Sample records for building code standards

  1. National Cost-effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, Brian; Halverson, Mark A.; Myer, Michael

    Pacific Northwest National Laboratory (PNNL) completed this project for the U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP). DOE’s BECP supports upgrading building energy codes and standards, and the states’ adoption, implementation, and enforcement of upgraded codes and standards. Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. Continuous improvement of building energy efficiency is achieved by periodically upgrading energy codes and standards. Ensuring that changes in the code that may alter costs (for building components,more » initial purchase and installation, replacement, maintenance and energy) are cost-effective encourages their acceptance and implementation. ANSI/ASHRAE/IESNA Standard 90.1 is the energy standard for commercial and multi-family residential buildings over three floors.« less

  2. Cost-effectiveness of ASHRAE Standard 90.1-2010 Compared to ASHRAE Standard 90.1-2007

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, Brian A.; Halverson, Mark A.; Myer, Michael

    Pacific Northwest National Laboratory (PNNL) completed this project for the U.S. Department of Energy’s (DOE’s) Building Energy Codes Program (BECP). DOE’s BECP supports upgrading building energy codes and standards, and the states’ adoption, implementation, and enforcement of upgraded codes and standards. Building energy codes and standards set minimum requirements for energy-efficient design and construction for new and renovated buildings, and impact energy use and greenhouse gas emissions for the life of buildings. Continuous improvement of building energy efficiency is achieved by periodically upgrading energy codes and standards. Ensuring that changes in the code that may alter costs (for building components,more » initial purchase and installation, replacement, maintenance and energy) are cost-effective encourages their acceptance and implementation. ANSI/ASHRAE/IESNA Standard 90.1 is the energy standard for commercial and multi-family residential buildings over three floors.« less

  3. 24 CFR 92.251 - Property standards.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., as applicable, one of three model codes: Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI); or the Council of American Building Officials (CABO) one or two...) Housing that is constructed or rehabilitated with HOME funds must meet all applicable local codes...

  4. 24 CFR 92.251 - Property standards.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., as applicable, one of three model codes: Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI); or the Council of American Building Officials (CABO) one or two...) Housing that is constructed or rehabilitated with HOME funds must meet all applicable local codes...

  5. 24 CFR 92.251 - Property standards.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ..., as applicable, one of three model codes: Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI); or the Council of American Building Officials (CABO) one or two...) Housing that is constructed or rehabilitated with HOME funds must meet all applicable local codes...

  6. 24 CFR 92.251 - Property standards.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ..., as applicable, one of three model codes: Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI); or the Council of American Building Officials (CABO) one or two...) Housing that is constructed or rehabilitated with HOME funds must meet all applicable local codes...

  7. Building Standards and Codes for Energy Conservation

    ERIC Educational Resources Information Center

    Gross, James G.; Pierlert, James H.

    1977-01-01

    Current activity intended to lead to energy conservation measures in building codes and standards is reviewed by members of the Office of Building Standards and Codes Services of the National Bureau of Standards. For journal availability see HE 508 931. (LBH)

  8. 75 FR 19944 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-16

    ... for Residential Construction in High Wind Areas. ICC 700: National Green Building Standard. The... Codes and Standards that are comprehensive, coordinated, and necessary to regulate the built environment... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  9. 38 CFR 39.63 - Architectural design standards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 5000, Building Construction and Safety Code, and the 2002 edition of the National Electrical Code, NFPA... 5000, Building Construction and Safety Code. Where the adopted codes state conflicting requirements... the standards set forth in this section, all applicable local and State building codes and regulations...

  10. 38 CFR 39.63 - Architectural design standards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 5000, Building Construction and Safety Code, and the 2002 edition of the National Electrical Code, NFPA... 5000, Building Construction and Safety Code. Where the adopted codes state conflicting requirements... the standards set forth in this section, all applicable local and State building codes and regulations...

  11. 38 CFR 39.63 - Architectural design standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 5000, Building Construction and Safety Code, and the 2002 edition of the National Electrical Code, NFPA... 5000, Building Construction and Safety Code. Where the adopted codes state conflicting requirements... the standards set forth in this section, all applicable local and State building codes and regulations...

  12. 25 CFR 900.125 - What shall a construction contract proposal contain?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... tribal building codes and engineering standards; (4) Structural integrity; (5) Accountability of funds..., standards and methods (including national, regional, state, or tribal building codes or construction... methods (including national, regional, state, or tribal building codes or construction industry standards...

  13. 25 CFR 900.125 - What shall a construction contract proposal contain?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... tribal building codes and engineering standards; (4) Structural integrity; (5) Accountability of funds..., standards and methods (including national, regional, state, or tribal building codes or construction... methods (including national, regional, state, or tribal building codes or construction industry standards...

  14. 25 CFR 900.125 - What shall a construction contract proposal contain?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... tribal building codes and engineering standards; (4) Structural integrity; (5) Accountability of funds..., standards and methods (including national, regional, state, or tribal building codes or construction... methods (including national, regional, state, or tribal building codes or construction industry standards...

  15. 25 CFR 900.125 - What shall a construction contract proposal contain?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... tribal building codes and engineering standards; (4) Structural integrity; (5) Accountability of funds..., standards and methods (including national, regional, state, or tribal building codes or construction... methods (including national, regional, state, or tribal building codes or construction industry standards...

  16. 25 CFR 900.125 - What shall a construction contract proposal contain?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... tribal building codes and engineering standards; (4) Structural integrity; (5) Accountability of funds..., standards and methods (including national, regional, state, or tribal building codes or construction... methods (including national, regional, state, or tribal building codes or construction industry standards...

  17. 78 FR 18321 - International Code Council: The Update Process for the International Codes and Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-26

    ... for Residential Construction in High Wind Regions. ICC 700: National Green Building Standard The..., coordinated, and necessary to regulate the built environment. Federal agencies frequently use these codes and... International Codes and Standards consist of the following: ICC Codes International Building Code. International...

  18. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  19. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  20. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  1. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Seismic Regulation for New Buildings. (b) Each of the following model codes or standards provides a level...) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code... buildings. 1792.103 Section 1792.103 Agriculture Regulations of the Department of Agriculture (Continued...

  2. Through the Past Decade: How Advanced Energy Design Guides have influenced the Design Industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bing; Athalye, Rahul A.

    Advanced Energy Design Guides (AEDGs) were originally developed intended to provide a simple approach to building professionals seeking energy efficient building designs better than ASHRAE Standard 90.1. Since its first book was released in 2004, the AEDG series provided inspiration for the design industry and were seen by designers as a starting point for buildings that wished to go beyond minimum codes and standards. In addition, U.S. Department of Energy’s successful Commercial Building Partnerships (CBP) program leveraged many of the recommendations from the AEDGs to achieve 50% energy savings over ASHRAE Standard 90.1-2004 for prototypical designs of large commercial entitiesmore » in the retail, banking and lodging sectors. Low-energy technologies and strategies developed during the CBP process have been applied by commercial partners throughout their national portfolio of buildings. Later, the AEDGs served as the perfect platform for both Standard 90.1 and ASHRAE’s high performance buildings standard, Standard 189.1. What was high performance a few years ago, however, has become minimum code today. Indeed, most of the prescriptive envelope component requirements in ASHRAE Standard 90.1-2013 are values recommended in the 50% AEDGs several years ago. Similarly, AEDG strategies and recommendations have penetrated the lighting and HVAC sections of both Standard 189.1 and Standard 90.1. Finally, as we look to the future of codes and standards, the AEDGs are serving as a blueprint for how minimum code requirements could be expressed. By customizing codes to specific building types, design strategies tailored for individual buildings could be prescribed as minimum code, just like in the AEDGs. This paper describes the impact that AEDGs have had over the last decade on the design industry and how they continue to influence the future of codes and Standards. From design professionals to code officials, everyone in the building industry has been affected by the AEDGs.« less

  3. 24 CFR 941.203 - Design and construction standards.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... national building code, such as Uniform Building Code, Council of American Building Officials Code, or Building Officials Conference of America Code; (2) Applicable State and local laws, codes, ordinances, and... intended to serve. Building design and construction shall strive to encourage in residents a proprietary...

  4. 24 CFR 941.203 - Design and construction standards.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... national building code, such as Uniform Building Code, Council of American Building Officials Code, or Building Officials Conference of America Code; (2) Applicable State and local laws, codes, ordinances, and... intended to serve. Building design and construction shall strive to encourage in residents a proprietary...

  5. 41 CFR 128-1.8005 - Seismic safety standards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...

  6. 41 CFR 128-1.8005 - Seismic safety standards.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...

  7. 41 CFR 128-1.8005 - Seismic safety standards.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...

  8. 41 CFR 128-1.8005 - Seismic safety standards.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the model building codes that the Interagency Committee on Seismic Safety in Construction (ICSSC...) Uniform Building Code (UBC); (2) The 1992 Supplement to the Building Officials and Code Administrators International (BOCA) National Building Code (NBC); and (3) The 1992 Amendments to the Southern Building Code...

  9. 12 CFR 1807.503 - Project completion.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...

  10. 12 CFR 1807.503 - Project completion.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...

  11. 12 CFR 1807.503 - Project completion.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...

  12. 12 CFR 1807.503 - Project completion.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... applicable: One of three model codes (Uniform Building Code (ICBO), National Building Code (BOCA), Standard (Southern) Building Code (SBCCI)); or the Council of American Building Officials (CABO) one or two family... must meet the current edition of the Model Energy Code published by the Council of American Building...

  13. 24 CFR 200.926 - Minimum property standards for one and two family dwellings.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... property is to be located. (c) Standard for evaluating local or state building codes. The Secretary shall compare a local building code submitted under paragraph (d) of this section or a State code to the list of... each area and subarea on the list. (2) A State or local building code will be partially accepted if it...

  14. 24 CFR 200.926 - Minimum property standards for one and two family dwellings.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... property is to be located. (c) Standard for evaluating local or state building codes. The Secretary shall compare a local building code submitted under paragraph (d) of this section or a State code to the list of... each area and subarea on the list. (2) A State or local building code will be partially accepted if it...

  15. 24 CFR 200.926 - Minimum property standards for one and two family dwellings.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... property is to be located. (c) Standard for evaluating local or state building codes. The Secretary shall compare a local building code submitted under paragraph (d) of this section or a State code to the list of... each area and subarea on the list. (2) A State or local building code will be partially accepted if it...

  16. Alternative Formats to Achieve More Efficient Energy Codes for Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Rosenberg, Michael I.; Halverson, Mark A.

    2013-01-26

    This paper identifies and examines several formats or structures that could be used to create the next generation of more efficient energy codes and standards for commercial buildings. Pacific Northwest National Laboratory (PNNL) is funded by the U.S. Department of Energy’s Building Energy Codes Program (BECP) to provide technical support to the development of ANSI/ASHRAE/IES Standard 90.1. While the majority of PNNL’s ASHRAE Standard 90.1 support focuses on developing and evaluating new requirements, a portion of its work involves consideration of the format of energy standards. In its current working plan, the ASHRAE 90.1 committee has approved an energy goalmore » of 50% improvement in Standard 90.1-2013 relative to Standard 90.1-2004, and will likely be considering higher improvement targets for future versions of the standard. To cost-effectively achieve the 50% goal in manner that can gain stakeholder consensus, formats other than prescriptive must be considered. Alternative formats that include reducing the reliance on prescriptive requirements may make it easier to achieve these aggressive efficiency levels in new codes and standards. The focus on energy code and standard formats is meant to explore approaches to presenting the criteria that will foster compliance, enhance verification, and stimulate innovation while saving energy in buildings. New formats may also make it easier for building designers and owners to design and build the levels of efficiency called for in the new codes and standards. This paper examines a number of potential formats and structures, including prescriptive, performance-based (with sub-formats of performance equivalency and performance targets), capacity constraint-based, and outcome-based. The paper also discusses the pros and cons of each format from the viewpoint of code users and of code enforcers.« less

  17. Building codes : obstacle or opportunity?

    Treesearch

    Alberto Goetzl; David B. McKeever

    1999-01-01

    Building codes are critically important in the use of wood products for construction. The codes contain regulations that are prescriptive or performance related for various kinds of buildings and construction types. A prescriptive standard might dictate that a particular type of material be used in a given application. A performance standard requires that a particular...

  18. Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.

    2016-02-16

    Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI)more » less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.« less

  19. Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method - Rev.1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.

    2016-03-01

    Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI)more » less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.« less

  20. 25 CFR 256.10 - When do I qualify for Category C assistance?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... living The dwelling cannot be brought up to applicable building code standards and to standard housing... applicable building code standards and to standard housing condition for $35,000 or less. You do not own a...

  1. 25 CFR 256.10 - When do I qualify for Category C assistance?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... The dwelling cannot be brought up to applicable building code standards and to standard housing... applicable building code standards and to standard housing condition for $35,000 or less. You do not own a...

  2. 25 CFR 256.10 - When do I qualify for Category C assistance?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... living The dwelling cannot be brought up to applicable building code standards and to standard housing... applicable building code standards and to standard housing condition for $35,000 or less. You do not own a...

  3. 25 CFR 256.10 - When do I qualify for Category C assistance?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... living The dwelling cannot be brought up to applicable building code standards and to standard housing... applicable building code standards and to standard housing condition for $35,000 or less. You do not own a...

  4. 25 CFR 256.10 - When do I qualify for Category C assistance?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... living The dwelling cannot be brought up to applicable building code standards and to standard housing... applicable building code standards and to standard housing condition for $35,000 or less. You do not own a...

  5. Building Energy Codes: Policy Overview and Good Practices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cox, Sadie

    2016-02-19

    Globally, 32% of total final energy consumption is attributed to the building sector. To reduce energy consumption, energy codes set minimum energy efficiency standards for the building sector. With effective implementation, building energy codes can support energy cost savings and complementary benefits associated with electricity reliability, air quality improvement, greenhouse gas emission reduction, increased comfort, and economic and social development. This policy brief seeks to support building code policymakers and implementers in designing effective building code programs.

  6. 42 CFR 137.328 - Must a construction project proposal incorporate provisions of Federal construction guidelines...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., the Self-Governance Tribe and the Secretary must agree upon and specify appropriate building codes and...-Governance Tribe in the preparation of its construction project proposal. If Tribal construction codes and standards (including national, regional, State, or Tribal building codes or construction industry standards...

  7. 42 CFR 137.328 - Must a construction project proposal incorporate provisions of Federal construction guidelines...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., the Self-Governance Tribe and the Secretary must agree upon and specify appropriate building codes and...-Governance Tribe in the preparation of its construction project proposal. If Tribal construction codes and standards (including national, regional, State, or Tribal building codes or construction industry standards...

  8. 42 CFR 137.328 - Must a construction project proposal incorporate provisions of Federal construction guidelines...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., the Self-Governance Tribe and the Secretary must agree upon and specify appropriate building codes and...-Governance Tribe in the preparation of its construction project proposal. If Tribal construction codes and standards (including national, regional, State, or Tribal building codes or construction industry standards...

  9. 42 CFR 137.328 - Must a construction project proposal incorporate provisions of Federal construction guidelines...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., the Self-Governance Tribe and the Secretary must agree upon and specify appropriate building codes and...-Governance Tribe in the preparation of its construction project proposal. If Tribal construction codes and standards (including national, regional, State, or Tribal building codes or construction industry standards...

  10. 42 CFR 137.328 - Must a construction project proposal incorporate provisions of Federal construction guidelines...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., the Self-Governance Tribe and the Secretary must agree upon and specify appropriate building codes and...-Governance Tribe in the preparation of its construction project proposal. If Tribal construction codes and standards (including national, regional, State, or Tribal building codes or construction industry standards...

  11. The Influence of Building Codes on Recreation Facility Design.

    ERIC Educational Resources Information Center

    Morrison, Thomas A.

    1989-01-01

    Implications of building codes upon design and construction of recreation facilities are investigated (national building codes, recreation facility standards, and misperceptions of design requirements). Recreation professionals can influence architectural designers to correct past deficiencies, but they must understand architectural and…

  12. Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Bing; Zhang, Jian; Chen, Yan

    This study was conducted by the Pacific Northwest National Laboratory (PNNL) in support of the stretch energy code development led by the New York State Energy Research and Development Authority (NYSERDA). In 2017 NYSERDA developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code (hereinafter referred to as “NYStretch-Energy”). NYStretch-Energy is intended as a model energy code for statewide voluntary adoption that anticipates other code advancements culminating in the goal of a statewide Net Zero Energy Code by 2028. Since then, NYSERDA continues to develop the NYStretch-Energy Code 2018 edition. To support the effort,more » PNNL conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code (2018) in New York. The focus of this project is the 20% improvement over existing commercial model energy codes. A key requirement of the proposed stretch code is that it be ‘adoptable’ as an energy code, meaning that it must align with current code scope and limitations, and primarily impact building components that are currently regulated by local building departments. It is largely limited to prescriptive measures, which are what most building departments and design projects are most familiar with. This report describes a set of energy-efficiency measures (EEMs) that demonstrate 20% energy savings over ANSI/ASHRAE/IES Standard 90.1-2013 (ASHRAE 2013) across a broad range of commercial building types and all three climate zones in New York. In collaboration with New Building Institute, the EEMs were developed from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the on-going code development process. PNNL analyzed these measures using whole building energy models for selected prototype commercial buildings and multifamily buildings representing buildings in New York. Section 2 of this report describes the analysis methodology, including the building types and construction area weights update for this analysis, the baseline, and the method to conduct the energy saving analysis. Section 3 provides detailed specifications of the EEMs and bundles. Section 4 summarizes the results of individual EEMs and EEM bundles by building type, energy end-use and climate zone. Appendix A documents detailed descriptions of the selected prototype buildings. Appendix B provides energy end-use breakdown results by building type for both the baseline code and stretch code in all climate zones.« less

  13. 38 CFR 39.63 - Architectural design standards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Association Life Safety Code and Errata (NFPA 101), the 2003 edition of the NFPA 5000, Building Construction... section, all applicable local and State building codes and regulations must be observed. In areas not subject to local or State building codes, the recommendations contained in the 2003 edition of the NFPA...

  14. Implementation of Energy Code Controls Requirements in New Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Hatten, Mike

    Most state energy codes in the United States are based on one of two national model codes; ANSI/ASHRAE/IES 90.1 (Standard 90.1) or the International Code Council (ICC) International Energy Conservation Code (IECC). Since 2004, covering the last four cycles of Standard 90.1 updates, about 30% of all new requirements have been related to building controls. These requirements can be difficult to implement and verification is beyond the expertise of most building code officials, yet the assumption in studies that measure the savings from energy codes is that they are implemented and working correctly. The objective of the current research ismore » to evaluate the degree to which high impact controls requirements included in commercial energy codes are properly designed, commissioned and implemented in new buildings. This study also evaluates the degree to which these control requirements are realizing their savings potential. This was done using a three-step process. The first step involved interviewing commissioning agents to get a better understanding of their activities as they relate to energy code required controls measures. The second involved field audits of a sample of commercial buildings to determine whether the code required control measures are being designed, commissioned and correctly implemented and functioning in new buildings. The third step includes compilation and analysis of the information gather during the first two steps. Information gathered during these activities could be valuable to code developers, energy planners, designers, building owners, and building officials.« less

  15. Building Codes and Regulations.

    ERIC Educational Resources Information Center

    Fisher, John L.

    The hazard of fire is of great concern to libraries due to combustible books and new plastics used in construction and interiors. Building codes and standards can offer architects and planners guidelines to follow but these standards should be closely monitored, updated, and researched for fire prevention. (DS)

  16. 26 CFR 1.42-5 - Monitoring compliance with low-income housing credit requirements.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... be required to retain the original local health, safety, or building code violation reports or... account local health, safety, and building codes (or other habitability standards), and the State or local government unit responsible for making local health, safety, or building code inspections did not issue a...

  17. 26 CFR 1.42-5 - Monitoring compliance with low-income housing credit requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... be required to retain the original local health, safety, or building code violation reports or... account local health, safety, and building codes (or other habitability standards), and the State or local government unit responsible for making local health, safety, or building code inspections did not issue a...

  18. 44 CFR 206.400 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... standards of safety, decency, and sanitation and in conformity with applicable codes, specifications and standards. (b) Applicable codes, specifications, and standards shall include any disaster resistant building code that meets the minimum requirements of the National Flood Insurance Program (NFIP) as well as...

  19. 44 CFR 206.400 - General.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... standards of safety, decency, and sanitation and in conformity with applicable codes, specifications and standards. (b) Applicable codes, specifications, and standards shall include any disaster resistant building code that meets the minimum requirements of the National Flood Insurance Program (NFIP) as well as...

  20. 44 CFR 206.400 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... standards of safety, decency, and sanitation and in conformity with applicable codes, specifications and standards. (b) Applicable codes, specifications, and standards shall include any disaster resistant building code that meets the minimum requirements of the National Flood Insurance Program (NFIP) as well as...

  1. 44 CFR 206.400 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... standards of safety, decency, and sanitation and in conformity with applicable codes, specifications and standards. (b) Applicable codes, specifications, and standards shall include any disaster resistant building code that meets the minimum requirements of the National Flood Insurance Program (NFIP) as well as...

  2. 44 CFR 206.400 - General.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... standards of safety, decency, and sanitation and in conformity with applicable codes, specifications and standards. (b) Applicable codes, specifications, and standards shall include any disaster resistant building code that meets the minimum requirements of the National Flood Insurance Program (NFIP) as well as...

  3. 41 CFR 102-80.80 - With what general accident and fire prevention policy must Federal agencies comply?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... maximum extent feasible, comply with one of the nationally recognized model building codes and with other nationally-recognized codes in their construction or alteration of each building in accordance with 40 U.S.C. 3312; and (f) Use the applicable national codes and standards as a guide for their building operations...

  4. 41 CFR 102-80.80 - With what general accident and fire prevention policy must Federal agencies comply?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... maximum extent feasible, comply with one of the nationally recognized model building codes and with other nationally-recognized codes in their construction or alteration of each building in accordance with 40 U.S.C. 3312; and (f) Use the applicable national codes and standards as a guide for their building operations...

  5. 41 CFR 102-80.80 - With what general accident and fire prevention policy must Federal agencies comply?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... maximum extent feasible, comply with one of the nationally recognized model building codes and with other nationally-recognized codes in their construction or alteration of each building in accordance with 40 U.S.C. 3312; and (f) Use the applicable national codes and standards as a guide for their building operations...

  6. 41 CFR 102-80.80 - With what general accident and fire prevention policy must Federal agencies comply?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... maximum extent feasible, comply with one of the nationally recognized model building codes and with other nationally-recognized codes in their construction or alteration of each building in accordance with 40 U.S.C. 3312; and (f) Use the applicable national codes and standards as a guide for their building operations...

  7. Innovation and Standardization in School Building: A Proposal for the National Code in Italy.

    ERIC Educational Resources Information Center

    Ridolfi, Giuseppe

    This document discusses the University of Florence's experience and concepts as it developed the research to define a proposal for designing a new national school building code. Section 1 examines the current school building code and the Italian Reform Process in Education between 1960 and 2000. Section 2 details and explains the new school…

  8. Technical Support Document for Version 3.4.0 of the COMcheck Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan

    2007-09-14

    COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards.« less

  9. Energy and Energy Cost Savings Analysis of the 2015 IECC for Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jian; Xie, YuLong; Athalye, Rahul A.

    As required by statute (42 USC 6833), DOE recently issued a determination that ANSI/ASHRAE/IES Standard 90.1-2013 would achieve greater energy efficiency in buildings subject to the code compared to the 2010 edition of the standard. Pacific Northwest National Laboratory (PNNL) conducted an energy savings analysis for Standard 90.1-2013 in support of its determination . While Standard 90.1 is the model energy standard for commercial and multi-family residential buildings over three floors (42 USC 6833), many states have historically adopted the International Energy Conservation Code (IECC) for both residential and commercial buildings. This report provides an assessment as to whether buildingsmore » constructed to the commercial energy efficiency provisions of the 2015 IECC would save energy and energy costs as compared to the 2012 IECC. PNNL also compared the energy performance of the 2015 IECC with the corresponding Standard 90.1-2013. The goal of this analysis is to help states and local jurisdictions make informed decisions regarding model code adoption.« less

  10. Energy Building Regulations: The Effect of the Federal Performance Standards on Building Code Administration and the Conservation of Energy in New Buildings.

    ERIC Educational Resources Information Center

    Kopper, William D.

    1980-01-01

    Explores the changes in the administration and enforcement of building regulations that will be engendered by the proposed federal energy building standards. Also evaluates the effectiveness of those standards in meeting congressional intent. Available from U.C. Davis Law Review, School of Law, Martin Luther King Jr. Hall, University of…

  11. Implementing energy standards for motors and buildings in the Philippines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiel, S.; Busch, J.; Sanchez, C.

    1998-07-01

    The Philippines' master plan for energy makes cornerstones of energy standards for appliances, buildings, and motors in their energy efficiency effort. Significant progress has been made in implementing appliance standards for some products, but has lagged for others. This has been partly because the resources allocated have dictated a cautious deliberate approach. Products where there has been a lack of information about the respective markets have received lowest priority. Motors fall in this latter category. In their development of building codes, the Philippine government has also taken a cautious deliberate approach and is just now attending to the compliance ofmore » a commercial building energy performance standard that was enacted into law in 1994. This paper describes the results of recent new buildings and motor market assessments carried out in the Philippines, a survey of building energy code implementation in other countries, and how these products are being used to further implementation of energy standards in the Philippines. Lessons for other countries are drawn from this experience.« less

  12. Technical Support Document for Version 3.9.0 of the COMcheck Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan

    2011-09-01

    COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC are no longer included, but those sections remain in this document for reference purposes.« less

  13. Technical Support Document for Version 3.9.1 of the COMcheck Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan

    2012-09-01

    COMcheck provides an optional way to demonstrate compliance with commercial and high-rise residential building energy codes. Commercial buildings include all use groups except single family and multifamily not over three stories in height. COMcheck was originally based on ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989) requirements and is intended for use with various codes based on Standard 90.1, including the Codification of ASHRAE/IES Standard 90.1-1989 (90.1-1989 Code) (ASHRAE 1989a, 1993b) and ASHRAE/IESNA Standard 90.1-1999 (Standard 90.1-1999). This includes jurisdictions that have adopted the 90.1-1989 Code, Standard 90.1-1989, Standard 90.1-1999, or their own code based on one of these. We view Standard 90.1-1989more » and the 90.1-1989 Code as having equivalent technical content and have used both as source documents in developing COMcheck. This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards. Beginning with COMcheck version 3.8.0, support for 90.1-1989, 90.1-1999, and the 1998 IECC and version 3.9.0 support for 2000 and 2001 IECC are no longer included, but those sections remain in this document for reference purposes.« less

  14. Standardized reporting using CODES (Crash Outcome Data Evaluation System)

    DOT National Transportation Integrated Search

    1999-12-01

    While CODES projects have expanded to 25 states, there is no standardized reporting of the outcome measures that are available with linked data. This paper describes our efforts to build a standard format for reporting these outcomes. This format is ...

  15. 10 CFR 420.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Planning Organization means that organization required by the Department of Transportation, and designated... planning provisions in a Standard Metropolitan Statistical Area. Model Energy Code, 1993, including Errata, means the model building code published by the Council of American Building Officials, which is...

  16. Joint China-United States Report for Year 1 Insulation Materials and Systems Project Area Clean Energy Research Center Building Energy Efficiency (CERC-BEE)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stovall, Therese K; Biswas, Kaushik; Song, Bo

    In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications inmore » green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy efficiency and fire safety. A related issue is the degree to which new standards are adopted and enforced. In the U.S., standards are developed using a consensus process, and local government agencies are free to implement these standards or to ignore them. For example, some U.S. states are still using 2003 versions of the building efficiency standards. There is also a great variation in the degree to which the locally adopted standards are enforced in different U.S. cities and states. With a more central process in China, these issues are different, but possible impacts of variable enforcement efficacy may also exist. Therefore, current building codes in China will be compared to the current state of building fire-safety and energy-efficiency codes in the U.S. and areas for possible improvements in both countries will be explored. In particular, the focus of the applications in China will be on green buildings. The terminology of 'green buildings' has different meanings to different audiences. The U.S. research is interested in both new, green buildings, and on retrofitting existing inefficient buildings. An initial effort will be made to clarify the scope of the pertinent wall insulation systems for these applications.« less

  17. 49 CFR 41.110 - New DOT owned buildings and additions to buildings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... architect's authenticated verifications of seismic design codes, standards, and practices used in the design... for the design and construction of new DOT Federally owned buildings will ensure that each building is designed and constructed in accord with the seismic design and construction standards set out in § 41.120...

  18. Building codes: An often overlooked determinant of health.

    PubMed

    Chauvin, James; Pauls, Jake; Strobl, Linda

    2016-05-01

    Although the vast majority of the world's population spends most of their time in buildings, building codes are not often thought of as 'determinants of health'. The standards that govern the design, construction, and use of buildings affect our health, security, safety, and well-being. This is true for dwellings, schools, and universities, shopping centers, places of recreation, places of worship, health-care facilities, and workplaces. We urge proactive engagement by the global public health community in developing these codes, and in the design and implementation of health protection and health promotion activities intended to reduce the risk of injury, disability, and death, particularly when due to poor building code adoption/adaption, application, and enforcement.

  19. Building Code Compliance and Enforcement: The Experience of SanFrancisco's Residential Energy Conservation Ordinanace and California'sBuildign Standards for New Construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    1990-11-01

    As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. Because statewide codes are enforced by local officials, these problems may increase over time as energy standards change and become more complex and as other standards (eg, health and safety codes) remain a higher priority. The California Energy Commission realizes that code enforcement by itself is insufficient and expects that additional educational and technical assistance efforts (eg, manuals, training programs, and toll-free telephone lines) will ameliorate these problems.« less

  20. A comparison of IBC with 1997 UBC for modal response spectrum analysis in standard-occupancy buildings

    NASA Astrophysics Data System (ADS)

    Nahhas, Tariq M.

    2011-03-01

    This paper presents a comparison of the seismic forces generated from a Modal Response Spectrum Analysis (MRSA) by applying the provisions of two building codes, the 1997 Uniform Building Code (UBC) and the 2000-2009 International Building Code (IBC), to the most common ordinary residential buildings of standard occupancy. Considering IBC as the state of the art benchmark code, the primary concern is the safety of buildings designed using the UBC as compared to those designed using the IBC. A sample of four buildings with different layouts and heights was used for this comparison. Each of these buildings was assumed to be located at four different geographical sample locations arbitrarily selected to represent various earthquake zones on a seismic map of the USA, and was subjected to code-compliant response spectrum analyses for all sample locations and for five different soil types at each location. Response spectrum analysis was performed using the ETABS software package. For all the cases investigated, the UBC was found to be significantly more conservative than the IBC. The UBC design response spectra have higher spectral accelerations, and as a result, the response spectrum analysis provided a much higher base shear and moment in the structural members as compared to the IBC. The conclusion is that ordinary office and residential buildings designed using UBC 1997 are considered to be overdesigned, and therefore they are quite safe even according to the IBC provisions.

  1. 10 CFR 434.605 - Standard Calculation Procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...

  2. 10 CFR 434.605 - Standard Calculation Procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...

  3. 10 CFR 434.510 - Standard calculation procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...

  4. 10 CFR 434.605 - Standard Calculation Procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...

  5. 10 CFR 434.605 - Standard Calculation Procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...

  6. 10 CFR 434.510 - Standard calculation procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...

  7. 10 CFR 434.605 - Standard Calculation Procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Standard Calculation Procedure. 434.605 Section 434.605 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Compliance Alternative § 434.605 Standard Calculation...

  8. 10 CFR 434.510 - Standard calculation procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...

  9. 10 CFR 434.510 - Standard calculation procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Standard calculation procedure. 434.510 Section 434.510 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.510 Standard...

  10. BOCA BASIC BUILDING CODE. 4TH ED., 1965 AND 1967. BOCA BASIC BUILDING CODE ACCUMULATIVE SUPPLEMENT.

    ERIC Educational Resources Information Center

    Building Officials Conference of America, Inc., Chicago, IL.

    NATIONALLY RECOGNIZED STANDARDS FOR THE EVALUATION OF MINIMUM SAFE PRACTICE OR FOR DETERMINING THE PERFORMANCE OF MATERIALS OR SYSTEMS OF CONSTRUCTION HAVE BEEN COMPILED AS AN AID TO DESIGNERS AND LOCAL OFFICIALS. THE CODE PRESENTS REGULATIONS IN TERMS OF MEASURED PERFORMANCE RATHER THAN IN RIGID SPECIFICATION OF MATERIALS OR METHODS. THE AREAS…

  11. Green Building Standards

    EPA Pesticide Factsheets

    Many organizations have developed model codes or rating systems that communities may use to develop green building programs or revise building ordinances. Some of the major options are listed on this page.

  12. Mandating better buildings: a global review of building codes and prospects for improvement in the United States

    DOE PAGES

    Sun, Xiaojing; Brown, Marilyn A.; Cox, Matt; ...

    2015-03-11

    This paper provides a global overview of the design, implementation, and evolution of building energy codes. Reflecting alternative policy goals, building energy codes differ significantly across the United States, the European Union, and China. This review uncovers numerous innovative practices including greenhouse gas emissions caps per square meter of building space, energy performance certificates with retrofit recommendations, and inclusion of renewable energy to achieve “nearly zero-energy buildings”. These innovations motivated an assessment of an aggressive commercial building code applied to all US states, requiring both new construction and buildings with major modifications to comply with the latest version of themore » ASHRAE 90.1 Standards. Using the National Energy Modeling System (NEMS), we estimate that by 2035, such building codes in the United States could reduce energy for space heating, cooling, water heating and lighting in commercial buildings by 16%, 15%, 20% and 5%, respectively. Impacts on different fuels and building types, energy rates and bills as well as pollution emission reductions are also examined.« less

  13. Improving Shipbuilding Productivity Through Use of Standards

    DTIC Science & Technology

    1978-06-01

    ship- building industry. In addition to the more familiar standards (e.g. ASME Boiler and Pressure Vessel Code , IEEE-45, etc.) this will include an...will simply refer- ence valid standards as appropriate (e.g. ASME Boiler and Pressure Vessel Code ), and will hopefully work hand in hand with the

  14. City Reach Code Technical Support Document

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Athalye, Rahul A.; Chen, Yan; Zhang, Jian

    This report describes and analyzes a set of energy efficiency measures that will save 20% energy over ASHRAE Standard 90.1-2013. The measures will be used to formulate a Reach Code for cities aiming to go beyond national model energy codes. A coalition of U.S. cities together with other stakeholders wanted to facilitate the development of voluntary guidelines and standards that can be implemented in stages at the city level to improve building energy efficiency. The coalition's efforts are being supported by the U.S. Department of Energy via Pacific Northwest National Laboratory (PNNL) and in collaboration with the New Buildings Institute.

  15. 78 FR 51100 - Appliance Standards and Rulemaking Federal Advisory Committee: Notice of Open Teleconference/Webinar

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-20

    ... and Building Codes, U.S. Department of Energy (DOE), Office of Energy Efficiency and Renewable Energy... posted at http://www1.eere.energy.gov/buildings/appliance_standards/asrac.html : Update on Commercial... Energy, Building Technologies Program, Mailstop EE-2J, 1000 Independence Avenue SW., Washington, DC 20585...

  16. 78 FR 8448 - Streamlining Inspection and Warranty Requirements for Federal Housing Administration (FHA) Single...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-06

    ... jurisdiction did not already perform its own inspections for new construction, and issue building permits and... expected to be minimal. The increased quality of construction materials and the standardization of building... governments that have adopted building codes to regulate and standardize the construction of residential and...

  17. 7 CFR 1792.103 - Seismic design and construction standards for new buildings.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Structures. Copies are available from the American Society of Civil Engineers, Publications Marketing Department, 1801 Alexander Bell Drive, Reston, VA 20191-4400. E-mail: marketing@asce.org. Telephone: (800) 548-2723. Fax: (703) 295-6211. (3) 2003 International Code Council (ICC) International Building Code...

  18. Technical Options for Energy Conservation in Buildings. National Conference of States on Building Codes and Standards and National Bureau of Standards Joint Emergency Workshop on Energy Conservation in Buildings. (Washington, D.C., June 19, 1973) NBS Technical Note 789.

    ERIC Educational Resources Information Center

    National Bureau of Standards (DOC), Washington, DC. Inst. for Applied Technology.

    The purpose of this report is to provide reference material on the technical options for energy conservation in buildings. Actions pertinent to existing buildings and new buildings are considered separately. Regarding existing buildings, principal topics include summer cooling, winter heating, and other energy-related features such as insulation,…

  19. Lessons learned from new construction utility demand side management programs and their implications for implementing building energy codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wise, B.K.; Hughes, K.R.; Danko, S.L.

    1994-07-01

    This report was prepared for the US Department of Energy (DOE) Office of Codes and Standards by the Pacific Northwest Laboratory (PNL) through its Building Energy Standards Program (BESP). The purpose of this task was to identify demand-side management (DSM) strategies for new construction that utilities have adopted or developed to promote energy-efficient design and construction. PNL conducted a survey of utilities and used the information gathered to extrapolate lessons learned and to identify evolving trends in utility new-construction DSM programs. The ultimate goal of the task is to identify opportunities where states might work collaboratively with utilities to promotemore » the adoption, implementation, and enforcement of energy-efficient building energy codes.« less

  20. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.925c Model codes. (a... Plumbing Code, 1993 Edition, and the BOCA National Mechanical Code, 1993 Edition, excluding Chapter I, Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood...

  1. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVELOPMENT GENERAL INTRODUCTION TO FHA PROGRAMS Minimum Property Standards § 200.925c Model codes. (a... Plumbing Code, 1993 Edition, and the BOCA National Mechanical Code, 1993 Edition, excluding Chapter I, Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood...

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This document contains the State Building Energy Codes Status prepared by Pacific Northwest National Laboratory for the U.S. Department of Energy under Contract DE-AC06-76RL01830 and dated September 1996. The U.S. Department of Energy`s Office of Codes and Standards has developed this document to provide an information resource for individuals interested in energy efficiency of buildings and the relevant building energy codes in each state and U.S. territory. This is considered to be an evolving document and will be updated twice a year. In addition, special state updates will be issued as warranted.

  3. 7 CFR 3550.10 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ..., meets or exceeds the requirements of the recognized development standards (model building codes) for... Federally Manufactured Home Construction and Safety Standard and RHS Thermal Performance Standards. It is...

  4. 7 CFR 3550.10 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., meets or exceeds the requirements of the recognized development standards (model building codes) for... Federally Manufactured Home Construction and Safety Standard and RHS Thermal Performance Standards. It is...

  5. 7 CFR 3550.10 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., meets or exceeds the requirements of the recognized development standards (model building codes) for... Federally Manufactured Home Construction and Safety Standard and RHS Thermal Performance Standards. It is...

  6. 36 CFR 1234.20 - What rules apply if there is a conflict between NARA standards and other regulatory standards...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... regional building codes, the following rules of precedence apply: (1) Between differing levels of fire... cannot be reconciled with a requirement of this part, the local or regional code applies. (b) If any of... require documentation of the mandatory nature of the conflicting code and the inability to reconcile that...

  7. 36 CFR 1234.20 - What rules apply if there is a conflict between NARA standards and other regulatory standards...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... regional building codes, the following rules of precedence apply: (1) Between differing levels of fire... cannot be reconciled with a requirement of this part, the local or regional code applies. (b) If any of... require documentation of the mandatory nature of the conflicting code and the inability to reconcile that...

  8. 36 CFR 1234.20 - What rules apply if there is a conflict between NARA standards and other regulatory standards...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... regional building codes, the following rules of precedence apply: (1) Between differing levels of fire... cannot be reconciled with a requirement of this part, the local or regional code applies. (b) If any of... require documentation of the mandatory nature of the conflicting code and the inability to reconcile that...

  9. 36 CFR § 1234.20 - What rules apply if there is a conflict between NARA standards and other regulatory standards...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... regional building codes, the following rules of precedence apply: (1) Between differing levels of fire... cannot be reconciled with a requirement of this part, the local or regional code applies. (b) If any of... require documentation of the mandatory nature of the conflicting code and the inability to reconcile that...

  10. Increasing Flexibility in Energy Code Compliance: Performance Packages

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Philip R.; Rosenberg, Michael I.

    Energy codes and standards have provided significant increases in building efficiency over the last 38 years, since the first national energy code was published in late 1975. The most commonly used path in energy codes, the prescriptive path, appears to be reaching a point of diminishing returns. As the code matures, the prescriptive path becomes more complicated, and also more restrictive. It is likely that an approach that considers the building as an integrated system will be necessary to achieve the next real gains in building efficiency. Performance code paths are increasing in popularity; however, there remains a significant designmore » team overhead in following the performance path, especially for smaller buildings. This paper focuses on development of one alternative format, prescriptive packages. A method to develop building-specific prescriptive packages is reviewed based on a multiple runs of prototypical building models that are used to develop parametric decision analysis to determines a set of packages with equivalent energy performance. The approach is designed to be cost-effective and flexible for the design team while achieving a desired level of energy efficiency performance. A demonstration of the approach based on mid-sized office buildings with two HVAC system types is shown along with a discussion of potential applicability in the energy code process.« less

  11. Building code compliance and enforcement: The experience of San Francisco's residential energy conservation ordinance and California's building standards for new construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    1990-11-01

    As part of Lawrence Berkeley Laboratory's (LBL) technical assistance to the Sustainable City Project, compliance and enforcement activities related to local and state building codes for existing and new construction were evaluated in two case studies. The analysis of the City of San Francisco's Residential Energy Conservation Ordinance (RECO) showed that a limited, prescriptive energy conservation ordinance for existing residential construction can be enforced relatively easily with little administrative costs, and that compliance with such ordinances can be quite high. Compliance with the code was facilitated by extensive publicity, an informed public concerned with the cost of energy and knowledgeablemore » about energy efficiency, the threat of punishment (Order of Abatement), the use of private inspectors, and training workshops for City and private inspectors. The analysis of California's Title 24 Standards for new residential and commercial construction showed that enforcement of this type of code for many climate zones is more complex and requires extensive administrative support for education and training of inspectors, architects, engineers, and builders. Under this code, prescriptive and performance approaches for compliance are permitted, resulting in the demand for alternative methods of enforcement: technical assistance, plan review, field inspection, and computer analysis. In contrast to existing to construction, building design and new materials and construction practices are of critical importance in new construction, creating a need for extensive technical assistance and extensive interaction between enforcement personnel and the building community. Compliance problems associated with building design and installation did occur in both residential and nonresidential buildings. 12 refs., 5 tabs.« less

  12. Overcoming Codes and Standards Barriers to Innovations in Building Energy Efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Pamala C.; Gilbride, Theresa L.

    2015-02-15

    In this journal article, the authors discuss approaches to overcoming building code barriers to energy-efficiency innovations in home construction. Building codes have been a highly motivational force for increasing the energy efficiency of new homes in the United States in recent years. But as quickly as the codes seem to be changing, new products are coming to the market at an even more rapid pace, sometimes offering approaches and construction techniques unthought of when the current code was first proposed, which might have been several years before its adoption by various jurisdictions. Due to this delay, the codes themselves canmore » become barriers to innovations that might otherwise be helping to further increase the efficiency, comfort, health or durability of new homes. . The U.S. Department of Energy’s Building America, a program dedicated to improving the energy efficiency of America’s housing stock through research and education, is working with the U.S. housing industry through its research teams to help builders identify and remove code barriers to innovation in the home construction industry. The article addresses several approaches that builders use to achieve approval for innovative building techniques when code barriers appear to exist.« less

  13. Technology Solutions Case Study: Southern Energy Homes, First DOE Zero Energy Ready Manufactured Home

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    The country’s first Zero Energy Ready manufactured home that is certified by the U.S. Department of Energy (DOE) is up and running in Russellville, Alabama. The manufactured home was built by a partnership between Southern Energy Homes and the Advanced Residential Integrated Energy Solutions Collaborative (ARIES), which is a DOE Building America team. The effort was part of a three-home study including a standard-code manufactured home and an ENERGY STAR® manufactured home. Cooling-season results showed that the building used half the space-conditioning energy of a manufactured home built to the U.S. Department of Housing and Urban Development’s (HUD’s) Manufactured Homemore » Construction and Safety Standards. These standards are known collectively as the HUD Code, which is the building standard for all U.S. manufactured housing.« less

  14. Potential impacts of climate change on the built environment: ASHRAE climate zones, building codes and national energy efficiency

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    New, Joshua Ryan; Kumar, Jitendra; Hoffman, Forrest M.

    Statement of the Problem: ASHRAE releases updates to 90.1 “Energy Standard for Buildings except Low-Rise Residential Buildings” every three years resulting in a 3.7%-17.3% increase in energy efficiency for buildings with each release. This is adopted by or informs building codes in nations across the globe, is the National Standard for the US, and individual states elect which release year of the standard they will enforce. These codes are built upon Standard 169 “Climatic Data for Building Design Standards,” the latest 2017 release of which defines climate zones based on 8, 118 weather stations throughout the world and data frommore » the past 8-25 years. This data may not be indicative of the weather that new buildings built today, will see during their upcoming 30-120 year lifespan. Methodology & Theoretical Orientation: Using more modern, high-resolution datasets from climate satellites, IPCC climate models (PCM and HadGCM), high performance computing resources (Titan) and new capabilities for clustering and optimization the authors briefly analyzed different methods for redefining climate zones. Using bottom-up analysis of multiple meteorological variables which were the subject matter, experts selected as being important to energy consumption, rather than the heating/cooling degree days currently used. Findings: We analyzed the accuracy of redefined climate zones, compared to current climate zones and how the climate zones moved under different climate change scenarios, and quantified the accuracy of these methods on a local level, at a national scale for the US. Conclusion & Significance: There is likely to be a significant annual, national energy and cost (billions USD) savings that could be realized by adjusting climate zones to take into account anticipated trends or scenarios in regional weather patterns.« less

  15. Common Day Care Safety Renovations: Descriptions, Explanations and Cost Estimates.

    ERIC Educational Resources Information Center

    Spack, Stan

    This booklet explains some of the day care safety features specified by the new Massachusetts State Building Code (January 1, 1975) which must be met before a new day care center can be licensed. The safety features described are those which most often require renovation to meet the building code standards. Best estimates of the costs involved in…

  16. 49 CFR 602.15 - Grant requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... either State or locally adopted building codes or standards, the higher of the competing minimums would... title 49, United States Code, as well as cross-cutting requirements, including but not limited to those...

  17. 49 CFR 602.15 - Grant requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... either State or locally adopted building codes or standards, the higher of the competing minimums would... title 49, United States Code, as well as cross-cutting requirements, including but not limited to those...

  18. 49 CFR 41.119 - DOT regulated buildings.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... compliance may include the engineer's and architect's authenticated verification of seismic design codes... and additions to existing buildings will ensure that each DOT regulated building is designed and constructed in accord with seismic design and construction standards as provided by this part. (b) This...

  19. The need for standards and codes to ensure an acoustically comfortable environment in multifamily housing buildings in Mexico City

    NASA Astrophysics Data System (ADS)

    Kotasek Gonzalez, Eduardo; Rodriguez Manzo, Fausto

    2002-11-01

    It is clear that almost all kinds of buildings require protection against noise and undesirable sounds, however, there are some countries where this is not yet regulated, such is the case of Mexico. Mexico City, the biggest city in the world could also be the noisiest. This is a problem which is today being debated; in fact there is no doubt that this has an important influence on the acoustic comfort conditions of dwellings, besides the habits and culture of the inhabitants, which are very different from those in the Anglo-Saxon countries. These are all details that must be taken into account in the design of an acoustic comfort standard for buildings in cities like Mexico. In this paper we deal with this problem and it suggests some recommendations to consider in a proposed acoustic comfort standard or code to be applied in the design of multifamily housing buildings in Mexico City.

  20. P.L. 102-486, "Energy Policy Act" (1992)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2011-12-13

    Amends the Energy Conservation and Production Act to set a deadline by which each State must certify to the Secretary of Energy whether its energy efficiency standards with respect to residential and commercial building codes meet or exceed those of the Council of American Building Officials (CABO) Model Energy Code, 1992, and of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers, respectively.

  1. Building Energy Efficiency in Rural China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Yu, Sha; Song, Bo

    2014-04-01

    Rural buildings in China now account for more than half of China’s total building energy use. Forty percent of the floorspace in China is in rural villages and towns. Most of these buildings are very energy inefficient, and may struggle to meet basic needs. They are cold in the winter, and often experience indoor air pollution from fuel use. The Chinese government plans to adopt a voluntary building energy code, or design standard, for rural homes. The goal is to build on China’s success with codes in urban areas to improve efficiency and comfort in rural homes. The Chinese governmentmore » recognizes rural buildings represent a major opportunity for improving national building energy efficiency. The challenges of rural China are also greater than those of urban areas in many ways because of the limited local capacity and low income levels. The Chinese government wants to expand on new programs to subsidize energy efficiency improvements in rural homes to build capacity for larger-scale improvement. This article summarizes the trends and status of rural building energy use in China. It then provides an overview of the new rural building design standard, and describes options and issues to move forward with implementation.« less

  2. Final Technical Report for GO17004 Regulatory Logic: Codes and Standards for the Hydrogen Economy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakarado, Gary L.

    The objectives of this project are to: develop a robust supporting research and development program to provide critical hydrogen behavior data and a detailed understanding of hydrogen combustion and safety across a range of scenarios, needed to establish setback distances in building codes and minimize the overall data gaps in code development; support and facilitate the completion of technical specifications by the International Organization for Standardization (ISO) for gaseous hydrogen refueling (TS 20012) and standards for on-board liquid (ISO 13985) and gaseous or gaseous blend (ISO 15869) hydrogen storage by 2007; support and facilitate the effort, led by the NFPA,more » to complete the draft Hydrogen Technologies Code (NFPA 2) by 2008; with experimental data and input from Technology Validation Program element activities, support and facilitate the completion of standards for bulk hydrogen storage (e.g., NFPA 55) by 2008; facilitate the adoption of the most recently available model codes (e.g., from the International Code Council [ICC]) in key regions; complete preliminary research and development on hydrogen release scenarios to support the establishment of setback distances in building codes and provide a sound basis for model code development and adoption; support and facilitate the development of Global Technical Regulations (GTRs) by 2010 for hydrogen vehicle systems under the United Nations Economic Commission for Europe, World Forum for Harmonization of Vehicle Regulations and Working Party on Pollution and Energy Program (ECE-WP29/GRPE); and to Support and facilitate the completion by 2012 of necessary codes and standards needed for the early commercialization and market entry of hydrogen energy technologies.« less

  3. Survey of existing performance requirements in codes and standards for light-frame construction

    Treesearch

    G. E. Sherwood

    1980-01-01

    Present building codes and standards are a combination of specifications and performance criteria. Where specifications prevail, the introduction f new materials or methods can be a long, cumbersome process. To facilitate the introduction of new technology, performance requirements are becoming more prevalent. In some areas, there is a lack of information on which to...

  4. Revision of seismic design codes corresponding to building damages in the ``5.12'' Wenchuan earthquake

    NASA Astrophysics Data System (ADS)

    Wang, Yayong

    2010-06-01

    A large number of buildings were seriously damaged or collapsed in the “5.12” Wenchuan earthquake. Based on field surveys and studies of damage to different types of buildings, seismic design codes have been updated. This paper briefly summarizes some of the major revisions that have been incorporated into the “Standard for classification of seismic protection of building constructions GB50223-2008” and “Code for Seismic Design of Buildings GB50011-2001.” The definition of seismic fortification class for buildings has been revisited, and as a result, the seismic classifications for schools, hospitals and other buildings that hold large populations such as evacuation shelters and information centers have been upgraded in the GB50223-2008 Code. The main aspects of the revised GB50011-2001 code include: (a) modification of the seismic intensity specified for the Provinces of Sichuan, Shanxi and Gansu; (b) basic conceptual design for retaining walls and building foundations in mountainous areas; (c) regularity of building configuration; (d) integration of masonry structures and pre-cast RC floors; (e) requirements for calculating and detailing stair shafts; and (f) limiting the use of single-bay RC frame structures. Some significant examples of damage in the epicenter areas are provided as a reference in the discussion on the consequences of collapse, the importance of duplicate structural systems, and the integration of RC and masonry structures.

  5. 49 CFR 41.115 - New buildings to be leased for DOT occupancy.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... compliance may include the engineer's and architect's authenticated verifications of seismic design codes... design and construction of new buildings to be leased for DOT occupancy or use will ensure that each building is designed and constructed in accord with the seismic design and construction standards set out...

  6. 49 CFR 41.115 - New buildings to be leased for DOT occupancy.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... compliance may include the engineer's and architect's authenticated verifications of seismic design codes... design and construction of new buildings to be leased for DOT occupancy or use will ensure that each building is designed and constructed in accord with the seismic design and construction standards set out...

  7. Energy Efficiency Building Code for Commercial Buildings in Sri Lanka

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Busch, John; Greenberg, Steve; Rubinstein, Francis

    2000-09-30

    1.1.1 To encourage energy efficient design or retrofit of commercial buildings so that they may be constructed, operated, and maintained in a manner that reduces the use of energy without constraining the building function, the comfort, health, or the productivity of the occupants and with appropriate regard for economic considerations. 1.1.2 To provide criterion and minimum standards for energy efficiency in the design or retrofit of commercial buildings and provide methods for determining compliance with them. 1.1.3 To encourage energy efficient designs that exceed these criterion and minimum standards.

  8. Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

    DOE PAGES

    Lee, Eleanor; Pang, Xiufeng; McNeil, Andrew; ...

    2015-05-29

    Here, as rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the US model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shadingmore » products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24-66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30-80% reductions in perimeter zone HVAC electricity use in Beijing and 18-38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.« less

  9. Assessment of the Potential to Achieve very Low Energy Use in Public Buildings in China with Advanced Window and Shading Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Eleanor; Pang, Xiufeng; McNeil, Andrew

    Here, as rapid growth in the construction industry continues to occur in China, the increased demand for a higher standard living is driving significant growth in energy use and demand across the country. Building codes and standards have been implemented to head off this trend, tightening prescriptive requirements for fenestration component measures using methods similar to the US model energy code American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 90.1. The objective of this study is to (a) provide an overview of applicable code requirements and current efforts within China to enable characterization and comparison of window and shadingmore » products, and (b) quantify the load reduction and energy savings potential of several key advanced window and shading systems, given the divergent views on how space conditioning requirements will be met in the future. System-level heating and cooling loads and energy use performance were evaluated for a code-compliant large office building using the EnergyPlus building energy simulation program. Commercially-available, highly-insulating, low-emittance windows were found to produce 24-66% lower perimeter zone HVAC electricity use compared to the mandated energy-efficiency standard in force (GB 50189-2005) in cold climates like Beijing. Low-e windows with operable exterior shading produced up to 30-80% reductions in perimeter zone HVAC electricity use in Beijing and 18-38% reductions in Shanghai compared to the standard. The economic context of China is unique since the cost of labor and materials for the building industry is so low. Broad deployment of these commercially available technologies with the proper supporting infrastructure for design, specification, and verification in the field would enable significant reductions in energy use and greenhouse gas emissions in the near term.« less

  10. ARES (Automated Residential Energy Standard) 1.2: User`s guide, in support of proposed interim energy conservation voluntary performance standards for new non-federal residential buildings: Volume 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    The ARES (Automated Residential Energy Standard) User`s Guide is designed to the user successfully operate the ARES computer program. This guide assumes that the user is familiar with basic PC skills such as using a keyboard and loading a disk drive. The ARES computer program was designed to assist building code officials in creating a residential energy standard based on local climate and costs.

  11. Development of Automated Procedures to Generate Reference Building Models for ASHRAE Standard 90.1 and India’s Building Energy Code and Implementation in OpenStudio

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Andrew; Haves, Philip; Jegi, Subhash

    This paper describes a software system for automatically generating a reference (baseline) building energy model from the proposed (as-designed) building energy model. This system is built using the OpenStudio Software Development Kit (SDK) and is designed to operate on building energy models in the OpenStudio file format.

  12. 24 CFR 905.312 - Design and construction.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... constructed in compliance with: (1) A national building code, such as those developed by the International Code Council or the National Fire Protection Association; and the IECC or ASHRAE 90.1-2010 (both... a successor energy code or standard that has been adopted by HUD pursuant to 42 U.S.C. 12709 or...

  13. Codes and standards for structural wood products and their use in the United States

    Treesearch

    David W. Green; Roland Hernandez

    1998-01-01

    The system of model building codes and voluntary product standards used in the United States for structural lumber and engineered wood products can appear complicated and confusing to those introduced to it for the first time. This paper is a discussion of the various types of structural wood products commonly used in U.S. residential and commercial construction and...

  14. 7 CFR 1924.4 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ...) Contractor. The individual or organization with whom the borrower enters into a contract for construction or...)(i)(E) of this subpart. (2) Voluntary national model building codes (model codes). Comprehensive... Department of Housing and Urban Development (HUD) Minimum Property Standards for Housing, Handbook 4910.1...

  15. Final Report. An Integrated Partnership to Create and Lead the Solar Codes and Standards Working Group

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthal, Andrew

    The DOE grant, “An Integrated Partnership to Create and Lead the Solar Codes and Standards Working Group,” to New Mexico State University created the Solar America Board for Codes and Standards (Solar ABCs). From 2007 – 2013 with funding from this grant, Solar ABCs identified current issues, established a dialogue among key stakeholders, and catalyzed appropriate activities to support the development of codes and standards that facilitated the installation of high quality, safe photovoltaic systems. Solar ABCs brought the following resources to the PV stakeholder community; Formal coordination in the planning or revision of interrelated codes and standards removing “stovemore » pipes” that have only roofing experts working on roofing codes, PV experts on PV codes, fire enforcement experts working on fire codes, etc.; A conduit through which all interested stakeholders were able to see the steps being taken in the development or modification of codes and standards and participate directly in the processes; A central clearing house for new documents, standards, proposed standards, analytical studies, and recommendations of best practices available to the PV community; A forum of experts that invites and welcomes all interested parties into the process of performing studies, evaluating results, and building consensus on standards and code-related topics that affect all aspects of the market; and A biennial gap analysis to formally survey the PV community to identify needs that are unmet and inhibiting the market and necessary technical developments.« less

  16. 25 CFR 256.22 - How can I be sure that the work that is being done on my dwelling meets minimum construction...

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... construction, a trained and qualified servicing housing office representative or building inspector will review the construction to ensure that it meets applicable minimum construction standards and building codes...

  17. 25 CFR 256.22 - How can I be sure that the work that is being done on my dwelling meets minimum construction...

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... construction, a trained and qualified servicing housing office representative or building inspector will review the construction to ensure that it meets applicable minimum construction standards and building codes...

  18. 25 CFR 256.22 - How can I be sure that the work that is being done on my dwelling meets minimum construction...

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... construction, a trained and qualified servicing housing office representative or building inspector will review the construction to ensure that it meets applicable minimum construction standards and building codes...

  19. 25 CFR 256.22 - How can I be sure that the work that is being done on my dwelling meets minimum construction...

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... construction, a trained and qualified servicing housing office representative or building inspector will review the construction to ensure that it meets applicable minimum construction standards and building codes...

  20. 25 CFR 256.22 - How can I be sure that the work that is being done on my dwelling meets minimum construction...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... construction, a trained and qualified servicing housing office representative or building inspector will review the construction to ensure that it meets applicable minimum construction standards and building codes...

  1. Energy Codes at a Glance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cole, Pamala C.; Richman, Eric E.

    2008-09-01

    Feeling dim from energy code confusion? Read on to give your inspections a charge. The U.S. Department of Energy’s Building Energy Codes Program addresses hundreds of inquiries from the energy codes community every year. This article offers clarification for topics of confusion submitted to BECP Technical Support of interest to electrical inspectors, focusing on the residential and commercial energy code requirements based on the most recently published 2006 International Energy Conservation Code® and ANSI/ASHRAE/IESNA1 Standard 90.1-2004.

  2. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  3. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  4. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  5. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  6. 24 CFR 983.155 - Completion of housing.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... with local requirements (such as code and zoning requirements); and (ii) An architect's certification that the housing complies with: (A) HUD housing quality standards; (B) State, local, or other building codes; (C) Zoning; (D) The rehabilitation work write-up (for rehabilitated housing) or the work...

  7. Program for developing and implementing a new approach to designing for fire safety in buildings

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The traditional method of providing for fire safety in buildings through reliance on codes and standards that prescribe specific measures to be taken in the design and construction of buildings to minimize the potential for a fire occurring and to protect property and life should a fire occur was evaluated. A new approach to designing for fire safety in buildings is outlined.

  8. 10 CFR 434.103 - Referenced standards (RS).

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Referenced standards (RS). 434.103 Section 434.103 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.103 Referenced standards (RS). 103.1The...

  9. 10 CFR 434.103 - Referenced standards (RS).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Referenced standards (RS). 434.103 Section 434.103 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Administration and Enforcement-General § 434.103 Referenced standards (RS). 103.1The...

  10. Effect of URM infills on seismic vulnerability of Indian code designed RC frame buildings

    NASA Astrophysics Data System (ADS)

    Haldar, Putul; Singh, Yogendra; Paul, D. K.

    2012-03-01

    Unreinforced Masonry (URM) is the most common partitioning material in framed buildings in India and many other countries. Although it is well-known that under lateral loading the behavior and modes of failure of the frame buildings change significantly due to infill-frame interaction, the general design practice is to treat infills as nonstructural elements and their stiffness, strength and interaction with the frame is often ignored, primarily because of difficulties in simulation and lack of modeling guidelines in design codes. The Indian Standard, like many other national codes, does not provide explicit insight into the anticipated performance and associated vulnerability of infilled frames. This paper presents an analytical study on the seismic performance and fragility analysis of Indian code-designed RC frame buildings with and without URM infills. Infills are modeled as diagonal struts as per ASCE 41 guidelines and various modes of failure are considered. HAZUS methodology along with nonlinear static analysis is used to compare the seismic vulnerability of bare and infilled frames. The comparative study suggests that URM infills result in a significant increase in the seismic vulnerability of RC frames and their effect needs to be properly incorporated in design codes.

  11. Probabilistic seismic hazard zonation for the Cuban building code update

    NASA Astrophysics Data System (ADS)

    Garcia, J.; Llanes-Buron, C.

    2013-05-01

    A probabilistic seismic hazard assessment has been performed in response to a revision and update of the Cuban building code (NC-46-99) for earthquake-resistant building construction. The hazard assessment have been done according to the standard probabilistic approach (Cornell, 1968) and importing the procedures adopted by other nations dealing with the problem of revising and updating theirs national building codes. Problems of earthquake catalogue treatment, attenuation of peak and spectral ground acceleration, as well as seismic source definition have been rigorously analyzed and a logic-tree approach was used to represent the inevitable uncertainties encountered through the whole seismic hazard estimation process. The seismic zonation proposed here, is formed by a map where it is reflected the behaviour of the spectral acceleration values for short (0.2 seconds) and large (1.0 seconds) periods on rock conditions with a 1642 -year return period, which being considered as maximum credible earthquake (ASCE 07-05). In addition, other three design levels are proposed (severe earthquake: with a 808 -year return period, ordinary earthquake: with a 475 -year return period and minimum earthquake: with a 225 -year return period). The seismic zonation proposed here fulfils the international standards (IBC-ICC) as well as the world tendencies in this thematic.

  12. Fire related hazards of cables: The Canadian position development of fire resistant inside wiring cable

    NASA Astrophysics Data System (ADS)

    Hartley, M. D.; Jaques, R. E.

    1986-11-01

    The Canadian Electrical Code and the National Building Code in Canada recognize only two designations in regards to fire resistance of cables; cables for use in combustible (residential) buildings and cables for use in non-combustible buildings. The Test standard for cables for non-combustible buildings resembles IEEE-383. However, it is more severe; particularly for small nonarmoured cables such as Inside Wiring Cable. This forthcoming requirement has necessitated material and product development. Although an Inside Wiring cable modification of both insulation and jacket was undertaken, the large volume fraction of combustible material in the jacket vis a vis the insulation made it the area of greatest impact. The paper outlines the development and its effect on cable performance.

  13. Compliance Verification Paths for Residential and Commercial Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Conover, David R.; Makela, Eric J.; Fannin, Jerica D.

    2011-10-10

    This report looks at different ways to verify energy code compliance and to ensure that the energy efficiency goals of an adopted document are achieved. Conformity assessment is the body of work that ensures compliance, including activities that can ensure residential and commercial buildings satisfy energy codes and standards. This report identifies and discusses conformity-assessment activities and provides guidance for conducting assessments.

  14. 3 CFR 8672 - Proclamation 8672 of May 9, 2011. National Building Safety Month, 2011

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... public and private sectors—to implement effective standards and codes that sustain safe and resilient structures. We need innovation and partnerships at all levels of society to develop transformative... Proclamation Building safety is a critical component of our homeland security, our personal and public safety...

  15. Windows: Life after Wire.

    ERIC Educational Resources Information Center

    Razwick, Jerry

    2003-01-01

    Although wired glass is extremely common in school buildings, the International Building Code adopted new standards that eliminate the use of traditional wired glass in K-12 schools, daycare centers, and athletic facilities. Wired glass breaks easily, and the wires can cause significant injuries by forming dangerous snags when the glass breaks.…

  16. Building America Top Innovations 2012: Affordable High Performance in Production Homes: Artistic Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    none,

    2013-01-01

    This Building America Top Innovations profile describes Artistic Homes, a successful New Mexico production builder, who went from code-minimum to under HERS 50 standard on every home, with optional PV upgrades to HERS 35 or true net zero on every home plan offered.

  17. Analysis of IECC (2003, 2006, 2009) and ASHRAE 90.1-2007 Commercial Energy Code Requirements for Mesa, AZ.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, Yunzhi; Gowri, Krishnan

    2011-02-28

    This report summarizes code requirements and energy savings of commercial buildings in Climate Zone 2B built to the 2009 IECC and ASHRAE Standard 90.1-2007 when compared to the 2003 IECC and the 2006 IECC. In general, the 2009 IECC and ASHRAE Standard 90.1-2007 have higher insulation requirements for exterior walls, roof, and windows and have higher efficiency requirements for HVAC equipment. HVAC equipment efficiency requirements are governed by National Appliance Conversion Act of 1987 (NAECA), and are applicable irrespective of the IECC version adopted. The energy analysis results show that commercial buildings meeting the 2009 IECC requirements save 4.4% tomore » 9.5% site energy and 4.1% to 9.9% energy cost when compared to the 2006 IECC; and save 10.6% to 29.4% site energy and 10.3% to 29.3% energy cost when compared to the 2003 IECC. Similar analysis comparing ASHRAE Standard 90.1-2007 requirements to the 2006 IECC shows that the energy savings are in the 4.0% to 10.7% for multi-family and retail buildings, but less than 2% for office buildings. Further comparison of ASHRAE Standard 90.1-2007 requirements to the 2003 IECC show site energy savings in the range of 7.7% to 30.6% and energy cost savings range from 7.9% to 30.3%. Both the 2009 IECC and ASHRAE Standard 90.1-2007 have the potential to save energy by comparable levels for most building types.« less

  18. A High-Granularity Approach to Modeling Energy Consumption and Savings Potential in the U.S. Residential Building Stock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Building simulations are increasingly used in various applications related to energy efficient buildings. For individual buildings, applications include: design of new buildings, prediction of retrofit savings, ratings, performance path code compliance and qualification for incentives. Beyond individual building applications, larger scale applications (across the stock of buildings at various scales: national, regional and state) include: codes and standards development, utility program design, regional/state planning, and technology assessments. For these sorts of applications, a set of representative buildings are typically simulated to predict performance of the entire population of buildings. Focusing on the U.S. single-family residential building stock, this paper willmore » describe how multiple data sources for building characteristics are combined into a highly-granular database that preserves the important interdependencies of the characteristics. We will present the sampling technique used to generate a representative set of thousands (up to hundreds of thousands) of building models. We will also present results of detailed calibrations against building stock consumption data.« less

  19. Impacts: NIST Building and Fire Research Laboratory (technical and societal)

    NASA Astrophysics Data System (ADS)

    Raufaste, N. J.

    1993-08-01

    The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.

  20. OpenEIS. Users Guide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Woohyun; Lutes, Robert G.; Katipamula, Srinivas

    This document is a users guide for OpenEIS, a software code designed to provide standard methods for authoring, sharing, testing, using and improving algorithms for operational building energy efficiency.

  1. Chargemaster maintenance: think 'spring cleaning' all year round.

    PubMed

    Barton, Shawn; Lancaster, Dani; Bieker, Mike

    2008-11-01

    Steps toward maintaining a standardized chargemaster include: Building a corporate chargemaster maintenance team. Developing a core research function. Designating hospital liaisons. Publishing timely reports on facility compliance. Using system codes to identify charges. Selecting chargemaster maintenance software. Developing a standard chargemaster data repository. Educating staff.

  2. 3 CFR 8967 - Proclamation 8967 of April 30, 2013. National Building Safety Month, 2013

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... States of America A Proclamation When natural disasters and other hazards put American lives at risk... redevelopment. To get involved, visit www.Ready.gov. Time and again, devastating natural disasters have tested... stakeholders across our country to adopt disaster-resistant building codes and standards. We are collaborating...

  3. Evaluation of Passive Vents in New Construction Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sean Maxwell; Berger, David; Zuluaga, Marc

    Exhaust ventilation and corresponding outdoor air strategies are being implemented in high performance, new construction, multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards.

  4. 49 CFR 41.117 - Buildings built with Federal assistance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... architect's authenticated verifications of seismic design codes, standards, and practices used in the design... financial assistance, after July 14, 1993 must be designed and constructed in accord with seismic standards... of compliance with the seismic design and construction requirements of this part is required prior to...

  5. Safety and health in the construction of fixed offshore installations in the petroleum industry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1981-01-01

    A meeting convened by the ILO (International Labor Office) on safety problems in the offshore petroleum industry recommended the preparation of a code of practice setting out standards for safety and health during the construction of fixed offshore installations. Such a code, to be prepared by the ILO in co-operation with other bodies, including the Inter-Governmental Maritime Consultative Organisation (IMCO), was to take into consideration existing standards applicable to offshore construction activities and to supplement the ILO codes of practice on safety and health in building and civil engineering work, shipbuilding and ship repairing. (Copyright (c) International Labour Organisation 1981.)

  6. Energy Savings Analysis of the Proposed Revision of the Washington D.C. Non-Residential Energy Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Athalye, Rahul A.; Hart, Philip R.

    This report presents the results of an assessment of savings for the proposed Washington D.C. energy code relative to ASHRAE Standard 90.1-2010. It includes annual and life cycle savings for site energy, source energy, energy cost, and carbon dioxide emissions that would result from adoption and enforcement of the proposed code for newly constructed buildings in Washington D.C. over a five year period.

  7. Building America FY 2016 Annual Report: Building America Is Driving Real Solutions in the Race to Zero Energy Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrar, Sara; Rothgeb, Stacey; Polly, Ben

    The U.S. Department of Energy (DOE) Building America Program enables the transformation of the U.S. housing industry to achieve energy savings through energy-efficient, high-performance homes with improved durability, comfort, and health for occupants. Building America bridges the gap between the development of emerging technologies and the adoption of codes and standards by engaging industry partners in applied research, development, and demonstration of high-performance solutions.

  8. ASME Code Efforts Supporting HTGRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.K. Morton

    2010-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This reportmore » discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.« less

  9. ASME Code Efforts Supporting HTGRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.K. Morton

    2011-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This reportmore » discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.« less

  10. ASME Code Efforts Supporting HTGRs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D.K. Morton

    2012-09-01

    In 1999, an international collaborative initiative for the development of advanced (Generation IV) reactors was started. The idea behind this effort was to bring nuclear energy closer to the needs of sustainability, to increase proliferation resistance, and to support concepts able to produce energy (both electricity and process heat) at competitive costs. The U.S. Department of Energy has supported this effort by pursuing the development of the Next Generation Nuclear Plant, a high temperature gas-cooled reactor. This support has included research and development of pertinent data, initial regulatory discussions, and engineering support of various codes and standards development. This reportmore » discusses the various applicable American Society of Mechanical Engineers (ASME) codes and standards that are being developed to support these high temperature gascooled reactors during construction and operation. ASME is aggressively pursuing these codes and standards to support an international effort to build the next generation of advanced reactors so that all can benefit.« less

  11. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...., materials, allowable stresses, design; (6) Excavation; (e) Materials standards. (f) Construction components...) Plumbing fixtures; (7) Water supply and distribution; (8) Storm drain systems. (j) Electrical. (1) Wiring...

  12. 24 CFR 200.925b - Residential and institutional building code comparison items.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...., materials, allowable stresses, design; (6) Excavation; (e) Materials standards. (f) Construction components...) Plumbing fixtures; (7) Water supply and distribution; (8) Storm drain systems. (j) Electrical. (1) Wiring...

  13. Residential photovoltaic module and array requirements study

    NASA Technical Reports Server (NTRS)

    Nearhoof, S. L.; Oster, J. R.

    1979-01-01

    Design requirements for photovoltaic modules and arrays used in residential applications were identified. Building codes and referenced standards were reviewed for their applicability to residential photovoltaic array installations. Four installation types were identified - integral (replaces roofing), direct (mounted on top of roofing), stand-off (mounted away from roofing), and rack (for flat or low slope roofs, or ground mounted). Installation costs were developed for these mounting types as a function of panel/module size. Studies were performed to identify optimum module shapes and sizes and operating voltage cost drivers. It is concluded that there are no perceived major obstacles to the use of photovoltaic modules in residential arrays. However, there is no applicable building code category for residential photovoltaic modules and arrays and additional work with standards writing organizations is needed to develop residential module and array requirements.

  14. Airside HVAC BESTEST: HVAC Air-Distribution System Model Test Cases for ASHRAE Standard 140

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Judkoff, Ronald; Neymark, Joel; Kennedy, Mike D.

    This paper summarizes recent work to develop new airside HVAC equipment model analytical verification test cases for ANSI/ASHRAE Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. The analytical verification test method allows comparison of simulation results from a wide variety of building energy simulation programs with quasi-analytical solutions, further described below. Standard 140 is widely cited for evaluating software for use with performance-path energy efficiency analysis, in conjunction with well-known energy-efficiency standards including ASHRAE Standard 90.1, the International Energy Conservation Code, and other international standards. Airside HVAC Equipment is a common area ofmore » modelling not previously explicitly tested by Standard 140. Integration of the completed test suite into Standard 140 is in progress.« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Farrar, Sara; Rothgeb, Stacey; Polly, Ben

    The U.S. Department of Energy (DOE) Building America Program enables the transformation of the U.S. housing industry to achieve energy savings through energy-efficient, high-performance homes with improved durability, comfort, and health for occupants. Building America bridges the gap between the development of emerging technologies and the adoption of codes and standards by engaging industry partners in applied research, development, and demonstration of high-performance solutions.

  16. 48 CFR 1552.211-80 - Data standards for the transmission of laboratory measurement results.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... this contract. Copies of the Order may be obtained by written request to: Office of Information Resources Management, Information Management and Systems Division, Mail Code (3404), Ariel Rios Building...

  17. 48 CFR 1552.211-80 - Data standards for the transmission of laboratory measurement results.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... this contract. Copies of the Order may be obtained by written request to: Office of Information Resources Management, Information Management and Systems Division, Mail Code (3404), Ariel Rios Building...

  18. 48 CFR 1552.211-80 - Data standards for the transmission of laboratory measurement results.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... this contract. Copies of the Order may be obtained by written request to: Office of Information Resources Management, Information Management and Systems Division, Mail Code (3404), Ariel Rios Building...

  19. An international survey of building energy codes and their implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Roshchanka, Volha; Graham, Peter

    Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy demand from buildings. Access to benefits of building energy codes depends on comprehensive coverage of buildings by type, age, size, andmore » geographic location; an implementation framework that involves a certified agency to inspect construction at critical stages; and independently tested, rated, and labeled building energy materials. Training and supporting tools are another element of successful code implementation, and their role is growing in importance, given the increasing flexibility and complexity of building energy codes. Some countries have also introduced compliance evaluation and compliance checking protocols to improve implementation. This article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less

  20. High-Penetration Photovoltaics Standards and Codes Workshop, Denver, Colorado, May 20, 2010: Workshop Proceedings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coddington, M.; Kroposki, B.; Basso, T.

    Effectively interconnecting high-level penetration of photovoltaic (PV) systems requires careful technical attention to ensuring compatibility with electric power systems. Standards, codes, and implementation have been cited as major impediments to widespread use of PV within electric power systems. On May 20, 2010, in Denver, Colorado, the National Renewable Energy Laboratory, in conjunction with the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), held a workshop to examine the key technical issues and barriers associated with high PV penetration levels with an emphasis on codes and standards. This workshop included building upon results of the Highmore » Penetration of Photovoltaic (PV) Systems into the Distribution Grid workshop held in Ontario California on February 24-25, 2009, and upon the stimulating presentations of the diverse stakeholder presentations.« less

  1. Taking the stairs instead: The impact of workplace design standards on health promotion strategies.

    PubMed

    McGann, Sarah; Jancey, Jonine; Tye, Marian

    2013-01-01

    Comprehensive health promotion in Western Australia has been conducted from the point of views of policy development, promotion, education and service delivery. Much of this recent work has been focused on supporting workplaces - but there has yet to be any real focus on the design of the actual physical workplace environment from a health promotion perspective. This paper is aimed at highlighting the gap in health promotion knowledge by addressing how the disciplines of architecture and health promotion can work together to challenge the regulations that dictate design practice and ultimately bridge that gap for long-term change. The overarching aim is to undertake further evidenced-based research that will inform best practice in the planning and design of workplaces to reduce sedentary behaviour and increase opportunities for physical activity. Within this wide objective this paper focuses in particular on the idea of stairs-versus-lift movement strategies within office buildings. By examining building design guidelines from a health promotion perspective we expose a central dichotomy, where health promotion posters say "Take the stairs instead" whereas the language of building design suggests that the lift is best. From a design point of view, the National Codes of Construction (NCC), formally known as the Building Codes of Australia (BCA), the essential technical regulation for all building design and construction, primarily addresses the concepts of 'egress' and 'travel distance' for escape in the event of fire, and building access in terms of universal access. Additionally, The Property Council of Australia's Guide to Office Building Quality prioritises lift performance criteria along with the quality and experience of lift use as a major grading factor. There is no provision in either set of standards for staircase quality and experience. The stairs, despite being promoted as better life choice for better health, is not promoted through these building codes nor, consequently, through the building design in actuality. It is proposed that health promotion strategies could be coupled with design-led movement strategies in workplace design so that the promotional language, such as "take the stairs instead", is balanced by the design language of the building.

  2. ANSI/ASHRAE/IES Standard 90.1-2013 Preliminary Determination: Qualitative Analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Halverson, Mark A.; Hart, Reid; Athalye, Rahul A.

    2014-03-01

    Section 304(b) of the Energy Conservation and Production Act (ECPA), as amended, requires the Secretary of Energy to make a determination each time a revised version of ASHRAE Standard 90.1 is published with respect to whether the revised standard would improve energy efficiency in commercial buildings. When the U.S. Department of Energy (DOE) issues an affirmative determination on Standard 90.1, states are statutorily required to certify within two years that they have reviewed and updated the commercial provisions of their building energy code, with respect to energy efficiency, to meet or exceed the revised standard. This report provides a preliminarymore » qualitative analysis of all addenda to ANSI/ASHRAE/IES Standard 90.1-2010 (referred to as Standard 90.1-2010 or 2010 edition) that were included in ANSI/ASHRAE/IES Standard 90.1-2013 (referred to as Standard 90.1-2013 or 2013 edition).« less

  3. Country Report on Building Energy Codes in Australia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shui, Bin; Evans, Meredydd; Somasundaram, Sriram

    2009-04-02

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America (U.S.). This reports gives an overview of the development of building energy codes in Australia, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, and lighting) for commercial and residential buildings in Australia.

  4. The human dimensions of energy use in buildings: A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    D'Oca, Simona; Hong, Tianzhen; Langevin, Jared

    The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.« less

  5. The human dimensions of energy use in buildings: A review

    DOE PAGES

    D'Oca, Simona; Hong, Tianzhen; Langevin, Jared

    2017-08-19

    The “human dimensions” of energy use in buildings refer to the energy-related behaviors of key stakeholders that affect energy use over the building life cycle. Stakeholders include building designers, operators, managers, engineers, occupants, industry, vendors, and policymakers, who directly or indirectly influence the acts of designing, constructing, living, operating, managing, and regulating the built environments, from individual building up to the urban scale. Among factors driving high-performance buildings, human dimensions play a role that is as significant as that of technological advances. However, this factor is not well understood, and, as a result, human dimensions are often ignored or simplifiedmore » by stakeholders. This work presents a review of the literature on human dimensions of building energy use to assess the state-of-the-art in this topic area. The paper highlights research needs for fully integrating human dimensions into the building design and operation processes with the goal of reducing energy use in buildings while enhancing occupant comfort and productivity. This research focuses on identifying key needs for each stakeholder involved in a building's life cycle and takes an interdisciplinary focus that spans the fields of architecture and engineering design, sociology, data science, energy policy, codes, and standards to provide targeted insights. Greater understanding of the human dimensions of energy use has several potential benefits including reductions in operating cost for building owners; enhanced comfort conditions and productivity for building occupants; more effective building energy management and automation systems for building operators and energy managers; and the integration of more accurate control logic into the next generation of human-in-the-loop technologies. The review concludes by summarizing recommendations for policy makers and industry stakeholders for developing codes, standards, and technologies that can leverage the human dimensions of energy use to reliably predict and achieve energy use reductions in the residential and commercial buildings sectors.« less

  6. Building energy simulation in real time through an open standard interface

    DOE PAGES

    Pang, Xiufeng; Nouidui, Thierry S.; Wetter, Michael; ...

    2015-10-20

    Building energy models (BEMs) are typically used for design and code compliance for new buildings and in the renovation of existing buildings to predict energy use. We present the increasing adoption of BEM as standard practice in the building industry presents an opportunity to extend the use of BEMs into construction, commissioning and operation. In 2009, the authors developed a real-time simulation framework to execute an EnergyPlus model in real time to improve building operation. This paper reports an enhancement of that real-time energy simulation framework. The previous version only works with software tools that implement the custom co-simulation interfacemore » of the Building Controls Virtual Test Bed (BCVTB), such as EnergyPlus, Dymola and TRNSYS. The new version uses an open standard interface, the Functional Mockup Interface (FMI), to provide a generic interface to any application that supports the FMI protocol. In addition, the new version utilizes the Simple Measurement and Actuation Profile (sMAP) tool as the data acquisition system to acquire, store and present data. Lastly, this paper introduces the updated architecture of the real-time simulation framework using FMI and presents proof-of-concept demonstration results which validate the new framework.« less

  7. Field Testing of Compartmentalization Methods for Multifamily Construction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ueno, K.; Lstiburek, J. W.

    2015-03-01

    The 2012 International Energy Conservation Code (IECC) has an airtightness requirement of 3 air changes per hour at 50 Pascals test pressure (3 ACH50) for single-family and multifamily construction (in climate zones 3–8). The Leadership in Energy & Environmental Design certification program and ASHRAE Standard 189 have comparable compartmentalization requirements. ASHRAE Standard 62.2 will soon be responsible for all multifamily ventilation requirements (low rise and high rise); it has an exceptionally stringent compartmentalization requirement. These code and program requirements are driving the need for easier and more effective methods of compartmentalization in multifamily buildings.

  8. 25 CFR 1000.243 - What special provisions must be included in an AFA that contains a construction program?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AMENDMENTS TO THE INDIAN SELF-DETERMINATION AND EDUCATION ACT Construction § 1000.243 What special provisions... building codes and applicable engineering standards, appropriate for the particular project; and (3...

  9. Experimental study on lateral strength of wall-slab joint subjected to lateral cyclic load

    NASA Astrophysics Data System (ADS)

    Masrom, Mohd Asha'ari; Mohamad, Mohd Elfie; Hamid, Nor Hayati Abdul; Yusuff, Amer

    2017-10-01

    Tunnel form building has been utilised in building construction since 1960 in Malaysia. This method of construction has been applied extensively in the construction of high rise residential house (multistory building) such as condominium and apartment. Most of the tunnel form buildings have been designed according to British standard (BS) whereby there is no provision for seismic loading. The high-rise tunnel form buildings are vulnerable to seismic loading. The connections between slab and shear walls in the tunnel-form building constitute an essential link in the lateral load resisting mechanism. Malaysia is undergoing a shifting process from BS code to Eurocode (EC) for building construction since the country has realised the safety threats of earthquake. Hence, this study is intended to compare the performance of the interior wall slab joint for a tunnel form structure designed based on Euro and British codes. The experiment included a full scale test of the wall slab joint sub-assemblages under reversible lateral cyclic loading. Two sub-assemblage specimens of the wall slab joint were designed and constructed based on both codes. Each specimen was tested using lateral displacement control (drift control). The specimen designed by using Eurocode was found could survive up to 3.0% drift while BS specimen could last to 1.5% drift. The analysis results indicated that the BS specimen was governed by brittle failure modes with Ductility Class Low (DCL) while the EC specimen behaved in a ductile manner with Ductility Class Medium (DCM). The low ductility recorded in BS specimen was resulted from insufficient reinforcement provided in the BS code specimen. Consequently, the BS specimen could not absorb energy efficiently (low energy dissipation) and further sustain under inelastic deformation.

  10. 7 CFR 4274.337 - Other regulatory requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...

  11. 7 CFR 4274.337 - Other regulatory requirements.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...

  12. 7 CFR 4274.337 - Other regulatory requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... with the seismic provisions of one of the following model building codes or the latest edition of that...) Uniform Building Code; (ii) 1993 Building Officials and Code Administrators International, Inc. (BOCA) National Building Code; or (iii) 1992 Amendments to the Southern Building Code Congress International...

  13. A proposal for seismic evaluation index of mid-rise existing RC buildings in Afghanistan

    NASA Astrophysics Data System (ADS)

    Naqi, Ahmad; Saito, Taiki

    2017-10-01

    Mid-rise RC buildings gradually rise in Kabul and entire Afghanistan since 2001 due to rapid increase of population. To protect the safety of resident, Afghan Structure Code was issued in 2012. But the building constructed before 2012 failed to conform the code requirements. In Japan, new sets of rules and law for seismic design of buildings had been issued in 1981 and severe earthquake damage was disclosed for the buildings designed before 1981. Hence, the Standard for Seismic Evaluation of RC Building published in 1977 has been widely used in Japan to evaluate the seismic capacity of existing buildings designed before 1981. Currently similar problem existed in Afghanistan, therefore, this research examined the seismic capacity of six RC buildings which were built before 2012 in Kabul by applying the seismic screening procedure presented by Japanese standard. Among three screening procedures with different capability, the less detailed screening procedure, the first level of screening, is applied. The study founds an average seismic index (IS-average=0.21) of target buildings. Then, the results were compared with those of more accurate seismic evaluation procedures of Capacity Spectrum Method (CSM) and Time History Analysis (THA). The results for CSM and THA show poor seismic performance of target buildings not able to satisfy the safety design limit (1/100) of the maximum story drift. The target buildings are then improved by installing RC shear walls. The seismic indices of these retrofitted buildings were recalculated and the maximum story drifts were analyzed by CSM and THA. The seismic indices and CSM and THA results are compared and found that building with seismic index larger than (IS-average =0.4) are able to satisfy the safety design limit. Finally, to screen and minimize the earthquake damage over the existing buildings, the judgement seismic index (IS-Judgment=0.5) for the first level of screening is proposed.

  14. Country Report on Building Energy Codes in Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shui, Bin; Evans, Meredydd

    2009-04-06

    This report is part of a series of reports on building energy efficiency codes in countries associated with the Asian Pacific Partnership (APP) - Australia, South Korea, Japan, China, India, and the United States of America . This reports gives an overview of the development of building energy codes in Canada, including national energy policies related to building energy codes, history of building energy codes, recent national projects and activities to promote building energy codes. The report also provides a review of current building energy codes (such as building envelope, HVAC, lighting, and water heating) for commercial and residential buildingsmore » in Canada.« less

  15. Energy Efficiency in India: Challenges and Initiatives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ajay Mathur

    May 13, 2010 EETD Distinguished Lecture: Ajay Mathur is Director General of the Bureau of Energy Efficiency, and a member of the Prime Minister's Council on Climate Change. As Director General of BEE, Dr. Mathur coordinates the national energy efficiency programme, including the standards and labeling programme for equipment and appliances; the energy conservation building code; the industrial energy efficiency programme, and the DSM programmes in the buildings, lighting, and municipal sectors.

  16. Energy Efficiency in India: Challenges and Initiatives

    ScienceCinema

    Ajay Mathur

    2017-12-09

    May 13, 2010 EETD Distinguished Lecture: Ajay Mathur is Director General of the Bureau of Energy Efficiency, and a member of the Prime Minister's Council on Climate Change. As Director General of BEE, Dr. Mathur coordinates the national energy efficiency programme, including the standards and labeling programme for equipment and appliances; the energy conservation building code; the industrial energy efficiency programme, and the DSM programmes in the buildings, lighting, and municipal sectors.

  17. Implementing Nepal's national building code—A case study in patience and persistence

    USGS Publications Warehouse

    Arendt, Lucy; Hortacsu, Ayse; Jaiswal, Kishor; Bevington, John; Shrestha, Surya; Lanning, Forrest; Mentor-William, Garmalia; Naeem, Ghazala; Thibert, Kate

    2017-01-01

    The April 2015 Gorkha Nepal earthquake revealed the relative effectiveness of the Nepal Standard, or national building code (NBC), and irregular compliance with it in different parts of Nepal. Much of the damage to more than half a million Nepal's residential structures may be attributed to the prevalence of owner-built or owner-supervised construction and the lack of owner and builder responsiveness to seismic risk and training in the appropriate means of complying with the NBC. To explain these circumstances, we review the protracted implementation of the NBC and the role played by one organization, the National Society for Earthquake Technology-Nepal (NSET), in the NBC's implementation. We also share observations on building code compliance made by individuals in Nepal participating in workshops led by the Earthquake Engineering Research Institute's 2014 class of Housner Fellows.

  18. C++ Coding Standards for the AMP Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Thomas M; Clarno, Kevin T

    2009-09-01

    This document provides an initial starting point to define the C++ coding standards used by the AMP nuclear fuel performance integrated code project and a part of AMP's software development process. This document draws from the experiences, and documentation [1], of the developers of the Marmot Project at Los Alamos National Laboratory. Much of the software in AMP will be written in C++. The power of C++ can be abused easily, resulting in code that is difficult to understand and maintain. This document gives the practices that should be followed on the AMP project for all new code that ismore » written. The intent is not to be onerous but to ensure that the code can be readily understood by the entire code team and serve as a basis for collectively defining a set of coding standards for use in future development efforts. At the end of the AMP development in fiscal year (FY) 2010, all developers will have experience with the benefits, restrictions, and limitations of the standards described and will collectively define a set of standards for future software development. External libraries that AMP uses do not have to meet these requirements, although we encourage external developers to follow these practices. For any code of which AMP takes ownership, the project will decide on any changes on a case-by-case basis. The practices that we are using in the AMP project have been in use in the Denovo project [2] for several years. The practices build on those given in References [3-5]; the practices given in these references should also be followed. Some of the practices given in this document can also be found in [6].« less

  19. An international survey of building energy codes and their implementation

    DOE PAGES

    Evans, Meredydd; Roshchanka, Volha; Graham, Peter

    2017-08-01

    Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less

  20. An international survey of building energy codes and their implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Roshchanka, Volha; Graham, Peter

    Buildings are key to low-carbon development everywhere, and many countries have introduced building energy codes to improve energy efficiency in buildings. Yet, building energy codes can only deliver results when the codes are implemented. For this reason, studies of building energy codes need to consider implementation of building energy codes in a consistent and comprehensive way. This research identifies elements and practices in implementing building energy codes, covering codes in 22 countries that account for 70% of global energy use in buildings. These elements and practices include: comprehensive coverage of buildings by type, age, size, and geographic location; an implementationmore » framework that involves a certified agency to inspect construction at critical stages; and building materials that are independently tested, rated, and labeled. Training and supporting tools are another element of successful code implementation. Some countries have also introduced compliance evaluation studies, which suggested that tightening energy requirements would only be meaningful when also addressing gaps in implementation (Pitt&Sherry, 2014; U.S. DOE, 2016b). Here, this article provides examples of practices that countries have adopted to assist with implementation of building energy codes.« less

  1. A Stable Whole Building Performance Method for Standard 90.1-Part II

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Eley, Charles

    2016-06-01

    In May of 2013 we introduced a new approach for compliance with Standard 90.1 that was under development based on the Performance Rating Method of Appendix G to Standard 90.11. Since then, the approach has been finalized through Addendum BM to Standard 90.1-2013 and will be published in the 2016 edition of the Standard. In the meantime, ASHRAE has published an advanced copy of Appendix G including Addendum BM and several other addenda so that software developers and energy program administrators can get a preview of what is coming in the 2016 edition of the Standard2. This article is anmore » update on Addendum BM, summarizes changes made to the original concept as introduced in May of 2013, and provides an approach for developing performance targets for code compliance and beyond code programs.« less

  2. Outdoor Lighting Ordinances

    NASA Astrophysics Data System (ADS)

    Davis, S.

    2004-05-01

    A principal means to prevent poor exterior lighting practices is a lighting control ordinance. It is an enforceable legal restriction on specific lighting practices that are deemed unacceptable by the government body having jurisdiction. Outdoor lighting codes have proven to be effective at reducing polluting and trespassing light. A well written exterior lighting code will permit all forms of necessary illumination at reasonable intensities, but will demand shielding and other measures to prevent trespass and light pollution. A good code will also apply to all forms of outdoor lighting, including streets, highways, and exterior signs, as well as the lighting on dwellings, commercial and industrial buildings and building sites. A good code can make exceptions for special uses, provided it complies with an effective standard. The IDA Model Lighting Ordinance is a response to these requests. It is intended as an aid to communities that are seeking to take control of their outdoor lighting, to "take back the night" that is being lost to careless and excessive use of night lighting.

  3. Tribal Green Building Administrative Code Example

    EPA Pesticide Factsheets

    This Tribal Green Building Administrative Code Example can be used as a template for technical code selection (i.e., building, electrical, plumbing, etc.) to be adopted as a comprehensive building code.

  4. A long-term, integrated impact assessment of alternative building energy code scenarios in China

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Eom, Jiyong; Evans, Meredydd

    2014-04-01

    China is the second largest building energy user in the world, ranking first and third in residential and commercial energy consumption. Beginning in the early 1980s, the Chinese government has developed a variety of building energy codes to improve building energy efficiency and reduce total energy demand. This paper studies the impact of building energy codes on energy use and CO2 emissions by using a detailed building energy model that represents four distinct climate zones each with three building types, nested in a long-term integrated assessment framework GCAM. An advanced building stock module, coupled with the building energy model, ismore » developed to reflect the characteristics of future building stock and its interaction with the development of building energy codes in China. This paper also evaluates the impacts of building codes on building energy demand in the presence of economy-wide carbon policy. We find that building energy codes would reduce Chinese building energy use by 13% - 22% depending on building code scenarios, with a similar effect preserved even under the carbon policy. The impact of building energy codes shows regional and sectoral variation due to regionally differentiated responses of heating and cooling services to shell efficiency improvement.« less

  5. ASTM and ASME-BPE Standards--Complying with the Needs of the Pharmaceutical Industry.

    PubMed

    Huitt, William M

    2011-01-01

    Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and standards and then modifying them in order to meet the more stringent requirements of the Food and Drug Administration (FDA). In 1997 the American Society of Mechanical Engineers (ASME) published the first Bioprocessing Equipment (BPE) Standard. Through harmonization efforts this relatively new standard has brought together, scrutinized, and refined industry accepted methodologies together with FDA compliance requirements, and has established an American National Standard that provides a comprehensive set of standards that are integral to the pharmaceutical industry. This article describes various American National Standards, including those developed and published by the American Society for Testing and Materials (ASTM), and how they apply to the pharmaceutical industry. It goes on to discuss the harmonization effort that takes place between the various standards developers in an attempt to prevent conflicts and omissions between the many standards. Also included are examples of tables and figures taken from the ASME-BPE Standard. These examples provide the reader with insight to the relevant content of the ASME-BPE Standard. Designing and building a pharmaceutical facility requires the owner, engineer of record, and constructor to be knowledgeable with regard to the industry codes and standards that apply to this effort. Up until 1997 there were no industry standards directed at the needs and requirements of the pharmaceutical industry. Prior to that time it was a patchwork effort at resourcing and adopting nonpharmaceutical-related codes and standards and then modifying them in order to meet the more stringent requirements of the Food and Drug Administration (FDA). In 1997 the American Society of Mechanical Engineers (ASME) published the first Bioprocessing Equipment (BPE) Standard. In its initial development and ongoing maintenance it works with other American National Standards developers to harmonize the many standards associated with the design, engineering, and construction of bioprocessing facilities. This harmonization effort has established a comprehensive set of standards for the betterment of the pharmaceutical industry at large. This effort is, and will remain, very important as technology, along with new and improved product and processes, evolve into the future.

  6. 10 CFR 435.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... Loan Mortgage Corporation. ICC means International Code Council. IECC means International Energy...

  7. 10 CFR 435.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... Loan Mortgage Corporation. ICC means International Code Council. IECC means International Energy...

  8. 10 CFR 435.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... Loan Mortgage Corporation. ICC means International Code Council. IECC means International Energy...

  9. Seismic Safety Of Simple Masonry Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guadagnuolo, Mariateresa; Faella, Giuseppe

    2008-07-08

    Several masonry buildings comply with the rules for simple buildings provided by seismic codes. For these buildings explicit safety verifications are not compulsory if specific code rules are fulfilled. In fact it is assumed that their fulfilment ensures a suitable seismic behaviour of buildings and thus adequate safety under earthquakes. Italian and European seismic codes differ in the requirements for simple masonry buildings, mostly concerning the building typology, the building geometry and the acceleration at site. Obviously, a wide percentage of buildings assumed simple by codes should satisfy the numerical safety verification, so that no confusion and uncertainty have tomore » be given rise to designers who must use the codes. This paper aims at evaluating the seismic response of some simple unreinforced masonry buildings that comply with the provisions of the new Italian seismic code. Two-story buildings, having different geometry, are analysed and results from nonlinear static analyses performed by varying the acceleration at site are presented and discussed. Indications on the congruence between code rules and results of numerical analyses performed according to the code itself are supplied and, in this context, the obtained result can provide a contribution for improving the seismic code requirements.« less

  10. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  11. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  12. 24 CFR 200.925c - Model codes.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... below. (1) Model Building Codes—(i) The BOCA National Building Code, 1993 Edition, The BOCA National..., Administration, for the Building, Plumbing and Mechanical Codes and the references to fire retardant treated wood... number 2 (Chapter 7) of the Building Code, but including the Appendices of the Code. Available from...

  13. 42 CFR 52b.12 - What are the minimum requirements of construction and equipment?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-8400). (3) ICBO “Uniform Building Code,” Volumes 1-3 (1997). International Conference of Building...-4406). (4) BOCA National Building Code (1996) 1998 Supplement, Building Officials and Code... Southern Building Code Congress (SBCC), 900 Montclair Road, Birmingham, AL 35213-1206 (telephone 205-591...

  14. 42 CFR 52b.12 - What are the minimum requirements of construction and equipment?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...-8400). (3) ICBO “Uniform Building Code,” Volumes 1-3 (1997). International Conference of Building...-4406). (4) BOCA National Building Code (1996) 1998 Supplement, Building Officials and Code... Southern Building Code Congress (SBCC), 900 Montclair Road, Birmingham, AL 35213-1206 (telephone 205-591...

  15. 42 CFR 52b.12 - What are the minimum requirements of construction and equipment?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-8400). (3) ICBO “Uniform Building Code,” Volumes 1-3 (1997). International Conference of Building...-4406). (4) BOCA National Building Code (1996) 1998 Supplement, Building Officials and Code... Southern Building Code Congress (SBCC), 900 Montclair Road, Birmingham, AL 35213-1206 (telephone 205-591...

  16. Assessment of Literature Related to Combustion Appliance Venting Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rapp, V. H.; Less, B. D.; Singer, B. C.

    In many residential building retrofit programs, air tightening to increase energy efficiency is often constrained by safety concerns with naturally vented combustion appliances. Tighter residential buildings more readily depressurize when exhaust equipment is operated, making combustion appliances more prone to backdraft or spill combustion exhaust into the living space. Several measures, such as installation guidelines, vent sizing codes, and combustion safety diagnostics, are in place with the intent to prevent backdrafting and combustion spillage, but the diagnostics conflict and the risk mitigation objective is inconsistent. This literature review summarizes the metrics and diagnostics used to assess combustion safety, documents theirmore » technical basis, and investigates their risk mitigations. It compiles information from the following: codes for combustion appliance venting and installation; standards and guidelines for combustion safety diagnostics; research evaluating combustion safety diagnostics; research investigating wind effects on building depressurization and venting; and software for simulating vent system performance.« less

  17. 10 CFR 435.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Definitions. 435.2 Section 435.2 Energy DEPARTMENT OF... Mandatory Energy Efficiency Standards for Federal Low-Rise Residential Buildings. § 435.2 Definitions. For... International Energy Conservation Code, 2004 Supplement Edition, January 2005 (incorporated by reference, see...

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    The Profile Interface Generator (PIG) is a tool for loosely coupling applications and performance tools. It enables applications to write code that looks like standard C and Fortran functions calls, without requiring that applications link to specific implementations of those function calls. Performance tools can register with PIG in order to listen to only the calls that give information they care about. This interface reduces the build and configuration burden on application developers and allows semantic instrumentation to live in production codes without interfering with production runs.

  19. Building HVAC control knowledge data schema – Towards a unified representation of control system knowledge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Yan; Treado, Stephen J.; Messner, John I.

    Building control systems for Heating, Ventilation, and Air Conditioning (HVAC) play a key role in realizing the functionality and operation of building systems and components. Building Control Knowledge (BCK) is the logic and algorithms embedded throughout building control system. There are different methods to represent the BCK. These methods differ in the selection of BCK representing elements and the format of those elements. There is a lack of standard data schema, for storing, retrieving, and reusing structured BCK. In this study, a modular data schema is created for BCK representation. The data schema contains eleven representing elements, i.e., control modulemore » name, operation mode, system schematic, control flow diagram, data point, alarm, parameter, control sequence, function, and programming code. Each element is defined with specific attributes. This data schema is evaluated through a case study demonstration. The demonstration shows a new way to represent the BCK with standard formats.« less

  20. Kayenta Township Building & Safety Department, Tribal Green Building Code Summit Presentation

    EPA Pesticide Factsheets

    Tribal Green Building Code Summit Presentation by Kayenta Township Building & Safety Department showing how they established the building department, developed a code adoption and enforcement process, and hired staff to carry out the work.

  1. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 12 2013-01-01 2013-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...

  2. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 12 2014-01-01 2013-01-01 true Voluntary National Model Building Codes E Exhibit E to... Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of this...

  3. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 12 2012-01-01 2012-01-01 false Voluntary National Model Building Codes E Exhibit E... National Model Building Codes The following documents address the health and safety aspects of buildings and related structures and are voluntary national model building codes as defined in § 1924.4(h)(2) of...

  4. RECOMMENDED SUB-SLAB DEPRESSURIZATION SYSTEMS DESIGN STANDARD OF THE FLORIDA RADON RESEARCH PROGRAM

    EPA Science Inventory

    The report recommends sub-slab depressurization systems design criteria to the State of Florida's Department of Community Affairs for their building code for radon resistant houses. Numerous details are set forth in the full report. Primary criteria include: (1) the operating soi...

  5. User systems guidelines for software projects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abrahamson, L.

    1986-04-01

    This manual presents guidelines for software standards which were developed so that software project-development teams and management involved in approving the software could have a generalized view of all phases in the software production procedure and the steps involved in completing each phase. Guidelines are presented for six phases of software development: project definition, building a user interface, designing software, writing code, testing code, and preparing software documentation. The discussions for each phase include examples illustrating the recommended guidelines. 45 refs. (DWL)

  6. Hydrogen Infrastructure Testing and Research Facility Video (Text Version)

    Science.gov Websites

    grid integration, continuous code improvement, fuel cell vehicle operation, and renewable hydrogen stations. NRELs research on hydrogen safety provides guidance for safe operation, handling, and use of standards and testing fuel cell and hydrogen components for operation and safety. Building on NRELs Wind-to

  7. 10 CFR 431.323 - Materials incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor... National Standard for electric lamps: Single-Ended Metal Halide Lamps, approved May 5, 2004, IBR approved... (“NFPA 70”), National Electrical Code 2002 Edition, IBR approved for § 431.326; (2) [Reserved] (e) UL...

  8. 10 CFR 431.323 - Materials incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... of Energy, Office of Energy Efficiency and Renewable Energy, Building Technologies Program, 6th Floor... National Standard for electric lamps: Single-Ended Metal Halide Lamps, approved May 5, 2004, IBR approved... (“NFPA 70”), National Electrical Code 2002 Edition, IBR approved for § 431.326; (2) [Reserved] (e) UL...

  9. SNL/CA Facilities Management Design Standards Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rabb, David; Clark, Eva

    2014-12-01

    At Sandia National Laboratories in California (SNL/CA), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/CA applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. The safetymore » and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule.« less

  10. Reuse of textile effluent treatment plant sludge in building materials.

    PubMed

    Balasubramanian, J; Sabumon, P C; Lazar, John U; Ilangovan, R

    2006-01-01

    This study examines the potential reuse of textile effluent treatment plant (ETP) sludge in building materials. The physico-chemical and engineering properties of a composite textile sludge sample from the southern part of India have been studied. The tests were conducted as per Bureau of Indian Standards (BIS) specification codes to evaluate the suitability of the sludge for structural and non-structural application by partial replacement of up to 30% of cement. The cement-sludge samples failed to meet the required strength for structural applications. The strength and other properties met the Bureau of Indian Standards for non-structural materials such as flooring tiles, solid and pavement blocks, and bricks. Results generally meet most ASTM standards for non-structural materials, except that the sludge-amended bricks do not meet the Grade NW brick standard. It is concluded that the substitution of textile ETP sludge for cement, up to a maximum of 30%, may be possible in the manufacturing of non-structural building materials. Detailed leachability and economic feasibility studies need to be carried out as the next step of research.

  11. Impacts of Model Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Athalye, Rahul A.; Sivaraman, Deepak; Elliott, Douglas B.

    The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) periodically evaluates national and state-level impacts associated with energy codes in residential and commercial buildings. Pacific Northwest National Laboratory (PNNL), funded by DOE, conducted an assessment of the prospective impacts of national model building energy codes from 2010 through 2040. A previous PNNL study evaluated the impact of the Building Energy Codes Program; this study looked more broadly at overall code impacts. This report describes the methodology used for the assessment and presents the impacts in terms of energy savings, consumer cost savings, and reduced CO 2 emissions atmore » the state level and at aggregated levels. This analysis does not represent all potential savings from energy codes in the U.S. because it excludes several states which have codes which are fundamentally different from the national model energy codes or which do not have state-wide codes. Energy codes follow a three-phase cycle that starts with the development of a new model code, proceeds with the adoption of the new code by states and local jurisdictions, and finishes when buildings comply with the code. The development of new model code editions creates the potential for increased energy savings. After a new model code is adopted, potential savings are realized in the field when new buildings (or additions and alterations) are constructed to comply with the new code. Delayed adoption of a model code and incomplete compliance with the code’s requirements erode potential savings. The contributions of all three phases are crucial to the overall impact of codes, and are considered in this assessment.« less

  12. 24 CFR 578.75 - General operations.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... assistance under this part must meet State or local building codes, and in the absence of State or local building codes, the International Residential Code or International Building Code (as applicable to the type of structure) of the International Code Council. (2) Services provided with assistance under this...

  13. 24 CFR 578.75 - General operations.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... assistance under this part must meet State or local building codes, and in the absence of State or local building codes, the International Residential Code or International Building Code (as applicable to the type of structure) of the International Code Council. (2) Services provided with assistance under this...

  14. C++ Coding Standards and Style Guide

    NASA Technical Reports Server (NTRS)

    Hughes, Steven; Jun, Linda; Shoan, Wendy

    2005-01-01

    This document is based on the "C Style Guide" (SEL-94-003). It contains recommendations for C++ implementations that build on, or in some cases replace, the style described in the C style guide. Style guidelines on any topics that are not covered in this document can be found in the "C Style Guide." An attempt has been made to indicate when these recommendations are just guidelines or suggestions versus when they are more strongly encouraged. Using coding standards makes code easier to read and maintain. General principles that maximize the readability and maintainability of C++ are: (1) Organize classes using encapsulation and information hiding techniques. (2) Enhance readability through the use of indentation and blank lines. (3) Add comments to header files to help users of classes. (4) Add comments to implementation files to help maintainers of classes. (5) Create names that are meaningful and readable.

  15. The study on dynamic cadastral coding rules based on kinship relationship

    NASA Astrophysics Data System (ADS)

    Xu, Huan; Liu, Nan; Liu, Renyi; Lu, Jingfeng

    2007-06-01

    Cadastral coding rules are an important supplement to the existing national and local standard specifications for building cadastral database. After analyzing the course of cadastral change, especially the parcel change with the method of object-oriented analysis, a set of dynamic cadastral coding rules based on kinship relationship corresponding to the cadastral change is put forward and a coding format composed of street code, block code, father parcel code, child parcel code and grandchild parcel code is worked out within the county administrative area. The coding rule has been applied to the development of an urban cadastral information system called "ReGIS", which is not only able to figure out the cadastral code automatically according to both the type of parcel change and the coding rules, but also capable of checking out whether the code is spatiotemporally unique before the parcel is stored in the database. The system has been used in several cities of Zhejiang Province and got a favorable response. This verifies the feasibility and effectiveness of the coding rules to some extent.

  16. Estimation of Gust Response Factor for a Tall Building Model with 1:1.5 Plan Ratios

    NASA Astrophysics Data System (ADS)

    Sarath Kumar, H.; Selvi Rajan, S.

    2017-08-01

    The purpose of structural analysis and design of structures as per the building codes and its corresponding standers is to ensure the safety of structure under maximum loads and remains functional under service load. The structure which is designed under consideration of codes should also satisfy the durability, economy and aesthetics. The primary purpose of this work is to understand and compare design wind loads according with the Gust Response Factor as per codes of practices. The paper is concerned with the calculation of design wind loads on a rectangular building model (1:300gemetric scale) of size 10cm x 15cm x 70cm with an aspect ratio of 1:1.5:7 at eight different levels over the height under sub-urban terrain category for 00 angle and 900 angle wind incidence. The experiment id conducted in an atmospheric boundary layer wind tunnel facility of CSIR-Structural engineering Research centre, Chennai. The measured pressures are integrated to evaluate mean and RMS (Root, Mean, Square). Further the variation of above mentioned loads and response factor along the heights of the building with respect to sub-urban terrain condition are discussed and summarized in addition, the codal values of various international standards [IS-875 part-3 1987, IS-875 part-3 draft, ASCE-07] have also considered for comparison.

  17. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  18. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  19. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  20. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  1. 41 CFR 102-80.85 - Are Federally owned and leased buildings exempt from State and local code requirements in fire...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... leased buildings exempt from State and local code requirements in fire protection? 102-80.85 Section 102... Fire Prevention State and Local Codes § 102-80.85 Are Federally owned and leased buildings exempt from State and local code requirements in fire protection? Federally owned buildings are generally exempt...

  2. Seismic assessment of Technical Area V (TA-V).

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Medrano, Carlos S.

    The Technical Area V (TA-V) Seismic Assessment Report was commissioned as part of Sandia National Laboratories (SNL) Self Assessment Requirement per DOE O 414.1, Quality Assurance, for seismic impact on existing facilities at Technical Area-V (TA-V). SNL TA-V facilities are located on an existing Uniform Building Code (UBC) Seismic Zone IIB Site within the physical boundary of the Kirtland Air Force Base (KAFB). The document delineates a summary of the existing facilities with their safety-significant structure, system and components, identifies DOE Guidance, conceptual framework, past assessments and the present Geological and Seismic conditions. Building upon the past information and themore » evolution of the new seismic design criteria, the document discusses the potential impact of the new standards and provides recommendations based upon the current International Building Code (IBC) per DOE O 420.1B, Facility Safety and DOE G 420.1-2, Guide for the Mitigation of Natural Phenomena Hazards for DOE Nuclear Facilities and Non-Nuclear Facilities.« less

  3. Utility residential new construction programs: Going beyond the code. A report from the Database on Energy Efficiency Programs (DEEP) Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vine, E.

    Based on an evaluation of 10 residential new construction programs, primarily sponsored by investor-owned utilities in the United States, we find that many of these programs are in dire straits and are in danger of being discontinued because current inclusion of only direct program effects leads to the conclusion that they are not cost-effective. We believe that the cost-effectiveness of residential new construction programs can be improved by: (1) promoting technologies and advanced building design practices that significantly exceed state and federal standards; (2) reducing program marketing costs and developing more effective marketing strategies; (3) recognizing the role of thesemore » programs in increasing compliance with existing state building codes; and (4) allowing utilities to obtain an ``energy-savings credit`` from utility regulators for program spillover (market transformation) impacts. Utilities can also leverage their resources in seizing these opportunities by forming strong and trusting partnerships with the building community and with local and state government.« less

  4. Mitigating shear lag in tall buildings

    NASA Astrophysics Data System (ADS)

    Gaur, Himanshu; Goliya, Ravindra K.

    2015-09-01

    As the height of building increases, effect of shear lag also becomes considerable in the design of high-rise buildings. In this paper, shear lag effect in tall buildings of heights, i.e., 120, 96, 72, 48 and 36 stories of which aspect ratio ranges from 3 to 10 is studied. Tube-in-tube structural system with façade bracing is used for designing the building of height 120 story. It is found that bracing system considerably reduces the shear lag effect and hence increases the building stiffness to withstand lateral loads. Different geometric patterns of bracing system are considered. The best effective geometric configuration of bracing system is concluded in this study. Lateral force, as wind load is applied on the buildings as it is the most dominating lateral force for such heights. Wind load is set as per Indian standard code of practice IS 875 Part-3. For analysis purpose SAP 2000 software program is used.

  5. Building a Better Campus: An Update on Building Codes.

    ERIC Educational Resources Information Center

    Madden, Michael J.

    2002-01-01

    Discusses the implications for higher education institutions in terms of facility planning, design, construction, and renovation of the move from regionally-developed model-building codes to two international sets of codes. Also addresses the new performance-based design option within the codes. (EV)

  6. Extended Policies case

    EIA Publications

    2016-01-01

    The Annual Energy Outlook 2016 (AEO2016) Extended Policies case includes selected policies that go beyond current laws and regulations. Existing tax credits that have scheduled reductions and sunset dates are assumed to remain unchanged through 2040. Other efficiency policies, including corporate average fuel economy standards, appliance standards, and building codes, are expanded beyond current provisions; and the U.S. Environmental Protection Agency (EPA) Clean Power Plan (CPP) regulations that reduce carbon dioxide emissions from electric power generation are tightened after 2030.

  7. A MODEL BUILDING CODE ARTICLE ON FALLOUT SHELTERS WITH RECOMMENDATIONS FOR INCLUSION OF REQUIREMENTS FOR FALLOUT SHELTER CONSTRUCTION IN FOUR NATIONAL MODEL BUILDING CODES.

    ERIC Educational Resources Information Center

    American Inst. of Architects, Washington, DC.

    A MODEL BUILDING CODE FOR FALLOUT SHELTERS WAS DRAWN UP FOR INCLUSION IN FOUR NATIONAL MODEL BUILDING CODES. DISCUSSION IS GIVEN OF FALLOUT SHELTERS WITH RESPECT TO--(1) NUCLEAR RADIATION, (2) NATIONAL POLICIES, AND (3) COMMUNITY PLANNING. FALLOUT SHELTER REQUIREMENTS FOR SHIELDING, SPACE, VENTILATION, CONSTRUCTION, AND SERVICES SUCH AS ELECTRICAL…

  8. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... National Model Building Codes The following documents address the health and safety aspects of buildings... International, Inc., 4051 West Flossmoor Road, Country Club Hills, Illinois 60477. 2 Southern Building Code Congress International, Inc., 900 Montclair Road, Birmingham, Alabama 35213-1206. 3 International...

  9. 7 CFR Exhibit E to Subpart A of... - Voluntary National Model Building Codes

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Voluntary National Model Building Codes E Exhibit E... HOUSING SERVICE, RURAL BUSINESS-COOPERATIVE SERVICE, RURAL UTILITIES SERVICE, AND FARM SERVICE AGENCY... National Model Building Codes The following documents address the health and safety aspects of buildings...

  10. Xenomicrobiology: a roadmap for genetic code engineering.

    PubMed

    Acevedo-Rocha, Carlos G; Budisa, Nediljko

    2016-09-01

    Biology is an analytical and informational science that is becoming increasingly dependent on chemical synthesis. One example is the high-throughput and low-cost synthesis of DNA, which is a foundation for the research field of synthetic biology (SB). The aim of SB is to provide biotechnological solutions to health, energy and environmental issues as well as unsustainable manufacturing processes in the frame of naturally existing chemical building blocks. Xenobiology (XB) goes a step further by implementing non-natural building blocks in living cells. In this context, genetic code engineering respectively enables the re-design of genes/genomes and proteins/proteomes with non-canonical nucleic (XNAs) and amino (ncAAs) acids. Besides studying information flow and evolutionary innovation in living systems, XB allows the development of new-to-nature therapeutic proteins/peptides, new biocatalysts for potential applications in synthetic organic chemistry and biocontainment strategies for enhanced biosafety. In this perspective, we provide a brief history and evolution of the genetic code in the context of XB. We then discuss the latest efforts and challenges ahead for engineering the genetic code with focus on substitutions and additions of ncAAs as well as standard amino acid reductions. Finally, we present a roadmap for the directed evolution of artificial microbes for emancipating rare sense codons that could be used to introduce novel building blocks. The development of such xenomicroorganisms endowed with a 'genetic firewall' will also allow to study and understand the relation between code evolution and horizontal gene transfer. © 2016 The Authors. Microbial Biotechnology published by John Wiley & Sons Ltd and Society for Applied Microbiology.

  11. Potential Job Creation in Rhode Island as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  12. Potential Job Creation in Minnesota as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  13. Potential Job Creation in Tennessee as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  14. Potential Job Creation in Nevada as a Result of Adopting New Residential Building Energy Codes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Scott, Michael J.; Niemeyer, Jackie M.

    Are there advantages to states that adopt the most recent model building energy codes other than saving energy? For example, can the construction activity and energy savings associated with code-compliant housing units become significant sources of job creation for states if new building energy codes are adopted to cover residential construction? , The U.S. Department of Energy (DOE) Building Energy Codes Program (BECP) asked Pacific Northwest National Laboratory (PNNL) to research and ascertain whether jobs would be created in individual states based on their adoption of model building energy codes. Each state in the country is dealing with high levelsmore » of unemployment, so job creation has become a top priority. Many programs have been created to combat unemployment with various degrees of failure and success. At the same time, many states still have not yet adopted the most current versions of the International Energy Conservation Code (IECC) model building energy code, when doing so could be a very effective tool in creating jobs to assist states in recovering from this economic downturn.« less

  15. SAFETY IN THE DESIGN OF SCIENCE LABORATORIES AND BUILDING CODES.

    ERIC Educational Resources Information Center

    HOROWITZ, HAROLD

    THE DESIGN OF COLLEGE AND UNIVERSITY BUILDINGS USED FOR SCIENTIFIC RESEARCH AND EDUCATION IS DISCUSSED IN TERMS OF LABORATORY SAFETY AND BUILDING CODES AND REGULATIONS. MAJOR TOPIC AREAS ARE--(1) SAFETY RELATED DESIGN FEATURES OF SCIENCE LABORATORIES, (2) LABORATORY SAFETY AND BUILDING CODES, AND (3) EVIDENCE OF UNSAFE DESIGN. EXAMPLES EMPHASIZE…

  16. Green School Initiatives. Statements from Hearing of the U.S. Senate, Environment and Public Works Committee, 107th Congress, Second Session.

    ERIC Educational Resources Information Center

    Congress of the U.S., Washington, DC. Senate Committee on Environment and Public Works.

    The Senate's Environmental and Public Works Committee conducted a hearing in October 2002 to assess green school initiatives: environmental standards for schools, school siting in relation to toxic waste sites, and "green" building codes. The committee reviewed activities undertaken by the Environmental Protection Agency's (EPA's) Office…

  17. Comparison of analytical methods for calculation of wind loads

    NASA Technical Reports Server (NTRS)

    Minderman, Donald J.; Schultz, Larry L.

    1989-01-01

    The following analysis is a comparison of analytical methods for calculation of wind load pressures. The analytical methods specified in ASCE Paper No. 3269, ANSI A58.1-1982, the Standard Building Code, and the Uniform Building Code were analyzed using various hurricane speeds to determine the differences in the calculated results. The winds used for the analysis ranged from 100 mph to 125 mph and applied inland from the shoreline of a large open body of water (i.e., an enormous lake or the ocean) a distance of 1500 feet or ten times the height of the building or structure considered. For a building or structure less than or equal to 250 feet in height acted upon by a wind greater than or equal to 115 mph, it was determined that the method specified in ANSI A58.1-1982 calculates a larger wind load pressure than the other methods. For a building or structure between 250 feet and 500 feet tall acted upon by a wind rangind from 100 mph to 110 mph, there is no clear choice of which method to use; for these cases, factors that must be considered are the steady-state or peak wind velocity, the geographic location, the distance from a large open body of water, and the expected design life and its risk factor.

  18. A Comparative Study on Seismic Analysis of Bangladesh National Building Code (BNBC) with Other Building Codes

    NASA Astrophysics Data System (ADS)

    Bari, Md. S.; Das, T.

    2013-09-01

    Tectonic framework of Bangladesh and adjoining areas indicate that Bangladesh lies well within an active seismic zone. The after effect of earthquake is more severe in an underdeveloped and a densely populated country like ours than any other developed countries. Bangladesh National Building Code (BNBC) was first established in 1993 to provide guidelines for design and construction of new structure subject to earthquake ground motions in order to minimize the risk to life for all structures. A revision of BNBC 1993 is undergoing to make this up to date with other international building codes. This paper aims at the comparison of various provisions of seismic analysis as given in building codes of different countries. This comparison will give an idea regarding where our country stands when it comes to safety against earth quake. Primarily, various seismic parameters in BNBC 2010 (draft) have been studied and compared with that of BNBC 1993. Later, both 1993 and 2010 edition of BNBC codes have been compared graphically with building codes of other countries such as National Building Code of India 2005 (NBC-India 2005), American Society of Civil Engineering 7-05 (ASCE 7-05). The base shear/weight ratios have been plotted against the height of the building. The investigation in this paper reveals that BNBC 1993 has the least base shear among all the codes. Factored Base shear values of BNBC 2010 are found to have increased significantly than that of BNBC 1993 for low rise buildings (≤20 m) around the country than its predecessor. Despite revision of the code, BNBC 2010 (draft) still suggests less base shear values when compared to the Indian and American code. Therefore, this increase in factor of safety against the earthquake imposed by the proposed BNBC 2010 code by suggesting higher values of base shear is appreciable.

  19. Comparative study of air-conditioning energy use of four office buildings in China and USA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhou, Xin; Yan, Da; An, Jingjing

    Energy use in buildings has great variability. In order to design and operate low energy buildings as well as to establish building energy codes and standards and effective energy policy, it is crucial to understand and quantify key factors influencing building energy performance. Here, this study investigates air-conditioning (AC) energy use of four office buildings in four locations: Beijing, Taiwan, Hong Kong, and Berkeley. Building simulation was employed to quantify the influences of key factors, including climate, building envelope and occupant behavior. Through simulation of various combinations of the three influencing elements, it is found that climate can lead tomore » AC cooling consumption differences by almost two times, while occupant behavior resulted in the greatest differences (of up to three times) in AC cooling consumption. The influence of occupant behavior on AC energy consumption is not homogeneous. Under similar climates, when the occupant behavior in the building differed, the optimized building envelope design also differed. In conclusion, the optimal building envelope should be determined according to the climate as well as the occupants who use the building.« less

  20. Comparative study of air-conditioning energy use of four office buildings in China and USA

    DOE PAGES

    Zhou, Xin; Yan, Da; An, Jingjing; ...

    2018-04-05

    Energy use in buildings has great variability. In order to design and operate low energy buildings as well as to establish building energy codes and standards and effective energy policy, it is crucial to understand and quantify key factors influencing building energy performance. Here, this study investigates air-conditioning (AC) energy use of four office buildings in four locations: Beijing, Taiwan, Hong Kong, and Berkeley. Building simulation was employed to quantify the influences of key factors, including climate, building envelope and occupant behavior. Through simulation of various combinations of the three influencing elements, it is found that climate can lead tomore » AC cooling consumption differences by almost two times, while occupant behavior resulted in the greatest differences (of up to three times) in AC cooling consumption. The influence of occupant behavior on AC energy consumption is not homogeneous. Under similar climates, when the occupant behavior in the building differed, the optimized building envelope design also differed. In conclusion, the optimal building envelope should be determined according to the climate as well as the occupants who use the building.« less

  1. Review of Punching Shear Behaviour of Flat Slabs Reinforced with FRP Bars

    NASA Astrophysics Data System (ADS)

    Mohamed, Osama A.; Khattab, Rania

    2017-10-01

    Using Fibre Reinforced Polymer (FRP) bars to reinforce two-way concrete slabs can extend the service life, reduce maintenance cost and improve-life cycle cost efficiency. FRP reinforcing bars are more environmentally friendly alternatives to traditional reinforcing steel. Shear behaviour of reinforced concrete structural members is a complex phenomenon that relies on the development of internal load-carrying mechanisms, the magnitude and combination of which is still a subject of research. Many building codes and design standards provide design formulas for estimation of punching shear capacity of FRP reinforced flat slabs. Building code formulas take into account the effects of the axial stiffness of main reinforcement bars, the ratio of the perimeter of the critical section to the slab effective depth, and the slab thickness on the punching shear capacity of two-way slabs reinforced with FRP bars or grids. The goal of this paper is to compare experimental data published in the literature to the equations offered by building codes for the estimation of punching shear capacity of concrete flat slabs reinforced with FRP bars. Emphasis in this paper is on two North American codes, namely, ACI 440.1R-15 and CSA S806-12. The experimental data covered in this paper include flat slabs reinforced with GFRP, BFRP, and CFRP bars. Both ACI 440.1R-15 and CSA S806-12 are shown to be in good agreement with test results in terms of predicting the punching shear capacity.

  2. National Tribal Building Codes Summit

    EPA Pesticide Factsheets

    National Tribal Building Codes summit statement developed to support tribes interested in adopting green and culturally-appropriate building systems to ensure safe, sustainable, affordable, and culturally-appropriate buildings on tribal lands.

  3. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    2017-01-01

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less

  4. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lstiburek, Joseph

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamilymore » units that satisfies the requirements of ASHRAE 62.2-2016.« less

  5. Technology change and energy consumption: A comparison of residential subdivisions

    NASA Astrophysics Data System (ADS)

    Nieves, L. A.; Nieves, A. L.

    The energy savings in residential buildings likely to result from implementation of the building energy performance standards (BEPS) were assessed. The goals were to: compare energy use in new homes designed to meet or exceed BEPS levels of energy efficiency with that in similar but older homes designed to meet conventional building codes, and to survey the home owners regarding their energy conservation attitudes and behaviors and to ascertain the degree to which conservation attitudes and behaviors are related to residential energy use. The consumer demand theory which provides the framework for the empirical analysis is presented. The sample residences are described and the data collection method discussed. The definition and measurement of major variables are presented.

  6. Preserving Envelope Efficiency in Performance Based Code Compliance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thornton, Brian A.; Sullivan, Greg P.; Rosenberg, Michael I.

    2015-06-20

    The City of Seattle 2012 Energy Code (Seattle 2014), one of the most progressive in the country, is under revision for its 2015 edition. Additionally, city personnel participate in the development of the next generation of the Washington State Energy Code and the International Energy Code. Seattle has pledged carbon neutrality by 2050 including buildings, transportation and other sectors. The United States Department of Energy (DOE), through Pacific Northwest National Laboratory (PNNL) provided technical assistance to Seattle in order to understand the implications of one potential direction for its code development, limiting trade-offs of long-lived building envelope components less stringentmore » than the prescriptive code envelope requirements by using better-than-code but shorter-lived lighting and heating, ventilation, and air-conditioning (HVAC) components through the total building performance modeled energy compliance path. Weaker building envelopes can permanently limit building energy performance even as lighting and HVAC components are upgraded over time, because retrofitting the envelope is less likely and more expensive. Weaker building envelopes may also increase the required size, cost and complexity of HVAC systems and may adversely affect occupant comfort. This report presents the results of this technical assistance. The use of modeled energy code compliance to trade-off envelope components with shorter-lived building components is not unique to Seattle and the lessons and possible solutions described in this report have implications for other jurisdictions and energy codes.« less

  7. A Standard-Driven Data Dictionary for Data Harmonization of Heterogeneous Datasets in Urban Geological Information Systems

    NASA Astrophysics Data System (ADS)

    Liu, G.; Wu, C.; Li, X.; Song, P.

    2013-12-01

    The 3D urban geological information system has been a major part of the national urban geological survey project of China Geological Survey in recent years. Large amount of multi-source and multi-subject data are to be stored in the urban geological databases. There are various models and vocabularies drafted and applied by industrial companies in urban geological data. The issues such as duplicate and ambiguous definition of terms and different coding structure increase the difficulty of information sharing and data integration. To solve this problem, we proposed a national standard-driven information classification and coding method to effectively store and integrate urban geological data, and we applied the data dictionary technology to achieve structural and standard data storage. The overall purpose of this work is to set up a common data platform to provide information sharing service. Research progresses are as follows: (1) A unified classification and coding method for multi-source data based on national standards. Underlying national standards include GB 9649-88 for geology and GB/T 13923-2006 for geography. Current industrial models are compared with national standards to build a mapping table. The attributes of various urban geological data entity models are reduced to several categories according to their application phases and domains. Then a logical data model is set up as a standard format to design data file structures for a relational database. (2) A multi-level data dictionary for data standardization constraint. Three levels of data dictionary are designed: model data dictionary is used to manage system database files and enhance maintenance of the whole database system; attribute dictionary organizes fields used in database tables; term and code dictionary is applied to provide a standard for urban information system by adopting appropriate classification and coding methods; comprehensive data dictionary manages system operation and security. (3) An extension to system data management function based on data dictionary. Data item constraint input function is making use of the standard term and code dictionary to get standard input result. Attribute dictionary organizes all the fields of an urban geological information database to ensure the consistency of term use for fields. Model dictionary is used to generate a database operation interface automatically with standard semantic content via term and code dictionary. The above method and technology have been applied to the construction of Fuzhou Urban Geological Information System, South-East China with satisfactory results.

  8. Lidar performance analysis

    NASA Technical Reports Server (NTRS)

    Spiers, Gary D.

    1994-01-01

    Section 1 details the theory used to build the lidar model, provides results of using the model to evaluate AEOLUS design instrument designs, and provides snapshots of the visual appearance of the coded model. Appendix A contains a Fortran program to calculate various forms of the refractive index structure function. This program was used to determine the refractive index structure function used in the main lidar simulation code. Appendix B contains a memo on the optimization of the lidar telescope geometry for a line-scan geometry. Appendix C contains the code for the main lidar simulation and brief instruction on running the code. Appendix D contains a Fortran code to calculate the maximum permissible exposure for the eye from the ANSI Z136.1-1992 eye safety standards. Appendix E contains a paper on the eye safety analysis of a space-based coherent lidar presented at the 7th Coherent Laser Radar Applications and Technology Conference, Paris, France, 19-23 July 1993.

  9. Development of probabilistic multimedia multipathway computer codes.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, C.; LePoire, D.; Gnanapragasam, E.

    2002-01-01

    The deterministic multimedia dose/risk assessment codes RESRAD and RESRAD-BUILD have been widely used for many years for evaluation of sites contaminated with residual radioactive materials. The RESRAD code applies to the cleanup of sites (soils) and the RESRAD-BUILD code applies to the cleanup of buildings and structures. This work describes the procedure used to enhance the deterministic RESRAD and RESRAD-BUILD codes for probabilistic dose analysis. A six-step procedure was used in developing default parameter distributions and the probabilistic analysis modules. These six steps include (1) listing and categorizing parameters; (2) ranking parameters; (3) developing parameter distributions; (4) testing parameter distributionsmore » for probabilistic analysis; (5) developing probabilistic software modules; and (6) testing probabilistic modules and integrated codes. The procedures used can be applied to the development of other multimedia probabilistic codes. The probabilistic versions of RESRAD and RESRAD-BUILD codes provide tools for studying the uncertainty in dose assessment caused by uncertain input parameters. The parameter distribution data collected in this work can also be applied to other multimedia assessment tasks and multimedia computer codes.« less

  10. 28 CFR 36.606 - Effect of certification.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes... the question of whether equipment in a building built according to the code satisfies the Act's... buildings and facilities that comply with the certified code. A submitting official may reapply for...

  11. 28 CFR 36.606 - Effect of certification.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes... the question of whether equipment in a building built according to the code satisfies the Act's... buildings and facilities that comply with the certified code. A submitting official may reapply for...

  12. 28 CFR 36.606 - Effect of certification.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes... the question of whether equipment in a building built according to the code satisfies the Act's... buildings and facilities that comply with the certified code. A submitting official may reapply for...

  13. 28 CFR 36.606 - Effect of certification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes... the question of whether equipment in a building built according to the code satisfies the Act's... buildings and facilities that comply with the certified code. A submitting official may reapply for...

  14. Compiling standardized information from clinical practice: using content analysis and ICF Linking Rules in a goal-oriented youth rehabilitation program.

    PubMed

    Lustenberger, Nadia A; Prodinger, Birgit; Dorjbal, Delgerjargal; Rubinelli, Sara; Schmitt, Klaus; Scheel-Sailer, Anke

    2017-09-23

    To illustrate how routinely written narrative admission and discharge reports of a rehabilitation program for eight youths with chronic neurological health conditions can be transformed to the International Classification of Functioning, Disability and Health. First, a qualitative content analysis was conducted by building meaningful units with text segments assigned of the reports to the five elements of the Rehab-Cycle ® : goal; assessment; assignment; intervention; evaluation. Second, the meaningful units were then linked to the ICF using the refined ICF Linking Rules. With the first step of transformation, the emphasis of the narrative reports changed to a process oriented interdisciplinary layout, revealing three thematic blocks of goals: mobility, self-care, mental, and social functions. The linked 95 unique ICF codes could be grouped in clinically meaningful goal-centered ICF codes. Between the two independent linkers, the agreement rate was improved after complementing the rules with additional agreements. The ICF Linking Rules can be used to compile standardized health information from narrative reports if prior structured. The process requires time and expertise. To implement the ICF into common practice, the findings provide the starting point for reporting rehabilitation that builds upon existing practice and adheres to international standards. Implications for Rehabilitation This study provides evidence that routinely collected health information from rehabilitation practice can be transformed to the International Classification of Functioning, Disability and Health by using the "ICF Linking Rules", however, this requires time and expertise. The Rehab-Cycle ® , including assessments, assignments, goal setting, interventions and goal evaluation, serves as feasible framework for structuring this rehabilitation program and ensures that the complexity of local practice is appropriately reflected. The refined "ICF Linking Rules" lead to a standardized transformation process of narrative text and thus a higher quality with increased transparency. As a next step, the resulting format of goal codes supplemented by goal-clarifying codes could be validated to strengthen the implementation of the International Classification of Functioning, Disability and Health into rehabilitation routine by respecting the variety of clinical practice.

  15. Building a portable data and information interoperability infrastructure-framework for a standard Taiwan Electronic Medical Record Template.

    PubMed

    Jian, Wen-Shan; Hsu, Chien-Yeh; Hao, Te-Hui; Wen, Hsyien-Chia; Hsu, Min-Huei; Lee, Yen-Liang; Li, Yu-Chuan; Chang, Polun

    2007-11-01

    Traditional electronic health record (EHR) data are produced from various hospital information systems. They could not have existed independently without an information system until the incarnation of XML technology. The interoperability of a healthcare system can be divided into two dimensions: functional interoperability and semantic interoperability. Currently, no single EHR standard exists that provides complete EHR interoperability. In order to establish a national EHR standard, we developed a set of local EHR templates. The Taiwan Electronic Medical Record Template (TMT) is a standard that aims to achieve semantic interoperability in EHR exchanges nationally. The TMT architecture is basically composed of forms, components, sections, and elements. Data stored in the elements which can be referenced by the code set, data type, and narrative block. The TMT was established with the following requirements in mind: (1) transformable to international standards; (2) having a minimal impact on the existing healthcare system; (3) easy to implement and deploy, and (4) compliant with Taiwan's current laws and regulations. The TMT provides a basis for building a portable, interoperable information infrastructure for EHR exchange in Taiwan.

  16. Evaluation of seismic design spectrum based on UHS implementing fourth-generation seismic hazard maps of Canada

    NASA Astrophysics Data System (ADS)

    Ahmed, Ali; Hasan, Rafiq; Pekau, Oscar A.

    2016-12-01

    Two recent developments have come into the forefront with reference to updating the seismic design provisions for codes: (1) publication of new seismic hazard maps for Canada by the Geological Survey of Canada, and (2) emergence of the concept of new spectral format outdating the conventional standardized spectral format. The fourth -generation seismic hazard maps are based on enriched seismic data, enhanced knowledge of regional seismicity and improved seismic hazard modeling techniques. Therefore, the new maps are more accurate and need to incorporate into the Canadian Highway Bridge Design Code (CHBDC) for its next edition similar to its building counterpart National Building Code of Canada (NBCC). In fact, the code writers expressed similar intentions with comments in the commentary of CHBCD 2006. During the process of updating codes, NBCC, and AASHTO Guide Specifications for LRFD Seismic Bridge Design, American Association of State Highway and Transportation Officials, Washington (2009) lowered the probability level from 10 to 2% and 10 to 5%, respectively. This study has brought five sets of hazard maps corresponding to 2%, 5% and 10% probability of exceedance in 50 years developed by the GSC under investigation. To have a sound statistical inference, 389 Canadian cities are selected. This study shows the implications of the changes of new hazard maps on the design process (i.e., extent of magnification or reduction of the design forces).

  17. Continuation of research into language concepts for the mission support environment: Source code

    NASA Technical Reports Server (NTRS)

    Barton, Timothy J.; Ratner, Jeremiah M.

    1991-01-01

    Research into language concepts for the Mission Control Center is presented. A computer code for source codes is presented. The file contains the routines which allow source code files to be created and compiled. The build process assumes that all elements and the COMP exist in the current directory. The build process places as much code generation as possible on the preprocessor as possible. A summary is given of the source files as used and/or manipulated by the build routine.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael; Jonlin, Duane; Nadel, Steven

    Today’s building energy codes focus on prescriptive requirements for features of buildings that are directly controlled by the design and construction teams and verifiable by municipal inspectors. Although these code requirements have had a significant impact, they fail to influence a large slice of the building energy use pie – including not only miscellaneous plug loads, cooking equipment and commercial/industrial processes, but the maintenance and optimization of the code-mandated systems as well. Currently, code compliance is verified only through the end of construction, and there are no limits or consequences for the actual energy use in an occupied building. Inmore » the future, our suite of energy regulations will likely expand to include building efficiency, energy use or carbon emission budgets over their full life cycle. Intelligent building systems, extensive renewable energy, and a transition from fossil fuel to electric heating systems will likely be required to meet ultra-low-energy targets. This paper lays out the authors’ perspectives on how buildings may evolve over the course of the 21st century and the roles that codes and regulations will play in shaping those buildings of the future.« less

  19. 41 CFR 102-76.10 - What basic design and construction policy governs Federal agencies?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    .... (c) Follow nationally recognized model building codes and other applicable nationally recognized codes that govern Federal construction to the maximum extent feasible and consider local building code requirements. (See 40 U.S.C. 3310 and 3312.) (d) Design Federal buildings to have a long life expectancy and...

  20. Residential Building Energy Code Field Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    R. Bartlett, M. Halverson, V. Mendon, J. Hathaway, Y. Xie

    This document presents a methodology for assessing baseline energy efficiency in new single-family residential buildings and quantifying related savings potential. The approach was developed by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) Building Energy Codes Program with the objective of assisting states as they assess energy efficiency in residential buildings and implementation of their building energy codes, as well as to target areas for improvement through energy codes and broader energy-efficiency programs. It is also intended to facilitate a consistent and replicable approach to research studies of this type and establish a transparent data setmore » to represent baseline construction practices across U.S. states.« less

  1. PETSc Users Manual Revision 3.7

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balay, Satish; Abhyankar, S.; Adams, M.

    This manual describes the use of PETSc for the numerical solution of partial differential equations and related problems on high-performance computers. The Portable, Extensible Toolkit for Scientific Computation (PETSc) is a suite of data structures and routines that provide the building blocks for the implementation of large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all message-passing communication.

  2. PETSc Users Manual Revision 3.8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Balay, S.; Abhyankar, S.; Adams, M.

    This manual describes the use of PETSc for the numerical solution of partial differential equations and related problems on high-performance computers. The Portable, Extensible Toolkit for Scientific Computation (PETSc) is a suite of data structures and routines that provide the building blocks for the implementation of large-scale application codes on parallel (and serial) computers. PETSc uses the MPI standard for all message-passing communication.

  3. 76 FR 13101 - Building Energy Codes Program: Presenting and Receiving Comments to DOE Proposed Changes to the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-10

    .... The IgCC is intended to provide a green model building code provisions for new and existing commercial... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket No. EERE-2011-BT-BC-0009] Building Energy Codes Program: Presenting and Receiving Comments to DOE Proposed Changes to the International Green Construction...

  4. 44 CFR 71.4 - Documentation.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...

  5. 44 CFR 71.4 - Documentation.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...

  6. 44 CFR 71.4 - Documentation.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...

  7. 44 CFR 71.4 - Documentation.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...

  8. 44 CFR 71.4 - Documentation.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... evidence that the structure was not in compliance with the building code at the time it was built; and (2... evidence that the structure was not in compliance with the building code at the time it was built; and (2... structure and found no evidence that the structure was not in compliance with the building code at the time...

  9. A simplified building airflow model for agent concentration prediction.

    PubMed

    Jacques, David R; Smith, David A

    2010-11-01

    A simplified building airflow model is presented that can be used to predict the spread of a contaminant agent from a chemical or biological attack. If the dominant means of agent transport throughout the building is an air-handling system operating at steady-state, a linear time-invariant (LTI) model can be constructed to predict the concentration in any room of the building as a result of either an internal or external release. While the model does not capture weather-driven and other temperature-driven effects, it is suitable for concentration predictions under average daily conditions. The model is easily constructed using information that should be accessible to a building manager, supplemented with assumptions based on building codes and standard air-handling system design practices. The results of the model are compared with a popular multi-zone model for a simple building and are demonstrated for building examples containing one or more air-handling systems. The model can be used for rapid concentration prediction to support low-cost placement strategies for chemical and biological detection sensors.

  10. Faunus: An object oriented framework for molecular simulation

    PubMed Central

    Lund, Mikael; Trulsson, Martin; Persson, Björn

    2008-01-01

    Background We present a C++ class library for Monte Carlo simulation of molecular systems, including proteins in solution. The design is generic and highly modular, enabling multiple developers to easily implement additional features. The statistical mechanical methods are documented by extensive use of code comments that – subsequently – are collected to automatically build a web-based manual. Results We show how an object oriented design can be used to create an intuitively appealing coding framework for molecular simulation. This is exemplified in a minimalistic C++ program that can calculate protein protonation states. We further discuss performance issues related to high level coding abstraction. Conclusion C++ and the Standard Template Library (STL) provide a high-performance platform for generic molecular modeling. Automatic generation of code documentation from inline comments has proven particularly useful in that no separate manual needs to be maintained. PMID:18241331

  11. 24 CFR 200.926c - Model code provisions for use in partially accepted code jurisdictions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... jurisdictions. If a lender or other interested party is notified that a State or local building code has been... in accordance with the applicable State or local building code, plus those additional requirements... 24 Housing and Urban Development 2 2014-04-01 2014-04-01 false Model code provisions for use in...

  12. 24 CFR 200.926c - Model code provisions for use in partially accepted code jurisdictions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... jurisdictions. If a lender or other interested party is notified that a State or local building code has been... in accordance with the applicable State or local building code, plus those additional requirements... 24 Housing and Urban Development 2 2013-04-01 2013-04-01 false Model code provisions for use in...

  13. 24 CFR 200.926c - Model code provisions for use in partially accepted code jurisdictions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... jurisdictions. If a lender or other interested party is notified that a State or local building code has been... in accordance with the applicable State or local building code, plus those additional requirements... 24 Housing and Urban Development 2 2012-04-01 2012-04-01 false Model code provisions for use in...

  14. Effect of fire-induced damage on the uniaxial strength characteristics of solid timber: A numerical study

    NASA Astrophysics Data System (ADS)

    Hopkin, D. J.; El-Rimawi, J.; Lennon, T.; Silberschmidt, V. V.

    2011-07-01

    The advent of the structural Eurocodes has allowed civil engineers to be more creative in the design of structures exposed to fire. Rather than rely upon regulatory guidance and prescriptive methods engineers are now able to use such codes to design buildings on the basis of credible design fires rather than accepted unrealistic standard-fire time-temperature curves. Through this process safer and more efficient structural designs are achievable. The key development in enabling performance-based fire design is the emergence of validated numerical models capable of predicting the mechanical response of a whole building or sub-assemblies at elevated temperature. In such a way, efficiency savings have been achieved in the design of steel, concrete and composite structures. However, at present, due to a combination of limited fundamental research and restrictions in the UK National Annex to the timber Eurocode, the design of fire-exposed timber structures using numerical modelling techniques is not generally undertaken. The 'fire design' of timber structures is covered in Eurocode 5 part 1.2 (EN 1995-1-2). In this code there is an advanced calculation annex (Annex B) intended to facilitate the implementation of numerical models in the design of fire-exposed timber structures. The properties contained in the code can, at present, only be applied to standard-fire exposure conditions. This is due to existing limitations related to the available thermal properties which are only valid for standard fire exposure. In an attempt to overcome this barrier the authors have proposed a 'modified conductivity model' (MCM) for determining the temperature of timber structural elements during the heating phase of non-standard fires. This is briefly outlined in this paper. In addition, in a further study, the MCM has been implemented in a coupled thermo-mechanical analysis of uniaxially loaded timber elements exposed to non-standard fires. The finite element package DIANA was adopted with plane-strain elements assuming two-dimensional heat flow. The resulting predictions of failure time for given levels of load are discussed and compared with the simplified 'effective cross section' method presented in EN 1995-1-2.

  15. Automating RPM Creation from a Source Code Repository

    DTIC Science & Technology

    2012-02-01

    apps/usr --with- libpq=/apps/ postgres make rm -rf $RPM_BUILD_ROOT umask 0077 mkdir -p $RPM_BUILD_ROOT/usr/local/bin mkdir -p $RPM_BUILD_ROOT...from a source code repository. %pre %prep %setup %build ./autogen.sh ; ./configure --with-db=/apps/db --with-libpq=/apps/ postgres make

  16. Performance-based building codes: a call for injury prevention indicators that bridge health and building sectors.

    PubMed

    Edwards, N

    2008-10-01

    The international introduction of performance-based building codes calls for a re-examination of indicators used to monitor their implementation. Indicators used in the building sector have a business orientation, target the life cycle of buildings, and guide asset management. In contrast, indicators used in the health sector focus on injury prevention, have a behavioural orientation, lack specificity with respect to features of the built environment, and do not take into account patterns of building use or building longevity. Suggestions for metrics that bridge the building and health sectors are discussed. The need for integrated surveillance systems in health and building sectors is outlined. It is time to reconsider commonly used epidemiological indicators in the field of injury prevention and determine their utility to address the accountability requirements of performance-based codes.

  17. A commercial building energy standard for Mexico

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huang, J.; Warner, J.L.; Wiel, S.

    1998-07-01

    Beginning in 1992, the Comission Nacional de Ahorro de Energia (CONAE), or Mexican National Commission for Energy Conservation, developed a national energy standard for commercial buildings, with assistance from USAID and LBNL. The first complete draft of the standard was released for public review in mid-1995. To promote public acceptance of the standard, CONAE held advisory meetings with architects, engineers, and utility representatives, and organized pubic workshops presented by the authors, with support from USAID. In response to industry comments, the standard was revised in late 1997 and is currently under review by CONAE. It is anticipated that the revisedmore » draft will be released again for final public comments in the summer of 1998. The standard will become law one year after it is finalized by CONAE and published in the federal government record. Since Mexico consists of cooling-dominated climates, the standard emphasizes energy-efficient envelope design to control solar and conductive heat gains. The authors extended DOE-2 simulation results for four climates to all of Mexico through regression analysis. Based on these results, they developed a simplified custom budget calculation approach. To facilitate the method's use, a calculation template was devised in a spreadsheet program and distributed to the public. CONAE anticipates that local engineering associations will use this spreadsheet to administer code compliance.« less

  18. Functional assessment and performance evaluation for assistive robotic manipulators: Literature review.

    PubMed

    Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A

    2013-07-01

    The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System - PITTCat. Twenty relevant studies were identified. Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators.

  19. Beyond standard model calculations with Sherpa

    DOE PAGES

    Höche, Stefan; Kuttimalai, Silvan; Schumann, Steffen; ...

    2015-03-24

    We present a fully automated framework as part of the Sherpa event generator for the computation of tree-level cross sections in beyond Standard Model scenarios, making use of model information given in the Universal FeynRules Output format. Elementary vertices are implemented into C++ code automatically and provided to the matrix-element generator Comix at runtime. Widths and branching ratios for unstable particles are computed from the same building blocks. The corresponding decays are simulated with spin correlations. Parton showers, QED radiation and hadronization are added by Sherpa, providing a full simulation of arbitrary BSM processes at the hadron level.

  20. Beyond standard model calculations with Sherpa.

    PubMed

    Höche, Stefan; Kuttimalai, Silvan; Schumann, Steffen; Siegert, Frank

    We present a fully automated framework as part of the Sherpa event generator for the computation of tree-level cross sections in Beyond Standard Model scenarios, making use of model information given in the Universal FeynRules Output format. Elementary vertices are implemented into C++ code automatically and provided to the matrix-element generator Comix at runtime. Widths and branching ratios for unstable particles are computed from the same building blocks. The corresponding decays are simulated with spin correlations. Parton showers, QED radiation and hadronization are added by Sherpa, providing a full simulation of arbitrary BSM processes at the hadron level.

  1. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Springer, David; German, Alea

    Building cost-effective, high-performance homes that provide superior comfort, health, and durability is the goal of the U.S. Department of Energy’s (DOE’s) Zero Energy Ready Home (ZERH) program. Building America research and other innovative programs throughout the country have addressed many of the technical challenges of building to the ZERH standard. The cost-effectiveness of measure packages that result in 30% source energy savings compared to a code-compliant home have been demonstrated. However, additional challenges remain, particularly with respect to convincing production builders of the strong business case for ZERH. The Alliance for Residential Building Innovation (ARBI) team believes that the keysmore » to successfully engaging builders and developers in the California market are to help them leverage development agreement requirements, code compliance requirements, incentives, and competitive market advantages of ZERH certification, and navigate through this process. A primary objective of this project was to gain a highly visible foothold for residential buildings that are built to the DOE ZERH specification that can be used to encourage participation by other California builders. This report briefly describes two single-family homes that were ZERH certified and focuses on the experience of working with developer Mutual Housing on a 62-unit multifamily community at the Spring Lake subdivision in Woodland, California. The Spring Lake project is expected to be the first ZERH-certified multifamily project in the country. This report discusses the challenges encountered, lessons learned, and how obstacles were overcome.« less

  2. Child Care Services and the NYS Uniform Fire Prevention and Building Code: A Building Code Examination of Child Day Care Services Which Are Regulated by the NYS Department of Social Services with Particular Attention to Day Care Centers and the Role of the Local Authority Having Jurisdiction.

    ERIC Educational Resources Information Center

    New York State Div. of Code Enforcement and Administration, Albany.

    This course manual details the Uniform Fire Prevention and Building Code of New York State and how it affects child care services, particularly day care centers. The sections of the manual, each detailing a part of the code, are: (1) Introduction, Scope, Registration, and Definitions and Facilities Regulated by the New York Department of Social…

  3. Probabilistic Seismic Hazard Assessment for Iraq

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Onur, Tuna; Gok, Rengin; Abdulnaby, Wathiq

    Probabilistic Seismic Hazard Assessments (PSHA) form the basis for most contemporary seismic provisions in building codes around the world. The current building code of Iraq was published in 1997. An update to this edition is in the process of being released. However, there are no national PSHA studies in Iraq for the new building code to refer to for seismic loading in terms of spectral accelerations. As an interim solution, the new draft building code was considering to refer to PSHA results produced in the late 1990s as part of the Global Seismic Hazard Assessment Program (GSHAP; Giardini et al.,more » 1999). However these results are: a) more than 15 years outdated, b) PGA-based only, necessitating rough conversion factors to calculate spectral accelerations at 0.3s and 1.0s for seismic design, and c) at a probability level of 10% chance of exceedance in 50 years, not the 2% that the building code requires. Hence there is a pressing need for a new, updated PSHA for Iraq.« less

  4. Building Energy Efficiency in India: Compliance Evaluation of Energy Conservation Building Code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Evans, Meredydd; Delgado, Alison

    India is experiencing unprecedented construction boom. The country doubled its floorspace between 2001 and 2005 and is expected to add 35 billion m2 of new buildings by 2050. Buildings account for 35% of total final energy consumption in India today, and building energy use is growing at 8% annually. Studies have shown that carbon policies will have little effect on reducing building energy demand. Chaturvedi et al. predicted that, if there is no specific sectoral policies to curb building energy use, final energy demand of the Indian building sector will grow over five times by the end of this century,more » driven by rapid income and population growth. The growing energy demand in buildings is accompanied by a transition from traditional biomass to commercial fuels, particularly an increase in electricity use. This also leads to a rapid increase in carbon emissions and aggravates power shortage in India. Growth in building energy use poses challenges to the Indian government. To curb energy consumption in buildings, the Indian government issued the Energy Conservation Building Code (ECBC) in 2007, which applies to commercial buildings with a connected load of 100 kW or 120kVA. It is predicted that the implementation of ECBC can help save 25-40% of energy, compared to reference buildings without energy-efficiency measures. However, the impact of ECBC depends on the effectiveness of its enforcement and compliance. Currently, the majority of buildings in India are not ECBC-compliant. The United Nations Development Programme projected that code compliance in India would reach 35% by 2015 and 64% by 2017. Whether the projected targets can be achieved depends on how the code enforcement system is designed and implemented. Although the development of ECBC lies in the hands of the national government – the Bureau of Energy Efficiency under the Ministry of Power, the adoption and implementation of ECBC largely relies on state and local governments. Six years after ECBC’s enactment, only two states and one territory out of 35 Indian states and union territories formally adopted ECBC and six additional states are in the legislative process of approving ECBC. There are several barriers that slow down the process. First, stakeholders, such as architects, developers, and state and local governments, lack awareness of building energy efficiency, and do not have enough capacity and resources to implement ECBC. Second, institution for implementing ECBC is not set up yet; ECBC is not included in local building by-laws or incorporated into the building permit process. Third, there is not a systematic approach to measuring and verifying compliance and energy savings, and thus the market does not have enough confidence in ECBC. Energy codes achieve energy savings only when projects comply with codes, yet only few countries measure compliance consistently and periodic checks often indicate poor compliance in many jurisdictions. China and the U.S. appear to be two countries with comprehensive systems in code enforcement and compliance The United States recently developed methodologies measuring compliance with building energy codes at the state level. China has an annual survey investigating code compliance rate at the design and construction stages in major cities. Like many developing countries, India has only recently begun implementing an energy code and would benefit from international experience on code compliance. In this paper, we examine lessons learned from the U.S. and China on compliance assessment and how India can apply these lessons to develop its own compliance evaluation approach. This paper also provides policy suggestions to national, state, and local governments to improve compliance and speed up ECBC implementation.« less

  5. Inclusive domestic violence standards: strategies to improve interventions for women with disabilities?

    PubMed

    Healey, Lucy; Humphreys, Cathy; Howe, Keran

    2013-01-01

    Women with disabilities experience violence at greater rates than other women, yet their access to domestic violence services is more limited. This limitation is mirrored in domestic violence sector standards, which often fail to include the specific issues for women with disabilities. This article has a dual focus: to outline a set of internationally transferrable standards for inclusive practice with women with disabilities affected by domestic violence; and report on the results of a documentary analysis of domestic violence service standards, codes of practice, and practice guidelines. It draws on the Building the Evidence (BtE) research and advocacy project in Victoria, Australia in which a matrix tool was developed to identify minimum standards to support the inclusion of women with disabilities in existing domestic violence sector standards. This tool is designed to interrogate domestic violence sector standards for their attention to women with disabilities.

  6. Building an open-source robotic stereotaxic instrument.

    PubMed

    Coffey, Kevin R; Barker, David J; Ma, Sisi; West, Mark O

    2013-10-29

    This protocol includes the designs and software necessary to upgrade an existing stereotaxic instrument to a robotic (CNC) stereotaxic instrument for around $1,000 (excluding a drill), using industry standard stepper motors and CNC controlling software. Each axis has variable speed control and may be operated simultaneously or independently. The robot's flexibility and open coding system (g-code) make it capable of performing custom tasks that are not supported by commercial systems. Its applications include, but are not limited to, drilling holes, sharp edge craniotomies, skull thinning, and lowering electrodes or cannula. In order to expedite the writing of g-coding for simple surgeries, we have developed custom scripts that allow individuals to design a surgery with no knowledge of programming. However, for users to get the most out of the motorized stereotax, it would be beneficial to be knowledgeable in mathematical programming and G-Coding (simple programming for CNC machining). The recommended drill speed is greater than 40,000 rpm. The stepper motor resolution is 1.8°/Step, geared to 0.346°/Step. A standard stereotax has a resolution of 2.88 μm/step. The maximum recommended cutting speed is 500 μm/sec. The maximum recommended jogging speed is 3,500 μm/sec. The maximum recommended drill bit size is HP 2.

  7. Improving building energy efficiency in India: State-level analysis of building energy efficiency policies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Tan, Qing; Evans, Meredydd

    India is expected to add 40 billion m2 of new buildings till 2050. Buildings are responsible for one third of India’s total energy consumption today and building energy use is expected to continue growing driven by rapid income and population growth. The implementation of the Energy Conservation Building Code (ECBC) is one of the measures to improve building energy efficiency. Using the Global Change Assessment Model, this study assesses growth in the buildings sector and impacts of building energy policies in Gujarat, which would help the state adopt ECBC and expand building energy efficiency programs. Without building energy policies, buildingmore » energy use in Gujarat would grow by 15 times in commercial buildings and 4 times in urban residential buildings between 2010 and 2050. ECBC improves energy efficiency in commercial buildings and could reduce building electricity use in Gujarat by 20% in 2050, compared to the no policy scenario. Having energy codes for both commercial and residential buildings could result in additional 10% savings in electricity use. To achieve these intended savings, it is critical to build capacity and institution for robust code implementation.« less

  8. 28 CFR 36.601 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.601... means a State law or local building code or similar ordinance, or part thereof, that establishes... designee. Certification of equivalency means a final certification that a code meets or exceeds the minimum...

  9. 28 CFR 36.601 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.601... means a State law or local building code or similar ordinance, or part thereof, that establishes... designee. Certification of equivalency means a final certification that a code meets or exceeds the minimum...

  10. 28 CFR 36.601 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.601... means a State law or local building code or similar ordinance, or part thereof, that establishes... designee. Certification of equivalency means a final certification that a code meets or exceeds the minimum...

  11. Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    ARBI

    2014-09-01

    The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared tomore » the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.« less

  12. Development of photovoltaic array and module safety requirements

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Safety requirements for photovoltaic module and panel designs and configurations likely to be used in residential, intermediate, and large-scale applications were identified and developed. The National Electrical Code and Building Codes were reviewed with respect to present provisions which may be considered to affect the design of photovoltaic modules. Limited testing, primarily in the roof fire resistance field was conducted. Additional studies and further investigations led to the development of a proposed standard for safety for flat-plate photovoltaic modules and panels. Additional work covered the initial investigation of conceptual approaches and temporary deployment, for concept verification purposes, of a differential dc ground-fault detection circuit suitable as a part of a photovoltaic array safety system.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Evans, Meredydd; Shi, Qing

    China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies onmore » building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components. This chapter examines insulation in walls and roofs; efficient windows and doors; heating, air conditioning and controls; and lighting. These markets have seen significant growth because of the strength of the construction sector but also the specific policies that require and promote efficient building components. At the same time, as requirements have become more stringent, there has been fierce competition, and quality has at time suffered, which in turn has created additional challenges. Next we examine existing buildings in chapter four. China has many Soviet-style, inefficient buildings built before stringent requirements for efficiency were more widely enforced. As a result, there are several specific market opportunities related to retrofits. These fall into two or three categories. First, China now has a code for retrofitting residential buildings in the north. Local governments have targets of the number of buildings they must retrofit each year, and they help finance the changes. The requirements focus on insulation, windows, and heat distribution. Second, the Chinese government recently decided to increase the scale of its retrofits of government and state-owned buildings. It hopes to achieve large scale changes through energy service contracts, which creates an opportunity for energy service companies. Third, there is also a small but growing trend to apply energy service contracts to large commercial and residential buildings. This report assesses the impacts of China’s policies on building energy efficiency. By examining the existing literature and interviewing stakeholders from the public, academic, and private sectors, the report seeks to offer an in-depth insights of the opportunities and barriers for major market segments related to building energy efficiency. The report also discusses trends in building energy use, policies promoting building energy efficiency, and energy performance contracting for public building retrofits.« less

  14. Building a Foundation for the Implementation of an Enterprise Architecture for the Argentinian Army

    DTIC Science & Technology

    2016-06-01

    foundation for execution, information technology, chief information officer , public administration 15. NUMBER OF PAGES 93 16. PRICE CODE 17. SECURITY...effectively implement IT standardization in the Argentinian Army, the role of Chief Information Officer (CIO) has to be created. The term was introduced...organizations, this is the role of the Chief Information Officer (CIO). The Army should appoint this position and assign responsibility and resources to it

  15. LDDX: A High Efficiency Air Conditioner for DOD Buildings

    DTIC Science & Technology

    2017-02-01

    Defense. Page Intentionally Left Blank REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 Public reporting burden for this collection of...information if it does not display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM...OF RESPONSIBLE PERSON a. REPORT b. ABSTRACT c. THIS PAGE 93 19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Rev. 8-98) Prescribed by

  16. Debris Hazards Due to Overloaded Conventional Construction Facades

    DTIC Science & Technology

    2015-12-01

    NAME OF RESPONSIBLE PERSON a. REPORT b. ABSTRACT c. THIS PAGE 19b. TELEPHONE NUMBER (include area code) Standard Form 298 (Re . 8...Park, CA, USA Abstract Large blast events will fail building components, such as the façade and supporting structure. Facades present the...largest loading surface, are relatively weak, and will fail first and most violently when subjected to blast loads. The range of façade and structural

  17. 28 CFR 36.607 - Effect of certification.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes... the question of whether equipment in a building built according to the code satisfies the Act's... equivalency only with respect to those features or elements that are both covered by the certified code and...

  18. 76 FR 64924 - Updating State Residential Building Energy Efficiency Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-19

    ...) considers high-rise (greater than three stories) multifamily residential buildings and hotel, motel, and..., duplexes, townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such... pumps as compared to other electric heating technologies, this code change is expected to increase the...

  19. 7 CFR 1792.102 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... property will rank below the lien of another entity. Model Code—A building code developed for the adoption of local or state authorities or to be used as the basis of a local or state building code. NEHRP... Federally Assisted New Building Construction § 1792.102 Definitions. As used in this subpart, the following...

  20. 7 CFR 1792.102 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... property will rank below the lien of another entity. Model Code—A building code developed for the adoption of local or state authorities or to be used as the basis of a local or state building code. NEHRP... Federally Assisted New Building Construction § 1792.102 Definitions. As used in this subpart, the following...

  1. 7 CFR 1792.102 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... property will rank below the lien of another entity. Model Code—A building code developed for the adoption of local or state authorities or to be used as the basis of a local or state building code. NEHRP... Federally Assisted New Building Construction § 1792.102 Definitions. As used in this subpart, the following...

  2. 7 CFR 1792.102 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... property will rank below the lien of another entity. Model Code—A building code developed for the adoption of local or state authorities or to be used as the basis of a local or state building code. NEHRP... Federally Assisted New Building Construction § 1792.102 Definitions. As used in this subpart, the following...

  3. 7 CFR 1792.102 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... property will rank below the lien of another entity. Model Code—A building code developed for the adoption of local or state authorities or to be used as the basis of a local or state building code. NEHRP... Federally Assisted New Building Construction § 1792.102 Definitions. As used in this subpart, the following...

  4. An Efficient Audio Coding Scheme for Quantitative and Qualitative Large Scale Acoustic Monitoring Using the Sensor Grid Approach

    PubMed Central

    Gontier, Félix; Lagrange, Mathieu; Can, Arnaud; Lavandier, Catherine

    2017-01-01

    The spreading of urban areas and the growth of human population worldwide raise societal and environmental concerns. To better address these concerns, the monitoring of the acoustic environment in urban as well as rural or wilderness areas is an important matter. Building on the recent development of low cost hardware acoustic sensors, we propose in this paper to consider a sensor grid approach to tackle this issue. In this kind of approach, the crucial question is the nature of the data that are transmitted from the sensors to the processing and archival servers. To this end, we propose an efficient audio coding scheme based on third octave band spectral representation that allows: (1) the estimation of standard acoustic indicators; and (2) the recognition of acoustic events at state-of-the-art performance rate. The former is useful to provide quantitative information about the acoustic environment, while the latter is useful to gather qualitative information and build perceptually motivated indicators using for example the emergence of a given sound source. The coding scheme is also demonstrated to transmit spectrally encoded data that, reverted to the time domain using state-of-the-art techniques, are not intelligible, thus protecting the privacy of citizens. PMID:29186021

  5. New "Risk-Targeted" Seismic Maps Introduced into Building Codes

    USGS Publications Warehouse

    Luco, Nicholas; Garrett, B.; Hayes, J.

    2012-01-01

    Throughout most municipalities of the United States, structural engineers design new buildings using the U.S.-focused International Building Code (IBC). Updated editions of the IBC are published every 3 years. The latest edition (2012) contains new "risk-targeted maximum considered earthquake" (MCER) ground motion maps, which are enabling engineers to incorporate a more consistent and better defined level of seismic safety into their building designs.

  6. Adaptive antioxidant methionine accumulation in respiratory chain complexes explains the use of a deviant genetic code in mitochondria.

    PubMed

    Bender, Aline; Hajieva, Parvana; Moosmann, Bernd

    2008-10-28

    Humans and most other animals use 2 different genetic codes to translate their hereditary information: the standard code for nuclear-encoded proteins and a modern variant of this code in mitochondria. Despite the pivotal role of the genetic code for cell biology, the functional significance of the deviant mitochondrial code has remained enigmatic since its first description in 1979. Here, we show that profound and functionally beneficial alterations on the encoded protein level were causative for the AUA codon reassignment from isoleucine to methionine observed in most mitochondrial lineages. We demonstrate that this codon reassignment leads to a massive accumulation of the easily oxidized amino acid methionine in the highly oxidative inner mitochondrial membrane. This apparently paradoxical outcome can yet be smoothly settled if the antioxidant surface chemistry of methionine is taken into account, and we present direct experimental evidence that intramembrane accumulation of methionine exhibits antioxidant and cytoprotective properties in living cells. Our results unveil that methionine is an evolutionarily selected antioxidant building block of respiratory chain complexes. Collective protein alterations can thus constitute the selective advantage behind codon reassignments, which authenticates the "ambiguous decoding" hypothesis of genetic code evolution. Oxidative stress has shaped the mitochondrial genetic code.

  7. Pinoleville Pomo Nation Tribal Green Building Code

    EPA Pesticide Factsheets

    The Pinoleville Pomo Nation (PPN) worked with the U.S. Environmental Protection Agency (EPA) and the Development Center for Appropriate Technology (DCAT) to create this framework for tribal building codes.

  8. Deregulation of the Building Code and the Norwegian Approach to Regulation of Accessibility in the Built Environment.

    PubMed

    Lyngstad, Pål

    2016-01-01

    Deregulation is on the political agenda in the European countries. The Norwegian building code related to universal design and accessibility is challenged. To meet this, the Norwegian Building Authority have chosen to examine established truths and are basing their revised code on scientific research and field tests. But will this knowledge-based deregulation comply within the framework of the anti-discrimination act and, and if not: who suffers and to what extent?

  9. Potential Energy Cost Savings from Increased Commercial Energy Code Compliance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.

    2016-08-22

    An important question for commercial energy code compliance is: “How much energy cost savings can better compliance achieve?” This question is in sharp contrast to prior efforts that used a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. A field investigation method is being developed that goes beyond the binary approach to determine how much energy cost savings is not realized. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance for newly constructed officemore » buildings in climate zone 4C. Field data collected from actual buildings on specific conditions relative to code requirements was then applied to the simulation results to find the potential lost energy savings for a single building or for a sample of buildings. This new methodology was tested on nine office buildings in climate zone 4C. The amount of additional energy cost savings they could have achieved had they complied fully with the 2012 International Energy Conservation Code is determined. This paper will present the results of the test, lessons learned, describe follow-on research that is needed to verify that the methodology is both accurate and practical, and discuss the benefits that might accrue if the method were widely adopted.« less

  10. Building America Case Study: Evaluation of Passive Vents in New-Construction Multifamily Buildings, New York, New York

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as amore » potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.« less

  11. Earthquake scenario and probabilistic ground-shaking hazard maps for the Albuquerque-Belen-Santa Fe, New Mexico, corridor

    USGS Publications Warehouse

    Wong, I.; Olig, S.; Dober, M.; Silva, W.; Wright, D.; Thomas, P.; Gregor, N.; Sanford, A.; Lin, K.-W.; Love, D.

    2004-01-01

    These maps are not intended to be a substitute for site-specific studies for engineering design nor to replace standard maps commonly referenced in building codes. Rather, we hope that these maps will be used as a guide by government agencies; the engineering, urban planning, emergency preparedness, and response communities; and the general public as part of an overall program to reduce earthquake risk and losses in New Mexico.

  12. Building 65 Hydraulic Systems Handbook: Components, Systems, and Applications

    DTIC Science & Technology

    2016-04-01

    blocks. 1 REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704-0188 The public reporting burden for this collection of information is estimated...display a currently valid OMB control number. PLEASE DO NOT RETURN YOUR FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YY) 2. REPORT TYPE 3. DATES...Include Area Code) N/A Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39-18 i DISTRIBUTION STATEMENT A: Approved for public release

  13. An expanded genetic code in mammalian cells with a functional quadruplet codon.

    PubMed

    Niu, Wei; Schultz, Peter G; Guo, Jiantao

    2013-07-19

    We have utilized in vitro evolution to identify tRNA variants with significantly enhanced activity for the incorporation of unnatural amino acids into proteins in response to a quadruplet codon in both bacterial and mammalian cells. This approach will facilitate the creation of an optimized and standardized system for the genetic incorporation of unnatural amino acids using quadruplet codons, which will allow the biosynthesis of biopolymers that contain multiple unnatural building blocks.

  14. Functional assessment and performance evaluation for assistive robotic manipulators: Literature review

    PubMed Central

    Chung, Cheng-Shiu; Wang, Hongwu; Cooper, Rory A.

    2013-01-01

    Context The user interface development of assistive robotic manipulators can be traced back to the 1960s. Studies include kinematic designs, cost-efficiency, user experience involvements, and performance evaluation. This paper is to review studies conducted with clinical trials using activities of daily living (ADLs) tasks to evaluate performance categorized using the International Classification of Functioning, Disability, and Health (ICF) frameworks, in order to give the scope of current research and provide suggestions for future studies. Methods We conducted a literature search of assistive robotic manipulators from 1970 to 2012 in PubMed, Google Scholar, and University of Pittsburgh Library System – PITTCat. Results Twenty relevant studies were identified. Conclusion Studies were separated into two broad categories: user task preferences and user-interface performance measurements of commercialized and developing assistive robotic manipulators. The outcome measures and ICF codes associated with the performance evaluations are reported. Suggestions for the future studies include (1) standardized ADL tasks for the quantitative and qualitative evaluation of task efficiency and performance to build comparable measures between research groups, (2) studies relevant to the tasks from user priority lists and ICF codes, and (3) appropriate clinical functional assessment tests with consideration of constraints in assistive robotic manipulator user interfaces. In addition, these outcome measures will help physicians and therapists build standardized tools while prescribing and assessing assistive robotic manipulators. PMID:23820143

  15. Comment on "How can seismic hazard around the New Madrid seismic zone be similar to that in California?" by Arthur Frankel

    USGS Publications Warehouse

    Wang, Z.; Shi, B.; Kiefer, J.D.

    2005-01-01

    PSHA is the method used most to assess seismic hazards for input into various aspects of public and financial policy. For example, PSHA was used by the U.S. Geological Survey to develop the National Seismic Hazard Maps (Frankel et al., 1996, 2002). These maps are the basis for many national, state, and local seismic safety regulations and design standards, such as the NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures, the International Building Code, and the International Residential Code. Adoption and implementation of these regulations and design standards would have significant impacts on many communities in the New Madrid area, including Memphis, Tennessee and Paducah, Kentucky. Although "mitigating risks to society from earthquakes involves economic and policy issues" (Stein, 2004), seismic hazard assessment is the basis. Seismologists should provide the best information on seismic hazards and communicate them to users and policy makers. There is a lack of effort in communicating the uncertainties in seismic hazard assessment in the central U.S., however. Use of 10%, 5%, and 2% PE in 50 years causes confusion in communicating seismic hazard assessment. It would be easy to discuss and understand the design ground motions if the true meaning of the ground motion derived from PSHA were presented, i.e., the ground motion with the estimated uncertainty or the associated confidence level.

  16. Energy Efficiency Program Administrators and Building Energy Codes

    EPA Pesticide Factsheets

    Explore how energy efficiency program administrators have helped advance building energy codes at federal, state, and local levels—using technical, institutional, financial, and other resources—and discusses potential next steps.

  17. Alternative Fuels Data Center: Codes and Standards Resources

    Science.gov Websites

    codes and standards. Biodiesel Vehicle and Infrastructure Codes and Standards Chart Electric Vehicle and Infrastructure Codes and Standards Chart Ethanol Vehicle and Infrastructure Codes and Standards Chart Natural Gas Vehicle and Infrastructure Codes and Standards Chart Propane Vehicle and Infrastructure Codes and

  18. Designing Collaborative Developmental Standards by Refactoring of the Earth Science Models, Libraries, Workflows and Frameworks.

    NASA Astrophysics Data System (ADS)

    Mirvis, E.; Iredell, M.

    2015-12-01

    The operational (OPS) NOAA National Centers for Environmental Prediction (NCEP) suite, traditionally, consist of a large set of multi- scale HPC models, workflows, scripts, tools and utilities, which are very much depending on the variety of the additional components. Namely, this suite utilizes a unique collection of the in-house developed 20+ shared libraries (NCEPLIBS), certain versions of the 3-rd party libraries (like netcdf, HDF, ESMF, jasper, xml etc.), HPC workflow tool within dedicated (sometimes even vendors' customized) HPC system homogeneous environment. This domain and site specific, accompanied with NCEP's product- driven large scale real-time data operations complicates NCEP collaborative development tremendously by reducing chances to replicate this OPS environment anywhere else. The NOAA/NCEP's Environmental Modeling Center (EMC) missions to develop and improve numerical weather, climate, hydrological and ocean prediction through the partnership with the research community. Realizing said difficulties, lately, EMC has been taken an innovative approach to improve flexibility of the HPC environment by building the elements and a foundation for NCEP OPS functionally equivalent environment (FEE), which can be used to ease the external interface constructs as well. Aiming to reduce turnaround time of the community code enhancements via Research-to-Operations (R2O) cycle, EMC developed and deployed several project sub-set standards that already paved the road to NCEP OPS implementation standards. In this topic we will discuss the EMC FEE for O2R requirements and approaches in collaborative standardization, including NCEPLIBS FEE and models code version control paired with the models' derived customized HPC modules and FEE footprints. We will share NCEP/EMC experience and potential in the refactoring of EMC development processes, legacy codes and in securing model source code quality standards by using combination of the Eclipse IDE, integrated with the reverse engineering tools/APIs. We will also inform on collaborative efforts in the restructuring of the NOAA Environmental Modeling System (NEMS) - the multi- model and coupling framework, and transitioning FEE verification methodology.

  19. New features to the night sky radiance model illumina: Hyperspectral support, improved obstacles and cloud reflection

    NASA Astrophysics Data System (ADS)

    Aubé, M.; Simoneau, A.

    2018-05-01

    Illumina is one of the most physically detailed artificial night sky brightness model to date. It has been in continuous development since 2005 [1]. In 2016-17, many improvements were made to the Illumina code including an overhead cloud scheme, an improved blocking scheme for subgrid obstacles (trees and buildings), and most importantly, a full hyperspectral modeling approach. Code optimization resulted in significant reduction in execution time enabling users to run the model on standard personal computers for some applications. After describing the new schemes introduced in the model, we give some examples of applications for a peri-urban and a rural site both located inside the International Dark Sky reserve of Mont-Mégantic (QC, Canada).

  20. SHARD - a SeisComP3 module for Structural Health Monitoring

    NASA Astrophysics Data System (ADS)

    Weber, B.; Becker, J.; Ellguth, E.; Henneberger, R.; Herrnkind, S.; Roessler, D.

    2016-12-01

    Monitoring building and structure response to strong earthquake ground shaking or human-induced vibrations in real-time forms the backbone of modern structural health monitoring (SHM). The continuous data transmission, processing and analysis reduces drastically the time decision makers need to plan for appropriate response to possible damages of high-priority buildings and structures. SHARD is a web browser based module using the SeisComp3 framework to monitor the structural health of buildings and other structures by calculating standard engineering seismology parameters and checking their exceedance in real-time. Thresholds can be defined, e.g. compliant with national building codes (IBC2000, DIN4149 or EC8), for PGA/PGV/PGD, response spectra and drift ratios. In case thresholds are exceeded automatic or operator driven reports are generated and send to the decision makers. SHARD also determines waveform quality in terms of data delay and variance to report sensor status. SHARD is the perfect tool for civil protection to monitor simultaneously multiple city-wide critical infrastructure as hospitals, schools, governmental buildings and structures as bridges, dams and power substations.

  1. The international implications of national and local coordination on building energy codes: Case studies in six cities

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Evans, Meredydd; Yu, Sha; Staniszewski, Aaron

    Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy formore » All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.« less

  2. The international implications of national and local coordination on building energy codes: Case studies in six cities

    DOE PAGES

    Evans, Meredydd; Yu, Sha; Staniszewski, Aaron; ...

    2018-04-17

    Building energy efficiency is an important strategy for reducing greenhouse gas emissions globally. In fact, 55 countries have included building energy efficiency in their Nationally Determined Contributions (NDCs) under the Paris Agreement. This research uses building energy code implementation in six cities across different continents as case studies to assess what it may take for countries to implement the ambitions of their energy efficiency goals. Specifically, we look at the cases of Bogota, Colombia; Da Nang, Vietnam; Eskisehir, Turkey; Mexico City, Mexico; Rajkot, India; and Tshwane, South Africa, all of which are “deep dive” cities under the Sustainable Energy formore » All's Building Efficiency Accelerator. The research focuses on understanding the baseline with existing gaps in implementation and coordination. The methodology used a combination of surveys on code status and interviews with stakeholders at the local and national level, as well as review of published documents. We looked at code development, implementation, and evaluation. The cities are all working to improve implementation, however, the challenges they currently face include gaps in resources, capacity, tools, and institutions to check for compliance. Better coordination between national and local governments could help improve implementation, but that coordination is not yet well established. For example, all six of the cities reported that there was little to no involvement of local stakeholders in development of the national code; only one city reported that it had access to national funding to support code implementation. More robust coordination could better link cities with capacity building and funding for compliance, and ensure that the code reflects local priorities. By understanding gaps in implementation, it can also help in designing more targeted interventions to scale up energy savings.« less

  3. Building an ontology of pulmonary diseases with natural language processing tools using textual corpora.

    PubMed

    Baneyx, Audrey; Charlet, Jean; Jaulent, Marie-Christine

    2007-01-01

    Pathologies and acts are classified in thesauri to help physicians to code their activity. In practice, the use of thesauri is not sufficient to reduce variability in coding and thesauri are not suitable for computer processing. We think the automation of the coding task requires a conceptual modeling of medical items: an ontology. Our task is to help lung specialists code acts and diagnoses with software that represents medical knowledge of this concerned specialty by an ontology. The objective of the reported work was to build an ontology of pulmonary diseases dedicated to the coding process. To carry out this objective, we develop a precise methodological process for the knowledge engineer in order to build various types of medical ontologies. This process is based on the need to express precisely in natural language the meaning of each concept using differential semantics principles. A differential ontology is a hierarchy of concepts and relationships organized according to their similarities and differences. Our main research hypothesis is to apply natural language processing tools to corpora to develop the resources needed to build the ontology. We consider two corpora, one composed of patient discharge summaries and the other being a teaching book. We propose to combine two approaches to enrich the ontology building: (i) a method which consists of building terminological resources through distributional analysis and (ii) a method based on the observation of corpus sequences in order to reveal semantic relationships. Our ontology currently includes 1550 concepts and the software implementing the coding process is still under development. Results show that the proposed approach is operational and indicates that the combination of these methods and the comparison of the resulting terminological structures give interesting clues to a knowledge engineer for the building of an ontology.

  4. Extremely Fast Numerical Integration of Ocean Surface Wave Dynamics: Building Blocks for a Higher Order Method

    DTIC Science & Technology

    2006-09-30

    equation known as the Kadomtsev - Petviashvili (KP) equation ): (ηt + coηx +αηηx + βη )x +γηyy = 0 (4) where γ = co / 2 . The KdV equation ...using the spectral formulation of the Kadomtsev - Petviashvili equation , a standard equation for nonlinear, shallow water wave dynamics that is a... Petviashvili and nonlinear Schroedinger equations and higher order corrections have been developed as prerequisites to coding the Boussinesq and Euler

  5. Sequential neural text compression.

    PubMed

    Schmidhuber, J; Heil, S

    1996-01-01

    The purpose of this paper is to show that neural networks may be promising tools for data compression without loss of information. We combine predictive neural nets and statistical coding techniques to compress text files. We apply our methods to certain short newspaper articles and obtain compression ratios exceeding those of the widely used Lempel-Ziv algorithms (which build the basis of the UNIX functions "compress" and "gzip"). The main disadvantage of our methods is that they are about three orders of magnitude slower than standard methods.

  6. Profile of the wood furniture and fixtures industry. EPA Office of Compliance sector notebook project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1995-09-01

    The furniture and fixtures industry encompasses companies that manufacture household, office, store, public building, and restaurant furniture and fixtures. The second section provides background information on the size, geographic distribution, employment, production, sales, and economic condition of the Wood Furniture and Fixtures industry. The type of facilities described within the document are also described in terms of their Standard Industrial Classification (SIC) codes. Additionally, this section contains a list of the largest companies in terms of sales.

  7. Tornado risks and design windspeeds for the Oak Ridge Plant Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1975-08-01

    The effects of tornadoes and other extreme winds should be considered in establishing design criteria for structures to resist wind loads. Design standards that are incorporated in building codes do not normally include the effects of tornadoes in their wind load criteria. Some tornado risk models ignore the presence of nontornadic extreme winds. The purpose of this study is to determine the probability of tornadic and straight winds exceeding a threshold value in the geographical region surrounding the Oak Ridge, Tennessee plant site.

  8. Data Collection Handbook to Support Modeling Impacts of Radioactive Material in Soil and Building Structures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Charley; Kamboj, Sunita; Wang, Cheng

    2015-09-01

    This handbook is an update of the 1993 version of the Data Collection Handbook and the Radionuclide Transfer Factors Report to support modeling the impact of radioactive material in soil. Many new parameters have been added to the RESRAD Family of Codes, and new measurement methodologies are available. A detailed review of available parameter databases was conducted in preparation of this new handbook. This handbook is a companion document to the user manuals when using the RESRAD (onsite) and RESRAD-OFFSITE code. It can also be used for RESRAD-BUILD code because some of the building-related parameters are included in this handbook.more » The RESRAD (onsite) has been developed for implementing U.S. Department of Energy Residual Radioactive Material Guidelines. Hydrogeological, meteorological, geochemical, geometrical (size, area, depth), crops and livestock, human intake, source characteristic, and building characteristic parameters are used in the RESRAD (onsite) code. The RESRAD-OFFSITE code is an extension of the RESRAD (onsite) code and can also model the transport of radionuclides to locations outside the footprint of the primary contamination. This handbook discusses parameter definitions, typical ranges, variations, and measurement methodologies. It also provides references for sources of additional information. Although this handbook was developed primarily to support the application of RESRAD Family of Codes, the discussions and values are valid for use of other pathway analysis models and codes.« less

  9. Green Building Tools for Tribes

    EPA Pesticide Factsheets

    Tribal green building tools and funding information to support tribal building code adoption, healthy building, siting, energy efficiency, renewable energy, water conservation, green building materials, recycling and adaptation and resilience.

  10. Designed to deter: Barriers to facilities at secondary schools in Ghana

    PubMed Central

    Owusu-Ansah, Frances E.; Alorwu, Divine

    2012-01-01

    Background There are varied and complex problems associated with the admission of students with disabilities into secondary (senior high) schools all over the world. This situation is further complicated by difficulties encountered in the built environment of these institutions and, in this, Ghana is no exception. Objectives This exploratory study investigated the level of accessibility of the built environment in secondary schools in eight out of the ten regions of Ghana, in order to determine whether they conform to guidelines provided in international building standards and also assess the extent to which they have been designed and constructed to meet the provisions of the Persons with Disability Act 2006, which allows for equal access to public buildings in Ghana. Method In total, 705 building elements in 264 facilities were surveyed using international standards, building codes, regulations and guidelines. These facilities included car parks, classrooms, dormitories, assembly halls, telephone booths and administration blocks. Results Our findings revealed that most of the building elements were barring and not disability-friendly. Just to name a few: there were obstructions on access routes to and around buildings, absence of designated car parks, unfriendly vertical and horizontal means of circulation in buildings and lack of accessible sanitary accommodations. In addition, the general lighting and signage were poor. As a result, very few students with disabilities are admitted and retained in these schools. Conclusion Mainstreaming of people with disabilities into the Ghanaian educational system remains impossible unless urgent action is taken to alter the facilities at secondary schools. Based on this research outcome, recommendations have been made to the Ghanaian government and the Ghana Education Service, as well as non-governmental organisations and relevant professional bodies for the amelioration of the present situation in our secondary schools. PMID:28729972

  11. Capturing Energy-Saving Opportunities: Improving Building Efficiency in Rajasthan through Energy Code Implementation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tan, Qing; Yu, Sha; Evans, Meredydd

    2016-05-01

    India adopted the Energy Conservation Building Code (ECBC) in 2007. Rajasthan is the first state to make ECBC mandatory at the state level. In collaboration with Malaviya National Institute of Technology (MNIT) Jaipur, Pacific Northwest National Laboratory (PNNL) has been working with Rajasthan to facilitate the implementation of ECBC. This report summarizes milestones made in Rajasthan and PNNL's contribution in institutional set-ups, capacity building, compliance enforcement and pilot building construction.

  12. 25 CFR 36.104 - What are the requirements for heating, ventilation, cooling and lighting at dormitories?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... building codes in the Bureau of Indian Affairs “School Facilities Design Handbook,” dated March 30, 2007... any proposal to change which building codes are included in the Bureau of Indian Affairs “School... inspect the Handbook at the Department of the Interior Library, Main Interior Building, 1849 C Street NW...

  13. 25 CFR 36.104 - What are the requirements for heating, ventilation, cooling and lighting at dormitories?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... building codes in the Bureau of Indian Affairs “School Facilities Design Handbook,” dated March 30, 2007... any proposal to change which building codes are included in the Bureau of Indian Affairs “School... inspect the Handbook at the Department of the Interior Library, Main Interior Building, 1849 C Street NW...

  14. Energy and Environment Guide to Action - Chapter 4.3: Building Codes for Energy Efficiency

    EPA Pesticide Factsheets

    Provides guidance and recommendations for establishing, implementing, and evaluating state building codes for energy efficiency, which improve energy efficiency in new construction and major renovations. State success stories are included for reference.

  15. Application of the Life Safety Code to a Historic Test Stand

    NASA Technical Reports Server (NTRS)

    Askins, Bruce; Lemke, Paul R.; Lewis, William L.; Covell, Carol C.

    2011-01-01

    NASA has conducted a study to assess alternatives to refurbishing existing launch vehicle modal test facilities as opposed to developing new test facilities to meet the demands of a very fiscally constrained test and evaluation environment. The results of this study showed that Marshall Space Flight Center (MSFC) Test Stand (TS) 4550 could be made compliant, within reasonable cost and schedule impacts, if safety processes and operational limitations were put in place to meet the safety codes and concerns of the Fire Marshall. Trades were performed with key selection criteria to ensure that appropriate levels of occupant safety are incorporated into test facility design modifications. In preparation for the ground vibration tests that were to be performed on the Ares I launch vehicle, the Ares Flight and Integrated Test Office (FITO) organization evaluated the available test facility options, which included the existing mothballed structural dynamic TS4550 used by Apollo and Shuttle, alternative ground vibration test facilities at other locations, and construction of a new dynamic test stand. After an exhaustive assessment of the alternatives, the results favored modifying the TS4550 because it was the lowest cost option and presented the least schedule risk to the NASA Constellation Program for Ares Integrated Vehicle Ground Vibration Test (IVGVT). As the renovation design plans and drawings were being developed for TS4550, a safety concern was discovered the original design for the construction of the test stand, originally built for the Apollo Program and renovated for the Shuttle Program, was completed before NASA s adoption of the currently imposed safety and building codes per National Fire Protection Association Life Safety Code [NFPA 101] and International Building Codes. The initial FITO assessment of the design changes, required to make TS4550 compliant with current safety and building standards, identified a significant cost increase and schedule impact. An effort was launched to thoroughly evaluate the applicable life safety requirements, examine the context in which they were derived, and determine a means by which the TS4550 modifications could be made within budget and on schedule, while still providing the occupants with appropriate levels of safety.

  16. Automatic HDL firmware generation for FPGA-based reconfigurable measurement and control systems with mezzanines in FMC standard

    NASA Astrophysics Data System (ADS)

    Wojenski, Andrzej; Kasprowicz, Grzegorz; Pozniak, Krzysztof T.; Romaniuk, Ryszard

    2013-10-01

    The paper describes a concept of automatic firmware generation for reconfigurable measurement systems, which uses FPGA devices and measurement cards in FMC standard. Following sections are described in details: automatic HDL code generation for FPGA devices, automatic communication interfaces implementation, HDL drivers for measurement cards, automatic serial connection between multiple measurement backplane boards, automatic build of memory map (address space), automatic generated firmware management. Presented solutions are required in many advanced measurement systems, like Beam Position Monitors or GEM detectors. This work is a part of a wider project for automatic firmware generation and management of reconfigurable systems. Solutions presented in this paper are based on previous publication in SPIE.

  17. Peripheral infrastructure vectors and an extended set of plant parts for the Modular Cloning system

    PubMed Central

    Kretschmer, Carola; Gruetzner, Ramona; Löfke, Christian; Dagdas, Yasin; Bürstenbinder, Katharina; Marillonnet, Sylvestre

    2018-01-01

    Standardized DNA assembly strategies facilitate the generation of multigene constructs from collections of building blocks in plant synthetic biology. A common syntax for hierarchical DNA assembly following the Golden Gate principle employing Type IIs restriction endonucleases was recently developed, and underlies the Modular Cloning and GoldenBraid systems. In these systems, transcriptional units and/or multigene constructs are assembled from libraries of standardized building blocks, also referred to as phytobricks, in several hierarchical levels and by iterative Golden Gate reactions. Here, a toolkit containing further modules for the novel DNA assembly standards was developed. Intended for use with Modular Cloning, most modules are also compatible with GoldenBraid. Firstly, a collection of approximately 80 additional phytobricks is provided, comprising e.g. modules for inducible expression systems, promoters or epitope tags. Furthermore, DNA modules were developed for connecting Modular Cloning and Gateway cloning, either for toggling between systems or for standardized Gateway destination vector assembly. Finally, first instances of a “peripheral infrastructure” around Modular Cloning are presented: While available toolkits are designed for the assembly of plant transformation constructs, vectors were created to also use coding sequence-containing phytobricks directly in yeast two hybrid interaction or bacterial infection assays. The presented material will further enhance versatility of hierarchical DNA assembly strategies. PMID:29847550

  18. Building a Better Trojan Horse: Emerging Army Roles in Joint Urban Operations

    DTIC Science & Technology

    2001-01-01

    Building a Better Trojan Horse : Emerging Army Roles in Joint Urban Operations A Monograph by MAJ Christopher H. Beckert Infantry, U.S. Army School...xx-xx-2000 to xx-xx-2000 5a. CONTRACT NUMBER 5b. GRANT NUMBER 4. TITLE AND SUBTITLE Building a Better Trojan Horse : Emerging Army Roles in Joint...TELEPHONE NUMBER International Area Code Area Code Telephone Number 703 767-9007 DSN 427-9007 2 Abstract BUILDING A BETTER TROJAN HORSE : EMERGING ARMY

  19. Effects of recent energy system changes on CO2 projections for the United States.

    PubMed

    Lenox, Carol S; Loughlin, Daniel H

    2017-09-21

    Recent projections of future United States carbon dioxide (CO 2 ) emissions are considerably lower than projections made just a decade ago. A myriad of factors have contributed to lower forecasts, including reductions in end-use energy service demands, improvements in energy efficiency, and technological innovations. Policies that have encouraged these changes include renewable portfolio standards, corporate vehicle efficiency standards, smart growth initiatives, revisions to building codes, and air and climate regulations. Understanding the effects of these and other factors can be advantageous as society evaluates opportunities for achieving additional CO 2 reductions. Energy system models provide a means to develop such insights. In this analysis, the MARKet ALlocation (MARKAL) model was applied to estimate the relative effects of various energy system changes that have happened since the year 2005 on CO 2 projections for the year 2025. The results indicate that transformations in the transportation and buildings sectors have played major roles in lowering projections. Particularly influential changes include improved vehicle efficiencies, reductions in projected travel demand, reductions in miscellaneous commercial electricity loads, and higher efficiency lighting. Electric sector changes have also contributed significantly to the lowered forecasts, driven by demand reductions, renewable portfolio standards, and air quality regulations.

  20. Assessing Potential Energy Cost Savings from Increased Energy Code Compliance in Commercial Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenberg, Michael I.; Hart, Philip R.; Athalye, Rahul A.

    The US Department of Energy’s most recent commercial energy code compliance evaluation efforts focused on determining a percent compliance rating for states to help them meet requirements under the American Recovery and Reinvestment Act (ARRA) of 2009. That approach included a checklist of code requirements, each of which was graded pass or fail. Percent compliance for any given building was simply the percent of individual requirements that passed. With its binary approach to compliance determination, the previous methodology failed to answer some important questions. In particular, how much energy cost could be saved by better compliance with the commercial energymore » code and what are the relative priorities of code requirements from an energy cost savings perspective? This paper explores an analytical approach and pilot study using a single building type and climate zone to answer those questions.« less

  1. Harmonizing clinical terminologies: driving interoperability in healthcare.

    PubMed

    Hamm, Russell A; Knoop, Sarah E; Schwarz, Peter; Block, Aaron D; Davis, Warren L

    2007-01-01

    Internationally, there are countless initiatives to build National Healthcare Information Networks (NHIN) that electronically interconnect healthcare organizations by enhancing and integrating current information technology (IT) capabilities. The realization of such NHINs will enable the simple and immediate exchange of appropriate and vital clinical data among participating organizations. In order for institutions to accurately and automatically exchange information, the electronic clinical documents must make use of established clinical codes, such as those of SNOMED-CT, LOINC and ICD-9 CM. However, there does not exist one universally accepted coding scheme that encapsulates all pertinent clinical information for the purposes of patient care, clinical research and population heatlh reporting. In this paper, we propose a combination of methods and standards that target the harmonization of clinical terminologies and encourage sustainable, interoperable infrastructure for healthcare.

  2. Alternative Fuels Data Center: Biodiesel Codes, Standards, and Safety

    Science.gov Websites

    Codes, Standards, and Safety to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Codes, Standards, and Safety on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Codes , Standards, and Safety on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Codes, Standards, and

  3. The case of the high-risk safety product.

    PubMed

    Chew, W B; Blodgett, T B; Wallin, W R; Meyers, G C; Holden, B; Johnson, E W; Smith, N C; Ducker, W

    1992-01-01

    After several days of meetings, J.F. Winchester, president of MDC Industries, felt no closer to a decision. MDC, a manufacturer of wall and ceiling panels, was considering whether to exercise an option to buy a new and safer wallboard technology. The product was being touted as revolutionary, but, Winchester wondered, could MDC afford to carry the flag? According to its inventor, Robert Goerner, Smoke-Safe would be a vast improvement over standard safety-rated wallboard. With almost the same flame-retardant properties, Smoke-Safe had the advantage of giving off almost no fumes or smoke in fire tests. And, Winchester knew, most fire-related deaths are from smoke, not flames. Indeed, the numbers were grimly persuasive: 82% of fire-related injuries involving standard panels were caused by smoke inhalation. What's more, Smoke-Safe would cost about the same to manufacture as MDC's current wallboard. But MDC had several other good options for spending the $5 million Goerner was asking; building plastics was only one of its profit centers. And the prospect of launching a campaign to change building codes in order to market Smoke-Safe, which could spark a fight with competitors, was daunting. Since its current wallboard gave MDC only 18% of the wallboard market, many industry insiders speculated whether MDC had the market clout to influence major cities to revise their codes. Six experts in marketing, law, and ethics advise MDC Industries on how it can balance ethical and business imperatives in making its decision.

  4. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Idaho

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Idaho. Moving to the 2015 IECC from the 2015 Idaho State Code base code is cost-effective for residential buildings in all climate zones in Idaho.

  5. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Montana

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Montana. Moving to the 2015 IECC from the 2014 Montana State Code base code is cost-effective for residential buildings in all climate zones in Montana.

  6. 75 FR 20833 - Building Energy Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-21

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy [Docket No. EERE-2010-BT-BC-0012] Building Energy Codes AGENCY: Office of Energy Efficiency and Renewable Energy, Department of Energy. ACTION: Request for Information. SUMMARY: The U.S. Department of Energy (DOE) is soliciting...

  7. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Iowa

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in Iowa. Moving to the 2015 IECC from the 2014 Iowa State Code base code is cost-effective for residential buildings in all climate zones in Iowa.

  8. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for Utah

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    The 2015 IECC provides cost-effective savings for residential buildings in Utah. Moving to the 2015 IECC from the 2012 Utah State Code base code is cost-effective for residential buildings in all climate zones in Utah.

  9. Energy Cost Impact of Non-Residential Energy Code Requirements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Jian; Hart, Philip R.; Rosenberg, Michael I.

    2016-08-22

    The 2012 International Energy Conservation Code contains 396 separate requirements applicable to non-residential buildings; however, there is no systematic analysis of the energy cost impact of each requirement. Consequently, limited code department budgets for plan review, inspection, and training cannot be focused on the most impactful items. An inventory and ranking of code requirements based on their potential energy cost impact is under development. The initial phase focuses on office buildings with simple HVAC systems in climate zone 4C. Prototype building simulations were used to estimate the energy cost impact of varying levels of non-compliance. A preliminary estimate of themore » probability of occurrence of each level of non-compliance was combined with the estimated lost savings for each level to rank the requirements according to expected savings impact. The methodology to develop and refine further energy cost impacts, specific to building type, system type, and climate location is demonstrated. As results are developed, an innovative alternative method for compliance verification can focus efforts so only the most impactful requirements from an energy cost perspective are verified for every building and a subset of the less impactful requirements are verified on a random basis across a building population. The results can be further applied in prioritizing training material development and specific areas of building official training.« less

  10. Monitor Network Traffic with Packet Capture (pcap) on an Android Device

    DTIC Science & Technology

    2015-09-01

    administrative privileges . Under the current design Android development requirement, an Android Graphical User Interface (GUI) application cannot directly...build an Android application to monitor network traffic using open source packet capture (pcap) libraries. 15. SUBJECT TERMS ELIDe, Android , pcap 16...Building Application with Native Codes 5 8.1 Calling Native Codes Using JNI 5 8.2 Calling Native Codes from an Android Application 8 9. Retrieve Live

  11. Evaluation of Passive Vents in New Construction Multifamily Buildings

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxwell, Sean; Berger, David; Zuluaga, Marc

    Exhaust ventilation and corresponding outdoor air strategies are being implemented in high-performance new construction multifamily buildings to meet program or code requirements for improved indoor air quality, but a lack of clear design guidance is resulting in poor performance of these systems despite the best intentions of the programs or standards. CARB's 2014 'Evaluation of Ventilation Strategies in New Construction Multifamily Buildings' consistently demonstrated that commonly used outdoor air strategies are not performing as expected. Of the four strategies evaluated in 2014, the exhaust ventilation system that relied on outdoor air from a pressurized corridor was ruled out as amore » potential best practice due to its conflict with meeting requirements within most fire codes. Outdoor air that is ducted directly to the apartments was a strategy determined to have the highest likelihood of success, but with higher first costs and operating costs. Outdoor air through space conditioning systems was also determined to have good performance potential, with proper design and execution. The fourth strategy, passive systems, was identified as the least expensive option for providing outdoor air directly to apartments, with respect to both first costs and operating costs. However, little is known about how they actually perform in real-world conditions or how to implement them effectively. Based on the lack of data available on the performance of these low-cost systems and their frequent use in the high-performance building programs that require a provision for outdoor air, this research project sought to further evaluate the performance of passive vents.« less

  12. Educational Labeling System for Atmospheres (ELSA): Python Tool Development for Archiving Under the PDS4 Standard

    NASA Astrophysics Data System (ADS)

    Neakrase, Lynn; Hornung, Danae; Sweebe, Kathrine; Huber, Lyle; Chanover, Nancy J.; Stevenson, Zena; Berdis, Jodi; Johnson, Joni J.; Beebe, Reta F.

    2017-10-01

    The Research and Analysis programs within NASA’s Planetary Science Division now require archiving of resultant data with the Planetary Data System (PDS) or an equivalent archive. The PDS Atmospheres Node is developing an online environment for assisting data providers with this task. The Educational Labeling System for Atmospheres (ELSA) is being designed with Django/Python coding to provide an easier environment for facilitating not only communication with the PDS node, but also streamlining the process of learning, developing, submitting, and reviewing archive bundles under the new PDS4 archiving standard. Under the PDS4 standard, data are archived in bundles, collections, and basic products that form an organizational hierarchy of interconnected labels that describe the data and relationships between the data and its documentation. PDS4 labels are implemented using Extensible Markup Language (XML), which is an international standard for managing metadata. Potential data providers entering the ELSA environment can learn more about PDS4, plan and develop label templates, and build their archive bundles. ELSA provides an interface to tailor label templates aiding in the creation of required internal Logical Identifiers (URN - Uniform Resource Names) and Context References (missions, instruments, targets, facilities, etc.). The underlying structure of ELSA uses Django/Python code that make maintaining and updating the interface easy to do for our undergraduate/graduate students. The ELSA environment will soon provide an interface for using the tailored templates in a pipeline to produce entire collections of labeled products, essentially building the user’s archive bundle. Once the pieces of the archive bundle are assembled, ELSA provides options for queuing the completed bundle for peer review. The peer review process has also been streamlined for online access and tracking to help make the archiving process with PDS as transparent as possible. We discuss the current status of ELSA and provide examples of its implementation.

  13. Mass Housing Using GFRG Panels: A Sustainable, Rapid and Affordable Solution

    NASA Astrophysics Data System (ADS)

    Cherian, Philip; Paul, Shinto; Krishna, S. R. Gouri; Menon, Devdas; Meher Prasad, A.

    2017-06-01

    This work gives an overview of research and development carried out at IIT Madras, using glass fibre reinforced gypsum (GFRG) panels, to provide an innovative solution for rapid and affordable mass housing. The GFRG panels (124 mm thick), made from recycled industrial waste gypsum (from the fertilizer industry), are prefabricated in 3 m × 12 m sizes with cellular cavities inside, which can be filled with reinforced concrete wherever required and can be used as walls as well as floor slabs. The tests carried out (over the past 12 years) establish the performance of GFRG building systems to resist gravity and lateral loads as a load-bearing system (without beams and columns) in multi-storeyed buildings up to 8-10 storeys, with adequate strength, serviceability, durability and ductility. A two-storeyed four-apartment demonstration building has also been successfully constructed in the IIT Madras campus and presently a mass housing scheme (40 apartment units) using this technology is being demonstrated at Nellore. A structural design code has also been approved by the Bureau of Indian Standards, based on the extensive studies carried out on GFRG building systems.

  14. Evaluation of Safety, Quality and Productivity in Construction

    NASA Astrophysics Data System (ADS)

    Usmen, M. A.; Vilnitis, M.

    2015-11-01

    This paper examines the success indicators of construction projects, safety, quality and productivity, in terms of their implications and impacts during and after construction. First safety is considered during construction with a focus on hazard identification and the prevention of occupational accidents and injuries on worksites. The legislation mandating safety programs, training and compliance with safety standards is presented and discussed. Consideration of safety at the design stage is emphasized. Building safety and the roles of building codes in prevention of structural failures are also covered in the paper together with factors affecting building failures and methods for their prevention. Quality is introduced in the paper from the perspective of modern total quality management. Concepts of quality management, quality control, quality assurance and Six Sigma and how they relate to building quality and structural integrity are discussed with examples. Finally, productivity concepts are presented with emphasis on effective project management to minimize loss of productivity, complimented by lean construction and lean Six Sigma principles. The paper concludes by synthesizing the relationships between safety, quality and productivity.

  15. Tribal Green Building Toolkit

    EPA Pesticide Factsheets

    This Tribal Green Building Toolkit (Toolkit) is designed to help tribal officials, community members, planners, developers, and architects develop and adopt building codes to support green building practices. Anyone can use this toolkit!

  16. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for New Hampshire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in New Hampshire. Moving to the 2015 IECC from the 2010 New Hampshire State Code base code is cost-effective for residential buildings in all climate zones in New Hampshire.

  17. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for North Carolina

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in North Carolina. Moving to the 2015 IECC from the 2012 North Carolina State Code base code is cost-effective for residential buildings in all climate zones in North Carolina.

  18. Awareness and implementation of the regional animal welfare strategy for the Americas: a questionnaire.

    PubMed

    Glass, E; Kahn, S; Arroyo Kuribreha, M

    2015-12-01

    The World Organisation for Animal Health (OIE) is the global standard-setting organisation for animal health and these standards are references for the World Trade Organization legal framework. In 2002, noting the relationship between animal health and welfare, the OIE accepted the mandate to develop animal welfare standards. These standards were subsequently adopted by Member Countries and have been included in the TerrestrialAnimal Health Code and the Aquatic Animal Health Code. The implementation of the OIE standards by Member Countries is continually promoted. National OIE Delegates are encouraged to nominate National Focal Points for key topics, including animal welfare. In 2012, the OIE Regional Commission of the Americas adopted a Regional Animal Welfare Strategy (Regional Strategy) to promote a coordinated approach to the implementation of the OIE animal welfare standards by the 29 Member Countries in the region. In February 2015, the OIE Regional Representation for the Americas distributed a questionnaire to determine the level of awareness and implementation of the Regional Strategy. This paper presents the results of the questionnaire. With a few exceptions, veterinary officials and stakeholders are only just becoming aware of the strategy and implementation is at an early stage. To promote the implementation of the Regional Strategy, it will be.necessary to continue building the capacity of the national Veterinary Services, strengthening public-private partnerships, modernising legislation and promoting veterinary involvement in animal welfare. Through the implementation of the Regional Strategy, the OIE will provide support to countries in establishing animal welfare standards, in line with government priorities and consumer concerns.

  19. Xenobiology: State-of-the-Art, Ethics, and Philosophy of New-to-Nature Organisms.

    PubMed

    Schmidt, Markus; Pei, Lei; Budisa, Nediljko

    The basic chemical constitution of all living organisms in the context of carbon-based chemistry consists of a limited number of small molecules and polymers. Until the twenty-first century, biology was mainly an analytical science and has now reached a point where it merges with engineering science, paving the way for synthetic biology. One of the objectives of synthetic biology is to try to change the chemical compositions of living cells, that is, to create an artificial biological diversity, which in turn fosters a new sub-field of synthetic biology, xenobiology. In particular, the genetic code in living systems is based on highly standardized chemistry composed of the same "letters" or nucleotides as informational polymers (DNA, RNA) and the 20 amino acids which serve as basic building blocks for proteins. The universality of the genetic code enables not only vertical gene transfer within the same species but also horizontal gene transfer across biological taxa, which require a high degree of standardization and interconnectivity. Although some minor alterations of the standard genetic code are found in nature (e.g., proteins containing non-conical amino acids exist in nature, and some organisms use alternated coding systems), all structurally deep chemistry changes within living systems are generally lethal, making the creation of artificial biological system an extremely difficult challenge.In this context, one of the great challenges for bioscience is the development of a strategy for expanding the standard basic chemical repertoire of living cells. Attempts to alter the meaning of the genetic information stored in DNA as an informational polymer by changing the chemistry of the polymer (i.e., xeno-nucleic acids) or by changes in the genetic code have already yielded successful results. In the future this should enable the partial or full redirection of the biological information flow to generate "new" version(s) of the genetic code derived from the "old" biological world.In addition to the scientific challenges, the attempt to increase biochemical diversity also raises important ethical and philosophical issues. Although promotors of this branch of synthetic biology highlight the many potential applications to come (e.g., novel tools for diagnostics and fighting infection diseases), such developments could also bring risks affecting social, political, and other structures of nearly all societies.

  20. Gnuastro: GNU Astronomy Utilities

    NASA Astrophysics Data System (ADS)

    Akhlaghi, Mohammad

    2018-01-01

    Gnuastro (GNU Astronomy Utilities) manipulates and analyzes astronomical data. It is an official GNU package of a large collection of programs and C/C++ library functions. Command-line programs perform arithmetic operations on images, convert FITS images to common types like JPG or PDF, convolve an image with a given kernel or matching of kernels, perform cosmological calculations, crop parts of large images (possibly in multiple files), manipulate FITS extensions and keywords, and perform statistical operations. In addition, it contains programs to make catalogs from detection maps, add noise, make mock profiles with a variety of radial functions using monte-carlo integration for their centers, match catalogs, and detect objects in an image among many other operations. The command-line programs share the same basic command-line user interface for the comfort of both the users and developers. Gnuastro is written to comply fully with the GNU coding standards and integrates well with all Unix-like operating systems. This enables astronomers to expect a fully familiar experience in the source code, building, installing and command-line user interaction that they have seen in all the other GNU software that they use. Gnuastro's extensive library is included for users who want to build their own unique programs.

  1. Establishment and advances in the online Serbian food and recipe data base harmonized with EuroFIR™ standards.

    PubMed

    Gurinović, Mirjana; Milešević, Jelena; Kadvan, Agnes; Djekić-Ivanković, Marija; Debeljak-Martačić, Jasmina; Takić, Marija; Nikolić, Marina; Ranković, Slavica; Finglas, Paul; Glibetić, Maria

    2016-02-15

    Within the European Food Information Resource Network of Excellence (EuroFIR NoE; FP6) and EuroFIR Nexus (FP7) project paucity in food composition databases (FCDB) in the Central Eastern Europe/Balkan (CEE/B) region was identified. As a member of EuroFIR NoE, the Centre of Research Excellence in Nutrition and Metabolism, Serbia initiated creation of the 1st online Serbian FCDB employing EuroFIR quality framework and CEN Food Data Standard requirements, supporting capacity development and designing the web-based Food Composition Data Management (FCDM) software for FCDB building. The 1st online version of Serbian FCDB was launched in 2007, and then extended with food composition data from other Balkan countries (Balkan Food Platform-Regional FCDB). All foods are indexed using LanguaL Thesaurus and coded with EFSA FoodEx2 coding system. To date, upgraded Serbian FCDB with 1046 foods and 129 traditional/common Serbian composite dishes is a prerequisite for nutritional research in Serbia, CEE/B region and wider Europe. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Demonstration of Energy Savings in Commercial Buildings for Tiered Trim and Respond Method in Resetting Static Pressure for VAV Systems

    DTIC Science & Technology

    2017-03-01

    Systems March 2017 This document has been cleared for public release; Distribution Statement A REPORT DOCUMENTATION PAGE Form Approved OMB No. 0704... FORM TO THE ABOVE ADDRESS. 1. REPORT DATE (DD-MM-YYYY) 28-02-2017 2. REPORT TYPE Cost and Performance Report 3. DATES COVERED (From - To) September...ABSTRACT c. THIS PAGE 71 19b. TELEPHONE NUMBER (include area code) (515)965-7342 Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std. Z39.18 Page

  3. The receptive field is dead. Long live the receptive field?

    PubMed Central

    Fairhall, Adrienne

    2014-01-01

    Advances in experimental techniques, including behavioral paradigms using rich stimuli under closed loop conditions and the interfacing of neural systems with external inputs and outputs, reveal complex dynamics in the neural code and require a revisiting of standard concepts of representation. High-throughput recording and imaging methods along with the ability to observe and control neuronal subpopulations allow increasingly detailed access to the neural circuitry that subserves these representations and the computations they support. How do we harness theory to build biologically grounded models of complex neural function? PMID:24618227

  4. Quantifying the benefits of a building retrofit using an integrated system approach: A case study

    DOE PAGES

    Regnier, Cynthia; Sun, Kaiyu; Hong, Tianzhen; ...

    2017-11-11

    Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimummore » code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.« less

  5. Quantifying the benefits of a building retrofit using an integrated system approach: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Regnier, Cynthia; Sun, Kaiyu; Hong, Tianzhen

    Building retrofits provide a large opportunity to significantly reduce energy consumption in the buildings sector. Traditional building retrofits focus on equipment upgrades, often at the end of equipment life or failure, and result in replacement with marginally improved similar technology and limited energy savings. The Integrated System (IS) retrofit approach enables much greater energy savings by leveraging interactive effects between end use systems, enabling downsized or lower energy technologies. This work presents a case study in Hawaii quantifying the benefits of an IS retrofit approach compared to two traditional retrofit approaches: a Standard Practice of upgrading equipment to meet minimummore » code requirements, and an Improved Practice of upgrading equipment to a higher efficiency. The IS approach showed an energy savings of 84% over existing building energy use, much higher than the traditional approaches of 13% and 33%. The IS retrofit also demonstrated the greatest energy cost savings potential. While the degree of savings realized from the IS approach will vary by building and climate, these findings indicate that savings on the order of 50% and greater are not possible without an IS approach. It is therefore recommended that the IS approach be universally adopted to achieve deep energy savings.« less

  6. Kosol Kiatreungwattana | NREL

    Science.gov Websites

    Kosol Kiatreungwattana Kosol Kiatreungwattana Senior Engineer - Building and Renewable Energy experience in building energy systems and renewable technologies, building energy codes, LEED certified projects, sustainable high performance building design, building energy simulation analysis/optimization

  7. Cost-Effectiveness Analysis of the Residential Provisions of the 2015 IECC for the District of Columbia

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mendon, Vrushali V.; Zhao, Mingjie; Taylor, Zachary T.

    2016-02-15

    The 2015 IECC provides cost-effective savings for residential buildings in the District of Columbia. Moving to the 2015 IECC from the 2013 Washington DC Code base code is cost-effective for residential buildings in all climate zones in the District of Columbia.

  8. 76 FR 57982 - Building Energy Codes Cost Analysis

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-19

    ... DEPARTMENT OF ENERGY Office of Energy Efficiency and Renewable Energy [Docket No. EERE-2011-BT-BC-0046] Building Energy Codes Cost Analysis Correction In notice document 2011-23236 beginning on page... heading ``Table 1. Cash flow components'' should read ``Table 7. Cash flow components''. [FR Doc. C1-2011...

  9. Alternative Fuels Data Center: Codes and Standards Basics

    Science.gov Websites

    , the American National Standards Institute regulates how organizations publish codes and standards standards. Legal Enforcement Codes and standards are legally enforceable when jurisdictions adopt them by reference or direct incorporation into their regulations. When jurisdictions adopt codes, they also adopt

  10. Building a standards-based and collaborative e-prescribing tool: MyRxPad.

    PubMed

    Nelson, Stuart J; Zeng, Kelly; Kilbourne, John

    2011-01-01

    MyRxPad (rxp.nlm.nih.gov) is a prototype application intended to enable a practitioner-patient collaborative approach towards e-prescribing: patients play an active role by maintaining up-to-date and accurate medication lists. Prescribers make well-informed and safe prescribing decisions based on personal medication records contributed by patients. MyRxPad is thus the vehicle for collaborations with patients using MyMedicationList (MML). Integration with personal medication records in the context of e-prescribing is thus enabled. We present our experience in applying RxNorm in an e-prescribing setting: using standard names and codes to capture prescribed medication as well as extracting information from RxNorm to support medication-related clinical decision.

  11. Progress Towards Highly Efficient Windows for Zero—Energy Buildings

    NASA Astrophysics Data System (ADS)

    Selkowitz, Stephen

    2008-09-01

    Energy efficient windows could save 4 quads/year, with an additional 1 quad/year gain from daylighting in commercial buildings. This corresponds to 13% of energy used by US buildings and 5% of all energy used by the US. The technical potential is thus very large and the economic potential is slowly becoming a reality. This paper describes the progress in energy efficient windows that employ low-emissivity glazing, electrochromic switchable coatings and other novel materials. Dynamic systems are being developed that use sensors and controls to modulate daylighting and shading contributions in response to occupancy, comfort and energy needs. Improving the energy performance of windows involves physics in a variety of application: optics, heat transfer, materials science and applied engineering. Technical solutions must also be compatible with national policy, codes and standards, economics, business practice and investment, real and perceived risks, comfort, health, safety, productivity, amenities, and occupant preference and values. The challenge is to optimize energy performance by understanding and reinforcing the synergetic coupling between these many issues.

  12. Infill Walls Contribution on the Progressive Collapse Resistance of a Typical Mid-rise RC Framed Building

    NASA Astrophysics Data System (ADS)

    Besoiu, Teodora; Popa, Anca

    2017-10-01

    This study investigates the effect of the autoclaved aerated concrete infill walls on the progressive collapse resistance of a typical RC framed structure. The 13-storey building located in Brăila (a zone with high seismic risk in Romania) was designed according to the former Romanian seismic code P13-70 (1970). Two models of the structure are generated in the Extreme Loading® for Structures computer software: a model with infill walls and a model without infill walls. Following GSA (2003) Guidelines, a nonlinear dynamic procedure is used to determine the progressive collapse risk of the building when a first-storey corner column is suddenly removed. It was found that, the structure is not expected to fail under the standard GSA loading: DL+0.25LL. Moreover, if the infill walls are introduced in the model, the maximum vertical displacement of the node above the removed column is reduced by about 48%.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Malley, Kathleen; Lopez, Hugo; Cairns, Julie

    An overview of the main North American codes and standards associated with hydrogen safety sensors is provided. The distinction between a code and a standard is defined, and the relationship between standards and codes is clarified, especially for those circumstances where a standard or a certification requirement is explicitly referenced within a code. The report identifies three main types of standards commonly applied to hydrogen sensors (interface and controls standards, shock and hazard standards, and performance-based standards). The certification process and a list and description of the main standards and model codes associated with the use of hydrogen safety sensorsmore » in hydrogen infrastructure are presented.« less

  14. 78 FR 27906 - Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings; Notice of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-13

    ... construction (NAICS code 236), e.g., commercial building construction, industrial building construction, commercial and institutional building construction, building finishing contractors, drywall and insulation... Lead; Renovation, Repair, and Painting Program for Public and Commercial Buildings; Notice of Public...

  15. Assessment of codes, by-laws and regulations relating to air wells in building design

    NASA Astrophysics Data System (ADS)

    Fadzil, Sharifah Fairuz Syed; Karamazaman, Nazli

    2017-10-01

    Codes and by-laws concerning air well design (for buildings and lavatories) in Malaysia has been established in the Malaysian Uniform Building By-Laws UBBL number 40 (1) and (2) since the 1980s. Wells are there to fulfill the ventilation and daylighting requirements. The minimum well area according to building storey height are compared between UBBL and the Singapore's well requirements from the Building Construction Authority BCA. A visual and graphical representation (with schematics building and well diagrams drawn to scale) of the minimum well sizes and dimensions is given. It can be seen that if the minimum requirement of well size is used for buildings above 8 storeys high, a thin well resulted which is not proportionate to the building height. A proposed dimension is graphed and given to be used in the UBBL which translated to graphics (3 dimensional buildings drawn to scale) created a much better well proportion.

  16. Indoor air quality and the law in Singapore.

    PubMed

    Chan, P

    1999-12-01

    With the greater use of air-conditioned offices in Singapore, achieving good indoor air quality has become an important issue. The laws that impose duties upon designers and contractors with respect to the design and construction of air-conditioning and mechanical ventilation (ACMV) systems are set out in the Building Control Regulations and the Singapore Standard Code of Practice for Mechanical Ventilation and Air-conditioning in Buildings (hereinafter "SS CP 13:1980"). ACMV maintenance is governed by the Environmental Public Health Act, the Building and Common Property (Maintenance and Management) Act, and the Land Titles (Strata) Act, as well as by lease or tenancy agreements. Designers, contractors, developers, building owners and management corporations may also be liable to the workers, occupants and other premises users for indoor air quality (IAQ)-related injuries under the general principles of contract and tort. Recently, the Guidelines for Good Indoor Air Quality in Office Premises was issued by the Ministry of Environment to complement SS CP 13:1980 toward improving the indoor air quality of air-conditioned office premises. Although the Guidelines have no statutory effect, they may be adopted as contractual requirements in construction, lease and maintenance contracts. They may also be used to determine the relevant standard of duty of care required to discharge tortious liability. This paper looks at the existing laws and rules affecting the design, construction and maintenance of air-conditioned offices in light of Part III of the Ministry's Guidelines.

  17. Dynamics simulation and controller interfacing for legged robots

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reichler, J.A.; Delcomyn, F.

    2000-01-01

    Dynamics simulation can play a critical role in the engineering of robotic control code, and there exist a variety of strategies both for building physical models and for interacting with these models. This paper presents an approach to dynamics simulation and controller interfacing for legged robots, and contrasts it to existing approaches. The authors describe dynamics algorithms and contact-resolution strategies for multibody articulated mobile robots based on the decoupled tree-structure approach, and present a novel scripting language that provides a unified framework for control-code interfacing, user-interface design, and data analysis. Special emphasis is placed on facilitating the rapid integration ofmore » control algorithms written in a standard object-oriented language (C++), the production of modular, distributed, reusable controllers, and the use of parameterized signal-transmission properties such as delay, sampling rate, and noise.« less

  18. Evaluation of liquefaction potential for building code

    NASA Astrophysics Data System (ADS)

    Nunziata, C.; De Nisco, G.; Panza, G. F.

    2008-07-01

    The standard approach for the evaluation of the liquefaction susceptibility is based on the estimation of a safety factor between the cyclic shear resistance to liquefaction and the earthquake induced shear stress. Recently, an updated procedure based on shear-wave velocities (Vs) has been proposed which could be more easily applied. These methods have been applied at La Plaja beach of Catania, that experienced liquefaction because of the 1693 earthquake. The detailed geotechnical and Vs information and the realistic ground motion computed for the 1693 event let us compare the two approaches. The successful application of the Vs procedure, slightly modified to fit historical and safety factor information, even if additional field performances are needed, encourages the development of a guide for liquefaction potential analysis, based on well defined Vs profiles to be included in the italian seismic code.

  19. Legacy Code Modernization

    NASA Technical Reports Server (NTRS)

    Hribar, Michelle R.; Frumkin, Michael; Jin, Haoqiang; Waheed, Abdul; Yan, Jerry; Saini, Subhash (Technical Monitor)

    1998-01-01

    Over the past decade, high performance computing has evolved rapidly; systems based on commodity microprocessors have been introduced in quick succession from at least seven vendors/families. Porting codes to every new architecture is a difficult problem; in particular, here at NASA, there are many large CFD applications that are very costly to port to new machines by hand. The LCM ("Legacy Code Modernization") Project is the development of an integrated parallelization environment (IPE) which performs the automated mapping of legacy CFD (Fortran) applications to state-of-the-art high performance computers. While most projects to port codes focus on the parallelization of the code, we consider porting to be an iterative process consisting of several steps: 1) code cleanup, 2) serial optimization,3) parallelization, 4) performance monitoring and visualization, 5) intelligent tools for automated tuning using performance prediction and 6) machine specific optimization. The approach for building this parallelization environment is to build the components for each of the steps simultaneously and then integrate them together. The demonstration will exhibit our latest research in building this environment: 1. Parallelizing tools and compiler evaluation. 2. Code cleanup and serial optimization using automated scripts 3. Development of a code generator for performance prediction 4. Automated partitioning 5. Automated insertion of directives. These demonstrations will exhibit the effectiveness of an automated approach for all the steps involved with porting and tuning a legacy code application for a new architecture.

  20. Understanding Energy Code Acceptance within the Alaska Building Community

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mapes, Terry S.

    2012-02-14

    This document presents the technical assistance provided to the Alaska Home Financing Corporation on behalf of PNNL regarding the assessment of attitudes toward energy codes within the building community in Alaska. It includes a summary of the existing situation and specific assistance requested by AHFC, the results of a questionnaire designed for builders surveyed in a suburban area of Anchorage, interviews with a lender, a building official, and a research specialist, and recommendations for future action by AHFC.

  1. Probability-Based Design Criteria of the ASCE 7 Tsunami Loads and Effects Provisions (Invited)

    NASA Astrophysics Data System (ADS)

    Chock, G.

    2013-12-01

    Mitigation of tsunami risk requires a combination of emergency preparedness for evacuation in addition to providing structural resilience of critical facilities, infrastructure, and key resources necessary for immediate response and economic and social recovery. Critical facilities would include emergency response, medical, tsunami refuges and shelters, ports and harbors, lifelines, transportation, telecommunications, power, financial institutions, and major industrial/commercial facilities. The Tsunami Loads and Effects Subcommittee of the ASCE/SEI 7 Standards Committee is developing a proposed new Chapter 6 - Tsunami Loads and Effects for the 2016 edition of the ASCE 7 Standard. ASCE 7 provides the minimum design loads and requirements for structures subject to building codes such as the International Building Code utilized in the USA. In this paper we will provide a review emphasizing the intent of these new code provisions and explain the design methodology. The ASCE 7 provisions for Tsunami Loads and Effects enables a set of analysis and design methodologies that are consistent with performance-based engineering based on probabilistic criteria. . The ASCE 7 Tsunami Loads and Effects chapter will be initially applicable only to the states of Alaska, Washington, Oregon, California, and Hawaii. Ground shaking effects and subsidence from a preceding local offshore Maximum Considered Earthquake will also be considered prior to tsunami arrival for Alaska and states in the Pacific Northwest regions governed by nearby offshore subduction earthquakes. For national tsunami design provisions to achieve a consistent reliability standard of structural performance for community resilience, a new generation of tsunami inundation hazard maps for design is required. The lesson of recent tsunami is that historical records alone do not provide a sufficient measure of the potential heights of future tsunamis. Engineering design must consider the occurrence of events greater than scenarios in the historical record, and should properly be based on the underlying seismicity of subduction zones. Therefore, Probabilistic Tsunami Hazard Analysis (PTHA) consistent with source seismicity must be performed in addition to consideration of historical event scenarios. A method of Probabilistic Tsunami Hazard Analysis has been established that is generally consistent with Probabilistic Seismic Hazard Analysis in the treatment of uncertainty. These new tsunami design zone maps will define the coastal zones where structures of greater importance would be designed for tsunami resistance and community resilience. Structural member acceptability criteria will be based on performance objectives for a 2,500-year Maximum Considered Tsunami. The approach developed by the ASCE Tsunami Loads and Effects Subcommittee of the ASCE 7 Standard would result in the first national unification of tsunami hazard criteria for design codes reflecting the modern approach of Performance-Based Engineering.

  2. Impacts of temperature and its variability on mortality in New England

    NASA Astrophysics Data System (ADS)

    Shi, Liuhua; Kloog, Itai; Zanobetti, Antonella; Liu, Pengfei; Schwartz, Joel D.

    2015-11-01

    Rapid build-up of greenhouse gases is expected to increase Earth’s mean surface temperature, with unclear effects on temperature variability. This makes understanding the direct effects of a changing climate on human health more urgent. However, the effects of prolonged exposures to variable temperatures, which are important for understanding the public health burden, are unclear. Here we demonstrate that long-term survival was significantly associated with both seasonal mean values and standard deviations of temperature among the Medicare population (aged 65+) in New England, and break that down into long-term contrasts between ZIP codes and annual anomalies. A rise in summer mean temperature of 1 °C was associated with a 1.0% higher death rate, whereas an increase in winter mean temperature corresponded to a 0.6% decrease in mortality. Increases in standard deviations of temperature for both summer and winter were harmful. The increased mortality in warmer summers was entirely due to anomalies, whereas it was long-term average differences in the standard deviation of summer temperatures across ZIP codes that drove the increased risk. For future climate scenarios, seasonal mean temperatures may in part account for the public health burden, but the excess public health risk of climate change may also stem from changes of within-season temperature variability.

  3. Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratton, J. Chris; Singer, Brett C.

    2014-01-01

    Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report by Lawrence Berkeley National Laboratory identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two meetings and provided input and feedback to early drafts ofmore » this document. The most fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most U.S. locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.« less

  4. Addressing Kitchen Contaminants for Healthy, Low-Energy Homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stratton, J. Chris; Singer, Brett C.

    2014-01-01

    Cooking and cooking burners emit pollutants that can adversely affect indoor air quality in residences and significantly impact occupant health. Effective kitchen exhaust ventilation can reduce exposure to cooking-related air pollutants as an enabling step to healthier, low-energy homes. This report identifies barriers to the widespread adoption of kitchen exhaust ventilation technologies and practice and proposes a suite of strategies to overcome these barriers. The recommendations have been vetted by a group of industry, regulatory, health, and research experts and stakeholders who convened for two web-based meetings and provided input and feedback to early drafts of this document. The mostmore » fundamental barriers are (1) the common misconception, based on a sensory perception of risk, that kitchen exhaust when cooking is unnecessary and (2) the lack of a code requirement for kitchen ventilation in most US locations. Highest priority objectives include the following: (1) Raise awareness among the public and the building industry of the need to install and routinely use kitchen ventilation; (2) Incorporate kitchen exhaust ventilation as a requirement of building codes and improve the mechanisms for code enforcement; (3) Provide best practice product and use-behavior guidance to ventilation equipment purchasers and installers, and; (4) Develop test methods and performance targets to advance development of high performance products. A specific, urgent need is the development of an over-the-range microwave that meets the airflow and sound requirements of ASHRAE Standard 62.2.« less

  5. 78 FR 47677 - DOE Activities and Methodology for Assessing Compliance With Building Energy Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-06

    ... construction. Post- construction evaluations were implemented in one study in an effort to reduce these costs... these pilot studies have led to a number of recommendations and potential changes to the DOE methodology... fundamental assumptions and approaches to measuring compliance with building energy codes. This notice...

  6. Learning by Doing: Teaching Decision Making through Building a Code of Ethics.

    ERIC Educational Resources Information Center

    Hawthorne, Mark D.

    2001-01-01

    Notes that applying abstract ethical principles to the practical business of building a code of applied ethics for a technical communication department teaches students that they share certain unarticulated or unconscious values that they can translate into ethical principles. Suggests that combining abstract theory with practical policy writing…

  7. 75 FR 9434 - Civil Rights Division, Disability Rights Section; Agency Information Collection Activities Under...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... Rights (or his or her designee) may certify that a State or local building code or similar ordinance that establishes accessibility requirements (Code) meets or exceeds the minimum requirements of the ADA for..., Policy and Planning Staff, Justice Management Division, Patrick Henry Building, Suite 1600, 601 D Street...

  8. 75 FR 27816 - Civil Rights Division, Disability Rights Section; Agency Information Collection Activities Under...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-18

    ... certify that a State or local building code or similar ordinance that establishes accessibility requirements (Code) meets or exceeds the minimum requirements of the ADA for accessibility and usability of... Management Division, Patrick Henry Building, Suite 1600, 601 D Street, NW., Washington, DC 20530. Dated: May...

  9. VS30 – A site-characterization parameter for use in building Codes, simplified earthquake resistant design, GMPEs, and ShakeMaps

    USGS Publications Warehouse

    Borcherdt, Roger D.

    2012-01-01

    VS30, defined as the average seismic shear-wave velocity from the surface to a depth of 30 meters, has found wide-spread use as a parameter to characterize site response for simplified earthquake resistant design as implemented in building codes worldwide. VS30 , as initially introduced by the author for the US 1994 NEHRP Building Code, provides unambiguous definitions of site classes and site coefficients for site-dependent response spectra based on correlations derived from extensive borehole logging and comparative ground-motion measurement programs in California. Subsequent use of VS30 for development of strong ground motion prediction equations (GMPEs) and measurement of extensive sets of VS borehole data have confirmed the previous empirical correlations and established correlations of SVS30 with VSZ at other depths. These correlations provide closed form expressions to predict S30 V at a large number of additional sites and further justify S30 V as a parameter to characterize site response for simplified building codes, GMPEs, ShakeMap, and seismic hazard mapping.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    Frost-protected shallow foundations (FPSFs) offer a proven technology designed to substantially lower construction costs in colder climates, enhancing housing affordability for families in many parts of the United States. This document provides step-by-step procedures to assist building professionals in designing and laying a slab- on-grade FPSF. FPSFs save money over conventional designs by requiring less excavation to construct a frost-proof foundation. It is specially insulated along its perimeter to raise the temperature of the surrounding ground and decrease frost penetration, thus allowing for the construction of a substantially shallower foundation. The FPSF is considered standard practice for homes in Scandinavia,more » where 40 years of field testing has proven it to be economical to construct, durable, and energy efficient. HUD strongly encourages wide spread adoption of FPSF technology in the United States and its incorporation into major model building codes.« less

  11. Wood: a construction material for tall buildings

    NASA Astrophysics Data System (ADS)

    Wimmers, Guido

    2017-12-01

    Wood has great potential as a building material, because it is strong and lightweight, environmentally friendly and can be used in prefabricated buildings. However, only changes in building codes will make wood competitive with steel and concrete.

  12. Standard interface files and procedures for reactor physics codes, version III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carmichael, B.M.

    Standards and procedures for promoting the exchange of reactor physics codes are updated to Version-III status. Standards covering program structure, interface files, file handling subroutines, and card input format are included. The implementation status of the standards in codes and the extension of the standards to new code areas are summarized. (15 references) (auth)

  13. Energy analysis of cool, medium, and dark roofs on residential buildings in the U.S

    NASA Astrophysics Data System (ADS)

    Dunbar, Michael A.

    This study reports an energy analysis of cool, medium, and dark roofs on residential buildings in the U.S. Three analyses were undertaken in this study: energy consumption, economic analysis, and an environmental analysis. The energy consumption reports the electricity and natural gas consumption of the simulations. The economic analysis uses tools such as simple payback period (SPP) and net present value (NPV) to determine the profitability of the cool roof and the medium roof. The variable change for each simulation model was the roof color. The default color was a dark roof and the results were focused on the changes produced by the cool roof and the medium roof. The environmental analysis uses CO2 emissions to assess the environmental impact of the cool roof and the medium roof. The analysis uses the U.S. Department of Energy (DOE) EnergyPlus software to produce simulations of a typical, two-story residential home in the U.S. The building details of the typical, two-story U.S. residential home and the International Energy Conservation Code (IECC) building code standards used are discussed in this study. This study indicates that, when material and labor costs are. assessed, the cool roof and the medium roof do not yield a SPP less than 10 years. Furthermore, the NPV results assess that neither the cool roof nor the medium roof are a profitable investment in any climate zone in the U.S. The environmental analysis demonstrates that both the cool roof and the medium roof have a positive impact in warmer climates by reducing the CO2 emissions as much as 264 kg and 129 kg, respectively.

  14. Documentation for the Southeast Asia seismic hazard maps

    USGS Publications Warehouse

    Petersen, Mark; Harmsen, Stephen; Mueller, Charles; Haller, Kathleen; Dewey, James; Luco, Nicolas; Crone, Anthony; Lidke, David; Rukstales, Kenneth

    2007-01-01

    The U.S. Geological Survey (USGS) Southeast Asia Seismic Hazard Project originated in response to the 26 December 2004 Sumatra earthquake (M9.2) and the resulting tsunami that caused significant casualties and economic losses in Indonesia, Thailand, Malaysia, India, Sri Lanka, and the Maldives. During the course of this project, several great earthquakes ruptured subduction zones along the southern coast of Indonesia (fig. 1) causing additional structural damage and casualties in nearby communities. Future structural damage and societal losses from large earthquakes can be mitigated by providing an advance warning of tsunamis and introducing seismic hazard provisions in building codes that allow buildings and structures to withstand strong ground shaking associated with anticipated earthquakes. The Southeast Asia Seismic Hazard Project was funded through a United States Agency for International Development (USAID)—Indian Ocean Tsunami Warning System to develop seismic hazard maps that would assist engineers in designing buildings that will resist earthquake strong ground shaking. An important objective of this project was to discuss regional hazard issues with building code officials, scientists, and engineers in Thailand, Malaysia, and Indonesia. The code communities have been receptive to these discussions and are considering updating the Thailand and Indonesia building codes to incorporate new information (for example, see notes from Professor Panitan Lukkunaprasit, Chulalongkorn University in Appendix A).

  15. MAN-004 Design Standards Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Timothy L.

    2014-07-01

    At Sandia National Laboratories in New Mexico (SNL/NM), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/NM applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. Themore » safety and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule. These design standards generally apply to all disciplines on all SNL/NM projects. Architectural and engineering design must be both functional and cost-effective. Facility design must be tailored to fit its intended function, while emphasizing low-maintenance, energy-efficient, and energy-conscious design. Design facilities that can be maintained easily, with readily accessible equipment areas, low maintenance, and quality systems. To promote an orderly and efficient appearance, architectural features of new facilities must complement and enhance the existing architecture at the site. As an Architectural and Engineering (A/E) professional, you must advise the Project Manager when this approach is prohibitively expensive. You are encouraged to use professional judgment and ingenuity to produce a coordinated interdisciplinary design that is cost-effective, easily contractible or buildable, high-performing, aesthetically pleasing, and compliant with applicable building codes. Close coordination and development of civil, landscape, structural, architectural, fire protection, mechanical, electrical, telecommunications, and security features is expected to ensure compatibility with planned functional equipment and to facilitate constructability. If portions of the design are subcontracted to specialists, delivery of the finished design documents must not be considered complete until the subcontracted portions are also submitted for review. You must, along with support consultants, perform functional analyses and programming in developing design solutions. These solutions must reflect coordination of the competing functional, budgetary, and physical requirements for the project. During design phases, meetings between you and the SNL/NM Project Team to discuss and resolve design issues are required. These meetings are a normal part of the design process. For specific design-review requirements, see the project-specific Design Criteria. In addition to the design requirements described in this manual, instructive information is provided to explain the sustainable building practice goals for design, construction, operation, and maintenance of SNL/NM facilities. Please notify SNL/NM personnel of design best practices not included in this manual, so they can be incorporated in future updates.« less

  16. Recommendations on Implementing the Energy Conservation Building Code in Rajasthan, India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Makela, Eric J.; Evans, Meredydd

    India launched the Energy Conservation Building Code (ECBC) in 2007 and Indian Bureau of Energy Efficiency (BEE) recently indicated that it would move to mandatory implementation in the 12th Five-Year Plan. The State of Rajasthan adopted ECBC with minor modifications; the new regulation is known as the Energy Conservation Building Directives – Rajasthan 2011 (ECBD-R). It became mandatory in Rajasthan on September 28, 2011. This report provides recommendations on an ECBD-R enforcement roadmap for the State of Rajasthan.

  17. SEER*Educate: Use of Abstracting Quality Index Scores to Monitor Improvement of All Employees.

    PubMed

    Potts, Mary S; Scott, Tim; Hafterson, Jennifer L

    2016-01-01

    Integral parts of the Seattle-Puget Sound's Cancer Surveillance System registry's continuous improvement model include the incorporation of SEER*Educate into its training program for all staff and analyzing assessment results using the Abstracting Quality Index (AQI). The AQI offers a comprehensive measure of overall performance in SEER*Educate, which is a Web-based application used to personalize learning and diagnostically pinpoint each staff member's place on the AQI continuum. The assessment results are tallied from 6 abstracting standards within 2 domains: incidence reporting and coding accuracy. More than 100 data items are aligned to 1 or more of the 6 standards to build an aggregated score that is placed on a continuum for continuous improvement. The AQI score accurately identifies those individuals who have a good understanding of how to apply the 6 abstracting standards to reliably generate high quality abstracts.

  18. MDSplus quality improvement project

    DOE PAGES

    Fredian, Thomas W.; Stillerman, Joshua; Manduchi, Gabriele; ...

    2016-05-31

    MDSplus is a data acquisition and analysis system used worldwide predominantly in the fusion research community. Development began 29 years ago on the OpenVMS operating system. Since that time there have been many new features added and the code has been ported to many different operating systems. There have been contributions to the MDSplus development from the fusion community in the way of feature suggestions, feature implementations, documentation and porting to different operating systems. The bulk of the development and support of MDSplus, however, has been provided by a relatively small core developer group of three or four members. Givenmore » the size of the development team and the large number of users much more effort was focused on providing new features for the community than on keeping the underlying code and documentation up to date with the evolving software development standards. To ensure that MDSplus will continue to provide the needs of the community in the future, the MDSplus development team along with other members of the MDSplus user community has commenced on a major quality improvement project. The planned improvements include changes to software build scripts to better use GNU Autoconf and Automake tools, refactoring many of the source code modules using new language features available in modern compilers, using GNU MinGW-w64 to create MS Windows distributions, migrating to a more modern source code management system, improvement of source documentation as well as improvements to the www.mdsplus.org web site documentation and layout, and the addition of more comprehensive test suites to apply to MDSplus code builds prior to releasing installation kits to the community. This paper should lead to a much more robust product and establish a framework to maintain stability as more enhancements and features are added. Finally, this paper will describe these efforts that are either in progress or planned for the near future.« less

  19. Open-Source Python Tools for Deploying Interactive GIS Dashboards for a Billion Datapoints on a Laptop

    NASA Astrophysics Data System (ADS)

    Steinberg, P. D.; Bednar, J. A.; Rudiger, P.; Stevens, J. L. R.; Ball, C. E.; Christensen, S. D.; Pothina, D.

    2017-12-01

    The rich variety of software libraries available in the Python scientific ecosystem provides a flexible and powerful alternative to traditional integrated GIS (geographic information system) programs. Each such library focuses on doing a certain set of general-purpose tasks well, and Python makes it relatively simple to glue the libraries together to solve a wide range of complex, open-ended problems in Earth science. However, choosing an appropriate set of libraries can be challenging, and it is difficult to predict how much "glue code" will be needed for any particular combination of libraries and tasks. Here we present a set of libraries that have been designed to work well together to build interactive analyses and visualizations of large geographic datasets, in standard web browsers. The resulting workflows run on ordinary laptops even for billions of data points, and easily scale up to larger compute clusters when available. The declarative top-level interface used in these libraries means that even complex, fully interactive applications can be built and deployed as web services using only a few dozen lines of code, making it simple to create and share custom interactive applications even for datasets too large for most traditional GIS systems. The libraries we will cover include GeoViews (HoloViews extended for geographic applications) for declaring visualizable/plottable objects, Bokeh for building visual web applications from GeoViews objects, Datashader for rendering arbitrarily large datasets faithfully as fixed-size images, Param for specifying user-modifiable parameters that model your domain, Xarray for computing with n-dimensional array data, Dask for flexibly dispatching computational tasks across processors, and Numba for compiling array-based Python code down to fast machine code. We will show how to use the resulting workflow with static datasets and with simulators such as GSSHA or AdH, allowing you to deploy flexible, high-performance web-based dashboards for your GIS data or simulations without needing major investments in code development or maintenance.

  20. New Site Coefficients and Site Classification System Used in Recent Building Seismic Code Provisions

    USGS Publications Warehouse

    Dobry, R.; Borcherdt, R.D.; Crouse, C.B.; Idriss, I.M.; Joyner, W.B.; Martin, G.R.; Power, M.S.; Rinne, E.E.; Seed, R.B.

    2000-01-01

    Recent code provisions for buildings and other structures (1994 and 1997 NEHRP Provisions, 1997 UBC) have adopted new site amplification factors and a new procedure for site classification. Two amplitude-dependent site amplification factors are specified: Fa for short periods and Fv for longer periods. Previous codes included only a long period factor S and did not provide for a short period amplification factor. The new site classification system is based on definitions of five site classes in terms of a representative average shear wave velocity to a depth of 30 m (V?? s). This definition permits sites to be classified unambiguously. When the shear wave velocity is not available, other soil properties such as standard penetration resistance or undrained shear strength can be used. The new site classes denoted by letters A - E, replace site classes in previous codes denoted by S1 - S4. Site classes A and B correspond to hard rock and rock, Site Class C corresponds to soft rock and very stiff / very dense soil, and Site Classes D and E correspond to stiff soil and soft soil. A sixth site class, F, is defined for soils requiring site-specific evaluations. Both Fa and Fv are functions of the site class, and also of the level of seismic hazard on rock, defined by parameters such as Aa and Av (1994 NEHRP Provisions), Ss and S1 (1997 NEHRP Provisions) or Z (1997 UBC). The values of Fa and Fv decrease as the seismic hazard on rock increases due to soil nonlinearity. The greatest impact of the new factors Fa and Fv as compared with the old S factors occurs in areas of low-to-medium seismic hazard. This paper summarizes the new site provisions, explains the basis for them, and discusses ongoing studies of site amplification in recent earthquakes that may influence future code developments.

  1. Continuous Codes and Standards Improvement (CCSI)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rivkin, Carl H; Burgess, Robert M; Buttner, William J

    2015-10-21

    As of 2014, the majority of the codes and standards required to initially deploy hydrogen technologies infrastructure in the United States have been promulgated. These codes and standards will be field tested through their application to actual hydrogen technologies projects. Continuous codes and standards improvement (CCSI) is a process of identifying code issues that arise during project deployment and then developing codes solutions to these issues. These solutions would typically be proposed amendments to codes and standards. The process is continuous because as technology and the state of safety knowledge develops there will be a need to monitor the applicationmore » of codes and standards and improve them based on information gathered during their application. This paper will discuss code issues that have surfaced through hydrogen technologies infrastructure project deployment and potential code changes that would address these issues. The issues that this paper will address include (1) setback distances for bulk hydrogen storage, (2) code mandated hazard analyses, (3) sensor placement and communication, (4) the use of approved equipment, and (5) system monitoring and maintenance requirements.« less

  2. Evaluation of Force Transfer Around Openings - Experimental and Analytical Studies

    Treesearch

    Borjen Yeh; Tom Skaggs; Frank Lam; Minghao Li; Douglas Rammer; James Wacker

    2011-01-01

    Wood structural panel (WSP) sheathed shear walls and diaphragms are the primary lateral-load-resistingelements in wood-frame construction. The historical performance of light-frame structures in North America is very good due, in part, to model building codes that are designed to safeguard life safety. These model building codes have spawned continual improvement and...

  3. Modelling Force Transfer Around Openings of Full-Scale Shear Walls

    Treesearch

    Tom Skaggs; Borjen Yeh; Frank Lam; Minghao Li; Doug Rammer; James Wacker

    2011-01-01

    Wood structural panel (WSP) sheathed shear walls and diaphragms are the primary lateralload-resisting elements in wood-frame construction. The historical performance of lightframe structures in North America has been very good due, in part, to model building codes that are designed to preserve life safety. These model building codes have spawned continual improvement...

  4. Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

    DOE PAGES

    Kim, Dongsu; Cox, Sam J.; Cho, Heejin; ...

    2017-05-22

    Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less

  5. Evaluation of energy savings potential of variable refrigerant flow (VRF) from variable air volume (VAV) in the U.S. climate locations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dongsu; Cox, Sam J.; Cho, Heejin

    Variable refrigerant flow (VRF) systems are known for their high energy performance and thus can improve energy efficiency both in residential and commercial buildings. The energy savings potential of this system has been demonstrated in several studies by comparing the system performance with conventional HVAC systems such as rooftop variable air volume systems (RTU-VAV) and central chiller and boiler systems. This paper evaluates the performance of VRF and RTU-VAV systems in a simulation environment using widely-accepted whole building energy modeling software, EnergyPlus. A medium office prototype building model, developed by the U.S. Department of Energy (DOE), is used to assessmore » the performance of VRF and RTU-VAV systems. Each system is placed in 16 different locations, representing all U.S. climate zones, to evaluate the performance variations. Both models are compliant with the minimum energy code requirements prescribed in ASHRAE standard 90.1-2010 — energy standard for buildings except low-rise residential buildings. Finally, a comparison study between the simulation results of VRF and RTU-VAV models is made to demonstrate energy savings potential of VRF systems. The simulation results show that the VRF systems would save around 15–42% and 18–33% for HVAC site and source energy uses compared to the RTU-VAV systems. In addition, calculated results for annual HVAC cost savings point out that hot and mild climates show higher percentage cost savings for the VRF systems than cold climates mainly due to the differences in electricity and gas use for heating sources.« less

  6. Integration of nursing assessment concepts into the medical entities dictionary using the LOINC semantic structure as a terminology model.

    PubMed

    Cieslowski, B J; Wajngurt, D; Cimino, J J; Bakken, S

    2001-01-01

    Recent investigations have tested the applicability of various terminology models for the representing nursing concepts including those related to nursing diagnoses, nursing interventions, and standardized nursing assessments as a prerequisite for building a reference terminology that supports the nursing domain. We used the semantic structure of Clinical LOINC (Logical Observations, Identifiers, Names, and Codes) as a reference terminology model to support the integration of standardized assessment terms from two nursing terminologies into the Medical Entities Dictionary (MED), the concept-oriented, metadata dictionary at New York Presbyterian Hospital. Although the LOINC semantic structure was used previously to represent laboratory terms in the MED, selected hierarchies and semantic slots required revisions in order to incorporate the nursing assessment concepts. This project was an initial step in integrating nursing assessment concepts into the MED in a manner consistent with evolving standards for reference terminology models. Moreover, the revisions provide the foundation for adding other types of standardized assessments to the MED.

  7. Integration of nursing assessment concepts into the medical entities dictionary using the LOINC semantic structure as a terminology model.

    PubMed Central

    Cieslowski, B. J.; Wajngurt, D.; Cimino, J. J.; Bakken, S.

    2001-01-01

    Recent investigations have tested the applicability of various terminology models for the representing nursing concepts including those related to nursing diagnoses, nursing interventions, and standardized nursing assessments as a prerequisite for building a reference terminology that supports the nursing domain. We used the semantic structure of Clinical LOINC (Logical Observations, Identifiers, Names, and Codes) as a reference terminology model to support the integration of standardized assessment terms from two nursing terminologies into the Medical Entities Dictionary (MED), the concept-oriented, metadata dictionary at New York Presbyterian Hospital. Although the LOINC semantic structure was used previously to represent laboratory terms in the MED, selected hierarchies and semantic slots required revisions in order to incorporate the nursing assessment concepts. This project was an initial step in integrating nursing assessment concepts into the MED in a manner consistent with evolving standards for reference terminology models. Moreover, the revisions provide the foundation for adding other types of standardized assessments to the MED. PMID:11825165

  8. ADEpedia: a scalable and standardized knowledge base of Adverse Drug Events using semantic web technology.

    PubMed

    Jiang, Guoqian; Solbrig, Harold R; Chute, Christopher G

    2011-01-01

    A source of semantically coded Adverse Drug Event (ADE) data can be useful for identifying common phenotypes related to ADEs. We proposed a comprehensive framework for building a standardized ADE knowledge base (called ADEpedia) through combining ontology-based approach with semantic web technology. The framework comprises four primary modules: 1) an XML2RDF transformation module; 2) a data normalization module based on NCBO Open Biomedical Annotator; 3) a RDF store based persistence module; and 4) a front-end module based on a Semantic Wiki for the review and curation. A prototype is successfully implemented to demonstrate the capability of the system to integrate multiple drug data and ontology resources and open web services for the ADE data standardization. A preliminary evaluation is performed to demonstrate the usefulness of the system, including the performance of the NCBO annotator. In conclusion, the semantic web technology provides a highly scalable framework for ADE data source integration and standard query service.

  9. Building code challenging the ethics behind adobe architecture in North Cyprus.

    PubMed

    Hurol, Yonca; Yüceer, Hülya; Şahali, Öznem

    2015-04-01

    Adobe masonry is part of the vernacular architecture of Cyprus. Thus, it is possible to use this technology in a meaningful way on the island. On the other hand, although adobe architecture is more sustainable in comparison to other building technologies, the use of it is diminishing in North Cyprus. The application of Turkish building code in the north of the island has created complications in respect of the use of adobe masonry, because this building code demands that reinforced concrete vertical tie-beams are used together with adobe masonry. The use of reinforced concrete elements together with adobe masonry causes problems in relation to the climatic response of the building as well as causing other technical and aesthetic problems. This situation makes the design of adobe masonry complicated and various types of ethical problems also emerge. The objective of this article is to analyse the ethical problems which arise as a consequence of the restrictive character of the building code, by analysing two case studies and conducting an interview with an architect who was involved with the use of adobe masonry in North Cyprus. According to the results of this article there are ethical problems at various levels in the design of both case studies. These problems are connected to the responsibilities of architects in respect of the social benefit, material production, aesthetics and affordability of the architecture as well as presenting distrustful behaviour where the obligations of architects to their clients is concerned.

  10. 30 CFR 57.19093 - Standard signal code.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Standard signal code. 57.19093 Section 57.19093... Signaling § 57.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  11. 30 CFR 57.19093 - Standard signal code.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Standard signal code. 57.19093 Section 57.19093... Signaling § 57.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  12. 30 CFR 56.19093 - Standard signal code.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Standard signal code. 56.19093 Section 56.19093... Signaling § 56.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  13. 30 CFR 56.19093 - Standard signal code.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Standard signal code. 56.19093 Section 56.19093... Signaling § 56.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  14. 48 CFR 452.219-70 - Size Standard and NAICS Code Information.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 4 2010-10-01 2010-10-01 false Size Standard and NAICS Code Information. 452.219-70 Section 452.219-70 Federal Acquisition Regulations System DEPARTMENT OF... System Code(s) and business size standard(s) describing the products and/or services to be acquired under...

  15. 30 CFR 57.19093 - Standard signal code.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Standard signal code. 57.19093 Section 57.19093... Signaling § 57.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  16. 30 CFR 57.19093 - Standard signal code.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Standard signal code. 57.19093 Section 57.19093... Signaling § 57.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  17. 30 CFR 57.19093 - Standard signal code.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Standard signal code. 57.19093 Section 57.19093... Signaling § 57.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  18. 30 CFR 56.19093 - Standard signal code.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Standard signal code. 56.19093 Section 56.19093... Signaling § 56.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  19. 30 CFR 56.19093 - Standard signal code.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Standard signal code. 56.19093 Section 56.19093... Signaling § 56.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  20. 30 CFR 56.19093 - Standard signal code.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Standard signal code. 56.19093 Section 56.19093... Signaling § 56.19093 Standard signal code. A standard code of hoisting signals shall be adopted and used at each mine. The movement of a shaft conveyance on a “one bell” signal is prohibited. ...

  1. SU-D-BRD-03: A Gateway for GPU Computing in Cancer Radiotherapy Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jia, X; Folkerts, M; Shi, F

    Purpose: Graphics Processing Unit (GPU) has become increasingly important in radiotherapy. However, it is still difficult for general clinical researchers to access GPU codes developed by other researchers, and for developers to objectively benchmark their codes. Moreover, it is quite often to see repeated efforts spent on developing low-quality GPU codes. The goal of this project is to establish an infrastructure for testing GPU codes, cross comparing them, and facilitating code distributions in radiotherapy community. Methods: We developed a system called Gateway for GPU Computing in Cancer Radiotherapy Research (GCR2). A number of GPU codes developed by our group andmore » other developers can be accessed via a web interface. To use the services, researchers first upload their test data or use the standard data provided by our system. Then they can select the GPU device on which the code will be executed. Our system offers all mainstream GPU hardware for code benchmarking purpose. After the code running is complete, the system automatically summarizes and displays the computing results. We also released a SDK to allow the developers to build their own algorithm implementation and submit their binary codes to the system. The submitted code is then systematically benchmarked using a variety of GPU hardware and representative data provided by our system. The developers can also compare their codes with others and generate benchmarking reports. Results: It is found that the developed system is fully functioning. Through a user-friendly web interface, researchers are able to test various GPU codes. Developers also benefit from this platform by comprehensively benchmarking their codes on various GPU platforms and representative clinical data sets. Conclusion: We have developed an open platform allowing the clinical researchers and developers to access the GPUs and GPU codes. This development will facilitate the utilization of GPU in radiation therapy field.« less

  2. Development of new methodologies for evaluating the energy performance of new commercial buildings

    NASA Astrophysics Data System (ADS)

    Song, Suwon

    The concept of Measurement and Verification (M&V) of a new building continues to become more important because efficient design alone is often not sufficient to deliver an efficient building. Simulation models that are calibrated to measured data can be used to evaluate the energy performance of new buildings if they are compared to energy baselines such as similar buildings, energy codes, and design standards. Unfortunately, there is a lack of detailed M&V methods and analysis methods to measure energy savings from new buildings that would have hypothetical energy baselines. Therefore, this study developed and demonstrated several new methodologies for evaluating the energy performance of new commercial buildings using a case-study building in Austin, Texas. First, three new M&V methods were developed to enhance the previous generic M&V framework for new buildings, including: (1) The development of a method to synthesize weather-normalized cooling energy use from a correlation of Motor Control Center (MCC) electricity use when chilled water use is unavailable, (2) The development of an improved method to analyze measured solar transmittance against incidence angle for sample glazing using different solar sensor types, including Eppley PSP and Li-Cor sensors, and (3) The development of an improved method to analyze chiller efficiency and operation at part-load conditions. Second, three new calibration methods were developed and analyzed, including: (1) A new percentile analysis added to the previous signature method for use with a DOE-2 calibration, (2) A new analysis to account for undocumented exhaust air in DOE-2 calibration, and (3) An analysis of the impact of synthesized direct normal solar radiation using the Erbs correlation on DOE-2 simulation. Third, an analysis of the actual energy savings compared to three different energy baselines was performed, including: (1) Energy Use Index (EUI) comparisons with sub-metered data, (2) New comparisons against Standards 90.1-1989 and 90.1-2001, and (3) A new evaluation of the performance of selected Energy Conservation Design Measures (ECDMs). Finally, potential energy savings were also simulated from selected improvements, including: minimum supply air flow, undocumented exhaust air, and daylighting.

  3. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  4. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505.1...

  5. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  6. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  7. 10 CFR 434.505 - Reference building method.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Reference building method. 434.505 Section 434.505 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.505 Reference building method. 505...

  8. Overview of the ArbiTER edge plasma eigenvalue code

    NASA Astrophysics Data System (ADS)

    Baver, Derek; Myra, James; Umansky, Maxim

    2011-10-01

    The Arbitrary Topology Equation Reader, or ArbiTER, is a flexible eigenvalue solver that is currently under development for plasma physics applications. The ArbiTER code builds on the equation parser framework of the existing 2DX code, extending it to include a topology parser. This will give the code the capability to model problems with complicated geometries (such as multiple X-points and scrape-off layers) or model equations with arbitrary numbers of dimensions (e.g. for kinetic analysis). In the equation parser framework, model equations are not included in the program's source code. Instead, an input file contains instructions for building a matrix from profile functions and elementary differential operators. The program then executes these instructions in a sequential manner. These instructions may also be translated into analytic form, thus giving the code transparency as well as flexibility. We will present an overview of how the ArbiTER code is to work, as well as preliminary results from early versions of this code. Work supported by the U.S. DOE.

  9. GAMBIT: the global and modular beyond-the-standard-model inference tool

    NASA Astrophysics Data System (ADS)

    Athron, Peter; Balazs, Csaba; Bringmann, Torsten; Buckley, Andy; Chrząszcz, Marcin; Conrad, Jan; Cornell, Jonathan M.; Dal, Lars A.; Dickinson, Hugh; Edsjö, Joakim; Farmer, Ben; Gonzalo, Tomás E.; Jackson, Paul; Krislock, Abram; Kvellestad, Anders; Lundberg, Johan; McKay, James; Mahmoudi, Farvah; Martinez, Gregory D.; Putze, Antje; Raklev, Are; Ripken, Joachim; Rogan, Christopher; Saavedra, Aldo; Savage, Christopher; Scott, Pat; Seo, Seon-Hee; Serra, Nicola; Weniger, Christoph; White, Martin; Wild, Sebastian

    2017-11-01

    We describe the open-source global fitting package GAMBIT: the Global And Modular Beyond-the-Standard-Model Inference Tool. GAMBIT combines extensive calculations of observables and likelihoods in particle and astroparticle physics with a hierarchical model database, advanced tools for automatically building analyses of essentially any model, a flexible and powerful system for interfacing to external codes, a suite of different statistical methods and parameter scanning algorithms, and a host of other utilities designed to make scans faster, safer and more easily-extendible than in the past. Here we give a detailed description of the framework, its design and motivation, and the current models and other specific components presently implemented in GAMBIT. Accompanying papers deal with individual modules and present first GAMBIT results. GAMBIT can be downloaded from gambit.hepforge.org.

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levy, E.; Mullens, M.; Rath, P.

    The Advanced Envelope Research effort will provide factory homebuilders with high performance, cost-effective envelope designs that can be effectively integrated into the plant production process while meeting the thermal requirements of the 2012 IECC standards. This work is part of a multiphase effort. Phase 1 identified seven envelope technologies and provided a preliminary assessment of three methods for building high performance walls. Phase 2 focused on developing viable product designs, manufacturing strategies, addressing code and structural issues, and cost analysis of the three selected options. An industry advisory committee helped narrow the research focus to perfecting a stud wall designmore » with exterior continuous insulation (CI). This report describes Phase 3, which was completed in two stages and continued the design development effort, exploring and evaluating a range or methods for applying CI to factory built homes. The scope also included material selection, manufacturing and cost analysis, and prototyping and testing. During this phase, a home was built with CI, evaluated, and placed in service. The experience of building a mock up wall section with CI and then constructing on line a prototype home resolved important concerns about how to integrate the material into the production process. First steps were taken toward finding least expensive approaches for incorporating CI in standard factory building practices and a preliminary assessment suggested that even at this early stage the technology is attractive when viewed from a life cycle cost perspective.« less

  11. The Production Data Approach for Full Lifecycle Management

    NASA Astrophysics Data System (ADS)

    Schopf, J.

    2012-04-01

    The amount of data generated by scientists is growing exponentially, and studies have shown [Koe04] that un-archived data sets have a resource half-life that is only a fraction of those resources that are electronically archived. Most groups still lack standard approaches and procedures for data management. Arguably, however, scientists know something about building software. A recent article in Nature [Mer10] stated that 45% of research scientists spend more time now developing software than they did 5 years ago, and 38% spent at least 1/5th of their time developing software. Fox argues [Fox10] that a simple release of data is not the correct approach to data curation. In addition, just as software is used in a wide variety of ways never initially envisioned by its developers, we're seeing this even to a greater extent with data sets. In order to address the need for better data preservation and access, we propose that data sets should be managed in a similar fashion to building production quality software. These production data sets are not simply published once, but go through a cyclical process, including phases such as design, development, verification, deployment, support, analysis, and then development again, thereby supporting the full lifecycle of a data set. The process involved in academically-produced software changes over time with respect to issues such as how much it is used outside the development group, but factors in aspects such as knowing who is using the code, enabling multiple developers to contribute to code development with common procedures, formal testing and release processes, developing documentation, and licensing. When we work with data, either as a collection source, as someone tagging data, or someone re-using it, many of the lessons learned in building production software are applicable. Table 1 shows a comparison of production software elements to production data elements. Table 1: Comparison of production software and production data. Production Software Production Data End-user considerations End-user considerations Multiple Coders: Repository with check-in procedures Coding standards Multiple producers/collectors Local archive with check-in procedure Metadata Standards Formal testing Formal testing Bug tracking and fixes Bug tracking and fixes, QA/QC Documentation Documentation Formal Release Process Formal release process to external archive License Citation/usage statement The full presentation of this abstract will include a detailed discussion of these issues so that researchers can produce usable and accessible data sets as a first step toward reproducible science. By creating production-quality data sets, we extend the potential of our data, both in terms of usability and usefulness to ourselves and other researchers. The more we treat data with formal processes and release cycles, the more relevant and useful it can be to the scientific community.

  12. LLNL NESHAPs 2015 Annual Report - June 2016

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, K. R.; Gallegos, G. M.; MacQueen, D. H.

    2016-06-01

    Lawrence Livermore National Security, LLC operates facilities at Lawrence Livermore National Laboratory (LLNL) in which radionuclides are handled and stored. These facilities are subject to the U.S. Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAPs) in Code of Federal Regulations (CFR) Title 40, Part 61, Subpart H, which regulates radionuclide emissions to air from Department of Energy (DOE) facilities. Specifically, NESHAPs limits the emission of radionuclides to the ambient air to levels resulting in an annual effective dose equivalent of 10 mrem (100 μSv) to any member of the public. Using measured and calculated emissions, andmore » building-specific and common parameters, LLNL personnel applied the EPA-approved computer code, CAP88-PC, Version 4.0.1.17, to calculate the dose to the maximally exposed individual member of the public for the Livermore Site and Site 300.« less

  13. 76 FR 42688 - Updating State Residential Building Energy Efficiency Codes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-19

    ... 19, 2013. ADDRESSES: Certification Statements must be addressed to the Buildings Technologies Program...-rise (greater than three stories) multifamily residential buildings and hotel, motel, and other..., townhouses, row houses, and low-rise multifamily buildings (not greater than three stories) such as...

  14. Beyond terrestrial biology: charting the chemical universe of α-amino acid structures.

    PubMed

    Meringer, Markus; Cleaves, H James; Freeland, Stephen J

    2013-11-25

    α-Amino acids are fundamental to biochemistry as the monomeric building blocks with which cells construct proteins according to genetic instructions. However, the 20 amino acids of the standard genetic code represent a tiny fraction of the number of α-amino acid chemical structures that could plausibly play such a role, both from the perspective of natural processes by which life emerged and evolved, and from the perspective of human-engineered genetically coded proteins. Until now, efforts to describe the structures comprising this broader set, or even estimate their number, have been hampered by the complex combinatorial properties of organic molecules. Here, we use computer software based on graph theory and constructive combinatorics in order to conduct an efficient and exhaustive search of the chemical structures implied by two careful and precise definitions of the α-amino acids relevant to coded biological proteins. Our results include two virtual libraries of α-amino acid structures corresponding to these different approaches, comprising 121 044 and 3 846 structures, respectively, and suggest a simple approach to exploring much larger, as yet uncomputed, libraries of interest.

  15. Representing nursing assessments in clinical information systems using the logical observation identifiers, names, and codes database.

    PubMed

    Matney, Susan; Bakken, Suzanne; Huff, Stanley M

    2003-01-01

    In recent years, the Logical Observation Identifiers, Names, and Codes (LOINC) Database has been expanded to include assessment items of relevance to nursing and in 2002 met the criteria for "recognition" by the American Nurses Association. Assessment measures in LOINC include those related to vital signs, obstetric measurements, clinical assessment scales, assessments from standardized nursing terminologies, and research instruments. In order for LOINC to be of greater use in implementing information systems that support nursing practice, additional content is needed. Moreover, those implementing systems for nursing practice must be aware of the manner in which LOINC codes for assessments can be appropriately linked with other aspects of the nursing process such as diagnoses and interventions. Such linkages are necessary to document nursing contributions to healthcare outcomes within the context of a multidisciplinary care environment and to facilitate building of nursing knowledge from clinical practice. The purposes of this paper are to provide an overview of the LOINC database, to describe examples of assessments of relevance to nursing contained in LOINC, and to illustrate linkages of LOINC assessments with other nursing concepts.

  16. 49 CFR Appendix C to Part 215 - FRA Freight Car Standards Defect Code

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false FRA Freight Car Standards Defect Code C Appendix C... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD FREIGHT CAR SAFETY STANDARDS Pt. 215, App. C Appendix C to Part 215—FRA Freight Car Standards Defect Code The following defect code has been established for use...

  17. 49 CFR Appendix C to Part 215 - FRA Freight Car Standards Defect Code

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false FRA Freight Car Standards Defect Code C Appendix C... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD FREIGHT CAR SAFETY STANDARDS Pt. 215, App. C Appendix C to Part 215—FRA Freight Car Standards Defect Code The following defect code has been established for use...

  18. 49 CFR Appendix C to Part 215 - FRA Freight Car Standards Defect Code

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false FRA Freight Car Standards Defect Code C Appendix C... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD FREIGHT CAR SAFETY STANDARDS Pt. 215, App. C Appendix C to Part 215—FRA Freight Car Standards Defect Code The following defect code has been established for use...

  19. 49 CFR Appendix C to Part 215 - FRA Freight Car Standards Defect Code

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false FRA Freight Car Standards Defect Code C Appendix C... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION RAILROAD FREIGHT CAR SAFETY STANDARDS Pt. 215, App. C Appendix C to Part 215—FRA Freight Car Standards Defect Code The following defect code has been established for use...

  20. Dynamic Geospatial Modeling of the Building Stock to Project Urban Energy Demand.

    PubMed

    Breunig, Hanna Marie; Huntington, Tyler; Jin, Ling; Robinson, Alastair; Scown, Corinne Donahue

    2018-06-26

    In the United States, buildings account for more than 40 percent of total energy consumption, and the evolution of the urban form will impact the effectiveness of strategies to reduce energy use and mitigate emissions. This paper presents a broadly applicable approach for modeling future commercial, residential, and industrial floorspace, thermal consumption (heating and cooling), and associated GHG emissions at the tax assessor land parcel level. The approach accounts for changing building standards and retrofitting, climate change, and trends in housing and industry. We demonstrate the automated workflow for California, and project building stock, thermal energy consumption, and associated GHG emissions out to 2050. Our results suggest that if buildings in California have long lifespans, and minimal energy efficiency improvements compared to building codes reflective of 2008, then the state will face a 20% or higher increase in thermal energy consumption by 2050. Baseline annual GHG emissions associated with thermal energy consumption in the modeled building stock in 2016 is 34% below 1990 levels (110 Mt CO2eq/y).While the 2020 targets for the reduction of GHG emissions set by the California Senate Bill 350 have already been met, none of our scenarios achieve >80% reduction from 1990 levels by 2050, despite assuming an 86% reduction in electricity carbon intensity in our "Low Carbon" scenario. The results highlight the challenge California faces in meeting its new energy efficiency targets unless the State's building stock undergoes timely and strategic turnover, paired with deep retrofitting of existing buildings and natural gas equipment.

  1. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 1 2013-07-01 2013-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  2. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 28 Judicial Administration 1 2014-07-01 2014-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  3. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 28 Judicial Administration 1 2012-07-01 2012-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  4. 28 CFR 36.607 - Guidance concerning model codes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 28 Judicial Administration 1 2011-07-01 2011-07-01 false Guidance concerning model codes. 36.607... BY PUBLIC ACCOMMODATIONS AND IN COMMERCIAL FACILITIES Certification of State Laws or Local Building Codes § 36.607 Guidance concerning model codes. Upon application by an authorized representative of a...

  5. Searching for Physics Beyond the Standard Model: Strongly-Coupled Field Theories at the Intensity and Energy Frontiers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brower, Richard C.

    This proposal is to develop the software and algorithmic infrastructure needed for the numerical study of quantum chromodynamics (QCD), and of theories that have been proposed to describe physics beyond the Standard Model (BSM) of high energy physics, on current and future computers. This infrastructure will enable users (1) to improve the accuracy of QCD calculations to the point where they no longer limit what can be learned from high-precision experiments that seek to test the Standard Model, and (2) to determine the predictions of BSM theories in order to understand which of them are consistent with the data thatmore » will soon be available from the LHC. Work will include the extension and optimizations of community codes for the next generation of leadership class computers, the IBM Blue Gene/Q and the Cray XE/XK, and for the dedicated hardware funded for our field by the Department of Energy. Members of our collaboration at Brookhaven National Laboratory and Columbia University worked on the design of the Blue Gene/Q, and have begun to develop software for it. Under this grant we will build upon their experience to produce high-efficiency production codes for this machine. Cray XE/XK computers with many thousands of GPU accelerators will soon be available, and the dedicated commodity clusters we obtain with DOE funding include growing numbers of GPUs. We will work with our partners in NVIDIA's Emerging Technology group to scale our existing software to thousands of GPUs, and to produce highly efficient production codes for these machines. Work under this grant will also include the development of new algorithms for the effective use of heterogeneous computers, and their integration into our codes. It will include improvements of Krylov solvers and the development of new multigrid methods in collaboration with members of the FASTMath SciDAC Institute, using their HYPRE framework, as well as work on improved symplectic integrators.« less

  6. Using safety inspection data to estimate shaking intensity for the 1994 Northridge earthquake

    USGS Publications Warehouse

    Thywissen, K.; Boatwright, J.

    1998-01-01

    We map the shaking intensity suffered in Los Angeles County during the 17 January 1994, Northridge earthquake using municipal safety inspection data. The intensity is estimated from the number of buildings given red, yellow, or green tags, aggregated by census tract. Census tracts contain from 200 to 4000 residential buildings and have an average area of 6 km2 but are as small as 2 and 1 km2 in the most densely populated areas of the San Fernando Valley and downtown Los Angeles, respectively. In comparison, the zip code areas on which standard MMI intensity estimates are based are six times larger, on average, than the census tracts. We group the buildings by age (before and after 1940 and 1976), by number of housing units (one, two to four, and five or more), and by construction type, and we normalize the tags by the total number of similar buildings in each census tract. We analyze the seven most abundant building categories. The fragilities (the fraction of buildings in each category tagged within each intensity level) for these seven building categories are adjusted so that the intensity estimates agree. We calibrate the shaking intensity to correspond with the modified Mercalli intensities (MMI) estimated and compiled by Dewey et al. (1995); the shapes of the resulting isoseismals are similar, although we underestimate the extent of the MMI = 6 and 7 areas. The fragility varies significantly between different building categories (by factors of 10 to 20) and building ages (by factors of 2 to 6). The post-1940 wood-frame multi-family (???5 units) dwellings make up the most fragile building category, and the post-1940 wood-frame single-family dwellings make up the most resistant building category.

  7. RESRAD model presentation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, C.; Faillace, E.; Chen, S.Y.

    RESRAD was one of the multimedia models selected by the US Nuclear Regulatory Commission (NRC) to include in its workshop on radiation dose modeling and demonstration of compliance with the radiological criteria for license termination. This paper is a summary of the presentation made at the workshop and focuses on the 10 questions the NRC distributed to all participants prior to the workshop. The code selection criteria, which were solicited by the NRC, for demonstrating compliance with the license termination rule are also included. Among the RESRAD family of codes, RESRAD and RESRAD-BUILD are designed for evaluating radiological contamination inmore » soils and in buildings. Many documents have been published to support the use of these codes. This paper focuses on these two codes. The pathways considered, the databases and parameters used, quality control and quality assurance, benchmarking, verification and validation of these codes, and capabilities as well as limitations of these codes are discussed in detail.« less

  8. Methodology for the preliminary design of high performance schools in hot and humid climates

    NASA Astrophysics Data System (ADS)

    Im, Piljae

    A methodology to develop an easy-to-use toolkit for the preliminary design of high performance schools in hot and humid climates was presented. The toolkit proposed in this research will allow decision makers without simulation knowledge easily to evaluate accurately energy efficient measures for K-5 schools, which would contribute to the accelerated dissemination of energy efficient design. For the development of the toolkit, first, a survey was performed to identify high performance measures available today being implemented in new K-5 school buildings. Then an existing case-study school building in a hot and humid climate was selected and analyzed to understand the energy use pattern in a school building and to be used in developing a calibrated simulation. Based on the information from the previous step, an as-built and calibrated simulation was then developed. To accomplish this, five calibration steps were performed to match the simulation results with the measured energy use. The five steps include: (1) Using an actual 2006 weather file with measured solar radiation, (2) Modifying lighting & equipment schedule using ASHRAE's RP-1093 methods, (3) Using actual equipment performance curves (i.e., scroll chiller), (4) Using the Winkelmann's method for the underground floor heat transfer, and (5) Modifying the HVAC and room setpoint temperature based on the measured field data. Next, the calibrated simulation of the case-study K-5 school was compared to an ASHRAE Standard 90.1-1999 code-compliant school. In the next step, the energy savings potentials from the application of several high performance measures to an equivalent ASHRAE Standard 90.1-1999 code-compliant school. The high performance measures applied included the recommendations from the ASHRAE Advanced Energy Design Guides (AEDG) for K-12 and other high performance measures from the literature review as well as a daylighting strategy and solar PV and thermal systems. The results show that the net energy consumption of the final high performance school with the solar thermal and a solar PV system would be 1,162.1 MMBtu, which corresponds to the 14.9 kBtu/sqft-yr of EUI. The calculated final energy and cost savings over the code compliant school are 68.2% and 69.9%, respectively. As a final step of the research, specifications for a simplified easy-to-use toolkit were then developed, and a prototype screenshot of the toolkit was developed. The toolkit is expected to be used by non-technical decision-maker to select and evaluate high performance measures for a new school building in terms of energy and cost savings in a quick and easy way.

  9. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  10. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 3 2014-01-01 2014-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  11. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 3 2012-01-01 2012-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  12. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 3 2013-01-01 2013-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  13. 10 CFR 434.503 - Prototype building procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Prototype building procedure. 434.503 Section 434.503 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.503 Prototype...

  14. Ethical Guidelines for Structural Interventions to Small-Scale Historic Stone Masonry Buildings.

    PubMed

    Hurol, Yonca; Yüceer, Hülya; Başarır, Hacer

    2015-12-01

    Structural interventions to historic stone masonry buildings require that both structural and heritage values be considered simultaneously. The absence of one of these value systems in implementation can be regarded as an unethical professional action. The research objective of this article is to prepare a guideline for ensuring ethical structural interventions to small-scale stone historic masonry buildings in the conservation areas of Northern Cyprus. The methodology covers an analysis of internationally accepted conservation documents and national laws related to the conservation of historic buildings, an analysis of building codes, especially Turkish building codes, which have been used in Northern Cyprus, and an analysis of the structural interventions introduced to a significant historic building in a semi-intact state in the walled city of Famagusta. This guideline covers issues related to whether buildings are intact or ruined, the presence of earthquake risk, the types of structural decisions in an architectural conservation project, and the values to consider during the decision making phase.

  15. Application of LEED (trademark) and SPiRiT to a Proposed Building Design

    DTIC Science & Technology

    2003-03-01

    TOTAL AREA S CAT ARLOC INSTALLATION NO CODE C QTY UM OCPD F CODE 1) 24004 Aberdeen Provi E1890...ARLOC INSTALLATION NO CODE C QTY UM OCPD F CODE 1) 24004 Aberdeen Provi E3832 31010 P 13,000 SF 13,000 R

  16. Evaluating the benefits of commercial building energy codes and improving federal incentives for code adoption.

    PubMed

    Gilbraith, Nathaniel; Azevedo, Inês L; Jaramillo, Paulina

    2014-12-16

    The federal government has the goal of decreasing commercial building energy consumption and pollutant emissions by incentivizing the adoption of commercial building energy codes. Quantitative estimates of code benefits at the state level that can inform the size and allocation of these incentives are not available. We estimate the state-level climate, environmental, and health benefits (i.e., social benefits) and reductions in energy bills (private benefits) of a more stringent code (ASHRAE 90.1-2010) relative to a baseline code (ASHRAE 90.1-2007). We find that reductions in site energy use intensity range from 93 MJ/m(2) of new construction per year (California) to 270 MJ/m(2) of new construction per year (North Dakota). Total annual benefits from more stringent codes total $506 million for all states, where $372 million are from reductions in energy bills, and $134 million are from social benefits. These total benefits range from $0.6 million in Wyoming to $49 million in Texas. Private benefits range from $0.38 per square meter in Washington State to $1.06 per square meter in New Hampshire. Social benefits range from $0.2 per square meter annually in California to $2.5 per square meter in Ohio. Reductions in human/environmental damages and future climate damages account for nearly equal shares of social benefits.

  17. Residential building codes, affordability, and health protection: a risk-tradeoff approach.

    PubMed

    Hammitt, J K; Belsky, E S; Levy, J I; Graham, J D

    1999-12-01

    Residential building codes intended to promote health and safety may produce unintended countervailing risks by adding to the cost of construction. Higher construction costs increase the price of new homes and may increase health and safety risks through "income" and "stock" effects. The income effect arises because households that purchase a new home have less income remaining for spending on other goods that contribute to health and safety. The stock effect arises because suppression of new-home construction leads to slower replacement of less safe housing units. These countervailing risks are not presently considered in code debates. We demonstrate the feasibility of estimating the approximate magnitude of countervailing risks by combining the income effect with three relatively well understood and significant home-health risks. We estimate that a code change that increases the nationwide cost of constructing and maintaining homes by $150 (0.1% of the average cost to build a single-family home) would induce offsetting risks yielding between 2 and 60 premature fatalities or, including morbidity effects, between 20 and 800 lost quality-adjusted life years (both discounted at 3%) each year the code provision remains in effect. To provide a net health benefit, the code change would need to reduce risk by at least this amount. Future research should refine these estimates, incorporate quantitative uncertainty analysis, and apply a full risk-tradeoff approach to real-world case studies of proposed code changes.

  18. Two Perspectives on the Origin of the Standard Genetic Code

    NASA Astrophysics Data System (ADS)

    Sengupta, Supratim; Aggarwal, Neha; Bandhu, Ashutosh Vishwa

    2014-12-01

    The origin of a genetic code made it possible to create ordered sequences of amino acids. In this article we provide two perspectives on code origin by carrying out simulations of code-sequence coevolution in finite populations with the aim of examining how the standard genetic code may have evolved from more primitive code(s) encoding a small number of amino acids. We determine the efficacy of the physico-chemical hypothesis of code origin in the absence and presence of horizontal gene transfer (HGT) by allowing a diverse collection of code-sequence sets to compete with each other. We find that in the absence of horizontal gene transfer, natural selection between competing codes distinguished by differences in the degree of physico-chemical optimization is unable to explain the structure of the standard genetic code. However, for certain probabilities of the horizontal transfer events, a universal code emerges having a structure that is consistent with the standard genetic code.

  19. The taxonomic name resolution service: an online tool for automated standardization of plant names

    PubMed Central

    2013-01-01

    Background The digitization of biodiversity data is leading to the widespread application of taxon names that are superfluous, ambiguous or incorrect, resulting in mismatched records and inflated species numbers. The ultimate consequences of misspelled names and bad taxonomy are erroneous scientific conclusions and faulty policy decisions. The lack of tools for correcting this ‘names problem’ has become a fundamental obstacle to integrating disparate data sources and advancing the progress of biodiversity science. Results The TNRS, or Taxonomic Name Resolution Service, is an online application for automated and user-supervised standardization of plant scientific names. The TNRS builds upon and extends existing open-source applications for name parsing and fuzzy matching. Names are standardized against multiple reference taxonomies, including the Missouri Botanical Garden's Tropicos database. Capable of processing thousands of names in a single operation, the TNRS parses and corrects misspelled names and authorities, standardizes variant spellings, and converts nomenclatural synonyms to accepted names. Family names can be included to increase match accuracy and resolve many types of homonyms. Partial matching of higher taxa combined with extraction of annotations, accession numbers and morphospecies allows the TNRS to standardize taxonomy across a broad range of active and legacy datasets. Conclusions We show how the TNRS can resolve many forms of taxonomic semantic heterogeneity, correct spelling errors and eliminate spurious names. As a result, the TNRS can aid the integration of disparate biological datasets. Although the TNRS was developed to aid in standardizing plant names, its underlying algorithms and design can be extended to all organisms and nomenclatural codes. The TNRS is accessible via a web interface at http://tnrs.iplantcollaborative.org/ and as a RESTful web service and application programming interface. Source code is available at https://github.com/iPlantCollaborativeOpenSource/TNRS/. PMID:23324024

  20. Mobius Assembly: A versatile Golden-Gate framework towards universal DNA assembly.

    PubMed

    Andreou, Andreas I; Nakayama, Naomi

    2018-01-01

    Synthetic biology builds upon the foundation of engineering principles, prompting innovation and improvement in biotechnology via a design-build-test-learn cycle. A community-wide standard in DNA assembly would enable bio-molecular engineering at the levels of predictivity and universality in design and construction that are comparable to other engineering fields. Golden Gate Assembly technology, with its robust capability to unidirectionally assemble numerous DNA fragments in a one-tube reaction, has the potential to deliver a universal standard framework for DNA assembly. While current Golden Gate Assembly frameworks (e.g. MoClo and Golden Braid) render either high cloning capacity or vector toolkit simplicity, the technology can be made more versatile-simple, streamlined, and cost/labor-efficient, without compromising capacity. Here we report the development of a new Golden Gate Assembly framework named Mobius Assembly, which combines vector toolkit simplicity with high cloning capacity. It is based on a two-level, hierarchical approach and utilizes a low-frequency cutter to reduce domestication requirements. Mobius Assembly embraces the standard overhang designs designated by MoClo, Golden Braid, and Phytobricks and is largely compatible with already available Golden Gate part libraries. In addition, dropout cassettes encoding chromogenic proteins were implemented for cost-free visible cloning screening that color-code different cloning levels. As proofs of concept, we have successfully assembled up to 16 transcriptional units of various pigmentation genes in both operon and multigene arrangements. Taken together, Mobius Assembly delivers enhanced versatility and efficiency in DNA assembly, facilitating improved standardization and automation.

  1. Rethinking ADA signage standards for low-vision accessibility.

    PubMed

    Arditi, Aries

    2017-05-01

    Americans With Disabilities Act (ADA) and International Code Council (ICC) standards for accessible buildings and facilities affect design and construction of all new and renovated buildings throughout the United States, and form the basis for compliance with the ADA. While these standards may result in acceptable accessibility for people who are fully blind, they fall far short of what they could and should accomplish for those with low vision. In this article I critique the standards, detailing their lack of evidence base and other shortcomings. I suggest that simply making existing requirements stricter (e.g., by mandating larger letter size or higher contrasts) will not ensure visual accessibility and therefore cannot act as a valid basis for compliance with the law. I propose two remedies. First, requirements for visual characteristics of signs intended to improve access for those with low vision should be expressed not in terms of physical features, such as character height and contrast, but rather in terms of the distance at which a sign can be read by someone with nominally normal (20/20) visual acuity under expected lighting conditions for the installed environment. This would give sign designers greater choice in design parameters but place on them the burden of ensuring legibility. Second, mounting of directional signs, which are critical for effective and efficient wayfinding, should be required to be in consistent and approachable locations so that those with reduced acuity may view them at close distance.

  2. Rethinking ADA signage standards for low-vision accessibility

    PubMed Central

    Arditi, Aries

    2017-01-01

    Americans With Disabilities Act (ADA) and International Code Council (ICC) standards for accessible buildings and facilities affect design and construction of all new and renovated buildings throughout the United States, and form the basis for compliance with the ADA. While these standards may result in acceptable accessibility for people who are fully blind, they fall far short of what they could and should accomplish for those with low vision. In this article I critique the standards, detailing their lack of evidence base and other shortcomings. I suggest that simply making existing requirements stricter (e.g., by mandating larger letter size or higher contrasts) will not ensure visual accessibility and therefore cannot act as a valid basis for compliance with the law. I propose two remedies. First, requirements for visual characteristics of signs intended to improve access for those with low vision should be expressed not in terms of physical features, such as character height and contrast, but rather in terms of the distance at which a sign can be read by someone with nominally normal (20/20) visual acuity under expected lighting conditions for the installed environment. This would give sign designers greater choice in design parameters but place on them the burden of ensuring legibility. Second, mounting of directional signs, which are critical for effective and efficient wayfinding, should be required to be in consistent and approachable locations so that those with reduced acuity may view them at close distance. PMID:28510625

  3. Technical Support Document for Version 3.6.1 of the COMcheck Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bartlett, Rosemarie; Connell, Linda M.; Gowri, Krishnan

    2009-09-29

    This technical support document (TSD) is designed to explain the technical basis for the COMcheck software as originally developed based on the ANSI/ASHRAE/IES Standard 90.1-1989 (Standard 90.1-1989). Documentation for other national model codes and standards and specific state energy codes supported in COMcheck has been added to this report as appendices. These appendices are intended to provide technical documentation for features specific to the supported codes and for any changes made for state-specific codes that differ from the standard features that support compliance with the national model codes and standards.

  4. Sandia National Laboratories Facilities Management and Operations Center Design Standards Manual

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peterson, Timothy L.

    2014-09-01

    At Sandia National Laboratories in New Mexico (SNL/NM), the design, construction, operation, and maintenance of facilities is guided by industry standards, a graded approach, and the systematic analysis of life cycle benefits received for costs incurred. The design of the physical plant must ensure that the facilities are "fit for use," and provide conditions that effectively, efficiently, and safely support current and future mission needs. In addition, SNL/NM applies sustainable design principles, using an integrated whole-building design approach, from site planning to facility design, construction, and operation to ensure building resource efficiency and the health and productivity of occupants. Themore » safety and health of the workforce and the public, any possible effects on the environment, and compliance with building codes take precedence over project issues, such as performance, cost, and schedule. These design standards generally apply to all disciplines on all SNL/NM projects. Architectural and engineering design must be both functional and cost-effective. Facility design must be tailored to fit its intended function, while emphasizing low-maintenance, energy-efficient, and energy-conscious design. Design facilities that can be maintained easily, with readily accessible equipment areas, low maintenance, and quality systems. To promote an orderly and efficient appearance, architectural features of new facilities must complement and enhance the existing architecture at the site. As an Architectural and Engineering (A/E) professional, you must advise the Project Manager when this approach is prohibitively expensive. You are encouraged to use professional judgment and ingenuity to produce a coordinated interdisciplinary design that is cost-effective, easily contractible or buildable, high-performing, aesthetically pleasing, and compliant with applicable building codes. Close coordination and development of civil, landscape, structural, architectural, fire protection, mechanical, electrical, telecommunications, and security features is expected to ensure compatibility with planned functional equipment and to facilitate constructability. If portions of the design are subcontracted to specialists, delivery of the finished design documents must not be considered complete until the subcontracted portions are also submitted for review. You must, along with support consultants, perform functional analyses and programming in developing design solutions. These solutions must reflect coordination of the competing functional, budgetary, and physical requirements for the project. During design phases, meetings between you and the SNL/NM Project Team to discuss and resolve design issues are required. These meetings are a normal part of the design process. For specific design-review requirements, see the project-specific Design Criteria. In addition to the design requirements described in this manual, instructive information is provided to explain the sustainable building practice goals for design, construction, operation, and maintenance of SNL/NM facilities. Please notify SNL/NM personnel of design best practices not included in this manual, so they can be incorporated in future updates. You must convey all documents describing work to the SNL/NM Project Manager in both hard copy and in an electronic format compatible with the SNL/NM-prescribed CADD and other software packages, and in accordance with a SNL/NM approved standard format. Print all hard copy versions of submitted documents (excluding drawings and renderings) double-sided when practical.« less

  5. 24 CFR 242.78 - Zoning, deed, and building restrictions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Zoning, deed, and building... AUTHORITIES MORTGAGE INSURANCE FOR HOSPITALS Miscellaneous Requirements § 242.78 Zoning, deed, and building... to the project site, and shall comply with all applicable building and other governmental codes...

  6. Feedback Codes and Action Plans: Building the Capacity of First-Year Students to Apply Feedback to a Scientific Report

    ERIC Educational Resources Information Center

    Bird, Fiona L.; Yucel, Robyn

    2015-01-01

    Effective feedback can build self-assessment skills in students so that they become more competent and confident to identify and self-correct weaknesses in their work. In this study, we trialled a feedback code as part of an integrated programme of formative and summative assessment tasks, which provided feedback to first-year students on their…

  7. Searching for Planning and Design Solutions.

    ERIC Educational Resources Information Center

    Roark, Steven

    2001-01-01

    Presents the fourth article in a series on the Longview Community College (Kansas City, Missouri) Liberal Arts building project. How architects are revising floor plans, evaluating building systems, deciding on furniture, and dealing with building codes are discussed. (GR)

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dillon, Heather E.; Antonopoulos, Chrissi A.; Solana, Amy E.

    As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density permore » unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft{sup 2} of roof area or 0.5 W/ft{sup 2} of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft{sup 2} of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.« less

  9. Using Third-Party Inspectors in Building Energy Codes Enforcement in India

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yu, Sha; Evans, Meredydd; Kumar, Pradeep

    India is experiencing fast income growth and urbanization, and this leads to unprecedented increases in demand for building energy services and resulting energy consumption. In response to rapid growth in building energy use, the Government of India issued the Energy Conservation Building Code (ECBC) in 2007, which is consistent with and based on the 2001 Energy Conservation Act. ECBC implementation has been voluntary since its enactment and a few states have started to make progress towards mandatory implementation. Rajasthan is the first state in India to adopt ECBC as a mandatory code. The State adopted ECBC with minor additions onmore » March 28, 2011 through a stakeholder process; it became mandatory in Rajasthan on September 28, 2011. Tamil Nadu, Gujarat, and Andhra Pradesh have started to draft an implementation roadmap and build capacity for its implementation. The Bureau of Energy Efficiency (BEE) plans to encourage more states to adopt ECBC in the near future, including Haryana, Uttar Pradesh, Karnataka, Maharashtra, West Bengal, and Delhi. Since its inception, India has applied the code on a voluntary basis, but the Government of India is developing a strategy to mandate compliance. Implementing ECBC requires coordination between the Ministry of Power and the Ministry of Urban Development at the national level as well as interdepartmental coordination at the state level. One challenge is that the Urban Local Bodies (ULBs), the enforcement entities of building by-laws, lack capacity to implement ECBC effectively. For example, ULBs in some states might find the building permitting procedures to be too complex; in other cases, lack of awareness and technical knowledge on ECBC slows down the amendment of local building by-laws as well as ECBC implementation. The intent of this white paper is to share with Indian decision-makers code enforcement approaches: through code officials, third-party inspectors, or a hybrid approach. Given the limited capacity and human resources available in the state and local governments, involving third-party inspectors could rapidly expand the capacity for plan reviews and broad implementation. However, the procedures of involving third-parties need to be carefully designed in order to guarantee a fair process. For example, there should be multiple checks and certification requirements for third-party inspectors, and the government should have the final approval when third-party inspectors are used in a project. This paper discusses different approaches of involving third-parties in ECBC enforcement; the Indian states may choose the approaches that work best in their given circumstances.« less

  10. ATLAS software configuration and build tool optimisation

    NASA Astrophysics Data System (ADS)

    Rybkin, Grigory; Atlas Collaboration

    2014-06-01

    ATLAS software code base is over 6 million lines organised in about 2000 packages. It makes use of some 100 external software packages, is developed by more than 400 developers and used by more than 2500 physicists from over 200 universities and laboratories in 6 continents. To meet the challenge of configuration and building of this software, the Configuration Management Tool (CMT) is used. CMT expects each package to describe its build targets, build and environment setup parameters, dependencies on other packages in a text file called requirements, and each project (group of packages) to describe its policies and dependencies on other projects in a text project file. Based on the effective set of configuration parameters read from the requirements files of dependent packages and project files, CMT commands build the packages, generate the environment for their use, or query the packages. The main focus was on build time performance that was optimised within several approaches: reduction of the number of reads of requirements files that are now read once per package by a CMT build command that generates cached requirements files for subsequent CMT build commands; introduction of more fine-grained build parallelism at package task level, i.e., dependent applications and libraries are compiled in parallel; code optimisation of CMT commands used for build; introduction of package level build parallelism, i. e., parallelise the build of independent packages. By default, CMT launches NUMBER-OF-PROCESSORS build commands in parallel. The other focus was on CMT commands optimisation in general that made them approximately 2 times faster. CMT can generate a cached requirements file for the environment setup command, which is especially useful for deployment on distributed file systems like AFS or CERN VMFS. The use of parallelism, caching and code optimisation significantly-by several times-reduced software build time, environment setup time, increased the efficiency of multi-core computing resources utilisation, and considerably improved software developer and user experience.

  11. PUS Services Software Building Block Automatic Generation for Space Missions

    NASA Astrophysics Data System (ADS)

    Candia, S.; Sgaramella, F.; Mele, G.

    2008-08-01

    The Packet Utilization Standard (PUS) has been specified by the European Committee for Space Standardization (ECSS) and issued as ECSS-E-70-41A to define the application-level interface between Ground Segments and Space Segments. The ECSS-E- 70-41A complements the ECSS-E-50 and the Consultative Committee for Space Data Systems (CCSDS) recommendations for packet telemetry and telecommand. The ECSS-E-70-41A characterizes the identified PUS Services from a functional point of view and the ECSS-E-70-31 standard specifies the rules for their mission-specific tailoring. The current on-board software design for a space mission implies the production of several PUS terminals, each providing a specific tailoring of the PUS services. The associated on-board software building blocks are developed independently, leading to very different design choices and implementations even when the mission tailoring requires very similar services (from the Ground operative perspective). In this scenario, the automatic production of the PUS services building blocks for a mission would be a way to optimize the overall mission economy and improve the robusteness and reliability of the on-board software and of the Ground-Space interactions. This paper presents the Space Software Italia (SSI) activities for the development of an integrated environment to support: the PUS services tailoring activity for a specific mission. the mission-specific PUS services configuration. the generation the UML model of the software building block implementing the mission-specific PUS services and the related source code, support documentation (software requirements, software architecture, test plans/procedures, operational manuals), and the TM/TC database. The paper deals with: (a) the project objectives, (b) the tailoring, configuration, and generation process, (c) the description of the environments supporting the process phases, (d) the characterization of the meta-model used for the generation, (e) the characterization of the reference avionics architecture and of the reference on- board software high-level architecture.

  12. The proposed coding standard at GSFC

    NASA Technical Reports Server (NTRS)

    Morakis, J. C.; Helgert, H. J.

    1977-01-01

    As part of the continuing effort to introduce standardization of spacecraft and ground equipment in satellite systems, NASA's Goddard Space Flight Center and other NASA facilities have supported the development of a set of standards for the use of error control coding in telemetry subsystems. These standards are intended to ensure compatibility between spacecraft and ground encoding equipment, while allowing sufficient flexibility to meet all anticipated mission requirements. The standards which have been developed to date cover the application of block codes in error detection and error correction modes, as well as short and long constraint length convolutional codes decoded via the Viterbi and sequential decoding algorithms, respectively. Included are detailed specifications of the codes, and their implementation. Current effort is directed toward the development of standards covering channels with burst noise characteristics, channels with feedback, and code concatenation.

  13. Verification of BWR Turbine Skyshine Dose with the MCNP5 Code Based on an Experiment Made at SHIMANE Nuclear Power Station

    NASA Astrophysics Data System (ADS)

    Tayama, Ryuichi; Wakasugi, Kenichi; Kawanaka, Ikunori; Kadota, Yoshinobu; Murakami, Yasuhiro

    We measured the skyshine dose from turbine buildings at Shimane Nuclear Power Station Unit 1 (NS-1) and Unit 2 (NS-2), and then compared it with the dose calculated with the Monte Carlo transport code MCNP5. The skyshine dose values calculated with the MCNP5 code agreed with the experimental data within a factor of 2.8, when the roof of the turbine building was precisely modeled. We concluded that our MCNP5 calculation was valid for BWR turbine skyshine dose evaluation.

  14. Soft-Input Soft-Output Modules for the Construction and Distributed Iterative Decoding of Code Networks

    NASA Technical Reports Server (NTRS)

    Benedetto, S.; Divsalar, D.; Montorsi, G.; Pollara, F.

    1998-01-01

    Soft-input soft-output building blocks (modules) are presented to construct and iteratively decode in a distributed fashion code networks, a new concept that includes, and generalizes, various forms of concatenated coding schemes.

  15. Sustainable regulation of construction.

    PubMed

    2000-11-01

    The seminar examined the role building codes and regulations can have in promoting a more sustainable approach to construction, particularly through their application to non-industrial building materials. A range of building materials such as straw, bamboo, rammed earth, adobe, and cob (a mixture of clay and chopped straw) were described and illustrated by slides to show their building potential. The current codes have a prime concern to protect the health and safety of people from the built environment. They have been developed almost exclusively for mainstream industrial materials and methods of construction, which makes them difficult to use with alternative, indigenous, or non-industrial building materials, even though those materials may be considered more sustainable. The argument was put forward that with only one-third of the world population living in modern industrial buildings today, it is not sustainable to re-house the remaining rapidly expanding population in high technology dwellings. Many of the low technology building materials and methods now used by the majority of people in the world need only incremental improvement to be equal or superior to many of their industrial replacements. Since these can be more sustainable methods of building, there needs to be an acceptance of the use of alternative materials, particularly in the developing parts of the world, where they are being rejected for less sustainable industrial methods. However, many codes make it difficult to use non-industrial materials; indeed, many of the industrial materials would not meet the demands that must be now met if they were now being introduced as new materials. Consequently, there is a need to develop codes to facilitate the use of a wider range of materials than in current use, and research is needed to assist this development. Sustainable regulation should take into account the full range of real impacts that materials and systems have in areas such as resource use and depletion, toxicity of the processes that produce them, and their potential for re-use and recyclability.

  16. 10 CFR 434.99 - Explanation of numbering system for codes.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 3 2011-01-01 2011-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...

  17. 10 CFR 434.99 - Explanation of numbering system for codes.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Explanation of numbering system for codes. 434.99 Section 434.99 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY CODE FOR NEW FEDERAL COMMERCIAL AND MULTI-FAMILY HIGH RISE RESIDENTIAL BUILDINGS § 434.99 Explanation of numbering system for codes. (a) For...

  18. Side-information-dependent correlation channel estimation in hash-based distributed video coding.

    PubMed

    Deligiannis, Nikos; Barbarien, Joeri; Jacobs, Marc; Munteanu, Adrian; Skodras, Athanassios; Schelkens, Peter

    2012-04-01

    In the context of low-cost video encoding, distributed video coding (DVC) has recently emerged as a potential candidate for uplink-oriented applications. This paper builds on a concept of correlation channel (CC) modeling, which expresses the correlation noise as being statistically dependent on the side information (SI). Compared with classical side-information-independent (SII) noise modeling adopted in current DVC solutions, it is theoretically proven that side-information-dependent (SID) modeling improves the Wyner-Ziv coding performance. Anchored in this finding, this paper proposes a novel algorithm for online estimation of the SID CC parameters based on already decoded information. The proposed algorithm enables bit-plane-by-bit-plane successive refinement of the channel estimation leading to progressively improved accuracy. Additionally, the proposed algorithm is included in a novel DVC architecture that employs a competitive hash-based motion estimation technique to generate high-quality SI at the decoder. Experimental results corroborate our theoretical gains and validate the accuracy of the channel estimation algorithm. The performance assessment of the proposed architecture shows remarkable and consistent coding gains over a germane group of state-of-the-art distributed and standard video codecs, even under strenuous conditions, i.e., large groups of pictures and highly irregular motion content.

  19. Development of an extensible dual-core wireless sensing node for cyber-physical systems

    NASA Astrophysics Data System (ADS)

    Kane, Michael; Zhu, Dapeng; Hirose, Mitsuhito; Dong, Xinjun; Winter, Benjamin; Häckell, Mortiz; Lynch, Jerome P.; Wang, Yang; Swartz, A.

    2014-04-01

    The introduction of wireless telemetry into the design of monitoring and control systems has been shown to reduce system costs while simplifying installations. To date, wireless nodes proposed for sensing and actuation in cyberphysical systems have been designed using microcontrollers with one computational pipeline (i.e., single-core microcontrollers). While concurrent code execution can be implemented on single-core microcontrollers, concurrency is emulated by splitting the pipeline's resources to support multiple threads of code execution. For many applications, this approach to multi-threading is acceptable in terms of speed and function. However, some applications such as feedback controls demand deterministic timing of code execution and maximum computational throughput. For these applications, the adoption of multi-core processor architectures represents one effective solution. Multi-core microcontrollers have multiple computational pipelines that can execute embedded code in parallel and can be interrupted independent of one another. In this study, a new wireless platform named Martlet is introduced with a dual-core microcontroller adopted in its design. The dual-core microcontroller design allows Martlet to dedicate one core to standard wireless sensor operations while the other core is reserved for embedded data processing and real-time feedback control law execution. Another distinct feature of Martlet is a standardized hardware interface that allows specialized daughter boards (termed wing boards) to be interfaced to the Martlet baseboard. This extensibility opens opportunity to encapsulate specialized sensing and actuation functions in a wing board without altering the design of Martlet. In addition to describing the design of Martlet, a few example wings are detailed, along with experiments showing the Martlet's ability to monitor and control physical systems such as wind turbines and buildings.

  20. Design pattern mining using distributed learning automata and DNA sequence alignment.

    PubMed

    Esmaeilpour, Mansour; Naderifar, Vahideh; Shukur, Zarina

    2014-01-01

    Over the last decade, design patterns have been used extensively to generate reusable solutions to frequently encountered problems in software engineering and object oriented programming. A design pattern is a repeatable software design solution that provides a template for solving various instances of a general problem. This paper describes a new method for pattern mining, isolating design patterns and relationship between them; and a related tool, DLA-DNA for all implemented pattern and all projects used for evaluation. DLA-DNA achieves acceptable precision and recall instead of other evaluated tools based on distributed learning automata (DLA) and deoxyribonucleic acid (DNA) sequences alignment. The proposed method mines structural design patterns in the object oriented source code and extracts the strong and weak relationships between them, enabling analyzers and programmers to determine the dependency rate of each object, component, and other section of the code for parameter passing and modular programming. The proposed model can detect design patterns better that available other tools those are Pinot, PTIDEJ and DPJF; and the strengths of their relationships. The result demonstrate that whenever the source code is build standard and non-standard, based on the design patterns, then the result of the proposed method is near to DPJF and better that Pinot and PTIDEJ. The proposed model is tested on the several source codes and is compared with other related models and available tools those the results show the precision and recall of the proposed method, averagely 20% and 9.6% are more than Pinot, 27% and 31% are more than PTIDEJ and 3.3% and 2% are more than DPJF respectively. The primary idea of the proposed method is organized in two following steps: the first step, elemental design patterns are identified, while at the second step, is composed to recognize actual design patterns.

Top