13. View northeast of boiler plant (Building 39), engineering work ...
13. View northeast of boiler plant (Building 39), engineering work order building/former tin shop (Building 129), laundry MAT workshop (Building 28), pipe shop/former water softening plant (Building 81), paint spray shop/former blacksmith shop (Building 95), fuel oil storage tank building (Building 103), mason's shop (Building 77), and carpenter shop (Building 97) with steel water tank (Building 124) in background - National Home for Disabled Volunteer Soldiers Western Branch, 4101 South Fourth Street, Leavenworth, Leavenworth County, KS
Brackney, Larry; Parker, Andrew; Long, Nicholas; Metzger, Ian; Dean, Jesse; Lisell, Lars
2016-04-12
A building energy analysis system includes a building component library configured to store a plurality of building components, a modeling tool configured to access the building component library and create a building model of a building under analysis using building spatial data and using selected building components of the plurality of building components stored in the building component library, a building analysis engine configured to operate the building model and generate a baseline energy model of the building under analysis and further configured to apply one or more energy conservation measures to the baseline energy model in order to generate one or more corresponding optimized energy models, and a recommendation tool configured to assess the one or more optimized energy models against the baseline energy model and generate recommendations for substitute building components or modifications.
11. GENERAL VIEW OF STATION 'L', LOOKING SOUTHWEST, BUILDINGS FROM ...
11. GENERAL VIEW OF STATION 'L', LOOKING SOUTHWEST, BUILDINGS FROM LEFT TO RIGHT: LINCOLN SUBSTATION (BUILDING L3), EQUIPMENT BUILDING (BUILDING K), H.P. BOILER ROOM (BUILDING L4), L.P. BOILER ROOM (BUILDING L2), BOILER #16 (BUILDING LB), POWERHOUSE EXTENSION (BUILDING L5), MACHINE SHOP (BUILDING L7) - Portland General Electric Company, Station "L", 1841 Southeast Water Street, Portland, Multnomah County, OR
3. Context view includes Building 78 (second from left) and ...
3. Context view includes Building 78 (second from left) and Building 59 (partially seen at right edge). Camera is pointed WSW along Farragut Avenue. Buildings on left side of street are, from left: Building 38, Building 78 and Building 431. Crane No. 80 is at Drydock No. 1. Buildings on right side of street are, from right: Building 59 (with porch posts) and Building 856 (two sections). - Puget Sound Naval Shipyard, Administration Building, Farragut Avenue, Bremerton, Kitsap County, WA
NASA Astrophysics Data System (ADS)
Latief, Yusuf; Berawi, Mohammed Ali; Basten, Van; Riswanto; Budiman, Rachmat
2017-07-01
Green building concept becomes important in current building life cycle to mitigate environment issues. The purpose of this paper is to optimize building construction performance towards green building premium cost, achieving green building rating tools with optimizing life cycle cost. Therefore, this study helps building stakeholder determining building fixture to achieve green building certification target. Empirically the paper collects data of green building in the Indonesian construction industry such as green building fixture, initial cost, operational and maintenance cost, and certification score achievement. After that, using value engineering method optimized green building fixture based on building function and cost aspects. Findings indicate that construction performance optimization affected green building achievement with increasing energy and water efficiency factors and life cycle cost effectively especially chosen green building fixture.
Green commercial building insurance in Malaysia
NASA Astrophysics Data System (ADS)
Yang, Yu Xin Ou; Chew, Boon Cheong; Loo, Heoy Shin; Tan, Lay Hong
2017-03-01
Green building construction is growing tremendously globally even in Malaysia. Currently, there are approximate 636 buildings have registered and to be certified with Green Building Index. Among these buildings, 45 buildings have already fulfilled the requirements and fully certified. The other buildings still under provisional certification stage. Malaysia had adopted Green Building Index in 2009 to support a move to promote green building concept. Malaysia starts to move towards green building because Malaysian construction and building industry realizes that both energy consumed and waste produced are reduced without irreversible impacts to ecosystems. Consequently, insurance companies such as Fireman's Fund from America has started the green building insurance policies for their green building in the year of 2006, while Malaysia still remain the coverage for green buildings using conventional property insurance. There are lacks of efforts to be seen from insurance companies to propose green building insurance for these green buildings. There are a few factors which can take into consideration for insurance companies to start the very first green building insurance in Malaysia. Although there are challenges, some efficient strategies have been identified to overcome the problems. The methods used in this research topic is qualitative research. The results obtained shows that green commercial building insurance has a huge business opportunity in Malaysia because the number of green commercial buildings are increasing tremendously in Malaysia. It is a favor to implement green building insurance in Malaysia. Furthermore, insurance companies can consider to add in extra coverage in standard building policy to provide extra protection for non-certified green buildings which have the intention to rebuilt in green when damage happens. Generally, it is very important to introduce green commercial buildings insurance into Malaysia so that all of the green commercial buildings can be fully covered.
Zhang, Pei-feng; Hu, Yuan-man; He, Hong-shi; Xiong, Zai-ping; Liu, Miao
2010-12-01
In this paper, three-dimensional building information was extracted from high resolution satellite image based on Barista software. Combined with ArcGIS software, the dynamic changes of the building landscape in Tiexi District of Shenyang City during urban renewal process were analyzed from the conversion contribution rate, building density, average building height, and built-up area rate. It was found that during this urban renewal process, four dominant landscape types (vacant lot, residential building, industrial building, and road) were the main parts of the landscape changes. The areas of vacant lot, residential building, commercial building, and road increased, while that of industrial building decreased. The building density decreased, while the average building height increased. There was an obvious regional variation in building landscape. The building density in industrial district was higher than that in residential district, while the average building height was in adverse. The further from the city center, the lower the building density and building average height.
12. VIEW OF SOUTH ELEVATIONS OF BUILDINGS 7, 8, 48, ...
12. VIEW OF SOUTH ELEVATIONS OF BUILDINGS 7, 8, 48, 50, 40, 39 AND 33; BUILDING 7 AT EXTREME LEFT CENTER, BUILDING 8 LEFT CENTER FOREGROUND; BUILDING 48 LEFT CENTER BACKGROUND; BUILDING 50 CENTER FOREGROUND; BUILDING 40 CENTER BACKGROUND; BUILDING 39 RIGHT FOREGROUND; BUILDING 33 RIGHT BACKGROUND - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
1. Context view includes Building 59 (second from left). Camera ...
1. Context view includes Building 59 (second from left). Camera is pointed ENE along Farragut Aveune. Buildings on left side of street are, from left: Building 856, Building 59 and Building 107. On right side of street they are, from right; Building 38, Building 452 and Building 460. - Puget Sound Naval Shipyard, Pattern Shop, Farragut Avenue, Bremerton, Kitsap County, WA
GENERAL VIEW OF FLIGHT LINE BUILDINGS. FROM RIGHT TO LEFT, ...
GENERAL VIEW OF FLIGHT LINE BUILDINGS. FROM RIGHT TO LEFT, PETROLEUM OPERATIONS BUILDING (BUILDING, 2840), SECURITY POLICE CENTRAL CONTROL BUILDING (BUILDING 2841). MAINTENANCE DOCK (BUILDING 2837) AND MAINTENANCE DOCK (BUILDING 2890). VIEW TO NORTHWEST - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY
NASA Astrophysics Data System (ADS)
Zhang, Jun; Li, Ri Yi
2018-06-01
Building energy simulation is an important supporting tool for green building design and building energy consumption assessment, At present, Building energy simulation software can't meet the needs of energy consumption analysis and cabinet level micro environment control design of prefabricated building. thermal physical model of prefabricated building is proposed in this paper, based on the physical model, the energy consumption calculation software of prefabricated cabin building(PCES) is developed. we can achieve building parameter setting, energy consumption simulation and building thermal process and energy consumption analysis by PCES.
Methodology to Assess No Touch Audit Software Using Simulated Building Utility Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheung, Howard; Braun, James E.; Langner, M. Rois
This report describes a methodology developed for assessing the performance of no touch building audit tools and presents results for an available tool. Building audits are conducted in many commercial buildings to reduce building energy costs and improve building operation. Because the audits typically require significant input obtained by building engineers, they are usually only affordable for larger commercial building owners. In an effort to help small building and business owners gain the benefits of an audit at a lower cost, no touch building audit tools have been developed to remotely analyze a building's energy consumption.
49 CFR 41.110 - New DOT owned buildings and additions to buildings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 1 2010-10-01 2010-10-01 false New DOT owned buildings and additions to buildings....110 New DOT owned buildings and additions to buildings. (a) DOT Operating Administrations responsible for the design and construction of new DOT Federally owned buildings will ensure that each building is...
Mountain campus is designed to meet the Gold or Platinum standards of the U.S. Green Building Council's Research Facility. South Site Entrance Building South Site Entrance Building 2013 U.S. Green Buildings Building Awards Building Awards NREL's high-performance buildings are sustainability models for the
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Tan, Qing; Evans, Meredydd
India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, buildingmore » energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.« less
WEAPONS STORAGE AREA, LOOKING TOWARD ELECTRIC POWER STATION BUILDING (BUILDING ...
WEAPONS STORAGE AREA, LOOKING TOWARD ELECTRIC POWER STATION BUILDING (BUILDING 3583), STORAGE BUILDING (BUILDING 3584)NIGHT AND SECURITY POLICE ENTRY CONTROL (BUILDING 3582)LEFT. VIEW TO NORTHEAST - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY
Scalable Deployment of Advanced Building Energy Management Systems
2013-06-01
Building Automation and Control Network BDAS Building Data Acquisition System BEM building energy model BIM building information modeling BMS...A prototype toolkit to seamlessly and automatically transfer a Building Information Model ( BIM ) to a Building Energy Model (BEM) has been...circumvent the need to manually construct and maintain a detailed building energy simulation model . This detailed
22. AERIAL VIEW LOOKING EAST DOWN CENTRAL AVENUE FROM WEST ...
22. AERIAL VIEW LOOKING EAST DOWN CENTRAL AVENUE FROM WEST OF THE ADMINISTRATIVE AND SUPPORT AREA OF THE PLANT. ON THE LEFT (NORTH) SIDE OF THE STREET IN THE FOREGROUND OF THE PHOTOGRAPH IS BUILDING 111, THE GENERAL ADMINISTRATION BUILDING. TO THE EAST OF BUILDING 111 IS BUILDING 112, THE CAFETERIA. FURTHER TO THE EAST IS BUILDING 331, THE VEHICLE MAINTENANCE GARAGE AND FIRE DEPARTMENT; BUILDING 333, THE PAINT SHOP; BUILDING 334, THE ELECTRICAL AND GENERAL MAINTENANCE SHOP; AND BUILDING 551, THE GENERAL WAREHOUSE. ON THE RIGHT (SOUTH) SIDE OF CENTRAL AVENUE, IN THE FOREGROUND IS BUILDING 121, FIREARMS REPAIR. BEHIND BUILDING 121 IS BUILDING 122, EMERGENCY MEDICAL SERVICES, AND BUILDING 123, HEALTH PHYSICS LABORATORY. BUILDING 441, THE PRODUCTION ... - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
Life cycle assessment: Existing building retrofit versus replacement
NASA Astrophysics Data System (ADS)
Darabi, Nura
The embodied energy in building materials constitutes a large part of the total energy required for any building (Thormark 2001, 429). In working to make buildings more energy efficient this needs to be considered. Integrating considerations about life cycle assessment for buildings and materials is one promising way to reduce the amount of energy consumption being used within the building sector and the environmental impacts associated with that energy. A life cycle assessment (LCA) model can be utilized to help evaluate the embodied energy in building materials in comparison to the buildings operational energy. This thesis takes into consideration the potential life cycle reductions in energy and CO2 emissions that can be made through an energy retrofit of an existing building verses demolition and replacement with a new energy efficient building. A 95,000 square foot institutional building built in the 1960`s was used as a case study for a building LCA, along with a calibrated energy model of the existing building created as part of a previous Masters of Building Science thesis. The chosen case study building was compared to 10 possible improvement options of either energy retrofit or replacement of the existing building with a higher energy performing building in order to see the life cycle relationship between embodied energy, operational energy, and C02 emissions. As a result of completing the LCA, it is shown under which scenarios building retrofit saves more energy over the lifespan of the building than replacement with new construction. It was calculated that energy retrofit of the chosen existing institutional building would reduce the amount of energy and C02 emissions associated with that building over its life span.
A long-term, integrated impact assessment of alternative building energy code scenarios in China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Eom, Jiyong; Evans, Meredydd
2014-04-01
China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, ismore » developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13% - 22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement.« less
Commercial Buildings Energy Consumption Survey (CBECS)
2028-01-01
The Commercial Buildings Energy Consumption Survey (CBECS) is a national sample survey that collects information on the stock of U.S. commercial buildings, including their energy-related building characteristics and energy usage data (consumption and expenditures). Commercial buildings include all buildings in which at least half of the floorspace is used for a purpose that is not residential, industrial, or agricultural. By this definition, CBECS includes building types that might not traditionally be considered commercial, such as schools, hospitals, correctional institutions, and buildings used for religious worship, in addition to traditional commercial buildings such as stores, restaurants, warehouses, and office buildings.
9. Building 105, Facilities Engineering Building, 1830, interior, Tin Metal ...
9. Building 105, Facilities Engineering Building, 1830, interior, Tin Metal area of building, looking S. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY
5. VIEW SOUTH FROM BUILDING 20 OF BUILDINGS 4, 3 ...
5. VIEW SOUTH FROM BUILDING 20 OF BUILDINGS 4, 3 AND 2; BUILDING 4 AT EXTREME LEFT CENTER; RUNDBOGENSTIL TOWER AT LEFT CENTER; BUILDING 3 AT CENTER; BUILDING 2 RIGHT OF CENTER AND '1876' STACK AT EXTREME RIGHT - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
10. Building 105, Facilities Engineering Building, 1830, interior, air condition ...
10. Building 105, Facilities Engineering Building, 1830, interior, air condition repair shop, S end of building, looking N. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY
8. Building 105, Facilities Engineering Building, 1830, interior, drafting area, ...
8. Building 105, Facilities Engineering Building, 1830, interior, drafting area, east side of building, center, looking N. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY
Statistical distribution of building lot frontage: application for Tokyo downtown districts
NASA Astrophysics Data System (ADS)
Usui, Hiroyuki
2018-03-01
The frontage of a building lot is the determinant factor of the residential environment. The statistical distribution of building lot frontages shows how the perimeters of urban blocks are shared by building lots for a given density of buildings and roads. For practitioners in urban planning, this is indispensable to identify potential districts which comprise a high percentage of building lots with narrow frontage after subdivision and to reconsider the appropriate criteria for the density of buildings and roads as residential environment indices. In the literature, however, the statistical distribution of building lot frontages and the density of buildings and roads has not been fully researched. In this paper, based on the empirical study in the downtown districts of Tokyo, it is found that (1) a log-normal distribution fits the observed distribution of building lot frontages better than a gamma distribution, which is the model of the size distribution of Poisson Voronoi cells on closed curves; (2) the statistical distribution of building lot frontages statistically follows a log-normal distribution, whose parameters are the gross building density, road density, average road width, the coefficient of variation of building lot frontage, and the ratio of the number of building lot frontages to the number of buildings; and (3) the values of the coefficient of variation of building lot frontages, and that of the ratio of the number of building lot frontages to that of buildings are approximately equal to 0.60 and 1.19, respectively.
Building Inventory Database on the Urban Scale Using GIS for Earthquake Risk Assessment
NASA Astrophysics Data System (ADS)
Kaplan, O.; Avdan, U.; Guney, Y.; Helvaci, C.
2016-12-01
The majority of the existing buildings are not safe against earthquakes in most of the developing countries. Before a devastating earthquake, existing buildings need to be assessed and the vulnerable ones must be determined. Determining the seismic performance of existing buildings which is usually made with collecting the attributes of existing buildings, making the analysis and the necessary queries, and producing the result maps is very hard and complicated procedure that can be simplified with Geographic Information System (GIS). The aim of this study is to produce a building inventory database using GIS for assessing the earthquake risk of existing buildings. In this paper, a building inventory database for 310 buildings, located in Eskisehir, Turkey, was produced in order to assess the earthquake risk of the buildings. The results from this study show that 26% of the buildings have high earthquake risk, 33% of the buildings have medium earthquake risk and the 41% of the buildings have low earthquake risk. The produced building inventory database can be very useful especially for governments in dealing with the problem of determining seismically vulnerable buildings in the large existing building stocks. With the help of this kind of methods, determination of the buildings, which may collapse and cause life and property loss during a possible future earthquake, will be very quick, cheap and reliable.
3. ROADWAY TO THE SOUTH OF BUILDING NO. 1. AT ...
3. ROADWAY TO THE SOUTH OF BUILDING NO. 1. AT FAR LEFT IS THE SHADOW OF BUILDING NO. 6 (WAREHOUSE). ALSO VISIBLE AT THE LEFT IS BUILDING NO. 4 (BOILER HOUSE), BUILDING NO. 3 (GATE HOUSE), AND BUILDING NO. 2 (OFFICE BUILDING). IN THE RIGHT FOREGROUND IS BUILDING NO. 10 (ELECTRICAL SERVICES AND SWITCHING STATION). - United Engineering Company Shipyard, 2900 Main Street, Alameda, Alameda County, CA
Small- and Medium-Sized Commercial Building Monitoring and Controls Needs: A Scoping Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katipamula, Srinivas; Underhill, Ronald M.; Goddard, James K.
2012-10-31
Buildings consume over 40% of the total energy consumption in the U.S. A significant portion of the energy consumed in buildings is wasted because of the lack of controls or the inability to use existing building automation systems (BASs) properly. Much of the waste occurs because of our inability to manage and controls buildings efficiently. Over 90% of the buildings are either small-size (<5,000 sf) or medium-size (between 5,000 sf and 50,000 sf); these buildings currently do not use BASs to monitor and control their building systems from a central location. According to Commercial Building Energy Consumption Survey (CBECS), aboutmore » 10% of the buildings in the U.S. use BASs or central controls to manage their building system operations. Buildings that use BASs are typically large (>100,000 sf). Lawrence Berkeley National Laboratory (LBNL), Oak Ridge National Laboratory (ORNL) and Pacific Northwest National Laboratory (PNNL) were asked by the U.S. Department of Energy’s (DOE’s) Building Technologies Program (BTP) to identify monitoring and control needs for small- and medium-sized commercial buildings and recommend possible solutions. This study documents the needs and solutions for small- and medium-sized buildings.« less
Building No. 5, Main Building; Building NO. 9, Guard House ...
Building No. 5, Main Building; Building NO. 9, Guard House (left). Viewed from across corner Lakeside Avenue and Main Street - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
2. PRINTING AND ADVERTISING BUILDING, ADMINISTRATION BUILDING, MERCHANDISE BUILDING, AND ...
2. PRINTING AND ADVERTISING BUILDING, ADMINISTRATION BUILDING, MERCHANDISE BUILDING, AND GARDEN, VIEW TO SOUTHWEST - Sears Roebuck & Company Mail Order Plant, Bounded by Lexington & Grenshaw Streets, Kedzie Avenue & Independence Boulevard, Chicago, Cook County, IL
Commercial Buildings Energy Consumption Survey - Office Buildings
2010-01-01
Provides an in-depth look at this building type as reported in the 2003 Commercial Buildings Energy Consumption Survey. Office buildings are the most common type of commercial building and they consumed more than 17% of all energy in the commercial buildings sector in 2003. This special report provides characteristics and energy consumption data by type of office building (e.g. administrative office, government office, medical office) and information on some of the types of equipment found in office buildings: heating and cooling equipment, computers, servers, printers, and photocopiers.
Third of three panoramic views of North Base as seen ...
Third of three panoramic views of North Base as seen from top of Building 4500, Control Tower. View looks west (268°) at ancillary structures surrounding Building 4505. In immediate foreground is Building 4499 Loading Ramp. To the far upper left is Building 4497 Guard House, adjacent to Building 4496 Security Facility. At the extreme right of the view is the chimney and western corner of Building 4505 to which is attached a large light-colored wing used as offices and workspaces; to the immediate southwest of this wing stands Building 4498 Supply Warehouse. In the background, just above Building 4498 in view, stands Building 4494 Cafeteria. The round drum to the right of Building 4494 is Building 4503, a 500,000 gallon water tank which supplies the firefighting system; to the immediate right of the tank is Building 4504 Deluge Water Pumping Station which contains large pumps for firefighting. Just visible above the water tank is Building 4493 Gymnasium. - Edwards Air Force Base, North Base, North Base Road, Boron, Kern County, CA
Seismic responses of two adjacent buildings. I. Data and analyses
Çelebi, Mehmet
1993-01-01
In this two-part paper, responses of two, adjacent, seven-story buildings in Norwalk, California, to the Whittier-Narrows, Calif, earthquake of Oct. 1, 1987 are studied. Building A, instrumented according to code recommendations, and building B, extensively instrumented, are offset by 16.3 m from one another. The data set includes motions from the superstructure of both buildings, from a downhole below the foundation of building B, and from three free-field sites. Part I of the paper includes descriptions of the buildings, site, instrumentation, and analysis of the data of each building. System identification and spectral analysis techniques are employed in part I. Building A has identical first-mode frequencies of 0.65 Hz for both building axes. The strong-motion response characteristics of building A are considerably different than those determined from low-amplitude tests. Building B has fundamental modes at 0.76 Hz and 0.83 Hz in the major and minor axes, respectively. Torsional and diaphragm effects in building B are negligible.
Building No. 1, left; Building No. 9, Guard House, center; ...
Building No. 1, left; Building No. 9, Guard House, center; Building No. 5, Main Building, right. View from across Main Street - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
2. SITE BUILDING 002 SCANNER BUILDING VIEW IS ...
2. SITE BUILDING 002 - SCANNER BUILDING - VIEW IS LOOKING NORTH 80° WEST "B" FACE ALONG BUILDING "A" FACE. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
1. SOUTH FRONT OF TURBINE BUILDING BUILDING L1 (LEFT) AND ...
1. SOUTH FRONT OF TURBINE BUILDING BUILDING L1 (LEFT) AND OF L.P. BOILER ROOM BUILDING L2 (RIGHT) - Portland General Electric Company, Turbine Building, 1841 Southeast Water Street, Portland, Multnomah County, OR
Green Building Premium Cost Analysis in Indonesia Using Work Breakdown Structure Method
NASA Astrophysics Data System (ADS)
Basten, V.; Latief, Y.; Berawi, M. A.; Riswanto; Muliarto, H.
2018-03-01
The concept of green building in the construction industry is indispensable for mitigating environmental issues such as waste, pollution, and carbon emissions. There are some countries that have Green Building rating tools. Indonesia particularly is the country which has Greenship rating tools but the number of Green Building is relatively low. Development of building construction is depended on building investors or owner initiation, so this research is conducted to get the building aspects that have significant effect on the attractiveness using The Green Building Concept. The method in this research is work breakdown structure method that detailing the green building activities. The particular activities will be processed to get the cost elements for the green building achievement that it was targeted to improve better than conventional building. The final result of the study was a very significant work package on green building construction in the city of Indonesia case study.
BUILDING 122 CONTAINS THREE GENERAL AREAS: OFFICE AREAS, INTERNAL DOSIMETRY, ...
BUILDING 122 CONTAINS THREE GENERAL AREAS: OFFICE AREAS, INTERNAL DOSIMETRY, AND MEDICAL/HEALTH. BUILDING 122 SHARES A COMMON WALL WITH BUILDING 121, THE PLANT SECURITY BUILDING. THE TWO-STORY BUILDING IN THE BACKGROUND IS BUILDING 111. (9/26/52) - Rocky Flats Plant, Emergency Medical Services Facility, Southwest corner of Central & Third Avenues, Golden, Jefferson County, CO
VIEW SOUTH FROM HAMILTON AVENUE BUILDING 25 LEFT; BUILDING 32 ...
VIEW SOUTH FROM HAMILTON AVENUE BUILDING 25 LEFT; BUILDING 32 MACHINE SHOP (1890) LEFT CENTER BUILDING 31 RIGGER'S SHOP (1890) CENTER BUILDING 28 BLACKSMITH SHOP (1885) RIGHT CENTER; BUILDING 27 PATTERN SHOP (1853) RIGHT - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
19. VIEW NORTHWEST OF ELEVATIONS OF BUILDINGS 22, 52 AND ...
19. VIEW NORTHWEST OF ELEVATIONS OF BUILDINGS 22, 52 AND 55; BUILDING 22 AT LEFT CENTER; COVERED WALKWAY TO BUILDING 40 IS AT RIGHT CENTER; BUILDING 52 RIGHT MID-CENTER BACKGROUND; BUILDING 55 CONNECTS BUILDING 52 AND 49A IN LEFT CENTER BACKGROUND - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
VIEW LOOKING SOUTHWEST AT BUILDING 121, THE PLANT SECURITY BUILDING. ...
VIEW LOOKING SOUTHWEST AT BUILDING 121, THE PLANT SECURITY BUILDING. BUILDING 121 WAS ONE OF THE ORIGINAL STRUCTURES AT THE ROCKY FLATS PLANT. IT SHARES A COMMON WALL WITH BUILDING 122, THE EMERGENCY MEDICAL BUILDING. (7/29/52) - Rocky Flats Plant, Security & Armory, West of Third Street, south of Central Avenue, Golden, Jefferson County, CO
13. Building 105, Facilities Engineering Building, 1830, interior, tin metal ...
13. Building 105, Facilities Engineering Building, 1830, interior, tin metal shop area, showing construction of window and part of ceiling, E wall of building. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY
Complex analysis of energy efficiency in operated high-rise residential building: Case study
NASA Astrophysics Data System (ADS)
Korniyenko, Sergey
2018-03-01
Energy conservation and human thermal comfort enhancement in buildings is a topical issue of modern architecture and construction. The innovative solution of this problem makes it possible to enhance building ecological and maintenance safety, to reduce hydrocarbon fuel consumption, and to improve life standard of people. The requirements to increase of energy efficiency in buildings should be provided at all the stages of building's life cycle that is at the stage of design, construction and maintenance of buildings. The research purpose is complex analysis of energy efficiency in operated high-rise residential building. Many actions for building energy efficiency are realized according to the project; mainly it is the effective building envelope and engineering systems. Based on results of measurements the energy indicators of the building during annual period have been calculated. The main reason of increase in heat losses consists in the raised infiltration of external air in the building through a building envelope owing to the increased air permeability of windows and balcony doors (construction defects). Thermorenovation of the building based on ventilating and infiltration heat losses reduction through a building envelope allows reducing annual energy consumption. Energy efficiency assessment based on the total annual energy consumption of building, including energy indices for heating and a ventilation, hot water supply and electricity supply, in comparison with heating is more complete. The account of various components in building energy balance completely corresponds to modern direction of researches on energy conservation and thermal comfort enhancement in buildings.
Country Report on Building Energy Codes in Australia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shui, Bin; Evans, Meredydd; Somasundaram, Sriram
2009-04-02
This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Australia, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Australia.
Li, Wenliang; Zhou, Yuyu; Cetin, Kristen S.; ...
2018-03-24
Urban buildings account for up to 75% of total energy use in the United States (U.S.). Understanding urban building energy use is important for developing feasible options to mitigate energy use and greenhouse gas emissions. In this study, an improved bottom-up building energy use model, named City Building Energy Use Model (CityBEUM), was developed to estimate building energy use for all buildings in Polk County, Iowa. First, 28 commercial and 6 residential building prototypes were designed by combing Assessor's parcel data and building footprint data. Then, the EnergyPlus in the CityBEUM was calibrated for all building prototypes using the U.S.more » Energy Information Administration's survey data, monthly utility meter data, and actual weather data. Finally, spatial and temporal variations of building energy use in the study area were estimated using the CityBEUM. Results indicate that the spatial variation of building energy use in the study area can be captured using the CityBEUM. With the monthly-calibrated model, the temporal pattern of urban building energy use can be well represented. The comparison of building energy use using the Typical Meteorological Year and actual weather data demonstrates the importance of using actual weather data in building energy modeling for an improved temporal representation.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Wenliang; Zhou, Yuyu; Cetin, Kristen S.
Urban buildings account for up to 75% of total energy use in the United States (U.S.). Understanding urban building energy use is important for developing feasible options to mitigate energy use and greenhouse gas emissions. In this study, an improved bottom-up building energy use model, named City Building Energy Use Model (CityBEUM), was developed to estimate building energy use for all buildings in Polk County, Iowa. First, 28 commercial and 6 residential building prototypes were designed by combing Assessor's parcel data and building footprint data. Then, the EnergyPlus in the CityBEUM was calibrated for all building prototypes using the U.S.more » Energy Information Administration's survey data, monthly utility meter data, and actual weather data. Finally, spatial and temporal variations of building energy use in the study area were estimated using the CityBEUM. Results indicate that the spatial variation of building energy use in the study area can be captured using the CityBEUM. With the monthly-calibrated model, the temporal pattern of urban building energy use can be well represented. The comparison of building energy use using the Typical Meteorological Year and actual weather data demonstrates the importance of using actual weather data in building energy modeling for an improved temporal representation.« less
Within compound, from Guard Tower (Building 5762), looking southwest, Technical ...
Within compound, from Guard Tower (Building 5762), looking southwest, Technical Equipment Building (Building 5760) to left, Microwave Tower (associated with Building 5769) and Civil Engineering Storage Building (Building 5766) to left - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA
University building safety index measurement using risk and implementation matrix
NASA Astrophysics Data System (ADS)
Rahman, A.; Arumsari, F.; Maryani, A.
2018-04-01
Many high rise building constructed in several universities in Indonesia. The high-rise building management must provide the safety planning and proper safety equipment in each part of the building. Unfortunately, most of the university in Indonesia have not been applying safety policy yet and less awareness on treating safety facilities. Several fire accidents in university showed that some significant risk should be managed by the building management. This research developed a framework for measuring the high rise building safety index in university The framework is not only assessed the risk magnitude but also designed modular building safety checklist for measuring the safety implementation level. The safety checklist has been developed for 8 types of the university rooms, i.e.: office, classroom, 4 type of laboratories, canteen, and library. University building safety index determined using risk-implementation matrix by measuring the risk magnitude and assessing the safety implementation level. Building Safety Index measurement has been applied in 4 high rise buildings in ITS Campus. The building assessment showed that the rectorate building in secure condition and chemical department building in beware condition. While the library and administration center building was in less secure condition.
An international survey of building energy codes and their implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, andmore » geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
INTEGRATING HEALTH INTO BUILDINGS OF THE FUTURE.
Heidari, Leila; Younger, Margalit; Chandler, George; Gooch, James; Schramm, Paul
2016-01-01
The health and wellbeing of building occupants should be a key priority in the design, building, and operation of new and existing buildings. Buildings can be designed, renovated, and constructed to promote healthy environments and behaviors and mitigate adverse health outcomes. This paper highlights health in terms of the relationship between occupants and buildings, as well as the relationship of buildings to the community. In the context of larger systems, smart buildings and green infrastructure strategies serve to support public health goals. At the level of the individual building, interventions that promote health can also enhance indoor environmental quality and provide opportunities for physical activity. Navigating the various programs that use metrics to measure a building's health impacts reveals that there are multiple co-benefits of a "healthy building," including those related to the economy, environment, society, transportation, planning, and energy efficiency.
14. Building 105, Facilities Engineering Building, 1830, interior, 1st floor, ...
14. Building 105, Facilities Engineering Building, 1830, interior, 1st floor, crib area of building, showing electrical and plumbing cribs, wall and ceiling detail, looking S. - Watervliet Arsenal, Building 105, South Broadway, on Hudson River, Watervliet, Albany County, NY
Building Better Buildings: Sustainable Building Activities in California Higher Education Systems.
ERIC Educational Resources Information Center
Sowell, Arnold; Eichel, Amanda; Alevantis, Leon; Lovegreen, Maureen
2003-01-01
This article outlines the activities and recommendations of California's sustainable building task force, discusses sustainable building activities in California's higher education systems, and highlights key issues that California is grappling with in its implementation of sustainable building practices. (EV)
ETR COMPLEX. CAMERA FACING SOUTH. FROM BOTTOM OF VIEW TO ...
ETR COMPLEX. CAMERA FACING SOUTH. FROM BOTTOM OF VIEW TO TOP: MTR, MTR SERVICE BUILDING, ETR CRITICAL FACILITY, ETR CONTROL BUILDING (ATTACHED TO ETR), ETR BUILDING (HIGH-BAY), COMPRESSOR BUILDING (ATTACHED AT LEFT OF ETR), HEAT EXCHANGER BUILDING (JUST BEYOND COMPRESSOR BUILDING), COOLING TOWER PUMP HOUSE, COOLING TOWER. OTHER BUILDINGS ARE CONTRACTORS' CONSTRUCTION BUILDINGS. INL NEGATIVE NO. 56-4105. Unknown Photographer, ca. 1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
The effect of building façade on natural lighting (Case study: Building of phinisi tower UNM)
NASA Astrophysics Data System (ADS)
Jamala, Nurul
2017-04-01
Utilization of natural lighting is one factor to lower the energy consumption of a building. Model building facade effect on natural light sources that can be absorbed into the building. UNM Phinisi Tower Building is a metaphor for the display of boats phinisi using Hiperbolic paraboloid facade which is futuristic sophistication of the application of science and technology, so that this object that is the focus of research on the effects on the building facade natural lighting. A quantitative research methods using Autodesk Echotech program to determine the value of the building into the natural lighting illuminance, either by using the facade and do not. The aim of research is to determine the percentage utilization of natural light into the building using a building facade. The study concluded the decline percentage in the value of the illuminance after the building using the building facade is 49% -74% and a mean value of 60.3%, so it can be concluded that the building facade effects on the natural lighting.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper willmore » describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.« less
Distribution trend of high-rise buildings worldwide and factor exploration
NASA Astrophysics Data System (ADS)
Yu, Shao-Qiao
2017-08-01
This paper elaborates the development phenomenon of high-rise buildings nowadays. The development trend of super high-rise buildings worldwide is analyzed based on data from the Council on Tall Buildings and Urban Habitat, taking the top 100 high-rise buildings in different continents and with the time development and building type as the objects. Through analysis, the trend of flourishing of UAE super high-rise buildings and stable development of European and American high-rise buildings is obtained. The reasons for different development degrees of the regions are demonstrated from the aspects of social development, economy, culture and consciousness. This paper also presents unavoidable issues of super high-rise buildings and calls for rational treatment to these buildings.
GENERAL VIEW OF FLIGHT LINE BUILDINGS. FROM LEFT TO RIGHT, ...
GENERAL VIEW OF FLIGHT LINE BUILDINGS. FROM LEFT TO RIGHT, JET ENGINE TEST CELL BUILDING (BUILDING 2820), MAINTENANCE DOCK, FLIGHT SYSTEM (BUILDING 2818)" AND MAINTENANCE DOCK (BUILDING 2793). VIEW TO SOUTHEAST - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-13
... construction (NAICS code 236), e.g., commercial building construction, industrial building construction, commercial and institutional building construction, building finishing contractors, drywall and insulation... Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings; Notice of Public...
Building Damage Extraction Triggered by Earthquake Using the Uav Imagery
NASA Astrophysics Data System (ADS)
Li, S.; Tang, H.
2018-04-01
When extracting building damage information, we can only determine whether the building is collapsed using the post-earthquake satellite images. Even the satellite images have the sub-meter resolution, the identification of slightly damaged buildings is still a challenge. As the complementary data to satellite images, the UAV images have unique advantages, such as stronger flexibility and higher resolution. In this paper, according to the spectral feature of UAV images and the morphological feature of the reconstructed point clouds, the building damage was classified into four levels: basically intact buildings, slightly damaged buildings, partially collapsed buildings and totally collapsed buildings, and give the rules of damage grades. In particular, the slightly damaged buildings are determined using the detected roof-holes. In order to verify the approach, we conduct experimental simulations in the cases of Wenchuan and Ya'an earthquakes. By analyzing the post-earthquake UAV images of the two earthquakes, the building damage was classified into four levels, and the quantitative statistics of the damaged buildings is given in the experiments.
View looking southeast from the roof of OSW Building, toward ...
View looking southeast from the roof of OSW Building, toward E Building (center ground of image). Part of H Building is in the immediate foreground. This photograph shows the relationship between E Building and others adjacent to it as well as some of the panorama of the site - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH
Water Consumption in Large Buildings Summary, 2012 CBECS
2017-01-01
Using water consumption data from the Commercial Buildings Energy Consumption Survey (CBECS), EIA estimates that the 46,000 large commercial buildings (greater than 200,000 square feet) used about 359 billion gallons of water (980 million gallons per day) in 2012. On average, these buildings used 7.9 million gallons per building, 20 gallons per square foot, and 18,400 gallons per worker in 2012. The types of buildings that are the most intensive water users are inpatient healthcare buildings, public order and safety buildings (which include prisons) and lodging buildings (which include hotels). For the second time in its history, EIA has collected water usage data through the CBECS.
11. AERIAL VIEW LOOKING NORTH AT THE BUILDING 800 ...
11. AERIAL VIEW LOOKING NORTH AT THE BUILDING 800 - AREA COMPLEX. ENRICHED URANIUM COMPONENTS WERE MANUFACTURED IN THIS AREA OF THE SITE. BUILDING 881, IN THE RIGHT FOREGROUND OF THE PHOTOGRAPH, WAS THE ORIGINAL PLANT B. BUILDING 883, USED FOR ROLLING AND FORMING URANIUM COMPONENTS, IS DIRECTLY TO THE NORTH OF BUILDING 881. TO THE EAST OF BUILDING 883 IS BUILDING 885, A RESEARCH AND DEVELOPMENT FACILITY FOR ALLOYS AND NON-PLUTONIUM METALS. IN THE FOREGROUND TO THE WEST OF BUILDING 881 IS AN OFFICE BUILDING, 850 (6/7/90). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
General view of buildings: Building No. 6 with smokestack (left ...
General view of buildings: Building No. 6 with smokestack (left foreground); Building No. 5 (left background); Base of Water Tower (right foreground); Buildings 4, 3, 2, 1 (center foreground to background) - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
Federal Register 2010, 2011, 2012, 2013, 2014
2012-07-23
... Federal High-Performance Green Buildings; Federal Buildings Personnel Training Act; Notification of... High- Performance Green Buildings, Office of Governmentwide Policy, General Services Administration... download from the Office of Federal High-Performance Green Building Web site Library at-- http://www.gsa...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-01-17
... Federal High-Performance Green Buildings; the Green Building Advisory Committee; Notification of Upcoming... teleconference meetings of the Green Building Advisory Committee (the Committee). The teleconference meetings are... Federal High Performance Green Buildings, Office of Governmentwide Policy, General Services Administration...
2. Building 22 south elevation oblique. Ghost of Building 22A ...
2. Building 22 south elevation oblique. Ghost of Building 22A visible on south elevation. South elevation of Building 22A in foreground. View looking NW. - John & James Dobson Carpet Mill (West Parcel), Building No. 22, 4041-4055 Ridge Avenue, Philadelphia, Philadelphia County, PA
Credit BG. View looks north northwest (325°) towards Administration Building ...
Credit BG. View looks north northwest (325°) towards Administration Building across aircraft apron east of Building 4505. Building 4507 (Storage Building) appears at extreme right of view - Edwards Air Force Base, North Base, Administration Building, Northeast of A Street, Boron, Kern County, CA
WEAPONS STORAGE AREA. FROM RIGHT TO LEFT, ABOVEGROUND STORAGE MAGAZINE ...
WEAPONS STORAGE AREA. FROM RIGHT TO LEFT, ABOVEGROUND STORAGE MAGAZINE (BUILDING 3568), SPARES INERT STORAGE BUILDING (BUILDING 3570), MISSILE ASSEMBLY SHOP (BUILDING 3578) AND SEGREGATED MAGAZINE STORAGE BUILDING (BUILDING 3572). VIEW TO NORTHWEST - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY
NASA Astrophysics Data System (ADS)
Kar, Rony; Dalui, Sujit Kumar
2016-03-01
The variation of pressure at the faces of the octagonal plan shaped tall building due to interference of three square plan shaped tall building of same height is analysed by computational fluid dynamics module, namely ANSYS CFX for 0° wind incidence angle only. All the buildings are closely spaced (distance between two buildings varies from 0.4 h to 2 h, where h is the height of the building). Different cases depending upon the various positions of the square plan shaped buildings are analysed and compared with the octagonal plan shaped building in isolated condition. The comparison is presented in the form of interference factors (IF) and IF contours. Abnormal pressure distribution is observed in some cases. Shielding and channelling effect on the octagonal plan shaped building due to the presence of the interfering buildings are also noted. In the interfering condition the pressure distribution at the faces of the octagonal plan shaped building is not predictable. As the distance between the principal octagonal plan shaped building and the third square plan shaped interfering building increases the behaviour of faces becomes more systematic. The coefficient of pressure (C p) for each face of the octagonal plan shaped building in each interfering case can be easily found if we multiply the IF with the C p in the isolated case.
Green Building Tools for Tribes
Tribal green building tools and funding information to support tribal building code adoption, healthy building, siting, energy efficiency, renewable energy, water conservation, green building materials, recycling and adaptation and resilience.
Building damage assessment from PolSAR data using texture parameters of statistical model
NASA Astrophysics Data System (ADS)
Li, Linlin; Liu, Xiuguo; Chen, Qihao; Yang, Shuai
2018-04-01
Accurate building damage assessment is essential in providing decision support for disaster relief and reconstruction. Polarimetric synthetic aperture radar (PolSAR) has become one of the most effective means of building damage assessment, due to its all-day/all-weather ability and richer backscatter information of targets. However, intact buildings that are not parallel to the SAR flight pass (termed oriented buildings) and collapsed buildings share similar scattering mechanisms, both of which are dominated by volume scattering. This characteristic always leads to misjudgments between assessments of collapsed buildings and oriented buildings from PolSAR data. Because the collapsed buildings and the intact buildings (whether oriented or parallel buildings) have different textures, a novel building damage assessment method is proposed in this study to address this problem by introducing texture parameters of statistical models. First, the logarithms of the estimated texture parameters of different statistical models are taken as a new texture feature to describe the collapse of the buildings. Second, the collapsed buildings and intact buildings are distinguished using an appropriate threshold. Then, the building blocks are classified into three levels based on the building block collapse rate. Moreover, this paper also discusses the capability for performing damage assessment using texture parameters from different statistical models or using different estimators. The RADARSAT-2 and ALOS-1 PolSAR images are used to present and analyze the performance of the proposed method. The results show that using the texture parameters avoids the problem of confusing collapsed and oriented buildings and improves the assessment accuracy. The results assessed by using the K/G0 distribution texture parameters estimated based on the second moment obtain the highest extraction accuracies. For the RADARSAT-2 and ALOS-1 data, the overall accuracy (OA) for these three types of buildings is 73.39% and 68.45%, respectively.
Fitzsimons General Hospital, Physiotherapy & Electrocardiograph Department Building, North of ...
Fitzsimons General Hospital, Physiotherapy & Electrocardiograph Department Building, North of Building No. 516, East of corridor connecting Building No. 511 to Building No. 515, Aurora, Adams County, CO
1. VIEW LOOKING NORTHWEST AT BUILDING 701. BUILDING 701 WAS ...
1. VIEW LOOKING NORTHWEST AT BUILDING 701. BUILDING 701 WAS USED TO DESIGN, BUILD, AND EVALUATE BENCH-SCALE TECHNOLOGIES USED IN ROCKY FLATS WASTE TREATMENT PROCESSES. (1/98) - Rocky Flats Plant, Design Laboratory, Northwest quadrant of Plant, between buildings 776-777 & 771, Golden, Jefferson County, CO
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-24
... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... agenda for the May 9, 2012, meeting of the Green Building Advisory Committee Meeting (the Committee). The... Sandler, Designated Federal Officer, Office of Federal High-Performance Green Buildings, Office of...
The Teaching Green School Building: A Framework for Linking Architecture and Environmental Education
ERIC Educational Resources Information Center
Cole, Laura B.
2014-01-01
The "Teaching Green School Building" is an emergent type of school building that attempts to engage building users with environmental issues in buildings. Architectural interventions in these buildings range from signage to interactive touch screens to gardens and demonstration kitchens that foster educational programmes about…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-06
... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... and agenda for the November 27, 2012, meeting of the Green Building Advisory Committee Meeting (the... Green Buildings, Office of Government-wide Policy, General Services Administration, 1275 First Street NE...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-20
... Federal High-Performance Green Buildings; Establishment of the Green Building Advisory Committee AGENCY... announces the establishment of the Green Building Advisory Committee (the Committee), pursuant to Section... strategic plans, products and activities of the Office of Federal High-Performance Green Buildings and...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-10
... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... and agenda for the May 1, 2013, meeting of the Green Building Advisory Committee Meeting (the... Green Buildings, Office of Government-wide Policy, General Services Administration, 1275 First Street NE...
Building C west elevation showing south elevation of Building B ...
Building C west elevation showing south elevation of Building B (on left) and north elevation of Building D (on right). The Germantown Dyeworks complex and smoke stack appear in the background. View looking east - Hinckley Knitting Mills, Building C, 21-35 East Wister Street, Philadelphia, Philadelphia County, PA
An image, looking southeast down the passage between E Building ...
An image, looking southeast down the passage between E Building and M Building immediately to the east. The east entrance and the south wing of the building are visible - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH
24. AERIAL VIEW LOOKING SOUTHEAST AT BUILDING 371 UNDER CONSTRUCTION ...
24. AERIAL VIEW LOOKING SOUTHEAST AT BUILDING 371 UNDER CONSTRUCTION IN 1974. BY 1968, BUILDING 771 WAS OUTMODED AND NEW TECHNOLOGIES HAD BEEN DEVELOPED FOR PLUTONIUM RECOVERY. AS A RESULT, A NEW RECOVERY BUILDING, BUILDING 371 WAS PLANNED. BUILDING 371 SUFFERED FROM VARIOUS DESIGN PROBLEMS, WHICH PREVENTED ITS OPENING UNTIL 1981 AND CAUSED TERMINATION OF RECOVERY OPERATIONS IN 1986. IT NEVER BECAME FULLY OPERATIONAL. TO THE EAST OF BUILDING 371, IS THE 700 BUILDING COMPLEX (4/74). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
NASA Technical Reports Server (NTRS)
Hirshberg, A. S.
1975-01-01
The following topics are discussed: (1) Assignment of population to microclimatic zones; (2) specifications of the mix of buildings in the SCE territory; (3) specification of four typical buildings for thermal analysis and market penetration studies; (4) identification of the materials and energy conserving characteristics of these typical buildings; (5) specifications of the HVAC functions used in each typical building, and determination of the HVAC systems used in each building; and (6) identification of the type of fuel used in each building.
The impact of green building approach to office property value
NASA Astrophysics Data System (ADS)
Sitanggang, Yosephine; Susanto, Dalhar
2017-12-01
A real estate development often produces negative impacts towards the environment such as the reduction of the ecological capacity in the site and its surroundings, energy exploitation, and excessive pollutant emission. To overcome these issues, the green building concept or approach has been adapted by several real estate businesses in Indonesia especially in the office sector. According to the data provided by GBCI in 2017, there are 17 buildings listed as a certified green building office in various levels. As what has been known, the green building approach results in the increase of price in the planning, construction and the building's maintenance. This paper will discuss about the research results regarding the effect of the green building approach towards the property value of office buildings especially in Jakarta. The research will be executed through the comparison method, which is the process of comparing office building that have already adapted the green building concept with the one that have not, or in other words, the conventional office buildings. Data gathering is done through observation and interviews with developers and building managers. The research results show that by adapting the green building approach for office buildings in Jakarta, the property value regarding the utility, scarcity, effective demands, and transferability aspect can increase.
11. SITE BUILDING 002 SCANNER BUILDING EVAPORATIVE COOLING ...
11. SITE BUILDING 002 - SCANNER BUILDING - EVAPORATIVE COOLING TOWER SYSTEM IN FOREGROUND. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Review of Methods for Buildings Energy Performance Modelling
NASA Astrophysics Data System (ADS)
Krstić, Hrvoje; Teni, Mihaela
2017-10-01
Research presented in this paper gives a brief review of methods used for buildings energy performance modelling. This paper gives also a comprehensive review of the advantages and disadvantages of available methods as well as the input parameters used for modelling buildings energy performance. European Directive EPBD obliges the implementation of energy certification procedure which gives an insight on buildings energy performance via exiting energy certificate databases. Some of the methods for buildings energy performance modelling mentioned in this paper are developed by employing data sets of buildings which have already undergone an energy certification procedure. Such database is used in this paper where the majority of buildings in the database have already gone under some form of partial retrofitting - replacement of windows or installation of thermal insulation but still have poor energy performance. The case study presented in this paper utilizes energy certificates database obtained from residential units in Croatia (over 400 buildings) in order to determine the dependence between buildings energy performance and variables from database by using statistical dependencies tests. Building energy performance in database is presented with building energy efficiency rate (from A+ to G) which is based on specific annual energy needs for heating for referential climatic data [kWh/(m2a)]. Independent variables in database are surfaces and volume of the conditioned part of the building, building shape factor, energy used for heating, CO2 emission, building age and year of reconstruction. Research results presented in this paper give an insight in possibilities of methods used for buildings energy performance modelling. Further on it gives an analysis of dependencies between buildings energy performance as a dependent variable and independent variables from the database. Presented results could be used for development of new building energy performance predictive model.
Analysis of the Seismic Performance of Isolated Buildings according to Life-Cycle Cost
Dang, Yu; Han, Jian-ping; Li, Yong-tao
2015-01-01
This paper proposes an indicator of seismic performance based on life-cycle cost of a building. It is expressed as a ratio of lifetime damage loss to life-cycle cost and determines the seismic performance of isolated buildings. Major factors are considered, including uncertainty in hazard demand and structural capacity, initial costs, and expected loss during earthquakes. Thus, a high indicator value indicates poor building seismic performance. Moreover, random vibration analysis is conducted to measure structural reliability and evaluate the expected loss and life-cycle cost of isolated buildings. The expected loss of an actual, seven-story isolated hospital building is only 37% of that of a fixed-base building. Furthermore, the indicator of the structural seismic performance of the isolated building is much lower in value than that of the structural seismic performance of the fixed-base building. Therefore, isolated buildings are safer and less risky than fixed-base buildings. The indicator based on life-cycle cost assists owners and engineers in making investment decisions in consideration of structural design, construction, and expected loss. It also helps optimize the balance between building reliability and building investment. PMID:25653677
Analysis of the seismic performance of isolated buildings according to life-cycle cost.
Dang, Yu; Han, Jian-Ping; Li, Yong-Tao
2015-01-01
This paper proposes an indicator of seismic performance based on life-cycle cost of a building. It is expressed as a ratio of lifetime damage loss to life-cycle cost and determines the seismic performance of isolated buildings. Major factors are considered, including uncertainty in hazard demand and structural capacity, initial costs, and expected loss during earthquakes. Thus, a high indicator value indicates poor building seismic performance. Moreover, random vibration analysis is conducted to measure structural reliability and evaluate the expected loss and life-cycle cost of isolated buildings. The expected loss of an actual, seven-story isolated hospital building is only 37% of that of a fixed-base building. Furthermore, the indicator of the structural seismic performance of the isolated building is much lower in value than that of the structural seismic performance of the fixed-base building. Therefore, isolated buildings are safer and less risky than fixed-base buildings. The indicator based on life-cycle cost assists owners and engineers in making investment decisions in consideration of structural design, construction, and expected loss. It also helps optimize the balance between building reliability and building investment.
Typological diversity of tall buildings and complexes in relation to their functional structure
NASA Astrophysics Data System (ADS)
Generalov, Viktor P.; Generalova, Elena M.; Kalinkina, Nadezhda A.; Zhdanova, Irina V.
2018-03-01
The paper focuses on peculiarities of tall buildings and complexes, their typology and its formation in relation to their functional structure. The research is based on the analysis of tall buildings and complexes and identifies the following main functional elements of their formation: residential, administrative (office), hotel elements. The paper also considers the following services as «disseminated» in the space-planning structure: shops, medicine, entertainment, kids and sports facilities, etc., their location in the structure of the total bulk of the building and their impact on typological diversity. Research results include suggestions to add such concepts as «single-function tall buildings» and «mixed-use tall buildings and complexes» into the classification of tall buildings. In addition, if a single-function building or complex performs serving functions, it is proposed to add such concepts as «a residential tall building (complex) with provision of services», «an administrative (public) tall building (complex) with provision of services» into the classification of tall buildings. For mixed-use buildings and complexes the following terms are suggested: «a mixed-use tall building with provision of services», «a mixed-use tall complex with provision of services».
Object Based Building Extraction and Building Period Estimation from Unmanned Aerial Vehicle Data
NASA Astrophysics Data System (ADS)
Comert, Resul; Kaplan, Onur
2018-04-01
The aim of this study is to examine whether it is possible to estimate the building periods with respect to the building heights in the urban scale seismic performance assessment studies by using the building height retrieved from the unmanned aerial vehicle (UAV) data. For this purpose, a small area, which includes eight residential reinforced concrete buildings, was selected in Eskisehir (Turkey) city center. In this paper, the possibilities of obtaining the building heights that are used in the estimation of building periods from UAV based data, have been investigated. The investigations were carried out in 3 stages; (i) Building boundary extraction with Object Based Image Analysis (OBIA), (ii) height calculation for buildings of interest from nDSM and accuracy assessment with the terrestrial survey. (iii) Estimation of building period using height information. The average difference between the periods estimated according to the heights obtained from field measurements and from the UAV data is 2.86 % and the maximum difference is 13.2 %. Results of this study have shown that the building heights retrieved from the UAV data can be used in the building period estimation in the urban scale vulnerability assessments.
23. AERIAL VIEW LOOKING SOUTHEAST AT THE PLUTONIUM OPERATION BUILDINGS ...
23. AERIAL VIEW LOOKING SOUTHEAST AT THE PLUTONIUM OPERATION BUILDINGS 771, 776/777, AND 707. BUILDING 771, IN THE FOREGROUND, WAS BUILT IN 1952 TO HOUSE ALL PLUTONIUM OPERATIONS. BY 1956, BUILDING 771 WAS NO LONGER ADEQUATE FOR PRODUCTION DEMANDS. BUILDING 776/777, TO THE SOUTH OF BUILDING 771, WAS CONSTRUCTED TO HOUSE PLUTONIUM FABRICATION AND FOUNDRY OPERATIONS. PLUTONIUM RECOVERY REMAINED IN BUILDING 771. BY 1967, CONSTRUCTION ON BUILDING 707, TO THE SOUTH OF BUILDING 776/777, BEGAN AS PRODUCTION LEVELS CONTINUED TO EXPAND NECESSITATING THE NEED FOR ADDITIONAL PLUTONIUM FABRICATION SPACE (7/1/69). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
1. John C. Garner, Jr., Photographer 1967 PRINCIPAL (NORTH) SIDE, ...
1. John C. Garner, Jr., Photographer 1967 PRINCIPAL (NORTH) SIDE, FROM NORTHWEST. THE RIGHT END OF THE BLOCK IS THE E.S. WOOD BUILDING; THE BUILDING WITH A FIRE ESCAPE IS THE ROSENFIELD BUILDING; THE T.W. HOUSE BUILDING IS TO THE LEFT OF THE PRECEDING BUILDING; JOHN BERLOCHER BUILDING IS AT THE LEFT END OF THE BLOCK. - Strand Historic District, Wood-Rosenfield-House-Berlocher Buildings, 2213-2223 Strand, Galveston, Galveston County, TX
Black Maria Reconstruction (left foreground); Building No. 1; Main Building; ...
Black Maria Reconstruction (left foreground); Building No. 1; Main Building; Edison Storage Battery Building (right background) - Thomas A. Edison Laboratories, Main Street & Lakeside Avenue, West Orange, Essex County, NJ
EXTERIOR VIEW, THE SA WETSIDE BUILDING (ALSO KNOWN AS DISTILLATION ...
EXTERIOR VIEW, THE SA WETSIDE BUILDING (ALSO KNOWN AS DISTILLATION BUILDING OR SOLVAY TOWERS BUILDING) THE HEART OF THE SOLVAY PROCESS. VIEW LOOKING EAST. THIS BUILDING WAS BUILT IN 1954 TO REPLACE A SIMILAR STRUCTURE BUILT CIRCA 1907. - Solvay Process Company, SA Wetside Building, Between Willis & Milton Avenue, Solvay, Onondaga County, NY
31. SOUTH PLANT NORTHERN EDGE, SHOWING CELL BUILDING (BUILDING 242) ...
31. SOUTH PLANT NORTHERN EDGE, SHOWING CELL BUILDING (BUILDING 242) AT LEFT, LABORATORY (BUILDING 241) AT CENTER AND CAUSTIC FUSION PLANT (BUILDING 254) AT RIGHT. VIEW TO SOUTHWEST. - Rocky Mountain Arsenal, Bounded by Ninety-sixth Avenue & Fifty-sixth Avenue, Buckley Road, Quebec Street & Colorado Highway 2, Commerce City, Adams County, CO
Context view, Building Nos. 2729, with Building No. 28 in ...
Context view, Building Nos. 27-29, with Building No. 28 in the center, looking west at front of buildings, from a spot south of Building No. 29 - U.S. Veterans Hospital, Jefferson Barracks, Medical Officer in Charge Residence, VA Medical Center, Jefferson Barracks Division 1 Jefferson Barracks Drive, Saint Louis, Independent City, MO
51. CONTEXT VIEW LOOKING NORTHWEST OF BUILDING 365 (ARMAMENT TESTING ...
51. CONTEXT VIEW LOOKING NORTHWEST OF BUILDING 365 (ARMAMENT TESTING BUILDING) IN BASE SPARES AREA WITH BUILDING 367 (ADMINISTRATIVE OFFICE BUILDING) IN MIDDLE GROUND AND BUILDING 368 (WAREHOUSE) IN BACKGROUND. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
1. Distant view shows Engine Room Building behind cranes. Retort ...
1. Distant view shows Engine Room Building behind cranes. Retort rings in foreground were once located in Engine Room Building. See photo WA-131-A-2. Building on left is Machine Shop. Boiler Building is in front of stack. - Pacific Creosoting Plant, Engine Room Building, 5350 Creosote Place, Northeast, Bremerton, Kitsap County, WA
1. VIEW LOOKING SOUTH AT BUILDING 771 UNDER CONSTRUCTION. BUILDING ...
1. VIEW LOOKING SOUTH AT BUILDING 771 UNDER CONSTRUCTION. BUILDING 771 WAS ONE OF THE FIRST FOUR MAJOR BUILDINGS AT THE ROCKY FLATS PLANT, BUILDING 771 WAS ORIGINALLY THE PRIMARY FACILITY FOR PLUTONIUM OPERATIONS. (5/29/52) - Rocky Flats Plant, Plutonium Recovery & Fabrication Facility, North-central section of plant, Golden, Jefferson County, CO
FAST CHOPPER BUILDING, TRA665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. ...
FAST CHOPPER BUILDING, TRA-665. CONTEXTUAL VIEW: CHOPPER BUILDING IN CENTER. MTR REACTOR SERVICES BUILDING,TRA-635, TO LEFT; MTR BUILDING TO RIGHT. CAMERA FACING WEST. INL NEGATIVE NO. HD42-1. Mike Crane, Photographer, 3/2004 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
13. A southeastward view of buildings #3 (on the right), ...
13. A southeastward view of buildings #3 (on the right), building #5 ( to the immediate left of building #3), and buildings #6-B (low building on the far left) and #6 ( to the immediate rear of #6-B). - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA
Comparative study of air-conditioning energy use of four office buildings in China and USA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Xin; Yan, Da; An, Jingjing
Energy use in buildings has great variability. In order to design and operate low energy buildings as well as to establish building energy codes and standards and effective energy policy, it is crucial to understand and quantify key factors influencing building energy performance. Here, this study investigates air-conditioning (AC) energy use of four office buildings in four locations: Beijing, Taiwan, Hong Kong, and Berkeley. Building simulation was employed to quantify the influences of key factors, including climate, building envelope and occupant behavior. Through simulation of various combinations of the three influencing elements, it is found that climate can lead tomore » AC cooling consumption differences by almost two times, while occupant behavior resulted in the greatest differences (of up to three times) in AC cooling consumption. The influence of occupant behavior on AC energy consumption is not homogeneous. Under similar climates, when the occupant behavior in the building differed, the optimized building envelope design also differed. In conclusion, the optimal building envelope should be determined according to the climate as well as the occupants who use the building.« less
Comparative study of air-conditioning energy use of four office buildings in China and USA
Zhou, Xin; Yan, Da; An, Jingjing; ...
2018-04-05
Energy use in buildings has great variability. In order to design and operate low energy buildings as well as to establish building energy codes and standards and effective energy policy, it is crucial to understand and quantify key factors influencing building energy performance. Here, this study investigates air-conditioning (AC) energy use of four office buildings in four locations: Beijing, Taiwan, Hong Kong, and Berkeley. Building simulation was employed to quantify the influences of key factors, including climate, building envelope and occupant behavior. Through simulation of various combinations of the three influencing elements, it is found that climate can lead tomore » AC cooling consumption differences by almost two times, while occupant behavior resulted in the greatest differences (of up to three times) in AC cooling consumption. The influence of occupant behavior on AC energy consumption is not homogeneous. Under similar climates, when the occupant behavior in the building differed, the optimized building envelope design also differed. In conclusion, the optimal building envelope should be determined according to the climate as well as the occupants who use the building.« less
Performance or marketing benefits? The case of LEED certification.
Matisoff, Daniel C; Noonan, Douglas S; Mazzolini, Anna M
2014-01-01
Green building adoption is driven by both performance-based benefits and marketing based benefits. Performance based benefits are those that improve performance or lower operating costs of the building or of building users. Marketing benefits stem from the consumer response to green certification. This study illustrates the relative importance of the marketing based benefits that accrue to Leadership in Energy and Environmental Design (LEED) buildings due to green signaling mechanisms, specifically related to the certification itself are identified. Of course, all participants in the LEED certification scheme seek marketing benefits. But even among LEED participants, the interest in green signaling is pronounced. The green signaling mechanism that occurs at the certification thresholds shifts building patterns from just below to just above the threshold level, and motivates builders to cluster buildings just above each threshold. Results are consistent across subsamples, though nonprofit organizations appear to build greener buildings and engage in more green signaling than for-profit entities. Using nonparametric regression discontinuity, signaling across different building types is observed. Marketing benefits due to LEED certification drives organizations to build "greener" buildings by upgrading buildings at the thresholds to reach certification levels.
Allen, Joseph G; MacNaughton, Piers; Laurent, Jose Guillermo Cedeno; Flanigan, Skye S; Eitland, Erika Sita; Spengler, John D
2015-09-01
Green building design is becoming broadly adopted, with one green building standard reporting over 3.5 billion square feet certified to date. By definition, green buildings focus on minimizing impacts to the environment through reductions in energy usage, water usage, and minimizing environmental disturbances from the building site. Also by definition, but perhaps less widely recognized, green buildings aim to improve human health through design of healthy indoor environments. The benefits related to reduced energy and water consumption are well-documented, but the potential human health benefits of green buildings are only recently being investigated. The objective of our review was to examine the state of evidence on green building design as it specifically relates to indoor environmental quality and human health. Overall, the initial scientific evidence indicates better indoor environmental quality in green buildings versus non-green buildings, with direct benefits to human health for occupants of those buildings. A limitation of much of the research to date is the reliance on indirect, lagging and subjective measures of health. To address this, we propose a framework for identifying direct, objective and leading "Health Performance Indicators" for use in future studies of buildings and health.
Building thermography as a tool in energy audits and building commissioning procedure
NASA Astrophysics Data System (ADS)
Kauppinen, Timo
2007-04-01
A Building Commissioning-project (ToVa) was launched in Finland in the year 2003. A comprehensive commissioning procedure, including the building process and operation stage was developed in the project. This procedure will confirm the precise documentation of client's goals, definition of planning goals and the performance of the building. It is rather usual, that within 1-2 years after introduction the users complain about the defects or performance malfunctions of the building. Thermography is one important manual tool in verifying the thermal performance of the building envelope. In this paper the results of one pilot building (a school) will be presented. In surveying the condition and energy efficiency of buildings, various auxiliary means are needed. We can compare the consumption data of the target building with other, same type of buildings by benchmarking. Energy audit helps to localize and determine the energy saving potential. The most general and also most effective auxiliary means in monitoring the thermal performance of building envelopes is an infrared camera. In this presentation some examples of the use of thermography in energy audits are presented.
28. Ventilation Building located on front lawn of building 500, ...
28. Ventilation Building located on front lawn of building 500, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE
58. Corridor, building 500 to building 515, basement level, looking ...
58. Corridor, building 500 to building 515, basement level, looking southeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE
29. Ventilation Building located on front lawn of building 500, ...
29. Ventilation Building located on front lawn of building 500, looking northeast - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE
33. SITE BUILDING 002 SCANNER BUILDING MECHANICAL ROOM ...
33. SITE BUILDING 002 - SCANNER BUILDING - MECHANICAL ROOM 105, VIEW OF CHILLER ROOM MOTOR CONTROL CENTER. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Use Of Infrared Thermography For The Identification Of Design And Construction Faults In Buildings
NASA Astrophysics Data System (ADS)
Seeber, Stephen A.
1984-03-01
Many design and construction details can affect building energy consumption in unex-pected ways. Further, design and construction errors can increase building energy consumption, result in discomfort to building occupants and cause structural damage to the building. Infrared inspections can easily evaluate the energy efficiency of various aspects of a building's design and identify flaws that might otherwise be detected as a result of occupants' complaints or damage to the building's mechanical or structural systems. Infrared thermography can be used by the architect to evaluate his designs and by the contractor to control the quality of construction. This paper discusses a number of issues that can help determine the effectiveness of infrared building surveys. Following this, three case stud-ies will be presented to illustrate design flaws that were detected through infrared build-ing surveys.
Leveraging organizational dynamics in buildings to change behavior
NASA Astrophysics Data System (ADS)
Hewitt, Elizabeth L.
Buildings may be stationary, but they are not static; they are dynamic and active collectives of agents and actors, and play an important cultural and social role in shaping norms and influencing outcomes in the built environment. This research develops and applies a unique framework that conceptualizes the urban multifamily residential building as an organization, and seeks to use this lens to better understand the role of organizational characteristics in influencing energy efficiency in buildings. This work finds that an organizational analogy is a fruitful approach for understanding buildings, and that buildings in many ways can and do function successfully as organizations. In particular, eight organizational characteristics are explored here that extend well to buildings. These eight organizational characteristics are also explored more deeply to support an argument that some buildings have an organizational advantage that well positions them to undertake energy efficiency initiatives. One organizational characteristic -- the ownership type of the building -- is determined to be particularly important in driving energy outcomes in multifamily buildings in New York City. In particular, it was found that cooperative buildings in the New York City housing market consume less energy citywide than other types of multifamily properties, holding all else equal. Conversely, it was also found that rental buildings tend to consume more energy citywide. Subsequent qualitative case study work in a small Brooklyn cooperative building offers a deeper understanding of organizational decentralization and its role in driving decision-making and outcomes in the building. Additional comparative work in two rental properties -- one high-income and one low-income -- adds additional context and understanding to economic considerations such as the influence of income in overriding centralized efforts to operate the building efficiently. Ultimately, this research develops an analogy of buildings-as-organizations -- a conceptual framework -- to better understand tangible built space. It posits that all buildings can function as organizations, and extends this framework to the urban multifamily building to advance knowledge of energy efficiency.
NASA Astrophysics Data System (ADS)
Takano, K.; Ito, T.
2010-12-01
There are a lot of buildings which is not experienced severe earthquakes in urban area. In Hanshin-Awaji (Kobe) Earthquake, it was presumed that 80 percent or more of the person was dead immediately after the earthquake by building collapse. Also in Haiti, a lot of buildings deprived of the life of persons. In order to prevent the earthquake damage of urban area, it is the most effective to make the building earthquake-proof. However, there are still a lot of buildings not made earthquake-proof in Japan though 15 years passed since Kobe Earthquake. In order to promote making of the building earthquake-proof, various approaches such as visualization of seismic hazard, education of disaster prevention and legal system for promotion are needed. We have developed the IT Kyoshin(strong motion) Seismometer for Building which is the observation system of the usual weak earthquake ground motion by installing a lot of acceleration sensors in building, and have been setting it up in some buildings of the University of Tokyo. We have also developed the visualization tool that can reproduce the building vibration during earthquake from the observed data. By this tool, we can successfully show where is more shaking in the building or what is the feature of building vibration easily. Such information contributes to not only promotion of making building earthquake-proof but also promotion of disaster prevention action such as fixation of bookshelf, making the safety area in building, etc. In addition, we proposed a concrete technique of the health investigation of buildings by using weak earthquake ground motion. Because there are 20 to 30 felt earthquakes in year in Tokyo area, it is possible to observe these building vibrations by using weak earthquake ground motions. In addition, we have developed the high sensitive ITK sensor which can observe from the microtremor to the felt earthquake in the place without the felt earthquake either.
Hall, Zachary J; Meddle, Simone L; Healy, Susan D
Despite centuries of observing the nest building of most extant bird species, we know surprisingly little about how birds build nests and, specifically, how the avian brain controls nest building. Here, we argue that nest building in birds may be a useful model behaviour in which to study how the brain controls behaviour. Specifically, we argue that nest building as a behavioural model provides a unique opportunity to study not only the mechanisms through which the brain controls behaviour within individuals of a single species but also how evolution may have shaped the brain to produce interspecific variation in nest-building behaviour. In this review, we outline the questions in both behavioural and comparative neuroscience that nest building could be used to address, summarize recent findings regarding the neurobiology of nest building in lab-reared zebra finches and across species building different nest structures, and suggest some future directions for the neurobiology of nest building.
Commercial Building Energy Asset Score Program Overview and Technical Protocol (Version 1.1)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Goel, Supriya; Makhmalbaf, Atefe
The U.S. Department of Energy (DOE) is developing a voluntary national scoring system for commercial buildings to help building owners and managers assess a building’s energy-related systems independent of operations. The goal of the score is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system, known as the Commercial Building Energy Asset Score, will allow building owners and managers to compare their building infrastructure against peers and track building upgrades over time. The system will also help other building stakeholders (e.g., building investors, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in amore » way that is independent from operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset scoring tool. The alternative methods that were considered prior to developing the current approach are described in the Program Overview and Technical Protocol Version 1.0.« less
Commercial Building Energy Asset Score
DOE Office of Scientific and Technical Information (OSTI.GOV)
This software (Asset Scoring Tool) is designed to help building owners and managers to gain insight into the as-built efficiency of their buildings. It is a web tool where users can enter their building information and obtain an asset score report. The asset score report consists of modeled building energy use (by end use and by fuel type), building systems (envelope, lighting, heating, cooling, service hot water) evaluations, and recommended energy efficiency measures. The intended users are building owners and operators who have limited knowledge of building energy efficiency. The scoring tool collects minimum building data (~20 data entries) frommore » users and build a full-scale energy model using the inference functionalities from Facility Energy Decision System (FEDS). The scoring tool runs real-time building energy simulation using EnergyPlus and performs life-cycle cost analysis using FEDS. An API is also under development to allow the third-party applications to exchange data with the web service of the scoring tool.« less
Surveying for architectural students: as simple as possible - as much as necessary
NASA Astrophysics Data System (ADS)
Mayer, I.; Mitterecker, T.
2017-08-01
More and more, existing buildings - and particularly historic buildings - are becoming part of the daily business of every architect. Planning and designing in the field of architectural heritage requires not only knowledge of contemporary building techniques, design processes and national and international guidelines, but also a deep understanding of architectural heritage, its evolution and genesis, the building techniques that have been applied, materials used, traditions, etc. In many cases, it is indispensable to perform a detailed building survey and building research to achieve an adequate design concept. The Department of History of Architecture and Building Archaeology of TU Wien has an extensive tradition of building research and over the course of the past 10 years, has developed a teaching workflow to introduce architectural students to building archaeology und surveying methods for building research. A sophisticated, temporally interwoven combination of courses and lectures on different topics related to building archaeology and surveying rapidly gives the architectural students the right tools for this important but often neglected task.
Solar energy in buildings solved by building information modeling
NASA Astrophysics Data System (ADS)
Chudikova, B.; Faltejsek, M.
2018-03-01
Building lead us to use renewable energy sources for all types of buildings. The use of solar energy is the alternatives that can be applied in a good ratio of space, price, and resultant benefits. Building Information Modelling is a modern and effective way of dealing with buildings with regard to all aspects of the life cycle. The basis is careful planning and simulation in the pre-investment phase, where it is possible to determine the effective result and influence the lifetime of the building and the cost of its operation. By simulating, analysing and insert a building model into its future environment where climate conditions and surrounding buildings play a role, it is possible to predict the usability of the solar energy and establish an ideal model. Solar systems also very affect the internal layout of buildings. Pre-investment phase analysis, with a view to future aspects, will ensure that the resulting building will be both low-energy and environmentally friendly.
ETR BUILDING, TRA642. SOUTH SIDE VIEW INCLUDES SOUTH SIDES OF ...
ETR BUILDING, TRA-642. SOUTH SIDE VIEW INCLUDES SOUTH SIDES OF ETR BUILDING (HIGH ROOF LINE); ELECTRICAL BUILDING (ONE-STORY, MADE OF PUMICE BLOCKS), TRA-648; AND HEAT EXCHANGER BUILDING (WITH BUILDING NUMBERS), TRA-644. NOTE PROJECTION OF ELECTRICAL BUILDING AT LEFT EDGE OF VIEW. CAMERA FACES NORTH. INL NEGATIVE NO. HD46-37-3. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Patton, Allison P.; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J.; Krogmann, Uta; Mainelis, Gediminas
2016-01-01
There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m3) than in Building L (37 µg/m3); I/O was higher in Building E (1.3–2.0) than in Building L (0.5–0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents’ exposure to PM in residential green buildings. PMID:26805862
Patton, Allison P; Calderon, Leonardo; Xiong, Youyou; Wang, Zuocheng; Senick, Jennifer; Sorensen Allacci, MaryAnn; Plotnik, Deborah; Wener, Richard; Andrews, Clinton J; Krogmann, Uta; Mainelis, Gediminas
2016-01-20
There are limited data on air quality parameters, including airborne particulate matter (PM) in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1) measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E) and mechanical (Building L) ventilation; (2) compare indoor and outdoor PM mass concentrations and their ratios (I/O) in these buildings, taking into account the effects of occupant behavior; and (3) evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m³) than in Building L (37 µg/m³); I/O was higher in Building E (1.3-2.0) than in Building L (0.5-0.8) for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation) are important factors affecting residents' exposure to PM in residential green buildings.
Building Energy Consumption Pattern Analysis of Detached Housing for the Policy Decision Simulator
NASA Astrophysics Data System (ADS)
Lim, Jiyoun; Lee, Seung-Eon
2018-03-01
The Korean government announced its plan to raise the previous reduction goal of greenhouse gas emission from buildings by 26.9% until 2020 on July 2015. Therefore, policies regarding efficiency in the building energy are implemented fast, but the level of building owners and market understanding is low in general, and the government service system which supports decision making for implementing low-energy buildings has not been provided yet. The purpose of this study is to present the design direction for establishing user customized building energy database to perform a role to provide autonomous ecosystem of low-energy buildings. In order to reduce energy consumption in buildings, it is necessary to carry out the energy performance analysis based on the characteristics of target building. By analysing about 20-thousand cases of the amount of housing energy consumption in Korea, this study suggested the real energy consumption pattern by building types. Also, the energy performance of a building could be determined by energy consumption, but previous building energy consumption analysis programs required expert knowledge and experience in program usage, so it was difficult for normal building users to use such programs. Therefore, a measure to provide proper default using the level of data which general users with no expert knowledge regarding building energy could enter easily was suggested in this study.
Maximize Energy Efficiency in Buildings | Climate Neutral Research Campuses
Buildings on a research campus, especially laboratory buildings, often represent the most cost-effective plans, campuses can evaluate the following: Energy Management Building Management New Buildings Design
5. ROOFTOPS, ISHERWOOD HALL (BUILDING NO. 104), GRIFFIN (BUILDING NO. ...
5. ROOFTOPS, ISHERWOOD HALL (BUILDING NO. 104), GRIFFIN (BUILDING NO. 110), MELVILLE HALL (BUILDING NO. 116) LOOKING WEST FROM CLOCK TOWER OF MAHAN HALL - U.S. Naval Academy, Annapolis, Anne Arundel County, MD
18. SITE BUILDING 002 SCANNER BUILDING VIEW OF ...
18. SITE BUILDING 002 - SCANNER BUILDING - VIEW OF SITE SECURITY OFFICE ACCESS DOOR FROM EXTERIOR OF OFFICE. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
24. SITE BUILDING 002 SCANNER BUILDING OPERATIONS CENTER ...
24. SITE BUILDING 002 - SCANNER BUILDING - OPERATIONS CENTER -- MWOC IN OPEARATION AT 1924 ZULU TIME. 26 OCTOBER, 1999. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
57. BUILDING NO. 1071, ORDNANCE FACILITY (CRYSTALLIZATION BUILDING), LOOKING AT ...
57. BUILDING NO. 1071, ORDNANCE FACILITY (CRYSTALLIZATION BUILDING), LOOKING AT SOUTHEAST SIDE. NOTE ESCAPE CHUTES PROJECTING FROM SIDES OF BUILDING. - Picatinny Arsenal, State Route 15 near I-80, Dover, Morris County, NJ
4. VIEW OF SECURITY GATE LOOKING SOUTHWEST FROM ROOF OF ...
4. VIEW OF SECURITY GATE LOOKING SOUTHWEST FROM ROOF OF BUILDING 8970 (CREW READINESS BUILDING) SHOWING BUILDING 8965 (SECURITY POLICE ENTRY CONTROL BUILDING) IN RIGHT MIDDLE GROUND AND BUILDING 8966 (ELECTRIC POWER STATION BUILDING) IN RIGHT FOREGROUND. - Loring Air Force Base, Alert Area, Southeastern portion of base, east of southern end of runway, Limestone, Aroostook County, ME
62. BUILDING NO. 1301, ORDNANCE FACILITY (MORTAR POWDER BUILDING), LOOKING ...
62. BUILDING NO. 1301, ORDNANCE FACILITY (MORTAR POWDER BUILDING), LOOKING AT NORTHWEST FACADE. ACCESS TO ROOF ALLOWS MAINTENANCE OF VENTILATION EQUIPMENT WHICH IS PLACED OUTSIDE BUILDING TO MINIMIZE EXPLOSION HAZARD. NO. 2 VISIBLE ON WALL OF BUILDING STANDS FOR EXPLOSION HAZARD WITH FRAGMENTATION. - Picatinny Arsenal, State Route 15 near I-80, Dover, Morris County, NJ
Commercial Building Tenant Energy Usage Aggregation and Privacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Livingston, Olga V.; Pulsipher, Trenton C.; Anderson, David M.
A growing number of building owners are benchmarking their building energy use. This requires the building owner to acquire monthly whole-building energy usage information, which can be challenging for buildings in which individual tenants have their own utility meters and accounts with the utility. Some utilities and utility regulators have turned to aggregation of customer energy use data (CEUD) as a way to give building owners whole-building energy usage data while protecting customer privacy. Meter profile aggregation adds a layer of protection that decreases the risk of revealing CEUD as the number of meters aggregated increases. The report statistically characterizesmore » the similarity between individual energy usage patterns and whole-building totals at various levels of meter aggregation.« less
ENGINEERING TEST REACTOR, TRA642. CONTEXTUAL VIEW ORIENTATING ETR TO MTR. ...
ENGINEERING TEST REACTOR, TRA-642. CONTEXTUAL VIEW ORIENTATING ETR TO MTR. CAMERA IS ON ROOF OF MTR BUILDING AND FACES DUE SOUTH. MTR SERVICE BUILDING, TRA-635, IN LOWER RIGHT CORNER. STEEL FRAMES SHOW BUILDINGS TO BE ATTACHED TO ETR BUILDING. HIGH-BAY SECTION IN CENTER IS REACTOR BUILDING. TWO-STORY CONTROL ROOM AND OFFICE BUILDING, TRA-647, IS BETWEEN IT AND MTR SERVICE BUILDING. STRUCTURE TO THE LEFT (WITH NO FRAMING YET) IS COMPRESSOR BUILDING, TRA-643, AND BEYOND IT WILL BE HEAT EXCHANGER BUILDING, TRA-644, GREAT SOUTHERN BUTTE ON HORIZON. INL NEGATIVE NO. 56-2382. Jack L. Anderson, Photographer, 6/10/1956 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
An overview of solar energy applications in buildings in Greece
NASA Astrophysics Data System (ADS)
Papamanolis, Nikos
2016-09-01
This work classifies and describes the main fields of solar energy exploitation in buildings in Greece, a country with high solar energy capacities. The study focuses on systems and technologies that apply to residential and commercial buildings following the prevailing design and construction practices (conventional buildings) and investigates the effects of the architectural and constructional characteristics of these buildings on the respective applications. In addition, it examines relevant applications in other building categories and in buildings with increased ecological sensitivity in their design and construction (green buildings). Through its findings, the study seeks to improve the efficiency and broaden the scope of solar energy applications in buildings in Greece to the benefit of their energy and environmental performance.
NASA Astrophysics Data System (ADS)
Ljungberg, Sven-Ake
1995-03-01
Different building constructions and craftsmanship give rise to different thermal performance and damage conditions. The building stock of most industrial countries consists of buildings of various age, and constructions, from old historic buildings with heavy stone or wooden construction, to new buildings with heavy or light concrete construction, or modern steel or wooden construction. In this paper the result from a detailed infrared survey of 50 buildings from six Swedish military camps is presented. The presentation is limited to a comparison of thermal performance and damage conditions of buildings of various ages, functions, and constructions, of a building period of more than 100 years. The result is expected to be relevant even to civilian buildings. Infrared surveys were performed during 1992-1993, with airborne, and mobile short- and longwave infrared systems, out- and indoor thermography. Interpretation and analysis of infrared data was performed with interactive image and analyzing systems. Field inspections were carried out with fiber optics system, and by ocular inspections. Air-exchange rate was measured in order to quantify air leakages through the building envelope, indicated in thermograms. The objects studied were single-family houses, barracks, office-, service-, school- and exercise buildings, military hotels and restaurants, aircraft hangars, and ship factory buildings. The main conclusions from this study are that most buildings from 1880 - 1940 have a solid construction with a high quality of craftsmanship, relatively good thermal performance, due to extremely thick walls, and adding insulation at the attic floor. From about 1940 - 1960 the quality of construction, thermal performance and craftsmanship seem to vary a lot. Buildings constructed during the period of 1960 - 1990 have in general the best thermal performance due to a better insulation capacity, however, also one finds here the greatest variety of problems. The result from this study is to be incorporated in planning of short- and long term maintenance programs of the Swedish Defence. In general the military buildings are expected to have better status than civilian buildings, due to the more rigorous control during the building process, performed by military building authorities.
Re-Assessing Green Building Performance: A Post Occupancy Evaluation of 22 GSA Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fowler, Kimberly M.; Rauch, Emily M.; Henderson, Jordan W.
2010-06-01
2nd report on the performance of GSA's sustainably designed buildings. The purpose of this study was to provide an overview of measured whole building performance as it compares to GSA and industry baselines. The PNNL research team found the data analysis illuminated strengths and weaknesses of individual buildings as well as the portfolio of buildings. This section includes summary data, observations that cross multiple performance metrics, discussion of lessons learned from this research, and opportunities for future research. The summary of annual data for each of the performance metrics is provided in Table 25. The data represent 1 year ofmore » measurements and are not associated with any specific design features or strategies. Where available, multiple years of data were examined and there were minimal significant differences between the years. Individually focused post occupancy evaluation (POEs) would allow for more detailed analysis of the buildings. Examining building performance over multiple years could potentially offer a useful diagnostic tool for identifying building operations that are in need of operational changes. Investigating what the connection is between the building performance and the design intent would offer potential design guidance and possible insight into building operation strategies. The 'aggregate operating cost' metric used in this study represents the costs that were available for developing a comparative industry baseline for office buildings. The costs include water utilities, energy utilities, general maintenance, grounds maintenance, waste and recycling, and janitorial costs. Three of the buildings that cost more than the baseline in Figure 45 have higher maintenance costs than the baseline, and one has higher energy costs. Given the volume of data collected and analyzed for this study, the inevitable request is for a simple answer with respect to sustainably designed building performance. As previously stated, compiling the individual building values into single metrics is not statistically valid given the small number of buildings, but it has been done to provide a cursory view of this portfolio of sustainably designed buildings. For all metrics except recycling cost per rentable square foot and CBE survey response rate, the averaged building performance was better than the baseline for the GSA buildings in this study.« less
NASA Astrophysics Data System (ADS)
Rüther, Heinz; Martine, Hagai M.; Mtalo, E. G.
This paper presents a novel approach to semiautomatic building extraction in informal settlement areas from aerial photographs. The proposed approach uses a strategy of delineating buildings by optimising their approximate building contour position. Approximate building contours are derived automatically by locating elevation blobs in digital surface models. Building extraction is then effected by means of the snakes algorithm and the dynamic programming optimisation technique. With dynamic programming, the building contour optimisation problem is realized through a discrete multistage process and solved by the "time-delayed" algorithm, as developed in this work. The proposed building extraction approach is a semiautomatic process, with user-controlled operations linking fully automated subprocesses. Inputs into the proposed building extraction system are ortho-images and digital surface models, the latter being generated through image matching techniques. Buildings are modeled as "lumps" or elevation blobs in digital surface models, which are derived by altimetric thresholding of digital surface models. Initial windows for building extraction are provided by projecting the elevation blobs centre points onto an ortho-image. In the next step, approximate building contours are extracted from the ortho-image by region growing constrained by edges. Approximate building contours thus derived are inputs into the dynamic programming optimisation process in which final building contours are established. The proposed system is tested on two study areas: Marconi Beam in Cape Town, South Africa, and Manzese in Dar es Salaam, Tanzania. Sixty percent of buildings in the study areas have been extracted and verified and it is concluded that the proposed approach contributes meaningfully to the extraction of buildings in moderately complex and crowded informal settlement areas.
Collecting memories of the city through the conservation of heritage building
NASA Astrophysics Data System (ADS)
Nurliani Lukito, Yulia; Nurul Rizky, Amalia
2018-03-01
Heritage building has a role for the city and the society that is associated with emotional, cultural, and use values. Those values are parts of collective memory and create the identity of the city. Some heritage buildings are vulnerable to modernization and even when the government conserves those buildings, some important values of the buildings are lost. This paper discusses a colonial building in Jakarta that has been converted into different functions. As a case study is Cut Meutia Mosque in Menteng, designed by a Dutch architect PAJ Moojen during the Dutch late colonial era. The building was initiated in 1922 as N.V. Bouwploeg, an architectural firm that developed the nearby residential area of New Gondangdia. This area was developed according to modern Garden City principles and the Bouwploeg was known as the gate to Menteng area and the architecture of the building was considered very modern and unique at that time – illustrating the importance of the building for the city. After Indonesia’s independence, the government converted the building into different functions such as an office and a mosque. Although the function of the building has changed, the building is still related to triggering a collective memory of the new area that should not be ignored in the effort of conserving the building. Through historical and field research, the paper aims to discuss some changes and lost values of the building as the result of conserving the colonial heritage, especially about collective memory. Hopefully, learning from the conservation of building heritage and city collective memory may support the idea of livable memory of heritage building and even a
6. West side of Building 1001 (administration building), looking southeast ...
6. West side of Building 1001 (administration building), looking southeast - Naval Air Station Chase Field, Building 1001, Independence Street, .45 mile south of intersection of Texas State Highway & Independence Street, Beeville, Bee County, TX
4. South side of Building 1001 (administration building), looking north ...
4. South side of Building 1001 (administration building), looking north - Naval Air Station Chase Field, Building 1001, Independence Street, .45 mile south of intersection of Texas State Highway & Independence Street, Beeville, Bee County, TX
3. East side of Building 1001 (administration building), looking west ...
3. East side of Building 1001 (administration building), looking west - Naval Air Station Chase Field, Building 1001, Independence Street, .45 mile south of intersection of Texas State Highway & Independence Street, Beeville, Bee County, TX
5. North side of Building 1001 (administration building), looking southeast ...
5. North side of Building 1001 (administration building), looking southeast - Naval Air Station Chase Field, Building 1001, Independence Street, .45 mile south of intersection of Texas State Highway & Independence Street, Beeville, Bee County, TX
Kayenta Township Building & Safety Department, Tribal Green Building Code Summit Presentation
Tribal Green Building Code Summit Presentation by Kayenta Township Building & Safety Department showing how they established the building department, developed a code adoption and enforcement process, and hired staff to carry out the work.
23. SITE BUILDING 002 SCANNER BUILDING RADAR CONTROL ...
23. SITE BUILDING 002 - SCANNER BUILDING - RADAR CONTROL INTERFACE "RCL NO. 2" WITH COMPUTER CONTROL DISC DRIVE UNITS IN FOREGROUND. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
INTEGRATING HEALTH INTO BUILDINGS OF THE FUTURE
Heidari, Leila; Younger, Margalit; Chandler, George; Gooch, James; Schramm, Paul
2018-01-01
The health and wellbeing of building occupants should be a key priority in the design, building, and operation of new and existing buildings. Buildings can be designed, renovated, and constructed to promote healthy environments and behaviors and mitigate adverse health outcomes. This paper highlights health in terms of the relationship between occupants and buildings, as well as the relationship of buildings to the community. In the context of larger systems, smart buildings and green infrastructure strategies serve to support public health goals. At the level of the individual building, interventions that promote health can also enhance indoor environmental quality and provide opportunities for physical activity. Navigating the various programs that use metrics to measure a building’s health impacts reveals that there are multiple co-benefits of a “healthy building,” including those related to the economy, environment, society, transportation, planning, and energy efficiency. PMID:29375173
Building Energy Management Open Source Software
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rahman, Saifur
Funded by the U.S. Department of Energy in November 2013, a Building Energy Management Open Source Software (BEMOSS) platform was engineered to improve sensing and control of equipment in small- and medium-sized commercial buildings. According to the Energy Information Administration (EIA), small- (5,000 square feet or smaller) and medium-sized (between 5,001 to 50,000 square feet) commercial buildings constitute about 95% of all commercial buildings in the U.S. These buildings typically do not have Building Automation Systems (BAS) to monitor and control building operation. While commercial BAS solutions exist, including those from Siemens, Honeywell, Johnsons Controls and many more, they aremore » not cost effective in the context of small- and medium-sized commercial buildings, and typically work with specific controller products from the same company. BEMOSS targets small and medium-sized commercial buildings to address this gap.« less
Deep influence of passive low energy consumption multi-storey residential building in cold region
NASA Astrophysics Data System (ADS)
Shuai, Zhang; Lihua, Zhao; Rong, Jin; Dong, Junyan
2018-02-01
The example of passive architecture demonstration building in Jilin Province, China, based on the practical experience of this project, the control index of passive and low energy consumption residential buildings in cold and passive buildings is referenced by reference to the German construction standard and the Chinese residence construction document, “passive ultra-low energy consumption green Building Technology Guide (Trial)”. The requirement of passive low energy residential buildings on the ground heat transfer coefficient limits is determined, and the performance requirements of passive residential buildings are discussed. This paper analyzes the requirement of the passive low energy residential building on the ground heat transfer coefficient limit, and probes into the influence factors of the ground thermal insulation of the passive low energy consumption residential building. The construction method of passive low energy consumption residential building is proposed.
ERIC Educational Resources Information Center
National Bureau of Standards (DOC), Washington, DC. Inst. for Applied Technology.
The purpose of this report is to provide reference material on the technical options for energy conservation in buildings. Actions pertinent to existing buildings and new buildings are considered separately. Regarding existing buildings, principal topics include summer cooling, winter heating, and other energy-related features such as insulation,…
7. Building 7 interior, west end of building showing tier ...
7. Building 7 interior, west end of building showing tier of skylight windows and modern equipment. View looking west. - John & James Dobson Carpet Mill (West Parcel), Building No. 7, 4041-4055 Ridge Avenue, Philadelphia, Philadelphia County, PA
9. Interior of Building 1001 (administration building), Room 204, vault, ...
9. Interior of Building 1001 (administration building), Room 204, vault, looking east - Naval Air Station Chase Field, Building 1001, Independence Street, .45 mile south of intersection of Texas State Highway & Independence Street, Beeville, Bee County, TX
9. FERTILIZER PLANT AND STORAGE BUILDINGS, LOOKING EAST FROM BUILDING ...
9. FERTILIZER PLANT AND STORAGE BUILDINGS, LOOKING EAST FROM BUILDING 149; LIVESTOCK HOLDING BUILDINGS (HOG AND SHEEP HOTELS) OCCUPIED OPEN AREA IN FOREGROUND - Rath Packing Company, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-13
... Federal High-Performance Green Buildings; Green Building Advisory Committee; Notification of Upcoming... Green Building Advisory Committee Meeting (the Committee) and the schedule for a series of conference..., Designated Federal Officer, [[Page 56704
South and west (gable end) sides. Building 520 is to ...
South and west (gable end) sides. Building 520 is to either side in the background. - Fitzsimons General Hospital, X-ray Film Storage Building, East of Building No. 515, North of Building No. 517, Aurora, Adams County, CO
Contextual view of building, with building #12 in right background ...
Contextual view of building, with building #12 in right background and building #11 in right foreground. Camera facing east-southeast - Naval Supply Center, Broadway Complex, Administration Storehouse, 911 West Broadway, San Diego, San Diego County, CA
Elevation of pier building and main house looking south. Building ...
Elevation of pier building and main house looking south. Building at far right was fish smokehouse. Roof of building at right was used for drying fish. - Beacon Marine Basin, 211 East Main Street, Gloucester, Essex County, MA
58. MILL BUILDING (BUILDING 1558): VIEW FROM SOUTHWEST, WITH V2 ...
58. MILL BUILDING (BUILDING 1558): VIEW FROM SOUTHWEST, WITH V-2 ASSEMBLY BUILDING IN BACKGROUND AT FAR RIGHT - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM
56. V2 ASSEMBLY BUILDING (BUILDING 1538): VIEW FROM NORTHEAST, WITH ...
56. V-2 ASSEMBLY BUILDING (BUILDING 1538): VIEW FROM NORTHEAST, WITH MILL BUILDING IN BACKGROUND AT FAR RIGHT - White Sands Missile Range, V-2 Rocket Facilities, Near Headquarters Area, White Sands, Dona Ana County, NM
Credit BG. Northwest and southwest facades of Administration Building for ...
Credit BG. Northwest and southwest facades of Administration Building for Building 4505 area. Construction began on this building in 1967 - Edwards Air Force Base, North Base, Administration Building, Northeast of A Street, Boron, Kern County, CA
31. DETAILMETAL ROOF TRUSS OF THE NORTH WING OF BUILDING ...
31. DETAIL--METAL ROOF TRUSS OF THE NORTH WING OF BUILDING 36 LOOKING WEST TO THE WALL PARTITIONING BUILDING 36 AND BUILDING 33. - Navy Yard, Ordnance Building, Intersection of Paulding & Kennon Streets, Washington, District of Columbia, DC
Kosol Kiatreungwattana Kosol Kiatreungwattana Senior Engineer - Building and Renewable Energy experience in building energy systems and renewable technologies, building energy codes, LEED certified projects, sustainable high performance building design, building energy simulation analysis/optimization
1. BUILDING L (LEFT OF CENTER) EAST END AND SOUTH ...
1. BUILDING L (LEFT OF CENTER) EAST END AND SOUTH SIDE (BUILDING K IS ON RIGHT, BUILDING M IS ON LEFT), CAMERA FACING NORTHWEST - Buffalo Ranch, Office Building, 2418 MacArthur Boulevard, Irvine, Orange County, CA
Energy Conservation in Buildings--A Human Factors/Systems Viewpoint. NBS Building Science Series 88.
ERIC Educational Resources Information Center
Rubin, Arthur I.
The current emphasis on energy conservation in buildings must be balanced by a careful consideration of how proposed approaches affect building occupants. A headlong rush toward building designs that conserve energy at the expense of the quality of buildings as judged by occupants would be a very shortsighted approach. There must be a continual…
GENERAL VIEW OF TYPE HB54s (BUILDINGS T1088 TO T1093) & ...
GENERAL VIEW OF TYPE HB-54s (BUILDINGS T-1088 TO T-1093) & CONVERTED TYPE HB-54S (BUILDINGS T-1094 TO T-1096), LOOKING SOUTHWEST; BUILDING T-1088 AT LEFT, BUILDING T-1096 AT RIGHT - Fort McCoy, Building No. T-1096, South side of South Ninth Avenue, Block 10, Sparta, Monroe County, WI
2012-02-01
for Low Energy Building Ventilation and Space Conditioning Systems...Building Energy Models ................... 162 APPENDIX D: Reduced-Order Modeling and Control Design for Low Energy Building Systems .... 172 D.1...Design for Low Energy Building Ventilation and Space Conditioning Systems This section focuses on the modeling and control of airflow in buildings
Building Assessment Survey and Evaluation Study Summarized Data - HVAC Characteristics
In the Building Assessment Survey and Evaluation (BASE) Study Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues was acquired by examining the building plans, conducting a building walk-through, and speaking with the building owner, manager, and/or operator.
3. VIEW EAST OF MILL STREET BUILDINGS; 20 AT EXTREME ...
3. VIEW EAST OF MILL STREET BUILDINGS; 20 AT EXTREME LEFT CENTER; 21 AT MID-LEFT CENTER; 4 AT LEFT CENTER; RUNDBOGENSTIL TOWER AT CENTER; BUILDING 3 RIGHT CENTER; BUILDING 2 AT EXTREME RIGHT CENTER; BUILDING 3 IS THE OLDEST BUILDING ON SITE AND WAS BUILT CIRCA 1850 - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
72. PRISONER OF WAR AREA 'A,' BUILDINGS 7613, 7614, 7614, ...
72. PRISONER OF WAR AREA 'A,' BUILDINGS 7613, 7614, 7614, 7616, AND 7617, BARRACKS, AND BUILDING 7619, KITCHEN AND MESS HALL. (In the background, Building 7608, Guard Tower No. 4, is in front of Buildings 7502, 7503, and 7504, C.C.C. Storage Buildings). Fort McCoy photograph #B-37, undated. - Fort McCoy, Sparta, Monroe County, WI
Technology for Building Systems Integration and Optimization – Landscape Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goetzler, William; Guernsey, Matt; Bargach, Youssef
BTO's Commercial Building Integration (CBI) program helps advance a range of innovative building integration and optimization technologies and solutions, paving the way for high-performing buildings that could use 50-70% less energy than typical buildings. CBI’s work focuses on early stage technology innovation, with an emphasis on how components and systems work together and how whole buildings are integrated and optimized. This landscape study outlines the current body of knowledge, capabilities, and the broader array of solutions supporting integration and optimization in commercial buildings. CBI seeks to support solutions for both existing buildings and new construction, which often present very differentmore » challenges.« less
Country Report on Building Energy Codes in Canada
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shui, Bin; Evans, Meredydd
2009-04-06
This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America . This reports gives an overview of the development of building energy codes in Canada, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildingsmore » in Canada.« less
An international survey of building energy codes and their implementation
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
2017-08-01
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
Examining the impact of lahars on buildings using numerical modelling
NASA Astrophysics Data System (ADS)
Mead, Stuart R.; Magill, Christina; Lemiale, Vincent; Thouret, Jean-Claude; Prakash, Mahesh
2017-05-01
Lahars are volcanic flows containing a mixture of fluid and sediment which have the potential to cause significant damage to buildings, critical infrastructure and human life. The extent of this damage is controlled by properties of the lahar, location of elements at risk and susceptibility of these elements to the lahar. Here we focus on understanding lahar-induced building damage. Quantification of building damage can be difficult due to the complexity of lahar behaviour (hazard), varying number and type of buildings exposed to the lahar (exposure) and the uncertain susceptibility of buildings to lahar impacts (vulnerability). In this paper, we quantify and examine the importance of lahar hazard, exposure and vulnerability in determining building damage with reference to a case study in the city of Arequipa, Peru. Numerical modelling is used to investigate lahar properties that are important in determining the inundation area and forces applied to buildings. Building vulnerability is quantified through the development of critical depth-pressure curves based on the ultimate bending moment of masonry structures. In the case study area, results suggest that building strength plays a minor role in determining overall building losses in comparison to the effects of building exposure and hydraulic characteristics of the lahar.
An international survey of building energy codes and their implementation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Roshchanka, Volha; Graham, Peter
Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less
Scalar Fluxes Near a Tall Building in an Aligned Array of Rectangular Buildings
NASA Astrophysics Data System (ADS)
Fuka, Vladimír; Xie, Zheng-Tong; Castro, Ian P.; Hayden, Paul; Carpentieri, Matteo; Robins, Alan G.
2018-04-01
Scalar dispersion from ground-level sources in arrays of buildings is investigated using wind-tunnel measurements and large-eddy simulation (LES). An array of uniform-height buildings of equal dimensions and an array with an additional single tall building (wind tunnel) or a periodically repeated tall building (LES) are considered. The buildings in the array are aligned and form long streets. The sensitivity of the dispersion pattern to small changes in wind direction is demonstrated. Vertical scalar fluxes are decomposed into the advective and turbulent parts and the influences of wind direction and of the presence of the tall building on the scalar flux components are evaluated. In the uniform-height array turbulent scalar fluxes are dominant, whereas the tall building produces an increase of the magnitude of advective scalar fluxes that yields the largest component. The presence of the tall building causes either an increase or a decrease to the total vertical scalar flux depending on the position of the source with respect to the tall building. The results of the simulations can be used to develop parametrizations for street-canyon dispersion models and enhance their capabilities in areas with tall buildings.
Data-Driven Benchmarking of Building Energy Efficiency Utilizing Statistical Frontier Models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kavousian, A; Rajagopal, R
2014-01-01
Frontier methods quantify the energy efficiency of buildings by forming an efficient frontier (best-practice technology) and by comparing all buildings against that frontier. Because energy consumption fluctuates over time, the efficiency scores are stochastic random variables. Existing applications of frontier methods in energy efficiency either treat efficiency scores as deterministic values or estimate their uncertainty by resampling from one set of measurements. Availability of smart meter data (repeated measurements of energy consumption of buildings) enables using actual data to estimate the uncertainty in efficiency scores. Additionally, existing applications assume a linear form for an efficient frontier; i.e.,they assume that themore » best-practice technology scales up and down proportionally with building characteristics. However, previous research shows that buildings are nonlinear systems. This paper proposes a statistical method called stochastic energy efficiency frontier (SEEF) to estimate a bias-corrected efficiency score and its confidence intervals from measured data. The paper proposes an algorithm to specify the functional form of the frontier, identify the probability distribution of the efficiency score of each building using measured data, and rank buildings based on their energy efficiency. To illustrate the power of SEEF, this paper presents the results from applying SEEF on a smart meter data set of 307 residential buildings in the United States. SEEF efficiency scores are used to rank individual buildings based on energy efficiency, to compare subpopulations of buildings, and to identify irregular behavior of buildings across different time-of-use periods. SEEF is an improvement to the energy-intensity method (comparing kWh/sq.ft.): whereas SEEF identifies efficient buildings across the entire spectrum of building sizes, the energy-intensity method showed bias toward smaller buildings. The results of this research are expected to assist researchers and practitioners compare and rank (i.e.,benchmark) buildings more robustly and over a wider range of building types and sizes. Eventually, doing so is expected to result in improved resource allocation in energy-efficiency programs.« less
Identifying Populace Susceptible to Flooding Using ArcGIS and Remote Sensing Datasets
NASA Astrophysics Data System (ADS)
Fernandez, Sim Joseph; Milano, Alan
2016-07-01
Remote sensing technologies are growing vastly as with its various applications. The Department of Science and Technology (DOST), Republic of the Philippines, has made projects exploiting LiDAR datasets from remote sensing technologies. The Phil-LiDAR 1 project of DOST is a flood hazard mapping project. Among the project's objectives is the identification of building features which can be associated to the flood-exposed population. The extraction of building features from the LiDAR dataset is arduous as it requires manual identification of building features on an elevation map. The mapping of building footprints is made meticulous in order to compensate the accuracy between building floor area and building height both of which are crucial in flood decision making. A building identification method was developed to generate a LiDAR derivative which will serve as a guide in mapping building footprints. The method utilizes several tools of a Geographic Information System (GIS) software called ArcGIS which can operate on physical attributes of buildings such as roofing curvature, slope and blueprint area in order to obtain the LiDAR derivative from LiDAR dataset. The method also uses an intermediary process called building removal process wherein buildings and other features lying below the defined minimum building height - 2 meters in the case of Phil-LiDAR 1 project - are removed. The building identification method was developed in the hope to hasten the identification of building features especially when orthophotographs and/or satellite imageries are not made available.
Evaluating the Maturity of Cybersecurity Programs for Building Control Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glantz, Clifford S.; Somasundaram, Sriram; Mylrea, Michael E.
The cyber-physical security threat to buildings is complex, non-linear, and rapidly evolving as operational and information technologies converge and connect buildings to cyberspace. Cyberattacks on buildings can exploit smart building controls and breach corporate networks, causing financial and reputational damage. This may result in the loss of sensitive building information or the disruption of, or damage to, the systems necessary for the safe and efficient operation of buildings. For the buildings and facility infrastructure, there is a need for a robust national cybersecurity strategy for buildings, guidance on the selection and implementation of appropriate cybersecurity controls for buildings, an approachmore » to evaluate the maturity and adequacy of the cybersecurity programs. To provide an approach for evaluating the maturity of the cybersecurity programs for building control systems, the US Department of Energy’s widely used Cybersecurity Capability and Maturity Model (C2M2) has been adapted into a building control systems version. The revised model, the Buildings-C2M2 (B-C2M2) provides maturity level indicators for cybersecurity programmatic domains. A “B-C2M2 Lite” version allows facility managers and building control system engineers, or information technology personnel to perform rapid self-assessments of their cybersecurity program. Both tools have been pilot tested on several facilities. This paper outlines the concept of a maturity model, describes the B-C2M2 tools, presents results and observations from the pilot assessments, and lays out plans for future work.« less
9. BUILDING NO. 620B, FRICTION PENDULUM BUILDING. 29FOOT DROP TOWER ...
9. BUILDING NO. 620-B, FRICTION PENDULUM BUILDING. 29-FOOT DROP TOWER SITS BEHIND BLAST SHIELD IN FRONT OF BUILDING. - Picatinny Arsenal, 600 Area, Test Areas District, State Route 15 near I-80, Dover, Morris County, NJ
Exterior building details of Building B, east façade: ca. 1914 ...
Exterior building details of Building B, east façade: ca. 1914 covered porch with an asphalt singled low-hipped roof; southwesterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Exterior building details of Building E, oblique west façade: brick ...
Exterior building details of Building E, oblique west façade: brick arch lintel and brick infilled window with brick sill; southeasterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Old Riverdale Cotton Mill office building on left. The old ...
Old Riverdale Cotton Mill office building on left. The old office building has also been used as a starch mixing house. Note entrance to new office building on right - Riverdale Cotton Mill, Office Building, Old, Valley, Chambers County, AL
8. VIEW EASTNORTHEAST OF TRANSFORMER BAYS AND SUBSTATION; BUILDING 8 ...
8. VIEW EAST-NORTHEAST OF TRANSFORMER BAYS AND SUB-STATION; BUILDING 8 IS AT EXTREME LEFT CENTER; BUILD-ING 50 IS VISIBLE AT LEFT CENTER BEHIND BUILDING 8 - Scovill Brass Works, 59 Mill Street, Waterbury, New Haven County, CT
Interior building details of Building C, Room C203 to Room ...
Interior building details of Building C, Room C-203 to Room C-204: historical partition track with folding doors, east painted wall; easterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
1. OVERALL VIEW OF BUILDING 9, LOOKING TO SOUTHEAST FROM ...
1. OVERALL VIEW OF BUILDING 9, LOOKING TO SOUTHEAST FROM BUILDING 4. BUILDING 2 IS VISIBLE BEHIND AND TO LEFT OF BUILDING 9. - U.S. Geological Survey, Rock Magnetics Laboratory, 345 Middlefield Road, Menlo Park, San Mateo County, CA
Building 909, oblique view to southeast, 135 mm lens. Building ...
Building 909, oblique view to southeast, 135 mm lens. Building 908 at extreme right for context. - Travis Air Force Base, Handling Crew Building, North of W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malhotra, Mini; New, Joshua Ryan; Im, Piljae
As part of DOE's support of ANSI/ASHRAE/IES Standard 90.1 and IECC, researchers at Pacific Northwest National Laboratory (PNNL) apply a suite of prototype buildings covering 80% of the commercial building floor area in the U.S. for new construction. Efforts have started on expanding the prototype building suite to cover 90% of the commercial building floor area in the U.S., by developing prototype models for additional building types including place of worship, public order and safety, public assembly. Courthouse is courthouse is a sub-category under the “Public Order and Safety" building type category; other sub-categories include police station, fire station, andmore » jail, reformatory or penitentiary.ORNL used building design guides, databases, and documented courthouse projects, supplemented by personal communication with courthouse facility planning and design experts, to systematically conduct research on the courthouse building and system characteristics. This report documents the research conducted for the courthouse building type and proposes building and system characteristics for developing a prototype building energy model to be included in the Commercial Building Prototype Model suite. According to the 2012 CBECS, courthouses occupy a total of 436 million sqft of floor space or 0.5% of the total floor space in all commercial buildings in the US, next to fast food (0.35%), grocery store or food market (0.88%), and restaurant or cafeteria (1.2%) building types currently included in the Commercial Prototype Building Model suite. Considering aggregated average, courthouse falls among the larger with a mean floor area of 69,400 sqft smaller fuel consumption intensity building types and an average of 94.7 kBtu/sqft compared to 77.8 kBtu/sqft for office and 80 kBtu/sqft for all commercial buildings.Courthouses range in size from 1000 sqft to over a million square foot building gross square feet and 1 courtroom to over 100 courtrooms. Small courthouses represent a majority of courthouse buildings. However, collectively they comprise a small fraction of total courthouse floor area in the US. Spaces and operation of courthouse also varies depending on the court type (federal court vs state court; district, appellate, versus Supreme Court) and jurisdiction (general jurisdiction, general jurisdiction trial, or special courts). Based on the statistics on courthouses, general jurisdiction trial court is considered for the prototype model. The model is assumed to be a 4-courtroom, small, 72,000 sqft three-story building including a ground level/ basement.« less
Data and Analytics to Inform Energy Retrofit of High Performance Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Tianzhen; Yang, Le; Hill, David
Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energymore » audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.« less
An Experimental Test of Factors Attracting Deer Mice into Buildings.
Kuenzi, Amy J; Douglass, Richard
2009-09-01
Deer mice (Peromyscus maniculatus) are the principal reservoir host of Sin Nombre virus (SNV). Deer mice use a wide variety of habitats including peridomestic settings in and around human dwellings, their presence in and around homes has been implicated as a risk factor for acquiring Hantavirus Pulmonary Syndrome. Deer mice are believed to enter buildings in order to gain access to a variety of resources including food, bedding material, and better thermal microclimates. However, no one has experimentally tested which factors influence mice use of buildings. We conducted experiments using small simulated buildings to determine the effects of two factors, i.e., food and bedding material, on mouse activity in these buildings. We also examined if these effects varied with time of year. We found that deer mice entered our buildings regardless of the presence or absence of food or bedding. However, the amount of activity in buildings was affected by what they contained. We found significantly higher indices of activity in buildings containing food compared to both empty buildings (control) and buildings containing bedding material. Time of year did not affect activity in buildings.
Airborne asbestos in public buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chesson, J.; Hatfield, J.; Schultz, B.
The U.S. Environmental Protection Agency sampled air in 49 government-owned buildings (six buildings with no asbestos-containing material, six buildings with asbestos-containing material in generally good condition, and 37 buildings with damaged asbestos-containing material). This is the most comprehensive study to date of airborne asbestos levels in U.S. public buildings during normal building activities. The air outside each building was also sampled. Air samples were analyzed by transmission electron microscopy using a direct transfer preparation technique. The results show an increasing trend in average airborne asbestos levels; outdoor levels are lowest and levels in buildings with damaged asbestos-containing material are highest.more » However, the measured levels and the differences between indoors and outdoors and between building categories are small in absolute magnitude. Comparable studies from Canada and the UK, although differing in their estimated concentrations, also conclude that while airborne asbestos levels may be elevated in buildings that contain asbestos, levels are generally low. This conclusion does not eliminate the possibility of higher airborne asbestos levels during maintenance or renovation that disturbs the asbestos-containing material.« less
Attributes of the Federal Energy Management Program's Federal Site Building Characteristics Database
DOE Office of Scientific and Technical Information (OSTI.GOV)
Loper, Susan A.; Sandusky, William F.
2010-12-31
Typically, the Federal building stock is referred to as a group of about one-half million buildings throughout the United States. Additional information beyond this level is generally limited to distribution of that total by agency and maybe distribution of the total by state. However, additional characterization of the Federal building stock is required as the Federal sector seeks ways to implement efficiency projects to reduce energy and water use intensity as mandated by legislation and Executive Order. Using a Federal facility database that was assembled for use in a geographic information system tool, additional characterization of the Federal building stockmore » is provided including information regarding the geographical distribution of sites, building counts and percentage of total by agency, distribution of sites and building totals by agency, distribution of building count and floor space by Federal building type classification by agency, and rank ordering of sites, buildings, and floor space by state. A case study is provided regarding how the building stock has changed for the Department of Energy from 2000 through 2008.« less
Streamlining Building Efficiency Evaluation with DOE's Asset Score Preview
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goel, Supriya; Wang, Nora; Gonzalez, Juan
2016-08-26
Building Energy Asset Score (Asset Score), developed by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE), is a tool to help building owners and managers assess the efficiency of a building's energy-related systems and encourage investment in cost-effective improvements. The Asset Score uses an EnergyPlus model to provide a quick assessment of building energy performance with minimum user inputs of building characteristics and identifies upgrade opportunities. Even with a reduced set of user inputs, data collection remains a challenge for wide-spread adoption, especially when evaluating a large number of buildings. To address this, Asset Scoremore » Preview was developed to allow users to enter as few as seven building characteristics to quickly assess their buildings before a more in-depth analysis. A streamlined assessment from Preview to full Asset Score provides an easy entry point and also enables users who manage a large number of buildings to screen and prioritize buildings that can benefit most from a more detailed evaluation and possible energy efficiency upgrades without intensive data collection.« less
NASA Astrophysics Data System (ADS)
Heidarinejad, Mohammad
This dissertation develops rapid and accurate building energy simulations based on a building classification that identifies and focuses modeling efforts on most significant heat transfer processes. The building classification identifies energy use patterns and their contributing parameters for a portfolio of buildings. The dissertation hypothesis is "Building classification can provide minimal required inputs for rapid and accurate energy simulations for a large number of buildings". The critical literature review indicated there is lack of studies to (1) Consider synoptic point of view rather than the case study approach, (2) Analyze influence of different granularities of energy use, (3) Identify key variables based on the heat transfer processes, and (4) Automate the procedure to quantify model complexity with accuracy. Therefore, three dissertation objectives are designed to test out the dissertation hypothesis: (1) Develop different classes of buildings based on their energy use patterns, (2) Develop different building energy simulation approaches for the identified classes of buildings to quantify tradeoffs between model accuracy and complexity, (3) Demonstrate building simulation approaches for case studies. Penn State's and Harvard's campus buildings as well as high performance LEED NC office buildings are test beds for this study to develop different classes of buildings. The campus buildings include detailed chilled water, electricity, and steam data, enabling to classify buildings into externally-load, internally-load, or mixed-load dominated. The energy use of the internally-load buildings is primarily a function of the internal loads and their schedules. Externally-load dominated buildings tend to have an energy use pattern that is a function of building construction materials and outdoor weather conditions. However, most of the commercial medium-sized office buildings have a mixed-load pattern, meaning the HVAC system and operation schedule dictate the indoor condition regardless of the contribution of internal and external loads. To deploy the methodology to another portfolio of buildings, simulated LEED NC office buildings are selected. The advantage of this approach is to isolate energy performance due to inherent building characteristics and location, rather than operational and maintenance factors that can contribute to significant variation in building energy use. A framework for detailed building energy databases with annual energy end-uses is developed to select variables and omit outliers. The results show that the high performance office buildings are internally-load dominated with existence of three different clusters of low-intensity, medium-intensity, and high-intensity energy use pattern for the reviewed office buildings. Low-intensity cluster buildings benefit from small building area, while the medium- and high-intensity clusters have a similar range of floor areas and different energy use intensities. Half of the energy use in the low-intensity buildings is associated with the internal loads, such as lighting and plug loads, indicating that there are opportunities to save energy by using lighting or plug load management systems. A comparison between the frameworks developed for the campus buildings and LEED NC office buildings indicates these two frameworks are complementary to each other. Availability of the information has yielded to two different procedures, suggesting future studies for a portfolio of buildings such as city benchmarking and disclosure ordinance should collect and disclose minimal required inputs suggested by this study with the minimum level of monthly energy consumption granularity. This dissertation developed automated methods using the OpenStudio API (Application Programing Interface) to create energy models based on the building class. ASHRAE Guideline 14 defines well-accepted criteria to measure accuracy of energy simulations; however, there is no well-accepted methodology to quantify the model complexity without the influence of the energy modeler judgment about the model complexity. This study developed a novel method using two weighting factors, including weighting factors based on (1) computational time and (2) easiness of on-site data collection, to measure complexity of the energy models. Therefore, this dissertation enables measurement of both model complexity and accuracy as well as assessment of the inherent tradeoffs between energy simulation model complexity and accuracy. The results of this methodology suggest for most of the internal load contributors such as operation schedules the on-site data collection adds more complexity to the model compared to the computational time. Overall, this study provided specific data on tradeoffs between accuracy and model complexity that points to critical inputs for different building classes, rather than an increase in the volume and detail of model inputs as the current research and consulting practice indicates. (Abstract shortened by UMI.).
NASA Astrophysics Data System (ADS)
Li, Xiwang
Buildings consume about 41.1% of primary energy and 74% of the electricity in the U.S. Moreover, it is estimated by the National Energy Technology Laboratory that more than 1/4 of the 713 GW of U.S. electricity demand in 2010 could be dispatchable if only buildings could respond to that dispatch through advanced building energy control and operation strategies and smart grid infrastructure. In this study, it is envisioned that neighboring buildings will have the tendency to form a cluster, an open cyber-physical system to exploit the economic opportunities provided by a smart grid, distributed power generation, and storage devices. Through optimized demand management, these building clusters will then reduce overall primary energy consumption and peak time electricity consumption, and be more resilient to power disruptions. Therefore, this project seeks to develop a Net-zero building cluster simulation testbed and high fidelity energy forecasting models for adaptive and real-time control and decision making strategy development that can be used in a Net-zero building cluster. The following research activities are summarized in this thesis: 1) Development of a building cluster emulator for building cluster control and operation strategy assessment. 2) Development of a novel building energy forecasting methodology using active system identification and data fusion techniques. In this methodology, a systematic approach for building energy system characteristic evaluation, system excitation and model adaptation is included. The developed methodology is compared with other literature-reported building energy forecasting methods; 3) Development of the high fidelity on-line building cluster energy forecasting models, which includes energy forecasting models for buildings, PV panels, batteries and ice tank thermal storage systems 4) Small scale real building validation study to verify the performance of the developed building energy forecasting methodology. The outcomes of this thesis can be used for building cluster energy forecasting model development and model based control and operation optimization. The thesis concludes with a summary of the key outcomes of this research, as well as a list of recommendations for future work.
Analysis and Optimization of Building Energy Consumption
NASA Astrophysics Data System (ADS)
Chuah, Jun Wei
Energy is one of the most important resources required by modern human society. In 2010, energy expenditures represented 10% of global gross domestic product (GDP). By 2035, global energy consumption is expected to increase by more than 50% from current levels. The increased pace of global energy consumption leads to significant environmental and socioeconomic issues: (i) carbon emissions, from the burning of fossil fuels for energy, contribute to global warming, and (ii) increased energy expenditures lead to reduced standard of living. Efficient use of energy, through energy conservation measures, is an important step toward mitigating these effects. Residential and commercial buildings represent a prime target for energy conservation, comprising 21% of global energy consumption and 40% of the total energy consumption in the United States. This thesis describes techniques for the analysis and optimization of building energy consumption. The thesis focuses on building retrofits and building energy simulation as key areas in building energy optimization and analysis. The thesis first discusses and evaluates building-level renewable energy generation as a solution toward building energy optimization. The thesis next describes a novel heating system, called localized heating. Under localized heating, building occupants are heated individually by directed radiant heaters, resulting in a considerably reduced heated space and significant heating energy savings. To support localized heating, a minimally-intrusive indoor occupant positioning system is described. The thesis then discusses occupant-level sensing (OLS) as the next frontier in building energy optimization. OLS captures the exact environmental conditions faced by each building occupant, using sensors that are carried by all building occupants. The information provided by OLS enables fine-grained optimization for unprecedented levels of energy efficiency and occupant comfort. The thesis also describes a retrofit-oriented building energy simulator, ROBESim, that natively supports building retrofits. ROBESim extends existing building energy simulators by providing a platform for the analysis of novel retrofits, in addition to simulating existing retrofits. Using ROBESim, retrofits can be automatically applied to buildings, obviating the need for users to manually update building characteristics for comparisons between different building retrofits. ROBESim also includes several ease-of-use enhancements to support users of all experience levels.
Energy simulation and optimization for a small commercial building through Modelica
NASA Astrophysics Data System (ADS)
Rivas, Bryan
Small commercial buildings make up the majority of buildings in the United States. Energy consumed by these buildings is expected to drastically increase in the next few decades, with a large percentage of the energy consumed attributed to cooling systems. This work presents the simulation and optimization of a thermostat schedule to minimize energy consumption in a small commercial building test bed during the cooling season. The simulation occurs through the use of the multi-engineering domain Dymola environment based on the Modelica open source programming language and is optimized with the Java based optimization program GenOpt. The simulation uses both physically based modeling utilizing heat transfer principles for the building and regression analysis for energy consumption. GenOpt is dynamically coupled to Dymola through various interface files. There are very few studies that have coupled GenOpt to a building simulation program and even fewer studies have used Dymola for building simulation as extensively as the work presented here. The work presented proves Dymola as a viable alternative to other building simulation programs such as EnergyPlus and MatLab. The model developed is used to simulate the energy consumption of a test bed, a commissioned real world small commercial building, while maintaining indoor thermal comfort. Potential applications include smart or intelligent building systems, predictive simulation of small commercial buildings, and building diagnostics.
Resilient design in the conservation of Johar market heritage building
NASA Astrophysics Data System (ADS)
Roesmanto, Totok
2017-12-01
Johar Market building based on Law of Repubic of Indonesia No.11 of 2010 is a heritage building. It was built in 1936 located near traditional square of Pasebaan and Aloon- Aloon was built by Dutch merchants union in 1678. Semarang based on decentralized policy by the Dutch Government in 1906 became a trading city. Rapid development of trading activities has caused the city planning policy by Semarang Government since 1970 made Aloon-Aloon become market buildings. Johar Market and market buildings in surrounding were on fire in 2015. Basing on Law No.11 of 2010 Semarang Government plans to conserve Johar Market heritage building and reconstruct Aloon-Aloon based on proposal of Roesmanto in 2016. The architect bureau assigned by the Semarang Government designed a new building in the middle of South-Johar Market to accommodate Johar merchants. This study aims to evaluate the design of new building by the architect bureau considering that since 2012 the city of Semarang including earthquake prone areas. The revitalization of Johar Market should use resilient design in order to prevent future damages to heritage buildings located nearby and new building must be spaced sufficiently against surrounding heritage buildings. This research uses descriptive qualitative method base on the field data after Johar Market burned and design planned bureau architect. The results of this study found that the distance between new building and heritage building is less wide.
2015-01-01
The 2012 CBECS collected building characteristics data from more than 6,700 U.S. commercial buildings. This report highlights findings from the survey, with details presented in the Building Characteristics tables.
75 FR 52671 - YouthBuild Program
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-27
... required by green building and weatherization industries but are not yet standardized. A full list of the...Build Program AGENCY: Employment and Training Administration, Labor. ACTION: Notice of proposed...Build Transfer Act of 2006 (Transfer Act), which establishes the YouthBuild program in the Department...
Interior building details of Building B, Room B001: fouroverfour wood ...
Interior building details of Building B, Room B-001: four-over-four wood painted wood with brick sill and painted plaster west brick wall; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Building Trades. Block II. Foundations.
ERIC Educational Resources Information Center
Texas A and M Univ., College Station. Vocational Instructional Services.
Twelve informational lessons and eleven manipulative lessons are provided on foundations as applied to the building trades. Informational lessons cover land measurements; blueprint reading; level instruments; building and site planning; building site preparation; laying out building lines; soil preparation and special evacuation; concrete forms;…
14 CFR Section 3 - Chart of Balance Sheet Accounts
Code of Federal Regulations, 2014 CFR
2014-01-01
... buildings and equipment 1639 1739 General classification Buildings 1640 1740 Maintenance buildings and... 1654 1754 Furniture, fixtures, and office equipment 1656 1756 Buildings 1660 1760 Maintenance buildings... 1510.3 Other investments and receivables 1530 Special funds 1550 Property and equipment 1600-1700...
14 CFR Section 3 - Chart of Balance Sheet Accounts
Code of Federal Regulations, 2013 CFR
2013-01-01
... buildings and equipment 1639 1739 General classification Buildings 1640 1740 Maintenance buildings and... 1654 1754 Furniture, fixtures, and office equipment 1656 1756 Buildings 1660 1760 Maintenance buildings... 1510.3 Other investments and receivables 1530 Special funds 1550 Property and equipment 1600-1700...
14 CFR 3 - Chart of Balance Sheet Accounts
Code of Federal Regulations, 2012 CFR
2012-01-01
... buildings and equipment 1639 1739 General classification Buildings 1640 1740 Maintenance buildings and... 1654 1754 Furniture, fixtures, and office equipment 1656 1756 Buildings 1660 1760 Maintenance buildings... 1510.3 Other investments and receivables 1530 Special funds 1550 Property and equipment 1600-1700...
3. View of Building 802 from the Guard Shack (Building ...
3. View of Building 802 from the Guard Shack (Building 801), Buildings 800 and 804 beside, facing north. - Naval Air Station Fallon, 100-man Fallout Shelter, 800 Complex, off Carson Road near intersection of Pasture & Berney Roads, Fallon, Churchill County, NV
Building America Top Innovations 2013 Profile – Building America Solution Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
none,
2013-09-01
This Top Innovation profile provides information about the Building America Solution Center created by Pacific Northwest National Laboratory, a web tool connecting users to thousands of pieces of building science information developed by DOE’s Building America research partners.
Trends in Public Library Buildings.
ERIC Educational Resources Information Center
Holt, Raymond M.
1987-01-01
Review of trends in public library buildings covers cycles in building activity; financial support; site selection; expansion, remodeling, or conversion of existing buildings; size of buildings; and such architectural concerns as flexible space, lighting, power, accommodation of computer systems, heat and ventilation, fire protection, security,…
3. Building J interior, ground floor, looking northwest toward Building ...
3. Building J interior, ground floor, looking northwest toward Building L and showing clerestory. Portion to left of clerestory has an upper floor. - Daniel F. Waters Germantown Dye Works, Building J, 37-55 East Wister Street, Philadelphia, Philadelphia County, PA
5. SITE BUILDING 002 SCANNER BUILDING AT "A" ...
5. SITE BUILDING 002 - SCANNER BUILDING - AT "A" FACE (ON SOUTH SIDE) LOOKING DIRECTLY UP RADAR SYSTEM EMITTER/ANTENNA ARRAY FACE WITH 90MM STANDARD LENS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Interior building details of Building A, dungeon cell adjacent to ...
Interior building details of Building A, dungeon cell adjacent to northwest cell: granite and brick threshold, poured concrete floors, plastered finished walls, vaulted veiling; northwesterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
1. VIEW, LOOKING NORTH, NORTH OF PORTAL 1, JUST INSIDE ...
1. VIEW, LOOKING NORTH, NORTH OF PORTAL 1, JUST INSIDE THE PROTECTED AREA. ON THE LEFT SIDE OF THE PHOTOGRAPH IS BUILDING 709, THE COOLING TOWER FOR BUILDING 707, AND BEHIND BUILDING 709 IS BUILDING 707, THE NEWEST OF THE PLUTONIUM FABRICATION BUILDINGS. IN THE RIGHT FOREGROUND IS BUILDING 763, A BREEZEWAY FOR PEDESTRIANS. IN THE FAR LEFT OF THE PHOTOGRAPH ARE THE T750 TRAILERS AND BUILDING 750, THE PRODUCTION SUPPORT ENGINEERING FACILITY. - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
2. VIEW, LOOKING NORTHWEST, FROM INSIDE THE PROTECTED AREA AT ...
2. VIEW, LOOKING NORTHWEST, FROM INSIDE THE PROTECTED AREA AT THE BASE OF TOWER 901. THE BUILDINGS IN THE FOREGROUND INCLUDE 984, 992, 991, 989, AND 968. THESE BUILDINGS MAKE UP THE BUILDING 991 COMPLEX. BUILDING 991, PLANT D, WAS THE FIRST OPERATIONAL BUILDING ON SITE, CONSTRUCTED IN 1951 AS THE FINAL ASSEMBLY AND SHIPPING AND RECEIVING BUILDING. TO THE NORTH AND NORTHWEST OF BUILDING 991 ARE THE UNDERGROUND VAULTS AND TUNNELS USED TO STORAGE WEAPONS COMPONENTS. - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1984-03-01
The objectives of the analysis are to evaluate the application of a number of building automation system capabilities using the Park Plaza Building as a case study. The study looks at the energy and cost effectiveness of some energy management strategies of the building automation system as well as some energy management strategies that are not currently a part of the building automation system. The strategies are also evaluated in terms of their reliability and usefulness in this building.
Analysis for Building Envelopes and Mechanical Systems Using 2012 CBECS Data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winiarski, David W.; Halverson, Mark A.; Butzbaugh, Joshua B.
This report describes the aggregation and mapping of certain building characteristics data available in the most recent Commercial Building Energy Consumption Survey (CBECS) (DOE EIA 2012) to describe most typical building construction practices. This report provides summary data for potential use in the support of modifications to the Pacific Northwest National Laboratory’s commercial building prototypes used for building energy code analysis. Specifically, this report outlines findings and most typical design choices for certain building envelope and heating, ventilating, and air-conditioning (HVAC) system choices.
GEM Building Taxonomy (Version 2.0)
Brzev, S.; Scawthorn, C.; Charleson, A.W.; Allen, L.; Greene, M.; Jaiswal, Kishor; Silva, V.
2013-01-01
/7/8/IRRE9/10/RSH3+RWO211/FW12/13/ which can be read as (1) Direction = [DX or DY] (the building has the same lateral load-resisting system in both directions); (2) Material = [Unreinforced Masonry + solid fired clay bricks + cement: lime mortar]; (3) Lateral Load-Resisting System = [Wall]; (4) Date of construction = [pre-1939]; (5) Heaight = [exactly 2 storeys]; (6) Occupancy = [residential, unknown type]; (7) Building Position = [unknown = no entry]; (8) Shape of building plan = [unknown = no entry]; (9) Structural irregularity = [regular]; (10) Exterior walls = [unknown = no entry]; (11) Roof = [Shape: pitched and hipped, Roof covering: clay tiles, Roof system material: wood, Roof system type: wood trusses]; (12) Floor = [Floor system: Wood, unknown]; (13) Foundation = [unknown = no entry]. Mapping of GEM Building Taxonomy to selected taxonomies is included in the report -- for example, the above building would be referenced by previous structural taxonomies as: PAGER-STR as UFB or UFB4, by the World Housing Encyclopedia as 7 or 8 and by the European Macroseismic Scale (98) as M5. The Building Taxonomy data model is highly flexible and has been incorporated within a relational database architecture. Due to its ability to represent building typologies using a shorthand form, it is also possible to use the taxonomy for non-database applications, and we discuss possible application of adaptation for Building Information Modelling (BIM) systems, and for the insurance industry. The GEM Building Taxonomy was independently evaluated and tested by the Earthquake Engineering Research Institute (EERI), which received 217 TaxT reports from 49 countries, representing a wide range of building typologies, including single and multi-storey buildings, reinforced and unreinforced masonry, confined masonry, concrete, steel, wood, and earthern buildings used for residential, commercial, industrial, and educational occupancy. Based on these submissions and other feedback, the EERI team validated that the GEM Building Taxonomy is highly functional, robust and able to describe different buildings around the world. The GEM Building Taxonomy is accompanied by supplementary resources. All terms have been explained in a companion online Glossary, which provides both text and graphic descriptions. The Taxonomy is accompanied by TaxT, a computer application that enables a user record information about a building or a building typology using the attributes of the GEM Building Taxonomy v2.0. TaxT can generate a taxonomy string and enable a user to generate a report in PDF format which summarizes the attribute values (s)he has chosen as representative of the building typology under consideration. The report concludes with recommendations for future development of the GEM Building Taxonomy. Appendices provide the detailed GEM Building Taxonomy tables and additional resource, as well as mappings to other taxonomies.
Brown, Michael J; Williams, Michael D; Nelson, Matthew A; Werley, Kenneth A
2015-01-01
The Quick Urban and Industrial Complex (QUIC) plume modeling system is used to explore how the transport and dispersion of vehicle emissions in cities are impacted by the presence of buildings. Using downtown Philadelphia as a test case, notional vehicle emissions of gases and particles are specified as line source releases on a subset of the east-west and north-south streets. Cases were run in flat terrain and with 3D buildings present in order to show the differences in the model-computed outdoor concentration fields with and without buildings present. The QUIC calculations show that buildings result in regions with much higher concentrations and other areas with much lower concentrations when compared to the flat-earth case. On the roads with vehicle emissions, street-level concentrations were up to a factor of 10 higher when buildings were on either side of the street as compared to the flat-earth case due to trapping of pollutants between buildings. However, on roads without vehicle emissions and in other open areas, the concentrations were up to a factor of 100 times smaller as compared to the flat earth case because of vertical mixing of the vehicle emissions to building height in the cavity circulation that develops on the downwind side of unsheltered buildings. QUIC was also used to calculate infiltration of the contaminant into the buildings. Indoor concentration levels were found to be much lower than outdoor concentrations because of deposition onto indoor surfaces and particulate capture for buildings with filtration systems. Large differences in indoor concentrations from building to building resulted from differences in leakiness, air handling unit volume exchange rates, and filter type and for naturally ventilated buildings, whether or not the building was sheltered from the prevailing wind by a building immediately upwind.
Analysis of a school building damaged by the 2015 Ranau earthquake Malaysia
NASA Astrophysics Data System (ADS)
Takano, Shugo; Saito, Taiki
2017-10-01
On June 5th, 2015 a severe earthquake with a moment Magnitude of 6.0 occurred in Ranau, Malaysia. Depth of the epicenter is 10 km. Due to the earthquake, many facilities were damaged and 18 people were killed due to rockfalls [1]. Because the British Standard (BS) is adopted as a regulation for built buildings in Malaysia, the seismic force is not considered in the structural design. Therefore, the seismic resistance of Malaysian buildings is unclear. To secure the human life and building safety, it is important to grasp seismic resistance of the building. The objective of this study is to evaluate the seismic resistance of the existing buildings in Malaysia built by the British Standard. A school building that was damaged at the Ranau earthquake is selected as the target building. The building is a four story building and the ground floor is designed to be a parking space for the staff. The structural types are infill masonries where main frame is configured by reinforced concrete columns and beams and brick is installed inside the frame as walls. Analysis is performed using the STERA_3D software that is the software to analyze the seismic performance of buildings developed by one of the authors. Firstly, the natural period of the building is calculated and compared with the result of micro-tremor measurement. Secondly, the nonlinear push-over analysis was conducted to evaluate the horizontal load bearing capacity of the building. Thirdly, the earthquake response analysis was conducted using the time history acceleration data measured at the Ranau earthquake by the seismograph installed at Kota Kinabalu. By comparing the results of earthquake response analysis and the actual damage of the building, the reason that caused damage to the building is clarified.
Bennett, D H; Fisk, W; Apte, M G; Wu, X; Trout, A; Faulkner, D; Sullivan, D
2012-08-01
This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale. © 2012 John Wiley & Sons A/S.
Building energy governance in Shanghai
NASA Astrophysics Data System (ADS)
Kung, YiHsiu Michelle
With Asia's surging economies and urbanization, the region is adding to its built environment at an unprecedented rate, especially those population centers in China and India. With numerous existing buildings, plus a new building boom, construction in these major Asian cities has caused momentous sustainability challenges. This dissertation focuses on China's leading city, Shanghai, to explore and assess its existing commercial building energy policies and practices. Research estimates that Shanghai's commercial buildings might become a key challenge with regard to energy use and CO2 emissions as compared to other major Asian cities. Relevant building energy policy instruments at national and local levels for commercial buildings are reviewed. In addition, two benchmarks are established to further assess building energy policies in Shanghai. The first benchmark is based on the synthesis of relevant criteria and policy instruments as recommended by professional organizations, while the second practical benchmark is drawn from an analysis of three global cities: New York, London and Tokyo. Moreover, two large-scale commercial building sites - Shanghai IKEA and Plaza 66 - are selected for investigation and assessment of their efforts on building energy saving measures. Detailed building energy savings, CO2 reductions, and management cost reductions based on data availability and calculations are presented with the co-benefits approach. The research additionally analyzes different interventions and factors that facilitate or constrain the implementation process of building energy saving measures in each case. Furthermore, a multi-scale analytical framework is employed to investigate relevant stakeholders that shape Shanghai's commercial building energy governance. Research findings and policy recommendations are offered at the close of this dissertation. Findings and policy recommendations are intended to facilitate commercial building energy governance in Shanghai and other rapidly growing second-tier or third-tier cities in China, and to further contribute to the general body of knowledge on Asia's urban building sustainability.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bomberg, Mark; Gibson, Michael; Zhang, Jian
This article highlights the need for an active role for building physics in the development of near-zero energy buildings while analyzing an example of an integrated system for the upgrade of existing buildings. The science called either Building Physics in Europe or Building Science in North America has so far a passive role in explaining observed failures in construction practice. In its new role, it would be integrating modeling and testing to provide predictive capability, so much needed in the development of near-zero energy buildings. The authors attempt to create a compact package, applicable to different climates with small modificationsmore » of some hygrothermal properties of materials. This universal solution is based on a systems approach that is routine for building physics but in contrast to separately conceived sub-systems that are typical for the design of buildings today. One knows that the building structure, energy efficiency, indoor environmental quality, and moisture management all need to be considered to ensure durability of materials and control cost of near-zero energy buildings. These factors must be addressed through contributions of the whole design team. The same approach must be used for the retrofit of buildings. As this integrated design paradigm resulted from demands of sustainable built environment approach, building physics must drop its passive role and improve two critical domains of analysis: (i) linked, real-time hygrothermal and energy models capable of predicting the performance of existing buildings after renovation and (ii) basic methods of indoor environment and moisture management when the exterior of the building cannot be modified.« less
Application of BIM Technology in Building Water Supply and Drainage Design
NASA Astrophysics Data System (ADS)
Wei, Tianyun; Chen, Guiqing; Wang, Junde
2017-12-01
Through the application of BIM technology, the idea of building water supply and drainage designers can be related to the model, the various influencing factors to affect water supply and drainage design can be considered more comprehensively. BIM(Building information model) technology assist in improving the design process of building water supply and drainage, promoting the building water supply and drainage planning, enriching the building water supply and drainage design method, improving the water supply and drainage system design level and building quality. Combined with fuzzy comprehensive evaluation method to analyze the advantages of BIM technology in building water supply and drainage design. Therefore, application prospects of BIM technology are very worthy of promotion.
Sampling design for the 1980 commercial and multifamily residential building survey
NASA Astrophysics Data System (ADS)
Bowen, W. M.; Olsen, A. R.; Nieves, A. L.
1981-06-01
The extent to which new building design practices comply with the proposed 1980 energy budget levels for commercial and multifamily residential building designs (DEB-80) can be assessed by: (1) identifying small number of building types which account for the majority of commercial buildings constructed in the U.S.A.; (2) conducting a separate survey for each building type; and (3) including only buildings designed during 1980. For each building, the design energy consumption (DEC-80) will be determined by the DOE2.1 computer program. The quantity X = (DEC-80 - DEB-80). These X quantities can then be used to compute sample statistics. Inferences about nationwide compliance with DEB-80 may then be made for each building type. Details of the population, sampling frame, stratification, sample size, and implementation of the sampling plan are provided.
Edwards, N
2008-10-01
The international introduction of performance-based building codes calls for a re-examination of indicators used to monitor their implementation. Indicators used in the building sector have a business orientation, target the life cycle of buildings, and guide asset management. In contrast, indicators used in the health sector focus on injury prevention, have a behavioural orientation, lack specificity with respect to features of the built environment, and do not take into account patterns of building use or building longevity. Suggestions for metrics that bridge the building and health sectors are discussed. The need for integrated surveillance systems in health and building sectors is outlined. It is time to reconsider commonly used epidemiological indicators in the field of injury prevention and determine their utility to address the accountability requirements of performance-based codes.
1. Photocopy of undated wash drawing. The largest building is ...
1. Photocopy of undated wash drawing. The largest building is the Hotel Williams. Next to it is the Williams House (Williams Hotel Annex), HABS No. MI-258 A. Below them are the log cabins built by the American Fur Company (from left to right): Log Building No. 1 (MI-258 C), Log Building No. 2 (MI-258 D), Log Building No. 3 (not documented), Log Building No. 4 (MI-258 E), and Log Building No. 5 (MI-258 F). (Williams Log House, MI-258 B, and Log Building No. 8, MI-258 G, are not shown). The drawing is in the collection of the Michigan Historical Commission. Although it does not have a date, it was painted in the early 20th century after the main building was constructed. - Hotel Williams, Murray Bay, Munising, Alger County, MI
NET-ZERO ENERGY BUILDING OPERATOR TRAINING PROGRAM (NZEBOT)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brizendine, Anthony; Byars, Nan; Sleiti, Ahmad
2012-12-31
The primary objective of the Net-Zero Energy Building Operator Training Program (NZEBOT) was to develop certificate level training programs for commercial building owners, managers and operators, principally in the areas of energy / sustainability management. The expected outcome of the project was a multi-faceted mechanism for developing the skill-based competency of building operators, owners, architects/engineers, construction professionals, tenants, brokers and other interested groups in energy efficient building technologies and best practices. The training program draws heavily on DOE supported and developed materials available in the existing literature, as well as existing, modified, and newly developed curricula from the Department ofmore » Engineering Technology & Construction Management (ETCM) at the University of North Carolina at Charlotte (UNC-Charlotte). The project goal is to develop a certificate level training curriculum for commercial energy and sustainability managers and building operators that: 1) Increases the skill-based competency of building professionals in energy efficient building technologies and best practices, and 2) Increases the workforce pool of expertise in energy management and conservation techniques. The curriculum developed in this project can subsequently be used to establish a sustainable energy training program that can contribute to the creation of new “green” job opportunities in North Carolina and throughout the Southeast region, and workforce training that leads to overall reductions in commercial building energy consumption. Three energy training / education programs were developed to achieve the stated goal, namely: 1. Building Energy/Sustainability Management (BESM) Certificate Program for Building Managers and Operators (40 hours); 2. Energy Efficient Building Technologies (EEBT) Certificate Program (16 hours); and 3. Energy Efficent Buildings (EEB) Seminar (4 hours). Training Program 1 incorporates the following topics in the primary five-day Building Energy/Sustainability Management Certificate program in five training modules, namely: 1) Strategic Planning, 2) Sustainability Audits, 3) Information Analysis, 4) Energy Efficiency, and 5) Communication. Training Program 2 addresses the following technical topics in the two-day Building Technologies workshop: 1) Energy Efficient Building Materials, 2) Green Roofing Systems, 3) Energy Efficient Lighting Systems, 4) Alternative Power Systems for Buildings, 5) Innovative Building Systems, and 6) Application of Building Performance Simulation Software. Program 3 is a seminar which provides an overview of elements of programs 1 and 2 in a seminar style presentation designed for the general public to raise overall public awareness of energy and sustainability topics.« less
11. GENERAL VIEW LOOKING NORTHEAST, BUILDING NO. 823, AMMUNITIOM NITRATE ...
11. GENERAL VIEW LOOKING NORTHEAST, BUILDING NO. 823, AMMUNITIOM NITRATE LOADING BUILDING, IN LEFT BACKGROUND. BUILDING NO. 824, TNT SCREENING BUILDING, IN RIGHT BACKGROUND. - Picatinny Arsenal, 800 Area, Complete Rounds-Melt Loading District, State Route 15 near I-80, Dover, Morris County, NJ
51. BF corridor, (example of older building meeting with new ...
51. BF corridor, (example of older building meeting with new building addition) from outside room BF-6, basement level, building 500, looking south - Offutt Air Force Base, Strategic Air Command Headquarters & Command Center, Headquarters Building, 901 SAC Boulevard, Bellevue, Sarpy County, NE
48 CFR 652.237-71 - Identification/Building Pass.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Identification/Building... Identification/Building Pass. As prescribed in 637.110(b), insert the following clause. Identification/Building.... (1) The contractor shall obtain a Department of State building pass for all employees performing...
Exterior building details of Building C, east façade: brick quoins, ...
Exterior building details of Building C, east façade: brick quoins, brick lintels, brick window sills, decorative metal grilles, scored cement finished brick wall; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Exterior building details of Building C, west façade: second floor: ...
Exterior building details of Building C, west façade: second floor: four-over-four windows, arch brick lintels, brick sills, decorative metal grilles; easterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
14 CFR 152.607 - Building design requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Building design requirements. 152.607... (CONTINUED) AIRPORTS AIRPORT AID PROGRAM Energy Conservation in Airport Aid Program § 152.607 Building design... or major building modification project proposed at the airport. The building design, construction...
11. BUILDING NO. 18 (ENGINEERING BUILDING), CENTER, IN RELATION TO ...
11. BUILDING NO. 18 (ENGINEERING BUILDING), CENTER, IN RELATION TO BUILDING NO. 19 (BENDING SHOP AND OVEN) AT FAR LEFT, AND TO THE WET BASIN AT FAR RIGHT. VIEW TO NORTH-NORTHWEST. - United Engineering Company Shipyard, 2900 Main Street, Alameda, Alameda County, CA
SECURITY GATE FOR WEAPONS STORAGE AREA. FROM LEFT TO RIGHT, ...
SECURITY GATE FOR WEAPONS STORAGE AREA. FROM LEFT TO RIGHT, STORAGE BUILDING (BUILDING 3584), CONVENTIONAL MUNITIONS SHOP (BUILDING 3580), AND SECURITY POLICE ENTRY CONTROL BUILDING (BUILDING 3582). VIEW TO SOUTHWEST - Plattsburgh Air Force Base, U.S. Route 9, Plattsburgh, Clinton County, NY
45. BUILDING NO. 462, CHEMISTRY LAB (FORMERLY TRACER LOADING BUILDING), ...
45. BUILDING NO. 462, CHEMISTRY LAB (FORMERLY TRACER LOADING BUILDING), VIEW LOOKING SOUTHEAST AT WEST SIDE. BUILDING NO. 462-B, GENERAL PURPOSE MAGAZINE, AT LEFT. - Picatinny Arsenal, 400 Area, Gun Bag Loading District, State Route 15 near I-80, Dover, Morris County, NJ
6. SITE BUILDING 002 SCANNER BUILDING AT "A" ...
6. SITE BUILDING 002 - SCANNER BUILDING - AT "A" FACE (ON SOUTH SIDE) LOOKING DIRECTLY UP RADAR SYSTEM EMITTER/ANTENNA ARRAY FACE WITH 65MM WIDE ANGLE LENS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
24 CFR 941.203 - Design and construction standards.
Code of Federal Regulations, 2013 CFR
2013-04-01
... national building code, such as Uniform Building Code, Council of American Building Officials Code, or Building Officials Conference of America Code; (2) Applicable State and local laws, codes, ordinances, and... intended to serve. Building design and construction shall strive to encourage in residents a proprietary...
7 CFR 4274.337 - Other regulatory requirements.
Code of Federal Regulations, 2012 CFR
2012-01-01
... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...
7 CFR 4274.337 - Other regulatory requirements.
Code of Federal Regulations, 2013 CFR
2013-01-01
... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...
24 CFR 941.203 - Design and construction standards.
Code of Federal Regulations, 2012 CFR
2012-04-01
... national building code, such as Uniform Building Code, Council of American Building Officials Code, or Building Officials Conference of America Code; (2) Applicable State and local laws, codes, ordinances, and... intended to serve. Building design and construction shall strive to encourage in residents a proprietary...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2013 CFR
2013-07-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
7 CFR 4274.337 - Other regulatory requirements.
Code of Federal Regulations, 2014 CFR
2014-01-01
... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2012 CFR
2012-01-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2014 CFR
2014-01-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
41 CFR 128-1.8005 - Seismic safety standards.
Code of Federal Regulations, 2011 CFR
2011-01-01
... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...
42. CONTEXT VIEW LOOKING WEST OF BUILDING 269 (PAINT BUILDING) ...
42. CONTEXT VIEW LOOKING WEST OF BUILDING 269 (PAINT BUILDING) IN ASSEMBLY AREA SHOWING BUILDING 272 (STORAGE STRUCTURE A-2) IN BACKGROUND. - Loring Air Force Base, Weapons Storage Area, Northeastern corner of base at northern end of Maine Road, Limestone, Aroostook County, ME
Two Decades of Structure Building
Gernsbacher, Morton Ann
2014-01-01
During the past decade I have been developing a very simple framework for describing the cognitive processes and mechanisms involved in discourse comprehension. I call this framework the Structure Building Framework, and it is based on evidence provided during the first decade of discourse processing research. According to the Structure Building Framework, the goal of comprehension is to build coherent mental representations or structures. Comprehenders build each structure by first laying a foundation. Comprehenders develop mental structures by mapping on new information when that information coheres or relates to previous information. However, when the incoming information is less related, comprehenders shift and attach a new substructure. The building blocks of mental structures are memory nodes, which are activated by incoming stimuli and controlled by two cognitive mechanisms: suppression and enhancement. In this article, first I review the seminal work on which the Structure Building Framework is based (the first decade of structure building research); then I recount the research I have conducted to test the Structure Building Framework (the second decade of structure building research). PMID:25484476
Building simulation: Ten challenges
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hong, Tianzhen; Langevin, Jared; Sun, Kaiyu
Buildings consume more than one-third of the world’s primary energy. Reducing energy use and greenhouse-gas emissions in the buildings sector through energy conservation and efficiency improvements constitutes a key strategy for achieving global energy and environmental goals. Building performance simulation has been increasingly used as a tool for designing, operating and retrofitting buildings to save energy and utility costs. However, opportunities remain for researchers, software developers, practitioners and policymakers to maximize the value of building performance simulation in the design and operation of low energy buildings and communities that leverage interdisciplinary approaches to integrate humans, buildings, and the power gridmore » at a large scale. This paper presents ten challenges that highlight some of the most important issues in building performance simulation, covering the full building life cycle and a wide range of modeling scales. In conclusion, the formulation and discussion of each challenge aims to provide insights into the state-of-the-art and future research opportunities for each topic, and to inspire new questions from young researchers in this field.« less
Building simulation: Ten challenges
Hong, Tianzhen; Langevin, Jared; Sun, Kaiyu
2018-04-12
Buildings consume more than one-third of the world’s primary energy. Reducing energy use and greenhouse-gas emissions in the buildings sector through energy conservation and efficiency improvements constitutes a key strategy for achieving global energy and environmental goals. Building performance simulation has been increasingly used as a tool for designing, operating and retrofitting buildings to save energy and utility costs. However, opportunities remain for researchers, software developers, practitioners and policymakers to maximize the value of building performance simulation in the design and operation of low energy buildings and communities that leverage interdisciplinary approaches to integrate humans, buildings, and the power gridmore » at a large scale. This paper presents ten challenges that highlight some of the most important issues in building performance simulation, covering the full building life cycle and a wide range of modeling scales. In conclusion, the formulation and discussion of each challenge aims to provide insights into the state-of-the-art and future research opportunities for each topic, and to inspire new questions from young researchers in this field.« less
Hybrid Model-Based and Data-Driven Fault Detection and Diagnostics for Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank, Stephen; Heaney, Michael; Jin, Xin
Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energymore » models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Frank, Stephen; Heaney, Michael; Jin, Xin
Commercial buildings often experience faults that produce undesirable behavior in building systems. Building faults waste energy, decrease occupants' comfort, and increase operating costs. Automated fault detection and diagnosis (FDD) tools for buildings help building owners discover and identify the root causes of faults in building systems, equipment, and controls. Proper implementation of FDD has the potential to simultaneously improve comfort, reduce energy use, and narrow the gap between actual and optimal building performance. However, conventional rule-based FDD requires expensive instrumentation and valuable engineering labor, which limit deployment opportunities. This paper presents a hybrid, automated FDD approach that combines building energymore » models and statistical learning tools to detect and diagnose faults noninvasively, using minimal sensors, with little customization. We compare and contrast the performance of several hybrid FDD algorithms for a small security building. Our results indicate that the algorithms can detect and diagnose several common faults, but more work is required to reduce false positive rates and improve diagnosis accuracy.« less
Urban Renewable Building And Neighborhood Optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
URBANopt is a user interface for creating and running district and city scale building energy simulations. The framework is built around the OpenStudio Urban Measures which are part of the OpenStudio project. Building footprints, building height, building type, and other data can be imported from public records or other sources. Footprints and locations for new buildings and district systems can also be specified. OpenStudio Measures are used to create starting point energy models and to model energy design features and efficiency measures for each building. URBANopt allows a user to pose several scenarios such as “what if 30% of themore » commercial retail buildings added roof top solar” or “what if all elementary schools converted to ground source heat pumps” and then visualize the impacts at a district or city scale. URBANopt is capable of modeling existing buildings, new construction, and district energy systems. URBANopt can be used to explore options for achieving Zero Energy across a collection of buildings (e.g., Zero Energy Districts).« less
NASA Astrophysics Data System (ADS)
Latief, Yusuf; Berawi, Mohammed Ali; Basten, Van; Budiman, Rachmat; Riswanto
2017-06-01
Building has a big impact on the environmental developments. There are three general motives in building, namely the economy, society, and environment. Total completed building construction in Indonesia increased by 116% during 2009 to 2011. It made the energy consumption increased by 11% within the last three years. In fact, 70% of energy consumption is used for electricity needs on commercial buildings which leads to an increase of greenhouse gas emissions by 25%. Green Building cycle costs is known as highly building upfront cost in Indonesia. The purpose of optimization in this research improves building performance with some of green concept alternatives. Research methodology is mixed method of qualitative and quantitative approaches through questionnaire surveys and case study. Assessing the successful of optimization functions in the existing green building is based on the operational and maintenance phase with the Life Cycle Assessment Method. Choosing optimization results were based on the largest efficiency of building life cycle and the most effective cost to refund.
Building Energy Asset Score for Building Owners
DOE Office of Scientific and Technical Information (OSTI.GOV)
Building Technologies Office
2015-01-01
The Building Energy Asset Score is a national standardized tool for evaluating the physical and structural energy efficiency of commercial and multifamily residential buildings. The Asset Score generates a simple energy efficiency rating that enables comparison among buildings, and identifies opportunities for users to invest in energy efficiency upgrades. It is web-based and free to use. This fact sheet discusses the value of the score for building owners.
Hongmei Gu; Richard Bergman
2018-01-01
AbstractWith the worldâs increasing focus on sustainability in the construction sector through green building systems, the U.S. Department of Agriculture (USDA) has been ac-tively engaged in green building advocacy in the United States through USDA Tall Wood Building competitions and follow-up research on use of mass timber for nonresi-dential buildings. The USDA...
Building Change Detection from LIDAR Point Cloud Data Based on Connected Component Analysis
NASA Astrophysics Data System (ADS)
Awrangjeb, M.; Fraser, C. S.; Lu, G.
2015-08-01
Building data are one of the important data types in a topographic database. Building change detection after a period of time is necessary for many applications, such as identification of informal settlements. Based on the detected changes, the database has to be updated to ensure its usefulness. This paper proposes an improved building detection technique, which is a prerequisite for many building change detection techniques. The improved technique examines the gap between neighbouring buildings in the building mask in order to avoid under segmentation errors. Then, a new building change detection technique from LIDAR point cloud data is proposed. Buildings which are totally new or demolished are directly added to the change detection output. However, for demolished or extended building parts, a connected component analysis algorithm is applied and for each connected component its area, width and height are estimated in order to ascertain if it can be considered as a demolished or new building part. Finally, a graphical user interface (GUI) has been developed to update detected changes to the existing building map. Experimental results show that the improved building detection technique can offer not only higher performance in terms of completeness and correctness, but also a lower number of undersegmentation errors as compared to its original counterpart. The proposed change detection technique produces no omission errors and thus it can be exploited for enhanced automated building information updating within a topographic database. Using the developed GUI, the user can quickly examine each suggested change and indicate his/her decision with a minimum number of mouse clicks.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.
2011-02-01
This best practices guide is the twelfth in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the cold and very cold climates can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. Themore » best practices described in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and thos erequirements are highlighted in the text. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.« less
NASA Astrophysics Data System (ADS)
Poerbo, Heru W.; Martokusumo, Widjaja; Donny Koerniawan, M.; Aulia Ardiani, Nissa; Krisanti, Susan
2017-12-01
The Local Government of Bandung city has stipulated a Green Building regulation through the Peraturan Walikota Number 1023/2016. Signed by the mayor in October 2016, Bandung became the first city in Indonesia that put green building as mandatory requirement in the building permit (IMB) process. Green Building regulation is intended to have more efficient consumption of energy and water, improved indoor air quality, management of liquid and solid waste etc. This objective is attained through various design method in building envelope, ventilation and air conditioning system, lighting, indoor transportation system, and electrical system. To minimize energy consumption of buildings that have large openings, sun shading device is often utilized together with low-E glass panes. For buildings in hot humid tropical climate, this method reduces indoor air temperature and thus requires less energy for air conditioning. Indoor air quality is often done by monitoring the carbon dioxide levels. Application of algae as part of building system façade has recently been introduced as replacement of large glass surface in the building façade. Algae are not yet included in the green building regulation because it is relatively new. The research will investigate, with the help of the modelling process and extensive literature, how effective is the implementation of algae in building façade to reduce energy consumption and improve its indoor air quality. This paper is written based on the design of ITB Innovation Park as an ongoing architectural design-based research how the algae-integrated building façade affects the energy consumption.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shah, Monisha; Burr, Andrew; Schulte, Andrew
2016-08-26
The Better Buildings Energy Data Accelerator (BBEDA) is a unique effort that has supported 22 pairs of local governments and their utility companies to help building owners gain access to their whole-building energy data. Municipal and Utility BBEDA Partners committed to develop streamlined and easy-to-use solutions to provide whole-building energy data, especially for multitenant commercial buildings, by the end of 2015. As a result, building owners would be able to make data-driven decisions about their buildings by utilizing readily available energy consumption data for entire buildings. Traditionally, data access was difficult to implement due to technical barriers and the lackmore » of clear value propositions for the utilities. During the past two years, BBEDA has taken a hands-on approach to overcome these barriers by offering a platform for the partners to discuss their challenges and solutions. Customized support was also provided to Partners building their local strategies. Based on the lessons learned from the partners, BBEDA developed a final toolkit with guiding documents that addressed key barriers and served as a resource for the other cities and utilities attempting to establish whole-building data access, including an exploration of opportunities to apply the whole-building data to various aspects of utility demand-side management (DSM) programs. BBEDA has been a catalyst for market transformation by addressing the upstream (to efficiency implementation) barrier of data access, demonstrated through the success of the BBEDA partners to address policy, engagement, and technical hurdles and arrive at replicable solutions to make data access a standard practice nationwide. As a result of best practices identified by the BBEDA, 18 utilities serving more than 2.6 million commercial customers nationwide will provide whole-building energy data access to building owners by 2017. This historic expansion of data accessibility will increase building energy benchmarking, the first step many building owners take to improve the energy efficiency of their buildings.« less
Body Build Satisfaction and the Congruency of Body Build Perceptions.
ERIC Educational Resources Information Center
Hankins, Norman E.; Bailey, Roger C.
1979-01-01
Females were administered the somatotype rating scale. Satisfied subjects showed greater congruency between their own and wished-for body build, and greater congruency between their own and friend/date body builds, but less congruency between their own body build and the female stereotype. (Author/BEF)
Exterior building details of Building C, south façade: second floor" ...
Exterior building details of Building C, south façade: second floor" four-over-four windows, arch brick lintels, brick sills, decorative metal grilles and tiebacks; northwesterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Exterior building details of Building B, west façade: road level ...
Exterior building details of Building B, west façade: road level four-over-four double-hung painted-wood windows with brick sill and arch brick lintels; easterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
11. VIEW NORTH, SOUTH FRONT OF MAIN OFFICE UNIT (BUILDING ...
11. VIEW NORTH, SOUTH FRONT OF MAIN OFFICE UNIT (BUILDING I, 2); SOUTH AND EAST FRONTS OF SEED STORAGE BUILDING (BUILDING 21); EAST FRONT OF GREENHOUSE #1 (BUILDING 5) - U.S. Plant Introduction Station, 11601 Old Pond Road, Glenn Dale, Prince George's County, MD
1. VIEW EAST, SEED EXTRACTOR BUILDING ON LEFT, IMPLEMENT BUILDING ...
1. VIEW EAST, SEED EXTRACTOR BUILDING ON LEFT, IMPLEMENT BUILDING ON RIGHT. (see also WV-237-5, WV-237-9, WV-237-h-1, WV-237-L-1) - Parsons Nursery, Seed Extractor Building, South side of U.S. Route 219, Parsons, Tucker County, WV
VIEW LOOKING SOUTHWEST AT BUILDING 122 DURING CONSTRUCTION. BUILDING 122, ...
VIEW LOOKING SOUTHWEST AT BUILDING 122 DURING CONSTRUCTION. BUILDING 122, THE EMERGENCY MEDICAL BUILDING, WAS ONE OF THE ORIGINAL STRUCTURES AT THE ROCKY FLATS PLANT. (5/29/52) - Rocky Flats Plant, Emergency Medical Services Facility, Southwest corner of Central & Third Avenues, Golden, Jefferson County, CO
Video: NREL and Buildings Research - Continuum Magazine | NREL
solutions to improve the energy efficiency of both residential and commercial buildings, and to accelerate the integration of clean energy technologies with buildings. NREL's commercial buildings research focuses on providing large institutional and private sector commercial building owners with tools
9. SITE BUILDING 002 SCANNER BUILDING LOOKING AT ...
9. SITE BUILDING 002 - SCANNER BUILDING - LOOKING AT "C" FACE RADAR SYSTEM EMITTER/ANTENNA. VIEW IS LOOKING SOUTH 30° EAST (NOTE: "C" FACE NOT IN USE AT FACILITY). - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
34. SITE BUILDING 002 SCANNER BUILDING ROOM 105 ...
34. SITE BUILDING 002 - SCANNER BUILDING - ROOM 105 - CHILLER ROOM, SHOWING SINGLE COMPRESSOR, LIQUID CHILLERS AND "CHILLED WATER RETURN", COOLING TOWER 'TOWER WATER RETURN" AND 'TOWER WATER SUPPLY" LINES. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2012 CFR
2012-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2013 CFR
2013-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2014 CFR
2014-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
12 CFR 1807.503 - Project completion.
Code of Federal Regulations, 2011 CFR
2011-01-01
... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...
25. SITE BUILDING 002 SCANNER BUILDING OPERATIONS CENTER ...
25. SITE BUILDING 002 - SCANNER BUILDING - OPERATIONS CENTER - MWOC IN OPERATION AT 1930 ZULU TIME, 26 OCTOBER, 1999. MWOC SCREEN ALSO SHOWS RADAR "FACE A" AND "FACE B" ACTIVE STATUS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
The Building Commissioning Handbook.
ERIC Educational Resources Information Center
Heinz, John A.; Casault, Rick
This book discusses building commissioning, which is the process of certifying that a new facility meets the required specifications. As buildings have become more complex, the traditional methods for building start-up and final acceptance have been proven inadequate, and building commissioning has been developed, which often necessitates the use…
29. SITE BUILDING 002 SCANNER BUILDING FLOOR 3A ...
29. SITE BUILDING 002 - SCANNER BUILDING - FLOOR 3A ("A" FACE) AT SYSTEM LAYOUT GRID 17. GENERAL OBLIQUE VIEW OF "A" FACE INTERIOR SHOWING RADAR EMITTER/ANTENNA INTERFACE ELECTRONICS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
10. SITE BUILDING 002 SCANNER BUILDING LOOKING AT ...
10. SITE BUILDING 002 - SCANNER BUILDING - LOOKING AT SOUTHWEST CORNER "B" FACE AND "C" FACE ON WEST AND EVAPORATIVE COOLING TOWER AT NORTH. VIEW IS LOOKING NORTH 45° EAST. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
19. SITE BUILDING 002 SCANNER BUILDING AIR POLICE ...
19. SITE BUILDING 002 - SCANNER BUILDING - AIR POLICE SITE SECURITY OFFICE WITH "SITE PERIMETER STATUS PANEL" AND REAL TIME VIDEO DISPLAY OUTPUT FROM VIDEO CAMERA SYSTEM AT SECURITY FENCE LOCATIONS. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yu, Sha; Evans, Meredydd; Shi, Qing
China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies onmore » building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components. This chapter examines insulation in walls and roofs; efficient windows and doors; heating, air conditioning and controls; and lighting. These markets have seen significant growth because of the strength of the construction sector but also the specific policies that require and promote efficient building components. At the same time, as requirements have become more stringent, there has been fierce competition, and quality has at time suffered, which in turn has created additional challenges. Next we examine existing buildings in chapter four. China has many Soviet-style, inefficient buildings built before stringent requirements for efficiency were more widely enforced. As a result, there are several specific market opportunities related to retrofits. These fall into two or three categories. First, China now has a code for retrofitting residential buildings in the north. Local governments have targets of the number of buildings they must retrofit each year, and they help finance the changes. The requirements focus on insulation, windows, and heat distribution. Second, the Chinese government recently decided to increase the scale of its retrofits of government and state-owned buildings. It hopes to achieve large scale changes through energy service contracts, which creates an opportunity for energy service companies. Third, there is also a small but growing trend to apply energy service contracts to large commercial and residential buildings. This report assesses the impacts of China’s policies on building energy efficiency. By examining the existing literature and interviewing stakeholders from the public, academic, and private sectors, the report seeks to offer an in-depth insights of the opportunities and barriers for major market segments related to building energy efficiency. The report also discusses trends in building energy use, policies promoting building energy efficiency, and energy performance contracting for public building retrofits.« less
24 CFR 880.602 - Replacement reserve.
Code of Federal Regulations, 2012 CFR
2012-04-01
... equivalent to .006 of the cost of total structures, including main buildings, accessory buildings, garages... projects, an amount equivalent to at least .006 of the cost of total structures, including main buildings, accessory buildings, garages and other buildings, or any higher rate as required from time to time by: (A...
24 CFR 880.602 - Replacement reserve.
Code of Federal Regulations, 2010 CFR
2010-04-01
... equivalent to .006 of the cost of total structures, including main buildings, accessory buildings, garages... projects, an amount equivalent to at least .006 of the cost of total structures, including main buildings, accessory buildings, garages and other buildings, or any higher rate as required from time to time by: (A...
24 CFR 880.602 - Replacement reserve.
Code of Federal Regulations, 2014 CFR
2014-04-01
... equivalent to .006 of the cost of total structures, including main buildings, accessory buildings, garages... projects, an amount equivalent to at least .006 of the cost of total structures, including main buildings, accessory buildings, garages and other buildings, or any higher rate as required from time to time by: (A...
24 CFR 880.602 - Replacement reserve.
Code of Federal Regulations, 2013 CFR
2013-04-01
... equivalent to .006 of the cost of total structures, including main buildings, accessory buildings, garages... projects, an amount equivalent to at least .006 of the cost of total structures, including main buildings, accessory buildings, garages and other buildings, or any higher rate as required from time to time by: (A...
24 CFR 880.602 - Replacement reserve.
Code of Federal Regulations, 2011 CFR
2011-04-01
... equivalent to .006 of the cost of total structures, including main buildings, accessory buildings, garages... projects, an amount equivalent to at least .006 of the cost of total structures, including main buildings, accessory buildings, garages and other buildings, or any higher rate as required from time to time by: (A...
URBANopt Advanced Analytics Platform | Buildings | NREL
-use districts, different buildings may peak in energy consumption at different times. In certain cases applications. Districts, Neighborhoods, and Campuses For districts with different building types and mixed-use buildings? How does energy consumption vary depending on different building efficiency scenarios (e.g
Technicians for Intelligent Buildings. Final Report.
ERIC Educational Resources Information Center
Prescott, Carolyn; Thomson, Ron
"Intelligent building" is a term that has been coined in recent years to describe buildings in which computer technology is intensely applied in two areas of building operations: control systems and shared tenant services. This two-part study provides an overview of the intelligent building industry and reports on issues related to the…
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
2. EXTERIOR VIEW OF BUILDING 25B (TEST CHAMBER BUILDING) AND ...
2. EXTERIOR VIEW OF BUILDING 25B (TEST CHAMBER BUILDING) AND WIND TUNNEL, LOOKING NORTHWEST (1991). - Wright-Patterson Air Force Base, Area B, Buildings 25 & 24,10-foot & 20-foot Wind Tunnel Complex, Northeast side of block bounded by K, G, Third, & Fifth Streets, Dayton, Montgomery County, OH
2. Overview of Buildings 2015, 2133 and 2009, with Building ...
2. Overview of Buildings 2015, 2133 and 2009, with Building 1001 (administration building) in background, looking northeast - Naval Air Station Chase Field, Texas State Highway 202, 4.8 miles east of intersection of Texas State Highway 202 & U.S. State Highway 181, Beeville, Bee County, TX
View of southwest elevation of Building No. 42. Foothill Avenue ...
View of southwest elevation of Building No. 42. Foothill Avenue in foreground, seen from yard of Building No. 41, Building No. 44 at rear. Looking northeast - Easter Hill Village, Building No. 42, Northwest corner of Foothill Avenue & South Twenty-eighth Street, Richmond, Contra Costa County, CA
Code of Federal Regulations, 2010 CFR
2010-01-01
... 9 Animals and Animal Products 2 2010-01-01 2010-01-01 false Buildings. 354.220 Section 354.220... CERTIFICATION VOLUNTARY INSPECTION OF RABBITS AND EDIBLE PRODUCTS THEREOF Buildings and Plant Facilities § 354.220 Buildings. The buildings shall be of sound construction and kept in good repair, and shall be of...
24 CFR 576.55 - Building standards.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Building standards. 576.55 Section... Program Requirements § 576.55 Building standards. (a) Any building for which emergency shelter grant... are: (1) 75 percent or more of the replacement cost of the building, that project must meet the...
21 CFR 225.120 - Buildings and grounds.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Buildings and grounds. 225.120 Section 225.120... Buildings and grounds. Buildings used for production of medicated feed shall provide adequate space for... routine maintenance and cleaning of equipment. Buildings and grounds shall be constructed and maintained...
47 CFR 1.1851 - Building accessibility: New construction and alterations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 47 Telecommunication 1 2010-10-01 2010-10-01 false Building accessibility: New construction and... the Federal Communications Commission § 1.1851 Building accessibility: New construction and alterations. Each building or part of a building that is constructed or altered by, on behalf of, or for the...
27 CFR 24.166 - Buildings or rooms.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Buildings or rooms. 24.166... OF THE TREASURY LIQUORS WINE Construction and Equipment § 24.166 Buildings or rooms. All buildings or... afford adequate protection to the revenue. Each building or room will be constructed of substantial...
32 CFR 644.485 - Sale of buildings and other improvements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 32 National Defense 4 2010-07-01 2010-07-01 true Sale of buildings and other improvements. 644.485... PROPERTY REAL ESTATE HANDBOOK Disposal Disposal of Buildings and Other Improvements (without the Related Land) § 644.485 Sale of buildings and other improvements. Buildings and other improvements made...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-21
... Governmentwide Policy; Office of Federal High- Performance Green Buildings; the Green Building Advisory Committee... meeting of the Green Building Advisory Committee Meeting (the Committee). The meeting is open to the..., Office of Federal High-Performance Green Buildings, Office of Governmentwide Policy, General Services...
1. Context view of Building 205, showing hydrogen tanks in ...
1. Context view of Building 205, showing hydrogen tanks in foreground and Building 202 exhaust scrubber stack in background. View looking southwest from top of mound east of Building 205. - Rocket Engine Testing Facility, GRC Building No. 205, NASA Glenn Research Center, Cleveland, Cuyahoga County, OH
Interior building details of Building A, Room A002: plastered painted ...
Interior building details of Building A, Room A-002: plastered painted west brick wall, four light double-hung wood window with brick arch lintel, east plastered wall (could be granite), wood ceiling; northerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Interior building details of Building B, Room B004: south brick ...
Interior building details of Building B, Room B-004: south brick wall partial painted brick plaster with stair scar trace, historic brick infilled arch entry way to Room C-001; southeasterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Library Buildings and Equipment Section. Management and Technology Division. Papers.
ERIC Educational Resources Information Center
International Federation of Library Associations, The Hague (Netherlands).
Papers on library buildings and equipment, which were presented at the 1983 International Federation of Library Associations (IFLA) conference, include: (1) "The Impact of Technology on Library Buildings," in which Rolf Fuhlrott (West Germany) discusses construction technology (types of building materials and library building design),…
23 CFR 710.313 - Design-build projects.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 23 Highways 1 2010-04-01 2010-04-01 false Design-build projects. 710.313 Section 710.313 Highways... REAL ESTATE Project Development § 710.313 Design-build projects. (a) In the case of a design-build...-way acquisition and clearance services may be incorporated into the design-build contract if allowed...
23 CFR 710.313 - Design-build projects.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 23 Highways 1 2011-04-01 2011-04-01 false Design-build projects. 710.313 Section 710.313 Highways... REAL ESTATE Project Development § 710.313 Design-build projects. (a) In the case of a design-build...-way acquisition and clearance services may be incorporated into the design-build contract if allowed...
23 CFR 710.313 - Design-build projects.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 23 Highways 1 2012-04-01 2012-04-01 false Design-build projects. 710.313 Section 710.313 Highways... REAL ESTATE Project Development § 710.313 Design-build projects. (a) In the case of a design-build...-way acquisition and clearance services may be incorporated into the design-build contract if allowed...
42 CFR 52b.12 - What are the minimum requirements of construction and equipment?
Code of Federal Regulations, 2014 CFR
2014-10-01
...-8400). (3) ICBO “Uniform Building Code,” Volumes 1-3 (1997). International Conference of Building...-4406). (4) BOCA National Building Code (1996) 1998 Supplement, Building Officials and Code... Southern Building Code Congress (SBCC), 900 Montclair Road, Birmingham, AL 35213-1206 (telephone 205-591...
42 CFR 52b.12 - What are the minimum requirements of construction and equipment?
Code of Federal Regulations, 2012 CFR
2012-10-01
...-8400). (3) ICBO “Uniform Building Code,” Volumes 1-3 (1997). International Conference of Building...-4406). (4) BOCA National Building Code (1996) 1998 Supplement, Building Officials and Code... Southern Building Code Congress (SBCC), 900 Montclair Road, Birmingham, AL 35213-1206 (telephone 205-591...
42 CFR 52b.12 - What are the minimum requirements of construction and equipment?
Code of Federal Regulations, 2013 CFR
2013-10-01
...-8400). (3) ICBO “Uniform Building Code,” Volumes 1-3 (1997). International Conference of Building...-4406). (4) BOCA National Building Code (1996) 1998 Supplement, Building Officials and Code... Southern Building Code Congress (SBCC), 900 Montclair Road, Birmingham, AL 35213-1206 (telephone 205-591...
10 CFR 434.505 - Reference building method.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-08
... Management Regulation; FMR Bulletin PBS-2011-B1; Redesignations of Federal Buildings AGENCY: Public Buildings... announces the redesignations of three Federal buildings. DATES: Expiration Date: This bulletin announcement expires June 30, 2011. The building redesignations remain in effect until canceled or superseded by...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-02
... Management Regulation; FMR Bulletin PBS-2011-B2; Redesignations of Federal Buildings AGENCY: Public Buildings... announces the designation and redesignation of two Federal buildings. Expiration Date: This bulletin announcement expires January 31, 2012. The building designation and redesignation remains in effect until...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-10
... Management Regulation; FMR Bulletin PBS-2010-B5; Redesignations of Federal Buildings AGENCY: Public Buildings... announces the designation and redesignation of two Federal buildings. DATES: Expiration Date: This bulletin announcement expires April 30, 2011. The building designation and redesignation remains in effect until...
20. SITE BUILDING 002 SCANNER BUILDING IN COMPUTER ...
20. SITE BUILDING 002 - SCANNER BUILDING - IN COMPUTER ROOM LOOKING AT "CONSOLIDATED MAINTENANCE OPERATIONS CENTER" JOB AREA AND OPERATION WORK CENTER. TASKS INCLUDE RADAR MAINTENANCE, COMPUTER MAINTENANCE, CYBER COMPUTER MAINTENANCE AND RELATED ACTIVITIES. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
26 CFR 1.42-6 - Buildings qualifying for carryover allocations.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 26 Internal Revenue 1 2012-04-01 2012-04-01 false Buildings qualifying for carryover allocations... TAX INCOME TAXES Credits Against Tax § 1.42-6 Buildings qualifying for carryover allocations. (a... carryover allocation may only be made with respect to a qualified building. A qualified building is any...
26 CFR 1.42-6 - Buildings qualifying for carryover allocations.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 26 Internal Revenue 1 2013-04-01 2013-04-01 false Buildings qualifying for carryover allocations... TAX INCOME TAXES Credits Against Tax § 1.42-6 Buildings qualifying for carryover allocations. (a... carryover allocation may only be made with respect to a qualified building. A qualified building is any...
Interior building details of Building C, Room C003 and Room ...
Interior building details of Building C, Room C-003 and Room C-002 catwalk above false ceiling, east brick retaining wall, brick north wall, 1930 retrofit pillars, wood floor joints; northeasterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Interior building details of Building C, Room C109: historic single ...
Interior building details of Building C, Room C-109: historic single painted wood closet for Room C-109b and two panel painted wood door for Room C-109a; northerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Exterior building details of Building A; east façade: profiled cement ...
Exterior building details of Building A; east façade: profiled cement plaster door surround, black mesh gate protects a two-light transom atop non-original metal door; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Interior building details of Building B, Room B003: enact eight ...
Interior building details of Building B, Room B-003: enact eight light window over four window light door, six window over double three light window and painted west brick wall; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
1980-05-01
engineering ,ZteNo D R RPTE16 research w 9 laboratory COMPARISON OF BUILDING LOADS ANALYSIS AND SYSTEM THERMODYNAMICS (BLAST) AD 0 5 5,0 3COMPUTER PROGRAM...Building Loads Analysis and System Thermodynamics (BLAST) computer program. A dental clinic and a battalion headquarters and classroom building were...Building and HVAC System Data Computer Simulation Comparison of Actual and Simulated Results ANALYSIS AND FINDINGS
REACTOR SERVICE BUILDING, TRA635, CONTEXTUAL VIEW DURING CONSTRUCTION. CAMERA IS ...
REACTOR SERVICE BUILDING, TRA-635, CONTEXTUAL VIEW DURING CONSTRUCTION. CAMERA IS ATOP MTR BUILDING AND LOOKING SOUTHERLY. FOUNDATION AND DRAINS ARE UNDER CONSTRUCTION. THE BUILDING WILL BUTT AGAINST CHARGING FACE OF PLUG STORAGE BUILDING. HOT CELL BUILDING, TRA-632, IS UNDER CONSTRUCTION AT TOP CENTER OF VIEW. INL NEGATIVE NO. 8518. Unknown Photographer, 8/25/1953 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
2015-12-01
This page intentionally left blank.) ERDC/CERL TR-15-37, Vol. II Fort Eustis, Building 1605 593 FORT EUSTIS...Warehouse Supply & Equipment Base - General Purpose Warehouse - Building 1605 STATUS Usable ARCHITECT/BUILDER Unknown DATE OF CONSTRUCTION 1955 DATE...Building 1605 is located in the 1600 Area with three other similar warehouse/storage buildings (1607, 1608, and 1610). The buildings are located
2. GENERAL VIEW LOOKING WEST AT BUILDINGS NO. 509, NO. ...
2. GENERAL VIEW LOOKING WEST AT BUILDINGS NO. 509, NO. 510, NO. 511 COTTON NITRATION LINE. COTTON STOREHOUSE (BUILDING NO. 509) IS IN BACKGROUND, COTTON PACKER AND DRY HOUSE IN MIDGROUND, NITRATING HOUSE (BUILDING NO. 511) IN FOREGROUND. CONVEYOR CARRIED COTTON FROM BUILDING NO. 510 to BUILDING NO. 511 IN 32 LB. LOTS. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ
Sustainability Base Construction Update
NASA Technical Reports Server (NTRS)
Mewhinney, Michael
2012-01-01
Construction of the new Sustainability Base Collaborative support facility, expected to become the highest performing building in the federal government continues at NASA's Ames Research Center, Moffet Field, Calif. The new building is designed to achieve a platinum rating under the leadership in Energy and Environment Design (LEED) new construction standards for environmentally sustainable construction developed by the U. S. Green Building Council, Washington, D. C. When completed by the end of 2011, the $20.6 million building will feature near zero net energy consumption, use 90 percent less potable water than conventionally build buildings of equivalent size, and will result in reduced building maintenance costs.
Understanding Human Perception of Building Categories in Virtual 3d Cities - a User Study
NASA Astrophysics Data System (ADS)
Tutzauer, P.; Becker, S.; Niese, T.; Deussen, O.; Fritsch, D.
2016-06-01
Virtual 3D cities are becoming increasingly important as a means of visually communicating diverse urban-related information. To get a deeper understanding of a human's cognitive experience of virtual 3D cities, this paper presents a user study on the human ability to perceive building categories (e.g. residential home, office building, building with shops etc.) from geometric 3D building representations. The study reveals various dependencies between geometric properties of the 3D representations and the perceptibility of the building categories. Knowledge about which geometries are relevant, helpful or obstructive for perceiving a specific building category is derived. The importance and usability of such knowledge is demonstrated based on a perception-guided 3D building abstraction process.
Analysis on the restriction factors of the green building scale promotion based on DEMATEL
NASA Astrophysics Data System (ADS)
Wenxia, Hong; Zhenyao, Jiang; Zhao, Yang
2017-03-01
In order to promote the large-scale development of the green building in our country, DEMATEL method was used to classify influence factors of green building development into three parts, including green building market, green technology and macro economy. Through the DEMATEL model, the interaction mechanism of each part was analyzed. The mutual influence degree of each barrier factor that affects the green building promotion was quantitatively analysed and key factors for the development of green building in China were also finally determined. In addition, some implementation strategies of promoting green building scale development in our country were put forward. This research will show important reference value and practical value for making policies of the green building promotion.
Development of building energy asset rating using stock modelling in the USA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Goel, Supriya; Makhmalbaf, Atefe
2016-01-29
The US Building Energy Asset Score helps building stakeholders quickly gain insight into the efficiency of building systems (envelope, electrical and mechanical systems). A robust, easy-to-understand 10-point scoring system was developed to facilitate an unbiased comparison of similar building types across the country. The Asset Score does not rely on a database or specific building baselines to establish a rating. Rather, distributions of energy use intensity (EUI) for various building use types were constructed using Latin hypercube sampling and converted to a series of stepped linear scales to score buildings. A score is calculated based on the modelled source EUImore » after adjusting for climate. A web-based scoring tool, which incorporates an analytical engine and a simulation engine, was developed to standardize energy modelling and reduce implementation cost. This paper discusses the methodology used to perform several hundred thousand building simulation runs and develop the scoring scales.« less
Buildings interoperability landscape - Draft
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hardin, Dave B.; Stephan, Eric G.; Wang, Weimin
2015-02-01
Buildings are an integral part of our nation’s energy economy. The advancement in information and communications technology (ICT) has revolutionized energy management in industrial facilities and large commercial buildings. As ICT costs decrease and capabilities increase, buildings automation and energy management features are transforming the small-medium commercial and residential buildings sectors. A vision of a connected world in which equipment and systems within buildings coordinate with each other to efficiently meet their owners’ and occupants’ needs, and where buildings regularly transact business with other buildings and service providers (such as gas and electric service providers) is emerging. However, while themore » technology to support this collaboration has been demonstrated at various degrees of maturity, the integration frameworks and ecosystems of products that support the ability to easily install, maintain, and evolve building systems and their equipment components are struggling to nurture the fledging business propositions of their proponents.« less
NASA Astrophysics Data System (ADS)
Nawi, Mohd Nasrun Mohd; Baharum, Faizal; Ibrahim, Siti Halipah; Riazi, Salman Riazi Mehdi
2017-10-01
Good management of the building will be able to influence the quality of the buildings that remain long, safe and beautiful without any damage and problems. This research paper aims to explore the issue of maintenance and management that appear in managing the commercial building in Malaysian construction and property industry. The data in this research has been gathered through the reviewing process of secondary data such as journals, proceeding, thesis etc. in the area that related to maintenance and management issue in commercial building. As highlighted by previous study, building a good management can ensure that the facilities available in the building are well and meet the standard. Thus, exposure to the problems and needs in the management of the building would be able to improve the quality of building management systems to be more effective and fulfil the client needs and features.
Creating mold-free buildings: a key to avoiding health effects of indoor molds.
Small, Bruce M
2003-08-01
In view of the high costs of building diagnostics and repair subsequent to water damage--as well as the large medical diagnostic and healthcare costs associated with mold growth in buildings--commitment to a philosophy of proactive preventive maintenance for home, apartment, school, and commercial buildings could result in considerable cost savings and avoidance of major health problems among building occupants. The author identifies common causes of mold growth in buildings and summarizes key building design and construction principles essential for preventing mold contamination indoors. Physicians and healthcare workers must be made aware of conditions within buildings that can give rise to mold growth, and of resulting health problems. Timely advice provided to patients already sensitized by exposure to molds could save these individuals, and their families, from further exposures as a result of inadequate building maintenance or an inappropriate choice of replacement housing.
Terwilliger, Thomas C; Grosse-Kunstleve, Ralf W; Afonine, Pavel V; Moriarty, Nigel W; Zwart, Peter H; Hung, Li Wei; Read, Randy J; Adams, Paul D
2008-01-01
The PHENIX AutoBuild wizard is a highly automated tool for iterative model building, structure refinement and density modification using RESOLVE model building, RESOLVE statistical density modification and phenix.refine structure refinement. Recent advances in the AutoBuild wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model-completion algorithms and automated solvent-molecule picking. Model-completion algorithms in the AutoBuild wizard include loop building, crossovers between chains in different models of a structure and side-chain optimization. The AutoBuild wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 to 3.2 A, resulting in a mean R factor of 0.24 and a mean free R factor of 0.29. The R factor of the final model is dependent on the quality of the starting electron density and is relatively independent of resolution.
Seismic analyses of equipment in 2736-Z complex. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ocoma, E.C.
1995-04-01
This report documents the structural qualification for the existing equipment when subjected to seismic loading in the Plutonium Storage Complex. It replaces in entirety Revision 0 and reconciles the U.S. Department of Energy (DOE) comments on Revision 0. The Complex consists of 2736-Z Building (plutonium storage vault), 2736-ZA Building (vault ventilation equipment building), and 2736-ZB Building (shipping/receiving, repackaging activities). The existing equipment structurally qualified in this report are the metal storage racks for 7 inch and lard cans in room 2 of Building 2736-Z; the cubicles, can holders and pedestals in rooms 1, 3, and 4 of Building 2736-Z; themore » ventilation duct including exhaust fans/motors, emergency diesel generator, and HEPA filter housing in Building 2736-ZA; the repackaging glovebox in Building 2736-ZB; and the interface duct between Buildings 2736-Z and 2736-ZA.« less
Bastianoni, Simone; Galli, Alessandro; Pulselli, Riccardo Maria; Niccolucci, Valentina
2007-11-01
This paper focuses on appropriation of natural capital through construction of buildings. The ecological footprint and the Costanza natural capital concepts are applied. The environmental consequences of human settlement are currently of great concern, and a need is felt to reduce the impact of building on the environment. The embodied energy of building materials and the "land area" required to sustain their production are considered to evaluate the demand on nature of this activity. The ecological footprints of 2 typical Italian buildings are compared. The paper also focuses on how to reduce the natural capital appropriation of building construction by means of environmentally inexpensive materials, renewable energy resources, and optimization of the use of bioproductive land by construction of multistoried buildings. Finally, to allocate an environmental load of buildings, an economic evaluation of natural capital appropriation through building construction is proposed.
Assessment of codes, by-laws and regulations relating to air wells in building design
NASA Astrophysics Data System (ADS)
Fadzil, Sharifah Fairuz Syed; Karamazaman, Nazli
2017-10-01
Codes and by-laws concerning air well design (for buildings and lavatories) in Malaysia has been established in the Malaysian Uniform Building By-Laws UBBL number 40 (1) and (2) since the 1980s. Wells are there to fulfill the ventilation and daylighting requirements. The minimum well area according to building storey height are compared between UBBL and the Singapore's well requirements from the Building Construction Authority BCA. A visual and graphical representation (with schematics building and well diagrams drawn to scale) of the minimum well sizes and dimensions is given. It can be seen that if the minimum requirement of well size is used for buildings above 8 storeys high, a thin well resulted which is not proportionate to the building height. A proposed dimension is graphed and given to be used in the UBBL which translated to graphics (3 dimensional buildings drawn to scale) created a much better well proportion.
Earthquake insurance pricing: a risk-based approach.
Lin, Jeng-Hsiang
2018-04-01
Flat earthquake premiums are 'uniformly' set for a variety of buildings in many countries, neglecting the fact that the risk of damage to buildings by earthquakes is based on a wide range of factors. How these factors influence the insurance premiums is worth being studied further. Proposed herein is a risk-based approach to estimate the earthquake insurance rates of buildings. Examples of application of the approach to buildings located in Taipei city of Taiwan were examined. Then, the earthquake insurance rates for the buildings investigated were calculated and tabulated. To fulfil insurance rating, the buildings were classified into 15 model building types according to their construction materials and building height. Seismic design levels were also considered in insurance rating in response to the effect of seismic zone and construction years of buildings. This paper may be of interest to insurers, actuaries, and private and public sectors of insurance. © 2018 The Author(s). Disasters © Overseas Development Institute, 2018.
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
This appendix summarizes building characteristics used to determine heating and cooling loads for each of the five building types in each of the four regions. For the selected five buildings, the following data are attached: new and existing construction characteristics; new and existing construction thermal resistance; floor plan and elevation; people load schedule; lighting load schedule; appliance load schedule; ventilation schedule; and hot water use schedule. For the five building types (single family, apartment buildings, commercial buildings, office buildings, and schools), data are compiled in 10 appendices. These are Building Characteristics; Alternate Energy Sources and Energy Conservation Techniques Description, Costs,more » Fuel Price Scenarios; Life Cycle Cost Model; Simulation Models; Solar Heating/Cooling System; Condensed Weather; Single and Multi-Family Dwelling Characteristics and Energy Conservation Techniques; Mixed Strategies for Energy Conservation and Alternative Energy Utilization in Buildings. An extensive bibliography is given in the final appendix. (MCW)« less
Computational Process Modeling for Additive Manufacturing
NASA Technical Reports Server (NTRS)
Bagg, Stacey; Zhang, Wei
2014-01-01
Computational Process and Material Modeling of Powder Bed additive manufacturing of IN 718. Optimize material build parameters with reduced time and cost through modeling. Increase understanding of build properties. Increase reliability of builds. Decrease time to adoption of process for critical hardware. Potential to decrease post-build heat treatments. Conduct single-track and coupon builds at various build parameters. Record build parameter information and QM Meltpool data. Refine Applied Optimization powder bed AM process model using data. Report thermal modeling results. Conduct metallography of build samples. Calibrate STK models using metallography findings. Run STK models using AO thermal profiles and report STK modeling results. Validate modeling with additional build. Photodiode Intensity measurements highly linear with power input. Melt Pool Intensity highly correlated to Melt Pool Size. Melt Pool size and intensity increase with power. Applied Optimization will use data to develop powder bed additive manufacturing process model.
NASA Astrophysics Data System (ADS)
Basten, Van; Latief, Yusuf; Berawi, Mohammed Ali; Budiman, Rachmat; Riswanto
2017-03-01
Total completed building construction value in Indonesia increased 116% during 2009 to 2011. That's followed by increasing 11% energy consumption in Indonesia in the last three years with 70% energy met to the electricity needs of commercial building. In addition, a few application of green building concept in Indonesia made the greenhouse gas emissions or CO2 amount increased by 25%. Construction, operation, and maintain of building cost consider relatively high. The evaluation in this research is used to improve the building performance with some of green concept alternatives. The research methodology is conducted by combination of qualitative and quantitative approaches through interview and case study. Assessing the successful of optimization functions in the existing green building is based on the operational and maintenance phase with the Life Cycle Assessment (LCA) Method. The result of optimization that is the largest efficiency and effective of building life cycle.
NASA Astrophysics Data System (ADS)
Skiba, Marta; Rzeszowska, Natalia
2017-09-01
One of the five far-reaching goals of the European Union is climate change and sustainable energy use. The first step in the implementation of this task is to reduce energy demand in buildings to a minimum by 2021, and in the case of public buildings by 2019. This article analyses the possibility of improving energy efficiency in public buildings, the relationship between particular indicators of the demand for usable energy (UE), final energy (FE) and primary energy (PE) in buildings and the impact of these indicators on the assessment of energy efficiency in public buildings, based on 5 variants of extensive thermal renovation of a school building. The analysis of the abovementioned variants confirms that the thermal renovation of merely the outer envelope of the building is insufficient and requires the use of additional energy sources, for example RES. Moreover, each indicator of energy demand in the building plays a key role in assessing the energy efficiency of the building. For this reason it is important to analyze each of them individually, as well as the dependencies between them.
Building Energy Efficiency in Rural China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Evans, Meredydd; Yu, Sha; Song, Bo
2014-04-01
Rural buildings in China now account for more than half of China’s total building energy use. Forty percent of the floorspace in China is in rural villages and towns. Most of these buildings are very energy inefficient, and may struggle to meet basic needs. They are cold in the winter, and often experience indoor air pollution from fuel use. The Chinese government plans to adopt a voluntary building energy code, or design standard, for rural homes. The goal is to build on China’s success with codes in urban areas to improve efficiency and comfort in rural homes. The Chinese governmentmore » recognizes rural buildings represent a major opportunity for improving national building energy efficiency. The challenges of rural China are also greater than those of urban areas in many ways because of the limited local capacity and low income levels. The Chinese government wants to expand on new programs to subsidize energy efficiency improvements in rural homes to build capacity for larger-scale improvement. This article summarizes the trends and status of rural building energy use in China. It then provides an overview of the new rural building design standard, and describes options and issues to move forward with implementation.« less
Seismic Safety Of Simple Masonry Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guadagnuolo, Mariateresa; Faella, Giuseppe
2008-07-08
Several masonry buildings comply with the rules for simple buildings provided by seismic codes. For these buildings explicit safety verifications are not compulsory if specific code rules are fulfilled. In fact it is assumed that their fulfilment ensures a suitable seismic behaviour of buildings and thus adequate safety under earthquakes. Italian and European seismic codes differ in the requirements for simple masonry buildings, mostly concerning the building typology, the building geometry and the acceleration at site. Obviously, a wide percentage of buildings assumed simple by codes should satisfy the numerical safety verification, so that no confusion and uncertainty have tomore » be given rise to designers who must use the codes. This paper aims at evaluating the seismic response of some simple unreinforced masonry buildings that comply with the provisions of the new Italian seismic code. Two-story buildings, having different geometry, are analysed and results from nonlinear static analyses performed by varying the acceleration at site are presented and discussed. Indications on the congruence between code rules and results of numerical analyses performed according to the code itself are supplied and, in this context, the obtained result can provide a contribution for improving the seismic code requirements.« less
NASA Astrophysics Data System (ADS)
Pavlak, Gregory S.
Building energy use is a significant contributing factor to growing worldwide energy demands. In pursuit of a sustainable energy future, commercial building operations must be intelligently integrated with the electric system to increase efficiency and enable renewable generation. Toward this end, a model-based methodology was developed to estimate the capability of commercial buildings to participate in frequency regulation ancillary service markets. This methodology was integrated into a supervisory model predictive controller to optimize building operation in consideration of energy prices, demand charges, and ancillary service revenue. The supervisory control problem was extended to building portfolios to evaluate opportunities for synergistic effect among multiple, centrally-optimized buildings. Simulation studies performed showed that the multi-market optimization was able to determine appropriate opportunities for buildings to provide frequency regulation. Total savings were increased by up to thirteen percentage points, depending on the simulation case. Furthermore, optimizing buildings as a portfolio achieved up to seven additional percentage points of savings, depending on the case. Enhanced energy and cost savings opportunities were observed by taking the novel perspective of optimizing building portfolios in multiple grid markets, motivating future pursuits of advanced control paradigms that enable a more intelligent electric grid.
NASA Astrophysics Data System (ADS)
Yang, S. W.; Ma, J. J.; Wang, J. M.
2018-04-01
As representative vulnerable regions of the city, dense distribution areas of temporary color steel building are a major target for control of fire risks, illegal buildings, environmental supervision, urbanization quality and enhancement for city's image. In the domestic and foreign literature, the related research mainly focuses on fire risks and violation monitoring. However, due to temporary color steel building's special characteristics, the corresponding research about temporal and spatial distribution, and influence on urban spatial form etc. has not been reported. Therefore, firstly, the paper research aim plans to extract information of large-scale color steel building from high-resolution images. Secondly, the color steel plate buildings were classified, and the spatial and temporal distribution and aggregation characteristics of small (temporary buildings) and large (factory building, warehouse, etc.) buildings were studied respectively. Thirdly, the coupling relationship between the spatial distribution of color steel plate and the spatial pattern of urban space was analysed. The results show that there is a good coupling relationship between the color steel plate building and the urban spatial form. Different types of color steel plate building represent the pattern of regional differentiation of urban space and the phased pattern of urban development.
Hasik, Vaclav; Anderson, Naomi E; Collinge, William O; Thiel, Cassandra L; Khanna, Vikas; Wirick, Jason; Piacentini, Richard; Landis, Amy E; Bilec, Melissa M
2017-02-07
Aging water infrastructure and increased water scarcity have resulted in higher interest in water reuse and decentralization. Rating systems for high-performance buildings implicitly promote the use of building-scale, decentralized water supply and treatment technologies. It is important to recognize the potential benefits and trade-offs of decentralized and centralized water systems in the context of high-performance buildings. For this reason and to fill a gap in the current literature, we completed a life cycle assessment (LCA) of the decentralized water system of a high-performance, net-zero energy, net-zero water building (NZB) that received multiple green building certifications and compared the results with two modeled buildings (conventional and water efficient) using centralized water systems. We investigated the NZB's impacts over varying lifetimes, conducted a break-even analysis, and included Monte Carlo uncertainty analysis. The results show that, although the NZB performs better in most categories than the conventional building, the water efficient building generally outperforms the NZB. The lifetime of the NZB, septic tank aeration, and use of solar energy have been found to be important factors in the NZB's impacts. While these findings are specific to the case study building, location, and treatment technologies, the framework for comparison of water and wastewater impacts of various buildings can be applied during building design to aid decision making. As we design and operate high-performance buildings, the potential trade-offs of advanced decentralized water treatment systems should be considered.
NASA Astrophysics Data System (ADS)
Hazli Abdellah, Roy; Asrul Nasid Masrom, Md; Chen, Goh Kai; Mohamed, Sulzakimin; Omar, Roshartini
2017-11-01
The focus on net-zero energy buildings (NZEBs) has been widely analysed and discussed particularly when European Union Parliament are progressively moving towards regulation that promotes the improvement of energy efficiency (EE). Additionally, it also to reduce energy consumption through the recast of the EU Directive on Energy Performance of Buildings (EPBD) in which all new buildings to be “nearly Zero-Energy” Buildings by 2020. Broadly, there is a growing trend to explore the feasibility of net zero energy in healthcare sector as the level energy consumption for healthcare sector is found significantly high. Besides that, healthcare buildings energy consumption also exceeds of many other nondomestic building types, and this shortcoming is still undetermined yet especially for developing countries. This paper aims to review the potential of NZEBs in healthcare buildings by considering its concept in design features. Data are gathered through a comprehensive energy management literature review from previous studies. The review is vital to encourage construction players to increase their awareness, practices, and implementation of NZEBs in healthcare buildings. It suggests that NZEBs concept has a potential to be adapted in healthcare buildings through emphasizing of passive approach as well as the utilization of energy efficiency systems and renewable energy systems in buildings. This paper will provide a basis knowledge for construction key players mainly architects to promote NZEBs concept at design stage for healthcare buildings development.
[Building Process and Architectural Planning Characteristics of Daehan Hospital Main Building].
Lee, Geauchul
2016-04-01
This paper explores the introduction process of Daehan Hospital from Japan as the modern medical facility in Korea, and the architectural planning characteristics as a medical facility through the detailed building process of Daehan Hospital main building. The most noticeable characteristic of Daehan Hospital is that it was designed and constructed not by Korean engineers but by Japanese engineers. Therefore, Daehan Hospital was influenced by Japanese early modern medical facility, and Japanese engineers modeled Daehan Hospital main building on Tokyo Medical School main building which was constructed in 1876 as the first national medical school and hospital. The architectural type of Tokyo Medical School main building was a typical school architecture in early Japanese modern period which had a middle corridor and a pseudo Western-style tower, but Tokyo Medical School main building became the model of a medical facility as the symbol of the medical department in Tokyo Imperial University. This was the introduction and transplantation process of Japanese modern 'model' like as other modern systems and technologies during the Korean modern transition period. However, unlike Tokyo Medical School main building, Daehan Hospital main building was constructed not as a wooden building but as a masonry building. Comparing with the function of Daehan Hospital main building, its architectural form and construction costs was excessive scale, which was because Japanese Resident-General of Korea had the intention of ostentation that Japanese modernity was superior to Korean Empire.
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
Yan, Da; Hong, Tianzhen; Dong, Bing; ...
2017-09-28
Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupantmore » behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.« less
IEA EBC Annex 66: Definition and simulation of occupant behavior in buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yan, Da; Hong, Tianzhen; Dong, Bing
Here, more than 30% of the total primary energy in the world is consumed in buildings. It is crucial to reduce building energy consumption in order to preserve energy resources and mitigate global climate change. Building performance simulations have been widely used for the estimation and optimization of building performance, providing reference values for the assessment of building energy consumption and the effects of energy-saving technologies. Among the various factors influencing building energy consumption, occupant behavior has drawn increasing attention. Occupant behavior includes occupant presence, movement, and interaction with building energy devices and systems. However, there are gaps in occupantmore » behavior modeling as different energy modelers have employed varied data and tools to simulate occupant behavior, therefore producing different and incomparable results. Aiming to address these gaps, the International Energy Agency (IEA) Energy in Buildings and Community (EBC) Programme Annex 66 has established a scientific methodological framework for occupant behavior research, including data collection, behavior model representation, modeling and evaluation approaches, and the integration of behavior modeling tools with building performance simulation programs. Annex 66 also includes case studies and application guidelines to assist in building design, operation, and policymaking, using interdisciplinary approaches to reduce energy use in buildings and improve occupant comfort and productivity. This paper highlights the key research issues, methods, and outcomes pertaining to Annex 66, and offers perspectives on future research needs to integrate occupant behavior with the building life cycle.« less
Building technolgies program. 1994 annual report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selkowitz, S.E.
1995-04-01
The objective of the Building Technologies program is to assist the U.S. building industry in achieving substantial reductions in building sector energy use and associated greenhouse gas emissions while improving comfort, amenity, health, and productivity in the building sector. We have focused our past efforts on two major building systems, windows and lighting, and on the simulation tools needed by researchers and designers to integrate the full range of energy efficiency solutions into achievable, cost-effective design solutions for new and existing buildings. In addition, we are now taking more of an integrated systems and life cycle perspective to create cost-effectivemore » solutions for more energy efficient, comfortable, and productive work and living environments. More than 30% of all energy use in buildings is attributable to two sources: windows and lighting. Together they account for annual consumer energy expenditures of more than $50 billion. Each affects not only energy use by other major building systems, but also comfort and productivity-factors that influence building economics far more than does direct energy consumption alone. Windows play a unique role in the building envelope, physically separating the conditioned space from the world outside without sacrificing vital visual contact. Throughout every space in a building, lighting systems facilitate a variety of tasks associated with a wide range of visual requirements while defining the luminous qualities of the indoor environment. Window and lighting systems are thus essential components of any comprehensive building science program.« less
Exploring the relation between spatial configuration of buildings and remotely sensed temperatures
NASA Astrophysics Data System (ADS)
Myint, S. W.; Zheng, B.; Kaplan, S.; Huang, H.
2013-12-01
While the relationship between fractional cover of buildings and the UHI has been well studied, relationships of how spatial arrangements (e.g., clustered, dispersed) of buildings influence urban warming are not well understood. Since a diversity of spatial patterns can be observed under the same percentage of buildings cover, it is of great interest and importance to investigate the amount of variation in certain urban thermal feature such as surface temperature that is accounted for by the inclusion of spatial arrangement component. The various spatial arrangements of buildings cover can give rise to different urban thermal behaviors that may not be uncovered with the information of buildings fraction only, but can be captured to some extent using spatial analysis. The goal of this study is to examine how spatial arrangements of buildings influence and shape surface temperature in different urban settings. The study area selected is the Las-Vegas metropolitan area in Nevada, located in the Mojave Desert. An object-oriented approach was used to identify buildings using a Geoeye-1 image acquired on October 12, 2011. A spatial autocorrelation technique (i.e., Moran's I) that can measure spatial pattern (clustered, dispersed) was used to determine spatial configuration of buildings. A daytime temperature layer in degree Celsius, generated from Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER) image, was integrated with Moran's I values of building cover and building fractions to achieve the goals set in the study. To avoid uncertainty and properly evaluate if spatial pattern of buildings has an impact on urban warming, the relation between Moran's I values and surface temperatures was observed at different levels according to their fractions (e.g., 0-0.1, 0.5-0.6, 0.9-1). There is a negative correlation exists between spatial pattern of buildings and surface temperatures implying that dispersed building arrangements elevate surface temperatures more severely than clustered buildings. This suggests that more clustered buildings have less impact on the urban heat island (UHI) effect. We conclude that having buildings as clustered as possible can be expected to protect the settlements from increased heat island effects, reduce pollution, and preserve the hydrological systems.
Beyond the buildingcentric approach: A vision for an integrated evaluation of sustainable buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Conte, Emilia, E-mail: conte@poliba.it; Monno, Valeria, E-mail: vmonno@poliba.it
2012-04-15
The available sustainable building evaluation systems have produced a new environmental design paradigm. However, there is an increasing need to overcome the buildingcentric approach of these systems, in order to further exploit their innovate potential for sustainable building practices. The paper takes this challenge by developing a cross-scale evaluation approach focusing on the reliability of sustainable building design solutions for the context in which the building is situated. An integrated building-urban evaluation model is proposed based on the urban matrix, which is a conceptualisation of the built environment as a social-ecological system. The model aims at evaluating the sustainability ofmore » a building considering it as an active entity contributing to the resilience of the urban matrix. Few holistic performance indicators are used for evaluating such contribution, so expressing the building reliability. The discussion on the efficacy of the model shows that it works as a heuristic tool, supporting the acquisition of a better insight into the complexity which characterises the relationships between the building and the built environment sustainability. Shading new lights on the meaning of sustainable buildings, the model can play a positive role in innovating sustainable building design practices, thus complementing current evaluation systems. - Highlights: Black-Right-Pointing-Pointer We model an integrated building-urban evaluation approach. Black-Right-Pointing-Pointer The urban matrix represents the social-ecological functioning of the urban context. Black-Right-Pointing-Pointer We introduce the concept of reliability to evaluate sustainable buildings. Black-Right-Pointing-Pointer Holistic indicators express the building reliability. Black-Right-Pointing-Pointer The evaluation model works as heuristic tool and complements other tools.« less
Demonstration of reduced-order urban scale building energy models
Heidarinejad, Mohammad; Mattise, Nicholas; Dahlhausen, Matthew; ...
2017-09-08
The aim of this study is to demonstrate a developed framework to rapidly create urban scale reduced-order building energy models using a systematic summary of the simplifications required for the representation of building exterior and thermal zones. These urban scale reduced-order models rely on the contribution of influential variables to the internal, external, and system thermal loads. OpenStudio Application Programming Interface (API) serves as a tool to automate the process of model creation and demonstrate the developed framework. The results of this study show that the accuracy of the developed reduced-order building energy models varies only up to 10% withmore » the selection of different thermal zones. In addition, to assess complexity of the developed reduced-order building energy models, this study develops a novel framework to quantify complexity of the building energy models. Consequently, this study empowers the building energy modelers to quantify their building energy model systematically in order to report the model complexity alongside the building energy model accuracy. An exhaustive analysis on four university campuses suggests that the urban neighborhood buildings lend themselves to simplified typical shapes. Specifically, building energy modelers can utilize the developed typical shapes to represent more than 80% of the U.S. buildings documented in the CBECS database. One main benefits of this developed framework is the opportunity for different models including airflow and solar radiation models to share the same exterior representation, allowing a unifying exchange data. Altogether, the results of this study have implications for a large-scale modeling of buildings in support of urban energy consumption analyses or assessment of a large number of alternative solutions in support of retrofit decision-making in the building industry.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.
2011-09-01
This best practices guide is the 15th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the hot-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices describedmore » in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.
2011-09-01
This best practices guide is the 16th in a series of guides for builders produced by PNNL for the U.S. Department of Energy’s Building America program. This guide book is a resource to help builders design and construct homes that are among the most energy-efficient available, while addressing issues such as building durability, indoor air quality, and occupant health, safety, and comfort. With the measures described in this guide, builders in the mixed-humid climate can build homes that have whole-house energy savings of 40% over the Building America benchmark with no added overall costs for consumers. The best practices describedmore » in this document are based on the results of research and demonstration projects conducted by Building America’s research teams. Building America brings together the nation’s leading building scientists with over 300 production builders to develop, test, and apply innovative, energy-efficient construction practices. Building America builders have found they can build homes that meet these aggressive energy-efficiency goals at no net increased costs to the homeowners. Currently, Building America homes achieve energy savings of 40% greater than the Building America benchmark home (a home built to mid-1990s building practices roughly equivalent to the 1993 Model Energy Code). The recommendations in this document meet or exceed the requirements of the 2009 IECC and 2009 IRC and those requirements are highlighted in the text. Requirements of the 2012 IECC and 2012 IRC are also noted in text and tables throughout the guide. This document will be distributed via the DOE Building America website: www.buildingamerica.gov.« less
Wind-Induced Air-Flow Patterns in an Urban Setting: Observations and Numerical Modeling
NASA Astrophysics Data System (ADS)
Sattar, Ahmed M. A.; Elhakeem, Mohamed; Gerges, Bishoy N.; Gharabaghi, Bahram; Gultepe, Ismail
2018-04-01
City planning can have a significant effect on wind flow velocity patterns and thus natural ventilation. Buildings with different heights are roughness elements that can affect the near- and far-field wind flow velocity. This paper aims at investigating the impact of an increase in building height on the nearby velocity fields. A prototype urban setting of buildings with two different heights (25 and 62.5 cm) is built up and placed in a wind tunnel. Wind flow velocity around the buildings is mapped at different heights. Wind tunnel measurements are used to validate a 3D-numerical Reynolds averaged Naviers-Stokes model. The validated model is further used to calculate the wind flow velocity patterns for cases with different building heights. It was found that increasing the height of some buildings in an urban setting can lead to the formation of large horseshoe vortices and eddies around building corners. A separation area is formed at the leeward side of the building, and the recirculation of air behind the building leads to the formation of slow rotation vortices. The opposite effect is observed in the wake (cavity) region of the buildings, where both the cavity length and width are significantly reduced, and this resulted in a pronounced increase in the wind flow velocity. A significant increase in the wind flow velocity in the wake region of tall buildings with a value of up to 30% is observed. The spatially averaged velocities around short buildings also increased by 25% compared to those around buildings with different heights. The increase in the height of some buildings is found to have a positive effect on the wind ventilation at the pedestrian level.
Demonstration of reduced-order urban scale building energy models
DOE Office of Scientific and Technical Information (OSTI.GOV)
Heidarinejad, Mohammad; Mattise, Nicholas; Dahlhausen, Matthew
The aim of this study is to demonstrate a developed framework to rapidly create urban scale reduced-order building energy models using a systematic summary of the simplifications required for the representation of building exterior and thermal zones. These urban scale reduced-order models rely on the contribution of influential variables to the internal, external, and system thermal loads. OpenStudio Application Programming Interface (API) serves as a tool to automate the process of model creation and demonstrate the developed framework. The results of this study show that the accuracy of the developed reduced-order building energy models varies only up to 10% withmore » the selection of different thermal zones. In addition, to assess complexity of the developed reduced-order building energy models, this study develops a novel framework to quantify complexity of the building energy models. Consequently, this study empowers the building energy modelers to quantify their building energy model systematically in order to report the model complexity alongside the building energy model accuracy. An exhaustive analysis on four university campuses suggests that the urban neighborhood buildings lend themselves to simplified typical shapes. Specifically, building energy modelers can utilize the developed typical shapes to represent more than 80% of the U.S. buildings documented in the CBECS database. One main benefits of this developed framework is the opportunity for different models including airflow and solar radiation models to share the same exterior representation, allowing a unifying exchange data. Altogether, the results of this study have implications for a large-scale modeling of buildings in support of urban energy consumption analyses or assessment of a large number of alternative solutions in support of retrofit decision-making in the building industry.« less
Roofer: An Engineered Management System (EMS) for Bituminous Built-Up Roofs
1989-12-01
individual roof projects. Figure 1 shows an example of a filing sequence for a typical recordkceping system. The file should contain a Building Folder ...for each building and a Roof Section Foldcr for each roof section on the building. Building Folder The Building Folder should contain a completed...should also be kept in the building folder , or if they are kept elsewhere, their location should be stated in the folder . Roof Section Folder A Roof
Semantic Image Based Geolocation Given a Map (Author’s Initial Manuscript)
2016-09-01
novel technique for detection and identification of building facades from geo-tagged reference view using the map and geometry of the building facades. We...2D map of the environment, and geometry of building facades. We evaluate our approach for building identification and geo-localization on a new...location recognition and building identification is done by matching the query view to a reference set, followed by estimation of 3D building facades
Building Energy Codes: Policy Overview and Good Practices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cox, Sadie
2016-02-19
Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.
2. VIEW LOOKING NORTHEAST AT BUILDING 444 UNDER CONSTRUCTION. BUILDING ...
2. VIEW LOOKING NORTHEAST AT BUILDING 444 UNDER CONSTRUCTION. BUILDING 444 WAS THE PRIMARY NON-PLUTONIUM MANUFACTURING FACILITY AT THE ROCKY FLATS PLANT. MANUFACTURING PROCESSES COMPLETED IN THIS BUILDING WERE USED TO FABRICATE WEAPONS COMPONENTS AND ASSEMBLIES FOR A VARIETY OF MATERIALS, INCLUDING DEPLETED URANIUM, BERYLLIUM, STAINLESS STEEL, ALUMINUM, AND VANADIUM. (4/25/52) - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO
DOE Office of Scientific and Technical Information (OSTI.GOV)
Erdmann, Christine A.; Apte, Michael G.
Using the US EPA 100 office-building BASE Study dataset, they conducted multivariate logistic regression analyses to quantify the relationship between indoor CO{sub 2} concentrations (dCO{sub 2}) and mucous membrane (MM) and lower respiratory system (LResp) building related symptoms, adjusting for age, sex, smoking status, presence of carpet in workspace, thermal exposure, relative humidity, and a marker for entrained automobile exhaust. In addition, they tested the hypothesis that certain environmentally-mediated health conditions (e.g., allergies and asthma) confer increased susceptibility to building related symptoms within office buildings. Adjusted odds ratios (ORs) for statistically significant, dose-dependent associations (p < 0.05) for dry eyes,more » sore throat, nose/sinus congestion, and wheeze symptoms with 100 ppm increases in dCO{sub 2} ranged from 1.1 to 1.2. These results suggest that increases in the ventilation rates per person among typical office buildings will, on average, reduce the prevalence of several building related symptoms by up to 70%, even when these buildings meet the existing ASHRAE ventilation standards for office buildings. Building occupants with certain environmentally-mediated health conditions are more likely to experience building related symptoms than those without these conditions (statistically significant ORs ranged from 2 to 11).« less
Style grammars for interactive visualization of architecture.
Aliaga, Daniel G; Rosen, Paul A; Bekins, Daniel R
2007-01-01
Interactive visualization of architecture provides a way to quickly visualize existing or novel buildings and structures. Such applications require both fast rendering and an effortless input regimen for creating and changing architecture using high-level editing operations that automatically fill in the necessary details. Procedural modeling and synthesis is a powerful paradigm that yields high data amplification and can be coupled with fast-rendering techniques to quickly generate plausible details of a scene without much or any user interaction. Previously, forward generating procedural methods have been proposed where a procedure is explicitly created to generate particular content. In this paper, we present our work in inverse procedural modeling of buildings and describe how to use an extracted repertoire of building grammars to facilitate the visualization and quick modification of architectural structures and buildings. We demonstrate an interactive application where the user draws simple building blocks and, using our system, can automatically complete the building "in the style of" other buildings using view-dependent texture mapping or nonphotorealistic rendering techniques. Our system supports an arbitrary number of building grammars created from user subdivided building models and captured photographs. Using only edit, copy, and paste metaphors, the entire building styles can be altered and transferred from one building to another in a few operations, enhancing the ability to modify an existing architectural structure or to visualize a novel building in the style of the others.
Building Coverage Ratio at the Eastern Corridor of Jalan Ir. H. Djuanda Bandung
NASA Astrophysics Data System (ADS)
Megayanti, T.; Widaningsih, L.; Minggra, R.; Dewi, N. I. K.
2018-01-01
Historically in the Colonial period, the Corridor of Jalan Ir. H. Juanda or better known as Jalan Dago was designed as a residential area. As the high development of commercial activity along of Bandung City, almost all of buildings in this area are turned its’ function to supported commercial activity. The change is shown in many aspects from the shape of the building and even occur in changing the old building into a new one due to a high intensity of this commercial activity. This paper investigates the use of Building Coverage Ratio regulation related to functional change in the Corridor of Jalan Ir. H. Juanda Bandung. The aim is to what extent the regulations related to Building Coverage area are implemented. This study used a descriptive qualitative method by conducting observation to identify buildings on the Corridor by dividing it into three segments. The results show quantitatively there is a lot of irrelevancies to Building Coverage Ratio regulation which is shown in the second and third segment. Most of the building in the first segment has in compliance with the regulation. However, to build a harmony in characters of City corridor is not only created by Building Coverage Ratio but also others parameters such as the land use, the shape of buildings, façade, and design concept. Thus, it is highly recommended to create a detail regulation regarding those parameters.
Zhang, Pei-Feng; Hu, Yuan-Man; Xiong, Zai-Ping; Liu, Miao
2011-02-01
Based on the 1:10000 aerial photo in 1997 and the three QuickBird images in 2002, 2005, and 2008, and by using Barista software and GIS and RS techniques, the three-dimensional information of the residential community in Tiexi District of Shenyang was extracted, and the variation pattern of the three-dimensional landscape in the district during its reconstruction in 1997-2008 and related affecting factors were analyzed with the indices, ie. road density, greening rate, average building height, building height standard deviation, building coverage rate, floor area rate, building shape coefficient, population density, and per capita GDP. The results showed that in 1997-2008, the building area for industry decreased, that for commerce and other public affairs increased, and the area for residents, education, and medical cares basically remained stable. The building number, building coverage rate, and building shape coefficient decreased, while the floor area rate, average building height, height standard deviation, road density, and greening rate increased. Within the limited space of residential community, the containing capacity of population and economic activity increased, and the environment quality also improved to some extent. The variation degree of average building height increased, but the building energy consumption decreased. Population growth and economic development had positive correlations with floor area rate, road density, and greening rate, but negative correlation with building coverage rate.
Employing ASHRAE Standard 62-1989 in urban building environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1991-01-01
Indoor air quality (IAQ) is a result of a complex relationship between the contamination sources in a building, the ventilation rate, and the dilution of the indoor air contaminant concentrations with outdoor air. This complex relationship is further complicated by outdoor sources used for dilution air and pollution sinks in a building which may modify or remove contaminants. This paper reports that the factors influencing IAQ in a building are: emissions from indoor contamination sources, dilution rate of outdoor ventilation air, quality of the outdoor dilution air, and systems and materials in a building that change the concentrations of contaminants.more » Emissions from contaminant sources in a building are the primary determinant of IAQ. They include building materials, consumer products, cleaners, furnishings, combustion appliances and processes, biological growth from standing water and damp surfaces and building occupants. These factors combined with the emissions from indoor air contamination sources such as synthetic building materials, modern office equipment, and cleaning and biological agents are believed to increase the levels of indoor air contamination. The physiological reactions to these contaminants, coupled with the psychosocial stresses of the modern office environment, and the wide range of human susceptibility to indoor air contaminants led to the classification of acute building sicknesses: sick building syndrome (SBS), building-related illness (BRI), and multiple chemical sensitivity (MCS).« less
Seasonal frost effects on the dynamic behavior of a twenty-story office building
Yang, Z.; Dutta, U.; Xiong, F.; Biswas, N.; Benz, H.
2008-01-01
Studies have shown that seasonal frost can significantly affect the seismic behavior of a bridge foundation system in cold regions. However, little information could be found regarding seasonal frost effects on the dynamic behavior of buildings. Based on the analysis of building vibration data recorded by a permanent strong-motion instrumentation system, the objective of this paper is to show that seasonal frost can impact the building dynamic behavior and the magnitude of impact may be different for different structures. Ambient noise and seismic data recorded on a twenty-story steel-frame building have been analyzed to examine the building dynamic characteristics in relationship to the seasonal frost and other variables including ground shaking intensity. Subsequently, Finite Element modeling of the foundation-soil system and the building superstructure was conducted to verify the seasonal frost effects. The Finite Element modeling was later extended to a reinforced-concrete (RC) type building assumed to exist at a similar site as the steel-frame building. Results show that the seasonal frost has great impact on the foundation stiffness in the horizontal direction and a clear influence on the building dynamic behavior. If other conditions remain the same, the effects of seasonal frost on structural dynamic behavior may be much more prominent for RC-type buildings than for steel-frame buildings. ?? 2007 Elsevier B.V. All rights reserved.
The Building Blocks of Geology.
ERIC Educational Resources Information Center
Gibson, Betty O.
2001-01-01
Discusses teaching techniques for teaching about rocks, minerals, and the differences between them. Presents a model-building activity that uses plastic building blocks to build crystal and rock models. (YDS)
the energy efficiency of both residential and commercial buildings, and to accelerate the integration Commercial Buildings team focuses on providing large institutional and private sector commercial building
GENERAL PERSPECTIVE VIEW OF THE EAST SIDE OF THE COMPLEX, ...
GENERAL PERSPECTIVE VIEW OF THE EAST SIDE OF THE COMPLEX, VIEW LOOKING SOUTH WITH THE FIRE CACHE BUILDING, COMMUNICATIONS BUILDING, GRAPHICS BUILDING, FOREST PRACTICES BUILDING, AND THE K.O.G. (KEEP OREGON GREEN) BUILDING VISIBLE FROM LEFT TO RIGHT. - Oregon State Forester's Office Complex, 2600 State Street, Salem, Marion, OR
Energy Efficient Building Management | Climate Neutral Research Campuses |
NREL Efficient Building Management Energy Efficient Building Management As campuses complete generate the greatest climate impact. Energy efficient management in the existing stock of buildings is the following links go to sections that describe how an energy buildings management and maintenance program may
VIEW OF BUILDING 778 LOOKING WESTSOUTHWEST. BUILDING 778 HOUSED LAUNDRY ...
VIEW OF BUILDING 778 LOOKING WEST-SOUTHWEST. BUILDING 778 HOUSED LAUNDRY FACILITIES, SHOWERS, LOCKER ROOMS, SANITARY FACILITIES, AN ELECTRIC SHOP, MACHINE SHOP, SHEET METAL SHOP, AND INERT GAS STORAGE. (12/7/90) - Rocky Flats Plant, Laundry Facility, Northeast quad of Plant between buildings 776/777 & 707, Golden, Jefferson County, CO
SOLAR EFFECTS ON BUILDING DESIGN.
ERIC Educational Resources Information Center
Building Research Inst., Inc., Washington, DC.
A REPORT OF A PROGRAM HELD AS PART OF THE BUILDING RESEARCH INSTITUTE 1962 SPRING CONFERENCE ON THE SOLAR EFFECTS ON BUILDING DESIGN. TOPICS DISCUSSED ARE--(1) SOLAR ENERGY DATA APPLICABLE TO BUILDING DESIGN, (2) THERMAL EFFECTS OF SOLAR RADIATION ON MAN, (3) SOLAR EFFECTS ON ARCHITECTURE, (4) SOLAR EFFECTS ON BUILDING COSTS, (5) SELECTION OF…
Interior building details of Building D, Room DM5: mezzanine hallway, ...
Interior building details of Building D, Room D-M5: mezzanine hallway, intact historic asphalt surface flooring, full height partition wall with hoppers and east brick retaining wall with voids from the original veiling joist; southerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
46 CFR 67.99 - Evidence of build.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Evidence of build. 67.99 Section 67.99 Shipping COAST... DOCUMENTATION OF VESSELS Build Requirements for Vessel Documentation § 67.99 Evidence of build. (a) Evidence of the facts of build may be either a completed original form CG-1261, or other original document...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-26
... Buildings Service; Information Collection; GSA Form 3453, Application/Permit for Use of Space in Public Buildings and Grounds AGENCY: Public Buildings Service, GSA. ACTION: Notice of request for comments... regarding GSA Form 3453, Application/Permit for Use of Space in Public Buildings and Grounds. Public...
188. BUILDING 7 (ADMINISTRATION BUILDING), 194041. ALBERT KAHN, INC., ARCHITECTS. ...
188. BUILDING 7 (ADMINISTRATION BUILDING), 1940-41. ALBERT KAHN, INC., ARCHITECTS. GENERAL VIEW FROM EAST SHOWING SOUTH (REAR) ELEVATION AND EAST END WITH STEPPED ENTRANCE CANOPY (AN ADDITION). A PORTION OF BUILDING 8 (HOSPITAL) VISIBLE IN THE BACKGROUND ON RIGHT. - Quonset Point Naval Air Station, Roger Williams Way, North Kingstown, Washington County, RI
Exterior building details of Building C, east façade: historic fouroverfour ...
Exterior building details of Building C, east façade: historic four-over-four window, brick lintel, brick quoins, corbelled brick cornice, spiral metal staircase to inclined stairs rising to second floor cantilever wooden walkway; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Exterior building details of Building A; west façade: exposed common ...
Exterior building details of Building A; west façade: exposed common bond brick wall, arched brick lintels over a two single-light casement window with brick sills, arched brick lintel over door cornice; easterly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
26. SITE BUILDING 002 SCANNER BUILDING OPERATIONS CENTER ...
26. SITE BUILDING 002 - SCANNER BUILDING - OPERATIONS CENTER - MWOC IN OPERATION AT 1945 ZULU TIME, 26 OCTOBER, 1999. "SPACE TRACK BOARD" DATA SHOWING ITEMS #16609 MIR (RUSSIA) AND #25544 ISS (INTERNATIONAL SPACE STATION) BEING TRACKED. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
6. A VIEW TOWARD THE EAST SIDE OF BUILDING NO. ...
6. A VIEW TOWARD THE EAST SIDE OF BUILDING NO. 1, SHOWING THE OFFICE SECTION AT THE SOUTHEAST CORNER. BUILDING NO. 18 (ENGINEERING BUILDING) IS VISIBLE IN THE CENTER DISTANCE, AND BUILDING NO. 12 (OFFICE/SUBSTATION) AT THE RIGHT. - United Engineering Company Shipyard, 2900 Main Street, Alameda, Alameda County, CA
VIEW LOOKING EAST, SA WETSIDE (DISTILLATION BUILDING) ON THE RIGHT, ...
VIEW LOOKING EAST, SA WETSIDE (DISTILLATION BUILDING) ON THE RIGHT, STD (SODA TOWER DRYERS?), SA DRYSIDE ON RIGHT. BEHIND STD BUILDING IS SHD BUILDING (SODA HORIZONTAL DRYERS?) THE ENTIRE DRYING COMPLEX WAS KNOWN AS THE DRYSIDE. - Solvay Process Company, SA Wetside Building, Between Willis & Milton Avenue, Solvay, Onondaga County, NY
ERIC Educational Resources Information Center
Cacciamani, Stefano; Cesareni, Donatella; Martini, Francesca; Ferrini, Tiziana; Fujita, Nobuko
2012-01-01
Understanding how to foster knowledge building in online and blended learning environments is a key for computer-supported collaborative learning research. Knowledge building is a deeply constructivist pedagogy and kind of inquiry learning focused on theory building. A strong indicator of engagement in knowledge building activity is the…
Toward a General Research Process for Using Dubin's Theory Building Model
ERIC Educational Resources Information Center
Holton, Elwood F.; Lowe, Janis S.
2007-01-01
Dubin developed a widely used methodology for theory building, which describes the components of the theory building process. Unfortunately, he does not define a research process for implementing his theory building model. This article proposes a seven-step general research process for implementing Dubin's theory building model. An example of a…
Service building no. 620. Details of ramps in south end ...
Service building no. 620. Details of ramps in south end of service building (Dry Dock Associates, November 7, 1941). In files of Cushman & Wakefiled, building no. 501, Philadelphia Naval Business Center. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Service Building, Dry Docks No. 4 & 5, League Island, Philadelphia, Philadelphia County, PA
Service building no. 620. Details of of Toilet & Wash ...
Service building no. 620. Details of of Toilet & Wash rooms at South end of building (Dry Dock Associates, June 12, 1941). In files of Cushman & Wakefield, building no. 501, Philadephia Naval Business Center. - Naval Base Philadelphia-Philadelphia Naval Shipyard, Service Building, Dry Docks No. 4 & 5, League Island, Philadelphia, Philadelphia County, PA
21. SITE BUILDING 002 SCANNER BUILDING LOOKING AT ...
21. SITE BUILDING 002 - SCANNER BUILDING - LOOKING AT DISC STORAGE SYSTEMS A AND B (A OR B ARE REDUNDANT SYSTEMS), ONE MAINFRAME COMPUTER ON LINE, ONE ON STANDBY WITH STORAGE TAPE, ONE ON STANDBY WITHOUT TAPE INSTALLED. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-28
... Management Regulation; FMR Bulletin PBS-2010-B4; Redesignation of Federal Building AGENCY: Public Buildings... announces the redesignation of a Federal building. DATES: Expiration Date: This bulletin expires December 31, 2010. However, the building redesignation announced by this bulletin will remain in effect until...
26. BUILDING NO. 271I, LEAD AZIDE PRIMER BUILDING, WESTERN CORNER ...
26. BUILDING NO. 271-I, LEAD AZIDE PRIMER BUILDING, WESTERN CORNER OF BUILDING SHOWING DOORS TO MIXING ROOM NO. 4. HAND CRANK VISIBLE AT RIGHT ROTATED SMALL POTS (CONTAINING LEAD AZIDE) IN MIXING ROOMS. - Picatinny Arsenal, 200 Area, Shell Component Loading, State Route 15 near I-80, Dover, Morris County, NJ
1. VIEW LOOKING NORTHWEST AT BUILDING 444 UNDER CONSTRUCTION. ORIGINALLY ...
1. VIEW LOOKING NORTHWEST AT BUILDING 444 UNDER CONSTRUCTION. ORIGINALLY CALLED PLANT A, BUILDING 444 WAS ONE OF THE FIRST BUILDINGS CONSTRUCTED AT THE ROCKY FLATS PLANT. (4/15/52) - Rocky Flats Plant, Non-Nuclear Production Facility, South of Cottonwood Avenue, west of Seventh Avenue & east of Building 460, Golden, Jefferson County, CO
SUNREL Applications | Buildings | NREL
used by the building design team for energy analysis. Zion National Park Visitor's Center Grand Canyon National Park Bookstore NREL Thermal Test Facility NREL Wind Site Entrance Building DPD Office Building Performance Analysis of a High-Mass Residential Building Van Geet residence The Van Geet Off-Grid Home: An
26 CFR 1.42-6 - Buildings qualifying for carryover allocations.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 26 Internal Revenue 1 2011-04-01 2009-04-01 true Buildings qualifying for carryover allocations. 1... INCOME TAXES Credits Against Tax § 1.42-6 Buildings qualifying for carryover allocations. (a) Carryover... carryover allocation may only be made with respect to a qualified building. A qualified building is any...
26 CFR 1.42-6 - Buildings qualifying for carryover allocations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 26 Internal Revenue 1 2010-04-01 2010-04-01 true Buildings qualifying for carryover allocations. 1... INCOME TAXES Credits Against Tax § 1.42-6 Buildings qualifying for carryover allocations. (a) Carryover... carryover allocation may only be made with respect to a qualified building. A qualified building is any...
26 CFR 1.42-6 - Buildings qualifying for carryover allocations.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 26 Internal Revenue 1 2014-04-01 2013-04-01 true Buildings qualifying for carryover allocations. 1... INCOME TAXES Credits Against Tax § 1.42-6 Buildings qualifying for carryover allocations. (a) Carryover... carryover allocation may only be made with respect to a qualified building. A qualified building is any...
This photograph, taken from the main roof of E Building, ...
This photograph, taken from the main roof of E Building, looking north, shows two metal penthouses at right, a similar brick structure and some of the vents and other mechanical devices of the building - Department of Energy, Mound Facility, Electronics Laboratory Building (E Building), One Mound Road, Miamisburg, Montgomery County, OH
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-07-01
The module outlines the regulatory history and purpose of containment buildings. It disucsses the relationship between LDR and containment buildings. It summarizes the design and operating standard applicable to containment buildings and describes the relationship between generator accumulation standards and containment buildings.
Exterior, looking west, Equipment Building to left, Tower at center, ...
Exterior, looking west, Equipment Building to left, Tower at center, Civil Engineering Storage Building (Building 5765) at left - Beale Air Force Base, Perimeter Acquisition Vehicle Entry Phased-Array Warning System, Microwave Equipment Building, End of Spencer Paul Road, north of Warren Shingle Road (14th Street), Marysville, Yuba County, CA
Data on European non-residential buildings.
D'Agostino, Delia; Cuniberti, Barbara; Bertoldi, Paolo
2017-10-01
This data article relates to the research paper Energy consumption and efficiency technology measures in European non-residential buildings (D'Agostino et al., 2017) [1]. The reported data have been collected in the framework of the Green Building Programme that ran from 2006 to 2014. The project has encouraged the adoption of efficiency measures to boost energy savings in European non-residential buildings. Data focus on the one-thousand buildings that joined the Programme allowing to save around 985 GWh/year. The main requirement to join the Programme was the reduction of at least 25% primary energy consumption in a new or retrofitted building. Energy consumption before and after the renovation are provided for retrofitted buildings while, in new constructions, a building had to be designed using at least 25% less energy than requested by the country's building codes. The following data are linked within this article: energy consumption, absolute and relative savings related to primary energy, saving percentages, implemented efficiency measures and renewables. Further information is given about each building in relation to geometry, envelope, materials, lighting and systems.
Sun, Xiaojing; Brown, Marilyn A.; Cox, Matt; ...
2015-03-11
This paper provides a global overview of the design, implementation, and evolution of building energy codes. Reflecting alternative policy goals, building energy codes differ significantly across the United States, the European Union, and China. This review uncovers numerous innovative practices including greenhouse gas emissions caps per square meter of building space, energy performance certificates with retrofit recommendations, and inclusion of renewable energy to achieve “nearly zero-energy buildings”. These innovations motivated an assessment of an aggressive commercial building code applied to all US states, requiring both new construction and buildings with major modifications to comply with the latest version of themore » ASHRAE 90.1 Standards. Using the National Energy Modeling System (NEMS), we estimate that by 2035, such building codes in the United States could reduce energy for space heating, cooling, water heating and lighting in commercial buildings by 16%, 15%, 20% and 5%, respectively. Impacts on different fuels and building types, energy rates and bills as well as pollution emission reductions are also examined.« less
Bi, Xiaoli; Wang, Hui; Ge, Jianping
2010-05-01
Roads and buildings are considered as primary causes of rural landscape changes. In this study, linear regression models were used to analyze the dynamic influences of environmental factors and variables on roads and rural buildings from 1979 to 2005 in Dongzhi Yuan (tableland) of the Loess Plateau, China. The relationship between roads and rural buildings and their effects on Dongzhi Yuan are discussed also. The results showed that three environmental factors (topography, land cover, and development level) explained roads better than rural buildings referring densities and patterns. The environmental variables significantly related to roads have decreased, whereas those related to rural buildings have increased over time. Among these significant variables, percent of farmland mostly determined the densities and patterns of both roads and rural buildings. There was significant correlation between roads and rural buildings in terms of density and pattern. In addition, roads and rural buildings have increased greatly in gully areas of this region. Therefore, more attention should be paid to planning of roads and rural buildings in Dongzhi Yuan.
Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Na; Gorrissen, Willy J.
2013-01-11
The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings inmore » a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.« less
U.S. Team Green Building Challenge 2002
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2002-09-01
Flier about the U.S. Team and its projects participating in the International Green Building Challenge. Along with many other countries, the United States accepted the Green Building Challenge (GBC), an international effort to evaluate and improve the performance of buildings worldwide. GBC started out in 1996 as a competition to determine which country had the greenest buildings; it evolved into a cooperative process among the countries to measure the performance of green buildings. Although the auto industry can easily measure efficiency in terms of miles per gallon, the buildings industry has no standard way to quantify energy and environmental performance.more » The Green Building Challenge participants hope that better tools for measuring the energy and environmental performance of buildings will be an outcome of their efforts and that these tools will lead to higher and better performance levels in buildings around the world. The ultimate goal is to design, construct, and operate buildings that contribute to global sustainability by conserving and/or regenerating natural resources and minimizing nonrenewable energy use. The United States' Green Building Challenge Team '02 selected five buildings from around the country to serve as case studies; each of the five U.S. building designs (as well as all international case studies) were assessed using an in-depth evaluation tool, called the Green Building Assessment Tool (GBTool). The GBTool was specifically created and refined by international teams, for the GBC efforts. The goal of this collaborative effort is to improve this evaluation software tool so that it can be used globally, while taking into account regional and national conditions. The GBTool was used by the U.S. Team to assess and evaluate the energy and environmental performance of these five buildings: (1) Retail (in operation): BigHorn Home Improvement Center, Silverthorne, Colorado; (2) Office (in operation), Philip Merrill Environmental; (3) School (in construction), Clearview Elementary School, Hanover, Pennsylvania; (4) Multi-family residential (in construction), Twenty River Terrace, Battery Park City, New York; and (5) Office/lab (in design), National Oceanic Atmospheric Administration, Honolulu, Hawaii. These projects were selected, not only because they were good examples of high-performance buildings and had interested owners/design team members, but also because building data was available as inputs to test the software tool. Both the tool and the process have been repeatedly refined and enhanced since the first Green Building Challenge event in 1998; participating countries are continuously providing feedback to further improve the tool and global process for the greatest positive effect.« less
Performance of Buildings in the 2009 Western Sumatra Earthquake
NASA Astrophysics Data System (ADS)
Deierlein, G.; Hart, T.; Alexander, N.; Hausler, E.; Henderson, S.; Wood, K.; Cedillos, V.; Wijanto, S.; Cabrera, C.; Rudianto, S.
2009-12-01
The M7.6 earthquake of 30 September 2009 in Western Sumatra, Indonesia caused significant damage and collapse to hundreds of buildings and the deaths of 1,117 people. In Padang City, with a population of about 900,000 people, building collapse was the primary cause of deaths and serious injuries (313 deaths and 431 serious injuries). The predominant building construction types in Padang are concrete moment frames with brick infill and masonry bearing wall systems. Concrete frames are common in multistory commercial retail buildings, offices, schools, and hotels; and masonry bearing wall systems are primarily used in low-rise (usually single story) residential and school buildings. In general, buildings that collapsed did not conform to modern seismic engineering practices that are required by the current Indonesian building code and would be expected in regions of moderate to high seismicity. While collapse of multi-story concrete buildings was more prevalent in older buildings (more than 10 years old), there were several newer buildings that collapsed. Primary deficiencies identified in collapsed or severely damaged buildings included: (a) soft or weak stories that failed in either by sidesway mechanisms or shear failures followed by loss of axial capacity of columns, (b) lack of ductile reinforcing bar detailing in concrete beams, columns, and beam-column joints, (c) poor quality concrete and mortar materials and workmanship, (d) vulnerable building configurations and designs with incomplete or deficient load paths, and (e) out-of-plane wall failures in unreinforced (or marginally reinforced) masonry. While these deficiencies may be expected in older buildings, damage and collapse to some modern (or recently rennovated buildings) indicates a lack of enforcement of building code provisions for design and construction quality assurance. Many new buildings whose structural systems were undamaged were closed due to extensive earthquake damage to brick infill walls, glass facades, ceiling systems and other architectural finishes. These demonstrated the importance of considering deformation compatibility and seismic considerations in the design and detail of architectural elements and non-structural components. Another important lesson learned from this earthquake is the critical role that buildings serve for vertical evacuation (refuge) from tsunami inundation in Padang and similar coastal cities in regions of high tsunami hazards. Severe traffic congestion immediately after the September 30 earthquake demonstrated that horizontal evacuation alone is insufficient to safely evacuate Padang City residents to high ground. Therefore, efforts must be stepped up to pre-screen, assess, and engineer buildings tha can be utilized for vertical evacuation.
National Tribal Building Codes Summit
National Tribal Building Codes summit statement developed to support tribes interested in adopting green and culturally-appropriate building systems to ensure safe, sustainable, affordable, and culturally-appropriate buildings on tribal lands.
Drinking Water Quality in Hospitals and Other Buildings ...
Drinking water quality entering large buildings is generally adequately controlled by the water utility, but localized problems may occur within building or “premise” plumbing. Particular concerns are loss of disinfectant residual and temperature variability, which may enhance pathogen activity and metallic corrosion. Disinfection systems are available to building managers and are being installed in a variety of commercial buildings (hospitals, hotels, office buildings.) Yet our understanding of such additional treatment and of how to monitor end water quality at these buildings is limited. This class lecture will discuss challenges in maintaining acceptable water quality in hospitals, schools and other buildings. To give a lecture to a class of graduate students (ENVE 6054: Physical/Chemical Processes for Water Quality Control) at the University of Cincinnati, by presenting past research projects.
Applying science and mathematics to big data for smarter buildings.
Lee, Young M; An, Lianjun; Liu, Fei; Horesh, Raya; Chae, Young Tae; Zhang, Rui
2013-08-01
Many buildings are now collecting a large amount of data on operations, energy consumption, and activities through systems such as a building management system (BMS), sensors, and meters (e.g., submeters and smart meters). However, the majority of data are not utilized and are thrown away. Science and mathematics can play an important role in utilizing these big data and accurately assessing how energy is consumed in buildings and what can be done to save energy, make buildings energy efficient, and reduce greenhouse gas (GHG) emissions. This paper discusses an analytical tool that has been developed to assist building owners, facility managers, operators, and tenants of buildings in assessing, benchmarking, diagnosing, tracking, forecasting, and simulating energy consumption in building portfolios. © 2013 New York Academy of Sciences.
Energy savings and cost-benefit analysis of the new commercial building standard in China
Zhao, Shanguo; Feng, Wei; Zhang, Shicong; ...
2015-10-07
In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less
Energy savings and cost-benefit analysis of the new commercial building standard in China
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhao, Shanguo; Feng, Wei; Zhang, Shicong
In this study, a comprehensive comparison of the commercial building energy efficiency standard between the previous 2005 version and the new proposed version is conducted, including the energy efficiency analysis and cost-benefit analysis. To better understand the tech-economic performance of the new Chinese standard, energy models were set up based on a typical commercial office building in Chinese climate zones. The building energy standard in 2005 is used as the baseline for this analysis. Key building technologies measures are analyzed individually, including roof, wall, window, lighting and chiller and so on and finally whole building cost-benefit analysis was conducted. Resultsmore » show that the new commercial building energy standard demonstrates good cost-effective performance, with whole building payback period around 4 years.« less
Building Extraction Based on Openstreetmap Tags and Very High Spatial Resolution Image in Urban Area
NASA Astrophysics Data System (ADS)
Kang, L.; Wang, Q.; Yan, H. W.
2018-04-01
How to derive contour of buildings from VHR images is the essential problem for automatic building extraction in urban area. To solve this problem, OSM data is introduced to offer vector contour information of buildings which is hard to get from VHR images. First, we import OSM data into database. The line string data of OSM with tags of building, amenity, office etc. are selected and combined into completed contours; Second, the accuracy of contours of buildings is confirmed by comparing with the real buildings in Google Earth; Third, maximum likelihood classification is conducted with the confirmed building contours, and the result demonstrates that the proposed approach is effective and accurate. The approach offers a new way for automatic interpretation of VHR images.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stovall, Therese K; Biswas, Kaushik; Song, Bo
In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications inmore » green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy efficiency and fire safety. A related issue is the degree to which new standards are adopted and enforced. In the U.S., standards are developed using a consensus process, and local government agencies are free to implement these standards or to ignore them. For example, some U.S. states are still using 2003 versions of the building efficiency standards. There is also a great variation in the degree to which the locally adopted standards are enforced in different U.S. cities and states. With a more central process in China, these issues are different, but possible impacts of variable enforcement efficacy may also exist. Therefore, current building codes in China will be compared to the current state of building fire-safety and energy-efficiency codes in the U.S. and areas for possible improvements in both countries will be explored. In particular, the focus of the applications in China will be on green buildings. The terminology of 'green buildings' has different meanings to different audiences. The U.S. research is interested in both new, green buildings, and on retrofitting existing inefficient buildings. An initial effort will be made to clarify the scope of the pertinent wall insulation systems for these applications.« less
A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery.
Siddiqui, Fasahat Ullah; Teng, Shyh Wei; Awrangjeb, Mohammad; Lu, Guojun
2016-07-19
Existing automatic building extraction methods are not effective in extracting buildings which are small in size and have transparent roofs. The application of large area threshold prohibits detection of small buildings and the use of ground points in generating the building mask prevents detection of transparent buildings. In addition, the existing methods use numerous parameters to extract buildings in complex environments, e.g., hilly area and high vegetation. However, the empirical tuning of large number of parameters reduces the robustness of building extraction methods. This paper proposes a novel Gradient-based Building Extraction (GBE) method to address these limitations. The proposed method transforms the Light Detection And Ranging (LiDAR) height information into intensity image without interpolation of point heights and then analyses the gradient information in the image. Generally, building roof planes have a constant height change along the slope of a roof plane whereas trees have a random height change. With such an analysis, buildings of a greater range of sizes with a transparent or opaque roof can be extracted. In addition, a local colour matching approach is introduced as a post-processing stage to eliminate trees. This stage of our proposed method does not require any manual setting and all parameters are set automatically from the data. The other post processing stages including variance, point density and shadow elimination are also applied to verify the extracted buildings, where comparatively fewer empirically set parameters are used. The performance of the proposed GBE method is evaluated on two benchmark data sets by using the object and pixel based metrics (completeness, correctness and quality). Our experimental results show the effectiveness of the proposed method in eliminating trees, extracting buildings of all sizes, and extracting buildings with and without transparent roof. When compared with current state-of-the-art building extraction methods, the proposed method outperforms the existing methods in various evaluation metrics.
A Robust Gradient Based Method for Building Extraction from LiDAR and Photogrammetric Imagery
Siddiqui, Fasahat Ullah; Teng, Shyh Wei; Awrangjeb, Mohammad; Lu, Guojun
2016-01-01
Existing automatic building extraction methods are not effective in extracting buildings which are small in size and have transparent roofs. The application of large area threshold prohibits detection of small buildings and the use of ground points in generating the building mask prevents detection of transparent buildings. In addition, the existing methods use numerous parameters to extract buildings in complex environments, e.g., hilly area and high vegetation. However, the empirical tuning of large number of parameters reduces the robustness of building extraction methods. This paper proposes a novel Gradient-based Building Extraction (GBE) method to address these limitations. The proposed method transforms the Light Detection And Ranging (LiDAR) height information into intensity image without interpolation of point heights and then analyses the gradient information in the image. Generally, building roof planes have a constant height change along the slope of a roof plane whereas trees have a random height change. With such an analysis, buildings of a greater range of sizes with a transparent or opaque roof can be extracted. In addition, a local colour matching approach is introduced as a post-processing stage to eliminate trees. This stage of our proposed method does not require any manual setting and all parameters are set automatically from the data. The other post processing stages including variance, point density and shadow elimination are also applied to verify the extracted buildings, where comparatively fewer empirically set parameters are used. The performance of the proposed GBE method is evaluated on two benchmark data sets by using the object and pixel based metrics (completeness, correctness and quality). Our experimental results show the effectiveness of the proposed method in eliminating trees, extracting buildings of all sizes, and extracting buildings with and without transparent roof. When compared with current state-of-the-art building extraction methods, the proposed method outperforms the existing methods in various evaluation metrics. PMID:27447631
The human dimensions of energy use in buildings: A review
DOE Office of Scientific and Technical Information (OSTI.GOV)
D'Oca, Simona; Hong, Tianzhen; Langevin, Jared
The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.« less
The human dimensions of energy use in buildings: A review
D'Oca, Simona; Hong, Tianzhen; Langevin, Jared
2017-08-19
The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.« less
Brown, Michael J.; Williams, Michael D.; Nelson, Matthew A.; Werley, Kenneth A.
2015-01-01
The Quick Urban and Industrial Complex (QUIC) plume modeling system is used to explore how the transport and dispersion of vehicle emissions in cities are impacted by the presence of buildings. Using downtown Philadelphia as a test case, notional vehicle emissions of gases and particles are specified as line source releases on a subset of the east–west and north–south streets. Cases were run in flat terrain and with 3D buildings present in order to show the differences in the model-computed outdoor concentration fields with and without buildings present. The QUIC calculations show that buildings result in regions with much higher concentrations and other areas with much lower concentrations when compared to the flat-earth case. On the roads with vehicle emissions, street-level concentrations were up to a factor of 10 higher when buildings were on either side of the street as compared to the flat-earth case due to trapping of pollutants between buildings. However, on roads without vehicle emissions and in other open areas, the concentrations were up to a factor of 100 times smaller as compared to the flat earth case because of vertical mixing of the vehicle emissions to building height in the cavity circulation that develops on the downwind side of unsheltered buildings. QUIC was also used to calculate infiltration of the contaminant into the buildings. Indoor concentration levels were found to be much lower than outdoor concentrations because of deposition onto indoor surfaces and particulate capture for buildings with filtration systems. Large differences in indoor concentrations from building to building resulted from differences in leakiness, air handling unit volume exchange rates, and filter type and for naturally ventilated buildings, whether or not the building was sheltered from the prevailing wind by a building immediately upwind. PMID:27867300
Structural building screening and evaluation
NASA Astrophysics Data System (ADS)
Kurniawandy, Alex; Nakazawa, Shoji; Hendry, Andy; Ridwan, Firdaus, Rahmatul
2017-10-01
An earthquake is a disaster that can be harmful to the community, such as financial loss and also dead injuries. Pekanbaru is a city that located in the middle of Sumatera Island. Even though the city of Pekanbaru is a city that rarely occurs earthquake, but Pekanbaru has ever felt the impact of the big earthquake that occurred in West Sumatera on September 2009. As we know, Indonesia located between Eurasia plate, Pacific plate, and Indo-Australian plate. Particularly the Sumatera Island, It has the Semangko fault or the great Sumatra fault along the island from north to south due to the shift of Eurasia and Indo-Australian Plates. An earthquake is not killing people but the building around the people that could be killing them. The failure of the building can be early prevented by doing an evaluation. In this research, the methods of evaluation have used a guideline for the Federal Emergency Management Agency (FEMA) P-154 and Applied Technology Council (ATC) 40. FEMA P-154 is a rapid visual screening of buildings for potential seismic hazards and ATC-40 is seismic evaluation and retrofit of Concrete Buildings. ATC-40 is a more complex evaluation rather than FEMA P-154. The samples to be evaluated are taken in the surroundings of Universitas Riau facility in Pekanbaru. There are four buildings as case study such as the rent student building, the building of mathematics and natural science faculty, the building teacher training and education faculty and the buildings in the faculty of Social political sciences. Vulnerability for every building facing an earthquake is different, this is depending on structural and non-structural components of the building. Among all of the samples, only the building of mathematics and the natural science faculty is in critical condition according to the FEMA P-154 evaluation. Furthermore, the results of evaluation using ATC-40 for the teacher training building are in damage control conditions, despite the other three buildings are in immediate occupancy conditions.
Hybrid Modeling Based on Scsg-Br and Orthophoto
NASA Astrophysics Data System (ADS)
Zhou, G.; Huang, Y.; Yue, T.; Li, X.; Huang, W.; He, C.; Wu, Z.
2018-05-01
With the development of digital city, digital applications are more and more widespread, while the urban buildings are more complex. Therefore, establishing an effective data model is the key to express urban building models accurately. In addition, the combination of 3D building model and remote sensing data become a trend to build digital city there are a large amount of data resulting in data redundancy. In order to solve the limitation of single modelling of constructive solid geometry (CSG), this paper presents a mixed modelling method based on SCSG-BR for urban buildings representation. On one hand, the improved CSG method, which is called as "Spatial CSG (SCSG)" representation method, is used to represent the exterior shape of urban buildings. On the other hand, the boundary representation (BR) method represents the topological relationship between geometric elements of urban building, in which the textures is considered as the attribute data of the wall and the roof of urban building. What's more, the method combined file database and relational database is used to manage the data of three-dimensional building model, which can decrease the complex processes in texture mapping. During the data processing, the least-squares algorithm with constraints is used to orthogonalize the building polygons and adjust the polygons topology to ensure the accuracy of the modelling data. Finally, this paper matches the urban building model with the corresponding orthophoto. This paper selects data of Denver, Colorado, USA to establish urban building realistic model. The results show that the SCSG-BR method can represent the topological relations of building more precisely. The organization and management of urban building model data reduce the redundancy of data and improve modelling speed. The combination of orthophoto and urban building model further strengthens the application in view analysis and spatial query, which enhance the scope of digital city applications.
Energy audit role in building planning
NASA Astrophysics Data System (ADS)
Sipahutar, Riman; Bizzy, Irwin
2017-11-01
An energy audit is one way to overcome the excessive use of energy in buildings. The increasing growth of population, economy, and industry will have an impact on energy demand and the formation of greenhouse gas emissions. Indonesian National Standard (SNI) concerning the building has not been implemented optimally due to the socialization process by a government not yet been conducted. An energy audit of buildings has been carried out at offices and public services. Most electrical energy in buildings used for air refresher equipment or air conditioning. Calculation of OTTV has demonstrated the importance of performing since the beginning of the planning of a building to get energy-efficient buildings.
116. Photographic copy of drawing (25 June 1917, original drawing ...
116. Photographic copy of drawing (25 June 1917, original drawing in Archives, Office of the Building, Administration Building, Sears, Roebuck and Company Mail Order Plant, Chicago, Illinois). Drawn by Sears Department 131. 1/64 inch to one foot. Schematic plan of the Merchandise Building, describing the type of construction of the different portions of the building and shows the layout of the railroad tracks around the building. At the date of this drawing the building had all the major additons complete (to Annex A, Annex B, and the Box Factory). SCHETMATIC FLOOR PLAN - Sears Roebuck & Company Mail Order Plant, Merchandise Building, 924 South Homan Avenue, Chicago, Cook County, IL
Study of fuel cell on-site, integrated energy systems in residential/commercial applications
NASA Technical Reports Server (NTRS)
Wakefield, R. A.; Karamchetty, S.; Rand, R. H.; Ku, W. S.; Tekumalla, V.
1980-01-01
Three building applications were selected for a detailed study: a low rise apartment building; a retail store, and a hospital. Building design data were then specified for each application, based on the design and construction of typical, actual buildings. Finally, a computerized building loads analysis program was used to estimate hourly end use load profiles for each building. Conventional and fuel cell based energy systems were designed and simulated for each building in each location. Based on the results of a computer simulation of each energy system, levelized annual costs and annual energy consumptions were calculated for all systems.
Application of BIM Technology in Prefabricated Buildings
NASA Astrophysics Data System (ADS)
Zhanglin, Guo; Si, Gao; Jun-e, Liu
2017-08-01
The development of fabricated buildings has become the main trend of the developm ent of modern construction industry in China. As the main tool of building information, BIM (b uilding information modeling) has greatly promoted the development of construction industry. Based on the review of the papers about the fabricated buildings and BIM technology in recent years, this paper analyzes the advantages of fabricated buildings and BIM technology, then exp lores the application of BIM technology in fabricated buildings. It aims to realize the rationaliz ation and scientification of project lifecycle management in fabricated construction project, and finally form a coherent information platform in the fabricated building.
2. Historic American Buildings Survey, Louis I. Schwartz, Photographer July, ...
2. Historic American Buildings Survey, Louis I. Schwartz, Photographer July, 1962 SLAVE BUILDING AND KITCHENS. - Robinson-Aiken Slave Building & Kitchens, 48 Elizabeth Street, Charleston, Charleston County, SC
This Tribal Green Building Toolkit (Toolkit) is designed to help tribal officials, community members, planners, developers, and architects develop and adopt building codes to support green building practices. Anyone can use this toolkit!
Tribal Green Building Administrative Code Example
This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.
Simulation and visualization of energy-related occupant behavior in office buildings
Chen, Yixing; Liang, Xin; Hong, Tianzhen; ...
2017-03-15
In current building performance simulation programs, occupant presence and interactions with building systems are over-simplified and less indicative of real world scenarios, contributing to the discrepancies between simulated and actual energy use in buildings. Simulation results are normally presented using various types of charts. However, using those charts, it is difficult to visualize and communicate the importance of occupants’ behavior to building energy performance. This study introduced a new approach to simulating and visualizing energy-related occupant behavior in office buildings. First, the Occupancy Simulator was used to simulate the occupant presence and movement and generate occupant schedules for each spacemore » as well as for each occupant. Then an occupant behavior functional mockup unit (obFMU) was used to model occupant behavior and analyze their impact on building energy use through co-simulation with EnergyPlus. Finally, an agent-based model built upon AnyLogic was applied to visualize the simulation results of the occupant movement and interactions with building systems, as well as the related energy performance. A case study using a small office building in Miami, FL was presented to demonstrate the process and application of the Occupancy Simulator, the obFMU and EnergyPlus, and the AnyLogic module in simulation and visualization of energy-related occupant behaviors in office buildings. Furthermore, the presented approach provides a new detailed and visual way for policy makers, architects, engineers and building operators to better understand occupant energy behavior and their impact on energy use in buildings, which can improve the design and operation of low energy buildings.« less
Simulation and visualization of energy-related occupant behavior in office buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yixing; Liang, Xin; Hong, Tianzhen
In current building performance simulation programs, occupant presence and interactions with building systems are over-simplified and less indicative of real world scenarios, contributing to the discrepancies between simulated and actual energy use in buildings. Simulation results are normally presented using various types of charts. However, using those charts, it is difficult to visualize and communicate the importance of occupants’ behavior to building energy performance. This study introduced a new approach to simulating and visualizing energy-related occupant behavior in office buildings. First, the Occupancy Simulator was used to simulate the occupant presence and movement and generate occupant schedules for each spacemore » as well as for each occupant. Then an occupant behavior functional mockup unit (obFMU) was used to model occupant behavior and analyze their impact on building energy use through co-simulation with EnergyPlus. Finally, an agent-based model built upon AnyLogic was applied to visualize the simulation results of the occupant movement and interactions with building systems, as well as the related energy performance. A case study using a small office building in Miami, FL was presented to demonstrate the process and application of the Occupancy Simulator, the obFMU and EnergyPlus, and the AnyLogic module in simulation and visualization of energy-related occupant behaviors in office buildings. Furthermore, the presented approach provides a new detailed and visual way for policy makers, architects, engineers and building operators to better understand occupant energy behavior and their impact on energy use in buildings, which can improve the design and operation of low energy buildings.« less
The Creation of Space Vector Models of Buildings From RPAS Photogrammetry Data
NASA Astrophysics Data System (ADS)
Trhan, Ondrej
2017-06-01
The results of Remote Piloted Aircraft System (RPAS) photogrammetry are digital surface models and orthophotos. The main problem of the digital surface models obtained is that buildings are not perpendicular and the shape of roofs is deformed. The task of this paper is to obtain a more accurate digital surface model using building reconstructions. The paper discusses the problem of obtaining and approximating building footprints, reconstructing the final spatial vector digital building model, and modifying the buildings on the digital surface model.
Strategies to integrate patient and family education into patient care redesign.
Yingling, L; Trocino, L
1997-05-01
This article discusses five strategies to effectively integrate patient and family education into patient care redesign. The strategies include building the plan, building a shared mission and vision, building involvement, building collaboration through initiatives, and building accountability. Each strategy or "building block" is vital to the resulting structure of patient and family education. Effective results of the strategies are discussed as milestones. The process must be ongoing to ensure continuous improvement in quality patient care outcomes, consumer satisfaction and cost-effectiveness.
8. Historic view of the building: 'Warren Street from State ...
8. Historic view of the building: 'Warren Street from State Street' ca. 1890. Courtesy of the Trenton Free Public Library. This shows the building before the True American's renovations of 1893. It is the three-story buildings, flanked by lower ones in the middle of the block. At the time of the photograph, the brick exterior was painted a light color and dark-colored louvered shutters flanked all the upper story windows. - 14 North Warren Street (Commercial Building), True American Building, Trenton, Mercer County, NJ
NASA Astrophysics Data System (ADS)
Alsabry, A.; Truszkiewicz, P.; Szymański, K.; Łaskawiec, K.; Rojek, Ł.
2017-12-01
The article presents an analysis of buildings belonging the Department of Public Utilities and Housing in Zielona Góra. The research was based on a set of questions for building operators. The questionnaires consisted of 30 questions concerning general and detailed information about the buildings. In order to clearly present the results, this article includes data only about residential and residential-commercial buildings. Forty building built in different periods were selected for analysis.
Building America Systems Integration Research Annual Report. FY 2012
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gestwick, Michael
2013-05-01
This Building America FY2012 Annual Report includes an overview of the Building America Program activities and the work completed by the National Renewable Energy Laboratory and the Building America industry consortia (the Building America teams). The annual report summarizes major technical accomplishments and progress towards U.S. Department of Energy Building Technologies Program's multi-year goal of developing the systems innovations that enable risk-free, cost effective, reliable and durable efficiency solutions that reduce energy use by 30%-50% in both new and existing homes.
Energy consumption in commercial buildings: A comparison with BEPS budgets
NASA Astrophysics Data System (ADS)
1980-09-01
Metered energy consumption data were collected on existing commercial buildings to help establish the proposed building energy performance standards (BEPS). The search has identified 84 buildings whose metered energy consumption is equal to or less than that proposed for their BEPS budgets and another 7 buildings whose metered consumption is less than 20 percent above their BEPS budgets. The methodology used to identify the buildings and to collect their metered energy consumption data are described. The data are analyzed and summarized and conclusions are drawn.
Smart Buildings: An Introduction to the Library of the Future.
Hoy, Matthew B
2016-01-01
Advances in building technologies are combining energy efficiency, networked sensors, and data recording in exciting ways. Modern facilities can adjust lighting, heating, and cooling outputs to maximize efficiency, provide better physical security, improve wayfinding for occupants, and provide detailed reports of building use. This column will briefly explore the idea of "smart buildings," describe some of the technologies that are being developed for these buildings, and explore their implications for libraries. A brief listing of selected smart building technologies is also provided.
HOT CELL BUILDING, TRA632. CONTEXTUAL VIEW ALONG WALLEYE AVENUE, CAMERA ...
HOT CELL BUILDING, TRA-632. CONTEXTUAL VIEW ALONG WALLEYE AVENUE, CAMERA FACING EASTERLY. HOT CELL BUILDING IS AT CENTER LEFT OF VIEW; THE LOW-BAY PROJECTION WITH LADDER IS THE TEST TRAIN ASSEMBLY FACILITY, ADDED IN 1968. MTR BUILDING IS IN LEFT OF VIEW. HIGH-BAY BUILDING AT RIGHT IS THE ENGINEERING TEST REACTOR BUILDING, TRA-642. INL NEGATIVE NO. HD46-32-1. Mike Crane, Photographer, 4/2005 - Idaho National Engineering Laboratory, Test Reactor Area, Materials & Engineering Test Reactors, Scoville, Butte County, ID
Study of intelligent building system based on the internet of things
NASA Astrophysics Data System (ADS)
Wan, Liyong; Xu, Renbo
2017-03-01
In accordance with the problem such as isolated subsystems, weak system linkage and expansibility of the bus type buildings management system, this paper based on the modern intelligent buildings has studied some related technologies of the intelligent buildings and internet of things, and designed system architecture of the intelligent buildings based on the Internet of Things. Meanwhile, this paper has also analyzed wireless networking modes, wireless communication protocol and wireless routing protocol of the intelligent buildings based on the Internet of Things.
Credit PSR. View looks north northeast (20°) at the concrete ...
Credit PSR. View looks north northeast (20°) at the concrete pad which forms the top of the sump pump facility. In the background stand Building 4303 (Air Compressor Building), Building 4307 (Supply and Equipment Warehouse) at left, Building 4305 (Unicon Portable Hangar) at center, and Building 4306 (Boiler House) at right. Sign marking Building 4302 was made from a disused road sign from somewhere on Edwards AFB - Edwards Air Force Base, North Base, Sump Pump, East of Second Street, Boron, Kern County, CA
SPERTI Instrument Cell Building (PER606) elevation; plan of Guard House ...
SPERT-I Instrument Cell Building (PER-606) elevation; plan of Guard House (PER-607); elevations for Pit Building (PER-605) southwest, southeast, and northeast sides. Earthen shield is mounded between back wall of Instrument Cell Building and the southwest elevation of Pit Building. Detail of filtered louver in door of Instrument Cell Building. Idaho Operations Office PER-605-IDO-3. INEEL index no. 761-0605-00-396-109183 - Idaho National Engineering Laboratory, SPERT-I & Power Burst Facility Area, Scoville, Butte County, ID
16. A southward view of buildings #6B, #6, #6A, #7, ...
16. A southward view of buildings #6-B, #6, #6-A, #7, #8-A, and #8. The water tower is situated directly behind building #8. To the right ia the eastern wall of the five-storied building #5. In the center background is part of the north face of building #9. All structures to the north of building #9 are to be demolished. - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA
Bassett, David R; Browning, Ray; Conger, Scott A; Wolff, Dana L; Flynn, Jennifer I
2013-05-01
The indoor built environment has the potential to influence levels of physical activity. However, the extent to which architectural design in commercial buildings can influence the percentage of people choosing to use the stairs versus elevators is unknown. The purpose of this study was to determine if buildings with centrally located, accessible, and aesthetically pleasing staircases result in a greater percentage of people taking the stairs. Direct observations of stair and elevator use were conducted in 3 buildings on a university campus. One of the buildings had a bank of 4 centrally located elevators and a fire escape stairwell behind a steel door. The other 2 buildings had centrally located staircases and out-of-the-way elevators. The percentage of people who ascended the stairs was 8.1% in the elevator-centric building, compared with 72.8% and 81.1% in the 2 stair-centric buildings (P < .001). In addition, the percentage of people who descended the stairs was 10.8% in the first building, compared with 89.5% and 93.7% in the stair-centric buildings (P < .001). The results of the current study suggest that if buildings are constructed with centrally located, accessible, and aesthetically pleasing staircases, a greater percentage of people will choose to take the stairs.
Performative building envelope design correlated to solar radiation and cooling energy consumption
NASA Astrophysics Data System (ADS)
Jacky, Thiodore; Santoni
2017-11-01
Climate change as an ongoing anthropogenic environmental challenge is predominantly caused by an amplification in the amount of greenhouse gases (GHGs), notably carbon dioxide (CO2) in building sector. Global CO2 emissions are emitted from HVAC (Heating, Ventilation, and Air Conditioning) occupation to provide thermal comfort in building. In fact, the amount of energy used for cooling or heating building is implication of building envelope design. Building envelope acts as interface layer of heat transfer between outdoor environment and the interior of a building. It appears as wall, window, roof and external shading device. This paper examines performance of various design strategy on building envelope to limit solar radiation and reduce cooling loads in tropical climate. The design strategies are considering orientation, window to wall ratio, material properties, and external shading device. This research applied simulation method using Autodesk Ecotect to investigate simultaneously between variations of wall and window ratio, shading device composition and the implication to the amount of solar radiation, cooling energy consumption. Comparative analysis on the data will determine logical variation between opening and shading device composition and cooling energy consumption. Optimizing the building envelope design is crucial strategy for reducing CO2 emissions and long-term energy reduction in building sector. Simulation technology as feedback loop will lead to better performative building envelope.
North side, looking southeast. Leading to building 513. Fitzsimons ...
North side, looking southeast. Leading to building 513. - Fitzsimons General Hospital, Dental Laboratory, North of Building No. 511, West of corridor connecting Buildings 511 & 515, Aurora, Adams County, CO
18. VIEW OF THE NORTH ELEVATION OF BUILDING 71 (771) ...
18. VIEW OF THE NORTH ELEVATION OF BUILDING 71 (771) UNDER CONSTRUCTION IN 1952. BUILDING 71 WAS THE ORIGINAL PLUTONIUM OPERATIONS BUILDING. PRODUCTION BUILDINGS WERE BUILT INTO HILLSIDES AND/OR BELOW GRADE AS A SAFETY MEASURE AGAINST RUSSIAN ATTACK (3/2/52). - Rocky Flats Plant, Bounded by Indiana Street & Routes 93, 128 & 72, Golden, Jefferson County, CO
1994-06-01
The big news this week is that prefabricated buildings are no longer viewed as a poor substitute for traditional buildings. That's what it says here, anyway. In a press release headed Future looking bright for prefabricated building industry', Rovacabin - 'leading suppliers of modular and portable buildings' - says average turnover in the prefab, building industry rose by 20 per cent in the second half of 1993.
VIEW NORTH EXTREME LEFTBUILDING 32; MACHINE SHOP (1890) SECOND LEFTBUILDING ...
VIEW NORTH- EXTREME LEFT-BUILDING 32; MACHINE SHOP (1890) SECOND LEFT-BUILDING 31; RIGGER SHOP (1890) CENTER- BUILDING 28; BLACKSMITH SHOP (1885) CENTER RIGHT-BUILDING 27; PATTERN SHOP (C.1853) RIGHT-BUILDING 40; WIRE WAREHOUSE (1915) - John A. Roebling's Sons Company & American Steel & Wire Company, South Broad, Clark, Elmer, Mott & Hudson Streets, Trenton, Mercer County, NJ
ERIC Educational Resources Information Center
Tsai, Pei-Shan; Chai, Ching Sing; Hong, Huang-Yao; Koh, Joyce Hwee Ling
2017-01-01
The purpose of this study is to investigate the relationships among students' conceptions of knowledge building, approaches to knowledge building, knowledge-building behaviors and learning outcomes. A total of 48 primary school students (from grades 3 and 4) who had experienced knowledge-building activities participated in the present study. After…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-01
... Buildings Service; Submission for OMB Review; Application/ Permit for Use of Space in Public Buildings and Grounds, GSA Form 3453 AGENCY: Public Buildings Service, GSA. ACTION: Notice of request for comments... regarding GSA Form 3453, Application/Permit for Use of Space in Public Buildings and Grounds. A notice was...
46 CFR 67.101 - Waiver of evidence of build.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 2 2010-10-01 2010-10-01 false Waiver of evidence of build. 67.101 Section 67.101... DOCUMENTATION OF VESSELS Build Requirements for Vessel Documentation § 67.101 Waiver of evidence of build. (a) A vessel owner applying for documentation unable to obtain the evidence of build required by § 67.99 may...
Building Momentum: National Trends and Prospects for High-Performance Green Buildings.
ERIC Educational Resources Information Center
2003
This report is an outgrowth of the Green Building Roundtable of the U.S. Senate Committee on Environment and Public Works held in conjunction with the U.S. Green Building Council on April 24, 2002. The roundtable brought together diverse interests to educate members of Congress on green building trends and generated discussion about the economic…
Building Green: The Adoption Process of LEED- and Energy Star-Rated Office Buildings
ERIC Educational Resources Information Center
Malkani, Arvin P.
2012-01-01
There are opportunities for green building technology in office buildings to produce energy savings and cost efficiencies that can produce a positive economic and environmental impact. In order for these opportunities to be realized, however, decision makers must appreciate the value of green building technology. The objective of this research is…
Exterior building details of Building C, east façade: inscribed date ...
Exterior building details of Building C, east façade: inscribed date panel "hospital 1885", corbelled brick belt course, parapet, second floor historic four-over-four window with brick lintels, quoins and decorative metal grilled, cantilever wooden walkway; westerly view - San Quentin State Prison, Building 22, Point San Quentin, San Quentin, Marin County, CA
Russia’s R&D for Low Energy Buildings: Insights for Cooperation with Russia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schaaf, Rebecca E.; Evans, Meredydd
Russian buildings, Russian buildings sector energy consumption. Russian government has made R&D investment a priority again. The government and private sector both invest in a range of building energy technologies. In particular, heating, ventilation and air conditioning, district heating, building envelope, and lighting have active technology research projects and programs in Russia.
Checklist of Library Building Design Considerations.
ERIC Educational Resources Information Center
Sannwald, William W., Ed.; Smith, Robert S., Ed.
This checklist is designed to provide librarians, architects, and other members of a building design team with a list of questions to ask during the design phase of a new or remodeled library building project. The purpose of the questions is to make sure that no element of the building is overlooked by the building design team in their programming…
ERIC Educational Resources Information Center
Wu, Wei
2010-01-01
Building information modeling (BIM) and green building are currently two major trends in the architecture, engineering and construction (AEC) industry. This research recognizes the market demand for better solutions to achieve green building certification such as LEED in the United States. It proposes a new strategy based on the integration of BIM…
1. EXTERIOR OF BUILDING 125 FROM MAIN PLANT 4 RESIDENTIAL ...
1. EXTERIOR OF BUILDING 125 FROM MAIN PLANT 4 RESIDENTIAL STREET SHOWING BUILDING AT PHOTO RIGHT CENTER (WITH WHITE JEEP PARKED IN FRONT) BETWEEN WORKER COTTAGE (BUILDING 115) AT PHOTO LEFT AND RECREATION HALL (BUILDING 109) AT PHOTO RIGHT. VIEW TO SOUTH. - Bishop Creek Hydroelectric System, Plant 4, Lightning Arrestor Vault, Bishop Creek, Bishop, Inyo County, CA
7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 12 2013-01-01 2013-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...
7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 12 2014-01-01 2013-01-01 true Voluntary National Model Building Codes E Exhibit E to... Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of this...
7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 12 2012-01-01 2012-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...
Simplified Floor-Area-Based Energy-Moisture-Economic Model for Residential Buildings
ERIC Educational Resources Information Center
Martinez, Luis A.
2009-01-01
In the United States, 21% of all energy is used in residential buildings (40% of which is for heating and cooling homes). Promising improvements in residential building energy efficiency are underway such as the Building America Program and the Passive House Concept. The ability of improving energy efficiency in buildings is enhanced by building…
2. Basement tunnel plan: Pine (Building 6, HABS DC349AA), Linden ...
2. Basement tunnel plan: Pine (Building 6, HABS DC-349-AA), Linden (Building 28 HABS DC-349-AD), Holly (Building 29, HABS DC-349-AE), East Lodge / Detached Nurses Home (Building 30, HABS DC-349-AB) - St. Elizabeths Hospital, Tunnels, 2700 Martin Luther King Jr. Avenue, Southeast, Washington, District of Columbia, DC
1. AERIAL VIEW, LOOKING SOUTH, ALONG 20TH STREET NORTH WITH ...
1. AERIAL VIEW, LOOKING SOUTH, ALONG 20TH STREET NORTH WITH EMPIRE BUILDING (CENTER RIGHT), WOODWARD BUILDING (CENTER), JOHN HAND BUILDING (TOP LEFT), BROWN MARX BUILDING (BOTTOM LEFT), THE FOUR BUILDINGS THAT COMPRISE THIS NATIONAL REGISTER HISTORIC DISTRICT - Heaviest Corner on Earth (Commercial), First Avenue, North & Twentieth (20th) Street, North, Birmingham, Jefferson County, AL
Credit PSR. View looks east southeast (118°) across foundations of ...
Credit PSR. View looks east southeast (118°) across foundations of North Base Administration Building (originally numbered T-50) toward Building 4318 (Warehouse) and Building 4305 (Unicon Portable Hangar). Building 4401 (Hangar No. 1) appears in extreme left background - Edwards Air Force Base, North Base, Administration Building T-50, D Street, Boron, Kern County, CA
Whole-Building Retrofits | Climate Neutral Research Campuses | NREL
Whole-Building Retrofits Whole-Building Retrofits Buildings are the greatest energy consumers on check. As buildings age, O&M costs reach the point where they are best addressed through a top-to wall insulation. Renovations are costly and disruptive, but they are the best way to adapt an aging
Ontology for Life-Cycle Modeling of Electrical Distribution Systems: Model View Definition
2013-06-01
building information models ( BIM ) at the coordinated design stage of building construction. 1.3 Approach To...standard for exchanging Building Information Modeling ( BIM ) data, which defines hundreds of classes for common use in software, currently supported by...specifications, Construction Operations Building in- formation exchange (COBie), Building Information Modeling ( BIM ) 16. SECURITY CLASSIFICATION OF:
Overview of Commercial Buildings, 2003
2008-01-01
The Energy Information Administration conducts the Commercial Buildings Energy Consumption Survey (CBECS) to collect information on energy-related building characteristics and types and amounts of energy consumed in commercial buildings in the United States.
10. Historic American Buildings Survey Ronald Partridge, Photographer August 1962 ...
10. Historic American Buildings Survey Ronald Partridge, Photographer August 1962 COLUMN ORNAMENT AT 226 'K' Street (Stanford Building) - Big Four Building, 220-226 K Street, Sacramento, Sacramento County, CA
Contextual view of building, with building #11 in right foreground. ...
Contextual view of building, with building #11 in right foreground. Camera facing east - Naval Supply Center, Broadway Complex, Administration Storehouse, 911 West Broadway, San Diego, San Diego County, CA
9. Historic American Buildings Survey E. W. Russell, Photographer, February ...
9. Historic American Buildings Survey E. W. Russell, Photographer, February 28, 1935 MAIN BUILDING (ADMINISTRATION) WEST - Spring Hill College, Main Building, Old Shell Road, Spring Hill, Mobile County, AL
Occupant comfort and health in green and conventional university buildings.
Hedge, A; Miller, L; Dorsey, J A
2014-01-01
Green building standards are significantly impacting modern construction practices. The resulting structures are more energy efficient, but their impact on occupant health has not been widely studied. To investigate a range of indoor environment and ergonomic issues in green buildings. Retrospective post-occupancy evaluation survey of 319 occupants in two Leadership in Energy and Environmental Design (LEED) certified buildings and one conventional building on a Canadian University campus. Results show that working in the LEED buildings was a generally positive experience for their health, performance, and satisfaction. However, the LEED buildings did not always receive the highest ratings for environmental conditions or for health and productivity. Respondents indicated a range of concerns with thermal conditions, office lighting, noise and their overall workstation designs and these were not always better in the green buildings. These results highlight the need for better integration of ergonomic design into green buildings and into the LEED rating system, and these implications are discussed.
Effect of strong-column weak-beam design provision on the seismic fragility of RC frame buildings
NASA Astrophysics Data System (ADS)
Surana, Mitesh; Singh, Yogendra; Lang, Dominik H.
2018-04-01
Incremental dynamic analyses are conducted for a suite of low- and mid-rise reinforced-concrete special moment-resisting frame buildings. Buildings non-conforming and conforming to the strong-column weak-beam (SCWB) design criterion are considered. These buildings are designed for the two most severe seismic zones in India (i.e., zone IV and zone V) following the provisions of Indian Standards. It is observed that buildings non-conforming to the SCWB design criterion lead to an undesirable column failure collapse mechanism. Although yielding of columns cannot be avoided, even for buildings conforming to a SCWB ratio of 1.4, the observed collapse mechanism changes to a beam failure mechanism. This change in collapse mechanism leads to a significant increase in the building's global ductility capacity, and thereby in collapse capacity. The fragility analysis study of the considered buildings suggests that considering the SCWB design criterion leads to a significant reduction in collapse probability, particularly in the case of mid-rise buildings.
Big data analytics in the building industry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Berger, Michael A.; Mathew, Paul A.; Walter, Travis
Catalyzed by recent market, technology, and policy trends, energy data collection in the building industry is becoming more widespread. This wealth of information allows more data-driven decision-making by designers, commissioning agents, facilities staff, and energy service providers during the course of building design, operation and retrofit. The U.S. Department of Energy’s Building Performance Database (BPD) has taken advantage of this wealth of building asset- and energy-related data by collecting, cleansing, and standardizing data from across the U.S. on over 870,00 buildings, and is designed to support building benchmarking, energy efficiency project design, and buildings-related policy development with real-world data. Here,more » this article explores the promises and perils energy professionals are faced with when leveraging such tools, presenting example analyses for commercial and residential buildings, highlighting potential issues, and discussing solutions and best practices that will enable designers, operators and commissioning agents to make the most of ‘big data’ resources such as the BPD.« less
NASA Astrophysics Data System (ADS)
Ham, S.; Oh, Y.; Choi, K.; Lee, I.
2018-05-01
Detecting unregistered buildings from aerial images is an important task for urban management such as inspection of illegal buildings in green belt or update of GIS database. Moreover, the data acquisition platform of photogrammetry is evolving from manned aircraft to UAVs (Unmanned Aerial Vehicles). However, it is very costly and time-consuming to detect unregistered buildings from UAV images since the interpretation of aerial images still relies on manual efforts. To overcome this problem, we propose a system which automatically detects unregistered buildings from UAV images based on deep learning methods. Specifically, we train a deconvolutional network with publicly opened geospatial data, semantically segment a given UAV image into a building probability map and compare the building map with existing GIS data. Through this procedure, we could detect unregistered buildings from UAV images automatically and efficiently. We expect that the proposed system can be applied for various urban management tasks such as monitoring illegal buildings or illegal land-use change.
The prediction of engineering cost for green buildings based on information entropy
NASA Astrophysics Data System (ADS)
Liang, Guoqiang; Huang, Jinglian
2018-03-01
Green building is the developing trend in the world building industry. Additionally, construction costs are an essential consideration in building constructions. Therefore, it is necessary to investigate the problems of cost prediction in green building. On the basis of analyzing the cost of green building, this paper proposes the forecasting method of actual cost in green building based on information entropy and provides the forecasting working procedure. Using the probability density obtained from statistical data, such as labor costs, material costs, machinery costs, administration costs, profits, risk costs a unit project quotation and etc., situations can be predicted which lead to cost variations between budgeted cost and actual cost in constructions, through estimating the information entropy of budgeted cost and actual cost. The research results of this article have a practical significance in cost control of green building. Additionally, the method proposed in this article can be generalized and applied to a variety of other aspects in building management.
Retrofitting solutions for two different occupancy levels of educational buildings in tropics
NASA Astrophysics Data System (ADS)
Yang, Junjing; Pantazaras, Alexandros; Lee, Siew Eang; Santamouris, Mattheos
2018-01-01
Within the multi-functionality of educational buildings, the energy conservation potential can be very different. In addition, among different retrofitting solutions investigated involving interventions on the building envelope, ventilation strategies, artificial lighting systems as well as equipment upgrading, different saving potential would come from different aspects. The opportunities for energy saving potential from the overall point of view and from the detailed aspect view of different retrofitting solutions would be very useful and important for building renovation decision making. This study presents a detailed retrofitting study of two different educational buildings. One represents a building with average occupancy variation and containing mainly offices and labs. The other one represents a building with high occupancy variation and containing mainly lecture rooms and studios. This comparison of the results gives an idea of the different energy saving potential for different types of educational buildings. Principal component analysis is also adopted to investigate the detailed performance of one of the buildings which is influenced stronger by these retrofitting solutions.
Advanced Energy Design Guide K-12: Next Generation of School Design and Operation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torcellini, Paul A; Pless, Shanti
Driven by energy efficiency advances and renewable energy cost reductions, zero energy buildings are popping up all around the country. Although zero energy represents a bold paradigm shift - from buildings that consume energy to buildings that produce enough energy to meet their energy needs on an annual basis - it isn't a sudden shift. Zero energy buildings are the result of steady, incremental progress by researchers and building professionals working together to improve building energy performance. ASHRAE is taking the lead by publishing - in partnership with the American Institute of Architects (AIA), the Illuminating Engineering Society (IES), themore » U.S. Green Building Council (USGBC), and the U.S. Department of Energy (DOE) - a new series of advanced energy design guides (AEDGs) focused on zero energy buildings. The recently completed Advanced Energy Design Guide for K-12 School Buildings: Achieving Zero Energy (K-12 ZE AEDG) is the first in this series.« less
Strength, functionality and beauty of university buildings in earthquake-prone countries
WADA, Akira
2018-01-01
Strength, functionality and beauty are the three qualities identifying well-designed architecture. For buildings in earthquake-prone countries such as Japan, emphasis on seismic safety frequently leads to the sacrifice of functionality and beauty. Therefore, it is important to develop new structural technologies that can ensure the seismic performance of a building without hampering the pursuit of functionality and beauty. The moment-resisting frame structures widely used for buildings in Japan are likely to experience weak-story collapse. Pin-supported walls, which can effectively enhance the structural story-by-story integrity of a building, were introduced to prevent such an unfavorable failure pattern in the seismic retrofit of an eleven-story building on a university campus in Tokyo, while also greatly aesthetically enhancing the façade of the building. The slight damage observed and monitoring records of the retrofitted building during the 2011 Tohoku earthquake in Japan demonstrate that the pin-supported walls worked as intended, protecting the building and guaranteeing the safety of its occupants during the earthquake. PMID:29434079
Terwilliger, Thomas C.; Grosse-Kunstleve, Ralf W.; Afonine, Pavel V.; Moriarty, Nigel W.; Zwart, Peter H.; Hung, Li-Wei; Read, Randy J.; Adams, Paul D.
2008-01-01
The PHENIX AutoBuild wizard is a highly automated tool for iterative model building, structure refinement and density modification using RESOLVE model building, RESOLVE statistical density modification and phenix.refine structure refinement. Recent advances in the AutoBuild wizard and phenix.refine include automated detection and application of NCS from models as they are built, extensive model-completion algorithms and automated solvent-molecule picking. Model-completion algorithms in the AutoBuild wizard include loop building, crossovers between chains in different models of a structure and side-chain optimization. The AutoBuild wizard has been applied to a set of 48 structures at resolutions ranging from 1.1 to 3.2 Å, resulting in a mean R factor of 0.24 and a mean free R factor of 0.29. The R factor of the final model is dependent on the quality of the starting electron density and is relatively independent of resolution. PMID:18094468
Big data analytics in the building industry
Berger, Michael A.; Mathew, Paul A.; Walter, Travis
2016-07-01
Catalyzed by recent market, technology, and policy trends, energy data collection in the building industry is becoming more widespread. This wealth of information allows more data-driven decision-making by designers, commissioning agents, facilities staff, and energy service providers during the course of building design, operation and retrofit. The U.S. Department of Energy’s Building Performance Database (BPD) has taken advantage of this wealth of building asset- and energy-related data by collecting, cleansing, and standardizing data from across the U.S. on over 870,00 buildings, and is designed to support building benchmarking, energy efficiency project design, and buildings-related policy development with real-world data. Here,more » this article explores the promises and perils energy professionals are faced with when leveraging such tools, presenting example analyses for commercial and residential buildings, highlighting potential issues, and discussing solutions and best practices that will enable designers, operators and commissioning agents to make the most of ‘big data’ resources such as the BPD.« less
High-Resolution Remote Sensing Image Building Extraction Based on Markov Model
NASA Astrophysics Data System (ADS)
Zhao, W.; Yan, L.; Chang, Y.; Gong, L.
2018-04-01
With the increase of resolution, remote sensing images have the characteristics of increased information load, increased noise, more complex feature geometry and texture information, which makes the extraction of building information more difficult. To solve this problem, this paper designs a high resolution remote sensing image building extraction method based on Markov model. This method introduces Contourlet domain map clustering and Markov model, captures and enhances the contour and texture information of high-resolution remote sensing image features in multiple directions, and further designs the spectral feature index that can characterize "pseudo-buildings" in the building area. Through the multi-scale segmentation and extraction of image features, the fine extraction from the building area to the building is realized. Experiments show that this method can restrain the noise of high-resolution remote sensing images, reduce the interference of non-target ground texture information, and remove the shadow, vegetation and other pseudo-building information, compared with the traditional pixel-level image information extraction, better performance in building extraction precision, accuracy and completeness.
Indoor Air Quality Building Education and Assessment Model Forms
The Indoor Air Quality Building Education and Assessment Model (I-BEAM) is a guidance tool designed for use by building professionals and others interested in indoor air quality in commercial buildings.
Contextual view including south (rear) of building 925, exercise in ...
Contextual view including south (rear) of building 925, exercise in foreground, and modern buildings in background. Facing northwest. - Travis Air Force Base, Building No. 925, W Street, Fairfield, Solano County, CA
View showing base of Building 70021 with Building 70022 in ...
View showing base of Building 70021 with Building 70022 in background, facing southeast - Naval Ordnance Test Station Inyokern, Randsburg Wash Facility Target Test Towers, Tower Road, China Lake, Kern County, CA
Detail view of base of Building 70021, showing Building 70022 ...
Detail view of base of Building 70021, showing Building 70022 (background), facing southeast - Naval Ordnance Test Station Inyokern, Randsburg Wash Facility Target Test Towers, Tower Road, China Lake, Kern County, CA
76 FR 63913 - Commercial Building Workforce Job/Task Analyses
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-14
..., Commercial Building Energy Modeler, Commissioning/Retro-Commissioning Authority, Energy/Sustainability..., Commercial Building Energy Modeler, Commissioning/Retro-Commissioning Authority, Energy/Sustainability...-commissioning authority, energy/sustainability manager, facility manager, and/or operating engineer/building...
51. BUILDING NO. 533, SOLVENT RECOVERY BUILDING, LOOKING WEST AT ...
51. BUILDING NO. 533, SOLVENT RECOVERY BUILDING, LOOKING WEST AT SOUTHEAST (REAR) ELEVATION. - Picatinny Arsenal, 500 Area, Powder Factory & Power House, State Route 15 near I-80, Dover, Morris County, NJ
18. Walkway between maintenance building and office building along south ...
18. Walkway between maintenance building and office building along south side of main plant looking east - Skinner Meat Packing Plant, Main Plant, 6006 South Twenty-seventh Street, Omaha, Douglas County, NE
8. PHOTOCOPY, HEATING DRAWING FOR ADMINISTRATION BUILDING. NIKE Missile ...
8. PHOTOCOPY, HEATING DRAWING FOR ADMINISTRATION BUILDING. - NIKE Missile Base SL-40, Administration Building, East central portion of base, southeast of Mess Hall, northeast of HIPAR Equipment Building, Hecker, Monroe County, IL
1. ADMINISTRATION BUILDING, RIGHT SIDE, LOOKING SOUTH. NIKE Missile ...
1. ADMINISTRATION BUILDING, RIGHT SIDE, LOOKING SOUTH. - NIKE Missile Base SL-40, Administration Building, East central portion of base, southeast of Mess Hall, northeast of HIPAR Equipment Building, Hecker, Monroe County, IL
7. PHOTOCOPY, ELEVATION DRAWING OF ADMINISTRATION BUILDING. NIKE Missile ...
7. PHOTOCOPY, ELEVATION DRAWING OF ADMINISTRATION BUILDING. - NIKE Missile Base SL-40, Administration Building, East central portion of base, southeast of Mess Hall, northeast of HIPAR Equipment Building, Hecker, Monroe County, IL
2. ADMINISTRATION BUILDING, REAR SIDE, LOOKING EAST. NIKE Missile ...
2. ADMINISTRATION BUILDING, REAR SIDE, LOOKING EAST. - NIKE Missile Base SL-40, Administration Building, East central portion of base, southeast of Mess Hall, northeast of HIPAR Equipment Building, Hecker, Monroe County, IL
3. ADMINISTRATION BUILDING, LEFT SIDE, LOOKING NORTH. NIKE Missile ...
3. ADMINISTRATION BUILDING, LEFT SIDE, LOOKING NORTH. - NIKE Missile Base SL-40, Administration Building, East central portion of base, southeast of Mess Hall, northeast of HIPAR Equipment Building, Hecker, Monroe County, IL
NASA Technical Reports Server (NTRS)
1996-01-01
Building 1100 is the NASA administrative building. Services located in this building include two banks, a post office, barber shop, cafeteria, snack bar, travel agency, dry cleaners, the NASA Exchange retail store and medical facilities for employees.
1. Historic American Buildings Survey A. Lewis Koue, Photographer Photo: ...
1. Historic American Buildings Survey A. Lewis Koue, Photographer Photo: May 1933 ACADEMIC BUILDING (Southeast Elevation) - El Colegio de San Jose, Academic Building, Rancho El Alisal, Salinas, Monterey County, CA
63. BUILDING NO. 1301, ORDNANCE FACILITY (MORTAR POWDER BUILDING), INTERIOR, ...
63. BUILDING NO. 1301, ORDNANCE FACILITY (MORTAR POWDER BUILDING), INTERIOR, LOOKING SOUTHEAST DOWN SCREENED WALKWAY ON NORTHWEST SIDE. - Picatinny Arsenal, State Route 15 near I-80, Dover, Morris County, NJ
Building Efficiency Evaluation and Uncertainty Analysis with DOE's Asset Score Preview
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-08-12
Building Energy Asset Score Tool, developed by the U.S. Department of Energy (DOE), is a program to encourage energy efficiency improvement by helping building owners and managers assess a building's energy-related systems independent of operations and maintenance. Asset Score Tool uses a simplified EnergyPlus model to provide an assessment of building systems, through minimum user inputs of basic building characteristics. Asset Score Preview is a newly developed option that allows users to assess their building's systems and the potential value of a more in-depth analysis via an even more simplified approach. This methodology provides a preliminary approach to estimating amore » building's energy efficiency and potential for improvement. This paper provides an overview of the methodology used for the development of Asset Score Preview and the scoring methodology.« less
Dynamics of airborne fungal populations in a large office building
NASA Technical Reports Server (NTRS)
Burge, H. A.; Pierson, D. L.; Groves, T. O.; Strawn, K. F.; Mishra, S. K.
2000-01-01
The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.
Patterson, Bradley M; Davis, Greg B
2009-02-01
Potential hydrocarbon-vapor intrusion pathways into a building through a concrete slab-on-ground were investigated and quantified under a variety of environmental conditions to elucidate the potential mechanisms for indoor air contamination. Vapor discharge from the uncovered open ground soil adjacent to the building and subsequent advection into the building was unlikely due to the low soil-gas concentrations at the edge of the building as a result of aerobic biodegradation of hydrocarbon vapors. When the building's interior was under ambient pressure, a flux of vapors into the building due to molecular diffusion of vapors through the building's concrete slab (cyclohexane 11 and methylcyclohexane 31 mg m(-2) concrete slab day(-1)) and short-term (up to 8 h) cyclical pressure-driven advection of vapors through an artificial crack (cyclohexane 4.2 x 10(3) and methylcyclohexane 1.2 x 10(4) mg m(-2) cracks day(-1)) was observed. The average subslab vapor concentration under the center of the building was 25,000 microg L(-1). Based on the measured building's interiorvapor concentrations and the building's air exchange rate of 0.66 h(-1), diffusion of vapors through the concrete slab was the dominantvapor intrusion pathway and cyclical pressure exchanges resulted in a near zero advective flux. When the building's interior was under a reduced pressure (-12 Pa), advective transport through cracks or gaps in the concrete slab (cyclohexane 340 and methylcyclohexane 1100 mg m(-2) cracks day(-1)) was the dominant vapor intrusion pathway.
A Role for Nonapeptides and Dopamine in Nest-Building Behaviour
Hall, Z J; Healy, S D; Meddle, S L
2015-01-01
During nest building in zebra finches (Taeniopygia guttata), several regions in the social behaviour network and the dopaminergic reward system, which are two neural circuits involved in social behaviour, appear to be active in male and female nest-building finches. Because the nonapeptides, mesotocin and vasotocin and the neurotransmitter, dopamine, play important roles in avian social behaviour, we tested the hypothesis that mesotocinergic-vasotocinergic and dopaminergic neuronal populations in the social behaviour network and dopaminergic reward system, respectively, are active during nest building. We combined immunohistochemistry for Fos (an indirect marker of neuronal activity) and vasotocin, mesotocin or tyrosine hydroxylase on brain tissue from nest-building and non-nest-building male and female zebra finches and compared Fos immunoreactivity in these neuronal populations with the variation in nest-building behaviour. Fos immunoreactivity in all three types of neuronal populations increased with some aspect of nest building: (i) higher immunoreactivity in a mesotocinergic neuronal population of nest-building finches compared to controls; (ii) increased immunoreactivity in the vasotocinergic neuronal populations in relation to the amount of material picked up by nest-building males and the length of time that a male spent in the nest with his mate; and (iii) increased immunoreactivity in a dopaminergic neuronal population in relation to the length of time that a male nest-building finch spent in the nest with his mate. Taken together, these findings provide evidence for a role of the mesotocinergic-vasotocinergic and dopaminergic systems in avian nest building. PMID:25514990
NASA Astrophysics Data System (ADS)
Williams, G. T.; Kennedy, B. M.; Wilson, T. M.; Fitzgerald, R. H.; Tsunematsu, K.; Teissier, A.
2017-09-01
Recent casualties in volcanic eruptions due to trauma from blocks and bombs necessitate more rigorous, ballistic specific risk assessment. Quantitative assessments are limited by a lack of experimental and field data on the vulnerability of buildings to ballistic hazards. An improved, quantitative understanding of building vulnerability to ballistic impacts is required for informing appropriate life safety actions and other risk reduction strategies. We assessed ballistic impacts to buildings from eruptions at Usu Volcano and Mt. Ontake in Japan and compiled available impact data from eruptions elsewhere to identify common damage patterns from ballistic impacts to buildings. We additionally completed a series of cannon experiments which simulate ballistic block impacts to building claddings to investigate their performance over a range of ballistic projectile velocities, masses and energies. Our experiments provide new insights by quantifying (1) the hazard associated with post-impact shrapnel from building and rock fragments; (2) the effect of impact obliquity on damage; and (3) the additional impact resistance buildings possess when claddings are struck in areas directly supported by framing components. This was not well identified in previous work which may have underestimated building vulnerability to ballistic hazards. To improve assessment of building vulnerability to ballistics, we use our experimental and field data to develop quantitative vulnerability models known as fragility functions. Our fragility functions and field studies show that although unreinforced buildings are highly vulnerable to large ballistics (> 20 cm diameter), they can still provide shelter, preventing death during eruptions.
NASA Astrophysics Data System (ADS)
Ilie, C. A.; Visa, I.; Duta, A.
2016-08-01
The EU legal frame imposes the Nearly Zero Energy Buildings (nZEB) status to any new public building starting with January 1st, 2019 and for any other new building starting with 2021. Basically, nZEB represents a Low Energy Building (LEB) that covers more than half of the energy demand by using renewable energy systems installed on or close to it. Thus, two steps have to be followed in developing nZEB: (1) reaching the LEB status through state- of-the art architectural and construction solutions (for the new buildings) or through refurbishing for the already existent buildings, followed by (2) implementing renewables; in Romania, over 65% of the energy demand in a building is directly linked to heating, domestic hot water (DHW), and - in certain areas - for cooling. Thus, effort should be directed to reduce the thermal energy demand to be further covered by using clean and affordable systems: solar- thermal systems, heat pumps, biomass, etc. or their hybrid combinations. Obviously this demand is influenced by the onsite climatic profile and by the building performance. An almost worst case scenario is approached in the paper, considering a community implemented in a mountain area, with cold and long winters and mild summers (Odorheiul Secuiesc city, Harghita county, Romania). Three representative types of buildings are analysed: multi-family households (in blocks of flats), single-family houses and administrative buildings. For the first two types, old and refurbished buildings were comparatively discussed.
The application, benefits and challenges of retrofitting the existing buildings
NASA Astrophysics Data System (ADS)
Khairi, Muhammad; Jaapar, Aini; Yahya, Zaharah
2017-11-01
Sustainable development has been the main topic of debate for years in some countries such as United Kingdom, United State of America and Malaysia. Depletion of natural resources, global warming, economics uncertainty and health issues are some of the reasons behind sustainable development movements, it is not just a political debate in the parliament but more towards collective works among sectors in order to minimizing the negative impact of development to the environment and other living organism. Retrofit an existing building is one of the solutions to reduce the dependency on constructing new buildings. There are huge numbers of existing building stocks that suitable to be retrofitted such as historical buildings, offices, residential, warehouse, factories, vacant buildings and other historical buildings. Therefore, the aim of this research is to provide information on the application, benefits and challenges of retrofitting an existing building. Two buildings were chosen as case studies following by site visits and observation to the buildings. The data were then compared in a table form. Primary and secondary sources were also used for this research. The application of retrofit should be promoted across the construction and conservation industries since it has significant tangible and intangible benefits. It is one of the most environmentally friendly and efficient solutions to optimize the energy performance and could also helps to extend the life of the existing building or historical buildings while ensuring optimum thermal comfort for the occupants which leads to higher productivity.
Energy in buildings: Efficiency, renewables and storage
NASA Astrophysics Data System (ADS)
Koebel, Matthias M.
2017-07-01
This lecture summary provides a short but comprehensive overview on the "energy and buildings" topic. Buildings account for roughly 40% of the global energy demands. Thus, an increased adoption of existing and upcoming materials and solutions for the building sector represents an enormous potential to reduce building related energy demands and greenhouse gas emissions. The central question is how the building envelope (insulation, fenestration, construction style, solar control) affects building energy demands. Compared to conventional insulation materials, superinsulation materials such as vacuum insulation panels and silica aerogel achieve the same thermal performance with significantly thinner insulation layers. With low-emissivity coatings and appropriate filler gasses, double and triple glazing reduce thermal losses by up to an order of magnitude compared to old single pane windows, while vacuum insulation and aerogel filled glazing could reduce these even further. Electrochromic and other switchable glazing solutions maximize solar gains during wintertime and minimize illumination demands whilst avoiding overheating in summer. Upon integration of renewable energy systems into the building energy supply, buildings can become both producers and consumers of energy. Combined with dynamic user behavior, temporal variations in the production of renewable energy require appropriate storage solutions, both thermal and electrical, and the integration of buildings into smart grids and energy district networks. The combination of these measures allows a reduction of the existing building stock by roughly a factor of three —a promising, but cost intensive way, to prepare our buildings for the energy turnaround.
Energy savings potential from improved building controls for the US commercial building sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fernandez, Nick; Katipamula, Srinivas; Wang, Weimin
The U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) sponsored a study to determine the potential national savings achievable in the commercial building sector through widespread deployment of best practice controls, elimination of system and component faults, and use of better sensing. Detailed characterization of potential savings was one source of input to set research, development, and deployment (RD&D) goals in the field of building sensors and controls. DOE’s building energy simulation software, EnergyPlus, was employed to estimate the potential savings from 34 measures in 9 building types and across 16 climates representing almost 57% of commercial building sectormore » energy consumption. In addition to estimating savings from individual measures, three packages of measures were created to estimate savings from the packages. These packages represented an 1) efficient building, 2) typical building, and 3) inefficient building. To scale the results from individual measures or a package to the national scale, building weights by building type and climate locations from the Energy Information Administration’s 2012 Commercial Building Energy Consumption Survey (CBECS) were used. The results showed significant potential for energy savings across all building types and climates. The total site potential savings from individual measures by building type and climate location ranged between 0% and 25%. The total site potential savings by building type aggregated across all climates (using the CBECS building weights) for each measure varied between 0% and 16%. The total site potential savings aggregated across all building types and climates for each measure varied between 0% and 11%. Some individual measures had negative savings because correcting underlying operational problems (e.g., inadequate ventilation) resulted in increased energy consumption. When combined into packages, the overall national savings potential is estimated to be 29%; seven of the nine building types were in the range of 23 to 29% and two exceeded 40%. The total potential national site savings in for each building type ranged between 95x106 GJ (0.09 Quadrillion British thermal units [Quads]; Large Hotels) to 222x106 GJ (0.21 Quads; Large Office, Hospital Administrative areas, and College/University), resulting in total site savings of 1,393x106 GJ (1.32 Quads) when the three packages are applied to the U.S. commercial buildings stock. Using the source (or primary) energy conversion factors of 1.05 for natural gas and 3.14 for electricity resulted in an approximate potential primary energy savings of 2,912x106 GJ (2.76 Quads), which would be 15% of the sector’s 2015 use of approximately 18,991x106 GJ (18 Quads). Extrapolating the results for other building types not analyzed as part of this study, the primary energy savings could be in the range of 4,220x106 GJ to 5,275x106 GJ (4 to 5 Quads). If this savings potential is realized, it would be equivalent to not combusting 180 to 230 million tons of coal or reducing the energy impacts, at today’s energy intensities, of the per capita consumption of 12 to 15 million people in the U.S. To realize most of this potential savings, many gaps can be addressed through RD&D, as recommended in this paper.« less
Guidelines for Building Science Education
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metzger, Cheryn E.; Rashkin, Samuel; Huelman, Pat
The U.S. Department of Energy’s (DOE) residential research and demonstration program, Building America, has triumphed through 20 years of innovation. Partnering with researchers, builders, remodelers, and manufacturers to develop innovative processes like advanced framing and ventilation standards, Building America has proven an energy efficient design can be more cost effective, healthy, and durable than a standard house. As Building America partners continue to achieve their stretch goals, they have found that the barrier to true market transformation for high performance homes is the limited knowledge-base of the professionals working in the building industry. With dozens of professionals taking part inmore » the design and execution of building and selling homes, each person should have basic building science knowledge relevant to their role, and an understanding of how various home components interface with each other. Instead, our industry typically experiences a fragmented approach to home building and design. After obtaining important input from stakeholders at the Building Science Education Kick-Off Meeting, DOE created a building science education strategy addressing education issues preventing the widespread adoption of high performance homes. This strategy targets the next generation and provides valuable guidance for the current workforce. The initiative includes: • Race to Zero Student Design Competition: Engages universities and provides students who will be the next generation of architects, engineers, construction managers and entrepreneurs with the necessary skills and experience they need to begin careers in clean energy and generate creative solutions to real world problems. • Building Science to Sales Translator: Simplifies building science into compelling sales language and tools to sell high performance homes to their customers. • Building Science Education Guidance: Brings together industry and academia to solve problems related to building science education. This report summarizes the steps DOE has taken to develop guidance for building science education and outlines a path forward towards creating real change for an industry in need. The Guidelines for Building Science Education outlined in Appendix A of this report have been developed for external stakeholders to use to certify that their programs are incorporating the most important aspects of building science at the most appropriate proficiency level for their role. The guidelines are intended to be used primarily by training organizations, universities, and certification bodies. Each guideline can be printed or saved as a stand-alone document for ease-of-use by the respective stakeholder group. In 2015, DOE, with leadership from Pacific Northwest National Laboratory (PNNL), is launching a multi-year campaign to promote the adoption of the Guidelines for Building Science Education in a variety of training settings.« less
A spatiotemporal multi-hazard exposure assessment based on property data
NASA Astrophysics Data System (ADS)
Fuchs, S.; Keiler, M.; Zischg, A.
2015-09-01
The paper presents a nation-wide spatially explicit object-based assessment of buildings and citizens exposed to natural hazards in Austria, including river flooding, torrential flooding, and snow avalanches. The assessment was based on two different data sets, (a) hazard information providing input to the exposure of elements at risk, and (b) information on the building stock combined from different spatial data available on the national level. Hazard information was compiled from two different sources. For torrential flooding and snow avalanches available local-scale hazard maps were used, and for river flooding the results of the countrywide flood modelling eHORA were available. Information on the building stock contained information on the location and size of each building, as well as on the building category and the construction period. Additional information related to the individual floors, such as their height and net area, main purpose and configuration, was included for each property. Moreover, this data set has an interface to the population register and allowed, therefore, for retrieving the number of primary residents for each building. With the exception of sacral buildings, an economic module was used to compute the monetary value of buildings using (a) the information of the building register such as building type, number of storeys and utilisation, and (b) regionally averaged construction costs. It is shown that the repeatedly stated assumption of increasing exposure due to continued population growth and related increase in assets has to be carefully evaluated by the local development of building stock. While some regions have shown a clearly above-average increase in assets, other regions were characterised by a below-average development. This mirrors the topography of the country, but also the different economic activities. While hotels and hostels are extraordinarily prone to torrential flooding, commercial buildings as well as buildings used for recreational purposes are considerably exposed to river flooding. Residential buildings have shown an average exposure, compared to the number of buildings of this type in the overall building stock. In sum, around 5 % of all buildings are exposed to torrential flooding, and around 9 % to river flooding, with around 1 % of the buildings stock being multi-exposed. The temporal assessment of exposure has shown considerable differences in the dynamics of exposure to different hazard categories in comparison to the overall property stock. In conclusion, the presented object-based assessment is an important and suitable tool for nation-wide exposure assessment and may be used in operational risk management.
9. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, ...
9. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, 1958 PALLADIAN WINDOW AT NORTH END OF CENTRAL HALL. 10. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, 1958 CENTRAL VIEW OF DOUBLE PARLORS FROM SOUTHWEST PARLOR TOWARD NORTHWEST PARLOR. 11. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, 1958 WALLPAPER IN SOUTHWEST PARLOR. 12. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, 1958 FIREPLACE IN SOUTHWEST PARLOR. 13. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, 1958 WINDOW IN SOUTHWEST PARLOR. 14. Historic American Buildings Survey, Laurence E. Tilley, Photographer April, 1958 DETAIL OF WALLPAPER AND WOODWORK IN ... - Eliza Ward House, 2 George Street, Providence, Providence County, RI