the principles and basic fundamentals of beginning skin and scuba diving in grades 7-12. The course format includes lectures, skills practice, films, and tests that focus on mastery of skills and understanding correct usage of skin and scuba equipment. Course content includes the following: (a) history,…

  2. Effect of wearing personal protective clothing and self-contained breathing apparatus on heart rate, temperature and oxygen consumption during stepping exercise and live fire training exercises.

    PubMed

    Bruce-Low, S S; Cotterrell, D; Jones, G E

    2007-01-15

    Fire fighter breathing apparatus instructors (BAIs) must possess the ability to respond to both the extrinsic stress of a high temperature environment and the intrinsic stress from wearing personal protective equipment (PPE) and self-contained breathing apparatus (SCBA), repeatedly and regularly, whilst training recruits in live fire training exercises (LFTEs). There are few previous investigations on BAIs in hot environments such as LFTEs, since the main research focus has been on regular fire fighters undertaking exercises in temperate or fire conditions at a moderate to high exercise intensity. In this study, the intrinsic cardiovascular stress effects of wearing PPE + SCBA were first investigated using a step test whilst wearing gym kit (control), weighted gym kit (a rucksack weighted to the equivalent of PPE + SCBA) and full PPE + SCBA (weight plus the effects of protective clothing). The extrinsic effects of the very hot environment were investigated in BIAs in LFTEs compared to mock fire training exercises (MFTEs), where the fire was not ignited. There was an increase in heart rate due to the modest workload imposed on the BAIs through carrying out the MFTEs (25.0 (18.7)%) compared to resting. However, when exposed to fire during the LFTEs, heat storage appears to be significant as the heart rate increased by up to 39.8 (+/-20.1)% over that of the mock LFTEs at temperate conditions. Thus, being able to dissipate heat from the PPE is particularly important in reducing the cardiovascular responses for BAIs during LFTEs.

  3. 46 CFR 154.1415 - Air compressor.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Air compressor. 154.1415 Section 154.1415 Shipping COAST... Equipment § 154.1415 Air compressor. Each vessel must have an air compressor to recharge the bottles for the air-breathing apparatus. ...

  4. 46 CFR 154.1415 - Air compressor.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Air compressor. 154.1415 Section 154.1415 Shipping COAST... Equipment § 154.1415 Air compressor. Each vessel must have an air compressor to recharge the bottles for the air-breathing apparatus. ...

  5. 46 CFR 154.1415 - Air compressor.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Air compressor. 154.1415 Section 154.1415 Shipping COAST... Equipment § 154.1415 Air compressor. Each vessel must have an air compressor to recharge the bottles for the air-breathing apparatus. ...

  6. 46 CFR 154.1415 - Air compressor.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Air compressor. 154.1415 Section 154.1415 Shipping COAST... Equipment § 154.1415 Air compressor. Each vessel must have an air compressor to recharge the bottles for the air-breathing apparatus. ...

  7. 46 CFR 154.1415 - Air compressor.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 5 2011-10-01 2011-10-01 false Air compressor. 154.1415 Section 154.1415 Shipping COAST... Equipment § 154.1415 Air compressor. Each vessel must have an air compressor to recharge the bottles for the air-breathing apparatus. ...

  8. Scuba: scalable kernel-based gene prioritization.

    PubMed

    Zampieri, Guido; Tran, Dinh Van; Donini, Michele; Navarin, Nicolò; Aiolli, Fabio; Sperduti, Alessandro; Valle, Giorgio

    2018-01-25

    The uncovering of genes linked to human diseases is a pressing challenge in molecular biology and precision medicine. This task is often hindered by the large number of candidate genes and by the heterogeneity of the available information. Computational methods for the prioritization of candidate genes can help to cope with these problems. In particular, kernel-based methods are a powerful resource for the integration of heterogeneous biological knowledge, however, their practical implementation is often precluded by their limited scalability. We propose Scuba, a scalable kernel-based method for gene prioritization. It implements a novel multiple kernel learning approach, based on a semi-supervised perspective and on the optimization of the margin distribution. Scuba is optimized to cope with strongly unbalanced settings where known disease genes are few and large scale predictions are required. Importantly, it is able to efficiently deal both with a large amount of candidate genes and with an arbitrary number of data sources. As a direct consequence of scalability, Scuba integrates also a new efficient strategy to select optimal kernel parameters for each data source. We performed cross-validation experiments and simulated a realistic usage setting, showing that Scuba outperforms a wide range of state-of-the-art methods. Scuba achieves state-of-the-art performance and has enhanced scalability compared to existing kernel-based approaches for genomic data. This method can be useful to prioritize candidate genes, particularly when their number is large or when input data is highly heterogeneous. The code is freely available at https://github.com/gzampieri/Scuba .

  9. 46 CFR 154.1400 - Safety equipment: All vessels.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CERTAIN BULK DANGEROUS CARGOES SAFETY STANDARDS FOR SELF-PROPELLED VESSELS CARRYING BULK LIQUEFIED GASES Design, Construction and Equipment Safety...: (1) Six self-contained, pressure-demand-type, air-breathing apparatus approved by the Mining...

  10. 29 CFR 1918.93 - Hazardous atmospheres and substances (See also § 1918.2).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...; § 1918.94(e), Catch of menhaden and similar species of fish. (b) Determination of the hazard. When the...-contained breathing apparatus which shall be used for entry. (4) To prevent inadvertent employee entry into...

  11. Reaction time following yoga bellows-type breathing and breath awareness.

    PubMed

    Telles, Shirley; Yadav, Arti; Gupta, Ram Kumar; Balkrishna, Acharya

    2013-08-01

    The reaction time (RT) was assessed in two groups of healthy males, yoga group (M age = 29.0 yr.) and non-yoga or control group (M age = 29.0 yr.), with 35 participants each. The yoga group had an average experience of 6 months, while the control group was yoga-naïve. The yoga group was assessed in two sessions, (i) bhastrika pranayama or bellows breathing and (ii) breath awareness, while the control group had a single control session. The two experimental sessions, one with each type of breathing, and the control session consisted of pre- (5 min.), during (18 min.), and post-session epochs (5 min.). Assessments were made in the pre- and post-session epochs using a Multi-Operational Apparatus for Reaction Time. Following 18 min. of bhastrika pranayama there was a statistically significant reduction in number of anticipatory responses compared to before the practice. This suggests that the immediate effect of bhastrika pranayama is to inhibit unnecessary responding to stimuli.

  12. Possible central nervous system oxygen toxicity seizures among US recreational air or enriched air nitrox open circuit diving fatalities 2004-2013.

    PubMed

    Buzzacott, P; Denoble, P J

    2017-01-01

    The first diver certification programme for recreational 'enriched air nitrox' (EAN) diving was released in 1985. Concerns were expressed that many EAN divers might suffer central nervous system (CNS) oxygen toxicity seizures and drown. US fatalities on open-circuit scuba occurring between 2004-2013, where the breathing gas was either air or EAN, were identified. Causes of death and preceding circumstances were examined by a medical examiner experienced in diving autopsies. Case notes were searched for witnessed seizures at elevated partial pressures of oxygen. The dataset comprised 344 air divers (86%) and 55 divers breathing EAN (14%). EAN divers' fatal dives were deeper than air divers' (28 msw vs 18 msw, p < 0.0001). Despite this, of the 249 cases where a cause of death was established, only three EAN divers were considered to have possibly died following CNS oxygen toxicity seizures at depth (ppO2 132, 142 and 193 kPa). The analysis of recreational diving fatalities in the US over 10 years found just one death likely from CNS oxygen toxicity among EAN divers. A further two possible, although unlikely, cases were also found. Fears of commonplace CNS oxygen toxicity seizures while EAN diving have not apparently been realized.

  13. Effects of depth and chest volume on cardiac function during breath-hold diving.

    PubMed

    Marabotti, Claudio; Scalzini, Alessandro; Cialoni, Danilo; Passera, Mirko; Ripoli, Andrea; L'Abbate, Antonio; Bedini, Remo

    2009-07-01

    Cardiac response to breath-hold diving in human beings is primarily characterized by the reduction of both heart rate and stroke volume. By underwater Doppler-echocardiography we observed a "restrictive/constrictive" left ventricular filling pattern compatible with the idea of chest squeeze and heart compression during diving. We hypothesized that underwater re-expansion of the chest would release heart constriction and normalize cardiac function. To this aim, 10 healthy male subjects (age 34.2 +/- 10.4) were evaluated by Doppler-echocardiography during breath-hold immersion at a depth of 10 m, before and after a single maximal inspiration from a SCUBA device. During the same session, all subjects were also studied at surface (full-body immersion) and at 5-m depth in order to better characterize the relationship of echo-Doppler pattern with depth. In comparison to surface immersion, 5-m deep diving was sufficient to reduce cardiac output (P = 0.042) and increase transmitral E-peak velocity (P < 0.001). These changes remained unaltered at a 10-m depth. Chest expansion at 10 m decreased left ventricular end-systolic volume (P = 0.024) and increased left ventricular stroke volume (P = 0.024). In addition, it decreased transmitral E-peak velocity (P = 0.012) and increased deceleration time of E-peak (P = 0.021). In conclusion the diving response, already evident during shallow diving (5 m) did not progress during deeper dives (10 m). The rapid improvement in systolic and diastolic function observed after lung volume expansion is congruous with the idea of a constrictive effect on the heart exerted by chest squeeze.

  14. Divers revisited: The ventilatory response to carbon dioxide in experienced scuba divers.

    PubMed

    Earing, Christopher Matthew Norton; McKeon, Damian John; Kubis, Hans-Peter

    2014-05-01

    To investigate the ventilatory response to CO2 in hyperoxia, hypoxia, and during exercise amongst experienced scuba divers and matched controls. Two studies were performed. The first investigated the CO2 sensitivity in rest and exercise using CO2 rebreathing in hyperoxia at a workload typical for diving with divers (n = 11) and controls (n = 11). The second study examined the respiratory drive of divers (n = 10) and controls (n = 10) whilst breathing four different gas mixtures balanced with N2 (ambient air; 25% O2/6% CO2; 13% O2; 13% O2/6% CO2) to assess the combined response to hypercapnia and moderate hypoxia. Exercise at a load typical for diving was found to have no effect on the ventilatory sensitivity to CO2 in divers (rest: 1.49 ± 0.33; exercise: 1.22 ± 0.55 [l/min × mmHg(-1)]) and controls (rest: 2.08 ± 0.71; exercise: 2.05 ± 0.98 [l/min × mmHg(-1)]) while differences in sensitivity remained between the groups. Inhalation of the four gas mixtures revealed the tested oxygen pressures caused no significant alteration in the ventilatory sensitivity to CO2 in divers and controls. Experienced divers possess a lower ventilatory response to CO2 which was not affected by exercise or the tested oxygen pressures suggesting a dominant adaptation of central CO2 sensitivity. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Effects of successive air and nitrox dives on human vascular function.

    PubMed

    Marinovic, Jasna; Ljubkovic, Marko; Breskovic, Toni; Gunjaca, Grgo; Obad, Ante; Modun, Darko; Bilopavlovic, Nada; Tsikas, Dimitrios; Dujic, Zeljko

    2012-06-01

    SCUBA diving is regularly associated with asymptomatic changes in cardiac, pulmonary and vascular function. The aim of this study was to evaluate the changes in vascular/endothelial function following SCUBA diving and to assess the potential difference between two breathing gases: air and nitrox 36 (36% oxygen and 64% nitrogen). Ten divers performed two 3-day diving series (no-decompression dive to 18 m with 47 min bottom time with air and nitrox, respectively), with 2 weeks pause in between. Arterial/endothelial function was assessed using SphygmoCor and flow-mediated dilation measurements, and concentration of nitrite before and after diving was determined in venous blood. Production of nitrogen bubbles post-dive was assessed by ultrasonic determination of venous gas bubble grade. Significantly higher bubbling was found after all air dives as compared to nitrox dives. Pulse wave velocity increased slightly (~6%), significantly after both air and nitrox diving, indicating an increase in arterial stiffness. However, augmentation index became significantly more negative after diving indicating smaller wave reflection. There was a trend for post-dive reduction of FMD after air dives; however, only nitrox diving significantly reduced FMD. No significant differences in blood nitrite before and after the dives were found. We found that nitrox diving affects systemic/vascular function more profoundly than air diving by reducing FMD response, most likely due to higher oxygen load. Both air and nitrox dives increased arterial stiffness, but decreased wave reflection suggesting a decrease in peripheral resistance due to exercise during diving. These effects of nitrox and air diving were not followed by changes in plasma nitrite.

  16. Determinants of arterial gas embolism after scuba diving.

    PubMed

    Ljubkovic, Marko; Zanchi, Jaksa; Breskovic, Toni; Marinovic, Jasna; Lojpur, Mihajlo; Dujic, Zeljko

    2012-01-01

    Scuba diving is associated with breathing gas at increased pressure, which often leads to tissue gas supersaturation during ascent and the formation of venous gas emboli (VGE). VGE crossover to systemic arteries (arterialization), mostly through the patent foramen ovale, has been implicated in various diving-related pathologies. Since recent research has shown that arterializations frequently occur in the absence of cardiac septal defects, our aim was to investigate the mechanisms responsible for these events. Divers who tested negative for patent foramen ovale were subjected to laboratory testing where agitated saline contrast bubbles were injected in the cubital vein at rest and exercise. The individual propensity for transpulmonary bubble passage was evaluated echocardiographically. The same subjects performed a standard air dive followed by an echosonographic assessment of VGE generation (graded on a scale of 0-5) and distribution. Twenty-three of thirty-four subjects allowed the transpulmonary passage of saline contrast bubbles in the laboratory at rest or after a mild/moderate exercise, and nine of them arterialized after a field dive. All subjects with postdive arterialization had bubble loads reaching or exceeding grade 4B in the right heart. In individuals without transpulmonary passage of saline contrast bubbles, injected either at rest or after an exercise bout, no postdive arterialization was detected. Therefore, postdive VGE arterialization occurs in subjects that meet two criteria: 1) transpulmonary shunting of contrast bubbles at rest or at mild/moderate exercise and 2) VGE generation after a dive reaches the threshold grade. These findings may represent a novel concept in approach to diving, where diving routines will be tailored individually.

  17. 27. VIEW OF UNDERWATER WELDING/SCUBA ROOM, FIRST FLOOR, LOOKING NORTH. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    27. VIEW OF UNDERWATER WELDING/SCUBA ROOM, FIRST FLOOR, LOOKING NORTH. Former location of tank indicated by circular ridge in linoleum at bottom right, and by framing of second floor at top right. Silhouettes of driver and two sharks on the floor are associated with the use of this building for scuba training. - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  18. The SCUBA map reduction cookbook

    NASA Astrophysics Data System (ADS)

    Sandell, G.; Jessop, N.; Jenness, T.

    This cookbook tells you how to reduce and analyze maps obtained with SCUBA using the off-line SCUBA reduction package, SURF, and the Starlink KAPPA, Figaro, GAIA and CONVERT applications. The easiest way of using these packages is to run-up ORAC-DR, a general purpose pipeline for reducing data from any telescope. A set of data reduction recipes are available to ORAC-DR for use when working with scuba maps, these recipes utilize the SURF and KAPPA packages. This cookbook makes no attempts to explain why and how, for that there is a comprehensive Starlink User Note 216 which properly documents all the software tasks in SURF, which should be consulted for those who need to know details of a task, or how the task really works.

  19. Scuba Science.

    ERIC Educational Resources Information Center

    Glickstein, Neil

    2000-01-01

    Introduces an integrated unit on scuba science. Studies oxygen in kinetic theory, Boyle's law, Charles's law, Dalton's law, human circulatory and respiratory systems, and diving dangers such as decompression sickness. (YDS)

  20. Feasibility Study of 2000 Foot Underwater Breathing Apparatus

    DTIC Science & Technology

    1978-08-14

    It was found that a backpack mounted scrubber , with integral gas heating and P02 control, with a fan-driven circulation system, could be inte’faced...PROGRAMS.............................5 K BACKPACK FAN- SCRUBBER ...................................... . 5 The Backpack...9 The Scrubber .................................... .......... 9 Gas Heating ......................................... ..... 9 The Helmet

  1. JCMT in the Post-Herschel ERA of Alma

    NASA Astrophysics Data System (ADS)

    Johnstone, Doug

    2013-07-01

    The James Clerk Maxwell Telescope (JCMT), with a 15m dish, is the largest single-dish astronomical telescope in the world designed specifically to operate in the sub-mm wavelength regime. The JCMT is located close to the summit of Mauna Kea, Hawaii, at an altitude of 4092m. The most recent addition to the JCMT's suite of instruments is the 10,000 bolometer sub-mm continuum instrument: SCUBA-2. SCUBA-2 operates simultaneously with 7' x7' foot print sub-arrays at both 450 and 850-microns. SCUBA-2's wide field surveying potential, combined with a 65% shared view of the sky from both sites, makes it the ideal instrument to provide complementary data for the ALMA Project. Furthermore, the SCUBA-2 sub-millimetre wavelength coverage and angular resolution complement existing Herschel observations. A set of comprehensive surveys of the submillimetre sky is underway at the James Clerk Maxwell Telescope (JCMT) using SCUBA-2 and HARP, a heterodyne array receiver operating between 325 and 375 GHz. The JCMT Legacy Survey (JLS) is comprised of seven survey projects, and ranges in scope from the study of nearby debris disk systems, the study of star formation in nearby molecular cloud systems and more distant structures in our Galactic Plane, to the structure and composition of galaxies in our local neighbourhood and the number and evolution of submillimetre galaxies at high redshifts in the early Universe. In addition to the JLS, the COHR survey is imaging the Galactic plane in CO (3-2) and a JAC Staff-led project is using SCUBA-2 to survey the Galactic Centre. This poster highlights the significant survey capabilities of SCUBA-2 and HARP and reveals the continuing importance of the JCMT in a post-Herschel, ALMA world.

  2. Central Nervous System Oxygen Toxicity in Closed-Circuit Scuba Divers

    DTIC Science & Technology

    1986-03-01

    CENTRAL NERVOUS SYSTEM OXYGEN TOXICITY IN CLOSED -CIRCUIT SCUBA DIVERS III By F. K. Butler, Jr., LCDR, MC, USN NAVY EXPERIMENTAL DIVING UNIT DTIC...PANAMA CITY. FLORIDA 321407 IN. aLV OMW Vol NAVY EXPERIMENTAL DIVING UNIT REPORT NO. 5-86 CENTRAL NERVOUS SYSTEM OXYGEN TOXICITY IN CLOSED -CIRCUIT SCUBA...BUTLER, Jr. J . .d.M. HAMILTON LCDR, MC, USK CDR, MC, USK CDR, USKN Medical Research Officer Senior Medical Officer Comanding Officer UNCLASSIFIED 4

  3. 49 CFR 194.117 - Training.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Training. 194.117 Section 194.117 Transportation... Response Plans § 194.117 Training. (a) Each operator shall conduct training to ensure that: (1) All... of equipment, fire suits, and breathing apparatus. (b) Each operator shall maintain a training record...

  4. 49 CFR 194.117 - Training.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 3 2011-10-01 2011-10-01 false Training. 194.117 Section 194.117 Transportation... Response Plans § 194.117 Training. (a) Each operator shall conduct training to ensure that: (1) All... of equipment, fire suits, and breathing apparatus. (b) Each operator shall maintain a training record...

  5. Rescue Manual. Module 2.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. Instructional Materials Lab.

    This learner manual for rescuers covers the current techniques or practices required in the rescue service. The second of 10 modules contains 5 chapters: (1) patient care and handling techniques; (2) rescue carries and drags; (3) emergency vehicle operations; (4) self-contained breathing apparatus; and (5) protective clothing. Key points, an…

  6. 46 CFR 195.35-20 - Spare charges.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Spare charges. 195.35-20 Section 195.35-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS VESSEL CONTROL... recharge shall be carried for each self-contained breathing apparatus, and a complete set of spare...

  7. The SCUBA-2 Data Reduction Cookbook

    NASA Astrophysics Data System (ADS)

    Thomas, Holly S.; Currie, Malcolm J.

    This cookbook provides a short introduction to Starlink facilities, especially SMURF, the Sub-Millimetre User Reduction Facility, for reducing, displaying, and calibrating SCUBA-2 data. It describes some of the data artefacts present in SCUBA-2 time-series and methods to mitigate them. In particular, this cookbook illustrates the various steps required to reduce the data; and gives an overview of the Dynamic Iterative Map-Maker, which carries out all of these steps using a single command controlled by a configuration file. Specialised configuration files are presented.

  8. [Research and development of portable hypertension therapeutic apparatus based on biofeedback mechanism].

    PubMed

    Huang, Rong; He, Hongmei; Pi, Xitian; Diao, Ziji; Zhao, Suwen

    2014-06-01

    Non-drug treatment of hypertension has become a research hotspot, which might overcome the heavy economic burden and side effects of drug treatment for the patients. Because of the good treatment effect and convenient operation, a new treatment based on slow breathing training is increasingly becoming a kind of physical therapy for hypertension. This paper explains the principle of hypertension treatment based on slow breathing training method, and introduces the overall structure of the portable blood pressure controlling instrument, including breathing detection circuit, the core control module, audio module, memory module and man-machine interaction module. We give a brief introduction to the instrument and the software in this paper. The prototype testing results showed that the treatment had a significant effect on controlling the blood pressure.

  9. NASA Developments in Personnel Protective Equipment

    NASA Technical Reports Server (NTRS)

    Graf, John

    2015-01-01

    NASA has some unique and challenging PPE needs: there are credible threats to air quality (fire, ammonia leak, hydrazine leak)that require a contingency breathing apparatus that operates for many hours - but there is not enough space or up-mass to provide supplied air tanks. We cannot use "Scott Air Tanks" commonly used by firefighters and other first responders. NASA has developed a respirator based emergency breathing device. It uses a "one size fits everybody in the astronaut corps" hooded mask with excellent chemical permeability and fire resistance properties, and a filtering respirator cartridge that protects the wearer from ammonia leaks, hydrazine leaks, or products of combustion. If you need a small, lightweight emergency breathing system that lasts longer than a supplied air system, we should meet and learn if NASA sponsored technology development can help.

  10. Benefit from NASA

    NASA Image and Video Library

    2004-04-15

    Firefighters are like astronauts. They both face dangerous, even hostile environments such as a building full of fire and the vacuum of space. They are both get breathing air from tanks on their backs. Early in the 1970's, NASA began working to improve firefighter breathing systems, which had hardly changed since the 1940s. NASA's Johnson Space Center conducted a 4-year program that applied technology from the portable life support systems used by Apollo astronauts on the moon. The new breathing system is made up of an air bottle, a frame and harness, a face mask, and a warning device. The new system weighs less than 20 pounds, one-third less than the old gear. The new air bottle provides 30 minutes of breathing air, as much as the old system. Like a good hiker's backpack, the new system puts the weight on the firefighter's hips rather than the shoulders. The face mask provides better visibility and the warning device lets the firefighter know when air in the bottle is low. Though they have made many design modifications and refinements, manufacturers of breathing apparatus still incorporate the original NASA technology.

  11. 46 CFR 96.35-20 - Spare charges.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 4 2011-10-01 2011-10-01 false Spare charges. 96.35-20 Section 96.35-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS VESSEL CONTROL AND... carried for each self-contained breathing apparatus, and a complete set of spare batteries shall be...

  12. 46 CFR 77.35-20 - Spare charges.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Spare charges. 77.35-20 Section 77.35-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS VESSEL CONTROL AND MISCELLANEOUS... for each self-contained breathing apparatus, and a complete set of spare batteries shall be carried...

  13. 46 CFR 77.30-15 - Spare charges.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 3 2010-10-01 2010-10-01 false Spare charges. 77.30-15 Section 77.30-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS VESSEL CONTROL AND MISCELLANEOUS... carried for each gas mask and self-contained breathing apparatus. The spare charge shall be stowed in the...

  14. 46 CFR 77.35-20 - Spare charges.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Spare charges. 77.35-20 Section 77.35-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS VESSEL CONTROL AND MISCELLANEOUS... for each self-contained breathing apparatus, and a complete set of spare batteries shall be carried...

  15. 46 CFR 77.30-15 - Spare charges.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 3 2011-10-01 2011-10-01 false Spare charges. 77.30-15 Section 77.30-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS VESSEL CONTROL AND MISCELLANEOUS... carried for each gas mask and self-contained breathing apparatus. The spare charge shall be stowed in the...

  16. Emergency Mask OBT

    NASA Image and Video Library

    2015-07-28

    ISS044E025035 (07/29/2015) --- NASA astronaut Kjell Lindgren wears protective breathing apparatus that would be used in the unlikely event of a fire or hazardous chemical leak inside the pressurized air volume of the International Space Station. Familiarization of safety and emergency equipment is standard practice for all newly arrived crew members.

  17. U.S. Navy Unmanned Test Methods and Performance Limits for Underwater Breathing Apparatus

    DTIC Science & Technology

    2015-06-01

    in liters per minute (STPD) ?̇?2 Metabolic oxygen consumption in liters per minute (STPD) max Maximum flow rate ?̇? Ventilation , first time...8-2 8.1.3 Oxygen consumption ... OXYGEN CONSUMPTION SIMULATION ........................................................................... 9-1 CHAPTER 9. NEDU TM 15-01 vii 9-1

  18. An examination of two emergency breathing aids for use during helicopter underwater escape.

    PubMed

    Tipton, M J; Franks, C M; Sage, B A; Redman, P J

    1997-10-01

    There is a paucity of published work in which the performance of Emergency Underwater Breathing Aids (EUBA) has been examined in the wide range of scenarios in which helicopter underwater escape may be necessary. In the present investigation two EUBA were examined: the Air Pocket (AP) rebreather and the Short Term Air Supply System (STASS) mini SCUBA set. Young, healthy male subjects undertook simple simulated helicopter underwater escapes in water at 15 degrees C and/or 5 degrees C. During the immersions the subjects attempted to remain submerged for 60 s while traversing back and forth along a ladder secured at a depth of 1.25 m. At each temperature the subjects used AP and STASS twice. The subjects were dressed in the Royal Navy winter sea helicopter aircrew equipment assembly and an aircrew helmet. Both AP and STASS significantly extended the underwater survival time of individuals when compared to their maximum breath-hold time (BHT). It is clear from the measurements made of gas concentrations in AP; the volume of air used from STASS; and subjective responses, that the 60-s submersions were achieved more easily with STASS than AP. It is concluded that in conditions similar to those of the present experiment STASS will give a longer underwater duration than AP, but this benefit must be offset against the possible risk of pulmonary barotrauma associated with the use of STASS, as well as increased training and maintenance costs. Irrespective of the EUBA which is provided, in-water training, preferably including exposure to cold water, will significantly improve the ability of an individual to use it.

  19. The influence of dilution on the offline measurement of exhaled nitric oxide.

    PubMed

    MacBean, Victoria; Pooranampillai, Dharmika; Howard, Catherine; Lunt, Alan; Greenough, Anne

    2018-02-26

    Measurement of fractional exhaled nitric oxide (FeNO) is used to determine the presence and severity of eosinophilic airway inflammation in asthma and other wheezing illnesses. The gold standard of online measurement during a single prolonged exhalation is not suitable for use in young children. The international guidelines for offline measurements recommend collection of exhaled gas in an appropriate reservoir for later analysis in young children. The apparatus required for gas collection, however, creates dead space within the system, which may result in sample dilution and hence inaccuracy. Our objective was to investigate the effect such dilution might have on the accuracy of offline FeNO by comparing the results to online results. Thirty-five adult subjects without respiratory disease underwent online measurement of FeNO and, thereafter, undertook offline FeNO measurements via exhalation into a collection reservoir using one, five or ten inhalation-exhalation cycles. Fifteen of the subjects also exhaled using the five-breath technique via apparatus with additional dead space. An equation incorporating dead space volume and the number of breaths was used to predict the degree of dilution; the predicted results were compared to the measured results. The median (IQR) FeNO from a one-breath technique (22 (15-28) ppb was not significantly different to online values (19 (12-27) ppb, p  =  1.00), but the results from the five-breath technique (11 (4-19) ppb, p  <  0.0001), the ten-breath technique (6 (4-15) ppb, p  <  0.0001) and the additional dead space experiment (6 (3-8) ppb, p  =  0.0006) were significantly lower than online FeNO. Measured values were consistently significantly different to those predicted by the dilution equation, even when incorporating the exact exhaled volume of gas. Offline FeNO results may be inaccurate when subjects are unable to fill the collection reservoir with a single exhalation, thus the technique may not be suitable for preschool children.

  20. ORAC-DR -- SCUBA-2 Pipeline Data Reduction

    NASA Astrophysics Data System (ADS)

    Gibb, Andrew G.; Jenness, Tim

    The ORAC-DR data reduction pipeline is designed to reduce data from many different instruments. This document describes how to use ORAC-DR to process data taken with the SCUBA-2 instrument on the James Clerk Maxwell Telescope.

  1. 42 CFR 84.102 - Man test 6; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.102 Man test 6; requirements....

  2. 42 CFR 84.103 - Man tests; performance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; performance requirements. 84.103 Section 84.103 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.103 Man tests;...

  3. 42 CFR 84.99 - Man tests; testing conditions; general requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests; testing conditions; general requirements. 84.99 Section 84.99 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.99...

  4. 42 CFR 84.101 - Man test 5; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.101 Man test 5; requirements....

  5. The Relationship between Physical Activity and Thermal Protective Clothing on Functional Balance in Firefighters

    ERIC Educational Resources Information Center

    Kong, Pui W.; Suyama, Joe; Cham, Rakie; Hostler, David

    2012-01-01

    We investigated the relationship between baseline physical training and the use of firefighting thermal protective clothing (TPC) with breathing apparatus on functional balance. Twenty-three male firefighters performed a functional balance test under four gear/clothing conditions. Participants were divided into groups by physical training status,…

  6. 42 CFR 84.91 - Breathing resistance test; exhalation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 25 mm. (1 inch) water-column height. (c) The exhalation resistance of pressure-demand apparatus shall not exceed the static pressure in the facepiece by more than 51 mm. (2 inches) water-column height. (d) The static pressure (at zero flow) in the facepiece shall not exceed 38 mm. (1.5 inches) water-column...

  7. 42 CFR 84.91 - Breathing resistance test; exhalation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 25 mm. (1 inch) water-column height. (c) The exhalation resistance of pressure-demand apparatus shall not exceed the static pressure in the facepiece by more than 51 mm. (2 inches) water-column height. (d) The static pressure (at zero flow) in the facepiece shall not exceed 38 mm. (1.5 inches) water-column...

  8. 42 CFR 84.91 - Breathing resistance test; exhalation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 25 mm. (1 inch) water-column height. (c) The exhalation resistance of pressure-demand apparatus shall not exceed the static pressure in the facepiece by more than 51 mm. (2 inches) water-column height. (d) The static pressure (at zero flow) in the facepiece shall not exceed 38 mm. (1.5 inches) water-column...

  9. 42 CFR 84.20 - Examination, inspection, and testing of complete respirator assemblies; fees.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... assemblies; fees. Except as provided in § 84.22, the following fees shall be charged by the Institute for the examination, inspection and testing of complete respirator assemblies: Self-contained breathing apparatus... respirator assemblies; fees. 84.20 Section 84.20 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH...

  10. 42 CFR 84.20 - Examination, inspection, and testing of complete respirator assemblies; fees.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... assemblies; fees. Except as provided in § 84.22, the following fees shall be charged by the Institute for the examination, inspection and testing of complete respirator assemblies: Self-contained breathing apparatus... respirator assemblies; fees. 84.20 Section 84.20 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH...

  11. Protective Clothing

    DTIC Science & Technology

    1975-01-01

    WASHINGTON 0 C AEROSPACE TECHNOLOGY DIV HIGH -ALTITUDE PRESSURESUITS AND HERMETICALLY SEALED CABINS FOR STRATOSPHERIC FLIGHTS* (U) DESCRIPTIVE NOTE...TRANS. FROM VESTNIK VOZDUSNNOGO FLOTA, NO. So PP. 48൹, |938. DESCRIPTORS: (*PRESSURE SUITS. USSR)o PRESSURIZED CABINS. HERMETIC SEALS, HIGH ALTITUDE...STRATOSPHERE, BREATHING APPARATUS, OXYGEN EQUIPMENT, REVIEWS, DESIG(U) HIGH -ALTITUDE PRESSURE SUITS AND HERMETICALLY SEALED CABINS FOR STRATOSPHERIC

  12. 46 CFR 153.330 - Access.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS Design and Equipment Cargo Pumprooms § 153.330 Access. (a) The access door to a cargo pump-room must open on the weatheredeck. (b) The access way to a cargo pump-room and its valving must allow passage of a man wearing the breathing apparatus required by § 153...

  13. Emergency Mask OBT

    NASA Image and Video Library

    2015-07-28

    ISS044E025035 (07/29/2015) --- NASA astronaut Kjell Lindgren prepares to don protective breathing apparatus that would be used in the unlikely event of a fire or hazardous chemical leak inside the pressurized air volume of the International Space Station. Familiarization of safety and emergency equipment is standard practice for all newly arrived crew members.

  14. 42 CFR 84.20 - Examination, inspection, and testing of complete respirator assemblies; fees.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... respirator assemblies; fees. 84.20 Section 84.20 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... assemblies; fees. Except as provided in § 84.22, the following fees shall be charged by the Institute for the examination, inspection and testing of complete respirator assemblies: Self-contained breathing apparatus...

  15. 42 CFR 84.20 - Examination, inspection, and testing of complete respirator assemblies; fees.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... respirator assemblies; fees. 84.20 Section 84.20 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... assemblies; fees. Except as provided in § 84.22, the following fees shall be charged by the Institute for the examination, inspection and testing of complete respirator assemblies: Self-contained breathing apparatus...

  16. 42 CFR 84.20 - Examination, inspection, and testing of complete respirator assemblies; fees.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... respirator assemblies; fees. 84.20 Section 84.20 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH... assemblies; fees. Except as provided in § 84.22, the following fees shall be charged by the Institute for the examination, inspection and testing of complete respirator assemblies: Self-contained breathing apparatus...

  17. 29 CFR Appendix C to Subpart L of... - Fire Protection References For Further Information

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...—September 30, 1978. Evaluation and Performance of Open Circuit Breathing Apparatus. NU REG/CR-1235. Los.... § 1910.160. Fixed extinguishing systems—general information: 1. Standard for Foam Extinguishing Systems... for Hi-Expansion Foam Systems, ANSI/NFPA 11A; National Fire Protection Association, Batterymarch Park...

  18. 42 CFR Appendix - Tables to Subpart H of Part 84

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Tables to Subpart H of Part 84 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus Gas tightness test; minimum requirements. Pt. 84,...

  19. 42 CFR 84.102 - Man test 6; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...

  20. 42 CFR 84.102 - Man test 6; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...

  1. 42 CFR 84.102 - Man test 6; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...

  2. 42 CFR 84.101 - Man test 5; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.101 Man test 5; requirements. (a) Test 5 will be conducted to determine the maximum...

  3. 42 CFR 84.102 - Man test 6; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man test 6; requirements. 84.102 Section 84.102 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.102 Man test 6; requirements. (a) Man test 6 will be conducted with respect to...

  4. 42 CFR 84.101 - Man test 5; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.101 Man test 5; requirements. (a) Test 5 will be conducted to determine the maximum...

  5. 42 CFR 84.101 - Man test 5; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man test 5; requirements. 84.101 Section 84.101 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND... Breathing Apparatus § 84.101 Man test 5; requirements. (a) Test 5 will be conducted to determine the maximum...

  6. Abstracts Biomedical Research and Underwater Breathing Apparatus Evaluation Dives 10 to 1600 Feet April 1-2, 1974 Conference

    DTIC Science & Technology

    1974-04-01

    related to the Gauer-Henry reflex (atrial distension inhibiting vasopressin secretion) rather than to caloric deficiency or thermal stresses, which...syndromes, such as early muscular dystrophy, but it is also increased by hypoxia and exertion. From in vitro experiments, the increase in serum CPK appears

  7. 42 CFR 84.91 - Breathing resistance test; exhalation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 25 mm. (1 inch) water-column height. (c) The exhalation resistance of pressure-demand apparatus shall not exceed the static pressure in the facepiece by more than 51 mm. (2 inches) water-column height. (d) The static pressure (at zero flow) in the facepiece shall not exceed 38 mm. (1.5 inches) water-column...

  8. 42 CFR 84.91 - Breathing resistance test; exhalation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 25 mm. (1 inch) water-column height. (c) The exhalation resistance of pressure-demand apparatus shall not exceed the static pressure in the facepiece by more than 51 mm. (2 inches) water-column height. (d) The static pressure (at zero flow) in the facepiece shall not exceed 38 mm. (1.5 inches) water-column...

  9. Improved Oxygen Sources for Breathing Apparatus

    NASA Technical Reports Server (NTRS)

    Wood, P. C.; Wydeven, T.

    1983-01-01

    Research is described which is directed toward the preparation of chemical oxygen sources which exhibited improved O2 storage and reaction characteristics when compared to potassium superoxide (KO2). The initial focus of the research was the preparation of calcium superoxide (Ca(O2)2) by the disproportionation of calcium peroxide diperoxyhydrate. the Ca(O2)2 was characterized by chemical, thermal, and x ray analyses. Several methods for scaling up the Ca(O2)2 syntheis process were studied. The reactivity of Ca(O2)2 toward humidified carbon dioxide (CO2) was evaluated and was compared to that of KO2 under flow test conditions approximating those existing in portable breathing apparatus. The reactivities of mixtures of KO2 and Ca(O2)2 or lithium peroxide towards humidified CO2 were also studied. Finally, an analysis of two commercial, KO2-based, self contained self rescuers was conducted to determine the potential weight and volume savings which would be possible if Ca(O2)2 or a mixture of KO2 and Ca(O2)2 were used as a replacement for KO2.

  10. 29 CFR 1926.1084 - SCUBA diving.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Diving Specific Operations Procedures § 1926.1084 SCUBA diving. Note: The requirements applicable to construction work under this section are identical to those...

  11. ORAC-DR -- SCUBA Pipeline Data Reduction

    NASA Astrophysics Data System (ADS)

    Jenness, Tim; Economou, Frossie

    ORAC-DR is a flexible data reduction pipeline designed to reduce data from many different instruments. This document describes how to use the ORAC-DR pipeline to reduce data taken with the Submillimetre Common-User Bolometer Array (SCUBA) obtained from the James Clerk Maxwell Telescope.

  12. The effect of pre-dive ingestion of dark chocolate on endothelial function after a scuba dive.

    PubMed

    Theunissen, Sigrid; Balestra, Costantino; Boutros, Antoine; De Bels, David; Guerrero, François; Germonpré, Peter

    2015-03-01

    The aim of the study was to observe the effects of dark chocolate on endothelial function after scuba diving. Forty-two male scuba divers were divided into two groups: a control (n=21) and a chocolate group (n=21). They performed a 33-metres deep scuba-air dive for 20 minutes in a diving pool (Nemo 33, Brussels). Water temperature was 33⁰C. The chocolate group ingested 30 g of dark chocolate (86% cocoa) 90 minutes before the dive. Flow-mediated dilatation (FMD), digital photoplethysmography and nitric oxide (NO) and peroxynitrites (ONOO-) levels were measured before and after the scuba dive in both groups. A significant decrease in FMD was observed in the control group after the dive (91±7% (mean±95% confidence interval) of pre-dive values; P<0.001) while it was increased in the chocolate group (105±5% of pre-dive values; P<0.001). No difference in digital photoplethysmography was observed between before and after the dives. No variation of circulating NO level was observed in the control group whereas an increase was shown in the chocolate group (154±73% of pre-dive values; P=0.04). A significant reduction in ONOO- was observed in the control group (84±12% of pre-dive values; P=0.003) whereas no variation was shown after the dive with chocolate intake (100±28% of pre-dive values; ns). Ingestion of 30 g of dark chocolate 90 minutes before scuba diving prevented post-dive endothelial dysfunction, as the antioxidants contained in dark chocolate probably scavenge free radicals.

  13. Suitability Analysis For Scuba Diving To Develop Marine Tourism At Saebus Island, East Java, Indonesia

    NASA Astrophysics Data System (ADS)

    Wijaya, Putranto; Putra, Tri; Hidayat, Fatra; Levraeni, Chandra; Rizmaadi, Mada; Ambariyanto, Ambariyanto

    2018-02-01

    Indonesian government currently has policies to improve the performance of the tourism sector, including marine tourism. One of the attractions of marine tourism is the coral ecosystem especially through scuba diving activities. The purpose of this study was to determine the suitability of the coral ecosystem on Saebus Island, East Java, to find appropriate locations for scuba diving activities. Purposive samplings were done around the island to determine four stations which will be assessed through suitability analysis. Tourism Suitability Index was used to assess all stations for scuba diving activities. The result showed that all four stations were categorized as very suitable with the score: 85%, 85%, 85% and 83%, respectively. Several aspects that need to be improved and anticipated for diving at all stations are coral coverage and water current. These results suggest that there are several spots around Saebus Island that are suitable for diving site, and can be promoted as marine tourism destination.

  14. VizieR Online Data Catalog: SCUBA-2 high-redshift galaxies sample (Barger+, 2014)

    NASA Astrophysics Data System (ADS)

    Barger, A. J.; Cowie, L. L.; Chen, C.-C.; Owen, F. N.; Wang, W.-H.; Casey, C. M.; Lee, N.; Sanders, D. B.; Williams, J. P.

    2017-05-01

    We obtained 25.4 hr of observations on the CDF-N with SCUBA-2 on the JCMT during observing runs in 2012 and 2013. The data were obtained using a mixture of scanning modes and under a variety of weather conditions. Using the CV Daisy scanning mode (detailed information about the SCUBA-2 scan patterns can be found in Holland et al. 2013MNRAS.430.2513H), we obtained a 2.2 hr observation in band 1 weather (225 GHz opacity<0.05) and a 16.5 hr observation in band 2 weather (225 GHz opacity ~0.05-0.08). We also obtained a 6.7 hr observation in band 2 weather using the pong-900 scanning mode. While SCUBA-2 observes at both 450 um and 850 um simultaneously, there are too few sources directly detected at 450 um in our data to be interesting. Thus, we only use the 850 um data in our subsequent analysis. (1 data file).

  15. Managing the cryogenic systems of SCUBA-2 for long term operation

    NASA Astrophysics Data System (ADS)

    Cookson, Jamie L.; Bintley, Dan

    2016-07-01

    SCUBA-2 has been operational on JCMT producing excellent science for almost 5 years. We describe the strategy and methods that we have evolved to keep one of the world's first "dry dilution refrigerators" and the other cryogenic systems working effectively at the summit of Mauna Kea, keeping the instrument functioning at peak efficiency for extended periods (over 12 months at a time), with minimum downtime. We discuss new plans to reduce day-to-day operational costs and to add remote management of the gas handling systems, as we look to the future and envisage another ten years of SCUBA-2 science.

  16. Effect of influenza vaccination on oxidative stress products in breath.

    PubMed

    Phillips, Michael; Cataneo, Renee N; Chaturvedi, Anirudh; Danaher, Patrick J; Devadiga, Anantrai; Legendre, David A; Nail, Kim L; Schmitt, Peter; Wai, James

    2010-06-01

    Viral infections cause increased oxidative stress, so a breath test for oxidative stress biomarkers (alkanes and alkane derivatives) might provide a new tool for early diagnosis. We studied 33 normal healthy human subjects receiving scheduled treatment with live attenuated influenza vaccine (LAIV). Each subject was his or her own control, since they were studied on day 0 prior to vaccination, and then on days 2, 7 and 14 following vaccination. Breath volatile organic compounds (VOCs) were collected with a breath collection apparatus, then analyzed by automated thermal desorption with gas chromatography and mass spectroscopy. A Monte Carlo simulation technique identified non-random VOC biomarkers of infection based on their C-statistic values (area under curve of receiver operating characteristic). Treatment with LAIV was followed by non-random changes in the abundance of breath VOCs. 2, 8-Dimethyl-undecane and other alkane derivatives were observed on all days. Conservative multivariate models identified vaccinated subjects on day 2 (C-statistic = 0.82, sensitivity = 63.6% and specificity = 88.5%); day 7 (C-statistic = 0.94, sensitivity = 88.5% and specificity = 92.3%); and day 14 (C-statistic = 0.95, sensitivity = 92.3% and specificity = 92.3%). The altered breath VOCs were not detected in live attenuated influenza vaccine, excluding artifactual contamination. LAIV vaccination in healthy humans elicited a prompt and sustained increase in breath biomarkers of oxidative stress. A breath test for these VOCs could potentially identify humans who are acutely infected with influenza, but who have not yet developed clinical symptoms or signs of disease.

  17. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.100 Man tests 1...

  18. National Conference on Campus Safety (21st, University of California, Davis, June 24-28, 1974). Safety Monographs for Schools and Colleges, No. 34.

    ERIC Educational Resources Information Center

    Green, Jack N., Ed.

    Eight conference papers on miscellaneous campus safety topics are included in this conference report: "The Safe Use of Mutigens and Carcinogens in the Laboratory" by Leo K. Bustad; "Planning for Laboratory Animal Care" by Sigmund Rich; "Testing Breathing Apparatus" by Henry McDermott; "Earthquake Damage…

  19. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  20. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  1. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  2. Effects of firefighters' self-contained breathing apparatus' weight and its harness design on the physiological and subjective responses.

    PubMed

    Bakri, Ilham; Lee, Joo-Young; Nakao, Kouhei; Wakabayashi, Hitoshi; Tochihara, Yutaka

    2012-01-01

    To examine the effects of firefighters' self-contained breathing apparatus' (SCBA) weight and its harness design on the physiological and subjective responses, eight male students performed treadmill exercise under four conditions: the 8 kg firefighter protective clothing (PC) (Control), the PC + an 11 kg SCBA with an old harness (Test A), the PC + a 6.4 kg SCBA with an old harness (Test B) and the PC + a 6.4 kg SCBA with a new harness (Test C), at ambient temperatures (T(a)) of 22°C and 32°C. Besides highlighting the fact that a heavy SCBA had a significant effect on the oxygen consumption and metabolic rate, this experiment also found that in a T(a) of 32°C, in particular, the combined effect of 4.7 kg lighter SCBA and new harness design could reduce metabolic rate and improved subjective muscle fatigue and thermal discomfort. An effort to alleviate the physiological and subjective burden of firefighters by reducing the weight of SCBA and by using the new harness design has provided satisfactory results in reduced oxygen consumption and in improved subjective responses in a hot air environment.

  3. Effects of inspiratory and expiratory resistance in divers' breathing apparatus.

    PubMed

    Warkander, D E; Nagasawa, G K; Lundgren, C E

    2001-01-01

    This study was performed to determine if inspiratory breathing resistance causes greater or smaller changes than expiratory resistance. Unacceptable inspiratory resistances were also determined. Five subjects exercised at 60% of their VO2max while immersed in a hyperbaric chamber. The chamber was pressurized to either 147 kPa (1.45 atm abs, 4.5 msw, 15 fsw) or 690 kPa (6.8 atm abs, 57 msw, 190 fsw). Breathing resistance was imposed on the inspiratory or expiratory side and was as high as 0.8-1.2 kPa liter(-1) x s(-1) (8-12 cm H2O x liter(-1) x s(-1)) at a flow of 2-3 liter x s(-1) at 1 atm abs., the other side being unloaded. The subjects reacted to the imposed load by prolonging the phase of breathing that was loaded. Inspiratory breathing resistance caused greater changes than expiratory resistance in end-tidal CO2, dyspnea scores, maximum voluntary ventilation, and respiratory duty cycle. Using previously published criteria for acceptable levels of dyspnea scores and the CO2 levels, we found that an inspiratory resistance inducing a volume-averaged pressure of 1.5 kPa is not acceptable. Similarly, an expiratory resistance should not induce a volume-averaged pressure exceeding 2.0 kPa

  4. Recreational scuba diving in patients with congenital heart disease: Time for new guidelines.

    PubMed

    Schleich, Jean-Marc; Schnell, Frédéric; Brouant, Benoît; Phan, Gerald; Lafay, Vincent; Bonnemains, Laurent; Bédossa, Marc

    2016-01-01

    The number of recreational scuba divers is steadily increasing. In its latest recommendations, the French Federation of Undersea Studies and Sports listed congenital heart disease as a formal and final contraindication to scuba diving. On the other hand, with the progress made in their management, the prognosis and quality of life of patients with congenital heart diseases have improved considerably, enabling them to engage in physical and sports endeavours, which are known to confer general health and psychological benefits. As a consequence, the ability of these patients to dive has become a regular and recurrent issue. We review the various types of scuba diving, the physical performance required for its practice, its effects on cardiovascular function and the elements that need to be considered before recommending whether it can be practiced safely at various levels of difficulty. Because of the diversity and broad heterogeneity of congenital heart diseases, a detailed evaluation of each patient's performance based on clinical criteria common to all congenital heart diseases is recommended. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  5. Wide extragalactic (sub-)millimeter surveys with SCUBA and AzTEC

    NASA Astrophysics Data System (ADS)

    Aretxaga, I.; Hughes, D. H.; SHADES Collaboration; AzTEC Collaboration

    2009-05-01

    We summarize the present status of our knowledge of the millimeter galaxy population derived from extensive (sub-) millimeter extragalactic surveys like the SCUBA HAlf Degree Survey (SHADES), and the current status of the next generation of surveys traced with the AzTEC camera, that has, so far, surveyed more than 2 degrees at 1.1wavelengths.

  6. Diving into Troubled Waters: Sexual Discrimination in a Male Dominated Recreational Culture.

    ERIC Educational Resources Information Center

    Lagache, Edouard

    This paper presents results of a study of sex discrimination in the culture of scuba divers. The research grew out of class related conflicts that permitted observation in ethnographic field work, the character of gender relations in the recreational activity of scuba diving. The project was intended to investigate the role of communities of…

  7. An exploration of motivations among scuba divers in north central Florida

    Treesearch

    Louisa A. Meyer; Brijesh Thapa; Lori Pennington-Gray

    2003-01-01

    There has been a boom in the adventure travel market as 98 million adults had taken an adventure vacation between 1992 and 1997, which includes soft adventure vacations (e.g., camping, hiking, biking, bird-or-animal-watching, horseback riding, sailing, skiing), and hard adventure vacations (e.g., mountain biking, whitewater rafting/kayaking, scuba diving, rock climbing...

  8. POL-2: a polarimeter for the James-Clerk-Maxwell telescope

    NASA Astrophysics Data System (ADS)

    Friberg, Per; Bastien, Pierre; Berry, David; Savini, Giorgio; Graves, Sarah F.; Pattle, Kate

    2016-07-01

    The POL-2 polarimeter for the SCUBA-2 10 000 pixel Terahertz camera on the James Clerk Maxwell Telescope (JCMT) in it's late state of commissioning. Proposals have been accepted for POL-2 and general observing will start in August 2016. SCUBA-2 has a field of view of 43 arcmin at both of the 850 and 450 μm focal planes. POL-2 will map the sky in the the 850 μm band. The POL-2 polarimeter utilizes three optical components: a half wave plate and two wire-grid polarizers used as calibrator and analyzer covering the full field of SCUBA-2. We describe the instrument, data acquisition and features/artifacts that have been encountered during the commissioning.

  9. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set forth in Tables 1, 2, 3, and 4 of this subpart, respectively, prescribe the duration and sequence of...

  10. Moderator and Mediator Effects of Scuba Diving Specialization on Marine-Based Environmental Knowledge-Behavior Contingency

    ERIC Educational Resources Information Center

    Thapa, Brijesh; Graefe, Alan R.; Meyer, Louisa A.

    2005-01-01

    Given the growth in scuba diving activities and the importance of environmental education programs to alleviate the potential impacts on coral reef ecosystems, there is a need to better understand the diving community, its environmental knowledge, and subsequent behavioral actions. The purpose of this study was to explore the role or influence of…

  11. Scuba diving & underwater cultural resources: differences in environmental beliefs, ascriptions of responsibility, and management preferences based on level of development

    Treesearch

    Sharon L. Todd; Tiffany Cooper; Alan R. Graefe

    2001-01-01

    This study examined SCUBA divers' level of development in relationship to environmental beliefs, ascriptions of responsibility, and management preferences concerning the use and management of New York's Great Lakes' underwater cultural resources. More than 850 New York State divers were surveyed during the fall of 1999, ranging from novices to experts...

  12. Differences in SCUBA diver motivations based on level of development

    Treesearch

    Sharon L. Todd; Alan R. Graefe; Walter Mann

    2002-01-01

    This study examined SCUBA divers' level of development in relationship to their motivations to dive. During the fall of 1999,869 divers ranging from beginners to post-experts were surveyed (37% response rate). Respondents ranked 24 motives on a 5-point importance scale. When the data were reduced using factor analysis to tease out major themes, six factors (...

  13. Scuba diving accidents.

    PubMed

    Dembert, M L

    1977-08-01

    The principal scuba diving medical problems of barotrauma, air embolism and decompression sickness have as their pathophysiologic basis the Ideal Gas Law and Boyle's Law. Hyperbaric chamber recompression therapy is the only definitive treatment of air embolism and decompression sickness. However, with a basic knowledge of diving medicine, the family physician can provide effective supportive care to the patient prior to initiation of hyperbaric therapy.

  14. Commissioning of the FTS-2 Data Reduction Pipeline

    NASA Astrophysics Data System (ADS)

    Sherwood, M.; Naylor, D.; Gom, B.; Bell, G.; Friberg, P.; Bintley, D.

    2015-09-01

    FTS-2 is the intermediate resolution Fourier Transform Spectrometer coupled to the SCUBA-2 facility bolometer camera at the James Clerk Maxwell Telescope in Hawaii. Although in principle FTS instruments have the advantage of relatively simple optics compared to other spectrometers, they require more sophisticated data processing to compute spectra from the recorded interferogram signal. In the case of FTS-2, the complicated optical design required to interface with the existing telescope optics introduces performance compromises that complicate spectral and spatial calibration, and the response of the SCUBA-2 arrays introduce interferogram distortions that are a challenge for data reduction algorithms. We present an overview of the pipeline and discuss new algorithms that have been written to correct the noise introduced by unexpected behavior of the SCUBA-2 arrays.

  15. The effects of respiratory muscle training on respiratory mechanics and energy cost.

    PubMed

    Held, Heather E; Pendergast, David R

    2014-08-15

    Resistance respiratory muscle training (RRMT) increases respiratory muscle strength and can increase swimming endurance time by as much as 85%. The purpose of this study was to examine potential mechanisms by which RRMT improves exercise endurance. Eight healthy adult male scuba divers underwent experiments in a hyperbaric chamber at sea level (1 atmosphere absolute (ATA)), 2.7 ATA and 4.6 ATA, both dry and fully submersed. Subjects rested, exercised, and rested while mimicking their own exercise breathing (ISEV). Airway resistance (R(aw)), exhaled nitric oxide output (V˙(NO)), and respiratory duty cycle (T(I)/T(Tot)) were determined before and after four weeks of RRMT. RRMT decreased T(I)/T(Tot) (-10% at rest at 1 ATA), V˙(O2) (-17% at 2.7 ATA during submersed exercise), V˙(E) (-6% at 2.7 ATA during submersed exercise), and R(aw) (-34% inspiratory at 4.6 ATA submersed, -38% expiratory at 2.7 ATA dry), independent of changes in V˙(NO). Most importantly, respiratory muscle efficiency increased (+83% at 2.7 ATA submersed). Copyright © 2014 Elsevier B.V. All rights reserved.

  16. The debreather: a report on euthanasia and suicide assistance using adapted scuba technology.

    PubMed

    Ogden, Russel D

    2010-04-01

    In response to the general prohibition of euthanasia and assisted suicide, some right-to-die activists have developed non-medical methods to covertly hasten death. One such method is a "debreather," a closed system breathing device that laypersons can use to induce hypoxia for persons seeking euthanasia or assisted suicide. This article presents data from nine cases where the debreather was used on humans, resulting in eight deaths. The covert properties of the debreather make it almost impossible for medical examiners and law enforcers to detect its use. Clandestine behavior circumvents legal forms of social control and challenges models for regulated, medicalized euthanasia and assisted suicide. The debreather compromises the ability of forensic investigators to assign an accurate cause and manner of death, and this raises implications for law enforcement, vital statistics, and research into the causes of death. The involvement of lay organizations in euthanasia and assisted suicide means that effective social policy on right-to-die issues must take into account their activities as well as those of other health professionals.

  17. The preparation of calcium superoxide from calcium peroxide diperoxyhydrate

    NASA Technical Reports Server (NTRS)

    Ballou, E. V.; Wood, P. C.; Spitze, L. A.; Wydeven, T.

    1977-01-01

    There is interest in solid materials containing a high percentage of stored oxygen for use in emergency breathing apparatus for miners and as auxiliary oxygen sources for astronauts. In theory, the amount of available oxygen in calcium superoxide, Ca(O2)2 is higher than in potassium superoxide, KO2, and its availability during use should be unhindered by the formation of a low melting and hydrous coating. The decomposition of solid calcium peroxide diperoxyhydrate, CaO2.2H2O2 has been studied, using an apparatus which allows good control of the critical reaction parameters. Samples have been prepared showing apparent superoxide contents in excess of those previously reported and higher than the theoretical 58.4% expected from a disproportionation reaction.

  18. International Conference on Environmental Ergonomics (4th) Held in Austin, Texas on 1-5 October 1990

    DTIC Science & Technology

    1991-01-15

    measurement error in relation 94 Ducharme, Michel B. to clothing and tissue insulation -- a simplified view 5 Reischl, Uwe Breathability measurements...PROTECTIVE CLOTHING Uwe Reischl, Francis N. Dukes-Dobos, Thomas E. Bernard and Kai Buller Department of Environmental and Occupational Health 0 College of...understood. 117 BREATHING APPARATUS AND VENTILATION William P. Morgan Biodynamics Laboratory University of Wisconsin- Madison 0 Madison , Wisconsin USA

  19. Explosive Ordnance Disposal (EOD) Ensembles: Biophysical Characteristics and Predicted Work Times With and Without Chemical Protection and Active Cooling Systems

    DTIC Science & Technology

    2015-04-29

    socks), white cotton glove liners , butyl rubber overboots, and self-contained breathing apparatus (SCBA) with air tank. Configuration 3: EOD suit...0073492 SCBA, CBRN, HP 60 Min Carbon DB, ZST, Case, VAS CON - CF Harness and Tank N/A 4240-20-A0F4879 Cylinder , Air Carbon HP 60 Minute - CF N/A 8120-20-007-3487 19

  20. Air Revitalization Using Superoxides

    NASA Technical Reports Server (NTRS)

    Wydeven, Theodore; Wood, Peter C.; Spitze, L. A.

    1988-01-01

    Pellets made from powder mixtures of potassium superoxide, KO2, and calcium superoxide, Ca(O2)2, proven markedly superior to pellets of pure KO2 for adding O2 to and removing CO2 from atmospheric-pressure flow of humidified CO2 in He. Superoxides used extensively to supply O2 and scrub CO2 in variety of ambient-pressure life-support applications, including portable self-contained breathing apparatuses, spacecraft, and undersea submersible craft.

  1. Defense Contract Management Agency Santa Ana Quality Assurance Oversight Needs lmprovement

    DTIC Science & Technology

    2013-04-19

    Management Agency Santa Ana Quality Assurance Oversight Needs Improvement What We Did We determined whether the Defense Contract Management Agency (DCMA...for critical safety items (CSIs). For this audit, we reviewed QA oversight of four contracts valued at about $278 million. What We Found The DCMA...limited assurance that 18,507 critical safety items, consisting of T-11 parachutes, oxygen masks, drone parachutes, and breathing apparatuses met

  2. Uterine Contraction Modeling and Simulation

    NASA Technical Reports Server (NTRS)

    Liu, Miao; Belfore, Lee A.; Shen, Yuzhong; Scerbo, Mark W.

    2010-01-01

    Building a training system for medical personnel to properly interpret fetal heart rate tracing requires developing accurate models that can relate various signal patterns to certain pathologies. In addition to modeling the fetal heart rate signal itself, the change of uterine pressure that bears strong relation to fetal heart rate and provides indications of maternal and fetal status should also be considered. In this work, we have developed a group of parametric models to simulate uterine contractions during labor and delivery. Through analysis of real patient records, we propose to model uterine contraction signals by three major components: regular contractions, impulsive noise caused by fetal movements, and low amplitude noise invoked by maternal breathing and measuring apparatus. The regular contractions are modeled by an asymmetric generalized Gaussian function and least squares estimation is used to compute the parameter values of the asymmetric generalized Gaussian function based on uterine contractions of real patients. Regular contractions are detected based on thresholding and derivative analysis of uterine contractions. Impulsive noise caused by fetal movements and low amplitude noise by maternal breathing and measuring apparatus are modeled by rational polynomial functions and Perlin noise, respectively. Experiment results show the synthesized uterine contractions can mimic the real uterine contractions realistically, demonstrating the effectiveness of the proposed algorithm.

  3. Impact of SCBA size and fatigue from different firefighting work cycles on firefighter gait.

    PubMed

    Kesler, Richard M; Bradley, Faith F; Deetjen, Grace S; Angelini, Michael J; Petrucci, Matthew N; Rosengren, Karl S; Horn, Gavin P; Hsiao-Wecksler, Elizabeth T

    2018-04-04

    Risk of slips, trips and falls in firefighters maybe influenced by the firefighter's equipment and duration of firefighting. This study examined the impact of a four self-contained breathing apparatus (SCBA) three SCBA of increasing size and a prototype design and three work cycles one bout (1B), two bouts with a five-minute break (2B) and two bouts back-to-back (BB) on gait in 30 firefighters. Five gait parameters (double support time, single support time, stride length, step width and stride velocity) were examined pre- and post-firefighting activity. The two largest SCBA resulted in longer double support times relative to the smallest SCBA. Multiple bouts of firefighting activity resulted in increased single and double support time and decreased stride length, step width and stride velocity. These results suggest that with larger SCBA or longer durations of activity, firefighters may adopt more conservative gait patterns to minimise fall risk. Practitioner Summary: The effects of four self-contained breathing apparatus (SCBA) and three work cycles on five gait parameters were examined pre- and post-firefighting activity. Both SCBA size and work cycle affected gait. The two largest SCBA resulted in longer double support times. Multiple bouts of activity resulted in more conservative gait patterns.

  4. The SCUBA-2 Cosmology Legacy Survey: Multiwavelength Counterparts to 103 Submillimeter Galaxies in the UKIDSS-UDS Field

    NASA Astrophysics Data System (ADS)

    Chen, Chian-Chou; Smail, Ian; Ivison, Rob J.; Arumugam, Vinodiran; Almaini, Omar; Conselice, Christopher J.; Geach, James E.; Hartley, Will G.; Ma, Cheng-Jiun; Mortlock, Alice; Simpson, Chris; Simpson, James M.; Swinbank, A. Mark; Aretxaga, Itziar; Blain, Andrew; Chapman, Scott C.; Dunlop, James S.; Farrah, Duncan; Halpern, Mark; Michałowski, Michał J.; van der Werf, Paul; Wilkinson, Aaron; Zavala, Jorge A.

    2016-04-01

    We present multiwavelength identifications for the counterparts of 1088 submillimeter sources detected at 850 μm in the SCUBA-2 Cosmology Legacy Survey study of the UKIRT Infrared Deep Sky Survey-Ultra-Deep Survey (UDS) field. By utilizing an Atacama Large Millimeter Array (ALMA) pilot study on a subset of our bright SCUBA-2 sample as a training set, along with the deep optical-near-infrared (OIR) data available in this field, we develop a novel technique, Optical-IR Triple Color (OIRTC), using z - K, K - [3.6], [3.6] - [4.5] colors to select the candidate submillimeter galaxy (SMG) counterparts. By combining radio identification and the OIRTC technique, we find counterpart candidates for 80% of the Class = 1 ≥ 4σ SCUBA-2 sample, defined as those that are covered by both radio and OIR imaging and the base sample for our scientific analyses. Based on the ALMA training set, we expect the accuracy of these identifications to be 82% ± 20%, with a completeness of 69% ± 16%, essentially as accurate as the traditional p-value technique but with higher completeness. We find that the fraction of SCUBA-2 sources having candidate counterparts is lower for fainter 850 μm sources, and we argue that for follow-up observations sensitive to SMGs with S850 ≳ 1 mJy across the whole ALMA beam, the fraction with multiple counterparts is likely to be >40% for SCUBA-2 sources at S850 ≳ 4 mJy. We find that the photometric redshift distribution for the SMGs is well fit by a lognormal distribution, with a median redshift of z = 2.3 ± 0.1. After accounting for the sources without any radio and/or OIRTC counterpart, we estimate the median redshift to be z = 2.6 ± 0.1 for SMGs with S850 > 1 mJy. We also use this new large sample to study the clustering of SMGs and the far-infrared properties of the unidentified submillimeter sources by stacking their Herschel SPIRE far-infrared emission.

  5. Do reef fish habituate to diver presence? Evidence from two reef sites with contrasting historical levels of SCUBA intensity in the Bay Islands, Honduras.

    PubMed

    Titus, Benjamin M; Daly, Marymegan; Exton, Dan A

    2015-01-01

    Contact between humans and the marine environment is increasing, but the capacity of communities to adapt to human presence remains largely unknown. The popularization of SCUBA diving has added a new dimension to human impacts in aquatic systems and, although individual-level impacts have been identified, cumulative effects on ecosystem function and community-wide responses are unclear. In principle, habituation may mitigate the consequences of human presence on the biology of an individual and allow the quick resumption of its ecological roles, but this has not been documented in aquatic systems. Here, we investigate the short-term impact of human presence and the long-term habituation potential of reef-fish communities to recreational SCUBA divers by studying symbiotic cleaning interactions on coral reefs with differing levels of historical contact with divers. We show that incidences of human contact result in a smaller decline in ecosystem function and more rapid resumption of baseline services on a reef in Utila, Honduras that has heavy historical levels of SCUBA diver presence, compared to an un-dived reef site in the Cayos Cochinos Marine Protected Area (CCMPA). Nonetheless, despite the generally smaller change in ecosystem function and decades of regular contact with divers, cleaning behavior is suppressed by >50% at Utila when divers are present. We hypothesize that community-wide habituation of reef fish is not fully achievable and may be biologically restricted to only partial habituation. Differential responses to human presence impacts the interpretation and execution of behavioral research where SCUBA is the predominant means of data collection, and provides an important rationale for future research investigating the interplay between human presence, ecosystem function, and community structure on coral reefs.

  6. Development and maintenance of force and stiffness in airway smooth muscle.

    PubMed

    Lan, Bo; Norris, Brandon A; Liu, Jeffrey C-Y; Paré, Peter D; Seow, Chun Y; Deng, Linhong

    2015-03-01

    Airway smooth muscle (ASM) plays a central role in the excessive narrowing of the airway that characterizes the primary functional impairment in asthma. This phenomenon is known as airway hyper-responsiveness (AHR). Emerging evidence suggests that the development and maintenance of ASM force involves dynamic reorganization of the subcellular filament network in both the cytoskeleton and the contractile apparatus. In this review, evidence is presented to support the view that regulation of ASM contraction extends beyond the classical actomyosin interaction and involves processes within the cytoskeleton and at the interfaces between the cytoskeleton, the contractile apparatus, and the extracellular matrix. These processes are initiated when the muscle is activated, and collectively they cause the cytoskeleton and the contractile apparatus to undergo structural transformation, resulting in a more connected and solid state that allows force generated by the contractile apparatus to be transmitted to the extracellular domain. Solidification of the cytoskeleton also serves to stiffen the muscle and hence the airway. Oscillatory strain from tidal breathing and deep inspiration is believed to be the counter balance that prevents hypercontraction and stiffening of ASM in vivo. Dysregulation of this balance could lead to AHR seen in asthma.

  7. VizieR Online Data Catalog: JCMT Gould Belt Survey: W40 complex (Rumble+, 2016)

    NASA Astrophysics Data System (ADS)

    Rumble, D.; Hatchell, J.; Pattle, K.; Kirk, H.; Wilson, T.; Buckle, J.; Berry, D. S.; Broekhoven-Fiene, H.; Currie, M. J.; Fich, M.; Jenness, T.; Johnstone, D.; Mottram, J. C.; Nutter, D.; Pineda, J. E.; Quinn, C.; Salji, C.; Tisi, S.; Walker-Smith, S.; di, Francesco J.; Hogerheijde, M. R.; Ward-Thompson, D.; Bastien, P.; Bresnahan, D.; Butner, H.; Chen, M.; Chrysostomou, A.; Coude, S.; Davis, C. J.; Drabek-Maunder, E.; Duarte-Cabral, A.; Fiege, J.; Friberg, P.; Friesen, R.; Fuller, G. A.; Graves, S.; Greaves, J.; Gregson, J.; Holland, W.; Joncas, G.; Kirk, J. M.; Knee, L. B. G.; Mairs, S.; Marsh, K.; Matthews, B. C.; Moriarty-Schieven, G.; Mowat, C.; Rawlings, J.; Richer, J.; Robertson, D.; Rosolowsky, E.; Sadavoy, S.; Thomas, H.; Tothill, N.; Viti, S.; White, G. J.; Wouterloot, J.; Yates, J.; Zhu, M.

    2017-11-01

    Aquila was observed with SCUBA-2 (Holland et al., 2013MNRAS.430.2513H) between 2012 April 21 and July 5 as part of the JCMT GBS MJLSG33 SCUBA-2 Serpens Campaign. Four separate fully sampled 30 arcmin diameter circular continuum observations (PONG1800 mapping mode) were taken simultaneously at 850um and 450um, and subsequently combined into mosaics. (3 data files).

  8. VizieR Online Data Catalog: Properties of SCUBA cores in Perseus mol. cloud (Curtis+, 2010)

    NASA Astrophysics Data System (ADS)

    Curtis, E. I.; Richer, J. S.

    2013-05-01

    We extracted fully calibrated and reduced SCUBA 850um maps across the four regions in Perseus we observed with HARP from the data presented by Hatchell et al. (2005, Cat. J/A+A/440/151), where we refer the reader for details of the observations and processing. In short, the data were taken during 20 nights between 1999 and 2003. (2 data files).

  9. SCUBA-2 follow-up of Herschel-SPIRE observed Planck overdensities

    NASA Astrophysics Data System (ADS)

    MacKenzie, Todd P.; Scott, Douglas; Bianconi, Matteo; Clements, David L.; Dole, Herve A.; Flores-Cacho, Inés; Guery, David; Kneissl, Ruediger; Lagache, Guilaine; Marleau, Francine R.; Montier, Ludovic; Nesvadba, Nicole P. H.; Pointecouteau, Etienne; Soucail, Genevieve

    2017-07-01

    We present SCUBA-2 follow-up of 61 candidate high-redshift Planck sources. Of these, 10 are confirmed strong gravitational lenses and comprise some of the brightest such submm sources on the observed sky, while 51 are candidate proto-cluster fields undergoing massive starburst events. With the accompanying Herschel-Spectral and Photometric Imaging Receiver observations and assuming an empirical dust temperature prior of 34^{+13}_{-9} K, we provide photometric redshift and far-IR luminosity estimates for 172 SCUBA-2-selected sources within these Planck overdensity fields. The redshift distribution of the sources peak between a redshift of 2 and 4, with one-third of the sources having S500/S350 > 1. For the majority of the sources, we find far-IR luminosities of approximately 1013 L⊙, corresponding to star formation rates of around 1000 M⊙ yr-1. For S850 > 8 mJy sources, we show that there is up to an order of magnitude increase in star formation rate density and an increase in uncorrected number counts of 6 for S850 > 8 mJy when compared to typical cosmological survey fields. The sources detected with SCUBA-2 account for only approximately 5 per cent of the Planck flux at 353 GHz, and thus many more fainter sources are expected in these fields.

  10. Noninvasive measurement of mean alveolar carbon dioxide tension and Bohr's dead space during tidal breathing.

    PubMed

    Koulouris, N G; Latsi, P; Dimitroulis, J; Jordanoglou, B; Gaga, M; Jordanoglou, J

    2001-06-01

    The lack of methodology for measuring the alveolar carbon dioxide tension (PA,CO2) has forced investigators to make several assumptions, such as that PA,CO2 is equal to end-tidal (PET,CO2) and arterial CO2 tension (Pa,CO2). The present study measured the mean PA,CO2 and Bohr's dead space ratio (Bohr's dead space/tidal volume (VD,Bohr/VT)) during tidal breathing. The method used is a new, simple and noninvasive technique, based on the analysis of the expired CO2 volume per breath (VCO2) versus the exhaled VT. This curve was analysed in 21 normal, healthy subjects and 35 chronic obstructive pulmonary disease (COPD) patients breathing tidally through a mouthpiece apparatus in the sitting position. It is shown that: 1) PA,CO2 is similar to Pa,CO2 in normal subjects, whilst it is significantly lower than Pa,CO2 in COPD patients; 2) PA,CO2 is significantly higher than PET,CO2 in all subjects, especially in COPD patients; 3) VD,Bohr/VT is increased in COPD patients as compared to normal subjects; and 4) VD,Bohr/VT is lower than the "physiological" dead space ratio (VD,phys/VT) in COPD patients. It is concluded that the expired carbon dioxide versus tidal volume curve is a useful tool for research and clinical work, because it permits the noninvasive and accurate measurement of Bohr's dead space and mean alveolar carbon dioxide tension accurately during spontaneous breathing.

  11. [Is scuba diving allowed in diabetic patients treated with insulin?].

    PubMed

    Dufaitre, L; Vialettes, B

    2000-11-01

    Scuba diving is usually prohibited in diabetic patients at risk of hypoglycemic attacks (i.e. IDDM and NIDDM treated with sulfonylureas) due to the particular severity of these episodes in a hostile environment. In fact, diabetic subjects can perform this popular leisure activity without extra-risk, provided strict requisites in aptitude, practice and environment are enforced. These limitations lead to the establishment of practical guidelines, as proposed in this paper.

  12. THE SCUBA-2 COSMOLOGY LEGACY SURVEY: MULTIWAVELENGTH COUNTERPARTS TO 10{sup 3} SUBMILLIMETER GALAXIES IN THE UKIDSS-UDS FIELD

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Chian-Chou; Smail, Ian; Ma, Cheng-Jiun

    We present multiwavelength identifications for the counterparts of 1088 submillimeter sources detected at 850 μm in the SCUBA-2 Cosmology Legacy Survey study of the UKIRT Infrared Deep Sky Survey-Ultra-Deep Survey (UDS) field. By utilizing an Atacama Large Millimeter Array (ALMA) pilot study on a subset of our bright SCUBA-2 sample as a training set, along with the deep optical–near-infrared (OIR) data available in this field, we develop a novel technique, Optical–IR Triple Color (OIRTC), using z − K, K − [3.6], [3.6] − [4.5] colors to select the candidate submillimeter galaxy (SMG) counterparts. By combining radio identification and the OIRTC technique, we find counterpart candidates formore » 80% of the Class = 1 ≥ 4σ SCUBA-2 sample, defined as those that are covered by both radio and OIR imaging and the base sample for our scientific analyses. Based on the ALMA training set, we expect the accuracy of these identifications to be 82% ± 20%, with a completeness of 69% ± 16%, essentially as accurate as the traditional p-value technique but with higher completeness. We find that the fraction of SCUBA-2 sources having candidate counterparts is lower for fainter 850 μm sources, and we argue that for follow-up observations sensitive to SMGs with S{sub 850} ≳ 1 mJy across the whole ALMA beam, the fraction with multiple counterparts is likely to be >40% for SCUBA-2 sources at S{sub 850} ≳ 4 mJy. We find that the photometric redshift distribution for the SMGs is well fit by a lognormal distribution, with a median redshift of z = 2.3 ± 0.1. After accounting for the sources without any radio and/or OIRTC counterpart, we estimate the median redshift to be z = 2.6 ± 0.1 for SMGs with S{sub 850} > 1 mJy. We also use this new large sample to study the clustering of SMGs and the far-infrared properties of the unidentified submillimeter sources by stacking their Herschel SPIRE far-infrared emission.« less

  13. The History and Implications of Design Standards for Underwater Breathing Apparatus - 1954 to 2015

    DTIC Science & Technology

    2015-02-11

    respiratory loading using both simple models of fluid mechanics and experimental evidence. An understanding of the influence of both respiratory ventilatory... fluid dynamics of flow in divers’ airways. It allows testing laboratories to make maximum use of all of their testing data, and lo present that data in...tireless efforts of numerous military divers at Navy Experimental Diving Unit in Panama City, FL and Naval Medical Research Institute, Bethesda, MD

  14. FY 2000/FY 2001 Budget Estimates, Air National Guard, FY 2000 Military Construction Program, Justification Data Submitted to Congress.

    DTIC Science & Technology

    1999-02-01

    299 28 271 0 194 16 178 0 TOTAL OFFICER ENLISTED 948 120 828 954 89 865 12. RESERVE UNIT DATA UNIT DESIGNATION 156 Aircraft Generation...with oil/water separator, fire suppression (overhead wet pipe and underwing AFFF ), personnel breathing apparatus, fall protection system, and all...underwing AFFF ), and floor refmishing/restriping. The hangar shops and offices require relocation/renovation. Various utility systems need to be

  15. Application of a mass spectrometer as a capnograph

    NASA Astrophysics Data System (ADS)

    Elokhin, V. A.; Ershov, T. D.; Levshankov, A. I.; Nikolaev, V. I.; Elizarov, A. Yu.

    2010-12-01

    The feasibility of using a mass spectrometer for monitoring the carbon dioxide and inhalational anesthetic concentrations in the breathing circuit of an apparatus for inhalational anesthesia are demonstrated. Mass-spectrometric data for the CO2 and inhalational anesthetic concentrations are compared with related optical data. The advantages of the mass spectrometer as a capnograph over the optical spectrometer are indicated. The variation of the inhalational anesthetic content in expired air is shown to depend on the muscle relaxation efficiency.

  16. Technology for the cities

    NASA Technical Reports Server (NTRS)

    1971-01-01

    The activities of an organization for making the technology derived from NASA programs available for use by urban communities are discussed. Examples of technology utilization accomplished by the organization are: (1) self-contained breathing apparatus for firemen, (2) short range communication systems, (3) pavement marking, (4) protective clothing for firemen, (5) underground pipe and conduit locator, and (6) automatic fire hose flow regulator. The manner in which urban problems are identified and the designation of applicable technical developments are described.

  17. Scuba Weights

    NASA Technical Reports Server (NTRS)

    1995-01-01

    The Attitude Adjuster is a system for weight repositioning corresponding to a SCUBA diver's changing positions. Compact tubes on the diver's air tank permit controlled movement of lead balls within the Adjuster, automatically repositioning when the diver changes position. Manufactured by Think Tank Technologies, the system is light and small, reducing drag and energy requirements and contributing to lower air consumption. The Mid-Continent Technology Transfer Center helped the company with both technical and business information and arranged for the testing at Marshall Space Flight Center's Weightlessness Environmental Training Facility for astronauts.

  18. Hardware and Procedures for Using the Diveair2 Monitor to Test Diving Air Quality in the Field

    DTIC Science & Technology

    2011-09-01

    Dive System ( LWDS ), and the Fly- Away Dive System (FADS); b. one pressure-reducing regulator (“reducer”) mounted on the inside of the lid of the...1. compressors and air banks, 6 2. scuba bottles that had already been charged, 3. the Navy’s LWDS , both during and after charging, and...site where the charging whip attaches to that scuba bottle. c. A LWDS adaptor, to allow air from the LWDS to be sampled both during and after

  19. Wisconsin's study of manned Mars missions

    NASA Technical Reports Server (NTRS)

    1987-01-01

    The design group focused on three topics: (1) Extravehicular Activities, (2) Sample Return Missions, and (3) Structural and Construction Considerations of a Manned Mars Habitat. Extravehicular Activities permit a Mars based astronaut to exit the habitat and perform mission activities in the harsh Mars environment. Today's spacesuit gloves are bulky, hard to manipulate and fatiguing. A mechanical assistance mechanism has been developed for the glove that will reduce user fatigue and increase the duration of EVA's. Oxygen supply systems are also being developed for the EVA astronaut. A scuba type system of tanked breathing air proves to be the most efficient system for short duration EVA's. A system that extracts the oxygen from atmospheric carbon dioxide can provide oxygen for long duration FVA's. Sample Return Missions require that samples be taken from several sites. Transportation considerations are addressed and two transportation schemes are proposed. The first scheme involves a lighter than air balloon. This system provides excellent range. The second design is a rover that uses tracks rather than wheels. Track rovers perform well in soft, sandy conditions. Engineering aspects of a habitat and domed greenhouse were investigated and plans for the habitat have been made. A configuration has been established and construction details have been made.

  20. Compact Eucapnic Voluntary Hyperpnoea Apparatus for Exercise-Induced Respiratory Disease Detection

    PubMed Central

    Wang, Lulu; Al-Jumaily, Ahmed

    2017-01-01

    Eucapnic voluntary hyperpnoea (EVH) challenge provides objective criteria for exercise-induced asthma (EIA) or exercise-induced bronchoconstriction (EIB), and it was recommended to justify the use of inhaled β2-agonists by athletes for the Olympics. This paper presents the development of a compact and easy-to-use EVH apparatus for assessing EIB in human subjects. The compact apparatus has been validated on human subjects and the results have been compared to the conventional EVH system. Twenty-two swimmers, including eleven healthy subjects and eleven subjects who had been physician-diagnosed with asthma, were recruited from sport and recreation centers throughout Auckland, New Zealand. Each subject performed two EVH challenge tests using the proposed breathing apparatus and the conventional Phillips EVH apparatus on separate days, respectively. Forced expiratory volume in one second (FEV1) was measured before and after the challenges. A reduction in FEV1 of 10% or more was considered positive. Of the eleven subjects who were previously diagnosed with asthma, EIB was present in all subjects (100%) in the compact EVH group, while it was presented in ten subjects (90.91%) in the conventional EVH challenge group. Of the eleven healthy subjects, EIB was present in one subject (4.55%) in the compact EVH group, while it was not present in the conventional EVH group. Experimental results showed that the compact EVH system has potential to become an alternative tool for EIB detection. PMID:28509868

  1. Detailed Analysis and Design Review of the MARK IX (Modified) Underwater Breathing Apparatus

    DTIC Science & Technology

    1969-07-30

    hard- chrome plated, and the purge-valve assembly and regulator piston . electroless-nickel plated. Manufacturing/Assembly Controls and Tests The control...high a flow through the orifice, peak pressures of 4500 psi have been applied repeatedly with- out failure or damage to any component. (7) Orifice...c) Proved In use. (d) "Functional" test by stpplkir. (5)J (e) Peak pressure of only 4500 jsi reached. (1) (f) Leak test at 1-1/2 •is. (g) Predive

  2. Cylindrical acoustic levitator/concentrator

    DOEpatents

    Kaduchak, Gregory; Sinha, Dipen N.

    2002-01-01

    A low-power, inexpensive acoustic apparatus for levitation and/or concentration of aerosols and small liquid/solid samples having particulates up to several millimeters in diameter in air or other fluids is described. It is constructed from a commercially available, hollow cylindrical piezoelectric crystal which has been modified to tune the resonance frequency of the breathing mode resonance of the crystal to that of the interior cavity of the cylinder. When the resonance frequency of the interior cylindrical cavity is matched to the breathing mode resonance of the cylindrical piezoelectric transducer, the acoustic efficiency for establishing a standing wave pattern in the cavity is high. The cylinder does not require accurate alignment of a resonant cavity. Water droplets having diameters greater than 1 mm have been levitated against the force of gravity using; less than 1 W of input electrical power. Concentration of aerosol particles in air is also demonstrated.

  3. Anesthesia equipment malfunction: origins and clinical recognition.

    PubMed Central

    McIntyre, J. W.

    1979-01-01

    Equipment malfunction is a problem of particular importance during anesthesia and resuscitation. A review of published reports shows that the most common clinical events involve endotracheal tubes, the inspired oxygen concentration, the volume of inspired anesthetic vapours and gases, and pressures in the breathing or ventilation system. It is concluded that protection of a patient from equipment malfunction depends on: (a) appropriate application of standards set by a national standards association; (b) careful evaluation of equipment prior to purchase; (c) comprehension of equipment function by the user; (d) conscientious routine servicing of all systems concerned with anesthesia and resuscitation, and checking after service and before clinical use; (e) preanesthesia testing of equipment, including the use of an oxygen analyser in the breathing circuit; (f) early inclusion of equipment malfunction in the differential diagnosis of events during anesthesia; and (g) rapid action that cannot present a new hazard to the patient to correct the results of apparatus malfunction. PMID:436069

  4. Bluetooth Communication Interface for EEG Signal Recording in Hyperbaric Chambers.

    PubMed

    Pastena, Lucio; Formaggio, Emanuela; Faralli, Fabio; Melucci, Massimo; Rossi, Marco; Gagliardi, Riccardo; Ricciardi, Lucio; Storti, Silvia F

    2015-07-01

    Recording biological signals inside a hyperbaric chamber poses technical challenges (the steel walls enclosing it greatly attenuate or completely block the signals as in a Faraday cage), practical (lengthy cables creating eddy currents), and safety (sparks hazard from power supply to the electronic apparatus inside the chamber) which can be overcome with new wireless technologies. In this technical report we present the design and implementation of a Bluetooth system for electroencephalographic (EEG) recording inside a hyperbaric chamber and describe the feasibility of EEG signal transmission outside the chamber. Differently from older systems, this technology allows the online recording of amplified signals, without interference from eddy currents. In an application of this technology, we measured EEG activity in professional divers under three experimental conditions in a hyperbaric chamber to determine how oxygen, assumed at a constant hyperbaric pressure of 2.8 ATA , affects the bioelectrical activity. The EEG spectral power estimated by fast Fourier transform and the cortical sources of the EEG rhythms estimated by low-resolution brain electromagnetic analysis were analyzed in three different EEG acquisitions: breathing air at sea level; breathing oxygen at a simulated depth of 18 msw, and breathing air at sea level after decompression.

  5. Automated Reduction and Calibration of SCUBA Archive Data Using ORAC-DR

    NASA Astrophysics Data System (ADS)

    Jenness, T.; Stevens, J. A.; Archibald, E. N.; Economou, F.; Jessop, N.; Robson, E. I.; Tilanus, R. P. J.; Holland, W. S.

    The Submillimetre Common User Bolometer Array (SCUBA) instrument has been operating on the James Clerk Maxwell Telescope (JCMT) since 1997. The data archive is now sufficiently large that it can be used for investigating instrumental properties and the variability of astronomical sources. This paper describes the automated calibration and reduction scheme used to process the archive data with particular emphasis on the pointing observations. This is made possible by using the ORAC-DR data reduction pipeline, a flexible and extensible data reduction pipeline that is used on UKIRT and the JCMT.

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, W.; Korea Basic Science Institute; Stepanyan, S. S.

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping ismore » used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the {sup 3}He-N{sub 2} mixture. The cells could be refilled. The {sup 3}He reaches around 50% polarization in 5-15 hours.« less

  7. Optical Pumping Spin Exchange 3He Gas Cells for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Kim, W.; Stepanyan, S. S.; Kim, A.; Jung, Y.; Woo, S.; Yurov, M.; Jang, J.

    2009-08-01

    We present a device for spin-exchange optical pumping system to produce large quantities of polarized noble gases for Magnetic Resonance Imaging (MRI). A method and design of apparatus for pumping the polarization of noble gases is described. The method and apparatus enable production, storage and usage of hyperpolarized noble gases for different purposes, including Magnetic Resonance Imaging of human and animal subjects. Magnetic imaging agents breathed into lungs can be observed by the radio waves of the MRI scanner and report back physical and functional information about lung's health and desease. The technique known as spin exchange optical pumping is used. Nuclear magnetic resonance is implemented to measure the polarization of hyperpolarized gas. The cells prepared and sealed under high vacuum after handling Alkali metals into the cell and filling with the 3He-N2 mixture. The cells could be refilled. The 3He reaches around 50% polarization in 5-15 hours.

  8. [Truth curves on soot blackened paper--apparatus-supported lie detection in Graz in the 1920s].

    PubMed

    Bachhiesl, Christian

    2014-01-01

    In the 1920s, experiments with apparatus-supported lie detection and registration of expression were conducted at the Criminological Institute of the University of Graz in order to establish a sound methodological basis for testimony research. For this purpose, the criminologist Ernst Seelig used a method of lie detection developed by the psychologist Vittorio Benussi, which focuses on the analysis of breathing. Benussi had stated that the expiration after telling a lie was faster than after telling the truth, but Seelig could not verify this rule in forensic practice. Consequently, this method of lie detection was of no practical use for criminology. Seelig also carried out experiments with the method of registration of expression developed by the psychiatrist Otto Lowenstein. He registered the examinee's thoracic and abdominal breathing and the movements of the extremities with the help of a kymograph. By interpretation of the curves recorded on soot blackened paper, conclusions concerning the mental elements of an offence as well as the existence of certain dispositions and of amnesia should have been made possible. Seelig was convinced of the efficiency of this method. These experiments can be regarded as early attempts at finding not only simple facts but also answers to quasi-metaphysical questions concerning the "true nature" of man with the help of methods based on natural science and modern technology. Thus they are precursors of present-day neuroscience and neuro-imaging.

  9. Exploratory breath analyses for assessing toxic dermal exposures of firefighters during suppression of structural burns.

    PubMed

    Pleil, Joachim D; Stiegel, Matthew A; Fent, Kenneth W

    2014-09-01

    Firefighters wear fireproof clothing and self-contained breathing apparatus (SCBA) during rescue and fire suppression activities to protect against acute effects from heat and toxic chemicals. Fire services are also concerned about long-term health outcomes from chemical exposures over a working lifetime, in particular about low-level exposures that might serve as initiating events for adverse outcome pathways (AOP) leading to cancer. As part of a larger US National Institute for Occupational Safety and Health (NIOSH) study of dermal exposure protection from safety gear used by the City of Chicago firefighters, we collected pre- and post-fire fighting breath samples and analyzed for single-ring and polycyclic aromatic hydrocarbons as bioindicators of occupational exposure to gas-phase toxicants. Under the assumption that SCBA protects completely against inhalation exposures, any changes in the exhaled profile of combustion products were attributed to dermal exposures from gas and particle penetration through the protective clothing. Two separate rounds of firefighting activity were performed each with 15 firefighters per round. Exhaled breath samples were collected onto adsorbent tubes and analyzed with gas-chromatography-mass spectrometry (GC-MS) with a targeted approach using selective ion monitoring. We found that single ring aromatics and some PAHs were statistically elevated in post-firefighting samples of some individuals, suggesting that fire protective gear may allow for dermal exposures to airborne contaminants. However, in comparison to a previous occupational study of Air Force maintenance personnel where similar compounds were measured, these exposures are much lower suggesting that firefighters' gear is very effective. This study suggests that exhaled breath sampling and analysis for specific targeted compounds is a suitable method for assessing systemic dermal exposure in a simple and non-invasive manner.

  10. A Non-Invasive Method for Estimating Cardiopulmonary Variables Using Breath-by-Breath Injection of Two Tracer Gases.

    PubMed

    Clifton, Lei; Clifton, David A; Hahn, Clive E W; Farmeryy, Andrew D

    2013-01-01

    Conventional methods for estimating cardiopulmonary variables usually require complex gas analyzers and the active co-operation of the patient. Therefore, they are not compatible with the crowded environment of the intensive care unit (ICU) or operating theatre, where patient co-operation is typically impossible. However, it is these patients that would benefit the most from accurate estimation of cardiopulmonary variables, because of their critical condition. This paper describes the results of a collaborative development between an anesthesiologists and biomedical engineers to create a compact and non-invasive system for the measurement of cardiopulmonary variables such as lung volume, airway dead space volume, and pulmonary blood flow. In contrast with conventional methods, the compact apparatus and non-invasive nature of the proposed method allow it to be used in the ICU, as well as in general clinical settings. We propose the use of a non-invasive method, in which tracer gases are injected into the patient's inspired breath, and the concentration of the tracer gases is subsequently measured. A novel breath-by-breath tidal ventilation model is then used to estimate the value of a patient's cardiopulmonary variables. Experimental results from an artificial lung demonstrate minimal error in the estimation of known parameters using the proposed method. Results from analysis of a cohort of 20 healthy volunteers (within the Oxford University Hospitals NHS Trust) show that the values of estimated cardiopulmonary variables from these subjects lies within the expected ranges. Advantages of this method are that it is non-invasive, compact, portable, and can perform analysis in real time with less than 1 min of acquired respiratory data.

  11. Mobility, expansion and management of a multi-species scuba diving fishery in East Africa.

    PubMed

    Eriksson, Hampus; de la Torre-Castro, Maricela; Olsson, Per

    2012-01-01

    Scuba diving fishing, predominantly targeting sea cucumbers, has been documented to occur in an uncontrolled manner in the Western Indian Ocean and in other tropical regions. Although this type of fishing generally indicates a destructive activity, little attention has been directed towards this category of fishery, a major knowledge gap and barrier to management. With the aim to capture geographic scales, fishing processes and social aspects the scuba diving fishery that operate out of Zanzibar was studied using interviews, discussions, participant observations and catch monitoring. The diving fishery was resilient to resource declines and had expanded to new species, new depths and new fishing grounds, sometimes operating approximately 250 km away from Zanzibar at depths down to 50 meters, as a result of depleted easy-access stock. The diving operations were embedded in a regional and global trade network, and its actors operated in a roving manner on multiple spatial levels, taking advantage of unfair patron-client relationships and of the insufficient management in Zanzibar. This study illustrates that roving dynamics in fisheries, which have been predominantly addressed on a global scale, also take place at a considerably smaller spatial scale. Importantly, while proposed management of the sea cucumber fishery is often generic to a simplified fishery situation, this study illustrates a multifaceted fishery with diverse management requirements. The documented spatial scales and processes in the scuba diving fishery emphasize the need for increased regional governance partnerships to implement management that fit the spatial scales and processes of the operation.

  12. Diving down the reefs? Intensive diving tourism threatens the reefs of the northern Red Sea.

    PubMed

    Hasler, Harald; Ott, Jörg A

    2008-10-01

    Intensive recreational SCUBA diving threatens coral reef ecosystems. The reefs at Dahab, South Sinai, Egypt, are among the world's most dived (>30,000 dives y(-1)). We compared frequently dived sites to sites with no or little diving. Benthic communities and condition of corals were examined by the point intercept sampling method in the reef crest zone (3m) and reef slope zone (12 m). Additionally, the abundance of corallivorous and herbivorous fish was estimated based on the visual census method. Sediments traps recorded the sedimentation rates caused by SCUBA divers. Zones subject to intensive SCUBA diving showed a significantly higher number of broken and damaged corals and significantly lower coral cover. Reef crest coral communities were significantly more affected than those of the reef slope: 95% of the broken colonies were branching ones. No effect of diving on the abundance of corallivorous and herbivorous fish was evident. At heavily used dive sites, diver-related sedimentation rates significantly decreased with increasing distance from the entrance, indicating poor buoyancy regulation at the initial phase of the dive. The results show a high negative impact of current SCUBA diving intensities on coral communities and coral condition. Corallivorous and herbivorous fishes are apparently not yet affected, but are endangered if coral cover decline continues. Reducing the number of dives per year, ecologically sustainable dive plans for individual sites, and reinforcing the environmental education of both dive guides and recreational divers are essential to conserve the ecological and the aesthetic qualities of these dive sites.

  13. Mobility, Expansion and Management of a Multi-Species Scuba Diving Fishery in East Africa

    PubMed Central

    Eriksson, Hampus; de la Torre-Castro, Maricela; Olsson, Per

    2012-01-01

    Background Scuba diving fishing, predominantly targeting sea cucumbers, has been documented to occur in an uncontrolled manner in the Western Indian Ocean and in other tropical regions. Although this type of fishing generally indicates a destructive activity, little attention has been directed towards this category of fishery, a major knowledge gap and barrier to management. Methodology and Principal Findings With the aim to capture geographic scales, fishing processes and social aspects the scuba diving fishery that operate out of Zanzibar was studied using interviews, discussions, participant observations and catch monitoring. The diving fishery was resilient to resource declines and had expanded to new species, new depths and new fishing grounds, sometimes operating approximately 250 km away from Zanzibar at depths down to 50 meters, as a result of depleted easy-access stock. The diving operations were embedded in a regional and global trade network, and its actors operated in a roving manner on multiple spatial levels, taking advantage of unfair patron-client relationships and of the insufficient management in Zanzibar. Conclusions and Significance This study illustrates that roving dynamics in fisheries, which have been predominantly addressed on a global scale, also take place at a considerably smaller spatial scale. Importantly, while proposed management of the sea cucumber fishery is often generic to a simplified fishery situation, this study illustrates a multifaceted fishery with diverse management requirements. The documented spatial scales and processes in the scuba diving fishery emphasize the need for increased regional governance partnerships to implement management that fit the spatial scales and processes of the operation. PMID:22530034

  14. Funding conservation through use and potentials for price discrimination among scuba divers at Sipadan, Malaysia.

    PubMed

    Emang, Diana; Lundhede, Thomas Hedemark; Thorsen, Bo Jellesmark

    2016-11-01

    The protected coral reefs off the coast of Malaysia receive numerous tourists, while also being as fishing grounds. These joint environmental pressures raise the need for additional costly conservation measures. It is natural to consider the potential for expanding the 'user pays' principle, already implemented in the form of various user fees. This study explores the potential for price discrimination among scuba divers at Sipadan in Malaysia. The study applies a choice experiment to estimate scuba divers willingness to pay higher user fees for avoiding decreases of or getting improvements in environmental and recreational aspects of the diving experience. We investigate how sensitivity to fee size and hence willingness to pay vary with suitable selected characteristics of divers. We find potentials for a third degree price discrimination strategy exploiting higher willingness to pay among foreign divers (45%), male divers (16%) and people who has visited Sipadan several times (25%). Thus, revised pricing structures could significantly increase funds for the preservation of Sipadan. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Space Suit Technologies Protect Deep-Sea Divers

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Working on NASA missions allows engineers and scientists to hone their skills. Creating devices for the high-stress rigors of space travel pushes designers to their limits, and the results often far exceed the original concepts. The technologies developed for the extreme environment of space are often applicable here on Earth. Some of these NASA technologies, for example, have been applied to the breathing apparatuses worn by firefighters, the fire-resistant suits worn by racecar crews, and, most recently, the deep-sea gear worn by U.S. Navy divers.

  16. The preparation of calcium superoxide at subambient temperatures and pressures. [oxygen source for breathing apparatus

    NASA Technical Reports Server (NTRS)

    Ballou, E. V.; Wood, P. C.; Spitze, L. A.; Wydeven, T.; Stein, R.

    1977-01-01

    The effects of disproportionations at lower temperatures and also of a range of reaction chamber pressures on the preparation of calcium superoxide, Ca(O2)2, from calcium peroxide diperoxyhydrate were studied. About 60% purity of product was obtained by a disproportionation procedure. The significance of features of this procedure for a prospective scale-up of the mass prepared in a single experiment is considered. The optimum pressure for product purity was determined, and the use of a molecular sieve desiccant is described.

  17. Bringing space technology down to earth

    NASA Technical Reports Server (NTRS)

    Gray, E. Z.

    1974-01-01

    The direct transfer of space technology to terrestial applications is demonstrated by the use of fuel cells to augment existing electric power-generation facilities. The role of NASA's Technology Utilization Program is discussed in regard to indirect transfer of technology. The Tech Brief program for identifying and reporting innovations, the regional dissemination centers, and the Applications Teams working with other government agencies and the medical community are described. Projects discussed include the development of a lightweight breathing apparatus for firemen, a practical method for separating nonferrous metals from automobile scrap, and a rechargeable heart pacemaker.

  18. DIME Students Participate in SCUBA Lesson Spring 2002

    NASA Technical Reports Server (NTRS)

    2002-01-01

    In addition to drop tower activities, students assembled a plastic pipe structure underwater in a SCUBA exercise similar to training astronauts receive at NASA Johnson Space Center. This was part of the second Dropping in a Microgravity Environment (DIME) competition held April 23-25, 2002, at NASA's Glenn Research Center. Competitors included two teams from Sycamore High School, Cincinnati, OH, and one each from Bay High School, Bay Village, OH, and COSI Academy, Columbus, OH. DIME is part of NASA's education and outreach activities. Details are on line at http://microgravity.grc.nasa.gov/DIME_2002.html.

  19. Respiratory evolution facilitated the origin of pterosaur flight and aerial gigantism.

    PubMed

    Claessens, Leon P A M; O'Connor, Patrick M; Unwin, David M

    2009-01-01

    Pterosaurs, enigmatic extinct Mesozoic reptiles, were the first vertebrates to achieve true flapping flight. Various lines of evidence provide strong support for highly efficient wing design, control, and flight capabilities. However, little is known of the pulmonary system that powered flight in pterosaurs. We investigated the structure and function of the pterosaurian breathing apparatus through a broad scale comparative study of respiratory structure and function in living and extinct archosaurs, using computer-assisted tomographic (CT) scanning of pterosaur and bird skeletal remains, cineradiographic (X-ray film) studies of the skeletal breathing pump in extant birds and alligators, and study of skeletal structure in historic fossil specimens. In this report we present various lines of skeletal evidence that indicate that pterosaurs had a highly effective flow-through respiratory system, capable of sustaining powered flight, predating the appearance of an analogous breathing system in birds by approximately seventy million years. Convergent evolution of gigantism in several Cretaceous pterosaur lineages was made possible through body density reduction by expansion of the pulmonary air sac system throughout the trunk and the distal limb girdle skeleton, highlighting the importance of respiratory adaptations in pterosaur evolution, and the dramatic effect of the release of physical constraints on morphological diversification and evolutionary radiation.

  20. Respiratory Evolution Facilitated the Origin of Pterosaur Flight and Aerial Gigantism

    PubMed Central

    Claessens, Leon P. A. M.; O'Connor, Patrick M.; Unwin, David M.

    2009-01-01

    Pterosaurs, enigmatic extinct Mesozoic reptiles, were the first vertebrates to achieve true flapping flight. Various lines of evidence provide strong support for highly efficient wing design, control, and flight capabilities. However, little is known of the pulmonary system that powered flight in pterosaurs. We investigated the structure and function of the pterosaurian breathing apparatus through a broad scale comparative study of respiratory structure and function in living and extinct archosaurs, using computer-assisted tomographic (CT) scanning of pterosaur and bird skeletal remains, cineradiographic (X-ray film) studies of the skeletal breathing pump in extant birds and alligators, and study of skeletal structure in historic fossil specimens. In this report we present various lines of skeletal evidence that indicate that pterosaurs had a highly effective flow-through respiratory system, capable of sustaining powered flight, predating the appearance of an analogous breathing system in birds by approximately seventy million years. Convergent evolution of gigantism in several Cretaceous pterosaur lineages was made possible through body density reduction by expansion of the pulmonary air sac system throughout the trunk and the distal limb girdle skeleton, highlighting the importance of respiratory adaptations in pterosaur evolution, and the dramatic effect of the release of physical constraints on morphological diversification and evolutionary radiation. PMID:19223979

  1. The SCUBA-2 Ambitious Sky Survey: a catalogue of beam-sized sources in the Galactic longitude range 120°-140°

    NASA Astrophysics Data System (ADS)

    Nettke, Will; Scott, Douglas; Gibb, Andy G.; Thompson, Mark; Chrysostomou, Antonio; Evans, A.; Hill, Tracey; Jenness, Tim; Joncas, Gilles; Moore, Toby; Serjeant, Stephen; Urquhart, James; Vaccari, Mattia; Weferling, Bernd; White, Glenn; Zhu, Ming

    2017-06-01

    The SCUBA-2 Ambitious Sky Survey (SASSy) is composed of shallow 850-μm imaging using the Submillimetre Common-User Bolometer Array 2 (SCUBA-2) on the James Clerk Maxwell Telescope. Here we describe the extraction of a catalogue of beam-sized sources from a roughly 120 deg2 region of the Galactic plane mapped uniformly (to an rms level of about 40 mJy), covering longitude 120° < l < 140° and latitude |b| < 2.9°. We used a matched-filtering approach to increase the signal-to-noise ratio (S/N) in these noisy maps and tested the efficiency of our extraction procedure through estimates of the false discovery rate, as well as by adding artificial sources to the real images. The primary catalogue contains a total of 189 sources at 850 μm, down to an S/N threshold of approximately 4.6. Additionally, we list 136 sources detected down to S/N = 4.3, but recognize that as we go lower in S/N, the reliability of the catalogue rapidly diminishes. We perform follow-up observations of some of our lower significance sources through small targeted SCUBA-2 images and list 265 sources detected in these maps down to S/N = 5. This illustrates the real power of SASSy: inspecting the shallow maps for regions of 850-μm emission and then using deeper targeted images to efficiently find fainter sources. We also perform a comparison of the SASSy sources with the Planck Catalogue of Compact Sources and the IRAS Point Source Catalogue, to determine which sources discovered in this field might be new, and hence potentially cold regions at an early stage of star formation.

  2. The Herschel Bright Sources (HerBS): sample definition and SCUBA-2 observations

    NASA Astrophysics Data System (ADS)

    Bakx, Tom J. L. C.; Eales, S. A.; Negrello, M.; Smith, M. W. L.; Valiante, E.; Holland, W. S.; Baes, M.; Bourne, N.; Clements, D. L.; Dannerbauer, H.; De Zotti, G.; Dunne, L.; Dye, S.; Furlanetto, C.; Ivison, R. J.; Maddox, S.; Marchetti, L.; Michałowski, M. J.; Omont, A.; Oteo, I.; Wardlow, J. L.; van der Werf, P.; Yang, C.

    2018-01-01

    We present the Herschel Bright Sources (HerBS) sample, a sample of bright, high-redshift Herschel sources detected in the 616.4 deg2 Herschel Astrophysical Terahertz Large Area Survey. The HerBS sample contains 209 galaxies, selected with a 500 μm flux density greater than 80 mJy and an estimated redshift greater than 2. The sample consists of a combination of hyperluminous infrared galaxies and lensed ultraluminous infrared galaxies during the epoch of peak cosmic star formation. In this paper, we present Submillimetre Common-User Bolometer Array 2 (SCUBA-2) observations at 850 μm of 189 galaxies of the HerBS sample, 152 of these sources were detected. We fit a spectral template to the Herschel-Spectral and Photometric Imaging Receiver (SPIRE) and 850 μm SCUBA-2 flux densities of 22 sources with spectroscopically determined redshifts, using a two-component modified blackbody spectrum as a template. We find a cold- and hot-dust temperature of 21.29_{-1.66}^{+1.35} and 45.80_{-3.48}^{+2.88} K, a cold-to-hot dust mass ratio of 26.62_{-6.74}^{+5.61} and a β of 1.83_{-0.28}^{+0.14}. The poor quality of the fit suggests that the sample of galaxies is too diverse to be explained by our simple model. Comparison of our sample to a galaxy evolution model indicates that the fraction of lenses are high. Out of the 152 SCUBA-2 detected galaxies, the model predicts 128.4 ± 2.1 of those galaxies to be lensed (84.5 per cent). The SPIRE 500 μm flux suggests that out of all 209 HerBS sources, we expect 158.1 ± 1.7 lensed sources, giving a total lensing fraction of 76 per cent.

  3. A case-control study evaluating relative risk factors for decompression sickness: a research report.

    PubMed

    Suzuki, Naoko; Yagishita, Kazuyosi; Togawa, Seiichiro; Okazaki, Fumihiro; Shibayama, Masaharu; Yamamoto, Kazuo; Mano, Yoshihiro

    2014-01-01

    Factors contributing to the pathogenesis of decompression sickness (DCS) in divers have been described in many studies. However, relative importance of these factors has not been reported. In this case-control study, we compared the diving profiles of divers experiencing DCS with those of a control group. The DCS group comprised 35 recreational scuba divers who were diagnosed by physicians as having DCS. The control group consisted of 324 apparently healthy recreational divers. All divers conducted their dives from 2009 to 2011. The questionnaire consisted of 33 items about an individual's diving profile, physical condition and activities before, during and just after the dive. To simplify dive parameters, the dive site was limited to Izu Osezaki. Odds ratios and multiple logistic regression were used for the analysis. Odds ratios revealed several items as dive and health factors associated with DCS. The major items were as follows: shortness of breath after heavy exercise during the dive (OR = 12.12), dehydration (OR = 10.63), and maximum dive depth > 30 msw (OR = 7.18). Results of logistic regression were similar to those by odds ratio analysis. We assessed the relative weights of the surveyed dive and health factors associated with DCS. Because results of several factors conflict with previous studies, future studies are needed.

  4. Cylindrical acoustic levitator/concentrator having non-circular cross-section

    DOEpatents

    Kaduchak, Gregory; Sinha, Dipen N.

    2003-11-11

    A low-power, inexpensive acoustic apparatus for levitation and/or concentration of aerosols and small liquid/solid samples having particulates up to several millimeters in diameter in air or other fluids is described. It is constructed from a commercially available, hollow piezoelectric crystal which has been formed with a cylindrical cross-section to tune the resonance frequency of the breathing mode resonance of the crystal to that of the interior cavity of the cylinder. When the resonance frequency of the interior cylindrical cavity is matched to the breathing mode resonance of the cylindrical piezoelectric transducer, the acoustic efficiency for establishing a standing wave pattern in the cavity is high. By deforming the circular cross-section of the transducer, the acoustic force is concentrated along axial regions parallel to the axis of the transducer. The cylinder does not require accurate alignment of a resonant cavity. The concentrated regions of acoustic force cause particles in the fluid to concentrate within the regions of acoustic force for separation from the fluid.

  5. Cardiovascular health effects following exposure of human volunteers during fire extinction exercises.

    PubMed

    Andersen, Maria Helena Guerra; Saber, Anne Thoustrup; Pedersen, Peter Bøgh; Loft, Steffen; Hansen, Åse Marie; Koponen, Ismo Kalevi; Pedersen, Julie Elbæk; Ebbehøj, Niels; Nørskov, Eva-Carina; Clausen, Per Axel; Garde, Anne Helene; Vogel, Ulla; Møller, Peter

    2017-09-06

    Firefighters have increased risk of cardiovascular disease and of sudden death from coronary heart disease on duty while suppressing fires. This study investigated the effect of firefighting activities, using appropriate personal protective equipment (PPE), on biomarkers of cardiovascular effects in young conscripts training to become firefighters. Healthy conscripts (n = 43) who participated in a rescue educational course for firefighting were enrolled in the study. The exposure period consisted of a three-day training course where the conscripts participated in various firefighting exercises in a constructed firehouse and flashover container. The subjects were instructed to extinguish fires of either wood or wood with electrical cords and mattresses. The exposure to particulate matter (PM) was assessed at various locations and personal exposure was assessed by portable PM samplers and urinary excretion of 1-hydroxypyrene. Cardiovascular measurements included microvascular function and heart rate variability (HRV). The subjects were primarily exposed to PM in bystander positions, whereas self-contained breathing apparatus effectively abolished pulmonary exposure. Firefighting training was associated with elevated urinary excretion of 1-hydroxypyrene (105%, 95% CI: 52; 157%), increased body temperature, decreased microvascular function (-18%, 95% CI: -26; -9%) and altered HRV. There was no difference in cardiovascular measurements for the two types of fires. Observations from this fire extinction training show that PM exposure mainly occurs in situations where firefighters removed the self-contained breathing apparatus. Altered cardiovascular disease endpoints after the firefighting exercise period were most likely due to complex effects from PM exposure, physical exhaustion and increased core body temperature.

  6. Absolute vs. Weight-Related Maximum Oxygen Uptake in Firefighters: Fitness Evaluation with and without Protective Clothing and Self-Contained Breathing Apparatus among Age Group

    PubMed Central

    Perroni, Fabrizio; Guidetti, Laura; Cignitti, Lamberto; Baldari, Carlo

    2015-01-01

    During fire emergencies, firefighters wear personal protective devices (PC) and a self-contained breathing apparatus (S.C.B.A.) to be protected from injuries. The purpose of this study was to investigate the differences of aerobic level in 197 firefighters (age: 34±7 yr; BMI: 24.4±2.3 kg.m-2), evaluated by a Queen’s College Step field Test (QCST), performed with and without fire protective garments, and to analyze the differences among age groups (<25 yr; 26-30 yr, 31-35 yr, 36-40 yr and >40 yr). Variance analysis was applied to assess differences (p < 0.05) between tests and age groups observed in absolute and weight-related values, while a correlation was examined between QCST with and without PC+S.C.B.A. The results have shown that a 13% of firefighters failed to complete the test with PC+S.C.B.A. and significant differences between QCST performed with and without PC+S.C.B.A. in absolute (F(1,169) = 42.6, p < 0.0001) and weight-related (F(1,169) = 339.9, p < 0.0001) terms. A better correlation has been found in L•min-1 (r=0.67) than in ml•kg-1•min-1 (r=0.54). Moreover, we found significant differences among age groups both in absolute and weight-related values. The assessment of maximum oxygen uptake of firefighters in absolute term can be a useful tool to evaluate the firefighters' cardiovascular strain. PMID:25764201

  7. Herschel and SCUBA-2 observations of dust emission in a sample of Planck cold clumps

    NASA Astrophysics Data System (ADS)

    Juvela, Mika; He, Jinhua; Pattle, Katherine; Liu, Tie; Bendo, George; Eden, David J.; Fehér, Orsolya; Michel, Fich; Fuller, Gary; Hirano, Naomi; Kim, Kee-Tae; Li, Di; Liu, Sheng-Yuan; Malinen, Johanna; Marshall, Douglas J.; Paradis, Deborah; Parsons, Harriet; Pelkonen, Veli-Matti; Rawlings, Mark G.; Ristorcelli, Isabelle; Samal, Manash R.; Tatematsu, Ken'ichi; Thompson, Mark; Traficante, Alessio; Wang, Ke; Ward-Thompson, Derek; Wu, Yuefang; Yi, Hee-Weon; Yoo, Hyunju

    2018-04-01

    Context. Analysis of all-sky Planck submillimetre observations and the IRAS 100 μm data has led to the detection of a population of Galactic cold clumps. The clumps can be used to study star formation and dust properties in a wide range of Galactic environments. Aims: Our aim is to measure dust spectral energy distribution (SED) variations as a function of the spatial scale and the wavelength. Methods: We examined the SEDs at large scales using IRAS, Planck, and Herschel data. At smaller scales, we compared JCMT/SCUBA-2 850 μm maps with Herschel data that were filtered using the SCUBA-2 pipeline. Clumps were extracted using the Fellwalker method, and their spectra were modelled as modified blackbody functions. Results: According to IRAS and Planck data, most fields have dust colour temperatures TC 14-18 K and opacity spectral index values of β = 1.5-1.9. The clumps and cores identified in SCUBA-2 maps have T 13 K and similar β values. There are some indications of the dust emission spectrum becoming flatter at wavelengths longer than 500 μm. In fits involving Planck data, the significance is limited by the uncertainty of the corrections for CO line contamination. The fits to the SPIRE data give a median β value that is slightly above 1.8. In the joint SPIRE and SCUBA-2 850 μm fits, the value decreases to β 1.6. Most of the observed T-β anticorrelation can be explained by noise. Conclusions: The typical submillimetre opacity spectral index β of cold clumps is found to be 1.7. This is above the values of diffuse clouds, but lower than in some previous studies of dense clumps. There is only tentative evidence of a T-β anticorrelation and β decreasing at millimetre wavelengths. Planck (http://www.esa.int/Planck) is a project of the European Space Agency - ESA - with instruments provided by two scientific consortia funded by ESA member states (in particular the lead countries: France and Italy) with contributions from NASA (USA), and telescope reflectors provided in a collaboration between ESA and a scientific consortium led and funded by Denmark.Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.

  8. 21st Century Skin Findings Response.

    PubMed

    Reese, V; Croley, J A; Ryan, M P; Wagner, R F

    2018-04-28

    We read of interest the letter by Ishida et al, "Skin Findings of 21 st Century Movie Characters." 1 The authors conclude that the prevalence of movie villains with cutaneous lesions in cinema since 2000 is lower than films released in the 20 th century. Reviewing their examples, we note some frank errors in the data presented. Immortan Joe from "Mad Max: Fury Road" is listed as having a "lip deficit." This is due to trauma and under his breathing apparatus, there is marked scarring. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  9. Metabolism: The Physiological Power-Generating Process: A History of Methods to Test Human Beings' \\"Vital Capacity\\" [Retrospectroscope].

    PubMed

    Johnston, Richard; Valentinuzzi, Max E

    2016-01-01

    A previous "Retrospectroscope" note, published early in 2014, dealt with spirometry: it described many apparatuses used to measure the volume of inhaled and exhaled air that results from breathing [1]. Such machines, when adequately modified, are also able to measure the rate at which work is produced (specifically by an animal or a human being). Metabolism in that sense is the term used by physiologists and physicians, a word that in Greek, metabolismos, means "change" or "overthrow," in the sense of breaking down material, as in burning some stuff.

  10. KSC-2013-2696

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - A small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, is on display at BCS Life Support in Titusville, Fla. The CryoBA and a larger Cryogenic Refuge Alternative Supply System, or CryoRASS, are being developed by a NASA Kennedy Space Center engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  11. KSC-2013-2700

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - The Cryogenic Refuge Alternative Supply System, or CryoRASS, is on display at BCS Life Support in Titusville, Fla. CryoRASS and a small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, are being developed by a NASA Kennedy Space Center engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  12. KSC-2013-2694

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - The Cryogenic Refuge Alternative Supply System, or CryoRASS, and a smaller liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, are on display at BCS Life Support in Titusville, Fla. The two systems are being developed by a NASA Kennedy Space Center engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  13. KSC-2013-2695

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - A small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, is on display at BCS Life Support in Titusville, Fla. The CryoBA and a larger Cryogenic Refuge Alternative Supply System, or CryoRASS, are being developed by a NASA Kennedy Space Center engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  14. Laboratory verification respiratory measurements. IMBLMS phase B.4, appendix C, section 13

    NASA Technical Reports Server (NTRS)

    1970-01-01

    The B-4 IMBLMS preliminary design of the respiratory measurement element includes certain techniques and apparatus which are quite different from those included in the B-3 version previously delivered to NASA-MSC. A working model was constructed in the laboratory to prove the feasibility of certain key features. The most critical of these is the capability of switching sample gases into the mass spectrometer from two different sources during a single breath cycle. Results proved the feasibility of all of the concepts which were tested, and certain refinements and improvements were included, as well.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Martin, Audrey Noreen

    Homeland security relies heavily on analytical chemistry to identify suspicious materials and persons. Traditionally this role has focused on attribution, determining the type and origin of an explosive, for example. But as technology advances, analytical chemistry can and will play an important role in the prevention and preemption of terrorist attacks. More sensitive and selective detection techniques can allow suspicious materials and persons to be identified even before a final destructive product is made. The work presented herein focuses on the use of commercial and novel detection techniques for application to the prevention of terrorist activities. Although drugs are notmore » commonly thought of when discussing terrorism, narcoterrorism has become a significant threat in the 21st century. The role of the drug trade in the funding of terrorist groups is prevalent; thus, reducing the trafficking of illegal drugs can play a role in the prevention of terrorism by cutting off much needed funding. To do so, sensitive, specific, and robust analytical equipment is needed to quickly identify a suspected drug sample no matter what matrix it is in. Single Particle Aerosol Mass Spectrometry (SPAMS) is a novel technique that has previously been applied to biological and chemical detection. The current work applies SPAMS to drug analysis, identifying the active ingredients in single component, multi-component, and multi-tablet drug samples in a relatively non-destructive manner. In order to do so, a sampling apparatus was created to allow particle generation from drug tablets with on-line introduction to the SPAMS instrument. Rules trees were developed to automate the identification of drug samples on a single particle basis. A novel analytical scheme was also developed to identify suspect individuals based on chemical signatures in human breath. Human breath was sampled using an RTube{trademark} and the trace volatile organic compounds (VOCs) were preconcentrated using solid phase microextraction (SPME) and identified using gas chromatography - mass spectrometry (GC-MS). Modifications to the sampling apparatus allowed for increased VOC collection efficiency, and reduced the time of sampling and analysis by over 25%. The VOCs are present in breath due to either endogenous production, or exposure to an external source through absorption, inhalation, or ingestion. Detection of these exogenous chemicals can provide information on the prior location and activities of the subject. Breath samples collected before and after exposure in a hardware store and nail salon were analyzed to investigate the prior location of a subject; breath samples collected before and after oral exposure to terpenes and terpenoid compounds, pseudoephedrine, and inhalation exposure to hexamine and other explosive related compounds were analyzed to investigate the prior activity of a subject. The elimination of such compounds from the body was also monitored. In application, this technique may provide an early warning system to identify persons of interest in the prevention and preemption stages of homeland security.« less

  16. Phase diagram and breathing dynamics of a single red blood cell and a biconcave capsule in dilute shear flow.

    PubMed

    Yazdani, Alireza Z K; Bagchi, Prosenjit

    2011-08-01

    We present phase diagrams of the single red blood cell and biconcave capsule dynamics in dilute suspension using three-dimensional numerical simulations. The computational geometry replicates an in vitro linear shear flow apparatus. Our model includes all essential properties of the cell membrane, namely, the resistance against shear deformation, area dilatation, and bending, as well as the viscosity difference between the cell interior and suspending fluids. By considering a wide range of shear rate and interior-to-exterior fluid viscosity ratio, it is shown that the cell dynamics is often more complex than the well-known tank-treading, tumbling, and swinging motion and is characterized by an extreme variation of the cell shape. As a result, it is often difficult to clearly establish whether the cell is swinging or tumbling. Identifying such complex shape dynamics, termed here as "breathing" dynamics, is the focus of this article. During the breathing motion at moderate bending rigidity, the cell either completely aligns with the flow direction and the membrane folds inward, forming two cusps, or it undergoes large swinging motion while deep, craterlike dimples periodically emerge and disappear. At lower bending rigidity, the breathing motion occurs over a wider range of shear rates, and is often characterized by the emergence of a quad-concave shape. The effect of the breathing dynamics on the tank-treading-to-tumbling transition is illustrated by detailed phase diagrams which appear to be more complex and richer than those of vesicles. In a remarkable departure from the vesicle dynamics, and from the classical theory of nondeformable cells, we find that there exists a critical viscosity ratio below which the transition is independent of the viscosity ratio, and dependent on shear rate only. Further, unlike the reduced-order models, the present simulations do not predict any intermittent dynamics of the red blood cells.

  17. VizieR Online Data Catalog: JCMT Gould Belt Survey: dense cores in Orion B (Kirk+, 2016)

    NASA Astrophysics Data System (ADS)

    Kirk, H.; Di Francesco, J.; Johnstone, D.; Duarte-Cabral, A.; Sadavoy, S.; Hatchell, J.; Mottram, J. C.; Buckle, J.; Berry, D. S.; Broekhoven-Fiene, H.; Currie, M. J.; Fich, M.; Jenness, T.; Nutter, D.; Pattle, K.; Pineda, J. E.; Quinn, C.; Salji, C.; Tisi, S.; Hogerheijde, M. R.; Ward-Thompson, D.; Bastien, P.; Bresnahan, D.; Butner, H.; Chen, M.; Chrysostomou, A.; Coude, S.; Davis, C. J.; Drabek-Maunder, E.; Fiege, J.; Friberg, P.; Friesen, R.; Fuller, G. A.; Graves, S.; Greaves, J.; Gregson, J.; Holland, W.; Joncas, G.; Kirk, J. M.; Knee, L. B. G.; Mairs, S.; Marsh, K.; Matthews, B. C.; Moriarty-Schieven, G.; Mowat, C.; Rawlings, J.; Richer, J.; Robertson, D.; Rosolowsky, E.; Rumble, D.; Thomas, H.; Tothill, N.; Viti, S.; White, G. J.; Wouterloot, J.; Yates, J.; Zhu, M.

    2016-04-01

    Orion B was observed with SCUBA-2 at 850 and 450um as part of the JCMT Gould Belt Survey (Ward-Thompson et al. 2007PASP..119..855W). Three separate regions were observed: the areas around L1622, NGC 2023/2024, and NGC 2068/2071, as illustrated in Figure 1. The SCUBA-2 observations were obtained between 2012 February and 2014 November with some initial science verification data taken in 2011 October and November. Portions of the NGC 2023/2024 and NGC 2068/2071 regions were also observed by the Gould Belt Survey (GBS) in 12CO(3-2) with HARP. (1 data file).

  18. The Dusty Galactic Center as Seen by SCUBA-2

    NASA Astrophysics Data System (ADS)

    Parsons, H.; Dempsey, J. T.; Thomas, H. S.; Berry, D.; Currie, M. J.; Friberg, P.; Wouterloot, J. G. A.; Chrysostomou, A.; Graves, S.; Tilanus, R. P. J.; Bell, G. S.; Rawlings, M. G.

    2018-02-01

    We present new JCMT SCUBA-2 observations of the Galactic Center region from 355^\\circ < l< 5^\\circ and b< +/- 1^\\circ , covering 10 × 2 square degrees along the Galactic Plane to a depth of 43 mJy beam‑1 at 850 μm and 360 mJy beam‑1 at 450 μm. We describe the mapping strategy and reduction method used. We present 12CO(3-2) observations of selected regions in the field. We derive the molecular-line conversion factors (mJy beam‑1 per K km s‑1) at 850 and 450 μm, which are then used to obtain the amount of contamination in the continuum maps due to 12CO(3-2) emission in the 850 μm band. Toward the fields where the CO contamination has been accounted for, we present an 850 μm CO-corrected compact source catalog. Finally, we look for possible physical trends in the CO contamination with respect to column density, mass, and concentration. No trends were seen in the data despite the recognition of three contributors to CO contamination: opacity, shocks, and temperature, which would be expected to relate to physical conditions. These SCUBA-2 Galactic Center data and catalog are available via https://doi.org/10.11570/17.0009.

  19. Energetics of the Ventilatory Piston Pump of the Lugworm, a Deposit-feeding Polychaete Living in a Burrow.

    PubMed

    Toulmond, A; Dejours, P

    1994-04-01

    The aim of this study was to tentatively estimate the energy cost of breathing in the lugworm, Arenicola marina (L.), a gallery-dwelling, piston-pump breather that moves water in a tail-to-head direction. Each tested lugworm was placed in a horizontal glass tube. The caudal end of the tube was connected to a well-aerated seawater reservoir at 20{deg}C, and the cephalic end attached to a drop meter through a tube resistance. At the exit of the cephalic chamber the O2 tension was recorded via an in situ O2 electrode, and the hydrostatic pressure of the exhaled water was also recorded. Water flow rate, total O2 uptake rate {Mdot}TOTO2, O2 extraction coefficient, and the mechanical power necessary to pump water through the resistive anterior exit of the apparatus ({Wdot}MEC), were computed. The basal metabolic rate of each animal ({Mdot}CONFO2) was separately estimated by the confinement method. {Mdot}CONFO2 subtracted from {Mdot}TOTO2 approximates {Mdot}CBO2, the O2 uptake rate necessary to activate the piston-pump breathing mechanism and to ensure the corresponding mechanical work rate, {Wdot}MEC. The results show that the energy cost of breathing, {Mdot}CBO2, of the piston-pump-breathing Arenicola is very high, with mean values approximating 47% of the {Mdot}TOTO2 value; that the mechanical power we measured, {Wdot}MEC, is very low; and that the mechanical-to-metabolic efficiency, the ratio {Wdot}MEC/{Mdot}CBO2, does not exceed 1%. These observations are compared to those obtained in other piston-pump breathers, such as Chaetopterus variopedatus and Urechis caupo, and in ciliary filter feeders including polychaetes, bivalves, and ascidians.

  20. Evaluation of the mineralization degree of the vestibular surface of the upper central incisors with a 655-nm diode laser in mouth breathers: preliminary results

    NASA Astrophysics Data System (ADS)

    Pinheiro Ladalardo, Thereza C. C. G.; Cappellette, Mario, Jr.; Zanin, Fatima A. A.; Brugnera, Aldo, Jr.; Anthero de Azevedo, Ramiro; Pignatari, Shirley; Weckx, Luc L. M.

    2003-06-01

    Mouth breathing unbalances the physiological mechanisms of the dental surface hydration by compromising lip closure, and, very often, causing the vestibular positioning of upper incisors. That variance leads to the interruption of the dental demineralization and remineralization feedback, prevailing a demineralized condition of the dental surface which increases caries risk. The laser fluorescence examination allows an early demineralization diagnosis, thus it makes possible through preventive measures to minimize the risk factor - dental mineral structure loss - in the bacterial infection of the demineralized area, and hence, preventing invasive therapeutical procedures. A DIAGNOdent apparatus was used to evaluate the mineralization degree of the upper central incisors in 40 patients - twenty of them with a mouth breathing diagnosis; the remaining twenty were nasal breathers (control group). Age ranging from 6 to 12 years, both male and female. To measure the vestibular surface of the incisors, it was divided into 3 segments: cervical, medial and incisal. The average of the results pertaining to the mouth breathing patients was as follows: tooth 11 cervical third - 5.45, medial third - 7.15, incisal third - 7.95, and tooth 21 - cervical third - 5.95, medial third - 7.25, incisal third - 8.15. The control patients, nasal breathers, presented the following results: tooth 11 cervical third - 1.75, medial third - 2.30, incisal third - 1.85, and tooth 21 - cervical third - 1.80, medial third - 2.20, incisal third - 2.15. The mouth breathing patients showed demineralization in the teeth examined at the initial stage, subclinical, comparing with the control patients, nasal breathers, who did not present any mineral deficit in these teeth.

  1. The SCUBA-2 Cosmology Legacy Survey: the EGS deep field - I. Deep number counts and the redshift distribution of the recovered cosmic infrared background at 450 and 850 μ m

    NASA Astrophysics Data System (ADS)

    Zavala, J. A.; Aretxaga, I.; Geach, J. E.; Hughes, D. H.; Birkinshaw, M.; Chapin, E.; Chapman, S.; Chen, Chian-Chou; Clements, D. L.; Dunlop, J. S.; Farrah, D.; Ivison, R. J.; Jenness, T.; Michałowski, M. J.; Robson, E. I.; Scott, Douglas; Simpson, J.; Spaans, M.; van der Werf, P.

    2017-01-01

    We present deep observations at 450 and 850 μm in the Extended Groth Strip field taken with the SCUBA-2 camera mounted on the James Clerk Maxwell Telescope as part of the deep SCUBA-2 Cosmology Legacy Survey (S2CLS), achieving a central instrumental depth of σ450 = 1.2 mJy beam-1 and σ850 = 0.2 mJy beam-1. We detect 57 sources at 450 μm and 90 at 850 μm with signal-to-noise ratio >3.5 over ˜70 arcmin2. From these detections, we derive the number counts at flux densities S450 > 4.0 mJy and S850 > 0.9 mJy, which represent the deepest number counts at these wavelengths derived using directly extracted sources from only blank-field observations with a single-dish telescope. Our measurements smoothly connect the gap between previous shallower blank-field single-dish observations and deep interferometric ALMA results. We estimate the contribution of our SCUBA-2 detected galaxies to the cosmic infrared background (CIB), as well as the contribution of 24 μm-selected galaxies through a stacking technique, which add a total of 0.26 ± 0.03 and 0.07 ± 0.01 MJy sr-1, at 450 and 850 μm, respectively. These surface brightnesses correspond to 60 ± 20 and 50 ± 20 per cent of the total CIB measurements, where the errors are dominated by those of the total CIB. Using the photometric redshifts of the 24 μm-selected sample and the redshift distributions of the submillimetre galaxies, we find that the redshift distribution of the recovered CIB is different at each wavelength, with a peak at z ˜ 1 for 450 μm and at z ˜ 2 for 850 μm, consistent with previous observations and theoretical models.

  2. A SCUBA-2 850-μm survey of protoplanetary discs in the IC 348 cluster

    NASA Astrophysics Data System (ADS)

    Cieza, L.; Williams, J.; Kourkchi, E.; Andrews, S.; Casassus, S.; Graves, S.; Schreiber, M. R.

    2015-12-01

    We present 850-μm observations of the 2-3 Myr cluster IC 348 in the Perseus molecular cloud using the SCUBA-2 camera on the James Clerk Maxwell Telescope. Our SCUBA-2 map has a diameter of 30 arcmin and contains ˜370 cluster members, including ˜200 objects with IR excesses. We detect a total of 13 discs. Assuming standard dust properties and a gas-to-dust-mass ratio of 100, we derive disc masses ranging from 1.5 to 16 MJUP. We also detect six Class 0/I protostars. We find that the most massive discs (MD > 3 MJUP; 850-μm flux > 10 mJy) in IC 348 tend to be transition objects according to the characteristic `dip' in their infrared spectral energy distributions (SEDs). This trend is also seen in other regions. We speculate that this could be an initial conditions effect (e.g. more massive discs tend to form giant planets that result in transition disc SEDs) and/or a disc evolution effect (the formation of one or more massive planets results in both a transition disc SED and a reduction of the accretion rate, increasing the lifetime of the outer disc). A stacking analysis of the discs that remain undetected in our SCUBA-2 observations suggests that their median 850-μm flux should be ≲1 mJy, corresponding to a disc mass ≲0.3 MJUP (gas plus dust) or ≲1 M⊕ of dust. While the available data are not deep enough to allow a meaningful comparison of the disc luminosity functions between IC 348 and other young stellar clusters, our results imply that disc masses exceeding the minimum-mass solar nebula are very rare (≲1per cent) at the age of IC 348, especially around very low-mass stars.

  3. KSC-2013-2699

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - NASA Kennedy Space Center Lead Engineer David Bush, center, demos a small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, at BCS Life Support in Titusville, Fla. The CryoBA and a larger Cryogenic Refuge Alternative Supply System, or CryoRASS, are being developed by a Kennedy engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  4. KSC-2013-2822

    NASA Image and Video Library

    2013-06-19

    CAPE CANAVERAL, Fla. - NASA Kennedy Space Center Lead Engineer David Bush works on a prototype of a Cryogenic Refuge Alternative Supply System, or CryoRASS, in the Operations and Checkout Building. CryoRASS and a small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, are being developed by a NASA Kennedy Space Center engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Jim Gossmann

  5. KSC-2013-2823

    NASA Image and Video Library

    2013-06-19

    CAPE CANAVERAL, Fla. - NASA Kennedy Space Center Lead Engineer David Bush works on a prototype of a Cryogenic Refuge Alternative Supply System, or CryoRASS, in the Operations and Checkout Building. CryoRASS and a small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, are being developed by a NASA Kennedy Space Center engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Jim Gossmann

  6. KSC-2013-2701

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - Representatives from NASA Kennedy Space Center, BCS Life Support, LabTech and URS demo a Cryogenic Refuge Alternative Supply System, or CryoRASS, and a smaller liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, in Titusville, Fla. The two systems are being developed by a Kennedy engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  7. KSC-2013-2697

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - Representatives from NASA Kennedy Space Center, BCS Life Support, LabTech and URS prepare to demo a Cryogenic Refuge Alternative Supply System, or CryoRASS, and a smaller liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, in Titusville, Fla. The two systems are being developed by a Kennedy engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  8. KSC-2013-2698

    NASA Image and Video Library

    2013-06-13

    TITUSVILLE, Fla. - NASA Kennedy Space Center Lead Engineer David Bush, right, demos a small liquid-air filled backpack called CryoBA, short for Cryogenic Breathing Apparatus, at BCS Life Support in Titusville, Fla. The CryoBA and a larger Cryogenic Refuge Alternative Supply System, or CryoRASS, are being developed by a Kennedy engineering team in collaboration with The National Institute for Occupational Safety and Health to provide miners with twice the amount of breathable and cooler air than traditional compressed systems. The technology also could be used for commercial applications, such as fire and military rescue operations, as well as NASA's future human spaceflight missions. Photo credit: NASA/Daniel Casper

  9. [Continuous inflation of a leaking cuff of an intubation tube].

    PubMed

    Boussard, N; Helmer, J; Rose, E; Lascombes, P

    1988-01-01

    Perforation of the cuff of the endotracheal tube peroperatively is a very serious problem, especially when it occurs in a patient prone on an orthopaedic table. This is even more dramatic when the patient is not breathing spontaneously and he cannot be turned over to be reintubated. Given the unusual character of this situation, an apparatus has been designed to keep the cuff inflated permanently. It was a circuit consisting of a manual pressure valve, flexible tubing, a peripheral catheter and the cuff supply tube. The gas used was medical air at 3 bar pressure. This method proved perfectly safe and efficient, the operation having continued without reintubation.

  10. The Geminga pulsar wind nebula in the mid-infrared and submillimetre

    NASA Astrophysics Data System (ADS)

    Greaves, J. S.; Holland, W. S.

    2017-10-01

    The nearby middle-aged Geminga pulsar has crossed the Galactic plane within the last ∼0.1 Myr. We present archival data from Wide-field Infrared Survey Explorer and from SCUBA and SCUBA-2 on the James Clerk Maxwell Telescope to assess whether any mid-infrared and submillimetre emission arises from interaction of the pulsar wind nebula with the interstellar medium. A candidate shell and bow shock are reported. Given the low pulsar velocity and local density, dust grains appear able to penetrate into the nebula. A compact source seen towards the pulsar is fitted with a dust spectrum. If confirmed as a real association at higher resolution, this could be a circum-pulsar disc of at least a few Earth-masses, in which future planets could form.

  11. Scuba Diving Safety

    MedlinePlus

    ... and other surface injuries. Fish, coral, or other marine life can cause these. Other threats include debris, ... Aid and Injury Prevention Crisis Situations Pets and Animals myhealthfinder Food and Nutrition Healthy Food Choices Weight ...

  12. Physiological responses and air consumption during simulated firefighting tasks in a subway system.

    PubMed

    Williams-Bell, F Michael; Boisseau, Geoff; McGill, John; Kostiuk, Andrew; Hughson, Richard L

    2010-10-01

    Professional firefighters (33 men, 3 women), ranging in age from 30 to 53 years, participated in a simulation of a subway system search and rescue while breathing from their self-contained breathing apparatus (SCBA). We tested the hypothesis that during this task, established by expert firefighters to be of moderate intensity, the rate of air consumption would exceed the capacity of a nominal 30-min cylinder. Oxygen uptake, carbon dioxide output, and air consumption were measured with a portable breath-by-breath gas exchange analysis system, which was fully integrated with the expired port of the SCBA. The task involved descending a flight of stairs, walking, performing a search and rescue, retreat walking, then ascending a single flight of stairs to a safe exit. This scenario required between 9:56 and 13:24 min:s (mean, 12:10 ± 1:10 min:s) to complete, with an average oxygen uptake of 24.3 ± 4.5 mL kg(-1) min(-1) (47 ± 10 % peak oxygen uptake) and heart rate of 76% ± 7% of maximum. The highest energy requirement was during the final single-flight stair climb (30.4 ± 5.4 mL kg(-1) min(-1)). The average respiratory exchange ratio (carbon dioxide output/oxygen uptake) throughout the scenario was 0.95 ± 0.08, indicating a high carbon dioxide output for a relatively moderate average energy requirement. Air consumption from the nominal "30-min" cylinder averaged 51% (range, 26%-68%); however, extrapolation of these rates of consumption suggested that the low-air alarm, signalling that only 25% of the air remains, would have occurred as early as 11 min for an individual with the highest rate of air consumption, and at 16 min for the group average. These data suggest that even the moderate physical demands of walking combined with search and rescue while wearing full protective gear and breathing through the SCBA impose considerable physiological strain on professional firefighters. As well, the rate of air consumption in these tasks classed as moderate, compared with high-rise firefighting, would have depleted the air supply well before the nominal time used to describe the cylinders.

  13. Divers Alert Network

    MedlinePlus

    ... is Your Dive Safety Association Divers Alert Network DAN is Divers Alert Network, the diving industry’s largest ... Serving scuba divers for more than 30 years, DAN provides emergency assistance, medical information resources, educational opportunities ...

  14. The SCUBA-2 cosmology legacy survey: Ultraluminous star-forming galaxies in a z = 1.6 cluster

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smail, Ian; Swinbank, A. M.; Danielson, A. L. R.

    2014-02-10

    We analyze new SCUBA-2 submillimeter and archival SPIRE far-infrared imaging of a z = 1.62 cluster, Cl 0218.3–0510, which lies in the UKIRT Infrared Deep Sky Survey/Ultra-Deep Survey field of the SCUBA-2 Cosmology Legacy Survey. Combining these tracers of obscured star-formation activity with the extensive photometric and spectroscopic information available for this field, we identify 31 far-infrared/submillimeter-detected probable cluster members with bolometric luminosities ≳10{sup 12} L {sub ☉} and show that by virtue of their dust content and activity, these represent some of the reddest and brightest galaxies in this structure. We exploit ALMA submillimeter continuum observations, which cover onemore » of these sources, to confirm the identification of a SCUBA-2-detected ultraluminous star-forming galaxy in this structure. Integrating the total star-formation activity in the central region of the structure, we estimate that it is an order of magnitude higher (in a mass-normalized sense) than clusters at z ∼ 0.5-1. However, we also find that the most active cluster members do not reside in the densest regions of the structure, which instead host a population of passive and massive, red galaxies. We suggest that while the passive and active populations have comparable near-infrared luminosities at z = 1.6, M{sub H} ∼ –23, the subsequent stronger fading of the more active galaxies means that they will evolve into passive systems at the present day that are less luminous than the descendants of those galaxies that were already passive at z ∼ 1.6 (M{sub H} ∼ –20.5 and M{sub H} ∼ –21.5, respectively, at z ∼ 0). We conclude that the massive galaxy population in the dense cores of present-day clusters were already in place at z = 1.6 and that in Cl 0218.3–0510 we are seeing continuing infall of less extreme, but still ultraluminous, star-forming galaxies onto a pre-existing structure.« less

  15. The JCMT Gould Belt Survey: first results from the SCUBA-2 observations of the Ophiuchus molecular cloud and a virial analysis of its prestellar core population

    NASA Astrophysics Data System (ADS)

    Pattle, K.; Ward-Thompson, D.; Kirk, J. M.; White, G. J.; Drabek-Maunder, E.; Buckle, J.; Beaulieu, S. F.; Berry, D. S.; Broekhoven-Fiene, H.; Currie, M. J.; Fich, M.; Hatchell, J.; Kirk, H.; Jenness, T.; Johnstone, D.; Mottram, J. C.; Nutter, D.; Pineda, J. E.; Quinn, C.; Salji, C.; Tisi, S.; Walker-Smith, S.; di Francesco, J.; Hogerheijde, M. R.; André, Ph.; Bastien, P.; Bresnahan, D.; Butner, H.; Chen, M.; Chrysostomou, A.; Coude, S.; Davis, C. J.; Duarte-Cabral, A.; Fiege, J.; Friberg, P.; Friesen, R.; Fuller, G. A.; Graves, S.; Greaves, J.; Gregson, J.; Griffin, M. J.; Holland, W.; Joncas, G.; Knee, L. B. G.; Könyves, V.; Mairs, S.; Marsh, K.; Matthews, B. C.; Moriarty-Schieven, G.; Rawlings, J.; Richer, J.; Robertson, D.; Rosolowsky, E.; Rumble, D.; Sadavoy, S.; Spinoglio, L.; Thomas, H.; Tothill, N.; Viti, S.; Wouterloot, J.; Yates, J.; Zhu, M.

    2015-06-01

    In this paper, we present the first observations of the Ophiuchus molecular cloud performed as part of the James Clerk Maxwell Telescope (JCMT) Gould Belt Survey (GBS) with the SCUBA-2 instrument. We demonstrate methods for combining these data with previous HARP CO, Herschel, and IRAM N2H+ observations in order to accurately quantify the properties of the SCUBA-2 sources in Ophiuchus. We produce a catalogue of all of the sources found by SCUBA-2. We separate these into protostars and starless cores. We list all of the starless cores and perform a full virial analysis, including external pressure. This is the first time that external pressure has been included in this level of detail. We find that the majority of our cores are either bound or virialized. Gravitational energy and external pressure are on average of a similar order of magnitude, but with some variation from region to region. We find that cores in the Oph A region are gravitationally bound prestellar cores, while cores in the Oph C and E regions are pressure-confined. We determine that N2H+ is a good tracer of the bound material of prestellar cores, although we find some evidence for N2H+ freeze-out at the very highest core densities. We find that non-thermal linewidths decrease substantially between the gas traced by C18O and that traced by N2H+, indicating the dissipation of turbulence at higher densities. We find that the critical Bonnor-Ebert stability criterion is not a good indicator of the boundedness of our cores. We detect the pre-brown dwarf candidate Oph B-11 and find a flux density and mass consistent with previous work. We discuss regional variations in the nature of the cores and find further support for our previous hypothesis of a global evolutionary gradient across the cloud from south-west to north-east, indicating sequential star formation across the region.

  16. Credit WCT. Original 214" x 21/4" color negative is housed ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Credit WCT. Original 2-14" x 2-1/4" color negative is housed in the JPL Photography Laboratory, Pasadena, California. This image depicts the tray dryer for "AP" (ammonium perchlorate, an oxidizer). The dryer was heated by a water jacket; insulated pipes appear at left in the view. In the extreme left foreground appears a marble table similar to the tables used for scales in the weighing room of Building E-35. Note the use of gloves, fireresistant coveralls and breathing apparatus by the JPL employee in view (JPL negative no. JPL-10283BC, 27 January 1989) - Jet Propulsion Laboratory Edwards Facility, Oxidizer Dryer Blender Building, Edwards Air Force Base, Boron, Kern County, CA

  17. STS-60 Cosmonauts in Weightless Environment Training Facility (WETF) training

    NASA Image and Video Library

    1993-01-07

    Russian Cosmonaut Vladimir Titov maneuvers a small life raft during bailout training at JSC's Weightless Environment Training Facility (WETF). Two SCUBA-equipped divers assisted Titov in the STS-60 training exercise.

  18. Patent foramen ovale influences the presentation of decompression illness in SCUBA divers.

    PubMed

    Liou, Kevin; Wolfers, Darren; Turner, Robert; Bennett, Michael; Allan, Roger; Jepson, Nigel; Cranney, Greg

    2015-01-01

    Few have examined the influence of patent foramen ovale (PFO) on the phenotype of decompression illness (DCI) in affected divers. A retrospective review of our database was performed for 75 SCUBA divers over a 10-year period. Overall 4,945 bubble studies were performed at our institution during the study period. Divers with DCI were more likely to have positive bubble studies than other indications (p<0.001). Major DCI was observed significantly more commonly in divers with PFO than those without (18/1,000 v.s. 3/1,000, p=0.02). Divers affected by DCI were also more likely to require a longer course of hyperbaric oxygen therapy (HBOT) if PFO was present (p=0.038). If the patient experienced one or more major DCI symptoms, the odds ratio of PFO being present on a transoesophageal echocardiogram was 3.2 (p=0.02) compared to those who reported no major DCI symptoms. PFO is highly prevalent in selected SCUBA divers with DCI, and is associated with a more severe DCI phenotype and longer duration of HBOT. Patients with unexpected DCI with one or more major DCI symptoms should be offered PFO screening if they choose to continue diving, as it may have considerable prognostic and therapeutic implications. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  19. Exercise after SCUBA diving increases the incidence of arterial gas embolism.

    PubMed

    Madden, Dennis; Lozo, Mislav; Dujic, Zeljko; Ljubkovic, Marko

    2013-09-01

    Arterialization of gas bubbles after decompression from scuba diving has traditionally been associated with pulmonary barotraumas or cardiac defects, such as the patent foramen ovale. Recent studies have demonstrated the right-to-left passage of bubbles through intrapulmonary arterial-venous anastamoses (IPAVA) that allow blood to bypass the pulmonary microcirculation. These passages open up during exercise, and the aim of this study is to see if exercise in a postdiving period increases the incidence of arterialization. After completing a dive to 18 m for 47 min, patent foramen ovale-negative subjects were monitored via transthoracic echocardiography, within 10 min after surfacing, for bubble score at rest. Subjects then completed an incremental cycle ergometry test to exhaustion under continuous transthoracic echocardiography observation. Exercise was suspended if arterialization was observed and resumed when the arterialization cleared. If arterialization was observed a second time, exercise was terminated, and oxygen was administered. Out of 23 subjects, 3 arterialized at rest, 12 arterialized with exercise, and 8 did not arterialize at all even during maximal exercise. The time for arterialization to clear with oxygen was significantly shorter than without. Exercise after diving increased the incidence of arterialization from 13% at rest to 52%. This study shows that individuals are capable of arterializing through IPAVA, and that the intensity at which these open varies by individual. Basic activities associated with SCUBA diving, such as surface swimming or walking with heavy equipment, may be enough to allow the passage of venous gas emboli through IPAVA.

  20. Improved Oxygen Sources for Breathing Apparatus

    NASA Technical Reports Server (NTRS)

    Wood, Peter C.; Wydeven, Theodore

    1985-01-01

    Since the 1920s, the only respiratory protection which coal miners had available during exposure to toxic or irrespirable environments was a filter self-rescuer that catalytically converted carbon monoxide (CO) to carbon dioxide (CO2). The deficiencies of this self-rescuer, which have been described elsewhere (37) led to the support by the Bureau of Mines of the development of a new generation of self-rescuers which utilized potassium superoxide (KO2) as the air-revitalization chemical. Since KO2 reacts with exhaled breath and releases oxygen (O2) while it absorbs CO2, the new self-rescuers were closed-circuit devices which isolated the miner from contact with toxic or irrespirable atmospheres. A device with a one-h duration developed by Lockheed under contract with the Bureau of Mines (18) utilized 1.5 Ib of KO2, weighed 4.54 Ib and measured 6.5 by 3.6 by 7.7 in. Since the earlier, filter self-rescuer weighed about 2.5 lb and was worn continuously by the miner, the one-h, KO2-based device represented a substantial addition to the equipment that the miner was accustomed to carrying and, therefore, was considered to be too large and too heavy.

  1. Experimental and numerical analysis of convergent nozzlex

    NASA Astrophysics Data System (ADS)

    Srinivas, G.; Rakham, Bhupal

    2017-05-01

    In this paper the main focus was given to convergent nozzle where both the experimental and numerical calculations were carried out with the support of standardized literature. In the recent years the field of air breathing and non-air breathing engine developments significantly increase its performance. To enhance the performance of both the type of engines the nozzle is the one of the component which will play a vital role, especially selecting the type of nozzle depends upon the vehicle speed requirement and aerodynamic behavior at most important in the field of propulsion. The convergent nozzle flow experimental analysis done using scaled apparatus and the similar setup was arranged artificially in the ANSYS software for doing the flow analysis across the convergent nozzle. The consistent calculation analysis are done based on the public literature survey to validate the experimental and numerical simulation results of convergent nozzle. Using these two experimental and numerical simulation approaches the best fit results will bring up to meet the design requirements. However the comparison also made to meet the reliability of the work on design criteria of convergent nozzle which can entrench in the field of propulsion applications.

  2. A Thermal Physiological Comparison of Two HazMat Protective Ensembles With and Without Active Convective Cooling

    NASA Technical Reports Server (NTRS)

    Williamson, Rebecca; Carbo, Jorge; Luna, Bernadette; Webbon, Bruce W.

    1998-01-01

    Wearing impermeable garments for hazardous materials clean up can often present a health and safety problem for the wearer. Even short duration clean up activities can produce heat stress injuries in hazardous materials workers. It was hypothesized that an internal cooling system might increase worker productivity and decrease likelihood of heat stress injuries in typical HazMat operations. Two HazMat protective ensembles were compared during treadmill exercise. The different ensembles were created using two different suits: a Trelleborg VPS suit representative of current HazMat suits and a prototype suit developed by NASA engineers. The two life support systems used were a current technology Interspiro Spirolite breathing apparatus and a liquid air breathing system that also provided convective cooling. Twelve local members of a HazMat team served as test subjects. They were fully instrumented to allow a complete physiological comparison of their thermal responses to the different ensembles. Results showed that cooling from the liquid air system significantly decreased thermal stress. The results of the subjective evaluations of new design features in the prototype suit were also highly favorable. Incorporation of these new design features could lead to significant operational advantages in the future.

  3. Using a chemiresistor-based alkane sensor to distinguish exhaled breaths of lung cancer patients from subjects with no lung cancer.

    PubMed

    Tan, Jiunn-Liang; Yong, Zheng-Xin; Liam, Chong-Kin

    2016-10-01

    Breath alkanes are reported to be able to discriminate lung cancer patients from healthy people. A simple chemiresistor-based sensor was designed to respond to alkanes by a change in resistance measured by a digital multimeter connected to the sensor. In preclinical experiments, the sensor response was found to have a strong positive linear relationship with alkane compounds and not responsive to water. This study aimed to determine the ability of the alkane sensor to distinguish the exhaled breaths of lung cancer patients from that of chronic obstructive pulmonary disease (COPD) patients and control subjects without lung cancer. In this cross-sectional study, 12 treatment-naive patients with lung cancer, 12 ex- or current smokers with COPD and 13 never-smokers without lung disease were asked to exhale through a drinking straw into a prototype breath-in apparatus made from an empty 125 mL Vitagen ® bottle with the chemiresistor sensor attached at its inside bottom to measure the sensor peak output (percentage change of baseline resistance measured before exhalation to peak resistance) and the time taken for the baseline resistance to reach peak resistance. Analysis of multivariate variance and post-hoc Tukey test revealed that the peak output and the time to peak values for the lung cancer patients were statistically different from that for both the COPD patients and the controls without lung disease, Pillai's Trace =0.393, F=3.909, df = (4, 64), P=0.007. A 2.20% sensor peak output and a 90-s time to peak gave 83.3% sensitivity and 88% specificity in diagnosing lung cancer. Tobacco smoking did not affect the diagnostic accuracy of the sensor. The alkane sensor could discriminate patients with lung cancer from COPD patients and people without lung disease. Its potential utility as a simple, cheap and non-invasive test for early lung cancer detection needs further studies.

  4. Using a chemiresistor-based alkane sensor to distinguish exhaled breaths of lung cancer patients from subjects with no lung cancer

    PubMed Central

    Tan, Jiunn-Liang; Yong, Zheng-Xin

    2016-01-01

    Background Breath alkanes are reported to be able to discriminate lung cancer patients from healthy people. A simple chemiresistor-based sensor was designed to respond to alkanes by a change in resistance measured by a digital multimeter connected to the sensor. In preclinical experiments, the sensor response was found to have a strong positive linear relationship with alkane compounds and not responsive to water. This study aimed to determine the ability of the alkane sensor to distinguish the exhaled breaths of lung cancer patients from that of chronic obstructive pulmonary disease (COPD) patients and control subjects without lung cancer. Methods In this cross-sectional study, 12 treatment-naive patients with lung cancer, 12 ex- or current smokers with COPD and 13 never-smokers without lung disease were asked to exhale through a drinking straw into a prototype breath-in apparatus made from an empty 125 mL Vitagen® bottle with the chemiresistor sensor attached at its inside bottom to measure the sensor peak output (percentage change of baseline resistance measured before exhalation to peak resistance) and the time taken for the baseline resistance to reach peak resistance. Results Analysis of multivariate variance and post-hoc Tukey test revealed that the peak output and the time to peak values for the lung cancer patients were statistically different from that for both the COPD patients and the controls without lung disease, Pillai’s Trace =0.393, F=3.909, df = (4, 64), P=0.007. A 2.20% sensor peak output and a 90-s time to peak gave 83.3% sensitivity and 88% specificity in diagnosing lung cancer. Tobacco smoking did not affect the diagnostic accuracy of the sensor. Conclusions The alkane sensor could discriminate patients with lung cancer from COPD patients and people without lung disease. Its potential utility as a simple, cheap and non-invasive test for early lung cancer detection needs further studies. PMID:27867553

  5. Recreational technical diving part 1: an introduction to technical diving methods and activities.

    PubMed

    Mitchell, Simon J; Doolette, David J

    2013-06-01

    Technical divers use gases other than air and advanced equipment configurations to conduct dives that are deeper and/or longer than typical recreational air dives. The use of oxygen-nitrogen (nitrox) mixes with oxygen fractions higher than air results in longer no-decompression limits for shallow diving, and faster decompression from deeper dives. For depths beyond the air-diving range, technical divers mix helium, a light non-narcotic gas, with nitrogen and oxygen to produce 'trimix'. These blends are tailored to the depth of intended use with a fraction of oxygen calculated to produce an inspired oxygen partial pressure unlikely to cause cerebral oxygen toxicity and a nitrogen fraction calculated to produce a tolerable degree of nitrogen narcosis. A typical deep technical dive will involve the use of trimix at the target depth with changes to gases containing more oxygen and less inert gas during the decompression. Open-circuit scuba may be used to carry and utilise such gases, but this is very wasteful of expensive helium. There is increasing use of closed-circuit 'rebreather' devices. These recycle expired gas and potentially limit gas consumption to a small amount of inert gas to maintain the volume of the breathing circuit during descent and the amount of oxygen metabolised by the diver. This paper reviews the basic approach to planning and execution of dives using these methods to better inform physicians of the physical demands and risks.

  6. 76 FR 25666 - Submission for OMB Review; Comment Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-05

    ... such as estuaries and sloughs; and snorkeling or scuba diving on fish aggregating devices such as ship wrecks. The survey will help enhance NMFS' understanding of the economic implications of its public trust...

  7. Underwater Education.

    ERIC Educational Resources Information Center

    Somers, Lee H.

    1979-01-01

    The growth of popularity of skin and scuba diving in both educational and recreational programs is discussed along with some of the problems including the qualifications of instructors, national standards for instruction, and the need for informed administrative personnel. (JMF)

  8. The use of superoxide mixtures as air-revitalization chemicals in hyperbaric, self-contained, closed-circuit breathing apparatus

    NASA Technical Reports Server (NTRS)

    Wood, P. C.; Wydeven, T.

    1985-01-01

    In portable breathing apparatus applications at 1 atm, potassium superoxide (KO2) has exhibited low-utilization efficiency of the available oxygen (O2) and diminished carbon dioxide-(CO2) scrubbing capacity caused by the formation of a fused, hydrated-hydroxide/carbonate product coating on the superoxide granules. In earlier work, it was discovered that granules fabricated from an intimate mixture of KO2 and calcium superoxide, Ca(O2)2, did not exhibit formation of a fused product coating and the utilization efficiency with respect to both O2 release and CO2 absorption was superior to KO2 granules when both types of granules were reacted with humidified CO2 under identified conditions. In the work described here, single pellets of KO2, KO2/Ca(O2), mixtures and commercially available KO2 tables and granules were reacted with a flow of humidified CO2 in helium at 1- and 10-atm total pressure and at an initial temperature of 40 C. In the 1-atm flow tests, the reaction rates and utilization efficiency of the KO2/Ca(O2)2 pellets were markedly superior to the KO2 pellets, tablets, and granules when the samples were reacted under identical conditions. However, at 10 atm, the rates of O2 release and CO2 absorption, as well as the utilization efficiencies of all the superoxide samples, were one-third to one-eighth of the values observed at 1 atm. The decrease in reaction performance at 10 atm compared to that at 1 atm has been attributed principally to the lower bulk diffusivity of the CO2 and H2O reactants in helium at the higher pressure and secondarily to the moderation of the reaction temperature caused by the higher heat capacity of the 10-atm helium.

  9. Osteomyelitis of the hyoid bones in two calves.

    PubMed

    Nuss, Karl; Malbon, Alexandra J; Braun, Ueli; Ringer, Simone; Muggli, Evelyne; Kircher, Patrick; Willmitzer, Florian

    2015-09-22

    Two calves were referred because of ptyalism and difficulty opening the mouth (Calf 1) and for elective umbilical hernia surgery under inhalation anaesthesia (Calf 2). Additional clinical signs were increased breath sounds and swelling in the region of the mandibular angle in Calf 1. Ultrasonography and endoscopy revealed oral inflammation and abscessation in the area of the base of the tongue in both calves. Infection of the hyoid apparatus was suspected based on ultrasonographic findings and confirmed by means of computed tomography. In Calf 1, there was no response to treatment with systemic antibiotics, nonsteroidal anti-inflammatory drugs and local lavage, and Calf 2 was not treated. Both calves were euthanized because of a poor prognosis and the diagnoses confirmed during postmortem examination. In Calf 1, the abscess was associated with complete destruction of the left epihyoid bone and partial destruction of the left stylohyoid and ceratohyoid bones. In Calf 2, the abscess was located at the distal end of the right stylohyoid bone near the epihyoid bone. Stomatitis or laryngeal and pharyngeal abscessation caused by sharp feed particles are common in cattle and infection of the hyoid apparatus should be included in the differential diagnosis.

  10. Procedures manual for compressed air diving (scuba mode).

    DOT National Transportation Integrated Search

    1980-01-01

    The Virginia Department of Highways and Transportation conducts underwater inspection, maintenance, and salvage activities as part of its routine operations. These activities are carried out by divers from the private sector working on a contract bas...

  11. The Risks of Scuba Diving: A Focus on Decompression Illness

    PubMed Central

    2014-01-01

    Decompression Illness includes both Decompression Sickness (DCS) and Pulmonary Overinflation Syndrome (POIS), subsets of diving-related injury related to scuba diving. DCS is a condition in which gas bubbles that form while diving do not have adequate time to be resorbed or “off-gassed,” resulting in entrapment in specific regions of the body. POIS is due to an overly rapid ascent to the surface resulting in the rupture of alveoli and subsequent extravasation of air bubbles into tissue planes or even the cerebral circulation. Divers must always be cognizant of dive time and depth, and be trained in the management of decompression. A slow and controlled ascent, plus proper control of buoyancy can reduce the dangerous consequences of pulmonary barotrauma. The incidence of adverse effects can be diminished with safe practices, allowing for the full enjoyment of this adventurous aquatic sport. PMID:25478296

  12. Towards the automated reduction and calibration of SCUBA data from the James Clerk Maxwell Telescope

    NASA Astrophysics Data System (ADS)

    Jenness, T.; Stevens, J. A.; Archibald, E. N.; Economou, F.; Jessop, N. E.; Robson, E. I.

    2002-10-01

    The Submillimetre Common User Bolometer Array (SCUBA) instrument has been operating on the James Clerk Maxwell Telescope (JCMT) since 1997. The data archive is now sufficiently large that it can be used to investigate instrumental properties and the variability of astronomical sources. This paper describes the automated calibration and reduction scheme used to process the archive data, with particular emphasis on `jiggle-map' observations of compact sources. We demonstrate the validity of our automated approach at both 850 and 450 μm, and apply it to several of the JCMT secondary flux calibrators. We determine light curves for the variable sources IRC +10216 and OH 231.8. This automation is made possible by using the ORAC-DR data reduction pipeline, a flexible and extensible data reduction pipeline that is used on the United Kingdom Infrared Telescope (UKIRT) and the JCMT.

  13. SCUBA divers as oceanographic samplers: The potential of dive computers to augment aquatic temperature monitoring

    PubMed Central

    Wright, Serena; Hull, Tom; Sivyer, David B.; Pearce, David; Pinnegar, John K.; Sayer, Martin D. J.; Mogg, Andrew O. M.; Azzopardi, Elaine; Gontarek, Steve; Hyder, Kieran

    2016-01-01

    Monitoring temperature of aquatic waters is of great importance, with modelled, satellite and in-situ data providing invaluable insights into long-term environmental change. However, there is often a lack of depth-resolved temperature measurements. Recreational dive computers routinely record temperature and depth, so could provide an alternate and highly novel source of oceanographic information to fill this data gap. In this study, a citizen science approach was used to obtain over 7,000 scuba diver temperature profiles. The accuracy, offset and lag of temperature records was assessed by comparing dive computers with scientific conductivity-temperature-depth instruments and existing surface temperature data. Our results show that, with processing, dive computers can provide a useful and novel tool with which to augment existing monitoring systems all over the globe, but especially in under-sampled or highly changeable coastal environments. PMID:27445104

  14. Ice-cooled vest for work in hot mines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-04-01

    A specially designed ice-cooled vest is worn while working in hot environments where cooling the mine air is not possible. The vest holds a total of 44 individual ice cells in packets that are firmly held near the wearer's skin. These ice cells remove heat from the wearer, reducing heat stress and increasing comfort. Laboratory testing at Pennsylvania State University showed that the cooling vest greatly prolongs the time that men can work in hot environments. Rescue men, wearing breathing apparatus and working in very humid air at 96/sup 0/F were able to work about 40% longer when using themore » vest. The vest has also been tested for several months in a chemical plant.« less

  15. The JCMT Gould Belt Survey: first results from SCUBA-2 observations of the Cepheus Flare region

    NASA Astrophysics Data System (ADS)

    Pattle, K.; Ward-Thompson, D.; Kirk, J. M.; Di Francesco, J.; Kirk, H.; Mottram, J. C.; Keown, J.; Buckle, J.; Beaulieu, S. F.; Berry, D. S.; Broekhoven-Fiene, H.; Currie, M. J.; Fich, M.; Hatchell, J.; Jenness, T.; Johnstone, D.; Nutter, D.; Pineda, J. E.; Quinn, C.; Salji, C.; Tisi, S.; Walker-Smith, S.; Hogerheijde, M. R.; Bastien, P.; Bresnahan, D.; Butner, H.; Chen, M.; Chrysostomou, A.; Coudé, S.; Davis, C. J.; Drabek-Maunder, E.; Duarte-Cabral, A.; Fiege, J.; Friberg, P.; Friesen, R.; Fuller, G. A.; Graves, S.; Greaves, J.; Gregson, J.; Holland, W.; Joncas, G.; Knee, L. B. G.; Mairs, S.; Marsh, K.; Matthews, B. C.; Moriarty-Schieven, G.; Mowat, C.; Rawlings, J.; Richer, J.; Robertson, D.; Rosolowsky, E.; Rumble, D.; Sadavoy, S.; Thomas, H.; Tothill, N.; Viti, S.; White, G. J.; Wouterloot, J.; Yates, J.; Zhu, M.

    2017-02-01

    We present observations of the Cepheus Flare obtained as part of the James Clerk Maxwell Telescope (JCMT) Gould Belt Legacy Survey (GBLS) with the SCUBA-2 instrument. We produce a catalogue of sources found by SCUBA-2, and separate these into starless cores and protostars. We determine masses and densities for each of our sources, using source temperatures determined by the Herschel Gould Belt Survey. We compare the properties of starless cores in four different molecular clouds: L1147/58, L1172/74, L1251 and L1228. We find that the core mass functions for each region typically show shallower-than-Salpeter behaviour. We find that L1147/58 and L1228 have a high ratio of starless cores to Class II protostars, while L1251 and L1174 have a low ratio, consistent with the latter regions being more active sites of current star formation, while the former are forming stars less actively. We determine that if modelled as thermally supported Bonnor-Ebert spheres, most of our cores have stable configurations accessible to them. We estimate the external pressures on our cores using archival 13CO velocity dispersion measurements and find that our cores are typically pressure confined, rather than gravitationally bound. We perform a virial analysis on our cores, and find that they typically cannot be supported against collapse by internal thermal energy alone, due primarily to the measured external pressures. This suggests that the dominant mode of internal support in starless cores in the Cepheus Flare is either non-thermal motions or internal magnetic fields.

  16. How Do Stars Gain Their Mass? A JCMT/SCUBA-2 Transient Survey of Protostars in Nearby Star-forming Regions

    NASA Astrophysics Data System (ADS)

    Herczeg, Gregory J.; Johnstone, Doug; Mairs, Steve; Hatchell, Jennifer; Lee, Jeong-Eun; Bower, Geoffrey C.; Chen, Huei-Ru Vivien; Aikawa, Yuri; Yoo, Hyunju; Kang, Sung-Ju; Kang, Miju; Chen, Wen-Ping; Williams, Jonathan P.; Bae, Jaehan; Dunham, Michael M.; Vorobyov, Eduard I.; Zhu, Zhaohuan; Rao, Ramprasad; Kirk, Helen; Takahashi, Satoko; Morata, Oscar; Lacaille, Kevin; Lane, James; Pon, Andy; Scholz, Aleks; Samal, Manash R.; Bell, Graham S.; Graves, Sarah; Lee, E.'lisa M.; Parsons, Harriet; He, Yuxin; Zhou, Jianjun; Kim, Mi-Ryang; Chapman, Scott; Drabek-Maunder, Emily; Chung, Eun Jung; Eyres, Stewart P. S.; Forbrich, Jan; Hillenbrand, Lynne A.; Inutsuka, Shu-ichiro; Kim, Gwanjeong; Kim, Kyoung Hee; Kuan, Yi-Jehng; Kwon, Woojin; Lai, Shih-Ping; Lalchand, Bhavana; Lee, Chang Won; Lee, Chin-Fei; Long, Feng; Lyo, A.-Ran; Qian, Lei; Scicluna, Peter; Soam, Archana; Stamatellos, Dimitris; Takakuwa, Shigehisa; Tang, Ya-Wen; Wang, Hongchi; Wang, Yiren

    2017-11-01

    Most protostars have luminosities that are fainter than expected from steady accretion over the protostellar lifetime. The solution to this problem may lie in episodic mass accretion—prolonged periods of very low accretion punctuated by short bursts of rapid accretion. However, the timescale and amplitude for variability at the protostellar phase is almost entirely unconstrained. In A James Clerk Maxwell Telescope/SCUBA-2 Transient Survey of Protostars in Nearby Star-forming Regions, we are monitoring monthly with SCUBA-2 the submillimeter emission in eight fields within nearby (< 500 pc) star-forming regions to measure the accretion variability of protostars. The total survey area of ˜1.6 deg2 includes ˜105 peaks with peaks brighter than 0.5 Jy/beam (43 associated with embedded protostars or disks) and 237 peaks of 0.125-0.5 Jy/beam (50 with embedded protostars or disks). Each field has enough bright peaks for flux calibration relative to other peaks in the same field, which improves upon the nominal flux calibration uncertainties of submillimeter observations to reach a precision of ˜2%-3% rms, and also provides quantified confidence in any measured variability. The timescales and amplitudes of any submillimeter variation will then be converted into variations in accretion rate and subsequently used to infer the physical causes of the variability. This survey is the first dedicated survey for submillimeter variability and complements other transient surveys at optical and near-IR wavelengths, which are not sensitive to accretion variability of deeply embedded protostars.

  17. Variability in circulating gas emboli after a same scuba diving exposure.

    PubMed

    Papadopoulou, V; Germonpré, P; Cosgrove, D; Eckersley, R J; Dayton, P A; Obeid, G; Boutros, A; Tang, M-X; Theunissen, S; Balestra, C

    2018-06-01

    A reduction in ambient pressure or decompression from scuba diving can result in ultrasound-detectable venous gas emboli (VGE). These environmental exposures carry a risk of decompression sickness (DCS) which is mitigated by adherence to decompression schedules; however, bubbles are routinely observed for dives well within these limits and significant inter-personal variability in DCS risk exists. Here, we assess the variability and evolution of VGE for 2 h post-dive using echocardiography, following a standardized pool dive in calm warm conditions. 14 divers performed either one or two (with a 24 h interval) standardized scuba dives to 33 mfw (400 kPa) for 20 min of immersion time at NEMO 33 in Brussels, Belgium. Measurements were performed at 21, 56, 91 and 126 min post-dive: bubbles were counted for all 68 echocardiography recordings and the average over ten consecutive cardiac cycles taken as the bubble score. Significant inter-personal variability was demonstrated despite all divers following the same protocol in controlled pool conditions: in the detection or not of VGE, in the peak VGE score, as well as time to VGE peak. In addition, intra-personal differences in 2/3 of the consecutive day dives were seen (lower VGE counts or faster clearance). Since VGE evolution post-dive varies between people, more work is clearly needed to isolate contributing factors. In this respect, going toward a more continuous evaluation, or developing new means to detect decompression stress markers, may offer the ability to better assess dynamic correlations to other physiological parameters.

  18. High intensity cycling before SCUBA diving reduces post-decompression microparticle production and neutrophil activation.

    PubMed

    Madden, Dennis; Thom, Stephen R; Yang, Ming; Bhopale, Veena M; Ljubkovic, Marko; Dujic, Zeljko

    2014-09-01

    Venous gas emboli (VGE) have traditionally served as a marker for decompression stress after SCUBA diving and a reduction in bubble loads is a target for precondition procedures. However, VGE can be observed in large quantities with no negative clinical consequences. The effect of exercise before diving on VGE has been evaluated with mixed results. Microparticle (MP) counts and sub-type expression serve as indicators of vascular inflammation and DCS in mice. The goal of the present study is to evaluate the effect of anaerobic cycling (AC) on VGE and MP following SCUBA diving. Ten male divers performed two dives to 18 m for 41 min, one dive (AC) was preceded by a repeated-Wingate cycling protocol; a control dive (CON) was completed without exercise. VGE were analyzed at 15, 40, 80, and 120 min post-diving. Blood for MP analysis was collected before exercise (AC only), before diving, 15 and 120 min after surfacing. VGE were significantly lower 15 min post-diving in the AC group, with no difference in the remaining measurements. MPs were elevated by exercise and diving, however, post-diving elevations were attenuated in the AC dive. Some markers of neutrophil elevation (CD18, CD41) were increased in the CON compared to the AC dive. The repeated-Wingate protocol resulted in an attenuation of MP counts and sub-types that have been related to vascular injury and DCS-like symptoms in mice. Further studies are needed to determine if MPs represent a risk factor or marker for DCS in humans.

  19. Criteria for determining safe water conditions for underwater operations.

    DOT National Transportation Integrated Search

    1984-01-01

    Virginia Department of Highways and Transportation employees trained in the use of SCUBA inspect certain of the Department's bridges and provide a degree of quality control for inspections done under contract. Safety standards to be followed in divin...

  20. 11. VIEW, LOOKING EAST FROM LEFT TO RIGHT, SHOWING UNDERWATER ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. VIEW, LOOKING EAST FROM LEFT TO RIGHT, SHOWING UNDERWATER WELDING/SCUBA ROOM, CLASSROOM BUILDING, AND MEDICAL RESEARCH LABORATORY ANNEX - U.S. Naval Submarine Base, New London Submarine Escape Training Tank, Albacore & Darter Roads, Groton, New London County, CT

  1. A caseian point for the evolution of a diaphragm homologue among the earliest synapsids.

    PubMed

    Lambertz, Markus; Shelton, Christen D; Spindler, Frederik; Perry, Steven F

    2016-12-01

    The origin of the diaphragm remains a poorly understood yet crucial step in the evolution of terrestrial vertebrates, as this unique structure serves as the main respiratory motor for mammals. Here, we analyze the paleobiology and the respiratory apparatus of one of the oldest lineages of mammal-like reptiles: the Caseidae. Combining quantitative bone histology and functional morphological and physiological modeling approaches, we deduce a scenario in which an auxiliary ventilatory structure was present in these early synapsids. Crucial to this hypothesis are indications that at least the phylogenetically advanced caseids might not have been primarily terrestrial but rather were bound to a predominantly aquatic life. Such a lifestyle would have resulted in severe constraints on their ventilatory system, which consequently would have had to cope with diving-related problems. Our modeling of breathing parameters revealed that these caseids were capable of only limited costal breathing and, if aquatic, must have employed some auxiliary ventilatory mechanism to quickly meet their oxygen demand upon surfacing. Given caseids' phylogenetic position at the base of Synapsida and under this aquatic scenario, it would be most parsimonious to assume that a homologue of the mammalian diaphragm had already evolved about 50 Ma earlier than previously assumed. © 2016 New York Academy of Sciences.

  2. Association of microparticles and neutrophil activation with decompression sickness.

    PubMed

    Thom, Stephen R; Bennett, Michael; Banham, Neil D; Chin, Walter; Blake, Denise F; Rosen, Anders; Pollock, Neal W; Madden, Dennis; Barak, Otto; Marroni, Alessandro; Balestra, Costantino; Germonpre, Peter; Pieri, Massimo; Cialoni, Danilo; Le, Phi-Nga Jeannie; Logue, Christopher; Lambert, David; Hardy, Kevin R; Sward, Douglas; Yang, Ming; Bhopale, Veena B; Dujic, Zeljko

    2015-09-01

    Decompression sickness (DCS) is a systemic disorder, assumed due to gas bubbles, but additional factors are likely to play a role. Circulating microparticles (MPs)--vesicular structures with diameters of 0.1-1.0 μm--have been implicated, but data in human divers have been lacking. We hypothesized that the number of blood-borne, Annexin V-positive MPs and neutrophil activation, assessed as surface MPO staining, would differ between self-contained underwater breathing-apparatus divers suffering from DCS vs. asymptomatic divers. Blood was analyzed from 280 divers who had been exposed to maximum depths from 7 to 105 meters; 185 were control/asymptomatic divers, and 90 were diagnosed with DCS. Elevations of MPs and neutrophil activation occurred in all divers but normalized within 24 h in those who were asymptomatic. MPs, bearing the following proteins: CD66b, CD41, CD31, CD142, CD235, and von Willebrand factor, were between 2.4- and 11.7-fold higher in blood from divers with DCS vs. asymptomatic divers, matched for time of sample acquisition, maximum diving depth, and breathing gas. Multiple logistic regression analysis documented significant associations (P < 0.001) between DCS and MPs and for neutrophil MPO staining. Effect estimates were not altered by gender, body mass index, use of nonsteroidal anti-inflammatory agents, or emergency oxygen treatment and were modestly influenced by divers' age, choice of breathing gas during diving, maximum diving depth, and whether repetitive diving had been performed. There were no significant associations between DCS and number of MPs without surface proteins listed above. We conclude that MP production and neutrophil activation exhibit strong associations with DCS. Copyright © 2015 the American Physiological Society.

  3. Rapid CO breath test screening of drugs for protective effects on ribavirin-induced hemolysis in a rabbit model: a pilot study.

    PubMed

    Ma, Yong-Jian; Zhang, Hou-De; Wu, Chuang-Hong; Zhu, Guo-Liang; Ji, Yong-Qiang; Huang, Jia-Liang; Du, Li-Tao; Cao, Ping; Zang, De-Yue; Ji, Kun-Mei

    2016-08-10

    Hemolytic anemia is a major side effect of ribavirin antiviral treatment for chronic hepatitis C. Ribavirin dose reduction may compromise the antiviral response and erythropoietin can take several weeks to alleviate anemia. The purpose of the present study was to screen potentially protective drugs against ribavirin-induced hemolytic anemia in a rabbit model, using our modified CO breath test for measuring erythrocyte (RBC) lifespan, the gold standard diagnostic index of hemolysis. Fifteen rabbits were divided randomly into five groups (N  =  3/group): one vehicle control group, one ribavirin (only)-treated (RBV) group, and three groups initially treated with ribavirin only, followed by a combination of ribavirin with prednisone (RBV  +  Pred), polyene phosphatidyl choline (RBV  +  PPC), or reduced glutathione (RBV  +  GSH). RBC lifespan was calculated from accumulated CO measured in a closed rebreath apparatus, blood volume measured by the Evan's blue dye (EBD) dilution test, and hemoglobin concentration data. The RBC lifespan was normal in the vehicle control group (44-60 d), but reduced significantly in all of the ribavirin-treated groups before the addition of screened drugs (17-35 d). RBC lifespan rebounded significantly with the addition of glutathione, but not with the addition of prednisone or polyene phosphatidyl choline. A similar overall drug effect pattern was seen in the hemoglobin concentration and reticulocyte count data. In conclusion, the results of this pilot study indicate that reduced glutathione can attenuate ribavirin-induced hemolytic anemia, and that the RBC lifespan measured with our modified rapid CO breath test is feasible and reliable for use in animal studies.

  4. Procedures for conducting underwater searches for invasive mussels (Dreissena sp.)

    USGS Publications Warehouse

    Adams, Noah

    2010-01-01

    Zebra mussels (Dreissena polymorpha) were first detected in the Great Lakes in 1988. They were likely transported as larvae or young adults inside the ballast tanks of large ocean-going ships originating from Europe. Since their introduction, they have spread throughout the Eastern, Midwestern, and Southern United States. In 2007, Quagga mussels (Dreissena rostriformis bugensis) were found in the Western United States in Lake Mead, Nevada; part of the Lower Colorado River Basin. State and Federal managers are concerned that the mussels (hereafter referred to as dreissenid mussels or mussels) will continue to spread to the Columbia River Basin and have a major impact on the region?s ecosystem, water delivery infrastructure, hydroelectric projects, and the economy. The transport and use of recreational watercraft throughout the Western United States could easily result in spreading mussels to the Columbia River Basin. The number of recreational watercraft using Lake Mead can range from 350 to 3,500 a day (Bryan Moore, National Park Service, oral commun., June 21, 2008). Because recreational watercrafts are readily moved around and mussels may survive for a period of time when they are out of the water, there is a high potential to spread mussels from Lake Mead to other waterways in the Western United States. Efforts are being made to prevent the spread of mussels; however, there is great concern that these efforts will not be 100 percent successful. When prevention efforts fail, early detection of mussels may provide an opportunity to implement rapid response management actions to minimize the impact. Control and eradication efforts are more likely to be successful if they are implemented when the density of mussels is low and the area of infestation is small. Once the population grows and becomes established, the mussels are extremely difficult, if not impossible, to control. Although chemicals may be used to kill the mussels, the chemicals that are currently available also can kill other aquatic life. Early implementation of containment and eradication efforts requires getting reliable information to confirm the location of the infestation. One way to get this information is through the use of properly trained SCUBA divers. This document provides SCUBA divers with the necessary information to conduct underwater searchers for mussels. However, using SCUBA divers to search for mussels over a large geographic area is relatively expensive and inefficient. Early detection monitoring methods can be used to optimize the use of SCUBA divers. Early detection monitoring can be accomplished by collecting water samples or deploying artificial settlement substrates (fig. 1). Water samples are used to look for free-swimming larval mussels (called veligers). Because the veligers cannot be identified with the naked eye, the water samples are sent to a laboratory where they are examined under a microscope and/or analyzed using molecular techniques to detect veligers. To detect the presences of adult mussels, artificial substrates are deployed and periodically retrieved to determine if mussels have settled on the substrate. If veligers or adults are identified, SCUBA divers can be deployed to confirm the presence of mussels.

  5. The SCUBA-2 Cosmology Legacy Survey: galaxies in the deep 850 μm survey, and the star-forming `main sequence'

    NASA Astrophysics Data System (ADS)

    Koprowski, M. P.; Dunlop, J. S.; Michałowski, M. J.; Roseboom, I.; Geach, J. E.; Cirasuolo, M.; Aretxaga, I.; Bowler, R. A. A.; Banerji, M.; Bourne, N.; Coppin, K. E. K.; Chapman, S.; Hughes, D. H.; Jenness, T.; McLure, R. J.; Symeonidis, M.; Werf, P. van der

    2016-06-01

    We investigate the properties of the galaxies selected from the deepest 850-μm survey undertaken to date with (Submillimetre Common-User Bolometer Array 2) SCUBA-2 on the James Clerk Maxwell Telescope as part of the SCUBA-2 Cosmology Legacy Survey. A total of 106 sources (>5σ) were uncovered at 850 μm from an area of ≃150 arcmin2 in the centre of the COSMOS/UltraVISTA/Cosmic Assembly Near-infrared Deep Extragalactic Legacy Survey (CANDELS) field, imaged to a typical depth of σ850 ≃ 0.25 mJy. We utilize the available multifrequency data to identify galaxy counterparts for 80 of these sources (75 per cent), and to establish the complete redshift distribution for this sample, yielding bar{z} = 2.38± 0.09. We have also been able to determine the stellar masses of the majority of the galaxy identifications, enabling us to explore their location on the star formation rate:stellar mass (SFR:M*) plane. Crucially, our new deep 850-μm-selected sample reaches flux densities equivalent to SFR ≃ 100 M⊙ yr-1, enabling us to confirm that sub-mm galaxies form the high-mass end of the `main sequence' (MS) of star-forming galaxies at z > 1.5 (with a mean specific SFR of sSFR = 2.25 ± 0.19 Gyr-1 at z ≃ 2.5). Our results are consistent with no significant flattening of the MS towards high masses at these redshifts. However, our results add to the growing evidence that average sSFR rises only slowly at high redshift, resulting in log10sSFR being an apparently simple linear function of the age of the Universe.

  6. Recreational SCUBA divers' willingness to pay for marine biodiversity in Barbados.

    PubMed

    Schuhmann, Peter W; Casey, James F; Horrocks, Julia A; Oxenford, Hazel A

    2013-05-30

    The use of natural resources and the services they provide often do not have an explicit price and are therefore undervalued in decision-making, leading to environmental degradation. To 'monetize' the benefits from these services requires the use of non-market valuation techniques. Using a stated preference survey of recreational divers in Barbados conducted between 2007 and 2009, the economic value of marine biodiversity to recreational SCUBA divers in Barbados was estimated. In addition to a variety of demographic variables, divers were asked about their level of experience, expenditures related to travel and diving, and encounters with fish and sea turtles. Divers then completed a choice experiment, selecting between alternative dives with varying characteristics including price, crowding, fish diversity, encounters with sea turtles, and coral cover. Results indicate that divers in Barbados have a clear appreciation of reef quality variables. Willingness to pay for good coral cover, fish diversity and presence of sea turtles is significantly higher than prices paid for dives. In general, divers valued reef attributes similarly, although their appreciation of low density of divers at a site and high coral cover varied with prior diving experience. The results of this study demonstrate the economic value generated in Barbados by the recreational SCUBA diving industry and highlight the potential for substantial additional economic contributions with improvements to the quality of a variety of reef attributes. These results could inform management decisions regarding reef use and sea turtle conservation, and could aid in the development of informed 'win-win' policies aimed at maximizing returns from diving while reducing negative impacts often associated with tourism activities. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. SCUBA and HIRES Results for Protostellar Cores in the MON OB1 Dark Cloud

    NASA Astrophysics Data System (ADS)

    Wolf-Chase, G.; Moriarty-Schieven, G.; Fich, M.; Barsony, M.

    1999-05-01

    We have used HIRES-processing of IRAS data and point-source modelling techniques (Hurt & Barsony 1996; O'Linger 1997; Barsony et al. 1998), together with submillimeter continuum imaging using the Submillimeter Common-User Bolometer Array (SCUBA) on the 15-meter James Clerk Maxwell Telescope (JCMT), to search CS cores in the Mon OB1 dark cloud (Wolf-Chase, Walker, & Lada 1995; Wolf-Chase & Walker 1995) for deeply embedded sources. These observations, as well as follow-up millimeter photometry at the National Radio Astronomy Observatory (NRAO) 12-meter telescope on Kitt Peak, have lead to the identification of two Class 0 protostellar candidates, which were previously unresolved from two brighter IRAS point sources (IRAS 06382+0939 & IRAS 06381+1039) in this cloud. Until now, only one Class 0 object had been confirmed in Mon OB1; the driving source of the highly-collimated outflow NGC 2264 G (Ward-Thompson, Eiroa, & Casali 1995; Margulis et al. 1990; Lada & Fich 1996), which lies well outside the extended CS cores. One of the new Class 0 candidates may be an intermediate-mass source associated with an H_2O maser, and the other object is a low-mass source which may be associated with a near-infrared jet, and possibly with a molecular outflow. We report accurate positions for the new Class 0 candidates, based on the SCUBA images, and present new SEDs for these sources, as well as for the brighter IRAS point sources. A portion of this work was performed while GWC held a President's Fellowship from the University of California. MB and GWC gratefully acknowledge financial support from MB's NSF CAREER Grant, AST97-9753229.

  8. The JCMT Gould Belt Survey: the effect of molecular contamination in SCUBA-2 observations of Orion A

    NASA Astrophysics Data System (ADS)

    Coudé, S.; Bastien, P.; Kirk, H.; Johnstone, D.; Drabek-Maunder, E.; Graves, S.; Hatchell, J.; Chapin, E. L.; Gibb, A. G.; Matthews, B.; JCMT Gould Belt Survey Team

    2016-04-01

    Thermal emission from cold dust grains in giant molecular clouds can be used to probe the physical properties, such as density, temperature and emissivity in star-forming regions. We present the Submillimetre Common-User Bolometer Array (SCUBA-2) shared-risk observations at 450 and 850 μm of the Orion A molecular cloud complex taken at the James Clerk Maxwell Telescope (JCMT). Previous studies showed that molecular emission lines can contribute significantly to the measured fluxes in those continuum bands. We use the Heterodyne Array Receiver Programme 12CO J = 3-2 integrated intensity map for Orion A in order to evaluate the molecular line contamination and its effects on the SCUBA-2 maps. With the corrected fluxes, we have obtained a new spectral index α map for the thermal emission of dust in the well-known integral-shaped filament. Furthermore, we compare a sample of 33 sources, selected over the Orion A molecular cloud complex for their high 12CO J = 3-2 line contamination, to 27 previously identified clumps in OMC 4. This allows us to quantify the effect of line contamination on the ratio of 850-450 μm flux densities and how it modifies the deduced spectral index of emissivity β for the dust grains. We also show that at least one Spitzer-identified protostellar core in OMC 5 has a 12CO J = 3-2 contamination level of 16 per cent. Furthermore, we find the strongest contamination level (44 per cent) towards a young star with disc near OMC 2. This work is part of the JCMT Gould Belt Legacy Survey.

  9. The JCMT Gould Belt Survey: evidence for radiative heating and contamination in the W40 complex

    NASA Astrophysics Data System (ADS)

    Rumble, D.; Hatchell, J.; Pattle, K.; Kirk, H.; Wilson, T.; Buckle, J.; Berry, D. S.; Broekhoven-Fiene, H.; Currie, M. J.; Fich, M.; Jenness, T.; Johnstone, D.; Mottram, J. C.; Nutter, D.; Pineda, J. E.; Quinn, C.; Salji, C.; Tisi, S.; Walker-Smith, S.; di Francesco, J.; Hogerheijde, M. R.; Ward-Thompson, D.; Bastien, P.; Bresnahan, D.; Butner, H.; Chen, M.; Chrysostomou, A.; Coude, S.; Davis, C. J.; Drabek-Maunder, E.; Duarte-Cabral, A.; Fiege, J.; Friberg, P.; Friesen, R.; Fuller, G. A.; Graves, S.; Greaves, J.; Gregson, J.; Holland, W.; Joncas, G.; Kirk, J. M.; Knee, L. B. G.; Mairs, S.; Marsh, K.; Matthews, B. C.; Moriarty-Schieven, G.; Mowat, C.; Rawlings, J.; Richer, J.; Robertson, D.; Rosolowsky, E.; Sadavoy, S.; Thomas, H.; Tothill, N.; Viti, S.; White, G. J.; Wouterloot, J.; Yates, J.; Zhu, M.

    2016-08-01

    We present SCUBA-2 450 μm and 850 μm observations of the W40 complex in the Serpens-Aquila region as part of the James Clerk Maxwell Telescope (JCMT) Gould Belt Survey (GBS) of nearby star-forming regions. We investigate radiative heating by constructing temperature maps from the ratio of SCUBA-2 fluxes using a fixed dust opacity spectral index, β = 1.8, and a beam convolution kernel to achieve a common 14.8 arcsec resolution. We identify 82 clumps ranging between 10 and 36 K with a mean temperature of 20 ± 3 K. Clump temperature is strongly correlated with proximity to the external OB association and there is no evidence that the embedded protostars significantly heat the dust. We identify 31 clumps that have cores with densities greater than 105cm-3. 13 of these cores contain embedded Class 0/I protostars. Many cores are associated with bright-rimmed clouds seen in Herschel 70 μm images. From JCMT HARP observations of the 12CO 3-2 line, we find contamination of the 850 μm band of up to 20 per cent. We investigate the free-free contribution to SCUBA-2 bands from large-scale and ultracompact H II regions using archival VLA data and find the contribution is limited to individual stars, accounting for 9 per cent of flux per beam at 450 μm or 12 per cent at 850 μm in these cases. We conclude that radiative heating has potentially influenced the formation of stars in the Dust Arc sub-region, favouring Jeans stable clouds in the warm east and fragmentation in the cool west.

  10. The Economy of Shark Conservation in the Northeast Pacific: The Role of Ecotourism and Citizen Science.

    PubMed

    Mieras, Peter A; Harvey-Clark, Chris; Bear, Michael; Hodgin, Gina; Hodgin, Boone

    Historically sharks have been seen either as a source of income through harvesting, or as a nuisance and danger. The economic value of sharks has traditionally been measured as the total value of sharks caught for liver oil, fins, or meat for consumption. Sharks have also been killed to near extinction in cases where they were seen as a threat to fisheries on other species. This is illustrated by the mass extermination of Basking Sharks (Cetorhinus maximus) in British Columbia. They were seen as a nuisance to fishermen as they got entangled in gill nets during the salmon fishing season. However with the development of the SCUBA diving industry, and ecotourism in general, increased awareness of the role sharks play in marine ecosystems has resulted in changes in how they are perceived and utilized. Despite an ongoing harvest of sharks such as the North Pacific Spiny Dogfish (Squalus suckleyi), sharks now generate economic value through SCUBA diving enthusiasts who travel the globe to see, swim with, and photograph them. The use of digital cameras and other digital media has brought sharks into households around the world and increased awareness of the conservation issues facing many species. This renewed appreciation has led to a better understanding of sharks by the public, resulting in advocates calling for better protections and conservation. In particular, a growing part of the SCUBA diving community wants to contribute to conservation and research projects, which has led to participation in citizen science projects. These projects provide scientific data but also gain ground as ecotourism activities, thus adding to both economic value of tourism and conservation efforts. © 2017 Elsevier Ltd All rights reserved.

  11. Submillimetre observations of WISE-selected high-redshift, luminous, dusty galaxies

    NASA Astrophysics Data System (ADS)

    Jones, Suzy F.; Blain, Andrew W.; Stern, Daniel; Assef, Roberto J.; Bridge, Carrie R.; Eisenhardt, Peter; Petty, Sara; Wu, Jingwen; Tsai, Chao-Wei; Cutri, Roc; Wright, Edward L.; Yan, Lin

    2014-09-01

    We present SCUBA-2 (Submillimetre Common-User Bolometer Array) 850 μm submillimetre (submm) observations of the fields of 10 dusty, luminous galaxies at z ˜ 1.7-4.6, detected at 12 and/or 22 μm by the Wide-field Infrared Survey Explorer (WISE) all-sky survey, but faint or undetected at 3.4 and 4.6 μm; dubbed hot, dust-obscured galaxies (Hot DOGs). The six detected targets all have total infrared luminosities greater than 1013 L⊙, with one greater than 1014 L⊙. Their spectral energy distributions (SEDs) are very blue from mid-infrared to submm wavelengths and not well fitted by standard active galactic nuclei (AGN) SED templates, without adding extra dust extinction to fit the WISE 3.4 and 4.6 μm data. The SCUBA-2 850 μm observations confirm that the Hot DOGs have less cold and/or more warm dust emission than standard AGN templates, and limit an underlying extended spiral or ULIRG-type galaxy to contribute less than about 2 or 55 per cent of the typical total Hot DOG IR luminosity, respectively. The two most distant and luminous targets have similar observed submm to mid-infrared ratios to the rest, and thus appear to have even hotter SEDs. The number of serendipitous submm galaxies detected in the 1.5-arcmin-radius SCUBA-2 850 μm maps indicates there is a significant overdensity of serendipitous sources around Hot DOGs. These submm observations confirm that the WISE-selected ultraluminous galaxies have very blue mid-infrared to submm SEDs, suggesting that they contain very powerful AGN, and are apparently located in unusual arcmin-scale overdensities of very luminous dusty galaxies.

  12. Gender and Decompression Sickness: A Critical Review and Analysis

    NASA Technical Reports Server (NTRS)

    2004-01-01

    The author addressed the following questions: are women at greater risk of decompression sickness and venous gas emboli at certain times in their reproductive cycle, is risk modified by the use of birth control pills (BCP), and is there a difference in overall risk between men and women under the same decompression dose? The summary considers information from the few abstracts and reports that were available. Except for the observation of more Type II DCS in women, particularly in women who fly after diving, there was no compelling evidence of a difference in DCS risk between men and women SCUBA divers. Many women that presented with DCS symptoms seemed to be in or near menses, with statistically fewer cases reported as time increased from menses. There was no compelling evidence that the use of BCP in SCUBA divers increases the risk of DCS. There were insufficient data about VGE from SCUBA diving to make any conclusion about the incidence of VGE and gender. In contrast, there were ample data about VGE from research in altitude chambers. Women produced less VGE and less Grade IV VGE compared to men under the same decompression dose, certainly when resting oxygen prebreathe (PB) was performed prior to ascent to altitude. Dual-cycle ergometry exercise during PB tends to reduce the differences in VGE between men and women. There was no compelling evidence that the risk of altitude DCS was different between men and women. However, a large number of DCS cases were associated with menses, and the use of BCP did seem to put women at a slightly greater risk than those that did not use BCP. There were substantial observations that women comprised a larger number of difficult cases that required complicated medical management.

  13. Sub-millimetre properties of massive star-forming galaxies at z ~ 2 in SHADES/SXDF

    NASA Astrophysics Data System (ADS)

    Takagi, T.; Mortier, A. M. J.; Shimasaku, K.; Coppin, K.; Pope, A.; Ivison, R. J.; Hanami, H.; Serjeant, S.; Dunlop, J. S.

    2007-05-01

    We study the submillimetre (submm) properties of the following NIR-selected massive galaxies at high redshifts: BzK-selected star-forming galaxies (BzKs), distant red galaxies (DRGs) and extremely red objects (EROs). We used the SCUBA HAlf Degree Extragalactic Survey (SHADES), the largest uniform submm survey to date. We detected 6 NIR-selected galaxies in our SCUBA map. Four submm-detected galaxies out of six are found to be detected both at 24 micron and in radio (1.4 GHz), and therefore confirmed as genuine submm-bright galaxies. We identify two submm-bright NIR-selected galaxies are the BzK-DRG-ERO overlapping population. Although this overlapping population is rare, about 12% of this population could be submm galaxies. With a stacking analysis, we detected the 850-micron flux of submm-faint BzKs and EROs in our SCUBA maps. While the contribution from BzKs at z˜2 to submm background is about 10 - 15 % and similar to that from EROs typically at z˜1, BzKs have a higher fraction (˜30%) of flux in resolved sources than EROs do. Therefore, submm flux of BzKs seems to be biased high. From the SED fitting using an evolutionary model of starbursts with radiative transfer, submm-bright NIR-selected galaxies, mostly BzKs, are found to have the stellar mass of >5x1010M[sun] with the bolometric luminosity of >3x1012L[sun]. On the other hand, an average SED of submm-faint BzKs indicates the typical stellar mass of <6x1010M[sun] and therefore less massive.

  14. Preconditioning to Reduce Decompression Stress in Scuba Divers.

    PubMed

    Germonpré, Peter; Balestra, Costantino

    2017-02-01

    Using ultrasound imaging, vascular gas emboli (VGE) are observed after asymptomatic scuba dives and are considered a key element in the potential development of decompression sickness (DCS). Diving is also accompanied with vascular dysfunction, as measured by flow-mediated dilation (FMD). Previous studies showed significant intersubject variability to VGE for the same diving exposure and demonstrated that VGE can be reduced with even a single pre-dive intervention. Several preconditioning methods have been reported recently, seemingly acting either on VGE quantity or on endothelial inflammatory markers. Nine male divers who consistently showed VGE postdive performed a standardized deep pool dive (33 m/108 ft, 20 min in 33°C water temperature) to investigate the effect of three different preconditioning interventions: heat exposure (a 30-min session of dry infrared sauna), whole-body vibration (a 30-min session on a vibration mattress), and dark chocolate ingestion (30 g of chocolate containing 86% cocoa). Dives were made one day per week and interventions were administered in a randomized order. These interventions were shown to selectively reduce VGE, FMD, or both compared to control dives. Vibration had an effect on VGE (39.54%, SEM 16.3%) but not on FMD postdive. Sauna had effects on both parameters (VGE: 26.64%, SEM 10.4%; FMD: 102.7%, SEM 2.1%), whereas chocolate only improved FMD (102.5%, SEM 1.7%). This experiment, which had the same subjects perform all control and preconditioning dives in wet but completely standardized diving conditions, demonstrates that endothelial dysfunction appears to not be solely related to VGE.Germonpré P, Balestra C. Preconditioning to reduce decompression stress in scuba divers. Aerosp Med Hum Perform. 2017; 88(2):114-120.

  15. The JCMT Gould Belt Survey: A First Look at SCUBA-2 Observations of the Lupus I Molecular Cloud

    NASA Astrophysics Data System (ADS)

    Mowat, C.; Hatchell, J.; Rumble, D.; Kirk, H.; Buckle, J.; Berry, D. S.; Broekhoven-Fiene, H.; Currie, M. J.; Jenness, T.; Johnstone, D.; Mottram, J. C.; Pattle, K.; Tisi, S.; Di Francesco, J.; Hogerheijde, M. R.; Ward-Thompson, D.; Bastien, P.; Bresnahan, D.; Butner, H.; Chen, M.; Chrysostomou, A.; Coudé, S.; Davis, C. J.; Drabek-Maunder, E.; Duarte-Cabral, A.; Fich, M.; Fiege, J.; Friberg, P.; Friesen, R.; Fuller, G. A.; Graves, S.; Greaves, J.; Holland, W.; Joncas, G.; Kirk, J. M.; Knee, L. B. G.; Mairs, S.; Marsh, K.; Matthews, B. C.; Moriarty-Schieven, G.; Rawlings, J.; Retter, B.; Richer, J.; Robertson, D.; Rosolowsky, E.; Sadavoy, S.; Thomas, H.; Tothill, N.; Viti, S.; White, G. J.; Wouterloot, J.; Yates, J.; Zhu, M.

    2017-05-01

    This paper presents observations of the Lupus I molecular cloud at 450 and 850 μm with Submillimetre Common User Bolometer Array (SCUBA-2) as part of the James Clerk Maxwell Telescope Gould Belt Survey (JCMT GBS). Nine compact sources, assumed to be the discs of young stellar objects (YSOs), 12 extended protostellar, pre-stellar and starless cores, and one isolated, low-luminosity protostar, are detected in the region. Spectral energy distributions, including submillimetre fluxes, are produced for 15 YSOs, and each is fitted with the models of Robitaille et al. The proportion of Class 0/I protostars is higher than that seen in other Gould Belt regions such as Ophiuchus and Serpens. Circumstellar disc masses are calculated for more evolved sources, while protostellar envelope masses are calculated for protostars. Up to four very low luminosity objects are found; a large fraction when compared to other Spitzer c2d regions. One YSO has a disc mass greater than the minimum mass solar nebula. 12 starless/protostellar cores are detected by SCUBA-2 and their masses are calculated. The stability of these cores is examined using both the thermal Jeans mass and a turbulent virial mass when possible. Two cores in Lupus I are super-Jeans and contain no known YSOs. One of these cores has a virial parameter of 1.1 ± 0.4, and could therefore be pre-stellar. The high ratio of Class 0/I to Class III YSOs (1:1), and the presence of a pre-stellar core candidate, provides support for the hypothesis that a shock recently triggered star formation in Lupus I.

  16. VizieR Online Data Catalog: S2CLS: multiwavelength counterparts to SMGs (Chen+, 2016)

    NASA Astrophysics Data System (ADS)

    Chen, C.-C.; Smail, I.; Ivison, R. J.; Arumugam, V.; Almaini, O.; Conselice, C. J.; Geach, J. E.; Hartley, W. G.; Ma, C.-J.; Mortlock, A.; Simpson, C.; Simpson, J. M.; Swinbank, A. M.; Aretxaga, I.; Blain, A.; Chapman, S. C.; Dunlop, J. S.; Farrah, D.; Halpern, M.; Michalowski, M. J.; van der Werf, P.; Wilkinson, A.; Zavala, J. A.

    2016-05-01

    The SCUBA-2 data at 850um in the UDS field were taken as part of the SCUBA-2 Cosmology Legacy Survey (S2CLS). The full data reduction steps are described fully in J. E. Geach et al. (2016, in preparation). In total we detect 1088 submillimeter sources at >=3.5σ within the region where rms noise is <=1.3mJy/beam. We define a main sample of 716 submillimeter sources that have >=4.0σ, for which we expect a false detection rate of ~1% based on simulations and source extractions on negative signals. We also define a supplementary sample of 372 submillimeter sources that are detected at 3.5-4.0σ and have a false detection rate of ~10%. In this paper, we provide counterpart candidates for both main and supplementary samples; however, the scientific analyses were performed on the main sample. We have carried out ALMA follow-up observations at 870um on 30 of the brighter SCUBA-2 sources in a Cycle 1 project 2012.1.00090.S (Simpson et al. 2015ApJ...807..128S, 2015ApJ...799...81S). The K-band-based multiwavelength photometry adopted in this paper is based on the UDS data release 8 (DR8) of the UKIRT Infrared Deep Sky Survey (UKIDSS; Lawrence et al. 2007, see II/319). The VLA radio observations at 1.4GHz (20cm) were carried out by the project UDS20 (V. Arumugam et al. 2016, in preparation), which comprises a mosaic of 14 pointings covering a total area of ~1.3deg2 centered on the UDS. The ~1 square degree UDS field contains a rich set of ancillary data (see section 2 for further details). (2 data files).

  17. The SCUBA-2 850 μm Follow-up of WISE-selected, Luminous Dust-obscured Quasars

    NASA Astrophysics Data System (ADS)

    Fan, Lulu; Jones, Suzy F.; Han, Yunkun; Knudsen, Kirsten K.

    2017-12-01

    Hot dust-obscured galaxies (Hot DOGs) are a new population recently discovered in the Wide-field Infrared Survey Explorer All-Sky survey. Multiwavelength follow-up observations suggest that they are luminous, dust-obscured quasars at high redshift. Here we present the JCMT SCUBA-2 850 μm follow-up observations of 10 Hot DOGs. Four out of ten Hot DOGs have been detected at >3σ level. Based on the IR SED decomposition approach, we derive the IR luminosities of AGN torus and cold dust components. Hot DOGs in our sample are extremely luminous with most of them having {L}{IR}{tot}> {10}14 {L}⊙ . The torus emissions dominate the total IR energy output. However, the cold dust contribution is still non-negligible, with the fraction of the cold dust contribution to the total IR luminosity (˜8%-24%) being dependent on the choice of torus model. The derived cold dust temperatures in Hot DOGs are comparable to those in UV bright quasars with similar IR luminosity, but much higher than those in SMGs. Higher dust temperatures in Hot DOGs may be due to the more intense radiation field caused by intense starburst and obscured AGN activities. Fourteen and five submillimeter serendipitous sources in the 10 SCUBA-2 fields around Hot DOGs have been detected at >3σ and >3.5σ levels, respectively. By estimating their cumulative number counts, we confirm the previous argument that Hot DOGs lie in dense environments. Our results support the scenario in which Hot DOGs are luminous, dust-obscured quasars lying in dense environments, and being in the transition phase between extreme starburst and UV-bright quasars.

  18. Portable Medical Diagnosis Instrument

    NASA Technical Reports Server (NTRS)

    Coleman, Matthew A. (Inventor); Straume, Tore (Inventor); Loftus, David J. (Inventor); Li, Jing (Inventor); Singh, Anup K. (Inventor); Davis, Cristina E. (Inventor)

    2017-01-01

    A system that integrates several technologies into a single, portable medical diagnostic apparatus for analyzing a sample body fluid (liquid and/or gas): (1) a mechanism to capture airborne microdroplets and to separate the body fluid into a first fluid component (primarily gas) and a second fluid component (primarily liquid); (2) a volatilizer to convert a portion of the second fluid component into a third fluid component that is primarily a gas; (3) a functionalized nanostructure (NS) array configured to receive, identify, and estimate concentration of at least one constituent in the first and/or third fluid components; (4) a miniaturized differential mobility spectrometer (DMS) module; and (5) a biomarker sensor, to detect volatile and non-volatile molecules in a sample fluid, which may contain one or more components of blood, breath, perspiration, saliva, and urine.

  19. 20 CFR 701.301 - Definitions and use of terms.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... employment, including: (A) Any longshore worker or other person engaged in longshoring operations; (B) Any... operation (meaning any recreational activity, including but not limited to scuba diving, commercial rafting... renting, leasing or chartering equipment to another for the latter's pleasure), restaurant, museum or...

  20. Learning on the Big Bay

    ERIC Educational Resources Information Center

    Philp, Michael J.

    1978-01-01

    Anne Arundel Community College uses the Chesapeake Bay for a flexible ocean engineering technology program which includes mechanical, electrical, and environmental options for transfer and/or vocational students, and adult education programs covering such subjects as sailing, Bay history, boat building, scuba-diving, and marine biology. (RT)

  1. Maintenance Manual for the Automated Airdrop Information Retrieval System; Human Factors Database

    DTIC Science & Technology

    1994-09-01

    Sensorimotor Abilities Loss of Cognitive/Perceptual Abilities Treatment drug therapy physical therapy cognitive therapy biofeedback therapy 63 9...Device (AOD) Oxygen System oxygen mask oxygen hose oxygen cylinders on/off valve prebreather Floatation Devices life preserver Scuba Gear Ankle Braces

  2. A red orange extract modulates the vascular response to a recreational dive: a pilot study on the effect of anthocyanins on the physiological consequences of scuba diving.

    PubMed

    Balestra, C; Cimino, F; Theunissen, S; Snoeck, T; Provyn, S; Canali, R; Bonina, A; Virgili, F

    2016-09-01

    Nutritional antioxidants have been proposed as an expedient strategy to counter the potentially deleterious effects of scuba diving on endothelial function, flow-mediated dilation (FMD) and heart function. Sixteen volunteers performing a single standard dive (20 min at 33 m) according to US Navy diving procedures were randomly assigned to two groups: one was administered with two doses of 200 mg of an anthocyanins (AC)-rich extract from red oranges, 12 and 4 h before diving. Anthocyanins supplementation significantly modulated the effects of diving on haematocrit, body water distribution and FMD. AC administration significantly reduces the potentially harmful endothelial effects of a recreational single dive. The lack of any significant effect on the most common markers of plasma antioxidant capacity suggests that the mechanism underlying this protective activity is independent of the putative antioxidant effect of AC and possibly involves cellular signalling modulation of the response to high oxygen.

  3. Severe capillary leak syndrome after inner ear decompression sickness in a recreational scuba diver.

    PubMed

    Gempp, Emmanuel; Lacroix, Guillaume; Cournac, Jean-Marie; Louge, Pierre

    2013-07-01

    Post-decompression shock with plasma volume deficit is a very rare event that has been observed under extreme conditions of hypobaric and hyperbaric exposure in aviators and professional divers. We report a case of severe hypovolemic shock due to extravasation of plasma in a recreational scuba diver presenting with inner ear decompression sickness. Impaired endothelial function can lead to capillary leak with hemoconcentration and hypotension in severe cases. This report suggests that decompression-induced circulating bubbles may have triggered the endothelial damage, activating the classic inflammatory pathway of increased vascular permeability. This observation highlights the need for an accurate diagnosis of this potentially life-threatening condition at the initial presentation in the Emergency Department after a diving-related injury. An elevated hematocrit in a diver should raise the suspicion for the potential development of capillary leak syndrome requiring specific treatment using albumin infusion as primary fluid replacement. Copyright © 2013 Elsevier Inc. All rights reserved.

  4. Humidity of anaesthetic gases with respect to low flow anaesthesia.

    PubMed

    Kleemann, P P

    1994-08-01

    It has been demonstrated in an experimental study in swine using the scanning electron microscope that a rebreathing technique utilising minimal fresh gas flowrates significantly improves climatization of anaesthetic gases. Consequently, effects of various anaesthetic techniques on airway climate must be assessed, which covers the need for suitable measuring devices. Basic principles and methods of humidity measurement in flowing anaesthetic gases include gravimetric hygrometry, dew point hygrometry, wet-dry bulb psychrometry, mass spectrometry, spectroscopic hygrometry and electrical hygrometry. A custom-made apparatus for continuous measurement of humidity and temperature in the inspired and expired gas mixtures of a breathing circuit (separated by a valve system, integrated between the endotracheal tube and the Y-piece) is described. Comparative evaluation of this apparatus and the psychrometer was carried out. It could be demonstrated that the apparatus, measuring with capacitive humidity sensors, is more suitable for prolonged use under clinical conditions than the psychrometer. In the second part of the study, climatization of anaesthetic gases under clinical conditions was investigated using fresh gas flowrates of 0.6, 1.5, 3.0 and 6.0 l/min. In the inspiratory limb of the circuit an absolute humidity of 21.3 mg H2O/l and a temperature of 31.5 degrees C were obtained after 120 minutes of minimal flow. Humidity and temperature of inspired air obtained with fresh gas flowrates of 6.0 and 3.0 l/min were found to be inadequate for prolonged anaesthesia. Reducing the fresh gas flow to 1.5 l/min increases heat and moisture content in the respired gases, but conditions are still inadequate for prolonged anaesthesia. Sufficient moisture (> or 20 mg H2O/l) and temperature are obtained under minimal flow conditions after one hour.

  5. Astronauts McMonagle and Brown float in one-man life rafts during training

    NASA Technical Reports Server (NTRS)

    1994-01-01

    In separate life rafts, astronauts Donald R. McMonagle (right), STS-66 mission commander, and Curtis L. Brown, STS-66 pilot, are assisted by several SCUBA-equipped divers during an emergency bailout training exercise in JSC's Weightless Environment Training Facility (WETF).

  6. Extreme Millimeter/Sub-millimeter and Radio Flares from V404 Cyg (GS 2023+338)

    NASA Astrophysics Data System (ADS)

    Tetarenko, A.; Sivakoff, G. R.; Young, Ken; Wouterloot, J. G. A.; Miller-Jones, J. C.

    2015-06-01

    We report follow up radio and mm/sub-mm observations (ATel #7671) of the current outburst of the black hole X-ray binary, V404 Cyg, with the VLA, Submillimeter Array (SMA), and James Clerk Maxwell Telescope SCUBA-2 (JCMT).

  7. De Anza Summer College "By the Sea"; Evaluation Report, 1974.

    ERIC Educational Resources Information Center

    College of the Redwoods, Eureka, CA.

    This report describes an off-campus alternative to traditional summer school sponsored by De Anza College and College of the Redwoods (California). Three twelve-day, concentrated summer programs, called "Action Learning Modules", utilized an interdisciplinary approach. The first module combined oceanography, marine biology, and scuba diving. A…

  8. 75 FR 43150 - Marine Mammals; File Nos. 10018, 13846, 14451, 14585, 14599, 14122, 14296, and 14353

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-23

    ... of sloughed skin, photogrammetry, biopsy sampling, playback experiments, and/or suction- cup and... to individuals; (6) attachment of suction cup tags; (7) SCUBA observations; and (8) opportunistic.... Research will include vessel-based approaches: (1) to humpback whales for biological sampling, suction cup...

  9. Visual observation of fishes and aquatic habitat [Chapter 17

    Treesearch

    Russell F. Thurow; C. Andrew Dolloff; J. Ellen Marsden

    2012-01-01

    Whether accomplished above the water surface or performed underwater by snorkel, scuba, or hookah divers or remotely operated vehicles (ROVs); direct observation techniques are among the most effective means for obtaining accurate and often unique information on aquatic organisms in their natural surroundings. Many types of studies incorporate direct observation...

  10. Visual resource management of the sea

    Treesearch

    Louis V. Mills Jr.

    1979-01-01

    The scenic quality of the marine environment has become an important concern for the design and planning professions. Increased public use of the underwater environment has resulted from technological advancements in SCUBA, recreational submarines and through development of under-water restaurants and parks. This paper presents an approach to an underwater visual...

  11. 43 CFR 423.36 - Swimming.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Swimming. (a) You may swim, wade, snorkel, scuba dive, raft, or tube at your own risk in Reclamation waters... sites, and designated mooring areas; or (5) As otherwise delineated by signs or other markers. (b) You... Guard guidelines when engaging in any underwater activities. (c) You must not dive, jump, or swing from...

  12. Lack of Feeding Progression in a Preterm Infant: A Case Study

    PubMed Central

    White-Traut, Rosemary; Shapiro, Nicole; Healy-Baker, Elissa; Menchavez, Lina; Rankin, Kristin; Medoff-Cooper, Barbara

    2012-01-01

    Purpose To present the case of a premature infant who displayed immature feeding progression due to nasal occlusion. Subjects Two male preterm infants 33 weeks gestational age at birth from a larger randomized trial. Design Comparative case study. Methods Using a prospective design, feeding assessments were conducted weekly from initiation of oral feeding until hospital discharge. Sucking organization was measured using the Medoff-Cooper Nutritive Sucking Apparatus (M-CNSA) which measured negative sucking pressure generated during oral feedings. Oral and nasogastric (NG) intake and vital signs were recorded. Results At 35 weeks, Infant A demonstrated an immature feeding pattern with NG feedings prevailing over oral feedings. When attempting to feed orally, Infant A exhibited labored breathing and an erratic sucking pattern. During the third weekly feeding evaluation, nasal occlusion was discovered, the NG tube was discontinued, and neosynephrene and humidified air were administered. Following treatment, Infant A’s sucking pattern normalized and the infant maintained complete oral feeding. Infant B demonstrated normal feeding progression. Conclusion Nasal occlusion prevented Infant A from achieving successful oral feeding. The M-CNSA has the ability to help clinicians detect inconsistencies in the breath-suck-swallow feeding patterns of infants and objectively measures patterns of nutritive sucking. The M-CNSA has the potential to influence clinical decision making and identify the need for intervention. PMID:23722488

  13. Experimental Dynamic Analysis of a Breathing Cracked Rotor

    NASA Astrophysics Data System (ADS)

    Guo, Chao-Zhong; Yan, Ji-Hong; Bergman, Lawrence A.

    2017-09-01

    Crack fault diagnostics plays a critical role for rotating machinery in the traditional and Industry 4.0 factory. In this paper, an experiment is set up to study the dynamic response of a rotor with a breathing crack as it passes through its 1/2, 1/3, 1/4 and 1/5 subcritical speeds. A cracked shaft is made by applying fatigue loads through a three-point bending apparatus and then placed in a rotor testbed. The vibration signals of the testbed during the coasting-up process are collected. Whirl orbit evolution at these subcritical speed zones is analyzed. The Fourier spectra obtained by FFT are used to investigate the internal frequencies corresponding to the typical orbit characteristics. The results show that the appearance of the inner loops and orientation change of whirl orbits in the experiment are agreed well with the theoretical results obtained previously. The presence of higher frequencies 2X, 3X, 4X and 5X in Fourier spectra reveals the causes of subharmonic resonances at these subcritical speed zones. The experimental investigation is more systematic and thorough than previously reported in the literature. The unique dynamic behavior of the orbits and frequency spectra are feasible features for practical crack diagnosis. This paper provides a critical technology support for the self-aware health management of rotating machinery in the Industry 4.0 factory.

  14. [The "Mining Rescue System and Mine Fires" Working Group. Tasks, results, future activities].

    PubMed

    Coenders, A

    1983-01-01

    The president of the working party presents details of its principal tasks in the past and in the present time. These can be summed up in a study of the problems mentioned below and the subsequent elaboration of recommendations for the benefit of the governments, guidelines, information reports and research proposals. The principal problems that were or are still under study are: --prevention of fires: shaft equipment, hydraulic fluids, belt conveyors, . . .; --detection of mine fires and spontaneous combustion; --fighting of mine fires: shaft fires, construction of stoppings, openings and recovering of fire zones, . . .; --coordination and rescue equipment: escape and rescue breathing apparatus, flameproof clothing, rescue of trapped miners; --stabilization of ventilation in the event of fire, . . . The speaker stresses the importance of the information exchange and the atmosphere of fellowship and solidarity that prevails in the working party.

  15. Military Curricula for Vocational & Technical Education. Diver Second Class, 15-3.

    ERIC Educational Resources Information Center

    Ohio State Univ., Columbus. National Center for Research in Vocational Education.

    This curriculum outline, student guide, and instructor guide for a secondary-postsecondary-level course in scuba diving (diver second class) is one of a number of military-developed curriculum packages selected for adaptation to vocational instruction and curriculum development in a civilian setting. Purpose stated for the 425-hour course is to…

  16. 78 FR 2957 - Notice of Applicability of Special Use Permit Requirements to Certain Categories of Activities...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-15

    ... MONITOR, NOAA has determined that enhancing recreational diving access to the wreck is a priority. NOAA... diving near the USS MONITOR; and (2) fireworks displays. The remaining two special use permit categories..., etc. Specific examples of such events involve the promotion of SCUBA diving; an annual underwater...

  17. STS-104 Preflight Emergency Egress Bailout Training at the NBL

    NASA Image and Video Library

    2001-01-03

    JSC2001-00003 (January 2001) --- Astronaut Janet L. Kavandi, STS-104 mission specialist, is assisted by SCUBA-equipped divers during an emergency bailout training session in the Neutral Buoyancy Laboratory (NBL) near Johnson Space Center (JSC). Kavandi will join four other astronauts for a June mission with the International Space Station (ISS).

  18. The Effect of Molecular Contamination on the Emissivity Spectral Index in Orion A

    NASA Astrophysics Data System (ADS)

    Coudé, Simon; Bastien, Pierre; Drabek, Emily; Johnstone, Doug; Hatchell, Jennifer

    2013-07-01

    The emissivity spectral index is a critical component in the study of the physical properties of dust grains in cold and optically thin interstellar star forming regions. Since submillimeter astronomy is an ideal tool to measure the thermal emission of those dust grains, it can be used to characterize this important parameter. We present the SCUBA-2 shared risks observations at 450 μm and 850 μm of the Orion A molecular cloud obtained at the James-Clerk-Maxwell telescope. Previous studies showed that molecular emission lines can also contribute significantly to the measured fluxes in those continuum bands. We use HARP 12CO 3-2 maps to evaluate the total molecular line contamination in the SCUBA-2 maps and its effect on the determination of the spectral index in highly contaminated areas. With the corrected fluxes, we have obtained new spectral index maps for different regions of the well-known integral-shaped filament. This work is part of an ongoing effort to characterize the properties of star forming regions in the Gould belt with the new instruments available at the JCMT.

  19. A Full Virial Analysis of the Prestellar Cores in the Ophiuchus Molecular Cloud

    NASA Astrophysics Data System (ADS)

    Pattle, Kate; Ward-Thompson, Derek

    We use SCUBA-2, HARP C18O J= 3 -> 2, Herschel and IRAM N2H+ J= 1 -> 0 observations of the Ophiuchus molecular cloud to identify and characterise the properties of the starless cores in the region. The SCUBA-2, HARP and Herschel data were taken as part of the JCMT and Herschel Gould Belt Surveys. We determine masses and temperatures and perform a full virial analysis on our cores, and find that our cores are all either bound or virialised, with gravitational energy and external pressure energy on average of similar importance in confining the cores. There is wide variation from region to region, with cores in the region influenced by B stars (Oph A) being substantially gravitationally bound, and cores in the most quiescent region (Oph C) being pressure-confined. We observe dissipation of turbulence in all our cores, and find that this dissipation is more effective in regions which do not contain outflow-driving protostars. Full details of this analysis are presented by Pattle et al. (2015).

  20. Distribution, abundance, and habitat associations of a large bivalve (Panopea generosa) in a eutrophic, fjord estuary

    USGS Publications Warehouse

    Mcdonald, P. Sean; Essington, Timothy E.; Davis, Jonathan P.; Galloway, Aaron W.E.; Stevick, Bethany C.; Jensen, Gregory C.; VanBlaricom, Glenn R.; Armstrong, David A.

    2015-01-01

    Marine bivalves are important ecosystem constituents and frequently support valuable fisheries. In many nearshore areas, human disturbance—including declining habitat and water quality—can affect the distribution and abundance of bivalve populations, and complicate ecosystem and fishery management assessments. Infaunal bivalves, in particular, are frequently cryptic and difficult to detect; thus, assessing potential impacts on their populations requires suitable, scalable methods for estimating abundance and distribution. In this study, population size of a common benthic bivalve (the geoduck Panopea generosa) is estimated with a Bayesian habitat-based model fit to scuba and tethered camera data in Hood Canal, a fjord basin in Washington state. Densities declined more than two orders of magnitude along a north—south gradient, concomitant with patterns of deepwater dissolved oxygen, and intensity and duration of seasonal hypoxia. Across the basin, geoducks were most abundant in loose, unconsolidated, sand substrate. The current study demonstrates the utility of using scuba, tethered video, and habitat models to estimate the abundance and distribution of a large infaunal bivalve at a regional (385-km2) scale.

  1. Underwater research methods for study of nuclear bomb craters, Enewetak, Marshall Islands

    USGS Publications Warehouse

    Shinn, E.A.; Halley, R.B.; Kindinger, J.L.; Hudson, J.H.; Slate, R.A.

    1990-01-01

    Three craters, created by the explosion of nuclear fusion devices, were mapped, sampled, core drilled and excavated with airlifts at Enewetak Atoll in the Marshall Islands by using scuba and a research submersible. The craters studied were Mike, Oak, and Koa. Tests took place near sea level at the transition between lithified reef flat and unlithified lagoonal sediments, where water depth ranged from 1 to 4 m. Craters produced by the blasts ranged from 30 to 60 m in depth. The purpose of our study was to determine crater diameter and depth immediately after detonation. Observations of submerged roadways and testing structures and upturned crater rims similar to those characteristic of meteor impacts indicate that the initial, or transient, craters were smaller than their present size. At some later time, while the area was too radioactive for direct examination, the sides of the craters slumped owing to dewatering of under lying pulverized rock. Core drilling of crater margins with a diver-operated hydraulic coring device provided additional data. On the seaward margin of the atoll, opposite Mike, a large portion of the atoll rim approximately the size of a city block had slumped into the deep ocean, leaving a clean vertical rock section more than 400m high. An abundance of aggressive grey reef sharks displaying classic territorial behavior prevented use of scuba at the Mike slump site. The two-person submersible R.V. Delta provided protection and allowed observations down to 300 m. During the 6-week period of study, we made more than 300 scuba and 275 submersible dives. Mapping was with side scan sonar and continuous video sweeps supplemented by tape-recorded verbal descriptions made from within the submersible. A mini-ranger navigation system linked to the submersible allowed plotting of bottom features, depth and sediment type with spatial accuracy to within 2 m.

  2. Estimating the risk of a scuba diving fatality in Australia.

    PubMed

    Lippmann, John; Stevenson, Christopher; McD Taylor, David; Williams, Jo

    2016-12-01

    There are few data available on which to estimate the risk of death for Australian divers. This report estimates the risk of a scuba diving fatality for Australian residents, international tourists diving in Queensland, and clients of a large Victorian dive operator. Numerators for the estimates were obtained from the Divers Alert Network Asia-Pacific dive fatality database. Denominators were derived from three sources: Participation in Exercise, Recreation and Sport Surveys, 2001-2010 (Australian resident diving activity data); Tourism Research Australia surveys of international visitors to Queensland 2006-2014 and a dive operator in Victoria 2007-2014. Annual fatality rates (AFR) and 95% confidence intervals (95% CI) were calculated using an exact binomial test. Estimated AFRs were: 0.48 (0.37-0.59) deaths per 100,000 dives, or 8.73 (6.85-10.96) deaths per 100,000 divers for Australian residents; 0.12 (0.05-0.25) deaths per 100,000 dives, or 0.46 (0.20-0.91) deaths per 100,000 divers for international visitors to Queensland; and 1.64 (0.20-5.93) deaths per 100,000 dives for the dive operator in Victoria. On a per diver basis, Australian residents are estimated to be almost twenty times more likely to die whilst scuba diving than are international visitors to Queensland, or to lower than fourfold on a per dive basis. On a per dive basis, divers in Victoria are fourteen times more likely to die than are Queensland international tourists. Although some of the estimates are based on potentially unreliable denominator data extrapolated from surveys, the diving fatality rates in Australia appear to vary by State, being considerably lower in Queensland than in Victoria. These estimates are similar to or lower than comparable overseas estimates, although reliability of all such measurements varies with study size and accuracy of the data available.

  3. Spatial, temporal, and environmental dynamics of a multi-species epinephelid spawning aggregation in Pohnpei, Micronesia

    NASA Astrophysics Data System (ADS)

    Rhodes, K. L.; Nemeth, R. S.; Kadison, E.; Joseph, E.

    2014-09-01

    Long-term and short-term underwater visual censuses using SCUBA, technical Nitrox, and closed circuit rebreathers (CCR) were carried out in Pohnpei, Micronesia, to define spatial and temporal dynamics within a semi-protected multi-species epinephelid (fish) spawning aggregation (FSA) of brown-marbled grouper, Epinephelus fuscoguttatus, camouflage grouper, Epinephelus polyphekadion, and squaretail coralgrouper, Plectropomus areolatus. Results identified species-specific patterns of habitat use, abundance, residency, and dispersal of FSAs. Fish spawning aggregations formed and dispersed monthly within a 21-160-d period after winter solstice within adjacent yet distinct outer reef habitats. The reproductive season coincided with periods of seasonally low sub-surface seawater temperature. Peaks in density varied among species both within the calendar year and relative to the winter solstice. Significant long-term declines in FSA density were observed for all three species, suggesting population-level fishery-induced impacts, similar to those previously reported for E. polyphekadion. Differences in density estimates were also observed between dive gear, with a threefold difference in densities measured by CCR for E. polyphekadion versus SCUBA that suggest a disturbance effect from exhaled SCUBA bubbles for this species. CCR also allowed surveys to be conducted over a larger area in a single dive, thereby improving the potential to gauge actual abundance and density within FSAs. Based on these findings, a combination of long-term and intensive short-term monitoring strategies is recommended to fully characterize trends in seasonal abundance and habitat use for aggregating species at single or multi-species FSA sites. Inherent variations in the timing and distribution of species within FSA make fine-scale temporal management protocols less effective than blanket protective coverage of these species at (e.g., marine protected areas covering FSAs and adjacent migratory corridors) and away from (i.e., temporal sales and catch restrictions) FSA sites.

  4. Maintaining Adequate Carbon Dioxide Washout for an Advanced Extravehicular Mobility Unit

    NASA Technical Reports Server (NTRS)

    Chullen, Cinda; Navarro, Moses; Conger, Bruce; Korona, Adam; McMillin, Summer; Norcross, Jason; Swickrath, Mike

    2013-01-01

    Over the past several years, NASA has realized tremendous progress in technology development that is aimed at the production of an Advanced Extravehicular Mobility Unit (AEMU). Of the many functions provided by the spacesuit and portable life support subsystem within the AEMU, delivering breathing gas to the astronaut along with removing the carbon dioxide (CO2) remains one of the most important environmental functions that the AEMU can control. Carbon dioxide washout is the capability of the ventilation flow in the spacesuit helmet to provide low concentrations of CO2 to the crew member to meet breathing requirements. CO2 washout performance is a critical parameter needed to ensure proper and sufficient designs in a spacesuit and in vehicle applications such as sleep stations and hygiene compartments. Human testing to fully evaluate and validate CO2 washout performance is necessary but also expensive due to the levied safety requirements. Moreover, correlation of math models becomes challenging because of human variability and movement. To supplement human CO2 washout testing, a breathing capability will be integrated into a suited manikin test apparatus to provide a safe, lower cost, stable, easily modeled alternative to human testing. Additionally, this configuration provides NASA Johnson Space Center (JSC) the capability to evaluate CO2 washout under off-nominal conditions that would otherwise be unsafe for human testing or difficult due to fatigue of a test subject. Testing has been under way in-house at JSC and analysis has been initiated to evaluate whether the technology provides sufficient performance in ensuring that the CO2 is removed sufficiently and the ventilation flow is adequate for maintaining CO2 washout in the AEMU spacesuit helmet of the crew member during an extravehicular activity. This paper will review recent CO2 washout testing and analysis activities, testing planned in-house with a spacesuit simulator, and the associated analytical work along with insights from the medical aspect on the testing.

  5. An Annotated List of Marine Stations Suitable for Field Courses in Carbonate Geology and Tropical Marine Sciences.

    ERIC Educational Resources Information Center

    Kaplan, Eugene H.

    1980-01-01

    Listed are field stations in the Caribbean and Florida-Bahamas which are suitable for classes in field geology and tropical marine science. Each field station is described by listing the name of the institution, description of accommodations, library facilities, laboratory facilities, boats, classrooms, motor vehicles, study areas, scuba, and…

  6. [Crustaceans associated to macroalgae in Bajo Pepito, Isla Mujeres, Mexican Caribbean].

    PubMed

    Campos Vázquez, C

    2000-01-01

    Crustaceans associated with macroalgae were collected for one year by scuba diving in Bajo Pepito, Isla Mujeres, mexican Caribbean. A total of 148 organisms were found: three orders, 11 families, 18 genera and 19 species in nine types of associations. The order with highest abundance was Isopoda (112), followed by Amphipoda (20) and Decapoda (16).

  7. STS-59 crewmembers during WETF bailouts

    NASA Image and Video Library

    1993-12-02

    S93-50711 (22 Dec 1993) --- Astronauts Kevin P. Chilton (right), pilot, and Linda M. Godwin, payload commander, are assisted by SCUBA-equipped divers during emergency bailout training at the Johnson Space Center's (JSC) Weightless Environment Training Facility (WET-F). Godwin, Chilton and four other NASA astronauts are scheduled to fly aboard the Space Shuttle Endeavour next year.

  8. Firefighters' communication transceiver test plan

    NASA Astrophysics Data System (ADS)

    Wallace, R. J.

    1984-05-01

    The requirements for the operational testing of the firefighters communication transceiver were identified. The major concerns centered around the integrity and reliability of the firefighter/microphone interface. The major concern about the radio hardware was that it be intrinsically safe in hazardous atmospheres and that the system not interfere with the fit or facial seal of self-contained breathing apparatus (SCBA). The greatest concern for operational testing purposes as the reliability and clarity of the line of communication between the firefighter and those on the fireground with whom he must maintain contact. A desire to test any units developed in both training exercises and in real responses to hazardous material incidents was expressed. It is felt that a VOX-microphone built into the SCBA facemask gives the best performance. A voice-pickup product device which combines a bone conduction microphone and a speaker into a single ear mounted unit is examined.

  9. H2/O2 three-body rates at high temperatures

    NASA Technical Reports Server (NTRS)

    Marinelli, William J.; Kessler, William J.; Piper, Lawrence G.; Rawlins, W. Terry

    1990-01-01

    The extraction of thrust from air breathing hypersonic propulsion systems is critically dependent on the degree to which chemical equilibrium is reached in the combustion process. In the combustion of H2/Air mixtures, slow three-body chemical reactions involving H-atoms, O-atoms, and the OH radical play an important role in energy extraction. A first-generation high temperature and pressure flash-photolysis/laser-induced fluorescence reactor was designed and constructed to measure these important three-body rates. The system employs a high power excimer laser to produce these radicals via the photolysis of stable precursors. A novel two-photon laser-induced fluorescence technique is employed to detect H-atoms without optical thickness or O2 absorption problems. To demonstrate the feasibility of the technique the apparatus in the program is designed to perform preliminary measurements on the H + O2 + M reaction at temperatures from 300 to 835 K.

  10. Firefighters' communication transceiver test plan

    NASA Technical Reports Server (NTRS)

    Wallace, R. J.

    1984-01-01

    The requirements for the operational testing of the firefighters communication transceiver were identified. The major concerns centered around the integrity and reliability of the firefighter/microphone interface. The major concern about the radio hardware was that it be intrinsically safe in hazardous atmospheres and that the system not interfere with the fit or facial seal of self-contained breathing apparatus (SCBA). The greatest concern for operational testing purposes as the reliability and clarity of the line of communication between the firefighter and those on the fireground with whom he must maintain contact. A desire to test any units developed in both training exercises and in real responses to hazardous material incidents was expressed. It is felt that a VOX-microphone built into the SCBA facemask gives the best performance. A voice-pickup product device which combines a bone conduction microphone and a speaker into a single ear mounted unit is examined.

  11. LOx breathing system with gas permeable-liquid impermeable heat exchange and delivery hose

    DOEpatents

    Hall, M.N.

    1996-04-30

    Life support apparatus is composed of: a garment for completely enclosing a wearer and constructed for preventing passage of gas from the environment surrounding the garment; a portable receptacle holding a quantity of an oxygen-containing fluid in liquid state, the fluid being in a breathable gaseous state when at standard temperature and pressure; a fluid flow member secured within the garment and coupled to the receptacle for conducting the fluid in liquid state from the receptacle to the interior of the garment; and a fluid flow control device connected for causing fluid to flow from the receptacle to the fluid flow member at a rate determined by the breathable air requirement of the wearer, wherein fluid in liquid state is conducted into the interior of the garment at a rate to be vaporized and heated to a breathable temperature by body heat produced by the wearer. 6 figs.

  12. The preparation of calcium superoxide in a flowing gas stream and fluidized bed

    NASA Technical Reports Server (NTRS)

    Wood, P. C.; Ballou, E. V.; Spitze, L. A.; Wydeven, T.

    1980-01-01

    Superoxides can be used as sources of chemically stored oxygen in emergency breathing apparatus. The work reported here describes the use of a low-pressure nitrogen gas sweep through the reactant bed, for temperature control and water vapor removal. For a given set of gas temperature, bed thickness, and reaction time values, the highest purity calcium superoxide, Ca(O2)2, was obtained at the highest space velocity of the nitrogen gas sweep. The purity of the product was further increased by flow conditions that resulted in the fluidization of the reactant bed. However, scale-up of the low-pressure fluidized bed process was limited to the formation of agglomerates of reactant particles, which hindered thermal control by the flowing gas stream. A radiofrequency flow discharge inside the reaction chamber prevented agglomeration, presumably by dissipation of the static charges on the fluidized particles.

  13. Relationships between strength and endurance parameters and air depletion rates in professional firefighters

    PubMed Central

    Windisch, Stephanie; Seiberl, Wolfgang; Schwirtz, Ansgar; Hahn, Daniel

    2017-01-01

    The aim of this study was to quantify the physical demands of a simulated firefighting circuit and to establish the relationship between job performance and endurance and strength fitness measurements. On four separate days 41 professional firefighters (39 ± 9 yr, 179.6 ± 2.3 cm, 84.4 ± 9.2 kg, BMI 26.1 ± 2.8 kg/m2) performed treadmill testing, fitness testing (strength, balance and flexibility) and a simulated firefighting exercise. The firefighting exercise included ladder climbing (20 m), treadmill walking (200 m), pulling a wire rope hoist (15 times) and crawling an orientation section (50 m). Firefighting performance during the simulated exercise was evaluated by a simple time-strain-air depletion model (TSA) taking the sum of z-transformed parameters of time to finish the exercise, strain in terms of mean heart rate, and air depletion from the breathing apparatus. Multiple regression analysis based on the TSA-model served for the identification of the physiological determinants most relevant for professional firefighting. Three main factors with great influence on firefighting performance were identified (70.1% of total explained variance): VO2peak, the time firefighter exercised below their individual ventilatory threshold and mean breathing frequency. Based on the identified main factors influencing firefighting performance we recommend a periodic preventive health screening for incumbents to monitor peak VO2 and individual ventilatory threshold. PMID:28303944

  14. Physical interactions of hyperpolarized gas in the lung

    NASA Astrophysics Data System (ADS)

    Chen, Xiu-Hao Josette

    1999-09-01

    This thesis addresses key interactions of hyperpolarized (HP) gas within the biological environment of the lung using magnetic resonance imaging (MRI). The first excised lung image was obtained in 1994 by Albert et al ., indicating the relative youth of the HP gas MRI field. Thus, there are a multitude of parameters which need to be explored to optimize contrast mechanisms and pulse sequences for in vivo applications. To perform HP gas MRI, both the production of HP gas and development of appropriate MRI pulse sequences were necessary. The apparatus for gas polarization was transferred from Princeton University, then modified and optimized to provide larger quantities and higher polarizations. It was ultimately replaced by a prototype commercial apparatus. Existing MRI pulse sequences were changed to accommodate and exploit the unique situation of non-equilibrium polarized gas. Several physical parameters of the gas relating to structure and function in the lung were investigated. It was found that using a range of excitation powers, acquisition windows, and ventilatory cycle segments yielded dramatically different types of images in the guinea pig. Spatially localized lineshapes of HP 3He showed differentiated peaks (corresponding to frequency shifts) which represent gas in major airways (2 ppm) and alveoli (1-2 ppm). Quantitative maps of the diffusion coefficient (D) showed evidence of free diffusion in the trachea (average of 2.4 cm2/s for 3He and 0.68 cm2/s for 129Xe) and restricted diffusion combined with effects of gas mixtures in the distal pulmonary airspaces (average of 0.16 cm2/s for 3He and 0.021 cm2/s for 129Xe). Experimental measurements were verified with gas mixture and porous media theory for both 3He and 129Xe. The dephasing parameter, T*2 , was mapped showing sensitivity to changes in tidal volume and oxygen level. The T*2 values ranged from 9.2 to 15.9 ms in the intrapulmonary airspaces depending on the breathing paradigm. Experimental results were confirmed with porous media theory. Finally, the technique of D measurement was applied in a disease model. The histograms of D at end expiratory volume and 2 mL tidal volume held breath were shown to exhibit a significant shift in a healthy rat, but not in an elastase-induced (a model for emphysema) rat.

  15. Evaluation of Commercially Available Open Circuit Scuba Regulators

    DTIC Science & Technology

    1987-08-01

    ANNEX B LIST OF MANUFACTURERS 1. AGA/IISIERSPIRO U.S. Distributor Intersiro AB AGA/INTERSPIRO S-181 81 Lidingo Sweden Pistol Shop Road Rockfall ...RWV--*-- 40.0 RWV DACOR PACER XLE360 --G- 2.5 OW 600 80 1000 psig Supply Pressure -=70 -- 500 6050 7040 . GI "C - 300 , 𔄃° 4O- 30 200 0100 1030 0 0 0

  16. Astronaut Mary Ellen Weber during training session in WETF

    NASA Image and Video Library

    1994-05-01

    Attired in a training version of the Extravehicular Mobility Unit (EMU), Astronaut Mary Ellen Weber participates in a training session at JSC's Weightless Environment Training Facility (WETF). Training as a mission specialist for the STS-70 mission, Weber was about to rehearse a contingency space walk. One of several SCUBA-equipped divers waits to assist in the rehearsal in the water.

  17. Astronaut Tamara Jernigan deploys life raft during WETF training

    NASA Technical Reports Server (NTRS)

    1994-01-01

    Astronaut Tamara E. Jernigan, STS-67 payload commander, deploys a life raft during a session of emergency bailout training. The training took place in the 25-feet deep pool at JSC's Weightless Environment Training Facility (WETF). Jernigan was joined by her crew mates for the training session. Several SCUBA-equipped divers who assisted in the training can be seen in this photograph.

  18. Are the Keys loved to death? A study of diver specialization levels and preferences in the Florida Keys

    Treesearch

    Shona Paterson; David K. Loomis

    2010-01-01

    This paper presents research conducted for the Florida Reef Resilience Program on nonresident recreational SCUBA divers in three zones of the Florida Keys. When divers were segmented into specialization subgroups for analysis, divers in different subgroups tended to use different geographic locations. These results suggest differences in user preferences; yet when...

  19. The Educational Value of High Risk Activities in the Physical Education Program: A Social Philosophical Perspective.

    ERIC Educational Resources Information Center

    Sparks, Robert E. C.

    A growing number of schools and institutions in North America have begun offering training in high risk activities such as high element rope courses, rock climbing, white water kayaking and canoeing, and scuba diving in conjunction with their regular physical education activity programs. High risk activities are those activities which occur in or…

  20. Automated Airdrop Information Retrieval System-Human Fact ors Database (AAIRS-HFD) (Users Manual)

    DTIC Science & Technology

    1994-09-01

    creeps, or chokes) Pressure Change Disorders Loss of Sensorimotor Abilities Loss of Cognitive/Perceptual Abilities Treatment drug therapy ...physical therapy cognitive therapy biofeedback therapy 73 9. Psychological Factors Situational Awareness altitude awareness Visual/Spatial...on/off valve prebreather Floatation Devices life preserver Scuba Gear Ankle Braces Knee Braces/Pads 82 7. Cargo/Resupply Parachute Assembly

  1. User fees across ecosystem boundaries: Are SCUBA divers willing to pay for terrestrial biodiversity conservation?

    PubMed

    Roberts, Michaela; Hanley, Nick; Cresswell, Will

    2017-09-15

    While ecological links between ecosystems have been long recognised, management rarely crosses ecosystem boundaries. Coral reefs are susceptible to damage through terrestrial run-off, and failing to account for this within management threatens reef protection. In order to quantify the extent to that coral reef users are willing to support management actions to improve ecosystem quality, we conducted a choice experiment with SCUBA divers on the island of Bonaire, Caribbean Netherlands. Specifically, we estimated their willingness to pay to reduce terrestrial overgrazing as a means to improve reef health. Willingness to pay was estimated using the multinomial, random parameter and latent class logit models. Willingness to pay for improvements to reef quality was positive for the majority of respondents. Estimates from the latent class model determined willingness to pay for reef improvements of between $31.17 - $413.18/year, dependent on class membership. This represents a significant source of funding for terrestrial conservation, and illustrates the potential for user fees to be applied across ecosystem boundaries. We argue that such across-ecosystem-boundary funding mechanisms are an important avenue for future investigation in many connected systems. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Wide-field SCUBA-2 observations of NGC 2264: submillimetre clumps and filaments

    NASA Astrophysics Data System (ADS)

    Buckle, J. V.; Richer, J. S.

    2015-10-01

    We present wide-field observations of the NGC 2264 molecular cloud in the dust continuum at 850 and 450 μm using SCUBA-2 on the James Clerk Maxwell Telescope. Using 12CO 3 → 2 molecular line data, we determine that emission from CO contaminates the 850 μm emission at levels ˜30 per cent in localized regions associated with high-velocity molecular outflows. Much higher contamination levels of 60 per cent are seen in shocked regions near the massive star S Mon. If not removed, the levels of CO contamination would contribute an extra 13 per cent to the dust mass in NGC 2264. We use the FELLWALKER routine to decompose the dust into clumpy structures, and a Hessian-based routine to decompose the dust into filamentary structures. The filaments can be described as a hub-filament structure, with lower column density filaments radiating from the NGC 2264 C protocluster hub. Above mean filament column densities of 2.4 × 1022 cm-2, star formation proceeds with the formation of two or more protostars. Below these column densities, filaments are starless, or contain only a single protostar.

  3. The AGN fraction of submm-selected galaxies and contributions to the submm/mm-wave extragalactic background light

    NASA Astrophysics Data System (ADS)

    Serjeant, S.; Negrello, M.; Pearson, C.; Mortier, A.; Austermann, J.; Aretxaga, I.; Clements, D.; Chapman, S.; Dye, S.; Dunlop, J.; Dunne, L.; Farrah, D.; Hughes, D.; Lee, H.-M.; Matsuhara, H.; Ibar, E.; Im, M.; Jeong, W.-S.; Kim, S.; Oyabu, S.; Takagi, T.; Wada, T.; Wilson, G.; Vaccari, M.; Yun, M.

    2010-05-01

    We present a comparison of the SCUBA half degree extragalactic survey (SHADES) at 450 μm, 850 μm and 1100 μm with deep guaranteed time 15 μm AKARI FU-HYU survey data and Spitzer guaranteed time data at 3.6-24 μm in the Lockman hole east. The AKARI data was analysed using bespoke software based in part on the drizzling and minimum-variance matched filtering developed for SHADES, and was cross-calibrated against ISO fluxes. Our stacking analyses find AKARI 15 μm galaxies with ⪆200 μJy contribute >10% of the 450 μm background, but only <4% of the 1100 μm background, suggesting that different populations contribute at mm-wavelengths. We confirm our earlier result that the ultra-deep 450 μm SCUBA-2 cosmology survey will be dominated by populations already detected by AKARI and Spitzer mid-infrared surveys. The superb mid-infrared wavelength coverage afforded by combining Spitzer and AKARI photometry is an excellent diagnostic of AGN contributions, and we find that (23-52)% of submm-selected galaxies have AGN bolometric fractions fAGN > 0.3.

  4. First Tests of Prototype SCUBA-2 Superconducting Bolometer Array

    NASA Astrophysics Data System (ADS)

    Woodcraft, Adam L.; Ade, Peter A. R.; Bintley, Dan; Hunt, Cynthia L.; Sudiwala, Rashmi V.; Hilton, Gene C.; Irwin, Kent D.; Reintsema, Carl D.; Audley, Michael D.; Holland, Wayne S.; MacIntosh, Mike

    2006-09-01

    We present results of the first tests on a 1280 pixel superconducting bolometer array, a prototype for SCUBA-2, a sub-mm camera being built for the James Clerk Maxwell Telescope in Hawaii. The bolometers are TES (transition edge sensor) detectors; these take advantage of the large variation of resistance with temperature through the superconducting transition. To keep the number of wires reasonable, a multiplexed read-out is used. Each pixel is read out through an individual DC SQUID; room temperature electronics switch between rows in the array by biasing the appropriate SQUIDs in turn. Arrays of 100 SQUIDs in series for each column then amplify the output. Unlike previous TES arrays, the multiplexing elements are located beneath each pixel, making large arrays possible, but construction more challenging. The detectors are constructed from Mo/Cu bi-layers; this technique enables the transition temperature to be tuned using the proximity effect by choosing the thickness of the normal and superconducting materials. To achieve the required performance, the detectors are operated at a temperature of approximately 120 mK. We describe the results of a basic characterisation of the array, demonstrating that it is fully operational, and give the results of signal to noise measurements.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thun, M.; Kimbrough, R.D.

    Fatal chemical pneumonia occurred in a worker following exposure to an unidentified gas in a salvaged cylinder. Inspection of the tank revealed a scrawled chemical formula for 1,1,2,3,3-pentafluoro-3-chloropropene, a suspected pulmonary irritant. The report underscores the potential hazards which salvaged cylinders pose to individuals who use or refill them. The population at risk includes scuba divers, emergency rescue personnel, and workers in the compressed gas industry.

  6. Astronaut John Grunsfeld during EVA training in the WETF

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Astronaut John M. Grunsfeld, STS-67 mission specialist, gives a salute as he is about to be submerged in a 25-feet deep pool in JSC's Weightless Environment Training Facility (WETF). Wearing a special training version of the Extravehicular Mobility Unit (EMU) space suit and assisted by several JSC SCUBA-equipped divers, Grunsfeld was later using the pool to rehearse contingency space walk chores.

  7. STS-46 Payload Specialist Malerba in JSC's WETF pool during egress training

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, Italian Payload Specialist Franco Malerba, wearing launch and entry suit (LES) and clamshell helmet, laughes as he floats in JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. Malerba's flotation vest (life jacket) and two SCUBA-equipped divers keep him afloat after he was dropped into the pool during a launch emergency egress simulation.

  8. The SCUBA-2 Cosmology Legacy Survey: 850 μm maps, catalogues and number counts

    NASA Astrophysics Data System (ADS)

    Geach, J. E.; Dunlop, J. S.; Halpern, M.; Smail, Ian; van der Werf, P.; Alexander, D. M.; Almaini, O.; Aretxaga, I.; Arumugam, V.; Asboth, V.; Banerji, M.; Beanlands, J.; Best, P. N.; Blain, A. W.; Birkinshaw, M.; Chapin, E. L.; Chapman, S. C.; Chen, C.-C.; Chrysostomou, A.; Clarke, C.; Clements, D. L.; Conselice, C.; Coppin, K. E. K.; Cowley, W. I.; Danielson, A. L. R.; Eales, S.; Edge, A. C.; Farrah, D.; Gibb, A.; Harrison, C. M.; Hine, N. K.; Hughes, D.; Ivison, R. J.; Jarvis, M.; Jenness, T.; Jones, S. F.; Karim, A.; Koprowski, M.; Knudsen, K. K.; Lacey, C. G.; Mackenzie, T.; Marsden, G.; McAlpine, K.; McMahon, R.; Meijerink, R.; Michałowski, M. J.; Oliver, S. J.; Page, M. J.; Peacock, J. A.; Rigopoulou, D.; Robson, E. I.; Roseboom, I.; Rotermund, K.; Scott, Douglas; Serjeant, S.; Simpson, C.; Simpson, J. M.; Smith, D. J. B.; Spaans, M.; Stanley, F.; Stevens, J. A.; Swinbank, A. M.; Targett, T.; Thomson, A. P.; Valiante, E.; Wake, D. A.; Webb, T. M. A.; Willott, C.; Zavala, J. A.; Zemcov, M.

    2017-02-01

    We present a catalogue of ˜3000 submillimetre sources detected (≥3.5σ) at 850 μm over ˜5 deg2 surveyed as part of the James Clerk Maxwell Telescope (JCMT) SCUBA-2 Cosmology Legacy Survey (S2CLS). This is the largest survey of its kind at 850 μm, increasing the sample size of 850 μm selected submillimetre galaxies by an order of magnitude. The wide 850 μm survey component of S2CLS covers the extragalactic fields: UKIDSS-UDS, COSMOS, Akari-NEP, Extended Groth Strip, Lockman Hole North, SSA22 and GOODS-North. The average 1σ depth of S2CLS is 1.2 mJy beam-1, approaching the SCUBA-2 850 μm confusion limit, which we determine to be σc ≈ 0.8 mJy beam-1. We measure the 850 μm number counts, reducing the Poisson errors on the differential counts to approximately 4 per cent at S850 ≈ 3 mJy. With several independent fields, we investigate field-to-field variance, finding that the number counts on 0.5°-1° scales are generally within 50 per cent of the S2CLS mean for S850 > 3 mJy, with scatter consistent with the Poisson and estimated cosmic variance uncertainties, although there is a marginal (2σ) density enhancement in GOODS-North. The observed counts are in reasonable agreement with recent phenomenological and semi-analytic models, although determining the shape of the faint-end slope (S850 < 3 mJy) remains a key test. The large solid angle of S2CLS allows us to measure the bright-end counts: at S850 > 10 mJy there are approximately 10 sources per square degree, and we detect the distinctive up-turn in the number counts indicative of the detection of local sources of 850 μm emission, and strongly lensed high-redshift galaxies. All calibrated maps and the catalogue are made publicly available.

  9. The SCUBA HAlf Degree Extragalactic Survey (SHADES) - V. Submillimetre properties of near-infrared-selected galaxies in the Subaru/XMM -Newton deep field

    NASA Astrophysics Data System (ADS)

    Takagi, T.; Mortier, A. M. J.; Shimasaku, K.; Coppin, K.; Pope, A.; Ivison, R. J.; Hanami, H.; Serjeant, S.; Clements, D. L.; Priddey, R. S.; Dunlop, J. S.; Takata, T.; Aretxaga, I.; Chapman, S. C.; Eales, S. A.; Farrah, D.; Granato, G. L.; Halpern, M.; Hughes, D. H.; van Kampen, E.; Scott, D.; Sekiguchi, K.; Smail, I.; Vaccari, M.

    2007-11-01

    We have studied the submillimetre (submm) properties of the following classes of near-infrared-selected (NIR-selected) massive galaxies at high redshifts: BzK-selected star-forming galaxies (BzKs); distant red galaxies (DRGs); and extremely red objects (EROs). We used the SCUBA HAlf Degree Extragalactic Survey (SHADES), the largest uniform submm survey to date. Partial overlap of SIRIUS/NIR images and SHADES in Subaru/XMM-Newton deep field has allowed us to identify four submm-bright NIR-selected galaxies, which are detected in the mid-IR, 24μ m, and the radio, 1.4GHz. We find that all of our submm-bright NIR-selected galaxies satisfy the BzK selection criteria, i.e. BzK ≡ (z - K)AB - (B - z)AB >= -0.2, except for one galaxy whose B - z and z - K colours are however close to the BzK colour boundary. Two of the submm-bright NIR-selected galaxies satisfy all of the selection criteria we considered, i.e. they belong to the BzK-DRG-ERO overlapping population, or `extremely red' BzKs. Although these extremely red BzKs are rare (0.25 arcmin-2), up to 20 per cent of this population could be submm galaxies. This fraction is significantly higher than that found for other galaxy populations studied here. Via a stacking analysis, we have detected the 850-μ m flux of submm-faint BzKs and EROs in our SCUBA maps. While the contribution of z ~ 2 BzKs to the submm background is about 10-15 per cent and similar to that from EROs typically at z ~ 1, BzKs have a higher fraction (~30 per cent) of submm flux in resolved sources compared with EROs and submm sources as a whole. From the spectral energy distribution (SED) fitting analysis for both submm-bright and submm-faint BzKs, we found no clear signature that submm-bright BzKs are experiencing a specifically luminous evolutionary phase, compared with submm-faint BzKs. An alternative explanation might be that submm-bright BzKs are more massive than submm-faint ones.

  10. High-resolution SMA imaging of bright submillimetre sources from the SCUBA-2 Cosmology Legacy Survey

    NASA Astrophysics Data System (ADS)

    Hill, Ryley; Chapman, Scott C.; Scott, Douglas; Petitpas, Glen; Smail, Ian; Chapin, Edward L.; Gurwell, Mark A.; Perry, Ryan; Blain, Andrew W.; Bremer, Malcolm N.; Chen, Chian-Chou; Dunlop, James S.; Farrah, Duncan; Fazio, Giovanni G.; Geach, James E.; Howson, Paul; Ivison, R. J.; Lacaille, Kevin; Michałowski, Michał J.; Simpson, James M.; Swinbank, A. M.; van der Werf, Paul P.; Wilner, David J.

    2018-06-01

    We have used the Submillimeter Array (SMA) at 860 μm to observe the brightest sources in the Submillimeter Common User Bolometer Array-2 (SCUBA-2) Cosmology Legacy Survey (S2CLS). The goal of this survey is to exploit the large field of the S2CLS along with the resolution and sensitivity of the SMA to construct a large sample of these rare sources and to study their statistical properties. We have targeted 70 of the brightest single-dish SCUBA-2 850 μm sources down to S850 ≈ 8 mJy, achieving an average synthesized beam of 2.4 arcsec and an average rms of σ860 = 1.5 mJy beam-1 in our primary beam-corrected maps. We searched our SMA maps for 4σ peaks, corresponding to S860 ≳ 6 mJy sources, and detected 62, galaxies, including three pairs. We include in our study 35 archival observations, bringing our sample size to 105 bright single-dish submillimetre sources with interferometric follow-up. We compute the cumulative and differential number counts, finding them to overlap with previous single-dish survey number counts within the uncertainties, although our cumulative number count is systematically lower than the parent S2CLS cumulative number count by 14 ± 6 per cent between 11 and 15 mJy. We estimate the probability that a ≳10 mJy single-dish submillimetre source resolves into two or more galaxies with similar flux densities to be less than 15 per cent. Assuming the remaining 85 per cent of the targets are ultraluminous starburst galaxies between z = 2 and 3, we find a likely volume density of ≳400 M⊙ yr-1 sources to be {˜ } 3^{+0.7}_{-0.6} {× } 10^{-7} Mpc-3. We show that the descendants of these galaxies could be ≳4 × 1011 M⊙ local quiescent galaxies, and that about 10 per cent of their total stellar mass would have formed during these short bursts of star formation.

  11. Systemic exposure to PAHs and benzene in firefighters suppressing controlled structure fires.

    PubMed

    Fent, Kenneth W; Eisenberg, Judith; Snawder, John; Sammons, Deborah; Pleil, Joachim D; Stiegel, Matthew A; Mueller, Charles; Horn, Gavin P; Dalton, James

    2014-08-01

    Turnout gear provides protection against dermal exposure to contaminants during firefighting; however, the level of protection is unknown. We explored the dermal contribution to the systemic dose of polycyclic aromatic hydrocarbons (PAHs) and other aromatic hydrocarbons in firefighters during suppression and overhaul of controlled structure burns. The study was organized into two rounds, three controlled burns per round, and five firefighters per burn. The firefighters wore new or laundered turnout gear tested before each burn to ensure lack of PAH contamination. To ensure that any increase in systemic PAH levels after the burn was the result of dermal rather than inhalation exposure, the firefighters did not remove their self-contained breathing apparatus until overhaul was completed and they were >30 m upwind from the burn structure. Specimens were collected before and at intervals after the burn for biomarker analysis. Urine was analyzed for phenanthrene equivalents using enzyme-linked immunosorbent assay and a benzene metabolite (s-phenylmercapturic acid) using liquid chromatography/tandem mass spectrometry; both were adjusted by creatinine. Exhaled breath collected on thermal desorption tubes was analyzed for PAHs and other aromatic hydrocarbons using gas chromatography/mass spectrometry. We collected personal air samples during the burn and skin wipe samples (corn oil medium) on several body sites before and after the burn. The air and wipe samples were analyzed for PAHs using a liquid chromatography with photodiode array detection. We explored possible changes in external exposures or biomarkers over time and the relationships between these variables using non-parametric sign tests and Spearman tests, respectively. We found significantly elevated (P < 0.05) post-exposure breath concentrations of benzene compared with pre-exposure concentrations for both rounds. We also found significantly elevated post-exposure levels of PAHs on the neck compared with pre-exposure levels for round 1. We found statistically significant positive correlations between external exposures (i.e. personal air concentrations of PAHs) and biomarkers (i.e. change in urinary PAH metabolite levels in round 1 and change in breath concentrations of benzene in round 2). The results suggest that firefighters wearing full protective ensembles absorbed combustion products into their bodies. The PAHs most likely entered firefighters' bodies through their skin, with the neck being the primary site of exposure and absorption due to the lower level of dermal protection afforded by hoods. Aromatic hydrocarbons could have been absorbed dermally during firefighting or inhaled during the doffing of gear that was off-gassing contaminants. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  12. Systemic Exposure to PAHs and Benzene in Firefighters Suppressing Controlled Structure Fires

    PubMed Central

    Fent, Kenneth W.; Eisenberg, Judith; Snawder, John; Sammons, Deborah; Pleil, Joachim D.; Stiegel, Matthew A.; Mueller, Charles; Horn, Gavin P.; Dalton, James

    2014-01-01

    Turnout gear provides protection against dermal exposure to contaminants during firefighting; however, the level of protection is unknown. We explored the dermal contribution to the systemic dose of polycyclic aromatic hydrocarbons (PAHs) and other aromatic hydrocarbons in firefighters during suppression and overhaul of controlled structure burns. The study was organized into two rounds, three controlled burns per round, and five firefighters per burn. The firefighters wore new or laundered turnout gear tested before each burn to ensure lack of PAH contamination. To ensure that any increase in systemic PAH levels after the burn was the result of dermal rather than inhalation exposure, the firefighters did not remove their self-contained breathing apparatus until overhaul was completed and they were >30 m upwind from the burn structure. Specimens were collected before and at intervals after the burn for biomarker analysis. Urine was analyzed for phenanthrene equivalents using enzyme-linked immunosorbent assay and a benzene metabolite (s-phenylmercapturic acid) using liquid chromatography/tandem mass spectrometry; both were adjusted by creatinine. Exhaled breath collected on thermal desorption tubes was analyzed for PAHs and other aromatic hydrocarbons using gas chromatography/mass spectrometry. We collected personal air samples during the burn and skin wipe samples (corn oil medium) on several body sites before and after the burn. The air and wipe samples were analyzed for PAHs using a liquid chromatography with photodiode array detection. We explored possible changes in external exposures or biomarkers over time and the relationships between these variables using non-parametric sign tests and Spearman tests, respectively. We found significantly elevated (P < 0.05) post-exposure breath concentrations of benzene compared with pre-exposure concentrations for both rounds. We also found significantly elevated post-exposure levels of PAHs on the neck compared with pre-exposure levels for round 1. We found statistically significant positive correlations between external exposures (i.e. personal air concentrations of PAHs) and biomarkers (i.e. change in urinary PAH metabolite levels in round 1 and change in breath concentrations of benzene in round 2). The results suggest that firefighters wearing full protective ensembles absorbed combustion products into their bodies. The PAHs most likely entered firefighters’ bodies through their skin, with the neck being the primary site of exposure and absorption due to the lower level of dermal protection afforded by hoods. Aromatic hydrocarbons could have been absorbed dermally during firefighting or inhaled during the doffing of gear that was off-gassing contaminants. PMID:24906357

  13. Evolution of Air Breathing: Oxygen Homeostasis and the Transitions from Water to Land and Sky

    PubMed Central

    Hsia, Connie C. W.; Schmitz, Anke; Lambertz, Markus; Perry, Steven F.; Maina, John N.

    2014-01-01

    Life originated in anoxia, but many organisms came to depend upon oxygen for survival, independently evolving diverse respiratory systems for acquiring oxygen from the environment. Ambient oxygen tension (PO2) fluctuated through the ages in correlation with biodiversity and body size, enabling organisms to migrate from water to land and air and sometimes in the opposite direction. Habitat expansion compels the use of different gas exchangers, for example, skin, gills, tracheae, lungs, and their intermediate stages, that may coexist within the same species; coexistence may be temporally disjunct (e.g., larval gills vs. adult lungs) or simultaneous (e.g., skin, gills, and lungs in some salamanders). Disparate systems exhibit similar directions of adaptation: toward larger diffusion interfaces, thinner barriers, finer dynamic regulation, and reduced cost of breathing. Efficient respiratory gas exchange, coupled to downstream convective and diffusive resistances, comprise the “oxygen cascade”—step-down of PO2 that balances supply against toxicity. Here, we review the origin of oxygen homeostasis, a primal selection factor for all respiratory systems, which in turn function as gatekeepers of the cascade. Within an organism's lifespan, the respiratory apparatus adapts in various ways to upregulate oxygen uptake in hypoxia and restrict uptake in hyperoxia. In an evolutionary context, certain species also become adapted to environmental conditions or habitual organismic demands. We, therefore, survey the comparative anatomy and physiology of respiratory systems from invertebrates to vertebrates, water to air breathers, and terrestrial to aerial inhabitants. Through the evolutionary directions and variety of gas exchangers, their shared features and individual compromises may be appreciated. PMID:23720333

  14. Evolution of air breathing: oxygen homeostasis and the transitions from water to land and sky.

    PubMed

    Hsia, Connie C W; Schmitz, Anke; Lambertz, Markus; Perry, Steven F; Maina, John N

    2013-04-01

    Life originated in anoxia, but many organisms came to depend upon oxygen for survival, independently evolving diverse respiratory systems for acquiring oxygen from the environment. Ambient oxygen tension (PO2) fluctuated through the ages in correlation with biodiversity and body size, enabling organisms to migrate from water to land and air and sometimes in the opposite direction. Habitat expansion compels the use of different gas exchangers, for example, skin, gills, tracheae, lungs, and their intermediate stages, that may coexist within the same species; coexistence may be temporally disjunct (e.g., larval gills vs. adult lungs) or simultaneous (e.g., skin, gills, and lungs in some salamanders). Disparate systems exhibit similar directions of adaptation: toward larger diffusion interfaces, thinner barriers, finer dynamic regulation, and reduced cost of breathing. Efficient respiratory gas exchange, coupled to downstream convective and diffusive resistances, comprise the "oxygen cascade"-step-down of PO2 that balances supply against toxicity. Here, we review the origin of oxygen homeostasis, a primal selection factor for all respiratory systems, which in turn function as gatekeepers of the cascade. Within an organism's lifespan, the respiratory apparatus adapts in various ways to upregulate oxygen uptake in hypoxia and restrict uptake in hyperoxia. In an evolutionary context, certain species also become adapted to environmental conditions or habitual organismic demands. We, therefore, survey the comparative anatomy and physiology of respiratory systems from invertebrates to vertebrates, water to air breathers, and terrestrial to aerial inhabitants. Through the evolutionary directions and variety of gas exchangers, their shared features and individual compromises may be appreciated.

  15. Voluntary control of breathing does not alter vagal modulation of heart rate

    NASA Technical Reports Server (NTRS)

    Patwardhan, A. R.; Evans, J. M.; Bruce, E. N.; Eckberg, D. L.; Knapp, C. F.

    1995-01-01

    Variations in respiratory pattern influence the heart rate spectrum. It has been suggested, hence, that metronomic respiration should be used to correctly assess vagal modulation of heart rate by using spectral analysis. On the other hand, breathing to a metronome has been reported to increase heart rate spectral power in the high- or respiratory frequency region; this finding has led to the suggestion that metronomic respiration enhances vagal tone or alters vagal modulation of heart rate. To investigate whether metronomic breathing complicates the interpretation of heart rate spectra by altering vagal modulation, we recorded the electrocardiogram and respiration from eight volunteers during three breathing trials of 10 min each: 1) spontaneous breathing (mean rate of 14.4 breaths/min); 2) breathing to a metronome at the rate of 15, 18, and 21 breaths/min for 2, 6, and 2 min, respectively; and 3) breathing to a metronome at the rate of 18 breaths/min for 10 min. Data were also collected from eight volunteers who breathed spontaneously for 20 min and breathed metronomically at each subject's mean spontaneous breathing frequency for 20 min. Results from the three 10-min breathing trials showed that heart rate power in the respiratory frequency region was smaller during metronomic breathing than during spontaneous breathing. This decrease could be explained fully by the higher breathing frequencies used during trials 2 and 3 of metronomic breathing. When the subjects breathed metronomically at each subject's mean breathing frequency, the heart rate powers during metronomic breathing were similar to those during spontaneous breathing. Our results suggest that vagal modulation of heart rate is not altered and vagal tone is not enhanced during metronomic breathing.

  16. Complement Proteins and Decompression Sickness Susceptibility.

    DTIC Science & Technology

    1992-07-01

    scuba diving, other hyperbaric exposures, hypobaric exposures, or flying would be permitted for one week prior to the blood draws. Table 1. Subject...subjected to a series of hyperbaric profiles that were severe enough to produce Doppler- detectable VGE. The individuals identified as more sensitive to...by Ward et al. (18,22). Greater rates tended to cause excessive foam above the sample. The diameter of the bubbles was determined by comparison with

  17. STS-45 backup Payload Specialist Chappell during water egress training at JSC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-45 Atlantis, Orbiter Vehicle (OV) 104, backup Payload Specialist Charles R. Chappell, wearing launch and entry suit (LES), is suspended via his parachute harness above JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. Chappell will be dropped into the pool during the exercise which simulates a parachute landing into a body of water. SCUBA-equipped divers swimming in the pool will assist during the training.

  18. Astronauts and cosmonauts during emergency bailout training session

    NASA Image and Video Library

    1994-10-13

    S94-47226 (13 Oct 1994) --- Using small life rafts, several cosmonauts and astronauts participating in joint Russia - United States space missions take part in an emergency bailout training session in the Johnson Space Center's (JSC) Weightless Environment Training Facility's (WET-F) 25-feet-deep pool. In the foreground is cosmonaut Alexsandr F. Poleshchuk, a member of the Mir reserve crew. A number of SCUBA-equipped divers assist the trainees.

  19. Suez Canal Clearance Operation, Task Force 65

    DTIC Science & Technology

    1975-05-01

    supporting minesweepers, GARDENIA, GIROFLEE, AJONC, and LILAS, and two minehunters CERES and CALLIOPE. TG SIX FIVE POINT ZERO . This Task Group designation...circle search line, buoy line, tether, zero visibility, and no communication with the surface, created a hazardous situation for open circuit scuba...from essentially zero to several hut7Ared thousand in Port Said and Suez City, and to a lesser degree in Ismailia. This occurred without a concomitant

  20. STS-46 Pilot Allen and Payload Specialist Malerba in life rafts at JSC's WEFT

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-46 Atlantis, Orbiter Vehicle (OV) 104, Pilot Andrew M. Allen (foreground) and Italian Payload Specialist Franco Malerba, wearing launch and entry suits (LESs) and launch and entry helmets (LEHs), float in one-person life rafts during a launch emergency egress (bailout) simulation in JSC's Weightless Environment Training Facility (WETF) Bldg 29 pool. A SCUBA-equipped diver assists in the training activity.

  1. The GISMO two-millimeter deep field in GOODS-N

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Staguhn, Johannes G.; Kovács, Attila; Arendt, Richard G.

    2014-07-20

    We present deep continuum observations using the GISMO camera at a wavelength of 2 mm centered on the Hubble Deep Field in the GOODS-N field. These are the first deep field observations ever obtained at this wavelength. The 1σ sensitivity in the innermost ∼4' of the 7' diameter map is ∼135 μJy beam{sup –1}, a factor of three higher in flux/beam sensitivity than the deepest available SCUBA 850 μm observations, and almost a factor of four higher in flux/beam sensitivity than the combined MAMBO/AzTEC 1.2 mm observations of this region. Our source extraction algorithm identifies 12 sources directly, and anothermore » 3 through correlation with known sources at 1.2 mm and 850 μm. Five of the directly detected GISMO sources have counterparts in the MAMBO/AzTEC catalog, and four of those also have SCUBA counterparts. HDF850.1, one of the first blank-field detected submillimeter galaxies, is now detected at 2 mm. The median redshift of all sources with counterparts of known redshifts is z-tilde =2.91±0.94. Statistically, the detections are most likely real for five of the seven 2 mm sources without shorter wavelength counterparts, while the probability for none of them being real is negligible.« less

  2. The subsurface of Pluto from submillimetre observations

    NASA Astrophysics Data System (ADS)

    Greaves, J. S.; Whitelaw, A. C. M.; Bendo, G. J.

    2015-04-01

    Surface areas on Pluto change in brightness and colour, at optical to infrared wavelengths, over time-scales as short as years. The subsurface contains a reservoir of frozen volatiles, but little is known about it because Pluto is out of reach for cm-radar. Here we present a 0.85 mm wavelength light curve of the Pluto system, from archival data taken in 1997 August with the SCUBA (Submillimetre Common-User Bolometer Array) camera on the James Clerk Maxwell Telescope (JCMT). This wavelength probes for the first time to just below the skin depth of thermal changes over Pluto's day. The light curve differs significantly from counterparts in the mid- to far-infrared, in a longitude range that is optically dark on Pluto's surface. An estimate from Herschel of the 0.5 mm flux in 2012 is comparable to the mean 0.45 mm flux from SCUBA in 1997, suggesting that layers centimetres below the surface have not undergone any gross temperature change. The longitudes that are relatively submillimetre-faint could have a different emissivity, perhaps with a subsurface layer richer in nitrogen or methane ices than at the surface. The Radio Science Experiment (REX) instrument on New Horizons may be able to constrain physical properties deeper down, as it looks back on Pluto's nightside after the 2015 July flyby.

  3. The Relationship between Diver Experience Levels and Perceptions of Attractiveness of Artificial Reefs - Examination of a Potential Management Tool

    PubMed Central

    Kirkbride-Smith, Anne E.; Wheeler, Philip M.; Johnson, Magnus L.

    2013-01-01

    Artificial reefs are increasingly used worldwide as a method for managing recreational diving since they have the potential to satisfy both conservation goals and economic interests. In order to help maximize their utility, further information is needed to drive the design of stimulating resources for scuba divers. We used a questionnaire survey to explore divers’ perceptions of artificial reefs in Barbados. In addition, we examined reef resource substitution behaviour among scuba divers. Divers expressed a clear preference for large shipwrecks or sunken vessels that provided a themed diving experience. Motives for diving on artificial reefs were varied, but were dominated by the chance of viewing concentrated marine life, increased photographic opportunities, and the guarantee of a ‘good dive’. Satisfaction with artificial reef diving was high amongst novices and declined with increasing experience. Experienced divers had an overwhelming preference for natural reefs. As a management strategy, our results emphasize the capacity of well designed artificial reefs to contribute towards the management of coral reef diving sites and highlight a number of important areas for future research. Suggested work should validate the present findings in different marine tourism settings and ascertain support of artificial reefs in relationship to level of diver specialization. PMID:23894372

  4. Mapping nuclear craters on Enewetak Atoll, Marshall Islands

    USGS Publications Warehouse

    Hampson, John C., Jr.

    1986-01-01

    In 1984, the U.S. Geological Survey conducted a detailed geologic analysis of two nuclear test craters at Enewetak Atoll, Marshall Islands, on behalf of the Defense Nuclear Agency. A multidisciplinary task force mapped the morphology, surface character, and subsurface structure of two craters, OAK and KOA. The field mapping techniques include echo sounding, sidescan sonar imaging, single-channel and multichannel seismic reflection profiling, a seismic refraction survey, and scuba and submersible operations. All operations had to be navigated precisely and correlatable with subsequent drilling and sampling operations. Mapping with a high degree of precision at scales as large as 1:1500 required corrections that often are not considered in marine mapping. Corrections were applied to the bathymetric data for location of the echo- sounding transducer relative to the navigation transponder on the ship and for transducer depth, speed of sound, and tidal variations. Sidescan sonar, single-channel seismic reflection, and scuba and submersible data were correlated in depth and map position with the bathymetric data to provide a precise, internally consistent data set. The multichannel and refraction surveys were conducted independently but compared well with bathymetry. Examples drawn from processing the bathymetric, sidescan sonar, and single- channel reflection data help illustrate problems and procedures in precision mapping.

  5. Underwater Acoustic Source Localisation Among Blind and Sighted Scuba Divers: Comparative study.

    PubMed

    Cambi, Jacopo; Livi, Ludovica; Livi, Walter

    2017-05-01

    Many blind individuals demonstrate enhanced auditory spatial discrimination or localisation of sound sources in comparison to sighted subjects. However, this hypothesis has not yet been confirmed with regards to underwater spatial localisation. This study therefore aimed to investigate underwater acoustic source localisation among blind and sighted scuba divers. This study took place between February and June 2015 in Elba, Italy, and involved two experimental groups of divers with either acquired (n = 20) or congenital (n = 10) blindness and a control group of 30 sighted divers. Each subject took part in five attempts at an under-water acoustic source localisation task, in which the divers were requested to swim to the source of a sound originating from one of 24 potential locations. The control group had their sight obscured during the task. The congenitally blind divers demonstrated significantly better underwater sound localisation compared to the control group or those with acquired blindness ( P = 0.0007). In addition, there was a significant correlation between years of blindness and underwater sound localisation ( P <0.0001). Congenital blindness was found to positively affect the ability of a diver to recognise the source of a sound in an underwater environment. As the correct localisation of sounds underwater may help individuals to avoid imminent danger, divers should perform sound localisation tests during training sessions.

  6. Peripheral cold acclimatization in Antarctic scuba divers.

    PubMed

    Bridgman, S A

    1991-08-01

    Peripheral acclimatization to cold in scuba divers stationed at the British Antarctic Survey's Signy Station was investigated during a year in Antarctica. Five divers and five non-diver controls underwent monthly laboratory tests of index finger immersion in cold water for 30 min. Index finger pulp temperature and time of onset of cold-induced vasodilatation (CIVD) were measured. Pain was recorded with verbal and numerical psychophysical subjective pain ratings. Average finger temperatures and median finger pain from 6-30 min of immersion, maximum finger temperatures during the first CIVD cycle, and finger temperatures at the onset of CIVD were calculated. Comparison of the variables recorded from divers and non-divers were performed with analysis of variance. No significant differences were found among the variables recorded from divers and non-divers. From a review of the literature, divers have responses typical of non-cold-adapted Caucasians. There is, therefore, no evidence that Signy divers peripherally acclimatized to cold. We suggest that these findings occur because either the whole body cooling which divers undergo inhibits peripheral acclimatization or because of insufficiently frequent or severe cold exposure while diving. Further basic studies on the duration, frequency and severity of cold exposure necessary to induce peripheral cold acclimatization are required before this question can be satisfactorily answered.

  7. Fatal injuries in the United States involving respirators, 1984-1995.

    PubMed

    Suruda, Anthony; Milliken, William; Stephenson, Dale; Sesek, Richard

    2003-04-01

    There is little published information concerning the epidemiology of fatal injuries involving respiratory protection. We compiled a case series from U.S. Occupational Safety and Health Administration investigation reports from 1984 through 1995. For the 12-year period there were 41 incidents resulting in 45 deaths due to asphyxiation or chemical poisoning while wearing a respirator. There were 23 deaths related to airline respirators, 17 deaths involving use of negative pressure (air purifying) respirators, and 5 deaths involving self-contained breathing apparatus. Among the 23 deaths involving airline respirators, 15 were associated with compatible connection couplings for breathable air and inert gases. Three workers with beards died who wore tight-fitting respirators in an atmosphere that was immediately dangerous to life and health. Most of the fatalities involved regulatory and procedural violations, and would have been prevented by proper training and compliance with existing regulations. The information concerning the victims was limited but it did not appear that medical screening would have prevented any of the deaths.

  8. Joubert syndrome: congenital cerebellar ataxia with the “molar tooth”

    PubMed Central

    Romani, Marta; Micalizzi, Alessia; Valente, Enza Maria

    2013-01-01

    Joubert syndrome (JS) is a congenital cerebellar ataxia with autosomal recessive or X-linked inheritance, which diagnostic hallmark is a unique cerebellar and brainstem malformation recognizable on brain imaging, the “molar tooth sign”. Neurological signs are present from neonatal age and include hypotonia evolving into ataxia, global developmental delay, ocular motor apraxia and breathing dysregulation. These are variably associated with multiorgan involvement, mainly of the retina, kidneys, skeleton and liver. To date, 21 causative genes have been identified, all encoding for proteins of the primary cilium or its apparatus. This is a subcellular organelle that plays key roles in development and in many cellular functions, making JS part of the expanding family of ciliopathies. There is marked clinical and genetic overlap among distinct ciliopathies, which may co-occur even within families. Such variability is likely explained by an oligogenic model of inheritance, in which mutations, rare variants and polymorphisms at distinct loci interplay to modulate the expressivity of the ciliary phenotype. PMID:23870701

  9. Impact of SCBA size and firefighting work cycle on firefighter functional balance.

    PubMed

    Kesler, Richard M; Deetjen, Grace S; Bradley, Faith F; Angelini, Michael J; Petrucci, Matthew N; Rosengren, Karl S; Horn, Gavin P; Hsiao-Wecksler, Elizabeth T

    2018-05-01

    Slips, trips and falls are leading causes of fireground injuries. A functional balance test (FBT) was used to investigate the effects of self-contained breathing apparatus (SCBA) size and design, plus firefighting work cycle. During the FBT, subjects walked along a narrow platform and turned in defined spaces, with and without an overhead obstacle. Thirty firefighters wore three varying-sized standard SCBAs and a low-profile prototype SCBA during three simulated firefighting work/rest cycles. Firefighters were tested pre- and post-firefighting activity (one bout, two bouts with a 5-min break, or back-to-back bouts with no break). Subjects committed more errors and required longer completion times with larger SCBAs. Use of the prototype SCBA lead to lower times and fewer errors. Performing a second bout of firefighting increased completion time. Firefighters need to consider how SCBA and amount of physical activity on the fireground may influence balance in order to reduce the risk of injury. Copyright © 2018 Elsevier Ltd. All rights reserved.

  10. Lox breathing system with gas permeable-liquid impermeable heat exchange and delivery hose

    DOEpatents

    Hall, Mark N.

    1996-01-01

    Life support apparatus composed of: a garment (2): for completely enclosing a wearer and constructed for preventing passage of gas from the environment surrounding the garment (2); a portable receptacle (6) holding a quantity of an oxygen-containing fluid in liquid state, the fluid being in a breathable gaseous; state when at standard temperature and pressure; a fluid flow member (16) secured within the garment (2) and coupled to the receptacle (6) for conducting the fluid in liquid state from the receptacle (6) to the interior of the garment (2); and a fluid flow control device (14) connected for causing fluid to flow from the receptacle (6) to the fluid flow member (16) at a rate determined by the breathable air requirement of the wearer, wherein fluid in liquid state is conducted into the interior of the garment (2) at a rate to be vaporized and heated to a breathable temperature by body heat produced by the wearer.

  11. Results from Carbon Dioxide Washout Testing Using a Suited Manikin Test Apparatus with a Space Suit Ventilation Test Loop

    NASA Technical Reports Server (NTRS)

    Chullen, Cinda; Conger, Bruce; McMillin, Summer; Vonau, Walt; Kanne, Bryan; Korona, Adam; Swickrath, Mike

    2016-01-01

    NASA is developing an advanced portable life support system (PLSS) to meet the needs of a new NASA advanced space suit. The PLSS is one of the most critical aspects of the space suit providing the necessary oxygen, ventilation, and thermal protection for an astronaut performing a spacewalk. The ventilation subsystem in the PLSS must provide sufficient carbon dioxide (CO2) removal and ensure that the CO2 is washed away from the oronasal region of the astronaut. CO2 washout is a term used to describe the mechanism by which CO2 levels are controlled within the helmet to limit the concentration of CO2 inhaled by the astronaut. Accumulation of CO2 in the helmet or throughout the ventilation loop could cause the suited astronaut to experience hypercapnia (excessive carbon dioxide in the blood). A suited manikin test apparatus (SMTA) integrated with a space suit ventilation test loop was designed, developed, and assembled at NASA in order to experimentally validate adequate CO2 removal throughout the PLSS ventilation subsystem and to quantify CO2 washout performance under various conditions. The test results from this integrated system will be used to validate analytical models and augment human testing. This paper presents the system integration of the PLSS ventilation test loop with the SMTA including the newly developed regenerative Rapid Cycle Amine component used for CO2 removal and tidal breathing capability to emulate the human. The testing and analytical results of the integrated system are presented along with future work.

  12. TR-BREATH: Time-Reversal Breathing Rate Estimation and Detection.

    PubMed

    Chen, Chen; Han, Yi; Chen, Yan; Lai, Hung-Quoc; Zhang, Feng; Wang, Beibei; Liu, K J Ray

    2018-03-01

    In this paper, we introduce TR-BREATH, a time-reversal (TR)-based contact-free breathing monitoring system. It is capable of breathing detection and multiperson breathing rate estimation within a short period of time using off-the-shelf WiFi devices. The proposed system exploits the channel state information (CSI) to capture the miniature variations in the environment caused by breathing. To magnify the CSI variations, TR-BREATH projects CSIs into the TR resonating strength (TRRS) feature space and analyzes the TRRS by the Root-MUSIC and affinity propagation algorithms. Extensive experiment results indoor demonstrate a perfect detection rate of breathing. With only 10 s of measurement, a mean accuracy of can be obtained for single-person breathing rate estimation under the non-line-of-sight (NLOS) scenario. Furthermore, it achieves a mean accuracy of in breathing rate estimation for a dozen people under the line-of-sight scenario and a mean accuracy of in breathing rate estimation of nine people under the NLOS scenario, both with 63 s of measurement. Moreover, TR-BREATH can estimate the number of people with an error around 1. We also demonstrate that TR-BREATH is robust against packet loss and motions. With the prevailing of WiFi, TR-BREATH can be applied for in-home and real-time breathing monitoring.

  13. Syllable-related breathing in infants in the second year of life.

    PubMed

    Parham, Douglas F; Buder, Eugene H; Oller, D Kimbrough; Boliek, Carol A

    2011-08-01

    This study explored whether breathing behaviors of infants within the 2nd year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Vocalizations and breathing kinematics of 9 infants between 53 and 90 weeks of age were recorded. A strict selection protocol was used to identify analyzable breath cycles. Syllables were categorized on the basis of consensus coding. Inspiratory and expiratory durations, excursions, and slopes were calculated for the 3 breath cycle types and were normalized using mean tidal breath measures. Tidal breathing cycles were significantly different from syllable-related cycles on all breathing measures. There were no significant differences between unarticulated syllable cycles and canonical syllable cycles, even after controlling for utterance duration and sound pressure level. Infants in the 2nd year of life exhibit clear differences between tidal breathing and speech-related breathing, but categorically distinct breath support for syllable types with varying articulatory demands was not evident in the present findings. Speech development introduces increasingly complex utterances, so older infants may produce detectable articulation-related adaptations of breathing kinematics. For younger infants, breath support may vary systematically among utterance types, due more to phonatory variations than to articulatory demands.

  14. Syllable-Related Breathing in Infants in the Second Year of Life

    PubMed Central

    Parham, Douglas F.; Buder, Eugene H.; Oller, D. Kimbrough; Boliek, Carol A.

    2010-01-01

    Purpose This study explored whether breathing behaviors of infants within the second year of life differ between tidal breathing and breathing supporting single unarticulated syllables and canonical/articulated syllables. Method Vocalizations and breathing kinematics of nine infants between 53 and 90 weeks of age were recorded. A strict selection protocol was used to identify analyzable breath cycles. Syllables were categorized based on consensus coding. Inspiratory and expiratory durations, excursions, and slopes were calculated for the three breath cycle types and normalized using mean tidal breath measures. Results Tidal breathing cycles were significantly different from syllable-related cycles on all breathing measures. There were no significant differences between unarticulated syllable cycles and canonical syllable cycles, even after controlling for utterance duration and sound pressure level. Conclusions Infants in the second year of life exhibit clear differences between tidal breathing and speech-related breathing, but categorically distinct breath support for syllable types with varying articulatory demands was not evident in the current findings. Speech development introduces increasingly complex utterances, so older infants may produce detectable articulation-related adaptations of breathing kinematics. For younger infants, breath support may vary systematically among utterance types, due more to phonatory variations than to articulatory demands. PMID:21173390

  15. Free-breathing quantification of hepatic fat in healthy children and children with nonalcoholic fatty liver disease using a multi-echo 3-D stack-of-radial MRI technique.

    PubMed

    Armstrong, Tess; Ly, Karrie V; Murthy, Smruthi; Ghahremani, Shahnaz; Kim, Grace Hyun J; Calkins, Kara L; Wu, Holden H

    2018-05-04

    In adults, noninvasive chemical shift encoded Cartesian magnetic resonance imaging (MRI) and single-voxel magnetic resonance (MR) spectroscopy (SVS) accurately quantify hepatic steatosis but require breath-holding. In children, especially young and sick children, breath-holding is often limited or not feasible. Sedation can facilitate breath-holding but is highly undesirable. For these reasons, there is a need to develop free-breathing MRI technology that accurately quantifies steatosis in all children. This study aimed to compare non-sedated free-breathing multi-echo 3-D stack-of-radial (radial) MRI versus standard breath-holding MRI and SVS techniques in a group of children for fat quantification with respect to image quality, accuracy and repeatability. Healthy children (n=10, median age [±interquartile range]: 10.9 [±3.3] years) and overweight children with nonalcoholic fatty liver disease (NAFLD) (n=9, median age: 15.2 [±3.2] years) were imaged at 3 Tesla using free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS. Acquisitions were performed twice to assess repeatability (within-subject mean difference, MD within ). Images and hepatic proton-density fat fraction (PDFF) maps were scored for image quality. Free-breathing and breath-holding PDFF were compared using linear regression (correlation coefficient, r and concordance correlation coefficient, ρ c ) and Bland-Altman analysis (mean difference). P<0.05 was considered significant. In patients with NAFLD, free-breathing radial MRI demonstrated significantly less motion artifacts compared to breath-holding Cartesian (P<0.05). Free-breathing radial PDFF demonstrated a linear relationship (P<0.001) versus breath-holding SVS PDFF and breath-holding Cartesian PDFF with r=0.996 and ρ c =0.994, and r=0.997 and ρ c =0.995, respectively. The mean difference in PDFF between free-breathing radial MRI, breath-holding Cartesian MRI and breath-holding SVS was <0.7%. Repeated free-breathing radial MRI had MD within =0.25% for PDFF. In this pediatric study, non-sedated free-breathing radial MRI provided accurate and repeatable hepatic PDFF measurements and improved image quality, compared to standard breath-holding MR techniques.

  16. Unmanned Evaluation of Six Closed-Circuit Oxygen Rebreathers.

    DTIC Science & Technology

    1982-07-01

    and the exhaled gas flows through the exhalation hose (8) to the CO2 scrubber (9); it is then drawn through the CO2 scrubber (9) with the next...and full inhalation cycles). 2. Canister Duration Tests: CO2 level out of scrubber expressed as percentage of SEV. D. Coinputed Parameters 1...comprehensive evaluation of commercial SCUBA regulators (reference 4) performed by NKDU in June 1979. *i Inadequate second stage venturi assist and

  17. Air Break During Preoxygenation and Risk of Altitude Decompression Sickness

    DTIC Science & Technology

    2010-10-01

    examination and were representative of the USAF rated aircrew popula- tion. They were not allowed to participate in scuba div- ing, hyperbaric exposures, or...subjects dur- ing the hypobaric exposures and the subjects were not questioned about how they felt during the altitude ex- posures. Each subject was...to consult with the physicians in Hyperbaric Medicine within the same building. Endpoints of the exposures were: 1) comple- tion of the scheduled

  18. The Effects of Teaching Coping Strategies on the Performance of Beginning Scuba Divers.

    DTIC Science & Technology

    1983-04-07

    Weinberg, R. S., 3nd jackson, A. Effects of practice and training of visuo-notor benavior rehearsal in Ienhancing karate Derformance. Paper...the event of physical injury resulting from this investigation, neither financial compensation nor free medical treatment is provided for such a...physical injury , and that further information on this policy is available from the Vice President for Research and Graduate Studies, 207 Old Main (865

  19. 'Weightless' acrylic painting by Jack Kroehnke

    NASA Technical Reports Server (NTRS)

    1987-01-01

    'Weightless' acrylic painting by Jack Kroehnke depicts STS-26 Discovery, Orbiter Vehicle (OV) 103, Mission Specialist (MS) David C. Hilmers participating in extravehicular activity (EVA) simulation in JSC Weightless Environment Training Facility (WETF) Bldg 29. In the payload bay (PLB) mockup, Hilmers, wearing extravehicular mobility unit (EMU), holds onto the mission-peculiar equipment support structure in foreground while SCUBA-equipped diver monitors activity overhead and camera operator records EVA procedures. Copyrighted art work for use by NASA.

  20. [Immersion pulmonary edema].

    PubMed

    Desgraz, Benoît; Sartori, Claudio; Saubade, Mathieu; Héritier, Francis; Gabus, Vincent

    2017-07-12

    Immersion pulmonary edema may occur during scuba diving, snorke-ling or swimming. It is a rare and often recurrent disease, mainly affecting individuals aged over 50 with high blood pressure. However it also occurs in young individuals with a healthy heart. The main symptoms are dyspnea, cough and hemoptysis. The outcome is often favorable under oxygen treatment but deaths are reported. A cardiac and pulmonary assessment is necessary to evaluate the risk of recurrence and possible contraindications to immersion.

Top